WorldWideScience

Sample records for normal liquid level

  1. Neutron scattering by normal liquids

    Energy Technology Data Exchange (ETDEWEB)

    Gennes, P.G. de [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    Neutron data on motions in normal liquids well below critical point are reviewed and classified according to the order of magnitude of momentum transfers {Dirac_h}q and energy transfers {Dirac_h}w. For large momentum transfers a perfect gas model is valid. For smaller q and incoherent scattering, the major effects are related to the existence of two characteristic times: the period of oscillation of an atom in its cell, and the average lifetime of the atom in a definite cell. Various interpolation schemes covering both time scales are discussed. For coherent scattering and intermediate q, the energy spread is expected to show a minimum whenever q corresponds to a diffraction peak. For very small q the standard macroscopic description of density fluctuations is applicable. The limits of the various (q) and (w) domains and the validity of various approximations are discussed by a method of moments. The possibility of observing discrete transitions due to internal degrees of freedom in polyatomic molecules, in spite of the 'Doppler width' caused by translational motions, is also examined. (author) [French] L'auteur examine les donnees neutroniques sur les mouvements dans les liquides normaux, bien au-dessous du point critique, et les classe d'apres l'ordre de grandeur des transferts de quantite de mouvement {Dirac_h}q et des transferts d'energie {Dirac_h}w. Pour les grands transferts de, quantite de mouvement, un modele de gaz parfait est valable. En ce qui concerne les faibles valeurs de q et la diffussion incoherente, les principaux effets sont lies a l'existence de deux temps caracteristiques: la periode d'oscillation d'un atome dans sa cellule et la duree moyenne de vie de l'atome dans une cellule determinee. L'auteur etudie divers systemes d'interpolation se rapportant aux deux echelles de temps. Pour la diffusion coherente et les valeurs intermediaires de q, on presume que le spectre d'energie accuse un minimum chaque fois que q correspond a un pic de

  2. PEP liquid level system

    International Nuclear Information System (INIS)

    Lauritzen, T.; Sah, R.C.

    1981-03-01

    A liquid level system has been installed in the accelerator housing of the PEP storage ring. This instrument spans the entire 2.2 km circumference of the PEP project, and over one hundred readouts provide reference elevations which are used for the accurate alignment of accelerator components. The liquid level has proven to be extremely precise (+-0.10 mm) and quick to use, and it has contributed to the accurate alignment of PEP before beam turn-on. Since the liquid level readouts are rigidly attached to the accelerator housing, the liquid level has been a convenient means to monitor the settling of the accelerator housing

  3. Liquid level controller

    International Nuclear Information System (INIS)

    Mangus, J.D.; Redding, A.H.

    1975-01-01

    A system for maintaining two distinct sodium levels within the shell of a heat exchanger having a plurality of J-shaped modular tube bundles each enclosed in a separate shell which extends from a common base portion. A lower liquid level is maintained in the base portion and an upper liquid level is maintained in the shell enwrapping the long stem of the J-shaped tube bundles by utilizing standpipes with a notch at the lower end which decreases in open area the distance from the end of the stand pipe increases and a supply of inert gas fed at a constant rate to produce liquid levels, which will remain generally constant as the flow of liquid through the vessel varies

  4. Liquid metal level measurement

    International Nuclear Information System (INIS)

    Hale, J.C.; Leyland, K.S.

    1982-01-01

    A liquid metal level indicator is described which can be used to measure, in a stainless steel tank, the level of a nuclear reactor coolant such as sodium. The instrument, which is based on the eddy current induction effect, gives readings over substantially the full depth of the tank and indicates the sense of change of level. (U.K.)

  5. Liquid Level Sensing System

    Science.gov (United States)

    Korman, Valentin (Inventor); Wiley, John T. (Inventor); Duffell, Amanda G. (Inventor)

    2014-01-01

    A liquid level sensing system includes waveguides disposed in a liquid and distributed along a path with a gap between adjacent waveguides. A source introduces electromagnetic energy into the waveguides at a first end of the path. A portion of the electromagnetic energy exits the waveguides at a second end of the path. A detector measures the portion of the electromagnetic energy exiting the second end of the path.

  6. Liquid level detector

    International Nuclear Information System (INIS)

    Dean, A.P.; Pendleton, J.R.

    1982-01-01

    A device is described for locating the level of the liquid metal in a sodium cooled nuclear reactor by using a movable probe equipped to signal a phase change with null on arrival at the interface between two conductively differing media. (U.K.)

  7. Microscopic theory of normal liquid 3He

    International Nuclear Information System (INIS)

    Nafari, N.; Doroudi, A.

    1994-03-01

    We have used the self-consistent scheme proposed by Singwi, Tosi, Land and Sjoelander (STLS) to study the properties of normal liquid 3 He. By employing the Aziz potential (HFD-B) and some other realistic pairwise interactions, we have calculated the static structure factor, the pair-correlation function, the zero sound frequencies as a function of wave-vector, and the Landau parameter F s 0 for different densities. Our results show considerable improvement over the Ng-Singwi's model potential of a hard core plus an attractive tail. Agreement between our results and the experimental data for the static structure factor and the zero sound frequencies is fairly good. (author). 30 refs, 6 figs, 2 tabs

  8. Hemoglobin levels in normal Filipino pregnant women.

    Science.gov (United States)

    Kuizon, M D; Natera, M G; Ancheta, L P; Platon, T P; Reyes, G D; Macapinlac, M P

    1981-09-01

    The hemoglobin concentrations during pregnancy in Filipinos belonging to the upper income group, who were prescribed 105 mg elemental iron daily, and who had acceptable levels of transferrin saturation, were examined in an attempt to define normal levels. The hemoglobin concentrations for each trimester followed a Gaussian distribution. The hemoglobin values equal to the mean minus one standard deviation were 11.4 gm/dl for the first trimester and 10.4 gm/dl for the second and third trimesters. Using these values as the lower limits of normal, in one group of pregnant women the prevalence of anemia during the last two trimesters was found lower than that obtained when WHO levels for normal were used. Groups of women with hemoglobin of 10.4 to 10.9 gm/dl (classified anemic by WHO criteria but normal in the present study) and those with 11.0 gm/dl and above could not be distinguished on the basis of their serum ferritin levels nor on the degree of decrease in their hemoglobin concentration during pregnancy. Many subjects in both groups, however, had serum ferritin levels less than 12 ng/ml which indicate poor iron stores. It might be desirable in future studies to determine the hemoglobin cut-off point that will delineate subjects who are both non-anemic and adequate in iron stores using serum ferritin levels as criterion for the latter.

  9. Liquid level control system for vapour generator

    International Nuclear Information System (INIS)

    Singh, G.

    1984-01-01

    A system for regulating the liquid level in a vapor generator, in which the incoming flow of feed liquid is regulated in response to the difference between the measured liquid level and a reference level, the difference between the exiting vapor mass flow rate and the incoming liquid mass flow rate, and a function of the measured incoming liquid temperature. The temperature function produces a gain value, which increases in response to decreasing incoming liquid temperature. The purpose of the temperature function is to stabilize the level control under transient conditions (e.g. sudden lose of load). (author)

  10. Improved Root Normal Size Distributions for Liquid Atomization

    Science.gov (United States)

    2015-11-01

    ANSI Std. Z39.18 j CONVERSION TABLE Conversion Factors for U.S. Customary to metric (SI) units of measurement. MULTIPLY BY TO...Gray (Gy) coulomb /kilogram (C/kg) second (s) kilogram (kg) kilo pascal (kPa) 1 Improved Root Normal Size Distributions for Liquid

  11. Fluorescent optical liquid-level sensor

    International Nuclear Information System (INIS)

    Weiss, Jonathan D.

    2000-01-01

    An optical method of detecting a liquid level is presented that uses fluorescence radiation generated in an impurity-doped glass or plastic slab. In operation, the slab is inserted into the liquid and pump light is coupled into it so that the light is guided by the slab-air interface above the liquid and escapes into the liquid just below its surface. Since the fluorescence is generated only in that section of the slab above the liquid, the fluorescence power will monotonically decrease with increasing liquid level. Thus, a relationship can be established between any signal proportional to it and the liquid level. Because optical fibers link the pump source and the detector of fluorescence radiation to the sensor, no electrical connections are needed in or near the liquid. Their absence vastly decreases the hazard associated with placing a liquid-level sensor in a potentially explosive environment. A laboratory prototype, consisting of a methyl styrene slab doped with an organic dye, has been built and successfully tested in water. Its response to liquid level when pumped by a tunable argon-ion laser at 476, 488, and 496 nm, and by a blue LED, is presented and shown to be consistent with theory. The fluorescence spectra, optical efficiency, temperature, and other effects are also presented and discussed. (c) 2000 Society of Photo-Optical Instrumentation Engineers

  12. Liquid level measurement in high level nuclear waste slurries

    International Nuclear Information System (INIS)

    Weeks, G.E.; Heckendorn, F.M.; Postles, R.L.

    1990-01-01

    Accurate liquid level measurement has been a difficult problem to solve for the Defense Waste Processing Facility (DWPF). The nuclear waste sludge tends to plug or degrade most commercially available liquid-level measurement sensors. A liquid-level measurement system that meets demanding accuracy requirements for the DWPF has been developed. The system uses a pneumatic 1:1 pressure repeater as a sensor and a computerized error correction system. 2 figs

  13. About the principles of radiation level normalization

    International Nuclear Information System (INIS)

    Nosovskij, A.V.

    2000-01-01

    The paper highlights the impact being made by the radiation level normalization principles upon the social and economic indicators. The newly introduced radiation safety standards - 97 are taken as an example. It is emphasized that it is necessary to use a sound approach while defining radiation protection standards, taking into consideration economic and social factors existing in Ukraine at the moment. Based on the concept of the natural radiation background and available results of the epidemiological surveys, the dose limits are proposed for the radiation protection standards. The paper gives a description of the dose limitation system recommended by the International Committee for Radiation Protection. The paper highlights a negative impact of the line non threshold concept, lack of special knowledge in the medical service and mass media to make decisions to protect people who suffered from the Chernobyl accident

  14. The thermodynamic properties of normal liquid helium 3

    Science.gov (United States)

    Modarres, M.; Moshfegh, H. R.

    2009-09-01

    The thermodynamic properties of normal liquid helium 3 are calculated by using the lowest order constrained variational (LOCV) method. The Landau Fermi liquid model and Fermi-Dirac distribution function are considered as our statistical model for the uncorrelated quantum fluid picture and the Lennard-Jones and Aziz potentials are used in our truncated cluster expansion (LOCV) to calculate the correlated energy. The single particle energy is treated variationally through an effective mass. The free energy, pressure, entropy, chemical potential and liquid phase diagram as well as the helium 3 specific heat are evaluated, discussed and compared with the corresponding available experimental data. It is found that the critical temperature for the existence of the pure gas phase is about 4.90 K (4.45 K), which is higher than the experimental prediction of 3.3 K, and the helium 3 flashing temperature is around 0.61 K (0.50 K) for the Lennard-Jones (Aziz) potential.

  15. Transport and magnetic resonance in normal and superfluid Fermi liquids

    International Nuclear Information System (INIS)

    Smith, H.

    1976-10-01

    This thesis provides a framework for a series of 19 papers published by the author in a study of transport and magnetic resonance in normal and superfluid Fermi liquids. The Boltzmann equation and methods for its solution are discussed. Electron-electron scattering in metals, with particular emphasis on alkali metals, is considered. Transport in a normal uncharged Fermi liquid such as pure 3 He at temperatures well below its degeneracy temperature of approximately 1 K or mixtures of 3 He in 4 He with degeneracy temperatures ranging typically from 100 to 200 mk is discussed with emphasis on comparison with experiments with the aim of testing models of the particle-particle scattering amplitude. Transport and magnetic resonance in superfluid 3 He is considered. The phenomenological treatment of relaxation is reviewed and the magnitude of the phenomenlogical relaxation time close to Tsub(c) is derived for the case of longitudinal resonance. Comments are made on non-linear magnetic resonance and textures and spin waves. (B.R.H.)

  16. Non-contact optical Liquid Level Sensors

    Science.gov (United States)

    Kiseleva, L. L.; Tevelev, L. V.; Shaimukhametov, R. R.

    2016-06-01

    Information about characteristics of the optical liquid level sensor are present. Sensors are used to control of the light level limit fluid - water, kerosene, alcohol, solutions, etc. Intrinsically safe, reliable and easy to use. The operating principle of the level sensor is an optoelectronic infrared device.

  17. A high Tc superconducting liquid nitrogen level sensor

    International Nuclear Information System (INIS)

    Jin, J. X.; Liu, H. K.; Dou, S. X.; Grantham, C.; Beer, J.

    1996-01-01

    Full text: The dramatic resistance change in the superconducting-normal transition temperature range enables a high T c superconductor to be considered for designing a liquid nitrogen level sensor. A (Bi,Pb) 2 Sr 2 Ca 2 Cu 3 O 10+x Ag clad superconducting wire is selected and tested as a continuous liquid nitrogen level sensor to investigate the possibility for this application. The (Bi,Pb) 2 Sr 2 Ca 2 Cu 3 O 10+x Ag clad superconducting wire has approximately 110 K critical temperature, with more flexible and stable properties compared with bulk shape ceramic high T c superconductors. The voltage drops across the sensor are tested with different immersion lengths in liquid nitrogen. The accuracy of the HTS sensor is analysed with its dR/dT in the superconducting-normal transition range. The voltage signal is sensitive to liquid nitrogen level change, and this signal can be optimized by controlling the transport current. The problems of the Ag clad superconductor are that the Ag sheath thermal conductivity is very high, and the sensor normal resistance is low. These are the main disadvantages for using such a wire as a continuous level sensor. However, a satisfactory accuracy can be achieved by control of the transport current. A different configuration of the wire sensor is also designed to avoid this thermal influence

  18. Treatment of low- and intermediate-level liquid radioactive wastes

    International Nuclear Information System (INIS)

    1984-01-01

    This report aims at giving the reader details of the experience gained in the treatment of both low- and intermediate-level radioactive liquid wastes. The treatment comprises those operations to remove radioactivity from the wastes and those that change only its chemical composition, so as to permit its discharge. Considerable experience has been accumulated in the satisfactory treatment of such wastes. Although there are no universally accepted definitions for low- and intermediate-level liquid radioactive wastes, the IAEA classification (see section 3.2) is used in this report. The two categories differ from one another in the fact that for low-level liquids the actual radiation does not require shielding during normal handling of the wastes. Liquid wastes which are not considered in this report are those from mining and milling operations and the high-level liquid wastes resulting from fuel reprocessing. These are referred to in separate IAEA reports. Likewise, wastes from decommissioning operations are not within the scope of this report. Apart from the description of existing methods and facilities, this report is intended to provide advice to the reader for the selection of appropriate solutions to waste management problems. In addition, new and promising techniques which are either being investigated or being considered for the future are discussed

  19. Applications of low level liquid scintillation counting

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1983-01-01

    Low level liquid scintillation counting is reviewed in terms of its present use and capabilities for measuring low activity samples. New areas of application of the method are discussed with special interest directed to the food industry and environmental monitoring. Advantages offered in the use of a low background liquid scintillation counter for the nuclear power industry and nuclear navy are discussed. Attention is drawn to the need for commercial development of such instrumentation to enable wider use of the method. A user clientele is suggested as is the required technology to create such a counter

  20. Liquid low level waste management expert system

    International Nuclear Information System (INIS)

    Ferrada, J.J.; Abraham, T.J.; Jackson, J.R.

    1991-01-01

    An expert system has been developed as part of a new initiative for the Oak Ridge National Laboratory (ORNL) systems analysis program. This expert system will aid in prioritizing radioactive waste streams for treatment and disposal by evaluating the severity and treatability of the problem, as well as the final waste form. The objectives of the expert system development included: (1) collecting information on process treatment technologies for liquid low-level waste (LLLW) that can be incorporated in the knowledge base of the expert system, and (2) producing a prototype that suggests processes and disposal technologies for the ORNL LLLW system. 4 refs., 9 figs

  1. Bartter Syndrome with Normal Aldosterone Level: An Unusual Presentation.

    Science.gov (United States)

    Huque, S S; Rahman, M H; Khatun, S

    2016-04-01

    Bartter syndrome (BS) is a hereditary disease, with an autosomal recessive or autosomal dominant mode of transmission. It is characterized by salt wasting hypochloraemic, hypokalaemic metabolic alkalosis and hyperreninaemia with normal blood pressure. The primary defect is in the thick ascending limb of loop of Henle (TAL). Herein, we report a case that had typical features of BS like severe dehydration, severe hypokalaemia, metabolic alkalosis and failure to thrive but had normal aldosterone level which is very uncommon.

  2. Instructions for 104-SX liquid level measurement field tests

    International Nuclear Information System (INIS)

    Webb, R.H.

    1994-01-01

    This document provides detailed instructions for field testing a suggested solution of inserting a liner inside the 104-SX failed Liquid Observation Well to gain access for making temporary Liquid Level Measurement until a permanent solution has been provided

  3. Expert system for liquid low-level waste management

    International Nuclear Information System (INIS)

    Ferrada, J.J.

    1992-01-01

    An expert system prototype has been developed to support system analysis activities at the Oak Ridge National Laboratory (ORNL) for waste management tasks. This expert system will aid in prioritizing radioactive waste streams for treatment and disposal by evaluating the severity and treatability of the problem as well as the final waste form. The objectives of the expert system development included: (1) collecting information on process treatment technologies for liquid low-level waste (LLLW) that can be incorporated in the knowledge base of the expert system, and (2) producing a prototype that suggests processes and disposal technologies for the ORNL LLLW system. The concept under which the expert system has been designed is integration of knowledge. There are many sources of knowledge (data bases, text files, simulation programs, etc.) that an expert would regularly consult in order to solve a problem of liquid waste management. The expert would normally know how to extract the information from these different sources of knowledge. The general scope of this project would be to include as much pertinent information as possible within the boundaries of the expert system. As a result, the user, who may not be an expert in every aspect of liquid waste management, may be able to apply the content of the information to a specific waste problem. This paper gives the methodological steps to develop the expert system under this general framework

  4. NORMAL NASAL GENE EXPRESSION LEVELS USING CDNA ARRAY TECHNOLOGY

    Science.gov (United States)

    Normal Nasal Gene Expression Levels Using cDNA Array Technology. The nasal epithelium is a target site for chemically-induced toxicity and carcinogenicity. To detect and analyze genetic events which contribute to nasal tumor development, we first defined the gene expressi...

  5. Vitrification of high-level liquid wastes

    International Nuclear Information System (INIS)

    Varani, J.L.; Petraitis, E.J.; Vazquez, Antonio.

    1987-01-01

    High-level radioactive liquid wastes produced in the fuel elements reprocessing require, for their disposal, a preliminary treatment by which, through a series of engineering barriers, the dispersion into the biosphere is delayed by 10 000 years. Four groups of compounds are distinguished among a great variety of final products and methods of elaboration. From these, the borosilicate glasses were chosen. Vitrification experiences were made at a laboratory scale with simulated radioactive wastes, employing different compositions of borosilicate glass. The installations are described. A series of tests were carried out on four basic formulae using always the same methodology, consisting of a dry mixture of the vitreous matrix's products and a dry simulated mixture. Several quality tests of the glasses were made 1: Behaviour in leaching following the DIN 12 111 standard; 2: Mechanical resistance; parameters related with the facility of the different glasses for increasing their surface were studied; 3: Degree of devitrification: it is shown that devitrification turns the glasses containing radioactive wastes easily leachable. From all the glasses tested, the composition SiO 2 , Al 2 O 3 , B 2 O 3 , Na 2 O, CaO shows the best retention characteristics. (M.E.L.) [es

  6. Radiation exposure rate and liquid level measurement inside a high level liquid waste (HLLW) storage tank

    International Nuclear Information System (INIS)

    Sur, B.; Yue, S.; Thekkevarriam, A.

    2007-01-01

    An instrument based on an inexpensive, small silicon diode has been developed and used to measure, for the first time, the gamma radiation exposure rate profile inside a 6.4 mm diameter reentrant thermo-well tube, immersed in the highly radioactive liquid solution in an HLLW storage tank. The measurement agrees with previous calculations of exposure rate, and provides confirmation for safe and effective radiation work plans and material selection for investigations and remediation of the storage tank facility. The measured radiation exposure rate profile is also used to confirm that the position of tank internal structures have not changed because of aging and corrosion, and to obtain, within a few mm, the level of liquid inside the tank. (author)

  7. Fluorescence Spectrum and Decay Measurement for Hsil VS Normal Cytology Differentiation in Liquid Pap Smear Supernatant

    Science.gov (United States)

    Vaitkuviene, A.; Gegzna, V.; Juodkazis, S.; Jursenas, S.; Miasojedovas, S.; Kurtinaitiene, R.; Rimiene, J.; Vaitkus, J.

    2009-06-01

    Cervical smear material contains endo and exocervical cells, mucus and inflammative, immune cells in cases of pathology. Just not destroyed keratinocytes lay on the glass for microscopy. Liquid cytology supernatant apart other diagnostics could be used for photodiagnostic. The spectroscopic parameters suitable for Normal and HSIL cytology groups supernatant differentiation are demonstrated. The dried liquid PAP supernatant fractions—sediment and liquid were investigated. Excitation and emission matrices (EEM), supernatant fluorescence decay measured under 280 nm diode short pulse excitation and fluorescence spectroscopy by excitation with 355 nm laser light were analyzed. The differences between Normal and HSIL groups were statistically proven in the certain spectral regions. Fluorescence decay peculiarities show spectral regions consisting of few fluorophores. Obtained results on fluorescence differences in Normal and HSIL groups' supernatant shows the potency of photodiagnosis application in cervical screening.

  8. Method of processing low-level radioactive liquid wastes

    International Nuclear Information System (INIS)

    Matsunaga, Ichiro; Sugai, Hiroshi.

    1984-01-01

    Purpose: To effectively reduce the radioactivity density of low-level radioactive liquid wastes discharged from enriched uranium conversion processing steps or the likes. Method: Hydrazin is added to low-level radioactive liquid wastes, which are in contact with iron hydroxide-cation exchange resins prepared by processing strongly acidic-cation exchange resins with ferric chloride and aqueous ammonia to form hydrorizates of ferric ions in the resin. Hydrazine added herein may be any of hydrazine hydrate, hydrazine hydrochloride and hydranine sulfate. The preferred addition amount is more than 100 mg per one liter of the liquid wastes. If it is less than 100 mg, the reduction rate for the radioactivety density (procession liquid density/original liquid density) is decreased. This method enables to effectively reduce the radioactivity density of the low-level radioactive liquid wastes containing a trace amount of radioactive nucleides. (Yoshihara, H.)

  9. Circulating Levels of Irisin in Hypopituitary and Normal Subjects.

    Directory of Open Access Journals (Sweden)

    Lara Pena-Bello

    Full Text Available The recently identified myokine irisin conveys some of the benefits of exercise. Hypopituitarism with adult growth hormone deficiency (HP is a situation characterized by decreased GH secretion and an altered body composition.Our aim was to study the skeletal muscle hormone irisin in HP, and compare the results with a similar group of normal subjects.Seventeen HP patients and fifty-one normal subjects of similar age and sex were studied. The diagnosis of GH deficiency was confirmed by the presence of pituitary disease and a peak GH secretion below 3 μg/L after an insulin tolerance test. The patients were adequately treated for all pituitary hormone deficits, except for GH. Fasting serum irisin was measured with an enzyme immunoassay, and HOMA-IR, QUICKI and HOMA-β were calculated.Fasting irisin levels (ng/ml were similar in normal [208.42 (168.44-249.23] and HP patients [195.13 (178.44-241.44]. In the control group there were moderate significant positive correlations between irisin and BMI, waist circumference, leptin, fasting insulin, HOMA-IR, HOMA-β, triglycerides, and cholesterol. In the control group there were moderate significant negative correlations between irisin and IGF-I and QUICKI. In the hypopituitary group there were moderate significant positive correlations between irisin and body fat and HOMA-β.We found similar irisin levels in GH deficiency hypopituitary patients when compared with normal subjects. The correlation between irisin and adiposity related factors suggests that that in the case of this clinical model, irisin is regulated by adiposity and not by GH.

  10. Cold neutron production in liquid para- and normal-H sub 2 moderators

    CERN Document Server

    Morishima, N

    2002-01-01

    A neutron transport analysis is performed for liquid H sub 2 moderators with 100% para and normal (ortho:para=0.75:0.25) fractions. Four sets of energy-averaged cross-sections (group constants) for liquid ortho- and para-H sub 2 at melting and boiling points are generated and neutron energy range between 0.1 mu eV and 10 eV is broken into 80 groups. Basic moderating characteristics are studied of a model cold-neutron source in a one-dimensional bare-slab geometry. It is shown that liquid para-H sub 2 is superior in cold neutron production to liquid normal H sub 2 on account of a para-to-ortho transition (molecular rotational excitation) and a good transmission property with a mean free path of about 10 cm. In the case of neutron extraction from the inside of the source, high intensity of cold neutrons is possible with liquid normal H sub 2 at higher temperatures up to the boiling point.

  11. Serum gastrin level in pregnancy running a normal course

    Energy Technology Data Exchange (ETDEWEB)

    Milev, N; Todorov, G; Pumpalov, A; Ignatov, A [Meditsinska Akademiya, Sofia (Bulgaria). Nauchen Inst. po Rentgenologiya i Radiobiologiya

    1982-01-01

    The serum gastrin level (SGL) is studied in dynamics during each lunar month of pregnancy in order to accumulate data which may serve the purpose of a tentative standard for serum gastrin level in this peculiar physiologic condition. A group of 110 pregnant women with a normal development of pregnancy, as documented by the clinical and paraclinical examination, are covered by the study. Blood samples are taken before meal, and a radioimmunologic method is used for SGL assessment. The number of women analyzed and the mean age by lunar months are shown. The normal value established in nonpregnant women of the same age group is 28+-7 mg/ml, relative to which the average values during the first five i.m. do not show statistically significant differences. During the 6th l.m. SGL increases to 68.5 mg/ml, while after the 7th l.m. values are recorded exceeding 1aa mg/ml with a maximum observed in the 8th and 9th l.m. The mechanisms eventually involved in the occurrence of gastrinemia during the second half of pregnancy are discussed, e.g. 1/mechanical compression of the stomach by the progressively growing uterus, 2/decreased breakdown, inhibition and elimimation of the hormone by the kidneys, and 3/possible correlative dependence between changes in SGL and changes in the level of hormones playing a predominant role in the hormonal status after the fifth month of pregnancy.

  12. Study on radioactive release of gaseous and liquid effluents during normal operation of AP1000

    International Nuclear Information System (INIS)

    Gong Quan; Zhou Jing; Liu Yu

    2014-01-01

    The gaseous and liquid radioactive releases of pressurized water reactors plant during normal operation are an important content of environmental impact assessment and play a significant role in the design of nuclear power plant. According to the design characters of AP1OOO radioactive waste management system and the study on the calculation method and the release pathways, the calculation model of the gaseous and liquid radioactive releases during normal operation for AP1OOO are established. Base on the established calculation model and the design parameters of AP1000, the expected value of gaseous and liquid radioactive releases of AP1OOO is calculated. The results of calculation are compared with the limits in GB 6249-2011 and explain the adder that is included tu account for anticipated operational occurrences, providing a reference for environmental impact assessment of pressurized water reactor. (authors)

  13. LOFT liquid level transducer application techniques and measurement uncertainty

    International Nuclear Information System (INIS)

    Batt, D.L.; Biladeau, G.L.; Goodrich, L.D.; Nightingale, C.M.

    1979-01-01

    A conductivity sensitive liquid level transducer (LLT) has been designed and used successfully for determining whether steam or water is present in the Loss-of-Fluid Tests (LOFT) performed by EG and G Idaho, Inc., at the Idaho National Engineering Laboratory. The presence of steam or water is determined by establishing a discriminator level which is set manually. A computer program establishes the presence or absence of water for each data point taken. In addition to liquid level, the LLT is used for reactor vessel mass and volume calculations. The uncertainty in the liquid level is essentially the spacing of the LLT electrodes

  14. Study of plasma adrenomedullin level in normal pregnancy and preclampsia.

    Science.gov (United States)

    Senna, Azza Abo; Zedan, Magda; el-Salam, Gamal E Abd; el-Mashad, Ashraf I

    2008-02-06

    The aim of this study was to evaluate whether maternal circulating adrenomedullin (AM) values in patients with preeclampsia are different from those in normotensive pregnant women at different gestational ages. In a prospective clinical study, 90 women aged 17 to 40 years old, were divided into 4 main groups: group I (45 women): Normotensive pregnant women at first trimester (15 women), second trimester (15 women), and third trimester (15 women) of pregnancies. Group II (15 women): Pregnant women with preeclampsia at 25 to 38 weeks of gestation. Group III (15 women): Normotensive healthy nonpregnant women. Group IV (15 women): Hypertensive nonpregnant women. The plasma AM concentration was measured in all women by using enzyme immunoassay kits. Plasma AM levels in pregnant women with normal blood pressure at different gestational ages (first, second, and third trimesters) were statistically significantly higher than those detected in nonpregnant normotensive women and significantly increased with increasing gestational age (P < .001). Moreover, there was significant positive correlation between plasma AM levels and increasing gestational age (r = 0.915, P < .001). Preeclamptic patients had the highest mean plasma AM levels compared with all other groups, which is statistically significant (P < .001) and there was a significant positive correlation between plasma AM levels and systolic blood pressure, diastolic blood pressure, severity of preeclampsia, and proteinuria in pregnant patients with preeclampsia. Maternal plasma AM concentration increases throughout pregnancy and increases as gestational age progresses. AM production starts very early in gestation, suggesting that it may have an important role in human reproduction, from implantation to delivery. Maternal plasma AM level in preeclampsia appears to be higher than that in normal pregnancy.

  15. Ultrasonic level indicator for liquids and its application

    International Nuclear Information System (INIS)

    Kanngiesser, P.

    1976-01-01

    Ultrasonic level indicator for liquids where a piezo-element is used to reverse the piezoelectric effect may be applied in a more versatile way if the indicator is provided with a reflector. It becomes less susceptible to faults and may be used for all liquids, including liquid metals. The piezo-element may then be used at the same time as receiver for ultrasonic waves emitted previously and, in that case, echoed back by the refelctor. (UWI) [de

  16. Liquid hydrogen transfer pipes and level regulation systems

    International Nuclear Information System (INIS)

    Marquet, M.; Prugne, P.; Roubeau, P.

    1961-01-01

    Describes: 1) Transfer pipes - Plunging rods in liquid hydrogen Dewars; transfer pipes: knee-joint system for quick and accurate positioning of plunging Dewar rods; system's rods: combined valve and rod; valves are activated either by a bulb pressure or by a solenoid automatically or hand controlled. The latter allows intermittent filling. 2) Level regulating systems: Level bulbs: accurate to 1 or 4 m; maximum and minimum level bulbs: automatic control of the liquid hydrogen valve. (author) [fr

  17. Light Path Model of Fiber Optic Liquid Level Sensor Considering Residual Liquid Film on the Wall

    Directory of Open Access Journals (Sweden)

    Zhijun Zhang

    2015-01-01

    Full Text Available The working principle of the refractive-type fiber optic liquid level sensor is analyzed in detail based on the light refraction principle. The optic path models are developed in consideration of common simplification and the residual liquid film on the glass tube wall. The calculating formulae for the model are derived, constraint conditions are obtained, influencing factors are discussed, and the scopes and skills of application are analyzed through instance simulations. The research results are useful in directing the correct usage of the fiber optic liquid level sensor, especially in special cases, such as those involving viscous liquid in the glass tube monitoring.

  18. Normalization at the field level: fractional counting of citations

    OpenAIRE

    Leydesdorff, Loet; Opthof, Tobias

    2010-01-01

    Van Raan et al. (2010; arXiv:1003.2113) have proposed a new indicator (MNCS) for field normalization. Since field normalization is also used in the Leiden Rankings of universities, we elaborate our critique of journal normalization in Opthof & Leydesdorff (2010; arXiv:1002.2769) in this rejoinder concerning field normalization. Fractional citation counting thoroughly solves the issue of normalization for differences in citation behavior among fields. This indicator can also be used to obtain ...

  19. Conjugate gradient filtering of instantaneous normal modes, saddles on the energy landscape, and diffusion in liquids.

    Science.gov (United States)

    Chowdhary, J; Keyes, T

    2002-02-01

    Instantaneous normal modes (INM's) are calculated during a conjugate-gradient (CG) descent of the potential energy landscape, starting from an equilibrium configuration of a liquid or crystal. A small number (approximately equal to 4) of CG steps removes all the Im-omega modes in the crystal and leaves the liquid with diffusive Im-omega which accurately represent the self-diffusion constant D. Conjugate gradient filtering appears to be a promising method, applicable to any system, of obtaining diffusive modes and facilitating INM theory of D. The relation of the CG-step dependent INM quantities to the landscape and its saddles is discussed.

  20. Electronic circuit provides automatic level control for liquid nitrogen traps

    Science.gov (United States)

    Turvy, R. R.

    1968-01-01

    Electronic circuit, based on the principle of increased thermistor resistance corresponding to decreases in temperature provides an automatic level control for liquid nitrogen cold traps. The electronically controlled apparatus is practically service-free, requiring only occasional reliability checks.

  1. The effects of increasing liquid calories on gastric emptying in normal subjects

    International Nuclear Information System (INIS)

    Collins, P.; Cook, D.; Horowitz, M.; Shearman, D.; Harding, P.

    1982-01-01

    Radionuclide methods are the simplest and potentially the most accurate techniques for the measurement of gastric emptying, but there are methodological problems which may limit the sentivity and specificity of these tests. A significant source of error is photon attenuation, due to the changing depth of radionuclides in the stomach during the study. This error can be eliminated by adding counts obtained in both anterior and posterior views or by applying attenuation correction factors to the data. Radionuclides were used to study the effect of increasing the calorie content of the liquid component of a mixed solid-liquid meal on gastric emptying in normal subjects, using a single detector system, and assessed the reproductibility of the technique. The solid meal comprised 1-1.5 mCi ''in vivo'' sup(99m)Tc-labelled chicken liver which was added to 100 g of ground beef and the resultant ''hamburger'' grilled. The liquids studied were 0.5 mCi sup(113m)In-diethyltriaminepentaacetic acid (DTPA) added to 100 ml of either water, 10% dextrose or 25% dextrose. In this study the progressive increase in caloric content of the liquid meal from 0 to 0.4 to 1 kcal/ml resulted in a corresponding delay in both solid and liquid emptying. For liquids a generalised slowing of the entire emptying curve was evident, while the delay in solid emptying reflected a lengthening of the lag period, with no alteraction in the rate of linear emptying

  2. Radiolytic gas formation in high-level liquid waste solutions

    International Nuclear Information System (INIS)

    Brodda, B.-G.; Dix, Siegfried; Merz, E.R.

    1989-01-01

    High-level fission product waste solutions originating from the first-cycle raffinate stream of spent fast breeder reactor fuel reprocessing have been investigated gas chromatographically for their radiolytic and chemical gas production. The solutions showed considerable formation of hydrogen, carbon dioxide and dinitrogen oxide, whereas atmospheric oxygen was consumed completely within a short time. In particular, carbon dioxide resulted from the radiolytic degradation of entrained organic solvent. After nearly complete degradation of the organic solvent, the influence of hydrazine and nitrogen dioxide on hydrogen formation was investigated. Hydrazinium hydroxide led to the formation of dinitrogen oxide and nitrogen. After 60 d, the concentration of dinitrogen oxide had reduced to zero, whereas the amount of nitrogen formed had reached a maximum. This may be explained by simultaneous chemical and radiolytic reactions leading to the formation of dinitrogen oxide and nitrogen and photolytic fission of dinitrogen oxide. Addition of sodium nitrite resulted in the rapid formation of dinitrogen oxide. The rate of hydrogen production was not changed significantly after the addition of hydrazine or nitrite. The results indicate that under normal operating conditions no dangerous hydrogen radiolysis yields should develop in the course of reprocessing and high-level liquid waste tank storage. Organic entrainment may lead to enhanced radiolytic decomposition and thus to considerable hydrogen production rates and pressure build-up in closed systems. (author)

  3. Cement encapsulation of low-level waste liquids. Final report

    International Nuclear Information System (INIS)

    Baker, M.N.; Houston, H.M.

    1999-01-01

    Pretreatment of liquid high-level radioactive waste at the West Valley Demonstration Project (WVDP) was essential to ensuring the success of high-level waste (HLW) vitrification. By chemically separating the HLW from liquid waste, it was possible to achieve a significant reduction in the volume of HLW to be vitrified. In addition, pretreatment made it possible to remove sulfates, which posed several processing problems, from the HLW before vitrification took place

  4. New Type Multielectrode Capacitance Sensor for Liquid Level

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Y R [China University of Petroleum (Huadong), Qingdao (China); Shi, A P [Shandong University of Science and Technology, Qingdao (China); Chen, G Q [Shandong University of Science and Technology, Qingdao (China); Chang, Y Y [Shandong University of Science and Technology, Qingdao (China); Hang, Z [Shandong University of Science and Technology, Qingdao (China); Liu, B M [Binzhou University, Binzhou (China)

    2006-10-15

    This paper introduces the design of a new type multielectrode capacitance sensor for liquid level. The system regards electric field sensor MC33794 as the core and applies microcontroller MC9S12DJ128 to realize intelligent liquid level monitoring system, which overcomes the disadvantages of the traditional capacitance sensor, improves on the anti-jamming ability and the measurement precision and simplifies the system structure. Finally, the paper sums up the design of the system.

  5. On the critical temperature, normal boiling point, and vapor pressure of ionic liquids.

    Science.gov (United States)

    Rebelo, Luis P N; Canongia Lopes, José N; Esperança, José M S S; Filipe, Eduardo

    2005-04-07

    One-stage, reduced-pressure distillations at moderate temperature of 1-decyl- and 1-dodecyl-3-methylimidazolium bistriflilamide ([Ntf(2)](-)) ionic liquids (ILs) have been performed. These liquid-vapor equilibria can be understood in light of predictions for normal boiling points of ILs. The predictions are based on experimental surface tension and density data, which are used to estimate the critical points of several ILs and their corresponding normal boiling temperatures. In contrast to the situation found for relatively unstable ILs at high-temperature such as those containing [BF(4)](-) or [PF(6)](-) anions, [Ntf(2)](-)-based ILs constitute a promising class in which reliable, accurate vapor pressure measurements can in principle be performed. This property is paramount for assisting in the development and testing of accurate molecular models.

  6. Normal levels of anticoagulant heparan sulfate are not essential for normal hemostasis

    Science.gov (United States)

    HajMohammadi, Sassan; Enjyoji, Keiichi; Princivalle, Marc; Christi, Patricia; Lech, Miroslav; Beeler, David; Rayburn, Helen; Schwartz, John J.; Barzegar, Samad; de Agostini, Ariane I.; Post, Mark J.; Rosenberg, Robert D.; Shworak, Nicholas W.

    2003-01-01

    Endothelial cell production of anticoagulant heparan sulfate (HSact) is controlled by the Hs3st1 gene, which encodes the rate-limiting enzyme heparan sulfate 3-O-sulfotransferase-1 (3-OST-1). In vitro, HSact dramatically enhances the neutralization of coagulation proteases by antithrombin. The in vivo role of HSact was evaluated by generating Hs3st1–/– knockout mice. Hs3st1–/– animals were devoid of 3-OST-1 enzyme activity in plasma and tissue extracts. Nulls showed dramatic reductions in tissue levels of HSact but maintained wild-type levels of tissue fibrin accumulation under both normoxic and hypoxic conditions. Given that vascular HSact predominantly occurs in the subendothelial matrix, mice were subjected to a carotid artery injury assay in which ferric chloride administration induces de-endothelialization and occlusive thrombosis. Hs3st1–/– and Hs3st1+/+ mice yielded indistinguishable occlusion times and comparable levels of thrombin•antithrombin complexes. Thus, Hs3st1–/– mice did not show an obvious procoagulant phenotype. Instead, Hs3st1–/– mice exhibited genetic background–specific lethality and intrauterine growth retardation, without evidence of a gross coagulopathy. Our results demonstrate that the 3-OST-1 enzyme produces the majority of tissue HSact. Surprisingly, this bulk of HSact is not essential for normal hemostasis in mice. Instead, 3-OST-1–deficient mice exhibited unanticipated phenotypes suggesting that HSact or additional 3-OST-1–derived structures may serve alternate biologic roles. PMID:12671048

  7. Analysis of adaptability of radioactive liquid effluent discharge under normal condition of inland nuclear power plant

    International Nuclear Information System (INIS)

    Xu Yueping; Zhang Bing; Chen Yang; Zhu Lingqing; Tao Yunliang; Shangguan Zhihong

    2011-01-01

    The discharge of radioactive liquid effluent from inland nuclear power plant under normal operation is an important part to be considered in environmental impact assessment. Requirements of newly revised and upcoming standards GB 6249 and GB 14587 are introduced in this paper. Through an example of an inland NPP siting in the preliminary feasibility study phase, the adaptability to the relevant regulations in the site selection is analyzed. Also, the concerned problems in the design of AP1000 units are addressed. (authors)

  8. Operating safety requirements for the intermediate level liquid waste system

    International Nuclear Information System (INIS)

    1980-07-01

    The operation of the Intermediate Level Liquid Waste (ILW) System, which is described in the Final Safety Analysis, consists of two types of operations, namely: (1) the operation of a tank farm which involves the storage and transportation through pipelines of various radioactive liquids; and (2) concentration of the radioactive liquids by evaporation including rejection of the decontaminated condensate to the Waste Treatment Plant and retention of the concentrate. The following safety requirements in regard to these operations are presented: safety limits and limiting control settings; limiting conditions for operation; and surveillance requirements. Staffing requirements, reporting requirements, and steps to be taken in the event of an abnormal occurrence are also described

  9. Visualizing Tensor Normal Distributions at Multiple Levels of Detail.

    Science.gov (United States)

    Abbasloo, Amin; Wiens, Vitalis; Hermann, Max; Schultz, Thomas

    2016-01-01

    Despite the widely recognized importance of symmetric second order tensor fields in medicine and engineering, the visualization of data uncertainty in tensor fields is still in its infancy. A recently proposed tensorial normal distribution, involving a fourth order covariance tensor, provides a mathematical description of how different aspects of the tensor field, such as trace, anisotropy, or orientation, vary and covary at each point. However, this wealth of information is far too rich for a human analyst to take in at a single glance, and no suitable visualization tools are available. We propose a novel approach that facilitates visual analysis of tensor covariance at multiple levels of detail. We start with a visual abstraction that uses slice views and direct volume rendering to indicate large-scale changes in the covariance structure, and locations with high overall variance. We then provide tools for interactive exploration, making it possible to drill down into different types of variability, such as in shape or orientation. Finally, we allow the analyst to focus on specific locations of the field, and provide tensor glyph animations and overlays that intuitively depict confidence intervals at those points. Our system is demonstrated by investigating the effects of measurement noise on diffusion tensor MRI, and by analyzing two ensembles of stress tensor fields from solid mechanics.

  10. Comparison of different methods for liquid level adjustment in tank prover calibration

    International Nuclear Information System (INIS)

    Garcia, D A; Farias, E C; Gabriel, P C; Aquino, M H; Gomes, R S E; Aibe, V Y

    2015-01-01

    The adjustment of the liquid level during the calibration of tank provers with fixed volume is normally done by overfill but it can be done in different ways. In this article four level adjustment techniques are compared: plate, pipette, ruler and overfill adjustment. The adjustment methods using plate and pipette presented good agreement with the tank's nominal volume and lower uncertainty among the tested methods

  11. Mathematical modelling of liquid meniscus shape in cylindrical micro-channel for normal and micro gravity conditions

    Science.gov (United States)

    Marchuk, Igor; Lyulin, Yuriy

    2017-10-01

    Mathematical model of liquid meniscus shape in cylindrical micro-channel of the separator unit of condensing/separating system is presented. Moving liquid meniscus in the 10 μm cylindrical microchannel is used as a liquid lock to recover the liquid obtained by condensation from the separators. The main goal of the liquid locks to prevent penetration of a gas phase in the liquid line at the small flow rate of the condensate and because of pressure fluctuations in the vapor-gas-liquid loop. Calculation of the meniscus shape has been performed for liquid FC-72 at different values of pressure difference gas - liquid and under normal and micro gravity conditions.

  12. Meniscus and viscous forces during normal separation of liquid-mediated contacts

    International Nuclear Information System (INIS)

    Cai Shaobiao; Bhushan, Bharat

    2007-01-01

    Menisci form between two solid surfaces with the presence of an ultra-thin liquid film. Meniscus and viscous forces contribute to an adhesive force when two surfaces are separated. The adhesive force can be very large and can result in high friction, stiction and possibly high wear. The situation may become more pronounced when the contacting surfaces are ultra-smooth and the normal load is small, as is common for micro-/nanodevices. In this study, equations for meniscus and viscous forces during separation of two flat surfaces, and a sphere and a flat surface, are developed, and the corresponding adhesive forces contributed by these two types of forces are examined. The geometric meniscus curvatures and break point are theoretically determined, and the role of meniscus and viscous forces is evaluated during separation. The influence of separation distance, liquid thickness, meniscus area, separation time, liquid properties and contact angles are analyzed. Critical meniscus areas at which transition in the dominance of meniscus to viscous forces occurs for different given conditions, i.e. various initial liquid thicknesses, contact angles and designated separation time, are identified. The analysis provides a fundamental understanding of the physics of separation process, and insights into the relationships between meniscus and viscous forces. It is also valuable for the design of the interface for various devices

  13. Treatment of ORNL liquid low-level waste

    International Nuclear Information System (INIS)

    Berry, J.B.; Brown, C.H. Jr.; Fowler, V.L.; Robinson, S.M.

    1988-01-01

    Discontinuation of the hydrofracture disposal method at Oak Ridge National Laboratory (ORNL) has caused intensive efforts to reduce liquid waste generation. Improving the treatment of slightly radioactive liquid waste, called process waste, has reduced the volume of the resulting contaminated liquid radioactive waste effluent by 66%. Proposed processing improvements could eliminate the contaminated liquid effluent and reduce solid low-level waste by an additional one-third. The improved process meets stringent discharge limits for radionuclides. Discharge limits for radionuclides are expected to be enforced at the outfall of the treatment plant to a creek; currently, limits are enforced at the reservation boundary. Plant discharge is monitored according to the National Pollutant Discharge Elimination System (NPDES) permit for ORNL. 1 ref., 4 figs., 2 tabs

  14. Commissioning of the XENON1T liquid level measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Geis, Christopher [Institut fuer Physik, Johannes Gutenberg-Universitaet, Mainz (Germany)

    2016-07-01

    Two-phase xenon time projection chambers (TPCs) have been operated very successfully in direct detection experiments for dark matter. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level needs to be monitored and controlled with sub-millimeter precision. We present the installation, commissioning and first measurement data of two kinds of level meters operated in the XENON1T TPC: short level meters are three-plated capacitors measuring the level of the liquid-gas interface with a measurement range h∼5 mm and a resolution of ΔC/h∼1 pF/mm. The long level meters are cylindrical double-walled capacitors, measuring the overall filling level of the XENON1T TPC at a measurement range of h=1.4 m and a resolution of ΔC/h∼0.1 pF/mm. Further, we present the design and programming of the readout electronic based on the UTI chip by Smartec, which allows to read all six levelmeters simultaneously.

  15. Continuous liquid level monitoring sensor system using fiber Bragg grating

    Science.gov (United States)

    Sengupta, Dipankar; Kishore, Putha

    2014-01-01

    The design and packaging of simple, small, and low cost sensor heads, used for continuous liquid level measurement using uniformly thinned (etched) optical fiber Bragg grating (FBG) are proposed. The sensor system consists of only an FBG and a simple detection system. The sensitivity of sensor is found to be 23 pm/cm of water column pressure. A linear optical fiber edge filter is designed and developed for the conversion of Bragg wavelength shift to its equivalent intensity. The result shows that relative power measured by a photo detector is linearly proportional to the liquid level. The obtained sensitivity of the sensor is nearly -15 mV/cm.

  16. Ultrasonic level sensors for liquids under high pressure

    Science.gov (United States)

    Zuckerwar, A. J.; Mazel, D. S.; Hodges, D. Y.

    1986-01-01

    An ultrasonic level sensor of novel design continuously measures the level of a liquid subjected to a high pressure (up to about 40 MPa), as is sometimes required for the effective transfer of the liquid. The sensor operates as a composite resonator fabricated from a standard high-pressure plug. A flat-bottom hole is machined into the plug along its center line. An ultrasonic transducer is bonded rigidly to the interior surface of the bottom wall, while the exterior surface is in contact with the liquid. Although the bottom wall is designed to satisfy the pressure code, it is still sufficiently thin to permit ready excitation of the axisymmetric plate modes of vibration. The liquid level is measured by a conventional pulse-echo technique. A prototype sensor was tested successfully in a 2300-l water vessel at pressures up to about 37 MPa. A spectral analysis of the transmitted pulse reveals that the flexural, extensional, thickness-shear, and radial plate modes are excited into vibration, but none of these appears to be significantly affected by the pressurization of the liquid.

  17. 2-deoxyglucose tissue levels and insulin levels following tolazamide dosing in normal and obese mice

    International Nuclear Information System (INIS)

    Skillman, C.A.; Fletcher, H.P.

    1986-01-01

    The effect of tolazamide (TZ), a sulfonylurea, on 14 C-2-deoxyglucose ( 14 C-2DG) tissue distribution and insulin levels of normal and obese mice was investigated using an in vivo physiological method. Acute doses of TZ (50 mg/kg ip) increased 14 C-2DG levels in gastrocnemius muscle and retroperitoneal fat and produced a transient elevation of insulin which most likely accounts for the increased 14 C-2DG levels in muscle and fat. The results demonstrate that the in vivo 14 C-2DG method produced results consistent with known actions of sulfonylureas on in vitro hexose assimilation in muscle and fat. Subchronic treatment (7 days) with TZ 50 mg/kg ip twice daily did not result in increased insulin-stimulated 14 C-2DG tissue levels in normal mice when compared to saline treated controls. However, insulin levels were lower in mice treated subchronically with TZ compared to saline controls suggesting an enhancement of insulin action. Viable yellow obese mice represent a model of maturity onset obesity presenting with insulin resistance. The insulin resistance of this obese strain appears to reside in the fat tissue as assessed by comparing 14 C-2DG tissue levels of obese mice with lean littermate controls. Subchronic TZ treatment had no effect on 14 C-2DG uptake in fat or muscle tissue of viable yellow obese mice and did not alter their plasma insulin levels. It appears that genetically obese viable mice may be resistant to subchronic treatment with TZ. (author)

  18. Lower polyamine levels in breast milk of obese mothers compared to mothers with normal body weight.

    Science.gov (United States)

    Ali, M Atiya; Strandvik, B; Palme-Kilander, C; Yngve, A

    2013-07-01

    Obesity is associated with risks for mother and infant, and the mothers' dietary habits influence breast milk composition. Polyamines are secreted in breast milk and are essential for the regulation of intestinal and immune function in newborns and infants. The present study aimed to investigate the level of polyamines in human milk obtained from obese and normal weight mothers at different times of lactation. Breast milk from 50 mothers was obtained at day 3, and at 1 and 2 months after delivery. The mothers had normal body weight [body mass index (BMI) obese (BMI > 30 kg/m(2) ). A subgroup of obese mothers participated in a weight reduction programme during pregnancy. Polyamines were analysed using high-performance liquid chromatography. The total polyamine content was significantly lower at all times in breast milk from obese mothers compared to milk from controls. Spermine levels did not differ between groups at any time in contrast to the levels of putrescine and spermidine. Putrescine concentrations were highest on day 3 and spermidine and spermine were highest at 1 month of lactation. The obese mothers, who received dietary advice during pregnancy based on the Nordic Nutrition Recommendations, had higher concentrations of putrescine and spermidine in their milk than the obese mothers without any intervention. Polyamine concentrations were lower in breast milk from obese mothers compared to mothers with a normal weight. General dietary intervention in obese mothers increased the polyamine levels, suggesting that the low levels in obesity were at least partly associated with food habits. However, the consistency of spermine suggests a special metabolic function of this polyamine. © 2013 The Authors Journal of Human Nutrition and Dietetics © 2013 The British Dietetic Association Ltd.

  19. Glass-solidification method for high level radioactive liquid waste

    International Nuclear Information System (INIS)

    Kawamura, Kazuhiro; Kometani, Masayuki; Sasage, Ken-ichi.

    1996-01-01

    High level liquid wastes are removed with precipitates mainly comprising Mo and Zr, thereafter, the high level liquid wastes are mixed with a glass raw material comprising a composition having a B 2 O 3 /SiO 2 ratio of not less than 0.41, a ZnO/Li 2 O ratio of not less than 1.00, and an Al 2 O 3 /Li 2 O ratio of not less than 2.58, and they are melted and solidified into glass-solidification products. The liquid waste content in the glass-solidification products can be increased up to about 45% by using the glass raw material having such a predetermined composition. In addition, deposition of a yellow phase does not occur, and a leaching rate identical with that in a conventional case can be maintained. (T.M.)

  20. Identification and quantification of amino acids from psoriatic and normal epidermis by high performance liquid chromatography

    International Nuclear Information System (INIS)

    Mahesar, S.M.; Khuhawar, M.Y.

    2010-01-01

    In this study, a modified fluorescence technique high performance liquid chromatography (HPLC) was adapted to separate the amino acids from the hydrolyzed keratin samples. These samples obtained from the epidermal layer of the normal and psoriatic human subjects. The keratin extracts are quantified in gram percentage of the dried skin and the amino acids concentrations are measured in mu g/g, mean retention time (tR), slope value and the coefficient of determination (r2) of each eluted amino acid is calculated. The coefficients of variation for amino acid standards ranged from 0.12% to 0.28%, mean, standard deviation of peak area and coefficients of variation of peak area were calculated. From the normal hydrolysated keratin protein fraction, 12 amino acids were determined and identified as aspartic acid, glutamic acid, asparagines, serine, glutamine, glycine, histidine, citrulline, arganine, fi-alanine, tyrosine, and valine. These amino acids were also determined in psoriatic samples while standard deviations (SD), standard error mean (SEM) and coefficient variation (CV%) of normal and psoriatic samples were also calculated. The higher concentration of amino acids in normal samples against psoriatic samples determined as glutamic acid 92.76+- 16. 83/50. 87+-9.88, glutamine 198.05+-18.74/19.74+-3.74 while higher concentrations of amino acids determined in psoriatic samples against normal samples as asparagines 81. 06+-10+-10.62/29. 98+-3.641; arganine 164.42+-35. 11/46. 14+-46, tyrosine 214.38+-29. 61/59. 64+-8. 82, and valine 169.7+-19.35/128.06+-15.14.1 is concluded that the absolute concentration of amino acids in psoriatic skin indicated a number of variations as compared to normal skin samples. (author)

  1. Serum levels of growth hormone binding protein in children with normal and precocious puberty

    DEFF Research Database (Denmark)

    Juul, A; Fisker, Sidse; Scheike, Thomas Harder

    2000-01-01

    To study the regulation of GHBP serum levels by gonadal steroids in normal and precocious puberty.......To study the regulation of GHBP serum levels by gonadal steroids in normal and precocious puberty....

  2. The NA62 Liquid Krypton Electromagnetic Calorimeter Level 0 Trigger

    CERN Document Server

    INSPIRE-00293812; Paoluzzi, Giovanni; Salamon, Andrea; Salina, Gaetano; Santovetti, Emanuele; Scarfi, Francesco M.; Bonaiuto, Vincenzo; Sargeni, Fausto

    2012-01-01

    The NA62 experiment at CERN SPS aims to measure the Branching Ratio of the very rare kaon decay K+ -> pi+ nu nubar collecting O(100) events with a 10% background to make a stringent test of the Standard Model. One of the main backgrounds to the proposed measurement is represented by the K+ -> pi+ pi0 decay. To suppress this background an efficient photo veto system is foreseen. In the 1-10 mrad angular region the NA48 high performance liquid krypton electromagnetic calorimeter is used. The design, implementation and current status of the Liquid Krypton Electromagnetic Calorimeter Level 0 Trigger are presented.

  3. The NA62 Liquid Krypton Electromagnetic Calorimeter Level 0 Trigger

    CERN Document Server

    INSPIRE-00646848; Fucci, Adolfo; Paoluzzi, Giovanni; Salamon, Andrea; Salina, Gaetano; Santovetti, Emanuele; Scarfi, Francesco M.; Sargeni, Fausto

    2011-01-01

    The NA62 experiment at CERN SPS aims to measure the Branching Ratio of the very rare kaon decay K+ -> pi+ nu nubar collecting O(100) events with a 10% background to make a stringent test of the Standard Model. One of the main backgrounds to the proposed measurement is represented by the K+ -> pi+ pi0 decay. To suppress this background an efficient photo veto system is foreseen. In the 1-10 mrad angular region the NA48 high performance liquid krypton electromagnetic calorimeter is used. The design, implementation and current status of the Liquid Krypton Electromagnetic Calorimeter Level 0 Trigger are presented.

  4. Aspects of the Normalization of Managerial Accounting in Romania on a Microeconomic Level

    Directory of Open Access Journals (Sweden)

    Sorin BRICIU

    2011-03-01

    Full Text Available The article presents the general frame of the normalization of managerial accounting on a national level, following an incursion in its international normalization. The objectives of the normalization of managerial accounting in Romania are presented into detail, from the authors’ point of view, as well as the profile and attributions of the managerial accountant as a normalizer. The article ends with the authors’ conclusions related to the normalization of managerial accounting in Romania on a microeconomic level.

  5. Empathy, normality and responsiveness among street-level bureaucrats

    DEFF Research Database (Denmark)

    Møller, Marie Østergaard; Nielsen, Vibeke Lehmann

    2014-01-01

    Within the public sector it is a permanent dilemma that we on one hand – on the grounds of effectiveness and flexibility – want employees to have discretion and autonomy, but at the same time want to make sure that citizens and clients of the public sector are treated equally and independent of w...... this paper discusses and analyzes how perceptions of local target group’s problem portfolio (normality perceptions) conditions the behavioral effects of personal attributes/personality traits (differences in empathy)....

  6. Calcitonin serum levels in normal and in pathological conditions

    International Nuclear Information System (INIS)

    Ziliotto, D.; Luisetto, G.; Zanatta, G.P.; Cataldi, F.; Zangari, M.; Gangemi, M.; Melanotte, P.L.; Caira, S.

    1985-01-01

    Radioimmunoassay of calcitonin (CT) gives variable results because of differences in sensitivity and specificity of antibody preparations and because of the known immunoheterogeneity of circulating CT. The difficulties in interpretation of data has hindered our understanding of normal and abnormal CT physiology. The authors separated the biologically active CT monomer (CTm) from the higher molecular weight biologically inactive forms before RIA. It makes it possible to re-evaluate the behaviour of CT in physiological conditions and to study its changes in diseases in which bone and mineral metabolism are in some way compromised. (Auth.)

  7. Acid fractionation for low level liquid waste cleanup and recycle

    International Nuclear Information System (INIS)

    Gombert, D. II; McIntyre, C.V.; Mizia, R.E.; Schindler, R.E.

    1990-01-01

    At the Idaho Chemical Processing Plant, low level liquid wastes containing small amounts of radionuclides are concentrated via a thermosyphon evaporator for calcination with high level waste, and the evaporator condensates are discharged with other plant wastewater to a percolation pond. Although all existing discharge guidelines are currently met, work has been done to reduce all waste water discharges to an absolute minimum. In this regard, a 15-tray acid fractionation column will be used to distill the mildly acidic evaporator condensates into concentrated nitric acid for recycle in the plant. The innocuous overheads from the fractionator having a pH greater than 2, are superheated and HEPA filtered for atmospheric discharge. Nonvolatile radionuclides are below detection limits. Recycle of the acid not only displaces fresh reagent, but reduces nitrate burden to the environment, and completely eliminates routine discharge of low level liquid wastes to the environment

  8. Patients with fibromyalgia have normal serum levels of hyaluronic acid

    DEFF Research Database (Denmark)

    Bliddal, Henning; Møller, H J; Schaadt, M

    2000-01-01

    OBJECTIVE: To investigate the levels of hyaluronic acid (HA) in Danish patients with fibromyalgia (FM). METHODS: Serum levels of HA were determined in 53 patients with established FM and 55 control samples using a radiometric assay. Values were correlated to clinical disease severity variables...

  9. Low level radioactive liquid waste decontamination by electrochemical way

    International Nuclear Information System (INIS)

    Tronche, E.

    1994-10-01

    As part of the work on decontamination treatments for low level radioactive aqueous liquid wastes, the study of an electro-chemical process has been chosen by the C.E.A. at the Cadarache research centre. The first part of this report describes the main methods used for the decontamination of aqueous solutions. Then an electro-deposition process and an electro-dissolution process are compared on the basis of the decontamination results using genuine radioactive aqueous liquid waste. For ruthenium decontamination, the former process led to very high yields (99.9 percent eliminated). But the elimination of all the other radionuclides (antimony, strontium, cesium, alpha emitters) was only favoured by the latter process (90 percent eliminated). In order to decrease the total radioactivity level of the waste to be treated, we have optimized the electro-dissolution process. That is why the chemical composition of the dissolved anode has been investigated by a mixture experimental design. The radionuclides have been adsorbed on the precipitating products. The separation of the precipitates from the aqueous liquid enabled us to remove the major part of the initial activity. On the overall process some operations have been investigated to minimize waste embedding. Finally, a pilot device (laboratory scale) has been built and tested with genuine radioactive liquid waste. (author). 77 refs., 41 tabs., 55 figs., 4 appendixes

  10. Chain length effects on the vibrational structure and molecular interactions in the liquid normal alkyl alcohols

    Science.gov (United States)

    Kiefer, Johannes; Wagenfeld, Sabine; Kerlé, Daniela

    2018-01-01

    Alkyl alcohols are widely used in academia, industry, and our everyday lives, e.g. as cleaning agents and solvents. Vibrational spectroscopy is commonly used to identify and quantify these compounds, but also to study their structure and behavior. However, a comprehensive investigation and comparison of all normal alkanols that are liquid at room temperature has not been performed, surprisingly. This study aims at bridging this gap with a combined experimental and computational effort. For this purpose, the alkyl alcohols from methanol to undecan-1-ol have been analyzed using infrared and Raman spectroscopy. A detailed assignment of the individual peaks is presented and the influence of the alkyl chain length on the hydrogen bonding network is discussed. A 2D vibrational mapping allows a straightforward visualization of the effects. The conclusions drawn from the experimental data are backed up with results from Monte Carlo simulations using the simulation package Cassandra.

  11. Monitoring PWR reactor vessel liquid level with SPNDs during LOCAs

    International Nuclear Information System (INIS)

    Adams, J.P.

    1982-01-01

    Data from in-core self-powered neutron detectors taken during two nuclear loss-of-coolant accident simulations have been correlated with core moderator density changes. The detector current attenuation has been calculated during blowdown and reflood phases of the simulation. Based on these data, it is concluded that these detectors could be used to monitor reactor vessel liquid level during loss-of-coolant accidents in pressurized water reactors

  12. Treatment of low-level liquid radioactive wastes by electrodialysis

    International Nuclear Information System (INIS)

    DelDebbio, J.A.; Donovan, R.I.

    1986-01-01

    This paper presents the results of pilot plant studies on the use of electrodialysis (ED) for the removal of radioactive and chemical contaminants from acidic low-level radioactive wastes resulting from nuclear fuel reprocessing operations. Decontamination efficiencies are reported for strontium-90, cesium-137, iodine-129, ruthenium-106 and mercury. Data for contaminant adsorption on ED membranes and liquid waste volumes generated are also presented

  13. Denitration and chemical precipitation of medium level liquid wastes and conditioning of high level wastes from low level liquid wastes by a roll dryer and subsequent vitrification

    International Nuclear Information System (INIS)

    Halaszovich, S.; Dix, S.; Harms, R.

    1987-01-01

    Medium level liquid waste (MAW) from the reprocessing need after being fixed in cement an additional shielding to meet required radiation limits for handling and transportation. Normally this shielding consists of concrete and its weight and volume is several times higher than that of the waste product itself. By means of caesium separation using nickel-potassium-hexacyanoferrate and after few years of interim storage waiting for the decay of Ruthenium and Antimony the activities will be reduced below permissible values. (13 MBq/l in waste solution for Cs, 28 MBq/l for Sb and 34 MBq/l for Ru). Below these limits there is no need for additional shielding after cementation in a 400 l drum. Experimental results show, that Caesium can be precipitated and separated effectively not only in laboratory but also in a larger scale under hot cell conditions. The process investigated in this work has been developed from the FIPS process for vitrification of highly radioactive fission product solutions. It consists of: denitration, precipitation, sludge separation, drying and melting

  14. Low level liquid scintillation analysis for environmental and biomedical quantitation

    International Nuclear Information System (INIS)

    Kessler, M.J.

    1991-01-01

    Over the past five years low level liquid scintillation counting has become increasing popular because of the large number of applications which can be performed using this technique. These applications include environmental monitoring ( 3 H, 90 Sr/ 90 Y, etc.), radiocarbon dating (for age determination to 50,000 years), food adulteration studies (alcohol and beverage industries), radon monitoring (air/water), nuclear power plant monitoring (low level 3 H) and metabolism studies (pharmaceutical research). These applications can be performed with either a dedicated low level LSC or using a standard liquid scintillation counter in conjunction with the new technique of time-resolved LSC (TR-LSC). This technique when used on a standard LSC reduces the instrument background without substantially effecting the background, thus increasing the performance (E 2 /B) of the LSC. Data will be presented for each of the applications mentioned above, comparing the standard LSC and the new TR-LSC techniques. The optimization of the samples for each of these applications will be explored in detail with experimental results. In conclusion, by using the TR-LSC technique in conjunction with a standard LSC the performance of the standard LSC can be increased substantially without dedicating the LSC to doing only low level samples

  15. Monitoring of low-level radioactive liquid effluent in Tokai reprocessing plant

    International Nuclear Information System (INIS)

    Mizutani, Tomoko; Koarashi, Jun; Takeishi, Minoru

    2009-01-01

    The Tokai reprocessing plant (TRP), the first reprocessing plant in Japan, has discharged low-level liquid wastes to the Pacific Ocean since the start of its operation in 1977. We have performed liquid effluent monitoring to realize an appropriate radioactive discharge control. Comparing simple and rapid analytical methods with labor-intensive radiochemical analyses demonstrated that the gross-alpha and gross-beta activities agreed well with the total activities of plutonium isotopes ( 238 Pu and 239+240 Pu) and major beta emitters (e.g., 90 Sr and 137 Cs), respectively. The records of the radioactive liquid discharge from the TRP showed that the normalized discharges of all nuclides, except for 3 H, were three or four orders of magnitude lower than those from the Sellafield and La Hague reprocessing plants. This was probably due to the installation of multistage evaporators in the liquid waste treatment process in 1980. The annual public doses for a hypothetical person were estimated to be less than 0.2 μSv y -1 from the aquatic pathway. Plutonium radioactivity ratios ( 238 Pu/ 239+240 Pu) of liquid effluents were determined to be 1.3-3.7, while those of the seabed sediment samples collected around the discharge point were 0.003-0.059, indicating no remarkable accumulation of plutonium in the regional aquatic environment. Thus, we concluded that there were no significant radiological effects on the public and the aquatic environment during the past 30-year operation of the TRP. (author)

  16. Purification of flavonoids from licorice using an off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method.

    Science.gov (United States)

    Fan, Yunpeng; Fu, Yanhui; Fu, Qing; Cai, Jianfeng; Xin, Huaxia; Dai, Mei; Jin, Yu

    2016-07-01

    An orthogonal (71.9%) off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self-made Click TE-Cys (60 μm) solid-phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE-Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co-eluted in the first dimension were selected for further purification using reversed-phase liquid chromatography. Multiple compounds could be isolated from one normal-phase fraction and some compounds with bad resolution in one-dimensional liquid chromatography could be prepared in this two-dimensional system owing to the orthogonal separation. Moreover, this two-dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off-line two-dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Flow proportional sampling of low level liquid effluent

    International Nuclear Information System (INIS)

    Colley, D.; Jenkins, R.

    1989-01-01

    A flow proportional sampler for use on low level radioactive liquid effluent has been developed for installation on all CEGB nuclear power stations. The sampler, operates by drawing effluent continuously from the main effluent pipeline, through a sampler loop and returning it to the pipeline. The effluent in this loop is sampled by taking small, frequent aliquots using a linear acting shuttle valve. The frequency of operation of this valve is controlled by a flowmeter installed in the effluent line; sampling rate being directly proportional to effluent flowrate. (author)

  18. Landau Levels of Majorana Fermions in a Spin Liquid.

    Science.gov (United States)

    Rachel, Stephan; Fritz, Lars; Vojta, Matthias

    2016-04-22

    Majorana fermions, originally proposed as elementary particles acting as their own antiparticles, can be realized in condensed-matter systems as emergent quasiparticles, a situation often accompanied by topological order. Here we propose a physical system which realizes Landau levels-highly degenerate single-particle states usually resulting from an orbital magnetic field acting on charged particles-for Majorana fermions. This is achieved in a variant of a quantum spin system due to Kitaev which is distorted by triaxial strain. This strained Kitaev model displays a spin-liquid phase with charge-neutral Majorana-fermion excitations whose spectrum corresponds to that of Landau levels, here arising from a tailored pseudomagnetic field. We show that measuring the dynamic spin susceptibility reveals the Landau-level structure by a remarkable mechanism of probe-induced bound-state formation.

  19. Quantitation of bilirubin conjugates with high-performance liquid chromatography in patients with low total serum bilirubin levels

    NARCIS (Netherlands)

    Jansen, P. L.; Cuypers, H. T.; Peters, W. H.

