WorldWideScience

Sample records for normal coagulation profile

  1. Coagulation profiles of healthy Andalusian donkeys are different than those of healthy horses.

    Science.gov (United States)

    Mendoza, F J; Perez-Ecija, R A; Monreal, L; Estepa, J C

    2011-01-01

    Coagulation disorders are frequently diagnosed, especially in hospitalized equidae, and result in increased morbidity and mortality. However, hemostatic reference intervals have not been established for donkeys yet. To determine whether the most common coagulation parameters used in equine practice are different between healthy donkeys and horses. Thirty-eight healthy donkeys and 29 healthy horses. Blood samples were collected to assess both coagulation and fibrinolytic systems by determination of platelet count, fibrinogen concentration, clotting times (prothrombin time [PT] and activated partial thromboplastin time [aPTT]), fibrin degradation products (FDP) and D-Dimer concentrations. PT and aPTT in donkeys were significantly (P donkeys than in horses. The coagulation parameters most commonly determined in equine practice are different in donkeys compared with horses. Thus, the use of normal reference ranges reported previously for healthy horses in donkeys might lead to a misdiagnosis of coagulopathy in healthy donkeys, and unnecessary treatments in sick donkeys. This is the first report of normal coagulation profile results in donkeys, and further studies are warranted to elucidate the physiological mechanisms of the differences observed between donkeys and horses. Copyright © 2011 by the American College of Veterinary Internal Medicine.

  2. Coagulation Profile as a Risk Factor for 30-day Morbidity Following Cervical Laminectomy and Fusion.

    Science.gov (United States)

    Bronheim, Rachel S; Oermann, Eric K; Cho, Samuel K; Caridi, John M

    2018-02-15

    Retrospective analysis of prospectively collected data. The aim of this study was to determine the ability of abnormal coagulation profile to predict adverse events following posterior cervical laminectomy and fusion (PCLF). PCLF is an increasingly common procedure used to treat a variety of traumatic and degenerative spinal conditions. Abnormal coagulation profile is associated with postoperative adverse events, including blood transfusion. There is a paucity of literature that specifically addresses the relationship between coagulation profile and complications following PCLF. ACS-NSQIP was utilized to identify patients undergoing PCLF between 2006 and 2013. A total of 3546 patients met inclusion criteria. Multivariate analysis was utilized to identify associations between abnormal coagulation profile and postoperative complications. Membership in the low-platelet cohort was an independent risk factor for myocardial infarction (Odds Ratio (OR) = 5.4 [1.0, 29.1], P = 0.049) and bleeding transfusion (OR = 2.0 [1.2, 3.4], P = 0.011). Membership in the high international normalized ratio group was an independent risk factor for pneumonia (OR = 6.3 [2.5, 16.1], P 48 hours (OR = 6.5 [2.3, 18.4], P 48 hours (OR = 4.8 [1.9, 12.4], P = 0.001), cerebrovascular accident/stroke with neurological deficit (OR = 24.8 [2.9, 210.6], P = 0.003), bleeding transfusion (OR = 2.1 [1.1, 4.1], P = 0.032), reoperation (OR = 3.6 [1.4, 9.3], P = 0.008), and sepsis (OR = 3.4 [1.1, 10.4], P = 0.031). This is the first large study to document abnormal coagulation profile as an independent predictor of outcomes following PCLF. Abnormal coagulation profile represents a predictor of complications that can be medically mitigated, and is therefore a valuable parameter to assess preoperatively. Coagulation profile should continue to play a role in targeting patients for risk stratification, preoperative optimization, and

  3. Coagulation profile of children with sickle cell anemia in steady state ...

    African Journals Online (AJOL)

    Background: Sickle cell anemia is associated with a hypercoagulable state that may lead to alterations in a coagulation profile. Measurements of coagulation factors are known to have some predictive value for clinical outcome. Objectives: To determine the coagulation profile of children with SCA in steady state and crisis ...

  4. Coagulation Profile as a Risk Factor for 30-Day Morbidity and Mortality Following Posterior Lumbar Fusion.

    Science.gov (United States)

    Bronheim, Rachel S; Oermann, Eric K; Cho, Samuel K; Caridi, John M

    2017-06-15

    A retrospective cohort study. The aim of this study was to identify associations between abnormal coagulation profile and postoperative morbidity and mortality in patients undergoing posterior lumbar fusion (PLF). The literature suggests that abnormal coagulation profile is associated with postoperative complications, notably the need for blood transfusion. However, there is little research that directly addresses the influence of coagulation profile on postoperative complications following PLF. The American College of Surgeons National Surgical Quality Improvement Program database (ACS-NSQIP) was utilized to identify patients undergoing PLF between 2006 and 2013. Nine thousand two hundred ninety-five patients met inclusion criteria. Multivariate analysis was utilized to identify associations between abnormal coagulation profile and postoperative complications. Low platelet count was an independent risk factor for organ space surgical site infections (SSIs) [odds ratio (OR) = 6.0, P 48 hours (OR = 4.5, P = 0.002), Acute renal failure (OR = 5.8, P = 0.007), transfusion (OR = 1.6, P risk factor for ventilation >48 hours (OR = 5.6, P = 0.002), cerebrovascular accident (CVA)/stroke with neurological deficit (OR = 5.1, P = 0.011), cardiac arrest (OR = 5.4, P = 0.030), transfusion (OR = 1.5, P = 0.020), and death (OR = 4.5, P = 0.050). High International Normalized Ration (INR) was an independent risk factor for pneumonia (OR = 8.7, P = 0.001), pulmonary embolism (OR = 5.6, P = 0.021), deep venous thrombosis/Thrombophlebitis (OR = 4.8, P = 0.011), septic shock (OR = 8.4, P = 0.048), and death (OR = 9.8, P = 0.034). Bleeding disorder was an independent risk factor for organ space SSI (OR = 5.4, P = 0.01), pneumonia (OR = 3.0, P = 0.023), and sepsis (OR = 4.4, P profile was an independent predictor of morbidity and mortality in patients

  5. Coagulation Profile in Patients with Different Etiologies for Cushing Syndrome: A Prospective Observational Study.

    Science.gov (United States)

    Tirosh, Amit; Lodish, Maya; Lyssikatos, Charalampos; Belyavskaya, Elena; Feelders, Richard A; Stratakis, Constantine A

    2017-05-01

    Previous studies reported a higher prevalence of venous-thromboembolic events among patients with Cushing disease (CD) compared to those with ACTH-independent Cushing syndrome (CS) from adrenal sources. The objective of the current study was to evaluate the coagulation profile of patients with CS from different etiologies. A prospective observational study was conducted at a clinical research center. The study included adult patients admitted for evaluation of suspected CS (n=85), that were divided into 3 groups: CD (n=22), ACTH-independent CS from an adrenal tumor/hyperplasia (adrenal CS, n=21), and a control group consisting of subjects with negative screening for CS (rule-out CS, n=42). Coagulation profiles were drawn before and 8.5±4.3 months after surgery (trans-sphenoidal or adrenalectomy, n=18), and included fibrinogen, Factor VIII (FVIII), von Willebrand factor antigen (vWF:Ag), plasminogen activator inhibitor-1 (PAI-1), antithrombin III (ATIII), Protein C (PC), Protein S (PS), α2-antiplasmin (α2AP), and aPTT measurements. Patients with CD had higher baseline mean cortisol levels, ATIII activity and vWF:Ag levels compared with adrenal CS. Differences in ATIII activity and vWF:Ag levels remained even after controlling for BMI, and ATIII after also controlling for 24-h urinary free cortisol collections. Our study showed for the first time the differences in coagulation profiles between various etiologies of CS. We assume that the higher cortisol burden among CD patients may explain the differences found in the coagulation profile as well as the higher risk for VTE compared with primary adrenal CS patients. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Influence of vegetable coagulant and ripening time on the lipolytic and sensory profile of cheeses made with raw goat milk from Canary breeds.

    Science.gov (United States)

    Rincón, Arturo A; Pino, Verónica; Fresno, María R; Jiménez-Abizanda, Ana I; Álvarez, Sergio; Ayala, Juan H; Afonso, Ana M

    2017-04-01

    Free fatty acids and sensory profiles were obtained for cheeses made with raw goat milk and vegetable coagulant, derived from the cardoon flower ( Cynara cardunculus), at different ripening times (7 and 20 days). A solid-liquid phase extraction method followed by solid-phase extraction and gas chromatography was used. Profiles were also obtained with cheeses made with commercial coagulant, traditional kid rennet paste, and mixture coagulant (vegetable coagulant-kid rennet). The use of vegetable coagulant and vegetable coagulant-kid rennet is common in traditional Protected Designation of Origin cheeses such as " Queso Flor de Guía" and " Queso Media Flor de Guía" (Spain). Contents of short-chain free fatty acids (7.5-22.5 mmol·kg -1 ), medium-chain free fatty acids (0.4-3.7 mmol·kg -1 ), and long-chain free fatty acids (0.2-2.1 mmol·kg -1 ) varied depending on the coagulant type and the ripening time. Vegetable coagulant cheeses present odour intensity and flavour intensity much higher than commercial coagulant cheeses in the sensory analysis for cheeses obtained with seven days of ripening, but the values decrease when increasing the ripening time. Multivariate analysis allowed us to differentiate cheese samples according to the ripening time when using lipolytic profile and according to the coagulant type using the sensory profile.

  7. Evaluation of Coagulation Profiles in Dogs with Septic Shock

    OpenAIRE

    YILMAZ, Zeki; YALÇIN, Ebru

    2002-01-01

    The aim of the this study was to observe possible changes in coagulation profiles in dogs with septic shock. A total of 30 dogs (control group n=10, test group n=20) were used as materials in this study. Although different diseases leading to septic shock were diagnosed in dogs in the test group, dogs were selected on the basis of septic shock criteria such as fever or hypothermia, hypotension, leukopenia or leukocytosis and thrombocytopenia. In addition to the results of rutine clinical and...

  8. C-reactive protein in patients with acute coronary syndrome: association with coronary markers, lipid profile and markers of coagulation

    International Nuclear Information System (INIS)

    Munir, T.A.; Afzal, M.N.

    2010-01-01

    To determine levels of C-reactive protein (CRP) and its association with coronary markers, lipid profile and markers of coagulation in patients of acute coronary syndrome (ACS). The study was conducted at Shifa college of Medicine and Shifa international hospital for a period of one year (November 2005-December 2006). Patients and Methods: Sixty nine age matched controls and 133 consecutive patients of ACS were included in the study. CRP were measured by immunoturbidometric method, MB fraction of creatine kinase (CK-MB) and Troponin-1 by micro-particle enzyme immunoassay, lipid levels by Colorimetric Enzymatic methods, platelets by celldyn and coagulation markers were measured by CA-50 Sysmax. At admission mean CRP levels, cardiac biomarkers, lipid profile and coagulation markers were significantly increased in patients of ACS versus controls. Within the patients of ACS the mean levels of CRP, CK-MB, Trop I, prothrombin time (PT) and activated partial thromboplastin time (Am) were significantly raised in patients with ST - elevation myocardial infarction (STEMI) and non STEMI (NSTEMI) versus patients of unstable angina (VA). Association between CRP levels and coronary markers, coagulation markers and lipid profile was found to be non significant. The CRP levels were increased in patients with ACS as compared to controls. The CRP levels were insignificantly correlated with coronary markers (CK-MB, Trop I), coagulation markers (platelet count, PT, Am), and lipid profile (cholesterol, triglyceride, HDL and LDL cholesterol) in patients with ACS. (author)

  9. Coagulation profile in patients undergoing video-assisted thoracoscopic lobectomy: A randomized, controlled trial.

    Directory of Open Access Journals (Sweden)

    Thomas Decker Christensen

    Full Text Available Knowledge about the impact of Low-Molecular-Weight Heparin (LMWH on the coagulation system in patients undergoing minimal invasive lung cancer surgery is sparse. The aim of this study was to assess the effect of LMWH on the coagulation system in patients undergoing Video-Assisted Thoracoscopic Surgery (VATS lobectomy for primary lung cancer.Sixty-three patients diagnosed with primary lung cancer undergoing VATS lobectomy were randomized to either subcutaneous injection with dalteparin (Fragmin® 5000 IE once daily or no intervention. Coagulation was assessed pre-, peri-, and the first two days postoperatively by standard coagulation blood test, thromboelastometry (ROTEM® and thrombin generation.Patients undergoing potential curative surgery for lung cancer were not hypercoagulable preoperatively. There was no statistically significant difference in the majority of the assessed coagulation parameters after LMWH, except that the no intervention group had a higher peak thrombin and a shorter INTEM clotting time on the first postoperative day and a lower fibrinogen level on the second postoperative day. A lower level of fibrin d-dimer in the LMWH group was found on the 1. and 2.postoperative day, although not statistical significant. No differences were found between the two groups in the amount of bleeding or number of thromboembolic events.Use of LMWH administered once daily as thromboprophylaxis did not alter the coagulation profile per se. As the present study primarily evaluated biochemical endpoints, further studies using clinical endpoints are needed in regards of an optimized thromboprophylaxis approach.

  10. Haematology and coagulation profiles in cats with congenital portosystemic shunts.

    Science.gov (United States)

    Tzounos, Caitlin E; Tivers, Michael S; Adamantos, Sophie E; English, Kate; Rees, Alan L; Lipscomb, Vicky J

    2017-12-01

    Objectives The objectives of this study were, first, to report the haematological parameters and coagulation times for cats with a congenital portosystemic shunt (CPSS) and the influence of surgical shunt attenuation on these parameters; and, second, to identify any association between prolongation in coagulation profiles and incidence of perioperative haemorrhage. Methods This was a retrospective clinical study using client-owned cats with a CPSS. Signalment, shunt type (extra- or intrahepatic), degree of shunt attenuation (complete or partial), haematological parameters, prothrombin time (PT) and activated partial thromboplastin time (aPTT) test results, and occurrence of any perioperative clinical bleeding complications were recorded for cats undergoing surgical treatment of a CPSS at the Royal Veterinary College, UK, between 1994 and 2011. Results Forty-two cats were included. Thirty-six (85.7%) had an extrahepatic CPSS and six (14.3%) had an intrahepatic CPSS. Preoperatively, mean cell volume (MCV) and mean cell haemoglobin (MCH) were below the reference interval (RI) in 32 (76.2%) and 31 (73.8%) cats, respectively. Red blood cell count and mean cell haemoglobin concentration (MCHC) were above the RI in 10 (23.8%) and eight (19.1%) cats, respectively. Postoperatively, there were significant increases in haematocrit ( P = 0.044), MCV ( P = 0.008) and MCH ( P = 0.002). Despite the significant increase in MCV postoperatively, the median MCV postoperatively was below the RI, indicating persistence of microcytosis. Preoperatively, PT was above the upper RI in 14 cats (87.5%), and aPTT was above the upper RI in 11 cats (68.8%). No cat demonstrated a perioperative clinical bleeding complication. Conclusions and relevance Cats with a CPSS are likely to present with a microcytosis, but rarely present with anaemia, leukocytosis or thrombocytopenia. Surgical attenuation of the CPSS results in a significant increase in the HCT and MCV. Coagulation profiles in cats with a

  11. Normal saline influences coagulation and endothelial function after traumatic brain injury and hemorrhagic shock in pigs

    DEFF Research Database (Denmark)

    Dekker, Simone E; Sillesen, Martin; Bambakidis, Ted

    2014-01-01

    ), colloids (Hextend [HEX]), and fresh frozen plasma (FFP) resuscitation are associated with differential effects on coagulation and endothelial systems. METHODS: We subjected 15 Yorkshire swine to TBI and HS (40% blood volume), and kept in HS for 2 hours before resuscitation with NS, HEX, or FFP. Markers......BACKGROUND: Traumatic brain injury (TBI) and hemorrhagic shock (HS) are the leading causes of trauma-related deaths. These insults disrupt coagulation and endothelial systems. This study investigated whether previously reported differences in lesion size and brain swelling during normal saline (NS...... of endothelial activation (E-selectin, Intercellular adhesion molecule [ICAM]-1), coagulation activation (prothrombin fragment 1 + 2), and natural anticoagulation (activated protein C [aPC]) were determined in serum and brain whole cell lysates. RESULTS: Serum levels of aPC were greater in the NS group (203 ± 30...

  12. COAGULATION PROFILE IN PATIENTS PRESENTING WITH MALIGNANCIES WITH SPECIAL REFERENCES TO HEAD AND NECK EPITHELIAL CANCERS, LEUKAEMIAS AND LYMPHOMAS

    Directory of Open Access Journals (Sweden)

    Kaberee Bhuyan

    2016-04-01

    Full Text Available BACKGROUND Cancer can cause activation of coagulation in many ways and there is definite evidence of abnormalities in haemostatic mechanism which is seen by the presence of one or more circulating markers of haemostatic activation & this is found to be potentiated by the release of tissue factors or procoagulants from normal tissue destructions during tumour development. OBJECTIVES • To evaluate the range of different types of haemostatic abnormalities in haematological and epithelial malignancies, especially the head and neck epithelial malignancies. • To look for the differences in the grades of these abnormalities in metastatic & non-metastatic malignancies. • To understand the prognostic value of routine tests of coagulation while predicting the outcome of the patient. • MATERIALS AND METHODS The study was conducted in the Department of Pathology, Gauhati Medical College & Hospital, Guwahati from July 2004 to June 2005. 70 cases comprising of head and neck epithelial malignancies, leukaemias and lymphomas without clinical presentation of haemorrhage or thrombosis were selected and coagulation profiles were seen. RESULTS AND OBSERVATION Out of 70 cases of both sexes & different age groups prior to therapeutic intervention, metastatic cases were 22, non-metastatic cases were 29, and 19 cases belonged to leukaemias and lymphomas. The commonest age group affected was 51–60 yrs. and male: female was 3.7: 1. The most frequent abnormality was 41 cases (58.57% of FDP positivity in the serum followed by 36 cases (51.43% of hyperfibrinogenaemia; 32 cases (45.71% shortened bleeding time, etc. DISCUSSION Activated coagulation in cancer leads to increased fibrin deposition stimulated by the destroyed tissues; increased FDPs being a strong marker of coagulation and fibrinolytic activation; increased platelet aggregation by the micro vesicles shed by tumour cells; prolonged PT & APTT being well known markers for disseminated intravascular

  13. Blood coagulation parameters and platelet indices: changes in normal and preeclamptic pregnancies and predictive values for preeclampsia.

    Directory of Open Access Journals (Sweden)

    Lei Han

    Full Text Available Preeclampsia (PE is an obstetric disorder with high morbidity and mortality rates but without clear pathogeny. The dysfunction of the blood coagulation-fibrinolysis system is a salient characteristic of PE that varies in severity, and necessitates different treatments. Therefore, it is necessary to find suitable predictors for the onset and severity of PE.We aimed to evaluate blood coagulation parameters and platelet indices as potential predictors for the onset and severity of PE.Blood samples from 3 groups of subjects, normal pregnant women (n = 79, mild preeclampsia (mPE (n = 53 and severe preeclampsia (sPE (n = 42, were collected during early and late pregnancy. The levels of coagulative parameters and platelet indices were measured and compared among the groups. The receiver-operating characteristic (ROC curves of these indices were generated, and the area under the curve (AUC was calculated. The predictive values of the selected potential parameters were examined in binary regression analysis.During late pregnancy in the normal pregnancy group, the activated partial thromboplastin time (APTT, prothrombin time (PT, thrombin time (TT and platelet count decreased, while the fibrinogen level and mean platelet volume (MPV increased compared to early pregnancy (p<0.05. However, the PE patients presented with increased APTT, TT, MPV and D-dimer (DD during the third trimester. In the analysis of subjects with and without PE, TT showed the largest AUC (0.743 and high predictive value. In PE patients with different severities, MPV showed the largest AUC (0.671 and ideal predictive efficiency.Normal pregnancy causes a maternal physiological hypercoagulable state in late pregnancy. PE may trigger complex disorders in the endogenous coagulative pathways and consume platelets and FIB, subsequently activating thrombopoiesis and fibrinolysis. Thrombin time and MPV may serve as early monitoring markers for the onset and severity of PE

  14. Coagulation profile in open and video-assisted thoracoscopic lobectomies

    DEFF Research Database (Denmark)

    Christensen, Thomas Decker; Vad, Henrik; Pedersen, Søren

    2018-01-01

    OBJECTIVES: Lung cancer patients are perceived to have a relatively high risk of venous thromboembolic events due to an activation of the coagulation system. In terms of activation of the coagulation system, the difference between video-assisted thoracoscopic surgery (VATS) and open lobectomies...... for primary lung cancer has not been investigated. The aim of this study was to compare the impact on the coagulation system in patients undergoing curative surgery for primary lung cancer by either VATS or open lobectomies. METHODS: In total, 62 patients diagnosed with primary lung cancer were allocated...... to either VATS (n = 32) or open lobectomies (n = 30). All patients received subcutaneous injections with dalteparin (Fragmin®) 5000 IE once daily. The coagulation was assessed pre- and intraoperatively, and the first 2 days postoperatively by standard coagulation blood tests, thromboelastometry (ROTEM...

  15. Coagulation parameters as a guide for fresh frozen plasma transfusion practice: A tertiary hospital experience

    Directory of Open Access Journals (Sweden)

    Wan Haslindawani W

    2010-01-01

    Full Text Available Introduction: The appropriate use of blood and blood products means the transfusion of safe blood products only to treat a condition leading to significant morbidity or mortality, which cannot be prevented or managed effectively by other means. The safety and effectiveness of transfusion depend on the appropriate clinical use of blood and blood products. This study was conducted to review the practice of fresh frozen plasma usage (FFP for transfusion, based on the coagulation profile, requested by various departments in the Hospital Universiti Sains Malaysia (HUSM. Methodology: A retrospective review of blood bank records and coagulation profile results of the patients given FFP from October to December 2006, in Hospital USM was undertaken. The criteria set by the College of American Pathologists in 1994, were used as the guidelines. Results: One thousand six hundred and ninety-eight units of FFP were used during this study period. Only 806 (47.47% FFP units were deemed appropriate. 20.38% were based on studies without any coagulation tests prior to transfusion and 21.13% were transfused for mild prolongation of coagulation test results. About 6.41% requested FFP in the setting of normal coagulation results. Conclusion: Our results showed that a significant proportion of the FFP transfusion was not guided by the coagulation profile. We recommend that a continuous education on FFP transfusion may help to guide the appropriate request for FFP.

  16. Coagulation profile in patients undergoing video-assisted thoracoscopic lobectomy

    DEFF Research Database (Denmark)

    Christensen, Thomas Decker; Vad, Henrik; Pedersen, Søren

    2017-01-01

    -, and the first two days postoperatively by standard coagulation blood test, thromboelastometry (ROTEM®) and thrombin generation. Results: Patients undergoing potential curative surgery for lung cancer were not hypercoagulable preoperatively. There was no statistically significant difference in the majority......Background: Knowledge about the impact of Low-Molecular-Weight Heparin (LMWH) on the coagulation system in patients undergoing minimal invasive lung cancer surgery is sparse. The aim of this study was to assess the effect of LMWH on the coagulation system in patients undergoing Video......-Assisted Thoracoscopic Surgery (VATS) lobectomy for primary lung cancer. Methods: Sixty-three patients diagnosed with primary lung cancer undergoing VATS lobectomy were randomized to either subcutaneous injection with dalteparin (Fragmin®) 5000 IE once daily or no intervention. Coagulation was assessed pre-, peri...

  17. Overview of the coagulation system.

    Science.gov (United States)

    Palta, Sanjeev; Saroa, Richa; Palta, Anshu

    2014-09-01

    Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms 'coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same.

  18. Overview of the coagulation system

    Directory of Open Access Journals (Sweden)

    Sanjeev Palta

    2014-01-01

    Full Text Available Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms ′coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same.

  19. A single-dose of oral nattokinase potentiates thrombolysis and anti-coagulation profiles.

    Science.gov (United States)

    Kurosawa, Yuko; Nirengi, Shinsuke; Homma, Toshiyuki; Esaki, Kazuki; Ohta, Mitsuhiro; Clark, Joseph F; Hamaoka, Takafumi

    2015-06-25

    Our aim was to determine the quantitative effects of a single-dose of Nattokinase (NK) administration on coagulation/fibrinolysis parameters comprehensively in healthy male subjects. A double-blind, placebo-controlled cross-over NK intervention study was carried out in 12 healthy young males. Following the baseline blood draw, each subject was randomized to receive either a single-dose of 2,000 FU NK (NSK-SD, Japan Bio Science Laboratory Co., Ltd) or placebo with subsequent cross-over of the groups. Subjects donated blood samples at 2, 4, 6 and 8 hours following administration for analysis of coagulation/fibrinolysis parameters. As a result, D-dimer concentrations at 6, and 8 hours, and blood fibrin/fibrinogen degradation products at 4 hours after NK administration elevated significantly (p < 0.05, respectively). Factor VIII activity declined at 4 and 6 hours (p < 0.05, respectively), blood antithrombin concentration was higher at 2 and 4 hours (p < 0.05, respectively), and the activated partial thromboplastin time prolonged significantly at 2 and 4 hours following NK administration (p < 0.05 and p < 0.01, respectively). All the changes, however, were within the normal range. In conclusion, thus, a single-dose of NK administration appears enhancing fibrinolysis and anti-coagulation via several different pathways simultaneously.

  20. Thermal coagulation-induced changes of the optical properties of normal and adenomatous human colon tissues in vitro in the spectral range 400-1100 nm

    International Nuclear Information System (INIS)

    Ao Huilan; Xing Da; Wei Huajiang; Gu Huaimin; Wu Guoyong; Lu Jianjun

    2008-01-01

    The absorption coefficients, the reduced scattering coefficients and the optical penetration depths for native and coagulated human normal and adenomatous colon tissues in vitro were determined over the range of 400-1100 nm using a spectrophotometer with an internal integrating sphere system, and the inverse adding-doubling method was applied to calculate the tissue optical properties from diffuse reflectance and total transmittance measurements. The experimental results showed that in the range of 400-1100 nm there were larger absorption coefficients (P < 0.01) and smaller reduced scattering coefficients (P < 0.01) for adenomatous colon tissues than for normal colon tissues, and there were smaller optical penetration depths for adenomatous colon tissues than for normal colon tissues, especially in the near-infrared wavelength. Thermal coagulation induced significant increase of the absorption coefficients and reduced scattering coefficients for the normal and adenomatous colon tissues, and significantly reduced decrease of the optical penetration depths for the normal and adenomatous colon tissues. The smaller optical penetration depth for coagulated adenomatous colon tissues is a disadvantage for laser-induced thermotherapy (LITT) and photodynamic therapy (PDT). It is necessary to adjust the application parameters of lasers to achieve optimal therapy

  1. An updated concept of coagulation with clinical implications.

    Science.gov (United States)

    Romney, Gregory; Glick, Michael

    2009-05-01

    Over the past century, a series of models have been put forth to explain the coagulation mechanism. The coagulation cascade/waterfall model has gained the most widespread acceptance. This model, however, has problems when it is used in different clinical scenarios. A more recently proposed cell-based model better describes the coagulation process in vivo and provides oral health care professionals (OHCPs) with a better understanding of the clinical implications of providing dental care to patients with potentially increased bleeding tendencies. The authors conducted a literature search using the PubMed database. They searched for key words including "coagulation," "hemostasis," "bleeding," "coagulation factors," "models," "prothrombin time," "activated partial thromboplastin time," "international normalized ratio," "anticoagulation therapy" and "hemophilia" separately and in combination. The coagulation cascade/waterfall model is insufficient to explain coagulation in vivo, predict a patient's bleeding tendency, or correlate clinical outcomes with specific laboratory screening tests such as prothrombin time, activated partial thromboplastin time and international normalized ratio. However, the cell-based model of coagulation that reflects the in vivo process of coagulation provides insight into the clinical ramifications of treating dental patients with specific coagulation factor deficiencies. Understanding the in vivo coagulation process will help OHCPs better predict a patient's bleeding tendency. In addition, applying the theoretical concept of the cell-based model of coagulation to commonly used laboratory screening tests for coagulation and bleeding will result in safer and more appropriate dental care.

  2. Histopathological investigation of radiation necrosis. Coagulation necrosis in the irradiated and non-irradiated brain tumors and in the normal brain tissue

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, N [Niigata Univ. (Japan). Brain Research Inst.

    1977-01-01

    Eighty four irradiated tumors (including 59 gliomas) and the surrounding brain tissue were analyzed. In 'normal' brain tissue, typical coagulation necrosis attributable to irradiation was observed in the cerebral white matter, presenting a whitish-yellow color but no remarkable changes in volume. Histologically there was complete desintegration of myelin and axon. Vascular changes included hyalinous thickening, concentric cleavage, fibrinoid degeneration, adventitial fibrosis and edema of small arteries, fibrin thrombi or occlusion of arterioles and capillaries, and telangiectasia of small veins and venules. While other tumors showed hyalinous or fibrous scar tissue and decrease in volume, the gliomas maintained their original volume without residual tumor cells. Massive coagulation necrosis was occasionally found even in full volume, non-irradiated gliomas (controls), although the changes were fewer and not so varied as in typical radiation necrosis. With small dosages, it was difficult to judge whether the necrosis was caused by irradiation or occurred spontaneously. Coagulation necrosis in tumor tissue was found in 25 of 59 cases (42%) of irradiated gliomas, but in only 2 of 49 cases (4%) of the nonirradiated gliomas. In 49 cases no coagulation necrosis of the surrounding tissue was found. Although histopathological judgement is difficult, it is suggested that there is a significant correlation between coagulation necrosis and irradiation. Discussion of the relationship between coagulation necrosis and NSD (nominal standard dose) led to the conclusion that coagulation necrosis will not be caused by irradiation of less than 1400 rets in NSD.

  3. In vitro evaluation of the effect of haemodilution with dextran 40 on coagulation profile as measured by thromboelastometry and multiple electrode aggregometry.

    Science.gov (United States)

    Kam, Pca; Liou, Jpc; Yang, Kxf

    2017-09-01

    We evaluated the effects of haemodilution with either dextran 40 or 0.9% normal saline on coagulation in vitro using rotational thromboelastometry (ROTEM®, Pentapharm Co., Munich, Germany) and multiple electrode aggregometry (Multiplate® Platelet Function Analyser, Dynabyte, Munich, Germany). Venous blood samples obtained from 20 healthy volunteers were diluted in vitro with dextran 40 or normal saline by 5%, 10% and 15%. Fibrinogen concentration, ROTEM-EXTEM® (screening test for the extrinsic coagulation pathway), FIBTEM® (an EXTEM-based assay of the fibrin component of clot) parameters including coagulation time, clot formation time, alpha angle, maximum clot firmness and lysis index were measured in the undiluted sample and at each level of haemodilution. Dextran 40 at 15% haemodilution significantly prolonged coagulation time, clot formation time and significantly decreased the alpha angle and maximal clot firmness (EXTEM amplitude at five minutes [A5] and ten minutes [A10]) compared with normal saline. The FIBTEM assay (maximal clot firmness and FIBTEM A5 and A10) showed a marked decrease in maximal clot firmness at all dilutions suggesting impaired fibrinogen activity and a risk of bleeding. Multiple electrode aggregometry did not demonstrate any platelet dysfunction. Haemodilution with dextran 40 causes significant impairment in clot formation and strength compared to saline haemodilution and undiluted blood. At the levels of in vitro haemodilution designed to reflect the clinical use of dextran infusions, no significant fibrinolysis or platelet inhibition was observed.

  4. Physiological levels of blood coagulation factors IX and X control coagulation kinetics in an in vitro model of circulating tissue factor

    International Nuclear Information System (INIS)

    Tormoen, Garth W; Khader, Ayesha; Gruber, András; McCarty, Owen J T

    2013-01-01

    Thrombosis significantly contributes to cancer morbidity and mortality. The mechanism behind thrombosis in cancer may be circulating tissue factor (TF), as levels of circulating TF are associated with thrombosis. However, circulating TF antigen level alone has failed to predict thrombosis in patients with cancer. We hypothesize that coagulation factor levels regulate the kinetics of circulating TF-induced thrombosis. Coagulation kinetics were measured as a function of individual coagulation factor levels and TF particle concentration. Clotting times increased when pooled plasma was mixed at or above a ratio of 4:6 with PBS. Clotting times increased when pooled plasma was mixed at or above a ratio of 8:2 with factor VII-depleted plasma, 7:3 with factor IX- or factor X-depleted plasmas, or 2:8 with factor II-, V- or VIII-depleted plasmas. Addition of coagulation factors VII, X, IX, V and II to depleted plasmas shortened clotting and enzyme initiation times, and increased enzyme generation rates in a concentration-dependent manner. Only additions of factors IX and X from low-normal to high-normal levels shortened clotting times and increased enzyme generation rates. Our results demonstrate that coagulation kinetics for TF particles are controlled by factor IX and X levels within the normal physiological range. We hypothesize that individual patient factor IX and X levels may be prognostic for susceptibility to circulating TF-induced thrombosis. (paper)

  5. Comparative thermometric coagulation studies of plasmas from normal outbred Swiss Webster mice and persons.

    Science.gov (United States)

    Tsang, V C; Wyatt, C R; Damian, R T

    1979-06-01

    The functional capabilities of a thermometric clot-timer have been demonstrated in a comparative study of human and mouse plasma coagulation. The influence of some variables on coagulation times of mouse and human plasmas were examined in activated partial thromboplastin time, one-stage prothrombin time, and Russell's viper venom time assays. Mouse plasma coagulation times were generally shorter and more reproducible than those of human plasma. Optimal assay conditions are also described.

  6. Magnetic particle imaging of blood coagulation

    Energy Technology Data Exchange (ETDEWEB)

    Murase, Kenya, E-mail: murase@sahs.med.osaka-u.ac.jp; Song, Ruixiao; Hiratsuka, Samu [Department of Medical Physics and Engineering, Division of Medical Technology and Science, Faculty of Health Science, Graduate School of Medicine, Osaka University, Osaka 565-0871 (Japan)

    2014-06-23

    We investigated the feasibility of visualizing blood coagulation using a system for magnetic particle imaging (MPI). A magnetic field-free line is generated using two opposing neodymium magnets and transverse images are reconstructed from the third-harmonic signals received by a gradiometer coil, using the maximum likelihood-expectation maximization algorithm. Our MPI system was used to image the blood coagulation induced by adding CaCl{sub 2} to whole sheep blood mixed with magnetic nanoparticles (MNPs). The “MPI value” was defined as the pixel value of the transverse image reconstructed from the third-harmonic signals. MPI values were significantly smaller for coagulated blood samples than those without coagulation. We confirmed the rationale of these results by calculating the third-harmonic signals for the measured viscosities of samples, with an assumption that the magnetization and particle size distribution of MNPs obey the Langevin equation and log-normal distribution, respectively. We concluded that MPI can be useful for visualizing blood coagulation.

  7. Comparative Proteomic Profile of the Human Umbilical Cord Blood Exosomes between Normal and Preeclampsia Pregnancies with High-Resolution Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Ruizhe Jia

    2015-07-01

    Full Text Available Background/Aims: Exosomes are extracellular vesicles that are involved in several biological processes. The roles of proteins from human umbilical cord blood exosomes in the pathogenesis of preeclampsia remains poorly understood. Methods: In this study, we used high-resolution LC-MS/MS technologies to construct a comparative proteomic profiling of human umbilical cord blood exosomes between normal and preeclamptic pregnancies. Results: A total of 221 proteins were detected in human umbilical cord blood exosomes, with 14 upregulated and 15 downregulated proteins were definitively identified between preeclamptic and control pregnancies. Further bioinformatics analysis (Gene ontology and Kyoto Encyclopedia of Genes and Genomes pathway analysis indicated that these differentially expressed proteins correlate with enzyme regulator activity, binding, extracellular region, cell part, biological regulation, cellular process and complement and coagulation cascades occurring during pathological changes of preeclampsia. Conclusion: Our results show significantly altered expression profiles of proteins in human umbilical cord blood exosomes between normal and preeclampsia pregnancies. These proteins may be involved in the etiology of preeclampsia.

  8. Blood viscosity during coagulation at different shear rates

    Science.gov (United States)

    Ranucci, Marco; Laddomada, Tommaso; Ranucci, Matteo; Baryshnikova, Ekaterina

    2014-01-01

    Abstract During the coagulation process, blood changes from a liquid to a solid gel phase. These changes are reflected by changes in blood viscosity; however, blood viscosity at different shear rates (SR) has not been previously explored during the coagulation process. In this study, we investigated the viscosity changes of whole blood in 10 subjects with a normal coagulation profile, using a cone‐on‐plate viscosimeter. For each subject, three consecutive measurements were performed, at a SR of 20, 40, 80 sec−1. On the basis of the time‐dependent changes in blood viscosity, we identified the gel point (GP), the time‐to‐gel point (TGP), the maximum clot viscosity (MCV), and the clot lysis half‐time (CLH). The TGP significantly (P = 0.0023) shortened for increasing SR, and was significantly associated with the activated partial thromboplastin time at a SR of 20 sec−1 (P = 0.038) and 80 sec−1 (P = 0.019). The MCV was significantly lower at a SR of 80 sec−1 versus 40 sec−1 (P = 0.027) and the CLH significantly (P = 0.048) increased for increasing SR. These results demonstrate that measurement of blood viscosity during the coagulation process offers a number of potentially useful parameters. In particular, the association between the TGP and the activated partial thromboplastin time is an expression of the clotting time (intrinsic and common pathway), and its shortening for increasing SR may be interpreted the well‐known activating effects of SR on platelet activation and thrombin generation. Further studies focused on the TGP under conditions of hypo‐ or hypercoagulability are required to confirm its role in the clinical practice. PMID:24994896

  9. Thyroid storm with multiple organ failure, disseminated intravascular coagulation, and stroke with a normal serum FT3 level.

    Science.gov (United States)

    Harada, Yuko; Akiyama, Hisanao; Yoshimoto, Tatsuji; Urao, Yasuko; Ryuzaki, Munekazu; Handa, Michiko

    2012-01-01

    Thyroid storm is a rare disorder with a sudden onset, rapid progression and high mortality. We experienced a case of thyroid storm which had a devastating course, including multiple organ failure (MOF), severe hypoglycemia, disseminated intravascular coagulation (DIC), and stroke. It was difficult to make a diagnosis of thyroid storm in the present patient, because she did not have a history of thyroid disease and her serum FT3 level was normal. Clinicians should be aware that thyroid storm can occur even when there is an almost normal level of thyroid hormones, and that intensive anticoagulation is required for patients with atrial fibrillation to prevent stroke after thyroid storm.

  10. Fibrinogen Vicenza and Genova II: two new cases of congenital dysfibrinogenemia with isolated defect of fibrin monomer polymerization and inhibitory activity on normal coagulation.

    Science.gov (United States)

    Rodeghiero, F; Castaman, G C; Dal Belin Peruffo, A; Dini, E; Galletti, A; Barone, E; Gastaldi, G

    1987-06-03

    Two new cases of congenital dysfibrinogenemia are presented in which defective fibrin monomer polymerization and inhibitory activity on normal coagulation were observed. They have been tentatively called fibrinogen Vicenza and Genova II. The first was discovered in a family with mild bleeding diathesis, the second in an asymptomatic family. In almost all reported cases of fibrinogens with defective fibrin monomer polymerization, additional functional or structural defects have been detected. In our cases, on the contrary, detailed investigations failed to show any other abnormality. Fibrinogen Genova II is apparently identical to fibrinogen Baltimore IV, whereas fibrinogen Vicenza is similar to fibrinogen Troyes and Genova I, but also exerts an evident inhibitory activity on normal coagulation and differs from fibrinogen Genova II and Baltimore IV showing a different kinetic pattern of fibrin monomer polymerization.

  11. Effects of Puff-Adder Venom on Coagulation, Fibrinolysis and ...

    African Journals Online (AJOL)

    The in vitro and in vivo haematological effects of puffadder (Bitis arietans) venom in the baboon (Papio ursinus) with regard to its effect on coagulation, fibrinolysis and platelet aggregation were studied. There is a delay in the intrinsic coagulation mechanism with fibrinolysis and in vitro fibrinogenolysis. Normal human ...

  12. Coagulation defects in experimental hepatic injury in the dog.

    Science.gov (United States)

    Osbaldiston, G W; Hoffman, M W

    1971-04-01

    Alteration in activity of blood coagulation factors in dogs with acute hepatic injury caused by oral carbon tetrachloride dosing was studied. Coagulation Factors II, VII and IX were dramatically reduced within 48 hours but recovered to normal in the next five days. Because surgery is rarely performed on dogs with hepatic necrosis, the use of fresh whole blood tranfusion to improve the coagulation defect in hepatic injury was also studied. Transfusion was found to have only a temporary beneficial effect.

  13. STUDY OF CHANGES IN COAGULATION PROFILE OF PATIENTS UNDERGOING LAPAROSCOPIC CHOLECYSTECTOMY USING CARBON DIOXIDE PNEUMOPERITONEUM

    Directory of Open Access Journals (Sweden)

    Vasuki Rajam

    2017-04-01

    Full Text Available BACKGROUND Laparoscopic cholecystectomy is now the gold standard procedure and with over 5,00,000 procedures being done annually, laparoscopic cholecystectomy assumes a great significance in general surgical specialty. This study aims to study the effects of carbon dioxide pneumoperitoneum on the coagulation system of patients undergoing laparoscopic cholecystectomy and make the surgeon aware of the detrimental effects. MATERIALS AND METHODS A prospective clinical observational study of 50 patients selected by systematic sampling method from January 2015 to September 2015 at our institution was conducted to determine the results of changes in coagulation profile of patients undergoing laparoscopic cholecystectomy using carbon dioxide pneumoperitoneum. RESULTS The mean prothrombin time of the patients before surgery is 11.83 seconds. The standard deviation was 1.008 and standard error of mean was 0.143. The mean of prothrombin time 6 hours after surgery was 11.7 seconds. The standard deviation was 0.898 and the standard error of mean being 0.127. The difference in the mean between the two groups was 0.130. The p-value was 0.0109 (<0.05. Hence, the value was statistically extremely significant. The values for D-dimer were analysed. The mean value of D-dimer before surgery is 129.78. The standard deviation was 21.01 and standard error of mean was at 2.97. In the D-dimer values after surgery, mean was calculated to be 350.22 with the standard deviation at 73.21 and standard error of mean at 10.35. CONCLUSION Our study concluded that there is activation of both coagulation and fibrinolytic systems post laparoscopic cholecystectomy.

  14. Multipurpose HTS Coagulation Analysis: Assay Development and Assessment of Coagulopathic Snake Venoms

    Directory of Open Access Journals (Sweden)

    Kristina B. M. Still

    2017-11-01

    Full Text Available Coagulation assays currently employed are often low throughput, require specialized equipment and/or require large blood/plasma samples. This study describes the development, optimization and early application of a generic low-volume and high-throughput screening (HTS assay for coagulation activity. The assay is a time-course spectrophotometric measurement which kinetically measures the clotting profile of bovine or human plasma incubated with Ca2+ and a test compound. The HTS assay can be a valuable new tool for coagulation diagnostics in hospitals, for research in coagulation disorders, for drug discovery and for venom research. A major effect following envenomation by many venomous snakes is perturbation of blood coagulation caused by haemotoxic compounds present in the venom. These compounds, such as anticoagulants, are potential leads in drug discovery for cardiovascular diseases. The assay was implemented in an integrated analytical approach consisting of reversed-phase liquid chromatography (LC for separation of crude venom components in combination with parallel post-column coagulation screening and mass spectrometry (MS. The approach was applied for the rapid assessment and identification of profiles of haemotoxic compounds in snake venoms. Procoagulant and anticoagulant activities were correlated with accurate masses from the parallel MS measurements, facilitating the detection of peptides showing strong anticoagulant activity.

  15. Effects on coagulation factor production following primary hepatomitogen-induced direct hyperplasia.

    Science.gov (United States)

    Tatsumi, Kohei; Ohashi, Kazuo; Taminishi, Sanae; Takagi, Soichi; Utoh, Rie; Yoshioka, Akira; Shima, Midori; Okano, Teruo

    2009-11-14

    plasma activity for both factors were consistent with our RT-PCR findings. In contrast, the plasma activities of the other coagulation factors (fibrinogen, factors V, VII, XIII, and VWF) were not significantly reduced, despite the reduction in the liver mRNA levels. Unlike the other factors, FX showed a temporal increase in its plasma activity, with significant increases (P<0.05) detected at D1. Investigating the coagulation cascade protein profiles during liver regeneration by DH may help to better understand the basic biology of the liver under normal and pathological conditions.

  16. Characterization of the coagulation profile in children with liver disease and extrahepatic portal vein obstruction or shunt.

    Science.gov (United States)

    Beattie, William; Magnusson, Maria; Hardikar, Winita; Monagle, Paul; Ignjatovic, Vera

    2017-03-01

    Chronic liver disease causes a disruption of procoagulant and anticoagulant factors, resulting in a fragile state, prone to increased rates of both bleeding and thrombosis. Currently, there is limited literature describing the changes observed in pediatric liver disease and extrahepatic portal vein obstruction or shunt. This study aimed to describe the changes that occur in children with chronic liver disease and extrahepatic portal vein obstruction or shunt. We measured the concentration and activity of key procoagulant and anticoagulant factors in children with liver disease, children with extrahepatic portal vein obstruction or shunt, and healthy children. Children with severe liver disease had coagulopathic changes, including either decreased concentration or activity of factor II, factor V, and factor VII. Nineteen percent (8/42) of the cohort had significant bleeding. Thrombophilic changes were also observed, including decreased concentration or activity of protein C, protein S, and antithrombin and increased concentration and activity of factor VIII and Von Willebrand factor. Similar coagulation factor changes were observed in children with extrahepatic portal vein obstruction or shunt. There was a trend toward greater changes in coagulation factor activity compared to concentration. This study provides a detailed description of the changes in both the concentration and activity of coagulation factors in pediatric liver disease and extrahepatic portal vein obstruction or shunt. Interestingly, procoagulant and anticoagulant factors were deranged in portal vein obstruction or shunt to a similar degree as in liver disease. An improved understanding of the coagulation profile in the pediatric setting will contribute to the improved management of liver disease and extrahepatic portal obstruction or shunt. PELD: pediatric end-stage liver disease score; MELD: model for end-stage liver disease score; ELISA: enzyme-linked immunosorbent assay; MCRI: Murdoch Childrens

  17. Coagulation Profile Changes Due to Thromboprophylaxis and Platelets in Trauma Patients at High-Risk for Venous Thromboembolism.

    Science.gov (United States)

    Allen, Casey J; Murray, Clark R; Meizoso, Jonathan P; Ray, Juliet J; Teisch, Laura F; Ruiz, Xiomara D; Hanna, Mena M; Guarch, Gerardo A; Manning, Ronald J; Livingstone, Alan S; Ginzburg, Enrique; Schulman, Carl I; Namias, Nicholas; Proctor, Kenneth G

    2015-07-01

    We hypothesize there are coagulation profile changes associated both with initiation of thromboporphylaxis (TPX) and with change in platelet levels in trauma patients at high-risk for venous thromboembolism (VTE). A total of 1203 trauma intensive care unit patients were screened with a VTE risk assessment profile. In all, 302 high-risk patients (risk assessment profile score ≥ 10) were consented for weekly thromboelastography. TPX was initiated between initial and follow-up thromboelastography. Seventy-four patients were analyzed. Upon admission, 87 per cent were hypercoagulable, and 81 per cent remained hypercoagulable by Day 7 (P = 0.504). TPX was initiated 3.4 ± 1.4 days after admission; 68 per cent received unfractionated heparin and 32 per cent received low-molecular-weight heparin. The VTE rate was 18 per cent, length of stay 38 (25-37) days, and mortality of 17.6 per cent. In all, 76 per cent had a rapid clotting time at admission versus 39 per cent at Day 7 (P < 0.001); correcting from 7.75 (6.45-8.90) minutes to 10.45 (7.90-15.25) minutes (P < 0.001). At admission, 41 per cent had an elevated maximum clot formation (MCF) and 85 per cent had at Day 7 (P < 0.001); increasing from 61(55-65) mm to 75(69-80) mm (P < 0.001). Platelets positively correlated with MCF at admission (r = 0.308, R(2) = 0.095, P = 0.008) and at Day 7 (r = 0.516, R(2) = 0.266, P < 0.001). Change in platelet levels correlated with change in MCF (r = 0.332, R(2) = 0.110, P = 0.005). In conclusion, hypercoagulability persists despite the use of TPX. Although clotting time normalizes, MCF increases in correlation with platelet levels. As platelet function is a dominant contributor to sustained trauma-evoked hypercoagulability, antiplatelet therapy may be indicated in the management of severely injured trauma patients.

  18. High Pressure Homogenization of Porcine Pepsin Protease: Effects on Enzyme Activity, Stability, Milk Coagulation Profile and Gel Development

    Science.gov (United States)

    Leite Júnior, Bruno Ricardo de Castro; Tribst, Alline Artigiani Lima; Cristianini, Marcelo

    2015-01-01

    This study investigated the effect of high pressure homogenization (HPH) (up to 190 MPa) on porcine pepsin (proteolytic and milk-clotting activities), and the consequences of using the processed enzyme in milk coagulation and gel formation (rheological profile, proteolysis, syneresis, and microstructure). Although the proteolytic activity (PA) was not altered immediately after the HPH process, it reduced during enzyme storage, with a 5% decrease after 60 days of storage for samples obtained with the enzyme processed at 50, 100 and 150 MPa. HPH increased the milk-clotting activity (MCA) of the enzyme processed at 150 MPa, being 15% higher than the MCA of non-processed samples after 60 days of storage. The enzyme processed at 150 MPa produced faster aggregation and a more consistent milk gel (G’ value 92% higher after 90 minutes) when compared with the non-processed enzyme. In addition, the gels produced with the enzyme processed at 150 MPa showed greater syneresis after 40 minutes of coagulation (forming a more compact protein network) and lower porosity (evidenced by confocal microscopy). These effects on the milk gel can be associated with the increment in MCA and reduction in PA caused by the effects of HPH on pepsin during storage. According to the results, HPH stands out as a process capable of changing the proteolytic characteristics of porcine pepsin, with improvements on the milk coagulation step and gel characteristics. Therefore, the porcine pepsin submitted to HPH process can be a suitable alternative for the production of cheese. PMID:25938823

  19. Performance Evaluation of the Sysmex CS-5100 Automated Coagulation Analyzer.

    Science.gov (United States)

    Chen, Liming; Chen, Yu

    2015-01-01

    Coagulation testing is widely applied clinically, and laboratories increasingly demand automated coagulation analyzers with short turn-around times and high-throughput. The purpose of this study was to evaluate the performance of the Sysmex CS-5100 automated coagulation analyzer for routine use in a clinical laboratory. The prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (APTT), fibrinogen (Fbg), and D-dimer were compared between the Sysmex CS-5100 and Sysmex CA-7000 analyzers, and the imprecision, comparison, throughput, STAT function, and performance for abnormal samples were measured in each. The within-run and between-run coefficients of variation (CV) for the PT, APTT, INR, and D-dimer analyses showed excellent results both in the normal and pathologic ranges. The correlation coefficients between the Sysmex CS-5100 and Sysmex CA-7000 were highly correlated. The throughput of the Sysmex CS-5100 was faster than that of the Sysmex CA-7000. There was no interference at all by total bilirubin concentrations and triglyceride concentrations in the Sysmex CS-5100 analyzer. We demonstrated that the Sysmex CS-5100 performs with satisfactory imprecision and is well suited for coagulation analysis in laboratories processing large sample numbers and icteric and lipemic samples.

  20. Blood coagulation in hemophilia A and hemophilia C

    NARCIS (Netherlands)

    Cawthern, K. M.; van 't Veer, C.; Lock, J. B.; DiLorenzo, M. E.; Branda, R. F.; Mann, K. G.

    1998-01-01

    Tissue factor (TF)-induced coagulation was compared in contact pathway suppressed human blood from normal, factor VIII-deficient, and factor XI-deficient donors. The progress of the reaction was analyzed in quenched samples by immunoassay and immunoblotting for fibrinopeptide A (FPA),

  1. The Coagulation Profile of End-Stage Liver Disease and Considerations for Intraoperative Management.

    Science.gov (United States)

    Forkin, Katherine T; Colquhoun, Douglas A; Nemergut, Edward C; Huffmyer, Julie L

    2018-01-01

    The coagulopathy of end-stage liver disease results from a complex derangement in both anticoagulant and procoagulant processes. With even minor insults, cirrhotic patients experience either inappropriate bleeding or clotting, or even both simultaneously. The various phases of liver transplantation along with fluid and blood product administration may contribute to additional disturbances in coagulation. Thus, anesthetic management of patients undergoing liver transplantation to improve hemostasis and avoid inappropriate thrombosis in the perioperative environment can be challenging. To add to this challenge, traditional laboratory tests of coagulation are difficult to interpret in patients with end-stage liver disease. Viscoelastic coagulation tests such as thromboelastography (Haemonetics Corporation, Braintree, MA) and rotational thromboelastometry (TEM International, Munich, Germany) have helped to reduce transfusion of allogeneic blood products, especially fresh frozen plasma, but have also lead to the increased use of fibrinogen-containing products. In general, advancements in surgical techniques and anesthetic management have led to significant reduction in blood transfusion requirements during liver transplantation. Targeted transfusion protocols and pharmacologic prevention of fibrinolysis may further aid in the management of the complex coagulopathy of end-stage liver disease.

  2. Blood coagulation in lead poisoning and the influence of specific treatment

    Energy Technology Data Exchange (ETDEWEB)

    Levantovskaya, O M; Lyubcenko, P N; Dayhin, I S; Sorkina, N S

    1974-07-01

    Results of blood coagulation studies in 104 workers with long-term exposure in a storage-battery plant. Over-all coagulation activity is unchanged in cases of mild lead poisoning, but long-term exposure gives rise to increased fibrinogen levels, activated fibrinolysis, and reduced serum accelerator globulin and prothrombin activities. 13 workers were given D-penicillamine (oral doses of 450 mg daily). All coagulation indices had become normal after 10 days' treatment. The changes observed are thought to be due to protein synthesis disturbances in the liver and to inhibition of enzymes by lead which combines with their sulfhydryl and disulfide groups. (CIS Abstr. Vol. 2)

  3. Investigation of coagulation activity of natural coagulants from seeds of different leguminose species

    Directory of Open Access Journals (Sweden)

    Šćiban Marina B.

    2005-01-01

    Full Text Available The ability of seeds of plants: Phaseolus vulgaris, Robinia pseudoacacia Ceratonia siliqua and Amorpha fruticosa, to act as natural coagulants was tested using synthetic turbid water. This water was prepared by adding kaolin into tap water, just before the test. Active components were extracted from ground seeds with distilled water. The coagulation ability of this extract was assessed by the use of standard jar test measurements in water with various initial turbidity. Investigation of these natural coagulants was confirmed their positive coagulation activity. Of all plants that have been examined, the seed extract from Ceratonia siliqua appeared to be one of the most effective coagulants for water treatment. A dose of 20 mg/l of this coagulant resulted in 100% coagulation activity for clarification of water with 17.5 NTU initial turbidity.

  4. Exogenous normal lymph alleviates microcirculation disturbances and abnormal hemorheological properties in rats with disseminated intravascular coagulation

    Energy Technology Data Exchange (ETDEWEB)

    Niu, Chun-Yu; Zhao, Zi-Gang; Zhang, Yu-Ping [Institute of Microcirculation, Hebei North University, Zhangjiakou (China); Hou, Ya-Li [Department of Clinical Laboratory, First Affiliated Hospital, Hebei North University, Zhangjiakou (China); Li, Jun-Jie; Jiang, Hua; Zhang, Jing [Institute of Microcirculation, Hebei North University, Zhangjiakou (China)

    2013-02-01

    Disturbances of the microcirculation and abnormal hemorheological properties are important factors that play an important role in disseminated intravascular coagulation (DIC) and result in organ dysfunction or failure. In the present study, we established an animal model of DIC using intravenous Dextran 500 in rats, and used exogenous normal lymph corresponding to 1/15 of whole blood volume for injection through the left jugular vein. We found that normal lymph could improve the blood pressure and survival time of rats with DIC. The results regarding the mesenteric microcirculation showed that the abnormality of the diameter of mesenteric microvessels and micro-blood flow speed in the DIC+lymph group was significantly less than in the DIC+saline group. Whole blood viscosity, relative viscosity, plasma viscosity, hematocrit (Hct), erythrocyte sedimentation rate (ESR), and electrophoresis time of erythrocytes were significantly increased in the DIC+saline group compared to the control group. The electrophoretic length and migration of erythrocytes from the DIC+saline and DIC+lymph groups were significantly slower than the control group. Blood relative viscosity, Hct, ESR, and electrophoretic time of erythrocytes were significantly increased in the DIC+lymph group compared to the control group. Whole blood viscosity, relative viscosity and reduced viscosity were significantly lower in the DIC+lymph group than in the DIC+saline group, and erythrocyte deformability index was also significantly higher than in the DIC+saline and control groups. These results suggest that exogenous normal lymph could markedly improve the acute microcirculation disturbance and the abnormal hemorheological properties in rats with DIC induced by Dextran 500.

  5. Exogenous normal lymph alleviates microcirculation disturbances and abnormal hemorheological properties in rats with disseminated intravascular coagulation

    International Nuclear Information System (INIS)

    Niu, Chun-Yu; Zhao, Zi-Gang; Zhang, Yu-Ping; Hou, Ya-Li; Li, Jun-Jie; Jiang, Hua; Zhang, Jing

    2013-01-01

    Disturbances of the microcirculation and abnormal hemorheological properties are important factors that play an important role in disseminated intravascular coagulation (DIC) and result in organ dysfunction or failure. In the present study, we established an animal model of DIC using intravenous Dextran 500 in rats, and used exogenous normal lymph corresponding to 1/15 of whole blood volume for injection through the left jugular vein. We found that normal lymph could improve the blood pressure and survival time of rats with DIC. The results regarding the mesenteric microcirculation showed that the abnormality of the diameter of mesenteric microvessels and micro-blood flow speed in the DIC+lymph group was significantly less than in the DIC+saline group. Whole blood viscosity, relative viscosity, plasma viscosity, hematocrit (Hct), erythrocyte sedimentation rate (ESR), and electrophoresis time of erythrocytes were significantly increased in the DIC+saline group compared to the control group. The electrophoretic length and migration of erythrocytes from the DIC+saline and DIC+lymph groups were significantly slower than the control group. Blood relative viscosity, Hct, ESR, and electrophoretic time of erythrocytes were significantly increased in the DIC+lymph group compared to the control group. Whole blood viscosity, relative viscosity and reduced viscosity were significantly lower in the DIC+lymph group than in the DIC+saline group, and erythrocyte deformability index was also significantly higher than in the DIC+saline and control groups. These results suggest that exogenous normal lymph could markedly improve the acute microcirculation disturbance and the abnormal hemorheological properties in rats with DIC induced by Dextran 500

  6. [Perioperative changes of coagulation functions in the local advanced liver cancer patients receiving liver transplantation].

    Science.gov (United States)

    Wang, Hao-Yuan; Zhao, Qing-Yu; Yuan, Yun-Fei

    2008-07-01

    Liver transplantation is widely accepted as an effective therapy of hepatoma. Perioperative dynamic observation of coagulation function is important for graft-receivers. This study was to explore perioperative changes of coagulation functions in the local advanced liver cancer patients who received liver transplantation. Clinical data of 31 local advanced liver cancer patients, underwent liver transplantation from Sep. 2003 to Jan. 2007, were analyzed. Platelet (PLT) counting, prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen (Fib) and international normalized ratio (INR) before operation, at anhepatic phase and the first week after operation were analyzed to evaluate congulation function. The coagulation functions of most patients were normal before operation. The six parameters varied significantly at anhepatic phase and on most days of the first week after operation when compared with the preoperative levels (Pfunctions of local advanced liver cancer patients shift from hypocoagulatory to hypercoagulatory or normal in perioperative period, therefore, prevention of bleeding should be focused on at anhepatic phase and on 1-2 days after operation while prevention of thrombosis should be focused on after the first week after operation. The degree of liver cirrhosis and Child-Pugh level could help to evaluate postoperative coagulation disorder.

  7. Photoacoustic discrimination of viable and thermally coagulated blood using a two-wavelength method for burn injury monitoring

    International Nuclear Information System (INIS)

    Talbert, Robert J; Holan, Scott H; Viator, John A

    2007-01-01

    Discriminating viable from thermally coagulated blood in a burn wound can be used to profile burn depth, thus aiding the removal of necrotic tissue. In this study, we used a two-wavelength photoacoustic imaging method to discriminate coagulated and non-coagulated blood in a dermal burn phantom. Differences in the optical absorption spectra of coagulated and non-coagulated blood produce different values of the ratio of peak photoacoustic amplitude at 543 and 633 nm. The absorption values obtained from spectroscopic measurements indicate that the ratio of photoacoustic pressure for 543 and 633 nm for non-coagulated blood was 15.7:1 and 1.6:1 for coagulated blood. Using planar blood layers, we found the photoacoustic ratios to be 13.5:1 and 1.6:1, respectively. Using the differences in the ratios of coagulated and non-coagulated blood, we propose a scheme using statistical classification analysis to identify the different blood samples. Based upon these distinctly different ratios, we identified the planar blood samples with an error rate of 0%. Using a burn phantom with cylindrical vessels containing coagulated and non-coagulated blood, we achieved an error rate of 11.4%. These results have shown that photoacoustic imaging could prove to be a valuable tool in the diagnosis of burns

  8. COAGULATION PROFILE IN DIABETES MELLITUS AND ITS ASSOCIATION WITH MICROVASCULAR COMPLICATIONS

    Directory of Open Access Journals (Sweden)

    Uma Shankar Mishra

    2017-12-01

    Full Text Available BACKGROUND This study intends to assess the changes in the simple routine coagulation parameters in diabetes mellitus and to investigate whether any relationship exists among changes in these coagulation parameters and development of microvascular complication in diabetes mellitus. MATERIALS AND METHODS Period of study was from 2010-2012. It was done in M.K.C.G. Medical College with the approval from Berhampur University. It is a case control study. 50 diabetic patients and 50 age and sex matched non-diabetic patients were randomly selected. Simple coagulation parameters like Activated Partial Thromboplastin Time (aPTT, Prothrombin Time (PT, serum fibrinogen, platelet count and Plasminogen Activator Inhibitor-1 (PAI-1 were measured. Statistical study was done using unpaired t-test and analysis and calculations were done using GraphPad software. RESULTS Serum fibrinogen was found to be increased in diabetic patients when compared to non-diabetic patients (mean 278 ± 26.9 v/s 232.52 ± 16.5, P value - 0.009, significant. PAI-1 levels was found to be higher among the diabetics when compared to nondiabetics (47.64 ± 8.82 v/s 31.06 ± 7.12, the two-tailed P value is <0.0001, considered extremely significant. Platelet count through within normal limits. It was found to be decreased in diabetic patient when compared to non-diabetic (2.25 ± 0.18 v/s 2.33 ± 0.03, P value - 0.022. Prothrombin Time (PT (13.15 ± 0.52 v/s 13.04 ± 0.49, P value - 0.28 and PTT (33.04 ± 1.31 v/s 32.99 ± 1.29, P value 0.85, found to be statistically insignificant. Among 50 diabetic patients, 24 had neuropathy, 20 had nephropathy, 10 had retinopathy and 21 had none of these complications. On comparing diabetic patients with microvascular complications and without microvascular complications, significant age difference was observed (59.55 ± 5.06 v/s 51.00 ± 3.31, P=0.003. This probably was a reflection of increase in microvascular complications with increasing duration

  9. Nanoparticles and the blood coagulation system. Part I: benefits of nanotechnology.

    Science.gov (United States)

    Ilinskaya, Anna N; Dobrovolskaia, Marina A

    2013-05-01

    Nanotechnology is proven to provide certain benefits in drug delivery by improving solubility, increasing uptake to target sites and changing pharmacokinetics profiles of traditional drugs. Since properties of many materials change tremendously at the nanoscale levels, nanotechnology is also being explored in various industrial applications. As such, nanoparticles are rapidly entering various areas of industry, biology and medicine. The benefits of using nanotechnology for industrial and biomedical applications are often tempered by concerns about the safety of these new materials. One such area of concern includes their effect on the immune system. While nanoparticle interactions with various constituents of the immune system have been reviewed before, little attention was given to nanoparticle effects on the blood coagulation system. Nanoparticle interface with the blood coagulation system may lead to either benefits to the host or adverse reactions. This article reviews recent advances in our understanding of nanoparticle interactions with plasma coagulation factors, platelets, endothelial cells and leukocytes. Part I is focused on desirable interactions between nanoparticles and the coagulation system, and discusses benefits of using nanotechnology to intervene in coagulation disorders. Undesirable interactions posing safety concerns are covered in part II, which will be published in the June issue of Nanomedicine.

  10. The use of cold coagulation for the treatment of cervical intraepithelial neoplasia

    LENUS (Irish Health Repository)

    Wyse, A

    2017-05-01

    In 2015, Cold Coagulation was introduced as a treatment for cervical intraepithelial neoplasia (CIN) at our colposcopy clinic. We reviewed the 6-month follow up data of the first 200 women who underwent Cold Coagulation using cytology and HPV status as tests of cure (TOC). A random sample of 200 patients treated by Large Loop Excision of the Transformation Zone (LLETZ) during the same period was used to compare treatment outcome. Six months following treatment,173 (86.5%) of the women treated by CC and 167 (83.5%) treated by LLETZ had negative cytology. (x2= P>0.05). 148 (74%) treated by Cold Coagulation and 166 (83%) treated by LLETZ were HPV negative (x2= P<0.05). One hundred and thirty-nine (70%) women treated by Cold Coagulation and 152 (76%) treated with LLETZ had normal cytology and were HPV negative. This audit of our initial experience supports the observation that Cold Coagulation is as effective as LLETZ in the management of CIN when cervical cytology is used as a test of cure.

  11. Quantitative proteome profiling of normal human circulating microparticles

    DEFF Research Database (Denmark)

    Østergaard, Ole; Nielsen, Christoffer T; Iversen, Line V

    2012-01-01

    Circulating microparticles (MPs) are produced as part of normal physiology. Their numbers, origin, and composition change in pathology. Despite this, the normal MP proteome has not yet been characterized with standardized high-resolution methods. We here quantitatively profile the normal MP...... proteome using nano-LC-MS/MS on an LTQ-Orbitrap with optimized sample collection, preparation, and analysis of 12 different normal samples. Analytical and procedural variation were estimated in triply processed samples analyzed in triplicate from two different donors. Label-free quantitation was validated...... by the correlation of cytoskeletal protein intensities with MP numbers obtained by flow cytometry. Finally, the validity of using pooled samples was evaluated using overlap protein identification numbers and multivariate data analysis. Using conservative parameters, 536 different unique proteins were quantitated...

  12. Chronic sleep deprivation markedly reduces coagulation factor VII expression

    Science.gov (United States)

    Pinotti, Mirko; Bertolucci, Cristiano; Frigato, Elena; Branchini, Alessio; Cavallari, Nicola; Baba, Kenkichi; Contreras-Alcantara, Susana; Ehlen, J. Christopher; Bernardi, Francesco; Paul, Ketema N.; Tosini, Gianluca

    2010-01-01

    Chronic sleep loss, a common feature of human life in industrialized countries, is associated to cardiovascular disorders. Variations in functional parameters of coagulation might contribute to explain this relationship. By exploiting the mouse model and a specifically designed protocol, we demonstrated that seven days of partial sleep deprivation significantly decreases (−30.5%) the thrombin generation potential in plasma evaluated upon extrinsic (TF/FVIIa pathway) but not intrinsic activation of coagulation. This variation was consistent with a decrease (−49.8%) in the plasma activity levels of factor VII (FVII), the crucial physiologicalal trigger of coagulation, which was even more pronounced at the liver mRNA level (−85.7%). The recovery in normal sleep conditions for three days completely restored thrombin generation and FVII activity in plasma. For the first time, we demonstrate that chronic sleep deprivation on its own reduces, in a reversible manner, the FVII expression levels, thus influencing the TF/FVIIa activation pathway efficiency. PMID:20418241

  13. The coagulation factor Xa/protease activated receptor-2 axis in the progression of liver fibrosis : a multifaceted paradigm

    NARCIS (Netherlands)

    Borensztajn, Keren; von der Thusen, Jan H.; Peppelenbosch, Maikel P.; Spek, C. Arnold

    2010-01-01

    Introduction Activation of the coagulation cascade during liver fibrosis: a puzzling paradox Protease-activated receptors: the link between coagulation cascade activation and liver fibrosis Expression and distribution of human PAR-2 in normal and pathological liver tissue FXa signalling on PAR-2

  14. Relative effects of plasma, fibrinogen concentrate, and factor XIII on ROTEM coagulation profiles in an in vitro model of massive transfusion in trauma.

    Science.gov (United States)

    Schmidt, David E; Halmin, Märit; Wikman, Agneta; Östlund, Anders; Ågren, Anna

    2017-10-01

    Massive traumatic haemorrhage is aggravated through the development of trauma-induced coagulopathy, which is managed by plasma transfusion and/or fibrinogen concentrate administration. It is yet unclear whether these treatments are equally potent in ensuring adequate haemostasis, and whether additional factor XIII (FXIII) administration provides further benefits. In this study, we compared ROTEM whole blood coagulation profiles after experimental massive transfusion with different transfusion regimens in an in vitro model of dilution- and transfusion-related coagulopathy. Healthy donor blood was mixed 1 + 1 with six different transfusion regimens. Each regimen contained RBC, platelet concentrate, and either fresh frozen plasma (FFP) or Ringer's acetate (RA). The regimens were further augmented through addition of a low- or medium-dose fibrinogen concentrate and FXIII. Transfusion with FFP alone was insufficient to maintain tissue-factor activated clot strength, coincidental with a deficiency in fibrin-based clot strength. Fibrinogen concentrate conserved, but did not improve coagulation kinetics and overall clot strength. Only combination therapy with FFP and low-dose fibrinogen concentrate improved both coagulation kinetics and fibrin-based clot strength. Administration of FXIII did not result in an improvement of clot strength. In conclusion, combination therapy with both FFP and low-dose fibrinogen concentrate improved clotting time and produced firm clots, representing a possible preferred first-line regimen to manage trauma-induced coagulopathy when RBC and platelets are also transfused. Further research is required to identify optimal first-line transfusion fluids for massive traumatic haemorrhage.

  15. TRAITEMENT DES EAUX USEES PAR COAGULATION-FLOCULATION EN UTILISANT LE SULFATE D’ALUMINIUM COMME COAGULANT

    OpenAIRE

    Nora SEGHAIRI; Leila MIMECHE; Adel BOUZID; Yassir AYACHI

    2017-01-01

    Domestic wastewater treatment by coagulation-flocculation is widely used internationally. This treatment reduces color and turbidity, indicating organic and inorganic contaminants, but at acceptable levels for treated waste water discharged into the receiving environment. The objective of this study is to optimize the treatment of wastewater by coagulation-flocculation using aluminum sulphate as a coagulant. Various reaction parameters are taken into account, such as the coagulant dose,...

  16. Blood coagulation factors as inflammatory mediators

    NARCIS (Netherlands)

    Schoenmakers, Saskia H. H. F.; Reitsma, Pieter H.; Spek, C. Arnold

    2005-01-01

    After the first observations about blood coagulation by Hippocrates, it took until the early 1900s before the classic theory of blood coagulation was presented. As more and more other coagulation factors were discovered, the four-factor coagulation scheme became more complex, but better understood,

  17. COAGULATION ACTIVITY IN LIVER DISEASE

    Directory of Open Access Journals (Sweden)

    Dr. Sheikh Sajjadieh Mohammad Reza

    2009-07-01

    Full Text Available Patients with advanced hepatic failure may present with the entire spectrum of coagulation factor deficiencies. This study was designed to determine laboratory abnormalities in coagulation in chronic liver disease and the association of these abnormalities with the extent of chronic hepatitis and cirrhosis. Coagulation markers were assayed in 60 participants: 20 patients with chronic hepatitis, 20 patients with cirrhosis, and 20 healthy individuals (control. Plasma levels of anti-thrombin III were determined by a chromogenic substrate method, and plasma concentrations of fibrinogen were analyzed by the Rutberg method. Commercially available assays were used for laboratory coagulation tests. The levels of coagualation activity markers in patients with chronic liver disease were significantly different in comparison to those in healthy participants. These results indicate the utility of measuring markers for coagulation activity in determining which cirrhosis patients are more susceptible to disseminated intravascular coagulation.

  18. Coagulation performance of a novel poly-ferric-acetate (PFC) coagulant in phosphate-kaolin synthetic water treatment

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Yanxin; Lu, Jinpeng; Dong, Xiongzi; Yao, Chengli [Hefei Normal University, Hefei (China); Hao, Jianwen [Anhui Vocational and Technical College, Hefei (China)

    2017-10-15

    The process of coagulation-flocculation is increasingly applied in wastewater treatment. And the polymerized inorganic coagulants are widely used among these coagulation-flocculation processes. However, conventional coagulants using sulfates or chlorides as counter anion may give rise to corrosion. The purpose of this study was to synthesize PFC coagulants in which acetate is used as counter anion. The influences on the preparation of PFC were optimized. The synthesis was done at the optimum conditions, such as temperature of 60 .deg. C, the Fe/CH{sub 3}COOH molar ratio of 1 : 4.0 and reaction time of 6 h, respectively. The prepared PFC coagulants were characterized by Fourier transform infrared (FTIR) spectrophotometry and scanning electron microscopy (SEM). PFC was found to mainly form complexation polymeric species and present more cluster and lamellar structure. A series of jar tests were carried out to study the coagulation performance of PFC and PFS in phosphate-kaolin synthetic water treatment. Results showed that the coagulation performance of PFC was more efficient than PFS's in terms of the phosphorus removal efficiency and the residual turbidity. Due to using acetate as counter anion to iron, PFC is less harmful to the processes of water treatment and equipment than that of the conventional coagulants applied chlorides or sulfates. Therefore, PFC is a promising coagulant in the process of corrosion sensitive applications and the process of wastewater containing phosphorus treatment.

  19. Effect of Centrifuge Temperature on Routine Coagulation Tests.

    Science.gov (United States)

    Yazar, Hayrullah; Özdemir, Fatma; Köse, Elif

    2018-01-01

    This study investigated the effects of cooled and standard centrifuges on the results of coagulation tests to examine the effects of centrifugation temperature. Equal-volume blood samples from each patient were collected at the same time intervals and subjected to standard (25°C) and cooled centrifugation (2-4°C). Subsequently, the prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (aPTT), fibrinogen, and D-dimer values were determined in runs with the same lot numbers in the same coagulation device using the Dia-PT R (PT and INR), Dia-PTT-liquid (aPTT), Dia-FIB (fibrinogen), and Dia-D-dimer kits, respectively. The study enrolled 771 participants. The PT was significantly (p centrifuges were as follows: PT 10.30 versus 10.50 s; PT (INR) 1.04 versus 1.09 s; APTT 28.90 versus 29.40 s; fibrinogen 321.5 versus 322.1 mg/dL; and D-dimer 179.5 versus 168.7 µg FEU/mL. There were significant differences (p centrifuges. Centrifuge temperature can have a significant effect on the results of coagulation tests. However, broad and specific disease-based studies are needed. © 2018 S. Karger AG, Basel.

  20. Preliminary assessment of the importance of turbulent coagulation in the Kuwaiti oil fires. Final report, April 1992-June 1993

    Energy Technology Data Exchange (ETDEWEB)

    Kohlberg, I.

    1993-06-01

    This study provides a mathematical determination of the spatial distribution of aerosols due to turbulent shear coagulation and turbulent inertial coagulation, as applied to the conditions of the Kuwaiti Oil Fires (KOF) of 1991. Using an approximation from a forest fire for the normalized size distribution of aerosols, the downstream particle concentration is found by the concurrent solution of the coagulations' kinetics combined with turbulent atmospheric diffusion. The result shows the explicit dependence of the concentration on the following principal parameters: turbulent energy dissipation rate, turbulent diffusion constant, average wind speed, mass ejection from a well, Kolmorogov time scale for turbulence, and Kolmorogov length scale for turbulence. For very large values of turbulent energy dissipation rate, turbulent inertial coagulation is more effective than turbulent shear coagulation in particle growth. The spatial dependence of concentration attributed to turbulent coagulation may vary considerably. Depending on the choice of parameters, the importance of turbulent coagulation in particle transport processes may extend from less than a kilometer to tens of kilometers. Kuwaiti Oil Fires (KOF), Particle transport, Turbulent inertial coagulation, Turbulent shear coagulation.

