WorldWideScience

Sample records for normal measurements satisfactory

  1. 34 CFR 668.34 - Satisfactory progress.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 3 2010-07-01 2010-07-01 false Satisfactory progress. 668.34 Section 668.34 Education..., DEPARTMENT OF EDUCATION STUDENT ASSISTANCE GENERAL PROVISIONS Student Eligibility § 668.34 Satisfactory... requirements contained in § 668.32(f), the student must be making satisfactory under the provisions of...

  2. Requirements for satisfactory flying qualities of airplanes

    Science.gov (United States)

    Gilruth, R R

    1943-01-01

    Report discusses the results of an analysis of available data to determine what measured characteristics are significant in defining satisfactory flying qualities, what characteristics are reasonable to require of an airplane, and what influence the various design features have on the observed flying qualities.

  3. What do you mean by "satisfactory"?

    Science.gov (United States)

    Crebbin, W

    2005-09-01

    One of the difficulties in designing assessment for medical trainees has been defining what is meant by "satisfactory". Whilst a list of "unsatisfactory" and "outstanding" characteristics can be identified with very little difficulty, it is the middle ground that holds the challenge. This is especially true in the non-technical areas of medical practice, which have been brought into greater prominence since the development and publication of CanMEDS 2000. As part of that process, questions about what is meant by "satisfactory", "standards" and/or benchmarks, have been brought into sharper focus. Additional questions are being asked as to whether competencies must necessarily be equated with minimum expectations or if they can be set, in conjunction with standards, to situate required "satisfactory" performance at a level significantly above a minimal level. A search of current literature on competencies and assessment was carried out. From that analysis, it became evident that a definition of "satisfactory" in assessing competence is dependent upon the identification of underlying factors, including the kind of competence, the kind of knowledge, and the level of expertise required to match the standard of assessment. The varying definitions, expectations, and levels of "satisfactory" were mapped to illustrate a way to plot the level of "satisfactory" according to the task, the experience of the trainee, and the stage of training. This map also provides a method for developing shared understandings of the targeted level within the "satisfactory zone".

  4. SatisFactory Final System Evaluation Report

    OpenAIRE

    Sunlight SA

    2018-01-01

    The present document is a deliverable of the SatisFactory project, funded by the European Commission’s Directorate-General for Research and Innovation (DG RTD), under its Horizon 2020 Research and innovation programme (H2020). The main objective of this deliverable is to report on the SatisFactory Final System Evaluation, with regards to the industrial pilots at COMAU and SUNLIGHT. The evaluation of SatisFactory platform is based on the implementation of the business scenarios where each tool...

  5. 38 CFR 21.8360 - Satisfactory conduct and cooperation.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Satisfactory conduct and... Children of Vietnam Veterans-Spina Bifida and Covered Birth Defects Satisfactory Conduct and Cooperation § 21.8360 Satisfactory conduct and cooperation. The provisions for satisfactory conduct and cooperation...

  6. Mean-field learning for satisfactory solutions

    KAUST Repository

    Tembine, Hamidou; Tempone, Raul; Vilanova, Pedro

    2013-01-01

    One of the fundamental challenges in distributed interactive systems is to design efficient, accurate, and fair solutions. In such systems, a satisfactory solution is an innovative approach that aims to provide all players with a satisfactory payoff

  7. Mean-field learning for satisfactory solutions

    KAUST Repository

    Tembine, Hamidou

    2013-12-01

    One of the fundamental challenges in distributed interactive systems is to design efficient, accurate, and fair solutions. In such systems, a satisfactory solution is an innovative approach that aims to provide all players with a satisfactory payoff anytime and anywhere. In this paper we study fully distributed learning schemes for satisfactory solutions in games with continuous action space. Considering games where the payoff function depends only on own-action and an aggregate term, we show that the complexity of learning systems can be significantly reduced, leading to the so-called mean-field learning. We provide sufficient conditions for convergence to a satisfactory solution and we give explicit convergence time bounds. Then, several acceleration techniques are used in order to improve the convergence rate. We illustrate numerically the proposed mean-field learning schemes for quality-of-service management in communication networks. © 2013 IEEE.

  8. 38 CFR 21.6362 - Satisfactory conduct and cooperation.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Satisfactory conduct and cooperation. 21.6362 Section 21.6362 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS... Pension Recipients Satisfactory Conduct and Cooperation § 21.6362 Satisfactory conduct and cooperation...

  9. 38 CFR 21.362 - Satisfactory conduct and cooperation.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Satisfactory conduct and.... Chapter 31 Conduct and Cooperation § 21.362 Satisfactory conduct and cooperation. (a) General. The... satisfactory conduct and cooperation in developing and implementing a program of rehabilitation services under...

  10. 32 CFR 101.6 - Criteria for satisfactory performance.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Criteria for satisfactory performance. 101.6..., MILITARY AND CIVILIAN PARTICIPATION IN RESERVE TRAINING PROGRAMS § 101.6 Criteria for satisfactory...) Shall require members to: (1) Meet the standards of satisfactory performance of training duty set forth...

  11. 16 CFR 1105.3 - A more satisfactory standard.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false A more satisfactory standard. 1105.3 Section 1105.3 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS... satisfactory standard. In considering whether a contribution is likely to result in a more satisfactory...

  12. The Normal Fetal Pancreas.

    Science.gov (United States)

    Kivilevitch, Zvi; Achiron, Reuven; Perlman, Sharon; Gilboa, Yinon

    2017-10-01

    The aim of the study was to assess the sonographic feasibility of measuring the fetal pancreas and its normal development throughout pregnancy. We conducted a cross-sectional prospective study between 19 and 36 weeks' gestation. The study included singleton pregnancies with normal pregnancy follow-up. The pancreas circumference was measured. The first 90 cases were tested to assess feasibility. Two hundred ninety-seven fetuses of nondiabetic mothers were recruited during a 3-year period. The overall satisfactory visualization rate was 61.6%. The intraobserver and interobserver variability had high interclass correlation coefficients of of 0.964 and 0.967, respectively. A cubic polynomial regression described best the correlation of pancreas circumference with gestational age (r = 0.744; P pancreas circumference percentiles for each week of gestation were calculated. During the study period, we detected 2 cases with overgrowth syndrome and 1 case with an annular pancreas. In this study, we assessed the feasibility of sonography for measuring the fetal pancreas and established a normal reference range for the fetal pancreas circumference throughout pregnancy. This database can be helpful when investigating fetomaternal disorders that can involve its normal development. © 2017 by the American Institute of Ultrasound in Medicine.

  13. Characteristics of Patients With Satisfactory Functional Gain Following Total Joint Arthroplasty in a Postacute Rehabilitation Setting.

    Science.gov (United States)

    Hershkovitz, Avital; Vesilkov, Marina; Beloosesky, Yichayaou; Brill, Shai

    2017-01-10

    Total joint arthroplasty (TJA) is an effective and successful treatment of osteoarthritis of the hip and knee as quantified by several measures, such as pain relief, improved walking, improved self-care, functions, and increased quality of life. Data are lacking as to the definition of a satisfactory functional gain in a postacute setting and identifying the characteristics of older patients with TJA who may achieve that gain. Our aim was to characterize patients who may achieve a satisfactory functional gain in a postacute rehabilitation setting following TJA. This was a retrospective study of 180 patients with TJA admitted during 2010-2013. The main outcome measures were the Functional Independence Measure (FIM), the Montebello Rehabilitation Factor Score (MRFS) on the motor FIM, and the Timed Get Up and Go Test. Satisfactory functional gain was defined as an mFIM MRFS score above median score. Comparisons of clinical and demographic characteristics between patients who achieved a satisfactory functional gain versus those who did not were performed by the Mann-Whitney U test and the χ test. The proportion of patients who achieved a satisfactory functional gain was similar in the total knee arthroplasty and total hip arthroplasty (THA) groups. The most significant characteristic of patients who achieved a satisfactory functional gain was their admission functional ability. Age negatively impacted the ability to achieve a satisfactory functional gain in patients with THA. Functional level on admission is the best predictive factor for a better rehabilitation outcome for patients with TJA. Age negatively affects functional gain in patients with THA.

  14. 41 CFR 102-117.110 - What is satisfactory service?

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What is satisfactory service? 102-117.110 Section 102-117.110 Public Contracts and Property Management Federal Property... satisfactory service? You should consider the following factors in assessing whether a TSP offers satisfactory...

  15. 24 CFR 203.385 - Types of satisfactory title evidence.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Types of satisfactory title... Title Waivers § 203.385 Types of satisfactory title evidence. The following types of title evidence shall be satisfactory to the Commissioner: (a) Fee or owner's title policy. A fee or owner's policy of...

  16. Measurement properties of screening and diagnostic tools for autism spectrum adults of mean normal intelligence: A systematic review.

    Science.gov (United States)

    Baghdadli, A; Russet, F; Mottron, L

    2017-07-01

    The autism spectrum (AS) is a multifaceted neurodevelopmental variant associated with lifelong challenges. Despite the relevant importance of identifying AS in adults for epidemiological, public health, and quality of life issues, the measurement properties of the tools currently used to screen and diagnose adults without intellectual disabilities (ID) have not been assessed. This systematic review addresses the accuracy, reliability, and validity of the reported AS screening and diagnostic tools used in adults without ID. Electronic databases and bibliographies were searched, and identified papers evaluated against inclusion criteria. The PRISMA statement was used for reporting the review. We evaluated the quality of the papers using the COSMIN Checklist for psychometric data, and QUADAS-2 for diagnostic data. For the COSMIN assessment, evidence was considered to be strong when several methodologically good articles, or one excellent article, reported consistent evidence for or against a measurement property. For the QUADAS ratings, evidence was considered to be "satisfactory" if at least one study was rated with a low risk of bias and low concern about applicability. We included 38 articles comprising 32 studies, five reviews, and one book chapter and assessed nine tools (three diagnostic and six screening, including eight of their short versions). Among screening tools, only AQ-50, AQ-S, and RAADS-R and RAADS-14 were found to provide satisfactory or intermediate values for their psychometric properties, supported by strong or moderate evidence. Nevertheless, risks of bias and concerns on the applicability of these tools limit the evidence on their diagnostic properties. We found that none of the gold standard diagnostic tools used for children had satisfactory measurement properties. There is limited evidence for the measurement properties of the screening and diagnostic tools used for AS adults with a mean normal range of measured intelligence. This may lessen

  17. Peripartum Cardiomyopathy Treatment with Dopamine Agonist and Subsequent Pregnancy with a Satisfactory Outcome.

    Science.gov (United States)

    Melo, Maria Adélia Medeiros E; Carvalho, Jordão Sousa; Feitosa, Francisco Edson de Lucena; Araujo Júnior, Edward; Peixoto, Alberto Borges; Costa Carvalho, Francisco Herlânio; Carvalho, Regina Coeli Marques

    2016-06-01

    Pathophysiological mechanisms of peripartum cardiomyopathy are not yet completely defined, although there is a strong association with various factors that are already known, including pre-eclampsia. Peripartum cardiomyopathy treatment follows the same recommendations as heart failure with systolic dysfunction. Clinical and experimental studies suggest that products of prolactin degradation can induce this cardiomyopathy. The pharmacological suppression of prolactin production by D2 dopamine receptor agonists bromocriptine and cabergoline has demonstrated satisfactory results in the therapeutic response to the treatment. Here we present a case of an adolescent patient in her first gestation with peripartum cardiomyopathy that evolved to the normalized left ventricular function after cabergoline administration, which was used as an adjuvant in cardiac dysfunction treatment. Subsequently, despite a short interval between pregnancies, the patient exhibited satisfactory progress throughout the entire gestation or puerperium in a new pregnancy without any cardiac alterations. Dopamine agonists that are orally used and are affordable in most tertiary centers, particularly in developing countries, should be considered when treating peripartum cardiomyopathy cases. Thieme Publicações Ltda Rio de Janeiro, Brazil.

  18. 46 CFR 177.310 - Satisfactory service as a design basis.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Satisfactory service as a design basis. 177.310 Section... (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Hull Structure § 177.310 Satisfactory service as a design basis. When scantlings for the hull, deckhouse, and frames of the vessel differ from those...

  19. Measurement of cerebral blood flow in normal subjects by phase contrast MR imaging

    International Nuclear Information System (INIS)

    Kashimada, Akio; Machida, Kikuo; Honda, Norinari; Mamiya, Toshio; Takahashi, Taku; Kamano, Tsuyoshi; Inoue, Yusuke; Osada, Hisato

    1994-01-01

    Global cerebral blood flow (CBF) was quantitatively measured with a two-dimensional phase contrast cine magnetic resonance (MR) imaging technique in 24 normal subjects (mean age, 38.6 years; range, 12-70 years). Cine transverse images of the upper cervical region (32 phases/cardiac cycle) were acquired with a 1.5 Tesla MR imaging unit. In five subjects, measurement of CBF was performed before and after intravenous administration of acetazolamide (DIAMOX, 15 mg/kg). Inter- and intra-observer variations in flow volume measurement were small (r=0.970, standard error of the estimate (SEE)=2.9 ml/min, n=8; r=0.963, SEE=4.6 ml/min, n=40, respectively). In measuring flow velocity, they were inferior to those of flow volume measurement. On a visually determined setting of region of interest (ROI), reproducibility of the measurement of flow velocity was not satisfactory in this study. Thus only the results of flow volume measurement are presented. Mean summed vertebral flow volume (171 ml/min, SD=40.6) was significantly less than mean summed internal carotid flow volume (523 ml/min, SD=111). Total blood flow volume showed a significant decline with age (r=-0.45, p<0.05). The mean proportions of carotid and vertebral flow volume to total flow volume were 75.3% and 24.7%, respectively, and showed no significant change with age. The left-to-right ratio of vertebral flow volume (1.39) was significantly higher than that of internal carotid flow volume (0.99, r=0.05). After DIAMOX i.v., the mean rate of increase in total flow volume was 157%. Mean rates of increase in carotid and vertebral flow volume were 154% and 166%, respectively, which were not significantly different. In conclusion, this method is useful for estimating carotid and vertebral flow volume. (author)

  20. Measurements of normal joint angles by goniometry in calves.

    Science.gov (United States)

    Sengöz Şirin, O; Timuçin Celik, M; Ozmen, A; Avki, S

    2014-01-01

    The aim of this study was to establish normal reference values of the forelimb and hindlimb joint angles in normal Holstein calves. Thirty clinically normal Holstein calves that were free of any detectable musculoskeletal abnormalities were included in the study. A standard transparent plastic goniometer was used to measure maximum flexion, maximum extension, and range-of-motion of the shoulder, elbow, carpal, hip, stifle, and tarsal joints. The goniometric measurements were done on awake calves that were positioned in lateral recumbency. The goniometric values were measured and recorded by two independent investigators. As a result of the study it was concluded that goniometric values obtained from awake calves in lateral recumbency were found to be highly consistent and accurate between investigators (p <0.05). The data of this study acquired objective and useful information on the normal forelimb and hindlimb joint angles in normal Holstein calves. Further studies can be done to predict detailed goniometric values from different diseases and compare them.

  1. Numerically satisfactory solutions of Kummer recurrence relations

    NARCIS (Netherlands)

    J. Segura (Javier); N.M. Temme (Nico)

    2008-01-01

    textabstractPairs of numerically satisfactory solutions as $n\\rightarrow \\infty$ for the three-term recurrence relations satisfied by the families of functions $_1\\mbox{F}_1(a+\\epsilon_1 n; b +\\epsilon_2 n;z)$, $\\epsilon_i \\in {\\mathbb Z}$, are given. It is proved that minimal solutions always

  2. Normalization of voltage-sensitive dye signal with functional activity measures.

    Directory of Open Access Journals (Sweden)

    Kentaroh Takagaki

    Full Text Available In general, signal amplitude in optical imaging is normalized using the well-established DeltaF/F method, where functional activity is divided by the total fluorescent light flux. This measure is used both directly, as a measure of population activity, and indirectly, to quantify spatial and spatiotemporal activity patterns. Despite its ubiquitous use, the stability and accuracy of this measure has not been validated for voltage-sensitive dye imaging of mammalian neocortex in vivo. In this report, we find that this normalization can introduce dynamic biases. In particular, the DeltaF/F is influenced by dye staining quality, and the ratio is also unstable over the course of experiments. As methods to record and analyze optical imaging signals become more precise, such biases can have an increasingly pernicious impact on the accuracy of findings, especially in the comparison of cytoarchitechtonic areas, in area-of-activation measurements, and in plasticity or developmental experiments. These dynamic biases of the DeltaF/F method may, to an extent, be mitigated by a novel method of normalization, DeltaF/DeltaF(epileptiform. This normalization uses as a reference the measured activity of epileptiform spikes elicited by global disinhibition with bicuculline methiodide. Since this normalization is based on a functional measure, i.e. the signal amplitude of "hypersynchronized" bursts of activity in the cortical network, it is less influenced by staining of non-functional elements. We demonstrate that such a functional measure can better represent the amplitude of population mass action, and discuss alternative functional normalizations based on the amplitude of synchronized spontaneous sleep-like activity. These findings demonstrate that the traditional DeltaF/F normalization of voltage-sensitive dye signals can introduce pernicious inaccuracies in the quantification of neural population activity. They further suggest that normalization

  3. Measurement of normal auditory ossicles by high-resolusion CT with application of normal criteria to disease cases

    International Nuclear Information System (INIS)

    Hara, Jyoko

    1988-01-01

    The purposes of this study were to define criteria for the normal position of ossicles and to apply them in patients with rhinolaryngologically or pathologically confirmed diseases. Ossicles were measured on high-resolution CT images of 300 middle ears, including 241 normal ears and 59 diseased ears, in a total of 203 subjects. Angles A, B, and C to the baseline between the most lateral margins of bilateral internal auditory canals, and distance ratio b/a were defined as measurement items. Normal angles A, B, and C and distance ratio b/a ranged from 19 deg to 59 deg, 101 deg to 145 deg, 51 deg to 89 deg, and 0.49 to 0.51, respectively. Based on these criteria, all of these items were within the normal range in 30/34 (88.2 %) ears for otitis media and mastoiditis. One or more items showed far abnormal values (standard deviation; more than 3) in 5/7 (71.4 %) ears for cholesteatoma and 4/4 (100 %) ears for external ear anomaly. These normal measurements may aid in evaluating the position of auditory ossicles especially in the case of cholesteatoma and auditory ossicle abnormality. (Namekawa, K.)

  4. Measurement of normal auditory ossicles by high-resolusion CT with application of normal criteria to disease cases

    Energy Technology Data Exchange (ETDEWEB)

    Hara, Jyoko

    1988-09-01

    The purposes of this study were to define criteria for the normal position of ossicles and to apply them in patients with rhinolaryngologically or pathologically confirmed diseases. Ossicles were measured on high-resolution CT images of 300 middle ears, including 241 normal ears and 59 diseased ears, in a total of 203 subjects. Angles A, B, and C to the baseline between the most lateral margins of bilateral internal auditory canals, and distance ratio b/a were defined as measurement items. Normal angles A, B, and C and distance ratio b/a ranged from 19 deg to 59 deg, 101 deg to 145 deg, 51 deg to 89 deg, and 0.49 to 0.51, respectively. Based on these criteria, all of these items were within the normal range in 30/34 (88.2 %) ears for otitis media and mastoiditis. One or more items showed far abnormal values (standard deviation; more than 3) in 5/7 (71.4 %) ears for cholesteatoma and 4/4 (100 %) ears for external ear anomaly. These normal measurements may aid in evaluating the position of auditory ossicles especially in the case of cholesteatoma and auditory ossicle abnormality. (Namekawa, K.).

  5. Normal anatomical measurements in cervical computerized tomography

    International Nuclear Information System (INIS)

    Zaunbauer, W.; Daepp, S.; Haertel, M.

    1985-01-01

    Radiodiagnostically relevant normal values and variations for measurements of the cervical region, the arithmetical average and the standard deviation were determined from adequate computer tomograms on 60 healthy women and men, aged 20 to 83 years. The sagittal diameter of the prevertebral soft tissue and the lumina of the upper respiratory tract were evaluated at exactly defined levels between the hyoid bone and the incisura jugularis sterni. - The thickness of the aryepiglottic folds, the maximal sagittal and transverse diameters of the thyroid gland and the calibre of the great cervical vessels were defined. - To assess information about laryngeal function in computerized tomography, measurements of distances between the cervical spine and anatomical fixed points of the larynx and hypopharynx were made as well as of the degree of vocal cord movement during normal respiration and phonation. (orig.) [de

  6. MR measurement of normal corpus callosum in children

    International Nuclear Information System (INIS)

    Kim, Hyoung Sub; Kim, Jong Chul; Kang, Yong Soo; Lee, Young Hwan; Kim, Young Wol

    1997-01-01

    To measure the mean size of the various portions of the corpus callosum in normal Korean children, using MR imaging. Our subjects were 166 children (male : female=100 : 66) aged under 15 whose findings on MR imaging and neurologic examination were normal. Using midsagittal T1-weighted imaging, we measured the length of the brain and corpus callosum, the height of the latter, and the thickness of its genu body, transitional zone and splenium. The measurements were statistically analysed according to age and sex. Brain length and the size of the various portions of the corpus callosum tended to increase relatively rapidly during the first three years of life, but the rate of growth tended to decrease according to age. The mean lenght of the brain and corpus callosum and the mean thickness of the splenium of the corpus callosum did not differ according to sex. The mean thickness of the genu, body and transitional zone of the corpus callosum was greater in males than in females. The ratio of the length of the corpus callosum to the anteroposterior diameter of the brain was significantly greater in females than in males (alpha=0.05). Using MR imaging, we measured the mean sizes of the various portions of the corpus callosum in normal children;these values may provide a useful basis for determing changes occurring in its structure

  7. Measuring Conflict in a Multi-Source Environment as a Normal Measure

    OpenAIRE

    Wei, Pan; Ball, John E.; Anderson, Derek T.; Harsh, Archit; Archibald, Christopher

    2018-01-01

    In a multi-source environment, each source has its own credibility. If there is no external knowledge about credibility then we can use the information provided by the sources to assess their credibility. In this paper, we propose a way to measure conflict in a multi-source environment as a normal measure. We examine our algorithm using three simulated examples of increasing conflict and one experimental example. The results demonstrate that the proposed measure can represent conflict in a me...

  8. Coherent normalization of finger strontium XRF measurements: feasibility and limitations

    Energy Technology Data Exchange (ETDEWEB)

    Zamburlini, M; Pejovic-Milic, A; Chettle, D R [Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, L8S 4K1 (Canada)

    2008-08-07

    A non-invasive in vivo x-ray fluorescence (XRF) method of measuring bone strontium concentrations has previously been reported as a potential diagnostic tool able to detect strontium concentration in the finger and ankle bones. The feasibility of coherent normalization for {sup 125}I-source-based finger bone strontium x-ray fluorescence (XRF) measurements is assessed here by theoretical considerations and Monte Carlo simulations. Normalization would have several advantages, among which are the correction for the signal attenuation by the overlying soft tissue, and intersubject variability in the bone size and shape. The coherent normalization of bone strontium XRF measurements presents several challenges dictated by the behaviour of the coherent cross section and mass attenuation coefficient at the energies involved. It was found that the coherent normalization alone with either 22.1 keV or 35.5 keV photons was not successful in correcting for the overlying soft tissue attenuation. However, it was found that the coherent peak at 35.5 keV was able to correct effectively for variability in the finger bone size between people. Thus, it is suggested that, if the overlying soft tissue thickness can be obtained by means of an independent measurement, the 35.5 keV peak can be used to correct for the bone size, with an overall accuracy of the normalization process of better than 10%. (note)

  9. SatisFactory Common Information Data Exchange Model

    OpenAIRE

    CERTH

    2016-01-01

    This deliverable defines the Common Information Data Exchange Model (CIDEM). The aim of CIDEM is to provide a model of information elements (e.g. concepts, even, relations, interfaces) used for information exchange between components as well as for modelling work performed by other tasks (e.g. knowledge models to support human resources optimization). The CIDEM definition is considered as a shared vocabulary that enables to address the information needs for the SatisFactory framework components.

  10. Minimum energy control and optimal-satisfactory control of Boolean control network

    International Nuclear Information System (INIS)

    Li, Fangfei; Lu, Xiwen

    2013-01-01

    In the literatures, to transfer the Boolean control network from the initial state to the desired state, the expenditure of energy has been rarely considered. Motivated by this, this Letter investigates the minimum energy control and optimal-satisfactory control of Boolean control network. Based on the semi-tensor product of matrices and Floyd's algorithm, minimum energy, constrained minimum energy and optimal-satisfactory control design for Boolean control network are given respectively. A numerical example is presented to illustrate the efficiency of the obtained results.

  11. Normalized regional brain atrophy measurements in multiple sclerosis

    International Nuclear Information System (INIS)

    Zivadinov, Robert; Locatelli, Laura; Stival, Barbara; Bratina, Alessio; Nasuelli, Davide; Zorzon, Marino; Grop, Attilio; Brnabic-Razmilic, Ozana

    2003-01-01

    There is still a controversy regarding the best regional brain atrophy measurements in multiple sclerosis (MS) studies. The aim of this study was to establish whether, in a cross-sectional study, the normalized measurements of regional brain atrophy correlate better with the MRI-defined regional brain lesions than the absolute measurements of regional brain atrophy. We assessed 45 patients with clinically definite relapsing-remitting (RR) MS (median disease duration 12 years), and measured T1-lesion load (LL) and T2-LL of frontal lobes and pons, using a reproducible semi-automated technique. The regional brain parenchymal volume (RBPV) of frontal lobes and pons was obtained by use of a computerized interactive program, which incorporates semi-automated and automated segmentation processes. A normalized measurement, the regional brain parenchymal fraction (RBPF), was calculated as the ratio of RBPV to the total volume of the parenchyma and the cerebrospinal fluid (CSF) in the frontal lobes and in the region of the pons. The total regional brain volume fraction (TRBVF) was obtained after we had corrected for the total volume of the parenchyma and the CSF in the frontal lobes and in the region of the pons for the total intracranial volume. The mean coefficient of variation (CV) for RBPF of the pons was 1% for intra-observer reproducibility and 1.4% for inter-observer reproducibility. Generally, the normalized measurements of regional brain atrophy correlated with regional brain volumes and disability better than did the absolute measurements. RBPF and TRBVF correlated with T2-LL of the pons (r=-0.37, P=0.011, and r= -0.40, P=0.0005 respectively) and with T1-LL of the pons (r=-0.27, P=0.046, and r=-0.31, P=0.04, respectively), whereas RBPV did not (r=-0.18, P = NS). T1-LL of the frontal lobes was related to RBPF (r=-0.32, P=0.033) and TRBVF (r=-0.29, P=0.05), but not to RBPV (R=-0.27, P= NS). There was only a trend of correlation between T2-LL of the frontal lobes and

  12. Measurement of Lumbosacral Angle in Normal Radiographs: A ...

    African Journals Online (AJOL)

    normal lumbar lordosis measurement, the retrospective approach is a credible alternative to the prospective ... complaints, low back pain without any radiographically demonstrable ..... effects of hamstring stretching on sagittal spinal curvatures.

  13. Reports of "satisfactory relief" by IBS patients receiving usual medical care are confounded by baseline symptom severity and do not accurately reflect symptom improvement.

    Science.gov (United States)

    Whitehead, William E; Palsson, Olafur S; Levy, Rona L; Feld, Andrew D; VonKorff, Michael; Turner, Marsha

    2006-05-01

    Treatment trials for irritable bowel syndrome (IBS) usually define a responder as a patient who reports satisfactory relief or adequate relief of symptoms at the end of the trial. However, these measures have not been adequately validated. (1) Compare a binary satisfactory relief measure to alternative ways of defining a treatment responder. (2) Determine whether baseline IBS symptom severity or psychological distress influence the sensitivity of these outcome measures. A total of 350 patients (81% females, average age 50 yr) who had a medical diagnosis of IBS and satisfied Rome II criteria, were recruited from Group Health Cooperative of Puget Sound. At baseline the Irritable Bowel Severity Scale (IBSS) was used to assess symptom severity and to classify patients as mild, moderate, or severe. Psychological distress and IBS-specific quality of life (IBS-QOL) were also assessed. After 6 months treatment with standard medical care, IBSS and IBS-QOL were reassessed, and patients were asked whether they had experienced satisfactory relief and whether they were somewhat or markedly better. Initial severity of IBS significantly affected the proportion who reported satisfactory relief (mild, 72%; moderate, 53%; severe, 44%) and the proportion who were somewhat or markedly better (mild, 62%; moderate, 44%; severe, 38%), but did not affect the proportion with a 50% reduction in symptoms (mild, 26%; moderate, 25%; severe, 23%). Although mild patients were the most likely to report satisfactory relief, they showed no average decrease in symptom severity or improvement in IBS-QOL. Conversely, severe patients, who were the least likely to report satisfactory relief, had the largest reductions in IBS symptom severity and the largest improvements in IBS-QOL. Psychological distress had no significant effect on the responder rate after adjusting for IBS symptom severity. These data from a descriptive study suggest that satisfactory relief is confounded with initial IBS symptom

  14. Not Normal: the uncertainties of scientific measurements

    Science.gov (United States)

    Bailey, David C.

    2017-01-01

    Judging the significance and reproducibility of quantitative research requires a good understanding of relevant uncertainties, but it is often unclear how well these have been evaluated and what they imply. Reported scientific uncertainties were studied by analysing 41 000 measurements of 3200 quantities from medicine, nuclear and particle physics, and interlaboratory comparisons ranging from chemistry to toxicology. Outliers are common, with 5σ disagreements up to five orders of magnitude more frequent than naively expected. Uncertainty-normalized differences between multiple measurements of the same quantity are consistent with heavy-tailed Student's t-distributions that are often almost Cauchy, far from a Gaussian Normal bell curve. Medical research uncertainties are generally as well evaluated as those in physics, but physics uncertainty improves more rapidly, making feasible simple significance criteria such as the 5σ discovery convention in particle physics. Contributions to measurement uncertainty from mistakes and unknown problems are not completely unpredictable. Such errors appear to have power-law distributions consistent with how designed complex systems fail, and how unknown systematic errors are constrained by researchers. This better understanding may help improve analysis and meta-analysis of data, and help scientists and the public have more realistic expectations of what scientific results imply.

  15. Analysis of the probability of channel satisfactory state in P2P live ...

    African Journals Online (AJOL)

    In this paper a model based on user behaviour of P2P live streaming systems was developed in order to analyse one of the key QoS parameter of such systems, i.e. the probability of channel-satisfactory state, the impact of upload bandwidths and channels' popularity on the probability of channel-satisfactory state was also ...

  16. Measurement of human normal tissue and tumour responses

    International Nuclear Information System (INIS)

    Ross, G.; Yarnold, J.R.

    1988-01-01

    The scarcity of quantitative measures of normal tissue damage and tumour response in patients undergoing radiotherapy is an obstacle to the clinical evaluation of new treatment strategies. Retrospective studies of complications in critical normal tissues taught important lessons in the past concerning the potential dangers of hypofractionation. However, it is unethical to use serious complications as planned end-points in prospective studies. This paper reviews the desirable characteristics of clinical end-points required to compare alternative treatments employing radiotherapy, with emphasis on simple scales applied by clinicians or even the patients themselves

  17. Magnetic measurements on human erythrocytes: Normal, beta thalassemia major, and sickle

    Science.gov (United States)

    Sakhnini, Lama

    2003-05-01

    In this article magnetic measurements were made on human erythrocytes at different hemoglobin states (normal and reduced hemoglobin). Different blood samples: normal, beta thalassemia major, and sickle were studied. Beta thalassemia major and sickle samples were taken from patients receiving lifelong blood transfusion treatment. All samples examined exhibited diamagnetic behavior. Beta thalassemia major and sickle samples showed higher diamagnetic susceptibilities than that for the normal, which was attributed to the increase of membrane to hemoglobin volume ratio of the abnormal cells. Magnetic measurements showed that the erythrocytes in the reduced state showed less diamagnetic response in comparison with erythrocytes in the normal state. Analysis of the paramagnetic component of magnetization curves gave an effective magnetic moment of μeff=7.6 μB per reduced hemoglobin molecule. The same procedure was applied to sickle and beta thalassemia major samples and values for μeff were found to be comparable to that of the normal erythrocytes.

  18. Levels of safety satisfactory for commercialization of the breeder

    International Nuclear Information System (INIS)

    Ferguson, R.L.

    1979-01-01

    A brief discussion is presented of the Department of Energy's LMFBR safety program and the safety levels which DOE believes would be satisfactory for the commercialization of the breeder are indicated. Some observations are offered on the Three Mile Island accident and some of its implications are discussed for the LMFBR program

  19. Is the data quality of current theatre information systems satisfactory ...

    African Journals Online (AJOL)

    2006-02-17

    Feb 17, 2006 ... information systems satisfactory to monitor individual surgeons' activity? POSTGRADUATE TRAINING. L Verity, MRCOG, Consultant. Department of Obstetrics and Gynaecology, Royal Cornwall Hospital, Truro, Cornwall, UK. D Byrne, FRCOG, Consultant. J M Jenkins, FRCOG, Consultant Senior Lecturer.

  20. 41 CFR 102-117.255 - What actions may I take if the TSP's performance is not satisfactory?

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What actions may I take if the TSP's performance is not satisfactory? 102-117.255 Section 102-117.255 Public Contracts and... may I take if the TSP's performance is not satisfactory? If the TSP's performance is not satisfactory...

  1. Optical measurement of isolated canine lung filtration coefficients at normal hematocrits.

    Science.gov (United States)

    Klaesner, J W; Pou, N A; Parker, R E; Finney, C; Roselli, R J

    1997-12-01

    In this study, lung filtration coefficient (Kfc) values were measured in eight isolated canine lung preparations at normal hematocrit values using three methods: gravimetric, blood-corrected gravimetric, and optical. The lungs were kept in zone 3 conditions and subjected to an average venous pressure increase of 10.24 +/- 0.27 (SE) cmH2O. The resulting Kfc (ml . min-1 . cmH2O-1 . 100 g dry lung wt-1) measured with the gravimetric technique was 0.420 +/- 0.017, which was statistically different from the Kfc measured by the blood-corrected gravimetric method (0.273 +/- 0.018) or the product of the reflection coefficient (sigmaf) and Kfc measured optically (0. 272 +/- 0.018). The optical method involved the use of a Cellco filter cartridge to separate red blood cells from plasma, which allowed measurement of the concentration of the tracer in plasma at normal hematocrits (34 +/- 1.5). The permeability-surface area product was measured using radioactive multiple indicator-dilution methods before, during, and after venous pressure elevations. Results showed that the surface area of the lung did not change significantly during the measurement of Kfc. These studies suggest that sigmafKfc can be measured optically at normal hematocrits, that this measurement is not influenced by blood volume changes that occur during the measurement, and that the optical sigmafKfc agrees with the Kfc obtained via the blood-corrected gravimetric method.

  2. Assessment of various hilar measurements on PA chest of Korean normal adults

    International Nuclear Information System (INIS)

    Ro, Hee Jeong; Kim, Hyun; Kang, Si Won; Park, Seog Hee; Bahk, Yong Whee

    1990-01-01

    Appreciation of the normal position of the hila is essential in screening and diagnosis of the diseases of the chest. Many authors assessed the hilar position in normal adults using PA chest roentgenograms. However there have been no previous publication regarding consolidated assessment of various measurements. The authors carried out the present study to evaluate various hilar measurements including hilar points, hilar distances, difference between both hilar heights, hilar height ratio, and the relationship between the level of the clavicle and hila on the 500 normal PA chest roentgenograms

  3. High-accuracy measurements of the normal specular reflectance

    International Nuclear Information System (INIS)

    Voarino, Philippe; Piombini, Herve; Sabary, Frederic; Marteau, Daniel; Dubard, Jimmy; Hameury, Jacques; Filtz, Jean Remy

    2008-01-01

    The French Laser Megajoule (LMJ) is designed and constructed by the French Commissariata l'Energie Atomique (CEA). Its amplifying section needs highly reflective multilayer mirrors for the flash lamps. To monitor and improve the coating process, the reflectors have to be characterized to high accuracy. The described spectrophotometer is designed to measure normal specular reflectance with high repeatability by using a small spot size of 100 μm. Results are compared with ellipsometric measurements. The instrument can also perform spatial characterization to detect coating nonuniformity

  4. Measurement of Lumbosacral Angle in Normal Radiographs: A ...

    African Journals Online (AJOL)

    hyper.lordosis; most of the data in use in medical practice are based on studies on other races. Aim: To quantify the normal LSA in our population. Subjects and Methods: LSA was measured by the Fergusonfs technique and the data analyzed with SPSS Statistics version 17.0 (Chicago IL, USA). Results: LSA varied between ...

  5. Interuncal distance measurements in normal controls and patients with dementia. MR imaging study

    International Nuclear Information System (INIS)

    Ishii, Kazunari; Kitagaki, Hajime; Sakamoto, Setsu; Yamaji, Shigeru; Kono, Michio.

    1995-01-01

    To evaluate the utility of measuring interuncal distance (IUD) as a reflection of the limbic system, we compared the IUD of 60 dementia patients with that of 10 normal controls. We also measured the width of the intracranial compartment (W1 and W2) to correct for differences in individual brain size, and calculated the ratio of IUD/W1 and IUD/W2. IUD could not separate patients with dementia from normal controls, but there were significant differences in IUD/W1 and IUD/W2 between patients with dementia and normal controls. IUD, IUD/W1 and IUD/W2 did not correlate with Mini-Mental Examination score or ADAS score in patients with dementia. We conclude that IUD measurement is not helpful in distinguishing patients with mild stage dementia from normal aged people or as a scale for dementia. However, we suggest that IUD/W1 and IUD/W2 can discriminate between cases of mild dementia and normal aged people. (author)

  6. Satisfactory visualization rates of standard cardiac views at 18 to 22 weeks' gestation using spatiotemporal image correlation.

    Science.gov (United States)

    Cohen, Leeber; Mangers, Kristie; Grobman, William A; Platt, Lawrence D

    2009-12-01

    The purpose of this study was to determine the frequency with which 3 standard screening views of the fetal heart (4-chamber, left ventricular outflow tract [LVOT], and right ventricular outflow tract [RVOT]) can be obtained satisfactorily with the spatiotemporal image correlation (STIC) technique. A prospective study of 111 patients undergoing anatomic surveys at 18 to 22 weeks was performed. Two ultrasound machines with fetal cardiac settings were used. The best volume set that could be obtained from each patient during a 45-minute examination was graded by 2 sonologists with regard to whether the 4-chamber, LVOT, and RVOT images were satisfactory for screening. All 3 views were judged satisfactory for screening in most patients: 1 sonologist graded the views as satisfactory in 70% of the patients, whereas the other found the views to be satisfactory in 83%. The position of the placenta did not alter the probability of achieving a satisfactory view, but a fetus in the spine anterior position was associated with a significantly lower probability that the views were regarded as satisfactory for screening (odds ratio, 0.28; 95% confidence interval, 0.09-0.70; P < .05). This study suggests that STIC may assist with screening for cardiac anomalies at 18 to 22 weeks' gestation.

  7. 36 CFR 51.44 - How will the Director determine if a concessioner was satisfactory for purposes of a right of...

    Science.gov (United States)

    2010-07-01

    ... determine if a concessioner was satisfactory for purposes of a right of preference? 51.44 Section 51.44... satisfactory for purposes of a right of preference? To be a satisfactory concessioner for the purposes of a... concessioner made subsequent to May 17, 2000 are less than satisfactory for any two or more years of operation...

  8. 12 CFR 225.84 - What are the consequences of failing to maintain a satisfactory or better rating under the...

    Science.gov (United States)

    2010-01-01

    ... maintain a satisfactory or better rating under the Community Reinvestment Act at all insured depository... satisfactory or better rating under the Community Reinvestment Act at all insured depository institution... depository institution controlled by the financial holding company received a rating below “satisfactory...

  9. Uncertainty evaluation in normalization of isotope delta measurement results against international reference materials.

    Science.gov (United States)

    Meija, Juris; Chartrand, Michelle M G

    2018-01-01

    Isotope delta measurements are normalized against international reference standards. Although multi-point normalization is becoming a standard practice, the existing uncertainty evaluation practices are either undocumented or are incomplete. For multi-point normalization, we present errors-in-variables regression models for explicit accounting of the measurement uncertainty of the international standards along with the uncertainty that is attributed to their assigned values. This manuscript presents framework to account for the uncertainty that arises due to a small number of replicate measurements and discusses multi-laboratory data reduction while accounting for inevitable correlations between the laboratories due to the use of identical reference materials for calibration. Both frequentist and Bayesian methods of uncertainty analysis are discussed.

  10. Satisfactory patient-based outcomes after surgical treatment for idiopathic clubfoot: includes surgeon's individualized technique.

    Science.gov (United States)

    Mahan, Susan T; Spencer, Samantha A; Kasser, James R

    2014-09-01

    Treatment of idiopathic clubfoot has shifted towards Ponseti technique, but previously surgical management was standard. Outcomes of surgery have varied, with many authors reporting discouraging results. Our purpose was to evaluate a single surgeon's series of children with idiopathic clubfoot treated with a la carte posteromedial and lateral releases using the Pediatric Outcomes Data Collection Instrument (PODCI) with a minimum of 2-year follow-up. A total of 148 patients with idiopathic clubfoot treated surgically by a single surgeon over 15 years were identified, and mailed PODCI questionnaires. Fifty percent of the patients were located and responded, resulting in 74 complete questionnaires. Median age at surgery was 10 months (range, 5.3 to 84.7 mo), male sex 53/74 (71.6%), bilateral surgery 31/74 (41.9%), and average follow-up of 9.7 years. PODCI responses were compared with previously published normal healthy controls using t test for each separate category. Included in the methods is the individual surgeon's operative technique. In PODCIs where a parent reports for their child or adolescent, there was no difference between our data and the healthy controls in any of the 5 categories. In PODCI where an adolescent self-reports, there was no difference in 4 of 5 categories; significant difference was only found between our data (mean = 95.2; SD = 7.427) and normal controls (mean = 86.3; SD = 12.5) in Happiness Scale (P = 0.0031). In this group of idiopathic clubfoot patients, treated with judicious posteromedial release by a single surgeon, primarily when surgery was treatment of choice for clubfoot, patient-based outcomes are not different from their normal healthy peers through childhood and adolescence. While Ponseti treatment has since become the treatment of choice for clubfoot, surgical treatment, in some hands, has led to satisfactory results. Level III.

  11. CT measurments of cranial growth: normal subjects

    International Nuclear Information System (INIS)

    Hahn, F.J.; Chu, W.K.; Cheung, J.Y.

    1984-01-01

    Growth patterns of the cranium measured directly as head circumference have been well documented. With the availability of computed tomography (CT) , cranial dimensions can be obtained easily. The objective of this project was to establish the mean values and their normal variance of CT cranial area of subjects at different ages. Cranial area and its long and short axes were measured on CT scans for 215 neurologic patients of a wide age range who presented no evidence of abnormal growth of head size. Growth patterns of the cranial area as well as the numeric product of it linear dimensions were determined via a curve fitting process. The patterns resemble that of the head circumference growth chart, with the most rapid growth observed in the first 12 months of age and reaching full size during adolescence

  12. Can an inadequate cervical cytology sample in ThinPrep be converted to a satisfactory sample by processing it with a SurePath preparation?

    Science.gov (United States)

    Sørbye, Sveinung Wergeland; Pedersen, Mette Kristin; Ekeberg, Bente; Williams, Merete E Johansen; Sauer, Torill; Chen, Ying

    2017-01-01

    The Norwegian Cervical Cancer Screening Program recommends screening every 3 years for women between 25 and 69 years of age. There is a large difference in the percentage of unsatisfactory samples between laboratories that use different brands of liquid-based cytology. We wished to examine if inadequate ThinPrep samples could be satisfactory by processing them with the SurePath protocol. A total of 187 inadequate ThinPrep specimens from the Department of Clinical Pathology at University Hospital of North Norway were sent to Akershus University Hospital for conversion to SurePath medium. Ninety-one (48.7%) were processed through the automated "gynecologic" application for cervix cytology samples, and 96 (51.3%) were processed with the "nongynecological" automatic program. Out of 187 samples that had been unsatisfactory by ThinPrep, 93 (49.7%) were satisfactory after being converted to SurePath. The rate of satisfactory cytology was 36.6% and 62.5% for samples run through the "gynecology" program and "nongynecology" program, respectively. Of the 93 samples that became satisfactory after conversion from ThinPrep to SurePath, 80 (86.0%) were screened as normal while 13 samples (14.0%) were given an abnormal diagnosis, which included 5 atypical squamous cells of undetermined significance, 5 low-grade squamous intraepithelial lesion, 2 atypical glandular cells not otherwise specified, and 1 atypical squamous cells cannot exclude high-grade squamous intraepithelial lesion. A total of 2.1% (4/187) of the women got a diagnosis of cervical intraepithelial neoplasia 2 or higher at a later follow-up. Converting cytology samples from ThinPrep to SurePath processing can reduce the number of unsatisfactory samples. The samples should be run through the "nongynecology" program to ensure an adequate number of cells.

  13. Does bone measurement on the radius indicate skeletal status. Concise communication

    International Nuclear Information System (INIS)

    Mazess, R.B.; Peppler, W.W.; Chesney, R.W.; Lange, T.A.; Lindgren, U.; Smith, E. Jr.

    1984-01-01

    Single-photon (I-125) absorptiometry was used to measure bone mineral content (BMC) of the distal third of the radius, and dual-photon absorptiometry (Gd-153) was used to measure total-body bone mineral (TBBM), as well as the BMC of major skeletal regions. Measurements were done in normal females, normal males, osteoporotic females, osteoporotic males, and renal patients. The BMC of the radius predicted TBBM well in normal subjects, but was less satisfactory in the patient groups. The spinal BMC was predicted with even lower accuracy from radius measurement. The error in predicting areal density (bone mass per unit projected skeletal area) of the lumbar and thoracic spine from the radius BMC divided by its width was smaller, but the regressions differed significantly among normals, osteoporotics, and renal patients. There was a preferential spinal osteopenia in the osteoporotic group and in about half of the renal patients. Bone measurements on the radius can indicate overall skeletal status in normal subjects and to a lesser degree in patients, but these radius measurements are inaccurate, even on the average, as an indicator of spinal state

  14. A study of the normal interpedicular distance of the spine in Korean teenagers (Estimation of normal range by roentgenographic measurement)

    International Nuclear Information System (INIS)

    Lee, Myung Uk

    1979-01-01

    The radiological measurement of the interpedicular disease using a routine antero-posterior view of the spine gives important clinical criteria in evaluation of the intraspinal tumor and stenosis of the spinal canal, and aids for diagnosis of the lesions. In 1934 Elsberg and Dyke reported values of interpedicular distance as determined on roentgenograms for spine of white adult, and in 1968 Song prepared normal values of interpedicular distance for Korean adult. The present investigation was undertaken to provide normal interpedicular distance of Korean teenagers. The author observed the antero-posterior films of the spine of 200 normal teenagers which were composed of 100 male and 100 female. The normal values of the interpedicular distance of Korean teenagers were obtained, as well as 90% tolerance range for clinical use. In this statistical analysis, there were noted significant differences between male and female, and each age groups. It was observed that average male measurement were consistently larger than female by about 1 mm and the growth of the spinal canal appeared to be continued.

  15. Sonographic Measurement of Normal Splenic Length in Korean Adults

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sang Bum; Cheon, Byung Kook; Kim, Jong Min; Oh, Kyung Seoung; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk [Kosin University College of Medicine, Busan (Korea, Republic of)

    1996-12-15

    To establish upper limit of normal splenic length of Korean adults on ultrasonography and to determice the degree of interobserver and intraobserver variation. Ultrasonographic scans were performed to measure the maximum length of spleen in 105 of 150 adults selected by convenience sampling. Remained 45 cases with any conditions that could alter splenic size were excluded from this study. The maximum length of spleen was measured and correlated with body surface area, patient height, weight, age and sex. In 31 of the 105 adults we evaluated the interobserver and intraobserver variations in sonographic measurements of splenic length obtained by three radiologists in blind fashion. The mean splenic length in 105 adults was 8.56cm ({+-} 0.95). The splenic length positively correlated with body surface area, patient height and weight (P <0.001), and negatively correlated with patient age (P < 0.01). Male spleen (8.87 cm {+-} 1.07) was longer than female spleen (8.35 cm {+-} 0.81) (P < 0.05). The following guidelines are proposed for the upper limit of normal splenic length at different groups of body surface area: no longer than 10 cm at 1.20{approx}1.59 m{sup 2}, 11 cm at1.60{approx}1.79 m{sup 2}, and 12 cm at 1.80{approx}1.99 m{sup 2}. The mean interobserver variation between any two radiologists ranged from 0.32 cm ({+-} 0.29) to 0.39 cm ({+-} 0.33) and interobserver variations were within 1 cm in 96%. The mean intraobserver variations were within 0.5 cm in 91%. The splenic length closely correlated with body surface area, patient height, weight and age. Particularly the upper limit of normal splenic length changed according to body surface area. Interobserver variation about 1 cm and intraobserver variation about 0.5 cm should be considered in the measurement of the splenic length on ultrasonography

  16. Trained nurses can obtain satisfactory bone marrow aspirates and trephine biopsies.

    Science.gov (United States)

    Lawson, S; Aston, S; Baker, L; Fegan, C D; Milligan, D W

    1999-01-01

    AIMS: To assess the feasibility of training nurse practitioners to perform bone marrow aspiration and trephine biopsy, and to compare the quality of these samples with those obtained by medical staff. METHODS: A retrospective audit was undertaken of nurse practitioner and medical staff performance in bone marrow procedures in a busy haematology day unit. RESULTS: Nurse practitioners fared favourably in comparison with medical staff in performing bone marrow trephine biopsies, with mean biopsy lengths of 11 mm and 10.7 mm respectively. However, only 78% of the smears obtained by the nurses were judged technically satisfactory, compared with 91% prepared by doctors. This discrepancy was thought to be due largely to the quality of slide spreading. CONCLUSIONS: With motivated staff and a structured educational and training programme it is possible for nurse practitioners to perform the techniques of bone marrow aspiration and biopsy, and obtain specimens of satisfactory quality, thus improving efficiency of the haematology day unit and increasing quality of patient care. Images PMID:10396248

  17. 41 CFR 102-117.285 - What are my choices if a TSP's performance is not satisfactory?

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What are my choices if a TSP's performance is not satisfactory? 102-117.285 Section 102-117.285 Public Contracts and Property... are my choices if a TSP's performance is not satisfactory? You may choose to place a TSP in temporary...

  18. Measurement of normal cervical spinal cord in metrizamide CT myelography

    International Nuclear Information System (INIS)

    Suzuki, Fumio; Koyama, Tsunemaro; Aii, Heihachirou

    1985-01-01

    The shape of the spinal cord is the most important factor in diagnosis of spinal disorders by metrizamide CT myelography (met. CT). Even in cases where the spinal cord looks normal in shape its size might be abnormal, for example in cases with spinal cord atrophy, syringomyelia, intramedullary tumor and several other conditions. In detecting the slightest abnormality in such cases, it is absolutely necessary to have in hand the knowledge of the nomal size of the spinal cord at each level. We measured, therefore, the sagittal and transverse diameters of the cervical spinal cord in 55 patients with no known lesions on met. CT (Fig. 1). Comparing our results with those by others, we found some differences as to the size of the spinal cord. We assume that these differences are due to the differences in resolution of the CT scanners used. The size of the spinal cord tends to measure larger with a CT scanner with high resolution than with others. Previous authors reported that the size of the spinal cord would vary by window center settings. Our experimental results indicate, however, that window center settings do not significantly affect the measurements. It is concluded that the normal values of the spinal cord dimensions at each level somewhat differ by CT equipments used. One should have normal values with one's own equipment in hand in order to take full advantage of this sophisticated diagnostic technique. (author)

  19. A normalization of the physical tests for external irradiation measuring detectors

    International Nuclear Information System (INIS)

    1977-05-01

    This report is the result of a normalization work, realized within the Radioprotection Services of the C.E.A., of the physical tests for detectors measuring external irradiation. Among the various tests mentionned are treated more in details, calibration and the establishment of the relative spectral response. As far as calibration is concerned, the normalization refers to: the reference detector, the reference radiation source, the installation and calibration procedure. As for the relative spectral response the normalization refers to: the reference detector, the radiation sources to be used. Finally, a chapter is consecrated to the high flux detectors and to those for pulsed electromagnetic radiations [fr

  20. Speech Respiratory Measures in Spastic Cerebral Palsied and Normal Children

    Directory of Open Access Journals (Sweden)

    Hashem Shemshadi

    2007-10-01

    Full Text Available Objective: Research is designed to determine speech respiratory measures in spastic cerebral palsied children versus normal ones, to be used as an applicable tool in speech therapy plans.  Materials & Methods: Via a comparative cross-sectional study (case–control, and through a directive goal oriented sampling in case and convenience approach for controls twenty spastic cerebral palsied and twenty control ones with age (5-12 years old and sex (F=20, M=20 were matched and identified. All possible inclusion and exclusion criteria were considered by thorough past medical, clinical and para clinical such as chest X-ray and Complete Blood Counts reviews to rule out any possible pulmonary and/or systemic disorders. Their speech respiratory indices were determined by Respirometer (ST 1-dysphonia, made and normalized by Glasgow University. Obtained data were analyzed by independent T test. Results: There were significant differences between cases and control groups for "mean tidal volume", "phonatory volume" and "vital capacity" at a=0/05 values and these values in patients were less (34% than normal children (P<0/001. Conclusion: Measures obtained are highly crucial for speech therapist in any speech therapy primary rehabilitative plans for spactic cerebral palsied children.

  1. 49 CFR 385.413 - What happens if a motor carrier receives a proposed safety rating that is less than Satisfactory?

    Science.gov (United States)

    2010-10-01

    ... proposed safety rating that is less than Satisfactory? 385.413 Section 385.413 Transportation Other... Satisfactory? (a) If a motor carrier does not already have a safety permit, it will not be issued a safety permit (including a temporary safety permit) unless and until a Satisfactory safety rating is issued to...

  2. Comparison of radiographic and anatomic femoral varus angle measurements in normal dogs.

    Science.gov (United States)

    Swiderski, Jennifer K; Radecki, Steven V; Park, Richard D; Palmer, Ross H

    2008-01-01

    To determine if the clinically practiced method of radiographic femoral varus angle (R-FVA) measurement is repeatable, reproducible, and accurate. Radiographic and anatomic study. ANIMALS/SAMPLE POPULATION: Normal Walker hound cadavers (n=5) and femora (n=10). Cadavers were held in dorsally-recumbent and torso-elevated positions as 3 craniocaudal radiographs were made of each femur, by each of 2 different technicians. Femora were then harvested for direct measurement of anatomic femoral varus angle (A-FVA). R-FVA was measured on each radiograph by each of 3 examiners on 3 separate occasions. Intra-observer (repeatability) and inter-observer (reproducibility) variance in R-FVA measurement and the strength of relationship between R-FVA and A-FVA (accuracy) were determined. Mean (+/-SD) A-FVA was 5.2+/-2.1 degrees (range, 2.4-8.2 degrees). Mean (+/-SD) R-FVA was 5.8+/-1.0 degrees (range, 2.7-9.6 degrees). Intra-observer variance (range: 11-16%) and inter-observer variance (16%) were acceptable. The strength of relationship between measured R-FVA and A-FVA (maximum adjusted R(2)hounds. The detected inaccuracy may be real or the result of a selection bias for normal dogs obscuring the true relationship. R-FVA may not be an accurate method of femoral varus measurement in dogs with A-FVA10 degrees), the procedure would not have been erroneously performed in any of the normal dogs of this study.

  3. MR measurement of normal brainstem cerebellum and corpus callosum on midsagittal section

    International Nuclear Information System (INIS)

    Kogame, Saeko; Sawa, S.; Inoue, Yuichi; Fukuda, Teruo; Tada, Takuji; Shakudo, Miyuki; Yahata, Kunifumi; Shimizu, Hiroshi; Onoyama, Yasuhito.

    1989-01-01

    The dimensions of the brainstem, cerebellum and corpus callosum were measured on magnetic resonance (MR) images with sagittal spin-echo sequence. Eighty-two normal adults (average 49.6 years old) were measured. The mesencephalic, pontine or cerebellar diamaters and lengths could be measured more accurately and reproducibly than medullary diameter and length. The anterio-posterior diameter of the pons and the cerebellum was 23.2±1.4 mm and 26.4±2.5 mm respectively. The length of the pons and the cerebellum was 27.8±2 mm and 45.8±3.5 mm respectively. We have observed focal thinning at the body of corpus callosum in 73%. This narrowing is almost unquestionably a normal variant. (author)

  4. Assessment of block height for satisfactory spinal anaesthesia for caesarean section.

    Science.gov (United States)

    Ousley, R; Egan, C; Dowling, K; Cyna, A M

    2012-12-01

    We investigated block heights that anaesthetists considered adequate for caesarean section to proceed under spinal anaesthesia. During 3 months, 15 obstetric anaesthetists recorded block height to touch, pinprick or cold when spinal anaesthesia was considered satisfactory for caesarean section to proceed. Median (IQR [range]) block height for touch, pinprick, first cold and icy were: T10 (T7-T12 [T3-L1]); T5 (T4-T6 [C7-L1]); T5 (T4-T6 [C7-L1]); and T3 (T2-T4 [C7-L1]), respectively. Modalities were significantly correlated for: touch and cold, p = 0.0001; touch and icy, p = 0.0007; touch and pinprick, p = 0.0018; cold and icy, p satisfactory anaesthesia despite 76 (81%) having a block to touch below T6. Single modality assessment of block height, particularly using touch, may erroneously indicate inadequate anaesthesia for caesarean section. Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.

  5. One normal void and residual following MUS surgery is all that is necessary in most patients.

    Science.gov (United States)

    Ballard, Paul; Shawer, Sami; Anderson, Colette; Khunda, Aethele

    2018-04-01

    There is considerable variation worldwide on how the assessment of voiding function is performed following midurethral sling (MUS) surgery. There is potentially a financial cost, and reduction in efficiency when patient discharge is delayed. Using our current practice of two normal void and residual (V&R) readings before discharge, the aim of this retrospective study was to evaluate the likelihood of an abnormal second V&R test if the first V&R test was normal in order to determine if a policy of discharge after only one satisfactory V&R test is reasonable. Data from 400 patients who had had MUS surgery with or without other procedures were collected. Our unit protocol included two consecutive voids of greater than 200 ml with residuals less than 150 ml before discharge. The patients were divided into the following groups: MUS only, MUS plus anterior colporrhaphy (AR) plus any other procedures (MUS/AR), and MUS with any non-AR procedures (MUS+). Complete datasets were available for 335 patients. Once inadequate tests (low volume voids <200 ml) had been excluded (28% overall), the likelihood of an abnormal second V&R test if the first test was normal was 7.1% overall, but 3.6% for MUS, 11.5% for MUS/AR and 8.6% for MUS+. The findings in the MUS-only group indicate that it is probably safe to discharge patients after one satisfactory V&R test, as long as safety measures such as 'open access' are available so that patients have unhindered readmission if problems arise.

  6. Measurement of normal ocular volume by the use of computed ...

    African Journals Online (AJOL)

    Background: Reduction or increase in ocular volume may indicate ocular pathology. Unfortunately the reference values utilized for ocular volume had been that of non-Africans. It is therefore pertinent to have a reference value of normal for Africans. Objective: To document the computer tomography (CT) scan measured ...

  7. The measurement of intrinsic cellular radiosensitivity in human tumours and normal tissues

    International Nuclear Information System (INIS)

    Lawton, P.A.

    1995-01-01

    Human tumour and normal cell radiosensitivity are thought to be important factors determining the response of tumour and normal tissues to radiotherapy, respectively. Clonogenic assays are the standard method for measuring radiosensitivity but they are of limited applicability for clinical use with fresh human tumours. The main aim of this work was to evaluate the Adhesive Tumour Cell Culture System (ATCCS), as a method for measuring the radiosensitivity of human tumours. A soft agar clonogenic assay, the modified Courtenay-Mills assay, was used as a standard to compare with the ATCCS. The demonstration that fibroblast contamination could occur with both assay methods led to the investigation of a new technique for removing unwanted fibroblasts from tumour cell suspensions and to the use of a multiwell assay for measuring fibroblast radiosensitivity. (author)

  8. The measurement of intrinsic cellular radiosensitivity in human tumours and normal tissues

    Energy Technology Data Exchange (ETDEWEB)

    Lawton, P.A.

    1995-12-31

    Human tumour and normal cell radiosensitivity are thought to be important factors determining the response of tumour and normal tissues to radiotherapy, respectively. Clonogenic assays are the standard method for measuring radiosensitivity but they are of limited applicability for clinical use with fresh human tumours. The main aim of this work was to evaluate the Adhesive Tumour Cell Culture System (ATCCS), as a method for measuring the radiosensitivity of human tumours. A soft agar clonogenic assay, the modified Courtenay-Mills assay, was used as a standard to compare with the ATCCS. The demonstration that fibroblast contamination could occur with both assay methods led to the investigation of a new technique for removing unwanted fibroblasts from tumour cell suspensions and to the use of a multiwell assay for measuring fibroblast radiosensitivity. (author).

  9. Is there a correlation between operative results and change in ventricular volume after shunt placement? A study of 60 cases of idiopathic normal-pressure hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Meier, U.; Graewe, A.; Hajdukova, A. [Department of Neurosurgery, Unfallkrankenhaus Berlin, Warener Strasse 7, 12683, Berlin (Germany); Paris, S.; Stockheim, D.; Mutze, S. [Department of Radiology, Unfallkrankenhaus Berlin, Warener Strasse 7, 12683, Berlin (Germany)

    2003-06-01

    In patients with communicating or normal-pressure hydrocephalus, ventricular volume decreases following implantation of differential pressure valves. We implanted hydrostatic (Miethke dual-switch) valves in 60 patients with normal-pressure hydrocephalus (NPH) between September 1997 and December 2001. The patients underwent CT 1 year after operation, and we measured the Evans index. Although 83% of the patients showed no change in ventricular volume as assessed by this index, 72% nevertheless showed good to excellent and 16% satisfactory clinical improvement, while 12% showed no improvement. Moderate or marked reduction in ventricular size was observed in 17%, of whom 40% of these patients showed good to excellent and 20% satisfactory clinical improvement; 40% showed unsatisfactory improvement. The favourable outcome following implantation of a hydrostatic shunt thus did not correlate with decreased ventricular volume 1 year after operation, better outcomes being observed in patients with little or no alteration in ventricular size than in those with a marked decrease. Postoperative change in ventricular volume in NPH thus does not have the same significance as in patients with high-pressure hydrocephalus. (orig.)

  10. Is there a correlation between operative results and change in ventricular volume after shunt placement? A study of 60 cases of idiopathic normal-pressure hydrocephalus

    International Nuclear Information System (INIS)

    Meier, U.; Graewe, A.; Hajdukova, A.; Paris, S.; Stockheim, D.; Mutze, S.

    2003-01-01

    In patients with communicating or normal-pressure hydrocephalus, ventricular volume decreases following implantation of differential pressure valves. We implanted hydrostatic (Miethke dual-switch) valves in 60 patients with normal-pressure hydrocephalus (NPH) between September 1997 and December 2001. The patients underwent CT 1 year after operation, and we measured the Evans index. Although 83% of the patients showed no change in ventricular volume as assessed by this index, 72% nevertheless showed good to excellent and 16% satisfactory clinical improvement, while 12% showed no improvement. Moderate or marked reduction in ventricular size was observed in 17%, of whom 40% of these patients showed good to excellent and 20% satisfactory clinical improvement; 40% showed unsatisfactory improvement. The favourable outcome following implantation of a hydrostatic shunt thus did not correlate with decreased ventricular volume 1 year after operation, better outcomes being observed in patients with little or no alteration in ventricular size than in those with a marked decrease. Postoperative change in ventricular volume in NPH thus does not have the same significance as in patients with high-pressure hydrocephalus. (orig.)

  11. Off-normal performance of EBR-II [Experimental Breeder Reactor] driver fuel

    International Nuclear Information System (INIS)

    Seidel, B.R.; Batte, G.L.; Lahm, C.E.; Fryer, R.M.; Koenig, J.F.; Hofman, G.L.

    1986-09-01

    The off-normal performance of EBR-II Mark-II driver fuel has been more than satisfactory as demonstrated by robust reliability under repeated transient overpower and undercooled loss-of-flow tests, by benign run-beyond-cladding-breach behavior, and by forgiving response to fabrication defects including lack of bond. Test results have verified that the metallic driver fuel is very tolerant of off-normal events. This behavior has allowed EBR-II to operate in a combined steady-state and transient mode to provide test capability without limitation from the metallic driver fuel

  12. 17 CFR 240.15c3-1d - Satisfactory Subordination Agreements (Appendix D to 17 CFR 240.15c3-1).

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Satisfactory Subordination...-Counter Markets § 240.15c3-1d Satisfactory Subordination Agreements (Appendix D to 17 CFR 240.15c3-1). (a) Introduction. (1) This Appendix sets forth minimum and non-exclusive requirements for satisfactory...

  13. Paediatric renal length measurements from ultrasound and DMSA scans: does clinical practice reflect theoretical normal values?

    International Nuclear Information System (INIS)

    Que, L.; Rutland, M.D.; Hassan, I.M.

    1999-01-01

    Full text: Renal length measurement is a routine part of ultrasound examination in children and those results are plotted on a normogram style graph, so that each child's results are compared to a normal range (mean ± 2 S.D.). Renal length measurements from the posterior oblique views of dimercaptosuccinic acid (DMSA) scans in our department have not always correlated well with the ultrasound measurements on the same patients. Renal lengths from the DMSA scans of 120 patients with apparently normal kidneys were recorded and used to generate a normogram of renal length at different ages (0.5-7 years). This DMSA normogram was compared to the ultrasound (US) normogram used in the Paediatric Radiology Department, and it showed slight differences in renal lengths (3-8 mm), but that the US normogram had smaller coefficients of variation (US = 6.6%, NM 8.3%), implying a 'tighter' normal range. 39 of these patients had DMSA and ultrasound measurements of renal length within 3 months, and these were studied first by calculating the mean and CV values for different age groups, and then by plotting individual renal lengths on the appropriate normograms. The measured data produced much greater variability in the ultrasound measurements than the DTPA measurements, and the individual points produced 4/78 (5.1%) abnormal results for DMSA, but 21/78 (26.9%) abnormal results for ultrasound. Thus, in routine clinical use, using patients with apparently normal kidneys, ultrasound was unable to match the 'normal range' set by their current normogram, but the nuclear medicine showed 5.1% of values outside the normal (DMSA) range, which was completely appropriate for a range of ± 2 standard deviations

  14. A feasibility study in adapting Shamos Bickel and Hodges Lehman estimator into T-Method for normalization

    Science.gov (United States)

    Harudin, N.; Jamaludin, K. R.; Muhtazaruddin, M. Nabil; Ramlie, F.; Muhamad, Wan Zuki Azman Wan

    2018-03-01

    T-Method is one of the techniques governed under Mahalanobis Taguchi System that developed specifically for multivariate data predictions. Prediction using T-Method is always possible even with very limited sample size. The user of T-Method required to clearly understanding the population data trend since this method is not considering the effect of outliers within it. Outliers may cause apparent non-normality and the entire classical methods breakdown. There exist robust parameter estimate that provide satisfactory results when the data contain outliers, as well as when the data are free of them. The robust parameter estimates of location and scale measure called Shamos Bickel (SB) and Hodges Lehman (HL) which are used as a comparable method to calculate the mean and standard deviation of classical statistic is part of it. Embedding these into T-Method normalize stage feasibly help in enhancing the accuracy of the T-Method as well as analysing the robustness of T-method itself. However, the result of higher sample size case study shows that T-method is having lowest average error percentages (3.09%) on data with extreme outliers. HL and SB is having lowest error percentages (4.67%) for data without extreme outliers with minimum error differences compared to T-Method. The error percentages prediction trend is vice versa for lower sample size case study. The result shows that with minimum sample size, which outliers always be at low risk, T-Method is much better on that, while higher sample size with extreme outliers, T-Method as well show better prediction compared to others. For the case studies conducted in this research, it shows that normalization of T-Method is showing satisfactory results and it is not feasible to adapt HL and SB or normal mean and standard deviation into it since it’s only provide minimum effect of percentages errors. Normalization using T-method is still considered having lower risk towards outlier’s effect.

  15. Spherically symmetric solution and a satisfactory energy-momentum complex

    International Nuclear Information System (INIS)

    Nashed, G.G.L.

    2005-01-01

    Mikhail et al. obtained two spherically symmetric solution in Moeller tetrad theory of gravitation. They calculated their energy content and obtained a strange value for the second solution, in spite that the associated metric of these solutions is the same (the Schwarzschild metric). We use another method given bu Gibbons and Hawking to calculate the energy content of these solutions. We also obtained a strange value of energy for the second solution. Studying the requirements of the satisfactory energy-momentum complex given by Moeller we find that the second solution which behaves as 1/√r does not transform as a four-vector under Lorentz transformation

  16. Normalization of natural gas composition data measured by gas chromatography

    International Nuclear Information System (INIS)

    Milton, Martin J T; Harris, Peter M; Brown, Andrew S; Cowper, Chris J

    2009-01-01

    The composition of natural gas determined by gas chromatography is routinely used as the basis for calculating physico-chemical properties of the gas. Since the data measured by gas chromatography have particular statistical properties, the methods used to determine the composition can make use of a priori assumptions about the statistical model for the data. We discuss a generalized approach to determining the composition, and show that there are particular statistical models for the data for which the generalized approach reduces to the widely used method of post-normalization. We also show that the post-normalization approach provides reasonable estimates of the composition for cases where it cannot be shown to arise rigorously from the statistical structure of the data

  17. Measurement of free thyroxine and free triiodothyronine concentrations by DPC RIA kits

    International Nuclear Information System (INIS)

    Kasagi, Kanji; Kousaka, Tadako; Hatabu, Hiroto; Tokuda, Yasutaka; Iida, Yasuhiro; Konishi, Junji

    1988-01-01

    'DPC RIA' kits for measuring free triiodothyronine (T3) and free thyroxine (T4) were fundamentally and clinically studied. Standard curves for incubation temperature and time were favorable. The present kits yielded satisfactory precision and reproducibility. The upper and lower limits of the normal range for T4 were 0.88 ng/dl and 2.08 ng/dl, respectively. The serum concentration of T4 was 3.91 ng/dl or more for hyperthyroidism and 0.57 ng/dl or less for hypothyroidism, allowing discrimination between the two diseases. For T3, the upper and lower limits of the normal range were 1.45 ng/dl and 3.45 ng/dl, respectively. In pregnant women and patients with decreased or increased levels of thyroxine binding globulin (TBG), the serum T3 concentration lay within the normal range. Low free T4 and T3 levels were found in 22 % and 67 %, respectively, of patients with serious non-thyroidal illness (NTI). There was a good correlation between the present kits and the other commercially available kits. Measurements of free T3 and T4 obtained by ''Amerlex RIA'' kits tended to be lower than those by the present kits in pregnant women and NTI patients with hypoalbuminemia. In view of the simplified procedure, satisfactory precision and reproducibility, and the lack of influences of serum albumin and TBG, the present kits have a potential in routine use. (Namekawa, K.)

  18. Upon delineation of normal thyroid from diffuse goiter by terminal thumb phalanx measurement and thyroid scintiscan

    International Nuclear Information System (INIS)

    Hoenle, R.

    1987-01-01

    In 265 euthyroid patients the terminal thumb phalanx was measured for estimation of a normal thyroid according to the WHO rules of a normal thyroid. The results show up that hitherto published values of a normal thyroid seem to be too high and should be re-evaluated. This is confirmed by comparison with thyroid scans of 28 patients who were normal by WHO criteria, as length and width of the thyroidal lobe as well as the calculated thyroid volume were below or in the lower range of the hitherto published data of a normal thyroid. For delineation of a normal thyroid the average size of the terminal thumb phalanx seems to be less valuable, as in one third of the cases there was no concordance with the WHO rule. The measurement of the terminal thumb phalanx by ruler as a reference value is simple and fast to be performed. (orig.) [de

  19. Normal standards for kidney length as measured with US in premature infants

    International Nuclear Information System (INIS)

    Schlesinger, A.E.; Hedlund, G.L.; Pierson, W.P.; Null, D.M.

    1986-01-01

    In order to develop normal standards for kidney length in premature infants, the authors measured kidney length by US imaging in 39 (to date) premature infants less than 72 hours old and without known renal disease. Kidney length was compared with four different parameters of body size, including gestational age, birth weight, birth length, and body surface area. Similar standards have been generated previously for normal renal length as measured by US imaging in full-term infants and older children. These standards have proven utility in cases of congenital and acquired disorders that abnormally increase or decrease renal size. Scatter plots of kidney length versus body weight and kidney length versus body surface area conformed well to a logarithmic distribution, with a high correlation coefficient and close-fitting 95% confidence limits (SEE = 2.05)

  20. ACL-RSI and KOOS Measures Predict Normal Knee Function after ACL-SPORTS Training

    OpenAIRE

    White, Kathleen; Zeni, Joseph; Snyder-Mackler, Lynn

    2014-01-01

    Objectives: After anterior cruciate ligament reconstruction (ACLR) athletes commonly report increased fear of re-injury and below normal knee function. Implementing a post-operative training protocol (ACL-SPORTS Training) to improve patient perceived knee function, may improve short term outcomes after surgery. Identifying pre-training measures that predict normal knee function after training may allow us to determine who may respond to the treatment intervention. The purpose of this study wa...

  1. Measurement and evaluation of EDM bearing currents by the normalized Joule integral

    International Nuclear Information System (INIS)

    Vidmar, Gregor; Miljavec, Damijan; Agrež, Dušan

    2014-01-01

    Apparent current density is the most common criterion used in literature to estimate bearing endangerment due to bearing currents. In the paper, a new criterion called the normalized Joule integral is proposed as a more reliable and accurate one. This approach is more general and gives good correlation between current in the bypass bridge and bearing current. Furthermore, it considers the whole current that causes bearing damage, not just its peak value. The choice of the normalized Joule integral is theoretically explained and supported by measurements and simulations. The levels of bearing endangerment related to the normalized Joule integral of bearing currents are estimated. (paper)

  2. Straatsma syndrome: Satisfactory amblyopia treatment. Report of two cases.

    Science.gov (United States)

    Quezada-Del Cid, N C; Zimmermann-Paiz, Martin A; Ordoñez-Rivas, A M; Burgos-Elías, V Y; Marroquin-Sarti, M J

    2018-06-01

    The cases are presented on 2 female patients with Straatsma syndrome, with satisfactory treatment of amblyopia. The level of anisometropia and myelination of retinal nerve fibres were different in these two patients. However, both achieved 0.20 (logMAR) visual acuity with correction in both eyes following amblyopia treatment with ocular patching. Visual prognosis of amblyopia associated with myelination of retinal nerve fibres and anisometropia is poorer than anisometropic amblyopia without myelination. It is well known that the former is refractory to occlusive therapy. Despite having a poor prognosis, visual rehabilitation should be attempted. The two cases presented were successfully treated with eye-patching. Copyright © 2018 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Measuring the electromagnetic chirality of 2D arrays under normal illumination.

    Science.gov (United States)

    Garcia-Santiago, X; Burger, S; Rockstuhl, C; Fernandez-Corbaton, I

    2017-10-15

    We present an electromagnetic chirality measure for 2D arrays of subwavelength periodicities under normal illumination. The calculation of the measure uses only the complex reflection and transmission coefficients from the array. The measure allows the ordering of arrays according to their electromagnetic chirality, which further allows a quantitative comparison of different design strategies. The measure is upper bounded, and the extreme properties of objects with high values of electromagnetic chirality make them useful in both near- and far-field applications. We analyze the consequences that different possible symmetries of the array have on its electromagnetic chirality. We use the measure to study four different arrays. The results indicate the suitability of helices for building arrays of high electromagnetic chirality, and the low effectiveness of a substrate for breaking the transverse mirror symmetry.

  4. A virtual outpatient department provides a satisfactory patient experience following endoscopy.

    Science.gov (United States)

    Ryan, Elizabeth M; Rogers, Ailín C; Hanly, Ann M; McCawley, Niamh; Deasy, Joseph; McNamara, Deborah A

    2014-03-01

    The purpose of this study was to investigate telephone follow-up of post-endoscopy patients as an alternative to attendance at the outpatient department. Access to outpatient appointments is often a target for improvement in healthcare systems. Increased outpatient clinic capacity is not feasible without investment and extra manpower in an already constrained service. Outpatient attendance was audited at a busy colorectal surgical service. A subset of patients appropriate for follow-up in a "virtual outpatient department" (VOPD) were identified. A pilot study was designed and involved telephone follow-up of low-risk endoscopic procedures. Patient satisfaction was assessed using the Medical Interview Satisfaction Scale (MISS), which is a standardised survey of patient satisfaction with healthcare experiences. This was conducted via anonymous questionnaire at the end of the study. Of a total of 166 patients undergoing endoscopy in the time period, 79 were prospectively recruited to VOPD follow-up based on eligibility criteria. Overall, 67 (84.8 %) were successfully followed up by telephone consultation; nine patients (11.4 %) were contacted by mail. The remaining three patients (3.8 %) were brought back to the OPD. Patients recruited were more likely to be younger (55.82 ± 14.96 versus 60.78 ± 13.97 years, P = 0.029) and to have had normal examinations (49.4 versus 31.0 %, χ (2) = 5.070, P = 0.025). Nearly three quarters of patients responded to the questionnaire. The mean scores for all four aspects of the MISS were satisfactory, and overall patients were satisfied with the VOPD experience. VOPD is a target for improved healthcare provision, with improved efficiency and a high patient satisfaction rate.

