WorldWideScience

Sample records for normal operation discharges

  1. The differential radiological impact of plutonium recycle in the light-water reactor fuel cycle: effluent discharges during normal operation

    International Nuclear Information System (INIS)

    Bouville, A.; Guetat, P.; Jones, J.A.; Kelly, G.N.; Legrand, J.; White, I.F.

    1980-01-01

    The radiological impact of a light-water reactor fuel cycle utilizing enriched uranium fuel may be altered by the recycle of plutonium. Differences in impact may arise during various operations in the fuel cycle: those which arise from effluents discharged during normal operation of the various installations comprising the fuel cycle are evaluated in this study. The differential radiological impact on the population of the European Communities (EC) of effluents discharged during the recycling of 10 tonnes of fissile plutonium metal is evaluated. The contributions from each stage of the fuel cycle, i.e. fuel fabrication, reactor operation and fuel reprocessing and conversion, are identified. Separate consideration is given to airborne and liquid effluents and account is taken of a wide range of environmental conditions, representative of the EC, in estimating the radiological impact. The recycle of plutonium is estimated to result in a reduction in the radiological impact from effluents of about 30% of that when using enriched uranium fuel

  2. The FOCON model to assess doses due to the atmospheric radioactive discharges of nuclear facilities during normal operation

    International Nuclear Information System (INIS)

    Rommens, C.; Morin, A.; Merle-Szeremeta, A.

    1999-01-01

    The FOCON model to assess doses due to the atmospheric radioactive discharges of nuclear facilities during normal operation. To assess the dosimetric impact to the public due to atmospheric radioactive discharges of nuclear facilities during normal operation, the Institute for Protection and Nuclear Safety has developed the FOCON96 code. FOCON96 calculates the dispersion of gases and aerosols into the environment (atmosphere contamination and ground deposition), their transfer in the biosphere (soils, plants and animals) and their impact to a member of the public (individual effective and equivalent doses, external exposure to the plume and to the deposits, internal exposure by inhalation and ingestion). FOCON96 uses ergonomic windows and proposes many capabilities (modular architecture, default values, choice of libraries, access to all the parameters of the models, listing or results, management of result files, calculations made directly, etc.). In the European context, and intercomparison with the PC-CREAM code, developed by the National Radiological Protection Board, has shown the coherence of the results of the two codes. A comparison of the windows and capabilities has shown that FOCON96 was easier to use. FOCON96 is not adapted to calculate the doses received during one particular year that are due to the discharges of a facility in operation for a long period of time. An evolution of the software will be considered if this kind of assessment is generalized. (authors)

  3. 75 FR 10477 - Draft Report to Congress: Study of Discharges Incidental to Normal Operation of Commercial...

    Science.gov (United States)

    2010-03-08

    ... evaluate the impacts of: (1) Any discharge of effluent from properly functioning marine engines; (2) Any... currently are regulated under the National Pollution Discharge Elimination System (NPDES) permitting program... included cable laying ships, cruise ships, large ferries, and oil and petroleum tankers. With the exception...

  4. Vaginal Discharge: What's Normal, What's Not

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Vaginal Discharge: What's Normal, What's Not KidsHealth / For Teens / Vaginal Discharge: What's Normal, What's Not Print Normal vaginal discharge ...

  5. Manual on environmental monitoring in normal operation

    International Nuclear Information System (INIS)

    1966-01-01

    Many establishments handling radioactive materials produce, and to some extent also discharge, radioactive waste as part of their normal operation. The radiation doses to which members of the public may be exposed during such operation must remain below the stipulated level. The purpose of this manual is to provide technical guidance for setting up programmes of routine environmental monitoring in the vicinity of nuclear establishment. The annex gives five examples of routine environmental monitoring programmes currently in use: these have been indexed separately.

  6. Lithium control during normal operation

    International Nuclear Information System (INIS)

    Suryanarayan, S.; Jain, D.

    2010-01-01

    Periodic increases in lithium (Li) concentrations in the primary heat transport (PHT) system during normal operation are a generic problem at CANDU® stations. Lithiated mixed bed ion exchange resins are used at stations for pH control in the PHT system. Typically tight chemistry controls including Li concentrations are maintained in the PHT water. The reason for the Li increases during normal operation at CANDU stations such as Pickering was not fully understood. In order to address this issue a two pronged approach was employed. Firstly, PNGS-A data and information from other available sources was reviewed in an effort to identify possible factors that may contribute to the observed Li variations. Secondly, experimental studies were carried out to assess the importance of these factors in order to establish reasons for Li increases during normal operation. Based on the results of these studies, plausible mechanisms/reasons for Li increases have been identified and recommendations made for proactive control of Li concentrations in the PHT system. (author)

  7. [Effectiveness of an early discharge program after normal childbirth].

    Science.gov (United States)

    Teulón González, M; Martínez Pillado, M; Cuadrado Martín, M M; Rivero Martín, M J; Cerezuela Requena, J F

    To implement a program of early hospital discharge after an uncomplicated birth, in order to improve the effectiveness, as well as ensuring clinical safety and patient acceptability. Descriptive study of the effectiveness of an early discharge program after uncomplicated delivery between February 2012 and September 2013. The populations are post-partum women and newborns admitted to the University Hospital of Fuenlabrada, with a duration of less than 24h after uncomplicated delivery that met the defined inclusion criteria. Satisfaction was assessed using a Likert scale. The effectiveness of the program was monitored by safety indicators, productivity, adaptation, and continuity of care. A total of 20% of cases capable of early discharge from Fuenlabrada University Hospital completed the program. Almost all (94%) were normal deliveries. The 188 cases included were from 911 patients with uncomplicated childbirth, accounting for 6.5% of the 2,857 total births. The mean stay of patients included showed a decrease of 50% (2.4 to 1.2 days). All patients received continuity of care after hospital discharge. The review consultation was reprogrammed for 4.8% of cases, with 2% of patients re-admitted within 96h. with no serious problems. Four newborns (2%) required attention in the emergency department (mother or newborn) before 96h. The assessment of patient satisfaction achieved a score of 4.5 out of 5. The program achieved a decrease in the average stay by 50%, favouring the autonomy of midwives. This acceptance level is in line with similar interventions. The deployment of the program may be useful for other changes in care processes. Copyright © 2016 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Perturbations of normally solvable nonlinear operators, I

    Directory of Open Access Journals (Sweden)

    William O. Ray

    1985-01-01

    Full Text Available Let X and Y be Banach spaces and let ℱ and be Gateaux differentiable mappings from X to Y In this note we study when the operator ℱ+ is surjective for sufficiently small perturbations of a surjective operator ℱ The methods extend previous results in the area of normal solvability for nonlinear operators.

  9. Generalized Hardy operators and normalizing measures

    OpenAIRE

    Chen Tieling; Sinnamon Gord

    2002-01-01

    Necessary and sufficient conditions on the weight and the measure for the operator to be bounded from to are given. Here and are similarly ordered functions and satisfies a modified GHO condition. Nearly block diagonal decompositions of positive operators are introduced as is the concept of a normalizing measure. An application is made to estimates for the remainder in a Taylor approximation.

  10. Operational behaviour of a reactor normal operation and disturbances

    International Nuclear Information System (INIS)

    Geyer, K.H.

    1982-01-01

    During normal operation, the following topics are dealt with: primary and secondary coolant circuits - full load operation - start-up and shutdown - steady state part load diagramm. During disturbances and incidents, the following procedures are discussed: identification and detection of the events - automatic actions - manual actions of the operator - provided indications - explanation of actuated systems - basic information of reactor protection system. (RW)

  11. Generalized Hardy operators and normalizing measures

    Directory of Open Access Journals (Sweden)

    Chen Tieling

    2002-01-01

    Full Text Available Necessary and sufficient conditions on the weight and the measure for the operator to be bounded from to are given. Here and are similarly ordered functions and satisfies a modified GHO condition. Nearly block diagonal decompositions of positive operators are introduced as is the concept of a normalizing measure. An application is made to estimates for the remainder in a Taylor approximation.

  12. Limiting Normal Operator in Quasiconvex Analysis

    Czech Academy of Sciences Publication Activity Database

    Aussel, D.; Pištěk, Miroslav

    2015-01-01

    Roč. 23, č. 4 (2015), s. 669-685 ISSN 1877-0533 R&D Projects: GA ČR GA15-00735S Institutional support: RVO:67985556 Keywords : Quasiconvex function * Sublevel set * Normal operator Subject RIV: BA - General Mathematics Impact factor: 0.973, year: 2015 http://library.utia.cas.cz/separaty/2015/MTR/pistek-0453552.pdf

  13. Operation of Ferroelectric Plasma Sources in a Gas Discharge Mode

    International Nuclear Information System (INIS)

    Dunaevsky, A.; Fisch, N.J.

    2004-01-01

    Ferroelectric plasma sources in vacuum are known as sources of ablative plasma, formed due to surface discharge. In this paper, observations of a gas discharge mode of operation of the ferroelectric plasma sources (FPS) are reported. The gas discharge appears at pressures between approximately 20 and approximately 80 Torr. At pressures of 1-20 Torr, there is a transition from vacuum surface discharge to the gas discharge, when both modes coexist and the surface discharges sustain the gas discharge. At pressures between 20 and 80 Torr, the surface discharges are suppressed, and FPS operate in pure gas discharge mode, with the formation of almost uniform plasma along the entire surface of the ceramics between strips. The density of the expanding plasma is estimated to be about 1013 cm-3 at a distance of 5.5 mm from the surface. The power consumption of the discharge is comparatively low, making it useful for various applications. This paper also presents direct measurements of the yield of secondary electron emission from ferroelectric ceramics, which, at low energies of primary electrons, is high and dependent on the polarization of the ferroelectric material

  14. Borel functional calculus for quaternionic normal operators

    Science.gov (United States)

    Ramesh, G.; Santhosh Kumar, P.

    2017-05-01

    In this article, we give an approach to Borel functional calculus for quaternionic normal operators, which are not necessarily bounded. First, we establish the definition of functional calculus for a subclass of quaternion valued Borel functions, and then we extend the same to the class of quaternion valued Borel functions as well as L∞-functions. We also prove spectral mapping theorem as a consequence.

  15. Crate counter for normal operating loss

    International Nuclear Information System (INIS)

    Harlan, R.A.

    A lithium-loaded zinc sulfide scintillation counter to closely assay plutonium in waste packaged in 1.3 by 1.3 by 2.13m crates was built. In addition to assays for normal operating loss accounting, the counter will allow safeguards verification immediately before shipment of the crates for burial. The counter should detect approximately 10 g of plutonium in 1000 kg of waste

  16. Overview Report: Normal and Emergency Operation Visualization

    Energy Technology Data Exchange (ETDEWEB)

    Greitzer, Frank L.

    2011-05-01

    This is an overview report to document and illustrate methods used in a project entitled “Normal and Emergency Operations Visualization” for a utility company, conducted in 2009-2010 timeframe with funding from the utility company and the U.S. Department of Energy. The original final report (about 180 pages) for the project is not available for distribution because it alludes to findings that assessed the design of an operational system that contained proprietary information; this abridged version contains descriptions of methods and some findings to illustrate the approach used, while avoiding discussion of sensitive or proprietary information. The client has approved this abridged version of the report for unlimited distribution to give researchers and collaborators the benefit of reviewing the research concepts and methods that were applied in this study.

  17. A bank-operated traveling-block cableway for stream discharge and sediment measurements

    Science.gov (United States)

    James J. Paradiso

    2000-01-01

    Streams often present a challenge for collecting flow and sediment measurements on a year-round basis. Streams that can normally be waded become hazardous during seasonal flows, either endangering hydrographers or precluding data collection completely. A hand-operated cableway permits the accurate and safe collection of discharge and sediment data from the stream bank...

  18. High performance discharges near the operational limit in HT-7

    International Nuclear Information System (INIS)

    Li Jiangang; Wan Baonian; Luo Jiarong; Gao Xiang; Zhao Yanping; Kuang Guangli; Zhang Xiaodong; Yang Yu; Yi Bao; Bojiang Ding; Jikang Xie; Yuanxi Wan

    2001-01-01

    Efforts have been made on the HT-7 tokamak to extend the stable operation boundaries. Extensive RF boronization and siliconization have been used and a wider operational Hugill diagram has been obtained. The transit density reached 1.3 times the Greenwald density limit in ohmic discharges. A stationary high performance discharge with q a =2.1 has been obtained after siliconization. Confinement improvement was obtained as a result of the significant reduction of electron thermal diffusivity χ e in the outer region of the plasma. An improved confinement phase was also observed with LHCD in the density range of 70-120% of the Greenwald density limit. Off-axis LH wave power deposition was attributed to the weak hollow current density profile. Code simulations and measurements showed good agreement with the off-axis LH wave deposition. Supersonic molecular beam injection has been successfully used to achieve stable high density operation in the region of the Greenwald density limit. (author)

  19. Performance of Models in Radiological Impact Assessment for Normal Operation. Report of Working Group 1 Reference Methodologies for Controlling Discharges of Routine Releases of EMRAS II Topical Heading Reference Approaches for Human Dose Assessment. Environmental Modelling for Radiation Safety (EMRAS II) Programme

    International Nuclear Information System (INIS)

    2017-01-01

    This publication provides the results from Working Group 1, on Reference Methodologies for Controlling Discharges of Routine Releases, of the IAEA’s EMRAS II (Environmental Modelling for Radiation Safety) programme, which ran from 2009 to 2011. This Working Group carried out an intercomparison of methods used for assessing radiological impacts to people and the environment due to authorized releases of radionuclides during normal operation of nuclear facilities. Three important types of exposure scenarios were considered, those related to atmospheric, marine and river releases. The publication describes the details of the hypothetical radioactive release scenarios, the environmental pathways considered, the environmental transfer models applied, the calculation methods and the results obtained. An analysis of the results and the main findings and conclusions relevant for the use of the described input data and methodologies in regulatory applications is included. The publication also presents considerations on selection of the ‘representative person’ and a summary of the different approaches in some States for the regulatory control of radioactive discharges. Input data is included in the annex.

  20. Is it safe to discharge blunt abdominal trauma patients with normal initial findings?

    Science.gov (United States)

    Chardoli, Mojtaba; Rezvani, Samina; Mansouri, Pejman; Naderi, Kaveh; Vafaei, Ali; Khorasanizadeh, MirHojjat; Rahimi-Movaghar, Vafa

    2017-08-01

    Trauma is the leading health concern among young adults. Blunt abdominal trauma (BAT) is the most common type of blunt traumas. BAT patients may prove normal in the initial clinical assessments, but since the time required for an intra-abdominal injury to be clinically apparent is not predictable, deciding when to safely discharge these patients could be a dilemma. The purpose of this study is to determine whether follow-up of the early discharged or further diagnostic assessment of the later discharged BAT patients with normal initial findings reveals any abnormal findings. Totally, 389 hemodynamically-stable patients suspected of BAT who arrived at the emergency department (ED) of two university hospitals in Tehran from September 2013 to September 2014 were included in this study. Upon arrival at the ED, all subjects underwent abdominal examination and FAST, and were assessed for hematocrit and base deficit levels and presence of hematuria. These assessments were repeated in the patients who were discharged after 6 h, at 6 or 12 h post-arrival. All patients were followed-up after 24 h and one week by phone call. Out of all study participants, 158 patients (40.6%) had normal findings in all initial assessments. These patients were discharged from the ED after a median of 5 h. After one week of follow-up, none of them had any symptom or complication, or had sought medical attention after being discharged from the study hospitals. Out of these patients, 78 patients (49.4%) were discharged after 6 hours by their physician's decision, and underwent the same diagnostic assessments for the second or third time. None of these assessments revealed any abnormal findings. A combination of normal abdominal exam, normal FAST, normal hematocrit, normal base deficit, and absence of hematuria rules out intra-abdominal injury in BAT patients. It is safe to discharge patients after they prove normal for these assessments. Longer observation and repeated diagnostic

  1. Berezin-Lieb Inequality: An Extension to Normal Operators | Sookia ...

    African Journals Online (AJOL)

    The Berezin-Lieb inequality, which is a Jensen's type inequality for convex functions of self-adjoint operators, is considered. We find a similar type of inequality for convex functions of normal operators. The normal operator is assumed to be bounded and acting on an infinite dimensional separable Hilbert space H. Finally ...

  2. Generalizing Refinement Operators to Learn Prenex Conjunctive Normal Forms

    NARCIS (Netherlands)

    S-H. Nienhuys-Cheng (Shan-Hwei); W. van Laer; J. Ramon; L. de Raedt

    2000-01-01

    textabstractInductive Logic Programming considers almost exclusively universally quantied theories. To add expressiveness, prenex conjunctive normal forms (PCNF) with existential variables should also be considered. ILP mostly uses learning with refinement operators. To extend refinement operators

  3. Flow protection trip limits operational charge-discharge facility -- C Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Van Wormer, F.W.

    1958-09-19

    Because of wide variations in the venturi throat pressure, well beyond the panellit gage trip range, that occur during the sequence of operational charge-discharge, the panellit gage cannot be included in the scram safety circuit during the period of time that charge- discharge operations are being performed. In its stead, the function of the panellit gage is replaced in an overlapping manner by a tube inlet pressure monitor that is equipped with high and low pressure trip mechanisms that may be included in the scram safety circuit during the time that the panellit gage must be by-passed. The tube inlet pressure monitor is then used to provide the protection from unstable flow that is normally obtained with the panellit gage. This memorandum describes the manner in which the tube inlet pressure monitor trip points are to be determined and used.

  4. Prognostic Significance of Discharge Hyponatremia in Heart Failure Patients With Normal Admission Sodium (from the ESCAPE Trial).

    Science.gov (United States)

    Omar, Hesham R; Charnigo, Richard; Guglin, Maya

    2017-08-15

    Hyponatremia in acute decompensated heart failure (HF) is indicative of a poor prognosis and predicts morbidity and mortality. We explored the predictive utility of hyponatremia at the time of hospital discharge among HF patients with normal admission sodium (Na). Characteristics and outcomes of HF patients enrolled in the Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness trial, who had normal Na on admission, were compared between those who were hyponatremic (Na normal admission Na had either hyponatremia (n = 86) or normal Na (n = 220) on discharge. Compared with patients with normal Na on discharge, hyponatremic patients were younger (p = 0.004), with lower discharge systolic (p normal Na on discharge regarding rehospitalization (p = 0.386), all-cause mortality (p = 0.440), and composite of death, cardiac rehospitalization, and cardiac transplant (p = 0.799), all up to 6-month following randomization. Restricted cubic spline analysis also showed no significant relationships between discharge Na and the aforementioned 3 outcomes. Cox proportional hazards regressions showed that discharge hyponatremia did not significantly predict any of the 3 outcomes after adjustment for imbalances at baseline. Among patients with discharge hyponatremia, a poor outcome was more likely if they were also hyponatremic on admission: the composite end point occurred in 69.2% of those also hyponatremic on admission versus 51.2% of those with normal Na on admission but decreased Na on discharge (p = 0.045). Because the median discharge Na level in the discharge hyponatremia group was 132 meq/L, our findings suggest a benign nature of mild discharge hyponatremia in HF patients with normal admission Na. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. AIR ATMOSPHERIC-PRESSURE DISCHARGERS FOR OPERATION IN HIGH-FREQUENCY SWITCHING MODE.

    Directory of Open Access Journals (Sweden)

    L.S. Yevdoshenko

    2013-10-01

    Full Text Available Operation of two designs of compact multigap dischargers has been investigated in a high-frequency switching mode. It is experimentally revealed that the rational length of single discharge gaps in the designs is 0.3 mm, and the maximum switching frequency is 27000 discharges per second under long-term stable operation of the dischargers. It is shown that in pulsed corona discharge reactors, the pulse front sharpening results in increasing the operating electric field strength by 1.3 – 1.8 times.

  6. New Perspectives on the Normal Vagina and Noninfectious Causes of Discharge.

    Science.gov (United States)

    Powell, Anna M; Nyirjesy, Paul

    2015-09-01

    An understanding of how the vaginal flora is influenced by hormonal status is crucial in distinguishing normal from abnormal secretions. New studies exploring the vaginal microbiome with culture-independent techniques have led to the discovery of previously uncultivable bacteria on a species level, and have contributed to a better understanding of disease processes including bacterial vaginosis. It is important to note that not all vaginal discharge is abnormal or infectious in etiology, but a thorough evaluation will help reassure both the patient and the provider.

  7. Stress sources during normal operation of a nuclear power plant

    International Nuclear Information System (INIS)

    Saint Jean, T.

    1986-03-01

    This study points out some concrete aspects of the reality of working conditions during normal operation of a nuclear power plant which create incertitudes in the working situation of operators. Some of these incertitudes are inevitable and are induced by the life of any complex organization, but others are at the origin of a potential stress: incertitudes related to work organization and, incertitudes related to the operation of installations. These results lead to choose actions to prevent these stress situation rather than to correct the operator [fr

  8. Normally ordered expansion of 3-dimensional bipartite Coulomb potential operator

    Energy Technology Data Exchange (ETDEWEB)

    Fan Hongyi [CCAST (World Laboratory), P.O. Box 8730, Beijing 100080 (China) and Department of Physics, Shanghai Jiao Tong University, Shanghai 200030 (China) and Department of Material Science and Engineering, University of Science and Technology of China, Hefei, Anhui 230026 (China)]. E-mail: fhym@ustc.edu.cn; Fu Liang [Special Class for the Gifted Young, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2004-08-23

    We derive the normally ordered expansion formula of bipartite Coulomb potential operator vertical bar R->{alpha}-R->{beta} vertical bar -1 by virtue of the method of integral within an ordered product of operators and the entangled state representation, where vertical bar R->{alpha}-R->{beta} vertical bar is the distance between two particles' positions. The new expansion formula provides convenience for calculating its coherent states' matrix elements. The normally ordered expansion of vertical bar R->{alpha}-R->{beta} vertical bar k, k>=-2, is also deduced.

  9. Calculations of stresses in GCFR cladding under normal operating conditions

    International Nuclear Information System (INIS)

    Liu, Y.Y.; Hsieh, T.C.; Billone, M.C.

    1979-11-01

    A modified version of the LIFE-III code, LIFE-GCFR, and classical stress-analysis techniques have been used to calculate the stresses in the GCFR cladding under normal reactor operating conditions. Several types of loadings on the cladding that occur during normal operation have been considered. These include fuel-cladding mechanical interaction, thermal stresses induced by radial and axial temperature gradients, and swelling gradient-induced stresses. The combined and individual effects of these loadings, as well as the effect of creep on cladding stresses, have been assessed

  10. Systematic investigation of the barrier discharge operation in helium, nitrogen, and mixtures: discharge development, formation and decay of surface charges

    Science.gov (United States)

    Tschiersch, R.; Bogaczyk, M.; Wagner, H.-E.

    2014-09-01

    As a logical extension to previous investigations of the barrier discharge (BD) in helium and nitrogen, the present work reports on the operation in any mixtures of both pure gases. Using a well-established plane-parallel discharge cell configuration allows to study the influence of the He/N2 mixing ratio on the formation of different discharge modes. Their characterization was made by measuring the discharge emission development together with the formation and decay of surface charges on a bismuth silicon oxide (Bi12SiO20, BSO) crystal. This was realized by the simultaneous application of the spatio-temporally resolved optical emission spectroscopy, and the electro-optic Pockels effect in combination with a CCD high speed camera. The existence diagram for diffuse and filamentary BDs was determined by varying the amplitude and shape of the applied voltage. Over the entire range of the He/N2 ratio, the diffuse mode can be operated at moderate voltage amplitudes whereas filamentation occurs at significant overvoltage and is favoured by a high voltage slew rate. Irrespective of the discharge mode, the overall charge transfer during a discharge breakdown is found to be in excellent agreement with the amount of accumulated surface charges. An exponential decay of the surface charge deposited on the BSO crystal is induced by LED illumination beyond a typical discharge cycle. During the decay process, a broadening of the radial profiles of positive as well as negative surface charge spots originating from previous microdischarges is observed. The investigations contribute to a better understanding of the charge accumulation at a dielectric.

  11. Fabricating TiO2 nanocolloids by electric spark discharge method at normal temperature and pressure

    Science.gov (United States)

    Tseng, Kuo-Hsiung; Chang, Chaur-Yang; Chung, Meng-Yun; Cheng, Ting-Shou

    2017-11-01

    In this study, TiO2 nanocolloids were successfully fabricated in deionized water without using suspending agents through using the electric spark discharge method at room temperature and under normal atmospheric pressure. This method was exceptional because it did not create nanoparticle dispersion and the produced colloids contained no derivatives. The proposed method requires only traditional electrical discharge machines (EDMs), self-made magnetic stirrers, and Ti wires (purity, 99.99%). The EDM pulse on time (T on) and pulse off time (T off) were respectively set at 50 and 100 μs, 100 and 100 μs, 150 and 100 μs, and 200 and 100 μs to produce four types of TiO2 nanocolloids. Zetasizer analysis of the nanocolloids showed that a decrease in T on increased the suspension stability, but there were no significant correlations between T on and particle size. Colloids produced from the four production configurations showed a minimum particle size between 29.39 and 52.85 nm and a zeta-potential between -51.2 and -46.8 mV, confirming that the method introduced in this study can be used to produce TiO2 nanocolloids with excellent suspension stability. Scanning electron microscopy with energy dispersive spectroscopy also indicated that the TiO2 colloids did not contain elements other than Ti and oxygen.

  12. Potential Industrial Applications of the One Atmosphere Uniform Glow Discharge Plasma (OAUGDP) Operating in Ambient Air

    Science.gov (United States)

    Reece Roth, J.

    2004-11-01

    The majority of industrial plasma processing with glow discharges has been conducted at pressures below 10 torr. This tends to limit applications to high value workpieces as a result of the high capital cost of vacuum systems and the production constraints of batch processing. It has long been recognized that glow discharge plasmas would play a much larger industrial role if they could be generated at one atmosphere. The One Atmosphere Uniform Glow Discharge Plasma (OAUGDP), developed at the University of Tennessee's Plasma Sciences Laboratory, is a non-thermal RF plasma operating on displacement currents with the time-resolved characteristics of a classical low pressure DC normal glow discharge. As a glow discharge, the OAUGDP operates with maximum electrical efficiency at the Stoletow point, where the energy input per ion-electron pair is a minimum [1, 2]. Several interdisciplinary teams have investigated potential applications of the OAUGDP. These teams included collaborators from the UTK Textiles and Nonwovens Development Center (TANDEC), and the Departments of Electrical and Computer Engineering, Microbiology, and Food Science and Technology, as well as the NASA Langley Research Center. The potential applications of the OAUGDP have all been at one atmosphere and room temperature, using air as the working gas. These applications include sterilizing medical and dental equipment; sterilizable air filters to deal with the "sick building syndrome"; removal of soot from Diesel engine exhaust; subsonic plasma aerodynamic effects, including flow re-attachment to airfoils and boundary layer modification; electrohydrodynamic (EDH) flow control of working gases; increasing the surface energy of materials; improving the adhesion of paints and electroplated layers: improving the wettability and wickability of fabrics; stripping of photoresist; and plasma deposition and directional etching of potential microelectronic relevance. [1] J. R. Roth, Industrial Plasma Engineering

  13. Peak discharge estimates of glacial-lake outburst floods and ``normal'' climatic floods in the Mount Everest region, Nepal

    Science.gov (United States)

    Cenderelli, Daniel A.; Wohl, Ellen E.

    2001-09-01

    Glacial-lake outburst floods (GLOFs) in the Mount Everest region of Nepal on 3 September 1977 and 4 August 1985 dramatically modified channels and valleys in the region by eroding, transporting, and depositing large quantities of sediment for tens of kilometers along their flood routes. Prior to this research, the GLOF discharges had not been determined and the hydrology of "normal" climatic floods (SHFFs: seasonal high flow floods) was not known. A one-dimensional step-backwater flow model was utilized, in conjunction with paleostage indicators, to estimate the peak discharges of the GLOFs and SHFFs and to reconstruct the hydrology and hydraulic conditions of the GLOFs at 10 reaches and SHFFs at 18 reaches. The most reliable GLOF and SHFF peak discharge estimates were upstream from constrictions where there was critical-depth control. The peak discharge of the 1977 GLOF at 8.6 km from the breached moraine was approximately 1900 m 3/s. At 7.1 km downstream from the breached moraine, the 1985 GLOF discharge was estimated at 2350 m 3/s. At 27 km downstream from the breached moraine, the 1985 GLOF attenuated to an estimated discharge of 1375 m 3/s. The peak discharges of SHFFs ranged from 7 to 205 m 3/s and were positively correlated with increasing drainage area. The GLOF discharges were 7 to 60 times greater than the SHFF discharges with the greatest ratios occurring near the breached moraines. The downstream decline in the ratio between the GLOF discharge and SHFF discharge is the result of the downstream attenuation of the GLOF and the increased discharge of the SHFF because of increased contributing drainage area and the increased effects of monsoonal precipitation at lower elevations.

  14. Environmental dosimetry for normal operations at SRP. Revision 1

    International Nuclear Information System (INIS)

    Marter, W.L.

    1984-01-01

    The radiological effect of environmental releases from SRP during normal operations has been assessed annually since 1972 with a dosimetry model developed by SRL in 1971 to 1972, as implemented in the MREM code for atmospheric releases and RIVDOSE code for liquid releases. Starting in 1978, SRL started using environmental models and dose commitment factors developed by Nuclear Regulatory Commission (NRC) for all other environmental dose calculations. The NRC models are more flexible than the older SRL models, use more up-to-date methodologies, cover more exposure pathways, and permit more detailed analysis of effects of normal operations. It is recommended that the NRC models, as implemented in the computer codes X0QD0Q and GASPAR for atmospheric releases and LADTAP for liquid releases, and NRC dose commitment factors be used as the standard method at SRP for assessing offsite dose from normal operations in Health Protection Department annual environmental monitoring reports, and in National Environmental Policy Act documents and Safety Analysis Reports for SRP facilities. 23 references, 3 figures, 9 tables

  15. 33 CFR 151.79 - Operating requirements: Discharge of sewage within Antarctica.

    Science.gov (United States)

    2010-07-01

    ... of sewage within Antarctica. 151.79 Section 151.79 Navigation and Navigable Waters COAST GUARD... Pollution and Sewage § 151.79 Operating requirements: Discharge of sewage within Antarctica. (a) A vessel certified to carry more than 10 persons must not discharge untreated sewage into the sea within 12 nautical...

  16. Normally ordered expansion of the inverse of the coordinate operator and the momentum operator

    Energy Technology Data Exchange (ETDEWEB)

    Fan Hongyi [CCAST (World Laboratory), PO Box 8730, Beijing 100080 (China); Fu Liang [Special Class for the Gifted Young, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2003-05-09

    We derive the normally ordered expansion formulae of 1/X-hat{sup n} and 1/P-hat{sup n} by virtue of the method of integral within an ordered product of operators in the sense of the principal value integral, where X-hat, P-hat are the coordinate and momentum operator, respectively. Application of the new formula is briefly discussed.

  17. Regulating manure application discharges from concentrated animal feeding operations in the United States

    International Nuclear Information System (INIS)

    Centner, Terence J.; Feitshans, Theodore A.

    2006-01-01

    In the United States, reducing pollution from agriculture has received attention due to data suggesting that this is the leading source of impairment of many waterbodies. The federal government revised its regulations governing concentrated animal feeding operations (CAFOs) to enhance governmental oversight over sources of pollution. For the application of manure resulting in pollutant discharges, CAFOs need to implement nutrient management plans. A federal court affirmed the ability of the US federal government to oversee the application of manure from CAFOs that have discharges. Simultaneously, owners and operators of CAFOs who have implemented an appropriate nutrient management plan may forgo securing a permit if their discharges qualify under the agricultural stormwater discharge exemption. - New rules applying to the application of manure by large concentrated animal feeding operations should reduce water contamination

  18. Dioxins from medical waste incineration: Normal operation and transient conditions.

    Science.gov (United States)

    Chen, Tong; Zhan, Ming-xiu; Yan, Mi; Fu, Jian-ying; Lu, Sheng-yong; Li, Xiao-dong; Yan, Jian-hua; Buekens, Alfons

    2015-07-01

    Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are key pollutants in waste incineration. At present, incinerator managers and official supervisors focus only on emissions evolving during steady-state operation. Yet, these emissions may considerably be raised during periods of poor combustion, plant shutdown, and especially when starting-up from cold. Until now there were no data on transient emissions from medical (or hospital) waste incineration (MWI). However, MWI is reputed to engender higher emissions than those from municipal solid waste incineration (MSWI). The emission levels in this study recorded for shutdown and start-up, however, were significantly higher: 483 ± 184 ng Nm(-3) (1.47 ± 0.17 ng I-TEQ Nm(-3)) for shutdown and 735 ng Nm(-3) (7.73 ng I-TEQ Nm(-3)) for start-up conditions, respectively. Thus, the average (I-TEQ) concentration during shutdown is 2.6 (3.8) times higher than the average concentration during normal operation, and the average (I-TEQ) concentration during start-up is 4.0 (almost 20) times higher. So monitoring should cover the entire incineration cycle, including start-up, operation and shutdown, rather than optimised operation only. This suggestion is important for medical waste incinerators, as these facilities frequently start up and shut down, because of their small size, or of lacking waste supply. Forthcoming operation should shift towards much longer operating cycles, i.e., a single weekly start-up and shutdown. © The Author(s) 2015.

  19. Process evaluation of discharge planning implementation in healthcare using normalization process theory

    OpenAIRE

    Nordmark, Sofi; Zingmark, Karin; Lindberg, Inger

    2016-01-01

    Background Discharge planning is a care process that aims to secure the transfer of care for the patient at transition from home to the hospital and back home. Information exchange and collaboration between care providers are essential, but deficits are common. A wide range of initiatives to improve the discharge planning process have been developed and implemented for the past three decades. However, there are still high rates of reported medical errors and adverse events related to failures...

  20. Effect of the field dependence of the coefficient of ion-electron emission on the characteristics of a normal cathode discharge

    NARCIS (Netherlands)

    Azarov, AV; Ochkin, VN

    2004-01-01

    The electric characteristics of the cathode layer of a normal glow discharge are discussed. The value of the normal current density and its dependence on the discharge parameters are modeled within a one-dimensional drift approximation with a local ionization. The dependence of the coefficient of

  1. Impact of oil on the marine environment: policy of the Paris Commission on operational discharges from the offshore industry

    International Nuclear Information System (INIS)

    Nihoul, C.; Ducrotoy, J.-P.

    1994-01-01

    The input of oil to the North Sea due to the offshore industry has been estimated at 29% of the total input of oil. The operational discharges consist of production water and drilling cuttings. An overview of statistics collected over the last 10 years shows that although the amount of oil discharged via production water is increasing as platforms are getting older, cuttings still account for 75% of the oil entering the sea as a result of normal operations. Spills represent a relatively small source of oil. The effects on the marine environment of discharges of production water and of discarded oily cuttings have been extensively studied, by national authorities as well as by the industry. Although it has not always been possible to reach consensus about the significance of the observed effects, a number of 'agreed facts' have led to the establishment of regulations in the framework of the Paris Commission. The 'decisions' and 'recommendations' adopted by the Commission are regularly reviewed in the light of new developments. (author)

  2. Radioactivity in gaseous waste discharged from the separations facilities during 1978. [Rockwell Hanford Operations

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, J. D.; Poremba, B. E.

    1979-03-30

    This document is issued quarterly for the purpose of summarizing the radioactive gaseous wastes that are discharged from the facilities of the Rockwell Hanford Operations. Data on alpha and beta emissions during 1978 are presented where relevant to the gaseous effluent. Emission data are not included on gaseous wastes produced within the 200 Areas by other Hanford contractors.

  3. Cathode fall parameters of a self-sustained normal glow discharge in atmospheric-pressure helium

    International Nuclear Information System (INIS)

    Arkhipenko, V.I.; Zgirovskii, S.M.; Kirillov, A.A.; Simonchik, L.V.

    2002-01-01

    Results from comprehensive studies of a high-current self-sustained glow discharge in atmospheric-pressure helium are presented. The main parameters of the cathode fall, namely, the electric field profile, cathode fall thickness, current density, gas temperature, and heat flux to the cathode are determined. The results obtained are discussed using one-dimensional models of the cathode fall with allowance for volumetric heat release

  4. EMERALD-NORMAL, Routine Radiation Release and Dose for PWR Design Analysis and Operation Analysis

    International Nuclear Information System (INIS)

    Gillespie, S.G.; Brunot, W.K.

    1976-01-01

    1 - Description of problem or function: EMERALD-NORMAL is designed for the calculation of radiation releases and exposures resulting from normal operation of a large pressurized water reactor. The approach used is similar to an analog simulation of a real system. Each component or volume in the plant which contains a radioactive material is represented by a subroutine which keeps track of the production, transfer, decay, and absorption of radioactivity in that volume. During the course of the analysis, activity is transferred from subroutine to subroutine in the program as it would be transferred from place to place in the plant. Some of this activity is then released to the atmosphere and to the discharge canal. The rates of transfer, leakage, production, cleanup, decay, and release are read as input to the program. Subroutines are also included which calculate the off-site radiation exposures at various distances for individual isotopes and sums of isotopes. The program contains a library of physical data for the forty isotopes of most interest in licensing calculations, and other isotopes can be added or substituted. Because of the flexible nature of the simulation approach, the EMERALD-NORMAL program can be used for most calculations involving the production and release of radioactive material. These include design, operation, and licensing studies. 2 - Method of solution: Explicit solutions of first-order linear differential equations are included. In addition, a subroutine is provided which solves a set of simultaneous linear algebraic equations. 3 - Restrictions on the complexity of the problem: Many parameters and systems included in the program, particularly the radiation waste-treatment system, are unique to the PG and E Diablo Canyon PWR plant. Maxima of: 50 isotopes, 9 distances, 16 angular sectors, 1 operating period, 1 reactor power level

  5. Operational control of material release and discharges from nuclear power plant

    International Nuclear Information System (INIS)

    Szabo, I. C.; Ranga, T.; Daroczi, L.; Deme, S.; Kerekes, A.

    2003-01-01

    The operational control of radioactive materials during atmospheric release and aquatic discharge from nuclear power plant is a licensing criterion for NPPs. Originally at the Paks NPP the release control was based on activity limits for four groups of elements. These groups were noble gases, long living radio-aerosols, radioiodine and radiostrontium for atmospheric release and specified activity limit for beta emitters, strontium and tritium for aquatic discharge into Danube. These groups were controlled with proper sampling and/or measuring instrumentation. The limit for atmospheric release was given as a 30-day moving average, for liquid discharges the annual limit was stipulated. The new release and discharge limitation system is based on the environmental dose limitation. The dose constraint for Paks NPP is 90 Sv/year of the critical group for all release pathways and the investigation dose limit is equal to 27 Sv/year. The regulation did not subdivide the dose limit for atmospheric and liquid components but for operational control subdivision of dose limits for atmospheric release and aquatic discharge and shorter time period (one day-one month) seems to be useful. The subdivision can be based on past release data and/or previous activity limits. To satisfy dose below the investigation dose limit there should be a proper operation control level for each separately measured component and pathway belonging to reasonable time interval significantly shorter than one year. The main task of the NPP staff is elaboration of reasonable control levels and reference time intervals for different radionuclide and element groups to be used in operational control. Operational control levels are based on measured daily or monthly release rates. In case of noble gases, aerosols and iodine the daily release rates have several sharp peaks per year. Operational control levels give opportunity to detect these peaks for internal investigation purposes. Investigation release limits

  6. Reliability analysis of meteorological data registered during nuclear power plant normal operation

    International Nuclear Information System (INIS)

    Amado, V.; Ulke, A.; Marino, B.; Thomas, L.

    2011-01-01

    The atmosphere is the environment in which gaseous radioactive discharges from nuclear power plants are transported. It is therefore essential to have reliable meteorological information to characterize the dispersion and feed evaluation models and radiological environmental impact during normal operation of the plant as well as accidental releases. In this way it is possible to determine the effects on the environment and in humans. The basic data needed to represent adequately the local weather include air temperature, wind speed and direction, rainfall, humidity and pressure. On the other hand, specific data consistent with the used model is required to determine the turbulence, for instance, radiation, cloud cover and vertical temperature gradient. It is important that the recorded data are representative of the local meteorology. This requires, first, properly placed instruments, that should be kept in operation and undergoing maintenance on a regular basis. Second, but equally substantial, a thorough analysis of its reliability must be performed prior to storage and/or data processing. In this paper we present the main criteria to consider choosing the location of a meteorological tower in the area of a nuclear power plant and propose a methodology for assessing the reliability of recorded data. The methodology was developed from the analysis of meteorological data registered in nuclear power plants in Argentina. (authors) [es

  7. Initial operation of the CW 8X H- ion source discharge

    International Nuclear Information System (INIS)

    Smith, H.V. Jr.; Allison, P.; Geisik, C.; Schmitt, D.R.; Schneider, J.D.; Stelzer, J.E.

    1993-01-01

    A pulsed 8Χ source was built and the H - beam current, emittance, and power efficiency were measured. These results were promising, so a cooled, dc version designed for operation at arc power levels up to 30 kW was built. Testing of the CW 8Χ source discharge is underway. The design dc power loading on the cathode surface is 900 W/cm 2 , considerably higher than achieved in any pervious Penning surface-plasma source (SPS). Thus, the electrode surfaces are cooled with pressurized, hot water. We describe the source and present the initial operating experience and arc test results

  8. On an inequality for non-normal operators

    International Nuclear Information System (INIS)

    Duggal, B.P.

    1992-07-01

    Starting from the inequality proved by Takayuki Furuta for a dominant operator A on a complex Hilbert space H, which extends to all operators such that the pure part of A has empty point spectrum, it is shown that if A is a contraction (on a separable complex Hilbert space) with simple eigenvalues and C 0 completely non-unitary part, and if (1-A*A) 1/2 is of Hilbert-Schmidt class, then the said inequality holds for A. 8 refs

  9. Environmental and economic assessment of discharges from Gulf of Mexico region oil and gas operations

    International Nuclear Information System (INIS)

    Gettleson, D.A.

    1993-01-01

    Continental Shelf Associates, Inc. (CSA) was contracted to conduct a three-year study of the environmental and health related impacts of produced water and sand discharges from oil and gas operations. Data on naturally occurring radioactive materials (NORM), heavy metals, and hydrocarbons in water, sediment, and biota will be collected and evaluated. Health related impacts will be studied through field collections and analyses of commercially- and recreationally-important fish and shellfish tissues. Additionally, information on seafood catch, consumption, and use patterns for the Gulf of Mexico will be gathered and analyzed. The facilities to be studied will include both offshore and coastal facilities in the Gulf of Mexico. Coastal sites will be additionally studied to determine ecological recovery of impacted wetland and open bay areas. The economic impact of existing and proposed effluent federal and state regulations will also be evaluated. The primary objectives of the project are to increase the base of scientific knowledge concerning (1) the fate and environmental effects of organics, trace metals, and NORM in water, sediment, and biota near several offshore oil and gas facilities; (2) the characteristics of produced water and produced sand discharges as they pertain to organics, trace metals, and NORM variably found in association with the discharges; (3) the recovery of four terminated produced water discharge sites located in wetland and high-energy open bay sites of coastal Louisiana and Texas; (4) the economic and energy supply impacts of existing and anticipated federal and state offshore and coastal discharge regulations; and (5) the catch, consumption and human use patterns of seafood species collected from coastal and offshore waters. Accomplishments for this period are described

  10. New application of procedures computer to normal operating procedures

    Energy Technology Data Exchange (ETDEWEB)

    Medrano Carbajo, J.; Mendez Salguero, J.

    2012-07-01

    Currently, existing technologies in the operating power plants accused increasingly more problems of obsolescence and replacement of equipment supply. For this reason are spreading, to a greater or lesser extent, the projects of migration from analogue to digital technology systems. These systems, in line with the current situation of the industry, provide solutions to such problems and other advantages.

  11. Safety operation of chromatography column system with discharging hydrogen radiolytically generated

    Directory of Open Access Journals (Sweden)

    Watanabe Sou

    2015-01-01

    Full Text Available In the extraction chromatography system, accumulation of hydrogen gas in the chromatography column is suspected to lead to fire or explosion. In order to prevent the hazardous accidents, it is necessary to evaluate behaviors of gas radiolytically generated inside the column. In this study, behaviors of gas inside the extraction chromatography column were investigated through experiments and Computation Fluid Dynamics (CFD simulation. N2 gas once accumulated as bubbles in the packed bed was hardly discharged by the flow of mobile phase. However, the CFD simulation and X-ray imaging on γ-ray irradiated column revealed that during operation the hydrogen gas generated in the column was dissolved into the mobile phase without accumulation and discharged.

  12. Plasma dynamics in a packed bed dielectric barrier discharge (DBD) operated in helium

    Science.gov (United States)

    Mujahid, Zaka-ul-Islam; Hala, Ahmed

    2018-03-01

    Packed bed dielectric barrier discharges (DBDs) are very promising for several applications including remediation of environmental pollutants and greenhouse gas conversion. In this work, we have investigated the space and time-resolved emission from a packed bed DBD operated in helium, to understand the plasma dynamics. We have chosen a simple planar DBD arrangement with a patterned dielectric, which mimics the spherical boundaries between the dielectric pellets and allows the optical access to the plasma. The results show that plasma is sustained in a packed bed DBD by three mechanisms: filamentary discharge in the void (between the center of dielectric structures and the opposite electrode), microdischarges at the contact points and surface ionization waves over the dielectric surface. It is observed that for most of the duration plasma is generated at the contact points between the dielectric structures.

  13. Operation of an Extremely Compact Capillary Discharge Soft X-Ray Laser

    Science.gov (United States)

    Benware, B. R.; Moreno, C. H.; Burd, D. J.; Rocca, J. J.

    1996-11-01

    A major goal in ultrashort wavelength laser research is the development of practical laser sources that can impact applications. Of particular interest is the development of compact "table-top" amplifiers. We have previously reported the first observation of large soft x-ray amplification, at 46.9 nm in the J=0-1 line of Ne-like argon in a plasma column generated by a fast capillary discharge.(J. J. Rocca, V. Shlyaptsev, F. G. Tomasel, O. D. Cortazar, D. Hartshorn, and J. L. A. Chilla, Phys. Rev. Lett. 73), 2192 (1994). Herein we report the successful operation of an extremely compact table-top discharge driven 46.9 nm laser. Measurement of the soft x-ray laser output pulse energy, pulse duration and beam divergence will be reported. Work supported by the National Science Foundation.

  14. Normalization.

    Science.gov (United States)

    Cuevas, Eduardo J.

    1997-01-01

    Discusses cornerstone of Montessori theory, normalization, which asserts that if a child is placed in an optimum prepared environment where inner impulses match external opportunities, the undeviated self emerges, a being totally in harmony with its surroundings. Makes distinctions regarding normalization, normalized, and normality, indicating how…

  15. Direct current microhollow cathode discharges on silicon devices operating in argon and helium

    Science.gov (United States)

    Michaud, R.; Felix, V.; Stolz, A.; Aubry, O.; Lefaucheux, P.; Dzikowski, S.; Schulz-von der Gathen, V.; Overzet, L. J.; Dussart, R.

    2018-02-01

    Microhollow cathode discharges have been produced on silicon platforms using processes usually used for MEMS fabrication. Microreactors consist of 100 or 150 μm-diameter cavities made from Ni and SiO2 film layers deposited on a silicon substrate. They were studied in the direct current operating mode in two different geometries: planar and cavity configuration. Currents in the order of 1 mA could be injected in microdischarges operating in different gases such as argon and helium at a working pressure between 130 and 1000 mbar. When silicon was used as a cathode, the microdischarge operation was very unstable in both geometry configurations. Strong current spikes were produced and the microreactor lifetime was quite short. We evidenced the fast formation of blisters at the silicon surface which are responsible for the production of these high current pulses. EDX analysis showed that these blisters are filled with argon and indicate that an implantation mechanism is at the origin of this surface modification. Reversing the polarity of the microdischarge makes the discharge operate stably without current spikes, but the discharge appearance is quite different from the one obtained in direct polarity with the silicon cathode. By coating the silicon cathode with a 500 nm-thick nickel layer, the microdischarge becomes very stable with a much longer lifetime. No current spikes are observed and the cathode surface remains quite smooth compared to the one obtained without coating. Finally, arrays of 76 and 576 microdischarges were successfully ignited and studied in argon. At a working pressure of 130 mbar, all microdischarges are simultaneously ignited whereas they ignite one by one at higher pressure.

  16. Future changes in Mekong River hydrology: impact of climate change and reservoir operation on discharge

    Science.gov (United States)

    Lauri, H.; de Moel, H.; Ward, P. J.; Räsänen, T. A.; Keskinen, M.; Kummu, M.

    2012-12-01

    The transboundary Mekong River is facing two ongoing changes that are expected to significantly impact its hydrology and the characteristics of its exceptional flood pulse. The rapid economic development of the riparian countries has led to massive plans for hydropower construction, and projected climate change is expected to alter the monsoon patterns and increase temperature in the basin. The aim of this study is to assess the cumulative impact of these factors on the hydrology of the Mekong within next 20-30 yr. We downscaled the output of five general circulation models (GCMs) that were found to perform well in the Mekong region. For the simulation of reservoir operation, we used an optimisation approach to estimate the operation of multiple reservoirs, including both existing and planned hydropower reservoirs. For the hydrological assessment, we used a distributed hydrological model, VMod, with a grid resolution of 5 km × 5 km. In terms of climate change's impact on hydrology, we found a high variation in the discharge results depending on which of the GCMs is used as input. The simulated change in discharge at Kratie (Cambodia) between the baseline (1982-1992) and projected time period (2032-2042) ranges from -11% to +15% for the wet season and -10% to +13% for the dry season. Our analysis also shows that the changes in discharge due to planned reservoir operations are clearly larger than those simulated due to climate change: 25-160% higher dry season flows and 5-24% lower flood peaks in Kratie. The projected cumulative impacts follow rather closely the reservoir operation impacts, with an envelope around them induced by the different GCMs. Our results thus indicate that within the coming 20-30 yr, the operation of planned hydropower reservoirs is likely to have a larger impact on the Mekong hydrograph than the impacts of climate change, particularly during the dry season. On the other hand, climate change will increase the uncertainty of the

  17. Future changes in Mekong River hydrology: impact of climate change and reservoir operation on discharge

    Directory of Open Access Journals (Sweden)

    H. Lauri

    2012-12-01

    Full Text Available The transboundary Mekong River is facing two ongoing changes that are expected to significantly impact its hydrology and the characteristics of its exceptional flood pulse. The rapid economic development of the riparian countries has led to massive plans for hydropower construction, and projected climate change is expected to alter the monsoon patterns and increase temperature in the basin. The aim of this study is to assess the cumulative impact of these factors on the hydrology of the Mekong within next 20–30 yr. We downscaled the output of five general circulation models (GCMs that were found to perform well in the Mekong region. For the simulation of reservoir operation, we used an optimisation approach to estimate the operation of multiple reservoirs, including both existing and planned hydropower reservoirs. For the hydrological assessment, we used a distributed hydrological model, VMod, with a grid resolution of 5 km × 5 km. In terms of climate change's impact on hydrology, we found a high variation in the discharge results depending on which of the GCMs is used as input. The simulated change in discharge at Kratie (Cambodia between the baseline (1982–1992 and projected time period (2032–2042 ranges from −11% to +15% for the wet season and −10% to +13% for the dry season. Our analysis also shows that the changes in discharge due to planned reservoir operations are clearly larger than those simulated due to climate change: 25–160% higher dry season flows and 5–24% lower flood peaks in Kratie. The projected cumulative impacts follow rather closely the reservoir operation impacts, with an envelope around them induced by the different GCMs. Our results thus indicate that within the coming 20–30 yr, the operation of planned hydropower reservoirs is likely to have a larger impact on the Mekong hydrograph than the impacts of climate change, particularly during the dry season. On the other hand, climate change will

  18. Operational river discharge forecasting in poorly gauged basins: the Kavango River basin case study

    DEFF Research Database (Denmark)

    Bauer-Gottwein, Peter; Jensen, Iris Hedegaard; Guzinski, R.

    2015-01-01

    assimilation techniques. However, few studies have attempted to develop operational probabilistic forecasting approaches for large and poorly gauged river basins. The objective of this study is to develop open-source software tools to support hydrologic forecasting and integrated water resources management......Operational probabilistic forecasts of river discharge are essential for effective water resources management. Many studies have addressed this topic using different approaches ranging from purely statistical black-box approaches to physically based and distributed modeling schemes employing data...... in Africa. We present an operational probabilistic forecasting approach which uses public-domain climate forcing data and a hydrologic-hydrodynamic model which is entirely based on open-source software. Data assimilation techniques are used to inform the forecasts with the latest available observations...

  19. Metals analysis for emission spectroscopic in the incandescent discharge operated with continuous flow of He to atmospheric pressure

    International Nuclear Information System (INIS)

    Alzate Londono, Hugo

    1990-01-01

    By means of a small power source a glow discharge in generated with he flowing at atmospheric pressure. Into a device situated to some distance from the discharge an aqueous sample of a metallic ion is injected. The device is then gradually moved to the discharge for producing solvent vaporization, charring, atomization, excitation and finally atomic emission of the sample. By emission spectrophotometer the following elements were analyzed: Ag, Cd, Cr, Cu, Hg, K, Na, Pb and Zn. For every one the useful range and the detection limit were established after founding the best operation conditions for the discharge

  20. Integral type operators from normal weighted Bloch spaces to QT,S spaces

    Directory of Open Access Journals (Sweden)

    Yongyi GU

    2016-08-01

    Full Text Available Operator theory is an important research content of the analytic function space theory. The discussion of simultaneous operator and function space is an effective way to study operator and function space. Assuming that  is an analytic self map on the unit disk Δ, and the normal weighted bloch space μ-B is a Banach space on the unit disk Δ, defining a composition operator C∶C(f=f on μ-B for all f∈μ-B, integral type operator JhC and CJh are generalized by integral operator and composition operator. The boundeness and compactness of the integral type operator JhC acting from normal weighted Bloch spaces to QT,S spaces are discussed, as well as the boundeness of the integral type operators CJh acting from normal weighted Bloch spaces to QT,S spaces. The related sufficient and necessary conditions are given.

  1. On the approximative normal values of multivalued operators in topological vector space

    International Nuclear Information System (INIS)

    Nguyen Minh Chuong; Khuat van Ninh

    1989-09-01

    In this paper the problem of approximation of normal values of multivalued linear closed operators from topological vector Mackey space into E-space is considered. Existence of normal value and convergence of approximative values to normal value are proved. (author). 4 refs

  2. Multiple Attribute Decision-Making Methods Based on Normal Intuitionistic Fuzzy Interaction Aggregation Operators

    Directory of Open Access Journals (Sweden)

    Peide Liu

    2017-11-01

    Full Text Available Normal intuitionistic fuzzy numbers (NIFNs, which combine the normal fuzzy number (NFN with intuitionistic number, can easily express the stochastic fuzzy information existing in real decision making, and power-average (PA operator can consider the relationships of different attributes by assigned weighting vectors which depend upon the input arguments. In this paper, we extended PA operator to process the NIFNs. Firstly, we defined some basic operational rules of NIFNs by considering the interaction operations of intuitionistic fuzzy sets (IFSs, established the distance between two NIFNs, and introduced the comparison method of NIFNs. Then, we proposed some new aggregation operators, including normal intuitionistic fuzzy weighted interaction averaging (NIFWIA operator, normal intuitionistic fuzzy power interaction averaging (NIFPIA operator, normal intuitionistic fuzzy weighted power interaction averaging (NIFWPIA operator, normal intuitionistic fuzzy generalized power interaction averaging (NIFGPIA operator, and normal intuitionistic fuzzy generalized weighted power interaction averaging (NIFGWPIA operator, and studied some properties and some special cases of them. Based on these operators, we developed a decision approach for multiple attribute decision-making (MADM problems with NIFNs. The significant characteristics of the proposed method are that: (1 it is easier to describe the uncertain information than the existing fuzzy sets and stochastic variables; (2 it used the interaction operations in part of IFSs which could overcome the existing weaknesses in operational rules of NIFNs; (3 it adopted PA operator which could relieve the influence of unreasonable data given by biased decision makers; and (4 it made the decision-making results more flexible and reliable because it was with generalized parameter which could be regard as the risk attitude value of decision makers. Finally, an illustrative example is given to verify its feasibility

  3. 75 FR 70090 - Special Conditions: Bombardier Inc. Model CL-600-2E25 Airplane, Operation Without Normal...

    Science.gov (United States)

    2010-11-17

    ... Airplane, Operation Without Normal Electrical Power AGENCY: Federal Aviation Administration (FAA), DOT... without normal electrical power,'' requires safe operation in VFR conditions for at least five minutes with inoperative normal electrical power. The applicable airworthiness regulations do not contain...

  4. Physics of collisionless scrape-off-layer plasma during normal and off-normal Tokamak operating conditions.

    Energy Technology Data Exchange (ETDEWEB)

    Hassanein, A.; Konkashbaev, I.