  1. Removal of Dye in Wastewater by Adsorption-Coagulation Combined System with Hibiscus sabdariffa as the Coagulant

    Directory of Open Access Journals (Sweden)

    Hoong Ho Nicholas Jian

    2018-01-01

    Full Text Available The conventional process to treat dye wastewater is the physicochemical treatment such as coagulation, flocculation and adsorption process. A new approach has been demonstrated to treat Congo red dye wastewater, which is the adsorption-coagulation hybrid process. Natural coagulant extracted from Hibiscus sabdariffa seeds is used as the coagulant while activated carbon is used as the adsorbent in this case study. The objective of this experiment is to study the significant factors that will affect the efficiency of dye removal. Then, the optimum conditions for the hybrid process is determined using Respond Surface Methodology (RSM. The variables are pH, initial dye concentration, coagulant dosage and adsorbent dosage while the response of experiment is the dye removal percentage. A three-level and four-variable Box-Behnken design (BBD is used for the RSM. A total of 27 sets of experimental results is required to determine the optimum conditions. Jar test is used to conduct the experiment with the addition of coagulant and adsorbent simultaneously. Based on the regression model analysis and ANOVA, the highly significant factors that contribute to the dye removal efficiency through adsorption-coagulation hybrid process are pH of solution and initial dye concentration. The RSM results shows that the optimised process parameters for adsorption-coagulation hybrid process with Hibiscus sabdariffa seeds as the coagulant and activated carbon as the adsorbent are pH 2, initial dye concentration of 385 ppm, coagulant dosage of 209 mg/L and adsorbent dosage of 150 mg/L. The dye removal reaches up to 96.67% under optimum parameters.

  2. The investigation of coagulation activity of natural coagulants extracted from different strains of common bean

    Directory of Open Access Journals (Sweden)

    Šćiban Marina B.

    2010-01-01

    Full Text Available Coagulation and flocculation by adding chemicals are the methods that are usually used for removal of water turbidity. This study is concerned with the coagulation activity of extracts of various strains of bean. The aim was to ascertain if bean varieties influence coagulation activity. Active components were extracted from 1 g of ground sample with 100 ml distilled water. Contents of dry matter and nitrogen were specified in the solid samples, and the content of soluble nitrogen was determined in the extracts. These data were used to calculate the efficiency of extraction of nitrogen-containing compounds. The coagulation activity was assessed by jar test using synthetic turbid water, of the initial pH 9 and turbidity 35 NTU. The jar test was carried out by adding different amounts of extracts to model water, and stirring the content. After sedimentation for 1 h, residual turbidity was determined by turbidimeter and coagulation activity was calculated. The increment of organic matter concentration after the coagulation was also determined. These experiments confirmed that extracts of all investigated strains of bean could be used successfully as natural coagulants.

  3. Normal range values for thromboelastography in healthy adult volunteers

    Directory of Open Access Journals (Sweden)

    S. Scarpelini

    2009-12-01

    Full Text Available Thromboelastography (TEG® provides a functional evaluation of coagulation. It has characteristics of an ideal coagulation test for trauma, but is not frequently used, partially due to lack of both standardized techniques and normal values. We determined normal values for our population, compared them to those of the manufacturer and evaluated the effect of gender, age, blood type, and ethnicity. The technique was standardized using citrated blood, kaolin and was performed on a Haemoscope 5000 device. Volunteers were interviewed and excluded if pregnant, on anticoagulants or having a bleeding disorder. The TEG® parameters analyzed were R, K, α, MA, LY30, and coagulation index. All volunteers outside the manufacturer’s normal range underwent extensive coagulation investigations. Reference ranges for 95% for 118 healthy volunteers were R: 3.8-9.8 min, K: 0.7-3.4 min, α: 47.8-77.7 degrees, MA: 49.7-72.7 mm, LY30: -2.3-5.77%, coagulation index: -5.1-3.6. Most values were significantly different from those of the manufacturer, which would have diagnosed coagulopathy in 10 volunteers, for whom additional investigation revealed no disease (81% specificity. Healthy women were significantly more hypercoagulable than men. Aging was not associated with hypercoagulability and East Asian ethnicity was not with hypocoagulability. In our population, the manufacturer’s normal values for citrated blood-kaolin had a specificity of 81% and would incorrectly identify 8.5% of the healthy volunteers as coagulopathic. This study supports the manufacturer’s recommendation that each institution should determine its own normal values before adopting TEG®, a procedure which may be impractical. Consideration should be given to a multi-institutional study to establish wide standard values for TEG®.

  4. Evaluation of the process of coagulation/flocculation of produced water using Moringa oleifera Lam. as natural coagulant

    Energy Technology Data Exchange (ETDEWEB)

    Santana, C.R.; Pereira, D.F.; Sousa, S.C S N.; Silva, G.F. [Universidade Federal de Sergipe (UFSE), Sao Cristovao, SE (Brazil). Dept. de Engenharia Quimica], e-mail: claudia@ufs.br; Cavalcanti, E.B. [Universidade Tiradentes (UNIT), SE (Brazil). Inst. de Tecnologia e Pesquisa

    2010-07-15

    In the lifetime of an oil well, there comes a moment when a lot of water begins to be produced along with oil, either by the conditions of the reservoir, or as a result of water injection in the secondary recovery of the well. An important step in such process involves the treatment of the produced water by means of coagulation techniques. Therefore, the use of environmentally correct coagulants is presented as a viable alternative and has demonstrated advantages over the use of chemical coagulants. The plant of the genus Moringa, whose species is oleifera Lam, stands out as one of the most promising natural coagulants. The present study investigated the evaluation of the coagulation/flocculation of produced water, using seeds of Moringa oleifera Lam. as coagulant. The results were very significant, demonstrating that Moringa oleifera Lam. can be used as a natural coagulant in this type of treatment. (author)

  5. Enhanced coagulation for improving coagulation performance and reducing residual aluminum combining polyaluminum chloride with diatomite.

    Science.gov (United States)

    Hu, Wenchao; Wu, Chunde

    2016-01-01

    The feasibility of using enhanced coagulation, which combined polyaluminum chloride (PAC) with diatomite for improving coagulation performance and reducing the residual aluminum (Al), was discussed. The effects of PAC and diatomite dosage on the coagulation performance and residual Al were mainly investigated. Results demonstrated that the removal efficiencies of turbidity, dissolved organic carbon (DOC), and UV254 were significantly improved by the enhanced coagulation, compared with PAC coagulation alone. Meaningfully, the five forms of residual Al (total Al (TAl), total dissolved Al (TDAl), dissolved organic Al (DOAl), dissolved monomeric Al (DMAl), and dissolved organic monomeric Al (DOMAl)) all had different degrees of reduction in the presence of diatomite and achieved the lowest concentrations (0.185, 0.06, 0.053, 0.014, and 0 mg L(-1), respectively) at a PAC dose of 15 mg L(-1) and diatomite dose of 40 mg L(-1). In addition, when PAC was used as coagulant, the majority of residual Al existed in dissolved form (about 31.14-70.16%), and the content of DOMAl was small in the DMAl.

  6. Theories of blood coagulation.

    Science.gov (United States)

    Riddel, James P; Aouizerat, Bradley E; Miaskowski, Christine; Lillicrap, David P

    2007-01-01

    Although the concept of the coagulation cascade represented a significant advance in the understanding of coagulation and served for many years as a useful model, more recent clinical and experimental observations demonstrate that the cascade/waterfall hypothesis does not fully and completely reflect the events of hemostasis in vivo. The goal of this article is to review the evolution of the theories of coagulation and their proposed models to serve as a tool when reviewing the research and practice literature that was published in the context of these different theories over time.

  7. An assessment of the utility of unselected coagulation screening in general hospital practice.

    LENUS (Irish Health Repository)

    McHugh, Johnny

    2011-03-01

    Coagulation screening using prothrombin time (PT) and activated partial thromboplastin time (APTT) is widely used. We performed an audit of coagulation screening in an Irish teaching hospital. We analysed PT and\\/or APTT results received during normal working hours during a 1-week period in our hospital. Abnormal results due to anticoagulants were excluded from further study. In samples with PT longer than 15.5 s and\\/or APTT longer than 42 s, we proceeded to 1: 1 mixing studies if the PT was prolonged and 1: 1 mixing studies, factor XII assay and lupus screen if the APTT was prolonged. We also obtained referral source for all samples and clinical details for abnormal samples. Six hundred and seventy-one coagulation requests were received during the study period. Three hundred and eighteen of 671 (47.4%) coagulation requests were for monitoring of anticoagulation. Three hundred and fifty-three of 671 (52.6%) requests were for coagulation screening rather than anticoagulant monitoring. In the coagulation screens received, PT was prolonged in 19 of 353 (5.4%). PT was longer than 20 s in four of 353 cases (1.1%). APTT was prolonged in 19 of 353 (5.4%). APTT was longer than 50 s in four of 353 (1.1%). No patients with abnormal PT or APTT had any bleeding sequelae during the study period. Unregulated coagulation screening has a low yield of abnormal results; the majority of these abnormal results show mild prolongation of PT or APTT with no evidence that they are associated with an increased bleeding risk.

  8. Variation-preserving normalization unveils blind spots in gene expression profiling

    Science.gov (United States)

    Roca, Carlos P.; Gomes, Susana I. L.; Amorim, Mónica J. B.; Scott-Fordsmand, Janeck J.

    2017-01-01

    RNA-Seq and gene expression microarrays provide comprehensive profiles of gene activity, but lack of reproducibility has hindered their application. A key challenge in the data analysis is the normalization of gene expression levels, which is currently performed following the implicit assumption that most genes are not differentially expressed. Here, we present a mathematical approach to normalization that makes no assumption of this sort. We have found that variation in gene expression is much larger than currently believed, and that it can be measured with available assays. Our results also explain, at least partially, the reproducibility problems encountered in transcriptomics studies. We expect that this improvement in detection will help efforts to realize the full potential of gene expression profiling, especially in analyses of cellular processes involving complex modulations of gene expression. PMID:28276435

  9. Enhanced algae removal by Ti-based coagulant: comparison with conventional Al- and Fe-based coagulants.

    Science.gov (United States)

    Xu, Jie; Zhao, Yanxia; Gao, Baoyu; Zhao, Qian

    2018-05-01

    The water eutrophication caused by cyanobacteria seasonally proliferates, which is a hot potato to be resolved for water treatment plants. This study firstly investigated coagulation performance of titanium tetrachloride (TiCl 4 ) for Microcystis aeruginosa synthetic water treatment. Results show complete algal cell removal by TiCl 4 coagulation without damage to cell membrane integrity even under harsh conditions; 60 mg/L TiCl 4 was effective in removing the microcystins up to 85%. Furthermore, besides having stronger UV 254 removal capability and the higher removal of fluorescent substances over Al- and Fe-based coagulants, TiCl 4 coagulant required more compact coagulation and sedimentation tanks due to its significantly improved floc growth and sedimentation speed. Meanwhile, its' short hydraulic retention time avoided algal cell breakage and subsequent algal organic matter release. Microcystin concentrations were kept at a low level during sludge storage period, indicating that the TiCl 4 flocs could prevent algal cells from natural lysis. To facilitate water recycling without secondary contamination, the algae-containing sludge after TiCl 4 coagulation ought to be disposed within 12 days at 20 °C and 8 days at 35 °C.

  10. The interplay between platelets and coagulation

    NARCIS (Netherlands)

    Weeterings, C.

    2009-01-01

    Platelet activation and blood coagulation are two processes often studied separately, but which cannot be seen independently from each other. Platelets play a pivotal role in coagulation, not only by providing negatively charged phospholipids, but also in localizing the coagulation process from a

  11. Impaired plasma lipid profiles in acute hepatitis

    Directory of Open Access Journals (Sweden)

    Wang Yongzhong

    2010-01-01

    Full Text Available Abstract The present study examined plasma lipid profiles in thirty patients suffered from acute viral hepatitis. Patients' blood samples were collected at both the debut and recovery of diseases. Thirty sex and age matched normal subjects were included as controls. Plasma total triglycerides (TG, total cholesterol, high density lipoprotein cholesterol (HDL-C, low density lipoprotein cholesterol (LDL-C, apolipoprotein AI (ApoAI, apolipoprotein B (ApoB, lipoprotein (a (Lp(a, blood coagulation status including prothrombin complex activity and activated partial tromboplastin time (APTT, and hepatic functions were determined by the automatic biochemical analytical instrument. It demonstrated that plasma levels of total cholesterol, HDL-C and apoAI were significantly lower in the patients at the acute phase of hepatitis than those in normal subjects, whereas plasma levels of TG and LDL-C were obviously higher in the patients than in normal subjects (P

  12. Dust coagulation in ISM

    Science.gov (United States)

    Chokshi, Arati; Tielens, Alexander G. G. M.; Hollenbach, David

    1989-01-01

    Coagulation is an important mechanism in the growth of interstellar and interplanetary dust particles. The microphysics of the coagulation process was theoretically analyzed as a function of the physical properties of the coagulating grains, i.e., their size, relative velocities, temperature, elastic properties, and the van der Waal interaction. Numerical calculations of collisions between linear chains provide the wave energy in individual particles and the spectrum of the mechanical vibrations set up in colliding particles. Sticking probabilities are then calculated using simple estimates for elastic deformation energies and for the attenuation of the wave energy due to absorption and scattering processes.

  13. Comparison of serum lipid profiles between normal controls and breast cancer patients

    Directory of Open Access Journals (Sweden)

    Pikul Laisupasin

    2013-01-01

    Full Text Available Background: Researchers have reported association of plasma/serum lipids and lipoproteins with different cancers. Increase levels of circulating lipids and lipoproteins have been associated with breast cancer risk. Aim: The aim of this study is to compare serum lipid profiles: total-cholesterol (T-CHOL, triglyceride (TG, high density lipoprotein-cholesterol (HDL-C, low density lipoprotein-cholesterol (LDL-C and very low density lipoprotein-cholesterol (VLDL-C between breast cancer patients and normal participants. Materials and Methods: A total of 403 women in this study were divided into two groups in the period during May 2006-April 2007. Blood samples were collected from 249 patients with early stage breast cancer and 154 normal controls for serum lipid profiles (T-CHOL, TG, HDL-C, LDL-C and VLDL-C analysis using Hitachi 717 Autoanalyzer (Roche Diagnostic GmbH, Germany. TG, LDL-C and VLDL-C levels in breast cancer group were significantly increased as compared with normal controls group (P < 0.001, whereas HDL-C and T-CHOL levels were not. Results: The results of this study suggest that increased serum lipid profiles may associate with breast cancer risk in Thai women. Further studies to group important factors including, cancer stages, types of cancer, parity, and menopausal status that may affect to lipid profiles in breast cancer patients along with an investigation of new lipid profiles to clarify most lipid factors that may involve in breast cancer development are needed.

  14. Removal Natural Organic Matter (NOM in Peat Water from Wetland Area by Coagulation-Ultrafiltration Hybrid Process with Pretreatment Two-Stage Coagulation

    Directory of Open Access Journals (Sweden)

    Mahmud Mahmud

    2016-06-01

    Full Text Available The primary problem encountered in the application of membrane technology was membrane fouling. During this time, hybrid process by coagulation-ultrafiltration in drinking water treatment that has been conducted by some research, using by one-stage coagulation. The goal of this research was to investigate the effect of two-stage coagulation as a pretreatment towards performance of the coagulation-ultrafiltration hybrid process for removal NOM in the peat water. Coagulation process, either with the one-stage or two-stage coagulation was very good in removing charge hydrophilic fraction, i.e. more than 98%. NOM fractions of the peat water, from the most easily removed by the two-stage coagulation and one-stage coagulation process was charged hydrophilic>strongly hydrophobic>weakly hydrophobic>neutral hydrophilic. The two-stage coagulation process could removed UV254 and colors with a little better than the one-stage coagulation at the optimum coagulant dose. Neutral hydrophilic fraction of peat water NOM was the most influential fraction of UF membrane fouling. The two-stage coagulation process better in removing the neutral hidrophilic fraction, while removing of the charged hydrophilic, strongly hydrophobic and weakly hydrophobic similar to the one-stage coagulation. Hybrid process by pretreatment with two-stage coagulation, beside can increased removal efficiency of UV254 and color, also can reduced fouling rate of the ultrafiltration membraneIt must not exceed 250 words, contains a brief summary of the text, covering the whole manuscript without being too elaborate on every section. Avoid any abbreviation, unless it is a common knowledge or has been previously stated.

  15. Removal Natural Organic Matter (NOM in Peat Water from Wetland Area by Coagulation-Ultrafiltration Hybrid Process with Pretreatment Two-Stage Coagulation

    Directory of Open Access Journals (Sweden)

    Mahmud Mahmud

    2013-11-01

    Full Text Available The primary problem encountered in the application of membrane technology was membrane fouling. During this time, hybrid process by coagulation-ultrafiltration in drinking water treatment that has been conducted by some research, using by one-stage coagulation. The goal of this research was to investigate the effect of two-stage coagulation as a pretreatment towards performance of the coagulation-ultrafiltration hybrid process for removal NOM in the peat water. Coagulation process, either with the one-stage or two-stage coagulation was very good in removing charge hydrophilic fraction, i.e. more than 98%. NOM fractions of the peat water, from the most easily removed by the two-stage coagulation and one-stage coagulation process was charged hydrophilic>strongly hydrophobic>weakly hydrophobic>neutral hydrophilic. The two-stage coagulation process could removed UV254 and colors with a little better than the one-stage coagulation at the optimum coagulant dose. Neutral hydrophilic fraction of peat water NOM was the most influential fraction of UF membrane fouling. The two-stage coagulation process better in removing the neutral hidrophilic fraction, while removing of the charged hydrophilic, strongly hydrophobic and weakly hydrophobic similar to the one-stage coagulation. Hybrid process by pretreatment with two-stage coagulation, beside can increased removal efficiency of UV254 and color, also can reduced fouling rate of the ultrafiltration membraneIt must not exceed 250 words, contains a brief summary of the text, covering the whole manuscript without being too elaborate on every section. Avoid any abbreviation, unless it is a common knowledge or has been previously stated.

  16. A PK-PD model-based assessment of sugammadex effects on coagulation parameters.

    Science.gov (United States)

    Bosch, Rolien; van Lierop, Marie-José; de Kam, Pieter-Jan; Kruithof, Annelieke C; Burggraaf, Jacobus; de Greef, Rik; Visser, Sandra A G; Johnson-Levonas, Amy O; Kleijn, Huub-Jan

    2016-03-10

    Exposure-response analyses of sugammadex on activated partial thromboplastin time (APTT) and prothrombin time international normalized ratio (PT(INR)) were performed using data from two clinical trials in which subjects were co-treated with anti-coagulants, providing a framework to predict these responses in surgical patients on thromboprophylactic doses of low molecular weight or unfractionated heparin. Sugammadex-mediated increases in APTT and PT(INR) were described with a direct effect model, and this relationship was similar in the presence or absence of anti-coagulant therapy in either healthy volunteers or surgical patients. In surgical patients on thromboprophylactic therapy, model-based predictions showed 13.1% and 22.3% increases in respectively APTT and PT(INR) within 30min after administration of 16mg/kg sugammadex. These increases remain below thresholds seen following treatment with standard anti-coagulant therapy and were predicted to be short-lived paralleling the rapid decline in sugammadex plasma concentrations. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Diurnal glycemic profile in obese and normal weight nondiabetic pregnant women.

    Science.gov (United States)

    Yogev, Yariv; Ben-Haroush, Avi; Chen, Rony; Rosenn, Barak; Hod, Moshe; Langer, Oded

    2004-09-01

    A paucity of data exists concerning the normal glycemic profile in nondiabetic pregnancies. Using a novel approach that provides continuous measurement of blood glucose, we sought to evaluate the ambulatory daily glycemic profile in the second half of pregnancy in nondiabetic women. Fifty-seven obese and normal weight nondiabetic subjects were evaluated for 72 consecutive hours with continuous glucose monitoring by measurement interstitial glucose levels in subcutaneous tissue every 5 minutes. Subjects were instructed not to modify their lifestyle or to follow any dietary restriction. For each woman, mean and fasting blood glucose values were determined; for each meal during the study period, the first 180 minutes were analyzed. For the study group, the fasting blood glucose level was 75 +/- 12 mg/dL; the mean blood glucose level was 83.7 +/- 18 mg/dL; the postprandial peak glucose value level was 110 +/- 16 mg/dL, and the time interval that was needed to reach peak postprandial glucose level was 70 +/- 13 minutes. A similar postprandial glycemic profile was obtained for breakfast, lunch, and dinner. Obese women were characterized by a significantly higher postprandial glucose peak value, increased 1- and 2-hour postprandial glucose levels, increased time interval for glucose peak, and significantly lower mean blood glucose during the night. No difference was found in fasting and mean blood glucose between obese and nonobese subjects. Glycemic profile characterization in both obese and normal weight nondiabetic subjects provide a measure for the desired level of glycemic control in pregnancy that is complicated with diabetes mellitus.

  18. TRAITEMENT DES EAUX USEES PAR COAGULATION-FLOCULATION EN UTILISANT LE SULFATE D’ALUMINIUM COMME COAGULANT

    Directory of Open Access Journals (Sweden)

    Nora SEGHAIRI

    2017-12-01

    Full Text Available Domestic wastewater treatment by coagulation-flocculation is widely used internationally. This treatment reduces color and turbidity, indicating organic and inorganic contaminants, but at acceptable levels for treated waste water discharged into the receiving environment. The objective of this study is to optimize the treatment of wastewater by coagulation-flocculation using aluminum sulphate as a coagulant. Various reaction parameters are taken into account, such as the coagulant dose, the pH of the solutions, the conductivity, the BOD5, the nitrates, the ammonium and the phosphates. We found from the different results obtained the optimal dose of aluminum sulphate is 400 mg/l with a reduction of 96.31%, 82.44% 90.95% and 78.74% respectively for phosphates, nitrates, ammonium and BOD5. It is recognized that pH influences the abatement rates of pollution contained in wastewater. For each water, there is a pH range for which coagulation- flocculation takes place rapidly. For our study, the optimum pH for removal of BOD5 and ammonium is between 6 and 7.

  19. Microwave tissue coagulation: effects of power and treatment time on coagulation size

    International Nuclear Information System (INIS)

    Kang, Seung Pyung; Kim, Young Hwan; Park, Dong Man; Kim, Jeong Seok; Park, Seo Young; Cha, Soon Joo; Hur, Gham

    1999-01-01

    To determine the effects of power and coagulation time on lesion size of ex-vivo bovine liver using microwaves. Six bovine livers were divided into two groups (first group : 30W output, second group : 60W output) and microwave coagulation was performed for 30, 60, and 120 sec. Thermal injury site was then observed by means of sonography, and the maximal transverse diameter of the echo-change portion after microwave coagulation was measured. On the section of specimen, maximal transverse diameters of the thermal injury site were measured by gross inspection and compared with the result of sonographic measurement. Maximal transverse diameters of hyperechoic lesions of the first group, as seen on sonography, were 8.3mm, 12.2mm, and 15.6mm, and the maximal transverse diameters of thermal injury sites on gross specimens were 9.1mm, 12.0mm, and 15.1mm, respectively. Maximal transverse diameters of hyperechoic lesions of the second group, as seen on sonography, were 12.1mm, 17.4mm, and 21.2mm and maximal transverse diameters of thermal injury sites on gross specimens were 13.2mm, 16.0mm, and 20.0mm, respectively. Statistically maximal transverse diameters of hyperechoic lesions, as seen on sonography, correlated closely with the gross findings of maximal transverse diameters of thermal injury sites (P < .05). Maximal transverse diameters of thermal injury sites were significantly increased as the output of the microwave coagulator and the duration of coagulation time increased (P < .05)

  20. Roentgenographic studies of Korean adults profile with normal occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Park, Tae Won [College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1972-11-15

    A roentgraphic cephalometric study was made on the soft and hard tissue profile of Korean adults. The subject consisted of 52 males and 54 females from 17 to 22 years of age and with normal occlusion and acceptable profile. Twenty one landmarks were plotted and two oriented lines named SnH line and SnV line were drawn on the tracings of all cephalograms. The means and the standard deviations from the subjects were calculated in each measuring category and the means were compared with those of male and female samples. The results were obtained as follow: 1. In depth and height, individual variations and sex differences of the lower facial profile were larger than the upper face. 2. The sex differences of upper facial profile were larger in height than depth. 3. The individual variations and sex differences of the top of nose were the smallest in all measuring points. 4. The thickness of the soft tissue of upper face and upper lip in male sample were larger than those of female, but the same matter were not found in mental region.

  1. Prehospital resuscitation with hypertonic saline-dextran modulates inflammatory, coagulation and endothelial activation marker profiles in severe traumatic brain injured patients

    Directory of Open Access Journals (Sweden)

    Morrison Laurie J

    2010-01-01

    Full Text Available Abstract Background Traumatic brain injury (TBI initiates interrelated inflammatory and coagulation cascades characterized by wide-spread cellular activation, induction of leukocyte and endothelial cell adhesion molecules and release of soluble pro/antiinflammatory cytokines and thrombotic mediators. Resuscitative care is focused on optimizing cerebral perfusion and reducing secondary injury processes. Hypertonic saline is an effective osmotherapeutic agent for the treatment of intracranial hypertension and has immunomodulatory properties that may confer neuroprotection. This study examined the impact of hypertonic fluids on inflammatory/coagulation cascades in isolated head injury. Methods Using a prospective, randomized controlled trial we investigated the impact of prehospital resuscitation of severe TBI (GCS vs 0.9% normal saline (NS, on selected cellular and soluble inflammatory/coagulation markers. Serial blood samples were drawn from 65 patients (30 HSD, 35 NS at the time of hospital admission and at 12, 24, and 48-h post-resuscitation. Flow cytometry was used to analyze leukocyte cell-surface adhesion (CD62L, CD11b and degranulation (CD63, CD66b molecules. Circulating concentrations of soluble (sL- and sE-selectins (sL-, sE-selectins, vascular and intercellular adhesion molecules (sVCAM-1, sICAM-1, pro/antiinflammatory cytokines [tumor necrosis factor (TNF-α and interleukin (IL-10], tissue factor (sTF, thrombomodulin (sTM and D-dimers (D-D were assessed by enzyme immunoassay. Twenty-five healthy subjects were studied as a control group. Results TBI provoked marked alterations in a majority of the inflammatory/coagulation markers assessed in all patients. Relative to control, NS patients showed up to a 2-fold higher surface expression of CD62L, CD11b and CD66b on polymorphonuclear neutrophils (PMNs and monocytes that persisted for 48-h. HSD blunted the expression of these cell-surface activation/adhesion molecules at all time-points to

  2. Emergent self-similarity of cluster coagulation

    Science.gov (United States)

    Pushkin, Dmtiri O.

    A wide variety of nonequilibrium processes, such as coagulation of colloidal particles, aggregation of bacteria into colonies, coalescence of rain drops, bond formation between polymerization sites, and formation of planetesimals, fall under the rubric of cluster coagulation. We predict emergence of self-similar behavior in such systems when they are 'forced' by an external source of the smallest particles. The corresponding self-similar coagulation spectra prove to be power laws. Starting from the classical Smoluchowski coagulation equation, we identify the conditions required for emergence of self-similarity and show that the power-law exponent value for a particular coagulation mechanism depends on the homogeneity index of the corresponding coagulation kernel only. Next, we consider the current wave of mergers of large American banks as an 'unorthodox' application of coagulation theory. We predict that the bank size distribution has propensity to become a power law, and verify our prediction in a statistical study of the available economical data. We conclude this chapter by discussing economically significant phenomenon of capital condensation and predicting emergence of power-law distributions in other economical and social data. Finally, we turn to apparent semblance between cluster coagulation and turbulence and conclude that it is not accidental: both of these processes are instances of nonlinear cascades. This class of processes also includes river network formation models, certain force-chain models in granular mechanics, fragmentation due to collisional cascades, percolation, and growing random networks. We characterize a particular cascade by three indicies and show that the resulting power-law spectrum exponent depends on the indicies values only. The ensuing algebraic formula is remarkable for its simplicity.

  3. Enhanced WWTP effluent organic matter removal in hybrid ozonation-coagulation (HOC) process catalyzed by Al-based coagulant

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Xin [School of Environmental and Municipal Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi Province, 710055 (China); Jin, Pengkang, E-mail: pkjin@hotmail.com [School of Environmental and Municipal Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi Province, 710055 (China); Hou, Rui [School of Environmental and Municipal Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi Province, 710055 (China); Yang, Lei [Department of Materials Science and Engineering, Monash University, Clayton, VIC, 3800 (Australia); Wang, Xiaochang C., E-mail: xcwang@xauat.edu.cn [School of Environmental and Municipal Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi Province, 710055 (China)

    2017-04-05

    Highlights: • A novel HOC process was firstly put forward to apply in wastewater reclamation. • Interactions between ozone and Al-based coagulants was found in the HOC process. • Ozonation can be catalyzed and enhanced by Al-based coagulants in the HOC process. • HOC process showed better organics removal than pre-ozonation-coagulation process. - Abstract: A novel hybrid ozonation-coagulation (HOC) process was developed for application in wastewater reclamation. In this process, ozonation and coagulation occurred simultaneously within a single unit. Compared with the conventional pre-ozonation-coagulation process, the HOC process exhibited much better performance in removing dissolved organic matters. In particular, the maximal organic matters removal efficiency was obtained at the ozone dosage of 1 mgO{sub 3}/mg DOC at each pH value (pH 5, 7 and 9). In order to interpret the mechanism of the HOC process, ozone decomposition was monitored. The results indicated that ozone decomposed much faster in the HOC process. Moreover, by using the reagent of O{sub 3}-resistant hydroxyl radical (·OH) probe compound, para-chlorobenzoic acid (pCBA), and electron paramagnetic resonance (EPR) analysis, it was observed that the HOC process generated higher content of ·OH compared with pre-ozonation process. This indicates that the ·OH oxidation reaction as the key step can be catalyzed and enhanced by Al-based coagulants and their hydrolyzed products in this developed process. Thus, based on the catalytic effects of Al-based coagulants on ozonation, the HOC process provides a promising alternative to the conventional technology for wastewater reclamation in terms of higher efficiency.

  4. An in vitro analysis of the effect of acidosis on coagulation in chronic disease states - a thromboelastograph study.

    Science.gov (United States)

    White, Hayden; Bird, Robert; Sosnowski, Kellie; Jones, Mark

    2016-06-01

    Thrombosis is a complication of many chronic illnesses. Chronic obstructive pulmonary disease (COPD) and diabetes mellitus are common medical conditions frequently associated with a hypercoagulable state. Acidaemia has been shown to reduce coagulation. COPD and diabetes mellitus during acute deterioration can present with a severe acidaemia. The impact of this acidaemia on coagulation is poorly studied. Patients presenting with a diagnosis of diabetic ketoacidosis or type II respiratory failure from COPD and a pH of less than 7.2 were included in our study. A coagulation screen and a thromboelastograph (TEG) were performed on admission and 24 hours later. The mean pH on admission was 7.07 and mean base excess was -16.3. The activated partial thromboplastin time was associated with pH change but remained within the normal range (26-41 s). All other coagulation and TEG parameters failed to show evidence of association (p>0.05). In the two models of non-haemorrhagic acidosis investigated, coagulation was not altered by the changes in pH. More work is needed to understand the complex relationship between factors affecting coagulation in individual disease processes. © 2016 Royal College of Physicians.

  5. THE RATIONALIZATION OF THE PARAMETERS OF MILK PROTEINS’ THERMO ACID COAGULATION BY BERRY COAGULANTS

    Directory of Open Access Journals (Sweden)

    Olena GREK

    2017-03-01

    Full Text Available This paper presents the results related to the influence of berry coagulant amount, its proactive acidity and duration of thermo acid coagulation on the process of milk proteins’ sedimentation. In the present work, the regression equations and response surface analysis were used to design and optimize an industrial bioprocess. Increase in the berry coagulant amount to 11 % and reduction of active acidity to 2.4 units were determined. pH up to 3 minutes is characterized by the highest processes of destabilization. Moreover, it improves the organoleptic properties and has the biggest impact on the yield of protein-berry clot (to 25 % and active acidity.

  6. Rational and timely haemostatic interventions following cardiac surgery - coagulation factor concentrates or blood bank products.

    Science.gov (United States)

    Tang, Mariann; Fenger-Eriksen, Christian; Wierup, Per; Greisen, Jacob; Ingerslev, Jørgen; Hjortdal, Vibeke; Sørensen, Benny

    2017-06-01

    Cardiac surgery may cause a serious coagulopathy leading to increased risk of bleeding and transfusion demands. Blood bank products are commonly first line haemostatic intervention, but has been associated with hazardous side effect. Coagulation factor concentrates may be a more efficient, predictable, and potentially a safer treatment, although prospective clinical trials are needed to further explore these hypotheses. This study investigated the haemostatic potential of ex vivo supplementation of coagulation factor concentrates versus blood bank products on blood samples drawn from patients undergoing cardiac surgery. 30 adults were prospectively enrolled (mean age=63.9, females=27%). Ex vivo haemostatic interventions (monotherapy or combinations) were performed in whole blood taken immediately after surgery and two hours postoperatively. Fresh-frozen plasma, platelets, cryoprecipitate, fibrinogen concentrate, prothrombin complex concentrate (PCC), and recombinant FVIIa (rFVIIa) were investigated. The haemostatic effect was evaluated using whole blood thromboelastometry parameters, as well as by thrombin generation. Immediately after surgery the compromised maximum clot firmness was corrected by monotherapy with fibrinogen or platelets or combination therapy with fibrinogen. At two hours postoperatively the coagulation profile was further deranged as illustrated by a prolonged clotting time, a reduced maximum velocity and further diminished maximum clot firmness. The thrombin lagtime was progressively prolonged and both peak thrombin and endogenous thrombin potential were compromised. No monotherapy effectively corrected all haemostatic abnormalities. The most effective combinations were: fibrinogen+rFVIIa or fibrinogen+PCC. Blood bank products were not as effective in the correction of the coagulopathy. Coagulation factor concentrates appear to provide a more optimal haemostasis profile following cardiac surgery compared to blood bank products. Copyright © 2017

  7. Hemorrhoidectomy: pedicle ligation vs pedicle coagulation

    International Nuclear Information System (INIS)

    Shaikh, B.S.; Balaoch, I.B.; Sohu, K.M.

    2015-01-01

    Objective: To compare the outcome of pedicle ligation vs pedicle coagulation haemorrhoidectomy. Methodology: This comparative prospective study was carried out at Department of Surgery, Ghulam Muhammad Maher Medcial College Hospital, Sukkur, Pakistan from January 2011 to January 2013 and included 300 patients of hemorrhoids. After routine workup, patients were randomly divided into two equal groups with one group receiving pedicle ligation and other pedicle coagulation for hemorrhoidectomy. Postoperatively they were followed for a period of 8 weeks for complications including pain, urinary retention, bleeding and anal stricture. Pain was recorded up to 10th postoperative day on the basis of visual analogue scale. Results: Mean age was 45 years and male to female ratio was 1.7:1. Mean operative time in pedicle ligation group was 15 min (range 14-20 min) and 17 min (15-25 min) in pedicle coagulation group. In Pedicle ligation group, pain was worst in 35 patients, moderate in 85 and mild in 30 patients; on the other hand in pedicle coagulation group, just 09 patients experienced worst pain. Urinary retention was observed in 44 patients in pedicle ligation group and 19 in pedicle coagulation group. Five patients in pedicle ligation group developed bleeding after their discharge from hospital; 7 patients in pedicle coagulation group reported secondary bleeding. Anal stricture was a rare complication and was found equally common in both the groups. Conclusion: Conventional hemorrhoidectomy with pedicle coagulation is an effective treatment modality for hemorrhoids and is associated with less chance of postoperative anal pain and urinary retention. (author)

  8. Coagulants modulate the hypocholesterolemic effect of tofu ...

    African Journals Online (AJOL)

    hope&shola

    2006-02-02

    Feb 2, 2006 ... The recent increase in soymilk and tofu (coagulated soymilk) consumption especially in western countries is due to the recognition of the health benefits of soy foods. The amount and the type of coagulated biomolecules (such as isoflavones) vary with the type of coagulant, and this will inevitable alter their ...

  9. Contact activation of blood-plasma coagulation

    Science.gov (United States)

    Golas, Avantika

    Surface engineering of biomaterials with improved hemocompatibility is an imperative, given the widespread global need for cardiovascular devices. Research summarized in this dissertation focuses on contact activation of FXII in buffer and blood plasma frequently referred to as autoactivation. The extant theory of contact activation imparts FXII autoactivation ability to negatively charged, hydrophilic surfaces. According to this theory, contact activation of plasma involves assembly of proteins comprising an "activation complex" on activating surfaces mediated by specific chemical interactions between complex proteins and the surface. This work has made key discoveries that significantly improve our core understanding of contact activation and unravel the existing paradigm of plasma coagulation. It is shown herein that contact activation of blood factor XII (FXII, Hageman factor) in neat-buffer solution exhibits a parabolic profile when scaled as a function of silanized-glass-particle activator surface energy (measured as advancing water adhesion tension t°a=g° Iv costheta in dyne/cm, where g°Iv is water interfacial tension in dyne/cm and theta is the advancing contact angle). Nearly equal activation is observed at the extremes of activator water-wetting properties --36 moderated by adsorption of plasma proteins unrelated to coagulation through an "adsorption-dilution" effect that blocks FXII contact with hydrophobic activator surfaces. The adsorption-dilution effect explains the apparent specificity for hydrophilic activators pursued by earlier investigators. Finally a comparison of FXII autoactivation in buffer, serum, protein cocktail, and plasma solutions is shown herein. Activation of blood plasma coagulation in vitro by contact with material surfaces is demonstrably dependent on plasma-volume-to-activator-surface-area ratio. However, activation of factor XII dissolved in buffer, protein cocktail, heat-denatured serum, and FXI deficient plasma does not

  10. Enhanced coagulation activation in preeclampsia: the role of APC resistance, microparticles and other plasma constituents

    NARCIS (Netherlands)

    VanWijk, Marja J.; Boer, Kees; Berckmans, René J.; Meijers, Joost C. M.; van der Post, Joris A. M.; Sturk, Augueste; VanBavel, Ed; Nieuwland, Rienk

    2002-01-01

    Coagulation activation in pregnancy is further enhanced in preeclampsia. We investigated whether this results from increased thrombin generation by the plasma itself or its cell-derived microparticles. Plasma samples were obtained from preeclamptic, normal pregnant and nonpregnant women (each n =

  11. Incidence and Risk Factors of Coagulation Profile Derangement After Liver Surgery: Implications for the Use of Epidural Analgesia-A Retrospective Cohort Study.

    Science.gov (United States)

    Jacquenod, Pierre; Wallon, Grégoire; Gazon, Mathieu; Darnis, Benjamin; Pradat, Pierre; Virlogeux, Victor; Farges, Olivier; Aubrun, Frédéric

    2018-04-01

    Hepatic surgery is a major abdominal surgery. Epidural analgesia may decrease the incidence of postoperative morbidities. Hemostatic disorders frequently occur after hepatic resection. Insertion or withdrawal (whether accidental or not) of an epidural catheter during coagulopathic state may cause an epidural hematoma. The aim of the study is to determine the incidence of coagulopathy after hepatectomy, interfering with epidural catheter removal, and to identify the risk factors related to coagulopathy. We performed a retrospective review of a prospective, multicenter, observational database including patients over 18 years old with a history of liver resection. Main collected data were the following: age, preexisting cirrhosis, Child-Pugh class, preoperative and postoperative coagulation profiles, extent of liver resection, blood loss, blood products transfused during surgery. International normalized ratio (INR) ≥1.5 and/or platelet count <80,000/mm defined coagulopathy according to the neuraxial anesthesia guidelines. A logistic regression analysis was performed to assess the association between selected factors and a coagulopathic state after hepatic resection. One thousand three hundred seventy-one patients were assessed. Seven hundred fifty-nine patients had data available about postoperative coagulopathy, which was observed in 53.5% [95% confidence interval, 50.0-57.1]. Maximum derangement in INR occurred on the first postoperative day, and platelet count reached a trough peak on postoperative days 2 and 3. In the multivariable analysis, preexisting hepatic cirrhosis (odds ratio [OR] = 2.49 [1.38-4.51]; P = .003), preoperative INR ≥1.3 (OR = 2.39 [1.10-5.17]; P = .027), preoperative platelet count <150 G/L (OR = 3.03 [1.77-5.20]; P = .004), major hepatectomy (OR = 2.96 [2.07-4.23]; P < .001), and estimated intraoperative blood loss ≥1000 mL (OR = 1.85 [1.08-3.18]; P = .025) were associated with postoperative coagulopathy. Coagulopathy is frequent (53

  12. Coagulation system changes associated with susceptibility to infection in trauma patients.

    Science.gov (United States)

    Cole, Elaine; Davenport, Ross; De'Ath, Henry; De-Ath, Henry; Manson, Joanna; Brockamp, Thomas; Brohi, Karim

    2013-01-01

    Infection following trauma is associated with increased morbidity and mortality and is common following severe hemorrhage. There is a strong interaction between the coagulation and immunity. The objective of this study was to establish if there was an association between changes in coagulation status after hemorrhage and the subsequent incidence of infection. Prospective cohort study of adult injured patients presenting to a major trauma center during a 2-year period. Blood was drawn at 24 hours following admission and analyzed using functional thromboelastography testing and laboratory defined tests of coagulation and blood count. Patients were followed up for infectious episodes while in the hospital using Center for Disease Control definitions. A total of 158 patients were recruited; 71 (45%) developed infection and were older (44 years vs. 32 years, p = 0.01) and more severely injured (Injury Severity Score [ISS], 25 vs.10; p < 0.01). White blood cell counts at 24 hours were normal, and there was no difference between groups (both 9.6 × 10/(9)L). Protein C was lower in those with infection (70.2 IU/dL vs. 83.3 IU/dL, p = 0.02), with a dose-dependent increase in infection as levels of protein C decreased. Plasmin activation at 24 hours was also strongly associated with infection plasmin-antiplasmin (infection vs. no infection, 6,156 μg/L vs. 3,324 μg/L, p = 0.03). The infection cohort had overall 12% lower procoagulant levels (varied between factor VIII 6.4% and factor II 16.2%). There is a strong association between the status of the coagulation system after 24 hours and the development of infection following trauma. Improved early coagulation management may decrease infection rates in this patient group. Prognostic prospective study, level III.

  13. Coagulant recovery and reuse for drinking water treatment.

    Science.gov (United States)

    Keeley, James; Jarvis, Peter; Smith, Andrea D; Judd, Simon J

    2016-01-01

    Coagulant recovery and reuse from waterworks sludge has the potential to significantly reduce waste disposal and chemicals usage for water treatment. Drinking water regulations demand purification of recovered coagulant before they can be safely reused, due to the risk of disinfection by-product precursors being recovered from waterworks sludge alongside coagulant metals. While several full-scale separation technologies have proven effective for coagulant purification, none have matched virgin coagulant treatment performance. This study examines the individual and successive separation performance of several novel and existing ferric coagulant recovery purification technologies to attain virgin coagulant purity levels. The new suggested approach of alkali extraction of dissolved organic compounds (DOC) from waterworks sludge prior to acidic solubilisation of ferric coagulants provided the same 14:1 selectivity ratio (874 mg/L Fe vs. 61 mg/L DOC) to the more established size separation using ultrafiltration (1285 mg/L Fe vs. 91 mg/L DOC). Cation exchange Donnan membranes were also examined: while highly selective (2555 mg/L Fe vs. 29 mg/L DOC, 88:1 selectivity), the low pH of the recovered ferric solution impaired subsequent treatment performance. The application of powdered activated carbon (PAC) to ultrafiltration or alkali pre-treated sludge, dosed at 80 mg/mg DOC, reduced recovered ferric DOC contamination to water quality parameters. Several PAC-polished recovered coagulants provided the same or improved DOC and turbidity removal as virgin coagulant, as well as demonstrating the potential to reduce disinfection byproducts and regulated metals to levels comparable to that attained from virgin material. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Magnetic Resonance Mediated Radio Frequency Coagulation for Vascular Repair

    Science.gov (United States)

    Zhao, Ming

    Purpose. Magnetic Resonance Mediated Radiofrequency Coagulation employs the RF heating effect of MRI scanning to coagulate biomaterials for repair of vascular defects. Coagulation of a protein biomaterial by MR-induced RF heating is a novel means to effect repair of defects such as aneurysms or arteriovenous malformations. Our novel method is to coagulate a thermosetting material (such as egg white, which can be used for investigating heat coagulation behavior and MR relaxation properties) delivered endovascularly by catheter and coagulated by RF-induced heating of an intracatheter resonant wire antenna in the scanner. Methods. Experiments were performed on a Siemens 1.5 T MRI scanner and a Bruker 14T NMR spectrometer. Egg white was brought to equilibrium at seven temperatures (20, 30, 40, 50, 60, 70 and 37 °C) in sequence. Measurement of the water spin-lattice relaxation time Ti, spin-spin relaxation time T2, spin-lattice relaxation time in the rotating frame T1p, or full width at half maximum of the MT spectrum were performed at each temperature. Relaxation parameters of raw egg white and egg white after coagulation at 70 °C were measured in the scanner at 20 °C to determine optimum inversion time, echo time and offset frequency for good image contrast between coagulated and uncoagulated protein. Finally, coagulation of egg white within a glass aneurysm phantom by RF heating in the scanner was performed to demonstrate the MR coagulation methodology and the ability to achieve image contrast between coagulated and uncoagulated biomaterial. Results. Water T2, T1p and MT gave the most definitive indication of the change from uncoagulated at low temperature to fully coagulated at 60 °C, while water T1 showed only the expected gradual increase with temperature, and no response to coagulation. MT weighted imaging is expected to be the optimum method to establish the coagulation condition of the biomaterial.

  15. Coagulation and Mental Disorders

    Directory of Open Access Journals (Sweden)

    Silvia Hoirisch-Clapauch

    2014-10-01

    Full Text Available The neurovascular unit is a key player in brain development, homeostasis, and pathology. Mental stress affects coagulation, while severe mental illnesses, such as recurrent depression and schizophrenia, are associated with an increased thrombotic risk and cardiovascular morbidity. Evidence indicates that the hemostatic system is involved to some extent in the pathogenesis, morbidity, and prognosis of a wide variety of psychiatric disorders. The current review focuses on emerging data linking coagulation and some psychiatric disorders.

  16. Removal of silver nanoparticles by coagulation processes

    International Nuclear Information System (INIS)

    Sun, Qian; Li, Yan; Tang, Ting; Yuan, Zhihua; Yu, Chang-Ping

    2013-01-01

    Highlights: • This study investigated the removal of AgNP suspensions by four regular coagulants. • The optimal removal efficiencies for the four coagulants were achieved at pH 7.5. • The removal efficiency of AgNPs was affected by the natural water characteristics. • TEM and XRD showed that AgNPs or silver-containing NPs were adsorbed onto the flocs. -- Abstract: Commercial use of silver nanoparticles (AgNPs) will lead to a potential route for human exposure via potable water. Coagulation followed by sedimentation, as a conventional technique in the drinking water treatment facilities, may become an important barrier to prevent human from AgNP exposures. This study investigated the removal of AgNP suspensions by four regular coagulants. In the aluminum sulfate and ferric chloride coagulation systems, the water parameters slightly affected the AgNP removal. However, in the poly aluminum chloride and polyferric sulfate coagulation systems, the optimal removal efficiencies were achieved at pH 7.5, while higher or lower of pH could reduce the AgNP removal. Besides, the increasing natural organic matter (NOM) would reduce the AgNP removal, while Ca 2+ and suspended solids concentrations would also affect the AgNP removal. In addition, results from the transmission electron microscopy and X-ray diffraction showed AgNPs or silver-containing nanoparticles were adsorbed onto the flocs. Finally, natural water samples were used to validate AgNP removal by coagulation. This study suggests that in the case of release of AgNPs into the source water, the traditional water treatment process, coagulation/sedimentation, can remove AgNPs and minimize the silver ion concentration under the well-optimized conditions

  17. Evaluation of the treatment of reverse osmosis concentrates from municipal wastewater reclamation by coagulation and granular activated carbon adsorption.

    Science.gov (United States)

    Sun, Ying-Xue; Yang, Zhe; Ye, Tao; Shi, Na; Tian, Yuan

    2016-07-01

    Reverse osmosis concentrate (ROC) from municipal wastewater reclamation reverse osmosis (mWRRO) contains elevated concentrations of contaminants which pose potential risks to aquatic environment. The treatment of ROC from an mWRRO using granular activated carbon (GAC) combined pretreatment of coagulation was optimized and evaluated. Among the three coagulants tested, ferric chloride (FeCl3) presented relatively higher DOC removal efficiency than polyaluminium chloride and lime at the same dosage and coagulation conditions. The removal efficiency of DOC, genotoxicity, and antiestrogenic activity concentration of the ROC could achieve 16.9, 18.9, and 39.7 %, respectively, by FeCl3 coagulation (with FeCl3 dosage of 180.22 mg/L), which can hardly reduce UV254 and genotoxicity normalized by DOC of the DOM with MW activity were completely eliminated by the GAC adsorption. The results suggest that GAC adsorption combined pretreatment of FeCl3 coagulation as an efficient method to control organics, genotoxicity, and antiestrogenic activity in the ROC from mWRRO system.

  18. Imaging of blood plasma coagulation at supported lipid membranes.

    Science.gov (United States)

    Faxälv, Lars; Hume, Jasmin; Kasemo, Bengt; Svedhem, Sofia

    2011-12-15

    The blood coagulation system relies on lipid membrane constituents to act as regulators of the coagulation process upon vascular trauma, and in particular the 2D configuration of the lipid membranes is known to efficiently catalyze enzymatic activity of blood coagulation factors. This work demonstrates a new application of a recently developed methodology to study blood coagulation at lipid membrane interfaces with the use of imaging technology. Lipid membranes with varied net charges were formed on silica supports by systematically using different combinations of lipids where neutral phosphocholine (PC) lipids were mixed with phospholipids having either positively charged ethylphosphocholine (EPC), or negatively charged phosphatidylserine (PS) headgroups. Coagulation imaging demonstrated that negatively charged SiO(2) and membrane surfaces exposing PS (obtained from liposomes containing 30% of PS) had coagulation times which were significantly shorter than those for plain PC membranes and EPC exposing membrane surfaces (obtained from liposomes containing 30% of EPC). Coagulation times decreased non-linearly with increasing negative surface charge for lipid membranes. A threshold value for shorter coagulation times was observed below a PS content of ∼6%. We conclude that the lipid membranes on solid support studied with the imaging setup as presented in this study offers a flexible and non-expensive solution for coagulation studies at biological membranes. It will be interesting to extend the present study towards examining coagulation on more complex lipid-based model systems. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Effect of nano-scale curvature on the intrinsic blood coagulation system

    Science.gov (United States)

    Kushida, Takashi; Saha, Krishnendu; Subramani, Chandramouleeswaran; Nandwana, Vikas; Rotello, Vincent M.

    2014-11-01

    The intrinsic coagulation activity of silica nanoparticles strongly depends on their surface curvature. Nanoparticles with higher surface curvature do not denature blood coagulation factor XII on its surface, providing a coagulation `silent' surface, while nanoparticles with lower surface curvature show denaturation and concomitant coagulation.The intrinsic coagulation activity of silica nanoparticles strongly depends on their surface curvature. Nanoparticles with higher surface curvature do not denature blood coagulation factor XII on its surface, providing a coagulation `silent' surface, while nanoparticles with lower surface curvature show denaturation and concomitant coagulation. Electronic supplementary information (ESI) available: Physical properties and scanning electron micrographs (SEM) of silica NPs, intrinsic coagulation activity after 3 h. See DOI: 10.1039/c4nr04128c

  20. Treatment of tracheal mucoepidermoid carcinoma by argon plasma coagulation during pregnancy.

    Science.gov (United States)

    Kesrouani, Assaad; Dabar, Georges; Rahal, Samir; Ghorra, Claude

    2015-05-01

    Mucoepidermoid carcinoma of the tracheobronchial tree is a rare airway tumor (cesarean section. We report the first case to be treated by Argon-Plasma Coagulation (APC) in pregnancy. A 35-year-old Caucasian woman G1P0, at 27 weeks of gestation was admitted to the emergency department because of hemoptysis and severe dyspnea. Bronchoscopy and biopsies diagnosed primary tracheal mucoepidermoid carcinoma. Following an episode of tracheal bleeding, she was intubated. After thorough explanations to the family and obtaining informed consent, therapeutic bronchoscopy, under general anesthesia using a rigid bronchoscope, was performed. The tumor was cored out with the tip of the bronchoscope and removed with an alligator forceps. The tumor bed was coagulated with APC. The obstetrical team was ready to intervene in case of maternal emergency. Immediate follow-up was good, and she left the hospital 4 days later. She delivered at 39 weeks of gestation by cesarean section because of dystocia. Five years later, the patient is doing well without any signs or symptoms of recurrence. Pediatric follow-up is normal. Argon Plasma Coagulation for treatment of mucoepidermoid tracheal carcinoma is feasible during pregnancy. Reporting this case could lead to less aggressive management of mucoepidermoid carcinoma in pregnant patients.

  1. Comparison of Moringa stenopetala seed extract as a clean coagulant with Alum and Moringa stenopetala-Alum hybrid coagulant to remove direct dye from Textile Wastewater.

    Science.gov (United States)

    Dalvand, Arash; Gholibegloo, Elham; Ganjali, Mohammad Reza; Golchinpoor, Najmeh; Khazaei, Mohammad; Kamani, Hossein; Hosseini, Sara Sadat; Mahvi, Amir Hossein

    2016-08-01

    In this study, the efficiency of Moringa stenopetala seed extract was compared with alum and M. stenopetala-alum hybrid coagulant to remove Direct Red 23 azo dye from textile wastewater. The effects of parameters such as pH, coagulant dose, type of salt used for the extraction of coagulant and initial dye concentration on dye removal efficiency were investigated. Moreover, the existing functional groups on the structure of M. stenopetala coagulant (MSC) were determined by Fourier transform infrared spectroscopy, and the morphology of sludge produced by MSC, alum, and hybrid coagulant was characterized by scanning electron microscopy. Ninhydrin test was also used to determine the quantity of primary amines in the MSC and Moringa oleifera coagulant (MOC). According to the results, with increasing the coagulant dose and decreasing the initial dye concentration, dye removal efficiency has increased. The maximum dye removal of 98.5, 98.2, and 98.3 % were obtained by using 240, 120, and 80 mg/L MSC, alum and hybrid coagulant at pH 7, respectively. The results also showed MSC was much more effective than MOC for dye removal. The volume of sludge produced by MSC was one fourth and half of those produced by alum and hybrid coagulant, respectively. Based on the results, hybrid coagulant was the most efficient coagulant for direct dye removal from colored wastewater.

  2. Polyferric sulphate: preparation, characterisation and application in coagulation experiments.

    Science.gov (United States)

    Zouboulis, A I; Moussas, P A; Vasilakou, F

    2008-07-15

    The process of coagulation is a core environmental protection technology, which is mainly used in the water or wastewater treatment facilities. Research is now focused on the development of inorganic pre-polymerised coagulants. A characteristic example is PFS (polyferric sulphate), a relatively new pre-polymerised inorganic coagulant with high cationic charge. In this paper, the role of major parameters, including temperature, types of chemical reagents, ratio r=[OH]/[Fe], rate of base addition in the preparation stages of PFS were investigated. Furthermore, the prepared PFS was characterised based on typical properties, such as the percentage of the polymerised iron present in the compound, z-potential, pH, etc. Moreover, dynamics of coagulation process were examined by means of the Photometric Dispersion Analyzer (PDA). Finally, the coagulation efficiency of PFS in treating kaolin suspension and biologically pre-treated wastewater was evaluated in comparison with the respective conventional coagulant agent. The results indicate that certain parameters, such as the r value, the rate of base addition and the duration and temperature of the polymerisation stage, significantly affected the properties of the PFS. Additionally, the prepared PFS polymerised coagulants exhibit a significantly better coagulation performance than the respective non-polymerised one, i.e. ferric sulphate.

  3. Does Lipid Profile Affect Thrombin Generation During Ramadan Fasting in Patients With Cardiovascular Risks?

    Science.gov (United States)

    Sassi, Mouna; Chakroun, Taher; Chouchène, Saoussen; Hellara, Ilhem; Boubaker, Hamdi; Grissa, Mohamed Habib; Khochtali, Ines; Hassine, Mohsen; Addad, Faouzi; Elalamy, Ismail; Nouira, Semir

    2017-11-01

    There is evidence that diet and variation in lipid metabolism can influence blood coagulation, but little is known about the effect of Ramadan fasting on plasmatic coagulation pattern. We investigated the effect of Ramadan fasting on thrombin generation (TG) in patients with cardiovascular disease (CVD) risks, and we aimed to assess the effect of lipid profile on TG parameters. The study was conducted in 36 adults having at least 2 CVD risks and in 30 healthy controls. Coagulation pattern was assessed by both classical clotting times and TG test. A complete lipid profile was performed simultaneously. Patients were invited 2 times: 1 week before Ramadan and during the last week of the Ramadan. The TG parameters were not different in patients with CVD risks compared to healthy controls. Fasting had no effect on plasmatic coagulation parameters and on TG profile. Individual analysis of the mean rate index (MRI) of TG revealed 3 groups: group 1 with no modification of MRI, group 2 with a significant increase in MRI (81.64 nM/min vs 136.07 nM/min; P fasting did not influence the global coagulation pattern in patients with CVD risks. Whereas, a significant increase in the propagation phase of TG was associated with a significant increase in cholesterol levels, which was not found with the other TG parameters.

  4. Coagulation activity in liver disease | Reza | Internet Journal of ...

    African Journals Online (AJOL)

    Patients with advanced hepatic failure may present with the entire spectrum of coagulation factor deficiencies. This study was designed to determine laboratory abnormalities in coagulation in chronic liver disease and the association of these abnormalities with the extent of chronic hepatitis and cirrhosis. Coagulation ...

  5. Characterization of follicle stimulating hormone profiles in normal ovulating women.

    Science.gov (United States)

    Ecochard, René; Guillerm, Agnes; Leiva, René; Bouchard, Thomas; Direito, Ana; Boehringer, Hans

    2014-07-01

    To describe FSH profile variants. Observational study. Multicenter collaborative study. A total of 107 women. Women collected daily first morning urine and underwent serial ovarian ultrasound. The individual FSH cyclic profiles demonstrated a significant departure from the currently accepted model. A decline in FSH levels at the end of the follicular phase was observed in only 42% of cycles. The absence of this decline was significantly associated with a shorter luteal phase and higher pregnanediol-3α-glucuronide, FSH, and LH levels at the time of ovulation. In 34% of the cycles, significant FSH variability was observed throughout the follicular phase; this variability was associated with higher body mass index and lower overall FSH and LH levels throughout the cycle. The FSH peak occurs on average 2 hours before ovulation. The FSH peak duration was shorter than the LH peak. These results suggest that average FSH profiles may not reflect the more complex dynamics of daily hormonal variations in the menstrual cycle. It is possible that discrepancies between the average normal FSH profile and the individual day-to-day variants can be used to detect abnormalities. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  6. Normal Coagulation

    Science.gov (United States)

    2014-09-04

    factor VIII, or hemophilia A, is a well- characterized bleeding disorder linked to the X chromosome . Severe hemophilia A therefore occurs almost... disappears from the fluid phase of the reaction. Thus, the “initial clot” is a mixture composed of fibrin and fibrinogen. with the somatomedin B

  7. Host defense peptides of thrombin modulate inflammation and coagulation in endotoxin-mediated shock and Pseudomonas aeruginosa sepsis.

    Science.gov (United States)

    Kalle, Martina; Papareddy, Praveen; Kasetty, Gopinath; Mörgelin, Matthias; van der Plas, Mariena J A; Rydengård, Victoria; Malmsten, Martin; Albiger, Barbara; Schmidtchen, Artur

    2012-01-01

    Gram-negative sepsis is accompanied by a disproportionate innate immune response and excessive coagulation mainly induced by endotoxins released from bacteria. Due to rising antibiotic resistance and current lack of other effective treatments there is an urgent need for new therapies. We here present a new treatment concept for sepsis and endotoxin-mediated shock, based on host defense peptides from the C-terminal part of human thrombin, found to have a broad and inhibitory effect on multiple sepsis pathologies. Thus, the peptides abrogate pro-inflammatory cytokine responses to endotoxin in vitro and in vivo. Furthermore, they interfere with coagulation by modulating contact activation and tissue factor-mediated clotting in vitro, leading to normalization of coagulation responses in vivo, a previously unknown function of host defense peptides. In a mouse model of Pseudomonas aeruginosa sepsis, the peptide GKY25, while mediating a modest antimicrobial effect, significantly inhibited the pro-inflammatory response, decreased fibrin deposition and leakage in the lungs, as well as reduced mortality. Taken together, the capacity of such thrombin-derived peptides to simultaneously modulate bacterial levels, pro-inflammatory responses, and coagulation, renders them attractive therapeutic candidates for the treatment of invasive infections and sepsis.

  8. Host defense peptides of thrombin modulate inflammation and coagulation in endotoxin-mediated shock and Pseudomonas aeruginosa sepsis.

    Directory of Open Access Journals (Sweden)

    Martina Kalle

    Full Text Available Gram-negative sepsis is accompanied by a disproportionate innate immune response and excessive coagulation mainly induced by endotoxins released from bacteria. Due to rising antibiotic resistance and current lack of other effective treatments there is an urgent need for new therapies. We here present a new treatment concept for sepsis and endotoxin-mediated shock, based on host defense peptides from the C-terminal part of human thrombin, found to have a broad and inhibitory effect on multiple sepsis pathologies. Thus, the peptides abrogate pro-inflammatory cytokine responses to endotoxin in vitro and in vivo. Furthermore, they interfere with coagulation by modulating contact activation and tissue factor-mediated clotting in vitro, leading to normalization of coagulation responses in vivo, a previously unknown function of host defense peptides. In a mouse model of Pseudomonas aeruginosa sepsis, the peptide GKY25, while mediating a modest antimicrobial effect, significantly inhibited the pro-inflammatory response, decreased fibrin deposition and leakage in the lungs, as well as reduced mortality. Taken together, the capacity of such thrombin-derived peptides to simultaneously modulate bacterial levels, pro-inflammatory responses, and coagulation, renders them attractive therapeutic candidates for the treatment of invasive infections and sepsis.

  9. Coagulation and Adsorption Treatment of Printing Ink Wastewater

    OpenAIRE

    Klančnik, Maja

    2014-01-01

    The intention of the study was to improve the efficiency of total organic carbon (TOC) and colour removal from the wastewater samples polluted with flexographic printing ink following coagulation treatments with further adsorption onto activated carbons and ground orange peel. The treatment efficiencies were compared to those of further flocculation treatments and of coagulation and adsorption processes individually. Coagulation was a relatively effective single-treatment method, removing 99...

  10. SwathProfiler and NProfiler: Two new ArcGIS Add-ins for the automatic extraction of swath and normalized river profiles

    Science.gov (United States)

    Pérez-Peña, J. V.; Al-Awabdeh, M.; Azañón, J. M.; Galve, J. P.; Booth-Rea, G.; Notti, D.

    2017-07-01

    The present-day great availability of high-resolution Digital Elevation Models has improved tectonic geomorphology analyses in their methodological aspects and geological meaning. Analyses based on topographic profiles are valuable to explore the short and long-term landscape response to tectonic activity and climate changes. Swath and river longitudinal profiles are two of the most used analysis to explore the long and short-term landscape responses. Most of these morphometric analyses are conducted in GIS software, which have become standard tools for analyzing drainage network metrics. In this work we present two ArcGIS Add-Ins to automatically delineate swath and normalized river profiles. Both tools are programmed in Visual Basic . NET and use ArcObjects library-architecture to access directly to vector and raster data. The SwathProfiler Add-In allows analyzing the topography within a swath or band by representing maximum-minimum-mean elevations, first and third quartile, local relief and hypsometry. We have defined a new transverse hypsometric integral index (THi) that analyzes hypsometry along the swath and offer valuable information in these kind of graphics. The NProfiler Add-In allows representing longitudinal normalized river profiles and their related morphometric indexes as normalized concavity (CT), maximum concavity (Cmax) and length of maximum concavity (Lmax). Both tools facilitate the spatial analysis of topography and drainage networks directly in a GIS environment as ArcMap and provide graphical outputs. To illustrate how these tools work, we analyzed two study areas, the Sierra Alhamilla mountain range (Betic Cordillera, SE Spain) and the Eastern margin of the Dead Sea (Jordan). The first study area has been recently studied from a morphotectonic perspective and these new tools can show an added value to the previous studies. The second study area has not been analyzed by quantitative tectonic geomorphology and the results suggest a landscape

  11. The immediate and late effects of thyroid hormone (triiodothyronine) on murine coagulation gene transcription.

    Science.gov (United States)

    Salloum-Asfar, Salam; Boelen, Anita; Reitsma, Pieter H; van Vlijmen, Bart J M

    2015-01-01

    Thyroid dysfunction is associated with changes in coagulation. The aim of our study was to gain more insight into the role of thyroid hormone in coagulation control. C57Black/6J mice received a low-iodine diet and drinking water supplemented with perchlorate to suppress endogenous triiodothyronine (T3) and thyroxine (T4) production. Under these conditions, the impact of exogenous T3 on plasma coagulation, and hepatic and vessel-wall-associated coagulation gene transcription was studied in a short- (4 hours) and long-term (14 days) setting. Comparing euthyroid conditions (normal mice), with hypothyroidism (conditions of a shortage of thyroid hormone) and those with replacement by incremental doses of T3, dosages of 0 and 0.5 μg T3/mouse/day were selected to study the impact of T3 on coagulation gene transcription. Under these conditions, a single injection of T3 injection increased strongly hepatic transcript levels of the well-characterized T3-responsive genes deiodinase type 1 (Dio1) and Spot14 within 4 hours. This coincided with significantly reduced mRNA levels of Fgg, Serpinc1, Proc, Proz, and Serpin10, and the reduction of the latter three persisted upon daily treatment with T3 for 14 days. Prolonged T3 treatment induced a significant down-regulation in factor (F) 2, F9 and F10 transcript levels, while F11 and F12 levels increased. Activity levels in plasma largely paralleled these mRNA changes. Thbd transcript levels in the lung (vessel-wall-associated coagulation) were significantly up-regulated after a single T3 injection, and persisted upon prolonged T3 exposure. Two-week T3 administration also resulted in increased Vwf and Tfpi mRNA levels, whereas Tf levels decreased. These data showed that T3 has specific effects on coagulation, with Fgg, Serpinc1, Proc, Proz, Serpin10 and Thbd responding rapidly, making these likely direct thyroid hormone receptor targets. F2, F9, F10, F11, F12, Vwf, Tf and Tfpi are late responding genes and probably indirectly

  12. Effect of nano-scale curvature on the intrinsic blood coagulation system

    Science.gov (United States)

    Kushida, Takashi; Saha, Krishnendu; Subramani, Chandramouleeswaran; Nandwana, Vikas; Rotello, Vincent M.

    2014-01-01

    The intrinsic coagulation activity of silica nanoparticles strongly depends on their surface curvature. Nanoparticles with higher surface curvature do not denature blood coagulation factor XII on its surface, providing a coagulation ‘silent’ surface, while nanoparticles with lower surface curvature shows denaturation and concomitant coagulation. PMID:25341004

  13. From Intensity Profile to Surface Normal: Photometric Stereo for Unknown Light Sources and Isotropic Reflectances.

    Science.gov (United States)

    Lu, Feng; Matsushita, Yasuyuki; Sato, Imari; Okabe, Takahiro; Sato, Yoichi

    2015-10-01

    We propose an uncalibrated photometric stereo method that works with general and unknown isotropic reflectances. Our method uses a pixel intensity profile, which is a sequence of radiance intensities recorded at a pixel under unknown varying directional illumination. We show that for general isotropic materials and uniformly distributed light directions, the geodesic distance between intensity profiles is linearly related to the angular difference of their corresponding surface normals, and that the intensity distribution of the intensity profile reveals reflectance properties. Based on these observations, we develop two methods for surface normal estimation; one for a general setting that uses only the recorded intensity profiles, the other for the case where a BRDF database is available while the exact BRDF of the target scene is still unknown. Quantitative and qualitative evaluations are conducted using both synthetic and real-world scenes, which show the state-of-the-art accuracy of smaller than 10 degree without using reference data and 5 degree with reference data for all 100 materials in MERL database.

  14. Research and clinical applications of iodine-123 fibrinogen in coagulation disorders

    International Nuclear Information System (INIS)

    DeNardo, G.L.; DeNardo, S.J.; Swanson, M.A.; Wortman, J.A.; Twardock, A.R.; Colcher, D.

    1985-01-01

    A great many proteins are available to serve as molecular substrates suitable for investigation of normal and diseased states. These proteins, labeled with the appropriate radioisotope of iodine, can be used for immunoassays, imaging, and systemic radiotherapy. The authors describe 12 years experience using coagulation proteins for the investigation of cancer, venous thrombosis, renal transplant rejection, and other coagulopathies. Scintigraphy with 123 I-fibrinogen and immunoassays for circulating antigens such as fibrinopeptide A appear to be promising diagnostic, as well as investigative, tools

  15. Treatment of waste water by coagulation and flocculation using biomaterials

    Science.gov (United States)

    Muruganandam, L.; Saravana Kumar, M. P.; Jena, Amarjit; Gulla, Sudiv; Godhwani, Bhagesh

    2017-11-01

    The present study deals with the determination of physical and chemical parameters in the treatment process of waste water by flocculation and coagulation processes using natural coagulants and assessing their feasibility for water treatment by comparing the performance with each other and with a synthetic coagulant. Initial studies were done on the synthetic waste water to determine the optimal pH and dosage, the activity of natural coagulant, followed by the real effluent from tannery waste. The raw tannery effluent was bluish-black in colour, mildly basic in nature, with high COD 4000mg/l and turbidity in the range 700NTU, was diluted and dosed with organic coagulants, AloeVera, MoringaOleifera and Cactus (O.ficus-indica). The study observed that coagulant Moringa Oleifera of 15 mg/L dose at 6 pH gave the best reduction efficiencies for major physicochemical parameters followed by Aloe Vera and Cactus under identical conditions. The study reveals that the untreated tannery effluents can be treated with environmental confirmative naturally occurring coagulants.

  16. Coagulation chemistries for silica removal from cooling tower water.

    Energy Technology Data Exchange (ETDEWEB)

    Nyman, May Devan; Altman, Susan Jeanne; Stewart, Tom

    2010-02-01

    The formation of silica scale is a problem for thermoelectric power generating facilities, and this study investigated the potential for removal of silica by means of chemical coagulation from source water before it is subjected to mineral concentration in cooling towers. In Phase I, a screening of many typical as well as novel coagulants was carried out using concentrated cooling tower water, with and without flocculation aids, at concentrations typical for water purification with limited results. In Phase II, it was decided that treatment of source or make up water was more appropriate, and that higher dosing with coagulants delivered promising results. In fact, the less exotic coagulants proved to be more efficacious for reasons not yet fully determined. Some analysis was made of the molecular nature of the precipitated floc, which may aid in process improvements. In Phase III, more detailed study of process conditions for aluminum chloride coagulation was undertaken. Lime-soda water softening and the precipitation of magnesium hydroxide were shown to be too limited in terms of effectiveness, speed, and energy consumption to be considered further for the present application. In Phase IV, sodium aluminate emerged as an effective coagulant for silica, and the most attractive of those tested to date because of its availability, ease of use, and low requirement for additional chemicals. Some process optimization was performed for coagulant concentration and operational pH. It is concluded that silica coagulation with simple aluminum-based agents is effective, simple, and compatible with other industrial processes.

  17. Comparison of the Performance of Corn Starch Coagulant Aid Accompany with Alum, Polyaluminum Chloride and Ferric Chloride Coagulants in Turbidity Removal from Water

    Directory of Open Access Journals (Sweden)

    Leila Mosleh

    2014-09-01

    Full Text Available Background: The most important process in water treatment plant is coagulation and flocculation. Regular chemical coagulant which used in Iran are aluminum sulfate (Alum and ferric chloride. Chemical coagulants have hazardous effect on human health and their cost is high for developing country. The purpose of this study was to evaluate the comparison of chemical coagulants accompany with corn starch as a coagulant aid, for the turbidity removal from water. Methods: This study was accomplished in pilot-scale with synthetic turbid water using clay. In this research, initial turbidity of 250 and 500 NTU was experimented. Chemical coagulant dose during the experiment was 1, 2 and 5 ppm and natural coagulant dose was 0, 0.1, 0.3, 0.5 and 0.7 ppm. Results: The results showed that maximum removal efficiency of turbidity in initial turbidity of 250 NTU belonged to poly aluminum chloride with 5 ppm dosage and corn starch with 0.7 ppm dosage which removed and reduced the initial turbidity to 98.48% and 3.73 NTU, respectively. Moreover, in initial turbidity of 500 NTU the maximum removal efficiency was 98.52% which belonged to ferric chloride and corn starch (5 and 0.7 ppm respectively and reduced the initial turbidity to 7.4 NTU. Conclusions: The results of this study showed that using natural coagulant aid reduce the chemical coagulant consumption, and also does not have significant effect on pH range and reduce the health risks. While huge amount of required polyelectrolytes for water treatment plant imported to the country and the production of corn starch in our country is high, it is hope that the results of this project can be used in industrial scale.

  18. Coagulation and inflammation

    NARCIS (Netherlands)

    van der Poll, T.

    2001-01-01

    Severe infection induces both activation of the coagulation system and multiple other inflammatory mediator cascades. This concise review summarizes the current knowledge of mechanisms that are considered to contribute to the procoagulant response to sepsis. Furthermore, evidence is discussed that

  19. Bio-responsive polymer hydrogels homeostatically regulate blood coagulation.

    Science.gov (United States)

    Maitz, Manfred F; Freudenberg, Uwe; Tsurkan, Mikhail V; Fischer, Marion; Beyrich, Theresa; Werner, Carsten

    2013-01-01

    Bio-responsive polymer architectures can empower medical therapies by engaging molecular feedback-response mechanisms resembling the homeostatic adaptation of living tissues to varying environmental constraints. Here we show that a blood coagulation-responsive hydrogel system can deliver heparin in amounts triggered by the environmental levels of thrombin, the key enzyme of the coagulation cascade, which--in turn--becomes inactivated due to released heparin. The bio-responsive hydrogel quantitatively quenches blood coagulation over several hours in the presence of pro-coagulant stimuli and during repeated incubation with fresh, non-anticoagulated blood. These features enable the introduced material to provide sustainable, autoregulated anticoagulation, addressing a key challenge of many medical therapies. Beyond that, the explored concept may facilitate the development of materials that allow the effective and controlled application of drugs and biomolecules.

