WorldWideScience

Sample records for nonsensory cochlear duct

  1. Hepatocyte Growth Factor-c-MET Signaling Mediates the Development of Nonsensory Structures of the Mammalian Cochlea and Hearing.

    Science.gov (United States)

    Shibata, Shumei; Miwa, Toru; Wu, Hsiao-Huei; Levitt, Pat; Ohyama, Takahiro

    2016-08-03

    The stria vascularis is a nonsensory structure that is essential for auditory hair cell function by maintaining potassium concentration of the scala media. During mouse embryonic development, a subpopulation of neural crest cell-derived melanocytes migrates and incorporates into a subregion of the cochlear epithelium, forming the intermediate cell layer of the stria vascularis. The relation of this developmental process to stria vascularis function is currently unknown. In characterizing the molecular differentiation of developing peripheral auditory structures, we discovered that hepatocyte growth factor (Hgf) is expressed in the future stria vascularis of the cochlear epithelium. Its receptor tyrosine kinase, c-Met, is expressed in the cochlear epithelium and melanocyte-derived intermediate cells in the stria vascularis. Genetic dissection of HGF signaling via c-MET reveals that the incorporation of the melanocytes into the future stria vascularis of the cochlear duct requires c-MET signaling. In addition, inactivation of either the ligand or receptor developmentally resulted in a profound hearing loss at young adult stages. These results suggest a novel connection between HGF signaling and deafness via melanocyte deficiencies. We found the roles of hepatocyte growth factor (HGF) signaling in stria vascularis development for the first time and that lack of HGF signaling in the inner ear leads to profound hearing loss in the mouse. Our findings reveal a novel mechanism that may underlie human deafness DFNB39 and DFNB97. Our findings reveal an additional example of context-dependent c-MET signaling diversity, required here for proper cellular invasion developmentally that is essential for specific aspects of auditory-related organogenesis. Copyright © 2016 the authors 0270-6474/16/368200-10$15.00/0.

  2. Hepatocyte Growth Factor–c-MET Signaling Mediates the Development of Nonsensory Structures of the Mammalian Cochlea and Hearing

    Science.gov (United States)

    Shibata, Shumei; Miwa, Toru; Wu, Hsiao-Huei; Levitt, Pat

    2016-01-01

    The stria vascularis is a nonsensory structure that is essential for auditory hair cell function by maintaining potassium concentration of the scala media. During mouse embryonic development, a subpopulation of neural crest cell-derived melanocytes migrates and incorporates into a subregion of the cochlear epithelium, forming the intermediate cell layer of the stria vascularis. The relation of this developmental process to stria vascularis function is currently unknown. In characterizing the molecular differentiation of developing peripheral auditory structures, we discovered that hepatocyte growth factor (Hgf) is expressed in the future stria vascularis of the cochlear epithelium. Its receptor tyrosine kinase, c-Met, is expressed in the cochlear epithelium and melanocyte-derived intermediate cells in the stria vascularis. Genetic dissection of HGF signaling via c-MET reveals that the incorporation of the melanocytes into the future stria vascularis of the cochlear duct requires c-MET signaling. In addition, inactivation of either the ligand or receptor developmentally resulted in a profound hearing loss at young adult stages. These results suggest a novel connection between HGF signaling and deafness via melanocyte deficiencies. SIGNIFICANCE STATEMENT We found the roles of hepatocyte growth factor (HGF) signaling in stria vascularis development for the first time and that lack of HGF signaling in the inner ear leads to profound hearing loss in the mouse. Our findings reveal a novel mechanism that may underlie human deafness DFNB39 and DFNB97. Our findings reveal an additional example of context-dependent c-MET signaling diversity, required here for proper cellular invasion developmentally that is essential for specific aspects of auditory-related organogenesis. PMID:27488639

  3. An automated A-value measurement tool for accurate cochlear duct length estimation.

    Science.gov (United States)

    Iyaniwura, John E; Elfarnawany, Mai; Ladak, Hanif M; Agrawal, Sumit K

    2018-01-22

    There has been renewed interest in the cochlear duct length (CDL) for preoperative cochlear implant electrode selection and postoperative generation of patient-specific frequency maps. The CDL can be estimated by measuring the A-value, which is defined as the length between the round window and the furthest point on the basal turn. Unfortunately, there is significant intra- and inter-observer variability when these measurements are made clinically. The objective of this study was to develop an automated A-value measurement algorithm to improve accuracy and eliminate observer variability. Clinical and micro-CT images of 20 cadaveric cochleae specimens were acquired. The micro-CT of one sample was chosen as the atlas, and A-value fiducials were placed onto that image. Image registration (rigid affine and non-rigid B-spline) was applied between the atlas and the 19 remaining clinical CT images. The registration transform was applied to the A-value fiducials, and the A-value was then automatically calculated for each specimen. High resolution micro-CT images of the same 19 specimens were used to measure the gold standard A-values for comparison against the manual and automated methods. The registration algorithm had excellent qualitative overlap between the atlas and target images. The automated method eliminated the observer variability and the systematic underestimation by experts. Manual measurement of the A-value on clinical CT had a mean error of 9.5 ± 4.3% compared to micro-CT, and this improved to an error of 2.7 ± 2.1% using the automated algorithm. Both the automated and manual methods correlated significantly with the gold standard micro-CT A-values (r = 0.70, p value measurement tool using atlas-based registration methods was successfully developed and validated. The automated method eliminated the observer variability and improved accuracy as compared to manual measurements by experts. This open-source tool has the potential to benefit

  4. A simple method for purification of vestibular hair cells and non-sensory cells, and application for proteomic analysis.

    Science.gov (United States)

    Herget, Meike; Scheibinger, Mirko; Guo, Zhaohua; Jan, Taha A; Adams, Christopher M; Cheng, Alan G; Heller, Stefan

    2013-01-01

    Mechanosensitive hair cells and supporting cells comprise the sensory epithelia of the inner ear. The paucity of both cell types has hampered molecular and cell biological studies, which often require large quantities of purified cells. Here, we report a strategy allowing the enrichment of relatively pure populations of vestibular hair cells and non-sensory cells including supporting cells. We utilized specific uptake of fluorescent styryl dyes for labeling of hair cells. Enzymatic isolation and flow cytometry was used to generate pure populations of sensory hair cells and non-sensory cells. We applied mass spectrometry to perform a qualitative high-resolution analysis of the proteomic makeup of both the hair cell and non-sensory cell populations. Our conservative analysis identified more than 600 proteins with a false discovery rate of Analysis of proteins exclusively detected in either population revealed 64 proteins that were specific to hair cells and 103 proteins that were only detectable in non-sensory cells. Statistical analyses extended these groups by 53 proteins that are strongly upregulated in hair cells versus non-sensory cells and vice versa by 68 proteins. Our results demonstrate that enzymatic dissociation of styryl dye-labeled sensory hair cells and non-sensory cells is a valid method to generate pure enough cell populations for flow cytometry and subsequent molecular analyses.

  5. Cochlear implant: what the radiologist should know

    Directory of Open Access Journals (Sweden)

    Natalia Delage Gomes

    2013-06-01

    Full Text Available Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition.

  6. Cochlear implant: what the radiologist should know

    International Nuclear Information System (INIS)

    Gomes, Natalia Delage; Couto, Caroline Laurita Batista; Gaiotti, Juliana Oggioni; Costa, Ana Maria Doffemond; Ribeiro, Marcelo Almeida; Diniz, Renata Lopes Furletti Caldeira

    2013-01-01

    Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition. (author)

  7. Continued expression of GATA3 is necessary for cochlear neurosensory development.

    Directory of Open Access Journals (Sweden)

    Jeremy S Duncan

    Full Text Available Hair cells of the developing mammalian inner ear are progressively defined through cell fate restriction. This process culminates in the expression of the bHLH transcription factor Atoh1, which is necessary for differentiation of hair cells, but not for their specification. Loss of several genes will disrupt ear morphogenesis or arrest of neurosensory epithelia development. We previously showed in null mutants that the loss of the transcription factor, Gata3, results specifically in the loss of all cochlear neurosensory development. Temporal expression of Gata3 is broad from the otic placode stage through the postnatal ear. It therefore remains unclear at which stage in development Gata3 exerts its effect. To better understand the stage specific effects of Gata3, we investigated the role of Gata3 in cochlear neurosensory specification and differentiation utilizing a LoxP targeted Gata3 line and two Cre lines. Foxg1(Cre∶Gata3(f/f mice show recombination of Gata3 around E8.5 but continue to develop a cochlear duct without differentiated hair cells and spiral ganglion neurons. qRT-PCR data show that Atoh1 was down-regulated but not absent in the duct whereas other hair cell specific genes such as Pou4f3 were completely absent. In addition, while Sox2 levels were lower in the Foxg1(Cre:Gata3(f/f cochlea, Eya1 levels remained normal. We conclude that Eya1 is unable to fully upregulate Atoh1 or Pou4f3, and drive differentiation of hair cells without Gata3. Pax2-Cre∶Gata3(f/f mice show a delayed recombination of Gata3 in the ear relative to Foxg1(Cre:Gata3(f/f . These mice exhibited a cochlear duct containing patches of partially differentiated hair cells and developed only few and incorrectly projecting spiral ganglion neurons. Our conditional deletion studies reveal a major role of Gata3 in the signaling of prosensory genes and in the differentiation of cochlear neurosenory cells. We suggest that Gata3 may act in combination with Eya1, Six1, and

  8. Variations in U.S. Consumers' Acceptability of Korean Rice Cake, Seolgitteok, with respect to Sensory Attributes and Nonsensory Factors.

    Science.gov (United States)

    Cho, Sungeun; Yoon, Suk Hoo; Min, Jieun; Lee, Suji; Tokar, Tonya; Lee, Sun-Ok; Seo, Han-Seok

    2016-01-01

    Because the Korean rice cake, Seolgitteok, is mainly prepared with rice flour containing no gluten-protein associated with celiac disease, it can be considered for inclusion in a gluten-free diet. However, Western consumers may be unlikely to enjoy the plain flavor and chewy texture of Seolgitteok. This study aimed to determine both sensory and nonsensory factors that might affect U.S. consumers' acceptability of Seolgitteok. A total of 119 U.S. consumers rated 5 Seolgitteok samples, differentiated by descriptive sensory analysis, with respect to hedonic impression and just-about-right aspects of sensory attributes. Nonsensory factors such as demographic profile, innovativeness, social representation, sensation-seeking, and personality traits were also assessed. Addition levels of brown rice flour (0% to 100%) and sugar (5% to 20%) not only enriched flavor, but also lessened chewiness of Seolgitteok, thereby increasing an overall hedonic impression. Moreover, consumer acceptability of Seolgitteok varied with respect to nonsensory factors. Seolgitteok was more appreciated by males, sensation seekers, and individuals constrained by social desirability than by other groups. In conclusion, these findings demonstrate that U.S. consumers' acceptability of Seolgitteok varies not only by sensory attributes such as rice flavor, sweetness, and chewiness, but also by nonsensory factors such as gender, sensation-seeking characteristics, and personality traits. © 2015 Institute of Food Technologists®

  9. Hearing loss in fibromyalgia? Somatic sensory and non-sensory symptoms in patients with fibromyalgia and other rheumatic disorders

    NARCIS (Netherlands)

    Wolfe, Frederick; Rasker, Johannes J.; Häuser, W.

    2012-01-01

    OBJECTIVES: It has been proposed that fibromyalgia can be understood as a disorder of central sensitisation and dysregulation (CD) and that characteristic somatic symptoms are the result of `central augmentation`. We examined this hypothesis by analysing sensory and non-sensory variables in the

  10. Cochlear implant: what the radiologist should know; Implante coclear: o que o radiologista precisa saber

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Natalia Delage; Couto, Caroline Laurita Batista; Gaiotti, Juliana Oggioni; Costa, Ana Maria Doffemond; Ribeiro, Marcelo Almeida; Diniz, Renata Lopes Furletti Caldeira, E-mail: nataliadelagegomes@gmail.com [Hospital Mater Dei, Belo Horizonte, MG (Brazil). Unidade de Radiologia e Diagnostico por Imagem

    2013-05-15

    Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition. (author)

  11. Generation of induced neurons by direct reprogramming in the mammalian cochlea.

    Science.gov (United States)

    Nishimura, K; Weichert, R M; Liu, W; Davis, R L; Dabdoub, A

    2014-09-05

    Primary auditory neurons (ANs) in the mammalian cochlea play a critical role in hearing as they transmit auditory information in the form of electrical signals from mechanosensory cochlear hair cells in the inner ear to the brainstem. Their progressive degeneration is associated with disease conditions, excessive noise exposure and aging. Replacement of ANs, which lack the ability to regenerate spontaneously, would have a significant impact on research and advancement in cochlear implants in addition to the amelioration of hearing impairment. The aim of this study was to induce a neuronal phenotype in endogenous non-neural cells in the cochlea, which is the essential organ of hearing. Overexpression of a neurogenic basic helix-loop-helix transcription factor, Ascl1, in the cochlear non-sensory epithelial cells induced neurons at high efficiency at embryonic, postnatal and juvenile stages. Moreover, induced neurons showed typical properties of neuron morphology, gene expression and electrophysiology. Our data indicate that Ascl1 alone or Ascl1 and NeuroD1 is sufficient to reprogram cochlear non-sensory epithelial cells into functional neurons. Generation of neurons from non-neural cells in the cochlea is an important step for the regeneration of ANs in the mature mammalian cochlea. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.

  12. Cochlear implantation in patients with bilateral cochlear trauma.

    Science.gov (United States)

    Serin, Gediz Murat; Derinsu, Ufuk; Sari, Murat; Gergin, Ozgül; Ciprut, Ayça; Akdaş, Ferda; Batman, Cağlar

    2010-01-01

    Temporal bone fracture, which involves the otic capsule, can lead to complete loss of auditory and vestibular functions, whereas the patients without fractures may experience profound sensorineural hearing loss due to cochlear concussion. Cochlear implant is indicated in profound sensorineural hearing loss due to cochlear trauma but who still have an intact auditory nerve. This is a retrospective review study. We report 5 cases of postlingually deafened patients caused by cochlear trauma, who underwent cochlear implantation. Preoperative and postoperative hearing performance will be presented. These patients are cochlear implanted after the cochlear trauma in our department between 2001 and 2006. All patients performed very well with their implants, obtained open-set speech understanding. They all became good telephone users after implantation. Their performance in speech understanding was comparable to standard postlingual adult patients implanted. Cochlear implantation is an effective aural rehabilitation in profound sensorineural hearing loss caused by temporal bone trauma. Preoperative temporal bone computed tomography, magnetic resonance imaging, and promontorium stimulation testing are necessary to make decision for the surgery and to determine the side to be implanted. Surgery could be challenging and complicated because of anatomical irregularity. Moreover, fibrosis and partial or total ossification within the cochlea must be expected. Copyright 2010. Published by Elsevier Inc.

  13. Relationship of the area measurement of the large endolymphatic duct and sac syndrome as well as the clinical symptoms with CT and MR imaging results

    International Nuclear Information System (INIS)

    Park, Ji Sang; Hong, Hyun Sook; Lee, Jong Sea; Kim, Dae Ho; Lee, Hae Kyung; Yi, Beom Ha; Cha, Jang Gyu; Park, Seong Jin; Kim, Shi Chan

    2008-01-01

    To evaluate the CT and MRI findings of the large endolymphatic duct or sac syndrome (LEDS) and its associated anomalies, with clinical features. We retrospectively reviewed the MR and CT images of 52 ears obtained from 26 patients with LEDS. We reviewed the clinical findings, audiology testing, and treatment results. The degree of hearing loss was classified from normal to profound, based on pure tone audiometry. The largest areas were measured at each endolymphatic duct and analyzed to determine whether a correlation exists with the degree of hearing loss. We also analyzed the differences in measurements between CT and MRI findings. All 26 patients had some degree of sensorineural hearing loss, which resulted in 18 ears to undergo a cochlear implantation. One patient was diagnosed with Cornelia de Lange syndrome. Five patients had a sudden hearing loss onset. Ten ears had incomplete cochlear partitions, whereas 28 ears had enlarged vestibules. All patients had severe to profound hearing loss. We found no statistical correlation between the size of the largest area of the endolymphatic duct and the degree of hearing loss. The mean area of the endolymphatic ducts, as per an MRI examination, revealed slightly greater areas than the CT findings, although the differences were not significant. Enlarged vestibules and incomplete partitions of the cochlea were common anomalies associated with LEDS. We found no statistical correlation between the largest area of the endolymphatic duct or sac with the degree of hearing loss

  14. Effect of cochlear nerve electrocautery on the adult cochlear nucleus.

    Science.gov (United States)

    Iseli, Claire E; Merwin, William H; Klatt-Cromwell, Cristine; Hutson, Kendall A; Ewend, Matthew G; Adunka, Oliver F; Fitzpatrick, Douglas C; Buchman, Craig A

    2015-04-01

    Electrocauterization and subsequent transection of the cochlear nerve induce greater injury to the cochlear nucleus than sharp transection alone. Some studies show that neurofibromatosis Type 2 (NF2) patients fit with auditory brainstem implants (ABIs) fail to achieve speech perception abilities similar to ABI recipients without NF2. Reasons for these differences remain speculative. One hypothesis posits poorer performance to surgically induced trauma to the cochlear nucleus from electrocautery. Sustained electrosurgical depolarization of the cochlear nerve may cause excitotoxic-induced postsynaptic nuclear injury. Equally plausible is that cautery in the vicinity of the cochlear nucleus induces necrosis. The cochlear nerve was transected in anesthetized adult gerbils sharply with or without bipolar electrocautery at varying intensities. Gerbils were perfused at 1, 3, 5, and 7 days postoperatively; their brainstem and cochleas were embedded in paraffin and sectioned at 10 μm. Alternate sections were stained with flourescent markers for neuronal injury or Nissl substance. In additional experiments, anterograde tracers were applied directly to a sectioned eighth nerve to verify that fluorescent-labeled profiles seen were terminating auditory nerve fibers. Cochlear nerve injury was observed from 72 hours postoperatively and was identical across cases regardless of surgical technique. Postsynaptic cochlear nucleus injury was not seen after distal transection of the nerve. By contrast, proximal transection was associated with trauma to the cochlear nucleus. Distal application of bipolar electrocautery seems safe for the cochlear nucleus. Application near the root entry zone must be used cautiously because this may compromise nuclear viability needed to support ABI stimulation.

  15. Fluid coupling in a discrete model of cochlear mechanics.

    Science.gov (United States)

    Elliott, Stephen J; Lineton, Ben; Ni, Guangjian

    2011-09-01

    A discrete model of cochlear mechanics is introduced that includes a full, three-dimensional, description of fluid coupling. This formulation allows the fluid coupling and basilar membrane dynamics to be analyzed separately and then coupled together with a simple piece of linear algebra. The fluid coupling is initially analyzed using a wavenumber formulation and is separated into one component due to one-dimensional fluid coupling and one comprising all the other contributions. Using the theory of acoustic waves in a duct, however, these two components of the pressure can also be associated with a far field, due to the plane wave, and a near field, due to the evanescent, higher order, modes. The near field components are then seen as one of a number of sources of additional longitudinal coupling in the cochlea. The effects of non-uniformity and asymmetry in the fluid chamber areas can also be taken into account, to predict both the pressure difference between the chambers and the mean pressure. This allows the calculation, for example, of the effect of a short cochlear implant on the coupled response of the cochlea. © 2011 Acoustical Society of America

  16. Communication between cochlear perilymph and cerebrospinal fluid through the cochlear modiolus visualized after intratympanic administration of Gd-DTPA

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Satake, Hiroko; Iwano, Shingo; Sone, Michihiko; Nakashima, Tsutomu

    2008-01-01

    Intratympanic injection of gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) has been reported as a procedure to visualize endolymphatic hydrops of Meniere's disease. We frequently noted that cerebrospinal fluid (CSF) in the internal auditory canal (IAC) was also enhanced after this procedure. The purpose of this study was to evaluate how frequently this occurs and to investigate the specific features of patients who lack this communication. A total of 25 patients with clinically suspected endolymphatic hydrops underwent the procedure. After 24 h, three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) and 3D constructive interference in steady state (3D-CISS) were performed. The presence of contrast enhancement in the CSF space of the fundus of the IAC was evaluated. The contrast ratio between CSF of the IAC fundus and cerebellar white matter on the injected side was 1.49±0.65, and that of the noninjected side was 0.32±0.16 (P<0.01). Enhancement of the CSF space in the IAC fundus was seen in all but two subjects: one had enlarged endolymphatic duct and sac syndrome (EEDS), and the other had cochlear nerve agenesis. In these two patients, the cochlear modiolus seemed to be normal. Intratympanic Gd-DTPA administration can reveal permeability of the modiolus and might facilitate evaluation of functional abnormalities of the modiolus not detected by conventional imaging tests. (author)

  17. Diversity in cochlear morphology and its influence on cochlear implant electrode position

    NARCIS (Netherlands)

    Marel, K.S. van der; Briaire, J.J.; Wolterbeek, R..; Snel-Bongers, J.; Verbist, B.M.; Frijns, J.H.

    2014-01-01

    To define a minimal set of descriptive parameters for cochlear morphology and study its influence on the cochlear implant electrode position in relation to surgical insertion distance.Cochlear morphology and electrode position were analyzed using multiplanar reconstructions of the pre- and

  18. The impact of duct-to-duct interaction on the hex duct dilation

    International Nuclear Information System (INIS)

    Lee, M.J.; Chang, L.K.; Lahm, C.E.; Porter, D.L.

    1992-01-01

    Dilation of the hex duct is an important factor in the operational lifetime of fuel subassemblies in liquid metal fast reactors. It is caused primarily by the irradiation-enhanced creep and void swelling of the hex duct material. Excessive dilation may jeopardize subassembly removal from the core or cause a subassembly storage problem where the grid size of the storage basket is limited. Dilation of the hex duct in Experimental Breeder Reactor II (EBR-II) limits useful lifetime because of these storage basket limitations. It is, therefore, important to understand the hex duct dilation behavior to guide the design and in-core management of fuel subassemblies in a way that excessive duct deformation can be avoided. To investigate the dilation phenomena, finite-element models of the hex duct have been developed. The inelastic analyses were performed using the structural analysis code, ANSYS. Both Type 316 and D9 austenitic stainless steel ducts are considered. The calculated dilations are in good agreement with profilometry measurements made after irradiation. The analysis indicates that subassembly interaction is an important parameter in addition to neutron fluence and temperature in determining hex duct dilation. 5 refs

  19. Bioinformatic Integration of Molecular Networks and Major Pathways Involved in Mice Cochlear and Vestibular Supporting Cells.

    Science.gov (United States)

    Requena, Teresa; Gallego-Martinez, Alvaro; Lopez-Escamez, Jose A

    2018-01-01

    Background : Cochlear and vestibular epithelial non-hair cells (ENHCs) are the supporting elements of the cellular architecture in the organ of Corti and the vestibular neuroepithelium in the inner ear. Intercellular and cell-extracellular matrix interactions are essential to prevent an abnormal ion redistribution leading to hearing and vestibular loss. The aim of this study is to define the main pathways and molecular networks in the mouse ENHCs. Methods : We retrieved microarray and RNA-seq datasets from mouse epithelial sensory and non-sensory cells from gEAR portal (http://umgear.org/index.html) and obtained gene expression fold-change between ENHCs and non-epithelial cells (NECs) against HCs for each gene. Differentially expressed genes (DEG) with a log2 fold change between 1 and -1 were discarded. The remaining genes were selected to search for interactions using Ingenuity Pathway Analysis and STRING platform. Specific molecular networks for ENHCs in the cochlea and the vestibular organs were generated and significant pathways were identified. Results : Between 1723 and 1559 DEG were found in the mouse cochlear and vestibular tissues, respectively. Six main pathways showed enrichment in the supporting cells in both tissues: (1) "Inhibition of Matrix Metalloproteases"; (2) "Calcium Transport I"; (3) "Calcium Signaling"; (4) "Leukocyte Extravasation Signaling"; (5) "Signaling by Rho Family GTPases"; and (6) "Axonal Guidance Si". In the mouse cochlea, ENHCs showed a significant enrichment in 18 pathways highlighting "axonal guidance signaling (AGS)" ( p = 4.37 × 10 -8 ) and "RhoGDI Signaling" ( p = 3.31 × 10 -8 ). In the vestibular dataset, there were 20 enriched pathways in ENHCs, the most significant being "Leukocyte Extravasation Signaling" ( p = 8.71 × 10 -6 ), "Signaling by Rho Family GTPases" ( p = 1.20 × 10 -5 ) and "Calcium Signaling" ( p = 1.20 × 10 -5 ). Among the top ranked networks, the most biologically significant network contained the

  20. Benefits and Risks of Cochlear Implants

    Science.gov (United States)

    ... and Medical Procedures Implants and Prosthetics Cochlear Implants Benefits and Risks of Cochlear Implants Share Tweet Linkedin ... the Use of Cochlear Implants What are the Benefits of Cochlear Implants? For people with implants: Hearing ...

  1. Assessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography

    OpenAIRE

    Dalbert, Adrian; Pfiffner, Flurin; Hoesli, Marco; Koka, Kanthaiah; Veraguth, Dorothe; Roosli, Christof; Huber, Alexander

    2018-01-01

    Objective: The aims of this study were: (1) To investigate the correlation between electrophysiological changes during cochlear implantation and postoperative hearing loss, and (2) to detect the time points that electrophysiological changes occur during cochlear implantation. Material and Methods: Extra- and intracochlear electrocochleography (ECoG) were used to detect electrophysiological changes during cochlear implantation. Extracochlear ECoG recordings were conducted through a needle elec...

  2. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  3. Direct measurement of cerebrospinal fluid pressure through the cochlea in a congenitally deaf child with Mondini dysplasia undergoing cochlear implantation.

    Science.gov (United States)

    Graham, J M; Ashcroft, P

    1999-03-01

    Perilymph/cerebrospinal fluid (CSF) "gushers" may occur at cochleostomy during cochlear implant surgery, particularly in patients with congenital cochlear duct malformation in which CSF in the internal auditory meatus is in direct communication with the perilymphatic space in the cochlea. The object of the study was to measure the pressure and flow of a CSF gusher at cochleostomy. The design was a preoperative pressure measurement. The setting was a multidisciplinary cochlear implant program. A 4-year-old girl with bilateral Mondini deformity undergoing cochlear implantation was studied. A size 23 FG intravenous cannula was inserted into the cochlea and connected to a pediatric drip set to form an improvised manometer. Intracochlear fluid pressure was measured at 14 cm H2O, equivalent to the normal CSF pressure that would be recorded in a child of this age at lumbar puncture. An indirect measurement of the likely size of the CSF/perilymph defect was made. This technique may allow better assessment of the risk of postoperative CSF leakage and meningitis. This simple technique of measuring the pressure in a perilymph gusher can be used to assess the need for careful sealing of the cochleostomy, to measure the reduction in pressure produced by head elevation or a spinal drain, and to assess the probable size of a defect in the lamina cribrosa.

  4. Congenitally Deafblind Children and Cochlear Implants

    DEFF Research Database (Denmark)

    Dammeyer, Jesper Herup

    2008-01-01

    There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on cochlear implantation in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of 5 congenitally...... deafblind children who received cochlear implants between 2.2 and 4.2 years of age.  Ratings of video observations were used to measure the children's early communication development with and without the use of their cochlear implants. In addition, parental interviews were used to assess the benefits...... parents perceived regarding their children's cochlear implants. Two examples are included in this article to illustrate the parents' perspectives about cochlear implantation in their deafblind children. Benefits of cochlear implantation in this cohort of children included improved attention and emotional...

  5. Characterization of Cochlear, Vestibular and Cochlear-Vestibular Electrically Evoked Compound Action Potentials in Patients with a Vestibulo-Cochlear Implant

    Directory of Open Access Journals (Sweden)

    T. A. K. Nguyen

    2017-11-01

    Full Text Available The peripheral vestibular system is critical for the execution of activities of daily life as it provides movement and orientation information to motor and sensory systems. Patients with bilateral vestibular hypofunction experience a significant decrease in quality of life and have currently no viable treatment option. Vestibular implants could eventually restore vestibular function. Most vestibular implant prototypes to date are modified cochlear implants to fast-track development. These use various objective measurements, such as the electrically evoked compound action potential (eCAP, to supplement behavioral information. We investigated whether eCAPs could be recorded in patients with a vestibulo-cochlear implant. Specifically, eCAPs were successfully recorded for cochlear and vestibular setups, as well as for mixed cochlear-vestibular setups. Similarities and slight differences were found for the recordings of the three setups. These findings demonstrated the feasibility of eCAP recording with a vestibulo-cochlear implant. They could be used in the short term to reduce current spread and avoid activation of non-targeted neurons. More research is warranted to better understand the neural origin of vestibular eCAPs and to utilize them for clinical applications.

  6. Retrolabyrinthine approach for cochlear nerve preservation in neurofibromatosis type 2 and simultaneous cochlear implantation

    Directory of Open Access Journals (Sweden)

    Bento, Ricardo Ferreira

    2014-01-01

    Full Text Available Introduction: Few cases of cochlear implantation (CI in neurofibromatosis type 2 (NF2 patients had been reported in the literature. The approaches described were translabyrinthine, retrosigmoid or middle cranial fossa. Objectives: To describe a case of a NF2- deafened-patient who underwent to vestibular schwannoma resection via RLA with cochlear nerve preservation and CI through the round window, at the same surgical time. Resumed Report: A 36-year-old woman with severe bilateral hearing loss due to NF2 was submitted to vestibular schwannoma resection and simultaneous CI. Functional assessment of cochlear nerve was performed by electrical promontory stimulation. Complete tumor removal was accomplishment via RLA with anatomic and functional cochlear and facial nerve preservation. Cochlear electrode array was partially inserted via round window. Sound field hearing threshold improvement was achieved. Mean tonal threshold was 46.2 dB HL. The patient could only detect environmental sounds and human voice but cannot discriminate vowels, words nor do sentences at 2 years of follow-up. Conclusion: Cochlear implantation is a feasible auditory restoration option in NF2 when cochlear anatomic and functional nerve preservation is achieved. The RLA is adequate for this purpose and features as an option for hearing preservation in NF2 patients.

  7. Focused tight dressing does not prevent cochlear implant magnet migration under 1.5 Tesla MRI.

    Science.gov (United States)

    Cuda, D; Murri, A; Succo, G

    2013-04-01

    We report a retrospective case of inner magnet migration, which occurred after 1.5 Tesla MRI scanning in an adult recipient of a bilateral cochlear implant (CI) despite a focused head dressing. The patient, bilaterally implanted with Nucleus 5 CIs (Cochlear LTD, Sydney, Australia), underwent a 1.5 Tesla cholangio-MRI scan for biliary duct pathology. In subsequent days, a focal skin alteration appeared over the left inner coil. Plain skull radiographs showed partial magnet migration on the left side. Surgical exploration confirmed magnet twisting; the magnet was effectively repositioned. Left CI performance was restored to pre-migration level. The wound healed without complications. Thus, focused dressing does not prevent magnet migration in CI recipients undergoing 1.5 Tesla MRI. All patients should be counselled on this potential complication. A minor surgical procedure is required to reposition the magnet. Nevertheless, timely diagnosis is necessary to prevent skin breakdown and subsequent device contamination. Plain skull radiograph is very effective in identifying magnet twisting; it should be performed systematically after MRI or minimally on all suspected cases.

  8. Cochlear implant revision surgeries in children.

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2018-02-16

    The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  9. Sox10 expressing cells in the lateral wall of the aged mouse and human cochlea.

    Directory of Open Access Journals (Sweden)

    Xinping Hao

    Full Text Available Age-related hearing loss (presbycusis is a common human disorder, affecting one in three Americans aged 60 and over. Previous studies have shown that presbyacusis is associated with a loss of non-sensory cells in the cochlear lateral wall. Sox10 is a transcription factor crucial to the development and maintenance of neural crest-derived cells including some non-sensory cell types in the cochlea. Mutations of the Sox10 gene are known to cause various combinations of hearing loss and pigmentation defects in humans. This study investigated the potential relationship between Sox10 gene expression and pathological changes in the cochlear lateral wall of aged CBA/CaJ mice and human temporal bones from older donors. Cochlear tissues prepared from young adult (1-3 month-old and aged (2-2.5 year-old mice, and human temporal bone donors were examined using quantitative immunohistochemical analysis and transmission electron microscopy. Cells expressing Sox10 were present in the stria vascularis, outer sulcus and spiral prominence in mouse and human cochleas. The Sox10(+ cell types included marginal and intermediate cells and outer sulcus cells, including those that border the scala media and those extending into root processes (root cells in the spiral ligament. Quantitative analysis of immunostaining revealed a significant decrease in the number of Sox10(+ marginal cells and outer sulcus cells in aged mice. Electron microscopic evaluation revealed degenerative alterations in the surviving Sox10(+ cells in aged mice. Strial marginal cells in human cochleas from donors aged 87 and older showed only weak immunostaining for Sox10. Decreases in Sox10 expression levels and a loss of Sox10(+ cells in both mouse and human aged ears suggests an important role of Sox10 in the maintenance of structural and functional integrity of the lateral wall. A loss of Sox10(+ cells may also be associated with a decline in the repair capabilities of non-sensory cells in the

  10. Cochlear implantation in Mondini dysplasia.

    Science.gov (United States)

    Daneshi, Ahmad; Hassanzadeh, Saeid; Abasalipour, Parvaneh; Emamdjomeh, Hessamaddin; Farhadi, Mohammad

    2003-01-01

    The use of cochlear implantation to treat patients with inner ear malformations such as Mondini dysplasia has been increasingly successful. Until now, conventional hearing aids in these patients have not performed well. Consequently, the hearing problem for patients with this condition has been somewhat improved with the use of cochlear implants. Various results of cochlear implantation have been reported in these patients so far. This is a report of 5 patients with Mondini malformation who have undergone cochlear implant surgery. Copyright 2003 S. Karger AG, Basel

  11. [Morphologic feature and cochlear implant surgical approach for cochlear modiolus deficiency].

    Science.gov (United States)

    Zhang, Daoxing

    2014-09-01

    To review the classification of cochlear modiolus deficiency and decision on surgical approach for above case,in order to provide mastery for cochlear implant (CI) indication. Basing on temporal bone HRCT pre-operation, CI subjects with modiolus deficiency were defined as following groups: (1) deficiency caused by cochlear dysplasia (Mondini malformation); (2) deficiency caused by dysplasia of cochlear and vestibule (Common cavity malformation); (3) deficiency caused by absence of internal acoustic meatus fundus (IP-III malformation). Three types of surgical approach were utilized: type I, electrode array was introduced through facial recess, enlarged the round window, type II, opened the surface of chchlea, electrode array was introduced through facial recess, fenestration on posterior promontory and then inserted around lateral wall of inner-cochlear cavity. type III, electrode array was introduce through fenestration of lateral semicircular canal and then placed close to the bony wall of common cavity. One hundred and sixty-six cochlear modiolus deficiency cases were identified into 3 groups as following: 135 Mondini malformation cases into group a, 18 common cavity malformation cases into group b, and 13 IP-III malformation cases into group c. Surgical approach: type I were used in 136 cases (123 Mondini cases and 13 IP-III cases), while approach type II in 12 cases (12 Mondini cases), and approach type III in 18 cases (18 common cavity cases). Income post-operation of CI: For group a (Mondini malformation), post-activation mean hearing threshold in sound field was 65 dB, speech recognition score is 95% (single finals test) and 25% (signal initials test), while it was 80 dB, 60% and 0 for group b (Conmon cavity malformation), and it was 55 dB, 100% and 45% for group c (IP-III malformation). The income of speech recognition score for cochlear modiolus deficiency was relatively poor, group b was worst and group c was best, while group a moderate.

  12. COCHLEAR IMPLANTATION PREVALENCE IN ELDERLY

    Directory of Open Access Journals (Sweden)

    A. V. Starokha

    2014-01-01

    Full Text Available Current paper describes an experience of cochlear implantation in elderly. Cochlear implantation has become a widely accepted intervention in the treatment of individuals with severe-to-profound sensorineural hearing loss. Cochlear implants are now accepted as a standard of care to optimize hearing and subsequent speech development in children and adults with deafness. But cochlear implantation affects not only hearing abilities, speech perception and speech production; it also has an outstanding impact on the social life, activities and self-esteem of each patient. The aim of this study was to evaluate the cochlear implantation efficacy in elderly with severe to profound sensorineural hearing loss. There were 5 patients under our observation. Surgery was performed according to traditional posterior tympanotomy and cochleostomy for cochlear implant electrode insertion for all observed patients. The study was conducted in two stages: before speech processor’s activation and 3 months later. Pure tone free field audiometry was performed to each patient to assess the efficiency of cochlear implantation in dynamics. The aim of the study was also to evaluate quality of life in elderly with severe to profound sensorineural hearing loss after unilateral cochlear implantation. Each patient underwent questioning with 36 Item Short Form Health Survey (SF-36. SF-36 is a set of generic, coherent, and easily administered quality-of-life measures. The SF-36 consists of eight scaled scores, which are the weighted sums of the questions in their section. Each scale is directly transformed into a 0-100 scale on the assumption that each question carries equal weight. The eight sections are: physical functioning; physical role functioning; emotional role functioning; vitality; emotional well-being; social role functioning; bodily pain; general health perceptions. Our results demonstrate that cochlear implantation in elderly consistently improved quality of life

  13. Bile Duct Exploration

    Science.gov (United States)

    ... Home / Health Library / Diagnostics & Testing / Bile Duct Exploration Bile Duct Exploration Common bile duct exploration is a ... Test Details Results and Follow-Up What is bile, and what is bile duct exploration? Bile is ...

  14. Cochlear implants in Waardenburg syndrome.

    Science.gov (United States)

    Cullen, Robert D; Zdanski, Carlton; Roush, Patricia; Brown, Carolyn; Teagle, Holly; Pillsbury, Harold C; Buchman, Craig

    2006-07-01

    Waardenburg syndrome is an autosomal-dominant syndrome characterized by dystopia canthorum, hyperplasia of the eyebrows, heterochromia irides, a white forelock, and sensorineural hearing loss in 20% to 55% of patients. This patient population accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with Waardenburg syndrome who have undergone cochlear implantation. Pediatric cochlear implant recipients with documented evidence of Waardenburg syndrome underwent retrospective case review. All patients received their cochlear implants at the study institution followed by outpatient auditory habilitation. Charts were reviewed for etiology and duration of deafness, age at time of cochlear implantation, perioperative complications, duration of use, and performance outcomes. Results of standard tests batteries for speech perception and production administered as a part of the patients' auditory habilitation were reviewed. Seven patients with Waardenburg syndrome and cochlear implants were identified. The average age at implantation was 37 months (range, 18-64 months) and the average duration of use was 69 months (range, 12-143 months). All of these patients are active users of their devices and perform very well after implantation. There were no major complications in this small group of patients. Children with congenital sensorineural hearing loss without other comorbidities (e.g., developmental delay, inner ear malformations) perform well when they receive cochlear implantation and auditory habilitation. Patients with Waardenburg syndrome can be expected to have above-average performance after cochlear implantation.

  15. CT evaluation of preoperative cochlear implantation cochlear implantation

    International Nuclear Information System (INIS)

    Tan Xiuzhong; Zhong Lansheng; Lan Bowen; Huang Yaosheng; Du Baowen; Zhu Jian

    2004-01-01

    Objective: To evaluate CT scan as a preoperative evaluation for cochlear implantation candidates. Methods: Axial high-resolution temporal bone CT and three-dimensional reconstruction of inner ear were performed in 93 patients with sensorineural hearing loss. results: Among 81 patients with congenital sensorineural deafness, Mondini malformation was seen in 7 case (13 ears); large vestibular aqueduct syndrome (LVAS) was revealed in 5 cases (8 ears); and inner ear ossification was found in 1 case (2 ears). In 1 case (2 ears) of inner ear fibrosis, reduced cochlear signal was noted on MRI but no unremarkable findings was shown on CT scan, however, in the operation, the device could not inserted into the basal circle of the cochlea, due to fibrous obliteration. In 12 patients with post-speech deafness, chronic suppurative tympanitis was seen in 2 cases (4 ears), and inner ear ossification was revealed in 1 case (2 ears). Conclusion: CT plays an indispensable role in the pre-operative evaluation of cochlear implantation. T 2 -weighted FSE-MRI of the inner ear is a useful complementary to CT scan. (authors)

  16. Serotonin projection patterns to the cochlear nucleus.

    Science.gov (United States)

    Thompson, A M; Thompson, G C

    2001-07-13

    The cochlear nucleus is well known as an obligatory relay center for primary auditory nerve fibers. Perhaps not so well known is the neural input to the cochlear nucleus from cells containing serotonin that reside near the midline in the midbrain raphe region. Although the specific locations of the main, if not sole, sources of serotonin within the dorsal cochlear nucleus subdivision are known to be the dorsal and median raphe nuclei, sources of serotonin located within other cochlear nucleus subdivisions are not currently known. Anterograde tract tracing was used to label fibers originating from the dorsal and median raphe nuclei while fluorescence immunohistochemistry was used to simultaneously label specific serotonin fibers in cat. Biotinylated dextran amine was injected into the dorsal and median raphe nuclei and was visualized with Texas Red, while serotonin was visualized with fluorescein. Thus, double-labeled fibers were unequivocally identified as serotoninergic and originating from one of the labeled neurons within the dorsal and median raphe nuclei. Double-labeled fiber segments, typically of fine caliber with oval varicosities, were observed in many areas of the cochlear nucleus. They were found in the molecular layer of the dorsal cochlear nucleus, in the small cell cap region, and in the granule cell and external regions of the cochlear nuclei, bilaterally, of all cats. However, the density of these double-labeled fiber segments varied considerably depending upon the exact region in which they were found. Fiber segments were most dense in the dorsal cochlear nucleus (especially in the molecular layer) and the large spherical cell area of the anteroventral cochlear nucleus; they were moderately dense in the small cell cap region; and fiber segments were least dense in the octopus and multipolar cell regions of the posteroventral cochlear nucleus. Because of the presence of labeled fiber segments in subdivisions of the cochlear nucleus other than the

  17. Follow-up of cochlear implant use in patients who developed bacterial meningitis following cochlear implantation.

    Science.gov (United States)

    Mancini, Patrizia; D'Elia, Chiara; Bosco, Ersilia; De Seta, Elio; Panebianco, Valeria; Vergari, Valeria; Filipo, Roberto

    2008-08-01

    The present study is a long-term follow-up of speech perception outcomes and cochlear implant use in three cases of meningitis that occurred after cochlear implantation. Case series study. Study was performed on three children implanted with different models of Clarion devices, two of them with positioner. Recognition and comprehension were assessed via the Italian adaptation of GASP (TAP) test, and phonetically balanced bi-syllabic words in open-set. High resolution computed tomography scan acquisition was performed to obtain axial coronal and oblique multiplanar reconstructions of the cochlea. Two patients were affected by enlarged cochlear acqueduct and Mondini malformation the first carrying positioner. One patient had a normal cochlea, and the positioner could have been the main cause of bacterial spread. As a consequence of meningitis the child with normal cochlea and the other with enlarged vestibular acqueduct developed cochlear ossification, increased M-level and worsening of hearing outcomes. The child with Mondini malformation developed facial nerve stimulation. Contralateral implantation was performed in the first two patients. Bacterial meningitis occurring after cochlear implantation may induce cochlear ossification, facial nerve stimulation, and permanent or temporary loss of implant use. Planned follow-up with high resolution computed tomography and evaluation of M-levels could be useful prognostic tools in the management of these patients.

  18. Audiovisual segregation in cochlear implant users.

    Directory of Open Access Journals (Sweden)

    Simon Landry

    Full Text Available It has traditionally been assumed that cochlear implant users de facto perform atypically in audiovisual tasks. However, a recent study that combined an auditory task with visual distractors suggests that only those cochlear implant users that are not proficient at recognizing speech sounds might show abnormal audiovisual interactions. The present study aims at reinforcing this notion by investigating the audiovisual segregation abilities of cochlear implant users in a visual task with auditory distractors. Speechreading was assessed in two groups of cochlear implant users (proficient and non-proficient at sound recognition, as well as in normal controls. A visual speech recognition task (i.e. speechreading was administered either in silence or in combination with three types of auditory distractors: i noise ii reverse speech sound and iii non-altered speech sound. Cochlear implant users proficient at speech recognition performed like normal controls in all conditions, whereas non-proficient users showed significantly different audiovisual segregation patterns in both speech conditions. These results confirm that normal-like audiovisual segregation is possible in highly skilled cochlear implant users and, consequently, that proficient and non-proficient CI users cannot be lumped into a single group. This important feature must be taken into account in further studies of audiovisual interactions in cochlear implant users.

  19. Reactive neurogenesis and down-regulation of the potassium-chloride cotransporter KCC2 in the cochlear nuclei after cochlear deafferentation

    Directory of Open Access Journals (Sweden)

    Brahim Tighilet

    2016-08-01

    Full Text Available While many studies have been devoted to investigating the homeostatic plasticity triggered by cochlear hearing loss, the cellular and molecular mechanisms involved in these central changes remain elusive. In the present study, we investigated the possibility of reactive neurogenesis after unilateral cochlear nerve section in the cochlear nucleus of cats. We found a strong cell proliferation in all the cochlear nucleus sub-divisions ipsilateral to the lesion. Most of the newly generated cells survive up to one month after cochlear deafferentation in all cochlear nuclei (except the dorsal cochlear nucleus and give rise to a variety of cell types, i.e. microglial cells, astrocytes and neurons. Interestingly, many of the newborn neurons had an inhibitory (GABAergic phenotype. This result is intriguing since sensory deafferentation is usually accompanied by enhanced excitation, consistent with a reduction in central inhibition. The membrane potential effect of GABA depends, however, on the intra-cellular chloride concentration, which is maintained at low levels in adults by the potassium chloride co-transporter KCC2. The KCC2 density on the plasma membrane of neurons was then assessed after cochlear deafferentation in the cochlear nuclei ipsilateral and contralateral to the lesion. Cochlear deafferentation is accompanied by a strong down-regulation of KCC2 ipsilateral to the lesion at 3 and 30 days post-lesion. This study suggests that reactive neurogenesis and downregulation of KCC2 is part of the vast repertoire involved in homeostatic plasticity triggered by hearing loss. These central changes may also play a role in the generation of tinnitus and hyperacusis.

  20. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction systems ducts and air duct systems. 29.1103 Section 29.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Induction System § 29.1103 Induction systems ducts and air duct...

  1. Cochlear implants and medical tourism.

    Science.gov (United States)

    McKinnon, Brian J; Bhatt, Nishant

    2010-09-01

    To compare the costs of medical tourism in cochlear implant surgery performed in India as compared to the United States. In addition, the cost savings of obtaining cochlear implant surgery in India were compare d to those of other surgical interventions obtained as a medical tourist. Searches were conducted on Medline and Google using the search terms: 'medical tourism', 'medical offshoring', 'medical outsourcing', 'cochlear implants' and 'cochlear implantation'. The information regarding cost of medical treatment was obtained from personal communication with individuals familiar with India's cochlear implantation medical tourism industry. The range of cost depended on length of stay as well as the device chosen. Generally the cost, inclusive of travel, surgery and device, was in the range of $21,000-30,000, as compared to a cost range of $40,000-$60,000 in the US. With the escalating cost of healthcare in the United States, it is not surprising that some patients would seek to obtain surgical care overseas at a fraction of the cost. Participants in medical tourism often have financial resources, but lack health insurance coverage. While cardiovascular and orthopedic surgery performed outside the United States in India at centers that cater to medical tourists are often performed at one-quarter to one-third of the cost that would have been paid in the United States, the cost differential for cochlear implants is not nearly as favorable.

  2. Limits on normal cochlear 'third' windows provided by previous investigations of additional sound paths into and out of the cat inner ear.

    Science.gov (United States)

    Rosowski, John J; Bowers, Peter; Nakajima, Hideko H

    2018-03-01

    While most models of cochlear function assume the presence of only two windows into the mammalian cochlea (the oval and round windows), a position that is generally supported by several lines of data, there is evidence for additional sound paths into and out of the inner ear in normal mammals. In this report we review the existing evidence for and against the 'two-window' hypothesis. We then determine how existing data and inner-ear anatomy restrict transmission of sound through these additional sound pathways in cat by utilizing a well-tested model of the cat inner ear, together with anatomical descriptions of the cat cochlear and vestibular aqueducts (potential additional windows to the cochlea). We conclude: (1) The existing data place limits on the size of the cochlear and vestibular aqueducts in cat and are consistent with small volume-velocities through these ducts during ossicular stimulation of the cochlea, (2) the predicted volume velocities produced by aqueducts with diameters half the size of the bony diameters match the functional data within ±10 dB, and (3) these additional volume velocity paths contribute to the inner ear's response to non-acoustic stimulation and conductive pathology. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Parental expectations and outcomes of pediatric cochlear implantation.

    Science.gov (United States)

    Piazza, Elizabeth; Kandathil, Cherian; Carron, Jeffrey D

    2009-10-01

    Cochlear implants have been used with increasing frequency over the past twenty years, including very young patients. To determine if parents are satisfied with their children's performance after cochlear implantation. Survey mailed to parents of children receiving cochlear implants. 31 questionnaires were returned out of 69 mailed (45 %). The vast majority of responding parents felt that their children benefited substantially from cochlear implant surgery. Cochlear implantation is effective in helping children develop auditory-oral communication skills. Access to auditory/oral communication programs in this state remains an obstacle in postoperative habilitation.

  4. Importance of cochlear health for implant function.

    Science.gov (United States)

    Pfingst, Bryan E; Zhou, Ning; Colesa, Deborah J; Watts, Melissa M; Strahl, Stefan B; Garadat, Soha N; Schvartz-Leyzac, Kara C; Budenz, Cameron L; Raphael, Yehoash; Zwolan, Teresa A

    2015-04-01

    Amazing progress has been made in providing useful hearing to hearing-impaired individuals using cochlear implants, but challenges remain. One such challenge is understanding the effects of partial degeneration of the auditory nerve, the target of cochlear implant stimulation. Here we review studies from our human and animal laboratories aimed at characterizing the health of the implanted cochlea and the auditory nerve. We use the data on cochlear and neural health to guide rehabilitation strategies. The data also motivate the development of tissue-engineering procedures to preserve or build a healthy cochlea and improve performance obtained by cochlear implant recipients or eventually replace the need for a cochlear implant. This article is part of a Special Issue entitled . Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Evaluation of the usefulness of three-dimensional optical coherence tomography in a guinea pig model of endolymphatic hydrops induced by surgical obliteration of the endolymphatic duct

    Science.gov (United States)

    Cho, Nam Hyun; Lee, Jang Woo; Cho, Jin-ho; Kim, Jeehyun; Jang, Jeong Hun; Jung, Woonggyu

    2015-03-01

    Optical coherence tomography (OCT) has advanced significantly over the past two decades and is currently used extensively to monitor the internal structures of organs, particularly in ophthalmology and dermatology. We used ethylenediamine tetra-acetic acid (EDTA) to decalcify the bony walls of the cochlea and investigated the inner structures by deep penetration of light into the cochlear tissue using OCT on a guinea pig model of endolymphatic hydrops (EH), induced by surgical obliteration of the endolymphatic duct. The structural and functional changes associated with EH were identified using OCT and auditory brainstem response tests, respectively. We also evaluated structural alterations in the cochlea using three-dimensional reconstruction of the OCT images, which clearly showed physical changes in the cochlear structures. Furthermore, we found significant anatomical variations in the EH model and conducted graphical analysis by strial atrophy for comparison. The physical changes included damage to and flattening of the organ of Corti-evidence of Reissner's membrane distention-and thinning of the lateral wall. These results indicate that observation of EDTA-decalcified cochlea using OCT is significant in examination of gradual changes in the cochlear structures that are otherwise not depicted by hematoxylin and eosin staining.

  6. The cochlear nerve canal and internal auditory canal in children with normal cochlea but cochlear nerve deficiency

    International Nuclear Information System (INIS)

    Yan, Fei; Li, Jianhong; Xian, Junfang; Wang, Zhenchang; Mo, Lingyan

    2013-01-01

    Background: There is an increasing frequency of requests for cochlear implantation (CI) in deaf children and more detailed image information is necessary for selecting appropriate candidates. Cochlear nerve deficiency (CND) is a contraindication to CI. Magnetic resonance imaging (MRI) has been used to evaluate the integrity of the cochlear nerve. The abnormalities of the cochlear nerve canal (CNC) and internal auditory canal (IAC) have been reported to be associated with CND. Purpose: To correlate CNC manifestation, size, and IAC diameter on high-resolution CT (HRCT) with CND diagnosed by MRI in children. Material and Methods: HRCT images from 35 sensorineurally deaf children who had normal cochlea but bilateral or unilateral CND diagnosed by MRI were studied retrospectively. The CNC and IAC manifestation and size were assessed and correlated with CND. Results: CND was diagnosed by MRI in 54/70 ears (77.1%). Thirty-two ears had an absent cochlear nerve (59.3%), while 22 ears had a small cochlear nerve (40.7%). The CNC diameter was 2.0 mm in 11 ears (20.4%). The IAC diameter was 3.0 mm in 29 ears (53.7%). Conclusion: The hypoplastic CNC might be more highly indicative of CND than that of a narrow IAC

  7. [Cochlear implantation through the middle fossa approach].

    Science.gov (United States)

    Szyfter, W; Colletti, V; Pruszewicz, A; Kopeć, T; Szymiec, E; Kawczyński, M; Karlik, M

    2001-01-01

    The inner part of cochlear implant is inserted into inner ear during surgery through mastoid and middle ear. It is a classical method, used in the majority cochlear centers in the world. This is not a suitable method in case of chronic otitis media and middle ear malformation. In these cases Colletti proposed the middle fossa approach and cochlear implant insertion omitting middle ear structures. In patient with bilateral chronic otitis media underwent a few ears operations without obtaining dry postoperative cavity. Cochlear implantation through the middle fossa approach was performed in this patient. The bone fenster was cut, temporal lobe was bent and petrosus pyramid upper surface was exposed. When the superficial petrosal greater nerve, facial nerve and arcuate eminence were localised, the cochlear was open in the basal turn and electrode were inserted. The patient achieves good results in the postoperative speech rehabilitation. It confirmed Colletti tesis that deeper electrode insertion in the cochlear implantation through the middle fossa approach enable use of low and middle frequencies, which are very important in speech understanding.

  8. [Multi-channel cochlear implants in patients with Mondini malformation].

    Science.gov (United States)

    Li, Yong-xin; Han, De-min; Zhao, Xiao-tian; Chen, Xue-qing; Kong, Ying; Zheng, Jun; Liu, Bo; Liu, Sha; Mo, Ling-yan; Zhang, Hua; Wang, Shuo

    2004-02-01

    To describe clinical experiences with multi-channel cochlear implantation in patients with Mondini malformation. Among 300 patients who received multi-channel cochlear implants from 1996 to 2002 in Beijing Tongren Hospital, 15 patients were diagnosed with Mondini malformation. A retrospective analysis was performed dealing with the surgical techniques, mapping and rehabilitations characteristics after surgery. 15 patients with normal cochlear structure are consider as control group. Gusher is found more common than the normal cochlear implantation, most of them are serious. The electrodes are inserted in the "cochleostomy" in full length of 13 Patients, 2 pairs of electrodes remains outside of "cochleostomy" in 2 patients. No serious complications occurred after implantation. All patients have auditory sensations. The impedance of the electrodes, the T level, C level and the hearing threshold are similar with the normal cochlear implantation group. The results have no significant difference in compare with normal cochlear group(P > 0.05). Multi-channel cochlear implantation could be performed safely in patients with Mondini malformation. The primary outcome for patients with Mondini malformation are similar to those with normal cochlear structure following the multi-channel cochlear implantation.

  9. Transcystic duct treatment of common bile duct stones

    International Nuclear Information System (INIS)

    Amberg, J.R.; Chun, G.

    1981-01-01

    Successful removal of 2 retained common bile duct stones following cholecystostomy is described. With the use of the steerable catheter and the wire basket, one stone was crushed and the second was extracted in retrograde fashion through the cystic duct and gallbladder. (orig.)

  10. Rare bile duct anomaly: B3 duct draining to gallbladder

    Directory of Open Access Journals (Sweden)

    Seung Eun Lee

    2016-01-01

    Full Text Available A 10-year-old girl presented with recurrent right upper abdominal pain and dyspepsia. Magnetic resonance cholangiopancreatography revealed a dilated common channel of intrahepatic bile duct of segment 3 (B3 and segment 4 (B4 drained into the gallbladder directly. The patient underwent laparoscopic cholecystectomy and Roux-en Y hepaticojejunostomy (B3-jejunostomy. Among the anatomical variability of the biliary system, the cholecystohepatic ducts are controversial in existence and incidence. We report a very rare variant of a cholecystohepatic duct in which the B3 duct drained into gallbladder directly and to the best of our knowledge this is the first report.

  11. Cochlear implantation in a bilateral Mondini dysplasia.

    Science.gov (United States)

    Turrini, M; Orzan, E; Gabana, M; Genovese, E; Arslan, E; Fisch, U

    1997-01-01

    We report the speech perception progress and programming procedures of a case of congenital profound deafness and bilateral Mondini dysplasia implanted with a Nucleus 20 + 2 cochlear implant at the age of six. Unclear relations between electrodes array and cochlear partition made implant programming difficult and non-standard procedures were set. Cochlear implantation may give excellent rehabilitative results also in cochleae with malformation.

  12. Particle deposition in ventilation ducts

    Energy Technology Data Exchange (ETDEWEB)

    Sippola, Mark Raymond [Univ. of California, Berkeley, CA (United States)

    2002-09-01

    Exposure to airborne particles is detrimental to human health and indoor exposures dominate total exposures for most people. The accidental or intentional release of aerosolized chemical and biological agents within or near a building can lead to exposures of building occupants to hazardous agents and costly building remediation. Particle deposition in heating, ventilation and air-conditioning (HVAC) systems may significantly influence exposures to particles indoors, diminish HVAC performance and lead to secondary pollutant release within buildings. This dissertation advances the understanding of particle behavior in HVAC systems and the fates of indoor particles by means of experiments and modeling. Laboratory experiments were conducted to quantify particle deposition rates in horizontal ventilation ducts using real HVAC materials. Particle deposition experiments were conducted in steel and internally insulated ducts at air speeds typically found in ventilation ducts, 2-9 m/s. Behaviors of monodisperse particles with diameters in the size range 1-16 μm were investigated. Deposition rates were measured in straight ducts with a fully developed turbulent flow profile, straight ducts with a developing turbulent flow profile, in duct bends and at S-connector pieces located at duct junctions. In straight ducts with fully developed turbulence, experiments showed deposition rates to be highest at duct floors, intermediate at duct walls, and lowest at duct ceilings. Deposition rates to a given surface increased with an increase in particle size or air speed. Deposition was much higher in internally insulated ducts than in uninsulated steel ducts. In most cases, deposition in straight ducts with developing turbulence, in duct bends and at S-connectors at duct junctions was higher than in straight ducts with fully developed turbulence. Measured deposition rates were generally higher than predicted by published models. A model incorporating empirical equations based on the

  13. Curved-Duct

    Directory of Open Access Journals (Sweden)

    Je Hyun Baekt

    2000-01-01

    Full Text Available A numerical study is conducted on the fully-developed laminar flow of an incompressible viscous fluid in a square duct rotating about a perpendicular axis to the axial direction of the duct. At the straight duct, the rotation produces vortices due to the Coriolis force. Generally two vortex cells are formed and the axial velocity distribution is distorted by the effect of this Coriolis force. When a convective force is weak, two counter-rotating vortices are shown with a quasi-parabolic axial velocity profile for weak rotation rates. As the rotation rate increases, the axial velocity on the vertical centreline of the duct begins to flatten and the location of vorticity center is moved near to wall by the effect of the Coriolis force. When the convective inertia force is strong, a double-vortex secondary flow appears in the transverse planes of the duct for weak rotation rates but as the speed of rotation increases the secondary flow is shown to split into an asymmetric configuration of four counter-rotating vortices. If the rotation rates are increased further, the secondary flow restabilizes to a slightly asymmetric double-vortex configuration. Also, a numerical study is conducted on the laminar flow of an incompressible viscous fluid in a 90°-bend square duct that rotates about axis parallel to the axial direction of the inlet. At a 90°-bend square duct, the feature of flow by the effect of a Coriolis force and a centrifugal force, namely a secondary flow by the centrifugal force in the curved region and the Coriolis force in the downstream region, is shown since the centrifugal force in curved region and the Coriolis force in downstream region are dominant respectively.

  14. Bile Duct Cancer (Cholangiocarcinoma)

    Science.gov (United States)

    ... Home > Types of Cancer > Bile Duct Cancer (Cholangiocarcinoma) Bile Duct Cancer (Cholangiocarcinoma) This is Cancer.Net’s Guide to Bile Duct Cancer (Cholangiocarcinoma). Use the menu below to ...

  15. Trends in Cochlear Implants

    OpenAIRE

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic as...

  16. Developing flow in S-shaped ducts. 2: Circular cross-section duct

    Science.gov (United States)

    Taylor, A. M. K. P.; Whitelaw, J. H.; Yianneskis, M.

    1984-01-01

    Laser-Doppler velocimetry measured the laminar and turbulent streamwise flow in a S-duct. The wall pressure distribution and one component of cross-stream velocity were also obtained for the turbulent flow case. Boundary layers near the duct inlet were about 25 percent of the hydraulic diameter in the laminar flow and varied around the periphery of the pipe between 10 percent and 20 percent in turbulent flow. Pressure-driven secondary flows develop in the first half of the S-duct and are attenuated and reversed in the second half. For both Reynolds numbers there is a region near the outer wall of the second half of the duct where the sign of the radial vorticity results in an enforcement of the secondary flow which was established in the first half of the S-duct. The core flow migrates, for both Reynolds numbers, to the outside wall of the first half and lies towards the inside wall of the second half of the S-duct at the outlet. The thinner inlet boundary layers in the turbulent flow give rise to weaker secondary motion.

  17. What Does Music Sound Like for a Cochlear Implant User?

    Science.gov (United States)

    Jiam, Nicole T; Caldwell, Meredith T; Limb, Charles J

    2017-09-01

    Cochlear implant research and product development over the past 40 years have been heavily focused on speech comprehension with little emphasis on music listening and enjoyment. The relatively little understanding of how music sounds in a cochlear implant user stands in stark contrast to the overall degree of importance the public places on music and quality of life. The purpose of this article is to describe what music sounds like to cochlear implant users, using a combination of existing research studies and listener descriptions. We examined the published literature on music perception in cochlear implant users, particularly postlingual cochlear implant users, with an emphasis on the primary elements of music and recorded music. Additionally, we administered an informal survey to cochlear implant users to gather first-hand descriptions of music listening experience and satisfaction from the cochlear implant population. Limitations in cochlear implant technology lead to a music listening experience that is significantly distorted compared with that of normal hearing listeners. On the basis of many studies and sources, we describe how music is frequently perceived as out-of-tune, dissonant, indistinct, emotionless, and weak in bass frequencies, especially for postlingual cochlear implant users-which may in part explain why music enjoyment and participation levels are lower after implantation. Additionally, cochlear implant users report difficulty in specific musical contexts based on factors including but not limited to genre, presence of lyrics, timbres (woodwinds, brass, instrument families), and complexity of the perceived music. Future research and cochlear implant development should target these areas as parameters for improvement in cochlear implant-mediated music perception.

  18. [The development of musicality in children after cochlear implantation].

    Science.gov (United States)

    Zheng, Yan; Liu, Bo; Dong, Ruijuan; Xu, Tianqiu; Chen, Jing; Chen, Xuejing; Zhong, Yan; Meng, Chao; Wang, Hong; Chen, Xueqing

    2014-08-01

    The purpose of this study is to analyze the development of musicality in children after cochlear implantation, and provide a clinical database for the evaluation of their musicality. Twenty-six children with cochlear implants (CI group) participated in this research. They received cochlear implants at the age of 11 to 68 months with a mean of 35.6 months. Seventy-six infants as a control group aged from 1 to 24 months with a mean of 6.1 months participated in this study, whose hearing were considered normal by passing the case history collection, high-risk registers for hearing loss and hearing screening using DPOAE. The music and young children with CIs: Musicality Rating Scale was used to evaluate their musicality. The evaluation was performed before cochlear implantation and 1, 3, 6, 9, 12, 24 months after cochlear implantation for children with cochlear implants. The evaluation was also performed at 1, 3, 6, 9, 12, 24 months for children with normal hearing. The mean scores of musicality showed significant improvements with time of CI use for CI group (Pmusicality also showed significant improvements with time for control group (P0.05). Significant difference was noted between the two groups at 24 months (Pmusicality of children with cochlear implants improved significantly with time after cochlear implantation. The most rapid growth was found in the first year after cochlear implantation.

  19. The cochlear nerve canal and internal auditory canal in children with normal cochlea but cochlear nerve deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Fei; Li, Jianhong; Xian, Junfang; Wang, Zhenchang [Dept. of Radiology, Beijing Tongren Hospital, Capital Medical Univ., Beijing (China)], e-mail: cjr.wzhch@vip.163.com; Mo, Lingyan [Dept. of Otorhinolaryngology, Beijing Tongren Hospital, Capital Medical Univ., Beijing (China)

    2013-04-15

    Background: There is an increasing frequency of requests for cochlear implantation (CI) in deaf children and more detailed image information is necessary for selecting appropriate candidates. Cochlear nerve deficiency (CND) is a contraindication to CI. Magnetic resonance imaging (MRI) has been used to evaluate the integrity of the cochlear nerve. The abnormalities of the cochlear nerve canal (CNC) and internal auditory canal (IAC) have been reported to be associated with CND. Purpose: To correlate CNC manifestation, size, and IAC diameter on high-resolution CT (HRCT) with CND diagnosed by MRI in children. Material and Methods: HRCT images from 35 sensorineurally deaf children who had normal cochlea but bilateral or unilateral CND diagnosed by MRI were studied retrospectively. The CNC and IAC manifestation and size were assessed and correlated with CND. Results: CND was diagnosed by MRI in 54/70 ears (77.1%). Thirty-two ears had an absent cochlear nerve (59.3%), while 22 ears had a small cochlear nerve (40.7%). The CNC diameter was <1.5 mm in 36 ears (66.7%). The CNC diameter ranged between 1.5 and 2.0 mm in seven ears (13.0%) and was >2.0 mm in 11 ears (20.4%). The IAC diameter was <3.0 mm in 25 ears (46.3%) and >3.0 mm in 29 ears (53.7%). Conclusion: The hypoplastic CNC might be more highly indicative of CND than that of a narrow IAC.