  5. Reference intervals of spinal mobility measures in normal individuals: the mobility study

    NARCIS (Netherlands)

    Ramiro, Sofia; van Tubergen, Astrid; Stolwijk, Carmen; van der Heijde, Desiree; Royston, Patrick; Landewe, Robert

    2015-01-01

    Objectives To establish reference intervals (RIs) for spinal mobility measures as recommended for patients with axial spondyloarthritis, and to determine the effect of age, height and gender on spinal mobility, in normal individuals. Methods A cross-sectional study (MOBILITY) was conducted among

  6. Impact of stress on the satisfactory completion of a simulated crisis scenario by reactor operator and senior reactor operator requalification trainees at the Susquehanna Training Center

    International Nuclear Information System (INIS)

    Wircenski, S.S.

    1985-01-01

    The sample of 21 requalification trainees used in this study involved four groups of trainees, who participated in the requalification training cycle from December 19, 1984, to January 16, 1985. The interference-response stress measurement was studied through the performance of tasks as measured by the instructor on the Trainee Scenario Evaluation Report. The direct-response stress measurement was examined through the measurement of heart beat and blood pressure of the trainees during the crisis scenarios as monitored by the Pollenex Digital Blood Pressure Machine. The reported-response stress measurement was studied through the trainee's self-evaluation on the Multiple Affect Adjective Check List (Anxiety Scale)-Today Form. The major findings are: (1) because of the satisfactory completion of the crisis scenario by all of the requalification trainees, the study was unable to draw a significant relationship between any single trainee characteristic and the satisfactory completion of a crisis scenario; (2) an overall pattern exists in the heart beat and blood pressure of the direct-response stress measurement and in the MAACL of the reported-response stress measurement; and (3) twelve pairs of variables compared the unusual event, the general emergency event, and following the scenario means with the baseline mean for significance. Those twelve pairs included a significant difference at the 0.05 level between six pairs

  7. analysis of the probability of channel satisfactory state in p2p live

    African Journals Online (AJOL)

    userpc

    churn and bits flow was modelled as fluid flow. The applicability of the theory of probability was deduced from Kelly (1991). Section II of the paper provides the model of. P2P live streaming systems taking into account peer behaviour and expression was obtained for the computation of the probability of channel- satisfactory ...

  8. Sonographic Measurement of Fetal Ear Length in Turkish Women with a Normal Pregnancy

    Directory of Open Access Journals (Sweden)

    Mucize Eriç Özdemir

    2014-12-01

    Full Text Available Background: Abnormal fetal ear length is a feature of chromosomal disorders. Fetal ear length measurement is a simple measurement that can be obtained during ultrasonographic examinations. Aims: To develop a nomogram for fetal ear length measurements in our population and investigate the correlation between fetal ear length, gestational age, and other standard fetal biometric measurements. Study Design: Cohort study. Methods: Ear lengths of the fetuses were measured in normal singleton pregnancies. The relationship between gestational age and fetal ear length in millimetres was analysed by simple linear regression. In addition, the correlation of fetal ear length measurements with biparietal diameter, head circumference, abdominal circumference, and femur length were evaluated.Ear length measurements were obtained from fetuses in 389 normal singleton pregnancies ranging between 16 and 28 weeks of gestation. Results: A nomogram was developed by linear regression analysis of the parameters ear length and gestational age. Fetal ear length (mm = y = (1.348 X gestational age-12.265, where gestational ages is in weeks. A high correlation was found between fetal ear length and gestational age, and a significant correlation was also found between fetal ear length and the biparietal diameter (r=0.962; p<0.001. Similar correlations were found between fetal ear length and head circumference, and fetal ear length and femur length. Conclusion: The results of this study provide a nomogram for fetal ear length. The study also demonstrates the relationship between ear length and other biometric measurements.

  9. Modified toe pulp fillet flap coverage: Better wound healing and satisfactory length preservation.

    Science.gov (United States)

    Baek, Sang Oon; Suh, Hyo Wan; Lee, Jun Yong

    2018-01-01

    Amputation is commonly performed for toe necrosis secondary to peripheral vascular diseases, such as diabetes mellitus. When amputating a necrotic toe, preservation of the bony structure is important for preventing the collapse of adjacent digits into the amputated space. However, in the popular terminal Syme's amputation technique, partial amputation of the distal phalanx could cause increased tension on the wound margin. Herein, we introduce a new way to resect sufficient bony structure while maintaining the normal length, based on a morphological analysis of the toes. Unlike the pulp of the finger in the distal phalanx, the toe has abundant teardrop-shaped pulp tissue. The ratio of the vertical length to the longitudinal length in the distal phalanx was compared between the toes and fingers. Amputation was performed at the proximal interphalangeal joint level. Then, a mobilizable pulp flap was rotated 90° cephalad to replace the distal soft tissue defect. This modified toe fillet flap was performed in 5 patients. The toe pulp was found to have a vertically oriented morphology compared to that of the fingers, enabling length preservation through cephalad rotation. All defects were successfully covered without marginal ischemia. While conventional toe fillet flap coverage focuses on the principle of length preservation as the first priority, our modified method takes both wound healing and length into account. The fattiest part of the pulp is advanced to the toe tip, providing a cushioning effect and enough length to substitute for phalangeal bone loss. Our modified method led to satisfactory functional and aesthetic outcomes.

  10. Position and width of normal adult optic chiasm as measured in coronal MRI

    International Nuclear Information System (INIS)

    Kim, Myung Soon; Park, Jin Sook

    1994-01-01

    To evaluate the position and transverse dimension of the adult optic chiasm in normal Korean adult. The authors analysed 3D coronal volume images (TR/TE=30/13, flip angle=30 .deg. ) of 136 normal adult subjects without known visual abnormality. All MRI examinations were performed using a 0.5T system. MRI was reviewed retrospectively to determine the position (horizontal and tilted) of the potic chiosm and the transverse dimension of the optic chiasm was measured. Seventy- five (55%) of the 136 normal subjects had horizontal position, and sixty-one (45%) had tilted position. Thirty- eight (62%) of 61 with tilted position showed higher position on the right side, and twenty-three (38%) showed higher position on the side. The average transverse dimension(mean SD) was 15.2 ± 0.7mm in men and 14.6 ± 1.0mm in women. The difference of transverse dimension between men and women was statistically significant. Tilted position of the adult optic chiasm on coronal MRI was seen in approximately half of normal adults. The average of transverse dimension of normal optic chiasm was 15mm

  11. TECHNIQUES FOR COMBINED PROCUREMENT OF HEARTS AND KIDNEYS WITH SATISFACTORY EARLY FUNCTION OF RENAL ALLOGRAFTS

    Science.gov (United States)

    Shaw, Byers W.; Rosenthal, J. Thomas; Griffith, Bartley F.; Haresty, Robert L.; Broznik, Brian; Hakala, Thomas; Bahnson, Henry T.; Starzl, Thomas E.

    2009-01-01

    SUMMARY Methods for combination of donor nephrectomy with donor cardiectomy are outlined. The satisfactory early function of 29 of 34 transplanted kidneys harvested with these techniques supports their wider application and should encourage their wider acceptance. PMID:6351307

  12. Shack-Hartmann centroid detection method based on high dynamic range imaging and normalization techniques

    International Nuclear Information System (INIS)

    Vargas, Javier; Gonzalez-Fernandez, Luis; Quiroga, Juan Antonio; Belenguer, Tomas

    2010-01-01

    In the optical quality measuring process of an optical system, including diamond-turning components, the use of a laser light source can produce an undesirable speckle effect in a Shack-Hartmann (SH) CCD sensor. This speckle noise can deteriorate the precision and accuracy of the wavefront sensor measurement. Here we present a SH centroid detection method founded on computer-based techniques and capable of measurement in the presence of strong speckle noise. The method extends the dynamic range imaging capabilities of the SH sensor through the use of a set of different CCD integration times. The resultant extended range spot map is normalized to accurately obtain the spot centroids. The proposed method has been applied to measure the optical quality of the main optical system (MOS) of the mid-infrared instrument telescope smulator. The wavefront at the exit of this optical system is affected by speckle noise when it is illuminated by a laser source and by air turbulence because it has a long back focal length (3017 mm). Using the proposed technique, the MOS wavefront error was measured and satisfactory results were obtained.

  13. Neutron dosimetry and spectrometry with Bonner spheres. Working out a log-normal reference matrix

    International Nuclear Information System (INIS)

    Zaborowski, Henrick.

    1981-11-01

    From the experimental and theoretical studies made upon the BONNER's spheres System with a I 6 Li(Eu) crystal and with a miniaturized 3 He counter we get the normalized energy response functions R*sub(i)(E). This normalization is obtained by the mathematization of the Resolution Function R*(i,E) in the Log-Normal distribution hypothesis to mono energetic neutrons given in April 1976 to the International Symposium on Californium 252. The fit of the Log-Normal Hypothesis with the experimental and Theoretical data is very satisfactory. The parameter's tabulated values allow a precise interpolation, at all energies between 0.4 eV and 15 MeV and for all spheres diameters between 2 and 12 inches, of the discretized R*sub(ij) Reference Matrix for the applications to neutron dosimetry and spectrometry [fr

  14. Plastic spatula with narrow long tip provides higher satisfactory smears for Pap test.

    Science.gov (United States)

    Kaur, Pervinder; Kushtagi, Pralhad

    2013-07-01

    Ayre spatula for cervical smear collection is being used despite the suggestion that different modified spatulas provide more satisfactory sampling. To see whether the cytological pickup improves with the use of long tipped spatula. Rurally based University Hospital; crossover study. Pap smear using Ayre spatula in 500 and with plastic narrow long tip (Szalay) spatula in 500 clinic attending women was taken and analyzed. Crossover smears were taken with modified spatula in 163 and using Ayre spatula in 187 women after 2 weeks of initial smears. The same pathologist made cytological reporting for all smears and was unaware of the type of spatula used. Smears from Ayre spatula had significantly higher reports of inadequate smears (94 of 500 vs. 68 of 500 for Ayre and Szalay, respectively; P = 0.032) and it remained so even after crossover (94 of 187 vs. 70 of 163 for Ayre and Szalay, respectively; P = 0.2). Cellular quality appeared better with smears taken using Szalay spatula, but the overall abnormal smear detection rate remained similar with either collection tool (χ(2) = 1.5; P = 0.2). Proportion of satisfactory smears is higher when long tip plastic spatula is used for collection of sample.

  15. Measurement of elasticity of normal placenta using the Virtual Touch quantification technique

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Size; Nan, Ruixia; Cui, Xiao Jing; Liang, Xian; Zhao, Yanan [Dept. of Ultrasound, Affiliated Hospital of Hainan Medical College, Haikou (China); Li, Yueping [Dept. of Obstetrics and Gynecology, Affiliated Hospital of Hainan Medical College, Haikou (China)

    2016-07-15

    The aim of this study was to measure the elasticity of normal placentas using the Virtual Touch quantification (VTQ) technique. This study was approved by the Institutional Ethics Committee. Fifty randomly selected, healthy pregnant women in their second trimester and 50 randomly selected, healthy pregnant women in their third trimester with a single fetus were included, and their placentas underwent VTQ through shear wave velocity (SWV) measurements. The measurements were performed at different locations to sample different areas of the placenta. Measurements were performed 3-4 times in each location, the mean shear wave velocities were calculated without the highest and lowest values of measurements in each region, and the results were compared. The SWV of the placenta was 0.983±0.260 m/sec, and the minimal and maximal speed was 0.63 m/sec and 1.84 m/sec, respectively. There was no significant difference between the second and third trimester of VTQ of the placenta in terms of SWV (0.978±0.255 m/sec vs. 0.987±0.266 m/sec, P=0.711). The maternal age between second and third trimester was 27.9±4.3 years and 29.2±4.4 years, respectively; there was no significant difference between them (P=0.159). The results of this study show that the SWV of normal placenta tissue is 0.983±0.260 m/sec, it has little variation between the second and third trimesters, and the VTQ technique may potentially play an additional role in placenta evaluation.

  16. Measurement of elasticity of normal placenta using the Virtual Touch quantification technique

    International Nuclear Information System (INIS)

    Wu, Size; Nan, Ruixia; Cui, Xiao Jing; Liang, Xian; Zhao, Yanan; Li, Yueping

    2016-01-01

    The aim of this study was to measure the elasticity of normal placentas using the Virtual Touch quantification (VTQ) technique. This study was approved by the Institutional Ethics Committee. Fifty randomly selected, healthy pregnant women in their second trimester and 50 randomly selected, healthy pregnant women in their third trimester with a single fetus were included, and their placentas underwent VTQ through shear wave velocity (SWV) measurements. The measurements were performed at different locations to sample different areas of the placenta. Measurements were performed 3-4 times in each location, the mean shear wave velocities were calculated without the highest and lowest values of measurements in each region, and the results were compared. The SWV of the placenta was 0.983±0.260 m/sec, and the minimal and maximal speed was 0.63 m/sec and 1.84 m/sec, respectively. There was no significant difference between the second and third trimester of VTQ of the placenta in terms of SWV (0.978±0.255 m/sec vs. 0.987±0.266 m/sec, P=0.711). The maternal age between second and third trimester was 27.9±4.3 years and 29.2±4.4 years, respectively; there was no significant difference between them (P=0.159). The results of this study show that the SWV of normal placenta tissue is 0.983±0.260 m/sec, it has little variation between the second and third trimesters, and the VTQ technique may potentially play an additional role in placenta evaluation

  17. Comparison of normalization methods for the analysis of metagenomic gene abundance data.

    Science.gov (United States)

    Pereira, Mariana Buongermino; Wallroth, Mikael; Jonsson, Viktor; Kristiansson, Erik

    2018-04-20

    In shotgun metagenomics, microbial communities are studied through direct sequencing of DNA without any prior cultivation. By comparing gene abundances estimated from the generated sequencing reads, functional differences between the communities can be identified. However, gene abundance data is affected by high levels of systematic variability, which can greatly reduce the statistical power and introduce false positives. Normalization, which is the process where systematic variability is identified and removed, is therefore a vital part of the data analysis. A wide range of normalization methods for high-dimensional count data has been proposed but their performance on the analysis of shotgun metagenomic data has not been evaluated. Here, we present a systematic evaluation of nine normalization methods for gene abundance data. The methods were evaluated through resampling of three comprehensive datasets, creating a realistic setting that preserved the unique characteristics of metagenomic data. Performance was measured in terms of the methods ability to identify differentially abundant genes (DAGs), correctly calculate unbiased p-values and control the false discovery rate (FDR). Our results showed that the choice of normalization method has a large impact on the end results. When the DAGs were asymmetrically present between the experimental conditions, many normalization methods had a reduced true positive rate (TPR) and a high false positive rate (FPR). The methods trimmed mean of M-values (TMM) and relative log expression (RLE) had the overall highest performance and are therefore recommended for the analysis of gene abundance data. For larger sample sizes, CSS also showed satisfactory performance. This study emphasizes the importance of selecting a suitable normalization methods in the analysis of data from shotgun metagenomics. Our results also demonstrate that improper methods may result in unacceptably high levels of false positives, which in turn may lead

  18. Measurement of urinary albumin excretion rate (AER) in normal and diabetic subjects

    International Nuclear Information System (INIS)

    Giampetro, O.; Clerico, A.; Cruschelli, L.; Miccoli, R.; Dipalma, L.; Navalesi, R.

    1987-01-01

    The chemico-clinical characteristics of two commercial RIA kits for the measurement of urinary albumin excretion in normal and diabetic subjects were compared. The chief difference between the two methods concerns the bound/free separation of the antigen, since one employs the second antybody plus PEG (Sclavo Kit), while the other uses the solid phase [antiserum bound to sepharose (Pharmacia kit)]. The two RIA methods have demonstrated a similar degree of sensitivity, feasibility and cost. The precision of the two RIAs was also similar, although the Sclavo kit has shown a better precision for lower albumin concentrations and the Pharmacia kit for higher values. In diabetic patients, elevated urinary albumin concentrations (>60 mg/L) have been found more frequently than low values (<5 mg/L); hence the Pharmacia kit seems to be preferable, because it less frequently needs dilution of urinary sample for measuring with a better precision supranormal urinary albumin values. A significant bias (about 15%) was found between the two RIAs. Bias between different albumin RIA methods could partially explain the differences of normal values previously reported in the literature

  19. Sonographic measurement of normal thyroid gland in the neonates

    International Nuclear Information System (INIS)

    Jeon, Gwun; Shin, Ji Hoon; Hong, Hyun Sook; Kim, Jung Hoon; Hwang, Jung Hwa; Goo, Dong Erk; Choi, Deuk Lin; Yang, Seung Boo

    2001-01-01

    The purpose of this study was to establish the sonographic measurement of normal thyroid gland in the neonates. Ultrasonographic evaluation of the thyroid gland was performed in the first week of life in 107 term neonates. The serum level of thyroid stimulating hormone was normal in all neonates. Their gestational age at birth was range from 37 to 41 weeks and birth weight was 3305 ± 457.74 g. Sonography was performed with 7.5 MHz linear array transducer (SA-8800 MT, Medison, Korea) within the first week of postnatal age. Maximal transverse (T), anteroposterior (AP), and longitudinal (L) dimensions of thyroid gland were measured. The volume of each lobe was estimate by using standard geometric formula; volume of a prolate ellipsoid = T X AP X L X π/6. The total volume of the thyroid gland was calculated as the sum of the each lobe. The correlations with total thyroid volume and weight, height, the body surface area, gestational age of the neonate were estimated by Pearson's coefficient and p volume on Bivariate correlation analysis. Total thyroid volume was 0.68 ± 0.23 cm 3 , left and right lobe volumes of thyroid gland were 0.32 ± 0.12 cm 3 and 0.36 ± 0.14 cm 3 , respectively. T, AP, and L dimension of right lobe were 0.69 ± 0.14 cm, 0.71 ± 0.13 cm, 1.37 ± 0.22 cm respectively. And those of left lobe were 0.70 ± 0.11 cm, 0.65 ± 0.13 cm, 1.31 ± 0.21 cm, respectively. The Pearson's coefficients for total thyroid volume with the weight, and body surface area of neonate were 0.385, 0.395 (p 3 and was significantly correlated with the weight and body surface area.

  20. Satisfactory Short-Term Results of Navigation-Assisted Gap-Balancing Total Knee Arthroplasty Using Ultracongruent Insert.

    Science.gov (United States)

    Yoon, Jung-Ro; Yang, Jae-Hyuk

    2018-03-01

    The use of highly conforming ultracongruent (UC) polyethylene insert is bone-preserving and became a relatively common alternative to the conventional posterior stabilized total knee arthroplasty (TKA) design. The purpose of this study was to analyze the short-term clinical and radiologic results of UC insert TKA using the navigation-assisted gap-balancing technique. Two hundred thirty-three knees were operated with a mean follow-up period of 8.1 years (minimum of 5 years). Radiologic and clinical outcomes were assessed before operation and at latest follow-up using the Knee Society Score and Western Ontario and McMaster Universities Osteoarthritis Index score. For statistical analysis, paired sample t-test and analysis of variance were used. Significance was considered as P satisfactory short-term outcome. Strict gap-balancing technique using the offset-type-force-controlled-spreader-system aided in the satisfactory results. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Seizure outcomes of temporal lobe epilepsy surgery in patients with normal MRI and without specific histopathology.

    Science.gov (United States)

    Ivanovic, Jugoslav; Larsson, Pål G; Østby, Ylva; Hald, John; Krossnes, Bård K; Fjeld, Jan G; Pripp, Are H; Alfstad, Kristin Å; Egge, Arild; Stanisic, Milo

    2017-05-01

    Seizure outcome following surgery in pharmacoresistant temporal lobe epilepsy patients with normal magnetic resonance imaging and normal or non-specific histopathology is not sufficiently presented in the literature. In a retrospective design, we reviewed data of 263 patients who had undergone temporal lobe epilepsy surgery and identified 26 (9.9%) who met the inclusion criteria. Seizure outcomes were determined at 2-year follow-up. Potential predictors of Engel class I (satisfactory outcome) were identified by logistic regression analyses. Engel class I outcome was achieved in 61.5% of patients, 50% being completely seizure free (Engel class IA outcome). The strongest predictors of satisfactory outcome were typical ictal seizure semiology (p = 0.048) and localised ictal discharges on scalp EEG (p = 0.036). Surgery might be an effective treatment choice for the majority of these patients, although outcomes are less favourable than in patients with magnetic resonance imaging-defined lesional temporal lobe epilepsy. Typical ictal seizure semiology and localised ictal discharges on scalp EEG were predictors of Engel class I outcome.

  2. Normal spectral emissivity measurement of molten copper using an electromagnetic levitator superimposed with a static magnetic field

    International Nuclear Information System (INIS)

    Kurosawa, Ryo; Inoue, Takamitsu; Baba, Yuya; Sugioka, Ken-ichi; Kubo, Masaki; Tsukada, Takao; Fukuyama, Hiroyuki

    2013-01-01

    The normal spectral emissivity of molten copper was determined in the wavelength range of 780–920 nm and in the temperature range of 1288–1678 K, by directly measuring the radiance emitted by an electromagnetically levitated molten copper droplet under a static magnetic field of 1.5 T. The spectrometer for radiance measurement was calibrated using the relation between the theoretical blackbody radiance from Planck's law and the light intensity of a quasi-blackbody radiation source measured using a spectrometer at a given temperature. As a result, the normal spectral emissivity of molten copper was determined as 0.075 ± 0.011 at a wavelength of 807 nm, and it was found that its temperature dependence is negligible in the entire measurement temperature range tested. In addition, the results of the normal spectral emissivity and its wavelength dependence were discussed, in comparison with those obtained using the Drude free-electron model. (paper)

  3. Different methods of measuring ADC values in normal human brain

    International Nuclear Information System (INIS)

    Wei Youping; Sheng Junkang; Zhang Caiyuan

    2009-01-01

    Objective: To investigate better method of measuring ADC values of normal brain, and provide reference for further research. Methods: Twenty healthy people's MR imaging were reviewed. All of them underwent routine MRI scans and echo-planar diffusion-weighted imaging (DWI), and ADC maps were reconstructed on work station. Six regions of interest (ROI) were selected for each object, the mean ADC values were obtained for each position on DWI and ADC maps respectively. Results: On the anisotropic DWI map calculated in the hypothalamus, ADC M , ADC P , ADC S values were no significant difference (P>0.05), in the frontal white matter and internal capsule hindlimb, there was a significant difference (P ave value exist significant difference to direct measurement on the anisotropic (isotropic) ADC map (P<0.001). Conclusion: Diffusion of water in the frontal white matter and internal capsule are anisotropic, but it is isotropic in the hypothalamus; different quantitative methods of diffusion measurement of 4ADC values have significant difference, but ADC values calculated through the DWI map is more accurate, quantitative diffusion study of brain tissue should also consider the diffusion measurement method. (authors)

  4. Measurement of elasticity of normal placenta using the Virtual Touch quantification technique

    Directory of Open Access Journals (Sweden)

    Size Wu

    2016-07-01

    Full Text Available Purpose: The aim of this study was to measure the elasticity of normal placentas using the Virtual Touch quantification (VTQ technique. Methods: This study was approved by the Institutional Ethics Committee. Fifty randomly selected, healthy pregnant women in their second trimester and 50 randomly selected, healthy pregnant women in their third trimester with a single fetus were included, and their placentas underwent VTQ through shear wave velocity (SWV measurements. The measurements were performed at different locations to sample different areas of the placenta. Measurements were performed 3-4 times in each location, the mean shear wave velocities were calculated without the highest and lowest values of measurements in each region, and the results were compared. Results: The SWV of the placenta was 0.983±0.260 m/sec, and the minimal and maximal speed was 0.63 m/sec and 1.84 m/sec, respectively. There was no significant difference between the second and third trimester of VTQ of the placenta in terms of SWV (0.978±0.255 m/sec vs. 0.987±0.266 m/sec, P=0.711. The maternal age between second and third trimester was 27.9±4.3 years and 29.2±4.4 years, respectively; there was no significant difference between them (P=0.159. Conclusion: The results of this study show that the SWV of normal placenta tissue is 0.983±0.260 m/sec, it has little variation between the second and third trimesters, and the VTQ technique may potentially play an additional role in placenta evaluation.

  5. A protocol for classifying normal- and flat-arched foot posture for research studies using clinical and radiographic measurements

    Directory of Open Access Journals (Sweden)

    Menz Hylton B

    2009-07-01

    Full Text Available Abstract Background There are several clinical and radiological methods available to classify foot posture in research, however there is no clear strategy for selecting the most appropriate measurements. Therefore, the aim of this study was to develop a foot screening protocol to distinguish between participants with normal- and flat-arched feet who would then subsequently be recruited into a series of laboratory-based gait studies. Methods The foot posture of ninety-one asymptomatic young adults was assessed using two clinical measurements (normalised navicular height and arch index and four radiological measurements taken from antero-posterior and lateral x-rays (talus-second metatarsal angle, talo-navicular coverage angle, calcaneal inclination angle and calcaneal-first metatarsal angle. Normative foot posture values were taken from the literature and used to recruit participants with normal-arched feet. Data from these participants were subsequently used to define the boundary between normal- and flat-arched feet. This information was then used to recruit participants with flat-arched feet. The relationship between the clinical and radiographic measures of foot posture was also explored. Results Thirty-two participants were recruited to the normal-arched study, 31 qualified for the flat-arched study and 28 participants were classified as having neither normal- or flat-arched feet and were not suitable for either study. The values obtained from the two clinical and four radiological measurements established two clearly defined foot posture groups. Correlations among clinical and radiological measures were significant (p r = 0.24 to 0.70. Interestingly, the clinical measures were more strongly associated with the radiographic angles obtained from the lateral view. Conclusion This foot screening protocol provides a coherent strategy for researchers planning to recruit participants with normal- and flat-arched feet. However, further research is

  6. Plastic spatula with narrow long tip provides higher satisfactory smears for Pap test

    Directory of Open Access Journals (Sweden)

    Pervinder Kaur

    2013-01-01

    Full Text Available Background: Ayre spatula for cervical smear collection is being used despite the suggestion that different modified spatulas provide more satisfactory sampling. Aims: To see whether the cytological pickup improves with the use of long tipped spatula. Setting and Design: Rurally based University Hospital; crossover study. Materials and Methods: Pap smear using Ayre spatula in 500 and with plastic narrow long tip (Szalay spatula in 500 clinic attending women was taken and analyzed. Crossover smears were taken with modified spatula in 163 and using Ayre spatula in 187 women after 2 weeks of initial smears. The same pathologist made cytological reporting for all smears and was unaware of the type of spatula used. Results: Smears from Ayre spatula had significantly higher reports of inadequate smears (94 of 500 vs. 68 of 500 for Ayre and Szalay, respectively; P = 0.032 and it remained so even after crossover (94 of 187 vs. 70 of 163 for Ayre and Szalay, respectively; P = 0.2. Cellular quality appeared better with smears taken using Szalay spatula, but the overall abnormal smear detection rate remained similar with either collection tool (χ2 = 1.5; P = 0.2. Conclusions: Proportion of satisfactory smears is higher when long tip plastic spatula is used for collection of sample.

  7. Three-dimensional sonographic measurement of normal fetal brain volume during the second half of pregnancy

    NARCIS (Netherlands)

    N.M. Roelfsema; W.C.J. Hop (Wim); S.M. Boito; J.W. Wladimiroff (Juriy)

    2004-01-01

    textabstractObjectives: This study was undertaken to develop a three-dimensional (3D) ultrasound method of measuring fetal brain volume. Study design: Serial 3D sonographic measurements of fetal brain volume were made in 68 normal singleton pregnancies at 18 to 34 weeks of gestation. A comparison

  8. Serial fetal abdominal circumference measurements in predicting normal birth weight in gestational diabetes mellitus.

    LENUS (Irish Health Repository)

    Neff, Karl J

    2013-06-24

    To construct a clinical management matrix using serial fetal abdominal circumference measurements (ACMs) that will predict normal birth weight in pregnancies complicated by gestational diabetes (GDM) and reduce unnecessary ultrasound examination in women with GDM.

  9. Normal values for bone mineral content measured by dual photon absorptiometry in children

    International Nuclear Information System (INIS)

    Tison, F.; Lecouffe, P.; Rousseau, J.; Marchandise, X.; Ythier, H.

    1990-01-01

    The results of dual photon absorptiometry measurements in 43 normal children are analyzed. Results were correlated with age, body weight, and stature. Reference stature-specific values for bone mineral content in children are proposed. Furthermore, the results show that mineralization continues beyond the end of statural growth [fr

  10. Stability measurements on cored cables in normal and superfluid helium

    International Nuclear Information System (INIS)

    GHOSH, A.K.; SAMPSON, W.B.; KIM, S.W.; LEROY, D.; OBERLI, L.R.; WILSON, M.N.

    1998-01-01

    The relative stability of LHC type cables has been measured by the direct heating of one of the individual strands with a short duration current pulse. The minimum energy required to initiate a quench has been determined for a number of cables which have a central core to increase the effective inter-strand cross-over resistance. Experiments were performed in both normal helium at 4.4 K and superfluid at 1.9 K. Conductors in general are less stable at the lower temperature when measured at the same fraction of critical current. Results show that the cored-cables, even when partially filled with solder or with a porous-metal filler exhibit a relatively low stability at currents close to the critical current. It is speculated that the high inter-strand electrical and thermal resistance inherent in these cables may effect the stability at high currents

  11. Distortion-Product Otoacoustic Emission Measured Below 300 Hz in Normal-Hearing Human Subjects

    DEFF Research Database (Denmark)

    Christensen, Anders Tornvig; Ordoñez Pizarro, Rodrigo Eduardo; Hammershøi, Dorte

    2017-01-01

    , a custom-built low-frequency acoustic probe was put to use in 21 normal-hearing human subjects (of 34 recruited). Distortion-product otoacoustic emission (DPOAE) was measured in the enclosed ear canal volume as the response to two simultaneously presented tones with frequencies f1 and f2. The stimulus...

  12. Editorial Commentary: All-Inside Anterior Cruciate Ligament Reconstruction Can Afford Satisfactory Clinical Outcome and Functional Stability.

    Science.gov (United States)

    Yoshiya, Shinichi

    2016-02-01

    Anatomic all-inside anterior cruciate ligament reconstruction using the autogenous semitendinosus tendon graft can afford satisfactory outcomes, achieving significant postoperative improvement in all clinical parameters. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  13. Dual photon absorptiometry measurement of the lumbar bone mineral content. Methodology - Reproductibility - Normal values

    International Nuclear Information System (INIS)

    Braillon, P.; Duboeuf, F.; Delmas, P.D.; Meunier, P.J.

    1987-01-01

    Measurements were made with a DPA apparatus (Novo Lab 22a) on different phantoms and on volunteers in an attempt to evaluate the system precision. The reproductibility was found in the range of 0.98 to 4.10 % in the case of in vitro measurements, depending on the geometry of the phantoms used, and in the range of 1.6 to 2.94 % for volunteers after repositioning. Secondly, the BMD in the lumbar spine of normal women and normal men was estimated. In control females, the BMD is well fitted to the age by a cubic regression. The maximum value of the BMD is found in this case at the age of 31.5 and the maximum rate of bone loss takes place at 57. Total bone loss between 31.5 and the elderly is about 32 %. In control males, results are more scattered and are represented by a simple linear regression. The average mineral loss between 30 and 80 years is 11.5 % in this area of measurement [fr

  14. Measurements of the Aerodynamic Normal Forces on a 12-kW Straight-Bladed Vertical Axis Wind Turbine

    Directory of Open Access Journals (Sweden)

    Eduard Dyachuk

    2015-08-01

    Full Text Available The knowledge of unsteady forces is necessary when designing vertical axis wind turbines (VAWTs. Measurement data for turbines operating at an open site are still very limited. The data obtained from wind tunnels or towing tanks can be used, but have limited applicability when designing large-scale VAWTs. This study presents experimental data on the normal forces of a 12-kW straight-bladed VAWT operated at an open site north of Uppsala, Sweden. The normal forces are measured with four single-axis load cells. The data are obtained for a wide range of tip speed ratios: from 1.7 to 4.6. The behavior of the normal forces is analyzed. The presented data can be used in validations of aerodynamic models and the mechanical design for VAWTs.

  15. Normal values for myocardial deformation within the right heart measured by feature-tracking cardiovascular magnetic resonance imaging.

    Science.gov (United States)

    Liu, Boyang; Dardeer, Ahmed M; Moody, William E; Edwards, Nicola C; Hudsmith, Lucy E; Steeds, Richard P

    2018-02-01

    Reproducible and repeatable assessment of right heart function is vital for monitoring congenital and acquired heart disease. There is increasing evidence for the additional value of myocardial deformation (strain and strain rate) in determining prognosis. This study aims to determine the reproducibility of deformation analyses in the right heart using cardiovascular magnetic resonance feature tracking (FT-CMR); and to establish normal ranges within an adult population. A cohort of 100 healthy subjects containing 10 males and 10 females from each decade of life between the ages of 20 and 70 without known congenital or acquired cardiovascular disease, hypertension, diabetes, dyslipidaemia or renal, hepatic, haematologic and systemic inflammatory disorders underwent FT-CMR assessment of right ventricular (RV) and right atrial (RA) myocardial strain and strain rate. RV longitudinal strain (Ell) was -21.9±3.24% (FW+S Ell) and -24.2±3.59% (FW-Ell). Peak systolic strain rate (S') was -1.45±0.39s -1 (FW+S) and -1.54±0.41s -1 (FW). Early diastolic strain rate (E') was 1.04±0.26s -1 (FW+S) and 1.04±0.33s -1 (FW). Late diastolic strain rate (A') was 0.94±0.33s -1 (FW+S) and 1.08±0.33s -1 (FW). RA peak strain was -21.1±3.76%. The intra- and inter-observer ICC for RV Ell (FW+S) was 0.92 and 0.80 respectively, while for RA peak strain was 0.92 and 0.89 respectively. Normal values of RV & RA deformation for healthy individuals using FT-CMR are provided with good RV Ell and RA peak strain reproducibility. Strain rate suffered from sub-optimal reproducibility and may not be satisfactory for clinical use. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  16. High-frequency ultrasound measurements of the normal ciliary body and iris.

    Science.gov (United States)

    Garcia, Julian P S; Spielberg, Leigh; Finger, Paul T

    2011-01-01

    To determine the normal ultrasonographic thickness of the iris and ciliary body. This prospective 35-MHz ultrasonographic study included 80 normal eyes of 40 healthy volunteers. The images were obtained at the 12-, 3-, 6-, and 9-o'clock radial meridians, measured at three locations along the radial length of the iris and at the thickest section of the ciliary body. Mixed model was used to estimate eye site-adjusted means and standard errors and to test the statistical difference of adjusted results. Parameters included mean thickness, standard deviation, and range. Mean thicknesses at the iris root, midway along the radial length of the iris, and at the juxtapupillary margin were 0.4 ± 0.1, 0.5 ± 0.1, and 0.6 ± 0.1 mm, respectively. Those of the ciliary body, ciliary processes, and ciliary body + ciliary processes were 0.7 ± 0.1, 0.6 ± 0.1, and 1.3 ± 0.2 mm, respectively. This study provides standard, normative thickness data for the iris and ciliary body in healthy adults using ultrasonographic imaging. Copyright 2011, SLACK Incorporated.

  17. A measure of uncertainty regarding the interval constraint of normal mean elicited by two stages of a prior hierarchy.

    Science.gov (United States)

    Kim, Hea-Jung

    2014-01-01

    This paper considers a hierarchical screened Gaussian model (HSGM) for Bayesian inference of normal models when an interval constraint in the mean parameter space needs to be incorporated in the modeling but when such a restriction is uncertain. An objective measure of the uncertainty, regarding the interval constraint, accounted for by using the HSGM is proposed for the Bayesian inference. For this purpose, we drive a maximum entropy prior of the normal mean, eliciting the uncertainty regarding the interval constraint, and then obtain the uncertainty measure by considering the relationship between the maximum entropy prior and the marginal prior of the normal mean in HSGM. Bayesian estimation procedure of HSGM is developed and two numerical illustrations pertaining to the properties of the uncertainty measure are provided.

  18. Which markers of subclinical organ damage to measure in individuals with high normal blood pressure?

    DEFF Research Database (Denmark)

    Sehestedt, Thomas; Jeppesen, Jørgen; Hansen, Tine W

    2009-01-01

    plaques or urine albumin/creatinine ratio of at least the 90th percentile did not produce significantly worse results. Seventy-five percent of individuals with three or more traditional risk factors had SOD. CONCLUSION: In healthy individuals with high normal BP, measuring two of pulse wave velocities......OBJECTIVE: Medical treatment of healthy individuals with high normal blood pressure (BP) is recommended if there is subclinical organ damage (SOD). We examined which markers of SOD to use based on their supplementary prognostic value. METHODS: In a population sample of 1968 individuals, aged 41, 51......, 61 and 71 years, without diabetes, prior stroke or myocardial infarction, not receiving any cardiovascular, antidiabetic or lipid-lowering medications, we measured urine albumin/creatinine ratio, carotid atherosclerotic plaques, carotid/femoral pulse wave velocity and left ventricular mass index...

  19. Retinal nerve fiber layer thickness in normals measured by spectral domain OCT.

    Science.gov (United States)

    Bendschneider, Delia; Tornow, Ralf P; Horn, Folkert K; Laemmer, Robert; Roessler, Christopher W; Juenemann, Anselm G; Kruse, Friedrich E; Mardin, Christian Y

    2010-09-01

    To determine normal values for peripapillary retinal nerve fiber layer thickness (RNFL) measured by spectral domain Optical Coherence Tomography (SOCT) in healthy white adults and to examine the relationship of RNFL with age, gender, and clinical variables. The peripapillary RNFL of 170 healthy patients (96 males and 74 females, age 20 to 78 y) was imaged with a high-resolution SOCT (Spectralis HRA+OCT, Heidelberg Engineering) in an observational cross-sectional study. RNFL thickness was measured around the optic nerve head using 16 automatically averaged, consecutive circular B-scans with 3.4-mm diameter. The automatically segmented RNFL thickness was divided into 32 segments (11.25 degrees each). One randomly selected eye per subject entered the study. Mean RNFL thickness in the study population was 97.2 ± 9.7 μm. Mean RNFL thickness was significantly negatively correlated with age (r = -0.214, P = 0.005), mean RNFL decrease per decade was 1.90 μm. As age dependency was different in different segments, age-correction of RNFL values was made for all segments separately. Age-adjusted RNFL thickness showed a significant correlation with axial length (r = -0.391, P = 0.001) and with refractive error (r = 0.396, P<0.001), but not with disc size (r = 0.124). Normal RNFL results with SOCT are comparable to those reported with time-domain OCT. In accordance with the literature on other devices, RNFL thickness measured with SOCT was significantly correlated with age and axial length. For creating a normative database of SOCT RNFL values have to be age adjusted.

  20. A Bootstrap Based Measure Robust to the Choice of Normalization Methods for Detecting Rhythmic Features in High Dimensional Data.

    Science.gov (United States)

    Larriba, Yolanda; Rueda, Cristina; Fernández, Miguel A; Peddada, Shyamal D

    2018-01-01

    Motivation: Gene-expression data obtained from high throughput technologies are subject to various sources of noise and accordingly the raw data are pre-processed before formally analyzed. Normalization of the data is a key pre-processing step, since it removes systematic variations across arrays. There are numerous normalization methods available in the literature. Based on our experience, in the context of oscillatory systems, such as cell-cycle, circadian clock, etc., the choice of the normalization method may substantially impact the determination of a gene to be rhythmic. Thus rhythmicity of a gene can purely be an artifact of how the data were normalized. Since the determination of rhythmic genes is an important component of modern toxicological and pharmacological studies, it is important to determine truly rhythmic genes that are robust to the choice of a normalization method. Results: In this paper we introduce a rhythmicity measure and a bootstrap methodology to detect rhythmic genes in an oscillatory system. Although the proposed methodology can be used for any high-throughput gene expression data, in this paper we illustrate the proposed methodology using several publicly available circadian clock microarray gene-expression datasets. We demonstrate that the choice of normalization method has very little effect on the proposed methodology. Specifically, for any pair of normalization methods considered in this paper, the resulting values of the rhythmicity measure are highly correlated. Thus it suggests that the proposed measure is robust to the choice of a normalization method. Consequently, the rhythmicity of a gene is potentially not a mere artifact of the normalization method used. Lastly, as demonstrated in the paper, the proposed bootstrap methodology can also be used for simulating data for genes participating in an oscillatory system using a reference dataset. Availability: A user friendly code implemented in R language can be downloaded from http://www.eio.uva.es/~miguel/robustdetectionprocedure.html.

  1. A Measure of Uncertainty regarding the Interval Constraint of Normal Mean Elicited by Two Stages of a Prior Hierarchy

    Directory of Open Access Journals (Sweden)

    Hea-Jung Kim

    2014-01-01

    Full Text Available This paper considers a hierarchical screened Gaussian model (HSGM for Bayesian inference of normal models when an interval constraint in the mean parameter space needs to be incorporated in the modeling but when such a restriction is uncertain. An objective measure of the uncertainty, regarding the interval constraint, accounted for by using the HSGM is proposed for the Bayesian inference. For this purpose, we drive a maximum entropy prior of the normal mean, eliciting the uncertainty regarding the interval constraint, and then obtain the uncertainty measure by considering the relationship between the maximum entropy prior and the marginal prior of the normal mean in HSGM. Bayesian estimation procedure of HSGM is developed and two numerical illustrations pertaining to the properties of the uncertainty measure are provided.

  2. A measure of the multiverse

    Energy Technology Data Exchange (ETDEWEB)

    Vilenkin, Alexander [Department of Physics and Astronomy, Institute of Cosmology, Tufts University, Medford, MA 02155 (United States)

    2007-06-22

    I review recent progress in defining a probability measure in the inflationary multiverse. General requirements for a satisfactory measure are formulated and recent proposals for the measure are clarified and discussed.

  3. A measure of the multiverse

    International Nuclear Information System (INIS)

    Vilenkin, Alexander

    2007-01-01

    I review recent progress in defining a probability measure in the inflationary multiverse. General requirements for a satisfactory measure are formulated and recent proposals for the measure are clarified and discussed

  4. Day case shoulder surgery: satisfactory pain control without regional anaesthesia. A prospective analysis of a perioperative protocol.

    LENUS (Irish Health Repository)

    Daruwalla, Z J

    2009-03-01

    Pain control is an issue which may limit patients\\' acceptance of day case shoulder surgery. This study prospectively examined the outcome of a protocol for day case shoulder surgery to determine if satisfactory pain relief could be achieved without regional anaesthesia.

  5. Gonadotropin-releasing hormone radioimmunoassay and its measurement in normal human plasma, secondary amenorrhea, and postmenopausal syndrome

    International Nuclear Information System (INIS)

    Rosenblum, N.G.; Schlaff, S.

    1976-01-01

    A sensitive and specific double antibody radioimmunoassay for gonadotropin-releasing hormone (GnRH) has been developed for measurement in ethanol extracts of human plasma. Iodinated hormone was prepared with the use of the chloramine-T method, and antibodies were developed in rabbits over a six-month period with a GnRH synthetic copolymer immunogen. A Scatchard plot revealed at least three species of antibody. The assay can measure conservatively at the 5 pg. per milliliter level and shows no cross-reactivity with other available hypothalamic and pituitary hormones. The releasing hormone was quantitatively recovered from human plasma with immunologic identity to native hormone. Unextracted plasma could not be used because of nonspecific displacement. The measurement of GnRH in individuals receiving 100 μg of intravenous bolus infusions of the synthetic decapeptide show extremely elevated values with two half-lives: one of two to four minutes and another of 35 to 40 minutes. In our experiments, we have found measurable GnRH in patients with secondary amenorrhea and at the midcycle in normal women. In the normal cycling woman during the follicular and luteal phases, GnRH was undetectable. In postmenopausal women with extreme hypoestrogenism and markedly elevated luteinizing hormone values, GnRH was also undetectable. No bursts of GnRH could be detected in normal men when sampled every ten minutes over a two-hour period and every two hours throughout the day

  6. A 3% Measurement of the Beam Normal Single Spin Asymmetry in Forward Angle Elastic Electron-Proton Scattering using the Qweak Setup

    Energy Technology Data Exchange (ETDEWEB)

    Waidyawansa, Dinayadura Buddhini [Ohio Univ., Athens, OH (United States)

    2013-08-01

    The beam normal single spin asymmetry generated in the scattering of transversely polarized electrons from unpolarized nucleons is an observable of the imaginary part of the two-photon exchange process. Moreover, it is a potential source of false asymmetry in parity violating electron scattering experiments. The Q{sub weak} experiment uses parity violating electron scattering to make a direct measurement of the weak charge of the proton. The targeted 4% measurement of the weak charge of the proton probes for parity violating new physics beyond the Standard Model. The beam normal single spin asymmetry at Q{sub weak} kinematics is at least three orders of magnitude larger than 5 ppb precision of the parity violating asymmetry. To better understand this parity conserving background, the Q{sub weak} Collaboration has performed elastic scattering measurements with fully transversely polarized electron beam on the proton and aluminum. This dissertation presents the analysis of the 3% measurement (1.3% statistical and 2.6% systematic) of beam normal single spin asymmetry in electronproton scattering at a Q2 of 0.025 (GeV/c)2. It is the most precise existing measurement of beam normal single spin asymmetry available at the time. A measurement of this precision helps to improve the theoretical models on beam normal single spin asymmetry and thereby our understanding of the doubly virtual Compton scattering process.

  7. Long-range correlations of serial FEV1 measurements in emphysematous patients and normal subjects

    DEFF Research Database (Denmark)

    Dirksen, A; Holstein-Rathlou, N H; Madsen, F

    1998-01-01

    are autocorrelated. The purpose of this study was to describe the correlation structure in time series of FEV1 measurements. Nineteen patients with severe alpha1-antitrypsin deficiency (phenotype PiZ) and moderate to severe emphysema and two subjects with normal lungs were followed for several years with daily self......In obstructive lung disease the annual change in lung function is usually estimated from serial measurements of forced expiratory volume in 1 s (FEV1). Frequent measurements in each patient may not improve this estimate because data are not statistically independent; i.e., the measurements...... measurements show long-range correlations. The practical implication is that FEV1 need not be measured more often than once every 3 mo in studies of the long-term trends in lung function....

  8. Differential Intracochlear Sound Pressure Measurements in Normal Human Temporal Bones

    Science.gov (United States)

    Nakajima, Hideko Heidi; Dong, Wei; Olson, Elizabeth S.; Merchant, Saumil N.; Ravicz, Michael E.; Rosowski, John J.

    2009-02-01

    We present the first simultaneous sound pressure measurements in scala vestibuli and scala tympani of the cochlea in human cadaveric temporal bones. Micro-scale fiberoptic pressure sensors enabled the study of differential sound pressure at the cochlear base. This differential pressure is the input to the cochlear partition, driving cochlear waves and auditory transduction. Results showed that: pressure of scala vestibuli was much greater than scala tympani except at low and high frequencies where scala tympani pressure affects the input to the cochlea; the differential pressure proved to be an excellent measure of normal ossicular transduction of sound (shown to decrease 30-50 dB with ossicular disarticulation, whereas the individual scala pressures were significantly affected by non-ossicular conduction of sound at high frequencies); the middle-ear gain and differential pressure were generally bandpass in frequency dependence; and the middle-ear delay in the human was over twice that of the gerbil. Concurrent stapes velocity measurements allowed determination of the differential impedance across the partition and round-window impedance. The differential impedance was generally resistive, while the round-window impedance was consistent with a compliance in conjunction with distributed inertia and damping. Our techniques can be used to study inner-ear conductive pathologies (e.g., semicircular dehiscence), as well as non-ossicular cochlear stimulation (e.g., round-window stimulation) - situations that cannot be completely quantified by measurements of stapes velocity or scala-vestibuli pressure by themselves.

  9. 17 CFR 402.2d - Appendix D-Modification of § 240.15c3-1d of this title, relating to satisfactory subordination...

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Appendix D-Modification of § 240.15c3-1d of this title, relating to satisfactory subordination agreements, for purposes of § 402.2...—Modification of § 240.15c3-1d of this title, relating to satisfactory subordination agreements, for purposes of...

  10. Measurement of the uterus and gestation sac by ultrasound in early normal and abnormal pregnancy.

    Science.gov (United States)

    Chandra, M; Evans, L J; Duff, G B

    1981-01-14

    Uterine volumes measured by two different ultrasonic methods, and gestation sac volumes in early normal pregnancy are reported. The results obtained for uterine volume measurements are compared. Methods using measurements obtained from only a longitudinal scan were simpler but slightly less accurate. Uterine volumes were also calculated in a series of patients with pregnancy complicated by threatened abortion. The accuracy of the prediction of the outcome of the pregnancy, based solely on uterine volume was 71 percent. Uterine volume measurement is most useful in identifying cases of missed abortion where the period of gestation is known.

  11. Comparison of choroidal thickness measurements between spectral-domain OCT and swept-source OCT in normal and diseased eyes

    Directory of Open Access Journals (Sweden)

    Zafar S

    2016-11-01

    Full Text Available Sidra Zafar,1 MA Rehman Siddiqui,2,3 Rida Shahzad1 1Medical College, Aga Khan University Hospital, 2Department of Ophthalmology, Shahzad Eye Hospital, 3South City Hospital, Karachi, Pakistan Purpose: Sub-foveal choroidal thickness (SFCT is affected in many ocular diseases. The aim of this study was to compare SFCT measurements between Topcon 3D 2000 spectral-domain optical coherence tomography (SD-OCT and Topcon swept-source OCT (SS-OCT, with different laser wavelengths, in normal and diseased populations. Materials and methods: This was a prospective, cross-sectional, noninterventional study including 27 normal volunteers and 27 participants with retinal disease. OCT scans were performed sequentially and under standardized conditions using both SD-OCT and SS-OCT. The OCT scans were evaluated by two independent graders. Paired t-tests and intraclass correlation coefficients (ICCs were used to assess the statistically significant difference between SFCT measurements as measured by the two devices. Results: Mean SFCT measurements for all 54 participants were 264.9±103.1 µm using SD-OCT (range: 47–470 µm and 278.5±110.5 µm using SS-OCT (range: 56–502 µm, with an inter-device ICC of 0.850. Greater variability was noted in the diseased eyes. Inter-device ICCs were 0.870 (95% CI; 0.760–0.924 and 0.840 (95% CI; 0.654–0.930 for normal and diseased eyes, respectively. However, the difference was not statistically significant (P=0.132. Conclusion: Both machines reliably measure SFCT. Larger studies are needed to confirm these findings. Keywords: choroidal imaging, diseased, normal, SD-OCT, SS-OCT

  12. Quantitative measurement of normal and hydrocephalic cerebrospinal fluid flow using phase contrast cine MR imaging

    International Nuclear Information System (INIS)

    Katayama, Shinji; Asari, Shoji; Ohmoto, Takashi

    1993-01-01

    Measurements of the cerebrospinal fluid (CSF) flow using phase contrast cine magnetic resonance (MR) imaging were performed on a phantom, 12 normal subjects and 20 patients with normal pressure hydrocephalus (NPH). The phantom study demonstrated the applicability of phase contrast in quantitative measurement of the slow flow. The CSF flows of the normal subjects showed a consistent pattern with a to-and-fro movement of the flow in the anterior subarachnoid space at the C2/3 level, and they were dependent on the cardiac cycle in all subjects. However, the patients with NPH showed variable patterns of the CSF pulsatile flow and these patterns could be divided into four types according to velocity and amplitude. The amplitudes of each type were as follows: type 0 (n=1), 87.6 mm; type I (n=2), 58.2 mm (mean); type II (n=6), 48.0±5.0 mm (mean±SEM); and type III (n=11), 19.9±1.8 mm (mean±SEM). The decrease of the amplitudes correlated to a worsening of the clinical symptoms. After the shunting operation, the amplitude of to-and-fro movement of the CSF increased again in the patients with NPH who improved clinically. Some of the type III cases were reclassified type II, I and 0 and also one of the type II cases changed type I after the shunting operation. We conclude that the phase contrast cine MR imaging is a practically and clinically applicable technique for the quantitative measurement of the CSF flow. (author)

  13. Comparative ultrasound measurement of normal thyroid gland ...

    African Journals Online (AJOL)

    2011-08-31

    Aug 31, 2011 ... the normal thyroid gland has a homogenous increased medium level echo texture. The childhood thyroid gland dimension correlates linearly with age and body surface unlike adults. [14] Iodothyronine (T3) and thyroxine (T4) are thyroid hormones which function to control the basal metabolic rate (BMR).

  14. Modified Grice-Green subtalar arthrodesis performed using a partial fibular graft yields satisfactory results in patients with cerebral palsy.

    Science.gov (United States)

    Güven, Melih; Tokyay, Abbas; Akman, Budak; Encan, Mehmet E; Altintaş, Faik

    2016-03-01

    The aim of this study was to report the experience with the use of a modified Grice-Green technique, which was performed using a partial subperiosteal fibular bone graft because of valgus unstable foot in children with cerebral palsy. Fifteen feet of 11 patients were evaluated on the basis of the appearance of the feet, clinical symptoms, and radiographic measurements. After an average follow-up duration of 24 (9-39) months, all feet showed satisfactory clinical and radiological results. Solid fusion and sustained correction took place in all feet. The gap at the donor site was bridged with new bone in all cases. No donor-site morbidity was detected. This modification of the Grice-Green technique can be used effectively in the correction of planovalgus foot in cerebral palsy.

  15. CT measurement of normal pericardial thickness in adults on computed tomography

    International Nuclear Information System (INIS)

    Choi, Young Woo; Park, Chan Sup; Jeon, Yong Sun; Bae, In Young; Choi, Sung Gyu; Koo, Jin Hoe; Chung, Won Kyun

    1998-01-01

    The purpose of this study was to establish, using computed tomography, the normal thickness of the pericardium in adults. Materials and Methods: CT scans of 50 patients, including sections through the level of the heart, were reviewed. Patients were excluded if there were any suspicions of pericardial abnormality such as infectious or neoplastic diseases. Twenty-four of the 50 were men and 26 were women; their mean age was 47.0(range,18-76) years. We measured pericardial thickness at the level of the right ventricle, interventricular septum and left ventricle, and also compared pericardial thickness in terms of age and sex. Results: In all patients, the pericardium was observed in the right ventricular region; in 41 (82%) at the interventricular septum; and in 41 (82%) along the left ventricle. The mean thickness of normal pericardium at the level of the right ventricle, interventricular septum, and left ventricle was 1.8 mm ± 0.5 mm, 1.8 mm ± 0.4 mm, and 1.7 mm ± 0.5 mm, respectively. No statistically significant correlation was apparent between pericardial thickness and age group (p > 0.63, ANOVA test). Mean pericardial thickness was 1.9 mm ± 0.6 mm in males and 1.7 mm ± 0.4 mm in females; thus, no statistically significant correlation was apparent between pericardial thickness and sex (p >0.29, Student's t-test). Conclusion: The pericardium was best visualized in sections through the right ventricle.The mean thickness of normal pericardium was 1.8 mm ± 0.5 mm and pericardial thickness did not differ according to age or sex

  16. New experimental device for high-temperature normal spectral emissivity measurements of coatings

    International Nuclear Information System (INIS)

    Honnerová, Petra; Martan, Jiří; Kučera, Martin; Honner, Milan; Hameury, Jacques

    2014-01-01

    A new experimental device for normal spectral emissivity measurements of coatings in the infrared spectral range from 1.38 μm to 26 μm and in the temperature range from 550 K to 1250 K is presented. A Fourier transform infrared spectrometer (FTIR) is used for the detection of sample and blackbody spectral radiation. Sample heating is achieved by a fiber laser with a scanning head. Surface temperature is measured by two methods. The first method uses an infrared camera and a reference coating with known effective emissivity, the second method is based on the combination of Christiansen wavelength with contact and noncontact surface temperature measurement. Application of the method is shown on the example of a high-temperature high-emissivity coating. Experimental results obtained with this apparatus are compared with the results performed by a direct method of Laboratoire National d’Essais (LNE) in France. The differences in the spectra are analyzed. (paper)

  17. Reflectance Measures from Infant Ears With Normal Hearing and Transient Conductive Hearing Loss.

    Science.gov (United States)

    Voss, Susan E; Herrmann, Barbara S; Horton, Nicholas J; Amadei, Elizabeth A; Kujawa, Sharon G

    2016-01-01

    The objective is to develop methods to utilize newborn reflectance measures for the identification of middle-ear transient conditions (e.g., middle-ear fluid) during the newborn period and ultimately during the first few months of life. Transient middle-ear conditions are a suspected source of failure to pass a newborn hearing screening. The ability to identify a conductive loss during the screening procedure could enable the referred ear to be either (1) cleared of a middle-ear condition and recommended for more extensive hearing assessment as soon as possible, or (2) suspected of a transient middle-ear condition, and if desired, be rescreened before more extensive hearing assessment. Reflectance measurements are reported from full-term, healthy, newborn babies in which one ear referred and one ear passed an initial auditory brainstem response newborn hearing screening and a subsequent distortion product otoacoustic emission screening on the same day. These same subjects returned for a detailed follow-up evaluation at age 1 month (range 14 to 35 days). In total, measurements were made on 30 subjects who had a unilateral refer near birth (during their first 2 days of life) and bilateral normal hearing at follow-up (about 1 month old). Three specific comparisons were made: (1) Association of ear's state with power reflectance near birth (referred versus passed ear), (2) Changes in power reflectance of normal ears between newborn and 1 month old (maturation effects), and (3) Association of ear's newborn state (referred versus passed) with ear's power reflectance at 1 month. In addition to these measurements, a set of preliminary data selection criteria were developed to ensure that analyzed data were not corrupted by acoustic leaks and other measurement problems. Within 2 days of birth, the power reflectance measured in newborn ears with transient middle-ear conditions (referred newborn hearing screening and passed hearing assessment at age 1 month) was significantly

  18. Age-matched normal values and topographic maps for regional cerebral blood flow measurements by Xe-133 inhalation

    International Nuclear Information System (INIS)

    Matsuda, H.; Maeda, T.; Yamada, M.; Gui, L.X.; Tonami, N.; Hisada, K.

    1984-01-01

    The relationship between normal aging and regional cerebral blood flow (rCBF) computed as initial slope index (ISI) by Fourier method was investigated in 105 right-handed healthy volunteers (132 measurements) by Xe-133 inhalation method, and age-matched normal values were calculated. Mean brain ISI values showed significant negative correlation with advancing age (r . 0.70, p less than 0.001), and the regression line and its 95% confidence interval was Y . -0.32 (X - 19) + 63.5 +/- 11.2 (19 less than or equal to X less than or equal to 80). Regional ISI values also showed significant negative correlations for the entire brain (p less than 0.001). The regional reductions of ISI values with advancing age were significantly greater in the regional distribution of the middle cerebral arteries bilaterally, compared with regions in the distribution of the other arteries (p less than 0.05). Therefore, measured rCBF values for patients must be compared to age-matched normal values for mean hemispheric and each region examined. Two kinds of topographic maps, brain map showing rCBF compared to age-matched normal values and showing hemispheric differences were made by dividing patient's values by the 95% confidence limits for age-matched normal values and displaying laterality index calculated as follows, respectively. (formula; see text) These maps were useful for evaluating significantly decreased or increased regions and regional hemispheric differences

  19. Spinal cord normalization in multiple sclerosis.

    Science.gov (United States)

    Oh, Jiwon; Seigo, Michaela; Saidha, Shiv; Sotirchos, Elias; Zackowski, Kathy; Chen, Min; Prince, Jerry; Diener-West, Marie; Calabresi, Peter A; Reich, Daniel S

    2014-01-01

    Spinal cord (SC) pathology is common in multiple sclerosis (MS), and measures of SC-atrophy are increasingly utilized. Normalization reduces biological variation of structural measurements unrelated to disease, but optimal parameters for SC volume (SCV)-normalization remain unclear. Using a variety of normalization factors and clinical measures, we assessed the effect of SCV normalization on detecting group differences and clarifying clinical-radiological correlations in MS. 3T cervical SC-MRI was performed in 133 MS cases and 11 healthy controls (HC). Clinical assessment included expanded disability status scale (EDSS), MS functional composite (MSFC), quantitative hip-flexion strength ("strength"), and vibration sensation threshold ("vibration"). SCV between C3 and C4 was measured and normalized individually by subject height, SC-length, and intracranial volume (ICV). There were group differences in raw-SCV and after normalization by height and length (MS vs. HC; progressive vs. relapsing MS-subtypes, P normalization by length (EDSS:r = -.43; MSFC:r = .33; strength:r = .38; vibration:r = -.40), and height (EDSS:r = -.26; MSFC:r = .28; strength:r = .22; vibration:r = -.29), but diminished with normalization by ICV (EDSS:r = -.23; MSFC:r = -.10; strength:r = .23; vibration:r = -.35). In relapsing MS, normalization by length allowed statistical detection of correlations that were not apparent with raw-SCV. SCV-normalization by length improves the ability to detect group differences, strengthens clinical-radiological correlations, and is particularly relevant in settings of subtle disease-related SC-atrophy in MS. SCV-normalization by length may enhance the clinical utility of measures of SC-atrophy. Copyright © 2014 by the American Society of Neuroimaging.

  20. Elements in normal and cirrhotic human liver. Potassium, iron, copper, zinc and bromine measured by X-ray fluorescence spectrometry

    DEFF Research Database (Denmark)

    Laursen, J.; Milman, N.; Leth, Peter Mygind

    1990-01-01

    Various elements (K, Fe, Cu, Zn, Br) were measured by X-ray flourescence spectrometry in cellular and connective tissue fractions of normal and cirrhotic liver samples obtained at autopsy. Normal livers: 32 subjects (16 males, 16 females) median age 69 years. Cirrhotic livers: 14 subjects (13 mal...

  1. Identical bands at normal deformation: Necessity of going beyond the mean-field approach

    International Nuclear Information System (INIS)

    Sun, Y.; Wu, C.; Feng, D.H.; Egido, J.L.; Guidry, M.

    1996-01-01

    The validity of BCS theory has been questioned because the appearance of normally deformed identical bands in odd and even nuclei seems to contradict the conventional understanding of the blocking effect. This problem is examined with the projected shell model (PSM), which projects good angular momentum states and includes many-body correlations in both deformation and pairing channels. Satisfactory reproduction of identical band data by the PSM suggests that it may be necessary to go beyond the mean field to obtain a quantitative account of identical bands. copyright 1996 The American Physical Society

  2. Proficiency testing of electromagnetic compatibility (EMC) labs in Brazil by measurement comparisons

    International Nuclear Information System (INIS)

    Guimarães, Jorge Vallim; Dias, Maurício Henrique Costa; Dos Santos, José Carlos Araujo

    2009-01-01

    This work reports the analysis and main results of a recently concluded proficiency testing round with the major electromagnetic compatibility (EMC) laboratories in Brazil. Seven labs conducted radiated emission measurements at their test facilities under the coordination of an independent third party supervised by the Brazilian accreditation body, INMETRO. Six of them are currently the only labs accredited on EMC measurements in Brazil. The guidelines of international standards such as ISO/IEC Guide 43 and ISO 13528 were followed, while the scope of the tests focused on EMC compliance of information technology devices, based on CISPR 22. A multi-tone signal generator was specifically designed and assembled for the present proficiency testing conditions. Statistical metrics such as z-score and normalized error have been adopted to assess global and individual performances of the participant laboratories. The normalized error indicated 10 unacceptable results out of 35 results, while only 3 out of 35 z-scores were out of the acceptance range. Considering that the participant labs are actually only for test measurements (not for calibration), the overall performance may be taken as satisfactory, based on the fact that the z-score should be used in this case

  3. Surrogacy assessment using principal stratification when surrogate and outcome measures are multivariate normal.

    Science.gov (United States)

    Conlon, Anna S C; Taylor, Jeremy M G; Elliott, Michael R

    2014-04-01

    In clinical trials, a surrogate outcome variable (S) can be measured before the outcome of interest (T) and may provide early information regarding the treatment (Z) effect on T. Using the principal surrogacy framework introduced by Frangakis and Rubin (2002. Principal stratification in causal inference. Biometrics 58, 21-29), we consider an approach that has a causal interpretation and develop a Bayesian estimation strategy for surrogate validation when the joint distribution of potential surrogate and outcome measures is multivariate normal. From the joint conditional distribution of the potential outcomes of T, given the potential outcomes of S, we propose surrogacy validation measures from this model. As the model is not fully identifiable from the data, we propose some reasonable prior distributions and assumptions that can be placed on weakly identified parameters to aid in estimation. We explore the relationship between our surrogacy measures and the surrogacy measures proposed by Prentice (1989. Surrogate endpoints in clinical trials: definition and operational criteria. Statistics in Medicine 8, 431-440). The method is applied to data from a macular degeneration study and an ovarian cancer study.

  4. Computed tomography measurements of the normal and the pathologic cochlea in children

    International Nuclear Information System (INIS)

    Teissier, Natacha; Abbeele, Thierry van den; Sebag, Guy; Elmaleh-Berges, Monique

    2010-01-01

    Radiological investigation is frequently undertaken to assess the aetiology of sensorineural hearing loss (SNHL). To establish the CT measurements of the normal cochlea in children and to determine radiological criteria correlated with SNHL. A retrospective study of temporal bone CT performed in 159 children, age range from 3 days to 16 years between February 1999 and July 2004. A control group (n = 88) comprised children without SNHL; the SNHL group comprised 71 children. The width of the second turn of the cochlea (CW), the cochlear height (CH), and the width of the bony canal for the cochlear nerve (WCN) were measured on a reference plane containing the modiolus, the posterior semicircular canal, the footplate, and the stapes arch. Width of the canal measurements ≤1.7 mm or ≥2.5 mm supported the diagnosis of SNHL with a specificity of 97% and 91%, respectively. Cochlear width was found to be significantly smaller in the SNHL group (5.61 ± 0.51 mm) than in the control group (5.75 ± 0.31 mm, P < 0.02), a size <5.4 mm being highly suggestive of SNHL with a specificity of 90%. No significant variations of all measurements were found with age. Appropriate measurements of WCN and CW are highly correlated with SNHL. (orig.)

  5. A novel approach for evaluating acceptable intra-operative correction of lower limb alignment in femoral and tibial malunion using the deviation angle of the normal contralateral knee.

    Science.gov (United States)

    Wu, Chi-Chuan

    2014-03-01

    A simple and appropriate approach for evaluating an acceptable alignment of bone around the knee during operation has not yet been reported. Thirty-five men and 35 women presenting with nonunion or malunion of the unilateral femoral shaft were included in the first study. Using the standing scanograph, the contralateral normal lower extremity was measured to determine the normal deviation angle (DA) of the medial malleolus when the medial aspect of the knee was placed in the midline of the body. In the second study, the normal DA from individual patients was used as a reference to evaluate knee alignment during operation in 40 other patients presenting with distal femoral or proximal tibial nonunion or malunion. The clinical and knee functional outcomes of these 40 patients were investigated. The average normal DA was 4.2° in men and 6.0° in women (palignment was maintained in all 30 patients with fracture union. Satisfactory function of the knee was achieved in 28 patients (82%, palignment of bone around the knee during operation. Level IV, Case series. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Prodrugs designed to discriminate pathological (tumour) and physiological (normal tissue) hypoxia

    International Nuclear Information System (INIS)

    Wilson, W.R.; Patterson, A.V.

    2003-01-01

    There is now abundant evidence that hypoxic contributes to treatment failure in radiation therapy. As a target for therapeutic intervention, hypoxia is especially attractive because it is a common feature of most human tumours and therefore a potential 'pan target' across many tumour types. However, attempts to exploit hypoxia face the problem that oxygen concentrations in some normal tissues are also heterogeneous and that O 2 distributions in tumours and normal tissues overlap. Simply adjusting the K value (O 2 concentration for 50% inhibition of activation) does not provide a satisfactory solution. Bioreductive drugs like tirapazamine with high K values are activated significantly in several normal tissues, while nitro compounds and quinones with low K values spare the hypoxic tumour cells at 'intermediate' O 2 tensions (1-10 mM O 2 ) which are considered to be major contributors to tumour radioresistance. A potential strategy for overcoming this dilemma is to design prodrugs that are activated only at very low K values, but give relatively stable cytotoxic metabolites capable of diffusing to cells at higher O 2 concentrations. This approach redefines the therapeutic target as cells adjacent to zones of pathological hypoxia ( 2 ), providing discrimination from physiological hypoxia in normal tissues. Detecting bioreductive prodrugs capable of providing bystander killing of this kind is not straightforward. We have adapted a multicellular layer (MCL) co-culture model for quantifying bystander effects in GDEPT (Wilson et al., Cancer Res., 62: 1425-1432, 2002), and have used this to measure bystander effects of hypoxia-activated prodrugs. This model uses differences in metabolic activation of bioreductive drugs between A459 cell lines with low and high cytochrome P450 reductase activity, rather than O 2 gradients, to effect localised prodrug activation. It shows that TPZ and the nitroimidazole RSU-1069 have little or no bystander effect, but that dinitrobenzamide

  7. Measurement of plasma histamine: description of an improved method and normal values

    International Nuclear Information System (INIS)

    Dyer, J.; Warren, K.; Merlin, S.; Metcalfe, D.D.; Kaliner, M.

    1982-01-01

    The single isotopic-enzymatic assay of histamine was modified to increase its sensitivity and to facilitate measurement of plasma histamine levels. The modification involved extracting 3 H-1-methylhistamine (generated by the enzyme N-methyltransferase acting on histamine in the presence of S-[methyl- 3 H]-adenosyl-L-methionine) into chloroform and isolating the 3 H-1-methylhistamine by thin-layer chromatography (TLC). The TLC was developed in acetone:ammonium hydroxide (95:10), and the methylhistamine spot (Rf . 0.50) was identified with an o-phthalaldehyde spray, scraped from the plate, and assayed in a scintillation counter. The assay in plasma demonstrated a linear relationship from 200 to 5000 pg histamine/ml. Plasma always had higher readings than buffer, and dialysis of plasma returned these values to the same level as buffer, suggesting that the baseline elevations might be attributable to histamine. However, all histamine standard curves were run in dialyzed plasma to negate any additional influences plasma might exert on the assay. The arithmetic mean (+/- SEM) in normal plasma histamine was 318.4 +/- 25 pg/ml (n . 51), and the geometric mean was 280 +/- 35 pg/ml. Plasma histamine was significantly elevated by infusion of histamine at 0.05 to 1.0 micrograms/kg/min or by cold immersion of the hand of a cold-urticaria patient. Therefore this modified isotopic-enzymatic assay of histamine is extremely sensitive, capable of measuring fluctuations in plasma histamine levels within the normal range, and potentially useful in analysis of the role histamine plays in human physiology

  8. Shear wave velocity measurements using acoustic radiation force impulse in young children with normal kidneys versus hydronephrotic kidneys

    International Nuclear Information System (INIS)

    Shon, Beom Seok; Kim, Myung Joon; Han, Sang Won; Im, Young Jae; Lee, Mi Jung

    2014-01-01

    To measure shear wave velocities (SWVs) by acoustic radiation force impulse (ARFI) ultrasound elastography in normal kidneys and in hydronephrotic kidneys in young children and to compare SWVs between the hydronephrosis grades. This study was approved by an institutional review board, and informed consent was obtained from the parents of all the children included. Children under the age of 24 months were prospectively enrolled. Hydronephrosis grade was evaluated on ultrasonography, and three valid ARFI measurements were attempted using a high-frequency transducer for both kidneys. Hydronephrosis was graded from 0 to 4, and high-grade hydronephrosis was defined as grades 3 and 4. Fifty-one children underwent ARFI measurements, and three valid measurements for both kidneys were obtained in 96% (49/51) of the patients. Nineteen children (38.8%) had no hydronephrosis. Twenty-three children (46.9%) had unilateral hydronephrosis, and seven children (14.3%) had bilateral hydronephrosis. Seven children had ureteropelvic junction obstruction (UPJO). Median SWVs in kidneys with high-grade hydronephrosis (2.02 m/sec) were higher than those in normal kidneys (1.75 m/sec; P=0.027). However, the presence of UPJO did not influence the median SWVs in hydronephrotic kidneys (P=0.362). Obtaining ARFI measurements of the kidney is feasible in young children with median SWVs of 1.75 m/sec in normal kidneys. Median SWVs increased in high-grade hydronephrotic kidneys but were not different between hydronephrotic kidneys with and without UPJO.

  9. Shear wave velocity measurements using acoustic radiation force impulse in young children with normal kidneys versus hydronephrotic kidneys

    Energy Technology Data Exchange (ETDEWEB)

    Shon, Beom Seok; Kim, Myung Joon; Han, Sang Won; Im, Young Jae; Lee, Mi Jung [Severance Children' s Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-04-15

    To measure shear wave velocities (SWVs) by acoustic radiation force impulse (ARFI) ultrasound elastography in normal kidneys and in hydronephrotic kidneys in young children and to compare SWVs between the hydronephrosis grades. This study was approved by an institutional review board, and informed consent was obtained from the parents of all the children included. Children under the age of 24 months were prospectively enrolled. Hydronephrosis grade was evaluated on ultrasonography, and three valid ARFI measurements were attempted using a high-frequency transducer for both kidneys. Hydronephrosis was graded from 0 to 4, and high-grade hydronephrosis was defined as grades 3 and 4. Fifty-one children underwent ARFI measurements, and three valid measurements for both kidneys were obtained in 96% (49/51) of the patients. Nineteen children (38.8%) had no hydronephrosis. Twenty-three children (46.9%) had unilateral hydronephrosis, and seven children (14.3%) had bilateral hydronephrosis. Seven children had ureteropelvic junction obstruction (UPJO). Median SWVs in kidneys with high-grade hydronephrosis (2.02 m/sec) were higher than those in normal kidneys (1.75 m/sec; P=0.027). However, the presence of UPJO did not influence the median SWVs in hydronephrotic kidneys (P=0.362). Obtaining ARFI measurements of the kidney is feasible in young children with median SWVs of 1.75 m/sec in normal kidneys. Median SWVs increased in high-grade hydronephrotic kidneys but were not different between hydronephrotic kidneys with and without UPJO.

  10. What are the factors that influence the attainment of satisfactory energy intake in pediatric intensive care unit patients receiving enteral or parenteral nutrition?

    Science.gov (United States)

    de Menezes, Fernanda Souza; Leite, Heitor Pons; Nogueira, Paulo Cesar Koch

    2013-01-01

    Children admitted to the intensive care unit (ICU) are at risk of inadequate energy intake. Although studies have identified factors contributing to an inadequate energy supply in critically ill children, they did not take into consideration the length of time during which patients received their estimated energy requirements after having achieved a satisfactory energy intake. This study aimed to identify factors associated with the non-attainment of estimated energy requirements and consider the time this energy intake is maintained. This was a prospective study involving 207 children hospitalized in the ICU who were receiving enteral and/or parenteral nutrition. The outcome variable studied was whether 90% of the estimated basal metabolic rate was maintained for at least half of the ICU stay (satisfactory energy intake). The exposure variables for outcome were gender, age, diagnosis, use of vasopressors, malnutrition, route of nutritional support, and Pediatric Index of Mortality and Pediatric Logistic Organ Dysfunction scores. Satisfactory energy intake was attained by 20.8% of the patients, within a mean time of 5.07 ± 2.48 d. In a multivariable analysis, a diagnosis of heart disease (odds ratio 3.62, 95% confidence interval 1.03-12.68, P = 0.045) increased the risk of insufficient energy intake, whereas malnutrition (odds ratio 0.43, 95% confidence interval 0.20-0.92, P = 0.030) and the use of parenteral nutrition (odds ratio 0.34, 95% confidence interval 0.15-0.77, P = 0.001) were protective factors against this outcome. A satisfactory energy intake was reached by a small proportion of patients during their ICU stay. Heart disease was an independent risk factor for the non-attainment of satisfactory energy intake, whereas malnutrition and the use of parenteral nutrition were protective factors against this outcome. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. One-stop endoscopic hernia surgery: efficient and satisfactory.

    Science.gov (United States)

    Voorbrood, C E H; Burgmans, J P J; Clevers, G J; Davids, P H P; Verleisdonk, E J M M; Schouten, N; van Dalen, T

    2015-06-01

    One-stop surgery offers patients diagnostic work-up and subsequent surgical treatment on the same day. In the present study, patient satisfaction and efficiency from an institutional perspective were evaluated in patients who were referred for one-stop endoscopic inguinal hernia repair. In a high-volume inguinal hernia clinic, all consecutive patients referred for one-stop surgical treatment, were registered prospectively. An instructed secretary screened patients for eligibility for the one-stop option when the appointment was made. Totally extraperitoneal hernia repair under general anaesthesia was the preferred operative technique. Patient's satisfaction, successful day surgery and institutional efficiency were evaluated. Between January 2010 and January 2012 a total of 349 patients (17 % of all patients in the hernia clinic) were referred for one-stop hernia repair. Mean age was 47.5 years and 96.3 % were males. Three hundred thirty-six patients underwent hernia surgery on the same day (96.3 %). In thirteen patients (3.7 %) no operative repair was done on the day of presentation due to an incorrect diagnosis (n = 7), a watchful waiting policy for asymptomatic hernia (n = 3), rescheduling due to a large scrotal hernia, and there were two "no shows". Following hernia repair 97 % of the patients were discharged on the same day, while ten patients required hospitalization. Based on the questionnaires the main satisfaction score among patients was 9.0 (8.89-9.17 95 % CI) on a scale ranging from 0 to 10. One-stop hernia surgery is feasible and satisfactory from an institutional as well as from a patient's perspective.