  20. Thrombelastography and biomarker profiles in acute coagulopathy of trauma: a prospective study

    Directory of Open Access Journals (Sweden)

    Larsen Claus F

    2011-10-01

    Full Text Available Abstract Background Severe injury induces an acute coagulopathy associated with increased mortality. This study compared the Thrombelastography (TEG and biomarker profiles upon admission in trauma patients. Methods Prospective observational study of 80 trauma patients admitted to a Level I Trauma Centre. Data on demography, biochemistry including standard coagulation tests, hematology, transfusions, Injury Severity Score (ISS and TEG were recorded. Retrospective analysis of thawed plasma/serum for biomarkers reflecting tissue injury (histone-complexed DNA fragments, sympathoadrenal activation (adrenaline, noradrenaline, coagulation activation/inhibition and fibrinolysis (sCD40L, protein C, activated Protein C, tissue-type plasminogen activator, plasminogen activator inhibitor-1, D-dimer, prothrombinfragment 1+2, plasmin/α2-antiplasmin complex, thrombin/antithrombin complex, tissue factor pathway inhibitor, antithrombin, von willebrand factor, factor XIII. Comparison of patients stratified according to ISS/TEG maximum clot strength. Linear regression analysis of variables associated with clot strength. Results Trauma patients had normal (86%, hypercoagulable (11% or hypocoagulable (1% TEG clot strength; one had primary hyperfibrinolysis. Hypercoagulable patients had higher age, fibrinogen and platelet count (all p 10 red blood cells the initial 24 h. Patients with normal or hypercoagulable TEG clot strength had comparable biomarker profiles, but the few patients with hypocoagulable TEG clot strength and/or hyperfibrinolysis had very different biomarker profiles. Increasing ISS was associated with higher levels of catecholamines, histone-complexed DNA fragments, sCD40L, activated protein C and D-dimer and reduced levels of non-activated protein C, antithrombin, fibrinogen and factor XIII (all p 26. In patients with ISS > 26, adrenaline and sCD40L were independently negatively associated with clot strength. Conclusions Trauma patients displayed

  1. Significant effect of topographic normalization of airborne LiDAR data on the retrieval of plant area index profile in mountainous forests

    Science.gov (United States)

    Liu, Jing; Skidmore, Andrew K.; Heurich, Marco; Wang, Tiejun

    2017-10-01

    As an important metric for describing vertical forest structure, the plant area index (PAI) profile is used for many applications including biomass estimation and wildlife habitat assessment. PAI profiles can be estimated with the vertically resolved gap fraction from airborne LiDAR data. Most research utilizes a height normalization algorithm to retrieve local or relative height by assuming the terrain to be flat. However, for many forests this assumption is not valid. In this research, the effect of topographic normalization of airborne LiDAR data on the retrieval of PAI profile was studied in a mountainous forest area in Germany. Results show that, although individual tree height may be retained after topographic normalization, the spatial arrangement of trees is changed. Specifically, topographic normalization vertically condenses and distorts the PAI profile, which consequently alters the distribution pattern of plant area density in space. This effect becomes more evident as the slope increases. Furthermore, topographic normalization may also undermine the complexity (i.e., canopy layer number and entropy) of the PAI profile. The decrease in PAI profile complexity is not solely determined by local topography, but is determined by the interaction between local topography and the spatial distribution of each tree. This research demonstrates that when calculating the PAI profile from airborne LiDAR data, local topography needs to be taken into account. We therefore suggest that for ecological applications, such as vertical forest structure analysis and modeling of biodiversity, topographic normalization should not be applied in non-flat areas when using LiDAR data.

  2. Postprandial triglycerides and blood coagulation.

    Science.gov (United States)

    Silveira, A

    2001-01-01

    Most of our lifetime we spend in the postprandial state. Postprandial triglyceridemia may represent a procoagulant state involving disturbances of both blood coagulation and fibrinolysis, in particular due to elevation of the plasma levels of activated factor VII (VIIa) and plasminogen activator inhibitor (PAI-1). Therefore, disturbances of the hemostatic system might, at least partly, account for by the link between hypertriglyceridemia and coronary heart disease (CHD). Factor VIIa is the first enzyme of the blood coagulation system and serves a priming function for triggering of the clotting cascade. The coagulant activity of factor VII (VIIc, total activity of factor VII in plasma) was identified as an independent predictor of myocardial infarction in initially healthy middle-aged men, and particularly of fatal coronary events, and both serum cholesterol and triglyceride concentrations correlated positively with the VIIc level. Addition of fat to diet has been consistently shown to cause a rapid conversion of the factor VII zymogen into its active form (VIIa) whereas the concentration of total protein is unaffected. Postprandial activation of factor VII is dependent on lipolytic activity and it is mainly supported by large triglyceride-rich lipoprotein of the VLDL class. Studies in vivo with specific coagulation factor-deficient patients indicate that factor IX is essential for the postprandial activation of factor VII. The basal generation of thrombin seems to be unaffected by increased plasma levels of VIIa. However, since VIIa-tissue factor complex is responsible for the initiation of the coagulation cascade, increased generation of VIIa in the postprandial state would increase the potential for thrombin production in the event of plaque rupture. Plasminogen activator inhibitor-1 (PAI-1) is the major physiological inhibitor of the plasminogen activators in the circulation and thereby the principal inhibitor of the fibrinolytic system. Postprandial

  3. Mural Thrombus in the Normal-Appearing Descending Thoracic Aorta of a Chronic Smoker

    Science.gov (United States)

    Habib, Habib; Hsu, Judy; Winchell, Patricia Jo; Daoko, Joseph

    2013-01-01

    Thrombus formation in an atherosclerotic or aneurysmal descending thoracic aorta is a well-described, frequently encountered vascular condition. In comparison, thrombus formation in a normal-appearing descending thoracic aorta is reported far less often. We describe the case of a 46-year-old woman who had splenic and renal infarctions secondary to embolic showers from a large, mobile thrombus in a morphologically normal proximal descending thoracic aorta. After the patient underwent anticoagulation, stent-grafting, and surgical bypass to correct an arterial blockage caused by the stent-graft, she resumed a relatively normal life. In contrast with other cases of a thrombotic but normal-appearing descending thoracic aorta, this patient had no known malignancy or systemic coagulative disorders; her sole risk factor was chronic smoking. We discuss our patient's case and review the relevant medical literature, focusing on the effect of smoking on coagulation physiology. PMID:24391341

  4. Potential Use of Polyaluminium Chloride and Tobacco Leaf as Coagulant and Coagulant Aid in Post-Treatment of Landfill Leachate

    Directory of Open Access Journals (Sweden)

    Nurfarahim Rusdizal

    2015-12-01

    Full Text Available A study was conducted to treat stabilized leachate by applying polyaluminium chloride (PAC and tobacco leaf extract as a coagulant and coagulant aid. Experimental results indicated that the tobacco leaves were positively charged. The removal rate of the chemical oxygen demand, using 1500 mg/L PAC as a sole coagulant, was approximately 63% and increased to 91% when 1000 mg/L PAC was mixed with 1000 mg/L tobacco leaf. Additionally, 1500 mg/L PAC with 250 - 1000 mg/L tobacco leaf and 54% ammoniacal nitrogen was removed, compared with only 46% reduction using 1500 mg/L with only 46% reduction.

  5. Implementation of a microcontroller-based semi-automatic coagulator.

    Science.gov (United States)

    Chan, K; Kirumira, A; Elkateeb, A

    2001-01-01

    The coagulator is an instrument used in hospitals to detect clot formation as a function of time. Generally, these coagulators are very expensive and therefore not affordable by a doctors' office and small clinics. The objective of this project is to design and implement a low cost semi-automatic coagulator (SAC) prototype. The SAC is capable of assaying up to 12 samples and can perform the following tests: prothrombin time (PT), activated partial thromboplastin time (APTT), and PT/APTT combination. The prototype has been tested successfully.

  6. Peculiarities of coagulation hemostasis disorders in patients with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Yakovlieva V.H.

    2015-09-01

    Full Text Available The violation of blood coagulation properties is observed in many diseases of the respiratory system, including chronic obstructive pulmonary disease (COPD. It is known that in a stable COPD phase release of proinflammatory cytokines in blood is observed, it leads to disturbance of hemostasis parameters toward hypercoagulation. The aim of our study was to determine possibility of coagulation disorders formation in patients with COPD in a stable phase of pathological process at different stages of disease course and identify relationship between coagulation parameters levels and degree of violation of ventilation lung function. Materials and methods. We examined 30 patients with COPD in a stable disease phase, included in the main group (FEV1 =49,5±15,5% of the due, there were 27 men (90.0%, 3 (30.0% women, mean age was 61,8±7,9 years, level of pack /years index - 34,2±15,3. The control group consisted of 10 healthy subjects matched with the patients of the main group by age and sex. All patients were divided into 2 subgroups. Subgroup 1 included 16 patients with moderate COPD, that is the level of FEV1>50% (61,8±7,4% of predicted, and subgroup 2 - 14 COPD patients with severe COPD, that is the level of FEV1 <50% (35,3±8,2% of predicted. Patients received standard treatment according to the disease stage. Main indicators of coagulation levels: prothrombin index (PI, prothrombin ratio (PR, international normalized ratio (INR, activated partial thromboplastin time (APTT, thrombin time (TT and antithrombin III (AT III were identified in all patients. Results. The levels of PI, PR and INR in the subgroup 1 differed significantly from those of in the subgroup 2, control group (p<0,05 and pointed at hypercoagulation, whereas in the subgroup 2 all indicators were absolutely identical with control group. Correlation link between the level of INR levels and FEV1 (r=-0,73; p<0.01 in patients of the main group was determined. Levels of APTT, TT and AT

  7. Coagulation mechanism of salt solution-extracted active component in Moringa oleifera seeds.

    Science.gov (United States)

    Okuda, T; Baes, A U; Nishijima, W; Okada, M

    2001-03-01

    This study focuses on the coagulation mechanism by the purified coagulant solution (MOC-SC-PC) with the coagulation active component extracted from M. oleifera seeds using salt solution. The addition of MOC-SC-PC tap water formed insoluble matters. This formation was responsible for kaolin coagulation. On the other hand, insoluble matters were not formed when the MOC-SC-PC was added into distilled water. The formation was affected by Ca2+ or other bivalent cations which may connect each molecule of the active coagulation component in MOC-SC-PC and form a net-like structure. The coagulation mechanism of MOC-SC-PC seemed to be an enmeshment of Kaolin by the insoluble matters with the net-like structure. In case of Ca2+ ion (bivalent cations), at least 0.2 mM was necessary for coagulation at 0.3 mgC l-1 dose of MOC-SC-PC. Other coagulation mechanisms like compression of double layer, interparticle bridging or charge neutralization were not responsible for the coagulation by MOC-SC-PC.

  8. Nitric Oxide, Inflammation, Lipid Profile, and Cortisol in Normal- and Overweight Women With Fibromyalgia.

    Science.gov (United States)

    Rus, Alma; Molina, Francisco; Gassó, Manuela; Camacho, Maria Victoria; Peinado, Maria Ángeles; del Moral, Maria Luisa

    2016-03-01

    Research has identified many factors associated with fibromyalgia (FM), but findings have been inconsistent. This study aimed to investigate changes in levels of nitric oxide (NO), inflammatory markers, lipid profile, and cortisol in normal- and overweight patients with FM and controls. Since most patients with FM are overweight, we explored possible changes in these markers according to body mass index (BMI). This preliminary study was performed on serum samples of women with FM and age-matched controls, grouped according to their BMI: 12 normal-weight patients and 12 controls and 13 overweight patients and 8 controls. Ozone-based chemiluminescence assay was used to measure NO. Inflammatory mediators and cortisol were determined by immunoassay. Lipid profile was measured by a spectrophotometric procedure. Functional capacity was assessed by the fibromyalgia impact questionnaire (FIQ). Normal-weight patients showed higher levels of C-reactive protein (CRP) and apolipoprotein B compared to controls (both p < .05). CRP, apolipoprotein B, and triglycerides were higher in overweight patients versus overweight controls (all p < .05) and in overweight versus normal-weight patients (CRP p < .01; apolipoprotein B, triglycerides p < .05). The other markers were unaffected. Apolipoprotein B (r = .762; p < .05) and NO (r = -.921; p < .05) levels correlated with FIQ score in normal-weight patients. CRP level correlated with FIQ (r = .912; p < .05) in overweight patients. CRP and apolipoprotein B, biomarkers linked to cardiovascular events, may be associated with FM-related dysfunction in normal- and overweight women with FM. Their increased levels in these patients may indicate an increased risk of cardiovascular disease. © The Author(s) 2015.

  9. Infrared coagulation: a new treatment for hemorrhoids

    International Nuclear Information System (INIS)

    Leicester, R.J.; Nicholls, R.J.; Mann, C.V.

    1981-01-01

    Many methods, which have effectively reduced the number of patients requiring hospital admission, have been described for the outpatient treatment of hemorrhoids. However, complications have been reported, and the methods are often associated with unpleasant side effects. In 1977 Neiger et al. described a new method that used infrared coagulation, which produced minimal side effects. The authors have conducted a prospective, randomized trial to evaluate infrared coagulation compared with more traditional methods of treatment. The authors' results show that it may be more effective than injection sclerotherapy in treating non-prolapsing hemorrhoids and that it compares favorably with rubber band ligation in most prolapsing hemorrhoids. No complications occurred, and significantly fewer patients experienced pain after infrared coagulation

  10. Intraventricular hemorrhage in preterm infants: coagulation perspectives.

    Science.gov (United States)

    Kuperman, Amir A; Kenet, Gili; Papadakis, Emmanuel; Brenner, Benjamin

    2011-10-01

    It has long been considered that a severe coagulation deficiency in premature newborns could be a major contributing factor in the occurrence of intraventricular hemorrhage (IVH). High-grade IVH has also been shown to coincide with severe derangement of coagulation in extremely low birth weight infants. This review focuses on the relevance of the physiologically developing immature hemostatic system to IVH, and the potential benefit of agents affecting hemostasis for IVH therapy or prevention in preterm infants. The findings of small, open-label interventional studies on the effect of ethamsylate, vitamin K, fresh frozen plasma, recombinant activated factor VII, and prothrombin complex concentrate on the premature coagulation system will be reviewed. © Thieme Medical Publishers.

  11. Plasma renin activity profile in normal and hypertensive Filipinos

    International Nuclear Information System (INIS)

    Guevara, R.; Torres, J. Jr.; Abundo, H.P.; Perez, A.P.

    To establish a base line profile of plasma renin activity in normotensive and hypertensive Filipinos, 1.019 cases, 479 males and 540 females with an age range 14 - 89 years (mean - 46 + -20) were studied at the Santo Tomas University Hospital of various life styles from the Metro-Manila area, 248 comprised the normotensive group (male - 122 or 49.2 %, female 126 or 50.8 %) and 771 were hypertensive. Of these, 711 (92.6 %) has essential hypertension and are presented in this report. Plasma Renin Activity was determined by radioimmunoassay using Dainabot Renin-Ricket. Concurrent 24 hr. urine sodium and potassium were determined. Nomograms of plasma renin activity as related to urine sodium excretion were drawn after computerized statistical analysis of data. The normal mean value of plasma renin activity was found to be 1.64 + - 0.81 ng./ml./hr. in the upright position and 1.15 + - .68 ng./ml./hr. in the supine position. Based on the nomogram derived, the values obtained in the 711 cases of essential hypertension were classified into High Renin - 14.3 % Normal Renin - 56.1 % and Low Renin - 29.6 %. This study establishes normal levels of plasma renin activity as well as define and classify same renin activity among hypertensive Filipinos, a useful and practicable guide for treatment and can be of prognostic significance. (author)

  12. The Coagulant Type Influence on Removal Efficiency of 5- and 6-Ring Pahs During Water Coagulation Process

    Directory of Open Access Journals (Sweden)

    Nowacka Anna

    2014-12-01

    Full Text Available The article presents results on investigation of the removal efficiency of selected 5- and 6-ring polycyclic aromatic hydrocarbons (benzo[a]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[j]fluoranthene, benzo[g,h,i]perylene, indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene from water during coagulation and sedimentation process. Two pre-hydrolyzed aluminum coagulants: PAX XL 19H and FLOKOR 105V were chosen for research. Process was carried out at optimum process parameters: rapid-mixing - 3 min at the rotational speed of 200 rpm, slow mixing - 10 min at 30 rpm, sedimentation - 60 min. The removal effectiveness was dependant on coagulant type and its composition. Better results in the removal of 5-and 6-ring PAHs were obtained after application of FLOKOR 105V (lower aluminum content than after using PAX XL 19H.

  13. In vitro investigation of the effects of exogenous sugammadex on coagulation in orthopedic surgical patients.

    Science.gov (United States)

    Lee, Il Ok; Kim, Young Sung; Chang, Hae Wone; Kim, Heezoo; Lim, Byung Gun; Lee, Mido

    2018-05-24

    Previous studies have shown that sugammadex resulted in the prolongation of prothrombin time and activated partial thromboplastin time. In this study, we aimed to investigate the in vitro effects of exogenous sugammadex on the coagulation variables of whole blood in healthy patients who underwent orthopedic surgery. The effects of sugammadex on coagulations were assessed using thromboelastography (TEG) in kaolin-activated citrated blood samples taken from 14 healthy patients who underwent orthopedic surgery. The in vitro effects of three different concentrations of sugammadex (42, 193, and 301 μg mL - 1 ) on the TEG profiles were compared with those of the control (0 μg mL - 1 ). Previous studies indicated that these exogenous concentrations correspond to the approximate maximum plasma concentrations achieved after the administration of 4, 16, and 32 mg kg - 1 sugammadex to healthy subjects. Increased sugammadex concentrations were significantly associated with reduced coagulation, as evidenced by increases in reaction time (r), coagulation time, and time to maximum rate of thrombus generation (TMRTG), and decreases in the angle, maximum amplitude, and maximum rate of thrombus generation. Compared with the control, the median percentage change (interquartile range) in the TEG values of the samples treated with the highest exogenous sugammadex concentration was the greatest for r, 53% (26, 67.3%), and TMRTG, 48% (26, 59%). This in vitro study suggests that supratherapeutic doses of exogenous sugammadex might be associated with moderate hypocoagulation in the whole blood of healthy subjects. identifier:  UMIN000029081 , registered 11 September 2017.

  14. Optimum coagulant forecasting by modeling jar test experiments using ANNs

    Science.gov (United States)

    Haghiri, Sadaf; Daghighi, Amin; Moharramzadeh, Sina

    2018-01-01

    Currently, the proper utilization of water treatment plants and optimizing their use is of particular importance. Coagulation and flocculation in water treatment are the common ways through which the use of coagulants leads to instability of particles and the formation of larger and heavier particles, resulting in improvement of sedimentation and filtration processes. Determination of the optimum dose of such a coagulant is of particular significance. A high dose, in addition to adding costs, can cause the sediment to remain in the filtrate, a dangerous condition according to the standards, while a sub-adequate dose of coagulants can result in the reducing the required quality and acceptable performance of the coagulation process. Although jar tests are used for testing coagulants, such experiments face many constraints with respect to evaluating the results produced by sudden changes in input water because of their significant costs, long time requirements, and complex relationships among the many factors (turbidity, temperature, pH, alkalinity, etc.) that can influence the efficiency of coagulant and test results. Modeling can be used to overcome these limitations; in this research study, an artificial neural network (ANN) multi-layer perceptron (MLP) with one hidden layer has been used for modeling the jar test to determine the dosage level of used coagulant in water treatment processes. The data contained in this research have been obtained from the drinking water treatment plant located in Ardabil province in Iran. To evaluate the performance of the model, the mean squared error (MSE) and correlation coefficient (R2) parameters have been used. The obtained values are within an acceptable range that demonstrates the high accuracy of the models with respect to the estimation of water-quality characteristics and the optimal dosages of coagulants; so using these models will allow operators to not only reduce costs and time taken to perform experimental jar tests

  15. Disseminated intravascular coagulation in meningococcal sepsis. Case 7

    NARCIS (Netherlands)

    Zeerleder, S.; Zürcher Zenklusen, R.; Hack, C. E.; Wuillemin, W. A.

    2003-01-01

    We report on a man (age: 49 years), who died from severe meningococcal sepsis with disseminated intravascular coagulation (DIC), multiple organ dysfunction syndrome and extended skin necrosis. We discuss in detail the pathophysiology of the activation of coagulation and fibrinolysis during sepsis.

  16. Interplay between coagulation and vascular inflammation in sickle cell disease

    Science.gov (United States)

    Sparkenbaugh, Erica; Pawlinski, Rafal

    2013-01-01

    Sickle cell disease is the most common inherited hematologic disorder that leads to the irreversible damage of multiple organs. Although sickling of red blood cells and vaso-occlusion are central to the pathophysiology of sickle cell disease the importance of hemolytic anemia and vasculopathy has been recently recognized. Hypercoagulation state is another prominent feature of sickle cell disease and is mediated by activation of both intrinsic and extrinsic coagulation pathways. Growing evidence demonstrates that coagulation may not only contribute to the thrombotic complications, but also to vascular inflammation associated with this disease. This article summarizes the role of vascular inflammation and coagulation activation, discusses potential mechanisms responsible for activation of coagulation and reviews recent data demonstrating the crosstalk between coagulation and vascular inflammation in sickle cell disease. PMID:23593937

  17. Colloids removal from water resources using natural coagulant: Acacia auriculiformis

    Science.gov (United States)

    Abdullah, M.; Roslan, A.; Kamarulzaman, M. F. H.; Erat, M. M.

    2017-09-01

    All waters, especially surface waters contain dissolved, suspended particles and/or inorganic matter, as well as several biological organisms, such as bacteria, algae or viruses. This material must be removed because it can affect the water quality that can cause turbidity and colour. The objective of this study is to develop water treatment process from Seri Alam (Johor, Malaysia) lake water resources by using natural coagulant Acacia auriculiformis pods through a jar test experiment. Jar test is designed to show the effectiveness of the water treatment. This process is a laboratory procedure that will simulate coagulation/flocculation with several parameters selected namely contact time, coagulant dosage and agitation speed. The most optimum percentage of colloids removal for each parameter is determined at 0.2 g, 90 min and 80 rpm. FESEM (Field-emission Scanning Electron Microscope) observed the small structures of final floc particles for optimum parameter in this study to show that the colloids coagulated the coagulant. All result showed that the Acacia auriculiformis pods can be a very efficient coagulant in removing colloids from water.

  18. Tissue Factor Coagulant Activity is Regulated by the Plasma Membrane Microenvironment.

    Science.gov (United States)

    Yu, Yuanjie; Böing, Anita N; Hau, Chi M; Hajji, Najat; Ruf, Wolfram; Sturk, Auguste; Nieuwland, Rienk

    2018-06-01

     Tissue factor (TF) can be present in a non-coagulant and coagulant form. Whether the coagulant activity is affected by the plasma membrane microenvironment is unexplored.  This article studies the presence and coagulant activity of human TF in plasma membrane micro-domains.  Plasma membranes were isolated from human MIA PaCa2 cells, MDA-MB-231 cells and human vascular smooth muscle cells by Percoll gradient ultracentrifugation after cell disruption. Plasma membranes were fractionated by OptiPrep gradient ultracentrifugation, and the presence of TF, flotillin, caveolin, clathrin, protein disulphide isomerase (PDI), TF pathway inhibitor (TFPI) and phosphatidylserine (PS) were determined.  Plasma membranes contain two detergent-resistant membrane (DRM) compartments differing in density and biochemical composition. High-density DRMs (DRM-H) have a density ( ρ ) of 1.15 to 1.20 g/mL and contain clathrin, whereas low-density DRMs (DRM-L) have a density between 1.09 and 1.13 g/mL and do not contain clathrin. Both DRMs contain TF, flotillin and caveolin. PDI is detectable in DRM-H, TFPI is not detectable in either DMR-H or DRM-L and PS is detectable in DRM-L. The DRM-H-associated TF (> 95% of the TF antigen) lacks detectable coagulant activity, whereas the DRM-L-associated TF triggers coagulation. This coagulant activity is inhibited by lactadherin and thus PS-dependent, but seemed insensitive to 16F16, an inhibitor of PDI.  Non-coagulant and coagulant TF are present within different types of DRMs in the plasma membrane, and the composition of these DRMs may affect the TF coagulant activity. Schattauer GmbH Stuttgart.

  19. Correlation between thromboelastography and traditional coagulation test parameters in hospitalized dogs

    Directory of Open Access Journals (Sweden)

    Rubanick JV

    2017-02-01

    Full Text Available Jean V Rubanick, Medora B Pashmakova, Micah A Bishop, James W Barr Department of Veterinary Small Animal Clinical Sciences, Texas A&M University, College Station, TX, USA Abstract: A hospital-based, prospective cross-sectional study was used to compare kaolin-activated thromboelastography (TEG parameters with traditional coagulation tests in 29 hospitalized dogs. Cases were included if the attending clinician requested coagulation testing. Blood was obtained from each dog and coagulation (prothrombin time, partial thromboplastin time, antithrombin activity, d-dimer concentration, and fibrinogen concentration and TEG analyses were performed. Hematocrit (Hct was also measured. Traditional coagulation results were evaluated for correlation with those from kaolin-activated TEG. Spearman’s correlation was used to calculate correlation coefficients. Fibrinogen was positively correlated with maximum amplitude (Pearson r=0.72, P<0.001 and global clot strength (Pearson r=0.72, P<0.001. There was no correlation between any of the remaining coagulation variables, TEG parameters, or Hct. Results of kaolin-activated TEG and traditional coagulation tests are not interchangeable means of monitoring coagulation derangements in this intensive care unit patient population. Determination of a true outcome measure is necessary to establish TEG’s clinical relevance to veterinary medicine. Keywords: TEG, thromboelastography, coagulation, hemostasis

  20. Enhanced Coagulation-Flocculation Performance of Iron-Based Coagulants: Effects of PO4(3-) and SiO3(2-) Modifiers.

    Science.gov (United States)

    Chen, Wei; Zheng, Huaili; Teng, Houkai; Wang, Yili; Zhang, Yuxin; Zhao, Chuanliang; Liao, Yong

    2015-01-01

    PO4(3-) and SiO3(2-) are often used as modifier to improve stability and aggregating ability of the iron-base coagulants, however, there are few reports about their detailed comparison between the coagulation performance and mechanisms. In this study, three coagulants--polyferric phosphoric sulfate (PFPS), polysilicon ferric sulfate (PFSS), and polyferric sulfate (PFS) were synthesized; their structure and morphology were characterized by Fourier transformed infrared (FT-IR) spectroscopy, X-ray diffraction (XRD) and Scanning electron microscope (SEM). Alkali titration and Ferron species analysis were employed to investigate the hydrolysis performance and species distribution. Jar test was conducted to measure their coagulation behaviors at different dosage, pH, and temperatures in which the flocs properties were measured. The results showed that a number of new compounds were formed due to the presence of PO4(3-) and SiO3(2-). Moreover, PFPS and PFSS had similar level in Fea as well as Feb. Among them, PFPS produced more multi-core iron atoms polymer and content of Feb, and the formed flocs were larger and denser. It exhibited superior coagulation performance in terms of turbidity reduction, UV254 removal and residual ferric concentration. Jar test and floc breakage/regrowth experiments indicated other than charge neutrality, the dominated mechanism involved in PFSS was the adsorption between polysilicic acid and solution particle, while PFPS was sweeping, entrapment/adsorption resulting from larger polymer colloid of Fe-P chemistry bond.

  1. Enhanced Coagulation-Flocculation Performance of Iron-Based Coagulants: Effects of PO4(3- and SiO3(2- Modifiers.

    Directory of Open Access Journals (Sweden)

    Wei Chen

    Full Text Available PO4(3- and SiO3(2- are often used as modifier to improve stability and aggregating ability of the iron-base coagulants, however, there are few reports about their detailed comparison between the coagulation performance and mechanisms. In this study, three coagulants--polyferric phosphoric sulfate (PFPS, polysilicon ferric sulfate (PFSS, and polyferric sulfate (PFS were synthesized; their structure and morphology were characterized by Fourier transformed infrared (FT-IR spectroscopy, X-ray diffraction (XRD and Scanning electron microscope (SEM. Alkali titration and Ferron species analysis were employed to investigate the hydrolysis performance and species distribution. Jar test was conducted to measure their coagulation behaviors at different dosage, pH, and temperatures in which the flocs properties were measured. The results showed that a number of new compounds were formed due to the presence of PO4(3- and SiO3(2-. Moreover, PFPS and PFSS had similar level in Fea as well as Feb. Among them, PFPS produced more multi-core iron atoms polymer and content of Feb, and the formed flocs were larger and denser. It exhibited superior coagulation performance in terms of turbidity reduction, UV254 removal and residual ferric concentration. Jar test and floc breakage/regrowth experiments indicated other than charge neutrality, the dominated mechanism involved in PFSS was the adsorption between polysilicic acid and solution particle, while PFPS was sweeping, entrapment/adsorption resulting from larger polymer colloid of Fe-P chemistry bond.

  2. Characterization of coagulation factor synthesis in nine human primary cell types

    NARCIS (Netherlands)

    Dashty, Monireh; Akbarkhanzadeh, Vishtaseb; Zeebregts, Clark J.; Spek, C. Arnold; Sijbrands, Eric J.; Peppelenbosch, Maikel P.; Rezaee, Farhad

    2012-01-01

    The coagulation/fibrinolysis system is essential for wound healing after vascular injury. According to the standard paradigm, the synthesis of most coagulation factors is restricted to liver, platelets and endothelium. We challenged this interpretation by measuring coagulation factors in nine human

  3. Treatment of sugar beet thick juice spent wash by chemical and natural coagulants

    Directory of Open Access Journals (Sweden)

    Antov Mirjana G.

    2009-01-01

    Full Text Available The possibility of treatment of wastewater from bioethanol production by aluminium sulfate and natural coagulant extracted from common bean seed was studied. The highest coagulation activity at pH 6.5 is reached with analum dose of 1 g/l, but only a little lower coagulation activities were obtained by the dose of 0.05 and 0.10 g/l, which is more favorable for economic and environmental reasons. When natural coagulant from common bean was applied the highest coagulation activity, 14.3%, at pH 6.5 is reached with a dose of 0.5 ml/l. However, when common bean natural coagulant was used simultaneously with alum, the highest turbidity removal resulting in 24% coagulation activity was achieved and this was more efficient than when alum or natural coagulant were used.

  4. Coagulation management in patients undergoing neurosurgical procedures.

    Science.gov (United States)

    Robba, Chiara; Bertuetti, Rita; Rasulo, Frank; Bertuccio, Alessando; Matta, Basil

    2017-10-01

    Management of coagulation in neurosurgical procedures is challenging. In this contest, it is imperative to avoid further intracranial bleeding. Perioperative bleeding can be associated with a number of factors, including anticoagulant drugs and coagulation status but is also linked to the characteristic and the site of the intracranial disorder. The aim of this review will be to focus primarily on the new evidence regarding the management of coagulation in patients undergoing craniotomy for neurosurgical procedures. Antihemostatic and anticoagulant drugs have shown to be associated with perioperative bleeding. On the other hand, an increased risk of venous thromboembolism and hypercoagulative state after elective and emergency neurosurgery, in particular after brain tumor surgery, has been described in several patients. To balance the risk between thrombosis and bleeding, it is important to be familiar with the perioperative changes in coagulation and with the recent management guidelines for anticoagulated patients undergoing neurosurgical procedures, in particular for those taking new direct anticoagulants. We have considered the current clinical trials and literature regarding both safety and efficacy of deep venous thrombosis prophylaxis in the neurosurgical population. These were mainly trials concerning both elective surgical and intensive care patients with a poor grade intracranial bleed or multiple traumas with an associated severe traumatic brain injury (TBI). Coagulation management remains a major issue in patients undergoing neurosurgical procedures. However, in this field of research, literature quality is poor and further studies are necessary to identify the best strategies to minimize risks in this group of patients.

  5. Treatment of phosphate-containing oily wastewater by coagulation and microfiltration.

    Science.gov (United States)

    Zhang, Jin; Sun, Yu-xin; Huang, Zhi-feng; Liu, Xing-qin; Meng, Guang-yao

    2006-01-01

    The oily wastewater generated from pretreatment unit of electrocoating industry contains oils, phosphate, organic solvents, and surfactants. In order to improve the removal efficiencies of phosphate and oils, to mitigate the membrane fouling, coagulation for ceramic membrane microfiltration of oily wastewater was performed. The results of filtration tests show that the membrane fouling decreased and the permeate flux and quality increased with coagulation as pretreatment. At the coagulant Ca (OH)2 dosage of 900 mg/L, the removal efficiency of phosphate was increased from 46.4% without coagulation to 99.6%; the removal of COD and oils were 97.0% and 99.8%, respectively. And the permeate flux was about 70% greater than that when Ca(OH)2 was not used. The permeate obtained from coagulation and microfiltration can be reused as make-up water, and the recommended operation conditions for pilot and industrial application are transmembrane pressure of 0.10 MPa and cross-flow velocity of 5 m/s. The comparison results show that 0.2 microm ZrO2 microfilter with coagulation could be used to perform the filtration rather than conventional ultrafilter, with very substantial gain in flux and removal efficiency of phosphate.

  6. The prospects of application of natural antioxidants in correction of blood coagulation in patients with breast cancer during radiation therapy

    International Nuclear Information System (INIS)

    Syimonova, L.Yi.; Byilogurova, L.V.; Gertman, V.Z.; Pushkar, S.M.; Muzikant, P.M.; Nesterenko, G.Yi.

    2008-01-01

    As an accompanying therapy of the patients with BC Bipolan produced positive effect on coagulation homeostasis. By the end of the course of treatment the indices of homeostasis normalized in the experimental group of the patients; manifestations of DIC syndrome and thromboembolic complications were controlled

  7. IMPROVEMENT OF COAGULATION PROCESS FOR THE PRUT RIVER WATER TREATMENT USING ALUMINUM SULPHATE

    Directory of Open Access Journals (Sweden)

    Larisa Postolachi

    2015-06-01

    Full Text Available The aim of presented research was to optimize the treatment process of the Prut River water. In order to realize the proposed goal, there were studied the following factors which can improve the process of coagulation: (i the influence of stirring speed during coagulation and (ii the influence of the concentration of the coagulant solution added in the process of coagulation. The optimal conditions of coagulation were established using the Jar-test method. Application of the recommended procedure contribute to the reduction of the coagulant dose, the contact time, the aluminum concentration in water and the expenses for water treatment.

  8. Disseminated intravascular coagulation (DIC)

    Science.gov (United States)

    ... Jr, Silberstein LE, et al, eds. Hematology: Basic Principles and Practice . 6th ed. Philadelphia, PA: Elsevier Saunders; 2013:chap 141. Thachil J, Toh CH. Current concepts in the management of disseminated intravascular coagulation. Thromb Res . 2012;129 ...

  9. Vitamin K: from coagulation to calcification.

    Science.gov (United States)

    Paakkari, Ilari

    Vitamin K is not only essential for the synthesis of coagulation factors in the liver, but it also strengthens the bones and prevents calcification of the arteries. These effects are mediated through the same mechanism, i.e. carboxylation of Gla target proteins. The discovery of novel Gla proteins that are not associated with blood coagulation or calcium metabolism indicates that vitamin K has additional effects in the pancreas and the central nervous system, for example. As dietary supplements, vitamin K1 of plant origin and vitamins K2 of bacterial origin may exert different effects.

  10. WATER PURIFICATION BY COAGULATION UNDER THE INFLUENCE OF ULTRASONIC FIELD

    Directory of Open Access Journals (Sweden)

    Vikulina Vera Borisovna

    2016-03-01

    Full Text Available The authors carried out experiments on the in-fluence of ultrasound on the subsidence of suspended materials. The efficiency of coagulation process in wa-ter purification in ultrasound field is estimated. The influence of ultrasound on the water with suspended materials before introducing coagulant was a condition of the experiment. The magnetostriction method for obtaining ultrasound oscillations with the help of ultra-sound generator of batch production was applied. The samples were chosen and the coagulation process was controlled using standard procedures. The experimental data was obtained which estimate the efficiency in-crease in the subsidence of suspended materials de-pending on the duration of ultrasound processing. Dur-ing one minute of ultrasound processing the following results were obtained: the subsidence efficiency in-creased by 25.83 % in case of coagulant share Al2O3 2.5 mg/l; the subsidence efficiency increased by 23.70 % in case of coagulant share Al2O3 5.0 mg/l.

  11. Coagulation and flocculation of dissolved organic substances with organic polymers

    OpenAIRE

    Kvinnesland, Thomas

    2002-01-01

    Coagulation of natural organic matter (NOM) in water is a well-established process, enabling or enhancing the removal of these substances by different particle separation processes. The dominating coagulating agents used are, however, inorganic salts of iron (Fe3+) and aluminium (Al3+). The primary use of organic polymers is as flocculating agents for already coagulated aggregates. However, in recent years the use of cationic organic polymers have received increasing attent...

  12. Hematometra secondary to anticoagulant rodenticide toxicity

    International Nuclear Information System (INIS)

    Padgett, S.L.; Stokes, J.E.; Tucker, R.L.; Wheaton, L.G.

    1998-01-01

    An adult, intact female Australian shepherd presented for frank vaginal bleeding of unknown duration. The only coagulation profile abnormality upon presentation was mild prolongation of the partial thromboplastin time (PTT). The uterus was removed at surgery and contained a large amount of coagulated blood. Clotting profiles were markedly abnormal48 hours postoperatively. Serum analysis was positive for brodifacoum, an anticoagulant rodenticide. Preoperative coagulation was most likely normalized by vitamin K-1 therapy administered prior to presentation. The only manifestation of anticoagulant rodenticide was hematometra. Rodenticide intoxication should be considered in the differential diagnosis list of hematometra or metrorrhagia

  13. The performance of double layer structure membrane prepared from flowing coagulant

    Science.gov (United States)

    Mieow Kee, Chan; Xeng, Anthony Leong Chan; Regal, Sasiskala; Singh, Balvinder; Raoo, Preeshaath; Koon Eu, Yap; Sok Choo, Ng

    2017-12-01

    Membrane with double layer structure is favourable as it exhibits smooth surface and macrovoids free structure. However, its’ performance in terms of permeability, porosity and strength has not been studied thoroughly. Additionally, the effect of flowing coagulant on the formation of double layer membrane has not been reported. Thus, the objective of this study is to investigate the performance of double layer membranes, which were prepared using flowing coagulant. Results showed that when the coagulant flow changed from laminar to turbulent, the pure water permeation of the membrane increased. It was due to the higher porosity in the membrane, which prepared by turbulent flow (CA-Turbulent) compared to the membrane which fabricated under laminar condition (CA-Laminar). This can be explained by the rapid solvent-coagulant exchange rate between the polymer solution and the turbulent coagulant. In term of strength, the tensile strength of the CA-Turbulent was ~32 MPa, which was 100% higher compared to CA-Laminar. This may due to the presence of large amount of nodules on its surface, which reduced the surface integrity. In conclusion, flowing coagulant altered the membrane properties and adopting turbulent coagulant flow in membrane fabrication would improve the porosity, surface roughness and the strength of the membrane.

  14. Coagulation and Adsorption Treatment of Printing Ink Wastewater

    Directory of Open Access Journals (Sweden)

    Maja Klančnik

    2015-03-01

    Full Text Available The intention of the study was to improve the efficiency of total organic carbon (TOC and colour removal from the wastewater samples polluted with flexographic printing ink following coagulation treatments with further adsorption onto activated carbons and ground orange peel. The treatment efficiencies were compared to those of further flocculation treatments and of coagulation and adsorption processes individually. Coagulation was a relatively effective single-treatment method, removing 99.7% of the colour and 86.9% of the organic substances (TOC from the printing ink wastewater samples. Further flocculation did not further eliminate organic pollutants, whereas subsequent adsorption with 7 g/l of granular activated carbon further reduced organic substances by 35.1%, and adsorption with 7 g/l of powdered activated carbon further reduced organic substances by 59.3%. Orange peel was an inappropriate adsorbent for wastewater samples with low amounts of pollution, such as water that had been treated by coagulation. However, in highly polluted printing ink wastewater samples, the adsorption treatment with ground orange peel achieved efficiencies comparable to those of the granular activated carbon treatments.

  15. Multivariate relationships between international normalized ratio and vitamin K-dependent coagulation-derived parameters in normal healthy donors and oral anticoagulant therapy patients

    Directory of Open Access Journals (Sweden)

    Golanski Jacek

    2003-11-01

    Full Text Available Abstract Background and objectives International Normalized Ratio (INR is a world-wide routinely used factor in the monitoring of oral anticoagulation treatment (OAT. However, it was reported that other factors, e. g. factor II, may even better reflect therapeutic efficacy of OAT and, therefore, may be potentialy useful for OAT monitoring. The primary purpose of this study was to characterize the associations of INR with other vitamin K-dependent plasma proteins in a heterogenous group of individuals, including healthy donors, patients on OAT and patients not receiving OAT. The study aimed also at establishing the influence of co-morbid conditions (incl. accompanying diseases and co-medications (incl. different intensity of OAT on INR. Design and Methods Two hundred and three subjects were involved in the study. Of these, 35 were normal healthy donors (group I, 73 were patients on medication different than OAT (group II and 95 were patients on stable oral anticoagulant (acenocoumarol therapy lasting for at least half a year prior to the study. The values of INR and activated partial thromboplastin time (APTT ratio, as well as activities of FII, FVII, FX, protein C, and concentration of prothrombin F1+2 fragments and fibrinogen were obtained for all subjects. In statistical evaluation, the uni- and multivariate analyses were employed and the regression equations describing the obtained associations were estimated. Results Of the studied parameters, three (factors II, VII and X appeared as very strong modulators of INR, protein C and prothrombin fragments F1+2 had moderate influence, whereas both APTT ratio and fibrinogen had no significant impact on INR variability. Due to collinearity and low tolerance of independent variables included in the multiple regression models, we routinely employed a ridge multiple regression model which compromises the minimal number of independent variables with the maximal overall determination coefficient. The best

  16. Novel approaches to the management of disseminated intravascular coagulation

    NARCIS (Netherlands)

    Levi, M. [=Marcel M.; de Jonge, E.; van der Poll, T.; ten Cate, H.

    2000-01-01

    Disseminated intravascular coagulation (DIC) is a syndrome characterized by systemic intravascular activation of coagulation, leading to widespread deposition of fibrin in the circulation. We addressed the issue of whether there is evidence that this fibrin deposition contributes to multiple organ

  17. Quality of oral anticoagulation with phenprocoumon in regular medical care and its potential for improvement in a telemedicine-based coagulation service--results from the prospective, multi-center, observational cohort study thrombEVAL.

    Science.gov (United States)

    Prochaska, Jürgen H; Göbel, Sebastian; Keller, Karsten; Coldewey, Meike; Ullmann, Alexander; Lamparter, Heidrun; Jünger, Claus; Al-Bayati, Zaid; Baer, Christina; Walter, Ulrich; Bickel, Christoph; ten Cate, Hugo; Münzel, Thomas; Wild, Philipp S

    2015-01-23

    The majority of studies on quality of oral anticoagulation (OAC) therapy with vitamin K-antagonists are performed with short-acting warfarin. Data on long-acting phenprocoumon, which is frequently used in Europe for OAC therapy and is considered to enable more stable therapy adjustment, are scarce. In this study, we aimed to assess quality of OAC therapy with phenprocoumon in regular medical care and to evaluate its potential for optimization in a telemedicine-based coagulation service. In the prospective observational cohort study program thrombEVAL we investigated 2,011 patients from regular medical care in a multi-center cohort study and 760 patients from a telemedicine-based coagulation service in a single-center cohort study. Data were obtained from self-reported data, computer-assisted personal interviews, and laboratory measurements according to standard operating procedures with detailed quality control. Time in therapeutic range (TTR) was calculated by linear interpolation method to assess quality of OAC therapy. Study monitoring was carried out by an independent institution. Overall, 15,377 treatment years and 48,955 international normalized ratio (INR) measurements were analyzed. Quality of anticoagulation, as measured by median TTR, was 66.3% (interquartile range (IQR) 47.8/81.9) in regular medical care and 75.5% (IQR 64.2/84.4) in the coagulation service (P service with TTR at 76.2% [(IQR 65.6/84.7); P = 0.001)]. Prospective follow-up of coagulation service patients with pretreatment in regular medical care showed an improvement of the TTR from 66.2% (IQR 49.0/83.6) to 74.5% (IQR 62.9/84.2; P service. Treatment in the coagulation service contributed to an optimization of the profile of time outside therapeutic range, a 2.2-fold increase of stabile INR adjustment and a significant decrease in TTR variability by 36% (P Quality of anticoagulation with phenprocoumon was comparably high in this real-world sample of regular medical care. Treatment in a

  18. A Pontential Agriculture Waste Material as Coagulant Aid: Cassava Peel

    Science.gov (United States)

    Othman, N.; Abd-Rahim, N.-S.; Tuan-Besar, S.-N.-F.; Mohd-Asharuddin, S.; Kumar, V.

    2018-02-01

    All A large amount of cassava peel waste is generated annually by small and medium scale industries. This has led to a new policy of complete utilization of raw materials so that there will be little or no residue left that could pose pollution problems. Conversion of these by-products into a material that poses an ability to remove toxic pollutant would increase the market value and ultimately benefits the producers. This study investigated the characteristics of cassava peel as a coagulant aid material and optimization process using the cassava peel was explored through coagulation and flocculation. This research had highlighted that the Cassava peels contain sugars in the form of polysaccharides such as starch and holocellulose. The FTIR results revealed that amino acids containing abundant of carboxyl, hydroxyl and amino groups which has significant capabilities in removing pollutants. Whereas analysis by XRF spectrometry indicated that the CP samples contain Fe2O3 and Al2O3 which might contribute to its coagulation ability. The optimum condition allowed Cassava peel and alum removed high turbidity up to 90. This natural coagulant from cassava peel is found to be an alternative coagulant aid to reduce the usage of chemical coagulants

  19. Evaluation of Impact of Coagulant Type on Operation Parameters in Direct Filtration

    Directory of Open Access Journals (Sweden)

    Ali Torabian

    2007-06-01

    Full Text Available Numerous advantages have been reported on PAC (poly aluminum chloride used as a coagulant over other coagulants such as alum and ferric chloride used in conventional water treatment process with medium and high turbidity levels. These include lower amounts of PACL required specially in removing turbidity, larger floc grain formation, reduced floc sedimentation time, lower sludge production, and relaxation of the need for pH adjustment by lime, among others. The present study aims to evaluate the effects of different coagulants such as ferric chloride and PACL on direct filtration and to identify the most effective material based on both turbidity and particle removal efficiencies. A perfectly experimental pilot system, including raw water preparation, coagulation, flocculation, distribution measurement, and filtration units, was designed and used. Raw water turbidity level in the experimental pilot was below 10 NTU. The effects of various parameters such as coagulant type, filtration rate, and coagulant dosage on the performance of the filter were investigated. The results obtained from several filtration cycles under different conditions indicated that average effluent turbidity level, effluent particle numbers, effluent turbidity variation graph, and effluent particle graph were lower throughout the filtration cycle when PACL was used compared to when ferric chloride was used as the coagulant. Increasing filtration rate led to increased turbidity and particle number. Addition of 2 mg/l of PACL (poor coagulation and flocculation scenario was compared with addition of 5 mg/l of ferric chloride (strong coagulation and flocculation scenario. The results indicated that higher average values of turbidity removal but lower turbidity and particle removal efficiencies obtained in the case of the poor coagulation and flocculation scenario.

  20. Effect of flomoxef on blood coagulation and alcohol metabolism.

    Science.gov (United States)

    Uchida, K; Matsubara, T

    1991-01-01

    The effect of flomoxef, a newly developed oxacephem antibiotic with an N-hydroxyethyltetrazolethiol (HTT) side chain, on blood coagulation and alcohol metabolism was compared with that of a series of cephalosporin antibiotics with N-methyltetrazolethiol (NMTT), thiadiazolethiol (TDT) or methylthiadiazolethiol (MTDT) side chains in position 3' of the cephalosporin nucleus known to cause hypoprothrombinemia and bleeding in patients who are malnourished, debilitated and/or of high age. A disulfiram-like effect caused by inhibition of aldehyde dehydrogenase was observed for NMTT-containing antibiotics. Studies were carried out on healthy volunteers and on rats. Eight-day treatment with 2 g flomoxef i.v. once or twice daily in five and six healthy male volunteers, respectively, did not cause any significant changes in prothrombin time (PT), coagulation factors II, VII, IX or X, in hepaplastin values or fibrinogen levels, activated partial thromboplastin time (APTT), platelet counts, bleeding time, or collagen- and ADP-induced platelet aggregation. Inhibition of vitamin K epoxide reductase was observed in rats treated with flomoxef, yet to a much lesser extent than observed for cephalosporins with NMTT, TDT or MTDT side chains. This defect was quickly normalized by vitamin K injection. There were no differences between oxacephem (1-O) and cephem (1-S) compounds with respect to effects on blood clotting and platelet aggregation. Flomoxef and its side chain HTT showed no influence on alcohol metbolism.

  1. Treatment of sugar beet extraction juice stillage by natural coagulants extracted from common bean

    Directory of Open Access Journals (Sweden)

    Prodanović Jelena M.

    2015-01-01

    Full Text Available Distillery wastewaters have a great pollution potential, and pollution caused by them is one of the most critical environmental issues. This study is concerned with the coagulation efficiency of a new, environmental friendly, natural coagulant extracted from common bean seeds in the primary treatment of distillery wastewater in the bioethanol production from sugar beet juice. Active coagulation components were extracted from ground seeds of common bean with 0.5 mol/L NaCl. The obtained raw extract was used as a coagulant. The coagulation efficiency was measured by jar test at different pH values of wastewater, and a decrease in organic matter content was determined. The experiments confirmed that natural coagulant from common bean could be successfully used for the treatment of extraction juice distillery wastewater. The highest coagulation efficiencies were achieved at the pH 5.2 with a coagulant dose of 30 mL/L, and at the pH 8.5 with a coagulant dose of 5 mL/L, and they were 64.71% and 68.75% respectively. These encouraging results indicate that natural coagulant from common bean seeds is a potential alternative to conventional chemical coagulant/flocculant agents for treatment of wastewaters.[Projekat Ministarstva nauke Republike Srbije, br. III 43005

  2. Operating Conditions of Coagulation-Flocculation Process for High Turbidity Ceramic Wastewater

    Directory of Open Access Journals (Sweden)

    Sameer Al-Asheh

    2017-04-01

    Full Text Available This work attempted to determine the optimum conditions required for the coagulation and flocculation process as an essential stage of the ceramic wastewater treatment. Coagulation and flocculation is a very necessary step in industries as it lessens turbidity, color, and odor of wastewater. The experimental work was performed in several runs. The volume of wastewater used in each run was 200 mL and was kept at this value throughout. In certain runs, the speed of the mixer was varied while keeping the quantity of coagulant and flocculant constant in order to determine the optimum speed that resulted in the least turbidity. A speed of 5% was chosen as the ideal process speed according to the results obtained. Next, experiments were operated at this optimum speed while changing the dosage of coagulant and flocculant in order to decide the optimum dosage. Coagulant and flocculent amounts of 0.4 g (without booster and 0.2 g (with booster selected after the readings were taken. For all the readings, a turbidity meter was used providing results in Nephelometric Turbidity Units (NTU. Lowest turbidity was achieved when using 5% speed with 0.4 grams of coagulant and 0.4 grams of flocculant, or 5% speed with 0.2 grams of coagulant, 0.2 grams of flocculant and 0.25 g/L of booster coagulant. According to factorial design analysis, such as parameters as impeller speed and dosage have an influential impact on the turbidity; while the booster has insignificant influence and other interactions between parameters are important.

  3. Vaginal lactobacilli profile in pregnant women with normal & abnormal vaginal flora.

    Science.gov (United States)

    Yeruva, Thirupathaiah; Rajkumar, Hemalatha; Donugama, Vasundhara

    2017-10-01

    Lactobacilli species that are better adapted to vaginal environment of women may colonize better and offer protection against vaginal pathogenic bacteria. In this study, the distribution of common Lactobacillus species was investigated in pregnant women. Sixty seven pregnant women were included in the study and vaginal samples were collected for Gram staining. Women were classified as normal vaginal flora, intermediate flora and bacterial vaginosis (BV) based on Nugent's score. Vaginal samples were also collected for the identification of Lactobacillus spp. by multiplex polymerase chain reaction (PCR) profiling of 16S rDNA amplification method. Lactobacillus crispatus (100%) was the most predominant Lactobacillus spp. present in pregnant women with normal flora, followed by L. iners (77%), L. jensenii (74%) and L. helveticus (60%). While, L. iners was commonly present across groups in women with normal, intermediate or BV flora, L. crispatus, L. jensenii and L. helveticus decreased significantly as the vaginal flora changed to intermediate and BV. In women with BV, except L. iners other species of lactobacilli was less frequently prevalent. Species such as L. rhamnosus, L. fermentum, L. paracasei and L. casei were not detected in any vaginal sample. L. crispatus, L. jensinii and L. helveticus were predominant species in women with normal flora. L. crispatus alone or in combination with L. jensinii and L. helveticus may be evaluated for probiotic properties for the prevention and treatment of BV.

  4. Treatment of sugar beet thick juice spent wash by chemical and natural coagulants

    OpenAIRE

    Antov Mirjana G.; Klašnja Mile T.; Šćiban Marina B.

    2009-01-01

    The possibility of treatment of wastewater from bioethanol production by aluminium sulfate and natural coagulant extracted from common bean seed was studied. The highest coagulation activity at pH 6.5 is reached with analum dose of 1 g/l, but only a little lower coagulation activities were obtained by the dose of 0.05 and 0.10 g/l, which is more favorable for economic and environmental reasons. When natural coagulant from common bean was applied the highest coagulation activity, 14.3%, at pH ...

  5. Coagulation sensors based on magnetostrictive delay lines for biomedical and chemical engineering applications

    International Nuclear Information System (INIS)

    Maliaritsi, E.; Zoumpoulakis, L.; Simitzis, J.; Vassiliou, P.; Hristoforou, E.

    2006-01-01

    Coagulation sensors based on the magnetostrictive delay line technique are presented in this paper. They are based on magnetostrictive ribbons and are used for measuring the coagulation, curing or solidification time of different liquids. Experimental results indicate that the presented sensing elements can determine the blood coagulation with remarkable repeatability, thus allowing their use as blood coagulation sensors. Additionally, results indicate that they can also measure curing time of resins, solidification of fluids and coagulation of chemical substances, therefore allowing their implementation in chemical engineering applications

  6. Superiority of ferric chloride as coagulant over alum and ferrous sulphate at controlled pH and cost comparison of these coagulant

    International Nuclear Information System (INIS)

    Irfan, M.

    2008-01-01

    This study was conducted by author as a member of Specialty Chemical Division of Sitara Chemical Industries which is the largest chlor -alkali manufacturing industry in Pakistan. Sitara is also producing FeCl/sub 3/ as a byproduct to consume its additional quantity of chlorine produced during electrolysis of brine solution for caustic soda preparation. Most of the industries are using Alum along with other polymers for treatment of effluent waste water. Treatment system is based on sand bed filters. For coagulation of unwanted materials present in the water, Alum is being used with Anionic Polymer (Accofloc-A2125) as flocculent. But the ferric chloride is not only functions as a reactants to remove water impurities but it also functions as a both coagulant and a Flocculent. This study was conducted for finding best alternative chemicals to improve treated water quality. For this purpose Ferric Chloride (FeCl/sub 3/) is used as best alternative of alum for better removal of turbidity, heavy metals and micro organisms to eradicate above said problems and for better removal of turbidity, heavy metals and micro, organisms to eradicate health problems. As per lab scale results quality of treated water with Ferric Chloride (FeCl/sub 3/) proved better than that of Alum. The main objective of this research is to investigate the efficiency of coagulation and flocculation processes for removing suspended solids, colour and COD which present in significant quantity. Three types of coagulants were examined using standard jar test apparatus, i.e., aluminum sulphate (alum), ferric chloride (FeCl/sub 3/) and ferrous sulphate (FeSO/sub 4/). The effects of agitation speed, settling time, pH, coagulant dosages and temperature were examined. At 300 rpm of rapid mixing and 50 rpm of slow mixing and 60 minutes settling time, higher removals of suspended solids (over 95%), colour (90%) and COD (43%) were achieved at pH 4 and 12. FeCl/sub 3/ was found to be superior compared with other

  7. Using Coagulation Process in Optimizing Natural Organic Matter Removal from Low Turbidity Waters

    Directory of Open Access Journals (Sweden)

    Alireza Mesdaghinia

    2006-03-01

    Full Text Available Optimization of coagulation process  for efficient removal of Natural Organic Matters (NOM has gained a lot of focus over the last years to meet the requirements of enhanced coagulation. NOM comprises both particulate and soluble components which the latter usually comprises the main portion. Removal of soluble NOM from low turbidity waters by coagulation is not a successful process unless enough attention is paid to stages of formation and development of both micro and macro-flocs. This study, which presents experimental results from pilot scale research studies aimed at optimizing coagulation process applied to synthetic raw waters supplemented by adding commercial humic acid with low turbidity levels, explains how pH and turbidity can be controlled to maximize soluble NOM removal. The removal of NOM at various coagulant doses and coagulation pHs has been assessed through raw and treated (coagulated-settled water measurements of total organic carbon (TOC. For low turbidity waters, essential floc nucleation sites can be provided by creating synthetic turbidities, for example by adding clay. Adjusting the initial pH at 5.5 or adding clay before coagulant addition allows the formation of micro-flocs as well as formation of the insoluble flocs at low coagulant doses.

  8. Charging and coagulation of radioactive and nonradioactive particles in the atmosphere

    International Nuclear Information System (INIS)

    Kim, Yong-ha; Yiacoumi, Sotira

    2016-01-01

    Charging and coagulation influence one another and impact the particle charge and size distributions in the atmosphere. However, few investigations to date have focused on the coagulation kinetics of atmospheric particles accumulating charge. This study presents three approaches to include mutual effects of charging and coagulation on the microphysical evolution of atmospheric particles such as radioactive particles. The first approach employs ion balance, charge balance, and a bivariate population balance model (PBM) to comprehensively calculate both charge accumulation and coagulation rates of particles. The second approach involves a much simpler description of charging, and uses a monovariate PBM and subsequent effects of charge on particle coagulation. The third approach is further simplified assuming that particles instantaneously reach their steady-state charge distributions. It is found that compared to the other two approaches, the first approach can accurately predict time-dependent changes in the size and charge distributions of particles over a wide size range covering from the free molecule to continuum regimes. The other two approaches can reliably predict both charge accumulation and coagulation rates for particles larger than about 0.04 micrometers and atmospherically relevant conditions. These approaches are applied to investigate coagulation kinetics of particles accumulating charge in a radioactive neutralizer, the urban atmosphere, and an atmospheric system containing radioactive particles. Limitations of the approaches are discussed.

  9. Simultaneous lactic acidification and coagulation by using recombinant Lactococcus lactis strain.

    Science.gov (United States)

    Raftari, M; Ghafourian, S; Abu Bakar, F

    2017-04-01

    This study was an attempt to create a novel milk clotting procedure using a recombinant bacterium capable of milk coagulation. The Rhizomucor pusillus proteinase (RPP) gene was sub-cloned into a pALF expression vector. The recombinant pALF-RPP vector was then electro-transferred into Lactococcus lactis. Finally, the milk coagulation ability of recombinant L. lactis carrying a RPP gene was evaluated. Nucleotide sequencing of DNA insertion from the clone revealed that the RPP activity corresponded to an open reading frame consisting of 1218 bp coding for a 43·45 kDa RPP protein. The RPP protein assay results indicated that the highest RPP enzyme expression with 870 Soxhlet units (SU) per ml and 7914 SU/OD were obtained for cultures which were incubated at pH 5·5 and 30°C. Interestingly, milk coagulation was observed after 205 min of inoculating milk with recombinant L. lactis carrying the RPP gene. The recombinant L. lactis carrying RPP gene has the ability to function as a starter culture for acidifying and subsequently coagulating milk by producing RPP as a milk coagulant agent. Creating a recombinant starter culture bacterium that is able to coagulate milk. It is significant because the recombinant L. lactis has the ability to work as a starter culture and milk coagulation agent. © 2016 The Society for Applied Microbiology.

  10. Critical assessment of chitosan as coagulant to remove cyanobacteria

    NARCIS (Netherlands)

    Lürling, Miquel; Noyma, Natalia Pessoa; Magalhães, Leonardo de; Miranda, Marcela; Mucci, Maíra; Oosterhout, Frank van; Huszar, Vera L.M.; Marinho, Marcelo Manzi

    2017-01-01

    Removal of cyanobacteria from the water column using a coagulant and a ballast compound is a promising technique to mitigate nuisance. As coagulant the organic, biodegradable polymer chitosan has been promoted. Results in this study show that elevated pH, as may be common during cyanobacterial

  11. Critical assessment of chitosan as coagulant to remove cyanobacteria

    NARCIS (Netherlands)

    Lurling, Miguel; Noyma, Natalia Pessoa; Magalhães, de Leonardo; Miranda, Marcela; Mucci, Maíra; Oosterhout, van F.; Huszar, Vera L.M.; Marinho, Marcelo Manzi

    2017-01-01

    Removal of cyanobacteria from the water column using a coagulant and a ballast compound is a promising technique to mitigate nuisance. As coagulant the organic, biodegradable polymer chitosan has been promoted. Results in this study show that elevated pH, as may be common during cyanobacterial

  12. Coagulation mechanism of salt solution-extracted active component in Moringa oleifera seeds

    OpenAIRE

    Okuda, Tetsuji; Baes, Aloysius U.; Nishijima, Wataru; Okada, Mitsumasa

    2001-01-01

    This study focuses on the coagulation mechanism by the purified coagulant solution (MOC-SC-PC) with the coagulation active component extracted from M. oleifera seeds using salt solution. The addition of MOC-SC-PC into tap water formed insoluble matters. The formation was responsible for kaolin coagulation. On the other hand, insoluble matters were not formed when the MOC-SC-PC was added into distilled water. The formation was affected by Ca2+ or other bivalent cations which may connect each m...

  13. Improvement of extraction method of coagulation active components from Moringa oleifera seed

    OpenAIRE

    Okuda, Tetsuji; Baes, Aloysius U.; Nishijima, Wataru; Okada, Mitsumasa

    1999-01-01

    A new method for the extraction of the active coagulation component from Moringa oleifera seeds was developed and compared with the ordinary water extraction method (MOC–DW). In the new method, 1.0 mol l-1 solution of sodium chloride (MOC–SC) and other salts were used for extraction of the active coagulation component. Batch coagulation experiments were conducted using 500 ml of low turbid water (50 NTU). Coagulation efficiencies were evaluated based on the dosage required to remove kaolinite...

  14. OPTIMISATION OF HIBISCUS SABDARIFFA AS A NATURAL COAGULANT TO TREAT CONGO RED IN WASTEWATER

    Directory of Open Access Journals (Sweden)

    MUN Y. YONG

    2016-02-01

    Full Text Available The process of coagulation is commonly practiced in water and wastewater treatment to reduce level of dissolved chemical, turbidity and so on with the usage of coagulant. Aluminium sulphate (alum is the most commonly used coagulant, however, recent studies show that residual aluminium in drinking water and sludge may induce Alzheimer’s disease and environmental issues. Natural coagulant which is environmental friendly and non-toxic is developed as an alternative to overcome these issues. In this work, Hibiscus Sabdariffa was studied as natural coagulant to treat dye wastewater containing Congo red. The seeds were extracted with different solvent such as distilled water, 0.5 M NaCl and 0.05 M NaOH to extract the coagulation agent. The working parameters were optimised using Response Surface Methodology (RSM. 0.5 M NaCl was found to have highest colour removal of 95.1 % among the solvents. In addition, Hibiscus Sabdariffa seed was found to be an effective coagulant that has 91.2 % colour removal at the optimal working condition of pH 2, 190 mg/L coagulant dosage at 400 ppm of dye concentration. It was also been identified that the performance of natural coagulant is comparable with conventional coagulant, aluminium sulphate with colour removal of 91.2 % and 92.3 % respectively.

  15. Removal of Arsenic from Drinking Water by Adsorption and Coagulation

    Science.gov (United States)

    Zhang, M.; Sugita, H.; Hara, J.; Takahashi, S.

    2013-12-01

    Removal of arsenic from drinking water has been an important issue worldwide, which has attracted greater attentions in recent years especially for supplying safe drinking water in developing countries. Although many kinds of treatment approaches that are available or applicable both in principle and practice, such as adsorption, coagulation, membrane filtration, ion exchange, biological process, electrocoagulation and so on, the first 2 approaches (i.e., adsorption and coagulation) are most promising due to the low-cost, high-efficiency, simplicity of treating systems, and thus can be practically used in developing countries. In this study, a literature survey on water quality in Bangladesh was performed to understand the ranges of arsenic concentration and pH of groundwater in Bangladesh. A series of tests were then organized and performed to investigate the effects of arsenic concentration, arsenic forms, pH, chemical compositions of the materials used for adsorption and coagulation, particle size distribution and treatment time on quality of treated water. The experimental results obtained in the study illustrated that both adsorption and coagulation can be used to effectively reduce the concentrations of either arsenic (V) or arsenic (III) from the contaminated water. Coagulation of arsenic with a magnesium-based material developed in this study can be very effective to remove arsenic, especially arsenic (V), from contaminated water with a concentration of 10 ppm to an undetectable level of 0.002 ppm by ICP analyses. Compared to arsenic (III), arsenic (V) is easier to be removed. The materials used for adsorption and coagulation in this study can remove arsenic (V) up to 9 mg/g and 6 mg/g, and arsenic (III) up to 4 mg/g and 3 mg/g, respectively, depending on test conditions and compositions of the materials being used. The control of pH during treatment can be a challenging technical issue for developing both adsorbent and coagulant. Keywords: Water Treatment

  16. Bladder perforation owing to a unipolar coagulating device.

    Science.gov (United States)

    Pakter, J; Budnick, L D

    1981-09-15

    A report on a patient who sustained a burn and perforation of the urinary bladder from visible sparks emanating from a unipolar coagulating device during the couse of laparoscopic sterilization is presented. It is the first report of urinary bladder burns using a unipolar coagulating device. A 24-year-old woman, gravida 10, para 3, abortus 7, underwent a laparoscopic sterilization with a unipolar coagulating device. As the physician was finishing the coagulation, a spark from the device caused a 1-2 cm burn with a central area of perforation into the urinary bladder. Conservative treatment was recommended, and consisted of Foley catheterization and drainage for 5 days. Initial urine culture revealed Klebsiella species, and oral ampicillin was prescribed. Hematuria was noted throughout the patient's hospitalization, and blood clots were present in the urine on Day 2 postoperation. The patient had no abdominal or flank pain, was afebrile, and had a stable hemoglobin level during the hospital stay. Cystography was performed on Day 5 postoperatively and demonstrated no perforation. Foley catheter was removed. Patient was discharged 2 days later and remains in good health 3 months postoperatively.

  17. External quality assurance of fibrinogen assays using normal plasma: results of the 2008 College of American Pathologists proficiency testing program in coagulation.

    Science.gov (United States)

    Cunningham, Mark T; Olson, John D; Chandler, Wayne L; Van Cott, Elizabeth M; Eby, Charles S; Teruya, Jun; Hollensead, Sandra C; Adcock, Dorothy M; Allison, Paul M; Kottke-Marchant, Kandice K; Smith, Marc D

    2012-07-01

    Proper diagnosis and therapy of fibrinogen deficiency requires high-quality fibrinogen assays. To assess the interlaboratory bias, precision, and grading of fibrinogen assays used by laboratories participating in the United States College of American Pathologists proficiency testing program in coagulation. Two identical vials of normal plasma were sent to more than 3500 laboratories. Participants measured fibrinogen levels using local methods. Fifty different fibrinogen methods were evaluated. All-method bias was 8.3% (range of method-specific biases, 0.0%-27.0%) and all-method coefficient of variation was 7.7% (range of method-specific coefficients of variation, 0.7%-25.8%). After controlling for reagent/instrument type, mean fibrinogen levels were 11.6% higher for prothrombin time-based reagents compared to Clauss (P graded as pass or fail using a target range of ±20% from the method mean (total pass rate, 98.8%). Total fail rate was 3.0-fold lower for mechanical instruments compared to photo-optical (0.5% versus 1.5%, P  =  .001). Nonetheless many photo-optical methods had very high precision and very low fail rates. Fibrinogen assays showed highly variable methodology and performance characteristics. Bias, precision, and grading were affected by the type of reagent or instrument used.

  18. Profile of Cardiovascular Risk Factors in Patients with Coronary Heart Disease, Normal and Impaired Carbohydrate Metabolism

    Directory of Open Access Journals (Sweden)

    І.V. Cherniavska

    2015-11-01

    Full Text Available The aim of research was to conduct the comparative analysis of the profile of cardiovascular risk factors in patients with coronary heart disease (CHD and normal either impaired carbohydrate metabolism. Materials and methods. One hundred and forty two patients were observed. In order to estimate the rate of different forms of CHD depending on the state of carbohydrate metabolism such groups were formed: the first group consisted of 83 patients with type 2 diabetes mellitus (DM, the second group involved 34 patients with impaired glucose tolerance (IGT, the third group consisted of 25 patients with normal carbohydrate metabolism. The ischemic changes of myocardium were detected by ambulatory ECG monitoring with the obligatory achievement of submaximal heart rate during the research. Results. Silent myocardial ischemia was educed in 19 (22.9 % patients with type 2 DM, in 3 (8.8 % persons with IGT and in 2 (8.0 % patients with normal carbohydrate metabolism. Smoking, burdened heredity, violation in the haemostatic system more often occurred in the group of patients with type 2 DM and silent myocardial ischemia in comparison with the patients with type 2 DM without CHD. The profile of general population cardiovascular risk factors in patients with CHD and type 2 DM belongs to the most unfavorable. At the same time for patients with early violations of carbohydrate metabolism and normal carbohydrate metabolism such profile statistically does not differentiate meaningfully. Conclusions. Patients with type 2 DM and silent myocardial ischemia as compared to patients with type 2 DM without CHD have more expressed violations of indexes of general population cardiovascular risk factors for certain.

  19. Continuous 24-hour ocular dimensional profile recording in medically treated normal-tension glaucoma

    Directory of Open Access Journals (Sweden)

    Lee JWY

    2015-01-01

    Full Text Available Jacky WY Lee,1,2 Lin Fu,1 Jennifer WH Shum,1 Jonathan CH Chan,3 Jimmy SM Lai1 1Department of Ophthalmology, The University of Hong Kong, Hong Kong; 2Department of Ophthalmology, Caritas Medical Centre, Hong Kong; 3Department of Ophthalmology, Queen Mary Hospital, Hong Kong Purpose: To analyze the 24-hour ocular dimensional profile in normal-tension glaucoma (NTG patients on medical treatment.Methods: Consecutive, medically treated NTG subjects were recruited from a university eye center. Subjects were on a mean of 1.7±0.7 types of antiglaucoma medications and 56.6% were on a prostaglandin analog. A contact lens-based sensor device was worn in one eye of NTG patients to record the intraocular pressure (IOP-related profile for 24 hours, recording the following: variability from mean over 24 hours, nocturnally and diurnally, as well as the number of peaks and troughs diurnally and nocturnally.Results: In 18 NTG subjects, the nocturnal variability around the mean contact lens-based sensor device signal was 48.9% less than the diurnal variability around the mean. The number of peaks was 54.7% less during the nocturnal period than during the diurnal period. The rate of increase in the ocular dimensional profile when going to sleep was significantly greater than the rate of decrease upon waking (P<0.001.Conclusion: In medically treated NTG subjects, there was more variability in the IOP-related pattern during the daytime and there were fewer peaks during sleep. Keywords: intraocular pressure, 24-hour, normal tension glaucoma

  20. Ex Vivo Liver Experiment of Hydrochloric Acid-Infused and Saline-Infused Monopolar Radiofrequency Ablation: Better Outcomes in Temperature, Energy, and Coagulation

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Xiong-ying; Gu, Yang-kui; Huang, Jin-hua, E-mail: huangjh@sysucc.org.cn; Gao, Fei; Zou, Ru-hai; Zhang, Tian-qi [Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China (China)

    2016-04-15

    ObjectiveTo compare temperature, energy, and coagulation between hydrochloric acid-infused radiofrequency ablation (HAIRFA) and normal saline-infused radiofrequency ablation (NSIRFA) in ex vivo porcine liver model.Materials and Methods30 fresh porcine livers were excised in 60 lesions, 30 with HAIRFA and the other 30 with NSIRFA. Both modalities used monopolar perfusion electrode connected to a RF generator set at 103 °C and 30 W. In each group, ablation time was set at 10, 20, or 30 min (10 lesions from each group at each time). We compared tissue temperatures (at 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 cm away from the electrode tip), average power, deposited energy, deposited energy per coagulation volume (DEV), coagulation diameters, coagulative volume, and spherical ratio between the two groups.ResultsTemperature–time curves showed that HAIRFA provided progressively greater heating than that of NSIRFA. At 30 min, mean average power, deposited energy, coagulation volumes (113.67 vs. 12.28 cm{sup 3}) and diameters, and increasing in tissue temperature were much greater with HAIRFA (P < 0.001 for all), except DEV was lower (456 vs. 1396 J/cm{sup 3}, P < 0.001). The spherical ratio was closer to 1 with HAIRFA (1.23 vs. 1.46). Coagulation diameters, volume, and average power of HAIRFA increased significantly with longer ablation times. While with NSIRFA, these characteristics were stable till later 20 min, except the power decreased with longer ablation times.ConclusionsHAIRFA creates much larger and more spherical lesions by increasing overall energy deposition, modulating thermal conductivity, and transferring heat during ablation.

  1. Distribution functions and moments in the theory of coagulation

    International Nuclear Information System (INIS)

    Pich, J.

    1990-04-01

    Different distribution functions and their moments used in the Theory of coagulation are summarized and analysed. Relations between the moments of these distribution functions are derived and the physical meaning of individual moments is briefly discussed. The time evolution of the moment of order zero (total number concentration) during the coagulation process is analysed for the general kernel of the Smoluchowski equation. On this basis the time evolution of certain physically important quantities related to this moment such as mean particle size, surface and volume as well as surface concentration is described. Equations for the half time of coagulation for the general collision frequency factor are derived. (orig.) [de

  2. Coagulation parameters in copperhead compared to other Crotalinae envenomation: secondary analysis of the F(ab')2 versus Fab antivenom trial.

    Science.gov (United States)

    Gerardo, Charles J; Vissoci, Joao R Nickenig; Brown, Michael W J; Bush, Sean P

    2017-02-01

    Coagulation derangements in copperhead envenomation are considered less severe than other crotaline envenomations, resulting in recommendations to limit both coagulation testing and antivenom treatment. A prospective, blinded, multicenter, randomized clinical trial comparing the effectiveness of F(ab') 2 versus Fab antivenom in crotaline envenomation patients was completed in 2011. We determined the difference between coagulation parameters in copperhead compared to other crotaline envenomations. We performed a post hoc analysis comparing the coagulation parameters (platelets and fibrinogen) prospectively obtained in the aforementioned trial. All the patients received antivenom in one of three treatment arms [F(ab') 2 with maintenance, F(ab') 2 with placebo maintenance, or Fab with maintenance]. Coagulation parameters were measured at pretreatment baseline, during acute hospitalization, day 5, day 8, and day 15 post-envenomation. Mean platelet count and fibrinogen levels for the copperhead and other crotaline groups were compared. The platelet and fibrinogen point estimates with distribution are presented graphically over time. 122 patients were enrolled in the study. There were 22 patients with copperhead envenomation, 93 with other crotaline envenomations, and 7 that could not be definitively determined. The mean age was 42 (SD 20) years. There was a minor pretreatment difference in mean baseline platelet count between the copperhead group (246 × 109/L 95% CI 215, 277) compared to other crotaline envenomation patients (184 × 109/L 95% CI 167, 202). There was a modest pretreatment difference in mean fibrinogen level between copperhead patients (345 mg/dL 95% CI 277, 415) and other crotaline patients (261mg/dL 95% CI 241, 281). Pretreatment coagulation parameter means were normal and converged post treatment. On average, copperhead envenomations have less severe initial coagulation derangements. However, in mild envenomations, differences in laboratory

  3. A quantitative comparison between electrocoagulation and chemical coagulation for boron removal from boron-containing solution

    International Nuclear Information System (INIS)

    Yilmaz, A. Erdem; Boncukcuoglu, Recep; Kocakerim, M. Muhtar

    2007-01-01

    This paper provides a quantitative comparison of electrocoagulation and chemical coagulation approaches based on boron removal. Electrocoagulation process delivers the coagulant in situ as the sacrificial anode corrodes, due to a fixed current density, while the simultaneous evolution of hydrogen at the cathode allows for pollutant removal by flotation. By comparison, conventional chemical coagulation typically adds a salt of the coagulant, with settling providing the primary pollutant removal path. Chemical coagulation was carried out via jar tests using aluminum chloride. Comparison was done with the same amount of coagulant between electrocoagulation and chemical coagulation processes. Boron removal obtained was higher with electrocoagulation process. In addition, it was seen that chemical coagulation has any effect for boron removal from boron-containing solution. At optimum conditions (e.g. pH 8.0 and aluminum dose of 7.45 g/L), boron removal efficiencies for electrocoagulation and chemical coagulation were 94.0% and 24.0%, respectively

  4. A quantitative comparison between electrocoagulation and chemical coagulation for boron removal from boron-containing solution

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, A. Erdem [Atatuerk University, Faculty of Engineering, Department of Environmental Engineering, 25240 Erzurum (Turkey)], E-mail: aerdemy@atauni.edu.tr; Boncukcuoglu, Recep [Atatuerk University, Faculty of Engineering, Department of Environmental Engineering, 25240 Erzurum (Turkey); Kocakerim, M. Muhtar [Atatuerk University, Faculty of Engineering, Department of Chemical Engineering, 25240 Erzurum (Turkey)

    2007-10-22

    This paper provides a quantitative comparison of electrocoagulation and chemical coagulation approaches based on boron removal. Electrocoagulation process delivers the coagulant in situ as the sacrificial anode corrodes, due to a fixed current density, while the simultaneous evolution of hydrogen at the cathode allows for pollutant removal by flotation. By comparison, conventional chemical coagulation typically adds a salt of the coagulant, with settling providing the primary pollutant removal path. Chemical coagulation was carried out via jar tests using aluminum chloride. Comparison was done with the same amount of coagulant between electrocoagulation and chemical coagulation processes. Boron removal obtained was higher with electrocoagulation process. In addition, it was seen that chemical coagulation has any effect for boron removal from boron-containing solution. At optimum conditions (e.g. pH 8.0 and aluminum dose of 7.45 g/L), boron removal efficiencies for electrocoagulation and chemical coagulation were 94.0% and 24.0%, respectively.