  20. New Criteria of Indication and Selection of Patients to Cochlear Implant

    Directory of Open Access Journals (Sweden)

    André L. L. Sampaio

    2011-01-01

    Full Text Available Numerous changes continue to occur in cochlear implant candidacy. In general, these have been accompanied by concomitant and satisfactory changes in surgical techniques. Together, this has advanced the utility and safety of cochlear implantation. Most devices are now approved for use in patients with severe to profound unilateral hearing loss rather then the prior requirement of a bilateral profound loss. Furthermore, studies have begun utilizing short electrode arrays for shallow insertion in patients with considerable low-frequency residual hearing. This technique will allow the recipient to continue to use acoustically amplified hearing for the low frequencies simultaneously with a cochlear implant for the high frequencies. The advances in design of, and indications for, cochlear implants have been matched by improvements in surgical techniques and decrease in complications. The resulting improvements in safety and efficacy have further encouraged the use of these devices. This paper will review the new concepts in the candidacy of cochlear implant. Medline data base was used to search articles dealing with the following topics: cochlear implant in younger children, cochlear implant and hearing preservation, cochlear implant for unilateral deafness and tinnitus, genetic hearing loss and cochlear implant, bilateral cochlear implant, neuropathy and cochlear implant and neural plasticity, and the selection of patients for cochlear implant.

  1. Remote programming of cochlear implants: a telecommunications model.

    Science.gov (United States)

    McElveen, John T; Blackburn, Erin L; Green, J Douglas; McLear, Patrick W; Thimsen, Donald J; Wilson, Blake S

    2010-09-01

    Evaluate the effectiveness of remote programming for cochlear implants. Retrospective review of the cochlear implant performance for patients who had undergone mapping and programming of their cochlear implant via remote connection through the Internet. Postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for 7 patients who had undergone remote mapping and programming of their cochlear implant were compared with the mean scores of 7 patients who had been programmed by the same audiologist over a 12-month period. Times required for remote and direct programming were also compared. The quality of the Internet connection was assessed using standardized measures. Remote programming was performed via a virtual private network with a separate software program used for video and audio linkage. All 7 patients were programmed successfully via remote connectivity. No untoward patient experiences were encountered. No statistically significant differences could be found in comparing postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for patients who had undergone remote programming versus a similar group of patients who had their cochlear implant programmed directly. Remote programming did not require a significantly longer programming time for the audiologist with these 7 patients. Remote programming of a cochlear implant can be performed safely without any deterioration in the quality of the programming. This ability to remotely program cochlear implant patients gives the potential to extend cochlear implantation to underserved areas in the United States and elsewhere.

  2. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  3. Intraoperative cochlear nerve mapping with the mobile cochlear nerve compound action potential tracer in vestibular schwannoma surgery.

    Science.gov (United States)

    Watanabe, Nobuyuki; Ishii, Takuya; Fujitsu, Kazuhiko; Kaku, Shogo; Ichikawa, Teruo; Miyahara, Kosuke; Okada, Tomu; Tanino, Shin; Uriu, Yasuhiro; Murayama, Yuichi

    2018-05-18

    OBJECTIVE The authors describe the usefulness and limitations of the cochlear nerve compound action potential (CNAP) mobile tracer (MCT) that they developed to aid in cochlear nerve mapping during vestibular schwannoma surgery (VSS) for hearing preservation. METHODS This MCT device requires no more than 2 seconds for stable placement on the nerve to obtain the CNAP and thus is able to trace the cochlear nerve instantaneously. Simultaneous bipolar and monopolar recording is possible. The authors present the outcomes of 18 consecutive patients who underwent preoperative useful hearing (defined as class I or II of the Gardner-Robertson classification system) and underwent hearing-preservation VSS with the use of the MCT. Mapping was considered successful when it was possible to detect and trace the cochlear nerve. RESULTS Mapping of the cochlear nerve was successful in 13 of 18 patients (72.2%), and useful hearing was preserved in 11 patients (61.1%). Among 8 patients with large tumors (Koos grade 3 or 4), the rate of successful mapping was 62.5% (5 patients). The rate of hearing preservation in patients with large tumors was 50% (4 patients). CONCLUSIONS In addition to microsurgical presumption of the arrangement of each nerve, frequent probing on and around an unidentified nerve and comparison of each waveform are advisable with the use of both more sensitive monopolar and more location-specific bipolar MCT. MCT proved to be useful in cochlear nerve mapping and may consequently be helpful in hearing preservation. The authors discuss some limitations and problems with this device.

  4. [Cochlear implant treatment in Germany].

    Science.gov (United States)

    Jacob, R; Stelzig, Y

    2013-01-01

    Restoration of impaired auditory function through cochlear implant is possible, with high reliably and great success. Nevertheless, there are regular disputes between patients and insurance companies due to high costs. In Germany, approx. 1.9 Mio. people are severely hearing impaired. It can be estimated that for adequate hearing rehabilitation about 30,000 cochlear implants/year are necessary. Currently, less than 10% of those affected are offered cochlear implant. A handicap is defined if there is deviation from normal hearing for more than 6 months. This sets a time frame for the supply with cochlear implant after sudden deafness. The professional code requires to advice all medical options to a person seeking help for hearing loss. This includes benefit-risk consideration. At this point, the economic aspect plays no role. The indication for medical treatment is only subject to the treating physician and should not be modified by non-physicians or organizations. It should be noted that a supply of hearing aids is qualitatively different to the help from a cochlear implant, which provides a restoration of lost function. In social law (SGB V and IX) doctors are requested to advise and recommend all measures which contribute to normal hearing (both sides). This indicates that doctors may be prosecuted for not offering help when medically possible, just because health insurance employees did not approve the cost balance. The current situation, with insufficient medical care for the hearing impaired, needs clarifying. To do this, patients, health insurance companies, the political institutions, legislation and professional societies need to accept their responsibilities.

  5. Deafblind People's Experiences of Cochlear Implantation

    Science.gov (United States)

    Soper, Janet

    2006-01-01

    Cochlear implants are electronic devices that create the sensation of hearing in those who cannot obtain any benefit from conventional hearing aids. This article examines the experience of cochlear implantation in a select group of individuals with acquired deafblindness, focusing on three key themes: access to communication, information and…

  6. [Cochlear implantation in patients with Waardenburg syndrome type II].

    Science.gov (United States)

    Wan, Liangcai; Guo, Menghe; Chen, Shuaijun; Liu, Shuangriu; Chen, Hao; Gong, Jian

    2010-05-01

    To describe the multi-channel cochlear implantation in patients with Waardenburg syndrome including surgeries, pre and postoperative hearing assessments as well as outcomes of speech recognition. Multi-channel cochlear implantation surgeries have been performed in 12 cases with Waardenburg syndrome type II in our department from 2000 to 2008. All the patients received multi-channel cochlear implantation through transmastoid facial recess approach. The postoperative outcomes of 12 cases were compared with 12 cases with no inner ear malformation as a control group. The electrodes were totally inserted into the cochlear successfully, there was no facial paralysis and cerebrospinal fluid leakage occurred after operation. The hearing threshold in this series were similar to that of the normal cochlear implantation. After more than half a year of speech rehabilitation, the abilities of speech discrimination and spoken language of all the patients were improved compared with that of preoperation. Multi-channel cochlear implantation could be performed in the cases with Waardenburg syndrome, preoperative hearing and images assessments should be done.

  7. Propagation of sound waves in ducts

    DEFF Research Database (Denmark)

    Jacobsen, Finn

    2000-01-01

    Plane wave propagation in ducts with rigid walls, radiation from ducts, classical four-pole theory for composite duct systems, and three-dimentional waves in wave guides of various cross-sectional shape are described.......Plane wave propagation in ducts with rigid walls, radiation from ducts, classical four-pole theory for composite duct systems, and three-dimentional waves in wave guides of various cross-sectional shape are described....

  8. In Vivo Interplay between p27Kip1, GATA3, ATOH1, and POU4F3 Converts Non-sensory Cells to Hair Cells in Adult Mice

    Directory of Open Access Journals (Sweden)

    Bradley J. Walters

    2017-04-01

    Full Text Available Summary: Hearing loss is widespread and persistent because mature mammalian auditory hair cells (HCs are nonregenerative. In mice, the ability to regenerate HCs from surrounding supporting cells (SCs declines abruptly after postnatal maturation. We find that combining p27Kip1 deletion with ectopic ATOH1 expression surmounts this age-related decline, leading to conversion of SCs to HCs in mature mouse cochleae and after noise damage. p27Kip1 deletion, independent of canonical effects on Rb-family proteins, upregulated GATA3, a co-factor for ATOH1 that is lost from SCs with age. Co-activation of GATA3 or POU4F3 and ATOH1 promoted conversion of SCs to HCs in adult mice. Activation of POU4F3 alone also converted mature SCs to HCs in vivo. These data illuminate a genetic pathway that initiates auditory HC regeneration and suggest p27Kip1, GATA3, and POU4F3 as additional therapeutic targets for ATOH1-mediated HC regeneration. : Auditory hair cells are nonregenerative, resulting in persistent hearing loss upon damage. Walters et al. find that manipulating two genes, p27Kip1 and Atoh1, induces the conversion of nonsensory cells to hair cells in adult mice. This effect is mediated by GATA3 and POU4F3, where POU4F3 alone was found to convert nonsensory cells. Keywords: regeneration, aging, differentiation, proliferation, development, cancer, sensory, cochlea, hearing

  9. Duct-to-duct biliary reconstruction after radical resection of Bismuth IIIa hilar cholangiocarcinoma.

    Science.gov (United States)

    Wu, Wen-Guang; Gu, Jun; Dong, Ping; Lu, Jian-Hua; Li, Mao-Lan; Wu, Xiang-Song; Yang, Jia-Hua; Zhang, Lin; Ding, Qi-Chen; Weng, Hao; Ding, Qian; Liu, Ying-Bin

    2013-04-21

    At present, radical resection remains the only effective treatment for patients with hilar cholangiocarcinoma. The surgical approach for R0 resection of hilar cholangiocarcinoma is complex and diverse, but for the biliary reconstruction after resection, almost all surgeons use Roux-en-Y hepaticojejunostomy. A viable alternative to Roux-en-Y reconstruction after radical resection of hilar cholangiocarcinoma has not yet been proposed. We report a case of performing duct-to-duct biliary reconstruction after radical resection of Bismuth IIIa hilar cholangiocarcinoma. End-to-end anastomosis between the left hepatic duct and the distal common bile duct was used for the biliary reconstruction, and a single-layer continuous suture was performed along the bile duct using 5-0 prolene. The patient was discharged favorably without biliary fistula 2 wk later. Evidence for tumor recurrence was not found after an 18 mo follow-up. Performing bile duct end-to-end anastomosis in hilar cholangiocarcinoma can simplify the complex digestive tract reconstruction process.

  10. Chronic Conductive Hearing Loss Leads to Cochlear Degeneration.

    Science.gov (United States)

    Liberman, M Charles; Liberman, Leslie D; Maison, Stéphane F

    2015-01-01

    Synapses between cochlear nerve terminals and hair cells are the most vulnerable elements in the inner ear in both noise-induced and age-related hearing loss, and this neuropathy is exacerbated in the absence of efferent feedback from the olivocochlear bundle. If age-related loss is dominated by a lifetime of exposure to environmental sounds, reduction of acoustic drive to the inner ear might improve cochlear preservation throughout life. To test this, we removed the tympanic membrane unilaterally in one group of young adult mice, removed the olivocochlear bundle in another group and compared their cochlear function and innervation to age-matched controls one year later. Results showed that tympanic membrane removal, and the associated threshold elevation, was counterproductive: cochlear efferent innervation was dramatically reduced, especially the lateral olivocochlear terminals to the inner hair cell area, and there was a corresponding reduction in the number of cochlear nerve synapses. This loss led to a decrease in the amplitude of the suprathreshold cochlear neural responses. Similar results were seen in two cases with conductive hearing loss due to chronic otitis media. Outer hair cell death was increased only in ears lacking medial olivocochlear innervation following olivocochlear bundle cuts. Results suggest the novel ideas that 1) the olivocochlear efferent pathway has a dramatic use-dependent plasticity even in the adult ear and 2) a component of the lingering auditory processing disorder seen in humans after persistent middle-ear infections is cochlear in origin.

  11. Efter cochlear implant

    DEFF Research Database (Denmark)

    Højen, Anders

    Dit barn har netop fået et cochlear implant. Hvad nu? Skal barnet fokusere udelukkende på at lære talt sprog, eller skal det også lære/fortsætte med tegnsprog eller støttetegn? Det er et vanskeligt spørgsmål, og før valget foretages, er det vigtigt at vurdere hvilke konsekvenser valget har, dels...... for den sproglige udvikling isoleret set, og dels for barnets udvikling ud fra en helhedsbetragtning. Dette indlæg fokuserer på, hvilke forventninger man kan have til cochlear implant-brugeres sproglige udvikling med talt sprog alene, hhv. med to sprog (tale og tegn). Disse forventninger er baseret på...

  12. Reciprocity principle in duct acoustics

    Science.gov (United States)

    Cho, Y.-C.

    1979-01-01

    Various reciprocity relations in duct acoustics have been derived on the basis of the spatial reciprocity principle implied in Green's functions for linear waves. The derivation includes the reciprocity relations between mode conversion coefficients for reflection and transmission in nonuniform ducts, and the relation between the radiation of a mode from an arbitrarily terminated duct and the absorption of an externally incident plane wave by the duct. Such relations are well defined as long as the systems remain linear, regardless of acoustic properties of duct nonuniformities which cause the mode conversions.

  13. Evaluating cochlear implant trauma to the scala vestibuli.

    Science.gov (United States)

    Adunka, O; Kiefer, J; Unkelbach, M H; Radeloff, A; Gstoettner, W

    2005-04-01

    Placement of cochlear implant electrodes into the scala vestibuli may be intentional, e.g. in case of blocked scala tympani or unintentional as a result of trauma to the basilar membrane or erroneous location of the cochieostomy. The aim of this study was to evaluate the morphological consequences and cochlear trauma after implantation of different cochlear implant electrode arrays in the scala vestibuli. Human temporal bone study with histological and radiological evaluation. Twelve human cadaver temporal bones were implanted with different cochlear implant electrodes. Implanted bones were processed using a special method to section undecalcified bone. Cochlear trauma and intracochlear positions. All implanted electrodes were implanted into the scala vestibuli using a special approach that allows direct scala vestibuli insertions. Fractures of the osseous spiral lamina were evaluated in some bones in the basal cochlear regions. In most electrodes, delicate structures of the organ of Corti were left intact, however, Reissner's membrane was destroyed in all specimens and the electrode lay upon the tectorial membrane. In some bones the organ of Corti was destroyed. Scala vestibuli insertions did not cause severe trauma to osseous or neural structures, thus preserving the basis for electrostimulation of the cochlea. However, destruction of Reissner's membrane and impact on the Organ of Corti can be assumed to destroy residual hearing.

  14. Reference values of MRI measurements of the common bile duct and pancreatic duct in children

    Energy Technology Data Exchange (ETDEWEB)

    Gwal, Kriti; Bedoya, Maria A.; Patel, Neal; Darge, Kassa; Anupindi, Sudha A. [University of Pennsylvania Perelman School of Medicine, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Rambhatla, Siri J. [Beth Israel Medical Center, Department of Pediatrics, Newark, NJ (United States); Sreedharan, Ram R. [University of Pennsylvania, Departments of Gastroenterology, Hepatology and Nutrition, The Children' s Hospital of Philadelphia, Perelman School of Medicine, Philadelphia, PA (United States)

    2015-08-15

    Magnetic resonance imaging/cholangiopancreatography (MRI/MRCP) is now an essential imaging modality for the evaluation of biliary and pancreatic pathology in children, but there are no data depicting the normal diameters of the common bile duct (CBD) and pancreatic duct. Recognition of abnormal duct size is important and the increasing use of MRCP necessitates normal MRI measurements. To present normal MRI measurements for the common bile duct and pancreatic duct in children. In this retrospective study we searched all children ages birth to 10 years in our MR urography (MRU) database from 2006 until 2013. We excluded children with a history of hepatobiliary or pancreatic surgery. We stratified 204 children into five age groups and retrospectively measured the CBD and the pancreatic duct on 2-D axial and 3-D coronal T2-weighted sequences. We performed statistical analysis, using logistic and linear regressions to detect the age association of the visibility and size of the duct measurements. We used non-parametric tests to detect gender and imaging plane differences. Our study included 204 children, 106 (52%) boys and 98 (48%) girls, with a median age of 33 months (range 0-119 months). The children were distributed into five age groups. The common bile duct was visible in all children in all age groups. The pancreatic duct was significantly less visible in the youngest children, group 1 (54/67, 80.5%; P = 0.003) than in the oldest children, group 5 (22/22, 100%). In group 2 the pancreatic duct was seen in 19/21 (90.4%), in group 3 52/55 (94.5%), and in group 4 39/39 (100%). All duct measurements increased with age (P < 0.001; r-value > 0.423), and the incremental differences between ages were significant. The measurement variations between the axial and coronal planes were statistically significant (P < 0.001); however these differences were fractions of millimeters. For example, in group 1 the mean coronal measurement of the CBD was 2.1 mm and the axial

  15. Reference values of MRI measurements of the common bile duct and pancreatic duct in children

    International Nuclear Information System (INIS)

    Gwal, Kriti; Bedoya, Maria A.; Patel, Neal; Darge, Kassa; Anupindi, Sudha A.; Rambhatla, Siri J.; Sreedharan, Ram R.

    2015-01-01

    Magnetic resonance imaging/cholangiopancreatography (MRI/MRCP) is now an essential imaging modality for the evaluation of biliary and pancreatic pathology in children, but there are no data depicting the normal diameters of the common bile duct (CBD) and pancreatic duct. Recognition of abnormal duct size is important and the increasing use of MRCP necessitates normal MRI measurements. To present normal MRI measurements for the common bile duct and pancreatic duct in children. In this retrospective study we searched all children ages birth to 10 years in our MR urography (MRU) database from 2006 until 2013. We excluded children with a history of hepatobiliary or pancreatic surgery. We stratified 204 children into five age groups and retrospectively measured the CBD and the pancreatic duct on 2-D axial and 3-D coronal T2-weighted sequences. We performed statistical analysis, using logistic and linear regressions to detect the age association of the visibility and size of the duct measurements. We used non-parametric tests to detect gender and imaging plane differences. Our study included 204 children, 106 (52%) boys and 98 (48%) girls, with a median age of 33 months (range 0-119 months). The children were distributed into five age groups. The common bile duct was visible in all children in all age groups. The pancreatic duct was significantly less visible in the youngest children, group 1 (54/67, 80.5%; P = 0.003) than in the oldest children, group 5 (22/22, 100%). In group 2 the pancreatic duct was seen in 19/21 (90.4%), in group 3 52/55 (94.5%), and in group 4 39/39 (100%). All duct measurements increased with age (P < 0.001; r-value > 0.423), and the incremental differences between ages were significant. The measurement variations between the axial and coronal planes were statistically significant (P < 0.001); however these differences were fractions of millimeters. For example, in group 1 the mean coronal measurement of the CBD was 2.1 mm and the axial

  16. Bile duct stricture

    Science.gov (United States)

    ... duct, the tube that moves bile from the liver to the small intestine. Bile is a substance that helps with digestion. ... causes of this condition include: Cancer of the bile duct, liver or pancreas Damage and scarring due to a ...

  17. Blocked Tear Duct

    Science.gov (United States)

    ... of the nose (lacrimal sac). From there tears travel down a duct (the nasolacrimal duct) draining into your nose. Once in the nose, tears are reabsorbed. A blockage can occur at any point in the tear drainage system, from the puncta ...

  18. Effects of chronic furosemide on central neural hyperactivity and cochlear thresholds after cochlear trauma in guinea pig

    Directory of Open Access Journals (Sweden)

    Wilhelmina eMulders

    2014-08-01

    Full Text Available Increased neuronal spontaneous firing rates have been observed throughout the central auditory system after trauma to the cochlea and this hyperactivity is believed to be associated with the phantom perception of tinnitus. Previously we have shown in an animal model of hearing loss, that an acute injection with furosemide can significantly decrease hyperactivity after cochlear trauma and eliminate behavioural evidence of tinnitus of early onset. However, furosemide also has the potential to affect cochlear thresholds. In this paper we measured the effects of a chronic (daily injections for 7 days furosemide treatment on the spontaneous firing rate of inferior colliculus neurons and on cochlear thresholds in order to establish whether a beneficial effect on hyperactivity can be obtained without causing additional hearing loss. Guinea pigs were exposed to a 10 kHz, 124dB, 2 hour acoustic trauma, and after 5 days of recovery, were given daily i.p. injections of 80mg/kg furosemide or an equivalent amount of saline. The activity of single IC neurons was recorded 24 hours following the last injection. The furosemide treatment had no effect on cochlear thresholds compared to saline injections but did result in significant reductions in spontaneous firing rates recorded in inferior colliculus. These results that suggest a long term beneficial effect of furosemide on hyperactivity after cochlear trauma may be achievable without detrimental effects on hearing, which is important when considering therapeutic potential.

  19. The cochlear implant as a tinnitus treatment.

    Science.gov (United States)

    Vallés-Varela, Héctor; Royo-López, Juan; Carmen-Sampériz, Luis; Sebastián-Cortés, José M; Alfonso-Collado, Ignacio

    2013-01-01

    Tinnitus is a symptom of high prevalence in patients with cochlear pathology. We studied the evolution of tinnitus in patients undergoing unilateral cochlear implantation for treatment of profound hearing loss. This was a longitudinal, retrospective study of patients that underwent unilateral cochlear implantation and who had bilateral tinnitus. Tinnitus was assessed quantitatively and qualitatively before surgery and at 6 and 12 months after surgery. We evaluated 20 patients that underwent unilateral cochlear implantation with a Nucleus(®) CI24RE Contour Advance™ electrode device. During the periods in which the device was in operation, improvement or disappearance of tinnitus was evidenced in the ipsilateral ear in 65% of patients, and in the contralateral ear, in 50%. In periods in which the device was disconnected, improvement or disappearance of tinnitus was found in the ipsilateral ear in 50% of patients, and in the ear contralateral to the implant in 45% of the patients. In 10% of the patients, a new tinnitus appeared in the ipsilateral ear. The patients with profound hearing loss and bilateral tinnitus treated with unilateral cochlear implantation improved in a high percentage of cases, in the ipsilateral ear and in the contralateral ear. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  20. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  1. Comparison of outcomes in a case of bilateral cochlear implantation using devices manufactured by two different implant companies (Cochlear Corporation and Med-El).

    Science.gov (United States)

    Withers, S J; Gibson, W P; Greenberg, S L; Bray, M

    2011-05-01

    This paper reports a case of a patient who has had bilateral cochlear implants that have been manufactured by different cochlear implant companies (Cochlear Corporation and Med-El). Comparison of speech perception tests following single implant insertion and bilateral insertion (3 and 12 months). The patient was also interviewed to obtain a subjective opinion on their quality of hearing. The patient reported that their Med-El implant had better sound quality than their Cochlear Corporation implant. The speech perception tests however failed to show any difference. Despite no difference found with the objective tests hearing is very subjective and therefore the patient's opinion on the quality of sound is important. It is only a matter of time before other patients are fitted with bilateral cochlear implants from different companies and this information should be collated to allow comparison between manufacturers.

  2. [Inspecting the cochlear scala tympanic with flexible and semi-flexible micro-endoscope].

    Science.gov (United States)

    Zhang, Daoxcing; Zhang, Yankun

    2006-02-01

    Flexible and semi-flexible micro-endoscopes were used in cochlear scala tympani inspection , to explore their application in inner ear examination. Fifteen profound hearing loss patients preparing for cochlear implant were included in this study. During the operation, micro-endoscopy was performed after opening the cochlear scala tympani. And 1 mm diameter semi-flexible micro-endoscope could go as deep as 9 mm into the cochlear scala tympani, while 0. 5 mm diameter flexible micro-endoscope could go as deep as 25 mm. The inspecting results were compared with video recording. Using 0.5 mm flexible micro-endoscope, we canould check cochlear scala tympani with depth range of 15-25 mm, but the video imaging was not clear enough to examine the microstructure in the cochlear. With 1 mm diameter semi-flexible micro-endoscope, we could reach 9 mm deep into the cochlear. During the examination, we found 3 cases with calcification deposit in osseous spiral lamina, l case with granulation tissue in the lateral wall of scala tympani, no abnormal findings in the other 11 cases. Inspecting the cochlear scala tympani with 0.5 mm flexible micro-endoscope, even though we can reach the second circuit of the cochlear, it is difficult to find the pathology in the cochlear because of the poor video imaging. With 1 mm semi-flexible micro-endoscope, we can identify the microstructure of the cochlear clearly and find the pathologic changes, but the inserting depth was limited to 9 mm with limitation to examine the whole cochlear.

  3. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation.

    Science.gov (United States)

    Ramakers, Geerte G J; Kraaijenga, Véronique J C; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Stokroos, Robert J; Free, Rolien H; Frijns, Johan H M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    2017-01-01

    There is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus. To investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years). This study is a secondary analysis as part of a multicenter randomized controlled trial. Thirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs) because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI) and Tinnitus Questionnaire (TQ). The prevalence of preoperative tinnitus was 42% (16/38). One year after bilateral implantation, there was a median difference of -8 (inter-quartile range (IQR): -28 to 4) in THI score and -9 (IQR: -17 to -9) in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group, four patients had an additional benefit of the second CI: a total

  4. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome.

    Science.gov (United States)

    Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya

    2016-01-01

    Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months). Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.

  5. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome

    Directory of Open Access Journals (Sweden)

    Hajime Koyama

    2016-01-01

    Full Text Available Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months. Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.

  6. Ducted fuel injection

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Charles J.

    2018-03-06

    Various technologies presented herein relate to enhancing mixing inside a combustion chamber to form one or more locally premixed mixtures comprising fuel and charge-gas with low peak fuel to charge-gas ratios to enable minimal, or no, generation of soot and other undesired emissions during ignition and subsequent combustion of the locally premixed mixtures. To enable sufficient mixing of the fuel and charge-gas, a jet of fuel can be directed to pass through a bore of a duct causing charge-gas to be drawn into the bore creating turbulence to mix the fuel and the drawn charge-gas. The duct can be located proximate to an opening in a tip of a fuel injector. The duct can comprise of one or more holes along its length to enable charge-gas to be drawn into the bore, and further, the duct can cool the fuel and/or charge-gas prior to combustion.

  7. Outcomes of cochlear implantation in deaf children of deaf parents: comparative study.

    Science.gov (United States)

    Hassanzadeh, S

    2012-10-01

    This retrospective study compared the cochlear implantation outcomes of first- and second-generation deaf children. The study group consisted of seven deaf, cochlear-implanted children with deaf parents. An equal number of deaf children with normal-hearing parents were selected by matched sampling as a reference group. Participants were matched based on onset and severity of deafness, duration of deafness, age at cochlear implantation, duration of cochlear implantation, gender, and cochlear implant model. We used the Persian Auditory Perception Test for the Hearing Impaired, the Speech Intelligibility Rating scale, and the Sentence Imitation Test, in order to measure participants' speech perception, speech production and language development, respectively. Both groups of children showed auditory and speech development. However, the second-generation deaf children (i.e. deaf children of deaf parents) exceeded the cochlear implantation performance of the deaf children with hearing parents. This study confirms that second-generation deaf children exceed deaf children of hearing parents in terms of cochlear implantation performance. Encouraging deaf children to communicate in sign language from a very early age, before cochlear implantation, appears to improve their ability to learn spoken language after cochlear implantation.

  8. Prevention and management of cochlear implant infections.

    Science.gov (United States)

    Gluth, Michael B; Singh, Rajesh; Atlas, Marcus D

    2011-11-01

    Understanding the issues of infection related to an implantable medical device is crucial to all cochlear implant teams. Furthermore, given the risk of central nervous system complications and the relatively high quantity of underlying resource investment associated with cochlear implantation, the stakes of infection are high. The optimal strategies to prevent and manage such infections are still evolving as good-quality prospective data to guide such management decisions are not yet abundant within the medical literature and many recommendations are based on retrospective reviews or anecdotal evidence. We will outline a general strategy to deal with cochlear implant-related infection based on both the authors' experience and the published literature.

  9. Thermal neutrons streaming in straight duct

    International Nuclear Information System (INIS)

    Jehouani, A.; Boulkheir, M.; Ichaoui, R.

    2000-01-01

    The neutron streaming in duct is due to two phenomena: a) direct propagation and b) reflection on duct wall. We have used the Monte Carlo method to evaluate the ratio of the reflected neutrons flux by the duct wall to the total flux at the exit of the duct for iron and aluminium. Ten neutrons energy groups are considered between 10 -5 eV and 10 eV. A Fortran program is developed to evaluate the neutron double differential albedo. It is shown that the two following approximations are largely justified: i) Three collisions in the duct wall are sufficient to attain the asymptotic limit of the multiscattered neutron double differential albedo ii) The points of entry and exit of the neutron in the duct wall may be considered the same for the multiscattered neutrons. For a punctual source at the mouth of the duct, we have determined the direct and the reflected part of the total thermal neutron flux at the exit of the duct for different lengths and different radius of the duct. For a punctual source, we have found that the major contribution to the total flux of neutrons at the exit is due to the neutron reflection by walls and the reflection contribution decreases when the neutron energy decreases. For a constant length of the duct, the reflected part decreases when the duct radius increases while for the disk shaped source we have found the opposite phenomena. The transmitted neutron flux distribution at the exit of the duct are determined for disk shaped source for different neutron energy and for different distance from the exit center. (author)

  10. Vitellointestinal Duct Anomalies in Infancy

    OpenAIRE

    Kadian, Yogender Singh; Verma, Anjali; Rattan, Kamal Nain; Kajal, Pardeep

    2016-01-01

    Background: Vitellointestinal duct (VID) or omphalomesenteric duct anomalies are secondary to the persistence of the embryonic vitelline duct, which normally obliterates by weeks 5–9 of intrauterine life. Methods: This is a retrospective analysis of a total of 16 patients of symptomatic remnants of vitellointestinal duct from period of Jan 2009 to May 2013. Results: Male to female ratio (M:F) was 4.3:1 and mean age of presentation was 2 months and their mode of presentation was: paten...

  11. Gain and frequency tuning within the mouse cochlear apex

    Energy Technology Data Exchange (ETDEWEB)

    Oghalai, John S.; Raphael, Patrick D. [Department of Otolaryngology, Stanford University School of Medicine, Stanford, California (United States); Gao, Simon [Department of Otolaryngology, Stanford University School of Medicine, Stanford, California (United States); Department of Bioengineering, Rice University, Houston, Texas (United States); Lee, Hee Yoon [Department of Otolaryngology, Stanford University School of Medicine, Stanford, California (United States); Department of Electrical Engineering, Stanford University, Stanford, California (United States); Groves, Andrew K. [Department of Neuroscience, Department of Molecular and Human Genetics, and Program in Developmental Biology, Baylor College of Medicine, Houston, Texas (United States); Zuo, Jian [Department of Developmental Neurobiology, St. Jude Children’s Research Hospital, Memphis, Tennessee (United States); Applegate, Brian E. [Department of Biomedical Engineering, Texas A& M University, College Station, Texas (United States)

    2015-12-31

    Normal mammalian hearing requires cochlear outer hair cell active processes that amplify the traveling wave with high gain and sharp tuning, termed cochlear amplification. We have used optical coherence tomography to study cochlear amplification within the apical turn of the mouse cochlea. We measured not only classical basilar membrane vibratory tuning curves but also vibratory responses from the rest of the tissues that compose the organ of Corti. Basilar membrane tuning was sharp in live mice and broad in dead mice, whereas other regions of the organ of Corti demonstrated phase shifts consistent with additional filtering beyond that provided by basilar membrane mechanics. We use these experimental data to support a conceptual framework of how cochlear amplification is tuned within the mouse cochlear apex. We will also study transgenic mice with targeted mutations that affect different biomechanical aspects of the organ of Corti in an effort to localize the underlying processes that produce this additional filtering.

  12. Gain and frequency tuning within the mouse cochlear apex

    International Nuclear Information System (INIS)

    Oghalai, John S.; Raphael, Patrick D.; Gao, Simon; Lee, Hee Yoon; Groves, Andrew K.; Zuo, Jian; Applegate, Brian E.

    2015-01-01

    Normal mammalian hearing requires cochlear outer hair cell active processes that amplify the traveling wave with high gain and sharp tuning, termed cochlear amplification. We have used optical coherence tomography to study cochlear amplification within the apical turn of the mouse cochlea. We measured not only classical basilar membrane vibratory tuning curves but also vibratory responses from the rest of the tissues that compose the organ of Corti. Basilar membrane tuning was sharp in live mice and broad in dead mice, whereas other regions of the organ of Corti demonstrated phase shifts consistent with additional filtering beyond that provided by basilar membrane mechanics. We use these experimental data to support a conceptual framework of how cochlear amplification is tuned within the mouse cochlear apex. We will also study transgenic mice with targeted mutations that affect different biomechanical aspects of the organ of Corti in an effort to localize the underlying processes that produce this additional filtering

  13. [Emotional response to music by postlingually-deafened adult cochlear implant users].

    Science.gov (United States)

    Wang, Shuo; Dong, Ruijuan; Zhou, Yun; Li, Jing; Qi, Beier; Liu, Bo

    2012-10-01

    To assess the emotional response to music by postlingually-deafened adult cochlear implant users. Munich music questionnaire (MUMU) was used to match the music experience and the motivation of use of music between 12 normal-hearing and 12 cochlear implant subjects. Emotion rating test in Musical Sounds in Cochlear Implants (MuSIC) test battery was used to assess the emotion perception ability for both normal-hearing and cochlear implant subjects. A total of 15 pieces of music phases were used. Responses were given by selecting the rating scales from 1 to 10. "1" represents "very sad" feeling, and "10" represents "very happy feeling. In comparison with normal-hearing subjects, 12 cochlear implant subjects made less active use of music for emotional purpose. The emotion ratings for cochlear implant subjects were similar to normal-hearing subjects, but with large variability. Post-lingually deafened cochlear implant subjects on average performed similarly in emotion rating tasks relative to normal-hearing subjects, but their active use of music for emotional purpose was obviously less than normal-hearing subjects.

  14. Patent arterial duct

    Directory of Open Access Journals (Sweden)

    Martin Robin P

    2009-07-01

    Full Text Available Abstract Patent arterial duct (PAD is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher prevalence is found in preterm infants, especially those with low birth weight. The female to male ratio is 2:1. Most patients are asymptomatic when the duct is small. With a moderate-to-large duct, a characteristic continuous heart murmur (loudest in the left upper chest or infraclavicular area is typical. The precordium may be hyperactive and peripheral pulses are bounding with a wide pulse pressure. Tachycardia, exertional dyspnoea, laboured breathing, fatigue or poor growth are common. Large shunts may lead to failure to thrive, recurrent infection of the upper respiratory tract and congestive heart failure. In the majority of cases of PAD there is no identifiable cause. Persistence of the duct is associated with chromosomal aberrations, asphyxia at birth, birth at high altitude and congenital rubella. Occasional cases are associated with specific genetic defects (trisomy 21 and 18, and the Rubinstein-Taybi and CHARGE syndromes. Familial occurrence of PAD is uncommon and the usual mechanism of inheritance is considered to be polygenic with a recurrence risk of 3%. Rare families with isolated PAD have been described in which the mode of inheritance appears to be dominant or recessive. Familial incidence of PAD has also been linked to Char syndrome, familial thoracic aortic aneurysm/dissection associated with patent arterial duct, and familial patent arterial duct and bicuspid aortic valve associated with hand abnormalities. Diagnosis is based on clinical examination and confirmed with transthoracic echocardiography. Assessment of ductal blood flow can be made using colour flow mapping and pulsed wave Doppler. Antenatal diagnosis is not possible, as PAD is a normal structure during antenatal life. Conditions with signs and symptoms of

  15. United Kingdom national paediatric bilateral cochlear implant audit: preliminary results.

    Science.gov (United States)

    Cullington, Helen; Bele, Devyanee; Brinton, Julie; Lutman, Mark

    2013-11-01

    Prior to 2009, United Kingdom (UK) public funding was mainly only available for children to receive unilateral cochlear implants. In 2009, the National Institute for Health and Care Excellence published guidance for cochlear implantation following their review. According to these guidelines, all suitable children are eligible to have simultaneous bilateral cochlear implants or a sequential bilateral cochlear implant if they had received the first before the guidelines were published. Fifteen UK cochlear implant centres formed a consortium to carry out a multi-centre audit. The audit involves collecting data from simultaneously and sequentially implanted children at four intervals: before bilateral cochlear implants or before the sequential implant, 1, 2, and 3 years after bilateral implants. The measures include localization, speech recognition in quiet and background noise, speech production, listening, vocabulary, parental perception, quality of life, and surgical data including complications. The audit has now passed the 2-year point, and data have been received on 850 children. This article provides a first view of some data received up until March 2012.

  16. Tinnitus and Sleep Difficulties After Cochlear Implantation.

    Science.gov (United States)

    Pierzycki, Robert H; Edmondson-Jones, Mark; Dawes, Piers; Munro, Kevin J; Moore, David R; Kitterick, Pádraig T

    To estimate and compare the prevalence of and associations between tinnitus and sleep difficulties in a sample of UK adult cochlear implant users and those identified as potential candidates for cochlear implantation. The study was conducted using the UK Biobank resource, a population-based cohort of 40- to 69-year olds. Self-report data on hearing, tinnitus, sleep difficulties, and demographic variables were collected from cochlear implant users (n = 194) and individuals identified as potential candidates for cochlear implantation (n = 211). These "candidates" were selected based on (i) impaired hearing sensitivity, inferred from self-reported hearing aid use and (ii) impaired hearing function, inferred from an inability to report words accurately at negative signal to noise ratios on an unaided closed-set test of speech perception. Data on tinnitus (presence, persistence, and related distress) and on sleep difficulties were analyzed using logistic regression models controlling for gender, age, deprivation, and neuroticism. The prevalence of tinnitus was similar among implant users (50%) and candidates (52%; p = 0.39). However, implant users were less likely to report that their tinnitus was distressing at its worst (41%) compared with candidates (63%; p = 0.02). The logistic regression model suggested that this difference between the two groups could be explained by the fact that tinnitus was less persistent in implant users (46%) compared with candidates (72%; p reported difficulties with sleep were similar among implant users (75%) and candidates (82%; p = 0.28), but participants with tinnitus were more likely to report sleep difficulties than those without (p explanation is supported by the similar prevalence of sleep problems among implant users and potential candidates for cochlear implantation, despite differences between the groups in tinnitus persistence and related emotional distress. Cochlear implantation may therefore not be an appropriate intervention

  17. The preoperative imaging evaluation for cochlear implantation

    International Nuclear Information System (INIS)

    Liu Zhonglin; Wang Zhenchang; Fu Lin; Li Yong; Xian Junfang; Yang Bentao; Lan Baosen; Li Yongxin; Zheng Jun; Song Yan; Liu Bo; Chen Xueqing; He Haili

    2006-01-01

    Objective: To analyze CT and MRI findings of temporal bone and to evaluate preoperative diagnostic value for cochlear implantation. Methods: One hundred and sixty candidates for cochlear implantation were examined with axial CT scan, 64 of them also with coronal CT scan, and 119 patients with MRI. Results: All of 320 ears were well-aerated, and 206 ears had mastoid cavities extended posteriorly to the sigmoid sinus. The length from posterior-lateral tympanic wall to the outer cortex was (2.34±0.42) mm (left side) and (2.25±0.40) mm (right side) (U=1.887, P 1 and T 2 signal on MRI. The congenital malformations of inner ear occurred in 67 ears, including complete dysplasia in 1 ear, cochlear hypodysplasia in 6 ears, Mondini deformation in 5 ears, enlarged vestibular aqueduct in 40 ears, dysplastic semicircular canal and the vestibulae in 10 ears, and narrowing of internal auditory canal in 5 ears. Conclusion: Preoperative imaging examinations can provide critical information to ensure successful cochlear' implantation. (authors)

  18. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation

    Directory of Open Access Journals (Sweden)

    Geerte G. J. Ramakers

    2017-11-01

    Full Text Available ImportanceThere is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus.ObjectiveTo investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years.Study designThis study is a secondary analysis as part of a multicenter randomized controlled trial.MethodsThirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI and Tinnitus Questionnaire (TQ.ResultsThe prevalence of preoperative tinnitus was 42% (16/38. One year after bilateral implantation, there was a median difference of −8 (inter-quartile range (IQR: −28 to 4 in THI score and −9 (IQR: −17 to −9 in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group

  19. Eversion Bile Duct Anastomosis: A Safe Alternative for Bile Duct Size Discrepancy in Deceased Donor Liver Transplantation.

    Science.gov (United States)

    Leal-Leyte, Pilar; McKenna, Greg J; Ruiz, Richard M; Anthony, Tiffany L; Saracino, Giovanna; Giuliano, Testa; Klintmalm, Goran B; Kim, Peter Tw

    2018-04-10

    Introduction Bile duct size discrepancy in liver transplantation may increase the risk of biliary complications. The aim of this study was to evaluate the safety and outcomes of the eversion bile duct anastomosis technique in deceased donor liver transplantation (DDLT) with duct to duct anastomosis. Methods A total of 210 patients who received a DDLT with duct to duct anastomosis from 2012 to 2017 were divided into two groups: those who had eversion bile duct anastomosis (N=70) and standard bile duct anastomosis (N=140). Biliary complications rates were compared between the two groups. Results There was no difference in the cumulative incidence of biliary strictures (P=0.20) and leaks (P=0.17) between the two groups. The biliary complication rate in the eversion group was 14.3% and 11.4% in the standard anastomosis group. All the biliary complications in the eversion group were managed with endoscopic stenting. A severe size mismatch (≥3:1 ratio) was associated with a significantly higher incidence of biliary strictures (44.4%) compared to 2:1 ratio (8.2%), (P=0.002). Conclusion The use of the eversion technique is a safe alternative for bile duct discrepancy in deceased donor liver transplantation; however, severe bile duct size mismatch may be a risk factor for biliary strictures with such technique. This article is protected by copyright. All rights reserved. © 2018 by the American Association for the Study of Liver Diseases.

  20. A prospective study evaluating cochlear implant management skills: development and validation of the Cochlear Implant Management Skills survey.

    Science.gov (United States)

    Bennett, R J; Jayakody, D M P; Eikelboom, R H; Taljaard, D S; Atlas, M D

    2016-02-01

    To investigate the ability of cochlear implant (CI) recipients to physically handle and care for their hearing implant device(s) and to identify factors that may influence skills. To assess device management skills, a clinical survey was developed and validated on a clinical cohort of CI recipients. Survey development and validation. A prospective convenience cohort design study. Specialist hearing implant clinic. Forty-nine post-lingually deafened, adult CI recipients, at least 12 months postoperative. Survey test-retest reliability, interobserver reliability and responsiveness. Correlations between management skills and participant demographic, audiometric, clinical outcomes and device factors. The Cochlear Implant Management Skills survey was developed, demonstrating high test-retest reliability (0.878), interobserver reliability (0.972) and responsiveness to intervention (skills training) [t(20) = -3.913, P = 0.001]. Cochlear Implant Management Skills survey scores range from 54.69% to 100% (mean: 83.45%, sd: 12.47). No associations were found between handling skills and participant factors. This is the first study to demonstrate a range in cochlear implant device handling skills in CI recipients and offers clinicians and researchers a tool to systematically and objectively identify shortcomings in CI recipients' device handling skills. © 2015 John Wiley & Sons Ltd.

  1. Should you get your heating ducts cleaned?

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Canada Mortgage and Housing Corporation conducted research into duct cleaning during which time several houses were tested for hot air furnace duct performance before and after cleaning. Duct cleaning is a major industry which claims that cleaning of ducts will provide you with better indoor air quality, reduce household molds and allergens, get rid of house dust, result in more airflow and better delivery of warm air and reduce energy costs. This report does not substantiate those claims. Researchers found little or no discernible differences in the concentrations of house airborne particles or in duct airflows due to duct cleaning. This is because ducts are metal passages that cannot create dust. Most household dusts come from outdoors that has been tracked in or blows through windows and other openings. While duct cleaning may be justifiable personally, it does not change the quality of the air you breathe, nor will it significantly affect airflow or heating costs. Some filters effectively clean the air in the ducts but they do not create a dust-free environment because of the above-mentioned dust sources. The only time that duct cleaning may make sense is if you have water in your ducts that can result in mold growth, if you are moving into a newly constructed house to remove drywall dust, if your are having trouble with furnace airflow, or if you see an accumulation of debris in the return air ducts. It was emphasized that broadcast spraying of biocides within the duct system should not be performed.

  2. The Human Cochlear Mechanical Nonlinearity Inferred via Psychometric Functions

    Directory of Open Access Journals (Sweden)

    Nizami Lance

    2013-12-01

    Extension of the model of Schairer and colleagues results in credible cochlear nonlinearities in man, suggesting that forward-masking provides a non-invasive way to infer the human mechanical cochlear nonlinearity.

  3. Transcanal labyrinthectomy for intractable vertigo after unilateral cochlear implantation.

    Science.gov (United States)

    Heidenreich, Katherine D; Basura, Gregory J; Zwolan, Teresa A; El-Kashlan, Hussam K; Telian, Steven A

    2011-10-01

    Document the use of transcanal labyrinthectomy to treat disabling attacks of vertigo after unilateral cochlear implantation. A 46-year-old woman with severe-profound bilateral sensorineural hearing loss secondary to enlarged vestibular aqueducts underwent cochlear implantation for her right ear with a Nucleus Freedom device. The surgery was uneventful, and postoperative imaging confirmed that the electrode was positioned properly. She developed episodic vertigo 10 to 14 days after the implant surgery, which failed to improve with aggressive vestibular rehabilitation therapy. Plugging of the round window for possible perilymphatic fistula did not relieve her symptoms. Right transcanal labyrinthectomy supplemented by filling the vestibule with gentamicin-soaked Gelfoam and then a customized vestibular rehabilitation program. Comparison of vestibular symptoms and cochlear implant performance before and after transcanal labyrinthectomy. The patient had immediate relief of symptoms, and the function of the cochlear implant was not adversely affected. Transcanal labyrinthectomy may be an effective method to ablate the vestibular end organ after unilateral cochlear implantation. It can offer relief of disabling vertigo without adversely affecting the performance of the implant.

  4. Fourteen-years experience with cochlear implantation in Ramathibodi Hospital.

    Science.gov (United States)

    Kasemsuwan, Lalida; Cheewaruangroj, Wichit; Tungkeeratichai, Jumroon; Bhongmakapat, Thongchai; Thawin, Cheamchit; Lertsukprasert, Krisna; Tiravanitchakul, Rattinan; Dara, Rada; Laothamatas, Jiraporn

    2010-12-01

    To review the cochlear implant program in Ramathibodi Hospital and share experience of cochlear implantation emphasized on clinical and surgical outcomes. Retrospective review of 143 ears (140 patients) operated with cochlear implant between 1995 and 2009. The demographic data including etiology of deafness and findings from temporal bone CTscans were reviewed. The authors' experience with cochlear implant surgery in terms of patient selection, patient advisory clinic, necessary equipment, pre- and postoperative evaluations, surgical techniques and complications were discussed. Most congenital origin was unknown etiology and congenital rubella was the most common known cause. From the CT scans of congenital deafness, vestibular aqueduct dilatation was the most common and found in 29.31% while Mondini malformation was shown to be 16.37%. The authors' surgical technique of using the pocket method and designed bony ridge at cortical mastoid rim had helped stabilizing the implant and electrode fancoil. During the last two years, no complication or revision surgery was detected. Cochlear implant surgery in both children and adults can result in good surgical outcome and fewer complications under experienced surgeons and a good team.

  5. Cochlear injury and adaptive plasticity of the auditory cortex

    Directory of Open Access Journals (Sweden)

    ANNA R. eFETONI

    2015-02-01

    Full Text Available Growing evidence suggests that cochlear stressors as noise exposure and aging can induce homeostatic/maladaptive changes in the central auditory system from the brainstem to the cortex. Studies centered on such changes have revealed several mechanisms that operate in the context of sensory disruption after insult (noise trauma, drug- or age-related injury. The oxidative stress is central to current theories of induced sensory neural hearing loss and aging, and interventions to attenuate the hearing loss are based on antioxidant agent. The present review addresses the recent literature on the alterations in hair cells and spiral ganglion neurons due to noise-induced oxidative stress in the cochlea, as well on the impact of cochlear damage on the auditory cortex neurons. The emerging image emphasizes that noise-induced deafferentation and upward spread of cochlear damage is associated with the altered dendritic architecture of auditory pyramidal neurons. The cortical modifications may be reversed by treatment with antioxidants counteracting the cochlear redox imbalance. These findings open new therapeutic approaches to treat the functional consequences of the cortical reorganization following cochlear damage.

  6. Influence of cochlear implantation on peripheral vestibular receptor function.

    Science.gov (United States)

    Krause, Eike; Louza, Julia P R; Wechtenbruch, Juliane; Gürkov, Robert

    2010-06-01

    The objectives of this study were 1) to assess the influence of a cochlear implantation on peripheral vestibular receptor function in the inner ear in the implant and in the nonimplant side, and 2) to analyze a possible correlation with resulting vertigo symptoms. Prospective clinical study. Cochlear implant center at tertiary referral hospital. A total of 32 patients, aged 15 to 83 years, undergoing cochlear implantation were assessed pre- and postoperatively for caloric horizontal semicircular canal response and vestibular-evoked myogenic potentials of the sacculus, and postoperatively for subjective vertigo symptoms. Patients with vertigo were compared with patients without symptoms with regard to the findings of the vestibular function tests. Cochlear implantation represents a significant risk factor for horizontal semicircular canal impairment (P 0.05). Cochlear implantation is a relevant risk factor for damage of peripheral vestibular receptor function. Therefore, preservation not only of residual hearing function but also of vestibular function should be aimed for, by using minimally invasive surgical techniques. Copyright 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  7. Verbal Working Memory in Children With Cochlear Implants

    Science.gov (United States)

    Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.

    2017-01-01

    Purpose Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method A dual-component model of working memory was adopted, and a serial recall task measured storage and processing. Potential predictor variables were phonological awareness, vocabulary knowledge, nonverbal IQ, and several treatment variables. Potential dependent functions were literacy, expressive language, and speech-in-noise recognition. Results Children with cochlear implants showed deficits in storage and processing, similar in size to those at second grade. Predictors of verbal working memory differed across groups: Phonological awareness explained the most variance in children with normal hearing; vocabulary explained the most variance in children with cochlear implants. Treatment variables explained little of the variance. Where potentially dependent functions were concerned, verbal working memory accounted for little variance once the variance explained by other predictors was removed. Conclusions The verbal working memory deficits of children with cochlear implants arise due to signal degradation, which limits their abilities to acquire phonological awareness. That hinders their abilities to store items using a phonological code. PMID:29075747

  8. Cochlear implantation for single-sided deafness and tinnitus suppression.

    Science.gov (United States)

    Holder, Jourdan T; O'Connell, Brendan; Hedley-Williams, Andrea; Wanna, George

    To quantify the potential effectiveness of cochlear implantation for tinnitus suppression in patients with single-sided deafness using the Tinnitus Handicap Inventory. The study included 12 patients with unilateral tinnitus who were undergoing cochlear implantation for single-sided deafness. The Tinnitus Handicap Inventory was administered at the patient's cochlear implant candidacy evaluation appointment prior to implantation and every cochlear implant follow-up appointment, except activation, following implantation. Patient demographics and speech recognition scores were also retrospectively recorded using the electronic medical record. A significant reduction was found when comparing Tinnitus Handicap Inventory score preoperatively (61.2±27.5) to the Tinnitus Handicap Inventory score after three months of cochlear implant use (24.6±28.2, p=0.004) and the Tinnitus Handicap Inventory score beyond 6months of CI use (13.3±18.9, p=0.008). Further, 45% of patients reported total tinnitus suppression. Mean CNC word recognition score improved from 2.9% (SD 9.4) pre-operatively to 40.8% (SD 31.7) by 6months post-activation, which was significantly improved from pre-operative scores (p=0.008). The present data is in agreement with previously published studies that have shown an improvement in tinnitus following cochlear implantation for the large majority of patients with single-sided deafness. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Image Registration of Cochlear µCT Data Using Heat Distribution Similarity

    DEFF Research Database (Denmark)

    Kjer, Hans Martin; Vera, Sergio; Fagertun, Jens

    2015-01-01

    Better understanding of the anatomical variability of the human cochlear is important for the design and function of Cochlear Implants. Good non-rigid alignment of high-resolution cochlear μCT data is a challenging task. In this paper we study the use of heat distribution similarity between sampl...

  10. Modelling Cochlear Mechanics

    Directory of Open Access Journals (Sweden)

    Guangjian Ni

    2014-01-01

    Full Text Available The cochlea plays a crucial role in mammal hearing. The basic function of the cochlea is to map sounds of different frequencies onto corresponding characteristic positions on the basilar membrane (BM. Sounds enter the fluid-filled cochlea and cause deflection of the BM due to pressure differences between the cochlear fluid chambers. These deflections travel along the cochlea, increasing in amplitude, until a frequency-dependent characteristic position and then decay away rapidly. The hair cells can detect these deflections and encode them as neural signals. Modelling the mechanics of the cochlea is of help in interpreting experimental observations and also can provide predictions of the results of experiments that cannot currently be performed due to technical limitations. This paper focuses on reviewing the numerical modelling of the mechanical and electrical processes in the cochlea, which include fluid coupling, micromechanics, the cochlear amplifier, nonlinearity, and electrical coupling.

  11. Bile Duct Adenoma with Oncocytic Features

    Directory of Open Access Journals (Sweden)

    E. J. Johannesen

    2014-01-01

    Full Text Available Bile duct adenomas are benign bile duct proliferations usually encountered as an incidental finding. Oncocytic bile duct neoplasms are rare and the majority are malignant. A 61-year-old male with a diagnosis of colorectal adenocarcinoma was undergoing surgery when a small white nodule was discovered on the surface of the right lobe of his liver. This lesion was composed of cytologically bland cells arranged in tightly packed glands. These cells were immunopositive for cytokeratin 7, negative for Hep Par 1, contained mucin, and had a Ki67 proliferation index of 8%. The morphology, immunophenotype, presence of mucin, and normal appearing bile ducts, as well as the increased Ki67 proliferation rate, were consistent with a bile duct adenoma with oxyphilic (oncocytic change. Oncocytic tumors in the liver are rare; the first described in 1992. Only two bile duct adenomas with oncocytic change have been reported and neither of them had reported mucin production or the presence of normal appearing bile ducts within the lesion.

  12. Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.

    Science.gov (United States)

    Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan

    2011-01-01

    With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. Cochlear nucleus neuron analysis in individuals with presbycusis.

    Science.gov (United States)

    Hinojosa, Raul; Nelson, Erik G

    2011-12-01

    The aim of this study was to analyze the cochlear nucleus neuron population in individuals with normal hearing and presbycusis. Retrospective study of archival human temporal bone and brain stem tissues. Using strict inclusion criteria, the temporal bones and cochlear nuclei from six normal hearing individuals and four individuals with presbycusis were selected for analysis. The spiral ganglion cell population, the cochlear nucleus neuron population, and the cell body size of the neurons were quantified in these cases. A relationship was not observed between age and the spiral ganglion cell population in the normal hearing group. Presbycusis subjects exhibited a reduced spiral ganglion cell population. The mean cochlear nucleus neuron population was observed to be significantly higher in the presbycusis group (mean ± standard deviation: 114,170 ± 10,570) compared to the normal hearing group (91,470 ± 9,510) (P = .019). This difference was predominantly the result of greater multipolar and granule cell neuron populations. Only the fusiform neuron type exhibited a significantly different mean cell body cross-sectional area between the normal hearing group (242 ± 27) and the presbycusis group (300 ± 37) (P = .033). This investigation is the first time, to our knowledge, that the populations of the eight neuron types in the cochlear nucleus have been quantified in both normal hearing individuals and individuals with presbycusis. The data support the concept that presbycusis is not an effect of aging alone but instead may be a condition that predisposes one to hearing loss with advancing age and is characterized by a congenitally elevated cochlear nucleus neuron population. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  14. Threshold shift: effects of cochlear implantation on the risk of pneumococcal meningitis.

    Science.gov (United States)

    Wei, Benjamin P C; Shepherd, Robert K; Robins-Browne, Roy M; Clark, Graeme M; O'Leary, Stephen J

    2007-04-01

    The study goals were to examine whether cochlear implantation increases the risk of meningitis in the absence of other risk factors and to understand the pathogenesis of pneumococcal meningitis post cochlear implantation. Four weeks following surgery, 54 rats (18 of which received a cochleostomy alone, 18 of which received a cochleostomy and acute cochlear implantation using standard surgical techniques, and 18 of which received a cochlear implant) were infected with Streptococcus pneumoniae via three different routes of bacterial inoculation (middle ear, inner ear, and intraperitoneal) to represent all potential routes of bacterial infection from the upper respiratory tract to the meninges. The presence of a cochlear implant reduced the threshold of bacteria required to cause pneumococcal meningitis from all routes of infection in healthy animals. The presence of a cochlear implant increases the risk of pneumococcal meningitis regardless of the route of bacterial infection. Early detection and treatment of pneumococcal infection such as otitis media may be required, as cochlear implantation may lead to a reduction of infectious threshold for meningitis.

  15. Scala vestibuli cochlear implantation in patients with partially ossified cochleas.

    Science.gov (United States)

    Berrettini, Stefano; Forli, Francesca; Neri, Emanuele; Segnini, Giovanni; Franceschini, Stefano Sellari

    2002-11-01

    Partial cochlear obstruction is a relatively common finding in candidates for cochlear implants and frequently involves the inferior segment of the scala tympani in the basal turn of the cochlea. In such patients, the scala vestibuli is often patent and offers an alternative site for implantation. The current report describes two patients with such partial obstruction of the inferior segment of the basal cochlear turn, caused in one case by systemic vasculitis (Takayasu's disease) and in the other by obliterative otosclerosis. A scala vestibuli implantation allowed for complete insertion of the electrode array. No problems were encountered during the surgical procedures and the good post-operative hearing and communicative outcomes achieved were similar to those reported in patients without cochlear ossification. The importance of accurate pre-operative radiological study of the inner ear is underscored, to disclose the presence and define the features of the cochlear ossification and ultimately to properly plan the surgical approach.

  16. Vacuum exhaust duct used for thermonuclear device

    International Nuclear Information System (INIS)

    Tachikawa, Nobuo; Kondo, Mitsuaki; Honda, Tsutomu.

    1990-01-01

    The present invention concerns a vacuum exhaust duct used for a thermonuclear device. A cylindrical metal liners is lined with a gap to the inside of a vacuum exhaust duct main body. Bellows are connected to both ends of the metal liners and the end of the bellows is welded to the vacuum exhaust duct main body. Futher, a heater is mounted to the metal liner on the side of the vacuum exhaust duct main body, and the metal liner is heated by the heater to conduct baking for the vacuum exhaust duct main body. Accordingly, since there is no requirement for elevating the temperature of the vacuum exhaust duct upon conducting baking, the vacuum exhaust duct scarcely suffers substantial deformation due to heat expansion. Further, there is also no substantial deformation for the bellows disposed between the outer circumference of the vacuum vessel and a portion of a vacuum exhaust duct, so that the durability of the bellows is greatly improved. (I.S.)

  17. Quadcopter thrust optimization with ducted-propeller

    Directory of Open Access Journals (Sweden)

    Kuantama Endrowednes

    2017-01-01

    Full Text Available In relation to quadcopter body frame model, propeller can be categorized into propeller with ducted and without ducted. This study present differences between those two using CFD (Computational Fluid Dynamics method. Both categories utilize two blade-propeller with diameter of 406 (mm. Propeller rotation generates acceleration per time unit on the volume of air. Based on the behavior of generated air velocity, ducted propeller can be modeled into three versions. The generated thrust and performance on each model were calculated to determine the best model. The use of ducted propeller increases the total weight of quadcopter and also total thrust. The influence of this modeling were analyzed in detail with variation of angular velocity propeller from 1000 (rpm to 9000 (rpm. Besides the distance between propeller tip and ducted barrier, the size of ducted is also an important part in thrust optimization and total weight minimization of quadcopter.

  18. Production of verb tenses in children with cochlear implants

    Directory of Open Access Journals (Sweden)

    Sokolovac Ivana

    2016-01-01

    Full Text Available The production of verb tenses leads to better language development of children with cochlear implants. The aim of this study was to assess the acquisition of verb tenses in children with cochlear implants. The sample included 60 children, aged from 9 to 15, with average intellectual abilities. The study group consisted of 30 patients with cochlear implants, with no additional disabilities. The control group consisted of 30 subjects with typical speech - language development and preserved hearing. The acquisition of basic tenses was assessed by 'Corpus for the Assessment of the Use of Tenses' (Dimić, 2003. Significant statistical differences were found in the use of the present tense in children with cochlear implants and hearing children (t=-4.385; p<0.001 as well as in the use of the past tense (t=-4.650; p<0.001, and the future tense (t=-4.269; p<0.001. There was also a significant difference in the use of irregular verb 'go' (t=-3.958; p<0.001, as well as in the combination of the present and the past tense (t=-5.806; p<0.001. The present tense was used correctly by most children with cochlear implants (70%, followed by the past tense (53%, and finally the future tense (23%. Children with cochlear implants, even after several years of re/habilitation, do not reach the grammatical development of children with normal hearing.

  19. Hair Barrette Induced Cochlear Implant Receiver Stimulator Site Infection with Extrusion

    Directory of Open Access Journals (Sweden)

    Trung N. Le

    2015-01-01

    Full Text Available Background. Cochlear implant infections and extrusion are uncommon but potentially devastating complications. Recent literature suggests conservative management can be employed. Local measures inclusive of aggressive surgical debridement with vascularized flaps and parenteral antibiotics represent a viable option and often permit device salvage. However, explantation should be considered if there is evidence of systemic, intracranial, or intractable infection. Method. A Case report and literature review. Case Report. This case illustrates a complicated local wound infection associated with cochlear implantation due to transcutaneous adherence of a ferrous hair barrette to a cochlear implant magnet. Reconstruction of computed tomography (CT data with 3D volume rendering significantly improved the value of the images and facilitated patient counseling as well as operative planning. Conclusion. Cochlear implant infections can be associated with foreign bodies. CT images are beneficial in the evaluation of cochlear implant complications. 3D CT images provide a comprehensive view of the site of interest, displaying the relationship of the hardware to the skull and soft tissues, while minimizing associated artifacts. Cochlear implant patients should consider use of nonmetallic hair devices.

  20. Prevalence of inner ear anomalies among cochlear implant candidates.

    Science.gov (United States)

    Aldhafeeri, Ahmad M; Alsanosi, Abdulrahman A

    2016-10-01

    To determine the prevalence of inner ear anomalies and the frequency of different anomaly types among cochlear implant recipients. This study included a retrospective chart review of all patients who received cochlear implants between January 2009 and January 2013 in King Abdulaziz University Hospital cochlear implant program in Riyadh, Saudi Arabia. All subjects underwent thin-cut CT of the temporal bone and MRI. The collected data included age, gender, and CT and MRI findings regarding temporal bone anomalies. Patients with any identified congenital inner ear anomalies were included in the study.  In total, 316 patients' cases were reviewed. Inner ear malformations were identified in 24 patients, which represented a prevalence of 7.5%. Among these 24 patients, 8 (33.3%) presented with a large vestibular aqueduct (LVA), 8 (33.3%) semicircular canal (SCC) dysplasia, 7 (29.1%) classical Mondini deformity, and one (4.1%) cochlear hypoplasia. The prevalence of inner ear anomalies among cochlear implant recipients was 7.5%. This result is consistent with findings worldwide. The most common anomalies were LVA and SCC hypoplasia; by contrast, in other regions, the most common anomaly is either the Mondini deformity, or LVA.

  1. Hyperbaric oxygen upregulates cochlear constitutive nitric oxide synthase

    Directory of Open Access Journals (Sweden)

    Kao Ming-Ching

    2011-02-01

    Full Text Available Abstract Background Hyperbaric oxygen therapy (HBOT is a known adjuvant for treating ischemia-related inner ear diseases. Controversies still exist in the role of HBOT in cochlear diseases. Few studies to date have investigated the cellular changes that occur in inner ears after HBOT. Nitric oxide, which is synthesized by nitric oxide synthase (NOS, is an important signaling molecule in cochlear physiology and pathology. Here we investigated the effects of hyperbaric oxygen on eardrum morphology, cochlear function and expression of NOS isoforms in cochlear substructures after repetitive HBOT in guinea pigs. Results Minor changes in the eardrum were observed after repetitive HBOT, which did not result in a significant hearing threshold shift by tone burst auditory brainstem responses. A differential effect of HBOT on the expression of NOS isoforms was identified. Upregulation of constitutive NOS (nNOS and eNOS was found in the substructures of the cochlea after HBOT, but inducible NOS was not found in normal or HBOT animals, as shown by immunohistochemistry. There was no obvious DNA fragmentation present in this HBOT animal model. Conclusions The present evidence indicates that the customary HBOT protocol may increase constitutive NOS expression but such upregulation did not cause cell death in the treated cochlea. The cochlear morphology and auditory function are consequently not changed through the protocol.

  2. Exploring the experiences of teenagers with cochlear implants.

    Science.gov (United States)

    Watson, Victoria; Verschuur, Carl; Lathlean, Judith

    2016-11-01

    Teenage cochlear implant users' perceptions of deafness, surgery, fitting of the device and life as a cochlear implant wearer were explored in order to gain a more comprehensive understanding of teenagers' experiences of living with the device. Semi-structured in-depth interviews were undertaken and analysed using thematic analysis. Ten teenagers aged 14-16 years with at least one cochlear implant were interviewed. Seven teenagers experienced great pre-operative anxiety and two reported significant post-operative pain. Four of the teenagers described a mismatch between their expectations and the disappointing reality of adjusting to the device. However, all the teenagers reported an enhanced sense of well-being as a result of being able to interact more easily with their world around them. The teenagers differed in the extent to which they identified with the hearing and deaf world. Despite the early challenges, over time the teenagers experienced many functional and psychosocial benefits. Most felt their lives were now easier as a result of the cochlear implant(s). They described complex, flexible identities. By giving prominence to the teenagers' voices this study has added new knowledge concerning their experience of surgery. The findings also more fully revealed the challenges of adjusting to the device and the impact of having a cochlear implant on the teenagers' identities. Clinical recommendations are made to address the gaps in service highlighted by these findings.