  12. Bicruciate-retaining Total Knee Replacement Provides Satisfactory Function and Implant Survivorship at 23 Years.

    Science.gov (United States)

    Pritchett, James W

    2015-07-01

    One of the goals of a TKA is to approximate the function of a normal knee. Preserving the natural ligaments might provide a method of restoring close to normal function. Sacrifice of the ACL is common and practical during a TKA. However, this ligament is functional in more than 60% of patients undergoing a TKA and kinematic studies support the concept of bicruciate-retaining (that is, ACL-preserving) TKA; however, relatively few studies have evaluated patients treated with bicruciate-retaining TKA implants. I asked: (1) what is the long-term (minimum 20-year) survivorship, (2) what are the functional results, and (3) what are the reasons for revision of bicruciate-retaining knee arthroplasty prostheses? From January 1989 to September 1992, I performed 639 total knee replacements in 537 patients. Of these, 489 were performed in 390 patients using a bicruciate-retaining, minimally constrained device. During the period in question, this knee prosthesis was used for all patients observed intraoperatively to have an intact, functional ACL with between 15° varus and 15° valgus joint deformity. There were 234 women and 156 men with a mean age at surgery of 65 years (range, 42-84 years) and a primary diagnosis of osteoarthritis in 89%. The patella was resurfaced in all knees. The mean followup was 23 years (range, 20-24 years). At the time of this review, 199 (51%) patients had died and 31 (8%) patients were lost to followup, leaving 160 (41%) patients (214 knees) available for review. Component survivorship was determined by competing-risks analysis and Kaplan Meier survivorship analysis with revision for any reason as the primary endpoint. Patients were evaluated every 2 years to assess ROM, joint laxity, knee stability, and to determine American Knee Society scores. The Kaplan-Meier survivorship was 89% (95% CI, 82%-93%) at 23 years with revision for any reason as the endpoint. Competing-risks survivorship was 94% (95% CI, 91%%-96 %) at 23 years. At followup, the mean

  13. Consideration of Normal Variation of Perfusion Measurements in the Quantitative Analysis of Myocardial Perfusion SPECT: Usefulness in Assessment of Viable Myocardium

    International Nuclear Information System (INIS)

    Paeng, Jin Chul; Lim, Il Han; Kim, Ki Bong; Lee, Dong Soo

    2008-01-01

    Although automatic quantification software of myocardial perfusion SPECT provides highly objective and reproducible quantitative measurements, there is still some limitation in the direct use of quantitative measurements. In this study we derived parameters using normal variation of perfusion measurements, and tried to test the usefulness of these parameters. In order to calculate normal variation of perfusion measurements on myocardial perfusion SPECT, 55 patients (M:F=28:27) of low-likelihood for coronary artery disease were enrolled and 201 Tl rest / 99m Tc-MIBI stress SPECT studies were performed. Using 20-segment model, mean (m) and standard deviation (SD) of perfusion were calculated in each segment. As a myocardial viability assessment group, another 48 patients with known coronary artery disease, who underwent coronary artery bypass graft surgery (CABG) were enrolled. 201 Tl rest / 99m Tc-MIBI stress / 201 Tl 24-hr delayed SPECT was performed before CABG and SPECT was followed up 3 months after CABG. From the preoperative 24-hr delayed SPECT, Q delay (perfusion measurement), Δ delay (Q delay .m) and Z delay ((Q delay .m)/SD) were defined and diagnostic performances of them for myocardial viability were evaluated using area under curve (AUC) on receiver operating characteristic (ROC) curve analysis. Segmental perfusion measurements showed considerable normal variations among segments. In men, the lowest segmental perfusion measurement was 51.8±6.5 and the highest segmental perfusion was 87.0±5.9, and they are 58.7±8.1 and 87.3±6.0, respectively in women. In the viability assessment, Q delay showed AUC of 0.633, while those for Δ delay and Z delay were 0.735 and 0.716, respectively. The AUCs of Δ delay and Z delay were significantly higher than that of Q delay (p=0.001 and 0.018, respectively). The diagnostic performance of Δ delay , which showed highest AUC, was 85% of sensitivity and 53% of specificity at the optimal cutoff of -24.7. On automatic

  14. Fluorescence Spectrum and Decay Measurement for Hsil VS Normal Cytology Differentiation in Liquid Pap Smear Supernatant

    Science.gov (United States)

    Vaitkuviene, A.; Gegzna, V.; Juodkazis, S.; Jursenas, S.; Miasojedovas, S.; Kurtinaitiene, R.; Rimiene, J.; Vaitkus, J.

    2009-06-01

    Cervical smear material contains endo and exocervical cells, mucus and inflammative, immune cells in cases of pathology. Just not destroyed keratinocytes lay on the glass for microscopy. Liquid cytology supernatant apart other diagnostics could be used for photodiagnostic. The spectroscopic parameters suitable for Normal and HSIL cytology groups supernatant differentiation are demonstrated. The dried liquid PAP supernatant fractions—sediment and liquid were investigated. Excitation and emission matrices (EEM), supernatant fluorescence decay measured under 280 nm diode short pulse excitation and fluorescence spectroscopy by excitation with 355 nm laser light were analyzed. The differences between Normal and HSIL groups were statistically proven in the certain spectral regions. Fluorescence decay peculiarities show spectral regions consisting of few fluorophores. Obtained results on fluorescence differences in Normal and HSIL groups' supernatant shows the potency of photodiagnosis application in cervical screening.

  15. Predictors of satisfactory improvements in pain for patients with early rheumatoid arthritis in a treat-to-target study

    NARCIS (Netherlands)

    Klooster, P.M. ten; Vonkeman, H.E.; Voshaar, M.A.; Siemons, L.; Riel, P.L.C.M. van; Laar, M.A.F.J. van de

    2015-01-01

    OBJECTIVE: The aim of this study was to identify baseline predictors of achieving patient-perceived satisfactory improvement (PPSI) in pain after 6 months of treat to target in patients with early RA. METHODS: Baseline and 6 month data were used from patients included in the Dutch Rheumatoid

  16. Brain parenchymal density measurements by CT in demented subjects and normal controls

    International Nuclear Information System (INIS)

    Gado, M.; Danziger, W.L.; Chi, D.; Hughes, C.P.; Coben, L.A.

    1983-01-01

    Parachymal density measurements of 14 regions of gray and white matter from each cerebral hemisphere were made from CT scans of 25 subjects who had varying degrees of dementia as measured by a global Clinical Dementia Rating, and also from CT scans of 33 normal control subjects. There were few significant differences between the two groups in the mean density value for each of the regions examined, although several individual psychometric tests did correlate with density changes. Moreover, for six regions in the cerebral cortex, and for one region in the thalamus of each hemisphere, we found no significant correlation between the gray-white matter density difference and dementia. There was, however, a loss of the discriminability between the gray and white matter with an increase in the size of the ventricles. These findings may be attributed to the loss of white matter volume

  17. Ocular axial length measurement among normal adults using ...

    African Journals Online (AJOL)

    , as visual compromise is a major consequence if they are not diagnosed and managed appropriately. Aim and Objectives: To use magnetic resonance imaging, to determine the normal AL of the eyeball and to establish the association, if any, ...

  18. Is the shortened dental arch still a satisfactory option?

    Science.gov (United States)

    Manola, M; Hussain, F; Millar, B J

    2017-07-21

    Aims Dental practitioners may hold the view that missing posterior teeth should be replaced to ensure a healthy masticatory system and satisfactory oral function. However, the shortened dental arch (SDA) concept is still in use, but after 35 years is it acceptable? This review searches the literature for the evidence and opinions regarding the suitability of the SDA as a current treatment modality.Methods Medline and PubMed databases were searched for relevant terms, all the abstracts were assessed and articles selected according to the pre-set exclusion and inclusion criteria.Results The search yielded 1,895 articles and after the assessment of the abstracts and application of the exclusion and inclusion criteria, 44 articles were selected for this review. These included 11 cohort studies, two longitudinal studies, two animal studies, three cross sectional studies, eight clinical studies and 18 case control studies. There appears to be a trend over the past three decades for more papers to be opposed to the SDA concept.Conclusion Evidence that the SDA causes pathology is lacking. Clinicians, healthcare authorities and patients have shown favourable attitudes towards the SDA and this continues, although there is an increase in studies opposing the concept and some are dissatisfied with this option. The concept remains viable particularly for the medically compromised patient or where restorations are considered unsuitable but further more specific studies are warranted.

  19. A comparison of various "housekeeping" probes for northern analysis of normal and osteoarthritic articular cartilage RNA.

    Science.gov (United States)

    Matyas, J R; Huang, D; Adams, M E

    1999-01-01

    Several approaches are commonly used to normalize variations in RNA loading on Northern blots, including: ethidium bromide (EthBr) fluorescence of 18S or 28S rRNA or autoradiograms of radioactive probes hybridized with constitutively expressed RNAs such as elongation factor-1alpha (ELF), glyceraldehyde-3-phosphate dehydrogenase (G3PDH), actin, 18S or 28S rRNA, or others. However, in osteoarthritis (OA) the amount of total RNA changes significantly and none of these RNAs has been clearly demonstrated to be expressed at a constant level, so it is unclear if any of these approaches can be used reliably for normalizing RNA extracted from osteoarthritic cartilage. Total RNA was extracted from normal and osteoarthritic cartilage and assessed by EthBr fluorescence. RNA was then transferred to a nylon membrane hybridized with radioactive probes for ELF, G3PDH, Max, actin, and an oligo-dT probe. The autoradiographic signal across the six lanes of a gel was quantified by scanning densitometry. When compared on the basis of total RNA, the coefficient of variation was lowest for 28S ethidium bromide fluorescence and oligo-dT (approximately 7%), followed by 18S ethidium bromide fluorescence and G3PDH (approximately 13%). When these values were normalized to DNA concentration, the coefficient of variation exceeded 50% for all signals. Total RNA and the signals for 18S, 28S rRNA, and oligo-dT all correlated highly. These data indicate that osteoarthritic chondrocytes express similar ratios of mRNA to rRNA and mRNA to total RNA as do normal chondrocytes. Of all the "housekeeping" probes, G3PDH correlated best with the measurements of RNA. All of these "housekeeping" probes are expressed at greater levels by osteoarthritic chondrocytes when compared with normal chondrocytes. Thus, while G3PDH is satisfactory for evaluating the amount of RNA loaded, its level of expression is not the same in normal and osteoarthritic chondrocytes.

  20. Neutron total cross-section of hydrogenous and deuterated 1- and 2-propanol and n-butanol measured using the VESUVIO spectrometer

    Science.gov (United States)

    Rodríguez Palomino, L. A.; Dawidowski, J.; Márquez Damián, J. I.; Cuello, G. J.; Romanelli, G.; Krzystyniak, M.

    2017-10-01

    This work presents the total cross sections of a set of normal and deuterated alcohols (hydrogenous 1- and 2-propanol and n-butanol, 1-propanol(OD) and fully deuterated 2-propanol and n-butanol), measured at spectrometer VESUVIO (ISIS spallation neutron source, United Kingdom). Granada's Synthetic Model was applied to describe those systems and a satisfactory agreement with the measured total cross section was achieved in the range of energies from 10-3 to 100 eV. The input parameters of the model were determined from the essential features of the vibrational spectra of the atoms that compose the systems, which were studied using Molecular Dynamics.

  1. A normal colposcopy examination fails to provide psychological reassurance for women who have had low-grade abnormal cervical cytology.

    Science.gov (United States)

    Cotton, S C; Sharp, L; Little, J; Gray, N M; Walker, L G; Whynes, D K; Cruickshank, M E

    2015-06-01

    Worldwide, each year, large numbers of women are referred for colposcopy following low-grade abnormal cervical cytology. Many have no visible abnormality on examination. The risk of cervical intra-epithelial neoplasia grade 2/3 (CIN2/3) in these women is low. It is unknown whether, for women, a normal colposcopy resolves the anxiety which often follows the receipt of an abnormal cytology result. We investigated the prevalence of adverse psychological outcomes over 30 months following a normal colposcopy. This cohort study was nested within the UK TOMBOLA randomized controlled trial. Women aged 20-59 years, with recent low-grade cytology, who had a satisfactory colposcopy examination and normal transformation zone, completed the Hospital Anxiety and Depression Scale (HADS) and Process Outcome Specific Measure (POSM) at recruitment and during follow-up (12, 18, 24 and 30 months post-recruitment). Outcomes included percentages reporting significant anxiety (HADS anxiety subscale score ≥11), significant depression (HADS depression subscale score ≥8) or worries about the result of the next cytology test, cervical cancer, having sex, future fertility and general health at each time point (point prevalence) and during follow-up (cumulative prevalence). The study included 727 women. All psychological measures (except depression) had high prevalence at recruitment, falling substantially by 12 months. During follow-up, the cumulative prevalence of significant anxiety was 27% and significant depression was 21%. The most frequently reported worry was that the next cytology test would be abnormal (cumulative prevalence of 71%; point prevalence of ≥50% at 12 and 18 months). The cumulative prevalence values of worries about cervical cancer, having sex and future fertility were 33%, 20% and 16%, respectively. For some women who have low-grade cytology, a normal colposcopy does not appear to provide psychological reassurance. © 2014 John Wiley & Sons Ltd.

  2. 13C/14C dual isotope breath test measurement of gastric emptying in normal subjects and patients

    International Nuclear Information System (INIS)

    Chew, G.; Bartholomeusz, F.D.L.; Bellon, M.; Chatterton, B.E.

    2000-01-01

    Full text: A more flexible alternative to dual isotope scintigraphy for gastric emptying involves measuring breath C0 2 after administration of absorbable tracers. Method: six patients were given 100g hamburger labelled with 25 MBq 99 Tc m sulphur colloid and 74 KBq 14 C octanoic acid, and 150 ml 10% glucose drink labelled with 8 MBq 67 Ga citrate and ISO mg 13 C acetate and seven normals with 14 C and 13 C labels only. Breath was collected at baseline and then regularly for four hours. The 14 CO 2 and 13 CO 2 activity was measured with liquid scintillation counting and mass spectroscopy. The times to maximum 14 CO 2 , and 13 CO 2 , T max, were determined. Results: Comparison was made between 14 CO 2 T max with scintigraphic retention of 99 Tc m at 100 minutes (SR100m) and 13 CO 2 T max with the scintigraphic half-clearance time of 67 Ga (scint T1/2). In conclusion 14 CO 2 T max and 13 CO 2 T max correlate significantly with SR100m and scint T1/2 respectively. The normal threshold is between 165 and 180 minutes for 14 Co 2 T max; probably > 40 minutes for 13 CO 2 T max but overlap exists between normal and abnormal results in this small preliminary study. Recruitment is to continue to better define normal ranges. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  3. Classifying Normal and Abnormal Status Based on Video Recordings of Epileptic Patients

    Directory of Open Access Journals (Sweden)

    Jing Li

    2014-01-01

    Full Text Available Based on video recordings of the movement of the patients with epilepsy, this paper proposed a human action recognition scheme to detect distinct motion patterns and to distinguish the normal status from the abnormal status of epileptic patients. The scheme first extracts local features and holistic features, which are complementary to each other. Afterwards, a support vector machine is applied to classification. Based on the experimental results, this scheme obtains a satisfactory classification result and provides a fundamental analysis towards the human-robot interaction with socially assistive robots in caring the patients with epilepsy (or other patients with brain disorders in order to protect them from injury.

  4. Measurement of Normal and Friction Forces in a Rolling Process

    DEFF Research Database (Denmark)

    Henningsen, Poul; Arentoft, Mogens; Wanheim, Tarras

    2004-01-01

    by the fric-tion conditions. To achieve this important informa-tion, measurements of the normal pressure and friction stresses in the deformation zone are re-quested. The direction of the friction stresses is changing during the rolling gap. At the entrance of the de-formation zone, the peripherical velocity...... of the roll is higher than for the incoming material, which causes frictional stresses at the material acting in the rolling direction. At the outlet of the rolling gap, the velocity of the deformed material exceeds the velocity of the roll, generating frictional stresses contrary to the direction of rolling....... In a narrow area in the deformation zone, the velocity of the de-formed material is equal to the velocity of the rolls. This area or line is named “neutral line”. The posi-tion of the neutral line depends on friction, reduc-tion ratio, diameter of the rolls, and width of the sheet....

  5. Exercises in anatomy: the normal heart.

    Science.gov (United States)

    Anderson, Robert H; Sarwark, Anne; Spicer, Diane E; Backer, Carl L

    2014-01-01

    In the first of our exercises in anatomy, created for the Multimedia Manual of the European Association of Cardiothoracic Surgery, we emphasized that thorough knowledge of intracardiac anatomy was an essential part of the training for all budding cardiac surgeons, explaining how we had used the archive of congenitally malformed hearts maintained at Lurie Children's Hospital in Chicago to prepare a series of videoclips, demonstrating the salient features of tetralogy of Fallot. In this series of videoclips, we extend our analysis of the normal heart, since for our initial exercise we had concentrated exclusively on the structure of the right ventricular outflow tract. We begin our overview of normal anatomy by emphasizing the need, in the current era, to describe the heart in attitudinally appropriate fashion. Increasingly, clinicians are demonstrating the features of the heart as it is located within the body. It is no longer satisfactory, therefore, to describe these components in a 'Valentine' fashion, as continues to be the case in most textbooks of normal or cardiac anatomy. We then emphasize the importance of the so-called morphological method, which states that structures within the heart should be defined on the basis of their own intrinsic morphology, and not according to other parts, which are themselves variable. We continue by using this concept to show how it is the appendages that serve to distinguish between the atrial chambers, while the apical trabecular components provide the features to distinguish the ventricles. We then return to the cardiac chambers, emphasizing features of surgical significance, in particular the locations of the cardiac conduction tissues. We proceed by examining the cardiac valves, and conclude by providing a detailed analysis of the septal structures. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. C3-6 laminoplasty for cervical spondylotic myelopathy maintains satisfactory long-term surgical outcomes.

    Science.gov (United States)

    Sakaura, Hironobu; Hosono, Noboru; Mukai, Yoshihiro; Iwasaki, Motoki; Yoshikawa, Hideki

    2014-08-01

    Study Design Prospective cohort study. Objective To clarify long-term surgical outcomes of C3-6 laminoplasty preserving muscles attached to the C2 and C7 spinous processes in patients with cervical spondylotic myelopathy (CSM). Methods Twenty patients who underwent C3-6 open-door laminoplasty for CSM and who were followed for 8 to 10 years were included in this study. Myelopathic symptoms were assessed using Japanese Orthopaedic Association (JOA) score. Axial neck pain was graded as severe, moderate, or mild. C2-7 angle was measured using lateral radiographs of the cervical spine before surgery and at final follow-up. Results Mean JOA score before surgery (11.7) was significantly improved to 15.2 at the time of maximum recovery (1 year after surgery), declining slightly to 14.9 by the latest follow-up. Late deterioration of JOA score developed in eight patients, but was unrelated to the cervical spine lesions in each case. No patient suffered from prolonged postoperative axial neck pain at final follow-up. The mean C2-7 angle before surgery (13.8 degrees) significantly increased to 19.2 degrees at final follow-up. Conclusions C3-6 laminoplasty preserving muscles attached to the C2 and C7 spinous processes in patients with CSM maintained satisfactory long-term neurologic improvement with significantly reduced frequencies of prolonged postoperative axial neck pain and loss of C2-7 angle after surgery.

  7. Hyaline cartilage thickness in radiographically normal cadaveric hips: comparison of spiral CT arthrographic and macroscopic measurements.

    Science.gov (United States)

    Wyler, Annabelle; Bousson, Valérie; Bergot, Catherine; Polivka, Marc; Leveque, Eric; Vicaut, Eric; Laredo, Jean-Denis

    2007-02-01

    To assess spiral multidetector computed tomographic (CT) arthrography for the depiction of cartilage thickness in hips without cartilage loss, with evaluation of anatomic slices as the reference standard. Permission to perform imaging studies in cadaveric specimens of individuals who had willed their bodies to science was obtained from the institutional review board. Two independent observers measured the femoral and acetabular hyaline cartilage thickness of 12 radiographically normal cadaveric hips (from six women and five men; age range at death, 52-98 years; mean, 76.5 years) on spiral multidetector CT arthrographic reformations and on coronal anatomic slices. Regions of cartilage loss at gross or histologic examination were excluded. CT arthrographic and anatomic measurements in the coronal plane were compared by using Bland-Altman representation and a paired t test. Differences between mean cartilage thicknesses at the points of measurement were tested by means of analysis of variance. Interobserver and intraobserver reproducibilities were determined. At CT arthrography, mean cartilage thickness ranged from 0.32 to 2.53 mm on the femoral head and from 0.95 to 3.13 mm on the acetabulum. Observers underestimated cartilage thickness in the coronal plane by 0.30 mm +/- 0.52 (mean +/- standard error) at CT arthrography (P cartilage thicknesses at the different measurement points was significant for coronal spiral multidetector CT arthrography and anatomic measurement of the femoral head and acetabulum and for sagittal and transverse CT arthrography of the femoral head (P cartilage thickness from the periphery to the center of the joint ("gradients") were found by means of spiral multidetector CT arthrography and anatomic measurement. Spiral multidetector CT arthrography depicts cartilage thickness gradients in radiographically normal cadaveric hips. (c) RSNA, 2007.

  8. Similarity measurement method of high-dimensional data based on normalized net lattice subspace

    Institute of Scientific and Technical Information of China (English)

    Li Wenfa; Wang Gongming; Li Ke; Huang Su

    2017-01-01

    The performance of conventional similarity measurement methods is affected seriously by the curse of dimensionality of high-dimensional data.The reason is that data difference between sparse and noisy dimensionalities occupies a large proportion of the similarity, leading to the dissimilarities between any results.A similarity measurement method of high-dimensional data based on normalized net lattice subspace is proposed.The data range of each dimension is divided into several intervals, and the components in different dimensions are mapped onto the corresponding interval.Only the component in the same or adjacent interval is used to calculate the similarity.To validate this meth-od, three data types are used, and seven common similarity measurement methods are compared. The experimental result indicates that the relative difference of the method is increasing with the di-mensionality and is approximately two or three orders of magnitude higher than the conventional method.In addition, the similarity range of this method in different dimensions is [0, 1], which is fit for similarity analysis after dimensionality reduction.

  9. Association with isokinetic ankle strength measurements and normal clinical muscle testing in sciatica patients.

    Science.gov (United States)

    Ustun, N; Erol, O; Ozcakar, L; Ceceli, E; Ciner, O Akar; Yorgancioglu, Z R

    2013-01-01

    Sensitive muscle strength tests are needed to measure muscle strength in the diagnosis and management of sciatica patients. The aim of this study was to assess the isokinetic muscle strength in sciatica patients' and control subjects' ankles that exhibited normal ankle muscle strength when measured clinically. Forty-six patients with L5 and/or S1 nerve compression, and whose age, sex, weight, and height matched 36 healthy volunteers, were recruited to the study. Heel-walking, toe-walking, and manual muscle testing were used to perform ankle dorsiflexion and plantar flexion strengths in clinical examination. Patients with normal ankle dorsiflexion and plantar flexion strengths assessed by manual muscle testing and heel-and toe-walking tests were included in the study. Bilateral isokinetic (concentric/concentric) ankle plantar-flexion-dorsiflexion measurements of the patients and controls were performed within the protocol of 30°/sec (5 repetitions). Peak torque and peak torque/body weight were obtained for each ankle motion of the involved limb at 30°/s speed. L5 and/or S1 nerve compression was evident in 46 patients (76 injured limbs). Mean disease duration was two years. The plantar flexion muscle strength of the patients was found to be lower than that of the controls (p=0.036). The dorsiflexion muscle strength of the patients was found to be the same as that of the controls (p=0.211). Isokinetic testing is superior to clinical muscle testing when evaluating ankle plantar flexion torque in sciatica patients. Therefore, isokinetic muscle testing may be helpful when deciding whether to place a patient into a focused rehabilitation program.

  10. Objective assessment of occlusal and coronal characteristics of untreated normals: a measurement study.

    Science.gov (United States)

    Currim, Simone; Wadkar, Prabodh V

    2004-05-01

    To determine whether tooth shape and position are constant within tooth types, dental casts of 68 Indians (age range, 10-32 years; mean, 18.72 years) were analyzed. The casts were selected from a larger sample and met the following criteria: Class I molar and canine relationships; overjet and overbite within normal limits; well-related vertical, transverse, and anteroposterior relationships with pleasing profiles and well-aligned arches; and no supernumerary teeth or large restorations. None of the subjects had received orthodontic treatment, and all were in good health and exhibited normal growth. Crown angulation, inclination, offset of maxillary molar, curve of Spee, crown facial prominence, horizontal crown contour, and vertical crown contour were assessed. Means, standard deviations, and standard errors were calculated. The measurements were compared with Andrews's data on 120 nonorthodontic normal occlusion casts. The Student t test was used to determine the significance of differences between the 2 sets of data. It was found that teeth of the same tooth type have similar values of horizontal and vertical crown contours. Values for inclination, angulation, and relative prominence were also similar. Hence, we concluded that tooth shape and position are constant for each tooth type. The data from this study were comparable with Andrews's findings. However, from this study, it would be safe to presume that all teeth except the maxillary second molars require alterations in the bracket base inclination value, and that the maxillary lateral incisor, canine, second premolar, and second molar, and the mandibular canine, require alterations in angulation values.

  11. Measurement of cerebral blood flow with two-dimensional cine phase-contrast MR imaging. Evaluation of normal subjects and patients with vertigo

    Energy Technology Data Exchange (ETDEWEB)

    Kashimada, Akio; Machida, Kikuo; Honda, Norinari; Mamiya, Toshio; Takahashi, Taku; Kamano, Tsuyoshi; Osada, Hisato [Saitama Medical School, Kawagoe (Japan). Saitama Medical Center

    1995-03-01

    The purpose of this study was to determine whether or not the vertebral flow of patients with vertigo and normal brain magnetic resonance (MR) images was decreased in comparison with normal controls. Cerebral blood flow (CBF) was quantitatively measured by a two-dimensional phase contrast cine MR imaging technique in 24 normal controls (mean age, 38.6 years; range, 12-70) and 23 patients (mean age, 53.7 years; range, 19-76) with a 1.5 Tesla MR imaging unit. Inter-and intraobserver variation in blood flow measurements was small (r=0.970, standard error of the estimate [SEE]=2.9 ml, n=80; r=0.963, SEE=4.6 ml, n=40, respectively), In the normal group, mean summed vertebral flow (171 ml/min, SD=40.6) was significantly less than mean summed carotid flow (523 ml/min, SD=111). Right vertebral flow (80.2 ml/min, SD=30.5) was less than left vertebral flow (91.2 ml/min, SD=38.2), but the difference was not statistically significant (p<0.05), In the 23 patients, although the summed vertebral flows of two patients (63.3, 88.8 ml/min) were significantly less than that of the normal group, mean summed vertebral flow (165 ml/min, SD=59.1) showed no significant difference from that of the normal group (p<0.05). In this study, the majority of patients had normal CBF. This method is clinically useful for estimating CBF. (author).

  12. Measurement of cerebral blood flow with two-dimensional cine phase-contrast MR imaging. Evaluation of normal subjects and patients with vertigo

    International Nuclear Information System (INIS)

    Kashimada, Akio; Machida, Kikuo; Honda, Norinari; Mamiya, Toshio; Takahashi, Taku; Kamano, Tsuyoshi; Osada, Hisato

    1995-01-01

    The purpose of this study was to determine whether or not the vertebral flow of patients with vertigo and normal brain magnetic resonance (MR) images was decreased in comparison with normal controls. Cerebral blood flow (CBF) was quantitatively measured by a two-dimensional phase contrast cine MR imaging technique in 24 normal controls (mean age, 38.6 years; range, 12-70) and 23 patients (mean age, 53.7 years; range, 19-76) with a 1.5 Tesla MR imaging unit. Inter-and intraobserver variation in blood flow measurements was small (r=0.970, standard error of the estimate [SEE]=2.9 ml, n=80; r=0.963, SEE=4.6 ml, n=40, respectively), In the normal group, mean summed vertebral flow (171 ml/min, SD=40.6) was significantly less than mean summed carotid flow (523 ml/min, SD=111). Right vertebral flow (80.2 ml/min, SD=30.5) was less than left vertebral flow (91.2 ml/min, SD=38.2), but the difference was not statistically significant (p<0.05), In the 23 patients, although the summed vertebral flows of two patients (63.3, 88.8 ml/min) were significantly less than that of the normal group, mean summed vertebral flow (165 ml/min, SD=59.1) showed no significant difference from that of the normal group (p<0.05). In this study, the majority of patients had normal CBF. This method is clinically useful for estimating CBF. (author)

  13. Meteoric water in normal fault systems: Oxygen and hydrogen isotopic measurements on authigenic phases in brittle fault rocks

    Science.gov (United States)

    Haines, S. H.; Anderson, R.; Mulch, A.; Solum, J. G.; Valley, J. W.; van der Pluijm, B. A.

    2009-12-01

    The nature of fluid circulation systems in normal fault systems is fundamental to understanding the nature of fluid movement within the upper crust, and has important implications for the on-going controversy about the strength of faults. Authigenic phases in clay gouges and fault breccias record the isotopic signature of the fluids they formed in equilibrium with, and can be used to understand the ‘plumbing system’ of brittle fault environments. We obtained paired oxygen and hydrogen isotopic measurements on authigenic illite and/or smectite in clay gouge from normal faults in two geologic environments, 1.) low-angle normal faults (Ruby Mountains detachment, NV; Badwater Turtleback, CA; Panamint range-front detachment; CA; Amargosa detachment; CA; Waterman Hills detachment, CA), and 2.) An intracratonic high-angle normal fault (Moab Fault, UT). All authigenic phases in these clay gouges are moderately light isotopically with respect to oxygen (illite δ18O -2.0 - + 11.5 ‰ SMOW, smectite δ18O +3.6 and 17.9 ‰) and very light isotopically with respect to hydrogen (illite δD -148 to -98 ‰ SMOW, smectite δD -147 to -92 ‰). Fluid compositions calculated from the authigenic clays at temperatures of 50 - 130 ○C (as indicated by clay mineralogy) indicate that both illite and smectite in normal fault clay gouge formed in the presence of near-pristine to moderately-evolved meteoric fluids and that igneous or metamorphic fluids are not involved in clay gouge formation in these normal fault settings. We also obtained paired oxygen and hydrogen isotopic measurements on chlorites derived from footwall chlorite breccias in 4 low-angle normal fault detachment systems (Badwater and Mormon Point Turtlebacks, CA, the Chemehuevi detachment, CA, and the Buckskin-Rawhide detachment, AZ). All chlorites are isotopically light to moderately light with respect to oxygen (δ18O +0.29 to +8.1 ‰ SMOW) and very light with respect to hydrogen (δD -97 to -113 ‰) and indicate

  14. Fission cross-section normalization problems

    International Nuclear Information System (INIS)

    Wagemans, C.; Ghent Rijksuniversiteit; Deruytter, A.J.

    1983-01-01

    The present measurements yield σsub(f)-data in the neutron energy from 20 MeV to 30 keV directly normalized in the thermal region. In the keV-region these data are consistent with the absolute σsub(f)-measurements of Szabo and Marquette. For the secondary normalization integral I 2 values have been obtained in agreement with those of Gwin et al. and Czirr et al. which were also directly normalized in the thermal region. For the I 1 integral, however, puzzling low values have been obtained. This was also the case for σsub(f)-bar in neutron energy intervals containing strong resonances. Three additional measurements are planned to further investigate these observations: (i) maintaining the actual approx.2π-geometry but using a 10 B-foil for the neutron flux detection (ii) using a low detection geometry with a 10 B- as well as a 6 Li-flux monitor. Only after these measurements definite conclusions on the I 1 and I 2 integrals can be formulated and final σsub(f)-bar-values can be released. The present study also gives some evidence for a correlation between the integral I 2 and the neutron flux monitor used. The influence of a normalization via I 1 or I 2 on the final cross-section has been shown. The magnitude of possible normalization errors is illustrated. Finally, since 235 U is expected to be an ''easy'' nucleus (low α-activity high σsub(f)-values), there are some indications that the important discrepancies still present in 235 U(n,f) cross-section measurements might partially be due to errors in the neutron flux determination

  15. Determination of molybdenum in various materials by normal-phase liquid chromatography using N-benzoyl-N-phenylhydroxylamine

    International Nuclear Information System (INIS)

    Bagur, Gracia; Sanchez-Vinas, Mercedes; Gazquez, Domingo

    1995-01-01

    A normal-phase liquid chromatographic method for the selective determination of molybdenum with N-benzoyl-N-phenylhydroxylamine is described. The molybdenum(VI) complex was preconcentrated by extraction into chloroform and injected onto a nitrile column for chromatography. The mobile phase was a 0.075 M solution of reagent in chloroform (stabilized with amylene). The detection limit for molybdenum by the proposed method was 0.88 ng for a phase volume ratio of 20:1 (aqueous to organic). Molybdenum has been determined in several samples with satisfactory accuracy and precision

  16. On combining multi-normalization and ancillary measures for the optimal score level fusion of fingerprint and voice biometrics

    Science.gov (United States)

    Mohammed Anzar, Sharafudeen Thaha; Sathidevi, Puthumangalathu Savithri

    2014-12-01

    In this paper, we have considered the utility of multi-normalization and ancillary measures, for the optimal score level fusion of fingerprint and voice biometrics. An efficient matching score preprocessing technique based on multi-normalization is employed for improving the performance of the multimodal system, under various noise conditions. Ancillary measures derived from the feature space and the score space are used in addition to the matching score vectors, for weighing the modalities, based on their relative degradation. Reliability (dispersion) and the separability (inter-/intra-class distance and d-prime statistics) measures under various noise conditions are estimated from the individual modalities, during the training/validation stage. The `best integration weights' are then computed by algebraically combining these measures using the weighted sum rule. The computed integration weights are then optimized against the recognition accuracy using techniques such as grid search, genetic algorithm and particle swarm optimization. The experimental results show that, the proposed biometric solution leads to considerable improvement in the recognition performance even under low signal-to-noise ratio (SNR) conditions and reduces the false acceptance rate (FAR) and false rejection rate (FRR), making the system useful for security as well as forensic applications.

  17. An ultrasonographic study on measurement of normal hip joint in Korean

    International Nuclear Information System (INIS)

    Lim, Hyo Keun; Choo, In Wook; Park, Soo Sung; Han, Man Chung

    1989-01-01

    The ultrasonography is very useful in evaluation of small amount of effusion in hip joint and has several advantages such as noninvasiveness, easiness, accuracy and no radiation hazard. The data of normal hip joint space and capsule is very important in ultrasonographic evaluation of inflammatory hip joint disease. However, normal ultrasonographic data of hip joint has not been reported except in pediatric age. The purpose of this study was to evaluate and measure normal hip joint space and capsule and to provide the basic data for the clinical application. Healthy 70 males and 70 females who have had no past history and present clinical symptom of hip joint were examined with real time sector scanner (5MHz transducer). Width of hip joint spaces and thickness of joint capsule were obtained and analysed by statistical analysis. The results were as follows: 1. The average width of the hip joint space were 2.6±0.5 mm (right), 2.5±0.5 mm (left) in males and 2.4±0.5 (right), 2.5±0.6 mm (left) in females. There was no significant difference by sex. 2. The widths of the hip joint space were increased with aging and decreased after 6th decade (male) and 5th decade (females). 3. The maximal difference of both hip joint space was 1.2 mm and there was no significant difference in both side by sex and age. 4. The average thicknesses of hip joint capsule were 1.9±0.3 mm (right), 1.8±0.2 mm (left) in males and 1.7±0.3 mm (right), 1.7±0.2 mm (left) in females. There was no significant difference by sex. 5. The thickness of the hip joint capsule were increased with aging and were in plateau after 5th decade (male and female). 6. The maximal difference of both hip joint capsules was 0.9 mm and there was no significant difference in both sides by sex and age. It is therefore, considered that ultrasonography could be a very useful modality in diagnosis of hip joint disease in which the hip joint space and the hip joint capsule are changed by various etiologies

  18. Measurements of the normal ventricles and cerebral cisterns of 100 adults with computed tomography

    International Nuclear Information System (INIS)

    Miyamoto, Kyoji

    1979-01-01

    The computed tomographical examinations of 100 patients with normal neurological findings including some volunteers between the ages of 20 to 68 years were evaluated. Measurements of various parts of the ventricular system on the polaroid pictures showed an increase with age and sexual difference. The lateral ventricles were found to be larger in the male in the female. Inverse cella media index, bifrontal cerebroventricular index and bicaudate cerebroventricular index were found to be reliable indicators of ventricular size, when the age and the sex is known. (author)

  19. Monitoring the normal body

    DEFF Research Database (Denmark)

    Nissen, Nina Konstantin; Holm, Lotte; Baarts, Charlotte

    2015-01-01

    of practices for monitoring their bodies based on different kinds of calculations of weight and body size, observations of body shape, and measurements of bodily firmness. Biometric measurements are familiar to them as are health authorities' recommendations. Despite not belonging to an extreme BMI category...... provides us with knowledge about how to prevent future overweight or obesity. This paper investigates body size ideals and monitoring practices among normal-weight and moderately overweight people. Methods : The study is based on in-depth interviews combined with observations. 24 participants were...... recruited by strategic sampling based on self-reported BMI 18.5-29.9 kg/m2 and socio-demographic factors. Inductive analysis was conducted. Results : Normal-weight and moderately overweight people have clear ideals for their body size. Despite being normal weight or close to this, they construct a variety...

  20. Hospital outpatients are satisfactory for case-control studies on cancer and diet in China: a comparison of population versus hospital controls.

    Science.gov (United States)

    Li, Lin; Zhang, Min; Holman, C D'Arcy J

    2013-01-01

    To investigate the internal validity of a food-frequency questionnaire (FFQ) developed for use in Chinese women and to compare habitual dietary intakes between population and hospital controls measured by the FFQ. A quantitative FFQ and a short food habit questionnaire (SFHQ) were developed and adapted for cancer and nutritional studies. Habitual dietary intakes were assessed in 814 Chinese women aged 18-81 years (407 outpatients and 407 population controls) by face-to-face interview using the FFQ in Shenyang, Northeast China in 2009-2010. The Goldberg formula (ratio of energy intake to basal metabolic rate, EI/BMR) was used to assess the validity of the FFQ. Correlation analyses compared the SFHQ variables with those of the quantitative FFQ. Differences in dietary intakes between hospital and population controls were investigated. Odds ratios (ORs) and 95% confidence intervals (CIs) were obtained using conditional logistic regression analyses. The partial correlation coefficients were moderate to high (0.42 to 0.80; all pcontrols were comparable to population controls in consumption of 17 measured food groups and mean daily intakes of energy and selected nutrients. The FFQ had reasonable validity to measure habitual dietary intakes of Chinese women. Hospital outpatients provide a satisfactory control group for food consumption and intakes of energy and nutrients measured by the FFQ in a Chinese hospital setting.

  1. Digital PIV Measurements of Acoustic Particle Displacements in a Normal Incidence Impedance Tube

    Science.gov (United States)

    Humphreys, William M., Jr.; Bartram, Scott M.; Parrott, Tony L.; Jones, Michael G.

    1998-01-01

    Acoustic particle displacements and velocities inside a normal incidence impedance tube have been successfully measured for a variety of pure tone sound fields using Digital Particle Image Velocimetry (DPIV). The DPIV system utilized two 600-mj Nd:YAG lasers to generate a double-pulsed light sheet synchronized with the sound field and used to illuminate a portion of the oscillatory flow inside the tube. A high resolution (1320 x 1035 pixel), 8-bit camera was used to capture double-exposed images of 2.7-micron hollow silicon dioxide tracer particles inside the tube. Classical spatial autocorrelation analysis techniques were used to ascertain the acoustic particle displacements and associated velocities for various sound field intensities and frequencies. The results show that particle displacements spanning a range of 1-60 microns can be measured for incident sound pressure levels of 100-130 dB and for frequencies spanning 500-1000 Hz. The ability to resolve 1 micron particle displacements at sound pressure levels in the 100 dB range allows the use of DPIV systems for measurement of sound fields at much lower sound pressure levels than had been previously possible. Representative impedance tube data as well as an uncertainty analysis for the measurements are presented.

  2. Networks of conforming or nonconforming individuals tend to reach satisfactory decisions.

    Science.gov (United States)

    Ramazi, Pouria; Riehl, James; Cao, Ming

    2016-11-15

    Binary decisions of agents coupled in networks can often be classified into two types: "coordination," where an agent takes an action if enough neighbors are using that action, as in the spread of social norms, innovations, and viral epidemics, and "anticoordination," where too many neighbors taking a particular action causes an agent to take the opposite action, as in traffic congestion, crowd dispersion, and division of labor. Both of these cases can be modeled using linear-threshold-based dynamics, and a fundamental question is whether the individuals in such networks are likely to reach decisions with which they are satisfied. We show that, in the coordination case, and perhaps more surprisingly, also in the anticoordination case, the agents will indeed always tend to reach satisfactory decisions, that is, the network will almost surely reach an equilibrium state. This holds for every network topology and every distribution of thresholds, for both asynchronous and partially synchronous decision-making updates. These results reveal that irregular network topology, population heterogeneity, and partial synchrony are not sufficient to cause cycles or nonconvergence in linear-threshold dynamics; rather, other factors such as imitation or the coexistence of coordinating and anticoordinating agents must play a role.

  3. Study on the measurement of serum thymidine kinase and its clinical significance in hematological neoplastic disorders

    Energy Technology Data Exchange (ETDEWEB)

    Torizumi, Kazutami; Aibata, Hirofumi; Yamada, Ryusaku; Shimizu, Eiji; Okamoto, Yukiharu; Tsujimoto, Masato; Tsuda, Tadaaki; Ota, Kiichiro

    1988-06-01

    A 'Prolifigen TK-REA' kit for measuring serum thymidine kinase (TK) was fundamentally and clinically evaluated. Laboratory findings for recovery, dilution, and reproducibility were satisfactory. There was no correlation between serum TK activity and serum lactic dehydrogenase, carcinoembryonic antigen, or ..cap alpha..-fetoprotein. The serum concentration of TK in normal volunteers ranged from 1.6 to 6.5 U/L. It was extremely high for chronic myeloid leukemia (CML) and acute myeloid leukemia (AML), as compared to the normal value. In the AML group, higher incidence of blasts in peripheral blood tended to be associated with higher serum concentration of TK. A similar tendency was seen in the case of acute lymphocytic leukemia (ALL) and myelodysplasia syndrome (MDS). A positive correlation between serum TK activity and the absolute counts of myeloblasts in peripheral blood existed in CML and AML patients. Since patients with hematological neoplastic disorders, who have abnormality in DNA metabolism, tended to have higher serum TK activity than did normal volunteers, serum TK activity may have a potential marker for abnormal DNA metabolism. (Namekawa, K.).

  4. Computation of a numerically satisfactory pair of solutions of the differential equation for conical functions of non-negative integer orders

    NARCIS (Netherlands)

    T.M. Dunster (Mark); A. Gil (Amparo); J. Segura (Javier); N.M. Temme (Nico)

    2014-01-01

    textabstractWe consider the problem of computing satisfactory pair of solutions of the differential equation for Legendre functions of non-negative integer order $\\mu$ and degree $-\\frac12+i\\tau$, where $\\tau$ is a non-negative real parameter. Solutions of this equation are the conical functions

  5. Shear wave velocity measurements using acoustic radiation force impulse in young children with normal kidneys versus hydronephrotic kidneys

    Directory of Open Access Journals (Sweden)

    Beomseok Sohn

    2014-04-01

    Conclusion: Obtaining ARFI measurements of the kidney is feasible in young children with median SWVs of 1.75 m/sec in normal kidneys. Median SWVs increased in high-grade hydronephrotic kidneys but were not different between hydronephrotic kidneys with and without UPJO.

  6. A Better Leveled Playing Field for Assessing Satisfactory Job Performance of Superintendents on the Basis of High-Stakes Testing Outcomes

    Science.gov (United States)

    Young, I. Phillip; Cox, Edward P.; Buckman, David G.

    2014-01-01

    To assess satisfactory job performance of superintendents on the basis of school districts' high-stakes testing outcomes, existing teacher models were reviewed and critiqued as potential options for retrofit. For these models, specific problems were identified relative to the choice of referent groups. An alternate referent group (statewide…

  7. Proximal Opening Wedge Osteotomy Provides Satisfactory Midterm Results With a Low Complication Rate.

    Science.gov (United States)

    Oravakangas, Rami; Leppilahti, Juhana; Laine, Vesa; Niinimäki, Tuukka

    2016-01-01

    Hallux valgus is one of the most common foot deformities. Proximal opening wedge osteotomy is used for the treatment of moderate and severe hallux valgus with metatarsus primus varus. However, hypermobility of the first tarsometatarsal joint can compromise the results of the operation, and a paucity of midterm results are available regarding proximal open wedge osteotomy surgery. The aim of the present study was to assess the midterm results of proximal open wedge osteotomy in a consecutive series of patients with severe hallux valgus. Thirty-one consecutive adult patients (35 feet) with severe hallux valgus underwent proximal open wedge osteotomy. Twenty patients (35.5%) and 23 feet (34.3%) were available for the final follow-up examination. The mean follow-up duration was 5.8 (range 4.6 to 7.0) years. The radiologic measurements and American Orthopaedic Foot and Ankle Society hallux-metatarsophalangeal-interphalangeal scores were recorded pre- and postoperatively, and subjective questionnaires were completed and foot scan analyses performed at the end of the follow-up period. The mean hallux valgus angle decreased from 38° to 23°, and the mean intermetatarsal angle correction decreased from 17° to 10°. The mean improvement in the American Orthopaedic Foot and Ankle Society hallux metatarsophalangeal-interphalangeal score increased from 52 to 84. Two feet (5.7%) required repeat surgery because of recurrent hallux valgus. No nonunions were identified. Proximal open wedge osteotomy provided satisfactory midterm results in the treatment of severe hallux valgus, with a low complication rate. The potential instability of the first tarsometatarsal joint does not seem to jeopardize the midterm results of the operation. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. C3–6 Laminoplasty for Cervical Spondylotic Myelopathy Maintains Satisfactory Long-Term Surgical Outcomes

    Science.gov (United States)

    Sakaura, Hironobu; Hosono, Noboru; Mukai, Yoshihiro; Iwasaki, Motoki; Yoshikawa, Hideki

    2014-01-01

    Study Design Prospective cohort study. Objective To clarify long-term surgical outcomes of C3–6 laminoplasty preserving muscles attached to the C2 and C7 spinous processes in patients with cervical spondylotic myelopathy (CSM). Methods Twenty patients who underwent C3–6 open-door laminoplasty for CSM and who were followed for 8 to 10 years were included in this study. Myelopathic symptoms were assessed using Japanese Orthopaedic Association (JOA) score. Axial neck pain was graded as severe, moderate, or mild. C2–7 angle was measured using lateral radiographs of the cervical spine before surgery and at final follow-up. Results Mean JOA score before surgery (11.7) was significantly improved to 15.2 at the time of maximum recovery (1 year after surgery), declining slightly to 14.9 by the latest follow-up. Late deterioration of JOA score developed in eight patients, but was unrelated to the cervical spine lesions in each case. No patient suffered from prolonged postoperative axial neck pain at final follow-up. The mean C2–7 angle before surgery (13.8 degrees) significantly increased to 19.2 degrees at final follow-up. Conclusions C3–6 laminoplasty preserving muscles attached to the C2 and C7 spinous processes in patients with CSM maintained satisfactory long-term neurologic improvement with significantly reduced frequencies of prolonged postoperative axial neck pain and loss of C2–7 angle after surgery. PMID:25083358

  9. Precaval retropancreatic space: Normal anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yeon Hee; Kim, Ki Whang; Kim, Myung Jin; Yoo, Hyung Sik; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1992-07-15

    The authors defined precaval retropancreatic space as the space between pancreatic head with portal vein and IVC and analyzed the CT findings of this space to know the normal structures and size in this space. We evaluated 100 cases of normal abdominal CT scan to find out normal anatomic structures of precaval retropancreatic space retrospectively. We also measured the distance between these structures and calculated the minimum, maximum and mean values. At the splenoportal confluence level, normal structures between portal vein and IVC were vessel (21%), lymph node (19%), and caudate lobe of liver (2%) in order of frequency. The maximum AP diameter of portocaval lymph node was 4 mm. Common bile duct (CBD) was seen in 44% and the diameter was mean 3 mm and maximum 11 mm. CBD was located in extrapancreatic (75%) and lateral (60.6%) to pancreatic head. At IVC-left renal vein level, the maximum distance between CBD and IVC was 5 mm and the structure between posterior pancreatic surface and IVC was only fat tissue. Knowledge of these normal structures and measurement will be helpful in differentiating pancreatic mass with retropancreatic mass such as lymphadenopathy.

  10. Diffractive optical element-based glossmeter for the on-line measurement of normal reflectance on a printed porous coated paper

    Science.gov (United States)

    Oksman, Antti; Kuivalainen, Kalle; Ta˚G, Carl-Mikael; Juuti, Mikko; Mattila, Rauno; Hietala, Eero; Gane, Patrick A. C.; Peiponen, Kai-Erik

    2011-04-01

    Gloss of a product, such as print gloss, is mainly inspected with conventional white light glossmeters both at laboratory or production facilities. However, problems occur in conventional gloss measurement when the inspected surface is vertically moved in the plane of incidence and reflection or when the measurement area is small or curved. For a partial solution to these problems, we have previously introduced diffractive optical element-based glossmeters (DOGs) for the gloss inspection in laboratories and off-line use. We present a new construction of DOG, termed μDOG 1D, for the one-dimensional on-line print gloss measurement, in the form of the reflectance determination normal to the surface. The function of the glossmeter is demonstrated by laboratory tests and on-line measurements at a heat-set web offset printing machine. It is shown that gloss (i.e., normal reflectance) and minute gloss variation of papers and prints can be measured at the printing line using the glossmeter. This glossmeter is expected to be useful in real-time monitoring of the gloss and surface-specific absorption not only in the printing industry but also in inspection of products in other industrial sectors, such as metal finishing, laminating, paper, and construction materials manufacturing.

  11. Cortical Thinning in Network-Associated Regions in Cognitively Normal and Below-Normal Range Schizophrenia

    Directory of Open Access Journals (Sweden)

    R. Walter Heinrichs

    2017-01-01

    Full Text Available This study assessed whether cortical thickness across the brain and regionally in terms of the default mode, salience, and central executive networks differentiates schizophrenia patients and healthy controls with normal range or below-normal range cognitive performance. Cognitive normality was defined using the MATRICS Consensus Cognitive Battery (MCCB composite score (T=50 ± 10 and structural magnetic resonance imaging was used to generate cortical thickness data. Whole brain analysis revealed that cognitively normal range controls (n=39 had greater cortical thickness than both cognitively normal (n=17 and below-normal range (n=49 patients. Cognitively normal controls also demonstrated greater thickness than patients in regions associated with the default mode and salience, but not central executive networks. No differences on any thickness measure were found between cognitively normal range and below-normal range controls (n=24 or between cognitively normal and below-normal range patients. In addition, structural covariance between network regions was high and similar across subgroups. Positive and negative symptom severity did not correlate with thickness values. Cortical thinning across the brain and regionally in relation to the default and salience networks may index shared aspects of the psychotic psychopathology that defines schizophrenia with no relation to cognitive impairment.

  12. High-resolution magnetic resonance imaging of the wrist: Normal anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Baker, L.L.; Hajek, P.C.; Bjoerkengren, A.; Sartoris, D.J.; Resnick, D.; Galbraith, R.; Gelberman, R.H.

    1987-02-01

    Magnetic resonance imaging (MRI) provided adequate depiction of carpal soft tissue structures in normal volunteers, as well as accurate anatomic correlation with cadaveric specimens. Using a high field strength system and surface coil techniques, the intricate anatomy of the wrist was best defined on long TR short TE images. However, from a practical view, T1 weighted images (TR 600 ms, TE 25 ms) were most useful because of short imaging times, satisfactory image quality, and the absence of motion artifacts. The coronal plane provided the clearest definition of important structures. Potential diagnostic limitations exist due to the inability of MRI to clearly delineate articular cartilage, joint capsules, and small interosseous ligaments. The presence of intra-articular fluid in both living subjects and cadaveric specimens, however, allowed for fine depiction of these structures on T2 weighted images.

  13. NORMAL PRESSURE AND FRICTION STRESS MEASUREMENT IN ROLLING PROCESSES

    DEFF Research Database (Denmark)

    Henningsen, Poul; Arentoft, Mogens; Lagergren, Jonas

    2005-01-01

    the output from the transducer, the friction stress and normal pressure in the contact zone can be determined. The new concept differs from existing pin designs by a lower disturbance of lubricant film and material flow and limited penetration of material between transducer and roll. Aluminum, cupper...

  14. Normal measurement of spinal cord and dural sac by CT myelography

    International Nuclear Information System (INIS)

    Yun, Ku Sub; Choi, Yo Won; Han, Moon Hee; Chang, Kee Hyun

    1988-01-01

    The data on the normal measurement of spinal cord are essential for an objective assessment of equivocal change of spinal cord size in the various clinical settings. The present study was therefore undertaken to evaluate normal range of spinal cord dimensions in Koreas. CT myelography of the cervical and thoracic region was performed in 60 patients who had symptoms referable to lumbosacral region and then computed tomographic measurement of spinal cord and dural sac was performed. The results are as follows: 1. The anteroposterior diameter of spinal cord was maximum at C1 level (8.6±1.4mm) and minimum at T6 level (6.4±1.7mm). 2. The transverse diameter of spinal cord was maximum at C4 and C5 levels (13.3±1.6mm) and minimum at T8 (8.1±1.9mm) and T10 (8.1±1.3mm) levels. 3. The area of spinal cord was maximum at C5 level (76±16mm 2 ) and minimum at T6 (40±24mm 2 ) and T8 (40±23mm 2 ) levels. 4. The ratio of anteroposterior diameter/transverse diameter of spinal cord was smallest at C4 (0.57±0.11) and C5 (0.57±0.09) levels and largest at T12 (0.9±0.17) level. 5. The ratio of anteroposterior diameter of spinal cord/dural sac was maximum at C4 level (0.73±0.14) and minimum at T12 level (0.52±0.15). The ratio of transverse diameter of spinal cord/dural sac was maximum at C3 (0.66±0.10) and C4 (0.66±0.14) levels and minimum at T12 level (0.46±0.18). The ratio of area of spinal cord/dural sac was maximum at C3 level (0.48±0.13) and minimum at T12 level (0.29±0.20). 6. The location of cervical cord in dural sac was mainly ventral (56%) at C1 level, middle (40-73%) from C2 to C6 level and dorsal (44%) at C7 level. The location of thoracic cord in dural sac was chiefly middle (61%) at T2 level and lower thoracic level (T10: 60% and T12: 51%) and mainly ventral (59-84%) at other levels.

  15. Measurement of normal intracranial artery diameter using three-dimensional reconstruction rotational angiogram

    International Nuclear Information System (INIS)

    Kwon, Bae Ju; Han, Moon Hee; Go, Joong Seok; Chang, Kee Hyun; Lee, Seung Rho; Hahm, Chang Kok

    2004-01-01

    To evaluate the distribution of normal intracranial artery diameter according to sex and age, using three-dimensional reconstruction rotational angiography. One hundred and twenty-five adults with normal intracranial arteries who underwent 3D rotational angiography (n=177) were included in this study. The arterial diameter was measured at four sites of the internal carotid artery (cavernous, paraophthalmic, supraclinoid, and distal), that of the middle cerebral artery at two (proximal and distal), and that of the anterior cerebral artery at one (middle). For each sex and age group (<30, 30-39, 40-49, 50-59, ≥ 60 years), the mean diameter of the artery at these seven sites was calculated, and differences analysed. In addition, the middle cerebral artery diameter was compared between a younger group (<50 years) and an older group (≥ 50 years). The mean diameter at each site for each sex was as follows: male (mean±SD): 4.61±0.69, 3.96±0.60, 3.48±0.45, 3.61±0.50, 2.44±0.32, 2.44±0.37, 1.81±0.32; female : 4.29±0.57, 3.83±0.56, 3.37±0.56, 3.52±0.48, 2.32±0.37, 2.30±0.36, 1.76±0.34. For those in their 40s, the diameter at five sites (all four sites of the internal cerebral artery and a distal middle cerebral artery) was significantly greater in males than in females. For other age groups, however, the difference between the sexes was absent, or was significant at only one (cavernous internal cerebral artery for those in their 30s) or two (proximal and distal middle cerebral artery was 2.59±0.35 mm in males and 2.38±0.37 mm in females. For the distal middle cerebral artery, the corresponding figures were 2.63±0.43 and 2.39±0.35 mm, respectively. For both sexes, the differences between the two age groups were significant. For those in their 40, the normal diameter of the intracranial artery at most arterial sites was significantly greater in males than in females. The normal diameter of the middle cerebral artery was significantly greater or tended to

  16. Virtual planning of complex head and neck reconstruction results in satisfactory match between real outcomes and virtual models.

    Science.gov (United States)

    Hanken, Henning; Schablowsky, Clemens; Smeets, Ralf; Heiland, Max; Sehner, Susanne; Riecke, Björn; Nourwali, Ibrahim; Vorwig, Oliver; Gröbe, Alexander; Al-Dam, Ahmed

    2015-04-01

    The reconstruction of large facial bony defects using microvascular transplants requires extensive surgery to achieve full rehabilitation of form and function. The purpose of this study is to measure the agreement between virtual plans and the actual results of maxillofacial reconstruction. This retrospective cohort study included 30 subjects receiving maxillofacial reconstruction with a preoperative virtual planning. Parameters including defect size, position, angle and volume of the transplanted segments were compared between the virtual plan and the real outcome using paired t test. A total of 63 bone segments were transplanted. The mean differences between the virtual planning and the postoperative situation were for the defect sizes 1.17 mm (95 % confidence interval (CI) (-.21 to 2.56 mm); p = 0.094), for the resection planes 1.69 mm (95 % CI (1.26-2.11); p = 0.033) and 10.16° (95 % CI (8.36°-11.96°); p satisfactory postoperative results are the basis for an optimal functional and aesthetic reconstruction in a single surgical procedure. The technique should be further investigated in larger study populations and should be further improved.

  17. Normal LVEF measurements are significantly higher in females asassessed by post-stress resting Tc-99m sestamibi gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Kim, Jong Ho; Shin, Eak Kyun

    1999-01-01

    Volume-LVEF relationship is one of the most important factors of automatic EF quantification algorithm from gated myocardial perfusion SPECT(gMPS) (Germano et al. JNM, 1995). Gender difference whereby normal LVEF measurements are higher in females assessed by gMPS (Yao et al. JNM 1997). To validate true physiologic value of LVEF vs sampling or measured error, various parameters were evaluated statistically in both gender and age matched 200 subjects (mean age= 58.41±15.01) with normal LVEF more than 50%, and a low likelihood of coronary artery disease. Correlation between LVEDVi(ml/m2) and LVEF was highly significant (r=-0.62, p<0.0001) with similar correlations noted in both male (r=-0.45, p<0.0001) and female (r=-0.67, p<0.0001) subgroups. By multivariate analysis, LV volume and stroke volume was the most significant factor influencing LVEF in male and female, respectively. In conclusion, there is a significant negative correlation between LV volume and LVEF as measured by Tc-99m gated SPECT. Higher normal LVEF value should be applied to females as assessed by post-stress resting Tc-99m Sestamibi gated myocardial perfusion SPECT

  18. Comparison of the corrosion potential for stainless steel measured in-plant and in laboratory during BWR normal water chemistry conditions

    International Nuclear Information System (INIS)

    Molander, A.; Pein, K.; Tarkpea, P.; Takagi, Junichi; Karlberg, G.; Gott, K.

    1998-01-01

    To obtain reliable crack growth rate date for stainless steel in BWR environments careful laboratory simulation of the environmental conditions is necessary. In the plant the BWR normal water chemistry environment contains hydrogen peroxide, oxygen and hydrogen. However, in crack growth rate experiments in laboratories, the environment is normally simulated by adding 200 ppb oxygen to the high temperature water. Thus, as hydrogen peroxide is a more powerful oxidant than oxygen, it is to be expected that a lower corrosion potential will be measured in the laboratory than in the plant. To resolve this issue this work has been performed. In-plant and laboratory measurements have often been performed with somewhat different equipment, due to the special requirements concerning in-plant measurements. In this work such differences have been avoided and two identical sets of equipment for electrochemical measurements were built and used for measurements in-plant in a Swedish BWR and in high purity water in the laboratory. The host plant was Barsebaeck 1. Corrosion potential monitoring in-plant was performed under both NWC (Normal Water Chemistry) and HWC (Hydrogen Water Chemistry) conditions. This paper is, however, focused on NWC conditions. This is due to the fact, that the total crack growth obtained during a reactor cycle, can be determined by NWC conditions, even for plants running with HWC due to periodic stops in the hydrogen addition for turbine inspections or failure of the dosage or hydrogen production equipment. Thus, crack growth data for NWC is of great importance both for BWRs operating with HWC and NWC. Measurements in-plant and in the laboratory were performed during additions of oxygen and hydrogen peroxide to the autoclave systems. The corrosion potentials were compared for various conditions in the autoclaves, as well as versus in-plant in-pipe corrosion potentials. (J.P.N.)

  19. Experimental measurement of flexion-extension movement in normal and corpse prosthetic elbow joint.

    Science.gov (United States)

    TarniŢă, Daniela; TarniŢă, DănuŢ Nicolae

    2016-01-01

    This paper presents a comparative experimental study of flexion-extension movement in healthy elbow and in the prosthetic elbow joint fixed on an original experimental bench. Measurements were carried out in order to validate the functional morphology and a new elbow prosthesis type ball head. The three-dimensional (3D) model and the physical prototype of our experimental bench used to test elbow endoprosthesis at flexion-extension and pronation-supination movements is presented. The measurements were carried out on a group of nine healthy subjects and on the prosthetic corpse elbow, the experimental data being obtained for flexion-extension movement cycles. Experimental data for the two different flexion-extension tests for the nine subjects and for the corpse prosthetic elbow were acquired using SimiMotion video system. Experimental data were processed statistically. The corresponding graphs were obtained for all subjects in the experimental group, and for corpse prosthetic elbow for both flexion-extension tests. The statistical analysis has proved that the flexion angles of healthy elbows were significantly close to the values measured at the prosthetic elbow fixed on the experimental bench. The studied elbow prosthesis manages to re-establish the mobility for the elbow joint as close to the normal one.

  20. The measurement of 99mTc-DTPA pulmonary clearance in normals, asymptomatic smokers and diabetic patients

    International Nuclear Information System (INIS)

    Kim, In Ju; Kim, Seong Jang; Kim, Yong Ki; Kim, Yun Seong; Lee, Min Ki; Park, Soon Kew

    1998-01-01

    We measured pulmonary epithelial permeability by 99m Tc-DTPA radioaerosol clearance in patients with diabetes and correlated with the presence of microangiopathy to understand the pathophysiology of pulmonary microangiopathy and evaluate 99m Tc-DTPA radioaerosol clearance as a diagnostic test to assess pulmonary microangiopathy. We performed 99m Tc-DTPA radioaerosol scan in 10 normal subjects, 10 asymptomatic smokers, 20 diabetic patients without history of smoking (10 with microangiopathy, 10 without microangiopathy). 99m Tc-DTPA clearance half-time (T 1/2 ) was calculated, then compared with the result of chest radiography and pulmonary function test. Chest radiography and pulmonary function test were normal in all subjects. There were no significant difference of clinical or laboratory characteristics between these groups except age. The diabetic patients with microangiophaty were significantly older (p 1/2 of normal subjects and asymptomatic smokers were significantly different (65.2±23.7 min vs 39.6±9.8 min, p 1/2 was 90.5±46.5 min and significantly delayed when compared with those of normals and asymptomatic smokers (p 1/2 of diabetic patients without microangiopathy, 70.0±12.7 min, was not significantly different from those of normals or asymptomatic smokers (p>0.05). No significant correlation was found between the T 1/2 and spirometric parameters including DLco, FVC, FEV 1 , FEV 1 /FVC (%) and FEF 25-75% in all subjects, and between the T 1/2 and duration of diabetes in diabetic patients. Eventhough the influence of age can't be excluded, delayed 99m Tc-DTPA clearance half-time (T 1/2 ) in diabetic patients with microangiopathy indicates decreased pulmonary capillary permeability as one of the pathophysiologic results of pulmonary microangiopaththy. Further studies are needed in larger number of age matched control and diabetic patients to evaluate the diagnostic efficacy

  1. Corneal thickness and elevation measurements using swept-source optical coherence tomography and slit scanning topography in normal and keratoconic eyes.

    Science.gov (United States)

    Jhanji, Vishal; Yang, Bingzhi; Yu, Marco; Ye, Cong; Leung, Christopher K S

    2013-11-01

    To compare corneal thickness and corneal elevation using swept source optical coherence tomography and slit scanning topography. Prospective study. 41 normal and 46 keratoconus subjects. All eyes were imaged using swept source optical coherence tomography and slit scanning tomography during the same visit. Mean corneal thickness and best-fit sphere measurements were compared between the instruments. Agreement of measurements between swept source optical coherence tomography and scanning slit topography was analyzed. Intra-rater reproducibility coefficient and intraclass correlation coefficient were evaluated. In normal eyes, central corneal thickness measured by swept source optical coherence tomography was thinner compared with slit scanning topography (p topography. In keratoconus eyes, central corneal thickness was thinner on swept source optical coherence tomography than slit scanning topography (p = 0.081) and ultrasound pachymetry (p = 0.001). There were significant differences between thinnest corneal thickness, and, anterior and posterior best-fit sphere measurements between both instruments (p topography. With better reproducibility coefficients and intraclass correlation coefficients, swept source optical coherence tomography may provide a reliable alternative for measurement of corneal parameters. © 2013 The Authors. Clinical and Experimental Ophthalmology © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  2. Right thoracic curvature in the normal spine

    Directory of Open Access Journals (Sweden)

    Masuda Keigo

    2011-01-01

    Full Text Available Abstract Background Trunk asymmetry and vertebral rotation, at times observed in the normal spine, resemble the characteristics of adolescent idiopathic scoliosis (AIS. Right thoracic curvature has also been reported in the normal spine. If it is determined that the features of right thoracic side curvature in the normal spine are the same as those observed in AIS, these findings might provide a basis for elucidating the etiology of this condition. For this reason, we investigated right thoracic curvature in the normal spine. Methods For normal spinal measurements, 1,200 patients who underwent a posteroanterior chest radiographs were evaluated. These consisted of 400 children (ages 4-9, 400 adolescents (ages 10-19 and 400 adults (ages 20-29, with each group comprised of both genders. The exclusion criteria were obvious chest and spinal diseases. As side curvature is minimal in normal spines and the range at which curvature is measured is difficult to ascertain, first the typical curvature range in scoliosis patients was determined and then the Cobb angle in normal spines was measured using the same range as the scoliosis curve, from T5 to T12. Right thoracic curvature was given a positive value. The curve pattern was organized in each collective three groups: neutral (from -1 degree to 1 degree, right (> +1 degree, and left ( Results In child group, Cobb angle in left was 120, in neutral was 125 and in right was 155. In adolescent group, Cobb angle in left was 70, in neutral was 114 and in right was 216. In adult group, Cobb angle in left was 46, in neutral was 102 and in right was 252. The curvature pattern shifts to the right side in the adolescent group (p Conclusions Based on standing chest radiographic measurements, a right thoracic curvature was observed in normal spines after adolescence.

  3. Reproducibility of measurements and variability of the classification algorithm of Stratus OCT in normal, hypertensive, and glaucomatous patients

    Directory of Open Access Journals (Sweden)

    Alfonso Antón

    2009-01-01

    Full Text Available Alfonso Antón1,2,3, Marta Castany1,2, Marta Pazos-Lopez1,2, Ruben Cuadrado3, Ana Flores3, Miguel Castilla11Hospital de la Esperanza-Hospital del Mar (IMAS, Barcelona, Spain; 2Institut Català de la Retina (ICR, Barcelona, Spain. Glaucoma Department; 3Instituto Universitario de Oftalmobiología Aplicada (IOBA, Universidad de Valladolid, Valladolid, EspañaPurpose: To assess the reproducibility of retinal nerve fiber layer (RNFL measurements and the variability of the probabilistic classification algorithm in normal, hypertensive and glaucomatous eyes using Stratus optical coherence tomography (OCT.Methods: Forty-nine eyes (13 normal, 17 ocular hypertensive [OHT] and 19 glaucomatous of 49 subjects were included in this study. RNFL was determined with Stratus OCT using the standard protocol RNFL thickness 3.4. Three different images of each eye were taken consecutively during the same session. To evaluate OCT reproducibility, coefficient of variation (COV and intraclass correlation coefficient (ICC were calculated for average thickness (AvgT, superior average thickness (Savg, and inferior average thickness (Iavg parameters. The variability of the results of the probabilistic classification algorithm, based on the OCT normative database, was also analyzed. The percentage of eyes with changes in the category assigned was calculated for each group.Results: The 50th percentile of COV was 2.96%, 4.00%, and 4.31% for AvgT, Savg, and Iavg, respectively. Glaucoma group presented the largest COV for all three parameters (3.87%, 5.55%, 7.82%. ICC were greater than 0.75 for almost all measures (except from the inferior thickness parameter in the normal group; ICC = 0.64, 95% CI 0.334–0.857. Regarding the probabilistic classification algorithm for the three parameters (AvgT, Savg, Iavg, the percentage of eyes without color-code category changes among the three images was as follows: normal group, 100%, 84.6% and 92%; OHT group, 89.5%, 52.7%, 79%; and

  4. Thickness Measurement of a Film on a Substrate by Low-Frequency Ultrasound

    Institute of Scientific and Technical Information of China (English)

    LI Ming-Xuan; WANG Xiao-Min; MAO Jie

    2004-01-01

    @@ We describe a new simple technique for the low-frequency ultrasonic thickness measurement of an air-backed soft thin layer attached on a hard substrate of finite thickness through the frequency-shifts of the substrate resonances by the substrate-side insonification. A plane compressive wave impinging normally on the substrate surface from a liquid is studied. Low frequency here means an interrogating acoustical wave frequency of less than half of coating to the substrate. Equations for the frequency-shifts are derived and solved by the Newton iterative method and the Taylor expansion method, respectively, indicating satisfactory agreement within the range of interest of thickness ratio of the thin layer to the substrate for a polymer-aluminium structure. An experimental setup is constructed to verify the validity of the technique.

  5. Endometrial blood flow measured by xenon 133 clearance in women with normal menstrual cycles and dysfunctional uterine bleeding

    International Nuclear Information System (INIS)

    Fraser, I.S.; McCarron, G.; Hutton, B.; Macey, D.

    1987-01-01

    Endometrial blood flow was measured through the menstrual cycle in nonpregnant women (28 studies of 17 women with normal menstrual cycles and 32 studies of 20 women with dysfunctional uterine bleeding) with use of a clearance technique in which 100 to 400 microCi of the gamma-emitting isotope, xenon 133 in saline solution was instilled into the uterine cavity. The mean (+/- SEM) endometrial blood flow in normal cycles was 27.7 +/- 2.6 ml/100 gm/min, with a significant elevation in the middle to late follicular phase, followed by a substantial fall and a secondary slow luteal phase rise that was maintained until the onset of menstruation. There was a significant correlation between plasma estradiol levels and endometrial blood flow in the follicular but not the luteal phase. Blood flow patterns in women with ovulatory dysfunctional bleeding were similar to normal, except for a significantly lower middle follicular rate. Women with anovulatory dysfunctional bleeding exhibited exceedingly variable flow rates

  6. Endometrial blood flow measured by xenon 133 clearance in women with normal menstrual cycles and dysfunctional uterine bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Fraser, I.S.; McCarron, G.; Hutton, B.; Macey, D.

    1987-01-01

    Endometrial blood flow was measured through the menstrual cycle in nonpregnant women (28 studies of 17 women with normal menstrual cycles and 32 studies of 20 women with dysfunctional uterine bleeding) with use of a clearance technique in which 100 to 400 microCi of the gamma-emitting isotope, xenon 133 in saline solution was instilled into the uterine cavity. The mean (+/- SEM) endometrial blood flow in normal cycles was 27.7 +/- 2.6 ml/100 gm/min, with a significant elevation in the middle to late follicular phase, followed by a substantial fall and a secondary slow luteal phase rise that was maintained until the onset of menstruation. There was a significant correlation between plasma estradiol levels and endometrial blood flow in the follicular but not the luteal phase. Blood flow patterns in women with ovulatory dysfunctional bleeding were similar to normal, except for a significantly lower middle follicular rate. Women with anovulatory dysfunctional bleeding exhibited exceedingly variable flow rates.

  7. Why is Housing Always Satisfactory? A Study into the Impact of Preference and Experience on Housing Appreciation.

    Science.gov (United States)

    Jansen, Sylvia J T

    2013-01-01

    This study focuses on residents' perceptions of residential quality concerning 23 different dwelling aspects. Respondents were asked to indicate their appreciation of these dwelling aspects on a scale ranging from 0 ("extremely unattractive") to 100 ("extremely attractive"). The influence of two potential factors on the appreciation of dwelling aspects is examined: (1) preference and (2) experience. It was hypothesized that residents who live according to their preferences give higher appreciation scores than residents who do not. This should even apply to low-quality housing. Furthermore, it was argued that residents appreciate their current housing situation more than residents who do not live in that particular housing situation. This effect should be independent of preference. The impact of both preference and of experience could be confirmed. The results also showed an interaction effect between preference and experience: the positive effect of experience on appreciation is larger in residents who live in a housing situation that they do not prefer. This result would be expected if the impact of experience works to decrease the 'gap' in residential satisfaction due to the discrepancy between what residents have and what they want. In conclusion, why is housing always satisfactory? In this paper, housing is satisfactory because the 'gap' between what residents want and what they have is small; residents seem to have realistic aspirations. Furthermore, residents appreciate what they already have, even if this is not what they prefer.

  8. Fundamental evaluation of bone densitometry using dual energy X-ray absorptiometry (DEXA)

    Energy Technology Data Exchange (ETDEWEB)

    Koizumi, Kiyoshi; Uchiyama, Guio; Araki, Tsutomu (Yamanashi Medical Coll., Tamaho (Japan)) (and others)

    1990-02-01

    A newly developed instrument based on dual energy X-ray absorptiometry (DEXA), Hologic QDR-1000, was evaluated fundamentally and clinically. Image quality was quite satisfactory though radiation exposure was minimal, 780.2 nC/kg (3.024 mR) for lumbar measurement. Reproducibility of the repeated measurement of a phantom was fairly good; 0.343 CV% in a same day and 0.520 CV% in a long period. Accuracy determined by measurement of potassium phosphate solution was also satisfactory. Bone mineral densities measured by this instrument were fairly correlated with those measured by single energy quantitative CT; coefficient was 0.740 for 17 patients. Mix-DP plates of more than 10 cm thick overestimated the bone mineral densities of a phantom. Bone mineral densities of Japanese normal volunteers were in the normal range (mean {plus minus} 2SD) of the Americans though mostly lower than the mean. In patients with spondylosis deformans or prominent aortic calcification, bone mineral densities might be overestimated. Lateral view was obtainable though its reproducibility was not good. Positioning especially for measuring femoral neck was quite critical for reproducible measurement. In conclusion, this new instrument is quite accurate and satisfactory for clinical application to measuring bone mineral densities. (author).

  9. Fundamental evaluation of bone densitometry using dual energy X-ray absorptiometry (DEXA)

    International Nuclear Information System (INIS)

    Koizumi, Kiyoshi; Uchiyama, Guio; Araki, Tsutomu

    1990-01-01

    A newly developed instrument based on dual energy X-ray absorptiometry (DEXA), Hologic QDR-1000, was evaluated fundamentally and clinically. Image quality was quite satisfactory though radiation exposure was minimal, 780.2 nC/kg (3.024 mR) for lumbar measurement. Reproducibility of the repeated measurement of a phantom was fairly good; 0.343 CV% in a same day and 0.520 CV% in a long period. Accuracy determined by measurement of potassium phosphate solution was also satisfactory. Bone mineral densities measured by this instrument were fairly correlated with those measured by single energy quantitative CT; coefficient was 0.740 for 17 patients. Mix-DP plates of more than 10 cm thick overestimated the bone mineral densities of a phantom. Bone mineral densities of Japanese normal volunteers were in the normal range (mean ± 2SD) of the Americans though mostly lower than the mean. In patients with spondylosis deformans or prominent aortic calcification, bone mineral densities might be overestimated. Lateral view was obtainable though its reproducibility was not good. Positioning especially for measuring femoral neck was quite critical for reproducible measurement. In conclusion, this new instrument is quite accurate and satisfactory for clinical application to measuring bone mineral densities. (author)

  10. Skin perfusion measurement: the normal range, the effects of ambient temperature and its clinical application

    International Nuclear Information System (INIS)

    Henry, R.E.; Malone, J.M.; Daly, M.J.; Hughes, J.H.; Moore, W.S.

    1982-01-01

    Quantitation of skin perfusion provides objective criteria to determine the optimal amputation level in ischemic limb disease, to assess the maturation of pedicle flaps in reconstructive surgery, and to select appropriate treatment for chronic skin ulcers. A technique for measurement of skin perfusion using intradermal (ID) Xe-133 and a gamma camera/minicomputer system was previously reported. An update of this procedure is now reported, the normal range for the lower extremity in men, observations on the effects of ambient temperature, and an experience using the procedure to determine amputation level

  11. Evaluation of moving-coil loudspeaker and passive radiator parameters using normal-incidence sound transmission measurements: theoretical developments.

    Science.gov (United States)

    Leishman, Timothy W; Anderson, Brian E

    2013-07-01

    The parameters of moving-coil loudspeaker drivers are typically determined using direct electrical excitation and measurement. However, as electro-mechano-acoustical devices, their parameters should also follow from suitable mechanical or acoustical evaluations. This paper presents the theory of an acoustical method of excitation and measurement using normal-incidence sound transmission through a baffled driver as a plane-wave tube partition. Analogous circuits enable key parameters to be extracted from measurement results in terms of open and closed-circuit driver conditions. Associated tools are presented that facilitate adjacent field decompositions and derivations of sound transmission coefficients (in terms of driver parameters) directly from the circuits. The paper also clarifies the impact of nonanechoic receiving tube terminations and the specific benefits of downstream field decompositions.