    1999-03-15

    The structure of a collisionless scrape-off-layer (SOL) plasma in tokamak reactors is being studied to define the electron distribution function and the corresponding sheath potential between the divertor plate and the edge plasma. The collisionless model is shown to be valid during the thermal phase of a plasma disruption, as well as during the newly desired low-recycling normal phase of operation with low-density, high-temperature, edge plasma conditions. An analytical solution is developed by solving the Fokker-Planck equation for electron distribution and balance in the SOL. The solution is in good agreement with numerical studies using Monte-Carlo methods. The analytical solutions provide an insight to the role of different physical and geometrical processes in a collisionless SOL during disruptions and during the enhanced phase of normal operation over a wide range of parameters.

  5. Power system operation with battery charge/discharge scheduling based on interval analysis

    Directory of Open Access Journals (Sweden)

    Taisuke Masuta

    2016-01-01

    Full Text Available The use of photovoltaic (PV generation forecasts in economic load dispatching control, which includes the unit commitment of conventional power plants, is essential to ensure the economic performance and the reliability of power systems. In the previous study, we developed a day-ahead charge and discharge scheduling method of battery energy storage systems based on interval analysis using prediction intervals of a PV generation forecast; this interval forecast considers forecast errors and gives not only the forecasted output but also the possible range of the actual output with a certain confidence. In this study, we evaluate the proposed scheduling method by numerical simulations in terms of the power system supply and demand operation.

  6. Cost analysis of heart transplantation from the day of operation to the day of discharge.

    Science.gov (United States)

    Saywell, R M; Woods, J R; Halbrook, H G; Jay, S J; Nyhuis, A W; Lohrman, R G

    1989-01-01

    Hospital costs from the day of transplantation to the day of discharge were examined in a consecutive series of 53 patients who underwent orthotopic heart transplantation between October 1982 and February 1987. An accounting cost methodology was used to convert billable charges, to costs for 29 separate hospital cost centers. Total cost per case has shown a statistically significant decrease of over $30,000 with no indication of a change in patient selection or a decrease in 3-month survival. Most of the cost reductions occurred in five cost centers: operating room, blood and intravenous therapy, medical supplies, heart station, and routine services, as evidenced by decreases in wages and supplies. The results support the premise that new technologies can become more cost-efficient over time and suggest that as the medical team becomes more proficient and experienced, cost reductions can become a reality.

  7. A systems integration approach to the optimum operation and scheduling of biocide usage and discharge for seawater cooling systems

    KAUST Repository

    Mahfouz, Abdullah Bin

    2012-01-01

    The objective of this work is to develop a systematic approach to the optimal design and integration of seawater cooling systems in industrial facilities along with the usage and discharge of biocides. Specifically, the paper will address the following tasks: 1 identification of the reaction pathways for the biocide from the mixing basin to the discharge points 2 kinetic modelling of the biocide and by-products throughout the process 3 a process integration framework to provide a holistic approach to optimising the design and operation of the seawater cooling systems, along with the dosage and discharge systems. A hierarchical procedure is developed to first identify design modifications for heat integration and energy efficiency. Then, a multi-period, multi-segment optimisation formulation is developed and solved to identify the optimal operation and scheduling of biocide usage and discharge. A case study is solved to illustrate the applicability of the devised approach.

  8. 46 CFR 153.1130 - Failure of slops discharge recording equipment; operating with, reporting failures, and replacing...

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Failure of slops discharge recording equipment; operating with, reporting failures, and replacing pollution equipment: Category A, B, C, D. 153.1130 Section... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations...

  9. The Domain of Normal Attraction of an Operator-Stable Law

    OpenAIRE

    Hudson, William N.; Mason, J. David; Veeh, Jerry Alan

    1983-01-01

    The idea of the domain of normal attraction was earlier extended to probabilities on a finite-dimensional inner-product space. We obtain a necessary and sufficient condition that a probability be in the domain of normal attraction of a given probability in terms of their covariance operators and of a limit involving the Levy measure. This condition appears to be the natural generalization of the corresponding univariate condition. We also show that the domains of normal attraction of two prob...

  10. Effect of Dam operation on monthly and annual trends of flow discharge in the Qom Rood Watershed, Iran

    Science.gov (United States)

    Yaghmaei, Hiva; Sadeghi, Seyed Hamidreza; Moradi, Hamidreza; Gholamalifard, Mehdi

    2018-02-01

    Trends in flow discharge, temperature and rainfall from the Qom Rood Watershed, Iran, for a period of 1979-2016 were analyzed at monthly and annual time scales. Trend analyses were conducted using the Mann-Kendall test, the double-mass curve of mean annual discharge versus rainfall, and rainfall-runoff relationship before and after the 15 Khordad Dam operation. Multiple regression of flow discharge against rainfall and temperature was used to determine the residual trend at four meteorological and hydrological stations located upstream and downstream of the Qom Rood Watershed. Results showed that the temperature at the upstream and downstream stations did not have any significant trend, but a significant decreasing trend (P Dam operation. Annual mean discharge at the upstream stations did not show a significant change before and after 15 Khordad Dam operation. However, annual flow magnitude decreased significantly by 87.5 and 81.7% in Shad Abad and KoohSefid, respectively. These results confirmed that natural driving forces did not affect flow discharge changes and the observed decreasing tendency in flow discharge at the downstream stations was due to 15 Khordad Dam, and at the upstream stations due to diversion/storage dams. These findings highlighted the role of human interference in changing the hydrologic regime in the study area based on which appropriate adaptive decisions can be made.

  11. Does arousal interfere with operant conditioning of spike-wave discharges in genetic epileptic rats?

    Science.gov (United States)

    Osterhagen, Lasse; Breteler, Marinus; van Luijtelaar, Gilles

    2010-06-01

    One of the ways in which brain computer interfaces can be used is neurofeedback (NF). Subjects use their brain activation to control an external device, and with this technique it is also possible to learn to control aspects of the brain activity by operant conditioning. Beneficial effects of NF training on seizure occurrence have been described in epileptic patients. Little research has been done about differentiating NF effectiveness by type of epilepsy, particularly, whether idiopathic generalized seizures are susceptible to NF. In this experiment, seizures that manifest themselves as spike-wave discharges (SWDs) in the EEG were reinforced during 10 sessions in 6 rats of the WAG/Rij strain, an animal model for absence epilepsy. EEG's were recorded before and after the training sessions. Reinforcing SWDs let to decreased SWD occurrences during training; however, the changes during training were not persistent in the post-training sessions. Because behavioural states are known to have an influence on the occurrence of SWDs, it is proposed that the reinforcement situation increased arousal which resulted in fewer SWDs. Additional tests supported this hypothesis. The outcomes have implications for the possibility to train SWDs with operant learning techniques. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  12. nth roots with Hilbert-Schmidt defect operator of normal contractions

    International Nuclear Information System (INIS)

    Duggal, B.P.

    1992-08-01

    Let T be a normal contraction (on a complex separable Hilbert space H into itself) with an nth root A such that the defect operator D A =(1-A*A) 1/2 is of the Hilbert-Schmidt class C 2 . Then either A is normal or A is similar to a normal contraction. In the case in which T is hyponormal, A n =T and D A is an element of C 2 , A is a ''coupling'' of a contraction similar to a normal contraction and a contraction which is the quasi-affine transform of a unilateral shift. These results are applied to prove a (Putnam-Fuglede type) commutatively theorem for operator valued roots of commutative analytic functions and hyponormal contractions T which have an nth root with Hilbert-Schmidt defect operator. 23 refs

  13. Intrinsic-normal-ordered vertex operators from the multiloop N-tachyon amplitude

    International Nuclear Information System (INIS)

    Aldazabal, G.; Nunez, C.; Bonini, M.; Iengo, R.

    1987-09-01

    We construct vertex operators for arbitrary mass level states of the closed bosonic string. Starting from a generalization of the Koba-Nielsen amplitude which is suitable for an arbitrary genus Riemann surface, we read the vertex operators from the residues of the poles for the intermediate states. Since the original expression is metric independent and normal ordered without the need of inventing any regularization scheme, our vertex operators also possess these properties. We discuss their general features. (author). 17 refs

  14. Partial Discharge Measurement in Operation: Problems with Disturbances and their Removing

    Directory of Open Access Journals (Sweden)

    Lenka Beranova

    2008-01-01

    Full Text Available Diagnostics by partial discharge measurement is a modern diagnostic method for determination of the state of insulating systems of high voltage machines and equipment. In the High Voltage Laboratory of the Czech Technical University in Prague was developed the complex measuring and evaluating system for partial discharge measurement. Unfortunately, the main problem of discharge activity measurement in practice is in electromagnetic disturbance. This article is focused on the removing this disturbance from measured data. Great problems in the evaluation of partial discharge data is in various sorts of interferences. 

  15. Benthic foraminiferal responses to operational drill cutting discharge in the SW Barents Sea - a case study.

    Science.gov (United States)

    Aagaard-Sørensen, Steffen; Junttila, Juho; Dijkstra, Noortje

    2016-04-01

    Petroleum related exploration activities started in the Barents Sea 1980, reaching 97 exploration wells drilled per January 2013. The biggest operational discharge from drilling operations in the Barents Sea is the release of drill cuttings (crushed seabed and/or bedrock) and water based drilling muds including the commonly used weighing material barite (BaSO4). Barium (Ba), a constituent of barite, does not degrade and can be used to evaluate dispersion and accumulation of drill waste. The environmental impact associated with exploration drilling within the Goliat Field, SW Barents Sea in 2006 was evaluated via a multiproxy investigation of local sediments. The sediments were retrieved in November 2014 at ~350 meters water depth and coring sites were selected at distances of 5, 30, 60, 125 and 250 meters from the drill hole in the eastward downstream direction. The dispersion pattern of drill waste was estimated via measurements of sediment parameters including grain size distribution and water content in addition to heavy metal and total organic carbon contents. The environmental impact was evaluated via micro faunal analysis based on benthic foraminiferal (marine shell bearing protists) fauna composition and concentration changes. Observing the sediment parameters, most notably Ba levels, reveals that dispersion of drill waste was limited to <125 meters from the drill site with drill waste thicknesses decreasing downstream. The abruptness and quantity of drill waste sedimentation initially smothered the foraminiferal fauna at ≤ 30 meters from the drill site, while at a distance of 60 meters, the fauna seemingly survived and bioturbation persisted. Analysis of the live (Nov 2014) foraminiferal fauna reveals a natural species composition at all distances from the drill site within the top sediments (0-5 cm core depth). Furthermore, the fossil foraminiferal fauna composition found within post-impacted top sediment sections, particularly in the cores situated at

  16. Prediction of the time-dependent failure rate for normally operating components taking into account the operational history

    Energy Technology Data Exchange (ETDEWEB)

    Vrbanic, I.; Simic, Z.; Sljivac, D. [Zagreb Univ. (Croatia). Faculty of Electrical Engineering and Computing

    2008-09-15

    The prediction of the time-dependent failure rate has been studied, taking into account the operational history of a component used in applications such as system modeling in a probabilistic safety analysis in order to evaluate the impact of equipment aging and maintenance strategies on the risk measures considered. We have selected a time-dependent model for the failure rate which is based on the Weibull distribution and the principles of proportional age reduction by equipment overhauls. Estimation of the parameters that determine the failure rate is considered, including the definition of the operational history model and likelihood function for the Bayesian analysis of parameters for normally operating repairable components. The operational history is provided as a time axis with defined times of overhauls and failures. An example for demonstration is described with prediction of the future behavior for seven different operational histories. (orig.)

  17. 33 CFR 151.66 - Operating requirements: Discharge of garbage in the Great Lakes and other navigable waters.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Operating requirements: Discharge of garbage in the Great Lakes and other navigable waters. 151.66 Section 151.66 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL...

  18. Simple eigenvectors of unbounded operators of the type “normal plus compact”

    Directory of Open Access Journals (Sweden)

    Michael Gil'

    2015-01-01

    Full Text Available The paper deals with operators of the form \\(A=S+B\\, where \\(B\\ is a compact operator in a Hilbert space \\(H\\ and \\(S\\ is an unbounded normal one in \\(H\\, having a compact resolvent. We consider approximations of the eigenvectors of \\(A\\, corresponding to simple eigenvalues by the eigenvectors of the operators \\(A_n=S+B_n\\ (\\(n=1,2, \\ldots\\, where \\(B_n\\ is an \\(n\\-dimensional operator. In addition, we obtain the error estimate of the approximation.

  19. Critical discharge at Datong for controlling operation of South-to-North Water Transfer Project in dry seasons

    Directory of Open Access Journals (Sweden)

    Wang Yigang

    2008-06-01

    Full Text Available Previous research shows that there is a strong correlation between saltwater intrusion in the Yangtze Estuary and discharge at Datong. In the near future, the discharge of the Yangtze River during dry seasons will decrease due to the construction and operation of large water diversion projects, including the South-to-North Water Transfer Project, which will further exacerbate saltwater intrusion in the estuary. In this paper, a nested 1D river network model and a 2D saltwater numerical model are used to associate saltwater intrusion in the Yangtze Estuary with different values of discharge at Datong. It is concluded that 13 000 m3/s is the critical discharge at Datong for preventing saltwater intrusion and controlling the volume of water transferred by the South-to-North Water Transfer Project. Furthermore, based on the analysis of river discharge from Datong to Xuliujing and in consideration of the influence of all of the water diversion projects, operation schemes are proposed for the Eastern Route of the South-to-North Water Transfer Project for different hydrological years.

  20. Assessment of risks of accidents and normal operation at nuclear power plants

    International Nuclear Information System (INIS)

    Savolainen, Ilkka; Vuori, Seppo.

    1977-01-01

    A probabilistic assessment model for the analysis of risks involved in the operation of nuclear power plants is described. With the computer code ARANO it is possible to estimate the health and economic consequences of reactor accidents both in probabilistic and deterministic sense. In addition the code is applicable to the calculation of individual and collective doses caused by the releases during normal operation. The estimation of release probabilities and magnitudes is not included in the model. (author)

  1. Occupational and Public Exposure During Normal Operation of Radioactive Waste Disposal Facilities

    OpenAIRE

    M. V. Vedernikova; I. A. Pron; M. N. Savkin; N. S. Cebakovskaya

    2017-01-01

    This paper focuses on occupational and public exposure during operation of disposal facilities receiving liquid and solid radioactive waste of various classes and provides a comparative analysis of the relevant doses: actual and calculated at the design stage. Occupational and public exposure study presented in this paper covers normal operations of a radioactive waste disposal facility receiving waste. Results: Analysis of individual and collective occupational doses was performed based on d...

  2. Operability of nuclear systems in normal and adverse environments. Volume 1

    International Nuclear Information System (INIS)

    1989-01-01

    These proceedings of the International Conference on Operability of nuclear systems in normal and adverse environments, Volume 1, are divided into sections bearing on: - General session: 8 conferences - Analytical approaches: 5 conferences - Environmental effects: 7 conferences - Degradation monitoring: 8 conferences - Aging and life assessment: 9 conferences - Test experience on mechanical equipment: 8 conferences - Test experience on electrical equipment: 8 conferences - Reliability studies: 8 conferences

  3. Comparative Analysis of Battery Behavior with Different Modes of Discharge for Optimal Capacity Sizing and BMS Operation

    Directory of Open Access Journals (Sweden)

    Mazhar Abbas

    2016-10-01

    Full Text Available Battery-operated systems are always concerned about the proper management and sizing of a battery. A Traditional Battery Management System (BMS only includes battery-aware task scheduling based on the discharge characteristics of a whole battery pack and do not take into account the mode of the load being served by the battery. On the other hand, an efficient and intelligent BMS should monitor the battery at a cell level and track the load with significant consideration of the load mode. Depending upon the load modes, the common modes of discharge (MOD of a battery identified so far are Constant Power Mode (CPM, Constant Current Mode (CCM and Constant Impedance Mode (CIM. This paper comparatively analyzes the discharging behavior of batteries at an individual cell level for different load modes. The difference in discharging behavior from mode to mode represents the study of the mode-dependent behavior of the battery before its deployment in some application. Based on simulation results, optimal capacity sizing and BMS operation of battery for an assumed situation in a remote microgrid has been proposed.

  4. The normalized administration of hybrid operating room: its practical application in managing multiple injuries

    International Nuclear Information System (INIS)

    Li Xue; Zhang Weiguo; Zhang Lianyang; Chen Tingjing; Chen Jinhua

    2011-01-01

    Objective: Through carrying out the normalized administration of hybrid operating room the application of the operating room is expanded to the performing of multiple injuries, and, in this way, the operative management become standardized and programmed, the cooperation and efficiency of hybrid operations for multiple injuries are improved and the surgeries can be ensured. Methods: According to the characteristics of hybrid interventional operation for multiple injuries, the basic construction of the hybrid operating room improved, the hybrid operation team was organized, and the administrative system as well as the working program were established. The green channel for rescuing patients with multiple injuries was set up. The cooperative behavior during interventional treatment for multiple injuries was specified. Results: The coordination and working efficiency of physicians, nurses, technicians and anesthetists were well improved. The qualified rate of lamina flow administration reached 100%. The success rate of the rescue of multiple injuries was increased. Conclusion: As one-stop complex interventional operation for multiple injuries is a new technique, there is no integrated administration system. Therefore, the establishment of standardized management of one-stop complex interventional operation is of great significance in guiding clinical practice. (authors)

  5. Health effects of technologies for power generation: Contributions from normal operation, severe accidents and terrorist threat

    International Nuclear Information System (INIS)

    Hirschberg, Stefan; Bauer, Christian; Burgherr, Peter; Cazzoli, Eric; Heck, Thomas; Spada, Matteo; Treyer, Karin

    2016-01-01

    As a part of comprehensive analysis of current and future energy systems we carried out numerous analyses of health effects of a wide spectrum of electricity supply technologies including advanced ones, operating in various countries under different conditions. The scope of the analysis covers full energy chains, i.e. fossil, nuclear and renewable power plants and the various stages of fuel cycles. State-of-the-art methods are used for the estimation of health effects. This paper addresses health effects in terms of reduced life expectancy in the context of normal operation as well as fatalities resulting from severe accidents and potential terrorist attacks. Based on the numerical results and identified patterns a comparative perspective on health effects associated with various electricity generation technologies and fuel cycles is provided. In particular the estimates of health risks from normal operation can be compared with those resulting from severe accidents and hypothetical terrorist attacks. A novel approach to the analysis of terrorist threat against energy infrastructure was developed, implemented and applied to selected energy facilities in various locations. Finally, major limitations of the current approach are identified and recommendations for further work are given. - Highlights: • We provide state-of-the-art comparative assessment of energy health risks. • The scope of the analysis should to the extent possible cover full energy chains. • Health impacts from normal operation dominate the risks. • We present novel approach to analysis of terrorist threat. • Limitations include technology choices, geographical coverage and terrorist issues.

  6. Application of wire electrodes in electric discharge machining of metal samples of reactor blocks of the operative atomic power station

    International Nuclear Information System (INIS)

    Gozhenko, S.V.

    2007-01-01

    Features of application of electroerosive methods are considered during the process of direct definition of properties of metal of the equipment of power units of the atomic power station. Results of development of a complex of the equipment for wire electric discharge machining of metal templet and its use are presented at the control of the basic metal of the main circulating pipelines over blocks of the atomic power station of Ukraine over long terms of operation

  7. Identification of support structure damping of a full scale offshore wind turbine in normal operation

    DEFF Research Database (Denmark)

    Koukoura, Christina; Natarajan, Anand; Vesth, Allan

    2015-01-01

    maxima of an impulse response caused by a boat impact. The result is used in the verification of the non aerodynamic damping in normal operation for low wind speeds. The auto-correlation function technique for damping estimation of a structure under ambient excitation was validated against the identified...... damping from the decaying time series. The Enhanced Frequency Domain Decomposition (EFDD) method was applied to the wind turbine response under ambient excitation, for estimation of the damping in normal operation. The aero-servo-hydro-elastic tool HAWC2 is validated with offshore foundation load...... measurements. The model was tuned to the damping values obtained from the boat impact to match the measured loads. Wind turbulence intensity and wave characteristics used in the simulations are based on site measurements. A flexible soil model is included in the analysis. The importance of the correctly...

  8. Experimental Modeling of VHTR Plenum Flows during Normal Operation and Pressurized Conduction Cooldown

    Energy Technology Data Exchange (ETDEWEB)

    Glenn E McCreery; Keith G Condie

    2006-09-01

    The Very High Temperature Reactor (VHTR) is the leading candidate for the Next Generation Nuclear Power (NGNP) Project in the U.S. which has the goal of demonstrating the production of emissions free electricity and hydrogen by 2015. The present document addresses experimental modeling of flow and thermal mixing phenomena of importance during normal or reduced power operation and during a loss of forced reactor cooling (pressurized conduction cooldown) scenario. The objectives of the experiments are, 1), provide benchmark data for assessment and improvement of codes proposed for NGNP designs and safety studies, and, 2), obtain a better understanding of related phenomena, behavior and needs. Physical models of VHTR vessel upper and lower plenums which use various working fluids to scale phenomena of interest are described. The models may be used to both simulate natural convection conditions during pressurized conduction cooldown and turbulent lower plenum flow during normal or reduced power operation.

  9. On the combinatorics of normal ordering bosonic operators and deformations of it

    CERN Document Server

    Schork, M

    2003-01-01

    Recently some combinatorial aspects for the normal ordering of powers of arbitrary monomials of boson operators were discussed. In particular, it was shown that the resulting formulae lead to generalizations of the usual Bell and Stirling numbers. In this paper these considerations are generalized to the q-deformed case. In particular, it is shown that the simplest example of this generalization leads to q-deformed Lah numbers. The connection between (generalized) Stirling and Bell numbers and matrix elements of the above-mentioned operators with respect to the usual Fock space basis and coherent states is discussed.

  10. Normal, cohyponormal and normaloid weighted composition operators on the Hardy and weighted Bergman spaces

    OpenAIRE

    Fatehi, Mahsa; Shaabani, Mahmood Haji

    2015-01-01

    If $\\psi$ is analytic on the open unit disk $\\mathbb{D}$ and $\\varphi$ is an analytic self-map of $\\mathbb{D}$, the weighted composition operator $C_{\\psi,\\varphi}$ is defined by $C_{\\psi,\\varphi}f(z)=\\psi(z)f (\\varphi (z))$, when $f$ is analytic on $\\mathbb{D}$. In this paper, we study normal, cohyponormal, hyponormal and normaloid weighted composition operators on the Hardy and weighted Bergman spaces. First, for some weighted Hardy spaces $H^{2}(\\beta)$, we prove that if $C_{\\psi,\\varphi}$...

  11. Study of a contracted glow in low-frequency plasma-jet discharges operating with argon

    Energy Technology Data Exchange (ETDEWEB)

    Minotti, F.; Giuliani, L.; Xaubet, M.; Grondona, D. [Departamento de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Buenos Aires, C1428EHA, Buenos Aires, Argentina and Instituto de Física del Plasma (INFIP), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Universidad de Buenos Aires - UBA, C1428EHA, Buenos Aires (Argentina)

    2015-11-15

    In this work, we present an experimental and theoretical study of a low frequency, atmospheric plasma-jet discharge in argon. The discharge has the characteristics of a contracted glow with a current channel of submillimeter diameter and a relatively high voltage cathode layer. In order to interpret the measurements, we consider the separate modeling of each region of the discharge: main channel and cathode layer, which must then be properly matched together. The main current channel was modeled, extending a previous work, as similar to an arc in which joule heating is balanced by lateral heat conduction, without thermal equilibrium between electrons and heavy species. The cathode layer model, on the other hand, includes the emission of secondary electrons by ion impact and by additional mechanisms, of which we considered emission due to collision of atoms excited at metastable levels, and field-enhanced thermionic emission (Schottky effect). The comparison of model and experiment indicates that the discharge can be effectively sustained in its contracted form by the secondary electrons emitted by collision of excited argon atoms, whereas thermionic emission is by far insufficient to provide the necessary electrons.

  12. Operating modes of a hydrogen ion source based on a hollow-cathode pulsed Penning discharge.

    Science.gov (United States)

    Oks, E M; Shandrikov, M V; Vizir, A V

    2016-02-01

    An ion source based on a hollow-cathode Penning discharge was switched to a high-current pulsed mode (tens of amperes and tens of microseconds) to produce an intense hydrogen ion beam. With molecular hydrogen (H2), the ion beam contained three species: H(+), H2(+), and H3(+). For all experimental conditions, the fraction of H2 (+) ions in the beam was about 10 ÷ 15% of the total ion beam current and varied little with ion source parameters. At the same time, the ratio of H(+) and H3(+) depended strongly on the discharge current, particularly on its distribution in the gap between the hollow and planar cathodes. Increasing the discharge current increased the H(+) fraction in ion beam. The maximum fraction of H(+) reached 80% of the total ion beam current. Forced redistribution of the discharge current in the cathode gap for increasing the hollow cathode current could greatly increase the H3(+) fraction in the beam. At optimum parameters, the fraction of H3(+) ions reached 60% of the total ion beam current.

  13. Ozone generation in a kHz-pulsed He-O2 capillary dielectric barrier discharge operated in ambient air

    Science.gov (United States)

    Sands, Brian L.; Ganguly, Biswa N.

    2013-12-01

    The generation of reactive oxygen species using nonequilibrium atmospheric pressure plasma jet devices has been a subject of recent interest due to their ability to generate localized concentrations from a compact source. To date, such studies with plasma jet devices have primarily utilized radio-frequency excitation. In this work, we characterize ozone generation in a kHz-pulsed capillary dielectric barrier discharge configuration comprised of an active discharge plasma jet operating in ambient air that is externally grounded. The plasma jet flow gas was composed of helium with an admixture of up to 5% oxygen. A unipolar voltage pulse train with a 20 ns pulse risetime was used to drive the discharge at repetition rates between 2-25 kHz. Using UVLED absorption spectroscopy centered at 255 nm near the Hartley-band absorption peak, ozone was detected over 1 cm from the capillary axis. We observed roughly linear scaling of ozone production with increasing pulse repetition rate up to a "turnover frequency," beyond which ozone production steadily dropped and discharge current and 777 nm O(5P→5S°) emission sharply increased. The turnover in ozone production occurred at higher pulse frequencies with increasing flow rate and decreasing applied voltage with a common energy density of 55 mJ/cm3 supplied to the discharge. The limiting energy density and peak ozone production both increased with increasing O2 admixture. The power dissipated in the discharge was obtained from circuit current and voltage measurements using a modified parallel plate dielectric barrier discharge circuit model and the volume-averaged ozone concentration was derived from a 2D ozone absorption measurement. From these measurements, the volume-averaged efficiency of ozone production was calculated to be 23 g/kWh at conditions for peak ozone production of 41 mg/h at 11 kV applied voltage, 3% O2, 2 l/min flow rate, and 13 kHz pulse repetition rate, with 1.79 W dissipated in the discharge.

  14. Newton Leibniz integration for ket-bra operators in quantum mechanics (V)—Deriving normally ordered bivariate-normal-distribution form of density operators and developing their phase space formalism

    Science.gov (United States)

    Fan, Hong-yi

    2008-06-01

    We show that Newton-Leibniz integration over Dirac's ket-bra projection operators with continuum variables, which can be performed by the technique of integration within ordered product (IWOP) of operators [Hong-yi Fan, Hai-liang Lu, Yue Fan, Ann. Phys. 321 (2006) 480], can directly recast density operators and generalized Wigner operators into normally ordered bivariate-normal-distribution form, which has resemblance in statistics. In this way the phase space formalism of quantum mechanics can be developed. The Husimi operator, entangled Husimi operator and entangled Wigner operator for entangled particles with different masses are naturally introduced by virtue of the IWOP technique, and their physical meanings are explained.

  15. Carbon source from the toroidal pumped limiter during long discharge operation in Tore Supra

    International Nuclear Information System (INIS)

    Dufour, E.; Brosset, C.; Lowry, C.; Bucalossi, J.; Chappuis, P.; Corre, Y.; Desgranges, C.; Guirlet, R.; Gunn, J.; Loarer, T.; Mitteau, R.; Monier-Garbet, P.; Pegourie, B.; Reichle, R.; Thomas, P.; Tsitrone, E.; Hogan, J.; Roubin, P.; Martin, C.; Arnas, C.

    2005-01-01

    A better understanding of deuterium retention mechanisms requires the knowledge of carbon sources in Tore-Supra. The main source of carbon in the vacuum vessel during long discharges is the toroidal pumped limiter (TPL). This work is devoted to the experimental characterisation of the carbon source from the TPL surface during long discharges using a visible spectroscopy diagnostic. Moreover, we present an attempt to perform a carbon balance over a typical campaign and we discuss it with regards to the deuterium in-vessel inventory deduced from particle balance and the deuterium content of the deposited layers. The study shows that only a third of the estimated deuterium trapped in the vessel is trapped in the carbon deposits. Thus, in the present state of our knowledge and characterisation of the permanent retention, one has to search for mechanisms other than co-deposition to explain the deuterium retention in Tore Supra. (A.C.)

  16. Pellet cladding interaction (PCI) fuel duty during normal operation of ASEA-ATOM BWRs

    International Nuclear Information System (INIS)

    Vaernild, O.; Olsson, S.

    1983-01-01

    Local power changes may under special conditions cause PCI fuel failures in a power reactor. By restricting the local power increase rate in certain situations it is possible to prevent PCI failures. Fine motion control rod drives, large operating range of the main recirculation pumps and an advanced burnable absorber design have minimized the impact of the PCI restrictions. With current ICFM schemes the power of an assembly is due to the burnup of the gadolinia gradually increasing during the first cycle of operation. After this the power is essentially decreasing monotonously during the remaining life of the assembly. Some assemblies are for short burnup intervals operated at very low power in control cells. The control rods in these cells may however be withdrawn without restrictions leading to energy production losses. Base load operation would in the normal case lead to very minor PCI loads on the fuel regardless of any PCI related operating restrictions. At the return to full power after a short shutdown or in connection with load follow operation, the xenon transient may cause PCI loads on the fuel. To avoid this a few hoursholdtime before going back to full power is recommended. (author)

  17. Corrective action plan for CAU Number 339: Area 12 Fleet Operations, Steam Cleaning Discharge Area, Nevada Test Site

    International Nuclear Information System (INIS)

    1997-05-01

    The purpose of this Corrective Action Plan (CAP) is to provide the method for implementing the corrective action alternative as provided in the Corrective Action Decision Document (CADD). Detailed information of the site history and results of previous characterizations can be found in the Work Plan, the Preliminary Investigation Report, and the Phase 2 Characterization Report. Previous characterization investigations were completed as a condition of the Temporary Water Pollution Control Permit issued by the Nevada Division of Environmental Protection (NDEP) on July 14, 1992. The scope of this report is to prepare a CAP based upon the selected remedial alternative for closure of the Area 12, Building 12-16 Fleet Operations steam cleaning discharge area. The effluent discharge area has been impacted by volatile organic compounds (VOCs) and total petroleum hydrocarbons (TPH) as oil. The maximum hydrocarbon and VOC concentrations detected in the Preliminary and Phase 2 Site Characterization Investigations are summarized

  18. Axial mercury segregation in direct current operated low-pressure argon-mercury gas discharge: Part II. Model

    International Nuclear Information System (INIS)

    Gielen, John W A M; Groot, Simon de; Dijk, Jan van; Mullen, Joost J A M van der

    2004-01-01

    In a previous paper we had presented experimental results on mercury segregation due to cataphoresis in direct current operated low-pressure argon-mercury gas discharges. In this paper, we present our model to describe cataphoretic segregation in argon (or another noble gas)-mercury discharges. The model is based on the balance equations for mass and momentum and includes electrophoresis effects of electrons on mercury. Good agreement is found between the experimental results and model calculations. The model confirms our experimental observation that the mercury vapour pressure gradient depends on the local mercury vapour pressure. Furthermore, the model predicts the reversal of the direction of the transport of mercury under certain conditions (the phenomenon known as retrograde cataphoresis)

  19. Mathematical model and computer code for coated particles performance at normal operating conditions

    International Nuclear Information System (INIS)

    Golubev, I.; Kadarmetov, I.; Makarov, V.

    2002-01-01

    Computer modeling of thermo-mechanical behavior of coated particles during operating both at normal and off-normal conditions has a very significant role particularly on a stage of new reactors development. In Russia a big experience has been accumulated on fabrication and reactor tests of CP and fuel elements with UO 2 kernels. However, this experience cannot be using in full volume for development of a new reactor installation GT-MHR. This is due to very deep burn-up of the fuel based on plutonium oxide (up to 70% fima). Therefore the mathematical modeling of CP thermal-mechanical behavior and failure prediction becomes particularly important. The authors have a clean understanding that serviceability of fuel with high burn-ups are defined not only by thermo-mechanics, but also by structured changes in coating materials, thermodynamics of chemical processes, 'amoeba-effect', formation CO etc. In the report the first steps of development of integrate code for numerical modeling of coated particles behavior and some calculating results concerning the influence of various design parameters on fuel coated particles endurance for GT-MHR normal operating conditions are submitted. A failure model is developed to predict the fraction of TRISO-coated particles. In this model it is assumed that the failure of CP depends not only on probability of SiC-layer fracture but also on the PyC-layers damage. The coated particle is considered as a uniform design. (author)

  20. Normally ordering the Dirac's radial momentum operator and the power of radial coordinate operators by virtue of the IWOP technique

    Energy Technology Data Exchange (ETDEWEB)

    Fan Hongyi [CCAST (World Laboratory), Beijing (China); Department of Material Science and Engineering, University of Science and Technology of China, Hefei, Anhui (China); Chen Junhua [Special Class of Gifted Young, University of Science and Technology of China, Hefei, Anhui (China)

    2001-12-14

    By virtue of the technique of integration within an ordered product of operators we derive the normal ordering expansion of the Dirac's radial momentum operator. To realize this goal, we also derive some operator identities of the power of radial coordinate operators. They are useful in calculating expectation values in the coherent state. (author)

  1. Operative findings of conductive hearing loss with intact tympanic membrane and normal temporal bone computed tomography.

    Science.gov (United States)

    Kim, Se-Hyung; Cho, Yang-Sun; Kim, Hye Jeong; Kim, Hyung-Jin

    2014-06-01

    Despite recent technological advances in diagnostic methods including imaging technology, it is often difficult to establish a preoperative diagnosis of conductive hearing loss (CHL) in patients with an intact tympanic membrane (TM). Especially, in patients with a normal temporal bone computed tomography (TBCT), preoperative diagnosis is more difficult. We investigated middle ear disorders encountered in patients with CHL involving an intact TM and normal TBCT. We also analyzed the surgical results with special reference to the pathology. We reviewed the medical records of 365 patients with intact TM, who underwent exploratory tympanotomy for CHL. Fifty nine patients (67 ears, eight bilateral surgeries) had a normal preoperative TBCT findings reported by neuro-radiologists. Demographic data, otologic history, TM findings, preoperative imaging findings, intraoperative findings, and pre- and postoperative audiologic data were obtained and analyzed. Exploration was performed most frequently in the second and fifth decades. The most common postoperative diagnosis was stapedial fixation with non-progressive hearing loss. The most commonly performed hearing-restoring procedure was stapedotomy with piston wire prosthesis insertion. Various types of hearing-restoring procedures during exploration resulted in effective hearing improvement, especially with better outcome in the ossicular chain fixation group. In patients with CHL who have intact TM and normal TBCT, we should consider an exploratory tympanotomy for exact diagnosis and hearing improvement. Information of the common operative findings from this study may help in preoperative counseling.

  2. Occupational and Public Exposure During Normal Operation of Radioactive Waste Disposal Facilities

    Directory of Open Access Journals (Sweden)

    M. V. Vedernikova

    2017-01-01

    Full Text Available This paper focuses on occupational and public exposure during operation of disposal facilities receiving liquid and solid radioactive waste of various classes and provides a comparative analysis of the relevant doses: actual and calculated at the design stage. Occupational and public exposure study presented in this paper covers normal operations of a radioactive waste disposal facility receiving waste. Results: Analysis of individual and collective occupational doses was performed based on data collected during operation of near-surface disposal facilities for short-lived intermediate-, lowand very low-level waste in France, as well as nearsurface disposal facilities for long-lived waste in Russia. Further analysis of occupational and public doses calculated at the design stage was completed covering a near-surface disposal facility in Belgium and deep disposal facilities in the United Kingdom and the Nizhne-Kansk rock massive (Russia. The results show that engineering and technical solutions enable almost complete elimination of internal occupational exposure, whereas external exposure doses would fall within the range of values typical for a basic nuclear facility. Conclusion: radioactive waste disposal facilities being developed, constructed and operated meet the safety requirements effective in the Russian Federation and consistent with relevant international recommendations. It has been found that individual occupational exposure doses commensurate with those received by personnel of similar facilities abroad. Furthermore, according to the forecasts, mean individual doses for personnel during radioactive waste disposal would be an order of magnitude lower than the dose limit of 20 mSv/year. As for the public exposure, during normal operation, potential impact is virtually impossible by delaminating boundaries of a nuclear facility sanitary protection zone inside which the disposal facility is located and can be solely attributed to the use

  3. Thermal loads on tokamak plasma-facing components during normal operation and disruptions

    International Nuclear Information System (INIS)

    McGrath, R.T.

    1990-01-01

    Power loadings experienced by tokamak plasma-facing components during normal operation and during off-normal events are discussed. A model for power and particle flow in the tokamak boundary layer is presented and model predictions are compared to infrared measurements of component heating. The inclusion of the full three-dimensional geometry of the components and of the magnetic flux surface is very important in the modeling. Experimental measurements show that misalignment of component armour tile surfaces by only a millimeter can lead to significant localized heating. An application to the design of plasma-facing components for future machines is presented. Finally, thermal loads expected during tokamak disruptions are discussed. The primary problems are surface melting and vaporization due to localized intense heating during the disruption thermal quench and volumetric heating of the component armour and structure due to localised impact of runaway electrons. (author)

  4. An estimation of population doses from a nuclear power plant during normal operation

    International Nuclear Information System (INIS)

    Nowicki, K.

    1975-07-01

    A model is presented for estimation of the potential submersion and inhalation radiation doses to people located within a distance of 1000 km from a nuclear power plant during normal operation. The model was used to calculate doses for people living 200-1000 km from hypothetical nuclear power facility sited near the geographical centre of Denmark. Two kinds of sources are considered for this situation: - unit release of 15 isotopes of noble gases and iodines, - effluent releases from two types of 1000 MWe Light Water Power Reactors: PWR and BWR. Parameter variations were made and analyzed in order to obtain a better understanding of the mechanisms of the model. (author)

  5. Development of dose assessment code for release of tritium during normal operation of nuclear power plants

    International Nuclear Information System (INIS)

    Duran, J.; Malatova, I.

    2009-01-01

    A computer code PTM H TO has been developed to assess tritium doses to the general public. The code enables to simulate the behavior of tritium in the environment released into the atmosphere under normal operation of nuclear power plants. Code can calculate the doses for the three chemical and physical forms: tritium gas (HT), tritiated water vapor and water drops (HTO). The models in this code consist of the tritium transfer model including oxidation of HT to HTO and reemission of HTO from soil to the atmosphere, and the dose calculation model

  6. Jules Horowitz Reactor: Organisation for the Preparation of the Commissioning Phase and Normal Operation

    Energy Technology Data Exchange (ETDEWEB)

    Estrade, J.; Fabre, J. L.; Marcille, O. [French Alternative Energies end Atomic Energy Commission, Provence (France)

    2013-07-01

    The Jules Horowitz Reactor (JHR) is a new modern Material Testing Reactor (MTR) currently under construction at CEA Cadarache research centre in the south of France. It will be a major research facility in support to the development and the qualification of materials and fuels under irradiation with sizes and environment conditions relevant for nuclear power plants in order to optimise and demonstrate safe operations of existing power reactors as well as to support future reactors design. It will represent also an important research infrastructure for scientific studies dealing with material and fuel behaviour under irradiation. The JHR will contribute also to secure the production of radioisotope for medical application. This is a key public health stake. The construction of JHR which started in 2007 is going-on with target of commissioning by the end of 2017. The design of the reactor provides modern experimental capacity in support to R and D programs for the nuclear energy for the next 60 years. In parallel to the facility construction, the preparation of the future staff and of the organisation to operate the reactor safely, reliably and efficiently is an important issue. In this framework, many actions are in progress to elaborate: Ο the staffing and the organisational structure for the commissioning test phases and also for normal operation, Ο the documentation in support to the reactor operation (safety analysis report, general operating rules, procedures, instructions, ···), Ο the maintenance, in service and periodic test programs, Ο staff training programs by using dedicated facilities (simulator, ···) Ο commissioning test programs for ensuring that the layout of systems and subcomponents is completed in accordance with the design requirements, the specification performances and the safety criteria. These commissioning tests will also be helpful for transferring the knowledge on the installed systems to the operating group. This paper gives the

  7. LHC Beam Dump Design Study - Part III : Off-normal operating conditions

    CERN Document Server

    Bruno, L; Ross, M; Sala, P

    2000-01-01

    The LHC beam dump design study has been preliminarily substantiated by energy deposition simulations (Part I) and heat transfer analyses (Part II). The present report is devoted to the abnormal operating conditions induced by a malfunction of the beam diluters. A general approach to the analysis of off-normal operation is presented, which is derived from standard design norms adopted in the nuclear industry. Attention is focused mainly on the carbon core, which is longitudinally split into segments of different density in order to better distribute the deposited energy. The maximum energy density it absorbs decreases by at least 33%, compared to a uniform standard density carbon core. This structure may sustain any partial sweep failure without major damage, up to the ultimate beam intensity and energy. To minimise the risks inherent in a fully unswept beam, a sacrificial graphite mandrel will be placed on the core axis, surrounded by a thick high strength carbon-carbon composite tube. With this arrangement, ...

  8. Corrective Action Decision Document (CADD), Area 12 fleet operations steam cleaning discharge area, Nevada Test Site Corrective Action Unit 339

    Energy Technology Data Exchange (ETDEWEB)

    Bonn, J.F.

    1996-12-01

    This Corrective Action Decision Document (CADD) incorporates the methodology used for evaluating the remedial alternatives completed for a former steam cleaning discharge area at the Nevada Test Site (NTS). The former steam cleaning site is located in Area 12, east of the Fleet Operations Building 12-16. The discharge area has been impacted by Resource Conservation and Recovery Act (RCRA) F Listed volatile organic compounds (VOCs) and petroleum hydrocarbons waste. Based upon these findings, resulting from Phase 1 and Phase 2 site investigations, corrective action is required at the site. To determine the appropriate corrective action to be proposed, an evaluation of remedial alternatives was completed. The evaluation was completed using a Corrective Measures Study (CMS). Based on the results of the CMS, the favored closure alternative for the site is plugging the effluent discharge line, removing the sandbagged barrier, completing excavation of VOC impacted soils, and fencing the soil area impacted by total petroleum hydrocarbons (TPH), east of the discharge line and west of the soil berm. Management of the F Listed VOCs are dictated by RCRA. Due to the small volume of impacted soil, excavation and transportation to a Treatment Storage and Disposal Facility (TSDF) is the most practical method of management. It is anticipated that the TPH (as oil) impacted soils will remain in place based upon; the A through K Analysis, concentrations detected (maximum 8,600 milligrams per kilogram), expected natural degradation of the hydrocarbons over time, and the findings of the Phase 2 Investigation that vertical migration has been minimal.

  9. Validation of mathematical models for predicting the swirling flow and the vortex rope in a Francis turbine operated at partial discharge

    DEFF Research Database (Denmark)

    Kuibin, P.A.; Okulov, Valery; Susan-Resiga, R.F.

    2010-01-01

    The vortex rope in a hydro turbine draft tube is one the main and strong sources of pulsations in non-optimal modes of hydro turbine operation. We examine the case of a Francis turbine model operated at partial discharge, where a strong precessing vortex rope is developed in the discharge cone do...... several orders of magnitude less than the current approaches of simulating the complex turbine flow....

  10. The success of 6-hour hospital discharge on patients having vaginal repair operations using a new conscious sedation technique.

    Science.gov (United States)

    Hill, N; Gupta, A; Zakaryan, A; Morey, R

    2011-01-01

    Anterior and posterior repair are standard surgical techniques for treatment of vaginal prolapse. These procedures are performed traditionally under general anaesthetic or spinal anaesthetic and usually require overnight admission in the hospital. We describe our case series of 40 patients who underwent anterior (18/40), posterior (20/40) or combined repair (2/40) under local anaesthetic and conscious sedation (Remifentanyl). The majority (35/40) were performed in the day-case surgery unit and 95% patients were discharged within 6 hours of the operation, with no complications. All the patients were satisfied with the anaesthetic technique. We concluded that our technique of vaginal repair avoids the risk of general and spinal anaesthetic. The majority of operations can be performed as day cases with good patient satisfaction and without increasing risks to the patients. This technique has potential significant financial saving for the hospitals.

  11. On the Similarity of Sturm-Liouville Operators with Non-Hermitian Boundary Conditions to Self-Adjoint and Normal Operators

    Czech Academy of Sciences Publication Activity Database

    Krejčiřík, David; Siegl, Petr; Železný, Jakub

    2014-01-01

    Roč. 8, č. 1 (2014), s. 255-281 ISSN 1661-8254 R&D Projects: GA MŠk LC06002; GA MŠk LC527; GA ČR GAP203/11/0701 Grant - others:GA ČR(CZ) GD202/08/H072 Institutional support: RVO:61389005 Keywords : Sturm-Liouville operators * non-symmetric Robin boundary conditions * similarity to normal or self-adjoint operators * discrete spectral operator * complex symmetric operator * PT-symmetry * metric operator * C operator * Hilbert-Schmidt operators Subject RIV: BE - Theoretical Physics Impact factor: 0.545, year: 2014

  12. Elbow replacement - discharge

    Science.gov (United States)

    Total elbow arthroplasty - discharge; Endoprosthetic elbow replacement - discharge ... Pain is normal after elbow replacement surgery. It should get better over time. Your doctor will give you a prescription for pain medicine. Get it filled when ...

  13. Operational river discharge forecasting in poorly gauged basins: the Kavango River Basin case study

    DEFF Research Database (Denmark)

    Bauer-Gottwein, Peter; Jensen, Iris Hedegaard; Guzinski, R.

    2014-01-01

    assimilation techniques. However, few studies have attempted to develop operational probabilistic forecasting approaches for large and poorly gauged river basins. This study is funded by the European Space Agency under the TIGER-NET project. The objective of TIGER-NET is to develop open-source software tools...

  14. Does arousal interfere with operant conditioning of spike-wave discharges in genetic epileptic rats?

    NARCIS (Netherlands)

    Osterhagen, L.; Breteler, M.H.M.; Luijtelaar, E.L.J.M. van

    2010-01-01

    One of the ways in which brain computer interfaces can be used is neurofeedback (NF). Subjects use their brain activation to control an external device, and with this technique it is also possible to learn to control aspects of the brain activity by operant conditioning. Beneficial effects of NF

  15. 76 FR 78599 - National Pollutant Discharge Elimination System (NPDES) Concentrated Animal Feeding Operation...

    Science.gov (United States)

    2011-12-19

    ... 3334, 1301 Constitution Ave. NW., Washington, DC 20460. The Public Reading Room is open from 8:30 a.m... Reading Room is (202) 566-1744, and the telephone number for the Water Docket is (202) 566-2426. FOR...''). An animal feeding operation (AFO) is a CAFO if it meets the regulatory definition of a Large or...

  16. Normal return and efficient operation of the electric grid monopolies; Normalavkastning og effektiv drift for nettmonopolene

    Energy Technology Data Exchange (ETDEWEB)

    Skjeret, Frode Andre

    2001-07-01

    This report deals with the size of the risk premium for electric grid operation in Norway. The size of the companies' risk premium must reflect the market requirements on return compensation (for normal investment risk), adjusted for the return risk for this type of enterprise. The return risk of the grid companies is discussed using two approaches, one theoretical and one empirical. This implies an empirical analysis of comparable foreign companies and an examination of the Norwegian regulatory regime. It is concluded that the regulatory authority is using too small an estimate for the risk premium when determining the capital income of the Norwegian utilities. The report also discusses the principles for valuation of the capital base.

  17. Environmental dose assessment methods for normal operations at DOE nuclear sites

    Energy Technology Data Exchange (ETDEWEB)

    Strenge, D.L.; Kennedy, W.E. Jr.; Corley, J.P.

    1982-09-01

    Methods for assessing public exposure to radiation from normal operations at DOE facilities are reviewed in this report. The report includes a discussion of environmental doses to be calculated, a review of currently available environmental pathway models and a set of recommended models for use when environmental pathway modeling is necessary. Currently available models reviewed include those used by DOE contractors, the Environmental Protection Agency (EPA), the Nuclear Regulatory Commission (NRC), and other organizations involved in environmental assessments. General modeling areas considered for routine releases are atmospheric transport, airborne pathways, waterborne pathways, direct exposure to penetrating radiation, and internal dosimetry. The pathway models discussed in this report are applicable to long-term (annual) uniform releases to the environment: they do not apply to acute releases resulting from accidents or emergency situations.

  18. Environmental dose-assessment methods for normal operations at DOE nuclear sites

    International Nuclear Information System (INIS)

    Strenge, D.L.; Kennedy, W.E. Jr.; Corley, J.P.

    1982-09-01

    Methods for assessing public exposure to radiation from normal operations at DOE facilities are reviewed in this report. The report includes a discussion of environmental doses to be calculated, a review of currently available environmental pathway models and a set of recommended models for use when environmental pathway modeling is necessary. Currently available models reviewed include those used by DOE contractors, the Environmental Protection Agency (EPA), the Nuclear Regulatory Commission (NRC), and other organizations involved in environmental assessments. General modeling areas considered for routine releases are atmospheric transport, airborne pathways, waterborne pathways, direct exposure to penetrating radiation, and internal dosimetry. The pathway models discussed in this report are applicable to long-term (annual) uniform releases to the environment: they do not apply to acute releases resulting from accidents or emergency situations

  19. The effect of UV treatment on highly polluted and normal operated swimming pools

    DEFF Research Database (Denmark)

    Spiliotopoulou, Aikaterini; Kaarsholm, Kamilla Marie Speht; Andersen, Henrik Rasmus

    2017-01-01

    Water samples from 2 indoor public swimming pool facilities with significantly different organic matter concentrations in the recirculation were tested to evaluate UV-induced effects on water chemistry. The aim of the study was to investigate the impact of poor water quality due to increased...... organic carbon (TOC) and the potential effect of increased nitrate concentration on disinfection by-product (DBP) formation in pool water. Concentration change on total trihalomethanes (TTHM) was investigated utilising medium pressure UV treatment in conjunction with chlorine. Post-UV chlorine consumption...... increased, UV dose-dependently. The post-UV chlorination clearly induced TTHM formation in both polluted and normal operated pools. However, elevated TOC concentration did not increase significantly the DBP formation. Regarding the brominated fraction of the halogens in the formed TTHMs, it appeared...

  20. Comparison of Pre-operative Central Corneal Thickness in Pediatric Cataract Cases versus Normal

    International Nuclear Information System (INIS)

    Khan, S.; Ali, M.; Zaheer, N.

    2014-01-01

    Objective: To compare the pre-operative central corneal thickness (CCT) in paediatric cataract patients with reference to normal control group. Study Design: A case control study. Place and Duration of Study: Paediatric Ophthalmology Clinic of Al-Shifa Trust Eye Hospital (ASTEH), Rawalpindi, from November 2009 to May 2010. Methodology: The study included 116 subjects with equal number of cases and controls. Demographic profile of all the subjects was noted followed by history and detailed ophthalmic examination. CCT was measured using an ultrasonic pachymeter (model Pac Scan 300). The mean of three measurements from the central cornea were recorded in microns. Results were analyzed using SPSS version 17.0. Results: Mean CCT values of the cases was 566.83 +- 37.646 microns while the control group had a mean CCT of 535.81 +- 24.466 microns. Difference between the CCT values of the two groups was highly significant (p < 0.001). Conclusion: Eyes with congenital cataracts have greater CCT values as compared to normal paediatric population. This factor must be kept in mind while interpreting intra-ocular pressure in such patients. (author)

  1. STUDY ON ENERGY EXCHANGE PROCESSES IN NORMAL OPERATION OF METRO ROLLING STOCK WITH REGENERATIVE BRAKING SYSTEMS

    Directory of Open Access Journals (Sweden)

    A. O. Sulym

    2017-10-01

    Full Text Available Purpose. The analysis of the existing studies showed that the increasing of energy efficiency of metro rolling stock becomes especially important and requires timely solutions. It is known that the implementation of regenerative braking systems on rolling stock will allow significantly solving this problem. It was proved that one of the key issues regarding the introduction of the above-mentioned systems is research on efficient use of electric energy of regenerative braking. The purpose of the work is to evaluate the amount of excessive electric power of regenerative braking under normal operation conditions of the rolling stock with regenerative braking systems for the analysis of the energy saving reserves. Methodology. Quantifiable values of electrical energy consumed for traction, returned to the contact line and dissipated in braking resistors (excessive energy are determined using results of experimental studies of energy exchange processes under normal operating conditions of metro rolling stock with regenerative systems. Statistical methods of data processing were applied as well. Findings. Results of the studies analysis of metro rolling stock operation under specified conditions in Sviatoshinsko-Brovarskaia line of KP «Kyiv Metro system» stipulate the following: 1 introduction of regenerative braking systems into the rolling stock allows to return about 17.9-23.2% of electrical energy consumed for traction to the contact line; 2 there are reserves for improving of energy efficiency of rolling stock with regenerative systems at the level of 20.2–29.9 % of electrical energy consumed for traction. Originality. For the first time, it is proved that the most significant factor that influences the quantifiable values of the electrical energy regeneration is a track profile. It is suggested to use coefficients which indicate the amount and reserves of unused (excessive electrical energy for quantitative evaluation. Studies on

  2. Hybrid radiation background monitoring in operational control and forecasting of environmental contamination by nuclear power station discharges

    International Nuclear Information System (INIS)

    Ermeev, I.S.; Eremenko, V.A.; Makarov, Y.A.; Matueev, V.V.; Zhernov, V.S.

    1986-01-01

    Rapid developments in nuclear power have stimulated research on monitoring and forecasting environmental radiation pollution (ERP), and in particular the amounts, compositions, and distributions of radionuclides in the environment. A conceptual model is presented for hybrid environmental radiation pollution monitoring. When there is an emergency, the model operates in a fashion most closely corresponding to the actual meteorological conditions, and the ERP data given by the model enable one to distinguish changes due to the man-made component from random fluctuations in the natural background. The measurement system in general includes mobile and stationary data-acquisition facilities linked by wire or radio to the central point. The system also accumulates and stores data on the radiation environment, which are edited on the basis of radioactive, chemical, and other transformations. The purpose of hybrid monitoring is ultimately to analyze trends in order to detect elevated discharges and thus to output data to the regional monitoring system

  3. Barium Depletion in the NSTAR Discharge Cathode After 30,000 Hours of Operation

    Science.gov (United States)

    Polk, James E.; Capece, Angela M.; Mikellides, Ioannis G.; Katz, Ira

    2010-01-01

    Dispenser hollow cathodes rely on a consumable supply of barium released by impregnant materials in the pores of a tungsten matrix to maintain a low work function surface. Examinations of cathode inserts from long duration ion engine tests show deposits of tungsten at the downstream end that appear to block the flow of barium from the interior. In addition, a numerical model of barium transport in the insert plasma indicates that the barium partial pressure in the insert may exceed the equilibrium vapor pressure of the dominant barium-producing reaction, and it was postulated previously that this would suppress barium loss in the upstream part of the insert. New measurements of the depth of barium depletion from a cathode insert operated for 30,352 hours reveal that barium loss is confined to a narrow region near the downstream end, confirming this hypothesis.

