WorldWideScience

Sample records for nonmetallic cartridge case

  1. Magazine Influence on Cartridge Case Ejection Patterns with Glock Pistols.

    Science.gov (United States)

    Kerkhoff, Wim; Alberink, Ivo; Mattijssen, Erwin J A T

    2018-01-01

    In this study, the cartridge case ejection patterns of six different Glock model pistols (one specimen per model) were compared under three conditions: firing with a loaded magazine, an empty magazine, and without magazine. The distances, covered by the ejected cartridge cases given these three conditions, were compared for each of the six models. A significant difference was found between the groups of data for each of the tested specimens. This indicates that it is important that, to reconstruct a shooting scene incident based on the ejection patterns of a pistol, test shots are fired with the same pistol type and under the correct magazine condition. © 2017 American Academy of Forensic Sciences.

  2. Combustible Cartridge Cases: Current Status and Future Prospects

    Science.gov (United States)

    1992-08-01

    and presents new models of combustible cartridge case burning . Following a summary of experimental data, it concludes with proposals for further...UNCLASSIFIED UNCLASSIFIED UNCLASSIFIED SAR NSN 7540-01-280-5500 Standard Form 298 (Rev 2-89) Precribed by ANSI Std Z39-19 IWFENTIONALLY LEFT BLANK...7 3.3 In-Depth Burning Model ........................................ 7 3.3.1 M odel A ................................................ 9 3.3.2

  3. Investigation of effective forensic cleaning methods for bullet and cartridge case samples

    Science.gov (United States)

    Shuherk, Cassie Marie

    Bullet and cartridge case evidence may potentially link weapons and crimes through the comparison of toolmark patterns. This analysis relies on the clarity of the toolmarks and the ability of the examiner to identify patterns on the evidence. These patterns may be distorted by debris such as soil, blood, cyanoacrylate, and construction materials. Despite the potential importance of bullet and cartridge case evidence, few investigations of proper cleaning methods have been conducted. The present study was designed to examine the effects of various cleaning solutions and application methods on copper and brass bullets and cartridge cases. Additionally, this research investigated the efficacy of these cleaning protocols on the common evidence contaminants blood and cyanoacrylate. No cleaning method was found to be universally effective on both contaminant types and nondestructive to the metal surface. Ultrasonication was the most efficient application method employed when used in conjunction with an appropriate cleaning solution. Acetone proved to be safe and successful at removing heavy cyanoacrylate deposits from brass cartridge cases without damaging the metal. Although sulfuric acid removed most of the cyanoacrylate from the brass cartridge case, ultrasonication of the fumed cartridge cases in sulfuric acid caused the nickel-plated primer caps to turn black. Additionally, etching occurred when sulfuric acid was allowed to dry on the cartridge case surface. Citric acid, salt-flour-vinegar paste, TergazymeRTM, and water did not effectively remove the cyanoacrylate from the cartridge cases, but the solutions were safe to use on the brass and sometimes resulted in a shinier surface. Regardless of the cleaning method employed, the bloodstained bullets retained most or all of the underlying brown tarnish. Ultrasonication with sulfuric acid was successful at removing some blood-initiated tarnishing; however, the removal of residues was not complete, making it difficult

  4. 25MM Plastic Telescoped Cartridge Case Development Program

    Science.gov (United States)

    1975-01-01

    Mat’ I____ Projectile: 0wq. No. 30033;7,Rev, A, Platic "Band, 3000 Grain. Primer: Type .SmL. , Lot No.,, , Ne. . Flash Tubet.l3TSpe 1ell Project l...8217 _ ’_"__ Projectile: Dwg. No. 300347, Ray. A, Platic Biand, 3000 Graln. Primer: Type P-SIT.ML , Lot No. . No, Flash Tube:c<# 7’Tr-pecla1, Projectile Rot ntlo...Case: N ,o Rev. ___, Mati:.l, ILt Dwg. No,._____ Rev. M Nt l______Projectile: Dwg, No. 300347, ev • A, Platic ’ t -and, 3000 Grain, Primers Type , Lot

  5. Motion-Based pH Sensing Based on the Cartridge-Case-like Micromotor.

    Science.gov (United States)

    Su, Yajun; Ge, Ya; Liu, Limei; Zhang, Lina; Liu, Mei; Sun, Yunyu; Zhang, Hui; Dong, Bin

    2016-02-17

    In this paper, we report a novel cartridge-case-like micromotor. The micromotor, which is fabricated by the template synthesis method, consists of a gelatin shell with platinum nanoparticles decorating its inner surface. Intriguingly, the resulting cartridge-case-like structure exhibits a pH-dependent "open and close" feature, which originates from the pH responsiveness of the gelatin material. On the basis of the catalytic activity of the platinum nanoparticle inside the gelatin shell, the resulting cartridge-case-like structure is capable of moving autonomously in the aqueous solution containing the hydrogen peroxide fuel. More interestingly, we find out that the micromotor can be utilized as a motion-based pH sensor over the whole pH range. The moving velocity of the micromotor increases monotonically with the increase of pH of the analyte solution. Three different factors are considered to be responsible for the proportional relation between the motion speed and pH of the analyte solution: the peroxidase-like and oxidase-like catalytic behavior of the platinum nanoparticle at low and high pH, the volumetric decomposition of the hydrogen peroxide under the basic condition and the pH-dependent catalytic activity of the platinum nanoparticle caused by the swelling/deswelling behavior of the gelatin material. The current work highlights the impact of the material properties on the motion behavior of a micromotor, thus paving the way toward its application in the motion-based sensing field.

  6. A Modified Electrostatic Adsorption Apparatus for Latent Fingerprint Development on Unfired Cartridge Cases.

    Science.gov (United States)

    Xu, Jingyang; Zhang, Ziyuan; Zheng, Xiaochun; Bond, John W

    2017-05-01

    Visualization of latent fingerprints on metallic surfaces by the method of applying electrostatic charging and adsorption is considered as a promising chemical-free method, which has the merit of nondestruction, and is considered to be effective for some difficult situations such as aged fingerprint deposits or those exposed to environmental extremes. In fact, a portable electrostatic generator can be easily accessible in a local forensic technology laboratory, which is already widely used in the visualization of footwear impressions. In this study, a modified version of this electrostatic apparatus is proposed for latent fingerprint development and has shown great potential in visualizing fingerprints on metallic surfaces such as cartridge cases. Results indicate that this experimental arrangement can successfully develop aged latent fingerprints on metal surfaces, and we demonstrate its effectiveness compared with existing conventional fingerprint recovery methods. © 2016 American Academy of Forensic Sciences.

  7. Identifying persistent and characteristic features in firearm tool marks on cartridge cases

    Science.gov (United States)

    Ott, Daniel; Soons, Johannes; Thompson, Robert; Song, John

    2017-12-01

    Recent concerns about subjectivity in forensic firearm identification have motivated the development of algorithms to compare firearm tool marks that are imparted on ammunition and to generate quantitative measures of similarity. In this paper, we describe an algorithm that identifies impressed tool marks on a cartridge case that are both consistent between firings and contribute strongly to a surface similarity metric. The result is a representation of the tool mark topography that emphasizes both significant and persistent features across firings. This characteristic surface map is useful for understanding the variability and persistence of the tool marks created by a firearm and can provide improved discrimination between the comparison scores of samples fired from the same firearm and the scores of samples fired from different firearms. The algorithm also provides a convenient method for visualizing areas of similarity that may be useful in providing quantitative support for visual comparisons by trained examiners.

  8. Determining the effect of cartridge case coatings on GSR using post-fire priming cup residue.

    Science.gov (United States)

    Terry, Molly; Fookes, Barry; Bridge, Candice M

    2017-07-01

    Ammunition is typically composed of a lead-based priming mixture which contributes to the characteristics most commonly used for the identification of gunshot residue (GSR). Due to the health risks often associated with lead, the use of lead-free primers in ammunitions is becoming more popular. Thus, the presence of GSR is becoming more difficult to discern based on the traditional means, i.e. the presence of lead (Pb), barium (Ba), and antimony (Sb). While research has been conducted on the differences between lead-based and lead-free muzzle discharge residue, few have researched other components of ammunition which may lead to other means of characterizing GSR. This research, therefore, covers that gap by focusing on the priming cup present in ammunition and the residue which may originate from it, that can contribute to muzzle discharge residue. In this study, a lead-based and a lead-free ammunition from four different manufacturers were chosen. The cartridges were fired using a Glock 17, 9mm Parabellum, collected post-fire, and subsequently de-primed resulting in the removal of the anvil. The GSR present on the anvils and cups was analyzed using scanning electron microscopy coupled with energy dispersive x-ray spectrometry (SEM-EDX). The data was then processed using unit vector analysis for normalization and analyzed using principal component analysis (PCA) and linear discriminant analysis (LDA). This data was then used to determine the components of the cartridge case which contribute to GSR and develop a method of characterization between lead-free and lead-based ammunition. Such a method will improve the detection of GSR by strengthening the criteria of identification. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. A patterned abrasion caused by the impact of a cartridge case may simulate an atypical muzzle imprint mark.

    Science.gov (United States)

    Kramer, Lena; Nadjem, Hadi; Glardon, Matthieu; Kneubuehl, Beat P; Pollak, Stefan; Große Perdekamp, Markus; Pircher, Rebecca

    2016-05-01

    In contact shots, the muzzle imprint is an informative finding associated with the entrance wound. It typically mirrors the constructional components being in line with the muzzle or just behind. Under special conditions, other patterned skin marks located near a gunshot entrance wound may give the impression to be part of the muzzle imprint. A potential mechanism causing a patterned pressure abrasion in close proximity to the bullet entrance site is demonstrated on the basis of a suicidal shot to the temple. The skin lesion in question appeared as a ring-shaped excoriation with a diameter corresponding to that of the cartridge case. Two hypotheses concerning the causative mechanism were investigated by test shots: - After being ejected, the cartridge case ricocheted inside a confined space (car cabin in the particular case) and secondarily hit the skin near the gunshot entrance wound. - The ejection of the cartridge case failed so that the case became stuck in the ejection port and its mouth contacted the skin when the body collapsed after being hit.

  10. Influence Factors Regarding the Effectiveness of Automated Ballistic Comparison on 0.38 Special Caliber Bullets and Cartridge Cases.

    Science.gov (United States)

    Dos Santos, Lehi Sudy; Vieira Muterlle, Palloma

    2018-03-01

    Factors influencing effectiveness of automated comparisons, test-fired bullets, and cartridge cases from 0.38 Special revolvers were logged into the Evofinder ® Ballistic ID System. Tests were performed as follows: First test correlated test-fires of the same type, second test compared different types of ammunition components, third test replicated the second test in a larger database, and fourth test replicated the third test with students having no previous firearm identification experience. System effectiveness with projectiles in the first test was 0.89. With cartridge cases, effectiveness was 0.79 with combined results, but analysis of separate results by breech face and firing pin revealed low effectiveness by breech face (0.40). In the second, third, and fourth tests, effectiveness with projectiles were 0.61, 0.51, and 0.44. In addition, these tests had effectiveness with cartridge cases equivalent to 0.55, 0.43, and 0.44. Results are useful to establish routine protocols, system improvements, or comparative assessment of other electronic systems. © 2018 American Academy of Forensic Sciences.

  11. Determining Service Life of Respirator Cartridges Using a Simple and Practical Method: Case Study in a Car Manufacturing Industry

    Directory of Open Access Journals (Sweden)

    A.M Rashidi

    2012-01-01

    Full Text Available Background and aims: For ensuring about proper performance of air-purifying respirators in providing protection against workplace contaminants, it is necessary to change the respirator cartridges before the end of their service life. The aim of this study was determination of service life of organic vapor cartridges using a simple and practical method in a spray painting booth of a car manufacturing industry.   Methods: NIOSH MultiVapor software was used for estimating service life of respirator cartridges based on workplace conditions and cartridge specifications. Efficiency of determined service life was investigated using an apparatus for field testing of cartridges in the workplace.   Results: The results showed that existing schedule for changing the respirator cartridges is not effective and no longer provide adequate protection for sprayers against organic contaminants while working in a painting booth. It is necessary to change the cartridges before their estimated service life (every 4 hours.   Conclusion: NIOSH MultiVapor has acceptable efficiency for determining respirator cartridges service life and could be used as a simple and practical method in the workplace. Moreover, Service life estimated by this software was confirmed by cartridge field test apparatus.

  12. A comparison of surface topography characterization technologies for use in comparing spent bullet and cartridge case signatures

    Energy Technology Data Exchange (ETDEWEB)

    Batishko, C.R.; Hickman, B.J.; Cuta, F.M.

    1992-11-01

    The Pacific Northwest Laboratory was tasked by the US Department of Energy to provide technical assistance to the Federal Bureau of Investigation in evaluating and ranking technologies potentially useful in high-speed comparison of unique spent bullet and cartridge case surface signatures. Information sources included vendor input, current relevant literature, vendor phone contacts, other FBI resources, relevant PNL reports, and personal contact with numerous PNL technical staff. A comprehensive list of technologies was reduced to a list of 38 by grouping very similar methodologies, and further reduced to a short list of six by applying a set of five minimum functional requirements. A total of 14 primary criteria, many having secondary criteria, were subsequently used to evaluate each technology. The ranked short list results are reported and supported in this document, and their scores normalized to a hypothetical ideal system are as follows: (1) confocal microscopy 82.13; (2) laser dynamic focusing 72.04; (3)moire interferometry V70.94; (4)fringe field capacitance;(5)laser triangulation 66.18; (6)structured/sectioned light 65.55. Information available within the time/budget constraints which was used for the evaluation and ranking was not sufficiently detailed to evaluate specific implementations of the technologies. Each of the technologies in the short list was judged potentially capable of meeting the minimum requirements. Clever, novel engineering solutions resulting in a more cost-effective system, or a closer fit to the ``ideal system,`` could result in a reordering of the short list when actual technical proposals are evaluated. Therefore, it is recommended that a Request for Proposal not be limited to only the highest ranked technology, but include all six technologies in the short list.

  13. A comparison of surface topography characterization technologies for use in comparing spent bullet and cartridge case signatures

    Energy Technology Data Exchange (ETDEWEB)

    Batishko, C.R.; Hickman, B.J.; Cuta, F.M.

    1992-11-01

    The Pacific Northwest Laboratory was tasked by the US Department of Energy to provide technical assistance to the Federal Bureau of Investigation in evaluating and ranking technologies potentially useful in high-speed comparison of unique spent bullet and cartridge case surface signatures. Information sources included vendor input, current relevant literature, vendor phone contacts, other FBI resources, relevant PNL reports, and personal contact with numerous PNL technical staff. A comprehensive list of technologies was reduced to a list of 38 by grouping very similar methodologies, and further reduced to a short list of six by applying a set of five minimum functional requirements. A total of 14 primary criteria, many having secondary criteria, were subsequently used to evaluate each technology. The ranked short list results are reported and supported in this document, and their scores normalized to a hypothetical ideal system are as follows: (1) confocal microscopy 82.13; (2) laser dynamic focusing 72.04; (3)moire interferometry V70.94; (4)fringe field capacitance;(5)laser triangulation 66.18; (6)structured/sectioned light 65.55. Information available within the time/budget constraints which was used for the evaluation and ranking was not sufficiently detailed to evaluate specific implementations of the technologies. Each of the technologies in the short list was judged potentially capable of meeting the minimum requirements. Clever, novel engineering solutions resulting in a more cost-effective system, or a closer fit to the ideal system,'' could result in a reordering of the short list when actual technical proposals are evaluated. Therefore, it is recommended that a Request for Proposal not be limited to only the highest ranked technology, but include all six technologies in the short list.

  14. IBM 3480 tape cartridge

    CERN Multimedia

    1984-01-01

    The 3480 tape format is a magnetic tape data storage format developed by IBM. The cartridge contains a single reel. IBM’s 3480 cartridge tape system sought to replace the traditional reels of magnetic tape in the computer center. Because of their speed, reliability, durability and low media cost, these tapes and tape drives are still in high demand. A hallmark of the genre is transferability. Tapes recorded with one tape drive are generally readable on another drive, even if the tape drives were built by different manufacturers.

  15. Radiation damage of nonmetallic solids

    International Nuclear Information System (INIS)

    Goland, A.N.

    1975-01-01

    A review of data and information on radiation damage in nonmetallic solids is presented. Discussions are included on defects in nonmetals, radiation damage processes in nonmetals, electronic damage processes, physical damage processes, atomic displacement, photochemical damage processes, and ion implantation

  16. Penetrating chest trauma caused by a blank cartridge actuated rubber ball projectile: case presentation and ballistic investigation of an uncommon weapon type.

    Science.gov (United States)

    Frank, Matthias; Peters, Dieter; Klemm, Wolfram; Grossjohann, Rico; Ekkernkamp, Axel; Bockholdt, Britta; Seifert, Julia

    2017-09-01

    Recently, an increasing number of an uncommon weapon type based on a caliber 6-mm Flobert blank cartridge actuated revolver which discharges 10-mm-diameter rubber ball projectiles has been confiscated by police authorities following criminal offenses. A recent trauma case presenting with a penetrating chest injury occasioned an investigation into the basic ballistic parameters of this type of weapon. Kinetic energy E of the test projectiles was calculated between 5.8 and 12.5 J. Energy density ED of the test projectiles was close to or higher than the threshold energy density of human skin. It can be concluded that penetrating skin injuries due to free-flying rubber ball projectiles discharged at close range cannot be ruled out. However, in case of a contact shot, the main injury potential of this weapon type must be attributed to the high energy density of the muzzle gas jet which may, similar to well-known gas or alarm weapons, cause life-threatening or even lethal injuries.

  17. Positron annhilation in nonmetallic solids

    International Nuclear Information System (INIS)

    Cizek, A.; Sob, M.; Dekhtyar, I. Ya.

    1979-01-01

    In positron annihilation investigations of nonmetallic solids, the standard deviation of the gaussian component of the angular correlation curve is elucidated as material constant. It is related to the apparent radius of the chemical unit of the substance in question. (Auth.)