  12. Sense of coherence, self-esteem, and health locus of control in subjects with type 1 diabetes mellitus with/without satisfactory metabolic control.

    Science.gov (United States)

    Nuccitelli, C; Valentini, A; Caletti, M T; Caselli, C; Mazzella, N; Forlani, G; Marchesini, G

    2018-03-01

    Despite intensive training, a few individuals with Type 1 diabetes mellitus (T1DM) fail to reach the desired metabolic targets. To evaluate the association between disease-related emotional and cognitive aspects and metabolic control in subjects with T1DM. Health locus of control (HLOC), sense of coherence (SOC), and self-esteem were assessed in T1DM subjects using validated questionnaires. Sixty-seven consecutive subjects who did not attain the desired HbA1c target (mean HbA1c, 8.3% [67 mmol/mol]) were compared with 30 cases in satisfactory metabolic control (HbA1c levels satisfactory metabolic control tend to rely on significant others, trusting in the physicians' skills or on the efficiency of the health-care system. Strategies aimed at increasing self-efficacy and SOC, based on personal ability, are eagerly awaited to help patients improve diabetes care.

  13. Normalization of energy-dependent gamma survey data.

    Science.gov (United States)

    Whicker, Randy; Chambers, Douglas

    2015-05-01

    Instruments and methods for normalization of energy-dependent gamma radiation survey data to a less energy-dependent basis of measurement are evaluated based on relevant field data collected at 15 different sites across the western United States along with a site in Mongolia. Normalization performance is assessed relative to measurements with a high-pressure ionization chamber (HPIC) due to its "flat" energy response and accurate measurement of the true exposure rate from both cosmic and terrestrial radiation. While analytically ideal for normalization applications, cost and practicality disadvantages have increased demand for alternatives to the HPIC. Regression analysis on paired measurements between energy-dependent sodium iodide (NaI) scintillation detectors (5-cm by 5-cm crystal dimensions) and the HPIC revealed highly consistent relationships among sites not previously impacted by radiological contamination (natural sites). A resulting generalized data normalization factor based on the average sensitivity of NaI detectors to naturally occurring terrestrial radiation (0.56 nGy hHPIC per nGy hNaI), combined with the calculated site-specific estimate of cosmic radiation, produced reasonably accurate predictions of HPIC readings at natural sites. Normalization against two to potential alternative instruments (a tissue-equivalent plastic scintillator and energy-compensated NaI detector) did not perform better than the sensitivity adjustment approach at natural sites. Each approach produced unreliable estimates of HPIC readings at radiologically impacted sites, though normalization against the plastic scintillator or energy-compensated NaI detector can address incompatibilities between different energy-dependent instruments with respect to estimation of soil radionuclide levels. The appropriate data normalization method depends on the nature of the site, expected duration of the project, survey objectives, and considerations of cost and practicality.

  14. Patient's Perceptions Regarding Orthodontic Needs and Satisfactory Level with the Procedure.

    Science.gov (United States)

    Farishta, Saibel

    2015-09-01

    In order to keep the patients satisfied with Orthodontic treatment and to address the growing concern among new orthodontic patients, this study was undertaken to evaluate patient's perceptions of their orthodontic treatment needs and the satisfactory level with the procedure. This cross-sectional study was conducted among a sample of 362 patients who had received orthodontic treatment. Questionnaires included information factors that encouraged them to take orthodontic treatment, painful experience of orthodontic therapy, and also to know the effectiveness of the treatment. Student's t-test and ANOVA test were used to analyze results at P = 0.05. Most of the participants faced problems due to their dentition (60.2%), followed by mastication 23.6%. It was found that most of the study subjects were motivated by orthodontist to receive the treatment (29.7%). When the participants were asked about the complications faced by them during the procedure and the most common answer was a longer duration of the treatment (23.3%). Pain was also a common factor faced by the participants (15.9%). Significant results were seen according to gender and age. The study concluded that problems in the dentition were the main factor to seek orthodontic treatment and most of the subjects were convinced by the specialist to undergo orthodontic therapy. Many problems faced during the treatment, but still majority gave a positive response to the treatment.

  15. Bifactor model of WISC-IV: Applicability and measurement invariance in low and normal IQ groups.

    Science.gov (United States)

    Gomez, Rapson; Vance, Alasdair; Watson, Shaun

    2017-07-01

    This study examined the applicability and measurement invariance of the bifactor model of the 10 Wechsler Intelligence Scale for Children-Fourth Edition (WISC-IV) core subtests in groups of children and adolescents (age range from 6 to 16 years) with low (IQ ≤79; N = 229; % male = 75.9) and normal (IQ ≥80; N = 816; % male = 75.0) IQ scores. Results supported this model in both groups, and there was good support for measurement invariance for this model across these groups. For all participants together, the omega hierarchical and explained common variance (ECV) values were high for the general factor and low to negligible for the specific factors. Together, the findings favor the use of the Full Scale IQ (FSIQ) scores of the WISC-IV, but not the subscale index scores. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  16. Measurement of Placental Blood Flow with {sup 133}Xe in Normal and Pathological Human Pregnancy; Mesure du Debit Placentaire dans les Grossesses Normales et Pathologiques

    Energy Technology Data Exchange (ETDEWEB)

    Pontonnier, G.; Delmas, H.; Farre, J.; Favretto, R. [Clinique Obstetricale, Hopital de la Grave, Toulouse (France)

    1971-02-15

    Most authors agree that changes in placental circulation play an important part in the genesis of chronic foetal disorders. However, until recently there was no technique by which a quantitative evaluation of placental haemodynamics could be obtained. Our method of measuring placental blood flow represents one application of the use of radioisotopes for measurements of local blood flows. We use {sup 133}Xe in solution in physiological serum. This radioactive gas has the advantage of being inert and instantly diffusible. After radiographic or ultrasonic localization of the placenta, 50 {mu}Ci of xenon are injected into it transabdominally. A scintillation detector is used to take the {sup 133}Xe clearance curve, which is recorded simultaneously on a linear writer and transmitted to a computer. We have made 111 measurements of placental blood flow - 45 in normal pregnancy, 59 in pathological pregnancy and 7 after perfusion of medication. The measurements made it possible to obtain, for the first time, a quantitative evaluation of placental blood flow in women. The value found for normal pregnancies between the thirty-second and the forty-first weeks was 145 ml/100 g per min. The measurements carried out in pathologically pregnant patients (with arterial hypertension, dysgravidity, urinary infection, diabetes, prolonged pregnancy) showed that such pregnancies are accompanied by a statistically significant diminution of placental blood flow, and that the magnitude of this diminution has a bearing on the clinical condition and the state of the child at birth. This method of measurement, which is easily reproducible in the same patient, is accordingly of interest from two points of view. As far as theoretical studies are concerned, it has made possible a quantitative evaluation of placental blood flow and has supplied proof that the maternal disorders which give rise to chronic foetal disorders are usually accompanied by a diminution in placental blood flow. From the

  17. Normal CT measurement of sellar and juxtasellar structures

    International Nuclear Information System (INIS)

    Kim, Bo Hyun; Chung, Jin Wook; Han, Moon Hee; Chang, Kee Hyun

    1988-01-01

    The thorough knowledge of precise anatomy of the sellar, parasellar and suprasellar regions and of normal computed tomographic (CT) features in those areas are very important because there are many tiny but essential structures in which pathology makes only minute changes and so meticulous investigations are required. We performed direct coronal thin section CT scan of sellar and juxtasellar regions in 58 cases in order to evaluate normal CT features such as CT densities, shapes and sizes of normal sellar and juxtasellar structures. The results obtained are as follows: 1.The CT densities of pituitary glands were 87 ± 23 in anterior lobe and 69 ± 22 in posterior lobe. The latter was significantly less dense than the former. Posterior lobes could be identified as oval low density area in sagittal reconstruction in 18/58 (31%). Mean pituitary height was 6.5 ± 1.5mm. In young females of childbearing age, mean height was 7.0 ± 1.7mm. Upper margins of pituitary glands were flat in 29 cases (50%), upward convex in 16 cases (28%), and upward concave in 13 cases (22%). Upper margins of pituitary glands were upward convex in 8/15 (53%) of young female of childbearing age. Pituitary densities were homogeneous in 36 cases (77%) and heterogeneous in 7 cases (15%), and 4 cases (7%) show focal pituitary low density that is greater than 3mm in diameter. 2.Moderate to severe degree of cisternal herniation was found in 10 cases (17%): only 1 case before the age of 30, and 9 cases after the age of 30. 3.The lateral margins of cavernous sinus were bilaterally flat in 42 cases (72%), bilaterally convex in 3 cases (5%), unilaterally convex in 12 cases (21%), and unilaterally concave only in 1 case (2%). The third cranial nerves were found as symmetric filling defects in superolateral aspect of anterior cavernous sinus in most of the cases, the maximal size of which was 2.7 ± 0.9mm in diameter and did not exceed 3.5mm. The other cranial nerves were less frequently identified as

  18. Radioimmunoassay of serum group I and group II pepsinogens in normal controls and patients with various disorders

    International Nuclear Information System (INIS)

    Ichinose, M.; Miki, K.; Hayashi, R.; Niwa, H.; Oka, H.; Furihata, C.; Matsushima, T.; Kageyama, T.; Takahashi, K.

    1982-01-01

    A radioimmunoassay (RIA) for human group I pepsinogens (PgI) in serum was developed, using PgI purified from gastric mucosa. The sensitivity (0.7 μg/l) and reproducibility of the assay were satisfactory for clinical use. In normal controls total serum pepsinogen (T-Pg) level was 58.9 +- 31.7 μg/l (mean +- SD) (PgI, 43.6 +- 25.0 μg/l; PgII, 15.3 +- 11.1 μg/l). Peptic ulcer cases had elevated T-Pg levels (gastric ulcer, gastroduodenal ulcer and duodenal ulcer, in increasing order of magnitude). T-Pg levels were not useful for diagnosis of peptic ulcer because of a large overlap with normal controls. T-Pg levels were low in patients with gastric polyp and in aged subjects. In these groups, the decrease of PgI was more marked than that of PgII. (Auth.)

  19. Radioimmunoassay of serum group I and group II pepsinogens in normal controls and patients with various disorders

    Energy Technology Data Exchange (ETDEWEB)

    Ichinose, M.; Miki, K.; Hayashi, R.; Niwa, H.; Oka, H. (Tokyo Univ. (Japan). Faculty of Medicine); Furihata, C.; Matsushima, T. (Tokyo Univ. (Japan). Inst. for Medical Science); Kageyama, T.; Takahashi, K. (Kyoto Univ., Inuyama (Japan). Primate Research Inst.)

    1982-12-09

    A radioimmunoassay (RIA) for human group I pepsinogens (PgI) in serum was developed, using PgI purified from gastric mucosa. The sensitivity (0.7 ..mu..g/l) and reproducibility of the assay were satisfactory for clinical use. In normal controls total serum pepsinogen (T-Pg) level was 58.9 +- 31.7 ..mu..g/l (mean +- SD) (PgI, 43.6 +- 25.0 ..mu..g/l; PgII, 15.3 +- 11.1 ..mu..g/l). Peptic ulcer cases had elevated T-Pg levels (gastric ulcer, gastroduodenal ulcer and duodenal ulcer, in increasing order of magnitude). T-Pg levels were not useful for diagnosis of peptic ulcer because of a large overlap with normal controls. T-Pg levels were low in patients with gastric polyp and in aged subjects. In these groups, the decrease of PgI was more marked than that of PgII.

  20. Rectal compliance as a routine measurement: extreme volumes have direct clinical impact and normal volumes exclude rectum as a problem.

    Science.gov (United States)

    Felt-Bersma, R J; Sloots, C E; Poen, A C; Cuesta, M A; Meuwissen, S G

    2000-12-01

    The clinical impact of rectal compliance and sensitivity measurement is not clear. The aim of this study was to measure the rectal compliance in different patient groups compared with controls and to establish the clinical effect of rectal compliance. Anorectal function tests were performed in 974 consecutive patients (284 men). Normal values were obtained from 24 controls. Rectal compliance measurement was performed by filling a latex rectal balloon with water at a rate of 60 ml per minute. Volume and intraballoon pressure were measured. Volume and pressure at three sensitivity thresholds were recorded for analysis: first sensation, urge, and maximal toleration. At maximal toleration, the rectal compliance (volume/pressure) was calculated. Proctoscopy, anal manometry, anal mucosal sensitivity, and anal endosonography were also performed as part of our anorectal function tests. No effect of age or gender was observed in either controls or patients. Patients with fecal incontinence had a higher volume at first sensation and a higher pressure at maximal toleration (P = 0.03), the presence of a sphincter defect or low or normal anal pressures made no difference. Patients with constipation had a larger volume at first sensation and urge (P 500 ml had complaints of constipation. No correlation between rectal and anal mucosal sensitivity was found. Rectal compliance measurement with a latex balloon is easily feasible. In this series of 974 patients, some patient groups showed an abnormal rectal visceral sensitivity and compliance, but there was an overlap with controls. Rectal compliance measurement gave a good clinical impression about the contribution of the rectum to the anorectal problem. Patients with proctitis and pouchitis had the smallest rectal compliance. A maximal toleration volume 500 ml was only seen in constipated patients, and therapy should be given to prevent further damage to the pelvic floor. Values close to or within the normal range rule out the

  1. The ISNT Rule: How Often Does It Apply to Disc Photographs and Retinal Nerve Fiber Layer Measurements in the Normal Population?

    Science.gov (United States)

    Poon, Linda Yi-Chieh; Solá-Del Valle, David; Turalba, Angela V; Falkenstein, Iryna A; Horsley, Michael; Kim, Julie H; Song, Brian J; Takusagawa, Hana L; Wang, Kaidi; Chen, Teresa C

    2017-12-01

    To determine what percentage of normal eyes follow the ISNT rule, and whether ISNT rule variants may be more generalizable to the normal population. Cross-sectional study. Setting: Institutional setting. Total of 110 normal subjects. Neuroretinal rim assessments from disc photographs and retinal nerve fiber layer (RNFL) thickness measurements from spectral-domain optical coherence tomography. The percentages of subjects that obeyed the ISNT rule and its variants. The ISNT rule is only valid for 37.0% of disc photograph rim assessments and 43.8% of RNFL measurements. Deviation of the nasal sector from the expected ISNT pattern was a major cause for the ISNT rule not being obeyed for both rim and RNFL assessments. Specifically, 10.9% of subjects had wider nasal rims than the inferior rims, 29.4% had wider nasal rims than the superior rims, 14.7% had narrower nasal rims than the temporal rims, and 42.9% had thinner nasal RNFLs compared to the temporal quadrant. Exclusion of the nasal quadrant from the ISNT rule significantly increased the validity of ISNT variant rules, with 70.9% and 76.4% of disc photographs following the IST rule and the IS rule, respectively. Similarly, for RNFL thickness, 70.9% and 71.8% of patients followed the IST and IS rule, respectively. The ISNT rule is only valid for about a third of disc photographs and less than half of RNFL measurements in normal patients. ISNT rule variants, such as the IST and IS rule, may be considered, as they are valid in more than 70% of patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Multi-channel normal speed gated integrator in the measurement of the laser scattering light energy

    International Nuclear Information System (INIS)

    Yang Dong; Yu Xiaoqi; Hu Yuanfeng

    2005-01-01

    With the method of integration in a limited time, a Multi-channel normal speed gated integrator based on VXI system has been developed for measuring the signals with changeable pulse width in laser scattering light experiment. It has been tested with signal sources in ICF experiment. In tests, the integral nonlinearity between the integral results of the gated integrator and that of an oscilloscope is less than 1%. In the ICF experiments the maximum error between the integral results of the gated integrator and that of oscilloscope is less than 3% of the full scale range of the gated integrator. (authors)

  3. Bladder exstrophy: reconstructed female patients achieving normal pregnancy and delivering normal babies

    Directory of Open Access Journals (Sweden)

    Amílcar Martins Giron

    2011-10-01

    Full Text Available PURPOSE: Bladder exstrophy (BE is an anterior midline defect that causes a series of genitourinary and muscular malformations, which demands surgical intervention for correction. Women with BE are fertile and able to have children without this disease. The purpose of this study is to assess the sexual function and quality of life of women treated for BE. MATERIALS AND METHODS: All patients in our institution treated for BE from 1987 to 2007 were recruited to answer a questionnaire about their quality of life and pregnancies. RESULTS: Fourteen women were submitted to surgical treatment for BE and had 22 pregnancies during the studied period. From those, 17 pregnancies (77.2% resulted in healthy babies, while four patients (18.1% had a spontaneous abortion due to genital prolapse, and there was one case (4.7% of death due to a pneumopathy one week after delivery. There was also one case (5.8% of premature birth without greater repercussions. During pregnancy, three patients (21.4% had urinary tract infections and one patient (7.14% presented urinary retention. After delivery, three patients (21.4% presented temporary urinary incontinence; one patient (7.14% had a vesicocutaneous fistula and seven patients (50% had genital prolapsed. All patients confirmed to have achieved urinary continence, a regular sexual life and normal pregnancies. All patients got married and pregnant older than the general population. CONCLUSIONS: BE is a severe condition that demands medical and family assistance. Nevertheless, it is possible for the bearers of this condition to have a satisfactory and productive lifestyle.

  4. [Perception of UCI nurses in relation with satisfactory care: convergences and divergences with the perception of critical patients].

    Science.gov (United States)

    Jover-Sancho, C; Romero-García, M; Delgado-Hito, P; de la Cueva-Ariza, L; Solà-Solé, N; Acosta-Mejuto, B; Ricart-Basagaña, M T; Solà-Ribó, M; Juandó-Prats, C L

    2015-01-01

    Explore convergences and divergences between perception of nurses and of critically ill patients, in relation to the satisfactory care given and received. It is part of a larger qualitative study, according to the Grounded Theory. Carried out in 3 intensive care units with 34 boxes. Sampling theoretical profiles with n=19 patients and n=7 nurses after data saturation. Recruitment of patients included in the profiles of elderly and long-stay got stretched over some time due to the low incidence of cases. Data collection consisted of: in-depth interview to critically ill patients, group discussion of expert nurses in the critical care patient and field diary. Analysis themed on Grounded Theory according Strauss and Corbin: open coding, axial and selective. Analysis followed criteria of Guba and Lincoln rigor, Calderón quality and Gastaldo and McKeever ethical reflexivity. There was a favorable report from the ethical committee of the Hospital and informed consent of the participants. Four matching categories were found: professional skills, human, technical and continued care. Combination of these elements creates feelings of security, calmness and feeling like a person, allowing the patient a close and trusting relationship with the nurse who takes individualized care. Not divergent categories were found. Perceptions of nurses in relation to care match perceptions of critically ill patients in both the definition and dimensions upon satisfactory care. Copyright © 2014 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  5. Satisfactory treatment of a large connective tissue nevus with intralesional steroid injection.

    Science.gov (United States)

    Saki, Nasrin; Dorostkar, Azadeh; Heiran, Alireza; Aslani, Fatemeh Sari

    2018-01-01

    Collagenoma is a type of connective tissue nevi, a rare hamartomatous malformation characterized by the predominant proliferation of normal collagen fibers and normal, decreased, or increased elastic fibers. Collagenomas present as multiple or solitary, hereditary or sporadic, asymptomatic, skin-colored papules, nodules, and plaques with variable sizes, and are usually located on the trunk, arm, and back. Here, we report on a 14-year-old boy who presented with an isolated giant collagenoma of the frontal area that dramatically responded to intralesional triamcinolone acetonide.

  6. The development and application of a coincidence measurement apparatus with micro-computer system

    International Nuclear Information System (INIS)

    Du Hongshan; Zhou Youpu; Gao Junlin; Qin Deming; Cao Yunzheng; Zhao Shiping

    1987-01-01

    A coincidence measurement apparatus with micro-computer system is developed. Automatic data acquisition and processing are achieved. Results of its application for radioactive measurement are satisfactory

  7. Analysis of a simplified normalized covariance measure based on binary weighting functions for predicting the intelligibility of noise-suppressed speech.

    Science.gov (United States)

    Chen, Fei; Loizou, Philipos C

    2010-12-01

    The normalized covariance measure (NCM) has been shown previously to predict reliably the intelligibility of noise-suppressed speech containing non-linear distortions. This study analyzes a simplified NCM measure that requires only a small number of bands (not necessarily contiguous) and uses simple binary (1 or 0) weighting functions. The rationale behind the use of a small number of bands is to account for the fact that the spectral information contained in contiguous or nearby bands is correlated and redundant. The modified NCM measure was evaluated with speech intelligibility scores obtained by normal-hearing listeners in 72 noisy conditions involving noise-suppressed speech corrupted by four different types of maskers (car, babble, train, and street interferences). High correlation (r = 0.8) was obtained with the modified NCM measure even when only one band was used. Further analysis revealed a masker-specific pattern of correlations when only one band was used, and bands with low correlation signified the corresponding envelopes that have been severely distorted by the noise-suppression algorithm and/or the masker. Correlation improved to r = 0.84 when only two disjoint bands (centered at 325 and 1874 Hz) were used. Even further improvements in correlation (r = 0.85) were obtained when three or four lower-frequency (<700 Hz) bands were selected.

  8. Normal gravity field in relativistic geodesy

    Science.gov (United States)

    Kopeikin, Sergei; Vlasov, Igor; Han, Wen-Biao

    2018-02-01

    Modern geodesy is subject to a dramatic change from the Newtonian paradigm to Einstein's theory of general relativity. This is motivated by the ongoing advance in development of quantum sensors for applications in geodesy including quantum gravimeters and gradientometers, atomic clocks and fiber optics for making ultra-precise measurements of the geoid and multipolar structure of the Earth's gravitational field. At the same time, very long baseline interferometry, satellite laser ranging, and global navigation satellite systems have achieved an unprecedented level of accuracy in measuring 3-d coordinates of the reference points of the International Terrestrial Reference Frame and the world height system. The main geodetic reference standard to which gravimetric measurements of the of Earth's gravitational field are referred is a normal gravity field represented in the Newtonian gravity by the field of a uniformly rotating, homogeneous Maclaurin ellipsoid of which mass and quadrupole momentum are equal to the total mass and (tide-free) quadrupole moment of Earth's gravitational field. The present paper extends the concept of the normal gravity field from the Newtonian theory to the realm of general relativity. We focus our attention on the calculation of the post-Newtonian approximation of the normal field that is sufficient for current and near-future practical applications. We show that in general relativity the level surface of homogeneous and uniformly rotating fluid is no longer described by the Maclaurin ellipsoid in the most general case but represents an axisymmetric spheroid of the fourth order with respect to the geodetic Cartesian coordinates. At the same time, admitting a post-Newtonian inhomogeneity of the mass density in the form of concentric elliptical shells allows one to preserve the level surface of the fluid as an exact ellipsoid of rotation. We parametrize the mass density distribution and the level surface with two parameters which are

  9. Univariate normalization of bispectrum using Hölder's inequality.

    Science.gov (United States)

    Shahbazi, Forooz; Ewald, Arne; Nolte, Guido

    2014-08-15

    Considering that many biological systems including the brain are complex non-linear systems, suitable methods capable of detecting these non-linearities are required to study the dynamical properties of these systems. One of these tools is the third order cummulant or cross-bispectrum, which is a measure of interfrequency interactions between three signals. For convenient interpretation, interaction measures are most commonly normalized to be independent of constant scales of the signals such that its absolute values are bounded by one, with this limit reflecting perfect coupling. Although many different normalization factors for cross-bispectra were suggested in the literature these either do not lead to bounded measures or are themselves dependent on the coupling and not only on the scale of the signals. In this paper we suggest a normalization factor which is univariate, i.e., dependent only on the amplitude of each signal and not on the interactions between signals. Using a generalization of Hölder's inequality it is proven that the absolute value of this univariate bicoherence is bounded by zero and one. We compared three widely used normalizations to the univariate normalization concerning the significance of bicoherence values gained from resampling tests. Bicoherence values are calculated from real EEG data recorded in an eyes closed experiment from 10 subjects. The results show slightly more significant values for the univariate normalization but in general, the differences are very small or even vanishing in some subjects. Therefore, we conclude that the normalization factor does not play an important role in the bicoherence values with regard to statistical power, although a univariate normalization is the only normalization factor which fulfills all the required conditions of a proper normalization. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Quasiparticle transport properties of mesoscopic wires containing normal-metal/superconductor/normal-metal proximity junctions

    International Nuclear Information System (INIS)

    Kim, Nam; Kim, Kijoon; Lee, Hu Jong; Lee, Seongjae; Yuk, Jong Seol; Park, Kyoung Wan; Lee, El Hang

    1997-01-01

    We measured the differential resistance dV/dI of mesoscopic normal-metal/superconductor/normal-metal (N-S-N) junctions. At low temperatures (T PbIn /e, where Δ PbIn is the gap energy of superconducting Pb-In, and at a higher bias V c . The zero-bias dip is supposed to originate from Andreev reflections of quasiparticles and the peak near 2Δ PbIn /e from the formation of a standing-wave mode of quasiparticles inside the superconducting potential barrier. We attribute the peaks at V c to a transition of the superconducting region to the normal state as the current exceeds the critical current I c of S

  11. In-process hold-up as a measure of safeguards significance

    International Nuclear Information System (INIS)

    Hamlin, A.G.

    1983-01-01

    This paper examines the use of the in-process hold-up itself, as a measure of safeguards significance. It is argued that for any process plant it is possible to define design limits for in-process hold-up, outside which the plant will not operate, or will operate in a detectably abnormal manner. It follows, therefore, that if the in-process hold-up can be derived at frequent intervals by input/output analysis from the start of the campaign, the only diversion that can be made from it during that campaign is limited to the quantity necessary to move the apparent in-process hold-up from its normal operating condition to the upper limiting condition. It also follows that detection of this diversion is as positive for protracted diversion as for abrupt diversion. If that part of the in-process inventory that is only measurable by input/output analysis has an upper operating limit that differs from its normal operating limit by less than a significant safeguards quantity of the material in question, the IAEA's criteria for both quantity and timeliness can be met by a combination of input/output analysis to determine in-process hold-up during the campaign, together with a material balance over the campaign. The paper examines the possibility of applying this measure to process plants in general, discusses means of minimizing the in-process inventory that must be determined by input/output analysis, and the performance required of the input and output analysis. It concludes that with current precision of measurement and with one input and one output batch per day, each measured, the method would be satisfactory for a campaign lasting nearly a year and involving 6 tonnes of plutonium. The paper examines the considerable advantages in verification that would arise from limiting safeguards analyses to the two points of input and output. (author)

  12. Asymptotic normalization coefficients and astrophysical factors

    International Nuclear Information System (INIS)

    Mukhamedzhanov, A.M.; Azhari, A.; Clark, H.L.; Gagliardi, C.A.; Lui, Y.-W.; Sattarov, A.; Trache, L.; Tribble, R.E.; Burjan, V.; Kroha, V.; Carstoiu, F.

    2000-01-01

    The S factor for the direct capture reaction 7 Be(p,γ) 8 B can be found at astrophysical energies from the asymptotic normalization coefficients (ANC's) which provide the normalization of the tails of the overlap functions for 8 B → 7 Be + p. Peripheral transfer reactions offer a technique to determine these ANC's. Using this technique, the 10 B( 7 Be, 8 B) 9 Be and 14 N( 7 Be, 8 B) 13 C reactions have been used to measure the asymptotic normalization coefficient for 7 Be(p, γ) 8 B. These results provide an indirect determination of S 17 (0). Analysis of the existing 9 Be(p, γ) 10 B experimental data within the framework of the R-matrix method demonstrates that experimentally measured ANC's can provide a reasonable determination of direct radiative capture rates. (author)

  13. Improving and measuring inpatient documentation of medical care within the MS-DRG system: education, monitoring, and normalized case mix index.

    Science.gov (United States)

    Rosenbaum, Benjamin P; Lorenz, Robert R; Luther, Ralph B; Knowles-Ward, Lisa; Kelly, Dianne L; Weil, Robert J

    2014-01-01

    Documentation of the care delivered to hospitalized patients is a ubiquitous and important aspect of medical care. The majority of references to documentation and coding are based on the Centers for Medicare and Medicaid Services (CMS) Medicare Severity Diagnosis Related Group (MS-DRG) inpatient prospective payment system (IPPS). We educated the members of a clinical care team in a single department (neurosurgery) at our hospital. We measured subsequent documentation improvements in a simple, meaningful, and reproducible fashion. We created a new metric to measure documentation, termed the "normalized case mix index," that allows comparison of hospitalizations across multiple unrelated MS-DRG groups. Compared to one year earlier, the traditional case mix index, normalized case mix index, severity of illness, and risk of mortality increased one year after the educational intervention. We encourage other organizations to implement and systematically monitor documentation improvement efforts when attempting to determine the accuracy and quality of documentation achieved.

  14. Normal width of the anterior commissure of true vocal cord in Korea adults measured by helical CT

    International Nuclear Information System (INIS)

    Lim, Woo Young; Lim, Dong Hoon; Moon, Jang Il; Ko, Yong Seok; Byeon, Joo Nam; Oh, Jae Hee

    1998-01-01

    To evaluate the mean width of anterior commissure of true vocal cord in Korean adults by measuring its dimension on spiral CT scans. We reviewed the CT scans of 53 Korean adults(age range, 23-73years; mean age 39.2 years;M:F=3D41:12) without laryngeal disorders. Soiral CT scanning was performed around the anterior commissure with 1mm slice thickness and table incrementation for 15 seconds. The anteroposterior width of the anterior commissure was measured on CT scan where the true vocal cord and arytenoid, cricoid and thyroid cartilages were all present. We determined the mean width of the anterior commissure and whether there was a relationship between age and the width of the anterior commissure. The width of the anterior commissure was between 0.9mm and 2.3mm;mean width was 1.60±0.38mm(mean±SD). Using two SDs above the mean would have defined 2.36mm as the upper limit of normal width. Statistically, no significant correlation existed between the age and the width of the anterior commissure(p>0.05). An awareuess of the normal width range of the anterior commissure in Korean adults evaluated by spiral CT enhances the possibility of early detection of invasion of the anterior commissure by glottic cancer.=20

  15. [Comparison of objective optical quality measured by double-pass aberrometry in patients with moderate dry eye: Normal saline vs. artificial tears: A pilot study].

    Science.gov (United States)

    Vandermeer, G; Chamy, Y; Pisella, P-J

    2018-03-01

    Dry eye is defined by a tear film instability resulting in variable but systematic fluctuations in the quality of vision. Variability in optical quality can be demonstrated using a double pass aberrometer such as the OQAS (Optical Quality Analyzing System, Visiometrics). The goal of this work is to compare fluctuations in objective quality of vision measured by OQAS between treatment with normal saline eye drops and treatment with carmellose 0.5% and hyaluronic acid 0.1% (Optive Fusion [OF], Allergan) in patients with moderate dry eye syndrome. Optical quality was measured by evaluating the variations in the Optical Scattering Index (OSI) over 20seconds using the OQAS. Inclusion criteria were dry eye syndrome with an Ocular Surface Disease Index (OSDI) score>23 treated only with artificial tears. The patients were their own controls: OF in one eye and normal saline in the fellow eye. The choice of the subject eye and control eye was determined in a randomized fashion. OSI variations were measured in each eye before instillation, 5minutes and 2hours after instillation. The primary endpoint was OSI fluctuation over 20seconds of measurement. Secondary endpoints were the number of blinks and patient's preference (preferred eye). Preliminary results were obtained on 19 patients. Average OSDI score was 36.8. Visual acuity was 10/10 with no significant difference between the two eyes. Prior to instillation, there was no significant difference between "normal saline" and "OF" eyes in terms of OSI, OSI variability or number of blinks. In the normal saline eye, there was no significant variation in mean OSI, OSI variability, OSI slope, or number of blinks. However, in the "OF" eye, there was a significant variation between initial and 2-hour OSI variability (0.363 versus 0.204; Peye, 24% did not have a preference, and 11% preferred the normal saline eye. Objective quality of vision measured by OQAS is an interesting parameter for evaluating the effectiveness of a lacrimal

  16. Comparison of objective optical quality measured by double-pass aberrometry in patients with moderate dry eye: Normal saline vs. artificial tears: A pilot study.

    Science.gov (United States)

    Vandermeer, G; Chamy, Y; Pisella, P-J

    2018-02-01

    Dry eye is defined by a tear film instability resulting in variable but systematic fluctuations in quality of vision. Variability in optical quality can be demonstrated using a double pass aberrometer such as the Optical Quality Analyzing System, Visiometrics (OQAS). The goal of this work is to compare fluctuations in objective quality of vision measured by OQAS between treatment with normal saline eye drops and treatment with carmellose 0.5% and hyaluronic acid 0.1% (Optive Fusion [OF], Allergan) in patients with moderate dry eye syndrome. Optical quality was measured by evaluating the variations in the Optical Scattering Index (OSI) over 20seconds using the OQAS. Inclusion criteria were dry eye syndrome with an ocular surface disease index (OSDI) score >23 treated only with artificial tears. The patients were their own controls: OF in one eye and normal saline in the fellow eye. The choice of the subject eye and control eye was determined in a randomized fashion. OSI variations were measured in each eye before instillation, 5minutes and 2hours after instillation. The primary endpoint was OSI fluctuation over 20seconds of measurement. Secondary endpoints were the number of blinks and patient preference (preferred eye). Preliminary results were obtained on 19 patients. Average OSDI score was 36.8. Visual acuity was 10/10 with no significant difference between the two eyes. Prior to instillation, there was no significant difference between "normal saline" and "OF" eyes in terms of OSI, OSI variability or number of blinks. In the normal saline eye, there were no significant variations in mean OSI, OSI variability, OSI slope, or number of blinks. However, in the "OF" eye, there was a significant variation between initial and 2-hour OSI variability (0.363 versus 0.204, Peye, 24% did not have a preference, and 11% preferred the normal saline eye. Objective quality of vision measured by OQAS is an interesting parameter for evaluating the effectiveness of a lacrimal

  17. Measurement of normal corpus callosum with MRI in Korean adults and morphological change of corpus callosum by grade of hydrocephalus

    International Nuclear Information System (INIS)

    Song, Dong Hoon; Chang, Seung Kuk; Kim, Jong Deok; Eun, Tchoong Kie; Park, Dong Woo

    1995-01-01

    To measure the size of normal corpus callosum in each portion using objective and reproducible method with MRI and evaluation of morphological change of corpus callosum by grade of hydrocephalus. Midsagittal T1-weighted MR imaging of the corpus callosum was investigated in 41 volunteers of normal Korean adults and 19 patients with hydrocephalus. Corpus callosum was measured for the anteroposterior length(A), height(B), and the thickness of genu(C), body(D), splenium(E), and the narrowest portion of body(F). And the analysis of morphology and signal intensity of the corpus callosum were also evaluated. Hydrocephalus was graded as mild, moderate, and severe, and comparison of thickness with normal corpus callosum in each portion was done. The mean length and height were 72.3 mm, 28.6 mm in male, and 70.7 mm, 28.9 mm in female. And the mean dimension for C, D, E and F were 13.1 mm, 8 mm, 13.2 mm, 5.2 mm in male, and 12.8 mm, 7.5 mm, 12.3 mm, 5 mm in female. The morphology of normal corpus callosum was 'hook' shaped on midline sagittal T1-weighted image. Narrowing at posterior third portion of body were present on 30 cases(73.2%) and even in thickness of the body in 11 cases(26.8%). The signal intensity of the corpus callosum on midsagittal T1-weighted spin echo image of normal cases was homogeneous hyperintense as compared with cerebral gray matter. In hydrocephalus, A and B were increased and other portions were decreased in thickness. Genu and the narrowest portion of body showed significant difference of thickness according to the grade of hydrocephalus. The mean dimension of all portion of corpus callosum were larger in male than female except for callosal height but not significant statistically with the exception of splenium. Hydrocephalus lead to morphological change of the corpus callosum. Among the portion of corpus callosum, genu and the narrowest portion of the body were thought to be the most sensitive indicators of degree in hydrocephalus

  18. Normal development of brainstem in childhood. Measurement of the area on mid-sagittal MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kutomi, Kimiko [Teikyo Univ., Tokyo (Japan). Faculty of Medicine

    2005-05-01

    Developmental abnormality of brainstem is shown in pediatric patients with mental retardation, autism, periventricular leukomalacia, neurodegenerative disease, and so on. Our purpose here is to clarify the normal developmental pattern of the brainstem. We measured the area of tectum, midbrain tegmentum, pons, basis pontis and pontine tegmentum on mid-sagittal MR images in 111 children (newborn to 20 year old). Different growth patterns were shown in all parts of the brainstem. Tectum showed a subtle increase in area from the newborn to adult period, while midbrain tegmentum and pontine tegmenturn showed a mild and gradual increase in area. Pons and pontine tegmentum showed a rapid and prominent increase in area from newborn to infant period and gradual increase in area until the adult period. These different growth patterns seemed to be consistent with differences in the myelination cycles of the neuronal fibers, maturation of the nuclei and proliferation of glial cells in each part of the brainstem. Mid-sagittal MR imaging of the head is accurate and reproducible and is used conveniently in routine head MR study, making it very useful for the diagnosis of many central nervous diseases and anomalies. We believe that this new milestone provided in this study will be helpful in distinguishing normal children from those that have neurodegenerative disorders. (author)

  19. Normal development of brainstem in childhood. Measurement of the area on mid-sagittal MR imaging

    International Nuclear Information System (INIS)

    Kutomi, Kimiko

    2005-01-01

    Developmental abnormality of brainstem is shown in pediatric patients with mental retardation, autism, periventricular leukomalacia, neurodegenerative disease, and so on. Our purpose here is to clarify the normal developmental pattern of the brainstem. We measured the area of tectum, midbrain tegmentum, pons, basis pontis and pontine tegmentum on mid-sagittal MR images in 111 children (newborn to 20 year old). Different growth patterns were shown in all parts of the brainstem. Tectum showed a subtle increase in area from the newborn to adult period, while midbrain tegmentum and pontine tegmenturn showed a mild and gradual increase in area. Pons and pontine tegmentum showed a rapid and prominent increase in area from newborn to infant period and gradual increase in area until the adult period. These different growth patterns seemed to be consistent with differences in the myelination cycles of the neuronal fibers, maturation of the nuclei and proliferation of glial cells in each part of the brainstem. Mid-sagittal MR imaging of the head is accurate and reproducible and is used conveniently in routine head MR study, making it very useful for the diagnosis of many central nervous diseases and anomalies. We believe that this new milestone provided in this study will be helpful in distinguishing normal children from those that have neurodegenerative disorders. (author)

  20. Comparison of International Normalized Ratio Measurement between CoaguChek XS Plus and STA-R Coagulation Analyzers

    Directory of Open Access Journals (Sweden)

    Mina Hur

    2013-01-01

    Full Text Available Background. Point-of-care testing (POCT coagulometers are increasingly being used in the hospital setting. We investigated whether the prothrombin time international normalized ratio (INR results by CoaguChek XS Plus (Roche Diagnostics GmbH, Mannheim, Germany can be used reliably without being confirmed with the INR results by STA-R system (Diagnostica Stago S.A.S, Asnières sur Seine, France. Methods. A total of 118 INR measurements by CoaguChek XS Plus and STA-R were compared using Passing/Bablok regression analysis and Bland-Altman plot. Agreement of the INR measurements was further assessed in relation to dosing decision. Results. The correlation of INR measurements between CoaguChek XS Plus and STA-R was excellent (correlation coefficient = 0.964. The mean difference tended to increase as INR results increased and was 0.25 INR in the therapeutic range (2.0-3.0 INR. The overall agreement was fair to good (kappa = 0.679, and 21/118 (17.8% INR measurements showed a difference in dosing decision. Conclusion. The positive bias of CoaguChek XS Plus may be obvious even in the therapeutic INR range, and dosing decision based on the CoaguChek XS Plus INR results would be different from that based on the STA-R results. The INR measurements by POCT coagulometers still need to be confirmed with the laboratory INR measurements.

  1. Satisfactory arterial repair 1 year after ultrathin strut biodegradable polymer sirolimus-eluting stent implantation: an angioscopic observation.

    Science.gov (United States)

    Ishihara, Takayuki; Awata, Masaki; Iida, Osamu; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Uematsu, Masaaki; Mano, Toshiaki

    2018-01-15

    The ultrathin strut biodegradable polymer sirolimus-eluting stent (Orsiro, O-SES) exhibits satisfactory clinical outcomes. However, no report to date has documented the intravascular status of artery repair after O-SES implantation. We examined 5 O-SES placed in 4 patients (age 65 ± 12 years, male 75%) presenting with stable angina pectoris due to de novo lesions in native coronary arteries. Coronary angioscopy was performed immediately after percutaneous coronary intervention and 1 year later. Angioscopic images were analyzed to determine the following: (1) dominant grade of neointimal coverage (NIC) over the stent; (2) maximum yellow plaque grade; and (3) existence of thrombus. Yellow plaque grade was evaluated both immediately after stent implantation and at the time of follow-up observation. The other parameters were evaluated at the time of follow-up examination. NIC was graded as: grade 0, stent struts exposed; grade 1, struts bulging into the lumen, although covered; grade 2, struts embedded in the neointima, but translucent; grade 3, struts fully embedded and invisible. Yellow plaque severity was graded as: grade 0, white; grade 1, light yellow; grade 2, yellow; and grade 3, intensive yellow. Angioscopic findings at 1 year demonstrated the following: dominant NIC grade 1, grade 2, and grade 3 in 1, 2, and 2 stents, respectively; all stents were covered to some extent; focal thrombus adhesion was observed in only 1 stent. Yellow plaque grade did not change from immediately after stent implantation to follow-up. O-SES demonstrated satisfactory arterial repair 1 year after implantation.

  2. Predictors of satisfactory improvements in pain for patients with early rheumatoid arthritis in a treat-to-target study.

    Science.gov (United States)

    Ten Klooster, Peter M; Vonkeman, Harald E; Oude Voshaar, Martijn A H; Siemons, Liseth; van Riel, Piet L C M; van de Laar, Mart A F J

    2015-06-01

    The aim of this study was to identify baseline predictors of achieving patient-perceived satisfactory improvement (PPSI) in pain after 6 months of treat to target in patients with early RA. Baseline and 6 month data were used from patients included in the Dutch Rheumatoid Arthritis Monitoring remission induction cohort study. Simple and multivariable logistic regression analyses were used to identify significant predictors of achieving an absolute improvement of 30 mm or a relative improvement of 50% on a visual analogue scale for pain. At 6 months, 125 of 209 patients (59.8%) achieved an absolute PPSI and 130 patients (62.2%) achieved a relative PPSI in pain. Controlling for baseline pain, having symmetrical arthritis was the strongest independent predictor of achieving an absolute [odds ratio (OR) 3.17, P = 0.03] or relative (OR 3.44, P = 0.01) PPSI. Additionally, anti-CCP positivity (OR 2.04, P = 0.04) and having ≤12 tender joints (OR 0.29, P = 0.01) were predictive of achieving a relative PPSI. The total explained variance of baseline predictors was 30% for absolute and 18% for relative improvements, respectively. Symmetrical joint involvement, anti-CCP positivity and fewer tender joints at baseline are prognostic signs for achieving satisfactory improvement in pain after 6 months of treat to target in patients with early RA. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Reference Clinical Database for Fixation Stability Metrics in Normal Subjects Measured with the MAIA Microperimeter.

    Science.gov (United States)

    Morales, Marco U; Saker, Saker; Wilde, Craig; Pellizzari, Carlo; Pallikaris, Aristophanes; Notaroberto, Neil; Rubinstein, Martin; Rui, Chiara; Limoli, Paolo; Smolek, Michael K; Amoaku, Winfried M

    2016-11-01

    The purpose of this study was to establish a normal reference database for fixation stability measured with the bivariate contour ellipse area (BCEA) in the Macular Integrity Assessment (MAIA) microperimeter. Subjects were 358 healthy volunteers who had the MAIA examination. Fixation stability was assessed using two BCEA fixation indices (63% and 95% proportional values) and the percentage of fixation points within 1° and 2° from the fovea (P1 and P2). Statistical analysis was performed with linear regression and Pearson's product moment correlation coefficient. Average areas of 0.80 deg 2 (min = 0.03, max = 3.90, SD = 0.68) for the index BCEA@63% and 2.40 deg 2 (min = 0.20, max = 11.70, SD = 2.04) for the index BCEA@95% were found. The average values of P1 and P2 were 95% (min = 76, max = 100, SD = 5.31) and 99% (min = 91, max = 100, SD = 1.42), respectively. The Pearson's product moment test showed an almost perfect correlation index, r = 0.999, between BCEA@63% and BCEA@95%. Index P1 showed a very strong correlation with BCEA@63%, r = -0.924, as well as with BCEA@95%, r = -0.925. Index P2 demonstrated a slightly lower correlation with both BCEA@63% and BCEA@95%, r = -0.874 and -0.875, respectively. The single parameter of the BCEA@95% may be taken as accurately reporting fixation stability and serves as a reference database of normal subjects with a cutoff area of 2.40 ± 2.04 deg 2 in MAIA microperimeter. Fixation stability can be measured with different indices. This study originates reference fixation values for the MAIA using a single fixation index.

  4. Plasma digoxin concentrations and urinary excretion during a 'simpler' regimen of infant digitalization.

    Science.gov (United States)

    Savage, M O; Hibble, A G; Pickering, D

    1975-01-01

    We have measured the plasma concentrations in sick neonates and infants being administered digoxin by a safer regimen. In the presence of normal renal function the plasma concentrations appear to be satisfactory. PMID:1103751

  5. Influence of Time-Series Normalization, Number of Nodes, Connectivity and Graph Measure Selection on Seizure-Onset Zone Localization from Intracranial EEG.

    Science.gov (United States)

    van Mierlo, Pieter; Lie, Octavian; Staljanssens, Willeke; Coito, Ana; Vulliémoz, Serge

    2018-04-26

    We investigated the influence of processing steps in the estimation of multivariate directed functional connectivity during seizures recorded with intracranial EEG (iEEG) on seizure-onset zone (SOZ) localization. We studied the effect of (i) the number of nodes, (ii) time-series normalization, (iii) the choice of multivariate time-varying connectivity measure: Adaptive Directed Transfer Function (ADTF) or Adaptive Partial Directed Coherence (APDC) and (iv) graph theory measure: outdegree or shortest path length. First, simulations were performed to quantify the influence of the various processing steps on the accuracy to localize the SOZ. Afterwards, the SOZ was estimated from a 113-electrodes iEEG seizure recording and compared with the resection that rendered the patient seizure-free. The simulations revealed that ADTF is preferred over APDC to localize the SOZ from ictal iEEG recordings. Normalizing the time series before analysis resulted in an increase of 25-35% of correctly localized SOZ, while adding more nodes to the connectivity analysis led to a moderate decrease of 10%, when comparing 128 with 32 input nodes. The real-seizure connectivity estimates localized the SOZ inside the resection area using the ADTF coupled to outdegree or shortest path length. Our study showed that normalizing the time-series is an important pre-processing step, while adding nodes to the analysis did only marginally affect the SOZ localization. The study shows that directed multivariate Granger-based connectivity analysis is feasible with many input nodes (> 100) and that normalization of the time-series before connectivity analysis is preferred.

  6. Valuation of Normal Range of Ankle Systolic Blood Pressure in Subjects with Normal Arm Systolic Blood Pressure.

    Science.gov (United States)

    Gong, Yi; Cao, Kai-wu; Xu, Jin-song; Li, Ju-xiang; Hong, Kui; Cheng, Xiao-shu; Su, Hai

    2015-01-01

    This study aimed to establish a normal range for ankle systolic blood pressure (SBP). A total of 948 subjects who had normal brachial SBP (90-139 mmHg) at investigation were enrolled. Supine BP of four limbs was simultaneously measured using four automatic BP measurement devices. The ankle-arm difference (An-a) on SBP of both sides was calculated. Two methods were used for establishing normal range of ankle SBP: the 99% method was decided on the 99% reference range of actual ankle BP, and the An-a method was the sum of An-a and the low or up limits of normal arm SBP (90-139 mmHg). Whether in the right or left side, the ankle SBP was significantly higher than the arm SBP (right: 137.1 ± 16.9 vs 119.7 ± 11.4 mmHg, P<0.05). Based on the 99% method, the normal range of ankle SBP was 94~181 mmHg for the total population, 84~166 mmHg for the young (18-44 y), 107~176 mmHg for the middle-aged(45-59 y) and 113~179 mmHg for the elderly (≥ 60 y) group. As the An-a on SBP was 13 mmHg in the young group and 20 mmHg in both middle-aged and elderly groups, the normal range of ankle SBP on the An-a method was 103-153 mmHg for young and 110-160 mmHg for middle-elderly subjects. A primary reference for normal ankle SBP was suggested as 100-165 mmHg in the young and 110-170 mmHg in the middle-elderly subjects.

  7. Inverted Lobes Have Satisfactory Functions Compared With Noninverted Lobes in Lung Transplantation.

    Science.gov (United States)

    Kayawake, Hidenao; Chen-Yoshikawa, Toyofumi F; Motoyama, Hideki; Hamaji, Masatsugu; Hijiya, Kyoko; Aoyama, Akihiro; Goda, Yasufumi; Oda, Hiromi; Ueda, Satoshi; Date, Hiroshi

    2018-04-01

    To overcome the problem of small-for-size grafts in standard living-donor lobar lung transplantation (LDLLT), we developed inverted LDLLT, in which a right lower lobe from 1 donor is implanted as a right graft and another right lower lobe from another donor is implanted as a left graft. We retrospectively analyzed the functions of inverted grafts vs noninverted grafts. Between 2008 and 2015, 64 LDLLTs were performed. Included were 35 LDLLTs whose recipients were adults and monitored for more than 6 months without developing chronic lung allograft dysfunction. Among them, 65 implanted lobes were eligible for this analysis. There were 31 right lower lobes implanted as right grafts (right-to-right group), 7 right lower lobes as inverted left grafts (right-to-left group), and 27 left lower lobes as left grafts (left-to-left group). We evaluated the graft forced vital capacity (G-FVC) and graft volume of the 65 lobes before and 6 months after LDLLT and compared them among the three groups. Preoperatively, G-FVC in the right-to-left group (1,050 mL) was comparable to that in the right-to-right group (1,177 mL) and better than that in the left-to-left group (791 mL, p satisfactory compared with those of noninverted grafts. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. [MESGI50 study: description of a cohort on Maturity and Satisfactory Ageing].

    Science.gov (United States)

    Corominas Barnadas, Josep María; López-Pousa, Secundino; Vilalta-Franch, Joan; Calvó-Perxas, Laia; Juvinyà Canal, Dolors; Garre-Olmo, Josep

    To describe the demographic, health and socio-economic characteristics of the participants in the Study on Maturity and Satisfactory Ageing in Girona (MESGI50 study). Population-based Study linked to the Survey of Health, Ageing, and Retirement in Europe (SHARE). The reference population was the inhabitants of the province of Girona (Spain) aged 50 and over. A probabilistic two-stage stratified cluster sampling according to the number of inhabitants and the degree of ageing of the population was used. Twenty-eight municipalities were randomly selected according to their type (demographically aged or young), and then stratified by the population size. The response rate was 65% with a mean of 1.7 eligible individuals per household and a final sample of 2,065 households and 3,331 participants. The design effect was 1.27. 52.9% were women and the mean age was 66.9 years (SD=11.5). The self-rated health status, hand grip strength, restriction in daily life activities and depressive symptomatology increased with age and more markedly in women. There were differences in alcohol consumption and eating patterns depending on the area of residence. The demographic, health and socio-economic characteristics during the ageing process differ depending on age group, gender, and area of residence. Copyright © 2016 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Normal Corpus Callosum Dimensions Measured by MRI

    International Nuclear Information System (INIS)

    Kim, Ham Gyum

    2008-01-01

    As a result of measuring the size of corpus callosum in normal Korean people by using MRI, the following conclusions were obtained. 1. Maximum, minimum, and mean values by the region in whole subjects 1) Anteroposterior length amounted to the mean with 69.30 mm, the minimum with 50.70 mm, and the maximum with 80.40 mm. 2) Diameter of genu amounted to the mean with 11.93 mm, the minimum with 6.00 mm, and the maximum with 18.50 mm. 3) Diameter of mid body amounted to the mean with 7.00 mm, the minimum with 3.40 mm, and the maximum with 10.40 mm. 4) Diameter of narrowing portion amounted to the mean with 4.51 mm, the minimum with 0.80 mm, and the maximum with 9.50 mm. 5) Diameter of splenium amounted to the mean with 12.17 mm, the minimum with 6.90 mm, and the maximum with 17.20 mm. 2. Comparison by region according to the gender in the whole subjects 1) Anteroposterior length was bigger in men than in women, and showed the significant difference depending on gender. 2) Diameter of genu, diameter of mid body, and diameter of narrowing portion were bigger in men than in women, but there was no significant difference. 3) Diameter of splenium was bigger in men than in women, and showed the statistically significant difference. 3. Comparison by region according to the age in the whole subjects 1) Anteroposterior length was the biggest in the 50s at the age, and was smaller in heir 10s than other age levels. In addition, the significant difference was indicated depending on age. 2) Diameter of genu and diameter of mid body were the biggest in their 30s, and were smaller in the 60s than other age levels. And, the statistically significant difference was indicated. 3) Diameter of narrowing portion was the thickest in their 20s, and was thinner in their 60s than other age levels. And, the significant difference was indicated depending on age. 4) Diameter of splenium was the thickest in their 30s, and was thinner in their 10s than other age levels. And, the statistically

  10. Oxygen Supplementation to Stabilize Preterm Infants in the Fetal to Neonatal Transition: No Satisfactory Answer.

    Science.gov (United States)

    Torres-Cuevas, Isabel; Cernada, Maria; Nuñez, Antonio; Escobar, Javier; Kuligowski, Julia; Chafer-Pericas, Consuelo; Vento, Maximo

    2016-01-01

    Fetal life elapses in a relatively low oxygen environment. Immediately after birth with the initiation of breathing, the lung expands and oxygen availability to tissue rises by twofold, generating a physiologic oxidative stress. However, both lung anatomy and function and the antioxidant defense system do not mature until late in gestation, and therefore, very preterm infants often need respiratory support and oxygen supplementation in the delivery room to achieve postnatal stabilization. Notably, interventions in the first minutes of life can have long-lasting consequences. Recent trials have aimed to assess what initial inspiratory fraction of oxygen and what oxygen targets during this transitional period are best for extremely preterm infants based on the available nomogram. However, oxygen saturation nomogram informs only of term and late preterm infants but not on extremely preterm infants. Therefore, the solution to this conundrum may still have to wait before a satisfactory answer is available.

  11. Defecography: A study of normal volunteers

    International Nuclear Information System (INIS)

    Shorvon, P.; Stevenson, G.W.; McHugh, S.; Somers, P.

    1987-01-01

    This study of young volunteers was set up in an effort to establish true normal measurements for defecography with minimum selection bias. The results describe the mean (and the range) for the following: anorectal angle; anorectal junction position at rest; excursion on lift, strain, and evacuation; anal canal length and degree of closure; and the frequency and degree of features such as rectocele and intussusception which have previously been called abnormalities. The results indicate that there is a very wide range of normal appearances. Knowledge of these normal variations is important to avoid overreporting and unnecessary surgery

  12. Reduction in mean cerebral blood flow measurements using 99mTc-ECD-SPECT during normal aging

    International Nuclear Information System (INIS)

    Kawahata, Nobuya; Daitoh, Nobuyuki; Shirai, Fumie; Hara, Shigeru

    1997-01-01

    Mean cerebral blood flow (mCBF) was measured by SPECT using the 99m Tc-ECD-Patlak-Plot method in a selected group of 61 normal non-hospitalized subjects aged 51 to 91 years. The mCBF values showed 48.4±4.7 ml/100 g/min in aged 50-59 years group, 49.9±5.9 ml/100 g/min in aged 60-69 years group, 46.4 ±6.5 ml/100 g/min in aged 70-79 group, 38.0±3.7 ml/100 g/min in aged 80-89 years group, 38.9 ml/100 g/min in aged 90-99 years group. There was a statistically significant reduction of mCBF with advancing age (R=-0.41; p=0.001). Women have significantly higher mCBF values than men up to aged 70 years group. In this study, there was no significant laterality in the mCBF between right and left hemispheres in all decade groups. The history of hypertension, alcohol consumption, and cigarette smoking failed to show significant difference in the mCBF values. The present study shows that normal aging is associated with mCBF reduction. (author)

  13. Normal Weight Dyslipidemia

    DEFF Research Database (Denmark)

    Ipsen, David Hojland; Tveden-Nyborg, Pernille; Lykkesfeldt, Jens

    2016-01-01

    Objective: The liver coordinates lipid metabolism and may play a vital role in the development of dyslipidemia, even in the absence of obesity. Normal weight dyslipidemia (NWD) and patients with nonalcoholic fatty liver disease (NAFLD) who do not have obesity constitute a unique subset...... of individuals characterized by dyslipidemia and metabolic deterioration. This review examined the available literature on the role of the liver in dyslipidemia and the metabolic characteristics of patients with NAFLD who do not have obesity. Methods: PubMed was searched using the following keywords: nonobese......, dyslipidemia, NAFLD, NWD, liver, and metabolically obese/unhealthy normal weight. Additionally, article bibliographies were screened, and relevant citations were retrieved. Studies were excluded if they had not measured relevant biomarkers of dyslipidemia. Results: NWD and NAFLD without obesity share a similar...

  14. Experimental microangiographic study in normal rabbit liver

    International Nuclear Information System (INIS)

    Kim, Yoon Gyoo; Park, Jong Yeon; Han, Kook Sang; Moon, Ki Ho; Choi, Chang Ho; Han, Koon Taek; Lee, Suck Hong; Kim, Byung Soo

    1994-01-01

    Microangiography is an experimental radiologic technique for evaluation of the morphology and the function of small vessels. The purpose of this study is to introduce a good microangiographic technique and to present the microangiographic appearance of normal hepatic vascular pattern. Five white rabbits weighing 2.5-2.9Kg were objected. Polyethylene catheters were inserted in portal vein and then in IVC. Heparin mixed normal saline (2cc/1000cc) was infused through portal vein and blood was drained to IVC. Barium suspension was infused via the catheter placed in portal vein until the liver surface showed satisfactory finding in barium filling. The liver was removed and this preparation was fixed in 10% formaline for 7 days. After fixation, the liver was sectioned on 1-2mm thickness. The slices were radiographed on high resolution plate using Faxitron. H-E staining of liver tissue was also done. The microbrium was well distributed in all small vessels without filling defect. And we could find the hexagonal shaped classic liver lobule, in which the central vein was located at central portion and portal vein at periphery. The enlargement was showed numerous sinusoids, but there was less dye in the central portion of lobule, but the central vein was well filled by microbarium. The peripheral portion of lobule was well filled with microbarium. So, we could find diamond shaped liver acinus, in which central vein was located at priperal portion and the center of liver acinus was terminal portal vein that growed out from a small portal space. The three acini made the complex acinus and acinar agglomerate was composed of three or four complex acini. It is considered that the liver acinus pattern of Rapparport is more acceptable on microangiography than the classic concept of hepatic lobule

  15. Measurement of activity-weighted size distributions of radon decay products in a normally occupied home

    International Nuclear Information System (INIS)

    Hopke, P.K.; Wasiolek, P.; Montassier, N.; Cavallo, A.; Gadsby, K.; Socolow, R.

    1992-01-01

    In order to assess the exposure of individuals to the presence of indoor radioactivity arising from the decay of radon, an automated, semicontinuous graded screen array system was developed to permit the measurement of the activity-weighted size distributions of the radon progeny in homes. The system has been modified so that the electronics and sampling heads can be separated from the pump by approximately 15 m. The system was placed in the living room of a one-storey house with basement in Princeton, NJ and operated for 2 weeks while the house was occupied by the home owners in their normal manner. One of the house occupants was a cigarette smoker. Radon and potential alpha energy concentration (PAEC) measurements were also made, but condensation nuclei counts were not performed. PAEC values ranged from 23.4 to 461.6 mWL. In the measured activity size distributions, the amount of activity in the 0.5-1.5 nm size range can be considered to be the unattached fraction. The mean value for the 218 Po unattached fraction is 0.217 with a range of 0.054-0.549. The median value for the unattached fraction of PAEC is 0.077 with a range of 0.022-0.178. (author)

  16. Evaluating new methods for direct measurement of the moderator temperature coefficient in nuclear power plants during normal operation

    International Nuclear Information System (INIS)

    Makai, M.; Kalya, Z.; Nemes, I.; Pos, I.; Por, G.

    2007-01-01

    Moderator temperature coefficient of reactivity is not monitored during fuel cycles in WWER reactors, because it is not very easy or impossible to measure it without disturbing the normal operation. Two new methods were tested in our WWER type nuclear power plant to try methodologies, which enable to measure that important to safety parameter during the fuel cycle. One is based on small perturbances, and only small changes are requested in operation, the other is based on noise methods, which means it is without interference with reactor operation. Both method is new that aspects that they uses the plant computer data(VERONA) based signals calculated by C P ORCA diffusion code (Authors)

  17. Adherence to hand hygiene guidelines - significance of measuring fidelity.

    Science.gov (United States)

    Korhonen, Anne; Ojanperä, Helena; Puhto, Teija; Järvinen, Raija; Kejonen, Pirjo; Holopainen, Arja

    2015-11-01

    The aim was to evaluate the usability of fidelity measures in compliance evaluation of hand hygiene. Adherence to hand hygiene guidelines is important in terms of patient safety. Compliance measures seldom describe how exactly the guidelines are followed. A cross-sectional observation study in a university hospital setting was conducted. Direct observation by trained staff was performed using a standardised observation form supplemented by fidelity criteria. A total of 830 occasions were observed in 13 units. Descriptive statistics (frequency, mean, percentages and range) were used as well as compliance rate by using a standard web-based tool. In addition, the binomial standard normal deviate test was conducted for comparing different methods used in evaluation of hand hygiene and in comparison between professional groups. Measuring fidelity to guidelines was revealed to be useful in uncovering gaps in hand hygiene practices. The main gap related to too short duration of hand rubbing. Thus, although compliance with hand hygiene guidelines measured using a standard web-based tool was satisfactory, the degree of how exactly the guidelines were followed seemed to be critical. Combining the measurement of fidelity to guidelines with the compliance rate is beneficial in revealing inconsistency between optimal and actual hand hygiene behaviour. Evaluating fidelity measures is useful in terms of revealing the gaps between optimal and actual performance in hand hygiene. Fidelity measures are suitable in different healthcare contexts and easy to measure according to the relevant indicators of fidelity, such as the length of hand rubbing. Knowing the gap facilitates improvements in clinical practice. © 2015 John Wiley & Sons Ltd.

  18. L-Band Radiometers Measuring Salinity From Space: Atmospheric Propagation Effects

    DEFF Research Database (Denmark)

    Skou, Niels; Hofman-Bang, Dorthe

    2005-01-01

    Microwave radiometers can measure sea surface salinity from space using L-band frequencies around 1.4 GHz. However, requirements to the accuracy of the measurements, in order to be satisfactory for the user, are so stringent that the influence of the intervening atmosphere cannot be neglected...

  19. Normalization of cortical thickness measurements across different T1 magnetic resonance imaging protocols by novel W-Score standardization.

    Science.gov (United States)

    Chung, Jinyong; Yoo, Kwangsun; Lee, Peter; Kim, Chan Mi; Roh, Jee Hoon; Park, Ji Eun; Kim, Sang Joon; Seo, Sang Won; Shin, Jeong-Hyeon; Seong, Joon-Kyung; Jeong, Yong

    2017-10-01

    The use of different 3D T1-weighted magnetic resonance (T1 MR) imaging protocols induces image incompatibility across multicenter studies, negating the many advantages of multicenter studies. A few methods have been developed to address this problem, but significant image incompatibility still remains. Thus, we developed a novel and convenient method to improve image compatibility. W-score standardization creates quality reference values by using a healthy group to obtain normalized disease values. We developed a protocol-specific w-score standardization to control the protocol effect, which is applied to each protocol separately. We used three data sets. In dataset 1, brain T1 MR images of normal controls (NC) and patients with Alzheimer's disease (AD) from two centers, acquired with different T1 MR protocols, were used (Protocol 1 and 2, n = 45/group). In dataset 2, data from six subjects, who underwent MRI with two different protocols (Protocol 1 and 2), were used with different repetition times, echo times, and slice thicknesses. In dataset 3, T1 MR images from a large number of healthy normal controls (Protocol 1: n = 148, Protocol 2: n = 343) were collected for w-score standardization. The protocol effect and disease effect on subjects' cortical thickness were analyzed before and after the application of protocol-specific w-score standardization. As expected, different protocols resulted in differing cortical thickness measurements in both NC and AD subjects. Different measurements were obtained for the same subject when imaged with different protocols. Multivariate pattern difference between measurements was observed between the protocols. Classification accuracy between two protocols was nearly 90%. After applying protocol-specific w-score standardization, the differences between the protocols substantially decreased. Most importantly, protocol-specific w-score standardization reduced both univariate and multivariate differences in the images while

  20. Appropriate Similarity Measures for Author Cocitation Analysis

    NARCIS (Netherlands)

    N.J.P. van Eck (Nees Jan); L. Waltman (Ludo)

    2007-01-01

    textabstractWe provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of

  1. DNA double-strand breaks measured by pulsed-field gel electrophoresis in irradiated lymphocytes from normal humans and those with Alzheimer's disease

    International Nuclear Information System (INIS)

    Tobi, S.E.; Itzhaki, R.F.

    1993-01-01

    The authors previously found that radiation-induced chromosome aberrations (dicentrics) are more numerous in lymphocytes from Alzheimer's disease (AD) patients than in those from age-matched normal individuals (Tobi et al. 1990). They have examined double-strand breaks (dsb) produced by g amma - irradiation in the DNA of AD and normal lymphocytes by using pulsed-field gel electrophoresis. The percentage of DNA migrating into the gels is an indirect measure of the number of dsb; DNA content of sequential slices of the gel was assayed by direct fluorometry and the percentage migrating was dose dependent. Results show that the level of damage is similar in AD and normal lymphocytes and preliminary assays of the rate of repair suggest that the half-time is also similar, the value being > 1 h. The latter is consistent with the known rate of rejoining of chromosome fragments in interphase lymphocytes (Pantelias and Maillie 1985). (Author)

  2. Do instability markers predict satisfactory reduction and requirement for later surgery in emergency department patients with wrist fracture?

    Science.gov (United States)

    Winayak, Amar; Gossat, Alyza; Cooper, Jenny; Ritchie, Peter; Lim, Wei; Klim, Sharon; Kelly, Anne-Maree

    2018-02-01

    Research suggests that the presence of instability markers in patients with displaced distal radial fractures is associated with poorer outcome. Our aims were to determine whether the presence of previously defined instability markers could predict the likelihood of successful ED reduction and requirement for a secondary procedure after ED reduction. Retrospective cohort study performed by medical record review. Adult ED patients coded as having an isolated wrist fracture and having fracture reduction in ED were eligible for inclusion. Data collected included demographics, history of osteoporosis, mechanism of injury, radiological features on X-rays and performance of a secondary procedure. Outcomes of interest were the rate of successful fracture reduction in ED (against defined radiological criteria), the rate of secondary procedures and the association between the number of defined instability risk factors and successful reduction and performance of a secondary surgical procedure. Analysis was by χ 2 test, receiver operating characteristic curve, logistic regression analyses. Three hundred and nineteen patients were studied; median age 62 years, 77% female. Sixty-five per cent of patients had satisfactory fracture reduction in ED (95% CI 59%-70%). Eighty-six patients underwent a secondary procedure to reduce/stabilise their fracture (28%, 95% CI 23%-33%). Younger age, lack of satisfactory ED reduction and increased number of instability factors were independently predictive of the performance of a secondary procedure. Instability risk factors are common in patients with wrist fractures requiring reduction in ED. The number of instability factors is not a strong predictor of the performance of secondary procedures. © 2017 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  3. Neuropathic pain screening questionnaires have limited measurement properties. A systematic review.

    Science.gov (United States)

    Mathieson, Stephanie; Maher, Christopher G; Terwee, Caroline B; Folly de Campos, Tarcisio; Lin, Chung-Wei Christine

    2015-08-01

    The Douleur Neuropathique 4 (DN4), ID Pain, Leeds Assessment of Neuropathic Symptoms and Signs (LANSS), PainDETECT, and Neuropathic Pain Questionnaire have been recommended as screening questionnaires for neuropathic pain. This systematic review aimed to evaluate the measurement properties (eg, criterion validity and reliability) of these questionnaires. Online database searches were conducted and two independent reviewers screened studies and extracted data. Methodological quality of included studies and the measurement properties were assessed against established criteria. A modified Grading of Recommendations Assessment, Development and Evaluation approach was used to summarize the level of evidence. Thirty-seven studies were included. Most studies recruited participants from pain clinics. The original version of the DN4 (French) and Neuropathic Pain Questionnaire (English) had the most number of satisfactory measurement properties. The ID Pain (English) demonstrated satisfactory hypothesis testing and reliability, but all other properties tested were unsatisfactory. The LANSS (English) was unsatisfactory for all properties, except specificity. The PainDETECT (English) demonstrated satisfactory hypothesis testing and criterion validity. In general, the cross-cultural adaptations had less evidence than the original versions. Overall, the DN4 and Neuropathic Pain Questionnaire were most suitable for clinical use. These screening questionnaires should not replace a thorough clinical assessment. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  4. Rhythm-based heartbeat duration normalization for atrial fibrillation detection.

    Science.gov (United States)

    Islam, Md Saiful; Ammour, Nassim; Alajlan, Naif; Aboalsamh, Hatim

    2016-05-01

    Screening of atrial fibrillation (AF) for high-risk patients including all patients aged 65 years and older is important for prevention of risk of stroke. Different technologies such as modified blood pressure monitor, single lead ECG-based finger-probe, and smart phone using plethysmogram signal have been emerging for this purpose. All these technologies use irregularity of heartbeat duration as a feature for AF detection. We have investigated a normalization method of heartbeat duration for improved AF detection. AF is an arrhythmia in which heartbeat duration generally becomes irregularly irregular. From a window of heartbeat duration, we estimate the possible rhythm of the majority of heartbeats and normalize duration of all heartbeats in the window based on the rhythm so that we can measure the irregularity of heartbeats for both AF and non-AF rhythms in the same scale. Irregularity is measured by the entropy of distribution of the normalized duration. Then we classify a window of heartbeats as AF or non-AF by thresholding the measured irregularity. The effect of this normalization is evaluated by comparing AF detection performances using duration with the normalization, without normalization, and with other existing normalizations. Sensitivity and specificity of AF detection using normalized heartbeat duration were tested on two landmark databases available online and compared with results of other methods (with/without normalization) by receiver operating characteristic (ROC) curves. ROC analysis showed that the normalization was able to improve the performance of AF detection and it was consistent for a wide range of sensitivity and specificity for use of different thresholds. Detection accuracy was also computed for equal rates of sensitivity and specificity for different methods. Using normalized heartbeat duration, we obtained 96.38% accuracy which is more than 4% improvement compared to AF detection without normalization. The proposed normalization

  5. Coefficient of restitution of sports balls: A normal drop test

    International Nuclear Information System (INIS)

    Haron, Adli; Ismail, K A

    2012-01-01

    Dynamic behaviour of bodies during impact is investigated through impact experiment, the simplest being a normal drop test. Normally, a drop test impact experiment involves measurement of kinematic data; this includes measurement of incident and rebound velocity in order to calculate a coefficient of restitution (COR). A high speed video camera is employed for measuring the kinematic data where speed is calculated from displacement of the bodies. Alternatively, sensors can be employed to measure speeds, especially for a normal impact where there is no spin of the bodies. This paper compares experimental coefficients of restitution (COR) for various sports balls, namely golf, table tennis, hockey and cricket. The energy loss in term of measured COR and effects of target plate are discussed in relation to the material and construction of these sports balls.

  6. Double half-cone flap umbilicoplasty for proboscoid umbilical hernia in a 2 years old child with satisfactory results 2 years later.

    Science.gov (United States)

    Ashu, Eseme Ebai; Leroy, Guifo Marc; Aristide, Bang Guy; Joss, Bitang Mafok Louis; Bonaventure, Jemea; Patrick, Savom Eric; Myriam, Fotso Guegne

    2015-01-01

    Surgical repair of large umbilical hernias may present a challenging surgical problem; standard surgical techniques have proven to be inadequate for both closing the fascial defect of the umbilicus and providing a satisfactory cosmetic result. We describe here a case of double half-cone flap umbilicoplasty that was performed in a 2 years old boy. The case of a 2 years old child with proboscoid umbilical hernia. The protruding umbilical skin was excised sharply by two V-shaped cuts leaving two half cones, a short cephalic (0.5cm) and a long caudal (1cm). A classic herniotomy was carried out, with repair of the facial defect. The caudal half cone was sutured from its apex till half it's length upon itself with interrupted sutures and it was anchored deeply to the fascia. Then we inverted the cephalic half cone which was sutured to the caudal cone to form the new umbilicus. The early result was excellent with no complications and the result after 2years revealed a cosmetically satisfactory shape of the umbilicus. this technique provides a good solution for reconstruction of the protruding umbilical skin and it is easy to learn, easy to be taught and perform in surgical environments and may be applicable for any kind of umbilical reconstruction.

  7. Development of the apparatus for measuring magnetic properties of electrical steel sheets in arbitrary directions under compressive stress normal to their surface

    Science.gov (United States)

    Maeda, Yoshitaka; Urata, Shinya; Nakai, Hideo; Takeuchi, Yuuya; Yun, Kyyoul; Yanase, Shunji; Okazaki, Yasuo

    2017-05-01

    In designing motors, one must grasp the magnetic properties of electrical steel sheets considering actual conditions in motors. Especially important is grasping the stress dependence of magnetic power loss. This paper describes a newly developed apparatus to measure two-dimensional (2-D) magnetic properties (properties under the arbitrary alternating and the rotating flux conditions) of electrical steel sheets under compressive stress normal to the sheet surface. The apparatus has a 2-D magnetic excitation circuit to generate magnetic fields in arbitrary directions in the evaluation area. It also has a pressing unit to apply compressive stress normal to the sheet surface. During measurement, it is important to apply uniform stress throughout the evaluation area. Therefore, we have developed a new flux density sensor using needle probe method. It is composed of thin copper foils sputtered on electrical steel sheets. By using this sensor, the stress can be applied to the surface of the specimen without influence of this sensor. This paper described the details of newly developed apparatus with this sensor, and measurement results of iron loss by using are shown.

  8. Oxygen supplementation to stabilize preterm infants in the fetal to neonatal transition: no satisfactory answer.

    Directory of Open Access Journals (Sweden)

    Isabel eTorres-Cuevas

    2016-04-01

    Full Text Available Fetal life elapses in a relatively low oxygen environment. Immediately after birth with the initiation of breathing the lung expands and oxygen availability to tissue rises by twofold generating a physiologic oxidative stress. However, both lung anatomy and function and the antioxidant defense system do not mature until late in gestation and therefore very preterm infants often need respiratory support and oxygen supplementation in the delivery room to achieve postnatal stabilization. Notably, interventions in the first minutes of life can have long-lasting consequences. Recent trials have aimed to assess what initial inspiratory fraction of oxygen and what oxygen targets during this transitional period are best for extremely preterm infants based on the available nomogram. However, oxygen saturation nomogram informs only of term and late preterm infants but not on extremely preterm infants. Therefore, the solution to this conundrum may still have to wait before a satisfactory answer is available.

  9. Meta-analysis of Pentacam vs. ultrasound pachymetry in central corneal thickness measurement in normal, post-LASIK or PRK, and keratoconic or keratoconus-suspect eyes.

    Science.gov (United States)

    Wu, Wenjing; Wang, Yan; Xu, Lulu

    2014-01-01

    The aim of this meta-analysis is to evaluate the central corneal thickness (CCT) measurement differences between Pentacam (Oculus Inc., Germany) and Ultrasound Pachymetry (USP) in normal (unoperated eyes , myopic and astigmatic eyes without corneal disease or topographic irregularity), after laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK), and keratoconic or keratoconus suspected eyes. We assess whether Pentacam and USP have similar CCT differences in normal, thinner corneas after LASIK or PRK procedures, and kerotoconic or keratoconus suspected eyes. Data sources, including PubMed, Medline, EMBASE, and Cochrane Central Registry of Controlled Trials on the Cochrane Library, were searched to find the relevant studies. Primary outcome measures were CCT measurement between Pentacam and USP. Three groups of eyes were analyzed: normal; LASIK or PRK eyes; and keratoconus suspected or keratoconic eyes. Nineteen studies describing 1,908 eyes were enrolled in the normal group. Pentacam results were 1.47 μm ,95 % confidence interval (CI) -2.32 to 5.27, higher than USP without statistically significant difference (P = 0.45). Nine studies with total 539 eyes were included in the corneas after LASIK or PRK. The mean difference in the CCT measurement with Pentacam and ultrasound pachymetry was 1.03 μm, with the 95 % CI -3.36 to 5.42, there was no statistically difference (P = 0.64). Four studies with a total of 185 eyes were included in the keratoconic eyes or keratoconus-suspect group, however,the mean difference was -6.33 μm (95 % CI -9.17 to-3.49), which was statistically different between Pentacam and ultrasound pachymetry in the CCT measurement (P LASIK or PRK procedures. However, in keratoconic or keratoconus-suspect eyes, Pentacam slightly underestimates the central corneal thickness than does ultrasound pachymetry, which may result from the difficulty in fixation of keratoconic eyes, misalignment of Pentacam and the variation

  10. On reconciling ground-based with spaceborne normalized radar cross section measurements

    DEFF Research Database (Denmark)

    Baumgartner, Francois; Munk, Jens; Jezek, K C

    2002-01-01

    This study examines differences in the normalized radar cross section, derived from ground-based versus spaceborne radar data. A simple homogeneous half-space model, indicates that agreement between the two improves as 1) the distance from the scatterer is increased; and/or 2) the extinction...