    1984-01-01

    Bilirubin mono- and diconjugates were determined by alkaline methanolysis and high-performance liquid chromatography (HPLC) in serum from patients with metastatic liver disease and liver cirrhosis. Conjugates could be detected and quantitated at normal or low total bilirubin levels. Comparison with

  20. Cryogenic Liquid Level-Sensing using Fiber-Optic Strain Sensor (FOSS) Technology Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Armstrong innovators have developed a highly accurate method for measuring liquid levels using optical fibers. Unlike liquid level gauges that rely on discrete...

  1. A method for assay of special nuclear material in high level liquid waste streams

    International Nuclear Information System (INIS)

    Venkata Subramani, C.R.; Swaminathan, K.; Asuvathraman, R.; Kutty, K.V.G.

    2003-01-01

    The assay of special nuclear material in the high level liquid waste streams assumes importance as this is the first stage in the extraction cycle and considerable losses of plutonium could occur here. This stream contains all the fission products as also the minor actinides and hence normal nuclear techniques cannot be used without prior separation of the special nuclear material. This paper presents the preliminary results carried out using wavelength dispersive x-ray fluorescence as part of the developmental efforts to assay SNM in these streams by instrumental techniques. (author)

  2. Best-Matched Internal Standard Normalization in Liquid Chromatography-Mass Spectrometry Metabolomics Applied to Environmental Samples.

    Science.gov (United States)

    Boysen, Angela K; Heal, Katherine R; Carlson, Laura T; Ingalls, Anitra E

    2018-01-16

    The goal of metabolomics is to measure the entire range of small organic molecules in biological samples. In liquid chromatography-mass spectrometry-based metabolomics, formidable analytical challenges remain in removing the nonbiological factors that affect chromatographic peak areas. These factors include sample matrix-induced ion suppression, chromatographic quality, and analytical drift. The combination of these factors is referred to as obscuring variation. Some metabolomics samples can exhibit intense obscuring variation due to matrix-induced ion suppression, rendering large amounts of data unreliable and difficult to interpret. Existing normalization techniques have limited applicability to these sample types. Here we present a data normalization method to minimize the effects of obscuring variation. We normalize peak areas using a batch-specific normalization process, which matches measured metabolites with isotope-labeled internal standards that behave similarly during the analysis. This method, called best-matched internal standard (B-MIS) normalization, can be applied to targeted or untargeted metabolomics data sets and yields relative concentrations. We evaluate and demonstrate the utility of B-MIS normalization using marine environmental samples and laboratory grown cultures of phytoplankton. In untargeted analyses, B-MIS normalization allowed for inclusion of mass features in downstream analyses that would have been considered unreliable without normalization due to obscuring variation. B-MIS normalization for targeted or untargeted metabolomics is freely available at https://github.com/IngallsLabUW/B-MIS-normalization .

  3. Solidification of high level liquid waste (HLLW) into ceramics by sintering process

    International Nuclear Information System (INIS)

    Masuda, Sumio; Oguino, Naohiko; Tsunoda, Naomi; O-oka, Kazuo; Ohta, Takao.

    1979-01-01

    One of the alternatives to vitrified solid which is acceptable and well characterized for storing radioactive HLLW with desirable long-term stability is ceramics. On the other hand, the solidification process of highly radioactive wastes should be simple and suitable for continuous production. On the above described basis, the authors have made preliminary study on the production of sintered ceramics by the addition of several oxides to HLLW. The simulated waste and additive oxides were pressed in a mold to make the preforms of 50 mm diameter and 10 to 15 mm thick. The preforms were then normally sintered at temperature from 1000 to 1400 deg C for 2 to 4 hours. The characterization of the sintered solids revealed the following facts. (1) X-ray diffraction analysis showed that the expected crystals were formed by normal-sintering as well as by hot-pressing. (2) The bulk density of the ceramics by normal-sintering was around 90 to 95% of the assumed theoretical values. (3) The leach-rate of the solids was affected by the bulk density. (4) Other properties of the solids, such as thermal expansion or thermal conductivity, are dominantly determined by those of main crystals in the solids. Sintering process is generally simple and productive as far as normal sintering is concerned. However, hot-pressing is an intermittent and time consuming process. From this fact, the authors intended to adopt the normal sintering process for the ceramic solidification of high level liquid wastes. (Wakatsuki, Y.)

  4. Hypothetical accidents at disposal facilities for high-level liquid radioactive wastes and pulps

    International Nuclear Information System (INIS)

    Kabakchi, S.A.; Zagainov, V.A.; Lishnikov, A.A.; Nazin, E.R.

    1994-01-01

    Four accidents are postulated and analyzed for interim storage of high-level, liquid radioactive wastes at a fuel reprocessing facility. Normal waste storage operation is based on wastes stored in steel drums, partially buried in concrete canyons, and equipped with heat exchangers for cooling and ventilation systems for removal of explosive gases and vapors. The accident scenarios analyzed are: (1) shutdown of ventilation with open entrance and exit ventilation pipes, (2) shutdown of ventilation with closed entrance and exit ventilation pipes, (3) shutdown of the cooling system with normally functioning ventilation, and (4) simultaneous cooling and ventilation system failure (worst case). A mathematical model was developed and used to calculate radiation consequences of various accidents. Results are briefly presented for the worst case scenario and compared to an actual accident for model validation. 17 refs., 3 figs., 1 tab

  5. 4He-impurity effects on normal liquid 3He at low temperatures I - preliminary ideas and calculations

    International Nuclear Information System (INIS)

    Ghassib, H.B.; Chatterjee, S.

    1982-02-01

    The effects of 4 He impurities on the low-temperature properties of normal liquid 3 He are explored. It is argued that these effects should manifest themselves in, among other properties, the liquid structure factor at very low temperatures and momentum transfers, the acoustic impedance near the transition region from the zero- to the first-sound regime, the propagation of sound, the phase diagram, and the magnetic properties - including the magnetokinetic coefficients of the spin-polarized system. Several experiments are suggested to detect these macroscopic manifestations. (author)

  6. Automatic cryogenic liquid level controller is safe for use near combustible substances

    Science.gov (United States)

    Krejsa, M.

    1966-01-01

    Automatic mechanical liquid level controller that is independent of any external power sources is used with safety in the presence of combustibles. A gas filled capillary tube which leads from a pressurized chamber, is inserted into the cryogenic liquid reservoir and becomes a liquid level sensing element or probe.

  7. Apparatus for controlling coolant level in a liquid-metal-cooled nuclear reactor

    Science.gov (United States)

    Jones, Robert D.

    1978-01-01

    A liquid-metal-cooled fast-breeder reactor which has a thermal liner spaced inwardly of the pressure vessel and includes means for passing bypass coolant through the annulus between the thermal liner and the pressure vessel to insulate the pressure vessel from hot outlet coolant includes control ports in the thermal liner a short distance below the normal operating coolant level in the reactor and an overflow nozzle in the pressure vessel below the control ports connected to an overflow line including a portion at an elevation such that overflow coolant flow is established when the coolant level in the reactor is above the top of the coolant ports. When no makeup coolant is added, bypass flow is inwardly through the control ports and there is no overflow; when makeup coolant is being added, coolant flow through the overflow line will maintain the coolant level.

  8. Apparatus for controlling coolant level in a liquid-metal-cooled nuclear reactor

    International Nuclear Information System (INIS)

    Jones, R.D.

    1978-01-01

    A liquid-metal-cooled fast-breeder reactor which has a thermal liner spaced inwardly of the pressure vessel and includes means for passing bypass coolant through the annulus between the thermal liner and the pressure vessel to insulate the pressure vessel from hot outlet coolant includes control ports in the thermal liner a short distance below the normal operating coolant level in the reactor and an overflow nozzle in the pressure vessel below the control ports connected to an overflow line including a portion at an elevation such that overflow coolant flow is established when the coolant level in the reactor is above the top of the coolant ports. When no makeup coolant is added, bypass flow is inwardly through the control ports and there is no overflow; when makeup coolant is being added, coolant flow through the overflow line will maintain the coolant level

  9. Radionuclide blood levels during cisternography of patients with normal-pressure hydrocephalus or Alzheimer's disease

    International Nuclear Information System (INIS)

    Mahaley, M.S. Jr.; Wilkinson, R.H. Jr.; Sivalingham, S.; Friedman, H.; Tyson, W.; Goodrich, J.K.

    1974-01-01

    Various diagnostic procedures were compared during investigations of 37 dementia patients undergoing differential study for normal-pressure hydrocephalus or Alzheimer's disease. A diminished radionuclide level in the blood, with abnormal cisternography and pneumoencephalography, provided the most valuable diagnostic evidence of normal-pressure hydrocephalus. (U.S.)

  10. Gold in semen: Level in seminal plasma and spermatozoa of normal ...

    African Journals Online (AJOL)

    The study was conducted to understand the amount of gold in semen of normal and different infertile conditions. Gold was estimated in normal (n38) and pathological conditions (n86) by employing Atomic Absorption Spectrophotometer. Gold level observed in seminal plasma was as follows: in normozoospermia (n38) ...

  11. Angiogenic effects of cryosurgery with liquid nitrogen on the normal skin of rats, through morphometric study.

    Science.gov (United States)

    Pimentel, Camila Bianco; Moraes, Aparecida Machado de; Cintra, Maria Letícia

    2014-01-01

    Cryosurgery is an efficient therapeutic technique used to treat benign and malignant cutaneous diseases. The primary active mechanism of cryosurgery is related to vascular effects on treated tissue. After a cryosurgical procedure, exuberant granulation tissue is formed at the injection site, probably as a result of angiogenic stimulation of the cryogen and inflammatory response, particularly in endothelial cells. To evaluate the angiogenic effects of freezing, as part of the phenomenon of healing rat skin subjected to previous injury. Two incisions were made in each of the twenty rats, which were divided randomly into two groups of ten. After 3 days, cryosurgery with liquid nitrogen was performed in one of incisions. The rats' samples were then collected, cut and stained to conduct histopathological examination, to assess the local angiogenesis in differing moments and situations. It was possible to demonstrate that cryosurgery, in spite of promoting cell death and accentuated local inflammation soon after its application, induces quicker cell proliferation in the affected tissue and maintenance of this rate in a second phase, than in tissue healing without this procedure. These findings, together with the knowledge that there is a direct relationship between mononuclear cells and neovascularization (the development of a rich system of new vessels in injury caused by cold), suggest that cryosurgery possesses angiogenic stimulus, even though complete healing takes longer to occur. The significance level for statistical tests was 5% (p<0,05).

  12. Diurnal levels of immunoreactive erythropoietin in normal subjects and subjects with chronic lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Miller, M.E.; Garcia, J.F.; Cohen, R.A.; Cronkite, E.P.; Moccia, G.; Acevedo, J.

    1981-10-01

    Serum levels of immunoreactive erythropoietin (Ep) were measured in 48 normal male and female volunteers, ages 20-60 years, to establish a control value for Ep of 18.5 +/- 5.0 (mean +/- SD) mU/ml. Levels of the hormone were also measured sequentially over a 24 h period of time in an additional 17 normal volunteers with no diurnal variation. Diurnal levels of immunoreactive Ep were also measured in 30 subjects, with chronic lung disease. These patients, in contrast to normal subjects exhibited a diurnal variation in the level of immunoreactive Ep with peak levels occurring at midnight. The only variable measured which correlated with the serum immunoreactive Ep level in subjects with chronic lung disease was the level of carboxyhaemoglobin (P less than 0.02).

  13. A Study on Fasting Serum Gastrin level in Normal Subjects and Various Gastric Diseases by Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Duck; Lee, Heon Sil; Park, Seung Uk; Park, Sung Hwi; Lee, Chong Suk; Lee, Hak Choong [National Medical Center, Seoul (Korea, Republic of)

    1981-09-15

    The fasting serum gastrin levels were measured by radioimmunoassay in 32 normal healthy subjects without recognized gastrointestinal symptoms and 93 patients with various gastric diseases, who were visited of admitted to National Medical Center from February to June, 1981. The following results were obtained; 1) The fasting mean serum gastrin level in normal subjects was 55.9+-26.3 pg/m1, and there was no difference between male and female. 2) The gastrin levels in gastric and duodenal ulcer were 85.0+-28.4 and 76.0+-43.0 pg/ml respectively, and it's values were elevated as compared with normal subjects. In gastric ulcer, the gastrin level was elevated than that of duodenal ulcer, but no significant difference in each other. 3) The gastrin level in stomach cancer was 89.5+-42.2 pg/ml, and it's values were markedly elevated as compared with values in normal subjects. 4) The gastrin level in gastritis was 73.4+-37. 4 pg/ml, and it's values were elevated as compared with values in normal subjects. 5) The gastrin level in post-gastrectomy state was 50.3+-16.3 pg/ml, and it's values were slightly decreased as compared with values in normal subjects.

  14. A Study on Fasting Serum Gastrin level in Normal Subjects and Various Gastric Diseases by Radioimmunoassay

    International Nuclear Information System (INIS)

    Lee, Yong Duck; Lee, Heon Sil; Park, Seung Uk; Park, Sung Hwi; Lee, Chong Suk; Lee, Hak Choong

    1981-01-01

    The fasting serum gastrin levels were measured by radioimmunoassay in 32 normal healthy subjects without recognized gastrointestinal symptoms and 93 patients with various gastric diseases, who were visited of admitted to National Medical Center from February to June, 1981. The following results were obtained; 1) The fasting mean serum gastrin level in normal subjects was 55.9±26.3 pg/m1, and there was no difference between male and female. 2) The gastrin levels in gastric and duodenal ulcer were 85.0±28.4 and 76.0±43.0 pg/ml respectively, and it's values were elevated as compared with normal subjects. In gastric ulcer, the gastrin level was elevated than that of duodenal ulcer, but no significant difference in each other. 3) The gastrin level in stomach cancer was 89.5±42.2 pg/ml, and it's values were markedly elevated as compared with values in normal subjects. 4) The gastrin level in gastritis was 73.4±37. 4 pg/ml, and it's values were elevated as compared with values in normal subjects. 5) The gastrin level in post-gastrectomy state was 50.3±16.3 pg/ml, and it's values were slightly decreased as compared with values in normal subjects.

  15. A Study on Fasting Serum Gastrin level in Normal Subjects and Various Gastric Diseases by Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Duck; Lee, Heon Sil; Park, Seung Uk; Park, Sung Hwi; Lee, Chong Suk; Lee, Hak Choong [National Medical Center, Seoul (Korea, Republic of)

    1981-09-15

    The fasting serum gastrin levels were measured by radioimmunoassay in 32 normal healthy subjects without recognized gastrointestinal symptoms and 93 patients with various gastric diseases, who were visited of admitted to National Medical Center from February to June, 1981. The following results were obtained; 1) The fasting mean serum gastrin level in normal subjects was 55.9+-26.3 pg/m1, and there was no difference between male and female. 2) The gastrin levels in gastric and duodenal ulcer were 85.0+-28.4 and 76.0+-43.0 pg/ml respectively, and it's values were elevated as compared with normal subjects. In gastric ulcer, the gastrin level was elevated than that of duodenal ulcer, but no significant difference in each other. 3) The gastrin level in stomach cancer was 89.5+-42.2 pg/ml, and it's values were markedly elevated as compared with values in normal subjects. 4) The gastrin level in gastritis was 73.4+-37. 4 pg/ml, and it's values were elevated as compared with values in normal subjects. 5) The gastrin level in post-gastrectomy state was 50.3+-16.3 pg/ml, and it's values were slightly decreased as compared with values in normal subjects.

  16. Gold in semen: Level in seminal plasma and spermatozoa of normal ...

    African Journals Online (AJOL)

    K.P. Skandhan

    2016-07-01

    Jul 1, 2016 ... Gold level in sediment (spermatozoa) of normal was almost same as observed in its seminal plasma ... showed, gold was not detected in semen by Direct Couple ... Diffraction Analysis, revealed presence of gold throughout.

  17. Serum testosterone and gonadotropins levels in patients with premature ejaculation: A comparison with normal men

    Directory of Open Access Journals (Sweden)

    Mohammad G Mohseni

    2014-01-01

    Conclusion: Patients with PE have higher FT and FSH levels compared with normal men. The causative relationship between these entities and also the clinical importance of this finding has to be determined by more comprehensive studies.

  18. Simultaneous estimation of liquid and solid gastric emptying using radiolabelled egg and water in supine normal subjects.

    Science.gov (United States)

    Kris, M G; Yeh, S D; Gralla, R J; Young, C W

    1986-01-01

    To develop an additional method for the measurement of gastric emptying in supine subjects, 10 normal subjects were given a test meal containing 99Tc-labelled scrambled egg as the "solid" phase marker and 111In in tapwater as the marker for the "liquid" phase. The mean time for emptying 50% of the "solid" phase (t1/2) was 85 min and 29 min for the "liquid" phase. Three individuals were restudied with a mean difference between the two determinations of 10.8% for the "solid" phase and 6.5% for the "liquid" phase. Twenty-six additional studies attempted have been successfully completed in symptomatic patients with advanced cancer. This method provides a simple and reproducible procedure for the determination of gastric emptying that yields results similar to those reported for other test meals and can be used in debilitated patients.

  19. Normal spectral emissivity of selected liquid metals and improved thermophysical properties

    International Nuclear Information System (INIS)

    Pottlacher, G.; Seifter, A.

    2001-01-01

    Full Text: Emissivity measurements on several liquid metals up to temperatures of 6000 K have been successfully established by linking a laser polarimetry technique to our well-known method for performing high speed measurements of thermophysical properties on liquid metal samples during microsecond pulse-heating experiments. Thermophysical properties measured with our experimental setup include temperature dependencies of heat capacity, enthalpy, electrical resistivity, density, thermal diffusivity and thermal conductivity up to the end of the stable liquid phase. During grant P12775-PHY additionally to the above listened properties the measurement of the change of the polarization of laser light reflected from the surface during pulse heating was enabled and thus now the temperature dependence of spectral emissivity at 684.5 nm by methods of ellipsometry is derived also. Several liquid metals and alloys have been investigated within this grant and a review of the data obtained will be given here. (author)

  20. Impact of increasing alanine aminotransferase levels within normal range on incident diabetes

    OpenAIRE

    Chong-Shan Wang; Ting-Tsung Chang; Wei-Jen Yao; Shan-Tair Wang; Pesus Chou

    2012-01-01

    Abnormal alanine aminotransferase level (ALT) levels might be associated with type 2 diabetes, but whether higher ALT levels within the normal range predict the risk is unknown. Methods: We followed a community-based cohort of 3446 individuals who were ≥35 years old without diabetes and hepatitis B or C in southern Taiwan for 8 years (1997–2004) to study the risk for type 2 diabetes with different normal ALT levels. Results: Among the 337 incident diabetes cases, 16.0% were from those w...

  1. Concentration of High Level Radioactive Liquid Waste. Basic data acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Juvenelle, A.; Masson, M.; Garrido, M.H. [DEN/VRH/DRCP/SCPS/LPCP, BP 17171 - 30207 Bagnols sur Ceze Cedex (France)

    2008-07-01

    Full text of publication follows: In order to enhance its knowledge about the concentration of high level liquid waste (HLLW) from the nuclear fuel reprocessing process, a program of studies was defined by Cea. In a large field of acidity, it proposes to characterize the concentrated solution and the obtained precipitates versus the concentration factor. Four steps are considered: quantification of the salting-out effect on the concentrate acidity, acquisition of solubility data, precipitates characterisation versus the concentration factor through aging tests and concentration experimentation starting from simulated fission products solutions. The first results, reported here, connect the acidity of the concentrated solution to the concentration factor and allow us to precise the field of acidity (4 to 12 N) for the next experiments. In this field, solubility data of various elements (Ba, Sr, Zr...) are separately measured at room temperature, in nitric acid in a first time, then in the presence of various species present in medium (TBP, PO{sub 4}{sup 3-}). The reactions between these various elements are then investigated (formation of insoluble mixed compounds) by following the concentration cations in solution and characterising the precipitates. (authors)

  2. Low-level measurements by liquid scintillation counting

    International Nuclear Information System (INIS)

    Schoenhofer, F.

    1991-01-01

    Liquid scintillation counting has become a convenient tool for analysis of many beta- and alpha-emitters even in ultra low-level concentration ranges. Extremely low background is achieved in a commercially available counter by an active shielding and heavy lead shielding. Thus special time saving radiochemical separation processes could be designed. Extremely simple sample preparation techniques can be used. Counting time can be reduced and sample throughput enhanced. Also precision can be enhanced. From the author's research, several applications are discussed. They include: tritium in water without enrichment, tritium in urine (excretion analysis), carbon-14 in samples like alcohol or vinegar, Rn-222 in water and air, even gaseous Kr-85. A simple and fast method for Sr-90 in environmental samples and food has been developed and the Ra-226-concentration in water can be measured as low as 30 mBq/l without any chemical separation or enrichment. The instrument has been used successfully for screening purposes after the Chernobyl accident as well as for monitoring groundwater after a large scale contamination in Lower Austria. Using a 'gross-beta-measurement' effluents from a nuclear installation are monitored, clearly showing advantages over traditional methods. α-β-discrimination reduces the background for alpha emitters to practically zero. Examples from the determination of Ra-226 in water are shown

  3. Association of Tumor Growth Factor-? and Interferon-? Serum Levels with Insulin Resistance in Normal Pregnancy

    OpenAIRE

    Jahromi, Abdolreza Sotoodeh; Sanie, Mohammad Sadegh; Yusefi, Alireza; Zabetian, Hassan; Zareian, Parvin; Hakimelahi, Hossein; Madani, Abdolhossien; Hojjat-Farsangi, Mohammad

    2015-01-01

    Pregnancy is related to change in glucose metabolism and insulin production. The aim of our study was to determine the association of serum IFN-? and TGF-? levels with insulin resistance during normal pregnancy. This cross sectional study was carried out on 97 healthy pregnant (in different trimesters) and 28 healthy non-pregnant women. Serum TGF-? and IFN-? level were measured by ELISA method. Pregnant women had high level TGF-? and low level IFN-? as compared non-pregnant women. Maternal se...

  4. Sheath liquid interface for the coupling of normal-phase liquid chromatography with electrospray mass spectrometry and its application to the analysis of neoflavonoids.

    Science.gov (United States)

    Charles, Laurence; Laure, Frédéric; Raharivelomanana, Phila; Bianchini, Jean-Pierre

    2005-01-01

    A novel interface that allows normal-phase liquid chromatography to be coupled with electrospray ionization (ESI) is reported. A make-up solution of 60 mM ammonium acetate in methanol, infused at a 5 microl min(-1) flow-rate at the tip of the electrospray probe, provides a sheath liquid which is poorly miscible with the chromatographic effluent, but promotes efficient ionization of the targeted analytes. Protonated molecules generated in the ESI source were subjected to tandem mass spectrometric experiments in a triple-quadrupole mass spectrometer. The main fragmentation reactions were characterized for each analyte and specific mass spectral transitions were used to acquire chromatographic data in the multiple reaction monitoring detection mode. Results obtained during optimization of the sheath liquid composition and flow-rate suggest that the electrospray process was mainly under the control of the make-up solution, and that it forms an external charged layer around a neutral chromatographic mobile phase core. This sheath liquid interface was implemented for the analysis of some neoflavonoid compounds and its performance was evaluated. Limits of detection were established for calophillolide, inophyllum B, inophyllum P and inophyllum C at 100, 25, 15 and 100 ng ml(-1), respectively.

  5. Return and Liquidity Relationships on Market and Accounting Levels in Brazil

    OpenAIRE

    Perobelli,Fernanda Finotti Cordeiro; Famá,Rubens; Sacramento,Luiz Claudio

    2016-01-01

    ABSTRACT This article discusses profitability-liquidity relationships on accounting and market levels for 872 shares of publicly-traded Brazilian companies, observed between 1994 and 2013. On the market level, the assumption is that share liquidity is able to reduce some of the risks incurred by investors, making them more willing to pay a higher price for liquid shares, which would lower expected market returns. On the accounting level, the basic hypothesis argues that a firm's holding more ...

  6. Higher TSH Levels Within the Normal Range Are Associated With Unexplained Infertility.

    Science.gov (United States)

    Orouji Jokar, Tahereh; Fourman, Lindsay T; Lee, Hang; Mentzinger, Katherine; Fazeli, Pouneh K

    2018-02-01

    Unexplained infertility (UI), defined as the inability to conceive after 12 months of unprotected intercourse with no diagnosed cause, affects 10% to 30% of infertile couples. An improved understanding of the mechanisms underlying UI could lead to less invasive and less costly treatment strategies. Abnormalities in thyroid function and hyperprolactinemia are well-known causes of infertility, but whether thyrotropin (TSH) and prolactin levels within the normal range are associated with UI is unknown. To compare TSH and prolactin levels in women with UI and women with a normal fertility evaluation except for an azoospermic or severely oligospermic male partner. Cross-sectional study including women evaluated at a large academic health system between 1 January 2000 and 31 December 2012 with normal TSH (levels within the normal range of the assay and ≤5 mIU/L) and normal prolactin levels (≤20 ng/mL) and either UI (n = 187) or no other cause of infertility other than an azoospermic or severely oligospermic partner (n = 52). TSH and prolactin. Women with UI had significantly higher TSH levels than controls [UI: TSH 1.95 mIU/L, interquartile range: (1.54, 2.61); severe male factor: TSH 1.66 mIU/L, interquartile range: (1.25, 2.17); P = 0.003]. This finding remained significant after we controlled for age, body mass index, and smoking status. Nearly twice as many women with UI (26.9%) had a TSH ≥2.5 mIU/L compared with controls (13.5%; P < 0.05). Prolactin levels did not differ between the groups. Women with UI have higher TSH levels compared with a control population. More studies are necessary to determine whether treatment of high-normal TSH levels decreases time to conception in couples with UI. Copyright © 2017 Endocrine Society

  7. Partitioning of high level liquid waste: experiences in plant level adoption

    International Nuclear Information System (INIS)

    Manohar, Smitha; Kaushik, C.P.

    2016-01-01

    High Level Radioactive Wastes are presently vitrified in borosilicate matrices in all our back end facilities in our country. This is in accordance with internationally endorsed methodology for the safe management of high level radioactive wastes. Recent advancements in the field of partitioning technology in our group, has presented us with an opportunity to have a fresh perspective on management of high level liquid radioactive wastes streams, that emanate from reprocessing operations. This paper will highlight our experiences with respect to both partitioning studies and vitrification practices, with a focus on waste volume reduction for final disposal. Incorporation of this technique has led to the implementation of the concept of recovering wealth from waste, a marked decrease on the load of disposal in deep geological repositories and serve as a step towards the vision of transmutation of long lived radionuclides

  8. Selection of liquid-level monitoring method for the Oak Ridge National Laboratory inactive liquid low-level waste tanks, remedial investigation/feasibility study

    International Nuclear Information System (INIS)

    1994-11-01

    Several of the inactive liquid low-level waste (LLLW) tanks at Oak Ridge National Laboratory contain residual wastes in liquid or solid (sludge) form or both. A plan of action has been developed to ensure that potential environmental impacts from the waste remaining in the inactive LLLW tank systems are minimized. This document describes the evaluation and selection of a methodology for monitoring the level of the liquid in inactive LLLW tanks. Criteria are established for comparison of existing level monitoring and leak testing methods; a preferred method is selected and a decision methodology for monitoring the level of the liquid in the tanks is presented for implementation. The methodology selected can be used to continuously monitor the tanks pending disposition of the wastes for treatment and disposal. Tanks that are empty, are scheduled to be emptied in the near future, or have liquid contents that are very low risk to the environment were not considered to be candidates for installing level monitoring. Tanks requiring new monitoring equipment were provided with conductivity probes; tanks with existing level monitoring instrumentation were not modified. The resulting data will be analyzed to determine inactive LLLW tank liquid level trends as a function of time

  9. Higher Levels of Albuminuria within the Normal Range Predict Incident Hypertension

    OpenAIRE

    Forman, John P.; Fisher, Naomi D.L.; Schopick, Emily L.; Curhan, Gary C.

    2008-01-01

    Higher levels of albumin excretion within the normal range are associated with cardiovascular disease in high-risk individuals. Whether incremental increases in urinary albumin excretion, even within the normal range, are associated with the development of hypertension in low-risk individuals is unknown. This study included 1065 postmenopausal women from the first Nurses’ Health Study and 1114 premenopausal women from the second Nurses’ Health Study who had an albumin/creatinine ratio

  10. Normal levels of plasma FSH and LH in the menstrual cycle as determined by radioimmunoassay

    International Nuclear Information System (INIS)

    Lemgruber, I.; Pinto, J.C.M.; Linhares, E.; Granafer, A.

    1981-01-01

    The biological methods were not able to establish adequately the separate determination of FSH and LH. The introduction of radioimmunoassay had allowed the identification of plasma FSH and LH for the purpose of routine clinical use. The utilization of commercial kits, however, obliges each laboratory to have normal levels of his own. Such is the finality of this work, studying samples from 200 normal women, hospitalized for surgical reasons and having not any endocrinological problem. (author) [pt

  11. Comparison of plasma endothelin levels between osteoporotic, osteopenic and normal subjects

    Directory of Open Access Journals (Sweden)

    Biçimoğlu Ali

    2005-09-01

    Full Text Available Abstract Background It has been demonstrated that endothelins (ET have significant roles in bone remodeling, metabolism and physiopathology of several bone diseases. We aimed to investigate if there was any difference between the plasma ET levels of osteoporotic patients and normals. Methods 86 patients (70 women and 16 men with a mean age of 62.6 (ranges: 51–90 years were included in this study. Patients were divided into groups of osteoporosis, osteopenia and normal regarding reported T scores of DEXA evaluation according to the suggestions of World Health Organization. According to these criteria 19, 43 and 24 were normal, osteopenic and osteoporotic respectively. Then total plasma level of ET was measured in all patients with monoclonal antibody based sandwich immunoassay (EIA method. One-way analysis of variance test was used to compare endothelin values between normals, osteopenics and osteoporotics. Results Endothelin total plasma level in patients was a mean of 98.36 ± 63.96, 100.92 ± 47.2 and 99.56 ± 56.6 pg/ml in osteoporotic, osteopenic and normal groups respectively. The difference between groups was not significant (p > 0.05. Conclusion No significant differences in plasma ET levels among three groups of study participants could be detected in this study.

  12. A Continuous Liquid-Level Sensor for Fuel Tanks Based on Surface Plasmon Resonance

    Directory of Open Access Journals (Sweden)

    Antonio M. Pozo

    2016-05-01

    Full Text Available A standard problem in large tanks at oil refineries and petrol stations is that water and fuel usually occupy the same tank. This is undesirable and causes problems such as corrosion in the tanks. Normally, the water level in tanks is unknown, with the problems that this entails. We propose herein a method based on surface plasmon resonance (SPR to detect in real time the interfaces in a tank which can simultaneously contain water, gasoline (or diesel and air. The plasmonic sensor is composed of a hemispherical glass prism, a magnesium fluoride layer, and a gold layer. We have optimized the structural parameters of the sensor from the theoretical modeling of the reflectance curve. The sensor detects water-fuel and fuel-air interfaces and measures the level of each liquid in real time. This sensor is recommended for inflammable liquids because inside the tank there are no electrical or electronic signals which could cause explosions. The sensor proposed has a sensitivity of between 1.2 and 3.5 RIU−1 and a resolution of between 5.7 × 10−4 and 16.5 × 10−4 RIU.

  13. Comparison of 25-hydroxyvitamin D and Calcium Levels between Polycystic Ovarian Syndrome and Normal Women

    Directory of Open Access Journals (Sweden)

    Ashraf Moini

    2015-04-01

    Full Text Available Background: Given the relationship of vitamin D deficiency with insulin resistance syndrome as the component of polycystic ovary syndrome (PCOS, the main aim of this study was to compare serum level of 25- hydroxyvitamin D [25(OHD] between PCOS patients and normal individuals. Materials and Methods: A cross sectional study was conducted to compare 25(OHD level between117 normal and 125 untreated PCOS cases at our clinic in Arash Hospital, Tehran, Iran, during 2011-2012. The obtained levels of 25(OHD were classified as follows: lower than 25 nmol/ml as severe deficiency, between 25-49.9 nmol/ml as deficiency, 50-74.9 nmol/ml as insufficiency, and above 75 nmol/ml asnormal. In addition, endocrine and metabolic variables were evaluated. Results: Among PCOS patients, our findings shows 3(2.4% normal, 7(5.6% with insufficiency, 33(26.4% with deficiency and 82(65.6% with severe deficiency, whereas in normal participants, 5(4.3% normal, 4(3.4% with insufficiency, 28(23.9% with deficiency and 80(68.4% with severe deficiency. Comparison of 25(OHD level between two main groups showed no significant differences (p= 0.65. Also, the calcium and 25(OHD levels had no significant differences in patients with overweight (p=0.22 and insulin resistance (p=0.64. But we also found a relationship between 25(OHD level and metabolic syndrome (p=0.01. Furthermore, there was a correlation between 25(OHD and body mass index (BMI in control group (p=0.01, while the C-reactive protein (CRP level was predominantly higher in PCOS group (p<0.001. Conclusion: Although the difference of 25(OHD level between PCOS and healthy women is not significant, the high prevalence of 25(OHD deficiency is a real alarm for public health care system and may influence our results.

  14. Positive ion mobilities in normal liquid 3He at ultralow temperatures

    International Nuclear Information System (INIS)

    Alexander, P.W.

    1978-11-01

    The mobility has been measured of positive ions in liquid 3 he in the range 2.5 mK 3 sub(m)/sup(V) 5 sub(m)/sup(V). The effects of 500 p.p.m. 4 He in the 3 He were investigated. It was found that, at low temperatures, several stable ion species could be produced for 3 He pressures of 23 bar and above and, between 25 mK and 60 mK, time dependent conversion from one species of ion to another was observed at all pressures. The creation mechanism, mobility and stability of multiple positive ions were studied. Possible explanations of the phenomena are discussed. The measured drift field dependence of mobility is used to test the quasiparticle scattering model assumed for the liquid. (U.K.)

  15. Freezing of a modulated liquid: The superionic-to-normal transition of strontium chloride

    International Nuclear Information System (INIS)

    Rovere, M.; Tosi, M.P.; Trieste Univ.

    1985-05-01

    The anionic component in SrCl 2 near melting is treated as a modulated liquid in the periodic potential of the sublattice of cations. With decreasing temperature from the melting point, we find a diffuse disorder-order phase transition. The calculated behaviours of the order parameter and of thermodynamic properties approximate those observed for SrCl 2 across its superionic transition. (author)

  16. Normal coordinate treatment of liquid water and calculation of vapor pressure isotope effects

    International Nuclear Information System (INIS)

    Gellai, B.; Van Hook, W.A.

    1983-01-01

    A vibrational analysis of liquid water is reported, assuming a completely hydrogen-bonded network with continuously varying strengths of the hydrogen bonds. Frequency distribution calculations are made for intramolecular stretching and bending modes and for the intramolecular frequency region. The calculated distributions are compared with the experimental spectroscopic ones. As another test, vapor pressure isotope effects are calculated from the theoretical distributions for some isotopic water molecules. Results are compared with those of other authors obtained from a mixture model. (author)

  17. Contingency plan for the Oak Ridge National Laboratory liquid low-level waste system

    International Nuclear Information System (INIS)

    DePaoli, S.M.; Ferrada, J.J.; Abraham, T.J.; Brown, C.H.; Lin, K.H.

    1989-12-01

    Oak Ridge National Laboratory (ORNL) is one of the major Department of Energy (DOE) facilities that performs various research and development (R ampersand D) activities. Liquid low-level waste (LLLW) is generated in the course of this work. The primary objective of this task is to develop specific plans of action to be implemented, in the event that the storage space for the LLLW concentrate should approach the minimum value in the operational flexibility range or a problem should develop concerning storage space available for dilute LLLW. This report considers contingency plans/options in the light of six different scenarios, including ''normal operation'' and five others. Evaluation and prioritization of the options were carried out separately for each case. Brief discussions of these scenarios and contingency plans/options are presented. 20 refs., 14 figs., 14 tabs

  18. Synuclein gamma predicts poor clinical outcome in colon cancer with normal levels of carcinoembryonic antigen

    Directory of Open Access Journals (Sweden)

    Xing Xiaofang

    2010-07-01

    Full Text Available Abstract Background Synuclein gamma (SNCG, initially identified as a breast cancer specific gene, is aberrantly expressed in many different malignant tumors but rarely expressed in matched nonneoplastic adjacent tissues. In this study, we investigated the prognostic potential of SNCG in colon cancer particularly in the patients with normal carcinoembryonic antigen (CEA levels. Methods SNCG levels were assessed immunohistochemically in cancer tissues from 229 colon adenocarcinoma patients with a mean follow-up of 44 months. Correlations between SNCG levels and clinicopathologic features, preoperative serum CEA level, and clinical outcome were analyzed statistically using SPSS. Results SNCG levels in colon adenocarcinoma were closely associated with intravascular embolus and tumor recurrence but independent of preoperative serum CEA levels. SNCG expression was an independent prognostic factor of a shorter disease-free survival (DFS and overall survival (OS (P P = 0.001, P = 0.001, 0.002 for 97 patients with normal preoperative serum CEA level. Conclusions Our results suggest for the first time that SNCG is a new independent predicator for poor prognosis in patients with colon adenocarcinoma, including those with normal CEA levels. Combination of CEA with SNCG improves prognostic evaluation for patients with colon adenocarcinoma.

  19. Esophageal contractions, bolus transit and perception of transit after swallows of liquid and solid boluses in normal subjects

    Directory of Open Access Journals (Sweden)

    Juciléia Dalmazo

    2012-12-01

    Full Text Available CONTEXT: Esophageal dysphagia is the sensation that the ingested material has a slow transit or blockage in its normal passage to the stomach. It is not always associated with motility or transit alterations. OBJECTIVES: To evaluate in normal volunteers the possibility of perception of bolus transit through the esophagus after swallows of liquid and solid boluses, the differences in esophageal contraction and transit with these boluses, and the association of transit perception with alteration of esophageal contraction and/or transit. METHODS: The investigation included 11 asymptomatic volunteers, 4 men and 7 women aged 19-58 years. The subjects were evaluated in the sitting position. They performed swallows of the same volume of liquid (isotonic drink and solid (macaroni boluses in a random order and in duplicate. After each swallow they were asked about the sensation of bolus passage through the esophagus. Contractions and transit were evaluated simultaneously by solid state manometry and impedance. RESULTS: Perception of bolus transit occurred only with the solid bolus. The amplitude and area under the curve of contractions were higher with swallows of the solid bolus than with swallows of the liquid bolus. The difference was more evident in swallows with no perception of transit (n = 12 than in swallows with perception (n = 10. The total bolus transit time was longer for the solid bolus than for the liquid bolus only with swallows followed by no perception of transit. CONCLUSION: The results suggest that the perception of esophageal transit may be the consequence of inadequate adaptation of esophageal transit and contraction to the characteristics of the swallowed bolus.

  20. Comparison of Serum Homocystein and Folic Acid Levels in Gestational Diabetes with Normal Pregnancy

    Directory of Open Access Journals (Sweden)

    F. Movahed

    2015-07-01

    Full Text Available Introduction & Objective: High levels of homocystein are a risk factor for insulin resistance, diabetes mellitus and cardio-vascular complications. This study was done to assess serum homocystein and folic acid levels and their relationship in women with gestational diabetes and compare them with normal pregnant women. Materials & Methods: This analytic epidemiologic case-control study was performed in Qazvin Kosar hospital in 2013-2015. 120 singleton pregnant women with 24-28 weeks of gestation according to 2-hour 75g oral glucose tolerance test were assigned to two groups; gestational diabetes (n=60, and normal pregnancy (n=60. Serum homocystein and folic acid levels were measured in two groups. Data were analyzed with statistical t-test and correlation method. Results: In gestational diabetes serum homocystein level was significantly higher (P<0.001 and folic acid was significantly lower (P<0.001 than normal pregnancy group .No relation-ship was observed between serum homocystein and serum folate. In both groups, serum folic acid was significantly related to fasting blood sugar. This relationship was inverse in gesta-tional diabetes group (P<0.001, r = - 0.512 and direct in normal pregnancy group (P=0.001 r =0.417. Conclusion: It seems folic acid has a role in regulation of serum homocystein level and blood sugar.(Sci J Hamadan Univ Med Sci 2015; 22 (2: 93-98

  1. On-line comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for preparative isolation of Peucedanum praeruptorum.

    Science.gov (United States)

    Wang, Xin-Yuan; Li, Jia-Fu; Jian, Ya-Mei; Wu, Zhen; Fang, Mei-Juan; Qiu, Ying-Kun

    2015-03-27

    A new on-line comprehensive preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was developed for the separation of complicated natural products. It was based on the use of a silica gel packed medium-pressure column as the first dimension and an ODS preparative HPLC column as the second dimension. The two dimensions were connected with normal-phase (NP) and reversed-phase (RP) enrichment units, involving a newly developed airflow assisted adsorption (AAA) technique. The instrument operation and the performance of this NPLC × RPLC separation method were illustrated by gram-scale isolation of ethanol extract from the roots of Peucedanum praeruptorum. In total, 19 compounds with high purity were obtained via automated multi-step preparative separation in a short period of time using this system, and their structures were comprehensively characterized by ESI-MS, (1)H NMR, and (13)C NMR. Including two new compounds, five isomers in two groups with identical HPLC and TLC retention values were also obtained and identified by 1D NMR and 2D NMR. This is the first report of an NPLC × RPLC system successfully applied in an on-line preparative process. This system not only solved the interfacing problem of mobile-phase immiscibility caused by NP and RP separation, it also exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Determination of molybdenum in various materials by normal-phase liquid chromatography using N-benzoyl-N-phenylhydroxylamine

    International Nuclear Information System (INIS)

    Bagur, Gracia; Sanchez-Vinas, Mercedes; Gazquez, Domingo

    1995-01-01

    A normal-phase liquid chromatographic method for the selective determination of molybdenum with N-benzoyl-N-phenylhydroxylamine is described. The molybdenum(VI) complex was preconcentrated by extraction into chloroform and injected onto a nitrile column for chromatography. The mobile phase was a 0.075 M solution of reagent in chloroform (stabilized with amylene). The detection limit for molybdenum by the proposed method was 0.88 ng for a phase volume ratio of 20:1 (aqueous to organic). Molybdenum has been determined in several samples with satisfactory accuracy and precision

  3. Profiling of lipid species by normal-phase liquid chromatography, nanoelectrospray ionization, and ion trap-orbitrap mass spectrometry

    DEFF Research Database (Denmark)

    Sokol, Elena; Almeida, Reinaldo; Hannibal-Bach, Hans Kristian

    2013-01-01

    Detailed analysis of lipid species can be challenging due to their structural diversity and wide concentration range in cells, tissues, and biofluids. To address these analytical challenges, we devised a reproducible, sensitive, and integrated lipidomics workflow based on normal-phase liquid......) routine for characterizing the fatty acid moieties of identified lipid species. We benchmarked the performance of the workflow by characterizing the chromatographic properties of the LC-MS system for general lipid analysis. In addition, we demonstrate the efficacy of the workflow by reporting a study...

  4. [Relationship between the Mandarin acceptable noise level and the personality traits in normal hearing adults].

    Science.gov (United States)

    Wu, Dan; Chen, Jian-yong; Wang, Shuo; Zhang, Man-hua; Chen, Jing; Li, Yu-ling; Zhang, Hua

    2013-03-01

    To evaluate the relationship between the Mandarin acceptable noise level (ANL) and the personality trait for normal-hearing adults. Eighty-five Mandarin speakers, aged from 21 to 27, participated in this study. ANL materials and the Eysenck Personality Questionnaire (EPQ) questionnaire were used to test the acceptable noise level and the personality trait for normal-hearing subjects. SPSS 17.0 was used to analyze the results. ANL were (7.8 ± 2.9) dB in normal hearing participants. The P and N scores in EPQ were significantly correlated with ANL (r = 0.284 and 0.318, P 0.05). Listeners with higher ANL were more likely to be eccentric, hostile, aggressive, and instabe, no ANL differences were found in listeners who were different in introvert-extravert or lying.

  5. Sleep-wake stability in narcolepsy patients with normal, low and unmeasurable hypocretin levels

    DEFF Research Database (Denmark)

    Hansen, Mathias Hvidtfelt; Kornum, Birgitte Rahbek; Jennum, Poul

    2017-01-01

    movement (REM) sleep, and the occurrence of sleep onset REM (SOREM) in the nocturnal polysomnography were also measured. RESULTS: Participants with undetectable hypocretin-1 levels had significantly higher frequencies of transitions than controls and those with normal hypocretin-1 levels. Participants...... hypocretin-1 levels in particular, but also low hypocretin-1 levels, were associated with a less stable phenotype featuring more sleep state transitions and SOREM episodes. In addition, there was a distinction between nocturnal and diurnal REM sleep in hypocretin-deficient participants, expressed...... as increased diurnal REM sleep, which was not reflected in nocturnal sleep....

  6. Data on copper level in the blood of patients with normal and abnormal angiography

    Directory of Open Access Journals (Sweden)

    Leila Amiri

    2016-12-01

    Full Text Available In this data article, we measured the levels of copper in the blood of patients undergoing coronary angiography. The samples were taken from patients with cardiovascular disease in Bushehr׳s university hospital, Iran. Patients were divided in two groups: normal angiography and abnormal angiography. After the chemical digestion of samples, the concentration levels of Cu in both groups were determined by using inductively coupled plasma optical spectrometry (ICP-OES.

  7. Sleep-wake stability in narcolepsy patients with normal, low and unmeasurable hypocretin levels.

    Science.gov (United States)

    Hansen, Mathias Hvidtfelt; Kornum, Birgitte Rahbek; Jennum, Poul

    2017-06-01

    To compare diurnal and nocturnal electrophysiological data from narcolepsy patients with undetectable (110 pg/mL) cerebrospinal fluid (CSF) hypocretin-1 levels. A total of 109 narcolepsy patients and 37 controls were studied; all had available CSF hypocretin-1 measurements. The sleep laboratory studies were conducted between 2008 and 2014. The study retrospectively examined measurements of sleep stage transitions in diurnal and nocturnal continuous polysomnography. The percentage distribution of time awake and rapid eye movement (REM) sleep, and the occurrence of sleep onset REM (SOREM) in the nocturnal polysomnography were also measured. Participants with undetectable hypocretin-1 levels had significantly higher frequencies of transitions than controls and those with normal hypocretin-1 levels. Participants with low hypocretin-1 levels showed more transitions than controls and, in some cases, also more than those with normal hypocretin-1. Participants with normal hypocretin-1 failed to show any significant difference from the controls, except in the overall diurnal transitions. Undetectable hypocretin-1 levels in particular, but also low hypocretin-1 levels, were associated with a less stable phenotype featuring more sleep state transitions and SOREM episodes. In addition, there was a distinction between nocturnal and diurnal REM sleep in hypocretin-deficient participants, expressed as increased diurnal REM sleep, which was not reflected in nocturnal sleep. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Biphasic solid and liquid gastric emptying in normal control subjects and diabetic patients with continuous acquisition in the left anterior oblique view

    International Nuclear Information System (INIS)

    Ziessman, H.A.; Fahey, F.H.; Herring, C.D.; Deschner, W.K.; Collen, M.J.; Vigersky, R.A.

    1989-01-01

    This paper reports solid and liquid gastric emptying (GE) studied in 10 normal controls and 20 diabetics with symptoms of gastroparesis. After the ingestion of a Tc-99m SC egg sandwich and In-lll DTPA in water, 90 1-minute frames were acquired in the left anterior oblique view. Solid GE had a lag phase in all cases and then emptied linearly. Compared with normal controls, diabetics had delayed GE and delayed lag phase (P< .05). Liquid GE was exponential with no lag phase. Biexponential liquid emptying with an early fast component followed by a second slower one was seen in 60% of normal controls and 70% of diabetics. The slower component of liquid GE correlated with the solid GE rate (normal controls, r= .826; diabetics, r = .885)

  9. Design, Development and Testing of a Semi Cylindrical Capacitive Sensor for Liquid Level Measurement

    Directory of Open Access Journals (Sweden)

    Sagarika PAL

    2010-05-01

    Full Text Available In the present paper a low cost noncontact semi cylindrical capacitive type liquid level sensor has been designed, developed and tested. The semi cylindrical capacitive sensor consisting of two thin semi cylindrical metal plates separated by a gap distance and mounted around a non conducting storage tank, has been used to measure the liquid level in the tank. The measured capacitance variation with variation of liquid level is linear and obtained in the nano farad range which again has been converted into voltage variation by using proper signal conditioning circuit. Since the sensor is noncontact type it can be used for both conducting and non conducting type of liquid contained within a non conducting tank. For converting the capacitance variation in to voltage variation a series R-L-C resonating circuit has been used instead of conventional bridge circuit. Experimental results confirm the satisfactory performance of the sensor for liquid level measurement.

  10. Return and Liquidity Relationships on Market and Accounting Levels in Brazil

    Directory of Open Access Journals (Sweden)

    Fernanda Finotti Cordeiro Perobelli

    2016-08-01

    Full Text Available ABSTRACT This article discusses profitability-liquidity relationships on accounting and market levels for 872 shares of publicly-traded Brazilian companies, observed between 1994 and 2013. On the market level, the assumption is that share liquidity is able to reduce some of the risks incurred by investors, making them more willing to pay a higher price for liquid shares, which would lower expected market returns. On the accounting level, the basic hypothesis argues that a firm's holding more liquid assets is related to a conservative investment policy, possibly reducing accounting returns for shareholders. Under the assumption of financial constraint, however, more accounting liquidity would allow positive net present value investments to be carried out, increasing future accounting returns, which would positively affect market liquidity and share prices in an efficient market, resulting in a lower market risk/expected return premium. Under the assumption of no financial constraint, however, more accounting liquidity would only represent a carry cost, compromising future accounting returns, which would adversely affect market liquidity and share prices and result in a higher market risk/expected return premium. Among the hypotheses, the presence of a negative market liquidity premium was verified in Brazil, with shares that traded more exhibiting a higher expected market return. On the margins of the major theories on the subject, only two negative relationships between excess accounting liquidity and market liquidity and accounting return, supporting the carry cost assumption for financially unconstrained firms, were verified. In terms of this paper's contributions, there is the analysis, unprecedented in Brazil as far as is known, of the relationship between liquidity and return on market and accounting levels, considering the financial constraint hypothesis to which the firms are subject.

  11. Competition, liquidity and stability: international evidence at the bank and systemic levels

    OpenAIRE

    Nguyen, Thi Ngoc My

    2017-01-01

    This thesis investigates the impact of market power on bank liquidity; the association between competition and systemic liquidity; and whether the associations between liquidity and stability at both bank- and systemic- levels are affected by competition. The first research question is explored in the context of 101 countries over 1996-2013 while the second and the third, which require listed banks, use a smaller sample of 32 nations during 2001-2013. The Panel Least Squares and the system Ge...

  12. Sex differences in plasma homovanillic acid levels in schizophrenia and normal controls: relation to neuroleptic resistance.

    Science.gov (United States)

    Sumiyoshi, T; Hasegawa, M; Jayathilake, K; Meltzer, H Y

    1997-03-01

    Plasma homovanillic acid (pHVA) levels were compared in a large number of neuroleptic-resistant and -responsive schizophrenic patients (male/female = 161/46) and normal controls (67/27), and correlated with various measures of psychopathology. Psychopathology was evaluated with the brief psychiatric rating scale, the Schedule for Affective Disorders and Schizophrenia-Change version (SADS-C) and SADS-C Global Assessment Scale, the Scale for Assessment of Negative Symptoms, the Scale for Assessment of Positive Symptoms (SAPS), and the Quality of Life Scale. No significant differences in pHVA levels between neuroleptic-resistant (n = 104) or -responsive (n = 103) schizophrenic patients, and normal controls, were found; however, there was a main effect for sex, due to higher pHVA levels in women than men. There were no diagnosis x gender or age effects on pHVA levels. No significant correlations were observed between psychopathology ratings and baseline pHVA levels, except with the Hallucinations subscale of SAPS in neuroleptic-responsive patients. Neither duration of neuroleptic washout nor plasma prolactin levels correlated with pHVA levels. Further studies on the origin and significance of the gender difference in pHVA are indicated.

  13. Epidemiological studies in the high and normal level radiation areas of Kerala

    International Nuclear Information System (INIS)

    Koya, P.K.M.

    2012-01-01

    High and normal level natural radiation areas of Kerala give unique opportunities to estimate the risk, if any, of chronic low dose exposure by direct epidemiological studies on human beings. Studies in the area are being carried out by Low Level Radiation Research Laboratory of Bhabha Atomic Research Centre in collaboration with Departments of Health and Family Welfare/Social Welfare of the Government of Kerala and local post graduate colleges. To assess the role of chronic low dose exposure in the induction/transmission of chromosomal alterations across generations, hospital based cytogenetic studies on newborns was carried out to estimate and compare the frequency of chromosomal aberrations and karyotypes anomalies in the high (areas with radiation dose of more than 1.50 mGy/year) and normal (areas with radiation dose of 1.50 mR/year or less) level radiation areas. A total of 1,267,788 metaphases from 27,295 (9,64,390 cells from 17,298 newborns of high and 3,03,398 cells from 9,997 newborns of normal level radiation areas) newborns was screened

  14. Radioimmunoassay of erythropoietin: circulating levels in normal and polycythemic human beings

    International Nuclear Information System (INIS)

    Garcia, J.F.; Ebbe, S.N.; Hollander, L.; Cutting, H.O.; Miller, M.E.; Cronkite, E.P.

    1982-01-01

    Techniques are described in detail for the RIA of human Ep in unextracted plasma or serum. With 100 μl of sample, the assay is sensitive at an Ep concentration of approximately 4 mU/ml, and when required, the sensitivity can be increased to 0.4 mU/ml, a range considerably less than the concentration observed in normal human beings. This is approximately 100 times more sensitive than existing in vivo bioassays for this hormone. Studies concerned with the validation of the Ep RIA show a high degree of correlation with the polycythemic mouse bioassay. Dilutions of a variety of human serum samples show a parallel relationship with the standard reference preparation for Ep. Validation of the RIA is further confirmed by observations of appropriate increases or decreases of circulating Ep levels in physiological and clinical conditions known to be associated with stimulation or suppression of Ep secretion. Significantly different mean serum concentrations of 17.2 mU/ml for normal male subjects and 18.8 mU/ml for normal female subjects were observed. Mean plasma Ep concentrations in patients with polycythemia vera are significantly decreased, and those of patients with secondary polycythemia are significantly increased as compared to plasma levels in normal subjects. These results demonstrate an initial practical value of the Ep RA in the hematology clinic, which will most certainly be expanded with its more extensive use

  15. Study on Calculation of Liquid Level And Storage of Tanks for LNG-fueled Vessels

    Science.gov (United States)

    Li, Kun; Wang, Guoqing; Liu, Chang

    2018-01-01

    As the ongoing development of the application of LNG as a clean energy in waterborne transport industry, the fleet scale of LNG-fueled vessels enlarged and the safety operation has attracted more attention in the industry. Especially the accurate detection of liquid level of LNG tanks is regarded as an important issue to ensure a safe and stable operation of LNG-fueled ships and a key parameter to keep the proper functioning of marine fuel storage system, supply system and safety control system. At present, detection of LNG tank liquid level mainly adopts differential pressure detection method. Liquid level condition could be found from the liquid level reference tables. However in practice, since LNG-fueled vessels are generally not in a stationary state, liquid state within the LNG tanks will constantly change, the detection of storage of tanks only by reference to the tables will cause deviation to some extent. By analyzing the temperature under different pressure, the effects of temperature change on density and volume integration calculation, a method of calculating the liquid level and storage of LNG tanks is put forward making the calculation of liquid level and actual storage of LNG tanks more accurately and providing a more reliable basis for the calculation of energy consumption level and operation economy for LNG-fueled vessels.

  16. Study of AFP level in the blood serum of the 2223 normal pregnant women

    International Nuclear Information System (INIS)

    Wang Yunhui; Huo Tongshu; Ji Changqing; Mei Nan; Zhang Tao

    1993-01-01

    The authors have reported AFP level in the blood serum of 2223 normal pregnant women in different semesters by RIA method. All the data were made by statistical analysis. The result shows that the AFP level is normal during the first 12 weeks of pregnancy. Then, it gradually increases from the 13th week and reaches its maximum (184.6 +- 74.6 μg/l) at 32nd week. Later on it tends to decrease slowly, but still remains over 100 μg/l in parturition period. Therefore, it is suggested that AFP in pregnant women has substantial difference and regularity between different semesters but without any significant correlation with their ages

  17. Tobacco-Specific Nitrosamines in Electronic Cigarettes: Comparison between Liquid and Aerosol Levels

    Directory of Open Access Journals (Sweden)

    Konstantinos E. Farsalinos

    2015-07-01

    Full Text Available Introduction: Although electronic cigarette (EC liquids contain low levels of tobacco-specific nitrosamines (TSNAs, studies evaluating the levels emitted to the aerosol are scarce. The purpose of this study was to compare the levels of TSNAs between liquids and generated aerosol. Methods: Three EC liquids were obtained from the market. An additional (spiked sample was prepared by adding known amounts of standard TSNAs solutions to one of the obtained liquids. N-nitrosonornicotine (NNN, N-nitrosoanatabine (NAT, N-nitrosoanabasine (NAB and 4-(methylnitrosamino1-(3-pyridyl-1-butanone (NNK were measured. Three 100-puff sets from each liquid were trapped in filter pads and were subsequently analyzed for the presence of TSNAs. The expected levels of TSNAs (calculated based on the liquid consumption were compared with the measured levels in the aerosol. Results: Only NAB was found at trace levels in two commercial liquids (1.2 and 2.3 ng/g, while the third contained 1.5 ng/g NAB and 7.7 ng/g NNN. The 100-puff sets resulted in 336–515 mg liquid consumption, with no TSNAs being detected in the aerosol. The spiked sample contained 42.0–53.9 ng/g of each of the TSNAs. All TSNAs were detected in the aerosol with the measured levels being statistically similar to the expected amounts. A significant correlation between expected and measured levels of TSNAs in the aerosol was found (r = 0.83, p < 0.001. Conclusion: The findings of this study show that exposure of EC users to TSNAs can be accurately assessed based on the levels present in the liquid, without the need to analyze the aerosol.

  18. Vitamin B12 and folate levels in normal population of northern Pakistan

    International Nuclear Information System (INIS)

    Madood-ul-mannan; Anwar, M.; Saleem, M.; Waqar, A.; Ahmad, M.

    1990-01-01

    Diagnosis of vitamin B12 or folate deficiency can not be made unless reference ranges of these vitamins in a given population are known. These serum levels depend upon the dietary intake of these vitamins which in turn depends upon the availability of foods containing these vitamins and the methods of cooking/processing. The latter vary in different populations. Therefore serum level of these vitamins would vary in different populations. Serum levels of vitamin B12 and folate were estimated by radioimmunoassay technique in 30 normal subjects of different age groups. The levels of vitamin B12 were found to be 215.2 pg/ml and that of folate 3.9 ng/ml. These values are much lower than those described for European population. It is therefore concluded that the cut off point of the levels of these vitamins should be different than the European figures. (author)

  19. Valgus-varus motion of the knee in normal level walking and stair climbing.

    Science.gov (United States)

    Yu, B; Stuart, M J; Kienbacher, T; Growney, E S; An, K-N

    1997-07-01

    OBJECTIVE: The knee valgus-varus moment and the knee angles were compared between normal level walking and stair climbing. DESIGN: Ten healthy subjects were tested for ascent, descent, and level walking. BACKGROUND: An understanding of the normal valgus-varus motion of the knee during stair climbing is needed to apply biomechanical analysis of stair climbing as a evaluation tool for knee osteoarthritis patients. METHODS: A motion analysis system, three force plates, and a flight of stairs were used to collect kinematic and kinetic data. The knee angles and moments were calculated from the collected kinematic and kinetic data. RESULTS: The knee varus angle for the maximum knee valgus moments in stair climbing was significantly greater than that in level walking. The knee valgus moment was significantly correlated to ground reaction forces and knee valgus-varus angle during stair climbing and level walking. CONCLUSIONS: There is a coupling between the knee valgus-varus motion and flexion-extension motion. Ground reaction forces are the major contributors to the within-subject variation in the knee valgus-varus moment during stair climbing and level walking. The knee valgus-varus angle is a major contributor to the between-subject variation in the knee valgus moment during stair climbing and level walking.

  20. High performance liquid-level sensor based on mPOFBG for aircraft applications

    DEFF Research Database (Denmark)

    Marques, C. A. F.; Pospori, A.; Saez-Rodriguez, D.

    2015-01-01

    A high performance liquid-level sensor based on microstructured polymer optical fiber Bragg grating (mPOFBG) array sensors is reported in detail. The sensor sensitivity is found to be 98pm/cm of liquid, enhanced by more than a factor of 9 compared to a reported silica fiber-based sensor....

  1. Annual report on the effluent control of low level liquid water in Tokai Works. FY2004

    International Nuclear Information System (INIS)

    Takeishi, Minoru; Miyagawa, Naoto; Watanabe, Hitoshi

    2005-08-01

    This report was written about the effluent control of low level liquid waste in JNC Tokai Works Fiscal Year 2004, from 1st April 2004 to 31th March 2005. In this period, the quantities and concentrations of radioactivity in liquid waste from Tokai Works were under the discharge limits of 'Safety Regulations for the Tokai Reprocessing Plant' and regulations of government. (author)

  2. Vasopressin and oxytocin levels during normal pregnancy: effects of chronic dietary sodium restriction.

    Science.gov (United States)

    van der Post, J A; van Buul, B J; Hart, A A; van Heerikhuize, J J; Pesman, G; Legros, J J; Steegers, E A; Swaab, D F; Boer, K

    1997-03-01

    Neurohypophysial hormones are thought to be involved in alterations in fluid balance during pregnancy and delivery. In the course of normal pregnancy intravascular volume is increased whereas sodium restriction is thought to reduce plasma volume and cardiac output. In the present study, we measured the effect of long-term severe sodium restriction on vasopressin (AVP) and oxytocin (OT) levels during normal pregnancy and after delivery. Fifty-nine healthy nulliparous women were randomized either for a low sodium diet (20 mmol sodium daily) or for a normal diet from week 12 of pregnancy onwards. Circulating plasma levels and urinary excretion of AVP and OT, their neurophysins (Np-AVP and Np-OT) and AVP bound to platelets were determined at regular intervals during pregnancy and after delivery. After completion of the study, women on a sodium-restricted diet were compared with control women on a normal diet using repeated measurement ANOVA with adjustment for potentially confounding variables. After randomization, a reduction in urinary sodium excretion of, on average, 40-82% was found. In general, no effect of sodium restriction could be demonstrated on the various parameters (0.53 sodium restriction compared with non-smokers having a normal diet (P = 0.018). For all parameters, clear changes were found in the course of pregnancy and puerperium (P pregnancy. After birth, free plasma AVP, platelet-bound AVP, OT, osmolality, sodium and potassium increased, while Np-AVP and Np-OT decreased. Although elevated Np-AVP and Np-OT levels during pregnancy seem to indicate increased release of neurohypophysial hormones, pregnancy up to 36 weeks of gestation is accompanied by low circulating AVP and OT levels. Long-term severe sodium restriction diminishes urinary AVP excretion in (non-smoking) pregnant women, without changing circulating levels of AVP and OT, despite the known reduction in circulating volume. The reduced circulating (platelet-bound) AVP levels during pregnancy

  3. Solvency and Liquidity Level Trade-off: Does it Exist in Croatian Banking Sector?

    Directory of Open Access Journals (Sweden)

    Kundid Novokmet Ana

    2016-11-01

    Full Text Available We focus on 32 Croatian banks in the period 2002-2010 in order to investigate the solvency-liquidity nexus. Dynamic panel data analysis is applied on two basic models in which current liquidity ratio and equity to assets ratio are set as dependent variables, interchangeably, and other explanatory variables employed to capture the effect of bank size, profitability and asset quality as well as macroeconomic environment. We found two-way positive relationship between bank solvency and liquidity. However, bank size plays an important role in the capital and liquidity management, and trade-off between the solvency and liquidity level is found for the larger banks. Therefore, policymakers should take into consideration capital and liquidity interdependence, as well as the bank size effect when designing capital and liquidity requirements in order to downsize the regulatory burden for smaller banks, and increase them for larger banks. Namely, larger banks tend to minimize regulatory costs by avoiding simultaneous increase of liquidity and solvency. Small banks do exactly the opposite and stock both, capital and liquidity, what potentially makes their funds allocation sub-optimal, from their own as well as social point of view. Altogether, the paper contributes to scarce empirical evidence regarding bank solvency and liquidity interdependence, particularly when the post-transitional banking sectors are taken into consideration. It adds to knowledge on bank financial management in praxis, and bank managers and prudential authorities might find it relevant for their policies design and implementation.

  4. Derived release limits (DRL's) for airborne and liquid effluents from the Chalk River Nuclear Laboratories during normal operations

    International Nuclear Information System (INIS)

    Palmer, J.F.

    1981-02-01

    Derived release limits (DRL's), based on regulatory dose limits, have been calculated for routine discharges of radioactivity in airborne and liquid effluents from the Chalk River Nuclear Laboratories. Three types of sources of airborne effluents were considered: the NRX/NRU stack, the 61 m stack connected to the 99 Mo production facility, and a roof vent typical of those installed on several buildings on the site. Sources of liquid effluents to the Ottawa River were treated as a single source from the site as a whole. Various exposure pathways to workers on the site and to members of the public outside the site boundary were considered in the calculations. The DRL's represent upper limits for routine emissions of radioactivity from the Chalk River Nuclear Laboratories to the surrounding environment. Actual releases are regulated by Administrative Levels, set lower than the DRL's, and are confirmed by monitoring. (author)

  5. Low-level liquid waste decontamination by inorganic ion exchange

    International Nuclear Information System (INIS)

    Campbell, D.O.; Lee, D.D.; Dillow, T.A.

    1990-01-01

    Improved processes are being developed to treat contaminated liquid wastes that have been and continue to be generated at Oak Ridge National Laboratory. The most serious contaminants are 137 Cs and 90 Sr, and certain inorganic ion-exchange material have given promising results. Nickel and cobalt hexacyanoferrate (II) compounds are extremely selective for cesium removal, with distribution coefficients in excess of 10 6 even in the presence of high cesium and moderate potassium concentrations. Sodium titanate is selective for strontium removal from solutions with high alkali metal concentrations, especially at high pH. These separations are so efficient that one or two stages of simple, batch separation can yield large DFs (∼10 4 ) while still generating small volumes of solid waste

  6. Low-level liquid waste decontamination by organic ion exchange

    International Nuclear Information System (INIS)

    Lee, D.D.; Campbell, D.O.; Dillow, T.A.

    1990-01-01

    Improved processes are being developed to treat contaminated liquid wastes that have been and continue to be generated at Oak Ridge National Laboratory. Promising results have been obtained for cesium removal with a new resorcinol-based organic resin developed at the Savannah River Site. In tests of cesium removal, it was superior to other available resins, such as Duolite CS-100, with the distribution coefficient being limited primarily by competition from potassium and nearly independent of the sodium concentration. The optimum pH was approximately 12.5 in high NaNO 3 concentrations (>2 M). A fairly low flow velocity was required to yield sharp breakthrough of the loaded cesium. The resin was much less effective for strontium removal, which was limited by competition from sodium. If both cesium and strontium must be removed, another resin column or a mixed bed with a chelating resin should be used

  7. Liquid Chromatography–Mass Spectrometry Based Metabolomics Study of Cloned versus Normal Pigs Fed Either Restricted or Ad Libitum High-Energy Diets

    DEFF Research Database (Denmark)

    Christensen, Kirstine Lykke; Hedemann, Mette Skou; Jørgensen, Henry

    2012-01-01

    Genetically identical cloned pigs should in principle eliminate biological variation and provide more pronounced effects when subjected to, e.g., dietary interventions, but little is known about how phenotype and phenotypic variation is affected by cloning. Therefore, an investigation...... of the metabolome of cloned pigs compared to normal control pigs was performed to elucidate the variation and possible differences in the metabolic phenotypes during a dietary intervention. A total of 19 control pigs and 17 cloned pigs were given the same high-energy dense diet either ad libitum or in a restricted...... manner (60% of ad libitum) for 6 months, and plasma was subjected to liquid chromatography–mass spectrometry nontargeted metabolomics and biochemical analyses. Low systemic levels of IGF-1 could indicate altered growth conditions and energy metabolism in cloned pigs. In response to ad libitum feeding...

  8. Six-year experiences in the operation of a low level liquid waste treatment plant

    International Nuclear Information System (INIS)

    Wen, S.-J.; Hwang, S.-L.; Tsai, C.-M.

    1980-01-01

    The operation of a low level liquid waste treatment plant is described. The plant is designed for the disposal of liquid waste produced primarily by a 40 MW Taiwan Research Reactor as well as a fuel fabrication plant for the CANDU type reactor and a radioisotopes production laboratory. The monthly volume treated is about 600-2500 ton of low level liquid waste. The activity levels are in the range of 10 -5 -10 -3 μCi/cm 3 . The continuous treatment system of the low level liquid waste treatment plant and the treatment data collected since 1973 are discussed. The advantages and disadvantages of continuous and batch processes are compared. In the continuous process, the efficiency of sludge treatment, vermiculite ion exchange and the adsorption of peat are investigated for further improvement. (H.K.)

  9. Liver histology in hepatitis C virus positive patients with normal and elevated alanine amino transferase levels

    International Nuclear Information System (INIS)

    Bhatty, S.A.; Shaikh, N.A.; Akhter, S.S.