  4. Assessment of radiation doses due to normal operation, incidents and accidents of the final disposal facility; Kaeytetyn ydinpolttoaineen loppusijoituslaitoksen normaalikaeytoen, kaeyttoehaeirioeiden ja onnettomuustilanteiden aiheuttamien saeteilyannosten arviointi

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, J.; Raiko, H.; Suolanen, V.; Ilvonen, M. [VTT Energy, Espoo (Finland)

    1999-03-01

    Radiation doses for workers of the encapsulation and disposal facility and for inhabitants in the environment caused by the facility during its operation were considered. The study covers both the normal operation of the plant and some hypothetical incidents and accidents. Occupational radiation doses inside the plant during normal operation are based on the design basis, assuming that highest permitted dose levels are prevailing in control rooms during fuel transfer and encapsulation processes. Release through the ventilation stack is assumed to be filtered both in normal operation and in hypothetical incident and accident cases. Calculation of the offsite doses from normal operation is based on the hypothesis that one fuel pin per 100 fuel bundles for all batches of spent fuel transported to the encapsulation facility is leaking. The release magnitude in incidents and accidents is based on the event chains, which lead to loss of fuel pin tightness followed by a discharge of radionuclides into the handling chamber and to some degree through the ventilation stack into atmosphere. The weather data measured at the Olkiluoto meteorological mast was employed for calculating of offsite doses. Therefore doses could be calculated in a large amount of different dispersion conditions, the statistical frequencies of which have, been measured. Finally doses were combined into cumulative distributions, from which a dose value representing the 99.5 % confidence level, is presented. The dose values represent the exposure of a critical group, which is assumed to live at the distance of 200 meters from the encapsulation and disposal plant and thus it will receive the largest doses in most dispersion conditions. Exposure pathways considered were: cloudsnine, inhalation, groundshine and nutrition (milk of cow, meat of cow, green vegetables, grain and root vegetables). Nordic seasonal variation is included in ingestion dose models. The results obtained indicate that offsite doses

  5. Normal ordering expansion of n-dimensional radial coordinate operators gained by virtue of the IWOP technique

    CERN Document Server

    Fan Hong Yi

    2003-01-01

    By virtue of the technique of integration within an ordered product of operators we derive the normal ordering expansion of the power of radial coordinate operators in the n-dimensional coordinate space. The use of Bessel function has greatly simplified the calculation. Moreover, the use of Kummer's first formula for the confluent hypergeometric function makes the result neat and concise. (addendum)

  6. Percutaneous transhepatic biliary drainage through the normal duct in patients with post-operative bile leakage

    International Nuclear Information System (INIS)

    Lee, Hyun; Kim, Young Hwan; Kim, Yong Joo

    2004-01-01

    To evaluate the technical feasibility and clinical efficacy of percutaneous transhepatic biliary drainage (PTBD) through the normal duct in patients with post-operative bile leakage. From January 1998 to December 2003, fourteen patients (male: 12, female: 2, mean age: 56) with biliary leak after laparoscopic cholecystectomy (n = 5), T-tube removal (n = 5), choledochojejunostomy due to small bowel perforation (n = 1), right lobectomy (n = 1), laparoscopic adrenalectomy (n = 1), and subtotal gastrectomy (n = 1) were treated by means of PTBD; this was performed with the two-step approach. The central bile duct was cannulated using a 21-G Chiba needle to map the intrahepatic biliary tree. An 8.5-F drainage catheter tip was positioned at the CBD after puncturing peripheral bile duct with an additional Chiba needle. We evaluated the technical feasibility, the procedure-related complications, clinical efficacy and the duration of catheter placement. PTBD of the normal duct with the two-step approach was successful in all but two cases. In these two cases, the two-step approach was failed due to the rapid disappearance of the targeted peripheral duct, and this was the result caused by biloportal fistula. PTBD was performed through the central bile duct in one patient, and through the remnant cystic duct in one patient. There were no procedure-related complications except for mild abdominal pain in seven patients. Bile leakage was demonstrated on cholangiogram in 10 of 14 patients; this occurred at the T-tube exit site (n = 4), cystic duct stump (n = 2), choledochojejunostomy site (n = 1), resection margin of liver (n = 1), caudate lobe (n = 1), and GB bed (n = 1). In 13 patients, the biliary leak stopped after drainage (mean duration: 32.1 days). In one patient, surgical management was performed one day after PTBD due to the excessive amount of bile leakage. PTBD is a technically feasible and clinically efficacious treatment for post-operative bile leakage, and it can

  7. Worst-case prediction of normal operating containment temperatures for environmentally qualified equipment

    International Nuclear Information System (INIS)

    Krasnopoler, M.J.; Sundergill, J.E.

    1991-01-01

    Due to issues raised in NRC Information Notice No. 87-65, a southern US nuclear plant was concerned about thermal aging of environmentally qualified (EQ) equipment located in areas of elevated containment temperatures. A method to predict the worst-case monthly temperatures at various zones in the containment and calculate the qualified life using this monthly temperature was developed. Temperatures were predicted for twenty locations inside the containment. Concern about the qualified life of EQ equipment resulted from normal operating temperatures above 120F in several areas of the containment, especially during the summer. At a few locations, the temperature exceeded 140F. Also, NRC Information Notice No. 89-30 reported high containment temperatures at three other nuclear power plants. The predicted temperatures were based on a one-year containment temperature monitoring program. The monitors included permanent temperature monitors required by the Technical Specifications and temporary monitors installed specifically for this program. The temporary monitors were installed near EQ equipment in the expected worst-case areas based on design and operating experience. A semi-empirical model that combined physical and statistical models was developed. The physical model was an overall energy balance for the containment. The statistical model consists of several linear regressions that conservatively relate the monitor temperatures to the bulk containment temperature. The resulting semi-empirical model predicts the worst-case monthly service temperatures at the location of each of the containment temperature monitors. The monthly temperatures are the maximum expected because they are based on the historically worst-case atmospheric data

  8. Laboratory determination of normal operating flow rates with enlarged outlet fittings -- BDF reactors

    Energy Technology Data Exchange (ETDEWEB)

    Waters, E.D.

    1960-02-02

    Experiments have been conducted in the Hydraulics Laboratory, at the request of IPD`s Mechanical Development-A Operation, to determine the energy losses of various enlarged outlet fitting combinations. These experiments were conducted an steady state runs and allow the determination of the normal operating point (flow rate) of a reactor process channel under selected conditions of front header pressure and fuel charge. No attempt is made to make a mechanical or economic evaluation of the particular fitting combinations, although observations were noted which might bear on this evaluation. It is very important for the reader to bear in mind that changing outlet fittings will definitely affect the reactor tube power limits and outlet vater temperature limits. The size of the outlet fittings largely determines the present outlet temperature limits of the old reactors. The flow characteristics of these present fittings cause some degree of pressurization to suppress boiling on the fuel charge and also cause dual Panellit trip protection for certain flow changes and for power surges. Enlargement of the outlet fittings may actually reduce the allowable outlet coolant temperature limits. Since these effects cannot be determined on the apparatus used in these experiments, a complete discussion of this point is not included in this report. However, the seriousness of these effects should be known and carefully analyzed before a final selection of enlarged outlet fittings in made. This report will be one of a series. New reports in the series will be issued as data are obtained for other such outlet fitting combinations or for new concepts of outlet fitting assemblies such as the new nozzle being developed by C. E. Trantz for use on F-reactor stuck gunbarrel tubes.

  9. Neutronics and Fuel Performance Evaluation of Accident Tolerant Fuel under Normal Operation Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Xu Wu; Piyush Sabharwall; Jason Hales

    2014-07-01

    This report details the analysis of neutronics and fuel performance analysis for enhanced accident tolerance fuel, with Monte Carlo reactor physics code Serpent and INL’s fuel performance code BISON, respectively. The purpose is to evaluate two of the most promising candidate materials, FeCrAl and Silicon Carbide (SiC), as the fuel cladding under normal operating conditions. Substantial neutron penalty is identified when FeCrAl is used as monolithic cladding for current oxide fuel. From the reactor physics standpoint, application of the FeCrAl alloy as coating layer on surface of zircaloy cladding is possible without increasing fuel enrichment. Meanwhile, SiC brings extra reactivity and the neutron penalty is of no concern. Application of either FeCrAl or SiC could be favorable from the fuel performance standpoint. Detailed comparison between monolithic cladding and hybrid cladding (cladding + coating) is discussed. Hybrid cladding is more practical based on the economics evaluation during the transition from current UO2/zircaloy to Accident Tolerant Fuel (ATF) system. However, a few issues remain to be resolved, such as the creep behavior of FeCrAl, coating spallation, inter diffusion with zirconium, etc. For SiC, its high thermal conductivity, excellent creep resistance, low thermal neutron absorption cross section, irradiation stability (minimal swelling) make it an excellent candidate materials for future nuclear fuel/cladding system.

  10. FREC-4A: a computer program to predict fuel rod performance under normal reactor operation

    International Nuclear Information System (INIS)

    Harayama, Yasuo; Izumi, Fumio

    1981-10-01

    The program FREC-4A (Fuel Reliability Evaluation Code-version 4A) is used for predicting fuel rod performance in normal reactor operation. The performance is calculated in accordance with the irradiation history of fuel rods. Emphasis is placed on the prediction of the axial elongation of claddings induced by pellet-cladding mechanical interaction, including the influence of initially preloaded springs inserted in fuel rod lower plenums. In the FREC-4A, an fuel rod is divided into axial segments. In each segment, it is assumed that the temperature, stress and strain are axi-symmetrical, and the axial strain in constant in fuel pellets and in a cladding, though the values in the pellets and in the cladding are different. The calculation of the contact load and the clearance along the length of a fuel rod and the stress and strain in each segment is explained. The method adopted in the FREC-4A is simple, and suitable to predict the deformation of fuel rods over their full length. This report is described on the outline of the program, the method of solving the stiffness equations, the calculation models, the input data such as irradiation history, output distribution, material properties and pores, the printing-out of input data and calculated results. (Kako, I.)

  11. ''Meteor 2'' programme for calculation of environment irradiation under nuclear power plant normal operating conditions

    International Nuclear Information System (INIS)

    Oppermann, R.; Kryuger, F.V.; Prior, Kh.

    1976-01-01

    A ''Meteor 2'' program developed for the BESM-6 electronic computer is described. The program permits to estimate radiation effect under nuclear power plant normal operation conditions. The calculations are carried out depending on the quantity and composition of the release activity, a ventilating pipe height, meteorological conditions as well as taking into account radioactive substance decay. The program permits to calculate the following values in the vicinity of radioactive product release point: a local distribution of a mean dose spread factor; a local distribution of a mean dose of inhalation irradiation for various human organs (the whole body, thyroid gland, bones, alimentary canal, lungs) and separate population groups; a local distribution of a mean dose of external beta radiation; a local distribution of a mean dose of external gamma radiation. The program includes the main ''Meteor'' program and 3 subprograms of DOBER, DABER and DABOR and is written in the FORTRAN language. The ''Meteor'' program organizes the data input and output of some separate subprograms. The DOBER subprogram determines the spread factor, the inhalation irradiation dose for separate organs and the external beta radiation dose. The DABER subprogram determines the external gamma radiation dose in the approximation of homogeneous distribution of a source in the vicinity of the calculation point. The DABOR subprogram is the second program for the calculating the external irradiation dose. The examples of using the ''Meteor'' program are given [ru

  12. DOSEFU: Computer application for dose calculation and effluent management in normal operation

    International Nuclear Information System (INIS)

    Martin Garcia, J. E.; Gonzalvo Manovel, A.; Revuelta Garcia, L.

    2002-01-01

    DOSEFU is a computer application on Windows that develops the methodology of nuclear power plant Exterior Dose Calculation Manuals (Manuals de Calculo de Dosis al Exterior-MACADE) for calculating doses in normal operation caused by radioactive liquid and gaseous effluents, for the purpose of enforcing the new Spanish Regulation on Health Protection against Ionizing Radiations, Royal Decree 783/2001 resulting from transposition of Directive 96/29/Euratom whereby the basic rules regarding health protection of workers and the population against risks resulting from ionizing radiations are established. In addition to making dose calculations, DOSEFU generates, on a magnetic support, the information regarding radioactive liquid and gaseous effluents that plants must periodically send to the CSN (ELGA format). The computer application has been developed for the specific case of Jose Cabrera NPP, which is called DOEZOR. This application can be easily implemented in any other nuclear or radioactive facility. The application is user-friendly, as the end user inputs data and executes the different modules through keys and dialogue boxes that are enabled by clicking on the mouse (see figures 2, 3, 4 and 5 ), The application runs under Windows 95. Digital Visual Fortran has been used as the development program, as this does not require additional libraries (DLLs), it can be installed in any computer without affecting other programs that are already installed. (Author)

  13. Evaluation of gap heat transfer model in ELESTRES for CANDU fuel element under normal operating conditions

    International Nuclear Information System (INIS)

    Lee, Kang Moon; Ohn, Myung Ryong; Im, Hong Sik; Choi, Jong Hoh; Hwang, Soon Taek

    1995-01-01

    The gap conductance between the fuel and the sheath depends strongly on the gap width and has a significant influence on the amount of initial stored energy. The modified Ross and Stoute gap conductance model in ELESTRES is based on a simplified thermal deformation model for steady-state fuel temperature calculations. A review on a series of experiments reveals that fuel pellets crack, relocate, and are eccentrically positioned within the sheath rather than solid concentric cylinders. In this paper, the two recently-proposed gap conductance models (offset gap model and relocated gap model) are described and are applied to calculate the fuel-sheath gap conductances under experimental conditions and normal operating conditions in CANDU reactors. The good agreement between the experimentally-inferred and calculated gap conductance values demonstrates that the modified Ross and Stoute model was implemented correctly in ELESTRES. The predictions of the modified Ross and Stoute model provide conservative values for gap heat transfer and fuel surface temperature compared to the offset gap and relocated gap models for a limiting power envelope. 13 figs., 3 tabs., 16 refs. (Author)

  14. Dose conversion factors for radiation doses at normal operation discharges. F. Methods report; Dosomraekningsfaktorer foer normaldriftutslaepp. F. Metodrapport

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Ulla; Hallberg, Bengt; Karlsson, Sara

    2001-10-01

    A study has been performed in order to develop and extend existing models for dose estimations at emissions of radioactive substances from nuclear facilities in Sweden. This report gives a review of the different exposure pathways that have been considered in the study. Radioecological data that should be used in calculations of radiation doses are based on the actual situation at the nuclear sites. Dose factors for children have been split in different age groups. The exposure pathways have been carefully re-examined, like the radioecological data; leading to some new pathways (e.g. doses from consumption of forest berries, mushrooms and game) for cesium and strontium. Carbon 14 was given a special treatment by using a model for uptake of carbon by growing plants. For exposure from aquatic emissions, a simplification was done by focussing on the territory for fish species, since consumption of fish is the most important pathway.

  15. Closure report for CAU 339: Area 12 Fleet Operations steam-cleaning discharge area, Nevada Test Site

    International Nuclear Information System (INIS)

    1997-12-01

    This Closure Report (CR) provides documentation of the completed corrective action at the Area 12 Fleet Operations site located in the southeast portion of the Area 12 Camp at the Nevada Test Site (NTS). Field work was performed in July 1997 as outlined in the Corrective Action Plan (CAP). The CAP was approved by the Nevada Division of Environmental Protection (NDEP) in June 1997. This site is identified in the Federal Facility Agreement and Consent Order (FFACO) as Corrective Action Site (CAS) Number 12-19-01 and is the only CAS in Corrective Action Unit (CAU) 339. The former Area 12 Fleet Operations Building 12-16 functioned as a maintenance facility for light- and heavy-duty vehicles from approximately 1965 to January 1993. Services performed at the site included steam-cleaning, tire service, and preventative maintenance on vehicles and equipment. Past activities impacted the former steam-cleaning discharge area with volatile organic compounds (VOCs) and total petroleum hydrocarbons (TPH) as oil

  16. Kinetic model of a Ne-H2 Penning Recombination Laser operating in the hollow cathode discharge

    International Nuclear Information System (INIS)

    Pramatarov, P.M.; Stefanova, M.S.; Petrov, G.M.

    1995-01-01

    The Penning Recombination Laser (PRL) requires the presence of both a recombination plasma populating the upper laser level (ULL) and a gas component efficiently depopulating the lower laser level (LLL) by Penning reactions. Such requirements are met in the negative glow plasma of a pulsed high voltage Ne-H 2 discharge with a helical hollow cathode. High rates of ionizations followed by recombinations are reached due to the beam component of non-Maxwellian electrons of 1-2 keV energy present in the tail of the electron energy distribution function. The H 2 , on the one hand plays the role of Penning component and on the other hand effectively cools the electrons by rotational and vibrational levels excitation. The latter contributes to the effectiveness of the recombination processes. A kinetic model of the physical processes determining the inversion population on the NeI(2p 1 -1s 2 ) transition (the 585.3 nm line) in a Ne-H 2 PRL operating in a high voltage hollow cathode discharge at intermediate pressures is proposed. About 60 plasma-chemical reactions are considered in the model. These include: two-electron recombination of Ne + ; dissociative recombination of Ne 2 + , NeH + and H 2 + ; ion-ion recombination of Ne + and H - ; Ne and H 2 direct ionization by fast electrons; Ne stepwise ionization; Penning ionization; Ne excitation by fast electrons; Ne stepwise excitation and de-excitation; radiative transitions; electron mixing between Ne excited states; H 2 rotational and vibrational levels excitation; H 2 dissociative attachment; elastic electron collisions with H 2 and Ne. The rate constants for the reactions are either taken from the literature or calculated in this work

  17. Normal Operating Range of Bacterial Communities in Soil Used for Potato Cropping

    Science.gov (United States)

    İnceoğlu, Özgül; van Overbeek, Leo Simon; Falcão Salles, Joana

    2013-01-01

    In this study, the impacts of six potato (Solanum tuberosum) cultivars with different tuber starch allocations (including one genetically modified [GM] line) on the bacterial communities in field soil were investigated across two growth seasons interspersed with 1 year of barley cultivation, using quantitative PCR, clone library, and PCR-denaturing gradient gel electrophoresis (DGGE) analyses. It was hypothesized that the modifications in the tuber starch contents of these plants, yielding changed root growth rates and exudation patterns, might have elicited altered bacterial communities in the soil. The data showed that bacterial abundances in the bulk soil varied over about 2 orders of magnitude across the 3 years. As expected, across all cultivars, positive potato rhizosphere effects on bacterial abundances were noted in the two potato years. The bulk soil bacterial community structures revealed progressive shifts across time, and moving-window analysis revealed a 60% change over the total experiment. Consistent with previous findings, the community structures in the potato rhizosphere compartments were mainly affected by the growth stage of the plants and, to a lesser extent, by plant cultivar type. The data from the soil under the non-GM potato lines were then taken to define the normal operating range (NOR) of the microbiota under potatoes. Interestingly, the bacterial communities under the GM potato line remained within this NOR. In regard to the bacterial community compositions, particular bacterial species in the soil appeared to be specific to (i) the plant species under investigation (barley versus potato) or, with respect to potatoes, (ii) the plant growth stage. Members of the genera Arthrobacter, Streptomyces, Rhodanobacter, and Dokdonella were consistently found only at the flowering potato plants in both seasons, whereas Rhodoplanes and Sporosarcina were observed only in the soil planted to barley. PMID:23220956

  18. Axial mercury segregation in direct current operated low-pressure argon-mercury gas discharges: Part I. Experimental

    International Nuclear Information System (INIS)

    Gielen, John W A M; Groot, Simon de; Mullen, Joost J A M van der

    2004-01-01

    Due to cataphoresis, axial segregation of mercury will occur when the gas discharge of a fluorescent lamp is operated by means of a direct current. A consequence of this is a non-uniform axial luminance distribution along the lamp. To determine the degree of axial mercury segregation experimentally, axial luminance distributions have been measured which are converted into axial mercury vapour pressure distributions by an appropriate calibration method. The mercury segregation has been investigated for variations in lamp tube radius (3.6-4.8 mm), argon buffer gas pressure (200-600 Pa) and lamp current (100-250 mA) at mercury vapour pressures set at the anode in the range from 0.2 to 9.0 Pa. From the experiments it has been concluded that the mercury vapour pressure gradient at any axial position for a certain lamp tube diameter, argon pressure and lamp current depends on the local mercury vapour pressure. This observation is in contrast to assumptions made in earlier modelling publications in which one mercury vapour pressure gradient is used for all axial positions. By applying a full factorial design, an empirical relation of the mercury segregation is found for any set of parameters inside the investigated parameter ranges

  19. On the physical processes ruling an atmospheric pressure air glow discharge operating in an intermediate current regime

    Energy Technology Data Exchange (ETDEWEB)

    Prevosto, L., E-mail: prevosto@waycom.com.ar; Mancinelli, B.; Chamorro, J. C.; Cejas, E. [Grupo de Descargas Eléctricas, Departamento Ing. Electromecánica, Facultad Regional Venado Tuerto (UTN), Laprida 651, Venado Tuerto (2600), Santa Fe (Argentina); Kelly, H. [Grupo de Descargas Eléctricas, Departamento Ing. Electromecánica, Facultad Regional Venado Tuerto (UTN), Laprida 651, Venado Tuerto (2600), Santa Fe (Argentina); Instituto de Física del Plasma (CONICET), Facultad de Ciencias Exactas y Naturales (UBA) Ciudad Universitaria Pab. I, 1428, Buenos Aires (Argentina)

    2015-02-15

    Low-frequency (100 Hz), intermediate-current (50 to 200 mA) glow discharges were experimentally investigated in atmospheric pressure air between blunt copper electrodes. Voltage–current characteristics and images of the discharge for different inter-electrode distances are reported. A cathode-fall voltage close to 360 V and a current density at the cathode surface of about 11 A/cm{sup 2}, both independent of the discharge current, were found. The visible emissive structure of the discharge resembles to that of a typical low-pressure glow, thus suggesting a glow-like electric field distribution in the discharge. A kinetic model for the discharge ionization processes is also presented with the aim of identifying the main physical processes ruling the discharge behavior. The numerical results indicate the presence of a non-equilibrium plasma with rather high gas temperature (above 4000 K) leading to the production of components such as NO, O, and N which are usually absent in low-current glows. Hence, the ionization by electron-impact is replaced by associative ionization, which is independent of the reduced electric field. This leads to a negative current-voltage characteristic curve, in spite of the glow-like features of the discharge. On the other hand, several estimations show that the discharge seems to be stabilized by heat conduction; being thermally stable due to its reduced size. All the quoted results indicate that although this discharge regime might be considered to be close to an arc, it is still a glow discharge as demonstrated by its overall properties, supported also by the presence of thermal non-equilibrium.

  20. Normal ordering expansion of n-dimensional radial coordinate operators gained by virtue of the IWOP technique

    Energy Technology Data Exchange (ETDEWEB)

    Fan Hongyi [CCAST (World Laboratory), PO Box 8730, Beijing (China); Fu Liang [Special Class of Gifted Young, University of Science and Technology of China, Hefei, Anhui (China)

    2003-02-07

    By virtue of the technique of integration within an ordered product of operators we derive the normal ordering expansion of the power of radial coordinate operators in the n-dimensional coordinate space. The use of Bessel function has greatly simplified the calculation. Moreover, the use of Kummer's first formula for the confluent hypergeometric function makes the result neat and concise. (addendum)

  1. Figurative and Operative Bases of Memory: Evidence from Normal and Learning Disabled Child.

    Science.gov (United States)

    Trepanier, Mary L.; Liben, Lynn S.

    A set of studies investigated the relative importance of operative schemes and figurative (rote) memory. In Study I, 60 concrete operational children from grades 1-4 were asked to reconstruct two types of stimuli from memory. In order to separate the effects of operative and figurative skill use, learning disabled children with poor figurative…

  2. A computerized operator support system for BWR power plant during normal and abnormal conditions

    International Nuclear Information System (INIS)

    Monta, K.; Sato, N.; Tsunoyama, S.; Sekimizu, K.; Mori, N.

    1984-01-01

    A computerized operator support system for BWR was developed based on the operators tasks which are divided into problem solving and controlling. Problem solving comprises fault managing and planning tasks. One of the operator supports for the problem solving is the automatic diagnostic support. However, the operator supports for controlling tasks are still important, e.g. to support its rule memory and rule execution. In the system presented here, operator supports are considered for both of these two categories. In the paper two subsystems for the latter are mainly described. (author)

  3. Supporting inland waterway transport on German waterways by operational forecasting services - water-levels, discharges, river ice

    Science.gov (United States)

    Meißner, Dennis; Klein, Bastian; Ionita, Monica; Hemri, Stephan; Rademacher, Silke

    2017-04-01

    Inland waterway transport (IWT) is an important commercial sector significantly vulnerable to hydrological impacts. River ice and floods limit the availability of the waterway network and may cause considerable damages to waterway infrastructure. Low flows significantly affect IWT's operation efficiency usually several months a year due to the close correlation of (low) water levels / water depths and (high) transport costs. Therefore "navigation-related" hydrological forecasts focussing on the specific requirements of water-bound transport (relevant forecast locations, target parameters, skill characteristics etc.) play a major role in order to mitigate IWT's vulnerability to hydro-meteorological impacts. In light of continuing transport growth within the European Union, hydrological forecasts for the waterways are essential to stimulate the use of the free capacity IWT still offers more consequently. An overview of the current operational and pre-operational forecasting systems for the German waterways predicting water levels, discharges and river ice thickness on various time-scales will be presented. While short-term (deterministic) forecasts have a long tradition in navigation-related forecasting, (probabilistic) forecasting services offering extended lead-times are not yet well-established and are still subject to current research and development activities (e.g. within the EU-projects EUPORIAS and IMPREX). The focus is on improving technical aspects as well as on exploring adequate ways of disseminating and communicating probabilistic forecast information. For the German stretch of the River Rhine, one of the most frequented inland waterways worldwide, the existing deterministic forecast scheme has been extended by ensemble forecasts combined with statistical post-processing modules applying EMOS (Ensemble Model Output Statistics) and ECC (Ensemble Copula Coupling) in order to generate water level predictions up to 10 days and to estimate its predictive

  4. Heart pacemaker - discharge

    Science.gov (United States)

    Cardiac pacemaker implantation - discharge; Artificial pacemaker - discharge; Permanent pacemaker - discharge; Internal pacemaker - discharge; Cardiac resynchronization therapy - discharge; CRT - discharge; ...

  5. Impact of changed fuel performances on safety barrier effectiveness at normal operation of NPP with WWER

    International Nuclear Information System (INIS)

    Zhurbenko, A. V.; Semchenkov, Y. M.; Slavyagin, P.D.

    2007-01-01

    The paper presents the analysis of adopted safety barriers against propagation of fission product released from WWER core of active power plants. Relationship between system and equipment performances and safety barriers is demonstrated. The fundamental principles of methodological approach to the operational limit determination based on the assessment of iodine-131 specific activity in the primary circuit are discussed. Problems of substantiating the operational limit for primary coolant activity are analyzed for conditions of growing burnup (Authors)

  6. Cooling system of the core of a nuclear reactor while it is being stopped or normally operating

    International Nuclear Information System (INIS)

    Tilliette, Z.

    1986-01-01

    The present invention proposes a cooling system with intermediate gas flow which ensures the reactor core cooling when the primary pumps are stopped either directly by means of main heat-exchange circuits ensuring normally the reactor operation, or by means of separated loops, these ones being able so to operate in an autonomous way for they produce their own electricity needs and also an excedent which is added to the power plant production. The cooling circuit and the heat exchanger are described in detail [fr

  7. Distributed hierarchical control architecture for integrating smart grid assets during normal and disrupted operations

    Science.gov (United States)

    Kalsi, Karan; Fuller, Jason C.; Somani, Abhishek; Pratt, Robert G.; Chassin, David P.; Hammerstrom, Donald J.

    2017-09-12

    Disclosed herein are representative embodiments of methods, apparatus, and systems for facilitating operation and control of a resource distribution system (such as a power grid). Among the disclosed embodiments is a distributed hierarchical control architecture (DHCA) that enables smart grid assets to effectively contribute to grid operations in a controllable manner, while helping to ensure system stability and equitably rewarding their contribution. Embodiments of the disclosed architecture can help unify the dispatch of these resources to provide both market-based and balancing services.

  8. Simulation of zincblende AlGaN/GaN high electron mobility transistors for normally-off operation

    Science.gov (United States)

    Grady, R.; Bayram, C.

    2017-07-01

    In this work we investigate design parameters enabling normally-off operation of zincblende (ZB-) phase Al X Ga(1-X)N/GaN high electron mobility transistors (HEMTs) via Synopsys Sentaurus Technology Computer Aided Design (TCAD). As ZB-phase III-nitrides are polarization-free, the 2D electron gas (2DEG) channel at the Al X Ga(1-X)N/GaN heterojunction is formed through intentional δ-doping part of the Al X Ga(1-X)N barrier layer. The impact of each of the design parameters (i.e. Al-content and thickness of Al X Ga(1-X)N barrier; δ-doping location (within the Al X Ga(1-X)N barrier), δ-doped Al X Ga(1-X)N layer thickness and its doping amount; gate metal) are studied in detail and design trade-offs are reported. We show that work function of the gate metal impacts normally-off behavior and turn-on voltage considerably. Our results suggest that Al-content of 35% or less in the Al X Ga(1-X)N barrier results in a normally-off behavior whereas Al X Ga(1-X)N barrier thickness is effective in controlling the turn-on voltage. Overall, we provide design guidelines in controlling the normally-on/-off operation, threshold voltage, and 2DEG density in ZB-phase AlGaN/GaN HEMT technology.

  9. Identifying discharge practice training needs.

    Science.gov (United States)

    Lees, L; Emmerson, K

    A training needs analysis tool was developed to identify nurses' discharge training needs and to improve discharge practice. The tool includes 49 elements of discharge practice subdivided into four areas: corporate, operational, clinical and nurse-led discharge. The tool was disseminated to 15 wards on two hospital sites with assistance from the practice development team. Analysis of discharge training is important to assess discharge training needs and to identify staff who may assist with training.

  10. Versatile Oxide Films Protect FeCrAl Alloys Under Normal Operation and Accident Conditions in Light Water Power Reactors

    Science.gov (United States)

    Rebak, Raul B.

    2018-02-01

    The US has currently a fleet of 99 nuclear power light water reactors which generate approximately 20% of the electricity consumed in the country. Near 90% of the reactors are at least 30 years old. There are incentives to make the existing reactors safer by using accident tolerant fuels (ATF). Compared to the standard UO2-zirconium-based system, ATF need to tolerate loss of active cooling in the core for a considerably longer time while maintaining or improving the fuel performance during normal operation conditions. Ferritic iron-chromium-aluminum (FeCrAl) alloys have been identified as an alternative to replace current zirconium alloys. They contain Fe (base) + 10-22 Cr + 4-6 Al and may contain smaller amounts of other elements such as molybdenum and traces of others. FeCrAl alloys offer outstanding resistance to attack by superheated steam by developing an alumina oxide on the surface in case of a loss of coolant accident like at Fukushima. FeCrAl alloys also perform well under normal operation conditions both in boiling water reactors and pressurized water reactors because they are protected by a thin oxide rich in chromium. Under normal operation condition, the key element is Cr and under accident conditions it is Al.

  11. The effect of UV treatment on highly polluted and normal operated swimming pools

    DEFF Research Database (Denmark)

    Spiliotopoulou, Aikaterini; Kaarsholm, Kamilla Marie Speht; Andersen, Henrik Rasmus

    2017-01-01

    “It should be light blue, transparent” (Mario Andrada, speakerman, Olympic Games, Rio, 2016) was the comment for the “green lake”. Swimming pools are sensitive recirculating systems. A malfunction in water treatment units or a poor operating decision could possibly lead to health-endangering or a...

  12. Energy efficiency estimation of a steam powered LNG tanker using normal operating data

    Directory of Open Access Journals (Sweden)

    Sinha Rajendra Prasad

    2016-01-01

    Full Text Available A ship’s energy efficiency performance is generally estimated by conducting special sea trials of few hours under very controlled environmental conditions of calm sea, standard draft and optimum trim. This indicator is then used as the benchmark for future reference of the ship’s Energy Efficiency Performance (EEP. In practice, however, for greater part of operating life the ship operates in conditions which are far removed from original sea trial conditions and therefore comparing energy performance with benchmark performance indicator is not truly valid. In such situations a higher fuel consumption reading from the ship fuel meter may not be a true indicator of poor machinery performance or dirty underwater hull. Most likely, the reasons for higher fuel consumption may lie in factors other than the condition of hull and machinery, such as head wind, current, low load operations or incorrect trim [1]. Thus a better and more accurate approach to determine energy efficiency of the ship attributable only to main machinery and underwater hull condition will be to filter out the influence of all spurious and non-standard operating conditions from the ship’s fuel consumption [2]. The author in this paper identifies parameters of a suitable filter to be used on the daily report data of a typical LNG tanker of 33000 kW shaft power to remove effects of spurious and non-standard ship operations on its fuel consumption. The filtered daily report data has been then used to estimate actual fuel efficiency of the ship and compared with the sea trials benchmark performance. Results obtained using data filter show closer agreement with the benchmark EEP than obtained from the monthly mini trials . The data filtering method proposed in this paper has the advantage of using the actual operational data of the ship and thus saving cost of conducting special sea trials to estimate ship EEP. The agreement between estimated results and special sea trials EEP is

  13. Computer simulation of WWER - 440 normal and emergency transient operating conditions

    International Nuclear Information System (INIS)

    Izbeshesku, M.; Rajka, V.; Untaru, S.; Dumitresku, A.; Paneh, M.; Turku, I.

    1976-01-01

    Results of computer realization of a model for studying transient process in the nuclear system of vapour production at the WWER - 40 peactor nuclear power plant are presented. The first circuit model consists of a number of modules, corresponding to its main parts: for each module derived were the equations describing neutron and thermohydraulic parameters. The second circuit effect is taken into account by heat quantity accepted from a steam generator. The equations are mostly differential with constant coefficients. Coefficient values and initial values of physical quantities are evaluated according to the technical literature. Both manual and automatic operations are modelled [ru

  14. Probabilistic analysis in normal operation of distribution system with distributed generation

    DEFF Research Database (Denmark)

    Villafafila-Robles, R.; Sumper, A.; Bak-Jensen, B.

    2011-01-01

    Nowadays, the incorporation of high levels of small-scale non-dispatchable distributed generation is leading to the transition from the traditional 'vertical' power system structure to a 'horizontally-operated' power system, where the distribution networks contain both stochastic generation...... and load. This fact increases the number of stochastic inputs and dependence structures between them need to be considered. The deterministic analysis is not enough to cope with these issues and a new approach is needed. Probabilistic analysis provides a better approach. Moreover, as distribution systems...... consist of a small areas, the dependence between stochastic inputs should be considered. In this paper, probabilistic analysis based on Monte Carlo simulation is described and applied to a real system....

  15. Pragmatic approach to chest pain patients discharged with undetectable high-sensitivity troponin T and normal electrocardiogram: the STABS + CT protocol.

    Science.gov (United States)

    Bishop, Warrick; Girao, Gary

    2017-06-01

    A strategy that discharges chest pain patients with negative high-sensitivity troponin and non-ischaemic electrocardiography changes may still result in 0.44% of patients experiencing myocardial infarction within 30 days. We observed that a pragmatic approach that systematically discharged 25 patients on cardio-protective medications of aspirin, metoprolol and atorvastatin followed with prompt (<10 days) coronary computed tomography angiography resulted in no major adverse cardiac event and adverse drug reaction 30 days post-presentation. The strategy resulted in three patients (12%) ultimately diagnosed with likely unstable angina, which required planned coronary intervention in two patients and medical management in one patient. No unplanned readmissions for chest pains were noted from initial presentation through to 6-month follow up. © 2017 Royal Australasian College of Physicians.

  16. New layout concepts in MW-scale IGBT modules for higher robustness during normal and abnormal operations

    DEFF Research Database (Denmark)

    Reigosa, Paula Diaz; Iannuzzo, Francesco; Munk-Nielsen, Stig

    2016-01-01

    This paper presents six different layout designs for MW-level Insulated-Gate Bipolar Transistor (IGBT) modules. The aim is to optimize the normal switching and abnormal short circuit performances of IGBT modules in terms of stray inductance reduction and inductance coupling cancellation. Using...... the Finite-Element-Method AnSYS Q3D Extractor, electromagnetic simulations are conducted to extract the self and mutual inductance from the six different layouts. PSpice simulations are used to reveal that the stray parameters inside the module play an important role under normal and abnormal operations......, and thus the best performing layout strategies can be selected. The prototypes are fabricated to validate the results of the Q3D simulation analysis, in which the self-inductance is measured by using a high precision impedance analyzer....

  17. The ladder operator normal ordering problem for quantum confined systems and the generalization of the Stirling and Bell numbers

    International Nuclear Information System (INIS)

    Aleixo, A N F; Balantekin, A B

    2010-01-01

    We solve the normal ordering problem for the ladder operators B-hat + and B-hat - for strings in the form (B-hat + r B-hat - s ) n for supersymmetric and shape-invariant potential systems, with r, s and n positive integers. We provide exact and explicit expressions for their normal form N{(B-hat + r B-hat - s ) n }, where N{...} all B-hat - are at the right side, and find that the solution involves an expansion coefficients sequence which, for r, s > 1, corresponds to the generalization, for any shape-invariant potential system, of the classical Stirling and Bell numbers. We show that these numbers are obtained for families of polynomials generated with parameters related to the forms of the supersymmetric partner potentials. We apply the general formalism to Poeschl-Teller, Morse, Scarf and self-similar potential systems.

  18. Simulation of zincblende AlGaN/GaN high electron mobility transistors for normally-off operation

    International Nuclear Information System (INIS)

    Grady, R; Bayram, C

    2017-01-01

    In this work we investigate design parameters enabling normally-off operation of zincblende (ZB-) phase Al X Ga (1−X) N/GaN high electron mobility transistors (HEMTs) via Synopsys Sentaurus Technology Computer Aided Design (TCAD). As ZB-phase III-nitrides are polarization-free, the 2D electron gas (2DEG) channel at the Al X Ga (1−X) N/GaN heterojunction is formed through intentional δ -doping part of the Al X Ga (1−X) N barrier layer. The impact of each of the design parameters (i.e. Al-content and thickness of Al X Ga (1−X) N barrier; δ -doping location (within the Al X Ga (1−X) N barrier), δ-doped Al X Ga (1−X) N layer thickness and its doping amount; gate metal) are studied in detail and design trade-offs are reported. We show that work function of the gate metal impacts normally-off behavior and turn-on voltage considerably. Our results suggest that Al-content of 35% or less in the Al X Ga (1−X) N barrier results in a normally-off behavior whereas Al X Ga (1−X) N barrier thickness is effective in controlling the turn-on voltage. Overall, we provide design guidelines in controlling the normally-on/-off operation, threshold voltage, and 2DEG density in ZB-phase AlGaN/GaN HEMT technology. (paper)

  19. Control of the electrical operating point of an electric discharge by mean of its power supply; Controle du point de fonctionnement des decharges electriques par l'intermediaire de leur alimentation

    Energy Technology Data Exchange (ETDEWEB)

    Salanne, J.Ph.

    2005-11-15

    The operating points obtained by the coupling of the power supply with the electric discharge system can be unstable because of the dynamical behaviour of the discharge or because of a change in its length. In this work, the different possible couplings existing between the discharge and the characteristics of its power supply are analyzed in order to optimize the design and control of the power supply and to control the operating point. Analytical and numerical modeling of the system are proposed which allow to simulate the couplings between the power supply and the discharge. This approach is completed by experimental investigations allowing to consider the cases of peak/peak discharges, dielectric barrier discharges (DBD), and gliding arcs. (J.S.)

  20. Environmental and economic assessment of discharges from Gulf of Mexico Region oil and gas operation. Quarterly technical progress report, 1 October--31 December 1994

    International Nuclear Information System (INIS)

    Gettleson, D.A.

    1995-01-01

    Task 3 (Environmental Field Sampling and Analysis of NORM, Heavy Metals, and Organics) work included analyses of samples. Task 4 (Monitoring of the Recovery of Impacted Wetland and Open Bay Produced Water Discharge Sites in Coastal Louisiana and Texas) activities involved the continued analyses of samples and field sampling at Bay de Chene. Task 5 (Assessment of Economic Impacts of Offshore and Coastal Discharge Requirements on Present and Future Operations in the Gulf of Mexico Region) activities included preparing a draft final report. Task 6 (Synthesis of Gulf of Mexico Seafood Consumption and Use Patterns) work also involved preparing a draft final report. Task 7 (Technology Transfer Plan) activities included a presentation at the Minerals Management Service Information Transfer Meeting for the Gulf of Mexico OCS Region. Task 8 (Project Management and Deliverables) activities involved the submission of the necessary reports and routine management

  1. Olkiluoto encapsulation and disposal plant; Determination of normal operation, upset and postulated accident conditions for radioactive release and dose assessment

    International Nuclear Information System (INIS)

    Kukkola, T.

    2009-08-01

    The radiation dose risks in the disposal plant are involved with the works in the encapsulation plant and in the disposal of the fuel canisters at the final repository. Radioactive materials are handled remote controlled in the shielded rooms in the encapsulation plant. The fuel canisters are closed in the radiation shield while handled in the repository. In the normal operation the major part of the personnel doses are caused by the spent fuel casks receiving. Also maintenance and repair work of the hot cell equipment and cleaning of the hot cell are causing personnel doses in normal operation. A small number of the fuel pins could loose their tightness and start to leak during the spent fuel transport to the disposal plant and in the fuel handling in the hot cell. A small number of the fuel pins has already loosed their tightness before the transport. Radioactive material fixed on the outer surfaces, crud, can also be released from the fuel pins and from the fuel channels. Most probable upset conditions are dealing with the fuel damages caused by the fuel handling errors in the fuel handling cell. The most serious accident is the spent fuel cask drop accident in the spent fuel cask transfer corridor. Special arrangements are needed in the accident management. (orig.)

  2. Psychosocial work strain of maintenance personnel during annual outage and normal operation in a nuclear power plant

    International Nuclear Information System (INIS)

    Jacobsson, L.; Svensson, O.

    1991-01-01

    This paper reports on a study which evaluates psychosocial work demands during the annual outage for a maintenance work group in a nuclear power plant. The study is based on a stress paradigm and it has been asserted that increased work strain would have a negative effect on performance. Nineteen workers, aged 20-55 years, participated in the study. The subjects filled out a questionnaire comparing work strain during annual outage and normal operation. During the outage period a 3-shift 24-hour work schedule, including nightwork, was used (working hours during normal operation was 7-16). Increased demands on concentration and vigilance, increased time pressure and strain on social relations within the group were found to characterize work during annual outage. Interestingly, for specific work tasks an association was found between the risk of making errors and high psychological workload. Increased work strain, shiftwork including nightwork and reduced social support are important psychosocial risk factors that might contribute to human error during the outage period

  3. Evaluation of the operating parameters of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry.

    Science.gov (United States)

    Zhang, Lynn X; Manard, Benjamin T; Konegger-Kappel, Stefanie; Kappel, Stefanie Konegger; Marcus, R Kenneth

    2014-11-01

    The liquid sampling-atmospheric pressure glow discharge (LS-APGD) has been assessed as an ionization source for elemental analysis with an interdependent, parametric evaluation regarding sheath/cooling gas flow rate, discharge current, liquid flow rate, and the distance between the plasma and the sampling cone of the mass spectrometer. In order to better understand plasma processes (and different from previous reports), no form of collision/reaction processing was performed to remove molecular interferents. The evaluation was performed employing five test elements: cesium, silver, lead, lanthanum and nickel (10(-4) mol L(-1) in 1 mol L(-1) HNO3). The intensity of the atomic ions, levels of spectral background, the signal-to-background ratios, and the atomic-to-oxide/hydroxide adduct ratios were monitored in order to obtain fundamental understanding with regards to not only how each parameter effects the performance of this LS-APGD source, but also the inter-parametric effects. The results indicate that the discharge current and the liquid sampling flow rates are the key aspects that control the spectral composition. A compromise set of operating conditions was determined: sheath gas flow rate = 0.9 L min(-1), discharge current = 10 mA, solution flow rate = 10 μL min(-1), and sampling distance = 1 cm. Limits of detection (LODs) were calculated using the SBR-RSDB (signal-to-background ratio/relative standard deviation of the background) approach under the optimized condition. The LODs for the test elementals ranged from 15 to 400 ng mL(-1) for 10 μL injections, with absolute mass values from 0.2 to 4 ng.

  4. Proposal for a new normalization reference in LCA based on “safe operating space”: presentation of framework and global factors at midpoint level

    DEFF Research Database (Denmark)

    Bjørn, Anders; Hauschild, Michael Zwicky

    Planetary boundaries have been suggested for a range of environmental impacts,such as climate change, eutrophying nutrients and land use. The boundaries demarcate the safe operating space of humanity: Staying within the space ensures environmental sustainability, while exceeding it risks pushing...... normalization factors in units compatible with characterized results at midpoint level in LCA. Our suggested framework allows expressing normalized results in units of “sustainable person years”. Normalization factors are derived by dividing the safe operating space by the global population. The proposed...... represent an important first step in enabling LCA to help guiding society in the direction of staying within the safe operating space....

  5. Shoulder replacement - discharge

    Science.gov (United States)

    Total shoulder arthroplasty - discharge; Endoprosthetic shoulder replacement - discharge; Partial shoulder replacement - discharge; Partial shoulder arthroplasty - discharge; Replacement - shoulder - discharge; Arthroplasty - shoulder - discharge

  6. Model, parameter and code of environmental dispersion of gaseous effluent under normal operation from nuclear power plant with 600 MWe

    International Nuclear Information System (INIS)

    Hu Erbang; Gao Zhanrong

    1998-06-01

    The model of environmental dispersion of gaseous effluence under normal operation from a nuclear power plant with 600 MWe is established to give a mathematical expression of annual mean atmospheric dispersion factor under mixing release condition based on quality assessment of radiological environment for 30 years of Chinese nuclear industry. In calculation, the impact from calm and other following factors have been taken into account: mixing layer, dry and wet deposition, radioactive decay and buildings. The doses caused from the following exposure pathways are also given by this model: external exposure from immersion cloud and ground deposition, internal exposure due to inhalation and ingestion. The code is named as ROULEA. It contains four modules, i.e. INPUT, ANRTRI, CHIQV and DOSE for calculating 4-dimension joint frequency, annual mean atmospheric dispersion factor and doses

  7. Extending the application range of a fuel performance code from normal operating to design basis accident conditions

    International Nuclear Information System (INIS)

    Van Uffelen, P.; Gyori, C.; Schubert, A.; Laar, J. van de; Hozer, Z.; Spykman, G.

    2008-01-01

    Two types of fuel performance codes are generally being applied, corresponding to the normal operating conditions and the design basis accident conditions, respectively. In order to simplify the code management and the interface between the codes, and to take advantage of the hardware progress it is favourable to generate a code that can cope with both conditions. In the first part of the present paper, we discuss the needs for creating such a code. The second part of the paper describes an example of model developments carried out by various members of the TRANSURANUS user group for coping with a loss of coolant accident (LOCA). In the third part, the validation of the extended fuel performance code is presented for LOCA conditions, whereas the last section summarises the present status and indicates needs for further developments to enable the code to deal with reactivity initiated accident (RIA) events

  8. Estimation of Extreme Responses and Failure Probability of Wind Turbines under Normal Operation by Controlled Monte Carlo Simulation

    DEFF Research Database (Denmark)

    Sichani, Mahdi Teimouri

    by the indicated so-called crude Monte Carlo method. With failure probabilities of the magnitude 10−7 during a 10 min. sampling interval the tails of the distributions are never encountered during normal operations. To circumvent this problem the application of variance reduction Monte Carlo methods i...... an alternative approach for estimation of the first excursion probability of any system is based on calculating the evolution of the Probability Density Function (PDF) of the process and integrating it on the specified domain. Clearly this provides the most accurate results among the three classes of the methods......Extreme value predictions for application in wind turbine design are often based on asymptotic results. Assuming that the extreme values of a wind turbine responses, i.e. maximum values of the mud-line moment or blades’ root stress, follow a certain but unknown probability density (mass...

  9. A comparison study of the two-bladed partial pitch turbine during normal operation and an extreme gust conditions

    DEFF Research Database (Denmark)

    Kim, Taeseong; Pedersen, Mads Mølgaard; Larsen, Torben J.

    2014-01-01

    This paper shows the load comparisons between the numerical simulation and the full-scale load measurement data. First part of this paper includes the comparisons of statistic load in terms of maximum, mean, and minimum values for the selected normal operation cases. The blade root bending moments...... and tower top bending moments are compared. Second part of this paper introduces the dynamic response comparisons during an extreme wind gust condition where the wind speed changed approximately 10 m/s during three seconds. The rotor speed and blade root flapwise and edgewise bending moment are compared....... The nonlinear aeroelastic simulation code HAWC2 is used for the simulations. A very fine agreement between the simulated and the full-scale measured loads is seen for the both comparisons....

  10. Diverse mode of operation of an all-normal-dispersion mode-locked fiber laser employing two nonlinear loop mirrors.

    Science.gov (United States)

    Chowdhury, Sourav Das; Pal, Atasi; Chatterjee, Sayan; Sen, Ranjan; Pal, Mrinmay

    2018-02-10

    In this paper, we propose an all-normal-dispersion ytterbium-fiber laser with a novel ring cavity architecture having two nonlinear amplifying loop mirrors (NALM) as saturable absorbers, capable of delivering distinctly different pulses with adjustable features. By optimizing the loop lengths of the individual NALMs, the cavity can be operated to deliver Q-switched mode-locked (Q-ML) pulse bunches with adjustable repetition rates, mode-locked pulses in dissipative soliton resonance (DSR) regime or noise-like pulse (NLP) regime with tunable pulse width. The DSR pulses exhibit characteristic narrowband spectrum, while the NLPs exhibit large broadband spectrum. The operation regime of the laser can be controlled by adjusting the amplifier pump powers and the polarization controllers. To the best of the authors' knowledge, this is the first demonstration of a single mode-locked cavity where narrowband DSR pulses and broadband NLPs alongside Q-ML pulse bunches can be selectively generated by employing two NALMs.

  11. Measurement of fission gas release, internal pressure and cladding creep rate in the fuel pins of PHWR bundle of normal discharge burnup

    Science.gov (United States)

    Viswanathan, U. K.; Sah, D. N.; Rath, B. N.; Anantharaman, S.

    2009-08-01

    Fuel pins of a Pressurised Heavy Water Reactor (PHWR) fuel bundle discharged from Narora Atomic Power Station unit #1 after attaining a fuel burnup of 7528 MWd/tU have been subjected to two types of studies, namely (i) puncture test to estimate extent of fission gas release and internal pressure in the fuel pin and (ii) localized heating of the irradiated fuel pin to measure the creep rate of the cladding in temperature range 800 °C-900 °C. The fission gas release in the fuel pins from the outer ring of the bundle was found to be about 8%. However, only marginal release was found in fuel pins from the middle ring and the central fuel pin. The internal gas pressure in the outer fuel pin was measured to be 0.55 ± 0.05 MPa at room temperature. In-cell isothermal heating of a small portion of the outer fuel pins was carried out at 800 °C, 850 °C and 900 °C for 10 min and the increase in diameter of the fuel pin was measured after heat treatment. Creep rates of the cladding obtained from the measurement of the diameter change of the cladding due to heating at 800 °C, 850 °C and 900 °C were found respectively to be 2.4 × 10 -5 s -1, 24.6 × 10 -5 s -1 and 45.6 × 10 -5 s -1.

  12. After-discharges and seizures during pediatric extra-operative electrical cortical stimulation functional brain mapping: Incidence, thresholds, and determinants.

    Science.gov (United States)

    Aungaroon, Gewalin; Zea Vera, Alonso; Horn, Paul S; Byars, Anna W; Greiner, Hansel M; Tenney, Jeffrey R; Arthur, Todd M; Crone, Nathan E; Holland, Katherine D; Mangano, Francesco T; Arya, Ravindra

    2017-10-01

    This study examined the incidence, thresholds, and determinants of electrical cortical stimulation (ECS)-induced after-discharges (ADs) and seizures. Electrocorticograph recordings were reviewed to determine incidence of ECS-induced ADs and seizures. Multivariable analyses for predictors of AD/seizure occurrence and their thresholds were performed. In 122 patients, the incidence of ADs and seizures was 77% (94/122) and 35% (43/122) respectively. Males (odds ratio [OR] 2.92, 95% CI 1.21-7.38, p=0.02) and MRI-negative patients (OR 3.69, 95% CI 1.24-13.7, p=0.03) were found to have higher odds of ECS-induced ADs. A significant trend for decreasing AD thresholds with age was seen (regression co-efficient -0.151, 95% CI -0.267 to -0.035, p=0.011). ECS-induced seizures were more likely in patients with lateralized functional imaging (OR 6.62, 95% CI 1.36-55.56, p=0.036, for positron emission tomography) and presence of ADs (OR 3.50, 95% CI 1.12-13.36, p=0.043). ECS is associated with a high incidence of ADs and seizures. With age, current thresholds decrease and the probability for AD/seizure occurrence increases. ADs and seizures during ECS brain mapping are potentially hazardous and affect its functional validity. Thus, safer method(s) for brain mapping with improved neurophysiologic validity are desirable. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  13. FIELD EVALUATION OF IMPROVED METHODS FOR MEASURING THE AIR LEAKAGE OF DUCT SYSTEMS UNDER NORMAL OPERATING CONDITIONS IN 51 HOMES

    Energy Technology Data Exchange (ETDEWEB)

    Paul W. Francisco; Larry Palmiter; Erin Kruse; Bob Davis

    2003-10-18

    Duct leakage in forced-air distribution systems has been recognized for years as a major source of energy losses in residential buildings. Unfortunately, the distribution of leakage across homes is far from uniform, and measuring duct leakage under normal operating conditions has proven to be difficult. Recently, two new methods for estimating duct leakage at normal operating conditions have been devised. These are called the nulling test and the Delta-Q test. Small exploratory studies have been done to evaluate these tests, but previously no large-scale study on a broad variety of homes has been performed to determine the accuracy of these new methods in the field against an independent benchmark of leakage. This sort of study is important because it is difficult in a laboratory setting to replicate the range of leakage types found in real homes. This report presents the results of a study on 51 homes to evaluate these new methods relative to an independent benchmark and a method that is currently used. An evaluation of the benchmark procedure found that it worked very well for supply-side leakage measurements, but not as well on the return side. The nulling test was found to perform well, as long as wind effects were minimal. Unfortunately, the time and difficulty of setup can be prohibitive, and it is likely that this method will not be practical for general use by contractors except in homes with no return ducts. The Delta-Q test was found to have a bias resulting in overprediction of the leakage, which qualitatively confirms the results of previous laboratory, simulation, and small-scale field studies. On average the bias was only a few percent of the air handler flow, but in about 20% of the homes the bias was large. A primary flaw with the Delta-Q test is the assumption that the pressure between the ducts and the house remain constant during the test, as this assumption does not hold true. Various modifications to the Delta-Q method were evaluated as

  14. Development and Implementation of Mechanistic Terry Turbine Models in RELAP-7 to Simulate RCIC Normal Operation Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Haihua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zou, Ling [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); O' Brien, James Edward [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-09-01

    As part of the efforts to understand the unexpected “self-regulating” mode of the RCIC (Reactor Core Isolation Cooling) systems in Fukushima accidents and extend BWR RCIC and PWR AFW (Auxiliary Feed Water) operational range and flexibility, mechanistic models for the Terry turbine, based on Sandia’s original work [1], have been developed and implemented in the RELAP-7 code to simulate the RCIC system. In 2016, our effort has been focused on normal working conditions of the RCIC system. More complex off-design conditions will be pursued in later years when more data are available. In the Sandia model, the turbine stator inlet velocity is provided according to a reduced-order model which was obtained from a large number of CFD (computational fluid dynamics) simulations. In this work, we propose an alternative method, using an under-expanded jet model to obtain the velocity and thermodynamic conditions for the turbine stator inlet. The models include both an adiabatic expansion process inside the nozzle and a free expansion process outside of the nozzle to ambient pressure. The combined models are able to predict the steam mass flow rate and supersonic velocity to the Terry turbine bucket entrance, which are the necessary input information for the Terry turbine rotor model. The analytical models for the nozzle were validated with experimental data and benchmarked with CFD simulations. The analytical models generally agree well with the experimental data and CFD simulations. The analytical models are suitable for implementation into a reactor system analysis code or severe accident code as part of mechanistic and dynamical models to understand the RCIC behaviors. The newly developed nozzle models and modified turbine rotor model according to the Sandia’s original work have been implemented into RELAP-7, along with the original Sandia Terry turbine model. A new pump model has also been developed and implemented to couple with the Terry turbine model. An input

  15. Locating Shallow Groundwater Discharge to Streams Near Concentrated Animal Feeding Operations Using Aerial Infrared Thermography: A Novel Potential Pollution Detection Method

    Science.gov (United States)

    Mapes, K. L.; Pricope, N. G.