  11. A signal normalization technique for illumination-based synchronization of 1,000-fps real-time vision sensors in dynamic scenes.

    Science.gov (United States)

    Hou, Lei; Kagami, Shingo; Hashimoto, Koichi

    2010-01-01

    To acquire images of dynamic scenes from multiple points of view simultaneously, the acquisition time of vision sensors should be synchronized. In this paper, an illumination-based synchronization derived from the phase-locked loop (PLL) mechanism based on the signal normalization method is proposed and evaluated. To eliminate the system dependency due to the amplitude fluctuation of the reference illumination, which may be caused by the moving objects or relative positional distance change between the light source and the observed objects, the fluctuant amplitude of the reference signal is normalized framely by the estimated maximum amplitude between the reference signal and its quadrature counterpart to generate a stable synchronization in highly dynamic scenes. Both simulated results and real world experimental results demonstrated successful synchronization result that 1,000-Hz frame rate vision sensors can be successfully synchronized to a LED illumination or its reflected light with satisfactory stability and only 28-μs jitters.

  12. A Signal Normalization Technique for Illumination-Based Synchronization of 1,000-fps Real-Time Vision Sensors in Dynamic Scenes

    Directory of Open Access Journals (Sweden)

    Koichi Hashimoto

    2010-09-01

    Full Text Available To acquire images of dynamic scenes from multiple points of view simultaneously, the acquisition time of vision sensors should be synchronized. In this paper, an illumination-based synchronization derived from the phase-locked loop (PLL mechanism based on the signal normalization method is proposed and evaluated. To eliminate the system dependency due to the amplitude fluctuation of the reference illumination, which may be caused by the moving objects or relative positional distance change between the light source and the observed objects, the fluctuant amplitude of the reference signal is normalized framely by the estimated maximum amplitude between the reference signal and its quadrature counterpart to generate a stable synchronization in highly dynamic scenes. Both simulated results and real world experimental results demonstrated successful synchronization result that 1,000-Hz frame rate vision sensors can be successfully synchronized to a LED illumination or its reflected light with satisfactory stability and only 28-μs jitters.

  13. Technegas - A new radiopharmaceutical for the measurement of gastric emptying in normal subjects

    Energy Technology Data Exchange (ETDEWEB)

    Kwiatek, M.A.; Jones, K.L. [University of South Australia, SA (Australia). School of Medical Radiation; Burch, W. [Tetley Medical, Lucas Heights, NSW (Australia); Horowitz, M.; Bartholomeusz, F.D.L. [Royal Adelaide Hospital, Adelaide, SA (Australia)

    1998-06-01

    Full text: Scintigraphy is now used widely to measure gastric emptying in humans. Both solid and liquid emptying should ideally be measured - most techniques employ test meals of minced beef and eggs. These meals are not always suitable for patients, especially those observing strict dietary regimens or vegetarians, in whom a vegetable-based meal such as rice is likely to be more acceptable. A previous study attempted to label rice with pertechnetate, but label stability was inadequate. The aim of this study was to determine whether Technegas could be used as a radioisotopic marker to assess gastric emptying of rice and liquids. The stability of Technegas rice was evaluated for three brands of rice by incubation in 0.9% saline, 1M HCI and simulated gastric fluid (3.2g/l pepsinogen, pH 2-4). The labelling stability of each type of rice after four hours was greater than 80%. Gastric emptying of 200g (370kcal) rice and 300ml (300kcal) dextrose drink, both labelled with approximately 20MBq of Technegas, was measured in eight normal subjects (6M, 2F) on two separate days. Venous blood samples were obtained for three hours after ingestion of the meal to quantify intestinal absorption of the radiolabel. Gastric emptying of rice was characterised by a lag phase followed by a linear emptying phase, while emptying of dextrose approximated a linear pattern after a short lag phase. The lag phase was longer for rice than dextrose (25{+-}7min vs 4{+-}2min; P<0.05), but there was no difference in the post lag emptying rate (2.1{+-}0.3kca/min vs 1.7{+-}0.2kcal/min; P=0.2), between the two meals. Intestinal absorption of the radiolabel increased over time, with a plateau after two hours; the total amount absorbed (5.3{+-}13% rice and 6.7{+-}1.8% dextrose) was small. These observations indicate that Technegas labelled rice and dextrose are suitable test meals for measurement of gastric emptying of solids and nutrient containing liquids

  14. Measurement and Analysis of Normal Zone Propagation in a ReBCO Coated Conductor at Temperatures Below 50K

    CERN Document Server

    van Nugteren, J; Wessel, S; Krooshoop, E; Nijhuis, A; ten Kate, H

    2015-01-01

    Measurements of the quasi-adiabatic normal zone propagation velocity and quench energies of a Superpower SCS4050 copper stabilised ReBCO superconducting tape are presented over a temperature range of 23 − 47 K; in parallel applied magnetic fields of 6, 10 and 14 T; and over a current range from 50% to 100% of Ic. The data are compared to results of analytic predictions and to one-dimensional numerical simulations. The availability of long lengths of ReBCO coated conductor makes the material interesting for many HTS applications operating well below the boiling point of liquid nitrogen, such as magnets and motors. One of the main issues in the design of such devices is quench detection and protection. At higher temperatures, the quench velocities in these materials are known to be about two orders of magnitude lower compared to low temperature superconductors, resulting in significantly smaller normal zones and the risk of higher peak temperatures. To investigate whether the same also holds for lower tempera...

  15. One-stage Revision ACL reconstruction with hamstring autograft results in satisfactory outcome

    Science.gov (United States)

    Kejriwal, Ritwik; Buelow, Jens

    2017-01-01

    Objectives: Revision anterior cruciate ligament (ACL) reconstruction is associated with poorer outcomes and higher rerupture rates when compared to primary ACL reconstruction. There is also a significant heterogeneity in surgical technique, number of stages, and graft options. We report a large single surgeon case series with hamstring autograft as a graft option. Methods: Observational series of revision ACL reconstructions performed by the senior author between 2005 and 2015 was carried out. Chart reviews and clinic follow-ups were performed with the following recorded – re-rupture rate, radiographic grading of osteoarthritis, KT-1000 arthrometer test, IKDC outcome scores and knee range of motion. All patients underwent single bundle four-strand hamstring autograft performed in one stage with use of new tunnels in majority of the cases. Results: 66 patients underwent hamstring autograft one-stage revision ACL reconstruction by Dr Jens Buelow. Chart review was carried out on all patients, and 26 (39%) were followed up in clinic and/or by phone with a mean follow up of 4.7 years. Outcomes included re-rupture rate of 4.5%, reoperation rate of 12%, mean visual analogue scale score of 7.6, mean side-to-side difference of 2.6 mm for KT-1000 arthrometer test, and mean IKDC score of 79. Of the 17 patients with radiographs, 40% had moderate osteoarthritis (grade 2 or 3) at follow-up. Conclusion: Revision ACL reconstruction can result in a satisfactory outcome when performed with a hamstring autograft in one stage.

  16. Quantitative Measurements of CH* Concentration in Normal Gravity and Microgravity Coflow Laminar Diffusion Flames

    Science.gov (United States)

    Giassi, D.; Cao, S.; Stocker, D. P.; Takahashi, F.; Bennett, B. A.; Smooke, M. D.; Long, M. B.

    2015-01-01

    With the conclusion of the SLICE campaign aboard the ISS in 2012, a large amount of data was made available for the analysis of the effect of microgravity on laminar coflow diffusion flames. Previous work focused on the study of sooty flames in microgravity as well as the ability of numerical models to predict its formation in a simplified buoyancy-free environment. The current work shifts the investigation to soot-free flames, putting an emphasis on the chemiluminescence emission from electronically excited CH (CH*). This radical species is of significant interest in combustion studies: it has been shown that the CH* spatial distribution is indicative of the flame front position and, given the relatively simple diagnostic involved with its measurement, several works have been done trying to understand the ability of CH* chemiluminescence to predict the total and local flame heat release rate. In this work, a subset of the SLICE nitrogen-diluted methane flames has been considered, and the effect of fuel and coflow velocity on CH* concentration is discussed and compared with both normal gravity results and numerical simulations. Experimentally, the spectral characterization of the DSLR color camera used to acquire the flame images allowed the signal collected by the blue channel to be considered representative of the CH* emission centered around 431 nm. Due to the axisymmetric flame structure, an Abel deconvolution of the line-of-sight chemiluminescence was used to obtain the radial intensity profile and, thanks to an absolute light intensity calibration, a quantification of the CH* concentration was possible. Results show that, in microgravity, the maximum flame CH* concentration increases with the coflow velocity, but it is weakly dependent on the fuel velocity; normal gravity flames, if not lifted, tend to follow the same trend, albeit with different peak concentrations. Comparisons with numerical simulations display reasonably good agreement between measured and

  17. Conductive Hearing Loss in Autistic, Learning-Disabled, and Normal Children.

    Science.gov (United States)

    Smith, Donald E. P.; And Others

    1988-01-01

    Repeated impedance measures were given over five weeks to 11 autistic, 20 learning-disabled, and 20 normal children. A repeated measures analysis of variance led to the conclusion that fluctuating, negative middle ear pressure greater than normal characterizes both autistic and learning-disabled children with the more abnormal pressures typical in…

  18. Why do measures of normal and disordered personality correlate? A study of genetic comorbidity.

    Science.gov (United States)

    Jang, K L; Livesley, W J

    1999-01-01

    The genetic and environmental correlations between measures of normal (NEO-FFI) and abnormal personality (Dimensional Assessment of Personality Pathology: DAPP-BQ) were estimated in a sample of 545 volunteer general population twin pairs (269 monozygotic and 276 dizygotic pairs). The largest genetic correlations were observed between the 18 DAPP-BQ dimensions and NEO-FFI neuroticism (range = .05 to .81; median = .48), extraversion (range = -.65 to .33; median = -.28), agreeableness (range = -.65 to .00; median = -.38), and conscientiousness (range = -.76 to .52; median = -.31). The smallest genetic correlations were found between the DAPP-BQ dimensions and NEO-FFI openness (range = -.17 to .20; median = -.04). The environmental correlations are lower in magnitude but show the same pattern of correlations between DAPP-BQ and NEO-FFI scales. These results indicate that these two scales share a common broad-based genetic architecture, whereas the environmental influences show greater scale specificity.

  19. Verbal Processing Reaction Times in "Normal" and "Poor" Readers.

    Science.gov (United States)

    Culbertson, Jack; And Others

    After it had been determined that reaction time (RT) was a sensitive measure of hemispheric dominance in a verbal task performed by normal adult readers, the reaction times of three groups of subjects (20 normal reading college students, 12 normal reading third graders and 11 poor reading grade school students) were compared. Ss were exposed to…

  20. Social Capital in Western and Eastern Europe: Method of Measurement

    DEFF Research Database (Denmark)

    Hjøllund, L.; Svendsen, Gert Tinggaard

    2000-01-01

    The purpose of this paper is to suggest a standard method of measurement for social capital. Various authors have investigated the influence of social capital on economic growth but still social capital has not been measured in any satisfactory way. So far, each survey has used its own ad hoc met...

  1. A study of normal and defective colour vision

    NARCIS (Netherlands)

    Bouman, M.A.; Walraven, P.L.

    1957-01-01

    MEASUREMENTS were made of saturation discrimination of normal and colour defective subjects with illuminant A as reference colour. The colorimeter used in the experiments was of a special design developed for easy use by untrained persons. The results for normals are not quite in agreement with the

  2. Approach for Text Classification Based on the Similarity Measurement between Normal Cloud Models

    Directory of Open Access Journals (Sweden)

    Jin Dai

    2014-01-01

    Full Text Available The similarity between objects is the core research area of data mining. In order to reduce the interference of the uncertainty of nature language, a similarity measurement between normal cloud models is adopted to text classification research. On this basis, a novel text classifier based on cloud concept jumping up (CCJU-TC is proposed. It can efficiently accomplish conversion between qualitative concept and quantitative data. Through the conversion from text set to text information table based on VSM model, the text qualitative concept, which is extraction from the same category, is jumping up as a whole category concept. According to the cloud similarity between the test text and each category concept, the test text is assigned to the most similar category. By the comparison among different text classifiers in different feature selection set, it fully proves that not only does CCJU-TC have a strong ability to adapt to the different text features, but also the classification performance is also better than the traditional classifiers.

  3. Satisfactory rate of postprocessing visualization of standard fetal cardiac views from 4-dimensional cardiac volumes acquired during routine ultrasound practice by experienced sonographers in peripheral centers.

    Science.gov (United States)

    Rizzo, Giuseppe; Capponi, Alessandra; Pietrolucci, Maria Elena; Capece, Giuseppe; Cimmino, Ernesto; Colosi, Enrico; Ferrentino, Salvatore; Sica, Carmine; Di Meglio, Aniello; Arduini, Domenico

    2011-01-01

    The aim of this study was to evaluate the feasibility of visualizing standard cardiac views from 4-dimensional (4D) cardiac volumes obtained at ultrasound facilities with no specific experience in fetal echocardiography. Five sonographers prospectively recorded 4D cardiac volumes starting from the 4-chamber view on 500 consecutive pregnancies at 19 to 24 weeks' gestation undergoing routine ultrasound examinations (100 pregnancies for each sonographer). Volumes were sent to the referral center, and 2 independent reviewers with experience in 4D fetal echocardiography assessed their quality in the display of the abdominal view, 4-chamber view, left and right ventricular outflow tracts, and 3-vessel and trachea view. Cardiac volumes were acquired in 474 of 500 pregnancies (94.8%). The 2 reviewers respectively acknowledged the presence of satisfactory images in 92.4% and 93.6% of abdominal views, 91.5% and 93.0% of 4-chamber views, in 85.0% and 86.2% of left ventricular outflow tracts, 83.9% and 84.5% of right ventricular outflow tracts, and 85.2% and 84.5% of 3-vessel and trachea views. The presence of a maternal body mass index of greater than 30 altered the probability of achieving satisfactory cardiac views, whereas previous maternal lower abdominal surgery did not affect the quality of reconstructed cardiac views. In conclusion, cardiac volumes acquired by 4D sonography in peripheral centers showed high enough quality to allow satisfactory diagnostic cardiac views.

  4. Generating a normalized geometric liver model with warping

    International Nuclear Information System (INIS)

    Boes, J.L.; Weymouth, T.E.; Meyer, C.R.; Quint, L.E.; Bland, P.H.; Bookstein, F.L.

    1990-01-01

    This paper reports on the automated determination of the liver surface in abdominal CT scans for radiation treatment, surgery planning, and anatomic visualization. The normalized geometric model of the liver is generated by averaging registered outlines from a set of 15 studies of normal liver. The outlines have been registered with the use of thin-plate spline warping based on a set of five homologous landmarks. Thus, the model consists of an average of the surface and a set of five anatomic landmarks. The accuracy of the model is measured against both the set of studies used in model generation and an alternate set of 15 normal studies with use of, as an error measure, the ratio of nonoverlapping model and study volume to total model volume

  5. Assessment of the ''thermal normalization technique'' for measurement of neutron cross sections vs energy

    International Nuclear Information System (INIS)

    Peelle, R.W.; de Sassure, G.

    1977-01-01

    Refined knowledge of the thermal neutron cross sections of the fissile nuclides and of the (n,α) reaction standards, together with the reasonably well known energy dependence of the latter, have permitted resonance-region and low-keV fissile nuclide cross sections to be based on these standards together with count-rate ratios observed as a function of energy using a pulsed ''white'' source. As one evaluates cross sections for energies above 20 keV, optimum results require combination of cross section shape measurements with all available absolute measurements. The assumptions of the ''thermal normalization method'' are reviewed, and an opinion is given of the status of some of the standards required for its use. The complications which may limit the accuracy of results using the method are listed and examples are given. For the 235 U(n,f) cross section, the option is discussed of defining resonance-region fission integrals as standards. The area of the approximately 9 eV resonances in this nuclide may be known to one percent accuracy, but at present the fission integral from 0.1 to 1.0 keV is known to no better than about two percent. This uncertainty is based on the scatter among independent results, and has not been reduced by the most recent measurements. This uncertainty now limits the accuracy attainable for the 235 U(n,f) cross section below about 50 keV. Suggestions are given to indicate how future detailed work might overcome past sources of error

  6. Normal values of the sagittal diameter of the lumbar spine (vertebral body and dural sac) in children measured by MRI

    International Nuclear Information System (INIS)

    Knirsch, Walter; Kurtz, Claudia; Langer, Mathias; Haeffner, Nicole; Kececioglu, Deniz

    2005-01-01

    The definition of normal values is a prerequisite for the reliable evaluation of abnormality in the lumbar spine, such as spinal canal stenosis or dural ectasia in patients with Marfan syndrome. Values for vertebral body diameter (VBD) and dural sac diameter (DSD) for the lumbar spine have been published in adults. In children, normal values have been established using conventional radiography or myelography, but not by MRI. To define normal values for the sagittal diameter of the vertebral body and dural sac, and to calculate a dural sac ratio (DSR) in the lumbosacral spine (L1-S1) in healthy children using MRI. A total of 75 healthy children between 6 years and 17 years of age were examined using a sagittal T2-weighted sequence. Sagittal VBD and DSD were measured and a DSR was calculated. This was a retrospective and cross-sectional study. With increasing age there is a significant increase of VBD, a slight increase of DSD, and a slight decrease of DSR. There is no significant sex difference. DSR in healthy children is higher than in healthy adults. MRI is a reliable method demonstrating the natural shape of the lumbosacral spine and its absolute values. These normal values compare well with those established by conventional radiological techniques. Our data may serve as a reference for defining dural ectasia in children with Marfan syndrome. (orig.)

  7. Normal values of the sagittal diameter of the lumbar spine (vertebral body and dural sac) in children measured by MRI

    Energy Technology Data Exchange (ETDEWEB)

    Knirsch, Walter [University Children' s Hospital Freiburg, Department of Pediatric Cardiology, Freiburg (Germany); University Children' s Hospital Zurich, Division of Paediatric Cardiology, Zurich (Switzerland); Kurtz, Claudia; Langer, Mathias [University Hospital Freiburg, Department of Radiology, Freiburg (Germany); Haeffner, Nicole; Kececioglu, Deniz [University Children' s Hospital Freiburg, Department of Pediatric Cardiology, Freiburg (Germany)

    2005-04-01

    The definition of normal values is a prerequisite for the reliable evaluation of abnormality in the lumbar spine, such as spinal canal stenosis or dural ectasia in patients with Marfan syndrome. Values for vertebral body diameter (VBD) and dural sac diameter (DSD) for the lumbar spine have been published in adults. In children, normal values have been established using conventional radiography or myelography, but not by MRI. To define normal values for the sagittal diameter of the vertebral body and dural sac, and to calculate a dural sac ratio (DSR) in the lumbosacral spine (L1-S1) in healthy children using MRI. A total of 75 healthy children between 6 years and 17 years of age were examined using a sagittal T2-weighted sequence. Sagittal VBD and DSD were measured and a DSR was calculated. This was a retrospective and cross-sectional study. With increasing age there is a significant increase of VBD, a slight increase of DSD, and a slight decrease of DSR. There is no significant sex difference. DSR in healthy children is higher than in healthy adults. MRI is a reliable method demonstrating the natural shape of the lumbosacral spine and its absolute values. These normal values compare well with those established by conventional radiological techniques. Our data may serve as a reference for defining dural ectasia in children with Marfan syndrome. (orig.)

  8. Numerical Analysis of a New Pressure Sensor for Measuring Normal and Tangential Stresses in the Roll Gap

    DEFF Research Database (Denmark)

    Presz, Wojtek P.; Wanheim, Tarras

    2003-01-01

    The paper is in polish. Orig. title: "Analiza numeryczna nowego czujnika do pomiaru nacisków i naprê¿eñ stycznych w procesie walcowania" A new strain gauge sensor for measuring normal and tangential stresses in the contact arc of a rolling process has been designed and constructed. The complicated...... load history of the sensor results in complicated deformation patterns of it, and consequently the calibration procedure of the sensor should cover a wide range of loading cases, and would thus be very difficult and time-consuming to carry out. As an alternative to this, a FEM simulative experiment has...

  9. SPM analysis of cerebrovascular reserve capacity after stimulation with acetazolamide measured by Tc-99m ECD SPECT in normal brain MRI patient

    Energy Technology Data Exchange (ETDEWEB)

    Lee, M. H.; Yoon, S. N.; Yoon, J. K.; Cho, C. W. [College of Medicine, Univ. of Ajou, Suwon (Korea, Republic of)

    2003-07-01

    This study was undertaken to evaluate normal response of acetazolamide in normal individuals, whose brain MRI is normal, using SPM99. In total, 10 Tc- 99m ECD brain SPECT were evaluated retrospectively. The half of the patients were male. Their mean age was 47.1 years old with a range of 33-61 years. They all visited our neurology department to evaluate stroke symptom. Their brain MRI was normal. Rest/acetazolamide brain SPECT was perfomed using Tc-99m ECD and the sequential injection and subtraction method. SPECT was acquired using fanbeam collimators and triple-head gamma camera (MultiSPECT III, Siemens medical systems, Inc. Hoffman Estates, III, USA). Chang's attenuation correction was applied their brain SPECT revealed normal rCBF pattern in visual analysis by two nuclear physician and they were diagnosed clinically normal. Using SPM method, we compared rest brain SPECT images with those of acetazolamide brain SPECT and measured the extent of the area with significant perfusion change (P<0.05) in predefined 34 cerebral regions. Acetazolamide brain SPECT showed no significant decreased region in comparison to rest brain SPECT. Only small portion of left mid temporal gyrus revealed increased rCBF on acetazolamide brain SPECT in comparison to rest brain SPECT. It apperas that there is no significant change in rCBF between rest and acetazolamide brain SPECT using Tc-99m ECD. The small number of this study is limitation of our study.

  10. CT and MRI normal findings

    International Nuclear Information System (INIS)

    Moeller, T.B.; Reif, E.

    1998-01-01

    This book gives answers to questions frequently heard especially from trainees and doctors not specialising in the field of radiology: Is that a normal finding? How do I decide? What are the objective criteria? The information presented is three-fold. The normal findings of the usual CT and MRI examinations are shown with high-quality pictures serving as a reference, with inscribed important additional information on measures, angles and other criteria describing the normal conditions. These criteria are further explained and evaluated in accompanying texts which also teach the systematic approach for individual picture analysis, and include a check list of major aspects, as a didactic guide for learning. The book is primarily intended for students, radiographers, radiology trainees and doctors from other medical fields, but radiology specialists will also find useful details of help in special cases. (orig./CB) [de

  11. Satisfactory spinal anesthesia with a total of 1.5 mg of bupivacaine for transurethral resection of bladder tumor in an elderly patient.

    Science.gov (United States)

    Namba, Yoshimichi; Yamakage, Michiaki; Tanaka, Yoshinori

    2016-01-01

    Spinal anesthesia is popular for endoscopic urological surgery. Many patients undergoing urological surgery are elderly. It is important to limit the dose to reduce any resultant hemodynamic effect. We present a case in which incremental administration of 0.1 % bupivacaine up to 1.5 mg was sufficient to produce satisfactory spinal anesthesia for transurethral resection of bladder tumor (TURBT).

  12. The COBE normalization for standard cold dark matter

    Science.gov (United States)

    Bunn, Emory F.; Scott, Douglas; White, Martin

    1995-01-01

    The Cosmic Background Explorer Satellite (COBE) detection of microwave anisotropies provides the best way of fixing the amplitude of cosmological fluctuations on the largest scales. This normalization is usually given for an n = 1 spectrum, including only the anisotropy caused by the Sachs-Wolfe effect. This is certainly not a good approximation for a model containing any reasonable amount of baryonic matter. In fact, even tilted Sachs-Wolfe spectra are not a good fit to models like cold dark matter (CDM). Here, we normalize standard CDM (sCDM) to the two-year COBE data and quote the best amplitude in terms of the conventionally used measures of power. We also give normalizations for some specific variants of this standard model, and we indicate how the normalization depends on the assumed values on n, Omega(sub B) and H(sub 0). For sCDM we find the mean value of Q = 19.9 +/- 1.5 micro-K, corresponding to sigma(sub 8) = 1.34 +/- 0.10, with the normalization at large scales being B = (8.16 +/- 1.04) x 10(exp 5)(Mpc/h)(exp 4), and other numbers given in the table. The measured rms temperature fluctuation smoothed on 10 deg is a little low relative to this normalization. This is mainly due to the low quadrupole in the data: when the quadrupole is removed, the measured value of sigma(10 deg) is quite consistent with the best-fitting the mean value of Q. The use of the mean value of Q should be preferred over sigma(10 deg), when its value can be determined for a particular theory, since it makes full use of the data.

  13. Does Excision of Heterotopic Ossification of the Elbow Result in Satisfactory Patient-Rated Outcomes?

    Science.gov (United States)

    Sandeep, K N; Suresh, G; Gopisankar, B; Abhishek, N; Sujiv, A

    2017-03-01

    Treatment of heterotopic ossification (HO) of the elbow is challenging and fraught with complications. Patients who sustain direct trauma to the elbow joint, the central nervous system, and thermal burns are at increased risk for development of HO. There is a paucity of studies and reports on patient's self-evaluation after the excision of the heterotopic ossification. This retrospective study assessed outcomes after excision of heterotopic ossification around the elbow in a cohort of ten patients operated from 2012 to 2015. The outcome assessment was done by the Mayo Elbow Performance index (MEPI) and the American Shoulder and Elbow Surgeons-Elbow score (ASES-E scores). The mean follow-up was 18.11 months after the operation. The Mayo Elbow Performance Score was excellent in two elbows, good in six and fair in two. The mean gain in flexion-extension arc after excision of HO was 80 degrees. All of the patients had residual flexion deformity postoperatively. Eight of the nine patients were able to do activities requiring flexion at final follow-up. Excision of HO around the elbow is associated with satisfactory patient-rated outcomes in spite of failure to regain full range of motion.

  14. Development of the apparatus for measuring magnetic properties of electrical steel sheets in arbitrary directions under compressive stress normal to their surface

    Directory of Open Access Journals (Sweden)

    Yoshitaka Maeda

    2017-05-01

    Full Text Available In designing motors, one must grasp the magnetic properties of electrical steel sheets considering actual conditions in motors. Especially important is grasping the stress dependence of magnetic power loss. This paper describes a newly developed apparatus to measure two-dimensional (2-D magnetic properties (properties under the arbitrary alternating and the rotating flux conditions of electrical steel sheets under compressive stress normal to the sheet surface. The apparatus has a 2-D magnetic excitation circuit to generate magnetic fields in arbitrary directions in the evaluation area. It also has a pressing unit to apply compressive stress normal to the sheet surface. During measurement, it is important to apply uniform stress throughout the evaluation area. Therefore, we have developed a new flux density sensor using needle probe method. It is composed of thin copper foils sputtered on electrical steel sheets. By using this sensor, the stress can be applied to the surface of the specimen without influence of this sensor. This paper described the details of newly developed apparatus with this sensor, and measurement results of iron loss by using are shown.

  15. Serum hepatitis B core-related antigen is a satisfactory surrogate marker of intrahepatic covalently closed circular DNA in chronic hepatitis B.

    Science.gov (United States)

    Chen, En-Qiang; Feng, Shu; Wang, Meng-Lan; Liang, Ling-Bo; Zhou, Ling-Yun; Du, Ling-Yao; Yan, Li-Bo; Tao, Chuan-Min; Tang, Hong

    2017-03-14

    Recently, hepatitis B core-related antigen (HBcrAg) has been suggested as an additional marker of hepatitis B virus (HBV) infection. This study aimed to investigate whether serum quantitative HBcrAg (qHBcrAg) was a satisfactory surrogate marker of intrahepatic covalently closed circular DNA (cccDNA). A total of 139 patients with liver biopsy were enrolled, consisting of 59 patients in immune tolerance (IT) phase, 52 patients in immune clearance (IC) phase, 18 patients in low-replication (LR) phase, and 10 patients in reactivation phase. All patients in IC phase have received entecavir (ETV) therapy, and 32 of them undergone a second liver biopsy at 24 months. Among those patients, qHBcrAg was strongly correlated with intrahepatic cccDNA, which is superior to that of qHBsAg and HBV DNA. And similar findings were also observed in patients in IT, IC, LR and reactivation phases. Among the 32 ETV-treated patients with a second liver biopsy in IC phase, the decline of intrahepatic cccDNA was accompanied by changes in both qHBcrAg and qHBsAg. However, as compared to qHBsAg, the change of qHBcrAg was more strongly associated with intrahepatic cccDNA-decline. In summary, serum qHBcrAg should be a satisfactory surrogate of intrahepatic HBV cccDNA in CHB patients.

  16. Normal-zone detectors for the MFTF-B coils. Revision 1

    International Nuclear Information System (INIS)

    Owen, E.W.; Shimer, D.W.

    1983-01-01

    In order to protect a set of inductively coupled superconducting magnets, it is necessary to locate and measure normal zone voltages that are small compared with the mutual and self-induced voltages. The method described in this report uses two sets of voltage measurements to locate and measure one or more normal zones in any number of coupled coils. One set of voltages is the outputs of bridges that balance out the self-induced voltages. The other set of voltages can be the voltages across the coils, although alternatives are possible. The two sets of equations form a single combined set of equations. Each normal zone location or combination of normal zones has a set of these combined equations associated with it. It is demonstrated that the normal zone can be located and the correct set chosen, allowing determination of the size of the normal zone. Only a few operations take place in a working detector: multiplication of a constant, addition, and simple decision-making. In many cases the detector for each coil, although weakly linked to the other detectors, can be considered to be independent. An example of the detector design is given for four coils with realistic parameters. The effect on accuracy of changes in the system parameters is discussed

  17. Proton backscatter as a means of mass normalization in PIXE scanning of human hair

    International Nuclear Information System (INIS)

    Russell, S.B.; Gibson, R.S.; Faiq, S.; Campbell, J.L.

    1981-01-01

    Variations in linear density along a given hair can cause changes in X-ray intensity which do not reflect elemental concentration changes. Hairs from different subjects vary by a factor approx. 5 in linear density, so that very different X-ray intensities need not necessarily reflect different concentrations. We investigate the usefulness of the backscattered proton intensity as a means of determining the mass undergoing PIXE analysis. Specimen damage can be avoided in the BS measurement via low currents without loss of statistics. A correlation is found between BS intensity and mass, but a laser diffraction measurement of the hair diameter provides an equally satisfactory mass determination. (orig.)

  18. Reduction in mean cerebral blood flow measurements using {sup 99m}Tc-ECD-SPECT during normal aging

    Energy Technology Data Exchange (ETDEWEB)

    Kawahata, Nobuya; Daitoh, Nobuyuki; Shirai, Fumie; Hara, Shigeru [Narita Memorial Hospital, Toyohashi, Aichi (Japan)

    1997-10-01

    Mean cerebral blood flow (mCBF) was measured by SPECT using the {sup 99m}Tc-ECD-Patlak-Plot method in a selected group of 61 normal non-hospitalized subjects aged 51 to 91 years. The mCBF values showed 48.4{+-}4.7 ml/100 g/min in aged 50-59 years group, 49.9{+-}5.9 ml/100 g/min in aged 60-69 years group, 46.4 {+-}6.5 ml/100 g/min in aged 70-79 group, 38.0{+-}3.7 ml/100 g/min in aged 80-89 years group, 38.9 ml/100 g/min in aged 90-99 years group. There was a statistically significant reduction of mCBF with advancing age (R=-0.41; p=0.001). Women have significantly higher mCBF values than men up to aged 70 years group. In this study, there was no significant laterality in the mCBF between right and left hemispheres in all decade groups. The history of hypertension, alcohol consumption, and cigarette smoking failed to show significant difference in the mCBF values. The present study shows that normal aging is associated with mCBF reduction. (author)

  19. Association of Anthropometric Measures with Cardiovascular Risk Factors and Metabolic Syndrome in Normal-Weight Children and Adolescents: The CASPIAN III Study

    Directory of Open Access Journals (Sweden)

    Mostafa Qorbani

    2013-10-01

    Full Text Available Objective: This nationwide study was conducted to determine the association of anthropometric measures with cardiovascular risk factors and metabolic syndrome (MetS in Iranian normal-weight children and adolescents. Methods: We analyzed the data of 3,565 children and adolescents (50.3% boys, aged 10-18 years, with a normal BMI (5th-84th percentile obtained from the third survey of ‘Childhood and Adolescence Surveillance and Prevention of Adult Non-communicable Disease' (CASPIAN III study. The diagnostic criteria for MetS were defined by the International Diabetes Federation consensus. Results: The prevalence of MetS for 10- to 13.9-year-old boys, 14- to 18-year-old boys, 10- to 13.9-year-old girls, and 14- to 18-year-old girls were 1.4, 2.8, 2.3, and 3.3%, respectively. After adjustment for age and sex, each unit increase in BMI (within normal range and waist circumference increased the odds of MetS from 6 to 72% and from 1 to 20%, respectively. The dominant pattern of dyslipidemia among the participants was high triglycerides and low high-density lipoprotein cholesterol. Conclusion: This study complements recent research about the high frequency of metabolic risk factors among normal-weight individuals in the pediatric age group.

  20. GABA-A stimulation in normal volunteers and during temporal epilepsy measured by 18FDG with positron emission tomography

    International Nuclear Information System (INIS)

    Cinotti, L.; Le Bars, D.; Garcia-Larrea, L.; Peyron, R.; Gregoire, M.C.; Lavenne, F.; Comar, D.; Mauguiere, F.; Krogsgaard-Larsen, P.

    1996-01-01

    The γ-amino butyric acid (GABA) is the principal inhibitory neurotransmitter of the brain and it has been evoked in epilepto-genesis. Using a GABA analog, the THIP, we tried to establish if the gabaergic neurotransmission was modified in the epileptic focus. For this purpose, we measured the effects of this specific GABA agonist on the cerebral glucose consumption (CMRGlu) as measured by 18F-fluoro-deoxyglucose ( 18 FDG) with positron emission tomography (PET). Eight patients presenting temporal epilepsy and three normal volunteers received two 18 FDG PET studies, after placebo and THIP injection, in random order. Clinical symptoms and electroencephalographic data demonstrated a trend towards sleepiness and a diminution of alpha waves after THIP injection. CMRGlu was globally increased with THIP in cortical regions, cerebellum and caudate nuclei. The average increase was 17% in grey matter while it did not reach significancy in white matter. Under the placebo condition, the asymmetry between the focus and the controlateral internal temporal zone was 18% as an average, and reduced significantly to 11% after THIP injection. In the external temporal zones, the asymmetry decreased from 28% to 14%. These results suggest that gabaergic inhibition requires energy in the normal brain tissue and in this with temporal epilepsy. Since the asymmetry of glucose consumption tends to diminish, the inhibitory GABA system appears preserved in temporal epilepsy with an enhanced sensitivity in the focus. (Authors). 6 refs., 4 figs

  1. DNA measurements on cell nuclei of normal, proliferating and neoplastic thyroid tissues in rats

    International Nuclear Information System (INIS)

    Christov, K.; Thomas, C.; Sandritter, W.

    1975-01-01

    Nuclear DNA content was measured in 3 normal, 9 hyperplastic and 16 neoplastic rat thyroid glands. Thyroid hyperplasia and tumor growth were induced after treatment of the animals with X rays and methylthiouracil. In the control animals only diploid thyroid epithelial cells were observed. In stages of diffuse and nodular thyroid hyperplasia, the total DNA content per nucleus indicated that most chromosomes were diploid; only a few cells were hyperdiploid. In thyroid adenomas and carcinomas scattering of the diploid region and an increased number of hyperdiploid cells were found. Among the various types of thyroid tumors neither a difference in the number of hyperdiploid cells, nor the typical pattern of the distribution of these cells in a histogram was found. The increased number of hyperdiploid cells in hyperplastic and neoplastic thyroids only suggested an increase in the proportion of cells entering the cell cycle and not an appearance of a neoplastic strain. (author)

  2. DNA measurements on cell nuclei of normal, proliferating and neoplastic thyroid tissues in rats

    Energy Technology Data Exchange (ETDEWEB)

    Christov, K [National Center of Oncology, Academy of Medicine, Sofia-56 (Bulgaria); Thomas, C; Sandritter, W [Freiburg Univ. (F.R. Germany). Pathologisches Inst.

    1975-01-01

    Nuclear DNA content was measured in 3 normal, 9 hyperplastic and 16 neoplastic rat thyroid glands. Thyroid hyperplasia and tumor growth were induced after treatment of the animals with X rays and methylthiouracil. In the control animals only diploid thyroid epithelial cells were observed. In stages of diffuse and nodular thyroid hyperplasia, the total DNA content per nucleus indicated that most chromosomes were diploid; only a few cells were hyperdiploid. In thyroid adenomas and carcinomas scattering of the diploid region and an increased number of hyperdiploid cells were found. Among the various types of thyroid tumors neither a difference in the number of hyperdiploid cells, nor the typical pattern of the distribution of these cells in a histogram was found. The increased number of hyperdiploid cells in hyperplastic and neoplastic thyroids only suggested an increase in the proportion of cells entering the cell cycle and not an appearance of a neoplastic strain.

  3. CT assessment of normal splenic size in children

    International Nuclear Information System (INIS)

    Prassopoulos, P.; Cavouras, D.

    1994-01-01

    The size of the normal spleen was estimated by CT in 153 children, examined with indication unrelated to splenic disease. In each patient the width, thickness, length and volume of the spleen were calculated. Measurements were also normalized to the transverse diameter of the body of the first lumbar vertebra. The spleen underwent significant growth during the first 4 years of life and reached maximum size at the age of 13. There were no differences in splenic volume between boys and girls. Splenic thickness correlated best with normal splenic volume. The strongest correlation was also found between splenic thickness and volume in a group of 45 children with clinically evident splenomegaly. Splenic thickness, an easy-to-use measurement, may be employed in everyday practice to represent splenic volume on CT. (orig.)

  4. An investigation on normal school students’ learning burnout – A case study of English normal students

    Directory of Open Access Journals (Sweden)

    Linjing Xu

    2017-11-01

    Full Text Available Learning burnout is a phenomenon in which students hold a negative attitude to curriculum learning, which manifests in aspects of physiology, psychology, behavior and interpersonal communication. China attaches great importance to higher education, colleges and universities shoulder the important task of training national modernization personnel. The problem of university students’ learning burnout has become a social phenomenon that cannot be ignored. Normal university students are one of the important groups of college students, and this phenomenon of learning burnout may also occur among them. English majors are the backbone of English teachers in primary and secondary schools in the future. The learning status of these groups affects the overall quality of teaching in normal colleges and universities and, more importantly, the quality of teachers in primary and secondary schools in the future. This paper first reviews the definition of learning burnout and the research methods of measurement. Subsequently, it investigates the learning burnout of English matriculation students by taking the first-year English majors of Jiangxi Normal University as an example. In this way, this research is hoped to promote the study on learning burnout not only among English normal students but also other normal students.

  5. Carotid artery intima-media thickness measurement in children with normal and increased body mass index: a comparison of three techniques.

    Science.gov (United States)

    El Jalbout, Ramy; Cloutier, Guy; Cardinal, Marie-Hélène Roy; Henderson, Mélanie; Lapierre, Chantale; Soulez, Gilles; Dubois, Josée

    2018-05-09

    Common carotid artery intima-media thickness is a marker of subclinical atherosclerosis. In children, increased intima-media thickness is associated with obesity and the risk of cardiovascular events in adulthood. To compare intima-media thickness measurements using B-mode ultrasound, radiofrequency (RF) echo tracking, and RF speckle probability distribution in children with normal and increased body mass index (BMI). We prospectively measured intima-media thickness in 120 children randomly selected from two groups of a longitudinal cohort: normal BMI and increased BMI, defined by BMI ≥85th percentile for age and gender. We followed Mannheim recommendations. We used M'Ath-Std for automated B-mode imaging, M-line processing of RF signal amplitude for RF echo tracking, and RF signal segmentation and averaging using probability distributions defining image speckle. Statistical analysis included Wilcoxon and Mann-Whitney tests, and Pearson correlation coefficient and intra-class correlation coefficient (ICC). Children were 10-13 years old (mean: 11.7 years); 61% were boys. The mean age was 11.4 years (range: 10.0-13.1 years) for the normal BMI group and 12.0 years (range: 10.1-13.5 years) for the increased BMI group. The normal BMI group included 58% boys and the increased BMI group 63% boys. RF echo tracking method was successful in 79 children as opposed to 114 for the B-mode method and all 120 for the probability distribution method. Techniques were weakly correlated: ICC=0.34 (95% confidence interval [CI]: 0.27-0.39). Intima-media thickness was significantly higher in the increased BMI than normal BMI group using the RF techniques and borderline for the B-mode technique. Mean differences between weight groups were: B-mode, 0.02 mm (95% CI: 0.00 to 0.04), P=0.05; RF echo tracking, 0.03 mm (95% CI: 0.01 to 0.05), P=0.01; and RF speckle probability distribution, 0.03 mm (95% CI: 0.01 to 0.05), P=0.002. Though techniques are not interchangeable, all showed

  6. Normal Development and Measurements of the Occipital Condyle-C1 Interval in Children and Young Adults.

    Science.gov (United States)

    Smith, P; Linscott, L L; Vadivelu, S; Zhang, B; Leach, J L

    2016-05-01

    Widening of the occipital condyle-C1 interval is the most specific and sensitive means of detecting atlanto-occipital dislocation. Recent studies attempting to define normal measurements of the condyle-C1 interval in children have varied substantially. This study was performed to test the null hypothesis that condyle-C1 interval morphology and joint measurements do not change as a function of age. Imaging review of subjects undergoing CT of the upper cervical spine for reasons unrelated to trauma or developmental abnormality was performed. Four equidistant measurements were obtained for each bilateral condyle-C1 interval on sagittal and coronal images. The cohort was divided into 7 age groups to calculate the mean, SD, and 95% CIs for the average condyle-C1 interval in both planes. The prevalence of a medial occipital condyle notch was calculated. Two hundred forty-eight joints were measured in 124 subjects with an age range of 2 days to 22 years. The condyle-C1 interval varies substantially by age. Average coronal measurements are larger and more variable than sagittal measurements. The medial occipital condyle notch is most prevalent from 1 to 12 years and is uncommon in older adolescents and young adults. The condyle-C1 interval increases during the first several years of life, is largest in the 2- to 4-year age range, and then decreases through late childhood and adolescence. A single threshold value to detect atlanto-occipital dissociation may not be sensitive and specific for all age groups. Application of this normative data to documented cases of atlanto-occipital injury is needed to determine clinical utility. © 2016 by American Journal of Neuroradiology.

  7. Relating normalization to neuronal populations across cortical areas.

    Science.gov (United States)

    Ruff, Douglas A; Alberts, Joshua J; Cohen, Marlene R

    2016-09-01

    Normalization, which divisively scales neuronal responses to multiple stimuli, is thought to underlie many sensory, motor, and cognitive processes. In every study where it has been investigated, neurons measured in the same brain area under identical conditions exhibit a range of normalization, ranging from suppression by nonpreferred stimuli (strong normalization) to additive responses to combinations of stimuli (no normalization). Normalization has been hypothesized to arise from interactions between neuronal populations, either in the same or different brain areas, but current models of normalization are not mechanistic and focus on trial-averaged responses. To gain insight into the mechanisms underlying normalization, we examined interactions between neurons that exhibit different degrees of normalization. We recorded from multiple neurons in three cortical areas while rhesus monkeys viewed superimposed drifting gratings. We found that neurons showing strong normalization shared less trial-to-trial variability with other neurons in the same cortical area and more variability with neurons in other cortical areas than did units with weak normalization. Furthermore, the cortical organization of normalization was not random: neurons recorded on nearby electrodes tended to exhibit similar amounts of normalization. Together, our results suggest that normalization reflects a neuron's role in its local network and that modulatory factors like normalization share the topographic organization typical of sensory tuning properties. Copyright © 2016 the American Physiological Society.

  8. Technegas - A new radiopharmaceutical for the measurement of gastric emptying in normal subjects

    International Nuclear Information System (INIS)

    Kwiatek, M.A.; Jones, K.L.; Horowitz, M.; Bartholomeusz, F.D.L.

    1998-01-01

    Full text: Scintigraphy is now used widely to measure gastric emptying in humans. Both solid and liquid emptying should ideally be measured - most techniques employ test meals of minced beef and eggs. These meals are not always suitable for patients, especially those observing strict dietary regimens or vegetarians, in whom a vegetable-based meal such as rice is likely to be more acceptable. A previous study attempted to label rice with pertechnetate, but label stability was inadequate. The aim of this study was to determine whether Technegas could be used as a radioisotopic marker to assess gastric emptying of rice and liquids. The stability of Technegas rice was evaluated for three brands of rice by incubation in 0.9% saline, 1M HCI and simulated gastric fluid (3.2g/l pepsinogen, pH 2-4). The labelling stability of each type of rice after four hours was greater than 80%. Gastric emptying of 200g (370kcal) rice and 300ml (300kcal) dextrose drink, both labelled with approximately 20MBq of Technegas, was measured in eight normal subjects (6M, 2F) on two separate days. Venous blood samples were obtained for three hours after ingestion of the meal to quantify intestinal absorption of the radiolabel. Gastric emptying of rice was characterised by a lag phase followed by a linear emptying phase, while emptying of dextrose approximated a linear pattern after a short lag phase. The lag phase was longer for rice than dextrose (25±7min vs 4±2min; P<0.05), but there was no difference in the post lag emptying rate (2.1±0.3kca/min vs 1.7±0.2kcal/min; P=0.2), between the two meals. Intestinal absorption of the radiolabel increased over time, with a plateau after two hours; the total amount absorbed (5.3±13% rice and 6.7±1.8% dextrose) was small. These observations indicate that Technegas labelled rice and dextrose are suitable test meals for measurement of gastric emptying of solids and nutrient containing liquids

  9. Model-based normalization for iterative 3D PET image

    International Nuclear Information System (INIS)

    Bai, B.; Li, Q.; Asma, E.; Leahy, R.M.; Holdsworth, C.H.; Chatziioannou, A.; Tai, Y.C.

    2002-01-01

    We describe a method for normalization in 3D PET for use with maximum a posteriori (MAP) or other iterative model-based image reconstruction methods. This approach is an extension of previous factored normalization methods in which we include separate factors for detector sensitivity, geometric response, block effects and deadtime. Since our MAP reconstruction approach already models some of the geometric factors in the forward projection, the normalization factors must be modified to account only for effects not already included in the model. We describe a maximum likelihood approach to joint estimation of the count-rate independent normalization factors, which we apply to data from a uniform cylindrical source. We then compute block-wise and block-profile deadtime correction factors using singles and coincidence data, respectively, from a multiframe cylindrical source. We have applied this method for reconstruction of data from the Concorde microPET P4 scanner. Quantitative evaluation of this method using well-counter measurements of activity in a multicompartment phantom compares favourably with normalization based directly on cylindrical source measurements. (author)

  10. Some practical aspects of peak kilovoltage measurements

    International Nuclear Information System (INIS)

    Irfan, A.Y.; Pugh, V.I.; Jeffery, C.D.

    1985-01-01

    The peak kilovoltage (kVsub(p)) across the X-ray tube electrodes in diagnostic X-ray machines is a most important parameter, affecting both radiation output and beam quality. Four commercially available non-invasive devices used for kVsub(p) measurement were tested using a selection of generator waveforms. The majority of the devices provided satisfactory measurements of the kVsub(p) to within approximately +- kV provided certain operating conditions are observed. (U.K.)

  11. Normal zone detectors for a large number of inductively coupled coils

    International Nuclear Information System (INIS)

    Owen, E.W.; Shimer, D.W.

    1983-01-01

    In order to protect a set of inductively coupled superconducting magnets, it is necessary to locate and measure normal zone voltages that are small compared with the mutual and self-induced voltages. The method described in this paper uses two sets of voltage measurements to locate and measure one or more normal zones in any number of coupled coils. One set of voltages is the outputs of bridges that balance out the self-induced voltages. The other set of voltages can be the voltages across the coils, although alternatives are possible. The two sets of equations form a single combined set of equations. Each normal zone location or combination of normal zones has a set of these combined equations associated with it. It is demonstrated that the normal zone can be located and the correct set chosen, allowing determination of the size of the normal zone. Only a few operations take place in a working detector: multiplication of a constant, addition, and simple decision-making. In many cases the detector for each coil, although weakly linked to the other detectors, can be considered to be independent

  12. Comparison of image quality and visibility of normal and abnormal findings at submillisievert chest CT using filtered back projection, iterative model reconstruction (IMR) and iDose{sup 4}™

    Energy Technology Data Exchange (ETDEWEB)

    Laqmani, Azien, E-mail: a.laqmani@uke.de [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Avanesov, Maxim; Butscheidt, Sebastian; Kurfürst, Maximilian [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Sehner, Susanne [Department of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Schmidt-Holtz, Jakob; Derlin, Thorsten; Behzadi, Cyrus [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Nagel, Hans D. [Science & Technology for Radiology, Fritz-Reuter-Weg 5f, 21244 Buchholz, Germany, (Germany); Adam, Gerhard; Regier, Marc [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany)

    2016-11-15

    Objective: To compare both image quality and visibility of normal and abnormal findings at submillisievert chest CT (smSv-CT) using filtered back projection (FBP) and the two different iterative reconstruction (IR) techniques iterative model reconstruction (IMR) and iDose{sup 4}™. Materials and methods: This institutional review board approved study was based on retrospective interpretation of clinically indicated acquired data. The requirement to obtain informed consent was waived. 81 patients with suspected pneumonia underwent smSv-CT (Brilliance iCT, Philips Healthcare; mean effective dose: 0.86 ± 0.2 mSv). Data were reconstructed using FBP and two different IR techniques iDose{sup 4}™ and IMR (Philips Healthcare) at various iteration levels. Objective image noise (OIN) was measured. Two experienced readers independently assessed all images for image noise, image appearance and visibility of normal anatomic and abnormal findings. A random intercept model was used for statistical analysis. Results: Compared to FBP and iDose{sup 4}™, IMR reduced OIN up to 88% and 72%, respectively (p < 0.001). A mild blotchy image appearance was seen in IMR images, affecting diagnostic confidence. iDose{sup 4}™ images provided satisfactory to good image quality for visibility of normal and abnormal findings and were superior to FBP (p < 0.001). IMR images were significantly inferior for visibility of normal structures compared to iDose{sup 4}™, while being superior for visibility of abnormal findings except for reticular pattern (p < 0.001). Conclusion: IMR results for visibility of normal and abnormal lung findings are heterogeneous, indicating that IMR may not represent a priority technique for clinical routine. iDose{sup 4}™ represents a suitable method for evaluation of lung tissue at submillisievert chest CT.

  13. Normal distribution of standing balance for healthy Danish children

    DEFF Research Database (Denmark)

    Pedersen, Line Kjeldgaard; Ghasemi, Habib; Rahbek, Ole

    2013-01-01

    Title: Normal distribution of standing balance for healthy Danish children – Reproducibility of parameters of balance. Authors Line Kjeldgaard Pedersen Habib Ghasemi Ole Rahbek Bjarne Møller-Madsen 1800 characters incl. spaces Background Pedobarographic measurements are increasingly used in child......Title: Normal distribution of standing balance for healthy Danish children – Reproducibility of parameters of balance. Authors Line Kjeldgaard Pedersen Habib Ghasemi Ole Rahbek Bjarne Møller-Madsen 1800 characters incl. spaces Background Pedobarographic measurements are increasingly used...

  14. 13C-octanoic acid breath test for measurement of solid gastric emptying: reproducibility in normal subjects and patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Feng Bo; Dan, Z.

    2001-01-01

    Objective: To examine the intra-individual reproducibility of the octanoic acid breath test in normal subjects and diabetics and to investigate whether cardiovascular autonomic neuropathy and delayed gastric emptying influence the intra-individual reproducibility. Methods: Nine normal subjects (six men, three women,mean age 38 years) and 15 diabetics with insulin treatment [nine men, six women; mean age 47 years; six had cardiovascular autonomic diabetic neuropathy (CADN) and/or delayed gastric emptying time] were, after a nocturnal fasting period, given a standard test meal (labelled with 13 C-octanoic acid, 1 046 kJ). Breath samples were taken at ten minute intervals over first one hour and at fifteen minute intervals over the following three hours and examined for 13 CO 2 by isotope ratio infrared spectrometry. Using a regression method gastric emptying half times (t 1/2 ) and lag phase (t lag ) were determined. Results: There was not a significant difference of t 1/2 and t lag between two measurements in normal subjects and diabetics. The coefficients of variation of day-to-day reproducibility were 11.7% for t 1/2 , 19.4% for t lag in normal subjects and 17.8% for t 1/2 , 28.2% for t lag in diabetics, but there was not significant difference between normal subjects and diabetics. There was not significant difference of intra-individual coefficient of variation of t 1/2 and t lag between diabetics with/without CADN and between diabetics with normal gastric emptying time and diabetics with delayed gastric emptying time. Conclusions: The 13 C-octanoic acid breath test has a high intra-individual reproducibility which is not affected by the cardiovascular autonomic neuropathy and delayed gastric emptying. It can be recommended as a non-invasive test for assessing gastric emptying time after a solid test meal in diabetics

  15. A new normalization method based on electrical field lines for electrical capacitance tomography

    International Nuclear Information System (INIS)

    Zhang, L F; Wang, H X

    2009-01-01

    Electrical capacitance tomography (ECT) is considered to be one of the most promising process tomography techniques. The image reconstruction for ECT is an inverse problem to find the spatially distributed permittivities in a pipe. Usually, the capacitance measurements obtained from the ECT system are normalized at the high and low permittivity for image reconstruction. The parallel normalization model is commonly used during the normalization process, which assumes the distribution of materials in parallel. Thus, the normalized capacitance is a linear function of measured capacitance. A recently used model is a series normalization model which results in the normalized capacitance as a nonlinear function of measured capacitance. The newest presented model is based on electrical field centre lines (EFCL), and is a mixture of two normalization models. The multi-threshold method of this model is presented in this paper. The sensitivity matrices based on different normalization models were obtained, and image reconstruction was carried out accordingly. Simulation results indicate that reconstructed images with higher quality can be obtained based on the presented model

  16. Power curve report - with turbulence intensity normalization

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Wagner, Rozenn; Vesth, Allan

    , additional shear and turbulence intensitity filters are applied on the measured data. Secondly, the method for normalization to a given reference turbulence intensity level (as described in Annex M of the draft of IEC 61400-12-1 Ed.2 [3]) is applied. The measurements have been performed using DTU...

  17. Optimal preparation-to-colonoscopy interval in split-dose PEG bowel preparation determines satisfactory bowel preparation quality: an observational prospective study.

    Science.gov (United States)

    Seo, Eun Hee; Kim, Tae Oh; Park, Min Jae; Joo, Hee Rin; Heo, Nae Yun; Park, Jongha; Park, Seung Ha; Yang, Sung Yeon; Moon, Young Soo

    2012-03-01

    Several factors influence bowel preparation quality. Recent studies have indicated that the time interval between bowel preparation and the start of colonoscopy is also important in determining bowel preparation quality. To evaluate the influence of the preparation-to-colonoscopy (PC) interval (the interval of time between the last polyethylene glycol dose ingestion and the start of the colonoscopy) on bowel preparation quality in the split-dose method for colonoscopy. Prospective observational study. University medical center. A total of 366 consecutive outpatients undergoing colonoscopy. Split-dose bowel preparation and colonoscopy. The quality of bowel preparation was assessed by using the Ottawa Bowel Preparation Scale according to the PC interval, and other factors that might influence bowel preparation quality were analyzed. Colonoscopies with a PC interval of 3 to 5 hours had the best bowel preparation quality score in the whole, right, mid, and rectosigmoid colon according to the Ottawa Bowel Preparation Scale. In multivariate analysis, the PC interval (odds ratio [OR] 1.85; 95% CI, 1.18-2.86), the amount of PEG ingested (OR 4.34; 95% CI, 1.08-16.66), and compliance with diet instructions (OR 2.22l 95% CI, 1.33-3.70) were significant contributors to satisfactory bowel preparation. Nonrandomized controlled, single-center trial. The optimal time interval between the last dose of the agent and the start of colonoscopy is one of the important factors to determine satisfactory bowel preparation quality in split-dose polyethylene glycol bowel preparation. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  18. Whole-body bone mineral content, lean body mass, and fat mass measured by dual-energy x-ray absorptiometry in a population of normal Canadian children and adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Sala, A. [McMaster Children' s Hospital, Hamilton, Ontario (Canada); McMaster Univ., Dept. of Pediatrics, Hamilton, Ontario (Canada); Univ. of Milan-Bicocca, Monza (Italy); Webber, C.E. [Hamilton Health Sciences, Dept. of Nuclear Medicine, Hamilton, Ontario (Canada); McMaster Univ., Dept. of Radiology, Hamilton, Ontario (Canada)]. E-mail: webber@hhsc.ca; Morrison, J. [McMaster Children' s Hospital, Hamilton, Ontario (Canada); Beaumont, L.F. [Hamilton Health Sciences, Dept. of Nuclear Medicine, Hamilton, Ontario (Canada); Barr, R.D. [McMaster Children' s Hospital, Hamilton, Ontario (Canada); McMaster Univ., Dept. of Pediatrics, Hamilton, Ontario (Canada)

    2007-02-15

    Measurements of body composition have evident value in evaluating growing children and adolescents, and dual-energy X-ray absorptiometry (DXA) is a tool that provides accurate measurements of whole-body bone mineral content (WBBMC), lean body mass (LBM), and fat mass (FM). To interpret such measurements in the context of ill health, normative values must be available. Such information could be expected to be regionally specific because of differences in ethnic, dietary, and physical activity determinants. In this study, DXA was performed with Hologic densitometers in normal girls (n = 91) and boys (n 88) between 3 and 18 years of age. The derivation of normal ranges is presented for boys and girls. The correlation of the sum of WBBMC, LBM, and FM with directly measured body weight was almost perfect (r > 0.997). As expected, FM and body mass index correlated strongly. The normal values for WBBMC, LBM, and FM from this study are compared with other Canadian data and with published normative data from Argentina and the Netherlands, all of which use different densitometers. The results of this study allow the calculation of z scores for each facet of body composition and facilitate the use of DXA to report routine evaluations of body composition in children and adolescents. (author)

  19. Whole-body bone mineral content, lean body mass, and fat mass measured by dual-energy x-ray absorptiometry in a population of normal Canadian children and adolescents

    International Nuclear Information System (INIS)

    Sala, A.; Webber, C.E.; Morrison, J.; Beaumont, L.F.; Barr, R.D.

    2007-01-01

    Measurements of body composition have evident value in evaluating growing children and adolescents, and dual-energy X-ray absorptiometry (DXA) is a tool that provides accurate measurements of whole-body bone mineral content (WBBMC), lean body mass (LBM), and fat mass (FM). To interpret such measurements in the context of ill health, normative values must be available. Such information could be expected to be regionally specific because of differences in ethnic, dietary, and physical activity determinants. In this study, DXA was performed with Hologic densitometers in normal girls (n = 91) and boys (n 88) between 3 and 18 years of age. The derivation of normal ranges is presented for boys and girls. The correlation of the sum of WBBMC, LBM, and FM with directly measured body weight was almost perfect (r > 0.997). As expected, FM and body mass index correlated strongly. The normal values for WBBMC, LBM, and FM from this study are compared with other Canadian data and with published normative data from Argentina and the Netherlands, all of which use different densitometers. The results of this study allow the calculation of z scores for each facet of body composition and facilitate the use of DXA to report routine evaluations of body composition in children and adolescents. (author)

  20. The effects of frequency-encoding gradient upon detectability of the margins and height measurements of normal adult pituitary glands

    International Nuclear Information System (INIS)

    Taketomi, A.; Sato, N.; Aoki, J.; Endo, K.

    2004-01-01

    We investigated the effects of frequency-encoding gradient (FEG) upon detectability and height measurements of the normal adult pituitary gland. We obtained two sets of T1-weighted sagittal images of the pituitary gland from 70 adult subjects without known pituitary dysfunction using 1.5 tesla imagers; one with an inferior-superior FEG, and one with an anterior-posterior FEG. We classified the subjects into three types according to the distribution of fatty marrow in the clivus. Each set of images was assessed for pituitary height on midline sagittal images, and detectability of pituitary margins. Height measurements and detectability scores were evaluated for significant difference between the two FEGs. In subjects with fatty marrow in the clivus, there was significant difference between pituitary height measurements (P<0.005) and pituitary margin detectability (P<0.001). Care should be taken to image the pituitary gland using an anterior-posterior FEG. (orig.)

  1. Measurement of normalized differential $t\\bar{t}$ cross sections in the dilepton channel from pp collisions at 13 TeV

    CERN Document Server

    Roh, Youn

    2017-01-01

    Measurements of normalized differential cross sections for top quark pair production are performed in the dilepton decay channels in proton-proton collisions at a center-of-mass energy of 13~TeV. The differential cross sections are measured with data corresponding to an integrated luminosity of 2.1~fb$^{-1}$ recorded by the CMS experiment at the LHC. We have measured the cross sections differentially as a function of the kinematic properties of the leptons (electron or muon), jets from bottom quark hadronization, top quarks, and top quark pairs at the particle and parton levels. The $t\\bar{t}$ differential cross section measurements are compared to several Monte Carlo generators that implement calculations up to next-to-leading order in perturbative quantum chromodynamics interfaced with parton showering, and also to fixed-order theoretical calculations of top quark pair production beyond next-to-leading order accuracy.

  2. Operant conditioning of the soleus H-reflex does not induce long-term changes in the gastrocnemius H-reflexes and does not disturb normal locomotion in humans.

    Science.gov (United States)

    Makihara, Yukiko; Segal, Richard L; Wolpaw, Jonathan R; Thompson, Aiko K

    2014-09-15

    In normal animals, operant conditioning of the spinal stretch reflex or the H-reflex has lesser effects on synergist muscle reflexes. In rats and people with incomplete spinal cord injury (SCI), soleus H-reflex operant conditioning can improve locomotion. We studied in normal humans the impact of soleus H-reflex down-conditioning on medial (MG) and lateral gastrocnemius (LG) H-reflexes and on locomotion. Subjects completed 6 baseline and 30 conditioning sessions. During conditioning trials, the subject was encouraged to decrease soleus H-reflex size with the aid of visual feedback. Every sixth session, MG and LG H-reflexes were measured. Locomotion was assessed before and after conditioning. In successfully conditioned subjects, the soleus H-reflex decreased 27.2%. This was the sum of within-session (task dependent) adaptation (13.2%) and across-session (long term) change (14%). The MG H-reflex decreased 14.5%, due mainly to task-dependent adaptation (13.4%). The LG H-reflex showed no task-dependent adaptation or long-term change. No consistent changes were detected across subjects in locomotor H-reflexes, EMG activity, joint angles, or step symmetry. Thus, in normal humans, soleus H-reflex down-conditioning does not induce long-term changes in MG/LG H-reflexes and does not change locomotion. In these subjects, task-dependent adaptation of the soleus H-reflex is greater than it is in people with SCI, whereas long-term change is less. This difference from results in people with SCI is consistent with the fact that long-term change is beneficial in people with SCI, since it improves locomotion. In contrast, in normal subjects, long-term change is not beneficial and may necessitate compensatory plasticity to preserve satisfactory locomotion. Copyright © 2014 the American Physiological Society.

  3. MATHEMATICAL ANALYSIS OF DENTAL ARCH OF CHILDREN IN NORMAL OCCLUSION: A LITERATURE REVIEW

    Directory of Open Access Journals (Sweden)

    M. Abu-Hussein DDS, MScD, MSc, DPD

    2012-03-01

    Full Text Available AIM. This paper is an attempt to compare and analyze the various mathematical models for defining the dental arch curvature of children in normal occlusion based upon a review of available literature. Background. While various studies have touched upon ways to cure or prevent dental diseases and upon surgical ways for teeth reconstitution to correct teeth anomalies during childhood, a substantial literature also exists, attempting to mathematically define the dental arch of children in normal occlusion. This paper reviews these dental studies and compares them analytically. Method. The paper compares the different mathematical approaches, highlights the basic assumptions behind each model, underscores the relevancy and applicability of the same, and also lists applicable mathematical formulae. Results. Each model has been found applicable to specific research conditions, as a universal mathematical model for describing the human dental arch still eludes satisfactory definition. The models necessarily need to include the features of the dental arch, such as shape, spacing between teeth and symmetry or asymmetry, but they also need substantial improvement. Conclusions. While the paper shows that the existing models are inadequate in properly defining the human dental arch, it also acknowledges that future research based on modern imaging techniques and computeraided simulation could well succeed in deriving an allinclusive definition for the human dental curve till now eluding the experts.

  4. Normal-incidence spectroscopic ellipsometry for critical dimension monitoring

    International Nuclear Information System (INIS)

    Huang, Hsu-Ting; Kong, Wei; Terry, Fred Lewis

    2001-01-01

    In this letter, we show that normal-incidence spectroscopic ellipsometry can be used for high-accuracy topography measurements on surface relief gratings. We present both experimental and theoretical results which show that spectroscopic ellipsometry or reflectance-difference spectroscopy at near-normal incidence coupled with vector diffraction theory for data analysis is capable of high-accuracy critical dimension (CD), feature height, and sidewall angle measurements in the extreme submicron regime. Quantitative comparisons of optical and cross-sectional scanning electron microscopy (SEM) topography measurements from a number of 350 nm line/space reactive-ion-etched Si gratings demonstrate the strong potential for in situ etching monitoring. This technique can be used for both ex situ and in situ applications and has the potential to replace the use of CD-SEM measurements in some applications. [copyright] 2001 American Institute of Physics

  5. Quaternion normalization in additive EKF for spacecraft attitude determination

    Science.gov (United States)

    Bar-Itzhack, I. Y.; Deutschmann, J.; Markley, F. L.

    1991-01-01

    This work introduces, examines, and compares several quaternion normalization algorithms, which are shown to be an effective stage in the application of the additive extended Kalman filter (EKF) to spacecraft attitude determination, which is based on vector measurements. Two new normalization schemes are introduced. They are compared with one another and with the known brute force normalization scheme, and their efficiency is examined. Simulated satellite data are used to demonstrate the performance of all three schemes. A fourth scheme is suggested for future research. Although the schemes were tested for spacecraft attitude determination, the conclusions are general and hold for attitude determination of any three dimensional body when based on vector measurements, and use an additive EKF for estimation, and the quaternion for specifying the attitude.

  6. Instrument development in the measurement of unsupported arm exercise endurance in normal adult subjects.

    Science.gov (United States)

    Breslin, E H; Adams, E; Lutz, A; Roy, C

    1993-06-01

    Many daily activities, from basic grooming to employment tasks, require adequate unsupported arm endurance (UAE). We developed an electromechanical device to measure UAE endurance. The purpose of this study was to standardize the instrument for two rates of arm motion, moderate and slow, in 18 normal adult subjects (FEVI = 3.7L +/- .78, FVC = 4.2L +/- .74, FEV1/FVC = 1.1 +/- .08). Exercise endurance limits, and the following metabolic, ventilatory, and sensation responses were determined at rest prior to exercise and at end-exercise limits for both rates of UAE:minute ventilation (Ve), tidal volume (VT), respiratory rate (RR), duty cycle (Ti/Ttot), oxygen uptake (VO2), carbon dioxide production (VCO2), inspiratory flow (VT/Ti), heart rate (HR), and visual analog scale measurements (VAS) of dyspnea (D), respiratory effort (RE), and arm fatigue (AF). Significance increases from baseline rest were shown at the endurance limits for both rates of UAE in: VO2, VCO2, Ve, VT, RR, VT/Ti, HR, VAS-D, VAS-RE, and VAS-AF. There were no changes in Ti/Ttot and SaO2 with UAE. Peak VO2, RR, Ve, VT/Ti, and VAS-D with moderate exercise were significantly greater than slow UAE; and there was a trend increase in peak HR for moderate as opposed to slow rate UAE. Despite these differences, the endurance time between the two rates of UAE were similar. These data provide standards against which UAE in COPD can be evaluated.

  7. Normal zone detectors for a large number of inductively coupled coils

    International Nuclear Information System (INIS)

    Owen, E.W.; Shimer, D.W.

    1983-01-01

    In order to protect a set of inductively coupled superconducting magnets, it is necessary to locate and measure normal zone voltages that are small compared with the mutual and self-induced voltages. The method described in this report uses two sets of voltage measurements to locate and measure one or more normal zones in any number of coupled coils. One set of voltages is the outputs of bridges that balance out the self-induced voltages The other set of voltages can be the voltages across the coils, although alternatives are possible. The two sets of equations form a single combined set of equations. Each normal zone location or combination of normal zones has a set of these combined equations associated with it. It is demonstrated that the normal zone can be located and the correct set chosen, allowing determination of the size of the normal zone. Only a few operations take plae in a working detector: multiplication of a constant, addition, and simple decision-making. In many cases the detector for each coil, although weakly linked to the other detectors, can be considered to be independent. An example of the detector design is given for four coils with realistic parameters. The effect on accuracy of changes in the system parameters is discussed

  8. Calorimetric measurement of strong γ emitting sources

    International Nuclear Information System (INIS)

    Brangier, B.; Herczeg, C.; Henry, R.

    1968-01-01

    This publication gives the principle and a description of an adiabatic calorimeter for measuring the real activity of strong gamma-emitting sources by absorbing the emitted energy in a mass of copper. Because of the difficulty of evaluating the amount self- absorption, we have built a calorimeter for measuring the self- absorption, and a description of it is given.The results of these three measurements are fairly satisfactory. The calibration and the actual measurements obtained are given with a few corrections made necessary by the design of the apparatus. The correlation of the various results is discussed. (author) [fr

  9. Interleaving subthalamic nucleus deep brain stimulation to avoid side effects while achieving satisfactory motor benefits in Parkinson disease

    Science.gov (United States)

    Zhang, Shizhen; Zhou, Peizhi; Jiang, Shu; Wang, Wei; Li, Peng

    2016-01-01

    Abstract Background: Deep brain stimulation (DBS) of the subthalamic nucleus is an effective treatment for advanced Parkinson disease (PD). However, achieving ideal outcomes by conventional programming can be difficult in some patients, resulting in suboptimal control of PD symptoms and stimulation-induced adverse effects. Interleaving stimulation (ILS) is a newer programming technique that can individually optimize the stimulation area, thereby improving control of PD symptoms while alleviating stimulation-induced side effects after conventional programming fails to achieve the desired results. Methods: We retrospectively reviewed PD patients who received DBS programming during the previous 4 years in our hospital. We collected clinical and demographic data from 12 patients who received ILS because of incomplete alleviation of PD symptoms or stimulation-induced adverse effects after conventional programming had proven ineffective or intolerable. Appropriate lead location was confirmed with postoperative reconstruction images. The rationale and clinical efficacy of ILS was analyzed. Results: We divided our patients into 4 groups based on the following symptoms: stimulation-induced dysarthria and choreoathetoid dyskinesias, gait disturbance, and incomplete control of parkinsonism. After treatment with ILS, patients showed satisfactory improvement in PD symptoms and alleviation of stimulation-induced side effects, with a mean improvement in Unified PD Rating Scale motor scores of 26.9%. Conclusions: ILS is a newer choice and effective programming strategy to maximize symptom control in PD while decreasing stimulation-induced adverse effects when conventional programming fails to achieve satisfactory outcome. However, we should keep in mind that most DBS patients are routinely treated with conventional stimulation and that not all patients benefit from ILS. ILS is not recommended as the first choice of programming, and it is recommended only when patients have

  10. The value of CT measurement of normal human mandible, hyoid and the airway area at the hyoid level

    International Nuclear Information System (INIS)

    Chen Changliang; Zhang Jia; Ge Pingjiang; Zhang Siyi

    2004-01-01

    Objective: To determine the normal value and clinical significance of the lengths and angles of both mandible and hyoid, and their relationship with cervical vertebra as well as the transverse area of the airway at the hyoid level using CT. Methods: Several lines and angles on the CT images were measured in 68 normal subjects. Line A was the length between both free ends of the mandible; line B was the distance from the body of the mandible to line A; Line C was the distance from line A to the anterior aspect of the cervical vertebra. α 1 was the angle between the middle of mandible body and its two free ends. Line a was the distance between two free ends of greater horn of hyoid bone. Line b was the distance from hyoid to line a. Line c was the distance from line a to the cervical vertebra. α 2 was the angle between the middle of hyoid body and its two free ends. S stood for the area of the airway at the hyoid level. SPSS 11.5 statistical analysis package was used to analyze the results. Results: The average and median distance/angle of various measurements were as follows: line A was (89.28±5.90) mm and 88.70 mm, line B was (62.61±5.78) mm and 62.50 mm, line C was (9.29±3.29) mm and 4.20 mm, α 1 was (71.25±6.77) degree and 71.05 degree, line a was (38.69 ± 6.07) mm and 39.90 mm, line b was (28.79 ± 4.37) mm and 28.50 mm, line c was (1.91 ± 3.03) mm and 1.75 mm, α 2 was (68.47 ± 15.71) degree and 66.95 degree. The average S was (436.14 ± 160.37) mm 2 and median was 431.75 mm 2 . Conclusion: It is easy to measure the three lines and the two angles of mandible and hyoid. The measurement is of vital importance in the diagnosis and treatment for obstructive sleep apnea syndrome

  11. Measurement with nasal scintigraphy of nasal mucociliary clearance in normal man

    International Nuclear Information System (INIS)

    Murai, Sumiko

    1989-01-01

    Nasal mucociliary function was evaluated by nasal scintigraphy in normal subjects. A microdrop of HSA or saline labelled with 99m Tc was dripped into the middle part of each middle meatus in the nasal cavity and its clearance was observed by scinticamera. The accumulated concentration of RI was determined every 30 seconds for 10 minutes. The changes of accumulated concentration were studied, and a curve of decreasing RI-counts was obtained, with the 'clearance rate' defined as 100% for the count at the initial 30 seconds and 'half time' as the time when radioactivity was reduced to one half the initial count. Nasal resistance was measured by rhinomanometry with the oscillation method. In nonsmokers, 10μl of saline was cleared (78.0±10.4%) significantly faster than 10μl of HSA (59.9±24.6%), and there was no significant difference in the clearance between 10μl and 5μl of HSA (55.9±27.7%). In smakers, the mucociliary clearance of 10μl of HSA and saline was significantly lower than in nonsmokers. The clearance of 10μl of HSA reflects a pathological state much better than that of 5μl. In nonsmokers, there is a significant negative correlation between nasal resistance and clearance rate, suggesting that the more patent the nose, the faster the mucociliary clearance. When both nostrils were closed, the clearance rate was significantly depressed. When one nostril was closed, there was no significant effect on clearance. Nasal resistance was decreased by exercise with a bicycle ergometer. Nasal mucociliary clearance was slightly decreased after exercise but not significantly so. (J.P.N.)

  12. Ureterocolonic anastomosis in clinically normal dogs

    International Nuclear Information System (INIS)

    Stone, E.A.; Walter, M.C.; Goldschmidt, M.H.; Biery, D.N.; Bovee, K.C.

    1988-01-01

    Ureterocolonic anastomosis was evaluated in 13 clinically normal dogs. Urinary continence was maintained after surgery, and the procedure was completed without technique errors in all but 2 dogs. Three dogs died within 5 weeks (2 of undetermined causes and 1 of aspiration pneumonia and neurologic disease), and 1 dog was euthanatized 4 months after surgery because of neurologic signs. Two healthy dogs were euthanatized 3 months after surgery for light microscopic evaluation of their kidneys. Five dogs were euthanatized 6 months after surgery for light microscopic evaluation of their kidneys. Gastrointestinal and neurologic disturbances developed in 4 dogs at various postoperative intervals. Plasma ammonia concentration measured in 2 dogs with neurologic signs was increased. Plasma ammonia concentration measured in 5 dogs without neurologic signs was within normal limits. All 5 dogs, in which metabolic acidosis was diagnosed, had high normal or above normal serum chloride concentration. Serum urea nitrogen values were increased after surgery because of colonic absorption of urea. Serum creatinine concentration was increased in 1 dog 6 months after surgery. Individual kidney glomerular filtration rate was reduced in 38% (3/8) of the kidneys from 4 other dogs at 6 months after surgery. Of 5 dogs euthanatized at 3 to 4 months after surgery, 4 had bilateral pyelitis, and 1 had unilateral pyelonephritis. Six months after surgery, pyelonephritis was diagnosed in 40% (4/10) of the kidneys from 5 dogs. The ureterocolonic anastomosis procedure is a salvage procedure that should allow complete cystectomy. However, variable degress of metabolic acidosis, hyperammonemia, and neurologic disease may result

  13. Normal stresses in semiflexible polymer hydrogels

    Science.gov (United States)

    Vahabi, M.; Vos, Bart E.; de Cagny, Henri C. G.; Bonn, Daniel; Koenderink, Gijsje H.; MacKintosh, F. C.

    2018-03-01

    Biopolymer gels such as fibrin and collagen networks are known to develop tensile axial stress when subject to torsion. This negative normal stress is opposite to the classical Poynting effect observed for most elastic solids including synthetic polymer gels, where torsion provokes a positive normal stress. As shown recently, this anomalous behavior in fibrin gels depends on the open, porous network structure of biopolymer gels, which facilitates interstitial fluid flow during shear and can be described by a phenomenological two-fluid model with viscous coupling between network and solvent. Here we extend this model and develop a microscopic model for the individual diagonal components of the stress tensor that determine the axial response of semiflexible polymer hydrogels. This microscopic model predicts that the magnitude of these stress components depends inversely on the characteristic strain for the onset of nonlinear shear stress, which we confirm experimentally by shear rheometry on fibrin gels. Moreover, our model predicts a transient behavior of the normal stress, which is in excellent agreement with the full time-dependent normal stress we measure.