    2009-01-01

    To compare liver histology in HCV RNA positive patients with normal and elevated Alanine Aminotransferase Level (AST). This Cohort (prospective) study was conducted at Civil Hospital Karachi from Jan 2007 to July 2007. Forty patients with positive HCV RNA were included. Their liver function tests were followed for three months. Those having normal ALT on three occasions were taken as controls and those having elevated ALT were taken as cases. Liver biopsy was performed, Specimens were reviewed by single pathologist. Scheuer's scoring for grading of inflammation and staging of fibrosis of chronic hepatitis was used. Out of Forty patients having positive HCV RNA, 14 (35%) were male and 26 (65%) were female. Mean ALT in control group was 27.3 +- 6.1mu/l, mean ALT in cases was 91.7 +- 39.95 mu/l. Mean age in controls was 34.2 +- 10.75 years and in cases was 33.6 +- 9.40 years. On histopathology, the mean grade of inflammation in controls was 1.40 +- 0.681 while in cases was 1.20 +- 0.834, which was not statistically significantly different in the two groups (p= 0.411). Similarly mean staging of fibrosis in controls was 1.20 +- 0.768 and in cases was 1.35 +- 1.348 which was also not statistically different in the two groups (p=0.668). Stage 3 and 4 fibrosis was seen only in raised ALT group and not in the controls. Patients with persistently normal ALT and elevated ALT, although had similar grading of inflammation but the fibrosis score was more in elevated ALT group. None of the patients with normal ALT had normal histology, so decision for antiviral treatment should be individualized in this group also (JPMA 59:832; 2009). (author)

  10. Normal levels of total body sodium and chlorine by neutron activation analysis

    International Nuclear Information System (INIS)

    Kennedy, N.S.J.; Eastell, R.; Smith, M.A.; Tothill, P.

    1983-01-01

    In vivo neutron activation analysis was used to measure total body sodium and chlorine in 18 male and 18 female normal adults. Corrections for body size were developed. Normalisation factors were derived which enable the prediction of the normal levels of sodium and chlorine in a subject. The coefficient of variation of normalised sodium was 5.9% in men and 6.9% in women, and of normalised chlorine 9.3% in men and 5.5% in women. In the range examined (40-70 years) no significant age dependence was observed for either element. Total body sodium was correlated with total body chlorine and total body calcium. Sodium excess, defined as the amount of body sodium in excess of that associated with chlorine, also correlated well with total body calcium. In females there was a mean annual loss of sodium excess of 1.2% after the menopause, similar to the loss of calcium. (author)

  11. Oral triiodothyronine normalizes triiodothyronine levels after surgery for pediatric congenital heart disease*.

    Science.gov (United States)

    Marwali, Eva M; Boom, Cindy E; Sakidjan, Indriwanto; Santoso, Anwar; Fakhri, Dicky; Kartini, Ay; Kekalih, Aria; Schwartz, Steven M; Haas, Nikolaus A

    2013-09-01

    This study was conducted to determine if oral triiodothyronine supplementation could prevent the decrease of serum triiodothyronine levels that commonly occurs after cardiopulmonary bypass for pediatric congenital heart surgery. Secondary objectives included identifying any significant adverse effects of oral triiodothyronine supplementation, including any effects on the thyroid/pituitary axis. Randomized, placebo-controlled, doubleblind clinical trial Operating room and ICU. Infants and children younger than 2 years of age undergoing congenital heart surgery using cardiopulmonary bypass (n = 43). Subjects were assigned to placebo (n = 15, group A) or one of two treatment groups: a low-dose group (group B, n = 14, 0.5 mcg/kg triiodothyronine orally every 24 hr for 3 d) or a high-dose group (group C, n = 14, 0.5 mcg/kg triiodothyronine orally every 12 hr for 3 d). Thyroid hormone, including total and free triiodothyronine levels at predetermined time points, potential side effects indicating hyperthyroidism, indicators of the thyroid-pituitary axis, and clinical endpoints. Oral triiodothyronine supplementation twice-daily maintained serum triiodothyronine levels within normal limits in group C, whereas serum levels progressively declined in groups A and B. A statistically significant difference in triiodothyronine levels between the treatment groups occurred between 18 and 36 hours post cross-clamp release, with the largest difference in serum levels between group C and group A noted at 36 hours post cross-clamp release (total triiodothyronine, 0.71 ± 0.15 [0.34-1.08] ng/mL [p triiodothyronine, 2.56 ± 0.49 [1.33-3.79] pg/mL [p triiodothyronine supplementation at a dose of 0.5 mcg/kg every 12 hours for 3 days can maintain total and free triiodothyronine levels within normal limits after open-heart surgery using cardiopulmonary bypass for congenital heart disease.

  12. Development of a test system for high level liquid waste partitioning

    OpenAIRE

    Duan Wu H.; Chen Jing; Wang Jian C.; Wang Shu W.; Wang Xing H.

    2015-01-01

    The partitioning and transmutation strategy has increasingly attracted interest for the safe treatment and disposal of high level liquid waste, in which the partitioning of high level liquid waste is one of the critical technical issues. An improved total partitioning process, including a tri-alkylphosphine oxide process for the removal of actinides, a crown ether strontium extraction process for the removal of strontium, and a calixcrown ether cesium extra...

  13. HCV carriers with normal aminotransferase levels: “normal” does not always mean “healthy”

    Directory of Open Access Journals (Sweden)

    Claudio Puoti

    2013-04-01

    Full Text Available BACKGROUND Approximately 30% of patients with chronic HCV infection show persistently normal ALT levels (PNALT, and another 40% have minimally raised ALT values. Although formerly referred to as “healthy” or “asymptomatic” HCV carriers, it has now become clear that the majority of these patients have some degree of histological liver damage. Controversies still exist regarding the definition of “persistent” ALT normality, the virological and histological features of these subjects, and the natural history and optimal management of chronic hepatitis C (CHC with normal ALT. Most patients with normal ALT have histologically proven liver damage that may be significant (> F2 in up to 20% of patients, and might progress toward more severe degree of liver fibrosis. A significant proportion of patients (≥ 20% experiences periods of increased serum ALT (flare associated with disease progression. AIM OF THE STUDY The introduction of the new combination therapy of PEG-IFN plus ribavirin allowed response rates higher than 50%, with a favourable risk-benefit ratio also in patients with benign or slow progressive disease. Given the efficacy of the new treatments, which soon became the standard of care for CHC, it has been suggested that the issue of whether or not to treat subjects with PNALT should be re-evaluated. ALT levels may have less importance in deciding who should be treated. Many other factors might influence the decision to treat, such as the age of the patient, HCV genotype, liver histology, patient’s motivation, symptoms, extrahepatic manifestations, comorbid illness. The role of non-invasive tools for the assessment of liver fibrosis (transient hepatic elastography remains to be further validated.

  14. A radioimmunoassay for erythropoietin: serum levels in normal human subjects and patients with hemopoietic disorders

    International Nuclear Information System (INIS)

    Rege, A.B.; Brookins, J.; Fisher, J.W.

    1982-01-01

    An RIA for Ep has been developed that is highly sensitive and specific. A homogeneous Ep preparation was labeled with 125 I by the chloramine-T method to a specific activity of 90 to 136 micro Ci/microgram and immunoreactivity of 80%. Ep antiserum, which was produced to a human urinary Ep preparation (80 U/mg of protein), was adsorbed with normal human urinary and serum proteins without any loss in sensitivity of the RIA to increase the specificity of the assay. A good correlation was seen between the RIA and the exhypoxic polycythemic mouse assay (corr. coef. 0.967; slope 1.05 and y intercept 0.75). Ep titers in sera from 175 hematologically normal human subjects exhibited a normal frequency distribution and ranged between 5.8 and 36.6 mU/ml with a mean of 14.9 +/- 4.7 (S.D.) and median of 14.3 Serum Ep titers were markedly elevated in seven patients with aplastic anemia and one patient with pure red cell aplasia (1350 to 20,640 mU/ml) and were lower than normal in two patients with polycythemia vera (8.1 and 9.4 mU/ml). The serum Ep titers in a prenephrectomy patient with chronic glomerulonephritis (32.1 mU/ml) decreased to below normal levels (9.04 mU/ml) after nephrectomy. The cord serum erythropoietin titers in 10 IDM [90.82 +/- 134.1 (S.D.) mu/ml] returned to values within the normal range (13.86 +/- 5.55) on day 3 after birth, suggesting the utility of the RIA in elucidating the role of hypoxia and/or insulin in increased erythropoiesis in IDM. The serum Ep titers in patients with anemias and polycythemias were compared to those of normal human subjects and agreed well with pathophysiologic mechanisms of these hemopoietic disorders, confirming the validity of the RIA

  15. A radioimmunoassay for erythropoietin: serum levels in normal human subjects and patients with hemopoietic disorders

    International Nuclear Information System (INIS)

    Rege, A.B.; Brookins, J.; Fisher, J.W.

    1982-01-01

    An RIA for Ep has been developed that is highly sensitive and specific. A homogeneous Ep preparation was labeled with 125 I by the chloramine-T method to a specific activity of 90 to 136 μCi/μg and immunoreactivity of 80%. Ep antiserum, which was produced to a human urinary Ep preparation (80 U/mg of protein), was adsorbed with normal human urinary and serum proteins without any loss in sensitivity of the RIA to increase the specificity of the assay. A good correlation was seen between the RIA and the exhypoxic polycythemic mouse assay (corr. coef. 0.967; slope 1.05 and ''y'' intercept 0.75). Ep titers in sera from 175 hematologically normal human subjects exhibited a normal frequency distribution and ranged between 5.8 and 36.6 mU/ml with a mean of 14.9 +/- 4.7 (S.D.) and median of 14.3. Serum Ep titers were markedly elevated in seven patients with aplastic anemia and one patient with pure red cell aplasia (1350 to 20,640 mU/ml) and were lower than normal in two patients with polycythemia vera (8.1 and 9.4 mU/ml). The serum Ep titers in a prenephrectomy patient with chronic glomerulonephritis (31.1 mU/ml) decreased to below normal levels (9.04 mU/ml) after nephrectomy. The cord serum erythropoietin titers in 10 IDM [90.82 +/- 134.1 (S.D.) mu/ml] returned to values within the normal range (13.86 +/- 5.55) on day 3 after birth, suggesting the utility of the RIA in elucidating the role of hypoxia and/or insulin in increased erythropoiesis in IDM. The serum Ep titers in patients with anemias and polycythemias were compared to those of normal human subjects and agreed well with pathophysiologic mechanisms of these hemopoietic disorders, confirming the validity of the RIA

  16. Low-level flow counting of liquid chromatography column eluates

    International Nuclear Information System (INIS)

    Harding, N.G.L.; Farid, Y.; Stewart, M.J.

    1982-01-01

    The principal parameters which determine the operation of a high-resolution, high-sensitivity radioactive flow monitor are described: a) Sample preparation to ensure adequate recovery of radiolabelled sample, metabolites and internal standard. b) The instrument background count rate, when no sample or radiolabel is present in the flow cell, is a function of shielding and a reduction in noise obtained with a coincidence time below one microsecond. c) The minimum detectable amount of label depends upon the machine background, HPLC eluent and scintillator flow, whether or not packed flow cells are used, flow cell geometry, and the scintillator used. d) Three types of flow cell have been designed to cover the majority of HPLC and isotope applications. e) The performance of solid and liquid scintillators. It is shown that an instrument has been designed taking account of these parameters. The resulting design satisfies present high sensitivity counting requirements and maintains the resolution of current HPLC procedures when detection is by simultaneous flow radioassay and by optical methods. (orig.)

  17. Low-level liquid waste decontamination by ion exchange

    International Nuclear Information System (INIS)

    Campbell, D.O.; Lee, D.D.; Dillow, T.A.

    1991-12-01

    Improved processes are being developed to treat contaminated liquid wastes that have been and continue to be generated at Oak Ridge National Laboratory. Both inorganic and organic ion-exchange methods have given promising results. Nickel and cobalt hexacyanoferrate(2) compounds are extremely selective for cesium removal, with distribution coefficients in excess of 10 6 and remarkable insensitivity to competition from sodium and potassium. They tend to lose effectiveness at pH > ∼11, but some formulations are useful for limited periods of time up to pH ∼13. Sodium titanate is selective for strontium removal at high pH. The separations are so efficient that simple batch processes can yield large decontamination factors while generating small volumes of solid waste. A resorcinol-based resin developed at the Savannah River Site gave superior cesium removal, compared with other organic ion exchangers; the distribution coefficient was limited primarily by competition from potassium and was nearly independent of sodium. The optimum pH was ∼12.5. It was much less effective for strontium removal, which was limited by competition from sodium. 8 refs., 6 figs., 9 tabs

  18. A Float Type Liquid Level Measuring System Using a Modified Inductive Transducer

    Directory of Open Access Journals (Sweden)

    Samik MARICK

    2014-11-01

    Full Text Available Float type liquid level sensor is generally used as a very simple technique for local level indication and level switching. In the present paper a technique has been proposed to transmit the measured liquid level signal of a float type sensor at remote terminal using a modified differential inductance type electromechanical transducer. The theoretical characteristic equation of this transducer has been derived. A prototype unit of the transducer has been developed and fabricated and its performance characteristic has been experimentally determined. The experimental results are reported in the paper. From experimental data, a very good linear characteristic of the proposed level transducer has been observed.

  19. Risk comparison of different treatment and disposal strategies of high level liquid radioactive waste

    International Nuclear Information System (INIS)

    Fang Dong

    1997-01-01

    The risk of different treatment and disposal strategies of high level liquid radioactive waste from spent fuel reprocessing is estimated and compared. The conclusions obtained are that risk difference from these strategies is very small and high level liquid waste can be reduced to middle and low level waste, if the decontamination factor for 99 Tc is large enough, which is the largest risk contributor in the high level radioactive waste from spent fuel reprocessing. It is also shown that the risk of high level radioactive waste could be reduced by the technical strategy of combining partitioning and transmutation

  20. Total levels of hippocampal histone acetylation predict normal variability in mouse behavior.

    Directory of Open Access Journals (Sweden)

    Addie May I Nesbitt

    Full Text Available Genetic, pharmacological, and environmental interventions that alter total levels of histone acetylation in specific brain regions can modulate behaviors and treatment responses. Efforts have been made to identify specific genes that are affected by alterations in total histone acetylation and to propose that such gene specific modulation could explain the effects of total histone acetylation levels on behavior - the implication being that under naturalistic conditions variability in histone acetylation occurs primarily around the promoters of specific genes.Here we challenge this hypothesis by demonstrating with a novel flow cytometry based technique that normal variability in open field exploration, a hippocampus-related behavior, was associated with total levels of histone acetylation in the hippocampus but not in other brain regions.Results suggest that modulation of total levels of histone acetylation may play a role in regulating biological processes. We speculate in the discussion that endogenous regulation of total levels of histone acetylation may be a mechanism through which organisms regulate cellular plasticity. Flow cytometry provides a useful approach to measure total levels of histone acetylation at the single cell level. Relating such information to behavioral measures and treatment responses could inform drug delivery strategies to target histone deacetylase inhibitors and other chromatin modulators to places where they may be of benefit while avoiding areas where correction is not needed and could be harmful.

  1. Separation of aromatic precipitates from simulated high level radioactive waste by hydrolysis, evaporation and liquid-liquid extraction

    International Nuclear Information System (INIS)

    Young, S.R.; Shah, H.B.; Carter, J.T.

    1991-01-01

    The Defense Waste Processing Facility (DWPF) at the SRS will be the United States' first facility to process High Level radioactive Waste (HLW) into a borosilicate glass matrix. The removal of aromatic precipitates by hydrolysis, evaporation and liquid-liquid extraction will be a key step in the processing of the HLW. This step, titled the Precipitate Hydrolysis Process, has been demonstrated by the Savannah River Laboratory with the Precipitate Hydrolysis Experimental Facility (PHEF). The mission of the PHEF is to demonstrate processing of simulated high level radioactive waste which contains tetraphenylborate precipitates and nitrite. Reduction of nitrite by hydroxylamine nitrate and hydrolysis of the tetraphenylborate by formic acid is discussed. Gaseous production, which is primarily benzene, nitrous oxide and carbon dioxide, has been quantified. Production of high-boiling organic compounds and the accumulation of these organic compounds within the process are addressed

  2. Renal failure in a patient with postpolio syndrome and a normal creatinine level.

    Science.gov (United States)

    Leming, Melissa K; Breyer, Michael J

    2012-01-01

    Patients with renal failure who are taking trimethoprim have an increased risk of developing hyperkalemia, which can cause muscle weakness. In patients with postpolio syndrome, a normal creatinine level could be abnormally high, renal failure is possible because of lack of creatinine production, and the muscle weakness from resultant hyperkalemia could be more severe because of their underlying condition. This abnormally high creatinine level has been termed from this point relative renal failure. The objective of the study was to review a case in which relative renal failure and hyperkalemia caused muscle weakness that manifested as shortness of breath and confusion with electrocardiographic changes. A dehydrated patient with relative renal failure and postpolio syndrome had taken trimethoprim-sulfamethoxazole that caused symptomatic hyperkalemia. The patient presented with muscle weakness, shortness of breath, and confusion, with her postpolio syndrome compounding the situation and likely making the muscle weakness more severe. A patient on trimethoprim with renal failure is at an increased risk of developing hyperkalemia. Patients with postpolio syndrome could have severe muscle weakness from the hyperkalemia and could have renal failure even with a normal creatinine level. This case report will remind treating physicians to evaluate such patients for hyperkalemia if they present with muscle weakness, especially if the patient has renal failure and is on trimethoprim. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Measurements of 222Rn and 226Ra Levels in environmental samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Moustafa, A.S.

    2004-01-01

    The advantageous of liquid scintillation counting technique for 6 Ra determination compared with other methods are the high counting efficiency and the easier sample preparation, with no need for sample pre-concentration. In this work, liquid scintillation counting system was used to measure 222 Rn and 226 Ra levels in environmental samples. The liquid scintillation cocktail was prepared in the laboratory and was found efficient for measuring 222 Rn. Soil, sediment and TENORM samples were dried, grind, sieved and added to hydrochloric acid, in a standard scintillation vial, preloaded with the liquid scintillation cocktail. By measuring 222 Rn levels in the prepared vials, at different intervals of time after preparation, 222 Rn and 226 Ra levels were determined

  4. Numerical simulation on stir system of jet ballast in high level liquid waste storage tank

    International Nuclear Information System (INIS)

    Lu Yingchun

    2012-01-01

    The stir system of jet ballast in high level liquid waste storage tank was simulation object. Gas, liquid and solid were air, sodium nitrate liquor and titanium whitening, respectively. The mathematic model based on three-fluid model and the kinetic theory of particles was established for the stir system of jet ballast in high level liquid waste storage tank. The CFD commercial software was used for solving this model. The detail flow parameters as three phase velocity, pressure and phase loadings were gained. The calculated results agree with the experimental results, so they can well define the flow behavior in the tank. And this offers a basic method for the scale-up and optimization design of the stir system of jet ballast in high level liquid waste storage tank. (author)

  5. Normal fasting plasma glucose levels and type 2 diabetes in young men.

    Science.gov (United States)

    Tirosh, Amir; Shai, Iris; Tekes-Manova, Dorit; Israeli, Eran; Pereg, David; Shochat, Tzippora; Kochba, Ilan; Rudich, Assaf

    2005-10-06

    The normal fasting plasma glucose level was recently defined as less than 100 mg per deciliter (5.55 mmol per liter). Whether higher fasting plasma glucose levels within this range independently predict type 2 diabetes in young adults is unclear. We obtained blood measurements, data from physical examinations, and medical and lifestyle information from men in the Israel Defense Forces who were 26 to 45 years of age. A total of 208 incident cases of type 2 diabetes occurred during 74,309 person-years of follow-up (from 1992 through 2004) among 13,163 subjects who had baseline fasting plasma glucose levels of less than 100 mg per deciliter. A multivariate model, adjusted for age, family history of diabetes, body-mass index, physical-activity level, smoking status, and serum triglyceride levels, revealed a progressively increased risk of type 2 diabetes in men with fasting plasma glucose levels of 87 mg per deciliter (4.83 mmol per liter) or more, as compared with those whose levels were in the bottom quintile (less than 81 mg per deciliter [4.5 mmol per liter], P for trend <0.001). In multivariate models, men with serum triglyceride levels of 150 mg per deciliter (1.69 mmol per liter) or more, combined with fasting plasma glucose levels of 91 to 99 mg per deciliter (5.05 to 5.50 mmol per liter), had a hazard ratio of 8.23 (95 percent confidence interval, 3.6 to 19.0) for diabetes, as compared with men with a combined triglyceride level of less than 150 mg per deciliter and fasting glucose levels of less than 86 mg per deciliter (4.77 mmol per liter). The joint effect of a body-mass index (the weight in kilograms divided by the square of the height in meters) of 30 or more and a fasting plasma glucose level of 91 to 99 mg per deciliter resulted in a hazard ratio of 8.29 (95 percent confidence interval, 3.8 to 17.8), as compared with a body-mass index of less than 25 and a fasting plasma glucose level of less than 86 mg per deciliter. Higher fasting plasma glucose

  6. Optical Mass Gauging System for Measuring Liquid Levels in a Reduced Gravity Environment

    Science.gov (United States)

    Sullenberger, Ryan M.; Munoz, Wesley M.; Lyon, Matt P.; Vogel, Kenny; Yalin, Azer P.; Korman, Valentin; Polzin, Kurt A.

    2010-01-01

    A compact and rugged fiber-coupled liquid volume sensor designed for flight on a sounding rocket platform is presented. The sensor consists of a Mach-Zehnder interferometer capable of measuring the amount of liquid contained in a tank under any gravitational conditions, including a microgravity environment, by detecting small changes in the index of refraction of the gas contained within a sensing region. By monitoring changes in the interference fringe pattern as the system undergoes a small compression provided by a piston, the ullage volume of a tank can be directly measured allowing for a determination of the liquid volume. To demonstrate the technique, data are acquired using two tanks containing different volumes of liquid, which are representative of the levels of liquid in a tank at different time periods during a mission. The two tanks are independently exposed to the measurement apparatus, allowing for a determination of the liquid level in each. In a controlled, laboratory test of the unit, the system demonstrated a capability of measuring a liquid level in an individual tank of 10.53 mL with a 2% error. The overall random uncertainty for the flight system is higher than that one test, at +/- 1.5 mL.

  7. Serum erythropoietin level in anemic and non-anemic nephrotic children with normal kidney functions

    International Nuclear Information System (INIS)

    Moustafa, A.M.E.; Moawad, A.T.; Gad, A.A.; Ahmed, S.M.

    2005-01-01

    Nephrotic syndrome (NS) is associated with a significant alteration in protein metabolism. While lowering the concentration of certain proteins, the disease often raises the level of certain other proteins. The current study aimed to investigate the serum erythropoietin (EPO) levels in children with NS either anemic or non-anemic and to compare them to children with iron deficiency anemia (IDA) and healthy controls with normal hemoglobin level (NHB). Sixteen nephrotic children with anemia (NS-A) and 15 nephrotic children with normal hemoglobin level (NS-NHB) were examined and compared with 10 children with iron deficiency anemia (IDA) and 10 healthy controls (NHB). Circulating serum EPO levels, blood indices and iron status were measured in nephrotic patients with anemia (NS-A) and compared to those nephrotic patients with normal HE (NS-NHB). Most NS-A children were steroid resistant. The NS-A children showed greater EPO levels than those without anemia (21.01 ±4.02 mlU/ml versus 9.18 ± 0.79 mlU/ml; P < 0.001) but their response to treatment of anemia was inappropriately low when compared to IDA (EPO 96.9 ±4.9 mlU/ml) despite similar HB concentration. A significant positive correlation was observed between serum EPO and serum albumin in NS-A (r = 0.84, P < 0.001) and in NS-NHB group (r = 0.89, P < 0.001). Moreover, a significant positive correlation was observed between serum EPO and HB in the nephrotic groups indicating a blunted EPO response to anemia in NS-A (r 0.63, P < 0.05) and in NS-NHB group (r = 0.80, P < 0.001). In conclusion, anemia is a common feature of NS and is present even before the worsening of kidney function. Depletion of the iron stores due to loss of iron and transferrin in urine due to massive proteinurea may contribute to the development of anemia, but it was found that iron replacement was ineffective alone

  8. Influence of insulin on beta-endorphin plasma levels in obese and normal weight subjects.

    Science.gov (United States)

    Brunani, A; Pincelli, A I; Pasqualinotto, L; Tibaldi, A; Baldi, G; Scacchi, M; Fatti, L M; Cavagnini, F

    1996-08-01

    To establish the possible role of hyperinsulinemia in the elevation of plasma beta-endorphin (beta-EP) levels observed in obese patients after an oral glucose load. Oral glucose tolerance test (OGTT) and euglycemic-hyperinsulinemic clamp. Two groups of six (age: 22-39 y, BMI: 30-48 kg/m2) and eight obese men (age: 18-37 y, BMI: 35-45 kg/m2), respectively, and five normal weight healthy men (age: 22-30 y, BMI 22-23 kg/m2). Glucose, insulin and beta-EP levels at baseline and every 30 min until 180 min during the OGTT; glucose, insulin, C-peptide and beta-EP concentrations at baseline and in steady state condition (i.e. during the last 30 min of insulin infusion) in the euglycemic-hyperinsulinemic clamp studies. In the six obese patients undergoing the OGTT a significant elevation of beta-EP plasma levels was observed between 60 and 90 min after glucose ingestion. In the clamp studies no significant differences in beta-EP plasma levels, blood glucose and serum insulin were observed between obese and normal weight subjects both at baseline and at steady state. A markedly diminished insulin sensitivity along with a lower inhibition of C-peptide during insulin infusion was observed in obese patients compared to control subjects. A rise in serum insulin levels unaccompanied by a concomitant increase in blood glucose concentration is unable to elicit a beta-EP response in obese patients.

  9. Low level radioactive liquid waste treatment at ORNL

    International Nuclear Information System (INIS)

    Robinson, R.A.; Lasher, L.C.

    1977-01-01

    A new Process Waste Treatment Plant has been constructed at ORNL. The wastes are processed through a precipitation-clarification step and then through an ion exchange step to remove the low-level activity in the waste before discharge into White Oak Creek

  10. Higher levels of albuminuria within the normal range predict incident hypertension.

    Science.gov (United States)

    Forman, John P; Fisher, Naomi D L; Schopick, Emily L; Curhan, Gary C

    2008-10-01

    Higher levels of albumin excretion within the normal range are associated with cardiovascular disease in high-risk individuals. Whether incremental increases in urinary albumin excretion, even within the normal range, are associated with the development of hypertension in low-risk individuals is unknown. This study included 1065 postmenopausal women from the first Nurses' Health Study and 1114 premenopausal women from the second Nurses' Health Study who had an albumin/creatinine ratio who did not have diabetes or hypertension. Among the older women, 271 incident cases of hypertension occurred during 4 yr of follow-up, and among the younger women, 296 incident cases of hypertension occurred during 8 yr of follow-up. Cox proportional hazards regression was used to examine prospectively the association between the albumin/creatinine ratio and incident hypertension after adjustment for age, body mass index, estimated GFR, baseline BP, physical activity, smoking, and family history of hypertension. Participants who had an albumin/creatinine ratio in the highest quartile (4.34 to 24.17 mg/g for older women and 3.68 to 23.84 mg/g for younger women) were more likely to develop hypertension than those who had an albumin/creatinine ratio in the lowest quartile (hazard ratio 1.76 [95% confidence interval 1.21 to 2.56] and hazard ratio 1.35 [95% confidence interval 0.97 to 1.91] for older and younger women, respectively). Higher albumin/creatinine ratios, even within the normal range, are independently associated with increased risk for development of hypertension among women without diabetes. The definition of normal albumin excretion should be reevaluated.

  11. Sleep habits, food intake, and physical activity levels in normal and overweight and obese Malaysian children.

    Science.gov (United States)

    Firouzi, Somayyeh; Poh, Bee Koon; Ismail, Mohd Noor; Sadeghilar, Aidin

    2014-01-01

    This study aimed to determine the association between sleep habits (including bedtime, wake up time, sleep duration, and sleep disorder score) and physical characteristics, physical activity level, and food pattern in overweight and obese versus normal weight children. Case control study. 164 Malaysian boys and girls aged 6-€“12 years. Anthropometric measurements included weight, height, waist circumference, and body fat percentage. Subjects divided into normal weight (n = 82) and overweight/obese (n = 82) group based on World Health Organization 2007 BMI-for-age criteria and were matched one by one based on ethnicity, gender, and age plus minus one year. Questionnaires related to sleep habits, physical activity, and food frequency were proxy-reported by parents. Sleep disorder score was measured by Children Sleep Habit Questionnaire. Sleep disorder score and carbohydrate intake (%) to total energy intake were significantly higher in overweight/obese group (p < 0.01 and p < 0.05, respectively). After adjusting for age and gender, sleep disorder score was correlated with BMI (r = 0.275, p < 0.001), weight (r = 0.253, p < 0.001), and WC (r = 0.293, p < 0.001). Based on adjusted odd ratio, children with shortest sleep duration were found to have 4.5 times higher odds of being overweight/obese (odd ratio: 4.536, 95% CI: 1.912-€“8.898) compared to children with normal sleep duration. The odds of being overweight/obese in children with sleep disorder score higher than 48 were 2.17 times more than children with sleep disorder score less than 48. Children who sleep lees than normal amount, had poor sleep quality, and consumed more carbohydrates were at higher risk of overweight/obesity. © 2014 Asian Oceanian Association for the Study of Obesity . Published by Elsevier Ltd. All rights reserved.

  12. Equine alpha-fetoprotein levels in Lipizzaner mares with normal pregnancies and with pregnancy loss.

    Science.gov (United States)

    Vincze, Boglárka; Gáspárdy, András; Kulcsár, Margit; Baska, Ferenc; Bálint, Ádám; Hegedűs, György Tamás; Szenci, Ottó

    2015-12-01

    Alpha-fetoprotein has proved to be a good indicator of fetal well-being in human medicine for decades. Although this molecule is present in most of the mammalian species including horses, reference values in healthy and high-risk pregnant mares have not yet been published. The aim of the present study was to determine whether equine alpha-fetoprotein (eqAFP) is a good indicator of complicated pregnancies in Lipizzaner mares. A total of 111 serum samples from 30 mares have been analyzed for eqAFP levels throughout gestation (Days 60-325). After the pregnancy was confirmed, 23 mares had normal pregnancies with viable foals, six had late embryonic loss, and one of the mares aborted in the ninth gestational month. Equine alpha-fetoprotein concentrations significantly differed in the normal group (72.93 ± 49.25 pg/mL; mean ± standard deviation) and in the complicated pregnancy loss group (152 ± 36.48 pg/mL; mean ± standard deviation). The mares' age, gestational age, and the conception rate significantly affected the alpha-fetoprotein concentrations in the normal group. Furthermore, notable individual differences occurred in eqAFP concentrations between mares. Equine alpha-fetoprotein seems to be an important indicator of fetal well-being in horses, but there are still some unanswered questions (levels in foals of different age, ponies, and draft horses) regarding this serum protein. Large-scale studies are needed to assess the specificity, sensitivity, and reliability of this test as a possible future diagnostic tool for fetal well-being in horses. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Effect of AGE and Sex on thyroid hormone levels in normal egyptian individuals using RIA technique

    International Nuclear Information System (INIS)

    Abdel-Aziz, S.M.; El-Seify, S.; Megahed, Y.M.; El-Arab, A.

    1993-01-01

    This work aims to estimate total serum levels of thyroid hormones, namely triiodothyronine (T 3 ) and thyroxine (T 4 ) as well as the pituitary thyrotropin (TSH) in different categories of normal egyptian individuals classified according to age and sex. Radioimmunoassay (RIA) and immunoradiometritassay (IRMA) techniques were used. Results of this study indicate that T 3 and T 4 concentrations decreased significantly with advancing age. This decrement was statistically significant in both sexes and could be attributed to the decline in TBG concentration in the elderly. TSH level was not influenced by sex, however, a slight decrease was observed in the elderly perhaps due to decreased TSH receptors and or cyclic AMP activity. 3 figs., 2 tabs

  14. Reduced interhemispheric interaction in non-autistic individuals with normal but high levels of autism traits.

    Science.gov (United States)

    O'Keefe, Natalie; Lindell, Annukka K

    2013-11-01

    People with autism spectrum disorder (ASD) show superior performance for tasks requiring detail-focused processing. Atypical neural connectivity and reduced interhemispheric communication are posited to underlie this cognitive advantage. Given recent conceptualization of autism as a continuum, we sought to investigate whether people with normal but high levels of autism like traits (AQ) also exhibit reduced hemispheric interaction. Sixty right-handed participants completed the AQ questionnaire (Baron-Cohen, Wheelwright, Skinner, Martin, & Clubley, 2001) and a lateralised letter matching task that assessed unilateral and bilateral performance in response to simple (physical) and complex (identity) matches. Whereas people with low self-rated AQ scores showed a bilateral advantage for the more complex task, indicating normal interhemispheric interaction, people in the high AQ group failed to show a bilateral gain for the computationally demanding stimuli. This finding of disrupted interhemispheric interaction converges with a dimensional conceptualisation of ASD, suggesting that the structural anomalies of ASD extend to non-autistic individuals with high levels of autism traits. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Overweight and obese children have lower cortisol levels than normal weight children.

    Science.gov (United States)

    Kjölhede, E Allansson; Gustafsson, P E; Gustafsson, P A; Nelson, N

    2014-03-01

    The stress hormone cortisol is vital to survival, and a disturbed circadian rhythm can be deleterious to health. However, little is known about cortisol levels in healthy children. The aim of this study was to examine cortisol levels in relation to body mass index (BMI), age and sex. Salivary samples were collected in early morning, late morning and evening, on four consecutive days, from 342 children aged 6-12 years using Salivette(®) tubes. Samples were analysed using a commercial enzyme immunoassay (EIA). School nurses measured the children's height and weight, and these measurements were used to calculate their BMI. The children displayed a circadian rhythm in cortisol secretion, with morning zeniths and evening nadirs. Average cortisol levels in early morning, late morning and evening were significantly lower in overweight and obese children than in their normal weight counterparts. Cortisol levels did not vary significantly with age or sex. Our findings may suggest cortisol suppression in overweight and obese children. We found no evidence that sex or age influences cortisol levels. These findings highlight the need for further research on the relationship between stress and obesity in children. ©2013 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  16. Normal blood magnesium levels in volunteers of Rawalpindi by atomic absorption absorption technique

    International Nuclear Information System (INIS)

    Ahmed, I.; Rehman, S.; Yawar, W.; Rusheed, A.; Ahraf, M.; Syed, N.H.

    1999-01-01

    Magnesium levels in whole blood samples of 67 healthy volunteers (mean 6.46 -+ 0.221; range 1.345 - 13.163 mg/dL) of Rawalpindi district have been determined by flame atomic absorption spectrophotometric method. Magnesium levels of 41 male and 26 female subjects including doctors, nurses, patients attendees, medical students, sweepers and peons of Rawalpindi Medical College and Rawalpindi General Hospital revealed the normal mean blood levels of 6.088 - + 0.258 mg/dL (range 1.345 - 10.679 mg/dL)and 7.060 -+ 0.375 mg/dL (range 4.495 - 13.163 mg/dL),P<0.05 respectively. Only 10 male volunteers were smokers exhibiting 6.768 -+ 0.558 mg/dL (range 4.466 -10.679 mg/dL). Significant relationship was found in magnesium levels between males and females of poor socio-economic group (P<0.05). No relationship occurred between male smokers and non-smokers and magnesium levels in the age groups of males or females or both, when data was compared by 't' test. (author)

  17. Effects of delivery on maternal & neonatal irisin levels in normal and preeclamptic pregnant women.

    Science.gov (United States)

    Foda, Ashraf A; Foda, Engy A

    2017-10-01

    The aim of this work was to measure the irisin levels in maternal and umbilical cord serums at cesarean section and vaginal delivery. This is a case-control study conducted at the Obstetric Department of the Mansoura University Hospital, Mansoura University, Egypt. The 150 nulliparous cases were divided into three groups. Serum irisin concentrations were assayed by enzyme-linked immunosorbent assay (ELISA) method. Unpaired t-test and correlation were done by using the Statistical Package for Social Scientists (SPSS). The maternal irisin levels in cases with mild preeclampsia were found to be significantly lower than that of the normal cases. In cases with mild preeclampsia, the maternal irisin levels early in labor for vaginal deliveries were significantly higher than that during cesarean section. The maternal irisin levels after vaginal deliveries were significantly higher than the levels early in labor. The maternal serum irisin was a significantly correlated with the duration of the first stage. The umbilical cord serum irisin levels were significantly correlated with the neonatal weight and with the duration of the first stage of labor. Labor is a strong stimulus to the release of irisin into the maternal and fetal circulations. Neonatal serum irisin levels are positively correlated with the birth weight and with the duration of the first stage. The neonatal birth weight and the duration of the first stage of labor are positively correlated with the umbilical cord serum irisin levels. Copyright © 2017 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.

  18. Assessment of serum HE4 levels throughout the normal menstrual cycle.

    Science.gov (United States)

    Moore, Richard G; Plante, Beth; Hartnett, Erin; Mitchel, Jessica; Raker, Christine A; Vitek, Wendy; Eklund, Elizabeth; Lambert-Messerlian, Geralyn

    2017-07-01

    Human epididymis protein 4 is a serum biomarker to aid in differentiating benign and malignant disease in women with a pelvic mass. Interpretation of human epididymis protein 4 results relies on robust normative data. The purpose of this study was to evaluate whether human epididymis protein 4 levels are variable in women during the normal menstrual cycle. Healthy women, 18-45 years old, with regular menstrual cycles were recruited from community gynecologic practices in Rhode Island. Women consented to enroll and to participate by the donation of blood and urine samples at 5 specific times over the course of each cycle. Levels of reproductive hormones and human epididymis protein 4 were determined. Data were analyzed with the use of linear regression after log transformation. Among 74 enrolled cycles, 53 women had confirmed ovulation during the menstrual cycle and completed all 5 sample collections. Levels of estradiol, progesterone, and luteinizing hormone displayed the expected menstrual cycle patterns. Levels of human epididymis protein 4 in serum were relatively stable across the menstrual cycle, except for a small ovulatory (median, 37.0 pM) increase. Levels of human epididymis protein 4 in urine, after correction for creatinine, displayed the same pattern of secretion observed in serum. Serum human epididymis protein 4 levels are relatively stable across the menstrual cycle of reproductive-aged women and can be determined on any day to evaluate risk of ovarian malignancy. A slight increase is expected at ovulation; but even with this higher human epididymis protein 4 level, results are well within the healthy reference range for women (<120 pM). Levels of human epididymis protein 4 in urine warrant further investigation for use in clinical practice as a simple and convenient sample. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Programmable System-on-Chip (PSoC) Embedded Readout Designs for Liquid Helium Level Sensors.

    Science.gov (United States)

    Parasakthi, C; Gireesan, K; Usha Rani, R; Sheela, O K; Janawadkar, M P

    2014-08-01

    This article reports the development of programmable system-on-chip (PSoC)-based embedded readout designs for liquid helium level sensors using resistive liquid vapor discriminators. The system has been built for the measurement of liquid helium level in a concave-bottomed, helmet-shaped, fiber-reinforced plastic cryostat for magnetoencephalography. This design incorporates three carbon resistors as cost-effective sensors, which are mounted at desired heights inside the cryostat and were used to infer the liquid helium level by measuring their temperature-dependent resistance. Localized electrical heating of the carbon resistors was used to discriminate whether the resistor is immersed in liquid helium or its vapor by exploiting the difference in the heat transfer rates in the two environments. This report describes a single PSoC chip for the design and development of a constant current source to drive the three carbon resistors, a multiplexer to route the sensor outputs to the analog-to-digital converter (ADC), a buffer to avoid loading of the sensors, an ADC for digitizing the data, and a display using liquid crystal display cum light-emitting diode modules. The level sensor readout designed with a single PSoC chip enables cost-effective and reliable measurement system design. © 2014 Society for Laboratory Automation and Screening.

  20. Off-line separation and determination of rare earth elements associated with chloroplast pigments of hyperaccumulator Dicranopteris dichotoma by normal-phase liquid chromatography and ICP-MS.

    Science.gov (United States)

    Wei, Z G; Hong, F S; Yin, M; Li, H X; Hu, F; Zhao, G W; Wong, J W C

    2004-10-01

    An off-line normal-phase liquid chromatography-ICP-MS method has been used for separation and determination of the rare earth elements (REE) associated with chloroplast pigments of Dicranopteris dichotoma. The stability of REE-bound pigments was tested, and almost no destruction of REE-bound pigments occurred during the so-called normal-phase liquid chromatography. The accumulated free REE ions on the microcrystalline cellulose column were cleaned by elution with 5 mmol L(-1) 2-ethylhexyl hydrogen 2-ethylhexylphosphonate (P507), to avoid exchange of these free ions with metals from the pigments. When these precautions were taken, the method was applied to the study of REE-bound pigments in D. dichotoma. ICP-MS results showed REE were present in chlorophylls and lutein, although REE concentrations in carotene and pheophytin were both below procedural blank levels. By careful analysis of the eluate fractions containing chlorophyll a it was found that REE-bound chlorophyll a in D. dichotoma was slightly enriched in the fractions with relatively short retention time. Results indicated that the retention time of REE-bound chlorophyll a might be slightly less than that of magnesium chlorophyll a, and REE-bound chlorophylls might be of relatively low polarity in comparison with magnesium bound chlorophylls. This phenomenon could be explained by the special double-decker sandwich-structure of REE-bound chlorophylls, as was reported by us and other authors. On the basis of these results we preferred to consider that REE can replace magnesium in chlorophyll a of D. dichotoma, and that the role of REE-bound chlorophylls in photosynthesis cannot be neglected. These data might be useful for understanding of both the properties of REE-bound pigments and the effect of REE on plant photosynthesis.

  1. Design and operation of off-gas cleaning systems at high level liquid waste conditioning facilities

    International Nuclear Information System (INIS)

    1988-01-01

    The immobilization of high level liquid wastes from the reprocessing of irradiated nuclear fuels is of great interest and serious efforts are being undertaken to find a satisfactory technical solution. Volatilization of fission product elements during immobilization poses the potential for the release of radioactive substances to the environment and necessitates effective off-gas cleaning systems. This report describes typical off-gas cleaning systems used in the most advanced high level liquid waste immobilization plants and considers most of the equipment and components which can be used for the efficient retention of the aerosols and volatile contaminants. In the case of a nuclear facility consisting of several different facilities, release limits are generally prescribed for the nuclear facility as a whole. Since high level liquid waste conditioning (calcination, vitrification, etc.) facilities are usually located at fuel reprocessing sites (where the majority of the high level liquid wastes originates), the off-gas cleaning system should be designed so that the airborne radioactivity discharge of the whole site, including the emission of the waste conditioning facility, can be kept below the permitted limits. This report deals with the sources and composition of different kinds of high level liquid wastes and describes briefly the main high level liquid waste solidification processes examining the sources and characteristics of the off-gas contaminants to be retained by the off-gas cleaning system. The equipment and components of typical off-gas systems used in the most advanced (large pilot or industrial scale) high level liquid waste solidification plants are described. Safety considerations for the design and safe operation of the off-gas systems are discussed. 60 refs, 31 figs, 17 tabs

  2. High normal fasting glucose level in obese youth: a marker for insulin resistance and beta cell dysregulation.

    LENUS (Irish Health Repository)

    O'Malley, G

    2010-06-01

    A high but normal fasting plasma glucose level in adults is a risk factor for future development of type 2 diabetes mellitus and cardiovascular disease. We investigated whether normal fasting plasma glucose levels (<5.60 mmol\\/l) are associated with decreases in insulin sensitivity and beta cell function, as well as an adverse cardiovascular profile in obese youth.

  3. Comparison of self-esteem level of adolescents with cochlear implant and normal hearing.

    Science.gov (United States)

    Sahli, Sanem; Belgin, Erol

    2006-09-01

    The purpose of this study is to compare the levels of self-esteem of adolescents with cochlear implants (before and after cochlear implantation) and the ones who have normal hearing. For this purpose, Rosenberg self-esteem scale is applied upon the study group which consists of 30 adolescents with cochlear implant between the ages of 12-19 and upon the control group which consists of 60 adolescents having the similar characteristics. The scale is used to evaluate the level of self-esteem of adolescents with cochlear implant and with normal hearing. At the end of the application, the scores of these two groups which they got according to their answers were compared statistically. When the results were examined, there seemed to be no significant difference statistically between the self-esteem values of the cochlear implant group and the control group. Apart from this, there seemed to be significant difference statistically between the self-esteem values of the before cochlear implantation and control group. In this study, we examined changes in the level of self-esteem according to different variables. As a result, it was found out that in both groups levels of self-esteem was higher for adolescents who had had preschool education, had brothers/sisters, high level of income, whose mother was working and whose father and mother had higher levels of education. On the other hand, the birth sequence and the child's father's profession did not seem to have any effect on the child's level of self-esteem. As a result of these findings, it was thought that cochlear implantation had a positive effect on life quality and it was suggested that the adolescents and their families should get assistance from experts about the characteristics and principles of approaching the child in this period. The adolescent should be directed towards social activities and courses, their positive sides should be supported and further studies should be carried out with different case groups on

  4. EEG responses to low-level chemicals in normals and cacosmics.

    Science.gov (United States)

    Schwartz, G E; Bell, I R; Dikman, Z V; Fernandez, M; Kline, J P; Peterson, J M; Wright, K P

    1994-01-01

    Recent studies from the University of Arizona indicate that normal subjects, both college students and the elderly, can register the presence of low-intensity odors in the electroencephalogram (EEG) in the absence of conscious awareness of the odors. The experimental paradigm involves subjects sniffing pairs of bottles, one containing an odorant (e.g. isoamyl acetate) dissolved in an odorless solvent (water or liquid silicone), the other containing just the solvent, while 19 channels of EEG are continuously recorded. For the low-intensity odor conditions, concentrations are adjusted downward (decreased) until subjects correctly identify the odor bottle at chance (50%). The order of odorants, concentrations, and hand holding the control bottle, are counterbalanced within and across subjects. Three previous experiments found that alpha activity (8-12 hz) decreased in midline and posterior regions when subjects sniffed the low-intensity odors. The most recent study suggests that decreased theta activity (4-8 hz) may reflect sensory registration and decreased alpha activity may reflect perceptual registration. In a just completed experiment involving college students who were selected based on combinations of high and low scores on a scale measuring cacosmia (chemical odor intolerance) and high and low scores on a scale measuring depression, cacosmic subjects (independent of depression) showed greater decreases in low-frequency alpha (8-10 hz) and greater increases in low-frequency beta (12-16 hz) to the solvent propylene glycol compared to an empty bottle. Topographic EEG mapping to low-intensity odorants may provide a useful tool for investigating possible increased sensitivity to specific chemicals in chemically sensitive individuals.

  5. Mucous solids and liquid secretion by airways: studies with normal pig, cystic fibrosis human, and non-cystic fibrosis human bronchi

    Science.gov (United States)

    Martens, Chelsea J.; Inglis, Sarah K.; Valentine, Vincent G.; Garrison, Jennifer; Conner, Gregory E.

    2011-01-01

    To better understand how airways produce thick airway mucus, nonvolatile solids were measured in liquid secreted by bronchi from normal pig, cystic fibrosis (CF) human, and non-CF human lungs. Bronchi were exposed to various secretagogues and anion secretion inhibitors to induce a range of liquid volume secretion rates. In all three groups, the relationship of solids concentration (percent nonvolatile solids) to liquid volume secretion rate was curvilinear, with higher solids concentration associated with lower rates of liquid volume secretion. In contrast, the secretion rates of solids mass and water mass as functions of liquid volume secretion rates exhibited positive linear correlations. The y-intercepts of the solids mass-liquid volume secretion relationships for all three groups were positive, thus accounting for the higher solids concentrations in airway liquid at low rates of secretion. Predictive models derived from the solids mass and water mass linear equations fit the experimental percent solids data for the three groups. The ratio of solids mass secretion to liquid volume secretion was 5.2 and 2.4 times higher for CF bronchi than for pig and non-CF bronchi, respectively. These results indicate that normal pig, non-CF human, and CF human bronchi produce a high-percent-solids mucus (>8%) at low rates of liquid volume secretion (≤1.0 μl·cm−2·h−1). However, CF bronchi produce mucus with twice the percent solids (∼8%) of pig or non-CF human bronchi at liquid volume secretion rates ≥4.0 μl·cm−2·h−1. PMID:21622844

  6. Normal dietary levels of radium-226, radium-228, lead-210, and polonium-210 for man

    International Nuclear Information System (INIS)

    Holtzman, R.B.

    1980-01-01

    A review of the literature and the results of some recent measurements on the levels in man's diet of the naturally occurring radionuclides 226 Ra, 228 Ra, 210 Pb, and 210 Po are presented. Intakes in other countries are similar to those in the United States, but in localized populations the 226 Ra intake can be 8 or more pCi/day. The few data on 228 Ra show that intake of this nuclide is about 80% that of 226 Ra except in monazite areas where intakes of up to 160 pCi 228 Ra/day are reported. Drinking water contributes less than 5% to daily intake except in special areas. For 210 Pb, higher levels have been noted for Germany and the Union of Soviet Socialist Republics than for the United States. Persons in the Arctic who consume reindeer or caribou meat may ingest 210 Pb at the rate of 10 to 40 pCi/day. Normal dietary levels of 210 Po are about 20 to 30% higher than those of 210 Pb, except in the Arctic. The levels of these nuclides in classes of foods are compared to show that the higher levels observed in certain diets are due to the levels in particular foods. Because of the high levels of 210 Pb intake in Japan, total skeletal dose rates in that country are estimated to be more than twice those in the United States. The use of dietary intake for estimating metabolic parameters, such as intestinal absorption of 226 Ra and 210 Pb, is discussed

  7. Cross flow filtration of Oak Ridge National Laboratory liquid low-level waste

    International Nuclear Information System (INIS)

    Fowler, V.L.; Hewitt, J.D.

    1989-12-01

    A new method for disposal of Oak Ridge National Laboratory liquid low-level radioactive waste is being developed as an alternative to hydrofracture. The acceptability of the final waste form rests in part on the presence or absence of transuranic (TRU) isotopes. Inertial cross flow filtration was used in this study to determine the potential of this method for separation of the TRU isotopes from the bulk liquid stored in the Melton Valley Storage Tanks. 7 refs., 11 figs., 5 tabs

  8. Status of the NA62 liquid krypton electromagnetic calorimeter Level 0 trigger processor

    CERN Document Server

    Bonaiuto, V; Fucci, A; Paoluzzi, G; Salamon, A; Salina, G; Santovetti, E; Sargeni, F; Venditti, S

    2013-01-01

    The NA62 experiment at the CERN SPS aims to measure the Branching Ratio of the very rare kaon decay K(+)→π(+)νbar nu collecting O(100) events with a 10% background in two years of data taking. To reject the K(+)→π(+)π(0) background the NA48 liquid krypton calorimeter will be used in the 1-10 mrad angular region. The status of the Liquid Krypton Electromagnetic Calorimeter Level 0 Trigger is presented.

  9. State-of-the-art for liquid-level measurements applied to in-vessel coolant level for nuclear reactors

    International Nuclear Information System (INIS)

    Anderson, R.L.

    1980-01-01

    The TMI-2 accident indicated that a direct indication of the liquid level in the reactor vessel would have told the operators that the core was being uncovered. This state-of-the-cost survey covered the following methods: heated thermocouple, differential pressure, ultrasonic, capacitance, microwave, time-domain reflectometry, and externally mounted radiation detectors

  10. Development of the liquid level meters for the PandaX dark matter detector

    International Nuclear Information System (INIS)

    Hu Jie; Gong Haowei; Lin Qing; Ni Kaixuan; Wei Yuehuan; Xiao Mengjiao; Xiao Xiang; Zhao Li; Tan Andi

    2014-01-01

    The two-phase xenon detector is at the frontier of dark matter direct search. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level needs to be monitored and controlled in sub-millimeter precision. In this paper, we present a detailed design and study of two kinds of level meters for the PandaX dark matter detector. The long level meter is used to monitor the overall liquid level while short level meters are used to monitor the inclination of the detector. These level meters are cylindrical capacitors that are custom-made from two concentric metal tubes. Their capacitance values are read out by a universal transducer interface chip and are recorded by the PandaX slow control system. We present the developments that lead to level meters with long-term stability and sub-millimeter precision. Fluctuations (standard deviations) of less than 0.02 mm for the short level meters and less than 0.2 mm for the long level meter were achieved during a few days of test operation. (authors)

  11. Plasma levels of norepinephrine during the periovulatory period in normal women

    International Nuclear Information System (INIS)

    Badano, A.R.; Nagle, C.A.; Casas, P.R.F.; Miechi, H.; Mirkin, A.; Turner, D.E.; Aparicio, N.; Rosner, J.M.

    1978-01-01

    Eleven normally cycling women in whom laparotomy was indicated for benign gynecologic pathology were studied. Surgery was performed on day 0 (expected day of ovulation). Blood samples were drawn daily from day -8 to day -4, and every 8 hours from day -3 to day +2; estradiol (E 2 ), progesterone (P), norepinephrine (NE), and LH were determined by RIA. Ovulation was certified by ovarian visualization and biopsy during laparotomy. In nine ovulatory patients mean E 2 peak was found 48 hours before LH peak. Mean NE levels showed minimal variations until 48 hours before LH peak; 8 hours after E 2 peak mean NE values increased significantly, fell 8 hours later, and rose immediately again, reaching maximal levels 24 hours after E 2 peak. These values remained high until 16 hours before the LH peak and decreased gradully, thereafter reaching basal levels 32 hours after LH peak. Two anovulatory patients showed an atypical pattern of ovarian steroids and LH secretion and NE showed large variations without any correlation with estradiol or LH levels. This study confirms previous findings in women and experimental work in animals regarding the existence of a noradrenergic trigger mechanism to the LH ovulatory discharge

  12. EGSIEM combination service: combination of GRACE monthly K-band solutions on normal equation level

    Science.gov (United States)

    Meyer, Ulrich; Jean, Yoomin; Arnold, Daniel; Jäggi, Adrian

    2017-04-01

    The European Gravity Service for Improved Emergency Management (EGSIEM) project offers a scientific combination service, combining for the first time monthly GRACE gravity fields of different analysis centers (ACs) on normal equation (NEQ) level and thus taking all correlations between the gravity field coefficients and pre-eliminated orbit and instrument parameters correctly into account. Optimal weights for the individual NEQs are commonly derived by variance component estimation (VCE), as is the case for the products of the International VLBI Service (IVS) or the DTRF2008 reference frame realisation that are also derived by combination on NEQ-level. But variance factors are based on post-fit residuals and strongly depend on observation sampling and noise modeling, which both are very diverse in case of the individual EGSIEM ACs. These variance factors do not necessarily represent the true error levels of the estimated gravity field parameters that are still governed by analysis noise. We present a combination approach where weights are derived on solution level, thereby taking the analysis noise into account.

  13. Impact of Millimeter-Level Margins on Peripheral Normal Brain Sparing for Gamma Knife Radiosurgery

    International Nuclear Information System (INIS)

    Ma, Lijun; Sahgal, Arjun; Larson, David A.; Pinnaduwage, Dilini; Fogh, Shannon; Barani, Igor; Nakamura, Jean; McDermott, Michael; Sneed, Penny

    2014-01-01

    Purpose: To investigate how millimeter-level margins beyond the gross tumor volume (GTV) impact peripheral normal brain tissue sparing for Gamma Knife radiosurgery. Methods and Materials: A mathematical formula was derived to predict the peripheral isodose volume, such as the 12-Gy isodose volume, with increasing margins by millimeters. The empirical parameters of the formula were derived from a cohort of brain tumor and surgical tumor resection cavity cases (n=15) treated with the Gamma Knife Perfexion. This was done by first adding margins from 0.5 to 3.0 mm to each individual target and then creating for each expanded target a series of treatment plans of nearly identical quality as the original plan. Finally, the formula was integrated with a published logistic regression model to estimate the treatment-induced complication rate for stereotactic radiosurgery when millimeter-level margins are added. Results: Confirmatory correlation between the nominal target radius (ie, R T ) and commonly used maximum target size was found for the studied cases, except for a few outliers. The peripheral isodose volume such as the 12-Gy volume was found to increase exponentially with increasing Δ/R T , where Δ is the margin size. Such a curve fitted the data (logarithmic regression, R 2 >0.99), and the 12-Gy isodose volume was shown to increase steeply with a 0.5- to 3.0-mm margin applied to a target. For example, a 2-mm margin on average resulted in an increase of 55% ± 16% in the 12-Gy volume; this corresponded to an increase in the symptomatic necrosis rate of 6% to 25%, depending on the Δ/R T values for the target. Conclusions: Millimeter-level margins beyond the GTV significantly impact peripheral normal brain sparing and should be applied with caution. Our model provides a rapid estimate of such an effect, particularly for large and/or irregularly shaped targets

  14. Eldecalcitol normalizes bone turnover markers regardless of their pre-treatment levels.

    Science.gov (United States)

    Shiraki, Masataka; Saito, Hitoshi; Matsumoto, Toshio

    2012-09-01

    Three-year treatment with eldecalcitol has been shown to improve lumbar and total hip bone mineral density (BMD), decrease bone turnover markers, and lower the incidences of vertebral and wrist fractures in patients with osteoporosis more than with treatment with alfacalcidol under vitamin D repletion. The purpose of this study was to determine whether there was a risk of eldecalcitol causing severely suppressed bone turnover in osteoporosis patients with low pre-treatment levels of bone turnover markers. Post-hoc analysis was conducted on the data from a 3-year, randomized, double-blind, active-comparator, clinical trial of eldecalcitol versus alfacalcidol under vitamin D repletion conducted in Japan. Enrolled patients with baseline measurements of bone turnover markers were stratified into tertiles according to their pre-treatment levels of serum bone-specific alkaline phosphatase, serum procollagen type I N-terminal propeptide, or urinary collagen-N-telopeptide. Eldecalcitol treatment rapidly reduced bone turnover markers, and kept them within the normal range. However, in the patients whose baseline values for bone turnover were low, eldecalcitol treatment did not further reduce bone turnover markers during the 3-year treatment period. Further long-term observation may be required to reach the conclusion. CLINICALTRIALS.GOV NUMBER: NCT00144456. Eldecalcitol normalizes, but does not overly suppress, bone turnover regardless of baseline levels of bone turnover markers. Thus, it is unlikely that eldecalcitol treatment will increase the risk of severely suppressed bone turnover and therefore deterioration of bone quality, at least for a treatment duration of 3 years.

  15. Automated Liquid-Level Control of a Nutrient Reservoir for a Hydroponic System

    Science.gov (United States)

    Smith, Boris; Asumadu, Johnson A.; Dogan, Numan S.

    1997-01-01

    A microprocessor-based system for control of the liquid level of a nutrient reservoir for a plant hydroponic growing system has been developed. The system uses an ultrasonic transducer to sense the liquid level or height. A National Instruments' Multifunction Analog and Digital Input/Output PC Kit includes NI-DAQ DOS/Windows driver software for an IBM 486 personal computer. A Labview Full Development system for Windows is the graphical programming system being used. The system allows liquid level control to within 0.1 cm for all levels tried between 8 and 36 cm in the hydroponic system application. The detailed algorithms have been developed and a fully automated microprocessor based nutrient replenishment system has been described for this hydroponic system.

  16. Simulation of Water Level Fluctuations in a Hydraulic System Using a Coupled Liquid-Gas Model

    Directory of Open Access Journals (Sweden)

    Chao Wang

    2015-08-01

    Full Text Available A model for simulating vertical water level fluctuations with coupled liquid and gas phases is presented. The Preissmann implicit scheme is used to linearize the governing equations for one-dimensional transient flow for both liquid and gas phases, and the linear system is solved using the chasing method. Some classical cases for single liquid and gas phase transients in pipelines and networks are studied to verify that the proposed methods are accurate and reliable. The implicit scheme is extended using a dynamic mesh to simulate the water level fluctuations in a U-tube and an open surge tank without consideration of the gas phase. Methods of coupling liquid and gas phases are presented and used for studying the transient process and interaction between the phases, for gas phase limited in a chamber and gas phase transported in a pipeline. In particular, two other simplified models, one neglecting the effect of the gas phase on the liquid phase and the other one coupling the liquid and gas phases asynchronously, are proposed. The numerical results indicate that the asynchronous model performs better, and are finally applied to a hydropower station with surge tanks and air shafts to simulate the water level fluctuations and air speed.

  17. Development of a test system for high level liquid waste partitioning

    Directory of Open Access Journals (Sweden)

    Duan Wu H.

    2015-01-01

    Full Text Available The partitioning and transmutation strategy has increasingly attracted interest for the safe treatment and disposal of high level liquid waste, in which the partitioning of high level liquid waste is one of the critical technical issues. An improved total partitioning process, including a tri-alkylphosphine oxide process for the removal of actinides, a crown ether strontium extraction process for the removal of strontium, and a calixcrown ether cesium extraction process for the removal of cesium, has been developed to treat Chinese high level liquid waste. A test system containing 72-stage 10-mm-diam annular centrifugal contactors, a remote sampling system, a rotor speed acquisition-monitoring system, a feeding system, and a video camera-surveillance system was successfully developed to carry out the hot test for verifying the improved total partitioning process. The test system has been successfully used in a 160 hour hot test using genuine high level liquid waste. During the hot test, the test system was stable, which demonstrated it was reliable for the hot test of the high level liquid waste partitioning.

  18. Effect of Low-Level Laser Stimulation on EEG Power in Normal Subjects with Closed Eyes

    Directory of Open Access Journals (Sweden)

    Jih-Huah Wu

    2013-01-01

    Full Text Available In a previous study, we found that the low-level laser (LLL stimulation at the palm with a frequency of 10 Hz was able to induce significant brain activation in normal subjects with opened eyes. However, the electroencephalography (EEG changes to LLL stimulation in subjects with closed eyes have not been studied. In the present study, the laser array stimulator was applied to deliver insensible laser stimulations to the palm of the tested subjects with closed eyes (the laser group. The EEG activities before, during, and after the laser stimulation were collected. The EEG amplitude powers of each EEG frequency band at 19 locations were calculated. These power data were then analyzed by SPSS software using repeated-measure ANOVAs and appropriate posthoc tests. We found a pronounced decrease in the EEG power in alpha-bandwidth during laser simulation and then less decrease in the EEG power in delta-bandwidth in normal subjects with laser stimulation. The EEG power in beta-bandwidth in the right occipital area also decreased significantly in the laser group. We suggest that LLL stimulation might be conducive to falling into sleep in patients with sleep problems.

  19. Neutron and PIMC determination of the longitudinal momentum distribution of HCP, BCC and normal liquid 4He

    International Nuclear Information System (INIS)

    Blasdell, R.C.; Ceperley, D.M.; Simmons, R.O.

    1993-07-01

    Deep inelastic neutron scattering has been used to measure the neutron Compton profile (NCP) of a series of condensed 4 He samples at densities from 28.8 atoms/nm 3 (essentially the minimum possible density in the solid phase) up to 39.8 atoms/nm 3 using a chopper spectrometer at the Argonne National Laboratory Intense Pulsed Neutron Source. At the lowest density, the NCP was measured along an isochore through the hcp, bcc, and normal liquid phases. Average atomic kinetic energies are extracted from each of the data sets and are compared to both published and new path integral Monte-Carlo (PIMC) calculations as well as other theoretical predictions. In this preliminary analysis of the data, account is taken of the effects of instrumental resolution, multiple scattering, and final-state interactions. Both our measurements and the PIMC theory show that there are only small differences in the kinetic energy and longitudinal momentum distribution of isochoric helium samples, regardless of their phase or crystal structure

  20. Actinides and fission products partitioning from high level liquid waste

    International Nuclear Information System (INIS)

    Yamaura, Mitiko

    1999-01-01

    The presence of small amount of mixed actinides and long-lived heat generators fission products as 137 Cs and 90 Sr are the major problems for safety handling and disposal of high level nuclear wastes. In this work, actinides and fission products partitioning process, as an alternative process for waste treatment is proposed. First of all, ammonium phosphotungstate (PWA), a selective inorganic exchanger for cesium separation was chosen and a new procedure for synthesizing PWA into the organic resin was developed. An strong anionic resin loaded with tungstate or phosphotungstate anion enables the precipitation of PWA directly in the resinous structure by adding the ammonium nitrate in acid medium (R-PWA). Parameters as W/P ratio, pH, reactants, temperature and aging were studied. The R-PWA obtained by using phosphotungstate solution prepared with W/P=9.6, 9 hours digestion time at 94-106 deg C and 4 to 5 months aging time showed the best capacity for cesium retention. On the other hand, Sr separation was performed by technique of extraction chromatography, using DH18C6 impregnated on XAD7 resin as stationary phase. Sr is selectively extracted from acid solution and >99% was recovered from loaded column using distilled water as eluent. Concerning to actinides separations, two extraction chromatographic columns were used. In the first one, TBP(XAD7) column, U and Pu were extracted and its separations were carried-out using HNO 3 and hydroxylamine nitrate + HNO 3 as eluent. In the second one, CMP0-TBP(XAD7) column, the actinides were retained on the column and the separations were done by using (NH 4 ) 2 C 2 O 4 , DTPA, HNO 3 and HCl as eluent. The behavior of some fission products were also verified in both columns. Based on the obtained data, actinides and fission products Cs and Sr partitioning process, using TBP(XAD7) and CMP0-TBP(XAD7) columns for actinides separation, R-PWA column for cesium retention and DH18C6(XAD7) column for Sr isolation was performed

  1. Diet enriched with fresh coconut decreases blood glucose levels and body weight in normal adults.

    Science.gov (United States)

    Vijayakumar, Venugopal; Shankar, Nagashree R; Mavathur, Ramesh; Mooventhan, A; Anju, Sood; Manjunath, N K

    2018-02-20

    Background There exist controversies about the health effects of coconut. Fresh coconut consumption on human health has not been studied substantially. Fresh coconut consumption is a regular part of the diet for many people in tropical countries like India, and thus there is an increasing need to understand the effects of fresh coconut on various aspects of health. Aim To compare the effects of increased saturated fatty acid (SFA) and fiber intake, provided by fresh coconut, versus monounsaturated fatty acid (MUFA) and fiber intake, provided by a combination of groundnut oil and groundnuts, on anthropometry, serum insulin, glucose levels and blood pressure in healthy adults. Materials Eighty healthy volunteers, randomized into two groups, were provided with a standardized diet along with either 100 g fresh coconut or an equivalent amount of groundnuts and groundnut oil for a period of 90 days. Assessments such as anthropometric measurements, blood pressure, blood sugar and insulin levels were performed before and after the supplementation period. Results Results of this study showed a significant reduction in fasting blood sugar (FBS) in both the groups. However, a significant reduction in body weight was observed in the coconut group, while a significant increase in diastolic pressure was observed in the groundnut group. Conclusions Results of this study suggest that fresh coconut-added diet helps reduce blood glucose levels and body weight in normal healthy individuals.

  2. Comparison of Serum Vit D Level Between Psoriasis Patients and Normal Population

    Directory of Open Access Journals (Sweden)

    A. Darjani

    2016-11-01

    Full Text Available Introduction: Psoriasis is a common inflammatory skin disorder with humeral and cellular immune system involvement. On the other hands، Vitamin D has important immunomodulatory effects and its relations with many autoimmune diseases were shown. The relation between Serum Vit D Level and Psoriasis disease remained controversial issue that this study was done to show this relationship. Methods and Materials: In this comparative cross sectional study، 30 psoriatic patients who attended to Razi dermatology clinic in Rasht، by sequential sampling underwent study as case group. 30 healthy people from hospital at the same age، gender and skin-colored also were selected as control group. Inclusion criteria were patients and people without Ca or Vit D supplements usage or underground diseases in relation to hypovitaminosis D. Demographical data were gathered by interviewing and then blood samples from all participants were sent for analysis of serum Ca، P، Vit D and parathormone level. Data analysis was done by SPSS ver. 18 using T-test and Chi 2 test. Result: Mean and SD serum level of Vit D in case and control groups were 25.8± 12.6 ng/ mL and  23.7± 8.9 ng/ mL، respectively (ρ>0.05. Out of all، 24 participants (40% suffered from Vit D Deficiency and 20 people (33.3% from Vit D insufficiency ، only 26.7% study subjects had acceptable serum Vit D level. There were not any significant difference between Vit D deficiency rates and other measured biochemical indices in two groups (36.7% vs. 43.3%. Conclusion: This study showed high level of Vit D deficiency in both psoriatic and normal people that must be notice.

  3. High sensitivity optical fiber liquid level sensor based on a compact MMF-HCF-FBG structure

    Science.gov (United States)

    Zhang, Yunshan; Zhang, Weigang; Chen, Lei; Zhang, Yanxin; Wang, Song; Yan, Tieyi

    2018-05-01

    An ultra-high sensitivity fiber liquid level sensor based on wavelength demodulation is proposed and demonstrated. The sensor is composed of a segment of multimode fiber and a large aperture hollow-core fiber assisted by a fiber Bragg grating (FBG). Interference occurs due to core mismatching and different modes with different effective refractive indices. The experimental results show that the liquid level sensitivity of the sensor is 1.145 nm mm‑1, and the linearity is up to 0.996. The dynamic temperature compensation of the sensor can be achieved by cascading an FBG. Considering the high sensitivity and compact structure of the sensor, it can be used for real-time intelligent monitoring of tiny changes in liquid level.

  4. Filtration of Oak Ridge National Laboratory simulated liquid low-level waste

    International Nuclear Information System (INIS)

    Fowler, V.L.; Hewitt, J.D.

    1989-08-01

    A method for disposal of Oak Ridge National Laboratory's (ORNL's) liquid low-level radioactive waste (LLLW) is being developed in which the material will be solidified in cement and stored in an aboveground engineered storage facility. The acceptability of the final waste form rests in part on the presence or absence of transuranic isotopes. Filtration methods to remove transuranic isotopes from the bulk liquid stored in the Melton Valley Storage Tanks (MVST) were investigated in this study. Initial batch studies using waste from MVST indicate that >99.9% of the transuranic isotopes can be removed from the bulk liquid by simple filtration. Bench-scale studies with a nonradioactive surrogate waste indicate that >99.5% of the suspended solids can be removed from the bulk liquid via inertial crossflow filtration. 4 refs., 3 figs., 11 tabs

  5. Liquid chromatography tandem mass spectrometry determination of total budesonide levels in dog plasma after inhalation exposure.

