WorldWideScience

Sample records for normal radiographic heart

  1. Radiographic heart-volume estimation in normal cats

    International Nuclear Information System (INIS)

    Ahlberg, N.E.; Hansson, K.; Svensson, L.; Iwarsson, K.

    1989-01-01

    Heart volume mensuration was evaluated on conventional radiographs from eight normal cats in different body positions using computed tomography (CT). Heart volumes were calculated from orthogonal thoracic radiographs in ventral and dorsal recumbency and from radiographs exposed with a vertical X-ray beam in dorsal and lateral recumbency using the formula for an ellipsoid body. Heart volumes were also estimated with CT in ventral, dorsal, right lateral and left lateral recumbency. No differences between heart volumes from CT in ventral recumbency and those from CT in right and left lateral recumbency were seen. In dorsal recumbency, however, significantly lower heart volumes were obtained. Heart volumes from CT in ventral recumbency were similar to those from radiographs in ventral and dorsal recumbency and dorsal/left lateral recumbency. Close correlation was also demonstrated between heart volumes from radiographs in dorsal/ left lateral recumbency and body weights of the eight cats

  2. Normal radiographic heart volume in the neonate. Pt. 3

    International Nuclear Information System (INIS)

    Dahlstroem, A.; Ringertz, H.G.; Sachsska Pediatric Hospital, Stockholm

    1985-01-01

    The diagnostic power of the heart volume and the cardiothoracic ratio in congenital heart disease in neonates has been compared. A consecutive series of 130 children with suspection of heart disease examined radiologically at between 48 h and 15 days of age were followed for 14+-10 months. Of these, 16 (12%) were diagnosed as having congenital heart disease. The number of false positive and negative diagnoses was less for heart volume than for cardiothoracic ratio using +2 SD as limit for pathology. Accuracy, sensitivity and specificity was 84, 75, and 85% respectively for heart volume and 73, 57, and 75% for cardiothoracic ratio. Cases that were false positive with both methods were significantly more often examined between 48 and 72 hours of age indicating that the explanation might be a somewhat late closure of the ductus arteriosus. (orig.)

  3. Normal radiographic findings. 4. act. ed.

    International Nuclear Information System (INIS)

    Moeller, T.B.

    2003-01-01

    This book can serve the reader in three ways: First, it presents normal findings for all radiographic techniques including KM. Important data which are criteria of normal findings are indicated directly in the pictures and are also explained in full text and in summary form. Secondly, it teaches the systematics of interpreting a picture - how to look at it, what structures to regard in what order, and for what to look in particular. Checklists are presented in each case. Thirdly, findings are formulated in accordance with the image analysis procedure. All criteria of normal findings are defined in these formulations, which make them an important didactic element. (orig.)

  4. Normal radiographic findings. 4. act. ed.; Roentgennormalbefunde

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, T.B. [Gemeinschaftspraxis fuer Radiologie und Nuklearmedizin, Dillingen (Germany)

    2003-07-01

    This book can serve the reader in three ways: First, it presents normal findings for all radiographic techniques including KM. Important data which are criteria of normal findings are indicated directly in the pictures and are also explained in full text and in summary form. Secondly, it teaches the systematics of interpreting a picture - how to look at it, what structures to regard in what order, and for what to look in particular. Checklists are presented in each case. Thirdly, findings are formulated in accordance with the image analysis procedure. All criteria of normal findings are defined in these formulations, which make them an important didactic element. (orig.)

  5. Vertebral scale system to measure canine heart size in radiographs

    International Nuclear Information System (INIS)

    Buchanan, J.W.; Bucheler, J.

    1995-01-01

    A method for measuring canine heart size in radiographs was developed on the basis that there is a good correlation between heart size and body length regardless of the conformation of the thorax. The lengths of the long and short axes of the heart of 100 clinically normal dogs were determined with calipers, and the dimensions were scaled against the length of vertebrae dorsal to the heart beginning with T4. The sum of the long and short axes of the heart expressed as vertebral heart size was 9.7 +/- 0.5 vertebrae. The differences between dogs with a wide or deep thorax, males and females, and right or left lateral recumbency were not significant. The caudal vena cava was 0.75 vertebrae +/- 0.13 in comparison to the length of the vertebra over the tracheal bifurcation

  6. Measurement of Lumbosacral Angle in Normal Radiographs: A ...

    African Journals Online (AJOL)

    normal lumbar lordosis measurement, the retrospective approach is a credible alternative to the prospective ... complaints, low back pain without any radiographically demonstrable ..... effects of hamstring stretching on sagittal spinal curvatures.

  7. Chest radiographic findings and complications of the temporary implantation of the Jarvik-7 artificial heart while patients await orthotopic heart transplantation

    International Nuclear Information System (INIS)

    Sadler, L.; Fuhrman, C.; Hardesty, R.; Griffith, B.

    1987-01-01

    At the University of Pittsburgh, the authors have had 15 patients in whom Jarvik-7 hearts were implanted as a temporary measure while the patients awaited suitable donors for cardiac transplantation. The paper presents a brief description of the Jarvik-7 artificial heart, factors affecting patient selection, and the radiographic appearance of a normally functioning Jarvik-7 heart, and reviews the chest radiographic complications seen in this patient group, along with eventual patient outcome

  8. Collagenase chemonucleolysis: a long term radiographic study in normal dogs

    International Nuclear Information System (INIS)

    Atilola, M.A.O.; Cockshutt, J.R.; Mclaughlin, R.; Cochrane, S.M.; Pennock, P.W.

    1993-01-01

    Five clinically normal five year old dogs were used in this study. From a randomized table intervertebral discs were each injected with either collagenase or calcium chloride diluent. The surgically exposed cervical discs were injected with 50 units whereas thoracic and lumbar discs were injected under fluoroscopic guidance with 100 units of the enzyme. Postinjection radiographs revealed significant (p ltoreq .05) disc space narrowing in enzyme injected discs. The cervical discs had the highest frequency of radiographic narrowing (87%) followed by the thoracic (70%) and lumbar (53%) discs. Spondylosis deformans developed at the sites of cervical enzyme injections. None of the dogs had neurologic abnormalities one year postinjection

  9. Visions of normality? Early experiences of radiographic reporting

    Energy Technology Data Exchange (ETDEWEB)

    Reeves, Pauline E-mail: pauline.reeves@whnt.nhs.uk

    2004-08-01

    This article reflects on my early [student] experiences in learning to undertake radiographic reporting and uses critical incidents to highlight two areas of error during this period. These errors include perceptual (optical illusions and, in particular, the Mach band effect) and lack of subject specific knowledge (specifically anatomical knowledge--especially of normal anatomical variants). These two errors are analysed in the wider context of radiological error and the difficulty in reaching consensus even between experienced reporters.

  10. Visions of normality? Early experiences of radiographic reporting

    International Nuclear Information System (INIS)

    Reeves, Pauline

    2004-01-01

    This article reflects on my early [student] experiences in learning to undertake radiographic reporting and uses critical incidents to highlight two areas of error during this period. These errors include perceptual (optical illusions and, in particular, the Mach band effect) and lack of subject specific knowledge (specifically anatomical knowledge--especially of normal anatomical variants). These two errors are analysed in the wider context of radiological error and the difficulty in reaching consensus even between experienced reporters

  11. Vertebral scale system to measure heart size in thoracic radiographs ...

    African Journals Online (AJOL)

    In veterinary diagnostic radiology, determination of heart size is necessary in the assessment of patients with clinical signs of cardiac anomaly. In this study, heart sizes were compared with lengths of mid-thoracic vertebrae in 12 clinically normal West African Dwarf Goats (WADGs) (8 females, 4 males). The aim of the ...

  12. Assessment of congestive heart failure in chest radiographs

    International Nuclear Information System (INIS)

    Henriksson, L.; Sundin, A.; Smedby, Oe.; Albrektsson, P.

    1990-01-01

    The effect of observer variations and film-screen quality on the diagnosis of congestive heart failure based on chest radiographs was studied in 27 patients. For each patient, two films were exposed, one with the Kodak Lanex Medium system and one with the Agfa MR 400 system. The films were presented to three observers who assessed the presence of congestive heart failure on a three-graded scale. The results showed no significant difference between the two systems but large systematic differences between the observers. There were also differences between the two ratings by the same observer that could not be explained by the film-screen factor. It is concluded that the choice between these two systems is of little importance in view of the interobserver and intraobserver variability that can exist within the same department. (orig.)

  13. Radiographic normal range of condylar movement of mandible

    International Nuclear Information System (INIS)

    Choi, Byung Ihn; Lee, Jae Mun; Kim, Myung Jin

    1981-01-01

    It is the purpose of this article to determine various normal anatomic measurements of temporomandibular joint and normal range of condylar movement using relatively simple X-ray equipment and radiographic technique in consideration of popular clinical application. Author's cases consisted of 100 clinically normal adult males and temporomandibular joint radiographs of 3 serial positions of condylar head were taken by transcranial oblique lateral projection in each case. The serial positions are centric occlusion, 1 inch opening and maximal opening position. The results were as follows; 1. In centric occlusion, the length between the condylar head and glenoid fossa was 2.23 ± 0.58 mm in anterior part, 3.55 ± 0.80 mm in upper part and 2.76 ± 0.72 mm in posterior part. 2. In centric occlusion, the angle (α) between the horizontal standard line (AB) and anterior slope (BC) was 37.22 ± 3.87 .deg. . 3. In 1 inch opening position, the distance between the summit of condylar head from the standard point of articular eminence (B) was -0.64 ± 3.53 mm in horizontal direction and -1.07 ± 1.00 mm in vertical direction. 4. In maximal opening position, the distance between the summit of condylar head from the standard point of articular eminence (B) was 5.83 ± 3.05 mm in horizontal direction and +0.29 ± 1.58 mm in vertical direction. 5. In positional relationship between the condylar head and the standard point of articular eminence (B), the condyles were found to be at the eminences or anterior to them in 51% with 1 inch opening and 95% with maximal opening

  14. "Porcelain heart" cardiomyopathy secondary to hyperparathyroidism: radiographic, echocardiographic, and cardiac CT appearances.

    LENUS (Irish Health Repository)

    Freeman, James

    2012-02-01

    We report the radiographic, echocardiographic and cardiac CT appearances of \\'porcelain heart\\' in an 85-year-old woman who presented with progressive heart failure. The extensive myocardial calcification was secondary to hyperparathyroidism with renal failure.

  15. "Porcelain heart" cardiomyopathy secondary to hyperparathyroidism: radiographic, echocardiographic, and cardiac CT appearances.

    LENUS (Irish Health Repository)

    Freeman, James

    2010-11-01

    We report the radiographic, echocardiographic and cardiac CT appearances of \\'porcelain heart\\' in an 85-year-old woman who presented with progressive heart failure. The extensive myocardial calcification was secondary to hyperparathyroidism with renal failure.

  16. Chest radiographic findings and complications of the temporary implantation of the Jarvik-7 artificial heart while awaiting orthotopic heart transplantation: Experience with five cases

    International Nuclear Information System (INIS)

    Sadler, L.R.; Fuhrman, C.R.; Hardesty, R.A.; Griffith, B.P.

    1986-01-01

    The Jarvik-7 artificial heart was originally introduced as a therapeutic alternative to cardiac transplantation in patients with endstage refractory cardiac disease. Its use has been expanded to those patients awaiting cardiac transplantation in whom death is impending and for whom a suitable donor match is unavailable. At Presbyterian-University Hospital of Pittsburgh five patients have had Jarvik-7 hearts implanted as a temporary measure while awaiting compatible donors for cardiac transplantation. The authors believe this is the largest patient group to undergo this procedure at a single institution. They present a brief description of the Jarvik-7 heart, the clinical factors affecting patient selection, and the radiographic appearance of a normally functioning Jarvik-7 heart, and review the chest radiographic complications seen in the patient group, along with eventual patient outcome

  17. Exercises in anatomy: the normal heart.

    Science.gov (United States)

    Anderson, Robert H; Sarwark, Anne; Spicer, Diane E; Backer, Carl L

    2014-01-01

    In the first of our exercises in anatomy, created for the Multimedia Manual of the European Association of Cardiothoracic Surgery, we emphasized that thorough knowledge of intracardiac anatomy was an essential part of the training for all budding cardiac surgeons, explaining how we had used the archive of congenitally malformed hearts maintained at Lurie Children's Hospital in Chicago to prepare a series of videoclips, demonstrating the salient features of tetralogy of Fallot. In this series of videoclips, we extend our analysis of the normal heart, since for our initial exercise we had concentrated exclusively on the structure of the right ventricular outflow tract. We begin our overview of normal anatomy by emphasizing the need, in the current era, to describe the heart in attitudinally appropriate fashion. Increasingly, clinicians are demonstrating the features of the heart as it is located within the body. It is no longer satisfactory, therefore, to describe these components in a 'Valentine' fashion, as continues to be the case in most textbooks of normal or cardiac anatomy. We then emphasize the importance of the so-called morphological method, which states that structures within the heart should be defined on the basis of their own intrinsic morphology, and not according to other parts, which are themselves variable. We continue by using this concept to show how it is the appendages that serve to distinguish between the atrial chambers, while the apical trabecular components provide the features to distinguish the ventricles. We then return to the cardiac chambers, emphasizing features of surgical significance, in particular the locations of the cardiac conduction tissues. We proceed by examining the cardiac valves, and conclude by providing a detailed analysis of the septal structures. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. Limited value of interlaced ECG-gated radiography in the presence of a normal chest radiograph

    International Nuclear Information System (INIS)

    Chen, J.T.T.; Ravin, C.E.; Handel, D.

    1984-01-01

    Twenty-seven patients with normal posteroanterior and lateral chest radiographs, who were undergoing cardiac catheterization because of symptoms strongly suggesting coronary artery disease, also had posteroanterior and lateral interlaced electrocardiogram-gated radiographs made. In 14 patients, the interlaced radiography system underestimated (suggested hypokinesia) the wall motion, which was normal on cardiac catheterization. In two cases the system overestimated the wall motion, in two others it both under- and overestimated the motion, and in only nine cases was the correlation correct. These data suggest that the technique is of limited application, particularly in cases in which the routine chest radiographs are normal

  19. Radiographic protocol and normal anatomy of the hind feet in the white rhinoceros (Ceratotherium simum).

    Science.gov (United States)

    Dudley, Robert J; Wood, Simon P; Hutchinson, John R; Weller, Renate

    2015-01-01

    Foot pathology is a common and important health concern in captive rhinoceroses worldwide, but osteopathologies are rarely diagnosed, partly because of a lack of radiographic protocols. Here, we aimed to develop the first radiographic protocol for rhinoceros feet and describe the radiographic anatomy of the white rhinoceros (Ceratotherium simum) hind foot (pes). Computed tomographic images were obtained of nine cadaver pedes from seven different white rhinoceroses and assessed for pathology. A single foot deemed free of pathology was radiographed using a range of different projections and exposures to determine the best protocol. 3D models were produced from the CT images and were displayed with the real radiographs to describe the normal radiographic anatomy of the white rhinoceros pes. An optimal radiographic projection was determined for each bone in the rhinoceros pes focusing on highlighting areas where pathology has been previously described. The projections deemed to be most useful were D60Pr-PlDiO (digit III), D45Pr45M-PlDiLO (digit II), and D40Pr35L-PlDiLO (digit IV). The primary beam was centered 5-7 cm proximal to the cuticle on the digit of interest. Articular surfaces, ridges, grooves, tubercles, processes and fossae were identified. The radiographic protocol we have developed along with the normal radiographic anatomy we have described will allow for more accessible and effective diagnosis of white rhinoceros foot osteopathologies. © 2014 American College of Veterinary Radiology.

  20. Shoulder arthroplasty. Part 2: Normal and abnormal radiographic findings

    International Nuclear Information System (INIS)

    Sheridan, B.D.; Ahearn, N.; Tasker, A.; Wakeley, C.; Sarangi, P.

    2012-01-01

    Frequently, the decision made by general practitioners or musculoskeletal triage assessment services to refer patients for specialist review is initiated by a radiological report. Following shoulder arthroplasty it is important to ensure that any patient with asymptomatic evidence of a failing prosthesis is referred for review so that revision surgery can be contemplated and planned before the situation becomes unsalvageable. The first paper in this series described the various types of shoulder arthroplasty and indications for each. This follow-up paper will concentrate on their modes of failure and the associated radiographic features, and is aimed at radiology trainees and non-musculoskeletal specialist radiologists.

  1. Shoulder arthroplasty. Part 2: Normal and abnormal radiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Sheridan, B.D., E-mail: bdsheridan@hotmail.com [Department of Orthopaedic Surgery, Bristol Royal Infirmary, Bristol (United Kingdom); Ahearn, N.; Tasker, A.; Wakeley, C.; Sarangi, P. [Department of Orthopaedic Surgery, Bristol Royal Infirmary, Bristol (United Kingdom)

    2012-07-15

    Frequently, the decision made by general practitioners or musculoskeletal triage assessment services to refer patients for specialist review is initiated by a radiological report. Following shoulder arthroplasty it is important to ensure that any patient with asymptomatic evidence of a failing prosthesis is referred for review so that revision surgery can be contemplated and planned before the situation becomes unsalvageable. The first paper in this series described the various types of shoulder arthroplasty and indications for each. This follow-up paper will concentrate on their modes of failure and the associated radiographic features, and is aimed at radiology trainees and non-musculoskeletal specialist radiologists.

  2. Radiographic appearance of the normal temporomandibular joint in newborns and small children

    International Nuclear Information System (INIS)

    Larheim, T.A.

    1981-01-01

    The radiographic anatomy of the normal temporomandibular joint in newborns and children up to 4 years of age was investigated, partly on specimens, obtained at autopsy, with methods corresponding to clinical procedures, and partly on patients. A rather flat mandibular fossa and immature mandibular head were found at birth, whereas a well-developed articular tubercle and an adult-like radiographic appearance of the joint were found at about one year of age. No evident changes of the radiographic anatomy seemed to occur from one to 4 years of age. A striking similarity was observed between the dystrophic temporomandibular joint in patients with juvenile rheumatoid arthritis and micrognathia and the normal radiographic appearance in the first months of life, indicating an early involvement of this joint in patients developing micrognathia. (Auth.)

  3. Dentigerous Cystic Changes in the Follicles Associated with Radiographically Normal Impacted Mandibular Third Molars

    OpenAIRE

    Ashok Dongol; Alok Sagtani; Mehul Rajesh Jaisani; Arpita Singh; Ashish Shrestha; Anju Pradhan; Pradeep Acharya; Anjani Kumar Yadav; Ram Prasad Yadav; Arun Kumar Mahat; Iccha Kumar Maharjan; Leeza Pradhan

    2018-01-01

    Objective. To assess the incidence of dentigerous cystic changes in the follicles of radiographically normal impacted mandibular third molars. Methods. One hundred and thirteen follicles obtained after surgical removal of impacted mandibular third molars with radiolucency of less than 2.5 mm in the radiograph were sent for histopathologic evaluation to evaluate pathologic changes. Results. The incidence of dentigerous cystic changes observed was 15.9%, that is, 18 out of 113 patients (51 male...

  4. Measurement of Lumbosacral Angle in Normal Radiographs: A ...

    African Journals Online (AJOL)

    hyper.lordosis; most of the data in use in medical practice are based on studies on other races. Aim: To quantify the normal LSA in our population. Subjects and Methods: LSA was measured by the Fergusonfs technique and the data analyzed with SPSS Statistics version 17.0 (Chicago IL, USA). Results: LSA varied between ...

  5. The radiographic anatomy of the normal ovine digit, the metacarpophalangeal and metatarsophalangeal joints.

    Science.gov (United States)

    Duncan, Jennifer S; Singer, Ellen R; Devaney, Jane; Oultram, Joanne W H; Walby, Anna J; Lester, Bridie R; Williams, Helen J

    2013-03-01

    The aim of this project was to develop a detailed, accessible set of reference images of the normal radiographic anatomy of the ovine digit up to and including the metacarpo/metatatarsophalangeal joints. The lower front and hind limbs of 5 Lleyn ewes were radiographed using portable radiography equipment, a digital image processer and standard projections. Twenty images, illustrating the normal radiographic anatomy of the limb were selected, labelled and presented along with a detailed description and corresponding images of the bony skeleton. These images are aimed to be of assistance to veterinary surgeons, veterinary students and veterinary researchers by enabling understanding of the normal anatomy of the ovine lower limb, and allowing comparison with the abnormal.

  6. Normal xeroradiographic and radiographic anatomy of the mallard duck (Anas platyrhynchos) with reference to other anserine species

    Energy Technology Data Exchange (ETDEWEB)

    Smith, B. J. [North Carolina State University, Raleigh (United States); Smith, S. A.

    1991-03-15

    he purpose of this study was to provide a reference for xeroradiographic and conventional radiographic anatomy of the mallard duck (Anas platyrhynchos) as a representative of the avian Order Anseriformes. The head, body, wing, and pelvic limb of three adult birds were radiographed using xeroradiographic and conventional radiographic techniques. Nine xeroradiographs and their corresponding conventional radiographs were selected, and the xeroradiographs labeled to illustrate normal anatomy. Selected views of other anseriform species were included to illustrate certain anatomical features unique to those species.

  7. Normal xeroradiographic and radiographic anatomy of the mallard duck (Anas platyrhynchos) with reference to other anserine species

    International Nuclear Information System (INIS)

    Smith, B.J.; Smith, S.A.

    1991-01-01

    he purpose of this study was to provide a reference for xeroradiographic and conventional radiographic anatomy of the mallard duck (Anas platyrhynchos) as a representative of the avian Order Anseriformes. The head, body, wing, and pelvic limb of three adult birds were radiographed using xeroradiographic and conventional radiographic techniques. Nine xeroradiographs and their corresponding conventional radiographs were selected, and the xeroradiographs labeled to illustrate normal anatomy. Selected views of other anseriform species were included to illustrate certain anatomical features unique to those species

  8. Diagnostic significance of gallium lung uptake in patients with normal chest radiographs

    International Nuclear Information System (INIS)

    MacMahon, H.; Bekerman, C.

    1978-01-01

    Nine patients were encountered with normal chest radiographs, but diffuse bilateral lung uptake of 67 Ga-citrate. They were divided into three groups. The first consisted of 6 patients who had lymphoma or leukemia and had had multiple cycles of chemotherapy. Here, abnormal uptake may have resulted from a toxic effect of the drugs or from a low-grade, subclinical infectious process. The 2 patients in the second group were drug addicts and a subradiographic interstitial inflammatory reaction was probably responsible for abnormal uptake. The last patient had diffuse uptake of 67 Ga-citrate throughout the lungs two weeks before lymphomatous infiltrates became radiographically visible

  9. Accuracy of chest radiographs in the emergency diagnosis of heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Studler, Ueli; Kretzschmar, Martin; Steinbrich, Wolfgang [University Hospital Basel, Department of Radiology, Basel (Switzerland); Christ, Michael; Breidthardt, Tobias; Noveanu, Markus; Perruchoud, Andre P.; Mueller, Christian [University Hospital Basel, Department of Internal Medicine, Basel (Switzerland); Schoetzau, Andreas [Institute of Biostatistics, Basel (Switzerland)

    2008-08-15

    The purpose of this study was to determine the diagnostic accuracy of chest radiographic findings of heart failure (HF) in current patients presenting with dyspnea in the emergency department. In a secondary analysis of the BASEL study, initial chest radiographs of 277 patients with acute dyspnea were evaluated by two radiologists blinded to the adjudicated diagnosis (56% had the final diagnosis of HF). Predefined radiographic criteria of HF were used. Statistical analysis included receiver-operating characteristic (ROC) analysis and calculation of a logistic regression model including B-type natriuretic peptide (BNP) levels. The reader's overall impression showed the highest area under the ROC curve for the diagnosis of HF in both supine and erect patient positions (0.855 and 0.857). Among individual radiographic findings, peribronchial cuffing in the supine position (0.829) showed the highest accuracies. The lowest accuracy was found for the vascular pedicle width in the supine position (0.461). Logistic regression analysis showed no significant differences between the reader's overall impression, the radiographic model, and BNP testing. In our study, the combination of radiographic features provided valuable information and was of comparable accuracy as BNP-testing for the diagnosis of HF. (orig.)

  10. The accuracy of chest radiographs in the detection of congenital heart disease and in the diagnosis of specific congenital cardiac lesions

    International Nuclear Information System (INIS)

    Laya, Bernard F.; Goske, Marilyn J.; Morrison, Stuart; Reid, Janet R.; Swischuck, Leonard; Ey, Elizabeth H.; Murphy, Daniel J.; Lieber, Michael; Obuchowski, Nancy

    2006-01-01

    Congenital heart disease (CHD) is a significant cause of morbidity and mortality in pediatric patients. Traditional teaching holds that specific types of CHD can be diagnosed on the chest radiograph (CXR) through pattern recognition. To determine the accuracy of radiologists in detecting CHD on the CXR. This study was a blinded retrospective review of chest radiographs from 281 patients (<12 years) by five pediatric radiologists from three institutions. Thirteen groups were evaluated that included 12 categories of CHD and a control group of patients without heart disease. Radiographs were assessed for heart size, heart and mediastinal shape and vascularity. Clinical information, angiography, echocardiograms and surgery were used as the gold standard for definitive diagnosis. The average accuracy of the five readers in distinguishing normal from CHD patients was 78% (range of 72% to 82%). The overall measure of accuracy in distinguishing specific congenital cardiac lesions among 13 groups of patients was 71% (range of 63% to 79%). CXR alone is not diagnostic of specific cardiac lesions, with a low accuracy of only 71%. We believe that less emphasis should be placed on the use of radiographs alone in diagnosing specific congenital cardiac lesions. (orig.)

  11. Normal position and malposition of the heart

    International Nuclear Information System (INIS)

    Andresen, J.H.; Eggert Hansen, T.

    1980-01-01

    The main types of heart positions and the malpositions are described as demonstrated on plain films of the thorax. Special attention is drawn to the situs ambiguous with the poly- or asplenia which may be recognized from hypoarterial or epiarterial position of the main bronchi and their equal lengths and courses. This diagnosis is important because of the frequent accompanying congenital cardiac malformations and in respect to the planning of angiocardiography. (orig.) [de

  12. Comparison of radiographic and anatomic femoral varus angle measurements in normal dogs.

    Science.gov (United States)

    Swiderski, Jennifer K; Radecki, Steven V; Park, Richard D; Palmer, Ross H

    2008-01-01

    To determine if the clinically practiced method of radiographic femoral varus angle (R-FVA) measurement is repeatable, reproducible, and accurate. Radiographic and anatomic study. ANIMALS/SAMPLE POPULATION: Normal Walker hound cadavers (n=5) and femora (n=10). Cadavers were held in dorsally-recumbent and torso-elevated positions as 3 craniocaudal radiographs were made of each femur, by each of 2 different technicians. Femora were then harvested for direct measurement of anatomic femoral varus angle (A-FVA). R-FVA was measured on each radiograph by each of 3 examiners on 3 separate occasions. Intra-observer (repeatability) and inter-observer (reproducibility) variance in R-FVA measurement and the strength of relationship between R-FVA and A-FVA (accuracy) were determined. Mean (+/-SD) A-FVA was 5.2+/-2.1 degrees (range, 2.4-8.2 degrees). Mean (+/-SD) R-FVA was 5.8+/-1.0 degrees (range, 2.7-9.6 degrees). Intra-observer variance (range: 11-16%) and inter-observer variance (16%) were acceptable. The strength of relationship between measured R-FVA and A-FVA (maximum adjusted R(2)hounds. The detected inaccuracy may be real or the result of a selection bias for normal dogs obscuring the true relationship. R-FVA may not be an accurate method of femoral varus measurement in dogs with A-FVA10 degrees), the procedure would not have been erroneously performed in any of the normal dogs of this study.

  13. Radiographic Evaluation of Valvular Heart Disease With Computed Tomography and Magnetic Resonance Correlation.

    Science.gov (United States)

    Lempel, Jason K; Bolen, Michael A; Renapurkar, Rahul D; Azok, Joseph T; White, Charles S

    2016-09-01

    Valvular heart disease is a group of complex entities with varying etiologies and clinical presentations. There are a number of imaging tools available to supplement clinical evaluation of suspected valvular heart disease, with echocardiography being the most common and clinically established, and more recent emergence of computed tomography and magnetic resonance imaging as additional supportive techniques. Yet even with these newer and more sophisticated modalities, chest radiography remains one of the earliest and most common diagnostic examinations performed during the triage of patients with suspected cardiac dysfunction. Recognizing the anatomic and pathologic features of cardiac radiography including the heart's adaptation to varying hemodynamic changes can provide clues to the radiologist regarding the underlying etiology. In this article, we will elucidate several principles relating to chamber modifications in response to pressure and volume overload as well as radiographic appearances associated with pulmonary fluid status and cardiac dysfunction. We will also present a pattern approach to optimize analysis of the chest radiograph for valvular heart disease, which will help guide the radiologist down a differential diagnostic pathway and create a more meaningful clinical report.

  14. Pediatric cervical spine in emergency: radiographic features of normal anatomy, variants and pitfalls

    International Nuclear Information System (INIS)

    Adib, Omar; Berthier, Emeline; Loisel, Didier; Aube, Christophe

    2016-01-01

    Injuries of the cervical spine are uncommon in children. The distribution of injuries, when they do occur, differs according to age. Young children aged less than 8 years usually have upper cervical injuries because of the anatomic and biomechanical properties of their immature spine, whereas older children, whose biomechanics more closely resemble those of adults, are prone to lower cervical injuries. In all cases, the pediatric cervical spine has distinct radiographic features, making the emergency radiological analysis of it difficult. Such features as hypermobility between C2 and C3, pseudospread of the atlas on the axis, pseudosubluxation, the absence of lordosis, anterior wedging of vertebral bodies, pseudowidening of prevertebral soft tissue and incomplete ossification of synchondrosis can be mistaken for traumatic injuries. The interpretation of a plain radiograph of the pediatric cervical spine following trauma must take into account the age of the child, the location of the injury and the mechanism of trauma. Comprehensive knowledge of the specific anatomy and biomechanics of the childhood spine is essential for the diagnosis of suspected cervical spine injury. With it, the physician can, on one hand, differentiate normal physes or synchondroses from pathological fractures or ligamentous disruptions and, on the other, identify any possible congenital anomalies that may also be mistaken for injury. Thus, in the present work, we discuss normal radiological features of the pediatric cervical spine, variants that may be encountered and pitfalls that must be avoided when interpreting plain radiographs taken in an emergency setting following trauma. (orig.)

  15. Pediatric cervical spine in emergency: radiographic features of normal anatomy, variants and pitfalls.

    Science.gov (United States)

    Adib, Omar; Berthier, Emeline; Loisel, Didier; Aubé, Christophe

    2016-12-01

    Injuries of the cervical spine are uncommon in children. The distribution of injuries, when they do occur, differs according to age. Young children aged less than 8 years usually have upper cervical injuries because of the anatomic and biomechanical properties of their immature spine, whereas older children, whose biomechanics more closely resemble those of adults, are prone to lower cervical injuries. In all cases, the pediatric cervical spine has distinct radiographic features, making the emergency radiological analysis of it difficult. Such features as hypermobility between C2 and C3, pseudospread of the atlas on the axis, pseudosubluxation, the absence of lordosis, anterior wedging of vertebral bodies, pseudowidening of prevertebral soft tissue and incomplete ossification of synchondrosis can be mistaken for traumatic injuries. The interpretation of a plain radiograph of the pediatric cervical spine following trauma must take into account the age of the child, the location of the injury and the mechanism of trauma. Comprehensive knowledge of the specific anatomy and biomechanics of the childhood spine is essential for the diagnosis of suspected cervical spine injury. With it, the physician can, on one hand, differentiate normal physes or synchondroses from pathological fractures or ligamentous disruptions and, on the other, identify any possible congenital anomalies that may also be mistaken for injury. Thus, in the present work, we discuss normal radiological features of the pediatric cervical spine, variants that may be encountered and pitfalls that must be avoided when interpreting plain radiographs taken in an emergency setting following trauma.

  16. Pediatric cervical spine in emergency: radiographic features of normal anatomy, variants and pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Adib, Omar; Berthier, Emeline; Loisel, Didier; Aube, Christophe [University Hospital of Angers, Department of Radiology, Angers (France)

    2016-12-15

    Injuries of the cervical spine are uncommon in children. The distribution of injuries, when they do occur, differs according to age. Young children aged less than 8 years usually have upper cervical injuries because of the anatomic and biomechanical properties of their immature spine, whereas older children, whose biomechanics more closely resemble those of adults, are prone to lower cervical injuries. In all cases, the pediatric cervical spine has distinct radiographic features, making the emergency radiological analysis of it difficult. Such features as hypermobility between C2 and C3, pseudospread of the atlas on the axis, pseudosubluxation, the absence of lordosis, anterior wedging of vertebral bodies, pseudowidening of prevertebral soft tissue and incomplete ossification of synchondrosis can be mistaken for traumatic injuries. The interpretation of a plain radiograph of the pediatric cervical spine following trauma must take into account the age of the child, the location of the injury and the mechanism of trauma. Comprehensive knowledge of the specific anatomy and biomechanics of the childhood spine is essential for the diagnosis of suspected cervical spine injury. With it, the physician can, on one hand, differentiate normal physes or synchondroses from pathological fractures or ligamentous disruptions and, on the other, identify any possible congenital anomalies that may also be mistaken for injury. Thus, in the present work, we discuss normal radiological features of the pediatric cervical spine, variants that may be encountered and pitfalls that must be avoided when interpreting plain radiographs taken in an emergency setting following trauma. (orig.)

  17. Normal xeroradiographic and radiographic anatomy of the bobwhite quail (Colinus virginianus), with reference to other galliform species

    International Nuclear Information System (INIS)

    Smith, B.J.; Smith, S.A.

    1991-01-01

    The purpose of this study was to provide a reference for xeroradiographic and conventional radiographic anatomy of the bobwhite quail (Colinus virginianus) as a representative of the avian order Galliformes. The heads, bodies, wings, and pelvic limbs of four adult birds were radiographed using xeroradiographic and conventional radiographic techniques. Nine xeroradiographs and their corresponding conventional radiographs were selected, and the xeroradiographs labeled to illustrate the normal anatomy of these regions. A xeroradiograph of the tarsometatarsus of the domestic peacock (Pavo cristatus) was also included to demonstrate the metatarsal spur, which is not present in the quail

  18. Cardiothoracic ratio on chest radiograph in pediatric heart disease: How does it correlate with heart volumes at magnetic resonance imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Grotenhuis, Heynric B. [The University of Toronto, Division of Cardiology, Department of Paediatrics, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto (Canada); Zhou, Cheng; Isaac, Kathryn V. [The University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada); Tomlinson, George [University of Toronto, Department of Medicine, Toronto General Hospital and Mt. Sinai Hospital, Toronto (Canada); Seed, Mike; Grosse-Wortmann, Lars; Yoo, Shi-Joon [The University of Toronto, Division of Cardiology, Department of Paediatrics, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto (Canada); The University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada)

    2015-10-15

    The cardiothoracic ratio by chest radiograph is widely used as a marker of cardiac size. The purpose of this study is to correlate cardiothoracic ratio and cardiac volumes as measured by cardiovascular magnetic resonance (MR) in common structural and myopathic heart disease with increased cardiac size due to volume overload or hypertrophy. A retrospective single center study was performed in all patients between 2007 and 2013 with repaired tetralogy of Fallot (TOF), aortic regurgitation, isolated left-to-right shunt and hypertrophic cardiomyopathy (HCM) who underwent cardiovascular MR and chest radiograph within 6 months of each other. Cardiothoracic ratios by chest radiograph (frontal and lateral) were compared to cardiac volumes (indexed for body surface area) by cardiovascular MR. One hundred twenty-seven patients (mean age: 11.2 ± 5.5 years) were included in this study (76 with TOF, 23 with isolated left-to-right shunt, 16 with aortic regurgitation and 12 with HCM). Frontal cardiothoracic ratio of all groups correlated with indexed right ventricular (RV) end-diastolic volume (EDVI) (r = 0.40, P < 0.01) and indexed total heart volume (THVI) (r = 0.27, P < 0.01). In TOF patients, frontal cardiothoracic ratio correlated with RVEDVI (r = 0.34, P < 0.01; coefficient of variation = 27.6%), indexed RV end-systolic volume (ESVI) (r = 0.44, P < 0.01; coefficient of variation = 33.3%) and THVI (r = 0.35, P < 0.01; coefficient of variation = 19.6%), although RV volumes and THVI showed widespread variation given the high coefficients of variation. In patients with aortic regurgitation, frontal cardiothoracic ratio correlated with left ventricular (LV) EDVI (r = 0.50, P = 0.047), but not with THVI and aortic regurgitant fraction, and widespread variation for LV EDVI (coefficient of variation = 19.2%), LV ESVI (coefficient of variation = 32.5%) and THVI (coefficient of variation = 13.6%) was also observed. Frontal cardiothoracic ratio was not correlated with cardiac volumes

  19. Influence of cardiac cycle on the radiographic appearance of the feline heart

    International Nuclear Information System (INIS)

    Toal, R.L.; Losonsky, J.M.; Coulter, D.B.; DeNovellis, R.

    1985-01-01

    The effect of cardiac-cycle phase on the radiographic appearance of the feline heart was investigated. Results show that the size and shape changes in the cardiac silhouette due to the cardiac cycle were present in all three postural positions investigated. Cardiac size and shape changes were present more frequently and in more locations of the cardiac silhouette when patients were in ventral recumbency (DV) versus dorsal recumbency (VD). In most cases, the magnitude of differences was small and detection was facilitated by comparison viewing. It is suggested that these size and shape influences of the cardiac cycle on cardiac appearance should be kept in mind when interpreting feline radiographs for cardiac pathology

  20. Dentigerous Cystic Changes in the Follicles Associated with Radiographically Normal Impacted Mandibular Third Molars

    Directory of Open Access Journals (Sweden)

    Ashok Dongol

    2018-01-01

    Full Text Available Objective. To assess the incidence of dentigerous cystic changes in the follicles of radiographically normal impacted mandibular third molars. Methods. One hundred and thirteen follicles obtained after surgical removal of impacted mandibular third molars with radiolucency of less than 2.5 mm in the radiograph were sent for histopathologic evaluation to evaluate pathologic changes. Results. The incidence of dentigerous cystic changes observed was 15.9%, that is, 18 out of 113 patients (51 males and 62 females, with the maximum incidence of cystic changes seen in the follicular space size of 0.5 mm. The mean age of the patients included was 27.8 ± 8.1. The most common indication for extraction among the patients in this study was recurrent pericoronitis (95%. There were no statistically significant differences in occurrence of cystic changes based on age, gender, angulation, relation to ramus, depth, side of impaction, and follicle size (P>0.05. Conclusion. Dental follicles obtained from surgically removed impacted mandibular third molars should be submitted for histopathologic examination irrespective of the radiographic size of the follicle.

  1. Normal left ventricular emptying in coronary artery disease at rest: analysis by radiographic and equilibrium radionuclide ventriculography

    International Nuclear Information System (INIS)

    Denenberg, B.S.; Makler, P.T.; Bove, A.A.; Spann, J.F.

    1981-01-01

    The volume ejected early in systole has been proposed as an indicator of abnormal left ventricular function that is present at rest in patients with coronary artery disease with a normal ejection fraction and normal wall motion. The volume ejected in systole was examined by calculating the percent change in ventricular volume using both computer-assisted analysis of biplane radiographic ventriculograms at 60 frames/s and equilibrium gated radionuclide ventriculograms. Ventricular emptying was examined with radiographic ventriculography in 33 normal patients and 23 patients with coronary artery disease and normal ejection fraction. Eight normal subjects and six patients with coronary artery disease had both radiographic ventriculography and equilibrium gated radionuclide ventriculography. In all patients, there was excellent correlation between the radiographic and radionuclide ventricular emptying curves (r . 0.971). There were no difference in the ventricular emptying curves of normal subjects and patients with coronary artery disease whether volumes were measured by radiographic or equilibrium gated radionuclide ventriculography. It is concluded that the resting ventricular emptying curves are identical in normal subjects and patients with coronary artery disease who have a normal ejection fraction and normal wall motion

  2. Right heart enlargement in heartworm-infected dogs: a radiographic, electrocardiographic, and echocardiographic correlation

    International Nuclear Information System (INIS)

    Lombard, C.W.; Ackerman, N.

    1984-01-01

    Radiographically, the size of the right ventricle of 54 heartworm-infected dogs was graded subjectively as normal, 1 +, 2 +, and 3 + and served to classify the dogs into groups A, B, C, and D. With M-mode echocardiograms, right ventricular enlargement ratios (RVE ratios) were determined for each dog by dividing the measured right ventricular internal diastolic dimension (RVIDd) by the expected RVIDd of a normal dog of the same body weight. The normal RVIDd relation to body weight was derived from 25 healthy heartworm-free control dogs. These two variables were linearly related with a correlation coefficient r 2 = 0.59. Means and standard deviations of the RVE ratio were calculated for each group. Despite wide ranges and considerable overlap, the ratio was significantly different (t-test, p < 0.005) between groups with the exception of groups A and B, and C and D. The incidence of electrocardiographic signs of right ventricular hypertrophy was also determined for each group; it was 38% in group C and 62% in group D. From this data, it was concluded that M-mode echocardiography is a very sensitive technique for the documentation of right ventricular dilatation in heartworm-infected dogs, correlating with radiographic impressions of right ventricular enlargement. (author)

  3. Hyaline cartilage thickness in radiographically normal cadaveric hips: comparison of spiral CT arthrographic and macroscopic measurements.

    Science.gov (United States)

    Wyler, Annabelle; Bousson, Valérie; Bergot, Catherine; Polivka, Marc; Leveque, Eric; Vicaut, Eric; Laredo, Jean-Denis

    2007-02-01

    To assess spiral multidetector computed tomographic (CT) arthrography for the depiction of cartilage thickness in hips without cartilage loss, with evaluation of anatomic slices as the reference standard. Permission to perform imaging studies in cadaveric specimens of individuals who had willed their bodies to science was obtained from the institutional review board. Two independent observers measured the femoral and acetabular hyaline cartilage thickness of 12 radiographically normal cadaveric hips (from six women and five men; age range at death, 52-98 years; mean, 76.5 years) on spiral multidetector CT arthrographic reformations and on coronal anatomic slices. Regions of cartilage loss at gross or histologic examination were excluded. CT arthrographic and anatomic measurements in the coronal plane were compared by using Bland-Altman representation and a paired t test. Differences between mean cartilage thicknesses at the points of measurement were tested by means of analysis of variance. Interobserver and intraobserver reproducibilities were determined. At CT arthrography, mean cartilage thickness ranged from 0.32 to 2.53 mm on the femoral head and from 0.95 to 3.13 mm on the acetabulum. Observers underestimated cartilage thickness in the coronal plane by 0.30 mm +/- 0.52 (mean +/- standard error) at CT arthrography (P cartilage thicknesses at the different measurement points was significant for coronal spiral multidetector CT arthrography and anatomic measurement of the femoral head and acetabulum and for sagittal and transverse CT arthrography of the femoral head (P cartilage thickness from the periphery to the center of the joint ("gradients") were found by means of spiral multidetector CT arthrography and anatomic measurement. Spiral multidetector CT arthrography depicts cartilage thickness gradients in radiographically normal cadaveric hips. (c) RSNA, 2007.

  4. General anesthesia suppresses normal heart rate variability in humans

    Science.gov (United States)

    Matchett, Gerald; Wood, Philip

    2014-06-01

    The human heart normally exhibits robust beat-to-beat heart rate variability (HRV). The loss of this variability is associated with pathology, including disease states such as congestive heart failure (CHF). The effect of general anesthesia on intrinsic HRV is unknown. In this prospective, observational study we enrolled 100 human subjects having elective major surgical procedures under general anesthesia. We recorded continuous heart rate data via continuous electrocardiogram before, during, and after anesthesia, and we assessed HRV of the R-R intervals. We assessed HRV using several common metrics including Detrended Fluctuation Analysis (DFA), Multifractal Analysis, and Multiscale Entropy Analysis. Each of these analyses was done in each of the four clinical phases for each study subject over the course of 24 h: Before anesthesia, during anesthesia, early recovery, and late recovery. On average, we observed a loss of variability on the aforementioned metrics that appeared to correspond to the state of general anesthesia. Following the conclusion of anesthesia, most study subjects appeared to regain their normal HRV, although this did not occur immediately. The resumption of normal HRV was especially delayed on DFA. Qualitatively, the reduction in HRV under anesthesia appears similar to the reduction in HRV observed in CHF. These observations will need to be validated in future studies, and the broader clinical implications of these observations, if any, are unknown.

  5. Small intestinal emptying time in normal Beagle dogs: a contrast radiographic study

    International Nuclear Information System (INIS)

    Miyabayashi, T.; Morgan, J.P.; Atilola, M.A.O.; Muhumuza, L.

    1986-01-01

    Gastric emptying time and small intestinal transit time in dogs are frequently discussed. However, it is often of interest to the radiologist to know what normal small intestinal emptying times should be. A total of 15 upper gastrointestinal studies was performed on five internal parasite-free, normal, standard Beagle dogs with three studies on each dog, 6 days apart. The ages and weights of the dogs ranged from 2–8 years and from 12.4–13.7 kg, respectively. Following 24-hour fasting, a dose of 10 ml/kg bw of 60% wt/vol barium sulfate suspension was administered through a stomach tube. Then, sequential radiographs were made at 30-minute intervals until the entire contrast medium column was in the colon and cecum. The mean, standard deviation, and range of gastric emptying time, small intestinal transit time, and small intestinal emptying time were 76 ± 16.7 (30–120), 73 ± 16.4 (30–120), and 214 ± 25.1 (180–300) minutes, respectively. This study offers the possibility that small intestinal emptying time may be used to further evaluate patients with suspected small intestinal partial obstruction, pseudo-obstruction, ischemia, or lymphangiectasia

  6. The intercondylar fossa of the normal canine stifle: an anatomic and radiographic study

    International Nuclear Information System (INIS)

    Fitch, Randall B.; Montgomery, Ronald D.; Milton, James L.; Garrett, Phillip D.; Kincaid, Steven A.; Wright, James C.; Terry, Glenn C.

    1995-01-01

    The intercondylar fossa (ICF) in dogs consists of a cranial outlet, intercondylar shelf, caudal arch, caudal outlet, a medial wall, and a lateral wall. The normal cranial outlet is bell-shape and, in mixed-breed dogs (mean body weight 19.2 kg, N = 21), measured 5.8 mm cranially, 8.1 mm centrally, and 10.3 mm caudally. The ICF is oriented 12 degree from the dorsal plane of the femoral diaphysis and obliqued 7 degree , proximolateral to distomedial, in the sagittal plane. To adjust for dog size, a fossa width index (FWI) was calculated by dividing the cranial outlet width by the distance between epicondyles. The normal FWI as determined in this study was 0.18 cranially, 0.25 centrally, and 0.32 caudally. The fossa height index was 0.31. Contact between the ICF and the cranial cruciate ligament began at about 115 degree of extension. The contact area moved cranially in the intercondylar fossa as the stifle was extended. Evaluation of the ICF can be performed radiographically but positioning is critical

  7. Utility of Chest Computed Tomography after a "Normal" Chest Radiograph in Patients with Thoracic Stab Wounds.

    Science.gov (United States)

    Nguyen, Brian M; Plurad, David; Abrishami, Sadaf; Neville, Angela; Putnam, Brant; Kim, Dennis Y

    2015-10-01

    Chest computed tomography (CCT) is used to screen for injuries in hemodynamically stable patients with penetrating injury. We aim to determine the incidence of missed injuries detected on CCT after a negative chest radiograph (CXR) in patients with thoracic stab wounds. A 10-year retrospective review of a Level I trauma center registry was performed on patients with thoracic stab wounds. Patients who were hemodynamically unstable or did not undergo both CXR and CCT were excluded. Patients with a negative CXR were evaluated to determine if additional findings were diagnosed on CCT. Of 386 patients with stab wounds to the chest, 154 (40%) underwent both CXR and CCT. One hundred and fifteen (75%) had a negative screening CXR. CCT identified injuries in 42 patients (37%) that were not seen on CXR. Pneumothorax and/or hemothorax occurred in 40 patients (35%), of which 14 patients underwent tube thoracostomy. Two patients had hemopericardium on CCT and both required operative intervention. Greater than one-third of patients with a normal screening CXR were found to have abnormalities on CCT. Future studies comparing repeat CXR to CCT are required to further define the optimal diagnostic strategy in patients with stab wounds to chest after normal screening CXR.

  8. Extracorporeal Cardiopulmonary Resuscitation Among Patients with Structurally Normal Hearts.

    Science.gov (United States)

    Conrad, Stephanie J; Bridges, Brian C; Kalra, Yuvraj; Pietsch, John B; Smith, Andrew H

    Extracorporeal cardiopulmonary resuscitation (eCPR) has been well described as a rescue therapy in refractory cardiac arrest among patients with congenital heart disease. The purpose of this retrospective analysis of data from the Extracorporeal Life Support Organization was to evaluate outcomes of eCPR in patients with structurally normal hearts and to identify risk factors that may contribute to mortality. During the study period, 1,431 patients met inclusion criteria. Median age was 16 years. Overall survival to hospital discharge was 32%. Conditional logistic regression demonstrated an independent survival benefit among smaller patients, patients with a lower partial pressure of carbon dioxide (PaCO2) on cannulation, and those with a shorter duration from intubation to eCPR cannulation. A diagnosis of sepsis was independently associated with a nearly threefold increase in odds of mortality, whereas the diagnosis of myocarditis portended a more favorable outcome. Neurologic complications, pulmonary hemorrhage, disseminated intravascular coagulation, CPR, pH less than 7.20, and hyperbilirubinemia after eCPR cannulation were independently associated with an increase in odds of mortality. When utilizing eCPR in patients with structurally normal hearts, a diagnosis of sepsis is independently associated with mortality, whereas a diagnosis of myocarditis is protective. Neurologic complications and pulmonary hemorrhage while on extracorporeal membrane oxygenation (ECMO) are independently associated with mortality.

  9. Comparative study between Steiner's cephalometric-radiographic patterns and the ones of Brazilian's, white teenagers, who present normal occlusion

    International Nuclear Information System (INIS)

    Domingues, A.P. de.

    1986-01-01

    The purpose of this study was to study comparatively the cephalometric-radiographic patterns of Steiner's analysis and the ones of Brazilians, white teenagers, who present normal occlusions. The sample was composed of fifty seven teleradiographies on lateral pattern from Brazilian teenagers. Those teenagers are white and their parents are Brazilian, descended from Mediterraneans. Also the examined teenagers had not undergone previous orthodontic treatment and as it was said above, present normal occlusion. (author) [pt

  10. Radiographic anatomy and technique for arthrography of the cubital joint in clinically normal dogs

    International Nuclear Information System (INIS)

    Lowry, J.E.; Carpenter, L.G.; Park, R.D.; Steyn, P.F.; Schwarz, P.D.

    1993-01-01

    A technique for arthrography of the cubital joint in clinically normal large-breed dogs was developed with the objective of improving visualization of the articular margin of the medial coronoid process. A lateral approach to the cubital joint for injection of contrast medium was selected. Arthrography of 24 cubital joints was performed by using 14 dogs. Twelve combinations of iodinated contrast medium, consisting of various concentrations (3) and volumes (4), were used. Two sets of arthrograms for each of the 12 combinations of contrast medium were obtained. Five radiographic views were used for each set. All arthrograms were examined by 3 evaluators, and each articular surface received a numerical rating for how well it could be seen in each view. Results of the evaluation indicated that low volumes of contrast medium were preferable to high volumes, with 2 ml providing the best visualization. Concentration of iodine seemed less important than did volume. The numerical ratings also indicated that the articular margin of the coronoid process was clearly observed a maximum of only 24% of the time on a slightly supinated mediolateral projection. The articular margins of the head of the radius, trochlea humeri, and trochlear notch were well visualized > 90% of the time. Arthrography of the cubital joint was technically easy to perform, and complications were not encountered, but arthrographic anatomy of the cubital joint is complex. Potential uses for arthrography of the cubital joint include diagnosis of osteochondrosis, intraarticular fragments, and joint capsule ruptures

  11. Quantitative survey radiographic evaluation of the lumbosacral spine of normal dogs and dogs with degenerative lumbosacral stenosis

    International Nuclear Information System (INIS)

    Mattoon, J.S.; Koblik, P.D.

    1993-01-01

    Survey radiographic studies of the lumbosacral region for 93 normal dogs and for 26 dogs with confirmed degenerative lumbosacral stenosis were reviewed. Normal dogs were divided into 9 groups based on age and body weight. For normal dogs, increasing age and body weight were associated with a decreased ability to extend the lumbosacral joint and with increased incidence and severity of spondylosis. Transitional lumbosacral vertebrae and evidence of lumbosacral disc space collapse were very infrequent findings, and the pivot point for lumbosacral motion was consistently centered over the lumbosacral disc space. Relative to an age/weight matched sub-population of normal dogs, dogs with degenerative lumbosacral stenosis had similar mean normalized lumbosacral vertebral canal height, larger mean neutral lumbosacral angle, decreased extension of the lumbosacral joint, increased flexion of the lumbosacral joint, reduced lumbosacral range of motion, increased lumbosacral dynamic malalignment, higher incidence and severity of spondylosis, higher incidence of transitional vertebrae, and higher incidence of lumbosacral disc space collapse. A logistic model based strictly on radiographic parameters was able to discriminate normal from affected dogs with an overall accuracy rate of 86%

  12. Normal cardiac diameters in cine-MRI of the heart

    International Nuclear Information System (INIS)

    Hergan, K.; Schuster, A.; Mair, M.; Burger, R.; Toepker, M.

    2004-01-01

    Purpose: To measure the normal diameters of cardiac cavities in standard cardiac views using cine MRI. Materials and Methods: Fifty-six volunteers were examined (27 male, 29 female) on a 1.5 T MR unit with ECG-triggered single shot free precision (SSFP) cine MR sequences and parallel image acquisition. Standardized echocardiographic planes were used to depict the heart of all volunteers (short axis, 4-chamber view, left and right 2-chamber views). The different diameters of the cardiac cavities were measured using a fixed protocol. Results: For the estimation of ventricular dilatation, the important female/male cross diameters of the left ventricle are 45.2±3.4/51.6±4.6 mm diastolic and 30.5±3.5/33.8±3.6 mm systolic, and of the right ventricle 30.7±3.8/37.1±5.9 mm diastolic and 22.3±3.8/28.1±4.4 mm systolic. For the determination of a left ventricular hypertrophy, relevant septal wall thickness measured in the short axis of the left ventricle of female/male volunteers are 8.0±1.0/9.9±1.2 mm diastolic and 10.9±1.4/13.6±1.9 mm systolic. The measured normal values of male volunteers were generally higher than those of female volunteers. The thickness of the ventricular septum correlated well when measured in the short axis and 4-chamber view. When measured in the 4-chamber view, the longitudinal diameter of the ventricles had a higher value in diastole and a lower value in systole, compared to the 2-chamber views of the right and left cardiac cavities. The atrial longitudinal diameters were higher in the 4-chamber view compared to the 2-chamber views, without any difference in systole or diastole. Conclusion: Diameters of cardiac cavities are easily and quickly measured. Using the tables with the normal values published here, it is simple to estimate an abnormal size of the heart. (orig.)

  13. Cardiothoracic ratio and vertebral heart size (VHS to standardize the heart size of the tufted capuchin (Cebus apella Linnaeus, 1758 in computerized radiographic images

    Directory of Open Access Journals (Sweden)

    Hermínio J. Rocha-Neto

    2015-10-01

    Full Text Available Abstract: The VHS and CTR were assessed using computerized thoracic radiographs of ten clinically healthy tufted capuchin monkeys (five males and five females from the Wild Animal Screening Center in São Luís (Centro de Triagem de Animais Silvestres de São Luís-MA-CETAS. Radiographs were taken in laterolateral and dorsoventral projections to calculate the cardiothoracic ratio (VHS and vertebral heart size (CTR. The VHS showed mean values of 9.34±0.32v (males and 9.16±0.34v (females and there was no statistical difference between males and females (p>0.05. The CTR showed mean values of 0.55±0.04 (males and 0.52±0.03 (females and there was no statistical difference between the sexes (p>0.05. There was positive correlation between VHS and CTR (r=0.78. The thoracic and heart diameters showed mean values of 5.70±0.48cm and 2.16±0.40cm in the males, respectively. In the females they measured 5.32±0.39cm and 2.94±0.32cm. There was no statistical difference between the sexes. Our results show that the high correlation found between VHS and CTR permitted the verification with similar clinical precision between the two methods to estimate alterations in the heart silhouette by radiographic examination of tufted capuchin, making it an easy technique to apply that can be considered in the investigation of heart problems for this wild species.

  14. A study on roentgen anatomy of the normal lateral chest radiograph

    International Nuclear Information System (INIS)

    Konishi, Keiko

    1985-01-01

    CT findings of the various anatomical structures in 70 cases were classified into three types according to their relation to lung, mediastinal tissue (or fat) and the other thoracic organs. Posterior margin of right brachiocephalic vein-superior vena cava complex (RB-SVC), anterior and posterior margins of inferior vena cava, anterior margin of ascending aorta, anterior and posterior margins of aortic arch, posterior wall of bronchus intermedius (PWBI), posterior wall of distal portion of left main bronchus (PWDPLMB) and posterior wall of trachea (posterior tracheal stripe, PTS) were frequently visualized when lung outlined more than half of them. Anterior margin of ascending aorta was also occasionally visualized when a small amount of mediastinal fat outlined it. Anterior margin of right ventricular outflow tract was frequently visualized when lung outlined more than half of it and it was situated anterior to that of ascending aorta. Anterior tracheal stripe was frequently visualized when a large amount of mediastinal fat outlined it. PWBI, PWDPLMB and PTS were frequently visualized when lung outlined them. Cardiac incisura was frequently visualized when a large amount of anterior mediastinal fat outlined left anterior margin of heart. The statistical studies on roentgen anatomy including the visualization rates of various anatomical structures and the morphological analysis and measurements of various anatomical structures in 300 normal cases. The visualization rates were compared between Japanese and Americans, between age groups over and under 50 years old, and between males and females. The structures which were visualized by the contact with fat or made by fat were more frequently seen in Americans, and the arterial structures were more frequently shown in older people. Other differences were also seen. (J.P.N.)

  15. The adult spinal cord injury without radiographic abnormalities syndrome: magnetic resonance imaging and clinical findings in adults with spinal cord injuries having normal radiographs and computed tomography studies.

    Science.gov (United States)

    Kasimatis, Georgios B; Panagiotopoulos, Elias; Megas, Panagiotis; Matzaroglou, Charalambos; Gliatis, John; Tyllianakis, Minos; Lambiris, Elias

    2008-07-01

    Spinal cord injury without radiographic abnormalities (SCIWORA) is thought to represent mostly a pediatric entity and its incidence in adults is rather underreported. Some authors have also proposed the term spinal cord injury without radiologic evidence of trauma, as more precisely describing the condition of adult SCIWORA in the setting of cervical spondylosis. The purpose of the present study was to evaluate adult patients with cervical spine injuries and radiological-clinical examination discrepancy, and to discuss their characteristics and current management. During a 16-year period, 166 patients with a cervical spine injury were admitted in our institution (Level I trauma center). Upper cervical spine injuries (occiput to C2, 54 patients) were treated mainly by a Halo vest, whereas lower cervical spine injuries (C3-T1, 112 patients) were treated surgically either with an anterior, or posterior procedure, or both. Seven of these 166 patients (4.2%) had a radiologic-clinical mismatch, i.e., they presented with frank spinal cord injury with no signs of trauma, and were included in the study. Magnetic resonance imaging was available for 6 of 7 patients, showing intramedullary signal changes in 5 of 6 patients with varying degrees of compression from the disc and/or the ligamentum flavum, whereas the remaining patient had only traumatic herniation of the intervertebral disc and ligamentum flavum bulging. Follow-up period was 6.4 years on average (1-10 years). This retrospective chart review provides information on adult patients with cervical spinal cord injuries whose radiographs and computed tomography studies were normal. It furthers reinforces the pathologic background of SCIWORA in an adult population, when evaluated by magnetic resonance imaging. Particularly for patients with cervical spondylosis, special attention should be paid with regard to vascular compromise by predisposing factors such as smoking or vascular disease, since they probably contribute in

  16. A protocol for classifying normal- and flat-arched foot posture for research studies using clinical and radiographic measurements

    Directory of Open Access Journals (Sweden)

    Menz Hylton B

    2009-07-01

    Full Text Available Abstract Background There are several clinical and radiological methods available to classify foot posture in research, however there is no clear strategy for selecting the most appropriate measurements. Therefore, the aim of this study was to develop a foot screening protocol to distinguish between participants with normal- and flat-arched feet who would then subsequently be recruited into a series of laboratory-based gait studies. Methods The foot posture of ninety-one asymptomatic young adults was assessed using two clinical measurements (normalised navicular height and arch index and four radiological measurements taken from antero-posterior and lateral x-rays (talus-second metatarsal angle, talo-navicular coverage angle, calcaneal inclination angle and calcaneal-first metatarsal angle. Normative foot posture values were taken from the literature and used to recruit participants with normal-arched feet. Data from these participants were subsequently used to define the boundary between normal- and flat-arched feet. This information was then used to recruit participants with flat-arched feet. The relationship between the clinical and radiographic measures of foot posture was also explored. Results Thirty-two participants were recruited to the normal-arched study, 31 qualified for the flat-arched study and 28 participants were classified as having neither normal- or flat-arched feet and were not suitable for either study. The values obtained from the two clinical and four radiological measurements established two clearly defined foot posture groups. Correlations among clinical and radiological measures were significant (p r = 0.24 to 0.70. Interestingly, the clinical measures were more strongly associated with the radiographic angles obtained from the lateral view. Conclusion This foot screening protocol provides a coherent strategy for researchers planning to recruit participants with normal- and flat-arched feet. However, further research is

  17. Histopathologic changes in soft tissue associated with radiographically normal impacted third molars

    Directory of Open Access Journals (Sweden)

    Kotrashetti Vijayalakshmi

    2010-01-01

    Full Text Available Background: The incidence of impacted or embedded third molars accounts for approximately 98%. Since 1948, there are studies reporting pathological changes in an asymptomatic dental follicle. Controversy still exists for removal of asmptomatic impacted teeth. Hence, this study was performed to histologically evaluate soft tissue pathosis in the pericoronal tissues of impacted third molars with pericoronal radiolucency measuring up to 2.5 mm on orthopantomographs. Materials and Methods: Forty-one asymptomatic impacted third molars with follicular space of up to 2.5 mm on radiographs were included. The disimpacted teeth and the follicular tissues were obtained for histological examination. Results: Age of the patients ranged from 14 to 25 years. Of 41 tissues evaluated, histopathological reports of 18 follicles were suggestive of dentigerous cyst, two follicles showed odontogenic keratocyst, one follicle each of calcifying epithelial odontogenic cyst, ameloblastoma-like proliferation, odontogenic myxoma and odontogenic fibroma. Conclusion: This study showed 58.5% of asymptomatic cases with definite pathological changes. Hence, thorough clinical and radiographic examination should be carried out for all impacted third molars and the dental follicular tissue should be submitted for histopathological evaluation.

  18. Evaluation of computed tomographic and radiographic myelography in normal miniature pigs

    International Nuclear Information System (INIS)

    Choi, M.H.; Lee, H.Y.; Kim, M.E.; Kim, J.Y.; Lee, N.S.; Chang, J.H.; Jung, J.H.; Choi, M.C.

    2010-01-01

    Evaluation of the myelography was studied in miniature pigs. Radiographs and computed tomographic (CT) images of the whole spine were obtained at clinically healthy twelve miniature pigs of 4 (8.7-10 kg) and 12 (26-31 kg) months. The assessments of the spinal cord were made in accordance with the Pavlov's method and compared area ratio [at spinal cord (SC), vertebral canal (VC) and vertebral body (VB)]. The Pavlov's ratio in the cervical spine was significant larger than that of thoracolumbar in radiographic myelography. On CT myelography, the area of the spinal cord had a significant difference between the cervical and thoracolumbar spine. Among the cervical spine, the ratios of spinal cord and vertebral body (SC : VB), vertebral canal and vertebral body (VC : VB) were minimum at the level of 4th cervical spine in both ages, while maximum at the level of 6th cervical spine in both months. In case of lumbar spine, the ratios of spinal cord and vertebral body (SC : VB) were the largest at the level of 4th lumbar spine in 4 months and at the level of 3rd lumbar spine in 12 months. In addition, the ratio of spinal cord and vertebral body (SC : VB) of the cervical spinal cord was significant lower at 4 months but the lumbar spinal cord showed lower pattern at 12 months old miniature pigs

  19. Thoracic and heart biometrics of non-anesthetized agouti (Dasyprocta primnolopha Wagler, 1831 measured on radiographic images

    Directory of Open Access Journals (Sweden)

    Anaemilia das N. Diniz

    2013-03-01

    Full Text Available The agouti is a species intensively hunted throughout the Amazon and the semi-arid regions of northeastern Brazil. Considering the current trend in conservation management of wild species, the aim of this study was to determine the morphometric reference to the heart of agouti raised in captivity, based on thoracic and cardiac measurements in these animals. Thirty adult agoutis, 1 to 3 years of age, without clinical signs of cardiac disease were selected. The animals were physically restrained and radiographies in laterolateral (LL and ventrodorsal (VD recumbence were produced. The following measures were taken: the apicobasilar length of the heart (at the most cranial height of the Carina region to the heart apex (AB, maximum width of the heart perpendicular to AB (CD, heart inclination angle (AIC, trachea inclination angle (AIT, distance from the right heart wall (DPTd, distance from the left heart wall (DPTe and vertical depth of the thorax, and the ventral face of the vertebral column to the dorsal border of the sternum at the level of the trachea bifurcation (H. The ratios between AB/CD, AB/H and CD/H were also analyzed. To calculate the vertebral heart scale (VHS, the AB and CD measurements were laid over the thoracic vertebra starting at T4. Radiographic evaluation showed values consistent with those reported in small animals and some wild and exotic species. The main biometric values in the chest cavity and heart of agouti are arranged as follows: (1 The ratios between AB/H ratio and CD/H were not sensitive for identifying heart increases (p>0.05, while the ratio AB/CD was more sensitive in this identification (p<0.05; (2 AIC: 21.2±6.4º (mean between male and famale; (3 AIT for males and females: 9.93±3.23° and 8.4±3.94°; (4 DPTd and DPTe for males: 0.97±0.40cm and 0.7±0.30cm; (5 DPTd and DPTe for females: 1.12±0.42cm and 01.02±0.43cm; (6 VHS for males and females: 7.75±0.48v e 7.61±0.34v; (7 The caudal vena cava (CVC was

  20. Radiographic examination of the equine foot

    International Nuclear Information System (INIS)

    Park, R.D.

    1989-01-01

    A complete radiographic examination of the equine foot consists of properly exposed, processed, and positioned radiographs. For radiographic interpretation, in addition to knowing radiographic signs of disease, a knowledge of normal radiographic anatomy and possible insignificant anatomic variations is necessary

  1. Upper gastrointestinal examinations: a radiographic study of clinically normal Beagle puppies

    International Nuclear Information System (INIS)

    Miyabayashi, T.; Morgan, J.P.