    2017-12-01

    The Cape Fear River Basin (CFRB) has some of the highest densities of concentrated animal feeding operations (CAFO) in the United States (factoryfarmmap.org) and was recently named one of the country's most endangered rivers (americanrivers.org). There is high potential for CAFO land use to degrade stream water quality by introducing pollutants, primarily nitrates and fecal coliform, into sub-surface and surface waters. The regionally high water table in the Lower CFRB increases the risk of water quality degradation due to increased connectivity of ground- and surface water. The Lower CFRB is periodically subjected to frequent or intense hurricanes, which have been shown to exacerbate water quality issues associated with CAFOs. Additionally, the growing population in this region is placing more pressure on an already taxed water source and will continue to rely on the Cape Fear River for drinking water and wastewater discharge. While there are documented occurrences of groundwater contamination from CAFOs, we still have little understanding on how and where pollution may be entering streams by shallow sub-surface discharge. Shallow groundwater discharge to streams is becoming easier to detect using thermal infrared imaging cameras onboard unmanned aerial systems. The temperature differences between groundwater and stream water are easily distinguished in the resulting images. While this technology cannot directly measure water quality, it can locate areas of shallow groundwater discharge that can later be tested for pollutants using conventional methods. We will utilize a thermal infrared camera onboard a SenseFly eBee Plus to determine the feasibility of using this technology on a larger scale within the Lower CFRB as an inexpensive means of identifying sites of potential pollution input. Aerial surveys will be conducted in two sub-watersheds: one containing swine CAFO and a control that lacks swine CAFO. Information from this study can be integrated into

  16. Statistical forecast of seasonal discharge in Central Asia using observational records: development of a generic linear modelling tool for operational water resource management

    Science.gov (United States)

    Apel, Heiko; Abdykerimova, Zharkinay; Agalhanova, Marina; Baimaganbetov, Azamat; Gavrilenko, Nadejda; Gerlitz, Lars; Kalashnikova, Olga; Unger-Shayesteh, Katy; Vorogushyn, Sergiy; Gafurov, Abror

    2018-04-01

    The semi-arid regions of Central Asia crucially depend on the water resources supplied by the mountainous areas of the Tien Shan and Pamir and Altai mountains. During the summer months the snow-melt- and glacier-melt-dominated river discharge originating in the mountains provides the main water resource available for agricultural production, but also for storage in reservoirs for energy generation during the winter months. Thus a reliable seasonal forecast of the water resources is crucial for sustainable management and planning of water resources. In fact, seasonal forecasts are mandatory tasks of all national hydro-meteorological services in the region. In order to support the operational seasonal forecast procedures of hydro-meteorological services, this study aims to develop a generic tool for deriving statistical forecast models of seasonal river discharge based solely on observational records. The generic model structure is kept as simple as possible in order to be driven by meteorological and hydrological data readily available at the hydro-meteorological services, and to be applicable for all catchments in the region. As snow melt dominates summer runoff, the main meteorological predictors for the forecast models are monthly values of winter precipitation and temperature, satellite-based snow cover data, and antecedent discharge. This basic predictor set was further extended by multi-monthly means of the individual predictors, as well as composites of the predictors. Forecast models are derived based on these predictors as linear combinations of up to four predictors. A user-selectable number of the best models is extracted automatically by the developed model fitting algorithm, which includes a test for robustness by a leave-one-out cross-validation. Based on the cross-validation the predictive uncertainty was quantified for every prediction model. Forecasts of the mean seasonal discharge of the period April to September are derived every month from

  17. PLZT Electrooptic Ceramic Photonic Devices for Surface-Normal Operation in Trenches Cut Across Arrays of Optical Fiber

    Science.gov (United States)

    Hirabayashi, Katsuhiko

    2005-03-01

    Simple Pb_1-x La_x(Zr_y Ti_z)_1-x/4 O3 (PLZT) electrooptic ceramic photonic device arrays for surface-normal operation have been developed for application to polarization-controller arrays and Fabry-Pérot tunable filter arrays. These arrays are inserted in trenches cut across fiber arrays. Each element of the arrayed structure corresponds to one optical beam and takes the form of a cell. Each sidewall of the cell (width: 50-80 μm) is coated to form an electrode. The arrays have 16 elements at a pitch of 250 μm. The phase modulator has about 1 dB of loss and a half-wavelength voltage of 120 V. A cascade of two PLZT phase modulators (thickness: 300 μm), with each attached to a polyimide lambda/2 plate (thickness:15 μm), is capable of converting an arbitrary polarization to the transverse-electric (TE) or transverse-magnetic (TM) polarization. The response time is 1 μs. The Fabry-Pérot tunable filters have a thickness of 50 μm . The front and back surfaces of each cell are coated by 99%-reflective mirror. The free spectral range (FSR) of the filters is about 10 nm, tunable range is about 10 nm, loss is 2.2 dB, and finesse is 150. The tuning speed of these devices is high, taking only 1 μs.

  18. Behavior of U3Si2 Fuel and FeCrAl Cladding under Normal Operating and Accident Reactor Conditions

    International Nuclear Information System (INIS)

    Gamble, Kyle Allan Lawrence; Hales, Jason Dean; Barani, Tommaso; Pizzocri, Davide; Pastore, Giovanni

    2016-01-01

    As part of the Department of Energy's Nuclear Energy Advanced Modeling and Simulation program, an Accident Tolerant Fuel High Impact Problem was initiated at the beginning of fiscal year 2015 to investigate the behavior of \\usi~fuel and iron-chromium-aluminum (FeCrAl) claddings under normal operating and accident reactor conditions. The High Impact Problem was created in response to the United States Department of Energy's renewed interest in accident tolerant materials after the events that occurred at the Fukushima Daiichi Nuclear Power Plant in 2011. The High Impact Problem is a multinational laboratory and university collaborative research effort between Idaho National Laboratory, Los Alamos National Laboratory, Argonne National Laboratory, and the University of Tennessee, Knoxville. This report primarily focuses on the engineering scale research in fiscal year 2016 with brief summaries of the lower length scale developments in the areas of density functional theory, cluster dynamics, rate theory, and phase field being presented.

  19. Birth defects in perinatal infants in areas contiguous to Hongyanhe Nuclear Power Plant before its normal operation

    International Nuclear Information System (INIS)

    Zhou Ling; Yin Zhihua; Han Zhonghui

    2011-01-01

    Objective: To understand the status of birth defects among the perinatal infants in the areas contiguous to Hongyanhe nuclear power plant before its normal operation, so as to provide background information for the evaluation of the impact of nuclear power plant on birth defects. Methods: From 1 October 1995 to 30 September 2009 the midwifery units at second class and above of Wafangdian City were asked to be in charge of recording the birth defects among the perinatal infants born during this period within the range of 50 km around the Hongyanhe nuclear power plant. Results: The total number of birth defects was 697, and the maternal number Was 83779. The average defect rate Was 83.20/10 4 . There were significant differences in the birth defect rate among different years (χ 2 =39.54, P<0.05), however, without linear trend therein,and among the survey areas (χ 2 =15.36, P<0.05) as well. The top five birth defects were congenital heart disease (148 cases), cleft lip with cleft palate (67 cases), congenital hydrocephalus (63 cases), and spina bifida (37 cases) and cleft lip (36 cases). Conclusions: The birth defect rate within the range of 50 km around the Hongyanhe nuclear power plant is lower than that of the region of Liaoning Province and the national rate of birth defects. (authors)

  20. NIPPLE DISCHARGE

    Directory of Open Access Journals (Sweden)

    T. N. Bukharova

    2008-01-01

    Full Text Available According to the data available in the literature, as high as 50% of women have benign breast tumors frequently accompanied by nip- ple discharge. Nipple discharge may be serous, bloody, purulent, and colostric. The most common causes are breast abscess, injury, drugs, prolactinoma, intraductal pappiloma, ductal ectasia, intraductal cancer (not more than 10%.

  1. Examination of Deposited Layers Composition on the Discharge Chamber Constructional Elements Tokamak T-11M after Two-Year Operation with Lithium Limiter

    International Nuclear Information System (INIS)

    Buzhinskij, O.; Barsuk, V.

    2006-01-01

    In this work the results of the research of internal structural elements state of the T11-M tokamak discharge chamber after two-year operation with lithium limiter are given [V.B. Lazarev, E.A. Azizov et al., Compatibility of the Lithium Capillary Limiter with Plasma in T-11M, 26 th EPS Conf. on Contr. Fusion Plasma Physics, ECA, vol. 231, pp. 845-848, 1999, V.A. Evtikhin, I.E. Lyublinski, A.V. Vertkov et al., Technology Aspects of Lithium Capillary pore Systems Application in Tokamak Device, SOFT-21 (Madrid), A-37, 2000]. The condition of molybdenic wall surface of the discharge chamber and internal steel surface of diagnostic ports has been investigated. X-ray microanalysis of deposited surface of the first wall has shown, that in deposited layer are contained in the main Mo and small amount Cu. In a composition of deposited layer on the ports surface, except the above-named elements, in a small amount is Fe. Because of the instrumental restrictions of this method of analysis, detection opportunity of lithium traces was missing. X-ray diffractometer analysis of deposited layer on the first wall surface has detected a mixture of several phases. The main phase is Li 2 CO 3 , one third from all deposited substance is Li 2 MoO 4 , there is also LiOH-HO phase. The deposited layer on diagnostic ports in the main consists of LiOH-H 2 O phase, there is also Li 2 CO 3 phase. The results of X-ray analysis of a dust probe from the B 4 C coated graphite limiter surface have not detected whatever extra phases, except a crystalline boron carbide phase. (author)

  2. Ileostomy - discharge

    Science.gov (United States)

    ... dried fruits (such as raisins), mushrooms, chunky relishes, coconut, and some Chinese vegetables. Tips for when no ... ask your doctor Living with your ileostomy Low-fiber diet Small bowel resection - discharge Total colectomy or ...

  3. Process-oriented dose assessment model for 14C due to releases during normal operation of a nuclear power plant

    International Nuclear Information System (INIS)

    Aquilonius, Karin; Hallberg, Bengt

    2005-01-01

    Swedish nuclear utility companies are required to assess doses due to releases of radionuclides during normal operation. In 2001, calculation methods used earlier were updated due to new authority regulations. The isotope 14 C is of special interest in dose assessments due to the role of carbon in the metabolism of all life forms. Earlier, factors expressing the ratio between concentration of 14 C in air and in various plants were used. In order to extend the possibility to take local conditions into account, a process-oriented assessment model for uptake of carbon and doses from releases of 14 C to air was developed (POM 14 C). The model uses part of Daisy which has been developed to model the turnover of carbon in crops. [Hansen, S., Jensen, H.E., Nielsen, N.E., Svendsen, H., 1993. Description of the Soil Plant System Model DAISY, Basic Principles and Modelling Approach. Simulation Model for Transformation and Transport of Energy and Matter in the Soil Plant Atmosphere System. Jordbruksfoerlaget, The Royal Veterianary and Agricultural University, Copenhagen, Denmark]. The main objectives were to test model performance of the former method, and to investigate if taking site specific parameters into account to a greater degree would lead to major differences in the results. Several exposure pathways were considered: direct consumption of locally grown cereals, vegetables, and root vegetables, as well as consumption of milk and meat from cows having eaten fodder cereals and green fodder from the area around the nuclear plant. The total dose of the earlier model was compared with that of POM 14 C. The result of the former was shown to be slightly higher than the latter, but POM 14 C confirmed that the earlier results were of a reasonable magnitude. When full account of local conditions was taken, e.g. as regards solar radiation, temperature, and concentration of 14 C in air at various places in the surroundings of each nuclear plant, a difference in dose between

  4. Proposal for a new normalization reference in LCA based on “safe operating space”: presentation of framework and global factors at midpoint level

    DEFF Research Database (Denmark)

    Bjørn, Anders; Hauschild, Michael Zwicky

    Planetary boundaries have been suggested for a range of environmental impacts,such as climate change, eutrophying nutrients and land use. The boundaries demarcate the safe operating space of humanity: Staying within the space ensures environmental sustainability, while exceeding it risks pushing...... occupies. We propose that such an indicator system can be applied in life cycle assessment (LCA) by integrating planetary boundaries via the normalization step. We present the framework of integration, a literature review of quantified boundaries and resulting normatively consistent global average...... normalization factors were compared with existing normalization factors that are based on global impacts currently taking place. The impact categories climate change, land use and terrestrial acidification were found to have their safe operating space exceeded on average globally, while the opposite was true...

  5. Dose conversion factors for radiation doses at normal operation discharges. E. Exposure pathways and radioecological data; Dosomraekningsfaktorer foer normaldriftutslaepp. C. Exponeringsvaegar och radioekologiska data

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, Sara; Aquilonius, Karin

    2001-10-01

    A study has been performed in order to develop and extend existing models for dose estimations at emissions of radioactive substances from nuclear facilities in Sweden. This report presents a review of all exposure pathways in the project, in order to secure that no important contributions have been omitted. The radioecological data that should be used in calculating conversion factors for air and water emissions are also reviewed. Nuclid-specific conversion factors have been calculated for radiation doses from inhalation and intake for children in different age groups.

  6. XeCl avalanche discharge laser employing Ar as a diluent

    Science.gov (United States)

    Sze, R.C.

    1979-10-10

    A XeCl avalanche discharge exciplex laser which uses a gaseous lasing starting mixture of: 0.2 to 0.4% chlorine donor/2.5% to 10% Xe/97.3% to 89.6% Ar) is provided. The chlorine donor normally comprises HCl but can also comprise CCl/sub 4/ BCl/sub 3/. Use of Ar as a diluent gas reduces operating pressures over other rare gas halide lasers to near atmospheric pressure, increases output lasing power of the XeCl avalanche discharge laser by 30% to exceed KrF avalanche discharge lasing outputs, and is less expensive to operate.

  7. A novel approach for evaluating acceptable intra-operative correction of lower limb alignment in femoral and tibial malunion using the deviation angle of the normal contralateral knee.

    Science.gov (United States)

    Wu, Chi-Chuan

    2014-03-01

    A simple and appropriate approach for evaluating an acceptable alignment of bone around the knee during operation has not yet been reported. Thirty-five men and 35 women presenting with nonunion or malunion of the unilateral femoral shaft were included in the first study. Using the standing scanograph, the contralateral normal lower extremity was measured to determine the normal deviation angle (DA) of the medial malleolus when the medial aspect of the knee was placed in the midline of the body. In the second study, the normal DA from individual patients was used as a reference to evaluate knee alignment during operation in 40 other patients presenting with distal femoral or proximal tibial nonunion or malunion. The clinical and knee functional outcomes of these 40 patients were investigated. The average normal DA was 4.2° in men and 6.0° in women (palignment was maintained in all 30 patients with fracture union. Satisfactory function of the knee was achieved in 28 patients (82%, palignment of bone around the knee during operation. Level IV, Case series. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Chaos in gas discharges

    International Nuclear Information System (INIS)

    Piel, A.

    1993-01-01

    Many gas discharges exhibit natural oscillations which undergo a transition from regular to chaotic behavior by changing an experimental parameter or by applying external modulation. Besides several isolated investigations, two classes of discharge phenomena have been studied in more detail: ionization waves in medium pressure discharges and potential relaxation oscillations in filament cathode discharges at very low pressure. The latter phenomenon will be discussed by comparing experimental results from different discharge arrangements with particle-in-cell simulations and with a model based on the van-der-Pol equation. The filament cathode discharge has two stable modes of operation: the low current anode-glow-mode and the high current temperature-limited-mode, which form the hysteresis curve in the I(U) characteristics. Close to the hysteresis point of the AGM periodic relaxation oscillations occur. The authors demonstrate that the AGM can be understood by ion production in the anode layer, stopping of ions by charge exchange, and trapping in the virtual cathode around the filament. The relaxation oscillations consist of a slow filling phase and a rapid phase that invokes formation of an unstable double-layer, current-spiking, and ion depletion from the cathodic plasma. The relaxation oscillations can be mode-locked by external modulation. Inside a mode-locked state, a period doubling cascade is observed at high modulation degree

  9. Derived release limits (DRL's) for airborne and liquid effluents from the Chalk River Nuclear Laboratories during normal operations

    International Nuclear Information System (INIS)

    Palmer, J.F.

    1981-02-01

    Derived release limits (DRL's), based on regulatory dose limits, have been calculated for routine discharges of radioactivity in airborne and liquid effluents from the Chalk River Nuclear Laboratories. Three types of sources of airborne effluents were considered: the NRX/NRU stack, the 61 m stack connected to the 99 Mo production facility, and a roof vent typical of those installed on several buildings on the site. Sources of liquid effluents to the Ottawa River were treated as a single source from the site as a whole. Various exposure pathways to workers on the site and to members of the public outside the site boundary were considered in the calculations. The DRL's represent upper limits for routine emissions of radioactivity from the Chalk River Nuclear Laboratories to the surrounding environment. Actual releases are regulated by Administrative Levels, set lower than the DRL's, and are confirmed by monitoring. (author)

  10. Testing post-weaning food motivation in low and normal birth weight pigs in a runway and operant conditioning task

    NARCIS (Netherlands)

    van Eck, L. M.; Antonides, A.; Nordquist, R. E.; van der Staay, F. J.

    2016-01-01

    Low birth weight (LBW) pigs face more welfare challenges than their normal birth weight (NBW) siblings. Understanding the underlying mechanisms of cognitive and learning abilities in these pigs may help to improve their welfare. Early competition in life over resources, combined with the higher need

  11. Testing post-weaning food motivation in low and normal birth weight pigs in a runway and operant conditioning task

    NARCIS (Netherlands)

    Eck, van L.M.; Antonides, A.; Nordquist, R.E.; Staay, van der F.J.

    2016-01-01

    Low birth weight (LBW) pigs face more welfare challenges than their normal birth weight (NBW) siblings. Understanding the underlying mechanisms of cognitive and learning abilities in these pigs may help to improve their welfare. Early competition in life over resources, combined with the higher

  12. Esophagectomy - discharge

    Science.gov (United States)

    ... 000241.htm Esophagectomy - discharge To use the sharing features on this page, please enable JavaScript. You had ... up or down stairs, or ride in a car. Be sure to rest after being active. If it hurts when ... In the bathroom , install safety bars to help you get in and out ...

  13. Mastectomy - discharge

    Science.gov (United States)

    ... had breast reconstruction surgery with implants or natural tissue . What to Expect at Home Full recovery may take ... lump removal Breast reconstruction - implants Breast reconstruction - natural ... breast surgery - discharge Mastectomy and breast reconstruction - what to ask your doctor Wet-to-dry dressing ...

  14. Method for supervising and controlling the charging and discharging operations of fuel in a nuclear reactor and apparatus for applying this method

    International Nuclear Information System (INIS)

    Plumier, M.

    1985-01-01

    Method is described for supervising and controlling the charging and discharging operations, in nuclear fuel element assemblies, of a core of a reactor, of a reactor pond and of a decontamination pond, by means of a charging machine equipped with a telescopic mast the end of which is provided with a gripping head with grippers, serving the reactor and the reactor pond in which there is arranged a buffer storage rack, a fixed depositing station and a mobile depositing station, and by means of a charging machine equipped with a telescopic mast the end of which is provided with a gripping head with grippers, serving the decontamination pond containing storage racks, and by means of a transfer device providing communication between the reactor pond and the decontamination pond, characterised in that the initial position in each assembly in the core of the reactor, in the storage racks and possibly in the buffer rack is recorded, in that the position of the charging machine and/or of the handling machine and/or of the transfer device and/or of the mobile depositing station is recorded, likewise the identification of the assembly at the time of each taking up of an assembly and/or at the time of each placing of an assembly in the core of the reactor, in the buffer rack in the transfer basket, in the storage rack, in the fixed depositing station and in the mobile depositing station, in that the command and control signals for each manipulation required of the charging machine, of the handling machine, of the transfer device and of any other mobile station are compared with the recorded signals of a preestablished charging sequence. 5 refs., 4 figs

  15. The calculating methods of the release of airborne radionuclides to environment during the normal operation of a module high temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Liu Yuanzhong

    1993-01-01

    The calculations of the release of radionuclides to environment are the basis of environmental impact assessment during the normal operation of a module high temperature gas-cooled reactor of the Institute of Nuclear Energy Technology, Tsinghua University, China. According to the features of the reactor it is pointed out that only five sources of the airborne radioactive materials released to environment are important. They are: (1) the activation of the air in the reactor cavity; (2) the escape from the primary coolant systems; (3) the release of radioactively contaminated helium from storage tanks; (4) the release of radioactively contaminated helium from the gas evacuation system of fuel load and unload system; (5) the leakage of the vapour from water-steam loop. In accordance with five release sources the calculating methods of radionuclides released to environment are worked out respectively and the respective calculating formulas are derived for the normal operation of the reactor

  16. An assessment of the failure rate for the beltline region of PWR pressure vessels during normal operation and certain transient conditions. Technical report

    International Nuclear Information System (INIS)

    Gamble, R.M.; Strosnider, J. Jr.

    1981-06-01

    A study was conducted to assess the failure rate for the beltline region of a generic pressurized-water reactor (PWR) pressure vessel. This assessment included the evaluation of several normal operating and transient reactor conditions. Failure rates were calculated from a computer code that used fracture mechanics methods to model the failure process; random number generation techniques were used to simulate random variables and model their interaction in the failure-process. This investigation had three major objectives: (1) to better define the effect of neutron irradiation, material variation, and flaw distribution on the failure rate for the beltline region of PWR pressure vessels, (2) to estimate the relative margins against failure for normal operation and certain transient conditions associated with nuclear pressure vessels, and (3) to evaluate the current limitations for using fracture mechanics models to predict failure rates for nuclear pressure vessels

  17. Annual report on radioactive discharges and monitoring of the environment, 1996. V. 1

    International Nuclear Information System (INIS)

    1997-01-01

    British Nuclear Fuels Limited (BNFL)'s 1996 report on radioactive discharges from its various sites and monitoring of the surrounding environments are described. For each of the Sellafield, Drigg, Chapelcross, Springfields and Capenhurst sites, details are given on normal operations, radioactive discharges in gaseous, liquid or solid forms, environmental monitoring routines and collective dose and critical group estimates. The second, linked, volume of this report covers certificates of authorisation issued to the company. (UK)

  18. Construction of an external electrode for determination of electrochemical corrosion potential in normal operational conditions of an BWR type reactor for hot cells

    International Nuclear Information System (INIS)

    Aguilar T, J.A.; Rivera M, H.; Hernandez C, R.

    2001-01-01

    The behavior of the corrosion processes at high temperature requires of external devices that being capable to resist a temperature of 288 Centigrade and a pressure of 80 Kg/cm 2 , to give stable and reproducible results of some variable and resisting physically and chemically the radiation. The external electrode of Ag/AgCl fulfils all the requirements in the determination of the electrochemical corrosion potential under normal operational conditions of a BWR type reactor in hot cells. (Author)

  19. An effort to improve the operators' habits of actions in normal operations and in disturbance situations at TVO NPP in Finland

    International Nuclear Information System (INIS)

    Karlsson, C.

    2004-01-01

    Teollisuuden Voima Oy owns and operates two ABB BWR's, each of 850 MW net outputs. A full-scope training simulator was commissioned in March 1990 at the TVO Olkiluoto plant site. This paper discusses the development of a method to evaluate and improve the operators' habits of actions in a task performance at the Teollisuuden Voima Oy full-scope training simulator. The development of the method started as a study in autumn 1992 and the first goal of the study was to analyse the dynamics of operators' decision making in the on-line control of a disturbance situation. The analysis was ready in 1994. The second goal was to develop out of the analysis method a tool that could serve as the instructor's in evaluating the individuals and the crew's simulator performances. It was assumed that such a tool would enhance the efficiency of the simulator training, because with it the instructors could provide more explicit performance feedback for the operators. The next stage was to apply the method to the entire simulator training and create a course, which consists of a theoretical part and practical training on the simulator. That was done in the retraining period in 1998. The future goals are to improve the method so that it will be used in all the simulator training at the Teollisuuden Voima Oy full-scope training simulator (OLKS). (author)

  20. Rapid Downstream Discharge Attenuation During Recent Icelandic Jokulhlaups

    Science.gov (United States)

    Russell, A. J.; Roberts, M. J.; Tweed, F. S.; Knudsen, O.; Harris, T. D.; Rushmer, E. L.; Marren, P. M.; Carrivick, J. L.

    2002-12-01

    Little attention has been paid to downstream discharge attenuation during glacier outburst floods (jokulhlaups). In non-glacial environments, floods resulting from dam failure exhibit major downstream reduction of peak discharge. Transmission losses within ephemeral rivers are also well-known for generating large reductions in peak discharge. We report on three recent jokulhlaups associated with major downstream discharge attenuation: (1) Solheimajokull July 1999; (2) Kverkjokull January 2002; and (3) Tungnaarjokull July 2002. Peak discharges calculated using slope area techniques showed that the 1999 Solheimahlaup decreased in discharge from 4400 m3s-1 to 1700 m3s-1 over a downstream distance of less than 7 km. The Kverkhlaup was gauged at 400 m3s-1, 40 km downstream of the glacier snout. By contrast, less than 1 km from the glacier snouta peak discharge of 2000 m3s-1 was reconstructed using slope-area techniques. The July 2002 jokulhlaup from Tungnaarjokull had a gauged peak discharge of 600 m3s-1 23 km downstream of the glacier snout. Discharge reconstructed at the glacier snout was ~2-3 times greater than the downstream gauged value. The degree of downstream attenuation of these jokulhlaups reflects a number of factors. The rapidity of rising stage water release. The drainage of warm water during these three jokulhlaups is thought to have resulted in a characteristic sudden, short-lived, rise to peak discharge. In the case of the 1999 Solheimahlaup the hydrograph peak was enhanced by a wave-like burst from a flood-filled ice-dammed lake basin. Flow through high resistance complex bedrock (lava) and braided channels is effective in damping j”kulhlaup peak discharge. Transmission loss into highly permeable substrate materials such as lava flows and alluvium visibly reduce peak discharge under normal flow conditions will also be significant during jokulhlaups which flow through wide reaches. Our study of three recent Icelandic jokulhlaups illustrates the

  1. I've Never Had My Period, So What Is This Discharge?

    Science.gov (United States)

    ... first period, her body may start to produce vaginal discharge. This is normal and is caused by the ... This discharge helps keep the vagina healthy. Normal vaginal discharge can have a texture that's anywhere from thin ...

  2. Radiological discharges

    International Nuclear Information System (INIS)

    Woodliffe, J.

    1990-01-01

    Current practice of North Sea States on the discharge and disposal of liquid radioactive wastes to the North Sea are based on the declaration issued at the Second International Conference on the Protection of the North Sea, known as the London Declaration. This has three main points the first of which emphasises the application of the Best Available Technology to protect the North Sea, the second provides a framework on which future controls on radioactive discharges should be based. The third identifies two parts of the framework; to take into account the recommendations of international organizations and that any repositories of radioactive waste which are built should not pollute the North Sea. This chapter looks at how the concensus based on the London Declaration is working, gauges the progress made in the implementation of the policy goal, identifies existing and future areas for concern and proposes ways of strengthening the control of radioactive discharges. The emphasis is on the United Kingdom practice and regulations for liquid wastes, most of which comes from the Sellafield Reprocessing Plant. (author)

  3. The protection of operating personnel in nuclear power plants against the risk of nuclear incidents and ionizing radiation arising from normal operation of the plant. Rules and problems

    International Nuclear Information System (INIS)

    Ortore, F.; Scalera, D.

    1980-03-01

    After an analysis of the nuclear third party liability insurance policy to be taken out in Italy in implementation of Act no. 1860 of 31 December 1962 and Decree No. 519 of 10 May 1979, the collective policy against radiation injuries taken out for operating personnel in nuclear installations is described. The author is in favour of further harmonization of the legal system presently in force in this respect. (NEA) [fr

  4. Conceptual analysis of a preliminary model for instability study in normal operation of a natural circulation reactor type EBWR, using Relap5/Mod 3.2

    International Nuclear Information System (INIS)

    Ojeda S, J.; Morales S, J.; Chavez M, C.

    2009-10-01

    This work intends a model using the code Relap5/Mod 3.2, for the instability study in normal operation of a natural circulation reactor type ESBWR. A conceptual analysis is considered because all the information was obtained of the open literature, and some of reactor operation or dimension (not available) parameters were approached. As starting point was took the pattern developed for reactor type BWR, denominated Browns Ferry and changes were focused in elimination of bonds of forced recirculation, in modification of operation parameters, dimensions and own control parameters, according to internal code structure. Additionally the nodalization outline is described analyzing for separate the four fundamental areas employees in peculiar geometry of natural circulation reactor. Comparative analysis of results of stability behavior obtained with those reported in the open literature were made, by part of commercial reactor designer ESBWR. (Author)

  5. Addendum to the Closure Report for Corrective Action Unit 339: Area 12 Fleet Operations Steam Cleaning Discharge Area, Nevada Test Site, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Grant Evenson

    2009-05-01

    This document constitutes an addendum to the Closure Report for CAU 339: Area 12 Fleet Operations Steam Cleaning Discharge Area Nevada Test Site, December 1997 as described in the document Supplemental Investigation Report for FFACO Use Restrictions, Nevada Test Site, Nevada (SIR) dated November 2008. The SIR document was approved by NDEP on December 5, 2008. The approval of the SIR document constituted approval of each of the recommended UR removals. In conformance with the SIR document, this addendum consists of: • This page that refers the reader to the SIR document for additional information • The cover, title, and signature pages of the SIR document • The NDEP approval letter • The corresponding section of the SIR document This addendum provides the documentation justifying the cancellation of the UR for CAS 12-19-01, A12 Fleet Ops Steam Cleaning Efflu. This UR was established as part of a Federal Facility Agreement and Consent Order (FFACO) corrective action and is based on the presence of contaminants at concentrations greater than the action levels established at the time of the initial investigation (FFACO, 1996). Since this UR was established, practices and procedures relating to the implementation of risk-based corrective actions (RBCA) have changed. Therefore, this UR was reevaluated against the current RBCA criteria as defined in the Industrial Sites Project Establishment of Final Action Levels (NNSA/NSO, 2006). This re-evaluation consisted of comparing the original data (used to define the need for the UR) to risk-based final action levels (FALs) developed using the current Industrial Sites RBCA process. The re-evaluation resulted in a recommendation to remove the UR because contamination is not present at the site above the risk-based FALs. Requirements for inspecting and maintaining this UR will be canceled, and the postings and signage at this site will be removed. Fencing and posting may be present at this site that are unrelated to the

  6. An online Vce measurement and temperature estimation method for high power IGBT module in normal PWM operation

    DEFF Research Database (Denmark)

    Ghimire, Pramod; de Vega, Angel Ruiz; Beczkowski, Szymon

    2014-01-01

    An on-state collector-emitter voltage (Vce) measurement and thereby an estimation of average temperature in space for high power IGBT module is presented while power converter is in operation. The proposed measurement circuit is able to measure both high and low side IGBT and anti parallel diode...... voltages for a half bridge module which are also used to monitor the electrical degradation of the module. The Vce load current is proposed to estimate the variation of average temperature in space at every fundamental cycle of sinusoidal loading current. Initially, the calibration of voltage and junction...

  7. Discharge Dialogue

    DEFF Research Database (Denmark)

    Horsbøl, Anders

    2012-01-01

    less attention has been given to medical patients, who are often elderly and suffer from multiple diseases. This paper addresses the latter issue with a case study of a local initiative to improve transition from hospital to home (care) for medical patients at a Danish hospital, in which a discharge......For several years, efforts have been made to strengthen collaboration between health professionals with different specializations and to improve patient transition from hospital to home (care). In the Danish health care system, these efforts have concentrated on cancer and heart diseases, whereas...

  8. Signal sensing of the internal ducts inspection robot: GIRINO (Get Inside Robot to Impel Normal Operation); Sensoriamento de sinais do robo de inspecao interna de dutos: GIRINO (Gabarito Interno Robotizado de Incidencia Normal ao Oleoduto)

    Energy Technology Data Exchange (ETDEWEB)

    Panta, Pedro G.; Dutra, Max S. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE); Santos, Auderi V.; Ferreira, Rodrigo C. [Pontificia Univ. Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil). Centro de Estudos em Telecomunicacoes; Reis, Ney S. [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    2004-07-01

    One of the major challenges in the operation field of subway oil pipelines is the presence of blockades caused by paraffin and hydrates accumulation. The maintenance and inspection inside pipelines practiced until now imply complicated risky processes for people and equipment involved in daily operational activities. The Get Inside Robot to Impel Normal Operation (G.I.R.I.N.O.) is a robot developed by the Robotic Laboratory of PETROBRAS Research Center, that aims at looking for less risky ways in internal inspection process of pipelines which displacement movements are generated by hydraulic energy. In order to get the inspection and displacement functions, the G.I.R.I.N.O. needs a constant internal movement monitoring that is made by its several parts; the interaction with the environment in diverse processes. This paper has the objective of proposing a monitoring system for the 14 inch duct G.I.R.I.N.O. For this end, a study of available components for receiving , signal processing and visualization used in the industry that fulfill the basic requirements of the robot's performance was done. The choice of the proposed devices considers these main features: size, power consumption and marinization capability. (author)

  9. Status of achievements reached in applying optimization of protection in design and normal operation of nuclear facilities

    International Nuclear Information System (INIS)

    Lochard, J.; Croft, J.R.

    1988-01-01

    The increased emphasis in recent years on the ALARA principle and its practical implementation has opened new perspectives in the organisation of radiological protection. This change could be characterised as a shift from an 'a posteriori' control, (i.e. demonstrating that dose limits had not been exceeded), towards an 'a priori' management or dose predictive approach. Undoubtedly in both operation and design conscious efforts are made to achieve ALARA. However, there are certainly differences in various organisations' perceptions of what this practically entails and there is scope for us all to learn. If the 'ALARA Procedure' remains only a tool used at the early stage of design or as an elegant means of justifying past choices, it will have missed its main objective which is to give more rational and coherent management of practical protection at both the design and operational stages. We feel that the integration of the structured approaches of the ALARA Procedure and the ALARA Audit, into radiation protection programmes provides the best way forwad. This would require ALARA studies moving from the province of the 'experts' to the 'practitioners'. This in turn will require us to provide them with the tools to do the job. The methodology is secure but the areas of dose data collection and the costing of detriment need to be addressed further. Similarly, there is perhaps a need for the 'experts' to develop further experience of using the multiattribute and multicriteria techniques for the higher level decisions

  10. How can a change in the operating system of the mental health review board promote the discharge of long-term hospitalized psychiatric patients? A case study of Seoul city.

    Science.gov (United States)

    Lee, Myung-Soo; Lim, Hee-Young; Kim, Youngki; Lee, Yong-Suk

    2014-01-01

    One of the most typical and chronic problem in Korean mental health system is the prolonged length of hospital stay. In contrast to there are many components which leads to long length of stay of psychiatric patients in Korean situation such as low and fixed medical fee for psychiatric inpatient treatment, shortage of community resources, lack of care-givers' awareness and so on, there are just few mechanisms to handle this issue such as Mental Health Review Board (MHRB) which is based on Mental Health Act since 1995. However, the discharge order rate was very low and there community care system after discharge order is still very weak. The Korean government has revised the Mental Health Act in 2008 and changed the operating principals of the MHRB from a regional level to a local level to strengthen the function of MHRB. However, the discharge order rate versus the whole evaluation requests still remains at a very low level or less than 5%. And it is still very difficult to execute a discharge order against a patient whose symptoms and conditions become psychiatrically stabilized enough for discharge, due to a shortage of community care facilities and a lack of social support system. These results are exactly same with former studies. Any policies to promote psychiatric discharge including MHRB are needed to take the comprehensive factors into consideration, such as payment program, community infrastructure, increasing care-givers' acceptance and so on. Despite of the political trial of Korean government to reduce length of stay of chronic psychiatric patients, it was not successful. Still it had failed to propose a detailed policy measure in terms of the above-mentioned prerequisites. Therefore, new system and program developments including reform of payment system which reflect prior studies' recommendations are essential.

  11. Intra-operative on-line discrimination of kidney cancer from normal tissue by IR ATR spectroscopy of extracellular fluid

    Science.gov (United States)

    Urboniene, V.; Velicka, M.; Ceponkus, J.; Pucetaite, M.; Jankevicius, F.; Sablinskas, V.; Steiner, G.

    2016-03-01

    Determination of cancerous and normal kidney tissues during partial, simple or radical nephrectomy surgery was performed by using differences in the IR absorption spectra of extracellular fluid taken from the corresponding tissue areas. The samples were prepared by stamping of the kidney tissue on ATR diamond crystal. The spectral measurements were performed directly in the OR during surgery for 58 patients. It was found that intensities of characteristic spectral bands of glycogen (880-1200 cm-1) in extracellular fluid are sensitive to the type of the tissue and can be used as spectral markers of tumours. Characteristic spectral band of lactic acid (1730 cm-1) - product of the anaerobic glycolysis, taking place in the cancer cells is not suitable for use as a spectral marker of cancerous tissue, since it overlaps with the band of carbonyl stretch in phospholipids and fatty acids. Results of hierarchical cluster analysis of the spectra show that the spectra of healthy and tumour tissue films can be reliably separated into two groups. On the other hand, possibility to differentiate between tumours of different types and grades remains in question. While the fluid from highly malignant G3 tumour tissue contains highly pronounced glycogen spectral bands and can be well separated from benign and G1 tumours by principal component analysis, the variations between spectra from sample to sample prevent from obtaining conclusive results about the grouping between different tumour types and grades. The proposed method is instant and can be used in situ and even in vivo.

  12. A grid side converter current controller for accurate current injection under normal and fault ride through operation

    DEFF Research Database (Denmark)

    Hadjidemetriou, Lenos; Kyriakides, Elias; Blaabjerg, Frede

    2013-01-01

    requirements. In addition, the renewable energy systems require fault ride through capability in order to support the power grid under balanced or unbalanced low voltage grid faults. Therefore, the development of advanced current controller techniques is essential for the grid side power electronic converters...... in order to increase the renewable energy systems penetration and satisfy the grid codes. This paper proposes a current controller technique, which enables the appropriate operation of the grid side converter under unbalanced grid faults and harmonic distorted grid conditions. The proposed current...... controller is designed using multiple synchronous reference frames and can inject full positive or full negative sequence balanced sinusoidal currents under abnormal grid conditions. The accurate performance with robustness against unbalanced and harmonic distorted grid voltage indicates that the proposed...

  13. The effect of the operation modes of a gas discharge low-pressure amalgam lamp on the intensity of generation of 185 nm UV vacuum radiation

    Energy Technology Data Exchange (ETDEWEB)

    Vasilyak, L. M., E-mail: vasilyak@ihed.ras.ru [Russian Academy of Sciences, Joint Institute of High Temperatures (Russian Federation); Drozdov, L. A., E-mail: lit@npo.lit.ru; Kostyuchenko, S. V.; Sokolov, D. V. [ZAO LIT (Russian Federation); Kudryavtsev, N. N.; Sobur, D. A., E-mail: soburda@gmail.com [Moscow Institute for Physics and Technology (Russian Federation)

    2011-12-15

    The effect of the discharge current, mercury vapor pressure, and the inert gas pressure on the intensity and efficiency of the 185 nm line generation are considered. The spectra of the UV radiation (vacuum ultraviolet) transmission by protective coatings from the oxides of rare earth metals and aluminum are investigated.

  14. Environmental and economic assessment of discharges from Gulf of Mexico Region Oil and Gas Operations. Quarterly technical progress report, January 1, 1994--March 31, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Gettleson, D.A.

    1994-04-21

    The primary objectives of the project are to increase the base of scientific knowledge concerning (1) the fate and environmental effects of organics, trace metals, and NORM in water, sediment, and biota near several offshore oil and gas facilities; (2) the characteristics of produced water and produced sand discharges as they pertain to organics, trace metals, and NORM variably found in association with the discharges; (3) the recovery of four terminated produced water discharge sites located in wetland and high-energy open bay sites of coastal Louisiana and Texas; (4) the economic and energy supply impacts of existing and anticipated federal and state offshore and coastal discharge regulations; and (5) the catch, consumption and human use patterns of seafood species collected from coastal and offshore waters. The products of the effort will be a series of technical reports detailing the study procedures, results, and conclusions which contribute to the transfer of technology to the scientific community, petroleum industry, and state and federal programs.

  15. Potential for normally-off operation from GaN metal oxide semiconductor devices based upon semi-insulating GaN

    Directory of Open Access Journals (Sweden)

    Yusuke Sakai

    2013-08-01

    Full Text Available The conditions for preparing normally-off GaN devices incorporating semi-insulating (SI GaN materials are explored. The properties of SI GaN where carbon behaves as a deep level acceptor are predicted using a Shockley diagram. Metal-oxide-semiconductor (MOS structures based upon these on SI-GaN layers are designed. The bandgap alignment of these structures is analyzed using Poisson equations. Normally-off operation is shown to be possible in devices featuring a thin n-GaN layer and SI-GaN layer, because of a higher conduction band energy. It is also shown that higher threshold voltage can be achieved by reducing the carrier concentration of the n-GaN channel layer.

  16. Sensitivity Analysis of Input Parameters for the Dose Assessment from Gaseous Effluents due to the Normal Operation of Jordan Research and Training Reactor

    International Nuclear Information System (INIS)

    Kim, Sukhoon; Lee, Seunghee; Kim, Juyoul; Kim, Juyub; Han, Moonhee

    2015-01-01

    In this study, therefore, the sensitivity analysis of input variables for the dose assessment was performed for reviewing the effect of each parameter on the result after determining the type and range of parameters that could affect the exposure dose of the public. (Since JRTR will be operated by the concept of 'no liquid discharge,' the input parameters used for calculation of dose due to liquid effluents are not considered in the sensitivity analysis.) In this paper, the sensitivity analysis of input parameters for the dose assessment in the vicinity of the site boundary due to gaseous effluents was performed for a total of thirty-five (35) cases. And, detailed results for the input variables that have an significant effect are shown in Figures 1 through 7, respectively. For preparing a R-ER for the operating license of the JRTR, these results will be updated by the additional information and could be applied to predicting the variation trend of the exposure dose in the process of updating the input parameters for the dose assessment reflecting the characteristics of the JRTR site

  17. Lung surgery - discharge

    Science.gov (United States)

    ... Lung biopsy - discharge; Thoracoscopy - discharge; Video-assisted thoracoscopic surgery - discharge; VATS - discharge ... milk) for 2 weeks after video-assisted thoracoscopic surgery and 6 to 8 weeks after open surgery. ...

  18. Hysterectomy - vaginal - discharge

    Science.gov (United States)

    Vaginal hysterectomy - discharge; Laparoscopically assisted vaginal hysterectomy - discharge; LAVH - discharge ... you are unable to urinate. You have a discharge from your vagina that has a bad odor. You have bleeding ...

  19. Pediatric heart surgery - discharge

    Science.gov (United States)

    ... discharge; Heart valve surgery - children - discharge; Heart surgery - pediatric - discharge; Heart transplant - pediatric - discharge ... Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ed. Philadelphia, PA: Elsevier; 2016:chap 434. ...

  20. Hip replacement - discharge

    Science.gov (United States)

    ... discharge; Total hip replacement - discharge; Hip hemiarthroplasty - discharge; Osteoarthritis - hip replacement discharge ... such as downhill skiing or contact sports like football and soccer. But you should be able to ...

  1. Suspended particle and pathogen peak discharge buffering by a surface-flow constructed wetland

    NARCIS (Netherlands)

    Mulling, B.T.M.; van den Boomen, R.M.; van der Geest, H.G.; Kappelhof, J.W.N.M.; Admiraal, W.

    2013-01-01

    Constructed wetlands (CWs) have been shown to improve the water quality of treated wastewater. The capacity of CWs to reduce nutrients, pathogens and organic matter and restore oxygen regime under normal operating conditions cannot be extrapolated to periods of incidental peak discharges. The

  2. High pressure discharges in cavities formed by microfabrication techniques

    International Nuclear Information System (INIS)

    Khan, B.A.; Cammack, D.A.; Pinker, R.D.; Racz, J.

    1997-01-01

    High pressure discharges are the basis of small high intensity light sources. In this work, we demonstrate the formation of high pressure discharges, in cavities formed by applying micromachining and integrated circuit techniques to quartz substrates. Cavities containing varying amounts of mercury and argon were fabricated to obtain high pressure discharges. A high pressure mercury discharge was formed in the electrodeless cavities by exciting them with a microwave source, operating at 2.45 GHz and in the electroded cavities by applying a dc voltage. The contraction of the discharge into a high pressure arc was observed. A broad emission spectrum due to self-absorption and collisions between excited atoms and normal atoms, typical of high pressure mercury discharges, was measured. The light output and efficacy increased with increasing pressure. The measured voltage was used to estimate the pressure within the electroded cavities, which is as high as 127 atm for one of the two cavities discussed in this work. Efficacies over 40 lumens per watt were obtained for the electrodeless cavities and over 50 scr(l)m/W for the electroded cavities. copyright 1997 American Institute of Physics

  3. Septoplasty - discharge

    Science.gov (United States)

    ... before taking it. You should not drive, operate machinery, drink alcohol, or make any major decisions for ... breath, and tightening muscles during bowel movements. Avoid heavy lifting and hard physical activity for 1 to ...

  4. A comparative study of changes operated by sympathetic nervous system activation on spindle afferent discharge and on tonic vibration reflex in rabbit jaw muscles.

    Science.gov (United States)

    Passatore, M; Deriu, F; Grassi, C; Roatta, S

    1996-03-07

    The effect of sympathetic activation on the spindle afferent response to vibratory stimuli eliciting the tonic vibration reflex in jaw closing muscles was studied in precollicularly decerebrate rabbits. Stimulation of the cervical sympathetic trunk, at frequencies within the physiologic range, consistently induced a decrease in spindle response to muscle vibration, which was often preceded by a transient enhancement. Spindle discharge was usually correlated with the EMG activity in the masseter muscle and the tension reflexly developed by jaw muscles. The changes in spindle response to vibration were superimposed on variations of the basal discharge which exhibited different patterns in the studied units, increases in the firing rate being more frequently observed. These effects were mimicked by close arterial injection of the selective alpha 1-adrenoceptor agonist phenylephrine. Data presented here suggest that sympathetically-induced modifications of the tonic vibration reflex are due to changes exerted on muscle spindle afferent information.

  5. Microwave Photocatalysis IV: Effects of Additional Operational Parameters on the Microwave Photocatalytic Degradation of Mono-Chloroacetic Acid Using Titania-Coated Mercury Electrodeless Discharge Lamps

    Czech Academy of Sciences Publication Activity Database

    Kmentová, Hana; Církva, Vladimír

    2013-01-01

    Roč. 88, č. 6 (2013), s. 1109-1113 ISSN 0268-2575 R&D Projects: GA ČR GA104/07/1212; GA ČR GD203/08/H032 Institutional support: RVO:67985858 Keywords : microwave photocatalysis * titania thin film * mercury electrodeless discharge lamp Subject RIV: CH - Nuclear ; Quantum Chemistry Impact factor: 2.494, year: 2013

  6. Real time control of fully non-inductive operation in Tore Supra leading to 6 minutes, 1 giga-joule plasma discharges

    International Nuclear Information System (INIS)

    Van Houtte, D.; Martin, G.; Becoulet, A.; Saoutic, B.

    2004-01-01

    The experimental programme of Tore Supra (a = 0.72 m, R = 2.4 m, I p T < 4.5 T) has been devoted in 2003 to study simultaneously heat removal capability and particle exhaust in steady-state fully non-inductive current drive discharges. This required both advanced technology integration and steady-state real time plasma control. In particular, an improvement of the plasma position within a few millimetre range, and new real time cross controls between radio frequency (RF) power and various actuators built around a shared memory network, have allowed Tore Supra to access a powerful steady-state regime with an improved safety level for the actively cooled plasma facing components. Feedback controlled fully non-inductive plasma discharges have been sustained in a steady-state regime up to 6 minutes with a new world record of injected-extracted energy exceeding 1 GJ. Advanced tools, experimental results and brief physics analysis of these discharges are presented and discussed. (authors)

  7. Range of the radiation monitor for the rigid vent of primary containment during normal and emergency operation for a BWR-5 in Laguna Verde

    International Nuclear Information System (INIS)

    Tijerina S, F.; Pozos S, A. M.; Cabrera U, S.; Mata A, J. A.; Sandoval V, S.; Ovando C, R.; Vargas A, A.; Gallardo R, I.; Cruz G, M.; Amador C, C.

    2014-10-01

    The earthquake followed by a tsunami, happened in March, 2011 in the coasts of oriental Japan, caused damages in the nuclear power plants 1 at 4 of Fukushima Daiichi leading to damage of the fuel in three of the reactors and to the radiation liberation to the exterior. As consequence of those events, the regulations requires that the power plants with Primary Containment type Mark I and II evaluate to have a system of rigid vent with a monitoring equipment of radiation effluents. The present work covers the rigid vent of diameter 12 of the Primary Containment, type Mark-II, of nuclear power plant of Laguna Verde in conditions of severe accident and normal operation, low regime of Extended Power Up rate (EPU - 2317 MWt), using the codes MAAP3B, MICROSHILED 5.05 and the Bardach Black Boxes methodology. As a result the measurement range of the radiation monitor that is required for monitoring the gassy liberation to the atmosphere was determined. The conclusion is that the superior limit of the range of the radiation meter during a Severe Accident is of 8.55 E + 05 R/h (8.55 E + 08 m R/h) and the superior limit in normal operation of 1.412 E-11 at 2.540 E-7 R/h (1.412 E-14 at 2.540 E-10 m R/h). (Author)

  8. Is there a correlation between operative results and change in ventricular volume after shunt placement? A study of 60 cases of idiopathic normal-pressure hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Meier, U.; Graewe, A.; Hajdukova, A. [Department of Neurosurgery, Unfallkrankenhaus Berlin, Warener Strasse 7, 12683, Berlin (Germany); Paris, S.; Stockheim, D.; Mutze, S. [Department of Radiology, Unfallkrankenhaus Berlin, Warener Strasse 7, 12683, Berlin (Germany)

    2003-06-01

    In patients with communicating or normal-pressure hydrocephalus, ventricular volume decreases following implantation of differential pressure valves. We implanted hydrostatic (Miethke dual-switch) valves in 60 patients with normal-pressure hydrocephalus (NPH) between September 1997 and December 2001. The patients underwent CT 1 year after operation, and we measured the Evans index. Although 83% of the patients showed no change in ventricular volume as assessed by this index, 72% nevertheless showed good to excellent and 16% satisfactory clinical improvement, while 12% showed no improvement. Moderate or marked reduction in ventricular size was observed in 17%, of whom 40% of these patients showed good to excellent and 20% satisfactory clinical improvement; 40% showed unsatisfactory improvement. The favourable outcome following implantation of a hydrostatic shunt thus did not correlate with decreased ventricular volume 1 year after operation, better outcomes being observed in patients with little or no alteration in ventricular size than in those with a marked decrease. Postoperative change in ventricular volume in NPH thus does not have the same significance as in patients with high-pressure hydrocephalus. (orig.)

  9. Proceedings of the technical committee meeting on sodium removal and disposal from LMFRs in normal operation and in the framework of decommissioning

    International Nuclear Information System (INIS)

    Latge, C.

    1997-11-01

    This publication summarizes discussions and presented papers from the Technical Committee meeting on sodium removal and disposal from liquid metal fast reactors in normal operation and in the framework of decommissioning, organised by IAEA. The objective of this meeting was to provide a forum to review and exchange information on the international developments in technologies of sodium removal and disposal from liquid metal fast reactor components and systems in operation and maintenance conditions, and in framework of decommissioning. The technical parts of the meeting covered the three major subjects: sodium removal (cleaning) process, decontamination process and bulk disposal of sodium in the framework of decommissioning. These technologies were reviewed with regard to their implementation into current plants to improve operation and maintenance, and to develop an effective decommissioning program. Further, design for future Liquid metal fast reactors were reviewed in the context how they can accommodate today's technologies. The meeting resulted in an effective information exchange with the Member States sharing their needs as well as experiences in the mentioned topics

  10. Lifetime analysis of the ITER first wall under steady-state and off-normal loads

    International Nuclear Information System (INIS)

    Mitteau, R; Sugihara, M; Raffray, R; Carpentier-Chouchana, S; Merola, M; Pitts, R A; Labidi, H; Stangeby, P

    2011-01-01

    The lifetime of the beryllium armor of the ITER first wall is evaluated for normal and off-normal operation. For the individual events considered, the lifetime spans between 930 and 35×10 6 discharges. The discrepancy between low and high estimates is caused by uncertainties about the behavior of the melt layer during off-normal events, variable plasma operation parameters and variability of the sputtering yields. These large uncertainties in beryllium armor loss estimates are a good example of the experimental nature of the ITER project and will not be truly resolved until ITER begins burning plasma operation.

  11. Intra-operative Vector Flow Imaging Using Ultrasound of the Ascending Aorta among 40 Patients with Normal, Stenotic and Replaced Aortic Valves

    DEFF Research Database (Denmark)

    Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse; Kjaergaard, Jesper

    2016-01-01

    Stenosis of the aortic valve gives rise to more complex blood flows with increased velocities. The angleindependent vector flow ultrasound technique transverse oscillation was employed intra-operatively on the ascending aorta of (I) 20 patients with a healthy aortic valve and 20 patients with aor...... replacement corrects some of these changes. Transverse oscillation may be useful for assessment of aortic stenosis and optimization of valve surgery. (E-mail: lindskov@gmail.com) 2016 World Federation for Ultrasound in Medicine & Biology...... with aortic stenosis before (IIa) and after (IIb) valve replacement. The results indicate that aortic stenosis increased flow complexity (p , 0.0001), induced systolic backflow (p , 0.003) and reduced systolic jet width (p , 0.0001). After valve replacement, the systolic backflow and jet width were normalized...

  12. Description of NORMTRI: a computer program for assessing the off-site consequences from air-borne releases of tritium during normal operation of nuclear facilities

    International Nuclear Information System (INIS)

    Raskob, W.

    1994-10-01

    The computer program NORMTRI has been developed to calculate the behaviour of tritium in the environment released into the atmosphere under normal operation of nuclear facilities. It is possible to investigate the two chemical forms tritium gas and tritiated water vapour. The conversion of tritium gas into tritiated water followed by its reemission back to the atmosphere as well as the conversion into organically bound tritium is considered. NORMTRI is based on the statistical Gaussian dispersion model ISOLA, which calculates the activity concentration in air near the ground contamination due to dry and wet deposition at specified locations in a polar grid system. ISOLA requires a four-parametric meteorological statistics derived from one or more years synoptic recordings of 1-hour-averages of wind speed, wind direction, stability class and precipitation intensity. Additional features of NORMTRI are the possibility to choose several dose calculation procedures, ranging from the equations of the German regulatory guidelines to a pure specific equilibrium approach. (orig.)

  13. Ankle replacement - discharge

    Science.gov (United States)

    ... total - discharge; Total ankle arthroplasty - discharge; Endoprosthetic ankle replacement - discharge; Osteoarthritis - ankle ... You had an ankle replacement. Your surgeon removed and reshaped ... an artificial ankle joint. You received pain medicine and were ...

  14. Tennis elbow surgery - discharge

    Science.gov (United States)

    Lateral epicondylitis surgery - discharge; Lateral tendinosis surgery - discharge; Lateral tennis elbow surgery - discharge ... Soon after surgery, severe pain will decrease, but you may have mild soreness for 3 to 6 months.

  15. Knee joint replacement - discharge

    Science.gov (United States)

    ... Knee replacement - total - discharge; Tricompartmental knee replacement - discharge; Osteoarthritis - knee replacement discharge ... such as downhill skiing or contact sports like football and soccer. But, you should be able to ...

  16. Microwave discharges in capillary tubes

    International Nuclear Information System (INIS)

    Dervisevic, Emil

    1984-01-01

    This research thesis aims at being a contribution to the study of microwave discharge by a surface wave, and more precisely focusses on the discharge in capillary tubes filled with argon. The author first present theoretical models which describe, on the one hand, the propagation of the surface wave along the plasma column, and, on the other hand, longitudinal and radial profiles of the main discharge characteristics. The second part addresses the study of the influence of parameters (gas pressure and tube radius) on discharge operation and characteristics. Laws of similitude as well as empirical relationships between argon I and argon II emission line intensities, electron density, and electric field in the plasma have been established [fr

  17. Discharge processes of UV pre-ionized electric-discharge pulsed DF laser

    Science.gov (United States)

    Pan, Qikun; Xie, Jijiang; Shao, Chunlei; Wang, Chunrui; Shao, Mingzhen; Guo, Jin

    2016-03-01

    The discharge processes of ultraviolet (UV) pre-ionized electric-discharge pulsed DF laser operating with a SF6-D2 gas mixture are studied. A mathematical model based on continuity equation of electrons and Kirchhoff equations for discharge circuit is established to describe the discharge processes. Voltage and current waveforms of main discharge and voltage waveforms of pre-ionization are solved numerically utilizing the model. The calculations correctly display some physical processes, such as the delay time between pre-ionization and main discharge, breakdown of the main electrode and self-sustained volume discharge (SSVD). The results of theory are consistent with the experiments, which are performed in our non-chain pulsed DF laser. Then the delay inductance and peak capacitance are researched to analyze their influences on discharge processes, and the circuit parameters of DF laser are given which is useful to improve the discharge stability.

  18. Calibration of a PHREEQC-based geochemical model to predict surface water discharge from an operating uranium mill in the Athabasca Basin

    International Nuclear Information System (INIS)

    Mahoney, J.; Ryan, F.