  18. Economic impact of using nonmetallic materials in low to intermediate temperature geothermal well construction

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    Four appendices are included. The first covers applications of low-temperature geothermal energy including industrial processes, agricultural and related processes, district heating and cooling, and miscellaneous. The second discusses hydrogeologic factors affecting the design and construction of low-temperature geothermal wells: water quality, withdrawal rate, water depth, water temperature, basic well designs, and hydrogeologic provinces. In the third appendix, properties of metallic and nonmetallic materials are described, including: specific gravity, mechanical strength properties, resistance to physical and biological attack, thermal properties of nonmetallics, fluid flow characteristics, corrosion resistance, scaling resistance, weathering resistance of nonmetallics, and hydrolysis resistance of nonmetallics. Finally, special considerations in the design and construction of low-temperature geothermal wells using nonmetallics materials are covered. These include; drilling methods, joining methods, methods of casing and screen installation, well cementing, and well development. (MHR)

  19. The Indicating FTA Elute Cartridge

    Science.gov (United States)

    de Bie, Roosmarie P.; Schmeink, Channa E.; Bakkers, Judith M.J.E.; Snijders, Peter J.F.; Quint, Wim G.V.; Massuger, Leon F.A.G.; Bekkers, Ruud L.M.; Melchers, Willem J.G.

    2011-01-01

    The clinically validated high-risk human papillomavirus (hrHPV) Hybrid Capture 2 (HC2) and GP5+/6+-PCR assays were analyzed on an Indicating FTA Elute cartridge (FTA cartridge). The FTA cartridge is a solid dry carrier that allows safe transport of cervical samples. FTA cartridge samples were compared with liquid-based samples for hrHPV and high-grade cervical intraepithelial neoplasia (CIN) detection. One cervical sample was collected in a liquid-based medium, and one was applied to the FTA cartridge. DNA was eluted directly from the FTA cartridge by a simple elution step. HC2 and GP5+/6+-PCR assays were performed on both the liquid-based and the FTA-eluted DNA of 88 women. Overall agreement between FTA and liquid-based samples for the presence of hrHPV was 90.9% with GP5+/6+-PCR and 77.3% with HC2. The sensitivity for high-grade CIN of hrHPV testing on the FTA cartridges was 84.6% with GP5+/6+-PCR and only 53.8% with HC2. By comparison, these sensitivities on liquid-based samples were 92.3% and 100% for GP5+/6+-PCR and HC2, respectively. Therefore, the FTA cartridge shows reasonably good overall agreement for hrHPV detection with liquid-based media when using GP5+/6+-PCR but not HC2 testing. Even with GP5+/6+-PCR, the FTA cartridge is not yet capable of detecting all high-grade CIN lesions. PMID:21704269

  20. Thermal analysis with expendable cartridge

    International Nuclear Information System (INIS)

    Susaki, K.; Landgraf, F.J.G.

    1981-01-01

    The pratical method of thermal analysis with expendable cartridge and some aspects of its use are presented. The results of the method applied to the system Nb-Mn are presented together with data from microprobe. (Author) [pt

  1. Bipolarons in nonmetallic crystals

    International Nuclear Information System (INIS)

    Vinetskii, V.L.; Pashitskii, E.A.; Yanchuk, V.A.

    1987-01-01

    The binding energy of a bipolaron in an ionic crystal increases substantially in the case of strong anisotropy of the effective masses of the free carriers of the easy plane type or easy axis type. In the second case the polaron is cigar-like in shape and the coaxial configuration of bipolarons is energetically favorable. In this case a significant gain in the binding energy and in the width of the region of existence of the bipolaron, with respect to the dielectric constant and the magnitude of the electron-phonon interaction constant, compared with an isotropic crystal, is obtained only for quasi-two-dimensional, or layered, and quasi-one-dimensional, or chainlike, crystals. This work shows that a significant gain in the binding energy can be obtained by taking into account the anisotropy of the dielectric constant of the crystal and localization of the electron wave functions in directions perpendicular to the layers and chains of atoms

  2. The Imation 9840 Tape Cartridge

    CERN Multimedia

    It’s a 20 GB uncompressed center-load cartridge used in StorageTek T9840 tape drives. The tape is a Metal Particle (MP) tape suitable for use on all Oracle/Sun/StorageTek 9840 A, B, C and D drives. The 9840 tape has an archival life of 15-30 years.

  3. Quick-change filter cartridge

    Science.gov (United States)

    Rodgers, John C.; McFarland, Andrew R.; Ortiz, Carlos A.

    1995-01-01

    A quick-change filter cartridge. In sampling systems for measurement of airborne materials, a filter element is introduced into the sampled airstream such that the aerosol constituents are removed and deposited on the filter. Fragile sampling media often require support in order to prevent rupture during sampling, and careful mounting and sealing to prevent misalignment, tearing, or creasing which would allow the sampled air to bypass the filter. Additionally, handling of filter elements may introduce cross-contamination or exposure of operators to toxic materials. Moreover, it is desirable to enable the preloading of filter media into quick-change cartridges in clean laboratory environments, thereby simplifying and expediting the filter-changing process in the field. The quick-change filter cartridge of the present invention permits the application of a variety of filter media in many types of instruments and may also be used in automated systems. The cartridge includes a base through which a vacuum can be applied to draw air through the filter medium which is located on a porous filter support and held there by means of a cap which forms an airtight seal with the base. The base is also adapted for receiving absorbing media so that both particulates and gas-phase samples may be trapped for investigation, the latter downstream of the aerosol filter.

  4. StorageTek T10000 Data Cartridge

    CERN Multimedia

    This data cartridge works on several StorageTek systems. The goal is to provide cartridge compatibility across several system. It has been designed for space saving and ultra-high capacity tape. It permit to fulfill high-volume backup, archiving, and disaster recovery.

  5. 49 CFR 193.2187 - Nonmetallic membrane liner.

    Science.gov (United States)

    2010-10-01

    ... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES: FEDERAL SAFETY STANDARDS Design Lng Storage Tanks § 193.2187 Nonmetallic membrane liner. A flammable nonmetallic membrane liner may not be used as an inner container in a storage tank...

  6. StorageTek T10000 Tape Cartridge

    CERN Multimedia

    1985-01-01

    Oracle StorageTek T10000T2 cartridge has total capacity of 5 TB. It is actually manufactured by Fuji Film, uses Barium Ferrite (BaFe) particles technology data store, but is also equipped with RFID chip. There is over 1 km of tape inside of the cartridge with 3584 data tracks and it supports over 25000 load/unload cycles. The archival life is estimated to be around 30 years and uncorrected bit error rate is 10-19. CERN however usually migrates data to newer technologies roughly every 5 years in order to keep the footprint under control.

  7. Nonmetallic inclusions in JBK-75 stainless steel

    International Nuclear Information System (INIS)

    Brewer, A.W.; Krenzer, R.W.; Doyle, J.H.; Riefenberg, D.H.

    1977-01-01

    Stainless steel alloys that are chemically complex, such as A-286 or JBK-75, are designed to improve such high-temperature properties as strength. This is accomplished by precipitating secondary phases during aging. Such multicomponent systems, however, can also produce undesirable phases that are detrimental to forgeability and final mechanical properties. Cast segregation and numerous nonmetallic inclusions can have a degrading influence on the toughness and ductility of the alloy. Several different heats of A-286 and JBK-75 were studied, and titanium carbide and/or molybdenum carbide [(Ti, Mo)C] plus titanium carbide and/or titanium carbonitride Ti(C,N)-type phases were qualitatively identified as the major nonmetallic constituent in these alloys. The common procedure for rating the microcleanliness of steels does not classify such carbide or carbonitride phases and thus does not provide an appropriate means of controlling in-process inspection. The results of this study are discussed in terms of alternative methods for evaluating the microcleanliness of superalloys

  8. The reactor Phenix - cartridge rupture detection

    International Nuclear Information System (INIS)

    Graftieaux, J.

    1967-01-01

    This report defines the role of cartridge rupture detection in the reactor Phenix. It gives the possible methods, their probable performances, their advantages and disadvantages. The final form of the installation will be determined mainly by the degree of safety required, by the technical possibilities of the reactor design and by the operational flexibility wanted. (author) [fr

  9. CONSTRUCTION AND OPTIMISATION OF A CARTRIDGE FILTER ...

    African Journals Online (AJOL)

    a

    1Department of Chemistry, Egerton University, P.O. Box 356, Njoro, Kenya .... the resident time in the filter, thus there is not enough time for F- to interact with the ... associated with creation of too much backpressure in the cartridge as well as ...

  10. Non-metallic gage for gap

    International Nuclear Information System (INIS)

    Hiroki, Hideo.

    1996-01-01

    The present invention concerns a non-metallic gage for detecting a gap which can not be seen from the out side such as a gap between a water pipe and fuel rods without damaging an objective material as to whether the gap is formed within a standard value or not. The gage is made of a synthetic resin, for example, polyacetal having such a hardness as not damaging the objective material and endurable to repeating flexure upon use. The gage comprises a short gage portion having a predetermined standard thickness and an flexible extended connection portion reduced in the thickness. Provision of the extended connection portion enables wide range flexure thereof such as ±60deg relative to insertion direction during insertion operation upon testing to solve a drawback in the prior art such as worry of breakage of the gage, thereby enabling to conduct inspection rapidly at high reliability. (N.H.)

  11. The Method of Manufacturing Nonmetallic Test-Blocks on Different Sensitivity Classes

    Science.gov (United States)

    Kalinichenko, N. P.; Kalinichenko, A. N.; Lobanova, I. S.; Zaitseva, A. A.; Loboda, E. L.

    2016-01-01

    Nowadays in our modern world there is a vital question of quality control of details made from nonmetallic materials due to their wide spreading. Nondestructive penetrant testing is effective, and in some cases it is the only possible method of accidents prevention at high- risk sites. A brief review of check sample necessary for quality evaluation of penetrant materials is considered. There was offered a way of making agents for quality of penetrant materials testing according to different liquid penetrant testing sensibility classes.

  12. Non-metallic structural wrap systems for pipe

    International Nuclear Information System (INIS)

    Walker, R.H.; Wesley Rowley, C.

    2001-01-01

    The use of thermoplastics and reinforcing fiber has been a long-term application of non-metallic material for structural applications. With the advent of specialized epoxies and carbon reinforcing fiber, structural strength approaching and surpassing steel has been used in a wide variety of applications, including nuclear power plants. One of those applications is a NSWS for pipe and other structural members. The NSWS is system of integrating epoxies with reinforcing fiber in a wrapped geometrical configuration. This paper specifically addresses the repair of degraded pipe in heat removal systems used in nuclear power plants, which is typically caused by corrosion, erosion, or abrasion. Loss of structural material leads to leaks, which can be arrested by a NSWS for the pipe. The technical aspects of using thermoplastics to structurally improve degraded pipe in nuclear power plants has been addressed in the ASME B and PV Code Case N-589. Using the fundamentals described in that Code Case, this paper shows how this technology can be extended to pipe repair from the outside. This NSWS has already been used extensively in non-nuclear applications and in one nuclear application. The cost to apply this NSWS is typically substantially less than replacing the pipe and may be technically superior to replacing the pipe. (author)

  13. Secondary defects in non-metallic solids

    International Nuclear Information System (INIS)

    Ashbee, K.H.G.; Hobbs, L.W.

    1977-01-01

    This paper points out features of secondary defect formation which are peculiar to non-metallic solids (excluding elemental semiconductors). Most of the materials of interest are compounds of two or more (usually more or less ionic) atomic species, and immediate consequence of which is a need to maintain both stoichiometry (or accommodate non-stoichiometry) and order. Primary defects in these solids, whether produced thermally, chemically or by irradiation, seldom are present or aggregate in exactly stoichiometric proportions, and the resulting extending defect structures can be quite distinct from those found in metallic solids. Where stoichiometry is maintained, it is often convenient to describe extended defects in terms of alterations in the arrangement of 'molecular' units. The adoption of this procedure enables several novel features of extended defect structures in non-metals to be explained. There are several ways in which a range of non-stoichiometry can be accommodated, which include structural elimination of point defects, nucleation of new coherent phases of altered stoichiometry, and decomposition. (author)

  14. Test plan for the irradiation of nonmetallic materials.

    Energy Technology Data Exchange (ETDEWEB)

    Brush, Laurence H.; Farnum, Cathy Ottinger; Gelbard, Fred; Dahl, M.; Joslyn, C. C.; Venetz, T. J.

    2013-03-01

    A comprehensive test program to evaluate nonmetallic materials use in the Hanford Tank Farms is described in detail. This test program determines the effects of simultaneous multiple stressors at reasonable conditions on in-service configuration components by engineering performance testing.

  15. Test plan for the irradiation of nonmetallic materials.

    Energy Technology Data Exchange (ETDEWEB)

    Brush, Laurence H.; Farnum, Cathy Ottinger; Dahl, M.; Joslyn, C. C.; Venetz, T. J.

    2013-05-01

    A comprehensive test program to evaluate nonmetallic materials use in the Hanford tank farms is described in detail. This test program determines the effects of simultaneous multiple stressors at reasonable conditions on in-service configuration components by engineering performance testing.

  16. The assessment of non-metallic inclusions in steels and nickel alloys for ultra high vacuum applications

    International Nuclear Information System (INIS)

    Meriguet, P.J.-L.

    1992-01-01

    The presence of non-metallic inclusions in steels and nickel alloys may create leak-paths under Ultra High Vacuum conditions. This paper shows the application of the ASTM E45 standard to the assessment of these inclusions and gives some design recommendations. Three case-histories encountered at the Joint European Torus Joint Undertaking and a possible explanation of the phenomenon are also presented. (Author)

  17. Indústria de cartucho de toner sob a ótica da remanufatura: estudo de caso de um processo de melhoria Remanufacturing of toner cartridge: a case study of a improvement process

    Directory of Open Access Journals (Sweden)

    Cícero Ferreira Fernandes Costa Filho

    2006-04-01

    Full Text Available Este trabalho apresenta um estudo de caso de um processo de melhoria aplicado a uma indústria de remanufatura de cartuchos de toner. Inicialmente, é feita uma abordagem do processo de remanufatura procurando salientar as principais características que o diferenciam de um processo de manufatura convencional e a importância do mesmo diante das preocupações ambientais atuais. Através de três indicadores de desempenho propostos no trabalho fez-se um diagnóstico do processo de remanufatura quanto ao aproveitamento de peças recolhidas do campo, atendimento de pedidos dos clientes e quantidade de defeitos. No diagnóstico inicial realizado, os valores obtidos para esses critérios situaram-se abaixo das metas estabelecidas na empresa. Através da metodologia PDCA, identificaram-se oportunidades de melhorias em pontos críticos do processo de fabricação. A implantação dessas melhorias resultou em ganhos nos indicadores de desempenho da ordem de 12%. Algumas ferramentas clássicas foram utilizadas para auxiliar na implementação da metodologia PDCA destacando-se brainstorming, diagrama de Ishikawa e Controle Estatístico de Processo.This paper presents an improvement process applied in one remanufacturing toner cartridge industry. It, initially, presents a mapping of the stages of this process by attempting to highlight the main characteristics, which distinguish it from a conventional manufacturing process and emphasizes its importance as an of eco-efficient process aiming at achieving sustainable development. Through three performance indicators proposed by the work, a diagnosis of the existing process was carried out as to the reuse of parts gasthered in the field, fulfilment of customers'orders and quantity of production faults. At the initial diagnosis carried out, the values obtained for theses criteria were located below the established targets proposed by the company. Through the PDCA tool, improvement opportunities in critical

  18. Cutting of nonmetallic materials using Nd:YAG laser beam

    Institute of Scientific and Technical Information of China (English)

    Bashir Ahmed Tahir; Rashid Ahmed; M. G. B. Ashiq; Afaq Ahmed; M. A. Saeed

    2012-01-01

    This study deals with Nd:YAG laser cutting nonmetallic materials,which is one of the most important and popular industrial applications of laser.The main theme is to evaluate the effects of Nd:YAG laser beam power besides work piece scanning speed.For approximate cutting depth,a theoretical study is conducted in terms of material property and cutting speed.Results show a nonlinear relation between the cutting depth and input energy.There is no significant effect of speed on cutting depth with the speed being larger than 30 mm/s.An extra energy is utilized in the deep cutting.It is inferred that as the laser power increases,cutting depth increases.The experimental outcomes are in good agreement with theoretical results.This analysis will provide a guideline for laser-based industry to select a suitable laser for cutting,scribing,trimming,engraving,and marking nonmetallic materials.

  19. Cutting of nonmetallic materials using Nd:YAG laser beam

    International Nuclear Information System (INIS)

    Tahir, Bashir Ahmed; Ashiq, M.G. B.; Saeed, M.A.; Ahmed, Rashid; Ahmed, Afaq

    2012-01-01

    This study deals with Nd:YAG laser cutting nonmetallic materials, which is one of the most important and popular industrial applications of laser. The main theme is to evaluate the effects of Nd:YAG laser beam power besides work piece scanning speed. For approximate cutting depth, a theoretical study is conducted in terms of material property and cutting speed. Results show a nonlinear relation between the cutting depth and input energy. There is no significant effect of speed on cutting depth with the speed being larger than 30 mm/s. An extra energy is utilized in the deep cutting. It is inferred that as the laser power increases, cutting depth increases. The experimental outcomes are in good agreement with theoretical results. This analysis will provide a guideline for laser-based industry to select a suitable laser for cutting, scribing, trimming, engraving, and marking nonmetallic materials. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  20. Nonmetallic inclusions in carbon steel smelted in plasma furnace

    Energy Technology Data Exchange (ETDEWEB)

    Shengelaya, I B; Kostyakov, V N; Nodiy, T K; Imerlishvili, V G; Gavisiani, A G [AN Gruzinskoj SSR, Tbilisi. Inst. Metallurgii

    1979-01-01

    A complex investigation on nonmetallic inclusions in carbon cast iron, smelted in plasma furnace in argon atmosphere and cast partly in the air and partly in argon atmosphere, has been carried out. As compared to open-hearth furnace carbon steel, the test metal was found to contain more oxide inclusions and nitrides; besides, in chromium-containing metal, chromium nitrides form the larger part of nitrides.