    1991-01-01

    A total of 24 upper gastrointestinal examinations were performed on four weanling beagle puppies over six weeks, using liquid barium (10 ml/kg body weight of 60 per cent w/v barium sulphate suspension] and barium food (8 g/kg of crushed kibble dog food and 7 ml/kg body weight of 60 per cent w/v barium sulphate suspension) as contrast media. The radiographic appearance was similar to that noted in adult dogs except for the consistent location of the pylorus on or near the midline. Duodenal pseudoulcers were seen more often with liquid barium and the caecal shadows were identified more often with the longer examination time with barium food. The stomach of the puppies appeared to have discriminatory emptying function; that is, semi-solid food was emptied from the stomach at a slower rate (210 to 450 minutes) than liquid (60 to 90 minutes). Solid meals emptied faster in puppies than in adult dogs. Dosages of 13 to 15 mg/kg body weight for the liquid barium examination and 14 g of ground kibble and 16 ml of barium sulphate suspension per m2 of body surface area for the barium food examination are suggested as more appropriate for contrast studies in puppies

  2. Common pitfalls in radiographic interpretation of the Thorax

    International Nuclear Information System (INIS)

    Godshalk, C.P.

    1994-01-01

    Errors in radiographic interpretation of the thorax are common. Many mistakes result from interpreting normal anatomic variants as abnormalstructures, such as misdiagnosing dorsal and rightward deviation of the cranial thoracic trachea on lateral radiographs of normal dogs. Some of the more common errors specifically relate to misinterpretation of radiographs made on obese patients. The age of the patient also plays a role in misdiagnosis. Aging cats seem to have a horizontally positioned heart on lateral radiographs, and older dogs, primarily collies,often have pulmonary osteomas that are misdiagnosed as metastatic neoplastic disease or healed pulmonary fungal infections

  3. Early detection of interstitial pneumonia by WXGa-citrate scintigraphy. Cases of abnormal pulmonary WXGa uptake with normal chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Shinsaku; Mikami, Riichiro; Ryujin, Yoshitada

    1985-04-01

    In this paper we report our recent experience indicating usefulness of WXGa-citrate scintigraphy in 4 cases with inflammatory pulmonary diseases. These cases showed abnormal pulmonary WXGa uptake with normal chest radiographs. The first case with malignant lymphoma and the second one with lung cancer suffered from pulmonary infection following secondary immuno-insufficiency due to radiotherapy and chemotherapy. Pneumocystis carinii was suspected as causative agent in the first case, and gram negative bacilli in the second case. The third case with lung cancer developed radiation pneumonia after radiotherapy. The fourth case with acute bronchitis developed drug induced interstitial pneumonia presumably due to minocycline administration. It is concluded that WXGa-citrate scintigraphy is more sensitive for early detection of interstitial pneumonia than routine chest radiography.

  4. Early Embryonic Heart Rate in Normal Pregnancies In Memory of ...

    African Journals Online (AJOL)

    To determine the appearance and development of embryonic heart rate a total of n = 317 Nigerian pregnant women were studied in the very early pregnancy from 23 – 56 days from the onset of last menstrual period (LMP). All pregnancies had a subsequent successful outcome. Transvaginal ultrasonography was ...

  5. Effects of radiographic contrast media on cellular electrophysiology in the beating heart

    Energy Technology Data Exchange (ETDEWEB)

    Wolpers, H.G.; Baller, D.; Ensink, F.B.M.; Hoeft, A.; Korb, H.; Hellige, G.

    1982-01-01

    Electrophysiological effects of intracoronarily administered contrast media have been documented in 12 thoracotomized dogs at the cellular level by use of a modified microelectrode technique. Injections (n = 63) of 4 different contrast media uniformly led to a temporary cellular hyperpolarisation of the resting potential and prolongation of the action potential. Additional experiments with intracoronary injections of several electrolyte concentrations, mainly by a local deficiency of potassium ions and an excess of sodium ions. The significance of the findings for mechanisms underlying ECG-changes and ventricular arrhythmia by radiographic contrasts media will be discussed.

  6. Bernstein's theory of pedagogic discourse as a theoretical framework for educators studying student radiographers' interpretation of normality vs. abnormality

    International Nuclear Information System (INIS)

    Winter, Peter D.; Linehan, Mark J.

    2014-01-01

    Purpose: To acknowledge the tacit rules underpinning academic practice of undergraduate radiographers in determining normality vs. abnormality when appraising skeletal images. Methodology: Twelve students were interviewed (individually) using in-depth semi-structured questions. Interviews were mediated through a PowerPoint presentation containing two digital X-ray images. Each image was based on a level of expertise; the elementary (Case 1) and the complicated (Case 2). The questions were based on regular ‘frames’ created from observing tutor–student contact in class, and then validated through a group interview. Bernstein's theory of pedagogic discourse was then utilised as a data analysis instrument to determine how third year diagnostic radiography students interpreted X-ray images, in relation to the ‘recognition’ and ‘realisation’ rules of the Educational Theoretical Framework. Conclusion: Bernstein's framework has made it possible to specify, in detail, how issues and difficulties are formed at the level of the acquirer during interpretation. The recognition rules enabled students to meaningfully recognise what trauma characteristics can be associated with the image and the demands of a detailed scrutiny so as to enact a competent interpretation. Realisation rules, made it possible for students to establish their own systematic approach and realise legitimate meanings of normality and abnormality. Whereas obvious or visible trauma generated realisation rules (represented via homogenous terminology), latent trauma authorised students to deviate from legitimate meanings. The latter rule, in this context, has directed attention to the student issue of visioning abnormality when images are normal

  7. Frequency and number of ultrasound lung rockets (B-lines) using a regionally based lung ultrasound examination named vet BLUE (veterinary bedside lung ultrasound exam) in dogs with radiographically normal lung findings.

    Science.gov (United States)

    Lisciandro, Gregory R; Fosgate, Geoffrey T; Fulton, Robert M

    2014-01-01

    Lung ultrasound is superior to lung auscultation and supine chest radiography for many respiratory conditions in human patients. Ultrasound diagnoses are based on easily learned patterns of sonographic findings and artifacts in standardized images. By applying the wet lung (ultrasound lung rockets or B-lines, representing interstitial edema) versus dry lung (A-lines with a glide sign) concept many respiratory conditions can be diagnosed or excluded. The ultrasound probe can be used as a visual stethoscope for the evaluation of human lungs because dry artifacts (A-lines with a glide sign) predominate over wet artifacts (ultrasound lung rockets or B-lines). However, the frequency and number of wet lung ultrasound artifacts in dogs with radiographically normal lungs is unknown. Thus, the primary objective was to determine the baseline frequency and number of ultrasound lung rockets in dogs without clinical signs of respiratory disease and with radiographically normal lung findings using an 8-view novel regionally based lung ultrasound examination called Vet BLUE. Frequency of ultrasound lung rockets were statistically compared based on signalment, body condition score, investigator, and reasons for radiography. Ten left-sided heart failure dogs were similarly enrolled. Overall frequency of ultrasound lung rockets was 11% (95% confidence interval, 6-19%) in dogs without respiratory disease versus 100% (95% confidence interval, 74-100%) in those with left-sided heart failure. The low frequency and number of ultrasound lung rockets observed in dogs without respiratory disease and with radiographically normal lungs suggests that Vet BLUE will be clinically useful for the identification of canine respiratory conditions. © 2014 American College of Veterinary Radiology.

  8. Normal and pathological growth of the foramen occipitale magnum shown in the plain radiograph

    Energy Technology Data Exchange (ETDEWEB)

    Bliesener, J.A.; Schmidt, L.R.

    1980-01-01

    The transverse diameter of the foramen occipitale magnum (f.o.m.) in the semiaxial skull X-ray was measured and evaluated statistically in 174 cerebrally healthy children of different ages. These normal values are contrasted with the foramen diameters of 35 children with verified Arnold-Chiari malformation as well as children with macrocephaly and microcephaly. The values in children with Arnold-Chiari malformation are all above the norm, irrespective of whether or not there is a concomitant hydrocephalus.

  9. The study of shape and size of normal sella turcica in cephalometric radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Wook Jin; Hwang, Eui Hwan; Lee, Sang Rae [Kyung Hee Univ. College of Dentistry, Seoul (Korea, Republic of)

    2001-03-15

    To investigate the shape and size of normal sella turcica on cephalometric radiograms. Cephalometric radiograms of 200 orthodontic patients of age ranging 6-42 years were examined. All subjects were divided into 5 groups by age, the dimensional change of sella turcica was examined according to age, and the configurations of sella turcica floor, tuberculum sella, and anterior and posterior clinoid process were also observed. The contours of sella turcica floor were flat type in 54% and concave type in 46%. The contours of tuberculum sella were right angle type in 55% and obtuse angle type in 44%; Acute angle type and plane type were very rare comprising 0.5%, 0.5% each. The configurations of anterior clinoid process were point type in 80% and round type in 20% of cases, and those of posterior clinoid processes were point type in 60% and round type in 40% of cases. The dimensional change of sella turcica according to age range had significantly positive linear trend to sella turcica length, height, and width until 25 years. After 26 years, no significant increase was found in sella turcica dimension. Especially, the sella turcica length had more proportional increase than that of sella turcica height and width. The results of this study revealed that the configuration of normal sella turcia was variable and the dimensional change of normal sella turcica had a linear tendency with age until 26 years.

  10. Normal and pathological growth of the foramen occipitale magnum shown in the plain radiograph

    International Nuclear Information System (INIS)

    Bliesener, J.A.; Schmidt, L.R.

    1980-01-01

    The transverse diameter of the foramen occipitale magnum (f.o.m.) in the semiaxial skull X-ray was measured and evaluated statistically in 174 cerebrally healthy children of different ages. These normal values are contrasted with the foramen diameters of 35 children with verified Arnold-Chiari malformation as well as children with macrocephaly and microcephaly. The values in children with Arnold-Chiari malformation are all above the norm, irrespective of whether or not there is a concomitant hydrocephalus. (orig.) [de

  11. Automatic heart rate normalization for accurate energy expenditure normalization : an analysis of activities of daily living and heart rate features

    NARCIS (Netherlands)

    Altini, M.; Penders, J.; Vullers, R.J.M.; Amft, O.D.

    2014-01-01

    Introduction: This article is part of the Focus Theme of Methods of Information in Medicine on "Pervasive Intelligent Technologies for Health". Background: Energy Expenditure (EE) estimation algorithms using Heart Rate (HR) or a combination of accelerometer and HR data suffer from large error due to

  12. Standard heart and vessel size on plain films of normal children

    International Nuclear Information System (INIS)

    Stoever, B.

    1986-01-01

    Standards of heart size, i.e. heart diameters and heart volume of normal children aged 4-15 years were obtained. In all cases requiring exact heart size determination, heart volume calculation is mandatory in children as well as in adults. Statistical work to date has provided precise calculation of heart volume plain films in the upright position. Additional plain films in prone position are unnecessary because no evident orthostatic influence on heart volume in children can be found. Percentiles of normal heart volume related to body weight representing the best correlation to the individual data are given as well as percentiles related to age. Furthermore ratios of normal vessel size to the height of the 8sup(th) thoracic vertebral body, measured on the same plain film, are given. In addition the ratio of upper to lower lung vessel size is calculated. These ratios are useful criteria in estimating normal vessel size and also in cases with increased pulmonary venous pressure. (orig.) [de

  13. Extracranial soft-tissue swelling: a normal postmortem radiographic finding or a sign of trauma?

    International Nuclear Information System (INIS)

    Strouse, P.J.; Caplan, M.; Owings, C.L.

    1998-01-01

    Objective. To determine if extracranial soft-tissue swelling is an expected postmortem finding or a sign of trauma. Materials and methods. Extracranial soft-tissue thickness was measured at 5 standardized locations on postmortem skull films obtained of 18 infants with no evidence of trauma on autopsy. The same measurements were performed on the skull films of 100 living children, all less than 3 years old and without clinical history of trauma. Results. Extracranial soft tissues measured only slightly greater in the postmortem group than on films of living children; however, the difference did achieve statistical significance. Conclusion. Minimal extracranial soft-tissue swelling is a normal finding on a postmortem skeletal survey. The presence of substantial or asymmetric extracranial soft-tissue swelling should be viewed with suspicion for trauma. (orig.)

  14. Extracranial soft-tissue swelling: a normal postmortem radiographic finding or a sign of trauma?

    Energy Technology Data Exchange (ETDEWEB)

    Strouse, P.J. [Section of Pediatric Radiology, University of Michigan Medical Center, Ann Arbor (United States); Caplan, M. [Department of Pathology, University of Michigan Medical School, Ann Arbor, Michigan (United States); Owings, C.L. [Department of Pediatrics and Communicable Diseases, C. S. Mott Children`s Hospital, Ann Arbor, Michigan (United States)

    1998-08-01

    Objective. To determine if extracranial soft-tissue swelling is an expected postmortem finding or a sign of trauma. Materials and methods. Extracranial soft-tissue thickness was measured at 5 standardized locations on postmortem skull films obtained of 18 infants with no evidence of trauma on autopsy. The same measurements were performed on the skull films of 100 living children, all less than 3 years old and without clinical history of trauma. Results. Extracranial soft tissues measured only slightly greater in the postmortem group than on films of living children; however, the difference did achieve statistical significance. Conclusion. Minimal extracranial soft-tissue swelling is a normal finding on a postmortem skeletal survey. The presence of substantial or asymmetric extracranial soft-tissue swelling should be viewed with suspicion for trauma. (orig.) With 2 tabs., 5 refs.

  15. Radiographic evaluation of caudal vena cava size as a useful parameter for the diagnosis of heart disease in dairy cattle

    International Nuclear Information System (INIS)

    Jilintai; Hashiyama, S.; Gonda, Y.; Ishikawa, H.; Sato, M.; Miyahara, K.

    2006-01-01

    To quantify the radiographic parameters of the caudal vena cava (CVC) in healthy cattle and demonstrate their clinical usefulness, the present study compared the ratios of the diameter of the thoracic CVC to the diameter of the aorta (Ao) and length of the thoracic vertebrae (VL), which are all positioned in the same intercostal space, in 81 healthy control cattle (43 growing, 38 adult) and 10 cattle with heart disease. The average diameter of the CVC (CVCave) was correlated with the size of the Ao and VL in the control cows. Although the diameter and pulsation index of the CVC differed significantly between the growing and adult cows, the ratios of CVC/Ao and CVC/VL were fixed values for both the growing and mature cattle. However, in the cattle with heart disease, the pulsation index of the CVC was significantly lower or there was absence of pulsation due to a dilated CVC, and the ratio of CVCave/Ao and CVCave/VL were significantly higher than those in the healthy cattle

  16. Heart rate variability in normal-weight patients with polycystic ovary syndrome

    OpenAIRE

    Kilit, Celal; Kilit, T?rkan Pa?al?

    2017-01-01

    Objective: Polycystic ovary syndrome (PCOS) is an endocrine disease closely related to several risk factors of cardiovascular disease. Obese women with PCOS show altered autonomic modulation. The results of studies investigating cardiac autonomic functions of normal-weight women with PCOS are conflicting. The aim of the study was to assess the reactivity of cardiac sympathovagal balance in normal-weight women with PCOS by heart rate variability analysis. Methods: We examined the heart rate va...

  17. Hilar accumulation of gallium-67 in patients with normal chest radiographs

    International Nuclear Information System (INIS)

    Hoshi, Hiroaki; Yamada, Hiroki; Kawahira, Kozaburo; Watanabe, Katsushi

    1982-01-01

    Gallium-67 scintigraphy is a useful screening test to detect malignant or inflammatory lesions. However, the accumulations of Gallium-67 in the normal pulmonary hilum are found in some cases. So, 277 cases with Gallium-67 scintigraphy were discussed. The hilar accumulation of Gallium-67 was classified into four grades, namely Grade 0: no Gallium-67 uptake, Grade I: low Gallium-67 uptake, Grade II: moderate Gallium-67 uptake, and Grade III: high Gallium-67 uptake. Gallium-67 uptake was found in 38 of 277 cases (14%). Thirty cases of these were estimated as Grade I (79%). Cases with Grade II were 20.3%, and only two cases were Grade III (0.7%). Gallium-67 accumulation, was bilateral in 28 cases out of 38 and cases with Gallium-67 accumulation increased with age. Twenty five of the 38 cases with Gallium-67 accumulation had such findings as suggesting old pulmonary inflammation though they had no symptoms of respiratory diseases. This study suggests that hilar Gallium-67 accumulation has no correlation with the active inflammation of the lymphnodes. (author)

  18. Morphometric analysis of three normal facial types in mixed dentition using posteroanterior cephalometric radiographs: preliminary results

    Directory of Open Access Journals (Sweden)

    Renato Bigliazzi

    2017-08-01

    Full Text Available The aim of the present investigation was to evaluate the craniofacial features of subjects with normal occlusion with different vertical patterns in the mixed dentition using morphometric analysis (Thin-Plate Spline analysis - TPS applied to posteroanterior (PA films. The sample comprised 39 individuals (18 females and 21 males, all in mixed dentition, aged from 8.4 to 10 years with satisfactory occlusion and balanced profile and with no history of orthodontic or facial orthopedic treatment. The sample was divided into three groups (mesofacial, brachyfacial and dolichofacial according to the facial types proposed by Ricketts (1989. The average craniofacial configurations of each study group were obtained by orthogonal superimposition of Procrustes, thereby eliminating size differences and allowing only shape differences between groups to be analyzed by viewing the TPS deformation grid. Significant differences were found among the three facial types but were more remarkable between mesofacials and dolichofacials than between mesofacials and brachyfacials. TPS morphometric analysis proved efficient for accurate visualization of transverse and vertical differences among facial types even before pubertal growth spurt. These differences cannot be easily detected by traditional posteroanterior cephalometry.

  19. Evaluation of the radiographic process using a experimental monobath solution compared with normal (Kodak) and rapid (RAY) developer solutions

    International Nuclear Information System (INIS)

    Baratieri, N.M.M.

    1985-01-01

    A comparative evaluation of the radiographic image quality of two dental X-ray films (Kodak's EP-21 and Agfa-Gevaert DOS-1) when processed in a normal (Kodak) a rapid (Ray) and a experimental monobath solutions, is presented. These films, processed in those solutions had their time of development, temperature and agitation performances checked by sensitometry; pH and color by routine methods and hipo rests by spectrophotometry. The radiographies were also analysed by able professionals regarding the best development time. The data so obtained allowed the conclusions that the best development time for the monobath was 3 minutes at 20 0 C but 25 or 30 0 C give also acceptable results at shorter times. The agitation of 10 seconds every minute is an important factor concerning image quality. pH and color do alter rapidally but with little influence in the final result. We found a certain amount of residual chemical compounds which were not identified but that are not hipo components, and being important to note that they seem not act upon the emulsion at least during one year after processing. (author) [pt

  20. Heart rate variability in normal-weight patients with polycystic ovary syndrome.

    Science.gov (United States)

    Kilit, Celal; Paşalı Kilit, Türkan

    2017-05-01

    Polycystic ovary syndrome (PCOS) is an endocrine disease closely related to several risk factors of cardiovascular disease. Obese women with PCOS show altered autonomic modulation. The results of studies investigating cardiac autonomic functions of normal-weight women with PCOS are conflicting. The aim of the study was to assess the reactivity of cardiac sympathovagal balance in normal-weight women with PCOS by heart rate variability analysis. We examined the heart rate variability in 60 normal-weight women with PCOS and compared them with that in 60 age-matched healthy women having a similar metabolic profile. Time and frequency domain parameters of heart rate variability were analyzed based on 5-min-long continuous electrocardiography recordings for the following 3 periods: (1) during rest in supine position, (2) during controlled breathing, and (3) during isometric handgrip exercise. Time and frequency domain parameters of heart rate variability for the 3 periods assessed were similar in the two groups. Although modified Ferriman-Gallwey score and serum testosterone and luteinizing hormone levels were significantly higher in women with PCOS, homeostatic model assessment-insulin resistance (HOMA-IR) was not different the between the PCOS and control groups. There were no significant correlations between serum testosterone levels and heart rate variability parameters among the study population. The findings of this study suggest that the reactivity of cardiac sympathovagal balance is not altered in normal-weight women with PCOS having a normal HOMA-IR.

  1. Cardiovascular cast model fabrication and casting effectiveness evaluation in fetus with severe congenital heart disease or normal heart.

    Science.gov (United States)

    Wang, Yu; Cao, Hai-yan; Xie, Ming-xing; He, Lin; Han, Wei; Hong, Liu; Peng, Yuan; Hu, Yun-fei; Song, Ben-cai; Wang, Jing; Wang, Bin; Deng, Cheng

    2016-04-01

    To investigate the application and effectiveness of vascular corrosion technique in preparing fetal cardiovascular cast models, 10 normal fetal heart specimens with other congenital disease (control group) and 18 specimens with severe congenital heart disease (case group) from induced abortions were enrolled in this study from March 2013 to June 2015 in our hospital. Cast models were prepared by injecting casting material into vascular lumen to demonstrate real geometries of fetal cardiovascular system. Casting effectiveness was analyzed in terms of local anatomic structures and different anatomical levels (including overall level, atrioventricular and great vascular system, left-sided and right-sided heart), as well as different trimesters of pregnancy. In our study, all specimens were successfully casted. Casting effectiveness analysis of local anatomic structures showed a mean score from 1.90±1.45 to 3.60±0.52, without significant differences between case and control groups in most local anatomic structures except left ventricle, which had a higher score in control group (P=0.027). Inter-group comparison of casting effectiveness in different anatomical levels showed no significant differences between the two groups. Intra-group comparison also revealed undifferentiated casting effectiveness between atrioventricular and great vascular system, or left-sided and right-sided heart in corresponding group. Third-trimester group had a significantly higher perfusion score in great vascular system than second-trimester group (P=0.046), while the other anatomical levels displayed no such difference. Vascular corrosion technique can be successfully used in fabrication of fetal cardiovascular cast model. It is also a reliable method to demonstrate three-dimensional anatomy of severe congenital heart disease and normal heart in fetus.

  2. THE EFFECT OF WAIST CIRCUMFERENCES MORE THAN NORMAL ON THE INCIDENT OF CORONARY HEART DISEASE

    Directory of Open Access Journals (Sweden)

    Pria Wahyu

    2017-07-01

    Full Text Available Introduction: Coronary heart disease is known as the most common disease that causes mortality in the world, one of the examination to identify the risks of coronary heart disease is measuring waist circumference. The purpose of this study was to identify correlation between large waist circumferences and the incident of coroner heart disease. Method: Design used in this study was analytic observational (retrospective with cross sectional approach. There were 63 respondents which sampling by simple random sampling. The independent variable was waist circumferences and the dependent variable was coronary heart disease. Data were collected by direct observation then analyzed by spearman correlation statistic test with significance level α≤0.05. Result: The result showed that waist circumferences more than normal had significant correlation with the incident of coronary heart disease (p=0.02. Analysis: It can be concluded that there was correlation between waist circumferences more than normal and the incident of coronary heart disease to the clients with coroner cardiac disease. Discussion: Earlier screening and detection is needed to prevent coronary heart disease.

  3. Normalization of NAD+ Redox Balance as a Therapy for Heart Failure.

    Science.gov (United States)

    Lee, Chi Fung; Chavez, Juan D; Garcia-Menendez, Lorena; Choi, Yongseon; Roe, Nathan D; Chiao, Ying Ann; Edgar, John S; Goo, Young Ah; Goodlett, David R; Bruce, James E; Tian, Rong

    2016-09-20

    Impairments of mitochondrial function in the heart are linked intricately to the development of heart failure, but there is no therapy for mitochondrial dysfunction. We assessed the reduced/oxidized ratio of nicotinamide adenine dinucleotide (NADH/NAD(+) ratio) and protein acetylation in the failing heart. Proteome and acetylome analyses were followed by docking calculation, mutagenesis, and mitochondrial calcium uptake assays to determine the functional role of specific acetylation sites. The therapeutic effects of normalizing mitochondrial protein acetylation by expanding the NAD(+) pool also were tested. Increased NADH/NAD(+) and protein hyperacetylation, previously observed in genetic models of defective mitochondrial function, also are present in human failing hearts as well as in mouse hearts with pathologic hypertrophy. Elevation of NAD(+) levels by stimulating the NAD(+) salvage pathway suppressed mitochondrial protein hyperacetylation and cardiac hypertrophy, and improved cardiac function in responses to stresses. Acetylome analysis identified a subpopulation of mitochondrial proteins that was sensitive to changes in the NADH/NAD(+) ratio. Hyperacetylation of mitochondrial malate-aspartate shuttle proteins impaired the transport and oxidation of cytosolic NADH in the mitochondria, resulting in altered cytosolic redox state and energy deficiency. Furthermore, acetylation of oligomycin-sensitive conferring protein at lysine-70 in adenosine triphosphate synthase complex promoted its interaction with cyclophilin D, and sensitized the opening of mitochondrial permeability transition pore. Both could be alleviated by normalizing the NAD(+) redox balance either genetically or pharmacologically. We show that mitochondrial protein hyperacetylation due to NAD(+) redox imbalance contributes to the pathologic remodeling of the heart via 2 distinct mechanisms. Our preclinical data demonstrate a clear benefit of normalizing NADH/NAD(+) imbalance in the failing hearts

  4. 3D imaging of the mitochondrial redox state of rat hearts under normal and fasting conditions

    Directory of Open Access Journals (Sweden)

    He N. Xu

    2014-03-01

    Full Text Available The heart requires continuous ATP availability that is generated in the mitochondria. Although studies using the cell culture and perfused organ models have been carried out to investigate the biochemistry in the mitochondria in response to a change in substrate supply, mitochondrial bioenergetics of heart under normal feed or fasting conditions has not been studied at the tissue level with a sub-millimeter spatial resolution either in vivo or ex vivo. Oxidation of many food-derived metabolites to generate ATP in the mitochondria is realized through the NADH/NAD+ couple acting as a central electron carrier. We employed the Chance redox scanner — the low-temperature fluorescence scanner to image the three-dimensional (3D spatial distribution of the mitochondrial redox states in heart tissues of rats under normal feeding or an overnight starvation for 14.5 h. Multiple consecutive sections of each heart were imaged to map three redox indices, i.e., NADH, oxidized flavoproteins (Fp, including flavin adenine dinucleotide (FAD and the redox ratio NADH/Fp. The imaging results revealed the micro-heterogeneity and the spatial distribution of these redox indices. The quantitative analysis showed that in the fasted hearts the standard deviation of both NADH and Fp, i.e., SD_NADH and SD_Fp, significantly decreased with a p value of 0.032 and 0.045, respectively, indicating that the hearts become relatively more homogeneous after fasting. The fasted hearts contained 28.6% less NADH (p = 0.038. No significant change in Fp was found (p = 0.4. The NADH/Fp ratio decreased with a marginal p value (0.076. The decreased NADH in the fasted hearts is consistent with the cardiac cells' reliance of fatty acids consumption for energy metabolism when glucose becomes scarce. The experimental observation of NADH decrease induced by dietary restriction in the heart at tissue level has not been reported to our best knowledge. The Chance redox scanner demonstrated the

  5. 3D IMAGING OF THE MITOCHONDRIAL REDOX STATE OF RAT HEARTS UNDER NORMAL AND FASTING CONDITIONS.

    Science.gov (United States)

    Xu, He N; Zhou, Rong; Moon, Lily; Feng, Min; Li, Lin Z

    2014-03-01

    The heart requires continuous ATP availability that is generated in the mitochondria. Although studies using the cell culture and perfused organ models have been carried out to investigate the biochemistry in the mitochondria in response to a change in substrate supply, mitochondrial bioenergetics of heart under normal feed or fasting conditions has not been studied at the tissue level with a sub-millimeter spatial resolution either in vivo or ex vivo . Oxidation of many food-derived metabolites to generate ATP in the mitochondria is realized through the NADH/NAD + couple acting as a central electron carrier. We employed the Chance redox scanner - the low-temperature fluorescence scanner to image the three-dimensional (3D) spatial distribution of the mitochondrial redox states in heart tissues of rats under normal feeding or an overnight starvation for 14.5 h. Multiple consecutive sections of each heart were imaged to map three redox indices, i.e., NADH, oxidized flavoproteins (Fp, including flavin adenine dinucleotide (FAD)) and the redox ratio NADH/Fp. The imaging results revealed the micro-heterogeneity and the spatial distribution of these redox indices. The quantitative analysis showed that in the fasted hearts the standard deviation of both NADH and Fp, i.e., SD_NADH and SD_Fp, significantly decreased with a p value of 0.032 and 0.045, respectively, indicating that the hearts become relatively more homogeneous after fasting. The fasted hearts contained 28.6% less NADH ( p = 0.038). No significant change in Fp was found ( p = 0.4). The NADH/Fp ratio decreased with a marginal p value (0.076). The decreased NADH in the fasted hearts is consistent with the cardiac cells' reliance of fatty acids consumption for energy metabolism when glucose becomes scarce. The experimental observation of NADH decrease induced by dietary restriction in the heart at tissue level has not been reported to our best knowledge. The Chance redox scanner demonstrated the feasibility of 3D

  6. Multivariate Normal Tissue Complication Probability Modeling of Heart Valve Dysfunction in Hodgkin Lymphoma Survivors

    International Nuclear Information System (INIS)

    Cella, Laura; Liuzzi, Raffaele; Conson, Manuel; D’Avino, Vittoria; Salvatore, Marco; Pacelli, Roberto

    2013-01-01

    Purpose: To establish a multivariate normal tissue complication probability (NTCP) model for radiation-induced asymptomatic heart valvular defects (RVD). Methods and Materials: Fifty-six patients treated with sequential chemoradiation therapy for Hodgkin lymphoma (HL) were retrospectively reviewed for RVD events. Clinical information along with whole heart, cardiac chambers, and lung dose distribution parameters was collected, and the correlations to RVD were analyzed by means of Spearman's rank correlation coefficient (Rs). For the selection of the model order and parameters for NTCP modeling, a multivariate logistic regression method using resampling techniques (bootstrapping) was applied. Model performance was evaluated using the area under the receiver operating characteristic curve (AUC). Results: When we analyzed the whole heart, a 3-variable NTCP model including the maximum dose, whole heart volume, and lung volume was shown to be the optimal predictive model for RVD (Rs = 0.573, P<.001, AUC = 0.83). When we analyzed the cardiac chambers individually, for the left atrium and for the left ventricle, an NTCP model based on 3 variables including the percentage volume exceeding 30 Gy (V30), cardiac chamber volume, and lung volume was selected as the most predictive model (Rs = 0.539, P<.001, AUC = 0.83; and Rs = 0.557, P<.001, AUC = 0.82, respectively). The NTCP values increase as heart maximum dose or cardiac chambers V30 increase. They also increase with larger volumes of the heart or cardiac chambers and decrease when lung volume is larger. Conclusions: We propose logistic NTCP models for RVD considering not only heart irradiation dose but also the combined effects of lung and heart volumes. Our study establishes the statistical evidence of the indirect effect of lung size on radio-induced heart toxicity

  7. Prolonged Tp-e Interval in Down Syndrome Patients with Congenitally Normal Hearts.

    Science.gov (United States)

    Kucuk, Mehmet; Karadeniz, Cem; Ozdemir, Rahmi; Meşe, Timur

    2018-03-25

    Heterogeneity of ventricular repolarization has been assessed by using the QT dispersion in Down syndrome (DS) patients with congenitally normal hearts. However, novel repolarization indexes, the Tp-e interval and Tp-e/QT ratio, have not previously been evaluated in these patients. The aim of this study was to evaluate the Tp-e interval and Tp-e/QT ratio in DS patients without congenital heart defects. Twelve-lead surface electrocardiograms of 160 DS patients and 110 age- and sex-matched healthy controls were used to evaluate and compare the Tp-e interval, Tp-e dispersion, and Tp-e/QT ratio. Heart rate, Tp-e interval, Tp-e dispersion, Tp-e/QT and Tp-e/QTc ratios were significantly higher in DS group than in the controls. Myocardial repolarization indexes in DS patients with congenitally normal hearts were found to be prolonged compared to those in normal controls. Further evaluation is warranted to reveal a relationship between prolonged repolarization indexes and arrhythmic events in these patients. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Catecholaminergic polymorphic ventricular tachycardia. An important diagnosis in children with syncope and normal heart

    Directory of Open Access Journals (Sweden)

    Luiz Roberto Leite

    2001-01-01

    Full Text Available Syncope in children is primarily related to vagal hyperreactivity, but ventricular tachycardia (VT way rarely be seen. Catecholaminergic polymorphic VT is a rare entity that can occur in children without heart disease and with a normal QT interval, which may cause syncope and sudden cardiac death. In this report, we describe the clinical features, treatment, and clinical follow-up of three children with syncope associated with physical effort or emotion and cathecolaminergic polymorphic VT. Symptoms were controlled with beta-blockers, but one patient died suddenly in the fourth year of follow-up. Despite the rare occurrence, catecholaminergic polymorphic VT is an important cause of syncope and sudden death in children with no identified heart disease and normal QT interval.

  9. [Estimation of the atrioventricular time interval by pulse Doppler in the normal fetal heart].

    Science.gov (United States)

    Hamela-Olkowska, Anita; Dangel, Joanna

    2009-08-01

    To assess normative values of the fetal atrioventricular (AV) time interval by pulse-wave Doppler methods on 5-chamber view. Fetal echocardiography exams were performed using Acuson Sequoia 512 in 140 singleton fetuses at 18 to 40 weeks of gestation with sinus rhythm and normal cardiac and extracardiac anatomy. Pulsed Doppler derived AV intervals were measured from left ventricular inflow/outflow view using transabdominal convex 3.5-6 MHz probe. The values of AV time interval ranged from 100 to 150 ms (mean 123 +/- 11.2). The AV interval was negatively correlated with the heart rhythm (page of gestation (p=0.007). However, in the same subgroup of the fetal heart rate there was no relation between AV intervals and gestational age. Therefore, the AV intervals showed only the heart rate dependence. The 95th percentiles of AV intervals according to FHR ranged from 135 to 148 ms. 1. The AV interval duration was negatively correlated with the heart rhythm. 2. Measurement of AV time interval is easy to perform and has a good reproducibility. It may be used for the fetal heart block screening in anti-Ro and anti-La positive pregnancies. 3. Normative values established in the study may help obstetricians in assessing fetal abnormalities of the AV conduction.

  10. Cephalometric-radiographic study, in lateral norm, considering the established standards of white Brazilian teenagers who presented normal occlusions and mal-occlusions of Class I and Class II, 1st Division and the ones from Ricketts' analysis

    International Nuclear Information System (INIS)

    Bismarck, V.E.

    1986-01-01

    In the present work, our purpose was make a cephalometric-radiographic study, comparing white Brazilian teenagers who presented normal occlusion and the ones who presented malocclusions of Class I and Class II, according to RICKETT'S analysis (1960). (author) [pt

  11. Factors related to outcome in heart failure with a preserved (or normal) left ventricular ejection fraction.

    Science.gov (United States)

    Sanderson, John E

    2016-07-01

    Heart failure with a preserved ejection faction (HFpEF) is a growing and expensive cause of heart failure (HF) affecting particularly the elderly. It differs in substantial ways in addition to the normal left ventricular ejection fraction, from the more easily recognized form of heart failure with a reduced ejection fraction (HFrEF or 'systolic heart failure') and unlike HFrEF there have been little advances in treatment. In part, this relates to the complexity of the pathophysiology and identifying the correct targets. In HFpEF, there appears to be widespread stiffening of the vasculature and the myocardium affecting ventricular function (both systolic and diastolic), impeding ventricular suction, and thus early diastolic filling leading to breathlessness on exertion and later atrial failure and fibrillation. Left ventricular ejection fraction tends to gradually decline and some evolve into HFrEF. Most patients also have a mixture of several co-morbidities including hypertension, diabetes, obesity, poor renal function, lack of fitness, and often poor social conditions. Therefore, many factors may influence outcome in an individual patient. In this review, the epidemiology, possible causation, pathophysiology, the influence of co-morbidities and some of the many potential predictors of outcome will be considered.

  12. Application of digital tomosynthesis to radiographic diagnosis of the temporal bone. Studies on visualization in normal subjects

    International Nuclear Information System (INIS)

    Kawai, Takashi

    1995-01-01

    To examine the usefulness of digital tomosynthesis for conducting radiographic diagnosis of the temporal bone, visualization of various aural structures such as the semicircular canals, cochlea, vestibular apparatus, ossicles of the ear and facial nerve canal was examined in 18 volunteers. The visualization of temporal bone specimens by digital tomosynthesis and CT images (slice thickness: 1.5 mm) was compared. The results showed that this system (Digital Tomosynthesis) produced clear images of bony labyrinthine structures such as the semicircular canals, cochlea, and vestibular apparatus. Visualization of the ossicles was also clear, and their continuity could be comprehended better than on CT images. This system also provided good visualization of the labyrinthine and tympanic parts of the facial nerve canal, although CT images had greater sharpness. Visualization of the lower half of the mastoid part was poor with this system. (author)

  13. Prognostic significance of hemoglobin level in patients with congestive heart failure and normal ejection fraction.

    Science.gov (United States)

    Varadarajan, Padmini; Gandhi, Siddharth; Sharma, Sanjay; Umakanthan, Branavan; Pai, Ramdas G

    2006-10-01

    Previous studies have shown low hemoglobin (Hb) to have an adverse effect on survival in patients with congestive heart failure (CHF) and reduced left ventricular (LV) ejection fraction (EF); but its effect on survival in patients with CHF and normal EF is not known. This study sought to determine whether low Hb has an effect on survival in patients with both CHF and normal EF. Detailed chart reviews were performed by medical residents on 2,246 patients (48% with normal EF) with a discharge diagnosis of CHF in a large tertiary care hospital from 1990 to 1999. The CHF diagnosis was validated using the Framingham criteria. Mortality data were obtained from the National Death Index. Survival analysis was performed using Kaplan-Meier and Cox regression models. By Kaplan-Meier analysis, low Hb (< 12 gm/dl) compared with normal hemoglobin was associated with a lower 5-year survival in patients with CHF and both normal (38 vs. 50%, p = 0.0008) and reduced (35 vs. 48%, p = 0.0009) EF. Using the Cox regression model, low Hb was an independent predictor of mortality after adjusting for age, gender, renal dysfunction, diabetes mellitus, hypertension, and EF in both groups of patients. Low Hb has an independent adverse effect on survival in patients with CHF and both normal and reduced EF in both groups of patients.

  14. Influence of peak exercise heart rate on normal thallium-201 myocardial clearance

    International Nuclear Information System (INIS)

    Kaul, S.; Chesler, D.A.; Pohost, G.M.; Strauss, H.W.; Okada, R.D.; Boucher, C.A.

    1986-01-01

    Measurement of myocardial clearance rates between initial and delayed images is a major justification for adding computer quantification to the interpretation of exercise 201 TI images. To clarify the range of normal thallium clearance and its relationship to the level of exercise achieved, exercise thallium images in 89 normal subjects were analyzed: 45 asymptomatic subjects with less than 1% probability of coronary artery disease (CAD) (Group I), and 44 patients with chest pain found to have no significant CAD on angiography (Group II). Mean initial regional thallium uptake was similar in the two groups, but myocardial thallium clearance (mean +/- 1 s.d.) was slower in Group II, expressed as a longer half-life in the myocardium (8.2 +/- 7.6 hr compared with 3.4 +/- 0.7 hr p less than 0.001). Analysis of variance using ten clinical and exercise variables as covariates showed that the slower clearance in Group II was related to a lower peak exercise heart rate (HR) (154 +/- 27 compared with 183 +/- 11, respectively, p less than 0.001). By linear regression analysis, a decrease in peak HR of 1 beat/min was associated with a slower thallium clearance (longer half-life) of 0.05 hr. Using this formula, the clearance value in each patient was then corrected for peak exercise heart rate by decreasing measured clearance by 0.05 hr multiplied by the amount peak exercise heart rate which was below 183 (the mean value in Group I). There were no differences in the corrected clearance between the two groups. We conclude that thallium myocardial clearance after exercise is related in part to factors other than the presence of CAD, being slower when peak exercise HR is lower. Therefore, thallium clearance rates alone uncorrected for peak exercise heart rate should be used with caution when diagnosing CAD

  15. Oral triiodothyronine normalizes triiodothyronine levels after surgery for pediatric congenital heart disease*.

    Science.gov (United States)

    Marwali, Eva M; Boom, Cindy E; Sakidjan, Indriwanto; Santoso, Anwar; Fakhri, Dicky; Kartini, Ay; Kekalih, Aria; Schwartz, Steven M; Haas, Nikolaus A

    2013-09-01

    This study was conducted to determine if oral triiodothyronine supplementation could prevent the decrease of serum triiodothyronine levels that commonly occurs after cardiopulmonary bypass for pediatric congenital heart surgery. Secondary objectives included identifying any significant adverse effects of oral triiodothyronine supplementation, including any effects on the thyroid/pituitary axis. Randomized, placebo-controlled, doubleblind clinical trial Operating room and ICU. Infants and children younger than 2 years of age undergoing congenital heart surgery using cardiopulmonary bypass (n = 43). Subjects were assigned to placebo (n = 15, group A) or one of two treatment groups: a low-dose group (group B, n = 14, 0.5 mcg/kg triiodothyronine orally every 24 hr for 3 d) or a high-dose group (group C, n = 14, 0.5 mcg/kg triiodothyronine orally every 12 hr for 3 d). Thyroid hormone, including total and free triiodothyronine levels at predetermined time points, potential side effects indicating hyperthyroidism, indicators of the thyroid-pituitary axis, and clinical endpoints. Oral triiodothyronine supplementation twice-daily maintained serum triiodothyronine levels within normal limits in group C, whereas serum levels progressively declined in groups A and B. A statistically significant difference in triiodothyronine levels between the treatment groups occurred between 18 and 36 hours post cross-clamp release, with the largest difference in serum levels between group C and group A noted at 36 hours post cross-clamp release (total triiodothyronine, 0.71 ± 0.15 [0.34-1.08] ng/mL [p triiodothyronine, 2.56 ± 0.49 [1.33-3.79] pg/mL [p triiodothyronine supplementation at a dose of 0.5 mcg/kg every 12 hours for 3 days can maintain total and free triiodothyronine levels within normal limits after open-heart surgery using cardiopulmonary bypass for congenital heart disease.

  16. Partial LVAD restores ventricular outputs and normalizes LV but not RV stress distributions in the acutely failing heart in silico

    OpenAIRE

    Sack, Kevin L.; Baillargeon, Brian; Acevedo-Bolton, Gabriel; Genet, Martin; Rebelo, Nuno; Kuhl, Ellen; Klein, Liviu; Weiselthaler, Georg M.; Burkhoff, Daniel; Franz, Thomas; Guccione, Julius M.

    2016-01-01

    Purpose: Heart failure is a worldwide epidemic that is unlikely to change as the population ages and life expectancy increases. We sought to detail significant recent improvements to the Dassault Systèmes Living Heart Model (LHM) and use the LHM to compute left ventricular (LV) and right ventricular (RV) myofiber stress distributions under the following 4 conditions: (1) normal cardiac function; (2) acute left heart failure (ALHF); (3) ALHF treated using an LV assist device (LVAD) flow rate o...

  17. Sex Dimorphism of the Heart Diameters and Cardiothoracic Ratios ...

    African Journals Online (AJOL)

    Objective: To determine gender associated differences in the cardiothoracic ratio (CTR) and heart diameters in a normal Nigerian population. Subject and Method: The normal heart diameters and cardiothoracic ratios were measured from posteroanterior (PA) chest radiographs of healthy 510 male and 508 female ...

  18. CARDIOTHORACIC RATIO AND VERTEBRAL HEART SCALE IN CLINICALLY NORMAL BLACK-RUMPED AGOUTIS (DASYPROCTA PRYMNOLOPHA, WAGLER 1831).

    Science.gov (United States)

    de Moura, Charlys Rhands Coelho; das Neves Diniz, Anaemilia; da Silva Moura, Laecio; das Chagas Araújo Sousa, Francisco; Baltazar, Pollyana Irene; Freire, Larisse Danielle; Guerra, Porfírio Candanedo; de Sousa, João Macedo; Giglio, Robson Fortes; Pessoa, Gerson Tavares; de Sá, Renan Paraguassu; Alves, Flávio Ribeiro

    2015-06-01

    Wild rodents, such as the lowland paca (Cuniculus paca), capybara (Hydrochoerus hydrochaeris), rock cavy (Kerodon rupestris), guinea pig (Cavia aperea), and black-rumped agouti (Dasyprocta prymnolopha) are intensely hunted throughout Amazonia and at the semiarid regions of northeastern Brazil. To contribute to the preservation of these species, more information about their anatomy, physiology and pathophysiology is needed. The aim of this study was to standardize the vertebral heart scale (VHS) and cardiothoracic ratio (CTR) in clinically normal black-rumped agouti, as well as to compare the results of these two methods, which are commonly used to evaluate the cardiac silhouette in domestic animals. Twelve healthy black-rumped agoutis, divided into two groups (six males and six females), obtained from the Nucleus for Wild Animal Studies and Conservation at the Federal University of Piauí, were radiographed in right and left lateral and dorsoventral projections. The values of the VHS were 8.00±0.31v (the number of thoracic vertebral length spanned by each dimension, starting at T4) for males and 8.11±0.41v for females, and there was no statistical difference between the decubitus (right and left) or between males and females (P>0.05). The CTR mean values obtained were 0.51±0.03 for males, and 0.52±0.02 for females, and there was no statistical difference between the genders (P>0.05). However, there was positive correlation between VHS and CTR (r=0.77 right decubitus and r=0.82 left decubitus). The thoracic and heart diameter had mean values of 6.72±0.61 and 3.48±0.30 cm (males), and for the females, it was 6.61±0.51 and 3.5±0.30 cm, respectively, and there was statistical difference between the genders. The results demonstrated high correlation between the VHS and CTR producing similar results, indicating similar clinical precision for assessing the size of the cardiac silhouette in the black-rumped agoutis.

  19. Impact of age and sex on normal left heart structure and function.

    Science.gov (United States)

    Hagström, Linn; Henein, Michael Y; Karp, Kjell; Waldenström, Anders; Lindqvist, Per

    2017-11-01

    Accurate age- and sex-related normal reference values of ventricular structure and function are important to determine the level of dysfunction in patients. The aim of this study therefore was to document normal age range sex-related measurements of LV structural and functional measurements to serve such purpose. We evaluated left ventricular structure and function in 293 healthy subjects between 20 and 90 years with equally distributed gender. Doppler echocardiography was used including measure of both systolic and diastolic functions. Due to systolic LV function, only long axis function correlated with age (r = 0·55, P<0·01) and the correlation was stronger in females. Concerning diastolic function, there was a strong age correlation in all parameters used (r = 0·40-0·74, P<0·001). Due to LV structural changes over age, females showed a larger reduction in end-diastolic volumes, but no or trivial difference in wall thickness after the age of 60 years. Age is associated with significant normal changes in left ventricular structure and function, which should be considered when deciding on normality. These changes are related to systemic arterial changes as well as body stature, thus reflecting overall body ageing process. Furthermore, normal cardiac ageing in females might partly explain the higher prevalence of heart failure with preserved ejection in females. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  20. Pulmonary edema: radiographic differential diagnosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo; Choi, Young Hi; Kim, Seung Cheol; An, Ji Hyun; Lee, Jee Young; Park, Hee Hong

    1997-01-01

    To evaluate the feasibility of using chest radiography to differentiate between three different etiologies of pulmonary edema. Plain chest radiographs of 77 patients, who were clinically confirmed as having pulmonary edema, were retrospectively reviewed. The patients were classified into three groups : group 1 (cardiogenic edema : n = 35), group 2 (renal pulmonary edema : n = 16) and group 3 (permeability edema : n = 26). We analyzed the radiologic findings of air bronchogram, heart size, peribronchial cuffing, septal line, pleural effusion, vascular pedicle width, pulmonary blood flow distribution and distribution of pulmonary edema. In a search for radiologic findings which would help in the differentiation of these three etiologies, each finding was assessed. Cardiogenic and renal pulmonary edema showed overlapping radiologic findings, except for pulmonary blood flow distribution. In cardiogenic pulmonary edema (n=35), cardiomegaly (n=29), peribronchial cuffing (n=29), inverted pulmonary blood flow distribution (n=21) and basal distribution of edema (n=20) were common. In renal pulmonary edema (n=16), cardiomegaly (n=15), balanced blood flow distribution (n=12), and central (n=9) or basal distribution of edema (n=7) were common. Permeability edema (n=26) showed different findings. Air bronchogram (n=25), normal blood flow distribution (n=14) and peripheral distribution of edema (n=21) were frequent findings, while cardiomegaly (n=7), peribronchial cuffing (n=7) and septal line (n=5) were observed in only a few cases. On plain chest radiograph, permeability edema can be differentiated from cardiogenic or renal pulmonary edema. The radiographic findings which most reliably differentiated these two etiologies were air bronchogram, distribution of pulmonary edema, peribronchial cuffing and heart size. Only blood flow distribution was useful for radiographic differentiation of cardiogenic and renal edema

  1. Profile of Cardiovascular Risk Factors in Patients with Coronary Heart Disease, Normal and Impaired Carbohydrate Metabolism

    Directory of Open Access Journals (Sweden)

    І.V. Cherniavska

    2015-11-01

    Full Text Available The aim of research was to conduct the comparative analysis of the profile of cardiovascular risk factors in patients with coronary heart disease (CHD and normal either impaired carbohydrate metabolism. Materials and methods. One hundred and forty two patients were observed. In order to estimate the rate of different forms of CHD depending on the state of carbohydrate metabolism such groups were formed: the first group consisted of 83 patients with type 2 diabetes mellitus (DM, the second group involved 34 patients with impaired glucose tolerance (IGT, the third group consisted of 25 patients with normal carbohydrate metabolism. The ischemic changes of myocardium were detected by ambulatory ECG monitoring with the obligatory achievement of submaximal heart rate during the research. Results. Silent myocardial ischemia was educed in 19 (22.9 % patients with type 2 DM, in 3 (8.8 % persons with IGT and in 2 (8.0 % patients with normal carbohydrate metabolism. Smoking, burdened heredity, violation in the haemostatic system more often occurred in the group of patients with type 2 DM and silent myocardial ischemia in comparison with the patients with type 2 DM without CHD. The profile of general population cardiovascular risk factors in patients with CHD and type 2 DM belongs to the most unfavorable. At the same time for patients with early violations of carbohydrate metabolism and normal carbohydrate metabolism such profile statistically does not differentiate meaningfully. Conclusions. Patients with type 2 DM and silent myocardial ischemia as compared to patients with type 2 DM without CHD have more expressed violations of indexes of general population cardiovascular risk factors for certain.

  2. Anatomy of the normal fetal heart: The basis for understanding fetal echocardiography

    Directory of Open Access Journals (Sweden)

    Beatriz Picazo-Angelin

    2018-01-01

    Full Text Available The rapid changes that have taken place in recent years in relation to techniques used to image the fetal heart have emphasized the need to have a detailed knowledge ofnormal cardiac anatomy. Without such knowledge, it is difficult, if not impossible, to recognize the multiple facets of congenital cardiac disease. From the inception of fetal echocardiographic screening, the importance of basic knowledge of cardiac anatomy has been well recognized. The current machines used for imaging, however, now make it possible potentially to recognize features not appreciated at the start of the specialty. So as to match the advances made in imaging, we have now revisited our understanding of normal cardiac anatomy in the mid-gestational fetus. This was made possible by our dissection of 10 fetal hearts, followed by production of addition histological sections that mimic the standard ultrasound views. The fetuses ranged in gestational age from between 20 and 28 weeks. We then correlated the obtained anatomic images with the corresponding ultrasonic images used in the standard fetal screening scan. We also interrogated the anatomic sections so as to clarify ongoing controversies regarding detailed features of the normal cardiac anatomy. We have been able to show that the views now obtained using current technology reveal many details of anatomy not always appreciated at earlier times. Knowledge of these features should now permit diagnosis of most congenital cardiac malformations. The anatomic-echocardiographic correlations additionally provide a valuable resource for both the understanding and teaching of fetal echocardiography.

  3. Radiographic evaluation of the cardiac silluet using the VHS method (Vertebral Heart Size in young and adults coatis (Nasua nasua, Linneaus 1766 living in captivity

    Directory of Open Access Journals (Sweden)

    Andresa Cássia Martini

    2014-02-01

    Full Text Available Radiographic examination of the toracic cavity is an usefull noninvasive method for assessment, monitoring the progress of heart disease, suggesting prognosis and guiding the treatment. The aim of this study was to evaluate the cardiac silhouette of young and adults coatis and evaluate its relationship to the number of thoracic vertebrae (VHS, the method proposed by Buchanam and Buchele (1995 for small animals. We evaluated a group of 20 coatis, divided by age: I (GI and 8 animals aged between 4 and 5 months and group II (GII with 12 animals over 12 months old. Based in chest radiographs and VD laterolateral right projections for determining the major axis (L and short axis (Y being the sum of L and S is the value obtained by ESR, the relative depth/width (D / L chest were obtained and the results determined the type of conformation of the thorax, which results greater than 1.25 cm denote chest type deep, 0.75 to 1.25 cm chest intermediate and inferior results will 0.75cm wide chest. It was observed that the heart is alocated between the fourth and seventh pair of ribs, VHS average coatis healthy adults was 9.36 ± 0.75 and 8.06 ± 0 youth, 595 units thoracic vertebrae and the predominant conformation found was of intermediate type when compared to dogs. The mean values in this study serve as a basis for interpretation of the VHS type, however, a larger number may be required animals to determine the physiological limits of the cardiac silhouette in coati.

  4. Quantification of pulmonary thallium-201 activity after upright exercise in normal persons: importance of peak heart rate and propranolol usage in defining normal values

    International Nuclear Information System (INIS)

    Brown, K.A.; Boucher, C.A.; Okada, R.D.; Strauss, H.W.; Pohost, G.M.

    1984-01-01

    Fifty-nine normal patients (34 angiographically normal and 25 clinically normal by Bayesian analysis) underwent thallium-201 imaging after maximal upright exercise. Lung activity was quantitated relative to myocardial activity and a lung/myocardial activity ratio was determined for each patient. Stepwise regression analysis was then used to examine the influence of patient clinical characteristics and exercise variables on the lung/myocardium ratio. Peak heart rate during exercise and propranolol usage both showed significant negative regression coefficients (p less than 0.001). No other patient data showed a significant relation. Using the regression equation and the estimated variance, a 95% confidence level upper limit of normal could be determined for a give peak heart rate and propranolol status. Sixty-one other patients were studied to validate the predicted upper limits of normal based on this model. None of the 27 patients without coronary artery disease had an elevated lung/myocardial ratio, compared with 1 of 8 with 1-vessel disease (difference not significant), 6 of 14 with 2-vessel disease (p less than 0.005), and 6 of 12 with 3-vessel disease (p less than 0.0001). Thus, lung activity on upright exercise thallium-201 studies can be quantitated relative to myocardial activity, and is inversely related to peak heart rate and propranolol use. Use of a regression analysis allows determination of a 95% confidence upper limit of normal to be anticipated in an individual patient

  5. Systolic Strain Abnormalities to Predict Hospital Readmission in Patients With Heart Failure and Normal Ejection Fraction

    Science.gov (United States)

    Borer, Steven M.; Kokkirala, Aravind; O'Sullivan, David M.; Silverman, David I.

    2011-01-01

    Background Despite intensive investigation, the pathogenesis of heart failure with normal ejection fraction (HFNEF) remains unclear. We hypothesized that subtle abnormalities of systolic function might play a role, and that abnormal systolic strain and strain rate would provide a marker for adverse outcomes. Methods Patients of new CHF and left ventricular ejection fraction > 50% were included. Exclusion criteria were recent myocardial infarction, severe valvular heart disease, severe left ventricular hypertrophy (septum >1.8 cm), or a technically insufficient echocardiogram. Average peak systolic strain and strain rate were measured using an off-line grey scale imaging technique. Systolic strain and strain rate for readmitted patients were compared with those who remained readmission-free. Results One hundred consecutive patients with a 1st admission for HFNEF from January 1, 2004 through December 31, 2007, inclusive, were analyzed. Fifty two patients were readmitted with a primary diagnosis of heart failure. Systolic strain and strain rates were reduced in both study groups compared to controls. However, systolic strain did not differ significantly between the two groups (-11.7% for those readmitted compared with -12.9% for those free from readmission, P = 0.198) and systolic strain rates also were similar (-1.05 s-1 versus -1.09 s-1, P = 0.545). E/e’ was significantly higher in readmitted patients compared with those who remained free from readmission (14.5 versus 11.0, P = 0.013). E/e’ (OR 1.189, 95% CI 1.026-1.378; P = 0.021) was found to be an independent predictor for HFNEF readmission. Conclusions Among patients with new onset HFNEF, SS and SR rates are reduced compared with patients free of HFNEF, but do not predict hospital readmission. Elevated E/e’ is a predictor of readmission in these patients. PMID:28352395

  6. Potential fields on the ventricular surface of the exposed dog heart during normal excitation.

    Science.gov (United States)

    Arisi, G; Macchi, E; Baruffi, S; Spaggiari, S; Taccardi, B

    1983-06-01

    We studied the normal spread of excitation on the anterior and posterior ventricular surface of open-chest dogs by recording unipolar electrograms from an array of 1124 electrodes spaced 2 mm apart. The array had the shape of the ventricular surface of the heart. The electrograms were processed by a computer and displayed as epicardial equipotential maps at 1-msec intervals. Isochrone maps also were drawn. Several new features of epicardial potential fields were identified: (1) a high number of breakthrough points; (2) the topography, apparent widths, velocities of the wavefronts and the related potential drop; (3) the topography of positive potential peaks in relation to the wavefronts. Fifteen to 24 breakthrough points were located on the anterior, and 10 to 13 on the posterior ventricular surface. Some were in previously described locations and many others in new locations. Specifically, 3 to 5 breakthrough points appeared close to the atrioventricular groove on the anterior right ventricle and 2 to 4 on the posterior heart aspect; these basal breakthrough points appeared when a large portion of ventricular surface was still unexcited. Due to the presence of numerous breakthrough points on the anterior and posterior aspect of the heart which had not previously been described, the spread of excitation on the ventricular surface was "mosaic-like," with activation wavefronts spreading in all directions, rather than radially from the two breakthrough points, as traditionally described. The positive potential peaks which lay ahead of the expanding wavefronts moved along preferential directions which were probably related to the myocardial fiber direction.

  7. Blood pressure and heart rate variability analysis of orthostatic challenge in normal human pregnancies.

    Science.gov (United States)

    Heiskanen, Nonna; Saarelainen, Heli; Valtonen, Pirjo; Lyyra-Laitinen, Tiina; Laitinen, Tomi; Vanninen, Esko; Heinonen, Seppo

    2008-11-01

    The aim of the present study was to evaluate pregnancy-related changes in autonomic regulatory functions in healthy subjects. We studied cardiovascular autonomic responses to head-up tilt (HUT) in 28 pregnant women during the third trimester of pregnancy and 3 months after parturition. The maternal ECG and non-invasive beat-to-beat blood pressure were recorded in the horizontal position (left-lateral position) and during HUT in the upright position. Stroke volume was assessed from blood pressure signal by using the arterial pulse contour method. Heart rate variability (HRV) was analysed in frequency domain, and baroreflex sensitivity by the cross-spectral and the sequence methods. In the horizontal position, all frequency components of HRV were lower during pregnancy than 3 months after parturition (P pregnancy had no influence on normalized low frequency and high frequency powers. During pregnancy haemodynamics was well balanced with only minor changes in response to postural change while haemodynamic responses to HUT were more remarkable after parturition. In pregnant women HRV and especially its very low frequency component increased in response to HUT, whereas at 3 months after parturition the direction of these changes was opposite. Parasympathetic deactivation towards term is likely to contribute to increased heart rate and cardiac output at rest, whereas restored sympathetic modulation with modest responses may contribute stable peripheral resistance and sufficient placental blood supply under stimulated conditions. It is important to understand cardiovascular autonomic nervous system and haemodynamic control in normal pregnancy before being able to judge whether they are dysregulated in complicated pregnancies.

  8. Radiographic evaluations

    International Nuclear Information System (INIS)

    Williams, J.L.

    1988-01-01

    The author describes how to: perform a systematic evaluation of a chest radiograph; state the classic radiographic description of hyaline membrane disease; list the conditions that cause hyperaeration and describe the radiologic feature of hyperaeration; describe the radiograph of a patient with a congenital diaphragmatic hernia; identify optimum placement of an endotracheal tube, gastric feeding tube, and umbilical artery catheter on a radiograph; differentiate between pulmonary interstitial air and hyaline membrane disease; select radiographic features that would indicate the presence of a tension pneumothorax; describe a lateral decubitus projection and state the type of problem it is most often used to identify; explain the procedure used in obtaining a lateral neck radiograph and list two problems that may require this view; and describe the radiograph of a patient with cystic fibrosis

  9. Coronary heart disease patients transitioning to a normal life: perspectives and stages identified through a grounded theory approach.

    Science.gov (United States)

    Najafi Ghezeljeh, Tahereh; Yadavar Nikravesh, Mansoureh; Emami, Azita

    2014-02-01

    To explore how Iranian patients with coronary heart disease experience their lives. Coronary heart disease is a leading cause of death in Iran and worldwide. Understanding qualitatively how patients experience the acute and postacute stages of this chronic condition is essential knowledge for minimising the negative consequences of coronary heart disease. Qualitative study using grounded theory for the data analysis. Data for this study were collected through individual qualitative interviews with 24 patients with coronary heart disease, conducted between January 2009 and January 2011. Patients with angina pectoris were selected for participation through purposive sampling, and sample size was determined by data saturation. Data analysis began with initial coding and continued with focused coding. Categories were determined, and the core category was subsequently developed and finalised. The main categories of the transition from acute phase to a modified or 'new normal' life were: (1) Loss of normal life. Experiencing emotions and consequences of illness; (2) Coming to terms. Using coping strategies; (3) Recreating normal life. Healthcare providers must correctly recognise the stages of transition patients navigate while coping with coronary heart disease to support and educate them appropriately throughout these stages. Patients with coronary heart disease lose their normal lives and must work towards recreating a revised life using coping strategies that enable them to come to terms with their situations. By understanding Iranian patients' experiences, healthcare providers and especially nurses can use the information to support and educate patients with coronary heart disease on how to more effectively deal with their illness and its consequences. © 2013 John Wiley & Sons Ltd.

  10. Effect of Nebivolol on MIBG Parameters and Exercise in Heart Failure with Normal Ejection Fraction

    Energy Technology Data Exchange (ETDEWEB)

    Messias, Leandro Rocha, E-mail: lmessias@cardiol.br; Ferreira, Aryanne Guimarães; Miranda, Sandra Marina Ribeiro de; Teixeira, José Antônio Caldas [Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Azevedo, Jader Cunha de [Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Hospital Procardíaco, Rio de Janeiro, RJ (Brazil); Messias, Ana Carolina Nader Vasconcelos [Hospital Federal dos Servidores do Estado do Rio de Janeiro, Rio de Janeiro, RJ (Brazil); Maróstica, Elisabeth [Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Mesquita, Claudio Tinoco [Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Hospital Procardíaco, Rio de Janeiro, RJ (Brazil)

    2016-05-15

    More than 50% of the patients with heart failure have normal ejection fraction (HFNEF). Iodine-123 metaiodobenzylguanidine (123I-MIBG) scintigraphy and cardiopulmonary exercise test (CPET) are prognostic markers in HFNEF. Nebivolol is a beta-blocker with vasodilating properties. To evaluate the impact of nebivolol therapy on CPET and123I-MIBG scintigraphic parameters in patients with HFNEF. Twenty-five patients underwent 123I-MIBG scintigraphy to determine the washout rate and early and late heart-to-mediastinum ratios. During the CPET, we analyzed the systolic blood pressure (SBP) response, heart rate (HR) during effort and recovery (HRR), and oxygen uptake (VO{sub 2}). After the initial evaluation, we divided our cohort into control and intervention groups. We then started nebivolol and repeated the tests after 3 months. After treatment, the intervention group showed improvement in rest SBP (149 mmHg [143.5-171 mmHg] versus 135 mmHg [125-151 mmHg, p = 0.016]), rest HR (78 bpm [65.5-84 bpm] versus 64.5 bpm [57.5-75.5 bpm, p = 0.028]), peak SBP (235 mmHg [216.5-249 mmHg] versus 198 mmHg [191-220.5 mmHg], p = 0.001), peak HR (124.5 bpm [115-142 bpm] versus 115 bpm [103.7-124 bpm], p= 0.043), HRR on the 1st minute (6.5 bpm [4.75-12.75 bpm] versus 14.5 bpm [6.7-22 bpm], p = 0.025) and HRR on the 2nd minute (15.5 bpm [13-21.75 bpm] versus 23.5 bpm [16-31.7 bpm], p = 0.005), but no change in peak VO{sub 2} and 123I-MIBG scintigraphic parameters. Despite a better control in SBP, HR during rest and exercise, and improvement in HRR, nebivolol failed to show a positive effect on peak VO2 and 123I-MIBG scintigraphic parameters. The lack of effect on adrenergic activity may be the cause of the lack of effect on functional capacity.

  11. 31P MR spectroscopic measurement of intracellular pH in normal human hearts

    International Nuclear Information System (INIS)

    Kwon, Jae Hyun; Lee, Hui Joong; Jang, Yong Min

    2002-01-01

    To assess the usefulness of intracellular pH (pHi), calculated by determining the shift of a high-energy metabolite such as inorganic phosphate (Pi) of γ-ATP after performing MRS with ECG-gated two-dimensional 31 P CSI (chemical shift imaging), as a parameter for the overall state of the intracellular milieu. Proto decoupled 31 P CSI was performed on a 1.5-T scanner using a 1 H 31 P dual-tuned surface coil. Cardiac MRS data were obtained from eight normal volunteers aged 24-32 years with no history of heart disease. From the spectra obtained from several regions of the heart, peack position and peak area were estimated. The metabolic ratios of α-, β-, γ-ATP, PCr, Pi, phosphodiester and diphosphoglycerate were calculated, and pHi was estimated from the chemical shift of Pi and γ-ATP resonance. We then compared the data for the anterior myocardium with those previously published. The major phosphorous metabolites identified in these human hearts were as follows: PCr, at -0.1 to +0.1 ppm; three phosphate peaks from ATP, with a chemical shift centered at about -2.7 ppm (γ-ATP), -7.8 ppm (α-ATP), and -16.3 ppm (β-ATP); and phosphodiester (PDE) at 2-3 ppm, inorganic phosphate (Pi) at 4.5-5.4 ppm, and diphosphoglycerate (DPG) at 5.4-6.3 ppm. The PCr/β-ATP ratio was 2.20±0.17 and the PDE/β-ATP ratio, 1.04±0.09 pHi readings were 7.31±0.23 (calculated by the shift of Pi) and 6.81±0.20 (calculated by the shift of γ-ATP). Pi/PCR was 0.539, a ratio higher than that mentioned in previously published reports. The measurement of intracellular metabolism was affected by various kinds of factors. We believe, however, that pHi readings indicate the overall state of the cardiac intracellular milieu. An unexpected pHi readings, seen at MRS, may reflect errors in the MR procedure itself and, or in the analytical method

  12. {sup 31}P MR spectroscopic measurement of intracellular pH in normal human hearts

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Jae Hyun; Lee, Hui Joong; Jang, Yong Min [Kyungpook National Univ., Taegu (Korea, Republic of)] [and others

    2002-05-01

    To assess the usefulness of intracellular pH (pHi), calculated by determining the shift of a high-energy metabolite such as inorganic phosphate (Pi) of {gamma}-ATP after performing MRS with ECG-gated two-dimensional {sup 31}P CSI (chemical shift imaging), as a parameter for the overall state of the intracellular milieu. Proto decoupled {sup 31}P CSI was performed on a 1.5-T scanner using a {sup 1}H{sup 31}P dual-tuned surface coil. Cardiac MRS data were obtained from eight normal volunteers aged 24-32 years with no history of heart disease. From the spectra obtained from several regions of the heart, peack position and peak area were estimated. The metabolic ratios of {alpha}-, {beta}-, {gamma}-ATP, PCr, Pi, phosphodiester and diphosphoglycerate were calculated, and pHi was estimated from the chemical shift of Pi and {gamma}-ATP resonance. We then compared the data for the anterior myocardium with those previously published. The major phosphorous metabolites identified in these human hearts were as follows: PCr, at -0.1 to +0.1 ppm; three phosphate peaks from ATP, with a chemical shift centered at about -2.7 ppm ({gamma}-ATP), -7.8 ppm ({alpha}-ATP), and -16.3 ppm ({beta}-ATP); and phosphodiester (PDE) at 2-3 ppm, inorganic phosphate (Pi) at 4.5-5.4 ppm, and diphosphoglycerate (DPG) at 5.4-6.3 ppm. The PCr/{beta}-ATP ratio was 2.20{+-}0.17 and the PDE/{beta}-ATP ratio, 1.04{+-}0.09 pHi readings were 7.31{+-}0.23 (calculated by the shift of Pi) and 6.81{+-}0.20 (calculated by the shift of {gamma}-ATP). Pi/PCR was 0.539, a ratio higher than that mentioned in previously published reports. The measurement of intracellular metabolism was affected by various kinds of factors. We believe, however, that pHi readings indicate the overall state of the cardiac intracellular milieu. An unexpected pHi readings, seen at MRS, may reflect errors in the MR procedure itself and, or in the analytical method.