    Science.gov (United States)

    Berg, Seija; Melamies, Marika; Rajamäki, Minna; Vainio, Outi; Peltonen, Kimmo

    2012-01-01

    A sensitive and selective method to quantify budesonide in dog plasma samples was developed and fully validated. Liquid-liquid extraction was followed by solid-phase extraction and liquid chromatography-tandem mass spectrometry with electrospray ionization. After reconstitution of the analytes in the mobile phase, samples were analysed by reversed-phase liquid chromatography with isocratic elution. d8-Budesonide was used as an internal standard, and characteristic transitions of d8-budesonide and budesonide were used for quantification. The method was validated with respect to selectivity, specificity, linearity, recovery, repeatability, reproducibility and limits of detection and quantification. The validated method was successfully applied to monitor the plasma levels of budesonide in dogs exposed to clinical doses of inhaled and intravenous drug.

  6. Increased levels of circulating arginase I in overweight compared to normal weight adolescents.

    Science.gov (United States)

    Jung, Christian; Figulla, Hans R; Lichtenauer, Michael; Franz, Marcus; Pernow, John

    2014-02-01

    Overweight and the metabolic syndrome have become major problems, especially in children and adolescents. Obesity at a young age increases the risk for cardiovascular diseases and diabetes mellitus later in life. An early event in the development of cardiovascular disease is endothelial dysfunction which is found in obese young individuals. Increased activity of the enzyme arginase has been described as a central mechanism for endothelial dysfunction, especially in patients with diabetes mellitus. The aim of the study was to determine plasma levels of arginase in overweight adolescents. Sixty-six male German adolescents (age: 15.2 ± 1.1 years old) were included. Thirty-one of them were overweight (>90th age-specific weight percentile). Plasma arginase I and tumor necrosis factor alpha (TNFα) were determined. In addition, clinical data were recorded and anthropometrical measurements of obesity were performed. Overweight adolescents had a higher systolic blood pressure, lower high-density lipoprotein and increased levels of high-sensitive C-reactive protein (CRP). Circulating arginase I was elevated in overweight adolescents (95.8 ± 68.2 ng/ml) compared to normal weight adolescents (39.3 ± 26.9 ng/ml, p obesity. There was no difference between the two groups regarding TNFα. We demonstrate that arginase I levels are increased in obese adolescents. Knowing the important role for arginase in endothelial dysfunction, elevated levels of arginase I may represent a link between obesity, endothelial dysfunction and related comorbidities. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Research and Development of Solar Evaporation on Low Level Radioactive Liquid Waste

    Directory of Open Access Journals (Sweden)

    ZHANG Hua

    2016-02-01

    Full Text Available Solar evaporation, which can save energy and obtain the higher decontamination factor, the larger treatment capability with the simpler designed and easy operation, was one of the general methods to treat low level radioactive liquid waste. However, the use of solar evaporation was limited because the facilities had to occupy the larger area and require sunshine for the longer duration, etc. Several cases form USA, Australian, India and South Korea were presented on R&D of solar evaporation to treat low level radioactive liquid waste.

  8. Solvent extraction in the treatment of acidic high-level liquid waste : where do we stand?

    International Nuclear Information System (INIS)

    Horwitz, E. P.; Schulz, W. W.

    1998-01-01

    During the last 15 years, a number of solvent extraction/recovery processes have been developed for the removal of the transuranic elements, 90 Sr and 137 Cs from acidic high-level liquid waste. These processes are based on the use of a variety of both acidic and neutral extractants. This chapter will present an overview and analysis of the various extractants and flowsheets developed to treat acidic high-level liquid waste streams. The advantages and disadvantages of each extractant along with comparisons of the individual systems are discussed

  9. Single uniform FBG for simultaneous measurement of liquid level and temperature

    International Nuclear Information System (INIS)

    Shu, Xuewen; Sugden, Kate; Bennion, Ian

    2010-01-01

    In this paper, we propose and demonstrate a novel scheme for simultaneous measurement of liquid level and temperature based on a simple uniform fiber Bragg grating (FBG) by monitoring both the short-wavelength-loss peaks and its Bragg resonance. The liquid level can be measured from the amplitude changes of the short-wavelength-loss peaks, while temperature can be measured from the wavelength shift of the Bragg resonance. Both theoretical simulation results and experimental results are presented. Such a scheme has some advantages including robustness, simplicity, flexibility in choosing sensitivity and simultaneous temperature measurement capability

  10. Large-scale event extraction from literature with multi-level gene normalization.

    Directory of Open Access Journals (Sweden)

    Sofie Van Landeghem

    Full Text Available Text mining for the life sciences aims to aid database curation, knowledge summarization and information retrieval through the automated processing of biomedical texts. To provide comprehensive coverage and enable full integration with existing biomolecular database records, it is crucial that text mining tools scale up to millions of articles and that their analyses can be unambiguously linked to information recorded in resources such as UniProt, KEGG, BioGRID and NCBI databases. In this study, we investigate how fully automated text mining of complex biomolecular events can be augmented with a normalization strategy that identifies biological concepts in text, mapping them to identifiers at varying levels of granularity, ranging from canonicalized symbols to unique gene and proteins and broad gene families. To this end, we have combined two state-of-the-art text mining components, previously evaluated on two community-wide challenges, and have extended and improved upon these methods by exploiting their complementary nature. Using these systems, we perform normalization and event extraction to create a large-scale resource that is publicly available, unique in semantic scope, and covers all 21.9 million PubMed abstracts and 460 thousand PubMed Central open access full-text articles. This dataset contains 40 million biomolecular events involving 76 million gene/protein mentions, linked to 122 thousand distinct genes from 5032 species across the full taxonomic tree. Detailed evaluations and analyses reveal promising results for application of this data in database and pathway curation efforts. The main software components used in this study are released under an open-source license. Further, the resulting dataset is freely accessible through a novel API, providing programmatic and customized access (http://www.evexdb.org/api/v001/. Finally, to allow for large-scale bioinformatic analyses, the entire resource is available for bulk download from

  11. Fructose intake at current levels in the United States may cause gastrointestinal distress in normal adults.

    Science.gov (United States)

    Beyer, Peter L; Caviar, Elena M; McCallum, Richard W

    2005-10-01

    Fructose intake has increased considerably in the United States, primarily as a result of increased consumption of high-fructose corn syrup, fruits and juices, and crystalline fructose. The purpose was to determine how often fructose, in amounts commonly consumed, would result in malabsorption and/or symptoms in healthy persons. Fructose absorption was measured using 3-hour breath hydrogen tests and symptom scores were used to rate subjective responses for gas, borborygmus, abdominal pain, and loose stools. The study included 15 normal, free-living volunteers from a medical center community and was performed in a gastrointestinal specialty clinic. Subjects consumed 25- and 50-g doses of crystalline fructose with water after an overnight fast on separate test days. Mean peak breath hydrogen, time of peak, area under the curve (AUC) for breath hydrogen and gastrointestinal symptoms were measured during a 3-hour period after subjects consumed both 25- and 50-g doses of fructose. Differences in mean breath hydrogen, AUC, and symptom scores between doses were analyzed using paired t tests. Correlations among peak breath hydrogen, AUC, and symptoms were also evaluated. More than half of the 15 adults tested showed evidence of fructose malabsorption after 25 g fructose and greater than two thirds showed malabsorption after 50 g fructose. AUC, representing overall breath hydrogen response, was significantly greater after the 50-g dose. Overall symptom scores were significantly greater than baseline after each dose, but scores were only marginally greater after 50 g than 25 g. Peak hydrogen levels and AUC were highly correlated, but neither was significantly related to symptoms. Fructose, in amounts commonly consumed, may result in mild gastrointestinal distress in normal people. Additional study is warranted to evaluate the response to fructose-glucose mixtures (as in high-fructose corn syrup) and fructose taken with food in both normal people and those with

  12. An investigation of core liquid level depression in small break loss-of-coolant accidents

    International Nuclear Information System (INIS)

    Schultz, R.R.; Watkins, J.C.; Motley, F.E.; Stumpf, H.; Chen, Y.S.

    1991-08-01

    Core liquid level depression can result in partial core dryout and heatup early in a small break loss-of-coolant accident (SBLOCA) transient. Such behavior occurs when steam, trapped in the upper regions of the reactor primary system (between the loop seal and the core inventory), moves coolant out of the core region and uncovers the rod upper elevations. The net result is core liquid level depression. Core liquid level depression and subsequent core heatups are investigated using subscale data from the ROSA-IV Program's 1/48-scale Large Scale Test Facility (LSTF) and the 1/1705-scale Semiscale facility. Both facilities are Westinghouse-type, four-loop, pressurized water reactor simulators. The depression phenomena and factors which influence the minimum core level are described and illustrated using examples from the data. Analyses of the subject experiments, conducted using the TRAC-PF1/MOD1 (Version 12.7) thermal-hydraulic code, are also described and summarized. Finally, the response of a typical Westinghouse four-loop plant (RESAR-3S) was calculated to qualitatively study coal liquid level depression in a full-scale system. 31 refs., 37 figs., 6 tabs

  13. US and Russian innovative technologies to process low-level liquid radioactive wastes: The Murmansk initiative

    International Nuclear Information System (INIS)

    Dyer, R.S.; Duffey, R.B.; Penzin, R.; Sorlie, A.

    1996-01-01

    This paper documents the status of the technical design for the upgrade and expansion to the existing Low-level Liquid Radioactive Waste (LLLRW) treatment facility in Murmansk, the Russian Federation. This facility, owned by the Ministry of Transportation and operated by the Russian company RTP Atomflot in Murmansk, Russia, has been used by the Murmansk Shipping Company (MSCo) to process low-level liquid radioactive waste generated by the operation of its civilian icebreaker fleet. The purpose of the new design is to enable Russia to permanently cease the disposal at sea of LLLRW in the Arctic, and to treat liquid waste and high saline solutions from both the Civil and North Navy Fleet operations and decommissioning activities. Innovative treatments are to be used in the plant which are discussed in this paper

  14. Handling and storage of high-level liquid wastes from reprocessing of spent fuel

    International Nuclear Information System (INIS)

    Finsterwalder, L.

    1982-01-01

    The high level liquid wastes arise from the reprocessing of irradiated nuclear fuels, which are dissolved in aqueous acid solution, and the plutonium and unburned uranium removed in the chemical separation plant. The remaining solution, containing more than 99% of the dissolved fission products, together with impurities from cladding materials, corrosion products, traces of unseparated plutonium and uranium and most of the transuranic elements, constitutes the high-level waste. At present, these liquid wastes are usually concentrated by evaporation and stored as an aqueous nitric acid solution in high-integrity stainless-steel tanks. There is now world-wide agreement that, for the long term, these liquid wastes should be converted to solid form and much work is in progress to develop techniques for the solidification of these wastes. This paper considers the design requirements for such facilities and the experience gained during nearly 30 years of operation. (orig./RW)

  15. Advances in technologies for the treatment of low and intermediate level radioactive liquid wastes

    International Nuclear Information System (INIS)

    1994-01-01

    In recent years the authorized maximum limits for radioactive discharges into the environment have been reduced considerably, and this, together with the requirement to minimize the volume of waste for storage or disposal and to declassify some wastes from intermediate to low level or to non-radioactive wastes, has initiated studies of ways in which improvements can be made to existing decontamination processes and also to the development of new processes. This work has led to the use of more specific precipitants and to the establishment of ion exchange treatment and evaporation techniques. Additionally, the use of combinations of some existing processes or of an existing process with a new technique such as membrane filtration is becoming current practice. New biotechnological, solvent extraction and electrochemical methods are being examined and have been proven at laboratory scale to be useful for radioactive liquid waste treatment. In this report an attempt has been made to review the current research and development of mature and advanced technologies for the treatment of low and intermediate level radioactive liquid wastes, both aqueous and non-aqueous. Non-aqueous radioactive liquid wastes or organic liquid wastes typically consist of oils, reprocessing solvents, scintillation liquids and organic cleaning products. A brief state of the art of existing processes and their application is followed by the review of advances in technologies, covering chemical, physical and biological processes. 213 refs, 33 figs, 3 tabs

  16. Higher Fasting Plasma Glucose Levels, within the Normal Range, are Associated with Decreased Processing Speed in High Functioning Young Elderly

    OpenAIRE

    Raizes, Meytal; Elkana, Odelia; Franko, Motty; Springer, Ramit Ravona; Segev, Shlomo; Beeri, Michal Schnaider

    2016-01-01

    We explored the association of plasma glucose levels within the normal range with processing speed in high functioning young elderly, free of type 2 diabetes mellitus (T2DM). A sample of 41 participants (mean age = 64.7, SD = 10; glucose 94.5 mg/dL, SD = 9.3), were examined with a computerized cognitive battery. Hierarchical linear regression analysis showed that higher plasma glucose levels, albeit within the normal range (

  17. Temporary core liquid level depression during cold-leg small-break LOCA effect of break size and power level

    International Nuclear Information System (INIS)

    Koizumi, Y.; Kumamaru, H.; Mimura, Y.; Kukita, Y.; Tasaka, K.

    1989-01-01

    Cold-leg small break LOCA experiments (0.5-10% break) were conducted at the large scale test facility (LSTF), a volumetrically-scaled (1/48) simulator of a PWR, of the ROSA-IV Program. When a break area was less than 2.5% of the scaled cold-leg flow area, the core liquid level was temporarily further depressed to the bottom elevation of the crossover leg during the loop seal clearing early in the transient only by the manometric pressure balance since no coolant remained in the upper portion of the primary system. When the break size was larger than 5%, the core liquid level was temporarily further depressed lower than the bottom elevation of the crossover leg during the loop seal clearing since coolant remained at the upper portion of the primary system; the steam generator (SG) U-tube upflow side and the SG inlet plenum, due to counter current flow limiting by updrafting steam while the coolant drained. The amount of coolant trapped there was dependent on the vapor velocity (core power); the larger the core power, the lower the minimum core liquid level. The RELAP5/MOD2 code reasonable predicted phenomena observed in the experiments. (orig./DG)

  18. A new interface weak-capacitance detection ASIC of capacitive liquid level sensor in the rocket

    Science.gov (United States)

    Yin, Liang; Qin, Yao; Liu, Xiao-Wei

    2017-11-01

    A new capacitive liquid level sensing interface weak-capacitance detection ASIC has been designed. This ASIC realized the detection of the output capacitance of the capacitive liquid level sensor, which converts the output capacitance of the capacitive liquid level sensor to voltage. The chip is fabricated in a standard 0.5μm CMOS process. The test results show that the linearity of capacitance detection of the ASIC is 0.05%, output noise is 3.7aF/Hz (when the capacitance which will be detected is 40 pF), the stability of capacitance detection is 7.4 × 10-5pF (1σ, 1h), the output zero position temperature coefficient is 4.5 uV/∘C. The test results prove that this interface ASIC can meet the requirement of high accuracy capacitance detection. Therefore, this interface ASIC can be applied in capacitive liquid level sensing and capacitive humidity sensing field.

  19. Recent developments in the extraction separation method for treatment of high-level liquid waste

    International Nuclear Information System (INIS)

    Jiao Rongzhou; Song Chongli; Zhu Yongjun

    2000-01-01

    A description and review of the recent developments in the extraction separation method for partitioning transuranium elements from high-level liquid waste (HLLW) is presented. The extraction separation processes such as TRUEX process, DIAMEX process, DIDPA process, CTH process, TRPO process are briefly discussed

  20. Handling and storage of high-level radioactive liquid wastes requiring cooling

    International Nuclear Information System (INIS)

    1979-01-01

    The technology of high-level liquid wastes storage and experience in this field gained over the past 25 years are reviewed in this report. It considers the design requirements for storage facilities, describes the systems currently in use, together with essential accessories such as the transfer and off-gas cleaning systems, and examines the safety and environmental factors

  1. Ultrasonic instrument for continuous measurement of liquid levels in sodium systems

    International Nuclear Information System (INIS)

    Boehmer, L.S.

    1975-01-01

    An ultrasonic level measurement system which provides a continuous digital readout over a range of 3-180 inches, was tested in 500 0 F liquid sodium. The system proved to be accurate and reliable, required no initial warm-up period and experienced no long term drift. Modifications can extend the present operating temperatures to greater than 1200 0 F

  2. Laboratory simulation of high-level liquid waste evaporation and storage

    International Nuclear Information System (INIS)

    Anderson, P.A.

    1978-01-01

    The reprocessing of nuclear fuel generates high-level liquid wastes (HLLW) which require interim storage pending solidification. Interim storage facilities are most efficient if the HLLW is evaporated prior to or during the storage period. Laboratory evaporation and storage studies with simulated waste slurries have yielded data which are applicable to the efficient design and economical operation of actual process equipment

  3. Determination of the plutonium contamination level in biological samples by liquid scintillation

    International Nuclear Information System (INIS)

    Willemot, J.M.; Verry, M.; Lataillade, G.

    1989-01-01

    Usual radiochemical processes are unable to carry out without delay the very large number of analyses as required in plutonium toxicology studies. Liquid scintillation is the best method to quickly determine plutonium contamination levels in most various samples (bone, organs,...) [fr

  4. Balanced levels of nerve growth factor are required for normal pregnancy progression.

    Science.gov (United States)

    Frank, Pierre; Barrientos, Gabriela; Tirado-González, Irene; Cohen, Marie; Moschansky, Petra; Peters, Eva M; Klapp, Burghard F; Rose, Matthias; Tometten, Mareike; Blois, Sandra M

    2014-08-01

    Nerve growth factor (NGF), the first identified member of the family of neurotrophins, is thought to play a critical role in the initiation of the decidual response in stress-challenged pregnant mice. However, the contribution of this pathway to physiological events during the establishment and maintenance of pregnancy remains largely elusive. Using NGF depletion and supplementation strategies alternatively, in this study, we demonstrated that a successful pregnancy is sensitive to disturbances in NGF levels in mice. Treatment with NGF further boosted fetal loss rates in the high-abortion rate CBA/J x DBA/2J mouse model by amplifying a local inflammatory response through recruitment of NGF-expressing immune cells, increased decidual innervation with substance P(+) nerve fibres and a Th1 cytokine shift. Similarly, treatment with a NGF-neutralising antibody in BALB/c-mated CBA/J mice, a normal-pregnancy model, also induced abortions associated with increased infiltration of tropomyosin kinase receptor A-expressing NK cells to the decidua. Importantly, in neither of the models, pregnancy loss was associated with defective ovarian function, angiogenesis or placental development. We further demonstrated that spontaneous abortion in humans is associated with up-regulated synthesis and an aberrant distribution of NGF in placental tissue. Thus, a local threshold of NGF expression seems to be necessary to ensure maternal tolerance in healthy pregnancies, but when surpassed may result in fetal rejection due to exacerbated inflammation. © 2014 Society for Reproduction and Fertility.

  5. Saturation analysis studies of corticosteroid levels in normal Greek subjects and in subjects with haemolytic diseases

    International Nuclear Information System (INIS)

    Vyzantiadis, A.

    1975-07-01

    Between 1970 and 1974 a saturation analysis for cortisol in plasma and free cortisol in urine, and a radioimmunoassay method for aldosterone in plasma and urine were developed. In order to permit a comparative evaluation it was necessary to study corticosteroids, diurnal rhythm and the probable effect of a siesta on this rhythm both in normal subjects and in patients suffering from hemic diseases, in particular from sickle-cell anemia. Saturation assay for cortisol, using serum from pregnant women as source of transcortin, and radioimmunoassay for aldosterone were the basic methods used. Serum cortisol was estimated twice a day (8-9 a.m. and 5-6 p.m.). Cortisol and aldosterone were also estimated in serum and in urine before and after adrenalin stimulation with ACTH. No significant influence of a siesta on the diurnal rhythm of cortisol was observed, nor did the levels of serum cortisol or the diurnal rhythm appear affected in congenital hemolytic anemias, following adrenalin stimulation. The report lists experimental results briefly and refers to a paper in which these are published in more detail

  6. Plasma progranulin and relaxin levels in PCOS women with normal BMI compared to control healthy subjects

    Directory of Open Access Journals (Sweden)

    Samad Akbarzadeh

    2013-09-01

    Full Text Available Background: Poly Cystic Ovary Syndrome (PCOS is the most commonly encountered endocrine gland disease affecting 5-10 present of women at their reproductive age. This syndrome is associated with type 2 diabetes, dyslipidemia, and obesity. Progranulin and relaxin are adipokins that are related with carbohydrate and lipid metabolism. Due to limited data about progranulin and relaxin plasma levels´ in women with PCOS and normal BMI, this study was conducted. Material and Methods: This study is a cross-sectional. During the study 39 women with PCOS and BMI< 25 on the basis of Rotterdam criteria were chosen as the patient group and 38 healthy women were selected as the control group. The concentration of progranulin and relaxin were measured by ELISA technique. Results: The difference in Plasma concentration of progranulin and relaxin, and also some of the biochemical parameters in the patient group versus to the control group was not significant, but there was significant difference in the concentrations of VLDL, triglyceride (p=0.046, insulin (p=0.016, HOMA-IR (p=0.015, testosterone (p=0.01, and DHEAS (p=0.034 in the patients group compared to the control group. Conclusion: In this study, the difference in Plasma concentration of progranulin and relaxin in the patient group compared to the control group was not significant. It could be inferred that lack of change in plasma level of progranulin and relaxin in women with PCOS is related to BMI<25 and FBS<110. Moreoverestosterones, insulin, DHEAS and HOMA-IR changes could be better predictors of PCOS and its associated diabetes.

  7. Impact of Hypertriglyceridemia on Carotid Stenosis Progression under Normal Low-Density Lipoprotein Cholesterol Levels.

    Science.gov (United States)

    Kitagami, Masayuki; Yasuda, Ryuta; Toma, Naoki; Shiba, Masato; Nampei, Mai; Yamamoto, Yoko; Nakatsuka, Yoshinari; Sakaida, Hiroshi; Suzuki, Hidenori

    2017-08-01

    Dyslipidemia is a well-known risk factor for carotid stenosis progression, but triglycerides have attracted little attention. The aim of this study was to assess if serum triglycerides affect progression of carotid stenosis in patients with well-controlled low-density lipoprotein cholesterol (LDL-C) levels. This is a retrospective study in a single hospital consisting of 71 Japanese patients with internal carotid artery stenosis greater than or equal to 50% and normal serum LDL-C levels who underwent angiographic examination with or without the resultant carotid artery stenting or endarterectomy from 2007 to 2011, and were subsequently followed up for 4 years. Clinical factors including fasting serum triglyceride values were compared between the progression (≥10% increase in degree of carotid stenosis on ultrasonography) and the nonprogression groups. During 4 years, 15 patients (21.1%) had carotid stenosis progression on either side. Cox regression analysis demonstrated that symptomatic cases (hazard ratio [HR], 4.327; P = .019), coexisting intracranial arteriosclerotic stenosis (HR, 5.341; P = .005), and hypertriglyceridemia (HR, 6.228; P = .011) were associated with subsequent progression of carotid stenosis. Kaplan-Meier plots demonstrated that the progression-free survival rate was significantly higher in patients without hypertriglyceridemia and intracranial arteriosclerotic stenosis at baseline. Among patients with moderate to severe carotid stenosis and well-controlled LDL-C, hypertriglyceridemia was an important risk factor for progression of carotid stenosis irrespective of surgical treatments. It would be worthwhile to test if triglyceride-lowering medications suppress carotid stenosis progression. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  8. Liquid level measurement on coolant pipeline using Raman distributed temperature sensor

    International Nuclear Information System (INIS)

    Kasinathan, M.; Sosamma, S.; Babu Rao, C.; Murali, N.; Jayakumar, T.

    2011-01-01

    Optical fibre based Raman Distributed Temperature Sensor (RDTS) has been widely used for temperature monitoring in oil pipe line, power cable and environmental monitoring. Recently it has gained importance in nuclear reactor owing to its advantages like continuous, distributed temperature monitoring and immunity from electromagnetic interference. It is important to monitor temperature based level measurement in sodium capacities and in coolant pipelines for Fast Breeder Reactor (FBR). This particular application is used for filling and draining sodium in storage tank of sodium circuits of Fast breeder reactor. There are different conventional methods to find out the sodium level in the storage tank of sodium cooled reactors. They are continuous level measurement and discontinuous level measurement. For continuous level measurement, mutual inductance type level probes are used. The disadvantage of using this method is it needs a temperature compensation circuit. For discontinuous level measurement, resistance type discontinuous level probe and mutual inductance type discontinuous level probe are used. In resistance type discontinuous level probe, each level needs a separate probe. To overcome these disadvantages, RDTS is used for level measurement based distributed temperature from optical fibre as sensor. The feasibility of using RDTS for measurement of temperature based level measurement sensor is studied using a specially designed test set-up and using hot water, instead of sodium. The test set-up consist of vertically erected Stainless Steel (SS) pipe of length 2m and diameter 10cm, with provision for filling and draining out the liquid. Bare graded index multimode fibre is laid straight along the length of the of the SS pipe. The SS pipe is filled with hot water at various levels. The hot water in the SS pipe is maintained at constant temperature by insulating the SS pipe. The temperature profile of the hot water at various levels is measured using RDTS. The

  9. Phase behaviour of macromolecular liquid crystalline materials. Computational studies at the molecular level

    International Nuclear Information System (INIS)

    Stimson, Lorna M.

    2003-01-01

    Molecular simulations provide an increasingly useful insight into the static and dynamic characteristics of materials. In this thesis molecular simulations of macro-molecular liquid crystalline materials are reported. The first liquid crystalline material that has been investigated is a side chain liquid crystal polymer (SCLCP). In this study semi-atomistic molecular dynamics simulations have been conducted at a range of temperatures and an aligning potential has been applied to mimic the effect of a magnetic field. In cooling the SCLCP from an isotropic melt, microphase separation was observed yielding a domain structure. The application of a magnetic field to this structure aligns the domains producing a stable smectic mesophase. This is the first study in which mesophases have been observed using an off-lattice model of a SCLCP. The second material that has been investigated is a dendrimer with terminal mesogenic functionalization. Here, a multi-scale approach has been taken with Monte Carlo studies of a single dendrimer molecule in the gas phase at the atomistic level, semi-atomistic molecular dynamics of a single molecule in liquid crystalline solvents and a coarse-grained molecular dynamics study of the dendrimer in the bulk. The coarse-grained model has been developed and parameterized using the results of the atomistic and semi-atomistic work. The single molecule studies showed that the liquid crystalline dendrimer was able to change its structure by conformational changes in the flexible chains that link the mesogenic groups to the core. Structural change was seen under the application of a mean field ordering potential in the gas phase, and in the presence of liquid crystalline solvents. No liquid crystalline phases were observed for the bulk phase studies of the coarse-grained model. However, when the length of the mesogenic units was increased there was some evidence for microphase separation in these systems. (author)

  10. Removal of some Fission Products from Low Level Liquid Radioactive Waste by Chemical Precipitation liquid/Co-precipitation / Phosphate Coagulant

    International Nuclear Information System (INIS)

    Borai, E.H.; Attallah, M.F.; Hilal, M.A.; Abo-Aly, M.M.; Shehata, F.A.

    2008-01-01

    In Egypt radioactive waste has been generated from various uses of radioactive materials. Presence of cesium demonstrated a major problem from the removal point of view even by conventional and advanced technologies. Selective chemical precipitation has been oriented for removal of some fission products including 137 Cs from low level liquid radioactive waste (LLLRW). The aim of the present study was focused to investigate the effectiveness of various phosphate compounds that improved the precipitation process and hence the decontamination factor. The results showed that, maximum removal of 137 Cs reaching 46.4 % using di-sodium hydrogen phosphate as a selective coagulant. It was found that significant enhancement of co-precipitation of 137 Cs (62.5 %) was obtained due to presence of Nd 3+ in the LLLRW

  11. Stabilization and isolation of low-level liquid waste disposal sites

    International Nuclear Information System (INIS)

    Phillips, S.J.; Gilbert, T.W.

    1987-01-01

    Rockwell Hanford Operations is developing and testing equipment for stabilization and isolation of low-level radioactive liquid waste disposal sites. Stabilization and isolation are accomplished by a dynamic consolidation and particulate grout injection system. System equipment components include: a mobile grout plant for transport, mixing, and pumping of particulate grout; a vibratory hammer/extractor for consolidation of waste, backfill, and for emplacement of the injector; dynamic consolidation/injector probe for introducing grout into fill material; and an open-void surface injector that uses surface or subsurface mechanical or pneumatic packers and displacement gas filtration for introducing grout into disposal structure access piping. Treatment of a liquid-waste disposal site yields a physically stable, cementitious monolith. Additional testing and modification of this equipment for other applications to liquid waste disposal sites is in progress

  12. Fiber optic liquid-level sensor using a long fiber Bragg grating

    Science.gov (United States)

    Ricchiuti, Amelia L.; Barrera, David; Nonaka, Koji; Sales, Salvador

    2013-05-01

    A technique for liquid-level sensors based on a long fiber Bragg grating (FBG) is presented and experimentally demonstrated. The measurement system is based on the measurement of the central frequency distribution of the FBG based on time-frequency domain analysis. A short optical pulse is injected into a 10-cm long FBG mounted in a container. The back-reflected pulse is scanned by means of an oscilloscope. When part of the grating is immersed in a liquid having temperature higher than the surrounding ambient, the structure of the uniform grating is distorted and its time-frequency response changes. A spatial resolution of 2 mm, given by the input pulse duration, and a 10-cm long measurement range are achieved. Liquid-temperature sensing has also been implemented by scanning the spectral response of the FBG by means of a CW laser and an OSA.

  13. Functions and requirements document, WESF decoupling project, low-level liquid waste system

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, J.H., Fluor Daniel Hanford

    1997-02-27

    The Waste Encapsulation and Storage Facility (WESF) was constructed in 1974 to encapsulate and store cesium and strontium which were isolated at B Plant from underground storage tank waste. The WESF, Building 225-B, is attached physically to the west end of B Plant, Building 221-B, 200 East area. The WESF currently utilizes B Plant facilities for disposing liquid and solid waste streams. With the deactivation of B Plant, the WESF Decoupling Project will provide replacement systems allowing WESF to continue operations independently from B Plant. Four major systems have been identified to be replaced by the WESF Decoupling Project, including the following: Low Level Liquid Waste System, Solid Waste Handling System, Liquid Effluent Control System, and Deionized Water System.

  14. Clinical characteristics of hepatocellular carcinoma patients with normal serum alpha-fetoprotein level: A study of 112 consecutive cases.

    Science.gov (United States)

    Li, Li; Chen, Jinglong; Xu, Weiran; Ding, Xiaosheng; Wang, Xiangyi; Liang, Jun

    2017-10-26

    Serum alpha-fetoprotein (AFP) level is normal in 30-40% of hepatocellular carcinoma (HCC) patients, and knowledge on its characteristics and clinical outcome is limited. The purpose of this observational study was to determine the clinical presentation, biological behavior and outcome of HCC patients with normal AFP level. Data of 112 consecutive HCC patients with normal AFP level were analyzed retrospectively. Statistical analysis including survival and factors associated with serum AFP level were performed by Kaplan-Meier method and t-test, respectively. Hepatitis B virus infection exited in 83.0% of all 112 HCC patients with normal AFP level. During a mean 52 ± 20 months (range 5-85 months) follow-up, the 1-, 2-, 3-year overall survival (OS) rate was 97.2%, 85.3% and 81.7%, respectively. The OS rates at 3 years stratified by stages at diagnosis were 100%, 96.2%, 85.7%, 11.1% and 0%, respectively for Barcelona Clinic Liver Cancer (BCLC) stage 0-D diseases. Significant difference in OS was observed among patients with BCLC stage 0-D diseases, P level elevated beyond normal figure during follow-up (AFP conversion) in 16 patients, which related with deterioration of liver function, quantitative changes of T helper cell subsets, rapid tumor progression and shorter survival. Patients with sustained normal AFP level had better survival than patients with AFP conversion, P level elevation and the time of AFP elevation to death, P level was relatively optimal. Serum AFP level elevation during follow-up was significantly associated with clinical outcome in terms of OS. © 2017 John Wiley & Sons Australia, Ltd.

  15. Male aromatase-knockout mice exhibit normal levels of activity, anxiety and "depressive-like" symptomatology.

    Science.gov (United States)

    Dalla, C; Antoniou, K; Papadopoulou-Daifoti, Z; Balthazart, J; Bakker, J

    2005-09-08

    It is well known that estradiol derived from neural aromatization of testosterone plays a crucial role in the development of the male brain and the display of sexual behaviors in adulthood. It was recently found that male aromatase knockout mice (ArKO) deficient in estradiol due to a mutation in the aromatase gene have general deficits in coital behavior and are sexually less motivated. We wondered whether these behavioral deficits of ArKO males could be related to changes in activity, exploration, anxiety and "depressive-like" symptomatology. ArKO and wild type (WT) males were subjected to open field (OF), elevated plus maze (EPM), and forced swim tests (FST), after being exposed or not to chronic mild stress (CMS). CMS was used to evaluate the impact of chronic stressful procedures and to unveil possible differences between genotypes. There was no effect of genotype on OF, EPM and FST behavioral parameters. WT and ArKO mice exposed to CMS or not exhibited the same behavioral profile during these three types of tests. However, all CMS-exposed mice (ArKO and WT) spent less time in the center of the EPM. Additionally, floating duration measured in the FST increased between two tests in both WT and ArKO mice, though that increase was less prominent in mice previously subjected to CMS than in controls. Therefore, both ArKO and WT males displayed the same behavior and had the same response to CMS however CMS exposure slightly modified the behavior displayed by mice of both genotypes in the FST and EPM paradigms. These results show that ArKO males display normal levels of activity, exploration, anxiety and "depressive-like" symptomatology and thus their deficits in sexual behavior are specific in nature and do not result indirectly from other behavioral changes.

  16. A Neural Signature of Divisive Normalization at the Level of Multisensory Integration in Primate Cortex.

    Science.gov (United States)

    Ohshiro, Tomokazu; Angelaki, Dora E; DeAngelis, Gregory C

    2017-07-19

    Studies of multisensory integration by single neurons have traditionally emphasized empirical principles that describe nonlinear interactions between inputs from two sensory modalities. We previously proposed that many of these empirical principles could be explained by a divisive normalization mechanism operating in brain regions where multisensory integration occurs. This normalization model makes a critical diagnostic prediction: a non-preferred sensory input from one modality, which activates the neuron on its own, should suppress the response to a preferred input from another modality. We tested this prediction by recording from neurons in macaque area MSTd that integrate visual and vestibular cues regarding self-motion. We show that many MSTd neurons exhibit the diagnostic form of cross-modal suppression, whereas unisensory neurons in area MT do not. The normalization model also fits population responses better than a model based on subtractive inhibition. These findings provide strong support for a divisive normalization mechanism in multisensory integration. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Higher Fasting Plasma Glucose Levels, within the Normal Range, are Associated with Decreased Processing Speed in High Functioning Young Elderly.

    Science.gov (United States)

    Raizes, Meytal; Elkana, Odelia; Franko, Motty; Ravona Springer, Ramit; Segev, Shlomo; Beeri, Michal Schnaider

    2016-01-01

    We explored the association of plasma glucose levels within the normal range with processing speed in high functioning young elderly, free of type 2 diabetes mellitus (T2DM). A sample of 41 participants (mean age = 64.7, SD = 10; glucose 94.5 mg/dL, SD = 9.3), were examined with a computerized cognitive battery. Hierarchical linear regression analysis showed that higher plasma glucose levels, albeit within the normal range (levels may have an impact on cognitive function.

  18. Prognostic significance of hemoglobin level in patients with congestive heart failure and normal ejection fraction.

    Science.gov (United States)

    Varadarajan, Padmini; Gandhi, Siddharth; Sharma, Sanjay; Umakanthan, Branavan; Pai, Ramdas G

    2006-10-01

    Previous studies have shown low hemoglobin (Hb) to have an adverse effect on survival in patients with congestive heart failure (CHF) and reduced left ventricular (LV) ejection fraction (EF); but its effect on survival in patients with CHF and normal EF is not known. This study sought to determine whether low Hb has an effect on survival in patients with both CHF and normal EF. Detailed chart reviews were performed by medical residents on 2,246 patients (48% with normal EF) with a discharge diagnosis of CHF in a large tertiary care hospital from 1990 to 1999. The CHF diagnosis was validated using the Framingham criteria. Mortality data were obtained from the National Death Index. Survival analysis was performed using Kaplan-Meier and Cox regression models. By Kaplan-Meier analysis, low Hb (< 12 gm/dl) compared with normal hemoglobin was associated with a lower 5-year survival in patients with CHF and both normal (38 vs. 50%, p = 0.0008) and reduced (35 vs. 48%, p = 0.0009) EF. Using the Cox regression model, low Hb was an independent predictor of mortality after adjusting for age, gender, renal dysfunction, diabetes mellitus, hypertension, and EF in both groups of patients. Low Hb has an independent adverse effect on survival in patients with CHF and both normal and reduced EF in both groups of patients.

  19. Fasting and nonfasting lipid levels: influence of normal food intake on lipids, lipoproteins, apolipoproteins, and cardiovascular risk prediction

    DEFF Research Database (Denmark)

    Langsted, A.; Freiberg, J.J.; Nordestgaard, Børge

    2008-01-01

    BACKGROUND: Lipid profiles are usually measured after fasting. We tested the hypotheses that these levels change only minimally in response to normal food intake and that nonfasting levels predict cardiovascular events. METHODS AND RESULTS: We cross-sectionally studied 33 391 individuals 20 to 95...... to HDL cholesterol, and ratio of apolipoprotein B to apolipoprotein A1 did not change in response to normal food intake. The maximum changes after normal food and fluid intake from fasting levels were -0.2 mmol/L for total cholesterol, -0.2 mmol/L for low-density lipoprotein cholesterol, -0.1 mmol...... years of age from the Copenhagen General Population Study. We also studied 9319 individuals 20 to 93 years of age from the Copenhagen City Heart Study, 1166 of whom developed cardiovascular events during 14 years of follow-up. Compared with fasting levels, total cholesterol, low-density lipoprotein...

  20. A mass conserving level set method for detailed numerical simulation of liquid atomization

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Kun; Shao, Changxiao [State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027 (China); Yang, Yue [State Key Laboratory of Turbulence and Complex Systems, Peking University, Beijing 100871 (China); Fan, Jianren, E-mail: fanjr@zju.edu.cn [State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027 (China)

    2015-10-01

    An improved mass conserving level set method for detailed numerical simulations of liquid atomization is developed to address the issue of mass loss in the existing level set method. This method introduces a mass remedy procedure based on the local curvature at the interface, and in principle, can ensure the absolute mass conservation of the liquid phase in the computational domain. Three benchmark cases, including Zalesak's disk, a drop deforming in a vortex field, and the binary drop head-on collision, are simulated to validate the present method, and the excellent agreement with exact solutions or experimental results is achieved. It is shown that the present method is able to capture the complex interface with second-order accuracy and negligible additional computational cost. The present method is then applied to study more complex flows, such as a drop impacting on a liquid film and the swirling liquid sheet atomization, which again, demonstrates the advantages of mass conservation and the capability to represent the interface accurately.

  1. Separation of amino acids and antibiotics by narrow-bore and normal-bore high-performance liquid chromatography with pre-column derivatization.

    Science.gov (United States)

    Fiedler, H P; Plaga, A

    1987-01-16

    The selectivity, efficiency and lifetime of normal- and narrow-bore columns for high-performance liquid chromatography were investigated for the separation and quantification of amino acids and the amino acid-like antibiotics phosphinothricin and phosphinothricylalanylalanine in biological samples. These compounds were determined by an automated pre-column derivatization with o-phthalaldehyde-2-mercaptoethanol reagent and UV detection at 338 nm.

  2. Effects of synthetic TRH on plasma human prolactin levels in normal subjects and in patients with various endocrine disorders

    International Nuclear Information System (INIS)

    Ogawa, Norio; Miyoshi, Masanori; Suzuki, Shinya; Ofuji, Tadashi; Furuno, Katsushi

    1974-01-01

    HPRL was iodinated a modification of the enzymatic method using lactoperoxidase. By solid-phase RIA using antibody-coated disposable plastic microtiter trays, it was confirmed that the second peak consisted of the immunoreactive material that was used for RIA. For the measurement of plasma hPRL levels, the double antibody technique was used to separate bound from free labeled hormones. Basal plasma hPRL levels in normal subjects were less than 20 ng/ml. The mean basal hPRL levels were 10.2 +- 4.9 (Mean+-SD) ng/ml in 13 normal men and 9.6+-5.4 ng/ml in 8 normal women; no statistically significant sex difference was observed. When synthetic TRH was administered intravenously to a normal male subject, the maximum increase in plasma hPRL above the baseline level increased linearly as a function of the log of the TRH dose between 25 and 100 μg of TRH. Intravenous administration of 500 μg of TRH caused a significant increase in plasma hPRL in all of the 10 normal subjects tested. Plasma hPRL levels in 2 patients with Sheehan's syndrome and in a patient with operated-irradiated chromophobe adenoma tended to be low, and they showed no significant increase in plasma hPRL after TRH injection. Basal plasma hPRL levels in most of the patients with hypothalamopituitary tumor tended to be high. Plasma hPRL levels were normal in most patients with pituitary dwarfism. Plasma hPRL levels in 2 patients with hyperthyroidism tended to be low, and they showed no significant hPRL response to TRH, while patients with hypothyroidism showed normal or rather exaggerated hPRL response to TRH. Plasma hPRL levels were normal in most of the patients with Cushing's syndrome and plasma hPRL responses to TRH in these patients were normal. TRH-induced hPRL secretion tended to be impaired in patients receiving long-term and high doses of glucocorticoid. (auth.)

  3. Formation and filtration characteristics of solids generated in a high level liquid waste treatment process. Filtration characteristics of solids formed in simulated high level liquid waste

    International Nuclear Information System (INIS)

    Kondo, Y.; Kubota, M.

    1997-01-01

    The filtration characteristics of solids generated in a simulated high level liquid waste (HLLW) were experimentally examined, when the simulated HLLW was processed according to the ordinary way of actual HLLW treatment process. The filtration characteristics of solids depended on the particle size. The phosphomolybdic acid, which was very fine particle with about 0.1 μm diameter, made slurry a 'difficult-to-filter' slurry, if the phosphomolybdic acid content (wt%) to the whole solids in a slurry exceeded 50wt%. On the contrary, the zirconium compounds (zirconium molybdate and zirconium telluride) had positive effect on filtration characteristics because of their relatively large particle size of about 3 to 5 μm. When the zirconium compounds content was above 50 wt%, slurry became a 'easy-to-filter' slurry. A centrifugal sedimentation was discussed as a solid/liquid separation technique for very fine particles such as phosphomolybdic acid. The theoretical feed flow rate corresponded to 0.1 μm diameter particles was about 20 1/h at the centrifugal acceleration of about 8000 G. (author)

  4. A Novel Acoustic Liquid Level Determination Method for Coal Seam Gas Wells Based on Autocorrelation Analysis

    Directory of Open Access Journals (Sweden)

    Ximing Zhang

    2017-11-01

    Full Text Available In coal seam gas (CSG wells, water is periodically removed from the wellbore in order to keep the bottom-hole flowing pressure at low levels, facilitating the desorption of methane gas from the coal bed. In order to calculate gas flow rate and further optimize well performance, it is necessary to accurately monitor the liquid level in real-time. This paper presents a novel method based on autocorrelation function (ACF analysis for determining the liquid level in CSG wells under intense noise conditions. The method involves the calculation of the acoustic travel time in the annulus and processing the autocorrelation signal in order to extract the weak echo under high background noise. In contrast to previous works, the non-linear dependence of the acoustic velocity on temperature and pressure is taken into account. To locate the liquid level of a coal seam gas well the travel time is computed iteratively with the non-linear velocity model. Afterwards, the proposed method is validated using experimental laboratory investigations that have been developed for liquid level detection under two scenarios, representing the combination of low pressure, weak signal, and intense noise generated by gas flowing and leakage. By adopting an evaluation indicator called Crest Factor, the results have shown the superiority of the ACF-based method compared to Fourier filtering (FFT. In the two scenarios, the maximal measurement error from the proposed method was 0.34% and 0.50%, respectively. The latent periodic characteristic of the reflected signal can be extracted by the ACF-based method even when the noise is larger than 1.42 Pa, which is impossible for FFT-based de-noising. A case study focused on a specific CSG well is presented to illustrate the feasibility of the proposed approach, and also to demonstrate that signal processing with autocorrelation analysis can improve the sensitivity of the detection system.

  5. Physical activity levels of normal-weight and overweight girls and boys during primary school recess.

    Science.gov (United States)

    Stratton, Gareth; Ridgers, Nicola D; Fairclough, Stuart J; Richardson, David J

    2007-06-01

    This study aimed to compare moderate-to-vigorous physical activity (MVPA) and vigorous physical activity (VPA) in normal-weight and overweight boys and girls during school recess. Four hundred twenty children, age 6 to 10 years, were randomly selected from 25 schools in England. Three hundred seventy-seven children completed the study. BMI was calculated from height and weight measurements, and heart rate reserve thresholds of 50% and 75% reflected children's engagement in MVPA and VPA, respectively. There was a significant main effect for sex and a significant interaction between BMI category and sex for the percent of recess time spent in MVPA and VPA. Normal-weight girls were the least active group, compared with overweight boys and girls who were equally active. Fifty-one boys and 24 girls of normal weight achieved the 40% threshold; of these, 30 boys and 10 girls exceeded 50% of recess time in MVPA. Eighteen overweight boys and 22 overweight girls exceeded the 40% threshold, whereas 8 boys and 8 girls exceeded the 50% threshold. Overweight boys were significantly less active than their normal-weight male counterparts; this difference did not hold true for girls. Even though nearly double the number of normal-weight children achieved the 40% of MVPA during recess compared with overweight children, physical activity promotion in school playgrounds needs to be targeted not only at overweight but at other health parameters, as 40 overweight children met the 40% MVPA target proposed for recess.

  6. Functions and Requirements for Automated Liquid Level Gauge Instruments in Single-Shell and Double-Shell Tank Farms

    International Nuclear Information System (INIS)

    CARPENTER, K.E.

    1999-01-01

    This functions and requirements document defines the baseline requirements and criteria for the design, purchase, fabrication, construction, installation, and operation of automated liquid level gauge instruments in the Tank Farms. This document is intended to become the technical baseline for current and future installation, operation and maintenance of automated liquid level gauges in single-shell and double-shell tank farms

  7. [Gastric emptying of a solid-liquid meal in normal subjects: validity of the labeling (99mTc) of chicken liver by a multipuncture technic].

    Science.gov (United States)

    Hostein, J; Capony, P; Busquet, G; Bost, R; Fournet, J

    1985-04-01

    For gastric emptying studies of a solid-liquid meal by the scintigraphic method, a valid isotope labeling method for each phase of the meal must be obtained. The aim of this study was to validate a simple chicken liver labeling method in normal subjects by multipuncture technic with 99mtechnetium. Labeling according to Meyer's method was chosen as a reference. Simultaneously, a study of the quality of liquid phase labeling by 111indium was done. The labeling process quality for each phase of the meal was assessed: a) in vitro, after incubation of the meal with human gastric juice (n = 12); b) in vivo, after meal ingestion and sequential collection of gastric contents by aspiration (n = 4). Furthermore, in 8 healthy volunteers, gastric emptying curves of the solid and liquid phases of the meal were determined scintigraphically and compared. Our results showed: a) for the solid phase: a good specificity of the marker, which was assessed in vitro and in vivo, after liver labeling with multipuncture technique (89 p. 100 and 92 p. 100 after 180 min, respectively); b) for the liquid phase: a good specificity of the marker in vitro and a poor specificity in vivo (82 p. 100 and 27 p. 100 after 180 min, respectively); c) similar half-gastric emptying times and cumulative percentages for the solid and liquid phases with both liver labeling methods. In conclusion, the multipuncture technique for chicken liver labeling may be used for gastric emptying studies in humans.

  8. The incorporation of low and medium level radioactive wastes (solids and liquids) in cement

    International Nuclear Information System (INIS)

    Palmer, J.D.; Smith, D.L.G.

    1986-01-01

    The use of cement has been investigated for the immobilization of liquid and solid low and medium level radioactive waste. 220 litre mixing trials have demonstrated that the high temperatures generated during the setting of ordinary Portland cement/simulant waste mixes can be significantly reduced by the use of a blend of ground granulated blast furnace slag and ordinary Portland cement. Laboratory and 220 litre trials using simulant wastes showed that the blended cement gave an improvement in properties of the cemented waste product, e.g. stability and reduction in leach rates compared with ordinary Portland cement formulations. A range of 220 litre scale mixing systems for the incorporation of liquid and solid wastes in cement was investigated. The work has confirmed that cement-based processes can be used for the immobilization of most types of low and medium level waste

  9. Levels of endogenous regulatory factors in liquidators of consequences of the Chernobyl accident

    International Nuclear Information System (INIS)

    Liasko, L.I.; Souchkevitch, G.N.; Tsyb, A.F.

    1997-01-01

    Dynamics of endogenous regulatory factor levels was studied in liquidators of consequences of the Chernobyl accident (mean age - 42 years). Irradiation dose for 90% of examined individuals was within 100 mSv range. We observed a decreased level of synthesis of intracellular processes regulators (cAMP, cGMP) and biased ratio of arachidonic acid metabolites (TxB2, 6-Keto-PGF1α) in persons worked in the zone of accident at different time during the period of 1986-1988. The parameters measured were preserved even 4 years later and the changes apparently did not depend on the individual's age and work conditions. However they were most pronounced in liquidators of 1986 and in those who stayed in the Chernobyl accident zone for a long time. There was no evident connection between the dose and extent of the parameter alterations. (author)

  10. Development of a partitioning method for the management of high-level liquid waste

    International Nuclear Information System (INIS)

    Kubota, M.; Dojiri, S.; Yamaguchi, I.; Morita, Y.; Yamagishi, I.; Kobayashi, T.; Tani, S.

    1989-01-01

    Fundamental studies especially focused on the separation of neptunium and technetium have been carried out to construct the advanced partitioning process of fractioning elements in a high-level liquid waste into four groups: transuranium elements, technetium-noble metals, strontium-cesium, and other elements. For the separation of neptunium by solvent extraction, DIDPA proved excellent for extracting Np(V), and its extraction rate was accelerated by hydrogen peroxide. Np(V) was found to be also separated quantitatively as precipitate with oxalic acid. For the separation of technetium, the denitration with formic acid was effective in precipitating it along with noble metals, and the adsorption with activated carbon was also effective for quantitative separation. Through these fundamental studies, the advanced partitioning process is presented as the candidate to be examined with an actual high-level liquid waste

  11. Formation and filtration characteristics of solids generated in a high level liquid waste treatment process. Solids formation behavior from simulated high level liquid waste

    International Nuclear Information System (INIS)

    Kondo, Y.; Kubota, M.

    1997-01-01

    The solids formation behavior in a simulated high level liquid waste (HLLW) was experimentally examined, when the simulated HLLW was treated in the ordinary way of actual HLLW treatment process. Solids formation conditions and mechanism were closely discussed. The solids formation during a concentration step can be explained by considering the formation of zirconium phosphate, phosphomolybdic acid and precipitation of strontium and barium nitrates and their solubilities. For the solids formation during the denitration step, at least four courses were observed; formation of an undissolved material by a chemical reaction with each other of solute elements (zirconium, molybdenum, tellurium) precipitation by reduction (platinum group metals) formation of hydroxide or carbonate compounds (chromium, neodymium, iron, nickel, strontium, barium) and a physical adsorption to stable solid such as zirconium molybdate (nickel, strontium, barium). (author)

  12. Basic conditions for radioimmunoassay of erythropoietin, and plasma levels of erythropoietin in normal subjects and anemic patients

    Energy Technology Data Exchange (ETDEWEB)

    Mizoguchi, Hideaki; Ohta, Kazuo; Suzuki, Toshiaki; Murakami, Akihiko; Ueda, Masatsugu; Sasaki, Ryuzou; Chiba, Hideo

    1987-02-01

    We have developed a specific and sensitive radioimmunoassay for erythropoietin. The sensitivity of our assay is 0.5 mU or 5 mU/ml and is sufficient to detect normal plasma erythropoietin levels. The mean plasma erythropoietin titer of normal Japanese with our radioimmunoassay was found to be 21.9 +- 12.0 mU/ml (n = 199). The validity of the method was further confirmed by the observations that the plasma erythropoietin titers were inversely related to hemoglobin levels in patients with nonuremic anemias, lower in uremic patients than in patients with nonuremic anemias with similar hemoglobin levels, markedly elevated in patients with aplastic anemia and pure red cell aplasia, and in a low normal range in patients with polycythemia vera.

  13. Measurement of liquid level in a natural circulation circuit using an ultrasonic technique

    International Nuclear Information System (INIS)

    Barbosa, Amanda Cardozo; Su, Jian

    2017-01-01

    The measurement by an ultrasonic technique of the water level in the expansion tank of the Natural Circulation Circuit (NCC) of the Experimental Thermo-Hydraulic Laboratory of the Institute of Nuclear Engineering is presented. In the single-phase NCC operation the water level in the expansion tank is stable. However, during the two-phase operation, oscillations occur in the water level due to temperature and vacuum fraction variations. Thus, the development of a technique that allows the measurement of these oscillations, will allow an estimation of the variation of the vacuum fraction of the circuit over time. The experimental set - up was performed on a test bench, using an ultrasonic transducer. The ultrasonic technique used is pulse-echo, in which the same transducer is the transmitter and receiver of the signal. The transducer-shoe assembly is part of an ultrasonic system consisting of an ultrasonic signal generating plate, transducers and a computer (PC) with a program in LabView to control the system. The program is able to calculate the transit time that the ultrasonic signals take to cross the tank base wall, the layer (level) of liquid and return to the transducer. Knowing the speed of the ultrasound in the wall and in the liquid it is possible to calculate the thickness of the wall and the height of the liquid. Measurements were made by filling the tank with a known volume of water and under varying temperature conditions, from room temperature to 90 deg C. The liquid heights are determined and the volume of water calculated by measuring the temperature with a digital thermometer. The volumes measured were highly accurate when compared to the known volumes

  14. Removal of Aerosol Particles Generated from Vitrification Process for High-Level Liquid Wastes

    OpenAIRE

    加藤 功

    1990-01-01

    The vitrification technology has been developed for the high-level liquid waste (HLLW) from reprocessing nuclear spent fuel in PNC. The removal performance of the aerosol particles generated from the melting process was studied in a nonradioactive full-scale mock-up test facility (MTF). The off-gas treatment system consists of submerged bed scrubber (SBS), venturi scrubber, NOx absorber, high efficiency mist eliminater (HEME). Deoomtamination factors (DFs) were derived from the mass ratio of ...

  15. Development of Concentration and Calcination Technology For High Level Liquid Waste

    International Nuclear Information System (INIS)

    Pande, D.P.

    2006-01-01

    The concentrated medium and high-level liquid radio chemicals effluents contain nitric acid, water along with the dissolved chemicals including the nitrates of the radio nuclides. High level liquid waste contain mainly nitrates of cesium, strontium, cerium, zirconium, chromium, barium, calcium, cobalt, copper, pickle, iron etc. and other fission products. This concentrated solution requires further evaporation, dehydration, drying and decomposition in temperature range of 150 to 700 deg. C. The addition of the calcined solids in vitrification pot, instead of liquid feed, helps to avoid low temperature zone because the vaporization of the liquid and decomposition of nitrates do not take place inside the melter. In our work Differential and thermo gravimetric studies has been carried out in the various stages of thermal treatment including drying, dehydration and conversion to oxide forms. Experimental studies were done to characterize the chemicals present in high-level radioactive waste. A Rotary Ball Kiln Calciner was used for development of the process because this is amenable for continuous operation and moderately good heat transfer can be achieved inside the kiln. This also has minimum secondary waste and off gases generation. The Rotary Ball Kiln Calciner Demonstration facility system was designed and installed for the demonstration of calcination process. The Rotary Ball Kiln Calciner is a slowly rotating slightly inclined horizontal tube that is externally heated by means of electric resistance heating. The liquid feed is sprayed onto the moving bed of metal balls in a slowly rotating calciner by a peristaltic type-metering pump. The vaporization of the liquid occurs in the pre-calcination zone due to counter current flow of hot gases. The dehydration and denitration of the solids occurs in the calcination zone, which is externally heated by electrical furnace. The calcined powder is cooled in the post calcination portion. It has been demonstrated that the

  16. Normal cholesterol levels with lovastatin (Mevinolin) therapy in a child with homozygous familial hypercholesterolemia following liver transplantation

    International Nuclear Information System (INIS)

    East, C.; Grundy, S.M.; Bilheimer, D.W.

    1986-01-01

    Patients with homozygous familial hypercholesterolemia produce no normal low-density lipoprotein (LDL) receptors, and as a result, LDL accumulates in plasma, causing severe premature atherosclerosis. Two years ago, liver transplantation was performed in a child with homozygous familial hypercholesterolemia, restoring LDL receptor activity to about 60% of normal and reducing the LDL cholesterol level by 81%. However, the patient's lipoprotein levels remained significantly elevated for her age and sex. Treatment with lovastatin (mevinolin) one year after transplantation produced a marked improvement in the patient's lipoprotein profile. The total and LDL cholesterol levels fell 40% and 49%, respectively, to values within the normal range. The level of very low-density lipoprotein cholesterol fell 41%, and the level of total triglycerides declined 28%. While lovastatin therapy decreased the production rate of LDL by 35%, it did not affect the LDL fractional clearance rate. Thus, the combination of liver transplantation and lovastatin restored total and LDL cholesterol levels to normal in this patient with homozygous familial hypercholesterolemia

  17. Treatment of low level radioactive liquid waste containing appreciable concentration of TBP degraded products.

    Science.gov (United States)

    Valsala, T P; Sonavane, M S; Kore, S G; Sonar, N L; De, Vaishali; Raghavendra, Y; Chattopadyaya, S; Dani, U; Kulkarni, Y; Changrani, R D

    2011-11-30

    The acidic and alkaline low level radioactive liquid waste (LLW) generated during the concentration of high level radioactive liquid waste (HLW) prior to vitrification and ion exchange treatment of intermediate level radioactive liquid waste (ILW), respectively are decontaminated by chemical co-precipitation before discharge to the environment. LLW stream generated from the ion exchange treatment of ILW contained high concentrations of carbonates, tributyl phosphate (TBP) degraded products and problematic radio nuclides like (106)Ru and (99)Tc. Presence of TBP degraded products was interfering with the co-precipitation process. In view of this a modified chemical treatment scheme was formulated for the treatment of this waste stream. By mixing the acidic LLW and alkaline LLW, the carbonates in the alkaline LLW were destroyed and the TBP degraded products got separated as a layer at the top of the vessel. By making use of the modified co-precipitation process the effluent stream (1-2 μCi/L) became dischargeable to the environment after appropriate dilution. Based on the lab scale studies about 250 m(3) of LLW was treated in the plant. The higher activity of the TBP degraded products separated was due to short lived (90)Y isotope. The cement waste product prepared using the TBP degraded product was having good chemical durability and compressive strength. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. The storage of liquid high level waste at BNFL, Sellafield. Addendum to February 2000 report

    International Nuclear Information System (INIS)

    2001-08-01

    On 18 February 2000 the Health and Safety Executive (HSE) published a report on the work of its Nuclear Installations Inspectorate (NIl) in regulating the storage of liquid high level waste at the BNFL Sellafield site. Within the report NIl gave two undertakings. One was to publish an addendum around 1 year later covering its assessment of the new safety case for the storage plant and the second was to publish a further addendum when progress had been made with options studies for reducing the stocks of liquid high level waste (HLW), also referred to as highly active liquor (HAL), to a buffer level. A progress report was published in February 2001 which included a summary of the assessment of the new safety case and NIl's regulatory action to enforce liquid HLW stock reductions. This addendum provides a more detailed update on the position reached based on consideration of BNFL's responses to the recommendations from the February 2000 HLW report since its publication. It embodies the two addenda referred to above integrated into a single document for publication

  19. Continuous liquid level detection based on two parallel plastic optical fibers in a helical structure

    Science.gov (United States)

    Zhang, Yingzi; Hou, Yulong; Zhang, Yanjun; Hu, Yanjun; Zhang, Liang; Gao, Xiaolong; Zhang, Huixin; Liu, Wenyi

    2018-02-01

    A simple and low-cost continuous liquid-level sensor based on two parallel plastic optical fibers (POFs) in a helical structure is presented. The change in the liquid level is determined by measuring the side-coupling power in the passive fiber. The side-coupling ratio is increased by just filling the gap between the two POFs with ultraviolet-curable optical cement, making the proposed sensor competitive. The experimental results show that the side-coupling power declines as the liquid level rises. The sensitivity and the measurement range are flexible and affected by the geometric parameters of the helical structure. A higher sensitivity of 0.0208 μW/mm is acquired for a smaller curvature radius of 5 mm, and the measurement range can be expanded to 120 mm by enlarging the screw pitch to 40 mm. In addition, the reversibility and temperature dependence are studied. The proposed sensor is a cost-effective solution offering the advantages of a simple fabrication process, good reversibility, and compensable temperature dependence.

  20. Immobilization of low and intermediate level radioactive liquid wastes using some industrial by-product materials

    International Nuclear Information System (INIS)

    Sami, N.M.; EI-Dessouky, M.I.; Abou EI-Nour, F.H.; Abdel-Khalik, M.

    2006-01-01

    Immobilization of low and intermediate level.radioactive liquid wastes in different matrices: ordinary Portland cement and cement mixed with some industrial byproduct: by-pass kiln cement dust, blast furnace slag and ceramic sludge was studied. The effect of these industrial by-product materials on the compressive strength, water immersion, radiation effect and teachability were investigated. The obtained results showed that, these industrial by-product improve the cement pastes where they increase the compressive strength, decrease the leaching rate for radioactive cesium-137 and cobalt-60 ions through the solidified waste forms and increase resistance for y-radiation. It is found that, solidified waste forms of intermediate level liquid waste (ILLW) had high compressive strength values more than those obtained from low level liquid waste (LLLW). The compressive strength increased after immersion in different leachant for one and three months for samples with LLLW higher than those obtained for ILLW. The cumulative fractions released of cesium-137 and cobalt-60 of solidified waste forms of LLLW was lower than those obtained for ILLW

  1. Vasopressin and oxytocin levels during normal pregnancy: effects of chronic dietary sodium restriction

    NARCIS (Netherlands)

    van der Post, J. A.; van Buul, B. J.; Hart, A. A.; van Heerikhuize, J. J.; Pesman, G.; Legros, J. J.; Steegers, E. A.; Swaab, D. F.; Boer, K.

    1997-01-01

    Neurohypophysial hormones are thought to be involved in alterations in fluid balance during pregnancy and delivery. In the course of normal pregnancy intravascular volume is increased whereas sodium restriction is thought to reduce plasma volume and cardiac output. In the present study, we measured

  2. Action plan for response to abnormal conditions in Hanford high level radioactive liquid waste storage tanks containing flammable gases

    International Nuclear Information System (INIS)

    Sherwood, D.J.

    1994-03-01

    Radioactive liquid waste tends to produce hydrogen as a result of the interaction of gamma radiation and water. In tanks containing organic chelating agents, additional hydrogen gas as well as nitrous oxide and ammonia can be produced by thermal and radiolytic decomposition of these organics. Several high-level radioactive liquid waste storage tanks, located underground at the Hanford Site, contain waste that retains the gases produced in them until large quantities are released rapidly to the tank vapor space. Tanks filled to near capacity have relatively little vapor space; therefore, if the waste suddenly releases a large amount of hydrogen and nitrous oxide, a flammable gas mixture may result. The most notable waste tank with a flammable gas problem is tank 241-SY-101. Waste in this tank has occasionally released enough flammable gas to burn if an ignition source had been present inside of the tank. Several other waste tanks exhibit similar behavior to a lesser magnitude. Administrative controls have been developed to assure that these Flammable Gas Watch List tanks are safely maintained. Responses have also been developed for off-normal conditions which might develop in these tanks. In addition, scientific and engineering studies are underway to further understand and mitigate the behavior of the Flammable Gas Watch List tanks

  3. Thyroid storm with multiple organ failure, disseminated intravascular coagulation, and stroke with a normal serum FT3 level.

    Science.gov (United States)

    Harada, Yuko; Akiyama, Hisanao; Yoshimoto, Tatsuji; Urao, Yasuko; Ryuzaki, Munekazu; Handa, Michiko

    2012-01-01

    Thyroid storm is a rare disorder with a sudden onset, rapid progression and high mortality. We experienced a case of thyroid storm which had a devastating course, including multiple organ failure (MOF), severe hypoglycemia, disseminated intravascular coagulation (DIC), and stroke. It was difficult to make a diagnosis of thyroid storm in the present patient, because she did not have a history of thyroid disease and her serum FT3 level was normal. Clinicians should be aware that thyroid storm can occur even when there is an almost normal level of thyroid hormones, and that intensive anticoagulation is required for patients with atrial fibrillation to prevent stroke after thyroid storm.

  4. Long-Period Fiber Grating Sensors for the Measurement of Liquid Level and Fluid-Flow Velocity

    Science.gov (United States)

    Wang, Jian-Neng; Luo, Ching-Ying

    2012-01-01

    This paper presents the development and assessment of two types of Long Period Fiber Grating (LPFG)-based sensors including a mobile liquid level sensor and a reflective sensor for the measurement of liquid level and fluid-flow velocity. Shewhart control charts were used to assess the liquid level sensing capacity and reliability of the mobile CO2-laser engraved LPFG sensor. There were ten groups of different liquid level experiment and each group underwent ten repeated wavelength shift measurements. The results showed that all measurands were within the control limits; thus, this mobile sensor was reliable and exhibited at least 100-cm liquid level measurement capacity. In addition, a reflective sensor consisting of five LPFGs in series with a reflective end has been developed to evaluate the liquid level and fluid-flow velocity. These five LPFGs were fabricated by the electrical arc discharge method and the reflective end was coated with silver by Tollen's test. After each liquid level experiment was performed five times, the average values of the resonance wavelength shifts for LPFG Nos. 1–5 were in the range of 1.35–9.14 nm. The experimental findings showed that the reflective sensor could be used to automatically monitor five fixed liquid levels. This reflective sensor also exhibited at least 100-cm liquid level measurement capacity. The mechanism of the fluid-flow velocity sensor was based on analyzing the relationship among the optical power, time, and the LPFG's length. There were two types of fluid-flow velocity measurements: inflow and drainage processes. The differences between the LPFG-based fluid-flow velocities and the measured average fluid-flow velocities were found in the range of 8.7–12.6%. For the first time to our knowledge, we have demonstrated the feasibility of liquid level and fluid-flow velocity sensing with a reflective LPFG-based sensor without modifying LPFGs or coating chemical compounds. PMID:22666046

  5. Long-period fiber grating sensors for the measurement of liquid level and fluid-flow velocity.

    Science.gov (United States)

    Wang, Jian-Neng; Luo, Ching-Ying

    2012-01-01

    This paper presents the development and assessment of two types of Long Period Fiber Grating (LPFG)-based sensors including a mobile liquid level sensor and a reflective sensor for the measurement of liquid level and fluid-flow velocity. Shewhart control charts were used to assess the liquid level sensing capacity and reliability of the mobile CO(2)-laser engraved LPFG sensor. There were ten groups of different liquid level experiment and each group underwent ten repeated wavelength shift measurements. The results showed that all measurands were within the control limits; thus, this mobile sensor was reliable and exhibited at least 100-cm liquid level measurement capacity. In addition, a reflective sensor consisting of five LPFGs in series with a reflective end has been developed to evaluate the liquid level and fluid-flow velocity. These five LPFGs were fabricated by the electrical arc discharge method and the reflective end was coated with silver by Tollen's test. After each liquid level experiment was performed five times, the average values of the resonance wavelength shifts for LPFG Nos. 1-5 were in the range of 1.35-9.14 nm. The experimental findings showed that the reflective sensor could be used to automatically monitor five fixed liquid levels. This reflective sensor also exhibited at least 100-cm liquid level measurement capacity. The mechanism of the fluid-flow velocity sensor was based on analyzing the relationship among the optical power, time, and the LPFG's length. There were two types of fluid-flow velocity measurements: inflow and drainage processes. The differences between the LPFG-based fluid-flow velocities and the measured average fluid-flow velocities were found in the range of 8.7-12.6%. For the first time to our knowledge, we have demonstrated the feasibility of liquid level and fluid-flow velocity sensing with a reflective LPFG-based sensor without modifying LPFGs or coating chemical compounds.

  6. High Normal Uric Acid Levels Are Associated with an Increased Risk of Diabetes in Lean, Normoglycemic Healthy Women.

    Science.gov (United States)

    Shani, Michal; Vinker, Shlomo; Dinour, Dganit; Leiba, Merav; Twig, Gilad; Holtzman, Eliezer J; Leiba, Adi

    2016-10-01

    The risk associated with serum uric acid (SUA) levels within the normal range is unknown, especially among lean and apparently healthy adults. Evaluating whether high-normal SUA levels, 6.8 mg/dL and below, are associated with an increased diabetes risk, compared with low-normal SUA. This was a cohort study with 10 years of followup involving all clinics of the largest nationally distributed Health Maintenance Organization in Israel. Participants included 469,947 examinees, 40-70 years old at baseline, who had their SUA measured during 2002. We excluded examinees who had hyperuricemia (SUA > 6.8 mg/dL), impaired fasting glucose, overweight or obesity and chronic cardiovascular or renal disorders. The final cohort was composed of 30 302 participants. Participants were followed up to a new diagnosis of diabetes during the study period. Odds ratio of developing diabetes among participants with high-normal baseline SUA were compared with low-normal (2 ≤ uric acid lean women when compared with those with low-normal values.