  3. Radiation resistant ducted superconductive coil

    International Nuclear Information System (INIS)

    Schleich, A.

    1976-01-01

    The radiation-resistant ducted superconductive coil consists of a helically wound electrical conductor constituted by an electrically conductive core of superconductive material provided with a longitudinally extending cooling duct. The core is covered with a layer of inorganic insulating material and the duct is covered by an electrically conductive metallic gas-tight sheath. The metallic sheaths on adjacent turns of the coil are secured together. 2 Claims, 4 Drawing Figures

  4. Verbal Working Memory in Children with Cochlear Implants

    Science.gov (United States)

    Nittrouer, Susan; Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.

    2017-01-01

    Purpose: Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants: Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method: A dual-component model of…

  5. Working memory in Farsi-speaking children with normal development and cochlear implant.

    Science.gov (United States)

    Soleymani, Zahra; Amidfar, Meysam; Dadgar, Hooshang; Jalaie, Shohre

    2014-04-01

    Working memory has an important role in language acquisition and development of cognition skills. The ability of encoding, storage and retrieval of phonological codes, as activities of working memory, acquired by audition sense. Children with cochlear implant experience a period that they are not able to perceive sounds. In order to assess the effect of hearing on working memory, we investigated working memory as a cognition skill in children with normal development and cochlear implant. Fifty students with normal hearing and 50 students with cochlear implant aged 5-7 years participated in this study. Children educated in the preschool, the first and second grades. Children with normal development were matched based on age, gender, and grade of education with cochlear implant. Two components of working memory including phonological loop and central executive were compared between two groups. Phonological loop assessed by nonword repetition task and forward digit span. To assess central executive component backward digit span was used. The developmental trend was studied in children with normal development and cochlear implant as well. The effect of age at implantation in children with cochlear implants on components of working memory was investigated. There are significant differences between children with normal development and cochlear implant in all tasks that assess working memory (p memory between different grades showed significant differences both in children with normal development and in children with cochlear implant (p implied that children with cochlear implant may experience difficulties in working memory. Therefore, these children have problems in encoding, practicing, and repeating phonological units. The results also suggested working memory develops when the child grows up. In cochlear implant children, with decreasing age at implantation and increasing their experience in perceiving sound, working memory skills improved. Copyright © 2014 Elsevier

  6. Modified nasolacrimal duct stenting

    International Nuclear Information System (INIS)

    Tian Min; Jin Mei; Chen Huanjun; Li Yi

    2008-01-01

    Objective: Traditional nasolacrimal duct stenting possesses some shortcoming including difficulty of pulling ball head guide wire from the nasal cavity with turbinate hypertrophy and nasal septal deviation. The new method of nose-oral tube track establishment can overcome the forementioned and increase the successful rate. Methods: 5 F catheter and arterial sheath were modified to be nasolacrimal duct stent delivery device respectively. Antegrade dacryocystography was taken firstly to display the obstructed site and followed by the modified protocol of inserting the guide wire through nasolacrimal duct and nasal cavity, and establishing the stent delivery track for retrograde stent placement. Results: 5 epiphora patients with failure implantation by traditional method were all succeeded through the modified stenting (100%). During 6-mouth follow-up, no serious complications and reocclusion occurred. Conclusion: The establishment of eye-nose-mouth-nose of external nasal guide wire track can improve the successful rate of nasolacrimal duct stenting. (authors)

  7. Patient-specific estimation of detailed cochlear shape from clinical CT images

    DEFF Research Database (Denmark)

    Kjer, H Martin; Fagertun, Jens; Wimmer, Wilhelm

    2018-01-01

    of the detailed patient-specific cochlear shape from CT images. From a collection of temporal bone [Formula: see text]CT images, we build a cochlear statistical deformation model (SDM), which is a description of how a human cochlea deforms to represent the observed anatomical variability. The model is used...... for regularization of a non-rigid image registration procedure between a patient CT scan and a [Formula: see text]CT image, allowing us to estimate the detailed patient-specific cochlear shape. We test the accuracy and precision of the predicted cochlear shape using both [Formula: see text]CT and CT images...

  8. The "flying" bile duct: avulsion of the common bile duct in a plane crash survivor.

    LENUS (Irish Health Repository)

    Mohan, H

    2012-02-01

    Blunt trauma is an unusual cause of extrahepatic bile duct injury. This is a case of a 51-year-old gentleman who sustained a significant seatbelt injury in a plane crash. Laparotomy, performed due to persistent abdominal pain, revealed that the common bile duct (CBD) was completely avulsed from the duodenum. Following insertion of drains and transfer to a hepatobiliary centre, the devascularised CBD was excised and replaced with a roux-en-y hepaticojejunostomy. Necrotic tissue was debrided from the pancreatic head. A persistent bile leak developed from the sub-hepatic drain. Repeat laparotomy revealed a bile leak from small ducts on the liver surface. Ligation of the ducts and bioglue sealing of the area were successfully performed. Subsequent to this a pancreatic fistula developed from the main pancreatic duct, which has since resolved. This unusual case illustrates the need for prompt recognition and early repair to optimise outcomes in traumatic CBD injury.

  9. Duct having oscillatory side wall

    Science.gov (United States)

    Sprouse, Kenneth M.

    2018-04-03

    A pump system includes a particulate consolidator pump that has a pump outlet. A duct is coupled to the pump outlet. The duct has a wall that is coupled with an oscillator. The oscillator is operable to oscillate the wall at a controlled frequency. The controlled frequency is selected with respect to breaking static bridging of particulate in the duct due, at least in part, to consolidation of the particulate from a downstream check valve.

  10. The correlation between the dilated extent of bile duct and gallbladder and low bile duct obstructive jaundice diseases

    International Nuclear Information System (INIS)

    Wang Zhongqiu; Lu Guangming; Li Jieshou; Li Weiqin

    2005-01-01

    Objective: To evaluate the diagnostic value about the dilated extent of bile duct and gallbladder in low biliary obstructive diseases. Methods: CT and ERCP findings of 105 patients with low biliary obstructive disease were retrospectively analyzed. The dilated extent of intrahepatic and extra- hepatic bile duct and gallbladder were classified into seven types: Type I: severe dilatation of intrahepatic and extrahepatic bile duct and gallbladder; Type II: severe dilatation of extrahepatic bile duct and gallbladder and slight dilated intrahapetic bile duct; Type III: severe dilatation of intrahepatic and extrahepatic bile duct without or slight dilatation of gallbladder; Type IV: severe extrahepatic bile duct dilatation without or slight dilatation of intrahepatic bile duct and gallbladder; Type V: severe intrahepatic bile duct dilatation without or with slight dilatation of extrahepatic bile duct and gallbladder; Type VI: severe gallbladder dilatation without or with slight intrahepatic and extra- hepatic bile duct dilatation; Type VII: without or with slight dilatation of intrahepatic and extrahepatic bile duct and gallbladder. The biliary system dilated extent of low biliary obstructive disease on CT and ERCP were compared with results of clinical, operation, and pathology. Results: Thirty-three cases of tumor and 72 cases of non-tumor were proved by clinical and operation in 105 patients with low biliary obstructive disease. In 33 tumor patients, 16 patients were identified as Type I, 10 patients Type II, 4 patients Type III, 1 patient Type IV, 2 patients Type VII. In 72 non-tumor patients, 4 patients were identified as Type I, 4 patients Type II, 9 patients Type III, 33 patients Type IV, 2 patients Type V, 11 patients Type VI, 19 patients Type VII. A large difference between I, II type and III-VII type biliary dilatation existed in tumor and non-tumor group (χ 2 =47.33, P<0.01). Conclusion:Low obstructive biliary diseases are closely correlated with the dilated

  11. [Cochlear implant in patients with congenital malformation of the inner ear].

    Science.gov (United States)

    Wan, Liang-cai; Guo, Meng-he; Qian, Yu-hong; Liu, Shuang-xiu; Zhang, Hong-zheng; Chen, Shuai-jun; Chen, Hao; Gong, Jian

    2009-10-01

    To summarize the clinical experience with multi-channel cochlear implantation in patients with inner ear malformations and evaluate and the outcomes of speech rehabilitation. A retrospective study was conducted in 295 patients receiving cochlear implantation from 1998 to 2007, including 25 patients with large vestibular aqueduct syndrome (LVAS), 9 with Modini malformation, and 5 with common cavity deformity. All the patients received the Nucleus24 cochlear implants. In LVAS cases, 4 had Nucleus 24R (ST) implants, 8 had Contuor implants, 10 had Contuor Advance, and the remaining cases used Nucleus24(M) straight-electrode implants. Severe gusher appeared in 3 cases of LVAS, and perilymph fluctuation were seen in other 15 cases. Four patients with Mondini malformation and 2 with common cavity malformation also experienced severe gusher, but the electrodes were inserted smoothly in all the patients without postoperative facial paralysis or cerebrospinal fluid leakage. The hearing threshold in these patients was similar to that in patients with normal cochlear structure. After speech rehabilitation for over 6 months, the abilities of speech discrimination and spoken language improved in all the cases in comparison with the preoperative lingual functions. Multi-channel cochlear implantation can be performed in patients with inner ear malformation, but should not be attempted in patients with poor cochlear and cochlear nerve development. A comprehensive pre-operative radiographic and audiological evaluation is essential.

  12. Challenges in Improving Cochlear Implant Performance and Accessibility.

    Science.gov (United States)

    Zeng, Fan-Gang

    2017-08-01

    Here I identify two gaps in cochlear implants that have been limiting their performance and acceptance. First, cochlear implant performance has remained largely unchanged, despite the number of publications tripling per decade in the last 30 years. Little has been done so far to address a fundamental limitation in the electrode-to-neuron interface, with the electrode size being a thousand times larger than the neuron diameter while the number of electrodes being a thousand times less. Both the small number and the large size of electrodes produce broad spatial activation and poor frequency resolution that limit current cochlear implant performance. Second, a similarly rapid growth in cochlear implant volume has not produced an expected decrease in unit price in the same period. The high cost contributes to low market penetration rate, which is about 20% in developed countries and less than 1% in developing countries. I will discuss changes needed in both research strategy and business practice to close the gap between prosthetic and normal hearing as well as that between haves and have-nots.

  13. Cochlear implantation in Waardenburg syndrome: The Indian scenario.

    Science.gov (United States)

    Deka, Ramesh Chandra; Sikka, Kapil; Chaturvedy, Gaurav; Singh, Chirom Amit; Venkat Karthikeyan, C; Kumar, Rakesh; Agarwal, Shivani

    2010-10-01

    Children with Waardenburg syndrome (WS) exhibiting normal inner ear anatomy, like those included in our cohort, derive significant benefit from cochlear implantation and results are comparable to those reported for the general population of implanted children. The patient population of WS accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with WS who have undergone cochlear implantation. On retrospective chart review, there were four cases with WS who underwent cochlear implantation. These cases were assessed for age at implantation, clinical and radiological features, operative and perioperative course, and performance outcomes. Auditory perception and speech production ability were evaluated using categories of auditory performance (CAP), meaningful auditory integration scales (MAIS), and speech intelligibility rating (SIR) during the follow-up period. In this group of children with WS, with a minimum follow-up of 12 months, the CAP score ranged from 3 to 5, MAIS from 25 to 30, and SIR was 3. These scores are comparable with those of other cochlear implantees.

  14. Long-term follow-up after choledochojejunostomy for bile duct stones with complex clearance of the bile duct

    NARCIS (Netherlands)

    Gouma, D. J.; Konsten, J.; Soeters, P. B.; Von Meyenfeldt, M.; Obertop, H.

    1989-01-01

    In this retrospective study, the long-term follow-up of patients undergoing choledochojejunostomy (Roux-en-Y) for bile duct stones with complex clearance of the bile duct is evaluated. Bile duct exploration and subsequent choledochojejunostomy (Roux-en-Y) was performed in 43 patients (median age 67

  15. A Plug-and-Play Duct System Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Beach, R. [IBACOS, Inc., Pittsburgh, PA (United States); Dickson, B. [IBACOS, Inc., Pittsburgh, PA (United States); Grisolia, A. [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, A. [IBACOS, Inc., Pittsburgh, PA (United States); Rapport, A. [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-07-01

    This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit in the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.

  16. A Plug-and-Play Duct System Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Beach, Robert [IBACOS, Inc., Pittsburgh, PA (United States); Dickson, Bruce [IBACOS, Inc., Pittsburgh, PA (United States); Grisolia, Anthony [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States); Rapport, Ari [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-07-10

    This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit in the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.

  17. Pneumococcal meningitis post-cochlear implantation: preventative measures.

    Science.gov (United States)

    Wei, Benjamin P C; Shepherd, Robert K; Robins-Browne, Roy M; Clark, Graeme M; O'Leary, Stephen J

    2010-11-01

    Both clinical data and laboratory studies demonstrated the risk of pneumococcal meningitis post-cochlear implantation. This review examines strategies to prevent post-implant meningitis. Medline/PubMed database; English articles after 1980. Search terms: cochlear implants, pneumococcus meningitis, streptococcus pneumonia, immunization, prevention. Narrative review. All articles relating to post-implant meningitis without any restriction in study designs were assessed and information extracted. The presence of inner ear trauma as a result of surgical technique or cochlear implant electrode array design was associated with a higher risk of post-implant meningitis. Laboratory data demonstrated the effectiveness of pneumococcal vaccination in preventing meningitis induced via the hematogenous route of infection. Fibrous sealing around the electrode array at the cochleostomy site, and the use of antibiotic-coated electrode array reduced the risk of meningitis induced via an otogenic route. The recent scientific data support the U.S. Food and Drug Administration recommendation of pneumococcal vaccination for the prevention of meningitis in implant recipients. Nontraumatic cochlear implant design, surgical technique, and an adequate fibrous seal around the cochleostomy site further reduce the risk of meningitis. Copyright © 2010 American Academy of Otolaryngology–Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  18. Multichannel cochlear implantation in the scala vestibuli.

    Science.gov (United States)

    Lin, Karen; Marrinan, Michelle S; Waltzman, Susan B; Roland, J Thomas

    2006-08-01

    Sensorineural hearing loss resulting from otosclerosis, meningitis, chronic otitis media, autoimmune ear disease, and trauma can be associated with partial or total obstruction of the cochlear scalae. Multichannel cochlear implantation may be difficult in a cochlea with an obstructed scala tympani. The purpose of this study is to determine the safety and efficacy of scala tympani electrode insertion. Retrospective chart review. Academic medical center. Eight children and adults with profound sensorineural hearing loss who underwent cochlear implantation with known scala vestibuli electrode array insertion were subjects for this study. Eight study subjects underwent implantation: five with the Nucleus 24RCS (Contour) device and three with the Nucleus 24M device. Imaging findings, operative findings, and age-appropriate speech perception testing. All patients had full electrode insertion. Various obstructive patterns on computed tomography and magnetic resonance imaging were found, and there was a range of speech perception results. All but one patient improved based on age-appropriate monosyllabic word and sentence tests. Scala vestibuli multielectrode insertion is a viable alternative when scala tympani insertion is not possible because of abnormal anatomy or anatomical changes secondary to disease or previous implantation. We will also present an algorithm of options for decision making for implantation when encountering cochlear obstruction and difficult electrode insertion.

  19. SNM holdup assessment of Los Alamos exhaust ducts

    International Nuclear Information System (INIS)

    Marshall, R.S.

    1994-02-01

    Fissile material holdup in glovebox and fume hood exhaust ducting has been quantified for all Los Alamos duct systems. Gamma-based, nondestructive measurements were used to quantify holdup. The measurements were performed during three measurement campaigns. The first campaign, Phase I, provided foot-by-foot, semiquantitative measurement data on all ducting. These data were used to identify ducting that required more accurate (quantitative) measurement. Of the 280 duct systems receiving Phase I measurements, 262 indicated less than 50 g of fissile holdup and 19 indicated fissile holdup of 50 or more grams. Seven duct systems were measured in a second campaign, called Series 1, Phase II. Holdup estimates on these ducts ranged from 421 g of 235 U in a duct servicing a shut-down uranium-machining facility to 39 g of 239 Pu in a duct servicing an active plutonium-processing facility. Measurements performed in the second campaign proved excessively laborious, so a third campaign was initiated that used more efficient instrumentation at some sacrifice in measurement quality. Holdup estimates for the 12 duct systems measured during this third campaign ranged from 70 g of 235 U in a duct servicing analytical laboratories to 1 g of 235 U and 1 g of 239 Pu in a duct carrying exhaust air to a remote filter building. These quantitative holdup estimates support the conclusion made at the completion of the Phase I measurements that only ducts servicing shut-down uranium operations contain about 400 g of fissile holdup. No ventilation ducts at Los Alamos contain sufficient fissile material holdup to present a criticality safety concern

  20. Cochlear Implants and Psychiatric Assessments: a Norrie Disease Case Report.

    Science.gov (United States)

    Jacques, Denis; Dubois, Thomas; Zdanowicz, Nicolas; Gilain, Chantal; Garin, Pierre

    2017-09-01

    It is important to perform psychiatric assessments of adult patients who are candidates for cochlear implants both to screen them for psychiatric disorders and to assess their understanding and compliance with the procedure. Deafness is a factor of difficulty for conducting in-depth psychiatric interviews, but concomitant blindness may make it impossible. After a description of Norrie disease, a rare disease in which blindness and deafness may occur together, we propose a case report of a patient suffering from the disease and who consulted in view of a cochlear implant. Early information on cochlear implants appears to be necessary before total deafness occurs in patients suffering from Norrie disease. An inventory of digital communication tools that can be used by the patient is also highly valuable. Research should be supported for a more systematic use of psychiatric assessments prior to cochlear implants. In the special case of Norrie disease, we recommend early screening for mental retardation and related psychotic disorders and, depending on the patient's level of understanding, preventive information on the benefits and limits of cochlear implants before total deafness occurs.

  1. Nasopalatine duct cyst: A case report

    Directory of Open Access Journals (Sweden)

    Saikrishna Pasupuleti

    2015-01-01

    Full Text Available Nasopalatine duct cyst (NPDC is the most common non-odontogenic cyst of oral cavity. Clinically, Nasopalatine duct cyst manifests as an asymptomatic swelling of the palate or the upper lip. Radiographically, it is seen as a heart-shaped radiolucency and can be confused with periapical pathology. The aim of this article is to report a case of a nasopalatine duct cyst in a 36-year-old patient which was misinterpreted for a periapical cyst. Diagnosis of a Nasopalatine duct cyst can be given through clinical, radiographical, and histopathological examination.

  2. Radiologic imaging of bile duct changes by clonorchiasis

    International Nuclear Information System (INIS)

    Kim, Myung Joon; Yoo, Hyung Sik; Lee, Jong Tae; Jung, Soon Hee

    1988-01-01

    The changes of the bile ducts were reviewed retrospectively in 38 patients of clonorchiasis by ultrasonography and/or CT. Diagnosis was made in 13 patients by cholecystectomy and exploration of the common bile duct, another 2 patients by segmentectomy and wedge resection of the liver, and 23 patients by stool examination. 14 of 36 cases done ultrasonography showed the parallel channel sign, and small nodular echoes around the dilated bile ducts. And 3 cases showed the echoes of worm of clonorchis sinensis in the common bile duct. 22 of 36 cases showed the parallel channel signs only. All cases (11) done CT showed diffuse dilatation of the peripheral bile ducts. 5 of 11 cases showed ring or tubular contrast enhancement around the dilated bile ducts. In 2 cases of liver resection, the bile ducts showed adenomatous hyperplasia and severe periductal fibrosis. Proliferation of blood vessels and infiltration of inflammatory cells were also seen. So we consider that the increased echoes of the bile duct wall, small nodular echoes around the bile ducts were attributed to the bile duct dilatation, severe adenomatous hyperplasia and periductal fibrosis. The ring or tubular contrast enhancement of the dilated bile ducts seems to be caused by the marked periductal inflammation resulting in capillary proliferation and the periductal fibrosis.

  3. Radiologic imaging of bile duct changes by clonorchiasis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myung Joon; Yoo, Hyung Sik; Lee, Jong Tae; Jung, Soon Hee [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-10-15

    The changes of the bile ducts were reviewed retrospectively in 38 patients of clonorchiasis by ultrasonography and/or CT. Diagnosis was made in 13 patients by cholecystectomy and exploration of the common bile duct, another 2 patients by segmentectomy and wedge resection of the liver, and 23 patients by stool examination. 14 of 36 cases done ultrasonography showed the parallel channel sign, and small nodular echoes around the dilated bile ducts. And 3 cases showed the echoes of worm of clonorchis sinensis in the common bile duct. 22 of 36 cases showed the parallel channel signs only. All cases (11) done CT showed diffuse dilatation of the peripheral bile ducts. 5 of 11 cases showed ring or tubular contrast enhancement around the dilated bile ducts. In 2 cases of liver resection, the bile ducts showed adenomatous hyperplasia and severe periductal fibrosis. Proliferation of blood vessels and infiltration of inflammatory cells were also seen. So we consider that the increased echoes of the bile duct wall, small nodular echoes around the bile ducts were attributed to the bile duct dilatation, severe adenomatous hyperplasia and periductal fibrosis. The ring or tubular contrast enhancement of the dilated bile ducts seems to be caused by the marked periductal inflammation resulting in capillary proliferation and the periductal fibrosis.

  4. Costs involved in using a cochlear implant in South Africa

    Directory of Open Access Journals (Sweden)

    Gillian Robyn Kerr

    2012-12-01

    Full Text Available Cochlear implantation is an expensive but effective lifelong intervention for individuals with a severe-to-profound hearing loss. The primary aim of this study was to survey the short- and long-term costs of cochlear implantation. Individuals (N=154 using cochlear implants obtained from the University of Stellenbosch-Tygerberg Hospital Cochlear Implant Unit in Cape Town, South Africa were surveyed using a questionnaire and patient record review. The questionnaire used a combination of closed and open-ended questions to gather both quantitative and qualitative information. Costs were categorised as short- and long-term costs. All costs were converted to constant rands (June 2010 using the Consumer Price Index to allow for comparison in real terms over time. In the first 10 years of implantation the average estimated costs incurred by adults totalled R379 626, and by children R455 225. The initial purchase of the implant system was the most substantial cost, followed by upgrading of the processor. Travel and accommodation costs peaked in the first 2 years. On average the participants spent R2 550 per year on batteries and spares. Rehabilitation for children cost an average of R7 200. Insurance costs averaged R4 040 per year, and processor repairs R3 000 each. In addition to the upfront expense of obtaining the cochlear implant system, individuals using a cochlear implant in South Africa should be prepared for the long-term costs of maintenance, accessing the unit, support services and additional costs associated with use. Knowledge of these costs is important to ensure that individuals are successful users of their cochlear implants in the long term.

  5. Is cochlear implantation a good treatment method for profoundly deafened elderly?

    Directory of Open Access Journals (Sweden)

    Lachowska M

    2013-10-01

    Full Text Available Magdalena Lachowska, Agnieszka Pastuszka, Paulina Glinka, Kazimierz Niemczyk Department of Otolaryngology, Hearing Implant Center, Medical University of Warsaw, Warsaw, Poland Purpose: To assess the benefits of cochlear implantation in the elderly. Patients and methods: A retrospective analysis of 31 postlingually deafened elderly (≥60 years of age with unilateral cochlear implants was conducted. Audiological testing included preoperative and postoperative pure-tone audiometry and a monosyllabic word recognition test presented from recorded material in free field. Speech perception tests included Ling's six sound test (sound detection, discrimination, and identification, syllable discrimination, and monosyllabic and multisyllabic word recognition (open set without lip-reading. Everyday life benefits from cochlear implantation were also evaluated. Results: The mean age at the time of cochlear implantation was 72.4 years old. The mean post-implantation follow-up time was 2.34 years. All patients significantly improved their audiological and speech understanding performances. The preoperative mean pure-tone average threshold for 500 Hz, 1,000 Hz, 2,000 Hz, and 4,000 Hz was 110.17 dB HL. Before cochlear implantation, all patients scored 0% on the monosyllabic word recognition test in free field at 70 dB SPL intensity level. The postoperative pure-tone average was 37.14 dB HL (the best mean threshold was 17.50 dB HL, the worst was 58.75 dB HL. After the surgery, mean monosyllabic word recognition reached 47.25%. Speech perception tests showed statistically significant improvement in speech recognition. Conclusion: The results of this study showed that cochlear implantation is indeed a successful treatment for improving speech recognition and offers a great help in everyday life to deafened elderly patients. Therefore, they can be good candidates for cochlear implantation and their age alone should not be a relevant or excluding factor when choosing

  6. The long-term concerns post cochlear implantation as experienced ...

    African Journals Online (AJOL)

    Background. Cochlear implantation aims to provide an effective means of spoken communication for prelingually deaf children. However, studies in this field are mostly clinically orientated, with little focus on the experiences and long-term concerns of families post cochlear implantation (CI). Objective. To describe the ...

  7. A software tool for analyzing multichannel cochlear implant signals.

    Science.gov (United States)

    Lai, Wai Kong; Bögli, Hans; Dillier, Norbert

    2003-10-01

    A useful and convenient means to analyze the radio frequency (RF) signals being sent by a speech processor to a cochlear implant would be to actually capture and display them with appropriate software. This is particularly useful for development or diagnostic purposes. sCILab (Swiss Cochlear Implant Laboratory) is such a PC-based software tool intended for the Nucleus family of Multichannel Cochlear Implants. Its graphical user interface provides a convenient and intuitive means for visualizing and analyzing the signals encoding speech information. Both numerical and graphic displays are available for detailed examination of the captured CI signals, as well as an acoustic simulation of these CI signals. sCILab has been used in the design and verification of new speech coding strategies, and has also been applied as an analytical tool in studies of how different parameter settings of existing speech coding strategies affect speech perception. As a diagnostic tool, it is also useful for troubleshooting problems with the external equipment of the cochlear implant systems.

  8. Libyan cochlear implant programme: achievements, difficulties, and future goals

    Directory of Open Access Journals (Sweden)

    Samya El-Ogbi

    2011-05-01

    Full Text Available Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI 100 devices. Thirty-four (91.9% of these patients were children, whilst three (8.1% were adults. Combined, congenital hearing loss (56.8% and perinatal/neonatal (29.7% were the two main aetiological factors in children. Seventeen patients (45.9% had a positive family history of deafness. Sixteen patients (43.2% were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies.

  9. Libyan cochlear implant programme: achievements, difficulties, and future goals.

    Science.gov (United States)

    Salamat, Ali; Esriti, Anwer; Ehtuish, Asia; El-Ogbi, Samya

    2011-01-01

    Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATA(TI) (100) devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) were adults. Combined, congenital hearing loss (56.8%) and perinatal/neonatal (29.7%) were the two main aetiological factors in children. Seventeen patients (45.9%) had a positive family history of deafness. Sixteen patients (43.2%) were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies.

  10. Effect of duct geometry on Wells turbine performance

    International Nuclear Information System (INIS)

    Shaaban, S.; Abdel Hafiz, A.

    2012-01-01

    Highlights: ► A Wells turbine duct design in the form of venturi duct is proposed and investigated. ► Optimum duct geometry is identified. ► Up to 14% increase of the turbine power can be achieved using the optimized duct geometry. ► Up to 9% improve of the turbine efficiency is attained by optimizing the turbine duct geometry. ► The optimized duct geometry results in tangible delay of the turbine stalling point. - Abstract: Wells turbines can represent important source of renewable energy for many countries. An essential disadvantage of Wells turbines is their low aerodynamic efficiency and consequently low power produced. In order to enhance the Wells turbine performance, the present research work proposes the use of a symmetrical duct in the form of a venturi tube with turbine rotor located at throat. The effects of duct area ratio and duct angle are investigated in order to optimize Wells turbine performance. The turbine performance is numerically investigated by solving the steady 3D incompressible Reynolds Averaged Navier–Stocks equation (RANS). A substantial improve of the turbine performance is achieved by optimizing the duct geometry. Increasing both the duct area ratio and duct angle increase the acceleration and deceleration upstream and downstream the rotor respectively. The accelerating flow with thinner boundary layer thickness upstream the rotor reduces the flow separation on the rotor suction side. The downstream diffuser reduces the interaction between tip leakage flow and blade suction side. Up to 14% increase in turbine power and 9% increase in turbine efficiency are achieved by optimizing the duct geometry. On other hand, a tangible delay of the turbine stall point is also detected.

  11. Facial nerve stimulation outcomes after cochlear implantation with cochlear-facial dehiscence

    Directory of Open Access Journals (Sweden)

    Christina H. Fang, MD

    2017-06-01

    Conclusion: Cochlear-facial dehiscence can predispose patients to post-implant FNS. Prior temporal bone irradiation may carry a higher risk of FNS. We recommend scrutiny for CFD in CTs of CI candidates and appropriate risk counseling for FNS if CFD is discovered and more frequent monitoring for FNS by audiology.

  12. Anomalous facial nerve canal with cochlear malformations.

    Science.gov (United States)

    Romo, L V; Curtin, H D

    2001-05-01

    Anteromedial "migration" of the first segment of the facial nerve canal has been previously identified in a patient with a non-Mondini-type cochlear malformation. In this study, several patients with the same facial nerve canal anomaly were reviewed to assess for the association and type of cochlear malformation. CT scans of the temporal bone of 15 patients with anteromedial migration of the first segment of the facial nerve canal were collected from routine departmental examinations. In seven patients, the anomalous course was bilateral, for a total of 22 cases. The migration was graded relative to normal as either mild/moderate or pronounced. The cochlea in each of these cases was examined for the presence and size of the basilar, second, and apical turns. The turns were either absent, small, normal, or enlarged. The CT scans of five patients with eight Mondini malformations were examined for comparison. The degree of the facial nerve migration was pronounced in nine cases and mild/moderate in 13. All 22 of these cases had associated cochlear abnormalities of the non-Mondini variety. These included common cavity anomalies with lack of definition between the cochlea and vestibule (five cases), cochleae with enlarged basilar turns and absent second or third turns (five cases), and cochleae with small or normal basilar turns with small or absent second or third turns (12 cases). None of the patients with Mondini-type cochlear malformations had anteromedial migration of the facial nerve canal. Anteromedial migration of the facial nerve canal occurs in association with some cochlear malformations. It did not occur in association with the Mondini malformations. A cochlea with a Mondini malformation, being similar in size to a normal cochlea, may physically prohibit such a deviation in course.

  13. Microphone directionality, pre-emphasis filter, and wind noise in cochlear implants.

    Science.gov (United States)

    Chung, King; McKibben, Nicholas

    2011-10-01

    Wind noise can be a nuisance or a debilitating masker for cochlear implant users in outdoor environments. Previous studies indicated that wind noise at the microphone/hearing aid output had high levels of low-frequency energy and the amount of noise generated is related to the microphone directionality. Currently, cochlear implants only offer either directional microphones or omnidirectional microphones for users at-large. As all cochlear implants utilize pre-emphasis filters to reduce low-frequency energy before the signal is encoded, effective wind noise reduction algorithms for hearing aids might not be applicable for cochlear implants. The purposes of this study were to investigate the effect of microphone directionality on speech recognition and perceived sound quality of cochlear implant users in wind noise and to derive effective wind noise reduction strategies for cochlear implants. A repeated-measure design was used to examine the effects of spectral and temporal masking created by wind noise recorded through directional and omnidirectional microphones and the effects of pre-emphasis filters on cochlear implant performance. A digital hearing aid was programmed to have linear amplification and relatively flat in-situ frequency responses for the directional and omnidirectional modes. The hearing aid output was then recorded from 0 to 360° at flow velocities of 4.5 and 13.5 m/sec in a quiet wind tunnel. Sixteen postlingually deafened adult cochlear implant listeners who reported to be able to communicate on the phone with friends and family without text messages participated in the study. Cochlear implant users listened to speech in wind noise recorded at locations that the directional and omnidirectional microphones yielded the lowest noise levels. Cochlear implant listeners repeated the sentences and rated the sound quality of the testing materials. Spectral and temporal characteristics of flow noise, as well as speech and/or noise characteristics before

  14. Cochlear implantation in autistic children with profound sensorineural hearing loss.

    Science.gov (United States)

    Lachowska, Magdalena; Pastuszka, Agnieszka; Łukaszewicz-Moszyńska, Zuzanna; Mikołajewska, Lidia; Niemczyk, Kazimierz

    2016-11-19

    Cochlear implants have become the method of choice for the treatment of severe-to-profound hearing loss in both children and adults. Its benefits are well documented in the pediatric and adult population. Also deaf children with additional needs, including autism, have been covered by this treatment. The aim of this study was to assess the benefits from cochlear implantation in deafened children with autism as the only additional disability. This study analyzes data of six children. The follow-up time was at least 43 months. The following data were analyzed: medical history, reaction to music and sound, Ling's six sounds test, onomatopoeic word test, reaction to spoken child's name, response to requests, questionnaire given to parents, sound processor fitting sessions and data. After cochlear implantation each child presented other communication skills. In some children, the symptoms of speech understanding were observed. No increased hyperactivity associated with daily use cochlear implant was observed. The study showed that in autistic children the perception is very important for a child's sense of security and makes contact with parents easier. Our study showed that oral communication is not likely to be a realistic goal in children with cochlear implants and autism. The implantation results showed benefits that varied among those children. The traditional methods of evaluating the results of cochlear implantation in children with autism are usually insufficient to fully assess the functional benefits. These benefits should be assessed in a more comprehensive manner taking into account the limitations of communication resulting from the essence of autism. It is important that we share knowledge about these complex children with cochlear implants. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  15. Conductive component after cochlear implantation in patients with residual hearing conservation.

    Science.gov (United States)

    Chole, Richard A; Hullar, Timothy E; Potts, Lisa G

    2014-12-01

    Changes in auditory thresholds following cochlear implantation are generally assumed to be due to damage to neural elements. Theoretical studies have suggested that placement of a cochlear implant can cause a conductive hearing loss. Identification of a conductive component following cochlear implantation could guide improvements in surgical techniques or device designs. The purpose of this study is to characterize new-onset conductive hearing losses after cochlear implantation. In a prospective study, air- and bone-conduction audiometric testing were completed on cochlear implant recipients. An air-bone gap equal to or greater than 15 dB HL at 2 frequencies determined the presence of a conductive component. Of the 32 patients with preoperative bone-conduction hearing, 4 patients had a new-onset conductive component resulting in a mixed hearing loss, with air-conduction thresholds ranging from moderate to profound and an average air-bone gap of 30 dB HL. One had been implanted through the round window, 2 had an extended round window, and 1 had a separate cochleostomy. Loss of residual hearing following cochlear implantation may be due in part to a conductive component. Identifying the mechanism for this conductive component may help minimize hearing loss. Postoperative hearing evaluation should measure both air- and bone-conduction thresholds.

  16. [Applied anatomy of scala tympani inlet related to cochlear implantation].

    Science.gov (United States)

    Zou, Tuanming; Guo, Menghe; Zhang, Hongzheng; Shu, Fan; Xie, Nanping

    2012-06-01

    To investigate the related parameters of the temporal bone structure for determining the position of implanting electrode into the scala tympani in cochlear implantation surgery through the facial recess and epitympanum approach. In a surgical simulation experiment, 20 human temporal bones were studied and measured to determine the related parameters of the temporal bone structure. The distance 5.91∓0.29 mm between the short process of the incus and the round window niche, 2.11∓0.18 mm between the stapes and the round window niche, 6.70∓0.19 mm between the facial nerve in the perpendicular paragraph and the round window niche, 2.22∓0.21 mm from the pyramidal eminence to the round window, and 2.16∓0.14 mm between the stapes and the round window. The minimal distance between the implanting electrode and the vestibular window was 2.12∓0.19 mm. The distance between the cochleariform process and the round window niche was 3.79∓0.17 mm. The position of the cochlear electrode array insertion into the second cochlear turn was 2.25∓0.13 mm under the stapes. The location of the cochlear electrode array insertion into the second cochlear turn was 2.28∓0.20 mm inferior to the pyramidal eminence. These parameters provide a reference value to determine the different positions of cochlear electrode array insertion into the scale tympani in different patients.

  17. Cochlear Implantation in Siblings With Refsum's Disease.

    Science.gov (United States)

    Stähr, Kerstin; Kuechler, Alma; Gencik, Martin; Arnolds, Judith; Dendy, Meaghan; Lang, Stephan; Arweiler-Harbeck, Diana

    2017-08-01

    Whether the origin of severe hearing loss in Refsum's syndrome is caused by cochlear impairment or retrocochlear degeneration remains unclear. This case report aims to investigate hearing performance before and after cochlear implantation to shed light on this question. Also, identification of new mutations causing Refsum's syndrome would be helpful in generating additional means of diagnosis. A family of 4 individuals was subjected to genetic testing. Two siblings (56 and 61 years old) suffered from severe hearing and vision loss and received bilateral cochlear implants. Genetic analysis, audiological outcome, and clinical examinations were performed. One new mutation in the PHYH gene (c.768del63bp) causing Refsum's disease was found. Preoperative distortion product otoacoustic emissions (DPAOEs) were absent. Postoperative speech perception in Freiburger speech test was 100% for bisyllabic words and 85% (patient No. 1) and 65% (patient No. 2), respectively, for monosyllabic words. Five years after implantation, speech perception remained stable for bisyllabic words but showed decreasing capabilities for monosyllabic words. A new mutation causing Refsum's disease is presented. Cochlear implantation in case of severe hearing loss leads to an improvement in speech perception and should be recommended for patients with Refsum's disease, especially when the hearing loss is combined with a severe loss of vision. Decrease of speech perception in the long-term follow-up could indicate an additional retrocochlear degeneration.

  18. Are parents of children with cochlear implants coping?: research ...

    African Journals Online (AJOL)

    Many variables must be considered during the evaluation and rehabilitation of children for cochlear implantation, one of which is parental influence (for the duration of this report the parents, caregivers and guardians of children with cochlear implants and / or hearing impairments will be referred to as 'parents'). The aim of ...

  19. ITER L 6 equatorial maintenance duct remote handling study

    International Nuclear Information System (INIS)

    Millard, J.

    1996-09-01

    The status and conclusions of a preliminary study of equatorial maintenance duct remote handling is reported. Due to issues with the original duct design a significant portion of the study had to be refocused on equatorial duct layout studies. The study gives an overview of some of the options for design of these ducts and the impact of the design on the equipment to work in the duct. To develop a remote handling concept for creating access through the ducts the following design tasks should be performed: define the operations sequences for equatorial maintenance duct opening and closing; review the remote handling requirements for equatorial maintenance duct opening and closing; design concept for door and pipe handling equipment and to propose preliminary procedures for material handling outsides the duct. 35 figs

  20. Spectral measurements of gamma radiation streaming through ducts

    International Nuclear Information System (INIS)

    Meenakshisundaram, P.K.; Bhatnagar, V.M.; Raghunath, V.M.; Gopinath, D.V.

    1979-01-01

    The paper presents the spectral measurements of gamma radiation streaming through multi-legged rectangular concrete ducts for cesium-137 and cobald-60 sources. Effect of lead lining the inner surface of the duct on the streaming radiation spectrum and optimization of liner thickness for minimum streaming radiation dose have been studied. For three-legged ducts, a comparative analysis of lead lining the entire duct as against lining any one or both the corners of the duct is reported. It is seen that lead lining any one of the corners would reduce the streaming radiation dose by a factor of 5 to 12. Lining both the corners which is nearly as effective as lining the entire duct reduces the dose by a factor of 16 to 60 depending on the soruce energy and duct dimensions. (orig.)

  1. Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts

    Energy Technology Data Exchange (ETDEWEB)

    Beal, D.; McIlvaine , J.; Fonorow, K.; Martin, E.

    2011-11-01

    This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. This document illustrates guidelines for the efficient installation of interior duct systems in new housing. Interior ducts result from bringing the duct work inside a home's thermal and air barrier. Architects, designers, builders, and new home buyers should thoroughly investigate any opportunity for energy savings that is as easy to implement during construction, such as the opportunity to construct interior duct work. In addition to enhanced energy efficiency, interior ductwork results in other important advantages, such as improved indoor air quality, increased system durability and increased homeowner comfort. While the advantages of well-designed and constructed interior duct systems are recognized, the implementation of this approach has not gained a significant market acceptance. This guideline describes a variety of methods to create interior ducts including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. As communication of the intent of an interior duct system, and collaboration on its construction are paramount to success, this guideline details the critical design, planning, construction, inspection, and verification steps that must be taken. Involved in this process are individuals from the design team; sales/marketing team; and mechanical, insulation, plumbing, electrical, framing, drywall and solar contractors.

  2. A case report: the first successful cochlear implant in Uganda.

    African Journals Online (AJOL)

    A case report: the first successful cochlear implant in Uganda. Richard Byaruhanga1, J. ... The patient was a 23 year old male whose presenting com- plaint was inability to .... Custom Sound by Cochlear (the company that manu- factures the ...

  3. Cochlear pathology in chronic suppurative otitis media.

    Science.gov (United States)

    Walby, A P; Barrera, A; Schuknecht, H F

    1983-01-01

    Chronic suppurative otitis media (COM) is reported to cause elevation of bone-conduction thresholds either by damage to cochlear sensorineural structures or by alteration in the mechanics of sound transmission in the ear. A retrospective study was made of the medical records of 87 patients with unilateral uncomplicated COM to document that abnormality in bone conduction does exist. In a separate study the cochlear pathology in 12 pairs of temporal bones with unilateral COM was studied by light microscopy. Infected ears showed higher than normal mean bone-conduction thresholds by amounts ranging from 1 dB at 500 Hz to 9.5 dB at 4,000 Hz. The temporal bones showed no greater loss of specialized sensorineural structures in infected ears than in normal control ears. Because there is no evidence that COM caused destruction of hair cells or cochlear neurons, alteration in the mechanics of sound transmission becomes a more plausible explanation for the hearing losses.

  4. Financial Aspects of Bile Duct Injuries.

    Science.gov (United States)

    Palaz Alı, Ozgkıour; Ibis, Abdil Cem; Gurtekin, Basak

    2017-11-04

    BACKGROUND Major bile duct injury is the most worrisome complication of cholecystectomy. There is no detailed data about the incidence or treatment-related costs of bile duct injuries in Turkey. We aimed to determine prevalence and therapeutic costs of patients with major biliary duct injuries managed in our department, and further estimate a projection of these parameters at the national level. MATERIAL AND METHODS All patients admitted due to bile duct injury during cholecystectomy from 2011 to 2014 were included. Healthcare costs were calculated by summing of their all treatment-related costs in Istanbul Medical Faculty. We collected 2014-2015 data on number of patients diagnosed with cholecystitis in Turkey, the number of cholecystectomies, and the number of the interventions performed following these initial surgeries, which were obtained from the Turkish Social Security Institution. RESULTS Forty-nine patients were enrolled and bilioenteric diversion was performed in 39 patients: 20.4% of patients had Bismuth II, 38.8% had Bismuth III, and 40.8% had Bismuth IV biliary stricture. Comparison of stricture types with total costs, days of hospitalization, and outpatient clinic costs revealed significant differences. Mean total cost of corrective surgeries was 9199 TRY. We estimated that 1.5% to 2.4% of patients who underwent cholecystectomy in Turkey have bile duct injury (including 0.3% with major bile duct injury). CONCLUSIONS New preventive strategies should be used to avoid bile duct injuries, which have a huge financial impact on the national economy.

  5. Microanatomy of the cochlear hook

    Science.gov (United States)

    Kwan, Changyow Claire; Tan, Xiaodong; Stock, Stuart R.; Soriano, Carmen; Xiao, Xianghui; Richter, Claus-Peter

    2017-09-01

    Communication among humans occurs through coding and decoding of acoustic information. The inner ear or cochlea acts as a frequency analyzer and divides the acoustic signal into small frequency bands, which are processed at different sites along the cochlea. The mechano-electrical conversion is accomplished by the soft tissue structures in the cochlea. While the anatomy for most of the cochlea has been well described, a detailed description of the very high frequency and vulnerable cochlear hook region is missing. To study the cochlear hook, mice cochleae were imaged with synchrotron radiation and high-resolution reconstructions have been made from the tomographic scans. This is the first detailed description of the bony and soft tissues of the hook region of the mammalian cochlea.

  6. Vitellointestinal Duct Anomalies in Infancy.

    Science.gov (United States)

    Kadian, Yogender Singh; Verma, Anjali; Rattan, Kamal Nain; Kajal, Pardeep

    2016-01-01

    Vitellointestinal duct (VID) or omphalomesenteric duct anomalies are secondary to the persistence of the embryonic vitelline duct, which normally obliterates by weeks 5-9 of intrauterine life. This is a retrospective analysis of a total of 16 patients of symptomatic remnants of vitellointestinal duct from period of Jan 2009 to May 2013. Male to female ratio (M:F) was 4.3:1 and mean age of presentation was 2 months and their mode of presentation was: patent VID in 9 (56.25%) patients, umbilical cyst in 2(12.25%), umbilical granuloma in 2 (12.25%), and Meckel diverticulum as content of hernia sac in obstructed umbilical hernia in 1 (6.25%) patient. Two patients with umbilical fistula had severe electrolyte disturbance and died without surgical intervention. Persistent VID may have varied presentations in infancy. High output umbilical fistula and excessive bowel prolapse demand urgent surgical intervention to avoid morbidity and mortality.

  7. Emotion Understanding in Deaf Children with a Cochlear Implant

    Science.gov (United States)

    Wiefferink, Carin H.; Rieffe, Carolien; Ketelaar, Lizet; De Raeve, Leo; Frijns, Johan H. M.

    2013-01-01

    It is still largely unknown how receiving a cochlear implant affects the emotion understanding in deaf children. We examined indices for emotion understanding and their associations with communication skills in children aged 2.5-5 years, both hearing children (n = 52) and deaf children with a cochlear implant (n = 57). 2 aspects of emotion…

  8. Cholangiographic evaluation of bile duct carcinoma

    International Nuclear Information System (INIS)

    Nichols, D.A.; MacCarty, R.L.; Gaffey, T.A.

    1983-01-01

    Cholangiograms and clinical histories of 82 patients with biopsy-proved bile duct carcinoma were reviewed. The carcinomas were classified according to morphologic findings and clinical outcome. Ulcerative colitis and antecedent inflammatory disease of the biliary tree, particularly primary sclerosing cholangitis, seem to predispose to the development of bile duct carcinoma. Focal stenotic lesions were the most common morphologic type (62/82). Polypoid carcinomas and diffuse sclerosing carcinomas were less common and of about equal frequency. Prognosis was best for patients with polypoid carcinomas and worst for those with diffuse sclerosing carcinomas. In 69 cases (84%), the tumors involved the intrahepatic or proximal extrahepatic ducts, makin curative resection difficult or impossible. Patients with carcinomas limited to the more distal extrahepatic bile ducts had a longer average survival and a higher probability of surgical cure. Proper management of patients with bile duct carcinoma requires a complete and accurate cholangiographic evaluation of the morphology, location, and extent of the disease

  9. COCHLEAR IMPLANTATION IN A PATIENT WITH USHER'S SYNDROME

    OpenAIRE

    Derinsu, Ufuk; Ciprut, Ayca

    2016-01-01

    Usher's Syndrome is an autosomal recessive disorder characterized by congenital hearing loss and retinitis pigmentosa. Usher’s Syndrome patients with severe to profound sensorineural hearing loss can be considered as candidates for cochlear implantation.This case study reports a deaf-blind with Usher's Syndrome who received a cochlear implant, the audiological evaluation is presented and the therapy sessions are discussed. The patient demonstrated good performance overtime after the...

  10. Auditory Mechanics of the Tectorial Membrane and the Cochlear Spiral

    Science.gov (United States)

    Gavara, Núria; Manoussaki, Daphne; Chadwick, Richard S.

    2012-01-01

    Purpose of review This review is timely and relevant since new experimental and theoretical findings suggest that cochlear mechanics from the nanoscale to the macroscale are affected by mechanical properties of the tectorial membrane and the spiral shape. Recent findings Main tectorial membrane themes covered are i) composition and morphology, ii) nanoscale mechanical interactions with the outer hair cell bundle, iii) macroscale longitudinal coupling, iv) fluid interaction with inner hair cell bundles, v) macroscale dynamics and waves. Main cochlear spiral themes are macroscale low-frequency energy focusing and microscale organ of Corti shear gain. Implications Findings from new experimental and theoretical models reveal exquisite sensitivity of cochlear mechanical performance to tectorial membrane structural organization, mechanics, and its positioning with respect to hair bundles. The cochlear spiral geometry is a major determinant of low frequency hearing. Suggestions are made for future research directions. PMID:21785353

  11. [Pre-operation evaluation and intra-operation management of cochlear implantation].

    Science.gov (United States)

    Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning

    2004-10-01

    To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.

  12. Music Therapy for Preschool Cochlear Implant Recipients

    Science.gov (United States)

    Gfeller, Kate; Driscoll, Virginia; Kenworthy, Maura; Van Voorst, Tanya

    2010-01-01

    This paper provides research and clinical information relevant to music therapy for preschool children who use cochlear implants (CI). It consolidates information from various disciplinary sources regarding (a) cochlear implantation of young prelingually-deaf children (~age 2-5), (b) patterns of auditory and speech-language development, and (c) research regarding music perception of children with CIs. This information serves as a foundation for the final portion of the article, which describes typical music therapy goals and examples of interventions suitable for preschool children. PMID:23904691

  13. Effects of residual hearing on cochlear implant outcomes in children: A systematic-review.

    Science.gov (United States)

    Chiossi, Julia Santos Costa; Hyppolito, Miguel Angelo

    2017-09-01

    to investigate if preoperative residual hearing in prelingually deafened children can interfere on cochlear implant indication and outcomes. a systematic-review was conducted in five international databases up to November-2016, to locate articles that evaluated cochlear implantation in children with some degree of preoperative residual hearing. Outcomes were auditory, language and cognition performances after cochlear implant. The quality of the studies was assessed and classified according to the Oxford Levels of Evidence table - 2011. Risk of biases were also described. From the 30 articles reviewed, two types of questions were identified: (a) what are the benefits of cochlear implantation in children with residual hearing? (b) is the preoperative residual hearing a predictor of cochlear implant outcome? Studies ranged from 04 to 188 subjects, evaluating populations between 1.8 and 10.3 years old. The definition of residual hearing varied between studies. The majority of articles (n = 22) evaluated speech perception as the outcome and 14 also assessed language and speech production. There is evidence that cochlear implant is beneficial to children with residual hearing. Preoperative residual hearing seems to be valuable to predict speech perception outcomes after cochlear implantation, even though the mechanism of how it happens is not clear. More extensive researches must be conducted in order to make recommendations and to set prognosis for cochlear implants based on children preoperative residual hearing. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Hearing Preservation in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Priscila Carvalho Miranda

    2014-01-01

    Full Text Available In the past, it was thought that hearing loss patients with residual low-frequency hearing would not be good candidates for cochlear implantation since insertion was expected to induce inner ear trauma. Recent advances in electrode design and surgical techniques have made the preservation of residual low-frequency hearing achievable and desirable. The importance of preserving residual low-frequency hearing cannot be underestimated in light of the added benefit of hearing in noisy atmospheres and in music quality. The concept of electrical and acoustic stimulation involves electrically stimulating the nonfunctional, high-frequency region of the cochlea with a cochlear implant and applying a hearing aid in the low-frequency range. The principle of preserving low-frequency hearing by a “soft surgery” cochlear implantation could also be useful to the population of children who might profit from regenerative hair cell therapy in the future. Main aspects of low-frequency hearing preservation surgery are discussed in this review: its brief history, electrode design, principles and advantages of electric-acoustic stimulation, surgical technique, and further implications of this new treatment possibility for hearing impaired patients.

  15. Congenitally Deafblind Children and Cochlear Implants: Effects on Communication

    Science.gov (United States)

    Dammeyer, Jesper

    2009-01-01

    There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on CI in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of five congenitally deafblind children who received cochlear implants between 2.2 and 4.2…

  16. Reduction in spread of excitation from current focusing at multiple cochlear locations in cochlear implant users.

    Science.gov (United States)

    Padilla, Monica; Landsberger, David M

    2016-03-01

    Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Audiological outcomes of cochlear implantation in Waardenburg Syndrome

    Directory of Open Access Journals (Sweden)

    Magalhães, Ana Tereza de Matos

    2014-01-01

    Full Text Available Introduction: The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss. Aim: To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations. Method: This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed. Results: During this period, 806 patients received a cochlear implant and 10 of these (1.2% were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24® implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor. Conclusion: Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.

  18. Audiological outcomes of cochlear implantation in Waardenburg Syndrome.

    Science.gov (United States)

    Magalhães, Ana Tereza de Matos; Samuel, Paola Angélica; Goffi-Gomez, Maria Valeria Schimdt; Tsuji, Robinson Koji; Brito, Rubens; Bento, Ricardo Ferreira

    2013-07-01

     The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss.  To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations.  This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed.  During this period, 806 patients received a cochlear implant and 10 of these (1.2%) were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24(®) implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor.  Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.

  19. Barriers to pediatric cochlear implantation: A parental survey.

    Science.gov (United States)

    Yang, Charles Q; Reilly, Brian K; Preciado, Diego A

    2018-01-01

    This study aims to (1) determine barriers in the pediatric cochlear implantation process specific to publicly insured patients, wherein delayed implantation has been reported, and (2) compare the perceived barriers between publicly and privately insured patients. Tertiary care cochlear implantation center at academic pediatric hospital. Cross-sectional survey, retrospective chart review. The validated, 39 item Barriers to Care Questionnaire was administered to the parents of 80 recipients of cochlear implantation by two surgeons between 2013 and 2016. Survey results and diagnosis to implant interval were compared based on public or private insurance status. Two-tailed Mann-Whitney and Fisher's exact test was used for statistical analysis. Of 110 cochlear implants, 27 of 80 (34%) English-speaking parents completed the survey. 15 were privately insured and 12 were publicly insured. 23 of 27 respondents received cochlear implantation for pre-lingual sensorineural hearing loss. Publicly insured patients had significantly longer median time from diagnosis to implant than privately insured (19 vs. 8 mo, p = 0.01). The three worst scoring barrier categories for privately insured families in order were Pragmatics, Expectations, and Marginalization, whereas for publicly insured families it was Pragmatics, Skills, and Expectations. The worst scoring question for privately insured patients was "Having to take time off work". For the publicly insured, it was "Lack of communication." Privately insured patients reported more barriers on the Barriers to Care Questionnaire than publicly insured patients did. Although pragmatics was the worst-scoring barrier category for both groups, difficulties found on the survey ranked differently for each group. This information can help providers address disparities and access barriers for vulnerable patients. Published by Elsevier B.V.

  20. New concept of the buildup factor in bent ducts

    International Nuclear Information System (INIS)

    Faik Ouahab, Z.; Jehouani, A.; Groetz, J.-E.

    2011-01-01

    A major problem confronting the radiation shielding designer is the accurate determination of neutron streaming through various penetrations in walls, ducts and mazes. The previous studies on neutron transmission were performed through empty ducts. The aim of this work is to evaluate the neutron transmission probability through a filled bent duct and the proposition of a new concept of the buildup factor for neutrons in multilegged ducts. An angular biaising technique is used in the Monte Carlo simulations to accelerate the calculation convergence. Results are first compared with those obtained by the MCNPX code. For an empty bent duct, the neutron transmission is only due to the neutron reflection on the duct wall. For a filled duct, the major contribution is due to the scattering on the atoms filling the duct.

  1. Molecular Mechanisms of Bile Duct Development

    OpenAIRE

    Zong, Yiwei; Stanger, Ben Z.

    2010-01-01

    The mammalian biliary system, consisting of the intrahepatic and extrahepatic bile ducts, is responsible for transporting bile from the liver to the intestine. Bile duct dysfunction, as is seen in some congenital biliary diseases such as Alagille syndrome and biliary atresia, can lead to the accumulation of bile in the liver, preventing the excretion of detoxification products and ultimately leading to liver damage. Bile duct formation requires coordinated cell-cell interactions, resulting in...

  2. Compact Buried Ducts in a Hot-Humid Climate House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, Dave [Home Innovation Research Labs, Upper Marlboro, MD (United States)

    2016-01-07

    "9A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely on encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences; 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs; 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.

  3. Unilateral Duplication Of Parotid Duct. A Rare Anatomical Variation

    Directory of Open Access Journals (Sweden)

    Humberto Ferreira Arquez

    2017-11-01

    Full Text Available Background: The paired parotid glands are the largest of the major salivary glands and produces mainly serous secretions. The secretion of this gland reaches the oral cavity through single parotid duct (Stensen’s duct. The parotid duct begins at the anterior border of the gland, crosses the masseter muscle, and then pierces the buccinator muscle to reach the mucosa lining the mouth at the level of the cheek. The purpose of this study is determine the morphologic features of the parotid duct and describe an anatomical variation until now unreported. Methods and Findings: A total of 17 cadavers were used for this study in the Morphology Laboratory at the University of Pamplona. In a cadaver were findings: The main parotid duct originated two conducts: Left superior parotid duct and Left inferior parotid duct, is observed the criss-cross of the ducts, and then perforated the buccinator muscle and entered the oral cavity at a double parotid papilla containing a double opening, separated from each other in 0,98 mm. In the remaining  33 parotid regions (97.06% the parotid duct is conformed to the classical descriptions given in anatomical textbooks. Conclusions: The parotid duct anatomy is important for duct endoscopy, lithotripsy, sialography and trans-ductal facial nerve stimulation in the early stage of facial palsy in some cases. The anatomical variations also has clinical importance for parotid gland surgery and facial cosmetic surgery. To keep in mind the parotid duct variation will reduce iatrogenic injury risks and improve diagnosis of parotid duct injury.

  4. Thoracic duct lymphography by subcutaneous contrast agent ...

    African Journals Online (AJOL)

    A second lymphography revealed a collateral thoracic duct that was not detected during the first lymphography. The collateral duct was ligated and chylothorax was resolved after the second surgery. The lymphography applied in this study was minimally-invasive and easily provided images of the thoracic duct in a dog with ...

  5. MRI of the labyrinth with volume rendering for cochlear implants candidates

    International Nuclear Information System (INIS)

    Sakata, Motomichi; Harada, Kuniaki; Shirase, Ryuji; Suzuki, Junpei; Nagahama, Hiroshi

    2009-01-01

    We demonstrated three-dimensional models of the labyrinth by volume rendering (VR) in preoperative assessment for cochlear implantation. MRI data sets were acquired in selected subjects using three-dimensional-fast spin echo sequences (3D-FSE). We produced the three-dimensional models of the labyrinth from axial heavily T2-weighted images. The three-dimensional models distinguished the scala tympani and scala vestibuli and provided multidirectional images. The optimal threshold three-dimensional models clearly showed the focal region of signal loss in the cochlear turns (47.1%) and the presence of inner ear anomalies (17.3%) in our series of patients. This study was concluded that these three-dimensional models by VR provide the oto-surgeon with precise, detailed, and easily interpreted information about the cochlear turns for cochlear implants candidates. (author)

  6. Selective deletion of cochlear hair cells causes rapid age-dependent changes in spiral ganglion and cochlear nucleus neurons.

    Science.gov (United States)

    Tong, Ling; Strong, Melissa K; Kaur, Tejbeer; Juiz, Jose M; Oesterle, Elizabeth C; Hume, Clifford; Warchol, Mark E; Palmiter, Richard D; Rubel, Edwin W

    2015-05-20

    During nervous system development, critical periods are usually defined as early periods during which manipulations dramatically change neuronal structure or function, whereas the same manipulations in mature animals have little or no effect on the same property. Neurons in the ventral cochlear nucleus (CN) are dependent on excitatory afferent input for survival during a critical period of development. Cochlear removal in young mammals and birds results in rapid death of target neurons in the CN. Cochlear removal in older animals results in little or no neuron death. However, the extent to which hair-cell-specific afferent activity prevents neuronal death in the neonatal brain is unknown. We further explore this phenomenon using a new mouse model that allows temporal control of cochlear hair cell deletion. Hair cells express the human diphtheria toxin (DT) receptor behind the Pou4f3 promoter. Injections of DT resulted in nearly complete loss of organ of Corti hair cells within 1 week of injection regardless of the age of injection. Injection of DT did not influence surrounding supporting cells directly in the sensory epithelium or spiral ganglion neurons (SGNs). Loss of hair cells in neonates resulted in rapid and profound neuronal loss in the ventral CN, but not when hair cells were eliminated at a more mature age. In addition, normal survival of SGNs was dependent on hair cell integrity early in development and less so in mature animals. This defines a previously undocumented critical period for SGN survival. Copyright © 2015 the authors 0270-6474/15/357878-14$15.00/0.

  7. Cystic Duct Closure by Sealing With Bipolar Electrocoagulation

    Science.gov (United States)

    Damgaard, B.; Jorgensen, L. N.; Larsen, S. S.; Kristiansen, V. B.

    2010-01-01

    Background: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure®) for closure of the cystic duct. Methods: The records from consecutive laparoscopic cholecystectomies performed in 2 hospitals with closure of the cystic duct with LigaSure after informed consent were recorded and complications and morbidity registered. The records were compared with those of patients undergoing laparoscopic cholecystectomy with closure of the cystic duct with clips during the same period. Results: During the study period, 218 laparoscopic cholecystectomies were performed; 102 of these were performed with the LigaSure. One patient was excluded due to violation of the protocol. We experienced no cases of cystic duct leakage, but in one patient, bile leakage from the gallbladder bed was observed probably due to a small aberrant duct. Conclusion: The LigaSure system was safe and effective for closure and division of the cystic duct in laparoscopic cholecystectomy. PMID:20412641

  8. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  9. Labyrinthectomy with cochlear implantation.

    Science.gov (United States)

    Zwolan, T A; Shepard, N T; Niparko, J K

    1993-05-01

    Numerous reports indicate that the cochlea remains responsive to electrical stimulation following labyrinthectomy. We report a case of a 47-year-old woman with a severe to profound sensorineural hearing loss from birth, who developed episodic vertigo with symptoms suggestive of delayed onset endolymphatic hydrops. Following 8 months of failed medical and vestibular rehabilitation management, a right-sided labyrinthectomy combined with cochlear implantation was performed without complication. Postoperatively the patient was free of vertigo. Attempts to activate the patient's device between 4 to 12 weeks after surgery were unsuccessful as stimulation of the electrodes resulted in discomfort. However, all 20 electrodes elicited comfortable hearing sensations 16 weeks postsurgery. One year after the successful activation, the patient demonstrated improved sound awareness and speech recognition with the implant when compared with preoperative performance with a hearing aid. This case study suggests that electrical detection thresholds with prosthetic stimulation may be unstable in the recently labyrinthectomized ear but supports and extends prior observations of preserved cochlear responsiveness after labyrinthectomy.

  10. Self-retaining small-looped catheter for narrow bile ducts in high common bile duct obstruction

    International Nuclear Information System (INIS)

    Guenther, R.W.; Daehnert, W.

    1985-01-01

    A new self-retaining catheter was devised for percutaneous drainage of small bile ducts. The device allows safe external drainage without the risk of catheter dislocation even in high bile duct obstruction. The catheter is also suitable for percutaneous nephrostomy in non-dilated pyelocaliceal system. (orig.)

  11. MR imaging of the cochlear modiolus after intratympanic administration of Gd-DTPA

    International Nuclear Information System (INIS)

    Kawai, Hisashi; Naganawa, Shinji; Ishihara, Shunichi; Sone, Michihiko; Nakashima, Tsutomu

    2010-01-01

    We evaluated whether enhancement of the cochlear modiolus could be visualized 24 hours after intratympanic injection of gadolinium diethylenetriamine penta-acetic acid (Gd-DTPA) using a 3-dimensional real inversion recovery sequence combined with a 32-channel head coil at 3 tesla. Intratympanic injection of Gd-DTPA has been reported for visualizing endolymphatic hydrops in Meniere's disease, and its use has shown communication between the cochlear perilymph and cerebrospinal fluid in the internal auditory canal. Although the cochlear modiolus has been considered the route for this communication, this has not been confirmed through direct visualization of its enhancement. We qualitatively and quantitatively evaluated the presence of contrast enhancement in the modiolus in 19 patients with clinically suspected endolymphatic hydrops or hearing loss who underwent imaging as described above. The contrast ratio (CR) between the cochlear modiolus and cerebellar white matter on the injected side was 1.09±1.23, and that on the non-injected side was -0.48±0.38 (P<0.01). In all subjects, the CR value was larger on the injected than non-injected side, and enhancement of the cochlear modiolus was also recognized visually. Intratympanic Gd-DTPA can be administered to visualize enhancement of the cochlear modiolus and may thereby reveal its functional anatomy. (author)

  12. Effects of a Word-Learning Training on Children With Cochlear Implants

    Science.gov (United States)

    Lund, Emily

    2014-01-01

    Preschool children with hearing loss who use cochlear implants demonstrate vocabulary delays when compared to their peers without hearing loss. These delays may be a result of deficient word-learning abilities; children with cochlear implants perform more poorly on rapid word-learning tasks than children with normal hearing. This study explored the malleability of rapid word learning of preschoolers with cochlear implants by evaluating the effects of a word-learning training on rapid word learning. A single-subject, multiple probe design across participants measured the impact of the training on children’s rapid word-learning performance. Participants included 5 preschool children with cochlear implants who had an expressive lexicon of less than 150 words. An investigator guided children to identify, repeat, and learn about unknown sets of words in 2-weekly sessions across 10 weeks. The probe measure, a rapid word-learning task with a different set of words than those taught during training, was collected in the baseline, training, and maintenance conditions. All participants improved their receptive rapid word-learning performance in the training condition. The functional relation indicates that the receptive rapid word-learning performance of children with cochlear implants is malleable. PMID:23981321

  13. Persistent Mullerian Duct Syndrome with Transverse Testicular ...

    African Journals Online (AJOL)

    Eastham JA, McEvoy K, Sullivan R, Chandrasoma P. A case of simultaneous bilateral nonseminomatous testicular tumors in persistent müllerian duct syndrome. J Urol 1992;148:407-8. 8. Shinmura Y, Yokoi T, Tsutsui Y. A case of clear cell adenocarcinoma of the müllerian duct in persistent müllerian duct syndrome: The first ...