    2014-01-01

    A PHREEQC based geochemical model has been developed to predict impacts from the McClean Lake Mill discharges through three lakes in the Athabasca Basin, Saskatchewan, Canada. The model is primarily a mixing calculation that uses site specific water balances and water compositions from five sources: 1) two water treatment plants, 2) waters from pit dewatering wells, 3) run-off into the lakes from surface waters, 4) ambient lake compositions, and 5) precipitation (rain and snow) onto the pit lake surface. The model allows for the discharge of these waters into the first lake, which then flows into another nearby lake and finally into a third larger lake. Water losses through evaporation and the impact of subsequent evapoconcentration processes are included in the model. PHREEQC has numerous mass transfer options including mixing, user specified reactions, equilibration with gas and solid phases, and surface complexation. Thus this program is ideally suited to this application. Preparation of such a complicated model is facilitated by an EXCEL Spreadsheet, which converts the water balance into appropriately formatted mixing proportions and to prepare portions of the PHREEQC input file in a format directly useable by PHREEQC. This allows for a high level of flexibility, while reducing transcription errors. For each scenario, the model path involves mixing of the waters in the first lake, followed by evapoconcentration, equilibration of the resulting solution with gas phases, including carbon dioxide and oxygen and with minerals and surfaces. The resultant composition is mixed in the second lake with more surface water, lake water and precipitation, and then re-equilibrated. This water represents the flow into the final lake; further mixing/dilution is accommodated; chemical equilibration may also occur. Because of the numerous steps and processes that define the pathway, each annual step requires approximately 200 lines of input in PHREEQC. Models used in the initial

  19. Review of construction criteria for nuclear fuels under normal operation and anticipated operational occurrences - a literature study; Oeversyn av konstruktionskriterier foer kaernbraensle under normaldrift och foervaentade driftsstoerningar - en litteraturstudie

    Energy Technology Data Exchange (ETDEWEB)

    Rudling, P. [Advanced Nuclear Technology, Uppsala (Sweden)

    1999-06-01

    General Design Criteria 10, GDC 10, in the Code of Federal Regulation Part 50 of Nuclear Regulatory Commission specifies that the fuel assembly including the fuel rod may not be damaged during normal operation and anticipated operational occurrences. No damaged, means that the fuel rods do not fail, that fuel rod and assembly dimensions remain within operational tolerances, and that functional capabilities are not reduced below those assumed in the safety analysis. This objective is given by GDC 10, and the design limits that are required to accomplish this objective are called Specified Acceptable Fuel Design Limits, SAFDLs. The SAFDLs are specified in Standard Review Plan, SRP, chapter 4.2. This report summarises and analyses published open data that are relevant for the below-specified SAFDLs. It also summarises the current view of NRC on the discussed SAFDLs as well as the margin towards fuel failure of the SAFDLs. The following SAFDLs are discussed herein: Avoidance of fuel centre melting; Avoidance of liftoff; Maximum cladding creep deformation; Avoidance of cladding collapse; Maximum fretting; Maximum dimensional changes; Maximum stresses; Maximum fatigue stresses; Maximum oxide thickness; Maximum hydrogen content; Avoidance of PCI - failures.

  20. Charge/discharge performance of lithium-ion secondary cells under microgravity conditions: Lessons learned from operation of interplanetary spacecraft Hayabusa

    International Nuclear Information System (INIS)

    Sone, Yoshitsugu

    2013-01-01

    The Japan Aerospace Exploration Agency (JAXA) is developing a lithium-ion secondary battery for deep space missions. Lithium-ion secondary battery was first used for the interplanetary spacecraft, Hayabusa. With a view to future long-term operations on the moon and interplanetary travel, the in-orbit performance of the lithium-ion battery of Hayabusa was examined. The battery cells maintained a constant performance over 2.7 years of operation as Hayabusa travelled to the asteroid Itokawa. To maintain cell conditions. The state of charge was fixed by using a balance circuit. The cell voltages differed by less than 60 mV during the operation, which is within the error expected based on the circuit design and the telemetry conditions

  1. Comparison of the Tritium permeated from ITER Blanket in normal operation and its short range impact of HT over France, Swiss or Spain

    Energy Technology Data Exchange (ETDEWEB)

    Castro, P.; Velarde, M.; Ardao, J.; Perlado, J.; Sedano, L.; Xiberta, J.

    2015-07-01

    In this paper we assumes the hydrogen isotopes permeation from a liquid metal ITER breeder blanket (assuming normal operation and a LM as DCLL or HCLL blanket) as one of the possible sources of a leak and tritium release,mainly but not only. The paper presents a short range low impact of HT gas activity over France, Swiss or Spain from same cases in 2014 and 2015 releases from ITER. The permeation of hydrogen isotopes is an important experimental issue to take into account into the development of a Tritium Breeder Module for ITER [1]. Tritium cannot be confined -without an uncertainty of 5% in the flux permeation- and therefore HT can be detected (e.g. by ionization chamber) as permeates though the structure of RAFM steel towards the coolant [1]. HT from Pb15.7Li and permeated in Eurofer97 can contaminate the other parts of the system and may be delivered though the normal-vent detritiation system (NVDS). Real time forecast of transport of tritium in air from the fusion reactor towards off-site far downwind though extended tritium clouds into the low levels of the atmosphere is calculated for the short range (up to 24 hours) by the coupling of 2 models the European Centre for Medium Range Weather Forecast (ECMWF) [2] model and the FLEXPART lagrangian dispersion model [3] verified with NORMTRI simulation [4] and implemented in many different cases and scenarios [5, 6, 7]. As a function of daily weather conditions the release will affect just France or already can be delivered towards Swiss when cyclonic circulation, or towards the Iberian Peninsula or Balearic Islands (Spain) when high produce anticyclonic circulation of the air over the Mediterranean Sea. (Author)

  2. Readiness for hospital discharge: A concept analysis.

    Science.gov (United States)

    Galvin, Eileen Catherine; Wills, Teresa; Coffey, Alice

    2017-11-01

    To report on an analysis on the concept of 'readiness for hospital discharge'. No uniform operational definition of 'readiness for hospital discharge' exists in the literature; therefore, a concept analysis is required to clarify the concept and identify an up-to-date understanding of readiness for hospital discharge. Clarity of the concept will identify all uses of the concept; provide conceptual clarity, an operational definition and direction for further research. Literature review and concept analysis. A review of literature was conducted in 2016. Databases searched were: Academic Search Complete, CINAHL Plus with Full Text, PsycARTICLES, Psychology and Behavioural Sciences Collection, PsycINFO, Social Sciences Full Text (H.W. Wilson) and SocINDEX with Full Text. No date limits were applied. Identification of the attributes, antecedents and consequences of readiness for hospital discharge led to an operational definition of the concept. The following attributes belonging to 'readiness for hospital discharge' were extracted from the literature: physical stability, adequate support, psychological ability, and adequate information and knowledge. This analysis contributes to the advancement of knowledge in the area of hospital discharge, by proposing an operational definition of readiness for hospital discharge, derived from the literature. A better understanding of the phenomenon will assist healthcare professionals to recognize, measure and implement interventions where necessary, to ensure patients are ready for hospital discharge and assist in the advancement of knowledge for all professionals involved in patient discharge from hospital. © 2017 John Wiley & Sons Ltd.

  3. Expansion of a nitrogen discharge by sound

    International Nuclear Information System (INIS)

    Antinyan, M.A.; Galechyan, G.A.; Tavakalyan, L.B.

    1992-01-01

    When the background pressure and the discharge current in a gas discharge are raised the plasma column is tightened up into a filament. Then the discharge occupies a region of the discharge tube whose transverse dimensions are substantially less than those of the tube. This contraction phenomenon in discharges restricts the range of parameters used in various devices to the range of relatively low discharge currents and low gas pressures. This contraction interferes with creating high-power gas lasers, since it acts destructively on the lasing process. In order to suppress filamentation of discharges the working gas has been pumped through the system at high speed, with considerable success. The turbulent mixing in the stream plays an important role in creating an uncontracted discharge at high pressures. The purpose of the present work is to study the possibility of undoing the contraction of a nitrogen discharge, which is one of the main components in the operation of a CO 2 laser, by introducing an intense sound wave in the discharge tube. Discharge contraction and the effect of a sound wave propagating along the plasma column have been investigated experimentally in nitrogen by studying the current-voltage characteristics of a contracted discharge. 6 refs., 3 figs

  4. The vapor-phase multi-stage CMD test for characterizing contaminant mass discharge associated with VOC sources in the vadose zone: Application to three sites in different lifecycle stages of SVE operations.

    Science.gov (United States)

    Brusseau, M L; Mainhagu, J; Morrison, C; Carroll, K C

    2015-08-01

    Vapor-phase multi-stage contaminant mass discharge (CMD) tests were conducted at three field sites to measure mass discharge associated with contaminant sources located in the vadose zone. The three sites represent the three primary stages of the soil vapor extraction (SVE) operations lifecycle-pre/initial-SVE, mid-lifecycle, and near-closure. A CMD of 32g/d was obtained for a site at which soil vapor SVE has been in operation for approximately 6years, and for which mass removal is currently in the asymptotic stage. The contaminant removal behavior exhibited for the vapor extractions conducted at this site suggests that there is unlikely to be a significant mass of non-vapor-phase contaminant (e.g., DNAPL, sorbed phase) remaining in the advective domains, and that most remaining mass is likely located in poorly accessible domains. Given the conditions for this site, this remaining mass is hypothesized to be associated with the low-permeability (and higher water saturation) region in the vicinity of the saturated zone and capillary fringe. A CMD of 25g/d was obtained for a site wherein SVE has been in operation for several years but concentrations and mass-removal rates are still relatively high. A CMD of 270g/d was obtained for a site for which there were no prior SVE operations. The behavior exhibited for the vapor extractions conducted at this site suggest that non-vapor-phase contaminant mass (e.g., DNAPL) may be present in the advective domains. Hence, the asymptotic conditions observed for this site most likely derive from a combination of rate-limited mass transfer from DNAPL (and sorbed) phases present in the advective domain as well as mass residing in lower-permeability ("non-advective") regions. The CMD values obtained from the tests were used in conjunction with a recently developed vapor-discharge tool to evaluate the impact of the measured CMDs on groundwater quality. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Influence of condition of vacuum chamber wall upon discharge parameters in the Tuman-2a tokamak

    International Nuclear Information System (INIS)

    Gladushchak, B.I.; Gusev, V.K.; Ipatov, V.A.; Kalmykov, S.G.; Lashkul, S.I.; Rozhdestvenskij, V.V.; Petrov, Yu.V.; Shprits, I.D.

    1983-01-01

    The condition of the inner surface of vacuum chamber walls in tokamaks strongly depends on the surface cleaning methods used. After introducing a gas-discharge cleaning in the Tuman-2a tokamak, a clean discharge, characterized by a low content of impurities, low effective ion charge number (Z=1-1.2), and prevailing losses of the transport type, has been achieved. Unfortunately, the cleaning discharges proved to be a source of ferromagnetic metallic dust well absorbing hydrogen. Over several years of operation the accumulation of metallic dust made it necessary to discontinue further experiments with magnetic compression. Normal experimental conditions were restored only after the whole vacuum chamber had been mechanically cleaned. As ion sputtering increases proportionally to the ion mass, cleaning discharges with noble gases of higher ion mass should be avoided in tokamaks. (J.U.)

  6. Electromagnetic fields produced by simulated spacecraft discharges

    Science.gov (United States)

    Nonevicz, J. E.; Adamo, R. C.; Beers, B. L.; Delmer, T. N.

    1980-01-01

    The initial phase of a broader, more complete program for the characterization of electrical breakdowns on spacecraft insulating materials is described which consisted of the development of a discharge simulator and characterization facility and the performance of a limited number of discharge measurements to verify the operation of the laboratory setup and to provide preliminary discharge transient field data. A preliminary model of the electromagnetic characteristics of the discharge was developed. It is based upon the "blow off" current model of discharges, with the underlying assumption of a propagating discharge. The laboratory test facility and discharge characterization instrumentation are discussed and the general results of the "quick look" tests are described on quartz solar reflectors aluminized Kapton and silver coated Teflon are described.

  7. Development of Partial Discharging Simulation Test Equipment

    Science.gov (United States)

    Kai, Xue; Genghua, Liu; Yan, Jia; Ziqi, Chai; Jian, Lu

    2017-12-01

    In the case of partial discharge training for recruits who lack of on-site work experience, the risk of physical shock and damage of the test equipment may be due to the limited skill level and improper operation by new recruits. Partial discharge simulation tester is the use of simulation technology to achieve partial discharge test process simulation, relatively true reproduction of the local discharge process and results, so that the operator in the classroom will be able to get familiar with and understand the use of the test process and equipment.The teacher sets up the instrument to display different partial discharge waveforms so that the trainees can analyze the test results of different partial discharge types.

  8. Public member dose assessment of Bushehr Nuclear Power Plant under normal operation by modeling the fallout from stack using the HYSPLIT atmospheric dispersion model.

    Science.gov (United States)

    Zali, A; Shamsaei Zafarghandi, M; Feghhi, S A; Taherian, A M

    2017-05-01

    In this work, public dose resulting from fission products released from Bushehr Nuclear Power Plant (BNPP) under normal operation is assessed. Due to the long range transport of radionuclides in this work (80 km) and considering terrain and meteorological data, HYbrid Single-Particle Lagrangian Integrated Trajectory (HYsplit) model, which uses three dimensional long-range numerical models, has been employed to calculate atmospheric dispersion. Annual effective dose calculation is carried out for inhalation, ingestion, and external exposure pathways in 16directions and within 80 km around the site for representative person. The results showed the maximum dose of inhalation and external exposure for adults is 3.8 × 10 -8 Sv/y in the SE direction and distance of 600 m from the BNPP site which is less than ICRP 103 recommended dose limit (1 mSv). Children and infants' doses are higher in comparison with adults, although they are less than 1 mSv. Ingestion dose percentage in the total dose is less than 0.1%. The results of this study underestimate the Final Safety Analysis Report ofBNPP-1 (FSAR)data. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Analysis of the thermo-mechanical behaviour of the DEMO Water-Cooled Lithium Lead breeding blanket module under normal operation steady state conditions

    Energy Technology Data Exchange (ETDEWEB)

    Di Maio, P.A.; Arena, P. [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo, Viale delle Scienze, 90128 Palermo (Italy); Aubert, J. [CEA Saclay, DEN/DANS/DM2S/SEMT, 91191 Gif sur Yvette Cedex (France); Bongiovì, G. [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo, Viale delle Scienze, 90128 Palermo (Italy); Chiovaro, P., E-mail: pierluigi.chiovaro@unipa.it [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo, Viale delle Scienze, 90128 Palermo (Italy); Giammusso, R. [ENEA – C.R. Brasimone, 40032 Camugnano (Italy); Li Puma, A. [CEA Saclay, DEN/DANS/DM2S/SEMT, 91191 Gif sur Yvette Cedex (France); Tincani, A. [ENEA – C.R. Brasimone, 40032 Camugnano (Italy)

    2015-10-15

    Highlights: • A DEMO WCLL blanket module thermo-mechanical behaviour has been investigated. • Two models of the WCLL blanket module have been set-up adopting a code based on FEM. • The water flow domain in the module has been considered. • A set of uncoupled steady state thermo-mechanical analyses has been carried out. • Critical temperature is not overcome. Safety verifications are generally satisfied. - Abstract: Within the framework of DEMO R&D activities, a research cooperation has been launched between ENEA, the University of Palermo and CEA to investigate the thermo-mechanical behaviour of the outboard equatorial module of the DEMO1 Water-Cooled Lithium Lead (WCLL) blanket under normal operation steady state scenario. The research campaign has been carried out following a theoretical–computational approach based on the Finite Element Method (FEM) and adopting a qualified commercial FEM code. In particular, two different 3D FEM models (Model 1 and Model 2), reproducing respectively the central and the lateral poloidal–radial slices of the WCLL blanket module, have been set up. A particular attention has been paid to the modelling of water flow domain, within both the segment box channels and the breeder zone tubes, to simulate realistically the coolant-box thermal coupling. Results obtained are herewith reported and critically discussed.

  10. Behavior of U3Si2 Fuel and FeCrAl Cladding under Normal Operating and Accident Reactor Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Gamble, Kyle Allan Lawrence [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hales, Jason Dean [Idaho National Lab. (INL), Idaho Falls, ID (United States); Barani, Tommaso [Idaho National Lab. (INL), Idaho Falls, ID (United States); Pizzocri, Davide [Idaho National Lab. (INL), Idaho Falls, ID (United States); Pastore, Giovanni [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-09-01

    As part of the Department of Energy's Nuclear Energy Advanced Modeling and Simulation program, an Accident Tolerant Fuel High Impact Problem was initiated at the beginning of fiscal year 2015 to investigate the behavior of \\usi~fuel and iron-chromium-aluminum (FeCrAl) claddings under normal operating and accident reactor conditions. The High Impact Problem was created in response to the United States Department of Energy's renewed interest in accident tolerant materials after the events that occurred at the Fukushima Daiichi Nuclear Power Plant in 2011. The High Impact Problem is a multinational laboratory and university collaborative research effort between Idaho National Laboratory, Los Alamos National Laboratory, Argonne National Laboratory, and the University of Tennessee, Knoxville. This report primarily focuses on the engineering scale research in fiscal year 2016 with brief summaries of the lower length scale developments in the areas of density functional theory, cluster dynamics, rate theory, and phase field being presented.

  11. Assessment of radiation dose caused by radioactive gaseous effluent released from nuclear power plant Ninh Thuan 1 under scenario of normal operation

    International Nuclear Information System (INIS)

    Do Xuan Anh; Le Dinh Cuong; Duong Duc Thang; Vuong Thu Bac; Nguyen Thi Thu Ha; Nguyen Quang Long; Trinh Van Giap; Nguyen Tuan Khai; Nguyen Hao Quang

    2014-01-01

    Based on guides RG 1.109, RG 1.111 published by United States Nuclear Regulatory Commission (USNRC) our research concentrates in assessing radiation doses caused by radioactive substances released from the nuclear power plant (NPP) Ninh Thuan 1 under the scenario of normal operation using software package NRCDose72 provided by the USNRC. The database including the released radioactive nuclides, meteorology, terrain, population and agricultural production activities have been collected and processed to build the input data for the model calculation. The wind rose distribution obtained from the meteorological data in a five-year period from 2009-2013 showed that the radioactive nuclides released to environment spread in two main wind directions which are North East and South West. The X/Q (s/m 3 ) and D/Q (s/m 2 ) qualities which are, respectively, the ratio of activity concentration to release rate and that of deposition density of radioactive nuclides to release rate were calculated within an area of 80 km radius from the NPP site using XOQDOQ. Population doses were calculated using GASPAR. The XOQDOQ and GASPAR are two specific softwares in NRCDose72 package. (author)

  12. Echinoderms as indicators of brine discharge impacts

    OpenAIRE

    Fernández-Torquemada, Yolanda; González-Correa, José Miguel; Sánchez-Lizaso, José Luis

    2013-01-01

    Echinoderms are osmoconformer organisms and are expected to be very sensitive to brine discharges. The objective of this study is to examine the use of echinoderms as early warning indicators of the impact of brine discharges and its application in the management of desalination discharges. We sampled using visual census along transect lines, for nine consecutive years and in three different stations, i.e. before the seawater reverse osmosis desalination plant began operating and thereafter. ...

  13. Modeling of fuel performance and fission product release behavior during HTTR normal operation. A comparative study of the FZJ and JAERI modeling approach

    International Nuclear Information System (INIS)

    Verfondern, Karl; Sumita, Junya; Ueta, Shohei; Sawa, Kazuhiro

    2001-03-01

    For the prediction of fuel performance and fission product release behavior in the High Temperature Engineering Test Reactor, HTTR of the Japan Atomic Energy Research Institute(JAERI), during its normal operation, calculation tools were applied as have been used at the Research Center Juelich (FZJ) in safety analyses for pebble-bed HTGR designs. Calculations were made assuming the HTTR operation with a nominal operation time of 660 efpd including a 110 efpd period with elevated fuel temperatures. Fuel performance calculations by the PANAMA code with given fuel temperature distribution in the core have shown that the additional failure level of about 5x10 -6 is expected which is about twice as much as the as-fabricated through-coatings failure level. Under the extreme safety design conditions, the predicted particle failure fraction in the core increases to about 1x10 -3 in maximum. The diffusive release of metallic fission products from the fuel primarily occurs in the core layer with the maximum fuel temperature (layer 3) whereas there is hardly any contribution from layer 1 except for the recoil fraction. Silver most easily escapes the fuel; the predicted release fractions from the fuel compacts are 10% (expected) and 50% (safety design). The figures for strontium (expected: 1.5x10 -3 ), safety design: 3.1x10 -2 ) and cesium (5.6x10 -4 , 2.9x10 -2 ) reveal as well a significant fraction to originate already from intact particles. Comparison with the calculation based on JAERI's diffusion model for cesium shows a good agreement for the release behavior from the particles. The differences in the results can be explained mainly by the different diffusion coefficients applied. The release into the coolant can not modelled because of the influence of the gap between compact and graphite sleeve lowering the release by a factor of 3 to 10. For the prediction of performance and fission product release behavior of advanced ZrC TRISO particles, more experimental work is

  14. Compact Intracloud Discharges

    Energy Technology Data Exchange (ETDEWEB)

    Smith, David A. [Univ. of Colorado, Boulder, CO (United States)

    1998-11-01

    In November of 1993, mysterious signals recorded by a satellite-borne broadband VHF radio science experiment called Blackboard led to a completely unexpected discovery. Prior to launch of the ALEXIS satellite, it was thought that its secondary payload, Blackboard, would most often detect the radio emissions from lightning when its receiver was not overwhelmed by noise from narrowband communication carriers. Instead, the vast majority of events that triggered the instrument were isolated pairs of pulses that were one hundred times more energetic than normal thunderstorm electrical emissions. The events, which came to be known as TIPPs (for transionospheric pulse pairs), presented a true mystery to the geophysics community. At the time, it was not even known whether the events had natural or anthropogenic origins. After two and one half years of research into the unique signals, two ground-based receiver arrays in New Mexico first began to detect and record thunderstorm radio emissions that were consistent with the Blackboard observations. On two occasions, the ground-based systems and Blackboard even recorded emissions that were produced by the same exact events. From the ground based observations, it has been determined that TIPP events areproduced by brief, singular, isolated, intracloud electrical discharges that occur in intense regions of thunderstorms. These discharges have been dubbed CIDS, an acronym for compact intracloud discharges. During the summer of 1996, ground-based receiver arrays were used to record the electric field change signals and broadband HF emissions from hundreds of CIDS. Event timing that was accurate to within a few microseconds made possible the determination of source locations using methods of differential time of arrival. Ionospheric reflections of signals were recorded in addition to groundwave/line-of-sight signals and were used to determine accurate altitudes for the discharges. Twenty-four CIDS were recorded from three

  15. 21 CFR 1250.93 - Discharge of wastes.

    Science.gov (United States)

    2010-04-01

    ... SANITATION Sanitation Facilities and Conditions on Vessels § 1250.93 Discharge of wastes. Vessels operating... Reference: For Environmental Protection Agency's regulations for vessel sanitary discharges as related to...

  16. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Safety Resources About the Patient Education Program The Recovery Room Choosing Wisely Educational Programs Educational Programs Educational ... Lung Operation After Your Operation Your Discharge and Recovery Complete Video After Your Operation Guidance for after ...

  17. Verification of operational Quantitative Discharge Forecast (QDF for a regional warning system – the AMPHORE case studies in the upper Po River

    Directory of Open Access Journals (Sweden)

    C. Corbari

    2008-02-01

    Full Text Available In recent years, the interest in the prediction and prevention of natural hazards related to hydrometeorological events has grown due to the increased frequency of extreme rainstorms. Several research projects have been developed to test hydrometeorological models for real-time flood forecasting. However, flood forecasting systems are still not widespread in operational context. Real-world examples are mainly dedicated to the use of flood routing model, best suited for large river basins. For small basins, it is necessary to take advantage of the lag time between the onset of a rainstorm and the beginning of the hydrograph rise, with the use of rainfall-runoff transformation models. Nevertheless, when the lag time is very short, a rainfall predictor is required, as a result, meteorological models are often coupled with hydrological simulation. While this chaining allows floods to be forecasted on small catchments with response times ranging from 6 to 12 h it, however, causes new problems for the reliability of Quantitative Precipitation Forecasts (QPF and also creates additional accuracy problems for space and time scales. The aim of this work is to evaluate the degree to which uncertain QPF affects the reliability of the whole hydro-meteorological alert system for small catchments. For this purpose, a distributed hydrological model (FEST-WB was developed and analysed in operational setting experiments, i.e. the hydrological model was forced with rain observation until the time of forecast and with the QPF for the successive period, as is usual in real-time procedures. Analysis focuses on the AMPHORE case studies in Piemonte in November 2002.

  18. Trade-off analysis of discharge-desiltation-turbidity and ANN analysis on sedimentation of a combined reservoir-reach system under multi-phase and multi-layer conjunctive releasing operation

    Science.gov (United States)

    Huang, Chien-Lin; Hsu, Nien-Sheng; Wei, Chih-Chiang; Yao, Chun-Hao

    2017-10-01

    Multi-objective reservoir operation considering the trade-off of discharge-desiltation-turbidity during typhoons and sediment concentration (SC) simulation modeling are the vital components for sustainable reservoir management. The purposes of this study were (1) to analyze the multi-layer release trade-offs between reservoir desiltation and intake turbidity of downstream purification plants and thus propose a superior conjunctive operation strategy and (2) to develop ANFIS-based (adaptive network-based fuzzy inference system) and RTRLNN-based (real-time recurrent learning neural networks) substitute SC simulation models. To this end, this study proposed a methodology to develop (1) a series of multi-phase and multi-layer sediment-flood conjunctive release modes and (2) a specialized SC numerical model for a combined reservoir-reach system. The conjunctive release modes involve (1) an optimization model where the decision variables are multi-phase reduction/scaling ratios and the timings to generate a superior total release hydrograph for flood control (Phase I: phase prior to flood arrival, Phase II/III: phase prior to/subsequent to peak flow) and (2) a combination method with physical limitations regarding separation of the singular hydrograph into multi-layer release hydrographs for sediment control. This study employed the featured signals obtained from statistical quartiles/sediment duration curve in mesh segmentation, and an iterative optimization model with a sediment unit response matrix and corresponding geophysical-based acceleration factors, for efficient parameter calibration. This research applied the developed methodology to the Shihmen Reservoir basin in Taiwan. The trade-off analytical results using Typhoons Sinlaku and Jangmi as case examples revealed that owing to gravity current and re-suspension effects, Phase I + II can de-silt safely without violating the intake's turbidity limitation before reservoir discharge reaches 2238 m3/s; however

  19. Device for generation of pulsed corona discharge

    Science.gov (United States)

    Gutsol, Alexander F [San Ramon, CA; Fridman, Alexander [Marlton, NJ; Blank, Kenneth [Philadelphia, PA; Korobtsev, Sergey [Moscow, RU; Shiryaevsky, Valery [Moscow, RU; Medvedev, Dmitry [Moscow, RU

    2012-05-08

    The invention is a method and system for the generation of high voltage, pulsed, periodic corona discharges capable of being used in the presence of conductive liquid droplets. The method and system can be used, for example, in different devices for cleaning of gaseous or liquid media using pulsed corona discharge. Specially designed electrodes and an inductor increase the efficiency of the system, permit the plasma chemical oxidation of detrimental impurities, and increase the range of stable discharge operations in the presence of droplets of water or other conductive liquids in the discharge chamber.

  20. Discharge quenching circuit for counters

    International Nuclear Information System (INIS)

    Karasik, A.S.

    1982-01-01

    A circuit for quenching discharges in gas-discharge detectors with working voltage of 3-5 kV based on transistors operating in the avalanche mode is described. The quenching circuit consists of a coordinating emitter follower, amplifier-shaper for avalanche key cascade control which changes potential on the counter electrodes and a shaper of discharge quenching duration. The emitter follower is assembled according to a widely used flowsheet with two transistors. The circuit permits to obtain a rectangular quenching pulse with front of 100 ns and an amplitude of up to 3.2 kV at duration of 500 μm-8 ms. Application of the quenching circuit described permits to obtain countering characteristics with the slope less than or equal to 0.02%/V and plateau extent greater than or equal to 300 V [ru

  1. Performance of a novel baffled osmotic membrane bioreactor-microfiltration hybrid system under continuous operation for simultaneous nutrient removal and mitigation of brine discharge

    KAUST Repository

    Pathak, Nirenkumar

    2017-03-14

    The present study investigated the performance of an integrated osmotic and microfiltration membrane bioreactor system for wastewater treatment employing baffles in the reactor. Thus, this reactor design enables both aerobic and anoxic processes in an attempt to reduce the process footprint and energy costs associated with continuous aeration. The process performance was evaluated in terms of water flux, salinity build up in the bioreactor, organic and nutrient removal and microbial activity using synthetic reverse osmosis (RO) brine as draw solution (DS). The incorporation of MF membrane was effective in maintaining a reasonable salinity level (612-1434 mg/L) in the reactor which resulted in a much lower flux decline (i.e. 11.48 to 6.98 LMH) as compared to previous studies. The stable operation of the osmotic membrane bioreactor–forward osmosis (OMBR-FO) process resulted in an effective removal of both organic matter (97.84%) and nutrient (phosphate 87.36% and total nitrogen 94.28%), respectively.

  2. Randomized clinical trial on 7-days-a-week post-operative radiotherapy vs concurrent post-operative radiochemotherapy in locally advanced cancer of the oral cavity/oropharynx: a report on acute normal tissue reactions.

    Science.gov (United States)

    Suwinski, Rafal; Wozniak, Grzegorz; Misiolek, Maciej; Jaworska, Magdalena; Kozaczka, Maciej; Bal, Wieslaw; Nowara, Elzbieta; Miszczyk, Leszek

    2016-01-01

    The purpose of the study was to evaluate acute normal tissue reactions and treatment compliance in a randomized clinical trial on 7-days-a-week post-operative radiotherapy (p-CAIR) vs post-operative concurrent radiochemotherapy (p-RTCT) in locally advanced cancer of the oral cavity/oropharynx. The sample analyzed at present represents approximately 30% of the intended future trial size. The patients were randomly assigned to receive 63 Gy in 1.8-Gy fractions 7 days a week (n = 44) or 63 Gy in 1.8-Gy fractions 5 days a week with concurrent cisplatin 80-100 mg per square metre of body surface area on Days 1, 22 and 43 of the course of radiotherapy (n = 40). Acute mucosal reactions were scored using the modified Dische system. 15 (17.9%) patients, including 5 patients in p-CAIR and 10 patients in p-RTCT, did not comply with the assigned radiation treatment, mostly because of rapid tumour progression or deteriorating general performance. In p-RTCT, 22 (55%) patients received less than the intended three courses of chemotherapy mostly owing to haematological toxicity. The average maximum mucosal severity score was 14.2 in p-CAIR compared with 13.4 in p-RTCT; the difference was not statistically significant (p = 0.31). The schedules compared (p-CAIR and p-RTCT) did not differ considerably with respect to acute mucosal reactions. Haematological toxicity in p-RTCT was elevated compared with p-CAIR. Both schedules were considered tolerable with respect to acute toxicity, which justifies further recruitment to the trial. The results show that early mucosal reactions are comparable in both trial arms but haematological toxicity is more pronounced during radiochemotherapy.

  3. State Waste Discharge Permit application, 183-N Backwash Discharge Pond

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect groundwater would be subject to permitting under the structure of Chapter 173--216 (or 173--218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Department of Energy, Richland Operations Office entered into Consent Order No. DE91NM-177, (Ecology and DOE-RL 1991). The Consent Order No. DE91NM-177 requires a series of permitting activities for liquid effluent discharges. Liquid effluents on the Hanford Site have been classified as Phase I, Phase II, and Miscellaneous Streams. The Consent Order No. DE91NM-177 establishes milestones for State Waste Discharge Permit application submittals for all Phase I and Phase II streams, as well as the following 11 Miscellaneous Streams as identified in Table 4 of the Consent Order No. DE91NM-177.

  4. Lithium thionyl chloride high rate discharge

    Science.gov (United States)

    Klinedinst, K. A.

    1980-04-01

    Improvements in high rate lithium thionyl chloride power technology achieved by varying the electrolyte composition, operating temperature, cathode design, and cathode composition are discussed. Discharge capacities are plotted as a function of current density, cell voltage, and temperature.

  5. Setup Aid for Electrical-Discharge Machining

    Science.gov (United States)

    Lines, G.; Duca, J.

    1985-01-01

    Interlock assures that workpiece is correctly assembled in machining fixture. A Plunger in a Hollow Shaft actuates a switch, allowing a power supply to produce current for electrical-discharge machining. Plunger operates only when necessary parts are position.

  6. Vessel Sewage Discharges

    Science.gov (United States)

    Vessel sewage discharges are regulated under Section 312 of the Clean Water Act, which is jointly implemented by the EPA and Coast Guard. This homepage links to information on marine sanitation devices and no discharge zones.

  7. Foot amputation - discharge

    Science.gov (United States)

    Amputation - foot - discharge; Trans-metatarsal amputation - discharge ... You have had a foot amputation. You may have had an accident, or your foot may have had an infection or disease and doctors could ...

  8. Vaginal delivery - discharge

    Science.gov (United States)

    Pregnancy - discharge after vaginal delivery ... return in: 4 to 9 weeks after your delivery if you're not breastfeeding 3 to 12 ... can start sexual activity around 6 weeks after delivery, if the discharge or lochia has stopped. Women ...

  9. Atmospheric sampling glow discharge ionization source

    Science.gov (United States)

    McLuckey, S.A.; Glish, G.L.

    1989-07-18

    An atmospheric sampling glow discharge ionization source that can be used in combination with an analytical instrument which operates at high vacuum, such as a mass spectrometer. The atmospheric sampling glow discharge ionization source comprises a chamber with at least one pair of electrodes disposed therein, an inlet for a gaseous sample to be analyzed and an outlet communicating with an analyzer which operates at subatmospheric pressure. The ionization chamber is maintained at a pressure below atmospheric pressure, and a voltage difference is applied across the electrodes to induce a glow discharge between the electrodes, so that molecules passing through the inlet are ionized by the glow discharge and directed into the analyzer. The ionization source accepts the sample under atmospheric pressure conditions and processes it directly into the high vacuum instrument, bridging the pressure gap and drawing off unwanted atmospheric gases. The invention also includes a method for analyzing a gaseous sample using the glow discharge ionization source described above. 3 figs.

  10. Heart attack - discharge

    Science.gov (United States)

    ... and lifestyle Cholesterol - drug treatment Controlling your high blood pressure Deep vein thrombosis - discharge Dietary fats explained Fast food tips Heart attack - discharge Heart attack - what to ask your doctor Heart bypass ... pacemaker - discharge High blood pressure - what to ask your doctor How to read ...

  11. Illumination of Double Snapback Mechanism in High Voltage Operating Grounded Gate Extended Drain N-type Metal-Oxide-Semiconductor Field Effects Transistor Electro-Static Discharge Protection Devices

    Science.gov (United States)

    Kim, Kil Ho; Jung, Yong Icc; Shim, Jin Seop; So, Hyung Tae; Lee, Ji Hyun; Hwang, Lee Yeun; Park, Jin Won

    2004-10-01

    High current behaviors of the ‘grounded gate extended drain N-type metal-oxide-semiconductor field effects transistor’ (GG_EDNMOS) electro-static discharge (ESD) protection devices are analyzed. Both the transmission line pulse (TLP) data and the thermal incorporated 2-dimensional simulation analyses demonstrate a characteristic double snapback phenomenon after triggering of biploar junction transistor (BJT) operation. This implies the co-existence of two different on-states in high current region. The 2nd on-state, characterized by extremely low snapback holding voltage and low on-resistance, seems to be responsible for the vulnerability of the device under ESD stress. Simulation based contour analyses reveal that combination of BJT operation and deep electron channeling induced by high electron injection gives rise to the 2nd on-state. Thus, the deep electron channel formation needs to be prevented in order to realize stable and robust ESD protection performance. Further studies reveal that the N-drift implant dose, among various process parameters, is a critical factor to determine the formation of deep electron channeling and consequential occurrence of the 2nd on-state. Based on our analyses, general methodology to avoid the double snapback and to realize stable ESD protection is to be discussed.

  12. Intermittent water discharges for family orchards using photovoltaic energy and a system self-operating for a TDF; Riego intermitente para huertos familiares usando energia fotovoltaica y un sistema auto-operante para un TDF

    Energy Technology Data Exchange (ETDEWEB)

    Millan Diaz, Candido; Garcia Villanueva, Nahun H [Instituto Mexicano de Tecnologia del Agua, Jiutepec, Morelos (Mexico); Sanchez Juarez, Aaron [Centro de Investigacion en Energia, UNAM, Temixco, Morelos (Mexico)

    2000-07-01

    This work present the design of a system for automatic opening and closing of a Discharge Bottom Tank (DBT) to produce intermittent water discharges. In order to modernize and increase the production in the family orchards, the application of a integral system built with a self-operating opening and closing valve, a DBT and a PV water pumping system, is suggested. The results obtained from this integral system, is suggested. The results obtained from this integral system applied in a family experimental farm of 144 m{sup 2} are shown below. The PV system size for pumping the required water per day for that family prototype farm was of 106 W-p. Comparing the yield obtained for green tomato, red tomato, and squash in existing technical irrigation process against our integral system, it is shown that our production is almost the same. [Spanish] En este trabajo se presenta el diseno de un sistema de apertura y cierre automatico para producir descargas de agua intermitentes en un Tanque de Descarga de Fondo (TDF). Con el objeto de aumentar la produccion agricola en los huertos familiares, se sugiere la aplicacion de un sistema integral, para riego intermitente en ellos, formado por: el sistema auto operante disenado, un TDF y un sistema de bombeo fotovoltaico, como una alternativa para modernizar y mejorar las eficiencias del riego por gravedad en ellos. Se dan a conocer los resultados obtenidos de este sistema integral en un huerto familiar experimental de 144 m{sup 2}. El tamano del sistema de bombeo fotovoltaico para extraer el agua requerida por dia-cultivo para ese huerto familiar prototipo fue de 106 W-p. El rendimiento por hectarea obtenido para cultivos de jitomate, tomate y calabacita muestra que nuestra produccion, usando el sistema integral, es comparable con los rendimientos por hectarea que se obtienen con metodologias de riego tecnificadas.

  13. Pulsed discharge plasmas in supercritical carbon dioxide

    OpenAIRE

    Kiyan, Tsuyoshi; Uemura, A.; Tanaka, K.; Zhang, C.H.; Namihira, Takao; Sakugawa, Takashi; Katsuki, Sunao; Akiyama, Hidenori; Roy, B.C.; Sasaki, M.; Goto, M.; キヤン, ツヨシ; ナミヒラ, タカオ; サクガワ, タカシ; カツキ, スナオ

    2005-01-01

    In recent years, several studies about electrical discharge plasma in supercritical carbon dioxide (CO2) have been carried out. One of the unique characteristics of supercritical fluid is a large density fluctuation near the critical point that can result in marked dramatic changes of thermal conductivity. Therefore, the electrical discharge plasma produced in supercritical fluid has unique features and reactions unlike those of normal plasma produced in gas phase. In our experiments, two typ...

  14. Normalized modes at selected points without normalization

    Science.gov (United States)

    Kausel, Eduardo

    2018-04-01

    As every textbook on linear algebra demonstrates, the eigenvectors for the general eigenvalue problem | K - λM | = 0 involving two real, symmetric, positive definite matrices K , M satisfy some well-defined orthogonality conditions. Equally well-known is the fact that those eigenvectors can be normalized so that their modal mass μ =ϕT Mϕ is unity: it suffices to divide each unscaled mode by the square root of the modal mass. Thus, the normalization is the result of an explicit calculation applied to the modes after they were obtained by some means. However, we show herein that the normalized modes are not merely convenient forms of scaling, but that they are actually intrinsic properties of the pair of matrices K , M, that is, the matrices already "know" about normalization even before the modes have been obtained. This means that we can obtain individual components of the normalized modes directly from the eigenvalue problem, and without needing to obtain either all of the modes or for that matter, any one complete mode. These results are achieved by means of the residue theorem of operational calculus, a finding that is rather remarkable inasmuch as the residues themselves do not make use of any orthogonality conditions or normalization in the first place. It appears that this obscure property connecting the general eigenvalue problem of modal analysis with the residue theorem of operational calculus may have been overlooked up until now, but which has in turn interesting theoretical implications.Á

  15. Energy discharge heater power supply

    International Nuclear Information System (INIS)

    Jaskierny, W.

    1992-11-01

    The heater power supply is intended to supply capacitively stored,energy to embedded heater strips in cryo magnets. The amount of energy can be controlled by setting different charge different capacitor values. Two chassis' can be operated in series or interlocks are provided. The charge voltage, number of capacitors pulse can be monitored. There and dual channel has two discharge supplies in one chassis. This report reviews the characteristics of this power supply further

  16. Oscillations and trends of river discharge in the southern Central Andes and linkages with climate variability

    Science.gov (United States)

    Castino, Fabiana; Bookhagen, Bodo; Strecker, Manfred R.

    2017-12-01

    This study analyzes the discharge variability of small to medium drainage basins (102-104 km2) in the southern Central Andes of NW Argentina. The Hilbert-Huang Transform (HHT) was applied to evaluate non-stationary oscillatory modes of variability and trends, based on four time series of monthly-normalized discharge anomaly between 1940 and 2015. Statistically significant trends reveal increasing discharge during the past decades and document an intensification of the hydrological cycle during this period. An Ensemble Empirical Mode Decomposition (EEMD) analysis revealed that discharge variability in this region can be best described by five quasi-periodic statistically significant oscillatory modes, with mean periods varying from 1 to ∼20 y. Moreover, we show that discharge variability is most likely linked to the phases of the Pacific Decadal Oscillation (PDO) at multi-decadal timescales (∼20 y) and, to a lesser degree, to the Tropical South Atlantic SST anomaly (TSA) variability at shorter timescales (∼2-5 y). Previous studies highlighted a rapid increase in discharge in the southern Central Andes during the 1970s, inferred to have been associated with the global 1976-77 climate shift. Our results suggest that the rapid discharge increase in the NW Argentine Andes coincides with the periodic enhancement of discharge, which is mainly linked to a negative to positive transition of the PDO phase and TSA variability associated with a long-term increasing trend. We therefore suggest that variations in discharge in this region are largely driven by both natural variability and the effects of global climate change. We furthermore posit that the links between atmospheric and hydrologic processes result from a combination of forcings that operate on different spatiotemporal scales.

  17. Measurements and calculations for determination of discharge of 41Ar from IFEs research reactor JEEP II at Kjeller, Norway

    International Nuclear Information System (INIS)

    Raaum, A.; Straelberg, E.

    2003-01-01

    41 Ar is formed by neutron irradiation of 40 Ar, which occurs naturally in air with a concentration of 9300 ppm. The discharge of 41 Ar from IFEs research reactor Jeep II is yearly reported to the Norwegian Radiation Protection Authority (NRPA). Until year 2000 the reported values were based on theoretical calculations of produced 41 Ar per operating hour of 6.8 GBq/h. During 2000 and 2001 the reactor was upgraded to increase the irradiation capacity and to meet the markets demand for irradiation of 5'Si-crystalls. After the upgrading, measurements and calculations were initiated to determine the new discharge rate for 41 Ar. During reactor operation an approximately constant discharge of 41 Ar is expected, mainly due to irradiation of air in open beam channels. In addition 41 Ar is released from irradiation pockets when they are opened to transfer samples in and out during reactor stop. The new value for discharge rate was determined from measurements of air samples from the discharge channel during operation and theoretical calculations of the release from the irradiation pockets. The new discharge rate was determined to 5.9 ± 0.5 GBq/h, which is a small reduction compared to the former value of 6.8 GBq/h. A small reduction in discharge rate was expected because the number of air-filled irradiation pockets was reduced after the upgrading. In a normal year the discharge of 41 Ar will be about 2 % of the Institutes discharge permission. (orig.)

  18. 33 CFR 157.31 - Discharges: Chemical additives.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Discharges: Chemical additives... OIL IN BULK Vessel Operation § 157.31 Discharges: Chemical additives. No person may use a chemical additive to circumvent the discharge requirements in §§ 157.27, 157.29, 157.37, 157.39, and 157.43. ...

  19. Early discharge following birth

    DEFF Research Database (Denmark)

    Nilsson, Ingrid M. S.; Kronborg, Hanne; Knight, Christopher H.

    2017-01-01

    of discharge after birth. Results In total 34% mothers were discharged within 12 hours (very early) and 25% between 13 and 50 hours (early), respectively. Vaginal birth and multiparity were the most influential predictors, as Caesarean section compared to vaginal birth had an OR of 0.35 (CI 0....... Smoking, favourable social support and breastfeeding knowledge were significantly associated with discharge within 12 hours. Finally time of discharge varied significantly according to region and time of day of birth. Conclusions Parity and birth related factors were the strongest predictors of early...

  20. Studying discharges in the Gas Electron Multiplies in Alice Detector

    CERN Document Server

    EُlGedawy, Omar

    2016-01-01

    Characterizing discharges is very important in the operation of the GEM detector. Once the discharges happen, a current will go through the GEM, the voltages across the GEM foils sides drop, charge amplification cannot take place anymore, resulting in a loss of signal. So the goal is to understand how the discharges evolve and propagate, in order to find requirements on the voltage settings, which allow to decrease the discharge probability.

  1. Developing a Simple Unique Head-Discharge Equation for Pivot Weirs with Different Side Contractions

    Directory of Open Access Journals (Sweden)

    neda Sheikh Rezazadeh Nikou

    2016-10-01

    Full Text Available Introduction: Pivot weirs (sharp crested inclined weirs, Fig. 1-a is frequently used for discharge measurement, controlling water surface and flow diversion. Some typical features of pivot weirs are: (a overshot design for better water level control, (b Their application as head gates, turnout or check structure which requiring low head loss and high accuracy, (c ease of removing sediment deposit behind the weir, and (d ability to manage and monitor on-site or operating remotely when connected to a supervisory control and data acquisition (SCADA network. Kindsvater and Carter (8 derived a weir discharge equation based on energy and continuity equations. Hulsing (4 determined head-discharge relationship of inclined suppressed sharp crested weir with the slope of 3:3, 2:3 and 1:3 toward downstream and compared them with the equivalent normal sharp crested weir. In the USBR report on pivot weirs (regarding The Boulder Canyon Project,1948 the head discharge data of the suppressed pivot weir were presented in a channel with 5.5m length, 2.9m depth and 0.61m width. Some field experiments were also carried out in the IID (Imperial Irrigation District on a trapezoidal cross-section (0.61 m bottom width channel with pivot weir of 1.7m length, and two different widths of 1.63m. The flow rate (350-880 lit/s was held constant and different angles (15-50° calibrated instead of holding the angle constant and varying the flow rate. Some other laboratory tests were performed with Wahlin and Replogle (1994 on two pivot weirs with 1.2 m and 1.14 m width for the 0.61 m and 0.46 m length of blade and contraction factor of 0.925. RUBICON Company established an extensive operation on the application and automation of pivot weirs in irrigation channels in Australia (Www.rubicon.com. All previous studies concentrated on modifying the normal rectangular weir head-discharge equation so that it can be used for the pivot weirs. In this study, it is trying to derive a

  2. Computing discharge using the index velocity method

    Science.gov (United States)

    Levesque, Victor A.; Oberg, Kevin A.

    2012-01-01

    Application of the index velocity method for computing continuous records of discharge has become increasingly common, especially since the introduction of low-cost acoustic Doppler velocity meters (ADVMs) in 1997. Presently (2011), the index velocity method is being used to compute discharge records for approximately 470 gaging stations operated and maintained by the U.S. Geological Survey. The purpose of this report is to document and describe techniques for computing discharge records using the index velocity method. Computing discharge using the index velocity method differs from the traditional stage-discharge method by separating velocity and area into two ratings—the index velocity rating and the stage-area rating. The outputs from each of these ratings, mean channel velocity (V) and cross-sectional area (A), are then multiplied together to compute a discharge. For the index velocity method, V is a function of such parameters as streamwise velocity, stage, cross-stream velocity, and velocity head, and A is a function of stage and cross-section shape. The index velocity method can be used at locations where stage-discharge methods are used, but it is especially appropriate when more than one specific discharge can be measured for a specific stage. After the ADVM is selected, installed, and configured, the stage-area rating and the index velocity rating must be developed. A standard cross section is identified and surveyed in order to develop the stage-area rating. The standard cross section should be surveyed every year for the first 3 years of operation and thereafter at a lesser frequency, depending on the susceptibility of the cross section to change. Periodic measurements of discharge are used to calibrate and validate the index rating for the range of conditions experienced at the gaging station. Data from discharge measurements, ADVMs, and stage sensors are compiled for index-rating analysis. Index ratings are developed by means of regression

  3. Graywater Discharges from Vessels

    Science.gov (United States)

    2011-11-01

    both sewage and graywater, or sewage collected from “ honey dipper” trucks, which may contain far less graywater, depending on the source (See... crystal clean effluent discharge. As a reference, Cruiseliners equipped with Scanship AWP systems has obtained continous discharge permits in Hawaii and

  4. Paediatric vaginal discharge

    African Journals Online (AJOL)

    Vaginal discharge in the prepubertal patient is a common symptom, and can be a source of distress for the caregiver and con- cern for the healthcare worker. Several factors predispose these patients to the development of recurrent vaginal discharge. Unless noticed by the caregiver, this problem can persist for long periods ...

  5. Prostate brachytherapy - discharge

    Science.gov (United States)

    ... nausea or vomiting Any new or unusual symptoms Alternative Names Implant therapy - prostate cancer - discharge; Radioactive seed placement - discharge References D'Amico AV, Nguyen PL, Crook JM, et al. Radiation therapy for prostate cancer. In: Wein AJ, Kavoussi LR, Partin AW, Peters CA, ...

  6. Replacement of five main block valves without interruption of normal operation in a remote NGL station placed at 13400 FT AMSL, challenge and strategies

    Energy Technology Data Exchange (ETDEWEB)

    Quinto, Yamil; Morales, Raul; Elorreaga, Gerson [Compania Operadora del Gas del Amazonas, Lima (Peru)

    2012-07-01

    The present paper is aimed to share experience of the replacement of five block valves carried on in a pressure reduction station remotely operated and located in a remote area in The Andes of Peru at 13400 ft AMSL. To accomplish the job, it was necessary the construction of a temporary bypass made of carbon steel pipeline with its own regulating, instrumentation and automation facilities, hence capable of reduce the NGL pressure, controlled and remotely operated by a SCADA system. The temporary bypass connection and disconnection to put on service was carried out using Hot Tap and Line Stop equipment. The replacement of the five block valves was met without interruption of the hydrocarbons flow, and resetting the pressure reduction station to steady operating conditions. Besides the operating works these activities involve safety considerations for personal working in high altitudes. The outputs were the successful replacements of the block valves, and most important was that the NGL continuous flow was met, so both the production and processing plants were supplied with the daily transportation rates in standard conditions, and in accordance with the requirements of the plant operation. (author)

  7. CO-AXIAL DISCHARGES

    Science.gov (United States)

    Luce, J.S.; Smith, L.P.

    1960-11-22

    A method and apparatus are given for producing coaxial arc discharges in an evacuated enclosure and within a strong, confining magnetic field. The arcs are maintained at a high potential difference. Electrons will diffuse to the more positive arc from the negative arc, and positive ions will diffuse from the more positive arc to the negative arc. Coaxial arc discharges have the advantage that ions which return to strike the positive arc discharge will lose no energy since they do not strike a solid wall or electrode. Those discharges are useful in confining an ionized plasma between the discharges, and have the advantage of preventing impurities from the walls of the enclosure from entering ihe plasma area because of the arc barrier set up bv the cylindrical outer arc.

  8. Predicting tile drainage discharge

    DEFF Research Database (Denmark)

    Iversen, Bo Vangsø; Kjærgaard, Charlotte; Petersen, Rasmus Jes

    More than 50 % of Danish agricultural areas are expected to be artificial tile drained. Transport of water and nutrients through the tile drain system to the aquatic environment is expected to be significant. For different mitigation strategies such as constructed wetlands an exact knowledge...... of the water load coming from the tile drainage system is therefore essential. This work aims at predicting tile drainage discharge using dynamic as well as a statistical predictive models. A large dataset of historical tile drain discharge data, daily discharge values as well as yearly average values were...... used in the analysis. For the dynamic modelling, a simple linear reservoir model was used where different outlets in the model represented tile drain as well as groundwater discharge outputs. This modelling was based on daily measured tile drain discharge values. The statistical predictive model...

  9. The design of remote discharge scenario management system on EAST

    International Nuclear Information System (INIS)

    Chai, W.T; Xiao, B.J; Yuan, Q.P; Zhang, R.R.

    2016-01-01

    Highlights: • The remote discharge scenario management system is established on EAST, it provides some useful function for operators to manage discharge scenarios and formulate discharge schedule. • Operators can use this system to formulate discharge schedule on account of it can electing optimal scenarios automatically. • The system is not only for local user but also for remote user. • In the future, we can combine with actual discharge data and data mining technology to acquire optimal configuration, which to generate expert database and guiding experiment. - Abstract: The discharge scenarios on EAST plasma control system (PCS), characterized by different waveform parameters and different hardware requirements, will need a systematic discharge scenario management system for remote and local operators, in order to optimize storage structure and rationally manage discharge time. The remote management of discharge scenarios will require extending the functionalities of the present PCS “future shot” and “next shot” modules. Taking advantage of database technique, the operators can acquire detail information of all discharge scenarios directly without PCS user interface and search the specified scenarios by key words. In addition, the system can elect optimal scenarios automatically based on discharge schedule and plasma pulse setting for later artificial selection. To this purpose, a new remote discharge scenario management system (RDSMS) basis for Web is being conceived on EAST. The system contains a database with functions of “user management”, “scenario verification”, “prepared scenario management”, “actual discharge scenario management” and “discharge schedule management”. This paper will present the relevant conceptual design and give an account of the test results for implementation on EAST discharges.

  10. The design of remote discharge scenario management system on EAST

    Energy Technology Data Exchange (ETDEWEB)

    Chai, W.T, E-mail: wtchai@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); University of Science and Technology of China, Hefei, Anhui (China); Xiao, B.J [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); University of Science and Technology of China, Hefei, Anhui (China); Yuan, Q.P; Zhang, R.R. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China)

    2016-11-15

    Highlights: • The remote discharge scenario management system is established on EAST, it provides some useful function for operators to manage discharge scenarios and formulate discharge schedule. • Operators can use this system to formulate discharge schedule on account of it can electing optimal scenarios automatically. • The system is not only for local user but also for remote user. • In the future, we can combine with actual discharge data and data mining technology to acquire optimal configuration, which to generate expert database and guiding experiment. - Abstract: The discharge scenarios on EAST plasma control system (PCS), characterized by different waveform parameters and different hardware requirements, will need a systematic discharge scenario management system for remote and local operators, in order to optimize storage structure and rationally manage discharge time. The remote management of discharge scenarios will require extending the functionalities of the present PCS “future shot” and “next shot” modules. Taking advantage of database technique, the operators can acquire detail information of all discharge scenarios directly without PCS user interface and search the specified scenarios by key words. In addition, the system can elect optimal scenarios automatically based on discharge schedule and plasma pulse setting for later artificial selection. To this purpose, a new remote discharge scenario management system (RDSMS) basis for Web is being conceived on EAST. The system contains a database with functions of “user management”, “scenario verification”, “prepared scenario management”, “actual discharge scenario management” and “discharge schedule management”. This paper will present the relevant conceptual design and give an account of the test results for implementation on EAST discharges.

  11. Modelling electric discharge chemistry

    International Nuclear Information System (INIS)

    McFarlane, J.; Wren, J.C.

    1991-07-01

    The chemistry occurring in a electric discharge was modelled to predict how it would be influenced by discharge conditions. The discharge was characterized by a calculated Boltzmann electron-energy distribution, from which rate constants for electron-molecule processes in air were determined. These rate constants were used in a chemical kinetics calculation that also included reactions between neutral molecules, ions, free radicals and electronically excited species. The model describes how the discharge chemistry was influenced by humidity, electric field, electron number density, and concentrations of key reagents identified in the study. The use of an electric discharge to destroy airborne contaminant molecules was appraised, the targeted contaminants being CF 2 Cl 2 , HCN, and SO 2 . The modelling results indicate that an electric discharge should be able to remove HCN and CF 2 Cl 2 effectively, especially if the discharge conditions have been optimized. Effective destruction is achieved with a moderate electric field (over 1 x 10 -15 V.cm 2 ), a substantial electron number density (over 1 x 10 12 cm -3 ), and the presence of H 2 0 in the process air. The residence time in the discharge was also shown to be important in contaminant destruction. An attempt was made to explain the results of the electric discharge abatement of SO 2 , a component of a simulated flue-gas mixture. Results from the model indicate that the discharge parameters that increase the concentration of hydroxyl radical also increase the rate of decomposition of SO 2 . An objective of the study was to explain the apparent enhancement of SO 2 destruction by the presence of a small amount of NO 2 . It was thought that a likely explanation would be the stabilization of HOSO 2 , an important intermediate in the oxidation of SO 2 by NO 2 . (49 figs., 14 tabs., 75 refs.)

  12. PWR Fuel licensing in France - from design to reprocessing: licensing of nuclear PWR fuel rod design to satisfy with criteria for normal and abnormal fuel operation in France

    International Nuclear Information System (INIS)

    Beraha, R.

    1999-01-01

    In this lecture are presented: French regulatory context; Current fuel management methods; Request from the french operator EdF; Most recent actions of the french Nuclear safety authority; Fuel assemblies deformations (impact of high burn-up; investigations during reactor's exploitation; control rods drop off times)

  13. Radionuclides, Metals, and Hydrocarbons in Oil and Gas Operational Discharges and Environmental Samples Associated with Offshore Production Facilities on the Texas/Louisiana Continental Shelf with an Environmental Assessment of Metals and Hydrocarbons

    International Nuclear Information System (INIS)

    1997-06-01

    This report presents concentrations of radionuclides, metals, and hydrocarbons in samples of produced water and produced sand from oil and gas production platforms located offshore Texas and Louisiana. concentrations in produced water discharge plume / receiving water, ambient seawater, sediment, interstitial water, and marine animal tissue samples collected in the vicinity of discharging platforms and reference sites distant from discharges are also reported and discussed. An environmental risk assessment is made on the basis of the concentration of metals and hydrocarbons determined in the samples

  14. Radionuclides, Metals, and Hydrocarbons in Oil and Gas Operational Discharges and Environmental Samples Associated with Offshore Production Facilities on the Texas/Louisiana Continental Shelf with an Environmental Assessment of Metals and Hydrocarbons.