  7. Cerebrospinal liquid nerve growth factor levels in patients with Alzheimer's disease

    International Nuclear Information System (INIS)

    Mashayakhi, F.; Salehi, Z.

    2006-01-01

    Alzheimer's disease (AD) is the most common cause of dementia in the Western countries and in Japan. Numerous blood and cerebrospinal fluid (CSF) tests based on the disease pathology have been proposed for early detection of AD. By comparing the CSF proteome of AD patients and controls it might be possible to identify proteins that play a role in the disease process and thus study the pathogenesis of AD. Samples of CSF from normal (n=20) and AD patients (n=20) were collected by lumbar puncture. The total concentration of proteins in the CSF of normal subjects and AD patients was determined by Bio-Rad protein assay based on the Bradford dye binding procedures. The presence and level of NGF in the CSF of normal and AD patients was measured by enzyme linked immunosorbant assay (ELISA), SDS-PAGE and western blot. The total protein concentration of all samples was within the normal range (0.10-0.44). a western blot analysis using anti-NGF antibody showed the presence of NGF in human CSF. By ELISA the level of NGF in the CSF of AD patients was higher than in the CSF of normal subjects (81.5+-15.03 pg/mt, P,0.0001). We suggest that the NGF level in the CSF may provide additional information in the differential diagnosis of Alzheimer disease. We also conclude that NGF could be significantly involved in the pathophysiology of AD. (author)

  8. Level trend analysis summary report for Oak Ridge National Laboratory inactive liquid low-level waste tanks

    International Nuclear Information System (INIS)

    1994-09-01

    Oak Ridge National Laboratory facilities have produced liquid low-level waste (LLLW) that is radioactive and/or hazardous. Storage tanks have been used to collect and store these wastes. Most of the collection system, including the tanks, is located below the ground surface. Many of the systems have been removed from service (i.e., are not inactive) but contain residual amounts of waste liquid and sludges. A plan of action has been developed by DOE to ensure that environmental impacts from the waste remaining in the inactive tanks system are minimized. The Federal Facility Agreement (FFA) does not require any type of testing or monitoring for the inactive LLLW tanks that are removed from service but does require waste characterization of tanks contents, risk characterization of tanks removed from service, and remediation of the inactive tanks and their contents. This report is form information only and is not required by the FFA. It includes a description of the methodology and results of level trend analyses for the Category D tanks listed in the FFA that currently belong to the Environmental Restoration Program

  9. Cutoff Values of Serum Carcinoembryonic Antigen (CEA) in Normal Korean Adults and Factors Influencing Serum CEA Level

    International Nuclear Information System (INIS)

    Kim, Jong Soon; Kim, Sun Wook; Chung, June Key; Lee, Dong Soo

    1994-01-01

    Carcinoembryonic Antigen is one of most frequently checked tumor markers in cancer management. We performed statistical analysis with serum CEA data of 2626 persons who received regular health examination and were thought to be free of active disease to determine the cutoff values of serum CEA level in normal Korean adults and to study the factors influencing serum CEA levels in normal subjects. 1) The cutoff values of serum CEA in normal Korean adults in general were 9.28 ng/ml for men, 5.90 ng/ml for women. 2) Serum CEA level was influenced by age, present smoking history, sex, and abnormal findings in chest X ray. 3) Serum CEA level had no correlation with the history of amount of alcohol consumption or obesity. 4) Cutoff values of serum CEA in normal Korean adults were tabulated according to age, sex, and smoking history. Serum CEA level was influenced by age, sex, present smoking history and abnormal findings in chest X ray and cutoff values of serum CEA were tabulated according to age, sex, and smoking history.

  10. Design and construction of the low-level liquid waste treatment system

    International Nuclear Information System (INIS)

    Baker, M.N.; Mateer, W.E.; Metzler, G.H.; Reeves, S.R.; Rickettson, D.J.

    1989-03-01

    This report describes the design and construction of the Low-Level Liquid Waste Treatment System (LWTS). The LWTS is part of a system that will prepare High-Level Radioactive Waste for solidification in glass. This preparation includes removal of water and salts from the stored waste. The topics addressed are: the design objective to reuse the Process Building to contain LWTS, the special considerations that arise when building a new system inside a decontaminated facility, interface to existing plant systems, phased construction, and construction testing. 8 refs., 24 figs

  11. Vapour–Liquid Equilibria in the Polymer + Solvent System Containing Lower Concentrations of Solute at Normal or Reduced Pressures

    Czech Academy of Sciences Publication Activity Database

    Pavlíček, Jan; Bogdanić, Grozdana; Wichterle, Ivan

    2013-01-01

    Roč. 358, 25 NOV (2013), s. 301-303 ISSN 0378-3812 Institutional support: RVO:67985858 Keywords : vapour–liquid equilibrium * experimental data * polymer-solvent system Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.241, year: 2013

  12. Pathogenesis of fever: effects of various endogenous pyrogens upon the level of circulating granulocytes in normal rabbits.

    Science.gov (United States)

    KING, M K

    1960-11-01

    The endogenous pyrogen in the serum or plasma of rabbits 2 hours after the intravenous injection of typhoid vaccine had a marked effect on the circulating leucocytes of normal rabbits. Immediately following intravenous injection there was a brief, but marked, granulocytopenia which was quickly followed by a granulocytosis. Under the same circumstances pooled heterologous serum or plasma from normal rabbits produced no fever or significant change in the level of circulating leucocytes. The cell-free fluid of sterile peritoneal exudates produced a marked leucocytosis without a preceding leucopenia when injected intravenously into normal rabbits. When comparably pyrogenic doses of typhoid vaccine were injected in the same manner no significant change in the level of circulating leucocytes occurred. The relevance of these findings to the pathogenesis of fever is discussed.

  13. Actinide partitioning from high level liquid waste using the Diamex process

    International Nuclear Information System (INIS)

    Madic, C.; Blanc, P.; Condamines, N.; Baron, P.; Berthon, L.; Nicol, C.; Pozo, C.; Lecomte, M.; Philippe, M.; Masson, M.; Hequet, C.

    1994-01-01

    The removal of long-lived radionuclides, which belong to the so-called minor actinides elements, neptunium, americium and curium, from the high level nuclear wastes separated during the reprocessing of the irradiated nuclear fuels in order to transmute them into short-lived nuclides, can substantially decrease the potential hazards associated with the management of these nuclear wastes. In order to separate minor actinides from high-level liquid wastes (HLLW), a liquid-liquid extraction process was considered, based on the use of diamide molecules, which display the property of being totally burnable, thus they do not generate secondary solid wastes. The main extracting properties of dimethyldibutyltetradecylmalonamide (DMDBTDMA), the diamide selected for the development of the DIAMEX process, are briefly described in this paper. Hot tests of the DIAMEX process (using DMDBTDMA) related to the treatment of an mixed oxide fuels (MOX) type HLLW, were successfully performed. The minor actinide decontamination factors of the HLLW obtained were encouraging. The main results of these tests are presented and discussed in this paper. (authors). 9 refs., 2 figs., 7 tabs

  14. Intensity liquid level sensor based on multimode interference and fiber Bragg grating

    International Nuclear Information System (INIS)

    Oliveira, Ricardo; Aristilde, Stenio; Osório, Jonas H; Cordeiro, Cristiano M B; Franco, Marcos A R; Bilro, Lúcia; Nogueira, Rogério N

    2016-01-01

    In this paper an intensity liquid level sensor based on a single-mode—no-core—single-mode (SMS) fiber structure together with a Bragg grating inscribed in the later single mode fiber is proposed. As the no-core fiber is sensitive to the external refractive index, the SMS spectral response will be shifted related to the length of no-core fiber that is immersed in a liquid. By positioning the FBG central wavelength at the spectral region of the SMS edge filter, it is possible to measure the liquid level using the reflected FBG peak power through an intensity-based approach. The sensor is also self-referenced using the peak power of another FBG that is placed before and far from the sensing part. The temperature error analysis was also studied revealing that the sensor can operate in environments where the temperature changes are minimal. The possibility to use a second setup that makes the whole device temperature insensitive is also discussed. (paper)

  15. Solidification of intermediate level liquid waste - ILLW, CEMEX waste form qualification

    International Nuclear Information System (INIS)

    D'Andrea, V.; Guerra, M.; Pancotti, F.; Maio, V.

    2015-01-01

    In the Sogin EUREX Facility about 125 m 3 of intermediate level radioactive waste and about 113 m 3 of low level radioactive waste, produced during the re-processing of MTR and CANDU fuel, are stored. Solidification of these wastes is planned in order to fulfill the specific requirements established by the Safety Authority, taking into account the criteria set up in a Technical Guide on the issue of radioactive waste management. The design of a cementation plant (CEMEX) of all liquid radioactive wastes is currently ongoing. The process requires that the liquid waste is neutralized with NaOH (NaOH 19 M) and metered into 440 liter drum together with the cement, while the mixture is stirred by a lost paddle ('in drum mixing process'). The qualification of the Waste Form consists of all the activities demonstrating that the final cemented product has the minimum requirements (mechanical, chemical and physical characteristics) compliant with all the subsequent management phases: long-term interim storage, transport and long-term disposal of the waste. All tests performed to qualify the conditioning process for immobilizing first extraction cycle (MTR and CANDU) and second extraction cycle liquid wastes, gave results in compliance with the minimum requirements established for disposal

  16. Comparison of blood lead levels of mothers and cord blood in intrauterine growth retarded neonates and normal term neonates

    International Nuclear Information System (INIS)

    Iranpour, R.; Besharati, Amir A.; Nasseri, F.; Hashemipour, M.; Kelishadi, R.; Balali-Mood, M.

    2007-01-01

    Objective was to compare the blood lead levels of mothers and cord blood in intrauterine growth retarded (IUGR) neonates and normal term neonates. From April 2005, we carried out a cross-sectional, prospective study in Isfahan University of Medical Sciences, Isfahan, Iran. Blood lead levels were measured in the umbilical cord and maternal venous blood samples in the 32 mother-infant pairs with IUGR full term neonates and 34 mother-infant pairs with normal full term neonates. Blood-lead levels were analyzed by atomic absorption spectrometry. The mean lead concentration in neonates of IUGR and normal groups was not significantly different (107.47+- 16.75 versus 113.08+-19.08 ug/L, p=0.2). The mean lead concentration in mothers of IUGR group was lower than normal groups, but this difference was not significant (124.56+-19.71 versus 135.26+-26.91 ug/L, p=0.07). Maternal lead levels were strongly related with related with cord blood in both IUGR and normal groups (r=0.8, p 100ug/L by the centers for disease control; however, this was not statistically different between the groups. Our results indicate that the mean lead level was not higher in IUGR neonates, and the whole blood lead was not related to the birth weight. In addition, maternal and cord blood lead levels were strongly correlated, and there were remarkable lead burdens on both the mothers and their neonates in this industrial area. (author)

  17. Melton Valley liquid low-level radioactive waste storage tanks evaluation

    International Nuclear Information System (INIS)

    1995-06-01

    The Melton Valley Liquid Low-Level Radioactive Waste Storage Tanks (MVSTs) store the evaporator concentrates from the Liquid Low-Level Radioactive Waste (LLLW) System at the Oak Ridge National Laboratory (ORNL). The eight stainless steel tanks contain approximately 375,000 gallons of liquid and sludge waste. These are some of the newer, better-designed tanks in the LLLW System. They have been evaluated and found by the US Environmental Protection Agency (EPA) and the Tennessee Department of Environment and Conservation to comply with all Federal Facility Agreement requirements for double containment. The operations and maintenance aspects of the tanks were also reviewed by the Defense Nuclear Facilities Safety Board (DNFSB) in September 1994. This document also contains an assessment of the risk to the public and ORNL workers from a leak in one of the MVSTs. Two primary scenarios were investigated: (1) exposure of the public to radiation from drinking Clinch River water contaminated by leaked LLLW, and (2) exposure of on-site workers to radiation by inhaling air contaminated by leaked LLLW. The estimated frequency of a leak from one of the MVSTs is about 8 x 10 -4 events per year, or about once in 1200 years (with a 95% confidence level). If a leak were to occur, the dose to a worker from inhalation would be about 2.3 x 10 -1 mrem (with a 95% confidence level). The dose to a member of the public through the drinking water pathway is estimated to be about 7 x 10 -1 mrem (with a 95% confidence level). By comparison with EPA Safe Drinking Water regulations, the allowable lifetime radiation dose is about 300 mrem. Thus, a postulated LLLW leak from the MVSTs would not add appreciably to an individual's lifetime radiation dose

  18. Lipoxin A4 stimulates calcium-activated chloride currents and increases airway surface liquid height in normal and cystic fibrosis airway epithelia.

    LENUS (Irish Health Repository)

    2012-01-01

    Cystic Fibrosis (CF) is a genetic disease characterised by a deficit in epithelial Cl(-) secretion which in the lung leads to airway dehydration and a reduced Airway Surface Liquid (ASL) height. The endogenous lipoxin LXA(4) is a member of the newly identified eicosanoids playing a key role in ending the inflammatory process. Levels of LXA(4) are reported to be decreased in the airways of patients with CF. We have previously shown that in normal human bronchial epithelial cells, LXA(4) produced a rapid and transient increase in intracellular Ca(2+). We have investigated, the effect of LXA(4) on Cl(-) secretion and the functional consequences on ASL generation in bronchial epithelial cells obtained from CF and non-CF patient biopsies and in bronchial epithelial cell lines. We found that LXA(4) stimulated a rapid intracellular Ca(2+) increase in all of the different CF bronchial epithelial cells tested. In non-CF and CF bronchial epithelia, LXA(4) stimulated whole-cell Cl(-) currents which were inhibited by NPPB (calcium-activated Cl(-) channel inhibitor), BAPTA-AM (chelator of intracellular Ca(2+)) but not by CFTRinh-172 (CFTR inhibitor). We found, using confocal imaging, that LXA(4) increased the ASL height in non-CF and in CF airway bronchial epithelia. The LXA(4) effect on ASL height was sensitive to bumetanide, an inhibitor of transepithelial Cl(-) secretion. The LXA(4) stimulation of intracellular Ca(2+), whole-cell Cl(-) currents, conductances and ASL height were inhibited by Boc-2, a specific antagonist of the ALX\\/FPR2 receptor. Our results provide, for the first time, evidence for a novel role of LXA(4) in the stimulation of intracellular Ca(2+) signalling leading to Ca(2+)-activated Cl(-) secretion and enhanced ASL height in non-CF and CF bronchial epithelia.

  19. Effect of Luffa aegyptiaca (seeds) and Carissa edulis (leaves) extracts on blood glucose level of normal and streptozotocin diabetic rats.

    Science.gov (United States)

    El-Fiky, F K; Abou-Karam, M A; Afify, E A

    1996-01-01

    The present study investigates the effect of oral administration of the ethanolic extracts of Luffa aegyptiaca (seeds) and Carissa edulis (leaves) on blood glucose levels both in normal and streptozotocin (STZ) diabetic rats. Treatment with both extracts significantly reduced the blood glucose level in STZ diabetic rats during the first three hours of treatment. L. aegyptiaca extract decreased blood glucose level with a potency similar to that of the biguanide, metformin. The total glycaemic areas were 589.61 +/- 45.62 mg/dl/3 h and 660.38 +/- 64.44 mg/dl/3 h for L. aegyptiaca and metformin, respectively, vs. 816.73 +/- 43.21 mg/dl/3 h for the control (P < 0.05). On the other hand, in normal rats, both treatments produced insignificant changes in blood glucose levels compared to glibenclamide treatment.

  20. Stabilization of liquid low-level and mixed wastes: a treatability study

    International Nuclear Information System (INIS)

    Carson, S.; Cheng, Yu-Cheng; Yellowhorse, L.; Peterson, P.

    1996-01-01

    A treatability study has been conducted on liquid low-level and mixed wastes using the stabilization agents Aquaset, Aquaset II, Aquaset II-H, Petroset, Petroset-H, and Petroset and Petroset II. A total of 40 different waste types with activities ranging from 10 -14 to 10 -4 curies/ml have been stabilized. Reported data for each waste include its chemical and radiological composition and the optimum composition or range of compositions (weight of agent/volume of waste) for each stabilization agent used. All wastes were successfully stabilized with one or more of the stabilization agents and all final waste forms passed the Paint Filter Liquids Test (EPA Method 9095)

  1. Molecular-level mechanisms of vibrational frequency shifts in a polar liquid.

    Science.gov (United States)

    Morales, Christine M; Thompson, Ward H

    2011-06-16

    A molecular-level analysis of the origins of the vibrational frequency shifts of the CN stretching mode in neat liquid acetonitrile is presented. The frequency shifts and infrared spectrum are calculated using a perturbation theory approach within a molecular dynamics simulation and are in good agreement with measured values reported in the literature. The resulting instantaneous frequency of each nitrile group is decomposed into the contributions from each molecule in the liquid and by interaction type. This provides a detailed picture of the mechanisms of frequency shifts, including the number of surrounding molecules that contribute to the shift, the relationship between their position and relative contribution, and the roles of electrostatic and van der Waals interactions. These results provide insight into what information is contained in infrared (IR) and Raman spectra about the environment of the probed vibrational mode. © 2011 American Chemical Society

  2. Transition Temperatures of Thermotropic Liquid Crystals from the Local Binary Gray Level Cooccurrence Matrix

    Directory of Open Access Journals (Sweden)

    S. Sreehari Sastry

    2012-01-01

    Full Text Available This paper presents a method which combines the statistical analysis with texture structural analysis called Local Binary Gray Level Cooccurrence Matrix (LBGLCM to investigate the phase transition temperatures of thermotropic p,n-alkyloxy benzoic acid (nOBA, n=4,6,8,10 and 12 liquid crystals. Textures of the homeotropically aligned liquid crystal compounds are recorded as a function of temperature using polarizing optical microscope attached to the hot stage and high resolution camera. In this method, second-order statistical parameters (contrast, energy, homogeneity, and correlation are extracted from the LBGLCM of the textures. The changes associatedwiththe values of extracted parameters as a function of temperature are a helpful process to identify the phases and phase transition temperatures of the samples. Results obtained from this method have validity and are in good agreement with the literature.

  3. FY 1995 separation studies for liquid low-level waste treatment at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Bostick, D.T.; Arnold, W.D.; Burgess, M.W.

    1995-01-01

    During FY 1995, studies were continued to develop improved methods for centralized treatment of liquid low-level waste (LLLW) at Oak Ridge National Laboratory (ORNL). Focus in this reporting period was on (1) identifying the parameters that affect the selective removal of 90 Sr and 137 Cs, two of the principal radioactive contaminants expected in the waste; (2) validating the effectiveness of the treatment methods by testing an ac Melton Valley Storage Tank (MVST) supernate; (3) evaluating the optimum solid/liquid separation techniques for the waste; (4) identifying potential treatment methods for removal of technetium from LLLW; and (5) identifying potential methods for stabilizing the high-activity secondary solid wastes generated by the treatment

  4. Insulin-like factor 3 serum levels in 135 normal men and 85 men with testicular disorders

    DEFF Research Database (Denmark)

    Bay, K; Hartung, S; Ivell, R

    2005-01-01

    Insulin-like factor 3 (INSL3) serum levels were measured in 135 andrologically well-characterized normal men and 85 patients with testicular disorders to investigate how the hormone, which is a major secretory product of human Leydig cells, is related to testosterone (T), LH, and semen quality. I...

  5. A Look at the Memory Performance of Retarded and Normal Children Utilizing the Levels of Processing Framework.

    Science.gov (United States)

    Lupart, Judy L.; Mulcahy, Robert F.

    Memory performance differences of mental age matched (9-12 years) educable mentally retarded (EMR) (n=56) and normal (n=56) children were examined in two experiments using the F. Craik and R. Lockhart levels of processing framework. In experiment 1, Ss were randomly assigned to an incidental, intentional, or planned intentional learning condition,…

  6. N-Acetylcysteine Normalizes Glutamate Levels in Cocaine-Dependent Patients: A Randomized Crossover Magnetic Resonance Spectroscopy Study

    NARCIS (Netherlands)

    Schmaal, Lianne; Veltman, Dick J.; Nederveen, Aart; van den Brink, Wim; Goudriaan, Anna E.

    2012-01-01

    Treatment with N-acetylcysteine (NAC) normalizes glutamate (Glu) homeostasis and prevents relapse in drug-dependent animals. However, the effect of NAC on brain Glu levels in substance-dependent humans has not yet been investigated. Proton magnetic resonance spectroscopy (H-1 MRS) was used to

  7. N-Acetylcysteine Normalizes Glutamate Levels in Cocaine-Dependent Patients: A Randomized Crossover Magnetic Resonance Spectroscopy Study

    NARCIS (Netherlands)

    Schmaal, L.; Veltman, D.J.; Nederveen, A.; van den Brink, W.; Goudriaan, A.E.

    2012-01-01

    Treatment with N-acetylcysteine (NAC) normalizes glutamate (Glu) homeostasis and prevents relapse in drug-dependent animals. However, the effect of NAC on brain Glu levels in substance-dependent humans has not yet been investigated. Proton magnetic resonance spectroscopy (1 H MRS) was used to

  8. Children with severe Osteogenesis imperfecta and short stature present on average with normal IGF-I and IGFBP-3 levels.

    Science.gov (United States)

    Hoyer-Kuhn, Heike; Höbing, Laura; Cassens, Julia; Schoenau, Eckhard; Semler, Oliver

    2016-07-01

    Osteogenesis imperfecta (OI) is characterized by bone fragility and short stature. Data about IGF-I/IGFBP-3 levels are rare in OI. Therefore IGF-I/IGFBP-3 levels in children with different types of OI were investigated. IGF-I and IGFBP-3 levels of 60 children (male n=38) were assessed in a retrospective cross-sectional setting. Height/weight was significant different [height z-score type 3 versus type 4: p=0.0011 and weight (p≤0.0001)] between OI type 3 and 4. Mean IGF-I levels were in the lower normal range (mean±SD level 137.4±109.1 μg/L). Mean IGFBP-3 measurements were in the normal range (mean±SD 3.105±1.175 mg/L). No significant differences between OI type 3 and 4 children have been observed (IGF-I: p=0.0906; IGFBP-3: p=0.2042). Patients with different severities of OI have IGF-I and IGFBP-3 levels in the lower normal range. The type of OI does not significantly influence these growth factors.

  9. Immunoconglutinin levels in normal and diseased population groups in Southern Africa

    Science.gov (United States)

    Watson, K. C.

    1971-01-01

    Immunoconglutinin (I-K) levels were measured in adult blood donors of European and African origin and in patients with the following diseases: acute typhoid fever, amoebic liver abscess, chronic liver disease and primary hepatoma. The lowest levels were found in the white donor group and the highest in those with chronic liver disease and those with primary hepatoma. African donors had levels higher than white donors which may relate to chronic infection and particularly chronic parasitic infestation. There was poor correlation between `O' and `H' antibodies and I-K levels in the typhoid group. In those with chronic liver disease there was some correlation between I-K levels and total γ-globulin and also with raised IgM and IgA levels but not with raised IgG. PMID:4103887

  10. Development of Fe-based superconducting wires for liquid-hydrogen level sensors

    Science.gov (United States)

    Ishida, S.; Tsuchiya, Y.; Mawatari, Y.; Eisaki, H.; Nakano, A.; Yoshida, Y.

    2017-07-01

    We developed liquid-hydrogen (LH2) level sensors with Ba(Fe1-x Co x )2As2 superconducting wires (Co-Ba122 wires) as their detection elements. We fabricated Co-Ba122 wires with different Co concentrations x by using the powder-in-tube method. The superconducting transition temperatures of the wires were successfully controlled in the range of 20-25 K by changing x from 0.06 to 0.10. The resistance-temperature curves of the wires exhibited sharp superconducting transitions with widths of 0.5-1.0 K. In addition, we performed an operation test of the Co-Ba122 level sensors with LH2. Close correspondence between the output resistance and the actual LH2 level was observed for a sensor equipped with x = 0.09 wire, demonstrating that this sensor can accurately measure LH2 levels.

  11. Design and construction of an optical sensor for liquid level control

    International Nuclear Information System (INIS)

    Razani, M.; Golnabi, H.; Dabbaghian, M. H.; Dariani, R. S.; Vaziri, N.; Hojabri, A.

    2010-01-01

    Design and construction of an optical sensor for liquid level control is reported here. Operation of this sensor is based on the intensity modulation. The modulated light intensity is detected by total internal reflection in a prism. The variation of output intensity is measured by an optical detector and is monitored by a digital voltmeter. This optical fiber sensor is used for water level measurement in this experiment. For a white light source, the output voltage in the case of low water level is equal to 480 mV and when the water level reaches to prism reduced to 8 mV. Height measurement accuracy in this system is about ±1mm.

  12. Calibration of a liquid scintillation counter to assess tritium levels in various samples

    CERN Document Server

    Al-Haddad, M N; Abu-Jarad, F A

    1999-01-01

    An LKB-Wallac 1217 Liquid Scintillation Counter (LSC) was calibrated with a newly adopted cocktail. The LSC was then used to measure tritium levels in various samples to assess the compliance of tritium levels with the recommended international levels. The counter was calibrated to measure both biological and operational samples for personnel and for an accelerator facility at KFUPM. The biological samples include the bioassay (urine), saliva, and nasal tests. The operational samples of the light ion linear accelerator include target cooling water, organic oil, fomblin oil, and smear samples. Sets of standards, which simulate various samples, were fabricated using traceable certified tritium standards. The efficiency of the counter was obtained for each sample. The typical range of the efficiencies varied from 33% for smear samples down to 1.5% for organic oil samples. A quenching curve for each sample is presented. The minimum detectable activity for each sample was established. Typical tritium levels in bio...

  13. Insulin Resistance and Serum Levels of Interleukin-17 and Interleukin-18 in Normal Pregnancy

    OpenAIRE

    Jahromi, Abdolreza Sotoodeh; Shojaei, Mohammad; Ghobadifar, Mohamed Amin

    2014-01-01

    We performed this study to evaluate the role of Interleukin-17 (IL-17) and Interleukin-18 (IL-18) in insulin resistance during normal pregnancy. This descriptive cross sectional study was carried out on 97 healthy pregnant women including 32, 25, and 40 individuals in the first, second, and third trimesters, respectively, and on 28 healthy non pregnant women between the autumn of 2012 and the spring of 2013. We analyzed the serum concentrations of IL-17 and IL-18 by using the enzyme linked im...

  14. A case of moderate liver enzyme elevation after acute acetaminophen overdose despite undetectable acetaminophen level and normal initial liver enzymes.

    Science.gov (United States)

    Bebarta, Vikhyat S; Shiner, Drew C; Varney, Shawn M

    2014-01-01

    Liver function test (LFT) increase is an early sign of acetaminophen (APAP) toxicity. Typically, when an acute overdose patient is evaluated and has an initial undetectable APAP level and normal liver enzymes, the patient is not treated with N-acetylcysteine, and liver enzymes are not expected to increase later. We report a case of moderate LFT increase despite normal LFTs and an undetectable APAP level after delayed presentation of an APAP ingestion. A 22-year-old male with no medical history ingested 15-25 hydrocodone/APAP tablets (5 mg/500 mg). His suicide note and his bunkmate corroborated the overdose time. He arrived at the emergency department 16 hours after ingestion. At that time, his APAP level was enzymes were normal [aspartate transaminase (AST) 31 U/L and alanine transaminase (ALT) 34 U/L]. Twenty-nine hours after ingestion, the psychiatry team obtained LFTs (AST 45, ALT 61). He had persistent nausea and diffuse abdominal pain. On repeat analysis, the APAP level at 36 hours was found to be <10 μg/mL, AST 150, and ALT 204. After 2 more days of increasing LFTs and persistent abdominal pain and nausea, the toxicology department was consulted, the patient was transferred to the medicine department, and intravenous N-acetylcysteine was started 66 hours after ingestion. He was treated for 16 hours and had a significant decline in LFTs and symptom resolution. His prothrombin time, bilirubin, lactate, creatinine, and mental status were normal throughout the admission. Other cases of LFT increase were excluded. Our case report illustrates that a moderate increase in liver transaminase may occur despite an initial undetectable APAP level and normal transaminases after a delayed presentation. In our case, no serious clinical effects were reported.

  15. [Prevalence of dyslipidemia and normal blood lipids level in Uygur population in Kashgar area of Xinjiang Uygur Autonomous Region].

    Science.gov (United States)

    Zhang, Z B; Xue, Z X; Wu, X J; Wang, T M; Li, Y H; Song, X L; Chao, X F; Wang, G; Nazibam, Nurmamat; Ayxamgul, Bawudun; Gulbahar, Elyas; Zhou, Z Y; Sun, B S; Wang, Y Z; Wang, M

    2017-06-10

    Objective: To understand the prevalence of dyslipidemia and normal blood lipids level in Uygur diabetes patients in Kashgar prefecture in southern area of Xinjiang. Methods: A total of 5 078 local residents aged ≥18 years (42.56 % were men) selected through cluster random sampling in Kashgar were surveyed by means of questionnaire survey, physical examination and laboratory test, and 521 diabetes patients were screened. Results: The overall prevalence of dyslipidemia in diabetes patients was 59.50 % (310/521) with adjusted rate as 49.39 % . Age ≥65 years, overweight, obesity and abdominal obesity increased the risk for dyslipidemia by 0.771 times (95 % CI : 1.015-3.088), 1.132 times (95 % CI : 1.290-3.523), 1.688 times (95 % CI : 1.573-4.592) and 0.801 times (95 % CI : 1.028-3.155) respectively. Compared with males, female was a protective factor for dyslipidemia ( OR =0.507, 95 %CI : 0.334-0.769). The overall normal rate of blood lipids level including total cholesterol (TC), triglycerides (TG), high-density lipoprotein cholesterol (HDL-C) and low-density lipoprotein cholesterol (LDL-C) for type 2 diabetes patients was 11.13 % . Female, higher BMI and abdominal obesity were the factors influencing the overall normal blood lipids level. The normal rate of LDL-C level decreased with increase of age, BMI and waist circumferences (trend test χ (2)=18.049, P dyslipidemia in Uygur diabetes patients in Kashgar was high, however, the overall normal rate of blood lipid level was relatively low. Obesity was the most important risk factor for dyslipidemia in this area. More attention should be paid to dyslipidemia prevention in women.

  16. Multiple chromosome aberrations among newborns from high level natural radiation area and normal level natural radiation area of south west coast of Kerala

    International Nuclear Information System (INIS)

    Soren, D.C.; Ramachandran, E.N.; Karuppasamy, C.V.; Cheriyan, V.D.; Anil Kumar, V.; Koya, P.K.M.; Seshadri, M.

    2010-01-01

    Cord blood samples were collected in heparin vials and microculture techniques employed to obtain good metaphase chromosome spreads. In cytogenetic studies on newborns cells with multiple aberrations were recorded in 57 from a total of 27285 newborns (1266972 cells). Of these 17294 newborns (964140 cells) were from High Level Natural Radiation Area (HLNRA) and 9991 newborns (302832 cells) from Normal Level Natural Radiation Area (NLNRA). Cells with multiple aberrations were observed in 38 and 19 newborns from High and Normal Level Natural Radiation Area respectively. On an average one cell with multiple aberrations was observed among 479 newborns. Cells with multiple aberrations were observed in newborns from HLNRA as well as NLNRA in both males and females. Gender difference of newborns, maternal age group and background radiation levels did not seem to have any influence in the occurrence of Multiple chromosome aberrations

  17. Intravenous erythromycin dramatically accelerates gastric emptying in gastroparesis diabeticorum and normals and abolishes the emptying discrimination between solids and liquids

    International Nuclear Information System (INIS)

    Urbain, J.L.; Vantrappen, G.; Janssens, J.; Van Cutsem, E.; Peeters, T.; De Roo, M.

    1990-01-01

    Erythromycin, a macrolide antibiotic, has recently been shown to have a motilin like effect on gastrointestinal muscle strips. In this study, we have evaluated the effect of erythromycin on patients with delayed gastric emptying and healthy subjects using the dual radionuclide technique. Twelve patients with gastroparesis diabeticorum and ten healthy age- and sex-matched controls were studied. Gastric emptying of solids and liquids was determined using 99mTc-SC scrambled egg and 111In-DTPA in water. Following a baseline study and on a separate day, each patient and control received a 15-min i.v. perfusion of erythromycin starting at meal ingestion. Eleven out of the 12 patients were restudied after a 3-wk oral administration. In patients and controls, i.v. erythromycin dramatically accelerated gastric emptying of both solids and liquids which were emptied at the same rate. After chronic oral administration, solid and liquid emptying remained significantly accelerated. Erythromycin appears to be a very powerful gastrokinetic drug. Derived compounds with the gastrokinetic effect and without the antibiotic activity could be useful in dyspeptic patients with delayed gastric emptying

  18. Intravenous erythromycin dramatically accelerates gastric emptying in gastroparesis diabeticorum and normals and abolishes the emptying discrimination between solids and liquids

    Energy Technology Data Exchange (ETDEWEB)

    Urbain, J.L.; Vantrappen, G.; Janssens, J.; Van Cutsem, E.; Peeters, T.; De Roo, M. (Univ. of Leuven (Belgium))

    1990-09-01

    Erythromycin, a macrolide antibiotic, has recently been shown to have a motilin like effect on gastrointestinal muscle strips. In this study, we have evaluated the effect of erythromycin on patients with delayed gastric emptying and healthy subjects using the dual radionuclide technique. Twelve patients with gastroparesis diabeticorum and ten healthy age- and sex-matched controls were studied. Gastric emptying of solids and liquids was determined using 99mTc-SC scrambled egg and 111In-DTPA in water. Following a baseline study and on a separate day, each patient and control received a 15-min i.v. perfusion of erythromycin starting at meal ingestion. Eleven out of the 12 patients were restudied after a 3-wk oral administration. In patients and controls, i.v. erythromycin dramatically accelerated gastric emptying of both solids and liquids which were emptied at the same rate. After chronic oral administration, solid and liquid emptying remained significantly accelerated. Erythromycin appears to be a very powerful gastrokinetic drug. Derived compounds with the gastrokinetic effect and without the antibiotic activity could be useful in dyspeptic patients with delayed gastric emptying.

  19. Insulin resistance and serum levels of interleukin-17 and interleukin-18 in normal pregnancy.

    Science.gov (United States)

    Jahromi, Abdolreza Sotoodeh; Shojaei, Mohammad; Ghobadifar, Mohamed Amin

    2014-06-01

    We performed this study to evaluate the role of Interleukin-17 (IL-17) and Interleukin-18 (IL-18) in insulin resistance during normal pregnancy. This descriptive cross sectional study was carried out on 97 healthy pregnant women including 32, 25, and 40 individuals in the first, second, and third trimesters, respectively, and on 28 healthy non pregnant women between the autumn of 2012 and the spring of 2013. We analyzed the serum concentrations of IL-17 and IL-18 by using the enzyme linked immunosorbent assay (ELISA). Insulin resistance was measured by homeostasis model assessment of insulin resistance equation. No significant differences between the demographic data of the pregnant and non pregnant groups were observed. Insulin resistant in pregnant women was significantly higher than the controls (p=0.006). Serum IL-17 concentration was significantly different in non pregnant women and pregnant women in all gestational ages (ppregnant women (pinsulin resistance (r=0.08, p=0.34 vs. r=0.01, p=0.91, respectively). Our data suggested that IL-17 and IL-18 do not appear to attribute greatly to pregnancy deduced insulin resistance during normal pregnancy.

  20. Cognitive levels of performance account for hemispheric lateralisation effects in dyslexic and normally reading children.

    Science.gov (United States)

    Heim, Stefan; Grande, Marion; Meffert, Elisabeth; Eickhoff, Simon B; Schreiber, Helen; Kukolja, Juraj; Shah, Nadim Jon; Huber, Walter; Amunts, Katrin

    2010-12-01

    Recent theories of developmental dyslexia explain reading deficits in terms of deficient phonological awareness, attention, visual and auditory processing, or automaticity. Since dyslexia has a neurobiological basis, the question arises how the reader's proficiency in these cognitive variables affects the brain regions involved in visual word recognition. This question was addressed in two fMRI experiments with 19 normally reading children (Experiment 1) and 19 children with dyslexia (Experiment 2). First, reading-specific brain activation was assessed by contrasting the BOLD signal for reading aloud words vs. overtly naming pictures of real objects. Next, ANCOVAs with brain activation during reading the individuals' scores for all five cognitive variables assessed outside the scanner as covariates were performed. Whereas the normal readers' brain activation during reading showed co-variation effects predominantly in the right hemisphere, the reverse pattern was observed for the dyslexics. In particular, middle frontal gyrus, inferior parietal cortex, and precuneus showed contralateral effects for controls as compared to dyslexics. In line with earlier findings in the literature, these data hint at a global change in hemispheric asymmetry during cognitive processing in dyslexic readers, which, in turn, might affect reading proficiency. Copyright © 2010 Elsevier Inc. All rights reserved.

  1. Normal Theory Two-Stage ML Estimator When Data Are Missing at the Item Level.

    Science.gov (United States)

    Savalei, Victoria; Rhemtulla, Mijke

    2017-08-01

    In many modeling contexts, the variables in the model are linear composites of the raw items measured for each participant; for instance, regression and path analysis models rely on scale scores, and structural equation models often use parcels as indicators of latent constructs. Currently, no analytic estimation method exists to appropriately handle missing data at the item level. Item-level multiple imputation (MI), however, can handle such missing data straightforwardly. In this article, we develop an analytic approach for dealing with item-level missing data-that is, one that obtains a unique set of parameter estimates directly from the incomplete data set and does not require imputations. The proposed approach is a variant of the two-stage maximum likelihood (TSML) methodology, and it is the analytic equivalent of item-level MI. We compare the new TSML approach to three existing alternatives for handling item-level missing data: scale-level full information maximum likelihood, available-case maximum likelihood, and item-level MI. We find that the TSML approach is the best analytic approach, and its performance is similar to item-level MI. We recommend its implementation in popular software and its further study.

  2. Normal Morning MCH Levels and No Association with REM or NREM Sleep Parameters in Narcolepsy Type 1 and Type 2

    DEFF Research Database (Denmark)

    Schrölkamp, Maren; Jennum, Poul J; Gammeltoft, Steen

    2017-01-01

    in rapid eye movement (REM) and nonrapid eye movement (NREM) sleep regulation. Hypocretin neurons reciprocally interact with MCH neurons. We hypothesized that altered MCH secretion contributes to the symptoms and sleep abnormalities of narcolepsy and that this is reflected in morning cerebrospinal fluid...... MCH levels. CONCLUSION: Our study shows that MCH levels in CSF collected in the morning are normal in narcolepsy and not associated with the clinical symptoms, REM sleep abnormalities, nor number of muscle movements during REM or NREM sleep of the patients. We conclude that morning lumbar CSF MCH......STUDY OBJECTIVES: Other than hypocretin-1 (HCRT-1) deficiency in narcolepsy type 1 (NT1), the neurochemical imbalance of NT1 and narcolepsy type 2 (NT2) with normal HCRT-1 levels is largely unknown. The neuropeptide melanin-concentrating hormone (MCH) is mainly secreted during sleep and is involved...

  3. Acromegaly with Normal Insulin-Like Growth Factor-1 Levels and Congestive Heart Failure as the First Clinical Manifestation

    Directory of Open Access Journals (Sweden)

    Hyae Min Lee

    2015-09-01

    Full Text Available The leading cause of morbidity and mortality in patients with acromegaly is cardiovascular complications. Myocardial exposure to excessive growth hormone can cause ventricular hypertrophy, hypertension, arrhythmia, and diastolic dysfunction. However, congestive heart failure as a result of systolic dysfunction is observed only rarely in patients with acromegaly. Most cases of acromegaly exhibit high levels of serum insulin-like growth factor-1 (IGF-1. Acromegaly with normal IGF-1 levels is rare and difficult to diagnose. Here, we report a rare case of an acromegalic patient whose first clinical manifestation was severe congestive heart failure, despite normal IGF-1 levels. We diagnosed acromegaly using a glucose-loading growth hormone suppression test. Cardiac function and myocardial hypertrophy improved 6 months after transsphenoidal resection of a pituitary adenoma.

  4. Treatment of low-level radioactive waste liquid by reverse osmosis

    International Nuclear Information System (INIS)

    Buckley, L.P.; Sen Gupta, S.K.; Slade, J.A.

    1995-01-01

    The processing of low-level radioactive waste (LLRW) liquids that result from operation of nuclear power plants with reverse osmosis systems is not common practice. A demonstration facility is operating at Chalk River Laboratories (of Atomic Energy of Canada Limited), processing much of the LLRW liquids generated at the site from a multitude of radioactive facilities, ranging from isotope production through decontamination operations and including chemical laboratory drains. The reverse osmosis system comprises two treatment steps--spiral wound reverse osmosis followed by tubular reverse osmosis--to achieve an average volume reduction factor of 30:1 and a removal efficiency in excess of 99% for most radioactive and chemical species. The separation allows the clean effluent to be discharged without further treatment. The concentrated waste stream of 3 wt% total solids is further processed to generate a solid product. The typical lifetimes of the membranes have been nearly 4000 hours, and replacement was required based on increased pressure drops and irreversible loss of permeate flux. Four years of operating experience with the reverse osmosis system, to demonstrate its practicality and to observe and record its efficiency, maintenance requirements and effectiveness, have proven it to be viable for volume reduction and concentration of LLRW liquids generated from nuclear-power-plant operations

  5. Develop of analytic method for the determination of vitamin D3 in multivitaminics and minerals using chromatography it liquidates of high efficiency in normal phase with ultraviolet detection

    International Nuclear Information System (INIS)

    Solis Barrantes, J. A.

    1999-01-01

    The good chromatography conditions settled down for the determination vitamin D 3 in multivitaminic samples by means of the analytic technique of chromatography it liquidates of high efficiency (HPLC) in normal phase, with ultraviolet detection to 265 nm. The best conditions in the proposed methodology settled down and the variables of analytic acting were validated, for the analytic quantification of vitamin D 3 in International units. The applicability of the methodology was demonstrated in the vitamin determination D 3 in multivitaminis samples in pill form [es

  6. Biochemical process of low level radioactive liquid simulation waste containing detergent

    International Nuclear Information System (INIS)

    Kundari, Noor Anis; Putra, Sugili; Mukaromah, Umi

    2015-01-01

    Research of biochemical process of low level radioactive liquid waste containing detergent has been done. Thse organic liquid wastes are generated in nuclear facilities such as from laundry. The wastes that are cotegorized as hazard and poison materials are also radioactive. It must be treated properly by detoxification of the hazard and decontamination of the radionuclides to ensure that the disposal of the waste meets the requirement of standard quality of water. This research was intended to determine decontamination factor and separation efficiensies, its kinetics law, and to produce a supernatant that ensured the environmental quality standard. The radioactive element in the waste was thorium with activity of 5.10 −5 Ci/m 3 . The radioactive liquid waste which were generated in simulation plant contains detergents that was further processed by aerobic biochemical process using SGB 103 bacteria in a batch reactor equipped with aerators. Two different concentration of samples were processed and analyzed for 212 hours and 183 hours respectively at a room temperature. The product of this process is a liquid phase called as supernatant and solid phase material called sludge. The chemical oxygen demand (COD), biological oxygen demand (BOD), suspended solid (SS), and its alpha activity were analyzed. The results show that the decontamination factor and the separation efficiency of the lower concentration samples are higher compared to the samples with high concentration. Regarding the decontamination factor, the result for 212 hours processing of waste with detergent concentration of 1.496 g/L was 3.496 times, whereas at the detergent concentration of 0.748 g/L was 15.305 times for 183 hours processing. In case of the separation efficiency, the results for both samples were 71.396% and 93.465% respectively. The Bacterial growth kinetics equation follow Monod’s model and the decreasing of COD and BOD were first order with the rate constant of 0.01 hour −1

  7. Biochemical process of low level radioactive liquid simulation waste containing detergent

    Energy Technology Data Exchange (ETDEWEB)

    Kundari, Noor Anis, E-mail: nooranis@batan.go.id; Putra, Sugili; Mukaromah, Umi [Sekolah Tinggi Teknologi Nuklir – Badan Tenaga Nuklir Nasional Jl. Babarsari P.O. BOX 6101 YKBB Yogyakarta 55281 Telp : (0274) 48085, 489716, Fax : (0274) 489715 (Indonesia)

    2015-12-29

    Research of biochemical process of low level radioactive liquid waste containing detergent has been done. Thse organic liquid wastes are generated in nuclear facilities such as from laundry. The wastes that are cotegorized as hazard and poison materials are also radioactive. It must be treated properly by detoxification of the hazard and decontamination of the radionuclides to ensure that the disposal of the waste meets the requirement of standard quality of water. This research was intended to determine decontamination factor and separation efficiensies, its kinetics law, and to produce a supernatant that ensured the environmental quality standard. The radioactive element in the waste was thorium with activity of 5.10{sup −5} Ci/m{sup 3}. The radioactive liquid waste which were generated in simulation plant contains detergents that was further processed by aerobic biochemical process using SGB 103 bacteria in a batch reactor equipped with aerators. Two different concentration of samples were processed and analyzed for 212 hours and 183 hours respectively at a room temperature. The product of this process is a liquid phase called as supernatant and solid phase material called sludge. The chemical oxygen demand (COD), biological oxygen demand (BOD), suspended solid (SS), and its alpha activity were analyzed. The results show that the decontamination factor and the separation efficiency of the lower concentration samples are higher compared to the samples with high concentration. Regarding the decontamination factor, the result for 212 hours processing of waste with detergent concentration of 1.496 g/L was 3.496 times, whereas at the detergent concentration of 0.748 g/L was 15.305 times for 183 hours processing. In case of the separation efficiency, the results for both samples were 71.396% and 93.465% respectively. The Bacterial growth kinetics equation follow Monod’s model and the decreasing of COD and BOD were first order with the rate constant of 0

  8. Biochemical process of low level radioactive liquid simulation waste containing detergent

    Science.gov (United States)

    Kundari, Noor Anis; Putra, Sugili; Mukaromah, Umi

    2015-12-01

    Research of biochemical process of low level radioactive liquid waste containing detergent has been done. Thse organic liquid wastes are generated in nuclear facilities such as from laundry. The wastes that are cotegorized as hazard and poison materials are also radioactive. It must be treated properly by detoxification of the hazard and decontamination of the radionuclides to ensure that the disposal of the waste meets the requirement of standard quality of water. This research was intended to determine decontamination factor and separation efficiensies, its kinetics law, and to produce a supernatant that ensured the environmental quality standard. The radioactive element in the waste was thorium with activity of 5.10-5 Ci/m3. The radioactive liquid waste which were generated in simulation plant contains detergents that was further processed by aerobic biochemical process using SGB 103 bacteria in a batch reactor equipped with aerators. Two different concentration of samples were processed and analyzed for 212 hours and 183 hours respectively at a room temperature. The product of this process is a liquid phase called as supernatant and solid phase material called sludge. The chemical oxygen demand (COD), biological oxygen demand (BOD), suspended solid (SS), and its alpha activity were analyzed. The results show that the decontamination factor and the separation efficiency of the lower concentration samples are higher compared to the samples with high concentration. Regarding the decontamination factor, the result for 212 hours processing of waste with detergent concentration of 1.496 g/L was 3.496 times, whereas at the detergent concentration of 0.748 g/L was 15.305 times for 183 hours processing. In case of the separation efficiency, the results for both samples were 71.396% and 93.465% respectively. The Bacterial growth kinetics equation follow Monod's model and the decreasing of COD and BOD were first order with the rate constant of 0.01 hour-1.

  9. Effect of passive smoking on the levels of pregnancy associated plasma protein-A in normal rats

    International Nuclear Information System (INIS)

    Naveed, A.K.; Rahim, A.; Malik, M.S.

    2010-01-01

    To measure the levels of pregnancy associated plasma protein- A (PAPPA-A) in normal rats exposed to cigarette smoke. Sixty albino rats of Sprague- Dawley strain weighing 200-250 gm, divided into two groups. Both the groups were kept in identical chambers. One group of 30 rats was further exposed to passive cigarette smoke for 4 weeks. No increase was observed in the levels of serum PAPP-A of both the groups: Passive smokers and not exposed to passive smoking i.e. P > 0.05. Smoking does not increase the levels of PAPP-A. (author)

  10. Median-lower normal levels of serum thyroxine are associated with low triiodothyronine levels and body temperature in patients with central hypothyroidism.

    Science.gov (United States)

    Hirata, Yu; Fukuoka, Hidenori; Iguchi, Genzo; Iwahashi, Yasuyuki; Fujita, Yasunori; Hari, Yusuke; Iga, Makiko; Nakajima, Shinsuke; Nishimoto, Yuki; Mukai, Miki; Hirota, Yushi; Sakaguchi, Kazuhiko; Ogawa, Wataru; Takahashi, Yutaka

    2015-08-01

    Although it has been recommended that serum free thyroxine (FT4) levels should be targeted to middle-upper normal levels during levothyroxine (l-T4) replacement therapy in patients with central hypothyroidism (CeH), the rationale has not been clarified. A retrospective single-center study enrolled 116 patients with hypothyroidism (CeH, n=32; total thyroidectomy (Tx), n=22; primary hypothyroidism (PH), n=33; and control benign thyroid nodule (C), n=29). The patients had received L-T4 therapy at the Kobe University Hospital between 2003 and 2013. They were stratified according to serum FT4 level (≥ 1.10 or triiodothyronine (FT3) levels, FT3/FT4 ratio, and lipid profiles were compared. The effect of GH replacement therapy on thyroid function was also analyzed. FT3 levels and FT3/FT4 ratios were significantly lower in patients with CeH than in patients with PH (P<0.05) or C (P<0.05). In patients with FT4 <1.10 ng/dl, BT was significantly lower in patients with CeH (P=0.002) and Tx (P=0.005) than in patients with PH, whereas no differences were found in patients with FT4 ≥ 1.10 ng/dl. In patients with CeH, FT3 levels were higher in those with GH replacement therapy (P=0.018). In CeH, patients with median-lower normal levels of serum FT4 exhibited lower serum FT3 levels and lower BT. These results support the target levels of serum FT4 as middle-upper normal levels during l-T4 replacement therapy in patients with CeH. © 2015 European Society of Endocrinology.

  11. Use of Eichornia crassipes for treatment of low level liquid radioactive waste

    Energy Technology Data Exchange (ETDEWEB)

    Hafez, N.; Ramadan, Y.S.; Hassanin, R.A.; Gafez, M.B. (Atomic Energy Authority, Hot Lab. Center, Cairo (Egypt))

    1993-01-01

    Radioactive and non-radioactive isotopes of cobalt, cerium and cesium were found to be accumulated inside Eichornia crassipes (the water hyacinth). The rate and extent of accumulation were dependent upon environmental parameters such as pH, temperature and interference by certain anions and cations. The accumulation rate of radioactive isotopes inside Eichornia crassipes, were more rapid than non-active ions. The results showed that accumulation of such metals inside the plant could be used successfully in the treatment of low-level liquid radioactive wastes. (author) 4 figs., 2 tabs., 15 refs.

  12. Use of Eichornia crassipes for treatment of low level liquid radioactive waste

    International Nuclear Information System (INIS)

    Hafez, N.; Ramadan, Y.S.; Hassanin, R.A.; Gafez, M.B.

    1993-01-01

    Radioactive and non-radioactive isotopes of cobalt, cerium and cesium were found to be accumulated inside Eichornia crassipes (the water hyacinth). The rate and extent of accumulation were dependent upon environmental parameters such as pH, temperature and interference by certain anions and cations. The accumulation rate of radioactive isotopes inside Eichornia crassipes, were more rapid than non-active ions. The results showed that accumulation of such metals inside the plant could be used successfully in the treatment of low-level liquid radioactive wastes. (author) 4 figs., 2 tabs., 15 refs

  13. Denaturing high-performance liquid chromatography mutation analysis in patients with reduced Protein S levels

    DEFF Research Database (Denmark)

    Bathum, Lise; Münster, Anna-Marie; Nybo, Mads

    2008-01-01

    diagnosis and risk estimation. The aim was to design a high-throughput genetic analysis based on denaturing high-performance liquid chromatography to identify sequence variations in the gene coding for Protein S. PATIENTS: In total, 55 patients referred to the Section of Thrombosis and Haemostasis, Odense......BACKGROUND: Patients with congenital Protein S deficiency have increased risk of venous thromboembolism. However, Protein S levels show large intra-individual variation and the biochemical assays have low accuracy and a high interlaboratory variability. Genetic analysis might aid in a more precise......, giving a precise diagnosis and subsequently a better risk estimation....

  14. Development of an improved-contact liquid-level probe for pressurized reactor vessels

    International Nuclear Information System (INIS)

    Kelsey, P.V. Jr.

    1982-09-01

    Electrical-conductivity-based probes for liquid level sensing show promise for pressurized water reactor environments, but have exhibited frequent bond failures at the ceramic/metal interfaces. A program to characterize and improve the interface behavior has been completed successfully, and has provided data for optimizing fabrication parameters, as well as general information on glass-to-metal bonding in a superalloy/silicate-glass system. The materials studied were Inconel X-750 and a barium silicate glass containing minor amounts of TiO 2 , CeO 2 , As 2 O 3 , Bi 2 O 3 , and Al 2 O 3

  15. Volatilization behavior of semivolatile elements in vitrification of high-level liquid waste

    International Nuclear Information System (INIS)

    Igarashi, Hiroshi; Kato, Koh; Takahashi, Takeshi

    1991-11-01

    The effect of temperature on the volatilization of ruthenium, technetium, and selenium was observed in calcination experiments with simulated high-level liquid waste. Technetium and selenium were more volatile as calcining temperature increased. Ruthenium was less volatile when temperature exceeded 300degC. More than 80% of ruthenium that volatilized from room temperature to 500degC occurred between 200 and 300degC. A small amount of ruthenium volatilized above 300degC as well as below 135degC. (author)

  16. Seismic scoping evaluation of high level liquid waste tank vaults at the Idaho Chemical Processing Plant

    International Nuclear Information System (INIS)

    Hashimoto, P.S.; Uldrich, E.D.; McGee, W.D.

    1991-01-01

    A seismic scoping evaluation of buried vaults enclosing high level liquid waste storage tanks at the Idaho Chemical Processing Plant has been performed. The objective of this evaluation was to scope out which of the vaults could be demonstrated to be seismically adequate against the Safe Shutdown Earthquake (SSE). Using approximate analytical methods, earthquake experience data, and engineering judgement, this study determined that one vault configuration would be expected to meet ICPP seismic design criteria, one would not be considered seismically adequate against the SSE, and one could be shown to be seismically adequate against the SSE using nonlinear analysis

  17. SU-E-T-573: Normal Tissue Dose Effect of Prescription Isodose Level Selection in Lung Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Zhang, Q; Lei, Y; Zheng, D; Zhu, X; Wahl, A; Lin, C; Zhou, S; Zhen, W

    2015-01-01

    Purpose: To evaluate dose fall-off in normal tissue for lung stereotactic body radiation therapy (SBRT) cases planned with different prescription isodose levels (IDLs), by calculating the dose dropping speed (DDS) in normal tissue on plans computed with both Pencil Beam (PB) and Monte-Carlo (MC) algorithms. Methods: The DDS was calculated on 32 plans for 8 lung SBRT patients. For each patient, 4 dynamic conformal arc plans were individually optimized for prescription isodose levels (IDL) ranging from 60% to 90% of the maximum dose with 10% increments to conformally cover the PTV. Eighty non-overlapping rind structures each of 1mm thickness were created layer by layer from each PTV surface. The average dose in each rind was calculated and fitted with a double exponential function (DEF) of the distance from the PTV surface, which models the steep- and moderate-slope portions of the average dose curve in normal tissue. The parameter characterizing the steep portion of the average dose curve in the DEF quantifies the DDS in the immediate normal tissue receiving high dose. Provided that the prescription dose covers the whole PTV, a greater DDS indicates better normal tissue sparing. The DDS were compared among plans with different prescription IDLs, for plans computed with both PB and MC algorithms. Results: For all patients, the DDS was found to be the lowest for 90% prescription IDL and reached a highest plateau region for 60% or 70% prescription. The trend was the same for both PB and MC plans. Conclusion: Among the range of prescription IDLs accepted by lung SBRT RTOG protocols, prescriptions to 60% and 70% IDLs were found to provide best normal tissue sparing

  18. Cord Blood Ischemia-Modified Albumin Levels in Normal and Intrauterine Growth Restricted Pregnancies

    Directory of Open Access Journals (Sweden)

    Nicoletta Iacovidou

    2008-01-01

    Full Text Available Ischemia-modified albumin (IMA is a sensitive biomarker of cardiac ischemia. Intrauterine growth restriction (IUGR may imply fetal hypoxia, resulting in blood flow centralization in favour of vital organs (brain, heart, adrenals—‘‘brain sparing effect’’. Based on the latter, we hypothesized that cord blood IMA levels should not differ between IUGR and appropriate-for-gestational-age (AGA full-term pregnancies. IMA was measured in blood samples from doubly-clamped umbilical cords of 110 AGA and 57 asymmetric IUGR pregnancies. No significant differences in IMA levels were documented between AGA and IUGR groups. IMA levels were elevated in cases of elective cesarean section (P = .035, and offspring of multigravidas (P = .021. In conclusion, ‘‘brain sparing effect’’ is possibly responsible for the lack of differences in cord blood IMA levels at term, between IUGR and AGA groups. Furthermore, higher oxidative stress could account for the elevated IMA levels in cases of elective cesarean section, and offspring of multigravidas.

  19. ACUTE RENAL FAILURE WITH NORMAL PLASMA UREA LEVEL SECONDARY TO ACUTE PYELONEPHITIS IN A SINGLE KIDNEY PATIENT

    Directory of Open Access Journals (Sweden)

    Imperiali N

    2006-03-01

    Full Text Available SUMMARYAcute renal failure is a syndrome that usually runs with an increase in creatinine and urea plasma levels. However, there are clinical situations in which this syndrome may run with an increase in plasma creatinine keeping normal the urea one.In this report we present a case of acute renal failure with normal plasma urea level secondary to an acute pyelonephritis in a single kidney patient. The patient had an increased fractional excretion of urea which could explain the normal plasma urea levels found despite of his reduced glomerular filtration. This increased urea excretion state was interpreted as a consequence of the nephrogenic diabetes insipidus and alteration of the intra-renal urea reciclying process that the acute pyelonephritis induced. In conclusion: Acute pyelonephritis in a single kidney patient can appear as a pattern of acute renal failure with normal plasma urea levels. RESUMEN:La insuficiencia renal aguda es un sindrome que característicamente cursa con niveles plasmáticos elevados de urea y creatinina. Sin embargo, hay situaciones clínicas en las cuales este sindrome puede cursar con un incremento de la creatininemia sin presentar elevación de la uremia.En este reporte presentamos un caso clínico de una insuficiencia renal aguda con uremia normal secundaria a una pielonefritis aguda en un paciente con riñón único. El paciente presentaba una elevada excreción fraccional de urea lo cual podía explicar su uremia normal pese a estar cursando una caída del filtrado gomerular. Dicha excreción de urea elevada fue interpretada como secundaria a una diabetes insipida nefrogénica y una alteración en el recirculado intra-renal de la urea ambos producto de la pielonefritis aguda. Concluimos que la pielonefritis aguda en un paciente mono-reno puede presentarse con un patrón de insuficiencia renal aguda con uremia normal.

  20. ACUTE RENAL FAILURE WITH NORMAL PLASMA UREA LEVEL SECONDARY TO ACUTE PYELONEPHITIS IN A SINGLE KIDNEY PATIENT

    Directory of Open Access Journals (Sweden)

    Algranati L

    2007-04-01

    Full Text Available SUMMARY: Acute renal failure is a syndrome that usually runs with an increase in creatinine and urea plasma levels. However, there are clinical situations in which this syndrome may run with an increase in plasma creatinine keeping normal the urea one. In this report we present a case of acute renal failure with normal plasma urea level secondary to an acute pyelonephritis in a single kidney patient. The patient had an increased fractional excretion of urea which could explain the normal plasma urea levels found despite of his reduced glomerular filtration. This increased urea excretion state was interpreted as a consequence of the nephrogenic diabetes insipidus and alteration of the intra-renal urea reciclying process that the acute pyelonephritis induced. In conclusion: Acute pyelonephritis in a single kidney patient can appear as a pattern of acute renal failure with normal plasma urea levels.RESUMEN: La insuficiencia renal aguda es un sindrome que característicamente cursa con niveles plasmáticos elevados de urea y creatinina. Sin embargo, hay situaciones clínicas en las cuales este sindrome puede cursar con un incremento de la creatininemia sin presentar elevación de la uremia. En este reporte presentamos un caso clínico de una insuficiencia renal aguda con uremia normal secundaria a una pielonefritis aguda en un paciente con riñón único. El paciente presentaba una elevada excreción fraccional de urea lo cual podía explicar su uremia normal pese a estar cursando una caída del filtrado gomerular. Dicha excreción de urea elevada fue interpretada como secundaria a una diabetes insipida nefrogénica y una alteración en el recirculado intra-renal de la urea ambos producto de la pielonefritis aguda. Concluimos que la pielonefritis aguda en un paciente mono-reno puede presentarse con un patrón de insuficiencia renal aguda con uremia normal.

  1. Association of Irisin Plasma Levels with Anthropometric Parameters in Children with Underweight, Normal Weight, Overweight, and Obesity

    Directory of Open Access Journals (Sweden)

    Leticia Elizondo-Montemayor

    2017-01-01

    Full Text Available The correlations between irisin levels, physical activity, and anthropometric measurements have been extensively described in adults with considerable controversy, but little evidence about these relationships has been found in children. The objective of this study is to correlate the plasma levels of irisin in underweight, normal weight, overweight, and obese children with anthropometric parameters and physical activity levels. A cross-sample of 40 children was divided into the following groups on the basis of body mass index (BMI percentile. The correlations of plasma irisin levels with physical activity, anthropometric, and metabolic measurements were determined. Plasma irisin levels (ng/mL were lower for the underweight group (164.2 ± 5.95 than for the normal weight and obese groups (182.8 ± 5.58; p<0.05. Irisin levels correlated positively with BMI percentile (0.387, waist circumference (0.373, and fat-free mass (0.353; p<0.05, but not with body muscle mass (−0.027. After a multiple linear regression analysis, only BMI percentile (0.564; p<0.008 showed a positive correlation with irisin. Our results indicated no association with metabolic parameters. A negative correlation with physical activity was observed. Interrelationships among body components might influence irisin levels in children.

  2. Mandibulary dental arch form differences between level four polynomial method and pentamorphic pattern for normal occlusion sample

    Directory of Open Access Journals (Sweden)

    Y. Yuliana

    2011-07-01

    Full Text Available The aim of an orthodontic treatment is to achieve aesthetic, dental health and the surrounding tissues, occlusal functional relationship, and stability. The success of an orthodontic treatment is influenced by many factors, such as diagnosis and treatment plan. In order to do a diagnosis and a treatment plan, medical record, clinical examination, radiographic examination, extra oral and intra oral photos, as well as study model analysis are needed. The purpose of this study was to evaluate the differences in dental arch form between level four polynomial and pentamorphic arch form and to determine which one is best suitable for normal occlusion sample. This analytic comparative study was conducted at Faculty of Dentistry Universitas Padjadjaran on 13 models by comparing the dental arch form using the level four polynomial method based on mathematical calculations, the pattern of the pentamorphic arch and mandibular normal occlusion as a control. The results obtained were tested using statistical analysis T student test. The results indicate a significant difference both in the form of level four polynomial method and pentamorphic arch form when compared with mandibular normal occlusion dental arch form. Level four polynomial fits better, compare to pentamorphic arch form.

  3. High-normal levels of hs-CRP predict the development of non-alcoholic fatty liver in healthy men.

    Directory of Open Access Journals (Sweden)

    Jieun Lee

    Full Text Available We performed a follow-up study to address whether high sensitivity C-reactive protein (hs-CRP levels within the normal range can predict the development of non-alcoholic fatty liver disease (NAFLD in healthy male subjects. Among15347 male workers between 30 and 59 years old who received annual health check-ups in 2002, a NAFLD-free cohort of 4,138 was followed through December 2009. Alcohol consumption was assessed with a questionnaire. At each visit, abdominal ultrasonography was performed to identify fatty liver disease. The COX proportional hazard model was used to evaluate the relationship between hs-CRP and incident NAFLD. During the follow-up period, 28.8% (1191 of 4138 of participants developed NAFLD. The hazard ratios of NAFLD were increased by hs-CRP categories within the normal range in the non-adjusted model and age-adjusted model. After adjusting for age, exercise, smoking, BMI, systolic BP, triglyceride, and fasting glucose, these incidences were only increased between the lowest and the highest hs-CRP categories. The risk for NAFLD increased as the hs-CRP level increased (p< 0.001. As the hs-CRP level increased within the healthy cohort, the risk of developing NAFLD increased. This trend remained true even if the hs-CRP level remained within the normal range. hs-CRP can be used as a predictor of NAFLD, as well as other obesity-associated diseases. Therefore, individuals with higher hs-CRP levels (even within the normal range may require appropriate follow-up and management to prevent NAFLD development.

  4. Impact of Different Normality Thresholds for 24-hour ABPM at the Primary Health Care Level

    Directory of Open Access Journals (Sweden)

    Guilherme Brasil Grezzana

    Full Text Available Abstract Background: Hypertension is an important risk factor for cardiovascular outcomes. Primary health care (PHC physicians should be prepared to act appropriately in the prevention of cardiovascular risk factors. However, the rates of patients with control of blood pressure (BP remain low. The impact of the reclassification of high BP by 24-hour ambulatory BP monitoring (ABPM can lead to different medical decisions in PHC. Objective: To evaluate the agreement between the BP measured by a conventional method by PHC physicians and by 24-hour ABPM, considering different BP normal thresholds for the 24-hour ABPM according to the V Brazilian ABPM Guidelines and the European Society of Hypertension Guidelines. Methods: A cross-sectional study including 569 hypertensive patients. The BP was initially measured by the PHC physicians and, later, by 24-hour ABPM. The BP measurements were obtained independently between the two methods. The therapeutic targets for the conventional BP followed the guidelines by the Eighth Joint National Committee (JNC 8, the V ABPM Brazilian Guidelines, and the 2013 European Hypertension Guidelines. Results: There was an accuracy of 54.8% (95% confidence interval [95%CI] 0.51 - 0.58% for the BP measured with the conventional method when compared with the 24-hour ABPM, with a sensitivity of 85% (95%CI 80.8 - 88.6%, specificity of 31.9% (95%CI 28.7 - 34.7%, and kappa value of 0.155, when considering the European Hypertension Guidelines. When using more stringent thresholds to characterize the BP as "normal" by ABPM, the accuracy was 45% (95%CI 0.41 - 0.47% for conventional measurement when compared with 24-hour ABPM, with a sensitivity of 86.7% (95%CI 0.81 - 0.91%, specificity of 29% (95%CI 0.26 - 0.30%, and kappa value of 0.103. Conclusion: The BP measurements obtained by PHC physicians showed low accuracy when compared with those obtained by 24-hour ABPM, regardless of the threshold set by the different guidelines.

  5. Association between serum 25-hydroxyvitamin D levels and bone mineral density in normal postmenopausal women

    Directory of Open Access Journals (Sweden)

    Vasundhara Kamineni

    2016-01-01

    Full Text Available Aim: This study was conducted with the objective of assessing serum 25-hydroxyvitamin D (25(OHD in postmenopausal women (PMW, to detect osteopenia or osteoporosis in PMW and to establish a correlation between serum 25(OHD levels and bone mineral density (BMD. Materials and Methods: A total of 100 healthy PMW were selected, and a prospective observational study was conducted to correlate the BMD with serum 25(OHD levels. Their laboratory investigations along with serum 25(OHD levels were done. Their BMD was assessed with dual-energy X-ray absorptiometry at lumbar spine and neck of femur; T-scores were derived. Correlation analysis was done to investigate the relationship between serum 25(OHD levels and BMD. Results: The proportion of osteoporosis at the hip was 31.9% in deficient group, 16.1% in insufficient, and 18.2% in sufficient group and at lumbar spine, it was 27.7%, 16.1%, and 22.7%, respectively. Forty-seven percent of PMW had deficient (<20 ng/ml serum 25(OHD levels and 31% had insufficiency. T-score at hip in deficient group was −2.05 ± 0.25, and in an insufficient group, it was −1.79 ± 0.13; T-score at lumbar spine was −1.92 ± 0.12 and −1.79 ± 0.12, respectively, but both were not statistically significant. Osteoporosis was seen in 24%, osteopenia in 55% at hip level and 23% and 59% respectively at lumbar spine. There was no association between serum 25(OHD levels and BMD neither at hip nor at lumbar spine ( P = 0.51 and P = 0.79 respectively. Conclusion: In this study, among our cohort of patients there was no correlation between serum 25(OHD levels and BMD. However, Vitamin D deficiency coexists with low BMD. Vitamin D insufficiency is a common risk factor for osteoporosis associated with increased bone remodeling and low bone mass.

  6. Exercise training normalizes skeletal muscle vascular endothelial growth factor levels in patients with essential hypertension

    DEFF Research Database (Denmark)

    Hansen, Ane Håkansson; Nielsen, Jens Jung; Saltin, Bengt

    2010-01-01

    METHODS: Vascular endothelial growth factor (VEGF) protein and capillarization were determined in muscle vastus lateralis biopsy samples in individuals with essential hypertension (n = 10) and normotensive controls (n = 10). The hypertensive individuals performed exercise training for 16 weeks....... Muscle samples as well as muscle microdialysis fluid samples were obtained at rest, during and after an acute exercise bout, performed prior to and after the training period, for the determination of muscle VEGF levels, VEGF release, endothelial cell proliferative effect and capillarization. RESULTS......: Prior to training, the hypertensive individuals had 36% lower levels of VEGF protein and 22% lower capillary density in the muscle compared to controls. Training in the hypertensive group reduced (P

  7. Serum IGF1 and insulin levels in girls with normal and precocious puberty

    DEFF Research Database (Denmark)

    Sørensen, Kaspar; Aksglaede, Lise; Petersen, Jørgen Holm

    2012-01-01

    IGF1 plays an important role in growth and metabolism during puberty. IGF1 levels are increased in girls with central precocious puberty (CPP). However, the relationship with insulin before and during gonadal suppression is unknown. In addition, the influence of the exon 3-deleted GH receptor gene...