  14. Cochlear implantation in the Mondini inner ear malformation.

    Science.gov (United States)

    Miyamoto, R T; Robbins, A J; Myres, W A; Pope, M L

    1986-07-01

    We report the case of a profoundly deaf 4-year-old boy with congenital deafness as a result of Mondini's dysplasia. The Mondini inner ear malformation is the result of arrested labyrinthine development during embryogenesis and is characterized by both bony and membranous anomalies of the inner ear. The dysplastic cochlear anatomy does not preclude successful cochlear implantation, and electrical threshold measurements are similar to those recorded in pediatric subjects deafened as a result of other causes.

  15. Spectral-Temporal Modulated Ripple Discrimination by Children With Cochlear Implants.

    Science.gov (United States)

    Landsberger, David M; Padilla, Monica; Martinez, Amy S; Eisenberg, Laurie S

    A postlingually implanted adult typically develops hearing with an intact auditory system, followed by periods of deafness (or near deafness) and adaptation to the implant. For an early implanted child whose brain is highly plastic, the auditory system matures with consistent input from a cochlear implant. It is likely that the auditory system of early implanted cochlear implant users is fundamentally different than postlingually implanted adults. The purpose of this study is to compare the basic psychophysical capabilities and limitations of these two populations on a spectral resolution task to determine potential effects of early deprivation and plasticity. Performance on a spectral resolution task (Spectral-temporally Modulated Ripple Test [SMRT]) was measured for 20 bilaterally implanted, prelingually deafened children (between 5 and 13 years of age) and 20 hearing children within the same age range. Additionally, 15 bilaterally implanted, postlingually deafened adults, and 10 hearing adults were tested on the same task. Cochlear implant users (adults and children) were tested bilaterally, and with each ear alone. Hearing listeners (adults and children) were tested with the unprocessed SMRT and with a vocoded version that simulates an 8-channel cochlear implant. For children with normal hearing, a positive correlation was found between age and SMRT score for both the unprocessed and vocoded versions. Older hearing children performed similarly to hearing adults in both the unprocessed and vocoded test conditions. However, for children with cochlear implants, no significant relationship was found between SMRT score and chronological age, age at implantation, or years of implant experience. Performance by children with cochlear implants was poorer than performance by cochlear implanted adults. It was also found that children implanted sequentially tended to have better scores with the first implant compared with the second implant. This difference was not

  16. Rehabilitation of deaf persons with cochlear implants

    International Nuclear Information System (INIS)

    Gstoettner, W.; Hamzavi, J.; Czerny, C.

    1997-01-01

    In the last decade, the rehabilitation of postlingually deaf adults and prelingually deaf children with cochlear implants has been established as a treatment of deafness. The technological development of the implant devices and improvement of the surgical technique have led to a considerable increase of hearing performance during the last years. The postlingually deaf adults are able to use the telephone and may be integrated in their original job. Prelingually deaf children can even visit normal schools after cochlear implantation and hearing rehabilitation training. In order to preoperatively establish the state of the cochlear, radiological diagnosis of the temporal bone is necessary. High resolution computerized tomography imaging of the temporal bone with coronar and axial 1 mm slices and MRI with thin slice technique (three dimensional, T2 weighted turbo-spinecho sequence with 0.7 mm slices) have proved to be valuable according to our experience. Furthermore a postoperative synoptical X-ray, in a modified Chausse III projection, offers good information about the position of the implant and insertion of the stimulating electrode into the cochlea. (orig.) [de

  17. Idiopathic chylopericardium treated by percutaneous thoracic duct embolization after failed surgical thoracic duct ligation

    Energy Technology Data Exchange (ETDEWEB)

    Courtney, Malachi; Ayyagari, Raj R. [Yale School of Medicine, Yale New Haven Hospital, New Haven, CT (United States); Division of Interventional Radiology, Department of Radiology, 789 Howard Avenue, P.O. Box 208042, New Haven, CT (United States)

    2015-06-15

    Chylopericardium rarely occurs in pediatric patients, but when it does it is most often a result of lymphatic injury during cardiothoracic surgery. Primary idiopathic chylopericardium is especially rare, with few cases in the pediatric literature. We report a 10-year-old boy who presented with primary idiopathic chylopericardium after unsuccessful initial treatment with surgical lymphatic ligation and creation of a pericardial window. Following readmission to the hospital for a right-side chylothorax resulting from the effluent from the pericardial window, he had successful treatment by interventional radiology with percutaneous thoracic duct embolization. This case illustrates the utility of thoracic duct embolization as a less-invasive alternative to surgical thoracic duct ligation, or as a salvage procedure when surgical ligation fails. (orig.)

  18. Idiopathic chylopericardium treated by percutaneous thoracic duct embolization after failed surgical thoracic duct ligation

    International Nuclear Information System (INIS)

    Courtney, Malachi; Ayyagari, Raj R.

    2015-01-01

    Chylopericardium rarely occurs in pediatric patients, but when it does it is most often a result of lymphatic injury during cardiothoracic surgery. Primary idiopathic chylopericardium is especially rare, with few cases in the pediatric literature. We report a 10-year-old boy who presented with primary idiopathic chylopericardium after unsuccessful initial treatment with surgical lymphatic ligation and creation of a pericardial window. Following readmission to the hospital for a right-side chylothorax resulting from the effluent from the pericardial window, he had successful treatment by interventional radiology with percutaneous thoracic duct embolization. This case illustrates the utility of thoracic duct embolization as a less-invasive alternative to surgical thoracic duct ligation, or as a salvage procedure when surgical ligation fails. (orig.)

  19. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome

    OpenAIRE

    Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya

    2016-01-01

    Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. F...

  20. Parotid Duct Repair with Intubation Tube: Technical Note

    Science.gov (United States)

    Öztürk, Muhammed Beşir; Barutca, Seda Asrufoğlu; Keskin, Elif Seda; Atik, Bekir

    2017-01-01

    The parotid duct can be damaged in traumatic injuries and surgical interventions. Early diagnosis and treatment of a duct injury is of great importance because complications such as sialocele and salivary gland fistula may develop if the duct is not surgically repaired. We think the cuff of an intubation tube is an ideal material in parotid duct repair, because of its technical characteristics, easiness of availability, and low-cost. In this paper, we described the use of the cuff cannula of an intubation tube for the diagnosis and treatment of parotid duct laceration, as a low-cost and easy to access material readily available in every operating room. PMID:28713751

  1. Dispersion properties of ducted whistlers, generated by lightning discharge

    Directory of Open Access Journals (Sweden)

    D. L. Pasmanik

    2005-06-01

    Full Text Available Whistler-mode wave propagation in magnetospheric ducts of enhanced cold plasma density is studied. The case of the arbitrary ratio of the duct radius to the whistler wavelength is considered, where the ray-tracing method is not applicable. The set of duct eigenmodes and their spatial structure are analysed and dependencies of eigenmode propagation properties on the duct characteristics are studied. Special attention is paid to the analysis of the group delay time of one-hop propagation of the whistler wave packet along the duct. We found that, in contrast to the case of a wide duct, the group delay time in a rather narrow duct decreases as the eigenmode number increases. The results obtained are suggested for an explanation of some types of multi-component whistler signals.

  2. The Phonemic Awareness Skills of Cochlear Implant Children and Children with Normal Hearing in Primary School

    Directory of Open Access Journals (Sweden)

    Aliakbar Dashtelei

    2015-12-01

    Full Text Available Objectives: Phonemic awareness skills have a significant impact on children speech and language. The purpose of this study was investigating the phonemic awareness skills of children with cochlear implant and normal hearing peers in primary school. Methods: phonemic awareness subscales of phonological awareness test were administered to 30 children with cochlear implantation at the first to sixth grades of primary school and 30 children with normal hearing who were matched in age with cochlear implant group. All of children were between 6 to 11 years old. Children with cochlear implant had at least 1 to 2 years of implant experience and they were over 5 years when they receive implantation. Children with cochlear implant were selected from Special education centers in Tehran and children with normal hearing were recruited from primary schools in Tehran. The phonemic awareness skills were assessed in both groups. Results: The results showed that the Mean scores of phonemic awareness skills in cochlear implant children were significantly lower than children with normal hearing (P<.0001. Discussion: children with cochlear implant, despite Cochlear implantation prosthesis, had lower performance in phonemic awareness when compared with normal hearing children. Therefore, due to importance of phonemic awareness skills in learning of literacy skills, and defects of these skills in children with cochlear implant, these skills should be assessed carefully in children with cochlear implant and rehabilitative interventions should be considered.

  3. Pre-, intra- and post-operative imaging of cochlear implants

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Naguib, N.N.N.; Burck, I. [University Hospital Frankfurt (Germany). Inst. of Diagnostic and Interventional Radiology; Tawfik, A. [Mansoura Univ. (Egypt). Dept. of Diagnostic and Interventional Radiology; Emam, A. [University Hospital Alexandria (Egypt). Dept. of Diagnostic and Interventional Radiology; Nour-Eldin, A. [University Hospital Cairo (Egypt). Dept. of Radiology; Stoever, T. [University Hospital of Frankfurt (Germany). Dept. of Otolaryngology

    2015-11-15

    The purpose of this review is to present essential imaging aspects in patients who are candidates for a possible cochlear implant as well as in postsurgical follow-up. Imaging plays a major role in providing information on preinterventional topography, variations and possible infections. Preoperative imaging using DVT, CT, MRI or CT and MRI together is essential for candidate selection, planning of surgical approach and exclusion of contraindications like the complete absence of the cochlea or cochlear nerve, or infection. Relative contraindications are variations of the cochlea and vestibulum. Intraoperative imaging can be performed by fluoroscopy, mobile radiography or DVT. Postoperative imaging is regularly performed by conventional X-ray, DVT, or CT. In summary, radiological imaging has its essential role in the pre- and post-interventional period for patients who are candidates for cochlear implants.

  4. Solitary intrahepatic bile-duct cyst presenting with Jaundice

    International Nuclear Information System (INIS)

    Park, Jeong Mi; Chun, Ki Sung; Ha, Hyun Kwon; Shinn, Kyung Sub; Bahk, Yong Whee; Kim, Jun Gi

    1989-01-01

    Caroli's disease is an uncommon condition, and characterized by congenital segmental saccular dilatation of intrahepatic bile ducts. A case of Caroli's disease, manifested by only a large communicating cystic dilatation of left intrahepatic bile duct and causing extrinsic pressure over the extrahepatic bile duct, is presented. The patient was 43-year-old housewife, hospitalized because of abdominal distension and severe jaundice. To relieve jaundice and alleviate surgical intervention, percutaneous drainage of the bile-duct cyst preceded surgery

  5. Is there a best side for cochlear implants in post-lingual patients?

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Damico, Thiago A; Gonçales, Alina S; Reis, Ana C M B; Isaac, Myriam de Lima; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2017-07-29

    Cochlear Implant is a sensory prosthesis capable of restoring hearing in patients with severe or profound bilateral sensorineural hearing loss. To evaluate if there is a better side to be implanted in post-lingual patients. Retrospective longitudinal study. Participants were 40 subjects, of both sex, mean age of 47 years, with post-lingual hearing loss, users of unilateral cochlear implant for more than 12 months and less than 24 months, with asymmetric auditor reserve between the ears (difference of 10dBNA, In at least one of the frequencies with a response, between the ears), divided into two groups. Group A was composed of individuals with cochlear implant in the ear with better auditory reserve and Group B with auditory reserve lower in relation to the contralateral side. There was no statistical difference for the tonal auditory threshold before and after cochlear implant. A better speech perception in pre-cochlear implant tests was present in B (20%), but the final results are similar in both groups. The cochlear implant in the ear with the worst auditory residue favors a bimodal hearing, which would allow the binaural summation, without compromising the improvement of the audiometric threshold and the speech perception. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  6. MRI ductography of contrast agent distribution and leakage in normal mouse mammary ducts and ducts with in situ cancer.

    Science.gov (United States)

    Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Conzen, Suzanne D; Karczmar, Gregory S

    2017-07-01

    High resolution 3D MRI was used to study contrast agent distribution and leakage in normal mouse mammary glands and glands containing in situ cancer after intra-ductal injection. Five female FVB/N mice (~19weeks old) with no detectable mammary cancer and eight C3(1) SV40 Tag virgin female mice (~15weeks old) with extensive in situ cancer were studied. A 34G, 45° tip Hamilton needle with a 25μL Hamilton syringe was inserted into the tip of the nipple and approximately 15μL of a Gadodiamide was injected slowly over 1min into the nipple and throughout the duct on one side of the inguinal gland. Following injection, the mouse was placed in a 9.4T MRI scanner, and a series of high resolution 3D T1-weighted images was acquired with a temporal resolution of 9.1min to follow contrast agent leakage from the ducts. The first image was acquired at about 12min after injection. Ductal enhancement regions detected in images acquired between 12 and 21min after contrast agent injection was five times smaller in SV40 mouse mammary ducts (pcontrast agent from the SV40 ducts. The contrast agent washout rate measured between 12min and 90min after injection was ~20% faster (p<0.004) in SV40 mammary ducts than in FVB/N mammary ducts. These results may be due to higher permeability of the SV40 ducts, likely due to the presence of in situ cancers. Therefore, increased permeability of ducts may indicate early stage breast cancers. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. STEREOLOGICAL ANALYSIS OF THE COCHLEAR NUCLEI OF MONKEY (MACACA FASCICULARIS AFTER DEAFFERENTATION

    Directory of Open Access Journals (Sweden)

    Ana M Insausti

    2011-05-01

    Full Text Available The cochlear nuclei (CN in the brainstem receive the input signals from the inner ear through the cochlear nerve, and transmit these signals to higher auditory centres. A variety of lesions of the cochlear nerve cause deafness. As reported in the literature, artificial removal of auditive input, or 'deafferentation', induces structural alterations in the CN. The purpose of this study was to estimate a number of relevant stereological parameters of the CN in control and deafferented Macaca fascicularis monkeys.

  8. Sequential bilateral cochlear implantation in children: parents' perspective and device use.

    NARCIS (Netherlands)

    Sparreboom, M.; Leeuw, A.R.; Snik, A.F.M.; Mylanus, E.A.M.

    2012-01-01

    OBJECTIVE: The purpose of this study was (1) to measure parental expectations before surgery of a sequentially placed second cochlear implant and compare these results with parental observations postoperatively and (2) to measure device use of the second cochlear implant and compare to unilateral

  9. Visualization of spiral ganglion neurites within the scala tympani with a cochlear implant in situ.

    Science.gov (United States)

    Chikar, Jennifer A; Batts, Shelley A; Pfingst, Bryan E; Raphael, Yehoash

    2009-05-15

    Current cochlear histology methods do not allow in situ processing of cochlear implants. The metal components of the implant preclude standard embedding and mid-modiolar sectioning, and whole mounts do not have the spatial resolution needed to view the implant within the scala tympani. One focus of recent auditory research is the regeneration of structures within the cochlea, particularly the ganglion cells and their processes, and there are multiple potential benefits to cochlear implant users from this work. To facilitate experimental investigations of auditory nerve regeneration performed in conjunction with cochlear implantation, it is critical to visualize the cochlear tissue and the implant together to determine if the nerve has made contact with the implant. This paper presents a novel histological technique that enables simultaneous visualization of the in situ cochlear implant and neurofilament-labeled nerve processes within the scala tympani, and the spatial relationship between them.

  10. A Case of Cochlear Implantation in Bromate-Induced Bilateral Sudden Deafness.

    Science.gov (United States)

    Eom, Tae-Ho; Lee, Sungsu; Cho, Hyong-Ho; Cho, Yong-Beom

    2015-04-01

    Despite the well-established nature of bromate-induced ototoxicity, cochlear implantation after bromate intoxication has been rarely documented. We hereby present a case of a 51-year-old female deafened completely after bromate ingestion. Her hearing was not restored by systemic steroid treatment and hearing aids were of no use. A cochlear implantation was performed on her right ear 3 months after the bromate ingestion. In bromate intoxication cases, early monitoring of hearing level is necessary and other drugs with potential ototoxicity should be avoided. The outcome of cochlear implantation was excellent in this case of bromate-induced deafness.

  11. Topics in Modeling of Cochlear Dynamics: Computation, Response and Stability Analysis

    Science.gov (United States)

    Filo, Maurice G.

    This thesis touches upon several topics in cochlear modeling. Throughout the literature, mathematical models of the cochlea vary according to the degree of biological realism to be incorporated. This thesis casts the cochlear model as a continuous space-time dynamical system using operator language. This framework encompasses a wider class of cochlear models and makes the dynamics more transparent and easier to analyze before applying any numerical method to discretize space. In fact, several numerical methods are investigated to study the computational efficiency of the finite dimensional realizations in space. Furthermore, we study the effects of the active gain perturbations on the stability of the linearized dynamics. The stability analysis is used to explain possible mechanisms underlying spontaneous otoacoustic emissions and tinnitus. Dynamic Mode Decomposition (DMD) is introduced as a useful tool to analyze the response of nonlinear cochlear models. Cochlear response features are illustrated using DMD which has the advantage of explicitly revealing the spatial modes of vibrations occurring in the Basilar Membrane (BM). Finally, we address the dynamic estimation problem of BM vibrations using Extended Kalman Filters (EKF). Due to the limitations of noninvasive sensing schemes, such algorithms are inevitable to estimate the dynamic behavior of a living cochlea.

  12. Evidence of across-channel processing for spectral-ripple discrimination in cochlear implant listeners.

    Science.gov (United States)

    Won, Jong Ho; Jones, Gary L; Drennan, Ward R; Jameyson, Elyse M; Rubinstein, Jay T

    2011-10-01

    Spectral-ripple discrimination has been used widely for psychoacoustical studies in normal-hearing, hearing-impaired, and cochlear implant listeners. The present study investigated the perceptual mechanism for spectral-ripple discrimination in cochlear implant listeners. The main goal of this study was to determine whether cochlear implant listeners use a local intensity cue or global spectral shape for spectral-ripple discrimination. The effect of electrode separation on spectral-ripple discrimination was also evaluated. Results showed that it is highly unlikely that cochlear implant listeners depend on a local intensity cue for spectral-ripple discrimination. A phenomenological model of spectral-ripple discrimination, as an "ideal observer," showed that a perceptual mechanism based on discrimination of a single intensity difference cannot account for performance of cochlear implant listeners. Spectral modulation depth and electrode separation were found to significantly affect spectral-ripple discrimination. The evidence supports the hypothesis that spectral-ripple discrimination involves integrating information from multiple channels. © 2011 Acoustical Society of America

  13. Effectiveness of duct sealing and duct insulation in multi-family buildings. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Karins, N.H.; Tuluca, A.; Modera, M.

    1997-07-01

    This research investigated the cost-effectiveness of sealing and insulating the accessible portions of duct systems exposed to unconditioned areas in multifamily housing. Airflow and temperature measurements were performed in 25 apartments served by 10 systems a 9 multi-family properties. The measurements were performed before and after each retrofit, and included apartment airflow (supply and return), duct system temperatures, system fan flow and duct leakage area. The costs for each retrofit were recorded. The data were analyzed and used to develop a prototypical multifamily house. This prototype was used in energy simulations (DOE-2.1E) and air infiltration simulations (COMIS 2.1). The simulations were performed for two climates: New York City and Albany. In each climate, one simulation was performed assuming the basement was tight, and another assuming the basement was leaky. Simulation results and average retrofit costs were used to calculate cost-effectiveness. The results of the analysis indicate that sealing leaks of the accessible ductwork is cost-effective under all conditions simulated (simple payback was between 3 and 4 years). Insulating the accessible ductwork, however, is only cost-effective for buildings with leaky basement, in both climates (simple paybacks were less than 5 years). The simple payback period for insulating the ducts in buildings with tight basements was greater than 10 years, the threshold of cost-effectiveness for this research. 13 refs., 5 figs., 27 tabs.

  14. ß-adrenergic regulation of ion transport in pancreatic ducts: Patch-clamp study of isolated rat pancreatic ducts

    DEFF Research Database (Denmark)

    Novak, I

    1998-01-01

    BACKGROUND & AIMS: In the intact pancreas, bicarbonate secretion is thought to be controlled by a number of regulators, including adrenergic agonists. The aim of this study was to investigate the effects of adrenergic agonists on pancreatic ducts, which are the site of bicarbonate secretion....... METHODS: Small intralobular ducts were isolated from rat pancreas and studied in vitro by the whole-cell patch clamp technique. Cell membrane voltages and currents were indicators of cellular ion transport. In some ducts, intracellular Ca2+ activity was measured by fluorescence optical methods. RESULTS...

  15. Noise suppression in duct

    International Nuclear Information System (INIS)

    Ahmed, A.; Barfeh, M.A.G.

    2001-01-01

    In air-conditioning system the noise generated by supply fan is carried by conditioned air through the ductwork. The noise created in ductwork run may be transmission, regenerative and ductborne. Transmission noise is fan noise, regenerative noise is due to turbulence in flow and ductborne noise is the noise radiating from duct to surroundings. Some noise is attenuated in ducts also but if noise level is high then it needs to be attenuated. A simple mitre bend can attenuate-noise. This principle is extended to V and M-shape ducts with inside lining of fibreglass, which gave maximum attenuation of 77 dB and 62 dB respectively corresponding to 8 kHz frequency as compared to mitre, bend giving maximum 18 dB attenuation. Sound level meter measured sound levels with octave band filter and tests were conducted in anechoic room. A V-shape attenuator can be used at fan outlet and high frequency noise can be minimized greatly. (author)

  16. Pressure analysis in ventilation ducts at bituminization facility

    International Nuclear Information System (INIS)

    Kikuchi, Naoki; Iimura, Masato; Takahashi, Yuki; Omori, Eiichi; Yamanouchi, Takamichi

    1997-09-01

    Pressure analysis in cell ventilation ducts at bituminization facility where the fire and explosion accident occured was carried out. This report also describes the results of bench mark calculations for computer code EVENT84 which was used for the accident analysis. The bench mark calculations were performed by comparing the analytical results by EVENT84 code with the experimental data of safety demonstration tests of ventilation system which were carried out by JAERI. We confirmed the applicability of EVENT84 code with the conservative results. The pressure analysis in cell ventilation ducts at bituminization facility were performed by comparing the analytical results of duct pressure by EVENT84 code with the yield stress of destroyed ducts by explosion, in order to estimate the scale of explosion. As a result, we could not explain the damage of ducts quantitatively, but we found the local pressure peaks analytically in downstream ducts where the serious damages were observed. (author)

  17. Protective role of hydrogen sulfide against noise-induced cochlear damage: a chronic intracochlear infusion model.

    Directory of Open Access Journals (Sweden)

    Xu Li

    Full Text Available BACKGROUND: A reduction in cochlear blood flow plays an essential role in noise-induced hearing loss (NIHL. The timely regulation of cochlear perfusion determines the progression and prognosis of NIHL. Hydrogen sulfide (H(2S has attracted increasing interest as a vasodilator in cardiovascular systems. This study identified the role of H(2S in cochlear blood flow regulation and noise protection. METHODOLOGY/PRINCIPAL FINDINGS: The gene and protein expression of the H(2S synthetase cystathionine-γ-lyase (CSE in the rat cochlea was examined using immunofluorescence and real-time PCR. Cochlear CSE mRNA levels varied according to the duration of noise exposure. A chronic intracochlear infusion model was built and artificial perilymph (AP, NaHS or DL-propargylglycine (PPG were locally administered. Local sodium hydrosulfide (NaHS significantly increased cochlear perfusion post-noise exposure. Cochlear morphological damage and hearing loss were alleviated in the NaHS group as measured by conventional auditory brainstem response (ABR, cochlear scanning electron microscope (SEM and outer hair cell (OHC count. The highest percentage of OHC loss occurred in the PPG group. CONCLUSIONS/SIGNIFICANCE: Our results suggest that H(2S plays an important role in the regulation of cochlear blood flow and the protection against noise. Further studies may identify a new preventive and therapeutic perspective on NIHL and other blood supply-related inner ear diseases.

  18. Cochlear pathology: CT and MRI findings

    International Nuclear Information System (INIS)

    Martinez, Manuel; Bruno, Claudio; Martin, Eduardo; Canale, Nancy; De Luca, Laura; Spina, Juan C. h

    2002-01-01

    The authors present a retrospective analysis of 50 patients with perceptive hearing loss. The neuro physiological work-up (evoked potentials, audiometric tests and otoemissions) identified the cochlea as the site of origin of the hearing loss. The imaging studies (high resolution CT and MR, including 3D volumes) showed petrous bone trauma (n=5) infections (bacterial or viral origin) (n=12) otosclerosis (n=8), Paget disease (n=3), and labyrinthine neurinomas (n=2). The other 20 cases showed development-linked disorders (Mitchel's, Mondini, Scheibe, Alexander, and hypoplasia of the cochlear canal). Imaging with CT and MR can identify in detail the structural abnormality affecting the cochlea and occasionally the immediate peri-cochlear region (otic capsule); the affected portion of the cochlea may thus be determined. (author)

  19. Outcomes and special considerations of cochlear implantation in waardenburg syndrome.

    Science.gov (United States)

    Kontorinis, Georgios; Lenarz, Thomas; Giourgas, Alexandros; Durisin, Martin; Lesinski-Schiedat, Anke

    2011-08-01

    The objective of this study was a state-of-the-art analysis of cochlear implantation in patients with Waardenburg syndrome (WS). Twenty-five patients with WS treated with cochlear implants in our department from 1990 to 2010. The 25 patients with WS underwent 35 cochlear implantations. Hearing outcome was evaluated using HSM sentence test in 65 dB in quiet, Freiburg Monosyllabic Test, and categories of auditory performance for children and compared with that of a control group. Anatomic abnormalities of the inner ear were examined using magnetic resonance imaging and computed tomography of the temporal bones. The mean follow-up time was 8.3 years (range, 0.3-18.3 yr). The majority achieved favorable postimplantation performance with mean HSM scores of 75.3% (range, 22.6%-99%) and Freiburg Monosyllabic Test scores of 67.8% (range, 14%-95%). However, in 4 cases, the results were less satisfactory. The comparison with the control group did not reveal any statistical significance (p = 0.56). In 6 patients (24%), behavioral disorders caused temporary difficulties during the rehabilitation procedure. Except of isolated large vestibule in 1 patient, the radiological assessment of the 50 temporal bones did not reveal any temporal bone abnormalities. Most patients with WS performed well with cochlear implants. However, WS is related to behavioral disorders that may cause temporary rehabilitation difficulties. Finally, temporal bone malformations that could affect cochlear implantation are notcharacteristic of WS.

  20. Duct Remediation Program: Engineered access research and construction

    International Nuclear Information System (INIS)

    Beckman, T.D.; Davis, M.M.; Karas, T.M.

    1992-01-01

    The Rocky Flats Plant, Duct Remediation mission concentrated on removing Plutonium Oxide from the process ductwork in the primary Plutonium processing facility. When possible, remediation took place from existing process gloveboxes. Fifteen locations were identified, however, that required accessing duct runs where no process gloveboxes existed. The building's second floor utility areas had many locations where long, inaccessible duct runs were prevalent. Consequently, an extensive program for design, procurement and construction was initiated to contain and isolate ducts for penetration when existing glovebox sites were not present

  1. Consistent approach to air-cleaning system duct design

    International Nuclear Information System (INIS)

    Miller, W.H.; Ornberg, S.C.; Rooney, K.L.

    1981-01-01

    Nuclear power plant air-cleaning system effectiveness is dependent on the capability of a duct system to safely convey contaminated gas to a filtration unit and subsequently to a point of discharge. This paper presents a logical and consistent design approach for selecting sheet metal ductwork construction to meet applicable criteria. The differences in design engineers' duct construction specifications are acknowledged. Typical duct construction details and suggestions for their effective use are presented. Improvements in duct design sections of ANSI/ASME N509-80 are highlighted. A detailed leakage analysis of a control room HVAC system is undertaken to illustrate the effects of conceptual design variations on duct construction requirements. Shortcomings of previously published analyses and interpretations of a current standard are included

  2. Reading skills after cochlear implantation

    NARCIS (Netherlands)

    Vermeulen, A.M.

    2007-01-01

    It has frequently been found that profoundly deaf children with conventional hearing aids have difficulties with the comprehension of written text. Cochlear Implants (CIs) were expected to enhance the reading comprehension of these profoundly deaf children because they provide auditory access to

  3. Learning and Memory Processes Following Cochlear Implantation:The Missing Piece of the Puzzle

    Directory of Open Access Journals (Sweden)

    David B. Pisoni

    2016-04-01

    Full Text Available At the present time, there is no question that cochlear implants work and often work very well in quiet listening conditions for many profoundly deaf children and adults. The speech and language outcomes data published over the last two decades document quite extensively the clinically significant benefits of cochlear implants. Although there now is a large body of evidence supporting the efficacy of cochlear implants as a medical intervention for profound hearing loss in both children and adults, there still remain a number of challenging unresolved clinical and theoretical issues that deal with the effectiveness of cochlear implants in individual patients that have not yet been successfully resolved. In this paper, we review recent findings on learning and memory, two central topics in the field of cognition that have been seriously neglected in research on cochlear implants. Our research findings on sequence learning, memory and organization processes, and retrieval strategies used in verbal learning and memory of categorized word lists suggests that basic domain-general learning abilities may be the missing piece of the puzzle in terms of understanding the cognitive factors that underlie the enormous individual differences and variability routinely observed in speech and language outcomes following cochlear implantation.

  4. Language understanding and vocabulary of early cochlear implanted children

    DEFF Research Database (Denmark)

    Percy-Smith, L; Busch, GW; Sandahl, M

    2013-01-01

    The aim of the study was to identify factors associated with the level of language understanding, the level of receptive and active vocabulary, and to estimate effect-related odds ratios for cochlear implanted children's language level.......The aim of the study was to identify factors associated with the level of language understanding, the level of receptive and active vocabulary, and to estimate effect-related odds ratios for cochlear implanted children's language level....

  5. Computational tool for postoperative evaluation of cochlear implant patients

    International Nuclear Information System (INIS)

    Giacomini, Guilherme; Pavan, Ana Luiza M.; Pina, Diana R. de; Altemani, Joao M.C.; Castilho, Arthur M.

    2016-01-01

    The aim of this study was to develop a tool to calculate the insertion depth angle of cochlear implants, from computed tomography exams. The tool uses different image processing techniques, such as thresholding and active contour. Then, we compared the average insertion depth angle of three different implant manufacturers. The developed tool can be used, in the future, to compare the insertion depth angle of the cochlear implant with postoperative response of patient's hearing. (author)

  6. Psycholinguistic abilities in cochlear implant and hearing impaired children

    OpenAIRE

    Hassan, Hatem Ezzeldin; Eldin, Sally Taher Kheir; Al Kasaby, Rasha Mohamed

    2014-01-01

    Background: Many congenitally sensorineural hearing loss (SNHL) children and cochlear implant (CI) recipients develop near-normal language skills. However, there is a wide variation in individual outcomes following cochlear implantation, or using hearing aids. Some CI recipients or Hearing aids users never develop useable speech and oral language skills. The causes of this enormous variation in outcomes are only partly understood at the present time. So, the aim of this study was to assess th...

  7. Quality of life and cochlear implantation in Usher syndrome type I.

    NARCIS (Netherlands)

    Damen, G.W.J.A.; Pennings, R.J.E.; Snik, A.F.M.; Mylanus, E.A.M.

    2006-01-01

    OBJECTIVES: The objectives of this descriptive, retrospective study were to evaluate quality of life, hearing, and vision in patients with Usher syndrome type I with and without cochlear implant. METHODS: Quality of life (QoL) of 14 patients with Usher type I (USH1) with a cochlear implant (CI)

  8. Parotid salivary duct stenosis following caudal maxillectomy.

    Science.gov (United States)

    Mestrinho, Lisa A; Faísca, Pedro B; Niza, Maria M R E

    2014-01-01

    Parotid salivary duct dilation was diagnosed in a 9-year-old male dog. The dog had undergone caudal maxillectomy on the ipsilateral side 2-years prior to presentation. Treatment consisted of parotid salivary duct excision and superficial parotidectomy that lead to the resolution of clinical signs. Transient facial neuropraxia was observed immediately after surgery and resolved spontaneously after 2-weeks. Parotid salivary duct dilation should be considered as a chronic postoperative complication following caudal maxillectomy.

  9. Magnetic resonance imaging of Muellerian duct anomalies in children

    International Nuclear Information System (INIS)

    Li, Yi; Phelps, Andrew; Zapala, Matthew A.; MacKenzie, John D.; MacKenzie, Tippi C.; Courtier, Jesse

    2016-01-01

    Muellerian duct anomalies encompass a wide variety of disorders resulting from abnormalities in the embryological development of the Muellerian ducts. In the prepubertal pediatric population, Muellerian duct anomalies are often incidental findings on studies obtained for other reasons. The onset of menses can prompt more clinical symptoms. Proper characterization of Muellerian duct anomalies is important because these anomalies can affect the development of gynecological disorders as well as fertility. Muellerian duct anomalies also carry a high association with other congenital anomalies, particularly renal abnormalities. MRI is widely considered the best modality for assessing Muellerian duct anomalies; it provides multiplanar capability, clear anatomical detail and tissue characterization without ionizing radiation. MRI allows for careful description of Muellerian duct anomalies, often leading to classification into the most widely accepted classification system for Muellerian duct anomalies. This system, developed by the American Society of Reproductive Medicine, includes seven subtypes: uterine agenesis/hypoplasia, unicornuate, didelphys, bicornuate, septate, arcuate, and diethylstilbestrol (DES) drug-related uterus. In cases of complex anomalies that defy classification, MRI allows detailed depiction of all components of the anatomical abnormality, allowing for proper management and surgical planning. (orig.)

  10. Staphylococcus lugdunensis: novel organism causing cochlear implant infection

    Directory of Open Access Journals (Sweden)

    Samina Bhumbra

    2014-06-01

    Full Text Available A majority of cochlear implant infections are caused by Staphylococcus aureus or Pseudomonas aeruginosa. Reported here is a pediatric patient with a cochlear implant infection caused by methicillin-resistant Staphylococcus lugdunensis, a coagulase-negative Staphylococcus that has only recently been determined to be clinically relevant (1988. Unlike other coagulase-negative Staphylococcus, it is more aggressive, carrying a greater potential for tissue destruction. In pediatrics, the organism is uncommon, poorly described, and generally pan-susceptible. Described herein is the presentation and management of this unusual organism in a pediatric setting.

  11. Water condensation promotes fungal growth in ventilation ducts

    Energy Technology Data Exchange (ETDEWEB)

    Pasanen, P.; Pasanen, A.-L. (University of Kupopio, Department of Environmental Sciences, Kuopio (Finland)); Jantunen, M. (National Public Health Institute, Kuopio (Finland))

    1993-01-01

    In a subarctic climate the diurnal variation in temperature may cause water condensation in ducts placed in the unheated spaces of a building. In this study, germination time and sporulation of a fungus, Penicillium verrucosum, were studied on dusty, galvanized steel sheet under different moisture conditions at room temperature. The effect of condensed water in a supply air duct on spore amplification was studied in an experimental ventilation set-up. In the field, air temperatures and the dew point temperature of air in the duct were monitored continuously for a week. P. verrucosum germinated on steel surfaces during five-hour incubation of the surface under humid conditions, when the surface has been moist for half an hour, germ tubes appeared within 17 hours. During 24-hour incubation under moist conditions, P. verrucosum produced hyphae and spores. In the experimental set-up the airborne spore counts increased when the air passed through a water-condensing section of the duct. Penicillium was the most abundant fungus sporulated on the moist duct surface. In the field, during humid weather, the surface temperature on the air stream surface decreased to the dew point temperature of the air in the duct. thus water condensation in air ducts may promote fungal growth. (au)

  12. The mental representation of living and nonliving things: differential weighting and interactivity of sensorial and non-sensorial features.

    Science.gov (United States)

    Ventura, Paulo; Morais, José; Brito-Mendes, Carlos; Kolinsky, Régine

    2005-02-01

    Warrington and colleagues (Warrington & McCarthy, 1983, 1987; Warrington & Shallice, 1984) claimed that sensorial and functional-associative (FA) features are differentially important in determining the meaning of living things (LT) and nonliving things (NLT). The first aim of the present study was to evaluate this hypothesis through two different access tasks: feature generation (Experiment 1) and cued recall (Experiment 2). The results of both experiments provided consistent empirical support for Warrington and colleagues' assumption. The second aim of the present study was to test a new differential interactivity hypothesis that combines Warrington and colleagueS' assumption with the notion of a higher number of intercorrelations and hence of a stronger connectivity between sensorial and non-sensorial features for LTs than for NLTs. This hypothesis was motivated by previoUs reports of an uncrossed interaction between domain (LTs vs NLTs) and attribute type (sensorial vs FA) in, for example, a feature verification task (Laws, Humber, Ramsey, & McCarthy, 1995): while FA attributes are verified faster than sensorial attributes for NLTs, no difference is observed for LTs. We replicated and generalised this finding using several feature verification tasks on both written words and pictures (Experiment 3), including in conditions aimed at minimising the intervention of priming biases and strategic or mnemonic processes (Experiment 4). The whole set of results suggests that both privileged relations between features and categories, and the differential importance of intercorrelations between features as a function of category, modulate access to semantic features.

  13. Risk factors for central bile duct injury complicating partial liver resection

    NARCIS (Netherlands)

    Boonstra, E. A.; de Boer, M. T.; Sieders, E.; Peeters, P. M. J. G.; de Jong, K. P.; Slooff, M. J. H.; Porte, R. J.

    Background: Bile duct injury is a serious complication following liver resection. Few studies have differentiated between leakage from small peripheral bile ducts and central bile duct injury (CBDI), defined as an injury leading to leakage or stenosis of the common bile duct, common hepatic duct,

  14. Optimum design of the injection duct system of a stenter machine

    Energy Technology Data Exchange (ETDEWEB)

    Juraeva, Makhsuda; Song, Dong Joo [Yeungnam University, Geyongsan (Korea, Republic of); Ryu, Kyung Jin [Ajou Motor College, Boryeong (Korea, Republic of)

    2017-05-15

    Stenter machines are used for drying fabrics in the textile industry and have a heater, injection duct system, and fans inside a chamber. The injection duct system has ducts and air-injecting holes. Plane-type injection duct systems were investigated to obtain uniform airflow at the air-injecting holes. The flow field of the injection duct systems was computed using ANSYS CFX with different heights of the duct end and different shapes for the air-injecting holes. There was a high mass flow rate at the air-injecting holes and high airflow circulation inside both plane-type and mountain-type ducts at the ends. The height of the duct end was varied between 40 mm and 160 mm. The injection duct systems were analyzed with four different shapes of air-injecting holes. The circular and elliptical holes had lower standard deviations of the mass flow rate than other shapes. Relatively uniform mass flow rates were obtained in the plane-type and mountain-type duct systems when the height of the duct end was 40 mm and the shape of the air-injecting holes was circular or elliptical. The developed injection duct systems were improved by obtaining a uniform mass flow rate at the air-injecting holes. A stenter prototype was fabricated with the developed injection duct system to confirm the numerical results. The developed injection duct system had better performance than the original system.

  15. Modeling and segmentation of intra-cochlear anatomy in conventional CT

    Science.gov (United States)

    Noble, Jack H.; Rutherford, Robert B.; Labadie, Robert F.; Majdani, Omid; Dawant, Benoit M.

    2010-03-01

    Cochlear implant surgery is a procedure performed to treat profound hearing loss. Since the cochlea is not visible in surgery, the physician uses anatomical landmarks to estimate the pose of the cochlea. Research has indicated that implanting the electrode in a particular cavity of the cochlea, the scala tympani, results in better hearing restoration. The success of the scala tympani implantation is largely dependent on the point of entry and angle of electrode insertion. Errors can occur due to the imprecise nature of landmark-based, manual navigation as well as inter-patient variations between scala tympani and the anatomical landmarks. In this work, we use point distribution models of the intra-cochlear anatomy to study the inter-patient variations between the cochlea and the typical anatomic landmarks, and we implement an active shape model technique to automatically localize intra-cochlear anatomy in conventional CT images, where intra-cochlear structures are not visible. This fully automatic segmentation could aid the surgeon to choose the point of entry and angle of approach to maximize the likelihood of scala tympani insertion, resulting in more substantial hearing restoration.

  16. Cochlear Damage Affects Neurotransmitter Chemistry in the Central Auditory System

    Directory of Open Access Journals (Sweden)

    Donald Albert Godfrey

    2014-11-01

    Full Text Available Tinnitus, the perception of a monotonous sound not actually present in the environment, affects nearly 20% of the population of the United States. Although there has been great progress in tinnitus research over the past 25 years, the neurochemical basis of tinnitus is still poorly understood. We review current research about the effects of various types of cochlear damage on the neurotransmitter chemistry in the central auditory system and document evidence that different changes in this chemistry can underlie similar behaviorally measured tinnitus symptoms. Most available data have been obtained from rodents following cochlear damage produced by cochlear ablation, loud sound, or ototoxic drugs. Effects on neurotransmitter systems have been measured as changes in neurotransmitter level, synthesis, release, uptake, and receptors. In this review, magnitudes of changes are presented for neurotransmitter-related amino acids, acetylcholine, and serotonin. A variety of effects have been found in these studies that may be related to animal model, survival time, type of cochlear damage, or methodology. The overall impression from the evidence presented is that any imbalance of neurotransmitter-related chemistry could disrupt auditory processing in such a way as to produce tinnitus.

  17. Interaction of tinnitus suppression and hearing ability after cochlear implantation.

    Science.gov (United States)

    Wang, Qian; Li, Jia-Nan; Lei, Guan-Xiong; Chen, Dai-Shi; Wang, Wei-Ze; Chen, Ai-Ting; Mong, Meng-Di; Li, Sun; Jiao, Qing-Shan; Yang, Shi-Ming

    2017-10-01

    To study the postoperative impact of cochlear implants (CIs) on tinnitus, as well as the impact of tinnitus on speech recognition with CI switched on. Fifty-two postlingual deafened CI recipients (21 males and 31 females) were assessed using an established Tinnitus Characteristics Questionnaire and Tinnitus Handicap Inventory (THI) before and after cochlear implantation. The tinnitus loudness was investigated when CI was switched on and off in CI recipients with persistent tinnitus. The relation between tinnitus loudness and recipients' satisfaction of cochlear implantation was analyzed by the visual analogue scale (VAS) score. With CI 'OFF', 42 CI recipients experienced tinnitus postimplant ipsilaterally and 44 contralaterally. Tinnitus was totally suppressed ipsilateral to the CI with CI 'ON' in 42.9%, partially suppressed in 42.9%, unchanged in 11.9% and aggravated in 2.4%. Tinnitus was totally suppressed contralaterally with CI 'ON' in 31.8% of CI recipients, partially suppressed in 47.7%, unchanged in 20.5%. Pearson correlation analysis showed that tinnitus loudness and the results of cochlear implant patients satisfaction was negatively correlated (r = .674, p tinnitus. The tinnitus loudness may affect patients' satisfaction with the use of CI.

  18. WAVE PROPAGATION in the HOT DUCT of VHTR

    Energy Technology Data Exchange (ETDEWEB)

    Richard Schultz; Jim C. P. Liou

    2013-07-01

    In VHTR, helium from the reactor vessel is conveyed to a power conversion unit through a hot duct. In a hypothesized Depressurized Conduction Cooldown event where a rupture of the hot duct occurs, pressure waves will be initiated and reverberate in the hot duct. A numerical model is developed to quantify the transients and the helium mass flux through the rupture for such events. The flow path of the helium forms a closed loop but only the hot duct is modeled in this study. The lower plum of the reactor vessel and the steam generator are treated as specified pressure and/or temperature boundary to the hot duct. The model is based on the conservation principles of mass, momentum and energy, and on the equations of state for helium. The numerical solution is based on the method of characteristics with specified time intervals with a predictor and corrector algorithm. The rupture sub-model gives reasonable results. Transients induced by ruptures with break area equaling 20%, 10%, and 5% of the duct cross-sectional area are described.

  19. Improving Access for Pediatric and Adult Cochlear Implant Candidates in Ontario

    Directory of Open Access Journals (Sweden)

    Yvonne Emily James

    2016-10-01

    Full Text Available In 2011, the Ontario Ministry of Health and Long-Term Care announced the one-time allocation of $5.9 million to be shared by cochlear implant programs at five Ontario hospitals. The primary goal of this reform was to address cochlear implant wait times. More specifically, this funding was aimed at reducing adult wait times by 50% and to completely eliminate pediatric waiting lists. Prior to this funding, wait times for pediatric and adult cochlear implants were known to exceed four years. The funding was provided in response to a growing body of research that demonstrates increased speech perception and vocabulary among pediatric recipients, and pressure from parents of children on cochlear implant waiting lists, surgeons and other involved healthcare providers (e.g., auditory verbal therapists, audiologists, and speech language pathologists. The decision to increase funding was also influenced by government stakeholders who believed this one-time investment would be returned as pediatric patients reach adulthood and are better equipped to participate in mainstream (i.e., hearing society. While this one-time funding model has the potential to eliminate wait times for pediatric patients, thereby ensuring these children can access therapeutic services as early as possible, it does not address the future of cochlear implant waiting lists or the capacity of health human resources to absorb this sudden and unprecedented influx of pediatric patients.

  20. A new computed tomography method to identify meningitis-related cochlear ossification and fibrosis before cochlear implantation.

    Science.gov (United States)

    Ichikawa, Kazunori; Kashio, Akinori; Mori, Harushi; Ochi, Atushi; Karino, Shotaro; Sakamoto, Takashi; Kakigi, Akinobu; Yamasoba, Tatsuya

    2014-04-01

    To develop a new method to determine the presence of intracochlear ossification and/or fibrosis in cochlear implantation candidates with bilateral profound deafness following meningitis. Diagnostic test assessment. A university hospital. This study involved 15 ears from 13 patients with profound deafness following meningitis who underwent cochlear implantation. These ears showed normal structures, soft tissue, partial bony occlusion, and complete bony occlusion in 4, 3, 2, and 6 ears, respectively. We measured radiodensity in Hounsfield units (HU) using 0.5-mm-thick axial high-resolution computed tomography image slices at 3 different levels in the basal turn, the fenestration, and inferior and ascending segment sites, located along the electrode-insertion path. Pixel-level analysis on the DICOM viewer yielded actual computed tomography values of intracochlear soft tissues by eliminating the partial volume effect. The values were compared with the intraoperative findings. Values for ossification (n = 12) ranged from +547 HU to +1137 HU; for fibrosis (n = 11), from +154 HU to +574 HU; and for fluid (n = 22), from -49 HU to +255 HU. From these values, we developed 2 presets of window width (WW) and window level (WL): (1) WW: 1800, WL: 1100 (200 HU to 2000 HU) and (2) WW: 1500, WL: 1250 (500 HU to 2000 HU). The results using these 2 presets corresponded well to the intraoperative findings. Our new method is easy and feasible for preoperative determination of the presence of cochlear ossification and/or fibrosis that develops following meningitis.

  1. Imaging manifestation of hepatocellular carcinoma with bile duct tumor thrombi

    International Nuclear Information System (INIS)

    Liu Qingyu; Chen Jianyu; Liang Biling; Hu Tao

    2008-01-01

    Objective: To analyze the imaging features of hepatocellular carcinoma(HCC) with bile duct tumor thrombi. Methods: Thirteen patients with bile duct tumor thrombi proved pathologically underwent imaging examination. MR and CT were performed in 3 cases, and 2 cases had CT only and 8 cases had MRI only. Ultrasonography(US) was performed in all 13 patients. The accuracy of bile duct tumor thrombi detection was compared between US, CT and MRI with Fisher test. Results: Liver tumors and bile duct tumor thrombi were demonstrated in all patients on CT or MRI. Presence of intraluminal soft tissue mass was found in four of five cases on CT, and mild enhancement of the intraluminal mass in the arterial phase was noted, dilated bile duct distal to tumor thrombi was detected in all five patients. Eleven Tumor thrombi showed slight low signal intensity on T 1 WI, slight high signal intensity on T 2 WI, and mild to moderate contrast enhancement on the contrast-enhanced MR images. The MRCP findings of tumor thrombi were as follows: interruption, stricture of the bile ducts or irregular filling defect in the bile ducts with dilated intrahepatic ducts, bile duet was abruptly interrupted or showed a 'rat-tail' stricture (n=5); the common bile duct was filled with tumor thrombi, intrahepatic bile duct dilatation and missing common bile duct was noted on MRCP (n=2). Bile duct tumor thrombi were correctly diagnosed in 7 cases on US, and 12 cases on CT or MRI. Six cases were misdiagnosed or miss-diagnosed on US, and 4 cases were misdiagnosed on CT or MRI. There was no significant difference between US and CT/MRI in diagnosis of bile duct tumor thrombi (P=0.270). Conclusion: CT or MR imaging is useful for the diagnosis of HCC with biliary tumor thrombi and for evaluating the extension of thrombi. (authors)

  2. Cochlear anatomy: CT and MR imaging

    International Nuclear Information System (INIS)

    Martinez, Manuel; Bruno, Claudio; Martin, Eduardo; Canale, Nancy; De Luca, Laura; Spina, Juan C. h

    2002-01-01

    The authors present a brief overview of the normal cochlear anatomy with CT and MR images in order to allow a more complete identification of the pathological findings in patients with perceptive hipoacusia. (author)

  3. Bile duct anastomotic stricture after pediatric living donor liver transplantation.

    Science.gov (United States)

    Chok, Kenneth S H; Chan, See Ching; Chan, Kwong Leung; Sharr, William W; Tam, Paul K H; Fan, Sheung Tat; Lo, Chung Mau

    2012-07-01

    Hepaticojejunostomy is a well-accepted method, whereas duct-to-duct anastomosis is gaining popularity for bile duct reconstruction in pediatric living donor liver transplantation (LDLT). Biliary complications, especially biliary anastomotic stricture (BAS), are not clearly defined. The aim of the present study is to determine the rate of BAS and its associated risk factors. The study included 78 pediatric patients (duct-to-duct anastomosis during LDLT. The median follow-up period for the BAS group and the non-BAS group was 57.8 and 79.5 months, respectively (P = .683). Ten of the patients with BAS required percutaneous transhepatic biliary drainage with or without dilatation for treating the stricture. Multivariable analysis showed that hepatic artery thrombosis and duct-to-duct anastomosis were 2 risk factors associated with BAS. In pediatric LDLT, hepaticojejunostomy is the preferred method for bile duct reconstruction, but more large-scale research needs to be done to reconfirm this result. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. A study on CT features of intrahepatic bile duct abscess

    International Nuclear Information System (INIS)

    Min Pengqiu; Li Peng; He Zhiyan; Chen Weixia; Liu Yan

    2001-01-01

    Objective: To evaluate CT features of intrahepatic bile duct abscess (IBDA) and its pathologic basis. Methods: The CT imaging data of 31 consecutive cases of intrahepatic bile duct abscess proved by surgery or clinical treatments from October 1989 to February 1999 were retrospectively studied. The causes included acute obstructive suppurative cholangitis and retrograde infection due to different etiologies. For all the cases, the CT manifestations of liver abscess, bile duct abnormalities, and their relationship were observed respectively. Results: Manifestations of liver abscess were revealed in all cases (31/31, 100%). The CT manifestations of bile duct abnormalities included signs of etiologies caused bile duct obstruction and other signs including cholangiectasis (29/31, 93.5%), the dilated bile ducts communicated with (5/31, 16.1%) or abut on (8/31, 25.8%) the abscesses, and gas collection in bile ducts (10/31, 32.2%). The signs showing the relationship between liver abscess and bile duct abnormalities were that the abscesses complied with the obstructive site and the dilated bile ducts (15/31, 48.4%), and the liver abscesses located in different (7/31, 22.6%) or same (4/31, 12.9%) liver lobes or segments with gas collection in the dilated bile ducts. Conclusion: The CT manifestations of IBDA included signs of liver abscess, abnormalities of bile ducts, and signs showing their relationship. CT scanning was helpful in making comprehensive and accurate diagnosis of IBDA

  5. Spelling in Written Stories by School-Age Children with Cochlear Implants

    Science.gov (United States)

    Straley, Sara G.; Werfel, Krystal L.; Hendricks, Alison Eisel

    2016-01-01

    This study evaluated the spelling of 3rd to 6th grade children with cochlear implants in written stories. Spelling was analysed using traditional correct/incorrect scoring as well as the Spelling Sensitivity Score, which provides linguistic information about spelling attempts. Children with cochlear implants spelled 86 per cent of words in stories…

  6. A Comparison of Simulation Capabilities for Ducts

    Energy Technology Data Exchange (ETDEWEB)

    Miller, William A [ORNL; Smith, Matt K [ORNL; Gu, Lixing [Florida Solar Energy Center (FSEC); New, Joshua Ryan [ORNL

    2014-11-01

    Typically, the cheapest way to install a central air conditioning system in residential buildings is to place the ductwork in the attic. Energy losses due to duct-attic interactions can be great, but current whole-house models are unable to capture the dynamic multi-mode physics of the interactions. The building industry is notoriously fragmented and unable to devote adequate research resources to solve this problem. Builders are going to continue to put ducts in the attic because floor space is too expensive to closet them within living space, and there are both construction and aesthetic issues with other approaches such as dropped ceilings. Thus, there is a substantial need to publicly document duct losses and the cost of energy used by ducts in attics so that practitioners, builders, homeowners and state and federal code officials can make informed decisions leading to changes in new construction and additional retrofit actions. Thus, the goal of this study is to conduct a comparison of AtticSim and EnergyPlus simulation algorithms to identify specific features for potential inclusion in EnergyPlus that would allow higher-fidelity modeling of HVAC operation and duct transport of conditioned air. It is anticipated that the resulting analysis from these simulation tools will inform energy decisions relating to the role of ducts in future building energy codes and standards.

  7. Parametric study of electromagnetic waves propagating in absorbing curved S ducts

    Science.gov (United States)

    Baumeister, Kenneth J.

    1989-01-01

    A finite-element Galerkin formulation has been developed to study attenuation of transverse magnetic (TM) waves propagating in two-dimensional S-curved ducts with absorbing walls. In the frequency range where the duct diameter and electromagnetic wave length are nearly equal, the effect of duct length, curvature (duct offset), and absorber wall thickness was examined. For a given offset in the curved duct, the length of the S-duct was found to significantly affect both the absorptive and reflective characteristics of the duct. For a straight and a curved duct with perfect electric conductor terminations, power attenuation contours were examined to determine electromagnetic wall properties associated with maximum input signal absorption. Offset of the S-duct was found to significantly affect the value of the wall permittivity associated with the optimal attenuation of the incident electromagnetic wave.

  8. Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)—Health Professional Version

    Science.gov (United States)

    Bile duct cancer (also called cholangiocarcinoma) can occur in the bile ducts in the liver (intrahepatic) or outside the liver (perihilar or distal extrahepatic). Learn about the types of bile duct cancer, risk factors, clinical features, staging, and treatment for bile duct cancer in this expert-reviewed summary.

  9. Expressive Language Development in 45 Cochlear Implanted Children Following 2 Years of Implantation

    Directory of Open Access Journals (Sweden)

    Seyed Basir Hashemi

    2011-10-01

    Full Text Available Objectives: Profound hearing loss encounters children with delay in speech and language. As it is known language acquisition in young deaf children is a lengthy process, but cochlear implanted children have better spoken language skills than if they had not received the device. According to the importance of cochlear implant in deaf child's language development, this study evaluates the effect of different variables on child's language performance. Methods: 45 cochlear implanted children were tested, all of whom had used the device for at least 2 years. In order to evaluate the children, the NEWSHA test which is fitted for Persian speaking children was performed and language development of the children was compared through stepwise discriminant analysis. Results: After evaluation of the effect of different variables like child's age of implantation, participating in rehabilitation classes, parent's cooperation and their level of education, we came to a conclusion that the child's age of implantation and rehabilitation program significantly develop the child's language performance. Discussion: The value of cochlear implant in improvement of deaf children in speech, language perception, production and comprehension is confirmed by different studies which have been done on cochlear implanted children. Also, the present study indicates that language development in cochlear implanted children is highly related to their age of implantation and rehabilitation program.

  10. A radiographic study of nasopalatine duct cysts

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Chan Duck; Hwang, Eui Hwan; Lee, Sang Rae [Dept. of Oral Radiology, College of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    1993-02-15

    The purpose of this study was to evaluate the clinical and radiographic features of 35 cases of nasopalatine duct cyst by means of the analysis of periapical and/or occlusal radiograms in 35 persons visited the Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University and Chonbuk National University. The obtained results were as follows: 1. The incidence of nasopalatine duct cysts was higher in males (74.3%) than in females (25.7%). 2. The nasopalatine duct cysts were the most frequently occurred in the 4th decades (34.3%). The 6th and 7th decades (17.1%, 17.1%) were next in order to frequency followed by the 5th decades (14.3%), the 3rd decades (8.6%), the 2nd decades (5.7%), and 8th decades (2.9%). 3. In the signs and symptoms of nasopalatine duct cysts, 25.7% were swelling, 17.1% were swelling and tenderness, 20.0% were swelling and pain, and 37.2% were a symptom. 4. In the shape of nasopalatine duct cysts, 40.0% were round type, 48.6% 11.8% were heart type. 5. In symmetry of the nasopalatine duct cysts, 11.4% were 6-10 mm, 48.6% were 11-20 mm, 25.7% were 21-30 mm, and 14.3% were 31-40 mm. 6. In the periphery of nasopalatine duct cysts, 82.9% were distinct, 17.1% were relatively distinct. 7. In the change of root, 51.5% were intact, 17.1% were root divergence, 20.0% were root resorption, and 11.4% were root divergence and resorption.

  11. A radiographic study of nasopalatine duct cysts

    International Nuclear Information System (INIS)

    Jun, Chan Duck; Hwang, Eui Hwan; Lee, Sang Rae

    1993-01-01

    The purpose of this study was to evaluate the clinical and radiographic features of 35 cases of nasopalatine duct cyst by means of the analysis of periapical and/or occlusal radiograms in 35 persons visited the Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University and Chonbuk National University. The obtained results were as follows: 1. The incidence of nasopalatine duct cysts was higher in males (74.3%) than in females (25.7%). 2. The nasopalatine duct cysts were the most frequently occurred in the 4th decades (34.3%). The 6th and 7th decades (17.1%, 17.1%) were next in order to frequency followed by the 5th decades (14.3%), the 3rd decades (8.6%), the 2nd decades (5.7%), and 8th decades (2.9%). 3. In the signs and symptoms of nasopalatine duct cysts, 25.7% were swelling, 17.1% were swelling and tenderness, 20.0% were swelling and pain, and 37.2% were a symptom. 4. In the shape of nasopalatine duct cysts, 40.0% were round type, 48.6% 11.8% were heart type. 5. In symmetry of the nasopalatine duct cysts, 11.4% were 6-10 mm, 48.6% were 11-20 mm, 25.7% were 21-30 mm, and 14.3% were 31-40 mm. 6. In the periphery of nasopalatine duct cysts, 82.9% were distinct, 17.1% were relatively distinct. 7. In the change of root, 51.5% were intact, 17.1% were root divergence, 20.0% were root resorption, and 11.4% were root divergence and resorption.

  12. Deriving cochlear delays in humans using otoacoustic emissions and auditory evoked potentials

    DEFF Research Database (Denmark)

    Pigasse, Gilles

    A great deal of the processing of incoming sounds to the auditory system occurs within the cochlear. The organ of Corti within the cochlea has differing mechanical properties along its length that broadly gives rise to frequency selectivity. Its stiffness is at maximum at the base and decreases...... relation between frequency and travel time in the cochlea defines the cochlear delay. This delay is directly associated with the signal analysis occurring in the inner ear and is therefore of primary interest to get a better knowledge of this organ. It is possible to estimate the cochlear delay by direct...... and invasive techniques, but these disrupt the normal functioning of the cochlea and are usually conducted in animals. In order to obtain an estimate of the cochlear delay that is closer to the normally functioning human cochlea, the present project investigates non-invasive methods in normal hearing adults...

  13. Speech Perception Outcomes after Cochlear Implantation in Children with GJB2/DFNB1 associated Deafness

    Directory of Open Access Journals (Sweden)

    Marina Davcheva-Chakar

    2014-03-01

    Full Text Available Background: Cochlear implants (CI for the rehabilitation of patients with profound or total bilateral sensorineural hypoacusis represent the initial use of electrical fields to provide audibility in cases where the use of sound amplifiers does not provide satisfactory results. Aims: To compare speech perception performance after cochlear implantation in children with connexin 26-associated deafness with that of a control group of children with deafness of unknown etiology. Study Design: Retrospective comparative study. Methods: During the period from 2006 to , cochlear implantation was performed on 26 children. Eighteen of these children had undergone genetic tests for mutation of the Gap Junction Protein Beta 2 (GJB2 gene. Bi-allelic GJB2 mutations were confirmed in 7 out of 18 examined children. In order to confirm whether genetic factors have influence on speech perception after cochlear implantation, we compared the post-implantation speech performance of seven children with mutations of the GBJ2 (connexin 26 gene with seven other children who had the wild type version of this particular gene. The latter were carefully matched according to the age at cochlear implantation. Speech perception performance was measured before cochlear implantation, and one and two years after implantation. All the patients were arranged in line with the appropriate speech perception category (SPC. Non-parametric tests, Friedman ANOVA and Mann-Whitney’s U test were used for statistical analysis. Results: Both groups showed similar improvements in speech perception scores after cochlear implantation. Statistical analysis did not confirm significant differences between the groups 12 and 24 months after cochlear implantation. Conclusion: The results obtained in this study showed an absence of apparent distinctions in the scores of speech perception between the two examined groups and therefore might have significant implications in selecting prognostic indicators

  14. Measure Guideline. Sealing and Insulating Ducts in Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Puttagunta, S. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2011-12-01

    This document begins with a discussion on potential cost and performance benefits of duct sealing and insulating. It continues with a review of typical duct materials and components and the overall procedures for assessing and improving the duct system.

  15. Immediate and delayed cochlear neuropathy after noise exposure in pubescent mice.

    Directory of Open Access Journals (Sweden)

    Jane Bjerg Jensen

    Full Text Available Moderate acoustic overexposure in adult rodents is known to cause acute loss of synapses on sensory inner hair cells (IHCs and delayed degeneration of the auditory nerve, despite the completely reversible temporary threshold shift (TTS and morphologically intact hair cells. Our objective was to determine whether a cochlear synaptopathy followed by neuropathy occurs after noise exposure in pubescence, and to define neuropathic versus non-neuropathic noise levels for pubescent mice. While exposing 6 week old CBA/CaJ mice to 8-16 kHz bandpass noise for 2 hrs, we defined 97 dB sound pressure level (SPL as the threshold for this particular type of neuropathic exposure associated with TTS, and 94 dB SPL as the highest non-neuropathic noise level associated with TTS. Exposure to 100 dB SPL caused permanent threshold shift although exposure of 16 week old mice to the same noise is reported to cause only TTS. Amplitude of wave I of the auditory brainstem response, which reflects the summed activity of the cochlear nerve, was complemented by synaptic ribbon counts in IHCs using confocal microscopy, and by stereological counts of peripheral axons and cell bodies of the cochlear nerve from 24 hours to 16 months post exposure. Mice exposed to neuropathic noise demonstrated immediate cochlear synaptopathy by 24 hours post exposure, and delayed neurodegeneration characterized by axonal retraction at 8 months, and spiral ganglion cell loss at 8-16 months post exposure. Although the damage was initially limited to the cochlear base, it progressed to also involve the cochlear apex by 8 months post exposure. Our data demonstrate a fine line between neuropathic and non-neuropathic noise levels associated with TTS in the pubescent cochlea.

  16. Evidence of across-channel processing for spectral-ripple discrimination in cochlear implant listeners a

    Science.gov (United States)

    Ho Won, Jong; Jones, Gary L.; Drennan, Ward R.; Jameyson, Elyse M.; Rubinstein, Jay T.

    2011-01-01

    Spectral-ripple discrimination has been used widely for psychoacoustical studies in normal-hearing, hearing-impaired, and cochlear implant listeners. The present study investigated the perceptual mechanism for spectral-ripple discrimination in cochlear implant listeners. The main goal of this study was to determine whether cochlear implant listeners use a local intensity cue or global spectral shape for spectral-ripple discrimination. The effect of electrode separation on spectral-ripple discrimination was also evaluated. Results showed that it is highly unlikely that cochlear implant listeners depend on a local intensity cue for spectral-ripple discrimination. A phenomenological model of spectral-ripple discrimination, as an “ideal observer,” showed that a perceptual mechanism based on discrimination of a single intensity difference cannot account for performance of cochlear implant listeners. Spectral modulation depth and electrode separation were found to significantly affect spectral-ripple discrimination. The evidence supports the hypothesis that spectral-ripple discrimination involves integrating information from multiple channels. PMID:21973363

  17. AUDITORY REHABILITATION AND BILATERAL COCHLEAR IMPLANT ON CHILD WHITH CEREBRAL PALSY

    Directory of Open Access Journals (Sweden)

    Anacléia Melo da Silva Hilgenberg

    2013-01-01

    Full Text Available OBJECTIVE: To describe the hearing and language improvement in children with cerebral palsy submitted to cochlear implantation bilaterally. METHODS: Prospective, analytical descriptive. Study case and a broad bibliographical analysis in MEDLINE/PUBMED and EMBASE including detailed analysis of the rehabilitation techniques as serial phonoaudiological appointments; Sessions of phonoterapy recorded and criterious analysis of the tests such as IT-MAIS and MacArthur analysis. The teste were applied after Bilateral Cochlear Implantation: 15, 20, 22, 31 e 38 months.RESULTS: The results obtained and bibliographical analysis showed that cochlear implantation in children with cerebral palsy and profound hearing loss is the best option at the moment to perform hearing rehabilitation. The IT-MAIS and MacArthur tests showed a big improvement at 15 and 38 months after use of the cochlear implants. The IT-MAIS test showed 40% score in the beggining and 75% at the end. Mac Arthur test revealed a big evolution at vocabulary comprehension (58 to 342 and linguistic repertory (54 to 289.