  13. Effect of Nebivolol on MIBG Parameters and Exercise in Heart Failure with Normal Ejection Fraction

    International Nuclear Information System (INIS)

    Messias, Leandro Rocha; Ferreira, Aryanne Guimarães; Miranda, Sandra Marina Ribeiro de; Teixeira, José Antônio Caldas; Azevedo, Jader Cunha de; Messias, Ana Carolina Nader Vasconcelos; Maróstica, Elisabeth; Mesquita, Claudio Tinoco

    2016-01-01

    More than 50% of the patients with heart failure have normal ejection fraction (HFNEF). Iodine-123 metaiodobenzylguanidine (123I-MIBG) scintigraphy and cardiopulmonary exercise test (CPET) are prognostic markers in HFNEF. Nebivolol is a beta-blocker with vasodilating properties. To evaluate the impact of nebivolol therapy on CPET and123I-MIBG scintigraphic parameters in patients with HFNEF. Twenty-five patients underwent 123I-MIBG scintigraphy to determine the washout rate and early and late heart-to-mediastinum ratios. During the CPET, we analyzed the systolic blood pressure (SBP) response, heart rate (HR) during effort and recovery (HRR), and oxygen uptake (VO 2 ). After the initial evaluation, we divided our cohort into control and intervention groups. We then started nebivolol and repeated the tests after 3 months. After treatment, the intervention group showed improvement in rest SBP (149 mmHg [143.5-171 mmHg] versus 135 mmHg [125-151 mmHg, p = 0.016]), rest HR (78 bpm [65.5-84 bpm] versus 64.5 bpm [57.5-75.5 bpm, p = 0.028]), peak SBP (235 mmHg [216.5-249 mmHg] versus 198 mmHg [191-220.5 mmHg], p = 0.001), peak HR (124.5 bpm [115-142 bpm] versus 115 bpm [103.7-124 bpm], p= 0.043), HRR on the 1st minute (6.5 bpm [4.75-12.75 bpm] versus 14.5 bpm [6.7-22 bpm], p = 0.025) and HRR on the 2nd minute (15.5 bpm [13-21.75 bpm] versus 23.5 bpm [16-31.7 bpm], p = 0.005), but no change in peak VO 2 and 123I-MIBG scintigraphic parameters. Despite a better control in SBP, HR during rest and exercise, and improvement in HRR, nebivolol failed to show a positive effect on peak VO2 and 123I-MIBG scintigraphic parameters. The lack of effect on adrenergic activity may be the cause of the lack of effect on functional capacity

  14. Pocket atlas of radiographic anatomy

    International Nuclear Information System (INIS)

    Moeller, T.B.; Reif, E.; Stark, P.

    1993-01-01

    The 'Pocket Atlas of Radiographic Anatomy' presents 170 radiographs of the various body regions of adults, showing only the normal radiographic anatomy. Each radiograph is supplemented on the opposite page by a drawing of the particular body region. There is no commenting text, but the drawings are provided with captions in English. The atlas is a useful guide for interpreting radiographs. The pictures are arranged in chapters entitled as follows: Skeletal Imaging (skull, spine, upper extremity), lower extremity; Miscellaneous Plain Films (chest, mammogram, trachea, lung tomograms); Contrast Examinations (gastrointestinal tract, intravenous contrast examinations, arthrography, angiography); Special Examinations (myelograms, lymphangiograms, bronchograms, sialograms). (UWA). 348 figs [de

  15. Timing of left heart base descent in dogs with dilated cardiomyopathy and normal dogs.

    Science.gov (United States)

    Simpson, Kerry E; Devine, Bryan C; Woolley, Richard; Corcoran, Brendan M; French, Anne T

    2008-01-01

    The identification and assessment of myocardial failure in canine idiopathic dilated cardiomyopathy (DCM) is achieved using a variety of two-dimensional and Doppler echocardiographic techniques. More recently, the availability of tissue Doppler imaging (TDI) has raised the potential for development of new ways of more accurately identifying a disease phenotype. Nevertheless, TDI has not been universally adapted to veterinary clinical cardiology primarily because of the lack of information on its utility in diagnosis. We assessed the application of timing of left heart base descent using TDI in the identification of differences between DCM and normal dogs. The times from the onset of the QRS complex on a simultaneously recorded electrocardiograph to the onset (Q--S'), peak (Q--peak S'), and end (Q--end S') of the systolic velocity peak were measured in the interventricular septum (IVS) and the left ventricular free wall. The duration of S' was also calculated. The Q--S' (FW), Q--end S' (FW), and duration S' (FW) were correlated with ejection fraction in the diseased group (P canine DCM and identifies new TDI parameters that can be added to the range of Doppler and echocardiographic parameters used for detecting myocardial failure in the dog.

  16. Normal Values for Heart Electrophysiology Parameters of Healthy Swine Determined on Electrophysiology Study.

    Science.gov (United States)

    Noszczyk-Nowak, Agnieszka; Cepiel, Alicja; Janiszewski, Adrian; Pasławski, Robert; Gajek, Jacek; Pasławska, Urszula; Nicpoń, Józef

    2016-01-01

    Swine are a well-recognized animal model for human cardiovascular diseases. Despite the widespread use of porcine model in experimental electrophysiology, still no reference values for intracardiac electrical activity and conduction parameters determined during an invasive electrophysiology study (EPS) have been developed in this species thus far. The aim of the study was to develop a set of normal values for intracardiac electrical activity and conduction parameters determined during an invasive EPS of swine. The study included 36 healthy domestic swine (24-40 kg body weight). EPS was performed under a general anesthesia with midazolam, propofol and isoflurane. The reference values for intracardiac electrical activity and conduction parameters were calculated as arithmetic means ± 2 standard deviations. The reference values were determined for AH, HV and PA intervals, interatrial conduction time at its own and imposed rhythm, sinus node recovery time (SNRT), corrected sinus node recovery time (CSNRT), anterograde and retrograde Wenckebach points, atrial, atrioventricular node and ventricular refractory periods. No significant correlations were found between body weight and heart rate of the examined pigs and their electrophysiological parameters. The hereby presented reference values can be helpful in comparing the results of various studies, as well as in more accurately estimating the values of electrophysiological parameters that can be expected in a given experiment.

  17. A human pericardium biopolymeric scaffold for autologous heart valve tissue engineering: cellular and extracellular matrix structure and biomechanical properties in comparison with a normal aortic heart valve.

    Science.gov (United States)

    Straka, Frantisek; Schornik, David; Masin, Jaroslav; Filova, Elena; Mirejovsky, Tomas; Burdikova, Zuzana; Svindrych, Zdenek; Chlup, Hynek; Horny, Lukas; Daniel, Matej; Machac, Jiri; Skibová, Jelena; Pirk, Jan; Bacakova, Lucie

    2018-04-01

    The objective of our study was to compare the cellular and extracellular matrix (ECM) structure and the biomechanical properties of human pericardium (HP) with the normal human aortic heart valve (NAV). HP tissues (from 12 patients) and NAV samples (from 5 patients) were harvested during heart surgery. The main cells in HP were pericardial interstitial cells, which are fibroblast-like cells of mesenchymal origin similar to the valvular interstitial cells in NAV tissue. The ECM of HP had a statistically significantly (p structures of the two tissues, the dense part of fibrous HP (49 ± 2%) and the lamina fibrosa of NAV (47 ± 4%), was similar. In both tissues, the secant elastic modulus (Es) was significantly lower in the transversal direction (p structure and has the biomechanical properties required for a tissue from which an autologous heart valve replacement may be constructed.

  18. Heart Failure Increases the Risk of Adverse Renal Outcomes in Patients With Normal Kidney Function.

    Science.gov (United States)

    George, Lekha K; Koshy, Santhosh K G; Molnar, Miklos Z; Thomas, Fridtjof; Lu, Jun L; Kalantar-Zadeh, Kamyar; Kovesdy, Csaba P

    2017-08-01

    Heart failure (HF) is associated with poor cardiac outcomes and mortality. It is not known whether HF leads to poor renal outcomes in patients with normal kidney function. We hypothesized that HF is associated with worse long-term renal outcomes. Among 3 570 865 US veterans with estimated glomerular filtration rate (eGFR) ≥60 mL min -1 1.73 m -2 during October 1, 2004 to September 30, 2006, we identified 156 743 with an International Classification of Diseases , Ninth Revision , diagnosis of HF. We examined the association of HF with incident chronic kidney disease (CKD), the composite of incident CKD or mortality, and rapid rate of eGFR decline (slopes steeper than -5 mL min -1 1.73 m -2 y -1 ) using Cox proportional hazard analyses and logistic regression. Adjustments were made for various confounders. The mean±standard deviation baseline age and eGFR of HF patients were 68±11 years and 78±14 mL min -1 1.73 m -2 and in patients without HF were 59±14 years and 84±16 mL min -1 1.73 m -2 , respectively. HF patients had higher prevalence of hypertension, diabetes mellitus, cardiac, peripheral vascular and chronic lung diseases, stroke, and dementia. Incidence of CKD was 69.0/1000 patient-years in HF patients versus 14.5/1000 patient-years in patients without HF, and 22% of patients with HF had rapid decline in eGFR compared with 8.5% in patients without HF. HF patients had a 2.12-, 2.06-, and 2.13-fold higher multivariable-adjusted risk of incident CKD, composite of CKD or mortality, and rapid eGFR decline, respectively. HF is associated with significantly higher risk of incident CKD, incident CKD or mortality, and rapid eGFR decline. Early diagnosis and management of HF could help reduce the risk of long-term renal complications. © 2017 American Heart Association, Inc.

  19. Radiographic testing

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wave-length radiation corresponding 10 to 25 kV.P. (orig.) [de

  20. In vitro cultured progenitors and precursors of cardiac cell lineages from human normal and post-ischemic hearts

    Directory of Open Access Journals (Sweden)

    F Di Meglio

    2009-08-01

    Full Text Available The demonstration of the presence of dividing primitive cells in damaged hearts has sparked increased interest about myocardium regenerative processes. We examined the rate and the differentiation of in vitro cultured resident cardiac primitive cells obtained from pathological and normal human hearts in order to evaluate the activation of progenitors and precursors of cardiac cell lineages in post-ischemic human hearts. The precursors and progenitors of cardiomyocyte, smooth muscle and endothelial lineage were identified by immunocytochemistry and the expression of characteristic markers was studied by western blot and RT-PCR. The amount of proteins characteristic for cardiac cells (a-SA and MHC, VEGFR-2 and FVIII, SMA for the precursors of cardiomyocytes, endothelial and smooth muscle cells, respectively inclines toward an increase in both a-SA and MHC. The increased levels of FVIII and VEGFR2 are statistically significant, suggesting an important re-activation of neoangiogenesis. At the same time, the augmented expression of mRNA for Nkx 2.5, the trascriptional factor for cardiomyocyte differentiation, confirms the persistence of differentiative processes in terminally injured hearts. Our study would appear to confirm the activation of human heart regeneration potential in pathological conditions and the ability of its primitive cells to maintain their proliferative capability in vitro. The cardiac cell isolation method we used could be useful in the future for studying modifications to the microenvironment that positively influence cardiac primitive cell differentiation or inhibit, or retard, the pathological remodeling and functional degradation of the heart.

  1. Patient experiences of recovery after heart valve replacement: suffering weakness, struggling to resume normality

    DEFF Research Database (Denmark)

    Kikkenborg Berg, Selina; Zwisler, Ann-Dorthe; Pedersen, Birthe D.

    2013-01-01

    Heart valve disease is becoming a public health problem due to increasing life expectancy and new treatment methods. Patients are at risk of developing depression, anxiety or post-traumatic stress disorder after heart valve surgery. To better plan proper care, describing and understanding patients...

  2. Global Bi-ventricular endocardial distribution of activation rate during long duration ventricular fibrillation in normal and heart failure canines.

    Science.gov (United States)

    Luo, Qingzhi; Jin, Qi; Zhang, Ning; Han, Yanxin; Wang, Yilong; Huang, Shangwei; Lin, Changjian; Ling, Tianyou; Chen, Kang; Pan, Wenqi; Wu, Liqun

    2017-04-13

    The objective of this study was to detect differences in the distribution of the left and right ventricle (LV & RV) activation rate (AR) during short-duration ventricular fibrillation (SDVF, 1 min) in normal and heart failure (HF) canine hearts. Ventricular fibrillation (VF) was electrically induced in six healthy dogs (control group) and six dogs with right ventricular pacing-induced congestive HF (HF group). Two 64-electrode basket catheters deployed in the LV and RV were used for global endocardium electrical mapping. The AR of VF was estimated by fast Fourier transform analysis from each electrode. In the control group, the LV was activated faster than the RV in the first 20 s, after which there was no detectable difference in the AR between them. When analyzing the distribution of the AR within the bi-ventricles at 3 min of LDVF, the posterior LV was activated fastest, while the anterior was slowest. In the HF group, a detectable AR gradient existed between the two ventricles within 3 min of VF, with the LV activating more quickly than the RV. When analyzing the distribution of the AR within the bi-ventricles at 3 min of LDVF, the septum of the LV was activated fastest, while the anterior was activated slowest. A global bi-ventricular endocardial AR gradient existed within the first 20 s of VF but disappeared in the LDVF in healthy hearts. However, the AR gradient was always observed in both SDVF and LDVF in HF hearts. The findings of this study suggest that LDVF in HF hearts can be maintained differently from normal hearts, which accordingly should lead to the development of different management strategies for LDVF resuscitation.

  3. Acromegaly with Normal Insulin-Like Growth Factor-1 Levels and Congestive Heart Failure as the First Clinical Manifestation

    Directory of Open Access Journals (Sweden)

    Hyae Min Lee

    2015-09-01

    Full Text Available The leading cause of morbidity and mortality in patients with acromegaly is cardiovascular complications. Myocardial exposure to excessive growth hormone can cause ventricular hypertrophy, hypertension, arrhythmia, and diastolic dysfunction. However, congestive heart failure as a result of systolic dysfunction is observed only rarely in patients with acromegaly. Most cases of acromegaly exhibit high levels of serum insulin-like growth factor-1 (IGF-1. Acromegaly with normal IGF-1 levels is rare and difficult to diagnose. Here, we report a rare case of an acromegalic patient whose first clinical manifestation was severe congestive heart failure, despite normal IGF-1 levels. We diagnosed acromegaly using a glucose-loading growth hormone suppression test. Cardiac function and myocardial hypertrophy improved 6 months after transsphenoidal resection of a pituitary adenoma.

  4. Radiographic positioning

    International Nuclear Information System (INIS)

    Eisenberg, R.L.; Dennis, C.A.; May, C.

    1989-01-01

    This book concentrates on the routine radiographic examinations commonly performed. It details the wide variety of examinations possible and their place in initial learning and in the radiology department as references for those occasions when an unusual examination is requested. This book provides information ranging from basic terminology to skeletal positioning to special procedures. Positions are discussed and supplemented with a picture of a patient, the resulting radiograph, and a labeled diagram. Immobilization and proper shielding of the patient are also shown

  5. Radiographic Test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H.J; Yang, S.H. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    This report contains theory, procedure technique and interpretation of radiographic examination and written for whom preparing radiographic test Level II. To determine this baseline of technical competence in the examination, the individual must demonstrate a knowledge of radiography physics, radiation safety, technique development, radiation detection and measurement, facility design, and the characteristics of radiation-producing devices and their principles of operation. (author) 98 figs., 23 tabs.

  6. Increased heart rate variability but normal resting metabolic rate in hypocretin/orexin-deficient human narcolepsy.

    NARCIS (Netherlands)

    Fronczek, R.; Overeem, S.; Reijntjes, R.; Lammers, G.J.; Dijk, J.G.M.; Pijl, H.

    2008-01-01

    STUDY OBJECTIVES: We investigated autonomic balance and resting metabolic rate to explore their possible involvement in obesity in hypocretin/orexin-deficient narcoleptic subjects. METHODS: Resting metabolic rate (using indirect calorimetry) and variability in heart rate and blood pressure were

  7. Hearts of dystonia musculorum mice display normal morphological and histological features but show signs of cardiac stress.

    Directory of Open Access Journals (Sweden)

    Justin G Boyer

    2010-03-01

    Full Text Available Dystonin is a giant cytoskeletal protein belonging to the plakin protein family and is believed to crosslink the major filament systems in contractile cells. Previous work has demonstrated skeletal muscle defects in dystonin-deficient dystonia musculorum (dt mice. In this study, we show that the dystonin muscle isoform is localized at the Z-disc, the H zone, the sarcolemma and intercalated discs in cardiac tissue. Based on this localization pattern, we tested whether dystonin-deficiency leads to structural defects in cardiac muscle. Desmin intermediate filament, microfilament, and microtubule subcellular organization appeared normal in dt hearts. Nevertheless, increased transcript levels of atrial natriuretic factor (ANF, 66% beta-myosin heavy chain (beta-MHC, 95% and decreased levels of sarcoplasmic reticulum calcium pump isoform 2A (SERCA2a, 26%, all signs of cardiac muscle stress, were noted in dt hearts. Hearts from two-week old dt mice were assessed for the presence of morphological and histological alterations. Heart to body weight ratios as well as left ventricular wall thickness and left chamber volume measurements were similar between dt and wild-type control mice. Hearts from dt mice also displayed no signs of fibrosis or calcification. Taken together, our data provide new insights into the intricate structure of the sarcomere by situating dystonin in cardiac muscle fibers and suggest that dystonin does not significantly influence the structural organization of cardiac muscle fibers during early postnatal development.

  8. Normal values of bone mineral density of the accessory carpus bone in Brasileiro de Hipismo (BH) horse breed using optical densitometry in radiographic image

    International Nuclear Information System (INIS)

    Godoy, C.L.B. de; Vulcano, L.C.; Santos, F.A.M.; Soares, J.C.M.

    2005-01-01

    Physiologic values of the bone mineral density (BMD) of the accessory carpal bone in Brasileiro de Hipismo (BH) horse breed were determined by radiographic optic densitometry (ROD), expressed in milimiters of alumminun (mmAl). Lateromedial radiographs of the carpus were taken from 12 intact males and 12 females, from 20 and up to 30 months of age. No significant difference was found in the average mineral bone density of the accessory carpal bone between males (4.7 ± 0.1mmAl) and females (4.,6 ± 0,1mmAl) from 20 to 30 months of age [pt

  9. Quantitative assessment of thallium myocardial washout rate: Importance of peak heart rate and lung thallium uptake in defining normal values

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Kozuka, Takahiro; Saito, Muneyasu; Sumiyoshi, Tetsuya; National Cardiovascular Center, Suita, Osaka

    1987-01-01

    Traditionally, the results of exercise thallium scintigraphy were interpreted by transient defect analysis using initial and delayed images. Recently, washout rate analysis has been used for the relative quantification of exercise thallium scintigraphy. A diffuse slow washout from all myocardial regions has been defined as the indicator of extensive coronary artery disease. However, slow washout has occasionally been observed in normal cases and in healthy myocardial segments which are not supplied by a stenosed artery in patients with single or double vessel disease. We evaluate the factors influencing washout rate in 100 normal patients and 63 patients with angina pectoris (33 cases of single vessel disease and 30 cases of double vessel disease). The washout rates were calculated using circumferential profile analysis. In normal patients, washout rate was closely related to peak heart rate (r=0.72) and inversely related to lung thallium uptake (r=-0.56). A diffuse slow washout was observed in seven (7%) of 100 normal patients, six (18%) of 33 cases of single vessel disease and eight (24%) of 30 cases of double vessel disease. The patients with diffuse slow washout showed significantly higher lung thallium uptake values and lower peak heart rates than those without diffuse slow washout (P<0.01). Thus, this false positive slow washout should be considered in the interpretation of quantitative exercise thallium scintigraphy. (orig.)

  10. Radiographic and computed tomographic evaluation of the canine intercondylar fossa in normal stifles and after notchplasty in stable and unstable stifles

    International Nuclear Information System (INIS)

    Fitch, R.B.; Hathcock, J.T.; Montgomery, R.D.

    1996-01-01

    The role of the intercondylar fossa in cranial cruciate ligament injury has gained notable attention in humans and it's role is now being questioned in animals. Controversy exists regarding the accuracy of radiographs and computed tomography (CT) in evaluating the intercondylar fossa. This study compared radiographic and CT evaluation with gross evaluation of the intercondylar fossa. Six greyhounds were evaluated before notchplasty, immediately after notchplasty and 6 months after notchplasty in stable and unstable stifles. A fossa width index was used for comparison because it negates the effects of patient size and radiographic magnification. The fossa width index is calculated by dividing the width of the intercondylar fossa by the total condylar width. The fossa width indices of dogs determined from radiographs and CT were not significantly different before notchplasty except for the cranial fossa width indices which were more inconsistent and tended to underestimate the size when compared to gross measurements. At six months, both stable and unstable stifles had refilling of the notchplasty, but the unstable stifles had significantly greater refilling resulting in no significant enlargement in intercondylar fossa size as compared to the prenotchplasty size. Osteophytes that occurred within the intercondylar fossa were less radiopaque and more easily visualized by computed tomography. Computed tomography provided several advantages, including clearer visualization of the intercondylar fossa, avoiding superimposition of the intercondylar fossa by caudal thigh muscles or tuber ischii and the ability to analyze the cranial and caudal components of the intercondylar fossa separately

  11. Physiological roles of the transient outward current Ito in normal and diseased hearts

    DEFF Research Database (Denmark)

    Cordeiro, Jonathan M.; Callø, Kirstine; Aschar-Sobbi, Roozbeh

    2016-01-01

    The Ca2+-independent transient outward K+ current (Ito) plays a critical role in underlying phase 1 of repolarization of the cardiac action potential and, as a result, is central to modulating excitation-contraction coupling and propensity for arrhythmia. Additionally, Ito and its molecular...... potential and the mechanisms by which Ito modulates excitation-contraction coupling. We also describe the effects of mutations in the subunits constituting the Ito channel as well as the role of Ito in the failing myocardium. Finally, we review pharmacological modulation of Ito and discuss the evidence...... constituents are consistently reduced in cardiac hypertrophy and heart failure. In this review, we discuss the physiological role of Ito as well as the molecular basis of this current in human and canine hearts, in which Ito has been thoroughly studied. In particular, we discuss the role of Ito in the action...

  12. Animal radiographs

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter presents historical x rays of a wide variety of animals taken within 5 years of the discovery of x radiation. Such photos were used as tests or as illustrations for radiographic publications. Numerous historical photographs are included. 10 refs

  13. Atrial and Ventricular Electrocardiographic Dromotropic Disturbances in Down Syndrome Patients with Structurally Normal Heart: A Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Yazdan Ghandi

    2018-03-01

    Full Text Available Background: We designed a cross-sectional study to determine electrocardiographic disorders in Down syndrome patients with congenitally normal hearts in a bid to predict fatal cardiac arrhythmia in the future. Materials and Methods: We investigated 60 children with DS without congenital abnormal hearts. Sixty healthy juveniles were also included in the study as a control group. Physical examination, electrocardiography, and echocardiography were performed in all subjects. Corrected QT interval (QTc was measured according to Bazett’s formula. Results: Patients with DS consisted of 32 males (53.33%, and 28 females (46.66%, aged 6–13 (9.21 ± 6.24 years old. Healthy subjects comprised 31 males (51.66%, and 29 females (48.33% with a mean age of 9.15 ± 5.01. The two groups were significantly different in terms of heart rate (P=0.006, maximum P-wave duration (P=0.001, and P-wave dispersion (PWd, P=0.0001. There was no statistically significant difference regarding minimum P-wave duration (P=0.176. The patients with DS had a greater maximum QTc interval, QT dispersion, and corrected QT interval dispersion (QTc-d than the healthy control subjects (P=0.001. However, there was no difference in maximum QT interval and minimum QTc interval between the two groups (P=0.67 and P=0.553, respectively. A positive correlation was found between age, heart rate, and all electrocardiographic variables. Conclusion: All DS patients, even in the absence of concomitant congenital heart disease should be followed up carefully by electrocardiography, looking for increased PWd and QTc-d to detect predisposed cases to arrhythmia.

  14. The normal heart - Part I. The cardiac outline and chamber anatomy

    International Nuclear Information System (INIS)

    Walker, J.

    1985-01-01

    The heart is the most open and the most secret object in all radiology. Surrounded by alveolar air (its natural contrast) its outline dominates the chest X-ray. The lung vessels, responding to any change in function, are openly displayed, but within the heart borders the X-ray shadow is obscure and its parts invisible; moreover its vital purpose, movement, is not seen. This hollow muscular organ is conical, its apex points downwards, forwards and to the left at 60 0 to the midline. It is roughly 12 cm in length and weighs about 350 g. The main vessels enter and leave at the base posteriorly. Its apex is free within the serous cavity of the pericardium but its base is fixed by vessels and by the pericardial reflexions which surround them. The embryonic dorsal mesopericardium between arteries and veins breaks down to give the transverse sinus which frees the heart posteriorly, and the reflexions around the pulmonary veins form a blind sac, the oblique sinus, which opens to the left. All is enclosed by fibrous pericardium and occupies the anterior mediastinum at the level of the 6th-9th dorsal vertebrae from which it is separated by the oesophagus, aorta and spinal muscles. It rests on the central tendon of the diaphragm and laterally the right and left lungs envelop it over more than two thirds of its surface

  15. Is "treat your child normally" helpful advice for parents of survivors of treatment of hypoplastic left heart syndrome?

    Science.gov (United States)

    Rempel, Gwen R; Harrison, Margaret J; Williamson, Deanna L

    2009-04-01

    Developing technology affords children with complex congenitally malformed hearts a chance for survival. Parents gratefully pursue life-saving options on behalf of their children, despite the risks to the life of their child, and uncertainty about outcomes. Little is known about how mothers and fathers experience parenting a child whose new state as a survivor may include less than optimal developmental sequels. Our study involved multiple interactive interviews with 9 mothers and 7 fathers of infants and preschool children with hypoplastic left heart syndrome who had survived the Norwood surgical approach. Qualitative methodology included grounded theory methods of simultaneous collection and analysis of data, and we used open and selective coding of transcribed interviews. Parents used normalization in the context of uncertainty regarding the ongoing survival of their child. Parents described their underweight children as being on their own growth curve, and viewed their developmental progress, however delayed, as reason for celebration, as they had been prepared for their child to die. There is growing evidence that children with congenitally malformed hearts who require surgical intervention during the first year of life may experience developmental delay. The use of normalization by their parents may be effective in decreasing their worry regarding the uncertain future faced by their child, but may negatively affect the developmental progress of the child if they do not seek resources to assist development. Advice from paediatric specialists for parents to view their children as normal needs to be balanced with assistance for parents to access services to support optimal growth and development of their child.

  16. Contribution of the Arterial System and the Heart to Blood Pressure during Normal Aging - A Simulation Study.

    Science.gov (United States)

    Maksuti, Elira; Westerhof, Nico; Westerhof, Berend E; Broomé, Michael; Stergiopulos, Nikos

    2016-01-01

    During aging, systolic blood pressure continuously increases over time, whereas diastolic pressure first increases and then slightly decreases after middle age. These pressure changes are usually explained by changes of the arterial system alone (increase in arterial stiffness and vascular resistance). However, we hypothesise that the heart contributes to the age-related blood pressure progression as well. In the present study we quantified the blood pressure changes in normal aging by using a Windkessel model for the arterial system and the time-varying elastance model for the heart, and compared the simulation results with data from the Framingham Heart Study. Parameters representing arterial changes (resistance and stiffness) during aging were based on literature values, whereas parameters representing cardiac changes were computed through physiological rules (compensated hypertrophy and preservation of end-diastolic volume). When taking into account arterial changes only, the systolic and diastolic pressure did not agree well with the population data. Between 20 and 80 years, systolic pressure increased from 100 to 122 mmHg, and diastolic pressure decreased from 76 to 55 mmHg. When taking cardiac adaptations into account as well, systolic and diastolic pressure increased from 100 to 151 mmHg and decreased from 76 to 69 mmHg, respectively. Our results show that not only the arterial system, but also the heart, contributes to the changes in blood pressure during aging. The changes in arterial properties initiate a systolic pressure increase, which in turn initiates a cardiac remodelling process that further augments systolic pressure and mitigates the decrease in diastolic pressure.

  17. Normal and abnormal electrical activation of the heart. Imaging patterns obtained by phase analysis of equilibrium cardiac studies

    International Nuclear Information System (INIS)

    Pavel, D.; Byrom, E.; Swiryn, S.; Meyer-Pavel, C.; Rosen, K.

    1981-01-01

    By using a temporal Fourier analysis of gated equilibrium cardiac studies, phase images were obtained. These functional images were analysed qualitatively and quantitatively to determine if specific patterns can be found for normal versus abnormal electrical activation of the heart. The study included eight subjects with normal cardiac function and 24 patients with abnormal electrical activation: eight with left bundle branch block (LBBB), two with right bundle branch block (RBBB), six with Wolff-Parkinson-White syndrome (WPW), one with junctional rhythm, one with spontaneous sustained ventricular tachycardia (VT) (all with normal wall motion), two with chronic transvenous pacemakers, and four with induced sustained VT (all with regional wall motion abnormalities). The results show that the two ventricals have the same mean phase (within +-9 0 ) in normals, but significantly different mean phases in all patients with bundle branch blocks. Of the six WPW patients, three had a distinctive abnormal pattern. The patient with junctional rhythm, those with transvenous pacemakers, and those with VT all had abnormal patterns on the phase image. The phase image is capable of showing differences between patients with electrical activation and a variety of electrical abnormalities. Within the latter category distinct patterns can be associated with each type of abnormality. (author)

  18. Thyroid Function Within the Normal Range and Risk of Coronary Heart Disease

    DEFF Research Database (Denmark)

    Åsvold, Bjørn O; Vatten, Lars J; Bjøro, Trine

    2015-01-01

    documented, but conflicting evidence suggests that thyrotropin levels in the upper part of the reference range may be associated with an increased risk of coronary heart disease (CHD). OBJECTIVE: To assess the association between differences in thyroid function within the reference range and CHD risk. DESIGN...... known thyroid or cardiovascular disease at baseline. EXPOSURES: Thyroid function as expressed by serum thyrotropin levels at baseline. MAIN OUTCOMES AND MEASURES: Hazard ratios (HRs) of CHD mortality and CHD events according to thyrotropin levels after adjustment for age, sex, and smoking status....... This finding suggests that differences in thyroid function within the population reference range do not influence the risk of CHD. Increased CHD risk does not appear to be a reason for lowering the upper thyrotropin reference limit....

  19. Radiographic evaluation of osteosynthesis

    International Nuclear Information System (INIS)

    Mueller-Miny, H.; Erlemann, R.; Roos, N.; Peters, P.E.; Baranowski, D.

    1991-01-01

    Surgeons, orthopedic surgeons, and neurosurgeons employ a wide variety of different osteosynthetic devices in the treatment of fractures and in spinal surgery. In order to assess these instruments correctly, the radiologist should be aware of their purpose and normal apperance. The complications should be identified, such as delayed union, pseudarthrosis, dislocation, device loosening, fracture of the device, osteomyelitis, and refracture. To evaluate the fixation device adequately two plain radiographs are mandatory. An normal fracture healing and the most commonly used fixation devices, the abnormalities of fracture healing and their complications are discussed. (orig.) [de

  20. Cardiopulmonary determinants of functional capacity in patients with chronic heart failure compared with normals.

    Science.gov (United States)

    Meyer, K; Westbrook, S; Schwaibold, M; Hajric, R; Lehmann, M; Roskamm, H

    1996-12-01

    Patients with chronic heart failure (CHF) are characterized by abnormal gas exchange and ventilatory responses to exercise. This study compares variables obtained from cardiopulmonary exercise testing in 35 patients with CHF with 35 age- and weight-matched healthy subjects. A second goal was to obtain cardiopulmonary variables measured at ventilatory threshold to distinguish patient changes from those of healthy subjects. Exercise testing was carried out using bicycle ergometry with ramplike protocol (work rate increments 12.5 W/min). Gas exchange and ventilation were measured breath by breath. Compared with healthy subjects, the VO2 in patients was lower at identical work rates (p rate, the variables for VO2, VCO2, ventilation, O2 pulse, ventilatory equivalents for O2 and CO2, and VD/VT (physiologic deadspace to tidal volume ratio), as well as lactate differed significantly at identical work rates. With the exception of VD/VT, all cardiopulmonary variables showed significant differences in their slopes during exercise. By means of a discriminant analysis, VCO2 and ventilation proved to be the most distinguishing variables at ventilatory threshold between patients with CHF and healthy subjects. These results indicate the clinical usefulness of cardiopulmonary exercise testing when assessing functional impairment due to CHF. For treatment evaluation, not only VO2 but also VCO2 and ventilation responses to exercise should be considered.

  1. The contribution of 3D quantitative meniscal and cartilage measures to variation in normal radiographic joint space width—Data from the Osteoarthritis Initiative healthy reference cohort

    International Nuclear Information System (INIS)

    Roth, Melanie; Wirth, Wolfgang; Emmanuel, Katja; Culvenor, Adam G.; Eckstein, Felix

    2017-01-01

    Objective: To explore to what extent three-dimensional measures of the meniscus and femorotibial cartilage explain the variation in medial and lateral femorotibial radiographic joint space width (JSW), in healthy men and women. Methods: The right knees of 87 Osteoarthritis Initiative healthy reference participants (no symptoms, radiographic signs or risk factors of osteoarthritis; 37 men, 50 women; age 55.0 ± 7.6; BMI 24.4 ± 3.1) were assessed. Quantitative measures of subregional femorotibial cartilage thickness and meniscal position and morphology were computed from segmented magnetic resonance images. Minimal and medial/lateral fixed-location JSW were determined from fixed-flexion radiographs. Correlation and regression analyses were used to explore the contribution of demographic, cartilage and meniscal parameters to JSW in healthy subjects. Results: The correlation with (medial) minimal JSW was somewhat stronger for cartilage thickness (0.54 ≤ r ≤ 0.67) than for meniscal (−0.31 ≤ r ≤ 0.50) or demographic measures (−0.15 ≤ r ≤ 0.48), in particular in men. In women, in contrast, the strength of the correlations of cartilage thickness and meniscal measures with minimal JSW were in the same range. Fixed-location JSW measures showed stronger correlations with cartilage thickness (r ≥ 0.68 medially; r ≥ 0.59 laterally) than with meniscal measures (r ≤ |0.32| medially; r ≤ |0.32| laterally). Stepwise regression models revealed that meniscal measures added significant independent information to the total variance explained in minimal JSW (adjusted multiple r 2 = 58%) but not in medial or lateral fixed-location JSW (r 2 = 60/51%, respectively). Conclusions: In healthy subjects, minimal JSW was observed to reflect a combination of cartilage and meniscal measures, particularly in women. Fixed-location JSW, in contrast, was found to be dominated by variance in cartilage thickness in both men and women, with somewhat higher correlations between

  2. The contribution of 3D quantitative meniscal and cartilage measures to variation in normal radiographic joint space width—Data from the Osteoarthritis Initiative healthy reference cohort

    Energy Technology Data Exchange (ETDEWEB)

    Roth, Melanie, E-mail: melanie.roth@pmu.ac.at [Institute of Anatomy, Paracelsus Medical University Salzburg & Nuremberg, Strubergasse 21, 5020, Salzburg (Austria); Wirth, Wolfgang, E-mail: wolfgang.wirth@pmu.ac.at [Institute of Anatomy, Paracelsus Medical University Salzburg & Nuremberg, Strubergasse 21, 5020, Salzburg (Austria); Chondrometrics GmbH, Ulrichshöglerstrasse 23, 83404, Ainring (Germany); Emmanuel, Katja, E-mail: katja.emmanuel@icloud.com [Institute of Anatomy, Paracelsus Medical University Salzburg & Nuremberg, Strubergasse 21, 5020, Salzburg (Austria); Department of Orthopedics and Traumatology, Paracelsus Medical University, Müllner Hauptstraße 48, 5020, Salzburg (Austria); Culvenor, Adam G., E-mail: adam.culvenor@pmu.ac.at [Institute of Anatomy, Paracelsus Medical University Salzburg & Nuremberg, Strubergasse 21, 5020, Salzburg (Austria); School of Allied Health, La Trobe University, Plenty Road, Bundoora, 3086, Victoria (Australia); Eckstein, Felix, E-mail: felix.eckstein@pmu.ac.at [Institute of Anatomy, Paracelsus Medical University Salzburg & Nuremberg, Strubergasse 21, 5020, Salzburg (Austria); Chondrometrics GmbH, Ulrichshöglerstrasse 23, 83404, Ainring (Germany)

    2017-02-15

    Objective: To explore to what extent three-dimensional measures of the meniscus and femorotibial cartilage explain the variation in medial and lateral femorotibial radiographic joint space width (JSW), in healthy men and women. Methods: The right knees of 87 Osteoarthritis Initiative healthy reference participants (no symptoms, radiographic signs or risk factors of osteoarthritis; 37 men, 50 women; age 55.0 ± 7.6; BMI 24.4 ± 3.1) were assessed. Quantitative measures of subregional femorotibial cartilage thickness and meniscal position and morphology were computed from segmented magnetic resonance images. Minimal and medial/lateral fixed-location JSW were determined from fixed-flexion radiographs. Correlation and regression analyses were used to explore the contribution of demographic, cartilage and meniscal parameters to JSW in healthy subjects. Results: The correlation with (medial) minimal JSW was somewhat stronger for cartilage thickness (0.54 ≤ r ≤ 0.67) than for meniscal (−0.31 ≤ r ≤ 0.50) or demographic measures (−0.15 ≤ r ≤ 0.48), in particular in men. In women, in contrast, the strength of the correlations of cartilage thickness and meniscal measures with minimal JSW were in the same range. Fixed-location JSW measures showed stronger correlations with cartilage thickness (r ≥ 0.68 medially; r ≥ 0.59 laterally) than with meniscal measures (r ≤ |0.32| medially; r ≤ |0.32| laterally). Stepwise regression models revealed that meniscal measures added significant independent information to the total variance explained in minimal JSW (adjusted multiple r{sup 2} = 58%) but not in medial or lateral fixed-location JSW (r{sup 2} = 60/51%, respectively). Conclusions: In healthy subjects, minimal JSW was observed to reflect a combination of cartilage and meniscal measures, particularly in women. Fixed-location JSW, in contrast, was found to be dominated by variance in cartilage thickness in both men and women, with somewhat higher correlations

  3. Radiographic element

    International Nuclear Information System (INIS)

    Abbott, T.I.; Jones, C.G.

    1984-01-01

    Radiographic elements are disclosed comprised of first and second silver halide emulsion layers separated by an interposed support capable of transmitting radiation to which the second image portion is responsive. At least the first imaging portion contains a silver halide emulsion in which thin tubular silver halide grains of intermediate aspect ratios (from 5:1 to 8:1) are present. Spectral sensitizing dye is adsorbed to the surface of the tubular grains. Increased photographic speeds can be realized at comparable levels of crossover. (author)

  4. Frequency and topography of lesions of the femoro-tibial cartilage at spiral CT arthrography of the knee: a study in patients with normal knee radiographs and without history of trauma

    International Nuclear Information System (INIS)

    Vande Berg, B.C.; Lecouvet, F.E.; Malghem, J.

    2002-01-01

    To determine the frequency and topography of cartilage lesions involving the femoro-tibial joints in patients with normal knee radiographs and without a remembered history of trauma.Design and patients. A radiologist retrospectively reviewed the dual-detector spiral CT knee arthrograms performed in 209 consecutive patients (mean age 37.6 years) with normal knee radiographs. Images were analyzed for the presence, grade (Noyes classification system) and location of cartilage lesions, the location being designated by dividing each articular surface into a grid of 16 parts.Results. Fifty-three percent of knees had cartilage lesions of grade 2A or higher that involved articular surfaces to a variable extent: lateral tibial plateau (31%), medial femoral condyle (27%), medial tibial plateau (14%) and lateral femoral condyle (5%). Areas of the posterior half of the lateral tibial plateau and of the inner half of the medial femoral condyle were statistically more frequently involved than their counterparts (P<0.0001). The bare area of the medial tibial plateau, but not that of the lateral tibial plateau, was more frequently involved than the corresponding meniscus-covered area (P<0.0001).Conclusion. Cartilage lesions of grade 2A or higher, detected at spiral CT arthrography in 53% of the knees, predominantly involved the posterior half of the lateral tibial plateau, the inner half of the medial femoral condyle and the bare area of the medial tibial plateau. (orig.)

  5. Classification of caesarean section and normal vaginal deliveries using foetal heart rate signals and advanced machine learning algorithms.

    Science.gov (United States)

    Fergus, Paul; Hussain, Abir; Al-Jumeily, Dhiya; Huang, De-Shuang; Bouguila, Nizar

    2017-07-06

    Visual inspection of cardiotocography traces by obstetricians and midwives is the gold standard for monitoring the wellbeing of the foetus during antenatal care. However, inter- and intra-observer variability is high with only a 30% positive predictive value for the classification of pathological outcomes. This has a significant negative impact on the perinatal foetus and often results in cardio-pulmonary arrest, brain and vital organ damage, cerebral palsy, hearing, visual and cognitive defects and in severe cases, death. This paper shows that using machine learning and foetal heart rate signals provides direct information about the foetal state and helps to filter the subjective opinions of medical practitioners when used as a decision support tool. The primary aim is to provide a proof-of-concept that demonstrates how machine learning can be used to objectively determine when medical intervention, such as caesarean section, is required and help avoid preventable perinatal deaths. This is evidenced using an open dataset that comprises 506 controls (normal virginal deliveries) and 46 cases (caesarean due to pH ≤ 7.20-acidosis, n = 18; pH > 7.20 and pH machine-learning algorithms are trained, and validated, using binary classifier performance measures. The findings show that deep learning classification achieves sensitivity = 94%, specificity = 91%, Area under the curve = 99%, F-score = 100%, and mean square error = 1%. The results demonstrate that machine learning significantly improves the efficiency for the detection of caesarean section and normal vaginal deliveries using foetal heart rate signals compared with obstetrician and midwife predictions and systems reported in previous studies.

  6. Radiographically detectable intracortical porosity

    International Nuclear Information System (INIS)

    Meema, H.E.

    1986-01-01

    Since the measurement of intracortical resorptive spaces by histologic methods is difficult and very few data are available in normal humans, we have measured their lengths and widths and calculated the intracortical porosity in metacarpals and phalanges of 79 normal women and 69 normal men, using fine-detail radiographs of the hands and a computerized semi-automatic image analysis system (Zeiss MOP-3), this being the first study of this kind. Several methodological problems were solved satisfactorily, and the results of this study could serve as a data bank for further investigations concerned with intracortical resorption. Significant differences were found between age and sex versus several intracortical resorptive parameters; also significant correlations were found with age in some cases. Normal intracortical porosity was found to be about three times greater in the proximal phalanges than in the metacarpals. It is concluded that this methodology could be used for further studies of intracortical resorption in osteoporosis and other metabolic bone diseases. (orig.)

  7. Detection and prognostic impact of renal dysfunction in patients with chronic heart failure and normal serum creatinine.

    Science.gov (United States)

    Scrutinio, Domenico; Passantino, Andrea; Lagioia, Rocco; Santoro, Daniela; Cacciapaglia, Erasmo

    2011-03-03

    Accurate identification of renal dysfunction (RD) is crucial to risk stratification in chronic heart failure (CHF). Patients with CHF are at special risk of having RD despite normal serum creatinine (SCr), owing to a decreased Cr generation. At low levels of SCr, the equations estimating renal function are less accurate. This study was aimed to assess and compare the prognostic value of formulas estimating renal function in CHF patients with normal SCr. We studied 462 patients with systolic CHF and normal SCr. Creatinine clearance was estimated by the Cockcroft-Gault (eCrCl) and glomerular filtration rate by the 4-variable MDRD equation (eGFR); eCrCl normalized for body-surface area (eCrCl(BSA)) was calculated. The primary outcome was all-cause mortality at 2 years. Seventy five patients died. At multivariate Cox regression analysis, only eCrCl(BSA) was significantly associated with mortality (p = 0.006); eGFR (p = 0.24), eCrCl (p = 0.09) and BUN (p = 0.14) were not statistically significant predictors. The patients in the lowest eCrCl(BSA) quartile had an adjusted 2.1-fold (CI: 1.06-4.1) increased risk of mortality, compared with those in the referent quartile. Two-year survival was 70.4% in the lowest eCrCl(BSA) quartile and 89.7% in the referent quartile. Other independent predictors of mortality were ischemic etiology (RR: 2.16 [CI: 1.3-3.5], p = 0.0017), NYHA III/IV class (RR: 2.45 [CI: 1.51-3.97], p = 0.0003), LVEF high-risk subgroup and can more accurately be identified by the CG formula corrected for BSA than the MDRD. Copyright © 2009 Elsevier B.V. All rights reserved.

  8. Normal values for myocardial deformation within the right heart measured by feature-tracking cardiovascular magnetic resonance imaging.

    Science.gov (United States)

    Liu, Boyang; Dardeer, Ahmed M; Moody, William E; Edwards, Nicola C; Hudsmith, Lucy E; Steeds, Richard P

    2018-02-01

    Reproducible and repeatable assessment of right heart function is vital for monitoring congenital and acquired heart disease. There is increasing evidence for the additional value of myocardial deformation (strain and strain rate) in determining prognosis. This study aims to determine the reproducibility of deformation analyses in the right heart using cardiovascular magnetic resonance feature tracking (FT-CMR); and to establish normal ranges within an adult population. A cohort of 100 healthy subjects containing 10 males and 10 females from each decade of life between the ages of 20 and 70 without known congenital or acquired cardiovascular disease, hypertension, diabetes, dyslipidaemia or renal, hepatic, haematologic and systemic inflammatory disorders underwent FT-CMR assessment of right ventricular (RV) and right atrial (RA) myocardial strain and strain rate. RV longitudinal strain (Ell) was -21.9±3.24% (FW+S Ell) and -24.2±3.59% (FW-Ell). Peak systolic strain rate (S') was -1.45±0.39s -1 (FW+S) and -1.54±0.41s -1 (FW). Early diastolic strain rate (E') was 1.04±0.26s -1 (FW+S) and 1.04±0.33s -1 (FW). Late diastolic strain rate (A') was 0.94±0.33s -1 (FW+S) and 1.08±0.33s -1 (FW). RA peak strain was -21.1±3.76%. The intra- and inter-observer ICC for RV Ell (FW+S) was 0.92 and 0.80 respectively, while for RA peak strain was 0.92 and 0.89 respectively. Normal values of RV & RA deformation for healthy individuals using FT-CMR are provided with good RV Ell and RA peak strain reproducibility. Strain rate suffered from sub-optimal reproducibility and may not be satisfactory for clinical use. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Radiographic apparatus

    International Nuclear Information System (INIS)

    Lapidus, S.N.

    1979-01-01

    Raytheon Company, U.S.A. have patented an on-line electronic system of normalising the responses from the photomultiplier tubes used in conjunction with a scintillator in an X-ray radiographic camera. A problem with present cameras is that the individual photomultipliers have different intensity responses which also change in time with respect to each other. The individual responses of each photomultiplier tube are measured with a uniform sheet of radioactive material in front of the camera. The associated electronic equipment then calculates scaling factors which give all photomultiplier tubes an identical response and then places these factors in an addressable store. The store is then addressed in an on-line mode to produce a visual display of the transmitted X-rays. (U.K.)

  10. Radiographic apparatus

    International Nuclear Information System (INIS)

    Dalton, B.L.

    1984-01-01

    This patent application describes a radiographic apparatus including an array of radiation sensors, a source of radiation for projecting a beam through a body and means for moving one of said source and array relative to the body and for producing an electrical signal representative of the movement of the other of said source and array needed to bring the array into register with the beam. Drive means are arranged to move the other of said source and array in response to the electrical signal. In one embodiment, the source is rotated by an amount measured by a grating and associated electronics. The required movement of the array to maintain registration is calculated and transmitted to a driver. Alternatively, a laser may be mounted with the same and the array driven so that the laser beam continuously impinges on a photocell mounted with the array. (author)

  11. Clinical Characteristics and Findings of 99mTc-MIBI Heart SPECT in Patients with Acute Myocardial Infarction with Normal Coronary Arteriography

    International Nuclear Information System (INIS)

    Park, Myung Jae; Choi, Tae Youl; Kim, Deong Yoon; Kang, Heung Sun; Choue, Chung Whee; Kim, Kwon Sam; Kim, Kwang Won; Kim, Myung Shick; Song, Jung Sang; Bae, Jong Hoa

    1993-01-01

    Among 64 patients with acute myocardial infarction who underwent coronary angiography, 7 patients (10.9%)showed normal coronary artery. Six patients were men and 1 patient was female. The mean age of patients were 31.1 ± 3.9 years. Among the risk factors of coronary heart disease, smoking was most probable factor in patients with acute myocardial infarction with normal coronary angiography. 99m Tc-MIBI heart SPECT performed 5 of 7 patients and showed that it could be used in diagnosis, localization, extent of infarct area in patients with acute myocardial infarction with normal coronary angiography. But follow up 99m Tc-MIBI heart SPECT study will be needed to define the ability of myocardial viability in this patients.

  12. Heart rate variability and QT dispersion study in brain death patients and comatose patients with normal brainstem function

    International Nuclear Information System (INIS)

    Vakilian, A.R.; Iranmanesh, F.; Nadimi, A.E.; Kahnali, J.A.

    2011-01-01

    To compare heart rate variability (HRV) and QT dispersion in comatose patients with normal brainstem function and with brain death. Fourteen brain death patients with clinical signs of imminent brain death and 15 comatose patients were examined by neurologist in intensive care unit. HRV, RR interval and QT dispersion on ECG were assessed for 24 hours in both groups. Independent t-test and chi-square test were used for statistical analysis to determine significance which was set at p < 0.05. According to Holter findings, mean of standard deviation of RR-interval in the comatose and brain death groups was 48.33 and 35 respectively (p = 0.045). Mean of covariance coefficient of RR-interval was 0.065 in the comatose group and 0.043 in the brain deaths (p = 0.006). QT dispersion was not significant difference in two groups. HRV and RR-interval analysis appeared as an early finding for the diagnosis of brainstem death in comparison to comatose patients with normal brainstem function. QT dispersion had not significant in this regard. (author)

  13. Radiographers and trainee radiologists reporting accident radiographs

    DEFF Research Database (Denmark)

    Buskov, L; Abild, A; Christensen, A

    2013-01-01

    To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital....

  14. Assessment of myocardial washout of Tc-99m-sestamibi in patients with chronic heart failure. Comparison with normal control

    Energy Technology Data Exchange (ETDEWEB)

    Kumita, Shin-ichiro; Seino, Yoshihiko; Cho, Keiichi; Nakajo, Hidenobu; Toba, Masahiro; Fukushima, Yoshimitsu; Takano, Teruo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan); Okamoto, Noriake [Bristol-Myers Squibb K.K., Tokyo (Japan)

    2002-06-01

    In contrast to {sup 201}TlCl, {sup 99m}Tc-sestamibi shows very slow myocardial clearance after its initial myocardial uptake. In the present study, myocardial washout of {sup 99m}Tc-sestamibi was calculated in patients with non-ischemic chronic heart failure (CHF) and compared with biventricular parameters obtained from first-pass and ECG-gated myocardial perfusion SPECT data. After administration of {sup 99m}Tc-sestamibi, 25 patients with CHF and 8 normal controls (NC) were examined by ECG-gated myocardial perfusion SPECT and planar data acquisition in the early and delayed (interval of 3 hours) phase. Left ventricular ejection fraction (LVEF, %), peak filling rate (PFR, sec{sup -1}), end-diastolic volume (LVEDV, ml) and end-systolic volume (LVESV, ml) were automatically calculated from the ECG-gated SPECT data. Myocardial washout rates over 3 hours were calculated from the early and delayed planar images. Myocardial washout rates in the CHF group (39.6{+-}5.2%) were significantly higher than those in the NC group (31.2{+-}5.5%, p<0.01). The myocardial washout rates for the 33 subjects showed significant correlations with LVEF (r=-0.61, p<0.001), PFR (r=-0.47, p<0.01), LVEDV (r=0.45, p<0.01) and LVESV (r=0.48, p<0.01). The myocardial washout rate of {sup 99m}Tc-sestamibi is considered to be a novel marker for the diagnosis of myocardial damage in patients with chronic heart failure. (author)

  15. Radiographic findings of primary lung cancer with delayed detection on chest radiographs

    International Nuclear Information System (INIS)

    Kim, Young Min; Kim, Jin Hwan; Jung, Bin Young; Jun, Kwang Jin; Jeong, Ki Ho; Kim, Ju Ok; Kim, Sun Young; Yang, Chang Kyu

    1999-01-01

    To analyze the causes of delayed detection of lung cancer on chest radiographs. We retrospectively reviewed 105 cases in which an initial diagnosis of lung cancer, based on an examination of plain radiographs, had been missed or misinterpreted. All occurred between October 1993 and April 1997. We reviewed the initial chest radiographs and compared the features noted with those seen on later chest radiographs and computed tomographic (CT) images. Undetected lung cancer was identified in 56 patients (56/105, 53.3%) It had been hidden by superimposed structures (41, 73.2%), overlapped by combined benign diseases (12, 21.4%), or the nodules were subtle (3, 5.4%). Of the 41 lung cancers hidden by a superimposed structure, the central type accounted for 29 (70.7%) and the peripheral type for 12 (29.3%). The 29 central type had been hidden by the left hilum (n=15), the right hilum (n=10), the heart (n=3), or a rib (n=1). The twelve peripheral type were hidden by a rib (n=7), the heart (n=2), the diaphragm (n=2), or the left hilum (n=1). Of the 12 lung cancers overlapped by combined benign diseases, pulmonary tuberculosis (n=6), pleural effusion (n=4), congestive heart failure (n=1), and diffuse interstitial lung disease (n=1) were present at the time of interpretation. The misinterpreted lung cancers were identified in 49 patients (49/105, 46.7%) and were seen to be combined with benign disease (16, 32.6%), or as obstructive pneumonia without a central mass (15, 30.6%), air-space consolidation (7, 14.3%), cavity (7, 14.3%), double lesion (2, 4.1%), or young age below 26 years (2,4.1%). Of the 16 lung cancers misinterpreted as combined disease, pulmonary tuberculosis (n=14) and pleural disease (n=2) had been initially diagnosed. Most commonly, lung cancer was missed or misinterpreted because it was hidden by a normal structure or combined with a benign disease. Perceptual errors can be reduced by appropriate techniques and the scrutiny of trouble spots such as the

  16. Radiographic tales

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder

    Purpose Until now a large number of scientific studies have focused on technological aspects of radiography. This study is a step in another direction which examines the relationship between man and technology within radiography instead of considering man and technology as separate entities. Meth...... of their narrative alertness. Errors and failure to keep the time schedule can, however, lead the radiographers to a change of perspective that makes them displace man from the scene of radiography by playing on the premises of technology.......Purpose Until now a large number of scientific studies have focused on technological aspects of radiography. This study is a step in another direction which examines the relationship between man and technology within radiography instead of considering man and technology as separate entities...... a practice in which the relationship between man and technology is marked by a struggle of domination of one over the other. The struggle expresses itself through two competing plots: A diagnostic plot with a prevailing, but not merely chronological structure mostly composed of events tied to pathology...

  17. Comparison of the image quality of digital radiography system and film screen system - Radiologist' rating of the visibility of normal anatomic - Structures in chest PA, Skull radiograph and K. U. B

    International Nuclear Information System (INIS)

    Song, Kounn Sik; Kim, Young Goo; Lee, Jong Beum; Kim, Kun Sang

    1987-01-01

    Digital image acquisition and display is widely used in computed tomography, ultrasonography, digital subtraction angiography, nuclear medicine and magnetic resonance image. But most of the radiological examinations performed in radiology department are made by using conventional system. The development of the digital radiography system is essential if totally digitized radiology department is desired. The advantages of digitizing the radiographic information are usually discussed in terms of PACS (picture archiving and communication system), furthermore there are many other advantages such as contrast modification, spatial filtering subtraction and superimposition of the images through the image processing by computer. Currently several approaches are under development or in clinical use, the most promising approach is the use of imaging plate composed of photostimulate phosphors such as barium fluorohalide crystal read with a He-Ne laser to produce digital radiographic images. Another promising approach is scan projection radiography. The authors performed the clinical study of comparing the image qualities of digital radiography system using scanning laser luminescence (FCR) and conventional film-screen system in chest PA, skull radiography and K. U. B. in terms of the visibility of the normal anatomic structure rating those (qualities) on a scale of 0 to 3 and obtained the following results. Normal contrast digital images are comparable to conventional film-screen images, but the images of high frequency enhancement is far superior to conventional film-screen especially in peripherally located structures such as skin, subcutaneous fat, musculoskeletal systems, nasal bone, inner and outer table of the skull including the diploic space, paranasal sinuses, nasopharynx and larynx, trachea and main bronchi, mediastinal structures, retrocardiac and subphrenic vascular markings. Another promising aspects of digital radiography system is its wide exposure latitude and

  18. Significance of calcific valvular heart disease in /sup 99m/Tc pyrophosphate myocardial infarction scanning: radiographic, scintigraphic, and pathological correlation

    International Nuclear Information System (INIS)

    Jengo, J.A.; Mena, I.; Joe, S.H.; Criley, J.M.

    1977-01-01

    Technetium-99m pyrophosphate (PP/sub i/) is currently considered the best scanning agent for the diagnosis of acute myocardial infarction. False-positive scans have been reported in association with unstable angina, alcoholic cardiomyopathy, and ventricular aneurysms. In this study, 86 percent of patients (12/14) with either calcific aortic or mitral valvular heart disease had positive PP/sub i/ cardiac scintiscans and the location of the PP/sub i/ uptake was limited to the calcific valve in all (9/9) of the patients who underwent valve replacement surgery. Six patients with valvular disease without radiologic evidence of calcium had negative PP/sub i/ heart images. Three of these patients had surgical valve replacement, and in none was there increased uptake in the resected valve. Seventy-five percent of the patients with calcified aortic valves had localization of the PP/sub i/ activity to the area of the aortic valve, whereas 50 percent of the patients with calcified mitral valves showed a diffuse pattern of uptake on the cardiac image. In vitro demonstration of increased radioactivity in surgically removed cardiac valves warrants the conclusion that Tc-99m PP/sub i/ is taken up by calcified heart valves. We conclude that while PP/sub i/ heart scanning is a sensitive indicator of acute myocardial infarction, false-positive scans can occur in the presence of calcific valvular disease, due to localization of PP/sub i/ in the calcified portion of the valve

  19. Significance of calcific valvular heart disease in /sup 99m/Tc pyrophosphate myocardial infarction scanning: radiographic, scintigraphic, and pathological correlation

    Energy Technology Data Exchange (ETDEWEB)

    Jengo, J.A.; Mena, I.; Joe, S.H.; Criley, J.M.

    1977-08-01

    Technetium-99m pyrophosphate (PP/sub i/) is currently considered the best scanning agent for the diagnosis of acute myocardial infarction. False-positive scans have been reported in association with unstable angina, alcoholic cardiomyopathy, and ventricular aneurysms. In this study, 86 percent of patients (12/14) with either calcific aortic or mitral valvular heart disease had positive PP/sub i/ cardiac scintiscans and the location of the PP/sub i/ uptake was limited to the calcific valve in all (9/9) of the patients who underwent valve replacement surgery. Six patients with valvular disease without radiologic evidence of calcium had negative PP/sub i/ heart images. Three of these patients had surgical valve replacement, and in none was there increased uptake in the resected valve. Seventy-five percent of the patients with calcified aortic valves had localization of the PP/sub i/ activity to the area of the aortic valve, whereas 50 percent of the patients with calcified mitral valves showed a diffuse pattern of uptake on the cardiac image. In vitro demonstration of increased radioactivity in surgically removed cardiac valves warrants the conclusion that Tc-99m PP/sub i/ is taken up by calcified heart valves. We conclude that while PP/sub i/ heart scanning is a sensitive indicator of acute myocardial infarction, false-positive scans can occur in the presence of calcific valvular disease, due to localization of PP/sub i/ in the calcified portion of the valve.

  20. Radiographic arthrosis after elbow trauma: interobserver reliability.

    NARCIS (Netherlands)

    Lindenhovius, A.; Karanicolas, P.J.; Bhandari, M.; Ring, D.; Kampen, A. van; et al.,

    2012-01-01

    PURPOSE: This study measured observer variation in radiographic rating of elbow arthrosis. METHODS: Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  1. Radiographic Arthrosis After Elbow Trauma: Interobserver Reliability

    NARCIS (Netherlands)

    Lindenhovius, Anneluuk; Karanicolas, Paul Jack; Bhandari, Mohit; Ring, David; Allan, Cristopher; Axelrod, Terry; Baratz, Mark; Beingessner, Daphne; Cassidy, Charles; Coles, Chad; Conflitti, Joe; Rocca, Gregory Della; van Dijk, C. Niek; Elmans, L. H. G. J.; Feibe, Roger; Frihagen, Frede; Gosens, Taco; Greenberg, Jeffrey; Grosso, Elena; Harness, Neil; van der Heide, Huub; Jeray, Kyle; Kalainov, David; van Kampen, Albert; Kawamura, Sumito; Kloen, Peter; McCormac, Bob; McKee, Michael; Page, Richard; Pesantez, Rodrigo; Peters, Anil; Petrisor, Brad; Poolman, Rudolf; Richardson, Martin; Seiler, John; Swiontkowski, Marc; Trumble, Thomas; Wright, Thomas; Zalavras, Charalampos; Zura, Robert

    2012-01-01

    Purpose This study measured observer variation in radiographic rating of elbow arthrosis. Methods Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  2. Cloning, chromosomal localization, and functional expression of the alpha 1 subunit of the L-type voltage-dependent calcium channel from normal human heart

    NARCIS (Netherlands)

    Schultz, D; Mikala, G; Yatani, A; Engle, D B; Iles, D E; Segers, B; Sinke, R J; Weghuis, D O; Klöckner, U; Wakamori, M

    1993-01-01

    A unique structural variant of the cardiac L-type voltage-dependent calcium channel alpha 1 subunit cDNA was isolated from libraries derived from normal human heart mRNA. The deduced amino acid sequence shows significant homology to other calcium channel alpha 1 subunits. However, differences from

  3. Correcting human heart 31P NMR spectra for partial saturation. Evidence that saturation factors for PCr/ATP are homogeneous in normal and disease states

    Science.gov (United States)

    Bottomley, Paul A.; Hardy, Christopher J.; Weiss, Robert G.

    Heart PCr/ATP ratios measured from spatially localized 31P NMR spectra can be corrected for partial saturation effects using saturation factors derived from unlocalized chest surface-coil spectra acquired at the heart rate and approximate Ernst angle for phosphor creatine (PCr) and again under fully relaxed conditions during each 31P exam. To validate this approach in studies of normal and disease states where the possibility of heterogeneity in metabolite T1 values between both chest muscle and heart and normal and disease states exists, the properties of saturation factors for metabolite ratios were investigated theoretically under conditions applicable in typical cardiac spectroscopy exams and empirically using data from 82 cardiac 31P exams in six study groups comprising normal controls ( n = 19) and patients with dilated ( n = 20) and hypertrophic ( n = 5) cardiomyopathy, coronary artery disease ( n = 16), heart transplants ( n = 19), and valvular heart disease ( n = 3). When TR ≪ T1,(PCr), with T1(PCr) ⩾ T1(ATP), the saturation factor for PCr/ATP lies in the range 1.5 ± 0.5, regardless of the T1 values. The precise value depends on the ratio of metabolite T1 values rather than their absolute values and is insensitive to modest changes in TR. Published data suggest that the metabolite T1 ratio is the same in heart and muscle. Our empirical data reveal that the saturation factors do not vary significantly with disease state, nor with the relative fractions of muscle and heart contributing to the chest surface-coil spectra. Also, the corrected myocardial PCr/ATP ratios in each normal or disease state bear no correlation with the corresponding saturation factors nor the fraction of muscle in the unlocalized chest spectra. However, application of the saturation correction (mean value, 1.36 ± 0.03 SE) significantly reduced scatter in myocardial PCr/ATP data by 14 ± 11% (SD) ( p ⩽ 0.05). The findings suggest that the relative T1 values of PCr and ATP are

  4. The consequences of long-term glycogen synthase kinase-3 inhibition on normal and insulin resistant rat hearts.

    Science.gov (United States)

    Flepisi, T B; Lochner, Amanda; Huisamen, Barbara

    2013-10-01

    Glycogen synthase kinase-3 (GSK-3) is a serine-threonine protein kinase, discovered as a regulator of glycogen synthase. GSK-3 may regulate the expression of SERCA-2a potentially affecting myocardial contractility. It is known to phosphorylate and inhibit IRS-1, thus disrupting insulin signalling. This study aimed to determine whether myocardial GSK-3 protein and its substrate proteins are dysregulated in obesity and insulin resistance, and whether chronic GSK-3 inhibition can prevent or reverse this. Weight matched male Wistar rats were rendered obese by hyperphagia using a special diet (DIO) for 16 weeks and compared to chow fed controls. Half of each group was treated with the GSK-3 inhibitor CHIR118637 (30 mg/kg/day) from week 12 to16 of the diet period. Biometric and biochemical parameters were measured and protein expression determined by Western blotting and specific antibodies. Ca(2+)ATPase activity was determined spectrophotometrically. Cardiomyocytes were prepared by collagenase perfusion and insulin stimulated 2-deoxy-glucose uptake determined. DIO rats were significantly heavier than controls, associated with increased intra-peritoneal fat and insulin resistance. GSK-3 inhibition did not affect weight but improved insulin resistance, also on cellular level. It had no effect on GSK-3 expression but elevated its phospho/total ratio and elevated IRS-2 expression. Obesity lowered SERCA-2a expression and activity while GSK-3 inhibition alleviated this. The phospho/total ratio of phospholamban underscored inhibition of SERCA-2a in obesity. In addition, signs of myocardial hypertrophy were observed in treated control rats. GSK-3 inhibition could not reverse all the detrimental effects of obesity but may be harmful in normal rat hearts. It regulates IRS-2, SERCA-2a and phospholamban expression but not IRS-1.