  8. Diurnal rhythm in serum levels of inhibin B in normal men

    DEFF Research Database (Denmark)

    Carlsen, E; Olsson, C; Petersen, J H

    1999-01-01

    in the early morning hours and lower values in the late afternoon and evening. We did not find evidence for a role of FSH in this diurnal variation of inhibin B. However, covariation with serum levels of testosterone and estradiol suggested that these hormones might play a role in the diurnal rhythm of inhibin...

  9. Effect of glibenclamide on insulin release at moderate and high blood glucose levels in normal man

    NARCIS (Netherlands)

    Ligtenberg, JJM; Venker, CE; Sluiter, WJ; VanHaeften, TW

    Insulin release occurs in two phases; sulphonylurea derivatives may have different potencies in stimulating first-and second-phase insulin release. We studied the effect of glibenclamide on insulin secretion at submaximally and maximally stimulating blood glucose levels with a primed hyperglycaemic

  10. Experimental Investigation of Liquid-Level Measuring Accuracy in a Low Pressure Environment

    International Nuclear Information System (INIS)

    Adamson, D.J.

    1996-10-01

    Dip Tubes which are used for determining liquid level in many processes at SRS will be used to measure the liquid level of the Am/Cm solution in the Feed Tank at the MPPF. The Feed Tank operates under a vacuum, therefore the Dip Tubes will operate under a vacuum. Uncertainty in how accurate the Dip Tubes would perform in a vacuum environment led to testing. The Am/Cm Melter Liquid-Feed Tank measurement test was mocked-up per Figure 1. The Feed Tank was designed to simulate actual conditions in which the Dip Tubes would measure the differential pressure. The Feed Tank was made of Stainless Steel with a Lexan window to view inside the tank during testing. The Feed Tank was built per Drawing SRT-ETF-DD-96008, Revision A. The accuracy of the Dip Tubes was checked first by filling the Feed Tank at a flow rate of 3.5 L/min and venting it to the atmosphere. Figure 2 shows that the Dip Tubes were responsive and accurate when compared to the data from the measuring scale on the view window. Then tests were conducted with 23y Hg vacuum inside the tank and water flow rates of 3.9 L/min, 1.8 L/min, and 0.7 L/min being fed to the tank. The data from each test are depicted in Figure 3, Figure 4, and Figure 5, respectively. The Dip Tubes responded accurately for the three test with a maximum error range of +0.31y to -0.19y when compared to the measuring scale located next to the view window on the Feed Tank

  11. Insulin and leptin levels in overweight and normal-weight Iranian adolescents: The CASPIAN-III study

    Directory of Open Access Journals (Sweden)

    Ehsan Bahrami

    2014-01-01

    Full Text Available Background: In this study, we aim to compare insulin and leptin levels in adolescents with or without excess weight and in those with or without abdominal obesity. Materials and Methods : This case-control study was conducted among 486 samples. We randomly selected 243 overweight and an equal number of normal-weight adolescents from among participants of the third survey of a national surveillance program entitled "Childhood and Adolescence Surveillance and PreventIon of Adult Non-communicable diseases study." Serum insulin and leptin were compared between two groups and their correlation was determined with other variables. Results: The mean age and body mass index (BMI of participants were 14.10 ± 2.82 years and 22.12 ± 6.49 kg/m 2 , respectively. Leptin and insulin levels were higher in overweight than in normal-weight adolescents (P < 0.05. Leptin level was higher in children with abdominal obesity than in their other counterparts (P < 0.001. Leptin level was correlated with age, fasting blood glucose, BMI, and insulin level. Conclusion: Insulin and leptin levels were higher among overweight and obese children, which may reflect insulin and leptin-resistance. Given the complications of excess weight from early life, prevention and controlling childhood obesity should be considered as a health priority.

  12. Signatures of Majorana Kramers pairs in superconductor-Luttinger liquid and superconductor-quantum dot-normal lead junctions

    DEFF Research Database (Denmark)

    Kim, Younghyun; Liu, Dong E.; Gaidamauskas, Erikas

    2016-01-01

    Time-reversal invariant topological superconductors are characterized by the presence of Majorana Kramers pairs localized at defects. One of the transport signatures of Majorana Kramers pairs is the quantized differential conductance of $4e^2/h$ when such a one-dimensional superconductor is coupled...... to that in a spin-triplet superconductor - normal lead junction. We also study here a quantum dot coupled to a normal lead and a Majorana Kramers pair and investigate the effect of local repulsive interactions leading to an interplay between Kondo and Majorana correlations. Using a combination of renormalization...... sector of the topological superconductor. We investigate the stability of the Majorana phase with respect to Gaussian fluctuations....

  13. Aspirin effects on lymphocyte cyclic AMP levels in normal human subjects.

    Science.gov (United States)

    Snider, D E; Parker, C W

    1976-01-01

    In purified lymphocytes from the peripheral blood of healthy human subjects who had ingested therapeutic doses of aspirin, there was a significant decrease in resting cyclic AMP levels as well as a partial inhibition of the rise in cyclic AMP with isoproterenol or prostaglandin E1. These changes were seen as early as 30 min after aspirin ingestion and did not appear to result from aspirin effects on lymphocyte recovery, purity, viability, or relative number of thymus- or bone marrow-derived lymphocytes. In contrast, the direct addition of aspirin to suspensions of purified peripheral lymphocytes did not significantly alter their cyclic AMP levels. However, an effect of aspirin could be obtained in vitro if aspirin was added to unprocessed whole blood during the dextran sedimentation phase of the cell purification. Thus the effect of aspirin on lymphocyte cyclic AMP metabolism, may be indirect, through other cells present in the peripheral blood. PMID:182720

  14. On-Site Decontamination System for Liquid Low Level Radioactive Waste - 13010

    Energy Technology Data Exchange (ETDEWEB)

    OSMANLIOGLU, Ahmet Erdal [Cekmece Nuclear Research and Training Center, Kucukcekmece Istanbul (Turkey)

    2013-07-01

    This study is based on an evaluation of purification methods for liquid low-level radioactive waste (LLLW) by using natural zeolite. Generally the volume of liquid low-level waste is relatively large and the specific activity is rather low when compared to other radioactive waste types. In this study, a pilot scale column was used with natural zeolite as an ion exchanger media. Decontamination and minimization of LLLW especially at the generation site decrease operational cost in waste management operations. Portable pilot scale column was constructed for decontamination of LLW on site. Effect of temperature on the radionuclide adsorption of the zeolite was determined to optimize the waste solution temperature for the plant scale operations. In addition, effect of pH on the radionuclide uptake of the zeolite column was determined to optimize the waste solution pH for the plant scale operations. The advantages of this method used for the processing of LLLW are discussed in this paper. (authors)

  15. Evaporation studies on Oak Ridge National Laboratory liquid low-level waste

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, V.L. [PAI Corp., Oak Ridge, TN (United States); Perona, J.J. [Oak Ridge National Lab., TN (United States)

    1993-03-01

    Evaporation studies were performed with Melton Valley storage tank liquid low-level radioactive waste concentrate and with surrogates (nonradioactive) to determine the feasibility of a proposed out-of-tank-evaporation project. Bench-scale tests indicated that volume reductions ranging from 30 to 55% could be attained. Vendor-site tests were conducted (with surrogate waste forms) using a bench-scale single-stage, low-pressure (subatmospheric), low-temperature (120 to 173{degree}F) evaporator similar to units in operation at several nuclear facilities. Vendor tests were successful; a 30% volume reduction was attained with no crystallization of solids and no foaming, as would be expected from a high pH solution. No fouling of the heat exchanger surfaces occurred during these tests. It is projected that 52,000 to 120,000 gal of water could be evaporated from the supernate stored in the Melton and Bethel Valley liquid low-level radioactive waste (LLLW) storage tanks with this type of evaporator.

  16. Excitation of high energy levels under laser exposure of suspensions of nanoparticles in liquids

    Energy Technology Data Exchange (ETDEWEB)

    Shafeev, G.A. [Wave Research Center of A.M. Prokhorov General Physics Institute, 38, Vavilov Street, 119991 Moscow (Russian Federation)], E-mail: shafeev@kapella.gpi.ru; Simakin, A.V. [Wave Research Center of A.M. Prokhorov General Physics Institute, 38, Vavilov Street, 119991 Moscow (Russian Federation); Bozon-Verduraz, F. [ITODYS, UMR CNRS 7086, Universite Paris 7-Denis Diderot, 2, place Jussieu, 75251 Paris cedex 05 (France); Robert, M. [Laboratoire d' Electrochimie Moleculaire, UMR CNRS 7591, Universite Paris 7 Denis Diderot, 2, place Jussieu, 75251 Paris cedex 05 (France)

    2007-12-15

    Laser exposure of suspensions of nanoparticles in liquids leads to excitation of high energy levels in both liquid and nanoparticle material. The emission spectrum of the colloidal solution under exposure of a suspension metallic nanoparticles in water to radiation of a Nd:YAG laser of a picosecond range of pulse duration is discussed. Excitation of nuclear energy levels and neutron release is experimentally studied on the model system of transmutation of Hg into Au that occurs under exposure of Hg nanodrops suspended in D{sub 2}O. The proposed mechanism involves: (i) emission of X-ray photons by Hg nanoparticles upon laser exposure, leading to neutron release from D{sub 2}O, (ii) initiation of Hg {yields} Au transmutation by the capture of neutrons. The effect of transmutation is more pronounced using {sup 196}Hg isotope instead of Hg of natural isotope composition. The influence of laser pulse duration on the degree of transmutation (from fs through ns range) is discussed.

  17. Impact of Different Normality Thresholds for 24-hour ABPM at the Primary Health Care Level.

    Science.gov (United States)

    Grezzana, Guilherme Brasil; Moraes, David William; Stein, Airton Tetelbon; Pellanda, Lucia Campos

    2017-02-01

    Hypertension is an important risk factor for cardiovascular outcomes. Primary health care (PHC) physicians should be prepared to act appropriately in the prevention of cardiovascular risk factors. However, the rates of patients with control of blood pressure (BP) remain low. The impact of the reclassification of high BP by 24-hour ambulatory BP monitoring (ABPM) can lead to different medical decisions in PHC. To evaluate the agreement between the BP measured by a conventional method by PHC physicians and by 24-hour ABPM, considering different BP normal thresholds for the 24-hour ABPM according to the V Brazilian ABPM Guidelines and the European Society of Hypertension Guidelines. A cross-sectional study including 569 hypertensive patients. The BP was initially measured by the PHC physicians and, later, by 24-hour ABPM. The BP measurements were obtained independently between the two methods. The therapeutic targets for the conventional BP followed the guidelines by the Eighth Joint National Committee (JNC 8), the V ABPM Brazilian Guidelines, and the 2013 European Hypertension Guidelines. There was an accuracy of 54.8% (95% confidence interval [95%CI] 0.51 - 0.58%) for the BP measured with the conventional method when compared with the 24-hour ABPM, with a sensitivity of 85% (95%CI 80.8 - 88.6%), specificity of 31.9% (95%CI 28.7 - 34.7%), and kappa value of 0.155, when considering the European Hypertension Guidelines. When using more stringent thresholds to characterize the BP as "normal" by ABPM, the accuracy was 45% (95%CI 0.41 - 0.47%) for conventional measurement when compared with 24-hour ABPM, with a sensitivity of 86.7% (95%CI 0.81 - 0.91%), specificity of 29% (95%CI 0.26 - 0.30%), and kappa value of 0.103. The BP measurements obtained by PHC physicians showed low accuracy when compared with those obtained by 24-hour ABPM, regardless of the threshold set by the different guidelines. A hipertensão arterial sistêmica é um fator de risco importante para

  18. Effect of low to normal dietary phosphorus levels on zinc metabolism and tissue distribution in calves

    International Nuclear Information System (INIS)

    Laflamme, D.P.; Miller, W.J.; Neathery, M.W.; Gentry, R.P.; Blackmon, D.M.; Logner, K.R.; Fielding, A.S.

    1985-01-01

    Sixteen 10-wk-old, phosphorus (P)-depleted Holstein bull calves were fed for 6 wk a control diet containing .08% P or P-supplemented diets containing .14, .20 or .32% P with supplemental P from two sources (CDP and Dynafos). The diets contained .45, .56, .66 and .87% Ca. After 5 wk of the experiment, the calves were dosed orally with 65 Zn, and daily total fecal collections were initiated. At the end of the experimental period, the calves were killed and tissue samples were taken for total Zn and 65 Zn analyses. Growth, feed intake and feed efficiency improved with increasing dietary P levels. Level of dietary P and Ca had little or no effect on total Zn content of rib, tibia, liver, heart, kidney, muscle or blood. Likewise, 65 Zn absorption and content in most tissues were not affected. The results do not preclude the possibility of some minor effects of P levels on Zn metabolism. However, it is apparent that when adequate Zn is fed, any effects are likely to be of little or no practical importance

  19. Tinnitus is associated with reduced sound level tolerance in adolescents with normal audiograms and otoacoustic emissions

    Science.gov (United States)

    Sanchez, Tanit Ganz; Moraes, Fernanda; Casseb, Juliana; Cota, Jaci; Freire, Katya; Roberts, Larry E.

    2016-01-01

    Recent neuroscience research suggests that tinnitus may reflect synaptic loss in the cochlea that does not express in the audiogram but leads to neural changes in auditory pathways that reduce sound level tolerance (SLT). Adolescents (N = 170) completed a questionnaire addressing their prior experience with tinnitus, potentially risky listening habits, and sensitivity to ordinary sounds, followed by psychoacoustic measurements in a sound booth. Among all adolescents 54.7% reported by questionnaire that they had previously experienced tinnitus, while 28.8% heard tinnitus in the booth. Psychoacoustic properties of tinnitus measured in the sound booth corresponded with those of chronic adult tinnitus sufferers. Neither hearing thresholds (≤15 dB HL to 16 kHz) nor otoacoustic emissions discriminated between adolescents reporting or not reporting tinnitus in the sound booth, but loudness discomfort levels (a psychoacoustic measure of SLT) did so, averaging 11.3 dB lower in adolescents experiencing tinnitus in the acoustic chamber. Although risky listening habits were near universal, the teenagers experiencing tinnitus and reduced SLT tended to be more protective of their hearing. Tinnitus and reduced SLT could be early indications of a vulnerability to hidden synaptic injury that is prevalent among adolescents and expressed following exposure to high level environmental sounds. PMID:27265722

  20. Simultaneous 13C/14C dual isotope breath test measurement of gastric emptying of solid and liquid in normal subjects and patients: comparison with scintigraphy

    International Nuclear Information System (INIS)

    Chew, C. G.; Bartholomeusz, F.D.L.; Bellon, M.; Chatterton, B. E.

    2003-01-01

    To develop a simple method for simultaneous solid and liquid gastric emptying assessment using a dual isotope labelled breath test. 13 patients were given 100 g ground beef labelled with 25 MBq 99m Tc sulphur colloid and 74 KBq 14 C octanoic acid, and 150 ml 10% glucose drink labelled with 8 MBq 67 Ga citrate and 150 mg 13 C acetate. 10 normal volunteers were given the same test meals but labelled with 14 C and 13 C only. Breath was collected at baseline and regularly for 4 hours. The 14 CO 2 and 13 CO 2 activity was measured with liquid scintillation counting and mass spectroscopy. The times to maximum 14 CO 2 and 13 CO 2 , were determined. Comparison was made between times to maximum 14 CO 2 with scintigraphic retention of 99m Tc at 100 minutes and times to maximum 13 CO 2 with the scintigraphic half-clearance time of 67 Ga. For the solid meal, the times to maximum 14 CO 2 were: 60-120 minutes in the 8 patients with normal gastric emptying of 99m Tc; 75-145 minutes for the 10 healthy volunteers; 75-180 minutes for the remaining 5 patients with abnormal gastric emptying of 99m Tc. There was a weak but significant correlation (r = 0.56, p 14 CO 2 and gastric retention of 99m Tc at 100 minutes. For the liquid meal, times to maximum 13 CO 2 were: 20-35 minutes for the 4 with normal gastric emptying of 67 Ga; 15-40 minutes for the 10 healthy volunteers; 20-75 minutes for the remaining 9 patients with abnormal gastric emptying of 67 Ga. There was a strong and significant correlation (r = 0.88, p 13 CO 2 and gastric half-clearance time of 67 Ga. Breath tests utilising test meals labelled with *C isotopes are valid alternatives to scintigraphic studies using 99m Tc and 67 Ga for the simultaneous assessment of gastric emptying of solids and liquids. (author)

  1. Comparison of Different Levels of Reading Comprehension between Hearing-Impaired Loss and Normal-Hearing Students

    Directory of Open Access Journals (Sweden)

    Azam Sharifi

    2011-12-01

    Full Text Available Background and Aim: Reading skill is one of the most important necessities of students' learning in everyday life. This skill is referred to the ability of comprehension, comment and conclusion from texts and receiving the meaning of the massage which is composed. Educational development in any student has a direct relation with the ability of the comprehension. This study is designed to investigate the effects of hearing loss on reading comprehension in hearing-impaired students compared to normal-hearing ones.Methods: Seventeen hearing-impaired students in 4th year of primary exceptional schools in Karaj, Robatkarim and Shahriyar, Iran, were enrolled in this cross-sectional study. Seventeen normal-hearing students were randomly selected from ordinary schools next to exceptional ones as control group. They were compared for different levels of reading comprehension using the international standard booklet (PIRLS 2001. Results: There was a significant difference in performance between hearing-impaired and normal- hearing students in different levels of reading comprehension (p<0.05.Conclusion: Hearing loss has negative effects on different levels of reading comprehension, so in exceptional centers, reconsideration in educational planning in order to direct education from memorizing to comprehension and deeper layers of learning seems necessary.

  2. Effect of aluminum chloride on blood glucose level and lipid profile in normal, diabetic and treated diabetic rats.

    Science.gov (United States)

    Konda, Venugopala Rao; Eerike, Madhavi; Chary, R Prasanth; Arunachalam, Ruckmani; Yeddula, Venkata Ramana; Meti, Vinayak; Devi, T Sobita

    2017-01-01

    The objectives of the study were to assess evaluate the effects of aluminum chloride (AlCl 3 ) on blood glucose and lipid levels in normal, diabetic, and glibenclamide-treated diabetic rats. Forty-two male Wistar rats were divided into seven groups of six each. Group I was normal control, Groups II and III were given AlCl 3 50 and 100 mg/kg, and Group IV to VII were administered with streptozotocin (STZ) (60 mg/kg) intraperitoneally. Group IV was diabetic control, Group V in addition was given AlCl 3 50 mg/kg, Group VI glibenclamide (10 mg/kg), and Group VII glibenclamide and AlCl 3 (50 mg/kg) per-oral daily for 28 days. Blood glucose and lipid levels were estimated at base line, after diabetes was set in and on the last day of study. Histopathological changes in pancreas, liver, and kidney were studied. No significant change was observed in blood glucose and lipid levels in Group I. Group II and III showed a dose-dependent significant increase in blood glucose was observed. Group V had a reduction in blood glucose but not to the nondiabetic level. Group VI had significant reduction in blood sugar. In Group VII, treated with glibenclamide and AlCl 3 , there was no significant change in blood glucose reduction compared to Group VI. Lipid levels were reduced in groups treated with AlCl 3 and glibenclamide and not in other groups. Gross tissue damage was seen in pancreas in STZ group and in liver and kidney in AlCl 3 groups. AlCl 3 administration in Wistar rats caused in significant hyperglycemia in normal rats, hypoglycemia in diabetic rats, and did not influenced hypoglycemic effect of glibenclamide and in addition, resulted in reduction in lipid levels.

  3. Seismic evaluation of existing liquid low level waste system at the Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Hammond, C.R.; Holmes, R.M.; Kincaid, J.H.; Singhal, M.K.; Stockdale, B.I.; Walls, J.C.; Webb, D.S.

    1993-01-01

    The existing liquid low level waste (LLLW) system at the Oak Ridge National Laboratory is used to collect, neutralize, concentrate, and store the radioactive and toxic waste from various sources at the Laboratory. The waste solutions are discharged from source facilities to individual collection tanks, transferred by underground piping to an evaporator facility for concentration, and pumped through the underground piping to storage in underground tanks. The existing LLLW system was installed in the 1950s with several system additions up to the present. The worst-case accident postulated is an earthquake of sufficient magnitude to rupture the tanks and/or piping so as to damage the containment integrity to the surrounding soil and environment. The objective of an analysis of the system is to provide a level of confidence in the seismic resistance of the LLLW system to withstand the postulated earthquake

  4. Measurement of gross beta radioactivity in high-level liquid waste

    International Nuclear Information System (INIS)

    Lu Feng; Lin Cansheng; Zhang Xianzi; Chen Guoan; Zhang Chonghai

    1992-01-01

    Using beta plastic scintillation counter of low level background, gross beta radioactivity of twelve samples for high-level liquid waste is determined directly. Beta efficiency curves of plastic scintillation counter for four mass thickness are calibrated in advance. Determining gross beta radioactivity, gross efficiency of the scintillation counter for various energy beta ray is calculated via weighted mean method with the ratio of radioactivity for each nuclide. The ratio of radioactivity for nuclides which have gamma disintegration is determined in terms of the radioactivity measured by gamma spectrometer. The ratio of the radioactivity for 90 Sr which has purity beta disintegration is calculated in terms of half life time approximation. The ratio of the radioactivity for 147 Pm which also has purity disintegration is calculated by means of apparent cooling-time approximation. The uncertainty of results for the present work is about +-15%

  5. Solidification of low-level radioactive liquid waste using a cement-silicate process

    International Nuclear Information System (INIS)

    Grandlund, R.W.; Hayes, J.F.

    1979-01-01

    Extensive use has been made of silicate and Portland cement for the solidification of industrial waste and recently this method has been successfully used to solidify a variety of low level radioactive wastes. The types of wastes processed to date include fuel fabrication sludges, power reactor waste, decontamination solution, and university laboratory waste. The cement-silicate process produces a stable solid with a minimal increase in volume and the chemicals are relatively inexpensive and readily available. The method is adaptable to either batch or continuous processing and the equipment is simple. The solid has leaching characteristics similar to or better than plain Portland cement mixtures and the leaching can be further reduced by the use of ion-exchange additives. The cement-silicate process has been used to solidify waste containing high levels of boric acid, oils, and organic solvents. The experience of handling the various types of liquid waste with a cement-silicate system is described

  6. Detection of environmental radioactive contamination levels using a liquid-scintillation counter

    International Nuclear Information System (INIS)

    Calisto, W.; Kun, A.; Campos, E.

    1981-01-01

    A high-efficiency LS-100 C liquid scintillation counter was used to detect low levels of environmental activity. Different concentrations of primary scintillator were tested and these established the most suitable values. Work was carried out at the same time to find conditions which would ensure a low background and high efficiency. To reduce the sample volume used, various types of chelating agents were utilized: 8-hydroxyquinoline (oxine), tannic acid, cupferron, dimethylglioxime and beta-naphthol. These were tested at pH levels of 1, 6 and 11. Measurements were performed by means of the Cerenkov effect using substances with differing refraction indices - 26% sodium chloride, water, glycerine, carbon bisulphide, nitrobenzene, benzyl alcohol and toluene. Finally, work was done on comparing spectra obtained by Cerenkov radiation and by 90 Sr and 90 Y beta radiation respectively. Clearly differentiated zones were obtained, thus making it possible to distinguish one isotope from another in an equilibrium solution. (author)

  7. Contaminant transport modelling in tidal influenced water body for low level liquid waste discharge out

    International Nuclear Information System (INIS)

    Singh, Sanjay; Naidu, Velamala Simhadri

    2018-01-01

    Low level liquid waste is generated from nuclear reactor operation and reprocessing of spent fuel. This waste is discharged into the water body after removing bulk of its radioactivity. Dispersion of contaminant mainly depends on location of outfall and hydrodynamics of water body. For radiological impact assessment, in most of the analytical formulations, source term is taken as continuous release. However, this may not be always true as the water level is influenced by tidal movement and the selected outfall may come under intertidal zone in due course of the tidal cycle. To understand these phenomena, a case study has been carried out to evaluate hydrodynamic characteristics and dilution potential of outfall located in inter-tidal zone using numerical modelling

  8. Serum Levels of Acyl-Carnitines along the Continuum from Normal to Alzheimer's Dementia.

    Directory of Open Access Journals (Sweden)

    Adriana Cristofano

    Full Text Available This study aimed to determine the serum levels of free L-carnitine, acetyl-L-carnitine and 34 acyl-L-carnitine in healthy subjects and in patients with or at risk of Alzheimer's disease. Twenty-nine patients with probable Alzheimer's disease, 18 with mild cognitive impairment of the amnestic type, 24 with subjective memory complaint and 46 healthy subjects were enrolled in the study, and the levels of carnitine and acyl-carnitines were measured by tandem mass spectrometry. The concentrations of acetyl-L-carnitine progressively decreased passing from healthy subjects group (mean±SD, 5.6±1.3 μmol/L to subjective memory complaint (4.3±0.9 μmol/L, mild cognitive impairment (4.0±0.53 μmol/L, up to Alzheimer's disease (3.5±0.6 μmol/L group (p<0.001. The differences were significant for the comparisons: healthy subjects vs. subjective memory complaint, mild cognitive impairment or Alzheimer's disease group; and subjective memory complaint vs. Alzheimer's disease group. Other acyl-carnitines, such as malonyl-, 3-hydroxyisovaleryl-, hexenoyl-, decanoyl-, dodecanoyl-, dodecenoyl-, myristoyl-, tetradecenoyl-, hexadecenoyl-, stearoyl-, oleyl- and linoleyl-L-carnitine, showed a similar decreasing trend, passing from healthy subjects to patients at risk of or with Alzheimer's disease. These results suggest that serum acetyl-L-carnitine and other acyl-L-carnitine levels decrease along the continuum from healthy subjects to subjective memory complaint and mild cognitive impairment subjects, up to patients with Alzheimer's disease, and that the metabolism of some acyl-carnitines is finely connected among them. These findings also suggest that the serum levels of acetyl-L-carnitine and other acyl-L-carnitines could help to identify the patients before the phenotype conversion to Alzheimer's disease and the patients who would benefit from the treatment with acetyl-L-carnitine. However, further validation on a larger number of samples in a longitudinal

  9. Serum Levels of Acyl-Carnitines along the Continuum from Normal to Alzheimer's Dementia

    Science.gov (United States)

    Sapere, Nadia; La Marca, Giancarlo; Angiolillo, Antonella; Vitale, Michela; Corbi, Graziamaria; Scapagnini, Giovanni; Intrieri, Mariano; Russo, Claudio

    2016-01-01

    This study aimed to determine the serum levels of free L-carnitine, acetyl-L-carnitine and 34 acyl-L-carnitine in healthy subjects and in patients with or at risk of Alzheimer’s disease. Twenty-nine patients with probable Alzheimer’s disease, 18 with mild cognitive impairment of the amnestic type, 24 with subjective memory complaint and 46 healthy subjects were enrolled in the study, and the levels of carnitine and acyl-carnitines were measured by tandem mass spectrometry. The concentrations of acetyl-L-carnitine progressively decreased passing from healthy subjects group (mean±SD, 5.6±1.3 μmol/L) to subjective memory complaint (4.3±0.9 μmol/L), mild cognitive impairment (4.0±0.53 μmol/L), up to Alzheimer’s disease (3.5±0.6 μmol/L) group (p<0.001). The differences were significant for the comparisons: healthy subjects vs. subjective memory complaint, mild cognitive impairment or Alzheimer’s disease group; and subjective memory complaint vs. Alzheimer’s disease group. Other acyl-carnitines, such as malonyl-, 3-hydroxyisovaleryl-, hexenoyl-, decanoyl-, dodecanoyl-, dodecenoyl-, myristoyl-, tetradecenoyl-, hexadecenoyl-, stearoyl-, oleyl- and linoleyl-L-carnitine, showed a similar decreasing trend, passing from healthy subjects to patients at risk of or with Alzheimer’s disease. These results suggest that serum acetyl-L-carnitine and other acyl-L-carnitine levels decrease along the continuum from healthy subjects to subjective memory complaint and mild cognitive impairment subjects, up to patients with Alzheimer’s disease, and that the metabolism of some acyl-carnitines is finely connected among them. These findings also suggest that the serum levels of acetyl-L-carnitine and other acyl-L-carnitines could help to identify the patients before the phenotype conversion to Alzheimer’s disease and the patients who would benefit from the treatment with acetyl-L-carnitine. However, further validation on a larger number of samples in a longitudinal

  10. High Mutation Levels are Compatible with Normal Embryonic Development in Mlh1-Deficient Mice.

    Science.gov (United States)

    Fan, Xiaoyan; Li, Yan; Zhang, Yulong; Sang, Meixiang; Cai, Jianhui; Li, Qiaoxia; Ozaki, Toshinori; Ono, Tetsuya; He, Dongwei

    2016-10-01

    To elucidate the role of the mismatch repair gene Mlh1 in genome instability during the fetal stage, spontaneous mutations were studied in Mlh1-deficient lacZ-transgenic mouse fetuses. Mutation levels were high at 9.5 days post coitum (dpc) and gradually increased during the embryonic stage, after which they remained unchanged. In addition, mutations that were found in brain, liver, spleen, small intestine and thymus showed similar levels and no statistically significant difference was found. The molecular nature of mutations at 12.5 dpc in fetuses of Mlh1 +/+ and Mlh1 -/- mice showed their own unique spectra, suggesting that deletion mutations were the main causes in the deficiency of the Mlh1 gene. Of note, fetuses of irradiated mice exhibited marked differences such as post-implantation loss and Mendelian distribution. Collectively, these results strongly suggest that high mutation ofMlh1 -/- -deficient fetuses has little effect on the fetuses during their early developmental stages, whereas Mlh1 -/- -deficient fetuses from X-ray irradiated mothers are clearly effected.

  11. Major congenital malformations in the high and normal level radiation areas of southwest coast of Kerala

    International Nuclear Information System (INIS)

    Sudheer, K.R.; Jaikrishan, G.; Andrews, V.J.; Koya, P.K.M.; Seshadri, M.; Jagadeesan, C.K.; Madhusoodhanan, M.

    2012-01-01

    Congenital malformations are defects in organogenesis during the fetal periods and its influence on the individual may vary according to the type of malformation. Some congenital malformations are trivial and may not have any significance but for a minimal cosmetic deformity. Major malformations on the contrary may be severe enough to be life-threatening with serious structural, functional or cosmetic disability requiring surgical or medical management and are an important cause of mortality and morbidity all over the world. The present paper analyses the major malformations detected during the monitoring of newborns in selected government hospitals in and around the high level natural radiation areas of Kerala, a narrow strip of land in the southwest coast extending from Purakkad panchayat of Alapuzha district in the north to Neendakara Panchayat of Quilon district in the south. The coastal area has natural deposits of Monazite sand containing Thorium. Thorium together with its daughter products accounts for the elevated levels of natural radiation. The finding in general was in conformity with similar works on malformations

  12. Plasma, salivary and urinary cortisol levels following physiological and stress doses of hydrocortisone in normal volunteers.

    Science.gov (United States)

    Jung, Caroline; Greco, Santo; Nguyen, Hanh H T; Ho, Jui T; Lewis, John G; Torpy, David J; Inder, Warrick J

    2014-11-26

    Glucocorticoid replacement is essential in patients with primary and secondary adrenal insufficiency, but many patients remain on higher than recommended dose regimens. There is no uniformly accepted method to monitor the dose in individual patients. We have compared cortisol concentrations in plasma, saliva and urine achieved following "physiological" and "stress" doses of hydrocortisone as potential methods for monitoring glucocorticoid replacement. Cortisol profiles were measured in plasma, saliva and urine following "physiological" (20 mg oral) or "stress" (50 mg intravenous) doses of hydrocortisone in dexamethasone-suppressed healthy subjects (8 in each group), compared to endogenous cortisol levels (12 subjects). Total plasma cortisol was measured half-hourly, and salivary cortisol and urinary cortisol:creatinine ratio were measured hourly from time 0 (between 0830 and 0900) to 5 h. Endogenous plasma corticosteroid-binding globulin (CBG) levels were measured at time 0 and 5 h, and hourly from time 0 to 5 h following administration of oral or intravenous hydrocortisone. Plasma free cortisol was calculated using Coolens' equation. Plasma, salivary and urine cortisol at 2 h after oral hydrocortisone gave a good indication of peak cortisol concentrations, which were uniformly supraphysiological. Intravenous hydrocortisone administration achieved very high 30 minute cortisol concentrations. Total plasma cortisol correlated significantly with both saliva and urine cortisol after oral and intravenous hydrocortisone (P cortisol and urinary cortisol:creatinine ratio may provide useful alternatives to plasma cortisol measurements to monitor replacement doses in hypoadrenal patients.

  13. Association of Tumor Growth Factor-β and Interferon-γ Serum Levels With Insulin Resistance in Normal Pregnancy.

    Science.gov (United States)

    Sotoodeh Jahromi, Abdolreza; Sanie, Mohammad Sadegh; Yusefi, Alireza; Zabetian, Hassan; Zareian, Parvin; Hakimelahi, Hossein; Madani, Abdolhossien; Hojjat-Farsangi, Mohammad

    2015-09-28

    Pregnancy is related to change in glucose metabolism and insulin production. The aim of our study was to determine the association of serum IFN-γ and TGF- β levels with insulin resistance during normal pregnancy. This cross sectional study was carried out on 97 healthy pregnant (in different trimesters) and 28 healthy non-pregnant women. Serum TGF-β and IFN- γ level were measured by ELISA method. Pregnant women had high level TGF-β and low level IFN-γ as compared non-pregnant women. Maternal serum TGF-β concentration significantly increased in third trimester as compared first and second trimester of pregnancy. Maternal serum IFN-γ concentration significantly decreased in third trimester as compared first and second trimester of pregnancy. Pregnant women exhibited higher score of HOMA IR as compared non-pregnant women. There were association between gestational age with body mass index (r=0.28, P=0.005), TGF-β (r=0.45, PInsulin resistance and TGF-β (r=0.17, p=0.05). Our findings suggest that changes in maternal cytokine level in healthy pregnant women were anti-inflammatory. Furthermore, Tumor Growth Factor-β appears has a role in induction insulin resistance in healthy pregnant women. However, further studies needed to evaluate role of different cytokines on insulin resistance in normal pregnancy.

  14. An optical liquid level sensor based on core-offset fusion splicing method using polarization-maintaining fiber

    Science.gov (United States)

    Lou, Weimin; Chen, Debao; Shen, Changyu; Lu, Yanfang; Liu, Huanan; Wei, Jian

    2016-01-01

    A simple liquid level sensor using a small piece of hydrofluoric acid (HF) etched polarization maintaining fiber (PMF), with SMF-PMF-SMF fiber structure based on Mach- Zehnder interference (MZI) mechanism is proposed. The core-offset fusion splicing method induced cladding modes interfere with the core mode. Moreover, the changing liquid level would influence the optical path difference of the MZI since the effective refractive indices of the air and the liquid is different. Both the variations of the wavelength shifts and power intensity attenuation corresponding to the liquid level can be obtained with a sensitivity of 0.4956nm/mm and 0.2204dB/mm, respectively.

  15. A comparison study of lipid profile levels between skin tags affected people and normal population in Tehran, Iran

    Directory of Open Access Journals (Sweden)

    Abbas Rasi

    2014-01-01

    Full Text Available Background: For many years the association of skin tags and endocrynopathies has been postulated, although many reports are available but it has never been evaluated to mean normal population. Dyslipidemia is a frequent disorder among people and seemed to be necessary for screening within skin tag condition. This study is designed to find any possible association between skin tags and dyslipidemia. Materials and Methods: From April 2009 to June 2011, 168 patients enrolled the study. Among the remaining 152 patients, there were 89 females (58.5% and 63 males (%41.5. Based on the TLGS study 136 men and 220 women enrolled the control group of study. The mean age was 28.4 years. Patients trained to have normal free diet for at least 1 month then referred to the laboratory. Blood samples were taken over 12 hours fasting with 2 hours intervals. Hypertriglyceridemia was defined as plasma level ≥160 mg/dl for men and ≥130 mg/dl for women. Hypercholesterolemia pointed at its value >200 mg/dl. Normal HDL levels was defined as >39 mg/dl for men and >35 mg/dl to women. Results: Mean skin tag number was 12.6 per subject. The most frequent localizations of skin tags were neck and upper chest (mean number: 13.4, 48.9% followed by axilla (mean number: 11.6, 33% and breast (10.2, 10.1% in the patient group. The mean cholesterol level of case group was 192.2 ± 33.1 mg/dl, while it was 187.0 ± 42 mg/dl in the control group. The mean ± SD for triglyceride was 132.1 ± 69 mg/dl in comparison to 129 ± 74 in the control group. Conclusion: The study showed no significant differences between normal population and patients′ lipid profile.

  16. TBP 20% - diluent/HNO3/H2O liquid-liquid extraction system: equilibrium normalization data of nitric acid, ruthenium and zirconium

    International Nuclear Information System (INIS)

    Oliveira, C.A.L.G. de.

    1984-01-01

    The extraction behaviour of nitric acid, nitrosyl-ruthenium nitrate and zirconium hydroxide nitrate in the system tri-n-butyl phosphate (TBP) 20% - diluent was studied. The main purpose was to obtain enough data to elaborate process flowsheets for the treatment of irradiated uranium fuels. During the runs, the equilibrium diagrams of nitric acid, ruthenium and zirconium were settled. From the achieved data, the influence of nitric acid, ruthenium, zirconium and nitrate ions concentration in the aqueous phase was checked. Furthermore, the density and the surface tension of the aqueous and organic phases were determined, gathering the interfacial tension after the contact between the phases. A comparison among the obtained equilibrium data and the existing one from literature allowed the elaboration of mathematical models to express the distribution behaviour of nitric acid, ruthenium and zirconium as a function of nitrate ions concentration in the aqueous phase. The reduction of TBP concentration from 30% v/v (normally used) to 20% v/v, has shown no influence in the extraction behaviour of the elements. A decreasing in the distribution values was observed and that means an important factor during the decontamination of uranium from its contaminants, ruthenium and zirconium. (Author) [pt

  17. Maternal blood total oxypurines and erythrocyte 2,3-diphosphoglycerate levels during normal pregnancy.

    Science.gov (United States)

    Mizutani, S; Akiyama, H; Kurauchi, O; Taira, H; Yamada, R; Narita, O; Tomoda, Y

    1985-01-01

    The effects of pregnancy on the levels of maternal plasma total oxypurines (hypoxanthine, xanthine and uric acid) and erythrocyte 2,3-diphosphoglycerate (2,3-DPG) was investigated. With advancing gestation there was a slight increasing tendency in plasma total oxypurines as well as erythrocyte 2,3-DPG in pregnant women. When the ratio of 2,3-DPG to total oxypurines was calculated, the ratio was almost unchanged until week 34. After week 35, the ratio decreased to week 37; the ratios between week 37 and 40 had similar values to cord blood. The above data suggest that the changes of these metabolites in maternal peripheral blood may be indicative for hypoxia with fetoplacental tissue.

  18. Return to normal streamflows and water levels: summary of hydrologic conditions in Georgia, 2013

    Science.gov (United States)

    Knaak, Andrew E.; Caslow, Kerry; Peck, Michael F.

    2015-01-01

    The U.S. Geological Survey (USGS) South Atlantic Water Science Center (SAWSC) Georgia office, in cooperation with local, State, and other Federal agencies, maintains a long-term hydrologic monitoring network of more than 340 real-time continuous-record streamflow-gaging stations (streamgages), including 10 real-time lake-level monitoring stations, 67 real-time surface-water-quality monitors, and several water-quality sampling programs. Additionally, the SAWSC Georgia office operates more than 180 groundwater monitoring wells, 39 of which are real-time. The wide-ranging coverage of streamflow, reservoir, and groundwater monitoring sites allows for a comprehensive view of hydrologic conditions across the State. One of the many benefits of this monitoring network is that the analyses of the data provide a spatially distributed overview of the hydrologic conditions of creeks, rivers, reservoirs, and aquifers in Georgia.

  19. Differentiation of isomeric N-glycan structures by normal-phase liquid chromatography-MALDI-TOF/TOF tandem mass spectrometry.

    Science.gov (United States)

    Maslen, Sarah; Sadowski, Pawel; Adam, Alex; Lilley, Kathryn; Stephens, Elaine

    2006-12-15

    The detailed characterization of protein N-glycosylation is very demanding given the many different glycoforms and structural isomers that can exist on glycoproteins. Here we report a fast and sensitive method for the extensive structure elucidation of reducing-end labeled N-glycan mixtures using a combination of capillary normal-phase HPLC coupled off-line to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) and TOF/TOF-MS/MS. Using this method, isobaric N-glycans released from honey bee phospholipase A2 and Arabidopsis thaliana glycoproteins were separated by normal-phase chromatography and subsequently identified by key fragment ions in the MALDI-TOF/TOF tandem mass spectra. In addition, linkage and branching information were provided by abundant cross-ring and "elimination" fragment ions in the MALDI-CID spectra that gave extensive structural information. Furthermore, the fragmentation characteristics of N-glycans reductively aminated with 2-aminobenzoic acid and 2-aminobenzamide were compared. The identification of N-glycans containing 3-linked core fucose was facilitated by distinctive ions present only in the MALDI-CID spectra of 2-aminobenzoic acid-labeled oligosaccharides. To our knowledge, this is the first MS/MS-based technique that allows confident identification of N-glycans containing 3-linked core fucose, which is a major allergenic determinant on insect and plant glycoproteins.

  20. Long-Period Fiber Grating Sensors for the Measurement of Liquid Level and Fluid-Flow Velocity

    Directory of Open Access Journals (Sweden)

    Jian-Neng Wang

    2012-04-01

    Full Text Available This paper presents the development and assessment of two types of Long Period Fiber Grating (LPFG-based sensors including a mobile liquid level sensor and a reflective sensor for the measurement of liquid level and fluid-flow velocity. Shewhart control charts were used to assess the liquid level sensing capacity and reliability of the mobile CO2-laser engraved LPFG sensor. There were ten groups of different liquid level experiment and each group underwent ten repeated wavelength shift measurements. The results showed that all measurands were within the control limits; thus, this mobile sensor was reliable and exhibited at least 100-cm liquid level measurement capacity. In addition, a reflective sensor consisting of five LPFGs in series with a reflective end has been developed to evaluate the liquid level and fluid-flow velocity. These five LPFGs were fabricated by the electrical arc discharge method and the reflective end was coated with silver by Tollen’s test. After each liquid level experiment was performed five times, the average values of the resonance wavelength shifts for LPFG Nos. 1–5 were in the range of 1.35–9.14 nm. The experimental findings showed that the reflective sensor could be used to automatically monitor five fixed liquid levels. This reflective sensor also exhibited at least 100-cm liquid level measurement capacity. The mechanism of the fluid-flow velocity sensor was based on analyzing the relationship among the optical power, time, and the LPFG’s length. There were two types of fluid-flow velocity measurements: inflow and drainage processes. The differences between the LPFG-based fluid-flow velocities and the measured average fluid-flow velocities were found in the range of 8.7–12.6%. For the first time to our knowledge, we have demonstrated the feasibility of liquid level and fluid-flow velocity sensing with a reflective LPFG-based sensor without modifying LPFGs or coating chemical compounds.

  1. Conditions for settling liquid levels by means of gamma-ray relay control

    Energy Technology Data Exchange (ETDEWEB)

    Wakabayashi, N [Kobe Univ. (Japan). Faculty of Engineering

    1976-03-01

    Using a control action which consists of infusion and exhaust at constant speeds and a neutral zone to maintain liquid levels within a given range, a gamma-ray source, a detector, and two relays at the upper and lower limits of the counting rate were provided. The optimum condition in this case is discussed and confirmed experimentally. Since a counting rate-meter has a time constant and its output is subject to the statistical fluctuation, the liquid level may overrun the opposite limit, move again after settling within the range, or drift far out of the range by a load before actuation of the relay. Formulas are derived providing the conditions such that these phenomena will not occur more frequently than a tolerant probability. These give the relations between the counting rates at the upper and lower limits, the time constant of the rate-meter, the multipliers of the standard deviations of the counting rates, the infusing and exhausting speeds, and the hysteresis widths of the limiting relays. Since it can be said that the first two of the five quantities should be smaller and the next two greater, the optimum condition can be determined from the formulas. When the infusing and exhausting speeds are the same and the hysteresis widths are equal, the formulas show that the optimum is a case where the ratio of the counting rates at the two limits, which is taken smaller than unity, is small, and where each hysteresis width is equal to 0.34 times the difference between the two counting rates, almost regardless of the value of their ratio. The above-mentioned deductions were examined in a system constructed with a backscattered gamma-ray type level gauge and a controller for infusion and exhaust of water. Its results almost agreed with those of the deductions when the multipliers of the standard deviations are substituted for by 2.

  2. Magnesium sulfate reduces formalin-induced orofacial pain in rats with normal magnesium serum levels.

    Science.gov (United States)

    Srebro, Dragana P; Vučković, Sonja M; Dožić, Ivan S; Dožić, Branko S; Savić Vujović, Katarina R; Milovanović, Aleksandar P; Karadžić, Branislav V; Prostran, Milica Š

    2018-02-01

    In humans, orofacial pain has a high prevalence and is often difficult to treat. Magnesium is an essential element in biological a system which controls the activity of many ion channels, neurotransmitters and enzymes. Magnesium produces an antinociceptive effect in neuropathic pain, while in inflammatory pain results are not consistent. We examined the effects of magnesium sulfate using the rat orofacial formalin test, a model of trigeminal pain. Male Wistar rats were injected with 1.5% formalin into the perinasal area, and the total time spent in pain-related behavior (face rubbing) was quantified. We also spectrophotometrically determined the concentration of magnesium and creatine kinase activity in blood serum. Magnesium sulfate administered subcutaneously (0.005-45mg/kg) produced significant antinociception in the second phase of the orofacial formalin test in rats at physiological serum concentration of magnesium. The effect was not dose-dependent. The maximum antinociceptive effect of magnesium sulfate was about 50% and was achieved at doses of 15 and 45mg/kg. Magnesium did not affect increase the levels of serum creatine kinase activity. Preemptive systemic administration of magnesium sulfate as the only drug can be used to prevent inflammatory pain in the orofacial region. Its analgesic effect is not associated with magnesium deficiency. Copyright © 2017 Institute of Pharmacology, Polish Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  3. Estimation of low level gross alpha activities in the radioactive effluent using liquid scintillation counting technique

    International Nuclear Information System (INIS)

    Bhade, Sonali P.D.; Johnson, Bella E.; Singh, Sanjay; Babu, D.A.R.

    2012-01-01

    A technique has been developed for simultaneous measurement of gross alpha and gross beta activity concentration in low level liquid effluent samples in presence of higher activity concentrations of tritium. For this purpose, alpha beta discriminating Pulse Shape Analysis Liquid Scintillation Counting (LSC) technique was used. Main advantages of this technique are easy sample preparation, rapid measurement and higher sensitivity. The calibration methodology for Quantulus1220 LSC based on PSA technique using 241 Am and 90 Sr/ 90 Y as alpha and beta standards respectively was described in detail. LSC technique was validated by measuring alpha and beta activity concentrations in test samples with known amount of 241 Am and 90 Sr/ 90 Y activities spiked in distilled water. The results obtained by LSC technique were compared with conventional planchet counting methods such as ZnS(Ag) and end window GM detectors. The gross alpha and gross beta activity concentrations in spiked samples, obtained by LSC technique were found to be within ±5% of the reference values. (author)

  4. The emergency avoidance solidification campaign of liquid low-level waste at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Myrick, T.E.; Helms, R.E.; Scanlan, T.F.; Schultz, R.M.; Scott, C.B.; Williams, L.C.; Homan, F.J.; Keigan, M.V.; Monk, T.H.; Morrow, R.W.; Van Hoesen, S.D.; du Mont, S.P.

    1992-01-01

    Since the beginning of nuclear research and development activities at the Oak Ridge National Laboratory (ORNL) in 1943, the generation, collection, treatment, storage, and disposal of the liquid low-level waste (LLLW) stream has been an integral part of ORNL's waste management operations. This waste stream, consisting principally of a high nitrate (4.5 molar), high pH (pH 13--14) mixture of reactor, hot cell, and research laboratory liquid radioactive wastes (<5 Ci/gal), has been treated and disposed of in a variety of ways over the years. Most recently, the hydrofracture technology had been used for deep-well disposal of a grout mix of LLLW, cement, fly ash, and other additives. In 1984, this disposal technique was discontinued due to regulatory permitting issues and the need for extensive facility modifications for future operations. With loss of this disposal capability and the continued generation of LLLW by ORNL research activities, the limited tank storage capacity was rapidly being depleted

  5. Studies on gelation of sodium silicate hydrosol for immobilization of high level liquid waste (HLLW).

    Energy Technology Data Exchange (ETDEWEB)

    Abdel Raouf, M W [Hot Lab. Centre, Atomic Energy Authority, Cairo (Egypt); Sharaf El-deen, A N; El-Dessouky, M M [Military Technical College, Kobry El-Kobbah, Cairo (Egypt)

    1995-10-01

    Immobilization of the simulated high-level liquid waste (HLLW) was performed via the gelation with sodium silicate hydrosol at room temperature. The simulated waste in this study, was represented by the electrolytes of Li, Na, K, Cs, Co and Sr at different concentrations. Specific loading of the liquid waste with 0.6 M Mg (NO{sub 3})2 and tailoring with Al salts were tried during most of the gelation processes. Mineral acid (HCl or {sub 3}) were added during the gelation processes to achieve the gel point, especially when lower concentrations of the simulated waste were used. The obtained hydrogel were dried to obtain the solid gel form. The gelation processes were investigated in terms of the different factors that affected them, namely: temperature, pH, changes in the concentration of the initial hydrosol and the used electrolytes. The efficiency of the gelation processes was investigated from the ratio of the amount of simulated waste reacted (m mole) to the initial silicate used (m mole), i.e. X value. Lower X values were observed when using multi valent cations (higher polarizing power). A special effect of increasing the sorption of metal cations in the silica matrix was observed when Al{sup 3+} replaced Si{sup 4+} in the three-dimensional network structure of the matrix. 3 figs., 7 tabs.

  6. Application of PSD for low level alpha counting using liquid scintillation counting

    International Nuclear Information System (INIS)

    Krishnamachari, G.; Vaze, P.K.; Iyer, M.R.

    1989-01-01

    In the liquid scintillator the light produced by alpha particles decays differently than those produced by electrons. Pulse shape discrimination (PSD) methods are employed to estimate low levels of alpha emitting radionuclides by reducing the background due to either beta or gamma events. An attempt is being made to develop a liquid scintillation counting sytem using a simple PSD circuit to achieve a background of 0.01 counts/min. The PSD circuit is based on measuring zero cross over points to differentiate particle types. The input signal is first differentiated by a delay line and subsequently by a RC circuit. The width of the initial part of the doubly differentiated pulse is different for alpha and beta pulses. This width is converted to amplitude by a time-to-amplitude converter (TAC). The higher amplitude pulses from the TAC are due to alpha particles and they are separated by an integral discriminator. The output from the integral discriminator opens a linear gate to record the pulse height spectrum. The figure of merit of the PSD circuit and background in the alpha energy channel have been worked out using different scintillator types. (author). 4 figs

  7. Update of the management strategy for Oak Ridge National Laboratory Liquid Low-Level Waste

    International Nuclear Information System (INIS)

    Robinson, S.M.; Abraham, T.J.; DePaoli, S.M.; Walker, A.B.

    1995-04-01

    The strategy for management of the Oak Ridge National Laboratory's (ORNL) radioactively contaminated liquid waste was reviewed in 1991. The latest information available through the end of 1990 on waste characterization, regulations, US Department of Energy (DOE) budget guidance, and research and development programs was evaluated to determine how the strategy should be revised. Few changes are needed to update the strategy to reflect new waste characterization, research, and regulatory information. However, recent budget guidance from DOE indicates that minimum funding will not be sufficient to accomplish original objectives to upgrade the liquid low-level waste (LLLW) system to comply with the Federal Facilities Agreement, provide long-term LLLW treatment capability, and minimize environmental, safety, and health risks. Options are presented that might allow the ORNL LLLW system to continue operations temporarily, but they would significantly reduce its capabilities to handle emergency situations, provide treatment for new waste streams, and accommodate waste from the Environmental Restoration Program and from decontamination and decommissioning of surplus facilities. These options are also likely to increase worker radiation exposure, risk of environmental insult, and generation of solid waste for on-site and off-site disposal/storage beyond existing facility capacities. The strategy will be fully developed after receipt of additional guidance. The proposed budget limitations are too severe to allow ORNL to meet regulatory requirements or continue operations long term

  8. Status of the ORNL liquid low-level waste management upgrades

    International Nuclear Information System (INIS)

    Robinson, S.M.; Kent, T.E.; DePaoli, S.M.

    1995-08-01

    The strategy for management of the Oak Ridge National Laboratory's (ORNL's) radioactively contaminated liquid waste was reviewed. The latest information on waste characterization, regulations, US Department of Energy (DOE) budget guidance, and research and development programs was evaluated to determine how the strategy should be revised. Few changes are needed to update the strategy to reflect new waste characterization, research, and regulatory information. However, recent budget guidance from DOE indicates that minimum funding will not be sufficient to accomplish original objectives to upgrade the liquid low-level waste (LLLW) system to be in compliance with the Federal Facilities Agreement compliance, provide long-term LLLW treatment capability, and minimize Environmental Safety ampersand Health risks. Options are presented that might allow the ORNL LLLW system to continue operations temporarily but significantly reduce its capabilities to handle emergency situations, provide treatment for new waste streams, and accommodate waste from the Environmental Restoration Program and from decontamination and decommissioning of surplus facilities. These options are also likely to increase worker radiation exposure, risk of environmental insult, and generation of solid waste for on-site and off-site disposal/storage beyond existing facility capacities. The strategy will be fully developed after receiving additional guidance. The proposed budget limitations are too severe to allow ORNL to meet regulatory requirements or continue operations long term

  9. Evaporation of low-activity-level liquid waste at Tokai Reprocessing Plant, 1

    International Nuclear Information System (INIS)

    Nojima, Yasuo; Nemoto, Yuichi; Fukushima, Misao; Shibuya, Jun; Miyahara, Kenji

    1983-01-01

    The operation of Tokai reprocessing plant started in 1977. The determination of the decontamination factors (DF) of the evaporators for low activity level liquid waste (LALW) has been made through the operation. This paper deals with the examination of the first evaporator located at the LALW treatment plant. The operational principle and condition of the evaporator system are briefly explained. The effects of wire-mesh demisters and liquid properties on the decontamination factor were examined in this study. The results are summarized as follows: (1) The DF decreased with the increasing vapor mass velocity on account of entrainment. (2) The DF was able to be improved by using wire-mesh demisters when the vapor mass velocity was less than 2,500 kg/m 2 h. Practically, the most suitable vapor velocity for the evaporator was around 2,000 kg/m 2 h. (3) The DF in the evaporator for 137 Cs, 144 Ce, 90 Sr and 106 Ru was between 10 3 and 10 4 . Regarding 106 Ru, the DF in acid evaporation was less than that in alkaline evaporation. (Aoki, K.)

  10. Study of shrimp shell derivatives for treating of low-level radioactive liquid wastes

    Energy Technology Data Exchange (ETDEWEB)

    Hayeripour, S. [Tonkabon Islamic Azad Univ., Tonkabon (Iran, Islamic Republic of). College of the Environment; Malmasi, S. [North Tehran Islamic Azad Univ., Tehran (Iran, Islamic Republic of). College of the Environment

    2006-07-01

    Chitin derivatives can be used to treat liquid wastes that include heavy metals of radionuclides. In this study, 4 types of chitin derivatives from shrimp shell waste were investigated for their potential in decontaminating and treating low-level radioactive liquid waste (LLW). The adsorption of caesium (Cs); cobalt (Co); and manganese (Mn) isotopes on chitin derivatives were investigated using a batch and column system with variations in diameter, pH, and length of treatment. Chitin derivatives included shrimp shells; de-mineralized shrimp shells; chitin extracted from shrimp shells; and chitosan extracted from shrimp shell waste. Three types of simulated solutions were prepared to study and compare adsorption performance: (1) a mono cationic solution consisting of stable isotopes; (2) a solution containing 3 stable cations; and (3) a simulated radioactive waste containing Cs-137, Co-60, and Mn-54. Results of the experiments showed that all 4 chitin derivatives were capable of adsorbing the isotopes. Despite its low pH, chitosan showed the highest adsorption efficiency. It was concluded that shrimps shells provided unreliable results under different operating conditions. The demineralized shells were suitable for removing Co from solutions. Row shells were not recommended as a suitable adsorbent for radionuclides removal. 14 refs., 2 tabs., 6 figs.

  11. The levels of adipokines in relation to hormonal changes during the menstrual cycle in young, normal-weight women

    Directory of Open Access Journals (Sweden)

    Katarzyna Wyskida

    2017-11-01

    Full Text Available Context: The aim of this study was to assess the plasma leptin, adiponectin, resistin, visfatin/NAMPT, omentin-1, vaspin, apelin, TNF-α, IL-6 and RBP4 levels in relation to hormonal changes during the menstrual cycle in young, healthy, normal-weight women. Methods: The study involved 52 young, healthy, normal-weight women. Anthropometric parameters, body composition and levels of plasma leptin, adiponectin, resistin, visfatin/NAMPT, omentin-1, vaspin, apelin, TNF-α, IL-6 and RBP4 in addition to serum FSH, LH, estradiol, progesterone, 17-OH progesterone, androgens, SHBG and insulin concentrations were measured during a morning in fasting state three times: between days 2–4, days 12–14 and days 24–26 of the menstrual cycle. Results: Plasma adiponectin, omentin-1, resistin and visfatin/NAMPT, apelin, TNF-α, IL-6 and RBP4 concentrations were stable during the menstrual cycle, while leptin and vaspin levels were significantly higher in both the midcycle and the luteal phases than those in the follicular phase. Multivariate regression analyses revealed that changes in leptin and vaspin levels between the follicular and the luteal phase are strongly related to changes in total testosterone levels. Conclusions: Our results revealed stable levels of adipokines during the phases of the physiological menstrual cycle, except for leptin and vaspin, which showed increased levels in both the midcycle and the luteal phases. This effect was significantly associated with changes in the secretion of testosterone, 17-OH progesterone and insulin in the luteal phase.

  12. Exposure to meat-derived carcinogens and bulky DNA adduct levels in normal-appearing colon mucosa.

    Science.gov (United States)

    Ho, Vikki; Brunetti, Vanessa; Peacock, Sarah; Massey, Thomas E; Godschalk, Roger W L; van Schooten, Frederik J; Ashbury, Janet E; Vanner, Stephen J; King, Will D

    2017-09-01

    Meat consumption is a risk factor for colorectal cancer. This research investigated the relationship between meat-derived carcinogen exposure and bulky DNA adduct levels, a biomarker of DNA damage, in colon mucosa. Least squares regression was used to examine the relationship between meat-derived carcinogen exposure (PhIP and meat mutagenicity) and bulky DNA adduct levels in normal-appearing colon tissue measured using 32 P-postlabelling among 202 patients undergoing a screening colonoscopy. Gene-diet interactions between carcinogen exposure and genetic factors relevant to biotransformation and DNA repair were also examined. Genotyping was conducting using the MassARRAY ® iPLEX ® Gold SNP Genotyping assay. PhIP and higher meat mutagenicity exposures were not associated with levels of bulky DNA adducts in colon mucosa. The XPC polymorphism (rs2228001) was found to associate with bulky DNA adduct levels, whereby genotypes conferring lower DNA repair activity were associated with higher DNA adduct levels than the normal activity genotype. Among individuals with genotypes associated with lower DNA repair (XPD, rs13181 and rs1799179) or detoxification activity (GSTP1, rs1695), higher PhIP or meat mutagenicity exposures were associated with higher DNA adduct levels. Significant interactions between the XPC polymorphism (rs2228000) and both dietary PhIP and meat mutagenicity on DNA adduct levels was observed, but associations were inconsistent with the a priori hypothesized direction of effect. Exposure to meat-derived carcinogens may be associated with increased DNA damage occurring directly in the colon among genetically susceptible individuals. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Physical activity opposes the age-related increase in skeletal muscle and plasma endothelin-1 levels and normalizes plasma endothelin-1 levels in individuals with essential hypertension

    DEFF Research Database (Denmark)

    Nyberg, Michael Permin; Mortensen, Stefan Peter; Hellsten, Ylva

    2013-01-01

    performed lifelong physical activity had similar plasma and muscle endothelin-1 levels as the young controls and had higher ET(A) receptor levels. CONCLUSION: Our findings suggest that aerobic exercise training opposes the age-related increase in skeletal muscle and plasma endothelin-1 levels and normalizes......AIMS: Endothelin-1 has potent constrictor and proliferative activity in vascular smooth muscle, and essential hypertension and aging are associated with increased endothelin-1-mediated vasoconstrictor tone. The aim of this study was to investigate the effect of physical activity, hypertension...... and age on endothelin-1 levels in plasma and skeletal muscle and endothelin receptors in skeletal muscle in human subjects. METHODS: In study 1, normotensive (46 ± 1 years, n = 11) and hypertensive (47 ± 1 years, n = 10) subjects were studied before and after 8 weeks of aerobic exercise training. In study...

  14. Physical activity opposes the age-related increase in skeletal muscle and plasma endothelin-1 levels and normalizes plasma endothelin-1 levels in individuals with essential hypertension.

    Science.gov (United States)

    Nyberg, M; Mortensen, S P; Hellsten, Y

    2013-03-01

    Endothelin-1 has potent constrictor and proliferative activity in vascular smooth muscle, and essential hypertension and aging are associated with increased endothelin-1-mediated vasoconstrictor tone. The aim of this study was to investigate the effect of physical activity, hypertension and age on endothelin-1 levels in plasma and skeletal muscle and endothelin receptors in skeletal muscle in human subjects. In study 1, normotensive (46 ± 1 years, n = 11) and hypertensive (47 ± 1 years, n = 10) subjects were studied before and after 8 weeks of aerobic exercise training. In study 2, young (23 ± 1 years, n = 8), older lifelong sedentary (66 ± 2 years, n = 8) and older lifelong endurance-trained (62 ± 2 years, n = 8) subjects were studied in a cross-sectional design. Skeletal muscle and plasma endothelin-1 levels were increased with age and plasma endothelin-1 levels were higher in hypertensive than normotensive individuals. Eight weeks of exercise training normalized plasma endothelin-1 levels in the hypertensive subjects and increased the protein expression of the ET(A) receptor in skeletal muscle of normotensive subjects. Similarly, individuals that had performed lifelong physical activity had similar plasma and muscle endothelin-1 levels as the young controls and had higher ET(A) receptor levels. Our findings suggest that aerobic exercise training opposes the age-related increase in skeletal muscle and plasma endothelin-1 levels and normalizes plasma endothelin-1 levels in individuals with essential hypertension. This effect may explain some of the beneficial effects of training on the cardiovascular system in older and hypertensive subjects. © 2012 The Authors Acta Physiologica © 2012 Scandinavian Physiological Society.

  15. The disposal of intermediate-level radioactive liquid waste by hydraulic fracturing process

    Energy Technology Data Exchange (ETDEWEB)

    Ruilin, Chen; Hanchen, Zhou; Yuzhu, Gao; Wen, Qiao; Wentao, Wang [Beijing Inst. of Nuclear Engineering (China)

    1994-12-31

    The hydraulic fracturing process is characterized by combination of the treatment with the disposal of ILLW (intermediate-level liquid waste). It is of cement solidification in deep geology stratum. First of all, it is necessary to select a suitable disposal site with detailed information on geology and hydrogeology. The process has such advantages as simple, low cost, large capacity of disposal, safe and reliable in technology. It is an attractive process of ILLW. Since 1980`s, the research and the concept design of the hydraulic fracturing process have been initiated for disposal of ILLW. It is demonstrated by the field tests. The authors considered that the geological structure near Sichuan Nuclear Fuel Plant fits the disposal of ILLW by the hydraulic fracturing process.

  16. Separation and recovery of sodium nitrate from low-level radioactive liquid waste by electrodialysis

    International Nuclear Information System (INIS)

    Meguro, Yoshihiro; Kato, Atsushi; Watanabe, Yoko; Takahashi, Kuniaki

    2011-01-01

    An advanced method, in which electrodialysis separation of sodium nitrate and decomposition of nitrate ion are combined, has been developed to remove nitrate ion from low-level radioactive liquid wastes including nitrate salts of high concentration. In the electrodialysis separation, the sodium nitrate was recovered as nitric acid and sodium hydroxide. When they are reused, it is necessary to reduce the quantity of impurities getting mixed with them from the waste fluid as much as possible. In this study, therefore, a cation exchange membrane with permselectivity for sodium ion and an anion exchange membrane with permselectivity for monovalent anion were employed. Using these membranes sodium and nitrate ions were effectively removed form a sodium nitrate solution of high concentration. And also it was confirmed that sodium ion was successfully separated from cesium and strontium ions and that nitrate ion was separated from sulfate and phosphate ions. (author)

  17. Preliminary analysis of the ORNL Liquid Low-Level Waste system

    International Nuclear Information System (INIS)

    Abraham, T.J.; DePaoli, S.M.; Robinson, S.M.; Walker, A.B.

    1994-08-01

    The objective of this report is to summarize the status of the Liquid Low-Level Waste (LLLW) Systems Analysis project. The focus of this project has been to collect and tabulate data concerning the LLLW system, analyze the current LLLW system operation, and develop the information necessary for the development of long-term treatment options for the LLLW generated at ORNL. The data used in this report were collected through a survey of Oak Ridge National Laboratory (ORNL) literature, various letter reports, and a survey of all current LLLW generators. These data are also being compiled in a user friendly database for ORNL-wide distribution. The database will allow the quick retrieval of all information collected on the ORNL LLLW system and will greatly benefit any LLLW analysis effort. This report summarizes the results for the analyses performed to date on the LLLW system

  18. The disposal of intermediate-level radioactive liquid waste by hydraulic fracturing process

    International Nuclear Information System (INIS)

    Chen Ruilin; Zhou Hanchen; Gao Yuzhu; Qiao Wen; Wang Wentao

    1993-01-01

    The hydraulic fracturing process is characterized by combination of the treatment with the disposal of ILLW (intermediate-level liquid waste). It is of cement solidification in deep geology stratum. First of all, it is necessary to select a suitable disposal site with detailed information on geology and hydrogeology. The process has such advantages as simple, low cost, large capacity of disposal, safe and reliable in technology. It is an attractive process of ILLW. Since 1980's, the research and the concept design of the hydraulic fracturing process have been initiated for disposal of ILLW. It is demonstrated by the field tests. The authors considered that the geological structure near Sichuan Nuclear Fuel Plant fits the disposal of ILLW by the hydraulic fracturing process

  19. Seismic analysis of the ICPP high level liquid waste tanks and vaults

    International Nuclear Information System (INIS)

    Uldrich, E.D.; Malik, L.E.

    1991-01-01

    Two buried, closely spaced, reinforced concrete vaults founded on base rock were evaluated for gravity and safe shutdown earthquake loads. These vaults enclose steel tanks used to store high level radioactive liquid waste. Detailed 3-dimensional finite element models were used for state-of-the-art structure-soil-structure interaction (SSSI) analyses. Three soil dynamic property profiles were used to address soil variability. Vault accelerations are not significantly affected by the variability of soil dynamic properties. Lower bound soil properties yield maximum member forces and moments. Demands on the side closer to the other vault due to horizontal motions are lower due to SSSI effects. Combined gravity and seismic demand on the vault force resisting system was calculated. The vaults were qualified, using member capacities based on current design codes

  20. Fundamental study on the extraction of transuranium elements from high-level liquid waste

    International Nuclear Information System (INIS)

    Kubota, Masumitsu; Morita, Yasuji; Tochiyama, Osamu; Inoue, Yasushi.

    1988-01-01

    A great many extractants have been studied for the separation of transuranium elements. The present study deals with the survey and classification of the extractants appearing in literature, bearing in mind the relationship between the molecular structure of extractants and their extractability for the transuranium elements from the standpoint of their selective separation from high-level liquid waste (HLW) generated from fuel reprocessing. The extractants surveyed were classified into six groups; unidentate neutral organophosphorus compounds, bidentate neutral organophosphorus compounds, acidic organophosphorus compounds, amines and ammonium salts, N,N-disubstituted amides and the other compounds. These extractants are not always applicable to the separation of transuranium elements from HLW because of their limitations in extractability and radiation durability. Only a limited number of extractants belonging to the bidentate neutral organophosphorus compounds and the acidic organophosphorus compounds are considered to be suitable for the present purpose. (author)

  1. Application of chitin and zeolite adsorbents for treatment of low level radioactive liquid wastes

    International Nuclear Information System (INIS)

    Moattar, F.; Hayeripour, S.