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    This report presents concentrations of radionuclides, metals, and hydrocarbons in samples of produced water and produced sand from oil and gas production platforms located offshore Texas and Louisiana. concentrations in produced water discharge plume / receiving water, ambient seawater, sediment, interstitial water, and marine animal tissue samples collected in the vicinity of discharging platforms and reference sites distant from discharges are also reported and discussed. An environmental risk assessment is made on the basis of the concentration of metals and hydrocarbons determined in the samples.

  15. Radionuclides, Metals, and Hydrocarbons in Oil and Gas Operational Discharges and Environmental Samples Associated with Offshore Production Facilities on the Texas/Louisiana Continental Shelf with an Environmental Assessment of Metals and Hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Continental Shelf Associates, Inc.

    1999-08-16

    This report presents concentrations of radionuclides, metals, and hydrocarbons in samples of produced water and produced sand from oil and gas production platforms located offshore Texas and Louisiana. Concentrations in produced water discharge plume/receiving water, ambient seawater, sediment, interstitial water, and marine animal tissue samples collected in the vicinity of discharging platforms and reference sites distant from discharges are also reported and discussed. An environmental risk assessment is made on the basis of the concentrations of metals and hydrocarbons determined in the samples.

  16. Construction of an external electrode for determination of electrochemical corrosion potential in normal operational conditions of an BWR type reactor for hot cells; Construccion de un electrodo externo para determinacion del potencial de corrosion electroquimico en condiciones normales de operacion de un reactor tipo BWR para celdas calientes

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar T, J.A.; Rivera M, H.; Hernandez C, R. [Departamento de Sintesis y Caracterizacion de Materiales, Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2001-07-01

    The behavior of the corrosion processes at high temperature requires of external devices that being capable to resist a temperature of 288 Centigrade and a pressure of 80 Kg/cm{sup 2}, to give stable and reproducible results of some variable and resisting physically and chemically the radiation. The external electrode of Ag/AgCl fulfils all the requirements in the determination of the electrochemical corrosion potential under normal operational conditions of a BWR type reactor in hot cells. (Author)

  17. Ready to Go Home? Patients' Experiences of the Discharge Process in an Enhanced Recovery After Surgery (ERAS) Program for Colorectal Surgery.

    Science.gov (United States)

    Jones, D; Musselman, R; Pearsall, E; McKenzie, M; Huang, H; McLeod, Robin S

    2017-11-01

    With the adoption of enhanced recovery after surgery (ERAS) programs, patients are being discharged earlier and require more post-discharge teaching, educational materials, and information. The purpose of this study is to assess satisfaction, discharge needs, and follow-up concerns of patients within an ERAS implementation program (iERAS). Between 2012 and 2015, the iERAS program was undertaken at an academic hospital where 554 patients having elective colorectal surgery were enrolled. After discharge, patients were sent a survey containing multiple choice questions, preference ranking, and open-ended questions. Free-text responses were analyzed through a thematic approach. Overall, 496 patients were mailed surveys and 219 (44.2%) completed the survey. Ninety-three percent were satisfied with the discharge information, and 90% felt they were ready for discharge. Eighty-six percent of patients saw their surgeon at 6 weeks, and 88% were satisfied with this follow-up plan. Some patients felt they had inadequate post-operative information, including how to resolve complications while at home and lack of reliable information for common post-operative occurrences. Patients with ostomies wanted more information about what to expect post-discharge and what symptoms were normal. Support from the homecare team and having a surgical nurse available were considered to be essential. Improved post-operative education for surgical patients prior to discharge within iERAS is required to facilitate patient-centered discharge planning. Such interventions may help decrease unplanned hospital visits during the immediate post-discharge period.

  18. Gas Balance in Ohmic Discharges on DIII-D

    Science.gov (United States)

    West, W. P.; Brooks, N. H.; Leonard, A. W.; Whyte, D. G.; Lipschultz, B.; Watkins, J. G.; Groth, M.; Lasnier, C. J.; Fenstermacher, M. E.; Boedo, J. A.; Rudakov, D. L.; Unterberg, E. A.

    2008-11-01

    Wall retention of deuterium (D) fueling gas in ohmic discharges on DIII-D has been measured by operation in a closed system with no exhaust from the vacuum vessel. Vessel pressures after identical gas injection, with and without plasma operation, are compared. The ion flux to the divertor was measured with fixed Langmuir probes, and SOL plasma density and temperatures were measured with fast-stroke probes. Ten similar discharges with no in-vessel pumping were repeated, followed by three discharges with in-vesssel divetor cryopumps active then regenerated after each discharge. Preliminary analysis indicates the retained D in ohmic discharges is ˜90 (20)% of the injected gas in the un(pumped) discharges, whereas previous gas balance during cryopumped ELMing H-mode discharges indicated no retention. In both the pumped and unpumped ohmic cases, the retained D is ˜1% of the ion fluence to the wall.

  19. Capacitor discharge engineering

    CERN Document Server

    Früngel, Frank B A

    1976-01-01

    High Speed Pulse Technology, Volume III: Capacitor Discharge Engineering covers the production and practical application of capacitor dischargers for the generation and utilization of high speed pulsed of energy in different forms. This nine-chapter volume discusses the principles of electric current, voltage, X-rays, gamma rays, heat, beams of electrons, neutrons and ions, magnetic fields, sound, and shock waves in gases and liquids. Considerable chapters consider the applications of capacitor discharges, such as impulse hardening of steel, ultrapulse welding of precision parts, X-ray flash t

  20. Plasma return current discharge

    International Nuclear Information System (INIS)

    Mangano, J.A.; Hsia, J.; Jacob, J.H.; Srivastava, B.N.

    1978-01-01

    A discharge technique based on the use of an electron-beam-induced plasma return current to produce and heat large-volume plasmas is described. The results of discharge studies using this technique in attachment-dominated mixtures are presented. The results are found to be adequately described by a simple theory. The electron attachment rate by F 2 inferred from these measurements agrees well with those of other workers. KrF laser action at 248 nm is reported in return-current discharge-excited mixtures of F 2 /Kr/He

  1. FDX: a fast discharge homopolar generator

    International Nuclear Information System (INIS)

    Weldon, W.F.; Rylander, H.G.; Woodson, H.H.

    1977-01-01

    A study was undertaken to determine the fundamental limitations to the discharge times of homopolar generators. As a result of the study, a Fast Discharge Experiment (FDX) was proposed. FDX is a small (365 kJ), counterrotating disk type homopolar generator designed to explore the limits to homopolar generator discharge times. The FDX rotors are forged aluminum alloy with flame sprayed copper slip rings. Solid copper graphite brushes are used with a 95% packing factor on the slip rings. The high magnetic field required for fast discharge (3.6 T average) is provided by discharging the CEM 5.0 MJ homopolar generator into a four-turn, graphite-reinforced, room temperature copper coil. Since the field is pulsed and FDX rotors cannot be self motored, they are brought up to speed with two 37 kW air turbines. The two aluminum rotors are 30 cm in diameter and of a rimmed, modified constant stress configuration. They are designed for a maximum operating speed of 28,000 r/min at which point they each store 182.5 kJ and develop 104 V. The aluminum discharge coax is approximately 38 cm in diameter and is designed to carry the 1.88 MA anticipated from a half speed (14,000 r/min) short circuit discharge which would stop the rotors in 1.0 ms. It is predicted that the machine will ring on its own internal impedance for approximately five cycles in this mode. The discharge coax is shorted by four very fast making switches. Additional impedance can be introduced into the discharge circuit by extending the switch coaxes to allow full speed 1.4 MA discharges in approximately 3.5 ms

  2. Numerical investigation of dielectric barrier discharges

    Science.gov (United States)

    Li, Jing

    1997-12-01

    A dielectric barrier discharge (DBD) is a transient discharge occurring between two electrodes in coaxial or planar arrangements separated by one or two layers of dielectric material. The charge accumulated on the dielectric barrier generates a field in a direction opposite to the applied field. The discharge is quenched before an arc is formed. It is one of the few non-thermal discharges that operates at atmospheric pressure and has the potential for use in pollution control. In this work, a numerical model of the dielectric barrier discharge is developed, along with the numerical approach. Adaptive grids based on the charge distribution is used. A self-consistent method is used to solve for the electric field and charge densities. The Successive Overrelaxation (SOR) method in a non-uniform grid spacing is used to solve the Poisson's equation in the cylindrically-symmetric coordinate. The Flux Corrected Transport (FCT) method is modified to solve the continuity equations in the non-uniform grid spacing. Parametric studies of dielectric barrier discharges are conducted. General characteristics of dielectric barrier discharges in both anode-directed and cathode-directed streamer are studied. Effects of the dielectric capacitance, the applied field, the resistance in external circuit and the type of gases (O2, air, N2) are investigated. We conclude that the SOR method in an adaptive grid spacing for the solution of the Poisson's equation in the cylindrically-symmetric coordinate is convergent and effective. The dielectric capacitance has little effect on the g-factor of radical production, but it determines the strength of the dielectric barrier discharge. The applied field and the type of gases used have a significant role on the current peak, current pulse duration and radical generation efficiency, discharge strength, and microstreamer radius, whereas the external series resistance has very little effect on the streamer properties. The results are helpful in

  3. THE EVALUATION OF POSSIBILITY OF NORMAL OPERATION OF CABLES BASED ON TWISTED PAIRS WITH PVC JACKET UNDER THE CONDITIONS OF HIGH HUMIDITY AND TEMPERATURE

    Directory of Open Access Journals (Sweden)

    G. V. Bezprozvannych

    2017-10-01

    Full Text Available Introduction. Development of cables for structured cabling systems based on twisted pairs for shipbuilding is carried out in two main directions: increasing the fire safety of cables and increasing the long-term permissible operating temperature by using new, more heat-resistant, electrical insulating materials. Purpose. Substantiation of the possibility of unshielded cables on the basis of unshielded twisted pairs with thermoplastic polyethylene insulation in PVC protective jacket in conditions of high humidity and high operating temperatures on the basis of the results of accelerated aging. Methodology. The cycle of aging under conditions of increased humidity is performed for 336 hours. Then the sample was under natural drying conditions for 1440 hours. Thermal aging in a thermostat at 90 °C was carried out in two stages: first – for 206 hours, the second – for 260 hours. In the initial state and after accelerated aging, measurements of the capacitance and tangent of the dielectric loss angle of all the insulating gaps at frequencies of 100 Hz, 1 and 10 kHz were performed. Results. According to the results of accelerated aging under conditions of high humidity and temperature, it is established that the design of an unshielded cable based on unshielded twisted pairs with thermoplastic polyethylene insulation in a protective coating based on PVC-plastic is resistant to external influencing factors. Practical value. The prolonged holding at temperature of 90 °C is equivalent to operation at temperature of 40 °C for 6.8 years. At higher operating temperatures, the lifetime of the cable is significantly reduced.

  4. Filament Discharge Phenomena in Fingerprint Acquisition by Dielectric Barrier Discharge

    International Nuclear Information System (INIS)

    Weng Ming; Xu Weijun; Liu Qiang

    2007-01-01

    In this paper, the dielectric barrier discharge fingerprint acquisition technique is introduced. The filament discharge phenomena were observed in the process of fingerprint acquisition. The filament discharge reduced the quality of fingerprint images. Obviously, it was necessary to eliminate streamer discharges in order to get good fingerprint images. The streamer discharge was considered to be the cause of the filament discharge in the experiment. The relationship between the critical electric field and the discharge gap was calculated with the Raether's model of streamer discharge. The calculated results and our experiment proved that it would be difficult for the streamer discharge to occur when the discharge gap was narrow. With a narrow discharge gap, the discharge was homogeneous, and the fingerprint images were clear and large in area. The images obtained in the experiment are very suitable for fingerprint identification as they contain more information

  5. Implantable cardioverter defibrillator - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000108.htm Implantable cardioverter defibrillator - discharge To use the sharing features on this page, please enable JavaScript. An implantable cardioverter-defibrillator (ICD) is a device that detects a life- ...

  6. Hypospadias repair - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000158.htm Hypospadias repair - discharge To use the sharing features on this page, please enable JavaScript. Your child had hypospadias repair to fix a birth defect in which ...

  7. Concussion - child - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000125.htm Concussion in children - discharge To use the sharing features ... enable JavaScript. Your child was treated for a concussion . This is a mild brain injury that can ...

  8. Urethral discharge culture

    Science.gov (United States)

    ... Genital exudate culture; Culture - genital discharge or exudate; Urethritis - culture ... Augenbraun MH, McCormack WM. Urethritis. In: Bennett JE, Dolin R, Blaser MJ, eds. Mandell, Douglas, and Bennett's Principles and Practice of Infectious Diseases . 8th ed. ...

  9. Thyroid gland removal - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000293.htm Thyroid gland removal - discharge To use the sharing features ... surgery. This will make your scar show less. Thyroid Hormone Replacement You may need to take thyroid ...

  10. Atrial fibrillation - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000237.htm Atrial fibrillation - discharge To use the sharing features on this ... have been in the hospital because you have atrial fibrillation . This condition occurs when your heart beats faster ...

  11. Asthma - child - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000001.htm Asthma - child - discharge To use the sharing features on this ... care for your child. Take Charge of Your Child's Asthma at Home Make sure you know the asthma ...

  12. Small bowel resection - discharge

    Science.gov (United States)

    ... Ileostomy and your diet Ileostomy - caring for your stoma Ileostomy - changing your pouch Ileostomy - discharge Ileostomy - what to ask your doctor Low-fiber diet Surgical wound care - open Types of ileostomy Wet-to-dry dressing ...

  13. Kidney stones - lithotripsy - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000136.htm Kidney stones and lithotripsy - discharge To use the sharing features on this page, please enable JavaScript. A kidney stone is a solid mass made up of tiny ...

  14. Chest radiation - discharge

    Science.gov (United States)

    Radiation - chest - discharge; Cancer - chest radiation; Lymphoma - chest radiation ... When you have radiation treatment for cancer, your body goes through changes. About 2 weeks after your first treatment: It may be hard ...

  15. Breast radiation - discharge

    Science.gov (United States)

    Radiation - breast - discharge ... away around 4 to 6 weeks after the radiation treatment is over. You may notice changes in ... breast looks or feels (if you are getting radiation after a lumpectomy). These changes include: Soreness or ...

  16. Brain radiation - discharge

    Science.gov (United States)

    Radiation - brain - discharge; Cancer-brain radiation; Lymphoma - brain radiation; Leukemia - brain radiation ... Decadron) while you are getting radiation to the brain. It may make you hungrier, cause leg swelling ...

  17. Epilepsy - children - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000127.htm Epilepsy in children - discharge To use the sharing features ... this page, please enable JavaScript. Your child has epilepsy . People with epilepsy have seizures. A seizure is ...

  18. Epilepsy or seizures - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000128.htm Epilepsy or seizures - discharge To use the sharing features on this page, please enable JavaScript. You have epilepsy . People with epilepsy have seizures. A seizure is ...

  19. Multiple sclerosis - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000129.htm Multiple sclerosis - discharge To use the sharing features on this ... Your doctor has told you that you have multiple sclerosis (MS). This disease affects the brain and spinal ...

  20. Pneumonia - adults - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000017.htm Pneumonia in adults - discharge To use the sharing features on this page, please enable JavaScript. You have pneumonia, which is an infection in your lungs. In ...

  1. Pneumonia - children - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000011.htm Pneumonia in children - discharge To use the sharing features ... this page, please enable JavaScript. Your child has pneumonia, which is an infection in the lungs. In ...

  2. Hip fracture - discharge

    Science.gov (United States)

    ... Philadelphia, PA: Elsevier; 2017:chap 55. Read More Broken bone Hip fracture surgery Hip pain Leg MRI scan Osteoporosis - overview Patient Instructions Getting your home ready - knee or hip surgery Osteomyelitis - discharge Review ...

  3. Electric field in an AC dielectric barrier discharge overlapped with a nanosecond pulse discharge

    Science.gov (United States)

    Goldberg, Benjamin M.; Shkurenkov, Ivan; Adamovich, Igor V.; Lempert, Walter R.

    2016-08-01

    The effect of ns discharge pulses on the AC barrier discharge in hydrogen in plane-to-plane geometry is studied using time-resolved measurements of the electric field in the plasma. The AC discharge was operated at a pressure of 300 Torr at frequencies of 500 and 1750 Hz, with ns pulses generated when the AC voltage was near zero. The electric field vector is measured by ps four-wave mixing technique, which generates coherent IR signal proportional to the square of electric field. Absolute calibration was done using an electrostatic (sub-breakdown) field applied to the discharge electrodes, when no plasma was generated. The results are compared with one-dimensional kinetic modeling of the AC discharge and the nanosecond pulse discharge, predicting behavior of both individual micro-discharges and their cumulative effect on the electric field distribution in the electrode gap, using stochastic averaging based on the experimental micro-discharge temporal probability distribution during the AC period. Time evolution of the electric field in the AC discharge without ns pulses, controlled by a superposition of random micro-discharges, exhibits a nearly ‘flat top’ distribution with the maximum near breakdown threshold, reproduced quite well by kinetic modeling. Adding ns pulse discharges on top of the AC voltage waveform changes the AC discharge behavior in a dramatic way, inducing transition from random micro-discharges to a more regular, near-1D discharge. In this case, reproducible volumetric AC breakdown is produced at a well-defined moment after each ns pulse discharge. During the reproducible AC breakdown, the electric field in the plasma exhibits a sudden drop, which coincides in time with a well-defined current pulse. This trend is also predicted by the kinetic model. Analysis of kinetic modeling predictions shows that this effect is caused by large-volume ionization and neutralization of surface charges on the dielectrics by ns discharge pulses. The present

  4. Comparison of the Effect of Ondansetrone - Dexamethasone, Dexamethasone – Metoclopeamide and Ondansetron - Normal Saline in Decreasing Post Operative Nausa and Vomitting (PONV after Middle Ear Surgery

    Directory of Open Access Journals (Sweden)

    Haddadi Soudabeh

    2009-09-01

    Full Text Available Background: The incidence of post-operative nausea and vomitting (PONV is increased after middle ear surgery and it may complicate and interact with reconstruction after surgery, so prevention and treatment of these complications are necessary.The aim of this study was to evaluate the efficacy of anti-emetic combinations in decreasing the PONV after middle ear surgery.Materials and methods: This double blind clinical trial was carried out during 2007-2008 on 111 patients of 15-45 years old with ASA I-II who were candidates for elective middle ear surgery under general anesthesia. The patients were divided into three groups. Patients in the ON group received Ondansetrone 0.1mg/kg + Nacl 0.9% 2cc, OD group received Ondansetrone 0.1mg/kg + Dexamethasone 0.15mg/kg and MD group received Dexamethasone 0.15mg/kg+ Metoclopramide 0.15mg/kg intravenously just before the end of surgery. The patients were evaluated for nausea, vomiting, need of anti-emetic drugs and drug dosage in recovery, 1-6, 6-12 and 12-24 hours after operation and then all data were statistically analyzed by SPSS software, Chi-square, ANOVA and t- Test. P<0.05 was significant.Results: There were no significant differences among three groups in age and sex. The incidence of PONV among 3 groups was not significantly different during 24 hours after operation. (P=0.271 but the incidence of PONV in the first six hours was different among 3 groups (P=0.007 (ON: 8.1%, OD: 0%, MD: 21.6%. Also Metoclopramide consumption was significant between three groups. Conclusion: This study showed that the need to anti-emetic drugs in first 6 hours was the least in OD group, but the difference in the incidence of PONV was not significant otherwise.

  5. STAR-concept: method for the definition and generation of computer-based systems to support the operator during normal and disturbed plant situations

    International Nuclear Information System (INIS)

    Felkel, L.; Roggenbauer, H.

    1983-01-01

    The paper describes a variety of functions to improve man-machine communication in nuclear power plants by advanced use of process computers. Special functions of interest here are: computerized operational manual; post trip analysis; alarm reduction; disturbance analysis and surveillance; and improved plant information processing, retrieval and display. All these functions use complex combinations of plant signals. The combinations (discrete process models) have to be described in a homogenous and formal way. The methodology used as well as the functions and examples are given. Experience from a pilot application in a nuclear power plant is also reported

  6. A Study on the improvement of Paldang dam discharge evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Song, Young Chul; Kim, Chong Hak; Lee, Dae Soo [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center; Lee, Won Hwan; Cho, Won Chul; Heo, Jun Haeng [Yonsei Univ., Seoul (Korea, Republic of)

    1995-12-31

    Besides the original purpose of electric power generation, the Paldang dam plays such important roles as flood control and water supply in the Han river. However, significant drawdown of the downstream water level since 1973 has caused considerable differences between the real discharges and the estimated values currently in use. This study was performed to improve discharge evaluation method and to provide new discharge table appropriate for the changed condition. Through the physical model tests assisted by numerical test, the discharge equations were modified, the discharge table was revised for steady and unsteady flow conditions, but the gate operation rules proved reasonable and remained unchanged. (author). 81 refs., 166 figs.

  7. The influence of impurities on the discharge behaviour in SPICA

    International Nuclear Information System (INIS)

    Meer, A.F.G. van der.

    1981-10-01

    Discharges in the screw pinch SPICA can be produced in a small range of filling pressures and bias field values. The experimentally observed lower limit of 6 mtorr for the filling pressure is explained by the onset of MHD instabilities and by imperfect implosion at low values of the filling pressure at high values of the bias field. In the accessible parameter regime, discharges can be produced with densities of the order of 5x10 21 m -3 and temperatures between 30 and 80 eV, which show gross stability for 200 μs, albeit not reproducible. In this density and temperature range discharges can easily become dominated by energy losses due to impurity radiation. An investigation of the temperature decay and the impurity concentration shows that, in spite of the quartz liner, this is not the case under normal operating conditions and that the energy containment time is of the order of 200 μs. The temperature decay rate, measured by means of Thomson scattering, is only 0.15 eV/μs, whereas from the intensity ratio of the 15.0 nm 2s 2 S - 3p 2 p 0 and the 103.2 nm 2s 2 S - 2p 2 P 0 OVI emission lines a decay rate of 0.3 eV/μs is derived. From absolute intensity measurements an oxygen concentration is derived. Besides oxygen, also silicon and nitrogen are present in the discharge. The nitrogen concentration that follows from absolute intensity measurements is in fair agreement with estimates based on an analysis of the background gas. The silicon concentration has not been measured directly, but it is estimated to be less than half the oxygen concentration since the wall material is quartz (SiO 2 ) and part of the oxygen originates from the background gas, mainly as a constituent of water vapour

  8. Discharge lamp technologies

    Energy Technology Data Exchange (ETDEWEB)

    Dakin, J. [GE Lighting, Cleveland, OH (United States)

    1994-12-31

    This talk is an overview of discharge lamp technology commonly employed in general lighting, with emphasis on issues pertinent to lighting for plant growth. Since the audience is primarily from the plant growth community, and this begins the light source part of the program, we will start with a brief description of the discharge lamps. Challenges of economics and of thermal management make lamp efficiency a prime concern in controlled environment agriculture, so we will emphasize science considerations relating to discharge lamp efficiency. We will then look at the spectra and ratings of some representative lighting products, and conclude with a discussion of technological advance. A general overview of discharge lighting technology can be found in the book of Waymouth (1971). A recent review of low pressure lighting discharge science is found in Dakin (1991). The pioneering paper of Reiling (1964) provides a good introduction to metal halide discharges. Particularly relevant to lighting for plant growth, a recent and thorough treatment of high pressure Na lamps is found in the book by deGroot and vanVliet (1986). Broad practical aspects of lighting application are thoroughly covered in the IES Lighting Handbook edited by Kaufman (1984).

  9. Dark current studies on a normal-conducting high-brightness very-high-frequency electron gun operating in continuous wave mode

    Directory of Open Access Journals (Sweden)

    R. Huang

    2015-01-01

    Full Text Available We report on measurements and analysis of a field-emitted electron current in the very-high-frequency (VHF gun, a room temperature rf gun operating at high field and continuous wave (CW mode at the Lawrence Berkeley National Laboratory (LBNL. The VHF gun is the core of the Advanced Photo-injector Experiment (APEX at LBNL, geared toward the development of an injector for driving the next generation of high average power x-ray free electron lasers. High accelerating fields at the cathode are necessary for the high-brightness performance of an electron gun. When coupled with CW operation, such fields can generate a significant amount of field-emitted electrons that can be transported downstream the accelerator forming the so-called “dark current.” Elevated levels of a dark current can cause radiation damage, increase the heat load in the downstream cryogenic systems, and ultimately limit the overall performance and reliability of the facility. We performed systematic measurements that allowed us to characterize the field emission from the VHF gun, determine the location of the main emitters, and define an effective strategy to reduce and control the level of dark current at APEX. Furthermore, the energy spectra of isolated sources have been measured. A simple model for energy data analysis was developed that allows one to extract information on the emitter from a single energy distribution measurement.

  10. Air-cooled fast discharge resistors for ITER magnets

    International Nuclear Information System (INIS)

    Tanchuk, Victor; Grigoriev, Sergey; Lokiev, Vladimir; Roshal, Alexander; Song, Inho; Buzykin, Oleg

    2011-01-01

    The ITER superconducting magnets will store up to 50 GJ of magnetic energy per operation cycle. In case of coil quench the energy stored in the coils must be extracted rapidly with a time constant from 7.5 to 14 s. It will be achieved by fast discharge resistors (FDR) normally bridged by circuit breakers and inserted in series with the superconducting coils. The fast discharge of the coils results practically in adiabatic heating of the resistive elements up to 200-300 deg. C. The resistors need to be cooled to the initial temperature over 6-8 h. Natural air circulation is proposed as a cooling method. In order to simulate the temperature response of the resistors to energy released in the resistive plates and to demonstrate their cooling capability within the required time by natural air circulation the numerical model of the resistor cooling circuit has been developed. As the calculations have shown, the developed FDR cooling system based on cooling by natural air circulation is capable of providing the required temperature operation regime of FDRs, but the supply channels are to be optimized so that the cooling time does not exceed the permissible one.

  11. Pursuing Normality

    DEFF Research Database (Denmark)

    Madsen, Louise Sofia; Handberg, Charlotte

    2018-01-01

    BACKGROUND: The present study explored the reflections on cancer survivorship care of lymphoma survivors in active treatment. Lymphoma survivors have survivorship care needs, yet their participation in cancer survivorship care programs is still reported as low. OBJECTIVE: The aim of this study...... implying an influence on whether to participate in cancer survivorship care programs. Because of "pursuing normality," 8 of 9 participants opted out of cancer survivorship care programming due to prospects of "being cured" and perceptions of cancer survivorship care as "a continuation of the disease...

  12. X-ray pre-ionized molecular fluorine laser with a large discharge cross-section

    NARCIS (Netherlands)

    Bastiaens, Hubertus M.J.; Peters, P.J.M.; Witteman, W.J.

    1997-01-01

    High energy extraction from UV pre-ionized molecular fluorine lasers is hampered by the short period of discharge stability and the spatial inhomogeneity of the discharge. So far stable discharge operation is reported for small discharge cross sections with an area less than 0.8 cm2 and efficiencies

  13. Technological ion sources based on the vacuum arc discharge

    CERN Document Server

    Bugaev, S P; Oks, E M; Yushkov, G Y; Shchanin, P M; Braun, Y

    2001-01-01

    The Titan service ion sources are designed to generate wide-aperture high-current ion beams of gases or metals, as well as, mixed two-component gas and metal ion beams with the controllable ratio of components in a beam. This possibility is achieved via integration of two discharge systems in a source discharge system. To generate metal ions one uses a vacuum, arc discharge, while gas ions are generated by a low pressure contracted arc discharge with cold cathodes. The paper describes operation of these sources, their design, technical characteristics, peculiarities of their operation and application fields

  14. Operant conditioning of the soleus H-reflex does not induce long-term changes in the gastrocnemius H-reflexes and does not disturb normal locomotion in humans.

    Science.gov (United States)

    Makihara, Yukiko; Segal, Richard L; Wolpaw, Jonathan R; Thompson, Aiko K

    2014-09-15

    In normal animals, operant conditioning of the spinal stretch reflex or the H-reflex has lesser effects on synergist muscle reflexes. In rats and people with incomplete spinal cord injury (SCI), soleus H-reflex operant conditioning can improve locomotion. We studied in normal humans the impact of soleus H-reflex down-conditioning on medial (MG) and lateral gastrocnemius (LG) H-reflexes and on locomotion. Subjects completed 6 baseline and 30 conditioning sessions. During conditioning trials, the subject was encouraged to decrease soleus H-reflex size with the aid of visual feedback. Every sixth session, MG and LG H-reflexes were measured. Locomotion was assessed before and after conditioning. In successfully conditioned subjects, the soleus H-reflex decreased 27.2%. This was the sum of within-session (task dependent) adaptation (13.2%) and across-session (long term) change (14%). The MG H-reflex decreased 14.5%, due mainly to task-dependent adaptation (13.4%). The LG H-reflex showed no task-dependent adaptation or long-term change. No consistent changes were detected across subjects in locomotor H-reflexes, EMG activity, joint angles, or step symmetry. Thus, in normal humans, soleus H-reflex down-conditioning does not induce long-term changes in MG/LG H-reflexes and does not change locomotion. In these subjects, task-dependent adaptation of the soleus H-reflex is greater than it is in people with SCI, whereas long-term change is less. This difference from results in people with SCI is consistent with the fact that long-term change is beneficial in people with SCI, since it improves locomotion. In contrast, in normal subjects, long-term change is not beneficial and may necessitate compensatory plasticity to preserve satisfactory locomotion. Copyright © 2014 the American Physiological Society.

  15. The Effect of Phase-to-earth Faults on the Operating Conditions of a Separated 110 kV Grid Normally Operated with Effectively Earthed Neutral, and Temporarily Supplied from a Compensated 110 kV Grid

    Directory of Open Access Journals (Sweden)

    Wilhelm Rojewski

    2015-06-01

    Full Text Available The paper discusses the interoperability of the German compensated 110 kV grid and the Polish effectively earthed 110 kV grid. It is assumed that an area of one grid, separated from its power system, will be temporarily supplied from the other grid in its normal regime. Reference is made to the risks associated with phase-to-earth faults in grids so interconnected. Particular attention is paid to the working conditions of surge arresters and voltage transformers in the Polish 110 kV grid deprived of its neutral earthing when supplied from the German grid.

  16. Ginsenoside Rb1 Attenuates Agonist-Induced Contractile Response via Inhibition of Store-Operated Calcium Entry in Pulmonary Arteries of Normal and Pulmonary Hypertensive Rats

    Directory of Open Access Journals (Sweden)

    Rui-Xing Wang

    2015-03-01

    Full Text Available Background: Pulmonary hypertension (PH is characterized by sustained vasoconstriction, enhanced vasoreactivity and vascular remodeling, which leads to right heart failure and death. Despite several treatments are available, many forms of PH are still incurable. Ginsenoside Rb1, a principle active ingredient of Panax ginseng, exhibits multiple pharmacological effects on cardiovascular system, and suppresses monocrotaline (MCT-induced right heart hypertrophy. However, its effect on the pulmonary vascular functions related to PH is unknown. Methods: We examined the vasorelaxing effects of ginsenoside Rb1 on endothelin-1 (ET-1 induced contraction of pulmonary arteries (PAs and store-operated Ca2+ entry (SOCE in pulmonary arterial smooth muscle cells (PASMCs from chronic hypoxia (CH and MCT-induced PH. Results: Ginsenoside Rb1 elicited concentration-dependent relaxation of ET-1-induced PA contraction. The vasorelaxing effect was unaffected by nifedipine, but abolished by the SOCE blocker Gd3+. Ginsenoside Rb1 suppressed cyclopiazonic acid (CPA-induced PA contraction, and CPA-activated cation entry and Ca2+ transient in PASMCs. ET-1 and CPA-induced contraction, and CPA-activated cation entry and Ca2+ transients were enhanced in PA and PASMCs of CH and MCT-treated rats; the enhanced responses were abolished by ginsenoside Rb1. Conclusion: Ginsenoside Rb1 attenuates ET-1-induced contractile response via inhibition of SOCE, and it can effectively antagonize the enhanced pulmonary vasoreactivity in PH.

  17. Transforming Normal Programs by Replacement

    NARCIS (Netherlands)

    Bossi, Annalisa; Pettorossi, A.; Cocco, Nicoletta; Etalle, Sandro

    1992-01-01

    The replacement transformation operation, already defined in [28], is studied wrt normal programs. We give applicability conditions able to ensure the correctness of the operation wrt Fitting's and Kunen's semantics. We show how replacement can mimic other transformation operations such as thinning,

  18. UK strategy for radioactive discharges 2001-2020. Consultation document

    International Nuclear Information System (INIS)

    2000-06-01

    This consultation draft of a strategy for radioactive discharges describes how the United Kingdom (UK) will implement the agreements reached at the 1998 Ministerial meeting of the OSPAR Commission, with regard to radioactive substances. It also provides a policy base for future reviews of discharge authorisations by the regulatory bodies and for strategic planning by the nuclear operators. The strategy sets a framework for radioactive discharges from UK installations over the next twenty years. Its aims are: progressive and substantial reductions in radioactive discharges from the UK as a whole and from each of the main sectors responsible for such discharges; progressive reduction of human exposure to ionising radiation resulting from radioactive discharges, so that no member of the general public in the UK will be exposed to a dose of more than 0.02 mSv a year, as a result of authorised radioactive discharges made from 2020 onwards; progressive reductions in concentrations of radionuclides in the marine environment resulting from radioactive discharges, such that by 2020 they add close to zero to historic levels. The scope of the UK strategy encompasses radioactive discharges from nuclear licensed sites, defence activities and other nuclear and non-nuclear sources of radioactive discharges. It covers both liquid and aerial discharges, although it is assumed that in general liquid discharges will have the largest and most measurable effects in the marine environment

  19. Deterministic dynamics of plasma focus discharges

    International Nuclear Information System (INIS)

    Gratton, J.; Alabraba, M.A.; Warmate, A.G.; Giudice, G.

    1992-04-01

    The performance (neutron yield, X-ray production, etc.) of plasma focus discharges fluctuates strongly in series performed with fixed experimental conditions. Previous work suggests that these fluctuations are due to a deterministic ''internal'' dynamics involving degrees of freedom not controlled by the operator, possibly related to adsorption and desorption of impurities from the electrodes. According to these dynamics the yield of a discharge depends on the outcome of the previous ones. We study 8 series of discharges in three different facilities, with various electrode materials and operating conditions. More evidence of a deterministic internal dynamics is found. The fluctuation pattern depends on the electrode materials and other characteristics of the experiment. A heuristic mathematical model that describes adsorption and desorption of impurities from the electrodes and their consequences on the yield is presented. The model predicts steady yield or periodic and chaotic fluctuations, depending on parameters related to the experimental conditions. (author). 27 refs, 7 figs, 4 tabs

  20. Modification of various metals by volume discharge in air atmosphere

    Science.gov (United States)

    Shulepov, Mikhail A.; Erofeev, Mikhail V.; Oskomov, Konstantin V.; Tarasenko, Victor F.

    2015-12-01

    The results of the modification of stainless steel, niobium and titanium by volume discharge induced by a beam of runaway electrons in air under normal pressure are presented. Changes in the chemical composition of the surface layers of metal by the action of the discharge, structural changes and changes of hardness were studied. It has been found that the concentration of oxygen and carbon in the surface layers of the samples depend on the number of discharge pulses. The aim of this work is to find possible application of this type of discharge in science and industrial production.

  1. Oil based mud discharges

    International Nuclear Information System (INIS)

    Tiesma, R.

    1996-01-01

    The intensive use of oil based muds by the offshore oil and gas industry during the 1980s has caused considerable contamination around drilling sites. A recent investigation on the Norwegian continental shelf indicates that the situation is much worse than previously thought. This material suggests that oil pollution of this kind could be damaging the North Sea's endangered fish stocks, including cod, haddock and plaice. The amount of oil discharged in the UK sector is many times higher than in the other sectors, suggesting that the problem there may be even more serious. The amount discharged in the Dutch and Norwegian sectors are comparable. (author)

  2. [Diagnosis of vaginal discharge].

    Science.gov (United States)

    Böcher, Sidsel; Helmig, Rikke Bek; Arpi, Magnus; Bjerrum, Lars

    2018-01-15

    Changes in vaginal discharge are often caused by imbalance in the vaginal microflora, and laboratory testing is usually of little use, as most microbes detected are commensals. In-office diagnosis in general practice using wet mount microscopy and Amsel criteria is helpful and often sufficient to ensure correct diagnosis and treatment. Laboratory testing of vaginal discharge should only be performed, if sexually transmitted disease is suspected, if there is treatment failure or inconclusive wet mount prior to gynaecological surgery, and in pregnant women with recurrent miscarriage or preterm birth.

  3. Red herring vaginal discharge.

    Science.gov (United States)

    Lee, Jun Hee; Pringle, Kirsty; Rajimwale, Ashok

    2013-09-18

    Labial hair tourniquet syndrome is a rare condition that can be easily misdiagnosed and ultimately lead to irreversible damage. An 11-year-old premenarche girl presented with a 5-day history of pain and swelling in the labia with associated vaginal discharge. The general practitioner treated her with clotrimazole without improvement. On examination, there was an oedematous swelling of the right labia with a proximal hair tourniquet. Local anaesthetic was applied and the hair removed with forceps. There was instant relief of pain and the discharge stopped within 24 h. The patient was sent home with a course of antibiotics.

  4. Monitor For Electrical-Discharge Machining

    Science.gov (United States)

    Burley, Richard K.

    1993-01-01

    Circuit monitors electrical-discharge-machining (EDM) process to detect and prevent abnormal arcing, which can produce unacceptable "burn" marks on workpiece. When voltage between EDM electrode and workpiece behaves in manner indicative of abnormal arcing, relay made to switch off EDM power, which remains off until operator attends to EDM setup and resets monitor.

  5. On commuting operator exponentials, II

    Indian Academy of Sciences (India)

    where N is an unbounded normal operator and M is a bounded normal operator in the. Hilbert space. Keywords. Self-adjoint and normal operator; commuting normal operator exponent- ials; Borel functional calculus. 1. Introduction. Let E be a complex Hilbert space and let B(E) be the algebra of bounded linear operators.

  6. Discharges from nuclear power stations

    International Nuclear Information System (INIS)

    1991-02-01

    HM Inspectorate of Pollution commissioned, with authorising responsibilities in England and Wales, a study into the discharges of radioactive effluents from Nuclear Power Stations. The study considered arisings from nuclear power stations in Europe and the USA and the technologies to treat and control the radioactive discharges. This report contains details of the technologies used at many nuclear power stations to treat and control radioactive discharges and gives, where information was available, details of discharges and authorised discharge limits. (author)

  7. Simulation of nonstationary phenomena in atmospheric-pressure glow discharge

    International Nuclear Information System (INIS)

    Korolev, Yu. D.; Frants, O. B.; Nekhoroshev, V. O.; Suslov, A. I.; Kas’yanov, V. S.; Shemyakin, I. A.; Bolotov, A. V.

    2016-01-01

    Nonstationary processes in atmospheric-pressure glow discharge manifest themselves in spontaneous transitions from the normal glow discharge into a spark. In the experiments, both so-called completed transitions in which a highly conductive constricted channel arises and incomplete transitions accompanied by the formation of a diffuse channel are observed. A model of the positive column of a discharge in air is elaborated that allows one to interpret specific features of the discharge both in the stationary stage and during its transition into a spark and makes it possible to calculate the characteristic oscillatory current waveforms for completed transitions into a spark and aperiodic ones for incomplete transitions. The calculated parameters of the positive column in the glow discharge mode agree well with experiment. Data on the densities of the most abundant species generated in the discharge (such as atomic oxygen, metastable nitrogen molecules, ozone, nitrogen oxides, and negative oxygen ions) are presented.

  8. Simulation of nonstationary phenomena in atmospheric-pressure glow discharge

    Science.gov (United States)

    Korolev, Yu. D.; Frants, O. B.; Nekhoroshev, V. O.; Suslov, A. I.; Kas'yanov, V. S.; Shemyakin, I. A.; Bolotov, A. V.

    2016-06-01

    Nonstationary processes in atmospheric-pressure glow discharge manifest themselves in spontaneous transitions from the normal glow discharge into a spark. In the experiments, both so-called completed transitions in which a highly conductive constricted channel arises and incomplete transitions accompanied by the formation of a diffuse channel are observed. A model of the positive column of a discharge in air is elaborated that allows one to interpret specific features of the discharge both in the stationary stage and during its transition into a spark and makes it possible to calculate the characteristic oscillatory current waveforms for completed transitions into a spark and aperiodic ones for incomplete transitions. The calculated parameters of the positive column in the glow discharge mode agree well with experiment. Data on the densities of the most abundant species generated in the discharge (such as atomic oxygen, metastable nitrogen molecules, ozone, nitrogen oxides, and negative oxygen ions) are presented.

  9. Heart bypass surgery - discharge

    Science.gov (United States)

    ... trouble with short-term memory or feel confused ("fuzzy-headed") Be tired or not have much energy ... or a fever over 101°F (38.3°C). Alternative Names Off-pump coronary artery bypass - discharge; ...

  10. Electrical Discharge Machining.

    Science.gov (United States)

    Montgomery, C. M.

    The manual is for use by students learning electrical discharge machining (EDM). It consists of eight units divided into several lessons, each designed to meet one of the stated objectives for the unit. The units deal with: introduction to and advantages of EDM, the EDM process, basic components of EDM, reaction between forming tool and workpiece,…

  11. MANAGEMENT OF VAGINAL DISCHARGE

    African Journals Online (AJOL)

    Enrique

    , an oral antifungal should be used weekly, e.g. 100 mg flucona- zole.7. The discharge of candidiasis is curd- like and adherent due to direct hyphal invasion of epithelial tissues resulting in erythema of the vaginal epithelium. Clinical diagnosis ...

  12. Ulcerative colitis - discharge

    Science.gov (United States)

    ... doctor - child Diarrhea - what to ask your health care provider - adult Enteral nutrition - child - managing problems Gastrostomy feeding tube - bolus Ileostomy and your child Ileostomy and your diet Ileostomy - caring for your stoma Ileostomy - discharge Jejunostomy feeding tube Living with your ...

  13. Crohn disease - discharge

    Science.gov (United States)

    ... doctor - child Diarrhea - what to ask your health care provider - adult Enteral nutrition - child - managing problems Gastrostomy feeding tube - bolus Ileostomy and your child Ileostomy and your diet Ileostomy - caring for your stoma Ileostomy - discharge Jejunostomy feeding tube Living with your ...

  14. Cosmetic breast surgery - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000273.htm Cosmetic breast surgery - discharge To use the sharing features on this ... Editorial team. Related MedlinePlus Health Topics Plastic and Cosmetic Surgery Browse the Encyclopedia A.D.A.M., Inc. ...

  15. Combatting operational pollution from offshore petroleum activities: international legal regime

    International Nuclear Information System (INIS)

    Vinogradov, S.V.; Wagner, J.P.

    1997-01-01

    Existing global and regional rules and regulations, and regulatory trends, aimed at curbing pollution associated with the normal operation of offshore oil and gas installations are assessed. The designation 'operational pollution' is used to cover a variety of discharges including: oil produced in water; contaminated drill cuttings and muds; sewage; garbage; deck drainage; naturally occurring materials such as radionuclides, heavy metals and aromatics; atmospheric emissions, principally CO 2 , SO x , NO x , CH 4 and volatile organic compounds. The main focus of regulatory attention at present is platform drainage, offshore processing drainage, production water discharge, and displacement discharge. The legal framework considered extends to the appropriate global and regional treaties, ''soft law'' instruments and recommendations. (UK)

  16. Range of the radiation monitor for the rigid vent of primary containment during normal and emergency operation for a BWR-5 in Laguna Verde; Rango del monitor de radiacion para el venteo rigido de la contencion primaria durante operacion normal y emergencia para un reactor BWR-5 en Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Tijerina S, F.; Pozos S, A. M.; Cabrera U, S.; Mata A, J. A.; Sandoval V, S.; Ovando C, R.; Vargas A, A.; Gallardo R, I.; Cruz G, M.; Amador C, C., E-mail: francisco.tijerina@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Subgerencia de Ingenieria, Km 44.5 Carretera Cardel-Nautla, 91476 Laguna Verde, Alto Lucero, Veracruz (Mexico)

    2014-10-15

    The earthquake followed by a tsunami, happened in March, 2011 in the coasts of oriental Japan, caused damages in the nuclear power plants 1 at 4 of Fukushima Daiichi leading to damage of the fuel in three of the reactors and to the radiation liberation to the exterior. As consequence of those events, the regulations requires that the power plants with Primary Containment type Mark I and II evaluate to have a system of rigid vent with a monitoring equipment of radiation effluents. The present work covers the rigid vent of diameter 12 of the Primary Containment, type Mark-II, of nuclear power plant of Laguna Verde in conditions of severe accident and normal operation, low regime of Extended Power Up rate (EPU - 2317 MWt), using the codes MAAP3B, MICROSHILED 5.05 and the Bardach Black Boxes methodology. As a result the measurement range of the radiation monitor that is required for monitoring the gassy liberation to the atmosphere was determined. The conclusion is that the superior limit of the range of the radiation meter during a Severe Accident is of 8.55 E + 05 R/h (8.55 E + 08 m R/h) and the superior limit in normal operation of 1.412 E-11 at 2.540 E-7 R/h (1.412 E-14 at 2.540 E-10 m R/h). (Author)

  17. Evaluation of common organisms causing vaginal discharge.

    Science.gov (United States)

    Khan, Shazia A; Amir, Fauzia; Altaf, Shagufta; Tanveer, Raazia

    2009-01-01

    Vaginal discharge is very common problem among females. Alteration in balance of normal vaginal organisms can cause the overgrowth of the bacteria that creates vaginal discharge. It is common among sexually active women yet there still remain gaps in our knowledge of this infectious disorder. To evaluate the frequency of bacterial vaginosis (BV), vaginal candidiasis (VC), vaginal trichomoniasis and Group B streptococcus in women complaining of vaginal discharge in our setup. A total of 100 women of reproductive age group with the complaint of vaginal discharge were included in the study. After filling proforma patients were examined by speculum examination and two high vaginal swabs (HVS) were collected aseptically from each patient. One swab was used for making wet mount for clue cells, pus cells and for motility of Trichomonas vaginalis. The other swab was used to check pH and Amine test. The growth was confirmed by Gram staining in each case. Gardnerrella vaginalis were isolated in 28%, Group B streptococcus in 5% and T. vaginolis in 4% of women. Gardnerella vaginalis causing BV is the most common cause of vaginal discharge in otherwise healthy women of reproductive age group in our setup.

  18. Excimer Lasers With Capacitively Excited Tubular Discharges

    Science.gov (United States)

    Eichler, Hans J.; Herweg, Helmut; de la Rosa, Jose

    1989-04-01

    The excitation of excimer lasers in tubular discharges results in simple and compact devices needing no preionization. Optical output energies are in the millijoule range. We investigated XeF, KrF and ArF lasers for various operating conditions. The lasers consist of capillary glass tubes with two internal electrodes at the ends and an aluminium-foil wrapped around the tube as capacitive electrode. A maximum output energy of 0.3 mJ has been achieved for the XeF laser. The good quality of the discharge is indicated by the observation of spontaneous mode locking. The detailed study of the discharge for different polarities of the electrodes has shown that efficient operation with a high gas lifetime can be obtained by a purely capacitively excited discharge. A gas lifetime of about 10,000 pulses for 3 litres gas mixture has been observed. Using a two stage Marx generator to generate 100 kV excitation voltage a maximum output energy of 0.7 mJ was obtained for a gas mixture of Kr, F2 and He with an efficiency of 0.17%. The KrF laser operates also without the buffer gas. Laser action in ArF has been achieved with 15 μJ pulse energy and 10 ns duration.

  19. Recurrent, purulent vaginal discharge associated with longstanding presence of a foreign body and vaginal stenosis.

    Science.gov (United States)

    Simon, Deborah A; Berry, Scott; Brannian, John; Hansen, Keith

    2003-12-01

    A 13-year-old presented with malodorous, purulent, vaginal discharge following each menses for the last three months since menarche. This discharge resolved following antibiotic therapy but recurred with each menses. On exam, the patient was found to have a blind ending vagina with a small, midline perforation. Ultrasound and MRI examinations done prior to surgery did not identify the vaginal foreign body. She was taken to the operating room for examination under anesthesia and vaginoscopy. During surgery this area was found to be comprised of dense adhesions which nearly obliterated the distal vagina. The vaginal adhesions were lysed and a plastic foreign body was discovered in the upper vagina. After removing the foreign body the superior vagina was undermined, pulled down, and sutured to normal inferior vagina. A Mentor mold was placed in the vagina to maintain patency.

  20. Vessel Sewage Discharges: No-Discharge Zones (NDZs)

    Science.gov (United States)

    States may petition the EPA to establish areas, called no discharge zones (NDZs), where vessel sewage discharges are prohibited. This page describes how NDZs are designated, the types of designations, who enforces them, and how to comply.

  1. Low-field helicon discharges

    Science.gov (United States)

    Chen, F. F.; Jiang, X.; Evans, J. D.; Tynan, G.; Arnush, D.

    1997-05-01

    Operation of helicon discharges at magnetic fields B0 below 100 G is of interest for plasma etching and deposition reactors if high ion flux can be maintained with reduced field requirements. The theory of coupled helicon and Trivelpiece - Gould modes is summarized for uniform B0. Initial results from two experiments are reported. The first has a single 5 cm diameter tube with B0=0-100G injecting plasma into a field-free region. The second contains a two-dimensional array of seven such tubes covering a large area. Densities and density profiles are measured for various fields, RF powers and gas pressures. The highest density generally occurs at zero field. Because of the non-uniformity in B0, direct comparison with theory cannot yet be made.

  2. Relative K-homology and normal operators

    DEFF Research Database (Denmark)

    Manuilov, Vladimir; Thomsen, Klaus

    2009-01-01

    -term exact sequence which generalizes the excision six-term exact sequence in the first variable of KK-theory. Subsequently we investigate the relative K-homology which arises from the group of relative extensions by specializing to abelian $C^*$-algebras. It turns out that this relative K-homology carries...

  3. GASEOUS DISCHARGE DEVICE

    Science.gov (United States)

    Gow, J.D.

    1961-01-10

    An extremely compact two-terminal gaseous discharge device is described that is capable of producing neutrons in copious quantities, relatively high energy ions, intense x rays, and the like. Principal novelty resides in the provision of a crossed electric-magnetic field region in the discharge envelope that traps electrons and accelerates them to very high energies to provide an intense ionizing medium adjacent the anode of the device for ionizing gas therein with extremely high efficiency. In addition, the crossed-field trapping region holds the electrons close to the anode whereby the acceleration of ions to the cathode is not materially effected by the electron sheath and the ions assume substantially the full energy of the anodecathode potential drop. (auth)

  4. Discharge pulse phenomenology

    Science.gov (United States)

    Frederickson, A. R.

    1985-01-01

    A model was developed which places radiation induced discharge pulse results into a unified conceptual framework. Only two phenomena are required to interpret all space and laboratory results: (1) radiation produces large electrostatic fields inside insulators via the trapping of a net space charge density; and (2) the electrostatic fields initiate discharge streamer plasmas similar to those investigated in high voltage electrical insulation materials; these streamer plasmas generate the pulsing phenomena. The apparent variability and diversity of results seen is an inherent feature of the plasma streamer mechanism acting in the electric fields which is created by irradiation of the dielectrics. The implications of the model are extensive and lead to constraints over what can be done about spacecraft pulsing.

  5. Application of MEVVA discharge to material surface modification

    International Nuclear Information System (INIS)

    Gao Yu; Geng Man; Huang Yuming; Gong Xiaorong; Yu Yijun; Tang Deli; Tie Jun

    1996-01-01

    The authors describes some characteristics of the MEVVA discharge, the process of generating a cathode-arc plasma and the advantages of the MEVVA discharge compared with the kind of heating-vaporizing-ionizing source. Some practical parameters and the operating process of the MEVVA ion source as well as a plasma source with MEVVA discharge used in a PSII device are presented. Various plasmas having good-quality and high-performance are obtained with MEVVA discharges and have been widely used in sight-line processing and omnibearing ion implantation for material surface modification

  6. Study of electric discharges between moving electrodes in air

    International Nuclear Information System (INIS)

    Andreev, V. V.; Pichugin, Yu. P.; Telegin, V. G.; Telegin, G. G.

    2011-01-01

    A barrier electric discharge excited between a fixed electrode and a rotating electrode covered with a dielectric layer in atmospheric-pressure air is studied experimentally. A distinctive feature of this type of discharge is that it operates at a constant voltage between the electrodes. An advantage of the proposed method for plasma generation in the boundary layer of the rotating electrode (e.g., for studying the influence of plasma on air flows) is the variety of forms of the discharge and conditions for its initiation, simplicity of the design of the discharge system, and ease of its practical implementation

  7. Study of electric discharges between moving electrodes in air

    Energy Technology Data Exchange (ETDEWEB)

    Andreev, V. V.; Pichugin, Yu. P.; Telegin, V. G.; Telegin, G. G. [Chuvash State University (Russian Federation)

    2011-12-15

    A barrier electric discharge excited between a fixed electrode and a rotating electrode covered with a dielectric layer in atmospheric-pressure air is studied experimentally. A distinctive feature of this type of discharge is that it operates at a constant voltage between the electrodes. An advantage of the proposed method for plasma generation in the boundary layer of the rotating electrode (e.g., for studying the influence of plasma on air flows) is the variety of forms of the discharge and conditions for its initiation, simplicity of the design of the discharge system, and ease of its practical implementation.

  8. Monitoring of lightning discharge

    International Nuclear Information System (INIS)

    Grigor'ev, V.A.

    2001-01-01

    The paper presents a brief description of a lightning discharge recording system developed at the NPO 'Monitoring Techniques' under the direction of V.M. Moskolenko (Moscow). The system provides information about dangerous environmental occurrences such as tornados and hurricanes, making the forecast of extreme situations possible, especially in the areas of dangerous industries and objects. The created automatic system can be useful in solving the tasks relating to nuclear test monitoring. (author)

  9. The human discharge chain

    Science.gov (United States)

    Dudley, Scott C.; Heerema, Bret D.; Haaland, Ryan K.

    1997-06-01

    The common classroom demonstration of a human chain, charged by a Van de Graaff generator, and then discharged via the person at the end of the chain touching ground, is analyzed as a capacitor and resistor circuit model. The energy deposited in each person in the chain is determined. Further, the effect of increasing energy deposited in the person who touched ground, as the number of people in the chain is increased, is shown and quantified.

  10. Plasma Processing with a One Atmosphere Uniform Glow Discharge Plasma (OAUGDP)

    Science.gov (United States)

    Reece Roth, J.

    2000-10-01

    The vast majority of all industrial plasma processing is conducted with glow discharges at pressures below 10 torr. This has limited applications to high value workpieces as a result of the large capital cost of vacuum systems and the production constraints of batch processing. It has long been recognized that glow discharges would play a much larger industrial role if they could be operated at one atmosphere. The One Atmosphere Uniform Glow Discharge Plasma (OAUGDP) has been developed at the University of Tennessee Plasma Sciences Laboratory. The OAUGDP is non-thermal RF plasma with the time-resolved characteristics of a classical low pressure DC normal glow discharge. An interdisciplinary team was formed to conduct exploratory investigations of the physics and applications of the OAUGDP. This team includes collaborators from the UTK Textiles and Nonwovens Development Center (TANDEC) and the Departments of Electrical and Computer Engineering, Microbiology, Food Science and Technology, and Mechanical and Aerospace Engineering and Engineering Science. Exploratory tests were conducted on a variety of potential plasma processing and other applications. These include the use of OAUGDP to sterilize medical and dental equipment and air filters; diesel soot removal; plasma aerodynamic effects; electrohydrodynamic (EDH) flow control of the neutral working gas; increasing the surface energy of materials; increasing the wettability and wickability of fabrics; and plasma deposition and directional etching. A general overview of these topics will be presented.

  11. Determination of discharge authorizations for French basic nuclear installations 58 and public information

    International Nuclear Information System (INIS)

    Tabard, Laurence; Conte, Dorothee

    2013-01-01

    The determination of discharge authorized limits for a French nuclear site is initiated by the request of the operator, based on the maximum nuclear and chemical inventory that could be released during normal operating conditions, accompanied with justifications. Request and justifications are analyzed and discussed by the ASN and the IRSN, taking into account nuclear and chemical inventories expected inside BNI, current regulations (BNI specific regulation, environment code, public health code), operating feedback (release feedback for an operating BNI, feedback coming from other nuclear sites or installations, etc.) and best available technologies that can be used to treat liquid or gaseous waste before release. After taking into account potential suggestions coming from public information or public enquiry concerning the operator request, the discharge authorized limits are settled down in specific ASN prescriptions that have to be ratified by the State secretaries in charge of nuclear safety. The whole process runs through 2 or 3 years to be achieved. Communication has revealed to be quite an uneasy task, even for administrative procedures. This aspect is mostly tested while communicating about events. Consequences of this communication can hardly be foreseen because of multiple external parameters like: news on the front pages at the same moment; historic communication difficulties still in the public mind; technical vocabulary not easily understood; public fear of things being hidden; power of ecologist or non-governmental associations. (authors)

  12. Vaginal itching and discharge - child

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003159.htm Vaginal itching and discharge - child To use the sharing features on this ... problem in girls before the age of puberty. Vaginal discharge may also be present. The color, smell, and ...