  5. 99mTc-glucarate kinetics differentiate normal, stunned, hibernating, and nonviable myocardium in a perfused rat heart model

    International Nuclear Information System (INIS)

    Okada, David R.; Liu, Zhonglin; Johnson, Gerald; Okada, Robert D.; Beju, Delia; Khaw, Ban An

    2010-01-01

    99m Tc-glucarate is an infarct-avid imaging agent. However, patients may have mixtures of normal, irreversibly injured, stunned, and hibernating myocardium. The purposes were to determine 99m Tc-glucarate uptake and clearance kinetics in these four conditions, and its ability to determine the extent of injury. Twenty-two perfused rat hearts were studied: controls (n = 5), stunned (n = 5; 20-min no-flow followed by 5-min reflow), hibernating (n = 6; 120-min low flow at 4 ml/min), and ischemic-reperfused (n = 6; 120-min no-flow followed by reflow). 99m Tc-glucarate was then infused. Tracer activity was monitored using a NaI scintillation detector and a multichannel analyzer. Creatine kinase, electron microscopy, and triphenyltetrazolium chloride determined viability. 99m Tc-glucarate 10-min myocardial uptake was significantly greater in ischemic-reperfused (2.50 ± 0.09) (cpm, SEM) than in control (1.74 ± 0.07), stunned (1.68 ± 0.11), and hibernating (1.59 ± 0.11) (p 99m Tc-glucarate 60-min myocardial uptake was significantly greater in ischemic-reperfused (7.60 ± 0.63) than in control (1.98 ± 0.15), stunned (1.79 ± 0.08), and hibernating (2.33 ± 0.15) (p 99m Tc-glucarate activity continually and progressively increased in irreversibly injured myocardium. 99m Tc-glucarate uptake was strongly correlated with myocardial necrosis as determined by three independent assessments of viability. There were minimal and similar 99m Tc-glucarate uptakes in control, stunned, and hibernating myocardium. (orig.)

  6. Progressive epicardial coronary blood flow reduction fails to produce ST-segment depression at normal heart rates.

    Science.gov (United States)

    de Chantal, Marilyn; Diodati, Jean G; Nasmith, James B; Amyot, Robert; LeBlanc, A Robert; Schampaert, Erick; Pharand, Chantal

    2006-12-01

    ST-segment depression is commonly seen in patients with acute coronary syndromes. Most authors have attributed it to transient reductions in coronary blood flow due to nonocclusive thrombus formation on a disrupted atherosclerotic plaque and dynamic focal vasospasm at the site of coronary artery stenosis. However, ST-segment depression was never reproduced in classic animal models of coronary stenosis without the presence of tachycardia. We hypothesized that ST-segment depression occurring during acute coronary syndromes is not entirely explained by changes in epicardial coronary artery resistance and thus evaluated the effect of a slow, progressive epicardial coronary artery occlusion on the ECG and regional myocardial blood flow in anesthetized pigs. Slow, progressive occlusion over 72 min (SD 27) of the left anterior descending coronary artery in 20 anesthetized pigs led to a 90% decrease in coronary blood flow and the development of ST-segment elevation associated with homogeneous and transmural myocardial blood flow reductions, confirmed by microspheres and myocardial contrast echocardiography. ST-segment depression was not observed in any ECG lead before the development of ST-segment elevation. At normal heart rates, progressive epicardial stenosis of a coronary artery results in myocardial ischemia associated with homogeneous, transmural reduction in regional myocardial blood flow and ST-segment elevation, without preceding ST-segment depression. Thus, in coronary syndromes with ST-segment depression and predominant subendocardial ischemia, factors other than mere increases in epicardial coronary resistance must be invoked to explain the heterogeneous parietal distribution of flow and associated ECG changes.

  7. Reflex control of heart rate in normal subjects in relation to age: a data base for cardiac vagal neuropathy

    NARCIS (Netherlands)

    Wieling, W.; van Brederode, J. F.; de Rijk, L. G.; Borst, C.; Dunning, A. J.

    1982-01-01

    We examined the heart rate changes induced by forced breathing and by standing up in 133 healthy subjects in the age range 10-65 years in order to establish a data base for studies on parasympathetic heart rate control in autonomic neuropathy. Test results declined with age. Log-transformation was

  8. The magnitude and course of exercise-induced stroke volume changes determine the exercise tolerance in heart transplant recipients with heart failure and normal ejection fraction

    Czech Academy of Sciences Publication Activity Database

    Meluzín, J.; Hude, P.; Leinveber, P.; Jurák, Pavel; Soukup, L.; Viščor, Ivo; Špinarová, L.; Štěpánová, R.; Podroužková, H.; Vondra, Vlastimil; Langer, P.; Němec, P.

    2014-01-01

    Roč. 20, č. 1 (2014), s. 674-687 ISSN 1205-6626 R&D Projects: GA MŠk(CZ) LO1212 Keywords : heart failure * stroke volume index * exercise tolerance * bioimpedance Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 0.758, year: 2013

  9. A New MRI-Based Model of Heart Function with Coupled Hemodynamics and Application to Normal and Diseased Canine Left Ventricles

    Science.gov (United States)

    Choi, Young Joon; Constantino, Jason; Vedula, Vijay; Trayanova, Natalia; Mittal, Rajat

    2015-01-01

    A methodology for the simulation of heart function that combines an MRI-based model of cardiac electromechanics (CE) with a Navier–Stokes-based hemodynamics model is presented. The CE model consists of two coupled components that simulate the electrical and the mechanical functions of the heart. Accurate representations of ventricular geometry and fiber orientations are constructed from the structural magnetic resonance and the diffusion tensor MR images, respectively. The deformation of the ventricle obtained from the electromechanical model serves as input to the hemodynamics model in this one-way coupled approach via imposed kinematic wall velocity boundary conditions and at the same time, governs the blood flow into and out of the ventricular volume. The time-dependent endocardial surfaces are registered using a diffeomorphic mapping algorithm, while the intraventricular blood flow patterns are simulated using a sharp-interface immersed boundary method-based flow solver. The utility of the combined heart-function model is demonstrated by comparing the hemodynamic characteristics of a normal canine heart beating in sinus rhythm against that of the dyssynchronously beating failing heart. We also discuss the potential of coupled CE and hemodynamics models for various clinical applications. PMID:26442254

  10. Radiographic imaging. 4 ed.

    International Nuclear Information System (INIS)

    Chesney, D.N.; Chesney, M.O.

    1981-01-01

    This is a revised edition of the textbook previously entitled 'Radiographic Photography' and accords with the current syllabus of training for the Diploma of the Royal College of Radiographers. The aim is a non-mathematical approach to provide a guide for the student to the knowledge and understanding of the theoretical concepts which affect the quality of radiographic image; materials and practices are also reviewed, particularly in relation to the characteristics of the radiographic image, and to processing equipment and processing areas. The subject is dealt with under the following headings: the photographic process, film materials in x-ray departments, sensitometry, storage of film materials and radiographs, intensifying screens and cassettes, film processing, developing, fixing, rinsing, washing, drying, the processing area and equipment, systems for daylight film handling, the radiographic image, management of the quality, presentation of the radiograph, light images and their recording, fluorography, some special imaging processes, e.g. xerography, copying radiographs. (U.K.)

  11. Low Left Atrial Compliance Contributes to the Clinical Recurrence of Atrial Fibrillation after Catheter Ablation in Patients with Structurally and Functionally Normal Heart.

    Science.gov (United States)

    Park, Junbeom; Yang, Pil-sung; Kim, Tae-Hoon; Uhm, Jae-Sun; Kim, Joung-Youn; Joung, Boyoung; Lee, Moon-Hyoung; Hwang, Chun; Pak, Hui-Nam

    2015-01-01

    Stiff left atrial (LA) syndrome was initially reported in post-cardiac surgery patients and known to be associated with low LA compliance. We investigated the physiological and clinical implications of LA compliance by estimating LA pulse pressure (LApp) among patients with atrial fibrillation (AF) and structurally and functionally normal heart. Among 1038 consecutive patients with LA pressure measurements before AF ablation, we included 334 patients with structurally and functionally normal heart (81.7% male, 54.1±10.6 years, 77.0% paroxysmal AF) after excluding those with hypertension, diabetes, and previous ablation or cardiac surgery. We measured LApp (peak-nadir LA pressure) at the beginning of the ablation procedure and compared the values with clinical parameters and the AF recurrence rate. AF patients with normal heart were younger and more frequently male and had paroxysmal AF, a lower body mass index, and a lower LApp compared to others (all p<0.05). Based on the median value, the low LA compliance group (LApp≥13 mmHg) had a smaller LA volume index and lower LA voltage (all p<0.05) compared to the high LA compliance group. During a mean follow-up of 16.7±11.8 months, low LA compliance was independently associated with two fold-higher risk of clinical AF recurrence (HR:2.202; 95%CI:1.077-4.503; p = 0.031). Low LA compliance, as determined by an elevated LApp, was associated with a smaller LA volume index and lower LA voltage and independently associated with higher clinical recurrence after catheter ablation in AF patients with structurally and functionally normal heart.

  12. {sup 99m}Tc-glucarate kinetics differentiate normal, stunned, hibernating, and nonviable myocardium in a perfused rat heart model

    Energy Technology Data Exchange (ETDEWEB)

    Okada, David R. [University of Pennsylvania School of Medicine, Philadelphia, PA (United States); Liu, Zhonglin [University of Arizona School of Medicine, Tucson, AZ (United States); Johnson, Gerald; Okada, Robert D. [University of Oklahoma Health Sciences Center, Oklahoma, OK (United States); University of Tulsa, Tulsa, OK (United States); Beju, Delia [Oklahoma State University School of Medicine, Tulsa, OK (United States); Khaw, Ban An [Northeastern University, Boston, MA (United States)

    2010-10-15

    {sup 99m}Tc-glucarate is an infarct-avid imaging agent. However, patients may have mixtures of normal, irreversibly injured, stunned, and hibernating myocardium. The purposes were to determine {sup 99m}Tc-glucarate uptake and clearance kinetics in these four conditions, and its ability to determine the extent of injury. Twenty-two perfused rat hearts were studied: controls (n = 5), stunned (n = 5; 20-min no-flow followed by 5-min reflow), hibernating (n = 6; 120-min low flow at 4 ml/min), and ischemic-reperfused (n = 6; 120-min no-flow followed by reflow). {sup 99m}Tc-glucarate was then infused. Tracer activity was monitored using a NaI scintillation detector and a multichannel analyzer. Creatine kinase, electron microscopy, and triphenyltetrazolium chloride determined viability. {sup 99m}Tc-glucarate 10-min myocardial uptake was significantly greater in ischemic-reperfused (2.50 {+-} 0.09) (cpm, SEM) than in control (1.74 {+-} 0.07), stunned (1.68 {+-} 0.11), and hibernating (1.59 {+-} 0.11) (p < 0.05). Tracer retention curves for ischemic-reperfused were elevated at all time points as compared with the other groups. {sup 99m}Tc-glucarate 60-min myocardial uptake was significantly greater in ischemic-reperfused (7.60 {+-} 0.63) than in control (1.98 {+-} 0.15), stunned (1.79 {+-} 0.08), and hibernating (2.33 {+-} 0.15) (p < 0.05). The 60-min well-counted tracer activity ratio of ischemic-reperfused to control was 9:1 and corroborated the NaI detector results. Creatine kinase, triphenyltetrazolium chloride, and electron microscopy all demonstrated significantly greater injury in ischemic-reperfused compared to the other groups. An excellent correlation was observed between viability markers and tracer activity (r = 0.99 triphenyltetrazolium chloride; r = 0.90 creatine kinase). {sup 99m}Tc-glucarate activity continually and progressively increased in irreversibly injured myocardium. {sup 99m}Tc-glucarate uptake was strongly correlated with myocardial necrosis as

  13. Determination of Sample Entropy and Fuzzy Measure Entropy Parameters for Distinguishing Congestive Heart Failure from Normal Sinus Rhythm Subjects

    Directory of Open Access Journals (Sweden)

    Lina Zhao

    2015-09-01

    Full Text Available Entropy provides a valuable tool for quantifying the regularity of physiological time series and provides important insights for understanding the underlying mechanisms of the cardiovascular system. Before any entropy calculation, certain common parameters need to be initialized: embedding dimension m, tolerance threshold r and time series length N. However, no specific guideline exists on how to determine the appropriate parameter values for distinguishing congestive heart failure (CHF from normal sinus rhythm (NSR subjects in clinical application. In the present study, a thorough analysis on the selection of appropriate values of m, r and N for sample entropy (SampEn and recently proposed fuzzy measure entropy (FuzzyMEn is presented for distinguishing two group subjects. 44 long-term NRS and 29 long-term CHF RR interval recordings from http://www.physionet.org were used as the non-pathological and pathological data respectively. Extreme (>2 s and abnormal heartbeat RR intervals were firstly removed from each RR recording and then the recording was segmented with a non-overlapping segment length N of 300 and 1000, respectively. SampEn and FuzzyMEn were performed for each RR segment under different parameter combinations: m of 1, 2, 3 and 4, and r of 0.10, 0.15, 0.20 and 0.25 respectively. The statistical significance between NSR and CHF groups under each combination of m, r and N was observed. The results demonstrated that the selection of m, r and N plays a critical role in determining the SampEn and FuzzyMEn outputs. Compared with SampEn, FuzzyMEn shows a better regularity when selecting the parameters m and r. In addition, FuzzyMEn shows a better relative consistency for distinguishing the two groups, that is, the results of FuzzyMEn in the NSR group were consistently lower than those in the CHF group while SampEn were not. The selections of m of 2 and 3 and r of 0.10 and 0.15 for SampEn and the selections of m of 1 and 2 whenever r (herein

  14. A radiographic study of mental foramen in intraoral radiographs

    International Nuclear Information System (INIS)

    Sohn, Jeong Ick; Choi, Karp Shik

    1995-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in periapical radiographs. For this study, periapical radiographs of premolar areas were obtained from the 200 adults. Accordingly, the positional and shape changes of mental foramen were evaluated. The authors obtained radiographs according to changes in radiation beam direction in periapical radiographs of premolar areas, and then evaluated the positional and shape changes of mental foramen. The following results were obtained: 1. Shapes of mental foramen were observed elliptical (34.3%), round or oval (28.0%), unidentified (25.5%) and diffuse (12.2%) type in descending order of frequency. 2, Horizontal positions of mental foramen were most frequently observed at the 2nd premolar area (55.3%), the area between the 1st premolar and 2nd premolar (39.6%), the area between the 2nd premolar and 1st molar (3.4%), the 1st premolar area (1.0%), the area between the canine and 1st premolar (0.7%) in descending order of frequency. 3. Vertical positions of mental foramen were most frequently observed at the inferior to apex (67.1%), and at apex (24.8%), overlap with apex (6.4%), superior to apex (1.7%) in descending order of frequency. 4. Shapes of mental foramen were more obviously observed at the upward 10 degree positioned periapical radiographs. And according to the changes of horizontal and vertical position, they were observed similar to normally positioned periapical radiographs.

  15. Chest radiographic findings in acute paraquat poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Na, Gyeong Gyun; Lee, Mi Sook; Kim, Hee Jun; Sun, In O [Presbyterian Medical Center, Jeonju (Korea, Republic of)

    2016-01-15

    To describe the chest radiographic findings of acute paraquat poisoning. 691 patients visited the emergency department of our hospital between January 2006 and October 2012 for paraquat poisoning. Of these 691, we identified 56 patients whose initial chest radiographs were normal but who developed radiographic abnormalities within one week. We evaluated their radiographic findings and the differences in imaging features based on mortality. The most common finding was diffuse consolidation (29/56, 52%), followed by consolidation with linear and nodular opacities (18/56, 32%), and combined consolidation and pneumomediastinum (7/56, 13%). Pleural effusion was noted in 17 patients (30%). The two survivors (4%) showed peripheral consolidations, while the 54 patients (96%) who died demonstrated bilateral (42/54, 78%) or unilateral (12/54, 22%) diffuse consolidations. Rapidly progressing diffuse pulmonary consolidation was observed within one week on follow-up radiographs after paraquat ingestion in the deceased, but the survivors demonstrated peripheral consolidation.

  16. Non-invasive estimation of myocardial efficiency using positron emission tomography and carbon-11 acetate - comparison between the normal and failing human heart

    International Nuclear Information System (INIS)

    Bengel, F.M.; Nekolla, S.; Schwaiger, M.; Ungerer, M.

    2000-01-01

    We studied ten patients with idiopathic dilated cardiomyopathy (DCM) and 11 healthy normals by dynamic PET with 11 C-acetate and either tomographic radionuclide ventriculography or cine magnetic resonance imaging. A ''stroke work index'' (SWI) was calculated by: SWI = systolic blood pressure x stroke volume/body surface area. To estimate myocardial efficiency, a ''work-metabolic index'' (WMI) was then obtained as follows: WMI = SWI x heart rate/k(mono), where k(mono) is the washout constant for 11 C-acetate derived from mono-exponential fitting. In DCM patients, left ventricular ejection fraction was 19%±10% and end-diastolic volume was 92±28 ml/m 2 (vs 64%±7% and 55±8 ml/m 2 in normals, P 2 ; P 6 mmHg x ml/m 2 ; P<0.001) were lower in DCM patients, too. Overall, the WMI correlated positively with ejection parameters (r=0.73, P<0.001 for ejection fraction; r=0.93, P<0.001 for stroke volume), and inversely with systemic vascular resistance (r=-0.77; P<0.001). There was a weak positive correlation between WMI and end-diastolic volume in normals (r=0.45; P=0.17), while in DCM patients, a non-significant negative correlation coefficient (r=-0.21; P=0.57) was obtained. In conclusion non-invasive estimates of oxygen consumption and efficiency in the failing heart were reduced compared with those in normals. Estimates of efficiency increased with increasing contractile performance, and decreased with increasing ventricular afterload. In contrast to normals, the failing heart was not able to respond with an increase in efficiency to increasing ventricular volume.(orig./MG) (orig.)

  17. Glucagon-like peptide-1 reduces contractile function and fails to boost glucose utilization in normal hearts in the presence of fatty acids.

    Science.gov (United States)

    Nguyen, T Dung; Shingu, Yasushige; Amorim, Paulo A; Schwarzer, Michael; Doenst, Torsten

    2013-10-09

    GLP-1 and exendin-4, which are used as insulin sensitizers or weight reducing drugs, were shown to improve glucose uptake in the heart. However, the direct effects of GLP-1 or exendin-4 on normal hearts in the presence of fatty acids, the main cardiac substrates, have never been investigated. We therefore assessed the effects of GLP-1 or exendin-4 on myocardial glucose uptake (GU), glucose oxidation (GO) and cardiac performance (CP) under conditions of fatty acid utilization. Rat hearts were perfused with only glucose (5 mM) or glucose (5 mM) plus oleate (0.4 mM) as substrates for 60 min. After 30 min, GLP-1 or exendin-4 (0.5 nM or 5 nM) was added. In the absence of oleate, GLP-1 increased both GU and GO. Exendin-4 increased GO but showed no effect on GU. Neither GLP-1 nor exendin-4 affected CP. However, when oleate was present, GLP-1 failed to stimulate glucose utilization and exendin-4 even decreased GU. Furthermore, now GLP-1 reduced CP. In contrast to prior reports, this negative inotropic effect could not be blocked by the protein kinase A inhibitor H-89. We then measured myocardial GO and CP in rats receiving a 4-week GLP-1 infusion. Interestingly, this chronic treatment resulted in a significant reduction in both GO and CP. Under the influence of oleate, GLP-1 reduces contractile function and fails to stimulate glucose utilization in normal hearts. Exendin-4 may acutely reduce cardiac glucose uptake but not contractility. We suggest advanced investigation of heart function and metabolism in patients treating with these peptides. © 2013.

  18. Quality of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    This chapter discussed on how to get a good radiograph. There are several factors that can make good radiograph such as density of radiograph, the contrast of radiograph, definition of radiograph, the present of artifact and backscattering. All of this factor will discuss detailed on each unit of chapter with some figure, picture to make the reader understand more when read this book. And at the end, the reader will introduce with penetrameter, one of device to determine the level of quality of the radiograph. There are two type of penetrameter like wire type or holes type. This standard must be followed by all the radiographer around the world to produce the good result that is standard and more reliable.

  19. RADIOGRAPHIC THORACIC ANATOMY OF THE RED PANDA (AILURUS FULGENS).

    Science.gov (United States)

    Makungu, Modesta; du Plessis, Wencke M; Barrows, Michelle; Groenewald, Hermanus B; Koeppel, Katja N

    2016-09-01

    The red panda ( Ailurus fulgens ) is classified as an endangered species by the International Union for Conservation of Nature and Natural Resources. The natural distribution of the red panda is in the Himalayas and southern China. Thoracic diseases such as dirofilariasis, hypertrophic cardiomyopathy, tracheal obstruction, lung worm infestation, and pneumonia have been reported in the red panda. The aim of this study was to describe the normal radiographic thoracic anatomy of captive red pandas as a species-specific reference for routine health examinations and clinical cases. Right lateral (RL) and dorsoventral (DV) inspiratory phase views of the thorax were obtained in 11 adult captive red pandas. Measurements were made and ratios calculated to establish reference ranges for the mean vertebral heart score on the RL (8.34 ± 0.25) and DV (8.78 ± 0.34) views and the mean ratios of the caudal vena cava diameter to the vertebral body length above tracheal bifurcation (0.67 ± 0.05) and tracheal diameter to the width of the third rib (2.75 ± 0.24). The majority of animals (10/11) had 14 thoracic vertebrae, except for one animal that had 15 thoracic vertebrae. Rudimentary clavicles were seen in 3/11 animals. The ovoid, oblique cardiac silhouette was more horizontally positioned and elongated in older animals. A redundant aortic arch was seen in the oldest animal. The trachea was seen with mineralized cartilage rings in all animals. The carina was clearly seen in the majority of animals (10/11). Variations exist in the normal radiographic thoracic anatomy of different species. Knowledge of the normal radiographic thoracic anatomy of the red panda should prove useful for routine health examinations and in the diagnosis of thoracic diseases.

  20. Radiation recommendation series: administratively required dental radiographs

    International Nuclear Information System (INIS)

    1981-09-01

    Administrative requirements for radiographs are found in many segments of the United States health care system. This document presents an FDA radiation recommendation on administratively required dental x-ray examinations. In general, such examinations are not requested to further the patient's dental health, but rather as a means of monitoring claims. However, the administrative use of radiographs that have been taken in the normal course of patient care is usually appropriate, as long as the patient's right to privacy is respected

  1. Reconstruction and Visualization of Fiber and Laminar Structure in the Normal Human Heart from Ex Vivo DTMRI Data

    International Nuclear Information System (INIS)

    Rohmer, Damien; Sitek, Arkadiusz; Gullberg, Grant T.

    2006-01-01

    Background--The human heart is composed of a helical network of muscle fibers. These fibers are organized to form sheets that are separated by cleavage surfaces. This complex structure of fibers and sheets is responsible for the orthotropic mechanical properties of cardiac muscle. The understanding of the configuration of the 3D fiber and sheet structure is important for modeling the mechanical and electrical properties of the heart and changes in this configuration maybe of significant importance to understand the remodeling after myocardial infarction. Methods--Anisotropic least square filtering followed by fiber and sheet tracking techniques were applied to Diffusion Tensor Magnetic Resonance Imaging (DTMRI) data of the excised human heart. The fiber configuration was visualized by using thin tubes to increase 3-dimensional visual perception of the complex structure. The sheet structures were reconstructed from the DTMRI data, obtaining surfaces that span the wall from the endo- to the epicardium. All visualizations were performed using the high-quality ray-tracing software POV-Ray. Results--The fibers are shown to lie in sheets that have concave or convex transmural structure which correspond to histological studies published in the literature. The fiber angles varied depending on the position between the epi- and endocardium. The sheets had a complex structure that depended on the location within the myocardium. In the apex region the sheets had more curvature. Conclusions--A high-quality visualization algorithm applied to demonstrated high quality DTMRI data is able to elicit the comprehension of the complex 3 dimensional structure of the fibers and sheets in the heart

  2. Reconstruction and Visualization of Fiber and Laminar Structure inthe Normal Human Heart from Ex Vivo DTMRI Data

    Energy Technology Data Exchange (ETDEWEB)

    Rohmer, Damien; Sitek, Arkadiusz; Gullberg, Grant T.

    2006-12-18

    Background - The human heart is composed of a helicalnetwork of muscle fibers. These fibers are organized to form sheets thatare separated by cleavage surfaces. This complex structure of fibers andsheets is responsible for the orthotropic mechanical properties ofcardiac muscle. The understanding of the configuration of the 3D fiberand sheet structure is important for modeling the mechanical andelectrical properties of the heart and changes in this configuration maybe of significant importance to understand the remodeling aftermyocardial infarction.Methods - Anisotropic least square filteringfollowed by fiber and sheet tracking techniques were applied to DiffusionTensor Magnetic Resonance Imaging (DTMRI) data of the excised humanheart. The fiber configuration was visualized by using thin tubes toincrease 3-dimensional visual perception of the complex structure. Thesheet structures were reconstructed from the DTMRI data, obtainingsurfaces that span the wall from the endo- to the epicardium. Allvisualizations were performed using the high-quality ray-tracing softwarePOV-Ray. Results - The fibers are shown to lie in sheets that haveconcave or convex transmural structure which correspond to histologicalstudies published in the literature. The fiber angles varied depending onthe position between the epi- and endocardium. The sheets had a complexstructure that depended on the location within the myocardium. In theapex region the sheets had more curvature. Conclusions - A high-qualityvisualization algorithm applied to demonstrated high quality DTMRI datais able to elicit the comprehension of the complex 3 dimensionalstructure of the fibers and sheets in the heart.

  3. Fast radiographic systems

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1984-08-01

    Industrial radiography can be performed with shorter exposure times, when instead of X-ray film with lead intensifying screens the radiographic paper with fluorescent screen is used. With paper radiography one can obtain lower material, equipment, and labor costs, shorter exposure and processing times, and easier radiation protection. The speed of the radiographic inspection can also be increased by the use of fluorometallic intensifying screens together with a special brand of X-ray film. Before accepting either of the two fast radiographic systems one must be sure that they can produce radiographs of adequate image quality. Therefore an investigation was performed on that subject using ISO wire IQI's and ASTM penetrameters. The radiographic image quality was tested for aluminium and steel up to 30 mm thick using various brands of radiographic paper and X-ray film with fluorometallic screens and comparing them with fast X-ray films with lead screens. Both systems give satisfactory results. (author)

  4. Serum bilirubin and antioxidant levels in first degree relatives of patients with ischemic heart disease and normal subjects

    International Nuclear Information System (INIS)

    Mahmood, N.; Naseem, T.; Mukhtar, F.; Basheer, R.

    2011-01-01

    Background: Coronary diseases appear to result from an overbalance between radical-generating, compared with radical-scavenging systems, a condition called as oxidative stress. Total antioxidant status (TAS) in human plasma reflects the balance between oxidants and antioxidants in each system. Bilirubin has been considered an antioxidant, with capacity to remove reactive species of oxygen. Present study tried to measure the total antioxidant status of first degree relatives of patients with IHD. Study also tried to evaluate the prognostic role of serum bilirubin in disease prevention or progression. Methods: Seventy five apparently healthy subjects in age group 20-50 years, comprising equal number of males and females, who were first degree relatives of ischemic heart disease patients, were included in the study. Family members were divided on the bases of their numbers, i.e., one family member (Group-A), 2 family members (Group-B) and more than 3 family members (Group-C). Study was cross sectional and carried out in a period of 6 months (Jun 2008-Jan 2009). Subjects with letter of consent were taken from general population. Seventy five healthy age matched people with no history of ischemic heart disease in family were taken as control. An overnight fasting blood sample was taken. Total antioxidant status was determined using a commercially available kit. Serum bilirubin was estimated by auto analyzer. Results: Family history of ischemic heart disease with serum bilirubin showed a significant negative correlation (p<0.05). But the values of TAS failed to show any significant correlation with the family history. It was observed that the value of serum bilirubin was decreased significantly (p<0.05) with an increased number of family members. Total antioxidant status failed to show any significant difference among all the three groups. Conclusion: Our data demonstrated that reduced serum levels of bilirubin were seen in people with a higher prevalence of coronary

  5. Radiographic constant exposure technique

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1985-01-01

    The constant exposure technique has been applied to assess various industrial radiographic systems. Different X-ray films and radiographic papers of two producers were compared. Special attention was given to fast film and paper used with fluorometallic screens. Radiographic image quality...... was tested by the use of ISO wire IQI's and ASTM penetrameters used on Al and Fe test plates. Relative speed and reduction of kilovoltage obtained with the constant exposure technique were calculated. The advantages of fast radiographic systems are pointed out...

  6. Visual simulation of radiographs

    International Nuclear Information System (INIS)

    Laguna, G.

    1985-01-01

    A method for computer simulation of radiographs has been added to the LLNL version of the solid modeler TIPS-1 (Technical Information Processing System-1). This new tool will enable an engineer to compare an actual radiograph of a solid to its computer-generated counterpart. The appearance of discrepancies between the two can be an indication of flaws in the solid object. Simulated radiographs can also be used to preview the placement of x-ray sources to focus on areas of concern before actual radiographs are made

  7. Effects of Hyponatremia Normalization on the Short-Term Mortality and Rehospitalizations in Patients with Recent Acute Decompensated Heart Failure: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    Renato De Vecchis

    2016-10-01

    Full Text Available Background: Several studies have shown that hyponatremia is associated with increased risk of rehospitalization and death in patients with heart failure. In these studies, chronic heart failure (CHF patients with persistent hyponatremia were compared only with CHF patients with a normal sodium level at hospital admission. Aims: In the present retrospective study, conducted in a cohort of patients with recent acute decompensated heart failure (ADHF, all with hyponatremia ascertained at the time of hospital admission, we aimed to evaluate the effect of the normalization of serum sodium on the composite endpoint of short-term rehospitalization and mortality. Methods: A retrospective study centered on medical records of patients hospitalized for ADHF in the period April 2013 to April 2016 was performed. Data regarding serum sodium measurements had to be collected from medical records of cardiology wards of two hospitals, and were then processed for statistical analysis. As an inclusion criterion for enrollment, patients had to be suffering from heart failure that had required at least one hospitalization. Moreover, they had to be suffering from a state of hyponatremia (serum sodium < 135 mEq/L at admission on the occasion of the index hospitalization. Patients with hyponatremia at admission were divided into two groups, one comprising patients with hyponatremia that persisted at the time of discharge (persistent hyponatremia and a second including patients who had achieved normalization of their serum sodium levels (serum Na+ ≥ 135 mEq/L during hospitalization until discharge. For both groups, the risk of mortality and rehospitalization during a 30-day follow-up was assessed. Results: One hundred and sixty CHF patients with various degrees of functional impairment were enrolled in the study. Among them, 56 (35% had persistent hyponatremia over the course of hospitalization. At multivariable Cox proportional-hazards regression analysis, the risk of

  8. Prognostic Value of Normal Perfusion but Impaired Left Ventricular Function in the Diabetic Heart on Quantitative Gated Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hwanjeong; Choi, Sehun; Han, Yeonhee [Research Institute of Chonbuk National Univ. Medical School and Hospitial, Jeonju (Korea, Republic of); Lee, Dong Soo; Lee, Hoyoung; Chung, Junekey [Seoul National Univ., Seoul (Korea, Republic of)

    2013-09-15

    This study aimed at identifying the predictive parameters on quantitative gated myocardial perfusion single-photon emission computed tomography (QG-SPECT) in diabetic patients with normal perfusion but impaired function. Methods Among the 533 consecutive diabetic patients, 379 patients with normal perfusion on rest Tl-201/dipyridamole-stress Tc-{sup 99m} sestamibi Gated SPECT were enrolled. Patients were grouped into those with normal post-stress left ventricular function (Group I) and those with impaired function (EF <50 or impaired regional wall motion, Group II). We investigated cardiac events and cause of death by chart review and telephone interview. Survival analysis and Cox proportional hazard model analysis were performed. Between the Group I and II, cardiac events as well as chest pain symptoms, smoking, diabetic complications were significantly different (P<0.05). On survival analysis, event free survival rate in Group II was significantly lower than in Group I (P=0.016). In univariate Cox proportional hazard analysis on overall cardiac event, Group (II over I), diabetic nephropathy, summed motion score (SMS), summed systolic thickening score (STS), numbers of abnormal segmental wall motion and systolic thickening predicted more cardiac events (P<0.05). Multivariate analysis showed that STS was the only independent predictor cardiac event. The functional parameter, especially summed systolic thickening score on QG-SPECT had prognostic values, despite normal perfusion, in predicting cardiac events in diabetic patients, and QG-SPECT provides clinically useful risk stratification in diabetic patients with normal perfusion.

  9. Legalities of the radiograph

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The radiograph itself plays a major role in medical malpractice cases. Also, many questions arise concerning the rights to and storage of x-ray films. These issues are addressed in this chapter. To keep the terminology simple, the word radiograph represents all imaging documentation on hard copy film (x-rays, nuclear medicine, computer-assisted studies, ultrasound, and magnetic resonance imaging)

  10. Analysis of Morphological Characteristics and Origins of Idiopathic Premature Ventricular Contractions Under a 12-Lead Electrocardiogram in Children with Structurally Normal Hearts.

    Science.gov (United States)

    Jiang, Jianbin; He, Yuee; Qiu, Huixian; Zhang, Yuanhai; Chu, Maoping; Li, Yuechun; Chen, Qi

    2017-10-21

    Up to 40% of healthy children have premature ventricular complexes or contractions (PVCs) detected with 24-hour Holter monitoring. We aimed to investigate the morphological characteristics and origins of idiopathic PVCs under a 12-lead electrocardiogram in children with structurally normal hearts. All asymptomatic monomorphic PVC patients with structurally normal hearts under 18 years of age were included in this retrospective study. Characteristics of PVCs in lead V 1 under a 12-lead electrocardiogram were classified as left bundle branch block (PVC-LBBB) or right bundle branch block (PVC-RBBB). According to limb leads, PVC-LBBB or PVC-RBBB was divided into: PVCs-LBBB type I; PVCs-LBBB type II; PVCs-RBBB type I; PVCs-RBBB type II; and PVCs-RBBB type III. Out of 178 PVC patients, 94 cases of PVCs-LBBB (PVCs-LBBB type I = 60; PVCs-LBBB type II = 34) and 84 cases of PVCs-RBBB (PVCs-RBBB type I = 3; PVCs-RBBB type II = 55; PVCs-RBBB type III = 26) were identified. The frequency of PVCs-LBBB type I increased with age and the frequency of PVCs-RBBB type II and III decreased with age. Among the children monitor tested, from 1 years old to 18 years old, PVCs originating from the left or right ventricular outflow tract gradually increased with age, while PVCs originating from the branch sources decreased with age.

  11. Modulation of the Rho/ROCK pathway in heart and lung after thorax irradiation reveals targets to improve normal tissue toxicity.

    Science.gov (United States)

    Monceau, Virginie; Pasinetti, Nadia; Schupp, Charlotte; Pouzoulet, Fred; Opolon, Paule; Vozenin, Marie-Catherine

    2010-11-01

    The medical options available to prevent or treat radiation-induced injury are scarce and developing effective countermeasures is still an open research field. In addition, more than half of cancer patients are treated with radiation therapy, which displays a high antitumor efficacy but can cause, albeit rarely, disabling long-term toxicities including radiation fibrosis. Progress has been made in the definition of molecular pathways associated with normal tissue toxicity that suggest potentially effective therapeutic targets. Targeting the Rho/ROCK pathway seems a promising anti-fibrotic approach, at least in the gut; the current study was performed to assess whether this target was relevant to the prevention and/or treatment of injury to the main thoracic organs, namely heart and lungs. First, we showed activation of two important fibrogenic pathways (Smad and Rho/ROCK) in response to radiation-exposure to adult cardiomyocytes; we extended these observations in vivo to the heart and lungs of mice, 15 and 30 weeks post-irradiation. We correlated this fibrogenic molecular imprint with alteration of heart physiology and long-term remodelling of pulmonary and cardiac histological structures. Lastly, cardiac and pulmonary radiation injury and bleomycin-induced pulmonary fibrosis were successfully modulated using Rho/ROCK inhibitors (statins and Y-27632) and this was associated with a normalization of fibrogenic markers. In conclusion, the present paper shows for the first time, activation of Rho/ROCK and Smad pathways in pulmonary and cardiac radiation-induced delayed injury. Our findings thereby reveal a safe and efficient therapeutic opportunity for the abrogation of late thoracic radiation injury, potentially usable either before or after radiation exposure; this approach is especially attractive in (1) the radiation oncology setting, as it does not interfere with prior anti-cancer treatment and in (2) radioprotection, as applicable to the treatment of established

  12. Modulation of the ρ/rock pathway in heart and lung after thorax irradiation reveals targets to improve normal tissue toxicity

    International Nuclear Information System (INIS)

    Monceau, V.; Pasinetti, N.; Schupp, C.; Pouzoulet, F.; Opolon, P.; Vozenin, M.C.

    2010-01-01

    The medical options available to prevent or treat radiation-induced injury are scarce and developing effective countermeasures is still an open research field. In addition, more than half of cancer patients are treated with radiation therapy, which displays a high antitumor efficacy but can cause, albeit rarely, disabling long-term toxicities including radiation fibrosis. Progress has been made in the definition of molecular pathways associated with normal tissue toxicity that suggest potentially effective therapeutic targets. Targeting the Rho/ROCK pathway seems a promising anti-fibrotic approach, at least in the gut; the current study was performed to assess whether this target was relevant to the prevention and/or treatment of injury to the main thoracic organs, namely heart and lungs. First, we showed activation of two important fibro-genic pathways (Smad and Rho/ROCK) in response to radiation-exposure to adult cardio-myocytes; we extended these observations in vivo to the heart and lungs of mice, 15 and 30 weeks post-irradiation. We correlated this fibro-genic molecular imprint with alteration of heart physiology and long-term remodelling of pulmonary and cardiac histological structures. Lastly, cardiac and pulmonary radiation injury and bleomycin-induced pulmonary fibrosis were successfully modulated using Rho/ROCK inhibitors (statins and Y-27632) and this was associated with a normalization of fibro-genic markers. In conclusion, the present paper shows for the first time, activation of Rho/ROCK and Smad pathways in pulmonary and cardiac radiation-induced delayed injury. Our findings thereby reveal a safe and efficient therapeutic opportunity for the abrogation of late thoracic radiation injury, potentially usable either before or after radiation exposure; this approach is especially attractive in (1) the radiation oncology setting, as it does not interfere with prior anti-cancer treatment and in (2) radioprotection, as applicable to the treatment of

  13. Inferior hilar window on lateral chest radiographs

    International Nuclear Information System (INIS)

    Park, C.K.; Webb, W.R.; Klein, J.S.

    1990-01-01

    This paper determines the accuracy of lateral chest radiography in the detection of masses in the inferior hilar window, a normally avascular hilar region anterior to the lower lobe bronchi. Fifty patients with normal thoracic CT scans and 25 with hilar masses/adenopathy were selected retrospectively. The 75 corresponding lateral chest radiographs were blindly evaluated for visibility of the anterior walls of the lower lobe bronchi and the presence and laterality of abnormal soft tissue (>1 cm) in the inferior hilar window. Only a 7 x 7-cm square of the lateral radiograph was viewed

  14. XYLITOL IMPROVES ANTI-OXIDATIVE DEFENSE SYSTEM IN SERUM, LIVER, HEART, KIDNEY AND PANCREAS OF NORMAL AND TYPE 2 DIABETES MODEL OF RATS.

    Science.gov (United States)

    Chukwuma, Chika Ifeanyi; Islam, Shahidul

    2017-05-01

    The present study investigated the anti-oxidative effects of xylitol both in vitro and in vivo in normal and type 2 diabetes (T2D) rat model. Free radical scavenging and ferric reducing potentials of different concentrations of xylitol were investigated in vitro. For in vivo study, six weeks old male Sprague-Dawley rats were divided into four groups, namely: Normal Control (NC), Diabetic Control (DBC), Normal Xylitol (NXYL) and Diabetic Xylitol (DXYL). T2D was induced in the DBC and DXYL groups. After the confirmation of diabetes, a 10% xylitol solution was supplied instead of drinking water to NXYL and DXYL, while normal drinking water was supplied to NC and DBC ad libitum. After five weeks intervention period, the animals were sacri- ficed and thiobarbituric acid reactive substances (TBARS) and reduced glutathione (GSH) concentrations as well as superoxide dismutase, catalase glutathione reductase and glutathione peroxidase activities were determined in the liver, heart, kidney, pancreatic tissues and serum samples. Xylitol exhibited significant (p foods and food products.

  15. Detection of myocardial 123I-BMIPP distribution abnormality in patients with ischemic heart disease based on normal data file in Bull's-eye polar map

    International Nuclear Information System (INIS)

    Takahashi, Nobukazu; Ishida, Yoshio; Hirose, Yoshiaki; Kawano, Shigeo; Fukuoka, Syuji; Hayashida, Kohei; Takamiya, Makoto; Nonogi, Hiroshi

    1995-01-01

    Visual interpretation of 123 I-BMIPP (BMIPP) myocardial images has difficulties in detecting mild reduction in tracer uptake. We studied the significance of the objective assessment of myocardial BMIPP maldistributions at rest by using a Bull's-eye map and its normal data file for detecting ischemic heart disease. Twenty nine patients, 15 with prior myocardial infarction and 14 with effort angina were studied. The initial 15-min BMIPP image was evaluated by visual analysis and by generating the extent Bull's-eye map which exhibits regions with reduced % uptake under mean-2SD of 10 normal controls. The sensitivity for determining coronary lesions in non-infarcted myocardial regions with the extent map was superior to that with visual analysis (67% vs. 33%). In the regions supplied by the stenotic coronary artery, those which showed visually negative but positive in the map and which showed positive in both had higher incidence of wall motion abnormalities and severe coronary stenosis than those with normal findings in both. These results suggest that the objective assessment based on the normal data file in a Bull's-eye polar map is clinically important for improving the limitation or the visual interpretation in 123 I-BMIPP imaging. (author)

  16. Effect of mental challenge induced by movie clips on action potential duration in normal human subjects independent of heart rate.

    Science.gov (United States)

    Child, Nicholas; Hanson, Ben; Bishop, Martin; Rinaldi, Christopher A; Bostock, Julian; Western, David; Cooklin, Michael; O'Neil, Mark; Wright, Matthew; Razavi, Reza; Gill, Jaswinder; Taggart, Peter

    2014-06-01

    Mental stress and emotion have long been associated with ventricular arrhythmias and sudden death in animal models and humans. The effect of mental challenge on ventricular action potential duration (APD) in conscious healthy humans has not been reported. Activation recovery intervals measured from unipolar electrograms as a surrogate for APD (n=19) were recorded from right and left ventricular endocardium during steady-state pacing, whilst subjects watched an emotionally charged film clip. To assess the possible modulating role of altered respiration on APD, the subjects then repeated the same breathing pattern they had during the stress, but without the movie clip. Hemodynamic parameters (mean, systolic, and diastolic blood pressure, and rate of pressure increase) and respiration rate increased during the stressful part of the film clip (P=0.001). APD decreased during the stressful parts of the film clip, for example, for global right ventricular activation recovery interval at end of film clip 193.8 ms (SD, 14) versus 198.0 ms (SD, 13) during the matched breathing control (end film left ventricle 199.8 ms [SD, 16] versus control 201.6 ms [SD, 15]; P=0.004). Respiration rate increased during the stressful part of the film clip (by 2 breaths per minute) and was well matched in the respective control period without any hemodynamic or activation recovery interval changes. Our results document for the first time direct recordings of the effect of a mental challenge protocol on ventricular APD in conscious humans. The effect of mental challenge on APD was not secondary to emotionally induced altered respiration or heart rate. © 2014 American Heart Association, Inc.

  17. Xeroradiographic and radiographic anatomy of the channel catfish, Ictalurus punctatus

    International Nuclear Information System (INIS)

    Smith, S.A.; Smith, B.J.

    1994-01-01

    The purpose of this study was to provide an anatomic reference for the channel catfish (Ictalurus punctatus) using xeroradiography† and conventional radiography. The entire body of three adult fish was radiographed using standard xeroradiographic and conventional radiographic techniques. Two xeroradiographs and their corresponding conventional radiographs were selected, and the xeroradiographs labeled to illustrate the normal skeletal and soft-tissue anatomy of the channel catfish

  18. Producing quality radiographic images

    International Nuclear Information System (INIS)

    Cullinan, A.M.

    1987-01-01

    This book gives an overview of physics, equipment, imaging, and quality assurance in the radiology department. The chapters are laid out with generous use of subheads to allow for quick reference, Points are illustrated with clear, uncluttered line diagrams and well-produced images. The accompanying explanations are miniature lessons by themselves. Inserted at various points throughout the text are important notes that highlight key concepts. The chapter ''Image Evaluation and Application of Radiographic Principles'' present a systematic approach to evaluating radiographs and contains several sample radiographs to illustrate the points made

  19. 4D flow MRI assessment of right atrial flow patterns in the normal heart - influence of caval vein arrangement and implications for the patent foramen ovale.

    Directory of Open Access Journals (Sweden)

    Jehill D Parikh

    Full Text Available To investigate atrial flow patterns in the normal adult heart, to explore whether caval vein arrangement and patency of the foramen ovale (PFO may be associated with flow pattern.Time-resolved, three-dimensional velocity encoded magnetic resonance imaging (4D flow was employed to assess atrial flow patterns in thirteen healthy subjects (6 male, 40 years, range 25-50 and thirteen subjects (6 male, 40 years, range 21-50 with cryptogenic stroke and patent foramen ovale (CS-PFO. Right atrial flow was defined as vortical, helico-vortical, helical and multiple vortices. Time-averaged and peak systolic and diastolic flows in the caval and pulmonary veins and their anatomical arrangement were compared.A spectrum of right atrial flow was observed across the four defined categories. The right atrial flow patterns were strongly associated with the relative position of the caval veins. Right atrial flow patterns other than vortical were more common (p = 0.015 and the separation between the superior and inferior vena cava greater (10±5mm versus 3±3mm, p = 0.002 in the CS-PFO group. In the left atrium all subjects except one had counter-clockwise vortical flow. Vortex size varied and was associated with left lower pulmonary vein flow (systolic r = 0.61, p = 0.001, diastolic r = 0.63 p = 0.002. A diastolic vortex was less common and time-averaged left atrial velocity was greater in the CS-PFO group (17±2cm/sec versus 15±1, p = 0.048. One CS-PFO subject demonstrated vortical retrograde flow in the descending aortic arch; all other subjects had laminar descending aortic flow.Right atrial flow patterns in the normal heart are heterogeneous and are associated with the relative position of the caval veins. Patterns, other than 'typical' vortical flow, are more prevalent in the right atrium of those with cryptogenic stroke in the context of PFO. Left atrial flow patterns are more homogenous in normal hearts and show a relationship with flow arising from the left

  20. Initial image interpretation of appendicular skeletal radiographs: A comparison between nurses and radiographers

    International Nuclear Information System (INIS)

    Piper, Keith J.; Paterson, Audrey

    2009-01-01

    Purpose: To examine the effect of a short training programme on nurses and radiographers, exploring differences between their performance before and after training. Method: Twenty-two nurses and 18 radiographers interpreted 20 trauma radiographs of the appendicular skeleton before and after training. Normal and abnormal cases of a discriminatory nature were included. Total score, sensitivity and specificity values were calculated for each participant by comparison with an agreed expected answer. The area under the curve (AUC) was analysed using alternate free-response receiver operating characteristic (AFROC) methodology. Results: Significant differences were demonstrated between the total scores achieved by the two groups (pre-training: p = 0.007, post-training: p = 0.04). After training, the mean score increased significantly for both groups (p < 0.001). No significant difference was found between the radiographers mean pre-training scores and the nurses mean post-training scores (p = 0.66). Sensitivity for both groups increased following training, significantly so for the nurses (nurses: p < 0.001, radiographers: p = 0.06). Specificity reduced significantly after training for the nurses (p < 0.001), and increased for the radiographers but not significantly (p = 0.085). After training, there was no significant difference between the two groups in terms of sensitivity (p = 0.09) but specificity was significantly higher for the radiographers (p < 0.001). The radiographers achieved higher pre-training AUC values than the nurses (p = 0.04), although a difference remained after training this did not achieve statistical significance (p = 0.15). The AUC values increased significantly after training for both groups (nurses: p = 0.012, radiographers: p = 0.004) and again there was no significant difference between the radiographers pre-training performance and the nurses post-training performance (p = 0.62). Conclusion: Improvement after training was seen in both groups

  1. Radiographic signs and diagnosis of dental disease

    International Nuclear Information System (INIS)

    Bellows, J.

    1993-01-01

    Dental radiographs are critical for the complete assessment and treatment of dental diseases. Dental radiography is commonly used to evaluate congenital dental defects, periodontal disease, orthodontic manipulations, oral tumors, endodontic treatments, oral trauma, and any situation where an abnormality is suspected. Although standard radiographic equipment and film can be used to produce dental radiographs, dental X-ray equipment and film provide superior quality images and greater convenience of animal patient positioning. An understanding of normal dental radiographic anatomy is important when interpreting dental radiographs. Stage III periodontitis is the earliest stage of periodontal disease at which radiographic abnormalities become apparent. Bone loss associated with periodontal disease can be classified as either horizontal or vertical. Periapical radiolucencies can represent granulomas, cysts, or abscesses, whereas periapical radiodensities may represent sclerotic bone or condensing osteitis. Lytic lesions of the bone of the jaw often represent oral neoplasms. Neoplasms also can displace or disrupt teeth in the dental arch. Resorptive lesions can be external or internal and appear as radiolucent areas involving the external surface of the root or the pulp cavity, respectively. Feline dental resorptive lesions, also known as odontoclastic resorptions, are a specific form of dental resorptive lesions unique to cats

  2. Radiographer performed single contrast small bowel enteroclysis

    International Nuclear Information System (INIS)

    Law, Robert L.; Slack, Nicola; Harvey, Richard F.

    2005-01-01

    Aim: To analyse the technical success and reporting sensitivity of radiographer performed small bowel enteroclysis (SBE) undertaken by a specialist radiographer according to a standard technique [Nolan DJ, Cadman PJ. The small bowel enema made easy. Clinical Radiology 1987;38(3):295-301]. Methods: Patients (1413) had 1646 SBE in 10 years from May 1992 to April 2002. The original request card and the separate radiographer and consultant radiologist reports were reviewed. Where the radiology reports were discordant or inconclusive, the clinical notes were also reviewed. Results: Patients (1022) X-ray films were available. Nine hundred and forty-three (93.3%) SBEs had been successfully completed. Radiographer and consultant radiologist reporting had a 99.3% concordance. There was a 98.4% sensitivity for Crohn's disease (181 of 184 cases where Crohn's disease was the clinical final diagnosis). Overall reporting sensitivity was 93.7% although correct 'probably normal and abnormal' reporting bias suggests a sensitivity of 96.9%. Sixty of 943 (6.4%) reports were inconclusive. Of 1022 patients, 68 (6.6%) of small bowel intubations were not achieved, or else consent was withdrawn at the time of the procedure. Conclusion: Specialist radiographers can perform small bowel enteroclysis with a reporting sensitivity equal to that of a consultant radiologist. Radiographers accustomed to providing an SBE service become skilled at passing fine bore feeding tubes into the small bowel and can provide this service also

  3. Rapidly processable radiographic material

    International Nuclear Information System (INIS)

    Brabandere, L.A. de; Borginon, H.A.; Pattyn, H.A.; Pollet, R.J.

    1981-01-01

    A new rapidly processable radiographic silver halide material is described for use in mammography and non-destructive testing of industrial materials. The radiographic material is used for direct exposure to penetrating radiation without the use of fluorescent-intensifying screens. It consists of a transparent support with a layer of hydrophilic colloid silver halide emulsion on one or both sides. Examples of the preparation of three different silver halide emulsions are given including the use of different chemical sensitizers. These new radiographic materials have good resistance to the formation of pressure marks in rapid processing apparatus and they have improved sensitivity for direct exposure to penetrating radiation compared to conventional radiographic emulsions. (U.K.)

  4. Radiographic manifestations of hypochondroplasia

    Energy Technology Data Exchange (ETDEWEB)

    Heselson, N G; Cremin, B J [Groote Schuur Hospital, Cape Town (South Africa); Beighton, P

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations.

  5. Thoracic radiographic anatomy in goats | Makungu | Tanzania ...

    African Journals Online (AJOL)

    The aim of this study was to describe the normal radiographic anatomy of the thorax of small East African goats as a reference for clinical use. Radiography of the thorax was performed under general anaesthesia in 10 healthy small East African goats. Right lateral (RL), left lateral (LL), dorsoventral (DV) and ventrodorsal ...

  6. Prevalence of symptomatic heart failure with reduced and with normal ejection fraction in an elderly general population-the CARLA study.

    Directory of Open Access Journals (Sweden)

    Daniel Tiller

    Full Text Available BACKGROUND/OBJECTIVES: Chronic heart failure (CHF is one of the most important public health concerns in the industrialized world having increasing incidence and prevalence. Although there are several studies describing the prevalence of heart failure with reduced ejection fraction (HFREF and heart failure with normal ejection fraction (HFNEF in selected populations, there are few data regarding the prevalence and the determinants of symptomatic heart failure in the general population. METHODS: Cross-sectional data of a population-based German sample (1,779 subjects aged 45-83 years were analyzed to determine the prevalence and determinants of chronic SHF and HFNEF defined according to the European Society of Cardiology using symptoms, echocardiography and serum NT-proBNP. Prevalence was age-standardized to the German population as of December 31st, 2005. RESULTS: The overall age-standardized prevalence of symptomatic CHF was 7.7% (95%CI 6.0-9.8 for men and 9.0% (95%CI 7.0-11.5 for women. The prevalence of CHF strongly increased with age from 3.0% among 45-54- year-old subjects to 22.0% among 75-83- year-old subjects. Symptomatic HFREF could be shown in 48% (n = 78, symptomatic HFNEF in 52% (n = 85 of subjects with CHF. The age-standardized prevalence of HFREF was 3.8 % (95%CI 2.4-5.8 for women and 4.6 % (95%CI 3.6-6.3 for men. The age-standardized prevalence of HFNEF for women and men was 5.1 % (95%CI 3.8-7.0 and 3.0 % (95%CI 2.1-4.5, respectively. Persons with CHF were more likely to have hypertension (PR = 3.4; 95%CI 1.6-7.3 or to have had a previous myocardial infarction (PR = 2.5, 95%CI 1.8-3.5. CONCLUSION: The prevalence of symptomatic CHF appears high in this population compared with other studies. While more women were affected by HFNEF than men, more male subjects suffered from HFREF. The high prevalence of symptomatic CHF seems likely to be mainly due to the high prevalence of cardiovascular risk factors in this population.

  7. A radiographic study of the position and shape of mental foramen in panoramic radiographs

    International Nuclear Information System (INIS)

    Choi, Karp Shik; Kim, Dong Youn; Sohn, Jeong Ick; Bae, Yong Chul

    1997-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in panoramic radiographs. For this study, panoramic radiographs were obtained from the 200 adults and evaluated the position and shape of mental foramen. According to various positional changes in panoramic radiographs of the patients, the author also obtained panoramic radiographs from the 100 adults and then evaluated the positional and shape changes of mental foramen. The following results were obtained : 1. Shapes of mental foramen were observed elliptical (43.3%), round or oval (42.5%), unidentified (7.5%) and diffuse (6.7%) type in descending order of frequency. 2. Horizontal position of mental foramen were most frequently observed at the 2nd premolar area (54.2%), and area between the 1st premolar and 2nd premolar (43.1%), area between the 2nd premolar and 1st molar (2.7%), and at apex (9.7%), overlap with apex (1.9%), superior of apex (0.2%) in descending order of frequency. 4. According to various positional changes in panoramic radiographs of the patients, shape changes of mental foramen were more obviously observed at the forward 10 mm and chin down 10 degree positioned panoramic radiographs, And changes of horizontal and vertical position were observed in similar to compared with normal positioned panoramic radiographs.

  8. Normal foot and ankle

    International Nuclear Information System (INIS)

    Weissman, S.D.

    1989-01-01

    The foot may be thought of as a bag of bones tied tightly together and functioning as a unit. The bones re expected to maintain their alignment without causing symptomatology to the patient. The author discusses a normal radiograph. The bones must have normal shape and normal alignment. The density of the soft tissues should be normal and there should be no fractures, tumors, or foreign bodies

  9. International normalized ratio self-management lowers the risk of thromboembolic events after prosthetic heart valve replacement.

    Science.gov (United States)

    Eitz, Thomas; Schenk, Soren; Fritzsche, Dirk; Bairaktaris, Andreas; Wagner, Otto; Koertke, Heinrich; Koerfer, Reiner

    2008-03-01

    Although prosthetic valves are durable and easy to implant, the need for lifetime warfarin-based anticoagulation restricts their exclusive usage. We investigated if anticoagulation self-management improves outcome in a single-center series. Between 1994 and 1998, 765 patients with prosthetic valve replacements were prospectively enrolled and randomized to receive conventional anticoagulation management by their primary physician (group 1, n = 295) or to pursue anticoagulation self-management (group 2, n = 470). A study head office was implemented to coordinate and monitor anticoagulation protocols, international normalized ratios (INR), and adverse events. Patients were instructed on how to obtain and test their own blood samples and to adjust warfarin dosages according to the measured INR (target range, 2.5 to 4). Mean INR values were slightly yet significantly smaller in group 1 than in group 2 (2.8 +/- 0.7 vs 3.0 +/- .6, p events were similar in both groups. Time-related multivariate analysis identified INR self-management and higher INR as independent predictors for better outcome. Anticoagulation self-management can improve INR profiles up to 2 years after prosthetic valve replacement and reduce adverse events. Current indications of prosthetic rather than biologic valve implantations may be extended if the benefit of INR self-management is shown by future studies with longer follow-up.

  10. Radiographic findings in the chest of patients following cardiac transplantation

    International Nuclear Information System (INIS)

    Shirazi, K.K.; Amendola, M.A.; Tisnado, J.; Cho, S.R.; Beachley, M.C.; Lower, R.R.

    1983-01-01

    The postoperative chest radiographic findings in 38 patients undergoing orthotopic (37 patients) and heterotopic (1 patient) cardiac transplantation were evaluated. Findings were correlated with those of echocardiograms, sputum and blood cultures, and lung and heart biopsies. The radiographic manifestations in the chest of these patients are classified in the following three main categories: 1) newly formed cardiac silhouette findings due to the transplanted heart itself, i.e., changes in size and shape of the new heart and pericardial effusion resulting from the placement of a smaller heart in a larger pericardial sac. 2) infectious complications due to bacteria, fungal, and other opportunistic agents secondary to immunosuppressive therapy, and 3) usual postoperatice complications following thoracomoty and open-heart surgery. (orig.)

  11. Revisiting the slow force response: the role of the PKG signaling pathway in the normal and the ischemic heart.

    Science.gov (United States)

    Castro-Ferreira, Ricardo; Neves, João Sérgio; Ladeiras-Lopes, Ricardo; Leite-Moreira, André M; Neiva-Sousa, Manuel; Almeida-Coelho, João; Ferreira-Martins, João; F Leite-Moreira, Adelino

    2014-09-01

    The myocardial response to acute stretch consists of a two-phase increase in contractility: an acute increase by the Frank-Starling mechanism and a gradual and time-dependent increase in force generated known as the slow force response (SFR). The SFR is actively modulated by different signaling pathways, but the role of protein kinase G (PKG) signaling is unknown. In this study we aim to characterize the role of the PKG signaling pathway in the SFR under normal and ischemic conditions. Rabbit papillary muscles were stretched from 92 to 100% of maximum length (Lmax) under basal conditions, in the absence (1) or presence of: a PKG agonist (2) and a PKG inhibitor (3); under ischemic conditions in the absence (4) or presence of: a PKG agonist (5); a nitric oxide (NO) donor (6) and a phosphodiesterase 5 (PDE5) inhibitor (7). Under normoxia, the SFR was significantly attenuated by inhibition of PKG and remained unaltered with PKG activation. Ischemia induced a progressive decrease in myocardial contractility after stretch. Neither the PKG agonist nor the NO donor altered the myocardial response to stretch under ischemic conditions. However, the use of a PDE5 inhibitor in ischemia partially reversed the progressive deterioration in contractility. PKG activity is essential for the SFR. During ischemia, a progressive decline in the force is observed in response to acute myocardial stretch. This dysfunctional response can be partially reversed by the use of PDE5 inhibitors. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  12. Pelvic radiograph in skeletal dysplasias: An approach

    Directory of Open Access Journals (Sweden)

    Manisha Jana

    2017-01-01

    Full Text Available The bony pelvis is constituted by the ilium, ischium, pubis, and sacrum. The pelvic radiograph is an important component of the skeletal survey performed in suspected skeletal dysplasia. Most of the common skeletal dysplasias have either minor or major radiological abnormalities; hence, knowledge of the normal radiological appearance of bony pelvis is vital for recognizing the early signs of various skeletal dysplasias. This article discusses many common and some uncommon radiological findings on pelvic radiographs along with the specific dysplasia in which they are seen; common differential diagnostic considerations are also discussed.

  13. Diagnosis of calcification on abdominal radiographs

    International Nuclear Information System (INIS)

    Lamb, C.R.; Kleine, L.J.; McMillan, M.C.

    1991-01-01

    A wide variety of normal and pathologic factors may induce intraabdominal calcification. In general, the most reliable indication of the cause of a calcification is its location; therefore, if the affected organ can be identified the radiographic diagnosis is often straightforward or, at least, limited to relatively few possibilities. With this principle in mind, a series of patients with abdominal calcification are described for the purpose of illustrating the appearance of calcification of various abdominal organs. In addition, etiology for the calcification in each patient is discussed. Certain extraabdominal calcifications which may be seen on abdominal radiographs are also mentioned

  14. Telemedicine-guided, very low-dose international normalized ratio self-control in patients with mechanical heart valve implants.

    Science.gov (United States)

    Koertke, Heinrich; Zittermann, Armin; Wagner, Otto; Secer, Songuel; Sciangula, Alfonso; Saggau, Werner; Sack, Falk-Udo; Ennker, Jürgen; Cremer, Jochen; Musumeci, Francesco; Gummert, Jan F

    2015-06-01

    To study in patients performing international normalized ratio (INR) self-control the efficacy and safety of an INR target range of 1.6-2.1 for aortic valve replacement (AVR) and 2.0-2.5 for mitral valve replacement (MVR) or double valve replacement (DVR). In total, 1304 patients undergoing AVR, 189 undergoing MVR and 78 undergoing DVR were randomly assigned to low-dose INR self-control (LOW group) (INR target range, AVR: 1.8-2.8; MVR/DVR: 2.5-3.5) or very low-dose INR self-control once a week (VLO group) and twice a week (VLT group) (INR target range, AVR: 1.6-2.1; MVR/DVR: 2.0-2.5), with electronically guided transfer of INR values. We compared grade III complications (major bleeding and thrombotic events; primary end-points) and overall mortality (secondary end-point) across the three treatment groups. Two-year freedom from bleedings in the LOW, VLO, and VLT groups was 96.3, 98.6, and 99.1%, respectively (P = 0.008). The corresponding values for thrombotic events were 99.0, 99.8, and 98.9%, respectively (P = 0.258). The risk-adjusted composite of grade III complications was in the per-protocol population (reference: LOW-dose group) as follows: hazard ratio = 0.307 (95% CI: 0.102-0.926; P = 0.036) for the VLO group and = 0.241 (95% CI: 0.070-0.836; P = 0.025) for the VLT group. The corresponding values of 2-year mortality were = 1.685 (95% CI: 0.473-5.996; P = 0.421) for the VLO group and = 4.70 (95% CI: 1.62-13.60; P = 0.004) for the VLT group. Telemedicine-guided very low-dose INR self-control is comparable with low-dose INR in thrombotic risk, and is superior in bleeding risk. Weekly testing is sufficient. Given the small number of MVR and DVR patients, results are only valid for AVR patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  15. A Low-Normal Free Triiodothyronine Level Is Associated with Adverse Prognosis in Euthyroid Patients with Heart Failure Receiving Cardiac Resynchronization Therapy.

    Science.gov (United States)

    Chen, Yu-Yang; Shu, Xiao-Rong; Su, Zi-Zhuo; Lin, Rong-Jie; Zhang, Hai-Feng; Yuan, Wo-Liang; Wang, Jing-Feng; Xie, Shuang-Lun

    2017-12-12

    Thyroid dysfunction is prevalent in patients with heart failure (HF) and hypothyroidism is related to the adverse prognosis of HF subjects receiving cardiac resynchronization therapy (CRT). We aim to investigate whether low-normal free triiodothyronine (fT3) level is related to CRT response and the prognosis of euthyroid patients with HF after CRT implantation.One hundred and thirteen euthyroid patients who received CRT therapy without previous thyroid disease and any treatment affecting thyroid hormones were enrolled. All of patients were evaluated for cardiac function and thyroid hormones (serum levels of fT3, free thyroxine [fT4] and thyroid-stimulating hormone [TSH]). The end points were overall mortality and hospitalization for HF worsening. During a follow-up period of 39 ± 3 weeks, 36 patients (31.9%) died and 45 patients (39.8%) had hospitalization for HF exacerbation. A higher rate of NYHA III/IV class and a lower fT3 level were both observed in death group and HF event group. Multivariate Cox regression analyses disclosed that a lower-normal fT3 level (HR = 0.648, P = 0.009) and CRT response (HR = 0.441, P = 0.001) were both independent predictors of overall mortality. In addition, they were also both related to HF re-hospitalization event (P < 0.01 for both). Patients with fT3 < 3.00 pmol/L had a significantly higher overall mortality than those with fT3 ≥ 3.00 pmol/L (P = 0.027). Meanwhile, a higher HF hospitalization event rate was also found in patients with fT3 < 3.00 pmol/L (P < 0.001).A lower-normal fT3 level is correlated with a worse cardiac function an adverse prognosis in euthyroid patients with HF after CRT implantation.

  16. Chest radiograph interpretation by medical students

    International Nuclear Information System (INIS)

    Jeffrey, D.R.; Goddard, P.R.; Callaway, M.P.; Greenwood, R.

    2003-01-01

    AIM: To assess the ability of final year medical students to interpret conventional chest radiographs. MATERIALS AND METHODS: Ten conventional chest radiographs were selected from a teaching hospital radiology department library that were good radiological examples of common conditions. All were conditions that a medical student should be expected to recognize by the end of their training. One normal radiograph was included. The radiographs were shown to 52 final year medical students who were asked to describe their findings. RESULTS: The median score achieved was 12.5 out of 20 (range 6-18). There was no difference between the median scores of male and female students (12.5 and 12.3, respectively, p=0.82) but male students were more likely to be certain of their answers than female students (median certainty scores 23.0 and 14.0, respectively). The overall degree of certainty was low. On no radiograph were more than 25% of students definite about their answer. Students had received little formal radiology teaching (2-42 h, median 21) and few expressed an interest in radiology as a career. Only two (3.8%) students thought they were good at interpreting chest radiographs, 17 (32.7%) thought they were bad or awful. CONCLUSION: Medical students reaching the end of their training do not perform well at interpreting simple chest radiographs. They lack confidence and have received little formal radiological tuition. Perhaps as a result, few are interested in radiology as a career, which is a matter for concern in view of the current shortage of radiologists in the UK

  17. Horizontal fissure on neonatal plain chest radiographs: clinical implications

    International Nuclear Information System (INIS)

    Konarzewska, J.; Zawadzka-Kepczynska, A.; Bianek-Bodzak, A.; Kawinska-Kilianczyk, A.; Domzalska-Popadiuk, I.

    2005-01-01

    Regardless of etiology, pleural fluid, even in small amounts, can be visualized on the neonatal chest x-ray picture within pulmonary fissures. It remains unclear whether a marked horizontal fissure unaccompanied by any other radiological symptoms is of diagnostic value or not. Ninety-one consecutive neonatal chest radiographs with marked horizontal fissure were retrospectively analyzed. The images were made between 1999 and 2005 on 69 newborns admitted to the Neonatology Department, Institute of Obstetrics and Gynecology, Medical University of Gdansk. Analysis of the radiographs was conducted independently by three radiologists based on the following criteria: fissure thickness (marked or thickened), bronchovascular markings (increased or normal), size and shape of the heart (normal or abnormal), presence or absence of pulmonary infiltration, atelectasis, and changes related to wet lung syndrome. Due to divergent interpretations, the ultimate interpretation was established by consensus in 25 cases. The radiological findings were compared with clinical data. The compatibility of the three independent interpreters was statistically significant (p<0.0001). Marked transverse fissure was the only radiological finding on 66 x-rays. In 63 cases (69.2%) the children were asymptomatic as well. In 3 cases (3.3%) clinical symptoms of respiratory tract infection occurred. On the other 25 images, horizontal fissure was accompanied by other radiological symptoms. Chest x-ray results corresponded with clinical symptoms in 24 cases (26.4%). One child (1.1%) with radiological evidence of wet lung syndrome did not present any typical clinical symptoms of it. Horizontal fissure noted on a neonatal chest x-ray seems to be of minor diagnostic value if not accompanied by any other radiological symptoms. (author)

  18. Radiographic aspects of xeroradiography

    International Nuclear Information System (INIS)

    Rao, G.U.V.; Fatouros, P.P.