  18. A case of fascioliasis in common bile duct

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Soo Youn; Park, Cheol Min; Chung, Kyu Byung; Lee, Chang Hong; Park, Seung Chul; Choi, Sang Yong; Lim, Han Jong [Korea University College of Medicine, Seoul (Korea, Republic of)

    1989-10-15

    A case of Fascioliasis of common bile duct is confirmed by visualization of adult fluke. Fascioliasis caused by Fasciola hepatica, is common parasitic disease in cattle and sheep. Human is an accidental host. ERCP demonstrated irregular linear conglomerated filling defects in common bile duct. Through surgical intervention, we found adult flukes of F. hepatica and adenomatous hyperplasia of common bile duct.

  19. A case of fascioliasis in common bile duct

    International Nuclear Information System (INIS)

    Ham, Soo Youn; Park, Cheol Min; Chung, Kyu Byung; Lee, Chang Hong; Park, Seung Chul; Choi, Sang Yong; Lim, Han Jong

    1989-01-01

    A case of Fascioliasis of common bile duct is confirmed by visualization of adult fluke. Fascioliasis caused by Fasciola hepatica, is common parasitic disease in cattle and sheep. Human is an accidental host. ERCP demonstrated irregular linear conglomerated filling defects in common bile duct. Through surgical intervention, we found adult flukes of F. hepatica and adenomatous hyperplasia of common bile duct

  20. Treatment Options for Extrahepatic Bile Duct Cancer

    Science.gov (United States)

    ... Treatment Liver Cancer Prevention Liver Cancer Screening Research Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)–Patient Version Treatment ... are different types of treatment for patients with bile duct cancer. Different types of treatments are available ...

  1. Treatment Option Overview (Extrahepatic Bile Duct Cancer)

    Science.gov (United States)

    ... Treatment Liver Cancer Prevention Liver Cancer Screening Research Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)–Patient Version Treatment ... are different types of treatment for patients with bile duct cancer. Different types of treatments are available ...

  2. General Information about Extrahepatic Bile Duct Cancer

    Science.gov (United States)

    ... Treatment Liver Cancer Prevention Liver Cancer Screening Research Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)–Patient Version Treatment ... are different types of treatment for patients with bile duct cancer. Different types of treatments are available ...

  3. A Case of Adenomyomatous Hyperplasia of the Extrahepatic Bile Duct

    Directory of Open Access Journals (Sweden)

    Masakatsu Numata

    2011-08-01

    Full Text Available Adenomyomatous hyperplasia is rarely found in the extrahepatic bile duct. A 54-year-old man was referred to our center with a diagnosis of extrahepatic bile duct stenosis which had been detected by endoscopic retrograde choloangiopancreatography. Abdominal computed tomography revealed thickening of the wall of the middle extrahepatic bile duct, however no malignant cells were detected by cytology. Since bile duct carcinoma could not be ruled out, we performed resection of the extrahepatic duct accompanied by lymph node dissection. Histopathologically, the lesion was diagnosed as adenomyomatous hyperplasia of the extrahepatic bile duct. Present and previously reported cases showed the difficulty of making a diagnosis of adenomyomatous hyperplasia of the extrahepatic bile duct preoperatively or intraoperatively. Therefore, when adenomyomatous hyperplasia is suspected, a radical surgical procedure according to malignant disease may be necessary for definitive diagnosis.

  4. Ultrasound imaging of the mouse pancreatic duct using lipid microbubbles

    Science.gov (United States)

    Banerjee, B.; McKeown, K. R.; Skovan, B.; Ogram, E.; Ingram, P.; Ignatenko, N.; Paine-Murrieta, G.; Witte, R.; Matsunaga, T. O.

    2012-03-01

    Research requiring the murine pancreatic duct to be imaged is often challenging due to the difficulty in selectively cannulating the pancreatic duct. We have successfully catheterized the pancreatic duct through the common bile duct in severe combined immune deficient (SCID) mice and imaged the pancreatic duct with gas filled lipid microbubbles that increase ultrasound imaging sensitivity due to exquisite scattering at the gas/liquid interface. A SCID mouse was euthanized by CO2, a midline abdominal incision made, the common bile duct cut at its midpoint, a 2 cm, 32 gauge tip catheter was inserted about 1 mm into the duct and tied with suture. The duodenum and pancreas were excised, removed in toto, embedded in agar and an infusion pump was used to instill normal saline or lipid-coated microbubbles (10 million / ml) into the duct. B-mode images before and after infusion of the duct with microbubbles imaged the entire pancreatic duct (~ 1 cm) with high contrast. The microbubbles were cavitated by high mechanical index (HMI) ultrasound for imaging to be repeated. Our technique of catheterization and using lipid microbubbles as a contrast agent may provide an effective, affordable technique of imaging the murine pancreatic duct; cavitation with HMI ultrasound would enable repeated imaging to be performed and clustering of targeted microbubbles to receptors on ductal cells would allow pathology to be localized accurately. This research was supported by the Experimental Mouse Shared Service of the AZ Cancer Center (Grant Number P30CA023074, NIH/NCI and the GI SPORE (NIH/NCI P50 CA95060).

  5. Hepatocellular carcinoma with bile duct involvement : computed Tomographic (CT) findings

    International Nuclear Information System (INIS)

    Lee, Joon Woo; Han, Joon Koo; Kim, Tae Kyoung; And others

    2000-01-01

    To describe the radiologic features of computed tomography (CT) in hepatocellular carcinoma (HCC) with bile duct involvement. We retrospectively analyzed the two phase spiral CT findings of 31 patients in whom HCC with bile duct invasion (n=3D28) or compression (n=3D3), was diagnosed. Eight of these underwent follow up CT after transarterial chemoembolization. We analyzed the size, type, location, enhancement pattern, and lipiodol retention of parenchymal and intraductal masses, as well as their lymphadenopathy. In all patients with bile duct invasion, single or multiple masses were demonstrated in the bile ducts. Intraductal masses showed the same enhancement characteristics as the parenchymal mass (kappa 0.550, p less than 0.001), and were contiguous to this mass. In 14 of 28 patients, intraductal masses filled the peripheral intrahepatic bile ducts and extended to the common bile ducts. In the other 14, the parenchymal mass extended to the area of the porta hepatis and then directly invaded the large ducts. In nine of the 28 patients, there was a hypoattenuated cleft between the intraductal mass and ductal wall. In six, a parenchymal mass was not apparent (n=3D2), or was smaller than 2cm (n=3D4). In five of eight patients (62.5%), follow-up CT after transarterial chemoembolization showed compact or partial lipiodol retention within the intraductal mass. In patients with bile duct compression, perihilar lymph nodes were noted along with the dilated intrahepatic duct but no intra ductal mass was demonstrated in the duct. Hepatocellular carcinomas cause bile duct dilatation either by direct invasion or by extrinsic compression of the bile duct with surrounding enlarged nodes. For the diagnosis of this condition, CT is helpful. (author)

  6. Cyborgization: Deaf Education for Young Children in the Cochlear Implantation Era

    Science.gov (United States)

    Valente, Joseph Michael

    2011-01-01

    The author, who was raised oral deaf himself, recounts a visit to a school for young deaf children and discovers that young d/Deaf children and their rights are subverted by the cochlear implantation empire. The hypercapitalist, techno-manic times of cochlear implantation has wreaked havoc to the lives of not only young children with deafness but…

  7. The scala vestibuli for cochlear implantation. An anatomic study.

    Science.gov (United States)

    Gulya, A J; Steenerson, R L

    1996-02-01

    Traditionally, cochlear implantation has used the scala tympani (ST) for electrode insertion. When faced with ST ossification, the surgeon may elect to drill out the cochlea to accomplish partial electrode insertion. Theoretically, another option in this situation is to insert the electrode into the scala vestibuli (SV). To determine whether or not the dimensions of the SV are sufficient to accommodate an electrode array so as to assess the feasibility of SV cochlear implantation. The study of 20 normal human temporal bones, comparing the maximum diameter and surface area of the ST with those of the combined SV and scala media. The dimensions of the SV and scala media were comparable to those of the ST and appeared sufficient to accommodate a cochlear implant electrode array. It appears that the combination of SV and scala media is a viable alternative route for electrode insertion, at least on the basis of anatomic dimensions, in those cases in which the ST is obliterated.

  8. Self-made metal stent in treatment of nasolacrimal duct obstruction

    International Nuclear Information System (INIS)

    Du Wei; Pang Ruilin; Luo Gang; Gu Jingchuan; Gong Yongxiang

    2003-01-01

    Objective: To evaluate application of self-made metal stent in treatment of nasolacrimal duct obstruction. Methods: In total 15 cases, self-made metal stents made of stainless steel wire were implanted in 18 obstructed nasolacrimal ducts. The lacrimal passages were rinsed and re-canalized followed by antegrade inserting the guide wire from upper dacryon. A dilator was inserted over the guide wire, and then a stent was released from a sheath into the impaired section of nasolacrimal duct. Dacryocystography was performed before and after the interventional procedure. Results: Dacryocystography showed patent nasolacrimal duct after treatment. Epiphora disappeared completely in 11 cases (13 ducts), improved in 4 cases (5 ducts). These cases had been followed up for 61-219 days (167 days in average). Relapse was found in 2 cases (2 ducts) in three months. Those 2 stents were removed by surgical procedure and found occluded by granulation. Conclusion: Interventional placement of the self-made metal stent is a simple, safe, low-cost and effective treatment of the nasolacrimal duct obstruction

  9. Cystic duct remnant mucocele in a liver transplant recipient

    International Nuclear Information System (INIS)

    Ahlawat, Sushil K.; Fishbien, Thomas M.; Haddad, Nadim G.

    2008-01-01

    Cystic duct remnant mucocele is an extremely rare complication of liver transplantation in children. Surgical correction is usually required for cystic duct remnant mucocele when it causes biliary obstruction. We describe a 14-month-old liver transplant recipient who presented with biliary obstruction 1 month after orthotopic liver transplantation with an end-to-end choledochocholedocal biliary anastomosis for hepatoblastoma. US, CT and cholangiography findings were consistent with mucocele of the allograft cystic duct remnant. Surgery was not needed in our patient because the mucocele and biliary obstruction had resolved on repeat imaging most likely due to guidewire manipulation during cholangiography, resulting in opening of the cystic duct remnant orifice and drainage into the common duct. (orig.)

  10. Cystic duct remnant mucocele in a liver transplant recipient

    Energy Technology Data Exchange (ETDEWEB)

    Ahlawat, Sushil K. [Georgetown University Hospital, Department of Medicine, Division of Gastroenterology, Washington, DC (United States); University of Medicine and Dentistry of New Jersey, New Jersey Medical School, Newark, NJ (United States); Fishbien, Thomas M. [Georgetown University Hospital, Department of Medicine, Division of Gastroenterology, Washington, DC (United States); Haddad, Nadim G. [Georgetown University Hospital, Department of Surgery, Division of Transplant Surgery, Washington, DC (United States)

    2008-08-15

    Cystic duct remnant mucocele is an extremely rare complication of liver transplantation in children. Surgical correction is usually required for cystic duct remnant mucocele when it causes biliary obstruction. We describe a 14-month-old liver transplant recipient who presented with biliary obstruction 1 month after orthotopic liver transplantation with an end-to-end choledochocholedocal biliary anastomosis for hepatoblastoma. US, CT and cholangiography findings were consistent with mucocele of the allograft cystic duct remnant. Surgery was not needed in our patient because the mucocele and biliary obstruction had resolved on repeat imaging most likely due to guidewire manipulation during cholangiography, resulting in opening of the cystic duct remnant orifice and drainage into the common duct. (orig.)

  11. Effect of unilateral and simultaneous bilateral cochlear implantation on tinnitus : A Prospective Study

    NARCIS (Netherlands)

    van Zon, Alice; Smulders, Yvette E.; Ramakers, Geerte G. J.; Stegeman, Inge; Smit, Adriana L.; Van Zanten, Gijsbert A.; Stokroos, Robert J.; Hendrice, Nadia; Free, Rolien H.; Maat, Bert; Frijns, Johan H. M.; Mylanus, Emmanuel A. M.; Huinck, Wendy J.; Topsakal, Vedat; Tange, Rinze A.; Grolman, Wilko

    Objectives/HypothesisTo determine the effect of cochlear implantation on tinnitus perception in patients with severe bilateral postlingual sensorineural hearing loss and to demonstrate possible differences between unilateral and bilateral cochlear implantation. Study DesignProspective study.

  12. Bowing-reactivity trends in EBR-II assuming zero-swelling ducts

    International Nuclear Information System (INIS)

    Meneghetti, D.

    1994-01-01

    Predicted trends of duct-bowing reactivities for the Experimental Breeder Reactor II (EBR-II) are correlated with predicted row-wise duct deflections assuming use of idealized zero-void-swelling subassembly ducts. These assume no irradiation induced swellings of ducts but include estimates of the effects of irradiation-creep relaxation of thermally induced bowing stresses. The results illustrate the manners in which at-power creeps may affect subsequent duct deflections at zero power and thereby the trends of the bowing component of a subsequent power reactivity decrement

  13. [Bile duct lesions in laparoscopic cholecystectomy].

    Science.gov (United States)

    Siewert, J R; Ungeheuer, A; Feussner, H

    1994-09-01

    Laparoscopic cholecystectomy is both resulting in a slightly higher incidence of biliary lesions and a change of prevalence of the type of lesions. Damage to the biliary system occurs in 4 different types: The most severe case is the lesion with a structural defect of the hepatic or common bile duct with (IVa) or without (IVb) vascular injury. Tangential lesions without structural loss of the duct should be denominated as type III (IIIa with additional lesion to the vessels, type IIIb without). Type II comprehends late strictures without obvious intraoperative trauma to the duct. Type I includes immediate biliary fistulae of usually good prognosis. The increasing prevalence of structural defects of the bile ducts appears to be a peculiarity of laparoscopic cholecystectomy necessitating highly demanding operative repair. In the majority of cases, hepatico-jejunostomy or even intraparenchymatous anastomoses are required. Adaptation of well proven principles of open surgery is the best prevention of biliary lesions in laparoscopic cholecystectomy as well as the readiness to convert early to the open procedure.

  14. Depressurization test on hot gas duct

    International Nuclear Information System (INIS)

    Tanihira, Masanori; Kunitomi; Kazuhiko; Inagaki, Yoshiyuki; Miyamoto, Yoshiaki; Sato, Yutaka.

    1989-05-01

    To study the integrity of internal structures and the characteristics in a hot gas duct under the rapid depressurization accident, depressurization tests have been carried out using a test apparatus installed the hot gas duct with the same size and the same structures as that of the High Temperature Engineering Test Reactor (HTTR). The tests have been performed with three parameters: depressurization rate (0.14-3.08 MPa/s) determined by orifice diameter, area of the open space at the slide joint (11.9-2036 mm 2 ), and initial pressure (1.0-4.0 MPa) filled up in a pressure vessel, by using nitrogen gas and helium gas. The maximum pressure difference applied on the internal structures of the hot gas duct was 2.69 MPa on the liner tube and 0.45 MPa on the separating plate. After all tests were completed, the hot gas duct which was used in the tests was disassembled. Inspection revealed that there were no failure and no deformation on the internal structures such as separating plates, insulation layers, a liner tube and a pressure tube. (author)

  15. Ultrasound appearance of chronic mammary duct ectasia

    Energy Technology Data Exchange (ETDEWEB)

    Duchesne, N. [Ottawa Hospital, Dept. of Radiology, Ottawa, Ontario (Canada)]. E-mail: nathalie_duchesne_22@yahoo.ca; Skolnik, S. [Univ. of Toronto, Dept. of Family Medicine, Toronto, Ontario (Canada); Bilmer, S. [Ottawa Hospital, Dept. of Radiology, Ottawa, Ontario (Canada)

    2005-12-15

    Mammary duct ectasia (MDE), also called periductal mastitis, mammary dysplasia, or plasma cell mastitis, is a benign condition of the mammary gland first described by Haagensen in 1951. The etiology of MDE is unknown and its pathogenesis still controversial; the periductal inflammation could be either the cause or the result of dilated damaged ducts. The process is usually bilateral and asymptomatic, with only a small percentage of patients presenting with symptoms that may include long course of tumour formation, usually subareolar breast lumps, nipple discharge, nipple retraction, mastalgia, and mammary abscess or fistulas. Mammographic presentation of MDE is well known; its features include periductal calcification, benign intraductal calcification, and retroareolar duct dilatation. The periductal calcification results from dystrophic calcification and forms calcified rings or very dense, oval, elongated calcifications, each with a central lucency representing the dilated duct. Intraductal calcifications of duct ectasia represent inspissated intraductal material and are typically of uniform high density, often needle-like, and occasionally branching. Occasionally, there are no mammographic findings, and the diagnosis must rely on sonographic features. Appearance of MDE on ultrasonography (US) depends on the stage of the disease and the contents of the dilated ducts. The acute presentation has been demonstrated in the literature more often than has its chronic counterpart. In the former, duct content can vary from anechoic to isoechoic with surrounding fatty tissue. In chronic MDE, episodes of inflammation are longer. This tends to result in secretions that have a more solid, cheesy texture, partly due to cholesterol crystals, foam cells, and inflammatory cells. For both types of MDE, the appearance can mimic high-grade ductal carcinoma in situ (DCIS) on US. In this essay, 2 chronic MDE cases are presented and their US appearance discussed. Our goal is to explore

  16. Ultrasound appearance of chronic mammary duct ectasia

    International Nuclear Information System (INIS)

    Duchesne, N.; Skolnik, S.; Bilmer, S.

    2005-01-01

    Mammary duct ectasia (MDE), also called periductal mastitis, mammary dysplasia, or plasma cell mastitis, is a benign condition of the mammary gland first described by Haagensen in 1951. The etiology of MDE is unknown and its pathogenesis still controversial; the periductal inflammation could be either the cause or the result of dilated damaged ducts. The process is usually bilateral and asymptomatic, with only a small percentage of patients presenting with symptoms that may include long course of tumour formation, usually subareolar breast lumps, nipple discharge, nipple retraction, mastalgia, and mammary abscess or fistulas. Mammographic presentation of MDE is well known; its features include periductal calcification, benign intraductal calcification, and retroareolar duct dilatation. The periductal calcification results from dystrophic calcification and forms calcified rings or very dense, oval, elongated calcifications, each with a central lucency representing the dilated duct. Intraductal calcifications of duct ectasia represent inspissated intraductal material and are typically of uniform high density, often needle-like, and occasionally branching. Occasionally, there are no mammographic findings, and the diagnosis must rely on sonographic features. Appearance of MDE on ultrasonography (US) depends on the stage of the disease and the contents of the dilated ducts. The acute presentation has been demonstrated in the literature more often than has its chronic counterpart. In the former, duct content can vary from anechoic to isoechoic with surrounding fatty tissue. In chronic MDE, episodes of inflammation are longer. This tends to result in secretions that have a more solid, cheesy texture, partly due to cholesterol crystals, foam cells, and inflammatory cells. For both types of MDE, the appearance can mimic high-grade ductal carcinoma in situ (DCIS) on US. In this essay, 2 chronic MDE cases are presented and their US appearance discussed. Our goal is to explore

  17. HVAC; Heating, Ventilation, Air Conditioning - Aerosol Duct Sealant

    Science.gov (United States)

    2016-09-01

    material was applied. Annual energy and cost savings were predicted based on a typical weather year for each site. The installation of the duct...Balance reports; Visible dust streaks on duct work, ceilings near supply diffusers, or electrical boxes; Comfort complaints Specific Leakage...energy consumption , depending on the HVAC system type and the location of the ducts that were sealed. The cost effectiveness of the technology is

  18. Free-form image registration of human cochlear μCT data using skeleton similarity as anatomical prior

    DEFF Research Database (Denmark)

    Kjer, Hans Martin; Fagertun, Jens; Vera, Sergio

    2016-01-01

    Better understanding of the anatomical variability of the human cochlear is important for the design and function of Cochlear Implants. Proper non-rigid alignment of high-resolution cochlear μCT data is a challenge for the typical cubic B-spline registration model. In this paper we study one way ...

  19. Cochlear Implantation and Single-sided Deafness: A Systematic Review of the Literature

    Directory of Open Access Journals (Sweden)

    Cabral Junior, Francisco

    2015-07-01

    Full Text Available Introduction Current data show that binaural hearing is superior to unilateral hearing, specifically in the understanding of speech in noisy environments. Furthermore, unilateral hearing reduce onés ability to localize sound. Objectives This study provides a systematic review of recent studies to evaluate the outcomes of cochlear implantation in patients with single-sided deafness (SSD with regards to speech discrimination, sound localization and tinnitus suppression. Data Synthesis We performed a search in the PubMed, Cochrane Library and Lilacs databases to assess studies related to cochlear implantation in patients with unilateral deafness. After critical appraisal, eleven studies were selected for data extraction and analysis of demographic, study design and outcome data. Conclusion Although some studies have shown encouraging results on cochlear implantation and SSD, all fail to provide a high level of evidence. Larger studies are necessary to define the tangible benefits of cochlear implantation in patients with SSD.

  20. A phone-assistive device based on Bluetooth technology for cochlear implant users.

    Science.gov (United States)

    Qian, Haifeng; Loizou, Philipos C; Dorman, Michael F

    2003-09-01

    Hearing-impaired people, and particularly hearing-aid and cochlear-implant users, often have difficulty communicating over the telephone. The intelligibility of telephone speech is considerably lower than the intelligibility of face-to-face speech. This is partly because of lack of visual cues, limited telephone bandwidth, and background noise. In addition, cellphones may cause interference with the hearing aid or cochlear implant. To address these problems that hearing-impaired people experience with telephones, this paper proposes a wireless phone adapter that can be used to route the audio signal directly to the hearing aid or cochlear implant processor. This adapter is based on Bluetooth technology. The favorable features of this new wireless technology make the adapter superior to traditional assistive listening devices. A hardware prototype was built and software programs were written to implement the headset profile in the Bluetooth specification. Three cochlear implant users were tested with the proposed phone-adapter and reported good speech quality.

  1. Long latency auditory evoked potentials in children with cochlear implants: systematic review.

    Science.gov (United States)

    Silva, Liliane Aparecida Fagundes; Couto, Maria Inês Vieira; Matas, Carla Gentile; Carvalho, Ana Claudia Martinho de

    2013-11-25

    The aim of this study was to analyze the findings on Cortical Auditory Evoked Potentials in children with cochlear implant through a systematic literature review. After formulation of research question and search of studies in four data bases with the following descriptors: electrophysiology (eletrofisiologia), cochlear implantation (implante coclear), child (criança), neuronal plasticity (plasticidade neuronal) and audiology (audiologia), were selected articles (original and complete) published between 2002 and 2013 in Brazilian Portuguese or English. A total of 208 studies were found; however, only 13 contemplated the established criteria and were further analyzed; was made data extraction for analysis of methodology and content of the studies. The results described suggest rapid changes in P1 component of Cortical Auditory Evoked Potentials in children with cochlear implants. Although there are few studies on the theme, cochlear implant has been shown to produce effective changes in central auditory path ways especially in children implanted before 3 years and 6 months of age.

  2. Intracochlear pressure measurements in scala media inform models of cochlear mechanics

    Science.gov (United States)

    Kale, Sushrut; Olson, Elizabeth S.

    2015-12-01

    In the classic view of cochlear mechanics, the cochlea is comprised of two identical fluid chambers separated by the cochlear partition (CP). In this view the traveling wave pressures in the two chambers mirror each other; they are equal in magnitude and opposite in phase. A fast pressure mode adds approximately uniformly. More recent models of cochlear mechanics take into account the structural complexity of the CP and the resulting additional mechanical modes would lead to distinct (non-symmetric) patterns of pressure and motion on the two sides of the CP. However, there was little to no physiological data that explored these predictions. To this aim, we measured intracochlear fluid pressure in scala media (SM), including measurements close to the sensory tissue, using miniaturized pressure sensors (˜ 80 μm outer diameter). Measurements were made in-vivo from the basal cochlear turn in gerbils. SM pressure was measured at two longitudinal locations in different preparations. In a subset of the experiments SM and ST (scala tympani) pressures were measured at the same longitudinal location. Traveling wave pressures were observed in both SM and ST, and showed the relative phase predicted by the classical theory. In addition, SM pressure showed spatial variations that had not been observed in ST, which points to a relatively complex CP motion on the SM side. These data both underscore the first-order validity of the classic cochlear traveling wave model, and open a new view to CP mechanics.

  3. High-Performance Ducts in Hot-Dry Climates

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, Marc [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Chitwood, Rick [National Renewable Energy Laboratory (NREL), Golden, CO (United States); German, Alea [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Weitzel, Elizabeth [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-07-30

    Duct thermal losses and air leakage have long been recognized as prime culprits in the degradation of heating, ventilating, and air-conditioning (HVAC) system efficiency. Both the U.S. Department of Energy’s Zero Energy Ready Home program and California’s proposed 2016 Title 24 Residential Energy Efficiency Standards require that ducts be installed within conditioned space or that other measures be taken to provide similar improvements in delivery effectiveness (DE). Pacific Gas & Electric Company commissioned a study to evaluate ducts in conditioned space and high-performance attics (HPAs) in support of the proposed codes and standards enhancements included in California’s 2016 Title 24 Residential Energy Efficiency Standards. The goal was to work with a select group of builders to design and install high-performance duct (HPD) systems, such as ducts in conditioned space (DCS), in one or more of their homes and to obtain test data to verify the improvement in DE compared to standard practice. Davis Energy Group (DEG) helped select the builders and led a team that provided information about HPD strategies to them. DEG also observed the construction process, completed testing, and collected cost data.

  4. Characterization of flow in a scroll duct

    Science.gov (United States)

    Begg, E. K.; Bennett, J. C.

    1985-01-01

    A quantitative, flow visualization study was made of a partially elliptic cross section, inward curving duct (scroll duct), with an axial outflow through a vaneless annular cutlet. The working fluid was water, with a Re(d) of 40,000 at the inlet to the scroll duct, this Reynolds number being representative of the conditions in an actual gas turbine scroll. Both still and high speed moving pictures of fluorescein dye injected into the flow and illuminated by an argon ion laser were used to document the flow. Strong secondary flow, similar to the secondary flow in a pipe bend, was found in the bottom half of the scroll within the first 180 degs of turning. The pressure field set up by the turning duct was strong enough to affect the inlet flow condition. At 90 degs downstream, the large scale secondary flow was found to be oscillatory in nature. The exit flow was nonuniform in the annular exit. By 270 degs downstream, the flow appeared unorganized with no distinctive secondary flow pattern. Large scale structures from the upstream core region appeared by 90 degs and continued through the duct to reenter at the inlet section.

  5. Assessment of morphological-functional state of children with cochlear implants

    Directory of Open Access Journals (Sweden)

    V.M. Pysanko

    2016-10-01

    Full Text Available Purpose: assessment of morphological-functional state of pre-school age children with cochlear implants and substantiation of need in post-operative rehabilitation in period of preparation for comprehensive school. Material: we tested weakly hearing children with cochlear implants (n=127, age - 5.6±0.6 years. They were the main group. Control group consisted of children with normal hearing (n=70, age - 5.7±0.4 years. Morphological-functional state was assessed by indicators of physical and biological condition, visual analyzer, posture parameters and foot arch, muscular system and level of coordination. We calculated index of integral morphological-functional state assessment. Results: Morphological functional state of most of children (with cochlear implants was characterized by low physical condition indicators and disharmony. We observed delay in biological development. Index of morphological-functional state integral assessment witnesses, that such child can not study in comprehensive school. Rehabilitation program can reduce the gap between children with normal hearing and those with cochlear implants. Conclusions: Rehabilitation program facilitates quicker domestic and social rehabilitation of children at the account of widening the circle of communication, learning new actions and conceptions. It can permit for such children to study at school together with their healthy peers.

  6. Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation.

    Science.gov (United States)

    Mangado, Nerea; Ceresa, Mario; Duchateau, Nicolas; Kjer, Hans Martin; Vera, Sergio; Dejea Velardo, Hector; Mistrik, Pavel; Paulsen, Rasmus R; Fagertun, Jens; Noailly, Jérôme; Piella, Gemma; González Ballester, Miguel Ángel

    2016-08-01

    Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, we propose an automatic framework for the generation of patient-specific meshes for finite element modeling of the implanted cochlea. First, a statistical shape model is constructed from high-resolution anatomical μCT images. Then, by fitting the statistical model to a patient's CT image, an accurate model of the patient-specific cochlea anatomy is obtained. An algorithm based on the parallel transport frame is employed to perform the virtual insertion of the cochlear implant. Our automatic framework also incorporates the surrounding bone and nerve fibers and assigns constitutive parameters to all components of the finite element model. This model can then be used to study in silico the effects of the electrical stimulation of the cochlear implant. Results are shown on a total of 25 models of patients. In all cases, a final mesh suitable for finite element simulations was obtained, in an average time of 94 s. The framework has proven to be fast and robust, and is promising for a detailed prognosis of the cochlear implantation surgery.

  7. A non-local computational boundary condition for duct acoustics

    Science.gov (United States)

    Zorumski, William E.; Watson, Willie R.; Hodge, Steve L.

    1994-01-01

    A non-local boundary condition is formulated for acoustic waves in ducts without flow. The ducts are two dimensional with constant area, but with variable impedance wall lining. Extension of the formulation to three dimensional and variable area ducts is straightforward in principle, but requires significantly more computation. The boundary condition simulates a nonreflecting wave field in an infinite duct. It is implemented by a constant matrix operator which is applied at the boundary of the computational domain. An efficient computational solution scheme is developed which allows calculations for high frequencies and long duct lengths. This computational solution utilizes the boundary condition to limit the computational space while preserving the radiation boundary condition. The boundary condition is tested for several sources. It is demonstrated that the boundary condition can be applied close to the sound sources, rendering the computational domain small. Computational solutions with the new non-local boundary condition are shown to be consistent with the known solutions for nonreflecting wavefields in an infinite uniform duct.

  8. On Computations of Duct Acoustics with Near Cut-Off Frequency

    Science.gov (United States)

    Dong, Thomas Z.; Povinelli, Louis A.

    1997-01-01

    The cut-off is a unique feature associated with duct acoustics due to the presence of duct walls. A study of this cut-off effect on the computations of duct acoustics is performed in the present work. The results show that the computation of duct acoustic modes near cut-off requires higher numerical resolutions than others to avoid being numerically cut off. Duct acoustic problems in Category 2 are solved by the DRP finite difference scheme with the selective artificial damping method and results are presented and compared to reference solutions.

  9. Clinical outcomes of scala vestibuli cochlear implantation in children with partial labyrinthine ossification.

    Science.gov (United States)

    Lin, Yung-Song

    2009-03-01

    Cochlear implantation via the scala vestibuli is a viable approach in those with ossification in the scala tympani. With extended cochlear implant experience, there is no significant difference in the mapping parameters and auditory performance between those implanted via scala vestibuli and via scala tympani. To assess the clinical outcomes of cochlear implantation via scala vestibuli. In a cohort follow-up study, 11 prelingually deafened children who received cochlear implantation between age 3 and 10 years through the scala vestibuli served as participants. The mapping parameters (i.e. comfortable level (C), threshold level (T), dynamic range) and auditory performance of each participant were evaluated following initial cochlear implant stimulation, then at 3 month intervals for 2 years, then semi-annually. The follow-up period lasted for 9 years 9 months on average, with a minimum of 8 years 3 months. The clinical results of the mapping parameters and auditory performance of children implanted via the scala vestibuli were comparative to those who were implanted via the scala tympani. No balance problem was reported by any of these patients. One child exhibited residual low frequency hearing after implantation.

  10. Cochlear implants and spoken language processing abilities: review and assessment of the literature.

    Science.gov (United States)

    Peterson, Nathaniel R; Pisoni, David B; Miyamoto, Richard T

    2010-01-01

    Cochlear implants (CIs) process sounds electronically and then transmit electric stimulation to the cochlea of individuals with sensorineural deafness, restoring some sensation of auditory perception. Many congenitally deaf CI recipients achieve a high degree of accuracy in speech perception and develop near-normal language skills. Post-lingually deafened implant recipients often regain the ability to understand and use spoken language with or without the aid of visual input (i.e. lip reading). However, there is wide variation in individual outcomes following cochlear implantation, and some CI recipients never develop useable speech and oral language skills. The causes of this enormous variation in outcomes are only partly understood at the present time. The variables most strongly associated with language outcomes are age at implantation and mode of communication in rehabilitation. Thus, some of the more important factors determining success of cochlear implantation are broadly related to neural plasticity that appears to be transiently present in deaf individuals. In this article we review the expected outcomes of cochlear implantation, potential predictors of those outcomes, the basic science regarding critical and sensitive periods, and several new research directions in the field of cochlear implantation.

  11. The contribution of short-term memory capacity to reading ability in adolescents with cochlear implants.

    Science.gov (United States)

    Edwards, Lindsey; Aitkenhead, Lynne; Langdon, Dawn

    2016-11-01

    This study aimed to establish the relationship between short-term memory capacity and reading skills in adolescents with cochlear implants. A between-groups design compared a group of young people with cochlear implants with a group of hearing peers on measures of reading, and auditory and visual short-term memory capacity. The groups were matched for non-verbal IQ and age. The adolescents with cochlear implants were recruited from the Cochlear Implant Programme at a specialist children's hospital. The hearing participants were recruited from the same schools as those attended by the implanted adolescents. Participants were 18 cochlear implant users and 14 hearing controls, aged between 12 and 18 years. All used English as their main language and had no significant learning disability or neuro-developmental disorder. Short-term memory capacity was assessed in the auditory modality using Forward and Reverse Digit Span from the WISC IV UK, and visually using Forward and Reverse Memory from the Leiter-R. Individual word reading, reading comprehension and pseudoword decoding were assessed using the WIAT II UK. A series of ANOVAs revealed that the adolescents with cochlear implants had significantly poorer auditory short-term memory capacity and reading skills (on all measures) compared with their hearing peers. However, when Forward Digit Span was entered into the analyses as a covariate, none of the differences remained statistically significant. Deficits in immediate auditory memory persist into adolescence in deaf children with cochlear implants. Short-term auditory memory capacity is an important neurocognitive process in the development of reading skills after cochlear implantation in childhood that remains evident in later adolescence. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Aspects of Music with Cochlear Implants – Music Listening Habits and Appreciation in Danish Cochlear Implant Users

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Hansen, Mads; Sørensen, Stine Derdau

    Cochlear implant users differ significantly from their normal hearing peers when it comes to perception of music. Several studies have shown that structural features – such as rhythm, timbre, and pitch – are transmitted less accurately through an implant. However, we cannot predict personal...... music less post-implantation than prior to their hearing loss. Nevertheless, a large majority of CI listeners either prefer music over not hearing music at all or find music as pleasant as they recall it before their hearing loss, or more so....... enjoyment of music solely as a function of accuracy of perception. But can music be pleasant with a cochlear implant at all? Our aim here was to gather information of both music enjoyment and listening habits before the onset of hearing loss and post-operation from a large, representative sample of Danish...

  13. Listening Effort With Cochlear Implant Simulations

    NARCIS (Netherlands)

    Pals, Carina; Sarampalis, Anastasios; Başkent, Deniz

    2013-01-01

    Purpose: Fitting a cochlear implant (CI) for optimal speech perception does not necessarily optimize listening effort. This study aimed to show that listening effort may change between CI processing conditions for which speech intelligibility remains constant. Method: Nineteen normal-hearing

  14. Identification and treatment of variation of extrahepatic bile duct in laparoscopic cholecystectomy

    Directory of Open Access Journals (Sweden)

    PENG Lei

    2015-10-01

    Full Text Available ObjectiveTo investigate the identification and treatment of variation of extrahepatic bile duct in laparoscopic cholecystectomy (LC, and to reduce the occurrence of bile duct injury. MethodsThis study included 60 patients who received LC in the People′s Hospital of Caidian District in Wuhan and had structural variation of extrahepatic bile duct found during the operation from January 2012 to January 2014. The clinical data were retrospectively analyzed, and the intraoperative and postoperative conditions were summarized. ResultsDuring operation, cystic duct variation was found in 32 cases, abnormal position of the point where the cystic duct joins the extrahepatic bile duct in 20 cases, the cystic duct and the common hepatic duct having the common wall before joining the common bile duct in 2 cases, aberrant bile duct in the gallbladder bed in 2 cases, and accessory hepatic duct in 4 cases. Fifty-one patients (85% successfully underwent LC; 9 patients (15% were converted to open surgery. All patients finished surgery successfully. There were 2 cases of postoperative complications; one patient developed residual stones in the bile duct, and bile leakage occurred in the other patient at one week after LC, who recovered after reoperation. All patients were cured and discharged, without severe complications such as intraperitoneal hemorrhage, infection, and intestinal injury. ConclusionIdentifying the structural variation of extrahepatic bile duct, dissecting the Calot′s triangle meticulously, and determining the type of variation of extrahepatic bile duct play important roles in LC and significantly reduce the incidence of bile duct injury.

  15. Advancing Binaural Cochlear Implant Technology

    Directory of Open Access Journals (Sweden)

    Mathias Dietz

    2015-12-01

    Full Text Available This special issue contains a collection of 13 papers highlighting the collaborative research and engineering project entitled Advancing Binaural Cochlear Implant Technology—ABCIT—as well as research spin-offs from the project. In this introductory editorial, a brief history of the project is provided, alongside an overview of the studies.

  16. Meningitis after cochlear implantation in Mondini malformation.

    Science.gov (United States)

    Page, E L; Eby, T L

    1997-01-01

    Although the potential for CSF leakage and subsequent meningitis after cochlear implantation in the malformed cochlea has been recognized, this complication has not been previously reported. We report a case of CSF otorhinorrhea and meningitis after minor head trauma developing 2 years after cochlear implantation in a child with Mondini malformation. Leakage of CSF was identified from the cochleostomy around the electrode of the implant, and this leak was sealed with a temporalis fascia and muscle plug. Although this complication appears to be rare, care must be taken to seal the cochleostomy in children with inner ear malformations at the initial surgery, and any episode of meningitis after surgery must be thoroughly investigated to rule out CSF leakage from the labyrinth.

  17. Bile duct obstruction

    Science.gov (United States)

    ... Tumors that have spread to the biliary system Liver and bile duct worms (flukes) The risk factors include: History of ... Increased bilirubin level Increased alkaline phosphatase level Increased liver enzymes The ... CT scan Endoscopic retrograde cholangiopancreatography ( ...

  18. Pancreatic-duct-lavage cytology in candidates for surgical resection of branch-duct intraductal papillary mucinous neoplasm of the pancreas: should the International Consensus Guidelines be revised?

    Science.gov (United States)

    Sai, Jin Kan; Suyama, Masafumi; Kubokawa, Yoshihiro; Watanabe, Sumio; Maehara, Tadayuki

    2009-03-01

    The International Consensus Guidelines are helpful for the management of branch-duct intraductal papillary mucinous neoplasms (IPMNs), because they allow us to exclude malignancy. However, it is not possible to predict malignancy with certainty, and further preoperative differentiation between benign and malignant IPMNs is required to avoid the false-positive results. To examine the usefulness of pancreatic-duct-lavage cytology by using an originally designed double-lumen catheter for discriminating benign and malignant IPMNs of the branch-duct type in candidates for surgical resection based on the International Consensus Guidelines. Pancreatic-duct-lavage cytology was investigated in 24 patients with branch-duct IPMNs who underwent surgical resection based on the International Consensus Guidelines, namely, they either had intramural nodules or the ectatic branch duct was >30 mm in diameter. Single-center retrospective study. Academic medical center. The sensitivity and specificity of pancreatic-duct-lavage cytology for discriminating benign from malignant IPMNs. More than 30 mL of pancreatic-duct-lavage fluid was obtained from each patient, and there were no patients with noninformative results. The sensitivity, specificity, positive predictive value, and negative predictive value of the cytologic diagnosis were 78%, 93%, 88%, and 88%, respectively. Single-center and small number of patients. Pancreatic-duct-lavage cytology can improve differentiation between benign and malignant IPMNs of the branch-duct type in candidates for surgical resection based on the International Consensus Guidelines.

  19. The Role of MRI in Diagnosing Neurovascular Compression of the Cochlear Nerve Resulting in Typewriter Tinnitus.

    Science.gov (United States)

    Bae, Y J; Jeon, Y J; Choi, B S; Koo, J-W; Song, J-J

    2017-06-01

    Typewriter tinnitus, a symptom characterized by paroxysmal attacks of staccato sounds, has been thought to be caused by neurovascular compression of the cochlear nerve, but the correlation between radiologic evidence of neurovascular compression of the cochlear nerve and symptom presentation has not been thoroughly investigated. The purpose of this study was to examine whether radiologic evidence of neurovascular compression of the cochlear nerve is pathognomonic in typewriter tinnitus. Fifteen carbamazepine-responding patients with typewriter tinnitus and 8 control subjects were evaluated with a 3D T2-weighted volume isotropic turbo spin-echo acquisition sequence. Groups 1 (16 symptomatic sides), 2 (14 asymptomatic sides), and 3 (16 control sides) were compared with regard to the anatomic relation between the vascular loop and the internal auditory canal and the presence of neurovascular compression of the cochlear nerve with/without angulation/indentation. The anatomic location of the vascular loop was not significantly different among the 3 groups (all, P > .05). Meanwhile, neurovascular compression of the cochlear nerve on MR imaging was significantly higher in group 1 than in group 3 ( P = .032). However, considerable false-positive (no symptoms with neurovascular compression of the cochlear nerve on MR imaging) and false-negative (typewriter tinnitus without demonstrable neurovascular compression of the cochlear nerve) findings were also observed. Neurovascular compression of the cochlear nerve was more frequently detected on the symptomatic side of patients with typewriter tinnitus compared with the asymptomatic side of these patients or on both sides of control subjects on MR imaging. However, considering false-positive and false-negative findings, meticulous history-taking and the response to the initial carbamazepine trial should be regarded as more reliable diagnostic clues than radiologic evidence of neurovascular compression of the cochlear nerve.

  20. Percutaneous treatment of benign bile duct strictures

    Energy Technology Data Exchange (ETDEWEB)

    Koecher, Martin [Department of Radiology, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic)]. E-mail: martin.kocher@seznam.cz; Cerna, Marie [Department of Radiology, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic); Havlik, Roman [Department of Surgery, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic); Kral, Vladimir [Department of Surgery, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic); Gryga, Adolf [Department of Surgery, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic); Duda, Miloslav [Department of Surgery, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic)

    2007-05-15

    Purpose: To evaluate long-term results of treatment of benign bile duct strictures. Materials and methods: From February 1994 to November 2005, 21 patients (9 men, 12 women) with median age of 50.6 years (range 27-77 years) were indicated to percutaneous treatment of benign bile duct stricture. Stricture of hepatic ducts junction resulting from thermic injury during laparoscopic cholecystectomy was indication for treatment in one patient, stricture of hepaticojejunostomy was indication for treatment in all other patients. Clinical symptoms (obstructive jaundice, anicteric cholestasis, cholangitis or biliary cirrhosis) have appeared from 3 months to 12 years after surgery. Results: Initial internal/external biliary drainage was successful in 20 patients out of 21. These 20 patients after successful initial drainage were treated by balloon dilatation and long-term internal/external drainage. Sixteen patients were symptoms free during the follow-up. The relapse of clinical symptoms has appeared in four patients 9, 12, 14 and 24 months after treatment. One year primary clinical success rate of treatment for benign bile duct stricture was 94%. Additional two patients are symptoms free after redilatation (15 and 45 months). One patient is still in treatment, one patient died during secondary treatment period without interrelation with biliary intervention. The secondary clinical success rate is 100%. Conclusion: Benign bile duct strictures of hepatic ducts junction or biliary-enteric anastomosis are difficult to treat surgically and endoscopically inaccessible. Percutaneous treatment by balloon dilatation and long-term internal/external drainage is feasible in the majority of these patients. It is minimally invasive, safe and effective.

  1. Fluid flow in a spiral microfluidic duct

    Science.gov (United States)

    Harding, Brendan; Stokes, Yvonne

    2018-04-01

    We consider the steady, pressure driven flow of a viscous fluid through a microfluidic device having the geometry of a planar spiral duct with a slowly varying curvature and height smaller than width. For this problem, it is convenient to express the Navier-Stokes equations in terms of a non-orthogonal coordinate system. Then, after applying appropriate scalings, the leading order equations admit a relatively simple solution in the central region of the duct cross section. First-order corrections with respect to the duct curvature and aspect ratio parameters are also obtained for this region. Additional correction terms are needed to ensure that no slip and no penetration conditions are satisfied on the side walls. Our solutions allow for a top wall shape that varies with respect to the radial coordinate which allows us to study the flow in a variety of cross-sectional shapes, including trapezoidal-shaped ducts that have been studied experimentally. At leading order, the flow is found to depend on the local height and slope of the top wall within the central region. The solutions are compared with numerical approximations of a classical Dean flow and are found to be in good agreement for a small duct aspect ratio and a slowly varying and small curvature. We conclude that the slowly varying curvature typical of spiral microfluidic devices has a negligible impact on the flow in the sense that locally the flow does not differ significantly from the classical Dean flow through a duct having the same curvature.

  2. The Canadian residential duct and chimney survey

    Energy Technology Data Exchange (ETDEWEB)

    Fugler, D.

    2003-12-01

    A study was conducted in 1989 to better understand the thermal performance of ducts and chimneys in houses. The objective was to address the problems associated with insufficient airflow and backdrafting of combustion gases resulting from malfunctioning fans, furnaces and fireplaces. The Duct Test Rig was used to measure and recorded airflows and heat losses in a variety of ducts and chimneys in a representative mix of houses in Vancouver, Kelowna, Winnipeg, Calgary, Toronto, London, Montreal, Quebec City, Halifax, Fredericton and Ottawa. Bath, kitchen, clothes dryer and central vacuum exhaust fans were tested to determine how performance is affected by fan age, accumulations of dust, grease, bugs and installation methods. Results indicate that there is no statistical difference between axial or centrifugal fans. The greatest problem appeared to be with low flows, high leakage rates, and poor conditions of bathroom fans. Many kitchen fans were found to be blocked at the inlet by cooking grease. The exhaust flows depended greatly on the condition of the backdraft damper. Dryer exhaust airflow was typically less than the 75 L/s specified by manufacturers, but even old dryers performed relatively well. All types of chimneys were tested for different positive hood pressures, airflow lost through leakage, and thermal characteristics. Airflow was found to vary depending on the type and area of the flue and the presence of a cap. For heating systems, the low duct efficiency was due mostly to duct leakage, radiation losses and restrictive ducts and registers. The findings of this testing program are still valid today. 3 tabs.

  3. Experiments and calculations on neutron streaming through bent ducts

    Energy Technology Data Exchange (ETDEWEB)

    Kloosterman, J.L.; Hoogenboom, J.E. (Delft Univ. of Technology (Netherlands). Interfaculty Reactor Inst.); Zsolnay, E.M.

    1993-07-01

    Neutron spectra in a cylindrical straight duct and in bent ducts with angles of 30deg, 60deg and 90deg have been measured by the multiple foil activation and thermoluminescence dosimetry methods. Two-dimensional discrete ordinates and three-dimensional Monte Carlo calculations are executed, and the results are compared with the measurements. The flow rate at the duct entrance calculated by the DOT3.5 code is underestimated by approximately 30 %, due to a conversion of the core and reflector geometry from XY to RZ geometry. The fast neutron flux in the ducts is underestimated by 20 % by the MORSE-SGC/S code due to a too coarse angular mesh of the source, which does not properly represent the actual angular distribution of the fast flux, which is highly peaked forwardly into the ducts. The thermal neutron flux was over-estimated by the Monte Carlo calculation. A method is proposed to calculate the angular distribution of the flow rate at the duct entrance and to calculate the source strength and the angular distribution of the flow rate at the entrance of the second leg of the duct. The results are compared with those of the transport calculations. Generally, the agreement is quite satisfactory. (author).

  4. Phonological working memory and its relationship with language abilities in children with cochlear implants

    Directory of Open Access Journals (Sweden)

    Fatemeh Haresabadi

    2014-12-01

    Full Text Available Background and Aim: Many studies have demonstrated a close relationship between phonological working memory and language abilities in normal children and children with language developmental disorders, such as those with cochlear implants. A review of these studies would clarify communication and learning in such children and provide more comprehensive information regarding their education and treatment. In this study, the characteristics of phonological working memory and its relationship with language abilities in children with cochlear implants was examined.Recent Findings: In this study, the authors studied the characteristics of phonological working memory and its relationship with language abilities of children with cochlear implants. These studies showed that in addition to demographic variables, phonological working memory is a factor that affects language development in children with cochlear implants. Children with cochlear implants typically have a shorter memory span.Conclusion: It is thought that the deficiency in primary auditory sensory input and language stimulation caused by difficulties in the processing and rehearsal of auditory information in phonological working memory is the main cause of the short memory span in such children. Conversely, phonological working memory problems may have adverse effects on the language abilities in such children. Therefore, to provide comprehensive and appropriate treatment for children with cochlear implants, the reciprocal relationship between language abilities and phonological working memory should be considered.

  5. Spatial channel interactions in cochlear implants

    Science.gov (United States)

    Tang, Qing; Benítez, Raul; Zeng, Fan-Gang

    2011-08-01

    The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies greatly in individuals and is still limited in background noise, tonal language understanding, and music perception. One main cause for the individual variability and the limited performance in cochlear implants is spatial channel interaction from the stimulating electrodes to the auditory nerve and brain. Here we systematically examined spatial channel interactions at the physical, physiological, and perceptual levels in the same five modern cochlear implant subjects. The physical interaction was examined using an electric field imaging technique, which measured the voltage distribution as a function of the electrode position in the cochlea in response to the stimulation of a single electrode. The physiological interaction was examined by recording electrically evoked compound action potentials as a function of the electrode position in response to the stimulation of the same single electrode position. The perceptual interactions were characterized by changes in detection threshold as well as loudness summation in response to in-phase or out-of-phase dual-electrode stimulation. To minimize potentially confounding effects of temporal factors on spatial channel interactions, stimulus rates were limited to 100 Hz or less in all measurements. Several quantitative channel interaction indexes were developed to define and compare the width, slope and symmetry of the spatial excitation patterns derived from these physical, physiological and perceptual measures. The electric field imaging data revealed a broad but uniformly asymmetrical intracochlear electric field pattern, with the apical side producing a wider half-width and shallower slope than the basal

  6. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  7. [Cochlear implant in children: rational, indications and cost/efficacy].

    Science.gov (United States)

    Martini, A; Bovo, R; Trevisi, P; Forli, F; Berrettini, S

    2013-06-01

    A cochlear implant (CI) is a partially implanted electronic device that can help to provide a sense of sound and support speech to severely to profoundly hearing impaired patients. It is constituted by an external portion, that usually sits behind the ear and an internal portion surgically placed under the skin. The external components include a microphone connected to a speech processor that selects and arranges sounds pucked up by the microphone. This is connected to a transmitter coil, worn on the side of the head, which transmits data to an internal receiver coil placed under the skin. The received data are delivered to an array of electrodes that are surgically implanted within the cochlea. The primary neural targets of the electrodes are the spiral ganglion cells which innervate fibers of the auditory nerve. When the electrodes are activated by the signal, they send a current along the auditory nerve and auditory pathways to the auditory cortex. Children and adults who are profoundly or severely hearing impaired can be fitted with cochlear implants. According to the Food and Drug Administration, approximately 188,000 people worldwide have received implants. In Italy it is extimated that there are about 6-7000 implanted patients, with an average of 700 CI surgeries per year. Cochlear implantation, followed by intensive postimplantation speech therapy, can help young children to acquire speech, language, and social skills. Early implantation provides exposure to sounds that can be helpful during the critical period when children learn speech and language skills. In 2000, the Food and Drug Administration lowered the age of eligibility to 12 months for one type of CI. With regard to the results after cochlear implantation in relation to early implantation, better linguistic results are reported in children implanted before 12 months of life, even if no sufficient data exist regarding the relation between this advantage and the duration of implant use and how long

  8. Pancreaticobiliary duct changes of periampullary carcinomas: Quantitative analysis at MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Dong Sheng, E-mail: victoryhope@163.com [Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China); Department of Radiology, No.4 West China Teaching Hospital of Sichuan University, Chengdu 610041 (China); Chen, Wei Xia, E-mail: wxchen25@126.com [Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China); Wang, Xiao Dong, E-mail: tyfs03yz@163.com [Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China); Acharya, Riwaz, E-mail: riwaz007@hotmail.com [Department of Radiology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China); Jiang, Xing Hua, E-mail: 13881865517@163.com [Department of Pathology, West China Hospital of Sichuan University, Chengdu, Sichuan 610041 (China)

    2012-09-15

    Purpose: To quantitatively analyse the pancreaticobiliary duct changes of periampullary carcinomas with volumetric interpolated breath-hold examination (VIBE) and true fast imaging with steady-state precession (true FISP) sequence, and investigate the value of these findings in differentiation and preoperative evaluation. Materials and methods: Magnetic resonance (MR) images of 71 cases of periampullary carcinomas (34 cases of pancreatic head carcinoma, 16 cases of intrapancreatic bile duct carcinoma and 21 cases of ampullary carcinoma) confirmed histopathologically were analysed. The maximum diameter of the common bile duct (CBD) and main pancreatic duct (MPD), dilated pancreaticobiliary duct angle and the distance from the end of the proximal dilated pancreaticobiliary duct to the major papilla were measured. Analysis of variance and the Chi-squared test were performed. Results: These findings showed significant differences among the three subtypes: the distance from the end of proximal dilated pancreaticobiliary duct to the major papilla and pancreaticobiliary duct angle. The distance and the pancreaticobiliary duct angle were least for ampullary carcinoma among the three subtypes. The percentage of dilated CBD was 94.1%, 93.8%, and 100% for pancreatic head carcinoma, intrapancreatic bile duct carcinoma and ampullary carcinoma, respectively. And that for the dilated MPD was 58.8%, 43.8%, and 42.9%, respectively. Conclusion: Quantitative analysis of the pancreaticobiliary ductal system can provide accurate and objective assessment of the pancreaticobiliary duct changes. Although benefit in differential diagnosis is limited, these findings are valuable in preoperative evaluation for both radical resection and palliative surgery.

  9. Simultaneous Bilateral Cochlear Implantation for a 6-Month Child with a History of Meningitis

    Directory of Open Access Journals (Sweden)

    Kh. M. Diab

    2015-01-01

    Full Text Available The article presents the first case of simultaneous bilateral cochlear implantation for a 6-month child with IV degree sensorineural hearing loss after meningocephalitis in Russia. Despite partial ossification of the cochlear basal turns, the early timing of implantation allowed to fully implant active electrodes to both ears. The simultaneous bilateral cochlear implantation in young children, who had meningitis, is a minimally invasive and highly efficient procedure with good long-term results of oral-aural after-care.

  10. Persistent Mullerian Duct Syndrome (PMDS With Large Intraabdominal Seminoma

    Directory of Open Access Journals (Sweden)

    Della Harigovind

    2017-07-01

    Full Text Available Persistent Mullerian Duct Syndrome, a form of male pseudohermaphroditism is characterized by the presence of the Mullerian duct derivatives in an otherwise phenotypically as well as genotypically normal male. We report a case of large intra abdominal seminoma in a male patient with cryptorchidism, along with persistence of Mullerian duct derivatives (uterus.

  11. Parotid duct laceration repair in two horses : case report

    Directory of Open Access Journals (Sweden)

    A. Olivier

    1998-07-01

    Full Text Available Repair of parotid duct lacerations in 2 horses is described using intraluminal silastic tubing as a stent. The duct was lacerated traumatically at the facial vessel notch (incisura vasorum facialium in the 1st horse, and iatrogenically after removal of an intraluminal sialolith after development of infection within the duct in the 2nd horse. In both cases, a silastic tube was passed retrograde into the duct via the salivary papilla, past the wound until the end lay rostroventral to the parotid salivary gland. The severed salivary ducts and the wounds were sutured. The external portion of the silastic tube was sutured to the skin and the tube left in place. Recovery in the 1st case was uneventful. In the 2nd case a salivary duct/cutaneous fistula formed at a wound distant from the sutured wound, which healed spontaneously. This technique differs from a similar described technique in that the stent tube exits the oral cavity and is attached to the outer skin surface.

  12. The intensity-pitch relation revisited: monopolar versus bipolar cochlear stimulation.

    Science.gov (United States)

    Arnoldner, Christoph; Riss, Dominik; Kaider, Alexandra; Mair, Alois; Wagenblast, Jens; Baumgartner, Wolf-Dieter; Gstöttner, Wolfgang; Hamzavi, Jafar-Sasan

    2008-09-01

    The very high speech perception scores now being achieved with cochlear implants have led to demands for similar levels of achievement in music perception and perception in noisy environments. One of the crucial factors in these fields is pitch perception. The aim of the present study was to investigate the extent to which pitch perception is influenced by the intensity of the stimulus, through the use of different stimulation modes (monopolar, bipolar) and different electrodes (lateral and perimodiolar). Sixteen postlingually deafened patients with an average implant use of 3.1 years were included in this study. All patients were using a Cochlear (CI24M, CI24R, CI24RE) cochlear implant. Subjects were asked to compare the pitch of an intensity-constant reference tone with the pitch of a test tone of varying intensity. The test was repeated for apical, mediocochlear, and basal channel locations, and also for monopolar and bipolar stimulation. It was found that in monopolar stimulation 87.5% and in bipolar stimulation 85.7% of the patients perceived a clear pitch change with changing intensity of the stimulus (Spearman correlation coefficients r 0.3, respectively). A total of 73.1% of these patients perceived lower pitches with increasing intensity, 26.9% reported the opposite effect. No statistically significant difference in the intensity-pitch correlation could be found between mono- and bipolar stimulation. Neither the mean dynamic range nor the type of electrode used was found to be related to the correlation coefficient. Although the majority of today's cochlear implant recipients perform well and the intensity-pitch relation in cochlear implant recipients is still poorly understood, rising demands on speech-coding strategies may soon make a compensation of the pitch shifts desirable. Although the results of our study tend to argue against a peripheral mechanism, the exact origin of this phenomenon remains unclear.

  13. Factors contributing to communication skills development in cochlear implanted children.

    Science.gov (United States)

    Ostojić, Sanja; Djoković, Sanja; Radić-šestić, Marina; Nikolić, Mina; Mikić, Branka; Mirić, Danica

    2015-08-01

    Over the last 10 years more than 300 persons received cochlear implant in Serbia and more than 90% of the recipients were children under 10 years of age. The program of cochlear implantation includes postoperative rehabilitation in which cognitive, integrative and developmental methods are used. The study was conducted to reveal factors affecting communication performance (CP) of cochlear implanted (Cl) children. Special attention was focused on the influence of the duration and intensity of rehabilitation and hearing age on further development of communication skills. A group of 30 CI children (13 boys and 17 girls) aged 2 to 5 years was enrolled in the study. All of the children had average intelligence and no other developmental disorder. They lived in families and attended rehabilitative seances 3 to 5 times a week. Their parents/caregivers answered structured questionnaire about functioning after pediatric cochlear implantation (FAPCI) and the results were the subject of detailed statistical analysis. Analysis of variance did not show any difference between the boys and the girls regarding FAPCI achievements (F(1, 28) = 2.909; p = 0.099) and age aberration in CP score (F(1,28) = 0.114, p = 0.738). Correlation analysis showed a statistically significant difference in FAPCI scores related to hearing age and duration of rehabilitation. Regression analysis (enter method) showed that model consisting of indipendent variables significantly contributed to prediction of overall FAPCI scores and Adjusted R2 value could explain 32% difference in communication skills of participants in this study. Communication skills of CI children evaluated by FAPCI are falling behind normatives for normal hearing children 18.6 months on the average. Hearing age, duration and intensity of rehabilitation have positive predictive value for communication skills development. Later identification of hearing loss and later cochlear implantation lead to delayed development of communication

  14. Cochlear implant with a non-removable magnet: preliminary research at 3-T MRI.

    Science.gov (United States)

    Dubrulle, F; Sufana Iancu, A; Vincent, C; Tourrel, G; Ernst, O

    2013-06-01

    To perform preliminary tests in vitro and with healthy volunteers to determine the 3-T MRI compatibility of a cochlear implant with a non-removable magnet. In the in vitro phase, we tested six implants for temperature changes and internal malfunctioning. We measured the demagnetisation of 65 internal magnets with different tilt angles between the implant's magnetic field (bi) and the main magnetic field (b0). In the in vivo phase, we tested 28 operational implants attached to the scalps of volunteers with the head in three different positions. The study did not find significant temperature changes or electronic malfunction in the implants tested in vitro. We found considerable demagnetisation of the cochlear implant magnets in the in vitro and in vivo testing influenced by the position of the magnet in the main magnetic field. We found that if the bi/b0 angle is 90°, there is demagnetisation in almost 60 % of the cases. When the angle is around 90°, the risk of demagnetisation is low (6.6 %). The preliminary results on cochlear implants with non-removable magnets indicate the need to maintain the contraindication of passage through 3-T MRI. • Magnetic resonance imaging can affect cochlear implants and vice versa. • Demagnetisation of cochlear implant correlates with the angle between bi and b0. • The position of the head in the MRI influences the demagnetisation. • Three-Tesla MRI for cochlear implants is still contraindicated. • However some future solutions are discussed.

  15. Prevention and management of vascular complications in middle ear and cochlear implant surgery.

    Science.gov (United States)

    Di Lella, Filippo; Falcioni, Maurizio; Piccinini, Silvia; Iaccarino, Ilaria; Bacciu, Andrea; Pasanisi, Enrico; Cerasti, Davide; Vincenti, Vincenzo

    2017-11-01

    The objective of this study is to illustrate prevention strategies and management of vascular complications from the jugular bulb (JB) and internal carotid artery (ICA) during middle ear surgery or cochlear implantation. The study design is retrospective case series. The setting is tertiary referral university hospital. Patients were included if presented pre- or intraoperative evidence of high-risk anatomical anomalies of ICA or JB during middle ear or cochlear implant surgery, intraoperative vascular injury, or revision surgery after the previous iatrogenic vascular lesions. The main outcome measures are surgical outcomes and complications rate. Ten subjects were identified: three underwent cochlear implant surgery and seven underwent middle ear surgery. Among the cochlear implant patients, two presented with anomalies of the JB impeding access to the cochlear lumen and one underwent revision surgery for incorrect positioning of the array in the carotid canal. Subtotal petrosectomy was performed in all cases. Anomalies of the JB were preoperatively identified in two patients with attic and external auditory canal cholesteatoma, respectively. In a patient, a high and dehiscent JB was found during myringoplasty, while another underwent revision surgery after iatrogenic injury of the JB. A dehiscent ICA complicated middle ear effusion in one case, while in another case, a carotid aneurysm determined a cholesterol granuloma. Rupture of a pseudoaneurysm of the ICA occurred in a child during second-stage surgery and required permanent balloon occlusion without neurological complications. Knowledge of normal anatomy and its variants and preoperative imaging are the basis for prevention of vascular complications during middle ear or cochlear implant surgery.

  16. Liver and Bile Duct Cancer—Patient Version

    Science.gov (United States)

    Liver cancer includes hepatocellular carcinoma and bile duct cancer (cholangiocarcinoma). Risk factors for HCC include chronic infection with hepatitis B or C and cirrhosis of the liver. Start here to find information on liver and bile duct cancer treatment, causes and prevention, screening, research, and statistics.

  17. American parent perspectives on quality of life in pediatric cochlear implant recipients.

    Science.gov (United States)

    Kumar, Roshini; Warner-Czyz, Andrea; Silver, Cheryl H; Loy, Betty; Tobey, Emily

    2015-01-01

    Cochlear implantation influences not only communication but also psychosocial outcomes in children with severe to profound hearing loss. Focusing on issues specific to cochlear implantation (e.g., self-reliance, social relations, education, effects of implantation, and supporting the child) may provide a more accurate and relative view of functional status of pediatric cochlear implant (CI) recipients. The present study analyzes parental perspectives of CI-specific health-related quality of life (HRQoL) in children with CIs to determine (a) if parents differentially rate their child's quality of life according to psychosocial domain (e.g., communication, self-reliance, education); (b) if associations exist between quality of life domains specific to cochlear implantation in pediatric implant recipients; and (c) if demographic variables (i.e., chronologic age, age at cochlear implantation, duration of device experience) mediate parent ratings of quality of life in pediatric CI recipients. Parents of 33 children with CIs (mean age, 9.85 years; mean age of CI activation, 2.47 years; mean device experience, 7.47 years) completed a validated condition-specific questionnaire, Children With Cochlear Implants: Parental Perspectives. Parents positively rated most HRQoL domains, although education and effects of implantation received significantly less positive ratings (p self-reliance, and well-being) significantly correlated with at least 5 other domains, suggesting that positivity in one domain co-occurs with positivity in other domains. Demographic variables (chronologic age, CI activation age, and duration of CI use) did not correlate significantly with psychosocial outcomes; rather, parents reported positive HRQoL and successful functional use of CI across demographic variables. Parents of children and adolescents with CIs rate overall HRQoL positively across psychosocial domains. Significantly less positive ratings of education and effects of implantation may result

  18. Submandibular duct sialolithiasis an unusual presentation

    International Nuclear Information System (INIS)

    Shafi, M.; Jafferi, S.; Jafferi, S.

    2006-01-01

    Multiple calculi in a submandibular gland duct is an uncommon occurrence. One such case occurring in a young boy of 25 years is reported here where thirteen very small stones of 1-3 mm of maximum diameter were lined up in the Wharton's duct in such a way that they were difficult to appreciate on inspection and palpation. Successful exploration was done in two steps. (author)

  19. Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts

    Energy Technology Data Exchange (ETDEWEB)

    Beal, D. [BA-PIRC, Cocoa, FL (United States); McIlvaine, J. [BA-PIRC, Cocoa, FL (United States); Fonorow, K. [BA-PIRC, Cocoa, FL (United States); Martin, E. [BA-PIRC, Cocoa, FL (United States)

    2011-11-01

    This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces.

  20. Evaluation of PEGIT duct connection system

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Brenner, Douglas E.; Sherman, Max H.; Dickerhoff, Darryl J.