  5. Effect of starters and ripening time on the physicochemical, nitrogen fraction and texture profile of goat's cheese coagulated with a vegetable coagulant (Cynara cardunculus).

    Science.gov (United States)

    García, Víctor; Rovira, Silvia; Boutoial, Khalid; Ferrandini, Eduardo; López Morales, María B

    2014-02-01

    The increase in the demand for goat's cheese throughout the world has encouraged research into the development of new related products with different textural characteristics. The aim of this work was to study the effect of three commercial starter cultures through the assessment of physicochemical and textural characteristics of goat's milk cheeses made with vegetable coagulant (Cynara cardunculus) during ripening. Use of the different starter cultures produced a significant effect (P starters ensures the correct acidification rate and produced cheeses with lower pH values and greater hardness. Use of thermophilic starter cultures produces cheeses with less instrumental hardness and the use of mixed cultures produced less proteolysis. These results are found useful for selecting the most suitable starter for the development of new goat's cheeses. © 2013 Society of Chemical Industry.

  6. Arsenic removal in water by means of coagulation-flocculation processes

    International Nuclear Information System (INIS)

    Franco, M. F.; Carro P, M. E.

    2014-01-01

    Arsenic and arsenical compounds are considered as carcinogenic and risky for humans according to epidemiological evidence related with the ingestion of arsenical water during a long period. In many places the only source of drinking water contains arsenic and, therefore, removal strategies have to be investigated. This work shows experimental results of coagulation-flocculation processes implemented to evaluate the efficiency in the removal of arsenic from drinking water. The main objectives include the evaluation of the relevant aspect that controls the removal efficiency. Experimental tests were performed with coagulant concentrations from 5 to 500 mg/L, solid particle concentrations from 0 to 6000 mg/L, and initial arsenic concentrations from 0.5 to 5 mg/L. These variables were simultaneously varied in more than 100 experiments. The efficiency in remediation ranged from 0% to 95%. Removal efficiency near 95% was obtained when using ferric chloride as coagulant, and was close to 80% when using aluminium sulfate as coagulant in arsenate solutions. The remediation efficiency decreased significantly when the ferric chloride concentration was higher than 50 mg/L in relation to the obtained results for aluminum sulfate for different type and concentration of soil particles. The highest removal efficiency were obtained at ph between 3 and 5 in oxidized solutions. Obtained results simulated by means of multiple linear regression analysis (R>0.90) allow determining that the main parameters that control the removal of arsenic from drinking water are coagulant concentration, ph, and solid particles concentration. Conversely, particle mineralogy and coagulant type have less significant effect on the removal by means of coagulation-flocculation mechanisms. Obtained results are relevant for the removal of As in water treatment plants as well as for the development of small scale filters. The samples were studied by scanning electron microscopy and energy dispersive X

  7. Effect of chitosan and coagulation factors on the wound repair phenotype of bioengineered blood clots.

    Science.gov (United States)

    Hoemann, Caroline D; Marchand, Catherine; Rivard, Georges-Etienne; El-Gabalawy, Hani; Poubelle, Patrice E

    2017-11-01

    Controlling the blood clot phenotype in a surgically prepared wound is an evolving concept in scaffold-guided tissue engineering. Here, we investigated the effect of added chitosan (80% or 95% Degree of Deacetylation, DDA) or coagulation factors (recombinant human Factor VIIa, Tissue Factor, thrombin) on inflammatory factors released by blood clots. We tested the hypothesis that 80% DDA chitosan specifically enhances leukotriene B 4 (LTB 4 ) production. Human or rabbit whole blood was combined with isotonic chitosan solutions, coagulation factors, or lipopolysaccharide, cultured in vitro at 37°C, and after 4hours the serum was assayed for LTB 4 or inflammatory factors. Only 80% DDA chitosan clots produced around 15-fold more LTB 4 over other clots including 95% DDA chitosan clots. All serum contained high levels of PDGF-BB and CXCL8. Normal clots produced very low type I cytokines compared to lipopolysaccharide clots, with even lower IL-6 and IL-12 and more CCL3/CCL4 produced by chitosan clots. Coagulation factors had no detectable effect on clot phenotype. Conclusion In blood clots from healthy individuals, 80% DDA chitosan has a unique influence of inducing more LTB 4 , a potent neutrophil chemoattractant, with similar production of PDGF-BB and CXCL8, and lower type I cytokines, compared to whole blood clots. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Effect of THI on milk coagulation properties of Holstein-Friesian dairy cattle

    Directory of Open Access Journals (Sweden)

    Simone Beux

    Full Text Available ABSTRACT The objective of this study was to evaluate the effect of temperature-humidity index (THI on the milk coagulation properties of Holstein-Friesian dairy cattle from northeast part of Italy. A total of 592 individual milk samples from six dairy herds were evaluated. The milk coagulation properties traits analysed were milk rennet coagulation time and curd firmness, as well as the fat, protein, and casein contents, pH, milk aptitude to coagulate (IAC, and the somatic cell count. The THI was determined during the periods of sample collection. The THI results showed that values of up to 75 did not significantly change the IAC values; however, when the THI values were above 75, the IAC decreased significantly. The control of THI can be used to guarantee appropriate milk coagulation properties.

  9. Application of Moringa Oleifera Seed Powder For Iron (III Coagulation on Local Water Resources

    Directory of Open Access Journals (Sweden)

    Fadillah Utami Prasetyaningtyas

    2013-07-01

    Full Text Available This research aims to know the effect of the use of powder moringa seed to coagulant mass and coagulation process, and its effectiveness to increase the quality of pure water. This research uses factorial research design and statistic test MANOVA. To analyse water quality, the researcher uses Fe parameter.  A graphic of coagulant mass and time for each parameter is used to analyse the data. Based on the research result, the uses of moringa seed as coagulant in each 300 mL mineral water gives a possitives result to the river water sample using 100 mg coagulant mass and sedimentations time for 60 minutes, well water sample using 500 mg coagulant mass and sedimentations time for 60 minutes, tap water sample using 300 mg  coagulant mass and sedimentations time for 90 minutes. The effective coagulant that increase the water quality on well water is 98,32% of moringa seed powder, on river water is 96,64%  and for tap water is 25,62%.

  10. Influential factors of formation kinetics of flocs produced by water treatment coagulants.

    Science.gov (United States)

    Wu, Chunde; Wang, Lin; Hu, Bing; Ye, Jian

    2013-05-01

    The growth rate and size of floc formation is of great importance in water treatment especially in coagulation process. The floc formation kinetics and the coagulation efficiency of synthetic water were investigated by using an on-line continuous optical photometric dispersion analyze and the analysis of water quality. Experimental conditions such as alum dosage, pH value for coagulation, stirring intensity and initial turbidity were extensively examined. The photometric dispersion analyze results showed that coagulation of kaolin suspensions with two coagulants (alum and polyaluminium chloride) could be taken as a two-phase process: slow and rapid growth periods. Operating conditions with higher coagulant doses, appropriate pH and average shear rate might be particularly advantageous. The rate of overall floc growth was mainly determined by a combination of hydraulic and water quality conditions such as pH and turbidity. The measurement of zeta potential indicates that polyaluminium chloride exhibited higher charge-neutralizing ability than alum and achieved lower turbidities than alum for equivalent Al dosages. Under the same operating conditions, the alum showed a higher grow rate, but with smaller floc size.

  11. Alanine aminotransferase is associated with an adverse nocturnal blood glucose profile in individuals with normal glucose regulation.

    Directory of Open Access Journals (Sweden)

    Jian Zhou

    Full Text Available OBJECTIVE: Although the association between alanine aminotransferase (ALT levels and risk of type 2 diabetes is well-studied, the effects of slightly increased ALT levels within the normal range on the temporal normal glucose profile remains poorly understood. METHODS: A total of 322 Chinese subjects without impaired glucose tolerance or previous diagnoses of diabetes were recruited for study from 10 hospitals in urban areas across China. All subjects wore a continuous glucose monitoring (CGM system for three consecutive days. The diurnal (06∶00-20∶00 and nocturnal (20∶00-06∶00 mean blood glucose (MBG levels were calculated. Subjects were stratified by ALT quartile level and correlation analyses were performed. RESULTS: The median ALT level was 17 IU/L, and subjects with ALT ≥17 IU/L had higher nocturnal MBG level than those with ALT 0.05. Multivariate stepwise regression analysis of elevated nocturnal MBG identified increased HOMA-IR, elevated ALT levels, and decreased homeostatic model assessment of ß-cell function as independent factors (all, P<0.05. CONCLUSIONS: Mildly elevated ALT levels, within the normal range, are associated with unfavorable nocturnal glucose profiles in Chinese subjects with normal glucose regulation.

  12. Coagulation-flocculation studies of laboratory wastewater using different combinations

    International Nuclear Information System (INIS)

    Butt, M. T.; Khan, R. A.; Khokar, A.; Iqbal, K.

    2013-01-01

    This study was conducted on the wastewater of PCSIR Laboratories complex Lahore. Both single as well as blended form was used in order to achieve maximum results and to reduce the cost. These experiments were conducted in Hudson Jars of one liter capacity using the coagulation technique for the removal of total suspended solids (TSS) and turbidity. The pH range was 6-8 and 4-10 for treatment. Four coagulants were used such as FeCl 3 , AlCl 3 . Alum and FeSO 4 , to remove the turbidity in single and blended form. Results of single coagulant are FeCl 3 from 39.7 to 11.51 NTU; AlCl 3 from 47.48 to 11.8 NTU. Alum 43 to 25.3NTU.FeSO 4 showed increasing trend in turbidity 53 to 120 NTU. The blended set of coagulants AlCl 3 +Alum turbidity from 45 to 18.55 NTU. The AlCl 3 and FeCl 3 showed almost similar results but after overnight settling results were excellent and alum showed also good results. The turbidity was removed from 54 to 27 NTU, 48 to 22 NTU, 44 to 17 NTU, and after overnight settling 33 to 4 NTU. The results of blended coagulants FeCl 3 +AlCl 3 after one, two and three hours settling were also studied and found best and blend AlCl3+Alum showed also similar trend and the blend of Alum+FeCl 3 after overnight settling was excellent. The same coagulants and its blended form were used for TSS removal and results are 278 to 7 mg/L, in blended form AlCl 3 +Alum show similar results but Alum + FeCl 3 showed excellent results. The TSS and turbidity removal was 87%, 97.5%. (author)

  13. Evaluation of Chitin as Natural Coagulant in Water Treatment

    Directory of Open Access Journals (Sweden)

    V. Saritha

    2012-04-01

    Full Text Available The use of synthetic coagulants is not regarded as suitable due to health and economic considerations. The present study was aimed to investigate the effects of alum as coagulant in conjunction with chitin as coagulant aid on the removal of turbidity, hardness and Escherichia coli from water. A conventional jar test apparatus was employed for the tests. The experiment was conducted at three different pH conditions of 6, 7 and 8. The dosages chosen were 0.5, 1, 1.5 and 2mg/l. The results showed that turbidity decrease provided also a primary Escherichia coli reduction. Hardness removal efficiency was observed to be 93% at pH 7 with 1mg/l concentration by alum whereas chitin was stable at all the pH ranges showing highest removal at 1 and 1.5mg/l with pH 7. At low concentration chitin showed marginally better performance on hardness. In conclusion, using natural coagulants results in considerable savings in chemicals and sludge handling cost may be achieved.

  14. Use of non-Conventional Material to Remove Cu+2 ions from Aqueous Solutions using Chemical Coagulation

    Directory of Open Access Journals (Sweden)

    Muna Yousif Abdul. Ahad

    2015-05-01

    Full Text Available Coagulation - flocculation are basic chemical engineering method in the treatment of metal-bearing industrial wastewater because it removes colloidal particles, some soluble compounds and very fine solid suspensions initially present in the wastewater by destabilization and formation of flocs. This research was conducted to study the feasibility of using natural coagulant such as okra and mallow and chemical coagulant such as alum for removing Cu and increase the removal efficiency and reduce the turbidity of treated water. Fourier transform Infrared (FTIR was carried out for okra and mallow before and after coagulant to determine their type of functional groups. Carbonyl and hydroxyl functional groups on the surface of okra and mallow were the major groups responsible for coagulation process. By using alum (conventional coagulants, okra and mallow (as a primary coagulant or in combination with the other two primary coagulants and by the jar testing, the optimum pH-value and dose of the coagulants were determined. The results indicated that the optimal pH values were 6.7, 8 and 6 for alum, okra and mallow, respectively. Mathematical modeling show significant results (sig.<0.05 for the % Cu removal (dependent variable with respect to coagulant dose (independent variable for the okra as a primary coagulant, alum with okra and alum with mallow as binary coagulants and alum, okra and mallow as ternary coagulants .

  15. Normal Weight but Low Muscle Mass and Abdominally Obese: Implications for the Cardiometabolic Risk Profile in Chronic Obstructive Pulmonary Disease.

    Science.gov (United States)

    Beijers, Rosanne J H C G; van de Bool, Coby; van den Borst, Bram; Franssen, Frits M E; Wouters, Emiel F M; Schols, Annemie M W J

    2017-06-01

    It is well established that low muscle mass affects physical performance in chronic obstructive pulmonary disease (COPD). We hypothesize that combined low muscle mass and abdominal obesity may also adversely influence the cardiometabolic risk profile in COPD, even in those with normal weight. The cardiometabolic risk profile and the responsiveness to 4 months high-intensity exercise training was assessed in normal-weight patients with COPD with low muscle mass stratified by abdominal obesity. This is a cross-sectional study including 81 clinically stable patients with COPD (age 62.5 ± 8.2 years; 50.6% males; forced expiratory volume in 1 second 55.1 ± 19.5 percentage predicted) with fat-free mass index risk profile. Triglycerides showed a significant decrease, while the HOMA-IR increased. Abdominal obesity is highly prevalent in normal-weight patients with COPD with low muscle mass who showed an increased cardiometabolic risk compared with patients without abdominal obesity. This cardiometabolic risk profile was not altered after 4 months of exercise training. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  16. Blood coagulation factor VIII

    Indian Academy of Sciences (India)

    Factor VIII (FVIII) functions as a co-factor in the blood coagulation cascade for the proteolytic activation of factor X by factor IXa. Deficiency of FVIII causes hemophilia A, the most commonly inherited bleeding disorder. This review highlights current knowledge on selected aspects of FVIII in which both the scientist and the ...

  17. Removal of algal blooms from freshwater by the coagulation-magnetic separation method.

    Science.gov (United States)

    Liu, Dan; Wang, Peng; Wei, Guanran; Dong, Wenbo; Hui, Franck

    2013-01-01

    This research investigated the feasibility of changing waste into useful materials for water treatment and proposed a coagulation-magnetic separation technique. This technique was rapid and highly effective for clearing up harmful algal blooms in freshwater and mitigating lake eutrophication. A magnetic coagulant was synthesized by compounding acid-modified fly ash with magnetite (Fe(3)O(4)). Its removal effects on algal cells and dissolved organics in water were studied. After mixing, coagulation, and magnetic separation, the flocs obtained from the magnet surface were examined by SEM. Treated samples were withdrawn for the content determination of chlorophyll-a, turbidity, chemical oxygen demand (COD), total nitrogen, and total phosphorus. More than 99 % of algal cells were removed within 5 min after the addition of magnetic coagulant at optimal loadings (200 mg L(-1)). The removal efficiencies of COD, total nitrogen, and phosphorus were 93, 91, and 94 %, respectively. The mechanism of algal removal explored preliminarily showed that the magnetic coagulant played multiple roles in mesoporous adsorption, netting and bridging, as well as high magnetic responsiveness to a magnetic field. The magnetic-coagulation separation method can rapidly and effectively remove algae from water bodies and greatly mitigate eutrophication of freshwater using a new magnetic coagulant. The method has good performance, is low cost, can turn waste into something valuable, and provides reference and directions for future pilot and production scale-ups.

  18. PILOT PLANT STUDY ON NATURAL WATER COAGULANTS AS COAGULAN AIDS FOR WATER SUPPLY

    Directory of Open Access Journals (Sweden)

    B BINA

    2001-06-01

    Full Text Available Introduction: Natural plant coagulants have an important role to play in provision of portable water to rural communities in the developing world. The plant material that their coagulation properties have been confirmed in previous lab scale studies and can be found widely in Iran was selected as coagulant aids. Pilot plant study was done to evaluate the efficiency of natural material such as Starch/Gum Tragacanth, Fenugreek and Yeast as coagulant aids in conjunction with comercial alum. Methods: The pilot was placed in Isfahan Water Treatment Plant (IWTP and efficiency of these materials in removal of turbidity from raw water enters the IWTP was evaluated. The results indicated while these materials were used as coagulant aids in concentration of 1-5 mg/l conjunction with alum are able to reduced the turbidity and final residuals turbidity meets the standards limits. Results: The coagulation efficiency of these material were found to be effected by certain physico-chemical factors, namely, concentration of suspended solids, divalent cation metal and time of agitation. The relative importance of these variable was evaluated. The results of COD test proved that the natural coagulant aids in the optimum doses produce no any significant organic residual. Discussion: Economical considerations showed that using of these material as coagulant aids can cause reduction in alum consumption and in some cases are more econmical than synthetic polyelectrolyte.

  19. A new inorganic-organic composite coagulant, consisting of polyferric sulphate (PFS) and polyacrylamide (PAA).

    Science.gov (United States)

    Moussas, P A; Zouboulis, A I

    2009-08-01

    Currently, research is focused on the synthesis of new composite coagulants, which are constituted of both inorganic and organic materials. In this paper, the development of relevant reagents was investigated, by combining the inorganic pre-polymerised iron-based coagulant Polyferric Sulphate (PFS) with an organic, non-ionic polymer (Polyacrylamide, PAA) under different PAA/Fe (mg/l) and OH/Fe molar ratios. Moreover, the new reagents were characterised in terms of typical properties, stability and morphological analysis (XRD, FTIR, SEM). Their coagulation performance, when treating low or high turbid kaolin-humic acid suspensions, was also investigated, whereas the applied coagulation mechanisms were discussed by using the Photometric Dispersion Analysis (PDA) analysis. The results show that the new coagulation reagents present improved properties, including increased effective polymer species concentration, and they exhibit very good stability. The respective tests using PDA confirmed that the predominant coagulation mechanism of PFS-PAA is the bridge formation mechanism. Coagulation experiments in low or high turbid kaolin-humic acid suspensions reveal that the novel composite reagent PFS-PAA exhibits better coagulation performance, when compared with simple PFS, in terms of zeta-potential reduction, turbidity and organic matter removal and residual iron concentration.

  20. Exact combinatorial approach to finite coagulating systems

    Science.gov (United States)

    Fronczak, Agata; Chmiel, Anna; Fronczak, Piotr

    2018-02-01

    This paper outlines an exact combinatorial approach to finite coagulating systems. In this approach, cluster sizes and time are discrete and the binary aggregation alone governs the time evolution of the systems. By considering the growth histories of all possible clusters, an exact expression is derived for the probability of a coagulating system with an arbitrary kernel being found in a given cluster configuration when monodisperse initial conditions are applied. Then this probability is used to calculate the time-dependent distribution for the number of clusters of a given size, the average number of such clusters, and that average's standard deviation. The correctness of our general expressions is proved based on the (analytical and numerical) results obtained for systems with the constant kernel. In addition, the results obtained are compared with the results arising from the solutions to the mean-field Smoluchowski coagulation equation, indicating its weak points. The paper closes with a brief discussion on the extensibility to other systems of the approach presented herein, emphasizing the issue of arbitrary initial conditions.

  1. Vegetable coagulants as alternative for treatment of wastewater in Mexico

    Directory of Open Access Journals (Sweden)

    Servando López-León

    2017-11-01

    Full Text Available This review addresses the various properties of natural coagulants, water, the chemical substance essential for life and the ideal solvent for a large number of compounds, it is commonly used with domestic, commercial and industrial purposes. After its use, it presents sewage to be retired before use it once again. To remove pollutant, water is subject to different physical, chemical and biological processes. Here, the clarification process uses aluminum and iron materials to remove the solids present; these materials are reported as health hazardous and toxic. In Mexico, regulatory frame work stablish that treated wastewater should do not exceed 0.2 mg/L of aluminum even though has been reported an increased risk of Alzheimer's in populations when water exceeds 0.1 mg/L. Natural coagulants have showed coagulation properties when are used in the clarification process, proven its advantages over traditional ones; such as low cost, good coagulant properties and safe health and non-toxic properties. Here, we enlist some vegetable species as alternatives to the traditional based on aluminum and iron. Additionally, these species are known to have origins on Mexico or being present extensively in the territory, making possible to think about them as alternative coagulants in the clarification process of the wastewater treatment process.

  2. Reduction of Turbidity of Water Using Locally Available Natural Coagulants

    Science.gov (United States)

    Asrafuzzaman, Md.; Fakhruddin, A. N. M.; Hossain, Md. Alamgir

    2011-01-01

    Turbidity imparts a great problem in water treatment. Moringa oleifera, Cicer arietinum, and Dolichos lablab were used as locally available natural coagulants in this study to reduce turbidity of synthetic water. The tests were carried out, using artificial turbid water with conventional jar test apparatus. Optimum mixing intensity and duration were determined. After dosing water-soluble extracts of Moringa oleifera, Cicer arietinum, and Dolichos lablab reduced turbidity to 5.9, 3.9, and 11.1 nephelometric turbidity unit (NTU), respectively, from 100 NTU and 5, 3.3, and 9.5, NTU, respectively, after dosing and filtration. Natural coagulants worked better with high, turbid, water compare to medium, or low, turbid, water. Highest turbidity reduction efficiency (95.89%) was found with Cicer arietinum. About 89 to 96% total coliform reduction were also found with natural coagulant treatment of turbid water. Using locally available natural coagulants, suitable, easier, and environment friendly options for water treatment were observed. PMID:23724307

  3. Multiple roles of the coagulation protease cascade during virus infection.

    Science.gov (United States)

    Antoniak, Silvio; Mackman, Nigel

    2014-04-24

    The coagulation cascade is activated during viral infections. This response may be part of the host defense system to limit spread of the pathogen. However, excessive activation of the coagulation cascade can be deleterious. In fact, inhibition of the tissue factor/factor VIIa complex reduced mortality in a monkey model of Ebola hemorrhagic fever. Other studies showed that incorporation of tissue factor into the envelope of herpes simplex virus increases infection of endothelial cells and mice. Furthermore, binding of factor X to adenovirus serotype 5 enhances infection of hepatocytes but also increases the activation of the innate immune response to the virus. Coagulation proteases activate protease-activated receptors (PARs). Interestingly, we and others found that PAR1 and PAR2 modulate the immune response to viral infection. For instance, PAR1 positively regulates TLR3-dependent expression of the antiviral protein interferon β, whereas PAR2 negatively regulates expression during coxsackievirus group B infection. These studies indicate that the coagulation cascade plays multiple roles during viral infections.

  4. Coagulation-flocculation studies of wastewaters

    NARCIS (Netherlands)

    Leentvaar, J.

    1982-01-01

    Although coagulation-flocculation processes have been practiced world-wide for almost a century in water treatment, several problems both in the theoretical and in the applied field have not been resolved yet. Especially interpretation of practical results with respect to governing

  5. Cosmetic wastewater treatment by coagulation and advanced oxidation processes.

    Science.gov (United States)

    Naumczyk, Jeremi; Bogacki, Jan; Marcinowski, Piotr; Kowalik, Paweł

    2014-01-01

    In this study, the treatment process of three cosmetic wastewater types has been investigated. Coagulation allowed to achieve chemical oxygen demand (COD) removal of 74.6%, 37.7% and 74.0% for samples A (Al2(SO4)3), B (Brentafloc F3) and C (PAX 16), respectively. The Fenton process proved to be effective as well - COD removal was equal to 75.1%, 44.7% and 68.1%, respectively. Coagulation with FeCl3 and the subsequent photo-Fenton process resulted in the best values of final COD removal equal to 92.4%, 62.8% and 90.2%. In case of the Fenton process, after coagulation these values were equal to 74.9%, 50.1% and 84.8%, while in case of the H2O2/UV process, the obtained COD removal was 83.8%, 36.2% and 80.9%. High value of COD removal in the Fenton process carried out for A and C wastewater samples was caused by a significant contribution of the final neutralization/coagulation. Very small effect of the oxidation reaction in the Fenton process in case of sample A resulting from the presence of antioxidants, 'OH radical scavengers' in the wastewater.

  6. Treatment of melanoidin wastewater by anaerobic digestion and coagulation.

    Science.gov (United States)

    Arimi, Milton M; Zhang, Yongjun; Götz, Gesine; Geißen, Sven-Uwe

    2015-01-01

    Melanoidins are dark-coloured recalcitrant pollutants found in many industrial wastewaters including coffee-manufacturing effluent, molasses distillery wastewater (MDWW) and other wastewater with molasses as the raw material. The wastewaters are mostly treated with anaerobic digestion after some dilution to minimize the inhibition effect. However, the dark colour and recalcitrant dissolved organic carbon (DOC) mainly caused by melanoidin are not effectively removed. The aim of this study was to investigate the removal of colour and remnant DOC by different coagulants from anaerobically digested MDWW. From the six coagulants tested, ferric chloride had the highest melanoidin (48%), colour (92.7%) and DOC (63.3%) removal at pH 5 and a dosage of 1.6 g/l. Both polymer and inorganic salt coagulants tested had optimal colour, melanoidin and DOC removal at acidic pH. The molecular size distribution of synthetic melanoidins by liquid chromatography-organic carbon detection indicated a preferential removal of high-molecular-weight melanoidins over low weight melanoidins by the coagulation. Further studies should focus on how to improve biodegradability of the treated effluent for it to be reused as dilution water for anaerobic digestion.

  7. Removal of natural organic matter in drinking water treatment by coagulation: A comprehensive review.

    Science.gov (United States)

    Sillanpää, Mika; Ncibi, Mohamed Chaker; Matilainen, Anu; Vepsäläinen, Mikko

    2018-01-01

    Natural organic matter (NOM) is a complex matrix of organic substances produced in (or channeled to) aquatic ecosystems via various biological, geological and hydrological cycles. Such variability is posing a serious challenge to most water treatment technologies, especially the ones designed to treat drinking water supplies. Lately, in addition to the fluctuating composition of NOM, a substantial increase of its concentration in fresh waters, and also municipal wastewater effluents, has been reported worldwide, which justifies the urgent need to develop highly efficient and versatile water treatment processes. Coagulation is among the most applied processes for water and wastewater treatment. The application of coagulation to remove NOM from drinking water supplies has received a great deal of attention from researchers around the world because it was efficient and helped avoiding the formation of disinfection by products (DBPs). Nonetheless, with the increased fluctuation of NOM in water (concentration and composition), the efficiency of conventional coagulation was substantially reduced, hence the need to develop enhanced coagulation processes by optimizing the operating conditions (mainly the amount coagulants and pH), developing more efficient inorganic or organic coagulants, as well as coupling coagulation with other water treatment technologies. In the present review, recent research studies dealing with the application of coagulation for NOM removal from drinking water supplies are presented and compared. In addition, integration schemes combining coagulation and other water treatment processes are presented, including membrane filtration, oxidation, adsorption and others processes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Review of Coagulation Technology for Removal of Arsenic: Case of Chile

    OpenAIRE

    Sancha, Ana María

    2006-01-01

    Coagulation technology has been used since 1970 in northern Chile for removing arsenic from drinking-water. This experience suggests that coagulation is an effective technology for the removal of arsenic. It is currently possible to reduce arsenic from 400 μg/L to 10 μg/L at a rate of 500 L/sec, assuming pH, oxidizing and coagulation agents are strictly controlled. The Chilean experience with the removal of arsenic demonstrates that the water matrix dictates the selection of the arsenic-remov...

  9. Coagulation-Adsorption Hybrid Process for the Treatment of Dyes and Pigments Wastewater

    Directory of Open Access Journals (Sweden)

    Abdul Karim Shah

    2013-10-01

    Full Text Available The study aimed to improve the effectiveness of dyes and pigments wastewater treatment. Hybrid system of adsorption and coagulation was applied for the reduction of COD, color, turbidity and TSS. Activated carbon adsorbent was prepared from a waste of sugar industry boiler. It was processed through physicochemical treatment with sulfuric acid following grinding, sieving, washing and drying unit operations. Combined wastewater of dyes and pigments manufacturing plant was treated with a hybrid process of coagulation and adsorption. FeCl 3, FeSO 4and Alum coagulants were tested individually and found them less effective. It was revealed that FeCl 3 coagulation, adsorption and hybrid process reduced COD (41, 51 and 54%, Color (67, 70 and 89%, turbidity (69, 71 and 90% and TSS (82, 93 and 97% respectively. Combination of FeCl3 -SBFA (Sugarcane Bagasse Fly Ash proved 90% efficient in removal than coagulation as an individual process. 4g adsorbent dose was optimized for this hybrid process

  10. Modelling of the Blood Coagulation Cascade in an In Vitro Flow System

    DEFF Research Database (Denmark)

    Andersen, Nina Marianne; Sørensen, Mads Peter; Efendiev, Messoud A.

    2010-01-01

    We derive a mathematical model of a part of the blood coagulation cascade set up in a perfusion experiment. Our purpose is to simulate the influence of blood flow and diffusion on the blood coagulation pathway. The resulting model consists of a system of partial differential equations taking...... and flow equations, which guarantee non negative concentrations at all times. The criteria is applied to the model of the blood coagulation cascade....

  11. REMOVAL OF ORGANIC MATTER FROM SURFACE WATER USING COAGULANTS WITH VARIOUS BASICITY

    Directory of Open Access Journals (Sweden)

    Lidia Dąbrowska

    2016-07-01

    Full Text Available Humic substances are a natural admixture of surface water and determine the level of organic pollution of water and colour intensity. Application of coagulation process in surface water treatment allows for decrease turbidity and colour of water, as well as organic matter content. In Poland most drinking water treatment plants use aluminium sulphate as a coagulant. Research works on pre-hydrolysed coagulants, e.g. polyaluminium chlorides (general formula Aln(OHmCl3n-m are also carried out. The aim of this study was to evaluate the effectiveness of the coagulation process using polyaluminium chlorides with different basicity, in reducing the level of pollution of surface water with organic substances. Apart from the typical indicators used to evaluate the content of organic compounds, the potential for trihalomethanes formation THM-FP was also determined. The influence of the type of coagulant (low, medium, highly alkaline on the efficiency of organic compound removal, determined as total organic carbon TOC, oxidisability OXI, absorbance UV254, was stated. Under the conditions of the coagulation (pH 7.2-7.4, temperature of 19-21°C, the best results were obtained using highly alkaline polyaluminium chlorides PAX-XL19F, PAX-XL1905 and PAX-XL1910S, decrease in TOC and OXI by 43-46%, slightly worse - 40-41% using low alkaline PAX18. Using the medium alkaline coagulants PAX-XL61 and PAXX-XL69, 30-35% removal of organic matter was obtained. Despite various effects of dissolved organic carbon removal, depending on the used coagulant, THM-FP in purified water did not differ significantly and ranged from 10.0 to 10.9 mgCHCl3 m-3. It was by 37-42% lower than in surface water.

  12. New treatment strategies for disseminated intravascular coagulation based on current understanding of the pathophysiology

    NARCIS (Netherlands)

    Levi, Marcel; de Jonge, Evert; van der Poll, Tom

    2004-01-01

    A variety of clinical conditions may cause systemic activation of coagulation, ranging from insignificant laboratory changes to severe disseminated intravascular coagulation (DIC). DIC consists of a widespread, systemic activation of coagulation, resulting in diffuse fibrin deposition in small and

  13. Profound Effect of Profiling Platform and Normalization Strategy on Detection of Differentially Expressed MicroRNAs – A Comparative Study

    Science.gov (United States)

    Meyer, Swanhild U.; Kaiser, Sebastian; Wagner, Carola; Thirion, Christian; Pfaffl, Michael W.

    2012-01-01

    Background Adequate normalization minimizes the effects of systematic technical variations and is a prerequisite for getting meaningful biological changes. However, there is inconsistency about miRNA normalization performances and recommendations. Thus, we investigated the impact of seven different normalization methods (reference gene index, global geometric mean, quantile, invariant selection, loess, loessM, and generalized procrustes analysis) on intra- and inter-platform performance of two distinct and commonly used miRNA profiling platforms. Methodology/Principal Findings We included data from miRNA profiling analyses derived from a hybridization-based platform (Agilent Technologies) and an RT-qPCR platform (Applied Biosystems). Furthermore, we validated a subset of miRNAs by individual RT-qPCR assays. Our analyses incorporated data from the effect of differentiation and tumor necrosis factor alpha treatment on primary human skeletal muscle cells and a murine skeletal muscle cell line. Distinct normalization methods differed in their impact on (i) standard deviations, (ii) the area under the receiver operating characteristic (ROC) curve, (iii) the similarity of differential expression. Loess, loessM, and quantile analysis were most effective in minimizing standard deviations on the Agilent and TLDA platform. Moreover, loess, loessM, invariant selection and generalized procrustes analysis increased the area under the ROC curve, a measure for the statistical performance of a test. The Jaccard index revealed that inter-platform concordance of differential expression tended to be increased by loess, loessM, quantile, and GPA normalization of AGL and TLDA data as well as RGI normalization of TLDA data. Conclusions/Significance We recommend the application of loess, or loessM, and GPA normalization for miRNA Agilent arrays and qPCR cards as these normalization approaches showed to (i) effectively reduce standard deviations, (ii) increase sensitivity and accuracy of

  14. Urinary coagulation-fibrinolysis, kallirein-kinin systems and kininase in cases of preclampsia.

    Science.gov (United States)

    Mutoh, S; Kobayashi, M; Hirata, J; Itoh, N; Maki, M; Komatsu, Y; Yoshida, A; Sasa, H; Kuroda, K; Kikuchi, Y

    1992-01-01

    Urinary kallikrein and kallikrein activity significantly decreased in cases of preeclampsia (u-kall./CRE.index 42.39 +/- 9.66 ng/mg, u-kall. act./CRE.index 0.26 +/- 0.06 ng/min/mg), and urinary kininase II and kininase activity significantly increased (u-kininase/CRE.index 10.91 +/- 1.26 x 10(-3) IU/min/mg, u-kininase act./CRE.index 506.37 +/- 178.45 pg/min/mg) when compared with those of normal gravidas from 28 weeks to 42 weeks of gestation (u-kall./CRE.index 189.31 +/- 14.17 ng/mg, u-kall. act./CRE index 1.08 +/- 0.10 ng/min/mg, u-kininase/CRE.index 6.24 +/- 0.31 x 10(-3) IU/min/mg, u-kininase act./CRE.index 15.64 +/- 0.10 pg/min/mg). Urinary FPA, B beta 5-42, alpha 2-PI, and alpha 2PI-plasmin-complex (PIC) significantly increased in preeclampsia (u-FPA/CRE.index 23.59 +/- 8.47 ng/mg, u-B beta/CRE.index 105.26 +/- 29.30 ng/mg, u-alpha 2PI/CRE.index 121.53 +/- 43.57 ng/mg, u-PIC/CRE index 278.39 +/- 60.50 ng/mg) when compared with those of normal control group (u-FPA/CRE.index 0.92 +/- 0.04 ng/mg, u-B beta/CRE.index 12.15 +/- 0.44 ng/mg, u-alpha 2PI/CRE.index 4.18 +/- 0.33 ng/mg, u-PIC/CRE.index 5.98 +/- 1.15 ng/mg). Urinary urokinase markedly increased and urinary D-dimer was detected in severe cases of preeclampsia (u-UK/CRE.index 58.20 +/- 43.69 ng/mg, u-D-dimer 54.76 +/- 9.89 ng/ml) when compared with those of normal control group. These findings suggest that deficiency in urinary kinin excretion may induce hypertension in addition to the changes of urinary coagulation-fibrinolysis system that represents the occurrence of either the endothelial cell injury in the glomerulus or the renal tulbular damage in mild cases of preeclampsia, eventually resulting in the intra-renal vascular coagulation.

  15. [Coagulation factor VII levels in uremic patients and theirs influence factors].

    Science.gov (United States)

    Fang, Jun; Xia, Ling-Hui; Wei, Wen-Ning; Song, Shan-Jun

    2004-12-01

    This study was aimed to investigate coagulation factor VII level in uremic patients with chronic renal failure and to explore theirs influence factors. The plasma levels of coagulation factor VII were detected in 30 uremic patients with chronic renal failure before and after hemodialysis for 1 month, the factor VII activity (FVII:C) was determined by one-stage coagulation method, while activated factor VII (FVIIa) was measured by one-stage coagulation method using recombinant soluble tissue factor, and factor VII antigen was detected by ELISA. The results showed that: (1) The FVIIa, FVII:C and FVIIAg levels in chronic uremic patients before hemodialysis were 4.00 +/- 0.86 microg/L, (148.5 +/- 40.4)% and (99.8 +/- 21.1)% respectively, which were significantly increased, as compared with healthy controls [2.77 +/- 1.02 microg/L, (113.1 +/- 33.0)% and (73.7 +/- 18.3)% respectively, P factor VII was positively correlated with levels of blood uria nitrogen and serum creatinine before hemodialysis but not after hemodialysis. It is concluded that the enhanced levels of coagulation factor VII in chronic uremic patients suggested abnormal activated state, herperactivity and elevated production of factor VII which correlated with renal functional injury. The abnormality of factor VII in uremia may be aggravated by hemodialysis. Coagulation factor (FVII) may be a risk factor for cardiovascular events in uremic patients who especially had been accepted long-term hemodialysis.

  16. Removal of total suspended solid by natural coagulant derived from cassava peel waste

    Science.gov (United States)

    Mohd-Asharuddin, S.; Othman, N.; Mohd-Zin, N. S.; Tajarudin, H. A.

    2018-04-01

    The present study was aimed to investigate the performance of starch derived from cassava peel waste as primary coagulant and coagulant aid. Comparable study was also conducted using commercially used aluminium sulfate (alum) as primary coagulant. A series of Jar tests were performed using raw water from Sembrong Barat water treatment plant. It was observed that coagulation test using cassava peel starch (CPS) alone had unappreciable removing ability. However, it was found that combination of alum-CPS successfully achieve up to 90.48% of total suspended solid (TSS) removal under optimized working conditions (pH 9, 7.5mg/L : 100 mg/L of alum : CPS dosage, rapid mixing of 200 rpm for 1 minute; 100 rpm for 2 minutes, slow mixing of 25 rpm for 30 minutes and 30 minutes settling time). This remarks the reduction in alum dosage up to 50% compared to coagulation test using alum alone. Therefore this finding suggesting that CPS can be considered as potential source of sustainable and effective coagulant aid for water treatment especially in developing countries.

  17. Effects of pentastarch and albumin infusion on cardiorespiratory function and coagulation in patients with severe sepsis and systemic hypoperfusion.

    Science.gov (United States)

    Rackow, E C; Mecher, C; Astiz, M E; Griffel, M; Falk, J L; Weil, M H

    1989-05-01

    Twenty consecutive patients with severe sepsis were randomized to fluid challenge with 5% albumin or 10% low MW hydroxyethyl starch (pentastarch) solutions. Fluid challenge was administered iv as 250 ml of test colloid every 15 min until the pulmonary artery wedge pressure (WP) was greater than or equal to 15 mm Hg or a maximum dose of 2000 ml was infused. Hemodynamic, respiratory, and coagulation profiles were measured before and after fluid infusion. The amount of colloid required to achieve a WP of 15 mm Hg was comparable between groups. Both colloid infusions resulted in similar increases in cardiac output, stroke output, and stroke work. The effect of fluid infusion with pentastarch on coagulation was not significantly different from albumin, although pentastarch was associated with a 45% decrease in factor VIII:c. We conclude that pentastarch is equivalent to albumin for fluid resuscitation of patients with severe sepsis.

  18. Molecular cloning, characterization and expression analysis of coagulation factor VII gene in grass carp (Ctenopharyngodon idella).

    Science.gov (United States)

    Liu, Qiaolin; Xu, Baohong; Xiao, Tiaoyi; Su, Jianming; Zhong, Lei

    2013-08-01

    Coagulation factor VII has been studied in several species but, to date, not in grass carp (Ctenopharyngodon idella), a commercially important freshwater fish found in China. In this study, the full-length cDNA of grass carp coagulation factor VII (GcCFVII) was cloned using a RACE-Ready cDNA Kit, grass carp were challenged with a hemorrhagic virus, and temporal expression profiles of GcCFVII in the thymus, gills, liver, spleen, and head kidney were examined at 0 h, 24 h, 48 h, 72 h, 96 h, and 138 h using fluorescence quantitative PCR. The results showed the 1480 bp GcCFVII to contain three conservative motifs: Gla, EGF-CA, and Tryp-SPc, similar to other species. Phylogenetic analysis showed the evolution of GcCFVII gene to be consistent with the evolution of the species. After viral challenge, GcCFVII expression in five tissues of grass carp showed different patterns of fluctuation. These results provide a solid basis for further investigation of GcCFVII and its relationship with grass carp hemorrhage. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Acute kidney injury and disseminated intravascular coagulation due to mercuric chloride poisoning

    Directory of Open Access Journals (Sweden)

    J Dhanapriya

    2016-01-01

    Full Text Available Mercury is a toxic heavy metal and occurs in organic and inorganic forms. Inorganic mercury includes elemental mercury and mercury salts. Mercury salts are usually white powder or crystals, and widely used in indigenous medicines and folk remedies in Asia. Inorganic mercury poisoning causes acute kidney injury (AKI and gastrointestinal manifestations and can be life-threatening. We describe a case with unknown substance poisoning who developed AKI and disseminated intravascular coagulation (DIC. Renal biopsy showed acute tubular necrosis. Later, the consumed substance was proven to be mercuric chloride. His renal failure improved over time, and his creatinine normalized after 2 months.

  20. Causes and consequences of coagulation activation in sepsis: an evolutionary medicine perspective.

    Science.gov (United States)

    Fiusa, Maiara Marx Luz; Carvalho-Filho, Marco Antonio; Annichino-Bizzacchi, Joyce M; De Paula, Erich V

    2015-05-06

    Coagulation and innate immunity have been linked together for at least 450 million years of evolution. Sepsis, one of the world's leading causes of death, is probably the condition in which this evolutionary link is more evident. However, the biological and the clinical relevance of this association have only recently gained the attention of the scientific community. During sepsis, the host response to a pathogen is invariably associated with coagulation activation. For several years, coagulation activation has been solely regarded as a mechanism of tissue damage, a concept that led to several clinical trials of anticoagulant agents for sepsis. More recently, this paradigm has been challenged by the failure of these clinical trials, and by a growing bulk of evidence supporting the concept that coagulation activation is beneficial for pathogen clearance. In this article we discuss recent basic and clinical data that point to a more balanced view of the detrimental and beneficial consequences of coagulation activation in sepsis. Reappraisal of the association between coagulation and immune activation from an evolutionary medicine perspective offers a unique opportunity to gain new insights about the pathogenesis of sepsis, paving the way to more successful approaches in both basic and clinical research in this field.

  1. Pretreatment of wastewater: Optimal coagulant selection using Partial Order Scaling Analysis (POSA)

    International Nuclear Information System (INIS)

    Tzfati, Eran; Sein, Maya; Rubinov, Angelika; Raveh, Adi; Bick, Amos

    2011-01-01

    Jar-test is a well-known tool for chemical selection for physical-chemical wastewater treatment. Jar test results show the treatment efficiency in terms of suspended matter and organic matter removal. However, in spite of having all these results, coagulant selection is not an easy task because one coagulant can remove efficiently the suspended solids but at the same time increase the conductivity. This makes the final selection of coagulants very dependent on the relative importance assigned to each measured parameter. In this paper, the use of Partial Order Scaling Analysis (POSA) and multi-criteria decision analysis is proposed to help the selection of the coagulant and its concentration in a sequencing batch reactor (SBR). Therefore, starting from the parameters fixed by the jar-test results, these techniques will allow to weight these parameters, according to the judgments of wastewater experts, and to establish priorities among coagulants. An evaluation of two commonly used coagulation/flocculation aids (Alum and Ferric Chloride) was conducted and based on jar tests and POSA model, Ferric Chloride (100 ppm) was the best choice. The results obtained show that POSA and multi-criteria techniques are useful tools to select the optimal chemicals for the physical-technical treatment.

  2. Arsenic removal by coagulation using ferric chloride and chitosan from water

    Directory of Open Access Journals (Sweden)

    Farid Hesami

    2013-01-01

    Conclusions: Chitosan as natural coagulant aid improved arsenic removal efficiency by coagulation process using FeCl 3 . This method can be used for regions with drinking water contaminated with initial arsenic concentration less than 1 000 μg/l.

  3. Evaluation of Moringa oleifera seed as coagulation aid for treatment ...

    African Journals Online (AJOL)

    Laboratory tests were carried out to evaluate the potentials of Moringa oleifera seed powder as a coagulation aid for removal of suspended particles in fish culture effluent. The standard jar test was used to investigate the dosage and mixing intensity required to optimize the use of the coagulant in removing of suspended ...

  4. Coagulation of sheep intestinal and prefemoral lymph.

    Science.gov (United States)

    Hanley, C A; Johnston, M G; Nelson, W

    1988-06-01

    We have determined the most suitable method for the automated analysis of the clotting parameters in sheep intestinal and prefemoral lymph as defined by the Activated Partial Thromboplastin Times (APTT; measure of intrinsic coagulation pathway) and the Prothrombin Times (PT; measure of extrinsic coagulation pathway). As opposed to optical density systems, the use of a Fibro-System Fibrometer was found to provide the most consistent assessment of coagulation with the endpoint being the time to fibrin strand formation. We measured APTT in sheep intestinal and prefemoral lymph of 59.78 +/- 7.69 seconds and 51.03 +/- 10.49 seconds respectively. These values were more prolonged than those obtained from sheep blood plasma but only in the case of intestinal lymph were the differences significant (p less than 0.025). Human blood APTT values were significantly less than both sheep blood (p less than 0.05) and sheep intestinal (p less than 0.001) and prefemoral lymph (p less than 0.01). PT values were found to be 21.56 +/- 1.14 seconds in intestinal and 22.00 +/- 1.88 seconds in prefemoral lymph. These values were also significantly greater than those obtained from sheep blood (both p less than 0.001). Human blood PTs were significantly less than both sheep blood (p less than 0.001) and intestinal and prefemoral lymph (both p less than 0.001). Measurement of APTT and PT values in intestinal lymph and PT determinations in prefemoral lymph were not affected by storage in the refrigerator or freezer. There was some indication that APTT values in prefemoral samples were susceptible to storage artifacts; however, the differences in coagulation times were not significant.

  5. Low-cost multi-stage filtration enhanced by coagulation-flocculation in upflow gravel filtration

    Directory of Open Access Journals (Sweden)

    L. D. Sánchez

    2012-12-01

    Full Text Available This paper assesses the operational and design aspects of coagulation and flocculation in upflow gravel filters (CF-UGF in a multi-stage filtration (MSF plant. This study shows that CF-UGF units improve the performance of MSF considerably, when the system operates with turbidity above 30 NTU. It strongly reduces the load of particulate material before the water enters in the slow sand filters (SSF and therewith avoids short filter runs and prevents early interruption in SSF operations. The removal efficiency of turbidity in the CF-UGF with coagulant was between 85 and 96%, whereas the average efficiency without coagulant dosing was 46% (range: 21–76%. Operating with coagulant also improves the removal efficiency for total coliforms, E-coli and HPC. No reduction was observed in the microbial activity of the SSF, no obstruction of the SSF bed was demonstrated and SSF runs were maintained between 50 and 70 days for a maximum head loss of 0.70 m. The most important advantage is the flexibility of the system to operate with and without coagulant according to the influent turbidity. It was only necessary for 20% of the time to operate with the coagulant. The CF-UGF unit represented 7% of total construction costs and the O&M cost for the use of coagulant represented only 0.3%.

  6. Performance optimization of coagulant/flocculant in the treatment of wastewater from a beverage industry.

    Science.gov (United States)

    Amuda, O S; Amoo, I A; Ajayi, O O

    2006-02-28

    This study investigated the effect of coagulation/flocculation treatment process on wastewater of Fumman Beverage Industry, Ibadan, Nigeria. The study also compared different dosages of coagulant, polyelectrolyte (non-ionic polyacrylamide) and different pH values of the coagulation processes. The effect of different dosages of polyelectrolyte in combination with coagulant was also studied. The results reveal that low pH values (3-8), enhance removal efficiency of the contaminants. Percentage removal of 78, 74 and 75 of COD, TSS and TP, respectively, were achieved by the addition of 500 mg/L Fe2(SO4)3.3H2O and 93, 94 and 96% removal of COD, TSS and TP, respectively, were achieved with the addition of 25 mg/L polyelectrolyte to the coagulation process. The volume of sludge produced, when coagulant was used solely, was higher compared to the use of polyelectrolyte combined with Fe2(SO4)3.3H2O. This may be as a result of non-ionic nature of the polyelectrolyte; hence, it does not chemically react with solids of the wastewater. Coagulation/flocculation may be useful as a pre-treatment process for beverage industrial wastewater prior to biological treatment.

  7. Inhibitory Effect of Triterpenoids from Panax ginseng on Coagulation Factor X

    Directory of Open Access Journals (Sweden)

    Lingxin Xiong

    2017-04-01

    Full Text Available Enzymes involved in the coagulation process have received great attention as potential targets for the development of oral anti-coagulants. Among these enzymes, coagulation factor Xa (FXa has remained the center of attention in the last decade. In this study, 16 ginsenosides and two sapogenins were isolated, identified and quantified. To determine the inhibitory potential on FXa, the chromogenic substrates method was used. The assay suggested that compounds 5, 13 and 18 were mainly responsible for the anti-coagulant effect. Furthermore, these three compounds also possessed high thrombin selectivity in the thrombin inhibition assay. Furthermore, Glide XP from Schrödinger was employed for molecular docking to clarify the interaction between the bioactive compounds and FXa. Therefore, the chemical and biological results indicate that compounds 5 (ginsenoside Rg2, 13 (ginsenoside Rg3 and 18 (protopanaxtriol, PPT are potential natural inhibitors against FXa.

  8. Interpretation of coagulation test results using a web-based reporting system.

    Science.gov (United States)

    Quesada, Andres E; Jabcuga, Christine E; Nguyen, Alex; Wahed, Amer; Nedelcu, Elena; Nguyen, Andy N D

    2014-01-01

    Web-based synoptic reporting has been successfully integrated into diverse fields of pathology, improving efficiency and reducing typographic errors. Coagulation is a challenging field for practicing pathologists and pathologists-in-training alike. To develop a Web-based program that can expedite the generation of a individualized interpretive report for a variety of coagulation tests. We developed a Web-based synoptic reporting system composed of 119 coagulation report templates and 38 thromboelastography (TEG) report templates covering a wide range of findings. Our institution implemented this reporting system in July 2011; it is currently used by pathology residents and attending pathologists. Feedback from the users of these reports have been overwhelmingly positive. Surveys note the time saved and reduced errors. Our easily accessible, user-friendly, Web-based synoptic reporting system for coagulation is a valuable asset to our laboratory services. Copyright© by the American Society for Clinical Pathology (ASCP).

  9. Characterisation of landfill leachate by EEM-PARAFAC-SOM during physical-chemical treatment by coagulation-flocculation, activated carbon adsorption and ion exchange.

    Science.gov (United States)

    Oloibiri, Violet; De Coninck, Sam; Chys, Michael; Demeestere, Kristof; Van Hulle, Stijn W H

    2017-11-01

    The combination of fluorescence excitation-emission matrices (EEM), parallel factor analysis (PARAFAC) and self-organizing maps (SOM) is shown to be a powerful tool in the follow up of dissolved organic matter (DOM) removal from landfill leachate by physical-chemical treatment consisting of coagulation, granular activated carbon (GAC) and ion exchange. Using PARAFAC, three DOM components were identified: C1 representing humic/fulvic-like compounds; C2 representing tryptophan-like compounds; and C3 representing humic-like compounds. Coagulation with ferric chloride (FeCl 3 ) at a dose of 7 g/L reduced the maximum fluorescence of C1, C2 and C3 by 52%, 17% and 15% respectively, while polyaluminium chloride (PACl) reduced C1 only by 7% at the same dose. DOM removal during GAC and ion exchange treatment of raw and coagulated leachate exhibited different profiles. At less than 2 bed volumes (BV) of treatment, the humic components C1 and C3 were rapidly removed, whereas at BV ≥ 2 the tryptophan-like component C2 was preferentially removed. Overall, leachate treated with coagulation +10.6 BV GAC +10.6 BV ion exchange showed the highest removal of C1 (39% - FeCl 3 , 8% - PACl), C2 (74% - FeCl 3 , 68% - PACl) and no C3 removal; whereas only 52% C2 and no C1 and C3 removal was observed in raw leachate treated with 10.6 BV GAC + 10.6 BV ion exchange only. Analysis of PARAFAC-derived components with SOM revealed that coagulation, GAC and ion exchange can treat leachate at least 50% longer than only GAC and ion exchange before the fluorescence composition of leachate remains unchanged. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Comparison of the level of residual coagulant activity in different cheese varieties.

    Science.gov (United States)

    Bansal, Nidhi; Fox, Patrick F; McSweeney, Paul L H

    2009-08-01

    The coagulant retained in cheese curd is a major contributor to proteolysis during ripening. The objective of this study was to quantify residual coagulant in 9 cheese varieties by measuring its activity on a synthetic heptapeptide (Pro-Thr-Glu-Phe-[NO2-Phe]-Arg-Leu) assayed using reversed-phase HPLC. The level of residual coagulant activity was highest in Camembert cheese, probably due to its low pH at whey drainage and the high moisture content of the cheese, followed in order by Feta=Port du Salut=Cheddar>Gouda>Emmental=Parmigiano Reggiano=low-moisture part-skim Mozzarella=Mozzarella di Bufala Campana. The high cooking temperature (50-54 degrees C) used during the manufacture of Emmental and Parmigiano Reggiano cheeses and the cooking and stretching step in hot water during the manufacture of Mozzarella cheese may be the reasons for the lowest residual coagulant activity in these cheeses. The level of residual coagulant activity was higher in Feta cheese made from milk concentrated by ultrafiltration than in conventional Feta.

  11. Characteristics of BPA removal from water by PACl-Al13 in coagulation process.

    Science.gov (United States)

    Xiaoying, Ma; Guangming, Zeng; Chang, Zhang; Zisong, Wang; Jian, Yu; Jianbing, Li; Guohe, Huang; Hongliang, Liu

    2009-09-15

    This paper discussed the coagulation characteristics of BPA with polyaluminum chloride (PACl-Al(13)) as coagulant, examined the impact of coagulation pH, PACl-Al(13) dosage, TOC (total organic carbon) and turbidity on BPA removal, and analyzed the possible dominant mechanisms in water coagulation process. Formation and performance of flocs during coagulation processes were monitored using photometric dispersion analyzer (PDA). When the concentration of humic acid matters and turbidity was low in the solution, the experimental results showed that the removal of BPA experienced increase and subsequently decrease with the PACl-Al(13) dosage increasing. The optimal PACl-Al(13) dosage was found at BPA/PACl-Al(13)=1:2.6(M/M) under our experiment conditions. Results show that the maximum BPA removal efficiency occurred at pH 9.0 due to the adsorption by Al(13) aggregates onto BPA rather than charge neutralization mechanism by polynuclear aluminous salts in the solution. The humic acid matters and kaolin in the solution have significant effect on BPA removal with PACl-Al(13) in the coagulation. The BPA removal will be weakened at high humic matters. The removal rate of BPA increased and subsequently decreased with the turbidity increasing.

  12. Effects of storage conditions of Moringa oleifera seeds on its performance in coagulation.

    Science.gov (United States)

    Katayon, S; Noor, M J Megat Mohd; Asma, M; Ghani, L A Abdul; Thamer, A M; Azni, I; Ahmad, J; Khor, B C; Suleyman, A M

    2006-09-01

    Moringa oleifera is a plant whose seeds have coagulation properties for treating water and wastewater. In this study the coagulation efficiency of Moringa oleifera kept in different storage conditions were studied. The Moringa oleifera seeds were stored at different conditions and durations; open container and closed container at room temperature (28 degrees C) and refrigerator (3 degrees C) for durations of 1, 3 and 5 months. Comparison between turbidity removal efficiency of Moringa oleifera kept in refrigerator and room temperature revealed that there was no significant difference between them. The Moringa oleifera kept in refrigerator and room temperature for one month showed higher turbidity removal efficiency, compared to those kept for 3 and 5 months, at both containers. The coagulation efficiency of Moringa oleifera was found to be dependent on initial turbidity of water samples. Highest turbidity removals were obtained for water with very high initial turbidity. In summary coagulation efficiency of Moringa oleifera was found independent of storage temperature and container, however coagulation efficiency of Moringa oleifera decreased as storage duration increased. In addition, Moringa oleifera can be used as a potential coagulant especially for very high turbidity water.

  13. Application of Moringa Oleifera Seed Powder for Iron (III) Coagulation on Local Water Resources

    OpenAIRE

    Prasetyaningtyas, Fadillah Utami; Rumhayati, Barlah; Masruri, Masruri

    2013-01-01

    This research aims to know the effect of the use of powder moringa seed to coagulant mass and coagulation process, and its effectiveness to increase the quality of pure water. This research uses factorial research design and statistic test MANOVA. To analyse water quality, the researcher uses Fe parameter.  A graphic of coagulant mass and time for each parameter is used to analyse the data. Based on the research result, the uses of moringa seed as coagulant in each 300 mL mineral water gives ...

  14. Diffusion mediated coagulation and fragmentation based study of domain formation in lipid bilayer membrane

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Laxminarsimha V., E-mail: laxman@iitk.ac.in [Mechanics and Applied Mathematics Group, Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur 208016 (India); Roy, Subhradeep [Department of Biomedical Engineering and Mechanics (MC 0219), Virginia Tech, 495 Old Turner Street, Blacksburg, VA 24061 (United States); Das, Sovan Lal [Mechanics and Applied Mathematics Group, Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur 208016 (India)

    2017-01-15

    We estimate the equilibrium size distribution of cholesterol rich micro-domains on a lipid bilayer by solving Smoluchowski equation for coagulation and fragmentation. Towards this aim, we first derive the coagulation kernels based on the diffusion behaviour of domains moving in a two dimensional membrane sheet, as this represents the reality better. We incorporate three different diffusion scenarios of domain diffusion into our coagulation kernel. Subsequently, we investigate the influence of the parameters in our model on the coagulation and fragmentation behaviour. The observed behaviours of the coagulation and fragmentation kernels are also manifested in the equilibrium domain size distribution and its first moment. Finally, considering the liquid domains diffusing in a supported lipid bilayer, we fit the equilibrium domain size distribution to a benchmark solution.

  15. Blood coagulation and fibrinolysis of the whole-body irradiated rabbits

    International Nuclear Information System (INIS)

    Hishikawa-Itoh, Youko; Ayakawa, Yoshio; Miyata, Nobuki

    1984-01-01

    To study the effects of irradiation on blood coagulation and fibrinolysis, rabbits were irradiated with 60 Co γ-rays (whole-body: 0, 100, 400, 800, 1200 rads). Clotting time, activity of plasmin and plasminogen, and fibrinogen contents of irradiated rabbit plasma were measured at 4 days before, immediately after, and at 1, 3, 7, 10, and 14 days after irradiation. Both clotting times obtained by addition of (kaolin+phospholipid) which expressed effects on the total intrinsic coagulation system, and by addition of (Ca 2+ ) which expressed effects on the total extrinsic coagulation system, were prolonged with small dose irradiation (100 rads) immediately and 3 days after irradiation. However, with high dose irradiation (400-1200 rads), these clotting times were prolonged 1 day after irradiation. The times of manifestation of irradiation effects on clotting time were different in small and high dose irradiation. Plasmin activity was decreased immediately, 1 day after and recovered 3 days after irradiation. Plasminogen activity was markedly increased in 800 and 1200 rads irradiated groups from 3 days after irradiation. Conversion of plasminogen into plasmin was impaired by irradiation. Fibrinogen contents increased rapidly in all irradiated rabbits except for 100 rads from 1 day after irradiation. These results revealed decreased coagulation and fibrinolysis activities in rabbit blood, irradiation injury of both coagulation and fibrinolysis activation systems, and accumulation of the precursors of fibrin and plasmin (i.e., fibrinogen and plasminogen). (author)

  16. Effect of fibrinogen on blood coagulation detected by optical coherence tomography

    International Nuclear Information System (INIS)

    Xu, Xiangqun; Teng, Xiangshuai

    2015-01-01

    Our previous work demonstrated that an optical coherence tomography (OCT) technique and the parameter 1/e light penetration depth (d 1/e ) were able to characterize the whole blood coagulation process in contrast to existing optical tests that are performed on plasma samples. To evaluate the feasibility of the technique for quantifying the effect of fibrinogen (Fbg) on blood coagulation, a dynamic study of d 1/e of blood in various Fbg concentrations was performed in static state. Two groups of blood samples of hematocrit (HCT) in 35, 45, and 55% were reconstituted of red blood cells with: 1) treated plasma with its intrinsic Fbg removed and commercial Fbg added (0–8 g L −1 ); and 2) native plasma with commercial Fbg added (0–8 g L −1 ). The results revealed a typical behavior due to coagulation induced by calcium ions and the clotting time is Fbg concentration-dependent. The clotting time was decreased by the increasing amount of Fbg in both groups. Besides, the blood of lower HCT with various levels of Fbg took shorter time to coagulate than that of higher HCT. Consequently, the OCT method is a useful and promising tool for the detection of blood-coagulation processes induced with different Fbg levels. (paper)

  17. Chemical coagulants and Moringa oleifera seed extract for treating concrete wastewater

    Directory of Open Access Journals (Sweden)

    Heber Martins de Paula

    2016-01-01

    Full Text Available Wastewater from concrete plants has a high pH and a high concentration of suspended solids, necessitating treatment before reuse or discharge into the environment. The objective of this study is to evaluate the efficiency of two chemical coagulants, aluminum sulfate (Al2(SO43 and iron chloride (FeCl3, and a natural coagulant, Moringa oleifera (MO, all in their soluble forms, in the treatment of wastewater from concrete plants. To this end, the efficiencies of the three coagulants, in combinations with different proportions, were tested. The quality parameters of the wastewater obtained after the treatments were compared to the limit values for non-potable water. The use of coagulants in their soluble form potentiates their effect, especially when preparing the MO extract, i.e., greater amounts of the protein responsible for the coagulation is extracted. A mixture with MO and Al2(SO43 in a 20:80 proportion showed the best results, with 97.5% of the turbidity removed at 60 min. of sedimentation, allowing the treated water to be used for washing vehicles and flushing toilets. The FeCl3 treatment produced a high concentration of chlorides, which could cause corrosion problems, and is therefore not recommended for concrete wastewater treatment.

  18. Comparing cancer vs normal gene expression profiles identifies new disease entities and common transcriptional programs in AML patients

    DEFF Research Database (Denmark)

    Rapin, Nicolas; Bagger, Frederik Otzen; Jendholm, Johan

    2014-01-01

    Gene expression profiling has been used extensively to characterize cancer, identify novel subtypes, and improve patient stratification. However, it has largely failed to identify transcriptional programs that differ between cancer and corresponding normal cells and has not been efficient in iden......-karyotype AML, which allowed for the generation of a highly prognostic survival signature. Collectively, our CvN method holds great potential as a tool for the analysis of gene expression profiles of cancer patients....

  19. Aqueous arsenite removal by simultaneous ultraviolet photocatalytic oxidation-coagulation of titanium sulfate

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yuxia [Key Laboratory of Northwest Water Resources, Environment and Ecology, MOE, School of Environmental & Municipal Engineering, Xi’an University of Architecture and Technology (China); Duan, Jinming, E-mail: jinmingduan@xauat.edu.cn [Key Laboratory of Northwest Water Resources, Environment and Ecology, MOE, School of Environmental & Municipal Engineering, Xi’an University of Architecture and Technology (China); Centre for Water Management and Reuse, School of Natural and Built Environments, University of South Australia, Mawson Lakes Campus, South Australia (Australia); Li, Wei [Key Laboratory of Northwest Water Resources, Environment and Ecology, MOE, School of Environmental & Municipal Engineering, Xi’an University of Architecture and Technology (China); Beecham, Simon; Mulcahy, Dennis [Centre for Water Management and Reuse, School of Natural and Built Environments, University of South Australia, Mawson Lakes Campus, South Australia (Australia)

    2016-02-13

    Highlights: • A simultaneous UV catalysed oxidation–coagulation for As(III) removal is proposed. • As(III) was effectively oxidised to As(V) by the UV catalysed coagulation. • >99% removal for As(III) in pH 4–6 at low doses of Ti(SO{sub 4}){sub 2} was achieved. • Concurrent UV radiation in massive small crystal formation facilitate the effects. • Reaction mechanisms involve both hydroxyl radicals and superoxide radicals. - Abstract: This study explored the efficacy and efficiency of a simultaneous UV-catalyzed oxidation–coagulation process of titanium sulfate (UV/Ti(SO{sub 4}){sub 2}) for efficient removal of As(III) from water. It revealed that, As(III) could be oxidized to As(V) during the UV catalyzed coagulation of Ti(SO{sub 4}){sub 2} with highly efficient As(III) removal in the pH range 4–6{sub .} The UV catalyzed oxidation–coagulation showed surprisingly effective oxidation of As(III) to As(V) within a short time. XPS indicated that 84.7% of arsenic on the coagulated precipitate was in the oxidized form of As(V) after the UV/Ti(SO{sub 4}){sub 2} treatment of As(III) aqueous solutions at pH 5. Arsenic remaining in solution at high pH was in the oxidized form As(V). Removal efficiencies of As(III) were investigated as a function of pH, Ti(SO{sub 4}){sub 2} dosage, initial As(III) concentration and irradiation energy. As(III) could almost completely be removed (>99%) by the photocatalytic oxidation–coagulation process with a moderate dose of Ti(SO{sub 4}){sub 2} in the pH range 4–6 at an initial arsenic concentration of 200 μg/L. The mechanisms of the photocatalytic coagulation oxidation of Ti(SO{sub 4}){sub 2} are similar to those of UV/crystalline TiO{sub 2} particles, involving the formation and reactions of the hydroxyl radical OH· and superoxide HO{sub 2}·/O{sub 2}{sup ·−}.

  20. Effects of long-term head-down-tilt bed rest and different training regimes on the coagulation system of healthy men.

    Science.gov (United States)

    Haider, Thomas; Gunga, Hanns-Christian; Matteucci-Gothe, Raffaella; Sottara, Elke; Griesmacher, Andrea; Belavý, Daniel L; Felsenberg, Dieter; Werner, Andreas; Schobersberger, Wolfgang

    2013-11-01

    Immobility plus preexisting chronic disease or acute trauma can activate the coagulation system, thus increasing the risk for thromboembolic events. The effects of long-term bed-rest immobility and microgravity on the coagulation system of healthy persons (e.g., during crewed Mars missions) have not yet been studied. The main objective of the second Berlin BedRest Study (BBR2-2) "Coagulation Part" was to investigate adaptations of the hemostatic system during long-term bed rest (60 days) under simulated microgravity (6° head-down-tilt [6°HDT]) and after mobilization in three different volunteer groups (randomly assigned to CTR= inactive control group; RE= resistive exercise only group; and RVE= resistive exercise with whole-body vibration group). In 24 males (aged 21-45 years), before, during, and after long-term bed rest, key parameters of coagulation were measured from venous blood samples: D-dimer (DD), thrombin-antithrombin III complex (TAT), and prothrombin fragment F1 + 2 (PT-F1 + 2). Additionally, modified rotational thrombelastometry (ROTEM (®) ) analysis was performed. Times of exploratory analyses were as follows: baseline data collection 2 days before bed rest (BDC-2); eight different days of 6°HDT bed rest (HDT1-HDT60), and two different days after reambulation (R + 3 and R + 6). We found significant changes in DD, TAT, and PT-F1 + 2 over the total time course, but no consistent effect of physical interventions (RE, RVE) on these parameters. Notably, no parameter reached levels indicative of intravascular thrombin formation. All ROTEM® parameters remained within the normal range and no pathological traces were found. Sixty days of 6°HDT bed rest are not associated with pronounced activation of the coagulation system indicative of intravascular thrombus formation in healthy volunteers independent of the training type during the bed rest.

  1. Quinine-induced disseminated intravascular coagulation.

    Science.gov (United States)

    Spearing, R L; Hickton, C M; Sizeland, P; Hannah, A; Bailey, R R

    Recurrent disseminated intravascular coagulation occurred in 3 women after ingestion of quinine tablets for cramp. All had circulating quinine-dependent antibodies to platelets and in 2 there was initial evidence of antibody consumption, with low titres that rose steeply over the next few days and remained high for many months.

  2. A natural coagulant protein from Moringa oleifera: isolation, characterization, and potential use for water treatment

    Science.gov (United States)

    Choudhary, Manisha; Neogi, Sudarsan

    2017-10-01

    In developing countries pond water is still widely used for drinking and household purposes, which develops higher turbidity during rainy seasons and requires a large amount of chemical coagulants, and this leads to high cost of treatment. To mitigate this, it is important to find an economical and natural coagulant to treat turbid water. The present study is focused on using a plant based component as a natural coagulant that is sustainable and environment-friendly. This work focuses on the extraction, isolation and purification of a natural coagulant from seed kernels of Moringa oleifera to enhance its turbidity removal efficiency. The determination of themolecular weight of the purified proteins was done using sodium dodecyl sulfate polyacrylamide gel electrophoresis. The active coagulant proteins were isolated using 30-60% and 60-80% saturation of ammonium sulfate. It was observed that proteins with molecular weight less than 36 kDa have superior coagulation activity. Turbidity removal efficiency of these active coagulant proteins was compared with alum. The possibility of using Moringa oleifera seeds as a natural antimicrobial agent was also investigated.

  3. Hibiscus rosa- sinensis leaf extract as coagulant aid in leachate treatment

    Science.gov (United States)

    Awang, Nik Azimatolakma; Aziz, Hamidi Abdul

    2012-12-01

    Hibiscus rosa- sinensis is a biodegradable material that has remained untested for flocculating properties. The objective of this study is to examine the efficiency of coagulation-flocculation processes for the removal of color, iron (Fe3+), suspended solids, turbidity and ammonia nitrogen(NH3-N), from landfill leachate using 4,000 mg/L alum in conjunction with H. rosa- sinensis leaf extract (HBaqs). Hydroxyl (O-H) and (carboxyl) C=O functional groups along the HBaqs chain help to indulge flocculating efficiency of HBaqs via bridging. The experiments confirm the positive coagulation properties of HBaqs. The Fe3+ removal rate using 4,000 mg/L alum as sole coagulant was approximately 60 %, and increased to 100 % when 4,000 mg/L alum was mixed with 500 mg/L HBaqs. By mixing, 4,000 mg/L alum with 100-500 mg/L HBaqs, 72 % of SS was removed as compared with only 45 % reduction using 4,000 mg/L alum as sole coagulant.

  4. Modifications de la coagulation sanguine dans la fièvre jaune

    Directory of Open Access Journals (Sweden)

    J. Vellard

    1929-01-01

    Full Text Available L'étude des modifications de la coagulation sanguine à l'aide de la technique BRAZIL-VELLARD, réalisée chez 25 malades atteints de formes diverses, mortelles, graves, et bénignes, entre le lléme et le XIIIéme jour de maladie, et chez 12 convalescents, a permis d'arriver aux conclusions suivantes: 1º. Les variations du pouvoir coagulant du serum sont très irrégulières et peu différentes des celles observées chez de sujets normaux. 2º. La coagulabilité du plasma, dès le IIème jour de la maladie, présente une diminution marquée, constante chez tous les malades, atteignant son chiffre le plus bas entre le VIIème et le IXème jour et revenant progressivement á la normale pendant la convalescence. 3º. Cette diminution de la coagulabilité est due principalement á l'apparition de grandes quantités d'antithrombines dans la circulation; la diminution du fibrinogène observée dans quelques cas, est toujours peu accusée. 4º. La diminution de la coagulabilité du plasma, qui n'a jusqu'ici été observée avec cette intensité que dans la fièvre jaune, peut être d'un certain secours pour le diagnostic précoce de cette affection; elle n'a jamais été vérifiée chez des malades atteints d'autres affections fébriles. 5º. Au point de vue du pronostic, la diminution précoce et très accentuée de la coagulabilité est un symptôme grave, indiquant une lésion profonde de la cellule hépatique. 6º. Dans la fièvre jaune expérimentale du Macacus rhesus, les altérations de la coagulation sanguine sont de même nature, mais paraissent plus tardives et moins accusées que chez l'homme.

  5. Potential of Hibiscus Sabdariffa and Jatropha Curcas as Natural Coagulants in the Treatment of Pharmaceutical Wastewater

    Directory of Open Access Journals (Sweden)

    Sibartie Sheena

    2018-01-01

    Full Text Available Pharmaceutical wastewater is one of the most difficult wastewater to treat due to the presence of pharmaceutical compounds resulting in high concentration of organic matter, high turbidity and Chemical Oxygen Demand (COD. Chemical-based coagulation is a common method used to treat wastewater. However, the issue that has been raised with the use of chemical coagulants is their presence in water after treatment that can cause risks to the human health such as Alzheimer and cancer. Natural coagulants can be used as a safe alternative to these chemicals instead. Therefore, the objective of this experiment was to study the effect of H. Sabdariffa and J. Curcas as natural coagulants, separately and as a combination, on the treatment of pharmaceutical wastewater. Jar test experiment were carried out where beakers of 0.5L wastewater were mixed with the coagulants. The pH of the wastewater was varied from 2 to 12 while the coagulant dosage was varied from 40 to 200 mg/L. It was found that H. Sabdariffa works best at pH 4 and at a coagulant dosage of 190 mg/L with a highest turbidity removal of 35.8% and a decrease of COD by 29%. J. Curcas was found to perform best at pH 3 and with a coagulant dosage of 200 mg/L with a highest turbidity removal of 51% and a decrease of COD by 32%. When J. Curcas and H. Sabdariffa were used in combination, the optimum composition was found to be 80% J. Curcas and 20% H. Sabdariffa by weight with a maximum turbidity removal of 46.8% and a decrease in COD by 46%. In comparison between the two natural coagulants, J. Curcas is found to be a better and more suited coagulative agent for the treatment of pharmaceutical wastewater. The same experiment was carried with alum at pH 6 and coagulant dosage of 750 mg/L and a turbidity removal of 48% and a decrease in COD by 38% were recorded. In comparison with alum, J. Curcas was a better coagulant in treating the pharmaceutical wastewater. This shows that natural coagulants can be

  6. Exact results for the Boltzmann equation and Smoluchowski's coagulation equation

    International Nuclear Information System (INIS)

    Hendriks, E.M.

    1983-01-01

    Almost no analytical solutions have been found for realistic intermolecular forces, largely due to the complicated structure of the collision term which calls for the construction of simplified models, in which as many physical properties are maintained as possible. In the first three chapters of this thesis such model Boltzmann equations are studied. Only spatially homogeneous gases with isotropic distribution functions are considered. Chapter I considers transition kernels, chapter II persistent scattering models and chapter III very hard particles. The second part of this dissertation deals with Smoluchowski's coagulation equation for the size distribution function in a coagulating system, with chapters devoted to the following topics: kinetics of gelation and universality, coagulation equations with gelation and exactly soluble models of nucleation. (Auth./C.F.)