    1980-01-01

    The quality of a conventional radiographic image can be characterized in terms of five basic parameters; density, contrast, latitude, resolution and noise. Since xeroradiographic images exhibit very limited broad area contrasts, and image formation is predominantly due to edge enhancement, a straightforward description of image quality using the same five parameters is not adequate. A detailed study was made of the radiographic aspects of xeroradiography with special reference to mammography, and a summary of major findings to date with appropriate references to published papers is presented

  19. Comparisons of radiographic and electrocardiographic abnormalities in canine heartworm disease

    International Nuclear Information System (INIS)

    Calvert, C.A.; Losonsky, J.M.; Brown, J.; Lewis, R.E.

    1986-01-01

    Thoracic radiographs and electrocardiograms from 137 dogs with heartworm infection were independently evaluated and comparisons were made of (1) the presence or absence of right ventricular enlargement as assessed by these two diagnostic tests and (2) the presence or absence of right-sided congestive heart failure relative to the degree of right ventricular enlargement and ECG criteria of RVH. Radiographic evidence of severe, but not moderate, right ventricular enlargement was associated with right-sided congestive heart failure. Similarly the presence of three or more, but not fewer than three, ECG criteria of RVH were associated with right-sided congestive heart failure. If either the thoracic radiographs or the ECG indicated that severe right ventricular enlargement was absent, right-sided congestive heart failure was seldom present. The most accurate correlation of the radiographic evaluation of severe right ventricular enlargement was afforded by the presence of three or more ECG criteria of RVH. ECG criteria of RVH such as R/S v4 , + T v10 MEA x , and S 11 are highly specific tests; while S V2 is a highly sensitive but not highly specific test. The ECG is a good confirmation test of the presence of severe right ventricular enlargement and is a good exclusion test for the absence of right-sided congestive heart failure. (author)

  20. Radiographic identification of the equine ventral conchal bulla.

    Science.gov (United States)

    Finnegan, C M; Townsend, N B; Barnett, T P; Barakzai, S Z

    Involvement of the ventral conchal sinus (VCS) is an important diagnostic and prognostic feature in cases of the equine sinus disease. The authors aimed to ascertain if the caudo-dorsal extension of the VCS, the ventral conchal bulla (VCB) is identifiable on plain radiographs of cadaver skulls without sinus disease. Bilateral frontonasal sinus flaps were made in 10 equine cadaver skulls. Plain lateral, lateral oblique and dorso-ventral radiographs were then obtained followed by the same views taken with stainless steel wire outlining the caudal border of the VCB. Plain radiographs were randomised and blindly evaluated by two observers who marked where they believed the VCB to be positioned. This was then correlated with the true position of the VCB using radiographs with wires in place. The ease of identification of the VCB was classified as 'easy' or 'difficult'. The VCB was correctly identified in 70 per cent of lateral radiographs, but only 45 per cent of lateral oblique radiographs and 17 per cent of dorso-ventral radiographs. If a clinician was confident that he or she could identify the VCB, they were usually correct. Conversely if the clinician judged VCB identification as 'difficult', they usually identified it incorrectly. In the authors' clinical experience, the VCB of horses with sinusitis involving this compartment is more radiologically evident than in clinically normal horses. Knowledge of the normal radiographic anatomy of this structure should aid clinicians in identifying horses with sinusitis affecting the VCS.

  1. Nondestructive examination - radiographic techniques

    International Nuclear Information System (INIS)

    Maier, H.J.

    1980-01-01

    First the basic principles of radiography are to be treated, especially the different radiation sources (X-ray, gamma-ray, neutrons, heat). In the second part those radiographic methods are shown, which are in common use for technical purposes, especially under the aspect of flaw recognition. (orig./RW)

  2. Matching hand radiographs

    NARCIS (Netherlands)

    Kauffman, J.A.; Slump, Cornelis H.; Bernelot Moens, H.J.

    2005-01-01

    Biometric verification and identification methods of medical images can be used to find possible inconsistencies in patient records. Such methods may also be useful for forensic research. In this work we present a method for identifying patients by their hand radiographs. We use active appearance

  3. Stabilized radiographic scanning agent

    International Nuclear Information System (INIS)

    Fawzi, M.B.

    1979-01-01

    A stable composition useful in preparation of technetium-99m-based radiographic scanning agents has been developed. The composition contains a stabilizing amount of gentisate stabilizer selected from gentisic acid and its soluble pharmaceutically-acceptable salts and esthers. (E.G.)

  4. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Tofe, A.J.

    1976-01-01

    A stable radiographic scanning agent on a sup(99m)Tc basis has been developed. The substance contains a pertechnetate reduction agent, tin(II)-chloride, chromium(II)-chloride, or iron(II)-sulphate, as well as an organospecific carrier and ascorbic acid or a pharmacologically admissible salt or ester of ascorbic acid. (VJ) [de

  5. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  6. Dimensional analysis of heart rate variability in heart transplant recipients

    Energy Technology Data Exchange (ETDEWEB)

    Zbilut, J.P.; Mayer-Kress, G.; Geist, K.

    1987-01-01

    We discuss periodicities in the heart rate in normal and transplanted hearts. We then consider the possibility of dimensional analysis of these periodicities in transplanted hearts and problems associated with the record.

  7. Exercise training normalizes renal blood flow responses to acute hypoxia in experimental heart failure: role of the α1-adrenergic receptor.

    Science.gov (United States)

    Pügge, Carolin; Mediratta, Jai; Marcus, Noah J; Schultz, Harold D; Schiller, Alicia M; Zucker, Irving H

    2016-02-01

    Recent data suggest that exercise training (ExT) is beneficial in chronic heart failure (CHF) because it improves autonomic and peripheral vascular function. In this study, we hypothesized that ExT in the CHF state ameliorates the renal vasoconstrictor responses to hypoxia and that this beneficial effect is mediated by changes in α1-adrenergic receptor activation. CHF was induced in rabbits. Renal blood flow (RBF) and renal vascular conductance (RVC) responses to 6 min of 5% isocapnic hypoxia were assessed in the conscious state in sedentary (SED) and ExT rabbits with CHF with and without α1-adrenergic blockade. α1-adrenergic receptor expression in the kidney cortex was also evaluated. A significant decline in baseline RBF and RVC and an exaggerated renal vasoconstriction during acute hypoxia occurred in CHF-SED rabbits compared with the prepaced state (P renal denervation (DnX) blocked the hypoxia-induced renal vasoconstriction in CHF-SED rabbits. α1-adrenergic protein in the renal cortex of animals with CHF was increased in SED animals and normalized after ExT. These data provide evidence that the acute decline in RBF during hypoxia is caused entirely by the renal nerves but is only partially mediated by α1-adrenergic receptors. Nonetheless, α1-adrenergic receptors play an important role in the beneficial effects of ExT in the kidney. Copyright © 2016 the American Physiological Society.

  8. Radiographic progession of rheumatoid arthritis

    International Nuclear Information System (INIS)

    Siozos, C.D.

    1981-01-01

    The radiographic progression of rheumatoid arthritis can be graded on a 0-IV scala. For this purpose five objective criteria are used: a) destruction, b) osteoporosis, c) narrowing of joint space, d) luxation and e) ankylosis. The grading of the radiographic progression is defined by the extent and the number of the measured alterations. The radiographic progression can be registered yearly. (orig.) [de

  9. Probabilities of Pulmonary and Cardiac Complications and Radiographic Parameters in Breast Cancer Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Noh, O Kyu; Paek, Sung Ho; Ahn, Seung Do; Choi, Eun Kyung; Lee, Sang Wook; Song, Si Yeol; Yoon, Sang Min; Kim, Jong Hoon [Dept. of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2010-11-15

    To evaluate the relationship between the normal tissue complication probability (NTCP) of 3- dimensional (3-D) radiotherapy and the radiographic parameters of 2-dimensional (2-D) radiotherapy such as central lung distance (CLD) and maximal heart distance (MHD). We analyzed 110 patients who were treated with postoperative radiotherapy for breast cancer. A two-field tangential technique, a three-field technique, and the reverse hockey stick method were used. The radiation dose administered to whole breast or the chest wall was 50.4 Gy, whereas a 45 Gy was administered to the supraclavicular field. The NTCPs of the heart and lung were calculated by the modified Lyman model and the relative seriality model. For all patients, the NTCPs of radiation-induced pneumonitis and cardiac mortality were 0.5% and 0.7%, respectively. The NTCP of radiation-induced pneumonitis was higher in patients treated with the reverse hockey stick method than in those treated by other two techniques (0.0%, 0.0%, 3.1%, p<0.001). The NTCP of radiation-induced pneumonitis increased with CLD. The NTCP of cardiac mortality increased with MHD (R2=0.808). We found a close correlation between the NTCP of 3-D radiotherapy and 2-D radiographic parameters. Our results are useful to reanalyze the previous 2-D based clinical reports about breast radiation therapy complications as a viewpoint of NTCP.

  10. Probabilities of Pulmonary and Cardiac Complications and Radiographic Parameters in Breast Cancer Radiotherapy

    International Nuclear Information System (INIS)

    Noh, O Kyu; Paek, Sung Ho; Ahn, Seung Do; Choi, Eun Kyung; Lee, Sang Wook; Song, Si Yeol; Yoon, Sang Min; Kim, Jong Hoon

    2010-01-01

    To evaluate the relationship between the normal tissue complication probability (NTCP) of 3- dimensional (3-D) radiotherapy and the radiographic parameters of 2-dimensional (2-D) radiotherapy such as central lung distance (CLD) and maximal heart distance (MHD). We analyzed 110 patients who were treated with postoperative radiotherapy for breast cancer. A two-field tangential technique, a three-field technique, and the reverse hockey stick method were used. The radiation dose administered to whole breast or the chest wall was 50.4 Gy, whereas a 45 Gy was administered to the supraclavicular field. The NTCPs of the heart and lung were calculated by the modified Lyman model and the relative seriality model. For all patients, the NTCPs of radiation-induced pneumonitis and cardiac mortality were 0.5% and 0.7%, respectively. The NTCP of radiation-induced pneumonitis was higher in patients treated with the reverse hockey stick method than in those treated by other two techniques (0.0%, 0.0%, 3.1%, p<0.001). The NTCP of radiation-induced pneumonitis increased with CLD. The NTCP of cardiac mortality increased with MHD (R2=0.808). We found a close correlation between the NTCP of 3-D radiotherapy and 2-D radiographic parameters. Our results are useful to reanalyze the previous 2-D based clinical reports about breast radiation therapy complications as a viewpoint of NTCP.

  11. Optic densitometry in radiographic images to evaluate nutritional secondary hyperparathyroidism in kittens

    International Nuclear Information System (INIS)

    Rahal, S.C.; Mortari, A.C.; Caporali, E.H.G.; Vulcano, L.C.; Santos, F.A.M. dos; Takahira, R.K.; Crocci, A.J.

    2002-01-01

    The aim of this study was to evaluate the modification of bone mineral density, as well as the serum biochemistry variation in the nutritional secondary hyperparathyroidism. Ten crossbreed cats, initial aging between 2 and 3 months, and weighing 820 grams were used. After 10 days of adaptation, they were fed with raw beef heart for 60 days. At the end of adaptation time and every 15 days, exams were realized. The method of optical densitometry in radiographic images of the right radius and ulna was used. There was no statistical difference in the bone mineral densitometry between the end of adaptation period and with 15 days of consuming a diet of beef heart. At 30 days the bone density decreased statistically, and it was in the same level at 45 and 60 days. There was no statistical difference in the serum calcium and phosphorus concentrations in all observation time. Serum alkaline phosphatase concentration varied and it was increased above normal variation in the 45 th and 60 th day of the diet. It was possible to conclude that bone densitometry in radiographic images is an efficient method to evaluate bone demineralization, and calcium, phosphorus and alkaline phosphatase serum biochemistry analysis are limited value [pt

  12. Modeling dental radiographic systems

    International Nuclear Information System (INIS)

    Webber, R.L.

    1980-01-01

    The Bureau of Radiological Health has been actively collaborating with the Clinical Investigations Branch, NIDR, in applied research involving diagnostic use of ionizing radiation in dentistry. This work has centered on the search for alternatives to conventional radiographic systems in an attempt to improve diagnostic performance while reducing the required exposure. The basic approach involves analysis of factors limiting performance of properly defined diagnostic tasks and the modeling alternative systems with an eye toward increasing objective measures of performance. Previous collaborative work involved using a nonlinear model to compare various x-ray spectra. The data were expressed as brightness-contrast versus exposure for simulated tasks of clinical interest. This report supplements these findings by extending the number of parameters under investigation and modifying the mode of data display so that an actual radiographic image can be simulated on a television screen

  13. Reestablishment of radiographic kidney size in Miniature Schnauzer dogs.

    Science.gov (United States)

    Sohn, Jungmin; Yun, Sookyung; Lee, Jeosoon; Chang, Dongwoo; Choi, Mincheol; Yoon, Junghee

    2017-01-10

    Kidney size may be altered in renal diseases, and the detection of kidney size alteration has diagnostic and prognostic values. We hypothesized that radiographic kidney size, the kidney length to the second lumbar vertebra (L2) length ratio, in normal Miniature Schnauzer dogs may be overestimated due to their shorter vertebral length. This study was conducted to evaluate radiographic and ultrasonographic kidney size and L2 length in clinically normal Miniature Schnauzers and other dog breeds to evaluate the effect of vertebral length on radiographic kidney size and to reestablish radiographic kidney size in normal Miniature Schnauzers. Abdominal radiographs and ultrasonograms from 49 Miniature Schnauzers and 54 other breeds without clinical evidence of renal disease and lumbar vertebral abnormality were retrospectively evaluated. Radiographic kidney size, in the Miniature Schnauzer (3.31 ± 0.26) was significantly larger than that in other breeds (2.94 ± 0.27). Relative L2 length, the L2 length to width ratio, in the Miniature Schnauzer (1.11 ± 0.06) was significantly shorter than that in other breeds (1.21 ± 0.09). However, ultrasonographic kidney sizes, kidney length to aorta diameter ratios, were within or very close to normal range both in the Miniature Schnauzer (6.75 ± 0.67) and other breeds (7.16 ± 1.01). Thus, Miniature Schnauzer dogs have breed-specific short vertebrae and consequently a larger radiographic kidney size, which was greater than standard reference in normal adult dogs. Care should be taken when evaluating radiographic kidney size in Miniature Schnauzers to prevent falsely diagnosed renomegaly.

  14. Radiographic findings in immunodeficiency

    International Nuclear Information System (INIS)

    Obregon, R.; Lynch, D.A.; Cink, T.M.; Newell, J.D.; Kirkpatrick, C.

    1991-01-01

    This paper reviews the chest radiographs and high-resolution CT (HRCT) scans in patients with immunodeficiency disorders and define the role of HRCT. Thirty-three cases were retrospectively graded according to the consensus of two radiologists. Patients with HIV seropositivity and asthma were excluded. HRCT was performed in 12 cases with standard techniques. Diagnoses included common variable hypogammaglobulinemia (n = 19), X-linked agammaglobulinemia (n = 4), chronic mucocutaneous candidiasis (n = 4), and selective immunoglobulin g deficiencies (n = 2). Chest radiographs showed bronchiectasis in 11 of 33 cases with a predominant lower lobe distribution (82%). Nodules were present in six cases and mucus plugs in four cases. HRCT showed bronchiectasis in nine of 12 cases; in five of these nine cases, bronchiectasis was not apparent on chest radiographs. Other HRCT findings included segmental air trapping (four of 12), mucus plugs (three of 12), hazy consolidation (four of 12), nodules (five of 12), and bronchiolectasis (two of 12). Therapy was altered in seven of 12 cases in which HRCT was performed. Most pertinent to clinical management were the presence of a thymoma (n = 1) and severe focal of diffuse bronchiectasis

  15. Large Format Radiographic Imaging

    International Nuclear Information System (INIS)

    Rohrer, J. S.; Stewart, Lacey; Wilke, M. D.; King, N. S.; Baker A, S.; Lewis, Wilfred

    1999-01-01

    Radiographic imaging continues to be a key diagnostic in many areas at Los Alamos National Laboratory (LANL). Radiographic recording systems have taken on many form, from high repetition-rate, gated systems to film recording and storage phosphors. Some systems are designed for synchronization to an accelerator while others may be single shot or may record a frame sequence in a dynamic radiography experiment. While film recording remains a reliable standby in the radiographic community, there is growing interest in investigating electronic recording for many applications. The advantages of real time access to remote data acquisition are highly attractive. Cooled CCD camera systems are capable of providing greater sensitivity with improved signal-to-noise ratio. This paper begins with a review of performance characteristics of the Bechtel Nevada large format imaging system, a gated system capable of viewing scintillators up to 300 mm in diameter. We then examine configuration alternatives in lens coupled and fiber optically coupled electro-optical recording systems. Areas of investigation include tradeoffs between fiber optic and lens coupling, methods of image magnification, and spectral matching from scintillator to CCD camera. Key performance features discussed include field of view, resolution, sensitivity, dynamic range, and system noise characteristics

  16. Radiographic testing of wood

    International Nuclear Information System (INIS)

    Osterloh, K.; Zscherpel, U.; Raedel, C.; Weidemann, G.; Meinel, D.; Goebbels, J.; Ewert, U.; Hasenstab, A.; Buecherl, T.

    2007-01-01

    Wood is an old and established consumption and construction material. It is still the most common material for constructing furniture, roofs, playgrounds and mine supports. In contrast to steel and concrete, wood warns of extreme loads by creaking. Its mechanical stability is more influenced by decay than by peripheral cracks. While external cracks are visible, internal decay by fungus growth is undetectable from outside. This may be a safety problem in supporting structures. The best analysis of the internal structure is provided by computed tomography, but this is also the most complex method, much more so than simple radiographic testing. However, the latter is made inaccurate by scattered radiation resulting from internal moisture. With the image processing options of digital radiographic techniques, the structural information can be separated effectively from noise. In contrast to X-ray and gamma radiography, neutron radiography provides information on the spatial distribution of moisture. In healthy wood, water is conducted in the sapwood while the hardwood is dry. Moisture in hardwood is caused by infestations, e.g. fungus growth. The contribution presents a comparative analysis of the available radiographic methods. (orig.)

  17. Radiograph identifying means

    International Nuclear Information System (INIS)

    Sheldon, A.D.

    1983-01-01

    A flexible character-indentable plastics embossing tape is backed by and bonded to a lead strip, not more than 0.025 inches thick, to form a tape suitable for identifying radiographs. The lead strip is itself backed by a relatively thin and flimsy plastics or fabric strip which, when removed, allows the lead plastic tape to be pressure-bonded to the surface to be radiographed. A conventional tape-embossing gun is used to indent the desired characters in succession into the lead-backed tape, without necessarily severing the lead; and then the backing strip is peeled away to expose the layer of adhesive which pressure-bonds the indented tape to the object to be radiographed. X-rays incident on the embossed tape will cause the raised characters to show up dark on the subsequently-developed film, whilst the raised side areas will show up white. Each character will thus stand out on the developed film. (author)

  18. The structurally novel Ca2+ channel blocker Ro 40-5967, which binds to the [3H] desmethoxyverapamil receptor, is devoid of the negative inotropic effects of verapamil in normal and failing rat hearts

    International Nuclear Information System (INIS)

    Clozel, J.P.; Veniant, M.; Osterrieder, W.

    1990-01-01

    Ro 40-5967 is a structurally novel Ca 2+ channel blocker that binds to the verapamil-type receptor of cardiac membranes but that has been shown in isolated guinea-pig hearts to be about ten times less potent a negative inotropic agent than verapamil. The goals of the present study were to confirm these findings in vitro in isolated perfused rat hearts as well as in vivo in conscious rats and to compare Ro 40-5967 to verapamil. The effects of Ro 40-5967 and verapamil were tested not only in normal rats, but also in rats with heart failure induced by chronic myocardial infarction. In isolated Langendorff hearts (without heart failure), no decrease of contractility was observed with Ro 40-5967 up to complete AV block. In contrast, verapamil decreased contractility with an IC50 of 100 nM. In isolated, electrically stimulated rat papillary muscles, the IC50 values for the decrease of contractile force were 15,000 and 440 nM for Ro 40-5967 and verapamil, respectively. In vivo, Ro 40-5967 did not decrease left ventricular contractility (as assessed by changes of dP/dt max +) in rats without and with heart failure. In contrast, verapamil was markedly negative inotropic in both conditions

  19. Radiographic liver size in Pekingese dogs versus other dog breeds.

    Science.gov (United States)

    Choi, Jihye; Keh, Seoyeon; Kim, Hyunwook; Kim, Junyoung; Yoon, Junghee

    2013-01-01

    Differential diagnoses for canine liver disease are commonly based on radiographic estimates of liver size, however little has been published on breed variations. Aims of this study were to describe normal radiographic liver size in Pekingese dogs and to compare normal measurements for this breed with other dog breeds and Pekingese dogs with liver disease. Liver measurements were compared for clinically normal Pekingese (n = 61), normal non-Pekingese brachycephalic (n = 45), normal nonbrachycephalic (n = 71), and Pekingese breed dogs with liver disease (n = 22). For each dog, body weight, liver length, T11 vertebral length, thoracic depth, and thoracic width were measured on right lateral and ventrodorsal abdominal radiographs. Liver volume was calculated using a formula and ratios of liver length/T11 vertebral length and liver volume/body weight ratio were determined. Normal Pekingese dogs had a significantly smaller liver volume/body weight ratio (16.73 ± 5.67, P dogs (19.54 ± 5.03) and normal nonbrachycephalic breed dogs (18.72 ± 6.52). The liver length/T11 vertebral length ratio in normal Pekingese (4.64 ± 0.65) was significantly smaller than normal non-Pekingese brachycephalic breed dogs (5.16 ± 0.74) and normal nonbrachycephalic breed dogs (5.40 ± 0.74). Ratios of liver volume/body weight and liver length/T11 vertebral length in normal Pekingese were significantly different from Pekingese with liver diseases (P dogs have a smaller normal radiographic liver size than other breeds. We recommend using 4.64× the length of the T11 vertebra as a radiographic criterion for normal liver length in Pekingese dogs. © 2012 Veterinary Radiology & Ultrasound.

  20. Radiographic findings in pulmonary hypertension from unresolved embolism

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, W.W. III; Hoeck, B.E.; Chitwood, W.R. Jr.; Lyerly, H.K.; Sabiston, D.C. Jr.; Chen, J.T.T.

    1985-04-01

    Pulmonary artery hypertension with chronic pulmonary embolism is an uncommon entity that is potentially treatable with pulmonary embolectomy. Although the classic radiographic features have been described, several recent investigators report a significant percentage of these patients with normal chest radiographs. In a series of 22 patients, no normal radiographs were seen. Findings included cardiomegaly (86.4%) with right-sided enlargement (68.4%), right descending pulmonary artery enlargement (54.5%), azygos vein enlargement (27.3%), mosaic oligemia (68.2%), chronic volume loss (27.3%), atelectasis and/or effusion (22.7%), and pleural thickening (13.6%). Good correlation with specific areas of diminished vascularity was seen on chest radiographs compared with pulmonary angiograms.

  1. Radiographic findings in pulmonary hypertension from unresolved embolism

    International Nuclear Information System (INIS)

    Woodruff, W.W. III; Hoeck, B.E.; Chitwood, W.R. Jr.; Lyerly, H.K.; Sabiston, D.C. Jr.; Chen, J.T.T.

    1985-01-01

    Pulmonary artery hypertension with chronic pulmonary embolism is an uncommon entity that is potentially treatable with pulmonary embolectomy. Although the classic radiographic features have been described, several recent investigators report a significant percentage of these patients with normal chest radiographs. In a series of 22 patients, no normal radiographs were seen. Findings included cardiomegaly (86.4%) with right-sided enlargement (68.4%), right descending pulmonary artery enlargement (54.5%), azygos vein enlargement (27.3%), mosaic oligemia (68.2%), chronic volume loss (27.3%), atelectasis and/or effusion (22.7%), and pleural thickening (13.6%). Good correlation with specific areas of diminished vascularity was seen on chest radiographs compared with pulmonary angiograms

  2. Radiographic analysis of pasteurized autologous bone graft

    International Nuclear Information System (INIS)

    Ahmed, Adel Refaat; Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi

    2003-01-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  3. Radiographic analysis of pasteurized autologous bone graft

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Adel Refaat [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan); Department of Orthopedic Surgery, Alexandria University, Alexandria (Egypt); Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan)

    2003-08-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  4. Comparative study cephalometric-radiographic of the cephalo-facio-dental patterns in patients who presented normal occlusion and class II, division 1 malocclusions, considering variations of the FMA angle

    International Nuclear Information System (INIS)

    David, S.M.N.

    1986-01-01

    The proposal of this job was to study cephalo-facio-dental patterns comparatively in patients who presented normal occlusion and Class II, division 1 malocclusions, considering variations of the FMA angle. The sample was composed of seventy-five telerradiographies on lateral pattern, obtained from Brazilian teenagers students of the ABC area (Santo Andre, Sao Bernardo do Campo and Sao Caetano do Sul), 'whites', who presented normal occlusion and Class II, division 1 malocclusions, without previous orthodontic treatment: their parents were Brazilian. (author) [pt

  5. Digitization of conventional radiographs

    International Nuclear Information System (INIS)

    Wenz, W.; Buitrago-Tellez, C.; Blum, U.; Hauenstein, K.H.; Gufler, H.; Meyer, E.; Ruediger, K.

    1992-01-01

    The diagnostic value of a digitization system for analogue films based on a charge-coupled-device (CCD) scanner with adjustable resolution of 2.5 or 5 lp/mm was assessed. Some 110 skeletal radiographs, 50 contrast studies, including 25 of patients with Crohn's disease, and 70 abdominal plain films before and after successful lithotripsy for renal stones were digitized. Receiver operating characteristic (ROC) studies showed improved detection of cortical and trabecular defects with contrast-optimized digitized films. Edge enhancement algorithms yielded no additional information. Inflammatory lesions of Crohn's disease were detected equally well by conventional films and digitized images. A statistically significant improvement (p [de

  6. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Bevan, J.A.

    1983-01-01

    This invention relates to radiodiagnostic agents and more particularly to a composition and method for preparing a highly effective technetium-99m-based bone scanning agent. One deficiency of x-ray examination is the inability of that technique to detect skeletal metastases in their incipient stages. It has been discovered that the methanehydroxydiphosphonate bone mineral-seeking agent is unique in that it provides the dual benefits of sharp radiographic imaging and excellent lesion detection when used with technetium-99m. This agent can also be used with technetium-99m for detecting soft tissue calcification in the manner of the inorganic phosphate radiodiagnostic agents

  7. Radiographic film digitizing devices

    International Nuclear Information System (INIS)

    McFee, W.H.

    1988-01-01

    Until recently, all film digitizing devices for use with teleradiology or picture archiving and communication systems used a video camera to capture an image of the radiograph for subsequent digitization. The development of film digitizers that use a laser beam to scan the film represents a significant advancement in digital technology, resulting in improved image quality compared with video scanners. This paper discusses differences in resolution, efficiency, reliability, and the cost between these two types of devices. The results of a modified receiver operating characteristic comparison study of a video scanner and a laser scanner manufactured by the same company are also discussed

  8. Interpreting radiographs. 4. The carpus

    International Nuclear Information System (INIS)

    Burguez, P.N.

    1984-01-01

    The complexity of the carpus which has three major joints, seven or eight carpal bones and five adjacent bones, each of which articulates with one or more of the carpal elements, necessitates good quality radiographs for definitive radiographic interpretation may be extremely difficult because of the disparity between radiographic changes and obvious clinical signs and, therefore, must be discussed in the light of a thorough clinical assessment

  9. A study on the difference in the accuracy between radiographs and CT in detecting pulmonary lesions of tuberculosis

    International Nuclear Information System (INIS)

    Noumi, Fumiko; Kaneko, Takeshi; Inoue, Masako

    2010-01-01

    Classification of pulmonary tuberculosis designated by the Japanese Society for Tuberculosis is a classification of pulmonary tuberculosis on radiographs findings. We analyzed both radiographs and CT in 150 patients with lung tuberculosis at the diagnosis based on the society classification. In 52 patients, the classification by radiographs was not consistent with that by CT. Generally, radiographs missed small and faint opacities in the lung. There were cases which showed tuberculous opacities in CT, diagnosed as normal by Radiographs. It is concluded that the diagnosis of the pulmonary tuberculosis by chest radiographs may lead to underdiagnosis and underestimation of its severity. Hence, chest CT is very useful for making an accurate diagnosis. (author)

  10. Heart Health - Brave Heart

    Science.gov (United States)

    ... Bar Home Current Issue Past Issues Cover Story Heart Health Brave Heart Past Issues / Winter 2009 Table of Contents For ... you can have a good life after a heart attack." Lifestyle Changes Surviving—and thriving—after such ...

  11. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  12. The radiographic features of familial expansile osteolysis

    International Nuclear Information System (INIS)

    Crone, M.D.; Wallace, R.G.H.

    1990-01-01

    The radiographic features of a unique autosomal dominant bone dysplasia are presented. The features are classified as generalised and/or focal. Generalised features are either altered trabecular pattern or modelling abnormalities. Focal features comprise lytic areas which progressively enlarge, producing expansion of the bone and eventual disintegration due to fibrous and finally fatty replacement of the normal medulla. Almost 90% of these lesions occur in the appendicular skeleton. Clinically, hearing loss is the earliest manifestation of the disease, presenting sometimes as early as 4 years of age. Apical and cervical resorption of teeth is extremely common, resulting in premature loss of teeth. Radiologically, the differential diagnosis refers to Paget's disease, polyostotic fibrous dysplasia, and osteofibrous dysplasia. The progressive destruction of the bone is similar to massive osteolysis (Gorham's disease). The radiographic features in combination with the histopathology render the condition unique. (orig.)

  13. Radiographer interpretation of trauma radiographs: Issues for radiography education providers

    International Nuclear Information System (INIS)

    Hardy, Maryann; Snaith, Beverly

    2009-01-01

    Background: The role of radiographers with respect to image interpretation within clinical practice is well recognised. It is the expectation of the professional, regulatory and academic bodies that upon qualification, radiographers will possess image interpretation skills. Additionally, The College of Radiographers has asserted that its aspiration is for all radiographers to be able to provide an immediate written interpretation on skeletal trauma radiographs by 2010. This paper explores the readiness of radiography education programmes in the UK to deliver this expectation. Method: A postal questionnaire was distributed to 25 Higher Education Institutions in the UK (including Northern Ireland) that provided pre-registration radiography education as identified from the Society and College of Radiographers register. Information was sought relating to the type of image interpretation education delivered at pre- and post-registration levels; the anatomical range of image interpretation education; and education delivery styles. Results: A total of 19 responses (n = 19/25; 76.0%) were received. Image interpretation education was included as part of all radiographer pre-registration programmes and offered at post-registration level at 12 academic centres (n = 12/19; 63.2%). The anatomical areas and educational delivery methods varied across institutions. Conclusion: Radiography education providers have embraced the need for image interpretation education within both pre- and post-registration radiography programmes. As a result, UK education programmes are able to meet the 2010 College of Radiographers aspiration.

  14. Effect of (+)-amphetamine on the retention of 3H-catecholamines in slices of normal and reserpinized rat brain and heart

    International Nuclear Information System (INIS)

    Ross, S.B.; Renyi, A.L.

    1978-01-01

    The effect of reserpine on the inhibition by (+)-amphetamine and cocaine of the accumulation of 3 H-dopamine (DA) in striatal slices and 3 H-noradrenaline (NA) in slices of cerebral occipital cortex and heart atrium of rats and the release of the 3 H-amines from these tissues were examined. Reserpine (5 mg/kg intraperitoneally) was injected 18 hours before the experiments. It was found that reserpine markedly enhanced the in vitro potency of amphetamine in the striatum and heart but only slightly in the cortex. After administration in vivo (+)-amphetamine was about 10 times more potent in reducing the amine accumulation in the cortex as in the striatum. Reserpine enhanced the effect in both regions. The inhibitory potency of cocaine in vitro was unchanged by reserpine in the striatum but was reduced in the cortex and heart. Reserpine did not change the inhibitory potency of desipramine in the cortex and heart. The release of the 3 H-amines by (+)-amphetamine was enhanced by reserpine in the striatum and heart but the small release produced in the cortex was not increased. The release produced by cocaine was similarly enhanced by reserpine but cocaine was much less active than (+)-amphetamine. The results indicate that (+)-amphetamine and cocaine inhibit the amine accumulation by different mechanisms. (author)

  15. Odontogenic keratocyst radiographic features

    International Nuclear Information System (INIS)

    Nartey, N. O.; Saini, T.

    1990-01-01

    The clinical features often patients with odontogenic keratocysts were studied. One patient had Gorlin-GoJtz syndrome. A total of fourteen radiolucent lesions were observed on radiographic examination. All the fourteen lesions were diagnosed as odontogenic keratocyst after histopathclogical examination of biopsied tissue from the patients. The age at diagnosis ranged from 25-72 years with a mean age of 37.6 years. The male : female ratio was 2.3:1. Thirteen of these lesions occurred in the mandible, nine involved the mandibular third molar region. Involvement of the ramus of the mandible produced a sausage-shaped radiolucency. Cystic lesions which have been present for long periods of time showed scalloped margins, due to the regional resorption of the surrounding bone. The bony ledges present on the cortical bones simulated multilocular appearance in such cases. It was also observed that the lesions in older individuals perforated the cortical plates rather than eliciting a periostally induced bony expansion. (author)

  16. A radiographic examination system

    International Nuclear Information System (INIS)

    Cable, A.P.; Cable, W.S.

    1983-01-01

    A system for performing radiographic examination, particularly of large items such as international container units is disclosed. The system is formed as an installation comprising housings for respective linear accelerators transmitting a beam of radiation across the path of a conveyor along which the units can be displaced continuously or incrementally. On either end of the installation are container handling areas including roller conveyors with drag chains and transverse manipulators, and the whole installation is secured within automatically operated doors which seal the high energy region when a container on the conveyor is being subjected to examination. The radiation transmitted through a container is detected in a detector system incorporating a fluoroscopic screen light output from which is detected in a camera system such as a television camera, and transmitted as coded pulsed signals by a coding transfer unit to display screens where an image of the transmitted information can be displayed and/or recorded for further use. (author)

  17. Radiographic contrast media

    International Nuclear Information System (INIS)

    Golman, K.; Holtz, E.; Almen, T.

    1987-01-01

    Contrast media are used in diagnostic radiology to enhance the X-ray attenuation between a body structure of interest and the surrounding tissue. A detail becomes perceptible on a roentgenogram only when its contrast exceeds a minimum value in relation to the background. Small areas of interest must have higher contrast than the background. The contrast effect depends on concentration of the contrast media with the body. A high contrast media concentration difference thus gives rise to more morphological details in the radiographs. Contrast media can be divided into negative contrast media such as air and gas which attenuate X-rays less than the body tissues, and positive contrast materials which attenuate X-rays more than the body tissues. The positive contrast media all contain either iodine (atomic number 53) or barium (atomic number 56) and can be divided into water-insoluble and water-soluble contrast media

  18. Echocardiographic and radiographic findings in a cohort of healthy adult green iguanas (Iguana iguana).

    Science.gov (United States)

    Gustavsen, Kate A; Saunders, Ashley B; Young, Benjamin D; Winter, Randolph L; Hoppes, Sharman M

    2014-09-01

    To describe characteristics of echocardiography and cranial coelomic radiography in a cohort of iguanas. Twenty apparently healthy adult green iguanas (Iguana iguana) from a reptile sanctuary. Physical examination, radiography, two-dimensional and color Doppler echocardiography were performed to assess cardiac structures and function, and any related normal or abnormal findings were recorded. Echocardiographic examination was possible without sedation and allowed visualization of the great vessels, atria, and ventricle. Some structures could not be evaluated in a minority of the iguanas due to individual differences in bony conformation and imaging quality. Suspected abnormal echocardiographic findings in 3 iguanas included pericardial effusion (n = 1) and enlarged caudal vena cava and/or sinus venosus (n = 2). Objective measurements were repeatable as assessed by within-subject coefficient of variation, and reliable as assessed by intra-observer intraclass correlation coefficient. Left atrial and ventricular measurements were significantly correlated with body weight. Valve regurgitation was common, with atrioventricular valve regurgitation present in 53% (9/17) and aortic or pulmonic valve regurgitation in 71% (12/17) of otherwise normal iguanas. A heart murmur was not appreciated during examination of any of the iguanas. Heart size cannot be measured radiographically due to superimposition and silhouetting of other coelomic structures. Echocardiographic or radiographic findings consistent with mineralization of the great vessels were present in 76% of iguanas (13/17). Echocardiography in iguanas is well tolerated without sedation and allowed both subjective evaluation and structural measurements. Valve regurgitation and great vessel mineralization were commonly observed in this cohort of apparently healthy adult iguanas. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Radiographic enhancement and analysis system

    International Nuclear Information System (INIS)

    Schlosser, M.S.

    1981-01-01

    Radiographic image enhancement and analysis techniques are discussed as they apply to nondestructive inspection. A system is described which has been developed to enhance and quantitatively evaluate radiographic images using digital computer techniques. Some examples of typical applications are also presented as an introduction to this new inspection technique. (author)

  20. Radiographic appearance of the navicular bone in sound horses

    International Nuclear Information System (INIS)

    Kaser-Hotz, B.; Ueltschi, G.

    1992-01-01

    Radiographs of the navicular bone in 523 sound horses were reviewed. Detailed evaluation criteria were used. The incidence of radiographic changes and variations in normal horses were recorded. Results were tested for right-left limb difference and for age relationship. Variation in shape and bone structure was commonly seen in the navicular bone. Radiographic changes with an incidence of less than 2% included flexor cortex defects and calcification on the flexor surface. Fragments at the distal navicular bone border, calcification in the impar ligament and enthesiophytes at the proximal border were radiographic findings with an incidence of 2% to 10%. Abnormal canals at the distal border were found in 11% horses. Elongation of the lateral proximal extremity was commonly found. The mean width of the flexor cortex was 3.6 mm

  1. Radiographic and scintigraphic evaluation of total knee arthroplasty

    International Nuclear Information System (INIS)

    Schneider, R.; Soudry, M.

    1986-01-01

    Various radiographic and scintigraphic methods are used to supplement clinical findings in the evaluation of total knee arthroplasty and its complications. Serial roentgenograms offer reliable information for diagnosing mechanical loosening. Wide and extensive radiolucency at the cement-bone interface and shift in position and alignment of prosthetic components can be seen in almost all cases by the time revision is necessary. Radiographic abnormalities are usually not present in acute infection, but are often present in chronic infection. Bone scanning has a high sensitivity for diagnosis of infection or loosening, but is nonspecific because increased uptake is often present around asymptomatic total knee arthroplasties with normal radiographs. Differential bone and Gallium scanning and scanning with Indium 111-labeled leukocytes have a greater specificity for diagnosis of infection than does bone or Gallium scanning alone. Routine radiographic and scintigraphic studies have shown a high incidence of deep vein thrombosis in the calf after total knee arthroplasty. Clinically significant pulmonary embolization is infrequent

  2. Radiographic evaluation of caudal vena cava size in dogs

    International Nuclear Information System (INIS)

    Lehmkuhl, L.B.; Bonagura, J.D.; Biller, D.S.; Hartman, W.M.

    1997-01-01

    Dilation of the caudal vena cava (CVC) on lateral thoracic radiographs is often interpreted as suggestive of right-sided congestive heart failure, To quantitate the clinical utility of evaluating CVC size as an indicator of right-sided heart disease, we compared the ratio of the diameter of the CVC as measured on a left lateral thoracic radiograph to the descending aorta (Ao), length of the thoracic vertebra above the tracheal bifurcation (VL), and width of the right fourth rib (R4) in 35 dogs with right heart disease and 35 control dogs, Each CVC ratio(CVC/Ao, CVC/VL, CVC/R4) was statistically larger in dogs with right heart disease, Response operating characteristic curves and likelihood ratios were used to determine ratios helpful in identifying dogs with right heart disease. A CVC/Ao > 1.50, CVC/VL > 1.30, or CVC/R4 > 3.50 are strongly suggestive of a right-sided heart abnormality in a patient

  3. Interpretation and digestion of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Radiography digestion is final test for the radiography to make sure that radiograph produced will inspect their quality of the image before its interpreted. This level is critical level where if there is a mistake, all of the radiography work done before will be unaccepted. So as mention earlier, it can waste time, cost and more worst it can make the production must shut down. So, this step, level two radiographers or interpreter must evaluate the radiograph carefully. For this purpose, digestion room and densitometer must used. Of course all the procedure must follow the specification that mentioned in document. There are several needs must fill before we can say the radiograph is corrected or not like the location of penetrameter, number of penetrameter that showed, the degree of density of film, and usually there is no problem in this step and the radiograph can go to interpretation and evaluation step as will mentioned in next chapter.

  4. Chesneys' radiographic imaging. 5. ed.

    International Nuclear Information System (INIS)

    Ball, J.; Price, T.

    1989-01-01

    This new edition of Chesney and Chesney: Radiographic Imaging has been completely written by two new authors. The book reflects the change in emphasis in radiology from photographic processes towards electronic imaging methods. There is new material on image intensifiers and television imaging, digital imaging and digital subtractions. Analyses of the various characteristics of, and defects in, images on radiographs, xeroradiographs and the television screen are included. The methods, equipment and materials used to record the cathode ray tube image are described and there is new material on the principles of alternative diagnostic imaging techniques such as ultrasound, computed tomography and radionuclide imaging which provide cathode ray tube images. The book is primarily for student radiographers studying for the Diploma of the College of Radiographers, but radiographers studying for postdiplomate qualifications such as the Higher Diploma (HDCR) will also find the book helpful. (author)

  5. Heart MRI

    Science.gov (United States)

    Magnetic resonance imaging - cardiac; Magnetic resonance imaging - heart; Nuclear magnetic resonance - cardiac; NMR - cardiac; MRI of the heart; Cardiomyopathy - MRI; Heart failure - MRI; Congenital heart disease - MRI

  6. Is Heart Period Variability Associated with the Administration of Lifesaving Interventions in Individual Prehospital Trauma Patients with Normal Standard Vital Signs?

    Science.gov (United States)

    2010-08-01

    heart period variability as an indicator of mortality in intensive care unit patients many hours before death. Similarly, re- cent studies using data...the Department of Health and Kinesiology (CAR), The University of Texas at San Antonio, San An- tonio, TX; U.S. Army Institute of Surgical Research (CAR

  7. Clinical evaluation of ischemic heart diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Kamei, Fumio [Sendai Railway Hospital (Japan)

    1983-09-01

    Attempt were made to detect the existence of myocardial ischemia by means of both radiographic and scintigraphic techniques. Firstly, a new polygraph was especially designed for selecting the arbitrary phases in a cardiac cycle at which the corresponding radiogram should be synchronously obtained. A comparative investigation on the difference between end-systolic and-diastolic cardiac transverse diameters revealed a remarkable difference of 3.6% in normal subjects and 0.6% in patients with ischemic heart disease. These data indicating the difference of overall heart size was reflected in local dyskinesis documentation of recently developed techniques. For daily clinical purposes, radiography of the chest based on synchronously selected phases would contribute to accurate diagnosis and treatment of heart disease. Secondly, scintigraphic display using intravenously injected thallium-201 was clinically applied. For detection of ischemia, comparative study was performed of initial image relative to selective coronary cineangiography and stress scintigraphy. The former indicated a good correlation of 90%, whereas the latter served to enhance sensitivity. Sequential images (initial and delayed) facilitated the distinction of normal, necrotic, and ischemic areas. Scintigram was used for objective evaluation of coronary dilator (dilazep), either at immediate or follow-up stage. In the same way, it was also possible to indicate the effectiveness of sublingually given nitroglycerin by myocardial scintigram, where by significant increase of uptake was observed 20 minutes after administration. Rehabilitation after acute heart disease was discussed, especially on the peripheral effect. Ratio of the thigh muscle to myocardium shown in this study was useful for objective evaluation. Another preliminary study is to separate normal coronary arteries from myocardial necrosis.

  8. Clinical evaluation of ischemic heart diagnosis

    International Nuclear Information System (INIS)

    Kamei, Fumio

    1983-01-01

    Attempt were made to detect the existence of myocardial ischemia by means of both radiographic and scintigraphic techniques. Firstly, a new polygraph was especially designed for selecting the arbitrary phases in a cardiac cycle at which the corresponding radiogram should be synchronously obtained. A comparative investigation on the difference between end-systolic and-diastolic cardiac transverse diameters revealed a remarkable difference of 3.6% in normal subjects and 0.6% in patients with ischemic heart disease. These data indicating the difference of overall heart size was reflected in local dyskinesis documentation of recently developed techniques. For daily clinical purposes, radiography of the chest based on synchronously selected phases would contribute to accurate diagnosis and treatment of heart disease. Secondly, scintigraphic display using intravenously injected thallium-201 was clinically applied. For detection of ischemia, comparative study was performed of initial image relative to selective coronary cineangiography and stress scintigraphy. The former indicated a good correlation of 90%, whereas the latter served to enhnace sensitivity. Sequential images (initial and delayed) facilitated the distinction of normal, necrotic, and ischemic areas. Scintigram was used for objective evaluation of coronary dilator (dilazep), either at immediate or follow-up stage. In the same way, it was also possible to indicate the effectiveness of sublingually given nitroglycerin by myocardial scintigram, where by significant increase of uptake was observed 20 minutes after administration. Rehabilitation after acute heart disease was discussed, especially on the peripheral effect. Ratio of the thigh muscle to myocardium shown in this study was useful fer objective evaluation. Another preliminary study is to separate normal coronary arteries from myocardial necrosis. (J.P.N.)

  9. The Risk of Heart Failure and Cardiometabolic Complications in Obesity May Be Masked by an Apparent Healthy Status of Normal Blood Glucose

    Directory of Open Access Journals (Sweden)

    Shuchita Tiwari

    2013-01-01

    Full Text Available Although many obese individuals are normoglycemic and asymptomatic of cardiometabolic complications, this apparent healthy state may be a misnomer. Since heart failure is a major cause of mortality in obesity, we investigated the effects of heme-oxygenase (HO on heart failure and cardiometabolic complications in obese normoglycemic Zucker-fatty rats (ZFs. Treatment with the HO-inducer, hemin, reduced markers of heart failure, such as osteopontin and osteoprotegerin, abated left-ventricular (LV hypertrophy/fibrosis, extracellular matrix/profibrotic proteins including collagen IV, fibronectin, TGF-β1, and reduced cardiac lesions. Furthermore, hemin suppressed inflammation by abating macrophage chemoattractant protein-1, macrophage-inflammatory protein-1 alpha, TNF-α, IL-6, and IL-1β but enhanced adiponectin, atrial-natriuretic peptide (ANP, HO activity, insulin sensitivity, and glucose metabolism. Correspondingly, hemin improved several hemodynamic/echocardiographic parameters including LV-diastolic wall thickness, LV-systolic wall thickness, mean-arterial pressure, arterial-systolic pressure, arterial-diastolic pressure, LV-developed pressure, +dP/dt, and cardiac output. Contrarily, the HO-inhibitor, stannous mesoporphyrin nullified the hemin effect, exacerbating inflammatory/oxidative insults and aggravated insulin resistance (HOMA-index. We conclude that perturbations in insulin signaling and cardiac function may be forerunners to overt hyperglycemia and heart failure in obesity. Importantly, hemin improves cardiac function by suppressing markers of heart failure, LV hypertrophy, cardiac lesions, extracellular matrix/profibrotic proteins, and inflammatory/oxidative mediators, while concomitantly enhancing the HO-adiponectin-ANP axis.

  10. Radiographic evaluation of coxofemoral joint laxity in dogs part I: New stress-radiographic positioning techniques

    International Nuclear Information System (INIS)

    Phiwipha Kamonrat; Duangdaun Kaenkangploo

    2002-01-01

    Two new stress-radiographic positioning techniques, namely 60 deg and 90 deg stress techniques, were introduced for quantifying hip joint laxity in dogs. The comparative characteristics and efficiency of these new techniques with angled hindlimbs were evaluated relative to the standard hip-extended radiographic technique. Forty, healthy, mongrel dogs with normal hip joint conformation were anesthetized and placed in dorsal recumbency before 3 radiograhps of the standard, 60 deg , and 90 deg stress techniques were taken. For the 60 deg stress technique, hindlimbs were extended in parallel to each other at 60 deg angled to the table top and stifles were slightly rotated inward, femoral heads were manually pushed in a craniodorsal direction during exposure. For the 90 deg stress technique, femurs were positioned perpendicular to the table top, stifles were 90 deg flexed and adducted and femoral heads were manually pushed in a craniodorsal direction during exposure. The subluxation index (SI) and dorsolateral subluxation score (DLS score) were calculated from 3 radiographic views for both hip joints to quantitate the relative degree of joint laxity. Results of the study indicated that the 60 deg (SI = 0.20+-0.045, DLS score = 62.5+-7.96 percent) and 90 deg (SI = 0.23+-0.044, DLS score = 61.2+-9.47 percent) stress-radiographs yielded significantly (p0.001) higher degree of hip joint laxity than the standard technique (SI)

  11. The interpretation of plain film radiographs in infants and children with cardiac and vascular malformations. Pt. 1

    International Nuclear Information System (INIS)

    Rautenburg, H.W.

    1987-01-01

    Chest survey radiographs frequently suffice for a differentiation of congenital defects of the heart and the vessels. Finally, angiocardiography will allow exact differentiation of the pathological findings in complex angiocardiopathies. (orig.) [de

  12. Chest radiographic manifestations of scrub typhus.

    Science.gov (United States)

    Abhilash, Kpp; Mannam, P R; Rajendran, K; John, R A; Ramasami, P

    2016-01-01

    Respiratory system involvement in scrub typhus is seen in 20-72% of patients. In endemic areas, good understanding and familiarity with the various radiologic findings of scrub typhus are essential in identifying pulmonary complications. Patients admitted to a tertiary care center with scrub typhus between October 2012 and September 2013 and had a chest X ray done were included in the analysis. Details and radiographic findings were noted and factors associated with abnormal X-rays were analyzed. The study cohort contained 398 patients. Common presenting complaints included fever (100%), generalized myalgia (83%), headache (65%), dyspnea (54%), cough (24.3%), and altered sensorium (14%). Almost half of the patients (49.4%) had normal chest radiographs. Common radiological pulmonary abnormalities included pleural effusion (14.6%), acute respiratory distress syndrome (14%), airspace opacity (10.5%), reticulonodular opacities (10.3%), peribronchial thickening (5.8%), and pulmonary edema (2%). Cardiomegaly was noted in 3.5% of patients. Breathlessness, presence of an eschar, platelet counts of 2 mg/dL had the highest odds of having an abnormal chest radiograph. Patients with an abnormal chest X-ray had a higher requirement of noninvasive ventilation (odds ratio [OR]: 13.98; 95% confidence interval CI: 5.89-33.16), invasive ventilation (OR: 18.07; 95% CI: 6.42-50.88), inotropes (OR: 8.76; 95% CI: 4.35-17.62), higher involvement of other organ systems, longer duration of hospital stay (3.18 ± 3 vs. 7.27 ± 5.58 days; Pscrub typhus have abnormal chest radiographs. Chest radiography should be included as part of basic evaluation at presentation in patients with scrub typhus, especially in those with breathlessness, eschar, jaundice, and severe thrombocytopenia.

  13. Radiographic scanner apparatus

    International Nuclear Information System (INIS)

    Wake, R.H.

    1980-01-01

    The preferred embodiment of this invention includes a hardware system, or processing means, which operates faster than software. Moreover the computer needed is less expensive and smaller. Radiographic scanner apparatus is described for measuring the intensity of radiation after passage through a planar region and for reconstructing a representation of the attenuation of radiation by the medium. There is a source which can be rotated, and detectors, the output from which forms a data line. The detectors are disposed opposite the planar region from the source to produce a succession of data lines corresponding to the succession of angular orientations of the source. There is a convolver means for convolving each of these data lines, with a filter function, and a means of processing the convolved data lines to create the representation of the radiation attenuation in the planar region. There is also apparatus to generate a succession of data lines indicating radiation attenuation along a determinable path with convolver means. (U.K.)

  14. Radiographic changes in rhesus macaques affected by scurvy

    International Nuclear Information System (INIS)

    Morgan, J.P.; Eisele, P.H.

    1992-01-01

    Spontaneous vitamin C deficiency, or scurvy, was recognized in juvenile rhesus monkeys maintained in a research center as a result of being fed a commercial diet for 2 to 3 months with low levels of vitamin C. Most severely affected animals (13) were radiographed repeatedly up to day 300 following detection of the disease. Early radiographic changes consisted of widened, lucent metaphyses with lateral flaring and radiopaque metaphyseal lines at the junction of the metaphyses and physes. Physeal slippage was noted commonly. Following institution of vitamin C therapy, calcification of subperiosteal hemorrhage occurred in the metaphyseal regions. Metaphyses and physes returned to normal radiographic appearance within 15 to 30 days. Initially, the subperiosteal hemorrhage progressed and a longer time was required for solution of the calcified hematomas. The macaques improved clinically and were released from the hospital when fractures were stable at 4-5 weeks after admission. Of the 13 macaques studied, all but one returned as normal members of the colony

  15. The radiographic image: A cultural artefact?

    International Nuclear Information System (INIS)

    Strudwick, Ruth M.

    2014-01-01

    This article looks at the role of the radiographic images produced by diagnostic radiographers. An ethnographic study of the workplace culture in one diagnostic imaging department was undertaken using participant observation for four months and semi-structured interviews with ten key informants. One of the key themes; that of the radiographic image as a cultural artefact, is explored in this article. The radiographic image is a cultural artefact which radiographers are protective of and take ownership of. Radiographers are conscious of the quality of their images and the images are an important aspect of their work. Radiographers take criticism of their images personally. The radiographic image is a record of the interaction that occurs between the radiographer and the patient. The way in which radiographic images are viewed, used and judged is an important aspect of the role of diagnostic radiographer

  16. The sharp edge: a frequent radiographic sign in neonatal pneumothorax

    International Nuclear Information System (INIS)

    Oestreich, A.E.

    1987-01-01

    The sharp edge sign, an unusually sharply defined silhouette of the heart and/or hemidiaphragm on frontal radiographs of the supine neonate, has been valuable in the initial recognition of pneumothorax. In a prospective study of 50 neonatal pneumothoraces, a sharp edge sign was present on the initial pneumothorax film 49 times. In seven of these, only the hemidiaphragm showed a sharp edge, while the heart margin was superimposed on the vertebral column. Greater awareness of the sharp edge sign would promote earlier recognition of neonatal pneumothorax. 6 refs.; 3 figs

  17. Radiographic film cassette unloading apparatus

    International Nuclear Information System (INIS)

    Stievenart, E.F.; Plessers, H.S.; Neujens, G.J.

    1980-01-01

    Apparatus for unloading cassettes, containing exposed radiographic films, has means for unfastening the cassettes, an inclined pathway for gravity feeding and rotating feed members (rollers or belts) to propel the films into the processor. (UK)

  18. Heart murmurs

    Science.gov (United States)

    Chest sounds - murmurs; Heart sounds - abnormal; Murmur - innocent; Innocent murmur; Systolic heart murmur; Diastolic heart murmur ... The heart has 4 chambers: Two upper chambers (atria) Two lower chambers (ventricles) The heart has valves that close ...

  19. Method for taking X radiographs

    International Nuclear Information System (INIS)

    Orth, G.

    1983-01-01

    The method is aimed at obtaining X radiographs of any human organ with the aid of an X-ray-shadowless radiation detector of a dose measuring device, which is arranged between patient and imaging system, and of a controlling microprocessor system, so that the image-forming parameters are automatically adjusted to the specific properties of the patient. This procedure minimices the efforts in preparing the radiograph and the radiation exposure of the patient

  20. Film holder for radiographing tubing

    International Nuclear Information System (INIS)

    Davis, E.V.; Foster, B.E.

    1976-01-01

    A film cassette is described which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro

  1. The radiographic manifestations of hypochondroplasia

    International Nuclear Information System (INIS)

    Heselson, N.G.; Cremin, B.J.; Beighton, P.

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations. (author)

  2. Film holder for radiographing tubing

    Science.gov (United States)

    Davis, Earl V.; Foster, Billy E.

    1976-01-01

    A film cassette is provided which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro.

  3. Radiographically ossified ganglion cyst of finger in a swimmer

    Energy Technology Data Exchange (ETDEWEB)

    Tehranzadeh, J.; Anavim, A. [Department of Radiological Sciences, University of California, Orange (United States); Lin, F. [Department of Pathology, University of California, Irvine Medical Center, Orange (Canada)

    1998-12-01

    Ganglion cysts are fibrous-walled cystic lesions closely associated with joint or tendon sheaths and contain gelatinous mucinous fluid. The radiographic appearance is usually normal. Calcification or ossification in these cysts is extremely unusual. We report on an unusual appearing ganglion cyst of the little finger in a swimmer with ossification resembling myositis ossificans. (orig.) With 3 figs., 8 refs.

  4. Radiographic signs of isolated splenic torsion in dogs: eight cases (1980-1987)

    International Nuclear Information System (INIS)

    Stickle, R.L.

    1989-01-01

    Abdominal radiographs of 8 dogs with confirmed isolated splenic torsions were evaluated retrospectively. Radiographic signs included suboptimal abdominal detail, displacement of other abdominal organs, loss of visualization of the body of the spleen in its normal position (in the left cranial portion of the abdomen) on the ventrodorsal radiographic view, identification of the spleen in an abnormal location or shape, splenomegaly, and splenic gas. When the spleen location and shape could be identified as abnormal (3 dogs), the spleen appeared folded into a C shape in the central portion of the abdomen on the lateral radiographic view

  5. Radiographic anatomy of the thoraco-abdominal cavity of the ostrich (Struthio camelus

    Directory of Open Access Journals (Sweden)

    W.M. Wagner

    2001-07-01

    Full Text Available This study provides a reference for the radiographic anatomy of the thoraco-abdominal cavity of female ostriches as a representative of ratites. One ostrich cadaver, 2 adult and 2 growing ostriches were used. Right lateral radiographs produced by a 6-frame technique and 2 dorsoventral radiographs produced by an adapted 3-frame technique were selected and schematic illustrations of these were labelled to illustrate normal radiographic anatomy. Differences from other avian species and unique features of the ostrich are briefly discussed.

  6. Digital image processing of mandibular trabeculae on radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ogino, Toshi

    1987-06-01

    The present study was aimed to reveal the texture patterns of the radiographs of the mandibular trabeculae by digital image processing. The 32 cases of normal subjects and the 13 cases of patients with mandibular diseases of ameloblastoma, primordial cysts, squamous cell carcinoma and odontoma were analyzed by their intra-oral radiographs in the right premolar regions. The radiograms were digitized by the use of a drum scanner densitometry method. The input radiographic images were processed by a histogram equalization method. The result are as follows : First, the histogram equalization method enhances the image contrast of the textures. Second, the output images of the textures for normal mandible-trabeculae radiograms are of network pattern in nature. Third, the output images for the patients are characterized by the non-network pattern and replaced by the patterns of the fabric texture, intertwined plants (karakusa-pattern), scattered small masses and amorphous texture. Thus, these results indicates that the present digital image system is expected to be useful for revealing the texture patterns of the radiographs and in the future for the texture analysis of the clinical radiographs to obtain quantitative diagnostic findings.

  7. Cardiopulmonary Exercise Testing in Fontan Patients With and Without Isomerism (Heterotaxy) as Compared to Patients With Primary Ciliary Dyskinesia and Subjects With Structurally Normal Hearts

    DEFF Research Database (Denmark)

    Loomba, Rohit S; Danduran, Michael; Nielsen, Kim G

    2017-01-01

    with and without isomerism. We have now compared these finding with those from patients with primary ciliary dyskinesia, as many patients with isomerism have ciliary dyskinesia. We identified patients having the Fontan circulation with and without isomerism who had undergone cardiopulmonary exercise testing......, comparing the findings from healthy individuals undergoing exercise, and a comparable number of individuals with primary ciliary dyskinesia but no congenital heart disease. We were able to include a total of 68 patients in our study, with 17 in each of the four groups. Cardiopulmonary exercise testing...

  8. Radiographic pathology for technologists

    International Nuclear Information System (INIS)

    Mace, J.D.; Kowalczyk, N.

    1988-01-01

    This book explains the fundamentals of disease mechanisms and relates this to the practice of radiologic science. Each chapter begins with a discussion of normal anatomy and physiology, then covers pathology and demonstrates how the pathology appears on film. Imaging modalities such as computed tomography, MRI, and ultrasound are also discussed. Clinical case studies are included

  9. Thoracic and heart biometrics of non-anesthetized agouti (Dasyprocta primnolopha Wagler, 1831 measured on radiographic images Biometria torácica e cardíaca de cutias não anestesiadas (Dasyprocta primnolopha Wagler, 1831 mensuradas em imagens radiográficas

    Directory of Open Access Journals (Sweden)

    Anaemilia das N. Diniz

    2013-03-01

    Full Text Available The agouti is a species intensively hunted throughout the Amazon and the semi-arid regions of northeastern Brazil. Considering the current trend in conservation management of wild species, the aim of this study was to determine the morphometric reference to the heart of agouti raised in captivity, based on thoracic and cardiac measurements in these animals. Thirty adult agoutis, 1 to 3 years of age, without clinical signs of cardiac disease were selected. The animals were physically restrained and radiographies in laterolateral (LL and ventrodorsal (VD recumbence were produced. The following measures were taken: the apicobasilar length of the heart (at the most cranial height of the Carina region to the heart apex (AB, maximum width of the heart perpendicular to AB (CD, heart inclination angle (AIC, trachea inclination angle (AIT, distance from the right heart wall (DPTd, distance from the left heart wall (DPTe and vertical depth of the thorax, and the ventral face of the vertebral column to the dorsal border of the sternum at the level of the trachea bifurcation (H. The ratios between AB/CD, AB/H and CD/H were also analyzed. To calculate the vertebral heart scale (VHS, the AB and CD measurements were laid over the thoracic vertebra starting at T4. Radiographic evaluation showed values consistent with those reported in small animals and some wild and exotic species. The main biometric values in the chest cavity and heart of agouti are arranged as follows: (1 The ratios between AB/H ratio and CD/H were not sensitive for identifying heart increases (p>0.05, while the ratio AB/CD was more sensitive in this identification (pA cutia é uma espécie intensamente caçada em toda a Amazônia e nas regiões semi-áridas do Nordeste do Brasil. Considerando a tendência atual em gestão de conservação das espécies selvagens, o objetivo deste estudo foi determinar referências morfométricas para o coração de cutia criadas em cativeiro, com base em

  10. Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts

    International Nuclear Information System (INIS)

    Hambye, Anne-Sophie; Vervaet, Ann; Dobbeleir, Andre

    2004-01-01

    Several software packages are commercially available for quantification of left ventricular ejection fraction (LVEF) and volumes from myocardial gated single-photon emission computed tomography (SPECT), all of which display a high reproducibility. However, their accuracy has been questioned in patients with a small heart. This study aimed to evaluate the performances of different software and the influence of modifications in acquisition or reconstruction parameters on LVEF and volume measurements, depending on the heart size. In 31 patients referred for gated SPECT, 64 2 and 128 2 matrix acquisitions were consecutively obtained. After reconstruction by filtered back-projection (Butterworth, 0.4, 0.5 or 0.6 cycles/cm cut-off, order 6), LVEF and volumes were computed with different software [three versions of Quantitative Gated SPECT (QGS), the Emory Cardiac Toolbox (ECT) and the Stanford University (SU-Segami) Medical School algorithm] and processing workstations. Depending upon their end-systolic volume (ESV), patients were classified into two groups: group I (ESV>30 ml, n=14) and group II (ESV 2 to 128 2 were associated with significantly larger volumes as well as lower LVEF values. Increasing the filter cut-off frequency had the same effect. With SU-Segami, a larger matrix was associated with larger end-diastolic volumes and smaller ESVs, resulting in a highly significant increase in LVEF. Increasing the filter sharpness, on the other hand, had no influence on LVEF though the measured volumes were significantly larger. (orig.)

  11. Radiographic examination of the equine head

    International Nuclear Information System (INIS)

    Park, R.D.

    1993-01-01

    Radiographic examinations of the equine head can be performed with portable x-ray machines. The views comprising the examination depend on the area of the head being examined. With a knowledge of radiographic anatomy and radiographic signs of disease, valuable diagnostic information can be obtained from the radiographic examination. In addition, the radiographic information can also be used to develop a prognosis and determine the most appropriate therapy

  12. Radiographic testing at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Bossi, R.H.

    1982-01-01

    Radiographic testing is a nondestructive inspection technique which uses penetrating radiation. The Nondestructive Evaluation (NDE) Section at Lawrence Livermore National Laboratory has a broad spectrum of equipment and techniques for radiographic testing. These resources include low-energy vacuum systems, low- and mid-energy cabinet and cell radiographic systems, high-energy linear accelerators, portable x-ray machines and radioisotopes for radiographic inspections. For diagnostic testing the NDE Section also has real-time and flash radiographic equipment

  13. Reproductive health of male radiographers

    International Nuclear Information System (INIS)

    Shakhatreh, Farouk M.

    2001-01-01

    To compare certain reproductive health problems reported in 2 groups of males, one of which was exposed to x-ray radiation (radiographers) and the other group that was not exposed to x-ray radiation. The reproductive health problems were miscarriage, congenital anomalies, still births and infertility. Two groups of men were selected (90 in each group). The first group consisted of radiographers and the other groups consisted of men not exposed to x-ray radiation. The 2 groups were matched for age and source. Relative risk, attributable risk percentage and level of significance were calculated. Incidence rate of reproductive health problems was increasing with the increase in duration of exposure to x-ray radiation ranging between 17% (for those exposed for 1-5 years) to 91% (for those exposed for more than 15 years). There were significant associations between exposure to radiation and miscarriage (relative risk = 1.67, attributable risk percentage = 40%), congenital anomalies (relative risk = 10, attributable risk percentage 90%), still birth (relative risk = 7, attributable risk percentage = 86%), and infertility (relative risk = 4.5, attributable risk = 78%). The incidence rates of reproductive health problems reported by male radiographers were significantly higher than that reported by the non exposed group and higher than the incidence rates reported in community-based studies in Jordan. The incidence rates of fetal death (miscarriage and stillbirth together) and infertility reported by our radiographers were higher than had been reported by the British radiographers. An immediate plan of action is needed to protect our radiographers. Further studies are needed in this field taking into account all extraneous variables that may affect the reproductive health of radiographers. (author)

  14. Correlation of radiological assessment of congestive heart failure with left ventricular end-diastolic pressure

    International Nuclear Information System (INIS)

    Herman, P.G.; Kahn, A.; Kallman, C.E.; Rojas, K.A.; Bodenheimer, M.M.