    2003-08-01

    Most air duct system components are assembled in the field and are mechanically fastened by sheet metal screws (for sheet metal-to-sheet metal) or by drawbands (for flex duct-to-sheet metal). Air sealing is separate from this mechanical fastening and is usually achieved using tape or mastic products after mechanical fastening. Field observations have shown that mechanical fastening rarely meets code or manufacturers requirements and that sealing procedures are similarly inconsistent. To address these problems, Proctor Engineering Group (PEG) is developing a system of joining ducts (called PEGIT) that combines the mechanical fastening and sealing into a single self-contained procedure. The PEGIT system uses a shaped flexible seal between specially designed sheet metal duct fittings to both seal and fasten duct sections together. Figure 1 shows the inner duct fitting complete with rubber seal. This seal provides the air seal for the completed fitting and is shaped to allow the inner and outer fittings to slide together, and then to lock the fittings in place. The illustration in Figure 2 shows the approximate cross section of the rubber seal that shows how the seal has a lip that is angled backwards. This angled lip allows the joint to be pushed together by folding flat but then its long axis makes it stiff in the pulling apart direction. This study was undertaken to assist PEG in some of the design aspects of this system and to test the performance of the PEGIT system. This study was carried out in three phases. The initial phase evaluated the performance of a preliminary seal design for the PEGIT system. After the first phase, the seal was redesigned and this new seal was evaluated in the second phase of testing. The third phase performed more detailed testing of the second seal design to optimize the production tolerances of the sheet metal fittings. This report summarizes our findings from the first two phases and provides details about the third phase of testing.

  1. Assessment of auditory cortical function in cochlear implant patients using 15O PET

    International Nuclear Information System (INIS)

    Young, J.P.; O'Sullivan, B.T.; Gibson, W.P.; Sefton, A.E.; Mitchell, T.E.; Sanli, H.; Cervantes, R.; Withall, A.; Royal Prince Alfred Hospital, Sydney,

    1998-01-01

    Full text: Cochlear implantation has been an extraordinarily successful method of restoring hearing and the potential for full language development in pre-lingually and post-lingually deaf individuals (Gibson 1996). Post-lingually deaf patients, who develop their hearing loss later in life, respond best to cochlear implantation within the first few years of their deafness, but are less responsive to implantation after several years of deafness (Gibson 1996). In pre-lingually deaf children, cochlear implantation is most effect in allowing the full development language skills when performed within a critical period, in the first 8 years of life. These clinical observations suggest considerable neural plasticity of the human auditory cortex in acquiring and retaining language skills (Gibson 1996, Buchwald 1990). Currently, electrocochleography is used to determine the integrity of the auditory pathways to the auditory cortex. However, the functional integrity of the auditory cortex cannot be determined by this method. We have defined the extent of activation of the auditory cortex and auditory association cortex in 6 normal controls and 6 cochlear implant patients using 15 O PET functional brain imaging methods. Preliminary results have indicated the potential clinical utility of 15 O PET cortical mapping in the pre-surgical assessment and post-surgical follow up of cochlear implant patients. Copyright (1998) Australian Neuroscience Society

  2. A longitudinal study of the bilateral benefit in children with bilateral cochlear implants.

    Science.gov (United States)

    Asp, Filip; Mäki-Torkko, Elina; Karltorp, Eva; Harder, Henrik; Hergils, Leif; Eskilsson, Gunnar; Stenfelt, Stefan

    2015-02-01

    To study the development of the bilateral benefit in children using bilateral cochlear implants by measurements of speech recognition and sound localization. Bilateral and unilateral speech recognition in quiet, in multi-source noise, and horizontal sound localization was measured at three occasions during a two-year period, without controlling for age or implant experience. Longitudinal and cross-sectional analyses were performed. Results were compared to cross-sectional data from children with normal hearing. Seventy-eight children aged 5.1-11.9 years, with a mean bilateral cochlear implant experience of 3.3 years and a mean age of 7.8 years, at inclusion in the study. Thirty children with normal hearing aged 4.8-9.0 years provided normative data. For children with cochlear implants, bilateral and unilateral speech recognition in quiet was comparable whereas a bilateral benefit for speech recognition in noise and sound localization was found at all three test occasions. Absolute performance was lower than in children with normal hearing. Early bilateral implantation facilitated sound localization. A bilateral benefit for speech recognition in noise and sound localization continues to exist over time for children with bilateral cochlear implants, but no relative improvement is found after three years of bilateral cochlear implant experience.

  3. Measure Guideline: Sealing and Insulating of Ducts in Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R.; Puttagunta, S.

    2011-12-01

    This document begins with a discussion on potential cost and performance benefits of duct sealing and insulating. It continues with a review of typical duct materials and components and the overall procedures for assessing and improving the duct system.

  4. [Cochlear implant in patients with congenital malformation of inner ear].

    Science.gov (United States)

    Han, Dong-yi; Wu, Wen-ming; Xi, Xin; Huang, De-liang; Yang, Wei-yan

    2004-02-01

    To study surgical difficulty and key of the cochlear implant in patients with congenital malformation of inner ear. The cochlear implantations were performed in our department from Jan. 2001 to Apr. 2003 for 18 patients with the malformation of inner ear. In this series, there were 11 cases of large vestibular aqueduct syndrome (LVAS), 3 cases of Waardenberg syndrome, 3 cases of Mondini malformation, and 1 case of Usher syndrome. All 18 patients accepted the Nucleus 24-channel cochlear implantations, including Nucleus straight electrode in 13 cases but Contour implantation in 5 cases of LVAS. During operations, leakage of perilymph but not cerebrospinal fluid (CSF) from the open of scala tympani occurred in 11 cases of LVAS, however, the electrode was inserted successfully. The abnormalities of round window occurred in one of 3 cases of Waardenberg syndrome and 3 cases of Mondini malformation, respectively. The cochlear implant could be conducted successfully for the LVAS, and the postoperative effect was same as the ones for the deafness persons with normal development of inner ear. However, for the patients with Mondini syndrome and common cavity, it is important to accurately assess the extent of abnormalities in the inner ear and accompanied malformation before operation, and to evaluate the full extent of difficulties of the operation in order to minimize the risk of CSF leakage and meningitis.

  5. Cochlear implantation in the world's largest medical device market: utilization and awareness of cochlear implants in the United States.

    Science.gov (United States)

    Sorkin, Donna L

    2013-03-01

    Provision of cochlear implants (CIs) for those within the criteria for implantation remains lower in the United States than in some other developed nations. When adults and children are grouped together, the rate of utilization/provision remains low at around 6%. For children, the provision rate is about 50% of those who could benefit from an implant, compared with figures of about 90% for the Flanders part of Belgium, the United Kingdom and other European countries. The probable reasons for this underprovision include: low awareness of the benefits of CIs among the population; low awareness among health-care professionals; the lack of specific referral pathways; some political issues relating to the Deaf Community; and financial issues related to health provision. Such financial issues result in situations which either fail to provide for access to implants or provide too low a level of the necessary funding, especially for low-income individuals covered by public health-care programs such as Medicaid. These issues might be mitigated by adoption and publication of standards for best clinical practices for CI provision, availability of current cost-effectiveness data, and the existence of an organization dedicated to cochlear implantation. Such an organization, the American Cochlear Implant Alliance (ACI Alliance), was recently organized and is described in the paper by Niparko et al. in this Supplement.

  6. Squamous metaplasia of lactiferous ducts (SMOLD)

    International Nuclear Information System (INIS)

    Lo, G.; Dessauvagie, B.; Sterrett, G.; Bourke, A.G.

    2012-01-01

    The aim of this review is to illustrate the mammographic and sonographic appearances of squamous metaplasia of the lactiferous ducts (SMOLD) and to discuss the disease processes of this uncommon breast disease, which shows a strong correlation with smoking. The most common mammographic appearance is of a retro-areolar asymmetrical density. Ultrasonography of the symptomatic breast typically shows a retro-areolar, predominately medial, ill-defined, hypoechoic lesion with either abscess or sinus/fistula formation. Duct dilatation and continuity with lactiferous ducts is commonly seen. Increased vascularity is occasionally seen on colour Doppler ultrasound. Pathology tissue confirmation is always required and this can be by histology of a core biopsy or excision specimen, or fine-needle aspiration (FNA) cytology. Occasionally smears of an associated abundant nipple or sinus discharge may be of value.

  7. Ducted wind turbine optimization : A numerical approach

    NARCIS (Netherlands)

    Dighe, V.V.; De Oliveira Andrade, G.L.; van Bussel, G.J.W.

    2017-01-01

    The practice of ducting wind turbines has shown a beneficial effect on the overall performance, when compared to an open turbine of the same rotor diameter1. However, an optimization study specifically for ducted wind turbines (DWT’s) is missing or incomplete. This work focuses on a numerical

  8. CT study of 17 cases of congenital cochlear abnormality. Embryologic and anatomo-functional relationship

    OpenAIRE

    Maurício, JC; Biscoito, L; Branco, G

    1993-01-01

    In this review of cochlear malformations, 17 cases were studied by CT scan (high resolution-target program) including 10 males and 7 females. The anomaly was bilateral in 12 cases and unilateral in 7 (the latter included 2 Mondini type aplasias and one Michel). The cochlear malformation (whose most frequent expression was the cochlear hypoplasia with 1 or 1 1/2 spires-65% of the cases) was associated to semicircular canals and/or vestibular aqueduct anomaly in 82% of the patients; it was excl...

  9. Common bile duct cancer with massive necrosis mimicking choledochal dilatation on CT

    International Nuclear Information System (INIS)

    Miyake, H.; Matsumoto, S.; Ueda, S.; Maeda, T.; Aikawa, H.; Mori, H.

    1991-01-01

    Carcinomas of the common bile duct are usually seen as dilatation of the bile duct proximal to a solid mass on CT. In the case reported here, the common bile duct cancer itself mimicked dilated common bile duct on CT because of massive necrosis. In a case of simulating dilated common bile duct on CT, and discrepancy between CT and ultrasonography or endoscopic retrograde cholangiopancreatography, a common bile duct cancer with massive necrosis should be included in the differential diagnosis. (orig.)

  10. Cochlear ossification in patients with profound hearing loss following bacterial meningitis

    DEFF Research Database (Denmark)

    Caye-Thomasen, Per; Dam, Mikkel Seidelin; Omland, Silje Haukali

    2012-01-01

    Cochlear ossification following bacterial meningitis is related to causative pathogen, but not age at disease or time point of evaluation. However, progression may occur over time, especially in case of primary signs of ossification.......Cochlear ossification following bacterial meningitis is related to causative pathogen, but not age at disease or time point of evaluation. However, progression may occur over time, especially in case of primary signs of ossification....

  11. Comparison of self-esteem level of adolescents with cochlear implant and normal hearing.

    Science.gov (United States)

    Sahli, Sanem; Belgin, Erol

    2006-09-01

    The purpose of this study is to compare the levels of self-esteem of adolescents with cochlear implants (before and after cochlear implantation) and the ones who have normal hearing. For this purpose, Rosenberg self-esteem scale is applied upon the study group which consists of 30 adolescents with cochlear implant between the ages of 12-19 and upon the control group which consists of 60 adolescents having the similar characteristics. The scale is used to evaluate the level of self-esteem of adolescents with cochlear implant and with normal hearing. At the end of the application, the scores of these two groups which they got according to their answers were compared statistically. When the results were examined, there seemed to be no significant difference statistically between the self-esteem values of the cochlear implant group and the control group. Apart from this, there seemed to be significant difference statistically between the self-esteem values of the before cochlear implantation and control group. In this study, we examined changes in the level of self-esteem according to different variables. As a result, it was found out that in both groups levels of self-esteem was higher for adolescents who had had preschool education, had brothers/sisters, high level of income, whose mother was working and whose father and mother had higher levels of education. On the other hand, the birth sequence and the child's father's profession did not seem to have any effect on the child's level of self-esteem. As a result of these findings, it was thought that cochlear implantation had a positive effect on life quality and it was suggested that the adolescents and their families should get assistance from experts about the characteristics and principles of approaching the child in this period. The adolescent should be directed towards social activities and courses, their positive sides should be supported and further studies should be carried out with different case groups on

  12. Cochlear Implant Outcomes and Genetic Mutations in Children with Ear and Brain Anomalies

    Directory of Open Access Journals (Sweden)

    Micol Busi

    2015-01-01

    Full Text Available Background. Specific clinical conditions could compromise cochlear implantation outcomes and drastically reduce the chance of an acceptable development of perceptual and linguistic capabilities. These conditions should certainly include the presence of inner ear malformations or brain abnormalities. The aims of this work were to study the diagnostic value of high resolution computed tomography (HRCT and magnetic resonance imaging (MRI in children with sensorineural hearing loss who were candidates for cochlear implants and to analyse the anatomic abnormalities of the ear and brain in patients who underwent cochlear implantation. We also analysed the effects of ear malformations and brain anomalies on the CI outcomes, speculating on their potential role in the management of language developmental disorders. Methods. The present study is a retrospective observational review of cochlear implant outcomes among hearing-impaired children who presented ear and/or brain anomalies at neuroimaging investigations with MRI and HRCT. Furthermore, genetic results from molecular genetic investigations (GJB2/GJB6 and, additionally, in selected cases, SLC26A4 or mitochondrial-DNA mutations on this study group were herein described. Longitudinal and cross-sectional analysis was conducted using statistical tests. Results. Between January 1, 1996 and April 1, 2012, at the ENT-Audiology Department of the University Hospital of Ferrara, 620 cochlear implantations were performed. There were 426 implanted children at the time of the present study (who were <18 years. Among these, 143 patients (64 females and 79 males presented ear and/or brain anomalies/lesions/malformations at neuroimaging investigations with MRI and HRCT. The age of the main study group (143 implanted children ranged from 9 months and 16 years (average = 4.4; median = 3.0. Conclusions. Good outcomes with cochlear implants are possible in patients who present with inner ear or brain abnormalities

  13. Aspects of temporal bone anatomy and pathology in conjunction with cochlear implant surgery

    Energy Technology Data Exchange (ETDEWEB)

    Stjernholm, Christina [Karolinska Inst., Stockholm (Sweden). Soedersjukhuset

    2003-07-01

    Cochlear implantation is a treatment for patients with severe sensorineural hearing loss/deafness, who get no help from ordinary hearing aids. The cochlear implant is surgically placed under the skin near the ear and a very thin electrode array is introduced into the cochlea of the inner ear, where it stimulates the remaining nerve fibers. The operation is complicated; it is performed with the aid of a microscope, and involves drilling very close to vital vessels and important nerves. High resolution computed tomography (CT) of the temporal bone is a part of the preoperative evaluation preceding cochlear implantation. It is a method for visualizing the bony structures of the middle and inner ear - to diagnose pathology and to describe the anatomy. The first work concerns CT of the temporal bone and cochlear implant surgery in children with CHARGE association. This is a rare condition with multiple congenital abnormalities, sometimes lethal. Children with CHARGE have different combinations of disabilities, of which impairments of vision and hearing, as well as balance problems and facial palsy can lead to developmental delay. There have been few reports of radiological temporal bone changes and none of cochlear implant surgery for this group. The work includes a report of the findings on preoperative CT and at surgery, as well as postimplant results in two children. A review of the latest diagnostic criteria of CHARGE and the temporal bone changes found in international literature is also included. The conclusion was that certain combinations of temporal bone changes in CHARGE are, if not specific, at least extremely rare in other materials. CT can visualize these changes and be used as a diagnostic tool. This is important, since some of the associated disabilities are not so obvious from the start. Early treatment is vital for the child's development. This work also shows that cochlear implantation may help some of these often very isolated children to

  14. Aspects of temporal bone anatomy and pathology in conjunction with cochlear implant surgery

    International Nuclear Information System (INIS)

    Stjernholm, Christina

    2003-01-01

    Cochlear implantation is a treatment for patients with severe sensorineural hearing loss/deafness, who get no help from ordinary hearing aids. The cochlear implant is surgically placed under the skin near the ear and a very thin electrode array is introduced into the cochlea of the inner ear, where it stimulates the remaining nerve fibers. The operation is complicated; it is performed with the aid of a microscope, and involves drilling very close to vital vessels and important nerves. High resolution computed tomography (CT) of the temporal bone is a part of the preoperative evaluation preceding cochlear implantation. It is a method for visualizing the bony structures of the middle and inner ear - to diagnose pathology and to describe the anatomy. The first work concerns CT of the temporal bone and cochlear implant surgery in children with CHARGE association. This is a rare condition with multiple congenital abnormalities, sometimes lethal. Children with CHARGE have different combinations of disabilities, of which impairments of vision and hearing, as well as balance problems and facial palsy can lead to developmental delay. There have been few reports of radiological temporal bone changes and none of cochlear implant surgery for this group. The work includes a report of the findings on preoperative CT and at surgery, as well as postimplant results in two children. A review of the latest diagnostic criteria of CHARGE and the temporal bone changes found in international literature is also included. The conclusion was that certain combinations of temporal bone changes in CHARGE are, if not specific, at least extremely rare in other materials. CT can visualize these changes and be used as a diagnostic tool. This is important, since some of the associated disabilities are not so obvious from the start. Early treatment is vital for the child's development. This work also shows that cochlear implantation may help some of these often very isolated children to communicate

  15. Design requirement on KALIMER control rod assembly duct

    International Nuclear Information System (INIS)

    Hwang, W.; Kang, H. Y.; Nam, C.; Kim, J. O.; Kim, Y. J.

    1998-03-01

    This document establishes the design guidelines which are needs for designing the control rod assembly duct of the KALIMER as design requirements. it describes control rod assembly duct of the KALIMER and its requirements that includes functional requirements, performance requirements, interfacing systems, design limits and strength requirements, seismic requirements, structural requirements, environmental requirements, reliability and safety requirements, standard and codes, QA programs, and other requirements. The control rod system consists of three parts, which are drive mechanism, drive-line, and absorber bundle. This report deals with the absorber bundle and its outer duct only because the others are beyond the scope of fuel system design. The guidelines for design requirements intend to be used for an improved design of the control rod assembly duct of the KALIMER. (author). 19 refs

  16. Design requirement on KALIMER control rod assembly duct

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, W.; Kang, H. Y.; Nam, C.; Kim, J. O.; Kim, Y. J

    1998-03-01

    This document establishes the design guidelines which are needs for designing the control rod assembly duct of the KALIMER as design requirements. it describes control rod assembly duct of the KALIMER and its requirements that includes functional requirements, performance requirements, interfacing systems, design limits and strength requirements, seismic requirements, structural requirements, environmental requirements, reliability and safety requirements, standard and codes, QA programs, and other requirements. The control rod system consists of three parts, which are drive mechanism, drive-line, and absorber bundle. This report deals with the absorber bundle and its outer duct only because the others are beyond the scope of fuel system design. The guidelines for design requirements intend to be used for an improved design of the control rod assembly duct of the KALIMER. (author). 19 refs.

  17. Technological, biological, and acoustical constraints to music perception in cochlear implant users.

    Science.gov (United States)

    Limb, Charles J; Roy, Alexis T

    2014-02-01

    Despite advances in technology, the ability to perceive music remains limited for many cochlear implant users. This paper reviews the technological, biological, and acoustical constraints that make music an especially challenging stimulus for cochlear implant users, while highlighting recent research efforts to overcome these shortcomings. The limitations of cochlear implant devices, which have been optimized for speech comprehension, become evident when applied to music, particularly with regards to inadequate spectral, fine-temporal, and dynamic range representation. Beyond the impoverished information transmitted by the device itself, both peripheral and central auditory nervous system deficits are seen in the presence of sensorineural hearing loss, such as auditory nerve degeneration and abnormal auditory cortex activation. These technological and biological constraints to effective music perception are further compounded by the complexity of the acoustical features of music itself that require the perceptual integration of varying rhythmic, melodic, harmonic, and timbral elements of sound. Cochlear implant users not only have difficulty perceiving spectral components individually (leading to fundamental disruptions in perception of pitch, melody, and harmony) but also display deficits with higher perceptual integration tasks required for music perception, such as auditory stream segregation. Despite these current limitations, focused musical training programs, new assessment methods, and improvements in the representation and transmission of the complex acoustical features of music through technological innovation offer the potential for significant advancements in cochlear implant-mediated music perception. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Hollow-duct radiation delivery system investigation

    Directory of Open Access Journals (Sweden)

    Kramer D.

    2013-05-01

    Full Text Available Investigation of hollow-duct structure for high-power laser-diode-array radiation delivery into the end-pumped large-aperture gain media is reported. A ray tracing method has been used to evaluate the performance of the structure designed for maximum transmission efficiency and output beam profile homogeneity. Variable hollow-duct lengths as well as emanating angles of laser-diode-array have been taken into account.

  19. Prediction of fan assisted flow in a duct/pipe network

    International Nuclear Information System (INIS)

    Quraishi, M.S.

    1996-01-01

    The commonly used fan+duct model is usually based on a table generated by matching the fan and system characteristic curves with the applied pressure drop across the fan+duct/pipe network and using linear or polynomial interpolation for intermediate values. However, this empirical approach can only handle a single system configuration for each table. If this approach is replaced by an algebraic formulation a general and flexible model can be developed. The algebraic model will be able to account for failure of resistances in the duct/pipe system as well as the failure of duct/pipe at an intermediate location. This paper presents the development of an algebraic model for fan+duct/pipe systems. (author)

  20. An incidence study on thyroglossal duct cysts in adults

    International Nuclear Information System (INIS)

    Kurt, A.; Ortug, C.; Aydar, Y.; Ortug, G.

    2007-01-01

    To investigate the incidence of the asymptomatic thyroglossal duct anomalies and to review the literature and make comments on the significance of this condition. A total of 80 cadavers were dissected in the present study. This study was carried out during 2005, where the cadavers were randomly included from the criminal laboratories of the Ministry of Justice, Republic of Turkey in Istanbul. None of the cadavers had laryngeal and cervical injuries resulting from a trauma or the cause of their death. The examined cadavers included 59 men and 21 females, and their ages were ranged from 35-80 years old. The larynges were removed and fixed in 10% formalin and then dissected. The sections were examined using surgical SMZ 10 Nikon stereomicroscope. We evaluated the presence, localization and diameter of the cysts with regard to age and sex of the cadavers. We observed a total of 12 different localization of thyroglossal ducts and cysts among the 80 dissected cadavers. Ten of these ducts cysts were found in males with an age range of 35-68 years and 2 female cadavers aged 45-65 years. In 6 cases, the thyroglossal ducts and cysts were located in the left of the midline of the neck, while 3 cases were from the right of the midline, and the remaining was located on the midline of the neck. In all cases, thryoglossal ducts and cysts were complete and restricted to the infrahyoid region: all of them had connection with the hyoid bone, but not with the perichondrium of the cartilage. In addition, the thyroglossal ducts have connection with the left lobe of the thyroid glands in 3 cases, one case in the right lobe, and 2 cases with the isthmus of the thyroid gland. Finally in 5 cases thyroglossal ducts were complete and had well developed cysts. Thyroglossal duct remnants are one of the most often seen congenital asymptomatic masses of the neck region (7%). The presence of these duct remnants may lead to abnormal phonation and epithelial carcinomas. Therefore, correlation of

  1. Simplifying cochlear implant speech processor fitting

    NARCIS (Netherlands)

    Willeboer, C.

    2008-01-01

    Conventional fittings of the speech processor of a cochlear implant (CI) rely to a large extent on the implant recipient's subjective responses. For each of the 22 intracochlear electrodes the recipient has to indicate the threshold level (T-level) and comfortable loudness level (C-level) while

  2. Endoscopic stenting in bile duct cancer increases liver volume.

    Science.gov (United States)

    Lee, Chang Hun; Kim, Seong Hun; Kim, In Hee; Kim, Sang Wook; Lee, Soo Teik; Kim, Dae Ghon; Yang, Jae Do; Yu, Hee Chul; Cho, Baik Hwan; Lee, Seung Ok

    2014-09-01

    Objective evaluation tools for assessing the effectiveness of stenting in palliative treatment of malignant biliary obstruction are not satisfactory. Effects of biliary stenting on liver volume change have never been studied. We aimed to use volumetry to analyze liver volume changes after endoscopic stenting in bile duct cancer according to the location and number of stents. Retrospective review. University hospital. Patients with a diagnosis of hilar or distal bile duct cancer and who underwent biliary metal stenting. ERCP with self-expandable metal stent placement. Liver volume change after biliary stenting and its comparison according to the location (hilar vs distal common bile duct) and number (hilar bilateral vs hilar unilateral). There were 60 patients; 31 were treated for hilar bile duct cancer (13 for bilateral stent and 18 for unilateral stent) and 29 for distal bile duct cancer. Overall mean follow-up duration was 11.7 ± 4.9 weeks. Liver volume increased 17.4 ± 24.1%. The rate of liver growth was rapid during the early period from 4 to 8 weeks. Stenting in hilar bile duct cancer tended to increase liver volume more than distal biliary stents (22.5% vs 11.9%, P = .091). In hilar bile duct cancer, unilateral and bilateral stents showed similar liver volume increases (20.1% and 25.8%, respectively; P = .512). Single center, retrospective. Biliary stenting markedly increased liver volume in both hilar and distal bile duct cancer. Our data suggest that liver volume assessment could be a useful tool for evaluating stent efficacy. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  3. Comparison between bilateral cochlear implants and Neurelec Digisonic(®) SP Binaural cochlear implant: speech perception, sound localization and patient self-assessment.

    Science.gov (United States)

    Bonnard, Damien; Lautissier, Sylvie; Bosset-Audoit, Amélie; Coriat, Géraldine; Beraha, Max; Maunoury, Antoine; Martel, Jacques; Darrouzet, Vincent; Bébéar, Jean-Pierre; Dauman, René

    2013-01-01

    An alternative to bilateral cochlear implantation is offered by the Neurelec Digisonic(®) SP Binaural cochlear implant, which allows stimulation of both cochleae within a single device. The purpose of this prospective study was to compare a group of Neurelec Digisonic(®) SP Binaural implant users (denoted BINAURAL group, n = 7) with a group of bilateral adult cochlear implant users (denoted BILATERAL group, n = 6) in terms of speech perception, sound localization, and self-assessment of health status and hearing disability. Speech perception was assessed using word recognition at 60 dB SPL in quiet and in a 'cocktail party' noise delivered through five loudspeakers in the hemi-sound field facing the patient (signal-to-noise ratio = +10 dB). The sound localization task was to determine the source of a sound stimulus among five speakers positioned between -90° and +90° from midline. Change in health status was assessed using the Glasgow Benefit Inventory and hearing disability was evaluated with the Abbreviated Profile of Hearing Aid Benefit. Speech perception was not statistically different between the two groups, even though there was a trend in favor of the BINAURAL group (mean percent word recognition in the BINAURAL and BILATERAL groups: 70 vs. 56.7% in quiet, 55.7 vs. 43.3% in noise). There was also no significant difference with regard to performance in sound localization and self-assessment of health status and hearing disability. On the basis of the BINAURAL group's performance in hearing tasks involving the detection of interaural differences, implantation with the Neurelec Digisonic(®) SP Binaural implant may be considered to restore effective binaural hearing. Based on these first comparative results, this device seems to provide benefits similar to those of traditional bilateral cochlear implantation, with a new approach to stimulate both auditory nerves. Copyright © 2013 S. Karger AG, Basel.

  4. Reconstruction of Bile Duct Injury and Defect with the Round Ligament.

    Science.gov (United States)

    Dokmak, Safi; Aussilhou, Béatrice; Ragot, Emilia; Tantardini, Camille; Cauchy, François; Ponsot, Philippe; Belghiti, Jacques; Sauvanet, Alain; Soubrane, Olivier

    2017-09-01

    Lateral injury of the bile duct can occur after cholecystectomy, bile duct dissection, or exploration. If direct repair is not possible, conversion to bilioenteric anastomosis can be needed with the risk of long-term bile duct infections and associated complications. We developed a new surgical technique which consist of reconstructing the bile duct with the round ligament. The vascularized round ligament is completely mobilized until its origin and used for lateral reconstruction of the bile duct to cover the defect. T tube was inserted and removed after few months. Patency of the bile duct was assessed by cholangiography, the liver function test and magnetic resonance imaging (MRI). Two patients aged 33 and 59 years old underwent lateral reconstruction of the bile duct for defects secondary to choledocotomy for stone extraction or during dissection for Mirizzi syndrome. The defects measured 2 and 3 cm and occupied half of the bile duct circumference. The postoperative course was marked by low output biliary fistula resolved spontaneously. In one patient, the T tube was removed at 3 months after surgery and MRI at 9 months showed strictly normal aspect of the bile duct with normal liver function test. The second patient is going very well 2 months after surgery and the T tube is closed. Lateral reconstruction of the bile duct can be safely achieved with the vascularized round ligament. We will extend our indications to tubular reconstruction.

  5. Anatomic variations in intrahepatic bile ducts in a north Indian population.

    Science.gov (United States)

    Sharma, Vijay; Saraswat, Vivek Anand; Baijal, Sanjay Saran; Choudhuri, Gourdas

    2008-07-01

    In the present study, we described the anatomical variations in the branching patterns of intrahepatic bile ducts (IHD) and determined the frequency of each variation in north Indian patients. There are no data from India. The study group consisted of 253 consecutive patients (131 women) undergoing endoscopic retrograde cholangiograms for different indications. Anatomical variations in IHD were classified according to the branching pattern of the right anterior segmental duct (RASD) and the right posterior segmental duct (RPSD), presence or absence of first-order branch of left hepatic duct (LHD) and of an accessory hepatic duct. Anatomy of the IHD was typical in 52.9% of cases (n = 134), showing triple confluence in 11.46% (n = 29), anomalous drainage of the RPSD into the LHD in 18.2% (n = 46), anomalous drainage of the RPSD into the common hepatic duct (CHD) in 7.1% (n = 18), drainage of the right hepatic duct (RHD) into the cystic duct 0.4% (n = 1), presence of an accessory duct leading to the CHD or RHD in 4.7% (n = 12), individual drainage of the LHD into the RHD or CHD in 2.4% (n = 6), and unclassified or complex variations in 2.7% (n = 7). None had anomalous drainage of RPSD into the cystic duct. The branching pattern of IHD was atypical in 47% patients. The two most common variations were drainage of the RPSD into the LHD (18.2%) and triple confluence of the RASD, RPSD, and LHD (11.5%).

  6. Research on Duct Flow Field Optimisation of a Robot Vacuum Cleaner

    Directory of Open Access Journals (Sweden)

    Xiao-bo Lai

    2011-11-01

    Full Text Available The duct of a robot vacuum cleaner is the length of the flow channel between the inlet of the rolling brush blower and the outlet of the vacuum blower. To cope with the pressure drop problem of the duct flow field in a robot vacuum cleaner, a method based on Pressure Implicit with Splitting of Operators (PRISO algorithm is introduced and the optimisation design of the duct flow field is implemented. Firstly, the duct structure in a robot vacuum cleaner is taken as a research object, with the computational fluid dynamics (CFD theories adopted; a three-dimensional fluid model of the duct is established by means of the FLUENT solver of the CFD software. Secondly, with the k-∊ turbulence model of three-dimensional incompressible fluid considered and the PRISO pressure modification algorithm employed, the flow field numerical simulations inside the duct of the robot vacuum cleaner are carried out. Then, the velocity vector plots on the arbitrary plane of the duct flow field are obtained. Finally, an investigation of the dynamic characteristics of the duct flow field is done and defects of the original duct flow field are analysed, the optimisation of the original flow field has then been conducted. Experimental results show that the duct flow field after optimisation can effectively reduce pressure drop, the feasibility as well as the correctness of the theoretical modelling and optimisation approaches are validated.

  7. Research on Duct Flow Field Optimisation of a Robot Vacuum Cleaner

    Directory of Open Access Journals (Sweden)

    Xiao-bo Lai

    2011-11-01

    Full Text Available The duct of a robot vacuum cleaner is the length of the flow channel between the inlet of the rolling brush blower and the outlet of the vacuum blower. To cope with the pressure drop problem of the duct flow field in a robot vacuum cleaner, a method based on Pressure Implicit with Splitting of Operators (PRISO algorithm is introduced and the optimisation design of the duct flow field is implemented. Firstly, the duct structure in a robot vacuum cleaner is taken as a research object, with the computational fluid dynamics (CFD theories adopted; a three‐dimensional fluid model of the duct is established by means of the FLUENT solver of the CFD software. Secondly, with the k‐ε turbulence model of three‐ dimensional incompressible fluid considered and the PRISO pressure modification algorithm employed, the flow field numerical simulations inside the duct of the robot vacuum cleaner are carried out. Then, the velocity vector plots on the arbitrary plane of the duct flow field are obtained. Finally, an investigation of the dynamic characteristics of the duct flow field is done and defects of the original duct flow field are analysed, the optimisation of the original flow field has then been conducted. Experimental results show that the duct flow field after optimisation can effectively reduce pressure drop, the feasibility as well as the correctness of the theoretical modelling and optimisation approaches are validated.

  8. Projections from the cochlear nuclei in the mustache bat, Pteronotus parnellii

    International Nuclear Information System (INIS)

    Zook, J.M.; Casseday, J.H.

    1985-01-01

    Ascending projections of the cochlear nuclei in the mustache bat were analyzed by anterograde transport of [ 3 H]-leucine and by retrograde transport of HRP. The authors were particularly interested in pathways to two parts of the system: (1) to the medial superior olive, because this nucleus is missing in most echolocating bats, but appears to be present in the mustache bat, and (2) to the intermediate and ventral nuclei of the lateral lemniscus, because these nuclei are hypertrophied and highly differentiated in all echolocating bats that we have examined. The results show a highly systematic projection from the anteroventral cochlear nucleus to all of the auditory nuclei in the brain stem. After an injection of [ 3 H]-leucine in the anterior and dorsal part of the anteroventral cochlear nucleus, presumably in a region sensitive to low frequencies, label is seen in the following locations: ipsilateral to the injection in the lateral part of the lateral superior olive; bilaterally in the dorsal part of the medial superior olive; contralateral to the injection in the dorsal parts of the intermediate and ventral nuclei of the lateral lemniscus; and in the anterolateral part of the central nucleus of the inferior colliculus. After an injection of [ 3 H]-leucine in a posterior part of the anteroventral cochlear nucleus, presumably in a region sensitive to high frequencies, labeling is in the same set of nuclei, but within each nucleus the label is now in a different location. Projections from the entire anteroventral cochlear nucleus to the inferior colliculus are confined to the ventral two-thirds of the central nucleus

  9. Hearing Preservation Outcomes With a Mid-Scala Electrode in Cochlear Implantation.

    Science.gov (United States)

    Hunter, Jacob B; Gifford, René H; Wanna, George B; Labadie, Robert F; Bennett, Marc L; Haynes, David S; Rivas, Alejandro

    2016-03-01

    To evaluate hearing preservation (HP) outcomes in adult cochlear implant recipients with a mid-scala electrode. Tertiary academic center. Adult patients implanted with a mid-scala electrode between May 2013 and July 2015. Cochlear implantation. Age, sex, surgical approach, residual hearing changes post cochlear implantation, HP rates using different published classifications, and speech perception scores. Fifty ears for 47 patients (mean age, 58.2 yr; range, 23-86) were implanted with the electrode. Recognizing that not all patients were true HP candidates and/or underwent generally accepted HP surgical techniques, 39 ears had preoperative low-frequency hearing (audiometric threshold ≤ 85dB HL at 250Hz), 24 preserved acoustic hearing postoperatively (75.0%). Patients who had preserved acoustic hearing were implanted via round window (N = 18), extended round window (N = 4), or via cochleostomy (N = 2) approaches. Mean threshold elevation for low-frequency pure-tone average (125, 250, and 500  Hz) was 20.2  dB after surgery. 43.8% of patients had aidable low-frequency hearing at activation, 30.0% at 6-months postoperatively, and 30.8% 1-year postopera tively. Using a formula outlined by Skarzynski and colleagues, at 6-months postoperatively, 15.0% of patients had complete HP, whereas 40.0% had partial HP. At 1-year, these percentages decreased to 0% and 38.5%, respectively. Age, type of approach, and perioperative steroid use were not correlated with HP outcomes at activation and 6-months postoperatively (p > 0.05). The mid-scala electrode evaluated allows preservation of low-frequency hearing in patients undergoing cochlear implantation at rates and degrees of preservation close to other reports in the cochlear implant literature.

  10. Congenital double bile duct presenting as recurrent cholangitis in a child

    Directory of Open Access Journals (Sweden)

    K.D. Chakravarty

    2015-12-01

    Full Text Available Double common bile duct (DCBD is a rare congenital anomaly. Most of these bile duct anomalies are associated with bile duct stones, anomalous pancreaticobiliary junction (APBJ, pancreatitis and bile duct or gastric cancers. Early detection and treatment is important to avoid long term complications. Surgical resection of the anomalous bile duct and reconstruction of the biliary enteric anastomosis is the treatment of choice. We report a rare case of DCBD anomaly in a girl, who presented with recurrent cholangitis. She had type Va DCBD anomaly. She underwent successful resection of the bile duct and reconstruction of the biliary enteric anastomosis. Preoperative imaging and diagnosis of the congenital biliary anomaly is very important to avoid intraoperative bile duct injury. Review of the literature shows very few cases of type Va DCBD, presenting with either bile duct stones or APBJ.

  11. Anatomic relationship of intrahepatic bile ducts to portal veins revisited

    International Nuclear Information System (INIS)

    Bret, P.M.; Stempel, J.; Atri, M.; Lough, J.O.; Illescas, F.F.

    1987-01-01

    It is well accepted that intrahepatic bile ducts lie in front of corresponding portal vein branches. Since the authors' clinical experience with US was different, they studied 18 normal necropsy cadaver livers. The common bile duct, main portal vein, and hepatic artery were cannulated and injected respectively with air, dilute contrast medium, and mineral oil. The livers were then examined in anatomic position with CT. In the left lobe of the liver, the bile ducts were anterior to the portal vein in seven cases, posterior in seven cases, and were tortuous both anterior and posterior in three cases. In the right lobe, the bile ducts were anterior in nine cases, posterior in five cases, tortuous in one case, and not seen in two cases. In the porta hepatis, the bile ducts were anterior in eight cases, posterior in one case, tortuous in five cases, and not seen in three cases. Histologic specimens confirmed the anterior and posterior location of the bile ducts relative to the portal veins. In conclusion, intrahepatic bile ducts can be either anterior or posterior to the corresponding portal vein branches

  12. Productivity of lexical categories in French-speaking children with cochlear implants.

    Science.gov (United States)

    Le Normand, M-T; Ouellet, C; Cohen, H

    2003-11-01

    The productivity of lexical categories was studied longitudinally in a sample of 17 young hearing-impaired French-speaking children with cochlear implants. Age of implantation ranged from 22 months to 76 months. Spontaneous speech samples were collected at six-month intervals over a period of 36 months, starting at the one-word stage. Four general measures of their linguistic production (number of utterances, verbal fluency, vocabulary, and grammatical production) as well as 36 specific lexical categories, according to the CHILDES codes, were computed in terms of tokens, i.e., total number of words. Cochlear-implanted children (CI) were compared to a French database of normally hearing children aged 2-4 compiled by the first author. Follow-up results indicate that, at the two-year post-implantation follow-up, noun, and verb morphology was significantly impaired. At the three-year follow-up, the cochlear-implanted group had recovered on adjectives, determiners and nouns, main verbs, and auxiliaries. The two groups differed significantly in processing locative adverbs, prepositions, pronouns, and verbs (infinitive verb, modal, and modal lexical), but individual variability within the cochlear-implanted group was substantial. Results are discussed in terms of recovery and developmental trends and variability in the acquisition of lexical categories by French children two years and three years post-implantation.

  13. Are Ducted Mini-Splits Worth It?

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jonathan M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Maguire, Jeffrey B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Metzger, Cheryn E. [Pacific Northwest National Laboratory; Zhang, Jason [Pacific Northwest National Laboratory

    2018-02-01

    Ducted mini-split heat pumps are gaining popularity in some regions of the country due to their energy-efficient specifications and their ability to be hidden from sight. Although product and install costs are typically higher than the ductless mini-split heat pumps, this technology is well worth the premium for some homeowners who do not like to see an indoor unit in their living area. Due to the interest in this technology by local utilities and homeowners, the Bonneville Power Administration (BPA) has funded the Pacific Northwest National Laboratory (PNNL) and the National Renewable Energy Laboratory (NREL) to develop capabilities within the Building Energy Optimization (BEopt) tool to model ducted mini-split heat pumps. After the fundamental capabilities were added, energy-use results could be compared to other technologies that were already in BEopt, such as zonal electric resistance heat, central air source heat pumps, and ductless mini-split heat pumps. Each of these technologies was then compared using five prototype configurations in three different BPA heating zones to determine how the ducted mini-split technology would perform under different scenarios. The result of this project was a set of EnergyPlus models representing the various prototype configurations in each climate zone. Overall, the ducted mini-split heat pumps saved about 33-60% compared to zonal electric resistance heat (with window AC systems modeled in the summer). The results also showed that the ducted mini-split systems used about 4% more energy than the ductless mini-split systems, which saved about 37-64% compared to electric zonal heat (depending on the prototype and climate).

  14. CT findings of thyroglossal duct cyst

    International Nuclear Information System (INIS)

    Kim, Dong Oh; Kim, Hong Soo; So, Hyun Soon; Nam, Mee Young; Choi, Jae Ho; Rhee, Hak Song

    1995-01-01

    The purpose of this study was to evaluate the CT findings of thyroglossal duct cysts. Sixteen patients with pathologically proved thyroglossal duct cysts were included in the study. CT scans were assessed retrospectively for shape, size, location, density of the central portions, septations, rim enhancement, changes in the adjacent fascial planes and investment within the strap muscles in the infrahyoid cysts. Thirteen cases of thyroglossal duct cysts were seen as round or oval cystic masses, two cases of them were seen as irregular-shaped lobulated cystic masses, and one case was seen as ovoid soft tissue mass. The cysts were from 1.4 to 5.7 cm in diameter (mean, 2.6 cm). The cyst was infrahyoid in 15 cases and suprahyoid in one case. The cyst was located in midline in eight cases, off midline in four cases, and both midline and off midline in four cases. The density of the central portions ranged from 15 to 82HU (mean, 32HU). Septations were noted in four cases. Rim enhancement was seen in 14 cases (93%), and heterogeneously enhancing soft tissue mass was seen in one case. In four cases, abnormal fascial planes were observed. All but one of the infrahyoid cysts (14/15) were embedded within the strap muscles, and one case of them was located anteriorly to strap muscles. CT permits one to make the diagnosis a thyroglossal duct cyst with a high degree of accuracy, as it can differentiate thyroglossal duct cysts from the other anterior neck masses by their typical location, characteristic morphology, and investment within the strap muscles

  15. Cochlear implantation in patient with Dandy-walker syndrome.

    Science.gov (United States)

    de Oliveira, Adriana Kosma Pires; Hamerschmidt, Rogerio; Mocelin, Marcos; Rezende, Rodrigo K

    2012-07-01

     Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment.  To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation.  CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of "Dandy-Walker syndrome" for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality.

  16. Cochlear implantation in patient with Dandy-walker syndrome

    Directory of Open Access Journals (Sweden)

    Oliveira, Adriana Kosma Pires de

    2012-01-01

    Full Text Available Introduction: Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment. Objectives: To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation. Case Report: CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of "Dandy-Walker syndrome" for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality.

  17. Audiological findings after multichannel cochlear implantation in patients with Mondini dysplasia.

    Science.gov (United States)

    Munro, K J; George, C R; Haacke, N P

    1996-12-01

    Mondini dysplasia is a congenital malformation of the inner ear. To date, five individuals with this malformation have received cochlear implants at the South of England Cochlear Implant Centre. The aim of this study was to review the audiological findings of these individuals after implantation. The soundfield thresholds after implantation are in the region of 30-40 dB (A). The results of suprathreshold speech recognition tasks show substantial variability in performance but this is no greater than that obtained from implant users with no malformation. All individuals were able to detect and recognize a variety of environmental sounds that would previously have been inaudible. These findings, along with the reported improvement in quality of life, mean that Mondini dysplasia is not a contra-indication for multichannel cochlear implantation. This information will be useful to other centres when considering implantation in similar patients.

  18. Liver and Bile Duct Cancer—Health Professional Version

    Science.gov (United States)

    Liver cancer includes two major types: hepatocellular carcinoma (HCC) and intrahepatic bile duct cancer, also known as cholangiocarcinoma. Find evidence-based information on liver and bile duct cancer treatment, causes and prevention, screening, research, genomics and statistics.

  19. Time course of collagen peak in bile duct-ligated rats

    OpenAIRE

    Tarcin, Orhan; Basaranoglu, Metin; Tahan, Veysel; Tahan, Gülgün; Sücüllü, Ilker; Yilmaz, Nevin; Sood, Gagan; Snyder, Ned; Hilman, Gilbert; Celikel, Cigdem; Tözün, Nurdan

    2011-01-01

    Abstract Background One of the most useful experimental fibrogenesis models is the "bile duct-ligated rats". Our aim was to investigate the quantitative hepatic collagen content by two different methods during the different stages of hepatic fibrosis in bile duct-ligated rats on a weekly basis. We questioned whether the 1-wk or 4-wk bile duct-ligated model is suitable in animal fibrogenesis trials. Methods Of the 53 male Wistar rats, 8 (Group 0) were used as a healthy control group. Bile duct...

  20. Influence of hearing age and understanding verbal instructions in children with cochlear implants

    Directory of Open Access Journals (Sweden)

    Đoković Sanja

    2013-01-01

    Full Text Available Hearing age is defined as a period of using any amplification. Most researches indicate that hearing age influences the developmental rate of auditory and speech-language abilities in deaf children, especially when cochlear implantation was performed before the age of three. This research is aimed at analyzing the influence of hearing age on understanding verbal instructions in children with cochlear implants. The sample consists of 23 children with cochlear implants and 21 children with normal hearing, aged between 4 and 10. Hearing age of children with cochlear implants was between 2 and 7 years. Token Test with toys, adapted for children with hearing impairments, was used to analyze understanding verbal instructions. The results indicate that there are statistically significant differences between children with cochlear implants and children with normal hearing, aged between 4 and 7, on all subtests and the total score regardless of the hearing age (sub1 p<0.001, sub2 p<0.000, sub3 p<0.001, total score p<0.000. No statistically significant differences were determined on any of the subtests in children aged between 7.1 and 10, regardless of the hearing age. Comparative results analysis within the experimental group of children with different hearing age indicates that the difference in understanding verbal instructions between these two groups is not statistically significant.

  1. Internal radiotherapy for hilar bile duct cancer

    International Nuclear Information System (INIS)

    Ryu, Munemasa; Ogino, Takashi; Konishi, Hiroshi

    1999-01-01

    By December 1998, 24 patients with non-resected hilar bile duct cancer (mean age of 74) had received bile duct intracavitary irradiation and 13 patients with residual cancer after resection of hilar bile duct cancer had received postoperative intracavitary irradiation. After they were externally irradiated 30 Gy in total by 15 fractions (2 Gy/time, 5 times in a week), intracavitary irradiation using 192-Ir was given 5 times in total (2 times in a week) from 3 weeks after external irradiation under the condition which dose became 8 Gy in depth of 10 mm from radiation source. The cases of postoperative irradiation had 3 times in total. As for 20 patients of non-resected hilar bile duct cancer without metastasis, 50% survival time was 265 days and there was no 5 year survivor. Fifty percents survival time of 4 patients with metastasis was 113 days. The effect of local control was recognized in 20 patients (83.3%). In 13 patients of postoperative irradiation, 50% survival time was 554 days, and survival rate of 3 years was 28%. (K.H.)

  2. The significance of a hypoplastic bony canal for the cochlear nerve in patients with sensorineural hearing loss: CT and MRI findings

    International Nuclear Information System (INIS)

    Choi, Yoon Jung; Park, Sang Yoo; Kim, Myung Soon; Sung, Ki Jun

    2004-01-01

    The purpose of this study is to evaluate the significance of the hypoplastic canal for the cochlear nerve in patients with sensorineural hearing loss (SNHL) and the relationship between the hypoplastic bony canal and aplasia or hypoplasia of the cochlear nerve. A retrospective review of high resolution temporal CT(HRCT) and MRI findings was conducted. The narrow bony canal of the cochlear nerve and the relative size of the internal auditory canal were correlated with the cochlear nerve deficiency on MRI. The comparative size of the component nerves (facial, cochlear, superior vestibular, inferior vestibular nerve), and the relative size of the internal auditory canal and the bony canal of the cochlear nerve were measured. The clinical history and the results of the clinical examination were reviewed for each patient. High resolution MRI showed aplasia of the common vestibulocochlear nerve in one patient and a deficiency of the cochlear nerve in 9 patients. These abnormalities occurred in association with a prominent narrowing of the canal for the cochlear nerve and a stenosis of the internal auditory canal, which was observed on temporal bone CT in 9 patients with congenital SNHL. Three patients had normal IAC, despite the presence of a hypoplastic cochlear nerve on the side on which they had SNHL. In one patient, the narrowing of the canal for the cochlear nerve and internal auditory canal were not found to be associated with acquired SNHL. The hypoplastic bony canal for the cochlear nerve might be more highly indicative of congenital cochlear nerve deficiency than that of the narrow internal auditory canal, and the position of the crista falciformis should also be carefully

  3. The significance of a hypoplastic bony canal for the cochlear nerve in patients with sensorineural hearing loss: CT and MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yoon Jung; Park, Sang Yoo; Kim, Myung Soon; Sung, Ki Jun [College of Medicine, Yonsei Univ., Wonju (Korea, Republic of)

    2004-04-01

    The purpose of this study is to evaluate the significance of the hypoplastic canal for the cochlear nerve in patients with sensorineural hearing loss (SNHL) and the relationship between the hypoplastic bony canal and aplasia or hypoplasia of the cochlear nerve. A retrospective review of high resolution temporal CT(HRCT) and MRI findings was conducted. The narrow bony canal of the cochlear nerve and the relative size of the internal auditory canal were correlated with the cochlear nerve deficiency on MRI. The comparative size of the component nerves (facial, cochlear, superior vestibular, inferior vestibular nerve), and the relative size of the internal auditory canal and the bony canal of the cochlear nerve were measured. The clinical history and the results of the clinical examination were reviewed for each patient. High resolution MRI showed aplasia of the common vestibulocochlear nerve in one patient and a deficiency of the cochlear nerve in 9 patients. These abnormalities occurred in association with a prominent narrowing of the canal for the cochlear nerve and a stenosis of the internal auditory canal, which was observed on temporal bone CT in 9 patients with congenital SNHL. Three patients had normal IAC, despite the presence of a hypoplastic cochlear nerve on the side on which they had SNHL. In one patient, the narrowing of the canal for the cochlear nerve and internal auditory canal were not found to be associated with acquired SNHL. The hypoplastic bony canal for the cochlear nerve might be more highly indicative of congenital cochlear nerve deficiency than that of the narrow internal auditory canal, and the position of the crista falciformis should also be carefully.

  4. Flow characteristics of developing laminar steady flows in a straight duct connected to a square curved duct

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Hyun Chull [Chosun Univ., Gwangju (Korea, Republic of)

    2005-05-01

    In the present study, the characteristics of developing steady laminar flows of a straight duct connected to a 180 .deg. curved duct were examined in the entrance region through experimental measurement. Flow characteristics such as shear stress distributions, pressure distributions and friction coefficient experimentally in a square cross-sectional straight duct by using the PIV system. For the PIV measurement by particles produced from mosquito coils particles. The experimental data were obtained at 9 points dividing the test sections by 400 mm. Experimental results can be summarized as follows. Critical Reynolds number, Re{sub cr} which indicates transition from laminar steady flow to transition steady flow was 2,150. Shear stress per unit length on the wall was stronger than that in the fully developed flow region. This was attributed to the fact that shear stress and pressure loss in the curvature of a duct were increased. Pressure distributions were gradually decreased irrespective of Reynolds number in the whole test section. This trends were in a good agreement with the reference results. Pipe friction coefficient in the steady state flow region was calculate from method of least squares. The co-relationship between fiction coefficient and Reynolds number was established as follow; {lambda}=56/Re.

  5. A remote joint system for large vacuum ducts

    International Nuclear Information System (INIS)

    Hagmann, D.B.; Coughlan, J.B.

    1983-01-01

    A large remote vacuum duct joining system has been developed for fusion machines that uses several two-jaw screwdriven clamps. The preferred location for clamp installation is inside the vacuum duct where access space is available for the actuating device. It also decreases space needed for handling operations exterior to the duct. The clamp system is unique in that it is low cost, applies force directly over the seal, permits leak testing to the seal annulus, is highly reliable, can be remotely replaced, and is usable on a variety of other applications

  6. [Salivary gland drainage into the thyroglossal duct].

    Science.gov (United States)

    Siem, G; Natvig, K; Kolbenstvedt, A; Lømo, J

    2001-01-20

    Failure in regression of the thyroglossal duct is one of the most common reasons for midline swellings in the neck. Several authors have described recurrent thyroglossal duct remnants with persisting draining sinuses. However, few have described accessory salivary glands that drain into the thyroglossal duct. In this article we report two such cases with midline salivary glands in the floor of the mouth. These two patients were subsequently successfully treated with radical tissue resection in the area between the hyoid bone and foramen cecum. Preoperative fistulography or sinography was useful to demonstrate the ductal ramification of the salivary glands, and use of methylene blue during surgery proved of significant value for the result.

  7. Advances in cochlear implant telemetry: evoked neural responses, electrical field imaging, and technical integrity.

    NARCIS (Netherlands)

    Mens, L.H.M.

    2007-01-01

    During the last decade, cochlear implantation has evolved into a well-established treatment of deafness, predominantly because of many improvements in speech processing and the controlled excitation of the auditory nerve. Cochlear implants now also feature telemetry, which is highly useful to

  8. Hearing experience and receptive vocabulary development in deaf children with cochlear implants.

    Science.gov (United States)

    Fagan, Mary K; Pisoni, David B

    2010-01-01

    This study investigated receptive vocabulary delay in deaf children with cochlear implants. Participants were 23 children with profound hearing loss, ages 6-14 years, who received a cochlear implant between ages 1.4 and 6 years. Duration of cochlear implant use ranged from 3.7 to 11.8 years. Peabody Picture Vocabulary Test, Third Edition (PPVT-III) data were analyzed first by examining children's errors for evidence of difficulty in specific lexical content areas, and second by calculating standard scores with reference to hearing age (HA) (i.e., chronological age [CA]--age at implantation) rather than CA. Participants showed evidence of vocabulary understanding across all PPVT-III content categories with no strong evidence of disproportionate numbers of errors in any specific content area despite below-average mean standard scores. However, whereas mean standard scores were below the test mean established for hearing children when based on CA, they were within the average range for hearing children when calculated based on HA. Thus, children's vocabulary knowledge was commensurate with years of cochlear implant experience, providing support for the role of spoken language experience in vocabulary acquisition.

  9. Visualization of the thoracic duct by lymphoscintigraphy

    International Nuclear Information System (INIS)

    Baulieu, F.; Baulieu, J.L.; Itti, R.; Tours Univ., 37

    1987-01-01

    Imaging of the thoracic duct is usually performed by radiological lymphography. However, this procedure, which uses an oil based dye injected directly into the lymph channels, has some adverse effects. In this paper we note that lymphoscintigraphy, a physiological and non invasive method, may visualize thoracic duct abnormalities, and might be particularly usefull when radiological lymphography is contraindicated. (orig.)

  10. Cochlear implant: the family's perspective.

    Science.gov (United States)

    Vieira, Sheila de Souza; Dupas, Giselle; Chiari, Brasilia Maria

    2018-07-01

    To understand the family's experience of a child who uses a cochlear implant (CI). Specifically, to identify the difficulties, changes, and feelings entailed by deafness and the use of the CI; the coping strategies; and to understand the role of the family for the child with a CI. Qualitative research, using Symbolic Interactionism and Straussian Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semi-structured interview. A total of 9 families (32 individuals) participated in the study. The children's ages ranged from 6 to 11 years old (mean = 8.9 years old). Their experience is described in the following categories: Having to fight for results, Coping with difficult situations, Recognizing that you are not alone, Learning to overcome, and Having one's life restored by the implant. Cochlear implantation changes the direction of the child and the family's life by restoring the child's opportunity to hear and to obtain good results in her personal, social, and academic development. Even after implantation, the child continues to experience difficulties and requires the family's mobilization in order to be successful. The family is the principal actor in the process of the child's rehabilitation.

  11. The comparison of balance performance among children with cochlear implantation, post-aural aid and normal children

    Directory of Open Access Journals (Sweden)

    Arezoo Ahmad pour

    2014-11-01

    Full Text Available Background: This cross-sectional study was carried out to compare balance performance between children with cochlear implants and post-aural aid and normal children. Methods: The present study was done on 67 severe to profound hearing impaired children. Of these, 21 children with an average age of 7 years and 4 months (±1.7 wore cochlear implant, 46 children with an average age of 7 years and 7 months (±1.7 wore post-aural aid and 60 children with an average 8 years and one month (±11 months were considered as a control group. All of the children were tested with the 9-stage balance subtest of Bruininks-Oseretsky Test of Motor Proficiency2 (BOT2. Results: The mean total BOT2 score of hearing impaired children was significantly lower than the normal group (P≤0.001. The mean total BOT2 score among children with cochlear implant, post-aural aids and normal group showed that cochlear implant group significantly performed weaker than the other two groups (P≤0.001. Conclusion: Hearing impaired children particularly children with cochlear implant are exposed to the risk of balance deficit. Hearing impaired children specially those who wear cochlear implants must be screened for vestibular hypofunction.

  12. Dislocation of cochlear implant magnet as a complication following MRI.

    Science.gov (United States)

    Murtojärvi, Sarita; Salonen, Jaakko

    According to current best knowledge, an MRI scan can be performed for patients with cochlear implants. The warnings and recommendations of the implant manufacturers must be followed strictly to prevent complications, such as overheating, migration or demagnetization of the magnet in the implant. We report on a case of cochlear implant magnet dislocation as a complication for an MRI scan. The patient had a tight bandage around the head to hold the magnet in place as recommended by the manufacturer, but apparently the bandage was not in the correct place.

  13. The experimental study of radiation injury on bile duct and liver tissue

    International Nuclear Information System (INIS)

    Cao Guiwen; Wang Bin; Sun Yequan; Shao Xueye; Ning Houfa; Sui Shouguang; Wang Xiuchun; Bai Xuming

    2007-01-01

    Objective: To investigate the safety, acceptance and the effective extent of 192 Ir-internal irradiation, providing theoretical guidelines for HC. Methods: Sixteen male healthy hybrid dogs enrolled in the experiment were divided into 4 groups of 4 each. The brachytherapy applicator was introduced from gall bladder into the convergence of cystic duct with common hepatic duct during the operation and a small chip of 1 cm 3 liver tissue was cut off and taken for control later on. The animals in group A-D were irradiated by 192 Ir-internal irradiation with 30 Gy, 40 Gy, 50 Gy arid 60 Gy at the correlative dose points respectively. Animals were put to death after 10 days subsequently, with sampling specimens obtained from radiation cystic duct and the in between liver tissue with the distant cystic duct. The radiation injury of the cystic duct and liver tissue near bile ducts were observed and studied by light microscope and transmission election microscope. Results: By the limit of the safest endurance dose(50 Gy) of Bile duct, unreversed injury of the nuclei of liver cells occurred at 0 to 15 mm from bile duct revealed by transmission electron microscope and light microscope. The whole biliary duct wall would be undergone necrosis with irradiation dose over 60 Gy. Conclusions: Normal bile duct possesses good endurance to 192 Ir-internal irradiation. Within the safest endurance limit of 50 Gy the effective irradiation field could reach 15 mm from the involved bile duct. (authors)

  14. Cochlear implant benefits in deafness rehabilitation: PET study of temporal voice Activations

    Energy Technology Data Exchange (ETDEWEB)

    Coez, A.; Zilbovicius, M. [CEA, Serv Hosp Frederic Joliot, INSERM, Res Unit Neuroimaging and Psychiat, U797, IFR49, F-91406 Orsay (France); Zilbovicius, M.; Syrota, A.; Samson, Y. [CEA, DSV, DRM, Serv Hosp Frederic Joliot, F-91406 Orsay (France); Bizaguet, E. [Lab Correct Audit, Paris (France); Coez, A. [Univ Paris Sud 11, Paris (France); Ferrary, E.; Bouccara, D.; Mosnier, I.; Sterkers, O. [INSERM, Unit M 867, Paris (France); Ambert-Dahan, E. [Hop Beaujon, Serv ORL Chirurg Cervicofaciale, AP-HP, Clichy (France); Ferrary, E.; Bouccara, D.; Mosnier, I.; Sterkers, O. [Inst Fed Rech Claude Bernard Physiol et Pathol, IFR02, Paris (France); Samson, Y. [Hop La Pitie Salpetriere, Serv Urgences Cerebro-vasc, AP-HP, Paris (France); Samson, Y. [Univ Paris 06, Paris (France); Sterkers, O. [Univ Denis Diderot Paris 7, Paris (France)

    2008-07-01

    Cochlear implants may improve the medical and social prognosis of profound deafness. Nevertheless, some patients have experienced poor results without any clear explanations. One correlate may be an alteration in cortical voice processing. To test this hypothesis, we studied the activation of human temporal voice areas (TVA) using a well-standardized PET paradigm adapted from previous functional MRI (fMRI) studies. Methods: A PET H{sub 2}{sup 15}O activation study was performed on 3 groups of adult volunteers: normal-hearing control subjects (n 6) and cochlear-implanted post-lingually deaf patients with {>=}2 y of cochlear implant experience, with intelligibility scores in the 'Lafon monosyllabic task' {>=}80% (Good group; n 6) or {<=}20% (Poor group; n 6). Relative cerebral blood flow was measured in 3 conditions: rest, passive listening to human voice, and non-voice stimuli. Results: Compared with silence, the activations induced by non-voice stimuli were bilaterally located in the superior temporal regions in all groups. However these activations were significantly and similarly reduced in both cochlear implant groups, whereas control subjects showed supplementary activations. Compared with non-voice, the voice stimuli induced bilateral activation of the TVA along the superior temporal sulcus (STS) in both the control and the Good groups. In contrast, these activations were not detected in the Poor group, which showed only left unilateral middle STS activation. Conclusion: These results suggest that PET is an adequate method to explore cochlear implant benefits and that this benefit could be linked to the activation of the TVA. (authors)

  15. Cochlear implant benefits in deafness rehabilitation: PET study of temporal voice Activations

    International Nuclear Information System (INIS)

    Coez, A.; Zilbovicius, M.; Zilbovicius, M.; Syrota, A.; Samson, Y.; Bizaguet, E.; Coez, A.; Ferrary, E.; Bouccara, D.; Mosnier, I.; Sterkers, O.; Ambert-Dahan, E.; Ferrary, E.; Bouccara, D.; Mosnier, I.; Sterkers, O.; Samson, Y.; Samson, Y.; Sterkers, O.

    2008-01-01

    Cochlear implants may improve the medical and social prognosis of profound deafness. Nevertheless, some patients have experienced poor results without any clear explanations. One correlate may be an alteration in cortical voice processing. To test this hypothesis, we studied the activation of human temporal voice areas (TVA) using a well-standardized PET paradigm adapted from previous functional MRI (fMRI) studies. Methods: A PET H 2 15 O activation study was performed on 3 groups of adult volunteers: normal-hearing control subjects (n 6) and cochlear-implanted post-lingually deaf patients with ≥2 y of cochlear implant experience, with intelligibility scores in the 'Lafon monosyllabic task' ≥80% (Good group; n 6) or ≤20% (Poor group; n 6). Relative cerebral blood flow was measured in 3 conditions: rest, passive listening to human voice, and non-voice stimuli. Results: Compared with silence, the activations induced by non-voice stimuli were bilaterally located in the superior temporal regions in all groups. However these activations were significantly and similarly reduced in both cochlear implant groups, whereas control subjects showed supplementary activations. Compared with non-voice, the voice stimuli induced bilateral activation of the TVA along the superior temporal sulcus (STS) in both the control and the Good groups. In contrast, these activations were not detected in the Poor group, which showed only left unilateral middle STS activation. Conclusion: These results suggest that PET is an adequate method to explore cochlear implant benefits and that this benefit could be linked to the activation of the TVA. (authors)

  16. Iatrogenic injury of an aberrant right posterior sectoral bile duct

    African Journals Online (AJOL)

    (Figs 1 and 2). A week later, an endoscopic retrograde cholangiopancreatography. (ERCP) examination was performed. This showed no filling of the right posterior sectoral ducts but normal opacification of the other ducts. (Figs 3a and b). These findings led to the diagnosis of an aberrant right posterior sectoral bile duct that ...

  17. Cochlear function tests in estimation of speech dynamic range.

    Science.gov (United States)

    Han, Jung Ju; Park, So Young; Park, Shi Nae; Na, Mi Sun; Lee, Philip; Han, Jae Sang

    2016-10-01

    The loss of active cochlear mechanics causes elevated thresholds, loudness recruitment, and reduced frequency selectivity. The problems faced by hearing-impaired listeners are largely related with reduced dynamic range (DR). The aim of this study was to determine which index of the cochlear function tests correlates best with the DR to speech stimuli. Audiological data on 516 ears with pure tone average (PTA) of ≤55 dB and word recognition score of ≥70% were analyzed. PTA, speech recognition threshold (SRT), uncomfortable loudness (UCL), and distortion product otoacoustic emission (DPOAE) were explored as the indices of cochlear function. Audiometric configurations were classified. Correlation between each index and the DR was assessed and multiple regression analysis was done. PTA and SRT demonstrated strong negative correlations with the DR (r = -0.788 and -0.860, respectively), while DPOAE sum was moderately correlated (r = 0.587). UCLs remained quite constant for the total range of the DR. The regression equation was Y (DR) = 75.238 - 0.719 × SRT (R(2 )=( )0.721, p equation.