  7. Disseminated intravascular coagulation in solid tumors

    International Nuclear Information System (INIS)

    Terzieff, V.; Alonso, I.; Vázquez, A.

    2004-01-01

    It is estimated that 20-25% of cases of disseminated intravascular coagulation (DIC) relate to an underlying neoplasia primarily hematologic. It is estimated that about 5% of patients with solid tumors have CID clinic, although the incidence of subclinical alterations is much higher. The CID is not limited to the activation of the coagulation cascade, which leads to bleeding micro thrombosis and consumption of coagulation factors. Solid tumors are frequently associated adenocarcinomas producers mucin (especially gastric), usually in the context of a disseminated disease. The mucin may act as a promoter of the cascade, but probably it is a multi-event. High levels of TNF to produced by the tumor mass and chemotherapy-induced cell lysis have Also linked. Although the bleeding is usually oriented diagnosis, the most frequent cause of death is thrombosis. There are no specific tests for diagnosis. Elevated levels of D-dimer and products oriented fibrinogen degradation diagnosis. No reduction fibrinogen and almost always, one thrombocytopenia consumption. Treatment is complex and there is no consensus on many points. To recover the lost factors for consumption, it is recommended to use fresh frozen plasma and / or washed red blood cells. the heparin anticoagulation low dose is indicated since the disease causal can not be controlled quickly, but should not be initiated if there thrombocytopenia 50.000.El under profuse bleeding can require the use of tranexamic acid or EACA. Acute DIC, the case of our patient, is rare and very serious

  8. Benign intracranial hypertension associated to blood coagulation derangements

    Directory of Open Access Journals (Sweden)

    Niglio Alferio

    2006-12-01

    Full Text Available Abstract Background Benign Intracranial Hypertension (BIH may be caused, at least in part, by intracranial sinus thrombosis. Thrombosis is normally due to derangements in blood coagulation cascade which may predispose to abnormal clotting activation or deficiency in natural inhibitors' control. The aim of the study is to examine the strength of the association between risk factors for thrombosis and BIH. Patients and methods The incidence of prothrombotic abnormalities among a randomly investigated cohort of 17 patients with BIH, was compared with 51 healthy subjects matched for sex, age, body mass index, height and social background. Results The number of subjects with protein C deficiency was significantly higher in patients than in controls (3 vs 1, p Increased plasma levels of prothrombin fragment 1+2, fibrinopeptide A (FPA, and PAI-1 were demonstrated in patients group (5.7 ± 1.15 nM vs 0.45 ± 0.35 nM; 8.7 ± 2.5 ng/mL vs 2.2 ± 1.25 ng/mL; 45.7 ± 12.5 ng/mL vs 8.5 ± 6.7 ng/mL, respectively; p Discussion In agreement with other authors our data suggest a state of hypercoagulability in BIH associated with gene polymorphisms. Our findings also showed that mutations in cardiovascular genes significantly discriminate subjects with a BIH history. The association between coagulation and gene derangements, usually regarded to as cryptogenic, may suggest a possible pathogenetic mechanism in BIH. So, a prothrombotic tendency may exist that would, at least in part, explain some cases of BIH. Although based on a small population, these findings raise the exciting possibility of using these haemostatic factors as markers for selecting high-risk subjects in BIH disease.

  9. Improved intra-array and interarray normalization of peptide microarray phosphorylation for phosphorylome and kinome profiling by rational selection of relevant spots

    Science.gov (United States)

    Scholma, Jetse; Fuhler, Gwenny M.; Joore, Jos; Hulsman, Marc; Schivo, Stefano; List, Alan F.; Reinders, Marcel J. T.; Peppelenbosch, Maikel P.; Post, Janine N.

    2016-01-01

    Massive parallel analysis using array technology has become the mainstay for analysis of genomes and transcriptomes. Analogously, the predominance of phosphorylation as a regulator of cellular metabolism has fostered the development of peptide arrays of kinase consensus substrates that allow the charting of cellular phosphorylation events (often called kinome profiling). However, whereas the bioinformatical framework for expression array analysis is well-developed, no advanced analysis tools are yet available for kinome profiling. Especially intra-array and interarray normalization of peptide array phosphorylation remain problematic, due to the absence of “housekeeping” kinases and the obvious fallacy of the assumption that different experimental conditions should exhibit equal amounts of kinase activity. Here we describe the development of analysis tools that reliably quantify phosphorylation of peptide arrays and that allow normalization of the signals obtained. We provide a method for intraslide gradient correction and spot quality control. We describe a novel interarray normalization procedure, named repetitive signal enhancement, RSE, which provides a mathematical approach to limit the false negative results occuring with the use of other normalization procedures. Using in silico and biological experiments we show that employing such protocols yields superior insight into cellular physiology as compared to classical analysis tools for kinome profiling. PMID:27225531

  10. Enhanced coagulation for turbidity and Total Organic Carbon (TOC) removal from river Kansawati water.

    Science.gov (United States)

    Narayan, Sumit; Goel, Sudha

    2011-01-01

    The objective of this study was to determine optimum coagulant doses for turbidity and Total Organic Carbon (TOC) removal and evaluate the extent to which TOC can be removed by enhanced coagulation. Jar tests were conducted in the laboratory to determine optimum doses of alum for the removal of turbidity and Natural Organic Matter (NOM) from river water. Various other water quality parameters were measured before and after thejar tests and included: UV Absorbance (UVA) at 254 nm, microbial concentrations, TDS, conductivity, hardness, alkalinity, and pH. The optimum alum dose for removal of turbidity and TOC was 20 mg/L for the sample collected in November 2009 and 100 mg/L for the sample collected in March 2010. In both cases, the dose for enhanced coagulation was significantly higher than that for conventional coagulation. The gain in TOC removal was insignificant compared to the increase in coagulant dose required. This is usual for low TOC (TOC need to be tested to demonstrate the effectiveness of enhanced coagulation.

  11. A simple purification and activity assay of the coagulant protein from Moringa oleifera seed.

    Science.gov (United States)

    Ghebremichael, Kebreab A; Gunaratna, K R; Henriksson, Hongbin; Brumer, Harry; Dalhammar, Gunnel

    2005-06-01

    Use of extracts from Moringa oleifera (MO) is of great interest for low-cost water treatment. This paper discusses water and salt extraction of a coagulant protein from the seed, purification using ion exchange, its chemical characteristics, coagulation and antimicrobial properties. The coagulant from both extracts is a cationic protein with pI greater than 9.6 and molecular mass less than 6.5 kDa. Mass spectrometric analysis of the purified water extract indicated that it contained at least four homologous proteins, based on MS/MS peptide sequence data. The protein is thermoresistant and remained active after 5h heat treatment at 95 degrees C. The coagulant protein showed both flocculating and antibacterial effects of 1.1--4 log reduction. With samples of high turbidity, the MO extract showed similar coagulation activity as alum. Cecropin A and MO extract were found to have similar flocculation effects for clay and microorganisms. Simple methods for both the purification and assay of MO coagulating proteins are presented, which are necessary for large-scale water treatment applications.

  12. OPTIMIZATION OF FLOCCULATION PROCESS BY MICROBIAL COAGULANT IN RIVER WATER

    Directory of Open Access Journals (Sweden)

    Fatin Nabilah Murad

    2017-12-01

    Full Text Available The existing process of coagulation and flocculation are using chemicals that known as cationic coagulant such as alum, ferric sulfate, calcium oxide, and organic polymers.  Thus, this study concentrates on optimizing of flocculation process by microbial coagulant in river water. Turbidity and suspended solids are the main constraints of river water quality in Malaysia. Hence, a study is proposed to produce microbial coagulants isolated locally for river water treatment. The chosen microbe used as the bioflocculant producer is Aspergillus niger. The parameters to optimization in the flocculation process were pH, bioflocculant dosage and effluent concentration. The research was done in the jar test process and the process parameters for maximum turbidity removal was validated. The highest flocculating activity was obtained on day seven of cultivation in the supernatant. The optimum pH and bioflocculant dosage for an optimize sedimentation process were between 4-5 and 2-3 mL for 0.3 g/L of effluent concentration respectively. The model was validated by using a river water sample from Sg. Pusu and the result showed that the model was acceptable to evaluate the bioflocculation process.

  13. Removal of chemical oxygen demand from textile wastewater using a natural coagulant

    Energy Technology Data Exchange (ETDEWEB)

    Ramavandi, Bahman [Bushehr University of Medical Sciences, Bushehr (Iran, Islamic Republic of); Farjadfard, Sima [Islamic Azad University, Tehran (Iran, Islamic Republic of)

    2014-01-15

    A biomaterial was successfully synthesized from Plantago ovata by using an FeCl{sub 3}-induced crude extract (FCE). The potential of FCE to act as a natural coagulant was tested for the pretreatment of real textile wastewater. Tests were performed to evaluate the effects of FCE quantity, salt concentration, and wastewater pH on chemical oxygen demand (COD) reduction during a coagulation/flocculation process. Experimental results indicated that the wastewater could be effectively treated by using a coagulation/flocculation process, where the BOD{sub 5}/COD ratio of the effluent was improved to 0.48. A low coagulant dose, 1.5mg/L, achieved a high COD removal percentage, 89%, at operational conditions of neutral pH and room temperature. The experimental data revealed that the maximum COD removal occurred at water pH<8. Increasing the salt promoted the COD removal. The settling and filterability characteristics of the sludge were also studied. Scanning electron microscopy and energy dispersive spectroscopy studies were conducted to determine the sludge structure and composition, respectively. Overall, FCE as an eco-friendly biomaterial was revealed to be a very efficient coagulant and a promising option for the removal of COD from wastewaters.

  14. Metabolic and inflammatory profiles of biomarkers in obesity, metabolic syndrome, and diabetes in a Mediterranean population. DARIOS Inflammatory study.

    Science.gov (United States)

    Fernández-Bergés, Daniel; Consuegra-Sánchez, Luciano; Peñafiel, Judith; Cabrera de León, Antonio; Vila, Joan; Félix-Redondo, Francisco Javier; Segura-Fragoso, Antonio; Lapetra, José; Guembe, María Jesús; Vega, Tomás; Fitó, Montse; Elosua, Roberto; Díaz, Oscar; Marrugat, Jaume

    2014-08-01

    There is a paucity of data regarding the differences in the biomarker profiles of patients with obesity, metabolic syndrome, and diabetes mellitus as compared to a healthy, normal weight population. We aimed to study the biomarker profile of the metabolic risk continuum defined by the transition from normal weight to obesity, metabolic syndrome, and diabetes mellitus. We performed a pooled analysis of data from 7 cross-sectional Spanish population-based surveys. An extensive panel comprising 20 biomarkers related to carbohydrate metabolism, lipids, inflammation, coagulation, oxidation, hemodynamics, and myocardial damage was analyzed. We employed age- and sex-adjusted multinomial logistic regression models for the identification of those biomarkers associated with the metabolic risk continuum phenotypes: obesity, metabolic syndrome, and diabetes mellitus. A total of 2851 subjects were included for analyses. The mean age was 57.4 (8.8) years, 1269 were men (44.5%), and 464 participants were obese, 443 had metabolic syndrome, 473 had diabetes mellitus, and 1471 had a normal weight (healthy individuals). High-sensitivity C-reactive protein, apolipoprotein B100, leptin, and insulin were positively associated with at least one of the phenotypes of interest. Apolipoprotein A1 and adiponectin were negatively associated. There are differences between the population with normal weight and that having metabolic syndrome or diabetes with respect to certain biomarkers related to the metabolic, inflammatory, and lipid profiles. The results of this study support the relevance of these mechanisms in the metabolic risk continuum. When metabolic syndrome and diabetes mellitus are compared, these differences are less marked. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  15. Reincarnation of ancient links between coagulation and complement.

    Science.gov (United States)

    Conway, E M

    2015-06-01

    Throughout evolution, organisms have developed means to contain wounds by simultaneously limiting bleeding and eliminating pathogens and damaged host cells via the recruitment of innate defense mechanisms. Disease emerges when there is unchecked activation of innate immune and/or coagulation responses. A key component of innate immunity is the complement system. Concurrent excess activation of coagulation and complement - two major blood-borne proteolytic pathways - is evident in numerous diseases, including atherosclerosis, diabetes, venous thromboembolic disease, thrombotic microangiopathies, arthritis, cancer, and infectious diseases. Delineating the cross-talk between these two cascades will uncover novel therapeutic insights. © 2015 International Society on Thrombosis and Haemostasis.

  16. Surface Potential and Particle Size Effect on the Rate of Perikinetic Coagulation

    International Nuclear Information System (INIS)

    Molina-Bolivar, J. A.; Galisteo-Gonzalez, F.; Cabrerizo-Vilchez, M.; Hidalgo-alvarez, R.

    1998-01-01

    The diffusion-controlled rapid coagulation rate of monodisperse polystyrene particles in aqueous solutions has been measured with a low angle scattering apparatus (nephelometer). We have refined this technique by using a narrow scattering flow cell and a pneumatic addicting-mixing device to introduce the salt solution and the latex sample in the cell. Coagulation rate constants were determined from analysis of the scattered light intensity dependence with time at an angle of 4.5 degree centigrade ± 1 degree centigrade. Experiments were designed to check the effects of particle size, surface potential and counterion valency on rapid coagulation constant. The particle ranged in diameter from 151 nm to 530 nm. The results are compared with the predictions of Smoluchowski's theory. Experiments to obtain the stability diagrams and the critical coagulation concentration of latexes have been performed. (Author) 31 refs

  17. Cerebrospinal fluid biomarkers profile of idiopathic normal pressure hydrocephalus.

    Science.gov (United States)

    Schirinzi, Tommaso; Sancesario, Giulia Maria; Di Lazzaro, Giulia; D'Elia, Alessio; Imbriani, Paola; Scalise, Simona; Pisani, Antonio

    2018-04-01

    Idiopathic normal pressure hydrocephalus (iNPH) is a disabling neurological disorder whose potential treatability is significantly limited by diagnostic uncertainty. In fact, typical clinical presentation occurs at late phases of disease, when CSF shunting could be ineffective. In recent years, measurement of different CSF proteins, whose concentration directly reflects neuropathological changes of CNS, has significantly improved both diagnostic timing and accuracy of neurodegenerative disease. Unfortunately iNPH lacks neuropathological hallmarks allowing the identification of specific disease biomarkers. However, neuropathology of iNPH is so rich and heterogeneous that many processes can be tracked in CSF, including Alzheimer's disease core pathology, subcortical degeneration, neuroinflammation and vascular dysfunction. Indeed, a huge number of CSF biomarkers have been analyzed in iNPH patients, but a unifying profile has not been provided yet. In this brief survey, we thus attempted to summarize the main findings in the field of iNPH CSF biomarkers, aimed at outlining a synthetic model. Although defined cut-off values for biomarkers are not available, a better knowledge of CSF characteristics may definitely assist in diagnosing the disease.

  18. Comparison of single-step and two-step purified coagulants from Moringa oleifera seed for turbidity and DOC removal.

    Science.gov (United States)

    Sánchez-Martín, J; Ghebremichael, K; Beltrán-Heredia, J

    2010-08-01

    The coagulant proteins from Moringa oleifera purified with single-step and two-step ion-exchange processes were used for the coagulation of surface water from Meuse river in The Netherlands. The performances of the two purified coagulants and the crude extract were assessed in terms of turbidity and DOC removal. The results indicated that the optimum dosage of the single-step purified coagulant was more than two times higher compared to the two-step purified coagulant in terms of turbidity removal. And the residual DOC in the two-step purified coagulant was lower than in single-step purified coagulant or crude extract. (c) 2010 Elsevier Ltd. All rights reserved.

  19. Performance of alum and assorted coagulants in turbidity removal of muddy water

    Science.gov (United States)

    Malik, Qasim H.

    2018-03-01

    Coagulation is a primary and cost effective process in water treatment plants. Under optimum conditions, not only it effectively removes turbidity but also results in reduced sludge volume and subsequently minimizes sludge management costs. Highly turbid water from streams, canals, rivers and rain run offs was run through jar test for turbidity removal. The brown water with 250NTU turbidity when coagulated with alum and assorted coagulants proved that maximum turbidity removal was witnessed using alum dose of 0.25 g/l at ph 6 with a sedimentation time of 30 min.

  20. Early markers of blood coagulation and fibrinolysis activation in Argentine hemorrhagic fever

    NARCIS (Netherlands)

    Heller, M. V.; Marta, R. F.; Sturk, A.; Maiztegui, J. I.; Hack, C. E.; Cate, J. W.; Molinas, F. C.

    1995-01-01

    Junin virus, an arenaviridae, is the etiological agent of Argentine hemorrhagic fever. In addition to thrombocytopenia, patients present several alterations in both the blood coagulation and the fibrinolytic system, but diffuse intravascular coagulation could not be demonstrated. To investigate

  1. Is LMWH Sufficient for Anticoagulant Prophylaxis in Bariatric Surgery? Prospective Study.

    Science.gov (United States)

    Moaad, Farraj; Zakhar, Bramnik; Anton, Kvasha; Moner, Merie; Wisam, Sbeit; Safy, Farraj; Igor, Waksman

    2017-09-01

    The objective of this study was to evaluate the coagulation profile by thromboelastography in morbidly obese patients who undergo bariatric surgery. Morbid obesity entails increased risk for thromboembolic events. There is no clear protocol for thromboembolic prophylaxis, regarding timing and length of treatment, in bariatric surgery. Thromboelastography provides data on a coagulation process from creation of the clot until the fibrinolysis. Ninety-three morbidly obese patients were prospectively recruited within a 2-year period. Coagulation profile was measured by thromboelastography before surgery, in the immediate postoperative period, within 3 h from surgery, and in the late postoperative period, within 10-14 days after surgery. Venous thromboembolic prophylaxis was achieved by giving low molecular weight heparin (LMWH), once a day. Of the eligible patients, 67 underwent sleeve gastrectomy while 23 underwent Roux-en-Y gastric bypass. Normal values of coagulation factor function, clotting time, and fibrin function, as measured by R, K, and α (angle), were demonstrated in addition to higher maximal amplitude (MA) values, reflecting increased function of platelets. The average MA value before the surgery was above normal and continued rising consistently in the immediate postoperative as well as in the early postoperative period. Morbidly obese patients have a strong tendency toward thrombosis, as demonstrated by pathologically elevated MA values. Altered coagulation profiles were demonstrated 2 weeks postoperatively; thus, prophylaxis that continued at least for 2 weeks after bariatric surgery should be considered. Since LMW heparin is not sufficient alone as thromboembolic prophylaxis, we recommend adding antiplatelet therapy. Further evaluation of appropriate thromboprophylaxis is warranted.

  2. Matriptase activation connects tissue factor-dependent coagulation initiation to epithelial proteolysis and signaling.

    Science.gov (United States)

    Le Gall, Sylvain M; Szabo, Roman; Lee, Melody; Kirchhofer, Daniel; Craik, Charles S; Bugge, Thomas H; Camerer, Eric

    2016-06-23

    The coagulation cascade is designed to sense tissue injury by physical separation of the membrane-anchored cofactor tissue factor (TF) from inactive precursors of coagulation proteases circulating in plasma. Once TF on epithelial and other extravascular cells is exposed to plasma, sequential activation of coagulation proteases coordinates hemostasis and contributes to host defense and tissue repair. Membrane-anchored serine proteases (MASPs) play critical roles in the development and homeostasis of epithelial barrier tissues; how MASPs are activated in mature epithelia is unknown. We here report that proteases of the extrinsic pathway of blood coagulation transactivate the MASP matriptase, thus connecting coagulation initiation to epithelial proteolysis and signaling. Exposure of TF-expressing cells to factors (F) VIIa and Xa triggered the conversion of latent pro-matriptase to an active protease, which in turn cleaved the pericellular substrates protease-activated receptor-2 (PAR2) and pro-urokinase. An activation pathway-selective PAR2 mutant resistant to direct cleavage by TF:FVIIa and FXa was activated by these proteases when cells co-expressed pro-matriptase, and matriptase transactivation was necessary for efficient cleavage and activation of wild-type PAR2 by physiological concentrations of TF:FVIIa and FXa. The coagulation initiation complex induced rapid and prolonged enhancement of the barrier function of epithelial monolayers that was dependent on matriptase transactivation and PAR2 signaling. These observations suggest that the coagulation cascade engages matriptase to help coordinate epithelial defense and repair programs after injury or infection, and that matriptase may contribute to TF-driven pathogenesis in cancer and inflammation.

  3. Development of a magnetic coagulant based on Moringa oleifera seed extract for water treatment.

    Science.gov (United States)

    Santos, Tássia R T; Silva, Marcela F; Nishi, Leticia; Vieira, Angélica M S; Fagundes-Klen, Márcia R; Andrade, Murilo B; Vieira, Marcelo F; Bergamasco, Rosângela

    2016-04-01

    In this work, to evaluate the effectiveness of the coagulation/flocculation using a natural coagulant, using Moringa oleifera Lam functionalized with magnetic iron oxide nanoparticles, producing flakes that are attracted by an external magnetic field, thereby allowing a fast settling and separation of the clarified liquid, is proposed. The removal efficiency of the parameters, apparent color, turbidity, and compounds with UV254nm absorption, was evaluated. The magnetic functionalized M. oleifera Lam coagulant could effectively remove 90 % of turbidity, 85 % of apparent color, and 50 % for the compounds with absorption at UV254nm, in surface waters under the influence of an external magnetic field within 30 min. It was found that the coagulation/flocculation treatment using magnetic functionalized M. oleifera Lam coagulant was able to reduce the values of the physico-chemical parameters evaluated with reduced settling time.

  4. Initiator Systems Effect on Particle Coagulation and Particle Size Distribution in One-Step Emulsion Polymerization of Styrene

    Directory of Open Access Journals (Sweden)

    Baijun Liu

    2016-02-01

    Full Text Available Particle coagulation is a facile approach to produce large-scale polymer latex particles. This approach has been widely used in academic and industrial research owing to its higher polymerization rate and one-step polymerization process. Our work was motivated to control the extent (or time of particle coagulation. Depending on reaction parameters, particle coagulation is also able to produce narrowly dispersed latex particles. In this study, a series of experiments were performed to investigate the role of the initiator system in determining particle coagulation and particle size distribution. Under the optimal initiation conditions, such as cationic initiator systems or higher reaction temperature, the time of particle coagulation would be advanced to particle nucleation period, leading to the narrowly dispersed polymer latex particles. By using a combination of the Smoluchowski equation and the electrostatic stability theory, the relationship between the particle size distribution and particle coagulation was established: the earlier the particle coagulation, the narrower the particle size distribution, while the larger the extent of particle coagulation, the larger the average particle size. Combined with the results of previous studies, a systematic method controlling the particle size distribution in the presence of particle coagulation was developed.

  5. Moringa oleifera-mediated coagulation of textile wastewater and its biodegradation using novel consortium-BBA grown on agricultural waste substratum.

    Science.gov (United States)

    Bedekar, Priyanka A; Bhalkar, Bhumika N; Patil, Swapnil M; Govindwar, Sanjay P

    2016-10-01

    Generation of secondary sludge is a major concern of textile dye removal by coagulation process. Combinatorial coagulation-biodegradation treatment system has been found efficient in degradation of coagulated textile dye sludge. Moringa oleifera seed powder (700 mg L -1 ) was able to coagulate textile dyestuff from real textile wastewater with 98 % color removal. Novel consortium-BBA was found to decolorize coagulated dye sludge. Parameters that significantly affect coagulation process were optimized using response surface methodology. The bench-scale stirred tank reactor (50-L capacity) designed with optimized parameters for coagulation process could efficiently remove 98, 89, 78, and 67 % of American Dye Manufacturer's Institute (ADMI) in four repetitive cycles, respectively. Solid-state fermentation composting reactor designed to treat coagulated dye sludge showed 96 % removal of dye within 10 days. Coagulation of dyes from textile wastewater and degradation of coagulated dye sludge were confirmed by Fourier transform infrared spectroscopy (FTIR) analysis. Cell morphology assay, comet assay, and phytotoxicity confirmed the formation of less toxic products after coagulation and degradation mechanism.

  6. The effects of chemical coagulants on the decolorization of dyes by electrocoagulation using response surface methodology (RSM)

    Science.gov (United States)

    Butler, Erick B.; Hung, Yung-Tse; Mulamba, Oliver

    2017-09-01

    This study assessed the efficiency of electrocoagulation (ECF) coupled with an addition of chemical coagulant to decolorize textile dye. Tests were conducted using Box Behnken methodology to vary six parameters: dye type, weight, coagulant type, dose, initial pH and current density. The combination of electrocoagulation and chemical coagulation was able to decolorize dye up to 99.42 % in 30 min of treatment time which is remarkably shorter in comparison with using conventional chemical coagulation. High color removal was found to be contingent upon the dye type and current density, along with the interactions between the current density and the coagulant dose. The addition of chemical coagulants did enhanced treatment efficiency.

  7. Changes of plasma IL-6 and TNF-α levels during peri-operative period in patients undergoing laser photo-coagulation of greater saphenous varicosities

    International Nuclear Information System (INIS)

    Wang Taihan; Wang Chunxi

    2005-01-01

    Objective: To investigate the plasma levels of IL-6 and TNF-α during peri-operative period in patients undergoing laser photocoagulation of greater saphenous varicosities. Methods: Plasma IL-6 and TNF-α levels were determined with RIA before operation and 1, 3, 7, 14 days post-operatively in 110 patients with greater saphenous vein varicosity undergoing different forms of treatment (intravascular laser photo-coagulation 43, photo-coagulation combined with venous valve repair 35, high ligation and segmental stripping 32). Skin trophic disturbances were present in 56 of the 110 patients. Plasma IL-6 and TNF-α levels were also measured in 33 controls. Results: The plasma IL-6 and TNF-α levels in patients with skin trophic disturbances were significantly higher than those in controls (P<0.01), while levels in patients without skin lesions were not much changed. The plasma IL-6 and TNF-α levels were increased at first and dropped later to approaching pre-operative value by d14 in all the 110 patients after operation, however, the amount of increase was least and the normalization was also soonest in the simple photo-coagulation group, the reverse was true for the conventional operation group. Conclusion: Laser photo-coagulation is least stressful among the three types of operation and magnitude of changes of plasma IL-6 and TNF-α levels correctly reflects the intensity of stress. (authors)

  8. Normalization of coagulopathy is associated with improved outcome after isolated traumatic brain injury.

    Science.gov (United States)

    Epstein, Daniel S; Mitra, Biswadev; Cameron, Peter A; Fitzgerald, Mark; Rosenfeld, Jeffrey V

    2016-07-01

    Acute traumatic coagulopathy (ATC) has been reported in the setting of isolated traumatic brain injury (iTBI) and is associated with poor outcomes. We aimed to evaluate the effectiveness of procoagulant agents administered to patients with ATC and iTBI during resuscitation, hypothesizing that timely normalization of coagulopathy may be associated with a decrease in mortality. A retrospective review of the Alfred Hospital trauma registry, Australia, was conducted and patients with iTBI (head Abbreviated Injury Score [AIS] ⩾3 and all other body AIS normalized ratio ⩾1.3) were selected for analysis. Data on procoagulant agents used (fresh frozen plasma, platelets, cryoprecipitate, prothrombin complex concentrates, tranexamic acid, vitamin K) were extracted. Among patients who had achieved normalization of INR or survived beyond 24hours and were not taking oral anticoagulants, the association of normalization of INR and death at hospital discharge was analyzed using multivariable logistic regression analysis. There were 157 patients with ATC of whom 68 (43.3%) received procoagulant products within 24hours of presentation. The median time to delivery of first products was 182.5 (interquartile range [IQR] 115-375) minutes, and following administration of coagulants, time to normalization of INR was 605 (IQR 274-1146) minutes. Normalization of INR was independently associated with significantly lower mortality (adjusted odds ratio 0.10; 95% confidence interval 0.03-0.38). Normalization of INR was associated with improved mortality in patients with ATC in the setting of iTBI. As there was a substantial time lag between delivery of products and eventual normalization of coagulation, specific management of coagulopathy should be implemented as early as possible. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Ventricular metastasis resulting in disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Davis Ian D

    2005-05-01

    Full Text Available Abstract Background Disseminated Intravascular Coagulation (DIC complicates up to 7% of malignancies, the commonest solid organ association being adenocarcinoma. Transitional Cell Carcinoma (TCC has rarely been associated with DIC. Case presentation A 74-year-old woman with TCC bladder and DIC was found to have a cardiac lesion suspicious for metastatic disease. The DIC improved with infusion of plasma and administration of Vitamin K, however the cardiac lesion was deemed inoperable and chemotherapy inappropriate; given the patients functional status. We postulate that direct activation of the coagulation cascade by the intraventricular metastasis probably triggered the coagulopathy in this patient. Conclusion Cardiac metastases should be considered in cancer patients with otherwise unexplained DIC. This may influence treatment choices.

  10. Comparison of postoperative coagulation profiles and outcome for sugammadex versus pyridostigmine in 992 living donors after living-donor hepatectomy.

    Science.gov (United States)

    Moon, Young-Jin; Kim, Sung-Hoon; Kim, Jae-Won; Lee, Yoon-Kyung; Jun, In-Gu; Hwang, Gyu-Sam

    2018-03-01

    Donor safety is the major concern in living donor liver transplantation, although hepatic resection may be associated with postoperative coagulopathy. Recently, the use of sugammadex has been gradually increased, but sugammadex is known to prolong prothrombin time (PT) and activated partial thromboplastin time (aPTT). We compared the postoperative coagulation profiles and outcomes of sugammadex versus pyridostigmine group in donors receiving living donor hepatectomy.Consecutive donor hepatectomy performed between September 2013 and August 2016 was retrospectively analyzed. For reversal of rocuronium-induced neuromuscular blockade, donors received sugammadex 4 mg/kg or pyridostigmine 0.25 mg/kg. The primary end-points were laboratory findings (PT, aPTT, hemoglobin, platelet count) and clinically evaluated postoperative bleeding (relaparotomy for bleeding, cumulative volume collected in drains). Secondary outcomes were anesthesia time, postoperative hospital day.Of 992 donors, 383 treated with sugammadex and 609 treated with pyridostigmine for the reversal of neuromuscular blockade. There were no significant differences between both groups for drop in hemoglobin and platelet, prolongation in PT, aPTT, and the amount of 24-h drain volume. Bleeding events within 24 h were reported in 2 (0.3%) for pyridostigmine group and 0 (0%) for sugammadex group (P = .262). Anesthesia time was significantly longer in pyridostigmine group than that in sugammadex group (438.8 ± 71.4 vs. 421.3 ± 62.3, P sugammadex group (P = .002).Sugammadex 4 mg/kg was not associated with increased bleeding tendency, but associated with reduced anesthesia time and hospital stay. Therefore, sugammadex may be safely used and will decrease morbidity in donor undergoing living-donor hepatectomy.

  11. EFFECTIVENESS OF CHITOSAN AS NATURAL COAGULANT AID IN TREATING TURBID WATERS

    Directory of Open Access Journals (Sweden)

    B. Bina ، M. H. Mehdinejad ، M. Nikaeen ، H. Movahedian Attar

    2009-10-01

    Full Text Available During the last decade, there has been a concern about the relation between aluminum residuals in treated water and Alzheimer disease, and more interest has been considered on the development of natural coagulants such as chitosan. Chitosan, a natural linear biopolyaminosaccharide, is obtained by alkaline deacetylation of chitin. The present study was aimed to investigate the effects of alum as coagulant in conjunction with chitosan as coagulant aid on the removal of turbidity, hardness and Escherichia coli from water. A conventional jar test apparatus was employed for the tests. The optimum pH was observed between 7 to 7.5 for all turbidities. The optimum doses of alum and chitosan when used in conjunction, were 10mg/L and 1mg/L, 5mg/L and 0.5mg/L, and 5mg/L and 0.5mg/L in low, medium and high turbidities, respectively. Turbidity removal efficiency was resulted between %74.3 to %98.2 by alum in conjunction with chitosan. Residual Al+3 in treated water was less than 0.2 mg/L, meeting the international guidelines. The results showed that turbidity decrease provided also a primary Escherichia coli reduction of 2-4 log units within the first 1 to 2 hr of treatment. Hardness removal efficiency decreased when the total hardness increased from 102 to 476mg/L as CaCO3. At low initial turbidity, chitosan showed marginally better performance on hardness, especially at the ranges of 100 to 210 mg/L as CaCO3. In conclusion, coagulant aid showed a useful method for coagulation process. By using natural coagulants, considerable savings in chemicals and sludge handling cost may be achieved.

  12. Self-production of tissue factor-coagulation factor VII complex by ovarian cancer cells

    OpenAIRE

    Yokota, N; Koizume, S; Miyagi, E; Hirahara, F; Nakamura, Y; Kikuchi, K; Ruf, W; Sakuma, Y; Tsuchiya, E; Miyagi, Y

    2009-01-01

    Background: Thromboembolic events are a major complication in ovarian cancer patients. Tissue factor (TF) is frequently overexpressed in ovarian cancer tissue and correlates with intravascular thrombosis. TF binds to coagulation factor VII (fVII), changing it to its active form, fVIIa. This leads to activation of the extrinsic coagulation cascade. fVII is produced by the liver and believed to be supplied from blood plasma at the site of coagulation. However, we recently showed that ovarian ca...

  13. Identification of coagulation gene 3′UTR variants that are potentially regulated by microRNAs

    NARCIS (Netherlands)

    Vossen, Carla Y.; van Hylckama Vlieg, Astrid; Teruel-Montoya, Raúl; Salloum-Asfar, Salam; de Haan, Hugoline G.; Corral, Javier; Reitsma, Pieter H.; Koeleman, Bobby P.C.; Martínez, Constantino

    2017-01-01

    MicroRNAs have been recognized as critical regulators of gene expression and might affect the risk of venous thrombosis. We aimed to identify 3′ untranslated region (UTR) variants in coagulation genes that influence coagulation factor levels and venous thrombosis risk. The 3′UTR of coagulation genes

  14. The hydrophilic/hydrophobic ratio vs. dissolved organics removal by coagulation – A review

    Directory of Open Access Journals (Sweden)

    Djamel Ghernaout

    2014-07-01

    Full Text Available This review discusses the hydrophilic/hydrophobic ratio as a function of the hydrophilic and hydrophobic contents removal by coagulation process. It is well established that coagulation process could bring a reduction in dissolved organic carbon of around 30–60% by increasing the coagulant dose and optimising reaction pH, in which large organic molecules with hydrophobic property was removed preferentially. Furthermore, the literature affirmed that the greater removal of UV-absorbing substances indicates that alum coagulation preferentially removed the hydrophobic fraction of the total organic carbon. For the hydrophobic fraction, it needs to be removed entirely without its transformation into hydrophilic fractions by coagulation process avoiding pre-chlorination/pre-oxidation due to the risk of organic molecules fragmentation. Determining the exact numerical values of the hydrophilic/hydrophobic ratio for raw water and treated water at different stages of the treatment processes in a water treatment plant, as for the DCO/DBO5 ratio in the case of wastewater treatment, would help on more focusing on OM control and removal.

  15. Study on Coagulant Dosing Control System of Micro Vortex Water Treatment

    Science.gov (United States)

    Fengping, Hu; Qi, Fan; Wenjie, Hu; Xizhen, He; Hongling, Dai

    2018-03-01

    In view of the characteristics of nonlinearity, large time delay and multi disturbance in the process of coagulant dosing in water treatment, it is difficult to control the dosage of coagulant. According to the four indexes of raw water quality parameters (raw water flow, turbidity, pH value) and turbidity of sedimentation tank, the micro vortex coagulation dosing control model is constructed based on BP neural network and GA. The forecast results of BP neural network model are ideal, and after the optimization of GA, the prediction accuracy of the model is partly improved. The prediction error of the optimized network is ±0.5 mg/L, and has a better performance than non-optimized network.

  16. Coagulation and electrocoagulation for co-treatment of stabilized landfill leachate and municipal wastewater

    Directory of Open Access Journals (Sweden)

    Mohini Verma

    2018-04-01

    Full Text Available Landfill leachate and municipal wastewater at various ratios (1:20, 1:10, 1:7 and 1:5 were subjected to coagulation and electrocoagulation (EC. Alum was used in conventional coagulation at pH 6 and aluminum plate as electrode was used in EC at a current density of 386 A/m2 with 5 cm inter electrode spacing. Treatment efficiency was assessed from removal of chemical oxygen demand (COD, total suspended solids (TSS, turbidity, ammonia, nitrate and phosphate. At 1:5 ratio of landfill leachate to municipal wastewater, highest COD removal was with 3.8 g/L alum whereas highest turbidity removal was with 3.3 g/L alum during coagulation. EC exhibited almost similar removal efficiency for all the parameters at different ratios tested except for COD which was considerably higher at 1:20 ratio. Aluminum consumption from electrode was 0.7 g/L following EC as compared to 3.8 g/L alum used in coagulation. The amount of sludge produced was found to be higher with EC as compared to coagulation which could be due to the fact that the electrochemical method was performed for a longer duration than conventional coagulation. For minimal sludge generation, EC reaction time should be ∼30 min. Further studies with EC process on costing and sludge generation will help to advance the technology for wastewater treatment.

  17. Treatment of sugar beet extraction juice stillage by natural coagulants extracted from common bean

    OpenAIRE

    Prodanović Jelena M.; Šćiban Marina B.; Antov Mirjana G.; Kukić Dragana V.; Vasić Vesna M.

    2015-01-01

    Distillery wastewaters have a great pollution potential, and pollution caused by them is one of the most critical environmental issues. This study is concerned with the coagulation efficiency of a new, environmental friendly, natural coagulant extracted from common bean seeds in the primary treatment of distillery wastewater in the bioethanol production from sugar beet juice. Active coagulation components were extracted from ground seeds of common bean with...

  18. Numerical Simulation of the Coagulation Dynamics of Blood

    Directory of Open Access Journals (Sweden)

    T. Bodnár

    2008-01-01

    Full Text Available The process of platelet activation and blood coagulation is quite complex and not yet completely understood. Recently, a phenomenological meaningful model of blood coagulation and clot formation in flowing blood that extends existing models to integrate biochemical, physiological and rheological factors, has been developed. The aim of this paper is to present results from a computational study of a simplified version of this coupled fluid-biochemistry model. A generalized Newtonian model with shear-thinning viscosity has been adopted to describe the flow of blood. To simulate the biochemical changes and transport of various enzymes, proteins and platelets involved in the coagulation process, a set of coupled advection–diffusion–reaction equations is used. Three-dimensional numerical simulations are carried out for the whole model in a straight vessel with circular cross-section, using a finite volume semi-discretization in space, on structured grids, and a multistage scheme for time integration. Clot formation and growth are investigated in the vicinity of an injured region of the vessel wall. These are preliminary results aimed at showing the validation of the model and of the numerical code.

  19. Coagulation competence and fluid recruitment after moderate blood loss in young men

    DEFF Research Database (Denmark)

    Zaar, Morten; Mørkeberg, Jakob; Pott, Frank C

    2014-01-01

    The coagulation system is activated by a reduction of the central blood volume during orthostatic stress and lower body negative pressure suggesting that also a blood loss enhances coagulation. During bleeding, however, the central blood volume is supported by fluid recruitment to the circulation...

  20. Brownian coagulation at high particle concentrations

    NARCIS (Netherlands)

    Trzeciak, T.M.

    2012-01-01

    The process of Brownian coagulation, whereby particles are brought together by thermal motion and grow by collisions, is one of the most fundamental processes influencing the final properties of particulate matter in a variety of technically important systems. It is of importance in colloids,

  1. Quantifying interspecific coagulation efficiency of phytoplankton

    DEFF Research Database (Denmark)

    Hansen, J.L.S.; Kiørboe, Thomas

    1997-01-01

    . nordenskjoeldii. Mutual coagulation between Skeletonema costatum and the non-sticky cel:ls of Ditylum brightwellii also proceeded with hall the efficiency of S. costatum alone. The latex beads were suitable to be used as 'standard particles' to quantify the ability of phytoplankton to prime aggregation...

  2. The Inflammatory Actions of Coagulant and Fibrinolytic Proteases in Disease

    Directory of Open Access Journals (Sweden)

    Michael Schuliga

    2015-01-01

    Full Text Available Aside from their role in hemostasis, coagulant and fibrinolytic proteases are important mediators of inflammation in diseases such as asthma, atherosclerosis, rheumatoid arthritis, and cancer. The blood circulating zymogens of these proteases enter damaged tissue as a consequence of vascular leak or rupture to become activated and contribute to extravascular coagulation or fibrinolysis. The coagulants, factor Xa (FXa, factor VIIa (FVIIa, tissue factor, and thrombin, also evoke cell-mediated actions on structural cells (e.g., fibroblasts and smooth muscle cells or inflammatory cells (e.g., macrophages via the proteolytic activation of protease-activated receptors (PARs. Plasmin, the principle enzymatic mediator of fibrinolysis, also forms toll-like receptor-4 (TLR-4 activating fibrin degradation products (FDPs and can release latent-matrix bound growth factors such as transforming growth factor-β (TGF-β. Furthermore, the proteases that convert plasminogen into plasmin (e.g., urokinase plasminogen activator evoke plasmin-independent proinflammatory actions involving coreceptor activation. Selectively targeting the receptor-mediated actions of hemostatic proteases is a strategy that may be used to treat inflammatory disease without the bleeding complications of conventional anticoagulant therapies. The mechanisms by which proteases of the coagulant and fibrinolytic systems contribute to extravascular inflammation in disease will be considered in this review.

  3. A parametric comparative study of electrocoagulation and coagulation using ultrafine quartz suspensions.

    Science.gov (United States)

    Kiliç, Mehtap Gülsün; Hoşten, Cetin; Demirci, Sahinde

    2009-11-15

    This paper attempts to compare electrocoagulation using aluminum anodes and stainless steel cathodes with conventional coagulation by aluminum sulfate dosing on aqueous suspensions of ultrafine quartz. Several key parameters affecting the efficiency of electrocoagulation and coagulation were investigated with laboratory scale experiments in search of optimal parameter values. Optimal values of the parameters were determined on the basis of the efficiency of turbidity removal from ultrafine quartz suspensions. The parameters investigated in the study were suspension pH, electrical potential, current density, electrocoagulation time, and aluminum dosage. A comparison between electrocoagulation and coagulation was made on the basis of total dissolved aluminum, revealing that electrocoagulation and coagulation were equally effective at the same aluminum dosage for the removal of quartz particles from suspensions. Coagulation, however, was more effective in a wider pH range (pH 6-9) than electrocoagulation which yielded optimum effectiveness in a relatively narrower pH range around 9, where, in both methods, these pH values corresponded to near-zero zeta potentials of quartz particles. Furthermore, experimental results confirmed that electrocoagulation could display some pH buffering capacity. The kinetics of electrocoagulation was very fast (<10 min) in approaching a residual turbidity, which could be modeled with a second-order rate equation.

  4. Improvement of NOM Removal from Water Resources by Modifying the Coagulation Process

    Directory of Open Access Journals (Sweden)

    F Vaezi, A Mohagheghian, J Nouri, MR Eshraghian, A Ghasri

    2005-01-01

    Full Text Available As a result of the regulations on DBPs, interest in NOM removal is increasing and many water treatment plants in developed countries have started to measure the concentration of TOC in their finished waters. Promulgation of the rules will substantially increase these efforts in other countries too. Since the cost of TOC (and DBPs determination was high, it was decided to study the traditional analysis of COD as a surrogate measure to detect the organic constituents in raw water and the extent to which optimized coagulation with ferric chloride can increase COD removal. The two water samples studied belonged to Karaj and Jajrood Rivers. For both samples the observed values of COD removal by coagulation at lower pH (about 1-1.5 pH values less than the regular pH were about 85-95 percent without making water turbidity unacceptable. In order to determine the effects of organic content on coagulation, synthetic samples were also prepared with much higher COD values. Again, considerable increases in COD removal have been observed for most of these samples only by decreasing 0.5-2 pH value. The results indicated that a modified coagulation process without need to much increasing the amount of coagulant can be developed for these water samples.

  5. Comparison of electrocoagulation and chemical coagulation for heavy metal removal

    Energy Technology Data Exchange (ETDEWEB)

    Akbal, F.; Camci, S. [Ondokuz Mayis University, Engineering Faculty, Environmental Engineering Department, Kurupelit, Samsun (Turkey)

    2010-10-15

    Copper (Cu), chromium (Cr), and nickel (Ni) removal from metal plating wastewater by electrocoagulation and chemical coagulation was investigated. Chemical coagulation was performed using either aluminum sulfate or ferric chloride, whereas electrocoagulation was done in an electrolytic cell using aluminum or iron electrodes. By chemical coagulation, Cu-, Cr-, and Ni-removal of 99.9 % was achieved with aluminum sulfate and ferric chloride dosages of 500, 1000, and 2000 mg L{sup -1}, respectively. Removal of metals by electrocoagulation was affected by the electrode material, wastewater pH, current density, number of electrodes, and electrocoagulation time. Electrocoagulation with iron electrodes at a current density of 10 mA cm{sup -2}, electrocoagulation time of 20 min, and pH 3.0 resulted in 99.9 % Cu-, 99.9 % Cr-, and 98 % Ni-removal. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  6. HemaExplorer: a database of mRNA expression profiles in normal and malignant haematopoiesis

    DEFF Research Database (Denmark)

    Bagger, Frederik Otzen; Rapin, Nicolas; Theilgaard-Mönch, Kim

    2013-01-01

    lead to full integrity of the data in the database. The HemaExplorer has comprehensive visualization interface that can make it useful as a daily tool for biologists and cancer researchers to assess the expression patterns of genes encountered in research or literature. HemaExplorer is relevant for all......The HemaExplorer (http://servers.binf.ku.dk/hemaexplorer) is a curated database of processed mRNA Gene expression profiles (GEPs) that provides an easy display of gene expression in haematopoietic cells. HemaExplorer contains GEPs derived from mouse/human haematopoietic stem and progenitor cells...... as well as from more differentiated cell types. Moreover, data from distinct subtypes of human acute myeloid leukemia is included in the database allowing researchers to directly compare gene expression of leukemic cells with those of their closest normal counterpart. Normalization and batch correction...

  7. Monitoring of tissue optical properties during thermal coagulation of ex vivo tissues.

    Science.gov (United States)

    Nagarajan, Vivek Krishna; Yu, Bing

    2016-09-01

    Real-time monitoring of tissue status during thermal ablation of tumors is critical to ensure complete destruction of tumor mass, while avoiding tissue charring and excessive damage to normal tissues. Currently, magnetic resonance thermometry (MRT), along with magnetic resonance imaging (MRI), is the most commonly used technique for monitoring and assessing thermal ablation process in soft tissues. MRT/MRI is very expensive, bulky, and often subject to motion artifacts. On the other hand, light propagation within tissue is sensitive to changes in tissue microstructure and physiology which could be used to directly quantify the extent of tissue damage. Furthermore, optical monitoring can be a portable, and cost-effective alternative for monitoring a thermal ablation process. The main objective of this study, is to establish a correlation between changes in tissue optical properties and the status of tissue coagulation/damage during heating of ex vivo tissues. A portable diffuse reflectance spectroscopy system and a side-firing fiber-optic probe were developed to study the absorption (μa (λ)), and reduced scattering coefficients (μ's (λ)) of native and coagulated ex vivo porcine, and chicken breast tissues. In the first experiment, both porcine and chicken breast tissues were heated at discrete temperature points between 24 and 140°C for 2 minutes. Diffuse reflectance spectra (430-630 nm) of native and coagulated tissues were recorded prior to, and post heating. In a second experiment, porcine tissue samples were heated at 70°C and diffuse reflectance spectra were recorded continuously during heating. The μa (λ) and μ's (λ) of the tissues were extracted from the measured diffuse reflectance spectra using an inverse Monte-Carlo model of diffuse reflectance. Tissue heating was stopped when the wavelength-averaged scattering plateaued. The wavelength-averaged optical properties, and , for native porcine tissues (n = 66) at room temperature, were 5.4

  8. Coagulation-flocculation process applied to wastewaters generated in hydrocarbon-contaminated soil washing: Interactions among coagulant and flocculant concentrations and pH value.

    Science.gov (United States)

    Torres, Luis G; Belloc, Claudia; Vaca, Mabel; Iturbe, Rosario; Bandala, Erick R

    2009-11-01

    Wastewater produced in the contaminated soil washing was treated by means of coagulation-flocculation (CF) process. The wastewater contained petroleum hydrocarbons, a surfactant, i.e., sodium dodecyl sulfate (SDS) as well as salts, brownish organic matter and other constituents that were lixiviated from the soil during the washing process. The main goal of this work was to develop a process for treating the wastewaters generated when washing hydrocarbon-contaminated soils in such a way that it could be recycled to the washing process, and also be disposed at the end of the process properly. A second objective was to study the relationship among the coagulant and flocculant doses and the pH at which the CF process is developed, for systems where methylene blue active substances (MBAS) as well as oil and greases were present. The results for the selection of the right coagulant and flocculant type and dose, the optimum pH value for the CF process and the interactions among the three parameters are detailed along this work. The best coagulant and flocculant were FeCl(3) and Tecnifloc 998 at doses of 4,000 and 1 mg/L, correspondingly at pH of 5. These conditions gave color, turbidity, chemical oxygen demand (COD) and conductivity removals of 99.8, 99.6, 97.1 and 35%, respectively. It was concluded that it is feasible to treat the wastewaters generated in the contaminated soil washing process through CF process, and therefore, wastewaters could be recycled to the washing process or disposed to drainage.

  9. REMOVAL OF PHENOL AND SURFACTANT FROM LANDFILL LEACHATE BY COAGULATION-FLOCCULATION PROCESS

    Directory of Open Access Journals (Sweden)

    H. BAKRAOUY

    2016-02-01

    Full Text Available Following the action of rainfall and natural fermentation, the stored waste produces a liquid fraction called leachate. This leachate is rich in organic matter (biodegradable but also refractory and trace elements. There are many techniques of treating the leachate, in particular, biological, physicochemical, membrane processes. The choice of a technique instead of another depends on several parameters including: the age of the leachate, composition... In this work we applied a coagulation-flocculation process to treat intermediate landfill leachate of Rabat city with a combined ferric chloride coagulant and a polymer flocculant. We were inspired by full factorial design, including twenty five experiments, to determine optimal dosages of coagulant and flocculant. We operate at pH 8.4, the best removal efficiencies obtained were 88 % for Turbidity, 98 % for Phenol and 82 % for surfactant. The optimum dosages values determined by this study were 13.2 g∙L-1 of coagulant, 62 mL∙L-1 of flocculant.

  10. Demonstration of the Coagulation and Diffusion of Homemade Slime Prepared under Acidic Conditions without Borate

    Science.gov (United States)

    Isokawa, Naho; Fueda, Kazuki; Miyagawa, Korin; Kanno, Kenichi

    2015-01-01

    Poly(vinyl alcohol) (PVA) precipitates in many kinds of aqueous salt solutions. While sodium sulfate, a coagulant for PVA fiber, precipitates PVA to yield a white rigid gel, coagulation of PVA with aluminum sulfate, a coagulant for water treatment, yields a slime-like viscoelastic fluid. One type of homemade slime is prepared under basic…

  11. Removal of congo red and methylene blue from waste water using coagulation

    International Nuclear Information System (INIS)

    Ghaffar, S.; Nosheen, S.; Ahmad, N.

    2011-01-01

    The textile industry has been condemned as being one of the world's worst offenders in terms of pollution Because of increasing population and industrial developments, a huge amount of wastewater is discharged to the environment above the level that the nature can eliminate. Many techniques like oxidation, reduction, physical treatment and biological method are available for removal of colored dyes from wastewater. The work presented here involved the decolorisation of wastewater containing congo red and methylene blue using various coagulants such as alum, bentonite and lime. The effect of various experimental factors such as dosage of coagulants, contact time between coagulant and dye and concentration of dyes and working environment like shaking and static was studied. Under static condition alum give almost 43% removal of congo red while with 10 minutes shaking 74 % removal of 80 dye was achieved with same coagulant. The highest removal of congo red was found to be 99.5 % by using alum after 30 minutes of shaking but in case of methylene blue it intensified the color and gave negative results. Lime gave only 33 % color removal of congo red under static conditions while 57% color was removed under shaking conditions. Maximum color removal achieved by lime was 89% at 40 minutes with shaking condition. Lime gave 60% removal of methylene blue in static condition and 90% removal in shaking condition and maximum absorbance at 80 ppm was 90%. Bentonite also used for the removal of methylene blue and gave 89% removal in shaking condition. By increasing shaking time %age removal increased to 100% at 40 min. And amount of coagulant increased the removal efficiency it attained 100% in both lime and bentonite coagulant for methylene blue Overall alum was found to be better coagulant for the removal of congo red from its aqueous solution. Lime and bentonite both proved better and economical for removal of methylene blue from aqueous solution at lab scale. (author)

  12. Comprehensive reuse of drinking water treatment residuals in coagulation and adsorption processes.

    Science.gov (United States)

    Jung, Kyung-Won; Hwang, Min-Jin; Park, Dae-Seon; Ahn, Kyu-Hong

    2016-10-01

    While drinking water treatment residuals (DWTRs) inevitably lead to serious problems due to their huge amount of generation and limitation of landfill sites, their unique properties of containing Al or Fe contents make it possible to reuse them as a beneficial material for coagulant recovery and adsorbent. Hence, in the present study, to comprehensively handle and recycle DWTRs, coagulant recovery from DWTRs and reuse of coagulant recovered residuals (CRs) were investigated. In the first step, coagulant recovery from DWTRs was conducted using response surface methodology (RSM) for statistical optimization of independent variables (pH, solid content, and reaction time) on response variable (Al recovery). As a result, a highly acceptable Al recovery of 97.5 ± 0.4% was recorded, which corresponds to 99.5% of the predicted Al recovery. Comparison study of recovered and commercial coagulant from textile wastewater treatment indicated that recovered coagulant has reasonable potential for use in wastewater treatment, in which the performance efficiencies were 68.5 ± 2.1% COD, 97.2 ± 1.9% turbidity, and 64.3 ± 1.0% color removals at 50 mg Al/L. Subsequently, in a similar manner, RSM was also applied to optimize coagulation conditions (Al dosage, initial pH, and reaction time) for the maximization of real cotton textile wastewater treatment in terms of COD, turbidity, and color removal. Overall performance revealed that the initial pH had a remarkable effect on the removal performance compared to the effects of other independent variables. This is mainly due to the transformation of metal species form with increasing or decreasing pH conditions. Finally, a feasibility test of CRs as adsorbent for phosphate adsorption from aqueous solution was conducted. Adsorption equilibrium of phosphate at different temperatures (10-30 °C) and initial levels of pH (3-11) indicated that the main mechanisms of phosphate adsorption onto CRs are endothermic and chemical

  13. 21 CFR 864.5400 - Coagulation instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...

  14. Is the T1ρ MRI profile of hyaline cartilage in the normal hip uniform?

    Science.gov (United States)

    Rakhra, Kawan S; Cárdenas-Blanco, Arturo; Melkus, Gerd; Schweitzer, Mark E; Cameron, Ian G; Beaulé, Paul E

    2015-04-01

    T1ρ MRI is an imaging technique sensitive to proteoglycan (PG) content of hyaline cartilage. However, normative T1ρ values have not been established for the weightbearing cartilage of the hip, and it is not known whether it is uniform or whether there is topographic variation. Knowledge of the T1ρ profile of hyaline cartilage in the normal hip is important for establishing a baseline against which comparisons can be made to experimental and clinical arthritic subjects. In this diagnostic study, we determined (1) the T1ρ MRI values of hyaline cartilage of the normal hip; and (2) whether the T1ρ MRI profile of the normal hip hyaline cartilage is uniform. Fourteen asymptomatic volunteers (11 men, three women; mean age, 35 years) prospectively underwent 1.5-T T1ρ MRI of a single hip. The weightbearing hyaline cartilage bilayer of the acetabulum and femoral head was evaluated on sagittal images and segmented into four zones: (1) anterior; (2) anterosuperior; (3) posterosuperior; and (4) and posterior. For the full region of interest and within each zone and each sagittal slice, we calculated the mean T1ρ relaxation value, a parameter that indirectly quantifies PG content, where T1ρ is inversely related to PG concentration. There was variation in the T1ρ relaxation values depending on zone (anterior to posterior) and slice (medial to lateral). When combining the most anterior quadrants (Zones 1 and 2), the T1ρ relaxation values were lower than those in the combined posterior quadrants (Zones 3 and 4) (30.4 msec versus 32.2 msec, respectively; p = 0.002), reflecting higher PG concentration. There was a difference between the T1ρ relaxation values of the sagittal slices (p = 0.038), most pronounced anteriorly in Zone 1 (26.6 msec, p = 0.001). With a selective combination of zones and slices, there were lower mean T1ρ values in the anterolateral-most region compared with the remainder of the weightbearing portion of the hip (28.6 msec versus 32.2 msec

  15. In silico modeling and experimental evidence of coagulant protein interaction with precursors for nanoparticle functionalization.

    Science.gov (United States)

    Okoli, Chuka; Sengottaiyan, Selvaraj; Arul Murugan, N; Pavankumar, Asalapuram R; Agren, Hans; Kuttuva Rajarao, Gunaratna

    2013-10-01

    The design of novel protein-nanoparticle hybrid systems has applications in many fields of science ranging from biomedicine, catalysis, water treatment, etc. The main barrier in devising such tool is lack of adequate information or poor understanding of protein-ligand chemistry. Here, we establish a new strategy based on computational modeling for protein and precursor linkers that can decorate the nanoparticles. Moringa oleifera (MO2.1) seed protein that has coagulation and antimicrobial properties was used. Superparamagnetic nanoparticles (SPION) with precursor ligands were used for the protein-ligand interaction studies. The molecular docking studies reveal that there are two binding sites, one is located at the core binding site; tetraethoxysilane (TEOS) or 3-aminopropyl trimethoxysilane (APTES) binds to this site while the other one is located at the side chain residues where trisodium citrate (TSC) or Si60 binds to this site. The protein-ligand distance profile analysis explains the differences in functional activity of the decorated SPION. Experimentally, TSC-coated nanoparticles showed higher coagulation activity as compared to TEOS- and APTES-coated SPION. To our knowledge, this is the first report on in vitro experimental data, which endorses the computational modeling studies as a powerful tool to design novel precursors for functionalization of nanomaterials; and develop interface hybrid systems for various applications.

  16. Optical coherence tomography-guided laser microsurgery for blood coagulation with continuous-wave laser diode.

    Science.gov (United States)

    Chang, Feng-Yu; Tsai, Meng-Tsan; Wang, Zu-Yi; Chi, Chun-Kai; Lee, Cheng-Kuang; Yang, Chih-Hsun; Chan, Ming-Che; Lee, Ya-Ju

    2015-11-16

    Blood coagulation is the clotting and subsequent dissolution of the clot following repair to the damaged tissue. However, inducing blood coagulation is difficult for some patients with homeostasis dysfunction or during surgery. In this study, we proposed a method to develop an integrated system that combines optical coherence tomography (OCT) and laser microsurgery for blood coagulation. Also, an algorithm for positioning of the treatment location from OCT images was developed. With OCT scanning, 2D/3D OCT images and angiography of tissue can be obtained simultaneously, enabling to noninvasively reconstruct the morphological and microvascular structures for real-time monitoring of changes in biological tissues during laser microsurgery. Instead of high-cost pulsed lasers, continuous-wave laser diodes (CW-LDs) with the central wavelengths of 450 nm and 532 nm are used for blood coagulation, corresponding to higher absorption coefficients of oxyhemoglobin and deoxyhemoglobin. Experimental results showed that the location of laser exposure can be accurately controlled with the proposed approach of imaging-based feedback positioning. Moreover, blood coagulation can be efficiently induced by CW-LDs and the coagulation process can be monitored in real-time with OCT. This technology enables to potentially provide accurate positioning for laser microsurgery and control the laser exposure to avoid extra damage by real-time OCT imaging.

  17. Influence of micellar calcium and phosphorus on rennet coagulation properties of cows milk.

    Science.gov (United States)

    Malacarne, Massimo; Franceschi, Piero; Formaggioni, Paolo; Sandri, Sandro; Mariani, Primo; Summer, Andrea

    2014-05-01

    The main requirement for milk processed in most cheese typologies is its rennet coagulation ability. Despite the increasing number of studies, the causes for abnormal coagulation of milk are not fully understood. The aim of this study was to ascertain relationships between milk characteristics and its rennet coagulation ability, focusing on the influence of calcium (Ca) and phosphorus (P). Ca and P are essential constituents of the micelles. Micellar P can be present as part of colloidal calcium phosphate (inorganic-P) or covalently bound to caseins as phosphate groups (casein-P). Eighty one herd milk samples (SCCproperties. Optimal milk was characterised by the highest contents of major constituents, protein fractions and minerals, lowest content of chloride and highest values of titratable acidity. Non-coagulating milk was characterised by the highest values of pH and the lowest of titratable acidity. At micellar level, Optimal milk showed the highest values of colloidal Ca, casein-P and colloidal Mg (g/100 g casein), while Non-coagulating milk showed the lowest values. Interestingly, there was no statistical difference regarding the content of colloidal inorganic-P (g/100 g casein) between Optimal and Non-coagulating milks. Overall, high mineralisation of the micelle (expressed as g inorganic-P/100 g casein) positively affect its rennetability. However, excessive mineralisation could lead to a reduction of the phosphate groups (g casein-P/100 g casein) available for curd formation.

  18. Development of Coagulation Factor Probes for the Identification of Procoagulant Circulating Tumor Cells

    Energy Technology Data Exchange (ETDEWEB)

    Tormoen, Garth W.; Cianchetti, Flor A. [Department of Biomedical Engineering, Oregon Health and Science University, Portland, OR (United States); Bock, Paul E. [Department of Pathology, Microbiology and Immunology, Vanderbilt University School of Medicine, Nashville, TN (United States); McCarty, Owen J. T., E-mail: tormoeng@ohsu.edu [Department of Biomedical Engineering, Oregon Health and Science University, Portland, OR (United States); Department of Cell and Developmental Biology, Oregon Health and Science University, Portland, OR (United States); Division of Hematology and Medical Oncology, Department of Medicine, Oregon Health and Science University, Portland, OR (United States)

    2012-09-06

    Metastatic cancer is associated with a hypercoagulable state, and pathological venous thromboembolic disease is a significant source of morbidity and the second leading cause of death in patients with cancer. Here we aimed to develop a novel labeling strategy to detect and quantify procoagulant circulating tumor cells (CTCs) from patients with metastatic cancer. We hypothesize that the enumeration of procoagulant CTCs may be prognostic for the development of venous thrombosis in patients with cancer. Our approach is based on the observation that cancer cells are capable of initiating and facilitating cell-mediated coagulation in vitro, whereby activated coagulation factor complexes assemble upon cancer cell membrane surfaces. Binding of fluorescently labeled, active site-inhibited coagulation factors VIIa, Xa, and IIa to the metastatic breast cancer cell line, MDA-MB-231, non-metastatic colorectal cell line, SW480, or metastatic colorectal cell line, SW620, was characterized in a purified system, in anticoagulated blood and plasma, and in plasma under conditions of coagulation. We conclude that a CTC labeling strategy that utilizes coagulation factor-based fluorescent probes may provide a functional assessment of the procoagulant potential of CTCs, and that this strategy is amenable to current CTC detection platforms.

  19. Isolation and characterization of coagulant extracted from Moringa oleifera seed by salt solution.

    Science.gov (United States)

    Okuda, T; Baes, A U; Nishijima, W; Okada, M

    2001-02-01

    It is known that M. oleifera contains a natural coagulant in the seeds. In our previous research, the method using salt water to extract the active coagulation component from M. oleifera seeds was developed and compared with the conventional method using water. In this research, the active coagulation component was purified from a NaCl solution crude extract of Moringa oleifera seeds. The active component was isolated and purified from the crude extract through a sequence of steps that included salting-out by dialysis, removal of lipids and carbohydrates by homogenization with acetone, and anion exchange. Specific coagulation activity of the active material increased up to 34 times more than the crude extract after the ion exchange. The active component was not the same as that of water extract. The molecular weight was about 3000 Da. The Lowry method and the phenol-sulfuric acid method indicated that the active component was neither protein nor polysaccharide. The optimum pH of the purified active component for coagulation of turbidity was pH 8 and above. Different from the conventional water extracts, the active component can be used for waters with low turbidity without increase in the dissolved organic carbon concentration.

  20. Real-time electrical impedimetric monitoring of blood coagulation process under temperature and hematocrit variations conducted in a microfluidic chip.

    Directory of Open Access Journals (Sweden)

    Kin Fong Lei

    Full Text Available Blood coagulation is an extremely complicated and dynamic physiological process. Monitoring of blood coagulation is essential to predict the risk of hemorrhage and thrombosis during cardiac surgical procedures. In this study, a high throughput microfluidic chip has been developed for the investigation of the blood coagulation process under temperature and hematocrit variations. Electrical impedance of the whole blood was continuously recorded by on-chip electrodes in contact with the blood sample during coagulation. Analysis of the impedance change of the blood was conducted to investigate the characteristics of blood coagulation process and the starting time of blood coagulation was defined. The study of blood coagulation time under temperature and hematocrit variations was shown a good agreement with results in the previous clinical reports. The electrical impedance measurement for the definition of blood coagulation process provides a fast and easy measurement technique. The microfluidic chip was shown to be a sensitive and promising device for monitoring blood coagulation process even in a variety of conditions. It is found valuable for the development of point-of-care coagulation testing devices that utilizes whole blood sample in microliter quantity.

  1. Exploration by radioactive fibrinogen of intrarenal coagulation phenomena. Preliminary results

    International Nuclear Information System (INIS)

    Simon, Jacques.

    1974-01-01

    The participation of fibrin deposits in kidney pathology was studied by the use of a radioactive tracer involved in the coagulation phenomenon: iodine 131-labelled fibrinogen. The isotopic exploration consists of a fibrinogen kinetics study combined with external counting over the kidney regions. The different stages of the procedure are described: separation, purification and labelling of fibrinogen; characteristics of the radioactive fibrinogen used; practical details of the examination itself; data analysis method. A chapter devoted to verifications and discussions of the procedure is followed by a report on the exploration of intrarenal coagulation phenomena in 30 kidney disease patients. In conclusion, the study of fibrinogen kinetics is considered as the most suitable method to detect local or slight intravascular coagulation phenomena. The sensitivity of the isotopic exploration is very satisfactory. The main criticism directed against this method is that the exploration is general and therefore blind [fr

  2. Comparison of electrocoagulation and chemical coagulation ...

    African Journals Online (AJOL)

    In this work, electrocoagulation and chemical coagulation were applied to the exit effluent of a textile factory located at Douala (Cameroon).The investigations were focused on the operational (pH, conductivity) and pollution parameters (COD, total phosphorus, turbidity). The electrolytic treatment was carried out with 0.4 A ...

  3. Enhancement of sedimentation and coagulation with static magnetic field

    Science.gov (United States)

    Zieliński, Marcin; Dębowski, Marcin; Hajduk, Anna; Rusanowska, Paulina

    2017-11-01

    The static magnetic field can be an alternative method for wastewater treatment. It has been proved that this physical factor, accelerates the biochemical processes, catalyzes advanced oxidation, intensifies anaerobic and aerobic processes or reduces swelling of activated sludge. There are also reports proving the positive impact of the static magnetic field on the coagulation and sedimentation, as well as the conditioning and dewatering of sludge. In order to be applied in larger scale the published results should be verified and confirmed. In the studies, the enhancement of sedimentation by the static magnetic field was observed. The best sedimentation was noted in the experiment, where magnetizers were placed on activated sludge bioreactor and secondary settling tank. No effect of the static magnetic field on coagulation with the utilization of PIX 113 was observed. However, the static magnetic field enhanced coagulation with the utilization of PAX-XL9. The results suggest that increased sedimentation of colloids and activated sludge, can in practice mean a reduction in the size of the necessary equipment for sedimentation with an unchanged efficiency of the process.

  4. Composite wastewater treatment by aerated electrocoagulation and modified peroxi-coagulation processes.

    Science.gov (United States)

    Kumar, Abhijeet; Nidheesh, P V; Suresh Kumar, M

    2018-08-01

    Treatment of composite wastewater generating from the industrial estates is a great challenge. The present study examines the applicability of aerated electrocoagulation and modified peroxi-coagulation processes for removing color and COD from composite wastewater. Iron plates were used as anodes and cathodes in both electrochemical processes and experiments were carried out in a working volume of 2 L. Aeration enhanced the efficiency of electrocoagulation process significantly. More than 50% of COD and 60% of color were removed after 1 h of electrocoagulation process operated at pH 3 and applied voltage of 1 V. Efficiency of the modified peroxi-coagulation process was significantly higher than that of aerated electrocoagulation. COD and color removal efficiencies of the modified peroxi-coagulation process were found as 77.7% and 97%, respectively after 1 h of electrolysis operated at 1 V, solution pH 3 and 50 mM hydrogen peroxide addition. This improved efficiency of modified peroxi-coagulation compared to aerated electrocoagulation is mainly due to the attack of in-situ generated hydroxyl radicals. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Monte Carlo simulation of aggregate morphology for simultaneous coagulation and sintering

    International Nuclear Information System (INIS)

    Schmid, Hans-Joachim; Tejwani, Saurabh; Artelt, Christian; Peukert, Wolfgang

    2004-01-01

    A model for simulation of the three-dimensional morphology of nano-structured aggregates formed by concurrent coagulation and sintering is presented. Diffusion controlled cluster-cluster aggregation is assumed to be the prevailing coagulation mechanism which is implemented using a Monte-Carlo algorithm. Sintering is modeled as a successive overlapping of spherical primary particles, which are allowed to grow as to preserve overall mass. Simulations are characterized by individual ratios τ of characteristic collision to fusion time. A number of resulting aggregate-structures is displayed and reveals structure formation by coagulation and sintering for different values of τ. These aggregates are described qualitatively and quantitatively by their mass fractal dimension D f and radius of gyration. The fractal dimension increases from 1.86 for pure aggregation to ∼ 2.75 for equal characteristic time scales. As sintering turns out to be more and more relevant, increasingly compact aggregates start to form and the radius of gyration decreases significantly. The simulation results clearly reveal a strong dependence of the fractal dimension on the kinetics of the concurrent coagulation and sintering processes. Considering appropriate values of D f in aerosol process simulations may therefore be important in many cases

  6. Disseminated intravascular coagulation caused by moojenactivase, a procoagulant snake venom metalloprotease.

    Science.gov (United States)

    Sartim, Marco A; Cezarette, Gabriel N; Jacob-Ferreira, Anna L; Frantz, Fabiani G; Faccioli, Lucia H; Sampaio, Suely V

    2017-10-01

    Snake venom toxins that activate coagulation factors are key players in the process of venom-induced coagulopathy, and account for severe clinical manifestations. The present study applies a variety of biochemical, hematological, and histopathological approaches to broadly investigate the intravascular and systemic effects of moojenactivase (MooA), the first described PIIId subclass metalloprotease isolated from Bothrops sp. venom that activates coagulation factors. MooA induced consumption coagulopathy with high toxic potency, characterized by prolongation of prothrombin and activated partial thromboplastin time, consumption of fibrinogen and the plasma coagulation factors X and II, and thrombocytopenia. MooA promoted leukocytosis and expression of the proinflammatory cytokines interleukin-6 and tumor necrosis factor-α, accompanied by tissue factor-dependent procoagulant activity in peripheral blood mononuclear cells. This metalloprotease also caused intravascular hemolysis, elevated plasma levels of creatine kinase-MB, aspartate transaminase, and urea/creatinine, and induced morphopathological alterations in erythrocytes, heart, kidney, and lungs associated with thrombosis and hemorrhage. Diagnosis of MooA-induced disseminated intravascular coagulation represents an important approach to better understand the pathophysiology of Bothrops envenomation and develop novel therapeutic strategies targeting hemostatic disturbances. Copyright © 2017. Published by Elsevier B.V.

  7. Enhanced Coagulation Efficiency of Moringa Oleifera Seeds Through Selective Oil Extraction

    Directory of Open Access Journals (Sweden)

    Suleyman A. Muyibi

    2012-10-01

    Full Text Available In this laboratory based study, varying quantities of oil, corresponding to 20 % w/w, 25 % w/w and 30 % w/w kernel weight extracted from Moringa oleifera seeds ( S1, S2, S3 respectively  were applied in the coagulation of model turbid water (kaolin suspension and turbid river water samples from River Batang Kali and River Selangor in Malaysia to determine the percentage oil removed which gave the best coagulation efficiency. For model turbid water (kaolin suspension coagulation of low turbidity of 35 NTU, medium turbidity of 100 NTU and high turbidity of 300 NTU, sample S2  gave the best turbidity removal corresponding to 91.7%, 95.5% and 99% respectively. Application of sample S2 to River Batang Kali with low initial turbidity of 32 NTU and high initial turbidity of 502 NTU gave a highest turbidity removal of 69% and 99% respectively. Application to River Selangor with medium initial turbidity- of 87 NTU and high initial turbidity of 466 NTU gave a highest residual turbidity' of 94% and 98.9%,  respectively.Key words: Moringa oleifera seed, selective oil extraction, coagulation, model turbid water (kaolin suspension, river water, turbidity removal.

  8. Simple and rapid methods for purification and characterization of active coagulants from the seeds of Vigna unguiculata and Parkinsonia aculeata.

    Science.gov (United States)

    Marobhe, N J; Dalhammar, G; Gunaratna, K R

    2007-06-01

    The coagulating properties of aqueous crude extracts and purified proteins of Vigna unguiculata and Parkinsonia aculeata seeds, which are traditional water coagulants in rural areas of Tanzania, were studied. The coagulation activity assays were done using one millilitre (ml) of kaolin water samples. Coagulating proteins were purified in two-step ion exchange chromatography. The properties of coagulant protein were compared with Moringa oleifera. Coagulating components eluted by 0.6 M NaCl in both coagulants are cationic proteins that have the molecular mass of about 6 kDa, which is very similar to that of M. oleifera. The proteins of V. unguiculata and P. aculeata eluted by 0.3 M NaCl also harbour coagulation activity but proteins eluted with 0.6 M NaCl have higher activity. The dosage for coagulation using purified proteins of both coagulants is about 5 to 10 times lower than that of crude seed extracts. The optimum floc settling time of water treated by crude seed extracts and purified proteins ranged between two and two and half hours. Coagulating proteins of both coagulants eluted by 0.6 M NaCl are thermoresistant and retained coagulation activity of 87% to 92% after boiling for two hours at 80 degrees C and one hour at 95 degrees C. Thermotolerant proteins of V. unguiculata eluted by 0.6 M NaCl and P. aculeata have wider pH range of 5.5 to 8.5 for coagulation activity than those of M. oleifera proteins. The present investigation reveals the possibility of using purified natural coagulants for water treatment to produce safe drinking water.

  9. Moojenactivase, a novel pro-coagulant PIIId metalloprotease isolated from Bothrops moojeni snake venom, activates coagulation factors II and X and induces tissue factor up-regulation in leukocytes.

    Science.gov (United States)

    Sartim, Marco A; Costa, Tassia R; Laure, Helen J; Espíndola, Milena S; Frantz, Fabiani G; Sorgi, Carlos A; Cintra, Adélia C O; Arantes, Eliane C; Faccioli, Lucia H; Rosa, José C; Sampaio, Suely V

    2016-05-01

    Coagulopathies following snakebite are triggered by pro-coagulant venom toxins, in which metalloproteases play a major role in envenomation-induced coagulation disorders by acting on coagulation cascade, platelet function and fibrinolysis. Considering this relevance, here we describe the isolation and biochemical characterization of moojenactivase (MooA), a metalloprotease from Bothrops moojeni snake venom, and investigate its involvement in hemostasis in vitro. MooA is a glycoprotein of 85,746.22 Da, member of the PIIId group of snake venom metalloproteases, composed of three linked disulfide-bonded chains: an N-glycosylated heavy chain, and two light chains. The venom protease induced human plasma clotting in vitro by activating on both blood coagulation factors II (prothrombin) and X, which in turn generated α-thrombin and factor Xa, respectively. Additionally, MooA induced expression of tissue factor (TF) on the membrane surface of peripheral blood mononuclear cells (PBMC), which led these cells to adopt pro-coagulant characteristics. MooA was also shown to be involved with production of the inflammatory mediators TNF-α, IL-8 and MCP-1, suggesting an association between MooA pro-inflammatory stimulation of PBMC and TF up-regulation. We also observed aggregation of washed platelets when in presence of MooA; however, the protease had no effect on fibrinolysis. Our findings show that MooA is a novel hemostatically active metalloprotease, which may lead to the development of coagulopathies during B. moojeni envenomation. Moreover, the metalloprotease may contribute to the development of new diagnostic tools and pharmacological approaches applied to hemostatic disorders.