  1. Dissolution of nonmetallic inclusions at high-temperature heating

    International Nuclear Information System (INIS)

    Gubenko, S.I.

    1983-01-01

    The effect of high-temperature a nnealing on size, distribution and general content of non-metallic inclusions in steels is investigated. It is shown that high-temperature annealing of steel permits to reduce total amount of inclusions, their average size, as well as to control their composition and distribution in steel matrix. Partial or complete dissolution of inclusions takes place in respect to the type of non-metallic inclusions, temperature of annealing and holding duration. Cooling rate affects the investigated parameters. Under quenching the total amount of inclusions in steel is lower and average size of inclusions is larger than those under slow cooling. It is explained by precipitation of disperses ''satellites around the initial inclusions under low cooling. Composition of the satellites slightly differs from that of a ''mother's'' one. Change in composition of inclusions and creation of conditions for transition of unstable inclusions to a more stable state promotes change in properties of non-metallic inclusions that affects steel properties

  2. Criticality safety evaluation report for K Basin filter cartridges

    International Nuclear Information System (INIS)

    Schwinkendorf, K.N.

    1995-01-01

    A criticality safety evaluation of the K Basin filter cartridge assemblies has been completed to support operations without a criticality alarm system. The results show that for normal operation, the filter cartridge assembly is far below the safety limit of k eff = 0.95, which is applied to plutonium systems at the Hanford Site. During normal operating conditions, uranium, plutonium, and fission and corrosion products in solution are continually accumulating in the available void spaces inside the filter cartridge medium. Currently, filter cartridge assemblies are scheduled to be replaced at six month intervals in KE Basin, and at one year intervals in KW Basin. According to available plutonium concentration data for KE Basin and data for the U/Pu ratio, it will take many times the six-month replacement time for sufficient fissionable material accumulation to take place to exceed the safety limit of k eff = 0.95, especially given the conservative assumption that the presence of fission and corrosion products is ignored. Accumulation of sludge with a composition typical of that measured in the sand filter backwash pit will not lead to a k eff = 0.95 value. For off-normal scenarios, it would require at least two unlikely, independent, and concurrent events to take place before the k eff = 0.95 limit was exceeded. Contingencies considered include failure to replace the filter cartridge assemblies at the scheduled time resulting in additional buildup of fissionable material, the loss of geometry control from the filter cartridge assembly breaking apart and releasing the individual filter cartridges into an optimal configuration, and concentrations of plutonium at U/Pu ratios less than measured data for KE Basin, typically close to 400 according to extensive measurements in the sand filter backwash pit and plutonium production information

  3. On the determination of various metallic and nonmetallic impurities in sodium metal

    International Nuclear Information System (INIS)

    Schneider, H.; Gruenhaeuser, M.; Nagel, G.; Nold, E.; Schaefer, A.; Schumann, H.

    1976-04-01

    Methods for the determination of various metallic and nonmetallic impurities in sodium metal were developed or tested. Detection limits, reproducibilities and results of analyses are reported. (orig.) [de

  4. Adsorbent cartridge for the exhaust of diazo process machines

    International Nuclear Information System (INIS)

    Michlin, N.; Thies, E.J.

    1982-01-01

    A disposable cartridge filled with a chemical composition that acts as an adsorbent for ammonia vapor is adapted to be used in connection with a diazo process printing machine having a vacuum exhausted chamber. Exhaust from the chamber is passed through the cartridge to remove the noxious ammonia vapors and then is vented into the atmosphere. The cartridge is housed in an elongated rectangular cardboard box having three end flaps formed at each of its opposed open ends. Two opposed flaps of each set are formed with central holes and a plastic screen section adhered between these flaps to retain and allow access to the center section of the box which contains the adsorbent chemical. The center end flaps have knock-outs or tear strips that allow holes to be formed in their centers. These center end flaps cover the screens during shipment and when the cartridge is ready for use the center sections of these end flaps are knocked-out to allow the machine exhaust to be vented into and out of the cartridge

  5. NERVA turbopump bearing retainer fabrication on nonmetallic retainer

    Science.gov (United States)

    Accinelli, J. B.

    1972-01-01

    The need for a low-wear, lightweight, high strength bearing retainer material with a radiation degradation threshold of 10 to the 9th power rads (C) prompted development of nonmetallic reinforced polymers of the following types: (1) polybenzimidazole, (2) polyimide, and (3) polyquinoxaline. Retainers were machined from tubular laminates (billets), including reinforcement by either glass or graphite fabric or filament. Fabrication of billets involves hot preimpregnation of the reinforcement fabric or filament with polymer followed by wrapping this prepreg over a heated mandrel to form a tube with the required thickness and length.

  6. The Measurement of Hardness and Elastic Modulus of non-Metallic Inclusions in Steely Welding Joints

    Directory of Open Access Journals (Sweden)

    Ignatova Anna

    2015-08-01

    Full Text Available Trunk pipelines work under a cyclic dynamical mechanical load because when oil or gas is pumped, the pressure constantly changes - pulsates. Therefore, the fatigue phenomenon is a common reason of accidents. The fatigue phenomenon more often happens in the zone of non-metallic inclusions concentration. To know how the characteristics of nonmetallic inclusions influence the probability of an accident the most modern research methods should be used. It is determined with the help of the modern research methods that the accident rate of welded joints of pipelines is mostly influenced by their morphological type, composition and size of nonmetallic inclusions, this effect is more important than the common level of pollution by non-metallic inclusions. The article presents the results of the investigations of welded joints, obtained after the use of different common welding materials. We used the methods, described in the state standards: scanning electronic microscopy, spectral microprobe analysis and nano-indentation. We found out that non-metallic inclusions act like stress concentrators because they shrink, forming a blank space between metal and nonmetallic inclusions; it strengthens the differential properties on this boundary. Nonmetallic inclusion is not fixed, it can move. The data that we have received mean that during welded joints’ contamination (with non-metallic inclusions monitoring process, more attention should be paid to the content of definite inclusions, but not to total contamination.

  7. Effects of small defects and nonmetallic inclusions on the fatigue strength of metals

    International Nuclear Information System (INIS)

    Murakami, Y.

    1991-01-01

    The equation for predicting the effects of artificial small defects on the fatigue strength of metals is introduced, and it is applied to the quantitative evaluation of the effects of nonmetallic inclusions on the fatigue strength of high-strength steels. The importance of the concept that nonmetallic inclusions are virtually equivalent to defects, from the viewpoint of fatigue strength and, more practically, are equivalent to small cracks is emphasized. It is shown that nonmetallic inclusions cause relatively low-fatigue strength and large scatter of the fatigue strength of steels with high static strength or high hardness. The statistics of extreme values is used to estimate the expected maximum size of nonmetallic inclusions contained in a definite number of specimens. The lower limit of scatter in the fatigue strength of a high-strength steel is obtained by using the prediction equation for small defects together with the expected maximum size of nonmetallic inclusions

  8. 42 CFR 84.194 - Filters used with chemical cartridges; location; replacement.

    Science.gov (United States)

    2010-10-01

    ...; replacement. 84.194 Section 84.194 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN...; replacement. (a) Particulate matter filters used in conjunction with a chemical cartridge shall be located on... replacement on the cartridge. ...

  9. Two-gun suicide by simultaneous shots to the head: interdisciplinary reconstruction on the basis of scene investigation, autopsy findings, GSR analysis and examination of firearms, bullets and cartridge cases.

    Science.gov (United States)

    Grosse Perdekamp, Markus; Nadjem, Hadi; Merkel, Joachim; Braunwarth, Roland; Pollak, Stefan; Thierauf, Annette

    2011-07-01

    Suicidal shots fired simultaneously to the head from two handguns are rare. The authors report about a recent case in which a Smith & Wesson cal. 9 mm pistol and a Smith & Wesson cal. .357 Magnum revolver were used. Sitting on a sofa, a 33-year-old man (member of a shooting club) fired two simultaneous shots to the head; the pistol held in the left hand was discharged into the left temple, and the revolver held in the right hand was fired into the mouth. Both weapons remained in the respective hands. An upside-down muzzle imprint in the left temporal region and recoil injuries of a mandibular incisor, and the lower lip indicated that both the pistol and the revolver had been held in an inverted manner at the time of discharge. Blood stains (backspatter) and gunshot residues were present on both firing hands, whereas forward spatter originating from the exit wounds was deposited on the wall behind the suicide's head.

  10. Radiation damage in nonmetallic solids under dense electronic excitation

    International Nuclear Information System (INIS)

    Itoh, Noriaki; Tanimura, Katsumi; Nakai, Yasuo

    1992-01-01

    Basic processes of radiation damage of insulators by dense electronic excitation are reviewed. First it is pointed out that electronic excitation of nonmetallic solids produces the self-trapped excitons and defect-related metastable states having relatively long lifetimes, and that the excitation of these metastable states, produces stable defects. The effects of irradiation with heavy ions, including track registration, are surveyed on the basis of the microscopic studies. It is pointed out also that the excitation of the metastable states plays a role in laser-induced damage at relatively low fluences, while the laser damage has been reported to be governed by heating of free electrons produced by multiphoton excitation. Difference in the contributions of the excitation of metastable defects to laser-induced damage of surfaces, or laser ablation, and laser-induced bulk damage is stressed. (orig.)

  11. REM effect on nonmetallic inclusion composition and heat resistance in an austenitic steel

    International Nuclear Information System (INIS)

    Farafonov, V.K.; Shtejnberg, M.M.; Kikhtin, M.V.; Cheremnykh, V.P.; Vojnov, V.V.

    1979-01-01

    Studies were made to elucidate the effect of rare earths (lanthanum, neodymium, praseodymium, cerium) on the composition of non-metallic inclusions and heat resistance of an austenitic chromium-nickel steel. Common sulfide and oxide inclusions are shown to be substituted by rare earth sulfide and oxide inclusions at RE metal content in the steel up to 0.1%. Further increase of RE metal content results in increasing non-metallic inclusions containing RE metals, phosphorus and non-ferrous impurities. Creep rate changes insignificantly at RE metal content up to 0.1%, and then it sharply grows with the quantity of non-metallic inclusions in the steel

  12. Analyse and research of nonmetallic inclusions for steel 100Cr6

    Directory of Open Access Journals (Sweden)

    I. Vitez

    2009-01-01

    Full Text Available Steel 100Cr6 belongs to a group of hardened steels, which are applicable for production of rolling element parts. Because of specific working conditions, a proper chemical composition is required with a minimum content of nonmetallic inclusion. In this paper, the research results of presence the nonmetallic inclusions and their chemical composition are presented for the steel produced in vacuum and open induction electric furnace and their influence on the prescribed properties for this steel. The optical and scanning electronic microscope are used to identify presence and the chemical compositions of nonmetallic inclusions.

  13. Sensitivity analysis overlaps of friction elements in cartridge seals

    Directory of Open Access Journals (Sweden)

    Žmindák Milan

    2018-01-01

    Full Text Available Cartridge seals are self-contained units consisting of a shaft sleeve, seals, and gland plate. The applications of mechanical seals are numerous. The most common example of application is in bearing production for automobile industry. This paper deals with the sensitivity analysis of overlaps friction elements in cartridge seal and their influence on the friction torque sealing and compressive force. Furthermore, it describes materials for the manufacture of sealings, approaches usually used to solution of hyperelastic materials by FEM and short introduction into the topic wheel bearings. The practical part contains one of the approach for measurement friction torque, which results were used to specifying the methodology and precision of FEM calculation realized by software ANSYS WORKBENCH. This part also contains the sensitivity analysis of overlaps friction elements.

  14. Permanent disposal of radioactive particulate waste in cartridge containing ferromagnetic material

    International Nuclear Information System (INIS)

    Troy, M.

    1986-01-01

    This patent describes a cartridge for permanent disposal of solid radioactive particulate waste, comprising; a liquid impervious casing having an upper end cover, a lower end cover and a side wall extending between the covers, the casing enclosing a waste storage region; ferromagnetic fibrous material defining a waste retaining matrix and filling a major portion of the waste storage region; means defining an inlet conduit extending through the upper end cover and axially of the casing through the waste storage region, and opening into the waste storage region in the vicinity of the lower and end cover; and means defining first and second outlet conduits extending through the upper end cover and opening into the waste storage region in the vicinity of the upper end cover

  15. Ab-Initio Description and Prediction of Properties of Carbon-Based and Other Non-Metallic Materials

    Science.gov (United States)

    Bagayoko, D.; Zhao, G. L.; Hasan, S.

    2001-01-01

    We have resolved the long-standing problem consisting of 30%-50% theoretical underestimates of the band gaps of non-metallic materials. We describe the Bagayoko, Zhao, and Williams (BZW) method that rigorously circumvents the basis-set and variational effect presumed to be a cause of these underestimates. We present ab-initio, computational results that are in agreement with experiment for diamond (C), silicon (Si), silicon carbides (3C-SiC and 4H-SiC), and other semiconductors (GaN, BaTiO3, AlN, ZnSe, ZnO). We illustrate the predictive capability of the BZW method in the case of the newly discovered cubic phase of silicon nitride (c-Si3N4) and of selected carbon nanotabes [(10,0), and (8,4)]. Our conclusion underscores the inescapable need for the BZW method in ab-initio calculations that employ a basis set in a variational approach. Current nanoscale trends amplify this need. We estimate that the potential impact of applications of the BZW method in advancing our understanding of nonmetallic materials, in informing experiment, and particularly in guiding device design and fabrication is simply priceless.

  16. Effectiveness of Shot Peening In Suppressing Fatigue Cracking At Non-Metallic Inclusions In Udimet(Registered Trademark)720

    Science.gov (United States)

    Barrie, Robert L.; Gabb, Timothy P.; Telesman, Jack; Kantzos, Peter T.; Prescenzi, Anthony; Biles, T.; Bonacuse, P. J.

    2006-01-01

    The fatigue lives of modern powder metallurgy disk alloys can be reduced over an order of magnitude by cracking at inherent non-metallic inclusions. The objective of this work was to study the effectiveness of shot peening in suppressing LCF crack initiation and growth at surface nonmetallic inclusions. Inclusions were carefully introduced at elevated levels during powder metallurgy processing of the nickel-base disk superalloy Udimet 720. Multiple strain-controlled fatigue tests were then performed on machined specimens with and without shot peened test sections at 427 C and 650 C. The low cycle fatigue lives and failure initiation sites varied as functions of inclusion content, shot peening, and fatigue conditions. A large majority of the failures in as-machined specimens with the introduced inclusions occurred at cracks initiating from inclusions intersecting the specimen surface. These inclusions reduced fatigue life by up to 100X, when compared to lives of material without inclusions residing at specimen surface. Large inclusions produced the greatest reductions in life for tests at low strain ranges and high strain ratios. Shot peening improved life in many cases by reducing the most severe effects of inclusions.

  17. Enhanced angular overlap model for nonmetallic f -electron systems

    Science.gov (United States)

    Gajek, Z.

    2005-07-01

    An efficient method of interpretation of the crystal field effect in nonmetallic f -electron systems, the enhanced angular overlap model (EAOM), is presented. The method is established on the ground of perturbation expansion of the effective Hamiltonian for localized electrons and first-principles calculations related to available experimental data. The series of actinide compounds AO2 , oxychalcogenides AOX , and dichalcogenides UX2 where X=S ,Se,Te and A=U ,Np serve as probes of the effectiveness of the proposed method. An idea is to enhance the usual angular overlap model with ab initio calculations of those contributions to the crystal field potential, which cannot be represented by the usual angular overlap model (AOM). The enhancement leads to an improved fitting and makes the approach intrinsically coherent. In addition, the ab initio calculations of the main, AOM-consistent part of the crystal field potential allows one to fix the material-specific relations for the EAOM parameters in the effective Hamiltonian. Consequently, the electronic structure interpretation based on EAOM can be extended to systems of the lowest point symmetries or/and deficient experimental data. Several examples illustrating the promising capabilities of EAOM are given.

  18. Near-field millimeter - wave imaging of nonmetallic materials

    International Nuclear Information System (INIS)

    Gopalsami, N.; Bakhtiari, S.; Raptis, A.C.

    1996-01-01

    A near-field millimeter-wave (mm-wave) imaging system has been designed and built in the 94-GHz range for on-line inspection of nonmetallic (dielectric) materials. The imaging system consists of a transceiver block coupled to an antenna that scans the material to be imaged; a reflector plate is placed behind the material. A quadrature IF mixer in the transceiver block enables measurement of in-phase and quadrature-phase components of reflected signals with respect to the transmitted signal. All transceiver components, with the exception of the Gunn-diode oscillator and antenna, were fabricated in uniform blocks and integrated and packaged into a compact unit (12.7 x 10.2 x 2.5 cm). The objective of this work is to test the applicability of a near-field compact mm-wave sensor for on-line inspection of sheetlike materials such as paper, fabrics, and plastics. This paper presents initial near-field mm-wave images of paper and fabric samples containing known artifacts

  19. Characteristics of a cartridge NEG (St101 Zr-Al)

    International Nuclear Information System (INIS)

    Hisamatsu, Hiromi; Shimamoto, Masayuki; Kanazawa, Ken-ichi; Ishimaru, Hajime

    1990-01-01

    The report addresses the application of a non-evaporable getter (NEG) pump to an accelerator (storage ring). Tests are performed to determine major characteristics of the non-evaporable getter pump in an effort to provide a method for its efficient use. Test results show that with an St101 cartridge NEG pump, it is possible to produce an ultrahigh vacuum in a system with a surface area of about 10 4 cm 2 through baking at 410K for two hours. Once activated at 1000K, a NEG pump recovers a pumping performance in a subsequent test run at 723K, though the pumping speed decreases by several tens of percent. The St-101 cartridge type NEG pump is at least 2 Pam 3 in pumping capacity for carbon monoxide. The pumping speed decreases with an increasing amount of occluded carbon monoxide. Upon activation, most of the occluded carbon monoxide diffuses into the pump while only little of it is released into the gas phase. Its diffusion through the surface of the NEG pump can occur even at room temperature, indicating that if a leak takes place, the pump would absorb the gas continuously. Thus, if a leak occurs during activation, the pump would occlude a large amount of gas and therefore, activation should be carried out with careful checking for a leak. (N.K.)