  13. Spleen removal - open - adults - discharge

    Science.gov (United States)

    ... discharge; Spleen removal - adult - discharge References Poulose BK, Holzman MD. The spleen. In: Townsend CM, Beauchamp RD, ... provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, Medical Director, Brenda Conaway, Editorial ...

  14. Plasma Discharge Process in a Pulsed Diaphragm Discharge System

    Science.gov (United States)

    Duan, Jianjin; Hu, Jue; Zhang, Chao; Wen, Yuanbin; Meng, Yuedong; Zhang, Chengxu

    2014-12-01

    As one of the most important steps in wastewater treatment, limited study on plasma discharge process is a key challenge in the development of plasma applications. In this study, we focus on the plasma discharge process of a pulsed diaphragm discharge system. According to the analysis, the pulsed diaphragm discharge proceeds in seven stages: (1) Joule heating and heat exchange stage; (2) nucleated site formation; (3) plasma generation (initiation of the breakdown stage); (4) avalanche growth and plasma expansion; (5) plasma contraction; (6) termination of the plasma discharge; and (7) heat exchange stage. From this analysis, a critical voltage criterion for breakdown is obtained. We anticipate this finding will provide guidance for a better application of plasma discharges, especially diaphragm plasma discharges.

  15. ACL reconstruction - discharge

    Science.gov (United States)

    ... pillows. Place the pillows under your foot or calf muscle. This helps keep swelling down. Do this 4 ... medicine. You have swelling or pain in your calf muscle. Your foot or toes look darker than normal ...

  16. Knee arthroscopy - discharge

    Science.gov (United States)

    ... pillows. Place the pillows under your foot or calf muscle. This helps control swelling in your knee. For ... time. You have swelling or pain in your calf muscle. Your foot or toes look darker than normal ...

  17. Construction Of RF Power Supply For Glow Discharge Plasma

    International Nuclear Information System (INIS)

    Yunanto; Wibowo, Tono; Wirjoadi; Suryadi

    1996-01-01

    A RF power supply for glow discharge plasma has been made, so that on glow discharge reactor appear plasma that can be used make excellent matter. The device consisted of oscillator with LC tank circuit method, RF voltage amplifier, RF power amplifier and matching box. The device can be operated at 4 MHz to 13,56 MHz with optimum power output 30 watt. The RF power supply was coupled through matching box with glow discharge tube of capacitive method and working properly during 8 hours operation. The plasma stabilization has been tested and shows that stabilizations is about 2 x 10 - 2 / hour

  18. Continuous pile discharging machine

    International Nuclear Information System (INIS)

    Smith, P.P.

    1976-01-01

    A device for discharging cartridges from tubes under fluid pressure includes a cylindrical housing adapted to be seated in a leak-tight manner on the end of one of the tubes, a chute depending from the cylindrical housing near the end seated on the end of the tube, a rotatable piston having a wrench on the forward end thereof disposed in the cylindrical housing and adapted to manipulate a plug in the end of the tube, and a telescopic hydraulic ram adapted to move the piston toward the plug. In addition the wrench contains a magnet which prevents inadvertent uncoupling of the wrench and the plug. 7 claims, 10 drawing figures

  19. Continuous pile discharging machine

    Science.gov (United States)

    Smith, Phillips P.

    1976-05-11

    A device for discharging cartridges from tubes under fluid pressure includes a cylindrical housing adapted to be seated in a leak-tight manner on the end of one of the tubes, a chute depending from the cylindrical housing near the end seated on the end of the tube, a rotatable piston having a wrench on the forward end thereof disposed in the cylindrical housing and adapted to manipulate a plug in the end of the tube, and a telescopic hydraulic ram adapted to move the piston toward the plug. In addition the wrench contains a magnet which prevents inadvertent uncoupling of the wrench and the plug.

  20. Modelling the combined impact of radionuclide discharges reaching rivers

    International Nuclear Information System (INIS)

    Hilton, J.; Small, S.; Hornby, D.; Scarlett, P.; Harvey, M.; Simmonds, J.; Bexon, A.; Jones, A.

    2003-01-01

    The Agency currently authorises direct and indirect (via sewerage systems) discharges of liquid radioactive wastes to rivers from nuclear sites and other registered users of radioactivity. Discharges are normally authorised on a site-by-site basis, taking into account the radiological assessment. Radiological assessments are normally made using dilution models to estimate radionuclide activities in the effluents themselves and in the receiving rivers. These data are then combined with information on habits and dose factor information to give a dose assessment for individuals exposed to the discharge. For each site the highest radiological impact is expected immediately downstream of the disposal point where concentrations of radionuclides and resulting doses are highest. The concentration and doses are expected to decline with increasing distance downstream of the disposal point. However, if discharges are made into the river from other establishments higher up the catchment, the total dose may be higher. Recent Environment Agency research projects provided evidence of the potential radiological significance of multiple discharges to a single river. In the light of these studies, the Agency require a robust modelling tool to assist in the assessment of the effects of combined discharges to river systems. The aim of this R and D project was to develop and test modelling tools that could be used to make assessments of the impact of multiple radiological discharge into river systems and to trial them on the upper Thames river system

  1. Preset Electrodes for Electrical-Discharge Machining

    Science.gov (United States)

    Coker, Bill E.

    1987-01-01

    New electrode holder for electrical-discharge machining (EDM) provides for repeatable loading and setting of many electrodes. New holder is rotating-index tool carrying six, eight, or more electrodes. Before use, all electrodes set with aid of ring surrounding tool, and locked in position with screws. When electrode replaced, EDM operator pulls spring-loaded pin on tool so it rotates about center pin. Fresh electrode then rotated into position against workpiece.

  2. Aquatic indicator organisms as a tool to monitor discharges from nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Outola, Iisa; Vartti, Vesa-Pekka; Klemola, Seppo [STUK - Radiation and Nuclear Safety Authority, P.O. Box 14, 00881 Helsinki (Finland)

    2014-07-01

    There are four operating nuclear power plant units in Finland at two separate locations. The units started operation during 1977-1980. The surveillance of radioactive substances in the vicinities of the nuclear power plant is carried out under the permanent monitoring programs. Some 1000 samples are taken annually from the surroundings of the power plants to confirm that the discharges from the power plants are within permissible release limits and to monitor the dispersion of discharges in the environment. Aquatic indicator organisms (macro-algae, periphyton, mussels, crustacean, submerged aquatic plants) are included in the monitoring program. The indicator organisms are valuable monitoring objects both in normal and emergency situations because they accumulate effectively and often very rapidly radioactive substances from the medium. Six different species (Periphyton, Fucus vesiculosus, Myriophyllum spicatum, Potamogeton pectinatus, Saduria entomon, Macoma Baltica/Mytilus edulis) are collected regularly. Number of sampling location for each species varies from 1 to 7. Some species are collected continuously, some 1-2 times in a year. In this study we have evaluated the monitoring results for the aquatic indicator organisms for the period of 2005-2010 concerning concentration of discharge nuclides. Our aim was to answer the following questions using the monitoring data from aquatic organisms: 1) Which radionuclides are released to the marine environment and how often do we detect them? 2) How far from the nuclear power plants discharge radionuclides are detected? 3) How concentration of discharge radionuclides has changed with time in aquatic organisms? The number of discharge nuclides detected in the aquatic indicator samples was 11. Most of them were only detected in few samples, but {sup 58}Co, {sup 60}Co, {sup 54}Mn and {sup 110m}Ag were detected more frequently. Most of the observations above detection limits were made within the 5 km distance from the

  3. Hydrogen sulfide dissociation in a barrier discharge plasma

    International Nuclear Information System (INIS)

    Teimurova, F.A.; Rasulov, A.M.; Klimov, N.T.

    1992-01-01

    The authors studied the decomposition of hydrogen sulfide in a barrier discharge. The choice of a barrier discharge was not made by chance. It possesses the following properties resulting in its having advantage over other types of discharges. (1) Use of a barrier discharge permits one to obtain superequilibrium atom concentrations for a given temperature owing to the nonisothermic plasma of a barrier discharge, i.e., along with the existence of a relatively low molecular gas temperature there is a very high electron gas temperature; this temperature difference is typical of an isobaric potential in the low temperature plasma of a barrier discharge, which lasts till cessation of operation; (2) a large number of microscopic discharges fill the entire discharge zone and as a consequence, the charged particles attain very high energies, assuring their intense destructive action; (3) the mean gas temperature in the barrier discharge hardly exceeds the temperature of the surroundings so there is no significant heat loss. 6 refs., 1 fig

  4. 33 CFR 157.37 - Discharge of oily mixtures from oil cargoes.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Discharge of oily mixtures from... CARRYING OIL IN BULK Vessel Operation § 157.37 Discharge of oily mixtures from oil cargoes. (a) A tank vessel may not discharge an oily mixture into the sea from a cargo tank, slop tank, or cargo pump room...

  5. Normal Pressure Hydrocephalus (NPH)

    Science.gov (United States)

    ... local chapter Join our online community Normal Pressure Hydrocephalus (NPH) Normal pressure hydrocephalus is a brain disorder ... Symptoms Diagnosis Causes & risks Treatments About Normal Pressure Hydrocephalus Normal pressure hydrocephalus occurs when excess cerebrospinal fluid ...

  6. Analysis of Multipactor Discharge

    International Nuclear Information System (INIS)

    Lau, Y. Y.

    2005-01-01

    Several comprehensive studies of radio frequency (rf) breakdown and rf heating are reported. They are of general interest to magnetic confinement fusion, rf linac, and high power microwave source development. The major results include: (1) a ground-breaking theory of multipactor discharge on dielectric, including a successful proof-of-principle experiment that verified the newly developed scaling laws, (2) an in depth investigation of the failure mechanisms of diamond windows and ceramic windows, and of the roles of graphitization, thin films of coating and contaminants, and (3) a most comprehensive theory, to date, on the heating of particulates by an electromagnetic pulse, and on the roles of rf magnetic field heating and of rf electric field heating, including the construction of new scaling laws that govern them. The above form a valuable knowledge base for the general problem of heating phenomenology

  7. Heart bypass surgery - minimally invasive - discharge

    Science.gov (United States)

    ... invasive direct coronary artery bypass - discharge; MIDCAB - discharge; Robot assisted coronary artery bypass - discharge; RACAB - discharge; Keyhole ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  8. Dielectric barrier discharges: progress on plasma sources and on the understanding of regimes and single filaments

    Science.gov (United States)

    Brandenburg, Ronny

    2017-05-01

    Dielectric barrier discharges (DBDs) are plasmas generated in configurations with an insulating (dielectric) material between the electrodes which is responsible for a self-pulsing operation. DBDs are a typical example of nonthermal atmospheric or normal pressure gas discharges. Initially used for the generation of ozone, they have opened up many other fields of application. Therefore DBDs are a relevant tool in current plasma technology as well as an object for fundamental studies. Another motivation for further research is the fact that so-called partial discharges in insulated high voltage systems are special types of DBDs. The breakdown processes, the formation of structures, and the role of surface processes are currently under investigation. This review is intended to give an update to the already existing literature on DBDs considering the research and development within the last two decades. The main principles and different modes of discharge generation are summarized. A collection of known as well as special electrode configurations and reactor designs will be presented. This shall demonstrate the different and broad possibilities, but also the similarities and common aspects of devices for different fields of applications explored within the last years. The main part is devoted to the progress on the investigation of different aspects of breakdown and plasma formation with the focus on single filaments or microdischarges. This includes a summary of the current knowledge on the electrical characterization of filamentary DBDs. In particular, the recent new insights on the elementary volume and surface memory mechanisms in these discharges will be discussed. An outlook for the forthcoming challenges on research and development will be given.

  9. ESCLOUD: A computer program to calculate the air concentration, deposition rate and external dose rate from a continuous discharge of radioactive material to atmosphere

    International Nuclear Information System (INIS)

    Jones, J.A.

    1980-03-01

    Radioactive material may be discharged to atmosphere in small quantities during the normal operation of a nuclear installation as part of a considered waste management practice. Estimates of the individual and collective dose equivalent rates resulting from such a discharge are required in a number of contexts: for example, in assessing compliance with dose limits, in estimating the radiological impact of the discharge and as an input into optimisation studies. The suite of programs which has been developed to undertake such calculations is made up of a number of independent modules one of which, ESCLOUD, is described in this report. The ESCLOUD program evaluates, as a function of distance and direction from the release point, the air concentration, deposition rate and external β and γ doses from airborne and deposited activity. The air concentration and deposition rate can be used as input to other modules for calculating inhalation and ingestion doses. (author)

  10. State Waste Discharge Permit application: 200-W Powerhouse Ash Pit

    Energy Technology Data Exchange (ETDEWEB)

    Atencio, B.P.

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations; the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect groundwater would be subject to permitting under the structure of Chapter 173-216 (or 173-218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. This document constitutes the State Waste Discharge Permit application for the 200-W Powerhouse Ash Pit. The 200-W Powerhouse Ash Waste Water discharges to the 200-W Powerhouse Ash Pit via dedicated pipelines. The 200-W Powerhouse Ash Waste Water is the only discharge to the 200-W Powerhouse Ash Pit. The 200-W Powerhouse is a steam generation facility consisting of a coal-handling and preparation section and boilers.

  11. State Waste Discharge Permit application: 200-E Powerhouse Ash Pit

    Energy Technology Data Exchange (ETDEWEB)

    Atencio, B.P.

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations, the US Department and Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect groundwater would be subject to permitting under the structure of Chapter 173-216 (or 173-218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. This document constitutes the State Waste Discharge Permit application for the 200-E Powerhouse Ash Pit. The 200-E Powerhouse Ash Waste Water discharges to the 200-E Powerhouse Ash Pit via dedicated pipelines. The 200-E Ash Waste Water is the only discharge to the 200-E Powerhouse Ash Pit. The 200-E Powerhouse is a steam generation facility consisting of a coal-handling and preparation section and boilers.

  12. State waste discharge permit application: Hydrotest, maintenance and construction discharges. Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    On December 23, 1991, the US DOE< Richland Operation Office (RL) and the Washington State Department of Ecology (Ecology) agreed to adhere to the provisions of the Department of Ecology Consent Order No. DE91NM-177 (216 Consent Order) (Ecology and US DOE 1991). The 216 Consent Order list regulatory milestones for liquid effluent streams at the Hanford Site and requires compliance with the permitting requirements of Washington Administrative Code. Hanford Site liquid effluent streams discharging to the soil column have been categorized on the 216 Consent Order as follows: Phase I Streams; Phase II Streams; Miscellaneous Streams. Phase I and Phase II Streams were initially addressed in two report. Miscellaneous Streams are subject to the requirements of several milestones identified in the 216 Consent Order. This document constitutes the Categorical State Waste Discharge Permit application for hydrotest,maintenance and construction discharges throughout the Hanford Site. This categorical permit application form was prepared and approved by Ecology.

  13. State waste discharge permit application: Hydrotest, maintenance and construction discharges. Revision 0

    International Nuclear Information System (INIS)

    1995-11-01

    On December 23, 1991, the US DOE< Richland Operation Office (RL) and the Washington State Department of Ecology (Ecology) agreed to adhere to the provisions of the Department of Ecology Consent Order No. DE91NM-177 (216 Consent Order) (Ecology and US DOE 1991). The 216 Consent Order list regulatory milestones for liquid effluent streams at the Hanford Site and requires compliance with the permitting requirements of Washington Administrative Code. Hanford Site liquid effluent streams discharging to the soil column have been categorized on the 216 Consent Order as follows: Phase I Streams; Phase II Streams; Miscellaneous Streams. Phase I and Phase II Streams were initially addressed in two report. Miscellaneous Streams are subject to the requirements of several milestones identified in the 216 Consent Order. This document constitutes the Categorical State Waste Discharge Permit application for hydrotest,maintenance and construction discharges throughout the Hanford Site. This categorical permit application form was prepared and approved by Ecology

  14. Early discharge after external anal sphincter repair

    DEFF Research Database (Denmark)

    Rosenberg, J; Kehlet, H

    1999-01-01

    and complications within 30 days after the operation. Surgery was performed during the period of March 1993 to May 1997. The accelerated-stay program included preoperative information, no premedication, a surgical procedure without colostomy, single-dose prophylactic antibiotics, paracetamol for analgesia, free...... oral fluid and food immediately after the operation supplemented by laxatives, and enforced mobilization. Follow-up by questionnaire was performed at a median of 14 (range, 4-52) months after the operation. RESULTS: Median hospital stay was one day. Fifteen patients were discharged the day after...... surgery and 5 patients stayed for 48 hours after the operation. There was no 30-day morbidity, and no patient received a colostomy in conjunction with the sphincter repair. Fourteen of 19 patients available for follow-up reported a significantly improved functional result compared with preoperative state...

  15. Spectroscopic characterisation of an atmospheric pressure glow discharge

    International Nuclear Information System (INIS)

    Gomez, S.; Steen, P.G.; Morrow, T.; Graham, W.G.

    2001-01-01

    Recently there has been considerable interest in atmospheric discharges operating in a glow discharge mode i.e. with a spatial and sheath structure similar to that of low pressure glow discharges. Here spectroscopy has been used to characterise an atmospheric pressure glow discharge (APGD), operating with either dry air, argon or helium gas flowing through the inter-electrode space and with the inter-electrode gap either free or with woven polypropylene or polyester samples present. Emission spectroscopy is used to determine the rotational and vibrational temperature of the nitrogen gas, while electron temperatures are determined from the relative intensities of Ar emission lines. Ozone production is monitored by a simple absorption technique to evaluate its potential in process control

  16. Effects of corona discharge treatment on some properties of wool ...

    African Journals Online (AJOL)

    Yomi

    2011-12-21

    Dec 21, 2011 ... Worsted corona discharge was under operation, while the operation conditions were optimized. Processed woolen surface properties such as water absorption and staining properties were investigated. In addition, the bending length, wrinkle recovery and tensile strength retention (%) of treated samples ...

  17. Impacts of thermal and chemical discharges to surface water

    International Nuclear Information System (INIS)

    Stober, Q.J.

    1974-01-01

    Various aspects of thermal and chemical discharges to surface water are outlined. The major impacts of nuclear power plants on aquatic resources are disruption during construction, intake of cooling water, discharge problems, and interactions with other water users. The following topics are included under the heading, assessment of aquatic ecology: identification of flora and fauna; abundance of aquatic organisms; species-environment relationships; and identification of pre-existing environmental stress. The following topics are included under the heading, environmental effects of plant operation: entrapment of fish by cooling water; passage of plankton through cooling system; discharge area and thermal plume; chemical effluents; and plant construction. (U.S.)

  18. Charge Management in LISA Pathfinder: The Continuous Discharging Experiment

    Science.gov (United States)

    Ewing, Becca Elizabeth

    2018-01-01

    Test mass charging is a significant source of excess force and force noise in LISA Pathfinder (LPF). The planned design scheme for mitigation of charge induced force noise in LISA is a continuous discharge by UV light illumination. We report on analysis of a charge management experiment on-board LPF conducted during December 2016. We discuss the measurement of test mass charging noise with and without continuous UV illumination, in addition to the dynamic response in the continuous discharge scheme. Results of the continuous discharge system will be discussed for their application to operating LISA with lower test mass charge.

  19. Ozone production in a dielectric barrier discharge with ultrasonic irradiation

    DEFF Research Database (Denmark)

    Drews, Joanna Maria; Kusano, Yukihiro; Leipold, Frank

    2011-01-01

    Ozone production has been investigated using an atmospheric pressure dielectric barrier discharge in pure O2 at room temperature with and without ultrasonic irradiation. It was driven at a frequency of either 15 kHz or 40 kHz. The ozone production was highly dependent on the O2 flow rate...... and the discharge power. Furthermore, powerful ultrasonic irradiation at a fundamental frequency of 30 kHz with the sound pressure level of 150 dB into the discharge can improve the ozone production efficiency, particularly when operated at the frequency of 15 kHz at the flow rate of 15 L/min....

  20. Sandia's severe human body Electrostatic Discharge Tester (SSET)

    International Nuclear Information System (INIS)

    Barnum, J.R.

    1991-01-01

    This paper reports that the Electromagnetic Testing Division at Sandia National Laboratories (SNL) has developed a simulator to replicate a severe human body electrostatic discharge event. This simulator is referred to as Sandia's Severe Human Body Electrostatic Discharge Tester (SSET). The SSET is configured as a coaxial transmission line, which allows control of parasitic inductance and capacitance to achieve the desired waveform signature, and operates reliably at voltages up to 35 kV. It is constructed from off-the-shelf or easily fabricated components and costs approximately $750 for materials, not including the power supply. The output is very repeatable and provides good simulation fidelity of a severe human body discharge

  1. Spent nuclear fuel discharges from U.S. reactors 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    Spent Nuclear Fuel Discharges from US Reactors 1994 provides current statistical data on fuel assemblies irradiated at commercial nuclear reactors operating in the US. This year`s report provides data on the current inventories and storage capacities at these reactors. Detailed statistics on the data are presented in four chapters that highlight 1994 spent fuel discharges, storage capacities and inventories, canister and nonfuel component data, and assembly characteristics. Five appendices, a glossary, and bibliography are also included. 10 figs., 34 tabs.

  2. All solid state pulsed power system for water discharge

    OpenAIRE

    Sakugawa, Takashi; Yamaguchi, Takahiro; Yamamoto, Kunihiro; Kiyan, Tsuyoshi; Namihira, Takao; Katsuki, Sunao; Akiyama, Hidenori; サクガワ, タカシ; ヤマグチ, タカヒロ; ヤマモト, クニヒロ; キヤン, ツヨシ; ナミヒラ, タカオ; カツキ, スナオ; アキヤマ, ヒデノリ; 佐久川, 貴志

    2005-01-01

    Pulsed power has been used to produce non-thermal plasmas in gases that generate a high electric field at the tip of streamer discharges, where high energy electrons, free radicals, and ozone are produced. Recently, all solid state pulsed power generators, which are operated with high repetition rate, long lifetime and high reliability, have been developed for industrial applications, such as high repetition rate pulsed gas lasers, high energy density plasma (EUV sources) and water discharges...

  3. Real time analysis of tokamak discharge parameters

    International Nuclear Information System (INIS)

    Ferron, J.R.; Strait, E.J.

    1992-03-01

    The techniques used in implementing two applications of real time analysis of data from the DIII-D tokamak are described. These tasks, which are demanding in both the speed of data acquisition and the speed of computation, execute on hardware capable of acquiring 40 million data samples per second and executing 80 million floating point operations per second. In the first case, a feedback control algorithm executing at a 10 kHz cycle frequency is used to specify the current in the poloidal field coils in order to control the discharge shape. In the second, fast Fourier transforms of Mirnov probe data are used to find the amplitude and frequency of each of eight toroidal mode numbers as a function of time during the discharge. Data sampled continuously at 500 kHz are used to produce results at 2 msec intervals

  4. Real time analysis of tokamak discharge parameters

    International Nuclear Information System (INIS)

    Ferron, J.R.; Strait, E.J.

    1992-01-01

    The techniques used in implementing two applications of real time digital analysis of data from the DIII-D tokamak are described. These tasks, which are demanding in both the speed of data acquisition and the speed of computation, execute on hardware capable of acquiring 40 million data samples per second and executing 80 million floating point operations per second. In the first case, a feedback control algorithm executing at a 10 kHz cycle frequency is used to specify the current in the poloidal field coils in order to control the discharge shape. In the second, fast Fourier transforms of Mirnov probe data are used to find the amplitude and frequency of each of eight toroidal mode numbers as a function of time during the discharge. Data sampled continuously at 500 kHz are used to produce results at 2 ms intervals

  5. Predictors and outcomes of postpartum mothers' perceptions of readiness for discharge after birth.

    Science.gov (United States)

    Weiss, Marianne E; Lokken, Lisa

    2009-01-01

    To identify predictors and outcomes of postpartum mothers' perceptions of their readiness for hospital discharge. A correlational design with path analyses was used to explore predictive relationships among transition theory-related variables. Midwestern tertiary perinatal center. One hundred and forty-one mixed-parity postpartum mothers who had experienced vaginal birth or Cesarean delivery of normal healthy infants. Before hospital discharge, patients completed questionnaires about sociodemographic characteristics, hospitalization factors, quality of discharge teaching, and readiness for discharge. Three weeks postdischarge, mothers were contacted by telephone to collect coping difficulty and health care utilization data. Readiness for Hospital Discharge Scale, Post-Discharge Coping Difficulty Scale, Utilization of postdischarge services. Quality of discharge teaching, specifically the relative difference in the amount of informational content needed and received and the skills of nurses in delivering discharge teaching, explained 38% of the variance in postpartum mothers' perceptions of discharge readiness. Readiness for discharge scores explained 22% of the variance in postdischarge coping difficulty scores. Nurses' skills in delivery of discharge teaching, coping difficulty, patient characteristics, and birth hospitalization factors were predictive of utilization of family support and postdischarge health care services. A trajectory of influence was evident in the sequential relationships of quality of discharge teaching, readiness for discharge, postdischarge coping, and utilization of family support and health care services. Transitions theory provided a useful framework for conceptualizing and investigating the transition home after childbirth.

  6. Positive ion species in high-density discharges containing chlorine and boron endash trichloride

    International Nuclear Information System (INIS)

    Woodworth, J.R.; Nichols, C.A.; Hamilton, T.W.

    1998-01-01

    We have used a quadrupole mass spectrometer to measure the positive ion species striking the wafer in a high-density plasma processing discharge containing chlorine and boron endash trichloride. Since the relative transmission of our mass spectrometer versus ion mass is known, we are able to report the relative concentrations of the ion species striking the wafer. Our measurements were made in an inductively coupled Gaseous Electronics Conference Reference Cell operating at pressures between 15 and 50 mTorr and at electron densities up to 10 11 /cm 3 . The ion spectrum in these discharges is normally dominated by Cl + , Cl 2 + , BCl 2 + , and etch products. However, reactor wall or wafer surface conditions can strongly affect the ion species in the discharge. When a stainless steel open-quotes waferclose quotes was replaced with a bare Si wafer, the dominant chlorine ion changed from Cl + to Cl 2 + . A bare aluminum wafer strongly quenched both Cl + and Cl 2 + signals. copyright 1998 American Vacuum Society

  7. The ASDEX Upgrade discharge schedule

    International Nuclear Information System (INIS)

    Neu, G.; Engelhardt, K.; Raupp, G.; Treutterer, W.; Zasche, D.; Zehetbauer, T.

    2007-01-01

    ASDEX Upgrade's recently commissioned discharge control system (DCS) marks the transition from a traditional programmed system to a highly flexible 'data driven' one. The allocation of application processes (APs) to controllers, the interconnection of APs through uniquely named signals, and AP control parameter values are all defined as data, and can easily be adapted to the requirements of a particular discharge. The data is laid down in a set of XML documents which APs request via HTTP from a configuration server before a discharge. The use of XML allows for easy parsing, and structural validation through (XSD) schemas. The central input to the configuration process is the discharge schedule (DS), which embodies the dynamic behaviour of a planned discharge as reference trajectories grouped in segments, concatenated through transition conditions. Editing, generation and validation tools, and version control through CVS allow for efficient management of DSs

  8. Technological plasma source equipped with combined system of vacuum-arc discharge initiation

    International Nuclear Information System (INIS)

    Sysoev, Yu.O.

    2013-01-01

    The construction and the operation principle of erosion plasma source with a three-stage system of vacuum-arc discharge excitation is described. As first two step was used the modified contactless start system with plasma injector, which was widely used in standard plasma sources of the ''Bulat'' systems. The operation principle of the third stage was based on the transition of glow discharge to arc discharge. Coordinated operation of three stages during various stages of coating deposition provided significant increasing of service life and reliability of the system of vacuum-arc discharge initiation and extended the functionality of the plasma source

  9. Testing for normality

    CERN Document Server

    Thode, Henry C

    2002-01-01

    Describes the selection, design, theory, and application of tests for normality. Covers robust estimation, test power, and univariate and multivariate normality. Contains tests ofr multivariate normality and coordinate-dependent and invariant approaches.

  10. Study and optimization of magnetized ICRF discharges for tokamak wall conditioning and assessment of the applicability to ITER

    International Nuclear Information System (INIS)

    Wauters, T.

    2011-11-01

    This work is devoted to the study and optimization of the Ion Cyclotron Wall Conditioning (ICWC) technique. ICWC, operated in presence of the toroidal magnetic field, makes use of four main tokamak systems: the ICRF antennas to initiate and sustain the conditioning discharge, the gas injection valves to provide the discharge gas, the machine pumps to remove the wall desorbed particles, and the poloidal magnetic field system to optimize the discharge homogeneity. Additionally neutral gas and plasma diagnostics are required to monitor the discharge and the conditioning efficiency. In chapter 2 a general overview on ICWC is given. Chapter 3 treats the ICRF discharge homogeneity and the confinement properties of the employed magnetic field. In the first part we will discuss experimental facts on plasma homogeneity, and how experimental optimization led to its improvement. In the second part of the chapter the confinement properties of a partially ionized plasma in a toroidal magnetic field configuration with additional small vertical component are discussed. Chapter 4 gives an overview of experimental results on the efficiency of ICWC, obtained on TORE SUPRA, TEXTOR, JET and ASDEX Upgrade. In chapter 5 a 0D kinetic description of hydrogen-helium RF plasmas is outlined. The model, describing the evolution of ICRF plasmas from discharge initiation to the (quasi) steady state plasma stage, is developed to obtain insight on ICRF plasma parameters, particle fluxes to the walls and the main collisional processes. Chapter 6 presents a minimum structure for a 0D reservoir model of the wall to investigate in deeper detail the ICWC plasma wall interaction during isotopic exchange experiments. The hypothesis used to build up the wall model is that the same model structure should be able to describe the wall behavior during normal plasmas and conditioning procedures. Chapter 7 extrapolates the results to the envisaged application of ICWC on ITER

  11. 33 CFR 159.315 - Sewage and graywater discharge record book.

    Science.gov (United States)

    2010-07-01

    ... record book. 159.315 Section 159.315 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND... by Cruise Vessel Operations § 159.315 Sewage and graywater discharge record book. (a) While operating... and Graywater Discharge Record Book with the vessel's name and official number listed on the front...

  12. Discharge Planning in Chronic Conditions

    Science.gov (United States)

    McMartin, K

    2013-01-01

    Background Chronically ill people experience frequent changes in health status accompanied by multiple transitions between care settings and care providers. Discharge planning provides support services, follow-up activities, and other interventions that span pre-hospital discharge to post-hospital settings. Objective To determine if discharge planning is effective at reducing health resource utilization and improving patient outcomes compared with standard care alone. Data Sources A standard systematic literature search was conducted for studies published from January 1, 2004, until December 13, 2011. Review Methods Reports, randomized controlled trials, systematic reviews, and meta-analyses with 1 month or more of follow-up and limited to specified chronic conditions were examined. Outcomes included mortality/survival, readmissions and emergency department (ED) visits, hospital length of stay (LOS), health-related quality of life (HRQOL), and patient satisfaction. Results One meta-analysis compared individualized discharge planning to usual care and found a significant reduction in readmissions favouring individualized discharge planning. A second meta-analysis compared comprehensive discharge planning with postdischarge support to usual care. There was a significant reduction in readmissions favouring discharge planning with postdischarge support. However, there was significant statistical heterogeneity. For both meta-analyses there was a nonsignificant reduction in mortality between the study arms. Limitations There was difficulty in distinguishing the relative contribution of each element within the terms “discharge planning” and “postdischarge support.” For most studies, “usual care” was not explicitly described. Conclusions Compared with usual care, there was moderate quality evidence that individualized discharge planning is more effective at reducing readmissions or hospital LOS but not mortality, and very low quality evidence that it is more

  13. Recurrent vaginal discharge in children.

    Science.gov (United States)

    McGreal, Sharon; Wood, Paul

    2013-08-01

    Childhood vaginal discharge remains a frequent reason for referral from primary to secondary care. The Pediatric and Adolescent Gynecology (PAG) service at Kettering General Hospital was established in 1993 and provides a specialized service that meets the needs of children with gynaecological conditions. To investigate recurrent vaginal discharge noting symptomatology, defining pathogens, common and rarer causes, exploring management regimes, and any changes in practice over time. Retrospective review spanning 15 years identifying prepubertal children attending the outpatient PAG clinic with recurrent vaginal discharge. We reviewed the medical notes individually. 110 patients were identified; 85% were referred from primary care. The age distribution was bimodal at four and eight years. Thirty-five percent of our patients were discharged after the initial consultation. The commonest cause of discharge was vulvovaginitis (82%). Other important causes included suspected sexual abuse (5%), foreign body (3%), labial adhesions (3%), vaginal agenesis (2%). 35% of patients were admitted for vaginoscopy. Vaginal discharge is the most common gynecological symptom in prepubertal girls and can cause repeated clinical episodes. Vulvovaginitis is the most common cause and often responds to simple hygiene measures. Awareness of the less common causes of vaginal discharge is essential. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  14. Optimization of the monitoring of liquid discharges from the Temelin nuclear power plant

    International Nuclear Information System (INIS)

    Ivanovova, Diana; Hanslik, Eduard

    2009-01-01

    The main goals of the project included (i) examination of the kinetics of wastewater transport from the Temelin NPP to the watercourse (Vltava river) and the kinetics of the contaminants in the watercourse, considering normal monitoring conditions and radiological emergency situations, and (ii) prediction of the transport of contaminants, in particular profiles downstream of the points of wastewater discharge from the plant. Wastewater flow velocity within the NPP and in the Vltava river segment between the Korensko Dam (wastewater release) and Hladna profiles was studied. Tritium that is normally released with wastewater served as the tracer. The results indicated how the tritium flow time patterns depend on the flow rate of the watercourse and on the pathway through which the wastewater is discharged (via the hydroelectric installation at the Korensko Dam, to the weir sluices, and directly to the watercourse). The tritium balance in the wastewater and in the Vltava river was calculated and compared to the released activity data provided by the Temelin plant operator (CEZ Group utility). (orig.)

  15. The Normal Distribution From Binomial to Normal

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 6. The Normal Distribution From Binomial to Normal. S Ramasubramanian. Series Article Volume 2 Issue 6 June 1997 pp 15-24. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/002/06/0015-0024 ...

  16. State Waste Discharge Permit application for industrial discharge to land: 200 East Area W-252 streams

    Energy Technology Data Exchange (ETDEWEB)

    1993-12-01

    This document constitutes the WAC 173-216 State Waste Discharge Permit application for six W-252 liquid effluent streams at the Hanford Site. Appendices B through H correspond to Section B through H in the permit application form. Within each appendix, sections correspond directly to the respective questions on the application form. The appendices include: Product or service information; Plant operational characteristics; Water consumption and waterloss; Wastewater information; Stormwater; Other information; and Site assessment.

  17. State Waste Discharge Permit application for industrial discharge to land: 200 East Area W-252 streams

    International Nuclear Information System (INIS)

    1993-12-01

    This document constitutes the WAC 173-216 State Waste Discharge Permit application for six W-252 liquid effluent streams at the Hanford Site. Appendices B through H correspond to Section B through H in the permit application form. Within each appendix, sections correspond directly to the respective questions on the application form. The appendices include: Product or service information; Plant operational characteristics; Water consumption and waterloss; Wastewater information; Stormwater; Other information; and Site assessment

  18. Legal aspects of thermal discharges

    International Nuclear Information System (INIS)

    Martin, A.J.

    1974-01-01

    An overview of those legal areas which directly affect technical and planning decisions is presented in the form of 2 legal approaches which constrain the indiscriminate release of thermal discharges to receiving waters. One takes the form of private remedies which have traditionally been available to aggrieved parties who are in some way damaged by the harmful discharge. The 2nd approach utilizes the various statutory constraints leading to direct governmental action. It appears that statutory law is playing the prominent role in restricting the temperature to which receiving waters may be raised as a result of such discharges by using effluent limitations and water quality standards. (Water Resour. Abstr.)

  19. An introduction to gas discharges

    CERN Document Server

    Howatson, A M

    2013-01-01

    An Introduction to Gas Discharges: Second Edition aims to provide a compact introduction to the subject of gas discharges, which continues to make both scientific and industrial progress. In this second edition, the author has made minor corrections, rewritten and expanded some sections, used SI units and modernized notions, in hopes of making the book more up to date. Included in the book is a short history of the subject, an introduction that enumerates the types of gas discharges, the fundamental processes, and then moves on to the more specific areas such as the breakdown, the self-sustai

  20. Harwell Laboratory: radioactive discharges and environmental monitoring

    International Nuclear Information System (INIS)

    1991-06-01

    The United Kingdom Atomic Energy Authority's Harwell Laboratory is situated some 5 miles west of Didcot in Oxfordshire. The AEA Businesses located at the Laboratory carry out a wide range of nuclear and non-nuclear investigations for customers in the UK and overseas. This report provides information on disposal of radioactive waste from Harwell and on associated environmental monitoring for the calendar year 1990. In most instances information has also been provided on measurements made in previous years to show the 1990 results in their historical perspective. The National Radiological Protection Board, (NRPB) currently recommends a primary dose limit for individual members of the public of 1 mSv per year from sources other than natural background radiation, and that operations of a single site such as Harwell should give rise to a dose of no more than 0.5 mSv per year. No member of the public is judged to have exceeded this dose as a consequence of discharges made in 1990. Throughout this report, discharge measurements have been assessed against derived limits corresponding to a dose of 0.5 mSv, consistent with NRPB advice. At the end of March 1990, the Harwell materials testing reactors, DIDO and PLUTO, were shut down for the final time after over 34 years' operation. Later in the year the GLEEP reactor was closed down after 43 years of continuous operation, the longest serving reactor in the world. (author)

  1. Optimization and scaling of a pulser-sustainer discharge excited oxygen-iodine laser

    Science.gov (United States)

    Bruzzese, J.; Nishihara, M.; Hicks, A.; Lempert, W. R.; Rich, J. W.; Adamovich, I. V.

    2008-05-01

    The paper discusses optimization of gain and output power and scaling of a pulser-sustainer discharge excited oxygen-iodine laser. For this, NO addition to the laser mixture and iodine vapor dissociation in an auxiliary high-voltage, nanosecond pulse duration, repetitively pulsed discharge ("side" discharge) are used. Iodine dissociation fraction generated in the side discharge and measured in the M=3 laser cavity is up to 50%. The experiments showed that additional iodine dissociation generated in the side discharge only moderately increased laser gain, by 10-15%. Parametric gain optimization by varying main discharge pressure, O2 and NO fractions in the flow, I2 flow rate, pulsed discharge frequency, and sustainer discharge power, with the side discharge in operation produced gain up to 0.08 %/cm. Two parameters that critically affect gain are the energy loading per molecule in the discharge and the NO flow rate controlling the O atom concentration in the flow. Operation at the main discharge pressure of 60 torr resulted in significantly higher gain than at 100 torr, 0.080 %/cm vs. 0.043 %/cm, due to high discharge energy loading per molecule at the lower pressure. Laser output power measured at the gain optimized conditions is 1.4 W. Experiments with a scaled-up laser with a large volume pulser-sustainer discharge (10 cm x 10 cm x 2 cm vs. 5 cm x 5 cm x 2 cm) and longer gain path (10 cm vs. 5 cm) demonstrated stable discharge operation at discharge powers up to at least 2.9 kW. Singlet delta yield and gain measurements in the scaled-up laser are underway.

  2. Clinical Impact of Epileptiform Discharge in Children With Attention-Deficit/Hyperactivity Disorder (ADHD).

    Science.gov (United States)

    Lee, Eun Hye; Choi, Yong Sung; Yoon, Hoi Soo; Bahn, Geon Ho

    2016-04-01

    The aim of this study was to investigate the prevalence and clinical significance of epileptiform discharges in patients with attention-deficit/hyperactivity disorder (ADHD). The authors retrospectively reviewed 180 children who were diagnosed with ADHD and had an electroencephalography (EEG) recording. Epileptiform discharges were found in 29 (16.1%) of 180 patients with ADHD. Of these, 15 (8.3%) had generalized epileptiform discharges and 14 (7.7%) had focal epileptiform discharges. The focal epileptiform discharges were most prevalent from the frontal (5/14) and rolandic area (5/14). Among the 29 patients with epileptiform discharges and ADHD, 5 patients had previous history of epilepsy and 4 patients developed epilepsy later, whereas none of the normal EEG group developed epilepsy. The authors suggest that interictal epileptiform discharges appear to be associated with seizure occurrence in children with ADHD and might reflect maturational pathophysiology overlapping with epilepsy. © The Author(s) 2015.

  3. Capacitor discharge process for welding braided cable

    Science.gov (United States)

    Wilson, Rick D.

    1995-01-01

    A capacitor discharge process for welding a braided cable formed from a plurality of individual cable strands to a solid metallic electrically conductive member comprises the steps of: (a) preparing the electrically conductive member for welding by bevelling one of its end portions while leaving an ignition projection extending outwardly from the apex of the bevel; (b) clamping the electrically conductive member in a cathode fixture; (c) connecting the electrically conductive member clamped in the cathode fixture to a capacitor bank capable of being charged to a preselected voltage value; (d) preparing the braided cable for welding by wrapping one of its end portions with a metallic sheet to form a retaining ring operable to maintain the individual strands of the braided cable in fixed position within the retaining ring; (e) clamping the braided cable and the retaining ring as a unit in an anode fixture so that the wrapped end portion of the braided cable faces the ignition projection of the electrically conductive member; and (f) moving the cathode fixture towards the anode fixture until the ignition projection of the electrically conductive member contacts the end portion of the braided cable thereby allowing the capacitor bank to discharge through the electrically conductive member and through the braided cable and causing the electrically conductive member to be welded to the braided cable via capacitor discharge action.

  4. Harwell Laboratory radioactive discharges and environmental monitoring

    International Nuclear Information System (INIS)

    1992-06-01

    This report provides information on disposal of radioactive waste from Harwell and on associated environmental monitoring for the calendar year 1991. In most instances information has also been provided on measurements made in previous years to show the 1991 results in their historical perspective. The National Radiological Protection Board, (NRPB) currently recommends a primary dose limit for individual members of the public of 1 mSv per year from sources other than natural background radiation. Operations of a single site such as Harwell should give rise to a dose of no more than 0.5 mSv per year. No member of the public is judged to have exceeded this dose as a consequence of discharges made in 1991. Throughout this report, discharge measurements have been assessed against derived limits corresponding to a dose of 0.5 mSv, consistent with NRPB advice. During the year, work was completed on the revision of both the atmospheric and liquid discharge authorisations, bringing to a close a long period of discussions between the Laboratory and the Authorising Departments (HMIP and MAFF). Draft certificates of authorisation were sent out to local public bodies for consultation in the autumn and the final certificates were in place ready for implementation on the 1st January 1992. Further details are given in the body of this report. (author)

  5. Numerical modelling of barrier discharge

    International Nuclear Information System (INIS)

    Kozlov, K.V.

    1990-01-01

    A survey is given of the theory of the barrier discharge in oxygen at atmospheric pressure. The discharge consists of a number of randomly distributed microdischarges of nanosecond duration. This complicated space-time structure must be taken into account in any numerical model of the barrier discharge. In a single discharge channel, three consequent phases can be distinguished; 1) electric breakdown and electron-time-scale processes; 2) ion drift and ion-time-scale processes; 3) slow chemical processes, diffusion of chemical products and heat transfer. The scheme of such a three-phase model is presented and the results of simulation are discussed and compared with experimental data. (J.U.) 9 figs., 15 refs

  6. Gram stain of urethral discharge

    Science.gov (United States)

    Urethral discharge Gram stain; Urethritis - Gram stain ... Augenbraun MH, McCormack WM. Urethritis. In: Bennett JE, Dolin R, Blaser MJ, eds. Mandell, Douglas, and Bennett's Principles and Practice of Infectious Diseases, Updated Edition . ...

  7. Discharge cell for ozone generator

    Science.gov (United States)

    Nakatsuka, Suguru

    2000-01-01

    A discharge cell for use in an ozone generator is provided which can suppress a time-related reduction in ozone concentration without adding a catalytic gas such as nitrogen gas to oxygen gas as a raw material gas. The discharge cell includes a pair of electrodes disposed in an opposed spaced relation with a discharge space therebetween, and a dielectric layer of a three-layer structure consisting of three ceramic dielectric layers successively stacked on at least one of the electrodes, wherein a first dielectric layer of the dielectric layer contacting the one electrode contains no titanium dioxide, wherein a second dielectric layer of the dielectric layer exposed to the discharge space contains titanium dioxide in a metal element ratio of not lower than 10 wt %.

  8. Total colectomy or proctocolectomy - discharge

    Science.gov (United States)

    ... Ileostomy and your diet Ileostomy - caring for your stoma Ileostomy - changing your pouch Ileostomy - discharge Ileostomy - what to ask your doctor Low-fiber diet Surgical wound care - open Types of ileostomy Review Date 9/17/ ...

  9. [Postoperative patterns of improvement of symptoms and degrees of satisfaction in families of patients after operations for definite idiopathic normal pressure hydrocephalus: a long-term follow-up study].

    Science.gov (United States)

    Takeuchi, Totaro; Goto, Hiromi; Izaki, Kenji; Tamura, Shinya; Sasanuma, Zinichi; Maeno, Kazushige; Kikuchi, Yasuhiro; Tomii, Masato; Koizumi, Zinichi; Watanabe, Zenichiro; Numazawa, Shinichi; Ito, Yasunobu; Ohara, Hiroo; Kowada, Masayoshi; Watanabe, Kazuo

    2007-08-01

    To clarify the patterns of improvement of pre- and post-operative symptoms and family satisfaction in patients with definite idiopathic normal pressure hydrocephalus (iNPN) who responded well to shunt intervention. The subjects included 40 patients definitively diagnosed with iNPH and who were followed up for one year or longer (age, 61-85; male-to-female ratio, 18: 22). The study focused on (1) preoperative clinical symptoms, (2) improvements in symptoms at 1, 3, 5, and 12 months after surgery, and the satisfaction of the families based on medical results of the Zarit caregiver burden interview, and infomation through questionnaires to medical personnel. (1) The major symptoms were gait disturbance (G, n=38), dementia (D, n=10), and urinary incontinence (U, n=23). G and D appeared as initial symptoms in 30 and 10 cases, respectively. (2) The rates of postoperative improvement at 1, 3, 5, and 12 months were 94.7%, 94.7%, 97.4%, and 94.7% for G, 43.8%, 62.5%, 71.9%, and 84.4% for D, and 78.3%, 86.96%, 86.96%, and 91.3% for U, respectively. G and U cases improved during the postoperative early stage, and D improved gradually from after the third postoperative month. The family satisfaction before surgery and at 1, 3, 5, and 12 months after surgery was 72.5 +/- 12.8, 68.1 +/- 15.4, 55.7 +/- 9.6, 52.9 +/- 11.4, and 47.3 +/- 7.9 points, respectively. The rate of improvement in satisfaction was higher for D. The satisfaction of the medical personnel was 88 percent (+) at 1 month and tended to remain high for 12 months. (1) Preoperative gait disturbance is a major initial symptom in definitively diagnosed iNPN. (2) Postoperative improvement of G and U is obtained at an early stage. In contrast, D tends to improve gradually from after the third postoperative month. The family satisfaction increases as the symptom of D improve. The satisfaction of the medical personnel tends to remain high after the first postoperative month. This study investigated the results of

  10. Radioactive discharges from Sellafield (UK)

    International Nuclear Information System (INIS)

    Pentreath, R.J.

    1985-01-01

    This study of low-level liquid radioactive discharges from the British Nuclear Fuels Ltd Sellafield site into the eastern basin of the Irish Sea, prepared on the basis of existing publications and documents, reviews chemical forms and rate of discharges, physical oceanography, sediment distribution and fisheries of the Irish Sea, behaviour of radionuclides in seawater, association with sedimentary materials, accumulation of radionuclides by biological materials, environmental monitoring, surveillance and assessment of radiation exposure of the public and impact on the environment

  11. State waste discharge permit application, 200-E chemical drain field

    International Nuclear Information System (INIS)

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect ground would be subject to permitting under the structure of Chapter 173-216 (or 173-218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Department of Energy, Richland Operations Office entered into Consent Order No. DE 91NM-177, (Ecology and DOE-RL 1991). The Consent Order No. DE 91NM-177 requires a series of permitting activities for liquid effluent discharges. This document presents the State Waste Discharge Permit (SWDP) application for the 200-E Chemical Drain Field. Waste water from the 272-E Building enters the process sewer line directly through a floor drain, while waste water from the 2703-E Building is collected in two floor drains, (north and south) that act as sumps and are discharged periodically. The 272-E and 2703-E Buildings constitute the only discharges to the process sewer line and the 200-E Chemical Drain Field

  12. State waste discharge permit application, 200-E chemical drain field

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect ground would be subject to permitting under the structure of Chapter 173-216 (or 173-218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Department of Energy, Richland Operations Office entered into Consent Order No. DE 91NM-177, (Ecology and DOE-RL 1991). The Consent Order No. DE 91NM-177 requires a series of permitting activities for liquid effluent discharges. This document presents the State Waste Discharge Permit (SWDP) application for the 200-E Chemical Drain Field. Waste water from the 272-E Building enters the process sewer line directly through a floor drain, while waste water from the 2703-E Building is collected in two floor drains, (north and south) that act as sumps and are discharged periodically. The 272-E and 2703-E Buildings constitute the only discharges to the process sewer line and the 200-E Chemical Drain Field.

  13. Ballooning stability of JET discharges

    International Nuclear Information System (INIS)

    Huysmans, G.T.A.; Goedbloed, J.P.; Galvao, R.M.O.; Lazzaro, E.; Smeulders, P.

    1989-01-01

    Conditions under which ballooning modes are expected to be excited have recently been obtained in two different types of discharges in JET. In the first type, extremely large pressure gradients have been produced in the plasma core through pellet injections in the current rise phase followed by strong additional heating. In the second type, the total pressure of the discharge is approaching the Troyon limit. The stability of these discharges with respect to the ideal MHD ballooning modes has been studied with the stability code HBT. The equilibria are reconstructed with the IDENTC code using the external magnetic measurements and the experimental pressure profile. The results show that the evaluated high beta discharge is unstable in the central region of the plasma. This instability is related to the low shear and not to a large pressure gradient, as expected at the Troyon limit. In the pellet discharges the regions with the large pressure gradients are unstable to ballooning modes at the time of the beta decay, which ends the period of enhanced performance. The maximum pressure gradient in these discharges is limited by the boundary of the first region of stability. The observed phenomena at the beta decay are similar to those observed at the beta limit in DIII-D and TFTR. (author)

  14. Stochastic evaluation of mass discharge from pointlike concentration measurements

    Science.gov (United States)

    Schwede, Ronnie L.; Cirpka, Olaf A.

    2010-01-01

    The contaminant mass discharge crossing a control plane is an important metric in the assessment of natural attenuation at contaminated sites. For risk-assessment purposes, the mass discharge must be estimated together with a level of uncertainty. We present a conditional Monte Carlo approach that allows estimating the statistical distribution of mass discharge. The approach is based on conditioning multiple realizations of the hydraulic conductivity field on all data available. We jointly determine a first-order decay coefficient in each realization, leading to conditional statistical distributions of all estimated parameters and the total mass discharge. The resulting statistical distribution of contaminant mass discharges can be used in the assessment of risks at the contaminated site. The method is applied to data of hypothetical test cases, which gives the opportunity to compare estimation results to the true field. As concentration data, we account for pointlike measurements obtained in multi-level sampling wells. The obtained empirical distribution of mass discharge crossing the multi-level sampling fence could be well fitted by a log-normal distribution.

  15. nth roots of normal contractions

    International Nuclear Information System (INIS)

    Duggal, B.P.

    1992-07-01

    Given a complex separable Hilbert space H and a contraction A on H such that A n , n≥2 some integer, is normal it is shown that if the defect operator D A = (1 - A * A) 1/2 is of the Hilbert-Schmidt class, then A is similar to a normal contraction, either A or A 2 is normal, and if A 2 is normal (but A is not) then there is a normal contraction N and a positive definite contraction P of trace class such that parallel to A - N parallel to 1 = 1/2 parallel to P + P parallel to 1 (where parallel to · parallel to 1 denotes the trace norm). If T is a compact contraction such that its characteristics function admits a scalar factor, if T = A n for some integer n≥2 and contraction A with simple eigen-values, and if both T and A satisfy a ''reductive property'', then A is a compact normal contraction. (author). 16 refs

  16. Classification of electrical discharges in DC Accelerators

    Science.gov (United States)

    Banerjee, Srutarshi; Deb, A. K.; Rajan, Rehim N.; Kishore, N. K.

    2016-08-01

    Controlled electrical discharge aids in conditioning of the system while uncontrolled discharges damage its electronic components. DC Accelerator being a high voltage system is no exception. It is useful to classify electrical discharges according to the severity. Experimental prototypes of the accelerator discharges are developed. Photomultiplier Tubes (PMTs) are used to detect the signals from these discharges. Time and Frequency domain characteristics of the detected discharges are used to extract features. Machine Learning approaches like Fuzzy Logic, Neural Network and Least Squares Support Vector Machine (LSSVM) are employed to classify the discharges. This aids in detecting the severity of the discharges.

  17. Classification of electrical discharges in DC Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Srutarshi, E-mail: sruban.stephens@gmail.com [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Deb, A.K. [Department of Electrical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302 (India); Rajan, Rehim N. [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Kishore, N.K. [Department of Electrical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302 (India)

    2016-08-11

    Controlled electrical discharge aids in conditioning of the system while uncontrolled discharges damage its electronic components. DC Accelerator being a high voltage system is no exception. It is useful to classify electrical discharges according to the severity. Experimental prototypes of the accelerator discharges are developed. Photomultiplier Tubes (PMTs) are used to detect the signals from these discharges. Time and Frequency domain characteristics of the detected discharges are used to extract features. Machine Learning approaches like Fuzzy Logic, Neural Network and Least Squares Support Vector Machine (LSSVM) are employed to classify the discharges. This aids in detecting the severity of the discharges.

  18. An Apparatus for Measuring Rates of Discharge of a Fuel-Injection System

    Science.gov (United States)

    Dutee, Francis J

    1941-01-01

    A portable apparatus for rapidly determining rates of discharge of a fuel-injection system is described. Satisfactory operation of this apparatus with injection-pump speeds up to 2400 r.p.m was obtained. Rate-of-discharge tests were made with several cam-plunger-valve injection systems with long injection tubes. A check valve designed to reduce secondary discharges was tested. This check valve was operated with injection-pump speeds up to 2400 r.p.m without the occurrence of large secondary discharges.

  19. Propagation of Partial Discharge and Noise Pulses in Turbine Generators

    DEFF Research Database (Denmark)

    Henriksen, Mogens; Stone, G. C.; Kurtz, M.

    1986-01-01

    Changes with time in the partial discharge (PD) activity originating in a generator stator's insulation system provide information about the electrical integrity of the stator winding. It is desirable to measure PD during normal service to minimize costs. To do this successfully, the influence...... of electrical interference must be reduced. Tests are reported which characterize the nature of discharge and noise pulses when using capacitive couplers mounted on each of the phase leads and an RF current transformer mounted on the neutral lead for signal detection. Significant differences between PD...... and electrical noise have been observed....