    1988-01-01

    Left ventricular end-diastolic pressure (LVEDP) has been considered a reliable indicator of left ventricular function. The purpose of this study was to correlate the radiologic assessment of congestive heart failure with LVEDP. The population of the study consisted of 85 consecutive cases in four ranges of LVEDP ( 24). The PA chest radiographs obtained 1 day prior to cardiac catherization were assessed for radiological evidence of congestive heart failure and were graded from normal to abnormal (0-3). The results will be summarized in the authors' presentation. The discordance of radiological assessment of congestive heart failure in patients with elevated LVEDP will be discussed in light of recent advances in pathophysiologic understanding of left ventricular function and the impact of new classes of drugs in the management of these patients

  15. Radiographic analysis of the course of Legionella pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Lo, C.D.; MacKeen, A.D.; Campbell, D.R.; Fraser, D.B.; Marrie, T.J. (Dalhousie Univ., Halifax, Nova Scotia (Canada))

    1983-06-01

    The radiographic findings in the acute phase of Legionella pneumonia are generally non-specific and have been previously documented. A retrospective assessment of 12 patients with this bacterial pneumonia revealed that resolution of the radiographic findings was prolonged in five. The predominant feature in such patients is the transient finding of interstitial consolidation following the air-space consolidation, not unlike that of Mycoplasma or viral pneumonia. Eventual return to normal was evident in three patients and residual parenchymal fibrosis was noted in two patients.

  16. Radiographic analysis of the course of Legionella pneumonia

    International Nuclear Information System (INIS)

    Lo, C.D.; MacKeen, A.D.; Campbell, D.R.; Fraser, D.B.; Marrie, T.J.

    1983-01-01

    The radiographic findings in the acute phase of Legionella pneumonia are generally non-specific and have been previously documented. A retrospective assessment of 12 patients with this bacterial pneumonia revealed that resolution of the radiographic findings was prolonged in five. The predominant feature in such patients is the transient finding of interstitial consolidation following the air-space consolidation, not unlike that of Mycoplasma or viral pneumonia. Eventual return to normal was evident in three patients and residual parenchymal fibrosis was noted in two patients

  17. Cataracts, radiculomegaly, septal heart defects and hearing loss in two unrelated adult females with normal intelligence and similar facial appearance : Confirmation of a syndrome

    NARCIS (Netherlands)

    Aalfs, CM; Oosterwijk, JC; VanSchooneveld, MJ; Begeman, CJ; Wabeke, KB; Hennekam, RCM

    Two unrelated, adult females with normal intelligence are described. They show a similar clinical picture with a long and narrow face, congenital cataract, microphthalmia, microcornea, a high nasal bridge, a short nose, a broad nasal tip, a long philtrum, bilateral hearing loss, persistent primary

  18. Attitudes of radiographers to radiographer-led discharge: A survey

    International Nuclear Information System (INIS)

    Lumsden, Laura; Cosson, Philip

    2015-01-01

    Background: The traditional role of the Diagnostic Radiographer in image acquisition has gradually been extended through skill-mix, particularly to include abnormality detection. Aims: This research focused on the attitudes of Radiographers to Radiographer-led Discharge (RLD), where Radiographers discharge patients with minor injuries and perform tasks previously undertaken by Accident and Emergency staff. The effects of job role, hospital type, experience and whether RLD was used in the participant's trust were examined. Method: A multiple-indicator online questionnaire assessed attitudes to RLD. Snowball sampling was used with advertisement via emails, posters and cards, containing Quick Response (QR) codes. Statement responses were coded, with reverse coding for negative statements and total scores were calculated. A higher score represented a more positive attitude. Results: 101 questionnaires were completed (an estimated 30% response rate) and the mean total score was 84/115. 95% of participants supported radiographer involvement in abnormality detection, with 46.5% selecting RLD as the preferred system for minor injuries patients vs 48.5% preferring commenting alone. Discussion: Participants were positive about extending their role through RLD and felt confident in their image interpretation abilities, though expressed concern for the legal consequences of the role and adequate pay. Generalization of the results is limited due to the possible low response rate. Conclusion: Overall, participants demonstrated positive attitudes towards RLD but they also indicate the need for appropriate payment for any additional responsibility. These findings are promising for successful implementation of RLD, though larger-scale research including radiologists, business managers, A and E staff and patients would be beneficial. - Highlights: • 101 questionnaires were completed (an estimated 30% response rate). • 95% of participants supported radiographer involvement

  19. Amino acid transamination is crucial for ischaemic cardioprotection in normal and preconditioned isolated rat hearts--focus on L-glutamate

    DEFF Research Database (Denmark)

    Løfgren, Bo; Povlsen, Jonas Agerlund; Rasmussen, Lars Ege

    2010-01-01

    We have found that cardioprotection by l-glutamate mimics protection by classical ischaemic preconditioning (IPC). We investigated whether the effect of IPC involves amino acid transamination and whether IPC modulates myocardial glutamate metabolism. In a glucose-perfused, isolated rat heart model...... subjected to 40 min global no-flow ischaemia and 120 min reperfusion, the effects of IPC (2 cycles of 5 min ischaemia and 5 min reperfusion) and continuous glutamate (20 mm) administration during reperfusion on infarct size and haemodynamic recovery were studied. The effect of inhibiting amino acid...... transamination was evaluated by adding the amino acid transaminase inhibitor amino-oxyacetate (AOA; 0.025 mm) during reperfusion. Changes in coronary effluent, interstitial (microdialysis) and intracellular glutamate ([GLUT](i)) concentrations were measured. Ischaemic preconditioning and postischaemic glutamate...

  20. Enlarged Heart

    Science.gov (United States)

    ... rheumatic fever, a heart defect, infections (infectious endocarditis), connective tissue disorders, certain medications or radiation treatments for cancer, your heart may enlarge. Disease of the heart ...

  1. Insuficiência cardíaca com fração de ejeção normal Insuficiencia cardíaca con fracción de eyección normal Heart failure with normal ejection fraction

    Directory of Open Access Journals (Sweden)

    Meliza Goi Roscani

    2010-05-01

    multifactoriales, involucrando la rigidez pasiva del miocardio, la geometría ventricular, la fuerza de contención pericárdica y la interacción entre los ventrículos. Los objetivos principales del tratamiento son reducir la congestión venosa pulmonar, la frecuencia cardíaca y controlar las comorbilidades. Todavía no hay evidencias de que el uso de medicaciones específicas, como inhibidores de la enzima de conversión o betabloqueadores, interfieran en la mortalidad. Los factores de peor pronóstico incluyen la edad avanzada, presencia de disfunción renal, diabetes, clase funcional III y IV (NYHA y estado avanzado de disfunción diastólica, con patrón restrictivo al llenado ventricular. Otro aspecto viene cobrando espacio en la bibliografía es el cuestionamiento del papel de la disfunción sistólica en los cuadros de ICFEN. Todos estos aspectos se abordan detalladamente en la presente revisión.Heart failure with normal ejection fraction (HFNEF is a complex syndrome that has been broadly studied since the last decade. It is caused by diastolic ventricular dysfunction demonstrated by complementary methods, such as hemodynamic study or echocardiogram, in the presence of a normal ejection fraction (EF. It affects primarily elderly individuals with comorbidities, such as systemic arterial hypertension, coronary failure and obesity. The physiopathological mechanisms are complex and multifactorial, involving the myocardial passive stiffness, the ventricular geometry, the pericardial restraint and the interaction between the ventricles. The main objectives of the treatment were to decrease the pulmonary venous congestion and the heart rate and control the comorbidities. There is no strong evidence that the use of specific medications, such as the angiotensin-converting enzyme inhibitors or beta-blockers can influence mortality. The poorer prognostic factors include advanced age, presence of kidney dysfunction, diabetes, functional class III and IV (NYHA and advanced

  2. Caries detection in dental radiographs

    International Nuclear Information System (INIS)

    Dunn, S.M.

    1987-01-01

    Caries, or the decay of teeth are difficult to automatically detect in dental radiographs because of the small area of the image that is occupied by the decay. Images of dental radiographs has distinct regions of homogeneous gray levels, and therefore naturally lead to a segmentation based automatic caries detection algorithm. This paper describes a method for caries detection based on a multiclass, area independent thresholding and segmenting scheme. This multiclass thresholding algorithm is an extension of the uniform error threshold, an area independent, distribution free thresholding method used for images of only two classes of objects. The authors first consider the problem of caries detection and the image features that characterize the presence of caries. Next, the uniform error threshold is reviewed, and the general multiclass uniform error threshold algorithm is presented. This algorithm is used to automatically detect caries in dental radiographs

  3. Interpretation and evaluation of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    After digestion, the interpreter must interpreted and evaluate the image on film, usually many radiograph stuck in this step, if there is good density, so there are no problem. This is a final stage of radiography work and this work must be done by level two or three radiographer. This is a final stages before the radiographer give a result to their customer for further action. The good interpreter must know what kind of artifact, is this artifact are dangerous or not and others. In this chapter, the entire artifact that usually showed will be discussed briefly with the good illustration and picture to make the reader understand and know the type of artifact that exists.

  4. Industrial radiography on radiographic paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-11-01

    An investigation was performed to compare the quality of radiographic paper with that of X-ray film, after a review had been made of the rather scarce literature on the subject. The equipment used throughout the investigation is described, and characteristic curves for Agfa-Gevaert and Kodak papers exposed with different intensifying screens in the low and intermediate voltage range are reproduced. The relative speed, contrast and exposure latitude were computed from these curves. The quality of the radiographic image was checked on U/Al blocks and plates, Al and Fe blocks, and fiber-reinforced composites. Exposure charts for Al and Fe were made for various paper and screen combinations. Both the sharpness of the radiographic image as well as the influence of processing on speed and contrast were checked. Examples are given of the practical application of the paper for radiography of castings, weldings, solderings, assemblies, etc. (author)

  5. Digital image analysis of NDT radiographs

    International Nuclear Information System (INIS)

    Graeme, W.A. Jr.; Eizember, A.C.; Douglass, J.

    1989-01-01

    Prior to the introduction of Charge Coupled Device (CCD) detectors the majority of image analysis performed on NDT radiographic images was done visually in the analog domain. While some film digitization was being performed, the process was often unable to capture all the usable information on the radiograph or was too time consuming. CCD technology now provides a method to digitize radiographic film images without losing the useful information captured in the original radiograph in a timely process. Incorporating that technology into a complete digital radiographic workstation allows analog radiographic information to be processed, providing additional information to the radiographer. Once in the digital domain, that data can be stored, and fused with radioscopic and other forms of digital data. The result is more productive analysis and management of radiographic inspection data. The principal function of the NDT Scan IV digital radiography system is the digitization, enhancement and storage of radiographic images

  6. Endodontic radiography: who is reading the digital radiograph?

    Science.gov (United States)

    Tewary, Shalini; Luzzo, Joseph; Hartwell, Gary

    2011-07-01

    Digital radiographic imaging systems have undergone tremendous improvements since their introduction. Advantages of digital radiographs over conventional films include lower radiation doses compared with conventional films, instantaneous images, archiving and sharing images easily, and manipulation of several radiographic properties that might help in diagnosis. A total of 6 observers including 2 endodontic residents, 3 endodontists, and 1 oral radiologist evaluated 150 molar digital periapical radiographs to determine which of the following conditions existed: normal periapical tissue, widened periodontal ligament, or presence of periapical radiolucency. The evaluators had full control over the radiograph's parameters of the Planmeca Dimaxis software program. All images were viewed on the same computer monitor with ideal vie-wing conditions. The same 6 observers evaluated the same 150 digital images 3 months later. The data were analyzed to determine how well the evaluators agreed with each other (interobserver agreement) for 2 rounds of observations and with themselves (intraobserver agreement). Fleiss kappa statistical analysis was used to measure the level of agreement among multiple raters. The overall Fleiss kappa value for interobserver agreement for the first round of interpretation was 0.34 (P value for interobserver agreement for the second round of interpretation was 0.35 (P fair (0.2-0.4) agreement among the 6 raters at both observation periods. A weighted kappa analysis was used to determine intraobserver agreement, which showed on average a moderate agreement. The results indicate that the interpretation of a dental radiograph is subjective, irrespective of whether conventional or digital radiographs are used. The factors that appeared to have the most impact were the years of experience of the examiner and familiarity of the operator with a given digital system. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All

  7. Normal and abnormal growth plate

    International Nuclear Information System (INIS)

    Kumar, R.; Madewell, J.E.; Swischuk, L.E.

    1987-01-01

    Skeletal growth is a dynamic process. A knowledge of the structure and function of the normal growth plate is essential in order to understand the pathophysiology of abnormal skeletal growth in various diseases. In this well-illustrated article, the authors provide a radiographic classification of abnormal growth plates and discuss mechanisms that lead to growth plate abnormalities

  8. PACS influence the radiographer's work

    International Nuclear Information System (INIS)

    Fridell, Kent; Aspelin, Peter; Edgren, Lars; Lindskoeld, Lars; Lundberg, Nina

    2009-01-01

    Radiological departments are changing rapidly due to the implementation of digital images and PACS (Picture Archiving and Communication Systems). The introduction of new technology seems to dissolve boundaries between the professions in the work environment where the technology is introduced. This process tends to change the organization and its routines. The aim of this qualitative study is to explore changes in radiographers' work with regard to skills, work practice and technology. The study used open-ended interviews to explore the radiographers' perceptions of such changes, and to identify problems and solutions pertaining to work practice. Inspiration is taken from grounded theory to explain the changes in work that were found. Respondents were selected from a total of 133 potential participants as a theoretical or purposive sample. The changing trends within the professional role indicated that radiographers, as image producers, shifted their focus from the ability to set the optimal exposure parameters in order to obtain the optimal image for diagnosis to become expert in exposure parameters, projection techniques and diagnostic practice, having multifaceted skills, as being the jack of all trades. When implementing PACS there was an obvious change in image production. At the start there were visions of new routines, and therefore the radiographers became early adopters to the new technology; in practice the organization was stacked in old routines, as the routines were inflexible and PACS work was pushed into old work routines. Although inflexible, this does not mean that they cannot change, and obviously in 2006 new routines had been implemented making it possible for the radiographers in finding new ways for collaborating with colleagues. The new technology immediately created a vision of improved service to the clinicians. In order to optimize the service the radiographers developed an insight into the need for a more comprehensive change in work using

  9. Radiographic features of pleural effusions in pulmonary embolism

    International Nuclear Information System (INIS)

    Bynum, L.J.; Wilson, J.E.

    1978-01-01

    A prospective analysis of 155 patients with pulmonary embolism was undertaken to describe the radiographic characteristics of associated pleural effusions and related abnormalities. Approximately one half of these patients had pleural effusions. Patients with other potential causes of effusion, such as heart failure, pneumonia, or cancer, were eliminated from further analysis. In the remaining 62 patients, radiographic evidence of pulmonary infarction accompanied pleural effusions in one half of the cases. One third of patients with parenchymal consolidation had no evidence of effusion. Atelectasis and other nonspecific radiographic abnormalities occurred in less than one fifth of the cases. Typically, pleural effusions were small and unilateral, appeared soon after symptoms of thromboembolism began, and tended to reach their maximal size very early in the course of the disorder. Pulmonary infarction was associated with larger effusions that cleared more slowly and were more often bloody in appearance on thoracentesis. Chest pain occurred in all but one patient and was a valuable diagnostic clue. Pain and pleural effusions were always ipsilateral and almost always unilateral, but neither correlated well with the presence or time course of infarction. Effusions that were delayed in onset or that enlarged late in the course were associated with recurrent pulmonary embolism or superinfection. These radiographic features may be helpful in the diagnosis and management of pulmonary embolism

  10. Radiographic features of paediatric pneumocystis pneumonia - a historical perspective

    International Nuclear Information System (INIS)

    Pitcher, R.D.; Zar, H.J.

    2008-01-01

    Aim: To determine differences between the plain radiographic features of paediatric pneumocystis pneumonia (PCP) recorded before the emergence of human immunodeficiency virus (HIV) in 1982 and those documented in the HIV era. To establish differences in the radiographic features of PCP documented in HIV-infected children in developed and developing countries. Method: A Medline search of articles was conducted from 1950 to 2006, using the terms 'pneumocystis pneumonia in children' and 'chest radiographic features' or 'bilateral opacification' or 'lobar consolidation' or 'asymmetrical opacification' or 'pneumatocoeles' or 'cavities' or 'pneumothorax' or 'pneumomediastinum' or 'pleural effusion' or 'mediastinal adenopathy' or 'nodules' or 'normal chest radiography'. Appropriate articles were retrieved, radiological data extracted, reference lists examined and hand searches of referenced articles conducted. Results: Diffuse bilateral 'ground-glass' or alveolar pulmonary opacification, which may show some asymmetry, has been consistently documented as the commonest radiographic finding in childhood PCP throughout the period under review. The less common radiological features of PCP in children are similar to those in adults. In developed countries, PCP-related pulmonary air cysts have been reported at an earlier age in HIV-infected children, compared with uninfected children. PCP-related air cysts, pneumothorax, and pneumomediastinum have been reported in children in developed but not in developing countries. Conclusion: The radiological features of paediatric PCP documented before the HIV epidemic are similar to those recorded in the HIV era. Further study of the determinants of the uncommon radiographic features in children is warranted

  11. Cash's textbook of chest, heart and vascular disorders for physiotherapists

    International Nuclear Information System (INIS)

    Downie, P.A.; Innocenti, D.M.; Jackson, S.E.

    1987-01-01

    A very high proportion of the patients treated by physiotherapy will have had a chest radiograph (x-ray) either because their primary disease is pulmonary or there is some long standing heart or lung illness which should be taken into account during the management of an acute problem. This chapter outlines the principles involved in reading the radiograph

  12. The Restoration of Chronotropic CompEtence in Heart Failure PatientS with Normal Ejection FracTion (RESET) Study: Rationale and Design

    Science.gov (United States)

    Kass, David A.; Kitzman, Dalane W.; Alvarez, Guy E.

    2009-01-01

    Background Heart failure with preserved ejection fraction (HFpEF) is the predominant form of HF among the elderly and in women. However, there are few if any evidence-based therapeutic options for HFpEF. The chief complaint of HFpEF is reduced tolerance to physical exertion. Recent data revealed that one potential mechanism of exertional intolerance in HFpEF patients is inadequate chronotropic response. Although there is considerable evidence demonstrating the benefits of rate-adaptive pacing (RAP) provided from implantable cardiac devices in patients with an impaired chronotropic response, the effect of RAP in HFpEF is unknown. Methods and Results The RESET study is a prospective, multi-center, double-blind, randomized with stratification, study assessing the effect of RAP on peak VO2 and quality of life. RAP therapy will be evaluated in a cross-over paired fashion for each patient within each study stratum. Study strata are based on patient beta-blocker usage at time of enrollment. The study is powered to assess the impact of pacing independently in both strata. Conclusions The RESET study seeks to evaluate the potential benefit of RAP in patients with symptomatic mild to moderate HFpEF and chronotropic impairment. Study enrollment began in July 2008. PMID:20123314

  13. Quantitative analysis of bowel gas by plain abdominal radiograph combined with computer image processing

    International Nuclear Information System (INIS)

    Gao Yan; Peng Kewen; Zhang Houde; Shen Bixian; Xiao Hanxin; Cai Juan

    2003-01-01

    Objective: To establish a method for quantitative analysis of bowel gas by plain abdominal radiograph and computer graphics. Methods: Plain abdominal radiographs in supine position from 25 patients with irritable bowel syndrome (IBS) and 20 health controls were studied. A gastroenterologist and a radiologist independently conducted the following procedure on each radiograph. After the outline of bowel gas was traced by axe pen, the radiograph was digitized by a digital camera and transmitted to the computer with Histogram software. The total gas area was determined as the pixel value on images. The ratio of the bowel gas quantity to the pixel value in the region surrounded by a horizontal line tangential to the superior pubic symphysis margin, a horizontal line tangential to the tenth dorsal vertebra inferior margin, and the lateral line tangential to the right and left anteriosuperior iliac crest, was defined as the gas volume score (GVS). To examine the sequential reproducibility, a second plain abdominal radiograph was performed in 5 normal controls 1 week later, and the GVS were compared. Results: Bowel gas was easily identified on the plain abdominal radiograph. Both large and small intestine located in the selected region. Both observers could finish one radiographic measurement in less than 10 mins. The correlation coefficient between the two observers was 0.986. There was no statistical difference on GVS between the two sequential radiographs in 5 health controls. Conclusion: Quantification of bowel gas based on plain abdominal radiograph and computer is simple, rapid, and reliable

  14. Evaluation of the distortion rate of panoramic and peri apical radiographs in erupted third molar inclination

    International Nuclear Information System (INIS)

    Ezoddini Ardakani, F.; Zangouie Booshehri, M.; Behniafar, B.

    2011-01-01

    Panoramic and peri apical radiographs are normally used in impacted third molar teeth surgeries. The aim of the present study was to evaluate and compare the distortion of the erupted third molar teeth on panoramic and peri apical radiographs. Patients and Methods: A total of 44 radiographs were obtained of 22 patients (age range, 18-24 years) referred to the faculty of dentistry for orthodontic treatment. A plaster cast was prepared and panoramic radiography was taken for all patients to plan the orthodontic treatment and peri apical radiography was taken for investigation of tooth structure details. Therefore, a total of 66 views and samples were studied by two methods: 1) Measuring the angle between the longitudinal plane of the third molar and occlusal plane. 2) Measuring the angle between the longitudinal plane of second and third molar. Finally, 132 records were evaluated by one individual. Results: There was no significant statistical difference between the mean position of the third molar on panoramic, peri apical radiographs and the casts. However, measurements of the third molars on peri apical radiographs were slightly closer to the measurements of the casts compared to the panoramic radiographs. Conclusion: Distortion does not have a specific effect on the diagnosis of the position of the third erupted molars by peri apical or panoramic radiographs, though various studies have shown that these radiographs have an amount of distortion and peri apical radiographical distortion is less than that in panoramic radiography.

  15. Chest radiographic manifestations of scrub typhus

    Directory of Open Access Journals (Sweden)

    KPP Abhilash

    2016-01-01

    Full Text Available Background and Rationale: Respiratory system involvement in scrub typhus is seen in 20–72% of patients. In endemic areas, good understanding and familiarity with the various radiologic findings of scrub typhus are essential in identifying pulmonary complications. Materials and Methods: Patients admitted to a tertiary care center with scrub typhus between October 2012 and September 2013 and had a chest X ray done were included in the analysis. Details and radiographic findings were noted and factors associated with abnormal X-rays were analyzed. Results: The study cohort contained 398 patients. Common presenting complaints included fever (100%, generalized myalgia (83%, headache (65%, dyspnea (54%, cough (24.3%, and altered sensorium (14%. Almost half of the patients (49.4% had normal chest radiographs. Common radiological pulmonary abnormalities included pleural effusion (14.6%, acute respiratory distress syndrome (14%, airspace opacity (10.5%, reticulonodular opacities (10.3%, peribronchial thickening (5.8%, and pulmonary edema (2%. Cardiomegaly was noted in 3.5% of patients. Breathlessness, presence of an eschar, platelet counts of 2 mg/dL had the highest odds of having an abnormal chest radiograph. Patients with an abnormal chest X-ray had a higher requirement of noninvasive ventilation (odds ratio [OR]: 13.98; 95% confidence interval CI: 5.89–33.16, invasive ventilation (OR: 18.07; 95% CI: 6.42–50.88, inotropes (OR: 8.76; 95% CI: 4.35–17.62, higher involvement of other organ systems, longer duration of hospital stay (3.18 ± 3 vs. 7.27 ± 5.58 days; P< 0.001, and higher mortality (OR: 4.63; 95% CI: 1.54–13.85. Conclusion: Almost half of the patients with scrub typhus have abnormal chest radiographs. Chest radiography should be included as part of basic evaluation at presentation in patients with scrub typhus, especially in those with breathlessness, eschar, jaundice, and severe thrombocytopenia.

  16. Radiographic analysis of temporomandibular joint arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    You, Dong Soo [Department of Oral Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1984-11-15

    The author analysed the bone changes, the positional relationships between condylar head and articular fossa, and the interrelationship between the bone changes and the abnormal position of condylar head, from 1,036 radiographs of 259 patients with temporomandibular joint arthrosis, which were obtained by the oblique-lateral transcranial projection and orthopantomograms. The results were as follows: 1. Among the radiographic bone changes of the temporomandibular joint arthrosis, deformity was 36..90% (217 cases), sclerosis 34.18% (201 cases), erosive change 25.58% (152 cases) and marginal proliferation 3.06% (18 cases) respectively. 2. In the positional changes between condylar head and articular fossa, the downward positioning of condylar head in centric occlusion was most frequent (36.90%), of which frequency was significantly higher than forward positioning (11.22%) and backward positioning (4.76%) in same condition. Also, radiographs showed that the enlargement of articular space showed higher frequency than its narrowing. In the opening position of mouth, the restrict ed movement of condylar head within articular fossa was most frequent (35.03%). The forward positioning and the downward positioning was 15.65% and 9.52% respectively. Also, radiographs revealed that the incomplete movement or no positional change of condylar head was most frequent. 3. In the interrelationship between bone changes and abnormal position of condylar head, deformity was 42.79% in the cases of downward positioning of condylar head in centric occlusion and 37.50% in those of normal positioning of condylar head in same condition. This revealed that deformity was most frequent bone change in above condylar positionings. However, erosive change was 34.62% in the cases of downward positioning of condylar head in centric occlusion and 33 .33% in those of forward positioning. In opening position of condylar head, and deformity in the cases of norma l positioning, forward positioning and

  17. Radiographic analysis of temporomandibular joint arthrosis

    International Nuclear Information System (INIS)

    You, Dong Soo

    1984-01-01

    The author analysed the bone changes, the positional relationships between condylar head and articular fossa, and the interrelationship between the bone changes and the abnormal position of condylar head, from 1,036 radiographs of 259 patients with temporomandibular joint arthrosis, which were obtained by the oblique-lateral transcranial projection and orthopantomograms. The results were as follows: 1. Among the radiographic bone changes of the temporomandibular joint arthrosis, deformity was 36..90% (217 cases), sclerosis 34.18% (201 cases), erosive change 25.58% (152 cases) and marginal proliferation 3.06% (18 cases) respectively. 2. In the positional changes between condylar head and articular fossa, the downward positioning of condylar head in centric occlusion was most frequent (36.90%), of which frequency was significantly higher than forward positioning (11.22%) and backward positioning (4.76%) in same condition. Also, radiographs showed that the enlargement of articular space showed higher frequency than its narrowing. In the opening position of mouth, the restrict ed movement of condylar head within articular fossa was most frequent (35.03%). The forward positioning and the downward positioning was 15.65% and 9.52% respectively. Also, radiographs revealed that the incomplete movement or no positional change of condylar head was most frequent. 3. In the interrelationship between bone changes and abnormal position of condylar head, deformity was 42.79% in the cases of downward positioning of condylar head in centric occlusion and 37.50% in those of normal positioning of condylar head in same condition. This revealed that deformity was most frequent bone change in above condylar positionings. However, erosive change was 34.62% in the cases of downward positioning of condylar head in centric occlusion and 33 .33% in those of forward positioning. In opening position of condylar head, and deformity in the cases of norma l positioning, forward positioning and

  18. Effects of continuous triiodothyronine infusion on the tricarboxylic acid cycle in the normal immature swine heart under extracorporeal membrane oxygenation in vivo.

    Science.gov (United States)

    Kajimoto, Masaki; Priddy, Colleen M O'Kelly; Ledee, Dolena R; Xu, Chun; Isern, Nancy; Olson, Aaron K; Portman, Michael A

    2014-04-15

    Extracorporeal membrane oxygenation (ECMO) is frequently used in infants with postoperative cardiopulmonary failure. ECMO also suppresses circulating triiodothyronine (T3) levels and modifies myocardial metabolism. We assessed the hypothesis that T3 supplementation reverses ECMO-induced metabolic abnormalities in the immature heart. Twenty-two male Yorkshire pigs (age: 25-38 days) with ECMO received [2-(13)C]lactate, [2,4,6,8-(13)C4]octanoate (medium-chain fatty acid), and [U-(13)C]long-chain fatty acids as metabolic tracers either systemically (totally physiological intracoronary concentration) or directly into the coronary artery (high substrate concentration) for the last 60 min of each protocol. NMR analysis of left ventricular tissue determined the fractional contribution of these substrates to the tricarboxylic acid cycle. Fifty percent of the pigs in each group received intravenous T3 supplement (bolus at 0.6 μg/kg and then continuous infusion at 0.2 μg·kg(-1)·h(-1)) during ECMO. Under both substrate loading conditions, T3 significantly increased the fractional contribution of lactate with a marginal increase in the fractional contribution of octanoate. Both T3 and high substrate provision increased the myocardial energy status, as indexed by phosphocreatine concentration/ATP concentration. In conclusion, T3 supplementation promoted lactate metabolism to the tricarboxylic acid cycle during ECMO, suggesting that T3 releases the inhibition of pyruvate dehydrogenase. Manipulation of substrate utilization by T3 may be used therapeutically during ECMO to improve the resting energy state and facilitate weaning.

  19. Radiographic testing in concrete structures

    International Nuclear Information System (INIS)

    Oliveira, D. de

    1987-01-01

    The radiographic testing done in concrete structures is used to analyse the homogeneity, position and corrosion of armatures and to detect discontinuity in the concrete such as: gaps, cracks and segregations. This work develops a Image quality Indicator (IQI) with an adequated sensibility to detect discontinuites based on BS4408 norm. (E.G.) [pt

  20. Radiographic signs of non-venous placement of intended central venous catheters in children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Erin C. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-02-15

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  1. A radiographic study of the development of the sheep carpus from birth to 18 months of age

    International Nuclear Information System (INIS)

    Saber, A.S.; Bolbol, A.E.; Schenk-Saber, B.

    1989-01-01

    Osseous development of the carpus of six clinically normal lambs was studied radiographically from birth to 18 months of age with the aim of forming a standard radiographic evaluation and reference for the sheep carpus. Radiographic data consisted of 200 radiographs. Dorsopalmar and lateromedial projections were made daily during the first week, then weekly until the sixth month, and finally monthly until 18 month of age. Ten radiographs were selected to illustrate normal development of the carpus. The distal ulnar epiphysis reached the ulnar carpal bone at the third week, but remained separate from the ulnar diaphysis until six months of age. The ulnar epiphysis was radiographically fused with the ulnar diaphysis at thirteen months of age

  2. The radiographic observation of the cervical strain

    International Nuclear Information System (INIS)

    Rhee, Chung Sik

    1972-01-01

    A total of 100 cases of cervical disorders were analysed of clinical signs and symptoms. The cervical strain is proved by the loss of normal lordotic curvature of the cervical spinal column on the lateral x-ray film in Ewha University Hospital from January, 1970 to december 1971 with the following results. 1. The 53 cervical strain was diagnosed in radiographic study for its abnormal locations. The hyperextension with abnormal curve is twice more after than hyperflection type. 2. The most frequent location of the cervical strain is demonstrated in the 4-6 th cervical spinal bodies (80%). 3. Most pronounced symptoms of cervical strain are local tenderness (40%), limitation of motion (17%) and radiating pain (15%). 4. The ratio of the sex incidence of male female was 3:2

  3. The radiographic observation of the cervical strain

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Chung Sik [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    1972-12-15

    A total of 100 cases of cervical disorders were analysed of clinical signs and symptoms. The cervical strain is proved by the loss of normal lordotic curvature of the cervical spinal column on the lateral x-ray film in Ewha University Hospital from January, 1970 to december 1971 with the following results. 1. The 53 cervical strain was diagnosed in radiographic study for its abnormal locations. The hyperextension with abnormal curve is twice more after than hyperflection type. 2. The most frequent location of the cervical strain is demonstrated in the 4-6 th cervical spinal bodies (80%). 3. Most pronounced symptoms of cervical strain are local tenderness (40%), limitation of motion (17%) and radiating pain (15%). 4. The ratio of the sex incidence of male female was 3:2.

  4. A radiographic comparative study of two series of skeletally mature clubfeet treated by two different protocols

    Energy Technology Data Exchange (ETDEWEB)

    Ippolito, E.; Caterini, R.; Farsetti, P. [Department of Orthopaedic Surgery, University of Rome ' ' Tor Vergata' ' , Via della Ricerca Scientifica 135, 00173, Rome (Italy); Fraracci, L.; Di Mario, M. [Department of Radiology, IRCCS Santa Lucia Institute, Via Ardeatina 306, 00179, Rome (Italy)

    2003-08-01

    To compare the radiographic features of two series of congenital clubfeet to determine whether a different treatment protocol may influence the radiographic results at the end of skeletal growth. Two series of patients with congenital clubfeet, treated by two different manipulative techniques and by two different complementary soft tissue release operations, were radiographically studied at skeletal maturity. Twenty-one normal feet of the unilateral cases in both series served as controls. Anteroposterior and lateral radiographs of the feet were taken with the patient standing, and several radiographic parameters were studied. The size of the talus and calcaneus and the height of the talar trochlea were smaller than normal in all cases of clubfeet, were similar in both series and were not influenced by treatment, whereas all the other radiographic parameters studied were more or less different between the two series and seemed to be influenced by treatment. In no treated clubfoot of either series was a normal radiographic foot anatomy restored, not even in those feet that had an excellent clinical result. (orig.)

  5. A radiographic comparative study of two series of skeletally mature clubfeet treated by two different protocols

    International Nuclear Information System (INIS)

    Ippolito, E.; Caterini, R.; Farsetti, P.; Fraracci, L.; Di Mario, M.

    2003-01-01

    To compare the radiographic features of two series of congenital clubfeet to determine whether a different treatment protocol may influence the radiographic results at the end of skeletal growth. Two series of patients with congenital clubfeet, treated by two different manipulative techniques and by two different complementary soft tissue release operations, were radiographically studied at skeletal maturity. Twenty-one normal feet of the unilateral cases in both series served as controls. Anteroposterior and lateral radiographs of the feet were taken with the patient standing, and several radiographic parameters were studied. The size of the talus and calcaneus and the height of the talar trochlea were smaller than normal in all cases of clubfeet, were similar in both series and were not influenced by treatment, whereas all the other radiographic parameters studied were more or less different between the two series and seemed to be influenced by treatment. In no treated clubfoot of either series was a normal radiographic foot anatomy restored, not even in those feet that had an excellent clinical result. (orig.)

  6. Importance of radiographic monitoring of endoscopic sphincterotomy

    International Nuclear Information System (INIS)

    Greenberg, H.M.; Goldberg, H.I.; Shapiro, H.A.

    1981-01-01

    The radiographic features of endoscopic sphincterotomies performed in 44 patients were evaluated. Radiographic landmarks aided in proper sphincterotome placement and also disclosed conditions and anatomic variations that made catheter placement difficult. Fluoroscopic and radiographic monitoring not only assisted the performance of endoscopic sphincterotomy, but also confirmed successful results and revealed reasons for failure. Radiographic changes in the biliary tract after sphincterotomy, as well as potential complications of sphincterotomy, are discussed and illustrated

  7. Diagnostic value of the chest radiograph in asymptomatic neonates with a cardiac murmur

    International Nuclear Information System (INIS)

    Oeppen, R.S.; Fairhurst, J.J.; Argent, J.D.

    2002-01-01

    AIM: To establish the diagnostic accuracy and diagnostic usefulness of the chest radiograph in asymptomatic neonates with cardiac murmurs. PATIENTS AND METHODS: The chest radiographs of 68 asymptomatic neonates with cardiac murmurs were analysed retrospectively. The radiographs were anonymized and then evaluated for the presence or absence of cardiac disease by six radiologists, three who regularly interpret neonatal chest radiographs and three who do so infrequently. The eventual diagnosis for each neonate and the impact of the chest radiograph and original report on patient management were established by review of the clinical case notes. RESULTS: The results for each observer were expressed in 2 x 2 contingency tables and statistical analysis was performed using Fisher's exact test. The radiologists who were experienced in reporting neonatal chest radiographs achieved statistically significant results (P = 0.003, P = 0.002 andP = 0.007) compared with those who were less experienced (P = 0.13, P = 0.16 andP = 0.09). Review of the case notes established that the chest radiograph and original report did not influence clinical management in any of the 68 cases studied. CONCLUSIONS: Radiologists who frequently report neonatal chest radiographs achieve high accuracy in differentiating cardiac from non-cardiac disease. However, inaccuracies are unavoidable as radiological evidence of cardiac disease is often not present. A false-positive result could cause undue anxiety while a false-negative report could result in the omission of further investigations. Furthermore, a chest radiograph is unlikely to provide the definitive diagnosis. Chest radiographs did not appear to influence patient management in this study and cannot be recommended in the initial evaluation of the asymptomatic neonate with a heart murmur. Oeppen, R.S. et al. (2002)

  8. 21 CFR 892.1840 - Radiographic film.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film. 892.1840 Section 892.1840 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin sheet of radiotransparent material coated on one or both...

  9. Radiographic diagnosis of hereditary chondrodysplasia in newborn lambs

    International Nuclear Information System (INIS)

    Vanek, J.A.; Walter, P.A.; Alstad, A.D.

    1989-01-01

    Normal appearing Suffolk lambs affected with hereditary chondrodysplasia (HC) and normal appearing unaffected lambs were radiographed at birth, and at 2, 4, and 8 weeks of age. In affected lambs, lesions were seen consistently in the elbows, shoulders, sternum, and spine. Similar lesions were not identified in unaffected lambs. A malformed Corriedale lamb was radiographed to compare its lesions to those seen in HC. The Corriedale lamb had islands of ossification of the anconeal process similar to those identified in lambs with signs of HC at birth. The islands of ossification seen in the Corriedale lamb were fused by 2 months of age, whereas elbow lesions seen in lambs with HC increased in severity during the same period

  10. Radiographic evaluation of maxillofacial fractures

    International Nuclear Information System (INIS)

    Litwan, M.; Fliegel, C.

    1986-01-01

    The course and configuration of typical maxillofacial fractures (type Le Fort I-III) and lateral maxillary fractures including the zygomatic arch were reconstructed in detail by application of barium paste on a bony skull and radiogrpahs in standard projections were performed and evaluated. It was obvious from the resulting radiographs that for most maxillofacial fractures a half axial or Water's view was most helpful. Lateral views only give additional information when there is a considerable degree of dislocation of fragments. Comparison with a prediatric skull of 8 years of age demonstrated that fractures of the zygomatic arch in this age group cannot be demonstrated by the typical submento-vertical view, but are shown on a Towne projection. The radiographic appearance of important maxillofacial fractures is demonstrated. The necessity of further studies in cases where reconstructive surgery appears necessary is discussed and CT rather then conventional tomography is advocated. (orig.) [de

  11. Heart Failure

    Science.gov (United States)

    Heart failure is a condition in which the heart can't pump enough blood to meet the body's needs. Heart failure does not mean that your heart has stopped ... and shortness of breath Common causes of heart failure are coronary artery disease, high blood pressure and ...

  12. Occupational health and the radiographer

    International Nuclear Information System (INIS)

    Stronach, T.

    1990-01-01

    This paper identifies some of the occupational health hazards faced by radiographers in the hospital environment. There has been very little work done in this area in the past, and as the subject is so large this paper can do little other than raise some of the issues . The hazards addressed include: radiation, ergonomics, chemical, environmental, biological, occupational injury and accident, stress. 14 refs., 2 figs

  13. Radiographers' performance in chest X-ray interpretation: the Nigerian experience

    Science.gov (United States)

    Egbe, N O; Akpan, B E

    2015-01-01

    Objective: To assess the performance of Nigerian radiographers in interpretation of plain chest radiographs and to assess whether age, years since qualification and sector of practice are associated with performance. Methods: A test set of 50 radiographs containing 23 cases with no pathology (normal) and 27 abnormal cases (cardiopulmonary conditions) independently confirmed by 3 radiologists were presented to 51 radiographers in a random order. Readers independently evaluated radiographs for absence or presence of disease and stated the location, radiographic features and diagnosis. Readers self-reported their age, years since qualification and sector of practice. Receiver operating characteristic was used to assess the performance. Mann–Whitney U test was used to assess whether age, years since qualification and sector of practice were associated with performance. Results: Mean location sensitivity was 88.9 [95% confidence interval (CI), 0.787–0.980]. Mean sensitivity and specificity were 76.9 (95% CI, 0.658–0.864) and 79.8 (95% CI, 0.658–0.864), respectively. Age was not associated with performance (p = 0.07). Number of years qualified as radiographer (p = 0.005) and private practice (p = 0.004) were positively associated with performance. Conclusion: Nigerian radiographers can correctly report chest radiographs to a reasonable standard, and performance is associated with number of years since qualification and the sector of practice. Advances in knowledge: There are less than 300 radiologists serving a Nigerian population of about 170 million; therefore, X-ray interpretation by radiographers deserves consideration. Nigerian radiographers have potential to interpret chest X-ray in the clinical setting, and this may significantly improve radiology service delivery in this region. PMID:25966290

  14. Chest radiographic abnormalities in HIV-infected African children: a longitudinal study.

    Science.gov (United States)

    Pitcher, Richard D; Lombard, Carl J; Cotton, Mark F; Beningfield, Stephen J; Workman, Lesley; Zar, Heather J

    2015-09-01

    There is limited knowledge of chest radiographic abnormalities over time in HIV-infected children in resource-limited settings. To investigate the natural history of chest radiographic abnormalities in HIV-infected African children, and the impact of antiretroviral therapy (ART). Prospective longitudinal study of the association of chest radiographic findings with clinical and immunological parameters. Chest radiographs were performed at enrolment, 6-monthly, when initiating ART and if indicated clinically. Radiographic abnormalities were classified as normal, mild or moderate severity and considered persistent if present for 6 consecutive months or longer. An ordinal multiple logistic regression model assessed the association of enrolment and time-dependent variables with temporal radiographic findings. 258 children (median (IQR) age: 28 (13-51) months; median CD4+%: 21 (15-24)) were followed for a median of 24 (18-42) months. 70 (27%) were on ART at enrolment; 130 (50%) (median age: 33 (18-56) months) commenced ART during the study. 154 (60%) had persistent severe radiographic abnormalities, with median duration 18 (6-24) months. Among children on ART, 69% of radiographic changes across all 6-month transition periods were improvements, compared with 45% in those not on ART. Radiographic severity was associated with previous radiographic severity (OR=120.80; 95% CI 68.71 to 212.38), lack of ART (OR=1.72; 95% CI 1.29 to 2.27), enrolment age ART was beneficial, reducing the risk of radiographic deterioration or increasing the likelihood of radiological improvement. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Observer POD for radiographic testing

    Energy Technology Data Exchange (ETDEWEB)

    Kanzler, Daniel; Mueller, Christina; Bertovic, Marija [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany); Pitkaenen, Jorma [Posiva Oy, Eurajoki (Finland)

    2013-07-01

    The radiographic testing is an important non-destructive testing method, especially in industrial areas where people could be injured in case of failing of a component. There it is a mighty method to find volumetric defects. As bigger the penetrated length of the defect in the component is, as bigger is the radiographic contrast. The detectability of volumetric defects in its turn is not only depending on the contrast but also on the noise, the defect area and its shape. The currently applied POD approach uses mostly only the contrast and the noise as detection threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the area of the defect. The presentation shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data. This approach was developed within a joint project with the company POSIVA, which is constructing a final depository for high active nuclear fuels in Finland. Radiographic testing is one of the NDT-methods they use to test the electron beam welds of the copper canisters. The copper canisters will be used in the depository as a corrosion barrier within the waste management concept. (Published as a poster session.)

  16. Automating the radiographic NDT process

    International Nuclear Information System (INIS)

    Aman, J.K.

    1986-01-01

    Automation, the removal of the human element in inspection, has not been generally applied to film radiographic NDT. The justication for automating is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 8 x 10 9 bits per 14 x 17. The equivalent to 2200 computer floppy discs. Parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, computer aided interpretation appears on the horizon. A unit which laser scans a 14 x 17 (inch) film in 6 - 8 seconds can digitize film information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for Film Digital Radiography System) is moving toward 50 micron (*approx* 16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. We expect the automated system to appear first in parts (modules) as certain operations are automated. The future will see it all come together in an automated film radiographic NDT system (author) [pt

  17. A Radiographic Study of Odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ho; Choi, Karp Shik [Dept. of Dental Radiology, College of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    1998-02-15

    The purpose of this study was to obtain information on the clinical and radiographic features of the odontomas in the jaws. For this study, the authors examined and analyzed the clinical records and radiographs of 119 patients who had lesion of odontoma diagnosed by clinical and radiographic examinations. The obtained results were as follows: 1. Odontoma occurred the most frequently in the 2nd decade (45.4%) and occurred more frequently in males (60.5%) than in females (39.5%). 2. The most common clinical symptom was the delayed eruption of the teeth (34.2%). 3. The type of lesions was mainly observed as compound odontoma (80.8%), and internal pattern of the complex odontoma was unevenly radiopaque (73.9%). 4. The compound odontoma frequently occurred in anterior portion of the maxilla (57.7%) and mandible (30.9%), and complex odontoma frequently occurred in anterior portion of maxilla (34.8%) and posterior portion of mandible (30.5%). 5. The effects on adjacent teeth were impaction of teeth (71.7%) and prolonged retention of deciduous teeth (31.7%). 6. The impaction of the teeth occurred in anterior portion of maxilla (44.2%) amd mandible (19.2%), but root resorption of the adjacent teeth were not seen. 7. The boundary to adjacent structure was well-defined , the lesions appear as radiopaque mass with radiolucent rim.

  18. Cervical spine motion: radiographic study

    International Nuclear Information System (INIS)

    Morgan, J.P.; Miyabayashi, T.; Choy, S.

    1986-01-01

    Knowledge of the acceptable range of motion of the cervical spine of the dog is used in the radiographic diagnosis of both developmental and degenerative diseases. A series of radiographs of mature Beagle dogs was used to identify motion within sagittal and transverse planes. Positioning of the dog's head and neck was standardized, using a restraining board, and mimicked those thought to be of value in diagnostic radiology. The range of motion was greatest between C2 and C5. Reports of severe disk degeneration in the cervical spine of the Beagle describe the most severely involved disks to be C4 through C7. Thus, a high range of motion between vertebral segments does not seem to be the cause for the severe degenerative disk disease. Dorsoventral slippage between vertebral segments was seen, but was not accurately measured. Wedging of disks was clearly identified. At the atlantoaxio-occipital region, there was a high degree of motion within the sagittal plane at the atlantoaxial and atlanto-occipital joints; the measurement can be a guideline in the radiographic diagnosis of instability due to developmental anomalies in this region. Lateral motion within the transverse plane was detected at the 2 joints; however, motion was minimal, and the measurements seemed to be less accurate because of rotation of the cervical spine. Height of the vertebral canal was consistently noted to be greater at the caudal orifice, giving some warning to the possibility of overdiagnosis in suspected instances of cervical spondylopathy

  19. New view on the initial development site and radiographic classification system of osteoarthritis of the knee based on radiographic analysis.

    Science.gov (United States)

    Moon, Ki-Ho

    2012-12-01

    Radiographic pathology of severe osteoarthritis of the knee (OAK) such as severe osteophyte at tibial spine (TS), compartment narrowing, marginal osteophyte, and subchondral sclerosis is well known. Kellgren-Lawrence grading system, which is widely used to diagnose OAK, describes narrowing-marginal osteophyte in 4-grades but uses osteophyte at TS only as evidence of OAK without detailed-grading. However, kinematically the knee employs medial TS as an axis while medial and lateral compartments carry the load, suggesting that early OAK would occur sooner at TS than at compartment. Then, Kellgren-Lawrence system may be inadequate to diagnose early-stage OAK manifested as a subtle osteophyte at TS without narrowing-marginal osteophyte. This undiagnosed-OAK will deteriorate becoming a contributing factor in an increasing incidence of OAK. This study developed a radiographic OAK-marker based on both osteophyte at TS and compartment narrowing-marginal osteophyte and graded as normal, mild, moderate, and severe. With this marker, both knee radiographs of 1,728 patients with knee pain were analyzed. Among 611 early-stage mild OAK, 562 or 92% started at TS and 49 or 8% at compartment. It suggests the initial development site of OAK, helping develop new site-specific radiographic classification system of OAK accurately to diagnose all severity of OAK at early, intermediate, or late-stage. It showed that Kellgren-Lawrence system missed 92.0% of early-stage mild OAK from diagnosis. A subtle osteophyte at TS is the earliest radiographic sign of OAK. A new radiographic classification system of OAK was suggested for accurate diagnosis of all OAK in severity and at stage.

  20. An atlas of normal skeletal scintigraphy

    International Nuclear Information System (INIS)

    Flanagan, J.J.; Maisey, M.N.

    1985-01-01

    This atlas was compiled to provide the neophyte as well as the experienced radiologist and the nuclear medicine physician with a reference on normal skeletal scintigraphy as an aid in distinguishing normal variations in skeletal uptake from abnormal findings. Each skeletal scintigraph is labeled, and utilizing an identical scale, a relevant skeletal photograph and radiograph are placed adjacent to the scintigraph

  1. Relation of N-Terminal Pro-B-Type Natriuretic Peptide and Left Ventricular Diastolic Function to Exercise Tolerance in Patients With Significant Valvular Heart Disease and Normal Left Ventricular Systolic Function.

    Science.gov (United States)

    Hwang, Ji-Won; Park, Sung-Ji; Cho, Eun Jeong; Kim, Eun Kyoung; Lee, Ga Yeon; Chang, Sung-A; Choi, Jin-Oh; Lee, Sang-Chol; Park, Seung Woo

    2017-06-01

    An association between N-terminal prohormone brain natriuretic peptide (NT-proBNP) and exercise tolerance in patients with valvular heart disease (VHD) has been suggested; however, there are few data available regarding this relation. The aim of this study is to evaluate the correlation between exercise tolerance and NT-proBNP in patients with asymptomatic or mildly symptomatic significant VHD and normal left ventricular ejection fraction (LV EF). A total of 96 patients with asymptomatic or mildly symptomatic VHD and normal LV EF (≥50%) underwent cardiopulmonary exercise echocardiography. NT-proBNP levels were determined at baseline and after exercise in 3 hours. Patients were divided in 2 groups based on lower (left atrial volume index before exercise, right ventricular systolic pressure before exercise, E velocity after exercise, and E/e' ratio after exercise varied significantly. In addition, peak VO 2 was inversely related to NT-proBNP before (r = -0.352, p left atrial volume index, E/e' ratio, and right ventricular systolic pressure before and after exercise. NT-proBNP after exercise was also directly related to the same parameters. NT-proBNP levels both before and after exercise were higher in the group with lower exercise tolerance. In conclusion, through the correlation among exercise tolerance, NT-proBNP, and parameters of diastolic dysfunction, we demonstrated that diastolic dysfunction and NT-proBNP could predict exercise tolerance in patients with significant VHD and normal LV EF. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Chest radiographic findings of tsutsugamushi disease and murine typhus in Chunchon

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heung Chul; Han, Tae Giun; Jang, Won Ho; Hwang, Woo Chul; Park, Man Soo; Lee, Myoung Gu; Kim, Yoon Won [School of Medicine, Hallym University, Chuncheon (Korea, Republic of); Park, Choong Ki [College of Medicine, Hanyang University, Guri (Korea, Republic of)

    1995-06-15

    To evaluate the chest radiographic findings of rickettsial disease including murine typhus and tsutsugamushi disease in Chunchon. Chest radiographic films of 81 cases diagnosed as rickettsial disease(55 cases of tsutsugamushi disease, 26 cases of murine typhus) by immunofluorescence test were retrospectively analyzed. Main serotypes of Rickettsia tsutsugamushi were Gilliam and Karp. Incidence rate of tsutsugamushi disease was 2.1 times greater than that of murine typhus. Chest radiographs were abnormal in 63.6% of tsutsugamushi disease, and in 30.8% of murine typhus. Radiographic findings were Kerly's B line, reticulonodular densities, hilar enlargement, pleural effusion, and splenomegaly in both entities, but pulmonary consolidation was only found in tsutsugamushi disease. The patients with the abnormal radiographic findings were statistically well correlated with cardiomegaly ({rho} < 0.01) and azygos engorgement ({rho} < 0.05), as compared to the patients with normal radiographic findings. Radiographic findings of both murine typhus and tsutsugamushi disease were interstitial pattern. But the chest radiographs in patients with tsutsugamushi disease showed more severe pattern with higher rate of abnormality.

  3. Chest radiographic findings of tsutsugamushi disease and murine typhus in Chunchon

    International Nuclear Information System (INIS)

    Kim, Heung Chul; Han, Tae Giun; Jang, Won Ho; Hwang, Woo Chul; Park, Man Soo; Lee, Myoung Gu; Kim, Yoon Won; Park, Choong Ki

    1995-01-01

    To evaluate the chest radiographic findings of rickettsial disease including murine typhus and tsutsugamushi disease in Chunchon. Chest radiographic films of 81 cases diagnosed as rickettsial disease(55 cases of tsutsugamushi disease, 26 cases of murine typhus) by immunofluorescence test were retrospectively analyzed. Main serotypes of Rickettsia tsutsugamushi were Gilliam and Karp. Incidence rate of tsutsugamushi disease was 2.1 times greater than that of murine typhus. Chest radiographs were abnormal in 63.6% of tsutsugamushi disease, and in 30.8% of murine typhus. Radiographic findings were Kerly's B line, reticulonodular densities, hilar enlargement, pleural effusion, and splenomegaly in both entities, but pulmonary consolidation was only found in tsutsugamushi disease. The patients with the abnormal radiographic findings were statistically well correlated with cardiomegaly (ρ < 0.01) and azygos engorgement (ρ < 0.05), as compared to the patients with normal radiographic findings. Radiographic findings of both murine typhus and tsutsugamushi disease were interstitial pattern. But the chest radiographs in patients with tsutsugamushi disease showed more severe pattern with higher rate of abnormality

  4. Chest radiographic findings of tsutsugamushi disease and murine typhus in Chunchon

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heung Chul; Han, Tae Giun; Jang, Won Ho; Hwang, Woo Chul; Park, Man Soo; Lee, Myoung Gu; Kim, Yoon Won [School of Medicine, Hallym University, Chuncheon (Korea, Republic of); Park, Choong Ki [College of Medicine, Hanyang University, Guri (Korea, Republic of)

    1995-06-15

    To evaluate the chest radiographic findings of rickettsial disease including murine typhus and tsutsugamushi disease in Chunchon. Chest radiographic films of 81 cases diagnosed as rickettsial disease(55 cases of tsutsugamushi disease, 26 cases of murine typhus) by immunofluorescence test were retrospectively analyzed. Main serotypes of Rickettsia tsutsugamushi were Gilliam and Karp. Incidence rate of tsutsugamushi disease was 2.1 times greater than that of murine typhus. Chest radiographs were abnormal in 63.6% of tsutsugamushi disease, and in 30.8% of murine typhus. Radiographic findings were Kerly's B line, reticulonodular densities, hilar enlargement, pleural effusion, and splenomegaly in both entities, but pulmonary consolidation was only found in tsutsugamushi disease. The patients with the abnormal radiographic findings were statistically well correlated with cardiomegaly ({rho} < 0.01) and azygos engorgement ({rho} < 0.05), as compared to the patients with normal radiographic findings. Radiographic findings of both murine typhus and tsutsugamushi disease were interstitial pattern. But the chest radiographs in patients with tsutsugamushi disease showed more severe pattern with higher rate of abnormality.

  5. Radiographic parameters of the hip joint from birth to adolescence

    Energy Technology Data Exchange (ETDEWEB)

    Than, P.; Kranicz, J.; Bellyei, A. [Dept. of Orthopaedics, Univ. of Pecs, Medical Faculty, Ifjusag utja (Hungary); Sillinger, T. [Dept. of Orthopaedics, Szt Gyorgy County Hospital, Szekesfehervar (Hungary)

    2004-03-01

    Background: Various qualitative and quantitative radiological geometrical parameters can be of great help when assessing dysplasia of the hip joint and in understanding developmental processes of the infant hip. There are few data on the normal values of the hip joint at different ages. Objective: To perform radiographic measurements on hip joints considered to be anatomically normal and to provide data for each age group, thus describing features of the radiographic development of the hip. Materials and methods: Radiographs were examined from 355 children (age 0-16 years) undergoing examination for scoliosis (long film), urography or plain abdominal radiography. Qualitative and quantitative signs were observed and measured, focusing on the Hilgenreiner, Wiberg and Idelberger angles and the decentric distance. Results: Before the age of 9 years measurable data from neighbouring age groups differed significantly, indicating typical radiological changes of the joint. For the same age range, qualitative changes could also be observed. After 9 years of age, radiological development of the normal hip joint during childhood is much slower. (orig.)

  6. Diagnostic value of chest radiographs in bedridden patients suspected of having pneumonia.

    Science.gov (United States)

    Esayag, Yaacov; Nikitin, Irina; Bar-Ziv, Jacob; Cytter, Ruth; Hadas-Halpern, Irith; Zalut, Todd; Yinnon, Amos M

    2010-01-01

    To assess the diagnostic value of the chest radiograph for the diagnosis of pneumonia in bedridden patients, using non-contrast-enhanced high-resolution chest computed tomography (CT) as the gold standard. We prospectively evaluated bedridden patients hospitalized with moderate to high clinical probability of pneumonia. Chest radiographs were interpreted in a blinded fashion by 3 observers and classified as definite, normal, or uncertain for pneumonia. Chest CT was obtained within 12 hours of chest radiograph. We applied Bayesian analysis to assess the accuracy of chest radiograph in the diagnosis of pneumonia. In a 5-month period, 58 patients were evaluated, 31 (53%) were female. Their chest radiographs were interpreted as negative, uncertain, or positive for pneumonia in 31 (53%), 15 (26%), and 12 (21%) patients, respectively, while CT confirmed pneumonia in 11 (35%), 10 (67%), and in 10 (83%). The sensitivity of the chest radiograph to diagnose pneumonia was 65%, the specificity was 93%, the positive and negative predictive values were, respectively, 83% and 65%, while the overall accuracy was 69% (95% confidence interval, 50%-79%). In bedridden patients with suspected pneumonia, a normal chest radiograph does not rule out the diagnosis, hence, a chest CT scan might provide valuable diagnostic information. Copyright 2010 Elsevier Inc. All rights reserved.

  7. Radiographic appearance of the middle ear after ventral bulla osteotomy in five dogs with otitis media

    International Nuclear Information System (INIS)

    Holt, D.E.; Walker, L.

    1997-01-01

    Radiographs of the middle ear were made in five dogs 60 to 78 months after ventral bulla osteotomy was performed to treat otitis media. The clinical results of surgery were considered satisfactory in four dogs and unsatisfactory in one. In 4 dogs with satisfactory results, radiographs demonstrated complete reformation of the bulla in 3 operated middle ears (3 dogs), with partial bulla reformation in the three middle ears (3 dogs). Radiographs in one dog with unsatisfactory results showed complete bulla reformation with no increase in lumen opacity. The proliferative bony response obliterating the middle ear previously reported in normal dogs after ventral bulla osteotomy was not seen in any of these patients

  8. The radiographic localization of unerupted maxillary incisors and supernumeraries

    International Nuclear Information System (INIS)

    Kim, Jae Duk; Lee, Chang Yul; You, Choong Hyun

    2003-01-01

    To evaluate the use of the vertical tube shift from a panoramic film and a periapical film to localize unerupted maxillary incisors and supernumeraries. The total of 103 displaced maxillary incisors or embedded supernumeraries were examined in this study. The vertical tube shift technique with panoramic and periapical radiography by normal projection taken and compared to localize the position of the embedded maxillary incisors or supernumeraries by a radiologist and 5 general dentists. The gold standard used for the radiographic comparisons was the true position of the embedded tooth as confirmed by horizontal tube shift technique using three periapical radiographs. The general dentist examiners were instructed on the use of the modified acronym 'SLDOBU' by the radiologist as it pertains to panoramic radiographs as the principle of vertical tube shift. All of the embedded maxillary incisors and supernumeraries were successfully located using the vertical tube shift from a panoramic and a maxillary anterior periapical radiograph by the radiologist and 5 general dentists. The use of a panoramic film with a periapical film combination for a vertical tube shift can be useful to localize unerupted maxillary incisors and supernumeraries.

  9. Estimation of lung volumes from chest radiographs using shape information

    International Nuclear Information System (INIS)

    Pierce, R.J.; Brown, D.J.; Holmes, M.; Cumming, G.; Denison, D.M.

    1979-01-01

    The cross-sectional shapes of the chest and its contained structures were assessed in post-mortem anatomical sections and from computerised tomographic scans in living subjects. These shapes are described by simple equations that can be used to increase the accuracy of measuring lung volumes from chest radiographs. Radiographic estimates of total lung capacity, using the equations, were compared with plethysmographic and single-breath helium dilution measurements in 35 normal subjects. After correction for posture effects the radiographic estimates of TLC, which measure the displacement volume of the lung, exceeded the plethysmographic estimates of contained gas volume by a mean of 720 ml, which was taken as the volume of tissue, blood, and water in the lungs. The single-breath dilution estimates of TLC fell short of the plethysmographic values by a mean of 480 ml, taken as the volume of contained gas that was inaccessible to helium in 10 seconds. The tomographic studies suggested that the radiographic technique of measuring lung displacement volumes has an accuracy of +- 210 ml. The method is rapid and simple to use and the intra- and inter-observer variabilities of <1% and <5% respectively. (author)

  10. Radiographic appearances in Crohn's disease. I. Accuracy of radiographic methods

    Energy Technology Data Exchange (ETDEWEB)

    Hildell, J; Lindstroem, C; Wenckert, A [Departments of Diagnostic Radiology, Pathology and Surgery, Malmoe Allmaenna Sjukhus, Malmoe, Sweden

    1979-01-01

    Preoperative films of 176 patients operated upon for Crohn's disease were reviewed and compared with microscopic findings in the resected specimens in order to assess the accuracy of the radiographic techniques used. It was found that a diagnosis of the presence and the extent of the disease was often dependent on the demonstration of minor mucosal ulcers and less marked submucosal edema. These lesions were not adequately demonstrated by any of the techniques used for small bowel examination, but were consistently revealed by the double-contrast technique used for examination of the colon.

  11. An evaluation of musculoskeletal discomfort experience by radiographers performing mammography

    International Nuclear Information System (INIS)

    Gale, A.G.; May, J.

    1997-01-01

    The aim of this study was to establish whether breast screening radiographers experience any problems of musculoskeletal discomfort, and if so the nature and extent of these problems. The study was then further extended to investigate and determine possible occupational, causal or contributory factors, and to suggest recommendations to help alleviate any discomfort. To investigate this problem five main approaches were undertaken. These consisted of; a national survey, an observational study, the comparison of the physical measurements of the mammography units with anthropometric data, a detailed task analysis, and a body mapping study. The national survey set out to determine if the nature and frequency of such problems were higher in mammography than in other areas of radiography or in the general population. Additionally, comparisons were made with non-radiographic staff working at the same breast screening centres. Video recordings of radiographers performing breast screening were also made and posture analysis performed on these data. A detailed task analysis was conducted to identify interaction points and possible problems between the radiographer and the equipment which she is required to use. Physical measurements of the mammography units were made and compared with anthropometric measurements and guidelines. The body mapping study measured the build up of discomfort throughout the working day on several different mammography units. The results from the survey questionnaire indicated that some breast screening radiographers do experience musculoskeletal problems, and that these are different in nature and prevalence from the musculoskeletal discomfort reported by the two control groups. The prevalence of back pain reported by radiographers undertaking mammography was higher than that present in the normal population. No comparison could be made with other body areas as data regarding other types of musculoskeletal discomfort in the general population are

  12. Do we really need radiographic assessment for the diagnosis of non-specific heel pain (calcaneal apophysitis) in children?

    International Nuclear Information System (INIS)

    Kose, Ozkan

    2010-01-01

    Non-specific heel pain (calcaneal apophysitis) is a common disorder, particularly in physically active growing children. Foot radiographs are usually obtained as part of the clinical evaluation in routine orthopaedic practice. However, there is still controversy about the specific findings on radiographs, and it is unclear what information is present on radiographs that may alter the diagnosis and management. The purpose of this study was to review a consecutive series of patients with the diagnosis of calcaneal apophysitis to assess the yield of routine radiographs of the foot. A prospective study was performed on 61 consecutive patients with a diagnosis of calcaneal apophysitis in a single-surgeon practice. Standard anteroposterior and lateral weight-bearing foot radiographs were obtained for each patient. Seventy-one sets of foot radiographs were reviewed to determine whether radiographs had an impact on diagnosis and management. Patients with antecedent trauma, penetrating injury, foot deformity, achilles tendonitis, bursitis and infections were excluded from the study. Seventy foot radiographs were considered to be normal. The radiographs changed the diagnosis in only one patient, in whom a simple bone cyst of the calcaneous was seen. Calcaneal apophysitis is a self-limiting disease, and patients can be treated conservatively. Neither the sclerosis nor the fragmentation of the apophysis could be used to establish the diagnosis of calcaneal apophysitis. Therefore, obtaining radiographs as an initial step in their evaluation does not seem to be justified. (orig.)

  13. Do we really need radiographic assessment for the diagnosis of non-specific heel pain (calcaneal apophysitis) in children?

    Energy Technology Data Exchange (ETDEWEB)

    Kose, Ozkan [Diyarbakir Education and Research Hospital, Orthopaedics and Traumatology Clinic, Diyarbakir (Turkey); Diclekent Bulvari, Ataslar Serhat Evleri, Diyarbakir (Turkey)

    2010-04-15

    Non-specific heel pain (calcaneal apophysitis) is a common disorder, particularly in physically active growing children. Foot radiographs are usually obtained as part of the clinical evaluation in routine orthopaedic practice. However, there is still controversy about the specific findings on radiographs, and it is unclear what information is present on radiographs that may alter the diagnosis and management. The purpose of this study was to review a consecutive series of patients with the diagnosis of calcaneal apophysitis to assess the yield of routine radiographs of the foot. A prospective study was performed on 61 consecutive patients with a diagnosis of calcaneal apophysitis in a single-surgeon practice. Standard anteroposterior and lateral weight-bearing foot radiographs were obtained for each patient. Seventy-one sets of foot radiographs were reviewed to determine whether radiographs had an impact on diagnosis and management. Patients with antecedent trauma, penetrating injury, foot deformity, achilles tendonitis, bursitis and infections were excluded from the study. Seventy foot radiographs were considered to be normal. The radiographs changed the diagnosis in only one patient, in whom a simple bone cyst of the calcaneous was seen. Calcaneal apophysitis is a self-limiting disease, and patients can be treated conservatively. Neither the sclerosis nor the fragmentation of the apophysis could be used to establish the diagnosis of calcaneal apophysitis. Therefore, obtaining radiographs as an initial step in their evaluation does not seem to be justified. (orig.)

  14. Radiographically visualized skeletal changes associated with mucopolysaccharidosis VI in cats

    International Nuclear Information System (INIS)

    Konde, L.J.; Thrall, M.A.; Gasper, P.; Dial, S.M.; McBiles, K.; Colgan, S.; Haskins, M.

    1987-01-01

    The radiographic skeletal form and structure of all cats with mucopolysaccharidosis VI is described. Common manifestations included epiphyseal dysplasia, generalized osteoporosis, abnormal nasal turbinate development, his subluxation, impaired development of skeletal growth, pectus excavatum, hyoid hypoplasia, aplasia, hypoplasia and fragmentation or abnormal ossification of the dens, and aplasia or hypoplasia of frontal and sphenoid sinuses. The skeletal measurements of two affected cats were compared with those of normal, sex-matched littermates, and the measurements of two affected female cats were compared with those of a normal male littermate

  15. Assessment of Radiographic Image Quality by Visual Examination of Neutron Radiographs of the Calibration Fuel Pin

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Up till now no reliable radiographic image quality standards exist for neutron radiography of nuclear reactor fuel. Under the Euratoro Neutron Radiography Working Group (NRWG) Test Program neutron radiographs were produced at different neutron radiography facilities within the European Community...... of a calibration fuel pin. The radiographs were made by the direct, transfer and tracketch methods using different film recording materials. These neutron radiographs of the calibration fuel pin were used for the assessement of radiographic image quality. This was done by visual examination of the radiographs...