  20. Bubble Jet agent release cartridge for chemical single cell stimulation.

    Science.gov (United States)

    Wangler, N; Welsche, M; Blazek, M; Blessing, M; Vervliet-Scheebaum, M; Reski, R; Müller, C; Reinecke, H; Steigert, J; Roth, G; Zengerle, R; Paust, N

    2013-02-01

    We present a new method for the distinct specific chemical stimulation of single cells and small cell clusters within their natural environment. By single-drop release of chemical agents with droplets in size of typical cell diameters (d agent release cartridge with integrated fluidic structures and integrated agent reservoirs are shown, tested, and compared in this publication. The single channel setup features a fluidic structure fabricated by anisotropic etching of silicon. To allow for simultaneous release of different agents even though maintaining the same device size, the second type comprises a double channel fluidic structure, fabricated by photolithographic patterning of TMMF. Dispensed droplet volumes are V = 15 pl and V = 10 pl for the silicon and the TMMF based setups, respectively. Utilizing the agent release cartridges, the application in biological assays was demonstrated by hormone-stimulated premature bud formation in Physcomitrella patens and the individual staining of one single L 929 cell within a confluent grown cell culture.

  1. Modification of Non-Metallic Inclusions by Rare-Earth Elements in Microalloyed Steels

    Directory of Open Access Journals (Sweden)

    M. Opiela

    2012-04-01

    Full Text Available The modification of the chemical composition of non-metallic inclusions by rare-earth elements in the new-developed microalloyed steels was discussed in the paper. The investigated steels are assigned to production of forged elements by thermo- mechanical treatment. The steels were melted in a vaccum induction furnace and modification of non-metallic inclusions was carried out by the michmetal in the amount of 2.0 g per 1 kg of steel. It was found that using material charge of high purity and a realization of metallurgical process in vacuous conditions result in a low concentration of sulfur (0.004%, phosphorus (from 0.006 to 0.008% and oxygen (6 ppm. The high metallurgical purity is confirmed by a small fraction of non-metallic inclusions averaging 0.075%. A large majority of non-metallic inclusions are fine, globular oxide-sulfide or sulfide particles with a mean size 17m2. The chemical composition and morphology of non-metallic inclusions was modified by Ce, La and Nd, what results a small deformability of non- metallic inclusions during hot-working.

  2. EDITORIAL: Charge transport in non-metallic solids

    Science.gov (United States)

    Youngs, Ian J.; Almond, Darryl P.

    2009-03-01

    Workers engaged in a wide range of investigations of charge transport in non-metallic solids came together at a meeting of the Institute of Physics Dielectric Group, held in London on 2 April 2008. Topics included both ionic and electronic conduction, investigations of the fundamental mechanisms of charge transport, percolation, modelling the conduction process in both natural and man-made composite electrical and electromagnetic materials, the design and development of solids with specified conduction properties and the ac characteristics of non-metallic solids. In the first session, the long-standing problem of the anomalous power law increase in ac conductivity with frequency was addressed by a set of four presentations. Jeppe Dyre, an invited speaker from Roskilde University, Denmark, introduced the problem and stressed the universality of the frequency dependence observed in the ac conductivities of disordered non-metallic materials. He showed that it could be obtained from a simple random barrier model, independent of the barrier distribution. Darryl Almond, University of Bath, showed that the electrical responses of large networks of randomly positioned resistors and capacitors, simulating the microstructures of disordered two-phase (conductor insulator) materials, exhibit the same frequency dependence. He demonstrated their robustness to component value and distribution and suggested that it was an emergent property of these networks and of two-phase materials. Klaus Funke, an invited speaker from the University of Munster, Germany, presented a detailed model of ion motion in disordered ionic materials. He stressed the need to account for the concerted many-particle processes that occur whilst ions hop from site to site in response to an applied electric field. The conductivity spectra obtained from this work reproduce the same frequency dispersion and have the additional feature of conductivity saturation at high frequencies. Tony West, University of

  3. Alterations in a Unique Class of Cortical Chandelier Cell Axon Cartridges in Schizophrenia.

    Science.gov (United States)

    Rocco, Brad R; DeDionisio, Adam M; Lewis, David A; Fish, Kenneth N

    2017-07-01

    The axons of chandelier cells (ChCs) target the axon initial segment of pyramidal neurons, forming an array of boutons termed a cartridge. In schizophrenia, the density of cartridges detectable by gamma-aminobutyric acid (GABA) membrane transporter 1 immunoreactivity is lower, whereas the density of axon initial segments detectable by immunoreactivity for the α2 subunit of the GABA A receptor is higher in layers 2/superficial 3 of the prefrontal cortex. These findings were interpreted as compensatory responses to lower GABA levels in ChCs. However, we recently found that in schizophrenia, ChC cartridge boutons contain normal levels of the 67 kDa isoform of glutamic acid decarboxylase (GAD67) protein, the enzyme responsible for GABA synthesis in these boutons. To understand these findings we quantified the densities of ChC cartridges immunoreactive for vesicular GABA transporter (vGAT+), which is present in all cartridge boutons, and the subset of cartridges that contain calbindin (CB+). Prefrontal cortex tissue sections from 20 matched pairs of schizophrenia and unaffected comparison subjects were immunolabeled for vGAT, GAD67, and CB. The mean density of vGAT+/CB+ cartridges was 2.7-fold higher, exclusively in layer 2 of schizophrenia subjects, whereas the density of vGAT+/CB- cartridges did not differ between subject groups. Neither vGAT, CB, or GAD67 protein levels per ChC bouton nor the number of boutons per cartridge differed between subject groups. Our findings of a greater density of CB+ ChC cartridges in prefrontal cortex layer 2 from schizophrenia subjects suggests that the normal developmental pruning of these cartridges is blunted in the illness. Copyright © 2016 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  4. Treatment of transverse patellar fractures: a comparison between metallic and non-metallic implants.

    Science.gov (United States)

    Heusinkveld, Maarten H G; den Hamer, Anniek; Traa, Willeke A; Oomen, Pim J A; Maffulli, Nicola

    2013-01-01

    Several methods of transverse patellar fixation have been described. This study compares the clinical outcome and the occurrence of complications of various fixation methods. The databases PubMed, Web of Science, Science Direct, Google Scholar and Google were searched. A direct comparison between fixation techniques using mixed or non-metallic implants and metallic K-wire and tension band fixation shows no significant difference in clinical outcome between both groups. Additionally, studies reporting novel operation techniques show good clinical results. Studies describing the treatment of patients using non-metallic or mixed implants are fewer compared with those using metallic fixation. A large variety of clinical scoring systems were used for assessing the results of treatment, which makes direct comparison difficult. More data of fracture treatment using non-metallic or mixed implants is needed to achieve a more balanced comparison.

  5. Modelling of non-metallic particles motion process in foundry alloys

    Directory of Open Access Journals (Sweden)

    P. L. Żak

    2015-04-01

    Full Text Available The behaviour of non-metallic particles in the selected composites was analysed, in the current study. The calculations of particles floating in liquids differing in viscosity were performed. Simulations based on the Stokes equation were made for spherical SiC particles and additionally the particle size influence on Reynolds number was analysed.The movement of the particles in the liquid metal matrix is strictly connected with the agglomerate formation problem.Some of collisions between non-metallic particles lead to a permanent connection between them. Creation of the two spherical particles and a metallic phase system generates the adhesion force. It was found that the adhesion force mainly depends on the surface tension of the liquid alloy and radius of non-metallic particles.

  6. Regularities of Filamentary Channels Formation During Formation of Nanostructured Non-Metallic Inorganic Coatings in Microplasma Galvanostatic Mode in Solutions

    Science.gov (United States)

    Mamaev, A. I.; Mamaeva, V. A.; Kolenchin, N. F.; Chubenko, A. K.; Kovalskaya, Ya. B.; Konstantinova, T. A.; Dolgova, Yu. N.; Beletskaya, E. Yu.

    2016-04-01

    This paper presents the theoretical models describing the growth of filamentary channels of nanostructured non-metallic coatings formed by anodizing and microplasma oxidation. The authors identified dependences of the number of pores on the coating thickness. The paper presents graphic dependences of the number of filamentary channels on the process time and the coating thickness. These dependences allow calculating through and surface porosity, and in cases, when the pores are filled with functional material, they allow calculating the concentration distribution of this functional material throughout the coating thickness. The theoretical models enhance our understanding of the nature of anode processes and can be used to describe and forecast the growth and filling of porous coatings, so they can also be used to create functional and bioactive materials.

  7. A new non-metallic anchorage system for post-tensioning applications using CFRP tendons

    Science.gov (United States)

    Taha, Mahmoud Reda

    The objective of the work described in this thesis is to design, develop and test a new non-metallic anchorage system for post-tensioning applications using CFRP tendons. The use of a non-metallic anchorage system should eliminate corrosion and deterioration concerns in the anchorage zone. The development of a reliable non-metallic anchorage would provide an important contribution to this field of knowledge. The idea of the new anchorage is to hold the tendon through mechanical gripping. The anchorage consists of a barrel with a conical housing and four wedges. The anchorage components are made of ultra high performance concrete (UHPC) specially developed for the anchorage. Sixteen concrete mixtures with different casting and curing regimes were examined to develop four UHPC mixtures with compressive strengths in excess of 200 MPa. The UHPC mixtures showed very dense microstructures with some unique characteristics. To enhance the fracture toughness of the newly developed UHPC, analytical and experimental analyses were performed. Using 3 mm chopped carbon fibres, a significant increase in the fracture toughness of UHPC was achieved. The non-metallic anchorage was developed with the UHPC with enhanced fracture toughness. The barrel required careful wrapping with CFRP sheets to provide the confinement required to utilize the strength and toughness of the UHPC. Thirty-three anchorages were tested under both static and dynamic loading conditions. The non-metallic anchorage showed excellent mechanical performance and fulfilled the different requirements of a post-tensioning anchorage system. The development of the new non-metallic anchorage will widen the inclusion of CFRP tendons in post-tensioned concrete/masonry structures. The new system will offer the opportunity to exploit CFRP tendons effectively creating an innovative generation of corrosion-free, smart structures.

  8. 42 CFR 84.1155 - Filters used with canisters and cartridges; location; replacement.

    Science.gov (United States)

    2010-10-01

    ...; location; replacement. 84.1155 Section 84.1155 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH... Efficiency Respirators and Combination Gas Masks § 84.1155 Filters used with canisters and cartridges; location; replacement. (a) Particulate matter filters used in conjunction with a canister or cartridge...

  9. The Effect of Different Non-Metallic Inclusions on the Machinability of Steels.

    Science.gov (United States)

    Ånmark, Niclas; Karasev, Andrey; Jönsson, Pär Göran

    2015-02-16

    Considerable research has been conducted over recent decades on the role of non‑metallic inclusions and their link to the machinability of different steels. The present work reviews the mechanisms of steel fractures during different mechanical machining operations and the behavior of various non-metallic inclusions in a cutting zone. More specifically, the effects of composition, size, number and morphology of inclusions on machinability factors (such as cutting tool wear, power consumption, etc .) are discussed and summarized. Finally, some methods for modification of non-metallic inclusions in the liquid steel are considered to obtain a desired balance between mechanical properties and machinability of various steel grades.

  10. ULC/ORD-C80.1 : the standard for aboveground non-metallic tanks for fuel oil

    Energy Technology Data Exchange (ETDEWEB)

    Nikolic, G. [Underwriters' Lab. of Canada, Toronto, ON (Canada)

    2001-09-01

    As a rule, flammable and combustible liquids were stored in aboveground tanks made of steel. Non-metallic materials are now being used for a new generation of aboveground tanks. Corrosion is a problem faced by most tank owners in many parts of Canada. Saltwater mist, sand blasting and bacteria growth formed in the condensation water at the bottom of the tank in the Maritimes affects an aboveground tank installed outdoors and close to the seashore. European non-metallic aboveground tanks for fuel oil first arrived on the North American market, and are now followed by designs from Canada. Requirements for these tanks were developed and tested by the Underwriters' Laboratories of Canada (ULC). It is a not-for-profit, independent organization accredited by the Standards Council of Canada to perform safety, certification, testing, quality registration, and standards development. The minimum criteria for non-metallic aboveground tank construction are contained in the ULC/ORD-C80.1 document. They can be constructed of fiber-reinforced plastic (FRP), single or double wall, or they can be double wall tanks consisting of primary plastic tanks within metallic secondary containment. Other tanks are made of the blow molded high-density polyethylene. To simulate an in-house installation, fire tests were performed where a tank filled with fuel was exposed to pool fire for 30 minutes. A successful test meant the tank had not ruptured nor leaked during and after the test. Testers had to observe that any collapse occurred above the liquid level, and that violent explosion of any part of the tank or its content did not occur. The design requirements were evaluated by performing an analysis of the temperature chart: maximum vapour temperature inside the tank was 358 Celsius, while the liquid reached a maximum temperature of 91 Celsius and the outside temperature reached 600 Celsius. Primary tank pressure did not exceed 17 kilo Pascal. Building simulation of venting installation

  11. CSER 95-014: Criticality storage category for K Basin spent cartridge filters in ECOROK casks at central waste complex

    International Nuclear Information System (INIS)

    Miller, E.M.

    1996-01-01

    This CSER justifies storing K Basin spent cartridge filters in ECOROK 25-11 casks with liners under the limits in an existing criticality prevention specification, CPS-SW-149-00002, Rev./Mod. B-1, because the worst case fissionable material inventory is less then 1/2 the CPS limit and the cask is larger than allowed containers, the cask and liner have adequate iron content to meet the CPS requirements, and the cask concrete walls are thick enough to isolate the fissionable contents of each cask from neutron interaction with fissionable material external to each cask

  12. Economic assessment of using nonmetallic materials in the direct utilization of geothermal energy. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Cabibbo, S.V.; Ammerlaan, T.

    1979-02-01

    The cost effectiveness of nonmetallic materials in three direct-use geothermal applications was assessed. An extensive review of the available literature was conducted in order to ascertain those processes for which sufficient design and cost data had been published to permit this economic assessment to be made. Only three such processes could be found and they are discussed.

  13. Soil effects on GPR detection of buried non-metallic mines

    NARCIS (Netherlands)

    Hendrickx, J.M.H.; Hong, S.H.; Miller, T.; Borchers, B.; Rhebergen, J.B.

    2003-01-01

    Landmines are a major problem in many areas of the world. In spite of the fact that many different types of landmine sensors have been developed, the detection of non-metallic landmines remains very difficult. The objective of this contribution is to synthesize our work related to the effects of

  14. Evaluation and comparison of a national made dental cartridge with two foreign made

    Directory of Open Access Journals (Sweden)

    Mahmood Hashemi H

    2006-06-01

    Full Text Available Background and Aim: Several factories produce dental cartridge in the world. In Iran, Daroupakhsh company is responsible for this task. The aim of this study was evaluate some properties of daroupakhsh cartridge and compare them with two imported ones: Ecocaine (made in Italy and Septodont (made in France. Materials and Methods: In this experimental study, 70 healthy patients from maxillofacial clinic of Shariaty hospital were selected. After obtaining informed consent, 0.1 cc of each carpule was injected to the patients' frontal region and the extent of anesthesia was measured at different time intervals. Also the quality of injections was evaluated by 11 surgeons. The dimensions of the three cartridges were also measured and compared together. Data were analyzed by repeated measure ANOVA and Friedman with p<0.05 as the limit of significance. Results: There was no significant difference in extent and duration of anesthesia among the studied cartridges. Surgeons were equally satisfied of all three kinds of cartridges. All of the cartridges were aspirable. Conclusion: Based on the results of this study, the three studied cartridges had similar properties.

  15. Autoradiographic investigation of the removal of non-metallic inclusions in connection with the steel remelting process in vacuum furnaces

    International Nuclear Information System (INIS)

    Kolaski, H.; Siewierski, J.

    1978-01-01

    The labelled radioactive non-metallic inclusions in steel were obtained through deoxidation of steel with an activated aluminium alloy containing 1% rare earths. Quantity and distribution of the non-metallic inclusions in the steel were determined by applying autoradiography to the longitudinal and cross sections of the steel slabs. After remelting in an electronic furnace the distribution of non-metallic inclusions was determined by autoradiography of the lateral surfaces and the cross section of the slabs. It was found that 50 - 70% of the inclusions could be removed. The results obtained from autoradiographic investigation allow the exploration of the mechanism of the removal of inclusions. (author)

  16. Nanoparticle separation with a miniaturized asymmetrical flow field-flow fractionation cartridge

    Science.gov (United States)

    Müller, David; Cattaneo, Stefano; Meier, Florian; Welz, Roland; deMello, Andrew

    2015-07-01

    Asymmetrical Flow Field-Flow Fractionation (AF4) is a separation technique applicable to particles over a wide size range. Despite the many advantages of AF4, its adoption in routine particle analysis is somewhat limited by the large footprint of currently available separation cartridges, extended analysis times and significant solvent consumption. To address these issues, we describe the fabrication and characterization of miniaturized AF4 cartridges. Key features of the scale-down platform include simplified cartridge and reagent handling, reduced analysis costs and higher throughput capacities. The separation performance of the miniaturized cartridge is assessed using certified gold and silver nanoparticle standards. Analysis of gold nanoparticle populations indicates shorter analysis times and increased sensitivity compared to conventional AF4 separation schemes. Moreover, nanoparticulate titanium dioxide populations exhibiting broad size distributions are analyzed in a rapid and efficient manner. Finally, the repeatability and reproducibility of the miniaturized platform are investigated with respect to analysis time and separation efficiency.