  10. Natural coagulation inhibitors and active protein c resistance in preeclampsia

    Directory of Open Access Journals (Sweden)

    Cengiz Demir

    2010-01-01

    Full Text Available INTRODUCTION: The etiology of preeclampsia is not fully established. A few studies have shown a relationship between natural coagulation inhibitors and preeclampsia. OBJECTIVES: The purpose of this study was to investigate the status of natural coagulation inhibitors and active protein C resistance (APC-R in preeclampsia. PATIENTS AND METHODS: We studied 70 women with preeclampsia recruited consecutively and 70 healthy pregnant and 70 nonpregnant women as controls. Plasma protein C (PC, free protein S (fPS, antithrombin III (ATIII and APC-R were evaluated. RESULTS: ATIII values were found to be significantly lower in preeclamptic patients than in the control groups (p< 0.001. Nevertheless, there was no significant difference between the healthy pregnant and nonpregnant women groups (p=0.141. The fPS values of the preeclamptic and healthy pregnant groups were lower than that of the nonpregnant group (p< 0.001, and the fPS value of the preeclamptic pregnant women was lower than that of healthy pregnant women (p<0.001. The PC value of the preeclamptic pregnant women was lower than that of the control groups (p< 0.001. The PC value of the healthy pregnant women was lower than that of the nonpregnant women (p< 0.001. The mean APC activity values were lower in the preeclamptic patients than that of the control groups (p< 0.001, p< 0.001. The APC-R positivity rates of the preeclamptic groups were higher than that of the control groups (p<0.001. CONCLUSIONS: This study demonstrated that ATIII, fPS, PC values and APC resistance were lower and APC-R positivity was higher in preeclamptic women than in normal pregnant and nonpregnant women.

  11. EFFECTS OF ORAL CONTRACEPTIVES ON COAGULATING FACTORS

    Directory of Open Access Journals (Sweden)

    H.R. Sadeghipour Roudsari.

    1997-06-01

    Full Text Available Thirty young, healthy, nonsmoking women (mean age approximately 28 years taking low-dose oral contraceptive pills were recruited for the study of the effects of these pills on coagulating factors. Twenty subjects were taking LD pill (Ethinyl estradiol 0.03 mg, levonorgestrel 0.15 mg and 10 others were taking Cilest (Ethinyl estradiol 0.035 mg, Norgestimate 0.25 mg for six months. The control subjects did not receive any oral contraceptives or other medications. Our results showed that:"n1. There is no significant difference between the effects of LD and Cilest (with a different progestin content on coagulating factors."n2. No significant changes were observed between both LD users and controls in PT, APTT, and fibrinogen levels."n3. No significant changes were observed between both Cilest users and controls in PT, APTT, and fibrinogen levels."n

  12. Enrichment of trace metals in water utilizing the coagulation of soybean protein

    International Nuclear Information System (INIS)

    Musha, Soichiro; Takahashi, Yoshihisa.

    1975-01-01

    An enrichment of trace metals in water with a coagulated soybean protein and the complex-forming character of heavy metal ions with the soybean protein were investigated by means of emission spectrography. Fixed amounts of soybean milk (collector) and delta-gluconic lactone (coagulant) were added to a sample solution containing various metal ions, and then the mixture was heated to boiling in order to coagulate the protein. The coagulum (soybean curd) separated from the suspension with a centrifuge was burned to ashes with a low temperature plasma asher. Then metals enriched in the soybean curd were determined by means of emission spectrography. The pH of the solution was adjusted to 4.4--5.0 by adding suitable amounts of delta-gluconic lactone for the complete coagulation of the soybean protein. The proposed method can be applied to the collection and enrichment of various metal ions such as gold, silver, mercury, platinum, cadmium, beryllium, palladium, antimony, gallium, indium, cerium, lanthanum, thorium, yttrium, zirconium, etc. Those metals are not detectable in the original soybean. (auth.)

  13. Characterization of Natural Organic Matter by FeCl3 Coagulation

    Science.gov (United States)

    Cahyonugroho, O. H.; Hidayah, E. N.

    2018-01-01

    Natural organic matter (NOM) is heterogenous mixture of organic compounds that enter the water from various decomposition and metabolic reactions, including animal, plant, domestic and industrial wastes. NOM refers to group of carbon-based compounds that are found in surface water and ground water. The aim of the study is to assess organic matter characteristics in Jagir River as drinking water source and to characterize the organic components that could be removed during coagulation. Coagulation is the common water treatment process can be used to remove NOM with FeCl3 coagulant in various dosage. NOM surrogates, including total organic carbon (TOC), ultraviolet absorbance at 254 nm (UV254) and specific UV absorbance (SUVA) were chosen to assess the organic removal. Results of jar test experiments showed that NOM can be removed about 40% of NOM surrogates with 200 mg/L FeCl3. About 60% removal of total organic fraction, which is mainly humic substances, as detected by size exclusion chromatography (SEC).

  14. Changes in Chara hispida L. morphology in response to phosphate aluminium coagulant application

    Directory of Open Access Journals (Sweden)

    Rybak Michał

    2018-03-01

    Full Text Available Progressing eutrophication of waterbodies requires measures to be undertaken that aim at halting or reversing negative changes in the environment. Chemical restoration is one of the most common methods used for lake treatment, where iron or aluminium phosphate coagulants are applied. However, their chemical qualities pose the risk of acidification and aluminium ion release, which become toxic in acidic conditions. The influence of coagulants on aquatic plants, including charophytes that are very valuable from the ecological perspective, is little recognised. For this reason, the aim of the research was to define changes in the growth pattern of the charophyte Chara hispida under the influence of an aluminium coagulant. The research was carried out in mesocosms (0.8 m3 located in situ in a lake. Polyaluminium chloride was applied once to each chamber in doses of 50.0, 100.0 and 200.0 ml m−3. Coagulant concentrations reflected aggressive restoration aimed at precipitation of phosphates, suspension and water colour at the same time. It was proved that the coagulant had inhibited the growth and slightly reduced the length of branchlets, and simultaneously elongated internode cells. Changes in the total length as well as the length of branchlets were caused by a strong pH decrease of the environment which simultaneously induced higher aluminium solubility and toxicity. Elongation of internode cells was caused by reduced light availability, resulting from high water turbidity in the first stage of coagulant’s application, and then from the charophytes’ thallus being covered by a coagulated suspension precipitated from water.

  15. Coagulation Factor Tests: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Coagulation Factor Assay; 156–7 p. ...

  16. Plasma concentrations of blood coagulation factor VII measured by immunochemical and amidolytic methods

    DEFF Research Database (Denmark)

    Bladbjerg, E-M; Gram, J; Jespersen, J

    2000-01-01

    Ever since the coagulant activity of blood coagulation factor VII (FVII:C) was identified as a risk indicator of cardiac death, a large number of studies have measured FVII protein concentrations in plasma. FVII protein concentrations are either measured immunologically with an ELISA method (FVII...

  17. Coagulation and flocculation in the preparation of drinking water in a pilot plant

    Directory of Open Access Journals (Sweden)

    Iličić Gordana

    2005-01-01

    Full Text Available The objective of the practical part in this article was to explore the influence of different parameters on coagulation and flocculation processes as well as the influence of this stage on other stages in water purification. Analysis of the water samples was conducted in the chemical laboratory of Banja Luka Municipal Waterworks using standard methods for analyzing drinking water. The results are presented as diagrams that show the dependence of different parameters as a function of the residual turbidity and the content of natural organic matters in water. The following conclusions were drawn It is necessary to conduct the chemical treatment of raw water with the aim to satisfy chemical and bacteriological standards for drinking water. The best results were achieved with Al2(SO4s as coagulant,. Counterrecoil sludge in an amount of 2-3% in relation with the total quantity of water has a positive impacts on coagulation-flocculation processes. 4. For effective purification, all the conditions for coagulation-flocculation must be adjusted for the filter to have a longer useful life. One of example is correction of the pH to pH=7, coagulant dose 20 mg/L Al2(SO4s, flocculant dose 0.1 mg/L PE, counterrecoil sludge dose 90 L/h PM.

  18. Transparent exopolymer particles (TEP) removal efficiency by a combination of coagulation and ultrafiltration to minimize SWRO membrane fouling

    KAUST Repository

    Li, Sheng; Lee, Shang-Tse; Sinha, Shahnawaz; Leiknes, TorOve; Amy, Gary L.; Ghaffour, NorEddine

    2016-01-01

    This study investigated the impact of coagulation on the transformation between colloidal and particulate transparent exopolymer particles (TEP) in seawater; and the effectiveness of a combined pretreatment consisting of coagulation and UF on minimizing TEP fouling of seawater reverse osmosis (SWRO) membranes. Coagulation with ferric chloride at pH 5 substantially transformed colloidal TEP (0.1–0.4) into particulate TEP (>0.4) leading to a better membrane fouling control. Both 50 and 100 kDa molecular weight cut-off (MWCO) UF membranes removed most of particulate and colloidal TEP without the assistance of coagulation, but coagulation is still necessary for better UF fouling control. The improvement of combined SWRO pretreatment with coagulation and 50 kDa UF membranes was not that much significant compared to UF pretreatment with 50 KDa alone. Therefore, the minimal coagulant dosage for seawater containing TEP should be based on the UF fouling control requirements rather than removal efficiency. © 2016 Elsevier Ltd

  19. Transparent exopolymer particles (TEP) removal efficiency by a combination of coagulation and ultrafiltration to minimize SWRO membrane fouling

    KAUST Repository

    Li, Sheng

    2016-07-02

    This study investigated the impact of coagulation on the transformation between colloidal and particulate transparent exopolymer particles (TEP) in seawater; and the effectiveness of a combined pretreatment consisting of coagulation and UF on minimizing TEP fouling of seawater reverse osmosis (SWRO) membranes. Coagulation with ferric chloride at pH 5 substantially transformed colloidal TEP (0.1–0.4) into particulate TEP (>0.4) leading to a better membrane fouling control. Both 50 and 100 kDa molecular weight cut-off (MWCO) UF membranes removed most of particulate and colloidal TEP without the assistance of coagulation, but coagulation is still necessary for better UF fouling control. The improvement of combined SWRO pretreatment with coagulation and 50 kDa UF membranes was not that much significant compared to UF pretreatment with 50 KDa alone. Therefore, the minimal coagulant dosage for seawater containing TEP should be based on the UF fouling control requirements rather than removal efficiency. © 2016 Elsevier Ltd

  20. Early-stage evolution of particle size distribution with Johnson's SB function due to Brownian coagulation

    International Nuclear Information System (INIS)

    Tang Hong; Lin Jianzhong

    2013-01-01

    The moment method can be used to determine the time evolution of particle size distribution due to Brownian coagulation based on the general dynamic equation (GDE). But the function form of the initial particle size distribution must be determined beforehand for the moment method. If the assumed function type of the initial particle size distribution has an obvious deviation from the true particle population, the evolution of particle size distribution may be different from the real evolution tendency. Thus, a simple and general method is proposed based on the moment method. In this method, the Johnson's S B function is chosen as a general distribution function to fit the initial distributions including the log normal (L-N), Rosin–Rammler (R-R), normal (N-N) and gamma distribution functions, respectively. Meanwhile, using the modified beta function to fit the L-N, R-R, N-N and gamma functions is also conducted as a comparison in order to present the advantage of the Johnson's S B function as the general distribution function. And then, the time evolution of particle size distributions using the Johnson's S B function as the initial distribution can be obtained by several lower order moment equations of the Johnson's S B function in conjunction with the GDE during the Brownian coagulation process. Simulation experiments indicate that fairly reasonable results of the time evolution of particle size distribution can be obtained with this proposed method in the free molecule regime, transition regime and continuum plus near continuum regime, respectively, at the early time stage of evolution. The Johnson's S B function has the ability of describing the early time evolution of different initial particle size distributions. (paper)

  1. Change of particle size distribution during Brownian coagulation

    International Nuclear Information System (INIS)

    Lee, K.W.

    1984-01-01

    Change in particle size distribution due to Brownian coagulation in the continuum regime has been stuied analytically. A simple analytic solution for the size distribution of an initially lognormal distribution is obtained based on the assumption that the size distribution during the coagulation process attains or can, at least, be represented by a time dependent lognormal function. The results are found to be in a form that corrects Smoluchowski's solution for both polydispersity and size-dependent kernel. It is further shown that regardless of whether the initial distribution is narrow or broad, the spread of the distribution is characterized by approaching a fixed value of the geometric standard deviation. This result has been compared with the self-preserving distribution obtained by similarity theory. (Author)

  2. The effects of nanomaterials on blood coagulation in hemostasis and thrombosis.

    Science.gov (United States)

    Simak, Jan; De Paoli, Silvia

    2017-09-01

    The blood coagulation balance in the organism is achieved by the interaction of the blood platelets (PLTs) with the plasma coagulation system (PCS) and the vascular endothelial cells. In healthy organism, these systems prevent thrombosis and, in events of vascular damage, enable blood clotting to stop bleeding. The dysregulation of hemostasis may cause serious thrombotic and/or hemorrhagic pathologies. Numerous engineered nanomaterials are being investigated for biomedical purposes and are unavoidably exposed to the blood. Also, nanomaterials may access vascular system after occupational, environmental, or other types of exposure. Thus, it is essential to evaluate the effects of engineered nanomaterials on hemostasis. This review focuses on investigations of nanomaterial interactions with the blood components involved in blood coagulation: the PCS and PLTs. Particular emphases include the pathophysiology of effects of nanomaterials on the PCS, including the kallikrein-kinin system, and on PLTs. Methods for investigating these interactions are briefly described, and a review of the most important studies on the interactions of nanomaterials with plasma coagulation and platelets is provided. WIREs Nanomed Nanobiotechnol 2017, 9:e1448. doi: 10.1002/wnan.1448 For further resources related to this article, please visit the WIREs website. © Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  3. Commonly Used Dietary Supplements on Coagulation Function during Surgery

    Directory of Open Access Journals (Sweden)

    Chong-Zhi Wang

    2015-07-01

    Full Text Available Background: Patients who undergo surgery appear to use dietary supplements significantly more frequently than the general population. Because they contain pharmacologically active compounds, dietary supplements may affect coagulation and platelet function during the perioperative period through direct effects, pharmacodynamic interactions, and pharmacokinetic interactions. However, in this regard, limited studies have been conducted that address the pharmacological interactions of dietary supplements. To avoid possible bleeding risks during surgery, information about the potential complications of dietary supplements during perioperative management is important for physicians. Methods: Through a systematic database search of all available years, articles were identified in this review if they included dietary supplements and coagulation/platelet function, while special attention was paid to studies published after 1990. Results: Safety concerns are reported in commercially available dietary supplements. Effects of the most commonly used natural products on blood coagulation and platelet function are systematically reviewed, including 11 herbal medicines (echinacea, ephedra, garlic, ginger, ginkgo, ginseng, green tea, kava, saw palmetto, St John’s wort, and valerian and four other dietary supplements (coenzyme Q10, glucosamine and chondroitin sulfate, fish oil, and vitamins. Bleeding risks of garlic, ginkgo, ginseng, green tea, saw palmetto, St John’s wort, and fish oil are reported. Cardiovascular instability was observed with ephedra, ginseng, and kava. Pharmacodynamic and pharmacokinetic interactions between dietary supplements and drugs used in the perioperative period are discussed. Conclusions: To prevent potential problems associated with the use of dietary supplements, physicians should be familiar with the perioperative effects of commonly used dietary supplements. Since the effects of dietary supplements on coagulation and platelet

  4. Commonly Used Dietary Supplements on Coagulation Function during Surgery

    Science.gov (United States)

    Wang, Chong-Zhi; Moss, Jonathan; Yuan, Chun-Su

    2015-01-01

    Abstract Background Patients who undergo surgery appear to use dietary supplements significantly more frequently than the general population. Because they contain pharmacologically active compounds, dietary supplements may affect coagulation and platelet function during the perioperative period through direct effects, pharmacodynamic interactions, and pharmacokinetic interactions. However, in this regard, limited studies have been conducted that address the pharmacological interactions of dietary supplements. To avoid possible bleeding risks during surgery, information about the potential complications of dietary supplements during perioperative management is important for physicians. Methods Through a systematic database search of all available years, articles were identified in this review if they included dietary supplements and coagulation/platelet function, while special attention was paid to studies published after 1990. Results Safety concerns are reported in commercially available dietary supplements. Effects of the most commonly used natural products on blood coagulation and platelet function are systematically reviewed, including 11 herbal medicines (echinacea, ephedra, garlic, ginger, ginkgo, ginseng, green tea, kava, saw palmetto, St John’s wort, and valerian) and four other dietary supplements (coenzyme Q10, glucosamine and chondroitin sulfate, fish oil, and vitamins). Bleeding risks of garlic, ginkgo, ginseng, green tea, saw palmetto, St John’s wort, and fish oil are reported. Cardiovascular instability was observed with ephedra, ginseng, and kava. Pharmacodynamic and pharmacokinetic interactions between dietary supplements and drugs used in the perioperative period are discussed. Conclusions To prevent potential problems associated with the use of dietary supplements, physicians should be familiar with the perioperative effects of commonly used dietary supplements. Since the effects of dietary supplements on coagulation and platelet function are

  5. Commonly Used Dietary Supplements on Coagulation Function during Surgery.

    Science.gov (United States)

    Wang, Chong-Zhi; Moss, Jonathan; Yuan, Chun-Su

    2015-09-01

    Patients who undergo surgery appear to use dietary supplements significantly more frequently than the general population. Because they contain pharmacologically active compounds, dietary supplements may affect coagulation and platelet function during the perioperative period through direct effects, pharmacodynamic interactions, and pharmacokinetic interactions. However, in this regard, limited studies have been conducted that address the pharmacological interactions of dietary supplements. To avoid possible bleeding risks during surgery, information of potential complications of dietary supplements during perioperative management is important for physicians. Through a systematic database search of all available years, articles were identified in this review if they included dietary supplements and coagulation/platelet function, while special attention was paid to studies published after 1990. Safety concerns are reported in commercially available dietary supplements. Effects of the most commonly used natural products on blood coagulation and platelet function are systematically reviewed, including 11 herbal medicines (echinacea, ephedra, garlic, ginger, ginkgo, ginseng, green tea, kava, saw palmetto, St John's wort, and valerian) and 4 other dietary supplements (coenzyme Q 10 , glucosamine and chondroitin sulfate, fish oil, and vitamins). Bleeding risks of garlic, ginkgo, ginseng, green tea, saw palmetto, St John's wort, and fish oil are reported. Cardiovascular instability was observed with ephedra, ginseng, and kava. Pharmacodynamic and pharmacokinetic interactions between dietary supplements and drugs used in the perioperative period are discussed. To prevent potential problems associated with the use of dietary supplements, physicians should be familiar with the perioperative effects of commonly used dietary supplements. Since the effects of dietary supplements on coagulation and platelet function are difficult to predict, it is prudent to advise their

  6. Effects of coagulating enzyme types (commercial calf rennet ...

    African Journals Online (AJOL)

    Effects of coagulating enzyme types (commercial calf rennet, Aspergillus niger var. awamori as recombinant chymosin and rhizomucor miehei as microbial rennet) on the chemical and sensory characteristics of white pickled cheese.

  7. Extensive small-angle X-ray scattering studies of blood coagulation factor VIIa reveal interdomain flexibility

    DEFF Research Database (Denmark)

    Mosbæk, Charlotte Rode; Nolan, David; Persson, Egon

    2010-01-01

    Blood coagulation factor VIIa (FVIIa) is used in the treatment of replacement therapy resistant hemophilia patients, and FVIIa is normally activated upon complex formation with tissue factor (TF), potentially in context with structural rearrangements. The solution behavior of uncomplexed FVIIa...... is important for understanding the mechanism of activation and for the stability and activity of the pharmaceutical product. However, crystal structures of FVIIa in complex with TF and of truncated free FVIIa reveal different overall conformations while previous small-angle scattering studies suggest FVIIa...... causing resistance to activation, thereby emphasizing the connection between the distribution of different conformations of FVII and the mechanism of activation....

  8. The impact of pre-oxidation with potassium permanganate on cyanobacterial organic matter removal by coagulation.

    Science.gov (United States)

    Naceradska, Jana; Pivokonsky, Martin; Pivokonska, Lenka; Baresova, Magdalena; Henderson, Rita K; Zamyadi, Arash; Janda, Vaclav

    2017-05-01

    The study investigates the effect of permanganate pre-oxidation on the coagulation of peptides/proteins of Microcystis aeruginosa which comprise a major proportion of the organic matter during cyanobacterial bloom decay. Four different permanganate dosages (0.1, 0.2, 0.4 and 0.6 mg KMnO 4 mg -1 DOC) were applied prior to coagulation by ferric sulphate. Moreover, changes in sample characteristics, such as UV 254 , DOC content and molecular weight distribution, after pre-oxidation were monitored. The results showed that permanganate pre-oxidation led to a reduction in coagulant dose, increased organic matter removals by coagulation (by 5-12% depending on permanganate dose), microcystin removal (with reductions of 91-96%) and a shift of the optimum pH range from 4.3 to 6 without to 5.5-7.3 with pre-oxidation. Degradation of organic matter into inorganic carbon and adsorption of organic matter onto hydrous MnO 2 are suggested as the main processes responsible for coagulation improvement. Moreover, permanganate prevented the formation of Fe-peptide/protein complexes that inhibit coagulation at pH about 6.2 without pre-oxidation. The study showed that carefully optimized dosing of permanganate improves cyanobacterial peptide/protein removal, with the benefit of microcystin elimination. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. A preliminary study of opuntia stricta as a coagulant for turbidity removal in surface waters

    International Nuclear Information System (INIS)

    Mukhtar, A.

    2015-01-01

    Natural polymers, extracted from plants, can be used as coagulants for water treatment in addition to metal salts and synthetic polymers. Natural materials may offer benefits such as local production, lesser health hazards and affordability for developing world. Opuntia stricta plant, a cactus specie native to Mexico, has been explored in this study for its efficacy as coagulant. Efficiency of Opuntia stricta was assessed on the basis of turbidity removal from lab prepared and surface water samples. The effect of water pH on its performance was also analyzed. The study results revealed that removal efficiency of Opuntia stricta for turbidity removal remains consistent within a wide pH range (pH 5 to 10), in contrast to other coagulants which are pH dependent. Furthermore, pH of the water remains constant during coagulation and pH adjustment may not be required for subsequent treatment processes, which is often needed in case metal coagulants are used. Residual turbidity below 20 NTU is conveniently achieved by using Opuntia stricta even when it is used at very low doses. Formation of exceptionally large flocs and their linear configuration reveals the possibility that mechanism of coagulation by Opuntia stricta is adsorption and inter-particle bridging. (author)

  10. On the variability of the salting-out curves of proteins of normal human plasma and serum

    NARCIS (Netherlands)

    Steyn-Parvé, Elizabeth P.; Hout, A.J. van den

    1953-01-01

    Salting-out curves of proteins of normal human plasma reflect the influence of a number of other factors besides the protein composition: the manner of obtaining the blood, the nature of the anti-coagulant used, the non-protein components of the plasma. Diagrams of serum and plasma obtained from

  11. The mechanism and properties of acid-coagulated milk gels

    Directory of Open Access Journals (Sweden)

    Chanokphat Phadungath

    2005-03-01

    Full Text Available Acid-coagulated milk products such as fresh acid-coagulated cheese varieties and yogurt areimportant dairy food products. However, little is known regarding the mechanisms involved in gel formation, physical properties of acid gels, and the effects of processing variables such as heat treatment and gelation temperature on the important physical properties of acid milk gels. This paper reviews the modern concepts of possible mechanisms involved in the formation of particle milk gel aggregation, along with recent developments including the use of techniques such as dynamic low amplitude oscillatory rheology to observe the gel formation process, and confocal laser scanning microscopy to monitor gel microstructure.

  12. EVALUATION OF PERIODONTAL TISSUES CONDITION IN CHILDREN WITH BLOOD COAGULABILITY PATHOLOGY

    Directory of Open Access Journals (Sweden)

    M. A. Gavrilenko

    2013-12-01

    Full Text Available Background. Actuality of the problem is determined by the high prevalence of inflammatory diseases of periodontal tissues in children with blood pathology (100%. Primary prevention of dental caries and periodontal diseases has the exceptional importance in the dentist’s work with children who have blood coagulability disorders. Prevention of dental diseases of the oral cavity in this category of patients has a number of features because there is the risk of bleeding during both home oral hygiene and professional hygiene. Exogenous prevention (fluoride-containing gels, varnishes, solutions, sealants also has its own peculiarities in these children. On the other hand, the impossibility of preventive measures implementation is the significant factor in the pathogenesis of gingivitis and subsequently periodontitis in children with disorders of blood coagulability. Aim. To examine the status of oral hygiene in children with blood coagulability disorders. To examine the severity of inflammatory and destructive changes in the periodontal tissues in children with disorders of blood coagulability. To investigate timing and frequency of oral hygiene implementation in children with disorders of blood coagulability. To reveal the interrelations between the intensity, prevalence of periodontal tissues disorders in children with blood coagulability pathology and the periods of tooth development, taking into account the influence of risk factors and frequency of oral hygiene. Materials and methods. 120 children between 2 and 18 years old with blood coagulability disorders (hemophilia A, B, thrombocytopenia, thrombocytopathy were examined. Children were divided into following age groups: I – 2-5 years old (40 children, II – 6-10 years old (40 children, III – 11-18 years old (40 children, according to the periods of tooth development, with an equal number of children in groups according to diagnoses. Hygiene index value was determined according to

  13. Evaluation of periodontal tissues condition in children with blood coagulability pathology

    Directory of Open Access Journals (Sweden)

    M. A. Gavrilenko

    2013-12-01

    Full Text Available Background. Actuality of the problem is determined by the high prevalence of inflammatory diseases of periodontal tissues in children with blood pathology (100%. Primary prevention of dental caries and periodontal diseases has the exceptional importance in the dentist’s work with children who have blood coagulability disorders. Prevention of dental diseases of the oral cavity in this category of patients has a number of features because there is the risk of bleeding during both home oral hygiene and professional hygiene. Exogenous prevention (fluoride-containing gels, varnishes, solutions, sealants also has its own peculiarities in these children. On the other hand, the impossibility of preventive measures implementation is the significant factor in the pathogenesis of gingivitis and subsequently periodontitis in children with disorders of blood coagulability. Aim.To examine the status of oral hygiene in children with blood coagulability disorders.To examine the severity of inflammatory and destructive changes in the periodontal tissues in children with disorders of blood coagulability. To investigate timing and frequency of oral hygiene implementation in children with disorders of blood coagulability. To reveal the interrelations between the intensity, prevalence of periodontal tissues disorders in children with blood coagulability pathology and the periods of tooth development, taking into account the influence of risk factors and frequency of oral hygiene. Materials and methods. 120 children between 2 and 18 years old with blood coagulability disorders (hemophilia A, B, thrombocytopenia, thrombocytopathy were examined. Children were divided into following age groups: I – 2-5 years old (40 children, II – 6-10 years old (40 children, III – 11-18 years old (40 children, according to the periods of tooth development, with an equal number of children in groups according to diagnoses. Hygiene index value was determined according to Fedorov

  14. Influence of ionizing radiation and 12-crown-4 on coagulation system components of rat blood

    International Nuclear Information System (INIS)

    Kratenko, R.Yi.

    2006-01-01

    The influence of 12-crown-4 and ionizing radiation on some components of blood coagulation system: Ca 2+ contents and prostaglandin concentrations in the blood serum, and erythrocyte contents in the blood plasma are studied. The influence of 12-crown-4 and ionizing radiation increases the coagulational properties of erythrocytes. The synergism of ionizing irradiation and 12-crown-4 influence blood coagulation process points out at the occurrence of radiomimetic properties of the latter

  15. Rapid removal of fine particles from mine water using sequential processes of coagulation and flocculation.

    Science.gov (United States)

    Jang, Min; Lee, Hyun-Ju; Shim, Yonsik

    2010-04-01

    The processes of coagulation and flocculation using high molecular weight long-chain polymers were applied to treat mine water having fine flocs of which about 93% of the total mass was less than 3.02 microm, representing the size distribution of fine particles. Six different combinations of acryl-type anionic flocculants and polyamine-type cationic coagulants were selected to conduct kinetic tests on turbidity removal in mine water. Optimization studies on the types and concentrations of the coagulant and flocculant showed that the highest rate of turbidity removal was obtained with 10 mg L(-1) FL-2949 (coagulant) and 12 mg L(-1) A333E (flocculant), which was about 14.4 and 866.7 times higher than that obtained with A333E alone and that obtained through natural precipitation by gravity, respectively. With this optimized condition, the turbidity of mine water was reduced to 0 NTU within 20 min. Zeta potential measurements were conducted to elucidate the removal mechanism of the fine particles, and they revealed that there was a strong linear relationship between the removal rate of each pair of coagulant and flocculant application and the zeta potential differences that were obtained by subtracting the zeta potential of flocculant-treated mine water from the zeta potential of coagulant-treated mine water. Accordingly, through an optimization process, coagulation-flocculation by use of polymers could be advantageous to mine water treatment, because the process rapidly removes fine particles in mine water and only requires a small-scale plant for set-up purposes owing to the short retention time in the process.

  16. Pretreatment of palm oil mill effluent (POME) using Moringa oleifera seeds as natural coagulant.

    Science.gov (United States)

    Bhatia, Subhash; Othman, Zalina; Ahmad, Abdul Latif

    2007-06-25

    Moringa oleifera seeds, an environmental friendly and natural coagulant are reported for the pretreatment of palm oil mill effluent (POME). In coagulation-flocculation process, the M. oleifera seeds after oil extraction (MOAE) are an effective coagulant with the removal of 95% suspended solids and 52.2% reduction in the chemical oxygen demand (COD). The combination of MOAE with flocculant (NALCO 7751), the suspended solids removal increased to 99.3% and COD reduction was 52.5%. The coagulation-flocculation process at the temperature of 30 degrees C resulted in better suspended solids removal and COD reduction compared to the temperature of 40, 55 and 70 degrees C. The MOAE combined with flocculant (NALCO 7751) reduced the sludge volume index (SVI) to 210mL/g with higher recovery of dry mass of sludge (87.25%) and water (50.3%).

  17. Blood coagulation and the risk of atherothrombosis: a complex relationship

    Directory of Open Access Journals (Sweden)

    van der Voort Danielle

    2004-12-01

    Full Text Available Abstract The principles of Virchov's triad appear to be operational in atherothrombosis or arterial thrombosis: local flow changes and particularly vacular wall damage are the main pathophysiological elements. Furthermore, alterations in arterial blood composition are also involved although the specific role and importance of blood coagulation is an ongoing matter of debate. In this review we provide support for the hypothesis that activated blood coagulation is an essential determinant of the risk of atherothrombotic complications. We distinguish two phases in atherosclerosis: In the first phase, atherosclerosis develops under influence of "classical" risk factors, i.e. both genetic and acquired forces. While fibrinogen/fibrin molecules participate in early plaque lesions, increased activity of systemic coagulation is of no major influence on the risk of arterial thrombosis, except in rare cases where a number of specific procoagulant forces collide. Despite the presence of tissue factor – factor VII complex it is unlikely that all fibrin in the atherosclerotic plaque is the direct result from local clotting activity. The dominant effect of coagulation in this phase is anticoagulant, i.e. thrombin enhances protein C activation through its binding to endothelial thrombomodulin. The second phase is characterized by advancing atherosclerosis, with greater impact of inflammation as indicated by an elevated level of plasma C-reactive protein, the result of increased production influenced by interleukin-6. Inflammation overwhelms protective anticoagulant forces, which in itself may have become less efficient due to down regulation of thrombomodulin and endothelial cell protein C receptor (EPCR expression. In this phase, the inflammatory drive leads to recurrent induction of tissue factor and assembly of catalytic complexes on aggregated cells and on microparticles, maintaining a certain level of thrombin production and fibrin formation. In advanced

  18. Does whole blood coagulation analysis reflect developmental haemostasis?

    DEFF Research Database (Denmark)

    Ravn, Hanne Berg; Andreasen, Jo Bønding; Hvas, Anne-Mette

    2017-01-01

    .05), but there was no sign of developmental changes in whole blood coagulation assessment when applying ROTEM, apart from clotting time in the EXTEM assay (P reach statistical significance. Citrate-anticoagulated blood showed...

  19. Synthetic profiles of polypeptides of human oocytes and normal and abnormal preimplantation embryos.

    Science.gov (United States)

    Capmany, G; Bolton, V N

    1999-09-01

    There is considerable variation in the rate of development in vitro of individual preimplantation human embryos. The relationship between the rate of development and patterns of polypeptide synthesis in individual embryos was examined using SDS-PAGE and autoradiography. After incubation in [35S]methionine, 19 polypeptide bands were identified that change between fertilization and the morula stage. Although changes in two of the bands occurred in embryos that were developing normally and in ageing oocytes, and are thus independent of fertilization, the changes identified in the remaining 17 bands occurred only after fertilization. In embryos that were developing abnormally, as assessed by delayed cleavage, cleavage arrest or extensive fragmentation, the alteration in polypeptide synthetic profiles increased with increasing abnormality.

  20. Coagulation-Fenton coupled treatment for ecotoxicity reduction in highly polluted industrial wastewater.

    Science.gov (United States)

    Perdigón-Melón, J A; Carbajo, J B; Petre, A L; Rosal, R; García-Calvo, E

    2010-09-15

    A coupled coagulation-Fenton process was applied for the treatment of cosmetic industry effluents. In a first step, FeSO(4) was used as coagulant and the non-precipitated Fe(2+) remaining in dissolution was used as catalyst in the further Fenton process. In the coagulation process a huge decrease in total organic carbon (TOC) was achieved, but the high concentration of phenol derivatives was not diminished. The decrease in TOC in the coagulation step significantly reduces the amount of H(2)O(2) required in the Fenton process for phenol depletion. The coupled process, using a H(2)O(2) dose of only 2 g l(-1), reduced TOC and total phenol to values lower than 40 and 0.10 mg l(-1), respectively. The short reaction period (less than 15 min) in TOC and phenol degradation bodes well for improving treatment in a continuous regime. The combination of both processes significantly reduced the ecotoxicity of raw effluent and markedly increased its biodegradability, thus allowing easier treatment by the conventional biological units in conventional sewage treatment plants (STPs). Copyright 2010 Elsevier B.V. All rights reserved.

  1. Ultrasound imaging of Nd:YAG laser-induced tissue coagulation in porcine livers.

    Science.gov (United States)

    Ritzel, U; Wietzke-Braun, P; Brinck, U; Leonhardt, U; Ramadori, G

    2001-12-01

    Absorption of laser light energy induces denaturation of proteins and thermocoagulation of irradiated tissue. Recently, MRI-guided laser coagulation in combination with MR thermometry was reported as a treatment of liver tumours. In the present study ultrasonographic imaging was evaluated for its suitability in laser induced tissue thermocoagulation. Fresh porcine livers were used for ex vivo examinations. Placement of the laser catheter and tissue coagulation during laser light emission were online monitored by ultrasonography. Nd:YAG laser-induced tissue damage was evaluated by macroscopical and microscopical examinations of histological sections. During laser light emission a marked hyperdense signal enhancement was observed by ultrasonography which strongly correlated with the extent of macroscopic tissue damage. The size of laser-induced coagulation zone depended on both the power setting and total energy delivered. Carbonization of the tissue surrounding the laser tip is a limiting factor because of laser light absorption. However our data indicate that using appropriate laser energy and exposure time prevent carbonization although carbonization can not be visualized by ultrasonography. It is concluded from the present ex vivo studies that laser coagulation can be effectively performed under ultrasonographic guidance.

  2. Cutting and coagulation during intraoral soft tissue surgery using Er: YAG laser.

    Science.gov (United States)

    Onisor, I; Pecie, R; Chaskelis, I; Krejci, I

    2013-06-01

    To find the optimal techniques and parameters that enables Er:YAG laser to be used successfully for small intraoral soft tissue interventions, in respect to its cutting and coagulation abilities. In vitro pre-tests: 4 different Er:YAG laser units and one CO2 unit as the control were used for incision and coagulation on porcine lower jaws and optimal parameters were established for each type of intervention and each laser unit: energy, frequency, type, pulse duration and distance. 3 different types of intervention using Er:YAG units are presented: crown lengthening, gingivoplasty and maxillary labial frenectomy with parameters found in the in vitro pre-tests. The results showed a great decrease of the EMG activity of masseter and anterior temporalis muscles. Moreover, the height and width of the chewing cycles in the frontal plane increased after therapy. Er:YAG is able to provide good cutting and coagulation effects on soft tissues. Specific parameters have to be defined for each laser unit in order to obtain the desired effect. Reduced or absent water spray, defocused light beam, local anaesthesia and the most effective use of long pulses are methods to obtain optimal coagulation and bleeding control.

  3. Extraction of natural coagulant from peanut seeds for treatment of turbid water

    International Nuclear Information System (INIS)

    Birima, A H; Desa, M N M; Muda, Z C; Hammad, H A

    2013-01-01

    This study investigates the potential of peanut seeds as an environmental friendly and natural coagulant for the treatment of high turbid water. The peanut seeds have been used after oil extraction; and the active coagulation component was extracted by distilled water and salt solution of different salt concentrations. The salts used were NaCl, KNO 3 , KCl, NH 4 Cl and NaNO 3 . Synthetic water with 200 NTU turbidity was used. Peanut extracted with NaCl (PC-NaCl) could effectively remove 92% of the 200 NTU turbidity using only 20 mg/l, while peanut seeds extracted with distilled water (PC-DW) could remove only 31.5% of the same turbidity with the same dosage. The coagulant dosage did not affected by the concentration of the salt solution, however, residual turbidity decreased with increasing the concentration of the salt; and the relationship was found to be a second order polynomial curve with R 2 of 0.9312. The other salts tested were also found to be good solvents to extract the active coagulation component with no much difference from NaCl solution in terms of efficiency.

  4. SYSTEM OF PRECISE DOSING OF COAGULANT IN THE PULVERIZING AERATOR POWERED BY WIND USING FUZZY LOGIC

    Directory of Open Access Journals (Sweden)

    Andrzej Osuch

    2017-06-01

    Full Text Available One of the methods used to support land restoration lakes is the method of pulverizing aeration. Use of aerators powered exclusively by wind improves the condition of reservoirs, while not compromising the environment. The pulverizing aeration process drive is windy on the water aeration zone near bottom, while removing harmful gases anaerobic metabolism. Aerators of this type due to the unique method of operation also enable dosing of inactivation coagulants with oxygenated water to the depths of the lake. Mileage coagulant dosing can be made dependent on the speed of the wind, which has an impact on the performance of his work, because with the increase of wind speed dispensing valve coagulants should be stronger open. One of the methods for assessing the state of lakes is to measure water transparency. The softer visibility, the most likely state of the water is better. Dosage of coagulant so you can make the transparency of the water. Similarly, with increasing transparency water dispensing valve should be more covered up. Control of the drain valve dispenser coagulant can be simultaneously dependent on two factors. The study was designed method of control drain valve dispenser coagulant using fuzzy inference.

  5. Studies on Removal of Dyes from wastewater using Electro-coagulation Process

    OpenAIRE

    N B. Patel; B D. Soni; J P. Ruparelia

    2000-01-01

    Electro-coagulation (EC) is one of the effective techniques to remove colour, COD and organic compounds from wastewater. In this paper electro coagulation technique has been used for the removal of colour and COD from dye solutions containing Direct Black 22 and Acid Red 97 using batch process. For batch the process effect of operational parameters such as current density, initial pH of the solution, time of electrolysis and electrode materials were studied to attempt max...

  6. Particle counter as a tool to control pre-hydrolyzed coagulant dosing and rapid filtration efficiency in a conventional treatment system.

    Science.gov (United States)

    Gumińska, Jolanta; Kłos, Marcin

    2015-01-01

    Filtration efficiency in a conventional water treatment system was analyzed in the context of pre-hydrolyzed coagulant overdosing. Two commercial coagulants of different aluminum speciation were tested. A study was carried out at a water treatment plant supplied with raw water of variable quality. The lack of stability of water quality caused many problems with maintaining the optimal coagulant dose. The achieved results show that the type of coagulant had a very strong influence on the effectiveness of filtration resulting from the application of an improper coagulant dose. The overdosing of high basicity coagulant (PAC85) caused a significant increase of fine particles in the outflow from the sedimentation tanks, which could not be retained in the filter bed due to high surface charge and the small size of hydrolysis products. When using a coagulant of lower basicity (PAC70), it was much easier to control the dose of coagulant and to adjust it to the changing water quality.

  7. Investigation of isolation conditions and ion-exchange purification of protein coagulation components from common bean seed

    Directory of Open Access Journals (Sweden)

    Antov Mirjana G.

    2007-01-01

    Full Text Available Investigation of an extraction procedure of protein coagulants from common bean seed regarding concentration of NaCl and pH was performed. High values of protein concentration and coagulation activity in crude extract (9.19 g/l and 23.9%, respectively were obtained when the extraction was performed using 0.5 mol/l NaCl and water as solvent, which represents an advantage for economic and environmental reasons. Crude extract of common bean seed was purified by precipitation at two different percentages of (NH42SO4 saturation, followed by batch ion-exchange chromatography. The highest obtained coagulation activity, 45%, was determined in fraction that was eluated at 1.75 mol/l NaCl from resin loaded with proteins precipitated upon 80-100% (NH42SO4 saturation. High values of coagulation activity showed by some eluates suggest their application as natural coagulant for water purification. .

  8. Enzymatic lipid oxidation by eosinophils propagates coagulation, hemostasis, and thrombotic disease

    Science.gov (United States)

    Uderhardt, Stefan; Ackermann, Jochen A.; Fillep, Tobias; Hammond, Victoria J.; Willeit, Johann; Stark, Konstantin; Rossaint, Jan; Schubert, Irene; Mielenz, Dirk; Dietel, Barbara; Raaz-Schrauder, Dorette; Ay, Cihan; Thaler, Johannes; Heim, Christian; Collins, Peter W.; Schabbauer, Gernot; Mackman, Nigel; Voehringer, David; Nadler, Jerry L.; Lee, James J.; Massberg, Steffen; Rauh, Manfred; O’Donnell, Valerie B.

    2017-01-01

    Blood coagulation is essential for physiological hemostasis but simultaneously contributes to thrombotic disease. However, molecular and cellular events controlling initiation and propagation of coagulation are still incompletely understood. In this study, we demonstrate an unexpected role of eosinophils during plasmatic coagulation, hemostasis, and thrombosis. Using a large-scale epidemiological approach, we identified eosinophil cationic protein as an independent and predictive risk factor for thrombotic events in humans. Concurrent experiments showed that eosinophils contributed to intravascular thrombosis by exhibiting a strong endogenous thrombin-generation capacity that relied on the enzymatic generation and active provision of a procoagulant phospholipid surface enriched in 12/15-lipoxygenase–derived hydroxyeicosatetraenoic acid–phosphatidylethanolamines. Our findings reveal a previously unrecognized role of eosinophils and enzymatic lipid oxidation as regulatory elements that facilitate both hemostasis and thrombosis in response to vascular injury, thus identifying promising new targets for the treatment of thrombotic disease. PMID:28566277

  9. Effects of coagulating enzyme types (commercial calf rennet ...

    African Journals Online (AJOL)

    Aysegul

    2013-09-11

    clotting enzyme in traditional cheese-making world- wide (Fox, 1987 ... Following pre-brining, the cheeses were packaged in plastic cups (1 kg) containing ..... study the differential degradation of αs-casein by various coagulants.

  10. The verification of the Taylor-expansion moment method for the nanoparticle coagulation in the entire size regime due to Brownian motion

    International Nuclear Information System (INIS)

    Yu Mingzhou; Lin Jianzhong; Jin Hanhui; Jiang Ying

    2011-01-01

    The closure of moment equations for nanoparticle coagulation due to Brownian motion in the entire size regime is performed using a newly proposed method of moments. The equations in the free molecular size regime and the continuum plus near-continuum regime are derived separately in which the fractal moments are approximated by three-order Taylor-expansion series. The moment equations for coagulation in the entire size regime are achieved by the harmonic mean solution and the Dahneke’s solution. The results produced by the quadrature method of moments (QMOM), the Pratsinis’s log-normal moment method (PMM), the sectional method (SM), and the newly derived Taylor-expansion moment method (TEMOM) are presented and compared in accuracy and efficiency. The TEMOM method with Dahneke’s solution produces the most accurate results with a high efficiency than other existing moment models in the entire size regime, and thus it is recommended to be used in the following studies on nanoparticle dynamics due to Brownian motion.

  11. Competing role of catalysis-coagulation and catalysis-fragmentation in kinetic aggregation behaviours

    International Nuclear Information System (INIS)

    Li Xiao-Dong; Lin Zhen-Quan; Song Mei-Xia; Ke Jian-Hong

    2010-01-01

    We propose a kinetic aggregation model where species A aggregates evolve by the catalysis-coagulation and the catalysis-fragmentation, while the catalyst aggregates of the same species B or C perform self-coagulation processes. By means of the generalized Smoluchowski rate equation based on the mean-field assumption, we study the kinetic behaviours of the system with the catalysis-coagulation rate kernel K(i,j;l) ∝ l ν and the catalysis-fragmentation rate kernel F(i,j;l) ∝ l μ , where l is the size of the catalyst aggregate, and ν and μ are two parameters reflecting the dependence of the catalysis reaction on the size of the catalyst aggregate. The relation between the values of parameters ν and μ reflects the competing roles between the two catalysis processes in the kinetic evolution of species A. It is found that the competing roles of the catalysis-coagulation and catalysis-fragmentation in the kinetic aggregation behaviours are not determined simply by the relation between the two parameters ν and μ, but also depend on the values of these two parameters. When ν > μ and ν ≥ 0, the kinetic evolution of species A is dominated by the catalysis-coagulation and its aggregate size distribution a k (t) obeys the conventional or generalized scaling law; when ν k (t) approaches the scale-free form; and in other cases, a balance is established between the two competing processes at large times and a k (t) obeys a modified scaling law. (cross-disciplinary physics and related areas of science and technology)

  12. Treatment of Surface water in lebanon by using the coagulation-flocculation procedure

    International Nuclear Information System (INIS)

    SLIM, K.; Saad, Z.; Kazpard, V.; El Samarani, A.

    2005-01-01

    In the absence of application of environmental protection laws in Lebanon. Anthropic effluents are directly discharged in the course of rivers. More specially two coastal rivers (GHadir and Ibrahim)located near Beirut. Treatment of these surface waters is done by coagulation-flocculation process by using Al13 coagulant. The elimination of suspended matters in Ghadir and Ibrahim rivers is studied by simple jar test coupled to measurement of supernatant turbidity and sediment volume. Physical and chemical parameters of water before and after treatment are given by Atomic absorption and ion chromatography analysis. The optimal coagulation concentration of Al was defined relatively to lowest concentration of Aluminum needed for maximum turbidity removal in treated water. This study showed that hydrolysis of aluminum salts before adding to water is relevant to the use of similar quantities of Al for the coagulation-flocculation process that eliminates primarily suspended matter in river. Restabilisation is shown in all Jar tests of Ibrahim river, but not in Ghadir where buffering effect is elevated. Results also showed that waters with low turbidity request low concentration of aluminum for the destabilization process. For this, Ibrahim water treatment was found better than river Ghadir characterized by higher inputs of anthropogenic effluents in its course. In all cases, cationic exchanges with Al 1 3 polycations within the sediments caused the release of calcium and the elevation of its concentration in the supernatant. Sulfate concentration diminished continuously in supernatant after the addition of the optimal coagulation concentration of aluminum. (author)

  13. Weighted Flow Algorithms (WFA) for stochastic particle coagulation

    International Nuclear Information System (INIS)

    DeVille, R.E.L.; Riemer, N.; West, M.

    2011-01-01

    Stochastic particle-resolved methods are a useful way to compute the time evolution of the multi-dimensional size distribution of atmospheric aerosol particles. An effective approach to improve the efficiency of such models is the use of weighted computational particles. Here we introduce particle weighting functions that are power laws in particle size to the recently-developed particle-resolved model PartMC-MOSAIC and present the mathematical formalism of these Weighted Flow Algorithms (WFA) for particle coagulation and growth. We apply this to an urban plume scenario that simulates a particle population undergoing emission of different particle types, dilution, coagulation and aerosol chemistry along a Lagrangian trajectory. We quantify the performance of the Weighted Flow Algorithm for number and mass-based quantities of relevance for atmospheric sciences applications.

  14. Weighted Flow Algorithms (WFA) for stochastic particle coagulation

    Science.gov (United States)

    DeVille, R. E. L.; Riemer, N.; West, M.

    2011-09-01

    Stochastic particle-resolved methods are a useful way to compute the time evolution of the multi-dimensional size distribution of atmospheric aerosol particles. An effective approach to improve the efficiency of such models is the use of weighted computational particles. Here we introduce particle weighting functions that are power laws in particle size to the recently-developed particle-resolved model PartMC-MOSAIC and present the mathematical formalism of these Weighted Flow Algorithms (WFA) for particle coagulation and growth. We apply this to an urban plume scenario that simulates a particle population undergoing emission of different particle types, dilution, coagulation and aerosol chemistry along a Lagrangian trajectory. We quantify the performance of the Weighted Flow Algorithm for number and mass-based quantities of relevance for atmospheric sciences applications.

  15. Slaughterhouse wastewater treatment by combined chemical coagulation and electrocoagulation process.

    Science.gov (United States)

    Bazrafshan, Edris; Kord Mostafapour, Ferdos; Farzadkia, Mehdi; Ownagh, Kamal Aldin; Mahvi, Amir Hossein

    2012-01-01

    Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD(5) removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater.

  16. Neuro-Coagulopathy: Blood Coagulation Factors in Central Nervous System Diseases.

    Science.gov (United States)

    De Luca, Ciro; Virtuoso, Assunta; Maggio, Nicola; Papa, Michele

    2017-10-12

    Blood coagulation factors and other proteins, with modulatory effects or modulated by the coagulation cascade have been reported to affect the pathophysiology of the central nervous system (CNS). The protease-activated receptors (PARs) pathway can be considered the central hub of this regulatory network, mainly through thrombin or activated protein C (aPC). These proteins, in fact, showed peculiar properties, being able to interfere with synaptic homeostasis other than coagulation itself. These specific functions modulate neuronal networks, acting both on resident (neurons, astrocytes, and microglia) as well as circulating immune system cells and the extracellular matrix. The pleiotropy of these effects is produced through different receptors, expressed in various cell types, in a dose- and time-dependent pattern. We reviewed how these pathways may be involved in neurodegenerative diseases (amyotrophic lateral sclerosis, Alzheimer's and Parkinson's diseases), multiple sclerosis, ischemic stroke and post-ischemic epilepsy, CNS cancer, addiction, and mental health. These data open up a new path for the potential therapeutic use of the agonist/antagonist of these proteins in the management of several central nervous system diseases.

  17. Slaughterhouse Wastewater Treatment by Combined Chemical Coagulation and Electrocoagulation Process

    Science.gov (United States)

    Bazrafshan, Edris; Kord Mostafapour, Ferdos; Farzadkia, Mehdi; Ownagh, Kamal Aldin; Mahvi, Amir Hossein

    2012-01-01

    Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD5 removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater. PMID:22768233

  18. Coagulation-agglomeration of fractal-like particles: structure and self-preserving size distribution.

    Science.gov (United States)

    Goudeli, Eirini; Eggersdorfer, Maximilian L; Pratsinis, Sotiris E

    2015-02-03

    Agglomeration occurs in environmental and industrial processes, especially at low temperatures where particle sintering or coalescence is rather slow. Here, the growth and structure of particles undergoing agglomeration (coagulation in the absence of coalescence, condensation, or surface growth) are investigated from the free molecular to the continuum regime by discrete element modeling (DEM). Particles coagulating in the free molecular regime follow ballistic trajectories described by an event-driven method, whereas in the near-continuum (gas-slip) and continuum regimes, Langevin dynamics describe their diffusive motion. Agglomerates containing about 10-30 primary particles, on the average, attain their asymptotic fractal dimension, D(f), of 1.91 or 1.78 by ballistic or diffusion-limited cluster-cluster agglomeration, corresponding to coagulation in the free molecular or continuum regimes, respectively. A correlation is proposed for the asymptotic evolution of agglomerate D(f) as a function of the average number of constituent primary particles, n̅(p). Agglomerates exhibit considerably broader self-preserving size distribution (SPSD) by coagulation than spherical particles: the number-based geometric standard deviations of the SPSD agglomerate radius of gyration in the free molecular and continuum regimes are 2.27 and 1.95, respectively, compared to ∼1.45 for spheres. In the transition regime, agglomerates exhibit a quasi-SPSD whose geometric standard deviation passes through a minimum at Knudsen number Kn ≈ 0.2. In contrast, the asymptotic D(f) shifts linearly from 1.91 in the free molecular regime to 1.78 in the continuum regime. Population balance models using the radius of gyration as collision radius underestimate (up to about 80%) the small tail of the SPSD and slightly overpredict the overall agglomerate coagulation rate, as they do not account for cluster interpenetration during coagulation. In the continuum regime, when a recently developed

  19. Performance of Solanum incunum Linnaeus as natural coagulant ...

    African Journals Online (AJOL)

    hope&shola

    2- concentrations for the treated water conforms to the Tanzanian Standards and WHO guidelines for drinking ... that S. incunum is promising as coagulant and disinfectant product for water purification. Key words: .... light greenish blue-grey.

  20. TREATMENT OF LANDFILL LEACHATE BY COUPLING COAGULATION-FLOCCULATION OR OZONATION TO GRANULAR ACTIVATED CARBON ADSORPTION.

    Science.gov (United States)

    Oloibiri, Violet; Ufomba, Innocent; Chys, Michael; Audenaert, Wim; Demeestere, Kristof; Van Hulle, Stijn W H

    2015-01-01

    A major concern for landfilling facilities is the treatment of their leachate. To optimize organic matter removal from this leachate, the combination of two or more techniques is preferred in order to meet stringent effluent standards. In our study, coagulation-flocculation and ozonation are compared as pre- treatment steps for stabilized landfill leachate prior to granular activated carbon (GAC) adsorption. The efficiency of the pre treatment techniques is evaluated using COD and UVA254 measurements. For coagulation- flocculation, different chemicals are compared and optimal dosages are determined. After this, iron (III) chloride is selected for subsequent adsorption studies due to its high percentage of COD and UVA254 removal and good sludge settle-ability. Our finding show that ozonation as a single treatment is effective in reducing COD in landfill leachate by 66% compared to coagulation flocculation (33%). Meanwhile, coagulation performs better in UVA254 reduction than ozonation. Subsequent GAC adsorption of ozonated effluent, coagulated effluent and untreated leachate resulted in 77%, 53% and 8% total COD removal respectively (after 6 bed volumes). The effect of the pre-treatment techniques on GAC adsorption properties is evaluated experimentally and mathematically using Thomas and Yoon-Nelson models. Mathematical modelling of the experimental GAC adsorption data shows that ozonation increases the adsorption capacity and break through time with a factor of 2.5 compared to coagulation-flocculation.

  1. Autovalidation and automation of the postanalytical phase of routine hematology and coagulation analyses in a university hospital laboratory.

    Science.gov (United States)

    Mlinaric, Ana; Milos, Marija; Coen Herak, Désirée; Fucek, Mirjana; Rimac, Vladimira; Zadro, Renata; Rogic, Dunja

    2018-02-23

    The need to satisfy high-throughput demands for laboratory tests continues to be a challenge. Therefore, we aimed to automate postanalytical phase in hematology and coagulation laboratory by autovalidation of complete blood count (CBC) and routine coagulation test results (prothrombin time [PT], international normalized ratio [PT-INR], activated partial thromboplastin time [APTT], fibrinogen, antithrombin activity [AT] and thrombin time [TT]). Work efficacy and turnaround time (TAT) before and after implementation of automated solutions will be compared. Ordering panels tailored to specific patient populations were implemented. Rerun and reflex testing rules were set in the respective analyzers' software (Coulter DxH Connectivity 1601, Beckman Coulter, FL, USA; AutoAssistant, Siemens Healthcare Diagnostics, Germany), and sample status information was transferred into the laboratory information system. To evaluate if the automation improved TAT and efficacy, data from manually verified results in September and October of 2015 were compared with the corresponding period in 2016 when autovalidation was implemented. Autovalidation rates of 63% for CBC and 65% for routine coagulation test results were achieved. At the TAT of 120 min, the percentage of reported results increased substantially for all analyzed tests, being above 90% for CBC, PT, PT-INR and fibrinogen and 89% for APTT. This output was achieved with three laboratory technicians less compared with the period when the postanalytical phase was not automated. Automation allowed optimized laboratory workflow for specific patient populations, thereby ensuring standardized results reporting. Autovalidation of test results proved to be an efficient tool for improvement of laboratory work efficacy and TAT.

  2. Temperature effects on flocculation, using different coagulants.

    Science.gov (United States)

    Fitzpatrick, C S B; Fradin, E; Gregory, J

    2004-01-01

    Temperature is known to affect flocculation and filter performance. Jar tests have been conducted in the laboratory, using a photometric dispersion analyser (PDA) to assess the effects of temperature on floc formation, breakage and reformation. Alum, ferric sulphate and three polyaluminium chloride (PACI) coagulants have been investigated for temperatures ranging between 6 and 29 degrees C for a suspension of kaolin clay in London tap water. Results confirm that floc formation is slower at lower temperatures for all coagulants. A commercial PACl product, PAX XL 19, produces the largest flocs for all temperatures; and alum the smallest. Increasing the shear rate results in floc breakage in all cases and the flocs never reform to their original size. This effect is most notable for temperatures around 15 degrees C. Breakage, in terms of floc size reduction, is greater for higher temperatures, suggesting a weaker floc. Recovery after increased shear is greater at lower temperatures implying that floc break-up is more reversible for lower temperatures.

  3. Comparative Evaluation of Aluminum Sulfate and Ferric Sulfate-Induced Coagulations as Pretreatment of Microfiltration for Treatment of Surface Water

    Directory of Open Access Journals (Sweden)

    Yali Song

    2015-06-01

    Full Text Available Two coagulants, aluminum sulfate and ferric chloride, were tested to reduce natural organic matter (NOM as a pretreatment prior to polyvinylidene fluoride (PVDF microfiltration (MF membranes for potable water treatment. The results showed that the two coagulants exhibited different treatment performance in NOM removal. Molecular weight (MW distributions of NOM in the tested surface raw water were concentrated at 3–5 kDa and approximately 0.2 kDa. Regardless of the coagulant species and dosages, the removal of 0.2 kDa NOM molecules was limited. In contrast, NOM at 3–5 kDa were readily removed with increasing coagulant dosages. In particular, aluminum sulfate favorably removed NOM near 5 kDa, whereas ferric chloride tended to reduce 3 kDa organic substances. Although aluminum sulfate and ferric chloride could improve the flux of the ensuing MF treatment, the optimal coagulant dosages to achieve effective pretreatment were different: 2–30 mg/L for aluminum sulfate and >15 mg/L for ferric chloride. The scanning electron microscope (SEM image of the membrane-filtered coagulated raw water showed that coagulation efficiency dramatically affected membrane flux and that good coagulation properties can reduce membrane fouling.

  4. Anti-Coagulant and Anti-Thrombotic Properties of Blacklip Abalone (Haliotis rubra): In Vitro and Animal Studies.

    Science.gov (United States)

    Suleria, Hafiz Ansar Rasul; Masci, Paul P; Zhao, Kong-Nan; Addepalli, Rama; Chen, Wei; Osborne, Simone A; Gobe, Glenda C

    2017-08-04

    Sulphated polysaccharides with anti-thrombotic and anti-coagulant activities have been found in various marine biota. In this study, a previously characterised anti-thrombotic and anti-coagulant extract from blacklip abalone was fractionated by anion exchange chromatography (AEC), pooled (on a sulphated polysaccharide basis) and administered to Wistar rats via oral gavage (N = 8) for assessment as an oral therapeutic. To ensure that the preparation had anti-coagulant activity prior to oral administration, it was assessed in rat blood by thromboelastography (TEG) significantly increasing reaction (R) time (or time until clot formation). Following in vitro confirmation of anti-coagulant activity, 40 mg of the preparation was orally administered to rats with blood samples collected at 2, 4, and 6 h post-gavage. Assessment of all blood samples by TEG showed some prolongation of R time from 355 to 380 s after 4 h. Dosing of the post-gavage blood samples with the abalone preparation to confirm anti-thrombotic activity in vitro revealed residual anti-coagulant activity, further suggesting that oral administration did increase anti-coagulant potential in the collected blood but that bioavailability was low. Assessment of tissues and haematological parameters showed no obvious harmful effects of the abalone preparation in animals. In summary, even though oral administration of fractionated and pooled blacklip abalone extract to rats delayed clotting after 4 h, bioavailability of the preparation appeared to be low and may be more appropriate for intravenous administration as an anti-thrombotic or anti-coagulant therapeutic.

  5. EVALUATION OF FERRIC CHLORIDE AND ALUM EFFICIENCIES IN ENHANCED COAGULATION FOR TOC REMOVAL AND RELATED RESIDUAL METAL CONCENTRATIONS

    Directory of Open Access Journals (Sweden)

    A. Mesdaghinia, M. T. Rafiee, F. Vaezi and A. H. Mahvi

    2005-07-01

    Full Text Available Although the removal of colloidal particles continues to be an important reason for using coagulation, a newer objective, the removal of natural organic matter (NOM to reduce the formation of disinfection by-products (DBPs, is growing in importance. Enhanced coagulation is thus introduced to most water utilities treating surface water. Bench-scale experiments were conducted to compare the effectiveness of alum and ferric chloride in removing DBPs precursors from eight synthetic water samples, each representing a different element of the USEPA’s 3×3 enhanced coagulation matrix. The effect of enhanced coagulation on the residual metal (aluminum/iron concentration in the treated water was assessed as well. The removal of total organic carbon (TOC was dependent on the coagulant type and was enhanced with increasing coagulant dose, but the latter had no further considerable effect in case of increasing to high levels. For all the treated samples coagulation with ferric chloride proved to be more effective than alum at similar doses and the mean values of treatment efficiencies were 51% and 32% for ferric chloride and alum, respectively. Ferric chloride was therefore considered the better chemical for enhancing the coagulation process. Besides, due to less production of sludge by this coagulant, it would be predicted that treatment plants would be confronted to fewer problems with respect to final sludge disposal. Measurements of residual metal in treated water indicated that iron and aluminum concentrations had been increased as expected but the quality of water concerning the residual metal deteriorated much more in cases of under-dosing. Despite expecting high residual Al and Fe concentrations under enhanced coagulation, metal concentrations were frequently remained low and were not increased appreciably.

  6. SignalSpider: Probabilistic pattern discovery on multiple normalized ChIP-Seq signal profiles

    KAUST Repository

    Wong, Kachun

    2014-09-05

    Motivation: Chromatin immunoprecipitation (ChIP) followed by high-throughput sequencing (ChIP-Seq) measures the genome-wide occupancy of transcription factors in vivo. Different combinations of DNA-binding protein occupancies may result in a gene being expressed in different tissues or at different developmental stages. To fully understand the functions of genes, it is essential to develop probabilistic models on multiple ChIP-Seq profiles to decipher the combinatorial regulatory mechanisms by multiple transcription factors. Results: In this work, we describe a probabilistic model (SignalSpider) to decipher the combinatorial binding events of multiple transcription factors. Comparing with similar existing methods, we found SignalSpider performs better in clustering promoter and enhancer regions. Notably, SignalSpider can learn higher-order combinatorial patterns from multiple ChIP-Seq profiles. We have applied SignalSpider on the normalized ChIP-Seq profiles from the ENCODE consortium and learned model instances. We observed different higher-order enrichment and depletion patterns across sets of proteins. Those clustering patterns are supported by Gene Ontology (GO) enrichment, evolutionary conservation and chromatin interaction enrichment, offering biological insights for further focused studies. We also proposed a specific enrichment map visualization method to reveal the genome-wide transcription factor combinatorial patterns from the models built, which extend our existing fine-scale knowledge on gene regulation to a genome-wide level. Availability and implementation: The matrix-algebra-optimized executables and source codes are available at the authors\\' websites: http://www.cs.toronto.edu/∼wkc/SignalSpider. Contact: Supplementary information: Supplementary data are available at Bioinformatics online.

  7. Rapid removal of fine particles from mine water using sequential processes of coagulation and flocculation

    Energy Technology Data Exchange (ETDEWEB)

    Jang, M.; Lee, H.J.; Shim, Y. [Korean Mine Reclamation Corporation MIRECO, Seoul (Republic of Korea)

    2010-07-01

    The processes of coagulation and flocculation using high molecular weight long-chain polymers were applied to treat mine water having fine flocs of which about 93% of the total mass was less than 3.02 {mu} m, representing the size distribution of fine particles. Six different combinations of acryl-type anionic flocculants and polyamine-type cationic coagulants were selected to conduct kinetic tests on turbidity removal in mine water. Optimization studies on the types and concentrations of the coagulant and flocculant showed that the highest rate of turbidity removal was obtained with 10 mg L{sup -1} FL-2949 (coagulant) and 12 mg L{sup -1} A333E (flocculant), which was about 14.4 and 866.7 times higher than that obtained with A333E alone and that obtained through natural precipitation by gravity, respectively. With this optimized condition, the turbidity of mine water was reduced to 0 NTU within 20 min. Zeta potential measurements were conducted to elucidate the removal mechanism of the fine particles, and they revealed that there was a strong linear relationship between the removal rate of each pair of coagulant and flocculant application and the zeta potential differences that were obtained by subtracting the zeta potential of flocculant-treated mine water from the zeta potential of coagulant-treated mine water. Accordingly, through an optimization process, coagulation-flocculation by use of polymers could be advantageous to mine water treatment, because the process rapidly removes fine particles in mine water and only requires a small-scale plant for set-up purposes owing to the short retention time in the process.

  8. Infrared coagulation versus rubber band ligation in early stage hemorrhoids.

    Science.gov (United States)

    Gupta, P J

    2003-10-01

    The ideal therapy for early stages of hemorrhoids is always debated. Some are more effective but are more painful, others are less painful but their efficacy is also lower. Thus, comfort or efficacy is a major concern. In the present randomized study, a comparison is made between infrared coagulation and rubber band ligation in terms of effectiveness and discomfort. One hundred patients with second degree bleeding piles were randomized prospectively to either rubber band ligation (N = 54) or infrared coagulation (N = 46). Parameters measured included postoperative discomfort and pain, time to return to work, relief in incidence of bleeding, and recurrence rate. The mean age was 38 years (range 19-68 years). The mean duration of disease was 17.5 months (range 12 to 34 months). The number of male patients was double that of females. Postoperative pain during the first week was more intense in the band ligation group (2-5 vs 0-3 on a visual analogue scale). Post-defecation pain was more intense with band ligation and so was rectal tenesmus (P = 0.0059). The patients in the infrared coagulation group resumed their duties earlier (2 vs 4 days, P = 0.03), but also had a higher recurrence or failure rate (P = 0.03). Thus, we conclude that band ligation, although more effective in controlling symptoms and obliterating hemorrhoids, is associated with more pain and discomfort to the patient. As infrared coagulation can be conveniently repeated in case of recurrence, it could be considered to be a suitable alternative office procedure for the treatment of early stage hemorrhoids.

  9. Treatment of the oily produced water (OPW using coagulant mixtures

    Directory of Open Access Journals (Sweden)

    R. Hosny

    2016-09-01

    Full Text Available Treatment of the oily produced water (OPW before injection into oil reservoirs is necessary to reduce formation damage. This can be done using chemo-physical process to minimize the oil droplets in water. In this respect, this work aims to extract natural polymer (chitosan from shrimp shells and mix it with coagulants (chitosan/carboxy methyl cellulose and chitosan/aluminum sulfate to adsorb oil from OPW. Adsorption experiments were carried out in batch mode firstly to choose the best coagulants in water treatment, also to investigate the effects of pH on the adsorption uptake, adsorbent dosage, coagulant mixture doses and contact time. It was found that the oil removal by chitosan reached 96.35% and 59% at pH = 4 and pH = 9, respectively. The ability of chitosan to remove oil was increased after adding different coagulants CMC/or aluminum sulfate at average mixing time between 30 and 60 min. It was also found that the highest removal efficiency of chitosan/CMC is 99% at (90% chitosan: 10% CMC and chitosan/Al2(SO43 is 85% at (80% chitosan: 20% Al2(SO43. The SEM photographs of chitosan, chitosan/CMC and chitosan/Al2(SO43 mixture as oil removal showed that chitosan/Al2(SO43 lies between chitosan alone and chitosan/CMC mixture. Generally chitosan/CMC characterized significantly by its high ability to adsorb petroleum oil and suspended solids from OPW, additionally, reduces the economic cost of water treatment.

  10. Origin of serpin-mediated regulation of coagulation and blood pressure.

    Directory of Open Access Journals (Sweden)

    Yunjie Wang

    Full Text Available Vertebrates evolved an endothelium-lined hemostatic system and a pump-driven pressurized circulation with a finely-balanced coagulation cascade and elaborate blood pressure control over the past 500 million years. Genome analyses have identified principal components of the ancestral coagulation system, however, how this complex trait was originally regulated is largely unknown. Likewise, little is known about the roots of blood pressure control in vertebrates. Here we studied three members of the serpin superfamily that interfere with procoagulant activity and blood pressure of lampreys, a group of basal vertebrates. Angiotensinogen from these jawless fish was found to fulfill a dual role by operating as a highly selective thrombin inhibitor that is activated by heparin-related glycosaminoglycans, and concurrently by serving as source of effector peptides that activate type 1 angiotensin receptors. Lampreys, uniquely among vertebrates, thus use angiotensinogen for interference with both coagulation and osmo- and pressure regulation. Heparin cofactor II from lampreys, in contrast to its paralogue angiotensinogen, is preferentially activated by dermatan sulfate, suggesting that these two serpins affect different facets of thrombin's multiple roles. Lampreys also express a lineage-specific serpin with anti-factor Xa activity, which demonstrates that another important procoagulant enzyme is under inhibitory control. Comparative genomics suggests that orthologues of these three serpins were key components of the ancestral hemostatic system. It appears that, early in vertebrate evolution, coagulation and osmo- and pressure regulation crosstalked through antiproteolytically active angiotensinogen, a feature that was lost during vertebrate radiation, though in gnathostomes interplay between these traits is effective.

  11. Elimination of man-made radionuclides from natural waters by applying a standard coagulation-flocculation process

    International Nuclear Information System (INIS)

    Baeza, A.; Miro, C.; Salas, A.; Fernandez, M.; Herranz, M.; Legarda, F.

    2004-01-01

    Effectiveness of potable water treatment processes that consist of the stages of coagulation-flocculation-decantation, using iron-based coagulants, in eliminating gamma-emitting man-made radioisotopes of cesium, strontium, and americium from two natural waters with different degrees of mineralization was studied. The resulting decontamination was found to depend on the chemical behavior of each of the radionuclides considered, on the pH at which the process of coagulation is carried out, and on the concentration of the other stable cations present. (author)

  12. Risk of disseminated intravascular coagulation in patients undergoing US-guided transperineal prostatic biopsy

    International Nuclear Information System (INIS)

    Stella, M.S.; Comparato, D.; Camici, M.; Evangelisti, L.; Gaudio, V.; De Negri, F.; Talarico, L.; Giusti, C.; Morelli, G.

    1991-01-01

    Disseminated intravascular coagulation (DIC) is a severe life-threatening acute bleeding disorder. Traumatized tissues, tumors, necrotic tissues, or bacterial endotoxines release similar material in the blood to the tissutal factors activating the coagulation cascade. This preliminary study was aimed at verifying the risk of DIV in patients undergoing US-guided transperineal prostatic biopsy with Chiba and Tru-Cut needles. To evaluate the activation degree of coagulation factors in the circulation, the authors measured the concentrations of urinary fibrin degradation products in 10 patients undergoing US-guided transperineal prostatic biopsy, both before and after biopsy, every second hour, for 24 hours. Every tube of urine sample contained soya bean trypsin inhibitor and bovine thrombin to prevent any further fibrin degradation during incubation period for the possible presence of blood in urine samples. The results showed that 7/10 patients had marked increase in urinary fibrin degradation product levels (up to 800 XXXX%), with a 3-phase trend: early peak after 2-6 hours, middle peak after 6-14 hours, and late peak after 18-24 hours, which proved the activation of the coagulation cascade

  13. Experimental investigation and modeling of dissolved organic carbon removal by coagulation from seawater.

    Science.gov (United States)

    Jeong, Sanghyun; Sathasivan, Arumugam; Kastl, George; Shim, Wang Geun; Vigneswaran, Saravanamuthu

    2014-01-01

    Coagulation removes colloidal matters and dissolved organic carbon (DOC) which can cause irreversible membrane fouling. However, how DOC is removed by coagulant is not well-known. Jar test was used to study the removal of hydrophobic and hydrophilic DOC fractions at various doses (0.5-8.0 mg-Fe(+3) L(-1)) of ferric chloride (FeCl3) and pH (5.0-9.0). Natural organic matter (NOM) in seawater and treated seawater were fractionated by liquid chromatography-organic carbon detector (LC-OCD). Compared to surface water, the removal of DOC in seawater by coagulation was remarkably different. Majority of DOC could be easily removed with very low coagulant dose (fraction (HB) was better removed at high pH while hydrophilic fraction (HF) was better removed at low pH. A modified model of Kastl et al. (2004) which assumed that the removal occurred by adsorption of un-dissociated compounds onto ferric hydroxide was formulated and successfully validated against the jar test data. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Rheological behavior of raw natural rubber coagulated by microorganisms

    Directory of Open Access Journals (Sweden)

    Zhifen Wang

    2014-01-01

    Full Text Available Tests of the strain sweep, frequency sweep and stress relaxation for raw natural rubber coagulated by microorganisms (NR-m and raw natural rubber coagulated by acid (NR-a were carried out with the use of a rubber process analyzer (RPA. The results showed that the storage torque, complex viscosity of NR-m were higher than those of NR-a while the loss factor was lower. The effect of temperature on viscosity of raw NR was studied following the Arrhenious-Frenkel-Eyring model. The viscous flow behavior of NR-m was poorer than those of NR-a. Furthermore, stress relaxation measurements of raw NR showed a longer period of relaxation for NR-m.

  15. Engineering the substrate and inhibitor specificities of human coagulation Factor VIIa

    DEFF Research Database (Denmark)

    Larsen, Katrine S; Østergaard, Henrik; Bjelke, Jais R

    2007-01-01

    The remarkably high specificity of the coagulation proteases towards macromolecular substrates is provided by numerous interactions involving the catalytic groove and remote exosites. For FVIIa [activated FVII (Factor VII)], the principal initiator of coagulation via the extrinsic pathway, several...... for FVIIa by marked changes in primary substrate specificity and decreased rates of antithrombin III inhibition. Interestingly, these changes do not necessarily coincide with an altered ability to activate Factor X, demonstrating that inhibitor and macromolecular substrate selectivity may be engineered...

  16. Early activation of the coagulation system during lower body negative pressure

    DEFF Research Database (Denmark)

    Zaar, M; Johansson, P I; Nielsen, L B

    2009-01-01

    We considered that a moderate reduction of the central blood volume (CBV) may activate the coagulation system. Lower body negative pressure (LBNP) is a non-invasive means of reducing CBV and, thereby, simulates haemorrhage. We tested the hypothesis that coagulation markers would increase following...... moderate hypovolemia by exposing 10 healthy male volunteers to 10 min of 30 mmHg LBNP. Thoracic electrical impedance increased during LBNP (by 2.6 +/- 0.7 Omega, mean +/- SD; P pressure decreased (84 +/- 5 to 80...