  14. Is the classical two-term approximation of electron kinetic theory satisfactory for swarms and plasmas?

    International Nuclear Information System (INIS)

    White, R D; Robson, R E; Schmidt, B; Morrison, Michael A

    2003-01-01

    The 'two-term' approximation (representation of the electron distribution by the first two terms of an expansion in spherical harmonics in velocity space) continues to occupy a central role in the low-temperature plasma physics literature, in spite of the mass of evidence illustrating its inadequacy in the swarm (free diffusion) limit for many molecular gases. Part of the problem lies in the failure of many authors to specify quantitatively what they mean when they say that the two-term approximation is 'acceptable'. Thus for example, an error of 10% in transport coefficients may well be acceptable in many plasma applications, but for analysis of highly accurate swarm experiments to compare with ab initio and beam-derived cross-sections, 0.1% or less is required, making 'multi-term' analysis mandatory. While reconciliation of the swarm and plasma literature along the lines of two different accuracy regimes may thus be possible, we dispute claims that the two-term approximation is generally satisfactory for inversion of swarm experiment data to obtain electron impact cross-sections. The unsatisfactory nature of other assumptions implicit in much of the modern plasma kinetic theory literature is also discussed

  15. Normalized modes at selected points without normalization

    Science.gov (United States)

    Kausel, Eduardo

    2018-04-01

    As every textbook on linear algebra demonstrates, the eigenvectors for the general eigenvalue problem | K - λM | = 0 involving two real, symmetric, positive definite matrices K , M satisfy some well-defined orthogonality conditions. Equally well-known is the fact that those eigenvectors can be normalized so that their modal mass μ =ϕT Mϕ is unity: it suffices to divide each unscaled mode by the square root of the modal mass. Thus, the normalization is the result of an explicit calculation applied to the modes after they were obtained by some means. However, we show herein that the normalized modes are not merely convenient forms of scaling, but that they are actually intrinsic properties of the pair of matrices K , M, that is, the matrices already "know" about normalization even before the modes have been obtained. This means that we can obtain individual components of the normalized modes directly from the eigenvalue problem, and without needing to obtain either all of the modes or for that matter, any one complete mode. These results are achieved by means of the residue theorem of operational calculus, a finding that is rather remarkable inasmuch as the residues themselves do not make use of any orthogonality conditions or normalization in the first place. It appears that this obscure property connecting the general eigenvalue problem of modal analysis with the residue theorem of operational calculus may have been overlooked up until now, but which has in turn interesting theoretical implications.Á

  16. Normalized inverse characterization of sound absorbing rigid porous media.

    Science.gov (United States)

    Zieliński, Tomasz G

    2015-06-01

    This paper presents a methodology for the inverse characterization of sound absorbing rigid porous media, based on standard measurements of the surface acoustic impedance of a porous sample. The model parameters need to be normalized to have a robust identification procedure which fits the model-predicted impedance curves with the measured ones. Such a normalization provides a substitute set of dimensionless (normalized) parameters unambiguously related to the original model parameters. Moreover, two scaling frequencies are introduced, however, they are not additional parameters and for different, yet reasonable, assumptions of their values, the identification procedure should eventually lead to the same solution. The proposed identification technique uses measured and computed impedance curves for a porous sample not only in the standard configuration, that is, set to the rigid termination piston in an impedance tube, but also with air gaps of known thicknesses between the sample and the piston. Therefore, all necessary analytical formulas for sound propagation in double-layered media are provided. The methodology is illustrated by one numerical test and by two examples based on the experimental measurements of the acoustic impedance and absorption of porous ceramic samples of different thicknesses and a sample of polyurethane foam.

  17. Distinguishing hyperhidrosis and normal physiological sweat production

    DEFF Research Database (Denmark)

    Thorlacius, Linnea; Gyldenløve, Mette; Zachariae, Claus

    2015-01-01

    of this study was to establish reference intervals for normal physiological axillary and palmar sweat production. METHODS: Gravimetric testing was performed in 75 healthy control subjects. Subsequently, these results were compared with findings in a cohort of patients with hyperhidrosis and with the results...... 100 mg/5 min. CONCLUSIONS: A sweat production rate of 100 mg/5 min as measured by gravimetric testing may be a reasonable cut-off value for distinguishing axillary and palmar hyperhidrosis from normal physiological sweat production....

  18. Spectrometric kidney depth measurement method

    International Nuclear Information System (INIS)

    George, P.; Soussaline, F.; Raynaud, C.

    1976-01-01

    The method proposed uses the single posterior surface measurement of the kidney radioactivity distribution. The ratio C/P of the number of scattered photons to the number of primary photons, which is a function of the tissue depth penetrated, is calculated for a given region. The parameters on which the C/P value depends are determined from studies on phantoms. On the basis of these results the kidney depth was measured on a series of 13 patients and a correlation was established between the value thus calculated and that obtained by the profile method. The reproducibility of the method is satisfactory [fr

  19. Quantifying normal ankle joint volume: An anatomic study

    Directory of Open Access Journals (Sweden)

    Draeger Reid

    2009-01-01

    Full Text Available Background: Many therapeutic and diagnostic modalities such as intraarticular injections, arthrography and ankle arthroscopy require introduction of fluid into the ankle joint. Little data are currently available in the literature regarding the maximal volume of normal, nonpathologic, human ankle joints. The purpose of this study was to measure the volume of normal human ankle joints. Materials and Methods: A fluoroscopic guided needle was passed into nine cadaveric adult ankle joints. The needle was connected to an intracompartmental pressure measurement device. A radiopaque dye was introduced into the joint in 2 mL boluses, while pressure measurements were recorded. Fluid was injected into the joint until three consecutive pressure measurements were similar, signifying a maximal joint volume. Results: The mean maximum ankle joint volume was 20.9 ± 4.9 mL (range, 16-30 mL. The mean ankle joint pressure at maximum volume was 142.2 ± 13.8 mm Hg (range, 122-166 mm Hg. Two of the nine samples showed evidence of fluid tracking into the synovial sheath of the flexor hallucis longus tendon. Conclusion: Maximal normal ankle joint volume was found to vary between 16-30 mL. This study ascertains the communication between the ankle joint and the flexor hallucis longus tendon sheath. Exceeding maximal ankle joint volume suggested by this study during therapeutic injections, arthrography, or arthroscopy could potentially damage the joint.

  20. Clarifying Normalization

    Science.gov (United States)

    Carpenter, Donald A.

    2008-01-01

    Confusion exists among database textbooks as to the goal of normalization as well as to which normal form a designer should aspire. This article discusses such discrepancies with the intention of simplifying normalization for both teacher and student. This author's industry and classroom experiences indicate such simplification yields quicker…

  1. Feasibility of temporary protective embolization of normal liver tissue using degradable starch microspheres during radioembolization of liver tumours

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Carsten [University of Bonn, Department of Radiology, Bonn (Germany); Pieper, Claus Christian; Wilhelm, Kai E.; Schild, Hans Heinz [University of Bonn, Department of Radiology, Bonn (Germany); Ezziddin, Samer; Ahmadzadehfar, Hojjat [University of Bonn, Department of Nuclear Medicine, Bonn (Germany)

    2014-02-15

    To describe a new approach to protect nontarget healthy liver tissue using degradable starch microspheres (DSM) as a short-term embolizate during radioembolization of liver tumours with {sup 90}Y microspheres. Between December 2011 and July 2012 radioembolization was performed in 54 patients. Five of these patients (three women, two men; mean age 67 years) underwent protective temporary embolization using DSM (EmboCept {sup registered} S) of normal liver tissue that could not be excluded from the area treated by radioembolization through catheter repositioning. Clinical symptoms, laboratory findings, preinterventional imaging, and {sup 99m}Tc-MAA and bremsstrahlung SPECT/CT, as well as baseline and follow-up imaging with {sup 18}F-FDG PET/CT and MRI, were evaluated in relation to the technical and clinical success of the protective embolization. Temporary embolization of arteries supplying normal liver tissue using DSM was technically successful in all five patients. {sup 99m}Tc-MAA SPECT/CT performed in the first two patients after DSM injection showed no increased pulmonary shunting compared to the MAA test injection without DSM. Bremsstrahlung SPECT/CT after radioembolization demonstrated satisfactory irradiation of the tumour and successful protection of normal liver tissue. There were only mild hepatotoxic effects (grade 1) on laboratory follow-up examinations, and no adverse events associated with DSM embolization or radioembolization were recorded. Temporary embolization with DSM before radioembolization is feasible and can effectively protect areas of normal liver tissue from irradiation and avoid permanent embolization if other methods such as catheter repositioning are not possible due to the location of the metastases. (orig.)

  2. Feasibility of temporary protective embolization of normal liver tissue using degradable starch microspheres during radioembolization of liver tumours

    International Nuclear Information System (INIS)

    Meyer, Carsten; Pieper, Claus Christian; Wilhelm, Kai E.; Schild, Hans Heinz; Ezziddin, Samer; Ahmadzadehfar, Hojjat

    2014-01-01

    To describe a new approach to protect nontarget healthy liver tissue using degradable starch microspheres (DSM) as a short-term embolizate during radioembolization of liver tumours with 90 Y microspheres. Between December 2011 and July 2012 radioembolization was performed in 54 patients. Five of these patients (three women, two men; mean age 67 years) underwent protective temporary embolization using DSM (EmboCept registered S) of normal liver tissue that could not be excluded from the area treated by radioembolization through catheter repositioning. Clinical symptoms, laboratory findings, preinterventional imaging, and 99m Tc-MAA and bremsstrahlung SPECT/CT, as well as baseline and follow-up imaging with 18 F-FDG PET/CT and MRI, were evaluated in relation to the technical and clinical success of the protective embolization. Temporary embolization of arteries supplying normal liver tissue using DSM was technically successful in all five patients. 99m Tc-MAA SPECT/CT performed in the first two patients after DSM injection showed no increased pulmonary shunting compared to the MAA test injection without DSM. Bremsstrahlung SPECT/CT after radioembolization demonstrated satisfactory irradiation of the tumour and successful protection of normal liver tissue. There were only mild hepatotoxic effects (grade 1) on laboratory follow-up examinations, and no adverse events associated with DSM embolization or radioembolization were recorded. Temporary embolization with DSM before radioembolization is feasible and can effectively protect areas of normal liver tissue from irradiation and avoid permanent embolization if other methods such as catheter repositioning are not possible due to the location of the metastases. (orig.)

  3. Anthropometric indices are not satisfactory predictors of metabolic comorbidities in obese children and adolescents.

    Science.gov (United States)

    Morandi, Anita; Miraglia Del Giudice, Emanuele; Martino, Francesco; Martino, Eliana; Bozzola, Mauro; Maffeis, Claudio

    2014-12-01

    To assess the accuracy of body mass index (BMI), Z score of the BMI, waist circumference, and waist-to-height ratio in selecting obese children with fasting metabolic impairments or impaired glucose tolerance. In a cohort of 883 obese children and adolescents (age 8-18 years), we assessed the associations of anthropometric indices with traditional metabolic complications of obesity (impaired fasting glucose, impaired glucose tolerance, hypertension, high triglycerides, low high-density lipoprotein-cholesterol). The accuracy of anthropometric indices as markers of metabolic impairment was assessed by receiver operating characteristic analysis and the areas under the receiver operating characteristics curves (AUROCs) of anthropometric indices were compared with each other by the DeLong test. BMI, Z score of the BMI, waist circumference, and waist-to-height ratio were associated with metabolic impairments but showed low to moderate accuracy in discriminating both single and clustered metabolic impairments. The AUROCs ranged from 0.55-0.70. The 4 anthropometric indices did not show significantly different AUROCs as predictors of clustered metabolic risk factors (all P values of DeLong tests: >.05). Commonly used anthropometric indices are not satisfactory markers of metabolic comorbidity among obese children and adolescents and should not be adopted as screening tools for the metabolic assessment of this category of patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Measurement of the cross-sectional area of the dural tube in the lumbar spine on magnetic resonance imaging. Comparison between normal, pre- and post-discectomy conditions

    International Nuclear Information System (INIS)

    Matsubayashi, Yasutomo

    1997-01-01

    This study evaluated the usefulness of pre- and postoperative magnetic resonance imaging (MRI) of lumbar disc hernia with special attention to measurement of the cross-sectional area of the dural tube. Twenty-five patients (20 men and 5 women; 25 discs) who underwent posterior lumbar discectomy and 73 normal individuals (44 men and 29 women; 219 discs) of a similar age distribution were studied. Axial MRI was mainly used for the measurement of the dural tube. In the patient group, MRI examination was performed 1, 3, 6, and 12 months postoperatively. Assessment of the clinical symptoms was also included and used for comparison with the MRI evaluation. The cross-sectional area was significantly reduced to about 50% of the normal preoperatively. One month postoperatively, there was no significant increase in the size of the area, but after three months, the area increased significantly and progressed to the normal size within a year. One-month postoperatively, MRI examination was not considered useful because of postoperative hematoma and/or edema at the surgical site. The increase in the size of the cross-sectional area of the dural tube correlated well with the improvement in clinical symptoms. Three-months postoperatively, MRI evaluation of the lumbar disc seemed useful and measurement of the cross-sectional area of the dural tube appeared to serve as an indicator of the effectiveness of the surgery. (author)

  5. Measurement of the cross-sectional area of the dural tube in the lumbar spine on magnetic resonance imaging. Comparison between normal, pre- and post-discectomy conditions

    Energy Technology Data Exchange (ETDEWEB)

    Matsubayashi, Yasutomo [Juntendo Univ., Tokyo (Japan). School of Medicine

    1997-07-01

    This study evaluated the usefulness of pre- and postoperative magnetic resonance imaging (MRI) of lumbar disc hernia with special attention to measurement of the cross-sectional area of the dural tube. Twenty-five patients (20 men and 5 women; 25 discs) who underwent posterior lumbar discectomy and 73 normal individuals (44 men and 29 women; 219 discs) of a similar age distribution were studied. Axial MRI was mainly used for the measurement of the dural tube. In the patient group, MRI examination was performed 1, 3, 6, and 12 months postoperatively. Assessment of the clinical symptoms was also included and used for comparison with the MRI evaluation. The cross-sectional area was significantly reduced to about 50% of the normal preoperatively. One month postoperatively, there was no significant increase in the size of the area, but after three months, the area increased significantly and progressed to the normal size within a year. One-month postoperatively, MRI examination was not considered useful because of postoperative hematoma and/or edema at the surgical site. The increase in the size of the cross-sectional area of the dural tube correlated well with the improvement in clinical symptoms. Three-months postoperatively, MRI evaluation of the lumbar disc seemed useful and measurement of the cross-sectional area of the dural tube appeared to serve as an indicator of the effectiveness of the surgery. (author)

  6. Self-normalizing multiple-echo technique for measuring the in vivo apparent diffusion coefficient

    International Nuclear Information System (INIS)

    Perman, W.H.; Gado, M.; Sandstrom, J.C.

    1989-01-01

    This paper presents work to develop a new technique for quantitating the in vivo apparent diffusion/perfusion coefficient (ADC) by obtaining multiple data points from only two images with the capability to normalize the data from consecutive images, thus minimizing the effect of interimage variation. Two multiple-echo (six-to eight-echo) cardiac-gated images are obtained, one without and one with additional diffusion/perfusion encoding gradients placed about the 180 RF pulses of all but the first echo. Since the first echoes of both images have identical pulse sequence parameters, variations in signal intensity-between the first echoes represent image-to-image variation. The signal intensities of the subsequent echoes with additional diffusion/perfusion encoding gradients are then normalized by using the ratio of the first-echo signal intensities

  7. Measurement of liver volume by emission computed tomography

    International Nuclear Information System (INIS)

    Kan, M.K.; Hopkins, G.B.

    1979-01-01

    In 22 volunteers without clinical or laboratory evidence of liver disease, liver volume was determined using single-photon emission computed tomography (ECT). This technique provided excellent object contrast between the liver and its surroundings and permitted calculation of liver volume without geometric assumptions about the liver's configuration. Reproducibility of results was satisfactory, with a root-mean-square error of less than 6% between duplicate measurements in 15 individuals. The volume measurements were validated by the use of phantoms

  8. Compressed normalized block difference for object tracking

    Science.gov (United States)

    Gao, Yun; Zhang, Dengzhuo; Cai, Donglan; Zhou, Hao; Lan, Ge

    2018-04-01

    Feature extraction is very important for robust and real-time tracking. Compressive sensing provided a technical support for real-time feature extraction. However, all existing compressive tracking were based on compressed Haar-like feature, and how to compress many more excellent high-dimensional features is worth researching. In this paper, a novel compressed normalized block difference feature (CNBD) was proposed. For resisting noise effectively in a highdimensional normalized pixel difference feature (NPD), a normalized block difference feature extends two pixels in the original formula of NPD to two blocks. A CNBD feature can be obtained by compressing a normalized block difference feature based on compressive sensing theory, with the sparse random Gaussian matrix as the measurement matrix. The comparative experiments of 7 trackers on 20 challenging sequences showed that the tracker based on CNBD feature can perform better than other trackers, especially than FCT tracker based on compressed Haar-like feature, in terms of AUC, SR and Precision.

  9. Correlated random sampling for multivariate normal and log-normal distributions

    International Nuclear Information System (INIS)

    Žerovnik, Gašper; Trkov, Andrej; Kodeli, Ivan A.

    2012-01-01

    A method for correlated random sampling is presented. Representative samples for multivariate normal or log-normal distribution can be produced. Furthermore, any combination of normally and log-normally distributed correlated variables may be sampled to any requested accuracy. Possible applications of the method include sampling of resonance parameters which are used for reactor calculations.

  10. Measurements of Development in L2 Written Production: The Case of L2 Chinese

    Science.gov (United States)

    Jiang, Wenying

    2013-01-01

    This study investigates measures for second language (L2) writing development. A T-unit, which has been found the most satisfactory unit of analysis for measuring L2 development in English, is extended to measure L2 Chinese writing development through a cross-sectional design in this study. Data were collected from three L2 Chinese learner groups…

  11. Dependency of cardiac rubidium-82 imaging quantitative measures on age, gender, vascular territory, and software in a cardiovascular normal population.

    Science.gov (United States)

    Sunderland, John J; Pan, Xiao-Bo; Declerck, Jerome; Menda, Yusuf

    2015-02-01

    Recent technological improvements to PET imaging equipment combined with the availability of software optimized to calculate regional myocardial blood flow (MBF) and myocardial flow reserve (MFR) create a paradigm shifting opportunity to provide new clinically relevant quantitative information to cardiologists. However, clinical interpretation of the MBF and MFR is entirely dependent upon knowledge of MBF and MFR values in normal populations and subpopulations. This work reports Rb-82-based MBF and MFR measurements for a series of 49 verified cardiovascularly normal subjects as a preliminary baseline for future clinical studies. Forty-nine subjects (24F/25M, ages 41-69) with low probability for coronary artery disease and with normal exercise stress test were included. These subjects underwent rest/dipyridamole stress Rb-82 myocardial perfusion imaging using standard clinical techniques (40 mCi injection, 6-minute acquisition) using a Siemens Biograph 40 PET/CT scanner with high count rate detector option. List mode data was rehistogrammed into 26 dynamic frames (12 × 5 seconds, 6 × 10 seconds, 4 × 20 seconds, 4 × 40 seconds). Cardiac images were processed, and MBF and MFR calculated using Siemens syngo MBF, PMOD, and FlowQuant software using a single compartment Rb-82 model. Global myocardial blood flow under pharmacological stress for the 24 females as measured by PMOD, syngo MBF, and FlowQuant were 3.10 ± 0.72, 2.80 ± 0.66, and 2.60 ± 0.63 mL·minute(-1)·g(-1), and for the 25 males was 2.60 ± 0.84, 2.33 ± 0.75, 2.15 ± 0.62 mL·minute(-1)·g(-1), respectively. Rest flows for PMOD, syngo MBF, and FlowQuant averaged 1.32 ± 0.42, 1.20 ± 0.33, and 1.06 ± 0.38 mL·minute(-1)·g(-1) for the female subjects, and 1.12 ± 0.29, 0.90 ± 0.26, and 0.85 ± 0.24 mL·minute(-1)·g(-1) for the males. Myocardial flow reserves for PMOD, syngo MBF, and FlowQuant for the female normals were calculated to be 2.50 ± 0.80, 2.53 ± 0.67, 2.71 ± 0.90, and 2.50 ± 1.19, 2

  12. Cross Correlation versus Normalized Mutual Information on Image Registration

    Science.gov (United States)

    Tan, Bin; Tilton, James C.; Lin, Guoqing

    2016-01-01

    This is the first study to quantitatively assess and compare cross correlation and normalized mutual information methods used to register images in subpixel scale. The study shows that the normalized mutual information method is less sensitive to unaligned edges due to the spectral response differences than is cross correlation. This characteristic makes the normalized image resolution a better candidate for band to band registration. Improved band-to-band registration in the data from satellite-borne instruments will result in improved retrievals of key science measurements such as cloud properties, vegetation, snow and fire.

  13. Quantitative Measurements of Electronically Excited CH Concentration in Normal Gravity and Microgravity Coflow Laminar Diffusion Flames

    Science.gov (United States)

    Giassi, D.; Cao, S.; Stocker, D. P.; Takahashi, F.; Bennett, B. A. V.; Smooke, M. D.; Long, M. B.

    2015-01-01

    With the conclusion of the SLICE campaign aboard the ISS in 2012, a large amount of data was made available for the analysis of the effect of microgravity on laminar coflow diffusion flames. Previous work focused on the study of sooty flames in microgravity as well as the ability of numerical models to predict its formation in a simplified buoyancy-free environment. The current work shifts the investigation to soot-free flames, putting an emphasis on the chemiluminescence emission from electronically excited CH (CH*). This radical species is of significant interest in combustion studies: it has been shown that the electronically excited CH spatial distribution is indicative of the flame front position and, given the relatively simple diagnostic involved with its measurement, several works have been done trying to understand the ability of electronically excited CH chemiluminescence to predict the total and local flame heat release rate. In this work, a subset of the SLICE nitrogen-diluted methane flames has been considered, and the effect of fuel and coflow velocity on electronically excited CH concentration is discussed and compared with both normal gravity results and numerical simulations. Experimentally, the spectral characterization of the DSLR color camera used to acquire the flame images allowed the signal collected by the blue channel to be considered representative of the electronically excited CH emission centered around 431 nm. Due to the axisymmetric flame structure, an Abel deconvolution of the line-of-sight chemiluminescence was used to obtain the radial intensity profile and, thanks to an absolute light intensity calibration, a quantification of the electronically excited CH concentration was possible. Results show that, in microgravity, the maximum flame electronically excited CH concentration increases with the coflow velocity, but it is weakly dependent on the fuel velocity; normal gravity flames, if not lifted, tend to follow the same trend

  14. Assessing a Norwegian translation of the Organizational Climate Measure.

    Science.gov (United States)

    Bernstrøm, Vilde Hoff; Lone, Jon Anders; Bjørkli, Cato A; Ulleberg, Pål; Hoff, Thomas

    2013-04-01

    This study investigated the Norwegian translation of the Organizational Climate Measure developed by Patterson and colleagues. The Organizational Climate Measure is a global measure of organizational climate based on Quinn and Rohrbaugh's competing values model. The survey was administered to a Norwegian branch of an international service sector company (N = 555). The results revealed satisfactory internal reliability and interrater agreement for the 17 scales, and confirmatory factor analysis supported the original factor structure. The findings gave preliminary support for the Organizational Climate Measure as a reliable measure with a stable factor structure, and indicated that it is potentially useful in the Norwegian context.

  15. Annual rainfall statistics for stations in the Top End of Australia: normal and log-normal distribution analysis

    International Nuclear Information System (INIS)

    Vardavas, I.M.

    1992-01-01

    A simple procedure is presented for the statistical analysis of measurement data where the primary concern is the determination of the value corresponding to a specified average exceedance probability. The analysis employs the normal and log-normal frequency distributions together with a χ 2 -test and an error analysis. The error analysis introduces the concept of a counting error criterion, or ζ-test, to test whether the data are sufficient to make the Z 2 -test reliable. The procedure is applied to the analysis of annual rainfall data recorded at stations in the tropical Top End of Australia where the Ranger uranium deposit is situated. 9 refs., 12 tabs., 9 figs

  16. Normalization of multidirectional red and NIR reflectances with the SAVI

    Science.gov (United States)

    Huete, A. R.; Hua, G.; Qi, J.; Chehbouni, A.; Van Leeuwen, W. J. D.

    1992-01-01

    Directional reflectance measurements were made over a semi-desert gramma grassland at various times of the growing season. View angle measurements from +40 to -40 degrees were made at various solar zenith angles and soil moisture conditions. The sensitivity of the Normalized Difference Vegetation Index (NDVI) and the Soil Adjusted Vegetation Index (SAVI) to bidirectional measurements was assessed for purposes of improving remote temporal monitoring of vegetation dynamics. The SAVI view angle response was found to be symmetric about nadir while the NDVI response was strongly anisotropic. This enabled the view angle behavior of the SAVI to be normalized with a cosine function. In contrast to the NDVI, the SAVI was able to minimize soil moisture and shadow influences for all measurement conditions.

  17. Measurement of normalized differential t-tbar cross sections in the dilepton channel from pp collisions at sqrt(s) = 13 TeV

    Energy Technology Data Exchange (ETDEWEB)

    Sirunyan, Albert M; et al.

    2017-08-25

    Normalized differential cross sections for top quark pair production are measured in the dilepton (e-e, mu-mu, and mu-e) decay channels in proton-proton collisions at a center-of-mass energy of 13 TeV. The measurements are performed with data corresponding to an integrated luminosity of 2.1 inverse-femtobarns using the CMS detector at the LHC. The cross sections are measured differentially as a function of the kinematic properties of the leptons, jets from bottom quark hadronization, top quarks, and top quark pairs at the particle and parton levels. The results are compared to several Monte Carlo generators that implement calculations up to next-to-leading order in perturbative quantum chromodynamics interfaced with parton showering, and also to fixed-order theoretical calculations of top quark pair production up to next-to-next-to-leading order.

  18. Estimating solar radiation using NOAA/AVHRR and ground measurement data

    Science.gov (United States)

    Fallahi, Somayeh; Amanollahi, Jamil; Tzanis, Chris G.; Ramli, Mohammad Firuz

    2018-01-01

    Solar radiation (SR) data are commonly used in different areas of renewable energy research. Researchers are often compelled to predict SR at ground stations for areas with no proper equipment. The objective of this study was to test the accuracy of the artificial neural network (ANN) and multiple linear regression (MLR) models for estimating monthly average SR over Kurdistan Province, Iran. Input data of the models were two data series with similar longitude, latitude, altitude, and month (number of months) data, but there were differences between the monthly mean temperatures in the first data series obtained from AVHRR sensor of NOAA satellite (DS1) and in the second data series measured at ground stations (DS2). In order to retrieve land surface temperature (LST) from AVHRR sensor, emissivity of the area was considered and for that purpose normalized vegetation difference index (NDVI) calculated from channels 1 and 2 of AVHRR sensor was utilized. The acquired results showed that the ANN model with DS1 data input with R2 = 0.96, RMSE = 1.04, MAE = 1.1 in the training phase and R2 = 0.96, RMSE = 1.06, MAE = 1.15 in the testing phase achieved more satisfactory performance compared with MLR model. It can be concluded that ANN model with remote sensing data has the potential to predict SR in locations with no ground measurement stations.

  19. Normal zone detectors for a large number of inductively coupled coils. Revision 1

    International Nuclear Information System (INIS)

    Owen, E.W.; Shimer, D.W.

    1983-01-01

    In order to protect a set of inductively coupled superconducting magnets, it is necessary to locate and measure normal zone voltages that are small compared with the mutual and self-induced voltages. The method described in this paper uses two sets of voltage measurements to locate and measure one or more normal zones in any number of coupled coils. One set of voltages is the outputs of bridges that balance out the self-induced voltages. The other set of voltages can be the voltages across the coils, although alternatives are possible. The two sets of equations form a single combined set of equations. Each normal zone location or combination of normal zones has a set of these combined equations associated with it. It is demonstrated that the normal zone can be located and the correct set chosen, allowing determination of the size of the normal zone. Only a few operations take place in a working detector: multiplication of a constant, addition, and simple decision-making. In many cases the detector for each coil, although weakly linked to the other detectors, can be considered to be independent. The effect on accuracy of changes in the system parameters is discussed

  20. Radiologic study of patellofemoral congruence in normal adults

    International Nuclear Information System (INIS)

    Diedrichs, L.C.

    1986-01-01

    In order to establish the normal position of the patella, in relation to the intercondilar sulcus, we have evaluated 72 adults patients, making use of the FICAT view in axial radiographys at 30 0 : a simple and accurate technique adopted to measure the congrunce angle in the detection of sub-luxation of the patella. The value of +9 0 was used as the normal pattern for the maximal lateral position of the patella in the intercondilar sulcus. (Author) [pt

  1. GC-Content Normalization for RNA-Seq Data

    Science.gov (United States)

    2011-01-01

    Background Transcriptome sequencing (RNA-Seq) has become the assay of choice for high-throughput studies of gene expression. However, as is the case with microarrays, major technology-related artifacts and biases affect the resulting expression measures. Normalization is therefore essential to ensure accurate inference of expression levels and subsequent analyses thereof. Results We focus on biases related to GC-content and demonstrate the existence of strong sample-specific GC-content effects on RNA-Seq read counts, which can substantially bias differential expression analysis. We propose three simple within-lane gene-level GC-content normalization approaches and assess their performance on two different RNA-Seq datasets, involving different species and experimental designs. Our methods are compared to state-of-the-art normalization procedures in terms of bias and mean squared error for expression fold-change estimation and in terms of Type I error and p-value distributions for tests of differential expression. The exploratory data analysis and normalization methods proposed in this article are implemented in the open-source Bioconductor R package EDASeq. Conclusions Our within-lane normalization procedures, followed by between-lane normalization, reduce GC-content bias and lead to more accurate estimates of expression fold-changes and tests of differential expression. Such results are crucial for the biological interpretation of RNA-Seq experiments, where downstream analyses can be sensitive to the supplied lists of genes. PMID:22177264

  2. A compact fiber optics-based heterodyne combined normal and transverse displacement interferometer.

    Science.gov (United States)

    Zuanetti, Bryan; Wang, Tianxue; Prakash, Vikas

    2017-03-01

    While Photonic Doppler Velocimetry (PDV) has become a common diagnostic tool for the measurement of normal component of particle motion in shock wave experiments, this technique has not yet been modified for the measurement of combined normal and transverse motion, as needed in oblique plate impact experiments. In this paper, we discuss the design and implementation of a compact fiber-optics-based heterodyne combined normal and transverse displacement interferometer. Like the standard PDV, this diagnostic tool is assembled using commercially available telecommunications hardware and uses a 1550 nm wavelength 2 W fiber-coupled laser, an optical focuser, and single mode fibers to transport light to and from the target. Two additional optical probes capture first-order beams diffracted from a reflective grating at the target free-surface and deliver the beams past circulators and a coupler where the signal is combined to form a beat frequency. The combined signal is then digitized and analyzed to determine the transverse component of the particle motion. The maximum normal velocity that can be measured by this system is limited by the equivalent transmission bandwidth (3.795 GHz) of the combined detector, amplifier, and digitizer and is estimated to be ∼2.9 km/s. Sample symmetric oblique plate-impact experiments are performed to demonstrate the capability of this diagnostic tool in the measurement of the combined normal and transverse displacement particle motion.

  3. Effect of Coarse Aggregate and Slag Type on the Mechanical Behavior of High and Normal Weight Concrete Used at Barrage Structure

    Directory of Open Access Journals (Sweden)

    Muhammad Sanaullah

    2017-04-01

    Full Text Available Present study is an effort to assess the composite effect of limestone aggregate and blast furnace slag on the mechanical characteristics of normal and high weight concrete at various structural units (barrage girders, main weir and block apron of New Khanki Barrage Project, Punjab. Mix designs for different concrete classes falling under the domain of high and normal weight concrete were prepared after aggregate quality testing. On attaining satisfactory results of quality testing nine concrete mixes were designed (three for each class: A1, A and B by absolute volume method (ACI- 211.1. The required compressive strength of normal and high strength was set at 6200, 5200 and 4200 Psi for the concrete types A1, A and B respectively after 28 days (ACI -318. For compressive strength assessment, a total 27 concrete cylinders were casted (9-cylinders for each mix and were water cured. The achieved average UCS of cylinder concrete specimens at 3, 7 and 28 days are 5170, 6338 and 7320 Psi for A1 – type, 3210, 4187 and 5602 Psi for A-type and 2650, 3360 and 4408 Psi for B- type mix. It has been found that all concrete mixes for suggested classes attained target strength at age of 7-days. The coarse aggregate (Margala Hill limestone and fine aggregates (from Lawrancepur /Qibla Bandi quarries used in all concrete mix designs have demonstrated a sound mechanical suitability for high and normal weight concrete.

  4. Measurement and Analysis of Normal Zone Propagation in a ReBCO Coated at Temperatures Below 50 K (Proc. 25th ICEC & ICMC2014 conference)

    NARCIS (Netherlands)

    van Nugteren, J.; Dhalle, Marc M.J.; Wessel, Wilhelm A.J.; Krooshoop, Hendrikus J.G.; Nijhuis, Arend; ten Kate, Herman H.J.

    2015-01-01

    Measurements of the quasi-adiabatic normal zone propagation velocity and quench energies of a Superpower SCS4050 copper stabilised ReBCO superconducting tape are presented over a temperature range of 23 − 47 K; in parallel applied magnetic fields of 6, 10 and 14 T; and over a current range from 50%

  5. Impedance metrology with Josephson voltage normals; Impedanzmetrologie mit Josephson-Spannungsnormalen

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Stephan; Palafox, Luis [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany). Arbeitsgruppe 2.63 ' ' Josephson-Effekt, Spannung' '

    2016-09-15

    This article first explains the fundamental principle of an impedance measurement bridge on the base of Josephson voltage normals, before both types of measurement bridges realized in the PTB are more precisely discussed.

  6. Measuring of the cerebellar volume of normal Koreans in their 20s and 40s using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Chung, Soon Cheol; Choi, Do Young; Lee, Beob Yi; Lee, Bong Soo; Eom, Jin Sup; Sohn, Jin Hun

    2004-01-01

    This study purposed to measure the standard volume of the cerebellum of normal Koreans who were in their 20s and 40s, and we also wished to find out the difference in the volume of the cerebellum according to gender and age. This study collected MR brain images from 118 people in their 20s (males: 58, females: 60) and 100 people in their 40s (males: 41, females: 59), for a total of 218 people. For each of sagittal, coronal and axial sections, the cerebellar part of the images was segmented using automatic and manual methods, and the volume was then measured. In order to observe differences according to gender and age and also to observe the interactive effect between gender and age, a two-way ANOVA test was performed using gender (2 levels) and age (2 levels) as independent variables. The average volume of the cerebellum of Koreans in their 20s was 133.74 (cm 3 ) and that of Koreans in their 40s was 121.83 (cm 3 ). The average volume of the cerebellum of male Koreans in their 20s and 40s was 134.55 (cm 3 ) and that of female Koreans was 123.06 (cm 3 ). The volume of the cerebellum was significantly larger in Koreans in their 20s than those volumes of the cerebellum of Koreans in their 40s, and the cerebellum volumes in male Koreans were larger than those of the Korean females. Moreover, the reduction of the volume of the cerebellum with age was significantly larger in male Koreans than in the Korean females. According to the results of measuring the volume of the cerebellum for normal Koreans in their 20s and 40s, the volume was significantly different according to gender and age, and the reduction of the volume of the cerebellum with age was significantly larger in men than in women

  7. Measuring of the cerebellar volume of normal Koreans in their 20s and 40s using magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soon Cheol; Choi, Do Young; Lee, Beob Yi; Lee, Bong Soo [College of Medicine, Konkuk Univ., Chungju (Korea, Republic of); Eom, Jin Sup [Chungbuk National Univ., Chungju (Korea, Republic of); Sohn, Jin Hun [Chungnam National Univ., Daejeon (Korea, Republic of)

    2004-11-01

    This study purposed to measure the standard volume of the cerebellum of normal Koreans who were in their 20s and 40s, and we also wished to find out the difference in the volume of the cerebellum according to gender and age. This study collected MR brain images from 118 people in their 20s (males: 58, females: 60) and 100 people in their 40s (males: 41, females: 59), for a total of 218 people. For each of sagittal, coronal and axial sections, the cerebellar part of the images was segmented using automatic and manual methods, and the volume was then measured. In order to observe differences according to gender and age and also to observe the interactive effect between gender and age, a two-way ANOVA test was performed using gender (2 levels) and age (2 levels) as independent variables. The average volume of the cerebellum of Koreans in their 20s was 133.74 (cm{sup 3}) and that of Koreans in their 40s was 121.83 (cm{sup 3}). The average volume of the cerebellum of male Koreans in their 20s and 40s was 134.55 (cm{sup 3}) and that of female Koreans was 123.06 (cm{sup 3}). The volume of the cerebellum was significantly larger in Koreans in their 20s than those volumes of the cerebellum of Koreans in their 40s, and the cerebellum volumes in male Koreans were larger than those of the Korean females. Moreover, the reduction of the volume of the cerebellum with age was significantly larger in male Koreans than in the Korean females. According to the results of measuring the volume of the cerebellum for normal Koreans in their 20s and 40s, the volume was significantly different according to gender and age, and the reduction of the volume of the cerebellum with age was significantly larger in men than in women.

  8. Measurement of left ventricular ejection fraction in pediatric patients using the nuclear stethoscope

    International Nuclear Information System (INIS)

    Spicer, R.L.; Rabinovitch, M.; Rosenthal, A.; Pitt, B.

    1984-01-01

    Left ventricular (LV) ejection fraction (EF) was measured in 25 patients, aged 2 weeks to 20 years (mean 8.6 years), using a portable nonimaging scintillation stethoscope. Technically satisfactory studies were obtained in 23 patients. LVEF was validated by cineangiography in 19 patients and by standard gated blood pool scintigraphy in 4. EF measured by the nuclear stethoscope correlated well with values obtained by cineangiography or scintigraphy over a wide range of EF values (18 to 79%). In children younger than 5 years (n . 11), the correlation was less satisfactory than in those older than 5 years. Although modifications in the instrument and further clinical trials with the stethoscope are needed before the device becomes clinically useful to pediatric cardiologists, our data indicate that the nuclear stethoscope can provide reliable assessment of LVEF in pediatric patients

  9. Testing Mean Differences among Groups: Multivariate and Repeated Measures Analysis with Minimal Assumptions.

    Science.gov (United States)

    Bathke, Arne C; Friedrich, Sarah; Pauly, Markus; Konietschke, Frank; Staffen, Wolfgang; Strobl, Nicolas; Höller, Yvonne

    2018-03-22

    To date, there is a lack of satisfactory inferential techniques for the analysis of multivariate data in factorial designs, when only minimal assumptions on the data can be made. Presently available methods are limited to very particular study designs or assume either multivariate normality or equal covariance matrices across groups, or they do not allow for an assessment of the interaction effects across within-subjects and between-subjects variables. We propose and methodologically validate a parametric bootstrap approach that does not suffer from any of the above limitations, and thus provides a rather general and comprehensive methodological route to inference for multivariate and repeated measures data. As an example application, we consider data from two different Alzheimer's disease (AD) examination modalities that may be used for precise and early diagnosis, namely, single-photon emission computed tomography (SPECT) and electroencephalogram (EEG). These data violate the assumptions of classical multivariate methods, and indeed classical methods would not have yielded the same conclusions with regards to some of the factors involved.

  10. Normal hepatic and splenic size in children: Scintigraphic determination

    International Nuclear Information System (INIS)

    Markisz, J.A.; New York Hospital - Cornell Medical Center, NY; Treves, S.T.; Davis, T.

    1987-01-01

    Measurements were made on sulfur colloid scintigrams of normal pediatric livers and spleens by analyzing 131 scans from 116 patients referred for liver or spleen trauma. Studies were used only if scans were normal, there was no history of malignancy or hepatic or splenic disease either prior to of after the study. Linear correlation was made with age, weight and both age and weight. All measured parameters correlated better with weight than with age, with vertical liver dimension exhibiting the best correlation (r=0.848). Multivariate analysis demonstrated uniformly better correlation of all measurements with both age and weight. Spleen and liver volumes were calculated assuming simple geometry, and showed excellent correlations. Graphical presentation of data will be useful in the clinical determination of hepatomegaly or splenomegaly in routine scintigraphy. (orig.)

  11. Normal hepatic and splenic size in children: Scintigraphic determination

    Energy Technology Data Exchange (ETDEWEB)

    Markisz, J.A.; Treves, S.T.; Davis, T.

    1987-05-01

    Measurements were made on sulfur colloid scintigrams of normal pediatric livers and spleens by analyzing 131 scans from 116 patients referred for liver or spleen trauma. Studies were used only if scans were normal, there was no history of malignancy or hepatic or splenic disease either prior to of after the study. Linear correlation was made with age, weight and both age and weight. All measured parameters correlated better with weight than with age, with vertical liver dimension exhibiting the best correlation (r=0.848). Multivariate analysis demonstrated uniformly better correlation of all measurements with both age and weight. Spleen and liver volumes were calculated assuming simple geometry, and showed excellent correlations. Graphical presentation of data will be useful in the clinical determination of hepatomegaly or splenomegaly in routine scintigraphy.

  12. Normal modes of vibration in nickel

    Energy Technology Data Exchange (ETDEWEB)

    Birgeneau, R J [Yale Univ., New Haven, Connecticut (United States); Cordes, J [Cambridge Univ., Cambridge (United Kingdom); Dolling, G; Woods, A D B

    1964-07-01

    The frequency-wave-vector dispersion relation, {nu}(q), for the normal vibrations of a nickel single crystal at 296{sup o}K has been measured for the [{zeta}00], [{zeta}00], [{zeta}{zeta}{zeta}], and [0{zeta}1] symmetric directions using inelastic neutron scattering. The results can be described in terms of the Born-von Karman theory of lattice dynamics with interactions out to fourth-nearest neighbors. The shapes of the dispersion curves are very similar to those of copper, the normal mode frequencies in nickel being about 1.24 times the corresponding frequencies in copper. The fourth-neighbor model was used to calculate the frequency distribution function g({nu}) and related thermodynamic properties. (author)

  13. Meta-analysis of prediction model performance across multiple studies: Which scale helps ensure between-study normality for the C-statistic and calibration measures?

    Science.gov (United States)

    Snell, Kym Ie; Ensor, Joie; Debray, Thomas Pa; Moons, Karel Gm; Riley, Richard D

    2017-01-01

    If individual participant data are available from multiple studies or clusters, then a prediction model can be externally validated multiple times. This allows the model's discrimination and calibration performance to be examined across different settings. Random-effects meta-analysis can then be used to quantify overall (average) performance and heterogeneity in performance. This typically assumes a normal distribution of 'true' performance across studies. We conducted a simulation study to examine this normality assumption for various performance measures relating to a logistic regression prediction model. We simulated data across multiple studies with varying degrees of variability in baseline risk or predictor effects and then evaluated the shape of the between-study distribution in the C-statistic, calibration slope, calibration-in-the-large, and E/O statistic, and possible transformations thereof. We found that a normal between-study distribution was usually reasonable for the calibration slope and calibration-in-the-large; however, the distributions of the C-statistic and E/O were often skewed across studies, particularly in settings with large variability in the predictor effects. Normality was vastly improved when using the logit transformation for the C-statistic and the log transformation for E/O, and therefore we recommend these scales to be used for meta-analysis. An illustrated example is given using a random-effects meta-analysis of the performance of QRISK2 across 25 general practices.

  14. Normal pressure hydrocephalus. Influences on cerebral hemodynamic and cerebrospinal fluid pressure--chemical autoregulation

    International Nuclear Information System (INIS)

    Meyer, J.S.; Tachibana, H.; Hardenberg, J.P.; Dowell, R.E. Jr.; Kitagawa, Y.; Mortel, K.F.

    1984-01-01

    Blood flow in the cerebral gray matter was measured in normal pressure hydrocephalus and Alzheimer disease by 133Xe inhalation. Flow values in the frontal and temporal gray matter increased after lowering cerebrospinal fluid (CSF) pressure by lumbar puncture in normal pressure hydrocephalus (p less than 0.05) and also after shunting. One case with cerebral complications did not improve clinically. In Alzheimer disease the reverse (decreases in flow in the gray matter) occurred after removal of CSF. Normal pressure hydrocephalus was associated with impaired cerebral vasomotor responsiveness during 100% oxygen and 5% carbon dioxide inhalation. This complication was restored toward normal after CSF removal and/or shunting. Cerebral blood flow measurements appear to be useful for confirming the diagnosis of normal pressure hydrocephalus and predicting the clinical benefit from shunting

  15. MUSIC-characterization of small scatterers for normal measurement data

    Science.gov (United States)

    Griesmaier, Roland; Hanke, Martin

    2009-07-01

    We investigate the reconstruction of the positions of a collection of small metallic objects buried beneath the ground from measurements of the vertical component of scattered fields corresponding to vertically polarized dipole excitations on a horizontal two-dimensional measurement device above the surface of the ground. A MUSIC reconstruction method for this problem has recently been proposed by Iakovleva et al (2007 IEEE Trans. Antennas Propag. 55 2598). In this paper, we give a rigorous theoretical justification of this method. To that end we prove a characterization of the positions of the scatterers in terms of the measurement data, applying an asymptotic analysis of the scattered fields. We present numerical results to illustrate our theoretical findings.

  16. MUSIC-characterization of small scatterers for normal measurement data

    International Nuclear Information System (INIS)

    Griesmaier, Roland; Hanke, Martin

    2009-01-01

    We investigate the reconstruction of the positions of a collection of small metallic objects buried beneath the ground from measurements of the vertical component of scattered fields corresponding to vertically polarized dipole excitations on a horizontal two-dimensional measurement device above the surface of the ground. A MUSIC reconstruction method for this problem has recently been proposed by Iakovleva et al (2007 IEEE Trans. Antennas Propag. 55 2598). In this paper, we give a rigorous theoretical justification of this method. To that end we prove a characterization of the positions of the scatterers in terms of the measurement data, applying an asymptotic analysis of the scattered fields. We present numerical results to illustrate our theoretical findings

  17. Video capsule endoscopy after bariatric and gastric surgery: oral ingestion is associated with satisfactory completion rate.

    Science.gov (United States)

    Stanich, Peter P; Kleinman, Bryan; Porter, Kyle M; Meyer, Marty M

    2015-01-01

    To investigate the outcomes of video capsule endoscopy (VCE) performed on patients after bariatric and gastric surgery with a focus on delivery method (oral ingestion or endoscopic placement). There is minimal published data regarding the use of VCE in patients after bariatric and gastric surgery and the optimal delivery method is unknown. Retrospective case series of patients with bariatric or gastric surgery undergoing VCE in a tertiary care center over 3 years. Outcomes of interest were completion of the procedure and bowel transit times. Twenty-three patients met study criteria. They underwent 24 VCE in the study period, with 13/16 (81.3%; 95% CI, 54%-96%) completed to the colon after oral ingestion and 5/8 (62.5%; 95% CI, 24%-91%) completed after endoscopic deployment. The median gastric transit time after oral ingestion was 440) (P=0.48). There were no instances of capsule retention. Oral ingestion of VCE resulted in a satisfactory completion rate with rapid gastric transit after bariatric and gastric surgery. There were no capsule retention events. Given this and the favorable risk and cost profile, oral ingestion should be favored over endoscopic placement in this patient population.

  18. Compliance of the normal-sized aorta in adolescents with Marfan syndrome: comparison of MR measurements of aortic distensibility and pulse wave velocity

    International Nuclear Information System (INIS)

    Eichhorn, J.G.; Ruediger, H.J.; Gorenflo, M.; Khalil, M.; Ulmer, H.; Krissak, R.; Kauczor, H.U.; Ley, S.; Universitaetsklinik Heidelberg; Arnold, R.; Universitaetskinderklinik Freiburg; Boese, J.; Siemens AG, Medical Solutions, Forchheim; Krug, R.; Fink, C.

    2007-01-01

    Purpose: To compare the aortic compliance of the normal-sized aorta of adolescents with Marfan syndrome and healthy controls using MR measurements of the aortic distensibility and pulse wave velocity. Materials and Methods: Fourteen patients (median age: 15 [9-21] years) and 11 healthy subjects (23 [12-32] years) were examined at 1.5 T. The MR protocol included 2D steady-state free precession (SSFP)-CINE MRI of the aortic distensibility and PC-MRI of the pulse wave velocity. All measurements were positioned perpendicular to the descending aorta at the level of the diaphragm for assessing the changes in the aortic cross-sectional areas and additionally above and below this plane for assessing the pulse wave velocity. In addition contrast-enhanced 3D-MR angiography was performed in adolescents with Marfan syndrome to exclude morphologic changes and to prove normal-sized aorta. Results: Compared with control subjects, adolescents with Marfan syndrome had significantly decreased distensibility and significantly increased pulse wave velocity (χ 2 -test, p = 0.0002) using an age-related non-linear regression analysis. The related aortic compliance was significantly decreased (χ 2 -test, p = 0.0002). There was a good correlation between the two methods (r = 0.86). A low intraobserver variability was found for both methods (≤ 2 %). (orig.)

  19. A new method for measuring aerosol nebulizers output using radioactive tracers

    International Nuclear Information System (INIS)

    Gatnash, A.A.; Connolly, C.K.; Chandler, S.T.

    1998-01-01

    Reproducibility and comparability of bronchial challenge tests depends critically on accurate assessment of nebulizers output. Evaporation during nebulization means that simple weighing is inaccurate, overestimating the delivered dose of active ingredient. We wanted to quantify this effect in the context of intermittent nebulization, using a dosimeter as used in bronchial provocation tests. Output of three types of nebulizers, from the MEFAR dosimeter, was measured by radioactive tracer, using a standard solution of technetium-99m-pertechnetate (1.5 kBq x mL -1 ) in 4 mL of normal saline. The aerosol was impacted by suction onto a micro filter, and the radioactivity measured. Nebulizers were weighed before and after nebulization. Ratio of nebulized volume calculated from the radioactivity on the filter, to the total volume loss by weight, was expressed as nebulized ratio. The effect on output of two concentrations of methacholine, two tracers of different weights, and change in temperature, were assessed. Nebulized ratio varied between 44.1-71.6%. Results were more consistent within the same type of nebulizer than between different makes. Neither changes in molar concentration nor molecular weight affected nebulizer output or nebulized ratio. Mean nebulized ratio was 58.5%, showing that calibration by weighing, overestimates the delivered dose by a factor of approximately two. Measuring radioactivity eluted from a micro filter, onto which nebulized output had been impacted proved to be a satisfactory method of calibration. (au)

  20. Effect of Image Linearization on Normalized Compression Distance

    Science.gov (United States)

    Mortensen, Jonathan; Wu, Jia Jie; Furst, Jacob; Rogers, John; Raicu, Daniela

    Normalized Information Distance, based on Kolmogorov complexity, is an emerging metric for image similarity. It is approximated by the Normalized Compression Distance (NCD) which generates the relative distance between two strings by using standard compression algorithms to compare linear strings of information. This relative distance quantifies the degree of similarity between the two objects. NCD has been shown to measure similarity effectively on information which is already a string: genomic string comparisons have created accurate phylogeny trees and NCD has also been used to classify music. Currently, to find a similarity measure using NCD for images, the images must first be linearized into a string, and then compared. To understand how linearization of a 2D image affects the similarity measure, we perform four types of linearization on a subset of the Corel image database and compare each for a variety of image transformations. Our experiment shows that different linearization techniques produce statistically significant differences in NCD for identical spatial transformations.

  1. The experience of weight management in normal weight adults.

    Science.gov (United States)

    Hernandez, Cheri Ann; Hernandez, David A; Wellington, Christine M; Kidd, Art

    2016-11-01

    No prior research has been done with normal weight persons specific to their experience of weight management. The purpose of this research was to discover the experience of weight management in normal weight individuals. Glaserian grounded theory was used. Qualitative data (focus group) and quantitative data (food diary, study questionnaire, and anthropometric measures) were collected. Weight management was an ongoing process of trying to focus on living (family, work, and social), while maintaining their normal weight targets through five consciously and unconsciously used strategies. Despite maintaining normal weights, the nutritional composition of foods eaten was grossly inadequate. These five strategies can be used to develop new weight management strategies that could be integrated into existing weight management programs, or could be developed into novel weight management interventions. Surprisingly, normal weight individuals require dietary assessment and nutrition education to prevent future negative health consequences. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Experimental studies of breaking of elastic tired wheel under variable normal load

    Science.gov (United States)

    Fedotov, A. I.; Zedgenizov, V. G.; Ovchinnikova, N. I.

    2017-10-01

    The paper analyzes the braking of a vehicle wheel subjected to disturbances of normal load variations. Experimental tests and methods for developing test modes as sinusoidal force disturbances of the normal wheel load were used. Measuring methods for digital and analogue signals were used as well. Stabilization of vehicle wheel braking subjected to disturbances of normal load variations is a topical issue. The paper suggests a method for analyzing wheel braking processes under disturbances of normal load variations. A method to control wheel baking processes subjected to disturbances of normal load variations was developed.

  3. Development and Validation of a Self-Report Measure of Mentalizing: The Reflective Functioning Questionnaire.

    Directory of Open Access Journals (Sweden)

    Peter Fonagy

    Full Text Available Reflective functioning or mentalizing is the capacity to interpret both the self and others in terms of internal mental states such as feelings, wishes, goals, desires, and attitudes. This paper is part of a series of papers outlining the development and psychometric features of a new self-report measure, the Reflective Functioning Questionnaire (RFQ, designed to provide an easy to administer self-report measure of mentalizing. We describe the development and initial validation of the RFQ in three studies. Study 1 focuses on the development of the RFQ, its factor structure and construct validity in a sample of patients with Borderline Personality Disorder (BPD and Eating Disorder (ED (n = 108 and normal controls (n = 295. Study 2 aims to replicate these findings in a fresh sample of 129 patients with personality disorder and 281 normal controls. Study 3 addresses the relationship between the RFQ, parental reflective functioning and infant attachment status as assessed with the Strange Situation Procedure (SSP in a sample of 136 community mothers and their infants. In both Study 1 and 2, confirmatory factor analyses yielded two factors assessing Certainty (RFQ_C and Uncertainty (RFQ_U about the mental states of self and others. These two factors were relatively distinct, invariant across clinical and non-clinical samples, had satisfactory internal consistency and test-retest stability, and were largely unrelated to demographic features. The scales discriminated between patients and controls, and were significantly and in theoretically predicted ways correlated with measures of empathy, mindfulness and perspective-taking, and with both self-reported and clinician-reported measures of borderline personality features and other indices of maladaptive personality functioning. Furthermore, the RFQ scales were associated with levels of parental reflective functioning, which in turn predicted infant attachment status in the SSP. Overall, this study lends

  4. Satisfactory reliability among nursing students using the instrument PVC ASSESS to evaluate management of peripheral venous catheters.

    Science.gov (United States)

    Ahlqvist, Margary; Berglund, Britta; Nordström, Gun; Klang, Birgitta; Johansson, Eva

    2014-01-01

    Nursing students should be given opportunities to participate in clinical audits during their education. However, audit tools are seldom tested for reliability among nursing students. The aim of this study was to present reliability among nursing students using the instrument PVC assess to assess management of peripheral venous catheters (PVCs) and PVC-related signs of thrombophlebitis. PVC assess was used to assess 67 inserted PVCs in 60 patients at ten wards at a university hospital. One group of nursing students (n=4) assessed PVCs at the bedside (inter-rater reliability) and photographs of these PVCs were taken. Another group of students (n=3) assessed the PVCs in the photographs after 4 weeks (test-retest reliability). To determine reliability, proportion of agreement [P(A)] and Cohen's kappa coefficient (κ) were calculated. For bedside assessment of PVCs, P(A) ranged from good to excellent (0.80-1.0) in 55% of the 26 PVC assess items that were tested. P(A) was poor (satisfactory reliability among nursing students. However, students need training in how to use the instrument before assessing PVCs.

  5. Evaluation of Normalization Methods to Pave the Way Towards Large-Scale LC-MS-Based Metabolomics Profiling Experiments

    Science.gov (United States)

    Valkenborg, Dirk; Baggerman, Geert; Vanaerschot, Manu; Witters, Erwin; Dujardin, Jean-Claude; Burzykowski, Tomasz; Berg, Maya

    2013-01-01

    Abstract Combining liquid chromatography-mass spectrometry (LC-MS)-based metabolomics experiments that were collected over a long period of time remains problematic due to systematic variability between LC-MS measurements. Until now, most normalization methods for LC-MS data are model-driven, based on internal standards or intermediate quality control runs, where an external model is extrapolated to the dataset of interest. In the first part of this article, we evaluate several existing data-driven normalization approaches on LC-MS metabolomics experiments, which do not require the use of internal standards. According to variability measures, each normalization method performs relatively well, showing that the use of any normalization method will greatly improve data-analysis originating from multiple experimental runs. In the second part, we apply cyclic-Loess normalization to a Leishmania sample. This normalization method allows the removal of systematic variability between two measurement blocks over time and maintains the differential metabolites. In conclusion, normalization allows for pooling datasets from different measurement blocks over time and increases the statistical power of the analysis, hence paving the way to increase the scale of LC-MS metabolomics experiments. From our investigation, we recommend data-driven normalization methods over model-driven normalization methods, if only a few internal standards were used. Moreover, data-driven normalization methods are the best option to normalize datasets from untargeted LC-MS experiments. PMID:23808607

  6. Selecting between-sample RNA-Seq normalization methods from the perspective of their assumptions.

    Science.gov (United States)

    Evans, Ciaran; Hardin, Johanna; Stoebel, Daniel M

    2017-02-27

    RNA-Seq is a widely used method for studying the behavior of genes under different biological conditions. An essential step in an RNA-Seq study is normalization, in which raw data are adjusted to account for factors that prevent direct comparison of expression measures. Errors in normalization can have a significant impact on downstream analysis, such as inflated false positives in differential expression analysis. An underemphasized feature of normalization is the assumptions on which the methods rely and how the validity of these assumptions can have a substantial impact on the performance of the methods. In this article, we explain how assumptions provide the link between raw RNA-Seq read counts and meaningful measures of gene expression. We examine normalization methods from the perspective of their assumptions, as an understanding of methodological assumptions is necessary for choosing methods appropriate for the data at hand. Furthermore, we discuss why normalization methods perform poorly when their assumptions are violated and how this causes problems in subsequent analysis. To analyze a biological experiment, researchers must select a normalization method with assumptions that are met and that produces a meaningful measure of expression for the given experiment. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Normalization: A Preprocessing Stage

    OpenAIRE

    Patro, S. Gopal Krishna; Sahu, Kishore Kumar

    2015-01-01

    As we know that the normalization is a pre-processing stage of any type problem statement. Especially normalization takes important role in the field of soft computing, cloud computing etc. for manipulation of data like scale down or scale up the range of data before it becomes used for further stage. There are so many normalization techniques are there namely Min-Max normalization, Z-score normalization and Decimal scaling normalization. So by referring these normalization techniques we are ...

  8. Making nuclear 'normal'

    International Nuclear Information System (INIS)

    Haehlen, Peter; Elmiger, Bruno

    2000-01-01

    The mechanics of the Swiss NPPs' 'come and see' programme 1995-1999 were illustrated in our contributions to all PIME workshops since 1996. Now, after four annual 'waves', all the country has been covered by the NPPs' invitation to dialogue. This makes PIME 2000 the right time to shed some light on one particular objective of this initiative: making nuclear 'normal'. The principal aim of the 'come and see' programme, namely to give the Swiss NPPs 'a voice of their own' by the end of the nuclear moratorium 1990-2000, has clearly been attained and was commented on during earlier PIMEs. It is, however, equally important that Swiss nuclear energy not only made progress in terms of public 'presence', but also in terms of being perceived as a normal part of industry, as a normal branch of the economy. The message that Swiss nuclear energy is nothing but a normal business involving normal people, was stressed by several components of the multi-prong campaign: - The speakers in the TV ads were real - 'normal' - visitors' guides and not actors; - The testimonials in the print ads were all real NPP visitors - 'normal' people - and not models; - The mailings inviting a very large number of associations to 'come and see' activated a typical channel of 'normal' Swiss social life; - Spending money on ads (a new activity for Swiss NPPs) appears to have resulted in being perceived by the media as a normal branch of the economy. Today we feel that the 'normality' message has well been received by the media. In the controversy dealing with antinuclear arguments brought forward by environmental organisations journalists nowadays as a rule give nuclear energy a voice - a normal right to be heard. As in a 'normal' controversy, the media again actively ask themselves questions about specific antinuclear claims, much more than before 1990 when the moratorium started. The result is that in many cases such arguments are discarded by journalists, because they are, e.g., found to be

  9. Diurnal levels of immunoreactive erythropoietin in normal subjects and subjects with chronic lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Miller, M.E.; Garcia, J.F.; Cohen, R.A.; Cronkite, E.P.; Moccia, G.; Acevedo, J.

    1981-10-01

    Serum levels of immunoreactive erythropoietin (Ep) were measured in 48 normal male and female volunteers, ages 20-60 years, to establish a control value for Ep of 18.5 +/- 5.0 (mean +/- SD) mU/ml. Levels of the hormone were also measured sequentially over a 24 h period of time in an additional 17 normal volunteers with no diurnal variation. Diurnal levels of immunoreactive Ep were also measured in 30 subjects, with chronic lung disease. These patients, in contrast to normal subjects exhibited a diurnal variation in the level of immunoreactive Ep with peak levels occurring at midnight. The only variable measured which correlated with the serum immunoreactive Ep level in subjects with chronic lung disease was the level of carboxyhaemoglobin (P less than 0.02).

  10. Metabolomics data normalization with EigenMS.

    Directory of Open Access Journals (Sweden)

    Yuliya V Karpievitch

    Full Text Available Liquid chromatography mass spectrometry has become one of the analytical platforms of choice for metabolomics studies. However, LC-MS metabolomics data can suffer from the effects of various systematic biases. These include batch effects, day-to-day variations in instrument performance, signal intensity loss due to time-dependent effects of the LC column performance, accumulation of contaminants in the MS ion source and MS sensitivity among others. In this study we aimed to test a singular value decomposition-based method, called EigenMS, for normalization of metabolomics data. We analyzed a clinical human dataset where LC-MS serum metabolomics data and physiological measurements were collected from thirty nine healthy subjects and forty with type 2 diabetes and applied EigenMS to detect and correct for any systematic bias. EigenMS works in several stages. First, EigenMS preserves the treatment group differences in the metabolomics data by estimating treatment effects with an ANOVA model (multiple fixed effects can be estimated. Singular value decomposition of the residuals matrix is then used to determine bias trends in the data. The number of bias trends is then estimated via a permutation test and the effects of the bias trends are eliminated. EigenMS removed bias of unknown complexity from the LC-MS metabolomics data, allowing for increased sensitivity in differential analysis. Moreover, normalized samples better correlated with both other normalized samples and corresponding physiological data, such as blood glucose level, glycated haemoglobin, exercise central augmentation pressure normalized to heart rate of 75, and total cholesterol. We were able to report 2578 discriminatory metabolite peaks in the normalized data (p<0.05 as compared to only 1840 metabolite signals in the raw data. Our results support the use of singular value decomposition-based normalization for metabolomics data.

  11. Phenotype of normal spirometry in an aging population.

    Science.gov (United States)

    Vaz Fragoso, Carlos A; McAvay, Gail; Van Ness, Peter H; Casaburi, Richard; Jensen, Robert L; MacIntyre, Neil; Gill, Thomas M; Yaggi, H Klar; Concato, John

    2015-10-01

    In aging populations, the commonly used Global Initiative for Chronic Obstructive Lung Disease (GOLD) may misclassify normal spirometry as respiratory impairment (airflow obstruction and restrictive pattern), including the presumption of respiratory disease (chronic obstructive pulmonary disease [COPD]). To evaluate the phenotype of normal spirometry as defined by a new approach from the Global Lung Initiative (GLI), overall and across GOLD spirometric categories. Using data from COPDGene (n = 10,131; ages 45-81; smoking history, ≥10 pack-years), we evaluated spirometry and multiple phenotypes, including dyspnea severity (Modified Medical Research Council grade 0-4), health-related quality of life (St. George's Respiratory Questionnaire total score), 6-minute-walk distance, bronchodilator reversibility (FEV1 % change), computed tomography-measured percentage of lung with emphysema (% emphysema) and gas trapping (% gas trapping), and small airway dimensions (square root of the wall area for a standardized airway with an internal perimeter of 10 mm). Among 5,100 participants with GLI-defined normal spirometry, GOLD identified respiratory impairment in 1,146 (22.5%), including a restrictive pattern in 464 (9.1%), mild COPD in 380 (7.5%), moderate COPD in 302 (5.9%), and severe COPD in none. Overall, the phenotype of GLI-defined normal spirometry included normal adjusted mean values for dyspnea grade (0.8), St. George's Respiratory Questionnaire (15.9), 6-minute-walk distance (1,424 ft [434 m]), bronchodilator reversibility (2.7%), % emphysema (0.9%), % gas trapping (10.7%), and square root of the wall area for a standardized airway with an internal perimeter of 10 mm (3.65 mm); corresponding 95% confidence intervals were similarly normal. These phenotypes remained normal for GLI-defined normal spirometry across GOLD spirometric categories. GLI-defined normal spirometry, even when classified as respiratory impairment by GOLD, included adjusted mean values in the

  12. Development of PC based Monte Carlo simulations for the calculation of scanner-specific normalized organ doses from CT

    International Nuclear Information System (INIS)

    Jansen, J. T. M.; Shrimpton, P. C.; Zankl, M.

    2009-01-01

    This paper discusses the simulation of contemporary computed tomography (CT) scanners using Monte Carlo calculation methods to derive normalized organ doses, which enable hospital physicists to estimate typical organ and effective doses for CT examinations. The hardware used in a small PC-cluster at the Health Protection Agency (HPA) for these calculations is described. Investigations concerning optimization of software, including the radiation transport codes MCNP5 and MCNPX, and the Intel and PGI FORTRAN compilers, are presented in relation to results and calculation speed. Differences in approach for modelling the X-ray source are described and their influences are analysed. Comparisons with previously published calculations at HPA from the early 1990's proved satisfactory for the purposes of quality assurance and are presented in terms of organ dose ratios for whole body exposure and differences in organ location. Influences on normalized effective dose are discussed in relation to choice of cross section library, CT scanner technology (contemporary multi slice versus single slice), definition for effective dose (1990 and 2007 versions) and anthropomorphic phantom (mathematical and voxel). The results illustrate the practical need for the updated scanner-specific dose coefficients presently being calculated at HPA, in order to facilitate improved dosimetry for contemporary CT practice. (authors)

  13. Kullback–Leibler Divergence of the γ–ordered Normal over t–distribution

    OpenAIRE

    Toulias, T-L.; Kitsos, C-P.

    2012-01-01

    The aim of this paper is to evaluate and study the Kullback–Leibler divergence of the γ–ordered Normal distribution, a generalization of Normal distribution emerged from the generalized Fisher’s information measure, over the scaled t–distribution. We investigate this evaluation through a series of bounds and approximations while the asymptotic behavior of the divergence is also studied. Moreover, we obtain a generalization of the known Kullback–Leibler information measure betwe...

  14. Normal ranges and test-retest reproducibility of flow and velocity parameters in intracranial arteries measured with phase-contrast magnetic resonance imaging

    International Nuclear Information System (INIS)

    Correia de Verdier, Maria; Wikstroem, Johan

    2016-01-01

    The purpose of the present study was to investigate normal ranges and test-retest reproducibility of phase-contrast MRI (PC-MRI)-measured flow and velocity parameters in intracranial arteries. Highest flow (HF), lowest flow (LF), peak systolic velocity (PSV), and end diastolic velocity (EDV) were measured at two dates in the anterior (ACA), middle (MCA), and posterior (PCA) cerebral arteries of 30 healthy volunteers using two-dimensional PC-MRI at 3 T. Least detectable difference (LDD) was calculated. In the left ACA, HF was (mean (range, LDD)) 126 ml/min (36-312, 59 %), LF 61 ml/min (0-156, 101 %), PSV 64 cm/s (32-141, 67 %), and EDV 35 cm/s (18-55, 42 %); in the right ACA, HF was 154 ml/min (42-246, 49 %), LF 77 ml/min (0-156, 131 %), PSV 75 cm/s (26-161, 82 %), and EDV 39 cm/s (7-59, 67 %). In the left MCA, HF was 235 ml/min (126-372, 35 %), LF 116 ml/min (42-186, 48 %), PSV 90 cm/s (55-183, 39 %), and EDV 46 cm/s (20-66, 28 %); in the right MCA, HF was 238 ml/min (162-342, 44 %), LF 120 ml/min (72-216, 48 %), PSV 88 cm/s (55-141, 35 %), and EDV 45 cm/s (26-67, 23 %). In the left PCA, HF was 108 ml/min (42-168, 54 %), LF 53 ml/min (18-108, 64 %), PSV 50 cm/s (24-77, 63 %), and EDV 28 cm/s (14-40, 45 %); in the right PCA, HF was 98 ml/min (30-162, 49 %), LF 49 ml/min (12-84, 55 %), PSV 47 cm/s (27-88, 59 %), and EDV 27 cm/s (16-41, 45 %). PC-MRI-measured flow and velocity parameters in the main intracranial arteries have large normal ranges. Reproducibility is highest in MCA. (orig.)

  15. Normal ranges and test-retest reproducibility of flow and velocity parameters in intracranial arteries measured with phase-contrast magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Correia de Verdier, Maria; Wikstroem, Johan [Uppsala University Hospital, Department of Radiology, Uppsala University, Uppsala (Sweden)

    2016-05-15

    The purpose of the present study was to investigate normal ranges and test-retest reproducibility of phase-contrast MRI (PC-MRI)-measured flow and velocity parameters in intracranial arteries. Highest flow (HF), lowest flow (LF), peak systolic velocity (PSV), and end diastolic velocity (EDV) were measured at two dates in the anterior (ACA), middle (MCA), and posterior (PCA) cerebral arteries of 30 healthy volunteers using two-dimensional PC-MRI at 3 T. Least detectable difference (LDD) was calculated. In the left ACA, HF was (mean (range, LDD)) 126 ml/min (36-312, 59 %), LF 61 ml/min (0-156, 101 %), PSV 64 cm/s (32-141, 67 %), and EDV 35 cm/s (18-55, 42 %); in the right ACA, HF was 154 ml/min (42-246, 49 %), LF 77 ml/min (0-156, 131 %), PSV 75 cm/s (26-161, 82 %), and EDV 39 cm/s (7-59, 67 %). In the left MCA, HF was 235 ml/min (126-372, 35 %), LF 116 ml/min (42-186, 48 %), PSV 90 cm/s (55-183, 39 %), and EDV 46 cm/s (20-66, 28 %); in the right MCA, HF was 238 ml/min (162-342, 44 %), LF 120 ml/min (72-216, 48 %), PSV 88 cm/s (55-141, 35 %), and EDV 45 cm/s (26-67, 23 %). In the left PCA, HF was 108 ml/min (42-168, 54 %), LF 53 ml/min (18-108, 64 %), PSV 50 cm/s (24-77, 63 %), and EDV 28 cm/s (14-40, 45 %); in the right PCA, HF was 98 ml/min (30-162, 49 %), LF 49 ml/min (12-84, 55 %), PSV 47 cm/s (27-88, 59 %), and EDV 27 cm/s (16-41, 45 %). PC-MRI-measured flow and velocity parameters in the main intracranial arteries have large normal ranges. Reproducibility is highest in MCA. (orig.)

  16. How Can Polarization States of Reflected Light from Snow Surfaces Inform Us on Surface Normals and Ultimately Snow Grain Size Measurements?

    Science.gov (United States)

    Schneider, A. M.; Flanner, M.; Yang, P.; Yi, B.; Huang, X.; Feldman, D.

    2016-12-01

    The Snow Grain Size and Pollution (SGSP) algorithm is a method applied to Moderate Resolution Imaging Spectroradiometer data to estimate snow grain size from space-borne measurements. Previous studies validate and quantify potential sources of error in this method, but because it assumes flat snow surfaces, however, large scale variations in surface normals can cause biases in its estimates due to its dependence on solar and observation zenith angles. To address these variations, we apply the Monte Carlo method for photon transport using data containing the single scattering properties of different ice crystals to calculate polarization states of reflected monochromatic light at 1500nm from modeled snow surfaces. We evaluate the dependence of these polarization states on solar and observation geometry at 1500nm because multiple scattering is generally a mechanism for depolarization and the ice crystals are relatively absorptive at this wavelength. Using 1500nm thus results in a higher number of reflected photons undergoing fewer scattering events, increasing the likelihood of reflected light having higher degrees of polarization. In evaluating the validity of the model, we find agreement with previous studies pertaining to near-infrared spectral directional hemispherical reflectance (i.e. black-sky albedo) and similarities in measured bidirectional reflectance factors, but few studies exist modeling polarization states of reflected light from snow surfaces. Here, we present novel results pertaining to calculated polarization states and compare dependences on solar and observation geometry for different idealized snow surfaces. If these dependencies are consistent across different ice particle shapes and sizes, then these findings could inform the SGSP algorithm by providing useful relationships between measurable physical quantities and solar and observation geometry to better understand variations in snow surface normals from remote sensing observations.

  17. Computing Instantaneous Frequency by normalizing Hilbert Transform

    Science.gov (United States)

    Huang, Norden E.

    2005-05-31

    This invention presents Normalized Amplitude Hilbert Transform (NAHT) and Normalized Hilbert Transform(NHT), both of which are new methods for computing Instantaneous Frequency. This method is designed specifically to circumvent the limitation set by the Bedorsian and Nuttal Theorems, and to provide a sharp local measure of error when the quadrature and the Hilbert Transform do not agree. Motivation for this method is that straightforward application of the Hilbert Transform followed by taking the derivative of the phase-angle as the Instantaneous Frequency (IF) leads to a common mistake made up to this date. In order to make the Hilbert Transform method work, the data has to obey certain restrictions.

  18. Photometric normalization of LROC WAC images

    Science.gov (United States)

    Sato, H.; Denevi, B.; Robinson, M. S.; Hapke, B. W.; McEwen, A. S.; LROC Science Team

    2010-12-01

    variability of the regolith from region to region. As the fitting area increases, the accuracy of curve fitting decreases due to the larger variety of albedo, topography, and composition. Thus we have adopted an albedo-dependent photometric normalization routine. Phase curves are derived for discreet bins of preliminary normalized reflectance calculated from Clementine global mosaic in a fitting area that is composed of predominantly mare in Oceanus Procellarum. The global WAC mosaic was then corrected pixel-by-pixel according to its preliminary reflectance map with satisfactory results. We observed that the phase curves per normalized-reflectance bins become steeper as the reflectance value increases. Further filtering by using FeO, TiO2, or optical maturity [5] for parameter calculations may help elucidate the effects of surface composition and maturity on photometric properties of the surface. [1] Hapke, B.W. (1993) Theory of Reflectance and Emittance Spectroscopy, Cambridge Univ. Press. [2] Schoenberg (1925) Ada. Soc. Febb., vol. 50. [3] Hillier et al. (1999) Icarus 141, 205-225. [4] McEwen (1991) Icarus 92, 298-311. [5] Lucey et al. (2000) JGR, v105, no E8, p20377-20386.

  19. MRI characterization of brown adipose tissue in obese and normal-weight children

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Jie; Rigsby, Cynthia K.; Shore, Richard M. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging, 225 E. Chicago Ave., Box 9, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Schoeneman, Samantha E. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging, 225 E. Chicago Ave., Box 9, Chicago, IL (United States); Zhang, Huiyuan [John H. Stroger, Jr. Hospital of Cook County, Collaborative Research Unit, Chicago, IL (United States); Kwon, Soyang [Ann and Robert H. Lurie Children' s Hospital of Chicago, Stanley Manne Children' s Research Institute, Chicago, IL (United States); Northwestern University, Department of Pediatrics, Feinberg School of Medicine, Chicago, IL (United States); Josefson, Jami L. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Division of Endocrinology, Chicago, IL (United States); Northwestern University, Department of Pediatrics, Feinberg School of Medicine, Chicago, IL (United States)

    2015-10-15

    Brown adipose tissue (BAT) is identified in mammals as an adaptive thermogenic organ for modulation of energy expenditure and heat generation. Human BAT may be primarily composed of brown-in-white (BRITE) adipocytes and stimulation of BRITE may serve as a potential target for obesity interventions. Current imaging studies of BAT detection and characterization have been mainly limited to PET/CT. MRI is an emerging application for BAT characterization in healthy children. To exploit Dixon and diffusion-weighted MRI methods to characterize cervical-supraclavicular BAT/BRITE properties in normal-weight and obese children while accounting for pubertal status. Twenty-eight healthy children (9-15 years old) with a normal or obese body mass index participated. MRI exams were performed to characterize supraclavicular adipose tissues by measuring tissue fat percentage, T2*, tissue water mobility, and microvasculature properties. We used multivariate linear regression models to compare tissue properties between normal-weight and obese groups while accounting for pubertal status. MRI measurements of BAT/BRITE tissues in obese children showed higher fat percentage (P < 0.0001), higher T2* (P < 0.0001), and lower diffusion coefficient (P = 0.015) compared with normal-weight children. Pubertal status was a significant covariate for the T2* measurement, with higher T2* (P = 0.0087) in pubertal children compared to prepubertal children. Perfusion measurements varied by pubertal status. Compared to normal-weight children, obese prepubertal children had lower perfusion fraction (P = 0.003) and pseudo-perfusion coefficient (P = 0.048); however, obese pubertal children had higher perfusion fraction (P = 0.02) and pseudo-perfusion coefficient (P = 0.028). This study utilized chemical-shift Dixon MRI and diffusion-weighted MRI methods to characterize supraclavicular BAT/BRITE tissue properties. The multi-parametric evaluation revealed evidence of morphological differences in brown

  20. MRI characterization of brown adipose tissue in obese and normal-weight children

    International Nuclear Information System (INIS)

    Deng, Jie; Rigsby, Cynthia K.; Shore, Richard M.; Schoeneman, Samantha E.; Zhang, Huiyuan; Kwon, Soyang; Josefson, Jami L.