  20. Evaluation of stream discharges measurement using radioisotope and conventional method at Sungai Weng catchment area, Kedah

    International Nuclear Information System (INIS)

    Nazrul Hizam Yusoff and Wan Zakaria Wan MuhdTahir

    2006-01-01

    A number of discharge measurements using radioisotope and current metering techniques at selected streams in Sg. Weng Experimental Catchment were conducted by MINT and JPS gauging teams starting from 2003-2005. This study aims to prepare stage-discharge relationships or rating curves of the selected streams during variable flow conditions. The rating curve of the stream is one of the important parameters and usually appraised in certain routine operations of hydrological studies. It may be used in the planning of water resources management and flood control scheme. The radioisotope method employed in this study involved the injection of short-lived radioisotope tracer, that is, technetium-99m ( 99m Tc having its half-life ∼ 6.023 hrs) which was supplied from a high activity technetium generator (55.5 Gbq). Measurement of stream discharges were concurrently undertaken by JPS staff using a current meter type 0TT-C2 mounted on a wading rod at selected gauging stations for comparison purposes. Methodologies from the two methods of discharge measurements, comparison of results and identifying the uncertainties (errors) in performing the measurement during low, medium and high turbulent flows were explained in this paper. Generally, the entire results of streamflow data (2003-2005) measured by both methods during low flows (Q 3 /s) exhibit almost comparable values to each other. However, for moderate flows (1.0 m 3 /s 3 /s), the different in gauging results are slightly higher using radioisotope method ( i.e. Q isotope > Q current meter and may goes up to 40%) , and during high turbulent flows (Q>6.0 m 3 /s) the radioisotope method presented more than 40% higher discharge values as compared to the measurement made by the conventional current-meter. Observation made on site anticipated that inaccurate gauging data measured by conventional means during high flow and turbulent conditions are expected. The average estimated measurement error associated with isotope method

  1. Characterization of the flowing afterglows of an N{sub 2}-O{sub 2} reduced-pressure discharge: setting the operating conditions to achieve a dominant late afterglow and correlating the NO{sub {beta}} UV intensity variation with the N and O atom densities

    Energy Technology Data Exchange (ETDEWEB)

    Boudam, M K [Groupe de Physique des Plasmas, Universite de Montreal, CP 6128, Succursale Centre-Ville, Montreal H3C 3J7, Quebec (Canada); Saoudi, B [Groupe de Physique des Plasmas, Universite de Montreal, CP 6128, Succursale Centre-Ville, Montreal H3C 3J7, Quebec (Canada); Moisan, M [Groupe de Physique des Plasmas, Universite de Montreal, CP 6128, Succursale Centre-Ville, Montreal H3C 3J7, Quebec (Canada); Ricard, A [Centre de Physique Atomique de Toulouse (CPAT), 118, route de Narbonne, Universite Paul Sabatier, 31062-Toulouse (France)

    2007-03-21

    The flowing afterglow of an N{sub 2}-O{sub 2} discharge in the 0.6-10 Torr range is examined in the perspective of achieving sterilization of medical devices (MDs) under conditions ensuring maximum UV intensity with minimum damage to polymer-based MDs. The early afterglow is shown to be responsible for creating strong erosion damage, requiring that the sterilizer be operated in a dominant late-afterglow mode. These two types of afterglow can be characterized by optical emission spectroscopy: the early afterglow is distinguished by an intense emission from the N{sub 2}{sup +} 1st negative system (band head at 391.4 nm) while the late afterglow yields an overpopulation of the v' = 11 ro-vibrational level of the N{sub 2}(B) state, indicating a reduced contribution from the early afterglow N{sub 2} metastable species. We have studied the influence of operating conditions (pressure, O{sub 2} content in the N{sub 2}-O{sub 2} mixture, distance of the discharge from the entrance to the afterglow (sterilizer) chamber) in order to achieve a dominant late afterglow that also ensures maximum and almost uniform UV intensity in the sterilization chamber. As far as operating conditions are concerned, moving the plasma source sufficiently far from the chamber entrance is shown to be a practical means for significantly reducing the density of the characteristic species of the early afterglow. Using the NO titration method, we obtain the (absolute) densities of N and O atoms in the afterglow at the NO injection inlet, a few cm before the chamber entrance: the N atom density goes through a maximum at approximately 0.3-0.5% O{sub 2} and then decreases, while the O atom density increases regularly with the O{sub 2} percentage. The spatial variation of the N atom (relative) density in the chamber is obtained by recording the emission intensity from the 1st positive system at 580 nm: in the 2-5 Torr range, this density is quite uniform everywhere in the chamber. The (relative

  2. Estimating sediment discharge: Appendix D

    Science.gov (United States)

    Gray, John R.; Simões, Francisco J. M.

    2008-01-01

    Sediment-discharge measurements usually are available on a discrete or periodic basis. However, estimates of sediment transport often are needed for unmeasured periods, such as when daily or annual sediment-discharge values are sought, or when estimates of transport rates for unmeasured or hypothetical flows are required. Selected methods for estimating suspended-sediment, bed-load, bed- material-load, and total-load discharges have been presented in some detail elsewhere in this volume. The purposes of this contribution are to present some limitations and potential pitfalls associated with obtaining and using the requisite data and equations to estimate sediment discharges and to provide guidance for selecting appropriate estimating equations. Records of sediment discharge are derived from data collected with sufficient frequency to obtain reliable estimates for the computational interval and period. Most sediment- discharge records are computed at daily or annual intervals based on periodically collected data, although some partial records represent discrete or seasonal intervals such as those for flood periods. The method used to calculate sediment- discharge records is dependent on the types and frequency of available data. Records for suspended-sediment discharge computed by methods described by Porterfield (1972) are most prevalent, in part because measurement protocols and computational techniques are well established and because suspended sediment composes the bulk of sediment dis- charges for many rivers. Discharge records for bed load, total load, or in some cases bed-material load plus wash load are less common. Reliable estimation of sediment discharges presupposes that the data on which the estimates are based are comparable and reliable. Unfortunately, data describing a selected characteristic of sediment were not necessarily derived—collected, processed, analyzed, or interpreted—in a consistent manner. For example, bed-load data collected with

  3. Glow discharge in singlet oxygen

    International Nuclear Information System (INIS)

    Vagin, N.P.; Ionin, A.A.; Klimachev, Yu.M.; Sinitsyn, D.V.; Yuryshev, N.N.; Kochetov, I.V.; Napartovich, A.P.

    2003-01-01

    Currently, there is no experimental data on the plasma balance in gas mixtures with a high content of singlet delta oxygen O 2 ( 1 Δ g ). These data can be obtained by studying the parameters of an electric discharge in singlet oxygen produced by a chemical generator. The O 2 ( 1 Δ g ) molecules significantly change the kinetics of electrons and negative ions in plasma. Hence, the discharge conditions at low and high O 2 ( 1 Δ g ) concentrations are very different. Here, the parameters of the positive column of a glow discharge in a gas flow from a chemical singlet-oxygen generator are studied. It is experimentally shown that, at an O 2 ( 1 Δ g ) concentration of 50% and at pressures of 1.5 and 2 torr, the electric field required to sustain the discharge is considerably lower than in the case when all of the oxygen molecules are in the ground state. A theoretical model of the glow discharge is proposed whose predictions are in good agreement with the experimental data

  4. Analysis for discharge-radiation dynamics in alternating current plasma display panels

    International Nuclear Information System (INIS)

    Suzuki, Keizo; Yamamoto, Kenichi; Kajiyama, Hiroshi; Ho, Shirun; Uemura, Norihiro; Muraoka, Katsunori

    2004-01-01

    An analytical method to study the discharge-radiation dynamics (DRD) in alternating current plasma display panels was developed. The input parameters for this DRD analysis were experimentally determined panel voltage and current wave forms. Discharge voltage, current, and power wave forms in the discharge volume of a cell were first obtained from the measured panel voltage and current wave forms using known geometrical configurations and electric circuit calculations. Intrinsic discharge parameters, such as electron temperature and density, were then determined to satisfy these discharge wave forms under the assumption of a hydrodynamic approach. A one-dimensional discharge structure with two regions (cathode fall and positive column) and several other assumptions which are plausible from the discharge physics point of view were also adopted. These assumptions took account of known cross sections and energies of electron-impact excitation and ionization of discharge gas atoms, and a secondary electron emission coefficient of the dielectric surface at the cathode side induced by ion bombardment. Radiation intensities from the discharge were calculated using the determined intrinsic discharge parameters, and the results were compared with those measured for the respective panel conditions used in the calculations, yielding a fair agreement. The luminous efficiency, defined as the radiation intensity divided by the discharge power, was also determined using the intrinsic discharge parameters. Discussion on the luminous efficiency change for different panel operating conditions revealed that the efficiency improvement at a lower voltage was attributable to a lower electron temperature for this condition

  5. MicroSAINT Models of the Close-In Weapon System (CIWS): Sensitivity Studies and Conformal Mapping of Performance Data (CISWENS). Subtitle: Exploring the Utility MicroSAINT Models: CIWS Loading Operation Models Under Normal and MOPP IV Conditions

    Science.gov (United States)

    1991-05-31

    operation is, in some sense, understaffed. Thus, if everything worked like clockwork , the loading operation was completed quickly. Otherwise a delay in...and so forth so that one risks mixing ’apples and oranges ’. Second, there ik no control over the range of variables represented in such a database

  6. The efficacy of normal saline irrigation to prevent surgical site infection

    International Nuclear Information System (INIS)

    Ashraf, V.; Awan, A.S.

    2015-01-01

    The efficacy of normal saline irrigation to prevent surgical site Infection The aim of the study was to evaluate the efficacy of normal saline irrigations to prevent surgical site infection (SSI). Study Design: A comparative study. Place and Duration of Study: The study was conducted at surgery and gynecology Dept CMH Chunian from 1st Jan 2012 to 1st Nov 2012. Patients and Methods: Two hundred clean surgical and gynecological cases were included in the study. Hundred cases which were randomly selected had their wound washed with warm normal saline for 60 sec and then mopped dry with clean swabs. Subcuticular Stitches were applied to all the 200 cases. The surgical wounds were examined on 3rd post operative day and then finally on 15th post operative day. Patients with wound infection developed pain at the operation site and fever on third post operative day. Wounds were examined for swelling, redness, discharge and stitch abscess. Routine investigations were done as per protocol. Wound swabs were taken for culture and sensitivity. Results: The study was carried out on 200 clean cases (general and gynecological). They were 130 females and 70 males. The 100 cases whose wounds were washed with normal saline only 1 patient developed wound infection while in the other group who did not had saline irrigations 8 patients out of 100 developed wound infection. The commonest infective organisms were staphylococcus aureus and the other organisms were streptococcus pyogenes, proteus, Klaebsiella, E coli and pseudomonas. No MRSA was detected. Conclusion: In our study washing the wound with warm normal saline for 60 seconds resulted in the wound being infection free. Wound infection is associated with delayed wound healing, prolonged hospital stay and increased economic pressure on the patient and on the state. (author)

  7. Detection of metal contaminants in seawater by spectral analysis of microarc discharge

    Science.gov (United States)

    Gamaleev, Vladislav; Furuta, Hiroshi; Hatta, Akimitsu

    2018-01-01

    In this work, we analyzed the discharge process and optical emission spectra from the microarc discharges operated in three types of highly conductive liquids: artificial seawater with 10 main components, reference solutions each containing a single component, and a standard Fe solution. Microarc discharges were operated at a low breakdown voltage (below 600 V) using a needle-to-plate electrode system immersed in each liquid in a quartz cuvette. Optical emission spectra were collected from discharges ignited in each liquid. Owing to the complex composition of seawater, spectra from discharges in different liquids were compared to assign the emission peaks. The proposed method showed good potential for the detection of Fe and other metals in seawater. Using the present setup, it was possible to detect Fe impurities at a concentration of 300 ppm. The possibility of using atomic emission spectroscopy of microarc discharges in seawater for on-site elemental composition analysis has been demonstrated.

  8. Ultraviolet radiation induced discharge laser

    Science.gov (United States)

    Gilson, Verle A.; Schriever, Richard L.; Shearer, James W.

    1978-01-01

    An ultraviolet radiation source associated with a suitable cathode-anode electrode structure, disposed in a gas-filled cavity of a high pressure pulsed laser, such as a transverse electric atmosphere (TEA) laser, to achieve free electron production in the gas by photoelectric interaction between ultraviolet radiation and the cathode prior to the gas-exciting cathode-to-anode electrical discharge, thereby providing volume ionization of the gas. The ultraviolet radiation is produced by a light source or by a spark discharge.

  9. 33 CFR 154.545 - Discharge containment equipment.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Equipment Requirements § 154... chapter may be utilized in the planning requirements of subpart F and subpart H of this part. [CGD 75-124... material and equipment to contain any oil or hazardous material discharged on the water from operations at...

  10. 46 CFR 14.307 - Entries on certificate of discharge.

    Science.gov (United States)

    2010-10-01

    ... operating company, official number of the vessel, class of the vessel, and the nature of the voyage. (b... to the mariner. (d) Except as directed by § 14.313, the shipping company shall keep both copies of the certificate. (e) The company shall provide copies of certificates of discharge to the mariner and...

  11. Mathematical expression of discharge capacity of compound open ...

    Indian Academy of Sciences (India)

    splines (MARS) techniques were utilised to estimate the discharge capacity of compound open channels ... attempted to utilise these methods to estimate flow ..... After definition of model structure, training algorithm should be considered. Training here implies adjusting the values of weights and biases. This operation is ...

  12. Effects of corona discharge treatment on some properties of wool ...

    African Journals Online (AJOL)

    The scanning electron microscope (SEM) showed that a number of scales on the surface epicuticle wool have dropped. The fourier transform infrared (FT-IR) analysis indicated that the rate of oxygen levels of wool increased and the rate of sulfur decreased after the operation. Key words: Corona discharge, wool fabric, ...

  13. 40 CFR 1700.4 - Discharges requiring control.

    Science.gov (United States)

    2010-07-01

    ... training, testing, or maintenance operations. (b) Catapult Water Brake Tank & Post-Launch Retraction... seawater. (j) Elevator Pit Effluent: the liquid that accumulates in, and is discharged from, the sumps of elevator wells on vessels. (k) Firemain Systems: the seawater pumped through the firemain system for...

  14. Improved plasma uniformity in a discharge system with electron injection.

    Science.gov (United States)

    Vizir, A V; Tyunkov, A V; Shandrikov, M V

    2009-02-01

    We present the results of experiments leading to improvement in bulk plasma uniformity of a constricted-arc discharge system with electron injection. The steady-state discharge was in argon, at a gas pressure of 0.5 mTorr, and operated with a main discharge voltage between 20 and 100 V and current between 3 and 15 A. The radial plasma distribution was measured with a movable Langmuir probe. We find that geometric modification of the intermediate electrode exit aperture and the main discharge cathode add little to the plasma uniformity. Improved bulk plasma uniformity is observed when a special distributing grid electrode is used and the main discharge voltage is less than 20-30 V. The application of a weakly divergent magnetic field in the region of the intermediate electrode exit aperture decreases the plasma nonuniformity from 20% to 14% over a radial distance of 30 cm. The plasma uniformity was further improved by compensating the magnetic self-field of the injected electron beam by a reverse magnetic field produced with a special electrode compensator. It is shown that an increase in discharge current causes a proportional increase in back current in the distributing electrode. The approach allows a decrease in plasma nonuniformity from 20% to 13% over a radial distance of 30 cm.

  15. The Normal-incidence Vacuum-ultraviolet Spectrometer for the TJ-II and First Experimental Results

    International Nuclear Information System (INIS)

    McCarthy, K. J.; Zurro, B.; Baciero, A.

    2002-01-01

    A normal-incidence spectrometer, operating in the extreme-ultraviolet and ultraviolet wavelength regions, has been commissioned for the TJ-II stellarator. The instrument has been custom built by McPherson, Chelmsford, MA, and has several unique features and accessories that are described here. The instrument and CCD detector has been tested and calibrated, and its performance evaluated, using spectral lines from glow discharges and a RF excited flow lamp. Finally, the first spectra collected with the instrument of TJ-II plasmas are presented and a preliminary estimation of an oxygen ion temperature is made. (Author) 23 refs

  16. The Normal-incidence Vacuum-ultraviolet Spectrometer for the TJ-II and First Experimental Results

    Energy Technology Data Exchange (ETDEWEB)

    McCarthy, K.J.; Zurro, B.; Baciero, A.

    2002-07-01

    A normal-incidence spectrometer, operating in the extreme-ultraviolet and ultraviolet wavelength regions, has been commissioned for the TJ-II stellarator. The instrument has been custom built by McPherson, Chelmsford, MA, and has several unique features and accessories that are described here. The instrument and CCD detector has been tested and calibrated, and its performance evaluated, using spectral lines from glow discharges and a RF excited flow lamp. Finally, the first spectra collected with the instrument of TJ-II plasmas are presented and a preliminary estimation of an oxygen ion temperature is made. (Author) 23 refs.

  17. Air corona discharge chemical kinetics

    International Nuclear Information System (INIS)

    Kline, L.E.; Kanter, I.E.

    1984-01-01

    We have theoretically studied the initial chemical processing steps which occur in pulseless, negative, dc corona discharges in flowing air. A rate equation model is used because these discharges consist of a very small ionization zone near the pin with most of the pin-plane gap filled by a drift zone where both the electric field and the electron density are relatively uniform. The primary activated species are N 2 (A),O and O 2 (a 1 Δ). The predicted activated species density due to one discharge is 100 ppm per ms . mA cm 2 assuming E/n=60 Td. In pure, dry air the final product due to these activated species is primarily O 3 . The NO /sub x/ production is about 0.5 ppm per mA. In moist air there is an additional production of about 1.5 ppm per mA of HO /sub x/ species. The predicted ozone formation reactions will be ''intercepted'' when impurities are present in the air. Impurities present at densities below about 0.1% will react primarily with the activated species rather than with electrons. Hence the predicted activated species density provides an estimate of the potential chemical processing performance of the discharge

  18. Discharge measurements at gaging stations

    Science.gov (United States)

    Turnipseed, D. Phil; Sauer, Vernon B.

    2010-01-01

    The techniques and standards for making discharge measurements at streamflow gaging stations are described in this publication. The vertical axis rotating-element current meter, principally the Price current meter, has been traditionally used for most measurements of discharge; however, advancements in acoustic technology have led to important developments in the use of acoustic Doppler current profilers, acoustic Doppler velocimeters, and other emerging technologies for the measurement of discharge. These new instruments, based on acoustic Doppler theory, have the advantage of no moving parts, and in the case of the acoustic Doppler current profiler, quickly and easily provide three-dimensional stream-velocity profile data through much of the vertical water column. For much of the discussion of acoustic Doppler current profiler moving-boat methodology, the reader is referred to U.S. Geological Survey Techniques and Methods 3-A22 (Mueller and Wagner, 2009). Personal digital assistants (PDAs), electronic field notebooks, and other personal computers provide fast and efficient data-collection methods that are more error-free than traditional hand methods. The use of portable weirs and flumes, floats, volumetric tanks, indirect methods, and tracers in measuring discharge are briefly described.

  19. Discharge cleaning of carbon deposits

    International Nuclear Information System (INIS)

    Mozetic, M.; Vesel, A.; Drenik, A.

    2006-01-01

    Experimental results of discharge cleaning of carbon deposits are presented. Deposits were prepared by creating plasma in pure methane. The methane was cracked in RF discharge at the output power of 250 W. The resultant radicals were bonded to the wall of discharge vessel forming a thin film of hydrogenated black carbon with the thickness of about 200nm. The film was then cleaned in situ by oxygen plasma with the density of about 1x10 16 m -3 , electron temperature of 5 eV, neutral gas kinetic temperature of about 100 0 C and neutral atom density of 6x10 21 m -3 . The treatment time was 30 minutes. The efficiency of plasma cleaning was monitored by optical emission spectroscopy. As long as the wall was contaminated with carbon deposit, substantial emission of the CO molecules was detected. As the cleaning was in progress, the CO emission was decreasing and vanished after 30 minutes when the discharge vessel became free of any carbon. The results are explained by interaction of plasma radicals with carbon deposits. (author)

  20. Three modes of a direct-current plasma jet operated underwater to degrade methylene blue

    Science.gov (United States)

    Xuechen, LI; Biao, WANG; Pengying, JIA; Linwei, YANG; Yaru, LI; Jingdi, CHU

    2017-11-01

    A direct-current air plasma jet operated underwater presents three stable modes including an intermittently-pulsed discharge, a periodically-pulsed discharge and a continuous discharge with increasing the power voltage. The three discharge modes have different appearances for the plasma plumes. Moreover, gap voltage-current characteristics indicate that the continuous discharge is in a normal glow regime. Spectral lines from reactive species (OH, N2, N2 +, H α , and O) have been revealed in the emission spectrum of the plasma jet operated underwater. Spectral intensities emitted from OH radical and oxygen atom increase with increasing the power voltage or the gas flow rate, indicating that reactive species are abundant. These reactive species cause the degradation of the methylene blue dye in solution. Effects of the experimental parameters such as the power voltage, the gas flow rate and the treatment time are investigated on the degradation efficiency. Results indicate that the degradation efficiency increases with increasing the power voltage, the gas flow rate or the treatment time. Compared with degradation in the intermittently-pulsed mode or the periodically-pulsed one, it is more efficient in the continuous mode, reaching 98% after 21 min treatment.

  1. Post-operative recovery profile after laparoscopic cholecystectomy: a prospective, observational study of a multimodal anaesthetic regime

    DEFF Research Database (Denmark)

    Jensen, K; Kehlet, H; Lund, Claus

    2007-01-01

    BACKGROUND: Laparoscopic cholecystectomy is now often an ambulatory procedure, but dependent on short-term post-operative complaints of pain and post-operative nausea and vomiting (PONV). The efficacy of post-anaesthesia care units (PACUs) is therefore important to facilitate return to normal...... functions. We investigated the feasibility and efficacy of a standardized, evidence-based anaesthesia/analgesic regime to identify residual problems in the early post-operative phase. METHODS: One hundred and thirty-four consecutive patients admitted for elective laparoscopic cholecystectomy at Hvidovre...... to discharge (mean, 88 min). There were on average 2.7 treatment interventions (range, 0-11) before discharge. CONCLUSION: An evidence-based, multimodal approach to the anaesthetic/analgesic management in laparoscopic cholecystectomy is feasible and advantageous in the early post-operative phase. Pain and PONV...

  2. Post-operative recovery profile after laparoscopic cholecystectomy: a prospective, observational study of a multimodal anaesthetic regime

    DEFF Research Database (Denmark)

    Jensen, K; Kehlet, H; Lund, Claus Michael

    2007-01-01

    to discharge (mean, 88 min). There were on average 2.7 treatment interventions (range, 0-11) before discharge. CONCLUSION: An evidence-based, multimodal approach to the anaesthetic/analgesic management in laparoscopic cholecystectomy is feasible and advantageous in the early post-operative phase. Pain and PONV......BACKGROUND: Laparoscopic cholecystectomy is now often an ambulatory procedure, but dependent on short-term post-operative complaints of pain and post-operative nausea and vomiting (PONV). The efficacy of post-anaesthesia care units (PACUs) is therefore important to facilitate return to normal...... functions. We investigated the feasibility and efficacy of a standardized, evidence-based anaesthesia/analgesic regime to identify residual problems in the early post-operative phase. METHODS: One hundred and thirty-four consecutive patients admitted for elective laparoscopic cholecystectomy at Hvidovre...

  3. Vagina: What's Normal, What's Not

    Science.gov (United States)

    ... until after your baby is born. During pregnancy, vaginal discharge often increases. Vaginal tears are relatively common during ... syphilis and genital herpes. Signs might include abnormal vaginal discharge or genital sores. Vaginitis. An infection or change ...

  4. One-dimensional Numerical Model of Transient Discharges in Air of a Spatial Plasma Ignition Device

    Science.gov (United States)

    Saceleanu, Florin N.

    This thesis examines the modes of discharge of a plasma ignition device. Oscilloscope data of the discharge voltage and current are analyzed for various pressures in air at ambient temperature. It is determined that the discharge operates in 2 modes: a glow discharge and a postulated streamer discharge. Subsequently, a 1-dimensional fluid simulation of plasma using the finite volume method (FVM) is developed to gain insight into the particle kinetics. Transient results of the simulation agree with theories of electric discharges; however, quasi-steady state results were not reached due to high diffusion time of ions in air. Next, an ordinary differential equation (ODE) is derived to understand the discharge transition. Simulated results were used to estimate the voltage waveform, which describes the ODE's forcing function; additional simulated results were used to estimate the discharge current and the ODE's non-linearity. It is found that the ODE's non-linearity increases exponentially for capacitive discharges. It is postulated that the non-linearity defines the mode transition observed experimentally. The research is motivated by Spatial Plasma Discharge Ignition (SPDI), an innovative ignition system postulated to increase combustion efficiency in automobile engines for up to 9%. The research thus far can only hypothesize SPDI's benefits on combustion, based on the literature review and the modes of discharge.

  5. Accumulated frailty characteristics predict postoperative discharge institutionalization in the geriatric patient.

    Science.gov (United States)

    Robinson, Thomas N; Wallace, Jeffrey I; Wu, Daniel S; Wiktor, Arek; Pointer, Lauren F; Pfister, Shirley M; Sharp, Terra J; Buckley, Mary J; Moss, Marc

    2011-07-01

    Frailty is a state of increased vulnerability to health-related stressors and can be measured by summing the number of frailty characteristics present in an individual. Discharge institutionalization (rather than discharge to home) represents disease burden and functional dependence after hospitalization. Our aim was to determine the relationship between frailty and need for postoperative discharge institutionalization. Subjects ≥ 65 years undergoing major elective operations requiring postoperative ICU admission were enrolled. Discharge institutionalization was defined as need for institutionalized care at hospital discharge. Fourteen preoperative frailty characteristics were measured in 6 domains: comorbidity burden, function, nutrition, cognition, geriatric syndromes, and extrinsic frailty. A total of 223 subjects (mean age 73 ± 6 years) were studied. Discharge institutionalization occurred in 30% (n = 66). Frailty characteristics related to need for postoperative discharge institutionalization included: older age, Charlson index ≥ 3, hematocrit institutionalization. An increased number of frailty characteristics present in any one subject resulted in increased rate of discharge institutionalization. Nearly 1 in 3 geriatric patients required discharge to an institutional care facility after major surgery. The frailty characteristics of prolonged up-and-go and any functional dependence were most closely related to the need for discharge institutionalization. Accumulation of a higher number of frailty characteristics in any one geriatric patient increased their risk of discharge institutionalization. Published by Elsevier Inc.

  6. 33 CFR 159.309 - Limitations on discharge of treated sewage or graywater.

    Science.gov (United States)

    2010-07-01

    ... treated sewage or graywater. 159.309 Section 159.309 Navigation and Navigable Waters COAST GUARD... Certain Alaskan Waters by Cruise Vessel Operations § 159.309 Limitations on discharge of treated sewage or graywater. (a) No person shall discharge treated sewage or graywater from a cruise vessel into the...

  7. Pulsed Gas Lasers Pumped by a Runaway Electron Initiated Discharge

    Science.gov (United States)

    Panchenko, A. N.; Tarasenko, V. F.; Panchenko, N. A.

    2017-12-01

    The generation parameters are investigated in a runaway electron preionized diffuse discharge (REP DD). Laser generation is produced in different spectral bands from the IR to VUV range. New modes of the nitrogen laser operation are obtained. Ultimate efficiencies of N2- and nonchain HF(DF)-lasers are achieved. A possibility of increasing the pulse durations of XeF-, KrF-, ArF- and VUV F2- lasers (157 nm) in an oscillating REP DD is shown. The efficiencies of VUV- and UV-generation comparable with that of a laser pumped by a self-sustained volume discharge with preionization are gained.

  8. Electrical discharge light sources: a challenge for the future

    International Nuclear Information System (INIS)

    Zissis, G.

    2001-01-01

    The first electric powder lamp operated that 150 years ago, since then the evolution of light sources is astonishing. Today, more than 10 % of the global electric power produced worldwide serve fore light production from several billions lamps. Since last three decades incandescent lamps are gradually replaced by more energy efficient discharge lamps. In parallel, new generation of light emitting diodes, producing bright colours (including white) with luminous efficacy challenging even discharge lamps, appeared in past years. The objective of this paper is to focus on the state of art in the domain of light sources and discuss the challenges for the near future. (author)

  9. Nitrogen Glow Discharge by a DC Virtual Cathode

    Science.gov (United States)

    Shager, Azza M.; Sroor, Amany T.; Tayeb, Hoda A. El; Gamal, Hoda A. El; Masoud, Mohamed M.

    2008-08-01

    A DC glow discharge operating with a virtual cathode is studied. The system consists of a solid disc cathode and mesh anode. The discharge occurs in nitrogen gas at the left-hand side of Paschen's curve. The plasma electron density in the axial direction has been found to be 0.2 · 108 cm-3 at 2 cm from the mesh. The electron temperature peak value has been found to be 3.5 eV at 6 cm from the mesh. The radial distribution of the plasma electron density and temperature are discussed. The variation of the plasma parameters are in good agreement with the experimental results.

  10. Multifunctional bulk plasma source based on discharge with electron injection.

    Science.gov (United States)

    Klimov, A S; Medovnik, A V; Tyunkov, A V; Savkin, K P; Shandrikov, M V; Vizir, A V

    2013-01-01

    A bulk plasma source, based on a high-current dc glow discharge with electron injection, is described. Electron injection and some special design features of the plasma arc emitter provide a plasma source with very long periods between maintenance down-times and a long overall lifetime. The source uses a sectioned sputter-electrode array with six individual sputter targets, each of which can be independently biased. This discharge assembly configuration provides multifunctional operation, including plasma generation from different gases (argon, nitrogen, oxygen, acetylene) and deposition of composite metal nitride and oxide coatings.

  11. Ozone kinetics in low-pressure discharges

    Science.gov (United States)

    Guerra, Vasco; Marinov, Daniil; Guaitella, Olivier; Rousseau, Antoine

    2012-10-01

    Ozone kinetics is quite well established at atmospheric pressure, due to the importance of ozone in atmospheric chemistry and to the development of industrial ozone reactors. However, as the pressure is decreased and the dominant three-body reactions lose importance, the main mechanisms involved in the creation and destruction of ozone are still surrounded by important uncertainties. In this work we develop a self-consistent model for a pulsed discharge and its afterglow operating in a Pyrex reactor with inner radius 1 cm, at pressures in the range 1-5 Torr and discharge currents of 40-120 mA. The model couples the electron Boltzmann equation with a system of equations for the time evolution of the heavy particles. The calculations are compared with time-dependent measurements of ozone and atomic oxygen. Parametric studies are performed in order to clarify the role of vibrationally excited ozone in the overall kinetics and to establish the conditions where ozone production on the surface may become important. It is shown that vibrationally excited ozone does play a significant role, by increasing the time constants of ozone formation. Moreover, an upper limit for the ozone formation at the wall in these conditions is set at 10(-4).

  12. New discharge tube with virtual cathode

    International Nuclear Information System (INIS)

    Seidelmann, L.; Aubrecht, L.

    2003-01-01

    Till this time known methods of the excitation of the discharge between electrodes are using either secondary or thermo emission of electrons by the cathode. Usually we speak about the self-maintained discharge. Lifetime of the cathode, that is shortened by the emission, limits in principle, the lifetime of the whole discharge tube. The discharge can, according to the present state of the art, be induced also by the inductive way. Arrangement for excitation of such discharge is rather expensive. The construction of the inductive excited discharge tube is considerably influenced by the necessity of the limitation of the losses in excitation magnetic circuits. Especially length of the discharge and pressure of the working gas are limited by the economic standpoints. Function of the discharge is always connected with unwanted electromagnetic radiation, whose restraint is expensive and represents limiting factor for arrangement of the discharge tube (Authors)

  13. Discharge current distribution in stratified soil under impulse discharge

    Science.gov (United States)

    Eniola Fajingbesi, Fawwaz; Shahida Midi, Nur; Elsheikh, Elsheikh M. A.; Hajar Yusoff, Siti

    2017-06-01

    The mobility of charge particles traversing a material defines its electrical properties. Soil (earth) have long been the universal grounding before and after the inception of active ground systems for electrical appliance purpose due to it semi-conductive properties. The soil can thus be modelled as a single material exhibiting semi-complex inductive-reactive impedance. Under impulse discharge such as lightning strikes to soil this property of soil could result in electric potential level fluctuation ranging from ground potential rise/fall to electromagnetic pulse coupling that could ultimately fail connected electrical appliance. In this work we have experimentally model the soil and lightning discharge using point to plane electrode setup to observe the current distribution characteristics at different soil conductivity [mS/m] range. The result presented from this research indicate above 5% shift in conductivity before and after discharge which is significant for consideration when dealing with grounding designs. The current distribution in soil have also be successfully observed and analysed from experimental result using mean current magnitude in relation to electrode distance and location, current density variation with depth all showing strong correlation with theoretical assumptions of a semi-complex impedance material.

  14. The conditions for industrial effluent discharges to the municipal sewerage system

    International Nuclear Information System (INIS)

    Loigu, E.; Laeaene, A.; Kriis, T.

    1987-01-01

    The industrial waste waters of an urban area are jointly treated with municipal sewage waters. The operation of the municipal sewage treatment plant depends substantially on the quality and quantity of industrial waste water conducted to the treatment plant for joint treatment and drainage. In order to guarantee the normal run of the plant a number of normative documents have been worked out regulating the discharge of industrial effluents to the municipal sewer network. Detailed requirements for individual industrial enterprises have been elaborated on the grounds of these documents by the local bodies of Water Supply and Sewage Management. The local requirements are coordinated with the institutions for the regulation of water utilisation and water conservation under the USSR Ministry of Land Reclamation and Water Conservation and the Ministry of Fisheries and are confirmed by local municipal authorities. Control over the implementation of obligations is exercised by Water Supply and Sewerage Management authorities. The discharges of industrial effluents to municipal sewer network have to meet both general and specific requirements

  15. HIGH PERFORMANCE STATIONARY DISCHARGES IN THE DIII-D TOKAMAK

    International Nuclear Information System (INIS)

    Luce, T.C.; Wade, M.R.; Ferron, J.R.; Politzer, P.A.; Hyatt, A.W.; Sips, A.C.C.; Murakami, M.

    2003-01-01

    Recent experiments in the DIII-D tokamak [J.L. Luxon, Nucl. Fusion 42,614 (2002)] have demonstrated high β with good confinement quality under stationary conditions. Two classes of stationary discharges are observed--low q 95 discharges with sawteeth and higher q 95 without sawteeth. The discharges are deemed stationary when the plasma conditions are maintained for times greater than the current profile relaxation time. In both cases the normalized fusion performance (β N H 89P /q 95 2 ) reaches or exceeds the value of this parameter projected for Q fus = 10 in the International Thermonuclear Experimental Reactor (ITER) design [R. Aymar, et al., Plasma Phys. Control. Fusion 44, 519 (2002)]. The presence of sawteeth reduces the maximum achievable normalized β, while confinement quality (confinement time relative to scalings) is largely independent of q 95 . Even with the reduced β limit, the normalized fusion performance maximizes at the lowest q 95 . Projections to burning plasma conditions are discussed, including the methodology of the projection and the key physics issues which still require investigation

  16. Implementation of the Preventive Radiation Protection Act; here: Regulation governing ambient radioactivity monitoring subject to the Preventive Radiation Protection Act. Pt. 1. Measuring programme for specified normal operation monitoring (routine measuring programme). BMU circular letter dated 28.07.94 -RS II 6 - 15 603/3

    International Nuclear Information System (INIS)

    1994-01-01

    The regulation addresses the competent Federal and Land authorities responsible for implementation of the Preventive Radiation Protection Act, and the competent highest Land authorities. The regulation defines the scope of obligatory measurement of ambient radioactivity during normal operation of installations and determines the measuring techniques to be applied for this purpose. The programme determines compulsory instructions to be observed in the performance of the routine measuring programme by the competent Federal and Land authorities and thus ensures nationwide application of standard procedures

  17. Corners of normal matrices

    Indian Academy of Sciences (India)

    The structure of general normal matrices is far more complicated than that of two special kinds — hermitian and unitary. There are many interesting theorems for hermitian and unitary matrices whose extensions to arbitrary normal matrices have proved to be extremely recalcitrant (see e.g., [1]). The problem whose study we ...

  18. Normalized medical information visualization.

    Science.gov (United States)

    Sánchez-de-Madariaga, Ricardo; Muñoz, Adolfo; Somolinos, Roberto; Castro, Antonio; Velázquez, Iker; Moreno, Oscar; García-Pacheco, José L; Pascual, Mario; Salvador, Carlos H

    2015-01-01

    A new mark-up programming language is introduced in order to facilitate and improve the visualization of ISO/EN 13606 dual model-based normalized medical information. This is the first time that visualization of normalized medical information is addressed and the programming language is intended to be used by medical non-IT professionals.

  19. Baby Poop: What's Normal?

    Science.gov (United States)

    ... I'm breast-feeding my newborn and her bowel movements are yellow and mushy. Is this normal for baby poop? Answers from Jay L. Hoecker, M.D. Yellow, mushy bowel movements are perfectly normal for breast-fed babies. Still, ...

  20. Feasibility of wear compensation in micro EDM milling based on discharge counting and discharge population characterization

    DEFF Research Database (Denmark)

    Bissacco, Giuliano; Hansen, Hans Nørgaard; Tristo, G.

    2011-01-01

    This paper investigates the applicability of real time wear compensation in micro EDM milling based on discharge counting and discharge population characterization. Experiments were performed involving discharge counting and tool electrode wear measurement in a wide range of process parameters...

  1. Acoustic measuring of partial discharge in power transformers

    International Nuclear Information System (INIS)

    Ramírez-Niño, J; Pascacio, A

    2009-01-01

    Power transformers' reliability can be seriously affected by partial discharges. For this reason, it is necessary to implement technical methods to identify endangered equipment before catastrophic failures occur. A well-known method that can be applied either in the laboratory or in the field is the detection and localization of partial discharges, by means of the analysis of the acoustic signals they produced. An innovative partial discharge detector was developed based on the analysis of an acoustic or electrical PD signal envelope. This paper describes the architecture of the developed acoustic detector, which is composed of a set of ultrasonic sensors, signal conditioning and control modules, a graphical interface and the required software for the location of the affected area within the transformer. The conditioning and control modules perform analog to digital conversion, arrival time measurement, communication and control operations. Finally, some power transformer diagnostic testing is presented and discussed

  2. Discharge data from 50 selected rivers for GCM validation

    International Nuclear Information System (INIS)

    Duemenil, L.; Isele, K.; Liebscher, H.J.; Schroeder, U.; Schumacher, M.; Wilke, K.

    1993-01-01

    This Technical Report refers to a joint project between GRDC Koblenz and MPI Hamburg. The Global Runoff Data Centre operates under the auspieces of WMO at the Federal Institute of Hydrology (Bundesanstalt fuer Gewaesserkunde) in Koblenz. River discharge data of the 50 largest rivers provide an independent data source for the validation of the hydrological cycle in general circulation models. This type of data is particularly valuable, because in some cases the available time series are exceptionally long. The data are presented as time series of annual average discharge (averaged over the period for which data is available, see below for caveats) and as annual cycles of monthly mean discharge averaged over the length of the time series available. (orig./KW)

  3. Fast breeder reactor primary pump discharge sphere support device

    International Nuclear Information System (INIS)

    Terny, P.; Blaix, J.C.

    1987-01-01

    In their lower part, the fast breeder reactor primary pump are connected to a sphere-shaped discharge capacity from which the diagrid feedpipes emerge. This discharge capacity is rigidly set on the strongback by means of a device that bears the forces resulting from the bottom effect. This last being generated by the pressure of the sodium discharged from primary pump. When the reactor operating conditions undergo some rapid changes combined to temperature changes, the structures differential expansions result in high stresses in the sphere support as well as in the feedpipes. This paper aims at describing a sphere support which is provided with flexibility under horizontal forces and a higher stiffness under vertical forces for a better adaptation to the various loading conditions. (orig.)

  4. Study of a rare-gas transverse fast discharge

    Science.gov (United States)

    Chubb, D. L.; Michels, C. J.

    1979-01-01

    An experimental and analytical study of a Blumlein-type transverse fast discharge operating with He and Xe are presented. An electro-optical voltage probe was used to measure the discharge voltage, and the measured voltages were in agreement with the computed voltages. The analytical model was used to predict the dependence of the discharge efficiency for producing metastables and ions on the important plasma and external circuit parameters. In He the ion efficiency is greater than the metastable efficiency, while in Xe it is the opposite; the He ion efficiencies are much larger than in Xe, while Xe metastable efficiencies are much larger than in He. These differences between Xe and He are accounted by the large dissociative recombination rate of Xe compared with He.

  5. Chylocolporrhea or chylous vaginal discharge: diagnostic conundrum with therapeutic challenge.

    Science.gov (United States)

    Joshi, Bharti; Mavuduru, R S; Mandal, A K; Bhattacharya, Anish; Lal, Anupam; Jain, Vanita

    2016-04-01

    Chylocolporrhea or chylous vaginal discharge is an extremely rare manifestation of chylous reflux syndrome. Continuous loss of chyle adversely affects quality of life and results in increased morbidity due to the chronic loss of nutrients. Diagnosis and management of this condition is very challenging. A 35-year-old multiparous lady presented with the chief complaints of excessive milky vaginal discharge for 10 years. Microscopic and biochemical analysis of vaginal discharge along with hysteroscopy confirmed diagnosis of chylocolporrhea. Lymphoscintigraphy along with magnetic resonance imaging revealed site of leakage from the right external iliac lymphatics. She was started on medium-chain triglycerides-rich diet and meticulous ligation of all visible megalymphatics with tension-free lymphovenous anastomosis was done to right external iliac vein. Chylocolporrhea can be managed successfully using operative and nonoperative modalities.

  6. Regulation, proportionality and discharges of radioactive wastes: UK perspective

    International Nuclear Information System (INIS)

    Morley, Bob; Butler, Gregg; Mc Glynn, Grace

    2008-01-01

    In recent years, the UK Government and the Regulators have made a commitment to further improve the operation of the regulatory regime and to its operating within the principles of proportionality, transparency, consistency and accountability which underpin the Government's approach to regulation in general. Particular emphasis was to be placed upon ensuring that there is greater consistency in the treatment of risk and hazard; proportionate and cost effective delivery of public, worker and environmental protection; and an open and transparently applied regulatory system. It is noteworthy that with regard to radiation protection, there are different limits for public doses and workforce doses, with the latter 15 times greater. Allowable doses for medical patients are higher still. This discrepancy raises a question in itself. This presentation focuses on the practical application of the regulatory regime with particular regard to environmental discharges and disposals. Under the Radioactive Substances Act 1993, Operators within the UK nuclear industry are required to employ Best Practicable Means (BPM) to control and minimise radioactive discharges to ensure that doses from discharges are As Low As Reasonably Achievable (ALARA). Scientific assessments to date indicate that there are no expectations of environmental harm from discharges at Sellafield (and hence likewise at other UK nuclear sites where the discharges are lower), even where those discharges have historically been up to two orders of magnitude higher than current levels. Current discharges result in doses which are a small fraction of those received by the UK population due to natural background radiation. In addition, there is no proven environmental harm from foreseeable future discharges from Sellafield or other UK nuclear sites. This is supported by independent work which illustrates that the public collective dose from Sellafield discharges is almost all delivered at risks of less that one in a

  7. Making nuclear 'normal'

    International Nuclear Information System (INIS)

    Haehlen, Peter; Elmiger, Bruno

    2000-01-01

    The mechanics of the Swiss NPPs' 'come and see' programme 1995-1999 were illustrated in our contributions to all PIME workshops since 1996. Now, after four annual 'waves', all the country has been covered by the NPPs' invitation to dialogue. This makes PIME 2000 the right time to shed some light on one particular objective of this initiative: making nuclear 'normal'. The principal aim of the 'come and see' programme, namely to give the Swiss NPPs 'a voice of their own' by the end of the nuclear moratorium 1990-2000, has clearly been attained and was commented on during earlier PIMEs. It is, however, equally important that Swiss nuclear energy not only made progress in terms of public 'presence', but also in terms of being perceived as a normal part of industry, as a normal branch of the economy. The message that Swiss nuclear energy is nothing but a normal business involving normal people, was stressed by several components of the multi-prong campaign: - The speakers in the TV ads were real - 'normal' - visitors' guides and not actors; - The testimonials in the print ads were all real NPP visitors - 'normal' people - and not models; - The mailings inviting a very large number of associations to 'come and see' activated a typical channel of 'normal' Swiss social life; - Spending money on ads (a new activity for Swiss NPPs) appears to have resulted in being perceived by the media as a normal branch of the economy. Today we feel that the 'normality' message has well been received by the media. In the controversy dealing with antinuclear arguments brought forward by environmental organisations journalists nowadays as a rule give nuclear energy a voice - a normal right to be heard. As in a 'normal' controversy, the media again actively ask themselves questions about specific antinuclear claims, much more than before 1990 when the moratorium started. The result is that in many cases such arguments are discarded by journalists, because they are, e.g., found to be

  8. Internal Electrostatic Discharge Monitor - IESDM

    Science.gov (United States)

    Kim, Wousik; Goebel, Dan M.; Jun, Insoo; Garrett, Henry B.

    2011-01-01

    A document discusses an innovation designed to effectively monitor dielectric charging in spacecraft components to measure the potential for discharge in order to prevent damage from internal electrostatic discharge (IESD). High-energy electrons penetrate the structural materials and shielding of a spacecraft and then stop inside dielectrics and keep accumulating. Those deposited charges generate an electric field. If the electric field becomes higher than the breakdown threshold (approx. =2 x 10(exp 5) V/cm), discharge occurs. This monitor measures potentials as a function of dielectric depth. Differentiation of potential with respect to the depth yields electric field. Direct measurement of the depth profile of the potential in a dielectric makes real-time electronic field evaluation possible without simulations. The IESDM has been designed to emulate a multi-layer circuit board, to insert very thin metallic layers between the dielectric layers. The conductors serve as diagnostic monitoring locations to measure the deposited electron-charge and the charge dynamics. Measurement of the time-dependent potential of the metal layers provides information on the amount of charge deposited in the dielectrics and the movement of that charge with time (dynamics).

  9. An experimental study on discharge mechanism of pulsed atmospheric pressure glow discharges

    International Nuclear Information System (INIS)

    Huang Xiaojiang; Bao Yun; Sun Liqun; Zhang Jing; Shi, J. J.

    2011-01-01

    The discharge mechanism of pulsed atmospheric pressure glow discharges excited by the unipolar positive voltage pulses between two parallel plate electrodes with or without one dielectric barrier on the ground electrode in flowing helium has been characterized by nanosecond time resolved optical and electrical measurements. The uniform glow discharges can only be achieved when the voltage pulse duration is less than 1 μs with bare electrodes. With introducing a dielectric barrier on the ground electrode, a model of electrons traveling on the background ions between two discharge events is proposed to explain the discharge mechanism and characteristics in terms of discharge ignition, discharge spatial profile and discharge current amplitude.

  10. ESTIMATION OF ROUTINE DISCHARGE OF RADIONUCLIDES ON POWER REACTOR EXPERIMENTAL RDE

    Directory of Open Access Journals (Sweden)

    P.M. Udiyani

    2017-02-01

    Full Text Available Experimental power reactor (RDE which is planned to be constructed by BATAN is a kind of High Temperature Gas Cooled Reactor (HTGR with 10 MWth power. HTGR is a helium gas-cooled reactor with TRISO-coated fuel that is able to confine fission products remained in the core. Although the fission products released into the environment are very small, in order to comply the regulations the study about environmental radiation on normal or routine operation condition need to be performed. Estimation of radiology in the environment involves the source term released into the environment under routine operation condition. The purpose of this study is to estimate the source term released into the environment based on postulation of normal or routine operations of RDE. The research approach starts with an assumption that there are defects and impurities in the TRISO fuel because of limitation during the fabrication. Mechanism of fission products release from the fuel to the environment was created based on the safety features design of RDE. Radionuclides inventories in the reactor were calculated using ORIGEN-2 whose library has been modified for HTGR type, and the assumptions of defects of the TRISO fuel and release fraction for each compartment of RDE safety system used a reference parameter. The results showed that the important source terms of RDE are group of noble gases (Kr and Xe, halogen (I, Sr, Cs, H-3, and Ag. Activities of RDE source terms for routine operations have no significant difference with the HTGR source terms with the same power. Keywords: routine discharge, radionuclide, source term, RDE, HTGR

  11. Training device for nuclear power plant operators

    International Nuclear Information System (INIS)

    Schoessow, G. J.

    1985-01-01

    A simulated nuclear energy power plant system with visible internal working components comprising a reactor adapted to contain a liquid with heating elements submerged in the liquid and capable of heating the liquid to an elevated temperature, a steam generator containing water and a heat exchanger means to receive the liquid at an elevated temperature, transform the water to steam, and return the spent liquid to the reactor; a steam turbine receiving high energy steam to drive the turbine and discharging low energy steam to a condenser where the low energy steam is condensed to water which is returned to the steam generator; an electric generator driven by the turbine; indicating means to identify the physical status of the reactor and its contents; and manual and automatic controls to selectively establish normal or abnormal operating conditions in the reactor, steam generator, pressurizer, turbine, electric generator, condenser, and pumps; and to be selectively adjusted to bring the reactor to acceptable operating condition after being placed in an abnormal operation. This device is particularly useful as an education device in demonstrating nuclear reactor operations and in training operating personnel for nuclear reactor systems and also as a device for conducting research on various safety systems to improve the safety of nuclear power plants

  12. Investigation on discharge characteristics of a coaxial dielectric barrier discharge reactor driven by AC and ns power sources

    Science.gov (United States)

    Qian, WANG; Feng, LIU; Chuanrun, MIAO; Bing, YAN; Zhi, FANG

    2018-03-01

    A coaxial dielectric barrier discharge (DBD) reactor with double layer dielectric barriers has been developed for exhaust gas treatment and excited either by AC power or nanosecond (ns) pulse to generate atmospheric pressure plasma. The comparative study on the discharge characteristics of the discharge uniformity, power deposition, energy efficiency, and operation temperature between AC and ns pulsed coaxial DBD is carried out in terms of optical and electrical characteristics and operation temperature for optimizing the coaxial DBD reactor performance. The voltages across the air gap and dielectric layer and the conduction and displacement currents are extracted from the applied voltages and measured currents of AC and ns pulsed coaxial DBDs for the calculation of the power depositions and energy efficiencies through an equivalent electrical model. The discharge uniformity and operating temperature of the coaxial DBD reactor are monitored and analyzed by optical images and infrared camera. A heat conduction model is used to calculate the temperature of the internal quartz tube. It is found that the ns pulsed coaxial DBD has a much higher instantaneous power deposition in plasma, a lower total power consumption, and a higher energy efficiency compared with that excited by AC power and is more homogeneous and stable. The temperature of the outside wall of the AC and ns pulse excited coaxial DBD reaches 158 °C and 64.3 °C after 900 s operation, respectively. The experimental results on the comparison of the discharge characteristics of coaxial DBDs excited by different powers are significant for understanding of the mechanism of DBDs, reducing energy loss, and optimizing the performance of coaxial DBD in industrial applications.

  13. The regulation of technetium-99 discharges at Sellafield

    International Nuclear Information System (INIS)

    Mayall, A.

    2002-01-01

    The reprocessing of spent Magnox fuel at BNFL Sellafield produces a liquid waste concentrate containing technetium-99 and other, more radiotoxic, radionuclides such as plutonium and americium. The concentrate is known as medium active concentrate (MAC). Prior to 1981, MAC was discharged to sea untreated after several years' storage, during which short-lived radionuclides underwent radioactive decay. In the early 1980s, discharges of MAC were suspended and it was retained in storage tanks, pending the construction of a plant to remove the radionuclides of greatest radiological concern (these did not include technetium- 99). The Enhanced Actinide Removal Plant started operation in 1994 and began to clear the backlog of stored waste MAC, as well as current arisings from Magnox reprocessing. As a consequence technetium-99 was once more discharged to sea. Subsequently, concentrations of this radionuclide in the marine environment increased. In particular, there was a significant increase in the concentration of technetium-99 in lobster in the Irish Sea. An increase in technetium-99 has also been detected at locations far distant from Sellafield, e.g. in Scandinavian coastal waters, albeit at very low concentrations. This dispersal of technetium- 99 throughout the Irish Sea and further afield has therefore caused concern, although the radiological impact is low. This paper examines the nature and source of the technetium-99 in sea discharges at Sellafield and the levels of past and current discharges as well as their impact. It goes on to describe the Environment Agency's recent proposals on the future regulation of technetium-99 discharges and how these should lead to substantial reductions in not only technetium-99 discharges, but also of other radionuclides such as caesium-137 and strontium-90. (author)

  14. State Waste Discharge Permit application, 100-N Sewage Lagoon

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect groundwater would be subject to permitting under the structure of Chapter 173--216 (or 173--218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Department of Energy, Richland Operations Office entered into Consent Order No. DE 91NM-177, (Ecology and DOE-RL 1991). This document constitutes the State Waste Discharge Permit application for the 100-N Sewage Lagoon. Since the influent to the sewer lagoon is domestic waste water, the State Waste Discharge Permit application for Public Owned Treatment Works Discharges to Land was used. Although the 100-N Sewage Lagoon is not a Public Owned Treatment Works, the Public Owned Treatment Works application is more applicable than the application for industrial waste water. The 100-N Sewage Lagoon serves the 100-N Area and other Hanford Site areas by receiving domestic waste from two sources. A network of sanitary sewer piping and lift stations transfers domestic waste water from the 100-N Area buildings directly to the 100-N Sewage Lagoon. Waste is also received by trucks that transport domestic waste pumped from on site septic tanks and holding tanks. Three ponds comprise the 100-N Sewage Lagoon treatment system. These include a lined aeration pond and stabilization pond, as well as an unlined infiltration pond. Both piped-in and trucked-in domestic waste is discharged directly into the aeration pond.

  15. State Waste Discharge Permit application, 100-N Sewage Lagoon

    International Nuclear Information System (INIS)

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect groundwater would be subject to permitting under the structure of Chapter 173--216 (or 173--218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Department of Energy, Richland Operations Office entered into Consent Order No. DE 91NM-177, (Ecology and DOE-RL 1991). This document constitutes the State Waste Discharge Permit application for the 100-N Sewage Lagoon. Since the influent to the sewer lagoon is domestic waste water, the State Waste Discharge Permit application for Public Owned Treatment Works Discharges to Land was used. Although the 100-N Sewage Lagoon is not a Public Owned Treatment Works, the Public Owned Treatment Works application is more applicable than the application for industrial waste water. The 100-N Sewage Lagoon serves the 100-N Area and other Hanford Site areas by receiving domestic waste from two sources. A network of sanitary sewer piping and lift stations transfers domestic waste water from the 100-N Area buildings directly to the 100-N Sewage Lagoon. Waste is also received by trucks that transport domestic waste pumped from on site septic tanks and holding tanks. Three ponds comprise the 100-N Sewage Lagoon treatment system. These include a lined aeration pond and stabilization pond, as well as an unlined infiltration pond. Both piped-in and trucked-in domestic waste is discharged directly into the aeration pond

  16. Monitoring of radioactive discharges from nuclear power plants

    International Nuclear Information System (INIS)

    Winkelmann, I.; Becker, D.E.; Ruehle, H.

    1994-01-01

    The system of measurement of gaseous and liquid releases from NPP's into the environment in Germany is described. The emissions are continuously monitored by the operators according to uniform regulations and reported to the authorities. The quality of the measurements is assured by officially commissioned experts in accordance with the federal rule. The operators' measurements are supplemented by remote monitoring system operated by the state authorities. The measured discharges are the basis for calculation of the radiation exposure of the public. 5 tabs., 10 refs. (orig.)

  17. High intensity Discharge lighting; Alumbrado de alta intensidad de descarga

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza E, Ernesto J. [Manufacturera de Reactores, S. A., Mexico, D. F. (Mexico)

    1993-12-31

    This paper gets into contact with some fundamentals in the operation of high discharge intensity lamps. There are useful definitions, as well as the study of the operation of high pressure sodium lamps and of metallic additives operating at less than nominal power. [Espanol] Este trabajo pone al lector en contacto con algunos fundamentos de la operacion de las lamparas de alta intensidad de descarga (HID). Se encuentra con definiciones utiles, asi como el estudio de la operacion de las lamparas de sodio en alta presion y de aditivos metalicos operando a una potencia menor que la nominal.

  18. Early hospital discharge and early puerperal complications.

    Science.gov (United States)

    Ramírez-Villalobos, Dolores; Hernández-Garduño, Adolfo; Salinas, Aarón; González, Dolores; Walker, Dilys; Rojo-Herrera, Guadalupe; Hernández-Prado, Bernardo

    2009-01-01

    To evaluate the association between time of postpartum discharge and symptoms indicative of complications during the first postpartum week. Women with vaginal delivery at a Mexico City public hospital, without complications before the hospital discharge, were interviewed seven days after delivery. Time of postpartum discharge was classified as early (25 hours). The dependent variable was defined as the occurrence and severity of puerperal complication symptoms. Out of 303 women, 208 (68%) were discharged early. However, women with early discharge and satisfactory prenatal care had lower odds of presenting symptoms in early puerperium than women without early discharge and inadequate prenatal care (OR 0.36; 95% confidence intervals = 0.17-0.76). There was no association between early discharge and symptoms of complications during the first postpartum week; the odds of complications were lower for mothers with early discharge and satisfactory prenatal care.

  19. EPA Region 1 No Discharge Zones

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset details No Discharge Zones (NDZ) for New England. Boaters may not discharge waste into these areas. Boundaries were determined mostly by Federal...

  20. Loss-of-normal-feedwater sensitivity studies for AP600 behavior characterization

    International Nuclear Information System (INIS)

    Saiu, G.

    1996-01-01

    Activity concerning the development of a RELAP5/MOD3 model to simulate the Westinghouse Electric Corporation AP600 is summarized. The aim is to gain initial insight into the capability of RELAP5 to simulate the behavior of AP600 safety features. A-loss-of-normal-feedwater event is studied. Of the transients that must be investigated, this transient has been chosen to be one of the most relevant because the response of the AP600 to a loss-of-normal-feedwater event differs significantly from that of current pressurized water reactors in the extensive use of passive safety features peculiar to the AP600. Also, strong interactions among the AP600 safety systems, which should be further analyzed to permit full optimization of the system actuation logic and operation, are shown. Finally, a loss of normal feedwater without reactor scram, performed to investigate short-term plant behavior, shows that the pressure peak is affected by critical discharge flow coefficients applied to the pressurizer safety valves, while a relatively small reduction of the pressure peak is observed when both heat exchangers of the passive heat removal system are operating as opposed to the case in which only one is available. The data used for this study are derived from the Standard Safety Analysis Report configuration of the Westinghouse AP600 as of 1992