  16. Combined heart-kidney transplantation after total artificial heart insertion.

    Science.gov (United States)

    Ruzza, A; Czer, L S C; Ihnken, K A; Sasevich, M; Trento, A; Ramzy, D; Esmailian, F; Moriguchi, J; Kobashigawa, J; Arabia, F

    2015-01-01

    We present the first single-center report of 2 consecutive cases of combined heart and kidney transplantation after insertion of a total artificial heart (TAH). Both patients had advanced heart failure and developed dialysis-dependent renal failure after implantation of the TAH. The 2 patients underwent successful heart and kidney transplantation, with restoration of normal heart and kidney function. On the basis of this limited experience, we consider TAH a safe and feasible option for bridging carefully selected patients with heart and kidney failure to combined heart and kidney transplantation. Recent FDA approval of the Freedom driver may allow outpatient management at substantial cost savings. The TAH, by virtue of its capability of providing pulsatile flow at 6 to 10 L/min, may be the mechanical circulatory support device most likely to recover patients with marginal renal function and advanced heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion on the substantiation of a health claim related to vitamin K2 and contribution to the normal function of the heart and blood vessels (ID 125, further assessment) pursuant to Article 13(1) of Regulation (EC) No 1924/2006

    DEFF Research Database (Denmark)

    Tetens, Inge

    Following a request from the European Commission, pursuant to Article 13 of Regulation (EC) No 1924/2006, the Panel on Dietetic Products, Nutrition and Allergies was asked to provide a scientific opinion on a health claim related to vitamin K2 and contribution to the normal function of the heart...... and blood vessels. The food constituent that is the subject of the claim, vitamin K2, is sufficiently characterised. The claimed effect, contribution to the normal function of the heart and blood vessels, is a beneficial physiological effect. The proposed target population is the general population......, that the results of two prospective cohort studies are in conflict regarding the risk of coronary heart disease associated with vitamin K2 intakes, that high intakes of vitamin K2 were associated with a significantly lower degree of aortic calcification in one prospective cohort study after adjustment...

  18. An evaluation of musculoskeletal discomfort experience by radiographers performing mammography

    Energy Technology Data Exchange (ETDEWEB)

    Gale, A.G.; May, J

    1997-10-01

    The aim of this study was to establish whether breast screening radiographers experience any problems of musculoskeletal discomfort, and if so the nature and extent of these problems. The study was then further extended to investigate and determine possible occupational, causal or contributory factors, and to suggest recommendations to help alleviate any discomfort. To investigate this problem five main approaches were undertaken. These consisted of; a national survey, an observational study, the comparison of the physical measurements of the mammography units with anthropometric data, a detailed task analysis, and a body mapping study. The national survey set out to determine if the nature and frequency of such problems were higher in mammography than in other areas of radiography or in the general population. Additionally, comparisons were made with non-radiographic staff working at the same breast screening centres. Video recordings of radiographers performing breast screening were also made and posture analysis performed on these data. A detailed task analysis was conducted to identify interaction points and possible problems between the radiographer and the equipment which she is required to use. Physical measurements of the mammography units were made and compared with anthropometric measurements and guidelines. The body mapping study measured the build up of discomfort throughout the working day on several different mammography units. The results from the survey questionnaire indicated that some breast screening radiographers do experience musculoskeletal problems, and that these are different in nature and prevalence from the musculoskeletal discomfort reported by the two control groups. The prevalence of back pain reported by radiographers undertaking mammography was higher than that present in the normal population. No comparison could be made with other body areas as data regarding other types of musculoskeletal discomfort in the general population are

  19. Heart Diseases

    Science.gov (United States)

    ... you're like most people, you think that heart disease is a problem for others. But heart disease is the number one killer in the ... of disability. There are many different forms of heart disease. The most common cause of heart disease ...

  20. Heart Transplantation

    Science.gov (United States)

    A heart transplant removes a damaged or diseased heart and replaces it with a healthy one. The healthy heart comes from a donor who has died. It is the last resort for people with heart failure when all other treatments have failed. The ...

  1. NEUROTICISM PROFILE IN CORONARY HEART DISEASE

    OpenAIRE

    Bhargava, S. C.; Sharma, S. N.; Agarwal, B. V.

    1980-01-01

    SUMMARY Thirty seven cases of coronary heart disease and 30 normal healthy controls were administered Hindi version of MHQ. The coronary heart disease patients scored significantly higher on total neuroticism, free-floating anxiety and somatic anxiety subscales of MHQ.

  2. Total elbow arthroplasty: a radiographic outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xue Susan [University of Washington, Department of Radiology, Box 357115, Seattle, WA (United States); Petscavage-Thomas, Jonelle M. [Penn State Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Ha, Alice S. [University of Washington, Department of Radiology, Box 354755, Seattle, WA (United States)

    2016-06-15

    Total elbow arthroplasty (TEA) is becoming a popular alternative to arthrodesis for patients with end-stage elbow arthrosis and comminuted distal humeral fractures. Prior outcome studies have primarily focused on surgical findings. Our purpose is to determine the radiographic outcome of TEA and to correlate with clinical symptoms such as pain. This is an IRB-approved retrospective review from 2005 to 2015 of all patients with semiconstrained TEA. All available elbow radiographs and clinical data were reviewed. Data analysis included descriptive statistics and Kaplan-Meier survival curves for radiographic and clinical survival. A total of 104 total elbow arthroplasties in 102 patients were reviewed; 75 % were in women and the mean patient age was 63.1 years. Mean radiographic follow-up was 826 days with average of four radiographs per patient. Seventy TEAs (67 %) developed radiographic complications, including heterotopic ossification (48 %), perihardware lucency (27 %), periprosthetic fracture (23 %), hardware subluxation/dislocation (7 %), polyethylene wear (3 %), and hardware fracture/dislodgement (3 %); 56 patients (55 %) developed symptoms of elbow pain or instability and 30 patients (30 %) underwent at least one reoperation. In patients with radiographic complications, 66 % developed elbow pain, compared to 19 % of patients with no radiologic complications (p = 0.001). Of the patients with radiographic complications, 39 % had at least one additional surgery compared to 0 % of patients without radiographic complications (p = 0.056). Radiographic complications are common in patients after total elbow arthroplasty. There is a strong positive association between post-operative radiographic findings and clinical outcome. Knowledge of common postoperative radiographic findings is important for the practicing radiologist. (orig.)

  3. A radiographic analysis of implant component misfit.

    LENUS (Irish Health Repository)

    Sharkey, Seamus

    2011-07-01

    Radiographs are commonly used to assess the fit of implant components, but there is no clear agreement on the amount of misfit that can be detected by this method. This study investigated the effect of gap size and the relative angle at which a radiograph was taken on the detection of component misfit. Different types of implant connections (internal or external) and radiographic modalities (film or digital) were assessed.

  4. Radiation protection - radiographer's role and responsibilities

    International Nuclear Information System (INIS)

    Popli, P.K.

    2002-01-01

    Ever since discovery of x-rays, radiographers has been the prime user of radiation. With the passage of time, the harmful effects of radiation were detected. Some of radiographers, radiologists and public were affected by radiation, but today with enough knowledge of radiation, the prime responsibility of radiation protection lies with the radiographers only. The radiologist and physicist are also associated with radiation protection to some extent

  5. The use and abuse of radiographic grids

    International Nuclear Information System (INIS)

    Brough, P.D.

    1981-01-01

    It is generally accepted that scattered radiation degrades the quality of the radiographic image. When this problem occurs, a radiographic grid may be applied which necessitates an increase in exposure. Investigations are reported in the following areas: reasons for the introduction of a radiographic grid; the ratio between kilovoltage and grid ratio; techniques resulting in higher contrast and resolution at low patient dose and the abuse of grids

  6. Measure by image analysis of industrial radiographs

    International Nuclear Information System (INIS)

    Brillault, B.

    1988-01-01

    A digital radiographic picture processing system for non destructive testing intends to provide the expert with computer tool, to precisely quantify radiographic images. The author describes the main problems, from the image formation to its characterization. She also insists on the necessity to define a precise process in order to automatize the system. Some examples illustrate the efficiency of digital processing for radiographic images [fr

  7. Radiographic features of periapical cysts and granulomas

    OpenAIRE

    Zain, R. B.; Roswati, N.; Ismail, K.

    1989-01-01

    Many studies have been reported on radiographic lesion sizes of periapical lesions. However no studies have been reported on prevalences of subjective radiographic features in these lesions except for the early assumption that a periapical cyst usually exhibit a radiopaque cortex. This study is conducted to evaluate the prevalences of several subjective radiographic features of periapical cysts and granulomas in the hope to identify features that maybe suggestive of either diagnosis. The resu...

  8. Radiographic features of paediatric pneumocystis pneumonia - a historical perspective

    Energy Technology Data Exchange (ETDEWEB)

    Pitcher, R.D. [Division of Paediatric Radiology, Red Cross War Memorial Children' s Hospital, School of Child and Adolescent Health, University of Cape Town, Cape Town (South Africa)], E-mail: pitcher@iafrica.com; Zar, H.J. [Department of Paediatric Pulmonology, Red Cross War Memorial Children' s Hospital, School of Child and Adolescent Health, University of Cape Town, Cape Town (South Africa)

    2008-06-15

    Aim: To determine differences between the plain radiographic features of paediatric pneumocystis pneumonia (PCP) recorded before the emergence of human immunodeficiency virus (HIV) in 1982 and those documented in the HIV era. To establish differences in the radiographic features of PCP documented in HIV-infected children in developed and developing countries. Method: A Medline search of articles was conducted from 1950 to 2006, using the terms 'pneumocystis pneumonia in children' and 'chest radiographic features' or 'bilateral opacification' or 'lobar consolidation' or 'asymmetrical opacification' or 'pneumatocoeles' or 'cavities' or 'pneumothorax' or 'pneumomediastinum' or 'pleural effusion' or 'mediastinal adenopathy' or 'nodules' or 'normal chest radiography'. Appropriate articles were retrieved, radiological data extracted, reference lists examined and hand searches of referenced articles conducted. Results: Diffuse bilateral 'ground-glass' or alveolar pulmonary opacification, which may show some asymmetry, has been consistently documented as the commonest radiographic finding in childhood PCP throughout the period under review. The less common radiological features of PCP in children are similar to those in adults. In developed countries, PCP-related pulmonary air cysts have been reported at an earlier age in HIV-infected children, compared with uninfected children. PCP-related air cysts, pneumothorax, and pneumomediastinum have been reported in children in developed but not in developing countries. Conclusion: The radiological features of paediatric PCP documented before the HIV epidemic are similar to those recorded in the HIV era. Further study of the determinants of the uncommon radiographic features in children is warranted.

  9. Automating the radiographic NDT process

    International Nuclear Information System (INIS)

    Aman, J.K.

    1988-01-01

    Automation, the removal of the human element in inspection has not been generally applied to film radiographic NDT. The justification for automation is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 3x10 (to the power of nine) bits per 14x17. This is equivalent to 2200 computer floppy disks parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, a computer aided interpretation appears on the horizon. A unit which laser scans a 14x27 (inch) film in 6-8 seconds can digitize film in information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for film digital radiography system) is moving toward 50 micron (16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. (Author). 4 refs.; 21 figs

  10. Prognostic radiographic aspects of spondylolisthesis

    International Nuclear Information System (INIS)

    Saraste, H.; Brostroem, L.A.; Aparisi, T.

    1984-01-01

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films frompatients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping. (orig.)

  11. Prognostic radiographic aspects of spondylolisthesis

    Energy Technology Data Exchange (ETDEWEB)

    Saraste, H; Brostroem, L A; Aparisi, T

    1984-01-01

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films from patients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping.

  12. Computational simulation of radiographic film

    International Nuclear Information System (INIS)

    Goncalves, Elicardo A. de S.; Santos, Marcio H. dos; Anjos, Marcelino J.; Oliveira, Luis F. de

    2013-01-01

    The composition of a radiographic film gives its values of speed, spatial resolution and base density. The technical knowledge allows to predict how a film with a known composition works, and simulate how this film will work with changes in composition and exposure. In this paper, characterization of films composed by different emulsions was realized, in a way to know the characteristic curve, and to study how the format, organization and concentration of silver salt crystals set the radiographic film images.This work aims to increase an existing simulator, where parallel programming was used to simulate X-ray fluorescence processes. The setup of source and X-ray interactions with objects stills the same, and the detector constructed in this work was placed to form images. At first, considering the approach that the film is a square matrix where each element has a specific quantity of silver grains, that each grain fills a specific area, and that each interaction to radiation transforms a salt silver grain in to metallic silver grain (black grain), we have a blackening standard, and it should show how is the behavior of a optic density in a specific area of the film. Each matrix element has a degree of blackening, and it is proportional to the black grains area. (author)

  13. Stepped scanner radiographic imaging system

    International Nuclear Information System (INIS)

    Lapidus, S.N.

    1981-01-01

    The imaging system includes a radiographic camera, a bed for supporting a subject in view of the camera, and a display system. The camera provides X and Y coordinate signals of each radiographic event. The position of the bed relative to the camera is altered sequentially by drive means, between each of a sequence of images provided by the camera. The sequentially occurring images are presented on the display system, each image being positioned on the display in correspondence with the location of the bed relative to the camera. The coordinates of each image point presented on the display is equal to the sum of the respective X and Y coordinate signals from the camera with X and Y coordinate signals provided by a timer which controls the drive means and defines the location of the bed relative to the camera. The camera is electronically decoupled from the display by a gate during movement of the bed relative to the camera from one location to the next location to prevent any smearing effect within the composite image presented on the display. (author)

  14. Digital processing of radiographic images

    Science.gov (United States)

    Bond, A. D.; Ramapriyan, H. K.

    1973-01-01

    Some techniques are presented and the software documentation for the digital enhancement of radiographs. Both image handling and image processing operations are considered. The image handling operations dealt with are: (1) conversion of format of data from packed to unpacked and vice versa; (2) automatic extraction of image data arrays; (3) transposition and 90 deg rotations of large data arrays; (4) translation of data arrays for registration; and (5) reduction of the dimensions of data arrays by integral factors. Both the frequency and the spatial domain approaches are presented for the design and implementation of the image processing operation. It is shown that spatial domain recursive implementation of filters is much faster than nonrecursive implementations using fast fourier transforms (FFT) for the cases of interest in this work. The recursive implementation of a class of matched filters for enhancing image signal to noise ratio is described. Test patterns are used to illustrate the filtering operations. The application of the techniques to radiographic images of metallic structures is demonstrated through several examples.

  15. Gastric tumors on chest radiographs

    International Nuclear Information System (INIS)

    Tamura, Shozo; Kawanami, Takashi; Russell, W.J.

    1978-04-01

    Gastric neoplasms of three patients protruded into their gas-containing fornices and were first visualized on plain chest radiographs. Endoscopy and/or surgery confirmed these to be a polyp, a leiomyoma, and an adenocarcinoma. The polyp, 1.3 cm in diameter, was the smallest of these three, but smaller lesions may be detectable under suitable conditions. Adequate technique and positioning, sufficiently large lesions in the upper portion of the stomach, a central beam tangential to the tumor, sufficient gas in the stomach, and careful scrutiny by the observer are required. Lesions may be more readily visualized during chest radiography when oral sodium bicarbonate is used to distend the stomach. In chest radiography, exposure limited to the lung fields has been advocated for economy and dose reduction. However, too small an exposure field may result in loss of information potentially beneficial to the patient. Using the smaller of two popular film sizes (35 x 43 cm and 35 x 35 cm), the saving in surface and bone marrow doses is negligible, and the saving in gonad dose may be nil over that when shielding is used. The interest of the observer may be absorbed by a concomitant cardiac or pulmonary lesion. Careful scrutiny of the entire radiograph is therefore essential. (author)

  16. Radiographic localization of unerupted mandibular anterior teeth.

    Science.gov (United States)

    Jacobs, S G

    2000-10-01

    The parallax method and the use of 2 radiographs taken at right angles to each other are the 2 methods generally used to accurately localize teeth. For the parallax method, the combination of a rotational panoramic radiograph with an occlusal radiograph is recommended. This combination involves a vertical x-ray tube shift. Three case reports are presented that illustrate: (1) how this combination can accurately localize unerupted mandibular anterior teeth, (2) how a deceptive appearance of the labiolingual position of the unerupted tooth can be produced in an occlusal radiograph, (3) how increasing the vertical angle of the tube for the occlusal radiograph makes the tube shift easier to discern, (4) why occlusal radiographs are preferable to periapical radiographs for tube shifts, and (5) how localization can also be carried out with 2 radiographs at right angles to each other, one of which is an occlusal radiograph taken with the x-ray tube directed along the long axis of the reference tooth.

  17. Radiographic examination for successful dental implant

    International Nuclear Information System (INIS)

    Lee, Sam Sun; Choi, Soon Chul

    2005-01-01

    Recently implant has become an important field in dental clinic. Radiographic examination of pre- and post-operation is essential for successful treatment. Clinicians should have knowledge about the purpose of the radiographic examination, suitable imaging modality for the cases, anatomic landmarks of tooth and jaw bone, advantage and limitation of panoramic radiographic examination for implant, principle and interpretation of cross-sectional imaging, bone mineral density, post-operative radiographic examination. This paper will be helpful to get above information for dentists who want to do dental implant successfully.

  18. Reference Neutron Radiographs of Nuclear Reactor Fuel

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Reference neutron radiographs of nuclear reactor fuel were produced by the Euraton Neutron Radiography Working Group and published in 1984 by the Reidel Publishing Company. In this collection a classification is given of the various neutron radiographic findings, that can occur in different parts...... of pelletized, annular and vibro-conpacted nuclear fuel pins. Those parts of the pins are shown where changes of appearance differ from those for the parts as fabricated. Also radiographs of those as fabricated parts are included. The collection contains 158 neutron radiographs, reproduced on photographic paper...

  19. Radiographic anatomy and pathology of the child's airway

    International Nuclear Information System (INIS)

    Gay, B.B. Jr.

    1987-01-01

    The laryngotracheal airway has been considered the ''bottle-neck'' of the lungs. Any compromise of this already rather small pathway can easily result in a life-threatening situation. Rapid, accurate diagnosis is essential for proper clinical management of a compromised airway. Radiologic studies play a major role in the clinical investigation of patients with serious airway problems. There are notable differences between the anatomy of the upper airway of the adult and that of the young child or infant. In the infant, however, some differences in the radiographic patterns must be kept in mind. In the first 6 months of life, the adenoid shadow is not well defined and is normally absent until 1 month of age. During swallowing there is a lack of air in the pharynx with elevation of the larynx. Air may be seen in the cervical esophagus. All of these physiologic variations must be considered when interpreting radiographs of the neck in the young child

  20. Radiographically Occult and Subtle Fractures: A Pictorial Review

    International Nuclear Information System (INIS)

    Jarraya, M.; Hayashi, D.; Roemer, F.W.; Crema, M.D.; Conlin, J.; Marra, M.D.; Guermazi, A.; Roemer, F.W.; Crema, M.D.; Diaz, L.; Conlin, J.; Jomaah, N.

    2013-01-01

    Radiographically occult and subtle fractures are a diagnostic challenge. They may be divided into (1) high energy trauma fracture, (2) fatigue fracture from cyclical and sustained mechanical stress, and (3) insufficiency fracture occurring in weakened bone (e.g., in osteoporosis and post radiotherapy). Independently of the cause, the initial radiographic examination can be negative either because the findings seem normal or are too subtle. Early detection of these fractures is crucial to explain the patients symptoms and prevent further complications. Advanced imaging tools such as computed tomography, magnetic resonance imaging, and scintigraphy are highly valuable in this context. Our aim is to raise the awareness of radiologists and clinicians in these cases by presenting illustrative cases and a discussion of the relevant literature.

  1. Arthroscopic partial lateral meniscectomy in an otherwise normal knee

    DEFF Research Database (Denmark)

    Scheller, G; Sobau, C; Bülow, J U

    2001-01-01

    To determine the clinical, functional, and radiographic long-term results of patients who underwent arthroscopic partial lateral meniscectomy in an otherwise normal knee. Type of Study: This was a retrospective case-control study....

  2. Radiographer-led discharge in accident and emergency - The results of a pilot project

    International Nuclear Information System (INIS)

    Snaith, Beverly A.

    2007-01-01

    Introduction: The radiographers role in trauma has been traditionally limited to image acquisition, but has evolved to include responsibility for image interpretation. The contribution to ongoing patient management has been limited, despite pressure on A and E systems to decrease any potential delays. Background: Three experienced reporting radiographers were trained to discharge patients with a normal radiology report or refer to A and E for further management, following a documented management plan by the examining clinician in A and E. Discharge included advice on the acute management of soft tissue injuries including analgesia and exercise. Methodology: Over a 4-month period in early 2004 all patients whose examinations received a report at the time of attendance (hot report) were included and data were collected in relation to those who were discharged including journey times and further A and E attendances. Data were also collected regarding patients recalled to the A and E department due to misinterpretation of radiographs during the study period. Results: The radiographers hot reported 1760 examinations, discharging 88 (5%) and referring a further 26 (2%) directly for treatment. The number of patients recalled due to misinterpretation of the radiographs was decreased by 52% when compared with the previous 3 years data. Conclusion: Radiographers can safely extend their roles outside of the radiology department and contribute to the management of patients whilst decreasing risk of radiographic misinterpretation by A and E

  3. Diagnostic errors in interpretation of pediatric musculoskeletal radiographs at common injury sites

    International Nuclear Information System (INIS)

    Bisset, George S.; Crowe, James

    2014-01-01

    Extremity pain represents one of the most common reasons for obtaining conventional radiographs in childhood. Despite the frequency of these examinations little is known about the incidence of diagnostic errors by interpreting pediatric radiologists. The purpose of this study was to develop a standard error rate of pediatric radiologists by double-reading of extremity radiographs (elbow, wrists, knees and ankles) in children presenting with a history of trauma or pain. During a 6-month period all major extremity radiographs (excluding digits) obtained at a large pediatric referral hospital for evaluation of pain or trauma were reviewed by two senior pediatric radiologists and compared to the official interpretation. All radiographs were interpreted initially by a board-certified pediatric radiologist with a Certificate of Added Qualification (CAQ). We reviewed 3,865 radiographic series in children and young adults 2-20 years of age. We tabulated misses and overcalls. We did not assess the clinical significance of the errors. There were 61 miss errors and 44 overcalls in 1,235 abnormal cases and 2,630 normal cases, for a 1.6% miss rate and a 1.1% overcall rate. Misses and overcalls were most common in the ankle. Interpretive errors by pediatric radiologists reviewing certain musculoskeletal radiographs are relatively infrequent. Diagnostic errors in the form of a miss or overcall occurred in 2.7% of the radiographs. (orig.)

  4. An audit of hip radiographs performed for general practitioners

    International Nuclear Information System (INIS)

    Bhatt, Raj; Rajesh, Arumugam; Morgan, Bruno; Finlay, David

    2001-01-01

    AIM: We carried out a prospective study of the GP referrals for hip radiographs to find out the proportion of radiographs falling within the RCR guidelines and to ascertain the reasons for not following the guidelines. MATERIALS AND METHODS: One thousand two hundred and fifty six consecutive hip radiographs were performed for GPs over a 12-month period. Questionnaires were sent to GPs for 873 referrals during an audit period of 18 months Four hundred and fifty three questionnaires were returned with adequate information. The proportion of change in management between the patients falling within the guidelines and those outside the guidelines was compared using Fisher's Exact Test (SPSS Package Version 9) and the corresponding 95% confidence interval (CI) was calculated. RESULTS: Only 194 (43%) of the 453 referrals were within RCR guidelines and 259 (57%) were outside guidelines. In the group where RCR guidelines were followed, 60% were normal, 34% had degenerative changes and 6% other diagnoses. The radiological reports changed management in 44%. In the group where guidelines were not followed 76% were normal, 18% had degenerative changes and 6% other diagnoses. The radiological reports changed management in 37%. There was no evidence of difference in the change in management between these two groups. Twenty per cent of the radiographs showed abnormalities other than hip changes. Of these, only 17% were abnormalities other than degenerative changes and considered significant. CONCLUSIONS: This audit does not reveal why the majority of the requests fell outside guidelines. This may be due to lack of awareness amongst GPs about guidelines, patient pressure, medico-legal problems and the need for reassurance. However, the audit does not show any evidence that following guidelines would increase efficiency of referral. Bhatt R. et al. (2001)

  5. Validation of the plain chest radiograph for epidemiologic studies of airflow obstruction

    International Nuclear Information System (INIS)

    Musk, A.W.

    1982-01-01

    The chest radiographs of 125 industrial workers from rural New South Wales were examined for overinflated lungs, with and without attenuated midzonal vessels. Although the mean values of a comprehensive range of pulmonary function tests in the whole group were within normal limits, the nine subjects whose radiographs showed overinflated lungs and attenuated vessels had significantly impaired pulmonary function in comparison with 85 subjects with normal radiographs. The mean values for these nine subjects, expressed as a percentage of the mean value for subjects with normal radiographs, were: forced expiratory volume in 1 second, 75%; total lung capacity, 107%; residual volume, 143%; transpulmonary pressure at maximum inspiration, 60%; static deflation compliance, 158%; lung volume at transpulmonary pressure 10 cm H 2 O, 132%; transfer factor, 79%; and transfer factor/alveolar volume, 77%. Similar results were obtained by a second observer. Those subjects with overinflation but no vascular attenuation had significantly larger mean values for vital capacity and alveolar volume but no significant difference in total lung capacity or other tests of the mechanical properties of the lungs. Agreement on the presence of a positive sign between the two observers expressed as a percentage of those considered positive by either was 81% for overinflation and 62% for attenuated midzonal vessels. The results indicate that in groups of subjects with normal-average values of pulmonary function, the plain chest radiograph may provide information concerning pulmonary structure that is reflected in tests of function

  6. Prototype system for enhancement of frontal chest radiographs using eigenimage processing

    International Nuclear Information System (INIS)

    Butler, A.; Bones, P.; Hurrell, M.

    2008-01-01

    A prototype system is described for enhancement of radiographic images in the eigen domain. The images chosen to enhance are frontal chest radiographs. This class of images has been chosen because it is both a clinically important examination and an example of the high-resolution images used within radiology. The enhancement method is based on principal components analysis, a multivariate statistical technique first used within image processing for face recognition. The method requires a training set of normal images to identify normal patterns of variance. The enhancement process then removes these normal patterns of variance, often increasing the relative intensity of pathologies. Enhanced images presented in this paper include a range of common pathologies found on chest radiographs. Details of implementation, computing expense and possible applications within radiology are discussed.

  7. A radiographic study of nasopalatine duct cysts

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Chan Duck; Hwang, Eui Hwan; Lee, Sang Rae [Dept. of Oral Radiology, College of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    1993-02-15

    The purpose of this study was to evaluate the clinical and radiographic features of 35 cases of nasopalatine duct cyst by means of the analysis of periapical and/or occlusal radiograms in 35 persons visited the Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University and Chonbuk National University. The obtained results were as follows: 1. The incidence of nasopalatine duct cysts was higher in males (74.3%) than in females (25.7%). 2. The nasopalatine duct cysts were the most frequently occurred in the 4th decades (34.3%). The 6th and 7th decades (17.1%, 17.1%) were next in order to frequency followed by the 5th decades (14.3%), the 3rd decades (8.6%), the 2nd decades (5.7%), and 8th decades (2.9%). 3. In the signs and symptoms of nasopalatine duct cysts, 25.7% were swelling, 17.1% were swelling and tenderness, 20.0% were swelling and pain, and 37.2% were a symptom. 4. In the shape of nasopalatine duct cysts, 40.0% were round type, 48.6% 11.8% were heart type. 5. In symmetry of the nasopalatine duct cysts, 11.4% were 6-10 mm, 48.6% were 11-20 mm, 25.7% were 21-30 mm, and 14.3% were 31-40 mm. 6. In the periphery of nasopalatine duct cysts, 82.9% were distinct, 17.1% were relatively distinct. 7. In the change of root, 51.5% were intact, 17.1% were root divergence, 20.0% were root resorption, and 11.4% were root divergence and resorption.

  8. A radiographic study of nasopalatine duct cysts

    International Nuclear Information System (INIS)

    Jun, Chan Duck; Hwang, Eui Hwan; Lee, Sang Rae

    1993-01-01

    The purpose of this study was to evaluate the clinical and radiographic features of 35 cases of nasopalatine duct cyst by means of the analysis of periapical and/or occlusal radiograms in 35 persons visited the Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University and Chonbuk National University. The obtained results were as follows: 1. The incidence of nasopalatine duct cysts was higher in males (74.3%) than in females (25.7%). 2. The nasopalatine duct cysts were the most frequently occurred in the 4th decades (34.3%). The 6th and 7th decades (17.1%, 17.1%) were next in order to frequency followed by the 5th decades (14.3%), the 3rd decades (8.6%), the 2nd decades (5.7%), and 8th decades (2.9%). 3. In the signs and symptoms of nasopalatine duct cysts, 25.7% were swelling, 17.1% were swelling and tenderness, 20.0% were swelling and pain, and 37.2% were a symptom. 4. In the shape of nasopalatine duct cysts, 40.0% were round type, 48.6% 11.8% were heart type. 5. In symmetry of the nasopalatine duct cysts, 11.4% were 6-10 mm, 48.6% were 11-20 mm, 25.7% were 21-30 mm, and 14.3% were 31-40 mm. 6. In the periphery of nasopalatine duct cysts, 82.9% were distinct, 17.1% were relatively distinct. 7. In the change of root, 51.5% were intact, 17.1% were root divergence, 20.0% were root resorption, and 11.4% were root divergence and resorption.

  9. EFSA NDA Panel (EFSA Panel on Dietetic Products, Nutrition and Allergies), 2014. Scientific Opinion on the substantiation of a health claim related to “Lactobacillus plantarum TENSIA® in the semi-hard Edam-type „heart cheese‟ of Harmony™” and maintenance of normal blood pressure pursuant to Article

    DEFF Research Database (Denmark)

    Tetens, Inge

    on the scientific substantiation of a health claim related to “Lactobacillus plantarum TENSIA® in the semi-hard Edam-type “heart cheese” of Harmony™” and maintenance of normal blood pressure (BP). The food constituent L. plantarum TENSIA®, which is the subject of the health claim, is sufficiently characterised...... exert the claimed effect. The Panel concludes that a cause and effect relationship has not been established between the consumption of Lactobacillus plantarum TENSIA®in the semi-hard Edam-type “heart cheese” of Harmony™ and maintenance of normal blood pressure........ The Panel considers that the maintenance of normal blood pressure is a beneficial physiological effect. The applicant provided 47 references which did not address the effects of L. plantarum TENSIA® on BP. The Panel considers that no conclusions can be drawn from these references for the scientific...

  10. Single exposure simultaneous acquisition of digital and conventional radiographs utilizing unaltered dose

    International Nuclear Information System (INIS)

    Oestmann, J.W.; Greene, R.

    1988-01-01

    We describe the simultaneous acquisition of digital and conventional radiographs with a single standard radiographic exposure. A digitizable storage phosphor (ST Imaging Plate, Fuji) is sandwiched into a radiographic cassette (X-Omatic, Kodak) behind a conventional radiographic film-screen combination (Lanex medium screens, OC film, Kodak). The barium fluorohalide storage phosphor is digitized with a helium-neon laser scanner (TCR 201, Toshiba), and the conventional radiograph is processed in the standard fashion (M7B, Kodak). The storage phosphor is exposed by the 'wasted' radiation normally exiting the back of the film-screen combination (32% of the cassette entrance dose at 141 kVp). At a standard exposure (6.3 mAs), the conventional radiograph is of unaltered quality, and the digital image appears to have an adequate signal-to-noise ratio for chest studies despite the lower exposure dose. This technique produces twin images of identical spatial and temporal registration and avoids the added radiation exposure normally required to carry out comparative studies. (orig.)

  11. Visual perception and radiographic interpretation

    International Nuclear Information System (INIS)

    Papageorges, M.

    1998-01-01

    Although interpretation errors are common in radiology, their causes are still debated. Perceptual mechanisms appear to be responsible for a large proportion of mistakes made by both neophytes and trained radiologists. Erroneous perception of familiar contours can be triggered by unrelated opacities. Conversely, visual information cannot induce a specific perception if the observer is not familiar with the concept represented or its radiographicappearance. Additionally, the area of acute vision is smaller than is commonly recognized. Other factors, such as the attitude, beliefs,.: preconceptions, and expectations of the viewer, can affect what he or she ''sees'' whenviewing any object, including a radiograph. Familiarity with perceptual mechanisms and the limitations of the visual system as well as multiple readings may be necessary to reduce interpretation errors

  12. Picture chamber for radiographic system

    International Nuclear Information System (INIS)

    1977-01-01

    The picture chamber for a radiographic system is characterised by a base, a first electrode carried in the base, an X-ray irradiation window provided with an outer plate and an inner plate and a conducting surface which serves as a second electrode, which has a plate gripping it at each adjacent edge and which has at the sides a space which is occupied by a filling material, maintained at a steady pressure, by means of the mounting against the base and wherein the inner plate lies against the first electrode and which is provided with a split, and with means for the separation of the split in the area of the inner plate so that a fluid may be retained in the split. (G.C.)

  13. Radiographic techniques for digital mammography

    International Nuclear Information System (INIS)

    Horita, Katsuhei

    2007-01-01

    Since the differences in X-ray absorption between various breast tissues are small, a dedicated X-ray system for examination of the breast and a high-contrast, high-resolution screen/film system (SFM) (light-receiving system) are employed for X-ray diagnosis. Currently, however, there is a strong trend toward digital imaging in the field of general radiography, and this trend is also reflected in the field of mammographic examination. In fact, approximately 70% of facilities purchasing new mammography systems are now selecting a digital mammography system (DRM). Given this situation, this report reviews the differences between SFM and DRM and discusses the radiographic techniques and quality assurance procedures for digital mammography. (author)

  14. Gout: radiographic findings mimicking infection

    International Nuclear Information System (INIS)

    Rousseau, I.; Raymond-Tremblay, D.; Cardinal, E.; Beauregard, C.G.; Braunstein, E.M.; Saint-Pierre, A.

    2001-01-01

    Objective: To describe radiographic features of gout that may mimic infection. Design and patients: We report five patients with acute bacterial gout who presented with clinical as well as radiological findings mimicking acute bacterial septic arthritis or osteomyelitis. Three patients had delay in the appropriate treatment with the final diagnosis being established after needle aspiration and identification of urate crystals under polarized light microscopy. Two patients underwent digit amputation for not responding to antibiotic treatment and had histological findings confirming the diagnosis of gout. Conclusion: It is important for the radiologist to be aware of the radiological manifestations of acute gout that can resemble infection in order to avoid inappropriate diagnosis and delay in adequate treatment. The definitive diagnosis should rely on needle aspiration and a specific search for urate crystals. (orig.)

  15. Radiographic study of the odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Hyung Kyu [Department of Oral Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1983-11-15

    The author studied clinically and radiologically 55 cases which had been diagnosed as odontoma in SNUDH. The obtained results were as follows: 1. In sex distribution, there was no prevalence in both sexes. And the incidence was the highest in the 2nd decade (16 patient, 29%). 2. There were 42 cases of compound odontoma (76%) and 13 cases of complex odontoma (24%). In most cases, compound odontoma was located at the anterior portion (34 cases, 81%) and complex odontoma at the posterior portions (9 cases, 69%). 3. There was no apparent clinical symptom in compound odontoma (83%), but in complex odontoma, 80% of cases show swelling. 4. The adjacent root resorption was not observed in any case. 5. Five cases radiographically diagnosed as cystic odontoma were not confirmed histopathologically.

  16. Radiographic inspection on offshore platforms

    International Nuclear Information System (INIS)

    Soares, Sergio Damasceno; Sperandio, Augusto Gasparoni

    1994-01-01

    One of the great challenges for non-destructive inspection is on offshore platforms, where safety is a critical issue. Inspection by gammagraphy is practically forbidden on the platform deck due to problems to personnel safety and radiological protection. Ir-192 sources are used and the risk of an accident with loss of radioisotope must be considered. It is unfeasible to use gammagraphy, because in case of an accident the rapid evacuation from the platform would be impossible. This problem does not occur when X-ray equipment is used as the radiation source. The limited practicality and portability of the X-ray equipment have prevented its use as a replacement for the gammagraphy. This paper presents the preliminary tests to see the viable use of radiographic tests with constant potential on offshore platforms. (author). 2 refs., 1 fig., 2 tabs, 3 photos

  17. Radiographic evaluation of hallux valgus

    International Nuclear Information System (INIS)

    Richardson, M.L.; Hansen, S.T.; Kilcoyne, R.F.

    1987-01-01

    This paper presents the common preoperative and postoperative findings in hallux valgus, a common foot disorder of multiple etiologies, which can lead to significant foot pain and deformity. Little has been published in radiologic literature about the proper initial radiographic workup and the postoperative follow-up of this very common and very treatable cause of foot pain. Besides the primary findings of varus angulation of the first metatarsal and valgus angulation of the great toe, one may also see dorsal slaying of the first metatarsal head. As increased weight is borne by the central metatarsals, they may develop hyperostosis and stress fractures. Angular deformities of the hallux sesamoid joint and lesser toes may also be seen

  18. Glass Foreign Body Hand Radiograph

    Directory of Open Access Journals (Sweden)

    Hamid Ehsani-Nia, DO

    2018-04-01

    Full Text Available History of present illness: A 27-year-old female sustained an injury to her left hand after she tripped and fell on a vase. She presented to the emergency department (ED complaining of pain over the laceration. Upon examination, patient presented with multiple small abrasions of the medial aspect of the left 5thdigit that are minimally tender. Additionally, she has one 0.5cm linear laceration of the medial aspect of the 5thmetacarpal with severe tenderness in the area and palpable underlying foreign body. Significant findings: Left hand plain radiography demonstrated a subcutaneous foreign body medial to the 5thmetacarpal that is radiopaque, trapezoidal in shape, and measures approximately 11mm x 3mm. Discussion: Laceration repairs are amongst the most common procedures in the emergency department; however, consideration for foreign body is often underdiagnosed. Imaging is performed in only about 11% of all traumatic wounds in the ED.1 Of those injuries relating to the hand that are subsequently imaged, about 15% are found to have a foreign body.2,3 Additionally, it is estimated that foreign bodies are present in 7% to 8.7% of all wounds caused by glass objects.4,5 Glass is among the most common foreign bodies in lacerations, and fortunately they are radiopaque and relatively well visualized radiographically. It has been demonstrated that 2mm glass foreign bodies have a 99% detection rate with radiography, and 1mm glass foreign bodies an 83% detection rate.6 Patient perception of foreign body has a positive predictive value of 31%, making it a poor source in influencing clinical decision-making to obtain wound radiographs.3 Clinicians should have a high suspicion for foreign body in lacerations, particularly those caused by glass, and utilize close physical examination and imaging for evaluation. Topics: Radiography, glass, foreign body, trauma

  19. Conversion into numerical form of radiographic images

    International Nuclear Information System (INIS)

    Cappabianca, C.; Della Rocca, A.B.; Ferriani, S.

    1986-01-01

    Radiographic means are widely used for non destructive testing. However, human and technological factors strongly influence reliability of the results and further use of these technique. Image Processing can help to overtake those difficulties if radiographic films are previously digitized. This paper shows methods and equipments used in this field. The system EDI (Enea Digital. Imagery) operating in Casaccia Energy Research Centre is described

  20. Dental Radiographs Ordered by Dental Professionals: an ...

    African Journals Online (AJOL)

    Conclusions: Even in resource limited settings dental caries is still the regular indication for taking dental radiographs, and periapical views are the most frequent type of radiograph ordered. Maxillary central incisors and mandibular molars were types of teeth commonly x-rayed mainly due to the aesthetic importance of the ...

  1. Digital interactive learning of oral radiographic anatomy.

    Science.gov (United States)

    Vuchkova, J; Maybury, T; Farah, C S

    2012-02-01

    Studies reporting high number of diagnostic errors made from radiographs suggest the need to improve the learning of radiographic interpretation in the dental curriculum. Given studies that show student preference for computer-assisted or digital technologies, the purpose of this study was to develop an interactive digital tool and to determine whether it was more successful than a conventional radiology textbook in assisting dental students with the learning of radiographic anatomy. Eighty-eight dental students underwent a learning phase of radiographic anatomy using an interactive digital tool alongside a conventional radiology textbook. The success of the digital tool, when compared to the textbook, was assessed by quantitative means using a radiographic interpretation test and by qualitative means using a structured Likert scale survey, asking students to evaluate their own learning outcomes from the digital tool. Student evaluations of the digital tool showed that almost all participants (95%) indicated that the tool positively enhanced their learning of radiographic anatomy and interpretation. The success of the digital tool in assisting the learning of radiographic interpretation is discussed in the broader context of learning and teaching curricula, and preference (by students) for the use of this digital form when compared to the conventional literate form of the textbook. Whilst traditional textbooks are still valued in the dental curriculum, it is evident that the preference for computer-assisted learning of oral radiographic anatomy enhances the learning experience by enabling students to interact and better engage with the course material. © 2011 John Wiley & Sons A/S.

  2. Consultant breast radiographers: Where are we now?

    International Nuclear Information System (INIS)

    Rees, Zebby

    2014-01-01

    Introduction: The aim of this study is to: • Evaluate the current role of the consultant breast radiographer. • Compare current practice with the four key components for consultant practice. • Gauge the support of radiologist colleagues. • Determine the other professional commitments involved with the role. This study could be the precursor for a macro study of all consultant radiographer practice in other specialities. Methodology: Methodology used was a comparative ethnographic study. Questionnaires to the 24 consultant breast radiographers currently in post, and consultant breast radiologists, who work with them, were conducted. Data collection was a qualitative thematic approach. Conclusion: Consultant breast radiographers provide high quality care to patients through excellent clinical practice, leadership and good communication. However, this study shows hospital Trusts emphasis for non medical consultants is for clinical practice first. Some radiologists are still a barrier to progression for consultant breast radiographers, and radiologists have a big influence in recruitment decisions. Consultant breast radiographer posts are well established, their numbers are increasing through recognition of the role and of their abilities and performance. Consultant breast radiographers state that becoming a consultant is the major achievement of their career, proving the Society of Radiographers' vision of the four-tier career structure has been well received by the radiography profession

  3. Equipment for fully automatic radiographic pipe inspection

    International Nuclear Information System (INIS)

    Basler, G.; Sperl, H.; Weinschenk, K.

    1977-01-01

    The patent describes a device for fully automatic radiographic testing of large pipes with longitudinal welds. Furthermore the invention enables automatic marking of films in radiographic inspection with regard to a ticketing of the test piece and of that part of it where testing took place. (RW) [de

  4. Automatic Cobb Angle Determination From Radiographic Images

    NARCIS (Netherlands)

    Sardjono, Tri Arief; Wilkinson, Michael H. F.; Veldhuizen, Albert G.; van Ooijen, Peter M. A.; Purnama, Ketut E.; Verkerke, Gijsbertus J.

    2013-01-01

    Study Design. Automatic measurement of Cobb angle in patients with scoliosis. Objective. To test the accuracy of an automatic Cobb angle determination method from frontal radiographical images. Summary of Background Data. Thirty-six frontal radiographical images of patients with scoliosis. Methods.

  5. Influence of radiographic contrast media on phagocytosis

    International Nuclear Information System (INIS)

    Rasmussen, F.; Georgsen, J.; Grunnet, N.; Aalborg Sygehus

    1988-01-01

    To evaluate the influence of radiographic contrast media (CM) on human polymorphonuclear leucocytes (PML), the ability of these cells to ingest latex particles after in vitro exposure to five different radiographic contrast media was investigated. All CM inhibited the phagocytic properties of PML. The inhibition was dose dependent. The inhibitory effect was partly due to hyperosmolality but CM specific inhibition was also evident. (orig.)

  6. Chest Radiographic Findings in Newly Diagnosed Pulmonary ...

    African Journals Online (AJOL)

    Five hundred newly diagnosed cases of Pulmonary Tuberculosis were treated with directly observed short-course treatment and 100 of them had chest radiographic examination done. The various chest radiographic patterns in the 100 subjects were studied and included: Fluffy exudative changes 80(80%), fibrosis 70(70%) ...

  7. Digital image processing of periapical radiographs with low dose of radiation

    International Nuclear Information System (INIS)

    Kerbauy, Warley David; Moraes, Luiz Cesar de

    1996-01-01

    The aim of the study was to evaluate whether digitized images obtained from peri apical radiographs taken with low dose of radiation could be improved with the aid of a computer software (Photo Styler) for digital treatment. Serial and standardized radiographs of molar and pre molar areas were studied. A total of 57 images equivalent to the radiographs taken with reduced exposure time (60 and 80% of the time considered normal), digitized and treated, were submitted to the evaluation of seven examiners which compared them with those images without treatment. It was verified that about 80% of the images equivalent to the radiographs taken with 60% reduction of ordinary exposure time were considered to having quality for supporting diagnosis. As for the images taken with 80% reduction of ordinary exposure time, about 50% of them were considered suitable for the same purpose. (author)

  8. Fragile X syndrome: panoramic radiographic evaluation of dental anomalies, dental mineralization stage, and mandibular angle.

    Science.gov (United States)

    Sabbagh-Haddad, Aida; Haddad, Denise Sabbagh; Michel-Crosato, Edgard; Arita, Emiko Saito

    2016-01-01

    The purpose of this study was to evaluate the dental radiographic characteristics as described in 40 records of patients with panoramic radiography. The patients were in the range of 6-17 years old, and were divided into two groups (20 subjects who were compatible with the normality standard and 20 individuals diagnosed with the FXS), which were matched for gender and age. Analysis of the panoramic radiographic examination involved the evaluation of dental mineralization stage, mandibular angle size, and presence of dental anomalies in both deciduous and permanent dentitions. The results of radiographic evaluation demonstrated that the chronology of tooth eruption of all third and second lower molars is anticipated in individuals with FXS (pdental anomalies. In addition, an increase was observed in the mandibular angle size in the FXS group (pdental radiographic changes is of great importance for dental surgeons to plan the treatment of these individuals.

  9. Can Australian radiographers assess screening mammograms accurately? Biennial follow-up from a four year prospective study and lesion analysis

    International Nuclear Information System (INIS)

    Moran, S.; Warren-Forward, H.

    2016-01-01

    Introduction: Globally, the role of the radiographer is changing; some countries have developed advanced roles with specific scopes of practice. Other countries, like Australia, are in the process of this change. This paper demonstrates the abilities of Australian radiographers in mammogram screen reading, highlighting some of their specific difficulties with different lesion types. Method: Six experienced radiographers participated in a prospective study, screen reading 2000 mammograms each between 2010 and 2011. This paper looks at the results of those same women at biennial re-screen. Analysis of the results included validation of normal results by negative follow-up screens and new cancers at biennial review; there is also analysis on the types of lesions detected and missed. Results: After biennial review, three cancers in 2013/2014 had been marked as abnormal by one radiographer two years prior, which increased her sensitivity from 64% to 85%. Sensitivity for the radiologists decreased from the assumed 100% to 95%. Radiographers appeared to be skilled in detection of calcifications and architectural distortions but had difficulty with non-specific densities. Conclusion: This study demonstrates the potential for Australian radiographers to enhance the accuracy of screen reading programs. - Highlights: • Radiographers have the potential to increase breast cancer detection rates. • Radiographers appear to be skilled at detecting calcifications. • Lesions commonly overlooked by radiographers could be targeted for training.

  10. Non-radiographic methods for IGRT

    International Nuclear Information System (INIS)

    Semwal, Manoj K.

    2016-01-01

    The primary goal of radiation therapy is to deliver a tumouricidal dose within a defined target volume while minimizing dose to surrounding normal tissues. In recent years, advanced technologies such as intensity modulated radiotherapy (IMRT), stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT) have been used to meet the goal. High dose conformity and steep dose gradients beyond the target volume achieved with these technologies warrant high level of accuracy in the dose delivery. Therefore, accurate patient localization, target segmentation and motion compensation have become mandatory requirements. Several technologies have been developed over the years to image the patient for treatment planning and for subsequent daily imaging/tracking while the patient is on the treatment table. For image guided radiotherapy (IGRT) some of the technologies are kilovoltage (kV) x-rays imaging, in-room computed tomography (CT), kV and MV cone-beam CT(CBCT). One of the chief drawbacks of these technologies is addition of radiation dose to the patients. There are other technologies that do not use ionizing radiation such as USG, MRI, patient surface monitoring using infrared and optical radiation, and radiofrequency (RF)-based localization/tracking systems that are also being developed for the purpose. These technologies may be collectively called as non-radiographic (NR) technologies for IGRT

  11. Clarifying Normalization

    Science.gov (United States)

    Carpenter, Donald A.

    2008-01-01

    Confusion exists among database textbooks as to the goal of normalization as well as to which normal form a designer should aspire. This article discusses such discrepancies with the intention of simplifying normalization for both teacher and student. This author's industry and classroom experiences indicate such simplification yields quicker…

  12. Validity of radiographic assessment of ankylosis

    International Nuclear Information System (INIS)

    Stenvik, A.; Beyer-Olsen, E.; Aabyholm, F.; Haanaes, H.R.; Gerner, N.W.

    1990-01-01

    The accuracy and sensitivity of radiographic assessments of reactive processes in dental tissues were evaluated by comparison of radiographs and histologic sections. Experimental lesions inflicted on the roots of 10 monkey incisors had been observed by means of serially obtained radiographs over a period of 315 to 370 days. The material was used for evaluation of radiographic assessment of ankylosis. For comparative purposes, assessment of the experimental lesion penetrating to the pulp and periapical radiolucency was added. True and falsely positive or negative recordings formed the basis for calculation of the accuracy and sensitivity of the radiographic assessment. The sensitivity, or the obsevers ability to detect the actual changes, was high for pulp penetration, intermediate for inflammation, and low for ankylosis. 6 refs., 3 figs., 2 tabs

  13. Consultant radiographers: Profile of the first generation

    International Nuclear Information System (INIS)

    Forsyth, Lesley J.; Maehle, Valerie

    2010-01-01

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  14. Consultant radiographers: Profile of the first generation

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, Lesley J., E-mail: l.forsyth@rgu.ac.u [School of Health Sciences, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom); Maehle, Valerie [Faculty of Health and Social Care, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom)

    2010-11-15

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  15. iPhone 4s photoplethysmography: which light color yields the most accurate heart rate and normalized pulse volume using the iPhysioMeter Application in the presence of motion artifact?

    Directory of Open Access Journals (Sweden)

    Kenta Matsumura

    Full Text Available Recent progress in information and communication technologies has made it possible to measure heart rate (HR and normalized pulse volume (NPV, which are important physiological indices, using only a smartphone. This has been achieved with reflection mode photoplethysmography (PPG, by using a smartphone's embedded flash as a light source and the camera as a light sensor. Despite its widespread use, the method of PPG is susceptible to motion artifacts as physical displacements influence photon propagation phenomena and, thereby, the effective optical path length. Further, it is known that the wavelength of light used for PPG influences the photon penetration depth and we therefore hypothesized that influences of motion artifact could be wavelength-dependant. To test this hypothesis, we made measurements in 12 healthy volunteers of HR and NPV derived from reflection mode plethysmograms recorded simultaneously at three different spectral regions (red, green and blue at the same physical location with a smartphone. We then assessed the accuracy of the HR and NPV measurements under the influence of motion artifacts. The analyses revealed that the accuracy of HR was acceptably high with all three wavelengths (all rs > 0.996, fixed biases: -0.12 to 0.10 beats per minute, proportional biases: r =  -0.29 to 0.03, but that of NPV was the best with green light (r = 0.791, fixed biases: -0.01 arbitrary units, proportional bias: r = 0.11. Moreover, the signal-to-noise ratio obtained with green and blue light PPG was higher than that of red light PPG. These findings suggest that green is the most suitable color for measuring HR and NPV from the reflection mode photoplethysmogram under motion artifact conditions. We conclude that the use of green light PPG could be of particular benefit in ambulatory monitoring where motion artifacts are a significant issue.

  16. Cash's textbook of chest, heart and vascular disorders for physiotherapists

    Energy Technology Data Exchange (ETDEWEB)

    Downie, P.A.; Innocenti, D.M.; Jackson, S.E.

    1987-01-01

    This book includes a chapter on chest radiographs. A very high proportion of the patients treated by physiotherapy will have had a chest radiograph (x-ray) either because their primary disease is pulmonary or there is some long standing heart or lung illness which should be taken into account during the management of an acute problem. The chapter outlines the principles involved in reading the radiograph.

  17. The radiographic acromiohumeral interval is affected by arm and radiographic beam position

    Energy Technology Data Exchange (ETDEWEB)

    Fehringer, Edward V.; Rosipal, Charles E.; Rhodes, David A.; Lauder, Anthony J.; Feschuk, Connie A.; Mormino, Matthew A.; Hartigan, David E. [University of Nebraska Medical Center, Department of Orthopaedic Surgery and Rehabilitation, Omaha, NE (United States); Puumala, Susan E. [Nebraska Medical Center, Department of Preventive and Societal Medicine, Omaha, NE (United States)

    2008-06-15

    The objective was to determine whether arm and radiographic beam positional changes affect the acromiohumeral interval (AHI) in radiographs of healthy shoulders. Controlling for participant's height and position as well as radiographic beam height and angle, from 30 right shoulders of right-handed males without shoulder problems four antero-posterior (AP) radiographic views each were obtained in defined positions. Three independent, blinded physicians measured the AHI to the nearest millimeter in 120 randomized radiographs. Mean differences between measurements were calculated, along with a 95% confidence interval. Controlling for observer effect, there was a significant difference between AHI measurements on different views (p<0.01). All pair-wise differences were statistically significant after adjusting for multiple comparisons (all p values <0.01). Even in healthy shoulders, small changes in arm position and radiographic beam orientation affect the AHI in radiographs. (orig.)

  18. suPAR level is associated with myocardial impairment assessed with advanced echocardiography in patients with type 1 diabetes with normal ejection fraction and without known heart disease or end-stage renal disease

    DEFF Research Database (Denmark)

    Theilade, Simone; Rossing, Peter; Eugen-Olsen, Jesper

    2016-01-01

    AIM: Heart disease is a common fatal diabetes-related complication. Early detection of patients at particular risk of heart disease is of prime importance. Soluble urokinase plasminogen activator receptor (suPAR) is a novel biomarker for development of cardiovascular disease. We investigate if su...

  19. Heart Truth

    Science.gov (United States)

    ... health! Get a free badge or banner to post to your website or blog. Are you at risk for heart disease? Here's how to find out . Planning to use The Heart Truth logo? Check out our logo guidelines and downloads. ...

  20. Heart Disease

    Science.gov (United States)

    ... it may be caused by diseases, such as connective tissue disorders, excessive iron buildup in your body (hemochromatosis), the buildup of abnormal proteins (amyloidosis) or by some cancer treatments. Causes of heart infection A heart infection, ...

  1. Heart Attack

    Science.gov (United States)

    ... family history of heart attack race – African Americans, Mexican Americans, Native Americans, and native Hawaiians are at ... Your doctor will prescribe the medicines that are right for you. If you have had a heart ...

  2. Determining symptoms for chest radiographs in patients with swine flu (H1N1)

    International Nuclear Information System (INIS)

    Al-Nakshabandi, Nizar A.

    2011-01-01

    The question arises about the chest X-ray findings and clinical symptoms in swine flu and about the most important clinical finding when correlated with the chest radiograph. Should physicians order a chest X-ray in each patient suspected of having swine flu? There were 179 patients with a high suspicion of swine flu. All 179 patients had an initial chest radiograph. As many as 65 males (representing 56% of the projected study population) had a normal chest radiograph, while 35 males (representing 55.6% of the study population) had an abnormal chest X-ray. As many as 51 females (representing 44% of the population) had a normal chest X-ray, while 20 females (representing 44% of the study population) had abnormal chest X-rays. Polymerase chain reaction (PCR) was not a determining factor for normal vs. abnormal chest X-ray (CXR). Rapid antigen test was not a determining factor for normal vs. abnormal CXR. Fever was not a determining factor for normal vs. abnormal CXR. Cough appears to be a determining factor for normal vs. abnormal CXR. Sore throat appears to be a determining factor for normal vs. abnormal CXR. Chest pain was not a determining factor for normal vs. abnormal CXR. Presence of cough with PCR was statistically significant. In my opinion, chest radiographs in patients with suspected H1N1 should only be obtained if there is a cough or sore throat. Other symptoms associated with H1N1 do not warrant a chest radiograph unless absolutely necessary

  3. Radiological visualization of prosthetic heart valves in situ

    International Nuclear Information System (INIS)

    Hoffmeister, H.M.; Pirschel, J.

    1986-01-01

    To determine the radiographic appearance of prosthetic heart valves 15 different models were investigated in situ. Fluoroscopy with detail radiographs and standard chest-radiographs were used for identification of the specific type of the prosthesis, for determination of details of the valve apparatus and for evaluation of the motion of the valve disc/ball. - Fluoroscopy and routine radiographs provided sufficient information to identify all prosthetic heart valves with exception of the Xenomedica bioprosthesis. If radiopaque material was used for the valve disc/ball, fluoroscopic assessment of the function of the valve was possible. Thus, in most types of disc or ball valves the opening/closing of the valve can be visualized, whereas in bioprosthesis a radiological determination of the mechanical function is not possible. (orig.) [de

  4. Heart pacemaker

    Science.gov (United States)

    Cardiac pacemaker implantation; Artificial pacemaker; Permanent pacemaker; Internal pacemaker; Cardiac resynchronization therapy; CRT; Biventricular pacemaker; Arrhythmia - pacemaker; Abnormal heart ...

  5. Diabetes, Dyslipidemia, and Heart Protection

    Science.gov (United States)

    Fact Sheet Diabetes, Dyslipidemia, and Heart Protection What is dyslipidemia? Cholesterol and triglycerides, known as lipids, are fatty substances that the body normally produces. Dyslipidemia means that lipid levels ...

  6. Digital subtraction radiographic evaluation of the standardize periapical intraoral radiographs

    International Nuclear Information System (INIS)

    Cho, Bong Hae; Nah, Kyung Soo

    1993-01-01

    The geometrically standardized intraoral radiographs using 5 occlusal registration material were taken serially from immediate, 1 day, 2, 4, 8, 12 and 16 weeks after making the bite blocks. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exaflex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  7. MRI reporting by radiographers: Findings of an accredited postgraduate programme

    Energy Technology Data Exchange (ETDEWEB)

    Piper, Keith [Allied Heath Professions Department, Canterbury Christ Church University, North Holmes Road, Canterbury, Kent CT1 1QU (United Kingdom)], E-mail: keith.piper@canterbury.ac.uk; Buscall, Kaie [Allied Heath Professions Department, Canterbury Christ Church University, North Holmes Road, Canterbury, Kent CT1 1QU (United Kingdom); Thomas, Nigel [X-Ray Department, Trafford General Hospital, Manchester M41 5SL (United Kingdom)

    2010-05-15

    . These results suggest therefore that in an academic setting, these groups of radiographers have the ability to correctly identify normal investigations and are able to provide a report on the abnormal appearances to a high standard. Further work is required to confirm the clinical application of these findings.

  8. Computerized detection of lung nodules in digital chest radiographs

    International Nuclear Information System (INIS)

    Giger, M.L.; Doi, K.; MacMahon, H.

    1987-01-01

    Detection of cancerous lung nodules in chest radiographs is one of the more important tasks performed by a radiologist. In addition, the ''miss rate'' associated with the radiographic detection of lung nodules is approximately 30%. A computerized scheme that alerts the radiologist to possible locations of lung nodules should allow this number of false-negative diagnoses to be reduced. The authors are developing a computer-aided nodule detection scheme based on a difference image approach. They attempt to eliminate the camouflaging background structure of the normal lung anatomy by creating, from a single-projection chest image, two images: one in which the signal-to-noise ratio (SNR) of the nodule is maximized and another in which that SNR is suppressed while the processed background remains essentially the same. Thus, the difference between these two processed images should consist of the nodule superimposed on a relatively uniform background in which the detection task may be simplified. This difference image approach is fundamentally different from conventional subtraction techniques (e.g., temporal or dual-energy subtraction) in that the two images which are subtracted arise from the same single-projection chest radiograph. Once the difference image is obtained, thresholding is performed along with tests for circularity, size and growth in order to extract the nodules. It should be noted that once an original chest image is input to the computer the nodule detection process is totally automated

  9. Travel and Heart Disease

    Science.gov (United States)

    ... a game park for the day,” Gandy said. Plane Precautions Sitting immobile on long plane flights can slightly increase a normal person’s risk ... Disease (PAD) • Stroke • Vascular Health • Venous Thromboembolism (VTE) • Consumer Healthcare • Tools For Your Heart Health • Watch, Learn & ...

  10. Gamma radiographic exposure time indicator

    International Nuclear Information System (INIS)

    Risbud, V.H.; Thiagarajan, A.; Gangadharan, P.

    1979-01-01

    In industrial radiography, with the proper selection of source and film, the radiographic quality depends very much on the exposure time, which in turn depends upon the source strength and the source to film distance. Conventional methods to arrive at correct exposure time involve time consuming calculations and in these methods the knowledge of the above mentioned parameters is imperative. An instrument to determine the required exposure time has been developed which indicates exposure times in about 30 secs. This covers two commonly used gamma radiography sources, viz., 192 Ir and 60 Co and six commonly used radiography films of different speeds. Knowledge of source strength and source to film distance is not required with the use of this instrument. With a knowledge of the total exposure required by the film to give the required sensitivity and by the measurement of radiation level at the film location, the correct exposure time is determined. The radiation level is measured by placing a GM counter behind the radiographic specimen at the film location. To match the responses of the film and the GM counter, the counter is incorporated in a suitably designed probe. In this instruments, an integrator to integrate the GM-pulses and a constant current integrator (timer) are started simultaneously. The voltage at the GM-pulse integrator is compared with a preselected voltage, (selected on the basis of film type, source, source strength and order of object thickness) by a comparator. The comparator is so adjusted that when the GM-pulse integrator voltage exceeds the preselected voltage, it switches its state and stops the integration of constant current. The constant current integrator output which is proportional to the time taken for the GM-pulse integrator to reach the preselected voltage, is read on a meter graduated in terms of exposure time. The instrument can measure exposure times from 5 minutes to 10 hours read in two ranges, the range-changing being automatic

  11. Reporting by radiographers: a policy and practice guide

    International Nuclear Information System (INIS)

    Paterson, Audrey M.; Price, Richard C.; Thomas, Adrian; Nuttall, Lorraine

    2004-01-01

    Reporting by radiographers and other non-medical staff has developed considerably in the past decade, and especially so since the College of Radiographers published its vision paper on reporting by radiographers, in 1997. It was felt necessary, therefore, to develop guidance to assist radiographers and others undertaking radiographic reporting. The guidance provided includes guidance on planning and implementing a reporting service using reporting radiographers; the education, continuing education and support required by reporting radiographers; quality and standards related to reporting; and the nature of a report. Broader issues that will need to be addressed as reporting by radiographers becomes the norm are also raised

  12. Agreement between radiographic and photographic trabecular patterns

    International Nuclear Information System (INIS)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der; Spruijt, R.J.; Mosekilde, L.

    1998-01-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach's α>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  13. Agreement between radiographic and photographic trabecular patterns

    Energy Technology Data Exchange (ETDEWEB)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der [Dept. of Oral Radiology, Academic Centre for Dentistry, Amsterdam (Netherlands); Spruijt, R.J. [Div. of Psychosocial Research and Epidemiology, Netherlands Cancer Inst., Amsterdam (Netherlands); Mosekilde, L. [Dept. of Cell Biology, Univ. of Aarhus (Denmark)

    1998-11-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach`s {alpha}>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  14. Radiographic markers - A reservoir for bacteria?

    International Nuclear Information System (INIS)

    Tugwell, Jenna; Maddison, Adele

    2011-01-01

    Introduction: Amongst the most frequently handled objects in the radiology department are radiographic markers. They are personal accessories used with every patient, and are kept in the radiographers pockets when not utilised. Upon enquiry it was discovered that many radiographers disregarded the potential of these accessories to become a vector for cross-contamination thus never or rarely clean them. The aims of this study were therefore to identify if radiographic markers are a reservoir for bacteria and to establish an effective cleaning method for decontaminating them. Methodology: 25 radiographers/student radiographers were selected for this study. Swabbing of their markers prior and post cleaning took place. The microbiology laboratory subsequently analyzed the results by quantifying and identifying the bacteria present. The participants also completed a closed questionnaire regarding their markers (e.g. frequency of cleaning and type of marker) to help specify the results gained from the swabbing procedure. Results: From the sample swabbed, 92% were contaminated with various organisms including Staphylococcus and Bacillus species, the amount of bacteria present ranged from 0 to >50 CFU. There were no significant differences between disinfectant wipes and alcohol gel in decontaminating the markers. Both successfully reduced their bacterial load, with 80% of the markers post cleaning having 0 CFU. Conclusion: The results indicated that radiographic markers can become highly contaminated with various organisms thus serve as a reservoir for bacteria. In addition, the markers need to be cleaned on a regular basis, with either disinfectant wipes or alcohol gel to reduce their bacterial load.

  15. Radiographers and trainee radiologists reporting accident radiographs: A comparative plain film-reading performance study

    International Nuclear Information System (INIS)

    Buskov, L.; Abild, A.; Christensen, A.; Holm, O.; Hansen, C.; Christensen, H.

    2013-01-01

    Aim: To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital. Materials and methods: Plain radiographs of the appendicular skeleton from 1000 consecutive emergency room patients were included in the study: 500 primarily reported by radiographers and 500 by trainee radiologists. The final reporting was subsequently undertaken by a consultant radiologist in consensus with an orthopaedic surgeon. Two observers classified reports as either true positive/negative or false positive/negative based on the final report, which was considered the reference standard. To evaluate the severity of incorrect primary reports, errors were graded into three categories concerning clinical impact and erroneous reports graded as the most severe category were subsequently analysed. Mann–Whitney and Chi-squared tests were used to compare differences and associations between radiographers versus trainee radiologists regarding film reporting. Results: The sensitivity for correct diagnosis was 99% for reporting radiographers and 94% for trainee radiologists. The specificity was found to be 97% for reporting radiographers and 99% for trainee radiologists. Radiographers missed significantly fewer fractures (n = 2) than trainee radiologists (n = 14; p = 0.006) but had a higher, but not significant, degree of overcalling. No significant difference was found between groups regarding clinical impact of incorrect reporting. Conclusion: Trained radiographers report accident radiographs of the extremities with high accuracy and constitute a qualified resource to help meet increasing workload and demands in quality standards.

  16. Metaiodobenzylguanidine and heart rate variability in heart failure

    International Nuclear Information System (INIS)

    Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko

    1998-01-01

    It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac 123 I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)

  17. Metaiodobenzylguanidine and heart rate variability in heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko [Hamamatsu Univ., Shizuoka (Japan). School of Medicine; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko

    1998-10-01

    It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)

  18. Unicystic Jaw Lesions: A Radiographic Guideline

    Directory of Open Access Journals (Sweden)

    Giju George

    2010-01-01

    Full Text Available The unilocular radiolucencies remain the topic of much interest for the clinicians and histhopathologists for decades. Adequate use of diagnostic aids and careful observation will clinically help the dentist to arrive at a proper diagnosis and renders quality treatment to patients. Despite of the development of various cross-sectional imaging modalities, the radiograph still remains as the first and most important investigation. Jaw bone lesions, especially unilocular ones, are difficult to diagnose radiologically because of their similar radiographic appearance. It is, thus, very important for the clinician to have a sound knowledge of various radiographic features of the tooth and its supporting structures.

  19. A case of a found radiographic source

    International Nuclear Information System (INIS)

    Pucelj, B.; Korun, M.; Kavsek, D.; Kreft, Z.; Krizman, M.; Martincic, R.; Rosman, M.; Sutej, T.