    2015-01-01

    Brown adipose tissue (BAT) is identified in mammals as an adaptive thermogenic organ for modulation of energy expenditure and heat generation. Human BAT may be primarily composed of brown-in-white (BRITE) adipocytes and stimulation of BRITE may serve as a potential target for obesity interventions. Current imaging studies of BAT detection and characterization have been mainly limited to PET/CT. MRI is an emerging application for BAT characterization in healthy children. To exploit Dixon and diffusion-weighted MRI methods to characterize cervical-supraclavicular BAT/BRITE properties in normal-weight and obese children while accounting for pubertal status. Twenty-eight healthy children (9-15 years old) with a normal or obese body mass index participated. MRI exams were performed to characterize supraclavicular adipose tissues by measuring tissue fat percentage, T2*, tissue water mobility, and microvasculature properties. We used multivariate linear regression models to compare tissue properties between normal-weight and obese groups while accounting for pubertal status. MRI measurements of BAT/BRITE tissues in obese children showed higher fat percentage (P < 0.0001), higher T2* (P < 0.0001), and lower diffusion coefficient (P = 0.015) compared with normal-weight children. Pubertal status was a significant covariate for the T2* measurement, with higher T2* (P = 0.0087) in pubertal children compared to prepubertal children. Perfusion measurements varied by pubertal status. Compared to normal-weight children, obese prepubertal children had lower perfusion fraction (P = 0.003) and pseudo-perfusion coefficient (P = 0.048); however, obese pubertal children had higher perfusion fraction (P = 0.02) and pseudo-perfusion coefficient (P = 0.028). This study utilized chemical-shift Dixon MRI and diffusion-weighted MRI methods to characterize supraclavicular BAT/BRITE tissue properties. The multi-parametric evaluation revealed evidence of morphological differences in brown

  1. Witness sample preparation for measuring antireflection coatings.

    Science.gov (United States)

    Willey, Ronald R

    2014-02-01

    Measurement of antireflection coating of witness samples from across the worldwide industry has been shown to have excess variability from a sampling taken for the OSA Topical Meeting on Optical Interference Coatings: Measurement Problem. Various sample preparation techniques have been discussed with their limitations, and a preferred technique is recommended with its justification, calibration procedures, and limitations. The common practice of grinding the second side to reduce its reflection is less than satisfactory. One recommended practice is to paint the polished second side, which reduces its reflection to almost zero. A method to evaluate the suitability of given paints is also described.

  2. Quantification of differences between nailfold capillaroscopy images with a scleroderma pattern and normal pattern using measures of geometric and algorithmic complexity.

    Science.gov (United States)

    Urwin, Samuel George; Griffiths, Bridget; Allen, John

    2017-02-01

    This study aimed to quantify and investigate differences in the geometric and algorithmic complexity of the microvasculature in nailfold capillaroscopy (NFC) images displaying a scleroderma pattern and those displaying a 'normal' pattern. 11 NFC images were qualitatively classified by a capillary specialist as indicative of 'clear microangiopathy' (CM), i.e. a scleroderma pattern, and 11 as 'not clear microangiopathy' (NCM), i.e. a 'normal' pattern. Pre-processing was performed, and fractal dimension (FD) and Kolmogorov complexity (KC) were calculated following image binarisation. FD and KC were compared between groups, and a k-means cluster analysis (n  =  2) on all images was performed, without prior knowledge of the group assigned to them (i.e. CM or NCM), using FD and KC as inputs. CM images had significantly reduced FD and KC compared to NCM images, and the cluster analysis displayed promising results that the quantitative classification of images into CM and NCM groups is possible using the mathematical measures of FD and KC. The analysis techniques used show promise for quantitative microvascular investigation in patients with systemic sclerosis.

  3. Birkhoff normalization

    NARCIS (Netherlands)

    Broer, H.; Hoveijn, I.; Lunter, G.; Vegter, G.

    2003-01-01

    The Birkhoff normal form procedure is a widely used tool for approximating a Hamiltonian systems by a simpler one. This chapter starts out with an introduction to Hamiltonian mechanics, followed by an explanation of the Birkhoff normal form procedure. Finally we discuss several algorithms for

  4. Skin perfusion pressure measured with a photo sensor in an air-filled plastic balloon: validity and reproducibility on the lower leg in normal subjects and patients suspected of obliterative arterial disease

    DEFF Research Database (Denmark)

    Nielsen, Steen Levin; Nielsen, Anne Lerberg; Vind, Susanne Haase

    2011-01-01

    An inflatable small plastic bag including a photo sensor was constructed for measurement of skin perfusion pressure avoiding the rim of the photo sensor over bony and tendineous surfaces of the tibia below the knee, at the ankle, and on the dorsal forefoot. Compression was obtained using a conical...... blood pressure cuff with continuous decrease from suprasystolic arm pressure. The validity of skin perfusion pressure with the new device was compared to that of isotope washout below the knee in normal subjects and in patients with an ischemic forefoot with acceptable agreement. The method had a high...... reproducibility within and between days in normal subjects. Compared to systolic arterial pressure measured using a strain gauge with a cuff on the ankle in normal subjects and patients with intermittent claudication the new device showed blood pressure in the skin closer to the diastolic pressure. The new...

  5. The assessment of four different correction models applied to the diffuse radiation measured with a shadow ring using global and normal beam radiation measurements for Beer Sheva, Israel

    Energy Technology Data Exchange (ETDEWEB)

    Kudish, Avraham I.; Evseev, Efim G. [Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, E D Bergmann Campus, Beer Sheva 84105 (Israel)

    2008-02-15

    The measurement of the diffuse radiation incident on a horizontal surface, a priori a straightforward task, is fraught with difficulties. It is possible to measure the diffuse radiation by three different techniques: two of which measure it directly and the third indirectly. The most accurate is the indirect one, which is based upon the concurrent measurements of the horizontal global and the normal incidence beam radiation. The disadvantage of this being the relatively expensive tracking system required for measuring the latter. The diffuse radiation can be measured directly with a pyranometer outfitted with either an occulting disk or shadow ring, which prevent the beam radiation from impinging on the pyranometer sensor. The occulting disk can provide accurate measurements of the diffuse radiation but it requires a relatively expensive sun tracking system in the east-west axis. The shadow ring is a stationary device with regard to the east-west axis and blocks the beam radiation component by creating a permanent shadow on the pyranometer sensor. The major disadvantage of the shadow ring is that it also blocks that portion of the diffuse radiation obscured by the shadow ring. This introduces a measurement error that must be corrected to account for that portion of the sky obscured by the shadow band. In addition to this geometric correction factor there is a need to correct for anisotropic sky conditions. Four correction models have been applied to the data for Beer Sheva, Israel and the results have been evaluated both graphically and statistically. An attempt has been made to score the relative performance of the models under different sky conditions. (author)

  6. Normal Pressure Hydrocephalus (NPH)

    Science.gov (United States)

    ... local chapter Join our online community Normal Pressure Hydrocephalus (NPH) Normal pressure hydrocephalus is a brain disorder ... Symptoms Diagnosis Causes & risks Treatments About Normal Pressure Hydrocephalus Normal pressure hydrocephalus occurs when excess cerebrospinal fluid ...

  7. The Quantitative Measurements of Vascular Density and Flow Areas of Macula Using Optical Coherence Tomography Angiography in Normal Volunteers.

    Science.gov (United States)

    Ghassemi, Fariba; Fadakar, Kaveh; Bazvand, Fatemeh; Mirshahi, Reza; Mohebbi, Masoumeh; Sabour, Siamak

    2017-06-01

    The quantification of the density of macular vascular networks and blood flow areas in the foveal and parafoveal area in healthy subjects using optical coherence tomography angiography (OCTA). Cross-sectional, prospective study in an institutional setting at the Retina Services of Farabi Eye Hospital. One hundred twelve normal volunteers with no known ocular or systemic disease were included, including patient numbers (one or both eyes), selection procedures, inclusion/exclusion criteria, randomization procedure, and masking. En face angiogram OCTA was performed on a 3 mm × 3 mm region centered on the macula. Automated thresholding and measuring algorithm method for foveal and parafoveal blood flow and vascular density (VD) were used. The density of macular vascular networks and blood flow area in the foveal and parafoveal area were measured. A total of 224 healthy eyes from 112 subjects with a mean age of 36.4 years ± 11.3 years were included. In the foveal region, the VD of the superficial capillary network (sCN) was significantly higher than that of the deep capillary network (dCN) (31.1% ± 5.5% vs. 28.3% ± 7.2%; P < .001), whereas in the parafoveal area, VD was higher in the dCN (62.24% ± 2.8% vs. 56.5% ± 2.5%; P < .001). Flow area in the 1-mm radius circle in the sCN was less than in the dCN. Superficial foveal avascular zone (sFAZ) size was negatively correlated with the VD of the foveal sCN, but in the deep FAZ (dFAZ) was not correlated with VD or blood flow area of the fovea. There was no difference between measured VD and blood flow surface area in both eyes of the subjects. OCTA could be used as a noninvasive, repeatable, layer-free method in quantitative evaluation of VD and blood flow of macular area. The normal quantities of the vascular plexus density and flow will help in better understanding the pathophysiological basis of the vascular disease of retina. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:478-486.]. Copyright 2017, SLACK

  8. Normalization methods in time series of platelet function assays

    Science.gov (United States)

    Van Poucke, Sven; Zhang, Zhongheng; Roest, Mark; Vukicevic, Milan; Beran, Maud; Lauwereins, Bart; Zheng, Ming-Hua; Henskens, Yvonne; Lancé, Marcus; Marcus, Abraham

    2016-01-01

    Abstract Platelet function can be quantitatively assessed by specific assays such as light-transmission aggregometry, multiple-electrode aggregometry measuring the response to adenosine diphosphate (ADP), arachidonic acid, collagen, and thrombin-receptor activating peptide and viscoelastic tests such as rotational thromboelastometry (ROTEM). The task of extracting meaningful statistical and clinical information from high-dimensional data spaces in temporal multivariate clinical data represented in multivariate time series is complex. Building insightful visualizations for multivariate time series demands adequate usage of normalization techniques. In this article, various methods for data normalization (z-transformation, range transformation, proportion transformation, and interquartile range) are presented and visualized discussing the most suited approach for platelet function data series. Normalization was calculated per assay (test) for all time points and per time point for all tests. Interquartile range, range transformation, and z-transformation demonstrated the correlation as calculated by the Spearman correlation test, when normalized per assay (test) for all time points. When normalizing per time point for all tests, no correlation could be abstracted from the charts as was the case when using all data as 1 dataset for normalization. PMID:27428217

  9. Site, gender and age variation in normal skin colour on the back and the forearm: tristimulus colorimeter measurements.

    Science.gov (United States)

    Fullerton, A; Serup, J

    1997-02-01

    To study whether anatomical location and age and gender of subjects had any influence on the objective skin colour measurements. Baseline colour in prone position was measured with the Minolta ChromaMeter® in the upper, middle and lower level of the upper back and on the forearm of 168 volunteers. These two sites are commonly used in skin testing. Higher basal a* and lower basal L* levels were found on the upper scapular region compared to the lower scapular region and the subscapular region. The basal b* level showed no variation relative to site. The basal a* and the basal b* levels were lower on the forearm compared to the upper back while the basal L* level was higher. Females above 65 years showed a less coloured skin with lower values as compared to those of younger age. Females were found to have a generally lower basal a* level than males both on the upper back and forearm skin. These relatively major differences and sources of variation have to be considered when planning irritancy studies where colour differences between erythema and normal skin is used.

  10. Measurement of normalized differential t\\overline{t} cross sections in the dilepton channel from pp collisions at √{s}=13 TeV

    Science.gov (United States)

    Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Ambrogi, F.; Asilar, E.; Bergauer, T.; Brandstetter, J.; Brondolin, E.; Dragicevic, M.; Erö, J.; Flechl, M.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Grossmann, J.; Hrubec, J.; Jeitler, M.; König, A.; Krammer, N.; Krätschmer, I.; Liko, D.; Madlener, T.; Mikulec, I.; Pree, E.; Rabady, D.; Rad, N.; Rohringer, H.; Schieck, J.; Schöfbeck, R.; Spanring, M.; Spitzbart, D.; Strauss, J.; Waltenberger, W.; Wittmann, J.; Wulz, C.-E.; Zarucki, M.; Chekhovsky, V.; Mossolov, V.; Suarez Gonzalez, J.; De Wolf, E. A.; Janssen, X.; Lauwers, J.; Van De Klundert, M.; Van Haevermaet, H.; Van Mechelen, P.; Van Remortel, N.; Van Spilbeeck, A.; Abu Zeid, S.; Blekman, F.; D'Hondt, J.; De Bruyn, I.; De Clercq, J.; Deroover, K.; Flouris, G.; Lowette, S.; Moortgat, S.; Moreels, L.; Olbrechts, A.; Python, Q.; Skovpen, K.; Tavernier, S.; Van Doninck, W.; Van Mulders, P.; Van Parijs, I.; Brun, H.; Clerbaux, B.; De Lentdecker, G.; Delannoy, H.; Fasanella, G.; Favart, L.; Goldouzian, R.; Grebenyuk, A.; Karapostoli, G.; Lenzi, T.; Luetic, J.; Maerschalk, T.; Marinov, A.; Randle-conde, A.; Seva, T.; Vander Velde, C.; Vanlaer, P.; Vannerom, D.; Yonamine, R.; Zenoni, F.; Zhang, F.; Cimmino, A.; Cornelis, T.; Dobur, D.; Fagot, A.; Gul, M.; Khvastunov, I.; Poyraz, D.; Roskas, C.; Salva, S.; Tytgat, M.; Verbeke, W.; Zaganidis, N.; Bakhshiansohi, H.; Bondu, O.; Brochet, S.; Bruno, G.; Caudron, A.; De Visscher, S.; Delaere, C.; Delcourt, M.; Francois, B.; Giammanco, A.; Jafari, A.; Komm, M.; Krintiras, G.; Lemaitre, V.; Magitteri, A.; Mertens, A.; Musich, M.; Piotrzkowski, K.; Quertenmont, L.; Vidal Marono, M.; Wertz, S.; Beliy, N.; Aldá Júnior, W. L.; Alves, F. L.; Alves, G. A.; Brito, L.; Correa Martins Junior, M.; Hensel, C.; Moraes, A.; Pol, M. E.; Rebello Teles, P.; Belchior Batista Das Chagas, E.; Carvalho, W.; Chinellato, J.; Custódio, A.; Da Costa, E. M.; Da Silveira, G. G.; De Jesus Damiao, D.; Fonseca De Souza, S.; Huertas Guativa, L. M.; Malbouisson, H.; Melo De Almeida, M.; Mora Herrera, C.; Mundim, L.; Nogima, H.; Santoro, A.; Sznajder, A.; Tonelli Manganote, E. J.; Torres Da Silva De Araujo, F.; Vilela Pereira, A.; Ahuja, S.; Bernardes, C. A.; Fernandez Perez Tomei, T. R.; Gregores, E. M.; Mercadante, P. G.; Moon, C. S.; Novaes, S. F.; Padula, Sandra S.; Romero Abad, D.; Ruiz Vargas, J. C.; Aleksandrov, A.; Hadjiiska, R.; Iaydjiev, P.; Misheva, M.; Rodozov, M.; Stoykova, S.; Sultanov, G.; Vutova, M.; Dimitrov, A.; Glushkov, I.; Litov, L.; Pavlov, B.; Petkov, P.; Fang, W.; Gao, X.; Ahmad, M.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Chen, Y.; Jiang, C. H.; Leggat, D.; Liu, Z.; Romeo, F.; Shaheen, S. M.; Spiezia, A.; Tao, J.; Wang, C.; Wang, Z.; Yazgan, E.; Zhang, H.; Zhao, J.; Ban, Y.; Chen, G.; Li, Q.; Liu, S.; Mao, Y.; Qian, S. J.; Wang, D.; Xu, Z.; Avila, C.; Cabrera, A.; Chaparro Sierra, L. F.; Florez, C.; González Hernández, C. F.; Ruiz Alvarez, J. D.; Courbon, B.; Godinovic, N.; Lelas, D.; Puljak, I.; Ribeiro Cipriano, P. M.; Sculac, T.; Antunovic, Z.; Kovac, M.; Brigljevic, V.; Ferencek, D.; Kadija, K.; Mesic, B.; Susa, T.; Ather, M. W.; Attikis, A.; Mavromanolakis, G.; Mousa, J.; Nicolaou, C.; Ptochos, F.; Razis, P. A.; Rykaczewski, H.; Finger, M.; Finger, M.; Carrera Jarrin, E.; Abdelalim, A. A.; Mohammed, Y.; Salama, E.; Dewanjee, R. K.; Kadastik, M.; Perrini, L.; Raidal, M.; Tiko, A.; Veelken, C.; Eerola, P.; Pekkanen, J.; Voutilainen, M.; Härkönen, J.; Järvinen, T.; Karimäki, V.; Kinnunen, R.; Lampén, T.; Lassila-Perini, K.; Lehti, S.; Lindén, T.; Luukka, P.; Tuominen, E.; Tuominiemi, J.; Tuovinen, E.; Talvitie, J.; Tuuva, T.; Besancon, M.; Couderc, F.; Dejardin, M.; Denegri, D.; Faure, J. L.; Ferri, F.; Ganjour, S.; Ghosh, S.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Kucher, I.; Locci, E.; Machet, M.; Malcles, J.; Negro, G.; Rander, J.; Rosowsky, A.; Sahin, M. Ö.; Titov, M.; Abdulsalam, A.; Antropov, I.; Baffioni, S.; Beaudette, F.; Busson, P.; Cadamuro, L.; Charlot, C.; Davignon, O.; Granier de Cassagnac, R.; Jo, M.; Lisniak, S.; Lobanov, A.; Martin Blanco, J.; Nguyen, M.; Ochando, C.; Ortona, G.; Paganini, P.; Pigard, P.; Regnard, S.; Salerno, R.; Sauvan, J. B.; Sirois, Y.; Stahl Leiton, A. G.; Strebler, T.; Yilmaz, Y.; Zabi, A.; Zghiche, A.; Agram, J.-L.; Andrea, J.; Bloch, D.; Brom, J.-M.; Buttignol, M.; Chabert, E. C.; Chanon, N.; Collard, C.; Conte, E.; Coubez, X.; Fontaine, J.-C.; Gelé, D.; Goerlach, U.; Jansová, M.; Le Bihan, A.-C.; Van Hove, P.; Gadrat, S.; Beauceron, S.; Bernet, C.; Boudoul, G.; Chierici, R.; Contardo, D.; Depasse, P.; El Mamouni, H.; Fay, J.; Finco, L.; Gascon, S.; Gouzevitch, M.; Grenier, G.; Ille, B.; Lagarde, F.; Laktineh, I. B.; Lethuillier, M.; Mirabito, L.; Pequegnot, A. L.; Perries, S.; Popov, A.; Sordini, V.; Vander Donckt, M.; Viret, S.; Khvedelidze, A.; Tsamalaidze, Z.; Autermann, C.; Beranek, S.; Feld, L.; Kiesel, M. K.; Klein, K.; Lipinski, M.; Preuten, M.; Schomakers, C.; Schulz, J.; Verlage, T.; Albert, A.; Brodski, M.; Dietz-Laursonn, E.; Duchardt, D.; Endres, M.; Erdmann, M.; Erdweg, S.; Esch, T.; Fischer, R.; Güth, A.; Hamer, M.; Hebbeker, T.; Heidemann, C.; Hoepfner, K.; Knutzen, S.; Merschmeyer, M.; Meyer, A.; Millet, P.; Mukherjee, S.; Olschewski, M.; Padeken, K.; Pook, T.; Radziej, M.; Reithler, H.; Rieger, M.; Scheuch, F.; Teyssier, D.; Thüer, S.; Flügge, G.; Kargoll, B.; Kress, T.; Künsken, A.; Lingemann, J.; Müller, T.; Nehrkorn, A.; Nowack, A.; Pistone, C.; Pooth, O.; Stahl, A.; Aldaya Martin, M.; Arndt, T.; Asawatangtrakuldee, C.; Beernaert, K.; Behnke, O.; Behrens, U.; Bin Anuar, A. A.; Borras, K.; Botta, V.; Campbell, A.; Connor, P.; Contreras-Campana, C.; Costanza, F.; Diez Pardos, C.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Eren, E.; Gallo, E.; Garay Garcia, J.; Geiser, A.; Gizhko, A.; Grados Luyando, J. M.; Grohsjean, A.; Gunnellini, P.; Harb, A.; Hauk, J.; Hempel, M.; Jung, H.; Kalogeropoulos, A.; Kasemann, M.; Keaveney, J.; Kleinwort, C.; Korol, I.; Krücker, D.; Lange, W.; Lelek, A.; Lenz, T.; Leonard, J.; Lipka, K.; Lohmann, W.; Mankel, R.; Melzer-Pellmann, I.-A.; Meyer, A. B.; Mittag, G.; Mnich, J.; Mussgiller, A.; Ntomari, E.; Pitzl, D.; Placakyte, R.; Raspereza, A.; Roland, B.; Savitskyi, M.; Saxena, P.; Shevchenko, R.; Spannagel, S.; Stefaniuk, N.; Van Onsem, G. P.; Walsh, R.; Wen, Y.; Wichmann, K.; Wissing, C.; Zenaiev, O.; Bein, S.; Blobel, V.; Centis Vignali, M.; Draeger, A. R.; Dreyer, T.; Garutti, E.; Gonzalez, D.; Haller, J.; Hoffmann, M.; Junkes, A.; Klanner, R.; Kogler, R.; Kovalchuk, N.; Kurz, S.; Lapsien, T.; Marchesini, I.; Marconi, D.; Meyer, M.; Niedziela, M.; Nowatschin, D.; Pantaleo, F.; Peiffer, T.; Perieanu, A.; Scharf, C.; Schleper, P.; Schmidt, A.; Schumann, S.; Schwandt, J.; Sonneveld, J.; Stadie, H.; Steinbrück, G.; Stober, F. M.; Stöver, M.; Tholen, H.; Troendle, D.; Usai, E.; Vanelderen, L.; Vanhoefer, A.; Vormwald, B.; Akbiyik, M.; Barth, C.; Baur, S.; Butz, E.; Caspart, R.; Chwalek, T.; Colombo, F.; De Boer, W.; Dierlamm, A.; Freund, B.; Friese, R.; Giffels, M.; Gilbert, A.; Haitz, D.; Hartmann, F.; Heindl, S. M.; Husemann, U.; Kassel, F.; Kudella, S.; Mildner, H.; Mozer, M. U.; Müller, Th.; Plagge, M.; Quast, G.; Rabbertz, K.; Schröder, M.; Shvetsov, I.; Sieber, G.; Simonis, H. J.; Ulrich, R.; Wayand, S.; Weber, M.; Weiler, T.; Williamson, S.; Wöhrmann, C.; Wolf, R.; Anagnostou, G.; Daskalakis, G.; Geralis, T.; Giakoumopoulou, V. A.; Kyriakis, A.; Loukas, D.; Topsis-Giotis, I.; Kesisoglou, S.; Panagiotou, A.; Saoulidou, N.; Evangelou, I.; Foudas, C.; Kokkas, P.; Manthos, N.; Papadopoulos, I.; Paradas, E.; Strologas, J.; Triantis, F. A.; Csanad, M.; Filipovic, N.; Pasztor, G.; Bencze, G.; Hajdu, C.; Horvath, D.; Sikler, F.; Veszpremi, V.; Vesztergombi, G.; Zsigmond, A. J.; Beni, N.; Czellar, S.; Karancsi, J.; Makovec, A.; Molnar, J.; Szillasi, Z.; Bartók, M.; Raics, P.; Trocsanyi, Z. L.; Ujvari, B.; Choudhury, S.; Komaragiri, J. R.; Bahinipati, S.; Bhowmik, S.; Mal, P.; Mandal, K.; Nayak, A.; Sahoo, D. K.; Sahoo, N.; Swain, S. K.; Bansal, S.; Beri, S. B.; Bhatnagar, V.; Bhawandeep, U.; Chawla, R.; Dhingra, N.; Kalsi, A. K.; Kaur, A.; Kaur, M.; Kumar, R.; Kumari, P.; Mehta, A.; Mittal, M.; Singh, J. B.; Walia, G.; Kumar, Ashok; Shah, Aashaq; Bhardwaj, A.; Chauhan, S.; Choudhary, B. C.; Garg, R. B.; Keshri, S.; Kumar, A.; Malhotra, S.; Naimuddin, M.; Ranjan, K.; Sharma, R.; Sharma, V.; Bhardwaj, R.; Bhattacharya, R.; Bhattacharya, S.; Dey, S.; Dutt, S.; Dutta, S.; Ghosh, S.; Majumdar, N.; Modak, A.; Mondal, K.; Mukhopadhyay, S.; Nandan, S.; Purohit, A.; Roy, A.; Roy, D.; Roy Chowdhury, S.; Sarkar, S.; Sharan, M.; Thakur, S.; Behera, P. K.; Chudasama, R.; Dutta, D.; Jha, V.; Kumar, V.; Mohanty, A. K.; Netrakanti, P. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Dugad, S.; Mahakud, B.; Mitra, S.; Mohanty, G. B.; Parida, B.; Sur, N.; Sutar, B.; Banerjee, S.; Bhattacharya, S.; Chatterjee, S.; Das, P.; Guchait, M.; Jain, Sa.; Kumar, S.; Maity, M.; Majumder, G.; Mazumdar, K.; Sarkar, T.; Wickramage, N.; Chauhan, S.; Dube, S.; Hegde, V.; Kapoor, A.; Kothekar, K.; Pandey, S.; Rane, A.; Sharma, S.; Chenarani, S.; Eskandari Tadavani, E.; Etesami, S. M.; Khakzad, M.; Mohammadi Najafabadi, M.; Naseri, M.; Paktinat Mehdiabadi, S.; Rezaei Hosseinabadi, F.; Safarzadeh, B.; Zeinali, M.; Felcini, M.; Grunewald, M.; Abbrescia, M.; Calabria, C.; Caputo, C.; Colaleo, A.; Creanza, D.; Cristella, L.; De Filippis, N.; De Palma, M.; Errico, F.; Fiore, L.; Iaselli, G.; Maggi, G.; Maggi, M.; Miniello, G.; My, S.; Nuzzo, S.; Pompili, A.; Pugliese, G.; Radogna, R.; Ranieri, A.; Selvaggi, G.; Sharma, A.; Silvestris, L.; Venditti, R.; Verwilligen, P.; Abbiendi, G.; Battilana, C.; Bonacorsi, D.; Braibant-Giacomelli, S.; Brigliadori, L.; Campanini, R.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Chhibra, S. S.; Codispoti, G.; Cuffiani, M.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Fasanella, D.; Giacomelli, P.; Guiducci, L.; Marcellini, S.; Masetti, G.; Navarria, F. L.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Tosi, N.; Albergo, S.; Costa, S.; Di Mattia, A.; Giordano, F.; Potenza, R.; Tricomi, A.; Tuve, C.; Barbagli, G.; Chatterjee, K.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Lenzi, P.; Meschini, M.; Paoletti, S.; Russo, L.; Sguazzoni, G.; Strom, D.; Viliani, L.; Benussi, L.; Bianco, S.; Fabbri, F.; Piccolo, D.; Primavera, F.; Calvelli, V.; Ferro, F.; Robutti, E.; Tosi, S.; Brianza, L.; Brivio, F.; Ciriolo, V.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Ghezzi, A.; Govoni, P.; Malberti, M.; Malvezzi, S.; Manzoni, R. A.; Menasce, D.; Moroni, L.; Paganoni, M.; Pauwels, K.; Pedrini, D.; Pigazzini, S.; Ragazzi, S.; Tabarelli de Fatis, T.; Buontempo, S.; Cavallo, N.; Di Guida, S.; Esposito, M.; Fabozzi, F.; Fienga, F.; Iorio, A. O. M.; Khan, W. A.; Lanza, G.; Lista, L.; Meola, S.; Paolucci, P.; Sciacca, C.; Thyssen, F.; Azzi, P.; Bacchetta, N.; Benato, L.; Bisello, D.; Boletti, A.; Carlin, R.; Carvalho Antunes De Oliveira, A.; Checchia, P.; Dall'Osso, M.; De Castro Manzano, P.; Dorigo, T.; Gasparini, F.; Gasparini, U.; Gozzelino, A.; Lacaprara, S.; Margoni, M.; Meneguzzo, A. T.; Passaseo, M.; Pegoraro, M.; Pozzobon, N.; Ronchese, P.; Rossin, R.; Simonetto, F.; Torassa, E.; Zanetti, M.; Zotto, P.; Braghieri, A.; Fallavollita, F.; Magnani, A.; Montagna, P.; Ratti, S. P.; Re, V.; Ressegotti, M.; Riccardi, C.; Salvini, P.; Vai, I.; Vitulo, P.; Alunni Solestizi, L.; Bilei, G. M.; Ciangottini, D.; Fanò, L.; Lariccia, P.; Leonardi, R.; Mantovani, G.; Mariani, V.; Menichelli, M.; Saha, A.; Santocchia, A.; Spiga, D.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Bernardini, J.; Boccali, T.; Borrello, L.; Castaldi, R.; Ciocci, M. A.; Dell'Orso, R.; Fedi, G.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Martini, L.; Messineo, A.; Palla, F.; Rizzi, A.; Savoy-Navarro, A.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Barone, L.; Cavallari, F.; Cipriani, M.; Daci, N.; Del Re, D.; Diemoz, M.; Gelli, S.; Longo, E.; Margaroli, F.; Marzocchi, B.; Meridiani, P.; Organtini, G.; Paramatti, R.; Preiato, F.; Rahatlou, S.; Rovelli, C.; Santanastasio, F.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bartosik, N.; Bellan, R.; Biino, C.; Cartiglia, N.; Cenna, F.; Costa, M.; Covarelli, R.; Degano, A.; Demaria, N.; Kiani, B.; Mariotti, C.; Maselli, S.; Migliore, E.; Monaco, V.; Monteil, E.; Monteno, M.; Obertino, M. M.; Pacher, L.; Pastrone, N.; Pelliccioni, M.; Pinna Angioni, G. L.; Ravera, F.; Romero, A.; Ruspa, M.; Sacchi, R.; Shchelina, K.; Sola, V.; Solano, A.; Staiano, A.; Traczyk, P.; Belforte, S.; Casarsa, M.; Cossutti, F.; Della Ricca, G.; Zanetti, A.; Kim, D. H.; Kim, G. N.; Kim, M. S.; Lee, J.; Lee, S.; Lee, S. W.; Oh, Y. D.; Sekmen, S.; Son, D. C.; Yang, Y. C.; Lee, A.; Kim, H.; Moon, D. H.; Oh, G.; Brochero Cifuentes, J. A.; Goh, J.; Kim, T. J.; Cho, S.; Choi, S.; Go, Y.; Gyun, D.; Ha, S.; Hong, B.; Jo, Y.; Kim, Y.; Lee, K.; Lee, K. S.; Lee, S.; Lim, J.; Park, S. K.; Roh, Y.; Almond, J.; Kim, J.; Kim, J. S.; Lee, H.; Lee, K.; Nam, K.; Oh, S. B.; Radburn-Smith, B. C.; Seo, S. h.; Yang, U. K.; Yoo, H. D.; Yu, G. B.; Choi, M.; Kim, H.; Kim, J. H.; Lee, J. S. H.; Park, I. C.; Ryu, G.; Choi, Y.; Hwang, C.; Lee, J.; Yu, I.; Dudenas, V.; Juodagalvis, A.; Vaitkus, J.; Ahmed, I.; Ibrahim, Z. A.; Md Ali, M. A. B.; Mohamad Idris, F.; Wan Abdullah, W. A. T.; Yusli, M. N.; Zolkapli, Z.; Castilla-Valdez, H.; De La Cruz-Burelo, E.; Heredia-De La Cruz, I.; Lopez-Fernandez, R.; Mejia Guisao, J.; Sanchez-Hernandez, A.; Carrillo Moreno, S.; Oropeza Barrera, C.; Vazquez Valencia, F.; Pedraza, I.; Salazar Ibarguen, H. A.; Uribe Estrada, C.; Morelos Pineda, A.; Krofcheck, D.; Butler, P. H.; Ahmad, A.; Ahmad, M.; Hassan, Q.; Hoorani, H. R.; Saddique, A.; Shah, M. A.; Shoaib, M.; Waqas, M.; Bialkowska, H.; Bluj, M.; Boimska, B.; Frueboes, T.; Górski, M.; Kazana, M.; Nawrocki, K.; Romanowska-Rybinska, K.; Szleper, M.; Zalewski, P.; Bunkowski, K.; Byszuk, A.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Misiura, M.; Olszewski, M.; Pyskir, A.; Walczak, M.; Bargassa, P.; Beirão Da Cruz E Silva, C.; Calpas, B.; Di Francesco, A.; Faccioli, P.; Gallinaro, M.; Hollar, J.; Leonardo, N.; Lloret Iglesias, L.; Nemallapudi, M. V.; Seixas, J.; Toldaiev, O.; Vadruccio, D.; Varela, J.; Afanasiev, S.; Bunin, P.; Gavrilenko, M.; Golutvin, I.; Gorbunov, I.; Kamenev, A.; Karjavin, V.; Lanev, A.; Malakhov, A.; Matveev, V.; Palichik, V.; Perelygin, V.; Shmatov, S.; Shulha, S.; Skatchkov, N.; Smirnov, V.; Voytishin, N.; Zarubin, A.; Ivanov, Y.; Kim, V.; Kuznetsova, E.; Levchenko, P.; Murzin, V.; Oreshkin, V.; Smirnov, I.; Sulimov, V.; Uvarov, L.; Vavilov, S.; Vorobyev, A.; Andreev, Yu.; Dermenev, A.; Gninenko, S.; Golubev, N.; Karneyeu, A.; Kirsanov, M.; Krasnikov, N.; Pashenkov, A.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Spiridonov, A.; Stepennov, A.; Toms, M.; Vlasov, E.; Zhokin, A.; Aushev, T.; Bylinkin, A.; Danilov, M.; Parygin, P.; Tarkovskii, E.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Terkulov, A.; Baskakov, A.; Belyaev, A.; Boos, E.; Bunichev, V.; Dubinin, M.; Dudko, L.; Klyukhin, V.; Kodolova, O.; Korneeva, N.; Lokhtin, I.; Miagkov, I.; Obraztsov, S.; Perfilov, M.; Savrin, V.; Volkov, P.; Blinov, V.; Skovpen, Y.; Shtol, D.; Azhgirey, I.; Bayshev, I.; Bitioukov, S.; Elumakhov, D.; Kachanov, V.; Kalinin, A.; Konstantinov, D.; Krychkine, V.; Petrov, V.; Ryutin, R.; Sobol, A.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Adzic, P.; Cirkovic, P.; Devetak, D.; Dordevic, M.; Milosevic, J.; Rekovic, V.; Alcaraz Maestre, J.; Barrio Luna, M.; Cerrada, M.; Colino, N.; De La Cruz, B.; Delgado Peris, A.; Escalante Del Valle, A.; Fernandez Bedoya, C.; Fernández Ramos, J. P.; Flix, J.; Fouz, M. C.; Garcia-Abia, P.; Gonzalez Lopez, O.; Goy Lopez, S.; Hernandez, J. M.; Josa, M. I.; Pérez-Calero Yzquierdo, A.; Puerta Pelayo, J.; Quintario Olmeda, A.; Redondo, I.; Romero, L.; Soares, M. S.; Álvarez Fernández, A.; de Trocóniz, J. F.; Missiroli, M.; Moran, D.; Cuevas, J.; Erice, C.; Fernandez Menendez, J.; Gonzalez Caballero, I.; González Fernández, J. R.; Palencia Cortezon, E.; Sanchez Cruz, S.; Suárez Andrés, I.; Vischia, P.; Vizan Garcia, J. M.; Cabrillo, I. J.; Calderon, A.; Chazin Quero, B.; Curras, E.; Fernandez, M.; Garcia-Ferrero, J.; Gomez, G.; Lopez Virto, A.; Marco, J.; Martinez Rivero, C.; Martinez Ruiz del Arbol, P.; Matorras, F.; Piedra Gomez, J.; Rodrigo, T.; Ruiz-Jimeno, A.; Scodellaro, L.; Trevisani, N.; Vila, I.; Vilar Cortabitarte, R.; Abbaneo, D.; Auffray, E.; Baillon, P.; Ball, A. H.; Barney, D.; Bianco, M.; Bloch, P.; Bocci, A.; Botta, C.; Camporesi, T.; Castello, R.; Cepeda, M.; Cerminara, G.; Chapon, E.; Chen, Y.; d'Enterria, D.; Dabrowski, A.; Daponte, V.; David, A.; De Gruttola, M.; De Roeck, A.; Di Marco, E.; Dobson, M.; Dorney, B.; du Pree, T.; Dünser, M.; Dupont, N.; Elliott-Peisert, A.; Everaerts, P.; Franzoni, G.; Fulcher, J.; Funk, W.; Gigi, D.; Gill, K.; Glege, F.; Gulhan, D.; Gundacker, S.; Guthoff, M.; Harris, P.; Hegeman, J.; Innocente, V.; Janot, P.; Karacheban, O.; Kieseler, J.; Kirschenmann, H.; Knünz, V.; Kornmayer, A.; Kortelainen, M. J.; Krammer, M.; Lange, C.; Lecoq, P.; Lourenço, C.; Lucchini, M. T.; Malgeri, L.; Mannelli, M.; Martelli, A.; Meijers, F.; Merlin, J. A.; Mersi, S.; Meschi, E.; Milenovic, P.; Moortgat, F.; Mulders, M.; Neugebauer, H.; Orfanelli, S.; Orsini, L.; Pape, L.; Perez, E.; Peruzzi, M.; Petrilli, A.; Petrucciani, G.; Pfeiffer, A.; Pierini, M.; Racz, A.; Reis, T.; Rolandi, G.; Rovere, M.; Sakulin, H.; Schäfer, C.; Schwick, C.; Seidel, M.; Selvaggi, M.; Sharma, A.; Silva, P.; Sphicas, P.; Steggemann, J.; Stoye, M.; Tosi, M.; Treille, D.; Triossi, A.; Tsirou, A.; Veckalns, V.; Veres, G. I.; Verweij, M.; Wardle, N.; Zeuner, W. D.; Bertl, W.; Deiters, K.; Erdmann, W.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; Langenegger, U.; Rohe, T.; Wiederkehr, S. A.; Bachmair, F.; Bäni, L.; Berger, P.; Bianchini, L.; Casal, B.; Dissertori, G.; Dittmar, M.; Donegà, M.; Grab, C.; Heidegger, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Klijnsma, T.; Lustermann, W.; Mangano, B.; Marionneau, M.; Meinhard, M. T.; Meister, D.; Micheli, F.; Musella, P.; Nessi-Tedaldi, F.; Pandolfi, F.; Pata, J.; Pauss, F.; Perrin, G.; Perrozzi, L.; Quittnat, M.; Rossini, M.; Schönenberger, M.; Shchutska, L.; Starodumov, A.; Tavolaro, V. R.; Theofilatos, K.; Vesterbacka Olsson, M. L.; Wallny, R.; Zagozdzinska, A.; Zhu, D. H.; Aarrestad, T. K.; Amsler, C.; Caminada, L.; Canelli, M. F.; De Cosa, A.; Donato, S.; Galloni, C.; Hinzmann, A.; Hreus, T.; Kilminster, B.; Ngadiuba, J.; Pinna, D.; Rauco, G.; Robmann, P.; Salerno, D.; Seitz, C.; Zucchetta, A.; Candelise, V.; Doan, T. H.; Jain, Sh.; Khurana, R.; Konyushikhin, M.; Kuo, C. M.; Lin, W.; Pozdnyakov, A.; Yu, S. S.; Kumar, Arun; Chang, P.; Chao, Y.; Chen, K. F.; Chen, P. H.; Fiori, F.; Hou, W.-S.; Hsiung, Y.; Liu, Y. F.; Lu, R.-S.; Miñano Moya, M.; Paganis, E.; Psallidas, A.; Tsai, J. f.; Asavapibhop, B.; Kovitanggoon, K.; Singh, G.; Srimanobhas, N.; Adiguzel, A.; Boran, F.; Cerci, S.; Damarseckin, S.; Demiroglu, Z. S.; Dozen, C.; Dumanoglu, I.; Girgis, S.; Gokbulut, G.; Guler, Y.; Hos, I.; Kangal, E. E.; Kara, O.; Kayis Topaksu, A.; Kiminsu, U.; Oglakci, M.; Onengut, G.; Ozdemir, K.; Sunar Cerci, D.; Topakli, H.; Turkcapar, S.; Zorbakir, I. S.; Zorbilmez, C.; Bilin, B.; Karapinar, G.; Ocalan, K.; Yalvac, M.; Zeyrek, M.; Gülmez, E.; Kaya, M.; Kaya, O.; Tekten, S.; Yetkin, E. A.; Agaras, M. N.; Atay, S.; Cakir, A.; Cankocak, K.; Grynyov, B.; Levchuk, L.; Sorokin, P.; Aggleton, R.; Ball, F.; Beck, L.; Brooke, J. J.; Burns, D.; Clement, E.; Cussans, D.; Flacher, H.; Goldstein, J.; Grimes, M.; Heath, G. P.; Heath, H. F.; Jacob, J.; Kreczko, L.; Lucas, C.; Newbold, D. M.; Paramesvaran, S.; Poll, A.; Sakuma, T.; Seif El Nasr-storey, S.; Smith, D.; Smith, V. J.; Bell, K. W.; Belyaev, A.; Brew, C.; Brown, R. M.; Calligaris, L.; Cieri, D.; Cockerill, D. J. A.; Coughlan, J. A.; Harder, K.; Harper, S.; Olaiya, E.; Petyt, D.; Shepherd-Themistocleous, C. H.; Thea, A.; Tomalin, I. R.; Williams, T.; Baber, M.; Bainbridge, R.; Breeze, S.; Buchmuller, O.; Bundock, A.; Casasso, S.; Citron, M.; Colling, D.; Corpe, L.; Dauncey, P.; Davies, G.; De Wit, A.; Della Negra, M.; Di Maria, R.; Dunne, P.; Elwood, A.; Futyan, D.; Haddad, Y.; Hall, G.; Iles, G.; James, T.; Lane, R.; Laner, C.; Lyons, L.; Magnan, A.-M.; Malik, S.; Mastrolorenzo, L.; Matsushita, T.; Nash, J.; Nikitenko, A.; Pela, J.; Pesaresi, M.; Raymond, D. M.; Richards, A.; Rose, A.; Scott, E.; Seez, C.; Shtipliyski, A.; Summers, S.; Tapper, A.; Uchida, K.; Vazquez Acosta, M.; Virdee, T.; Winterbottom, D.; Wright, J.; Zenz, S. C.; Cole, J. E.; Hobson, P. R.; Khan, A.; Kyberd, P.; Reid, I. D.; Symonds, P.; Teodorescu, L.; Turner, M.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Bartek, R.; Dominguez, A.; Buccilli, A.; Cooper, S. I.; Henderson, C.; Rumerio, P.; West, C.; Arcaro, D.; Avetisyan, A.; Bose, T.; Gastler, D.; Rankin, D.; Richardson, C.; Rohlf, J.; Sulak, L.; Zou, D.; Benelli, G.; Cutts, D.; Garabedian, A.; Hakala, J.; Heintz, U.; Hogan, J. M.; Kwok, K. H. M.; Laird, E.; Landsberg, G.; Mao, Z.; Narain, M.; Pazzini, J.; Piperov, S.; Sagir, S.; Syarif, R.; Yu, D.; Band, R.; Brainerd, C.; Burns, D.; Calderon De La Barca Sanchez, M.; Chertok, M.; Conway, J.; Conway, R.; Cox, P. T.; Erbacher, R.; Flores, C.; Funk, G.; Gardner, M.; Ko, W.; Lander, R.; Mclean, C.; Mulhearn, M.; Pellett, D.; Pilot, J.; Shalhout, S.; Shi, M.; Smith, J.; Squires, M.; Stolp, D.; Tos, K.; Tripathi, M.; Wang, Z.; Bachtis, M.; Bravo, C.; Cousins, R.; Dasgupta, A.; Florent, A.; Hauser, J.; Ignatenko, M.; Mccoll, N.; Saltzberg, D.; Schnaible, C.; Valuev, V.; Bouvier, E.; Burt, K.; Clare, R.; Ellison, J.; Gary, J. W.; Ghiasi Shirazi, S. M. A.; Hanson, G.; Heilman, J.; Jandir, P.; Kennedy, E.; Lacroix, F.; Long, O. R.; Olmedo Negrete, M.; Paneva, M. I.; Shrinivas, A.; Si, W.; Wei, H.; Wimpenny, S.; Yates, B. R.; Branson, J. G.; Cerati, G. B.; Cittolin, S.; Derdzinski, M.; Gerosa, R.; Hashemi, B.; Holzner, A.; Klein, D.; Kole, G.; Krutelyov, V.; Letts, J.; Macneill, I.; Masciovecchio, M.; Olivito, D.; Padhi, S.; Pieri, M.; Sani, M.; Sharma, V.; Simon, S.; Tadel, M.; Vartak, A.; Wasserbaech, S.; Wood, J.; Würthwein, F.; Yagil, A.; Zevi Della Porta, G.; Amin, N.; Bhandari, R.; Bradmiller-Feld, J.; Campagnari, C.; Dishaw, A.; Dutta, V.; Franco Sevilla, M.; George, C.; Golf, F.; Gouskos, L.; Gran, J.; Heller, R.; Incandela, J.; Mullin, S. D.; Ovcharova, A.; Qu, H.; Richman, J.; Stuart, D.; Suarez, I.; Yoo, J.; Anderson, D.; Bendavid, J.; Bornheim, A.; Lawhorn, J. M.; Newman, H. B.; Nguyen, T.; Pena, C.; Spiropulu, M.; Vlimant, J. R.; Xie, S.; Zhang, Z.; Zhu, R. Y.; Andrews, M. B.; Ferguson, T.; Mudholkar, T.; Paulini, M.; Russ, J.; Sun, M.; Vogel, H.; Vorobiev, I.; Weinberg, M.; Cumalat, J. P.; Ford, W. T.; Jensen, F.; Johnson, A.; Krohn, M.; Leontsinis, S.; Mulholland, T.; Stenson, K.; Wagner, S. R.; Alexander, J.; Chaves, J.; Chu, J.; Dittmer, S.; Mcdermott, K.; Mirman, N.; Patterson, J. R.; Rinkevicius, A.; Ryd, A.; Skinnari, L.; Soffi, L.; Tan, S. M.; Tao, Z.; Thom, J.; Tucker, J.; Wittich, P.; Zientek, M.; Abdullin, S.; Albrow, M.; Apollinari, G.; Apresyan, A.; Apyan, A.; Banerjee, S.; Bauerdick, L. A. T.; Beretvas, A.; Berryhill, J.; Bhat, P. C.; Bolla, G.; Burkett, K.; Butler, J. N.; Canepa, A.; Cheung, H. W. K.; Chlebana, F.; Cremonesi, M.; Duarte, J.; Elvira, V. D.; Freeman, J.; Gecse, Z.; Gottschalk, E.; Gray, L.; Green, D.; Grünendahl, S.; Gutsche, O.; Harris, R. M.; Hasegawa, S.; Hirschauer, J.; Hu, Z.; Jayatilaka, B.; Jindariani, S.; Johnson, M.; Joshi, U.; Klima, B.; Kreis, B.; Lammel, S.; Lincoln, D.; Lipton, R.; Liu, M.; Liu, T.; Lopes De Sá, R.; Lykken, J.; Maeshima, K.; Magini, N.; Marraffino, J. M.; Maruyama, S.; Mason, D.; McBride, P.; Merkel, P.; Mrenna, S.; Nahn, S.; O'Dell, V.; Pedro, K.; Prokofyev, O.; Rakness, G.; Ristori, L.; Schneider, B.; Sexton-Kennedy, E.; Soha, A.; Spalding, W. J.; Spiegel, L.; Stoynev, S.; Strait, J.; Strobbe, N.; Taylor, L.; Tkaczyk, S.; Tran, N. V.; Uplegger, L.; Vaandering, E. W.; Vernieri, C.; Verzocchi, M.; Vidal, R.; Wang, M.; Weber, H. A.; Whitbeck, A.; Acosta, D.; Avery, P.; Bortignon, P.; Brinkerhoff, A.; Carnes, A.; Carver, M.; Curry, D.; Das, S.; Field, R. D.; Furic, I. K.; Konigsberg, J.; Korytov, A.; Kotov, K.; Ma, P.; Matchev, K.; Mei, H.; Mitselmakher, G.; Rank, D.; Sperka, D.; Terentyev, N.; Thomas, L.; Wang, J.; Wang, S.; Yelton, J.; Joshi, Y. R.; Linn, S.; Markowitz, P.; Martinez, G.; Rodriguez, J. L.; Ackert, A.; Adams, T.; Askew, A.; Hagopian, S.; Hagopian, V.; Johnson, K. F.; Kolberg, T.; Perry, T.; Prosper, H.; Santra, A.; Yohay, R.; Baarmand, M. M.; Bhopatkar, V.; Colafranceschi, S.; Hohlmann, M.; Noonan, D.; Roy, T.; Yumiceva, F.; Adams, M. R.; Apanasevich, L.; Berry, D.; Betts, R. R.; Cavanaugh, R.; Chen, X.; Evdokimov, O.; Gerber, C. E.; Hangal, D. A.; Hofman, D. J.; Jung, K.; Kamin, J.; Sandoval Gonzalez, I. D.; Tonjes, M. B.; Trauger, H.; Varelas, N.; Wang, H.; Wu, Z.; Zhang, J.; Bilki, B.; Clarida, W.; Dilsiz, K.; Durgut, S.; Gandrajula, R. P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Snyder, C.; Tiras, E.; Wetzel, J.; Yi, K.; Blumenfeld, B.; Cocoros, A.; Eminizer, N.; Fehling, D.; Feng, L.; Gritsan, A. V.; Maksimovic, P.; Roskes, J.; Sarica, U.; Swartz, M.; Xiao, M.; You, C.; Al-bataineh, A.; Baringer, P.; Bean, A.; Boren, S.; Bowen, J.; Castle, J.; Khalil, S.; Kropivnitskaya, A.; Majumder, D.; Mcbrayer, W.; Murray, M.; Royon, C.; Sanders, S.; Schmitz, E.; Stringer, R.; Tapia Takaki, J. D.; Wang, Q.; Ivanov, A.; Kaadze, K.; Maravin, Y.; Mohammadi, A.; Saini, L. K.; Skhirtladze, N.; Toda, S.; Rebassoo, F.; Wright, D.; Anelli, C.; Baden, A.; Baron, O.; Belloni, A.; Calvert, B.; Eno, S. C.; Ferraioli, C.; Hadley, N. J.; Jabeen, S.; Jeng, G. Y.; Kellogg, R. G.; Kunkle, J.; Mignerey, A. C.; Ricci-Tam, F.; Shin, Y. H.; Skuja, A.; Tonwar, S. C.; Abercrombie, D.; Allen, B.; Azzolini, V.; Barbieri, R.; Baty, A.; Bi, R.; Brandt, S.; Busza, W.; Cali, I. A.; D'Alfonso, M.; Demiragli, Z.; Gomez Ceballos, G.; Goncharov, M.; Hsu, D.; Iiyama, Y.; Innocenti, G. M.; Klute, M.; Kovalskyi, D.; Lai, Y. S.; Lee, Y.-J.; Levin, A.; Luckey, P. D.; Maier, B.; Marini, A. C.; Mcginn, C.; Mironov, C.; Narayanan, S.; Niu, X.; Paus, C.; Roland, C.; Roland, G.; Salfeld-Nebgen, J.; Stephans, G. S. F.; Tatar, K.; Velicanu, D.; Wang, J.; Wang, T. W.; Wyslouch, B.; Benvenuti, A. C.; Chatterjee, R. M.; Evans, A.; Hansen, P.; Kalafut, S.; Kubota, Y.; Lesko, Z.; Mans, J.; Nourbakhsh, S.; Ruckstuhl, N.; Rusack, R.; Turkewitz, J.; Acosta, J. G.; Oliveros, S.; Avdeeva, E.; Bloom, K.; Claes, D. R.; Fangmeier, C.; Gonzalez Suarez, R.; Kamalieddin, R.; Kravchenko, I.; Monroy, J.; Siado, J. E.; Snow, G. R.; Stieger, B.; Alyari, M.; Dolen, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Nguyen, D.; Parker, A.; Rappoccio, S.; Roozbahani, B.; Alverson, G.; Barberis, E.; Hortiangtham, A.; Massironi, A.; Morse, D. M.; Nash, D.; Orimoto, T.; Teixeira De Lima, R.; Trocino, D.; Wang, R.-J.; Wood, D.; Bhattacharya, S.; Charaf, O.; Hahn, K. A.; Mucia, N.; Odell, N.; Pollack, B.; Schmitt, M. H.; Sung, K.; Trovato, M.; Velasco, M.; Dev, N.; Hildreth, M.; Hurtado Anampa, K.; Jessop, C.; Karmgard, D. J.; Kellams, N.; Lannon, K.; Loukas, N.; Marinelli, N.; Meng, F.; Mueller, C.; Musienko, Y.; Planer, M.; Reinsvold, A.; Ruchti, R.; Smith, G.; Taroni, S.; Wayne, M.; Wolf, M.; Woodard, A.; Alimena, J.; Antonelli, L.; Bylsma, B.; Durkin, L. S.; Flowers, S.; Francis, B.; Hart, A.; Hill, C.; Ji, W.; Liu, B.; Luo, W.; Puigh, D.; Winer, B. L.; Wulsin, H. W.; Benaglia, A.; Cooperstein, S.; Driga, O.; Elmer, P.; Hardenbrook, J.; Hebda, P.; Lange, D.; Luo, J.; Marlow, D.; Mei, K.; Ojalvo, I.; Olsen, J.; Palmer, C.; Piroué, P.; Stickland, D.; Svyatkovskiy, A.; Tully, C.; Malik, S.; Norberg, S.; Barker, A.; Barnes, V. E.; Folgueras, S.; Gutay, L.; Jha, M. K.; Jones, M.; Jung, A. W.; Khatiwada, A.; Miller, D. H.; Neumeister, N.; Schulte, J. F.; Sun, J.; Wang, F.; Xie, W.; Cheng, T.; Parashar, N.; Stupak, J.; Adair, A.; Akgun, B.; Chen, Z.; Ecklund, K. M.; Geurts, F. J. M.; Guilbaud, M.; Li, W.; Michlin, B.; Northup, M.; Padley, B. P.; Roberts, J.; Rorie, J.; Tu, Z.; Zabel, J.; Bodek, A.; de Barbaro, P.; Demina, R.; Duh, Y. t.; Ferbel, T.; Galanti, M.; Garcia-Bellido, A.; Han, J.; Hindrichs, O.; Khukhunaishvili, A.; Lo, K. H.; Tan, P.; Verzetti, M.; Ciesielski, R.; Goulianos, K.; Mesropian, C.; Agapitos, A.; Chou, J. P.; Gershtein, Y.; Gómez Espinosa, T. A.; Halkiadakis, E.; Heindl, M.; Hughes, E.; Kaplan, S.; Kunnawalkam Elayavalli, R.; Kyriacou, S.; Lath, A.; Montalvo, R.; Nash, K.; Osherson, M.; Saka, H.; Salur, S.; Schnetzer, S.; Sheffield, D.; Somalwar, S.; Stone, R.; Thomas, S.; Thomassen, P.; Walker, M.; Foerster, M.; Heideman, J.; Riley, G.; Rose, K.; Spanier, S.; Thapa, K.; Bouhali, O.; Castaneda Hernandez, A.; Celik, A.; Dalchenko, M.; De Mattia, M.; Delgado, A.; Dildick, S.; Eusebi, R.; Gilmore, J.; Huang, T.; Kamon, T.; Mueller, R.; Pakhotin, Y.; Patel, R.; Perloff, A.; Perniè, L.; Rathjens, D.; Safonov, A.; Tatarinov, A.; Ulmer, K. A.; Akchurin, N.; Damgov, J.; De Guio, F.; Dudero, P. R.; Faulkner, J.; Gurpinar, E.; Kunori, S.; Lamichhane, K.; Lee, S. W.; Libeiro, T.; Peltola, T.; Undleeb, S.; Volobouev, I.; Wang, Z.; Greene, S.; Gurrola, A.; Janjam, R.; Johns, W.; Maguire, C.; Melo, A.; Ni, H.; Sheldon, P.; Tuo, S.; Velkovska, J.; Xu, Q.; Arenton, M. W.; Barria, P.; Cox, B.; Hirosky, R.; Ledovskoy, A.; Li, H.; Neu, C.; Sinthuprasith, T.; Sun, X.; Wang, Y.; Wolfe, E.; Xia, F.; Clarke, C.; Harr, R.; Karchin, P. E.; Sturdy, J.; Zaleski, S.; Buchanan, J.; Caillol, C.; Dasu, S.; Dodd, L.; Duric, S.; Gomber, B.; Grothe, M.; Herndon, M.; Hervé, A.; Hussain, U.; Klabbers, P.; Lanaro, A.; Levine, A.; Long, K.; Loveless, R.; Pierro, G. A.; Polese, G.; Ruggles, T.; Savin, A.; Smith, N.; Smith, W. H.; Taylor, D.; Woods, N.

    2018-04-01

    Normalized differential cross sections for top quark pair production are measured in the dilepton (e+e-, μ + μ -, and μ ∓e±) decay channels in proton-proton collisions at a center-of-mass energy of 13 TeV. The measurements are performed with data corresponding to an integrated luminosity of 2.1 fb-1 using the CMS detector at the LHC. The cross sections are measured differentially as a function of the kinematic properties of the leptons, jets from bottom quark hadronization, top quarks, and top quark pairs at the particle and parton levels. The results are compared to several Monte Carlo generators that implement calculations up to next-to-leading order in perturbative quantum chromodynamics interfaced with parton showering, and also to fixed-order theoretical calculations of top quark pair production up to next-to-next-to-leading order. [Figure not available: see fulltext.

  11. powerbox: Arbitrarily structured, arbitrary-dimension boxes and log-normal mocks

    Science.gov (United States)

    Murray, Steven G.

    2018-05-01

    powerbox creates density grids (or boxes) with an arbitrary two-point distribution (i.e. power spectrum). The software works in any number of dimensions, creates Gaussian or Log-Normal fields, and measures power spectra of output fields to ensure consistency. The primary motivation for creating the code was the simple creation of log-normal mock galaxy distributions, but the methodology can be used for other applications.

  12. Regional ADC values of the normal brain: differences due to age, gender, and laterality.

    Science.gov (United States)

    Naganawa, Shinji; Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo; Ishigaki, Takeo

    2003-01-01

    The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean+/-standard deviation 2.3+/-1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (pright frontal, bilateral thalamus, and temporal (pbrain and may be useful for the future quantitative study as a reference.

  13. Longitudinal study of serum placental GH in 455 normal pregnancies

    DEFF Research Database (Denmark)

    Chellakooty, Marla; Skibsted, Lillian; Skouby, Sven O

    2002-01-01

    women with normal singleton pregnancies at approximately 19 and 28 wk gestation. Serum placental GH concentrations were measured by a highly specific immunoradiometric assay, and fetal size was measured by ultrasound. Data on birth weight, gender, prepregnancy body mass index (BMI), parity, and smoking...

  14. Measurement of blowdown flow rates using load cells

    International Nuclear Information System (INIS)

    Dolas, P.K.; Venkat Raj, V.; Ghosh, A.K.; Murty, L.G.K.; Muralidhar Rao, S.

    1980-01-01

    To establish a reliable method for measuring two-phase flow, experiments were planned for measurement of transient single phase flow rates from vessels using load cells. Suitability of lead-zirconate-titanate piezoelectric ceramic discs was examined. Discharge time constant of the disc used was low, leading to large measurement errors. Subsequently, experiments were carried out using strain gauge load cells and these were found satisfactory. The unsteady flow equation has been derived for the system under investigation. The equation has been solved numerically using the fourth order Runge-Kutta method and also by integrating it analytically. The experimental results are compared with the theoretical results and presented in this report. (auth.)

  15. Improving the dictionary lookup approach for disease normalization using enhanced dictionary and query expansion

    Science.gov (United States)

    Jonnagaddala, Jitendra; Jue, Toni Rose; Chang, Nai-Wen; Dai, Hong-Jie

    2016-01-01

    The rapidly increasing biomedical literature calls for the need of an automatic approach in the recognition and normalization of disease mentions in order to increase the precision and effectivity of disease based information retrieval. A variety of methods have been proposed to deal with the problem of disease named entity recognition and normalization. Among all the proposed methods, conditional random fields (CRFs) and dictionary lookup method are widely used for named entity recognition and normalization respectively. We herein developed a CRF-based model to allow automated recognition of disease mentions, and studied the effect of various techniques in improving the normalization results based on the dictionary lookup approach. The dataset from the BioCreative V CDR track was used to report the performance of the developed normalization methods and compare with other existing dictionary lookup based normalization methods. The best configuration achieved an F-measure of 0.77 for the disease normalization, which outperformed the best dictionary lookup based baseline method studied in this work by an F-measure of 0.13. Database URL: https://github.com/TCRNBioinformatics/DiseaseExtract PMID:27504009

  16. Exponential model normalization for electrical capacitance tomography with external electrodes under gap permittivity conditions

    International Nuclear Information System (INIS)

    Baidillah, Marlin R; Takei, Masahiro

    2017-01-01

    A nonlinear normalization model which is called exponential model for electrical capacitance tomography (ECT) with external electrodes under gap permittivity conditions has been developed. The exponential model normalization is proposed based on the inherently nonlinear relationship characteristic between the mixture permittivity and the measured capacitance due to the gap permittivity of inner wall. The parameters of exponential equation are derived by using an exponential fitting curve based on the simulation and a scaling function is added to adjust the experiment system condition. The exponential model normalization was applied to two dimensional low and high contrast dielectric distribution phantoms by using simulation and experimental studies. The proposed normalization model has been compared with other normalization models i.e. Parallel, Series, Maxwell and Böttcher models. Based on the comparison of image reconstruction results, the exponential model is reliable to predict the nonlinear normalization of measured capacitance in term of low and high contrast dielectric distribution. (paper)

  17. Physical activity patterns in morbidly obese and normal-weight women.

    Science.gov (United States)

    Kwon, Soyang; Mohammad, Jamal; Samuel, Isaac

    2011-01-01

    To compare physical activity patterns between morbidly obese and normal-weight women. Daily physical activity of 18 morbidly obese and 7 normal-weight women aged 30-58 years was measured for 2 days using the Intelligent Device for Energy Expenditure and Activity (IDEEA) device. The obese group spent about 2 hr/day less standing and 30 min/day less walking than did the normal-weight group. Time spent standing (standing time) was positively associated with time spent walking (walking time). Age- and walking time-adjusted standing time did not differ according to weight status. Promoting standing may be a strategy to increase walking.

  18. Length and volume of morphologically normal kidneys in Korean Children: Ultrasound measurement and estimation using body size

    International Nuclear Information System (INIS)

    Kim, Jun Hwee; Kim, Myung Joon; Lim, Sok Hwan; Lee, Mi Jung; Kim, Ji Eun

    2013-01-01

    To evaluate the relationship between anthropometric measurements and renal length and volume measured with ultrasound in Korean children who have morphologically normal kidneys, and to create simple equations to estimate the renal sizes using the anthropometric measurements. We examined 794 Korean children under 18 years of age including a total of 394 boys and 400 girls without renal problems. The maximum renal length (L) (cm), orthogonal anterior-posterior diameter (D) (cm) and width (W) (cm) of each kidney were measured on ultrasound. Kidney volume was calculated as 0.523 x L x D x W (cm 3 ). Anthropometric indices including height (cm), weight (kg) and body mass index (m 2 /kg) were collected through a medical record review. We used linear regression analysis to create simple equations to estimate the renal length and the volume with those anthropometric indices that were mostly correlated with the US-measured renal sizes. Renal length showed the strongest significant correlation with patient height (R2, 0.874 and 0.875 for the right and left kidneys, respectively, p < 0.001). Renal volume showed the strongest significant correlation with patient weight (R2, 0.842 and 0.854 for the right and left kidneys, respectively, p < 0.001). The following equations were developed to describe these relationships with an estimated 95% range of renal length and volume (R2, 0.826-0.884, p < 0.001): renal length = 2.383 + 0.045 x Height (± 1.135) and = 2.374 + 0.047 x Height (± 1.173) for the right and left kidneys, respectively; and renal volume 7.941 + 1.246 x Weight (± 15.920) and = 7.303 + 1.532 x Weight (± 18.704) for the right and left kidneys, respectively. Scatter plots between height and renal length and between weight and renal volume have been established from Korean children and simple equations between them have been developed for use in clinical practice.

  19. Length and volume of morphologically normal kidneys in Korean Children: Ultrasound measurement and estimation using body size

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Hwee; Kim, Myung Joon; Lim, Sok Hwan; Lee, Mi Jung [Dept. of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Ji Eun [Biostatistics Collaboration Unit, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2013-08-15

    To evaluate the relationship between anthropometric measurements and renal length and volume measured with ultrasound in Korean children who have morphologically normal kidneys, and to create simple equations to estimate the renal sizes using the anthropometric measurements. We examined 794 Korean children under 18 years of age including a total of 394 boys and 400 girls without renal problems. The maximum renal length (L) (cm), orthogonal anterior-posterior diameter (D) (cm) and width (W) (cm) of each kidney were measured on ultrasound. Kidney volume was calculated as 0.523 x L x D x W (cm{sup 3}). Anthropometric indices including height (cm), weight (kg) and body mass index (m{sup 2}/kg) were collected through a medical record review. We used linear regression analysis to create simple equations to estimate the renal length and the volume with those anthropometric indices that were mostly correlated with the US-measured renal sizes. Renal length showed the strongest significant correlation with patient height (R2, 0.874 and 0.875 for the right and left kidneys, respectively, p < 0.001). Renal volume showed the strongest significant correlation with patient weight (R2, 0.842 and 0.854 for the right and left kidneys, respectively, p < 0.001). The following equations were developed to describe these relationships with an estimated 95% range of renal length and volume (R2, 0.826-0.884, p < 0.001): renal length = 2.383 + 0.045 x Height (± 1.135) and = 2.374 + 0.047 x Height (± 1.173) for the right and left kidneys, respectively; and renal volume 7.941 + 1.246 x Weight (± 15.920) and = 7.303 + 1.532 x Weight (± 18.704) for the right and left kidneys, respectively. Scatter plots between height and renal length and between weight and renal volume have been established from Korean children and simple equations between them have been developed for use in clinical practice.

  20. Normal Conducting RF Cavity for MICE

    International Nuclear Information System (INIS)

    Li, D.; DeMello, A.; Virostek, S.; Zisman, M.; Summers, D.

    2010-01-01

    Normal conducting RF cavities must be used for the cooling section of the international Muon Ionization Cooling Experiment (MICE), currently under construction at Rutherford Appleton Laboratory (RAL) in the UK. Eight 201-MHz cavities are needed for the MICE cooling section; fabrication of the first five cavities is complete. We report the cavity fabrication status including cavity design, fabrication techniques and preliminary low power RF measurements.

  1. Maturation of Speech and Language Functional Neuroanatomy in Pediatric Normal Controls

    Science.gov (United States)

    Devous, Michael D., Sr.; Altuna, Dianne; Furl, Nicholas, Cooper, William; Gabbert, Gretchen; Ngai, Wei Tat; Chiu, Stephanie; Scott, Jack M., III; Harris, Thomas S.; Payne, J. Kelly; Tobey, Emily A.

    2006-01-01

    Purpose: This study explores the relationship between age and resting-state regional cerebral blood flow (rCBF) in regions associated with higher order language skills using a population of normal children, adolescents, and young adults. Method: rCBF was measured in 33 normal participants between the ages of 7 and 19 years using single photon…

  2. The results of Scarf osteotomy combined with distal soft tissue procedure are mostly satisfactory in surgical management of moderate to severe hallux valgus.

    Science.gov (United States)

    Şaylı, Uğur; Akman, Budak; Tanrıöver, Altuğ; Kaspar, Çiğdem; Güven, Melih; Özler, Turhan

    2017-05-29

    Intrinsically stable diaphyseal osteotomy gained popularity in recent years for symptomatic hallux valgus deformities. In this study, Scarf osteotomy results, in surgical management of moderate to severe hallux valgus, are presented. Study group consisted of 40 feet of 32 (28 females, four males) patients surgically managed by Scarf osteotomy between September 2009 and 2011, with a mean age of 52,98 (range, 31-75) years at the time of surgery. Patient satisfaction and VAS were used for subjective evaluation while for objective measures AOFAS score, first metatarsophalangeal joint ROM and radiological measurements (intermetatarsal, hallux valgus and distal metatarsal articular angles) were evaluated. Mean follow-up period was 38 (range, 24-60) months. Sixteen feet (40%) were reported as very satisfied, 19 (47,5%) as satisfied and the remaining five (12,5%) as unsatisfied resulting with a total of 35 (87,5%) satisfaction. The mean preoperative VAS and AOFAS forefoot scores improved from 8,13±0,791 to 2,68±1,228 (p=0,0001) and from 58,25±6,15 to 78,25±8,13 (p=0,0001) on the final follow-up, respectively. The postoperative change of first metatarsophalangeal joint ROM was not statistically significant (p=0,281). On the radiological evaluation; intermetatarsal and hallux valgus angles improved from a mean value of 14,77±1,76 to 8,13±1,52° (p=0,0001) and from 35,28±5,86 to 20,10±5,55° (p=0,0001), respectively. Distal metatarsal articular angle did not show any statistically significant change (p=0,195). Scarf osteotomy combined with distal soft tissue procedure is a technically demanding procedure. The osteotomy is intrinsically stable and the correction power is high and the results are mostly satisfactory. Copyright © 2017. Published by Elsevier Ltd.

  3. Measurements of neutron and gamma ray streaming through a duct, (2), (3)

    International Nuclear Information System (INIS)

    Hashikura, Hiroyuki; Fukumoto, Hideshi; Akiyama, Masatsugu; Oka, Yoshiaki; An, Shigehiro

    1982-03-01

    Measurements of neutron and gamma ray streaming through a duct measurements of and a cavity in concrete shields were measured in the fast neutron source reactor YAYOI of the University of Tokyo. The neutron spectra measured by a NE213 scintillator and proton recoil counters were compared with the calculations using Monte Carlo code, MORSE-CG. The agreements between the experiments and the calculations were generally satisfactory. The attenuations of neutron and gamma ray in the cavity and the duct were studied in the three experimental configurations. (author)

  4. Fitting and verification of frequency modulation systems on children with normal hearing.

    Science.gov (United States)

    Schafer, Erin C; Bryant, Danielle; Sanders, Katie; Baldus, Nicole; Algier, Katherine; Lewis, Audrey; Traber, Jordan; Layden, Paige; Amin, Aneeqa

    2014-06-01

    Several recent investigations support the use of frequency modulation (FM) systems in children with normal hearing and auditory processing or listening disorders such as those diagnosed with auditory processing disorders, autism spectrum disorders, attention-deficit hyperactivity disorder, Friedreich ataxia, and dyslexia. The American Academy of Audiology (AAA) published suggested procedures, but these guidelines do not cite research evidence to support the validity of the recommended procedures for fitting and verifying nonoccluding open-ear FM systems on children with normal hearing. Documenting the validity of these fitting procedures is critical to maximize the potential FM-system benefit in the above-mentioned populations of children with normal hearing and those with auditory-listening problems. The primary goal of this investigation was to determine the validity of the AAA real-ear approach to fitting FM systems on children with normal hearing. The secondary goal of this study was to examine speech-recognition performance in noise and loudness ratings without and with FM systems in children with normal hearing sensitivity. A two-group, cross-sectional design was used in the present study. Twenty-six typically functioning children, ages 5-12 yr, with normal hearing sensitivity participated in the study. Participants used a nonoccluding open-ear FM receiver during laboratory-based testing. Participants completed three laboratory tests: (1) real-ear measures, (2) speech recognition performance in noise, and (3) loudness ratings. Four real-ear measures were conducted to (1) verify that measured output met prescribed-gain targets across the 1000-4000 Hz frequency range for speech stimuli, (2) confirm that the FM-receiver volume did not exceed predicted uncomfortable loudness levels, and (3 and 4) measure changes to the real-ear unaided response when placing the FM receiver in the child's ear. After completion of the fitting, speech recognition in noise at a -5

  5. The quantitative measurements of foveal avascular zone using optical coherence tomography angiography in normal volunteers.

    Science.gov (United States)

    Ghassemi, Fariba; Mirshahi, Reza; Bazvand, Fatemeh; Fadakar, Kaveh; Faghihi, Houshang; Sabour, Siamak

    2017-12-01

    To provide normative data of foveal avascular zone (FAZ) and thickness. In this cross-sectional study both eyes of each normal subject were scanned with optical coherence tomography angiography (OCTA) for foveal superficial and deep avascular zone (FAZ) and central foveal thickness (CFT) and parafoveal thickness (PFT). Out of a total of 224 eyes of 112 volunteers with a mean age of 37.03 (12-67) years, the mean superficial FAZ area was 0.27 mm 2 , and deep FAZ area was 0.35 mm 2 ( P  < 0.001), with no difference between both eyes. Females had a larger superficial (0.32 ± 0.11 mm 2 versus 0.23 ± 0.09 mm 2 ) and deep FAZ (0.40 ± 0.14 mm 2 versus 0.31 ± 0.10 mm 2 ) ( P  < 0.001) than males. By multivariate linear regression analysis, in normal eyes, superficial FAZ area varied significantly with the gender, CFT, and deep FAZ. Deep FAZ varied with the gender and CFT. The gender and CFT influence the size of normal superficial and deep FAZ of capillary network.

  6. SSYST, a code-system for analysing transient LWR fuel rod behaviour under off-normal conditions

    International Nuclear Information System (INIS)

    Borgwaldt, H.; Gulden, W.

    1983-01-01

    SSYST is a code-system for analysing transient fuel rod behaviour under off-normal conditions, developed conjointly by the Institut fuer Kernenergetik und Energiesysteme (IKE), Stuttgart, and Kernforschungszentrum Karlsruhe (KfK) under contract of Projek Nukleare Sicherheit (PNS) at KfK. The main differences between SSYST and similar codes are (1) an open-ended modular code organisation, and (2) a preference for simple models, wherever possible. While the first feature makes SSYST a very flexible tool, easily adapted to changing requirements, the second feature leads to short execution times. The analysis of transient rod behaviour under LOCA boundary conditions takes 2 min cpu-time (IBM-3033), so that extensive parametric studies become possible. This paper gives an outline of the overall code organisation and a general overview of the physical models implemented. Besides explaining the routine application of SSYST in the analysis of loss-of-coolant accidents, examples are given of special applications which have led to a satisfactory understanding of the decisive influence of deviations from rotational symmetry on the fuel rod perimeter. (author)

  7. SSYST: A code-system for analyzing transient LWR fuel rod behaviour under off-normal conditions

    International Nuclear Information System (INIS)

    Borgwaldt, H.; Gulden, W.

    1983-01-01

    SSYST is a code-system for analyzing transient fuel rod behaviour under off-normal conditions, developed conjointly by the Institut fur Kernenergetik und Energiesysteme (IKE), Stuttgart, and Kernforschungszentrum Karlsruhe (KfK) under contract of Projekt Nukleare Sicherheit (PNS) at KfK. The main differences between SSYST and similar codes are an open-ended modular code organization, and a preference for simple models, wherever possible. While the first feature makes SSYST a very flexible tool, easily adapted to changing requirements, the second feature leads to short execution times. The analysis of transient rod behaviour under LOCA boundary conditions takes 2 min cpu-time (IBM-3033), so that extensive parametric studies become possible. This paper gives an outline of the overall code organisation and a general overview of the physical models implemented. Besides explaining the routine application of SSYST in the analysis of loss-of-coolant accidents, examples are given of special applications which have led to a satisfactory understanding of the decisive influence of deviations from rotational symmetry on the fuel rod perimeter

  8. Quaternion normalization in additive EKF for spacecraft attitude determination. [Extended Kalman Filters

    Science.gov (United States)

    Bar-Itzhack, I. Y.; Deutschmann, J.; Markley, F. L.

    1991-01-01

    This work introduces, examines and compares several quaternion normalization algorithms, which are shown to be an effective stage in the application of the additive extended Kalman filter to spacecraft attitude determination, which is based on vector measurements. Three new normalization schemes are introduced. They are compared with one another and with the known brute force normalization scheme, and their efficiency is examined. Simulated satellite data are used to demonstate the performance of all four schemes.