    2004-01-01

    Two types of shrimp chitin derivatives and two types of Iranian natural zeolite derivates were studied for adsorption and treatment of low-level radioactive liquid waste. Chitin with lowers than 10% and chitosan with higher than 90% deacetylation factor were selected as neutral organic adsorbents. Natural clinoptilolite of Firuzkooh area and Na from derivates of it were selected as natural inorganic adsorbents. The static and dynamic ion exchange experimental results show that the ad adsorption efficiency depend on particle size, Ph, adsorbent type, deacetylation factor ( in chitin adsorbents) and cation type. The best Cs adsorption occurred in Na from clinoptilolite. Nevertheless chitin derivatives, particularly chitosan, are more efficient than zeolite adsorbents for removing of radionuclides such as 137 Cs, 54 Mn, 90 Sr and 60 Co. Adsorption performance was discussed and compared with each other

  2. Ultra Low Level Tritium Analysis Method Using a Liquid Scintillation Counter

    Energy Technology Data Exchange (ETDEWEB)

    Noh, S. J.; Kim, H. J.; Kim, H.; Lim, H. J.; Lee, M. W.; Jeong, D. H.; Kim, J. K.; Kang, Y. R. [Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of); Nam, S. H. [Inje University, Gimhae, (Korea, Republic of)

    2015-05-15

    To evaluate {sup 3}H concentration in the atmosphere more accurately compared to the conventional methods, the author of this paper intended to suggest more improved analytical methods and derived the elements which might occur during analysis or required improvements. The method suggested in this study is able to reduce the uncertainty and errors which may be existent in evaluating the {sup 3}H concentration of environmental sample s and thus will serve as the best solution in the technical and economic point of view. Liquid Scintillation Counter is the most widely used to analyze ultra-low level {sup 3}H by using CPM / DPM Counting Mode using external radiation source and Spectrum Plot Mode using internal radiation source. In CPM / DPM Counting Mode, multiple samples can be measured by single calibration despite its rather higher background whereas Spectrum Plot Mode requires more time and cost to analyze multiple samples despite its reliability to reduce the contribution of other radionuclides.

  3. Circulating thrombopoietin levels in normal healthy blood donors and in aplastic anemia patients in relation to disease severity

    Directory of Open Access Journals (Sweden)

    Abhay Singh

    2015-01-01

    Full Text Available Background: Thrombopoietin (TPO is the key hematopoietic growth factor regulating the production of platelets from bone marrow megakaryocytes and maintaining platelet hemostasis. This study was done to find any relationship between the levels of thrombopoietin and the severity of disease in patients with aplastic anemia. Materials and Methods: Serum samples were collected from 52 patients with a confirmed diagnosis of aplastic anemia and 45 normal healthy blood donors of both sexes over a period of 2 years, and TPO was estimated by using commercially available TPO-specific-enzyme-linked immunosorbent assay. Results: The median TPO level of 1190 pg/ml (range 625-7651 pg/ml in aplastic anemia patients was significantly higher than the median TPO level of 121.1 pg/ml (81.25-237.7 pg/ml in normal healthy blood donors (P = 0.000. No significant difference was observed in TPO levels of male and female patients (P = 0.453. The median TPO concentrations observed in very severe aplastic anemia, severe aplastic anemia, and nonsevere aplastic anemia were 2765 pg/ml (range 625-6451 pg/ml, 1190 pg/ml (range 672.1-7651 pg/ml, and 1111.5 pg/ml (range 761.1-2289.2 pg/ml, respectively. TPO in patients of very severe aplastic anemia was significantly higher than patients of nonsevere aplastic anemia (P = 0.043, with no significant relation among rest of the groups. Discussion: TPO levels in aplastic anemia patients were significantly higher than in healthy blood donors; however, in aplastic anemia patients TPO levels were significantly higher only in patients with very severe disease.

  4. An optimized approach towards the treatment of high level liquid waste in the nuclear cycle

    International Nuclear Information System (INIS)

    Maio, V.; Todd, T.; Law, J.; Roach, J.; Sabharwall, P.

    2006-01-01

    Full text: One key long-standing issue that must be overcome to realize the successful growth of nuclear power is an economical, politically acceptable, stakeholder-compatible, and technically feasible resolution pertaining to the safe treatment and disposal of high-level liquid radioactive waste (HLLW). In addition to spent nuclear reactor fuel, HLLW poses a unique challenge in regard to environmental and security concerns, since future scenarios for a next generation of domestic and commercialized nuclear fuel cycle infrastructures must include reprocessing - the primary source of HLLW-to ensure the cost effectiveness of nuclear power as well as mitigate any threats as related to proliferation. Past attempts to immobilize HLLW - generated by both the weapons complex and the commercial power sector-have been plagued by an inability to convince the public and some technical peer reviewers that any proposed geological disposal sites (e.g., Yucca Mountain) can accommodate and contain the HLLW for a period of geological time equivalent to ten fold the radiological half-life of the longest lived of the actinides remaining after reprocessing. The paper explores combined equipment and chemical processing approaches for advancing and economizing the immobilization of high level liquid waste to ensure its long term durability, its decoupling from the unknown behavior of the repository over long geological time periods, and its economical formulation as required for the nuclear fuel cycle of the future. One approach involves the investigation of crystalline based waste forms as opposed to the glass/amorphous based waste forms, and how recent developments in crystalline forms show promise in sequestering the long lived actinides for over tens of millions of years. Another approach -compatible with the first- involves the use of an alternative melter technology-the Cold Crucible Induction Melter (CCIM)- to overcome the engineering material problems of Joule Heated Meters (JHM

  5. Liquid Metallic Hydrogen II. A Critical Assessment of Current and Primordial Helium Levels in the Sun

    Directory of Open Access Journals (Sweden)

    Robitaille P.-M.

    2013-04-01

    lar winds which, though highly variable, provide a wealth of data. Evaluations of pr imordial helium levels based on 1 the spectroscopic study of H-II regions and 2 microwav e anisotropy data, re- main highly questionable. Current helium levels, both with in the stars (Robitaille J. C. and Robitaille P.-M. Liquid Metallic Hydrogen III. Interca lation and Lattice Exclusion versus Gravitational Settling, and Their Consequences Rel ative to Internal Structure, Surface Activity, and Solar Winds in the Sun. Progr. Phys. , 2013, v. 2, in press and the universe at large, appear to be overstated. A careful con sideration of available ob- servational data suggests that helium abundances are consi derably lower than currently believed.

  6. Serum estradiol levels associated with specific gene expression patterns in normal breast tissue and in breast carcinomas

    International Nuclear Information System (INIS)

    Haakensen, Vilde D; Børresen-Dale, Anne-Lise; Helland, Åslaug; Bjøro, Trine; Lüders, Torben; Riis, Margit; Bukholm, Ida K; Kristensen, Vessela N; Troester, Melissa A; Homen, Marit M; Ursin, Giske

    2011-01-01

    High serum levels of estradiol are associated with increased risk of postmenopausal breast cancer. Little is known about the gene expression in normal breast tissue in relation to levels of circulating serum estradiol. We compared whole genome expression data of breast tissue samples with serum hormone levels using data from 79 healthy women and 64 breast cancer patients. Significance analysis of microarrays (SAM) was used to identify differentially expressed genes and multivariate linear regression was used to identify independent associations. Six genes (SCGB3A1, RSPO1, TLN2, SLITRK4, DCLK1, PTGS1) were found differentially expressed according to serum estradiol levels (FDR = 0). Three of these independently predicted estradiol levels in a multivariate model, as SCGB3A1 (HIN1) and TLN2 were up-regulated and PTGS1 (COX1) was down-regulated in breast samples from women with high serum estradiol. Serum estradiol, but none of the differentially expressed genes were significantly associated with mammographic density, another strong breast cancer risk factor. In breast carcinomas, expression of GREB1 and AREG was associated with serum estradiol in all cancers and in the subgroup of estrogen receptor positive cases. We have identified genes associated with serum estradiol levels in normal breast tissue and in breast carcinomas. SCGB3A1 is a suggested tumor suppressor gene that inhibits cell growth and invasion and is methylated and down-regulated in many epithelial cancers. Our findings indicate this gene as an important inhibitor of breast cell proliferation in healthy women with high estradiol levels. In the breast, this gene is expressed in luminal cells only and is methylated in non-BRCA-related breast cancers. The possibility of a carcinogenic contribution of silencing of this gene for luminal, but not basal-like cancers should be further explored. PTGS1 induces prostaglandin E2 (PGE2) production which in turn stimulates aromatase expression and hence increases the

  7. Classification of Normal and Apoptotic Cells from Fluorescence Microscopy Images Using Generalized Polynomial Chaos and Level Set Function.

    Science.gov (United States)

    Du, Yuncheng; Budman, Hector M; Duever, Thomas A

    2016-06-01

    Accurate automated quantitative analysis of living cells based on fluorescence microscopy images can be very useful for fast evaluation of experimental outcomes and cell culture protocols. In this work, an algorithm is developed for fast differentiation of normal and apoptotic viable Chinese hamster ovary (CHO) cells. For effective segmentation of cell images, a stochastic segmentation algorithm is developed by combining a generalized polynomial chaos expansion with a level set function-based segmentation algorithm. This approach provides a probabilistic description of the segmented cellular regions along the boundary, from which it is possible to calculate morphological changes related to apoptosis, i.e., the curvature and length of a cell's boundary. These features are then used as inputs to a support vector machine (SVM) classifier that is trained to distinguish between normal and apoptotic viable states of CHO cell images. The use of morphological features obtained from the stochastic level set segmentation of cell images in combination with the trained SVM classifier is more efficient in terms of differentiation accuracy as compared with the original deterministic level set method.

  8. The Effect of Aspalathin on Levels of Sugar and Lipids in Streptozotocin-Induced Diabetic and Normal Rats

    Directory of Open Access Journals (Sweden)

    Mahmood Najafian

    2016-10-01

    Full Text Available Background Flavonoids have been reported as mammalian alpha-amylase inhibitors, a property which could be useful in the management of postprandial hyperglycemia in diabetes and its related disorders. Objectives In the present study the inhibitory effect of aspalathin as a flavonoid on alpha amylase activity and levels of sugar and lipids in rats, has been investigated. Methods In this experimental study, type inhibition of aspalatin on amylase and in the part of in vivo, the effect of aspalathin orally doses 5, 10, 20 and 40 mg/kg body weight on sugar and lipids levels was tested in a streptozotocin-induced model of diabetes and normal rats. The data were analyzed by one-sample Kolmogrov-Smirnov, Levene and ANOVA tests through SPSS version 22. Results The results showed that aspalathin is a competitive inhibitor for alpha amylase with Ki = 37.0 μM. In both diabetic and normal groups in all doses nearly dose dependent manner reduced blood glucose levels and beneficial effect on dyslipidemia were observed in diabetic rats, as well as reduction of disturbing consequences of diabetes such as high urine volume and water intake. Aspalathin was observed to have a weight loss-inductive effect, alongside with a reduction in food intake. Conclusions It seems that, this compound could be proposed as an antihyperglycemic and antihyperlipidemic agent in diabetes and potential therapeutic in obesity.

  9. Normal values of glomerular filtration rate in geriatrics in Bandung and its correlation with serum cystatin-C levels

    International Nuclear Information System (INIS)

    Resnaldi, A.; Yuliani, A.; Hidayat, B.; Kartamihardja, A.H.S.

    2007-01-01

    Full text: Determination of the normal values of glomerular filtration rate (GFR) is an essential part of the evaluation of patient with kidney disease. GFR almost linearly decreases with age at a mean annual rate of 0.8 ml/min/1.73 m2 over the age of 30 years old. According to NHANES III mean GFR for population with age > 60 years was 80 mL/min/1.73 m2. It is recommended for each centre to determine their own normal values of GFR for different age groups particularly in geriatric population. Recently, serum cystatin-C has been proposed as a new endogenous marker of glomerular filtration rate. Aim of the study was to determination of normal values of glomerular filtration rate (GFR) in geriatrics in Bandung and its correlation with serum Cystatin-C levels. Subjects were 24 males and 36 females (mean age 66.71 ± 6.7 years; range 60-87 yrs), without any renal and/or systemic disease. Creatinine clearance was estimated by using Cockroft-Gault formula and serum cystatin-C level were determined by using particle enhanced immunonephelometric method, while GFR values were determined by external body counting methods using Tc-99m DTPA ( Gates' methods ). Pearson correlation was used to determine correlation between variables and a P value < 0.05 is considered significant. Results and Discussion. Mean total GFR was 67.57 ml/min/1.73 m2 (SD ± 16.02), range from 45 to 100 ml/min/1.73 m2. Mean total GFR for male was 69.46 ml/min/1.73 m2, and female was 66.31 ml/min/1.73 m2, the difference was statistically significant (p < 0.05). The results were lower than NHANES III values. There was a better correlation between total GFR and cystatin-C level (r = -0.522 and p < 0.001) compared to total GFR and creatinine clearance (r 0.306 and p < 0.005). Mean creatinine clearance was 57.93 ml/min and serum cystatin-C was 0.97 mg/dl, the correlation was statistically significant (r -0.414 and p < 0.005). Conclusions: The normal values of GFR in geriatric population in Bandung were 69

  10. Investigation of prostaglandin levels in human milk after high performance liquid chromatography purification

    International Nuclear Information System (INIS)

    Wu-Wang, C.Y.; Neu, J.

    1986-01-01

    This study was conducted to investigate five prostaglandins (PGs), i.e. PGE 2 , PGF/sub 2α/, 13-14-dihydro-15-keto-PGF/sub 2α/ (DHKF/sub 2α/), thromboxane B 2 (TXB 2 ) and 6-keto-PGF/sub 1α/), measured by (RIA) after C 18 Sep-Pak extraction and reverse phase high performance liquid chromatography (HPLC). Two trials were performed. In each trial, 3-5 mature human milk samples were pooled, acidified and extracted for PGs. The separation of PGs by HPLC was achieved by using an isocratic solvent system of acetonitrile/water (pH 3.0) (32/68, V/V). The PG levels from the two trials were determined and averaged after monitoring the recoveries. The results indicate that PGE 2 and DHKF/sub 2α/ are the two major PGs found in extracted human milk. However, after HPLC purification, no predominant PG is found and the levels of all the five PGs are much lower compared to the extracted sample. Since the immunoreactive material was also detected in HPLC fractions not within the PG peak, low levels of PG found in human milk after HPLC is likely due to the purification step removing the bulk of nonspecific immunoreactive substances present in the sample

  11. Laboratory actinide partitioning: Whitlockite/liquid and influence of actinide concentration levels

    International Nuclear Information System (INIS)

    Benjamin, T.M.; Jones, J.H.; Heuser, W.R.; Burnett, D.S.

    1983-01-01

    Fission and alpha track radiography techniques have been used to measure partition coefficients (D) at trace (ppm) concentration levels for the actinide elements Th, U, and Pu between synthetic whitlockite and coexisting 'haplobasaltic' silicate liquid at 1 bar pressure and 1250 deg C at oxygen fugacities from 10 sup(-8.5) and 10sup(-0.7) bars. Pu is much more readily incorporated into crystalline phases than is U or Th under reducing conditions, because Pu is primarily trivalent, whereas U and Th are tetravalent. Definitive valence state assignments cannot be made, but our best estimates of corrected partition coefficients for Pu +3 , Pu +4 , Th +4 , U +4 , and U +6 are given for whitlockites. The effect of changing pressure and liquidus temperature is relatively small, which probably reflects a weak temperature dependence for D (whitlockite) but possibly could be due to cancellation of opposing temperature and pressure effects. Comparison of experiments at trace U levels with those containing percent concentrations of UO 2 indicate that Si is involved in the substitution of U in whitlockite with U + 2Si Ca + 2P being the most likely mechanism. Dsub(U) is lower, 0.3 vs 0.5, at percent levels compared to 20 ppm. This is best explained by the effect of U on melt structure or by a decrease in the fraction of tetravalent U at high concentrations. (author)

  12. A decreased soluble Klotho level with normal eGFR, FGF23, serum phosphate, and FEP in an ADPKD patient with enlarged kidneys due to multiple cysts.

    Science.gov (United States)

    Kanai, Takahiro; Shiizaki, Kazuhiro; Betsui, Hiroyuki; Aoyagi, Jun; Yamagata, Takanori

    2018-05-16

    Autosomal dominant polycystic kidney disease (ADPKD) is the most common hereditary renal disorder. ADPKD is characterized clinically by the presence of multiple bilateral renal cysts that lead to chronic renal failure. The cysts evolve from renal tubular epithelial cells that express the Klotho gene. Notably, Klotho acts as a co-receptor for fibroblast growth factor 23 (FGF23); in this context, it induces phosphaturia and maintains serum phosphate at a normal level. Many reports have shown that decreases in the soluble Klotho level and increases in the FGF23 level are associated with glomerular filtration rate (GFR) decline, but a recent study observed these changes in patient with normal eGFR. It remains unclear whether the decrease in the Klotho level precedes the increase in FGF23. Here, we present an ADPKD patient with enlarged kidneys due to multiple cysts who had a decreased soluble Klotho level but a normal eGFR and a normal FGF23 level. The patient's serum phosphate level was normal, as was the fractional excretion of phosphate (FEP). This appears to be the first reported case to show a decreased soluble Klotho level plus normal eGFR, FGF23, and FEP. These results suggest that Klotho decreases before FGF23 increases and further suggest that Klotho is not required to maintain normal serum phosphate levels in ADPKD if the FEP and serum phosphate levels are normal.

  13. Comparison of atomic-level and coarse-grained models for liquid hydrocarbons from molecular dynamics configurational entropy estimates

    NARCIS (Netherlands)

    Baron, R; de Vries, AH; Hunenberger, PH; van Gunsteren, WF

    2006-01-01

    Molecular liquids can be modeled at different levels of spatial resolution. In atomic-level (AL) models, all (heavy) atoms can be explicitly simulated. In coarse-grained (CG) models, particles (beads) that represent groups of covalently bound atoms are used as elementary units. Ideally, a CG model

  14. Subsurface disposal of liquid low-level radioactive wastes at Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Stow, S.H.; Haase, C.S.

    1986-01-01

    At Oak Ridge National Laboratory (ORNL) subsurface injection has been used to dispose of low-level liquid nuclear waste for the last two decades. The process consists of mixing liquid waste with cement and other additives to form a slurry that is injected under pressure through a cased well into a low-permeability shale at a depth of 300 m (1000 ft). The slurry spreads from the injection well along bedding plane fractures and forms solid grout sheets of up to 200 m (660 ft) in radius. Using this process, ORNL has disposed of over 1.5 x 10 6 Ci of activity; the principal nuclides are 90 Sr and 137 Cs. In 1982, a new injection facility was put into operation. Each injection, which lasts some two days, results in the emplacement of approximately 750,000 l (180,000 gal) of slurry. Disposal cost per liter is approximately $0.30, including capital costs of the facility. This subsurface disposal process is fundamentally different from other operations. Wastes are injected into a low-permeability aquitard, and the process is designed to isolate nuclides, preventing dispersion in groundwaters. The porosity into which wastes are injected is created by hydraulically fracturing the host formation along bedding planes. The site is in the structurally complex Valley and Ridge Province. The stratigraphy consists of lower Paleozoic rocks. Investigations are under way to determine the long-term hydrologic isolation of the injection zone and the geochemical impact of saline groundwater on nuclide mobility. Injections are monitored by gamma-ray logging of cased observation wells to determine grout sheet orientation after an injection. Recent monitoring work has involved the use of tiltmeters, surface uplift surveys, and seismic arrays. 26 refs., 7 figs

  15. Subsurface disposal of liquid low-level radioactive wastes at Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Stow, S.H.; Haase, C.S.

    1986-01-01

    At Oak Ridge National Laboratory (ORNL) subsurface injection has been used to dispose of low-level liquid nuclear waste for the last two decades. The process consists of mixing liquid waste with cement and other additives to form a slurry that is injected under pressure through a cased well into a low-permeability shale at a depth of 300 m. The slurry spreads from the injection well along bedding plane fractures and forms solid grout sheets of up to 200 m in radius. Using this process, ORNL has disposed of over 1.5 x 10 6 Ci of activity; the principal nuclides are 90 Sr and 137 Cs. In 1982, a new injection facility was put into operation. Each injection, which lasts some two days, results in the emplacement of approximately 750,000 liters of slurry. Disposal cost per liter is about $0.30, including capital costs of the facility. This subsurface disposal process is fundamentally different from other operations. Wastes are injected into a low-permeability aquitard, and the process is designed to isolate nuclides, preventing dispersion in groundwaters. The porosity into which wastes are injected is created by hydraulically fracturing the host formation along bedding planes. Investigations are under way to determine the long-term hydrologic isolation of the injection zone and the geochemical impact of saline groundwater on nuclide mobility. Injections are monitored by gamma-ray logging of cased observation wells to determine grout sheet orientation after an injection. Recent monitoring work has involved the use of tiltmeters, surface uplift surveys, and seismic arrays. Recent regulatory constraints may cause permanent cessation of the operation. Federal and state statutes, written for other types of injection facilities, impact the ORNL facility. This disposal process, which may have great applicability for disposal of many wastes, including hazardous wastes, may not be developed for future use

  16. The Treatment of Low Level Radioactive Liquid Waste Containing Detergent by Biological Activated Sludge Process

    International Nuclear Information System (INIS)

    Zainus Salimin

    2002-01-01

    The treatment of low level radioactive liquid waste containing persil detergent from laundry operation of contaminated clothes by activated sludge process has been done, for alternative process replacing the existing treatment by evaporation. The detergent concentration in water solution from laundry operation is 14.96 g/l. After rinsing operation of clothes and mixing of laundry water solution with another liquid waste, the waste water solution contains about ≤ 1.496 g/l of detergent and 10 -3 Ci/m 3 of Cs-137 activity. The simulation waste having equivalent activity of Cs-137 10 -3 Ci/m 3 , detergent content (X) 1.496, 0.748, 0.374, 0.187, 0.1496 and 0.094 g/l on BOD value respectively 186, 115, 71, 48, 19, and 16 ppm was processed by activated sludge in reactor of 18.6 l capacity on ambient temperature. It is used Super Growth Bacteria (SGB) 102 and SGB 104, nitrogen and phosphor nutrition, and aeration. The result show that bacteria of SGB 102 and SGB 104 were able to degrade the persil detergent for attaining standard quality of water release category B in which BOD values 6 ppm. It was need 30 hours for X ≤ 0.187 g/l, 50 hours for 0.187 < X ≤ 0.374 g/l, 75 hours for 0.374 < X ≤ 0.748, and 100 hours for 0.748 < X ≤ 1.496 g/l. On the initial period the bacteria of SGB 104 interact most quickly to degrade the detergent comparing SGB 102. Biochemical oxidation process decontaminate the solution on the decontamination factor of 350, Cs-137 be concentrate in sludge by complexing with the bacteria wall until the activity of solution be become very low. (author)

  17. What Are Normal Metal Ion Levels After Total Hip Arthroplasty? A Serologic Analysis of Four Bearing Surfaces.

    Science.gov (United States)

    Barlow, Brian T; Ortiz, Philippe A; Boles, John W; Lee, Yuo-Yu; Padgett, Douglas E; Westrich, Geoffrey H

    2017-05-01

    The recent experiences with adverse local tissue reactions have highlighted the need to establish what are normal serum levels of cobalt (Co), chromium (Cr), and titanium (Ti) after hip arthroplasty. Serum Co, Cr, and Ti levels were measured in 80 nonconsecutive patients with well-functioning unilateral total hip arthroplasty and compared among 4 bearing surfaces: ceramic-on-ceramic (CoC); ceramic-on-polyethylene (CoP); metal-on-polyethylene (MoP), and dual mobility (DM). The preoperative and most recent University of California, Los Angeles (UCLA) and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores were compared among the different bearing surfaces. No significant difference was found among serum Co and Cr levels between the 4 bearing surface groups (P = .0609 and P = .1577). Secondary analysis comparing metal and ceramic femoral heads demonstrated that the metal group (MoP, modular dual mobility (Stryker Orthopedics, Mahwah, NJ) [metal]) had significant higher serum Co levels compared with the ceramic group (CoC, CoP, MDM [ceramic]) (1.05 mg/L ± 1.25 vs 0.59 mg/L ± 0.24; P = .0411). Spearman coefficient identified no correlation between metal ion levels and patient-reported outcome scores. No serum metal ion level differences were found among well-functioning total hip arthroplasty with modern bearing couples. Significantly higher serum Co levels were seen when comparing metal vs ceramic femoral heads in this study and warrants further investigation. Metal ion levels did not correlate with patient-reported outcome measures. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Determination of Na+ and K+ ions in the high-level liquid waste by ion chromatography (IC)

    International Nuclear Information System (INIS)

    Chen Lianzhong; Ma Guilan

    1992-01-01

    The determination of Na + and k + ions in the high-level liquid waste is investigated using ion chromatography. In order to protect the low capacity ion exchange resin in single column IC and remove the transition metal as well as other heavy metal ions that are contained in liquid waste, the pretreatment column with EDTA chelating resin is used. Those impurity metal ions are strongly absorbed by EDTA chelating resin and 100% of Na + and K + ions in the solution are eluted. The ability of the decontamination of EDTA chelating resin is satisfactory. The sample of the high-level liquid waste is diluted appropriately, then an aliquot of the sample is passed through the pretreatment column with EDTA chelating resin, the eluate is analysed by single column ion chromatography. The precision of this method is better than 5% for the determination of Na + and K + ions (at μg· ml -1 level)

  19. Some problems in utilization system of FP nuclides and actinides in the high level liquid wastes

    International Nuclear Information System (INIS)

    Ichiyanagi, Katsuaki; Emura, Satoru

    1974-01-01

    There are three nuclides of sup(134/137)Cs for irradiation sources, 90 Sr for radioisotope thermoelectric generators, and 238 Pu for cardiac pacemakers, as the nuclides for which considerable demand is expected in near future among those contained in reprocessed high level liquid wastes. Technical problems are first described from the viewpoint of utilization system. Then the control system of reprocessed high level wastes is expained. Finally, economic possibility and problems in their utilization are discussed. Being in competition with 60 Co, the price of sup(134/137)Cs will be lower than that of 60 Co after a decade. The annual demand in 1985 may be 6.1 x 10 6 Ci. The conclusive factor of 90 Sr market price is hard to get because it finds no strong competitive nuclides. It may be about 20 yen/Ci after ten years. Demand is expected to be approximately 1.2 x 10 7 Ci/year. However it is pretty hard to pay the cost of group separation and solidification, storage and conversion to products with such gain. It is estimated that the balance of income and outgo would be almost profitable, if the utilization of FP nuclides would progress and the demand three times as large as this assumption would be developed. (Wakatsuki, Y.)

  20. Pore solution chemistry of simulated low-level liquid waste incorporated in cement grouts

    International Nuclear Information System (INIS)

    Kruger, A.A.

    1995-12-01

    Expressed pore solutions from simulated low level liquid waste cement grouts cured at room temperature, 50 degree C and 90 degree C for various duration were analyzed by standard chemical methods and ion chromatography. The solid portions of the grouts were formulated with portland cement, fly ash, slag, and attapulgite clay in the ratios of 3:3:3:1. Two different solutions simulating off-gas condensates expected from vitrification of Hanford low level tank wastes were made. One is highly alkaline and contains the species Na + , P0 4 3- , N0 2 - , NO 3 - and OH - . The other is carbonated and contains the species, Na + , PO 4 3- , NO 2 - , NO 3 - , and CO 3 2- . In both cases phosphate rapidly disappeared from the pore solution, leaving behind sodium in the form of hydroxide. The carbonates were also removed from the pore solution to form calcium carbonate and possibly calcium monocarboaluminate. These reactions resulted in the increase of hydroxide ion concentration in the early period. Subsequently there was a significant reduction OH - and Na + ion concentrations. In contrast high concentration of N0 2 - and N0 3 - were retained in the pore solution indefinitely

  1. Development of a glass matrix for vitrification of sulphate bearing high level radioactive liquid waste

    International Nuclear Information System (INIS)

    Kaushik, C.P.; Mishra, R.K.; Thorat, Vidya; Ramchandran, M.; Amar Kumar; Ozarde, P.D.; Raj, Kanwar; Das, D.

    2004-07-01

    High level radioactive liquid waste (HLW) is generated during reprocessing of spent nuclear fuel. In the earlier reprocessing flow sheet ferrous sulphamate has been used for valancy adjustment of Pu from IV to III for effective separation. This has resulted in generation of HLW containing significance amount of sulphate. Internationally borosilicate glass matrix has been adopted for vitrification of HLW. The first Indian vitrification facility at Waste Immobilislition Plant (WIP), Tarapur a five component borosilicate matrix (SiO 2 :B 2 O 3 :Na 2 O : MnO : TiO 2 ) has been used for vitrification of waste. However at Trombay HLW contain significant amount of sulphate which is not compatible with standard borosilicate formulation. Extensive R and D efforts were made to develop a glass formulation which can accommodate sulphate and other constituents of HLW e.g., U, Al, Ca, etc. This report deals with development work of a glass formulations for immobilization of sulphate bearing waste. Different glass formulations were studied to evaluate the compatibility with respect to sulphate and other constituents as mentioned above. This includes sodium, lead and barium borosilicate glass matrices. Problems encountered in different glass matrices for containment of sulphate have also been addressed. A glass formulation based on barium borosilicate was found to be effective and compatible for sulphate bearing high level waste. (author)

  2. Determination of boron in nuclear materials at subppm levels by high pressure liquid chromatography (HPLC)

    International Nuclear Information System (INIS)

    Rao, Radhika M.; Aggarwal, S.K.

    2002-11-01

    Experiments were conducted for the determination of boron in U 3 O 8 powder, aluminium metal and milliQ water using dynamically modified Reversed Phase High Pressure Liquid Chromatography (RP-HPLC) and using two precolumn chromogenic agents viz. chromotropic acid and curcumin for complexing boron. The complex was separated from the excess of reagent and determined by HPLC. When present in subppm levels, chromotropic acid was used successfully only for determination boron in water samples. For determination of boron at subppm levels in uranium and aluminium samples, curcumin was used as the precolumn chromogenic agent. The boron curcumin complex (rosocyanin) was formed after extraction of boron with 2-ethyl-l, 3-hexane diol (EHD). The rosocyanin complex was then separated from excess curcumin by displacement chromatography. Linear calibration curves for boron amounts in the range of 0.02 μg to 0.5 μg were developed with correlation coefficients varying from 0.997 to 0.999 and were used for the determination of boron in aluminium and uranium samples. Precision of about 10% was achieved in samples containing less than 1 ppmw of boron. Detection limit of this method is 0.01 μg boron. (author)

  3. Association of plasma fatty acid composition with plasma irisin levels in normal weight and overweight/obese children.

    Science.gov (United States)

    Viitasalo, A; Ågren, J; Venäläinen, T; Pihlajamäki, J; Jääskeläinen, J; Korkmaz, A; Atalay, M; Lakka, T A

    2016-08-01

    Irisin has been suggested to protect against overweight. There are no previous data on the association of plasma fatty acid (FA) composition with plasma irisin. We studied the association of FA composition with plasma irisin in normal weight and overweight/obese children. This cross-sectional study included pre-pubertal children (388 normal weight children and 55 overweight/obese children); 6-9 years of age, taking part in the Physical Activity and Nutrition in Children Study. After an overnight fast, we measured plasma FA composition by gas chromatography and plasma irisin levels by enzyme-linked immunosorbent assay. Higher proportion of total monounsaturated fatty acids in plasma cholesteryl esters (CEs) (β = 0.139, P = 0.003) and phospholipids (PLs) (β = 0.147, P = 0.002) and lower proportion of total polyunsaturated fatty acids in plasma CE (β = -0.130, P = 0.006) and PL (β = -0.165, P overweight/obese children compared to normal weight children. Higher proportion of γ-linolenic acid (β = 0.324, P = 0.017) and lower proportion of linoleic acid (β = -0.397, P = 0.005) in plasma CE were related to higher plasma irisin level among overweight/obese children, indicating the direct association of estimated D6D activity in plasma CE (β = 0.343, P = 0.011) with plasma irisin. Furthermore, higher proportion of oleic acid in plasma CE (β = 0.345, P = 0.012) and PL (β = 0.292, P = 0.033) and higher proportion of adrenic acid (β = 0.366, P = 0.008) and docosapentaenoic acid (β = 0.351, P = 0.010) in plasma PL were associated with higher plasma irisin level among overweight/obese children. Metabolically unfavourable plasma FA profile was associated with higher plasma irisin level especially in overweight/obese children, suggesting that excess body fat might modulate these relationships. © 2015 World Obesity.

  4. Addition of liquid waste incineration capability to the INEL's low-level waste incinerator

    International Nuclear Information System (INIS)

    Steverson, E.M.; Clark, D.P.; McFee, J.N.

    1986-01-01

    A liquid waste system has recently been installed in the Waste Experimental Reduction Facility (WERF) incinerator at the Idaho National Engineering Laboratory (INEL). In this paper, aspects of the incineration system such as the components, operations, capabilities, capital cost, EPA permit requirements, and future plans are discussed. The principal objective of the liquid incineration system is to provide the capability to process hazardous, radioactively contaminated, non-halogenated liquid wastes. The system consists primarily of a waste feed system, instrumentation and controls, and a liquid burner, which were procured at a capital cost of $115,000

  5. Normalization of pH level and gastric mucosa after eradication of H. pylori in the remnant stomach.

    Science.gov (United States)

    Kato, Shunji; Matsukura, Norio; Matsuda, Noriko; Tsuchiya, Shinichi; Naito, Zenya; Tajiri, Takashi

    2008-12-01

    The Updated Sydney System (USS) is used to evaluate chronic gastritis and chronic atrophic gastritis (CAG) due to H. pylori infection. Here, we investigated USS scores and gastric juice pH levels in H. pylori infection-positive or -eradicated patients with remnant stomach after surgery. Gastric juice pH levels were measured using pH test-tape in 197 patients (112 H. pylori-positive and 85 H. pylori-negative after eradication) who had undergone distal gastrectomy and conventional H. pylori eradication therapy. In H. pylori infection-positive remnant stomach cases, gastric juice pH showed a reverse correlation with pepsinogen I/II ratio, and H. pylori infection-negative patients following eradication showed associations with the degree of atrophy and intestinal metaplasia at both the anastomosis and in the corpus. Further, pH levels in these patients were normalized time depending after the eradication in the remnant stomach. Eradication therapy for the remnant stomach contributes to the possible improvement of stomach conditions by controlling the pH level of gastric juice. This effect will be protective against the risk of secondary stomach carcinogenesis in the remnant stomach.

  6. Normal and reversed supramolecular chirality of insulin fibrils probed by vibrational circular dichroism at the protofilament level of fibril structure.

    Science.gov (United States)

    Kurouski, Dmitry; Dukor, Rina K; Lu, Xuefang; Nafie, Laurence A; Lednev, Igor K

    2012-08-08

    Fibrils are β-sheet-rich aggregates that are generally composed of several protofibrils and may adopt variable morphologies, such as twisted ribbons or flat-like sheets. This polymorphism is observed for many different amyloid associated proteins and polypeptides. In a previous study we proposed the existence of another level of amyloid polymorphism, namely, that associated with fibril supramolecular chirality. Two chiral polymorphs of insulin, which can be controllably grown by means of small pH variations, exhibit opposite signs of vibrational circular dichroism (VCD) spectra. Herein, using atomic force microscopy (AFM) and scanning electron microscopy (SEM), we demonstrate that indeed VCD supramolecular chirality is correlated not only by the apparent fibril handedness but also by the sense of supramolecular chirality from a deeper level of chiral organization at the protofilament level of fibril structure. Our microscopic examination indicates that normal VCD fibrils have a left-handed twist, whereas reversed VCD fibrils are flat-like aggregates with no obvious helical twist as imaged by atomic force microscopy or scanning electron microscopy. A scheme is proposed consistent with observed data that features a dynamic equilibrium controlled by pH at the protofilament level between left- and right-twist fibril structures with distinctly different aggregation pathways for left- and right-twisted protofilaments. Copyright © 2012 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  7. Evaporative light scattering detector in normal-phase high-performance liquid chromatography determination of FAME oxidation products.

    Science.gov (United States)

    Morales, Arturo; Marmesat, Susana; Dobarganes, M Carmen; Márquez-Ruiz, Gloria; Velasco, Joaquín

    2012-09-07

    The use of an ELS detector in NP-HPLC for quantitative analysis of oxidation products in FAME obtained from oils is evaluated in this study. The results obtained have shown that the ELS detector enables the quantitative determination of the hydroperoxides of oleic and linoleic acid methyl esters as a whole, and connected in series with a UV detector makes it possible to determine both groups of compounds by difference, providing useful complementary information. The limits of detection (LOD) and quantification (LOQ) found for hydroperoxides were respectively 2.5 and 5.7 μg mL⁻¹ and precision of quantitation expressed as coefficient of variation was lower than 10%. Due to a low sensitivity the ELS detector shows limitations to determine the low contents of secondary oxidation products in the direct analysis of FAME oxidized at low or moderate temperature. Analysis of FAME samples obtained either from high linoleic sunflower oil (HLSO) or high oleic sunflower oil (HOSO) and oxidized at 80 °C showed that only ketodienes formed from methyl linoleate can be determined in samples with relatively high oxidation, being the LOD and LOQ 0.2 and 0.4 mg/g FAME, respectively, at the analytical conditions applied. The ELS detector also enabled the determination of methyl cis-9,10-epoxystearate and methyl trans-9,10-epoxystearate, which were resolved at the chromatographic conditions applied. Results showed that these compounds, which are formed from methyl oleate, were not detected in the high-linoleic sample, but occurred at non-negligible levels in the oxidized FAME obtained from HOSO. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Low and medium level liquid waste processing at the new La Hague reprocessing plant

    International Nuclear Information System (INIS)

    Alexandre, D.

    1986-05-01

    Reprocessing of spent nuclear fuels produces low and medium activity liquid wastes. These radioactive wastes are decontamined before release in environment. The new effluent processing plant, which is being built at La Hague, is briefly described. Radionuclides are removed from liquid wastes by coprecipitation. The effluent is released after decantation and filtration. Insoluble sludges are conditioned in bitumen [fr

  9. On combining multi-normalization and ancillary measures for the optimal score level fusion of fingerprint and voice biometrics

    Science.gov (United States)

    Mohammed Anzar, Sharafudeen Thaha; Sathidevi, Puthumangalathu Savithri

    2014-12-01

    In this paper, we have considered the utility of multi-normalization and ancillary measures, for the optimal score level fusion of fingerprint and voice biometrics. An efficient matching score preprocessing technique based on multi-normalization is employed for improving the performance of the multimodal system, under various noise conditions. Ancillary measures derived from the feature space and the score space are used in addition to the matching score vectors, for weighing the modalities, based on their relative degradation. Reliability (dispersion) and the separability (inter-/intra-class distance and d-prime statistics) measures under various noise conditions are estimated from the individual modalities, during the training/validation stage. The `best integration weights' are then computed by algebraically combining these measures using the weighted sum rule. The computed integration weights are then optimized against the recognition accuracy using techniques such as grid search, genetic algorithm and particle swarm optimization. The experimental results show that, the proposed biometric solution leads to considerable improvement in the recognition performance even under low signal-to-noise ratio (SNR) conditions and reduces the false acceptance rate (FAR) and false rejection rate (FRR), making the system useful for security as well as forensic applications.

  10. Liquid ionizing radiaion detector

    International Nuclear Information System (INIS)

    deGaston, A.N.

    1979-01-01

    A normally nonconducting liquid such as liquid hydrocarbon is encased between a pair of electrodes in an enclosure so that when the liquid is subjected to ionizing radiation, the ion pairs so created measurably increase the conductivity of the fluid. The reduced impedance between the electrodes is detectable with a sensitive ohm-meter and indicates the amount of ionizing radiation. The enclosure, the electrodes and the fluid can be constructed of materials that make the response of the detector suitable for calibrating a large range of radiation energy levels. The detector is especially useful in medical applications where tissue equivalent X ray detectors are desired

  11. Water level response measurement in a steel cylindrical liquid storage tank using image filter processing under seismic excitation

    Science.gov (United States)

    Kim, Sung-Wan; Choi, Hyoung-Suk; Park, Dong-Uk; Baek, Eun-Rim; Kim, Jae-Min

    2018-02-01

    Sloshing refers to the movement of fluid that occurs when the kinetic energy of various storage tanks containing fluid (e.g., excitation and vibration) is continuously applied to the fluid inside the tanks. As the movement induced by an external force gets closer to the resonance frequency of the fluid, the effect of sloshing increases, and this can lead to a serious problem with the structural stability of the system. Thus, it is important to accurately understand the physics of sloshing, and to effectively suppress and reduce the sloshing. Also, a method for the economical measurement of the water level response of a liquid storage tank is needed for the exact analysis of sloshing. In this study, a method using images was employed among the methods for measuring the water level response of a liquid storage tank, and the water level response was measured using an image filter processing algorithm for the reduction of the noise of the fluid induced by light, and for the sharpening of the structure installed at the liquid storage tank. A shaking table test was performed to verify the validity of the method of measuring the water level response of a liquid storage tank using images, and the result was analyzed and compared with the response measured using a water level gauge.

  12. Treatment options of low level liquid waste of ETP origin by synthetic zeolites

    International Nuclear Information System (INIS)

    Singh, I.J.; Jain, Savita; Sathi Sasidharan, N.; Deshingkar, D.S.

    2001-08-01

    Mixture of synthetic zeolites, AR1, 4A and 13X of Indian origin were tested in a single fixed bed column operation for the treatment of low level liquid waste received at Effluents Treatment Plant (ETP) Trombay, under dynamic conditions. The mixed bed of zeolites was highly effective in decontaminating thousands of bed volumes of waste stream from radio cesium, radio strontium and gross beta gamma activity. High volume reduction factors, upwards of 10,000 are available in this process compared to less than 100 available with chemical precipitation process, currently followed. Containment of entrapped activity in zeolite bed was studied by solidifying them in Portland cement matrix as stable waste form. Incorporation of minerals like vermiculite as minor additive for improving the leaching characteristics of the final waste form was evaluated. Zeolite incorporated cement blocks were subjected to leach tests in distilled water for over 200 days to assess the incremental and cumulative leach rates of individual activity components. Leachability index of radio cesium and strontium were computed, which indicated the suitability of the matrix for safe shallow land burial. (author)

  13. Effect of phosphate ion on filtration characteristics of solids generated in simulated high level liquid waste

    International Nuclear Information System (INIS)

    Kondo, Y.

    1998-01-01

    The effect of phosphate ion on the filtration characteristics of solids generated in a high level liquid waste was experimentally examined. Addition of phosphate ion into the simulated HLLW induced the formation of phosphate such as zirconium phosphate and phosphomolybdic acid. The filtration rate of zirconium phosphate abruptly dropped in the midst of filtration because of a gel-cake formation on the filter surface. The denitration of the simulated HLLW contained zirconium phosphate improved the filterability of this gelatinous solid. The filtration rates of denitrated HLLW decreased with increase of the phosphate ion concentration, since the solids formed by denitration had irregular particle size and configuration in the simulated HLLW with phosphate ion. To increase the filtration rate of denitrated HLLW, a solid suspension filtration tester was designed. The solid-suspension accelerated the filtration rate only in the simulated HLLW with more than 1500 ppm phosphate ion concentration. Under this condition, the simple agitation can easily suspend the constituent solids of filter cake in the solution and a much higher filtration rate can be obtained because the filter cake is continuously swept from the filter surface by rotation of propellers. (authors)

  14. Design and application of discrete wavelet packet transform based multiresolution controller for liquid level system.

    Science.gov (United States)

    Paul, Rimi; Sengupta, Anindita

    2017-11-01

    A new controller based on discrete wavelet packet transform (DWPT) for liquid level system (LLS) has been presented here. This controller generates control signal using node coefficients of the error signal which interprets many implicit phenomena such as process dynamics, measurement noise and effect of external disturbances. Through simulation results on LLS problem, this controller is shown to perform faster than both the discrete wavelet transform based controller and conventional proportional integral controller. Also, it is more efficient in terms of its ability to provide better noise rejection. To overcome the wind up phenomenon by considering the saturation due to presence of actuator, anti-wind up technique is applied to the conventional PI controller and compared to the wavelet packet transform based controller. In this case also, packet controller is found better than the other ones. This similar work has been extended for analogous first order RC plant as well as second order plant also. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  15. A demonstration test of 4-group partitioning process with real high-level liquid waste

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Y.; Yamaguchi, I.; Fujiwara, T.; Koizumi, H.; Tachimori, S. [Japan Atomic Energy Research Institute, Tokai-Mura, Ibaraki-Ken (Japan)

    2000-07-01

    The demonstration test of 4-Group Partitioning Process with concentrated real high-level liquid waste (HLLW) was carried out in the Partitioning Test Facility installed in a hot cell. More than 99.998% of Am and Cm were extracted from the HLLW with the organic solvent containing 0.5 M DIDPA - 0.1 M TBP, and more than 99.98% of Am and Cm were back-extracted with 4 M nitric acid. Np and Pu were extracted simultaneously, and more than 99.93% of Np and more than 99.98% of Pu were back-extracted with oxalic acid. In the denitration step for the separation of Tc and platinum group metals, more than 90% of Rh and more than 97% of Pd were precipitated. About half of Ru were remained in the de-nitrated solution, but the remaining Ru were quantitatively precipitated by neutralization of the de-nitrated solution to pH 6.7. In the adsorption step, both Sr and Cs were separated effectively. Decontamination factors for Cs and Sr were more than 10{sup 6} and 10{sup 4} respectively in all effluent samples. (authors)

  16. Denitration of simulated high-level liquid wastes and selective removal of cesium with zeolites

    Energy Technology Data Exchange (ETDEWEB)

    Mimura, Hitoshi; Kanno, Takuji [Tohoku Univ., Sendai (Japan). Research Inst. of Mineral Dressing and Metallurgy; Kimura, Toshiya

    1982-03-01

    Denitration of high-level liquid wastes (HLW) from nuclear fuel reprocessing has been studied. Selective removal of Cs has been also examined with various types of zeolites. The following zeolites were used in this study; Na-synthetic mordenite (NaSM), Na-natural mordenite (NaNM), Na-natural clinoptilolite (NaCP) and H-synthetic mordenites (HSM). The effective denitration is found in the simulated HLW (15 components, 2N HNO/sub 3/ soln.) containing platinum group elements in the case of the addition of formic acid, and the pH of the solution shows the value of 5.4 when the excess formic acid ((HCOOH)/(HNO/sub 3/) = 2.0) was added. Platinum group elements may react as a catalyst for the decomposition of nitric acid and the excess formic acid. The break-through properties of NaSM column are poor for the simulated HLW, and the selective removal of Cs appears to be difficult. On the other hand, good results are obtained in the denitrated HLW, i.e., break-through capacity, total capacity and column utilization are 59.4 (meq./100 g zeolite), 147 (meq./100 g zeolite) and 40.4 (%), respectively. The break-through properties of NaSM and NaNM are superior to those of HSM. The break-through capacity and column utilization increase with an increase in column temperature.

  17. Determination of low-level acrylamide in drinking water by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Lucentini, Luca; Ferretti, Emanuele; Veschetti, Enrico; Achene, Laura; Turrio-Baldassarri, Luigi; Ottaviani, Massimo; Bogialli, Sara

    2009-01-01

    A simple and sensitive liquid chromatographic-tandem mass spectrometric (LC/MS/MS) method has been developed and validated to confirm and quantify acrylamide monomer (AA) in drinking water using [13C3] acrylamide as internal standard (IS). After a preconcentration by solid-phase extraction with spherical activated carbon, analytes were chromatographed on IonPac ICE-AS1 column (9 x 250 mm) under isocratic conditions using acetonitrile-water-0.1 M formic acid (43 + 52 + 5, v/v/v) as the mobile phase. Analysis was achieved using a triple-quadrupole mass analyzer equipped with a turbo ion spray interface. For confirmation and quantification of the analytes, MS data acquisition was performed in the multireaction monitoring mode, selecting 2 precursor ion to product ion transitions for both AA and IS. The method was validated for linearity, sensitivity, accuracy, precision, extraction efficiency, and matrix effect. Linearity in tap water was observed over the concentration range 0.1-2.0 microg/L. Limits of detection and quantification were 0.02 and 0.1 microg/L, respectively. Interday and intraday assays were performed across 3 validation levels (0.1, 0.5, and 1.5 microg/L). Accuracy (as mean recovery) ranged from 89.3 to 96.2% with relative standard deviation water in compliance with European Union and U.S. Environmental Protection Agency standards.

  18. Development of composite ion exchanger for separation of cesium from high level liquid waste

    International Nuclear Information System (INIS)

    Kumar, A.; Varshney, L.

    2010-01-01

    137 Cs (t 1/2 = 30 years) is one of the major radioisotope present in high level liquid waste (HLLW) generated during the reprocessing of nuclear fuel. Separation of 137 Cs from HLLW results in reduction of personal radiation exposure during the conditioning, transportation, storage and disposal. In addition, 137 Cs has enormous application as a radiation source in food preservation, sterilization of medical products, brachytherapy, blood irradiation, hygienization of sewage sludge etc. Ammonium molybdophosphate (AMP), an inorganic ion exchanger, has high selectivity and high exchange capacity for Cs. It exits as microcrystalline powder which is not amenable for column operation. ALIX is a composite material in which AMP is physically blended with inert polymeric substrate to improve its column property, exchange kinetics and increase its mechanical strength. The observed excellent properties of the composite are attributed to its engineered structure which is formed during its production. SEM analysis of ALIX shows that AMP crystals embedded in the cavities are not covered by the polymer which greatly enhances its availability for cesium exchange. The highly porous structure of the composite having 49% void volume facilitates faster kinetics of exchange of Cs from the aqueous phase and increased rate of reaction with alkali required during its dissolution

  19. Problems in the design and specification of containers for vitrified high-level liquid waste

    International Nuclear Information System (INIS)

    Corbet, A.D.W.; Hall, G.G.; Spiller, G.T.

    1976-01-01

    In the United Kingdom the growing problem of ensuring the safe storage of high-level liquid waste over long time scales has led to a policy for implementing solidification. A brief description is given of the HARVEST vitrification process, which is essentially a scaled-up version of the FINGAL process with increased throughput. The functional requirements of the container are considered. It must be made of a material which can be fabricated to a high standard. Diameters up to 600 mm for right circular cylindrical containers and 1200 mm for annular containers are contemplated. Computer aids for axisymmetric and three-dimensional heat transfer and stress analysis are identified. One example is given of the thermal profile for the cylindrical container in the furnace and another example for the annular container following an accident condition. Measured values are given for high temperature oxidation, emissivity and the short-term creep strength of various alloys. Corrosion in fresh water and sea water over long time periods and leaching of partially exposed solid waste are discussed and a conceptual package for sea bed disposal is described. The relative merits of the different methods of manufacture are pointed out and the paper concludes that HK-40 or better INCOLOY alloy 800L are suitable materials of construction. (author)

  20. Denitration of simulated high-level liquid wastes and selective removal of cesium with zeolites

    International Nuclear Information System (INIS)

    Mimura, Hitoshi; Kanno, Takuji; Kimura, Toshiya.

    1982-01-01

    Denitration of high-level liquid wastes (HLW) from nuclear fuel reprocessing has been studied. Selective removal of Cs has been also examined with various types of zeolites. The following zeolites were used in this study; Na-synthetic mordenite (NaSM), Na-natural mordenite (NaNM), Na-natural clinoptilolite (NaCP) and H-synthetic mordenites (HSM). The effective denitration is found in the simulated HLW (15 components, 2N HNO 3 soln.) containing platinum group elements in the case of the addition of formic acid, and the pH of the solution shows the value of 5.4 when the excess formic acid ([HCOOH]/[HNO 3 ] = 2.0) was added. Platinum group elements may react as a catalyst for the decomposition of nitric acid and the excess formic acid. The break-through properties of NaSM column are poor for the simulated HLW, and the selective removal of Cs appears to be difficult. On the other hand, good results are obtained in the denitrated HLW, i.e., break-through capacity, total capacity and column utilization are 59.4 (meq./100 g zeolite), 147 (meq./100 g zeolite) and 40.4 (%), respectively. The break-through properties of NaSM and NaNM are superior to those of HSM. The break-through capacity and column utilization increase with an increase in column temperature. (author)

  1. Evaluation of process alternatives for solidification of the West Valley high-level liquid wastes

    International Nuclear Information System (INIS)

    Holton, L.K.; Larson, D.E.

    1982-01-01

    The Department of Energy (DOE) established the West Valley Solidification Project (WVSP) in 1980. The project purpose is to demonstrate removal and solidification of the high-level liquid wastes (HLLW) presently stored in tanks at the Western New York Nuclear Service Center (WNYNSC), West Valley, New York. As part of this effort, the Pacific Northwest Laboratory (PNL) conducted a study to evaluate process alternatives for solidifcation of the WNYNSC wastes. Two process approaches for waste handling before solidification, together with solidification processes for four terminal and four interim waste forms, were considered. The first waste-handling approach, designated the salt/sludge separation process, involves separating the bulk of the nonradioactive nuclear waste constituents from the radioactive waste constituents, and the second waste-handling approach, designated the combined-waste process, involves no waste segregation prior to solidification. The processes were evaluated on the bases of their (1) readiness for plant startup by 1987, (2) relative technical merits, and (3) process cost. The study has shown that, based on these criteria, the salt/sludge separation process with a borosilicate glass waste form is preferred when producing a terminal waste form. It was also concluded that if an interim waste form is to be used, the preferred approach would be the combined waste process with a fused-salt waste form

  2. Leak testing plan for the Oak Ridge National Laboratory liquid low- level waste system (active tanks)

    International Nuclear Information System (INIS)

    Douglas, D.G.; Wise, R.F.; Starr, J.W.; Maresca, J.W. Jr.

    1992-06-01

    A leak testing plan for a portion of the Liquid Low-Level Waste (LLLW) system at the Oak Ridge National Laboratory (ORNL) is provided in the two volumes that form this document. This plan was prepared in response to the requirements of the Federal Facilities Agreement (FFA) between the US Department of Energy and two other agencies, the US Environmental Protection Agency (EPA) and the Tennessee Department of Environment and Conservation (TDEC). The effective date of this agreement was 1 January 1992. The LLLW system is an interconnected complex of tanks and pipelines. The FFA distinguishes four different categories of tank and pipeline systems within this complex: new systems (Category A), doubly contained systems (Category B), singly contained systems (Category C), and inactive systems (Category D). The FFA's specific requirements for leak testing of the Category C systems is addressed in this plan. The plan also addresses leak testing of the Category B portions of the LLLW system. Leak testing of the Category B components was brought into the plan to supplement the secondary containment design demonstration effort that is under way for these components

  3. Liquid low-level waste (LLLW) solidification at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Schultz, R.M.; Monk, T.H.; duMont, S.P.; Helms, R.E.; Keigan, M.V.; Morris, M.I.

    1987-01-01

    In general, the presentation describes the disposal of liquid, low-level (radioactive) waste (LLLW) by the hydrofracture process at Oak Ridge National Laboratory until 1984, when it was shut down due to regulatory concerns and operational anomalies. As a result of this, about 400,000 gallons of concentrated LLLW and 50,000 gallons of transuranic waste-bearing sludges have accumulated in the active, double-contained tank system which is reaching its operational capacity. A major initiative to develop an alternative means of LLLW treatment and disposal was begun about two years ago. This presentation summarizes the implementation strategy of the most likely process options. The strategy is being developed in two phases; a near-term flowsheet and a long-term or reference flowsheet. First, reliable and fully demonstrated commercial, cement solidification systems are being assessed for execution of an initial 50,000 gallon campaign in 1988. Second, development is under way to determine viable sludge separation, LLLW decontamination and solidification alternatives. A flowsheet analysis and cost study is being conducted by a consultant to ensure proper consideration of process developments at other sites. It is estimated that, depending upon funding requirements, it could take up to six years to implement the reference flowsheet

  4. Development of a micro liquid-level sensor for harsh environments using a periodic heating technique

    International Nuclear Information System (INIS)

    Hong, Jonggan; Kim, Dongsik; Chang, Young Soo

    2010-01-01

    This paper describes the development and testing of a novel micro thermal sensor for point sensing of lubrication oil level in industrial compressors. The results reported in this work can be applied to various harsh environments that feature high temperature/pressure, limited space and flow/vibration. The sensor employs an ac (alternating current) thermal technique with a single heating/sensing element. As the sensing scheme is based on the so-called three-omega method, the sensing signal is noise-resistant and hardly affected by flow in the liquid being measured. Experiments with DI water, ethanol and ethylene glycol confirm that the sensor performance is satisfactory under atmospheric pressure. Also, to mimic harsh conditions as in an industrial compressor, tests are performed in a pressure vessel containing R410A gas and polyvinylether lubrication oil under high temperatures and pressures. The results indicate that the sensitivity and response time of the developed sensor are appropriate for practical usage in harsh environments. As the sensor can be easily mass-produced at low cost using photolithography, it has strong potential for industrial applications

  5. Normalization of serum testosterone levels in patients treated with neoadjuvant hormonal therapy and three-dimensional conformal radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Padula, Gilbert D.A.; Zelefsky, Michael J.; Venkatraman, Ennapadam S.; Fuks, Zvi; Lee, Henry J.; Natale, Linda; Leibel, Steven A.

    2002-01-01

    Purpose: To determine the expected time to serum testosterone normalization after short-course neoadjuvant androgen deprivation therapy (NAAD) and three-dimensional conformal radiotherapy for patients with localized prostate cancer and to identify pretreatment predictors that correlated with the time to testosterone normalization. Methods: Between 1993 and 1999, 88 patients with localized prostate cancer, treated with NAAD and external beam radiotherapy, were prospectively monitored after treatment with sequential testosterone levels. NAAD was administered before and during the entire course of radiotherapy and discontinued at the end of treatment. The median duration of NAAD was 6 months. The actuarial rate of serum testosterone normalization from the end of treatment was evaluated, and the presence or absence of androgen deprivation-related symptoms was correlated with serum testosterone levels. Symptoms assessed included weight gain, loss of libido, breast tenderness, breast enlargement, hot flashes, and fatigue. Results: Serum testosterone levels returned to the normal range in 57 (65%) of the 88 patients and failed to normalize in 31 patients (35%). The median time to normalization was 18.3 months. The actuarial rate of normalization at 3, 6, 12, and 24 months was 10%, 26%, 38%, and 59%, respectively. In a multivariate analysis, a pretreatment testosterone level in the lower range of normal was the only variable that predicted for delayed testosterone normalization after NAAD (p=0.00047). Among 45 patients with information concerning androgen deprivation-related symptoms recorded 1 year after cessation of NAAD, 24 (53%) had normalized testosterone levels, but in 21 patients (47%), the levels had not yet returned to normal. At 1 year, only 1 (4%) of 24 patients whose testosterone level had returned to normal experienced NAAD-related symptoms compared with 14 (67%) of 21 patients who did not have normal testosterone levels (p<0.001). Conclusion: Testosterone

  6. LOW LEVEL LIQUID RADIOACTIVE WASTE TREATMENT AT MURMANSK, RUSSIA: FACILITY UPGRADE AND EXPANSION

    International Nuclear Information System (INIS)

    BOWERMAN, B.; CZAJKOWSKI, C.; DYER, R.S.; SORLIE, A.

    2000-01-01

    Today there exist many almost overfilled storage tanks with liquid radioactive waste in the Russian Federation. This waste was generated over several years by the civil and military utilization of nuclear power. The current waste treatment capacity is either not available or inadequate. Following the London Convention, dumping of the waste in the Arctic seas is no longer an alternative. Waste is being generated from today's operations, and large volumes are expected to be generated from the dismantling of decommissioned nuclear submarines. The US and Norway have an ongoing co-operation project with the Russian Federation to upgrade and expand the capacity of a treatment facility for low level liquid waste at the RTP Atomflot site in Murmansk. The capacity will be increased from 1,200 m 3 /year to 5,000 m 3 /year. The facility will also be able to treat high saline waste. The construction phase will be completed the first half of 1998. This will be followed by a start-up and a one year post-construction phase, with US and Norwegian involvement for the entire project. The new facility will consist of 9 units containing various electrochemical, filtration, and sorbent-based treatment systems. The units will be housed in two existing buildings, and must meet more stringent radiation protection requirements that were not enacted when the facility was originally designed. The US and Norwegian technical teams have evaluated the Russian design and associated documentation. The Russian partners send monthly progress reports to US and Norway. Not only technical issues must be overcome but also cultural differences resulting from different methods of management techniques. Six to eight hour time differentials between the partners make real time decisions difficult and relying on electronic age tools becomes extremely important. Language difficulties is another challenge that must be solved. Finding a common vocabulary, and working through interpreters make the process very

  7. LOW LEVEL LIQUID RADIOACTIVE WASTE TREATMENT AT MURMANSK, RUSSIA: FACILITY UPGRADE AND EXPANSION

    Energy Technology Data Exchange (ETDEWEB)

    BOWERMAN,B.; CZAJKOWSKI,C.; DYER,R.S.; SORLIE,A.

    2000-03-01

    Today there exist many almost overfilled storage tanks with liquid radioactive waste in the Russian Federation. This waste was generated over several years by the civil and military utilization of nuclear power. The current waste treatment capacity is either not available or inadequate. Following the London Convention, dumping of the waste in the Arctic seas is no longer an alternative. Waste is being generated from today's operations, and large volumes are expected to be generated from the dismantling of decommissioned nuclear submarines. The US and Norway have an ongoing co-operation project with the Russian Federation to upgrade and expand the capacity of a treatment facility for low level liquid waste at the RTP Atomflot site in Murmansk. The capacity will be increased from 1,200 m{sup 3}/year to 5,000 m{sup 3} /year. The facility will also be able to treat high saline waste. The construction phase will be completed the first half of 1998. This will be followed by a start-up and a one year post-construction phase, with US and Norwegian involvement for the entire project. The new facility will consist of 9 units containing various electrochemical, filtration, and sorbent-based treatment systems. The units will be housed in two existing buildings, and must meet more stringent radiation protection requirements that were not enacted when the facility was originally designed. The US and Norwegian technical teams have evaluated the Russian design and associated documentation. The Russian partners send monthly progress reports to US and Norway. Not only technical issues must be overcome but also cultural differences resulting from different methods of management techniques. Six to eight hour time differentials between the partners make real time decisions difficult and relying on electronic age tools becomes extremely important. Language difficulties is another challenge that must be solved. Finding a common vocabulary, and working through interpreters make the

  8. A Study on the Model of Detecting the Liquid Level of Sealed Containers Based on Kirchhoff Approximation Theory

    Directory of Open Access Journals (Sweden)

    Bin Zhang

    2017-06-01

    Full Text Available By simulating the sound field of a round piston transducer with the Kirchhoff integral theorem and analyzing the shape of ultrasound beams and propagation characteristics in a metal container wall, this study presents a model for calculating the echo sound pressure by using the Kirchhoff paraxial approximation theory, based on which and according to different ultrasonic impedance between gas and liquid media, a method for detecting the liquid level from outside of sealed containers is proposed. Then, the proposed method is evaluated through two groups of experiments. In the first group, three kinds of liquid media with different ultrasonic impedance are used as detected objects; the echo sound pressure is calculated by using the proposed model under conditions of four sets of different wall thicknesses. The changing characteristics of the echo sound pressure in the entire detection process are analyzed, and the effects of different ultrasonic impedance of liquids on the echo sound pressure are compared. In the second group, taking water as an example, two transducers with different radii are selected to measure the liquid level under four sets of wall thickness. Combining with sound field characteristics, the influence of different size transducers on the pressure calculation and detection resolution are discussed and analyzed. Finally, the experimental results indicate that measurement uncertainly is better than ±5 mm, which meets the industrial inspection requirements.

  9. A Study on the Model of Detecting the Liquid Level of Sealed Containers Based on Kirchhoff Approximation Theory.

    Science.gov (United States)

    Zhang, Bin; Song, Wen-Ai; Wei, Yue-Juan; Zhang, Dong-Song; Liu, Wen-Yi

    2017-06-15

    By simulating the sound field of a round piston transducer with the Kirchhoff integral theorem and analyzing the shape of ultrasound beams and propagation characteristics in a metal container wall, this study presents a model for calculating the echo sound pressure by using the Kirchhoff paraxial approximation theory, based on which and according to different ultrasonic impedance between gas and liquid media, a method for detecting the liquid level from outside of sealed containers is proposed. Then, the proposed method is evaluated through two groups of experiments. In the first group, three kinds of liquid media with different ultrasonic impedance are used as detected objects; the echo sound pressure is calculated by using the proposed model under conditions of four sets of different wall thicknesses. The changing characteristics of the echo sound pressure in the entire detection process are analyzed, and the effects of different ultrasonic impedance of liquids on the echo sound pressure are compared. In the second group, taking water as an example, two transducers with different radii are selected to measure the liquid level under four sets of wall thickness. Combining with sound field characteristics, the influence of different size transducers on the pressure calculation and detection resolution are discussed and analyzed. Finally, the experimental results indicate that measurement uncertainly is better than ±5 mm, which meets the industrial inspection requirements.

  10. Proceedings of the international seminar on chemistry and process engineering for high-level liquid waste solidification

    International Nuclear Information System (INIS)

    Odoj, R.; Merz, E.

    1981-06-01

    The proceedings record a very distinct phase of the chemistry and process engineering for high-level liquid waste solidification in the past years. The main purpose is to provide solutions which guarantee sufficient safe and economically acceptable measure causing no adverse consequence to man and his environment. (DG)

  11. Fiber-optic liquid level monitoring system using microstructured polymer fiber Bragg grating array sensors: performance analysis

    DEFF Research Database (Denmark)

    Marques, C. A. F.; Pospori, A.; Saez-Rodriguez, D.

    2015-01-01

    to interrogate liquid level by measuring the strain induced in each mPOFBG embedded in a silicone rubber (SR) diaphragm, which deforms due to hydrostatic pressure variations. The sensor exhibits a highly linear response over the sensing range, a good repeatability, and a high resolution. The sensitivity...

  12. Method development for liquid chromatographic/triple quadrupole mass spectrometric analysis of trace level perfluorocarboxylic acids in articles of commerce

    Science.gov (United States)

    An analytical method to identify and quantify trace levels of C5 to C12 perfluorocarboxylic acids (PFCAs) in articles of commerce (AOC) is developed and rigorously validated. Solid samples were extracted in methanol, and liquid samples were diluted with a solvent consisting of 60...

  13. Some case studies of skewed (and other ab-normal) data distributions arising in low-level environmental research

    International Nuclear Information System (INIS)

    Currie, L.A.

    2001-01-01

    Three general classes of skewed data distributions have been encountered in research on background radiation, chemical and radiochemical blanks, and low levels of 85 Kr and 14 C in the atmosphere and the cryosphere. The first class of skewed data can be considered to be theoretically, or fundamentally skewed. It is typified by the exponential distribution of inter-arrival times for nuclear counting events for a Poisson process. As part of a study of the nature of low-level (anti-coincidence) Geiger- Mueller counter background radiation, tests were performed on the Poisson distribution of counts, the uniform distribution of arrival times, and the exponential distribution of inter-arrival times. The real laboratory system, of course, failed the (inter-arrival time) test - for very interesting reasons, linked to the physics of the measurement process. The second, computationally skewed, class relates to skewness induced by non-linear transformations. It is illustrated by non-linear concentration estimates from inverse calibration, and bivariate blank corrections for low-level 14 C- 12 C aerosol data that led to highly asymmetric uncertainty intervals for the biomass carbon contribution to urban ''soot''. The third, environmentally skewed, data class relates to a universal problem for the detection of excursions above blank or baseline levels: namely, the widespread occurrence of ab-normal distributions of environmental and laboratory blanks. This is illustrated by the search for fundamental factors that lurk behind skewed frequency distributions of sulfur laboratory blanks and 85 Kr environmental baselines, and the application of robust statistical procedures for reliable detection decisions in the face of skewed isotopic carbon procedural blanks with few degrees of freedom. (orig.)

  14. Some case studies of skewed (and other ab-normal) data distributions arising in low-level environmental research.

    Science.gov (United States)

    Currie, L A

    2001-07-01

    Three general classes of skewed data distributions have been encountered in research on background radiation, chemical and radiochemical blanks, and low levels of 85Kr and 14C in the atmosphere and the cryosphere. The first class of skewed data can be considered to be theoretically, or fundamentally skewed. It is typified by the exponential distribution of inter-arrival times for nuclear counting events for a Poisson process. As part of a study of the nature of low-level (anti-coincidence) Geiger-Muller counter background radiation, tests were performed on the Poisson distribution of counts, the uniform distribution of arrival times, and the exponential distribution of inter-arrival times. The real laboratory system, of course, failed the (inter-arrival time) test--for very interesting reasons, linked to the physics of the measurement process. The second, computationally skewed, class relates to skewness induced by non-linear transformations. It is illustrated by non-linear concentration estimates from inverse calibration, and bivariate blank corrections for low-level 14C-12C aerosol data that led to highly asymmetric uncertainty intervals for the biomass carbon contribution to urban "soot". The third, environmentally, skewed, data class relates to a universal problem for the detection of excursions above blank or baseline levels: namely, the widespread occurrence of ab-normal distributions of environmental and laboratory blanks. This is illustrated by the search for fundamental factors that lurk behind skewed frequency distributions of sulfur laboratory blanks and 85Kr environmental baselines, and the application of robust statistical procedures for reliable detection decisions in the face of skewed isotopic carbon procedural blanks with few degrees of freedom.

  15. High-fructose corn syrup and sucrose have equivalent effects on energy-regulating hormones at normal human consumption levels.

    Science.gov (United States)

    Yu, Zhiping; Lowndes, Joshua; Rippe, James

    2013-12-01

    Intake of high-fructose corn syrup (HFCS) has been suggested to contribute to the increased prevalence of obesity, whereas a number of studies and organizations have reported metabolic equivalence between HFCS and sucrose. We hypothesized that HFCS and sucrose would have similar effects on energy-regulating hormones and metabolic substrates at normal levels of human consumption and that these values would not change over a 10-week, free-living period at these consumption levels. This was a randomized, prospective, double-blind, parallel group study in which 138 adult men and women consumed 10 weeks of low-fat milk sweetened with either HFCS or sucrose at levels of the 25th, 50th, and 90th percentile population consumption of fructose (the equivalent of 40, 90, or 150 g of sugar per day in a 2000-kcal diet). Before and after the 10-week intervention, 24-hour blood samples were collected. The area under the curve (AUC) for glucose, insulin, leptin, active ghrelin, triglyceride, and uric acid was measured. There were no group differences at baseline or posttesting for all outcomes (interaction, P > .05). The AUC response of glucose, active ghrelin, and uric acid did not change between baseline and posttesting (P > .05), whereas the AUC response of insulin (P < .05), leptin (P < .001), and triglyceride (P < .01) increased over the course of the intervention when the 6 groups were averaged. We conclude that there are no differences in the metabolic effects of HFCS and sucrose when compared at low, medium, and high levels of consumption. © 2013 Elsevier Inc. All rights reserved.