  17. EPA Region 8, Memo on Desktop Printer Ink Cartridges Policy & Voluntary Printer Turn-in

    Science.gov (United States)

    This memo requests EPA Region 8 users to voluntarily turn-in their desktop printers and notifies users of the Region 8 policy to not provide maintenance or ink and toner cartridges for desktop printers.

  18. The indicating FTA elute cartridge a solid sample carrier to detect high-risk HPV and high-grade cervical lesions

    NARCIS (Netherlands)

    Bie, R.P. de; Schmeink, C.E.; Bakkers, J.M.J.E.; Snijders, P.J.L.M.; Quint, W.G.V.; Massuger, L.F.A.G.; Bekkers, R.L.M.; Melchers, W.J.G.

    2011-01-01

    The clinically validated high-risk human papillomavirus (hrHPV) Hybrid Capture 2 (HC2) and GP5+/6+-PCR assays were analyzed on an Indicating FTA Elute cartridge (FTA cartridge). The FTA cartridge is a solid dry carrier that allows safe transport of cervical samples. FTA cartridge samples were

  19. Performance simulation of serpentine type metallic and non-metallic solar collector

    International Nuclear Information System (INIS)

    Al-Sageer, A. A. M.; Alowa, M. I.; Saad, M.

    2006-01-01

    This paper presents a theoretical investigation of metallic and non-metalic solar water collector models for evaluating its performane parameters. The determined parameters include heat removal factor , overall heat loss coefficients, heat gain, daily and hourly efficiencies. The present study reports that, under forced circulation lest, the non-metallic collector has an inferior performance parameters when compared to that of the metallic one. It was also revealed that the overall heat loss coefficients of both collectors show weak dependence on the flow rate variations. It was also noticed that the heat removal factor forboth models is more sensitive to the flow rate variations. Also noticed that the heat removal factor for both models is more sensitive to the flow rate variations. Also, a comparision of performance parameters of the theoretical and experimental studies showed good agreements for most hours of the day, except the results obtained at the early morning and late after noon hours.(Author)

  20. Computer Simulation of the Formation of Non-Metallic Precipitates During a Continuous Casting of Steel

    Directory of Open Access Journals (Sweden)

    Kalisz D.

    2016-03-01

    Full Text Available The authors own computer software, based on the Ueshima mathematical model with taking into account the back diffusion, determined from the Wołczyński equation, was developed for simulation calculations. The applied calculation procedure allowed to determine the chemical composition of the non-metallic phase in steel deoxidised by means of Mn, Si and Al, at the given cooling rate. The calculation results were confirmed by the analysis of samples taken from the determined areas of the cast ingot. This indicates that the developed computer software can be applied for designing the steel casting process of the strictly determined chemical composition and for obtaining the required non-metallic precipitates.

  1. Influence of crystallization conditions on formation and distribution of nonmetallic inclusions in steels

    International Nuclear Information System (INIS)

    Efimov, V.A.

    1977-01-01

    The processes were studied of the formation and the distribution of nonmetallic inclusions and the chemical inhomogeneity formation during the solidification of h steel. The variation of the character of oxides and sulfides across ingots was shown by considering st 25 and 20 Kh steels. To improve the distribution of inclusions and the stability of properties throughout the body of ingots, it is recommended to throughly deoxidize the metal, to raise the rate of solidification, to reduce the temperature gradient, to employ powder cooling agents, to use casting under a blanket of slag, to modify steel by active elements (r.e.e., Ca, Ba, Zr, B) which affect favourably the nature and the shape of the nonmetallic phase

  2. Application of Different Extraction Methods for Investigation of Nonmetallic Inclusions and Clusters in Steels and Alloys

    Directory of Open Access Journals (Sweden)

    Diana Janis

    2014-01-01

    Full Text Available The characterization of nonmetallic inclusions is of importance for the production of clean steel in order to improve the mechanical properties. In this respect, a three-dimensional (3D investigation is considered to be useful for an accurate evaluation of size, number, morphology of inclusions, and elementary distribution in each inclusion particle. In this study, the application of various extraction methods (chemical extraction/etching by acid or halogen-alcohol solutions, electrolysis, sputtering with glow discharge, and so on for 3D estimation of nonmetallic Al2O3 inclusions and clusters in high-alloyed steels was examined and discussed using an Fe-10 mass% Ni alloy and an 18/8 stainless steel deoxidized with Al. Advantages and limitations of different extraction methods for 3D investigations of inclusions and clusters were discussed in comparison to conventional two-dimensional (2D observations on a polished cross section of metal samples.

  3. Injury experience in nonmetallic mineral mining (except stone and coal), 1991

    Energy Technology Data Exchange (ETDEWEB)

    1993-10-01

    This Mine Safety and Health Administration (MSHA) informational report reviews in detail the occupational injury and illness experience of nonmetallic mineral mining (except stone and coal) in the United States for 1991. Data reported by operators of mining establishments concerning work injuries are summarized by work location, accident classification, part of body injured, nature of injury, occupation, and principal type of mineral. Related information on employment, worktime, and operating activity also is presented. Data reported by independent contractors performing certain work at mining locations are depicted separately in this report. For ease of comparison with other metal and nonmetallic mineral mining industries and with coal mining, summary reference tabulations are included at the end of both the operator and the contractor sections of this report.

  4. Non-metallic implant for patellar fracture fixation: A systematic review.

    Science.gov (United States)

    Camarda, Lawrence; Morello, Salvatore; Balistreri, Francesco; D'Arienzo, Antonio; D'Arienzo, Michele

    2016-08-01

    Despite good clinical outcome proposals, there has been relatively little published regarding the use of non-metallic implant for patellar fracture fixation. The purpose of the study was to perform a systematic literature review to summarize and evaluate the clinical studies that described techniques for treating patella fractures using non-metallic implants. A comprehensive literature search was systematically performed to evaluate all studies included in the literature until November 2015. The following search terms were used: patellar fracture, patella suture, patella absorbable, patella screw, patella cerclage. Two investigators independently reviewed all abstracts and the selection of these abstracts was then performed based on inclusion and/or exclusion criteria. A total of 9 studies involving 123 patients were included. Patients had a mean age of 33.7 years and were followed up for a mean of 18.9 months. The most common method for fracture fixations included the use of suture material. Good clinical outcomes were reported among all studies. Thirteen patients (10.5%) presented complications, while 4 patients (3.2%) required additional surgery for implant removal. There is a paucity of literature focused on the use of non-metallic implant for patellar fracture fixation. However, this systematic review showed that non-metallic implants are able to deliver good clinical outcomes reducing the rate of surgical complications and re-operation. These results may assist surgeons in choosing to use alternative material such as sutures to incorporate into their routine practice or to consider it, in order to reduce the rate of re-operation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Formation of non-metallic inclusions and the possibility of their removal during ingot casting

    OpenAIRE

    Ragnarsson, Lars

    2010-01-01

    The present study was carried out to investigate the formation and evolution of non-metallic inclusions during ingot casting. Emphasize have been on understanding the types of inclusions formed and developed through the casting process and on the development of already existing inclusions carried over from the ladle during casting. Industrial experiments carried on at Uddeholm Tooling together with laboratory work and Computational Fluid Dynamics (CFD) simulations. Ingots of 5.8 tons have bee...

  6. Formation and Chemical Development of Non-metallic Inclusions in Ladle Treatment of Steel

    OpenAIRE

    Beskow, Kristina

    2003-01-01

    The present study was carried out to investigate theformation and chemical development of non-metallic inclusionsduring ladle treatment of steel. To begin with, an investigation of the deoxidation processand the impact of aluminium addition was carried out. For thispurpose, a new experimental setup was constructed. The setupallowed the examination of the deoxidation process as afunction of time by using a quenching technique. Preliminaryexperiments showed that homogeneous nucleation of alumin...

  7. Thermophysical Properties of Matter - the TPRC Data Series. Volume 13. Thermal Expansion - Nonmetallic Solids

    Science.gov (United States)

    1977-01-01

    topography of the state of knowledge on the thermal expansion of nonmetallic solids. We believe there is also much food for reflec- West Lafayette...34 Lithium Silicates ......... 713 209 Magnesium Metasilicate MgSiO. .. ......... 715 210 Magnesium Orthosilicate Mg2 SiO . . . . . . . . . . . . 718 211...Antiferromagnetism of Praseodymium," Phys. Rev. Letters, 12(20), 553-5, 1964. 66. Goode, J.M., "Phase Transition Temperature of Polonium ,"J. Chem. Phys., 26(5), 1269

  8. Implementation of a Non-Metallic Barrier in an Electric Motor

    Science.gov (United States)

    M?Sadoques, George; Carra, Michael; Beringer, Woody

    2012-01-01

    Electric motors that run in pure oxygen must be sealed, or "canned," for safety reasons to prevent the oxygen from entering into the electrical portion of the motor. The current canning process involves designing a metallic barrier around the rotor to provide the separation. This metallic barrier reduces the motor efficiency as speed is increased. In higher-speed electric motors, efficiency is greatly improved if a very thin, nonmetallic barrier can be utilized. The barrier thickness needs to be approximately 0.025-in. (.0.6-mm) thick and can be made of a brittle material such as glass. The motors, however, designed for space applications are typically subject to high-vibration environments. A fragile, non-metallic barrier can be utilized in a motor assembly if held in place by a set of standard rubber O-ring seals. The O-rings provide the necessary sealing to keep oxygen away from the electrical portion of the motor and also isolate the fragile barrier from the harsh motor vibration environment. The compliance of the rubber O-rings gently constrains the fragile barrier and isolates it from the harsh external motor environment. The use of a non-metallic barrier greatly improves motor performance, especially at higher speeds, while isolating the electronics from the working fluid with an inert liner.

  9. A self-contained fully-enclosed microfluidic cartridge for lab on a chip.

    Science.gov (United States)

    Yobas, Levent; Cheow, Lih Feng; Tang, Kum-Cheong; Yong, Shien-Eit; Ong, Eleana Kye-Zheng; Wong, Lionel; Teo, William Cheng-Yong; Ji, Hongmiao; Rafeah, Siti; Yu, Chen

    2009-12-01

    We describe a self-contained fully-enclosed cartridge for lab-on-a-chip applications where sample and reagents can be applied sequentially as is performed in a heterogeneous immunoassay, or nucleic acid extraction. Both the self-contained and fully-enclosed features of the cartridge are sought to ensure its safe use in the field by unskilled staff. Simplicity in cartridge design and operation is obtained via adopting a valveless concept whereby reagents are stored and used in the form of liquid plugs isolated by air spacers around a fluidic loop. Functional components integrated in the loop include a microfluidic chip specific to the target application, a novel peristaltic pump to displace the liquid plugs, and a pair of removable tubing segments where one is used to introduce biological sample and while the other is to collect eluant. The novel pump is fabricated through soft-lithography technique and works by pinching a planar channel under stainless-steel ball bearings that have been magnetically loaded. The utility of the cartridge is demonstrated for automated extraction and purification of nucleic acids (DNA) from a cell lysate on a battery-operated portable system. The cartridge shown here can be further extended to sample-in-answer-out diagnostic tests.

  10. Microfluidic cartridges for DNA purification and genotyping processed in standard laboratory instruments

    Science.gov (United States)

    Focke, Maximilian; Mark, Daniel; Stumpf, Fabian; Müller, Martina; Roth, Günter; Zengerle, Roland; von Stetten, Felix

    2011-06-01

    Two microfluidic cartridges intended for upgrading standard laboratory instruments with automated liquid handling capability by use of centrifugal forces are presented. The first microfluidic cartridge enables purification of DNA from human whole blood and is operated in a standard laboratory centrifuge. The second microfluidic catridge enables genotyping of pathogens by geometrically multiplexed real-time PCR. It is operated in a slightly modified off-the-shelf thermal cycler. Both solutions aim at smart and cost-efficient ways to automate work flows in laboratories. The DNA purification cartridge automates all liquid handling steps starting from a lysed blood sample to PCR ready DNA. The cartridge contains two manually crushable glass ampoules with liquid reagents. The DNA yield extracted from a 32 μl blood sample is 192 +/- 30 ng which corresponds to 53 +/- 8% of a reference extraction. The genotyping cartridge is applied to analyse isolates of the multi-resistant Staphyloccus aureus (MRSA) by real-time PCR. The wells contain pre-stored dry reagents such as primers and probes. Evaluation of the system with 44 genotyping assays showed a 100% specificity and agreement with the reference assays in standard tubes. The lower limit of detection was well below 10 copies of DNA per reaction.

  11. Batch fabrication of polymer microfluidic cartridges for QCM sensor packaging by direct bonding

    Science.gov (United States)

    Sandström, Niklas; Zandi Shafagh, Reza; Gylfason, Kristinn B.; Haraldsson, Tommy; van der Wijngaart, Wouter

    2017-12-01

    Quartz crystal microbalance (QCM) sensing is an established technique commonly used in laboratory based life-science applications. However, the relatively complex, multi-part design and multi-step fabrication and assembly of state-of-the-art QCM cartridges make them unsuited for disposable applications such as point-of-care (PoC) diagnostics. In this work, we present the uncomplicated manufacturing of QCMs in polymer microfluidic cartridges. Our novel approach comprises two key innovations: the batch reaction injection molding of microfluidic parts; and the integration of the cartridge components by direct, unassisted bonding. We demonstrate molding of batches of 12 off-stoichiometry thiol-ene epoxy polymer (OSTE+) polymer parts in a single molding cycle using an adapted reaction injection molding process; and the direct bonding of the OSTE+  parts to other OSTE+  substrates, to printed circuit boards, and to QCMs. The microfluidic QCM OSTE+  cartridges were successfully evaluated in terms of liquid sealing as well as electrical properties, and the sensor performance characteristics are on par with those of a commercially available QCM biosensor cartridge. The simplified manufacturing of QCM sensors with maintained performance potentializes novel application areas, e.g. as disposable devices in a point of care setting. Moreover, our results can be extended to simplifying the fabrication of other microfluidic devices with multiple heterogeneously integrated components.

  12. Hazard classification test of the cartridge, 120-mm, APFSDS-T, XM829

    Energy Technology Data Exchange (ETDEWEB)

    Hooker, C.D.; Hadlock, D.E.; Mishima, J.; Gilchrist, R.L.

    1983-11-01

    Research was conducted to determine the behavior of the ammunition XM829 when subjected to detonation of an adjacent XM829 cartridge, and a sustained hot fire. It was concluded that the functioning of an XM829 cartridge, in one shipping container, will not cause immediate functioning of XM829 cartridges in adjacent containers. However, if a fire results and is sustained, adjacent cartridges may ignite, resulting in some scattering of debris within a maximum radius of 40 feet. Further, the XM829 cartridge can be expected to remain in a kinetic controlled regime with vigorous oxidation occurring early in such a fire but dropping off as the temperature cools toward ambient. Mass balance analyses data indicated a recovery of at least 80% in the 1982 external heat; in the 1983 test, the recovery percentage was improved to approximately 100% of the original depleted uranium weight volume. Therefore, it may be concluded that a significant airborne release of the depleted uranium material did not occur.

  13. The isolation of water-soluble radionuclides from deteriorating spent nuclear fuel in zeolite cartridge

    International Nuclear Information System (INIS)

    Hassan, N.M.; Thompson, M.C.

    1996-01-01

    A method of isolating water-soluble radionuclides leaching from deteriorating spent nuclear fuel by ion-exchange in zeolite cartridges has been studied. Design calculations of two zeolite cartridges to be incorporated in typical spent fuel storage bundle have been provided. Equilibrium exchange data obtained at several temperatures have shown that the maximum exchange capacity of total cesium in sodium titanium aluminosilicate was 114 mg/g zeolite and the capacity at 95% exchange for radioactive isotope Cs-137 was calculated as 55.2 mg/g zeolite. The kinetic data suggest that the rate of exchange of Cs + in sodium titanium aluminosilicate zeolite takes place by a fast initial exchange step followed by slow diffusion of cesium cations. Design calculations based on the equilibrium exchange data show that water-soluble radionuclides leaching from Mk 31 slugs can be isolated using two zeolite cartridges, each 3.7 inches in inside diameter and 2.5 inches in length. The cartridges are designed to isolate 95% of the Cs + leaching from the spent fuel storage bundle. The results from the thermal induced convective flow tests indicate that the system will provide necessary cooling to the spent fuel by convective currents while isolating the Cs + leaching from spent fuel storage bundle in the cartridges

  14. Comparison of a gel column blood typing method and a point-of-care cartridge for dog erythrocyte antigen 1.1.

    Science.gov (United States)

    Blois, Shauna L; Richardson, Danielle M; Abrams-Ogg, Anthony C G

    2013-01-01

    Blood typing for the presence of Dog Erythrocyte Antigen (DEA) 1.1 is recommended in all donor and recipient dogs prior to transfusion of blood products. The objective of this study was to determine if a point-of-care DEA 1.1 blood typing cartridge could be used in place of the gel column typing method. Detection of DEA 1.1 was performed using a laboratory-based gel column method and a point-of-care cartridge. A convenience sample of 30 healthy blood donors, 13 dogs with immune-mediated hemolytic anemia (IMHA) (3 of which had concurrent immune-mediated thrombocytopenia [IMT]), and 44 dogs with other diseases was included in the study. Agreement was observed between the tests for normal dogs and dogs with nonimmune-mediated disease in 74/74 cases. Two dogs in the IMHA group had indeterminate gel column blood typing results; 1 dog in this group had a negative gel column test result but a positive cartridge test result. There was good agreement between the 2 methods for normal dogs and dogs with nonimmune-mediated disease. Blood typing methods in dogs with IMHA should be further investigated. © Veterinary Emergency and Critical Care Society 2013.