  17. Chitosan as coagulant on cyanobacteria in lake restoration management may cause rapid cell lysis

    NARCIS (Netherlands)

    Mucci, Maira; Noyma, Natalia Pessoa; de Magalhaes, Leonardo; Miranda, Marcela; van Oosterhout, Frank; Guedes, Iame Alves; Huszar, Vera L. M.; Marinho, Marcelo Manzi; Lürling, Miquel

    2017-01-01

    Combining coagulant and ballast to remove cyanobacteria from the water column is a promising restoration technique to mitigate cyanobacterial nuisance in surface waters. The organic, biodegradable polymer chitosan has been promoted as a coagulant and is viewed as non-toxic. In this study, we show

  18. Coagulation Status in Hidradenitis Suppurativa

    DEFF Research Database (Denmark)

    Miller, Iben Marie; Johansen, Maria Egede; Mogensen, Ulla B

    2015-01-01

    BACKGROUND: Chronic inflammatory diseases other than hidradenitis suppurativa (HS) have been associated with prothrombotic/hypercoagulable status. OBJECTIVE: To investigate a possible association between the chronic inflammatory skin disease HS and prothrombotic/hypercoagulable state. METHODS: We.......3432). CONCLUSION: We did not find an association between HS and prothrombotic/hypercoagulable status. Thus, thrombocytes may not be activated in HS. Furthermore, INR may not be affected in HS, suggesting that intrinsic and vitamin K-dependent coagulation factors appear unaffected....

  19. Coagulation effectiveness of graphene oxide for the removal of turbidity from raw surface water.

    Science.gov (United States)

    Aboubaraka, Abdelmeguid E; Aboelfetoh, Eman F; Ebeid, El-Zeiny M

    2017-08-01

    This study presents the performance of graphene oxide (GO) as a coagulant in turbidity removal from naturally and artificially turbid raw surface water. GO is considered an excellent alternative to alum, the more common coagulant used in water treatment processes, to reduce the environmental release of aluminum. Effects of GO dosage, pH, and temperature on its coagulation ability were studied to determine the ideal turbidity removal conditions. The turbidity removal was ≥95% for all levels of turbid raw surface water (20, 100, and 200 NTU) at optimum conditions. The role of alkalinity in inducing turbidity removal by GO coagulation was much more pronounced upon using raw surface water samples compared with that using artificially turbid deionized water samples. Moreover, GO demonstrated high-performance removal of biological contaminants such as algae, heterotrophic bacteria, and fecal coliform bacteria by 99.0%, 98.8% and 96.0%, respectively, at a dosage of 40 mg/L. Concerning the possible environmental release of GO into the treated water following filtration process, there was no residual GO in a wide range of pH values. The outcomes of the study highlight the excellent coagulation performance of GO for the removal of turbidity and biological contaminants from raw surface water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Removal of arsenic and iron removal from drinking water using coagulation and biological treatment.

    Science.gov (United States)

    Pramanik, Biplob Kumar; Pramanik, Sagor Kumar; Suja, Fatihah

    2016-02-01

    Effects of biological activated carbon (BAC), biological aerated filter (BAF), alum coagulation and Moringa oleifera coagulation were investigated to remove iron and arsenic contaminants from drinking water. At an initial dose of 5 mg/L, the removal efficiency for arsenic and iron was 63% and 58% respectively using alum, and 47% and 41% respectively using Moringa oleifera. The removal of both contaminants increased with the increase in coagulant dose and decrease in pH. Biological processes were more effective in removing these contaminants than coagulation. Compared to BAF, BAC gave greater removal of both arsenic and iron, removing 85% and 74%, respectively. Longer contact time for both processes could reduce the greater concentration of arsenic and iron contaminants. The addition of coagulation (at 5 mg/L dosage) and a biological process (with 15 or 60 min contact time) could significantly increase removal efficiency, and the maximum removal was observed for the combination of alum and BAC treatment (60 min contact time), with 100% and 98.56% for arsenic and iron respectively. The reduction efficiency of arsenic and iron reduced with the increase in the concentration of dissolved organics in the feedwater due to the adsorption competition between organic molecules and heavy metals.

  1. Condutivity effect in electro-coagulation-flotation applied to physico-chemical wastewater treatment

    OpenAIRE

    Francisco Javier Cuba Terán; Mário Luiz Rodrigues Foco

    2007-01-01

    This study reports on the effect of conductivity on the simultaneous applicability of water electrolysis , chemical coagulation and flotation fundamentals in the treatment of wastewater with large amounts of suspended matter, characterizing electro-coagulation-flotation (ECF) . Results from experiments carried out in a pilot study implanted and operated in the Laboratory of Environment Control (LCA), at the State University of Campinas in Limeira are presented. ECF was developed in an electro...

  2. Simple luminosity normalization of greenness, yellowness and redness/greenness for comparison of leaf spectral profiles in multi-temporally acquired remote sensing images.

    Science.gov (United States)

    Doi, Ryoichi

    2012-09-01

    Observation of leaf colour (spectral profiles) through remote sensing is an effective method of identifying the spatial distribution patterns of abnormalities in leaf colour, which enables appropriate plant management measures to be taken. However, because the brightness of remote sensing images varies with acquisition time, in the observation of leaf spectral profiles in multi-temporally acquired remote sensing images, changes in brightness must be taken into account. This study identified a simple luminosity normalization technique that enables leaf colours to be compared in remote sensing images over time. The intensity values of green and yellow (green+red) exhibited strong linear relationships with luminosity (R2 greater than 0.926) when various invariant rooftops in Bangkok or Tokyo were spectralprofiled using remote sensing images acquired at different time points. The values of the coefficient and constant or the coefficient of the formulae describing the intensity of green or yellow were comparable among the single Bangkok site and the two Tokyo sites, indicating the technique's general applicability. For single rooftops, the values of the coefficient of variation for green, yellow, and red/green were 16% or less (n=6-11), indicating an accuracy not less than those of well-established remote sensing measures such as the normalized difference vegetation index. After obtaining the above linear relationships, raw intensity values were normalized and a temporal comparison of the spectral profiles of the canopies of evergreen and deciduous tree species in Tokyo was made to highlight the changes in the canopies' spectral profiles. Future aspects of this technique are discussed herein.

  3. Management of familial Mediterranean fever by colchicine does not normalize the altered profile of microbial long chain fatty acids in the human metabolome

    Directory of Open Access Journals (Sweden)

    Zhanna eKtsoyan

    2013-01-01

    Full Text Available In our previous works we established that in an autoinflammatory condition, familial Mediterranean fever, the gut microbial diversity is specifically restructured, which also results in the altered profiles of microbial long chain fatty acids (LCFAs present in the systemic metabolome. The mainstream management of the disease is based on oral administration of colchicine to suppress clinical signs and extend remission periods and our aim was to determine whether this therapy normalizes the microbial LCFA profiles in the metabolome as well. Unexpectedly, the treatment does not normalize these profiles. Moreover, it results in the formation of new distinct microbial LCFA clusters, which are well separated from the corresponding values in healthy controls and FMF patients without the therapy. We hypothesize that the therapy alters the proinflammatory network specific for the disease, with the concomitant changes in gut microbiota and the corresponding microbial LCFAs in the metabolome.

  4. Cancer associated epigenetic transitions identified by genome-wide histone methylation binding profiles in human colorectal cancer samples and paired normal mucosa

    International Nuclear Information System (INIS)

    Enroth, Stefan; Rada-Iglesisas, Alvaro; Andersson, Robin; Wallerman, Ola; Wanders, Alkwin; Påhlman, Lars; Komorowski, Jan; Wadelius, Claes

    2011-01-01

    Despite their well-established functional roles, histone modifications have received less attention than DNA methylation in the cancer field. In order to evaluate their importance in colorectal cancer (CRC), we generated the first genome-wide histone modification profiles in paired normal colon mucosa and tumor samples. Chromatin immunoprecipitation and microarray hybridization (ChIP-chip) was used to identify promoters enriched for histone H3 trimethylated on lysine 4 (H3K4me3) and lysine 27 (H3K27me3) in paired normal colon mucosa and tumor samples from two CRC patients and for the CRC cell line HT29. By comparing histone modification patterns in normal mucosa and tumors, we found that alterations predicted to have major functional consequences were quite rare. Furthermore, when normal or tumor tissue samples were compared to HT29, high similarities were observed for H3K4me3. However, the differences found for H3K27me3, which is important in determining cellular identity, indicates that cell lines do not represent optimal tissue models. Finally, using public expression data, we uncovered previously unknown changes in CRC expression patterns. Genes positive for H3K4me3 in normal and/or tumor samples, which are typically already active in normal mucosa, became hyperactivated in tumors, while genes with H3K27me3 in normal and/or tumor samples and which are expressed at low levels in normal mucosa, became hypersilenced in tumors. Genome wide histone modification profiles can be used to find epigenetic aberrations in genes associated with cancer. This strategy gives further insights into the epigenetic contribution to the oncogenic process and may identify new biomarkers

  5. Chitosan as coagulant on cyanobacteria in lake restoration management may cause rapid cell lysis

    NARCIS (Netherlands)

    Nunes Teixeira Mucci, Maira; Noyma, Natalia Pessoa; Magalhães, de Leonardo; Miranda, Marcela; Oosterhout, van Frank; Guedes, Iamê Alves; Huszar, Vera L.M.; Marinho, Marcelo Manzi; Lürling, Miquel

    2017-01-01

    Combining coagulant and ballast to remove cyanobacteria from the water column is a promising restoration technique to mitigate cyanobacterial nuisance in surface waters. The organic, biodegradable polymer chitosan has been promoted as a coagulant and is viewed as non-toxic. In this study, we show

  6. Treatment of Industrial Liquid Waste of Steel Plating by Coagulation-Flocculation Using Sodium Biphosphate

    International Nuclear Information System (INIS)

    Subiarto; Herlan Martono

    2007-01-01

    Research about treatment of industrial liquid waste of steel plating by coagulation-flocculation using sodium biphosphate have been conducted. The purpose of the treatment was the content reduction of Cr, Ni, and Cu in the liquid waste, so that produced effluent with Cr, Ni, and Cu content until they laid under mutual standard. The variables studied in this process were the solution pH, the coagulant/waste volume comparison, the speed of the fast stirring, and the time of the fast stirring. Optimum separation efficiency on coagulation-flocculation process of liquid waste of steel plating using sodium biphosphate at the condition of solution ph 9, coagulant/waste volume comparation 1.50, the speed of the fast stirring 400 rpm, and the time of fast stirring is 5 minute. Low stirring was conducted at 60 rpm for 60 minute. The yields of optimum separation efficiency in this condition were 99.48 % for Cr, 99.51 % for Ni, and 99.03 % for Cu. (author)

  7. Study of coagulant development and the characteristics for the treatment of tire remanufacturing wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, E.S.; Yoon, I.M. [School of Natural Sciences, Honam Univ., Gwangju (Korea)

    2005-07-01

    This study was conducted to test the performance of various combinations of coagulants for effective wastewater treatment of the tire recycling industry. From the jar-test results, two kinds of coagulants, namely AlSi-1 and PASi-1, were found to be effective in decreasing BOD and COD{sub Cr} values from the polluted wastewater among various combinations of coagulants. In comparison to Al-based or Si-based singular salts, the Si-Al combined salts (PASi-1) exhibited a higher removal efficiency of 90% turbidity, 93% SS, 70 {proportional_to} 85% BOD{sub 5} and 85 {proportional_to} 91% COD{sub Cr} at 15 {+-} 2 C, pH7.5 {proportional_to} 9.5 and 2.0 mM of coagulant dosage. At 30 {+-} 2 C of tire recycling effluents, the combination effect was clearly shown in the removal of COD{sub Cr} over a wider range of pH. The reaction mechanisms of AlSi-1 and PASi-1 were also schematically studied. (orig.)

  8. Treatment of water turbidity and bacteria by using a coagulant extracted from Plantago ovata

    Directory of Open Access Journals (Sweden)

    Bahman Ramavandi

    2014-08-01

    Full Text Available A biocoagulant was successfully extracted from Plantago ovata by using an FeCl3-induced crude extract (FCE. The potential of FCE to act as a natural coagulant was tested for clarification using the turbid water of a river. Experimental tests were performed to evaluate the effects of turbidity concentration, coagulant quantity, water pH, and humic acid concentration on the coagulation of water turbidity by FCE. The maximum turbidity removal was occurred at water pH<8. At the optimum dosage of FCE, only 0.8 mg/L of dissolved organic carbon was released to the treated water. An increase in the humic acid led to the promotion of the water turbidity removal. Results demonstrated that the FCE removed more than 95.6% of all initial turbidity concentrations (50–300 NTU. High bacteriological quality was achieved in the treated water. FCE as an eco-friendly biocoagulant was revealed to be a very efficient coagulant for removing turbidity from waters.

  9. Trauma and Coagulation

    Directory of Open Access Journals (Sweden)

    Murat Yılmaz

    2011-08-01

    Full Text Available Bleeding and coagulation disorders related to trauma are pathological processes which are frequently seen and increase mortality. For the purpose, trauma patients should be protected from hypoperfusion, hypothermia, acidosis and hemodilution which may aggravate the increase in physiological responses to trauma as anticoagulation and fibrinolysis. Performing damage control surgery and resuscitation and transfusion of adequate blood and blood products in terms of amount and content as stated in protocols may increase the rate of survival. Medical treatments augmenting fibrin formation (fibrinogen, desmopressin, factor VIIa or preventing fibrin degradation (tranexamic acid have been proposed in selected cases but the efficacy of these agents in trauma patients are not proven. (Journal of the Turkish Society Intensive Care 2011; 9:71-6

  10. Coagulation disorders in the patients with deep vein thrombosis of lower extremity

    Directory of Open Access Journals (Sweden)

    Milić Dragan J.

    2003-01-01

    Full Text Available PURPOSE Venous thromboembolism is a relevant social and health care problem for its high incidence, pulmonary embolism-related mortality and long-term sequelae which may be disabling (post-thrombotic syndrome and ulceration. PROCEDURES The aim of our work was to establish the presence of coagulation disorders (hypercoagulable states in the patients with deep vein thrombosis (DVT of the leg. Prospectively we have analyzed a group of 30 patients with echosono-graphicaly verified DVT of the leg who were admitted to the department of vascular surgery from August 1st 2000 to July 31st 2001.The following parameters were monitored: prothrombin time (PT partial thromboplastin time (PTT, fibrinogen (Fib, alpha 2 antiplasmin (A-2 AP, D-dimer (DD, antithrombin III (AT III and factor VII. FINDINGS Activation of the coagulation process was registered. The values of monitored coagulation parameters are shown in table 1. Plasma levels of monitored parameters in the patients with DVT of the leg were significantly higher than in the control subjects. CONCLUSION In patients with a DVT a hypercoagulable state is common finding. Some parameters of coagulation activity such as D-dimer might be of great interest in the diagnostic strategy of DVT.

  11. Upgrading secondary wastewater plant effluent by modified coagulation and flocculation, for water reuse in irrigation

    Directory of Open Access Journals (Sweden)

    Mohammad Taghi Ghaneian

    2017-09-01

    Full Text Available In this study, the feasibility of using coagulation, flocculation, and sedimentation (CF-S for advanced treatment of secondary effluent released from the Yazd Intermittent Cycle Extended Aeration System was investigated. Four coagulants including ferric chloride (FeCl3, polyaluminum chloride (PAC, ferrous sulfate (FeSo4, and potassium ferrate (K2FeSo4 along with Gflog C-150 as flocculant polymer were used. In this study, returned chemical sludge was considered as a modification. Preliminary CF-S processes showed that FeSO4 and K2FeO4 had low removal efficiencies. Thus, these two coagulants were abandoned and CF-S processes were continued only with PAC and FeCl3 coagulants which had higher efficiencies in the removal of biological oxygen demand (BOD5, chemical oxygen demand (COD, total suspended solids (TSS, and turbidity. Removal efficiency was higher when half of the chemical producing sludge was returned as compared with using both coagulants simultaneously along with 2 mg L−1 of C-150 as flocculant. In the optimum dosage, when half of PAC and FeCl3 sludge were returned, the volume of produced sludge was reduced by 40% and 28%, respectively, as compared without returned sludge. For the PAC coagulant in the optimum dosage with half of the sludge returned, all 2012 EPA standards of irrigation were met for both ‘processed and non-processed type’ agricultural crops.

  12. Measurement of the coagulation dynamics of bovine liver using the modified microscopic Beer-Lambert law.

    Science.gov (United States)

    Terenji, Albert; Willmann, Stefan; Osterholz, Jens; Hering, Peter; Schwarzmaier, Hans-Joachim

    2005-06-01

    During heating, the optical properties of biological tissues change with the coagulation state. In this study, we propose a technique, which uses these changes to monitor the coagulation process during laser-induced interstitial thermotherapy (LITT). Untreated and coagulated (water bath, temperatures between 35 degrees C and 90 degrees C for 20 minutes.) samples of bovine liver tissue were examined using a Nd:YAG (lambda = 1064 nm) frequency-domain reflectance spectrometer. We determined the time integrated intensities (I(DC)) and the phase shifts (Phi) of the photon density waves after migration through the tissue. From these measured quantities, the time of flight (TOF) of the photons and the absorption coefficients of the samples were derived using the modified microscopic Beer-Lambert law. The absorption coefficients of the liver samples decreased significantly with the temperature in the range between 50 degrees C and 70 degrees C. At the same time, the TOF of the investigated photos was found increased indicating an increased scattering. The coagulation dynamics could be well described using the Arrhenius formalism with the activation energy of 106 kJ/mol and the frequency factor of 1.59 x 10(13)/second. Frequency-domain reflectance spectroscopy in combination with the modified microscopic Beer-Lambert (MBL) is suitable to measure heat induced changes in the absorption and scattering properties of bovine liver in vitro. The technique may be used to monitor the coagulation dynamics during local thermo-coagulation in vivo. Copyright 2005 Wiley-Liss, Inc.

  13. The immediate and late effects of thyroid hormone (triiodothyronine) on murine coagulation gene transcription

    NARCIS (Netherlands)

    Salloum-Asfar, Salam; Boelen, Anita; Reitsma, Pieter H.; van Vlijmen, Bart J. M.

    2015-01-01

    Thyroid dysfunction is associated with changes in coagulation. The aim of our study was to gain more insight into the role of thyroid hormone in coagulation control. C57Black/6J mice received a low-iodine diet and drinking water supplemented with perchlorate to suppress endogenous triiodothyronine

  14. Measurement of blood coagulation with considering RBC aggregation through a microchip-based light transmission aggregometer.

    Science.gov (United States)

    Lim, Hyunjung; Nam, Jeonghun; Xue, Shubin; Shin, Sehyun

    2011-01-01

    Even though blood coagulation can be tested by various methods and techniques, the effect of RBC aggregation on blood coagulation is not fully understood. The present study monitored clot formation in a microchip-based light transmission aggregometer. Citrated blood samples with and without the addition of calcium ion solution were initially disaggregated by rotating a stirrer in the microchip. After abrupt stop of the rotating stirrer, the transmitted light intensity over time was recorded. The syllectogram (light intensity vs. time graph) manifested a rapid increase that is associated with RBC aggregation followed by a decrease that is associated with blood coagulation. The time to reach the peak point was used as a new index of coagulation time (CT) and ranged from 200 to 500 seconds in the present measurements. The CT was inversely proportional to the concentration of fibrinogen, which enhances RBC aggregation. In addition, the CT was inversely proportional to the hematocrit, which is similar to the case of the prothrombin time (PT), as measured by a commercial coagulometer. Thus, we carefully concluded that RBC aggregation should be considered in tests of blood coagulation.

  15. Effect of Chitosan as a Coagulant Aid Combined With Poly Aluminum Chloride Removing of Turbidity From Drinking Water

    Directory of Open Access Journals (Sweden)

    Abdolmotaleb Seid Mohammadi

    2014-12-01

    Full Text Available Chitosan, a biodegradable polymer, is used as an eco-friendly coagulant in a wide variety of applications in water and wastewater treatment. The present study aimed to investigate the effect of chitosan as a coagulant aid combined with poly aluminum chloride (PAC to enhance coagulating efficiency for bentonite suspensions. A conventional jar test apparatus was used for the tests. The effect of various operational parameters, such as initial pH of the solution (5-9.5, dosage of chitosan (0.5-3.5 mg/L, dosage of PAC (5-35 mg/L and initial turbidity (50-200 NTU were investigated. The maximum turbidity removal rates were obtained as pH 8.5 for PAC and pH 7.5 for combined PAC and chitosan (CPC. The coagulating efficiency of bentonite using PAC and CPA was found to decrease with an increase in the pH value of the solutions. The maximum turbidity removal rate was achieved in coagulating by PAC (30 mg/L alone, and PAC (20 mg/L combined with chitosan (2.5 mg/L as coagulant aid with the removal rate of 87% and 96%, respectively. The optimum dosage of chitosan required to obtain the highest removal rate was 2.5 mg/L. Hence, using chitosan as a coagulant aid can not only reduce the required amount of coagulant (35% but can also enhance the removal turbidity efficiency.

  16. Synthesis of Phosphatidylserine and Its Stereoisomers: Their Role in Activation of Blood Coagulation.

    Science.gov (United States)

    Mallik, Suman; Prasad, Ramesh; Bhattacharya, Anindita; Sen, Prosenjit

    2018-05-10

    Natural phosphatidylserine (PS), which contains two chiral centers, enhances blood coagulation. However, the process by which PS enhanced blood coagulation is not completely understood. An efficient and flexible synthetic route has been developed to synthesize all of the possible stereoisomers of PS. In this study, we examined the role of PS chiral centers in modulating the activity of the tissue factor (TF)-factor VIIa coagulation initiation complex. Full length TF was relipidated with phosphatidylcholine, and the synthesized PS isomers were individually used to estimate the procoagulant activity of the TF-FVIIa complex via a FXa generation assay. The results revealed that the initiation complex activity was stereoselective and had increased sensitivity to the configuration of the PS glycerol backbone due to optimal protein-lipid interactions.

  17. optimization of coagulation-flocculation process for colour removal

    African Journals Online (AJOL)

    user

    2DEPARTMENT OF CHEMICAL ENGINEERING, NNAMDI AZIKIWE UNIVERSITY, AWKA, ANAMBRA STATE. ... The ability of organic polymer rich coagulants for colour removal from acid dye was studied. ... Response surface methodology (RSM) using face-centered ...... successfully applied for modeling and optimizing the.

  18. Population pharmacokinetics of recombinant coagulation factor VIII-SingleChain in patients with severe hemophilia A.

    Science.gov (United States)

    Zhang, Y; Roberts, J; Tortorici, M; Veldman, A; St Ledger, K; Feussner, A; Sidhu, J

    2017-06-01

    Essentials rVIII-SingleChain is a unique recombinant factor VIII (FVIII) molecule. A population pharmacokinetic model was based on FVIII activity of severe hemophilia A patients. The model was used to simulate factor VIII activity-time profiles for various dosing scenarios. The model supports prolonged dosing of rVIII-SingleChain with intervals of up to twice per week. Background Single-chain recombinant coagulation factor VIII (rVIII-SingleChain) is a unique recombinant coagulation factor VIII molecule. Objectives To: (i) characterize the population pharmacokinetics (PK) of rVIII-SingleChain in patients with severe hemophilia A; (ii) identify correlates of variability in rVIII-SingleChain PK; and (iii) simulate various dosing scenarios of rVIII-SingleChain. Patients/Methods A population PK model was developed, based on FVIII activity levels of 130 patients with severe hemophilia A (n = 91 for ≥ 12-65 years; n = 39 for  85% and > 93% of patients were predicted to maintain FVIII activity level above 1 IU dL -1 , at all times with three-times-weekly dosing (given on days 0, 2, and 4.5) at the lowest (20 IU kg -1 ) and highest (50 IU kg -1 ) doses, respectively. For twice weekly dosing (days 0 and 3.5) of 50 IU kg -1 rVIII-SingleChain, 62-80% of patients across all ages were predicted to maintain a FVIII activity level above 1 IU dL -1 at day 7. Conclusions The population PK model adequately characterized rVIII-SingleChain PK, and the model can be utilized to simulate FVIII activity-time profiles for various dosing scenarios. © 2017 The Authors. Journal of Thrombosis and Haemostasis published by Wiley Periodicals, Inc. on behalf of International Society on Thrombosis and Haemostasis.

  19. Infrared coagulation versus rubber band ligation in early stage hemorrhoids

    Directory of Open Access Journals (Sweden)

    P.J. Gupta

    2003-10-01

    Full Text Available The ideal therapy for early stages of hemorrhoids is always debated. Some are more effective but are more painful, others are less painful but their efficacy is also lower. Thus, comfort or efficacy is a major concern. In the present randomized study, a comparison is made between infrared coagulation and rubber band ligation in terms of effectiveness and discomfort. One hundred patients with second degree bleeding piles were randomized prospectively to either rubber band ligation (N = 54 or infrared coagulation (N = 46. Parameters measured included postoperative discomfort and pain, time to return to work, relief in incidence of bleeding, and recurrence rate. The mean age was 38 years (range 19-68 years. The mean duration of disease was 17.5 months (range 12 to 34 months. The number of male patients was double that of females. Postoperative pain during the first week was more intense in the band ligation group (2-5 vs 0-3 on a visual analogue scale. Post-defecation pain was more intense with band ligation and so was rectal tenesmus (P = 0.0059. The patients in the infrared coagulation group resumed their duties earlier (2 vs 4 days, P = 0.03, but also had a higher recurrence or failure rate (P = 0.03. Thus, we conclude that band ligation, although more effective in controlling symptoms and obliterating hemorrhoids, is associated with more pain and discomfort to the patient. As infrared coagulation can be conveniently repeated in case of recurrence, it could be considered to be a suitable alternative office procedure for the treatment of early stage hemorrhoids.

  20. Evaluation of Disseminated Intravascular Coagulation in the Craniocerebral Traumas

    Directory of Open Access Journals (Sweden)

    Faruk Altinel

    2014-06-01

    Full Text Available Traumatic injury is one of the most important cause of disseminated intravascular coagulation (DIC. It occurs because of blood loss and hemodilution due to fluid resuscitation. The incidence of trauma associated DIC is mainly higher in the craniocerebral traumas. Even though craniocerebral trauma related DIC is well defined, the pathophysiology has been poorly characterized in the literature. Due to the fact that brain tissue is highly significant for procoagulant molecules, craniocerebral traumas are closely related to DIC. In the current study, 30 patients admitted to emergency room have been considered on the first and fifth day of admission to the hospital for the coagulation tests to evaluate DIC in both two groups. [Cukurova Med J 2014; 39(3.000: 488-495

  1. Networks of enzymatically oxidized membrane lipids support calcium-dependent coagulation factor binding to maintain hemostasis

    NARCIS (Netherlands)

    Lauder, S.N.; Allen-Redpath, K.; Slatter, D.A.; Aldrovandi, M.; O'Connor, A.; Farewell, D.; Percy, C.L.; Molhoek, J.E.; Rannikko, S.; Tyrrell, V.J.; Ferla, S.; Milne, G.L.; Poole, A.W.; Thomas, C.P.; Obaji, S.; Taylor, P.R.; Jones, S.A.; Groot, P.G. de; Urbanus, R.T.; Horkko, S.; Uderhardt, S.; Ackermann, J.; Jenkins, P.V.; Brancale, A.; Kronke, G.; Collins, P.W.; O'Donnell, V.B.

    2017-01-01

    Blood coagulation functions as part of the innate immune system by preventing bacterial invasion, and it is critical to stopping blood loss (hemostasis). Coagulation involves the external membrane surface of activated platelets and leukocytes. Using lipidomic, genetic, biochemical, and mathematical

  2. Therapeutic intervention in disseminated intravascular coagulation: have we made any progress in the last millennium?

    NARCIS (Netherlands)

    Levi, Marcel; de Jonge, Evert; van der Poll, Tom

    2002-01-01

    Disseminated intravascular coagulation (DIC) is a syndrome characterized by systemic intravascular activation of coagulation, leading to widespread deposition of fibrin in the circulation. Recent knowledge on important pathogenetic mechanisms that may lead to DIC has resulted in novel preventive and

  3. Microwave coagulation therapy and drug injection to treat splenic injury.

    Science.gov (United States)

    Zhang, Guoming; Sun, Yuanyuan; Yu, Jie; Dong, Lei; Mu, Nannan; Liu, Xiaohong; Liu, Lanfen; Zhang, Yan; Wang, Xiaofei; Liang, Ping

    2014-01-01

    The present study compares the efficacy of 915- and 2450-MHz contrast-enhanced ultrasound (CEUS)-guided percutaneous microwave coagulation with that of CEUS-guided thrombin injection for the treatment of trauma-induced spleen hemorrhage. In a canine splenic artery hemorrhage model with two levels of arterial diameter (A, microwaves and drug injection. Therapy efficacy was measured by comparing bleeding rate, hemostatic time, bleeding index, bleeding volume, and pathology. The most efficient technique was CEUS-guided 915-MHz percutaneous microwave coagulation therapy in terms of action time and total blood loss. The success rate of the 915-MHz microwave group was higher than that of the 2450-MHz microwave and the drug injection groups (except A level, P microwave group than those in the 2450-MHz microwave and drug injection groups (P microwave group, but pathologic changes of light injury could be seen in the other groups. The present study provides evidence that microwave coagulation therapy is more efficient than thrombin injection for the treatment of splenic hemorrhage. Furthermore, treatment with 915-MHz microwaves stops bleeding more rapidly and generates a wider cauterization zone than does treatment with 2450-MHz microwaves. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Characterisation of coal washery effluent and optimisation of coagulation behaviour of Moringa oleifera seed as a coagulant.

    Science.gov (United States)

    Kapse, Gaurav; Patoliya, Pruthvi; Samadder, S R

    2017-03-01

    The huge quantity of effluent generated in coal washing processes contains large amount of suspended and dissolved solids, clay minerals, coal fines and other impurities associated with raw coal. The present system of recirculation of the effluent is found to be ineffective in removing colloidal fines, which is the major part of the impurities present in washery effluent. Hence, there is a need for the assessment of a better technique for an efficient removal of these impurities. This study deals with detailed characterisation of coal washery effluent and fine particles present in it. For efficient removal of impurities, the suitability of biocoag-flocculation process using Moringa oleifera seed biomass as a natural coagulant was examined. Various doses of M. oleifera ranging from 0.2 to 3 mL/L were used in order to determine the optimal conditions. The impact of the variations in pH of the effluent (2-10), contact time (5-30 min), settlement time (5-50 min), temperature (10-50 °C) and the effluent dilution (1:0-1:5) was also assessed to optimise the treatment process. Post treatment analysis was carried out for determination of the different parameters such as pH, conductivity, turbidity, solids and settling velocity. Excellent reduction in turbidity (97.42%) and suspended solids (97.78%) was observed at an optimum dose of M. oleifera seed coagulant of 0.8 mL/L with an optimum contact time of 15 and at 20 min of settling time. In comparison with very few past studies of M. oleifera in the treatment of coal washery effluent with high dose and inadequate removal, this study stands to be a major highlight with low dose and high removal of the impurities. M. oleifera coagulant is considered to be an environment-friendly material, therefore, its application is recommended for simple and efficient treatment of coal washery effluent.

  5. Reduction of Acid-Fast and Non-Acid-Fast Bacteria by Point of Use Coagulation-Flocculation-Disinfection

    Directory of Open Access Journals (Sweden)

    Lisa M. Casanova

    2015-11-01

    Full Text Available Point of use (POU household water treatment is increasingly being adopted as a solution for access to safe water. Non-tuberculous Mycobacteria (NTM are found in water, but there is little research on whether NTM survive POU treatment. Mycobacteria may be removed by multi-barrier treatment systems that combine processes such as coagulation, settling and disinfection. This work evaluated removal of a non-tuberculous Mycobacterium (Mycobaterium terrae and a Gram-negative non-acid-fast environmental bacterium (Aeromonas hydrophila by combined coagulation-flocculation disinfection POU treatment. Aeromonas hydrophila showed 7.7 log10 reduction in demand free buffer, 6.8 log10 in natural surface water, and 4 log10 reduction in fecally contaminated surface water. Turbidity after treatment was <1 NTU. There was almost no reduction in levels of viable M. terrae by coagulant-flocculant-disinfectant in natural water after 30 minutes. The lack of Mycobacteria reduction was similar for both combined coagulant-flocculant-disinfectant and hypochlorite alone. A POU coagulant-flocculant-disinfectant treatment effectively reduced A. hydrophila from natural surface waters but not Mycobacteria. These results reinforce previous findings that POU coagulation-flocculation-disinfection is effective against gram-negative enteric bacteria. POU treatment and safe storage interventions may need to take into account risks from viable NTM in treated stored water and consider alternative treatment processes to achieve NTM reductions.

  6. Coagulation changes following traumatic brain injury and shock

    DEFF Research Database (Denmark)

    Sillesen, Martin

    2014-01-01

    In these studies, we have shown that coagulation and innate immunity pathways respond to trauma within minutes. Furthermore, the appearance of dysfunction of platelets as well as activation of the endothelium is rapidly manifested. Interestingly, many of these changes were attenuated by treatment...

  7. Coagulant property of an indigenous seed: home water treatment in Tamil Nadu

    Energy Technology Data Exchange (ETDEWEB)

    Abel, R; Kawata, K; el-Sebaie, O D

    1985-01-01

    Use of some vegetable substances as coagulant has been recorded in historical literature. A seed from the tree known as tettan cottai is used today in South Indian villages to purify water. The scrapings of the seed were shown in laboratory experiments to have coagulant properties. It would be extremely valuable to have additional measurements made in South India, where the practice is employed in removal of turbidity, and also to have evidence of the extent of removal microorganisms.

  8. Integration of coagulation and adsorption for removal of N-nitrosodimethylamine (NDMA) precursors from biologically treated municipal wastewater.

    Science.gov (United States)

    Wang, Miaomiao; Meng, Yingjie; Ma, Defang; Wang, Yan; Li, Fengli; Xu, Xing; Xia, Chufan; Gao, Baoyu

    2017-05-01

    This study investigated the N-nitrosodimethylamine (NDMA) formation potential of various dissolved organic matter (DOM) fractions in biologically treated municipal wastewater by UF fractionation, XAD-8 resin adsorption isolation, and excitation and emission matrix (EEM) fluorescence spectroscopy. Removal of various NDMA precursor fractions was also analyzed to evaluate the efficiency of traditional water treatment processes (coagulation, adsorption, and coagulation-adsorption). Results showed that NDMA were mainly formed by low molecular weight (MW) fractions (NDMA formation potential (57%), followed by isolated adsorption treatment (50%) and isolated coagulation treatment (28%). The powdered activated carbon (PAC) adsorption process could reduce the high MW precursors (>30 kDa) by 48%, which was higher than other treatments. In contrast, the highest uptake (66%) of low MW precursors (<30 kDa) was achieved by the coagulation-adsorption process. All treatments preferentially removed the hydrophobic acids (HoA) fraction compared to other fractions. Coagulation could remove more fulvic acid-like substances and adsorption could remove more microbial by-products and aromatic proteins.

  9. A comparison of the determination of the rennet coagulation properties of bovine milk

    Directory of Open Access Journals (Sweden)

    Roman Pytel

    2016-07-01

    Full Text Available The aim of the work was compared of two different methods (the visual method and the nephelo turbidimetry method for determination of rennet coagulation time. It was observed the effect of heat treatment of milk; types of rennet and addition of different amount of CaCl2 into the pasteurized milk. It was used two different chymosin rennet. For the visual method was milk sample (100 mL equilibrated at 35 °C, 1 mL of rennet was added into milk and was measured the time required for the first visible flakes (visual method. For the determination rennet coagulation time by nephelo-turbidimetry was removed part of milk with rennet and placed into nephelo-turbidimetry. Milk had a titratable acidity in the range from 6.5 to 7.0 °SH, average pH of milk was 6.68. Dry matter content was in range from 12.351 to 13.142%. The average content of protein by Kjeldahl was 3.14%, fat by Gerber 4.34%, lactose by polarimetry 4.68% and calcium content 1.1%. The pasteurized milk had the worst rennet coagulation time about 32 s compared to the raw milk. The difference coagulation time between milk with addition of 20 µL CaCl2 and 40 µL CaCl2 was in range 21 s to 26 s by visual method. The difference coagulation time between milk with addition of 20 µL CaCl2 and 40 µL CaCl2 was 15 s by nephelo-turbidimetry method. There occurred statistically non-significant differences in most of the measurements, comparing the visual and the nephelo-turbidimetric method. The heat treatment, addition of CaCl2 and using of different rennet had an influence on the curd category. It was obtained, that using nephelo-turbidimetry shown objective results for measuring the rennet coagulation time contrary the subjective visual method. Further, the results obtained by nephelo-turbidimetry are accurate and determined with the lower variation.

  10. Untangling the complexity of blood coagulation network: use of computational modelling in pharmacology and diagnostics.

    Science.gov (United States)

    Shibeko, Alexey M; Panteleev, Mikhail A

    2016-05-01

    Blood coagulation is a complex biochemical network that plays critical roles in haemostasis (a physiological process that stops bleeding on injury) and thrombosis (pathological vessel occlusion). Both up- and down-regulation of coagulation remain a major challenge for modern medicine, with the ultimate goal to correct haemostasis without causing thrombosis and vice versa. Mathematical/computational modelling is potentially an important tool for understanding blood coagulation disorders and their treatment. It can save a huge amount of time and resources, and provide a valuable alternative or supplement when clinical studies are limited, or not ethical, or technically impossible. This article reviews contemporary state of the art in the modelling of blood coagulation for practical purposes: to reveal the molecular basis of a disease, to understand mechanisms of drug action, to predict pharmacodynamics and drug-drug interactions, to suggest potential drug targets or to improve quality of diagnostics. Different model types and designs used for this are discussed. Functional mechanisms of procoagulant bypassing agents and investigations of coagulation inhibitors were the two particularly popular applications of computational modelling that gave non-trivial results. Yet, like any other tool, modelling has its limitations, mainly determined by insufficient knowledge of the system, uncertainty and unreliability of complex models. We show how to some extent this can be overcome and discuss what can be expected from the mathematical modelling of coagulation in not-so-far future. © The Author 2015. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  11. Evaluating the Efficiency of Tragacanth Coagulant Aid in Removing Colloidal Materials and Suspended Solids Creating Turbidity from Karun River Water

    OpenAIRE

    Majid Farhadi; Afshin Takdastan; Roghayeh Baghbany

    2016-01-01

    Introduction: Colloidal materials and suspended solids cause turbidity in water. To remove turbidity, clarification method is used that includes processes of coagulation, flocculation, and sedimentation. Due to the long duration of coagulation process, coagulant aids are applied. Despite the favorable efficiency of synthetic polyelectrolytes as a coagulant aid, due to their harmful effects on human health, in this process, natural organic polymers are used instead. Materials and Methods: I...

  12. coagulation factors level in fresh frozen plasma in rwanda

    African Journals Online (AJOL)

    2014-02-02

    Feb 2, 2014 ... Setting: Jomo Kenyatta University of Agriculture and Technology in ... a major role in blood coagulation process. ... storage conditions and quality control prior to clinical ... instrumentation Laboratory Company USA made in.

  13. Charging and coagulation of water aerosols with negligible addition of high-radioactive droplets

    International Nuclear Information System (INIS)

    Vasil'eva, N.L.; Sedova, G.L.; Chernyj, L.T.

    1994-01-01

    The mechanics of electrocoagulation of water aerosols with negligible admixture of high-radioactive droplets is considered. A corresponding mathematical model has been worked out which describes the processes of ionization, electrification and coagulation of radioactive aerosols. Numerical studies are carried out for a series of typical aerosols on the time dependence of ion concentrations, charge and pure droplet concentrations, as well as the charge and radius of radioactive droplets. It is shown that coagulation can give rise to the growth of droplet radius from 5-10 μm up to 30-40 μm for a 10 4 s period f time, and therefore it can play a considerable role in the development of aerosols with droplet radius up to 20 μm when gravitational coagulation is insignificant

  14. [Variation of water DOC during the process of pre-pressure and coagulation sedimentation treatment].

    Science.gov (United States)

    Chen, Wen-Jing; Cong, Hai-Bing; Xu, Ya-Jun; Wang, Wei; Jiang, Xin-Yue; Liu, Yu-Jiao

    2014-07-01

    The aim of the study was to explore whether the pre-pressure and coagulation sedimentation process would result in algal cell disruption, leading to increased dissolved organic carbon (DOC) in water, based on which, the pressure application mode would be optimized and safe and efficient pre-pressure algae removal process would be obtained. The changes in DOC during the process of pre-pressure and preoxidation treatment, the distribution of molecular weight in water as well as the removal efficiency of algae, turbidity and DOC after coagulation and sedimentation were investigated. The results showed that the DOC in water did not increase but decreased, and the molecular weight decreased after treated with 0.5-0.8 MPa pressure. While KMnO4 and NaClO pre-oxidation both increased the DOC, in the meanwhile, the distribution of molecular weight showed no obvious change. After the pre-pressure coagulation and sedimentation process, the removal rate of algae was 96.23% and that of DOC was 29. 11%, which was by 10% - 30% higher than the rate of pre-oxidation coagulation and sedimentation process.

  15. Laser tissue coagulation and concurrent optical coherence tomography through a double-clad fiber coupler

    Science.gov (United States)

    Beaudette, Kathy; Baac, Hyoung Won; Madore, Wendy-Julie; Villiger, Martin; Godbout, Nicolas; Bouma, Brett E.; Boudoux, Caroline

    2015-01-01

    Double-clad fiber (DCF) is herein used in conjunction with a double-clad fiber coupler (DCFC) to enable simultaneous and co-registered optical coherence tomography (OCT) and laser tissue coagulation. The DCF allows a single channel fiber-optic probe to be shared: i.e. the core propagating the OCT signal while the inner cladding delivers the coagulation laser light. We herein present a novel DCFC designed and built to combine both signals within a DCF (>90% of single-mode transmission; >65% multimode coupling). Potential OCT imaging degradation mechanisms are also investigated and solutions to mitigate them are presented. The combined DCFC-based system was used to induce coagulation of an ex vivo swine esophagus allowing a real-time assessment of thermal dynamic processes. We therefore demonstrate a DCFC-based system combining OCT imaging with laser coagulation through a single fiber, thus enabling both modalities to be performed simultaneously and in a co-registered manner. Such a system enables endoscopic image-guided laser marking of superficial epithelial tissues or laser thermal therapy of epithelial lesions in pathologies such as Barrett’s esophagus. PMID:25909013

  16. Evolution behavior of catalytically activated replication—decline in a coagulation process

    International Nuclear Information System (INIS)

    Gao Yan; Wang Hai-Feng; Zhang Ji-Dong; Yang Xia; Sun Mao-Zhu; Lin Zhen-Quan

    2013-01-01

    We propose a catalytically activated replication—decline model of three species, in which two aggregates of the same species can coagulate themselves, an A aggregate of any size can replicate itself with the help of B aggregates, and the decline of A aggregate occurs under the catalysis of C aggregates. By means of mean-field rate equations, we derive the asymptotic solutions of the aggregate size distribution a k (t) of species A, which is found to depend strongly on the competition among three mechanisms: the self-coagulation of species A, the replication of species A catalyzed by species B, and the decline of species A catalyzed by species C. When the self-coagulation of species A dominates the system, the aggregate size distribution a k (t) satisfies the conventional scaling form. When the catalyzed replication process dominates the system, a k (t) takes the generalized scaling form. When the catalyzed decline process dominates the system, a k (t) approaches the modified scaling form. (condensed matter: structural, mechanical, and thermal properties)

  17. Use of electrocautery for coagulation and wound complications in Caesarean sections.

    Science.gov (United States)

    Moreira, Cristiane M; Amaral, Eliana

    2014-01-01

    To evaluate the safety of electrocautery for coagulation during Caesarean sections. A randomized, controlled, clinical pilot study was performed at a university maternity hospital. After admission for delivery and decision to perform a C-section, volunteers were randomized to either the intervention group (use of electrocautery for coagulation) or nonintervention group. The women were examined at the time of postpartum discharge (day 3), at days 7 to 10, and again at days 30 to 40 for signs of infection, hematoma, seroma, or dehiscence. Data were analyzed using an intention-to-treat analysis, and risk ratios were calculated. No significant differences were found between the two groups. Only 2.8% of patients in the intervention group developed surgical wound complications during hospitalization. However, 7 to 10 days following discharge, these rates reached 23.0% and 15.4% in the intervention and nonintervention groups, respectively (RR = 1.50, 95% CI = 0.84-2.60). Further studies should confirm whether the use of electrocautery for coagulation does not increase the risk of surgical wound complications in patients undergoing Caesarean sections.

  18. Aversion substance(s) of the rat coagulating glands

    Science.gov (United States)

    Gawienowski, Anthony M.; Berry, Iver J.; Kennelly, James J.

    1982-01-01

    The aversive substance(s) present in adult male urine were not found in castrate rat urine. Removal of the coagulating glands also resulted in a loss of the aversion compounds. The aversion substances were restored to the urine after androgen treatment of the castrate rats.

  19. Harvesting Microalgal Biomass grown in Anaerobic Sewage Treatment Effluent by the Coagulation-Flocculation Method: Effect of pH

    Directory of Open Access Journals (Sweden)

    Servio Tulio Cassini

    2017-03-01

    Full Text Available ABSTRACT Harvesting is a critical step in microalgal biomass production process for many reasons. Among the existing techniques available for harvesting and dewatering microalgal biomass, recovery from aqueous medium by coagulation-flocculation has been the most economically viable process, althoughit is highly dependent on pH. This study aims to assess alternative coagulants compared to the standard coagulant aluminum sulfate for microalgal biomass recovery from anaerobic effluent of domestic sewage treatment. The effluent quality was also analyzed after biomass recovery. Coagulants represented by modified tannin, cationic starch and aluminum sulfate recovered more than 90% of algae biomass, at concentrations greater than 80 mg/L, in the pH range 7-10. Cationic starch promoted higher microalgal biomass recovery with a wider pH range. Powdered seeds of Moringa oleifera and Hibiscus esculentus(okra gum promoted biomass removal of 50%, only in the acidic range of pH. After sedimentation of the microalgal biomass, the effluents showed a removal of >80% for phosphorus and nitrogen values and >50% for BOD and COD when using aluminum sulfate, cationic starch and modified tannin as coagulants. Natural organic coagulants in a wide pH range can replace aluminum sulfate, a reference coagulant in microalgal biomass recovery, without decreasing microalgal biomass harvesting efficiency and the quality of the final effluent.

  20. Investigational drugs for coagulation disorders.

    Science.gov (United States)

    Mannucci, Pier Mannuccio; Mancuso, Maria Elisa

    2013-08-01

    The current standard treatment in persons with hemophilia (PWH) is prophylaxis, given intravenously twice or thrice weekly, which is associated with a non negligible burden on patients' quality of life. Therefore the main attempts aiming to improve the management of PWH are targeted towards the development of a new generation of coagulation factors endowed with properties facilitating prophylaxis and/or a better control of bleeding. This article summarizes the main results obtained so far in the development of new antihemophilic products, and emphasizes the formidable requirements imposed upon by regulatory agencies to get marketing authorization for new drugs, which make progress in this field difficult. Published literature on new molecules for replacement treatment in hemophilia A and B has been retrieved by using PubMed search and all ongoing clinical trials have been looked for online. New molecules are usually engineered to have a longer plasma half-life but also in some instances a higher potency. The prolongation of half-life may be obtained by using sustained release delivery vehicles, by chemical modification or by creating fusion proteins. Factors VIII, IX and VII have been variably modified in order to obtain improved coagulation products and results from Phase I/II studies are encouraging, particularly for factor IX. However, Phase III studies that should provide evidence on efficacy and effectiveness more cogent for clinical use are still ongoing and results are not yet available.

  1. Effects of argon plasma coagulation on human stomach tissue: An ex vivo study.

    Science.gov (United States)

    Gong, Eun Jeong; Ahn, Ji Yong; Jung, Hwoon-Yong; Park, Young Soo; Na, Hee Kyong; Jung, Kee Wook; Kim, Do Hoon; Lee, Jeong Hoon; Choi, Kee Don; Song, Ho June; Lee, Gin Hyug; Kim, Jin-Ho

    2017-05-01

    Argon plasma coagulation (APC) is a safe alternative treatment for gastrointestinal neoplasms and precancerous lesions. However, the extent of thermal damage after APC is difficult to predict. We investigated the effects of APC on human stomach tissue. Argon plasma coagulation was performed on 10 freshly resected human stomachs that were obtained after total gastrectomy. The effects on tissue were compared across power settings (40, 60, and 80 W), durations (5, 10, 15, 20, and 25 s), and between injection (submucosal injection of normal saline) and control (without injection) groups. Success was defined as complete mucosal necrosis without damaging the muscularis propria. Without submucosal injection, the incidence of damaging the muscularis propria increased as the power and duration increased. Tissue damage in the injection group was mostly confined to the submucosa, even when using the high-power setting. In the injection group, ablations at 40 W for 20 s, 60 W for 15 s, and 80 W for 15 or 20 s produced success rates ≥80%. In the control group, ablations at 60 W for 10 s, and 80 W for 5, or 10 s produced success rates ≥80%. The optimal energy levels to achieve complete mucosal and submucosal necrosis without damaging the muscularis propria were 800-1600 and 600-800 J in the injection and control groups, respectively. Application of APC produces good results with a low risk of perforation. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  2. Impact of Rodenticides on the Coagulation Properties of Milk

    Directory of Open Access Journals (Sweden)

    Salam A. Ibrahim

    2018-04-01

    Full Text Available In this study, we investigated the impact of the rodenticides (strychnine, bromadiolone, and brodifacoum on milk pH, rennet coagulation time (RCT, and coagulum strength. Sub-lethal amounts of strychnine and bromadiolone produced an unnaturally large change in milk pH, compared to brodifacoum and brodifacoum on milk coagulation properties. All three studied rodenticides significantly affected RCT and coagulum strength. The presence of sub-lethal amounts of each individual rodenticide increased RCT by an overall mean of 17% (p < 0.001. Rodenticide contamination decreased coagulum strength by an overall mean of 26% (p < 0.05. Our results suggest that such changes could be noticeable at the farm, thus, potentially averting the mixture of contaminated milk with the tanker supply, and preventing downstream distribution to consumers.

  3. Retinal venous thrombosis in a young patient with coagulation factor XII deficiency.

    Science.gov (United States)

    Borrego-Sanz, L; Santos-Bueso, E; Sáenz-Francés, F; Martínez-de-la-Casa, J M; García-Feijoo, J; Gegúndez-Fernández, J A; García-Sánchez, J

    2014-08-01

    A 35-year-old woman, with no relevant medical history, was referred for sudden vision loss in the left eye. Ophthalmological examination showed best corrected visual acuity of 1.0 in the right eye and 0.3 in left eye, with normal anterior pole and intraocular pressure. Fundus examination of the left eye revealed a venous thrombosis in the superior temporal branch, with dilated and tortuous retinal veins. The patient was referred to the hematology unit for thrombophilia study, and was diagnosed with a coagulation XII or Hageman factor deficiency. The development of retinal vessel occlusions, in patients under 50 years of age, is frequently associated with thrombophilia or hypercoagulability disorders. Factor XII deficiency is a rare condition, and its presence could contribute to a higher risk of thromboembolic events. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  4. Identification of QTL on chromosome 18 associated with non-coagulating milk in Swedish Red cows

    NARCIS (Netherlands)

    Duchemin, Sandrine I.; Glantz, Maria; Koning, De Dirk Jan; Paulsson, Marie; Fikse, Willem F.

    2016-01-01

    Non-coagulating (NC) milk, defined as milk not coagulating within 40 min after rennet-addition, can have a negative influence on cheese production. Its prevalence is estimated at 18% in the Swedish Red (SR) cow population. Our study aimed at identifying genomic regions and causal variants

  5. Should anti-inhibitor coagulant complex and tranexamic acid be used concomitantly?

    Science.gov (United States)

    Valentino, L A; Holme, P A

    2015-11-01

    Inhibitor development in haemophilia patients is challenging especially when undergoing surgical procedures. The development of an inhibitor precludes using factor VIII (FVIII) therapy thereby requiring a bypassing agent (BPA) for surgical bleeding prophylaxis if the FVIII inhibitor titre >5 BU. Concomitant use of anti-inhibitor coagulant complex (AICC) and tranexamic acid has been reported in the literature as a beneficial treatment for this population. Anti-inhibitor coagulant complex is known to cause an increase in thrombin generation and tranexamic acid inhibits fibrinolysis. Hence, the combined used of AICC and tranexamic acid has been limited due to safety concerns over possibilities of increased risk of thrombotic events and disseminated intravascular coagulation. However, the rationale for concomitant therapy is to obtain a potential synergistic effect and to increase clot stability. We conducted a literature review of past studies and individual case reports of concomitant use of AICC and tranexamic acid, which was extensively used during dental procedures. Evidence also exists for concomitant use of the combined therapy in orthopaedic procedures, control of gastrointestinal bleeding, epistaxis and cerebral haemorrhages. Some patients who received the combined therapy had failed monotherapy with a single BPA prior to combined therapy. There were no reports of thrombotic complications related to the concomitant therapy and haemostasis was achieved in all cases. Anti-inhibitor coagulant complex and tranexamic acid therapy was found to be safe, well-tolerated and effective therapy in haemophilia patients with inhibitors. Additional randomized controlled studies should be performed to confirm these findings. © 2015 John Wiley & Sons Ltd.

  6. Renin-aldosterone-sodium profiling in normal Filipinos. Pt. 1

    International Nuclear Information System (INIS)

    Guevara, R.; Torres, J. Jr.; Abundo, H.P.; Perez, A.P.; Ochoa, W.K.

    1981-01-01

    Plasma renin activity determination by radioimmunoassay is feasible, accurate, reproducible and reliable. This profiling technic is a very useful guide for more rational and precise treatment of the hypertensive state, but even when profiling cannot be done, statistical nomograms can be useful, just as well, as a guide in the treatment of hypertewnsion. (orig.) [de

  7. Short communication: Prediction of milk coagulation and acidity traits in Mediterranean buffalo milk using Fourier-transform mid-infrared spectroscopy.

    Science.gov (United States)

    Manuelian, C L; Visentin, G; Boselli, C; Giangolini, G; Cassandro, M; De Marchi, M

    2017-09-01

    Milk coagulation and acidity traits are important factors to inform the cheesemaking process. Those traits have been deeply studied in bovine milk, whereas scarce information is available for buffalo milk. However, the dairy industry is interested in a method to determine milk coagulation and acidity features quickly and in a cost-effective manner, which could be provided by Fourier-transform mid-infrared (FT-MIR) spectroscopy. The aim of this study was to evaluate the potential of FT-MIR to predict coagulation and acidity traits of Mediterranean buffalo milk. A total of 654 records from 36 herds located in central Italy with information on milk yield, somatic cell score, milk chemical composition, milk acidity [pH, titratable acidity (TA)], and milk coagulation properties (rennet coagulation time, curd firming time, and curd firmness) were available for statistical analysis. Reference measures of milk acidity and coagulation properties were matched with milk spectral information, and FT-MIR prediction models were built using partial least squares regression. The data set was divided into a calibration set (75%) and a validation set (25%). The capacity of FT-MIR spectroscopy to correctly classify milk samples based on their renneting ability was evaluated by a canonical discriminant analysis. Average values for milk coagulation traits were 13.32 min, 3.24 min, and 39.27 mm for rennet coagulation time, curd firming time, and curd firmness, respectively. Milk acidity traits averaged 6.66 (pH) and 7.22 Soxhlet-Henkel degrees/100 mL (TA). All milk coagulation and acidity traits, except for pH, had high variability (17 to 46%). Prediction models of coagulation traits were moderately to scarcely accurate, whereas the coefficients of determination of external validation were 0.76 and 0.66 for pH and TA, respectively. Canonical discriminant analysis indicated that information on milk coagulating ability is present in the MIR spectra, and the model correctly classified as

  8. Effects of oversulfated and fucosylated chondroitin sulfates on coagulation. Challenges for the study of anticoagulant polysaccharides.

    Science.gov (United States)

    Fonseca, Roberto J C; Oliveira, Stephan-Nicollas M C G; Pomin, Vitor H; Mecawi, André S; Araujo, Iracema G; Mourão, Paulo A S

    2010-05-01

    We report the effects of a chemically oversulfated chondroitin sulfate and a naturally fucosylated chondroitin sulfate on the coagulation system. The former has been recently identified as a contaminant of heparin preparations and the latter has been proposed as an alternative anticoagulant. The mechanism of action of these polymers on coagulation is complex and target different components of the coagulation system. They have serpin-independent anticoagulant activity, which preponderates in plasma. They also have serpin-dependent anticoagulant activity but differ significantly in the target coagulation protease and preferential serpin. Their anticoagulant effects differ even more markedly when tested as inhibitors of coagulation proteases using plasma as a source of serpins. It is possible that the difference is due to the high availability of fucosylated chondroitin sulfate whereas oversulfated chondroitin sulfate has strong unspecific binding to plasma protein and low availability for the binding to serpins. When tested using a venous thrombosis experimental model, oversulfated chondroitin sulfate is less potent as an antithrombotic agent than fucosylated chondroitin sulfate. These highly sulfated chondroitin sulfates activate factor XII in in vitro assays, based on kallikrein release. However, only fucosylated chondroitin sulfate induces hypotension when intravenously injected into rats. In conclusion, the complexity of the regulatory mechanisms involved in the action of highly sulfated polysaccharides in coagulation requires their analysis by a combination of in vitro and in vivo assays. Our results are relevant due to the urgent need for new anticoagulant drugs or alternative sources of heparin.

  9. [Haplotype Analysis of Coagulation Factor VII Gene in a Patient with Congenital Coagulation Factor VII Deficiency with Heterozygous p.Arg337Cys Mutation and o.Aro413Gin Polymorphism..

    Science.gov (United States)

    Suzuki, Keijiro; Yoshioka, Tomoko; Obara, Takehiro; Suwabe, Akira

    2016-05-01

    Congenital coagulation factor VII (FVII) deficiency is a rare hemorrhagic disease with an autosomal reces- sive inheritance pattern. We analyzed coagulation factor VII gene (F7) of a patient with FVII deficiency and used expression studies to investigate the effect of a missense mutation on FVII secretion. The proband, a 69-year-old Japanese woman, had a history of postpartum bleeding and excessive bleeding after dental extrac- tion. She was found to have mildly increased PT-INR (1.17) before an ophthalmic operation. FVII activity and antigen were reduced (29.0% and 32.8%). Suspecting that the proband was FVII deficient, we analyzed F7 of the patient. Sequence analysis revealed that the patient was heterozygous for a point mutation (p.Arg337Cys) in the catalytic domain and polymorphisms: the decanucleotide insertion at the promoter re- gion, dimorphism (c.525C >T) in exon 5, and p.Arg413Gln in exon 8. Haplotype analysis clarified that p.Arg337Cys was located on the p.Arg413 allele (Ml allele). The other allele had the p.Arg413Gln polymor- phism(M2 allele) which is known to produce less FVII. Expression studies revealed that p.Arg337Cys causes impairment of FVII secretion. Insufficient secretion of FVII arising from both the p.Arg337Cys/M1 allele and the p.Arg337/M2 allele might lower the FVII level of this patient(<50%). The FVII level in a heterozygous FVII deficient patient might be influenced by F7 polymorphisms on the normal allele. There- fore, genetic analyses are important for the diagnosis of heterozygous FVII deficiency.

  10. Uniqueness of Mass-Conserving Self-similar Solutions to Smoluchowski's Coagulation Equation with Inverse Power Law Kernels

    Science.gov (United States)

    Laurençot, Philippe

    2018-03-01

    Uniqueness of mass-conserving self-similar solutions to Smoluchowski's coagulation equation is shown when the coagulation kernel K is given by K(x,x_*)=2(x x_*)^{-α } , (x,x_*)\\in (0,∞)^2 , for some α >0.

  11. Optimization of coagulation-flocculation process for colour removal ...

    African Journals Online (AJOL)

    Response surface methodology (RSM) using face-centered central composite design (FCCD) was used to optimize the four variables. Increase in the colour removal efficiency was higher in acidic solution pH. Accurate control of coagulant dosages gave optimum destabilization of charged particles and re-stabilization ...

  12. Dragon Fruit Foliage Plant-Based Coagulant for Treatment of Concentrated Latex Effluent: Comparison of Treatment with Ferric Sulfate

    Directory of Open Access Journals (Sweden)

    Juferi Idris

    2013-01-01

    Full Text Available The effectiveness of dragon fruit foliage as a natural coagulant for treatment of concentrated latex effluent was investigated and compared with ferric sulfate, a chemical coagulant. Dragon fruit is a round and often red-colored fruit with scales-like texture and is native to south American countries which is also cultivated and heavily marketed in southeast Asian countries. Its foliage represents a part of its overall plant system. Latex effluent is one of the main byproduct from rubber processing factories in Malaysia. Three main parameters investigated were chemical oxygen demand (COD, suspended solids (SS, and turbidity of effluent. Coagulation experiments using jar test were performed with a flocculation system where the effects of latex effluent pH as well as coagulation dosage on coagulation effectiveness were examined. The highest recorded COD, SS, and turbidity removal percentages for foliage were observed for effluent pH 10 at 94.7, 88.9, and 99.7%, respectively. It is concluded that the foliage showed tremendous potential as a natural coagulant for water treatment purposes. The foliage could be used in the pretreatment stage of Malaysian latex effluent prior to secondary treatment.

  13. Reaction mechanisms and evaluation of effective process operation for catalytic oxidation and coagulation by ferrous solution and hydrogen peroxide

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.H.; Moon, H.J.; Kim, Y.M. [Dept. of Environmental Engineering, Sangmyung Univ., Cheonan (Korea); Bae, W.K. [Dept. of Civil and Environmental Engineering, Hanyang Univ., Ansan, Kyounggi (Korea)

    2003-07-01

    This research was carried out to evaluate the removal efficiencies of COD{sub cr} and colour for the dyeing wastewater by ferrous solution and the different dosage of H{sub 2}O{sub 2} in Fenton process. In the case of H{sub 2}O{sub 2} divided dosage, 7:3 was more effective than 3:7 to remove COD{sub cr} and colour. The results showed that COD was mainly removed by Fenton coagulation, where the ferric ions are formed in the initial step of Fenton reaction. On the other hand colour was removed by Fenton oxidation rather than Fenton coagulation. This paper also aims at pursuing to investigate the effective removal mechanisms using ferrous ion coagulation, ferric ion coagulation and Fenton oxidation process. The removal mechanism of COD{sub cr} and colour was mainly coagulation by ferrous ion, ferric ion and Fenton oxidation. The removal efficiencies were dependent on the ferric ion amount at the beginning of the reaction. However the final removal efficiency of COD and colour was in the order of Fenton oxidation, ferric ion coagulation and ferrous ion coagulation. The reason of the highest removal efficiency by Fenton oxidation can be explained by the chain reactions with ferrous solution, ferric ion and hydrogen peroxide. (orig.)

  14. Coagulation of dielectric dust grains due to variable asymmetric charging

    International Nuclear Information System (INIS)

    Manweiler, Jerry W.; Armstrong, Thomas P.; Cravens, Thomas E.

    1998-01-01

    Observational evidence of electrical forces acting significantly on small solids is present for both the modern solar system in Saturn's rings and the ancient solar system in chondritic meteorites. It is likely that grain-grain coagulation rates are affected by the distribution of charges on small grains. Plasma particle impacts and photoelectric effects can provide the charges. It appears that some charging is inevitable and that plasma grain interactions need to be evaluated to determine the size of the effect on coagulation rates. We apply the results of our previous charging work to models of the protoplanetary nebula. It is expected that the protoplanetary nebula is weakly ionized except in certain instances and locations such as: solar flares in the interior, ultraviolet radiation at the outer boundary, and during enhanced luminosity of the star. Since the grains we study are non-conducting and show strong dipole moments in flowing plasma, we modify the geometric cross sections to include the effects of flowing plasma on non-conducting grains with plasma mediated shielding. This paper provides results showing how plasma flow affects the processes involved in charging the grains--total charge and charge distribution. We calculate the modifications to the cross sections and subsequent changes in the coagulation rates

  15. Removal of arsenic from contaminated water using coagulation enhanced microfiltration

    International Nuclear Information System (INIS)

    Volchek, K.; Velicogna, D.; Dumouchel, A.; Wong, W.P.; Brown, C.E.

    2002-01-01

    Results of an innovative arsenic removal process were presented. The process is based on a combination of coagulation and microfiltration processes. Coagulation-Enhanced Microfiltration (CEMF) may eventually become a full-scale commercial technology. This study focused on the process with respect to groundwater treatment because of the importance of arsenic contamination in drinking water. Most experiments were bench-scale using tap water spiked with arsenic. Ferric chloride, which is commonly used in arsenic removal processes was also added. In addition, some tests were conducted on actual arsenic-contaminated water from the effluent treatment plant of a former mining site in Ontario. Results indicate a high arsenic removal efficiency in both spiked and actual water solutions. The microfiltration significantly reduced the level of arsenic in the treatment. This paper described the characteristics of membrane separation. It also presented information regarding chemically enhanced membrane filtration and coagulation-enhanced microfiltration. Bench-scale tests were conducted with both tubular membranes and with immersed capillary membranes. The effect of iron to arsenic ratios on the effectiveness of the system was also tested. It was recommended that future research should include a field study of the process on a pilot-scale to optimize process parameters and to accurately determine the cost of the process. 16 refs., 8 tabs., 9 figs

  16. Analysis of the Factors Associated with Abnormal Coagulation and Prognosis
in Patients with Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Yanhua LI

    2014-11-01

    Full Text Available Background and objective The activation of coagulation and fibrinolysis is frequently encountered among cancer patients. Such tumors are associated with high risk of invasion, metastases, and negative final outcomes. Non-small cell lung cancer (NSCLC accounts for approximately 80% to 85% of all lung malignancies. This study aims to investigate the prognostic value of blood coagulation tests for NSCLC and provide a reference to patients on the prevention and treatment of thrombophilia. Methods Data were collected from 604 cases of hospitalized patients with histologically confirmed NSCLC from January 2009 to December 2012 at the Fourth Hospital of Hebei Medical University. Data included the related indexes of coagulation function in patients before treatment [(i.e., prothrombin time (PT, prothrombin time activity (PTA, international normalized ratio (INR, activated partial thromboplastin time (APTT, fibrinogen (Fib, D-dimer, and platelet count], as well as sex, age, pathological type, TNM stage, and lymph node status. Fifty control subjects without cancer were included in the analysis. Statistical analysis was conducted by using SPSS 13.0 software. Results The plasma level of all coagulation tests including D-dimer, Fib, PT, APTT, INR, and platelet counts revealed statistically significant differences between the patient and control group (P<0.001 for all variables; P=0.001,5 and P=0.004,5 for Fib and platelet counts, respectively. The squamous subtype exhibited high plasma Fib levels (P<0.001 compared with adenocarcinoma cell lung cancer patients. Fib and PLT levels increased (P<0.001 and P=0.014, respectively, and aPTT decreased (P<0.001 in patients at stages III and IV compared with those in patients at stages I and II. aPTT decreased significantly (P<0.001, and Fib and D-dimer levels increased (P<0.001 and P=0.048, respectively in N1-3 patients with NSCLC compared with those of N0 patients. Prolonged PT and INR, high plasma Fib levels, and

  17. Coagulant recovery from water treatment plant sludge and reuse in post-treatment of UASB reactor effluent treating municipal wastewater.

    Science.gov (United States)

    Nair, Abhilash T; Ahammed, M Mansoor

    2014-09-01

    In the present study, feasibility of recovering the coagulant from water treatment plant sludge with sulphuric acid and reusing it in post-treatment of upflow anaerobic sludge blanket (UASB) reactor effluent treating municipal wastewater were studied. The optimum conditions for coagulant recovery from water treatment plant sludge were investigated using response surface methodology (RSM). Sludge obtained from plants that use polyaluminium chloride (PACl) and alum coagulant was utilised for the study. Effect of three variables, pH, solid content and mixing time was studied using a Box-Behnken statistical experimental design. RSM model was developed based on the experimental aluminium recovery, and the response plots were developed. Results of the study showed significant effects of all the three variables and their interactions in the recovery process. The optimum aluminium recovery of 73.26 and 62.73 % from PACl sludge and alum sludge, respectively, was obtained at pH of 2.0, solid content of 0.5 % and mixing time of 30 min. The recovered coagulant solution had elevated concentrations of certain metals and chemical oxygen demand (COD) which raised concern about its reuse potential in water treatment. Hence, the coagulant recovered from PACl sludge was reused as coagulant for post-treatment of UASB reactor effluent treating municipal wastewater. The recovered coagulant gave 71 % COD, 80 % turbidity, 89 % phosphate, 77 % suspended solids and 99.5 % total coliform removal at 25 mg Al/L. Fresh PACl also gave similar performance but at higher dose of 40 mg Al/L. The results suggest that coagulant can be recovered from water treatment plant sludge and can be used to treat UASB reactor effluent treating municipal wastewater which can reduce the consumption of fresh coagulant in wastewater treatment.

  18. Irregular echogenic foci representing coagulation necrosis: a useful but perhaps under-recognized EUS echo feature of malignant lymph node invasion.

    Science.gov (United States)

    Bhutani, Manoop S; Saftoiu, Adrian; Chaya, Charles; Gupta, Parantap; Markowitz, Avi B; Willis, Maurice; Kessel, Ivan; Sharma, Gulshan; Zwischenberger, Joseph B

    2009-06-01

    Coagulation necrosis has been described in malignant lymph nodes. Our aim was to determine if coagulation necrosis in mediastinal lymph nodes imaged by EUS could be used as a useful echo feature for predicting malignant invasion. Patients with known or suspected lung cancer who had undergone mediastinal lymph node staging by EUS. Tertiary Care university hospital. An expert endosonographer blinded to the final diagnosis, reviewed the archived digital EUS images of lymph nodes prior to being sampled by FNA. LNs positive for malignancy by FNA were included. The benign group included lymph node images with either negative EUS-FNA or lymph nodes imaged by EUS but not subjected to EUS-FNA, with surgical correlation of their benign nature. 24 patients were included. 8 patients were found to have coagulation necrosis. 7/8 patients had positive result for malignancy by EUS-FNA. One patient determined to have coagulation necrosis had a non-malignant diagnosis indicating a false positive result. 16 patients had no coagulation necrosis. In 6 patients with no coagulation necrosis, the final diagnosis was malignant and in the remaining 10 cases, the final diagnosis was benign. For coagulation necrosis as an echo feature for malignant invasion, sensitivity was 54%, specificity was 91%, positive predictive value was 88%, negative predictive value was 63% and accuracy was 71%. Coagulation necrosis is a useful echo feature for mediastinal lymph node staging by EUS.

  19. Network-Based Biomarkers for Cold Coagulation Blood Stasis Syndrome and the Therapeutic Effects of Shaofu Zhuyu Decoction in Rats

    Directory of Open Access Journals (Sweden)

    Shulan Su

    2013-01-01

    Full Text Available In this study, the reverse docking methodology was applied to predict the action targets and pathways of Shaofu Zhuyu decoction (SFZYD bioactive ingredients. Furthermore, Traditional Chinese Medicine (TCM cold coagulation blood stasis (CCBS syndrome was induced in female Sprague-Dawley rats with an ice-water bath and epinephrine, and SFZYD was used to treat CCBS syndrome. A metabolomic approach was used to evaluate changes in the metabolic profiles and to analyze the pharmacological mechanism of SFZYD actions. Twenty-three potential protein targets and 15 pathways were discovered, respectively; among these, pathways are associated with inflammation and immunological stress, hormone metabolism, coagulation function, and glycometabolism. There were also changes in the levels of endogenous metabolites of LysoPCs and glucuronides. Twenty endogenous metabolites were identified. Furthermore, the relative quantities of 6 endogenous metabolites in the plasma and 5 in the urine were significantly affected by SFZYD (P<0.05. The pharmacological mechanism of SFZYD was partially associated with glycerophospholipid metabolism and pentose and glucuronate interconversions. In conclusion, our findings demonstrated that TCM CCBS pattern induced by ice water and epinephrine was complex and related to multiple metabolic pathways. SFZYD did regulate the TCM CCBS by multitargets, and biomarkers and SFZYD should be used for the clinical treatment of CCBS syndrome.

  20. Using the Electronic Medical Record to Reduce Unnecessary Ordering of Coagulation Studies for Patients with Chest Pain

    Directory of Open Access Journals (Sweden)

    Jeremiah S. Hinson

    2017-02-01

    Full Text Available Introduction: Our goal was to reduce ordering of coagulation studies in the emergency department (ED that have no added value for patients presenting with chest pain. We hypothesized this could be achieved via implementation of a stopgap measure in the electronic medical record (EMR. Methods: We used a pre and post quasi-experimental study design to evaluate the impact of an EMRbased intervention on coagulation study ordering for patients with chest pain. A simple interactive prompt was incorporated into the EMR of our ED that required clinicians to indicate whether patients were on anticoagulation therapy prior to completion of orders for coagulation studies. Coagulation order frequency was measured via detailed review of randomly sampled encounters during two-month periods before and after intervention. We classified existing orders as clinically indicated or non-value added. Order frequencies were calculated as percentages, and we assessed differences between groups by chi-square analysis. Results: Pre-intervention, 73.8% (76/103 of patients with chest pain had coagulation studies ordered, of which 67.1% (51/76 were non-value added. Post-intervention, 38.5% (40/104 of patients with chest pain had coagulation studies ordered, of which 60% (24/40 were non-value added. There was an absolute reduction of 35.3% (95% confidence interval [CI]: 22.7%, 48.0% in the total ordering of coagulation studies and 26.4% (95% CI: 13.8%, 39.0% in non-value added order placement. Conclusion: Simple EMR-based interactive prompts can serve as effective deterrents to indiscriminate ordering of diagnostic studies. [West J Emerg Med. 2017;18(2267-269.

  1. Inherited coagulation factor VII and X deficiencies associated with severe bleeding diathesis: Molecular genetics and pathophysiology

    NARCIS (Netherlands)

    Borensztajn, K.; Spek, C. A.

    2005-01-01

    The rare inherited coagulation disorders are a fascinating group of diseases that have provided us with important insights into the structure and functions of their respective deficient proteins. Factor (F)VII deficiency is the commonest of these inherited disorders of coagulation, whereas FX

  2. Conventional Treatment of Surface Water Using Moringa Oleifera Seeds Extract as a Primary Coagulant

    Directory of Open Access Journals (Sweden)

    Suleyman A. Muyibi, Ahmed Hissein M Birima, Thamer A. Mohammed

    2012-10-01

    Full Text Available The present study involved the use of a model pilot scale water treatment plant to treat turbid surface water from a stream using processed Moringa oleifera seed with 25 % w/w oil extracted as primary coagulant. The water treatment plant was made up of four unit operations: coagulation, flocculation, sedimentation, and filtration (rapid sand filter. Test runs were carried out for three hours per run over a three-month period with turbidities ranging from 18 to 261 NTU. The turbidity, pH, and alkalinity as well as the filter head loss were measured every 30 minutes during the experimental runs. Average turbidity removal of up to 96 % at an effective doses of 20 and 30 mg/l of oil extracted M. oleifera for low (< 50 NTU and moderate turbidity (< 100 NTU water respectively was observed doses 50 – 80 mg/l for high turbidity (> 100 NTU water. M. oleifera seed extract was found to have no significant effect on pH or alkalinity of the water. The residual turbidities measured during most of the test runs satisfied the Malaysian Guideline for Drinking Water Supplies. Key Words: Moringa oleifera, primary coagulant, coagulation, pilot plant, filtration.

  3. [Application of electric coagulation treatment via bronchoscopy in the management of congenital vallecular cyst in children].

    Science.gov (United States)

    Liu, Xia; Ma, Jing; Zhao, Feng-mei; Zhang, Zhong-xiao; Niu, Tie-huan; Yan, Xiu-li; Wang, Chao; Meng, Chen

    2013-11-01

    To discuss the effect of electric coagulation through bronchoscopy in diagnosis and treatment of congenital vallecular cyst in children. Ten cases of congenital vallecular cyst in the study with age ranged from 21 days to 4 years and 10 months were treated with electric coagulation through bronchoscopy. The therapeutic effect was evaluated by endoscopic and clinical manifestation. And all the patients were followed-up for 6-12 months. All the patients obtained 3-5 times electric coagulation. After the operation, the cyst decreased in size, epiglottis softening was subsided, uplift uncompression, dyspnea and laryngeal stridor were improved obviously. After follow-up periods of 6-12 months, no capsule wall were left, and the activity of the epiglottis resumed.No severe complication was found in any patient. Electric coagulation through bronchoscopy is a simple, effective and safe method to treat congenital vallecular cyst in children.