  16. Energy information needs for U. S. state-level policy making: Minimal data requirements during normal and emergency periods

    Energy Technology Data Exchange (ETDEWEB)

    Barkenbus, J.N.; Leff, H.S.

    1983-01-01

    Since the oil embargo of 1973, state governments have increased their efforts to track and understand energy flows within their boundaries. There is a commonly perceived need to comprehend the status of present and expected future energy availability, demand, and price and to be prepared to exercise responsible and effective management during energy emergencies. This responsibility has brought with it new needs for accurate and timely state-level information on energy transactions and the external parameters that effect energy availability and disposition. What energy data are needed by a state, regardless of its idiosyncracies, during both normal and energy emergency periods, and to what extent are these data available now. The authors find that needed ongoing (core) data are only partially available at present, and that emergency data can be obtained only with a carefully planned monitoring program that can be fitted to specific emergency conditions. Overall, this paper provides a realistic assessment of the state-level energy data needed to provide state policy makers with sufficient information to make considered judgments.

  17. Energy-information needs for US state-level policy making: minimal data requirements during normal and emergency periods

    Energy Technology Data Exchange (ETDEWEB)

    Barkenbus, J.N.; Leff, H.S.

    1983-01-01

    Since the oil embargo of 1973, state governments have increased their efforts to track and understand energy flows within their boundaries. There is a commonly perceived need to comprehend the status of present and expected future energy availability, demand, and price and to be prepared to exercise responsible and effective management during energy emergencies. This responsibility has brought with it new needs for accurate and timely state-level information on energy transactions and the external parameters that effect energy availability and disposition. Hence, we ask: what energy data are needed by a state, regardless of its idiosyncracies, during both normal and energy emergency periods, and to what extent are these data available now. We find that needed ongoing (core) data are only partially available at present, and that emergency data can be obtained only with a carefully planned monitoring program that can be fitted to specific emergency conditions. Overall, this paper provides a realistic assessment of the state-level energy data needed to provide state policy makers with sufficient information to make considered judgments. 7 references, 6 tables.

  18. Ionic liquids. Combination of combustion calorimetry with high-level quantum chemical calculations for deriving vaporization enthalpies.

    Science.gov (United States)

    Emel'yanenko, Vladimir N; Verevkin, Sergey P; Heintz, Andreas; Schick, Christoph

    2008-07-10

    In this work, the molar enthalpies of formation of the ionic liquids [C2MIM][NO3] and [C4MIM][NO3] were measured by means of combustion calorimetry. The molar enthalpy of fusion of [C2MIM][NO3] was measured using differential scanning calorimetry. Ab initio calculations of the enthalpy of formation in the gaseous phase have been performed for the ionic species using the G3MP2 theory. We have used a combination of traditional combustion calorimetry with modern high-level ab initio calculations in order to obtain the molar enthalpies of vaporization of a series of the ionic liquids under study.

  19. An efficient approach for differentiating Alzheimer's disease from normal elderly based on multicenter MRI using gray-level invariant features.

    Directory of Open Access Journals (Sweden)

    Muwei Li

    Full Text Available Machine learning techniques, along with imaging markers extracted from structural magnetic resonance images, have been shown to increase the accuracy to differentiate patients with Alzheimer's disease (AD from normal elderly controls. Several forms of anatomical features, such as cortical volume, shape, and thickness, have demonstrated discriminative capability. These approaches rely on accurate non-linear image transformation, which could invite several nuisance factors, such as dependency on transformation parameters and the degree of anatomical abnormality, and an unpredictable influence of residual registration errors. In this study, we tested a simple method to extract disease-related anatomical features, which is suitable for initial stratification of the heterogeneous patient populations often encountered in clinical data. The method employed gray-level invariant features, which were extracted from linearly transformed images, to characterize AD-specific anatomical features. The intensity information from a disease-specific spatial masking, which was linearly registered to each patient, was used to capture the anatomical features. We implemented a two-step feature selection for anatomic recognition. First, a statistic-based feature selection was implemented to extract AD-related anatomical features while excluding non-significant features. Then, seven knowledge-based ROIs were used to capture the local discriminative powers of selected voxels within areas that were sensitive to AD or mild cognitive impairment (MCI. The discriminative capability of the proposed feature was measured by its performance in differentiating AD or MCI from normal elderly controls (NC using a support vector machine. The statistic-based feature selection, together with the knowledge-based masks, provided a promising solution for capturing anatomical features of the brain efficiently. For the analysis of clinical populations, which are inherently heterogeneous

  20. Comparison of low-normal and high-normal IGF-1 target levels during growth hormone replacement therapy : A randomized clinical trial in adult growth hormone deficiency

    NARCIS (Netherlands)

    van Bunderen, Christa C; Lips, Paul; Kramer, Mark H H; Drent, Madeleine L

    BACKGROUND: Current guidelines state that the goals of growth hormone (GH) therapy in adults should be an appropriate clinical response, avoidance of side effects, and an IGF-1 value within the age-adjusted reference range. There are no published studies on the target level for IGF-1 that offer

  1. Liquidity implications of a commitment period reserve at national and global levels

    International Nuclear Information System (INIS)

    Haites, Erik; Missfeldt, Fanny

    2004-01-01

    The Kyoto Protocol, if it enters into force, will establish international emissions trading for quota that can be used for compliance with Protocol commitments. Concern that the non-compliance regime might not be sufficient to deter overselling led to adoption of the commitment period reserve requirement. This paper analyses the commitment period reserve in terms of (a) the liquidity of the international emissions trading market, and (b) international liquidity for domestic emissions trading programs in Annex B countries. The liquidity of the international greenhouse gas emissions trading market is measured as the sum of the quota surplus to the reserve requirement of net seller countries divided by the average annual assigned amount of all Annex B Parties and by the BAU emissions of Annex B Parties. Both measures are calculated using both the average values across 500 projections of future emissions and the values that yield the lowest liquidity (lowest reserves, highest emissions). Even the lowest estimates indicate liquidity comparable to that of the existing emissions trading programs. In addition, the international liquidity for domestic emissions trading programs with the commitment period reserve is likely to be comparable to or better than that of existing emissions trading markets, even under conservative assumptions

  2. Effect of dopamine, dopamine D-1 and D-2 receptor modulation on ACTH and cortisol levels in normal men and women

    DEFF Research Database (Denmark)

    Boesgaard, S; Hagen, C; Andersen, A N

    1990-01-01

    The regulation of the hypothalamic-pituitary-adrenal axis by dopamine is not fully understood. Therefore, we have studied the effect of dopamine, metoclopramide, a D-2 receptor antagonist, and fenoldopam, a specific D-1 receptor agonist, on ACTH and cortisol levels in normal subjects. Normal women...

  3. Normal-phase liquid chromatography retention behavior of polycyclic aromatic sulfur heterocycles and alkyl-substituted polycyclic aromatic sulfur heterocycle isomers on an aminopropyl stationary phase.

    Science.gov (United States)

    Wilson, Walter B; Hayes, Hugh V; Sander, Lane C; Campiglia, Andres D; Wise, Stephen A

    2018-02-01

    Retention indices for 67 polycyclic aromatic sulfur heterocycles (PASHs) and 80 alkyl-substituted PASHs were determined using normal-phase liquid chromatography (NPLC) on an aminopropyl (NH 2 ) stationary phase. The retention behavior of PASH on the NH 2 phase is correlated with the number of aromatic carbon atoms and two structural characteristics have a significant influence on their retention: non-planarity (thickness, T) and the position of the sulfur atom in the bay-region of the structure. Correlations between solute retention on the NH 2 phase and T of PASHs were investigated for three cata-condensed (cata-) PASH isomer groups: (a) 13 four-ring molecular mass (MM) 234 Da cata-PASHs, (b) 20 five-ring MM 284 Da cata-PASHs, and (c) 12 six-ring MM 334 Da cata-PASHs. Correlation coefficients ranged from r = -0.49 (MM 234 Da) to r = -0.65 (MM 334 Da), which were significantly lower than structurally similar PAH isomer groups (r = -0.70 to r = -0.99). The NPLC retention behavior of the PASHs are compared to similar results for PAHs.

  4. Sample handling and contamination encountered when coupling offline normal phase high performance liquid chromatography fraction collection of petroleum samples to Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Oro, Nicole E; Whittal, Randy M; Lucy, Charles A

    2012-09-05

    Normal phase high performance liquid chromatography (HPLC) is used to separate a gas oil petroleum sample, and the fractions are collected offline and analyzed on a high resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (FT-ICR MS). The separation prior to MS analysis dilutes the sample significantly; therefore the fractions need to be prepared properly to achieve the best signal possible. The methods used to prepare the HPLC fractions for MS analysis are described, with emphasis placed on increasing the concentration of analyte species. The dilution effect also means that contamination in the MS spectra needs to be minimized. The contamination from molecular sieves, plastics, soap, etc. and interferences encountered during the offline fraction collection process are described and eliminated. A previously unreported MS contamination of iron formate clusters with a 0.8 mass defect in positive mode electrospray is also described. This interference resulted from the stainless steel tubing in the HPLC system. Contamination resulting from what has tentatively been assigned as palmitoylglycerol and stearoylglycerol was also observed; these compounds have not previously been reported as contaminant peaks. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Liquid level and temperature sensing by using dual-wavelength fiber laser based on multimode interferometer and FBG in parallel

    Science.gov (United States)

    Sun, Chunran; Dong, Yue; Wang, Muguang; Jian, Shuisheng

    2018-03-01

    The detection of liquid level and temperature based on a fiber ring cavity laser sensing configuration is presented and demonstrated experimentally. The sensing head contains a fiber Bragg grating (FBG) and a single-mode-cladding-less-single-mode multimode interferometer, which also functions as wavelength-selective components of the fiber laser. When the liquid level or temperature is applied on the sensing head, the pass-band peaks of both multimode interference (MMI) filter and FBG filter vary and the two output wavelengths of the laser shift correspondingly. In the experiment, the corresponding sensitivities of the liquid level with four different refractive indices (RI) in the deep range from 0 mm to 40 mm are obtained and the sensitivity enhances with the RI of the liquid being measured. The maximum sensitivity of interferometer is 106.3 pm/mm with the RI of 1.391. For the temperature measurement, a sensitivity of 10.3 pm/°C and 13.8 pm/°C are achieved with the temperature ranging from 0 °C to 90 °C corresponding to the two lasing wavelengths selective by the MMI filter and FBG, respectively. In addition, the average RI sensitivity of 155.77 pm/mm/RIU is also obtained in the RI range of 1.333-1.391.

  6. Development studies for the treatment of ORNL low-level liquid waste

    International Nuclear Information System (INIS)

    Campbell, D.O.; Lee, D.D.; Dillow, T.A.

    1991-11-01

    An experimental program is under way to investigate potential separation methods for application to specific problems relating to the management of low-level liquid wastes (LLLWs) at ORNL. This report summarizes experimental results that were acquired during fiscal year 1990 and have not been previously reported elsewhere. Measurements are presented for cesium and strontium removal from simulated high-salt waste compositions, using both inorganic ion- exchange sorbents and organic ion-exchange resins, and for one experiment with actual LLLW supernate solution from Melton Valley Storage Tank W-26, using inorganic sorbents. The purpose of the study was to acquire an extensive data base to support the development of flowsheets for decontamination of the LLLW currently stored at ORNL. Experimental measurements with inorganic ion exchangers focused on batch separations of cesium using several transition-metal hexacyanoferrate(2) compositions (ferrocyanides) and of strontium using titanium oxide-based sorbents. Cesium distribution coefficients in the range of 1 x 10 6 were generally observed with nickel and cobalt ferrocyanides at pH values ≤11, yielding DFs of about 100 with 100 ppm sorbent in a single-stage batch separation. Most organic ion-exchange resins are not very effective for cesium removal from such high salt concentrations, but a new resorcinol-based resin developed at the Savannah River Site was found to be considerably superior to any other such material tested. Several chelating resins were effective for removing strontium from the waste simulants. An ion-exchange column test successfully demonstrated the simultaneous removal of both cesium and strontium from a waste simulant solution

  7. Surveillance and maintenance plan for the inactive liquid low-level waste tanks at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    1994-11-01

    ORNL has a total of 54 inactive liquid low-level waste (ILLLW) tanks. In the past, these tanks were used to contain radioactive liquid wastes from various research programs, decontamination operations, and reactor operations. The tanks have since been removed from service for various reasons; the majority were retired because of their age, some due to integrity compromises, and others because they did not meet the current standards set by the Federal Facilities Agreement (FFA). Many of the tanks contain residual radioactive liquids and/or sludges. Plans are to remediate all tanks; however, until remediation of each tank, this Surveillance and Maintenance (S ampersand M) Plan will be used to monitor the safety and inventory containment of these tanks

  8. Determination of Np, Pu and Am in high level radioactive waste with extraction-liquid scintillation counting

    International Nuclear Information System (INIS)

    Yang Dazhu; Zhu Yongjun; Jiao Rongzhou

    1994-01-01

    A new method for the determination of transuranium elements, Np, Pu and Am with extraction-liquid scintillation counting has been studied systematically. Procedures for the separation of Pu and Am by HDEHP-TRPO extraction and for the separation of Np by TTA-TiOA extraction have been developed, by which the recovery of Np, Pu and Am is 97%, 99% and 99%, respectively, and the decontamination factors for the major fission products ( 90 Sr, 137 Cs etc.) are 10 4 -10 6 . Pulse shape discrimination (PSD) technique has been introduced to liquid scintillation counting, by which the counting efficiency of α-activity is >99% and the rejection of β-counts is >99.95%. This new method, combining extraction and pulse shape discrimination with liquid scintillation technique, has been successfully applied to the assay of Np, Pu and Am in high level radioactive waste. (author) 7 refs.; 7 figs.; 4 tabs

  9. The value of CT measurement of normal human mandible, hyoid and the airway area at the hyoid level

    International Nuclear Information System (INIS)

    Chen Changliang; Zhang Jia; Ge Pingjiang; Zhang Siyi

    2004-01-01

    Objective: To determine the normal value and clinical significance of the lengths and angles of both mandible and hyoid, and their relationship with cervical vertebra as well as the transverse area of the airway at the hyoid level using CT. Methods: Several lines and angles on the CT images were measured in 68 normal subjects. Line A was the length between both free ends of the mandible; line B was the distance from the body of the mandible to line A; Line C was the distance from line A to the anterior aspect of the cervical vertebra. α 1 was the angle between the middle of mandible body and its two free ends. Line a was the distance between two free ends of greater horn of hyoid bone. Line b was the distance from hyoid to line a. Line c was the distance from line a to the cervical vertebra. α 2 was the angle between the middle of hyoid body and its two free ends. S stood for the area of the airway at the hyoid level. SPSS 11.5 statistical analysis package was used to analyze the results. Results: The average and median distance/angle of various measurements were as follows: line A was (89.28±5.90) mm and 88.70 mm, line B was (62.61±5.78) mm and 62.50 mm, line C was (9.29±3.29) mm and 4.20 mm, α 1 was (71.25±6.77) degree and 71.05 degree, line a was (38.69 ± 6.07) mm and 39.90 mm, line b was (28.79 ± 4.37) mm and 28.50 mm, line c was (1.91 ± 3.03) mm and 1.75 mm, α 2 was (68.47 ± 15.71) degree and 66.95 degree. The average S was (436.14 ± 160.37) mm 2 and median was 431.75 mm 2 . Conclusion: It is easy to measure the three lines and the two angles of mandible and hyoid. The measurement is of vital importance in the diagnosis and treatment for obstructive sleep apnea syndrome

  10. Emergence of liquid crystalline order in the lowest Landau level of a quantum Hall system with internal anisotropy

    Science.gov (United States)

    Ciftja, Orion

    2018-05-01

    It has now become evident that interplay between internal anisotropy parameters (such as electron mass anisotropy and/or anisotropic coupling of electrons to the substrate) and electron-electron correlation effects can create a rich variety of possibilities especially in quantum Hall systems. The electron mass anisotropy or material substrate effects (for example, the piezoelectric effect in GaAs) can lead to an effective anisotropic interaction potential between electrons. For lack of knowledge of realistic ab-initio potentials that may describe such effects, we adopt a phenomenological approach and assume that an anisotropic Coulomb interaction potential mimics the internal anisotropy of the system. In this work we investigate the emergence of liquid crystalline order at filling factor ν = 1/6 of the lowest Landau level, a state very close to the point where a transition from the liquid to the Wigner solid happens. We consider small finite systems of electrons interacting with an anisotropic Coulomb interaction potential and study the energy stability of an anisotropic liquid crystalline state relative to its isotropic Fermi-liquid counterpart. Quantum Monte Carlo simulation results in disk geometry show stabilization of liquid crystalline order driven by an anisotropic Coulomb interaction potential at all values of the interaction anisotropy parameter studied.

  11. Management of Discharge of Low Level Liquid Radioactive Waste Generated in Medical, Educational, Research and Industrial Facilities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-07-15

    Although published information on management technologies suitable for radioactive effluents is readily available, smaller facilities such as hospitals, universities and research laboratories in some countries can benefit from more detailed guidance on identifying optimal arrangements for effectively managing their radioactive liquid effluents. A wide range of circumstances exist globally, given that the generation of radioactive liquid effluents may be regular or irregular, and the liquid effluents may be suitable for direct discharge to the environment, or may require a period of decay storage prior to discharge. Countries typically fit into one of the four following categories with respect to the status of their arrangements for the management of radioactive liquid effluents: (1) The country does not have sufficient technical, regulatory and organizational infrastructure to effectively manage its radioactive liquid effluents; (2) The country's technical infrastructure for effectively managing its radioactive liquid effluents is almost sufficient, but it is not supported by an acceptable level of regulatory and organizational capacity (e.g. legal infrastructure, administrative infrastructure); (3) The country has sufficient technical, regulatory and organizational capacity, but it is known that the application of the requirements for proper management of radioactive liquid effluents is, in many cases, not being carried out to the standard indicated by official reports; (4) The country has well developed and established regulatory and organizational capacity, which is complemented by an acceptable level of relevant technical infrastructure such that the radioactive liquid effluents can be properly managed. Facilities, as well as countries, in the first three categories will find information in this publication to assist their further development. Even countries that already have the necessary infrastructure to properly manage their liquid radioactive effluents may

  12. Management of Discharge of Low Level Liquid Radioactive Waste Generated in Medical, Educational, Research and Industrial Facilities

    International Nuclear Information System (INIS)

    2013-07-01

    Although published information on management technologies suitable for radioactive effluents is readily available, smaller facilities such as hospitals, universities and research laboratories in some countries can benefit from more detailed guidance on identifying optimal arrangements for effectively managing their radioactive liquid effluents. A wide range of circumstances exist globally, given that the generation of radioactive liquid effluents may be regular or irregular, and the liquid effluents may be suitable for direct discharge to the environment, or may require a period of decay storage prior to discharge. Countries typically fit into one of the four following categories with respect to the status of their arrangements for the management of radioactive liquid effluents: (1) The country does not have sufficient technical, regulatory and organizational infrastructure to effectively manage its radioactive liquid effluents; (2) The country's technical infrastructure for effectively managing its radioactive liquid effluents is almost sufficient, but it is not supported by an acceptable level of regulatory and organizational capacity (e.g. legal infrastructure, administrative infrastructure); (3) The country has sufficient technical, regulatory and organizational capacity, but it is known that the application of the requirements for proper management of radioactive liquid effluents is, in many cases, not being carried out to the standard indicated by official reports; (4) The country has well developed and established regulatory and organizational capacity, which is complemented by an acceptable level of relevant technical infrastructure such that the radioactive liquid effluents can be properly managed. Facilities, as well as countries, in the first three categories will find information in this publication to assist their further development. Even countries that already have the necessary infrastructure to properly manage their liquid radioactive effluents may

  13. Hair removal in hirsute women with normal testosterone levels: a randomized controlled trial of long-pulsed diode laser vs. intense pulsed light

    DEFF Research Database (Denmark)

    Haak, C S; Jensen, Pernille Nymann; Pedersen, A T

    2010-01-01

    Hirsutism is a common disorder in women of reproductive age, and androgen disturbances may aggravate the condition. Limited evidence exists regarding efficacy of hair removal in this specific population and no data are available for patients with verified normal testosterone levels.......Hirsutism is a common disorder in women of reproductive age, and androgen disturbances may aggravate the condition. Limited evidence exists regarding efficacy of hair removal in this specific population and no data are available for patients with verified normal testosterone levels....

  14. Mechanical muscle function and lean body mass during supervised strength training and testosterone therapy in aging men with low-normal testosterone levels

    DEFF Research Database (Denmark)

    Kvorning, Thue; Christensen, Louise L; Madsen, Klavs

    2013-01-01

    To examine the effect of strength training and testosterone therapy on mechanical muscle function and lean body mass (LBM) in aging men with low-normal testosterone levels in a randomized, double-blind, placebo-controlled 24-week study.......To examine the effect of strength training and testosterone therapy on mechanical muscle function and lean body mass (LBM) in aging men with low-normal testosterone levels in a randomized, double-blind, placebo-controlled 24-week study....

  15. Normal LDL-Cholesterol Levels Are Associated With Subclinical Atherosclerosis in the Absence of Risk Factors.

    Science.gov (United States)

    Fernández-Friera, Leticia; Fuster, Valentín; López-Melgar, Beatriz; Oliva, Belén; García-Ruiz, José M; Mendiguren, José; Bueno, Héctor; Pocock, Stuart; Ibáñez, Borja; Fernández-Ortiz, Antonio; Sanz, Javier

    2017-12-19

    Absence of cardiovascular risk factors (CVRFs) is traditionally considered low risk for atherosclerosis; however, individuals without CVRFs, as currently defined, still have events. This study sought to identify predictors of subclinical atherosclerosis in CVRF-free individuals. Participants from the PESA (Progression of Early Subclinical Atherosclerosis) study (n = 4,184) without conventional CVRFs were evaluated (n = 1,779; 45.0 ± 4.1 years, 50.3% women). CVRF freedom was defined as no current smoking and untreated blood pressure cholesterol cholesterol (LDL-C) cholesterol ≥40 mg/dl. A subgroup with optimal CVRFs (n = 740) was also defined as having blood pressure cholesterol LDL-C was independently associated with atherosclerosis presence and extent, in both the CVRF-free and CVRF-optimal groups (odds ratio [×10 mg/dl]: 1.14 to 1.18; p LDL-C, even at levels currently considered normal, is independently associated with the presence and extent of early systemic atherosclerosis in the absence of major CVRFs. These findings support more effective LDL-C lowering for primordial prevention, even in individuals conventionally considered at optimal risk. (Progression of Early Subclinical Atherosclerosis [PESA] Study; NCT01410318). Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Study of genetic variation at the level of DNA between normal and sterilized potato tuber moth males (phthorimaea operculella, zeller)

    International Nuclear Information System (INIS)

    Ammouneh, H.; Makee, H.; Idris, E.

    2009-06-01

    The main objective of current study was to determine the genetic variation at the level of DNA between the normal and sterilized potato tuber moth males. The required mating experiments were carried out to obtain partially sterilized males at 150 Gy and their offspring. Some biological factors of these males were estimated and compared to their unirradiated siblings. To acquire good quality and quantity of DNA for the AFLP technique, several methods were undertaken to isolate DNA of potato tuber moth male from different developmental stages especially from adult stage. However, a method called Modified M5 was used. By Modified M5, which required phenol for the isolation of DNA, in some samples 8 to 12 μg were obtained from one insect with 95-100% purity. In our study, AFLP technique was used to analyze the DNA samples of irradiated and unirradiated males from required mating. The result analysis showed that there was a clear genetic variability between examined individuals. However, the relationship between unirradiated F1 and F2 males was stronger than that between irradiated males. Thus, our result demonstrates that the AFLP could be efficiently utilized for studying genetic variation between insect species or between individuals of the same line which have biological differences induced by several factors such as irradiation. Moreover, this technique could enhance the effectiveness of sterile insect technique by using the AFLP in the monitoring system of released insects. (author)

  17. Study Of Genetic Variation At The Level Of DNA Between Normal And Steriled Potato Tuber Moth Males (Phthorimaea operculella, Zeller)

    International Nuclear Information System (INIS)

    Ammouneh, H.; Makee, H.; Idris, E.

    2010-01-01

    The main objective of current study was to determine the genetic variation at the level of DNA between the normal and sterilized potato tuber moth males. The required mating experiments were carried out to obtain partially sterilize males at 150 Gy and their offspring. Some biological factors of these males were estimated and compared to their unirradiated siblings. To acquire good quality and quantity of DNA for the AFLP technique, several methods were undertaken to isolate DNA of potato tuber moth male from different developmental stages especially from adult stage. However, a method called Modified M5 was used. By Modified M5, which required phenol for the isolation of DNA, in some samples 8 to 12 Mg were obtained from one insect with 95-100% purity. In our study, AFLP technique was used to analyze the DNA samples of irradiated and unirradiated males from required mating. The result analysis showed that there was a clear genetic variability between examined individuals. However, the relationship between unirradiated F1 and F2 males was stronger than that between irradiated males. Thus, our result demonstrates that the AFLP could be efficiently utilized for studying genetic variation between insect species or between individuals of the same line which have biological differences induced by several factors such as irradiation. Moreover, this technique could enhance the effectiveness of sterile insect technique by using the AFLP in the monitoring system of released insects. (author)

  18. Methodology development for radioactive waste treatment of CDTN/BR - liquid low-level radioactive wastes

    International Nuclear Information System (INIS)

    Morais, Carlos Antonio de

    1996-01-01

    The radioactive liquid wastes generated in Nuclear Technology Development Centre (CDTN) were initially treated by precipitation/filtration and then the resulting wet solid wastes were incorporated in cement. These wastes were composed of different chemicals and different radioactivities and were generated by different sectors. The objective of the waste treatment method was to obtain minimum wet solid waste volume and decontamination and minimum operational cost. The composition of the solid wastes were taken into consideration for compatible cementation process. Approximately 5,400 litres of liquid radioactive wastes were treated by this process during 1992-1995. The volume reduction was 1/24 th and contained 20% solids. (author)

  19. Research and development on low level liquid waste treatment in Thailand

    International Nuclear Information System (INIS)

    Yamkate, P.; Sinakhom, F.; Punnachaiya, M.; Chantaraprachoom, N.; Srisorn, S.

    1996-01-01

    The studies have been directed towards several subjects concerning the treatment technologies of low level waste. The simple physico-chemical method has been studied for applying to many kind of waste streams such as reactor waste, isotope production waste and liquid waste from the hospital. The characterization of inorganic ion-exchangers including the effect of pH, equilibrium time, temperature and concentration of such ion-exchangers were tested and the optimum condition of the sorption of C x on the exchangers are reported. The results from the investigation on the efficiencies of detergents in the radioactive decontamination reveal that the local simple brand machine-washed detergents. which is very cheap, can be best used as the decontaminating agent instead of the more expensive imported one. It is found that chemical precipitation methods i.e. phosphate coagulation, copper ferrocyanide coagulation and cobalt precipitation method can be used for treating of the waste stream arising successfully. In considering of the immobilizing process of treated waste, cementation is advised to be used and, therefore, subjects to be evaluated. The basic properties of cement-waste products as well the leachability of a particular types of sludge waste at 15-40% waste loading were investigated. The result reveals that, cement waste forms of inorganic ion-exchanger and of sludge waste from chemical precipitation of decontamination waste, exhibit high compressive strength and a low leach rates. The compressive strength of 118-207 Kg/cm 2 were found for the optimum waste products originated from various exchangers and 15-20% loading of sludge waste. The leachability of Co-60, Cs-134 and Sr-85 from 15-40% loading of cement waste for 30 days were studied. The cumulative fraction leached rate of Cs-134 from sludge-cement wastes was found to be about 17 x 10 - 3 g/cm 2 for 25 degree C and 50 degree C at 30 days leaching time respectively, while there were no leaching of Sr-85 and

  20. Determining the level of gross alpha and beta radioactivity of water from Marilao river using liquid scintillation counter

    International Nuclear Information System (INIS)

    Cruz, J.; Magtaka, J.; Balisi, R.; Castaneda, Soledad; De Vero, J.

    2009-01-01

    This study aims to determine the level of gross alpha- and beta- radioactivity present in the Marilao River. Liquid Scintillation Counter was used to detect samples radioactivity. Water samples were taken along the different spots of Marilao River. The results showed that the radioactivity are below the Philippine National Standard for Drinking Water (PNSDW) which is 0.1 Bq/L for gross alpha activity and 1.0 Bq/L for gross beta activity set by the Dept. of Health. Hence water samples from Marilao River, is safe in terms of the level of radioactivity levels.(author)

  1. Diagnostic value of blood lipids testing in patients with high-normal and subclinical levels of TSH in prevention and treatment of dislipoproteinemia

    Directory of Open Access Journals (Sweden)

    O D Rymar

    2010-12-01

    Full Text Available The purpose of the study is to evaluate character of lipid profile changes in Novosibirsk populational sample of men and women (45–69 years with subclinical and high-normal TSH levels. Current study was performed within the HAPIEE project “Determinants of cardiovascular diseases in Eastern Europe” of the Welcome Trust fond. Populational subsample of 280 subjects (125 men (44.6% and 155 women (55.4% was analyzed. Received data showed that high-normal TSH levels within 1.71–4.05 mIU/l have been associated with higher levels of triglycerides, total cholesterol and LDL cholesterol, compared with low-normal TSH levels 0.17–0.47 mIU/l (р<0.05. Women with subclinical hypothyroidism had significantly higher average levels of total cholesterol and LDL cholesterol compared with women without thyroid disorders.

  2. Serum Alanine Aminotransferase Levels within Normal Range Have Different Associations with Augmentation Index and Other Cardiometabolic Risk Factors in Nondrinkers and Drinkers: A Chinese Community-Based Analysis

    Directory of Open Access Journals (Sweden)

    Shihui Fu

    2017-01-01

    Full Text Available Background. To investigate whether serum alanine aminotransferase (ALT levels within normal range were associated with augmentation index (AIx and cardiometabolic risk factors in nondrinkers and drinkers in Chinese community-dwelling population. Methods. There were 4165 participants with serum ALT levels within normal range. Results. Alcohol drinking was observed in 1173 participants (28.2%. In multivariate analysis, serum ALT levels of nondrinkers were independently associated with age, sex, body mass index (BMI, hypertension, diabetes mellitus, diastolic blood pressure, triglyceride, low-density lipoprotein-cholesterol (LDL-c, and AIx, while serum ALT levels of drinkers were independently associated with age, sex, BMI, triglyceride, and LDL-c (p<0.05 for all. Conclusions. Associations of serum ALT levels within normal range with age, sex, body height and weight, and blood lipid were simultaneously present in participants with and without alcohol drinking, while associations of serum ALT levels within normal range with AIx, blood pressure, and glucose were seen in nondrinkers rather than in drinkers. These findings not only provide the evidence that serum ALT levels, even within the normal range, have different associations with arteriosclerosis and cardiometabolic risk factors in nondrinkers and drinkers but also are helpful in understanding the underlying pathophysiologic mechanisms linking the hepatic function to arteriosclerosis and cardiometabolic risk factors.

  3. Production of liquid biofuels in the world after 2000. Its level and dynamics

    Directory of Open Access Journals (Sweden)

    Michał Borychowski

    2014-08-01

    Full Text Available As crude oil resources decrease, the demand for this raw material is growing and its extraction is becoming less certain. In this situation the world turns to renewable energy sources, which include inter alia liquid biocomponents I generation (conventional biocomponents, which are produced from agricultural raw materials. The global biofuels has been sector is for several years developing fast. The main indications of this is the increasing production and consumption of liquid biocomponents in an increasing number of countries on all continents – both in developed countries, as well as developing countries. The main basis for the development of this industry tends to be the economic benefits, but we must not ignore the risks that arise in relation to this segment of the economy. The significance of this subject is fact that today the importance of liquid biocomponents (and other renewable energy sources is increasing. In addition, the production of biofuels from edible agricultural raw materials is controversial, and hence we need a world wide discourse to look at the sector from the perspective of both the benefits and risks (economic, social, environmental. The purpose of this article is to present the production and consumption of liquid biocomponents worldwide and in selected countries the release dynamics in recent years. In addition, this article is an attempt to identify the factors determining the development of the industry on a global scale.

  4. Management of radioactive low level liquid, gaseous, and solid wastes in the 200 areas

    International Nuclear Information System (INIS)

    White, A.T.

    1976-01-01

    The practices which are currently used for handling radioactive waste are outlined. These include burial of solid waste, scrubbing of off gas streams, and routing liquid effluents (mostly cooling water) to open ponds where the water percolates to the water table

  5. High resolution and high sensitivity methods for oligosaccharide mapping and characterization by normal phase high performance liquid chromatography following derivatization with highly fluorescent anthranilic acid.

    Science.gov (United States)

    Anumula, K R; Dhume, S T

    1998-07-01

    Facile labeling of oligosaccharides (acidic and neutral) in a nonselective manner was achieved with highly fluorescent anthranilic acid (AA, 2-aminobenzoic acid) (more than twice the intensity of 2-aminobenzamide, AB) for specific detection at very high sensitivity. Quantitative labeling in acetate-borate buffered methanol (approximately pH 5.0) at 80 degreesC for 60 min resulted in negligible or no desialylation of the oligosaccharides. A high resolution high performance liquid chromatographic method was developed for quantitative oligosaccharide mapping on a polymeric-NH2bonded (Astec) column operating under normal phase and anion exchange (NP-HPAEC) conditions. For isolation of oligosaccharides from the map by simple evaporation, the chromatographic conditions developed use volatile acetic acid-triethylamine buffer (approximately pH 4.0) systems. The mapping and characterization technology was developed using well characterized standard glycoproteins. The fluorescent oligosaccharide maps were similar to the maps obtained by the high pH anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD), except that the fluorescent maps contained more defined peaks. In the map, the oligosaccharides separated into groups based on charge, size, linkage, and overall structure in a manner similar to HPAEC-PAD with contribution of -COOH function from the label, anthranilic acid. However, selectivity of the column for sialic acid linkages was different. A second dimension normal phase HPLC (NP-HPLC) method was developed on an amide column (TSK Gel amide-80) for separation of the AA labeled neutral complex type and isomeric structures of high mannose type oligosaccharides. The oligosaccharides labeled with AA are compatible with biochemical and biophysical techniques, and use of matrix assisted laser desorption mass spectrometry for rapid determination of oligosaccharide mass map of glycoproteins is demonstrated. High resolution of NP-HPAEC and NP-HPLC methods

  6. Chemical evolution of leaked high-level liquid wastes in Hanford soils

    International Nuclear Information System (INIS)

    NYMAN, MAY D.; KRUMHANSL, JAMES L.; ZHANG, PENGCHU; ANDERSON, HOWARD L.; NENOFF, TINA M.

    2000-01-01

    A number of Hanford tanks have leaked high level radioactive wastes (HLW) into the surrounding unconsolidated sediments. The disequilibrium between atmospheric C0 2 or silica-rich soils and the highly caustic (pH > 13) fluids is a driving force for numerous reactions. Hazardous dissolved components such as 133 Cs, 79 Se, 99 Tc may be adsorbed or sequestered by alteration phases, or released in the vadose zone for further transport by surface water. Additionally, it is likely that precipitation and alteration reactions will change the soil permeability and consequently the fluid flow path in the sediments. In order to ascertain the location and mobility/immobility of the radionuclides from leaked solutions within the vadose zone, the authors are currently studying the chemical reactions between: (1) tank simulant solutions and Hanford soil fill minerals; and (2) tank simulant solutions and C0 2 . The authors are investigating soil-solution reactions at: (1) elevated temperatures (60--200 C) to simulate reactions which occur immediately adjacent a radiogenically heated tank; and (2) ambient temperature (25 C) to simulate reactions which take place further from the tanks. The authors studies show that reactions at elevated temperature result in dissolution of silicate minerals and precipitation of zeolitic phases. At 25 C, silicate dissolution is not significant except where smectite clays are involved. However, at this temperature CO 2 uptake by the solution results in precipitation of Al(OH) 3 (bayerite). In these studies, radionuclide analogues (Cs, Se and Re--for Tc) were partially removed from the test solutions both during high-temperature fluid-soil interactions and during room temperature bayerite precipitation. Altered soils would permanently retain a fraction of the Cs but essentially all of the Se and Re would be released once the plume was past and normal groundwater came in contact with the contaminated soil. Bayerite, however, will retain significant

  7. Chemical evolution of leaked high-level liquid wastes in Hanford soils

    Energy Technology Data Exchange (ETDEWEB)

    NYMAN,MAY D.; KRUMHANSL,JAMES L.; ZHANG,PENGCHU; ANDERSON,HOWARD L.; NENOFF,TINA M.

    2000-05-19

    A number of Hanford tanks have leaked high level radioactive wastes (HLW) into the surrounding unconsolidated sediments. The disequilibrium between atmospheric C0{sub 2} or silica-rich soils and the highly caustic (pH > 13) fluids is a driving force for numerous reactions. Hazardous dissolved components such as {sup 133}Cs, {sup 79}Se, {sup 99}Tc may be adsorbed or sequestered by alteration phases, or released in the vadose zone for further transport by surface water. Additionally, it is likely that precipitation and alteration reactions will change the soil permeability and consequently the fluid flow path in the sediments. In order to ascertain the location and mobility/immobility of the radionuclides from leaked solutions within the vadose zone, the authors are currently studying the chemical reactions between: (1) tank simulant solutions and Hanford soil fill minerals; and (2) tank simulant solutions and C0{sub 2}. The authors are investigating soil-solution reactions at: (1) elevated temperatures (60--200 C) to simulate reactions which occur immediately adjacent a radiogenically heated tank; and (2) ambient temperature (25 C) to simulate reactions which take place further from the tanks. The authors studies show that reactions at elevated temperature result in dissolution of silicate minerals and precipitation of zeolitic phases. At 25 C, silicate dissolution is not significant except where smectite clays are involved. However, at this temperature CO{sub 2} uptake by the solution results in precipitation of Al(OH){sub 3} (bayerite). In these studies, radionuclide analogues (Cs, Se and Re--for Tc) were partially removed from the test solutions both during high-temperature fluid-soil interactions and during room temperature bayerite precipitation. Altered soils would permanently retain a fraction of the Cs but essentially all of the Se and Re would be released once the plume was past and normal groundwater came in contact with the contaminated soil. Bayerite

  8. Laboratory studies on leaching of low grade uranium ores and treatment of low level liquid waste generated by leaching experiments

    International Nuclear Information System (INIS)

    Palabrica, O.T.; Antonino, E.J.; Caluag, L.A.; Villamater, D.

    1980-07-01

    Acid leaching experiments of preconcentrated uranium ore were carried out at a pulp density of 50% solids, using sulfuric acid with sodium chlorate as oxidant. The different leaching parameters considered in this work were temperature, oxidant level and leaching time. In the experimental procedure, the concentration of oxidant and the temperature were varied to determine how they affect the leaching process. Experimental results are illustrated in tabulated form for better interpretation. Uranium analyses were done by fluorimetric and delayed-neutron activation analysis. An anion exchange method using Dowex 1 x 8, 200-400 mesh (Cl - ) was used in treating the low-level liquid waste generated by leaching experiments. The purpose of this treatment was to minimize radioactive contamination in the waste materials and also to recover some of the uranium left in the liquid waste. (author)

  9. Normal-phase liquid chromatography retention behavior of polycyclic aromatic hydrocarbon and their methyl-substituted derivatives on an aminopropyl stationary phase.

    Science.gov (United States)

    Wilson, Walter B; Hayes, Hugh V; Sander, Lane C; Campiglia, Andres D; Wise, Stephen A

    2017-09-01

    Retention indices for 124 polycyclic aromatic hydrocarbons (PAHs) and 62 methyl-substituted (Me-) PAHs were determined using normal-phase liquid chromatography (NPLC) on a aminopropyl (NH 2 ) stationary phase. PAH retention behavior on the NH 2 phase is correlated to the total number of aromatic carbons in the PAH structure. Within an isomer group, non-planar isomers generally elute earlier than planar isomers. MePAHs generally elute slightly later but in the same region as the parent PAHs. Correlations between PAH retention behavior on the NH 2 phase and PAH thickness (T) values were investigated to determine the influence of non-planarity for isomeric PAHs with four to seven aromatic rings. Correlation coefficients ranged from r = 0.19 (five-ring peri-condensed molecular mass (MM) 252 Da) to r = -0.99 (five-ring cata-condensed MM 278 Da). In the case of the smaller PAHs (MM ≤ 252 Da), most of the PAHs had a planar structure and provided a low correlation. In the case of larger PAHs (MM ≥ 278 Da), nonplanarity had a significant influence on the retention behavior and good correlation between retention and T was obtained for the MM 278 Da, MM 302 Da, MM 328 Da, and MM 378 Da isomer sets. Graphical abstract NPLC separation of the three-, four-, five-, and six-ring PAH isomers with different number of aromatic carbon atoms and degrees of non-planarity (Thickness, T). The inserted figure plots the number of aromatic carbon atoms vs. the log I value for the 124 parent PAHs.

  10. Numerical simulation of interface movement in gas-liquid two-phase flows with Level Set method

    International Nuclear Information System (INIS)

    Li Huixiong; Chinese Academy of Sciences, Beijing; Deng Sheng; Chen Tingkuan; Zhao Jianfu; Wang Fei

    2005-01-01

    Numerical simulation of gas-liquid two-phase flow and heat transfer has been an attractive work for a quite long time, but still remains as a knotty difficulty due to the inherent complexities of the gas-liquid two-phase flow resulted from the existence of moving interfaces with topology changes. This paper reports the effort and the latest advances that have been made by the authors, with special emphasis on the methods for computing solutions to the advection equation of the Level set function, which is utilized to capture the moving interfaces in gas-liquid two-phase flows. Three different schemes, i.e. the simple finite difference scheme, the Superbee-TVD scheme and the 5-order WENO scheme in combination with the Runge-Kutta method are respectively applied to solve the advection equation of the Level Set. A numerical procedure based on the well-verified SIMPLER method is employed to numerically calculate the momentum equations of the two-phase flow. The above-mentioned three schemes are employed to simulate the movement of four typical interfaces under 5 typical flowing conditions. Analysis of the numerical results shows that the 5-order WENO scheme and the Superbee-TVD scheme are much better than the simple finite difference scheme, and the 5-order WENO scheme is the best to compute solutions to the advection equation of the Level Set. The 5-order WENO scheme will be employed as the main scheme to get solutions to the advection equations of the Level Set when gas-liquid two-phase flows are numerically studied in the future. (authors)

  11. ASRDI oxygen technology survey. Volume 5: Density and liquid level measurement instrumentation for the cryogenic fluids oxygen, hydrogen, and nitrogen

    Science.gov (United States)

    Roder, H. M.

    1974-01-01

    Information is presented on instrumentation for density measurement, liquid level measurement, quantity gauging, and phase measurement. Coverage of existing information directly concerned with oxygen was given primary emphasis. A description of the physical principle of measurement for each instrumentation type is included. The basic materials of construction are listed if available from the source document for each instrument discussed. Cleaning requirements, procedures, and verification techniques are included.

  12. A Facile Vortex-Assisted Dispersive Liquid-Liquid Microextraction Method for the Determination of Uranyl Ion at Low Levels by Spectrophotometry.

    Science.gov (United States)

    Corazza, Marcela Zanetti; Pires, Igor Matheus Ruiz; Diniz, Kristiany Moreira; Segatelli, Mariana Gava; Tarley, César Ricardo Teixeira

    2015-08-01

    A facile and reliable UV-Vis spectrophotometric method associated with vortex-assisted dispersive liquid-liquid microextraction has been developed and applied to the determination of U(VI) at low levels in water samples. It was based on preconcentration of 24.0 mL sample at pH 8.0 in the presence of 7.4 µmol L(-1) 1-(2-pyridylazo)-2-naphthol, 1.0 mL of methanol as disperser solvent and 1.0 mL of chloroform as extraction solvent. A high preconcentration factor was achieved (396 times), thus providing a wide analytical curve from 6.9 up to 75.9 µg L(-1) (r=0.9982) and limits of detection and quantification of 0.40 and 1.30 µg L(-1), respectively. When necessary, EDTA or KCN can be used to remove interferences of foreign ions. The method was applied to the analysis of real water samples, such as tap, mineral and lake waters with good recovery values.

  13. Caesium extraction from acidic high level liquid wastes with functionalized calixarenes

    International Nuclear Information System (INIS)

    Simon, N.; Eymard, S.; Tournois, B.; Dozol, J.F.

    2000-01-01

    In the framework of French law programme, studies are under way to selectively remove caesium from acidic high activity wastes. Calix[4]arene crown derivatives exhibit outstanding efficiency and selectivity for caesium. An optimisation of the formulation of a selective extractant system for Cs based on crown calixarenes and usable in a process which use liquid-liquid extraction is presented. A system involving a monoamide as a modifier is proposed. Besides these improvements, a reference solvent based on a standard 1,3-di-(n-octyl-oxy)2,4-calix(4)arene crown is studied. Flow-sheets related to this system are calculated and easily transferable to the optimised new system. (authors)

  14. Sensory characteristics of liquids thickened with commercial thickeners to levels specified in the International Dysphagia Diet Standardization Initiative (IDDSI) framework.

    Science.gov (United States)

    Ong, Jane Jun-Xin; Steele, Catriona M; Duizer, Lisa M

    2018-06-01

    Sensory characteristics are important for the acceptance of thickened liquids, but those of liquids thickened to the new standards put forth by the International Dysphagia Diet Standardization Initiative (IDDSI) are unknown. This research sought to identify and rate the perception of important sensory properties of liquids thickened to levels specified in the IDDSI framework. Samples were made with water, with and without added barium sulfate, and were thickened with a cornstarch or xanthan gum based thickener. Samples were characterized using projective mapping/ultra-flash profiling to identify important sample attributes, and then with trained descriptive analysis panels to characterize those attributes in non-barium and barium thickened liquids. Three main groups of attributes were observed. Taste and flavor attributes decreased in intensity with increasing thickener. Thickener specific attributes included graininess and chalkiness for the cornstarch thickened samples, and slipperiness for the xanthan gum samples. Within the same type of thickener, ratings of thickness-related attributes (perceived viscosity, adhesiveness, manipulation, and swallowing) at different IDDSI levels were significantly different from each other. However, in non-barium samples, cornstarch samples were perceived as thicker than xanthan gum samples even though they had similar apparent viscosities at 50 s -1 . On the other hand, the two thickeners had similar perceived thickness in the barium samples even though the apparent viscosities of cornstarch samples were higher than those of the xanthan gum samples. In conclusion, IDDSI levels can be distinguished based on sensory properties, but these properties may be affected by the type of thickener and medium being thickened.

  15. Health physics challenges during decontamination for safe disposal of low level liquid effluent tank as inactive scrap

    International Nuclear Information System (INIS)

    Akila, R.; Sultan, Bajeer; Sarangapani, R.; Jose, M.T.

    2018-01-01

    The Low-level Liquid waste (LLW) generated during the regeneration of mixed bed column of KAMINI reactor is collected in the SS Delay Tanks located on the western side of RML building. It was proposed to dismantle and dispose the tank as solid waste. The tank weighs about 2 ton. An attempt was made to decontaminate the tank to levels below the exempt quantity so as to qualify it as scrap of unrestricted release. This is first time in IGCAR wherein a material used in a radioactive facility for storing LLW is being released as scrap of unrestricted release and this paper discusses about the same

  16. Low-level detection and quantification of Plutonium(III, IV, V,and VI) using a liquid core waveguide

    International Nuclear Information System (INIS)

    Wilson, Richard E.; Hu, Yung-Jin; Nitsche, Heino

    2003-01-01

    Understanding the aqueous chemistry of plutonium, in particular in environmental conditions, is often complicated by plutonium's complex redox chemistry. Because plutonium possesses four oxidation states, all of which can coexist in solution, a reliable method for the identification of these oxidation states is needed. The identification of plutonium oxidation states at low levels in aqueous solution is often accomplished through an indirect determination using series of liquid-liquid extraction procedures using oxidation state specific reagents such as HDEHP and TTA. While these methods, coupled with radioactive counting techniques provide superior limits of detection they may influence the plutonium redox equilibrium, are time consuming, waste intensive and costly. Other analytical methods such as mass spectrometry and radioactive counting as stand alone methods provide excellent detection limits but lack the ability to discriminate between the oxidation states of the plutonium ions in solution

  17. [Blood levels of homocysteine by high pressure liquid chromatography and comparison with two other techniques].

    Science.gov (United States)

    Ceppa, F; Drouillard, I; Chianea, D; Burnat, P; Perrier, F; Vaillant, C; El Jahiri, Y

    1999-01-01

    Cardio-vascular diseases are the most common cause of death in industrialized countries. A new marker has emerged among offending risk factors in the past few years: homocysteine. This sulphured amino-acid is an important intermediate in transsulphuration and remethylation reactions of methionine's metabolism. We proposed to evaluate a home made method of determination for this parameter by high performance liquid chromatography (HPLC) and to compare it to fluorescence polarization immunoassay technique (FPIA) and to gaz phase chromatography (CG-SM). This method associated with good sensibility and precision remain much less expensive than FPIA technique.

  18. Separation of cesium from intermediate level liquid radioactive waste by solvent extraction with antioxidants

    International Nuclear Information System (INIS)

    Gulis, G.

    1989-01-01

    Antioxidants AO 2246, AO 4, AO 4K, AO 301 (Czechoslovakia) and NOCRAC 2246 (Japan) were tested as extracting agents for the separation of cesiium by solvent extraction with substituted phenols. The following effects on extraction were studied: pH of water phase, influence of diluent and of antioxidant concentration, extraction time, influence of salt content. The extraction of cesium from liquid radioactive waste was tested. The best results were obtained by NOCRAC 2246 in nitrobenzene, the extraction efficiency was 92.3% with pH 13.23. (author) 7 refs.; 5 figs.; 4 tabs

  19. Summary report on partitioning cesium from the Chinese high level liquid waste(HLLW) by calixcrown

    International Nuclear Information System (INIS)

    Wang Jianchen; Chen Jing

    2011-01-01

    The partitioning of Cesium from the HLLW with a higher-salts liquid from PUREX is a better choice for its further treatment or disposal. In this work, the progress of partitioning Cesium from the Chinese HLLW by 25,27-bis(2-propyloxy) calix[4]-26,28-crown-6(iPr-C[4]C-6) were introduced, including the synthesis method of calixcrown, selection of diluents, extraction properties, the radiolytic stability, cold test and hot test of cascade extraction for removing cesium from HLLW. (author)

  20. Distribution characteristics of stock market liquidity

    Science.gov (United States)

    Luo, Jiawen; Chen, Langnan; Liu, Hao

    2013-12-01

    We examine the distribution characteristics of stock market liquidity by employing the generalized additive models for location, scale and shape (GAMLSS) model and three-minute frequency data from Chinese stock markets. We find that the BCPE distribution within the GAMLSS framework fits the distributions of stock market liquidity well with the diagnosis test. We also find that the stock market index exhibits a significant impact on the distributions of stock market liquidity. The stock market liquidity usually exhibits a positive skewness, but a normal distribution at a low level of stock market index and a high-peak and fat-tail shape at a high level of stock market index.

  1. Development of a radioimmunoassay for pregnancy-associated plasma protein A and establishment of normal levels in the first trimester of pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Anthony, F; Masson, G M; Wood, P J [Southampton Univ. (UK)

    1983-01-01

    An accelerated double antibody method has been developed for the radioimmunoassay of pregnancy-associated plasma protein A (PAPP-A) in serum. The workable range for the assay was 0.4-1.8 mg/l of serum. PAPP-A levels were determined in single serum samples from 110 women with prospective normal pregnancies of between 7 and 14 weeks' gestation. The level of pregnancy specific ..beta../sub 1/ glycoprotein (SP/sub 1/) was also measured in these samples and normal ranges for PAPP-P and SP/sub 1/ were constructed from the results obtained.

  2. Development of a radioimmunoassay for pregnancy-associated plasma protein A and establishment of normal levels in the first trimester of pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Anthony, F; Masson, G M; Wood, P J [Southampton Univ. (UK)

    1983-01-01

    An accelerated double antibody method has been developed for the radioimmunoassay of pregnancy-associated plasma protein A (PAPP-A) in serum. The workable range for the assay was 0.04-1.8 mg/l of serum. PAPP-A levels were determined in single serum samples from 110 women with prospective normal pregnancies of between 7 and 14 weeks' gestation. The level of pregnancy specific ..beta../sub 1/ glycoprotein (SP/sub 1/) was also measured in these samples and normal ranges for PAPP-A and SP/sub 1/ were constructed from the results obtained.

  3. Development of a radioimmunoassay for pregnancy-associated plasma protein A and establishment of normal levels in the first trimester of pregnancy

    International Nuclear Information System (INIS)

    Anthony, F.; Masson, G.M.; Wood, P.J.

    1983-01-01

    An accelerated double antibody method has been developed for the radioimmunoassay of pregnancy-associated plasma protein A (PAPP-A) in serum. The workable range for the assay was 0.4-1.8 mg/l of serum. PAPP-A levels were determined in single serum samples from 110 women with prospective normal pregnancies of between 7 and 14 weeks' gestation. The level of pregnancy specific #betta# 1 glycoprotein (SP 1 ) was also measured in these samples and normal ranges for PAPP-P and SP 1 were constructed from the results obtained. (author)

  4. Measurement of gas-liquid two-phase flow around horizontal tube bundle using SF6-water. Simulating high-pressure high-temperature gas-liquid two-phase flow of PWR/SG secondary coolant side at normal pressure

    International Nuclear Information System (INIS)

    Ishikawa, Atsushi; Imai, Ryoj; Tanaka, Takahiro

    2014-01-01

    In order to improve prediction accuracy of analysis code used for design and development of industrial products, technology had been developed to create and evaluate constitutive equation incorporated in analysis code. The experimental facility for PWR/SG U tubes part was manufactured to measure local void fraction and gas-liquid interfacial velocity with forming gas-liquid upward two-phase flow simulating high-pressure high-temperature secondary coolant (water-steam) rising vertically around horizontal tube bundle. The experimental facility could reproduce flow field having gas-liquid density ratio equivalent to real system with no heating using SF6 (Sulfur Hexafluoride) gas at normal temperature and pressure less than 1 MPa, because gas-liquid density ratio, surface tension and gas-liquid viscosity ratio were important parameters to determine state of gas-liquid two-phase flow and gas-liquid density ratio was most influential. Void fraction was measured by two different methods of bi-optical probe and conductivity type probe. Test results of gas-liquid interfacial velocity vs. apparent velocity were in good agreement with existing empirical equation within 10% error, which could confirm integrity of experimental facility and appropriateness of measuring method so as to set up original constitutive equation in the future. (T. Tanaka)

  5. Two-phase mixture level swell and liquid entrainment/off-take in a vessel during rapid depressurization

    International Nuclear Information System (INIS)

    Kim, Chang Hyun

    2004-02-01

    An experimental study has been performed to analyze the two-phase mixture level swell and the liquid entrainment/off-take through the break in a vessel, which are important phenomena to determine the bleed capacity of the Safety Depressurization System (SDS) of Korea Advanced Power Reactor 1400 (APR1400). Three separate experiments are performed in this study: (a) the depressurization and two-phase mixture level swell experiment: (b) the two-phase mixture level measurement experiment: (c) the liquid entrainment and off-take experiment. A series of experiments has been performed using a scaled pressurized vessel in various depressurization conditions to analyze the two-phase mixture level swell and the liquid entrainment/off-take phenomena from the two-phase mixture surface in the first experiment. The test parameters are the initial pressure (10 - 38.75bars), the initial water level (43.7% - 80.0% of full height), the orifice inner diameter (10mm, 17.5mm, and 20mm). The liquid off-take takes place in certain experimental conditions. The measured parameters in the present experiments are axial void fraction distributions, pressures, temperatures in the test vessel, and the mixture density and mass flowrate through the discharge pipe. An assessment of RELAP5/MOD3 code with the present experimental data has been performed. With appropriate nodalization and time step, RELAP5/MOD3 showed reasonable agreement with the present experimental data for the gradual depressurization without liquid off-take. In the case that the off-take takes place, however, RELAP5/MOD3 under-predicts the amount of liquid entrainment/off-take during depressurization. In the second experiment, an assessment of an ultrasonic sensor and a two-wire type capacitance probe for the two-phase mixture level measurement has been performed under the same experimental conditions to adopt an appropriate measurement method for the two-phase mixture level swell and to investigate pool void fraction by the

  6. A measurement of the absorption of liquid argon scintillation light by dissolved nitrogen at the part-per-million level

    International Nuclear Information System (INIS)

    Jones, B J P; Chiu, C S; Conrad, J M; Ignarra, C M; Katori, T; Toups, M

    2013-01-01

    We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon and monitor the light yield from an alpha source. The source is placed at different distances from a cryogenic photomultiplier tube assembly. By comparing the light yield from each position we extract the absorption cross section of nitrogen. We find that nitrogen absorbs argon scintillation light with strength of (1.51±0.15) × 10 −4 cm −1 ppm −1 , corresponding to an absorption cross section of (4.99±0.51) × 10 −21 cm 2 molecule −1 . We obtain the relationship between absorption length and nitrogen concentration over the 0 to 50 ppm range and discuss the implications for the design and data analysis of future large liquid argon time projection chamber (LArTPC) detectors. Our results indicate that for a current-generation LArTPC, where a concentration of 2 parts per million of nitrogen is expected, the attenuation length due to nitrogen will be 30±3 meters

  7. The selective removal of 90Sr and 137Cs from liquid low-level waste at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Bostick, D.T.; Arnold, W.D.; Burgess, M.W.; Taylor, P.A.; Kent, T.E.

    1995-01-01

    Methods are being developed for the selective removal of the two principal radioactive contaminants, 90 Sr and 137 Cs, from liquid low-level waste generated and/or stored at Oak Ridge National Laboratory. These methods are to be used in a future centralized treatment facility at ORNL. Removal of 90 Sr in the proposed treatment flashed is based on coprecipitation from strongly alkaline waste by adding stable strontium to the waste solution. Ferric sulfate, added with the stable strontium, improves the 90 Sr removal and aids in the flocculation of the strontium carbonate (SrCO 3 ) precipitate. After separation of the solids, the resultant supernate is adjusted to pH 8 for the cesium removal treatment. Upon pH adjustment, aluminum originally present in the untreated alkaline waste precipitates and sorbs an additional amount of 90 Sr. Cesium is removed from the neutralized waste by two sequential treatments with potassium cobalt hexacyanoferrate (KCCF) slurry formed by the addition of potassium ferrocyanide (K 4 Fe(CN) 6 ) and cobalt nitrate (Co(NO 3 ) 2 ) solutions. The cumulative decontamination factors (DFs) for 90 Sr and 137 Cs in benchscale studies are 4900 and 1 x 10 6 , respectively, if high speed centrifugation is used for the liquid/solid separations. Efforts are now underway to evaluate process-scale techniques to perform the liquid/solid separations required for removal of SrCO 3 and 137 Cs-bearing hexacyanoferrate solids from the treated waste solution

  8. Maternal serum lipid levels in pregnant women with gestational diabetes mellitus (GDM in comparison to normal pregnant women

    Directory of Open Access Journals (Sweden)

    soheila Akbari

    2013-02-01

    Conclusion: Due to positive correlation of hypertriglyceridemia and hyperinsulinemia, it is possible to assume that elevated TGs levels in GDM cases is a reflection of variation in maternal insulin levels.

  9. Studies on level of cytokines and expression of connexin43 in tumor and normal cells in culture conditions

    International Nuclear Information System (INIS)

    Asati, V.; Pandey, B.N.

    2016-01-01

    Factors secreted from the tumor cells in culture medium have been known to facilitate the growth of fresh cultures and also to affect the cellular radio-sensitivity. Moreover, expression of gap junction proteins like connexin-43 is known as a key player in cell survival and proliferation. The present study is aimed to evaluate the effects of conditioned medium on the growth of respective tumor/normal cells and the expression of connexin-43 in these cells

  10. Initiation of glucose-lowering treatment decreases international normalized ratio levels among users of vitamin K antagonists

    DEFF Research Database (Denmark)

    Stage, Tore Bjerregaard; Pottegård, Anton; Henriksen, Daniel Pilsgaard

    2016-01-01

    -lowering treatment affects international normalized ratio (INR) and dose requirements of the anticoagulant VKAs warfarin and phenprocoumon. PATIENTS/METHODS: We performed a self-controlled retrospective register-based study. A total of 118 patients initiating glucose-lowering treatment while being treated......-lowering treatment reduces the anticoagulant effect of VKA to an extent that is likely to be clinically relevant. This finding needs confirmation and mechanistic explanation. This article is protected by copyright. All rights reserved....

  11. A high recovery membrane process for purification of low-level radioactive liquid waste

    Energy Technology Data Exchange (ETDEWEB)

    Al-Samadi, R. [Ontario Power Generation, Pickering, Ontario (Canada); Davloor, R.; Harper, B., E-mail: ram.davloor@brucepower.com [Bruce Power, Tiverton, Ontario (Canada)

    2013-07-01

    An advanced Active Liquid Waste Treatment System (ALWTS) was designed placed in-service at the Bruce Nuclear Generating Station 'A' in 1999. As part of this unique system an innovative high recovery reverse osmosis system (ROS) was installed to concentrate the contaminants into a small retentate stream that can be processed on-site or sent off-site for disposal. The permeate is discharged to the lake. The overall permeate recovery of the system is greater than 98%. This patented system which saw its first commercial application at the station has now operated continuously for over thirteen years. It has enabled the ALWTS to consistently produce high quality effluent that exceeds environmental discharge limits. This paper discusses the high recovery membrane process its unique design features aimed at minimizing the volume of rejects its separation performance operating history. (author)

  12. A high recovery membrane process for purification of low-level radioactive liquid waste

    International Nuclear Information System (INIS)

    Al-Samadi, R.; Davloor, R.; Harper, B.

    2013-01-01

    An advanced Active Liquid Waste Treatment System (ALWTS) was designed placed in-service at the Bruce Nuclear Generating Station 'A' in 1999. As part of this unique system an innovative high recovery reverse osmosis system (ROS) was installed to concentrate the contaminants into a small retentate stream that can be processed on-site or sent off-site for disposal. The permeate is discharged to the lake. The overall permeate recovery of the system is greater than 98%. This patented system which saw its first commercial application at the station has now operated continuously for over thirteen years. It has enabled the ALWTS to consistently produce high quality effluent that exceeds environmental discharge limits. This paper discusses the high recovery membrane process its unique design features aimed at minimizing the volume of rejects its separation performance operating history. (author)

  13. Volume reduction and solidification of liquid and solid low-level radioactive waste

    International Nuclear Information System (INIS)

    May, J.R.

    1979-01-01

    This paper presents a brief background of the development of a method of radioactive waste volume reduction using a unique fluidized bed calciner/incinerator. The volume reduction system is capable of processing a variety of liquid chemical wastes, spent ion exchange resin beads, filter treatment sludges, contaminated lubricating oils, and miscellaneous combustible solids such as paper, rags, protective clothing, wood, etc. All of these wastes are processed in one chemical reaction vessel. Detailed process data is presented that shows the system is capable of reducing the total volume of disposable radioactive waste generated by light water reactors by a factor of 10. Equally important to reducing the volume of power reactor radwaste is the final form of the stored or disposable radwaste. This paper also presents process data related to a new radwaste solidification system, presently being developed, that is particularly suited for immobilizing the granular solids and ashes resulting from volume reduction by calcination and/or incineration

  14. Vitamin D levels in patients with albinism compared with those in normally pigmented Black patients attending dermatology clinics in the Free State province, South Africa.

    Science.gov (United States)

    Van der Walt, Johanna E C; Sinclair, Werner

    2016-09-01

    Associations between vitamin D deficiency and a broad variety of independent diseases, including several bone diseases, various types of cancer, autoimmune diseases, hypertension, and cardiovascular disease, have been suggested. It is therefore important to detect and treat vitamin D deficiency in high-risk groups. Because patients with albinism (PWA) practice a policy of strict sun avoidance, they may be at risk for low levels of vitamin D. This study was conducted in patients attending dermatology clinics in the Free State, South Africa, to determine sun avoidance behavior in the patient population and to compare 25-hydroxyvitamin D (25[OH]D) levels in PWA with those in normally pigmented Black patients attending the same clinics. Serum 25(OH)D levels were assessed in 50 PWA and 50 normally pigmented Black control subjects. Questionnaires on sun exposure avoidance behaviors were administered to all participants. The present study showed no statistically significant difference in median 25(OH)D levels between PWA and controls with normally pigmented Black skin. Rather, the study found a tendency for controls to have lower 25(OH)D levels. A total of 53% (n = 53) of all study participants (PWA and controls) had a 25(OH)D level of albinism attending dermatology clinics in the Free State, South Africa, need not be viewed as specifically at risk for low vitamin D levels. © 2015 The International Society of Dermatology.

  15. Fasting plasma glucose and serum uric acid levels in a general Chinese population with normal glucose tolerance: A U-shaped curve.

    Directory of Open Access Journals (Sweden)

    Yunyang Wang

    Full Text Available Although several epidemiological studies assessed the relationship between fasting plasma glucose (FPG and serum uric acid (SUA levels, the results were inconsistent. A cross-sectional study was conducted to investigate this relationship in Chinese individuals with normal glucose tolerance.A total of 5,726 women and 5,457 men with normal glucose tolerance were enrolled in the study. All subjects underwent a 75-g oral glucose tolerance test. Generalized additive models and two-piecewise linear regression models were applied to assess the relationship.A U-shaped relationship between FPG and SUA was observed. After adjusting for potential confounders, the inflection points of FPG levels in the curves were 4.6 mmol/L in women and 4.7 mmol/L in men respectively. SUA levels decreased with increasing fasting plasma glucose concentrations before the inflection points (regression coefficient [β] = -36.4, P < 0.001 for women; β = -33.5, P < 0.001 for men, then SUA levels increased (β = 17.8, P < 0.001 for women; β = 13.9, P < 0.001 for men. Additionally, serum insulin levels were positively associated with FPG and SUA (P < 0.05.A U-shaped relationship between FPG and SUA levels existed in Chinese individuals with normal glucose tolerance. The association is partly mediated through serum insulin levels.

  16. Design and Real Time Implementation of CDM-PI Control System in a Conical Tank Liquid Level Process

    Directory of Open Access Journals (Sweden)

    P. K. Bhaba

    2011-10-01

    Full Text Available The work focuses on the design and real time implementation of Coefficient Diagram Method (CDM based PI (CDM-PI control system for a Conical Tank Liquid Level Process (CTLLP which exhibits severe static non-linear characteristics. By taking this static non-linearity into account, a Wiener Model (WM based CDM-PI control system is developed and implemented in real time operations. The performance of this control system for set point tracking and load disturbance rejection is studied. In addition, the performance is compared with other WM based PI controllers. Real time results clearly show that WM based CDM-PI control system outperforms over the others.

  17. On levels unconditional declassification of solid materials with very low radioactive content and downloads liquids and gases to the environment

    International Nuclear Information System (INIS)

    2004-01-01

    This guide aims to establish radiological criteria for declassification (waiver) of the radioactive material of radiological regulatory control and levels unconditional clearance for solid materials and the authorized discharge limits for liquids and gases to the environment that meet these criteria for exposure scenarios acceptably conservative. This Guide to radioactive waste from the apply industrial, medical and research, which they will be managed as waste conventional. This guidance excludes from its scope the option of recycling and reuse of materials that have been declassified and wastes arising from activities and practices which naturally occurring radionuclides present are.

  18. Nondestructive testing of the low-level radioactive waste drums for uni-axial compressive strength and free liquid content

    International Nuclear Information System (INIS)

    Yu Geping; Chang Mingyu; Wang Yeajeng; Chu, David S.L.; Ju Yihzen

    1992-01-01

    This paper summarizes the nondestructive test to determine the uni-axial compressive strength and free water content of solidified low level radioactive waste. The uni-axial compressive strength is determined by ultrasonic wave propagation speed, and the results are compared with those of compressive tests. Three methods of detecting the surface free water by ultrasonic testing are established, the ultrasonic wave speed, wave form and pulse height are used to determine the existence and amount of the surface free liquid. Possible difficulties are discussed. (author)

  19. Determination of free acid in high level liquid wastes by means of fixed pH value

    International Nuclear Information System (INIS)

    Li Jifu; Duan Shirong; Wu Xi; Yu Xueren

    1991-01-01

    For the determination of free acid in high level liquid wastes, 8% potassium oxalate solution with pH 6.50 as a complex agent of hydrolizable ion is added to 1 AW and the solution is titrated with standard sodium hydroxide to reach the original pH value. The quantity of free acid is calculated by standard sodium hydroxide consumed. This method is simple, rapid and accurate. The relative error of analysis is less than ±4%. The average percentage of recovery is 99.6-101.0%

  20. Electron mobility on the surface of liquid Helium: influence of surface level atoms and depopulation of lowest subbands

    International Nuclear Information System (INIS)

    Grigoriev, P. D.; Dyugaev, A. M.; Lebedeva, E. V.

    2008-01-01

    The temperature dependence of electron mobility is examined. We calculate the contribution to the electron scattering rate from the surface level atoms (SLAs), proposed in [10]. This contribution is substantial at low temperatures T < 0.5, when the He vapor concentration is exponentially small. We also study the effect of depopulation of the lowest energy subband, which leads to an increase in the electron mobility at high temperature. The results explain certain long-standing discrepancies between the existing theory and experiment on electron mobility on the surface of liquid helium