  15. [Acrylic resin reinforcement with metallic and nonmetallic inserts].

    Science.gov (United States)

    Preoteasa, Elena; Murariu, Cătălina Măgureanu; Ionescu, Ecaterina; Preoteasa, Cristina Teodora

    2007-01-01

    In the current use of acrylic resin for removable dentures and orthodontic treatments we are frequently facing the fact of base fracture. The repairing of this, determine most of the time, discomfort of the patient, by excluding the prosthetic device, affecting the treatment, loosing patient's time, doctor's time, implying the dental laboratory and extra expenses. The causes of fractures are many, from clinical cases with some specific anatomic and functional particularities, or parafunctional, to the incorrect designing, manufacturing or wearing of the prosthetic part, being connected with the materials characteristics. The consequences and costs of these fractures are leading to unsatisfying results in some of the clinical cases, in presence of parafunctions like bruxism or clenching and specifically for the new types of prosthetic rehabilitation, on natural teeth or implants.

  16. Fluid Force-Induced Detachment Criteria for Nonmetallic Inclusions Adhered to a Refractory/Molten Steel Interface

    Science.gov (United States)

    Dieguez Salgado, Uxia; Weiß, Christian; Michelic, Susanne K.; Bernhard, Christian

    2018-05-01

    Since nonmetallic inclusions (NMIs) in steel cannot be completely avoided, a greater understanding of their development and evolution during the steelmaking process is required. In particular, this includes the adhesion of microinclusions to the refractory/steel interface in the flow control system between the tundish and the mold. This phenomenon, commonly referred to as clogging, causes losses in productivity and product quality. Inclusions transported from the bulk melt to the boundary layer may adhere to the refractory/steel interface due to formation of a fluid cavity. A detailed model was derived for the detachment of NMIs adhering to a nozzle wall and is based on the local hydrodynamic conditions combined with the specific interfacial properties in the system consisting of the inclusions, the refractories, and the steel. The model is evaluated for three different application-oriented cases. This study has been focused on providing a better understanding of fluid flow in the near-wall region in order to reduce clogging during steelmaking.

  17. Non-metallic nanomaterials in cancer theranostics: a review of silica- and carbon-based drug delivery systems

    International Nuclear Information System (INIS)

    Chen, Yu-Cheng; Huang, Xin-Chun; Luo, Yun-Ling; Chang, Yung-Chen; Hsieh, You-Zung; Hsu, Hsin-Yun

    2013-01-01

    The rapid development in nanomaterials has brought great opportunities to cancer theranostics, which aims to combine diagnostics and therapy for cancer treatment and thereby improve the healthcare of patients. In this review we focus on the recent progress of several cancer theranostic strategies using mesoporous silica nanoparticles and carbon-based nanomaterials. Silicon and carbon are both group IV elements; they have been the most abundant and significant non-metallic substances in human life. Their intrinsic physical/chemical properties are of critical importance in the fabrication of multifunctional drug delivery systems. Responsive nanocarriers constructed using these nanomaterials have been promising in cancer-specific theranostics during the past decade. In all cases, either a controlled texture or the chemical functionalization is coupled with adaptive properties, such as pH-, light-, redox- and magnetic field- triggered responses. Several studies in cells and mice models have implied their underlying therapeutic efficacy; however, detailed and long-term in vivo clinical evaluations are certainly required to make these bench-made materials compatible in real bedside circumstances. (review)

  18. Validation of a cartridge method for the quality control determination of 99Tcm-HMPAO

    International Nuclear Information System (INIS)

    Pandos, G.; Penglis, S.; Tsopelas, C.; Royal Adelaide Hospital, Adelaide, SA

    1999-01-01

    Full text: The manufacturer's method for assessing the radiochemical purity (RCP) of ±-HMPAO requires the use of three solvent types on two different stationary phases, and is time-consuming (∼ 15 min) in consideration of the short shelf-life (30 min). An impetus to develop a rapid quality control procedure for this product has led to the use of a single strip Whatman 17 chromatography system using ethyl acetate as the developing solvent. This popular Whatman paper system was previously validates against the manufacturer's method. We have developed a new method to successfully determine the % RCP of ±-HMPAO, which employs a disposable, inexpensive and reusable Amprep C-18 cartridge with normal saline as a non-organic mobile phase. The Whatman paper system separates the primary lipophilic 99 Tc m -HMPAO complex from 99 Tc m O-2, 99 Tc m O 4 and secondary 99 Tc m -HMPAO complex at the origin. By comparison, the lipophilic portion was retained on the cartridge and the hydrophilic impurities were found in saline eluent with the cartridge method. Whatman 17 paper system results showed 95.1 ± I.7% 99 Tc m -HMPAO after 5 min and the cartridge method gave 95.5 ± 1.5% 99 Tc m -HMPAO (n = 8) after 3 min. The % 99 Tc m O 2 levels in 99 Tc m -HMPAO were insignificant. When a failed kit was assessed for RCP at 2.5 h post-reconstitution, the Whatman paper system and the cartridge method correlated well, resulting in 63.1 ± 2.7% and 62.9±2.1% 99 Tc m -HMPAO (n=3) respectively. Although the cartridge method may slightly overestimate the % RCP of 99 Tc m -HMPAO, it was found to be simple, rapid and reliable for the quality control analysis of routine 99 Tc m -HMPAO preparations

  19. Individual analysis of nonmetallic Inclusions in Steel by using the gallium focused ion beam secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Tomiyasu, Bunbunoshin; Inami, Akihiro; Abe, Masakazu; Nihei, Yoshimasa.

    1995-01-01

    Nonmetallic inclusions frequently exert a lot of unfavorable influences on the quality of steel. The size of nonmetallic inclusions in current steel products is less than a few μm in diameter. It is desirable to make clear the origin and generation process of such small particles of nonmetallic inclusion. In order to measure the shape, size, composition and inner elemental distribution, development of characterization methods for each inclusion particle is required. By employing a gallium focused ion beam (FIB) as a primary ion beam of secondary ion mass spectrometry (SIMS), the particle analysis with high spatial resolution is easily achieved. In this paper, we present the novel individual analysis of nonmetallic inclusions in steel by gallium FIB SIMS. We analyzed in two ways the nonmetallic inclusion particles segregated by electron beam melting. (1) By cross-sectioning of the particle using a gallium FIB, elemental maps of cross-section were obtained. The elements were distributed inhomogeneously on the cross-section. (2) We carried out the compositional analysis for several particles individually. Ten particles were analyzed by the shave-off analysis and the multivariate cluster analysis. Based on the composition of each particle, the inclusions were classified into six types. (author)

  20. Electricity demand and conservation potential in the Chinese nonmetallic mineral products industry

    International Nuclear Information System (INIS)

    Lin, Boqiang; Ouyang, Xiaoling

    2014-01-01

    As the high energy-consuming manufacturing industry, electricity consumption of nonmetallic mineral products in China accounted for 7.93% of industrial, 5.84% of national and 1.33% of global electricity consumption in 2010. This study attempts to specify the determinants of sectoral electricity demand, forecast future electricity consumption by creating a model using the Johansen cointegration methodology and estimate the sectoral electricity conservation potential. Results indicate that GDP per capita is the leading force explaining the sectoral electricity consumption increase, while value-added per worker, R and D intensity and electricity price are the main factors contributing to the sectoral electricity consumption decrease. Results demonstrate that sectoral electricity consumption in 2020 will be 369.79–464.83 billion kWh under the low-growth scenario and 530.14–666.39 billion kWh under the high-growth scenario. Moreover, under the low-growth scenario, the sectoral electricity conservation potential in 2020 will be 33.72–95.03 billion kWh, accounting for 0.45–1.26% of China's total electricity demand in 2020; under the high-growth scenario, the sectoral electricity conservation potential in 2020 will be 48.34–136.24 billion kWh, accounting for 0.26–0.74% of world's total electricity consumption in 2010 respectively. Finally, we provide some policy recommendations for encouraging energy conservation in China's nonmetallic mineral products industry. - Highlights: • A long-term relationship of electricity demand in nonmetallic minerals industry is established. • Determinants of the sectoral electricity consumption are specified. • The sectoral electricity demand and saving potential are analyzed using scenarios analysis. • Electricity saving potential will be 48.34–136.24 billion kWh under the high-growth scenario

  1. New technology for recovering residual metals from nonmetallic fractions of waste printed circuit boards.

    Science.gov (United States)

    Zhang, Guangwen; He, Yaqun; Wang, Haifeng; Zhang, Tao; Wang, Shuai; Yang, Xing; Xia, Wencheng

    2017-06-01

    Recycling of waste printed circuit boards is important for environmental protection and sustainable resource utilization. Corona electrostatic separation has been widely used to recycle metals from waste printed circuit boards, but it has poor separation efficiency for finer sized fractions. In this study, a new process of vibrated gas-solid fluidized bed was used to recycle residual metals from nonmetallic fractions, which were treated using the corona electrostatic separation technology. The effects of three main parameters, i.e., vibration frequency, superficial air flow velocity, and fluidizing time on gravity segregation, were investigated using a vibrating gas-solid fluidized bed. Each size fraction had its own optimum parameters. Corresponding to their optimal segregation performance, the products from each experiment were analyzed using an X-ray fluorescence (XRF) and a scanning electron microscope (SEM) equipped with an energy dispersive spectrometer (EDS). From the results, it can be seen that the metal recoveries of -1+0.5mm, -0.5+0.25mm, and -0.25mm size fractions were 86.39%, 82.22% and 76.63%, respectively. After separation, each metal content in the -1+0.5 or -0.5+0.25mm size fraction reduced to 1% or less, while the Fe and Cu contents are up to 2.57% and 1.50%, respectively, in the -0.25mm size fraction. Images of the nonmetallic fractions with a size of -0.25mm indicated that a considerable amount of clavate glass fibers existed in these nonmetallic fractions, which may explain why fine particles had the poorest segregation performance. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Measurement of Poisson's ratio of nonmetallic materials by laser holographic interferometry

    Science.gov (United States)

    Zhu, Jian T.

    1991-12-01

    By means of the off-axis collimated plane wave coherent light arrangement and a loading device by pure bending, Poisson's ratio values of CFRP (carbon fiber-reinforced plactics plates, lay-up 0 degree(s), 90 degree(s)), GFRP (glass fiber-reinforced plactics plates, radial direction) and PMMA (polymethyl methacrylate, x, y direction) have been measured. In virtue of this study, the ministry standard for the Ministry of Aeronautical Industry (Testing method for the measurement of Poisson's ratio of non-metallic by laser holographic interferometry) has been published. The measurement process is fast and simple. The measuring results are reliable and accurate.

  3. Microfluidic cartridges for automated, point-of-care blood cell counting

    CSIR Research Space (South Africa)

    Smith, Suzanne

    2016-11-01

    Full Text Available Disposable, low-cost microfluidic cartridges for automated blood cell counting applications are presented in this article. The need for point-of-care medical diagnostic tools is evident, particularly in low-resource and rural settings, and a full...

  4. Optimal stapler cartridge selection according to the thickness of the pancreas in distal pancreatectomy.

    Science.gov (United States)

    Kim, Hongbeom; Jang, Jin-Young; Son, Donghee; Lee, Seungyeoun; Han, Youngmin; Shin, Yong Chan; Kim, Jae Ri; Kwon, Wooil; Kim, Sun-Whe

    2016-08-01

    Stapling is a popular method for stump closure in distal pancreatectomy (DP). However, research on which cartridges are suitable for different pancreatic thickness is lacking. To identify the optimal stapler cartridge choice in DP according to pancreatic thickness.From November 2011 to April 2015, data were prospectively collected from 217 consecutive patients who underwent DP with 3-layer endoscopic staple closure in Seoul National University Hospital, Korea. Postoperative pancreatic fistula (POPF) was graded according to International Study Group on Pancreatic Fistula definitions. Staplers were grouped based on closed length (CL) (Group I: CL ≤ 1.5 mm, II: 1.5 mm 17 mm. With pancreatic thickness <12 mm, the POPF rate was lowest with Group II (I: 50%, II: 27.6%, III: 69.2%, P = 0.035).The optimal stapler cartridges with pancreatic thickness <12 mm were those in Group II (Gold, CL: 1.8 mm). There was no suitable cartridge for thicker pancreases. Further studies are necessary to reduce POPF in thick pancreases.

  5. 3D-Printed Paper Spray Ionization Cartridge with Integrated Desolvation Feature and Ion Optics

    NARCIS (Netherlands)

    Salentijn, G Ij; Oleschuk, R D; Verpoorte, E

    2017-01-01

    In this work we present the application of 3D-printing for the miniaturization and functionalization of an ion source for (portable) mass spectrometry (MS). Two versions of a 3D-printed cartridge for paper spray ionization (PSI) are demonstrated, assessed, and compared. We first focus on the use of

  6. Rapid monitoring particulate radiocesium with nonwoven fabric cartridge filter and application to field monitoring

    International Nuclear Information System (INIS)

    Tsuji, Hideki; Yasutaka, Tetsuo; Kondo, Yoshihiko; Kawashima, Shoji

    2013-01-01

    A method for rapid monitoring particulate radiocesium using a nonwoven fabric cartridge filter was developed, which needs no further preprocessing before served to a detector. By a performance test, more than 98% of suspended solid (SS) was collected. This method showed the same radioactivity measurement accuracy as filtration by membrane filter and more rapid extraction capability of SS. (author)

  7. Application of the quantitative autoradiography for determination of specific activity of labelled non-metallic inclusions

    International Nuclear Information System (INIS)

    Kowalczyk, J.T.; Wilczynski, A.W.

    1983-01-01

    The knowledge of specific activity of labelled non-metallic inclusions, i.e. the knowledge of the content of the radiotracer in a single inclusion, allows to obtain new information about the mechanism and the kinetics of steel deoxidation. In order to determine this specific activity quantitative autoradiography was used. Fo; this purpose, various standards of aluminium oxides with different amounts of cerium oxide Ce 2 O 3 and an aluminium-cerium alloy were prepared. The standards and the alloy were activated with thermal neutrons. Then several autoradiographs were made for these standards (ORWO AF-3 films were used). The autoradiographs served as the basis for evaluation of the standardization curves: optical density versus dimension of particles for a constant cerium concentration; optical density versus concentration of cerium for a constant dimension of particle. The samples of liquid steel were deoxidated with Al-Ce alloy. After labelled non-metallic inclusions had been isolated, the autoradiographs were made under the same conditions as for the standards. The standardization curves were used to determine the cerium content in the single inclusions. (author)

  8. [An optical-fiber-sensor-based spectrophotometer for soil non-metallic nutrient determination].

    Science.gov (United States)

    He, Dong-xian; Hu, Juan-xiu; Lu, Shao-kun; He, Hou-yong

    2012-01-01

    In order to achieve rapid, convenient and efficient soil nutrient determination in soil testing and fertilizer recommendation, a portable optical-fiber-sensor-based spectrophotometer including immersed fiber sensor, flat field holographic concave grating, and diode array detector was developed for soil non-metallic nutrient determination. According to national standard of ultraviolet and visible spectrophotometer with JJG 178-2007, the wavelength accuracy and repeatability, baseline stability, transmittance accuracy and repeatability measured by the prototype instrument were satisfied with the national standard of III level; minimum spectral bandwidth, noise and excursion, and stray light were satisfied with the national standard of IV level. Significant linear relationships with slope of closing to 1 were found between the soil available nutrient contents including soil nitrate nitrogen, ammonia nitrogen, available phosphorus, available sulfur, available boron, and organic matter measured by the prototype instrument compared with that measured by two commercial single-beam-based and dual-beam-based spectrophotometers. No significant differences were revealed from the above comparison data. Therefore, the optical-fiber-sensor-based spectrophotometer can be used for rapid soil non-metallic nutrient determination with a high accuracy.

  9. Influence of refining time on nonmetallic inclusions in a low-carbon, silicon-killed steel

    International Nuclear Information System (INIS)

    Fernandes, Marcolino; Pires, Jose Carlos; Cheung, Noe; Garcia, Amauri

    2003-01-01

    Nonmetallic inclusions are harmful to the mechanical properties of every kind of steel produced worldwide. The greater the size of the inclusion present in the structure of a determined kind of steel, the greater its negative effect on the quality of the steel. Therefore, the objective of this work was to investigate the size, the quantity, the shape and the chemical composition of nonmetallic inclusions formed throughout the refining process of silicon-killed, low-carbon steel, as a function of the treatment time in a ladle furnace, trying to ensure the flotation of inclusions bigger than 25 μm. This investigation was carried out using a scanning electron microscope (SEM), with an analysis system using energy dispersive spectometry (EDS). Based on this work, it was possible to know more precisely the nature of the inclusions, the necessary time to ensure flotation of large inclusions, the efficiency of the slag to capture the inclusions, and the inclusion level of the steel throughout its refining process to try to obtain a higher quality steel product

  10. Bacterial assimilation reduction of iron in the treatment of non-metallics

    Directory of Open Access Journals (Sweden)

    Peter Malachovský

    2005-11-01

    Full Text Available Natural non-metallics, including granitoide and quartz sands, often contain iron which decreases the whiteness of these raw materials. Insoluble Fe3+ in these samples could be reduced to soluble Fe2+ by bacteria of Bacillus spp. and Saccharomyces spp. The leaching effect, observed by the measurement of Fe2+concentration in a solution, showed higher activities of a bacterial kind isolated from the Bajkal lake and also by using of yeast Saccharomyces sp. during bioleaching of quartz sands. However, allkinds of Bacillus spp. isolated from the Slovak deposit and from Bajkal lake were very active in the iron reduction during bioleaching of the feldspar raw material. This metal was efficiently removed from quartz sands as documented by the Fe2O3 decrease (from 0,317 % to 0,126 % and from feldpars raw materials by the Fe2O3 decrease (from 0,288 % to 0,115 % after bioleaching. The whiteness of these non-metallics was increased during a visual comparison of samples before and after bioleaching but samples contain selected magnetic particles. A removal of iron as well as a release of iron minerals from silicate matrix should increase the effect of the magnetic separation and should give a product which is suitable for industrial applications.