    1996-01-01

    High dose-rate levels were detected outdoors in the vicinity of a bunker used for storage of radiographic sources in a plant which manufactures metallic products. The investigation revealed that radiation was due to a buried sealed radiographic source, containing 28 GBq of 137 Cs. A special republic radiological emergency team removed the source in a carefully planned operation. There was no evidence for overexposure of the population or of radiographic and other workers of the plant. The highest dose to the recovery team was 50 μSv

  20. Consultant radiographer leadership - A discussion

    International Nuclear Information System (INIS)

    Hogg, Peter; Hogg, Dianne; Henwood, Suzanne

    2008-01-01

    Effective leadership can be defined in many ways and is an essential element of successful organisations; poor leadership can result in problems such as low staff morale, high staff turnover and reduced productivity. Effective leadership behaviours are well documented in the literature and various leadership models have been proposed that illustrate these behaviours. This discussion paper does not focus on any particular model. Instead it considers the 'Leadership Qualities Framework' which was developed specifically for use within the UK National Health Service. This framework draws upon a range of leadership models and as such it gives a broad indication of leadership behaviours. The framework comprises three components - 'personal qualities', 'setting direction' and 'delivering the service'. This paper commences with an argument as to why effective leadership is important in organisations generally, and specifically within healthcare organisations. Various examples of leadership are illustrated from within and outside the NHS in order to demonstrate effective leadership behaviours. The Leadership Qualities Framework is then examined, along with scenarios to illustrate effective leadership behaviours in context (i.e. within a healthcare organisation). Subsequent reflections on the scenarios aim to identify leadership behaviours that are explained within the framework. The final element of this paper draws on [limited] published evidence of where consultant radiographers have demonstrated effective leadership behaviours. In this section the published evidence is examined and reflected upon. At the end of the article we indicate additional reading for those who wish to further develop their theoretical and practical leadership skills

  1. Radiographic observation for tuberculous spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chul Se; Jung, Marn Kyoon; Kim, Byung Soo [College of Medicine, Busan National University, Busan (Korea, Republic of)

    1974-04-15

    Radiographic observation of 152 cases of tuberculous spondylitis selected from total 194 cases of tuberculous arthritis during the past 6 years and 8 months, was carried out to study. 1. The youngest one was 15 months old male infant of active tuberculous spondylitis. The active tuberculous spondylitis under 10 years of age were 50 percent (28 cases). 2. The ratio of male to female was 1.5:1 3. The most common site of involvement was the lumbar spine which was 44.1 percent of the total tuberculous spondylitis. The next were thoracic spine (33.6%), and thoraco-lumber spine (13.1%). 4. The most common roentgenographic findings are bony destructions of the vertebral bodies which were 97.4 percent. The next were joint space narrowing (93.4%), osteoporosis (79.6%), kyphosis (34.2%), fusion deformity of the vertebral body (25.7%), and cold abscess shadow (16.4%). 5. The most of patients (88.8%) had or have been pulmonary tuberculous lesions. 6. In annual incidence, the number of patients were not changed greatly.

  2. Radiographic evaluation of AIDS patients

    International Nuclear Information System (INIS)

    Le Blang, S.D.; Witheman, M.L.; Donovan Post, M.J.; Casillas, J.V.

    1995-01-01

    Morphological imaging, based on the use of various techniques including ultrasound, X-ray computed tomography (CT), and magnetic resonance imaging (MRI), plays an important role in the characterization, diagnosis and follow-up of patients with Human Immunodeficiency Virus (HIV) infection and Acquired Immunodeficiency Syndrome (AIDS). While the presence of thoracic infections, the most frequently observed illnesses in AIDS patients, can best be performed by using conventional chest films and CT, the assessment of cerebral involvement in AIDS patients - characterized by the presence of focal masses, demyelination, meningitis, and infarction - is best achieved using MRI. The work-up of patients with gastrointestinal symptoms should include the use of ultrasound for the evaluation of visceral involvement and lymphadenopathy, completed by CT to further characterize pathologic conditions in either the bowel or visceral organs. Ultrasound is the screening exam of choice in AIDS patients with suspected renal disease, but other methods may be necessary for the assessment of the complications due to pharmacological treatment. Musculoskeletal complications may require the combined use of all the above methods, since they may be caused by infections, tumors and rheumatologic illness. The use of the radiographic methods for the detection of the numerous forms of infections and malignancies in AIDS patients is described in detail for the various body districts

  3. Birkhoff normalization

    NARCIS (Netherlands)

    Broer, H.; Hoveijn, I.; Lunter, G.; Vegter, G.

    2003-01-01

    The Birkhoff normal form procedure is a widely used tool for approximating a Hamiltonian systems by a simpler one. This chapter starts out with an introduction to Hamiltonian mechanics, followed by an explanation of the Birkhoff normal form procedure. Finally we discuss several algorithms for

  4. Long-term statin therapy in patients with systolic heart failure and normal cholesterol: effects on elevated serum markers of collagen turnover, inflammation, and B-type natriuretic peptide.

    LENUS (Irish Health Repository)

    Abulhul, Esam

    2012-01-01

    The role of statin therapy in heart failure (HF) is unclear. The amino-terminal propeptide of procollagen type III (PIIINP) predicts outcome in HF, and yet there are conflicting reports of statin therapy effects on PIIINP.

  5. Inadequate pelvic radiographs: implications of not getting it right the first time.

    Science.gov (United States)

    Parker, S; Nagra, N S; Kulkarni, K; Pegrum, J; Barry, S; Hughes, R; Ghani, Y

    2017-09-01

    Introduction Pelvic radiography is a frequent investigation. European guidelines aim to ensure appropriate use and adequate quality. When initial images are inadequate, repeat radiographs are often required, which may have significant patient safety and economic implications. Objectives The study aimed to assess the adequacy of pelvic imaging across three orthopaedic centres, to identify causes for inadequate imaging and to establish the cost of inadequate imaging from financial and patient safety perspectives. Methods Pelvic radiographs were identified on Picture Archiving and Communication System software at three UK hospitals. Radiographs were assessed against European guidelines and indications for repeat imaging were analysed. Results A total of 1,531 sequential pelvic radiographs were reviewed. The mean age of patients was 60 years (range 5 months to 101 years). Of this total, 51.9% of images were suboptimal, with no significant difference across the three hospitals (P > 0.05). Hospital 3 repeated radiographs in 6.3% of cases, compare with 18.1% and 19.7% at hospitals 1 and 2, respectively (P > 0.05). Hospital 3 identified pathology missed on the initial radiograph in 1% of cases, compared with 5.4% and 5.5% at hospitals 1 and 2, respectively (P > 0.05). Out-of-hours imaging is associated with a higher rate of suboptimal quality (69.1%) compared with normal working hours (51.3%; P = 0.006). Adequacy rates vary with age (χ 2 = 43.62, P hours imaging.

  6. Evaluation of underexposed conventional radiographs after digitization

    International Nuclear Information System (INIS)

    Wenz, W.

    1993-01-01

    Inadequate exposure of analogue radiographs is reported in the literature to occur in 5-25% of cases. Therefore, the present study was performed to test whether selective image processing after digitization could reveal diagnostic details on underexposed radiographs. In addition, the minimal exposure values required for diagnostic purposes after adequate image processing were studied. Phantom studies, organ preparations and measurements of physical parameters with decreasing exposure values were performed. The detection of anatomic and pathologic (nondisplaced fracture lines, microcalcification and renal stones) structures were evaluated by 12 readers. Radiographs with exposure values 20-40% lower than 'ideal' values can provide adequate diagnostic images after digital processing. The diagnostic information is significantly impaired with values under 50% of the correct exposure values. In conclusion, this method is adequate to save underexposed radiographs for diagnostic purposes and to avoid repeated examinations. (orig.) [de

  7. Radiographic features of appendiceal colic in children

    International Nuclear Information System (INIS)

    Schisgall, R.M.

    1986-01-01

    The concept of appendiceal colic was introduced in 1980 to explain the common problem of recurrent crampy abdominal pain (RAP) in children. Children with appendiceal colic often have inspissated casts of stool as foreign bodies of the appendix. The radiographic findings of 115 children operated upon for appendiceal colic have been reviewed. The radiographic features of this syndrom have included: filling defects of the appendix (83% incidence of inspissated casts of stool within the appendix); partial filling of the appendix (44% incidence of fecal casts); retained barium behind 72 h (92% incidence of fecal casts blocking egress of barium); non-visualization of the appendix (42% incidence of fecal casts); and distention of the appendix (100% incidence of fecal casts). The correlation of radiographic and operative findings will be presented. A rational approach to the radiographic workup of a child with RAP will be presented. (orig.)

  8. Radiographic evaluation of coxofemoral joint laxity in dogs part II: Comparison of stress-radiographic positioning techniques in dogs with hip dysplasia

    International Nuclear Information System (INIS)

    Duangdaun Kaenkangploo; Phiwipha Kamonrat; Marissak Kalpravidh

    2002-01-01

    Two stress-radiographic positioning techniques for evaluation of coxofemoral joint laxity in dogs with hip dysplasia were compared with the standard technique. Forty, healthy, large breed dogs were divided into two groups of 20 dogs. Group 1 had normal hips. Group 2 were dogs with mild to moderated grade of hip dysplasia according to the Orthopedic Foundation for Animals (OFA) standard. Dogs were anesthetized and placed in dorsal recumbency before 3 radiographic techniques, standard hip-extended, 60 deg and 90 deg stress techniques, were taken. For the 60 deg stress technique, hind legs were extended in parallel to each other at 60 deg to the table top and femoral heads were manually pushed craniodorsally during exposure. For the 90 deg stress technique, femurs were positioned perpendicular to the table top, stifles were 90 deg flexed and adducted and femoral heads were manually pushed in a craniodorsal direction during exposure. Subluxation index (SI) and dorsolateral subluxation score (DLS score) of coxofemoral joints were assessed from radiographs. The SI of normal dogs from standard, 60 deg and 90 deg stress techniques were 0.15, 0.20 and 0.23 and of dysplastic dogs were 0.34, 0.40 and 0.41 respectively. The degress of subluxation assessed from the two stress technique radiographs were significantly greater (p0.05) than those shown on the standard technique radiographs in both groups of dogs. DLS scores of normal dogs from standard, 60 deg and 90 deg stress techniques were 65.1, 64.3 and 61.0 percent and of dysplastic dogs were 55.4, 53.6 and 47.6 percent respectively. Mean of DLS scores assessed from the 90 deg radiographs was significantly lower (p0.05) than those assessed from radiographs of other two teachniques in both groups of dogs. The findings suggested that the 90 deg stress technique is more efficient than the standard and 60 deg stress techniques for radiographic evaluation of coxofemoral joint laxity in dogs with mild hip dysplasia and early

  9. Radiographers and radiologists reporting plain radiograph requests from accident and emergency and general practice

    International Nuclear Information System (INIS)

    Brealey, S.D.; King, D.G.; Hahn, S.; Crowe, M.; Williams, P.; Rutter, P.; Crane, S.

    2005-01-01

    AIM: To assess selectively trained radiographers and consultant radiologists reporting plain radiographs for the Accident and Emergency Department (A and E) and general practitioners (GPs) within a typical hospital setting. METHODS: Two radiographers, a group of eight consultant radiologists, and a reference standard radiologist independently reported under controlled conditions a retrospectively selected, random, stratified sample of 400 A and E and 400 GP plain radiographs. An independent consultant radiologist judged whether the radiographer and radiologist reports agreed with the reference standard report. Clinicians then assessed whether radiographer and radiologist incorrect reports affected confidence in their diagnosis and treatment plans, and patient outcome. RESULTS: For A and E and GP plain radiographs, respectively, there was a 1% (95% confidence interval (CI) -2 to 5) and 4% (95% CI -1 to 8) difference in reporting accuracy between the two professional groups. For both A and E and GP cases there was an 8% difference in the clinicians' confidence in their diagnosis based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 2% and 8% difference in the clinicians' confidence in their management plans based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 1% and 11% difference in effect on patient outcome of radiographer or radiologist incorrect reports. CONCLUSION: There is the potential to extend the reporting role of selectively trained radiographers to include plain radiographs for all A and E and GP patients. Further research conducted during clinical practice at a number of sites is recommended

  10. Radiographer led supplementary anterior cruciate ligament MRI sequences: Technical report

    International Nuclear Information System (INIS)

    Richards, Paula J.; McCall, Iain; Kraus, Alexandra; Jones, Mary; Walley, Gayle; Gibson, Kathryn; Maffulli, Nicola

    2012-01-01

    Aims: To compare different supplementary MRI sequences of the ACL to arthroscopy and determine the diagnostic performance of each sequence. To ascertain whether radiographers could identify patients requiring supplementary MRI sequences of anterior cruciate ligament (ACL) tears, without a supervising radiologist. Methods: The study had ethical approval and two hundred and thirty one consecutive prospective MRI patients with mechanical knee symptoms (77 females, 154 males, of mean age 43.5, range 18–82 years) gave written informed consent. They then had a knee arthroscopy within seven days of the MRI. This was a pragmatic study to see if the six general MRI radiographers, each with over four years experience, could evaluate the ACL on routine orthogonal sequences (sagittal T1, Gradient Echo T2, Coronal STIR and axial fat suppressed dual echo). If they identified no ACL, then two 3D volume sequences (Dual Echo Steady State and Fast Low Angle Shot) and 2D limited sagittal oblique T1 sequences were also performed. Patients requiring extra sequences, missed by the radiographers, were recalled. The MRI sequences were independently evaluated in a blinded fashion by two consultant radiologists and a specialist radiology registrar and compared to the subsequent knee arthroscopy, as the gold standard, to determine the diagnostic performance statistics. Results: The cohort was on the knee arthroscopy weighting list and comprised 205 patients with chronic, 20 acute and 6 acute on chronic mechanical knee symptoms. There were no posterior cruciate, medial, or lateral collateral ligament tears at arthroscopy, used as the gold standard. The arthroscopy was normal and the radiographers correctly did not scan the extra sequence in 140 patients (72%) who then had normal arthroscopies. The radiographers did perform additional ACL sequences in 63 patients (27%). Of these, 10 patients had a partial and 12 complete ACL tears. Only two patients (0.9%) were recalled for additional

  11. Radiographic study of the hepatomegaly

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Soo [Busan National University College of Medicine, Pusan (Korea, Republic of)

    1980-06-15

    The author studied, with emphasis on the various radiographic projections, the 99 cases of liver enlargement, which underwent the barium meal upper gastrointestinal examinations for the purpose of pursuit of significance of liver enlargement and, at the same time were confirmed by other clinical and pathological methods at Busan National University Hospital for about 2 years from November 1977 to September 1979. The following results were obtained: 1. The incidence of liver enlargement was 63.3% (62 cases) in the 5th decade, which was most prevalent, 18.2% (18 cases) in the 3rd decade, 15.2% (15 cases) in the group over 60, and 3.0% (3 cases) in the age group below 20. Male to female sex ratio was 2 : 1. 2. The causes of the liver enlargement confirmed by the final diagnosis are as follows: Primary hepatic cancer 39 cases (39.3%), liver cirrhosis 30 cases (30.3%), chronic hepatitis 12 cases (12.1%), cancer of the biliary tract 6 cases (6.1%), hepatic fluke 6 cases (6.1%), metastatic tumors 3 cases (3.0%), and hepatic congestion 3 cases (3.0%) 3. In the prone view, the displacement of the duodenal bulb appeared in 18 cases (18.2%). 4. In the routine radiographs, the displacement of the stomach to the left and the pressure indentation of the lesser curvature were noted in 69 cases (69.7%) out of 99 cases. 5.In the left lateral recumbent view, the pressure indentation of the anterior border of the gastric body was seen in 96 cases (97.0%) among the 99 cases, the straightening in 30 cases (27.3%), the marked depression in 30 cases (30.3%), the moderate in 27 cases (27.3%), the minimal in 9 cases (9.1%). 6. Comparing the incidences of the roentgen findings of the liver enlargement in the various projections respectively, the displacement of the duodenal bulb was noted in 18 cases (18.3%) in the prone position. The erect position revealed the displacement of the stomach to the left and the pressure indentation in 57 cases (57.6%), the prone position in 51 cases (51

  12. Variations in the accessory structures of the clavicle: findings at chest radiographs and dry bones

    International Nuclear Information System (INIS)

    Chung, Min Suk; Suh, Kyung Jin; Joo, Kang; Chung, In Hyuk

    1995-01-01

    To evaluate normal variations and thus to avoid confusion in differentiation from lesions of the accessory structures (rhomboid fossa, foramen for supraclavicular nerve, conoid tubercle) of the clavicle in chest radiographs. We studied the variations of the clavicle in 300 chest radiographs (134 men, 166 women) and 355 dry bones (right 166, left 189;151 men, 74 women, 130 unknown sex). In chest radiographs, the incidence of the depressed rhomboid fossa was 229 cases (39.5%; male 52.0%, female 29.9%); the flat type was 329 cases (56.9%; male 45.7%, female 65.7%); and the elevated type was 20 cases (3.5%;male 2.4%, female 4.3%). In the dry bones, the incidence of the depressed rhomboid fossa was 129 cases (57.3%; male 59.6%, female 52.7%); the flat type was 65 cases (28.9%; male 24.5%, female 37.8%); and the elevated type was 31 cases (13.8%; male 15.9%, female 9.5%). The incidence of the foramen for supraclavicular nerve was 0.8% in chest radiographs, and 1.4% in the dry bones. The incidence of the elevated conoid tubercle was 65.1% (male 64.0%, female 65.9%) in chest radiographs, and 96.9% (male 95.4%, female 100.0%) in the dry bones. The incidence of the depressed rhomboid fossa in chest radiographs was higher in men and the right clavicle. The incidence of flat rhomboid fossa in chest radiographs decreased according to increase of age. The foramen for supraclavicular nerve was occasionally found ( 0.8% in chest radiographs; 1.4% in the dry bones)

  13. Chest radiographic staging in allergic bronchopulmonary aspergillosis: relationship with immunological findings.

    LENUS (Irish Health Repository)

    Kiely, J L

    2012-02-03

    The question of whether a chest radiographic severity staging system could be correlated with standard blood\\/serum diagnostic indices in allergic bronchopulmonary aspergillosis (ABPA) was addressed in 41 patients. Asthma and positive Aspergillus fumigatus (AF) serology were considered essential diagnostic inclusion criteria. Eosinophil count, serum immunoglobulin (Ig)E and immediate skin hypersensitivity were also tested to grade patients as "definite" or "likely" ABPA. Definite cases had all five of these factors present, whereas likely cases had three or more. Chest radiographs were examined by experienced radiologists blinded to the clinical data. The six-stage radiographic score (0-5) was based on the severity and duration of changes seen: stage 0: normal; stage 1: transient hyperinflation; stage 2: transient minor changes; stage 3: transient major changes; stage 4: permanent minor changes; and stage 5: permanent major changes. Significant positive correlations (p<0.05) were observed between peak AF titres (expressed as an index), peak eosinophil count and radiographic severity stage. When considered as subgroups, these correlations approached, but did not reach, significance for the group with "likely" ABPA (n=28), but in the group with definite ABPA (n=13), there was a high correlation between radiographic score and peak AF index (r=0.59), as well as peak eosinophil count (r=0.62). This study suggests that the peak Aspergillus fumigatus index and eosinophil counts correlate best with the severity of radiographic stages in allergic bronchopulmonary aspergillosis. This chest radiographic staging system may be useful in the clinical assessment and management of patients with allergic bronchopulmonary aspergillosis, particularly in those patients with more severe radiographic stages.

  14. Consultant radiographer leadership - A discussion

    Energy Technology Data Exchange (ETDEWEB)

    Hogg, Peter [Directorate of Radiography, University of Salford, Allerton Building, Frederick Road, Salford, Greater Manchester M6 6PU (United Kingdom)], E-mail: p.hogg@salford.ac.uk; Hogg, Dianne [Henwood Associates (South East) Ltd, Company Number: 513796, Registered Office: 2 Lakeview Stables, Lower St Clere, Kemsing, Kent, TN15 6NL (United Kingdom); Henwood, Suzanne [East Lancashire Primary Care Trust, Linden Business Centre, Linden Road, Colne. BB8 9BA (United Kingdom)

    2008-12-15

    Effective leadership can be defined in many ways and is an essential element of successful organisations; poor leadership can result in problems such as low staff morale, high staff turnover and reduced productivity. Effective leadership behaviours are well documented in the literature and various leadership models have been proposed that illustrate these behaviours. This discussion paper does not focus on any particular model. Instead it considers the 'Leadership Qualities Framework' which was developed specifically for use within the UK National Health Service. This framework draws upon a range of leadership models and as such it gives a broad indication of leadership behaviours. The framework comprises three components - 'personal qualities', 'setting direction' and 'delivering the service'. This paper commences with an argument as to why effective leadership is important in organisations generally, and specifically within healthcare organisations. Various examples of leadership are illustrated from within and outside the NHS in order to demonstrate effective leadership behaviours. The Leadership Qualities Framework is then examined, along with scenarios to illustrate effective leadership behaviours in context (i.e. within a healthcare organisation). Subsequent reflections on the scenarios aim to identify leadership behaviours that are explained within the framework. The final element of this paper draws on [limited] published evidence of where consultant radiographers have demonstrated effective leadership behaviours. In this section the published evidence is examined and reflected upon. At the end of the article we indicate additional reading for those who wish to further develop their theoretical and practical leadership skills.

  15. Early characteristic radiographic changes in mucolipidosis II

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Lillian M. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); Lachman, Ralph S. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); University of California, International Skeletal Dysplasia Registry, Los Angeles, CA (United States)

    2016-11-15

    Although mucolipidosis type II has similar metabolic abnormalities to those found in all the mucopolysaccharidoses and mucolipidoses, there are distinctive diagnostic radiographic changes of mucolipidosis II in the perinatal/newborn/infant period. To describe the early characteristic radiographic changes of mucolipidosis II and to document when these changes manifest and resolve. We retrospectively reviewed radiographs and clinical records of 19 cases of mucolipidosis II from the International Skeletal Dysplasia Registry (1971-present; fetal age to 21/2 years). A radiologist with special expertise in skeletal dysplasias evaluated the radiographs. The most common abnormalities were increased vertebral body height (80%, nonspecific), talocalcaneal stippling (86%), periosteal cloaking (74%) and vertebral body rounding (50%). Unreported findings included sacrococcygeal sclerosis (54%) and vertebral body sclerosis (13%). Rickets and hyperparathyroidism-like (pseudohyperparathyroidism) changes (rarely reported) were found in 33% of cases. These changes invariably started in the newborn period and resolved by 1 year of age. The conversion from these early infantile radiographic features to dysostosis multiplex changes occurred in 41% of cases, and within the first year after birth. Several findings strongly suggest the diagnosis of mucolipidosis II, including cloaking in combination with one or more of the following radiographic criteria: talocalcaneal stippling, sacrococcygeal or generalized vertebral body sclerosis, vertebral body rounding, or rickets/hyperparathyroidism-like changes in the perinatal/newborn/infancy period. These findings are not found in the other two forms of mucolipidosis nor in any of the mucopolysaccharidoses. (orig.)

  16. Early characteristic radiographic changes in mucolipidosis II

    International Nuclear Information System (INIS)

    Lai, Lillian M.; Lachman, Ralph S.

    2016-01-01

    Although mucolipidosis type II has similar metabolic abnormalities to those found in all the mucopolysaccharidoses and mucolipidoses, there are distinctive diagnostic radiographic changes of mucolipidosis II in the perinatal/newborn/infant period. To describe the early characteristic radiographic changes of mucolipidosis II and to document when these changes manifest and resolve. We retrospectively reviewed radiographs and clinical records of 19 cases of mucolipidosis II from the International Skeletal Dysplasia Registry (1971-present; fetal age to 21/2 years). A radiologist with special expertise in skeletal dysplasias evaluated the radiographs. The most common abnormalities were increased vertebral body height (80%, nonspecific), talocalcaneal stippling (86%), periosteal cloaking (74%) and vertebral body rounding (50%). Unreported findings included sacrococcygeal sclerosis (54%) and vertebral body sclerosis (13%). Rickets and hyperparathyroidism-like (pseudohyperparathyroidism) changes (rarely reported) were found in 33% of cases. These changes invariably started in the newborn period and resolved by 1 year of age. The conversion from these early infantile radiographic features to dysostosis multiplex changes occurred in 41% of cases, and within the first year after birth. Several findings strongly suggest the diagnosis of mucolipidosis II, including cloaking in combination with one or more of the following radiographic criteria: talocalcaneal stippling, sacrococcygeal or generalized vertebral body sclerosis, vertebral body rounding, or rickets/hyperparathyroidism-like changes in the perinatal/newborn/infancy period. These findings are not found in the other two forms of mucolipidosis nor in any of the mucopolysaccharidoses. (orig.)

  17. Radiographic manifestations of arthritis in AIDS patients

    International Nuclear Information System (INIS)

    Rosenberg, Z.S.; Norman, A.; Solomon, G.

    1988-01-01

    The purpose of this study is to familiarize the radiologist with a newly discovered association between arthritis and acquired immunodeficiency syndrome (AIDS). The authors retrospectively reviewed the clinical and radiographic findings in 31 patients with human immunodeficiency virus (HIV) infection referred to their rheumatology clinic with musculoskeletal complaints. The patients carried a wide range of clinical diagnosis including Reiter syndrome, psoriatic arthritis, undifferentiated seronegative arthritis, isolated enthesopathies, rheumatoid arthritis and osteonecrosis. Radiographs were available in 24 of the 31 patients, and in 20 they showed radiographic features of arthritis, which included soft-tissue swelling periarticular osteoporosis, synovial effusions, sacroiliitis, periosteal reaction, joint space narrowing, marginal erosions, and osteonecrosis. Although the radiographic abnormalities were frequently mild, they were significant, given the short duration of disease in many of their patients (weeks to months) at the time radiographs were obtained. The range of radiographic findings in their series was varied and paralleled the wide range of clinical diagnoses. No findings were pathognomonic for HIV-associated arthritis. Nevertheless, HIV infection needs to be considered in any patient belonging to a recognized risk group who presents with musculoskeletal disease. This is particularly important since immunosupressive drugs used for the treatment of arthritis can be detrimental to patients with HIV infection

  18. Radiation protection education and training of radiographers

    International Nuclear Information System (INIS)

    Elsakkers, P.

    1995-01-01

    The International Society of Radiographers and Radiological Technicians (ISRRT) is an international non-governmental organisation in official relationship with the World Health Organization. Over 50 countries are members of the ISRRT. The ISRRT encourages and facilitates communication between radiographers throughout the world. The ISRRT has produced several documents, e.g. ''The Role of the Radiographer in Europe''. The ISRRT has also done research and developed initiatives to analyse the quality of training of radiographers in the different member states of the EC. Research was done in the member states to analyse the efforts in the field of quality control. An extended study was performed on the current level of education in radiation protection in the European member states. The ICRP recommends in its publications the need of good training and continuing education for all radiographers. An important part of the basic training of radiographers should focus on the performance of radiation protection and quality control tests. Good daily practice can decrease patient dose in many ways. (Author)

  19. A radiographic study of pediatric ulnar anatomy.

    Science.gov (United States)

    Cravino, Mattia; Oni, Julius K; Sala, Debra A; Chu, Alice

    2014-01-01

    The adult ulna has a unique bony architecture that has been described in the literature, but, to the best of our knowledge, the ulnar anatomy in children has not been described. We examined 75 anteroposterior (AP) and 64 lateral radiographs (29 were bilateral) of 50, 0.5- to 11-year-old, healthy children's forearms. On AP radiographs, the total ulnar length, the ulnar proximal angle, the ulnar distal angle, and the distance between each angle from the tip of the triceps insertion; and, on lateral radiographs, the ulnar length and bow deviation were measured. The correlation between age and radiographic measurements, differences based on sex, differences compared with adults' measurements, and interobserver/intraobserver reliability were assessed. Age had a very strong/strong positive correlation with length/distance measurements on both AP and lateral radiographs. Only AP ulnar distal angle was significantly different between sexes (females > males). Compared with the adult ulnar studies, the AP proximal angle in children is significantly smaller and the location of this angle is significantly more distal. Interobserver and intraobserver reliability were very good for length/distance measurements on AP and lateral radiographs. The knowledge of pediatric ulnar anatomy could be helpful in the treatment of forearm deformities due to multiple hereditary exostosis and osteogenesis imperfecta, and in the treatment of ulnar fractures, particularly in Monteggia variants, where restoration of the correct forearm anatomy is essential to obtain good clinical and functional results. Study of diagnostic test, Level II.

  20. Novel Influenza A (H1N1) Virus Infection in Children: Chest Radiographic and CT Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Min Jeong; Lee, Young Seok; Lee, Jee Young; Lee, Kun Song [Dankook University College of Medicine, Dankook University Hospital, Cheonan (Korea, Republic of)

    2010-12-15

    The purpose of this study was to evaluate the chest radiographic and CT findings of novel influenza A (H1N1) virus infection in children, the population that is more vulnerable to respiratory infection than adults. The study population comprised 410 children who were diagnosed with an H1N1 infection from August 24, 2009 to November 11, 2009 and underwent chest radiography at Dankook University Hospital in Korea. Six of these patients also underwent chest CT. The initial chest radiographs were classified as normal or abnormal. The abnormal chest radiographs and high resolution CT scans were assessed for the pattern and distribution of parenchymal lesions, and the presence of complications such as atelectasis, pleural effusion, and pneumomediastinum. The initial chest radiograph was normal in 384 of 410 (94%) patients and abnormal in 26 of 410 (6%) patients. Parenchymal abnormalities seen on the initial chest radiographs included prominent peribronchial marking (25 of 26, 96%), consolidation (22 of 26, 85%), and ground-glass opacities without consolidation (2 of 26, 8%). The involvement was usually bilateral (19 of 26, 73%) with the lower lung zone predominance (22 of 26, 85%). Atelectasis was observed in 12 (46%) and pleural effusion in 11 (42%) patients. CT (n = 6) scans showed peribronchovascular interstitial thickening (n = 6), ground-glass opacities (n = 5), centrilobular nodules (n = 4), consolidation (n = 3), mediastinal lymph node enlargement (n = 5), pleural effusion (n = 3), and pneumomediastinum (n = 3). Abnormal chest radiographs were uncommon in children with a swine-origin influenza A (H1N1) virus (S-OIV) infection. In children, H1N1 virus infection can be included in the differential diagnosis, when chest radiographs and CT scans show prominent peribronchial markings and ill-defined patchy consolidation with mediastinal lymph node enlargement, pleural effusion and pneumomediastinum

  1. Novel Influenza A (H1N1) Virus Infection in Children: Chest Radiographic and CT Evaluation

    International Nuclear Information System (INIS)

    Choi, Min Jeong; Lee, Young Seok; Lee, Jee Young; Lee, Kun Song

    2010-01-01

    The purpose of this study was to evaluate the chest radiographic and CT findings of novel influenza A (H1N1) virus infection in children, the population that is more vulnerable to respiratory infection than adults. The study population comprised 410 children who were diagnosed with an H1N1 infection from August 24, 2009 to November 11, 2009 and underwent chest radiography at Dankook University Hospital in Korea. Six of these patients also underwent chest CT. The initial chest radiographs were classified as normal or abnormal. The abnormal chest radiographs and high resolution CT scans were assessed for the pattern and distribution of parenchymal lesions, and the presence of complications such as atelectasis, pleural effusion, and pneumomediastinum. The initial chest radiograph was normal in 384 of 410 (94%) patients and abnormal in 26 of 410 (6%) patients. Parenchymal abnormalities seen on the initial chest radiographs included prominent peribronchial marking (25 of 26, 96%), consolidation (22 of 26, 85%), and ground-glass opacities without consolidation (2 of 26, 8%). The involvement was usually bilateral (19 of 26, 73%) with the lower lung zone predominance (22 of 26, 85%). Atelectasis was observed in 12 (46%) and pleural effusion in 11 (42%) patients. CT (n = 6) scans showed peribronchovascular interstitial thickening (n = 6), ground-glass opacities (n = 5), centrilobular nodules (n = 4), consolidation (n = 3), mediastinal lymph node enlargement (n = 5), pleural effusion (n = 3), and pneumomediastinum (n = 3). Abnormal chest radiographs were uncommon in children with a swine-origin influenza A (H1N1) virus (S-OIV) infection. In children, H1N1 virus infection can be included in the differential diagnosis, when chest radiographs and CT scans show prominent peribronchial markings and ill-defined patchy consolidation with mediastinal lymph node enlargement, pleural effusion and pneumomediastinum

  2. Heart regeneration.

    Science.gov (United States)

    Breckwoldt, Kaja; Weinberger, Florian; Eschenhagen, Thomas

    2016-07-01

    Regenerating an injured heart holds great promise for millions of patients suffering from heart diseases. Since the human heart has very limited regenerative capacity, this is a challenging task. Numerous strategies aiming to improve heart function have been developed. In this review we focus on approaches intending to replace damaged heart muscle by new cardiomyocytes. Different strategies for the production of cardiomyocytes from human embryonic stem cells or human induced pluripotent stem cells, by direct reprogramming and induction of cardiomyocyte proliferation are discussed regarding their therapeutic potential and respective advantages and disadvantages. Furthermore, different methods for the transplantation of pluripotent stem cell-derived cardiomyocytes are described and their clinical perspectives are discussed. This article is part of a Special Issue entitled: Cardiomyocyte Biology: Integration of Developmental and Environmental Cues in the Heart edited by Marcus Schaub and Hughes Abriel. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Continuous NSAID use reverts the effects of inflammation on radiographic progression in patients with ankylosing spondylitis

    NARCIS (Netherlands)

    Kroon, Féline; Landewé, Robert; Dougados, Maxime; van der Heijde, Désirée

    2012-01-01

    The aim was to compare continuous and on-demand NSAID treatment with respect to their ability to suppress radiographic progression in subgroups of patients with high/elevated CRP-levels, ESR, ASDAS-levels or BASDAI-levels in comparison to patients with normal levels. Post-hoc analyses were performed

  4. Radiographic and pathologic features of osteopetrosis in two Peruvian Paso foals

    International Nuclear Information System (INIS)

    Berry, C.R.; House, J.K.; Poulos, P.P.; Madigan, J.E.; Woodard, J.C.; Pool, R.R.; O'Brien, T.R.; Ackerman, N.

    1994-01-01

    The radiographic and pathologic findings of two Peruvian Paso foals with osteopetrosis are described. Both foals, one male and one female, presented with respiratory difficulty, brachygnathia and failure to rise after birth. Both foals were mildly anemic, hypogammaglobulinemic and had elevations in serum alkaline phosphatase. Increased medullary bone opacity was noted on radiographs of the extremities, spine and skull in both foals. A lack of normal cortical:medullary bone distinction was evident radiographically. The medullary primary spongiosa appeared to run in parallel columns away from the physes of all long bones and the vertebrae. This created a distinctive hour glass appearance to the osteopetrotic bones. One foal developed a bacterial pneumonia. Both foals were euthanized due to failure to thrive. Histopathology and electron microscopy documented these foals to have normal osteoclastic numbers but lack normal ruffled borders, lack of a clear zone and normal lysosomal numbers indicative of cellular dysfunction. These clinical, radiographic and pathologic findings are similar to the juvenile, lethal autosomal recessive form of osteopetrosis described in humans. Osteopetrosis has not been previously described in a female foal

  5. Reliability of early radiographic evaluations for canine hip dysplasia obtained from the standard ventrodorsal radiographic projection

    International Nuclear Information System (INIS)

    Corley, E.A.; Keller, G.G.; Lattimer, J.C.; Ellersieck, M.R.

    1997-01-01

    To determine reliability of preliminary evaluations for canine hip dysplasia (CHD) performed by the Orthopedic Foundation for Animals on dogs between 3 and 18 months of age. Retrospective analysis of data from the Orthopedic Foundation for Animals database. 2,332 Golden Retrievers, Labrador Retrievers, German Shepherd Dogs, and Rottweilers for which preliminary evaluation had been performed between 3 and 18 months of age and for which results of a definitive evaluation performed after 24 months of age were available. Each radiograph was evaluated, and hip joint status was graded as excellent, good, fair, or borderline phenotype or mild, moderate, or severe dysplasia. Preliminary evaluations were performed by 1 radiologist; definitive evaluations were the consensus of 3 radiologists. Reliability of preliminary evaluations was calculated as the percentage of definitive evaluations (normal vs dysplastic) that were unchanged from preliminary evaluations. Reliability of a preliminary evaluation of normal hip joint phenotype decreased significantly as the preliminary evaluation changed from excellent (100%) to good (97.9%) to fair (76.9%) phenotype. Reliability of a preliminary evaluation of CHD increased significantly as the preliminary evaluation changed from mild (84.4%) to moderate (97.4%) CHD. Reliability of preliminary evaluations increased significantly as age at the time of preliminary evaluation increased, regardless of whether dogs received a preliminary evaluation of normal phenotype or CHD. Results suggest that preliminary evaluations of hip joint status in dogs are generally reliable. However, dogs that receive a preliminary evaluation of fair phenotype of mild CHD should be reevaluated after 24 months of age

  6. Mycoplasma pneumonia in children: radiographic pattern analysis and difference in resolution

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Myeong Ja; Jeong, Sung Eun; Kim, Joung Sook; Hur, Gham; Park, Jeung Uk [Inje Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-11-01

    By analysing frequency and disease progression, this study aimed to investigate and predict the prognosis of mycoplasma pneumonia according to radiographic pattern. We retrospectively reviewed plain chest radiographs of 230 patients in whom mycoplasm pneumonia had been serologically confirmed. Their age ranged from two months to 14 years and two months, and 203(88.3%) were younger than eight years. Radiographic patterns were classified as air space consolidation, bronchopneumonic, interstitial pneumonic or diffuse mixed infiltrating type. The radiologic resolution period for each type was analysed by the resolution of symptoms and normalization of radiologic findings. The bronchopneumonic type, which was the most common, was seen in 82 patients(35.6%), airspace consolidation in 58(25.2%), interstitial in 55(23.9%), and diffuse mixed in 22(9.57%). In thirteen patients(5.7%), chest radiographs were normal, though the clinical and radiologic resolution period for each type was variable. The mean resolution period of the air space consolidation type was 14.5 days, bronchopneumonic, 7.6 days ; interstitial, 10.5 days, and diffuse mixed, 15.6 days. The airspace consolidation type needed the longest recovery period, exceeded only by the diffuse mixed type. The bronchopneumonic type was the most common radiographic pattern of mycoplasma pneumonia. The prognosis of the airspace consolidation type seems to be poorest, since this required the longest recovery period.

  7. Pinhole bone scan mapping of metabolic profiles in osteoarthritis of the knee: a radiographic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. H.; Kim, H. H.; Chung, Y. A.; Chung, S. K.; Bahk, Y. W. [College of Medicine, The Catholic Univ. of Korea, Seoul (Korea, Republic of)

    1999-07-01

    Osteoarthritis (OA) is mixture of damage to a joint and reaction induced therefrom. Heterogeneity, slow change and no proper means of assessing pathology make it a difficult disease to study. Diagnosis can be made by radiography when OA is established. But subtle metabolic change without radiographic alteration can only be detected by bone scan. Present study was performed to assess metabolic profiles of OA of the knee with various radiographic and preradiographic changes using pinhole bone scan (PBS). PBS and radiography were taken at the same time or a few days apart. We used single-head gamma camera and a 4-mm pinhole collimator. Patients were 9 men and 19 women (30-74 yr with mean being 55). PBS was correlated with radiography in each case. Increased tracer uptake was seen in 111 lesions in 28 knees. Intensity was arbitrarily graded into Grade 0-2. The results were divided into group with radiographic change (n=85; Table) and group without (n=26). Generally, tracer uptake was much intense in the sclerotic and cystic form. In radiographically normal group pathological uptake occurred mostly in subchondral bone (n=17) and some in the femoral condyle (n=9) denoting that subchondral bone is the most vulnerable. PBS is sensitive indicator of metabolic alternations in various disease processes of OA in both radiographically normal and abnormal cases.

  8. Heart Failure

    OpenAIRE

    McMurray, John; Ponikowski, Piotr

    2011-01-01

    Heart failure occurs in 3% to 4% of adults aged over 65 years, usually as a consequence of coronary artery disease or hypertension, and causes breathlessness, effort intolerance, fluid retention, and increased mortality. The 5-year mortality in people with systolic heart failure ranges from 25% to 75%, often owing to sudden death following ventricular arrhythmia. Risks of cardiovascular events are increased in people with left ventricular systolic dysfunction (LVSD) or heart failure.

  9. Artificial heart

    Energy Technology Data Exchange (ETDEWEB)

    1984-10-18

    Super-pure plutonium-238 could use heat produced during fission to power an implanted artificial heart. Three model hearts have worked for some time. Concern that excess heat would make the procedure unsafe for humans has broadened the search for another energy source, such as electrohydraulic drive or an external power battery. A back pack approach may provide an interim solution until materials are developed which can withstand heart activity and be small enough for implantation.

  10. Radiochemicals used to scan the heart

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Techniques for heart scanning using 201 Tl and /sup 99m/Tc pyrophosphate are discussed. Thallium-201, produced artificially in a cyclotron, concentrates in normal heart muscle but not in abnormal tissue. Technetium-99m is deposited in mitochondria of heart cells that are irreversibly damaged. The combined use of 201 Tl and /sup 99m/Tc makes it possible to identify regions of recent heart damage as well as older heart damage. Advantages of using 129 Cs for heart scanning are also discussed

  11. Types of Heart Failure

    Science.gov (United States)

    ... Introduction Types of Heart Failure Classes of Heart Failure Heart Failure in Children Advanced Heart Failure • Causes and ... and procedures related to heart disease and stroke. Heart Failure Questions to Ask Your Doctor Use these questions ...

  12. Nuclear magnetic resonance imaging of the heart

    International Nuclear Information System (INIS)

    Smolorz, J.; Linden, A.; Schicha, H.; Sechtem, U.

    1988-01-01

    NMR imaging is a noninvasive technique that has been shown to provide high-quality images of the heart. Due to the signal characteristics of flowing blood, inherent contrast between blood pool and myocardium is achieved without the use of contrast media. This paper briefly describes technical aspects of NMR imaging of the heart, normal cardiovascular anatomy, applications of the technique in patients with ischemic heart disease, and the potential of NMR imaging for functional studies in various forms of heart disease. (orig.)

  13. Mammography manual for the daily routine. A technical, practical and quality guide for radiologists, gynaecologists and radiographers

    International Nuclear Information System (INIS)

    Roth-Ganter, G.; Fischer, U.

    2002-01-01

    Gudrun Roth-Ganther presents in this book a wealth of professional experience that she has been accumulating over many years as a radiographer tutor at home and abroad. Step by step the reader will learn how to make high-quality mammographs. Important aspects: the normal radiographic anatomy of the mamma, factors influencing the image quality, technical parameters, exposure techniques, approaches for quality assessment and quality assurance, detecting and avoiding mistakes. (orig./CB) [de

  14. Radiographic features of teriparatide-induced healing of femoral fractures

    Directory of Open Access Journals (Sweden)

    Youngwoo Kim

    2015-12-01

    Full Text Available Teriparatide is a drug that is used to increase bone remodeling, formation, and density for the treatment of osteoporosis. We present three cases of patients with a femoral insufficiency fracture. The patients were administered teripatatide in an attempt to treat severe osteoporosis and to enhance fracture healing. We found several radiographic features around the femoral fractures during the healing period. 1 Callus formation was found at a very early stage in the treatment. Teriparatide substantially increased the unusually abundant callus formation around the fracture site at 2 weeks. Moreover, this callus formation continued for 8 weeks and led to healing of the fracture. 2 Abundant callus formation was found circumferentially around the cortex with a ‘cloud-like’ appearance. 3 Remodeling of the teriparatide-induced callus formation was found to be part of the normal fracture healing process. After 1 year, normal remodeling was observed on plain radiographs. These findings indicate that teriparatide can be used as an adjuvant therapy in the management of femoral insufficiency fractures.

  15. CT and MRI normal findings

    International Nuclear Information System (INIS)

    Moeller, T.B.; Reif, E.

    1998-01-01

    This book gives answers to questions frequently heard especially from trainees and doctors not specialising in the field of radiology: Is that a normal finding? How do I decide? What are the objective criteria? The information presented is three-fold. The normal findings of the usual CT and MRI examinations are shown with high-quality pictures serving as a reference, with inscribed important additional information on measures, angles and other criteria describing the normal conditions. These criteria are further explained and evaluated in accompanying texts which also teach the systematic approach for individual picture analysis, and include a check list of major aspects, as a didactic guide for learning. The book is primarily intended for students, radiographers, radiology trainees and doctors from other medical fields, but radiology specialists will also find useful details of help in special cases. (orig./CB) [de

  16. Radiographic and Clinical Analysis of Lateral Epicondylitis.

    Science.gov (United States)

    Shillito, Matthew; Soong, Maximillian; Martin, Nicholas

    2017-06-01

    The literature suggests that radiographs may be unnecessary in the initial evaluation of lateral epicondylitis because treatment is rarely altered as a result of the radiographic findings. The most commonly reported radiographic finding is calcification at the lateral epicondyle. Our goal was to perform a quantitative and qualitative analysis of this finding to determine its importance and possible relationship with various clinical factors and patient-reported measures. All patients diagnosed with lateral epicondylitis by a single surgeon during a 5-year period were retrospectively reviewed. Age, sex, laterality, hand dominance, pain visual analog scale, duration of symptoms, Quick-Disability of the Arm, Shoulder, and Hand questionnaire score, and history of steroid injection were recorded. Calcifications on standard elbow radiographs, acquired digitally and viewed at 200% magnification on a 24-inch monitor, were characterized by size and relationship with the lateral epicondyle. We reviewed 245 patients diagnosed with lateral epicondylitis. A total of 115 elbows (47%) demonstrated lateral epicondyle calcifications. Patients with and without calcifications were similar with regard to clinical factors, as were patients with larger or smaller lesions. Eighty-five elbows (35%) had additional radiographic findings. Treatment was not altered by the radiographic findings in any case. Lateral epicondyle calcifications are much more common in lateral epicondylitis than previously reported, possibly owing to modern digital radiography and magnification, although they do not appear to be related to clinical factors including patient-reported measures. Thus, patients and surgeons should be careful to avoid overinterpretation of such findings. Although radiographs may be helpful in ruling out additional pathology, we did not find other clinically important contributions to the initial evaluation and management of this condition, and thus we do not recommend their routine use

  17. Australian rural radiographers' perspectives on disclosure of their radiographic opinion to patients

    International Nuclear Information System (INIS)

    Squibb, Kathryn; Bull, Rosalind M.; Smith, Anthony; Dalton, Lisa

    2015-01-01

    The role of Australian rural radiographers in radiographic interpretation, communication and disclosure of their radiographic opinion with a specific focus on plain film radiography was examined in a two phase, exploratory interpretive study. Data were collected using questionnaires and interviews and analysed thematically. This reports one of the key themes identified in the thematic data analysis. ‘Disclosure of Radiographic Opinion to Patients’ comprises the three interrelated sub-themes Acting Ethically, Selective Disclosure and Filtered Truth. It is wholly concerned with the ways in which rural radiographers choose to disclose their radiographic opinion to patients. Without a clear picture of where they stand medico-legally, rural radiographers draw on experience and a strong ethical framework as the basis for these complex decisions. Rural radiographers frame their disclosures to patients in a manner that is governed by the diagnostic, therapeutic and emotional impact the information disclosed may have on the patient. Disclosure to patients was found to be selective, often diagnostically vague and ethically filtered

  18. Radiographic testing - optimum radiographs of plastics and composite materials with dosimeter control

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wavelength radiation corresponding 10 to 25 kV.P. (orig.) [de

  19. Transthoracic lung ultrasound in normal dogs and dogs with cardiogenic pulmonary edema: a pilot study.

    Science.gov (United States)

    Rademacher, Nathalie; Pariaut, Romain; Pate, Julie; Saelinger, Carley; Kearney, Michael T; Gaschen, Lorrie

    2014-01-01

    Pulmonary edema is the most common complication of left-sided heart failure in dogs and early detection is important for effective clinical management. In people, pulmonary edema is commonly diagnosed based on transthoracic ultrasonography and detection of B line artifacts (vertical, narrow-based, well-defined hyperechoic rays arising from the pleural surface). The purpose of this study was to determine whether B line artifacts could also be useful diagnostic predictors for cardiogenic pulmonary edema in dogs. Thirty-one normal dogs and nine dogs with cardiogenic pulmonary edema were prospectively recruited. For each dog, presence or absence of cardiogenic pulmonary edema was based on physical examination, heartworm testing, thoracic radiographs, and echocardiography. A single observer performed transthoracic ultrasonography in all dogs and recorded video clips and still images for each of four quadrants in each hemithorax. Distribution, sonographic characteristics, and number of B lines per thoracic quadrant were determined and compared between groups. B lines were detected in 31% of normal dogs (mean 0.9 ± 0.3 SD per dog) and 100% of dogs with cardiogenic pulmonary edema (mean 6.2 ± 3.8 SD per dog). Artifacts were more numerous and widely distributed in dogs with congestive heart failure (P dogs. © 2014 American College of Veterinary Radiology.

  20. The importance of plain radiographic signs for emergency aortography in blunt chest trauma

    International Nuclear Information System (INIS)

    Schumacher, K.A.; Trost, K.; Bargon, G.

    1983-01-01

    A retrospective study of plain radiographic findings in 11 patients with traumatic rupture of the aorta was conducted, and the results compared with the incidence of numerous chest x-rays signs previously described in 294 cases of angiographically proven thoracic aorta dissection. It is concluded that positive plain radiographic signs obtained from patients with blunt chest trauma reveal high sensitivity and may thus be used as an indication for emergency aortography. However, since this procedure lacks 100% specificity even those patients with normal x-ray findings but clinically and/or anamnestically adequate thoracic trauma should be submitted to aortography. (orig.) [de

  1. Endocrine Disorders in Head Neck Region: A Radiographic Perspective in Dental Clinic

    Directory of Open Access Journals (Sweden)

    Aparna M

    2014-04-01

    Full Text Available Endocrine diseases may have manifestations locally or in a generalized manner. When an imbalance in normal bone homeostasis occurs, regulated by various hormones such as parathyroid hormone, growth hormone it results in conditions like hypercalcemia, hypophosphatemia etc. which may affect bone density in a generalized manner. The condition cause: excessive resorption of bone or excessive deposition of bone. Intraoral or extraoral radiographs are thus useful in detecting diseases like hyperparathyroidism, hyperpituitarism, hypoparathyroidism, and hypopituitarism which are subclinical and are detected accidently on routine radiographic examination.

  2. Radiographic study on temporomandibular joint Arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Dong Soo [Dept. of Radiology, College of Dentistry, Seoul National University , Seoul (Korea, Republic of)

    1980-11-15

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  3. Radiographic study on temporomandibular joint Arthrosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo

    1980-01-01

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  4. Radiographers' preconditions for evidence-based radiography

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari; Liikanen, Eeva

    2010-01-01

    Evidence-based practice (EBP) is essential in today's health care, but its establishment requires several preconditions from individuals and organizations (e.g. knowledge, understanding, attitudes, abilities, self-confidence, support, and resources). Previous studies suggest that radiographers do generate and use evidence in their work, but evidence-based radiography (EBR) is not yet used routinely as established practice, especially in terms of research utilization. This paper aims to describe radiographers' preconditions for EBR, and their participation in research activities. Main focus is on research utilization. Using an electronic questionnaire developed for this study, a survey was conducted: data collected from Finnish radiographers and radiotherapists (N = 438) were analysed both statistically and qualitatively. The final response rate was 39%. The results suggest radiographers' preconditions for EBR to consist of knowledge of research, significance of research activities, research-orientated way of working, and support. In addition, adequate resourcing is essential. Reading scientific journals, participation in research activities, a higher degree of education, and senior post seem to be significant promoters of EBR and research utilization. The results support the notion that EBR, and especially research utilization, are not yet well-established in Finland, and radiographers' viewpoints concerning the role and significance of research evidence and research activities still seem to vary.

  5. Radiographic evaluation of the diabetic foot

    International Nuclear Information System (INIS)

    Jacobs, A.M.

    1989-01-01

    Radiographic evaluation of the foot in the patient with diabetes mellitus is discussed in this paper. According to the author, it can only be of value when the soft tissue and bony and joint pathologic conditions, which occur more frequently in the diabetic patient are also considered and understood. Although not pathognomic for diabetes mellitus, neuroarthopathy, osteomyelitis, soft tissue infection, and some rheumatic disorders are present with greater frequency in diabetic populations than in non-diabetic populations. Frequently, edema, erythema, hyperthermia, and tenderness are present as nonspecific clinical findings, in which case radiographic evaluation is called upon to define the specific etiology of a particular patient's pathology. Unfortunately, many radiographic, computerized tomographic, and radionuclide studies demonstrate less than optimal positive and negative predictive values unless interpreted in view of clinical history and examination and integrated with the results of other laboratory data. Radiographic evaluation of the diabetic foot may be utilized to establish the presence of disease, the extent of pedal involvement, and the response to therapy. The establishment of the nature of disease processes from radiographic findings alone, however, may be problematic. The diagnosis of osteomyelitis, for example, rests on the recovery of the offending microorganisms from bone aspiration or culture

  6. Echocardiographic specrtrum of heart disease in a secondary ...

    African Journals Online (AJOL)

    HHD (58%) was the most common heart disease followed by dilated cardiomyopathy (7.4%) and valvular heart disease(6.1%).61(8.1%) subjects had normal echocardiogram. Conclusion:Hypertensive heart disease is the most common indication for echocardiography and also the predominant cause of heart disease in ...

  7. An investigation on comprehensive evaluation and standard of image quality of high voltage chest radiograph

    International Nuclear Information System (INIS)

    Yan Shulin; Li Shuopeng; Zhao Bo; Niu Yantao

    1998-01-01

    Purpose: Based on clinical diagnostic demand, patient irradiation dose and imaging technical parameters, to establish a comprehensive evaluation method and standard in chest radiograph. Methods: (1) From 10 normal chest radiographs, the authors selected the evaluation area on thoracic PA (posteroanterior) radiographs and set up standard for diagnostic demand; (2) Using chest CT scans of 20 males and 20 females, the authors calculated the ratio of lung field to mediastinum; (3) Selecting 100 chest films using 125 kVp, the authors measured the standard density values of each evaluation area; (4) Body surface irradiation doses of 478 normal adults were measured. Results: (1) Based on diagnostic demand, the authors confirmed 7 evaluation areas and 4 physical evaluation factors. At the same time, evaluation standards were obtained; (2) Comprehensive evaluation methods were established; (3) Standard height, weight and body surface irradiation dose of Chinese normal adults were investigated preliminarily. Conclusion: Based on the concept of comprehensive evaluation, investigation on the evaluation methods and standard in chest PA radiograph was carried out which might be taken as the foundation for future approach on nation-wide basis

  8. Are upright lateral cervical radiographs in the obtunded trauma patient useful? A retrospective study

    Directory of Open Access Journals (Sweden)

    Bolles Gene

    2007-02-01

    Full Text Available Abstract Background The best method for radiographic "clearance" of the cervical spine in obtunded patients prior to removal of cervical immobilization devices remains debated. Dynamic radiographs or MRI are thought to demonstrate unstable injuries, but can be expensive and cumbersome to obtain. An upright lateral cervical radiograph (ULCR was performed in selected patients to investigate whether this study could provide this same information, to enable removal of cervical immobilization devices in the multiple trauma patient. Methods We retrospectively reviewed our experience with ULCR in 683 blunt trauma victims who presented over a 3-year period, with either a Glasgow Coma Score Results ULCR was performed in 163 patients. Seven patients had studies interpreted to be abnormal, of which six were also abnormal, by either CT or MRI. The seventh patient's only abnormality was soft tissue swelling; MRI was otherwise normal. Six patients had ULCR interpreted as normal, but had abnormalities on either CT or MRI. None of the missed injuries required surgical stabilization, although one had a vertebral artery injury demonstrated on subsequent angiography. ULCR had an apparent sensitivity of 45.5% and specificity of 71.4%. Conclusion ULCR are inferior to both CT and MRI in the detection of cervical injury in patients with normal plain radiographs. We therefore cannot recommend the use of ULCR in the obtunded trauma patient.

  9. Acromioclavicular joint: Normal variation and the diagnosis of dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Keats, T.E.; Pope, T.L. Jr.

    1988-04-01

    Acromioclavicular separation is a common traumatic injury. Diagnosis rests on clinical and radiographic findings. However, normal variation in the alignment of the acromioclavicular joint may make the roentgen diagnosis more difficult. We stress the variations of normal alignment at the acromioclavicular joint and offer suggestions for avoiding pitfalls in this clinical situation.

  10. The acromioclavicular joint: Normal variation and the diagnosis of dislocation

    International Nuclear Information System (INIS)

    Keats, T.E.; Pope, T.L. Jr.

    1988-01-01

    Acromioclavicular separation is a common traumatic injury. Diagnosis rests on clinical and radiographic findings. However, normal variation in the alignment of the acromioclavicular joint may make the roentgen diagnosis more difficult. We stress the variations of normal alignment at the acromioclavicular joint and offer suggestions for avoiding pitfalls in this clinical situation. (orig.)

  11. Simple, heart-smart substitutions

    Science.gov (United States)

    Coronary artery disease - heart smart substitutions; Atherosclerosis - heart smart substitutions; Cholesterol - heart smart substitutions; Coronary heart disease - heart smart substitutions; Healthy diet - heart ...

  12. Radiographic findings in tuberculosis of the calvarium

    Energy Technology Data Exchange (ETDEWEB)

    Patankar, T.; Varma, R.; Krishnan, A.; Prasad, S. [Dept. of Radiology, King Edward Memorial Hospital, Parel, Bombay (India); Desai, K. [Dept. of Neurosurgery, King Edward Memorial Hospital, Bombay (India); Castillo, M. [Dept. of Radiology, University of North Carolina School of Medicine, Chapel Hill, NC (United States)

    2000-07-01

    We reviewed the pattern of involvement of the calvarium by tuberculosis (TB) in five patients and the role of imaging in its management. Four patients presented with localised scalp swelling and one with generalized seizures. Radiographs revealed lucent lesions with minimal surrounding sclerosis in the frontal (2), parietal (2) and occipital (1) bones. CT showed lesions involving the entire thickness of the calvarium and accompanying contrast-enhancing soft tissue. The patient presenting with seizures had a ring-enhancing lesion in the parietal lobe in addition to the extra-axial lesions. Although radiographs in all cases demonstrated calvarial TB, CT showed the extent of the defect, involvement of adjacent soft tissues, and in one case an intra-axial lesion. Radiographs suffice for follow-up of these patients. (orig.)

  13. Understanding chest radiographic anatomy with MDCT reformations

    Energy Technology Data Exchange (ETDEWEB)

    Sussmann, A.R. [Department of Radiology, Thoracic Imaging, NYU Langone Medical Center, New York, NY (United States); Ko, J.P., E-mail: jane.ko@nyumc.or [Department of Radiology, Thoracic Imaging, NYU Langone Medical Center, New York, NY (United States)

    2010-02-15

    Chest radiograph interpretation requires an understanding of the mediastinal reflections and anatomical structures. Computed tomography (CT) improves the learning of three-dimensional (3D) anatomy, and more recently multidetector CT (MDCT) technology has enabled the creation of high-quality reformations in varying projections. Multiplanar reformations (MPRs) of varying thickness in the coronal and sagittal projections can be created for direct correlation with findings on frontal and lateral chest radiographs, respectively. MPRs enable simultaneous visualization of the craniocaudal extent of thoracic structures while providing the anatomic detail that has been previously illustrated using cadaveric specimens. Emphasis will be placed on improving knowledge of mediastinal anatomy and reflections including edges, lines, and stripes that are visible on chest radiographs.

  14. Radiographic abnormalities in tricyclic acid overdose

    International Nuclear Information System (INIS)

    Varnell, R.M.; Richardson, M.L.; Vincent, J.M.; Godwin, J.D.

    1987-01-01

    Several case reports have described adult respiratory distress syndrome (ARDS) secondary to tricyclic acid (TCA) overdose. During a 1-year period 83 patients requiring intubation secondary to drug overdose were evaluated. Abnormalities on chest radiographs occurred in 26 (50%) of the 54 patients with TCA overdose, compared to six (21%) of the 29 patients overdosed with other drugs. In addition, five (9%) of the patients with TCA overdose subsequently had radiographic and clinical abnormalities meeting the criteria for ARDS. Only one (3%) of the patients with non-TCA overdose subsequently had change suggesting ARDS. TCAs should be added to the list of drugs associated with ARDS, and TCA overdose should be considered a major risk factor in the development of radiographically evident abnormalities

  15. Opportunistic esophagitis in AIDS: Radiographic diagnosis

    International Nuclear Information System (INIS)

    Levine, M.S.; Woldenberg, R.; Herlinger, H.; Laufer, I.

    1987-01-01

    Between 1983 and 1986, 35 of 90 patients with acquired immunodeficiency syndrome (AIDS) had double-contrast esophagograms to rule out opportunistic esophagitis. The radiographs were reviewed without knowledge of the clinical or endoscopic findings. Candida esophagitis was diagnosed radiographically in 17 patients who had varying degrees of plaque formation and viral esophagitis in three who had discrete ulcers without plaques. All three patients with viral esophagitis (herpes in 2 and cytomegalo virus in one) and 15 of 17 with Candida esophagitis had endoscopic and/or clinical corroboration of the radiographic diagnosis. Thus, the authors' experience suggests that fungal and viral esophagitis can often be differentiated on double-contrast esophagography, so that appropriate antifungal or antiviral therapy can be instituted without need for endoscopic intervention

  16. Development of low-silver radiographic detectors

    International Nuclear Information System (INIS)

    Troitskij, V.A.; Novikov, I.A.; Nikitin, V.F.; Krasnyj-Admoni, L.V.; Valevich, M.I.; Belyj, N.G.; Grom, V.S.

    1988-01-01

    The results of investigations on radiographic testing of welded joints of St20, 08Kh18N10T steels, the AMG-6 alloy, copper, titanium using radiographic detectors with the low silver content are presented. The roentgenographic and photographic paper, as well as the samples of experimental films with heavy elements in the photolayer are tested using intensifying screens of different types. Experimental films containing silver 2 times as less as standard X-ray films are shown to provide the similar sensitivity of testing under equal conditions, but the exposure time is two times higher. Prints on the radiophotographic paper in quality and exposure time approach to prints obtained on the RT-1 film containing silver 10 times less than that in the roentgenographic film. The exposure time of the radiographic paper is several times less than that of the ''unibrom'' contrast paper. The testing sensitivity decreases to some extent in this case

  17. Examination of the constancy of the medium optical density of conventional chest radiographs

    International Nuclear Information System (INIS)

    Stieve, F.E.; Rupp, N.; Niederhofer, F.; Gfirtner, H.

    2002-01-01

    Purpose: To determine whether the medium optical density of conventional chest radiographs is constant. Materials and Methods: 47 PA chest radiographs were digitized to measure the optical density and its dynamic range of normal and pathologically altered lungs. Results: For constant exposure factors and a correctly positioned region of interest, the medium optical density deviates only minimal despite differences in AP chest diameter, entry dose and dynamic range, and is largely independent of the pathologic pulmonary findings. Conclusion: Digitization of the radiograph enables the determination of the physical parameters used to operate the imaging system, such as medium optical density, image contrast, image latitude and density distribution, in accordance to the guidelines of the German Medical Association. If the region of interest encompasses the clinically relevant region of the lung, the measured value of the optical density corresponds with only minor variation to the average value of the entire lung region. (orig.) [de

  18. Reader performance in detection of pneumothorax on conventional chest films versus computed radiographs

    International Nuclear Information System (INIS)

    Elam, E.A.; Hillman, B.J.; Fajardo, L.L.

    1990-01-01

    This paper evaluates the suitability of digital radiography for the detection of pneumothoraces, we compared radiologist' performance in four interpretation settings: conventional film-screen (FS) chest radiographs; small-format (8 x 6.5-inch) computed radiography (CR) (Toshiba); large-format (14 x 17-inch) CR; and CR images viewed on a digital workstation. Twenty-three frontal-view chest radiographs with pneumothoraces and 22 other chest radiographs, either normal or showing miscellaneous abnormalities, were read by six board-certified radiologist in each interpretation setting. We compared the sensitivity, specificity, and receiver operating characteristic (ROC) performances they achieved among the interpretation settings with the use of sequential paired t tests. To date, four readers have completed their reading of both the FS and the small-format CR films

  19. Relationship of orthopedic examination, goniometric measurements, and radiographic signs of degenerative joint disease in cats.

    Science.gov (United States)

    Lascelles, B Duncan X; Dong, Yaa-Hui; Marcellin-Little, Denis J; Thomson, Andrea; Wheeler, Simon; Correa, Maria

    2012-01-27

    Available information suggests a mismatch between radiographic and orthopedic examination findings in cats with DJD. However, the extent of the discrepancy between clinical and radiographic signs of OA in companion animals has not been described in detail. This study aimed to evaluate the relationship between orthopedic examination findings, joint goniometry, and radiographic signs of DJD in 100 cats, in a prospective observational design. Cat temperament, pain response to palpation, joint crepitus, effusion and thickening were graded. Radiographs of appendicular joints and the axial skeleton were made under sedation. Joint motion was measured by use of a plastic goniometer before and after sedation. Associations between radiographic degenerative joint disease (DJD) and examination findings were assessed to determine sensitivity, specificity and likelihood estimations. Pain response to palpation was elicited in 0-67% of the joints with DJD, with a specificity ranging from 62-99%; crepitus was detected in 0-56% of the joints and its specificity varied between 87 and 99%; for effusion, values ranged between 6 and 38% (specificity, 82-100%), and thickening, 0-59% (specificity, 74-99%). Joints with DJD tended to have a decreased range of motion. The presence of pain increased the odds of having DJD in the elbow (right: 5.5; left: 4.5); the presence of pain in the lower back increased the odds of spinal DJD being present (2.97 for lumbar; 4.67 for lumbo-sacral). Radiographic DJD cannot be diagnosed with certainty using palpation or goniometry. However, negative findings tend to predict radiographically normal joints. Palpation and goniometry may be used as a tool to help to screen cats, mostly to rule out DJD.

  20. Relationship of orthopedic examination, goniometric measurements, and radiographic signs of degenerative joint disease in cats

    Directory of Open Access Journals (Sweden)

    Lascelles B Duncan X

    2012-01-01

    Full Text Available Abstract Background Available information suggests a mismatch between radiographic and orthopedic examination findings in cats with DJD. However, the extent of the discrepancy between clinical and radiographic signs of OA in companion animals has not been described in detail. This study aimed to evaluate the relationship between orthopedic examination findings, joint goniometry, and radiographic signs of DJD in 100 cats, in a prospective observational design. Cat temperament, pain response to palpation, joint crepitus, effusion and thickening were graded. Radiographs of appendicular joints and the axial skeleton were made under sedation. Joint motion was measured by use of a plastic goniometer before and after sedation. Associations between radiographic degenerative joint disease (DJD and examination findings were assessed to determine sensitivity, specificity and likelihood estimations. Results Pain response to palpation was elicited in 0-67% of the joints with DJD, with a specificity ranging from 62-99%; crepitus was detected in 0-56% of the joints and its specificity varied between 87 and 99%; for effusion, values ranged between 6 and 38% (specificity, 82-100%, and thickening, 0-59% (specificity, 74-99%. Joints with DJD tended to have a decreased range of motion. The presence of pain increased the odds of having DJD in the elbow (right: 5.5; left: 4.5; the presence of pain in the lower back increased the odds of spinal DJD being present (2.97 for lumbar; 4.67 for lumbo-sacral. Conclusions Radiographic DJD cannot be diagnosed with certainty using palpation or goniometry. However, negative findings tend to predict radiographically normal joints. Palpation and goniometry may be used as a tool to help to screen cats, mostly to rule out DJD.