  4. Effect of intravenous administration of dextrose on coagulation in healthy dogs.

    Science.gov (United States)

    Gonzales, Jennifer L; Hanel, Rita M; Hansen, Bernie D; Marks, Steve L

    2011-04-01

    To investigate effects of IV administration of dextrose on coagulation in healthy dogs. 7 dogs. Thromboelastography and coagulation panel analysis were used to assess coagulation. Samples (S1 through S9) were collected during the study phases: phase 0 (S1 [baseline]); phase 1 (S2 and S3), infusion of crystalloid fluid without dextrose; phase 2 (S4 and S5), high-rate dextrose infusion; phase 3 (S6, S7, and S8), moderate-rate dextrose infusion; and phase 4 (S9), discontinuation of fluids for 24 hours. In phase 3, dogs were allocated to 2 groups; 1 was administered dextrose at a rate comparable to total parental nutrition (40% of resting energy requirement; group A), and 1 was administered dextrose at rates equaling 70% to 90% of resting energy requirement (group B). Blood glucose concentration was measured every 2 hours. No dogs had clinically relevant sustained hyperglycemia. Maximum amplitude and elastic shear modulus were significantly lower at S6 than at S1 through S4. Concentration of D-dimer was significantly higher at S6 than at S1, S3, and S4 and significantly higher at S5 than at S3. Prothrombin time was significantly prolonged at S3, S5, S7, S8, and S9, compared with the value at S1. Activated partial thromboplastin time was significantly prolonged at S5 and S6, compared with values at S1, S2, S3, S4, and S9. IV administration of dextrose to healthy dogs at rates comparable to or higher than those for conventional parenteral nutrition resulted in mild but clinically unimportant interference with coagulation.

  5. Caveats in studies of the physiological role of polyphosphates in coagulation.

    Science.gov (United States)

    Lindahl, Tomas L; Ramström, Sofia; Boknäs, Niklas; Faxälv, Lars

    2016-02-01

    Platelet-derived polyphosphates (polyP), stored in dense granule and released upon platelet activation, have been claimed to enhance thrombin activation of coagulation factor XI (FXI) and to activate FXII directly. The latter claim is controversial and principal results leading to these conclusions are probably influenced by methodological problems. It is important to consider that low-grade contact activation is initiated by all surfaces and is greatly amplified by the presence of phospholipids simulating the procoagulant membranes of activated platelets. Thus, proper use of inhibitors of the contact pathway and a careful choice of materials for plates and tubes is important to avoid artefacts. The use of phosphatases used to degrade polyP has an important drawback as it also degrades the secondary activators ADP and ATP, which are released from activated platelets. In addition, the use of positively charged inhibitors, such as polymyxin B, to inhibit polyP in platelet-rich plasma and blood is problematic, as polymyxin B also slows coagulation in the absence of polyP. In conclusion we hope awareness of the above caveats may improve research on the physiological roles of polyP in coagulation. © 2016 Authors; published by Portland Press Limited.

  6. A review of studies of the activation of the blood coagulation mechanism in chimpanzees (Pan troglodytes)

    NARCIS (Netherlands)

    ten Cate, H.; Schenk, B. E.; Biemond, B. J.; Levi, M. [=Marcel M.; van der Poll, T.; Buller, H. R.; ten Cate, J. W.

    1994-01-01

    This paper reviews our recent studies of blood coagulation activation in the chimpanzee which were carried out employing sensitive immunoassays that measure activation markers of blood coagulation in plasma. Infused factor VIIa activated both factors IX and X in vivo; this reaction depended on the

  7. Vinasse treatment using a vegetable-tannin coagulant and photocatalysis - doi: 10.4025/actascitechnol.v35i1.11011

    Directory of Open Access Journals (Sweden)

    Renata Padilha de Souza

    2013-01-01

    Full Text Available The large volume of sugar cane vinasse generated by alcohol distillation motivated current treatment to reduce vinasse volume by a concentration process and to eliminate pollutants in the wastewater. The vinasse concentration by the coagulation/flocculation process favored the use of the thickened sludge either for fertilizing purposes or for biogas production. The photocatalysis treatment of the clarified vinasse mineralized pollutants and reduced toxicity, with subsequent water reuse. The first series of coagulation/flocculation experiments were carried out in a jar-test apparatus at room temperature with samples of 200 mL and several coagulant concentrations. In the second series of experiments, photocatalysis tests were performed on the clarified vinasse obtained by coagulation/flocculation under conditions optimized in the first series of experiments. The photocatalysis tests were performed for five consecutive days with UV irradiation, using TiO2-P25 as photocatalyst. Significant reduction of toxicity, consistent with the reduction in chemical oxygen demand (COD, was found when the photocatalysis treatment subsequent to coagulation/flocculation process was employed. Further, 98% reduction of turbidity and 87% reduction of color were obtained by the coagulation/flocculation process. Coupled to the photocatalysis process, significant reductions in absorbance, toxicity and COD (80% were also achieved.  

  8. Preliminary clinical evaluation of a noninvasive device for the measurement of coagulability in the elderly.

    Science.gov (United States)

    Lerman, Yaffa; Werber, Moshe M; Fine, Ilya; Kemelman, Polina

    2011-01-01

    The feasibility of the noninvasive assessment of blood 'coagulability' (the tendency to coagulate) has been tested by using a novel device, the Thrombo-Monitor. It monitors, by using the principles of near infra-red (NIR) dynamic light scattering, the tendency of blood to create clots. The Thrombo-Monitor observes the very initial changes of blood viscosity, which occurs due to the temporarily induced stasis of capillary blood of the finger. One hundred and fifteen patients aged >65 years (matched by age and sex) participated in the study. Patients were initially divided into four groups based on the patient's medical therapy. The study groups were: warfarin, enoxaparin, aspirin and/or clopidogrel, and a control group. The medications were given according to the patient's comorbidities (eg, atrial fibrillation [AF], status post pulmonary embolism [S/p PE], status post cerebrovascular accident [S/p CVA]). The Thrombo-Monitor Index (TMI) is a noninvasive index, derived on the basis of laboratory test results of international normalized ratio (INR) and prothrombin time (PT) values. For the group of patients who were treated only with warfarin, TMI was adjusted by using the jackknife statistical approach to create maximum correlation and linearity with INR and PT values that ranged from 1.1 to 5.0. For all warfarin patients (N = 35) the TMI was found to have a good correlation with INR and PT values (R(2) = 0.64, P index is significantly correlated with INR and PT values.

  9. The effects of ropivacaine hydrochloride on coagulation and fibrinolysis. An assessment using thromboelastography.

    LENUS (Irish Health Repository)

    Porter, J M

    2012-02-03

    Amide local anaesthetics impair coagulation by inhibition of platelet function and enhanced fibrinolysis. The potential therefore exists that the presence of amide local anaesthetics in the epidural space could contribute to the therapeutic failure of an epidural autologous blood patch. Ropivacaine is an aminoamide local anaesthetic increasingly used for epidural analgesia and anaesthesia, particularly in obstetric practice. This study was undertaken to investigate whether concentrations of ropivacaine in blood, which could occur clinically in the epidural space, alter coagulation or fibrinolysis. Thromboelastography was used to assess clotting and fibrinolysis of blood to which ropivacaine had been added. Although modest alterations in maximum amplitude, coagulation time and alpha angle were observed, the effect of ropivacaine on clotting and fibrinolysis was not clinically significant. We conclude that it is unlikely that the presence of ropivacaine in the epidural space would reduce the efficacy of an early or prophylactic epidural blood patch.

  10. Structural characterization of coagulant Moringa oleifera Lectin and its effect on hemostatic parameters.

    Science.gov (United States)

    Luz, Luciana de Andrade; Silva, Mariana Cristina Cabral; Ferreira, Rodrigo da Silva; Santana, Lucimeire Aparecida; Silva-Lucca, Rosemeire Aparecida; Mentele, Reinhard; Oliva, Maria Luiza Vilela; Paiva, Patricia Maria Guedes; Coelho, Luana Cassandra Breitenbach Barroso

    2013-07-01

    Lectins are carbohydrate recognition proteins. cMoL, a coagulant Moringa oleifera Lectin, was isolated from seeds of the plant. Structural studies revealed a heat-stable and pH resistant protein with 101 amino acids, 11.67 theoretical pI and 81% similarity with a M. oleifera flocculent protein. Secondary structure content was estimated as 46% α-helix, 12% β-sheets, 17% β-turns and 25% unordered structures belonging to the α/β tertiary structure class. cMoL significantly prolonged the time required for blood coagulation, activated partial thromboplastin (aPTT) and prothrombin times (PT), but was not so effective in prolonging aPTT in asialofetuin presence. cMoL acted as an anticoagulant protein on in vitro blood coagulation parameters and at least on aPTT, the lectin interacted through the carbohydrate recognition domain. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. The effects of continuous venovenous hemofiltration on coagulation activation

    NARCIS (Netherlands)

    Bouman, Catherine S. C.; de Pont, Anne-Cornélie J. M.; Meijers, Joost C. M.; Bakhtiari, Kamran; Roem, Dorina; Zeerleder, Sacha; Wolbink, Gertjan; Korevaar, Johanna C.; Levi, Marcel; de Jonge, Evert

    2006-01-01

    INTRODUCTION: The mechanism of coagulation activation during continuous venovenous hemofiltration (CVVH) has not yet been elucidated. Insight into the mechanism(s) of hemostatic activation within the extracorporeal circuit could result in a more rational approach to anticoagulation. The aim of the

  12. Can Unmanned Aerial Systems (Drones Be Used for the Routine Transport of Chemistry, Hematology, and Coagulation Laboratory Specimens?

    Directory of Open Access Journals (Sweden)

    Timothy K Amukele

    Full Text Available Unmanned Aerial Systems (UAS or drones could potentially be used for the routine transport of small goods such as diagnostic clinical laboratory specimens. To the best of our knowledge, there is no published study of the impact of UAS transportation on laboratory tests.Three paired samples were obtained from each one of 56 adult volunteers in a single phlebotomy event (336 samples total: two tubes each for chemistry, hematology, and coagulation testing respectively. 168 samples were driven to the flight field and held stationary. The other 168 samples were flown in the UAS for a range of times, from 6 to 38 minutes. After the flight, 33 of the most common chemistry, hematology, and coagulation tests were performed. Statistical methods as well as performance criteria from four distinct clinical, academic, and regulatory bodies were used to evaluate the results.Results from flown and stationary sample pairs were similar for all 33 analytes. Bias and intercepts were <10% and <13% respectively for all analytes. Bland-Altman comparisons showed a mean difference of 3.2% for Glucose and <1% for other analytes. Only bicarbonate did not meet the strictest (Royal College of Pathologists of Australasia Quality Assurance Program performance criteria. This was due to poor precision rather than bias. There were no systematic differences between laboratory-derived (analytic CV's and the CV's of our flown versus terrestrial sample pairs however CV's from the sample pairs tended to be slightly higher than analytic CV's. The overall concordance, based on clinical stratification (normal versus abnormal, was 97%. Length of flight had no impact on the results.Transportation of laboratory specimens via small UASs does not affect the accuracy of routine chemistry, hematology, and coagulation tests results from selfsame samples. However it results in slightly poorer precision for some analytes.

  13. Can Unmanned Aerial Systems (Drones) Be Used for the Routine Transport of Chemistry, Hematology, and Coagulation Laboratory Specimens?

    Science.gov (United States)

    Amukele, Timothy K; Sokoll, Lori J; Pepper, Daniel; Howard, Dana P; Street, Jeff

    2015-01-01

    Unmanned Aerial Systems (UAS or drones) could potentially be used for the routine transport of small goods such as diagnostic clinical laboratory specimens. To the best of our knowledge, there is no published study of the impact of UAS transportation on laboratory tests. Three paired samples were obtained from each one of 56 adult volunteers in a single phlebotomy event (336 samples total): two tubes each for chemistry, hematology, and coagulation testing respectively. 168 samples were driven to the flight field and held stationary. The other 168 samples were flown in the UAS for a range of times, from 6 to 38 minutes. After the flight, 33 of the most common chemistry, hematology, and coagulation tests were performed. Statistical methods as well as performance criteria from four distinct clinical, academic, and regulatory bodies were used to evaluate the results. Results from flown and stationary sample pairs were similar for all 33 analytes. Bias and intercepts were <10% and <13% respectively for all analytes. Bland-Altman comparisons showed a mean difference of 3.2% for Glucose and <1% for other analytes. Only bicarbonate did not meet the strictest (Royal College of Pathologists of Australasia Quality Assurance Program) performance criteria. This was due to poor precision rather than bias. There were no systematic differences between laboratory-derived (analytic) CV's and the CV's of our flown versus terrestrial sample pairs however CV's from the sample pairs tended to be slightly higher than analytic CV's. The overall concordance, based on clinical stratification (normal versus abnormal), was 97%. Length of flight had no impact on the results. Transportation of laboratory specimens via small UASs does not affect the accuracy of routine chemistry, hematology, and coagulation tests results from selfsame samples. However it results in slightly poorer precision for some analytes.

  14. Removal of disinfection by-product precursors by coagulation and an innovative suspended ion exchange process.

    Science.gov (United States)

    Metcalfe, David; Rockey, Chris; Jefferson, Bruce; Judd, Simon; Jarvis, Peter

    2015-12-15

    This investigation aimed to compare the disinfection by-product formation potentials (DBPFPs) of three UK surface waters (1 upland reservoir and 2 lowland rivers) with differing characteristics treated by (a) a full scale conventional process and (b) pilot scale processes using a novel suspended ion exchange (SIX) process and inline coagulation (ILCA) followed by ceramic membrane filtration (CMF). Liquid chromatography-organic carbon detection analysis highlighted clear differences between the organic fractions removed by coagulation and suspended ion exchange. Pretreatments which combined SIX and coagulation resulted in significant reductions in dissolved organic carbon (DOC), UV absorbance (UVA), trihalomethane and haloacetic acid formation potential (THMFP, HAAFP), in comparison with the SIX or coagulation process alone. Further experiments showed that in addition to greater overall DOC removal, the processes also reduced the concentration of brominated DBPs and selectively removed organic compounds with high DBPFP. The SIX/ILCA/CMF process resulted in additional removals of DOC, UVA, THMFP, HAAFP and brominated DBPs of 50, 62, 62, 62% and 47% respectively compared with conventional treatment. Copyright © 2015. Published by Elsevier Ltd.

  15. Spontaneous subdural hematoma of the thoracolumbar region with massive recurrent bleed

    Directory of Open Access Journals (Sweden)

    Cincu Rafael

    2009-01-01

    Full Text Available Spinal subdural hematoma is a rare disorder and can be caused by abnormalities of coagulation, blood dyscrasias, lumbar puncture, trauma, underlying neoplasm, and arteriovenous malformation. We discuss an unusual case of an elderly woman who presented with spontaneous spinal subdural hematoma and developed massive rebleeding on the third day following initial evacuation of hematoma. This case illustrates that a patient with routine normal coagulation profile and adequate hemostasis can still harbor platelet dysfunction (in present case due to polycythemia and later on can manifest as rebleeding and neurological deterioration.

  16. Transcatheter Arterial Embolization for Postpartum Hemorrhage with Disseminated Intravascular Coagulation: Outcome Assessment

    Energy Technology Data Exchange (ETDEWEB)

    An, Eun Jung; Kim, Young Hwan; Kwon, Bo Ra; Kim, See Hyung [Dept. of Radiology, Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2011-12-15

    We evaluated the efficacy and predictors of clinical outcome after transcatheter arterial embolization (TAE) for treatment of postpartum hemorrhage with disseminated intravascular coagulation (DIC). Of 127 patients who underwent TAE for postpartum hemorrhage, 46 progressed to DIC (group 1), 81 showed normal range hematological parameters (group 2). We retrospectively evaluated etiology, embolization methods and the efficacy of TAE for intergroup comparison Pearson Chi-Square test and logistic regression model. Overall TAE failed to control bleeding in 9 patients in spite of technical success. Lower bleeding control rate was found in group 2 (82.6%) relative to group 1 (98.8%, p = 0.001). And embolization methods were not statistically different between two groups no statistically significant predictors associated with failed hemostasis except the amount of transfusion in group 1. Although bleeding control rate is lower in postpartum hemorrhage with DIC than without DIC, we believe that TAE with correction of DIC is an effective method for postpartum hemorrhage with DIC.

  17. Transcatheter Arterial Embolization for Postpartum Hemorrhage with Disseminated Intravascular Coagulation: Outcome Assessment

    International Nuclear Information System (INIS)

    An, Eun Jung; Kim, Young Hwan; Kwon, Bo Ra; Kim, See Hyung

    2011-01-01

    We evaluated the efficacy and predictors of clinical outcome after transcatheter arterial embolization (TAE) for treatment of postpartum hemorrhage with disseminated intravascular coagulation (DIC). Of 127 patients who underwent TAE for postpartum hemorrhage, 46 progressed to DIC (group 1), 81 showed normal range hematological parameters (group 2). We retrospectively evaluated etiology, embolization methods and the efficacy of TAE for intergroup comparison Pearson Chi-Square test and logistic regression model. Overall TAE failed to control bleeding in 9 patients in spite of technical success. Lower bleeding control rate was found in group 2 (82.6%) relative to group 1 (98.8%, p = 0.001). And embolization methods were not statistically different between two groups no statistically significant predictors associated with failed hemostasis except the amount of transfusion in group 1. Although bleeding control rate is lower in postpartum hemorrhage with DIC than without DIC, we believe that TAE with correction of DIC is an effective method for postpartum hemorrhage with DIC.

  18. Embryonic miRNA profiles of normal and ectopic pregnancies.

    Directory of Open Access Journals (Sweden)

    Francisco Dominguez

    Full Text Available Our objective was to investigate the miRNA profile of embryonic tissues in ectopic pregnancies (EPs and controlled abortions (voluntary termination of pregnancy; VTOP. Twenty-three patients suffering from tubal EP and twenty-nine patients with a normal ongoing pregnancy scheduled for a VTOP were recruited. Embryonic tissue samples were analyzed by miRNA microarray and further validated by real time PCR. Microarray studies showed that four miRNAs were differentially downregulated (hsa-mir-196b, hsa-mir-30a, hsa-mir-873, and hsa-mir-337-3p and three upregulated (hsa-mir-1288, hsa-mir-451, and hsa-mir-223 in EP compared to control tissue samples. Hsa-miR-196, hsa-miR-223, and hsa-miR-451 were further validated by real time PCR in a wider population of EP and control samples. We also performed a computational analysis to identify the gene targets and pathways which might be modulated by these three differentially expressed miRNAs. The most significant pathways found were the mucin type O-glycan biosynthesis and the ECM-receptor-interaction pathways. We also checked that the dysregulation of these three miRNAs was able to alter the expression of the gene targets in the embryonic tissues included in these pathways such as GALNT13 and ITGA2 genes. In conclusion, analysis of miRNAs in ectopic and eutopic embryonic tissues shows different expression patterns that could modify pathways which are critical for correct implantation, providing new insights into the understanding of ectopic implantation in humans.

  19. Coagulation performance and floc characteristics of polytitanium tetrachloride (PTC) compared with titanium tetrachloride (TiCl4) and ferric chloride (FeCl3) in algal turbid water

    KAUST Repository

    Chekli, L.; Eripret, C.; Park, S.H.; Tabatabai, S. Assiyeh Alizadeh; Vronska, O.; Tamburic, B.; Kim, J.H.; Shon, H.K.

    2016-01-01

    Seasonal green algae blooms in freshwaters have raised attention on the need to develop novel effective treatment processes for the removal of algae in water. In the present study, the performance of newly developed polytitanium tetrachloride (PTC) coagulant for the removal of freshwater microalga Chlorella vulgaris has been investigated and compared with titanium tetrachloride (TiCl4) coagulant and the conventional ferric chloride (FeCl3) coagulant. The main benefit of using titanium-based coagulants is that the sludge produced after flocculation may be recycled into a valuable product: titanium dioxide photocatalyst. Both titanium-based coagulants achieved good flocculation over a broader pH range and coagulant dose compared to conventional FeCl3 coagulant. All three coagulants achieved comparable performance in terms of turbidity removal (i.e. turbidity removal efficiency >97%); although TiCl4 performed slightly better at the lower tested dose (i.e. <9 mg/L). Zeta potential measurements indicated that charge neutralisation may not be the sole mechanism involved in the coagulation of algae for all three coagulants. Analysis of the dynamic floc size variation during floc breakage showed no regrowth after floc breakage for the three coagulants. The flocs formed by both Ti-based coagulants were larger than those formed by FeCl3 and also grew at a faster rate. This study indicates that Ti-based coagulants are effective and promising coagulants for algae removal in water.

  20. Coagulation performance and floc characteristics of polytitanium tetrachloride (PTC) compared with titanium tetrachloride (TiCl4) and ferric chloride (FeCl3) in algal turbid water

    KAUST Repository

    Chekli, L.

    2016-11-11

    Seasonal green algae blooms in freshwaters have raised attention on the need to develop novel effective treatment processes for the removal of algae in water. In the present study, the performance of newly developed polytitanium tetrachloride (PTC) coagulant for the removal of freshwater microalga Chlorella vulgaris has been investigated and compared with titanium tetrachloride (TiCl4) coagulant and the conventional ferric chloride (FeCl3) coagulant. The main benefit of using titanium-based coagulants is that the sludge produced after flocculation may be recycled into a valuable product: titanium dioxide photocatalyst. Both titanium-based coagulants achieved good flocculation over a broader pH range and coagulant dose compared to conventional FeCl3 coagulant. All three coagulants achieved comparable performance in terms of turbidity removal (i.e. turbidity removal efficiency >97%); although TiCl4 performed slightly better at the lower tested dose (i.e. <9 mg/L). Zeta potential measurements indicated that charge neutralisation may not be the sole mechanism involved in the coagulation of algae for all three coagulants. Analysis of the dynamic floc size variation during floc breakage showed no regrowth after floc breakage for the three coagulants. The flocs formed by both Ti-based coagulants were larger than those formed by FeCl3 and also grew at a faster rate. This study indicates that Ti-based coagulants are effective and promising coagulants for algae removal in water.

  1. Coagulation factor XI improves host defence during murine pneumonia-derived sepsis independent of factor XII activation

    NARCIS (Netherlands)

    Stroo, Ingrid; Zeerleder, Sacha; Ding, Chao; Luken, Brenda M.; Roelofs, Joris J. T. H.; de Boer, Onno J.; Meijers, Joost C. M.; Castellino, Francis J.; van 't Veer, Cornelis; van der Poll, Tom

    2017-01-01

    Bacterial pneumonia, the most common cause of sepsis, is associated with activation of coagulation. Factor XI (FXI), the key component of the intrinsic pathway, can be activated via factor XII (FXII), part of the contact system, or via thrombin. To determine whether intrinsic coagulation is involved

  2. Production and characterization of water treatment coagulant from ...

    African Journals Online (AJOL)

    Base on high cost in coagulant for treating both domestic and industrial water in the recent time. There is need to identify cheaper and efficient methods of removing contaminant as the demand for clean water increases. A study was carried out to investigate the use of locally sourced Kaolinite clay from Okefomo ...

  3. Whole blood coagulation time, haematocrit, haemoglobin and total ...

    African Journals Online (AJOL)

    The study was carried out to determine the values of whole blood coagulation time (WBCT), haematocrit (HM), haemaglobin (HB) and total protein (TP) of one hundred and eighteen apparently healthy turkeys reared under an extensive management system in Zaria. The mean values for WBCT, HM, HB and TP were 1.12 ...

  4. Self-production of tissue factor-coagulation factor VII complex by ovarian cancer cells.

    Science.gov (United States)

    Yokota, N; Koizume, S; Miyagi, E; Hirahara, F; Nakamura, Y; Kikuchi, K; Ruf, W; Sakuma, Y; Tsuchiya, E; Miyagi, Y

    2009-12-15

    Thromboembolic events are a major complication in ovarian cancer patients. Tissue factor (TF) is frequently overexpressed in ovarian cancer tissue and correlates with intravascular thrombosis. TF binds to coagulation factor VII (fVII), changing it to its active form, fVIIa. This leads to activation of the extrinsic coagulation cascade. fVII is produced by the liver and believed to be supplied from blood plasma at the site of coagulation. However, we recently showed that ovarian cancer cells express fVII transcripts under normoxia and that this transcription is inducible under hypoxia. These findings led us to hypothesise that ovarian cancer cells are intrinsically associated with TF-fVIIa coagulation activity, which could result in thrombosis. In this study, we examined whether ectopically expressed fVII could cause thrombosis by means of immunohistochemistry, RT-PCR, western blotting and flow cytometry. Ectopic fVII expression occurs frequently in ovarian cancers, particularly in clear cell carcinoma. We further showed that ovarian cancer cells express TF-fVIIa on the cell surface under normoxia and that this procoagulant activity is enhanced by hypoxic stimuli. Moreover, we showed that ovarian cancer cells secrete microparticles (MPs) with TF-fVIIa activity. Production of this procoagulant secretion is enhanced under hypoxia. These results raise the possibility that cancer cell-derived TF-fVIIa could cause thrombotic events in ovarian cancer patients.

  5. In Vitro impairment of whole blood coagulation and platelet function by hypertonic saline hydroxyethyl starch

    Directory of Open Access Journals (Sweden)

    Görlinger Klaus

    2011-02-01

    Full Text Available Abstract Background Hypertonic saline hydroxyethyl starch (HH has been recommended for first line treatment of hemorrhagic shock. Its effects on coagulation are unclear. We studied in vitro effects of HH dilution on whole blood coagulation and platelet function. Furthermore 7.2% hypertonic saline, 6% hydroxyethylstarch (as ingredients of HH, and 0.9% saline solution (as control were tested in comparable dilutions to estimate specific component effects of HH on coagulation. Methods The study was designed as experimental non-randomized comparative in vitro study. Following institutional review board approval and informed consent blood samples were taken from 10 healthy volunteers and diluted in vitro with either HH (HyperHaes®, Fresenius Kabi, Germany, hypertonic saline (HT, 7.2% NaCl, hydroxyethylstarch (HS, HAES6%, Fresenius Kabi, Germany or NaCl 0.9% (ISO in a proportion of 5%, 10%, 20% and 40%. Coagulation was studied in whole blood by rotation thrombelastometry (ROTEM after thromboplastin activation without (ExTEM and with inhibition of thrombocyte function by cytochalasin D (FibTEM, the latter was performed to determine fibrin polymerisation alone. Values are expressed as maximal clot firmness (MCF, [mm] and clotting time (CT, [s]. Platelet aggregation was determined by impedance aggregrometry (Multiplate after activation with thrombin receptor-activating peptide 6 (TRAP and quantified by the area under the aggregation curve (AUC [aggregation units (AU/min]. Scanning electron microscopy was performed to evaluate HyperHaes induced cell shape changes of thrombocytes. Statistics: 2-way ANOVA for repeated measurements, Bonferroni post hoc test, p Results Dilution impaired whole blood coagulation and thrombocyte aggregation in all dilutions in a dose dependent fashion. In contrast to dilution with ISO and HS, respectively, dilution with HH as well as HT almost abolished coagulation (MCFExTEM from 57.3 ± 4.9 mm (native to 1.7 ± 2.2 mm (HH 40

  6. Toward understanding the efficacy and mechanism of Opuntia spp. as a natural coagulant for potential application in water treatment.

    Science.gov (United States)

    Miller, Sarah M; Fugate, Ezekiel J; Craver, Vinka Oyanedel; Smith, James A; Zimmerman, Julie B

    2008-06-15

    Historically, there is evidence to suggest that communities in the developing world have used plant-based materials as one strategy for purifying drinking water. In this study, the coagulant properties of Opuntia spp., a species of cactus, are quantitatively evaluated for the first time. Opuntia spp. was evaluated for turbidity removal from synthetic water samples, and steps were made toward elucidating the underlying coagulation mechanism. In model turbid water using kaolin clay particles at pH 10, Opuntia spp. reduced turbidity by 98% for a range of initial turbidities. This is similar to the observed coagulation activities previously described for Moringa oleifera, a widely studied natural coagulant. Although it has been reported that Moringa oleifera predominantly operates through charge neutralization, comparison of zeta potential measurements and transmission electron microscopy images of flocs formed by Opuntia spp. suggest that these natural coagulants operate through different mechanisms. It is suggested that Opuntia spp. operates predominantly through a bridging coagulation mechanism. Once optimized, application of these readily available plants as a part of point-of-use water treatment technology may offer a practical, inexpensive, and appropriate solution for producing potable water in some developing communities.

  7. Upregulation of the coagulation factor VII gene during glucose deprivation is mediated by activating transcription factor 4.

    Science.gov (United States)

    Cronin, Katherine R; Mangan, Thomas P; Carew, Josephine A

    2012-01-01

    Constitutive production of blood coagulation proteins by hepatocytes is necessary for hemostasis. Stressful conditions trigger adaptive cellular responses and delay processing of most proteins, potentially affecting plasma levels of proteins secreted exclusively by hepatocytes. We examined the effect of glucose deprivation on expression of coagulation proteins by the human hepatoma cell line, HepG2. Expression of coagulation factor VII, which is required for initiation of blood coagulation, was elevated by glucose deprivation, while expression of other coagulation proteins decreased. Realtime PCR and ELISA demonstrated that the relative percentage expression +/- SD of steady-state F7 mRNA and secreted factor VII antigen were significantly increased (from 100+/-15% to 188+/-27% and 100+/-8.8% to 176.3+/-17.3% respectively, pfactor ATF4 and of additional stress-responsive genes. Small interfering RNAs directed against ATF4 potently reduced basal F7 expression, and prevented F7 upregulation by glucose deprivation. The response of the endogenous F7 gene was replicated in reporter gene assays, which further indicated that ATF4 effects were mediated via interaction with an amino acid response element in the F7 promoter. Our data indicated that glucose deprivation enhanced F7 expression in a mechanism reliant on prior ATF4 upregulation primarily due to increased transcription from the ATF4 gene. Of five coagulation protein genes examined, only F7 was upregulated, suggesting that its functions may be important in a systemic response to glucose deprivation stress.

  8. Blocking of platelets or intrinsic coagulation pathway-driven thrombosis does not prevent cerebral infarctions induced by photothrombosis.

    Science.gov (United States)

    Kleinschnitz, Christoph; Braeuninger, Stefan; Pham, Mirko; Austinat, Madeleine; Nölte, Ingo; Renné, Thomas; Nieswandt, Bernhard; Bendszus, Martin; Stoll, Guido

    2008-04-01

    Models of photochemically-induced thrombosis are widely used in cerebrovascular research. Photothrombotic brain infarctions can be induced by systemic application of photosensitizing dyes followed by focal illumination of the cerebral cortex. Although the ensuing activation of platelets is well established, their contribution for thrombosis and tissue damage has not formally been proved. Infarction to the cerebral cortex was induced in mice by Rose Bengal and a cold light source. To assess the functional role of platelets, animals were platelet-depleted by anti-GPIbalpha antibodies or treated with GPIIb/IIIa-blocking F(ab)(2) fragments. The significance of the plasmatic coagulation cascade was determined by using blood coagulation factor XII (FXII)-deficient mice or heparin. Infarct development and infarct volumes were determined by serial MRI and conventional and electron microscopy. There was no difference in development and final size of photothrombotic infarctions in mice with impaired platelet function. Moreover, deficiency of FXII, which initiates the intrinsic pathway of coagulation and is essential for thrombus formation, or blockade of FXa, the key protease during the waterfall cascade of plasmatic coagulation, by heparin likewise did not affect lesion development. Our data demonstrate that platelet activation, factor XII-driven thrombus formation, and plasmatic coagulation pathways downstream of FX are not a prerequisite for ensuing tissue damage in models of photothrombotic vessel injury indicating that other pathomechanisms are involved. We suggest that this widely used model does not depend on platelet- or plasmatic coagulation-derived thrombosis.

  9. Intraventricular haemorrhage in preterm infants--can we improve outcome by addressing coagulation?

    Science.gov (United States)

    Kuperman, Amir A; Brenner, Benjamin; Kenet, Gili

    2015-11-01

    During the last few decades, the survival of preterm infants has increased dramatically. Nevertheless, with the increasing number of very young and extremely low birth weight infants, morbidity is still a major problem. Intraventricular Haemorrhage (IVH) is a major complication of preterm birth, and large haemorrhages or haemorrhages associated with parenchymal brain lesions may yield a high rate of future disability. IVH is a complex, multi-factorial disorder. Prematurity and low birth weight remain as its most important risk factors, affecting vulnerability of the germinal matrix as well as the coagulation system. Approximately 80% of IVHs occur by 72 h after birth, but a considerable proportion of IVH is already visible on the first cranial ultrasound scan within a few hours of birth. The hypothesis that a severe coagulation deficiency in the premature newborn could be a major contributing factor to IVH has been suggested, and small open label interventional studies targeting the premature coagulation system have been conducted with ethamsylate, vitamin K, fresh frozen plasma, recombinant activated factor VII and prothrombin complex concentrate. The outcome of these studies will be reviewed.

  10. A new balance formula to estimate new particle formation rate: reevaluating the effect of coagulation scavenging

    Directory of Open Access Journals (Sweden)

    R. Cai

    2017-10-01

    Full Text Available A new balance formula to estimate new particle formation rate is proposed. It is derived from the aerosol general dynamic equation in the discrete form and then converted into an approximately continuous form for analyzing data from new particle formation (NPF field campaigns. The new formula corrects the underestimation of the coagulation scavenging effect that occurred in the previously used formulae. It also clarifies the criteria for determining the upper size bound in measured aerosol size distributions for estimating new particle formation rate. An NPF field campaign was carried out from 7 March to 7 April 2016 in urban Beijing, and a diethylene glycol scanning mobility particle spectrometer equipped with a miniature cylindrical differential mobility analyzer was used to measure aerosol size distributions down to ∼ 1 nm. Eleven typical NPF events were observed during this period. Measured aerosol size distributions from 1 nm to 10 µm were used to test the new formula and the formulae widely used in the literature. The previously used formulae that perform well in a relatively clean atmosphere in which nucleation intensity is not strong were found to underestimate the comparatively high new particle formation rate in urban Beijing because of their underestimation or neglect of the coagulation scavenging effect. The coagulation sink term is the governing component of the estimated formation rate in the observed NPF events in Beijing, and coagulation among newly formed particles contributes a large fraction to the coagulation sink term. Previously reported formation rates in Beijing and in other locations with intense NPF events might be underestimated because the coagulation scavenging effect was not fully considered; e.g., estimated formation rates of 1.5 nm particles in this campaign using the new formula are 1.3–4.3 times those estimated using the formula neglecting coagulation among particles in the nucleation mode.

  11. The coagulation system in endocrine disorders: a narrative review

    NARCIS (Netherlands)

    Squizzato, A.; Gerdes, V. E. A.; Ageno, W.; Büller, H. R.

    2007-01-01

    Endocrine disorders can influence the haemostatic balance. Abnormal coagulation test results have been observed in patients with abnormal hormone levels. Also unprovoked bleeding or thrombotic events have been associated with endocrine disease. The aim of the present review is to summarise the

  12. Professional assessment of facial profile attractiveness.

    Science.gov (United States)

    Soh, Jen; Chew, Ming Tak; Wong, Hwee Bee

    2005-08-01

    The aim of this study was to compare the assessments of Chinese facial profile attractiveness by orthodontists and oral surgeons. The sample comprised 31 dental professionals (20 orthodontists, 11 oral surgeons) in an Asian community. Facial profile photographs and lateral cephalometric radiographs of 2 Chinese adults (1 man, 1 woman) with normal profiles, Class I incisor relationships, and Class I skeletal patterns were digitized. The digital images were modified by altering cephalometric skeletal and dental hard tissue Chinese normative values in increments of 2 standard deviations in the anteroposterior plane to obtain 7 facial profiles for each sex. The images were bimaxillary protrusion, protrusive mandible, retrusive mandible, normal profile (Class I incisor with Class I skeletal pattern), retrusive maxilla, protrusive maxilla, and bimaxillary retrusion. The Mann-Whitney U test was used to determine professional differences in assessment. Multiple regression analysis was performed with age, professional status, sex, and number of years in practice as independent variables. A strong correlation was found in the profile assessment between orthodontists and oral surgeons. Normal and bimaxillary retrusive Chinese male and female profiles were judged to be highly attractive by orthodontists and oral surgeons. Chinese male and female profiles with protrusive mandibles were judged the least attractive. There was a difference in professional opinion about the most attractive male profile (P profile and oral surgeons preferring a fuller normal Chinese profile. Sex of dental professionals and number of years in clinical practice were found to affect profile rankings.

  13. Mature landfill leachate treatment by coagulation/flocculation combined with Fenton and solar photo-Fenton processes.

    Science.gov (United States)

    Amor, Carlos; De Torres-Socías, Estefanía; Peres, José A; Maldonado, Manuel I; Oller, Isabel; Malato, Sixto; Lucas, Marco S

    2015-04-09

    This work reports the treatment of a mature landfill leachate through the application of chemical-based treatment processes in order to achieve the discharge legal limits into natural water courses. Firstly, the effect of coagulation/flocculation with different chemicals was studied, evaluating the role of different initial pH and chemicals concentration. Afterwards, the efficiency of two different advanced oxidation processes for leachate remediation was assessed. Fenton and solar photo-Fenton processes were applied alone and in combination with a coagulation/flocculation pre-treatment. This physicochemical conditioning step, with 2 g L(-1) of FeCl3 · 6H2O at pH 5, allowed removing 63% of COD, 80% of turbidity and 74% of total polyphenols. Combining the coagulation/flocculation pre-treatment with Fenton reagent, it was possible to reach 89% of COD removal in 96 h. Moreover, coagulation/flocculation combined with solar photo-Fenton revealed higher DOC (75%) reductions than single solar photo-Fenton (54%). In the combined treatment (coagulation/flocculation and solar photo-Fenton), it was reached a DOC reduction of 50% after the chemical oxidation, with 110 kJ L(-1) of accumulated UV energy and a H2O2 consumption of 116 mM. Toxicity and biodegradability assays were performed to evaluate possible variations along the oxidation processes. After the combined treatment, the leachate under study presented non-toxicity but biodegradability increased. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Effects of the oral, direct thrombin inhibitor dabigatran on five common coagulation assays.

    Science.gov (United States)

    Lindahl, Tomas L; Baghaei, Fariba; Blixter, Inger Fagerberg; Gustafsson, Kerstin M; Stigendal, Lennart; Sten-Linder, Margareta; Strandberg, Karin; Hillarp, Andreas

    2011-02-01

    Dabigatran is an oral, reversible thrombin inhibitor that has shown promising results in large clinical trials. Laboratory monitoring is not needed but the effects on common coagulation assays are incompletely known. Dabigatran was added to plasma from healthy subjects in the concentration range 0-1,000 μg/l and analysed using several reagents for activated thromboplastin time (APTT), prothrombin time (PT), fibrinogen, antithrombin, and activated protein C resistance. Typical trough concentrations are about 50 μg/l, peak concentrations 100-300 μg/l. At 100 μg/l all APTT-results were prolonged. The concentration required to double APTT ranged between 227 and 286 μg/l, the responses for all five reagents were similar. PT-reagents were much less affected with almost no samples above INR 1.2 at 100 μg/l. The effect was sample dilution dependent with PT Quick type more sensitive than PT Owren type methods. If a patient on dabigatran has prolonged APTT, >90 seconds, and Quick PT INR>2 or Owren PT INR>1.5 over-dosing or accumulation of dabigatran should be considered. Two of four fibrinogen reagents underestimated the fibrinogen concentration considerably at expected peak concentration. Methods based on inhibition of thrombin over-estimated the antithrombin concentration, but not Xa-based. The APC-resistance methods over-estimated the APC-ratio, which may lead to miss-classification of factor V Leiden patients as being normal. Different coagulation assays, and even different reagents within an assay group, display variable effects at therapeutic concentrations of dabigatran. Some of these assay variations are of clinical importance, thus knowledge is needed for a correct interpretation of results.

  15. THE EFFECTS OF GRADIENT VELOCITY AND DETENTION TIME TO COAGULATION – FLOCCULATION OF DYES AND ORGANIC COMPOUND IN DEEP WELL WATER

    Directory of Open Access Journals (Sweden)

    Muhamad Lindu

    2010-06-01

    Full Text Available The treatment of deep well water of Trisakti University by coagulation and flocculation using baffle channel system has been conducted. The detention time of hydrolic were varied. The coagulant dose was varied as 50, 100, 150, 200, 300, 350, 400, 450 and 500 ppm. Water of well sampel was added by coagulant with rotation velocity 200 rpm for 1 minute. The optimal coagulant dose was determined by measuring turbidity, colour, total suspended solids and organic compound. The result showed that the organic compound and colour of deep well water of Trisakti University could be reduced by coagulation and flocculation process by hydrolyc system. The optimal dose of the coagulant was 250 ppm. The removal efficiency of colour and organic compound using optimal dose for continuous flow reactor reached after water flow passed the reactor for 3 - 5 times detention time in the reactor. The optimal gradient velocity (G was 30 - 35 sec-1 and collision energy (GT was 65.000 - 79.000 to get optimal flocculation. With this condition, the removal efficiency of turbidity, colour and organic was more than 90%.   Keywords: coagulation, flocculation, colour, organic compound, deep well

  16. Predictive factors for beneficial application of high-frequency electromagnetics for tumour vaporization and coagulation in neurosurgery

    Directory of Open Access Journals (Sweden)

    Koerbel Andrei

    2008-04-01

    Full Text Available Abstract Objective To identify preoperative and intraoperative factors and conditions that predicts the beneficial application of a high-frequency electromagnetic field (EMF system for tumor vaporization and coagulation. Methods One hundred three subsequent patients with brain tumors were microsurgically treated using the EMF system in addition to the standard neurosurgical instrumentarium. A multivariate analysis was performed regarding the usefulness (ineffective/useful/very helpful/essential of the new technology for tumor vaporization and coagulation, with respect to tumor histology and location, tissue consistency and texture, patients' age and sex. Results The EMF system could be used effectively during tumor surgery in 83 cases with an essential contribution to the overall success in 14 cases. In the advanced category of effectiveness (very helpful/essential, there was a significant difference between hard and soft tissue consistency (50 of 66 cases vs. 3 of 37 cases. The coagulation function worked well (very helpful/essential for surface (73 of 103 cases and spot (46 of 103 cases coagulation when vessels with a diameter of less than one millimeter were involved. The light-weight bayonet hand piece and long malleable electrodes made the system especially suited for the resection of deep-seated lesions (34 of 52 cases compared to superficial tumors (19 of 50 cases. The EMF system was less effective than traditional electrosurgical devices in reducing soft glial tumors. Standard methods where also required for coagulation of larger vessels. Conclusion It is possible to identify factors and conditions that predict a beneficial application of high-frequency electromagnetics for tumor vaporization and coagulation. This allows focusing the use of this technology on selective indications.

  17. Coagulation of Agglomerates Consisting of Polydisperse Primary Particles.

    Science.gov (United States)

    Goudeli, E; Eggersdorfer, M L; Pratsinis, S E

    2016-09-13

    The ballistic agglomeration of polydisperse particles is investigated by an event-driven (ED) method and compared to the coagulation of spherical particles and agglomerates consisting of monodisperse primary particles (PPs). It is shown for the first time to our knowledge that increasing the width or polydispersity of the PP size distribution initially accelerates the coagulation rate of their agglomerates but delays the attainment of their asymptotic fractal-like structure and self-preserving size distribution (SPSD) without altering them, provided that sufficiently large numbers of PPs are employed. For example, the standard asymptotic mass fractal dimension, Df, of 1.91 is attained when clusters are formed containing, on average, about 15 monodisperse PPs, consistent with fractal theory and the literature. In contrast, when polydisperse PPs with a geometric standard deviation of 3 are employed, about 500 PPs are needed to attain that Df. Even though the same asymptotic Df and mass-mobility exponent, Dfm, are attained regardless of PP polydispersity, the asymptotic prefactors or lacunarities of Df and Dfm increase with PP polydispersity. For monodisperse PPs, the average agglomerate radius of gyration, rg, becomes larger than the mobility radius, rm, when agglomerates consist of more than 15 PPs. Increasing PP polydispersity increases that number of PPs similarly to the above for the attainment of the asymptotic Df or Dfm. The agglomeration kinetics are quantified by the overall collision frequency function. When the SPSD is attained, the collision frequency is independent of PP polydispersity. Accounting for the SPSD polydispersity in the overall agglomerate collision frequency is in good agreement with that frequency from detailed ED simulations once the SPSD is reached. Most importantly, the coagulation of agglomerates is described well by a monodisperse model for agglomerate and PP sizes, whereas the detailed agglomerate size distribution can be obtained by

  18. Treatment of Wastewater From Car Washes Using Natural Coagulation and Filtration System

    Science.gov (United States)

    Al-Gheethi, A. A.; Mohamed, R. M. S. R.; Rahman, M. A. A.; Johari, M. R.; Kassim, A. H. M.

    2016-07-01

    Wastewater generated from carwash is one of the main wastewater resources, which contribute effectively in the increasing of environmental contamination due to the chemical characteristics of the car wastes. The present work aimed to develop an integrated treatment system for carwash wastewater based on coagulation and flocculation using Moringa oleifera and Ferrous Sulphate (FeSO4.7H2O) as well as natural filtration system. The carwash wastewater samples were collected from carwash station located at Parit Raja, Johor, Malaysia. The treatment system of car wash wastewater was designed in the lab scale in four stages included, aeration, coagulation and flocculation, sedimentation and filtration. The coagulation and flocculation unit was carried out using different dosage (35, 70, 105 and 140 mg L-1) of M. oleifera and FeSO4.7H2O, respectively. The efficiency of the integrated treatment system to treat carwash wastewater and to meet Environmental Quality Act (EQA 1974) was evaluated based on the analysis of pH, dissolved oxygen (DO), chemical oxygen demand (COD) and turbidity (NTU). The integrated treatment system was efficient for treatment of raw carwash wastewater. The treated carwash wastewaters meet EQA 1974 regulation 2009 (Standards A) in the term of pH and DO while, turbidity and COD reduced in the wastewater to meet Standards B. The integrated treatment system designed here with natural coagulant (M. oleifera) and filtration unit were effective for primary treatment of carwash wastewater before the final disposal or to be reused again for carwash process.

  19. Impaired fasting glucose and the metabolic profile in Danish children and adolescents with normal weight, overweight, or obesity

    DEFF Research Database (Denmark)

    Kloppenborg, Julie T; Fonvig, Cilius E; Nielsen, Tenna R H

    2017-01-01

    OBJECTIVE: Whether the definitions of impaired fasting glucose (IFG) from the American Diabetes Association (ADA) and the World Health Organization (WHO) differentially impact estimates of the metabolic profile and IFG-related comorbidities in Danish children and adolescents is unknown. METHODS......: Two thousand one hundred and fifty four (979 boys) children and adolescents with overweight or obesity (median age 12 years) and 1824 (728 boys) children with normal weight (median age 12 years) from The Danish Childhood Obesity Biobank were studied. Anthropometrics, blood pressure, puberty......, and fasting concentrations of glucose, insulin, glycosylated hemoglobin (HbA1c), and lipids were measured. RESULTS: About 14.1% of participants with overweight or obesity exhibited IFG according to the ADA and 3.5% according to the WHO definition. Among individuals with normal weight, the corresponding...

  20. Investigation the Efficiency of Combined Coagulation and Advanced Oxidation by Fenton Process in the Removal of Clarithromycin Antibiotic COD

    Directory of Open Access Journals (Sweden)

    Ahmad Reza Yazdanbakhsh

    2012-07-01

    Full Text Available Antibiotics are considered among the major pollutants in water environments. In this study, removal of Claritromycine antibiotic has been studied from synthetic wastewater by combined coagulation and advanced oxidation processes. This study, was done in laboratory scale .  Samples of synthetic wastewater  were prepared from Claritromycin antibiotic. Concentration of samples were 200 mg/l. COD index was selected as a parameter evaluated in this study. In the first stage, coagulation process was done on synthetic wastewater and the proper condition was achieved (proper coagulant, optimum pH, dosage of coagulant. After that, Fenton oxidation process was done, on the effluent of coagulation process. In Fenton process the influence of pH, Fe2+ and hydrogen peroxide were studied on the removal efficiency of Claritromycin antibiotic and the optimum values for each parameter were determined. According to the results of this study, Poly Aluminum Chloride (PAC  is the proper coagulant. With pH equal to 7 and 100 mg/l PAC, 84.37% removal of Claritromycine was achieved.  For fenton process, optimum parameters for the removal of Claritromycin were determined. The optimum condition for fenton process were, pH= 7, Fe2+ equal to 0.45 mmol/ l , hydrogen proxide equal to 0. 16 mmol/l, ratio of H2O2/Fe2+ equal to 0.4 and detention time of 1hour .With Applying of optimum conditions for combined coagulation and Fenton processes, 96.3% removal of Claritromycin was obtained.

  1. Activation of factor VII bound to tissue factor: A key early step in the tissue factor pathway of blood coagulation

    International Nuclear Information System (INIS)

    Rao, L.V.M.; Rapaport, S.I.

    1988-01-01

    Whether the factor VII/tissue factor complex that forms in tissue factor-dependent blood coagulation must be activated to factor VIIa/tissue factor before it can activate its substrates, factor X and IX, has been a difficult question to answer because the substrates, once activated, back-activate factor VII. The earlier studies suggested that human factor VII/tissue factor cannot activate factor IX. Studies have now been extended to the activation of factor X. Reaction mixtures were made with purified factor VII, X, and tissue factor; in some experiments antithrombin III and heparin were added to prevent back-activation of factor VII. Factor X was activated at similar rates in reaction mixtures containing either VII or factor VIIa after an initial 30-sec lag with factor VII. In reaction mixtures with factor VII a linear activation of factor X was established several minutes before cleavage of 125 I-labeled factor VII to the two-chain activated molecule was demonstrable on gel profiles. These data suggest that factor VII/tissue factor cannot activate measurable amounts of factor X over several minutes. Overall, the results support the hypothesis that a rapid preferential activation of factor VII bound to tissue factor by trace amounts of factor Xa is a key early step in tissue factor-dependent blood coagulation

  2. Comparative study on plant latex particles and latex coagulation in Ficus benjamina, Campanula glomerata and three Euphorbia species.

    Directory of Open Access Journals (Sweden)

    Georg Bauer

    Full Text Available Among latex-producing plants, mainly the latex of Hevea brasiliensis has been studied in detail so far, while comprehensive comparative studies of latex coagulation mechanisms among the more than 20,000 latex-bearing plant species are lacking. In order to give new insights into the potential variety of coagulation mechanisms, the untreated natural latices of five latex-bearing plants from the families Euphorbiaceae, Moraceae and Campanulaceae were visualised using Cryo-SEM and their particle size compared using the laser diffraction method. Additionally, the laticifers of these plants species were examined in planta via Cryo-SEM. Similar latex particle sizes and shape were found in Ficus benjamina and Hevea brasiliensis. Hence, and due to other similarities, we hypothesize comparable, mainly chemical, coagulation mechanisms in these two species, whereas a physical coagulation mechanism is proposed for the latex of Euphorbia spp. The latter mechanism is based on the huge amount of densely packed particles that after evaporation of water build a large surface area, which accelerates the coagulation procedure.

  3. Discovery of a Parenteral Small Molecule Coagulation Factor XIa Inhibitor Clinical Candidate (BMS-962212).

    Science.gov (United States)

    Pinto, Donald J P; Orwat, Michael J; Smith, Leon M; Quan, Mimi L; Lam, Patrick Y S; Rossi, Karen A; Apedo, Atsu; Bozarth, Jeffrey M; Wu, Yiming; Zheng, Joanna J; Xin, Baomin; Toussaint, Nathalie; Stetsko, Paul; Gudmundsson, Olafur; Maxwell, Brad; Crain, Earl J; Wong, Pancras C; Lou, Zhen; Harper, Timothy W; Chacko, Silvi A; Myers, Joseph E; Sheriff, Steven; Zhang, Huiping; Hou, Xiaoping; Mathur, Arvind; Seiffert, Dietmar A; Wexler, Ruth R; Luettgen, Joseph M; Ewing, William R

    2017-12-14

    Factor XIa (FXIa) is a blood coagulation enzyme that is involved in the amplification of thrombin generation. Mounting evidence suggests that direct inhibition of FXIa can block pathologic thrombus formation while preserving normal hemostasis. Preclinical studies using a variety of approaches to reduce FXIa activity, including direct inhibitors of FXIa, have demonstrated good antithrombotic efficacy without increasing bleeding. On the basis of this potential, we targeted our efforts at identifying potent inhibitors of FXIa with a focus on discovering an acute antithrombotic agent for use in a hospital setting. Herein we describe the discovery of a potent FXIa clinical candidate, 55 (FXIa K i = 0.7 nM), with excellent preclinical efficacy in thrombosis models and aqueous solubility suitable for intravenous administration. BMS-962212 is a reversible, direct, and highly selective small molecule inhibitor of FXIa.

  4. Normalization to specific gravity prior to analysis improves information recovery from high resolution mass spectrometry metabolomic profiles of human urine.

    Science.gov (United States)

    Edmands, William M B; Ferrari, Pietro; Scalbert, Augustin

    2014-11-04

    Extraction of meaningful biological information from urinary metabolomic profiles obtained by liquid-chromatography coupled to mass spectrometry (MS) necessitates the control of unwanted sources of variability associated with large differences in urine sample concentrations. Different methods of normalization either before analysis (preacquisition normalization) through dilution of urine samples to the lowest specific gravity measured by refractometry, or after analysis (postacquisition normalization) to urine volume, specific gravity and median fold change are compared for their capacity to recover lead metabolites for a potential future use as dietary biomarkers. Twenty-four urine samples of 19 subjects from the European Prospective Investigation into Cancer and nutrition (EPIC) cohort were selected based on their high and low/nonconsumption of six polyphenol-rich foods as assessed with a 24 h dietary recall. MS features selected on the basis of minimum discriminant selection criteria were related to each dietary item by means of orthogonal partial least-squares discriminant analysis models. Normalization methods ranked in the following decreasing order when comparing the number of total discriminant MS features recovered to that obtained in the absence of normalization: preacquisition normalization to specific gravity (4.2-fold), postacquisition normalization to specific gravity (2.3-fold), postacquisition median fold change normalization (1.8-fold increase), postacquisition normalization to urinary volume (0.79-fold). A preventative preacquisition normalization based on urine specific gravity was found to be superior to all curative postacquisition normalization methods tested for discovery of MS features discriminant of dietary intake in these urinary metabolomic datasets.

  5. Effects of conjugated estrogens/bazedoxifene on lipid and coagulation variables

    DEFF Research Database (Denmark)

    Skouby, Sven O; Pan, Kaijie; Thompson, John R

    2015-01-01

    OBJECTIVE: This study aims to evaluate the effects of conjugated estrogens (CE)/bazedoxifene (BZA) on lipid and coagulation variables in a randomized, double-blind, placebo- and active-controlled phase 3 study of nonhysterectomized postmenopausal women. METHODS: The Selective estrogens, Menopause......, And Response to Therapy (SMART)-5 trial evaluated the efficacy and safety of CE/BZA in postmenopausal women (N = 1,843) with menopausal symptoms. Lipid (N = 1,843) and coagulation (N = 590) variables were assessed in women receiving daily CE 0.45 mg/BZA 20 mg, CE 0.625 mg/BZA 20 mg, BZA 20 mg, CE 0.45 mg...... reassurance that CE/BZA does not adversely affect lipid metabolism or hemostatic balance. In accordance, the incidences of venous thromboembolic events and cardiovascular events in postmenopausal women are similar to those observed with placebo....

  6. How to distinguish between bleeding and coagulated extradural hematomas on the plain CT scanning

    International Nuclear Information System (INIS)

    Petersen, O.F.; Espersen, J.O.

    1984-01-01

    Four types of extradural hematoma could be separated at examination of the plain CT scan in 54 extradural hematomas. Two major groups appear: the still bleeding hematoma showing either generally low attenuation values of ''holes'', and a coagulated homogenous type with generally high attenuation values. The attenuation values of the bleeding-liquid part of hematoma - were correlated to hemoglobin concentration in blood, to which clots were not related. Seven extradural hematomas grew and coagulated on repeated preoperative CT scans. In two cases intravenous contrast was given to the bleeding type of hematoma, and the contrast media appeared in ''holes'', but not in areas of high attenuation value. It is easy to distinguish between the different types of hematoma on the plain CT scan, and the separation by eye between the still bleeding and the coagulated extradural hematoma seems reliable. (orig.)

  7. Improvement of the coagulation/flocculation process using a combination of Moringa oleifera lam with anionic polymer in water treatment.

    Science.gov (United States)

    Bongiovani, Milene Carvalho; Camacho, Franciele Pereira; Nishi, Letícia; Coldebella, Priscila Ferri; Valverde, Karina Cardoso; Vieira, Angélica Marquetotti Salcedo; Bergamasco, Rosângela

    2014-01-01

    The objective of this study is to investigate the impacts of anionic polymer as a flocculant aid on the coagulation/flocculation performance with a saline solution of Moringa oleifera as a coagulant to provide larger flocs and decrease the time sedimentation. For the tests, raw water was used from Pirapó River Basin (Maringá, Paraná, Brazil). Optimization of coagulation/flocculation tests was initially performed in a jar-test with a dosage of M. oleifera Lam (crude extract--MO, oil-extracted with ethanol--MO (et) and hexane--MO (hex) 1% m/v) as the coagulant that ranged from 10 to 60 mg L(-1) and of the anionic polymer 0.1% as a flocculant aid with a dosage that ranged from 0 to 0.4 mg L(-1). The parameters analysed were colour, turbidity and compounds with absorption in UV254nm. In view of the statistical analysis results, MO (hex) with a dosage of 30 mg L(-1) was chosen as a coagulant for the next tests of coagulation/flocculation. When anionic polymer was used alone (0.0 mg L(-1) of MO (hex)), parameters were not removed and there was no generation of heavy flocs as compared with the combination of MO (hex) with the anionic polymer. Statistical analysis showed that MO (hex) obtained the highest removals of the parameters analysed in lower dosages and no significant increase in parameters removal was observed when the polymer dosage was increased. The efficacy of the coagulant +/- anionic polymer was optimal when 30mg L(-1) of MO (hex) was used as a coagulant and 0.1 mg L(-1) of the anionic polymer was used as a flocculant aid, decreasing the time sedimentation from 1 h to 15 min.

  8. The efficiency of combined coagulant and ballast to remove harmful cyanobacterial blooms in a tropical shallow system

    NARCIS (Netherlands)

    Miranda, Marcela; Noyma, Natalia; Pacheco, Felipe S.; de Magalhaes, Leonardo; Pinto, Ernani; Santos, Suzan; Soares, Maria Fernanda A.; Huszar, Vera L.; Lürling, Miquel; Marinho, Marcelo M.

    We tested the hypothesis that a combination of coagulant and ballast could be efficient for removal of positively buoyant harmful cyanobacteria in shallow tropical waterbodies, and will not promote the release of cyanotoxins. This laboratory study examined the efficacy of coagulants [polyaluminium

  9. The efficiency of combined coagulant and ballast to remove harmful cyanobacterial blooms in a tropical shallow system

    NARCIS (Netherlands)

    Miranda, Marcela; Noyma, Natália; Pacheco, Felipe S.; Magalhães, de Leonardo; Pinto, Ernani; Santos, Suzan; Soares, Maria Fernanda A.; Huszar, Vera L.; Lurling, Miguel; Marinho, Marcelo M.

    2017-01-01

    We tested the hypothesis that a combination of coagulant and ballast could be efficient for removal of positively buoyant harmful cyanobacteria in shallow tropical waterbodies, and will not promote the release of cyanotoxins. This laboratory study examined the efficacy of coagulants

  10. A bimodal temom model for particle Brownian coagulation in the continuum-slip regime

    Directory of Open Access Journals (Sweden)

    He Qing

    2016-01-01

    Full Text Available In this paper, a bimodal Taylor-series expansion moment of method is proposed to deal with Brownian coagulation in the continuum-slip regime, where the non-linear terms in the Cunningham correction factor is approximated by Taylor-series expansion technology. The results show that both the number concentration and volume fraction decrease with time in the smaller mode due to the intra and inter coagulation, and the asymptotic behavior of the larger mode is as same as that in the continuum regime.

  11. Innovative physico-chemical treatment of wastewater incorporating Moringa oleifera seed coagulant.

    Science.gov (United States)

    Bhuptawat, Hitendra; Folkard, G K; Chaudhari, Sanjeev

    2007-04-02

    Moringa oleifera is a pan tropical, multipurpose tree whose seeds contain a high quality edible oil (up to 40% by weight) and water soluble proteins that act as effective coagulants for water and wastewater treatment. The use of this natural coagulant material has not yet realised its potential. A water extract of M. oleifera seed was applied to a wastewater treatment sequence comprising coagulation-flocculation-sedimentation-sand filtration. The study was laboratory based using an actual wastewater. Overall COD removals of 50% were achieved at both 50 and 100mg/l M. oleifera doses. When 50 and 100mg/l seed doses were applied in combination with 10mg/l of alum, COD removal increased to 58 and 64%, respectively. The majority of COD removal occurred during the filtration process. In the tests incorporating alum, sludge generation and filter head loss increased by factors of 3 and 2, respectively. These encouraging treatment results indicate that this may be the first treatment application that can move to large scale adoption. The simple water extract may be obtained at minimal cost from the presscake residue remaining after oil extraction from the seed. The regulatory compliance issues of adopting 'new materials' for wastewater treatment are significantly less stringent than those applying to the production of potable water.

  12. MicroRNA and piRNA profiles in normal human testis detected by next generation sequencing.

    Directory of Open Access Journals (Sweden)

    Qingling Yang

    Full Text Available BACKGROUND: MicroRNAs (miRNAs are the class of small endogenous RNAs that play an important regulatory role in cells by negatively affecting gene expression at transcriptional and post-transcriptional levels. There have been extensive studies aiming to discover miRNAs and to analyze their functions in the cells from a variety of species. However, there are no published studies of miRNA profiles in human testis using next generation sequencing (NGS technology. RESULTS: We employed Solexa sequencing technology to profile miRNAs in normal human testis. Total 770 known and 5 novel human miRNAs, and 20121 piRNAs were detected, indicating that the human testis has a complex population of small RNAs. The expression of 15 known and 5 novel detected miRNAs was validated by qRT-PCR. We have also predicted the potential target genes of the abundant known and novel miRNAs, and subjected them to GO and pathway analysis, revealing the involvement of miRNAs in many important biological phenomenon including meiosis and p53-related pathways that are implicated in the regulation of spermatogenesis. CONCLUSIONS: This study reports the first genome-wide miRNA profiles in human testis using a NGS approach. The presence of large number of miRNAs and the nature of their target genes suggested that miRNAs play important roles in spermatogenesis. Here we provide a useful resource for further elucidation of the regulatory role of miRNAs and piRNAs in the spermatogenesis. It may also facilitate the development of prophylactic strategies for male infertility.

  13. Threshold-based prediction of the coagulation zone in sequential temperature mapping in MR-guided radiofrequency ablation of liver tumours

    Energy Technology Data Exchange (ETDEWEB)

    Rempp, Hansjoerg; Hoffmann, Ruediger; Buck, Alexandra; Claussen, Claus D.; Schick, Fritz; Clasen, Stephan [Eberhard Karls University of Tuebingen, Department on Diagnostic and Interventional Radiology, Tuebingen (Germany); Roland, Joerg; Kickhefel, Antje [Siemens Healthcare, Erlangen (Germany); Pereira, Philippe L. [Clinic for radiology, Nuclear Medicine and Minimal Invasive Therapies, SLK-Clinics, Heilbronn (Germany)

    2012-05-15

    To evaluate different cut-off temperature levels for a threshold-based prediction of the coagulation zone in magnetic resonance (MR)-guided radiofrequency (RF) ablation of liver tumours. Temperature-sensitive measurements were acquired during RF ablation of 24 patients with primary (6) and secondary liver lesions (18) using a wide-bore 1.5 T MR sytem and compared with the post-interventional coagulation zone. Temperature measurements using the proton resonance frequency shift method were performed directly subsequent to energy application. The temperature maps were registered on the contrast-enhanced follow-up MR images acquired 4 weeks after treatment. Areas with temperatures above 50 , 55 and 60 C were segmented and compared with the coagulation zones. Sensitivity and positive predictive value were calculated. No major complications occurred and all tumours were completely treated. No tumour recurrence was observed at the follow-up examination after 4 weeks. Two patients with secondary liver lesions showed local tumour recurrence after 4 and 7 months. The 60 C threshold level achieved the highest positive predictive value (87.7 {+-} 9.9) and the best prediction of the coagulation zone. For a threshold-based prediction of the coagulation zone, the 60 C cut-off level achieved the best prediction of the coagulation zone among the tested levels. (orig.)

  14. Threshold-based prediction of the coagulation zone in sequential temperature mapping in MR-guided radiofrequency ablation of liver tumours

    International Nuclear Information System (INIS)

    Rempp, Hansjoerg; Hoffmann, Ruediger; Buck, Alexandra; Claussen, Claus D.; Schick, Fritz; Clasen, Stephan; Roland, Joerg; Kickhefel, Antje; Pereira, Philippe L.

    2012-01-01

    To evaluate different cut-off temperature levels for a threshold-based prediction of the coagulation zone in magnetic resonance (MR)-guided radiofrequency (RF) ablation of liver tumours. Temperature-sensitive measurements were acquired during RF ablation of 24 patients with primary (6) and secondary liver lesions (18) using a wide-bore 1.5 T MR sytem and compared with the post-interventional coagulation zone. Temperature measurements using the proton resonance frequency shift method were performed directly subsequent to energy application. The temperature maps were registered on the contrast-enhanced follow-up MR images acquired 4 weeks after treatment. Areas with temperatures above 50 , 55 and 60 C were segmented and compared with the coagulation zones. Sensitivity and positive predictive value were calculated. No major complications occurred and all tumours were completely treated. No tumour recurrence was observed at the follow-up examination after 4 weeks. Two patients with secondary liver lesions showed local tumour recurrence after 4 and 7 months. The 60 C threshold level achieved the highest positive predictive value (87.7 ± 9.9) and the best prediction of the coagulation zone. For a threshold-based prediction of the coagulation zone, the 60 C cut-off level achieved the best prediction of the coagulation zone among the tested levels. (orig.)

  15. In vitro anti-thrombotic and anti-coagulant properties of blacklip abalone (Haliotis rubra) viscera hydrolysate.

    Science.gov (United States)

    Suleria, Hafiz Ansar Rasul; Masci, Paul P; Addepalli, Rama; Chen, Wei; Gobe, Glenda C; Osborne, Simone A

    2017-07-01

    Abalone viscera contain sulphated polysaccharides with anti-thrombotic and anti-coagulant activities. In this study, a hydrolysate was prepared from blacklip abalone (Haliotis rubra) viscera using papain and bromelain and fractionated using ion exchange and size exclusion chromatography. Hydrolysates and fractions were investigated for in vitro thrombin inhibition mediated through heparin cofactor II (HCII) as well as anti-coagulant activity in plasma and whole blood. On the basis of sulphated polysaccharide concentration, the hydrolysate inhibited thrombin through HCII with an inhibitor concentration at 50% (IC50) of 16.5 μg/mL compared with 2.1 μg/mL for standard heparin. Fractionation concentrated HCII-mediated thrombin inhibition down to an IC50 of 1.8 μg/mL and improved anti-coagulant activities by significantly delaying clotting time. This study confirmed the presence of anti-thrombotic and anti-coagulant molecules in blacklip abalone viscera and demonstrated that these activities can be enriched with a simple chromatography regime. Blacklip abalone viscera warrant further investigation as a source of nutraceutical or functional food ingredients. Graphical abstract Schematic showing preparation of bioactive extracts and fractions from blacklip abalone.

  16. Air quality improvement during 2010 Asian games on blood coagulability in COPD patients.

    Science.gov (United States)

    Zhang, Zili; Wang, Jian; Guo, Meihua; Xiong, Mingmei; Zhou, Qipeng; Li, Defu; Shu, Jiaze; Lu, Wenju; Sun, Dejun

    2016-04-01

    Exposure to elevated levels of ambient air pollutants can lead to adverse cardiovascular effects. Perturbation of the coagulation balance is one of the potential mechanisms. However, evidence regarding the impact of improvement in air pollution on blood coagulability in COPD patients has never been reported. Coagulation processes are known to be of relevance for cardiovascular pathology; therefore, this study aimed to investigate the association of short-term air pollution exposure with blood marker (D-dimer) of coagulation. A 3-year (through the Asian game) cohort study based on the GIRD COPD Biobank Project was conducted in 36 COPD patients to estimate whether changes in measurements of D-dimer were associated with changes in pollutant concentration, comparing for 51 intervention days (November 1-December 21) in 2010 with the same calendar date of baseline years (2009 and 2011). Daily mean concentrations of air pollutants and meteorological variables were measured during the time. Daily PM10 decreased from 65.86 μg/m(3) during the baseline period to 62.63 μg/m(3) during the Asian Games period; daily NO2 decreased from 51.33 to 42.63 μg/m(3). SO2 and other weather variables did not differ substantially. We did not observe statistically significant improvements in D-dimer levels by 9.86% from a pre-Asian game mean of 917 ng/ml to a during-Asian game mean of 1007 ng/ml, platelet number by 11.66%, PH by -0.15%, PCO2 by -6.54%, and PO2 by -1.16%. In the post-Asian game period, when pollutant concentrations increased, most outcomes approximated pre-Asian game levels, and similar effects were also demonstrated in D-dimer, platelet number, and arterial blood gas. For D-dimer and platelet number, we observed statistically significant increases associated with increases in NO2 at lag 1-3 and SO2 at lag 2-4. For PH, PCO2, and PO2, any significant effect was not demonstrated. This study gives no support to the hypothesis that reduction in air pollution levels during the

  17. Decolourization of dye-containing effluent using mineral coagulants produced by electrocoagulation.

    Science.gov (United States)

    Zidane, Fatiha; Drogui, Patrick; Lekhlif, Brahim; Bensaid, Jalila; Blais, Jean-François; Belcadi, Said; El Kacemi, Kacem

    2008-06-30

    The colour and colour causing-compounds has always been undesirable in water for any use, be it industrial or domestic wastewaters. The discharge of such effluents causes excessive oxygen demand in the receiving water and then a treatment is required before discharge into ecosystems. This study examined the possibility to remove colour causing-compounds from effluent by chemical coagulation, in comparison with direct electrocoagulation. The inorganic coagulants (C1, C2 and C3) in the form of dry powder tested, were respectively produced from electrolysis of S1=[NaOH (7.5 x 10(-3)M)], S2=[NaCl (10(-2)M)], and S3=[NaOH (7.5 x 10(-3)M)+NaCl (10(-2)M)] solutions, using sacrificial aluminium electrodes operated at an electrical potential of 12 V. Reactive textile dye (CI Reactive Red 141) was used as model of colour-causing compound prepared at a concentration of 50 mgl(-1). The best performances of dye removal were obtained with C(2) having a chemical structure comprised of a mixture of polymeric specie (Al45O45(OH)45Cl) and monomeric species (AlCl(OH)2.2H2O and Al(OH)3). The removal efficiency (R(A)) evaluated by measuring the yields of 540 nm-absorbance removal varied from 41 to 96% through 60 min of treatment by imposing a concentration of C2 ranging from 100 to 400 mg l(-1). The effectiveness of the treatment increased and the effluent became more and more transparent while increasing C(2) concentration. The comparison of chemical treatment using C2 coagulant and direct electrocoagulation of CI Reactive Red 141 containing synthetic solution demonstrated the advantage of chemical treatment during the first few minutes of treatment. A yield of 88% of absorbance removal was recorded using C2 coagulant (400 mg l(-1)) over the first 10 min of treatment, compared to 60% measured using direct electrocoagulation while imposing either 10 or 15 V of electrical potential close to the value (12 V) required during C2 production. However, at the end of the treatment (after 60

  18. Natural organic matters removal efficiency by coagulation

    Science.gov (United States)

    Sapingi, Mohd Sharizal Mohd; Pishal, Munirah; Murshed, Mohamad Fared

    2017-10-01

    The presence of Natural Organic Matter (NOM) in surface water results in unwanted characteristics in terms of color, odor, and taste. NOM content reaction with free chlorine in treated water lowers the water quality further. Chlorine is added for disinfection and produces undesirable disinfection by-products (DPBs). DBPs in drinking water are carcinogenic to consumers and may promote cancerous cell development in the human body. This study was performed to compare the coagulant efficiency of aluminum sulfate (Alum) and ferric chloride (FeCl3) on NOM removal (as in UV254 absorbance) and turbidity removal under three pH conditions (pH 6, pH 7, and sample actual pH). The three sampling points for these studies were Jalan Baru River, Kerian River, and Redac Pond. Additional sampling points, such as Lubuk Buntar and a tubewell located in the Civil Engineering School, were included to observe differences in characteristics. DOC, UV absorbance, and full wavelength were tested, after which samples treated with alum were also tested to further analyze the NOM content. Based on UV254 absorbance and DOC data, specific UV value was calculated to obtain vital synopsis of the characteristics of NOM content, as well as coagulation efficiency.

  19. Novel approach of signal normalization for depth profile of cultural heritage materials

    Science.gov (United States)

    Syvilay, D.; Detalle, V.; Wilkie-Chancellier, N.; Texier, A.; Martinez, L.; Serfaty, S.

    2017-01-01

    The investigation of cultural heritage materials is always complex and specific because unique. Materials are most often heterogeneous and organized in several layers such as mural paintings or corrosion products. The characterization of a complete artwork's stratigraphy is actually one of the questions of science conservation. Indeed, the knowledge of these layers allows completing the history of the work of art and a better understanding of alteration processes in order to set up an appropriate conservation action. The LIBS technique has been employed to study the stratigraphy of an artwork thanks to the ablation laser. However, as we know, atomic information could be insufficient to characterize two materials composed by the same based elements. Therefore, an additional molecular analysis, like Raman spectroscopy; is sometimes necessary for a better identification of the material in particular for organic coatings in cultural heritage. We suggest in this study to use Standard Normal Variate (SNV) as a common normalization for different kinds of spectra (LIBS and Raman spectroscopy) combined with a 3D colour representation for stratigraphic identification of the different layers composing the complex material from artwork. So in this investigation, the SNV method will be applied on LIBS and Raman spectra but also on baseline Raman spectra often considering as nuisance. The aim of this study is to demonstrate the versatility of SNV applied on varied spectra like LIBS, Raman spectra as well as the luminescence background. This original work considers the SNV with a 3D colour representation as a probable new perspective for an easy recognition of a structure layered with a direct overview of the depth profile of the artwork.

  20. Improving the Efficiency of a Coagulation-Flocculation Wastewater Treatment of the Semiconductor Industry through Zeta Potential Measurements

    Directory of Open Access Journals (Sweden)

    Eduardo Alberto López-Maldonado

    2014-01-01

    Full Text Available Efficiency of coagulation-flocculation process used for semiconductor wastewater treatment was improved by selecting suitable conditions (pH, polyelectrolyte type, and concentration through zeta potential measurements. Under this scenario the zeta potential, ζ, is the right parameter that allows studying and predicting the interactions at the molecular level between the contaminants in the wastewater and polyelectrolytes used for coagulation-flocculation. Additionally, this parameter is a key factor for assessing the efficiency of coagulation-flocculation processes based on the optimum dosages and windows for polyelectrolytes coagulation-flocculation effectiveness. In this paper, strategic pH variations allowed the prediction of the dosage of polyelectrolyte on wastewater from real electroplating baths, including the isoelectric point (IEP of the dispersions of water and commercial polyelectrolytes used in typical semiconductor industries. The results showed that there is a difference between polyelectrolyte demand required for the removal of suspended solids, turbidity, and organic matter from wastewater (23.4 mg/L and 67 mg/L, resp.. It was also concluded that the dose of polyelectrolytes and coagulation-flocculation window to achieve compliance with national and international regulations as EPA in USA and SEMARNAT in Mexico is influenced by the physicochemical characteristics of the dispersions and treatment conditions (pH and polyelectrolyte dosing strategy.