  9. Displacement measurement system for linear array detector

    International Nuclear Information System (INIS)

    Zhang Pengchong; Chen Ziyu; Shen Ji

    2011-01-01

    It presents a set of linear displacement measurement system based on encoder. The system includes displacement encoders, optical lens and read out circuit. Displacement read out unit includes linear CCD and its drive circuit, two amplifier circuits, second order Butterworth low-pass filter and the binarization circuit. The coding way is introduced, and various parts of the experimental signal waveforms are given, and finally a linear experimental test results are given. The experimental results are satisfactory. (authors)

  10. Correspondence normalized ghost imaging on compressive sensing

    International Nuclear Information System (INIS)

    Zhao Sheng-Mei; Zhuang Peng

    2014-01-01

    Ghost imaging (GI) offers great potential with respect to conventional imaging techniques. It is an open problem in GI systems that a long acquisition time is be required for reconstructing images with good visibility and signal-to-noise ratios (SNRs). In this paper, we propose a new scheme to get good performance with a shorter construction time. We call it correspondence normalized ghost imaging based on compressive sensing (CCNGI). In the scheme, we enhance the signal-to-noise performance by normalizing the reference beam intensity to eliminate the noise caused by laser power fluctuations, and reduce the reconstruction time by using both compressive sensing (CS) and time-correspondence imaging (CI) techniques. It is shown that the qualities of the images have been improved and the reconstruction time has been reduced using CCNGI scheme. For the two-grayscale ''double-slit'' image, the mean square error (MSE) by GI and the normalized GI (NGI) schemes with the measurement number of 5000 are 0.237 and 0.164, respectively, and that is 0.021 by CCNGI scheme with 2500 measurements. For the eight-grayscale ''lena'' object, the peak signal-to-noise rates (PSNRs) are 10.506 and 13.098, respectively using GI and NGI schemes while the value turns to 16.198 using CCNGI scheme. The results also show that a high-fidelity GI reconstruction has been achieved using only 44% of the number of measurements corresponding to the Nyquist limit for the two-grayscale “double-slit'' object. The qualities of the reconstructed images using CCNGI are almost the same as those from GI via sparsity constraints (GISC) with a shorter reconstruction time. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  11. Selective Sensing of Gas Mixture via a Temperature Modulation Approach: New Strategy for Potentiometric Gas Sensor Obtaining Satisfactory Discriminating Features.

    Science.gov (United States)

    Li, Fu-An; Jin, Han; Wang, Jinxia; Zou, Jie; Jian, Jiawen

    2017-03-12

    A new strategy to discriminate four types of hazardous gases is proposed in this research. Through modulating the operating temperature and the processing response signal with a pattern recognition algorithm, a gas sensor consisting of a single sensing electrode, i.e., ZnO/In₂O₃ composite, is designed to differentiate NO₂, NH₃, C₃H₆, CO within the level of 50-400 ppm. Results indicate that with adding 15 wt.% ZnO to In₂O₃, the sensor fabricated at 900 °C shows optimal sensing characteristics in detecting all the studied gases. Moreover, with the aid of the principle component analysis (PCA) algorithm, the sensor operating in the temperature modulation mode demonstrates acceptable discrimination features. The satisfactory discrimination features disclose the future that it is possible to differentiate gas mixture efficiently through operating a single electrode sensor at temperature modulation mode.

  12. Normal-range verbal-declarative memory in schizophrenia.

    Science.gov (United States)

    Heinrichs, R Walter; Parlar, Melissa; Pinnock, Farena

    2017-10-01

    Cognitive impairment is prevalent and related to functional outcome in schizophrenia, but a significant minority of the patient population overlaps with healthy controls on many performance measures, including declarative-verbal-memory tasks. In this study, we assessed the validity, clinical, and functional implications of normal-range (NR), verbal-declarative memory in schizophrenia. Performance normality was defined using normative data for 8 basic California Verbal Learning Test (CVLT-II; Delis, Kramer, Kaplan, & Ober, 2000) recall and recognition trials. Schizophrenia patients (n = 155) and healthy control participants (n = 74) were assessed for performance normality, defined as scores within 1 SD of the normative mean on all 8 trials, and assigned to normal- and below-NR memory groups. NR schizophrenia patients (n = 26) and control participants (n = 51) did not differ in general verbal ability, on a reading-based estimate of premorbid ability, across all 8 CVLT-II-score comparisons or in terms of intrusion and false-positive errors and auditory working memory. NR memory patients did not differ from memory-impaired patients (n = 129) in symptom severity, and both patient groups were significantly and similarly disabled in terms of functional status in the community. These results confirm a subpopulation of schizophrenia patients with normal, verbal-declarative-memory performance and no evidence of decline from higher premorbid ability levels. However, NR patients did not experience less severe psychopathology, nor did they show advantage in community adjustment relative to impaired patients. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  13. Risk-based planning and optimization of flood management measures in developing countries : Case Pakistan

    NARCIS (Netherlands)

    Tariq, M.A.U.R.

    2011-01-01

    About 95-97% of all deaths and a significant part of the economic losses caused by floods occur in developing countries. Despite the resources spent on different measures, flood management arrangements in developing countries are still unable to deliver satisfactory results. The objective of this

  14. A comparison of vowel normalization procedures for language variation research

    Science.gov (United States)

    Adank, Patti; Smits, Roel; van Hout, Roeland

    2004-11-01

    An evaluation of vowel normalization procedures for the purpose of studying language variation is presented. The procedures were compared on how effectively they (a) preserve phonemic information, (b) preserve information about the talker's regional background (or sociolinguistic information), and (c) minimize anatomical/physiological variation in acoustic representations of vowels. Recordings were made for 80 female talkers and 80 male talkers of Dutch. These talkers were stratified according to their gender and regional background. The normalization procedures were applied to measurements of the fundamental frequency and the first three formant frequencies for a large set of vowel tokens. The normalization procedures were evaluated through statistical pattern analysis. The results show that normalization procedures that use information across multiple vowels (``vowel-extrinsic'' information) to normalize a single vowel token performed better than those that include only information contained in the vowel token itself (``vowel-intrinsic'' information). Furthermore, the results show that normalization procedures that operate on individual formants performed better than those that use information across multiple formants (e.g., ``formant-extrinsic'' F2-F1). .

  15. Arthroscopic treatment for intratendinous rotator cuff tear results in satisfactory clinical outcomes and structural integrity.

    Science.gov (United States)

    Cheon, Sang Jin; Lee, Hyo Yeol; Jeon, Woong Ki

    2018-04-20

    This study aimed to evaluate the clinical outcomes and structural integrity of arthroscopic repair of intratendinous rotator cuff tear. Patients who were diagnosed with an intratendinous tear but in whom conservative treatment failed were selected and underwent arthroscopic repair. Between 2008 and 2014, a total of 30 patients (6 men, 24 women; mean age, 59 ± 3.7 years) met the inclusion criteria and were followed up. The mean follow-up period was 26.3 ± 0.7 months. The results were evaluated using the University of California at Los Angeles (UCLA) score, the Society of the American Shoulder and Elbow Surgeons rating scale (ASES) questionnaire, and the visual analog scale (VAS) and range of motion (ROM) were measured preoperatively and at final follow-up. Magnetic resonance imaging (MRI) was performed preoperatively and at 6.7 ± 0.2 months postoperatively. Postoperative MRI was performed on 27 out of 30 patients and analysed using the Sugaya classification. Corresponding to the preoperative MRI findings, arthroscopic findings of intratendinous tears were observed in all 30 patients. The mean active forward elevation ROM was 137.3° ± 15.4° before surgery and 168.8° ± 15.2° at the final follow-up. The internal and external rotations at abduction were 31.7° ± 5.1° and 63.0° ± 11.6° before surgery, respectively, and 60.5° ± 8.0° and 75.2° ± 10.8° after surgery, respectively. The UCLA score improved from of 20.1 ± 7.4 points preoperative to 28.4 ± 5.5 points at the final follow-up. The ASES score improved from 55.7 ± 15.3 points preoperative to 82.6 ± 9.7 points postoperatively. The VAS for pain score decreased from 6.4 ± 1.2 points preoperative to 1.6 ± 0.9 points postoperative. Satisfactory outcomes (excellent/good) in terms of UCLA and ASES scores were observed in 29 of 30 patients. Based on Sugaya classification, grades I, II, and III structural integrities were observed in 9

  16. Normal cardiac diameters in cine-MRI of the heart

    International Nuclear Information System (INIS)

    Hergan, K.; Schuster, A.; Mair, M.; Burger, R.; Toepker, M.

    2004-01-01

    Purpose: To measure the normal diameters of cardiac cavities in standard cardiac views using cine MRI. Materials and Methods: Fifty-six volunteers were examined (27 male, 29 female) on a 1.5 T MR unit with ECG-triggered single shot free precision (SSFP) cine MR sequences and parallel image acquisition. Standardized echocardiographic planes were used to depict the heart of all volunteers (short axis, 4-chamber view, left and right 2-chamber views). The different diameters of the cardiac cavities were measured using a fixed protocol. Results: For the estimation of ventricular dilatation, the important female/male cross diameters of the left ventricle are 45.2±3.4/51.6±4.6 mm diastolic and 30.5±3.5/33.8±3.6 mm systolic, and of the right ventricle 30.7±3.8/37.1±5.9 mm diastolic and 22.3±3.8/28.1±4.4 mm systolic. For the determination of a left ventricular hypertrophy, relevant septal wall thickness measured in the short axis of the left ventricle of female/male volunteers are 8.0±1.0/9.9±1.2 mm diastolic and 10.9±1.4/13.6±1.9 mm systolic. The measured normal values of male volunteers were generally higher than those of female volunteers. The thickness of the ventricular septum correlated well when measured in the short axis and 4-chamber view. When measured in the 4-chamber view, the longitudinal diameter of the ventricles had a higher value in diastole and a lower value in systole, compared to the 2-chamber views of the right and left cardiac cavities. The atrial longitudinal diameters were higher in the 4-chamber view compared to the 2-chamber views, without any difference in systole or diastole. Conclusion: Diameters of cardiac cavities are easily and quickly measured. Using the tables with the normal values published here, it is simple to estimate an abnormal size of the heart. (orig.)

  17. Improved Root Normal Size Distributions for Liquid Atomization

    Science.gov (United States)

    2015-11-01

    ANSI Std. Z39.18 j CONVERSION TABLE Conversion Factors for U.S. Customary to metric (SI) units of measurement. MULTIPLY BY TO...Gray (Gy) coulomb /kilogram (C/kg) second (s) kilogram (kg) kilo pascal (kPa) 1 Improved Root Normal Size Distributions for Liquid

  18. On fully stressed design and p-norm measures in structural optimization

    DEFF Research Database (Denmark)

    Zhou, Mingdong; Sigmund, Ole

    2017-01-01

    This brief note revisits the fully stressed design schemes and p-norm measures used in stress-based structural optimization. Two simple shape optimization cases are used to remind the reader that fully stressed designs only are optimal when unimpeded by geometrical restrictions and that high valu...... of the stress norm are needed in order to achieve satisfactory designs....

  19. Operational Testing and Measurement of the Resolving Time of a Counting Assembly

    International Nuclear Information System (INIS)

    Manent, G.; Scheemaecker, J. de

    1968-01-01

    An experiment is described which constitutes a very sensitive test of the satisfactory operation of a counting assembly. It makes it possible to measure the resolving time of an assembly to an accuracy of 1 per cent. A certain number of examples are presented which show the sensitivity of the test. (author) [fr

  20. Evaluation of temporal bone pneumatization on high resolution CT (HRCT) measurements of the temporal bone in normal and otitis media group and their correlation to measurements of internal auditory meatus, vestibular or cochlear aqueduct

    International Nuclear Information System (INIS)

    Nakamura, Miyako

    1988-01-01

    High resolution CT axial scans were made at the three levels of the temoral bone 91 cases. These cases consisted of 109 sides of normal pneumatization (NR group) and 73 of poor pneumatization resulted by chronic otitis (OM group). NR group included sensorineural hearing loss cases and/or sudden deafness on the side. Three levels of continuous slicing were chosen at the internal auditory meatus, the vestibular and the cochlear aqueduct, respectively. In each slice two sagittal and two horizontal measurements were done on the outer contour of the temporal bone. At the proper level, diameter as well as length of the internal acoustic meatus, the vestibular or the cochlear aqueduct were measured. Measurements of the temporal bone showed statistically significant difference between NR and OM groups. Correlation of both diameter and length of the internal auditory meatus to the temporal bone measurements were statistically significant. Neither of measurements on the vestibular or the cochlear aqueduct showed any significant correlation to that of the temporal bone. (author)

  1. Normal modes of weak colloidal gels

    Science.gov (United States)

    Varga, Zsigmond; Swan, James W.

    2018-01-01

    The normal modes and relaxation rates of weak colloidal gels are investigated in calculations using different models of the hydrodynamic interactions between suspended particles. The relaxation spectrum is computed for freely draining, Rotne-Prager-Yamakawa, and accelerated Stokesian dynamics approximations of the hydrodynamic mobility in a normal mode analysis of a harmonic network representing several colloidal gels. We find that the density of states and spatial structure of the normal modes are fundamentally altered by long-ranged hydrodynamic coupling among the particles. Short-ranged coupling due to hydrodynamic lubrication affects only the relaxation rates of short-wavelength modes. Hydrodynamic models accounting for long-ranged coupling exhibit a microscopic relaxation rate for each normal mode, λ that scales as l-2, where l is the spatial correlation length of the normal mode. For the freely draining approximation, which neglects long-ranged coupling, the microscopic relaxation rate scales as l-γ, where γ varies between three and two with increasing particle volume fraction. A simple phenomenological model of the internal elastic response to normal mode fluctuations is developed, which shows that long-ranged hydrodynamic interactions play a central role in the viscoelasticity of the gel network. Dynamic simulations of hard spheres that gel in response to short-ranged depletion attractions are used to test the applicability of the density of states predictions. For particle concentrations up to 30% by volume, the power law decay of the relaxation modulus in simulations accounting for long-ranged hydrodynamic interactions agrees with predictions generated by the density of states of the corresponding harmonic networks as well as experimental measurements. For higher volume fractions, excluded volume interactions dominate the stress response, and the prediction from the harmonic network density of states fails. Analogous to the Zimm model in polymer

  2. A novel photoplethysmography technique to derive normalized arterial stiffness as a blood pressure independent measure in the finger vascular bed

    International Nuclear Information System (INIS)

    Tanaka, Gohichi; Sawada, Yukihiro; Kato, Yuichi; Yamakoshi, Ken-ichi; Matsumura, Kenta; Maeda, Kimihito; Horiguchi, Masami; Ohguro, Hiroshi

    2011-01-01

    Stiffening of the small artery may be the earliest sign of arteriosclerosis. However, there is no adequate method for directly assessing small arterial stiffness. In this study, the finger arterial elasticity index (FEI) was defined as the parameter n which denotes the curvilinearity of an exponential model of pressure (P)–volume (V a ) relationship (V a = a − b exp (−nP)). For the original estimation, the FEI was calculated from a compliance index from the finger photoplethysmogram whilst occluding the finger. A simple estimation of the FEI was devised by utilizing normalized pulse volume instead of the compliance index. Both estimations yielded close agreement with the exponential model in healthy young participants (study 1: n = 19). Since the FEI was dependent on finger mean blood pressure, normalized finger arterial stiffness index (FSI) was defined as standardized residual from their relationship: mean and standard deviation (SD) of the FSI were 50 ± 10 (study 2: n = 174). The mean coefficient of variation of the FSI for four measurements was 5.72% (study 3: n = 6). The mean and SD of the FSI in seven arteriosclerotic patients were 100.0 ± 13.5. In conclusion, the FEI and FSI by simple estimation are valid and useful for arteriosclerosis research

  3. In vivo bleeding time and in vitro thrombelastography measurements are better indicators of dilutional hypothermic coagulopathy than prothrombin time.

    Science.gov (United States)

    Kheirabadi, Bijan S; Crissey, Jacqueline M; Deguzman, Rodolfo; Holcomb, John B

    2007-06-01

    The coagulopathy of trauma is generally confirmed by prothrombin time (PT) > or =16 seconds or an international normalized ratio > or =1.5. However, the utility of these values as a screening test is unknown. We examined different coagulation tests to determine the best predictor of coagulopathic bleeding and mortality in a small animal hemorrhage model. Coagulopathy was induced in male New Zealand White rabbits by warfarin (W; 2 mg/kg for 2 days; n = 7), or hemodilution and hypothermia (HH; 50% blood exchange with Hextend, 34.5 +/- 0.3 degrees C; n = 7). Normal (N) rabbits without pretreatment served as the control (n = 7). Blood samples collected after coagulopathy induction and analyzed by prothrombin time (PT), activated partial thromboplastin time (aPTT), and thromboelastography (TEG) tests. Liver bleeding time (BT) was also measured before injury. An uncontrolled hemorrhage was created by a longitudinal splenic incision and the abdomen was closed. Rabbits were resuscitated with Hextend solution (25 mL/kg) to return blood pressure to baseline and monitored for 2 hours or until death at which time blood loss was measured. Warfarin-induced coagulopathy increased BT, PT, and aPTT. TEG showed increased reaction (R) and clot formation (K) times and marked decrease in clotting rate (alpha angle and Vmax). Hemodilution hypothermia coagulopathy increased only BT and aPTT, and decreased the clotting rate (alpha angle and Vmax) and strength of the clot. After injury, blood losses were higher in coagulopathic rabbits (W = 54.6 +/- 4.2 and HH = 51.1 +/- 8.9 mL/kg) than in normal rabbits (30.6 +/- 12.4 mL/kg) and resulted in 86%, 100%, and 0% death, respectively. BT and Vmax consistently predicted coagulopathic bleeding and death in all animals. Although satisfactory in warfarin-induced coagulopathy, PT was not a valid screening test for dilutional and hypothermic coagulopathy. BT and TEG measurements of blood clotting rate are better indicators of coagulopathic bleeding

  4. Regional ADC values of the normal brain: differences due to age, gender, and laterality

    Energy Technology Data Exchange (ETDEWEB)

    Naganawa, Shinji; Ishigaki, Takeo [Department of Radiology, Nagoya University School of Medicine, 65 Tsurumai-cho, Shouwa-ku, Nagoya 466-8550 (Japan); Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo [Department of Radiology, First Kamiida General Hospital (Japan)

    2003-01-01

    The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean{+-}standard deviation 2.3{+-}1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (p<0.01). In the subjects under 60 years, women showed higher values in right frontal, bilateral thalamus, and temporal (p<0.01); however, in the subjects over 60 years, no region showed difference between men and women. The knowledge obtained in this study may be helpful to understand the developmental and aging mechanisms of normal brain and may be useful for the future quantitative study as a reference. (orig.)

  5. Regional ADC values of the normal brain: differences due to age, gender, and laterality

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Ishigaki, Takeo; Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo

    2003-01-01

    The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean±standard deviation 2.3±1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (p<0.01). In the subjects under 60 years, women showed higher values in right frontal, bilateral thalamus, and temporal (p<0.01); however, in the subjects over 60 years, no region showed difference between men and women. The knowledge obtained in this study may be helpful to understand the developmental and aging mechanisms of normal brain and may be useful for the future quantitative study as a reference. (orig.)

  6. Impact of age and sex on normal left heart structure and function.

    Science.gov (United States)

    Hagström, Linn; Henein, Michael Y; Karp, Kjell; Waldenström, Anders; Lindqvist, Per

    2017-11-01

    Accurate age- and sex-related normal reference values of ventricular structure and function are important to determine the level of dysfunction in patients. The aim of this study therefore was to document normal age range sex-related measurements of LV structural and functional measurements to serve such purpose. We evaluated left ventricular structure and function in 293 healthy subjects between 20 and 90 years with equally distributed gender. Doppler echocardiography was used including measure of both systolic and diastolic functions. Due to systolic LV function, only long axis function correlated with age (r = 0·55, P<0·01) and the correlation was stronger in females. Concerning diastolic function, there was a strong age correlation in all parameters used (r = 0·40-0·74, P<0·001). Due to LV structural changes over age, females showed a larger reduction in end-diastolic volumes, but no or trivial difference in wall thickness after the age of 60 years. Age is associated with significant normal changes in left ventricular structure and function, which should be considered when deciding on normality. These changes are related to systemic arterial changes as well as body stature, thus reflecting overall body ageing process. Furthermore, normal cardiac ageing in females might partly explain the higher prevalence of heart failure with preserved ejection in females. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  7. Normalized Noise Power Spectrum of Full Field Digital Mammography System

    International Nuclear Information System (INIS)

    Isa, Norriza Mohd; Wan Hassan, Wan Muhamad Saridan

    2010-01-01

    A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

  8. Comparison of radiosensitivities of human autologous normal and neoplastic thyroid epithelial cells

    International Nuclear Information System (INIS)

    Miller, R.C.; Kopecky, K.J.; Hiraoka, T.; Ezaki, H.; Clifton, K.H.

    1986-01-01

    Studies were conducted to examine differences between the radiosensitivities of normal and neoplastic epithelial cells of the human thyroid. Freshly excised thyroid tissues from the tumours of eight patients with papillary carcinoma (PC) and five with follicular adenoma (FA) were cultured in vitro separately from normal thyroid tissue obtained from the surgical margins of the same patients. Plating efficiency of unirradiated control tissue was lower, on average for tumour tissue compared with normal tissue. Radiosensitivity, measured by the 37% inactivation dose D 0 , was greater for carcinoma tissue than for normal tissue in seven out of eight PC cases. Adenomatous tissue was less radiosensitive than normal tissue in four out of five FA cases. This is the first report comparing the radiosensitivity of autologous normal and abnormal epithelial tissue from the human thyroid. (author)

  9. Bicervical normal uterus with normal vagina | Okeke | Annals of ...

    African Journals Online (AJOL)

    To the best of our knowledge, only few cases of bicervical normal uterus with normal vagina exist in the literature; one of the cases had an anterior‑posterior disposition. This form of uterine abnormality is not explicable by the existing classical theory of mullerian anomalies and suggests that a complex interplay of events ...

  10. Magnetic resonance imaging in patients with unstable angina: comparison with acute myocardial infarction and normals

    International Nuclear Information System (INIS)

    Ahmad, M.; Johnson, R.F. Jr.; Fawcett, H.D.; Schreiber, M.H.

    1988-01-01

    The role of magnetic resonance imaging in characterizing normal, ischemic and infarcted segments of myocardium was examined in 8 patients with unstable angina, 11 patients with acute myocardial infarction, and 7 patients with stable angina. Eleven normal volunteers were imaged for comparison. Myocardial segments in short axis magnetic resonance images were classified as normal or abnormal on the basis of perfusion changes observed in thallium-201 images in 22 patients and according to the electrocariographic localization of infarction in 4 patients. T2 relaxation time was measured in 57 myocardial segments with abnormal perfusion (24 with reversible and 33 with irreversible perfusion changes) and in 25 normally perfused segments. T2 measurements in normally perfused segments of patients with acute myocardial infarction, unstable angina and stable angina were within normal range derived from T2 measurements in 48 myocardial segments of 11 normal volunteers (42 +/- 10 ms). T2 in abnormal myocardial segments of patients with stable angina also was not significantly different from normal. T2 of abnormal segments in patients with unstable angina (64 +/- 14 in reversibly ischemic and 67 +/- 21 in the irreversibly ischemic segments) was prolonged when compared to normal (p less than 0.0001) and was not significantly different from T2 in abnormal segments of patients with acute myocardial infarction (62 +/- 18 for reversibly and 66 +/- 11 for irreversibly ischemic segments). The data indicate that T2 prolongation is not specific for acute myocardial infarction and may be observed in abnormally perfused segments of patients with unstable angina

  11. Normal tissue dose-effect models in biological dose optimisation

    International Nuclear Information System (INIS)

    Alber, M.

    2008-01-01

    Sophisticated radiotherapy techniques like intensity modulated radiotherapy with photons and protons rely on numerical dose optimisation. The evaluation of normal tissue dose distributions that deviate significantly from the common clinical routine and also the mathematical expression of desirable properties of a dose distribution is difficult. In essence, a dose evaluation model for normal tissues has to express the tissue specific volume effect. A formalism of local dose effect measures is presented, which can be applied to serial and parallel responding tissues as well as target volumes and physical dose penalties. These models allow a transparent description of the volume effect and an efficient control over the optimum dose distribution. They can be linked to normal tissue complication probability models and the equivalent uniform dose concept. In clinical applications, they provide a means to standardize normal tissue doses in the face of inevitable anatomical differences between patients and a vastly increased freedom to shape the dose, without being overly limiting like sets of dose-volume constraints. (orig.)

  12. Improving the dictionary lookup approach for disease normalization using enhanced dictionary and query expansion.

    Science.gov (United States)

    Jonnagaddala, Jitendra; Jue, Toni Rose; Chang, Nai-Wen; Dai, Hong-Jie

    2016-01-01

    The rapidly increasing biomedical literature calls for the need of an automatic approach in the recognition and normalization of disease mentions in order to increase the precision and effectivity of disease based information retrieval. A variety of methods have been proposed to deal with the problem of disease named entity recognition and normalization. Among all the proposed methods, conditional random fields (CRFs) and dictionary lookup method are widely used for named entity recognition and normalization respectively. We herein developed a CRF-based model to allow automated recognition of disease mentions, and studied the effect of various techniques in improving the normalization results based on the dictionary lookup approach. The dataset from the BioCreative V CDR track was used to report the performance of the developed normalization methods and compare with other existing dictionary lookup based normalization methods. The best configuration achieved an F-measure of 0.77 for the disease normalization, which outperformed the best dictionary lookup based baseline method studied in this work by an F-measure of 0.13.Database URL: https://github.com/TCRNBioinformatics/DiseaseExtract. © The Author(s) 2016. Published by Oxford University Press.

  13. A study on brain ventricle measurement of normal Korean adults using computed tomography

    International Nuclear Information System (INIS)

    Kim, Ung Jin; Chang, Kee Hyun; Han, Man Chung

    1981-01-01

    The study was undertaken to assess the ventricular system of the brain in normal Korean adults on the base of computed tomography. The computerized tomographic examinations of 334 Korean adults between ages of 15 to 50 years, performed at Seoul National University Hospital, were evaluated. The cerebro- or cerebello-ventricular ratio, between ventricular size and brain parenchyme width, has been known to be a reliable indicator of the ventricular size. This ratio was measured at the level of the lateral, third and fourth ventricles respectively. The shape of the quardigeminal and suprasellar cistern was analyzed. The results are as follows: 1. The cerebroventricular ratios of the lateral ventricle at the level of the widest bifrontal and bicaudate diameters were 0.30 ± 0.04 and 0.14 ± 0.02, respectively. The lateral ventricle was asymmetric in 12.6%, of which the left side was usually larger than the right. 2. There was correlation between the cerebroventricular ratio and age, i.e., with increase of age, the C-V ratio increased slightly. 3. The cerebroventricular ratio of the third ventricle was 0.03 ± 0.01. 4. The cerebroventricular ratio of the fourth ventricle in width and height was 0.14± 0.02 and 0.10 ± 0.03, respectively. The anteroposterior position index of the fourth ventricle was 0.42 ± 0.04. 5. The quadrigeminal cistern showed W-shape in 76.6% and U-shape in 23.4%. 6. The suprasellar cistern showed pentagonal shape in 61.1%, round in 28.4% and hexagonal in 10.5%. 7. There was no significant difference between male and female according to the above results

  14. A study on brain ventricle measurements of normal Korean adults using computed tomography

    International Nuclear Information System (INIS)

    Kim, Ung Jin; Chang, Kee Hyun; Han, Man Chung

    1981-01-01

    The study was undertaken to assess the ventricular system of the brain in normal Korean adults on the base of computed tomography. The computerized tomographic examinations of 334 Korean adults between ages of 15 to 50 years, performed at Seoul National University Hospital, were evaluated. The cerebro- or cerebello-ventricular ratio, between ventricular size and brain parenchyme width, has been known to be reliable indicator of the ventricular size. This ratio was measured at the level of the lateral, third and fourth ventricles respectively. The shape of the quardigeminal and suprasellar cistern was analyzed. The results are as follows: 1. The cerebroventricular ratios of the lateral ventricle at the level of the widest bifrontal and bicaudate diameters were 0.30 ± 0.04 and 0.14 ± 0.02, respectively. The lateral ventricle was asymmetric in 12.6%, of which the left side was usually larger than the right. 2. There was correlation between the cerebroventricular ratio and age, i.e., with increase of age, the C-V ratio increased slightly. 3. The cerebrocventricular ratio of the third ventricle was 0.03 ± 0.01. 4. The cerebroventricular ratio of the fourth ventricle in width and height was 0.14 ± 0.02 and 0.10 ± 0.03, respectively. The anteroposterior position index of the fourth ventricle was 0.42 ± 0.04. 5. The quadrigeminal cistern showed W-shape in 76.6% and U-shaped in 23.4%. 6. The suprasellar cistern showed pentagonal shape in 61.1%, round in 28.4% and hexagonal in 10.5%. 7. There was no significant difference between male and female according to the above results

  15. Size-independent peak shift between normal and upconversion ...

    Indian Academy of Sciences (India)

    2014-02-12

    Feb 12, 2014 ... In this article, we report size-dependent measurement of the shift in peak of upconversion photoluminescence spectra compared to that of normal photoluminescence using a 800 nm femtosecond laser and its second harmonic. It has been shown that the upconversion photoluminescence is always ...

  16. Comparative measurement of ghrelin, leptin, adiponectin, EGF and IGF-1 in breast milk of mothers with overweight/obese and normal-weight infants.

    Science.gov (United States)

    Khodabakhshi, A; Ghayour-Mobarhan, M; Rooki, H; Vakili, R; Hashemy, S-I; Mirhafez, S R; Shakeri, M-T; Kashanifar, R; Pourbafarani, R; Mirzaei, H; Dahri, M; Mazidi, M; Ferns, G; Safarian, M

    2015-05-01

    Obese infants are more susceptible to develop adulthood obesity and its related comorbidities. Previous studies have shown the presence of hormones and growth factors in maternal breast milk that may influence infant adiposity. The aim of this study was to investigate differences in concentrations of three hormones and two growth factors in the breast milk of mothers with obese and non-obese infants. In this cross-sectional study, 40 mothers with overweight or obese infants (weight for length percentile >97) and 40 age-matched mothers with normal-weight infant (-10 milk concentrations of ghrelin and adiponectin, leptin, epithelial growth factor (EGF) and insulin-like growth factor-1 (IGF-1) were measured using enzyme-linked immunosorbent assay methods. The mean breast milk concentration of ghrelin was higher in mothers with normal-weight infants, 137.50 pg/ml, than in mothers with obese infants, 132.00 pg/ml (P=0.001). This was also true regarding the concentration of EGF in mothers with (0/04 ng/ml) and without (0/038 ng/ml) normal-weight infants (P=0.01). No significant differences were observed in concentrations of leptin, adiponectin and IGF-1 between two groups (P > 0.05). There was also a significant positive correlation between EGF and ghrelin in both groups. This study revealed that there was a correlation between ghrelin and EGF level in breast milk of mothers with obese and non-obese infants, suggesting a possible regulatory effect of these two hormones on weight in infants.

  17. Riboflavin/UVA Collagen Cross-Linking-Induced Changes in Normal and Keratoconus Corneal Stroma

    Science.gov (United States)

    Hayes, Sally; Boote, Craig; Kamma-Lorger, Christina S.; Rajan, Madhavan S.; Harris, Jonathan; Dooley, Erin; Hawksworth, Nicholas; Hiller, Jennifer; Terill, Nick J.; Hafezi, Farhad; Brahma, Arun K.; Quantock, Andrew J.; Meek, Keith M.

    2011-01-01

    Purpose To determine the effect of Ultraviolet-A collagen cross-linking with hypo-osmolar and iso-osmolar riboflavin solutions on stromal collagen ultrastructure in normal and keratoconus ex vivo human corneas. Methods Using small-angle X-ray scattering, measurements of collagen D-periodicity, fibril diameter and interfibrillar spacing were made at 1 mm intervals across six normal post-mortem corneas (two above physiological hydration (swollen) and four below (unswollen)) and two post-transplant keratoconus corneal buttons (one swollen; one unswollen), before and after hypo-osmolar cross-linking. The same parameters were measured in three other unswollen normal corneas before and after iso-osmolar cross-linking and in three pairs of swollen normal corneas, in which only the left was cross-linked (with iso-osmolar riboflavin). Results Hypo-osmolar cross-linking resulted in an increase in corneal hydration in all corneas. In the keratoconus corneas and unswollen normal corneas, this was accompanied by an increase in collagen interfibrillar spacing (priboflavin solutions are more likely a consequence of treatment-induced changes in tissue hydration rather than cross-linking. PMID:21850225

  18. A study on normal value of eyeball protrusion in Korean adult using CT

    International Nuclear Information System (INIS)

    Song, Chi Sung; Chang, Kee Hyun

    1984-01-01

    CT may be valuably used in determination of proptosis. Normal value of eyeball protrusion was measured in normal Koreans using CT. Among 86 Koreans, 26 have normal both eyes, but 60 have one normal eye with one abnormal eye (chiefly, proptosis and and eyeball tumor). The results of 112 eyes are as follows: Absolute measurement of 'a', that is, the distance between cornea and IZL (interzygomatic line) is 16.0±3.4 mm in male (for 63 eye), 15.7±4.0 mm in female for 49 eyes. Ratio of 'a' over 'A' (A-P diameter of eyeball) is 57±12% is male (for 63 eye), 57±14% in female (for 49 eye) Discrepancy of eyeball protrusion between both eyes is 0.67±1.5 mm (for 26 adults). Practically, normal range of eyeball prtotrusion ('a') is 12.6 mm < male < 19.4 mm, 11.7 mm < female < 19.7 mm. 'a/A' ratio over 70% and over 2mm discrepancy between both eyes are also suggested as genuine exophthalmos

  19. A dynamic-based measurement of a spring constant with a smartphone light sensor

    Science.gov (United States)

    Pili, Unofre

    2018-05-01

    An accessible smartphone-based experimental set-up for measuring a spring constant is presented. Using the smartphone ambient light sensor as the motion timer that allows for the measurement of the period of oscillations of a vertical spring-mass oscillator we found the spring constant to be 27.3 +/- 0.2 N m-1. This measurement is in a satisfactory agreement with another experimental value, 26.7 +/- 0.1 N m-1, obtained via the traditional static method.

  20. Multiple spacecraft observations of interplanetary shocks Four spacecraft determination of shock normals

    Science.gov (United States)

    Russell, C. T.; Mellott, M. M.; Smith, E. J.; King, J. H.

    1983-01-01

    ISEE 1, 2, 3, IMP 8, and Prognoz 7 observations of interplanetary shocks in 1978 and 1979 provide five instances where a single shock is observed by four spacecraft. These observations are used to determine best-fit normals for these five shocks. In addition to providing well-documented shocks for future investigations these data allow the evaluation of the accuracy of several shock normal determination techniques. When the angle between upstream and downstream magnetic field is greater than 20 deg, magnetic coplanarity can be an accurate single spacecraft method. However, no technique based solely on the magnetic measurements at one or multiple sites was universally accurate. Thus, the use of overdetermined shock normal solutions, utilizing plasma measurements, separation vectors, and time delays together with magnetic constraints, is recommended whenever possible.

  1. Smooth quantile normalization.

    Science.gov (United States)

    Hicks, Stephanie C; Okrah, Kwame; Paulson, Joseph N; Quackenbush, John; Irizarry, Rafael A; Bravo, Héctor Corrada

    2018-04-01

    Between-sample normalization is a critical step in genomic data analysis to remove systematic bias and unwanted technical variation in high-throughput data. Global normalization methods are based on the assumption that observed variability in global properties is due to technical reasons and are unrelated to the biology of interest. For example, some methods correct for differences in sequencing read counts by scaling features to have similar median values across samples, but these fail to reduce other forms of unwanted technical variation. Methods such as quantile normalization transform the statistical distributions across samples to be the same and assume global differences in the distribution are induced by only technical variation. However, it remains unclear how to proceed with normalization if these assumptions are violated, for example, if there are global differences in the statistical distributions between biological conditions or groups, and external information, such as negative or control features, is not available. Here, we introduce a generalization of quantile normalization, referred to as smooth quantile normalization (qsmooth), which is based on the assumption that the statistical distribution of each sample should be the same (or have the same distributional shape) within biological groups or conditions, but allowing that they may differ between groups. We illustrate the advantages of our method on several high-throughput datasets with global differences in distributions corresponding to different biological conditions. We also perform a Monte Carlo simulation study to illustrate the bias-variance tradeoff and root mean squared error of qsmooth compared to other global normalization methods. A software implementation is available from https://github.com/stephaniehicks/qsmooth.

  2. System for measuring spacer pin pitch in a nuclear fuel assembly

    International Nuclear Information System (INIS)

    Isono, Kenji; Tateishi, Yoshinori; Mano, Tadashi.

    1975-01-01

    Object: To reduce the period for discriminating whether or not spacer pin pitch is satisfactory by simultaneously inserting a number of reference rods into a nuclear fuel assembly spacer ring element of a reactor and arranging them such that they can be simultaneously withdrawn to simplify the withdrawing operation. Structure: A spacer provided with a ring element which clamps a nuclear fuel element is supported on a spacer support with a rod secured to the support as a guide and is secured to the support by securing means. A vertically movable structure with a reference rod provided upright and thru-holes formed in two support plates provided in the same row as the spacer ring element is operated by a fluid pressure mechanism to simultaneously insert the reference rod into the spacer ring element. The reference rod is mounted in support plates via ball bearings such that it is slightly movable in the horizontal direction, and it is aligned with respect to the core of the ring element. The intercore distance of the reference rod is measured with the reference rod inserted in the ring element, thereby measuring the space pin pitch. From the results of measurement, discrimination as to whether the spacer is satisfactory or not is made. (Kamimura, M.)

  3. Brain Tumor Therapy-Induced Changes in Normal-Appearing Brainstem Measured With Longitudinal Diffusion Tensor Imaging

    International Nuclear Information System (INIS)

    Hua Chiaho; Merchant, Thomas E.; Gajjar, Amar; Broniscer, Alberto; Zhang, Yong; Li Yimei; Glenn, George R.; Kun, Larry E.; Ogg, Robert J.

    2012-01-01

    Purpose: To characterize therapy-induced changes in normal-appearing brainstems of childhood brain tumor patients by serial diffusion tensor imaging (DTI). Methods and Materials: We analyzed 109 DTI studies from 20 brain tumor patients, aged 4 to 23 years, with normal-appearing brainstems included in the treatment fields. Those with medulloblastomas, supratentorial primitive neuroectodermal tumors, and atypical teratoid rhabdoid tumors (n = 10) received postoperative craniospinal irradiation (23.4–39.6 Gy) and a cumulative dose of 55.8 Gy to the primary site, followed by four cycles of high-dose chemotherapy. Patients with high-grade gliomas (n = 10) received erlotinib during and after irradiation (54–59.4 Gy). Parametric maps of fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were computed and spatially registered to three-dimensional radiation dose data. Volumes of interest included corticospinal tracts, medial lemnisci, and the pons. Serving as an age-related benchmark for comparison, 37 DTI studies from 20 healthy volunteers, aged 6 to 25 years, were included in the analysis. Results: The median DTI follow-up time was 3.5 years (range, 1.6–5.0 years). The median mean dose to the pons was 56 Gy (range, 7–59 Gy). Three patterns were seen in longitudinal FA and apparent diffusion coefficient changes: (1) a stable or normal developing time trend, (2) initial deviation from normal with subsequent recovery, and (3) progressive deviation without evidence of complete recovery. The maximal decline in FA often occurred 1.5 to 3.5 years after the start of radiation therapy. A full recovery time trend could be observed within 4 years. Patients with incomplete recovery often had a larger decline in FA within the first year. Radiation dose alone did not predict long-term recovery patterns. Conclusions: Variations existed among individual patients after therapy in longitudinal evolution of brainstem white matter injury and recovery. Early response

  4. Description of a Normal-Force In-Situ Turbulence Algorithm for Airplanes

    Science.gov (United States)

    Stewart, Eric C.

    2003-01-01

    A normal-force in-situ turbulence algorithm for potential use on commercial airliners is described. The algorithm can produce information that can be used to predict hazardous accelerations of airplanes or to aid meteorologists in forecasting weather patterns. The algorithm uses normal acceleration and other measures of the airplane state to approximate the vertical gust velocity. That is, the fundamental, yet simple, relationship between normal acceleration and the change in normal force coefficient is exploited to produce an estimate of the vertical gust velocity. This simple approach is robust and produces a time history of the vertical gust velocity that would be intuitively useful to pilots. With proper processing, the time history can be transformed into the eddy dissipation rate that would be useful to meteorologists. Flight data for a simplified research implementation of the algorithm are presented for a severe turbulence encounter of the NASA ARIES Boeing 757 research airplane. The results indicate that the algorithm has potential for producing accurate in-situ turbulence measurements. However, more extensive tests and analysis are needed with an operational implementation of the algorithm to make comparisons with other algorithms or methods.

  5. The thoracic paraspinal shadow: normal appearances.

    Science.gov (United States)

    Lien, H H; Kolbenstvedt, A

    1982-01-01

    The width of the right and left thoracic paraspinal shadows were measured at all levels in 200 presumably normal individuals. The paraspinal shadow could be identified in nearly all cases on the left side and in approximately one-third on the right. The range of variation was greater on the left side than one the right. The left paraspinal shadow was wider at the upper levels and in individuals above 40 years of age.

  6. Normal foot and ankle

    International Nuclear Information System (INIS)

    Weissman, S.D.

    1989-01-01

    The foot may be thought of as a bag of bones tied tightly together and functioning as a unit. The bones re expected to maintain their alignment without causing symptomatology to the patient. The author discusses a normal radiograph. The bones must have normal shape and normal alignment. The density of the soft tissues should be normal and there should be no fractures, tumors, or foreign bodies

  7. Relationship between hamstring length and gluteus maximus strength with and without normalization.

    Science.gov (United States)

    Lee, Dong-Kyu; Oh, Jae-Seop

    2018-01-01

    [Purpose] This study assessed the relationship between hamstring length and gluteus maximus (GM) strength with and without normalization by body weight and height. [Subjects and Methods] In total, 34 healthy male subjects volunteered for this study. To measure GM strength, subjects performed maximal hip joint extension with the knee joints flexed to 90° in the prone position. GM strength was normalized for body weight and height. [Results] GM strength with normalization was positively correlated with hamstring length, whereas GM strength without normalization was negatively correlated with hamstring length. [Conclusion] The normalization of GM strength by body weight and height has the potential to lead to more appropriate conclusions and interpretations about its correlation with hamstring length. Hamstring length may be related to GM strength.

  8. Cerebral blood flow measured by arterial spin labeling MRI at resting state in normal aging and Alzheimer's disease.

    Science.gov (United States)

    Zhang, Nan; Gordon, Marc L; Goldberg, Terry E

    2017-01-01

    Arterial spin labeling (ASL) magnetic resonance imaging uses arterial blood water as an endogenous tracer to measure cerebral blood flow (CBF). In this review, based on ASL studies in the resting state, we discuss state-of-the-art technical and data processing improvements in ASL, and ASL CBF changes in normal aging, mild cognitive impairment (MCI), Alzheimer's disease (AD), and other types of dementia. We propose that vascular and AD risk factors should be considered when evaluating CBF changes in aging, and that other validated biomarkers should be used as inclusion criteria or covariates when evaluating CBF changes in MCI and AD. With improvements in hardware and experimental design, ASL is proving to be an increasingly promising tool for exploring pathogenetic mechanisms, early detection, monitoring disease progression and pharmacological response, and differential diagnosis of AD. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Detection of a normal zone in the MFTF magnets

    International Nuclear Information System (INIS)

    Owen, E.W.

    1979-01-01

    A method is described for the electrical detection of a normal zone in inductively coupled superconducting coils. Measurements are made with two kinds of bridges, mutual inductance bridges and self-inductance bridges. The bridge outputs are combined with other measured voltages to form a detector that can be realized with either analog circuits or a computer algorithm. The detection of a normal zone in a pair of coupled coils, each with taps, is discussed in detail. It is also shown that the method applies to a pair of coils when one has no taps and to a pair when one coil is superconducting and the other is not. The method is extended, in principle, to a number of coils. A description is given of a technique for balancing the bridges at near the operating currents of the coils

  10. Normal Hg uptake values in children under 4 years old

    International Nuclear Information System (INIS)

    Raynaud, C.

    1976-01-01

    At birth the child's kidney is anatomically and functionally immature and the Hg uptake rate is only a quarter that of an adult. At 12 months this value is already 3/4 that of the adult and the final normal mature values are reached between 3 and 4 years. A curve of normal values for children below 4 years old is proposed, though being based on a small number of measurements only it must be taken as provisional [fr

  11. Superfluid to normal phase transition and extreme regularity od superdeformed bands

    CERN Document Server

    Pavlichenkov, I M

    2002-01-01

    The exact semiclassical expression for the second inertial parameter B for the superfluid and normal phases is derived. Interpolation between these limiting values shows that the function B(I) changes sign at the spin I sub c , which is critical for a rotational spectrum. The quantity B turns out to be a sensitive measure of the change in static pairing correlations. The superfluid-to-normal transition reveals itself in the specific variation of the ratio B/A versus spin I with the plateau characteristic of the normal phase. This dependence is find to be universal for normal deformed and superdeformed nuclei. The long plateau with a small value B/A approx A sup - sup 8 sup / sup 3 explains the extreme regularity of superdeformed bands

  12. Evaluating acoustic speaker normalization algorithms: evidence from longitudinal child data.

    Science.gov (United States)

    Kohn, Mary Elizabeth; Farrington, Charlie

    2012-03-01

    Speaker vowel formant normalization, a technique that controls for variation introduced by physical differences between speakers, is necessary in variationist studies to compare speakers of different ages, genders, and physiological makeup in order to understand non-physiological variation patterns within populations. Many algorithms have been established to reduce variation introduced into vocalic data from physiological sources. The lack of real-time studies tracking the effectiveness of these normalization algorithms from childhood through adolescence inhibits exploration of child participation in vowel shifts. This analysis compares normalization techniques applied to data collected from ten African American children across five time points. Linear regressions compare the reduction in variation attributable to age and gender for each speaker for the vowels BEET, BAT, BOT, BUT, and BOAR. A normalization technique is successful if it maintains variation attributable to a reference sociolinguistic variable, while reducing variation attributable to age. Results indicate that normalization techniques which rely on both a measure of central tendency and range of the vowel space perform best at reducing variation attributable to age, although some variation attributable to age persists after normalization for some sections of the vowel space. © 2012 Acoustical Society of America

  13. Patterns of brain structural connectivity differentiate normal weight from overweight subjects.

    Science.gov (United States)

    Gupta, Arpana; Mayer, Emeran A; Sanmiguel, Claudia P; Van Horn, John D; Woodworth, Davis; Ellingson, Benjamin M; Fling, Connor; Love, Aubrey; Tillisch, Kirsten; Labus, Jennifer S

    2015-01-01

    Alterations in the hedonic component of ingestive behaviors have been implicated as a possible risk factor in the pathophysiology of overweight and obese individuals. Neuroimaging evidence from individuals with increasing body mass index suggests structural, functional, and neurochemical alterations in the extended reward network and associated networks. To apply a multivariate pattern analysis to distinguish normal weight and overweight subjects based on gray and white-matter measurements. Structural images (N = 120, overweight N = 63) and diffusion tensor images (DTI) (N = 60, overweight N = 30) were obtained from healthy control subjects. For the total sample the mean age for the overweight group (females = 32, males = 31) was 28.77 years (SD = 9.76) and for the normal weight group (females = 32, males = 25) was 27.13 years (SD = 9.62). Regional segmentation and parcellation of the brain images was performed using Freesurfer. Deterministic tractography was performed to measure the normalized fiber density between regions. A multivariate pattern analysis approach was used to examine whether brain measures can distinguish overweight from normal weight individuals. 1. White-matter classification: The classification algorithm, based on 2 signatures with 17 regional connections, achieved 97% accuracy in discriminating overweight individuals from normal weight individuals. For both brain signatures, greater connectivity as indexed by increased fiber density was observed in overweight compared to normal weight between the reward network regions and regions of the executive control, emotional arousal, and somatosensory networks. In contrast, the opposite pattern (decreased fiber density) was found between ventromedial prefrontal cortex and the anterior insula, and between thalamus and executive control network regions. 2. Gray-matter classification: The classification algorithm, based on 2 signatures with 42 morphological features, achieved 69

  14. Patterns of brain structural connectivity differentiate normal weight from overweight subjects

    Science.gov (United States)

    Gupta, Arpana; Mayer, Emeran A.; Sanmiguel, Claudia P.; Van Horn, John D.; Woodworth, Davis; Ellingson, Benjamin M.; Fling, Connor; Love, Aubrey; Tillisch, Kirsten; Labus, Jennifer S.

    2015-01-01

    Background Alterations in the hedonic component of ingestive behaviors have been implicated as a possible risk factor in the pathophysiology of overweight and obese individuals. Neuroimaging evidence from individuals with increasing body mass index suggests structural, functional, and neurochemical alterations in the extended reward network and associated networks. Aim To apply a multivariate pattern analysis to distinguish normal weight and overweight subjects based on gray and white-matter measurements. Methods Structural images (N = 120, overweight N = 63) and diffusion tensor images (DTI) (N = 60, overweight N = 30) were obtained from healthy control subjects. For the total sample the mean age for the overweight group (females = 32, males = 31) was 28.77 years (SD = 9.76) and for the normal weight group (females = 32, males = 25) was 27.13 years (SD = 9.62). Regional segmentation and parcellation of the brain images was performed using Freesurfer. Deterministic tractography was performed to measure the normalized fiber density between regions. A multivariate pattern analysis approach was used to examine whether brain measures can distinguish overweight from normal weight individuals. Results 1. White-matter classification: The classification algorithm, based on 2 signatures with 17 regional connections, achieved 97% accuracy in discriminating overweight individuals from normal weight individuals. For both brain signatures, greater connectivity as indexed by increased fiber density was observed in overweight compared to normal weight between the reward network regions and regions of the executive control, emotional arousal, and somatosensory networks. In contrast, the opposite pattern (decreased fiber density) was found between ventromedial prefrontal cortex and the anterior insula, and between thalamus and executive control network regions. 2. Gray-matter classification: The classification algorithm, based on 2 signatures with 42

  15. Quantum mechanical irreversibility and measurement

    CERN Document Server

    Grigolini, P

    1993-01-01

    This book is intended as a tutorial approach to some of the techniques used to deal with quantum dissipation and irreversibility, with special focus on their applications to the theory of measurements. The main purpose is to provide readers without a deep expertise in quantum statistical mechanics with the basic tools to develop a critical judgement on whether the major achievements in this field have to be considered a satisfactory solution of quantum paradox, or rather this ambitious achievement has to be postponed to when a new physics, more general than quantum and classical physics, will

  16. Normalized noise power spectrum of full field digital mammography system

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Wan Muhamad Saridan Wan Hassan

    2009-01-01

    A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (Author)

  17. Measurement of safety-rod effectiveness of the zero energy reactor 'RB'

    Energy Technology Data Exchange (ETDEWEB)

    Raisic, N; Popovic, D; Takac, S; Markovic, H; Martinc, R; Radmanovic, Lj [Boris Kidric Institute of Nuclear Sciences, Vinca, Beograd (Yugoslavia)

    1959-03-15

    The reactivity effectiveness of the two safety rods displaced eccentrically along diameter of a cylindrical D{sub 2}O moderated reactor was measured and compared with the theoretical calculations. The results show that the simplified calculations of one rod effectiveness are quite satisfactory but the theoretical evaluation of the interference effect of the two rods are not sufficiently reliable. (author)

  18. Next-to-next-leading order correction to 3-jet rate and event-shape ...

    Indian Academy of Sciences (India)

    portunity to test QCD by measuring the energy dependence of different ... event shape data was not satisfactory largely due to the scale uncertainty of the pertur- .... )3 d ¯C dy. + O. ( α4 s. ) . (5). Here the event-shape distribution is normalized to the ..... [1] A Gehrmann-De Ridder, T Gehrmann, E W N Glover and G Heinrich, J.

  19. Telomere length in normal and neoplastic canine tissues.

    Science.gov (United States)

    Cadile, Casey D; Kitchell, Barbara E; Newman, Rebecca G; Biller, Barbara J; Hetler, Elizabeth R

    2007-12-01

    To determine the mean telomere restriction fragment (TRF) length in normal and neoplastic canine tissues. 57 solid-tissue tumor specimens collected from client-owned dogs, 40 samples of normal tissue collected from 12 clinically normal dogs, and blood samples collected from 4 healthy blood donor dogs. Tumor specimens were collected from client-owned dogs during diagnostic or therapeutic procedures at the University of Illinois Veterinary Medical Teaching Hospital, whereas 40 normal tissue samples were collected from 12 control dogs. Telomere restriction fragment length was determined by use of an assay kit. A histologic diagnosis was provided for each tumor by personnel at the Veterinary Diagnostic Laboratory at the University of Illinois. Mean of the mean TRF length for 44 normal samples was 19.0 kilobases (kb; range, 15.4 to 21.4 kb), and the mean of the mean TRF length for 57 malignant tumors was 19.0 kb (range, 12.9 to 23.5 kb). Although the mean of the mean TRF length for tumors and normal tissues was identical, tumor samples had more variability in TRF length. Telomerase, which represents the main mechanism by which cancer cells achieve immortality, is an attractive therapeutic target. The ability to measure telomere length is crucial to monitoring the efficacy of telomerase inhibition. In contrast to many other mammalian species, the length of canine telomeres and the rate of telomeric DNA loss are similar to those reported in humans, making dogs a compelling choice for use in the study of human anti-telomerase strategies.

  20. Best-Matched Internal Standard Normalization in Liquid Chromatography-Mass Spectrometry Metabolomics Applied to Environmental Samples.

    Science.gov (United States)

    Boysen, Angela K; Heal, Katherine R; Carlson, Laura T; Ingalls, Anitra E

    2018-01-16

    The goal of metabolomics is to measure the entire range of small organic molecules in biological samples. In liquid chromatography-mass spectrometry-based metabolomics, formidable analytical challenges remain in removing the nonbiological factors that affect chromatographic peak areas. These factors include sample matrix-induced ion suppression, chromatographic quality, and analytical drift. The combination of these factors is referred to as obscuring variation. Some metabolomics samples can exhibit intense obscuring variation due to matrix-induced ion suppression, rendering large amounts of data unreliable and difficult to interpret. Existing normalization techniques have limited applicability to these sample types. Here we present a data normalization method to minimize the effects of obscuring variation. We normalize peak areas using a batch-specific normalization process, which matches measured metabolites with isotope-labeled internal standards that behave similarly during the analysis. This method, called best-matched internal standard (B-MIS) normalization, can be applied to targeted or untargeted metabolomics data sets and yields relative concentrations. We evaluate and demonstrate the utility of B-MIS normalization using marine environmental samples and laboratory grown cultures of phytoplankton. In untargeted analyses, B-MIS normalization allowed for inclusion of mass features in downstream analyses that would have been considered unreliable without normalization due to obscuring variation. B-MIS normalization for targeted or untargeted metabolomics is freely available at https://github.com/IngallsLabUW/B-MIS-normalization .

  1. Assessment of retinal sensitivity using a time-saving strategy in normal individuals

    Directory of Open Access Journals (Sweden)

    Suzumura H

    2012-11-01

    Full Text Available Hirotaka Suzumura,1 Keiji Yoshikawa,2 Shiro Mizoue,3 Ryoko Hyodo,4 Tairo Kimura5 1Eye Department, Nakano General Hospital, Tokyo, 2Yoshikawa Eye Clinic, Tokyo, 3Department of Ophthalmology, Ehime University, Ehime, 4Eye Department, Minami Matsuyama Hospital, Ehime, 5Ueno Eye Clinic, Tokyo, JapanBackground: The purpose of this study was to compare retinal sensitivities in normal individuals obtained using the Swedish Interactive Threshold Algorithm Standard (SITA-S on the Humphrey field analyzer with those obtained using the Dynamic strategy on the Octopus.Methods: Prior to visual field examinations, the background luminance, stimulus size, and exposure time with the Octopus 101 were conformed to the Humphrey field analyzer II settings. Volunteers over 20 years of age without apparent ophthalmic abnormalities were examined with the SITA-S central 30-2 program followed by the Dynamic 32 program. Eye with corrected visual acuity ≥0.8, refraction ≥ −6.0 diopters, and fields with satisfactory levels of reliability in SITA-S and Dynamic were selected.Results: Sixty-seven eyes from 67 normal individuals of mean age 51.3 ± 16.3 (range 22–76 years satisfied the selection criteria and were analyzed. Mean retinal sensitivity was significantly (P < 0.0001 higher with SITA-S (29.0 ± 2.4 dB than with Dynamic (26.8 ± 2.1 dB. Changes in retinal sensitivity with increasing age were significantly (P = 0.0003 greater with Dynamic (−0.09 ± 0.04 dB/year; 95% confidence interval [CI] −0.10 to −0.08 dB/year than with SITA-S (−0.07 ± 0.04 dB/year, 95% CI −0.08 to −0.06 dB/year. When classifying the visual field into three areas (central, mid-peripheral, and peripheral, retinal sensitivities with SITA-S were significantly higher in all areas than with Dynamic (P < 0.0001 for all three areas.Conclusion: Differences in Dynamic and SITA-S strategies may contribute to the differences in retinal sensitivities observed in normal individuals

  2. Perineal Ultrasound Findings of Stress Urinary Incontinence : Differentiation from Normal Findings

    International Nuclear Information System (INIS)

    Baek, Seung Yon; Chung, Eun Chul; Rhee, Chung Sik; Suh, Jeong Soo

    1995-01-01

    Perineal ultrasonography is a noninvasive method that is easier than chain cystoure-thrography in the diagnosis of stress urinary incontinence(SUI). We report the findings of stress urinary incontinence at peritoneal ultrasound and its differential points form normal control. Twenty-two patients with SUI and l6 normal controls were included in our study. Aloka SSD 650 with 3.5MHz convex transducer was used, and sagittal image through the bladder, bladder base, urethrovesical junction and pubis was obtained from the vulva area, We measured thepdsterior urethrovesical angle(PUVA) at rest and stress, and calculated the difference between the two angles. We also measured the distance of bladder neck descent during stress and the diameter of proximal urethra at rest. The data were analyzed with student t-test. At rest, PUVA was 135.3 .deg. in patients with SUI group and 134.5 .deg. in normal control group(P=0.8376). During streets, PUVA was 149.5 .deg. in SUI group and 142.1 .deg. in normal group(P=0.0135). The difference PUVAs at rest and during stress was 14.2 .deg. in SUI group and 7.6 .deg. in normal group(P=0.0173). The distance of bladder neck descent during stress was 14.5mm in SUI group and 9.8mm in normal group(P=0.0029). The diameter of proxiaml urethra at rest was 4.4mm in SUI group and 3.6mm in normal group(P=0.0385). In conclusion, ultrasound parameters that include the PUVA during stress, the difference between PUVAs at rest and during stress, the distance of bladder neck descent during stress and the diameter of proximal ureyhra at rest are useful in diagnosis of the stress urinary incontinence

  3. Perineal Ultrasound Findings of Stress Urinary Incontinence : Differentiation from Normal Findings

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Seung Yon; Chung, Eun Chul; Rhee, Chung Sik; Suh, Jeong Soo [Ewha Womans University Hospital, Seoul (Korea, Republic of)

    1995-06-15

    Perineal ultrasonography is a noninvasive method that is easier than chain cystoure-thrography in the diagnosis of stress urinary incontinence(SUI). We report the findings of stress urinary incontinence at peritoneal ultrasound and its differential points form normal control. Twenty-two patients with SUI and l6 normal controls were included in our study. Aloka SSD 650 with 3.5MHz convex transducer was used, and sagittal image through the bladder, bladder base, urethrovesical junction and pubis was obtained from the vulva area, We measured thepdsterior urethrovesical angle(PUVA) at rest and stress, and calculated the difference between the two angles. We also measured the distance of bladder neck descent during stress and the diameter of proximal urethra at rest. The data were analyzed with student t-test. At rest, PUVA was 135.3 .deg. in patients with SUI group and 134.5 .deg. in normal control group(P=0.8376). During streets, PUVA was 149.5 .deg. in SUI group and 142.1 .deg. in normal group(P=0.0135). The difference PUVAs at rest and during stress was 14.2 .deg. in SUI group and 7.6 .deg. in normal group(P=0.0173). The distance of bladder neck descent during stress was 14.5mm in SUI group and 9.8mm in normal group(P=0.0029). The diameter of proxiaml urethra at rest was 4.4mm in SUI group and 3.6mm in normal group(P=0.0385). In conclusion, ultrasound parameters that include the PUVA during stress, the difference between PUVAs at rest and during stress, the distance of bladder neck descent during stress and the diameter of proximal ureyhra at rest are useful in diagnosis of the stress urinary incontinence

  4. Interleaving subthalamic nucleus deep brain stimulation to avoid side effects while achieving satisfactory motor benefits in Parkinson disease: A report of 12 cases.

    Science.gov (United States)

    Zhang, Shizhen; Zhou, Peizhi; Jiang, Shu; Wang, Wei; Li, Peng

    2016-12-01

    Deep brain stimulation (DBS) of the subthalamic nucleus is an effective treatment for advanced Parkinson disease (PD). However, achieving ideal outcomes by conventional programming can be difficult in some patients, resulting in suboptimal control of PD symptoms and stimulation-induced adverse effects. Interleaving stimulation (ILS) is a newer programming technique that can individually optimize the stimulation area, thereby improving control of PD symptoms while alleviating stimulation-induced side effects after conventional programming fails to achieve the desired results. We retrospectively reviewed PD patients who received DBS programming during the previous 4 years in our hospital. We collected clinical and demographic data from 12 patients who received ILS because of incomplete alleviation of PD symptoms or stimulation-induced adverse effects after conventional programming had proven ineffective or intolerable. Appropriate lead location was confirmed with postoperative reconstruction images. The rationale and clinical efficacy of ILS was analyzed. We divided our patients into 4 groups based on the following symptoms: stimulation-induced dysarthria and choreoathetoid dyskinesias, gait disturbance, and incomplete control of parkinsonism. After treatment with ILS, patients showed satisfactory improvement in PD symptoms and alleviation of stimulation-induced side effects, with a mean improvement in Unified PD Rating Scale motor scores of 26.9%. ILS is a newer choice and effective programming strategy to maximize symptom control in PD while decreasing stimulation-induced adverse effects when conventional programming fails to achieve satisfactory outcome. However, we should keep in mind that most DBS patients are routinely treated with conventional stimulation and that not all patients benefit from ILS. ILS is not recommended as the first choice of programming, and it is recommended only when patients have unsatisfactory control of PD symptoms or stimulation

  5. Renal function maturation in children: is normalization to surface area valid?

    International Nuclear Information System (INIS)

    Rutland, M.D.; Hassan, I.M.; Que, L.

    1999-01-01

    Full text: Gamma camera DTPA renograms were analysed to measure renal function by the rate at which the kidneys took up tracer from the blood. This was expressed either directly as the fractional uptake rate (FUR), which is not related to body size, or it was converted to a camera-based GFR by the formula GFR blood volume x FUR, and this GFR was normalized to a body surface area of 1.73 m2. Most of the patients studied had one completely normal kidney, and one kidney with reflux but normal function and no large scars. The completely normal kidneys contributed, on average, 50% of the total renal function. The results were considered in age bands, to display the effect of age on renal function. The camera-GFR measurements showed the conventional results of poor renal function in early childhood, with a slow rise to near-adult values by the age of 2 years, and somewhat low values throughout childhood. The uptake values showed a different pattern, with renal function rising to adult equivalent values by the age of 4 months, and with children having better renal function than adults throughout most of their childhood. The standard deviations expressed as coefficients of variation (CV) were smaller for the FUR technique than the GFR (Wilcoxon rank test, P < 0.01). These results resemble recent published measurements of absolute DMSA uptake, which are also unrelated to body size and show early renal maturation. The results also suggest that the reason children have lower serum creatinine levels than adults is that they have better renal function. If this were confirmed, it would raise doubts about the usefulness of normalizing renal function to body surface area in children

  6. Normalization and gene p-value estimation: issues in microarray data processing.

    Science.gov (United States)

    Fundel, Katrin; Küffner, Robert; Aigner, Thomas; Zimmer, Ralf

    2008-05-28

    Numerous methods exist for basic processing, e.g. normalization, of microarray gene expression data. These methods have an important effect on the final analysis outcome. Therefore, it is crucial to select methods appropriate for a given dataset in order to assure the validity and reliability of expression data analysis. Furthermore, biological interpretation requires expression values for genes, which are often represented by several spots or probe sets on a microarray. How to best integrate spot/probe set values into gene values has so far been a somewhat neglected problem. We present a case study comparing different between-array normalization methods with respect to the identification of differentially expressed genes. Our results show that it is feasible and necessary to use prior knowledge on gene expression measurements to select an adequate normalization method for the given data. Furthermore, we provide evidence that combining spot/probe set p-values into gene p-values for detecting differentially expressed genes has advantages compared to combining expression values for spots/probe sets into gene expression values. The comparison of different methods suggests to use Stouffer's method for this purpose. The study has been conducted on gene expression experiments investigating human joint cartilage samples of osteoarthritis related groups: a cDNA microarray (83 samples, four groups) and an Affymetrix (26 samples, two groups) data set. The apparently straight forward steps of gene expression data analysis, e.g. between-array normalization and detection of differentially regulated genes, can be accomplished by numerous different methods. We analyzed multiple methods and the possible effects and thereby demonstrate the importance of the single decisions taken during data processing. We give guidelines for evaluating normalization outcomes. An overview of these effects via appropriate measures and plots compared to prior knowledge is essential for the biological

  7. Normal patterns of 18F-FDG appendiceal uptake in children

    Energy Technology Data Exchange (ETDEWEB)

    Reavey, Hamilton E. [Emory University, Department of Radiology and Imaging Sciences, Division of Nuclear Medicine Molecular Imaging, Atlanta, GA (United States); Alazraki, Adina L.; Simoneaux, Stephen F. [Emory University, Department of Radiology and Imaging Sciences, Division of Pediatric Imaging, Children' s Healthcare of Atlanta at Egleston, Atlanta, GA (United States)

    2014-04-15

    Prior to interpreting PET/CT, it is crucial to understand the normal biodistribution of fluorodeoxyglucose (FDG). It is also important to realize that the normal biodistribution can vary between adults and children. Although many studies have defined normal patterns of pediatric FDG uptake in structures like the thymus, brown fat and bone marrow, patterns of normal pediatric bowel activity, specifically uptake within the appendix, have not been well described. Active lymphoid tissue has increased FDG uptake when compared with inactive tissue. Since children have more active lymphoid tissue than adults, and because the appendix contains aggregated lymphoid tissue, we postulated that appendiceal uptake may be increased in pediatric patients. To define the normal level of appendiceal FDG activity in children by evaluating a series of consecutive FDG PET/CT scans performed for other indications. After obtaining IRB approval, we retrospectively reviewed 128 consecutive whole-body pediatric FDG PET/CT examinations obtained for a variety of clinical indications. CT scans on which the appendix could not be visualized were excluded from analysis. CT scans on which the appendix could be visualized were evaluated for underlying appendiceal pathology. Studies with appendiceal or periappendiceal pathology by CT criteria were excluded. A region of interest (ROI) was placed over a portion of each appendix and appendiceal maximum standardized uptake value (SUVmax) was calculated. If an adjacent loop of bowel activity interfered with accurate measurements of the appendix SUVmax, the scan was excluded from the analysis. A chart review was performed on patients with elevated appendiceal SUVmax values to ensure that the patients did not have clinical symptomatology suggestive of acute appendicitis. When the appendix or a portion of the appendix could be visualized and accurately measured, the SUVmax was determined. SUVmax of the appendix was compared to the SUVmax of normal liver and

  8. UPLC-MS method for quantification of pterostilbene and its application to comparative study of bioavailability and tissue distribution in normal and Lewis lung carcinoma bearing mice.

    Science.gov (United States)

    Deng, Li; Li, Yongzhi; Zhang, Xinshi; Chen, Bo; Deng, Yulin; Li, Yujuan

    2015-10-10

    A UPLC-MS method was developed for determination of pterostilbene (PTS) in plasma and tissues of mice. PTS was separated on Agilent Zorbax XDB-C18 column (50 × 2.1 mm, 1.8 μm) with gradient mobile phase at the flow rate of 0.2 ml/min. The detection was performed by negative ion electrospray ionization in multiple reaction monitoring mode. The linear calibration curve of PTS in mouse plasma and tissues ranged from 1.0 to 5000 and 0.50 to 500 ng/ml (r(2)>0.9979), respectively, with lowest limits of quantification (LLOQ) were between 0.5 and 2.0 ng/ml, respectively. The accuracy and precision of the assay were satisfactory. The validated method was applied to the study of bioavailability and tissue distribution of PTS in normal and Lewis lung carcinoma (LLC) bearing mice. The bioavailability of PTS (dose 14, 28 and 56 mg/kg) in normal mice were 11.9%, 13.9% and 26.4%, respectively; and the maximum level (82.1 ± 14.2 μg/g) was found in stomach (dose 28 mg/kg). The bioavailability, peak concentration (Cmax), time to peak concentration (Tmax) of PTS in LLC mice was increased compared with normal mice. The results indicated the UPLC-MS method is reliable and bioavailability and tissue distribution of PTS in normal and LLC mice were dramatically different. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. A New Modified Histogram Matching Normalization for Time Series Microarray Analysis.

    Science.gov (United States)

    Astola, Laura; Molenaar, Jaap

    2014-07-01

    Microarray data is often utilized in inferring regulatory networks. Quantile normalization (QN) is a popular method to reduce array-to-array variation. We show that in the context of time series measurements QN may not be the best choice for this task, especially not if the inference is based on continuous time ODE model. We propose an alternative normalization method that is better suited for network inference from time series data.

  10. Online Normalization Algorithm for Engine Turbofan Monitoring

    Science.gov (United States)

    2014-10-02

    Online Normalization Algorithm for Engine Turbofan Monitoring Jérôme Lacaille 1 , Anastasios Bellas 2 1 Snecma, 77550 Moissy-Cramayel, France...understand the behavior of a turbofan engine, one first needs to deal with the variety of data acquisition contexts. Each time a set of measurements is...it auto-adapts itself with piecewise linear models. 1. INTRODUCTION Turbofan engine abnormality diagnosis uses three steps: reduction of

  11. Body fat assessed from body density and estimated from skinfold thickness in normal children and children with cystic fibrosis.

    Science.gov (United States)

    Johnston, J L; Leong, M S; Checkland, E G; Zuberbuhler, P C; Conger, P R; Quinney, H A

    1988-12-01

    Body density and skinfold thickness at four sites were measured in 140 normal boys, 168 normal girls, and 6 boys and 7 girls with cystic fibrosis, all aged 8-14 y. Prediction equations for the normal boys and girls for the estimation of body-fat content from skinfold measurements were derived from linear regression of body density vs the log of the sum of the skinfold thickness. The relationship between body density and the log of the sum of the skinfold measurements differed from normal for the boys and girls with cystic fibrosis because of their high body density even though their large residual volume was corrected for. However the sum of skinfold measurements in the children with cystic fibrosis did not differ from normal. Thus body fat percent of these children with cystic fibrosis was underestimated when calculated from body density and invalid when calculated from skinfold thickness.

  12. Scaling properties of charged particle multiplicity distributions in oxygen induced emulsion interactions at 14.6, 60 and 200 A GeV

    International Nuclear Information System (INIS)

    Adamovich, M.I.; Aggarwal, M.M.; Arora, R.

    1988-12-01

    The multiplicity distributions of shower particles (n s ) are measured in inclusive inelastic oxygen emulsion interactions. Scaling in observed in the normalized variable n s / ave.(n s ) for 14.6, 60 and 200 A GeV. The dependence of ave. (n s ) on the charge flow in the forward direction (Q ZD ) and the distribution of the number of participating projectile protons is examined. The normalized multiplicities as a function of Q ZD seem also to be independent of incident energies. A comparison with the Lund Model Fritiof yields satisfactory agreement. (authors)

  13. Determination of capillary permeability with labeled human albumin

    International Nuclear Information System (INIS)

    Behar, A.; Tournoux, A.; Baillet, J.; Lagrue, G.

    1976-01-01

    We propose a new test for measuring the 'capillary permeability' with labeled albumin, with simpler methods, satisfactory results and good discrimination between normal subjects and pathological patients. In normal subjects, after the removal of the tourniquet, the radioactivity returns to former values (under 10% of this figure). In pathological patients, even after the 3 min following the removal of the tourniquet, there is no return to the former value (the retention of labeled albumin is always over 10%). It is in cycle oedema that the test provides the most interesting results. (orig) [de

  14. Loss of Brain Aerobic Glycolysis in Normal Human Aging.

    Science.gov (United States)

    Goyal, Manu S; Vlassenko, Andrei G; Blazey, Tyler M; Su, Yi; Couture, Lars E; Durbin, Tony J; Bateman, Randall J; Benzinger, Tammie L-S; Morris, John C; Raichle, Marcus E

    2017-08-01

    The normal aging human brain experiences global decreases in metabolism, but whether this affects the topography of brain metabolism is unknown. Here we describe PET-based measurements of brain glucose uptake, oxygen utilization, and blood flow in cognitively normal adults from 20 to 82 years of age. Age-related decreases in brain glucose uptake exceed that of oxygen use, resulting in loss of brain aerobic glycolysis (AG). Whereas the topographies of total brain glucose uptake, oxygen utilization, and blood flow remain largely stable with age, brain AG topography changes significantly. Brain regions with high AG in young adults show the greatest change, as do regions with prolonged developmental transcriptional features (i.e., neoteny). The normal aging human brain thus undergoes characteristic metabolic changes, largely driven by global loss and topographic changes in brain AG. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. IMPROVING QUALITY OF STATISTICAL PROCESS CONTROL BY DEALING WITH NON‐NORMAL DATA IN AUTOMOTIVE INDUSTRY

    Directory of Open Access Journals (Sweden)

    Zuzana ANDRÁSSYOVÁ

    2012-07-01

    Full Text Available Study deals with an analysis of data to the effect that it improves the quality of statistical tools in processes of assembly of automobile seats. Normal distribution of variables is one of inevitable conditions for the analysis, examination, and improvement of the manufacturing processes (f. e.: manufacturing process capability although, there are constantly more approaches to non‐normal data handling. An appropriate probability distribution of measured data is firstly tested by the goodness of fit of empirical distribution with theoretical normal distribution on the basis of hypothesis testing using programme StatGraphics Centurion XV.II. Data are collected from the assembly process of 1st row automobile seats for each characteristic of quality (Safety Regulation ‐S/R individually. Study closely processes the measured data of an airbag´s assembly and it aims to accomplish the normal distributed data and apply it the statistical process control. Results of the contribution conclude in a statement of rejection of the null hypothesis (measured variables do not follow the normal distribution therefore it is necessary to begin to work on data transformation supported by Minitab15. Even this approach does not reach a normal distributed data and so should be proposed a procedure that leads to the quality output of whole statistical control of manufacturing processes.

  16. COBE DMR-normalized open inflation cold dark matter cosmogony

    Science.gov (United States)

    Gorski, Krzysztof M.; Ratra, Bharat; Sugiyama, Naoshi; Banday, Anthony J.

    1995-01-01

    A cut-sky orthogonal mode analysis of the 2 year COBE DMR 53 and 90 GHz sky maps (in Galactic coordinates) is used to determine the normalization of an open inflation model based on the cold dark matter (CDM) scenario. The normalized model is compared to measures of large-scale structure in the universe. Although the DMR data alone does not provide sufficient discriminative power to prefer a particular value of the mass density parameter, the open model appears to be reasonably consistent with observations when Omega(sub 0) is approximately 0.3-0.4 and merits further study.

  17. Currents, HF Radio-derived, Ano Nuevo, Normal Model, Meridional, EXPERIMENTAL

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data is the meridional component of ocean surface currents derived from High Frequency Radio-derived measurements, with missing values filled in by a normal...

  18. Currents, HF Radio-derived, Monterey Bay, Normal Model, Meridional, EXPERIMENTAL

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data is the meridional component of ocean surface currents derived from High Frequency Radio-derived measurements, with missing values filled in by a normal...

  19. MR measurement of normal corpus callosum: Age and sex differentiation

    International Nuclear Information System (INIS)

    Lee, Myung Seob; Kim, Myung Soon; Park, Hyun Ju

    1992-01-01

    Measurement of various portions of the corpus callosum was performed on magnetic resonance(MR) images of 114 subjects with no known or suspected corpus callosal disorders. Midsagittal T1-weighted images used for measurements and mean diameters of various portions in each age and sex group were obtained. Measures of five portions were made: (A) the anterio-posterior length, (B) the diameter of genu position, (C) the diameter of splenium, (D) the diameter of mid-body portion, (E) the diameter of a narrow portion at the body of corpus callosum. The mean diameter in each gender group for A, B, C, D and E were 68.8 mm, 12.1 mm, 12.3 mm, 6,9 mm, 4.1 mm in male and 69.9 mm, 12.0 mm, 12.1 mm, 6.4 mm, 4.1 mm in female, retrospectively. The groups of 0-9 years of both genders showed the minimum mean value in each portion

  20. MR measurement of normal corpus callosum: Age and sex differentiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Seob; Kim, Myung Soon; Park, Hyun Ju [Wonju College of Medicine, Yonsei University, Wonju (Korea, Republic of)

    1992-07-15

    Measurement of various portions of the corpus callosum was performed on magnetic resonance(MR) images of 114 subjects with no known or suspected corpus callosal disorders. Midsagittal T1-weighted images used for measurements and mean diameters of various portions in each age and sex group were obtained. Measures of five portions were made: (A) the anterio-posterior length, (B) the diameter of genu position, (C) the diameter of splenium, (D) the diameter of mid-body portion, (E) the diameter of a narrow portion at the body of corpus callosum. The mean diameter in each gender group for A, B, C, D and E were 68.8 mm, 12.1 mm, 12.3 mm, 6,9 mm, 4.1 mm in male and 69.9 mm, 12.0 mm, 12.1 mm, 6.4 mm, 4.1 mm in female, retrospectively. The groups of 0-9 years of both genders showed the minimum mean value in each portion.