  11. Standard practice for extreme value analysis of nonmetallic inclusions in steel and other microstructural features

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This practice describes a methodology to statistically characterize the distribution of the largest indigenous nonmetallic inclusions in steel specimens based upon quantitative metallographic measurements. The practice is not suitable for assessing exogenous inclusions. 1.2 Based upon the statistical analysis, the nonmetallic content of different lots of steels can be compared. 1.3 This practice deals only with the recommended test methods and nothing in it should be construed as defining or establishing limits of acceptability. 1.4 The measured values are stated in SI units. For measurements obtained from light microscopy, linear feature parameters shall be reported as micrometers, and feature areas shall be reported as micrometers. 1.5 The methodology can be extended to other materials and to other microstructural features. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish app...

  12. Hydrothermal modification and recycling of nonmetallic particles from waste print circuit boards.

    Science.gov (United States)

    Gao, Xuehua; Li, Qisheng; Qiu, Jun

    2018-04-01

    Nonmetallic particles recycled from waste print circuit boards (NPRPs) were modified by a hydrothermal treatment method and the catalysts, solvents, temperature and time were investigated, which affected the modification effect of NPRPs. The mild hydrothermal treatment method does not need high temperature, and would not cause secondary pollution. Further, the modified NPRPs were used as the raw materials for the epoxy resin and glass fibers/epoxy resin composites, which were prepared by pouring and hot-pressing method. The mechanical properties and morphology of the composites were discussed. The results showed that relative intensity of the hydroxyl bonds on the surface of NPRPs increased 58.9% after modification. The mechanical tests revealed that both flexural and impact properties of the composites can be significantly improved by adding the modified NPRPs. Particularly, the maximum increment of flexural strength, flexural modulus and impact strength of the epoxy matrix composites with 30% modified NPRPs is 40.1%, 80.0% and 79.0%, respectively. Hydrothermal treatment can modify surface of NPRPs successfully and modified NPRPs can not only improve the properties of the composites, but also reduce the production cost of the composites and environmental pollution. Thus, we develop a new way to recycle nonmetallic materials of waste print circuit boards and the highest level of waste material recycling with the raw materials-products-raw materials closed cycle can be realized through the hydrothermal modification and reuse of NPRPs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. A Fully Non-Metallic Gas Turbine Engine Enabled by Additive Manufacturing

    Science.gov (United States)

    Grady, Joseph E.; Halbig, Michael C.; Singh, Mrityunjay

    2015-01-01

    In a NASA Aeronautics Research Institute (NARI) sponsored program entitled "A Fully Non-Metallic Gas Turbine Engine Enabled by Additive Manufacturing", evaluation of emerging materials and additive manufacturing technologies was carried out. These technologies may enable fully non-metallic gas turbine engines in the future. This paper highlights the results of engine system trade studies which were carried out to estimate reduction in engine emissions and fuel burn enabled due to advanced materials and manufacturing processes. A number of key engine components were identified in which advanced materials and additive manufacturing processes would provide the most significant benefits to engine operation. In addition, feasibility of using additive manufacturing technologies to fabricate gas turbine engine components from polymer and ceramic matrix composite were demonstrated. A wide variety of prototype components (inlet guide vanes (IGV), acoustic liners, engine access door) were additively manufactured using high temperature polymer materials. Ceramic matrix composite components included first stage nozzle segments and high pressure turbine nozzle segments for a cooled doublet vane. In addition, IGVs and acoustic liners were tested in simulated engine conditions in test rigs. The test results are reported and discussed in detail.

  14. Automated Classification and Analysis of Non-metallic Inclusion Data Sets

    Science.gov (United States)

    Abdulsalam, Mohammad; Zhang, Tongsheng; Tan, Jia; Webler, Bryan A.

    2018-05-01

    The aim of this study is to utilize principal component analysis (PCA), clustering methods, and correlation analysis to condense and examine large, multivariate data sets produced from automated analysis of non-metallic inclusions. Non-metallic inclusions play a major role in defining the properties of steel and their examination has been greatly aided by automated analysis in scanning electron microscopes equipped with energy dispersive X-ray spectroscopy. The methods were applied to analyze inclusions on two sets of samples: two laboratory-scale samples and four industrial samples from a near-finished 4140 alloy steel components with varying machinability. The laboratory samples had well-defined inclusions chemistries, composed of MgO-Al2O3-CaO, spinel (MgO-Al2O3), and calcium aluminate inclusions. The industrial samples contained MnS inclusions as well as (Ca,Mn)S + calcium aluminate oxide inclusions. PCA could be used to reduce inclusion chemistry variables to a 2D plot, which revealed inclusion chemistry groupings in the samples. Clustering methods were used to automatically classify inclusion chemistry measurements into groups, i.e., no user-defined rules were required.

  15. Evaluation of Accelerated Ageing Tests for Metallic and Non-Metallic Graffiti Paints Applied to Stone

    Directory of Open Access Journals (Sweden)

    Patricia Sanmartín

    2017-10-01

    Full Text Available Graffiti are increasingly observed on urban and peri-urban buildings and their removal requires a huge financial outlay by local governments and agencies. Graffiti are not usually removed immediately, but rather over the passage of time, viz. months or even years. In this study, which forms part of a wider research project on graffiti removal, different methods (gravimetric analysis, examination of digital images, colour and infrared measurements were used to evaluate the performance of accelerated ageing tests (involving exposure to humidity, freeze-thawing cycles and NaCl and Na2SO4 salts for graffiti painted on stone. Silver (metallic and black (non-metallic graffiti spray paints were applied to two types of igneous rock (granite and rhyolitic ignimbrite and one sedimentary rock (fossiliferous limestone, i.e., biocalcarenite. The metallic and non-metallic graffiti spray paints acted differently on the stone surfaces, both chemically and physically. Older graffiti were found to be more vulnerable to weathering agents. The ageing test with NaCl and particularly Na2SO4, both applied to granite, proved the most severe on the paints, yielding more detrimental and faster artificial ageing of the type of material under study.

  16. Simplified quality control of radioactive seeds in sterile cartridge for prostate brachytherapy using an imaging plate and a collimator

    International Nuclear Information System (INIS)

    Saze, T.; Miyoshi, H.; Maezawa, H.; Kubota, M.; Furutani, S.; Nishitani, H.; Kawaguchi, Y.; Nakayama, S.; Ito, S.; Nishizawa, K.

    2008-01-01

    Image analyzer system and collimator has been successfully applied to calibrate simultaneously multiple 125 I seeds in a sterile cartridge. Seeds within the cartridge were placed on an imaging plate, and the imaging plate irradiated. To remove scatter radiation, and improve spatial resolution of seed images, this study used a specially designed collimator. The irradiated imaging plate was scanned using an image analyzer system, and radioactivity intensities of seed images were given in counts. Counts could be translated to profiles, and each seed within the cartridge was analyzed. It is observed that a good correlation between counts and total radioactivity of the seeds within the cartridge. Thus, using a least-squares line, it was possible to calibrate a seed with unknown apparent activity. By analyzing the profiles, it was possible not only to detect a mis calibrated seed in the cartridge from its relative difference in counts, but also to identify its position in the cartridge. Using an imaging analyzer system, all seeds in a cartridge could be calibrated in a sterile environment. (author)

  17. A mathematical model and an approximate method for calculating the fracture characteristics of nonmetallic materials during laser cutting

    Energy Technology Data Exchange (ETDEWEB)

    Smorodin, F.K.; Druzhinin, G.V.

    1991-01-01

    A mathematical model is proposed which describes the fracture behavior of amorphous materials during laser cutting. The model, which is based on boundary layer equations, is reduced to ordinary differential equations with the corresponding boundary conditions. The reduced model is used to develop an approximate method for calculating the fracture characteristics of nonmetallic materials.

  18. Electromagnetic detection and infrared visualization techniques for non-metallic inclusions in molten aluminum

    International Nuclear Information System (INIS)

    Fei Ming; Ludwig, Reinhold; Shankar, Sumanth; Apelian, Diran

    2002-01-01

    The role of detecting non-metallic and weakly conducting inclusions in hot melts during the manufacturing process is of major importance. However, the key impediment to assessing melt cleanliness is the quantification of the level of inclusions. In this paper, we present the theory and practice in using a magnetic force-based detection system capable of monitoring small inclusions of micron-size dimensions. The idea is to force the non-conducting inclusions to a detection location (the free melt surface) by electromagnetic Archimedes forces. Further, an infrared (IR) imaging system can then be applied to detect their thermal signature. Finally, a novel image-processing algorithm is used to analyze the inclusion level on the measurement surface

  19. Stepped-Frequency Ground-Penetrating Radar for Detection of Small Non-metallic Buried Objects

    DEFF Research Database (Denmark)

    Jakobsen, Kaj Bjarne; Sørensen, Helge Bjarup Dissing; Nymann, Ole

    1997-01-01

    -shaped objects. Two-dimensional probe-correction and addition signal processing are applied to the raw probe-data. The probe used in this experiment was an open-ended waveguide operating at S-band. The movements of the probe are controlled by two stepmotors via an RS-232 interface. The probe is connected...... at each measurement point using a mesh-grid with a resolution down to 1 mm by 1 mm. The size of the scan area is 1410 mm by 210 mm. Measurements have been performed on loamy soil containing a buried M-56, a non-metallic AP-mine, and various other mine-like objects made of solid plastic, brass, aluminum...

  20. Heterogeneous electrochemical CO2 reduction using nonmetallic carbon-based catalysts: current status and future challenges

    Science.gov (United States)

    Ma, Tao; Fan, Qun; Tao, Hengcong; Han, Zishan; Jia, Mingwen; Gao, Yunnan; Ma, Wangjing; Sun, Zhenyu

    2017-11-01

    Electrochemical CO2 reduction (ECR) offers an important pathway for renewable energy storage and fuels production. It still remains a challenge in designing highly selective, energy-efficient, robust, and cost-effective electrocatalysts to facilitate this kinetically slow process. Metal-free carbon-based materials have features of low cost, good electrical conductivity, renewability, diverse structure, and tunability in surface chemistry. In particular, surface functionalization of carbon materials, for example by doping with heteroatoms, enables access to unique active site architectures for CO2 adsorption and activation, leading to interesting catalytic performances in ECR. We aim to provide a comprehensive review of this category of metal-free catalysts for ECR, providing discussions and/or comparisons among different nonmetallic catalysts, and also possible origin of catalytic activity. Fundamentals and some future challenges are also described.

  1. Capacitance probe for detection of anomalies in non-metallic plastic pipe

    Science.gov (United States)

    Mathur, Mahendra P.; Spenik, James L.; Condon, Christopher M.; Anderson, Rodney; Driscoll, Daniel J.; Fincham, Jr., William L.; Monazam, Esmail R.

    2010-11-23

    The disclosure relates to analysis of materials using a capacitive sensor to detect anomalies through comparison of measured capacitances. The capacitive sensor is used in conjunction with a capacitance measurement device, a location device, and a processor in order to generate a capacitance versus location output which may be inspected for the detection and localization of anomalies within the material under test. The components may be carried as payload on an inspection vehicle which may traverse through a pipe interior, allowing evaluation of nonmetallic or plastic pipes when the piping exterior is not accessible. In an embodiment, supporting components are solid-state devices powered by a low voltage on-board power supply, providing for use in environments where voltage levels may be restricted.

  2. Calculating the Carrying Capacity of Flexural Prestressed Concrete Beams with Non-Metallic Reinforcement

    Directory of Open Access Journals (Sweden)

    Mantas Atutis

    2011-04-01

    Full Text Available The article reviews moment resistance design methods of prestressed concrete beams with fibre-reinforced polymer (FRP reinforcement. FRP tendons exhibit linear elastic response to rupture without yielding and thus failure is expected to be brittle. The structural behaviour of beams prestressed with FRP tendons is different from beams with traditional steel reinforcement. Depending on the reinforcement ratio, the flexural behaviour of the beam can be divided into several groups. The numerical results show that depending on the nature of the element failure, moment resistance calculation results are different by using reviewed methods. It was found, that the use of non-metallic reinforcement in prestressed concrete structures is effective: moment capacity is about 5% higher than that of the beams with conventional steel reinforcement.Article in Lithuanian

  3. Standard Test Method for Testing Nonmetallic Seal Materials by Immersion in a Simulated Geothermal Test Fluid

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers a procedure for a laboratory test for performing an initial evaluation (screening) of nonmetallic seal materials by immersion in a simulated geothermal test fluid. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6 and 11.7.

  4. Industrial application of liquid steel filtration out of dispersed nonmetallic phase in the continuous casting machine

    Directory of Open Access Journals (Sweden)

    K. Janiszewski

    2013-01-01

    Full Text Available Hitherto existing investigations concerning the ceramic filter use in the steel making processes (both of laboratory and industrial scale have given good results. The obtained results of filtration (in the laboratory have proved that this method may be used as an effective and cheap way of steel filtration from non-metallic inclusions. Placing filters in the tundish is the best location in consideration of limiting the possibility of secondary pollution of steel. Yet, the results presented in this paper, of an experiment prepared and carried out in the industrial environment, are the only positive results obtained, which are connected with so much quantities of liquid steel processed with use of the multi-hole ceramic filters.

  5. Morphology and Orientation Selection of Non-metallic Inclusions in Electrified Molten Metal

    Science.gov (United States)

    Zhao, Z. C.; Qin, R. S.

    2017-10-01

    The effect of electric current on morphology and orientation selection of non-metallic inclusions in molten metal has been investigated using theoretical modeling and numerical calculation. Two geometric factors, namely the circularity ( fc ) and alignment ratio ( fe ) were introduced to describe the inclusions shape and configuration. Electric current free energy was calculated and the values were used to determine the thermodynamic preference between different microstructures. Electric current promotes the development of inclusion along the current direction by either expatiating directional growth or enhancing directional agglomeration. Reconfiguration of the inclusions to reduce the system electric resistance drives the phenomena. The morphology and orientation selection follow the routine to reduce electric free energy. The numerical results are in agreement with our experimental observations.

  6. A Method for Promoting Assembly of Metallic and Nonmetallic Nanoparticles into Interfacial Monolayer Films.

    Science.gov (United States)

    Xu, Yikai; Konrad, Magdalena P; Lee, Wendy W Y; Ye, Ziwei; Bell, Steven E J

    2016-08-10

    Two-dimensional metal nanoparticle arrays are normally constructed at liquid-oil interfaces by modifying the surfaces of the constituent nanoparticles so that they self-assemble. Here we present a general and facile new approach for promoting such interfacial assembly without any surface modification. The method use salts that have hydrophobic ions of opposite charge to the nanoparticles, which sit in the oil layer and thus reduce the Coulombic repulsion between the particles in the organic phase, allowing the particles to sit in close proximity to each other at the interface. The advantage of this method is that because it does not require the surface of the particles to be modified it allows nonmetallic particles including TiO2 and SiO2 to be assembled into dense interfacial layers using the same procedure as is used for metallic particles. This opens up a route to a new family of nanostructured functional materials.

  7. The sixth plenary meeting of the seminar 'Steel and nonmetallic inclusions'

    International Nuclear Information System (INIS)

    Kiseleva, S.A.

    1976-01-01

    The sixth plenary session of the 'Steel and non-metallic inclusions' seminar held in Volgograd in July of 1976 dealt, primarily with the application of rare-earth REM and alkaline earth AEM metals in metallurgy. The following problems were discussed: REM sources, alloyages with REM and AEM rational methods of producing them, industrial application of REM in metallurgy, the effect of REM on the quality of steel and the physicochemical nature of at effect. The seminar ended with a summary of the discussion and recommendations as to the areas of application of REM in metallurgy, as well as a summary of the basic requirements to be met in employing those metals in any field of metallurgy

  8. Analysis and simulation of non-metallic inclusions in spheroidal graphite iron

    International Nuclear Information System (INIS)

    Pustal, B; Schelnberger, B; Bührig-Polaczek, A

    2016-01-01

    Non-metallic inclusions in spheroidal cast iron (SGI) reduce fatigue strength and yield strength. This type of inclusion usually accumulates at grain boundaries. Papers addressing this topic show the overall impact of both the fraction of so-called white (carbides) and black (non-metallic) inclusions on mechanical properties. In the present work we focus on the origin and the formation conditions of black Mg-bearing inclusions, further distinguishing between Si-bearing and non-Si-bearing Mg inclusions. The formation was simulated applying thermodynamic approaches. Moreover, appropriate experiments have been carried out and a large number of particles have been studied applying innovative feature analysis with regard to shape, size, and composition. Magnesium silicates are predicted at elevated oxygen concentrations, whereas at low levels of oxygen sulphides and carbides appear at a late stage of solidification. Experiments with three consecutive flow obstacles show that the amount of magnesium silicates decrease after each of the three obstacles, whereas the fraction of non-Si-bearing inclusions remains approximately constant. The size of inclusions divides in halves over the flow path and the number of particles increases accordingly. We point out that based on feature analysis Mg-O-C bearing inclusion show disadvantageous form factors for which reason this kind of inclusions may be extremely harmful in terms of crack initiation. All results obtained indicate that magnesium silicates are entrapped on mould filling, whereas Mg-(O, C, S, P, N) bearing particles are precipitates at late stages of solidification. Consequently, the only avoidance strategy is setting up optimum retained magnesium content. (paper)

  9. Do insulin cartridges really provide a lower risk of potential diabetes complications than traditional vials?

    Science.gov (United States)

    Al-Sharayri, Mohammad G; Aljbori, Tariq M; Migdadi, Qusai M; Al-Omoush, Marwa B; Jaarah, Ayman R

    2014-09-01

    Recently, many publicly funded healthcare organizations suffered from an economical crisis. This forced some organizations to utilize less costly alternatives where possible. Insulin cartridges and vials are examples. Many patients are questioning the difference between the two alternatives as they contain the same active ingredient. To find out if insulin cartridges really provide a lower risk of potential diabetes complications than traditional vials. A questionnaire was used to ask two random samples of diabetic patients about the development of some diabetes complications. The first sample (n = 41) consisted of patients using cartridges; the second sample (n = 40) consisted of patients using vials. Patients were randomly selected from the endocrine clinic and the out-patient pharmacy in Al-Hussein Hospital in King Hussein Medical Center in Amman- Jordan. 44% of respondents in the first sample did not suffer from any complication; on the other hand, the percentage was only 15% of respondents in the second sample. All respondents (100%) in the first sample suffered from only 2 complications or less; however, 25% of the respondents in the second sample suffered from 3 or more complications. Nephropathy complications, were slightly higher in the first sample; 22% compared to 15% in the second sample. On the other hand, all complications reported in the second sample were higher; 30% for neuropathy, 65% for retinopathy complications and 42.5% for extremities damage compared to only 9.7%, 7.3% and 26.8% respectively in the first sample. In general, respondents who were using cartridges reported a lesser incidence of diabetes complications. Although many organizations suffered from an economical crisis, the cost-effectiveness aspect should be taken into consideration when purchasing medical alternatives. This will provide higher quality of life for patients and eventually lower hidden and future costs for the organizations.