  18. Imaging features of intraductal papillary neoplasm of the bile duct

    International Nuclear Information System (INIS)

    Liu Yubao; Li Meng; Zhong Xiaomei; Liu Zaiyi; Liang Changhong

    2014-01-01

    Objective: To investigate the CT and MRI features of intraductal papillary neoplasm of the bile duct (IPNB). Methods: Thirty eight patients with IPNB finally diagnosed by puncture biopsy or surgery were enrolled in this study. All the CT or MRI data were investigated retrospectively. Twenty one patients underwent CT examinations, 17 patients underwent MRI examinations. The features of IPNB including the distribution features of the nodules or masses, CT and MRI features of cholangiectasis, mucus were analyzed. The accuracy differences of CT and MRI for the preoperatively diagnosing mucus and tumor growing along mucous were compared by nonparametric test. Results: The lesions (including 5 patients with solitary lesions and 19 patients with multiple lesions) were located in intrahepatic bile duct in 24 patients, 3 patients occurred simultaneously in intrahepatic and portal bile duct, 2 lesions occurred in portal bile duct, 8 lesions occurred in common bile duct, the lesions of 1 patient occurred simultaneously in common bile duct, cystic duct and gallbladder. Seventeen and 11 patients appeared nodules locating in dilated bile duct on CT and MRI, respectively. Four and 5 patients appeared cystic lesions with multiple nodules of the liver on CT and MRI, respectively. Higher contrast enhancement on CT and MRI in arterial phase than that in portal vein and equilibrium phase were observed in 18 and 12 patients, respectively. Excluding the patients undergoing puncture, CT was better than MRI in evaluating whether the mucus was present, with the accuracies of 30.0% (6/20) and 6.3% (1/16) for CT and MRI, respectively (Z=2.58, P<0.05). CT was worse than MRI in preoperatively evaluating the features of tumor growing along mucous, with the accuracies of 77.8% (14/18) and 92.6% (13/14) for CT and MRI, respectively (Z=4.23, P<0.01). Conclusion: IPNB had the features of growing along mucous of the bile duct, nodule or mass in dilated bile duct and other features, CT and MRI are

  19. Ursodeoxycholic acid treatment of vanishing bile duct syndromes

    NARCIS (Netherlands)

    Pusl, Thomas; Beuers, Ulrich

    2006-01-01

    Vanishing bile duct syndromes (VBDS) are characterized by progressive loss of small intrahepatic ducts caused by a variety of different diseases leading to chronic cholestasis, cirrhosis, and premature death from liver failure. The majority of adult patients with VBDS suffer from primary biliary

  20. Positive predictive value of cholescintigraphy in common bile duct obstruction

    International Nuclear Information System (INIS)

    Lecklitner, M.L.; Austin, A.R.; Benedetto, A.R.; Growcock, G.W.

    1986-01-01

    Technetium-99m DISIDA imaging was employed in 400 patients to differentiate obstruction of the common bile duct from medical and other surgical causes of hyperbilirubinemia. Sequential anterior images demonstrated variable degrees of liver uptake, yet there was no evidence of intrabiliary or extrabiliary radioactivity for at least 4 hr after injection in 25 patients. Twenty-three patients were surgically documented to have complete obstruction of the common bile duct. One patient had hepatitis, and another had sickle cell crisis without bile duct obstruction. The remaining patients had either partial or no obstruction of the common bile duct. We conclude that the presence of liver uptake without evident biliary excretion by 4 hr on cholescintigraphy is highly sensitive and predictive of total obstruction of the common bile duct

  1. Electroacoustic verification of frequency modulation systems in cochlear implant users.

    Science.gov (United States)

    Fidêncio, Vanessa Luisa Destro; Jacob, Regina Tangerino de Souza; Tanamati, Liége Franzini; Bucuvic, Érika Cristina; Moret, Adriane Lima Mortari

    2017-12-26

    The frequency modulation system is a device that helps to improve speech perception in noise and is considered the most beneficial approach to improve speech recognition in noise in cochlear implant users. According to guidelines, there is a need to perform a check before fitting the frequency modulation system. Although there are recommendations regarding the behavioral tests that should be performed at the fitting of the frequency modulation system to cochlear implant users, there are no published recommendations regarding the electroacoustic test that should be performed. Perform and determine the validity of an electroacoustic verification test for frequency modulation systems coupled to different cochlear implant speech processors. The sample included 40 participants between 5 and 18 year's users of four different models of speech processors. For the electroacoustic evaluation, we used the Audioscan Verifit device with the HA-1 coupler and the listening check devices corresponding to each speech processor model. In cases where the transparency was not achieved, a modification was made in the frequency modulation gain adjustment and we used the Brazilian version of the "Phrases in Noise Test" to evaluate the speech perception in competitive noise. It was observed that there was transparency between the frequency modulation system and the cochlear implant in 85% of the participants evaluated. After adjusting the gain of the frequency modulation receiver in the other participants, the devices showed transparency when the electroacoustic verification test was repeated. It was also observed that patients demonstrated better performance in speech perception in noise after a new adjustment, that is, in these cases; the electroacoustic transparency caused behavioral transparency. The electroacoustic evaluation protocol suggested was effective in evaluation of transparency between the frequency modulation system and the cochlear implant. Performing the adjustment of

  2. A case of improved hearing with cochlear implantation in Gaucher disease type 1.

    Science.gov (United States)

    Endo, Shiori; Mizuta, Kunihiro; Yamatodani, Takashi; Nakanishi, Hiroshi; Hosokawa, Kumiko; Misawa, Kiyoshi; Hosokawa, Seiji; Mineta, Hiroyuki

    2018-06-01

    Gaucher disease is a lysosomal storage disorder that is caused by congenital defective function of the enzyme glucocerebrosidase. Glucocerebroside that is not hydrolyzed by glucocerebrosidase mainly accumulates in the reticular tissue. We describe a Japanese boy with Gaucher disease type 1 who developed bilateral profound sensorineural hearing loss within approximately 4years. We performed cochlear implantation initially on his right ear and again on his left ear 5 months later. The cochlear implants were successfully utilized with a speech discrimination score of 95% on a Japanese sentence recognition test. There are many reports of central hearing loss in Gaucher disease type 2 or 3. However, to the best of our knowledge, this is the first report of profound inner ear hearing loss with Gaucher disease. It also appears to be the first record of cochlear implantation for Gaucher disease. Cochlear implants may be useful for sensorineural hearing loss in patients with Gaucher disease without neurological symptoms other than hearing loss. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Electrode selection for hearing preservation in cochlear implantation: A review of the evidence

    Directory of Open Access Journals (Sweden)

    Jason A. Brant

    2016-09-01

    Full Text Available Objective: To review and assess the ideal length of electrode in cochlear implant patients for hearing preservation. Methods: The English language literature was reviewed for studies including hearing preservation and speech understanding for electrodes of different lengths. Results: One prospective trial was found, and there were no studies that randomized patients into different length electrodes with an intent to preserve hearing. Eight studies total included multiple length electrodes and contained data regarding hearing preservation. Conclusions: Although there is some evidence that indicates that shorter electrodes may improve both short and long-term hearing preservation rates in cochlear implant patients, no study has directly compared implant length on hearing preservation in a similar patient population. A randomized trial of short and standard length electrodes for hearing preservation is warranted. In the interim, utilization of current electrodes measuring 20–25 mm could seem to be a prudent approach when seeking to preserve residual hearing without unduly compromising cochlear coverage. Keywords: Electrode, Length, Hearing preservation, Cochlear implantation

  4. EEG frontal asymmetry related to pleasantness of music perception in healthy children and cochlear implanted users.

    Science.gov (United States)

    Vecchiato, G; Maglione, A G; Scorpecci, A; Malerba, P; Marsella, P; Di Francesco, G; Vitiello, S; Colosimo, A; Babiloni, Fabio

    2012-01-01

    Interestingly, the international debate about the quality of music fruition for cochlear implanted users does not take into account the hypothesis that bilateral users could perceive music in a more pleasant way with respect to monolateral users. In this scenario, the aim of the present study was to investigate if cerebral signs of pleasantness during music perception in healthy child are similar to those observed in monolateral and in bilateral cochlear implanted users. In fact, previous observations in literature on healthy subjects have indicated that variations of the frontal EEG alpha activity are correlated with the perceived pleasantness of the sensory stimulation received (approach-withdrawal theory). In particular, here we described differences between cortical activities estimated in the alpha frequency band for a healthy child and in patients having a monolateral or a bilateral cochlear implant during the fruition of a musical cartoon. The results of the present analysis showed that the alpha EEG asymmetry patterns observed in a healthy child and that of a bilateral cochlear implanted patient are congruent with the approach-withdrawal theory. Conversely, the scalp topographic distribution of EEG power spectra in the alpha band resulting from the monolateral cochlear user presents a different EEG pattern from the normal and bilateral implanted patients. Such differences could be explained at the light of the approach-withdrawal theory. In fact, the present findings support the hypothesis that a monolateral cochlear implanted user could perceive the music in a less pleasant way when compared to a healthy subject or to a bilateral cochlear user.

  5. Degradation of labial information modifies audiovisual speech perception in cochlear-implanted children.

    Science.gov (United States)

    Huyse, Aurélie; Berthommier, Frédéric; Leybaert, Jacqueline

    2013-01-01

    The aim of the present study was to examine audiovisual speech integration in cochlear-implanted children and in normally hearing children exposed to degraded auditory stimuli. Previous studies have shown that speech perception in cochlear-implanted users is biased toward the visual modality when audition and vision provide conflicting information. Our main question was whether an experimentally designed degradation of the visual speech cue would increase the importance of audition in the response pattern. The impact of auditory proficiency was also investigated. A group of 31 children with cochlear implants and a group of 31 normally hearing children matched for chronological age were recruited. All children with cochlear implants had profound congenital deafness and had used their implants for at least 2 years. Participants had to perform an /aCa/ consonant-identification task in which stimuli were presented randomly in three conditions: auditory only, visual only, and audiovisual (congruent and incongruent McGurk stimuli). In half of the experiment, the visual speech cue was normal; in the other half (visual reduction) a degraded visual signal was presented, aimed at preventing lipreading of good quality. The normally hearing children received a spectrally reduced speech signal (simulating the input delivered by the cochlear implant). First, performance in visual-only and in congruent audiovisual modalities were decreased, showing that the visual reduction technique used here was efficient at degrading lipreading. Second, in the incongruent audiovisual trials, visual reduction led to a major increase in the number of auditory based responses in both groups. Differences between proficient and nonproficient children were found in both groups, with nonproficient children's responses being more visual and less auditory than those of proficient children. Further analysis revealed that differences between visually clear and visually reduced conditions and between

  6. Common Bile Duct Perforation Due to Tuberculosis: A Case Report

    OpenAIRE

    Razman Jarmin; Shaharin Shaharuddin

    2004-01-01

    A young man with HIV presented with biliary peritonitis secondary to spontaneous common bile duct perforation. Investigation revealed that the perforation was due to Mycobacterium tuberculosis. Tuberculosis of the bile duct is uncommon and usually presents with obstructive jaundice due to stricture. Bile duct perforation due to tuberculosis is extremely rare. Its management is discussed.

  7. Trypsin level in gallbladder bile and ductitis and width of the cystic duct.

    Science.gov (United States)

    Vracko, J; Wiechel, K L

    2000-01-01

    The change from laparotomy to laparoscopy for cholecystectomy has raised the question of how to manage concomitant bile duct stones. The present-day interest--and controversy--has focused on a transcystic approach reported to be feasible in 66-96% of cases, but without explaining the necessary prerequisite: the widening of the cystic duct. The cystic duct, wide mainly in patients with bile duct stones, has been reported to be highly variable: from strictured to very wide. The present study aims at comparing the trypsin level in the gallbladder bile and the cystic duct morphology and width in patients with and without bile duct stones. A prospective series of 63 gallstone patients, 30 with and 33 without bile duct stones (controls), underwent cholecystectomy and bile duct clearance. The study includes the trypsin level in the gallbladder bile, the width and morphology of the cystic duct, and the size of the gallstones. The patients with bile duct stones had, in contrast to the controls, higher trypsin levels in the gallbladder bile (P extraction feasible.

  8. Routes, dynamics, and correlates of cochlear inflammation in terminal and recovering experimental meningitis

    DEFF Research Database (Denmark)

    Cayé-Thomasen, Per; Worsøe, Lise; Brandt, Christian Thomas

    2009-01-01

    OBJECTIVES/HYPOTHESIS: To examine the routes, dynamics and correlates of cochlear inflammation in meningitis to provide information on the pathogenesis of the associated hearing loss and indications for rational pharmacotherapeutical intervention. STUDY DESIGN: A well-established rat model...... with inflammatory cells via cochlear aqueduct, whereas the endolymphatic space was infiltrated from the spiral ligament. Rosenthal's canal was infiltrated through osseous spiral lamina canaliculi. In the untreated group, the degree of inflammation correlated with time of death, whereas antibiotic treatment reversed...... this development. Perilymphatic inflammation correlated significantly with the CSF leukocyte count, whereas endolymphatic inflammation correlated with spiral ligament inflammation. CONCLUSIONS: Meningogenic inflammation of the rat cochlea occurs via the cochlear aqueduct and the spiral ligament capillary bed...

  9. Thermal performance test of the hot gas ducts of HENDEL

    International Nuclear Information System (INIS)

    Hishida, M.; Kunitomi, K.; Ioka, I.; Umenishi, K.; Tanaka, T.; Shimomura, H.; Sanokawa, K.

    1984-01-01

    A hot gas duct provided with internal thermal insulation is to be used for high-temperature gas-cooled reactors (HTGR). This type of hot gas duct has not been used so far in industrial facilities, and only a couple of tests on such a large-scale model of a hot gas duct have been conducted. The present report deals with the results of the thermal performance of the single tube type hot gas ducts which are installed as parts of a helium engineering demonstration loop (HENDEL). Uniform temperature and heat flux distribution at the surface of the duct were observed, the experimental correlations being obtained for the effective thermal conductivity of the internal thermal insulation layer. The measured temperature distribution of the pressure tube was in good agreement with the calculation by a TRUMP heat transfer computer code. The temperature distribution of the inner tube of the co-axial hot gas duct was evaluated and no hot spot was detected. These results would be very valuable for the design and development of HTGR. (orig.)

  10. Predicting social functioning in children with a cochlear implant and in normal-hearing children: the role of emotion regulation.

    Science.gov (United States)

    Wiefferink, Carin H; Rieffe, Carolien; Ketelaar, Lizet; Frijns, Johan H M

    2012-06-01

    The purpose of the present study was to compare children with a cochlear implant and normal hearing children on aspects of emotion regulation (emotion expression and coping strategies) and social functioning (social competence and externalizing behaviors) and the relation between emotion regulation and social functioning. Participants were 69 children with cochlear implants (CI children) and 67 normal hearing children (NH children) aged 1.5-5 years. Parents answered questionnaires about their children's language skills, social functioning, and emotion regulation. Children also completed simple tasks to measure their emotion regulation abilities. Cochlear implant children had fewer adequate emotion regulation strategies and were less socially competent than normal hearing children. The parents of cochlear implant children did not report fewer externalizing behaviors than those of normal hearing children. While social competence in normal hearing children was strongly related to emotion regulation, cochlear implant children regulated their emotions in ways that were unrelated with social competence. On the other hand, emotion regulation explained externalizing behaviors better in cochlear implant children than in normal hearing children. While better language skills were related to higher social competence in both groups, they were related to fewer externalizing behaviors only in cochlear implant children. Our results indicate that cochlear implant children have less adequate emotion-regulation strategies and less social competence than normal hearing children. Since they received their implants relatively recently, they might eventually catch up with their hearing peers. Longitudinal studies should further explore the development of emotion regulation and social functioning in cochlear implant children. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  11. Agenesis of the gallbladder with hypoplastic cystic duct diagnosed at laparoscopy.

    Science.gov (United States)

    Kwon, A-Hon; Yanagimoto, Hiroaki; Matsui, Yoichi; Imamura, Atsushi

    2006-08-01

    An 86-year-old man was admitted to our department with complaints of intermittent upper abdominal pain. Ultrasonography of the abdomen showed dilated extrahepatic bile ducts containing stones; however, the gallbladder was not clearly identified. Magnetic resonance cholangiopancreatography showed dilated extrahepatic ducts and choledocholithiasis without gallbladder visualization. The stone extraction was performed with endoscopic sphincterotomy. Three-dimensional images using spiral-computed tomography after intravenous-infusion cholangiography clearly demonstrated an obstruction of the cystic duct. The patient was scheduled for laparoscopic cholecystectomy. At laparoscopy, the gallbladder fossa was not identified on the undersurface of the liver. Despite a thorough examination of the intrahepatic (left-sided within the lesser omentum), retroperitoneal, retrohepatic (within the falciform ligament), retroduodenal, and retropancreatic areas using laparoscopic ultrasonography, the gallbladder was not found. After careful dissection of the hepatoduodenal ligament, the dilated extrahepatic bile duct and a 1-cm length of hypoplastic cystic duct were found. Gallbladder agenesis is usually accompanied by the lack of the cystic duct. The present case is the third report of gallbladder agenesis with a patent or hypoplastic cystic duct.

  12. Cystic duct closure by sealing with bipolar electrocoagulation

    DEFF Research Database (Denmark)

    Schulze, S; Damgaard, B; Jørgensen, Lars Nannestad

    2010-01-01

    BACKGROUND: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure) for closure of the cystic duct. METHODS: The records from consecutive laparoscopic cholecystectomies performed i...

  13. Common Bile Duct Perforation Due to Tuberculosis: A Case Report

    Directory of Open Access Journals (Sweden)

    Razman Jarmin

    2004-10-01

    Full Text Available A young man with HIV presented with biliary peritonitis secondary to spontaneous common bile duct perforation. Investigation revealed that the perforation was due to Mycobacterium tuberculosis. Tuberculosis of the bile duct is uncommon and usually presents with obstructive jaundice due to stricture. Bile duct perforation due to tuberculosis is extremely rare. Its management is discussed.

  14. Measured Performance of a Varied Airflow Small-Diameter Duct System

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-03-01

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

  15. Measured Performance of a Varied Airflow Small-Diameter Duct System

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-03-16

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

  16. Electrophysiological evidence for altered visual, but not auditory, selective attention in adolescent cochlear implant users.

    Science.gov (United States)

    Harris, Jill; Kamke, Marc R

    2014-11-01

    Selective attention fundamentally alters sensory perception, but little is known about the functioning of attention in individuals who use a cochlear implant. This study aimed to investigate visual and auditory attention in adolescent cochlear implant users. Event related potentials were used to investigate the influence of attention on visual and auditory evoked potentials in six cochlear implant users and age-matched normally-hearing children. Participants were presented with streams of alternating visual and auditory stimuli in an oddball paradigm: each modality contained frequently presented 'standard' and infrequent 'deviant' stimuli. Across different blocks attention was directed to either the visual or auditory modality. For the visual stimuli attention boosted the early N1 potential, but this effect was larger for cochlear implant users. Attention was also associated with a later P3 component for the visual deviant stimulus, but there was no difference between groups in the later attention effects. For the auditory stimuli, attention was associated with a decrease in N1 latency as well as a robust P3 for the deviant tone. Importantly, there was no difference between groups in these auditory attention effects. The results suggest that basic mechanisms of auditory attention are largely normal in children who are proficient cochlear implant users, but that visual attention may be altered. Ultimately, a better understanding of how selective attention influences sensory perception in cochlear implant users will be important for optimising habilitation strategies. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. Extracorporeal shock-wave lithotripsy of bile duct stones

    International Nuclear Information System (INIS)

    Lee, Jong Tae; Kim, Myung Joon; Yoo, Hyung Sik; Suh, Jung Ho; Lee, Moo Sang; Jo, Jang Hwan; Kim, Byung Ro

    1989-01-01

    During the past one and half year, we performed ESWL therapy in 13 patients with common bile duct and intrahepatic duct stones, applying Lithostar-R (Siemens co. West Germany) and analyzed their results. In 13 patients, 9 residual common bile duct stones and 7 intrahepatic duct stones were selected postoperatively. The size of stones were ranged from 0.7 cm to 3.5 cm in diameter. 2 stones were multiple and the remained 14 were single in number. The visualization of stones were done with fluoroscopy after the injection of contrast media via cholangiographic T-tube or ERCP. ESWL were applied continuously until stone disintegration was visible, or upto maximum number of 3500 discharge of shock wave. If not disintegrated upto 3500, patients were underwent second or third lithotripsy session with interval of one week. Our results showed that among 9 common bile duct stones, 4 were completely disintegrated and passed out spontaneously, but 3 partially fragmented and removed by the additional procedure. 2 were failed. Among 7 intrahepatic stones, 3 completely and 2 partially were succeeded. One stone partially fragmented were retained without removal and other one were failed. Skin petechia in all patients were revealed on the entry port of shock wave, but no serous complication was not occurred

  18. Extracorporeal shock-wave lithotripsy of bile duct stones

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Tae; Kim, Myung Joon; Yoo, Hyung Sik; Suh, Jung Ho; Lee, Moo Sang; Jo, Jang Hwan; Kim, Byung Ro [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1989-12-15

    During the past one and half year, we performed ESWL therapy in 13 patients with common bile duct and intrahepatic duct stones, applying Lithostar-R (Siemens co. West Germany) and analyzed their results. In 13 patients, 9 residual common bile duct stones and 7 intrahepatic duct stones were selected postoperatively. The size of stones were ranged from 0.7 cm to 3.5 cm in diameter. 2 stones were multiple and the remained 14 were single in number. The visualization of stones were done with fluoroscopy after the injection of contrast media via cholangiographic T-tube or ERCP. ESWL were applied continuously until stone disintegration was visible, or upto maximum number of 3500 discharge of shock wave. If not disintegrated upto 3500, patients were underwent second or third lithotripsy session with interval of one week. Our results showed that among 9 common bile duct stones, 4 were completely disintegrated and passed out spontaneously, but 3 partially fragmented and removed by the additional procedure. 2 were failed. Among 7 intrahepatic stones, 3 completely and 2 partially were succeeded. One stone partially fragmented were retained without removal and other one were failed. Skin petechia in all patients were revealed on the entry port of shock wave, but no serous complication was not occurred.

  19. Cochlear neuropathy in human presbycusis: Confocal analysis of hidden hearing loss in post-mortem tissue.

    Science.gov (United States)

    Viana, Lucas M; O'Malley, Jennifer T; Burgess, Barbara J; Jones, Dianne D; Oliveira, Carlos A C P; Santos, Felipe; Merchant, Saumil N; Liberman, Leslie D; Liberman, M Charles

    2015-09-01

    Recent animal work has suggested that cochlear synapses are more vulnerable than hair cells in both noise-induced and age-related hearing loss. This synaptopathy is invisible in conventional histopathological analysis, because cochlear nerve cell bodies in the spiral ganglion survive for years, and synaptic analysis requires special immunostaining or serial-section electron microscopy. Here, we show that the same quadruple-immunostaining protocols that allow synaptic counts, hair cell counts, neuronal counts and differentiation of afferent and efferent fibers in mouse can be applied to human temporal bones, when harvested within 9 h post-mortem and prepared as dissected whole mounts of the sensory epithelium and osseous spiral lamina. Quantitative analysis of five "normal" ears, aged 54-89 yrs, without any history of otologic disease, suggests that cochlear synaptopathy and the degeneration of cochlear nerve peripheral axons, despite a near-normal hair cell population, may be an important component of human presbycusis. Although primary cochlear nerve degeneration is not expected to affect audiometric thresholds, it may be key to problems with hearing in noise that are characteristic of declining hearing abilities in the aging ear. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Ethical considerations in resource allocation in a cochlear implant program.

    Science.gov (United States)

    Westerberg, Brian D; Pijl, Sipke; McDonald, Michael

    2008-04-01

    To review processes of resource allocation and the ethical considerations relevant to the fair allocation of a limited number of cochlear implants to increasing numbers of potential recipients. Review of relevant considerations. Tertiary referral hospital. Editorial discussion of the ethical issues of resource allocation. Heterogeneity of audiometric thresholds, self-reported disability of hearing loss, age of the potential cochlear implant recipient, cost-effectiveness, access to resources, compliance with follow-up, social support available to the recipient, social consequences of hearing impairment, and other recipient-related factors. In a publicly funded health care system, there will always be a need for decision-making processes for allocation of finite fiscal resources. All candidates for cochlear implantation deserve fair consideration. However, they are a heterogeneous group in terms of needs and expected outcomes consisting of traditional and marginal candidates, with a wide range of benefit from acoustic amplification. We argue that implant programs should thoughtfully prioritize treatment on the basis of need and potential benefit. We reject queuing on the basis of "first-come, first-served" or on the basis of perceived social worth.

  1. ATP release, generation and hydrolysis in exocrine pancreatic duct cells

    DEFF Research Database (Denmark)

    Kowal, Justyna Magdalena; Yegutkin, G.G.; Novak, Ivana

    2015-01-01

    Extracellular adenosine triphosphate (ATP) regulates pancreatic duct function via P2Y and P2X receptors. It is well known that ATP is released from upstream pancreatic acinar cells. The ATP homeostasis in pancreatic ducts, which secrete bicarbonate-rich fluid, has not yet been examined. First, ou...... may be important in pancreas physiology and potentially in pancreas pathophysiology....... aim was to reveal whether pancreatic duct cells release ATP locally and whether they enzymatically modify extracellular nucleotides/sides. Second, we wished to explore which physiological and pathophysiological factors may be important in these processes. Using a human pancreatic duct cell line, Capan...

  2. Computed tomography of hepatocellular carcinoma. Dilatation of intrahepatic bile duct

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Soomi; Nakamura, Hitonobu; Tanaka, Ken; Hori, Shinichi; Tokunaga, Kou [Osaka Univ. (Japan). Faculty of Medicine

    1983-10-01

    Based on a series of CT of the liver in 125 patients with hepatoma and 45 patients with metastatic hepatic tumors, the mode of dilatation of the intrahepatic bile duct was examined. In patients with hepatoma, partia dilatations of intrahepatic bile duct were more commonly seen than general dilatations. On the other hand, there was no case of partial dilatation of the intrahepatic bile duct in patients with metastatic hepatic tumors. It could be concluded that partial dilatation of the intrahepatic bile duct is an useful CT finding to make a diagnosis of hepatoma, particularly to differentiate hepatoma from metastatic hepatic tumor.

  3. Standardization of reliability reporting for cochlear implants: an interim report.

    Science.gov (United States)

    Backous, Douglas D; Watson, Stacey D

    2007-04-01

    To propose a standard definition of "out of specification" for cochlear implants and a paradigm for inclusion of category C of the ISO standard 5841-2:2000 for reporting in cumulative survival statistics. A standard definition of "out of specification" and consistent reporting by manufacturers of cochlear implants will create a fair and consistent representation of cumulative survival. This will allow discernment of differences between manufacturers for reliability and for detection of trends in reliability between model types from the same manufacturer. Three separate meetings with representatives of the three manufacturers of cochlear implants marketed in the United States were staged over a 13-mo period. Standard questions, created by the authors, were addressed by each representative to determine the current state of device reliability reporting. Results were presented to clinicians at the William House Cochlear Implant study Group and the Implantable devices sub-committee of the American Academy of Otolaryngology (2004, 2005) and at the 8th International Cochlear Implant Conference (2004) for feedback. After assimilation of feedback by all parties, the standard was written and reviewed by representatives from each manufacturer for accuracy of data. A complaint-driven standard was developed. A "cochlear implant" as an internal device placed and skin closed in surgery. An internal device is "out of specification" when one or more technical characteristics is outside the limits of normal function and results in explantation or non-use by the patient." Children will be reported separately from adults, each model of device will be reported on annually, a minimum of 200 devices must be in each model group for Cumulative Survival Reporting (CSR). Confidence limits are set at 95%. Explants will be determined to be "biological" or "technical." Technical explants are included in CSR reports. Devices failing to meet specifications set by the manufacturer, not in use but

  4. Wired to freedom: Life science, public politics, and the case of Cochlear Implantation.

    Science.gov (United States)

    Jepsen, Kim Sune; Bertilsson, T Margareta

    2017-02-01

    Cochlear Implantation is now regarded as the most successful medical technology. It carries promises to provide deaf/hearing impaired individuals with a technological sense of hearing and an access to participate on a more equal level in social life. In this article, we explore the adoption of cochlear implantations among Danish users in order to shed more light on their social and political implications. We situate cochlear implantation in a framework of new life science advances, politics, and user experiences. Analytically, we draw upon the notion of social imaginary and explore the social dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being "wired to freedom" that involves new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as "wired to freedom," we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear Implantation. As our empirical observations are largely based in the Scandinavian countries (notably Denmark), we also provide some reflections on the character of the technology-friendly Scandinavian welfare states and the unintended consequences that may follow in the wake of rapid technology implementation of life science in society.

  5. Speech recognition and communication outcomes with cochlear implantation in Usher syndrome type 3.

    Science.gov (United States)

    Pietola, Laura; Aarnisalo, Antti A; Abdel-Rahman, Akram; Västinsalo, Hanna; Isosomppi, Juha; Löppönen, Heikki; Kentala, Erna; Johansson, Reijo; Valtonen, Hannu; Vasama, Juha-Pekka; Sankila, Eeva-Marja; Jero, Jussi

    2012-01-01

    Usher syndrome Type 3 (USH3) is an autosomal recessive disorder characterized by variable type and degree of progressive sensorineural hearing loss and retinitis pigmentosa. Cochlear implants are widely used among these patients. To evaluate the results and benefits of cochlear implantation in patients with USH3. A nationwide multicenter retrospective review. During the years 1995-2005, in 5 Finnish university hospitals, 19 patients with USH3 received a cochlear implant. Saliva samples were collected to verify the USH3 genotype. Patients answered to 3 questionnaires: Glasgow Benefit Inventory, Glasgow Health Status Inventory, and a self-made questionnaire. Audiological data were collected from patient records. All the patients with USH3 in the study were homozygous for the Finnish major mutation (p.Y176X). Either they had severe sensorineural hearing loss or they were profoundly deaf. The mean preoperative hearing level (pure-tone average, 0.5-4 kHz) was 110 ± 8 dB hearing loss (HL) and the mean aided hearing level was 58 ± 11 dB HL. The postoperative hearing level (34 ± 9 dB HL) and word recognition scores were significantly better than before surgery. According to the Glasgow Benefit Inventory scores and Glasgow Health Status Inventory data related to hearing, the cochlear implantation was beneficial to patients with USH3. Cochlear implantation is beneficial to patients with USH3, and patients learn to use the implant without assistance.

  6. Modifying cochlear implant design: advantages of placing a return electrode in the modiolus.

    Science.gov (United States)

    Ho, Steven Y; Wiet, Richard J; Richter, Claus-Peter

    2004-07-01

    A modiolar return electrode significantly increases the current flow across spiral ganglion cells into the modiolus, and may decrease the cochlear implant's power requirements. Ideal cochlear implants should maximize current flow into the modiolus to stimulate auditory neurons. Previous efforts to facilitate current flow through the modiolus included the fabrication and use of precurved electrodes designed to "hug" the modiolus and silastic positioners designed to place the electrodes closer to the modiolus. In contrast to earlier efforts, this study explores the effects of return electrode placement on current distributions in the modiolus. The effects of return electrode positioning on current flow in the modiolus were studied in a Plexiglas model of the cochlea. Results of model measurements were confirmed by measurements in the modiolus of human temporal bones. The return electrode was placed either within the modiolus, or remotely, outside the temporal bone, simulating contemporary cochlear implant configurations using monopolar stimulation. Cochlear model results clearly show that modiolar current amplitudes can be influenced significantly by the location of the return electrode, being larger when placed into the modiolus. Temporal bone data show similar findings. Voltages recorded in the modiolus are, on average, 2.8 times higher with the return electrode in the modiolus compared with return electrode locations outside the temporal bone. Placing a cochlear implant's return electrode in the modiolus should significantly reduce its power consumption. Reducing power requirements should lead to improved efficiency, safer long-term use, and longer device life.

  7. Sirt3 confers protection against acrolein-induced oxidative stress in cochlear nucleus neurons.

    Science.gov (United States)

    Qu, Juan; Wu, Yong-Xiang; Zhang, Ting; Qiu, Yang; Ding, Zhong-Jia; Zha, Ding-Jun

    2018-03-01

    Acrolein is a ubiquitous dietary and environmental pollutant, which can also be generated endogenously during cellular stress. However, the molecular mechanisms underlying acrolein-induced neurotoxicity, especially in ototoxicity conditions, have not been fully determined. In this study, we investigated the mechanisms on acrolein-induced toxicity in primary cultured cochlear nucleus neurons with focus on Sirt3, a mitochondrial deacetylase. We found that acrolein treatment induced neuronal injury and programmed cell death (PCD) in a dose dependent manner in cochlear nucleus neurons, which was accompanied by increased intracellular reactive oxygen species (ROS) generation and lipid peroxidation. Acrolein exposure also significantly reduced the mitochondrial membrane potential (MMP) levels, promoted cytochrome c release and decreased mitochondrial ATP production. In addition, increased ER tracker fluorescence and activation of ER stress factors were observed after acrolein treatment, and the ER stress inhibitors were shown to attenuate acrolein-induced toxicity in cochlear nucleus neurons. The results of western blot and RT-PCR showed that acrolein markedly decreased the expression of Sirt3 at both mRNA and protein levels, and reduced the activity of downstream mitochondrial enzymes. Furthermore, overexpression of Sirt3 by lentivirus transfection partially prevented acrolein-induced neuronal injury in cochlear nucleus neurons. These results demonstrated that acrolein induces mitochondrial dysfunction and ER stress in cochlear nucleus neurons, and Sirt3 acts as an endogenous protective factor in acrolein-induced ototoxicity. Copyright © 2017. Published by Elsevier Ltd.

  8. Development of micro-electromechanical system (MEMS) cochlear biomodel

    Energy Technology Data Exchange (ETDEWEB)

    Ngelayang, Thailis Bounya Anak; Latif, Rhonira [Faculty of Electronic and Computer Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka (Malaysia)

    2015-05-15

    Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. In this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane.

  9. Development of micro-electromechanical system (MEMS) cochlear biomodel

    International Nuclear Information System (INIS)

    Ngelayang, Thailis Bounya Anak; Latif, Rhonira

    2015-01-01

    Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. In this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane

  10. A Review of Double Common Bile Duct and Its Sequelae.

    Science.gov (United States)

    Kolli, Sindhura; Etienne, Denzil; Reddy, Madhavi; Shahzad, Ghulamullah

    2018-02-01

    A double or accessory common bile duct (ACBD) is a rare congenital anomaly. We report the case of a 60-year-old American Asian male, who was found to have a double or duplicated common bile duct after being admitted for evaluation of a pancreatic mass. A duplicated bile duct has the same mucosa histologically as a single bile duct. However, the opening of a duplicated bile duct lacks a sphincter allowing retrograde flow of gut contents which results in a higher probability of intraductal calculus formation. On rare occasions, it can predispose to liver abscesses, pancreatitis, pancreatic cancer, gallbladder cancer, gastric cancer, and ampullary cancer depending on the location of the opening of the ACBD. We present an integrative review of the limited cases of ACBD with correlation to the current case and discussion regarding the aspects of diagnosis and management.

  11. Flow in curved ducts of varying cross-section

    Science.gov (United States)

    Sotiropoulos, F.; Patel, V. C.

    1992-07-01

    Two numerical methods for solving the incompressible Navier-Stokes equations are compared with each other by applying them to calculate laminar and turbulent flows through curved ducts of regular cross-section. Detailed comparisons, between the computed solutions and experimental data, are carried out in order to validate the two methods and to identify their relative merits and disadvantages. Based on the conclusions of this comparative study a numerical method is developed for simulating viscous flows through curved ducts of varying cross-sections. The proposed method is capable of simulating the near-wall turbulence using fine computational meshes across the sublayer in conjunction with a two-layer k-epsilon model. Numerical solutions are obtained for: (1) a straight transition duct geometry, and (2) a hydroturbine draft-tube configuration at model scale Reynolds number for various inlet swirl intensities. The report also provides a detailed literature survey that summarizes all the experimental and computational work in the area of duct flows.

  12. Hepatocellular carcinoma localized in the bile duct lumen: two case report

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Kyeung Kug; Chang, Jay Chun [Yeungnam Univ. School of Medicine, Seoul (Korea, Republic of)

    1998-10-01

    Intrabile duct tumor growth of hepatocellular carcinoma is an uncommon manifestation, but intraluminal bile duct hepatocellular carcinoma without primary hepatic parenchymal lesions is extremely rare. To our knowledge, only a few case reports have been published. We encountered two cases of primary hepatocellular carcinoma arising in the bile duct;serum alpha-fetoprotein levels were within the normal limits. Both showed the following characteristic radiologic features: (1) Cholangiography revealed filling defects within the dilated bile duct; (2) two-phase abdominal CT showed enhancement during the arterial-dominant phase and washout during the tissue equilibrium phase, as in typical HCC; and (3) hepateic arteriography revealed hypervascular tumor staining. Surgery was performed and the resected specimen showed no detectable primary hepatic parenchymal mass;on the basis of the pathologic finding, intraluminal bile duct hepatocellular carcinoma was confirmed. We cautiously assume that this peculiar type of HCC may arise primarily from bile duct mucosa.=20.

  13. Clinical and cholangiographic evaluation of bile duct carcinoma

    International Nuclear Information System (INIS)

    Park, Yeon Won; Kim, So Seon; Kim, Ho Joon; Joh, Young Duk; Chun, Byung Hee

    1986-01-01

    40 cases of bile duct carcinoma gathered over a 6-year period at Kosin Medical College were reviewed and their clinical and cholangiographic findings were as follows: 1. There were 29 males and 11 females (the ratio of men to women, 2.6:1) ranging from 37 to 74 years of age. The majority (70% of cases) were in 4th and 5th decades. 2. Clinical symptoms and signs: jaundice in 95%, RUQ or epigastric pain in 75%, pruritus in 52.5%, dark urine in 35%, weight loss in 32.5%, fever and chills in 22.5%, clay colored stool in 12.5%, and palpable mass in 12.5%. 3. Lab. findings: elevated serum total bilirubin (above 20.0mg% in 45%, 10.0-19.9mg% in 22.5%, 5.0-9.9mg% in 20%, 1.3-4.9mg% in 5%), elevated alkaline phosphatase in 95%. Clonorchiasis were noted in 17.5%. 4. Histologic findings were adenocarcinoma in most cases. 5. The location of bile duct carcinoma were common hepatic duct in 35%, common bile duct in 32.5%, porta hepatic in 12.5%, junction with cystic duct in 10% and diffuse form in 10%. 6. In 33 cases, PTC or post-operative cholangiographic examination were done. And the most frequent findings were dilatation of the proximal bile duct and abrupt narrowing or complete obstruction of distal lumen. In 27 cases (82%), complete obstruction of bile duct were noted. Attempts were made to analyze the type of obstruction: Constricted type in 39%, Nipple type in 18%, round or flat type (smooth or slightly irregular) in 15%, and serrated type in 9%. Incomplete obstruction were noted in 6 cases (18%). Among them, abrupt narrowing of lumen was noted in 9% and diffuse narrowing in 9%. 7. ERCP was done in 7 cases. Findings were: constricted type in 42.6%, constricted and slightly irregular type in 14.3%, downward convexity in 14.3%, diffuse irregular narrowing in 14.3% and intraluminal filing defect in 14.3%.

  14. Conservative Treatment for Cystic Duct Stenosis in a Child

    Directory of Open Access Journals (Sweden)

    Marco Gasparetto

    2013-01-01

    Full Text Available Introduction. Few cases of common bile duct stenosis have been reported in the literature, and observations of strictures in the cystic duct are even more rare. Surgical cholecystectomy is the treatment needed in most cases of gallbladder hydrops. This paper describes the diagnosis and successful medical treatment of a rare pediatric case of cystic duct stenosis and gallbladder hydrops. Case Report. A formerly healthy one-year-old girl was admitted with colicky abdominal pain. Blood tests were normal, except for an increase in transaminases. Abdominal ultrasound excluded intestinal intussusception and identified a distended gallbladder with biliary sludge. MR cholangiography revealed a dilated gallbladder containing bile sediment and no detectable cystic duct, while the rest of the intra- and extrahepatic biliary tree and hepatic parenchyma were normal. This evidence was consistent with gallbladder hydrops associated with cystic duct stenosis. The baby was treated with i.v. hydration, corticosteroids, antibiotics, and ursodeoxycholic acid. Her general condition rapidly improved, with no further episodes of abdominal pain and normalization of liver enzymes. This allowed to avoid cholecystectomy, and the child is well 1.5 years after diagnosis. Conclusions. Although cholecystectomy is usually necessary in case of gallbladder hydrops, our experience suggests that surgical procedures can be avoided when the distension is caused by a cystic duct stenosis.

  15. Gender Categorization in Cochlear Implant Users

    Science.gov (United States)

    Massida, Zoe; Marx, Mathieu; Belin, Pascal; James, Christopher; Fraysse, Bernard; Barone, Pascal; Deguine, Olivier

    2013-01-01

    Purpose: In this study, the authors examined the ability of subjects with cochlear implants (CIs) to discriminate voice gender and how this ability evolved as a function of CI experience. Method: The authors presented a continuum of voice samples created by voice morphing, with 9 intermediate acoustic parameter steps between a typical male and a…

  16. Fibro-vascular coupling in the control of cochlear blood flow.

    Directory of Open Access Journals (Sweden)

    Min Dai

    Full Text Available Transduction of sound in the cochlea is metabolically demanding. The lateral wall and hair cells are critically vulnerable to hypoxia, especially at high sound levels, and tight control over cochlear blood flow (CBF is a physiological necessity. Yet despite the importance of CBF for hearing, consensus on what mechanisms are involved has not been obtained.We report on a local control mechanism for regulating inner ear blood flow involving fibrocyte signaling. Fibrocytes in the super-strial region are spatially distributed near pre-capillaries of the spiral ligament of the albino guinea pig cochlear lateral wall, as demonstrably shown in transmission electron microscope and confocal images. Immunohistochemical techniques reveal the inter-connected fibrocytes to be positive for Na+/K+ ATPase β1 and S100. The connected fibrocytes display more Ca(2+ signaling than other cells in the cochlear lateral wall as indicated by fluorescence of a Ca(2+ sensor, fluo-4. Elevation of Ca(2+ in fibrocytes, induced by photolytic uncaging of the divalent ion chelator o-nitrophenyl EGTA, results in propagation of a Ca(2+ signal to neighboring vascular cells and vasodilation in capillaries. Of more physiological significance, fibrocyte to vascular cell coupled signaling was found to mediate the sound stimulated increase in cochlear blood flow (CBF. Cyclooxygenase-1 (COX-1 was required for capillary dilation.The findings provide the first evidence that signaling between fibrocytes and vascular cells modulates CBF and is a key mechanism for meeting the cellular metabolic demand of increased sound activity.

  17. Relationship Between Bile Duct Reconstruction and Complications in Living Donor Liver Transplantation.

    Science.gov (United States)

    Miyagi, S; Kawagishi, N; Kashiwadate, T; Fujio, A; Tokodai, K; Hara, Y; Nakanishi, C; Kamei, T; Ohuchi, N; Satomi, S

    2016-05-01

    In living donor liver transplantation (LDLT), the recipient bile duct is thin and short. Bile duct complications often occur in LDLT, with persistent long-term adverse effects. Recently, we began to perform microsurgical reconstruction of the bile duct. The purpose of this study was to investigate the relationship between bile duct reconstruction methods and complications in LDLT. From 1991 to 2014, we performed 161 LDLTs (pediatric:adult = 90:71; left lobe:right lobe = 95:66). In this study, we retrospectively investigated the initial bile duct complications in LDLT and performed univariate and multivariate analyses to identify the independent risk factors for complications. The most frequent complication was biliary stricture (9.9%), followed by biliary leakage (6.8%). On univariate and multiple logistic regression analysis, the independent risk factors for biliary stricture were bile leakage (P = .0103) and recurrent cholangitis (P = .0077). However, there were no risk factors for biliary leakage on univariate analysis in our study. The reconstruction methods (hepaticojejunostomy or duct-to-duct anastomosis) and reconstruction technique (with or without microsurgery) were not risk factors for biliary stricture and leakage. In this study, the most frequent complication of LDLT was biliary stricture. The independent risk factors for biliary stricture were biliary leakage and recurrent cholangitis. Duct-to-duct anastomosis and microsurgical reconstruction of the bile duct were not risk factors for biliary stricture and leakage. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Communication, Psychosocial, and Educational Outcomes of Children with Cochlear Implants and Challenges Remaining for Professionals and Parents

    Directory of Open Access Journals (Sweden)

    Renée Punch

    2011-01-01

    Full Text Available This paper provides an overview and a synthesis of the findings of a large, multifaceted study investigating outcomes from paediatric cochlear implantation. The study included children implanted at several Australian implant clinics and attending a variety of early intervention and educational settings across a range of locations in eastern Australia. It investigated three major aspects of childhood cochlear implantation: (1 parental expectations of their children's implantation, (2 families' decision-making processes, and (3 the communication, social, and educational outcomes of cochlear implantation for deaf children. It employed a mixed-methods approach in which quantitative survey data were gathered from 247 parents and 151 teachers, and qualitative data from semistructured interviews with 27 parents, 15 teachers, and 11 children and adolescents with cochlear implants. The summarised findings highlight several areas where challenges remain for implant clinics, parents, and educators if children with cochlear implants are to reach their full potential personally, educationally, and socially.

  19. An experimental study on microcholangiographic manifestation in extrahepatic bile duct obstruction

    International Nuclear Information System (INIS)

    Lee, Yul; Kang, Heung Sik; Park, Jae Hyung; Kim, Chu Wan

    1987-01-01

    Microcholangiographic using microbarium was done for radiological observation of the morphology of intrahepatic microbiliary system and its charge after extrahepatic bile duct obstruction. Regurgitation of microbarium into the systemic circulation was also observed. Extrahepatic bile ducts of 40 rabbits were ligated and microcholangiography was done just after ligation, after 1 day, 3 days and 5 days. Injection pressure of microbarium was 58 cm H 2 O in 20 rabbits and 93 cm H 2 O in another 20 rabbits. Histologic findings of the liver was compared with microcholangiographic findings. The results were as follows: 1. In microcholangiography, interlobular bile ducts and ductules were well noted, but bile canaliculi were not visible. 2. After extrahepatic bile duct ligation, ductules and small interlobular bile ducts were tortuously dilated and proliferated. These findings progressed according as the time after extrahepatic bile duct ligation especially between 1 and 2 days. 3. Microbarium was regurgitated into hepatic sinusoids from a portal tract due to rupture of interlobular bile ducts or ductules, and this was observed only in limited portions of sample tissue sections, but could be found in most of 40 rabbits. From the above results, the morphology of intrahepatic microbiliary system and its change after extrahepatic bile duct obstruction could be radiologically observed with microcholangiography, so this technique could be used for experimental study about the biliary system.

  20. Cochlear Implants Keep Twin Sisters Learning, Discovering Together

    Science.gov (United States)

    ... Current Issue Past Issues Special Section: Focus on Communication Cochlear Implants Past Issues / Fall 2008 Table of ... in noisy environments—a critical ability in a classroom. Before the second implant, Mia was pulling back ...

  1. Related issues in repair of bile duct injury and traumatic biliary stricture

    Directory of Open Access Journals (Sweden)

    WANG Shuguang

    2017-02-01

    Full Text Available Inappropriate treatment of bile duct injury and traumatic biliary stricture may cause serious consequences such as recurrent cholangitis, formation of hepatolithiasis, and biliary cirrhosis. This article elaborates on the influencing factors for the effect of the repair of bile duct injury and traumatic biliary stricture, repair principles, timing of repair or reconstruction, and related methods and techniques. It is pointed out that if there is no significant local infection and the bile duct wall defect is <2 cm, end-to-end anastomosis should be used for repair; if the bile duct wall defect is >2 cm, Roux-en-Y hepaticojejunostomy should be used for reconstruction. If the upper wall of the bile duct had a large defect and the lower wall has an integral structure, pedicled umbilical vein graft, pedicled jejunal wall seromuscular flap, or gastric wall seromuscular flap should be used for repair. The patients with severe congestion and edema at the site of injury should be treated with sufficient external drainage of the injured bile duct and then selective repair or reconstruction. Patients with hepatic duct stenosis in the liver lobe or hepatic segments and liver tissue atrophy can be treated with hepalobectomy or segmental hepatectomy. The key to successful repair is exposure and removal of high hilar bile duct stricture, while segmental hepatectomy of the Ⅳb segment can fully expose the left and right hepatic pedicles and help with the incision of the left and right hepatic ducts and secondary hepatic ducts, and therefore, it is a good method for exposing high bile duct stricture.

  2. Noise-induced cochlear synaptopathy in rhesus monkeys (Macaca mulatta).

    Science.gov (United States)

    Valero, M D; Burton, J A; Hauser, S N; Hackett, T A; Ramachandran, R; Liberman, M C

    2017-09-01

    Cochlear synaptopathy can result from various insults, including acoustic trauma, aging, ototoxicity, or chronic conductive hearing loss. For example, moderate noise exposure in mice can destroy up to ∼50% of synapses between auditory nerve fibers (ANFs) and inner hair cells (IHCs) without affecting outer hair cells (OHCs) or thresholds, because the synaptopathy occurs first in high-threshold ANFs. However, the fiber loss likely impairs temporal processing and hearing-in-noise, a classic complaint of those with sensorineural hearing loss. Non-human primates appear to be less vulnerable to noise-induced hair-cell loss than rodents, but their susceptibility to synaptopathy has not been studied. Because establishing a non-human primate model may be important in the development of diagnostics and therapeutics, we examined cochlear innervation and the damaging effects of acoustic overexposure in young adult rhesus macaques. Anesthetized animals were exposed bilaterally to narrow-band noise centered at 2 kHz at various sound-pressure levels for 4 h. Cochlear function was assayed for up to 8 weeks following exposure via auditory brainstem responses (ABRs) and otoacoustic emissions (OAEs). A moderate loss of synaptic connections (mean of 12-27% in the basal half of the cochlea) followed temporary threshold shifts (TTS), despite minimal hair-cell loss. A dramatic loss of synapses (mean of 50-75% in the basal half of the cochlea) was seen on IHCs surviving noise exposures that produced permanent threshold shifts (PTS) and widespread hair-cell loss. Higher noise levels were required to produce PTS in macaques compared to rodents, suggesting that primates are less vulnerable to hair-cell loss. However, the phenomenon of noise-induced cochlear synaptopathy in primates is similar to that seen in rodents. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Pharmacokinetic Properties of Adenosine Amine Congener in Cochlear Perilymph after Systemic Administration

    Directory of Open Access Journals (Sweden)

    Hao Chang

    2017-01-01

    Full Text Available Noise-induced hearing loss (NIHL is a global health problem affecting over 5% of the population worldwide. We have shown previously that acute noise-induced cochlear injury can be ameliorated by administration of drugs acting on adenosine receptors in the inner ear, and a selective A1 adenosine receptor agonist adenosine amine congener (ADAC has emerged as a potentially effective treatment for cochlear injury and resulting hearing loss. This study investigated pharmacokinetic properties of ADAC in rat perilymph after systemic (intravenous administration using a newly developed liquid chromatography-tandem mass spectrometry detection method. The method was developed and validated in accordance with the USA FDA guidelines including accuracy, precision, specificity, and linearity. Perilymph was sampled from the apical turn of the cochlea to prevent contamination with the cerebrospinal fluid. ADAC was detected in cochlear perilymph within two minutes following intravenous administration and remained in perilymph above its minimal effective concentration for at least two hours. The pharmacokinetic pattern of ADAC was significantly altered by exposure to noise, suggesting transient changes in permeability of the blood-labyrinth barrier and/or cochlear blood flow. This study supports ADAC development as a potential clinical otological treatment for acute sensorineural hearing loss caused by exposure to traumatic noise.

  4. Radiological study on the change of duct-ligated parotid gland

    International Nuclear Information System (INIS)

    Ohnishi, Takashi

    1994-01-01

    The change of the parotid gland with time following ligation of the main duct was investigated. The duct-ligated parotid gland in rabbit was examined by salivary gland scintigraphy with 99m Tc-pertechnetate ( 99m TcO 4 - ), sialography and microscopic observation. The third day after ligation of the main duct, the outward form of the parotid gland on the static scintigram was not well-defined. On the seventh day, 99m TcO 4 - accumulation was decreased slightly. On the 14th day, atrophy of the parotid gland occurred. The degree of atrophy produced by ligation increases as the duration of the ligation increases. On the 42nd day, the presence of the parotid gland was not recorded practically. The main duct was dilated on the third day. On the seventh day, the intraglandular ducts were bent and strictured. Disappearance of the peripheral duct and atrophy of the parotid gland parenchyma was observed. On microscopic observation, the intraglandular tributaries and the lumen were dilated on the third day. And the reticular fiber was observed that was irregularly formed in parts. The acinar cells were pressed by large and small dilated lumen on the seventh day. On the 14th day, the collagenous fiber around the acini and the duct was increased still more. In addition, fibrosis of the lobule interspace was observed. The degree of atrophy of the acini and lobule was increased maximally on the 42nd day. These results of the salivary gland scintigraphy closely connected with sialograms and microscopic findings. The parotid gland tissue decreases and changings of the duct system were indicated by these imaging methods in detail. (author)

  5. Modified duval procedure for small-duct chronic pancreatitis without head dominance.

    Science.gov (United States)

    Oida, Takatsugu; Aramaki, Osamu; Kano, Hisao; Mimatsu, Kenji; Kawasaki, Atsushi; Kuboi, Youichi; Fukino, Nobutada; Kida, Kazutoshi; Amano, Sadao

    2011-01-01

    In the case of small-duct chronic pancreatitis, surgery for pain relief is broadly divided into resection and drainage procedures. These procedures should be selected according to the location of dominant lesion, diameter of the pancreatic duct and extent of the disease. The appropriate procedure for the treatment of small-duct chronic pancreatitis, especially small-duct chronic pancreatitis without head dominance, remains controversial. We developed the modified Duval procedure for the treatment of small-duct chronic pancreatitis without head dominance and determined the efficacy of this procedure. We retrospectively studied 14 patients who underwent surgical drainage with or without pancreatic resection for chronic pancreatitis with small pancreatic duct (Puestow procedure group and the modified Duval procedure group. No complications occurred in the modified Duval group. In the modified Puestow procedure group, complete and partial pain relief were observed in 62.5%, and 37.5% of patients respectively. In contrast, complete pain relief was observed in all the patients in the modified Duval procedure group. Our modified Duval procedure is useful and should be considered the appropriate surgical technique for the treatment of small-duct chronic pancreatitis without head dominance.

  6. A simple method to calculate the neutron flow through full ducts

    International Nuclear Information System (INIS)

    Faik Ouahab, Z.; Jehouani, A.; Ghassoun, J.; Senhou, N.; Groetz, J.E.

    2010-01-01

    Summary of a study of assessment of the probability for neutrons to be guided in a full duct with a square cross section and doubly bent. Two software have been developed, based on the Monte Carlo simulation, to compute the neutron transmission probability at the end of the duct. Results are in good agreement with that obtained with the MCNP-5 code. The neutron flow and probability at the duct end have been determined for different materials and different duct dimensions

  7. Intracellular pH in rat pancreatic ducts

    DEFF Research Database (Denmark)

    Novak, I; Hug, M; Greger, R

    1997-01-01

    In order to study the mechanism of H+ and HCO3- transport in a HCO3- secreting epithelium, pancreatic ducts, we have measured the intracellular pH (pHi) in this tissue using the pH sensitive probe BCECF. We found that exposures of ducts to solutions containing acetate/acetic acid or NH4+/NH3...... buffers (20 mmol/l) led to pHi changes in accordance with entry of lipid-soluble forms of the buffers, followed by back-regulation of pHi by duct cells. In another type of experiment, changes in extracellular pH of solutions containing HEPES or HCO3-/CO2 buffers led to significant changes in pHi that did....... Under some conditions, these exchangers can be invoked to regulate cell pH....

  8. Salivary duct carcinoma: a Danish national study

    DEFF Research Database (Denmark)

    Breinholt, Helle; Elhakim, Mohammad Talal; Godballe, Christian

    2016-01-01

    BACKGROUND: To present the first national series of salivary duct carcinoma patients, including survival rates and an analysis of prognostic factors. METHODS: By merging three Danish nationwide registries that encompass an entire population, 34 patients diagnosed with salivary duct carcinoma from......-rank test. RESULTS: Salivary duct carcinoma showed an incidence of 0.04/100.000 inhabitants/year. Distant recurrence was seen in 52% of patients. Five-year overall survival, disease-specific survival and recurrence-free survival were 32%, 42% and 35%, respectively. Univariate analyses suggested that overall...... carcinoma incidence averages to two episodes per year in the entire Kingdom of Denmark. With half of patients in this study experiencing distant recurrences and only a third surviving at 5 years, prognosis is dismal. Advanced overall stage, vascular invasion and involved resection margins all seem...

  9. Temporal and spectral contributions to musical instrument identification and discrimination among cochlear implant users.

    Science.gov (United States)

    Prentiss, Sandra M; Friedland, David R; Fullmer, Tanner; Crane, Alison; Stoddard, Timothy; Runge, Christina L

    2016-09-01

    To investigate the contributions of envelope and fine-structure to the perception of timbre by cochlear implant (CI) users as compared to normal hearing (NH) listeners. This was a prospective cohort comparison study. Normal hearing and cochlear implant patients were tested. Three experiments were performed in sound field using musical notes altered to affect the characteristic pitch of an instrument and the acoustic envelope. Experiment 1 assessed the ability to identify the instrument playing each note, while experiments 2 and 3 assessed the ability to discriminate the different stimuli. Normal hearing subjects performed better than CI subjects in all instrument identification tasks, reaching statistical significance for 4 of 5 stimulus conditions. Within the CI population, acoustic envelope modifications did not significantly affect instrument identification or discrimination. With envelope and pitch cues removed, fine structure discrimination performance was similar between normal hearing and CI users for the majority of conditions, but some specific instrument comparisons were significantly more challenging for CI users. Cochlear implant users perform significantly worse than normal hearing listeners on tasks of instrument identification. However, cochlear implant listeners can discriminate differences in envelope and some fine structure components of musical instrument sounds as well as normal hearing listeners. The results indicated that certain fine structure cues are important for cochlear implant users to make discrimination judgments, and therefore may affect interpretation toward associating with a specific instrument for identification.

  10. Scintigraphy of cysts of the common bile duct in children

    International Nuclear Information System (INIS)

    Mironov, S.P.; Akopyan, V.G.; Murieva, Z.D.; Tumanyan, G.T.; Mironova, E.S.

    1984-01-01

    Cyst of the common bile duct, the most frequent variant of cystic dilatation of the extrahepatic biliary tract, represents a serious diagnostic problem. 13 children with cysts of the common bile duct were studied by the method of dynamic scintigraphy with sup(99m)Tc-HIDA. The scintigraphic picture was characterized by the following signs: sacculated or spheroidal dilatation of the common bile duct, dilatation of the left or both lobular bile ducts, absence of the gall bladder visualization. Change of indicators of the hepatic function and the time of interstinal visualization reflects both the disorder of distal parts permeability and the degree of cyst drainage. An experience of radioisotropic cholegraphy application reveals, that the efficiency of preoperational diagnosis of cysts of the common bile duct increases as a result of the more accurate evaluation of the dynamic of improvement of absorptive-excretory hepatic function after different variants of operations

  11. Effects of explosion-generated shock waves in ducts

    International Nuclear Information System (INIS)

    Busby, M.R.; Kahn, J.E.; Belk, J.P.

    1976-01-01

    An explosion in a space causes an increase in temperature and pressure. To quantify the challenge that will be presented to essential components in a ventilation system, it is necessary to analyze the dynamics of a shock wave generated by an explosion, with attention directed to the propagation of such a wave in a duct. Using the equations of unsteady flow and shock tube theory, a theoretical model has been formulated to provide flow properties behind moving shock waves that have interacted with various changes in duct geometry. Empirical equations have been derived to calculate air pressure, temperature, Mach number, and velocity in a duct following an explosion

  12. Occlusion of the cystic duct by electrocoagulation: A radiologic technique

    International Nuclear Information System (INIS)

    Becker, C.D.; Quenville, W.F.; Burhenne, H.J.

    1987-01-01

    Chemical dissolution and extracorporeal shock wave lithotripsy are promising new methods for the treatment of cholelithiasis without cholecystectomy. Nonsurgical defunctionalization of the gallbladder is now required to prevent recurrent stone formation. The authors consider cystic duct occlusion to be the first step. Ten domestic pigs underwent transcatheter electrocoagulation of the cystic duct via a cholecystostomy under fluoroscopic control. Stricture formation was followed by complete cystic duct occlusion in all ten cases. After a follow-up period ranging from 2 to 17 weeks (mean, 13 weeks), the animals were killed. Histologic studies demonstrated that complete obliteration of the cystic duct lumen was due to fibrous scar formation

  13. The Construct Validity and Reliability of an Assessment Tool for Competency in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Patorn Piromchai

    2014-01-01

    Full Text Available Introduction. We introduce a rating tool that objectively evaluates the skills of surgical trainees performing cochlear implant surgery. Methods. Seven residents and seven experts performed cochlear implant surgery sessions from mastoidectomy to cochleostomy on a standardized virtual reality temporal bone. A total of twenty-eight assessment videos were recorded and two consultant otolaryngologists evaluated the performance of each participant using these videos. Results. Interrater reliability was calculated using the intraclass correlation coefficient for both the global and checklist components of the assessment instrument. The overall agreement was high. The construct validity of this instrument was strongly supported by the significantly higher scores in the expert group for both components. Conclusion. Our results indicate that the proposed assessment tool for cochlear implant surgery is reliable, accurate, and easy to use. This instrument can thus be used to provide objective feedback on overall and task-specific competency in cochlear implantation.

  14. Parametric model of the scala tympani for haptic-rendered cochlear implantation.

    Science.gov (United States)

    Todd, Catherine; Naghdy, Fazel

    2005-01-01

    A parametric model of the human scala tympani has been designed for use in a haptic-rendered computer simulation of cochlear implant surgery. It will be the first surgical simulator of this kind. A geometric model of the Scala Tympani has been derived from measured data for this purpose. The model is compared with two existing descriptions of the cochlear spiral. A first approximation of the basilar membrane is also produced. The structures are imported into a force-rendering software application for system development.

  15. Modeling of Auditory Neuron Response Thresholds with Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Frederic Venail

    2015-01-01

    Full Text Available The quality of the prosthetic-neural interface is a critical point for cochlear implant efficiency. It depends not only on technical and anatomical factors such as electrode position into the cochlea (depth and scalar placement, electrode impedance, and distance between the electrode and the stimulated auditory neurons, but also on the number of functional auditory neurons. The efficiency of electrical stimulation can be assessed by the measurement of e-CAP in cochlear implant users. In the present study, we modeled the activation of auditory neurons in cochlear implant recipients (nucleus device. The electrical response, measured using auto-NRT (neural responses telemetry algorithm, has been analyzed using multivariate regression with cubic splines in order to take into account the variations of insertion depth of electrodes amongst subjects as well as the other technical and anatomical factors listed above. NRT thresholds depend on the electrode squared impedance (β = −0.11 ± 0.02, P<0.01, the scalar placement of the electrodes (β = −8.50 ± 1.97, P<0.01, and the depth of insertion calculated as the characteristic frequency of auditory neurons (CNF. Distribution of NRT residues according to CNF could provide a proxy of auditory neurons functioning in implanted cochleas.

  16. Cochlear implantation in children with Jervell and Lange-Nielsen syndrome - a cautionary tale.

    Science.gov (United States)

    Broomfield, Stephen J; Bruce, Iain A; Henderson, Lise; Ramsden, Richard T; Green, Kevin M J

    2012-08-01

    Jervell and Lange-Nielsen (JLN) syndrome is a rare cause of congenital profound hearing loss associated with a prolonged QT interval on the electrocardiogram. Children presenting for cochlear implantation with this condition may be asymptomatic but are at risk of sudden death. SCREENING AND SUBSEQUENT: careful management is therefore required to ensure a successful outcome. We present our experience of cochlear implantation in children with JLN syndrome, including two who died unexpectedly, and suggest a protocol for management of such cases. Clinical presentation Four cases of cochlear implantation in JLN syndrome are described. None had any previous cardiological family history. Two were diagnosed pre-operatively but, despite appropriate management under a cardiologist, died from cardiac arrest; the first in the perioperative period following reimplantation for infection, and the second unrelated to his cochlear implant surgery. The other two patients were diagnosed only subsequent to their implantation and continue to use their implants successfully. These cases highlight the variation in presentation of JLN syndrome, and the spectrum of disease severity that exists. Our protocol stresses the importance of careful assessment and counselling of parents by an experienced implant team.

  17. Study of the Carrier-Aided Thin Film Electrode Array Design for Cochlear Insertion

    Directory of Open Access Journals (Sweden)

    Yuchen Xu

    2018-04-01

    Full Text Available The micro-fabricated thin film electrode array (TFEA has been a promising design for cochlear implants (CIs because of its cost-effectiveness and fabrication precision. The latest polymer-based cochlear TFEAs have faced difficulties for cochlear insertion due to the lack of structural stiffness. To stiffen the TFEA, dissolvable stiffening materials, TFEAs with different structures, and TFEAs with commercial CIs as carriers have been invested. In this work, the concept of enhancing a Parylene TFEA with Kapton tape as a simpler carrier for cochlear insertion has been proved to be feasible. The bending stiffness of the Kapton-aided TFEA was characterized with an analytical model, a finite element model, and a cantilever bending experiment, respectively. While the Kapton tape increased the bending stiffness of the Parylene TFEA by 103 times, the 6-μm-thick TFEA with a similar Young’s modulus, as a polyimide, in turn significantly increased the bending stiffness of the 170-μm-thick Kapton carrier by 60%. This result indicated that even the TFEA is ultra-flexible and that its bending stiffness should not be neglected in the design or selection of its carrier.

  18. Forced convection heat transfer correlation for finned plates in a duct

    International Nuclear Information System (INIS)

    Chae, Myeong-Seon; Moon, Je-Young; Chung, Bum-Jin

    2014-01-01

    Forced convection heat transfer experiments were conducted for plate-fin in a duct using various fin spacing, fin height, duct width, Reynolds number for Prandtl numbers 2,014. Based upon analogy concept, mass transfer rate were measured instead of heat transfer rates. The heat transfer rates were enhanced with the increase of fin height and decrease of fin spacing as they increase the heat transfer area. Meanwhile, heat transfer rates were impaired with the increase of the duct width as the bypass flows increased to tip clearance region. Forced convection heat transfer correlations were developed for laminar and turbulent flow conditions and for narrow and wide ducts. The work draws attention to the tip clearance on the heat transfer of the finned plate in a duct. (author)

  19. HAARP-Induced Ionospheric Ducts

    International Nuclear Information System (INIS)

    Milikh, Gennady; Vartanyan, Aram

    2011-01-01

    It is well known that strong electron heating by a powerful HF-facility can lead to the formation of electron and ion density perturbations that stretch along the magnetic field line. Those density perturbations can serve as ducts for ELF waves, both of natural and artificial origin. This paper presents observations of the plasma density perturbations caused by the HF-heating of the ionosphere by the HAARP facility. The low orbit satellite DEMETER was used as a diagnostic tool to measure the electron and ion temperature and density along the satellite orbit overflying close to the magnetic zenith of the HF-heater. Those observations will be then checked against the theoretical model of duct formation due to HF-heating of the ionosphere. The model is based on the modified SAMI2 code, and is validated by comparison with well documented experiments.

  20. Speech and language development in cognitively delayed children with cochlear implants.

    Science.gov (United States)

    Holt, Rachael Frush; Kirk, Karen Iler

    2005-04-01

    The primary goals of this investigation were to examine the speech and language development of deaf children with cochlear implants and mild cognitive delay and to compare their gains with those of children with cochlear implants who do not have this additional impairment. We retrospectively examined the speech and language development of 69 children with pre-lingual deafness. The experimental group consisted of 19 children with cognitive delays and no other disabilities (mean age at implantation = 38 months). The control group consisted of 50 children who did not have cognitive delays or any other identified disability. The control group was stratified by primary communication mode: half used total communication (mean age at implantation = 32 months) and the other half used oral communication (mean age at implantation = 26 months). Children were tested on a variety of standard speech and language measures and one test of auditory skill development at 6-month intervals. The results from each test were collapsed from blocks of two consecutive 6-month intervals to calculate group mean scores before implantation and at 1-year intervals after implantation. The children with cognitive delays and those without such delays demonstrated significant improvement in their speech and language skills over time on every test administered. Children with cognitive delays had significantly lower scores than typically developing children on two of the three measures of receptive and expressive language and had significantly slower rates of auditory-only sentence recognition development. Finally, there were no significant group differences in auditory skill development based on parental reports or in auditory-only or multimodal word recognition. The results suggest that deaf children with mild cognitive impairments benefit from cochlear implantation. Specifically, improvements are evident in their ability to perceive speech and in their reception and use of language. However, it may

  1. Laparoscopic bile duct injury: understanding the psychology and heuristics of the error.

    Science.gov (United States)

    Dekker, Sidney W A; Hugh, Thomas B

    2008-12-01

    Bile duct injury is an important unsolved problem of laparoscopic cholecystectomy, occurring with unacceptable frequency even in the hands of experienced surgeons. This suggests that a systemic predisposition to the injury is intrinsic to cholecystectomy and indicates that an analysis of the psychology and heuristics of surgical decision-making in relation to duct identification may be a guide to prevention. Review of published reports on laparoscopic bile duct injury from 1997 to 2007 was carried out. An analysis was also carried out of the circumstances of the injuries in 49 patients who had transection of an extrahepatic bile duct and who were referred for reconstruction or were assessed in a medicolegal context. Special emphasis was placed on identifying the possible psychological aspects of duct misidentification. Review of published work showed an emphasis on the technical aspects of correct identification of the cystic duct, with few papers addressing the heuristics and psychology of surgical decision-making during cholecystectomy. Duct misidentification was the cause of injury in 42 out of the 49 reviewed patients (86%). The injury was not recognized at operation in 70% and delay in recognition persisted into the postoperative period in 57%. Underestimation of risk, cue ambiguity and visual misperception ('seeing what you believe') were important factors in misidentification. Delay in recognition of the injury is a feature consistent with cognitive fixation and plan continuation, which help construct and sustain the duct misidentification during the operation and beyond. Changing the 'culture' of cholecystectomy is probably the most effective strategy for preventing laparoscopic bile duct injury, especially if combined with new technical approaches and an understanding of the heuristics and psychology of the duct misidentification error. Training of surgeons for laparoscopic cholecystectomy should emphasize the need to be alert for cues that the incorrect

  2. Can cochlear implantation improve neurocognition in the aging population?

    Directory of Open Access Journals (Sweden)

    Völter C

    2018-04-01

    Full Text Available Christiane Völter,1 Lisa Götze,1 Stefan Dazert,1 Michael Falkenstein,2,3 Jan Peter Thomas1 1Department of Otorhinolaryngology, Head and Neck Surgery, Ruhr University Bochum, St. Elisabeth-Hospital, Bochum, Germany; 2Institute for Work, Learning and Ageing (ALA, Bochum, Germany; 3Leibniz Research Centre for Working Environment and Human Factors, Dortmund, Germany Introduction: The relationship between cognition and the ability to hear is well known. Due to changes in demographics, the number of people with sensorineural hearing loss and cognitive impairment is increasing. The aim of this study was to identify the impact of hearing rehabilitation via cochlear implantation on cognitive decline among the aging population. Patients and methods: This prospective study included 60 subjects aged between 50 and 84 years (mean 65.8 years, SD=8.9 with a severe to profound bilateral hearing impairment. A computer-based evaluation of short- and long-term memory, processing speed, attention, working memory and inhibition was performed prior to surgery as well as 6 and 12 months after cochlear implantation. Additionally, speech perception at 65 and 80 dB (Freiburger monosyllabic speech test as well as disease-related (Nijmegen Cochlear Implant Questionnaire and general (WHOQOL-OLD quality of life were assessed. Results: Six months postimplantation, speech perception, quality of life and also neurocognitive abilities significantly increased. The most remarkable improvement after 6 months was detected in executive functions such as attention (p<0.001, inhibition (p=0.025 and working memory (n-back: p=0.002; operation span task: p=0.008, followed by delayed recall (p=0.03. In contrast, long-term memory showed a significant change of performance only after 12 months (p=0.021. After 6 months, most cognitive domains remained stable, except working memory assessed by the operation span task, which significantly improved between 6 and 12 months (p<0.001. No

  3. Recognition of "real-world" musical excerpts by cochlear implant recipients and normal-hearing adults.

    Science.gov (United States)

    Gfeller, Kate; Olszewski, Carol; Rychener, Marly; Sena, Kimberly; Knutson, John F; Witt, Shelley; Macpherson, Beth

    2005-06-01

    The purposes of this study were (a) to compare recognition of "real-world" music excerpts by postlingually deafened adults using cochlear implants and normal-hearing adults; (b) to compare the performance of cochlear implant recipients using different devices and processing strategies; and (c) to examine the variability among implant recipients in recognition of musical selections in relation to performance on speech perception tests, performance on cognitive tests, and demographic variables. Seventy-nine cochlear implant users and 30 normal-hearing adults were tested on open-set recognition of systematically selected excerpts from musical recordings heard in real life. The recognition accuracy of the two groups was compared for three musical genre: classical, country, and pop. Recognition accuracy was correlated with speech recognition scores, cognitive measures, and demographic measures, including musical background. Cochlear implant recipients were significantly less accurate in recognition of previously familiar (known before hearing loss) musical excerpts than normal-hearing adults (p genre. Implant recipients were most accurate in the recognition of country items and least accurate in the recognition of classical items. There were no significant differences among implant recipients due to implant type (Nucleus, Clarion, or Ineraid), or programming strategy (SPEAK, CIS, or ACE). For cochlear implant recipients, correlations between melody recognition and other measures were moderate to weak in strength; those with statistically significant correlations included age at time of testing (negatively correlated), performance on selected speech perception tests, and the amount of focused music listening following implantation. Current-day cochlear implants are not effective in transmitting several key structural features (i.e., pitch, harmony, timbral blends) of music essential to open-set recognition of well-known musical selections. Consequently, implant

  4. Abnormalities of intrahepatic bile ducts in extrahepatic biliary atresia.

    Science.gov (United States)

    Raweily, E A; Gibson, A A; Burt, A D

    1990-12-01

    The infantile cholangiopathies are a group of conditions associated with neonatal jaundice, which include extrahepatic biliary atresia, paucity of intra-hepatic bile ducts and disorders associated with persistence of fetal biliary structures, the so-called ductal plate malformations. Although previously regarded as distinct entities, it has recently been suggested that they may represent parts of a disease spectrum in which the principal process is one of bile duct destruction, the morphological manifestations in individual cases being influenced by the stage of intra-uterine development at which such injury occurs and by the site within the biliary system at which there is maximum damage. To further examine this concept, we have studied liver biopsy specimens from 37 neonates with extrahepatic biliary atresia, with particular reference to abnormalities of the intrahepatic bile ducts. Paucity of intrahepatic ducts, defined as a bile duct: portal tract ratio of less than 0.9, was identified in six cases (16.2%). In eight cases (21.6%) we found concentric tubular ductal structures similar to those observed in ductal plate malformations. In one case, both abnormalities could be demonstrated. Our findings support the concept that there is overlap between the various types of infantile cholangiopathy.

  5. Primary Follicular Lymphoma of the Common Bile Duct Mimicking Cholangiocarcinoma

    Directory of Open Access Journals (Sweden)

    Khaled Youssef Elbanna

    2014-01-01

    Full Text Available Primary non-Hodgkin′s lymphoma of the common bile duct is extremely rare. We present a case with history of inflammatory bowel disease and clinical manifestations of obstructive jaundice. Abdominal magnetic resonance imaging with magnetic resonance cholangiopancreatography (MRCP was done and demonstrated tight stricture at the middle part of common bile duct, and radiological findings were supportive of extra-hepatic cholangiocarcinoma. Whipple′s procedure was performed and the case was histopathologically proven to be non-Hodgkin′s lymphoma of follicular subtype involving the common bile duct. Lymphoma of the hepatobiliary system is usually present as secondary manifestation of systemic malignant lymphoma. However, primary malignant lymphomas arising from the hepatobiliary tree are extremely rare. The radiological appearance of common bile duct lymphoma is very similar to cholangiocarcinoma, making preoperative diagnosis very difficult, as in our present case. We also compare the imaging findings of our case to those seen in reported cases of follicular lymphoma of the common bile duct.

  6. Surgical complications following cochlear implantation in adults based on a proposed reporting consensus

    DEFF Research Database (Denmark)

    Jeppesen, Jonas; Faber, Christian Emil

    2013-01-01

    Abstract Conclusion: The rate of severe complications was low and cochlear implantation is a relatively safe procedure. Standardization is crucial when reporting on cochlear implant complications to ensure comparability between studies. A consensus on the reporting of complications proposed by a ...... occurred following one implantation (0.3%). Transient chorda tympani syndrome (30.8%), vertigo/dizziness (29.5%) and tinnitus (4.9%) were the most frequent minor complications....

  7. Spontaneous common bile duct perforation—A rare clinical entity

    Directory of Open Access Journals (Sweden)

    Melissa Amberger

    Full Text Available Introduction: Spontaneous common bile duct perforation is an uncommon clinical entity in both adults and children. Few case reports have been published since the first clinical description in 1882. Our work has been reported in line with SCARE criteria. Presentation of case: Herein, we describe the case of a 28 year-old female who suffered spontaneous common bile duct perforation while admitted for choledocholithiasis. Discussion: The perforation occurred while in-hospital, and extensive imaging and laboratory tests characterized the disease in detail. To our knowledge, this is the first report of spontaneous common bile duct perforation witnessed from pre-perforation through definitive management. Conclusion: Physicians and Surgeons should seek out this uncommon diagnosis in the patient with suspected Choledocholithiasis who suddenly become peritoneal on physical exam so that definitive care can be expedited. Keywords: Common bile duct, Biliary peritonitis, Choledocholithiasis

  8. Bile Duct Cancer (Cholangiocarcinoma) Symptoms, Tests, Prognosis, and Stages (PDQ®)—Patient Version

    Science.gov (United States)

    Bile duct cancer, or cholangiocarcinoma, is rare. Bile ducts are tubes that carry bile between the liver, gallbladder, and small intestine. Bile duct cancer can occur in the intrahepatic, perihilar (Klatskin tumor), or distal extrahepatic area. Learn about tests to diagnose and the stages of bile duct cancer.

  9. Evidence for a Na+-Ca2+ exchanger in rat pancreatic ducts

    DEFF Research Database (Denmark)

    Hug, M; Pahl, C; Novak, I

    1996-01-01

    Only recently has it been recognized that intracellular Ca2+ is an important cellular mediator in pancreatic ducts. The aim of the present study was to characterize the Ca2+ efflux pathway in ducts freshly prepared from rat pancreas. Lowering of extracellular Na+ concentration resulted in a signi......Only recently has it been recognized that intracellular Ca2+ is an important cellular mediator in pancreatic ducts. The aim of the present study was to characterize the Ca2+ efflux pathway in ducts freshly prepared from rat pancreas. Lowering of extracellular Na+ concentration resulted...

  10. Design requirement on KALIMER blanket fuel assembly duct

    International Nuclear Information System (INIS)

    Hwang, Woan; Kang, H. Y.; Nam, C.; Kim, J. O.

    1998-03-01

    This document describes design requirements which are needed for designing the blanket fuel assembly duct of the KALIMER as design guidance. The blanket fuel assembly duct of the KALIMER consists of fuel rods, mounting rail, nosepiece, duct with pad, handling socket with pad. Blanket fuel rod consists of top end plug, bottom end plug with solid ferritic-martensitic steel rod and key way blanket fuel slug, cladding, and wire wrap. In the assembly, the rods are in a triangular pitch array, and the rod bundle is attached to the nosepiece with mounting rails. The bottom end of the assembly duct is formed by a long nosepiece which provides the lower restraint function and the paths for coolant inlet. This report contains functional requirements, performance and operational requirements, interfacing systems requirements, core restraint and interface requirements, design limits and strength requirements, system configuration and essential feature requirements, seismic requirements, structural requirements, environmental requirements, reliability and safety requirements, standard and codes, QA programs, and other requirements. (author). 20 refs., 4 figs

  11. Heat transfer in an asymmetrically heated duct, 2

    International Nuclear Information System (INIS)

    Satoh, Isao; Kurosaki, Yasuo

    1986-01-01

    The objective of this article is to study theoretically and experimentally the effects of nonuniform heating on turbulent heat transfer characteristics for flow in a horizontal rectangular duct ; a vertical side wall was uniformly heated, and the other wall were insulated. In our theoretical approach, the zero-equation model for turbulent eddy viscosity was employed. The effects of mesh size of finite difference on the calculation results were examined, and some refined compensation for wall temperatures and wall shear stresses by no use of fine mesh were proposed to reduce the calculation time. The heat transfer coefficients in thermally developing region for a nonuniformly heated duct obtained from numerical solutions are larger than the one for uniformly heated case. The buoyancy effects on heat transfer were evaluated. However, it was seen that the secondary flow due to buoyancy force was hardly expected to enhance heat transfer in a turbulent duct flow. Experiments were performed to measure the velocity and temperature profiles in a turbulent duct flow with a nonuniform heated wall. The experimental results were in good agreement with the theoretical ones. (author)

  12. Cochlear implant magnet retrofit.

    Science.gov (United States)

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  13. Self-esteem and social well-being of children with cochlear implant compared to normal-hearing children

    DEFF Research Database (Denmark)

    Percy-Smith, L.; Caye-Thomasen, P.; Gudman, M.

    2008-01-01

    Objective: The purpose of this study was to make a quantitative comparison of parameters of self-esteem and social well-being between children with cochlear implants and normal-hearing children. Material and methods: Data were obtained from 164 children with cochlear implant (CI) and 2169 normal......-hearing children (NH). Parental questionnaires, used in a national survey assessing the self-esteem and well-being of normal-hearing children, were applied to the cochlear implanted group, in order to allow direct comparisons. Results: The children in the CI group rated significantly higher on questions about well...... overall self-esteem or number of friends. The two groups of children scored similarly on being confident, independent, social, not worried and happy. Conclusion: Children with cochlear implant score equal to or better than their normal-hearing peers on matters of self-esteem and social well-being. (C...

  14. Simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome.

    Science.gov (United States)

    Alsanosi, A A

    2015-09-01

    To report a rare case of simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome. Case report. A five-month-old boy with Usher syndrome and congenital profound bilateral deafness underwent simultaneous bilateral cochlear implantation. The decision to perform implantation in such a young child was based on his having a supportive family and the desire to foster his audiological development before his vision deteriorated. The subject experienced easily resolvable intra- and post-operative adverse events, and was first fitted with an externally worn audio processor four weeks after implantation. At 14 months of age, his audiological development was age-appropriate. Simultaneous bilateral cochlear implantation is possible, and even advisable, in children as young as five months old when performed by an experienced implantation team.

  15. Paediatric Cochlear Implantation in Patients with Waardenburg Syndrome.

    Science.gov (United States)

    van Nierop, Josephine W I; Snabel, Rebecca R; Langereis, Margreet; Pennings, Ronald J E; Admiraal, Ronald J C; Mylanus, Emmanuel A M; Kunst, Henricus P M

    2016-01-01

    To analyse the benefit of cochlear implantation in young deaf children with Waardenburg syndrome (WS) compared to a reference group of young deaf children without additional disabilities. A retrospective study was conducted on children with WS who underwent cochlear implantation at the age of 2 years or younger. The post-operative results for speech perception (phonetically balanced standard Dutch consonant-vocal-consonant word lists) and language comprehension (the Reynell Developmental Language Scales, RDLS), expressed as a language quotient (LQ), were compared between the WS group and the reference group by using multiple linear regression analysis. A total of 14 children were diagnosed with WS, and 6 of them had additional disabilities. The WS children were implanted at a mean age of 1.6 years and the 48 children of the reference group at a mean age of 1.3 years. The WS children had a mean phoneme score of 80% and a mean LQ of 0.74 at 3 years post-implantation, and these results were comparable to those of the reference group. Only the factor additional disabilities had a significant negative influence on auditory perception and language comprehension. Children with WS performed similarly to the reference group in the present study, and these outcomes are in line with the previous literature. Although good counselling about additional disabilities concomitant to the syndrome is relevant, cochlear implantation is a good rehabilitation method for children with WS. © 2016 S. Karger AG, Basel.

  16. Complications in cochlear implantation at the Clinical Center of Vojvodina

    Directory of Open Access Journals (Sweden)

    Dankuc Dragan

    2015-01-01

    Full Text Available Introduction. The first modern cochlear implantation in Serbia was performed on November 26, 2002 at the Center for Cochlear Implantation of the Clinic for Ear, Nose and Throat Diseases, Clinical Center of Vojvodina. Objective. The aim of the paper is the analysis of intraoperative and postoperative complications. Major complications include those resulting in the necessity for revision surgery, explantation, reimplantation, severe disease or even lethal outcomes. Minor complications resolve spontaneously or can be managed by conservative therapy and do not require any prolonged hospitalization of the patient. Methods. In the 2002-2013 period, 99 patients underwent surgical procedures and 100 cochlear implants were placed. Both intraoperative and postoperative complications were analyzed in the investigated patient population. Results. The analysis encompassed 99 patients, the youngest and the oldest ones being one year old and 61 years old, respectively. The complications were noticed in 11 patients, i.e. in 10.5% of 105 surgical procedures. The majority of procedures (89.5% were not accompanied by any post-surgical complications. Unsuccessful implantation in a single-step procedure (4.04% and transient facial nerve paralysis can be considered most frequent among our patients, whereas cochlear ossification (1.01% and transient ataxia (2.02% occurred rarely. Stimulation of the facial nerve (1.01%, intraoperative perilymph liquid gusher (1.01%, device failure and late infections (1.01% were recorded extremely rarely. Conclusion. Complications such as electrode extrusion, skin necrosis over the implant or meningitis, which is considered the most severe postoperative complication, have not been recorded at our Center since the very beginning. Absence of postoperative meningitis in patients treated at the Center can be attributed to timely pneumococcal vaccination of children.

  17. Balance Performance of Deaf Children With and Without Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Amir-Abbas Ebrahimi

    2016-12-01

    Full Text Available  The aim of this study was to compare the static and dynamic balance performance of deaf children with and without cochlear implants. This is a cross-sectional study of 145 school children, aged between 7 and 12 years comprising 85 children with congenital or early acquired bilateral profound sensorineural hearing loss (the hearing loss group and 60 normal hearing aged-matched control counterparts were assessed using the balance subtest of Bruininks-Oseretsky test of Motor Proficiency (BOTMP. The hearing loss group, 50 without cochlear implants (the non-implant group and 35 of them with unilateral cochlear implants (the implant group were recruited from schools for the deaf and normal hearing children (the control group randomly selected from two randomly selected elementary schools of Tehran city. The scores were analyzed using one-way ANOVA. The total score of deaf children especially the implant group were significantly lower than the control group P<0.001. The balance performance of the control group was better than the implant group in all of the items as well as the non-implant group except the fourth tested item (walking forward on a line (P<0.05. The balance score of the implant group was significantly lower than the non-implant group except for the third tested item (standing on the preferred leg on a balance beam with eyes closed. The findings suggested that deaf children, specifically those with cochlear implants are at risk for motor and balance deficits. Thus, vestibular and motor evaluations, as well as interventions to improve balance and motor skills, should be prioritized for this population.

  18. Diagnosis of functional nasolacrimal duct obstruction using dacryoscintigraphy

    International Nuclear Information System (INIS)

    Lim, Hyun Wook; Sohn, Hyung Sun; Kim, Euy Neyng; Chung, Yong An; Kim, Sung Hoon; Chung, Soo Kyo

    2000-01-01

    To evaluate the value of dacryoscintigraphy in the assessment of patients with a clinical diagnosis of functional nasolacrimal duct obstruction. Dacryoscintigraphy was performed in symptomatic 35 lacrimal drainage systems in 18 patients (age range: 37 ∼76,8 males, 10 females) that were patent on syringing. Abnormalities were detected with dacryoscintigraphy in 75.8% of systems. The positive scintigrams were subdivided into those demonstrating prelacrimal sac delay (31.8%), delay at the lacrimal sac/junction (40.9%), or delay within the duct (27%). Dacryoscintigraphy is noninvasive useful technique in the assessment of the functional nasolacrimal duct obstruction and very sensitive at detecting abnormalities in patients with lid laxity caused by senile change and facial nerve palsy

  19. Time course of collagen peak in bile duct-ligated rats.

    Science.gov (United States)

    Tarcin, Orhan; Basaranoglu, Metin; Tahan, Veysel; Tahan, Gülgün; Sücüllü, Ilker; Yilmaz, Nevin; Sood, Gagan; Snyder, Ned; Hilman, Gilbert; Celikel, Cigdem; Tözün, Nurdan

    2011-04-28

    One of the most useful experimental fibrogenesis models is the "bile duct-ligated rats". Our aim was to investigate the quantitative hepatic collagen content by two different methods during the different stages of hepatic fibrosis in bile duct-ligated rats on a weekly basis. We questioned whether the 1-wk or 4-wk bile duct-ligated model is suitable in animal fibrogenesis trials. Of the 53 male Wistar rats, 8 (Group 0) were used as a healthy control group. Bile duct ligation (BDL) had been performed in the rest. Bile duct-ligated rates were sacrificed 7 days later in group 1 (10 rats), 14 days later in group 2 (9 rats), 21 days later in group 3(9 rats) and 28 days later in group 4 (9 rats). Eight rats underwent sham-operation (Sham). Hepatic collagen measurements as well as serum levels of liver enzymes and function tests were all analysed. The peak level of collagen was observed biochemically and histomorphometricly at the end of third week (P fibrosis in bile duct-ligated rats is transient, i.e. reverses spontaneously after 3 weeks. This contrasts any situation in patients where hepatic fibrosis is progressive and irreversible as countless studies performed by many investigators in the same animal model.

  20. Long-term assessments after pancreaticoduodenectomy with pancreatic duct invagination anastomosis

    International Nuclear Information System (INIS)

    Fujino, Yasuhiro; Matsumoto, Ippei; Sakai, Tetsuya; Ajiki, Tetsuo; Ueda, Takashi; Kuroda, Yoshikazu; Suzuki, Yasuyuki

    2007-01-01

    The purpose of this cohort was to evaluate the long-term patency of the anastomosis and the remnant pancreatic functions. Fifty-six consecutive patients undergoing a pancreaticoduodenectomy with pancreatic duct invagination anastomosis were enrolled in this study. During the follow-up, changes in the remnant pancreatic duct size, pancreatic exocrine and endocrine functions, and nutritional status were monitored. No seriously activated pancreatic fistula, no hemorrhagic complications, no reoperations, and no in-hospital deaths were observed after surgery. A dilatation of remnant pancreatic duct was detected a total of 37 times (51%) during annual computed tomography (CT) evaluations. Pancreatic dysfunctions were observed in a considerable number of patients (exocrine 4/12, 9/14, and 8/16, endocrine 9/35, 8/27, and 4/16 at 1, 2, and 3 postoperative years, respectively). Functional declines in the remnant pancreas, duct dilatation, and a decrease in the body mass index were observed from the first year. However, these data did not progressively deteriorate thereafter, at least during the first 3 postoperative years. This study demonstrated a significant correlation between the duct dilatation and endocrine dysfunction. Our pancreatic duct invagination anastomosis resulted in somewhat limited long-term outcomes, although it did prevent serious complications in the short-term. (author)

  1. Sound Radiation from a Supersonic Jet Passing Through a Partially Open Exhaust Duct

    Science.gov (United States)

    Kandula, Max

    2011-01-01

    The radiation of sound from a perfectly expanded Mach 2.5 cold supersonic jet of 25.4 mm exit diameter flowing through a partially open rigid-walled duct with an upstream i-deflector has been studied experimentally. In the experiments, the nozzle is mounted vertically, with the nozzle exit plane at a height of 73 jet diameters above ground level. Relative to the nozzle exit plane (NEP), the location of the duct inlet is varied at 10, 5, and -1 jet diameters. Far-field sound pressure levels were obtained at 54 jet diameters above ground with the aid of acoustic sensors equally spaced around a circular arc of radius equal to 80 jet diameters from the jet axis. Data on the jet acoustic field for the partially open duct were obtained and compared with those with a free jet and with a closed duct. The results suggest that for the partially open duct the overall sound pressure level (OASPL) decreases as the distance between the NEP and the duct inlet plane decreases, while the opposite trend is observed for the closed duct. It is also concluded that the observed peak frequency in the partially open duct increases above the free jet value as the angle from the duct axis is increased, and as the duct inlet plane becomes closer to the NEP.

  2. Intraoperative Cochlear Implant Device Testing Utilizing an Automated Remote System: A Prospective Pilot Study.

    Science.gov (United States)

    Lohmann, Amanda R; Carlson, Matthew L; Sladen, Douglas P

    2018-03-01

    Intraoperative cochlear implant device testing provides valuable information regarding device integrity, electrode position, and may assist with determining initial stimulation settings. Manual intraoperative device testing during cochlear implantation requires the time and expertise of a trained audiologist. The purpose of the current study is to investigate the feasibility of using automated remote intraoperative cochlear implant reverse telemetry testing as an alternative to standard testing. Prospective pilot study evaluating intraoperative remote automated impedance and Automatic Neural Response Telemetry (AutoNRT) testing in 34 consecutive cochlear implant surgeries using the Intraoperative Remote Assistant (Cochlear Nucleus CR120). In all cases, remote intraoperative device testing was performed by trained operating room staff. A comparison was made to the "gold standard" of manual testing by an experienced cochlear implant audiologist. Electrode position and absence of tip fold-over was confirmed using plain film x-ray. Automated remote reverse telemetry testing was successfully completed in all patients. Intraoperative x-ray demonstrated normal electrode position without tip fold-over. Average impedance values were significantly higher using standard testing versus CR120 remote testing (standard mean 10.7 kΩ, SD 1.2 vs. CR120 mean 7.5 kΩ, SD 0.7, p automated testing with regard to the presence of open or short circuits along the array. There were, however, two cases in which standard testing identified an open circuit, when CR120 testing showed the circuit to be closed. Neural responses were successfully obtained in all patients using both systems. There was no difference in basal electrode responses (standard mean 195.0 μV, SD 14.10 vs. CR120 194.5 μV, SD 14.23; p = 0.7814); however, more favorable (lower μV amplitude) results were obtained with the remote automated system in the apical 10 electrodes (standard 185.4 μV, SD 11.69 vs. CR

  3. A speech processing study using an acoustic model of a multiple-channel cochlear implant

    Science.gov (United States)

    Xu, Ying

    1998-10-01

    A cochlear implant is an electronic device designed to provide sound information for adults and children who have bilateral profound hearing loss. The task of representing speech signals as electrical stimuli is central to the design and performance of cochlear implants. Studies have shown that the current speech- processing strategies provide significant benefits to cochlear implant users. However, the evaluation and development of speech-processing strategies have been complicated by hardware limitations and large variability in user performance. To alleviate these problems, an acoustic model of a cochlear implant with the SPEAK strategy is implemented in this study, in which a set of acoustic stimuli whose psychophysical characteristics are as close as possible to those produced by a cochlear implant are presented on normal-hearing subjects. To test the effectiveness and feasibility of this acoustic model, a psychophysical experiment was conducted to match the performance of a normal-hearing listener using model- processed signals to that of a cochlear implant user. Good agreement was found between an implanted patient and an age-matched normal-hearing subject in a dynamic signal discrimination experiment, indicating that this acoustic model is a reasonably good approximation of a cochlear implant with the SPEAK strategy. The acoustic model was then used to examine the potential of the SPEAK strategy in terms of its temporal and frequency encoding of speech. It was hypothesized that better temporal and frequency encoding of speech can be accomplished by higher stimulation rates and a larger number of activated channels. Vowel and consonant recognition tests were conducted on normal-hearing subjects using speech tokens processed by the acoustic model, with different combinations of stimulation rate and number of activated channels. The results showed that vowel recognition was best at 600 pps and 8 activated channels, but further increases in stimulation rate and

  4. Central transport and distribution of labelled glutamic and aspartic acids to the cochlear nucleus in cats

    International Nuclear Information System (INIS)

    Kane, E.S.

    1979-01-01

    Tritiated L-glutamic acid or L-aspartic acid was injected unilaterally into the cochleas of adult cats, and 4 h-7 days later the localization of label was studied by light-microscopic autoradiography in sections of the brain stem. Consistent differences in labelling after glutamate and after aspartate suggest differences in their uptake, metabolic conversion and/or transport to the cochlear nucleus by cochlear fibers. The morphological differences shown here agree with the distribution of those two amino acids in the cat cochlear nucleus as shown by microchemical analyses. (author)

  5. Seismic assessment of the Pickering pressure relief duct

    International Nuclear Information System (INIS)

    Ghobarah, A.

    1995-05-01

    The objectives of the study are to examine the structural response of the Pickering pressure relief duct when subjected to earthquake ground motion and to estimate the seismic withstand capacity of various components of the structural system on the basis of performance criteria consistent with the safety function of the duct. (author). 24 refs., 16 tabs., 31 figs

  6. Spiral Form of the Human Cochlea Results from Spatial Constraints.

    Science.gov (United States)

    Pietsch, M; Aguirre Dávila, L; Erfurt, P; Avci, E; Lenarz, T; Kral, A

    2017-08-08

    The human inner ear has an intricate spiral shape often compared to shells of mollusks, particularly to the nautilus shell. It has inspired many functional hearing theories. The reasons for this complex geometry remain unresolved. We digitized 138 human cochleae at microscopic resolution and observed an astonishing interindividual variability in the shape. A 3D analytical cochlear model was developed that fits the analyzed data with high precision. The cochlear geometry neither matched a proposed function, namely sound focusing similar to a whispering gallery, nor did it have the form of a nautilus. Instead, the innate cochlear blueprint and its actual ontogenetic variants were determined by spatial constraints and resulted from an efficient packing of the cochlear duct within the petrous bone. The analytical model predicts well the individual 3D cochlear geometry from few clinical measures and represents a clinical tool for an individualized approach to neurosensory restoration with cochlear implants.

  7. Optimized Matching Lift Unit Transmission Ratio of Engine Driven Ducted Fan

    Directory of Open Access Journals (Sweden)

    Xiao Senlin

    2018-01-01

    Full Text Available As a kind of VTOL technology, ducted fan is not only used by many kinds of aircrafts, but also one of the trends of the future aircraft lift system, and attracts more and more attention. For an engine driven ducted fan lift unit, involving the engine and ducted fan matching problem, the form of transmission and transmission ratio are the key design parameters. In order to design and develop a ducted fan aircraft reasonably, a thrust test platform was set up to connect the engine with the ducted fan through the belt driving. The matching relationship between the engine and the transmission system was experimentally studied and the optimal transmission ratio was determined. The results showed that the optimal transmission ratio for the engine 1 is 2.2:1, and for the engine 2, the optimal transmission ratio should be 2.95:1 based on the current ducted and movable blade aerofoil design. At this time, the lift will exceed 130 kg•f, meeting the aircraft's original design requirements.

  8. Carcinosarcoma of the Extrahepatic Bile Duct Presenting with Stone-like Radiological Findings.

    Science.gov (United States)

    Kumei, Shinsuke; Onishi, Yutaka; Ogura, Takeshi; Kusumoto, Chosei; Matsuno, Yasuko; Nishigami, Takashi; Maeda, Mitsuo; Harada, Masaru

    2015-01-01

    A 73-year-old woman was referred to our hospital due to epigastralgia and jaundice. The radiological findings showed a stone-like tumor in the extrahepatic bile duct. The patient was initially thought to have adenocarcinoma of the bile duct based on the findings of a pathological examination of the bile duct biopsy specimen and underwent pancreaticoduodenectomy; the final diagnosis of the lesion was so-called carcinosarcoma of the extrahepatic bile duct. She died of liver metastasis six months after the surgery. This case suggests that surgical resection is not adequate for achieving a radical cure, and the optimal treatment for extrahepatic bile duct carcinosarcoma should be established immediately.

  9. Active noise control in a duct to cancel broadband noise

    Science.gov (United States)

    Chen, Kuan-Chun; Chang, Cheng-Yuan; Kuo, Sen M.

    2017-09-01

    The paper presents cancelling duct noises by using the active noise control (ANC) techniques. We use the single channel feed forward algorithm with feedback neutralization to realize ANC. Several kinds of ducts noises including tonal noises, sweep tonal signals, and white noise had investigated. Experimental results show that the proposed ANC system can cancel these noises in a PVC duct very well. The noise reduction of white noise can be up to 20 dB.

  10. Hearing loss patterns after cochlear implantation via the round window in an animal model.

    Science.gov (United States)

    Attias, Joseph; Hod, Roy; Raveh, Eyal; Mizrachi, Aviram; Avraham, Karen B; Lenz, Danielle R; Nageris, Ben I

    2016-01-01

    The mechanism and the type of hearing loss induced by cochlear implants are mostly unknown. Therefore, this study evaluated the impact and type of hearing loss induced by each stage of cochlear implantation surgery in an animal model. Original basic research animal study. The study was conducted in a tertiary, university-affiliated medical center in accordance with the guidelines of the Institutional Animal Care and Use Committee. Cochlear implant electrode array was inserted via the round window membrane in 17 ears of 9 adult-size fat sand rats. In 7 ears of 5 additional animals round window incision only was performed, followed by patching with a small piece of periosteum (control). Hearing thresholds to air (AC) and bone conduction (BC), clicks, 1 kHz and 6 kHz tone bursts were measured by auditory brainstem evoked potential, before, during each stage of surgery and one week post-operatively. In addition, inner ear histology was performed. The degree of hearing loss increased significantly from baseline throughout the stages of cochlear implantation surgery and up to one week after (plosses were found for 1-kHz and 6-kHz frequencies. The hearing loss was not associated with significant changes in inner ear histology. Hearing loss following cochlear implantation in normal hearing animals is progressive and of mixed type, but mainly conductive. Changes in the inner-ear mechanism are most likely responsible for the conductive hearing loss. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Temporal and spectral contributions to musical instrument identification and discrimination among cochlear implant users

    Institute of Scientific and Technical Information of China (English)

    Sandra M. Prentiss; David R. Friedland; Tanner Fullmer; Alison Crane; Timothy Stoddard; Christina L. Runge

    2016-01-01

    Objective:To investigate the contributions of envelope and fine-structure to the perception of timbre by cochlear implant (CI) users as compared to normal hearing (NH) lis-teners. Methods: This was a prospective cohort comparison study. Normal hearing and cochlear implant patients were tested. Three experiments were performed in sound field using musical notes altered to affect the characteristic pitch of an instrument and the acoustic envelope. Experiment 1 assessed the ability to identify the instrument playing each note, while experi-ments 2 and 3 assessed the ability to discriminate the different stimuli. Results:Normal hearing subjects performed better than CI subjects in all instrument identifi-cation tasks, reaching statistical significance for 4 of 5 stimulus conditions. Within the CI pop-ulation, acoustic envelope modifications did not significantly affect instrument identification or discrimination. With envelope and pitch cues removed, fine structure discrimination perfor-mance was similar between normal hearing and CI users for the majority of conditions, but some specific instrument comparisons were significantly more challenging for CI users. Conclusions:Cochlear implant users perform significantly worse than normal hearing listeners on tasks of instrument identification. However, cochlear implant listeners can discriminate differences in envelope and some fine structure components of musical instrument sounds as well as normal hearing listeners. The results indicated that certain fine structure cues are important for cochlear implant users to make discrimination judgments, and therefore may affect interpretation toward associating with a specific instrument for identification.

  12. Across-frequency combination of interaural time difference in bilateral cochlear implant listeners

    Directory of Open Access Journals (Sweden)

    Antje eIhlefeld

    2014-03-01

    Full Text Available The current study examined how cochlear implant (CI listeners combine temporally interleaved envelope-ITD information across two sites of stimulation. When two cochlear sites jointly transmit ITD information, one possibility is that CI listeners can extract the most reliable ITD cues available. As a result, ITD sensitivity would be sustained or enhanced compared to single-site stimulation. Alternatively, mutual interference across multiple sites of ITD stimulation could worsen dual-site performance compared to listening to the better of two electrode pairs. Two experiments used direct stimulation to examine how CI users can integrate ITDs across two pairs of electrodes. Experiment 1 tested ITD discrimination for two stimulation sites using 100-Hz sinusoidally modulated 1000-pps-carrier pulse trains. Experiment 2 used the same stimuli ramped with 100 ms windows, as a control condition with minimized onset cues. For all stimuli, performance improved monotonically with increasing modulation depth. Results show that when CI listeners are stimulated with electrode pairs at two cochlear sites, sensitivity to ITDs was similar to that seen when only the electrode pair with better sensitivity was activated. None of the listeners showed a decrement in performance from the worse electrode pair. This could be achieved either by listening to the better electrode pair or by truly integrating the information across cochlear sites.

  13. Effect of age at cochlear implantation on auditory and speech development of children with auditory neuropathy spectrum disorder.

    Science.gov (United States)

    Liu, Yuying; Dong, Ruijuan; Li, Yuling; Xu, Tianqiu; Li, Yongxin; Chen, Xueqing; Gong, Shusheng

    2014-12-01

    To evaluate the auditory and speech abilities in children with auditory neuropathy spectrum disorder (ANSD) after cochlear implantation (CI) and determine the role of age at implantation. Ten children participated in this retrospective case series study. All children had evidence of ANSD. All subjects had no cochlear nerve deficiency on magnetic resonance imaging and had used the cochlear implants for a period of 12-84 months. We divided our children into two groups: children who underwent implantation before 24 months of age and children who underwent implantation after 24 months of age. Their auditory and speech abilities were evaluated using the following: behavioral audiometry, the Categories of Auditory Performance (CAP), the Meaningful Auditory Integration Scale (MAIS), the Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS), the Standard-Chinese version of the Monosyllabic Lexical Neighborhood Test (LNT), the Multisyllabic Lexical Neighborhood Test (MLNT), the Speech Intelligibility Rating (SIR) and the Meaningful Use of Speech Scale (MUSS). All children showed progress in their auditory and language abilities. The 4-frequency average hearing level (HL) (500Hz, 1000Hz, 2000Hz and 4000Hz) of aided hearing thresholds ranged from 17.5 to 57.5dB HL. All children developed time-related auditory perception and speech skills. Scores of children with ANSD who received cochlear implants before 24 months tended to be better than those of children who received cochlear implants after 24 months. Seven children completed the Mandarin Lexical Neighborhood Test. Approximately half of the children showed improved open-set speech recognition. Cochlear implantation is helpful for children with ANSD and may be a good optional treatment for many ANSD children. In addition, children with ANSD fitted with cochlear implants before 24 months tended to acquire auditory and speech skills better than children fitted with cochlear implants after 24 months. Copyright © 2014

  14. Comparison of Persian Simple Vowels Production in Cochlear Implanted Children Based on Implantation Age

    Directory of Open Access Journals (Sweden)

    Peiman Zamani

    2008-07-01

    Full Text Available Objective: Age at implantation is one of the most important factors in improving speech and language skills in children with cochlear implants. Moreover, good vowel articulation is very important in the speech. So, the purpose of this research was to determine whether age at cochlear implantation influences the production of Persian simple vowels when cochlear implantation is undertaken below the age of 2 years as compared with cochlear implantation later in life. Materials & Methods: This research was a comparative and cross-sectional study. Based on inclusive and exclusive criteria (i.e., have physical and mental health, monolingual or bilingual, have 9±1 months post-surgery rehabilitation, no hearing handicapped parents and no medical problems history, 140 children who cochlear implanted in Amir-Alam and Hazrate Rasool hospital of Tehran city were selected by convenient sampling and assigned to two groups, children implanted under the age of 2 years and those implanted above the age of 2 years Also 238 normally hearing children were selected for control group by randomized sampling. The first and second formant frequency (F1 & F2 of the Persian simple vowels /i, e, æ, a, o, u/ were evaluated by the version of 1.2 of SFSwin software. Data were analyzed by Independent T test. Results: The findings indicated that there were significant differences between two groups in the mean of F2/i/ (P=0.046, F1/e/ (P=0.011, F2/e/ (P=0.005, F2/æ/ (P=0.039, F2/a/ (P=0.012, F2/o/ (P=0.012 and F2/u/ (P=0.006, but there was no significant difference between then in the mean of F1/i/, F1/æ/, F2/a/, F1/o/, F1/u/ (P>0.05. According to these results, no significant difference was seen between normal group and children who received their cochlear implants under the age of 2 years in the mean of variables (P>0.05. Conclusion: Observing significant differences in the quality of the production of Persian simple vowels between children implanted under the age of 2

  15. Evidence of echoic memory with a multichannel cochlear prosthesis.

    Science.gov (United States)

    Jerger, S; Watkins, M J

    1988-10-01

    Short-term memory was examined in a subject with a multichannel cochlear prosthesis. Serial recall for lists of digits revealed what are widely regarded as the principal hallmarks of echoic memory, namely the recency effect and the suffix effect. Thus, probability of recall increased for the last one or two digits, except when a nominally irrelevant but spoken item was appended to the to-be-remembered list. It appears, therefore, that a multichannel cochlear implant can give rise to not only the perception of, but also an echoic memory for, speech. As with normal subjects, the suffix effect did not occur with a nonspeech suffix, implying that the echoic memory from the prosthesis shows normal sensitivity to the distinction between speech and nonspeech.

  16. Cochlear Implantation in Patients with Neurofibromatosis Type 2 and Patients with Vestibular Schwannoma in the Only Hearing Ear

    Directory of Open Access Journals (Sweden)

    Erika Celis-Aguilar

    2012-01-01

    Full Text Available Cochlear implants are a new surgical option in the hearing rehabilitation of patients with neurofibromatosis type 2 (NF2 and patients with vestibular schwannoma (VS in the only hearing ear. Auditory brainstem implant (ABI has been the standard surgical treatment for these patients. We performed a literature review of patients with NF2 and patients with VS in the only hearing ear. Cochlear implantation (CI provided some auditory benefit in all patients. Preservation of cochlear nerve integrity is crucial after VS resection. Results ranged from environmental sound awareness to excellent benefit with telephone use. Promontory stimulation is recommended although not crucial. MRI can be performed safely in cochlear implanted patients.

  17. Muellerian duct cyst as a cause of acute infantile-onset epididymitis

    Energy Technology Data Exchange (ETDEWEB)

    Donkol, Ragab H.; Moghazy, Khaled [Gulf Specialist Hospital, Department of Radiology, P.O. Box 1444, Qatif (Saudi Arabia); Monib, Sherif [Gulf Specialist Hospital, Department of General Surgery, Qatif (Saudi Arabia)

    2006-11-15

    Muellerian duct cyst is a congenital anomaly that originates from remnants of the muellerian duct that usually regresses in utero. It is most commonly detected in adult males during the third and fourth decades of life. Muellerian duct cyst is rarely reported in infants less than 1 year of age, in whom diagnosis is difficult because of immaturity of the genital tract. In this case report, we describe the sonographic and CT appearance of a large intrapelvic muellerian duct cyst presenting with acute epididymitis in a 9-month-old infant. The embryological basis, imaging findings and relation to epididymitis are discussed. (orig.)

  18. Muellerian duct cyst as a cause of acute infantile-onset epididymitis

    International Nuclear Information System (INIS)

    Donkol, Ragab H.; Moghazy, Khaled; Monib, Sherif

    2006-01-01

    Muellerian duct cyst is a congenital anomaly that originates from remnants of the muellerian duct that usually regresses in utero. It is most commonly detected in adult males during the third and fourth decades of life. Muellerian duct cyst is rarely reported in infants less than 1 year of age, in whom diagnosis is difficult because of immaturity of the genital tract. In this case report, we describe the sonographic and CT appearance of a large intrapelvic muellerian duct cyst presenting with acute epididymitis in a 9-month-old infant. The embryological basis, imaging findings and relation to epididymitis are discussed. (orig.)

  19. Libyan cochlear implant programme: achievements, difficulties, and ...

    African Journals Online (AJOL)

    Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI100 devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) ...

  20. Acoustic power balance in lined ducts

    Science.gov (United States)

    Eversman, W.

    1979-01-01

    It is shown that the two common definitions of acoustic energy density and intensity in uniform unlined ducts carrying uniform flow are compatible to the extent that both energy densities can be used in an appropriate variational principle to derive the convected wave equation. When the duct walls are lined both energy densities must be modified to account for the wall energy density. This results in a new energy conservation equation which utilizes a modified definition of axial power and accounts for wall dissipation. Computations in specific cases demonstrate the validity of the modified acoustic energy relation.

  1. Hemodynamic characterization of chronic bile duct-ligated rats: effect of pentobarbital sodium

    International Nuclear Information System (INIS)

    Lee, S.S.; Girod, C.; Braillon, A.; Hadengue, A.; Lebrec, D.

    1986-01-01

    Systemic and splanchnic hemodynamics of the chronic bile duct-ligated rat were characterized by radioactive microspheres. Conscious and pentobarbital sodium-anesthetized, bile duct-ligated and sham-operated rats had cardiac output and regional organ blood flows determined. The conscious bile duct-ligated rat compared with the sham-operated showed a hyperdynamic circulation with an increased cardiac output and portal tributary blood flow. Pentobarbital sodium anesthesia induced marked hemodynamic changes in both sham-operated and bile duct-ligated rats. The latter group was especially sensitive to its effects; thus, comparison of cardiac output and portal tributary blood flow between anesthetized bile duct-ligated and sham-operated rats showed no significant differences. The authors conclude that the rat with cirrhosis due to chronic bile duct ligation is an excellent model for hemodynamic investigations but should be studied in the conscious state, since pentobarbital sodium anesthesia eliminated the hyperdynamic circulation

  2. BACTERIOLOGICAL INVESTIGATION ON Fasciola hepatica AND CATTLE BILIARY DUCTS

    Directory of Open Access Journals (Sweden)

    A. Panebianco

    2009-03-01

    Full Text Available The aim of this work was to investigate the occurrence of bacteria in Fasciola hepatica and into cattle biliary ducts containing the parasite. A total of 24 liver and 58 F. hepatica samples were analysed. In all biliary ducts and in 62,06% of parasite Enterobacteriaceae were isolated. The bacterial specie more frequently isolated from parasite were Citrobacter freundii (34%, Proteus mirabilis (18%, Providencia rettgeri (12%, Staphylococcus spp. (18%, Enterobacter spp. (12%. There doesn’t appear to be a correlation between bacterial specie from parasite and ducts. The Authors conclude with some related inspective consideration.

  3. Preoperative intraluminal irradiation of the extrahepatic bile duct tumor

    International Nuclear Information System (INIS)

    Kamada, Tadashi; Tsujii, Hirohiko; Arimoto, Takuro; Irie, Goro.

    1991-01-01

    From 1984 through 1986, six patients with extrahepatic bile duct tumor were treated preoperatively with intraluminal irradiation of the bile duct. There were no unresectable cases and pathological examination of the surgical specimens showed moderate to remarkable tumor regression in all cases. Postoperative biliary tract hemorrhage occurred in 2 of 3 patients who received 60 Gy at a point 7.5 mm from the center of the source. With accurate preoperative diagnosis of the tumor extent and careful setting of the target area of intraluminal irradiation, improved local tumor control of extrahepatic bile duct tumor can be expected with this method. (author)

  4. Tolerance of bile duct to intraoperative irradiation

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Tepper, J.; Travis, E.L.

    1982-01-01

    In order to determine the effects of intraoperative radiation therapy of the bile duct and surrounding tissues, seven adult dogs were subjected to laparotomy and intraoperative irradiation with 11 MeV electrons. Two animals were treated at each dose level of 2000, 3000, and 4500 rads. A single dog which received a laparotomy and sham irradiation served as a control. The irradiation field consisted of a 5 cm diameter circle encompassing the extrahepatic bile duct, portal vein, hepatic artery, and lateral duodenal wall. The animals were followed clinically for mor than 18 months after treatment, and autopsies were performed on dogs that died to assess radiation-induced complications or tissue damage. All dogs developed fibrosis and mural thickening of the common duct, which appeared by 6 weeks following irradiation and which was dose-related, being mild at low doses and more severe at high doses. Hepatic changes were seen as early as 6 weeks after irradiation, consisting of periportal inflammation and fibrosis. The hepatic changes appeared earliest at the highest doses. Frank biliary cirrhosis eventually developed at all dose levels. Duodenal fibrosis appeared in the irradiation portal, being most severe at the highest doses and in some animals resulting in duodenal obstruction. No changes were observed in irradiated portions of portal vein and hepatic artery at any dose level. It was concluded that intraoperative radiation therapy delivered to the region of the common duct leads to ductal fibrosis, partial biliary obstruction with secondary hepatic changes, and duodenal fibrosis if bowel wall is included in the field. Clinical use of intraoperative radiation therapy to the bile duct in humans may require routine use of biliary and duodenal bypass to prevent obstructive complications

  5. Practical use of CFD for air conditioning duct and defroster designing; Kucho duct defroster no CFD sekkei katsuyo

    Energy Technology Data Exchange (ETDEWEB)

    Okumura, K [Daihatsu Motor Co. Ltd., Osaka (Japan)

    1997-10-01

    The automobile industry have made effort to shorten the development period. Recently CFD (Computational Fluid Dynamics) on initial design stage becomes use for improvement of development efficiency. Although the practical guidepost (computed examples) for air conditioning duct and defroster are a little reported. This report presents how to optimize and standardize the calculational methods, calculational grid, boundary conditions for air conditioning duct and defroster nozzle in the practical use. Also we tried the discontinuous interface grid and the solution adaptive method. 2 refs., 17 figs.

  6. Cochlear implant: Speech and language development in deaf and hard of hearing children following implantation

    Directory of Open Access Journals (Sweden)

    Ostojić Sanja

    2011-01-01

    Full Text Available Bacground/Aim. Almost 200 cochlear implantations were done in the four centers (two in Belgrade, per one in Novi Sad and Niš in Serbia from 2002 to 2009. Less than 10% of implantees were postlingually deaf adults. The vast majority, i.e. 90% were pre- and perilingually profoundly deaf children. The aim of this study was to assess the influence of improved auditory perception due to cochlear implantation on comprehension of abstract words in children as compared with hearing impaired children with conventional hearing aids and normal hearing children. Methods. Thirty children were enrolled in this study: 20 hearing impaired and 10 normal hearing. The vocabulary test was used. Results. The overall results for the whole test (100 words showed a significant difference in favor of the normal hearing as compared with hearing impaired children. The normal hearing children successfully described or defined 77.93% of a total of 100 words. Success rate for the cochlear implanted children was 26.87% and for the hearing impaired children with conventional hearing aids 20.32%. Conclusion. Testing for abstract words showed a statistically significant difference between the cochlear implanted and the hearing impaired children with hearing aids (Mann- Whitney U-test, p = 0.019 implying considerable advantage of cochlear implants over hearing aids regarding successful speech development in prelingually deaf children.

  7. Breaking the sound barrier: exploring parents' decision-making process of cochlear implants for their children.

    Science.gov (United States)

    Chang, Pamara F

    2017-08-01

    To understand the dynamic experiences of parents undergoing the decision-making process regarding cochlear implants for their child(ren). Thirty-three parents of d/Deaf children participated in semi-structured interviews. Interviews were digitally recorded, transcribed, and coded using iterative and thematic coding. The results from this study reveal four salient topics related to parents' decision-making process regarding cochlear implantation: 1) factors parents considered when making the decision to get the cochlear implant for their child (e.g., desire to acculturate child into one community), 2) the extent to which parents' communities influence their decision-making (e.g., norms), 3) information sources parents seek and value when decision-making (e.g., parents value other parent's experiences the most compared to medical or online sources), and 4) personal experiences with stigma affecting their decision to not get the cochlear implant for their child. This study provides insights into values and perspectives that can be utilized to improve informed decision-making, when making risky medical decisions with long-term implications. With thorough information provisions, delineation of addressing parents' concerns and encompassing all aspects of the decision (i.e., medical, social and cultural), health professional teams could reduce the uncertainty and anxiety for parents in this decision-making process for cochlear implantation. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Risk of pancreatitis after pancreatic duct guidewire placement during endoscopic retrograde cholangiopancreatography.

    Directory of Open Access Journals (Sweden)

    Yuki Ishikawa-Kakiya

    Full Text Available Advanced techniques have been developed to overcome difficult cannulation cases in endoscopic retrograde cholangiopancreatography (ERCP. Pancreatic duct guidewire placement method (PGW is performed in difficult cannulation cases; it is possible that it places patients at risk of post-ERCP pancreatitis (PEP. The mechanism of PEP is still unclear, but pancreatic duct pressure and injury of pancreatic duct are known causes of PEP. Therefore, we hypothesized a relationship between pancreatic duct diameter and PEP and predicted that PGW would increase the risk of PEP in patients with non-dilated pancreatic ducts. This study aimed to investigate whether PGW increased the risk of PEP in patients with pancreatic duct diameter ≤ 3 mm.We analyzed 332 patients with pancreatic duct ≤ 3 mm who performed first time ERCP session. The primary endpoint was the rate of adverse event of PEP. We evaluated the risk of PEP in patients who had undergone PGW compared to those who had not, using the inverse probability of treatment weighting (IPTW analysis.PGW was found to be an independent risk factor for PEP by univariate analysis (odds ratio [OR], 2.45; 95% confidence interval [CI], 1.12-5.38; p = 0.03 after IPTW in patients with pancreatic duct diameter ≤ 3 mm. Adjusted for all covariates, PGW remained an independent risk factor for PEP (OR, 3.12; 95% CI, 1.33-7.33; p = 0.01.Our results indicate that PGW in patients with pancreatic duct diameter ≤ 3 mm increases the risk of PEP.

  9. Mucocele of the cystic duct remnant after orthotopic liver transplant: a problem revisited.

    Science.gov (United States)

    Chatterjee, Suvadip; Das, Debasish; Hudson, Mark; Bassendine, Margaret Fiona; Scott, John; Oppong, Kofi Ernest; Sen, Gourab; French, Jeremy J

    2011-06-01

    Mucocele of the cystic duct remnant is an uncommon hepatobiliary complication of a liver transplant. Current practice usually involves either excising the cystic duct, or incorporating the distal end of the transected cystic duct into the suture line of the biliary anastomosis to ensure drainage. We report a patient who developed cystic duct remnant mucocele after the latter approach was adopted. We believe that this is likely related to delayed anastomotic stricturing, which prevented draining from the remnant cystic duct. We also discuss the incidence, pathology, investigations, and treatment of this condition.

  10. Different Perception of Musical Stimuli in Patients with Monolateral and Bilateral Cochlear Implants

    Science.gov (United States)

    Maglione, Anton Giulio; Leone, Carlo Antonio; Grassia, Rosa; Mosca, Franco; Colosimo, Alfredo; Malerba, Paolo

    2014-01-01

    The aim of the present study is to measure the perceived pleasantness during the observation of a musical video clip in a group of cochlear implanted adult patients when compared to a group of normal hearing subjects. This comparison was performed by using the imbalance of the EEG power spectra in alpha band over frontal areas as a metric for the perceived pleasantness. Subjects were asked to watch a musical video clip in three different experimental conditions: with the original audio included (Norm), with a distorted version of the audio (Dist), and without the audio (Mute). The frontal EEG imbalance between the estimated power spectra for the left and right prefrontal areas has been calculated to investigate the differences among the two populations. Results suggested that the perceived pleasantness of the musical video clip in the normal hearing population and in the bilateral cochlear implanted populations has similar range of variation across the different stimulations (Norm, Dist, and Mute), when compared to the range of variation of video clip's pleasantness for the monolateral cochlear implanted population. A similarity exists in the trends of the perceived pleasantness across the different experimental conditions in the mono- and bilaterally cochlear implanted patients. PMID:25180046

  11. Educational, employment, and social participation of young adult graduates from the paediatric Southern Cochlear Implant Programme, New Zealand.

    Science.gov (United States)

    Goh, Terence; Bird, Philip; Pearson, John; Mustard, Jill

    2016-01-01

    The purpose of this study is to observe the education and vocational achievements and social participation of cochlear implant recipients as they graduate from a paediatric cochlear implant programme and identify any significant associations that might exist. This study identified 56 patients from the Southern Cochlear Implant Programme (SCIP) who received cochlear implants before the age of 19 (paediatric) and are now over the age of 19 (adult). A questionnaire investigated their education, employment, and identity with the hearing and deaf communities. Also included were the satisfaction with life scale and Hearing Participation Scale (HPS). Subjects ranged in age from 19 to 32. Twenty-six patients responded to the questionnaire, including one non-user. Twenty identified strongly or very strongly with the hearing community. There was weak evidence of a linear association between strong identity with the hearing community and a higher HPS score. No other statistically significant associations were detected. Interestingly, 12 out of 26 participants found employment through family. Positive outcome trends in education and employment were seen in this study although no statistical significance was achieved. There is a strong bias for those who use their cochlear implants regularly, and there are no data available for those who do not use their cochlear implants for comparison as only one non-user completed the survey, despite efforts to include this group. This study shows that there is perceived benefit in implantation for patients who use it regularly but further research is needed with a more diverse group of cochlear implant recipients.

  12. Time course of collagen peak in bile duct-ligated rats

    Directory of Open Access Journals (Sweden)

    Snyder Ned

    2011-04-01

    Full Text Available Abstract Background One of the most useful experimental fibrogenesis models is the "bile duct-ligated rats". Our aim was to investigate the quantitative hepatic collagen content by two different methods during the different stages of hepatic fibrosis in bile duct-ligated rats on a weekly basis. We questioned whether the 1-wk or 4-wk bile duct-ligated model is suitable in animal fibrogenesis trials. Methods Of the 53 male Wistar rats, 8 (Group 0 were used as a healthy control group. Bile duct ligation (BDL had been performed in the rest. Bile duct-ligated rates were sacrificed 7 days later in group 1 (10 rats, 14 days later in group 2 (9 rats, 21 days later in group 3(9 rats and 28 days later in group 4 (9 rats. Eight rats underwent sham-operation (Sham. Hepatic collagen measurements as well as serum levels of liver enzymes and function tests were all analysed. Results The peak level of collagen was observed biochemically and histomorphometricly at the end of third week (P Conclusion We have shown that fibrosis in bile duct-ligated rats is transient, i.e. reverses spontaneously after 3 weeks. This contrasts any situation in patients where hepatic fibrosis is progressive and irreversible as countless studies performed by many investigators in the same animal model.

  13. Surgical management of Stenson's duct injury using epidural catheter

    African Journals Online (AJOL)

    2012-07-05

    Jul 5, 2012 ... Successful management of parotid duct injury depends on early diagnosis and appropriate intervention, failing of ... to diagnose and manage the parotid duct injuries using an “epidural catheter” which is often used for inducing spinal anesthesia. .... Water-soluble contrast media have a definite advantage.

  14. Positioning of supporting-cable ducts in a prestressed concrete bridge

    International Nuclear Information System (INIS)

    Roetzer, H.

    1981-01-01

    Before inserting the supporting cables positioning of cable ducts in prestressed concrete bridges can be performed with the aid of radiation sources hauled through the ducts and localized by means of radiation monitors

  15. Environmental Sound Training in Cochlear Implant Users

    Science.gov (United States)

    Shafiro, Valeriy; Sheft, Stanley; Kuvadia, Sejal; Gygi, Brian

    2015-01-01

    Purpose: The study investigated the effect of a short computer-based environmental sound training regimen on the perception of environmental sounds and speech in experienced cochlear implant (CI) patients. Method: Fourteen CI patients with the average of 5 years of CI experience participated. The protocol consisted of 2 pretests, 1 week apart,…

  16. Simultaneous Communication and Cochlear Implants in the Classroom?

    NARCIS (Netherlands)

    Blom, H.C.; Marschark, M.

    2015-01-01

    This study was designed to evaluate the potential of simultaneous communication (sign and speech together) to support classroom learning by college students who use cochlear implants (CIs). Metacognitive awareness of learning also was evaluated. A within-subjects design involving 40 implant users

  17. An evaluation of damping ratios for HVAC duct systems using vibration test data

    International Nuclear Information System (INIS)

    Gunyasu, K.; Horimizu, Y.; Kawakami, A.; Iokibe, H.; Yamazaki, T.

    1988-01-01

    The function of Heating Ventilating Air Conditioning (HVAC) systems must be maintained including HVAC duct systems to keep the operation of safety-related equipment in nuclear power plants during earthquake excitations. Therefore, it is important to carry out seismic design for HVAC duct systems. In the previous aseismic design for HVAC duct systems, the 0.5% damping ratio has been used in Japan. In recent years, vibration tests, held on actual duct systems in nuclear power plants and mockup duct systems were performed in order to investigate damping ratios for HVAC duct systems. Based on the results, it was confirmed that the damping ratio for HVAC duct systems, evaluated from these tests, were much greater than the 0.5% damping ratio used in the previous aseismic design of Japan. The new damping ratio in aseismic design was proposed to be 2.5%. The present paper describes the results of the above mentioned investigation

  18. CT differentiation of mucin-producing cystic neoplasms of the liver from solitary bile duct cysts.

    Science.gov (United States)

    Kim, Hyoung Jung; Yu, Eun Sil; Byun, Jae Ho; Hong, Seung-Mo; Kim, Kyoung Won; Lee, Jong Seok; Kim, So Yeon

    2014-01-01

    The purpose of this study was to identify the CT features required for differentiating mucin-producing cystic neoplasms of the liver (mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct) from solitary bile duct cysts. CT images of pathologically confirmed mucinous cystic neoplasms (n = 15), cyst-forming intraductal papillary neoplasms of the bile duct (n = 16), and solitary bile duct cysts (n = 31) were reviewed. Analysis of the CT findings included shape, presence of septa, location of septa (peripheral vs central), thickness of septa (thin vs thick), mosaic pattern, mural nodules, intracystic debris, calcification, upstream bile duct dilatation, downstream bile duct dilatation, and communication between a cystic lesion and the bile duct. The maximum size of a cystic lesion and the maximum size of the largest mural nodule were measured. The presence of septa, central septa, mural nodules, upstream bile duct dilatation, and downstream bile duct dilatation were found to be significant CT findings for differentiating mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct from solitary bile duct cysts (p bile duct were 87% (27 of 31) and 87% (27 of 31), respectively. When two of these five criteria were used in combination, the sensitivity and specificity for diagnosing mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct were 87% (27 of 31) and 87% (27 of 31), respectively [corrected]. With the use of specific CT criteria, mucin-producing cystic neoplasms of the liver can be differentiated from solitary bile duct cysts with a high degree of accuracy.

  19. Heat Transfer Computations of Internal Duct Flows With Combined Hydraulic and Thermal Developing Length

    Science.gov (United States)

    Wang, C. R.; Towne, C. E.; Hippensteele, S. A.; Poinsatte, P. E.

    1997-01-01

    This study investigated the Navier-Stokes computations of the surface heat transfer coefficients of a transition duct flow. A transition duct from an axisymmetric cross section to a non-axisymmetric cross section, is usually used to connect the turbine exit to the nozzle. As the gas turbine inlet temperature increases, the transition duct is subjected to the high temperature at the gas turbine exit. The transition duct flow has combined development of hydraulic and thermal entry length. The design of the transition duct required accurate surface heat transfer coefficients. The Navier-Stokes computational method could be used to predict the surface heat transfer coefficients of a transition duct flow. The Proteus three-dimensional Navier-Stokes numerical computational code was used in this study. The code was first studied for the computations of the turbulent developing flow properties within a circular duct and a square duct. The code was then used to compute the turbulent flow properties of a transition duct flow. The computational results of the surface pressure, the skin friction factor, and the surface heat transfer coefficient were described and compared with their values obtained from theoretical analyses or experiments. The comparison showed that the Navier-Stokes computation could predict approximately the surface heat transfer coefficients of a transition duct flow.

  20. Excluded segmental duct bile leakage: the case for bilio-enteric anastomosis.

    Science.gov (United States)

    Patrono, Damiano; Tandoi, Francesco; Romagnoli, Renato; Salizzoni, Mauro

    2014-06-01

    Excluded segmental duct bile leak is the rarest type of post-hepatectomy bile leak and presents unique diagnostic and management features. Classical management strategies invariably entail a significant loss of functioning hepatic parenchyma. The aim of this study is to report a new liver-sparing technique to handle excluded segmental duct bile leakage. Two cases of excluded segmental duct bile leak occurring after major hepatic resection were managed by a Roux-en-Y hepatico-jejunostomy on the excluded segmental duct, avoiding the sacrifice of the liver parenchyma origin of the fistula. In both cases, classical management strategies would have led to the functional loss of roughly 50 % of the liver remnant. Diagnostic and management implications are thoroughly discussed. Both cases had an uneventful postoperative course. The timing of repair was associated with a different outcome: the patient who underwent surgical repair in the acute phase developed no long-term complications, whereas the patient who underwent delayed repair developed a late stenosis requiring percutaneous dilatation. Roux-en-Y hepatico-jejunostomy on the excluded bile duct is a valuable technique in selected cases of excluded segmental duct bile leakage.