  10. Safety limits of half-mask cartridge respirators for organic solvent vapors

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Recent studies of the effective service life (safety limits) for typical half-mask cartridge respirators have shown these devices to be unsuitable for certain organic vapors, e.g., methanol, methylamine, vinyl chloride, and dichloromethane, because the effective service life is too short. For these vapors other forms of protection such as air-supplied respirators are recommended. The experimentally determined service life for many vapors is shorter--sometimes significantly shorter--than predicted by adsorption theory

  11. Characterization of cartridge filters from the IEA-R1 Nuclear Reactor

    International Nuclear Information System (INIS)

    2015-01-01

    The management of radioactive waste ensures safety to human health and the environment nowadays and for the future, without overwhelming the upcoming generations. The primary characterization of radioactive waste is one of the main steps in the management of radioactive waste. This step permits to choose the best treatment for the radioactive waste before forwarding it to its final disposal. The aim of the present work is the primary characterization of cartridge filters from the IEA-R1 nuclear reactor utilizing gamma-ray spectrometry, and the method of Monte Carlo for calibration. The IEA-R1 is located in the Nuclear and Energy Research Institute (IPEN - CNEN) in the city of Sao Paulo, Brazil. Cartridge filters are used for purification of the cooling water that is pumped through the core of the pool type nuclear research reactors. Once worn out, these filters are replaced and then become radioactive waste. Determination of the radioactive inventory is of paramount importance in the management of such radioactive waste, and one of the main methods for doing so is the gamma-ray spectrometry, which can identify and quantify high energy photon emitters. The technique chosen for the characterization of radioactive waste in the present work is the gamma-ray spectrometry with High purity Germanium (HPGe) detectors. From the energy identified in the experimental spectrum, three radioisotopes were identified in the cartridge filter: 108m Ag, 110m Ag, 60 Co. For the estimated activity of the filter, the calibration in efficiency was made utilizing the MCNP4C code of the Monte Carlo method. Such method was chosen because there is no standard source available in the same geometry of the cartridge filter, therefore a simulation had to be developed in order to reach a calibration equation, necessary to estimate the activity of the radioactive waste. The results presented an activity value in the order of MBq for all radioisotopes. (authors)

  12. Characterization of cartridge filters from the IEA-R1 Nuclear Reactor

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-07-01

    The management of radioactive waste ensures safety to human health and the environment nowadays and for the future, without overwhelming the upcoming generations. The primary characterization of radioactive waste is one of the main steps in the management of radioactive waste. This step permits to choose the best treatment for the radioactive waste before forwarding it to its final disposal. The aim of the present work is the primary characterization of cartridge filters from the IEA-R1 nuclear reactor utilizing gamma-ray spectrometry, and the method of Monte Carlo for calibration. The IEA-R1 is located in the Nuclear and Energy Research Institute (IPEN - CNEN) in the city of Sao Paulo, Brazil. Cartridge filters are used for purification of the cooling water that is pumped through the core of the pool type nuclear research reactors. Once worn out, these filters are replaced and then become radioactive waste. Determination of the radioactive inventory is of paramount importance in the management of such radioactive waste, and one of the main methods for doing so is the gamma-ray spectrometry, which can identify and quantify high energy photon emitters. The technique chosen for the characterization of radioactive waste in the present work is the gamma-ray spectrometry with High purity Germanium (HPGe) detectors. From the energy identified in the experimental spectrum, three radioisotopes were identified in the cartridge filter: {sup 108m}Ag, {sup 110m}Ag, {sup 60}Co. For the estimated activity of the filter, the calibration in efficiency was made utilizing the MCNP4C code of the Monte Carlo method. Such method was chosen because there is no standard source available in the same geometry of the cartridge filter, therefore a simulation had to be developed in order to reach a calibration equation, necessary to estimate the activity of the radioactive waste. The results presented an activity value in the order of MBq for all radioisotopes. (authors)

  13. RPA using a multiplexed cartridge for low cost point of care diagnostics in the field.

    Science.gov (United States)

    Ereku, Luck Tosan; Mackay, Ruth E; Craw, Pascal; Naveenathayalan, Angel; Stead, Thomas; Branavan, Manorharanehru; Balachandran, Wamadeva

    2018-04-15

    A point of care device utilising Lab-on-a-Chip technologies that is applicable for biological pathogens was designed, fabricated and tested showing sample in to answer out capabilities. The purpose of the design was to develop a cartridge with the capability to perform nucleic acid extraction and purification from a sample using a chitosan membrane at an acidic pH. Waste was stored within the cartridge with the use of sodium polyacrylate to solidify or gelate the sample in a single chamber. Nucleic acid elution was conducted using the RPA amplification reagents (alkaline pH). Passive valves were used to regulate the fluid flow and a multiplexer was designed to distribute the fluid into six microchambers for amplification reactions. Cartridges were produced using soft lithography of silicone from 3D printed moulds, bonded to glass substrates. The isothermal technique, RPA is employed for amplification. This paper shows the results from two separate experiments: the first using the RPA control nucleic acid, the second showing successful amplification from Chlamydia Trachomatis. Endpoint analysis conducted for the RPA analysis was gel electrophoresis that showed 143 base pair DNA was amplified successfully for positive samples whilst negative samples did not show amplification. End point analysis for Chlamydia Trachomatis samples was fluorescence detection that showed successful detection of 1 copy/μL and 10 copies/μL spiked in a MES buffer. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  14. Behavioral response and pain perception to computer controlled local anesthetic delivery system and cartridge syringe

    Directory of Open Access Journals (Sweden)

    T D Yogesh Kumar

    2015-01-01

    Full Text Available Aim: The present study evaluated and compared the pain perception, behavioral response, physiological parameters, and the role of topical anesthetic administration during local anesthetic administration with cartridge syringe and computer controlled local anesthetic delivery system (CCLAD. Design: A randomized controlled crossover study was carried out with 120 children aged 7-11 years. They were randomly divided into Group A: Receiving injection with CCLAD during first visit; Group B: Receiving injection with cartridge syringe during first visit. They were further subdivided into three subgroups based on the topical application used: (a 20% benzocaine; (b pressure with cotton applicator; (c no topical application. Pulse rate and blood pressure were recorded before and during injection procedure. Objective evaluation of disruptive behavior and subjective evaluation of pain were done using face legs activity cry consolability scale and modified facial image scale, respectively. The washout period between the two visits was 1-week. Results: Injections with CCLAD produced significantly lesser pain response, disruptive behavior (P < 0.001, and pulse rate (P < 0.05 when compared to cartridge syringe injections. Application of benzocaine produced lesser pain response and disruptive behavior when compared to the other two subgroups, although the result was not significant. Conclusion: Usage of techniques which enhance behavioral response in children like injections with CCLAD can be considered as a possible step toward achieving a pain-free pediatric dental practice.

  15. Change in muzzle velocity due to freezing and water immersion of .22, long rifle, K.F. cartridges.

    Science.gov (United States)

    Jauhari, M; Chatterjee, S M; Ghosh, P K

    1975-01-01

    A study of change in muzzle velocity due to freezing and water immersion of .22, long rifle, K. F. cartridges has been presented. A statistical criterion has been formulated to ascertain whether or not a cartridge undergoes a change in muzzle velocity due to a particular treatment. The muzzle velocity data of .22, long rifle, K. F. cartridges, obtained by an electronic timer before and after the various treatments, have been analyzed in the light of this criterion. These cartridges have generally been found to suffer considerable loss in muzzle velocity when immersed in water for three weeks and also when immersed in water for three days and simultaneously cooled to 0 degrees C. The forensic significance of this loss in muzzle velocity has been discussed.

  16. An aviation security (AVSEC) screening demonstrator for the detection of non-metallic threats at 28-33 GHz

    Science.gov (United States)

    Salmon, Neil A.; Bowring, Nick; Hutchinson, Simon; Southgate, Matthew; O'Reilly, Dean

    2013-10-01

    The unique selling proposition of millimetre wave technology for security screening is that it provides a stand-off or portal scenario sensing capability for non-metallic threats. The capabilities to detect some non-metallic threats are investigated in this paper, whilst recommissioning the AVSEC portal screening system at the Manchester Metropolitan University. The AVSEC system is a large aperture (1.6 m) portal screening imager which uses spatially incoherent illumination at 28-33 GHz from mode scrambling cavities to illuminate the subject. The imaging capability is critically analysed in terms of this illumination. A novel technique for the measurement of reflectance, refractive index and extinction coefficient is investigated and this then use to characterise the signatures of nitromethane, hexane, methanol, bees wax and baking flour. Millimetre wave images are shown how these liquids in polycarbonate bottles and the other materials appear against the human body.

  17. Accurate determination of non-metallic impurities in high purity tetramethylammonium hydroxide using inductively coupled plasma tandem mass spectrometry

    Science.gov (United States)

    Fu, Liang; Xie, Hualin; Shi, Shuyun; Chen, Xiaoqing

    2018-06-01

    The content of non-metallic impurities in high-purity tetramethylammonium hydroxide (HPTMAH) aqueous solution has an important influence on the yield, electrical properties and reliability of the integrated circuit during the process of chip etching and cleaning. Therefore, an efficient analytical method to directly quantify the content of non-metallic impurities in HPTMAH aqueous solutions is necessary. The present study was aimed to develop a novel method that can accurately determine seven non-metallic impurities (B, Si, P, S, Cl, As, and Se) in an aqueous solution of HPTMAH by inductively coupled plasma tandem mass spectrometry (ICP-MS/MS). The samples were measured using a direct injection method. In the MS/MS mode, oxygen and hydrogen were used as reaction gases in the octopole reaction system (ORS) to eliminate mass spectral interferences during the analytical process. The detection limits of B, Si, P, S, Cl, As, and Se were 0.31, 0.48, 0.051, 0.27, 3.10, 0.008, and 0.005 μg L-1, respectively. The samples were analyzed by the developed method and the sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) was used for contrastive analysis. The values of these seven elements measured using ICP-MS/MS were consistent with those measured by SF-ICP-MS. The proposed method can be utilized to analyze non-metallic impurities in HPTMAH aqueous solution. Table S2 Multiple potential interferences on the analytes. Table S3 Parameters of calibration curve and the detection limit (DL). Table S4 Results obtained for 25% concentration high-purity grade TMAH aqueous solution samples (μg L-1, mean ± standard deviation, n = 10).

  18. Toward environmentally-benign utilization of nonmetallic fraction of waste printed circuit boards as modifier and precursor

    Energy Technology Data Exchange (ETDEWEB)

    Hadi, Pejman; Ning, Chao; Ouyang, Weiyi; Xu, Meng [Chemical and Biomolecular Engineering Department, Hong Kong University of Science and Technology, Clear Water Bay Road, Hong Kong Special Administrative Region (Hong Kong); Lin, Carol S.K. [School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong Special Administrative Region (Hong Kong); McKay, Gordon, E-mail: kemckayg@ust.hk [Chemical and Biomolecular Engineering Department, Hong Kong University of Science and Technology, Clear Water Bay Road, Hong Kong Special Administrative Region (Hong Kong); Division of Sustainable Development, College of Science, Engineering and Technology, Hamad bin Khalifa University, Doha (Qatar)

    2015-01-15

    Highlights: • Environmental impacts of electronic waste and specifically waste printed circuit boards. • Review of the recycling techniques of waste printed circuit boards. • Advantages of physico-mechanical recycling techniques over chemical methods. • Utilization of nonmetallic fraction of waste printed circuit boards as modifier/filler. • Recent advances in the use of nonmetallic fraction of waste printed circuit boards as precursor. - Abstract: Electronic waste, including printed circuit boards, is growing at an alarming rate due to the accelerated technological progress and the shorter lifespan of the electronic equipment. In the past decades, due to the lack of proper economic and environmentally-benign recycling technologies, a major fraction of e-waste generated was either destined to landfills or incinerated with the sole intention of its disposal disregarding the toxic nature of this waste. Recently, with the increasing public awareness over their environment and health issues and with the enaction of more stringent regulations, environmentally-benign recycling has been driven to be an alternative option partially replacing the traditional eco-unfriendly disposal methods. One of the most favorable green technologies has been the mechanical separation of the metallic and nonmetallic fraction of the waste printed circuit boards. Although metallic fraction, as the most profitable component, is used to generate the revenue of the separation process, the nonmetallic fraction (NMF) has been left isolated. Herein, the recent developments in the application of NMF have been comprehensively reviewed and an eco-friendly emerging usage of NMF as a value-added material for sustainable remediation has been introduced.

  19. Toward environmentally-benign utilization of nonmetallic fraction of waste printed circuit boards as modifier and precursor

    International Nuclear Information System (INIS)

    Hadi, Pejman; Ning, Chao; Ouyang, Weiyi; Xu, Meng; Lin, Carol S.K.; McKay, Gordon

    2015-01-01

    Highlights: • Environmental impacts of electronic waste and specifically waste printed circuit boards. • Review of the recycling techniques of waste printed circuit boards. • Advantages of physico-mechanical recycling techniques over chemical methods. • Utilization of nonmetallic fraction of waste printed circuit boards as modifier/filler. • Recent advances in the use of nonmetallic fraction of waste printed circuit boards as precursor. - Abstract: Electronic waste, including printed circuit boards, is growing at an alarming rate due to the accelerated technological progress and the shorter lifespan of the electronic equipment. In the past decades, due to the lack of proper economic and environmentally-benign recycling technologies, a major fraction of e-waste generated was either destined to landfills or incinerated with the sole intention of its disposal disregarding the toxic nature of this waste. Recently, with the increasing public awareness over their environment and health issues and with the enaction of more stringent regulations, environmentally-benign recycling has been driven to be an alternative option partially replacing the traditional eco-unfriendly disposal methods. One of the most favorable green technologies has been the mechanical separation of the metallic and nonmetallic fraction of the waste printed circuit boards. Although metallic fraction, as the most profitable component, is used to generate the revenue of the separation process, the nonmetallic fraction (NMF) has been left isolated. Herein, the recent developments in the application of NMF have been comprehensively reviewed and an eco-friendly emerging usage of NMF as a value-added material for sustainable remediation has been introduced

  20. Characterization of impact damage in metallic/nonmetallic composites using x-ray computed tomography imaging

    International Nuclear Information System (INIS)

    Green, William H.; Wells, Joseph M.

    1999-01-01

    Characterizing internal impact damage in composites can be difficult, especially in structurally complex composites or those consisting of many materials. Many methods for nondestructive inspection/nondestructive testing (NDI/NDT) of materials have been known and in use for many years, including x-ray film, real-time, and digital radiographic techniques, and ultrasonic techniques. However, these techniques are generally not capable of three-dimensional (3D) mapping of complex damage patterns, which is necessary to visualize and understand damage cracking modes. Conventional x-ray radiography suffers from the loss of 3D information. Structural complexity and signal dispersion in materials with many interfaces significantly effect ultrasonic inspection techniques. This makes inspection scan interpretation difficult, especially in composites containing a number of different materials (i.e., polymer, ceramic, and metallic). X-ray computed tomography (CT) is broadly applicable to any material or test object through which a beam of penetrating radiation may be passed and detected, including metals, plastics, ceramics, metallic/nonmetallic composites, and assemblies. The principal advantage of CT is that it provides densitometric (that is, radiological density and geometry) images of thin cross sections through an object. Because of the absence of structural superposition, images are much easier to interpret than conventional radiological images. The user can quickly learn to read CT data because images correspond more closely to the way the human mind visualizes 3D structures than projection radiology (that is, film radiography, real-time radiography (RTR), and digital radiography (DR)). Any number of CT images, or slices, from scanning an object can be volumetrically reconstructed to produce a 3D attenuation map of the object. The 3D attenuation data can be rendered using multiplanar or 3D solid visualization. In multiplanar visualization there are four planes of view

  1. Rapid, efficient and selective preconcentration of benzo[a]pyrene (BaP) by molecularly imprinted composite cartridge and HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Çorman, Mehmet Emin, E-mail: mecorman@sinop.edu.tr [Hacettepe University, Department of Chemistry, Ankara (Turkey); Sinop University, Department of Bioengineering, Sinop (Turkey); Armutcu, Canan [Hacettepe University, Department of Chemistry, Ankara (Turkey); Uzun, Lokman, E-mail: lokman@hacettepe.edu.tr [Hacettepe University, Department of Chemistry, Ankara (Turkey); Denizli, Adil [Hacettepe University, Department of Chemistry, Ankara (Turkey)

    2017-01-01

    In this study, cryogel-based molecularly imprinted composite cartridges were designed for the rapid, efficient, and selective preconcentration of benzo[a]pyrene (BaP) from water samples. First, a BaP-imprinted poly(2-hydroxyethyl methacrylate-N-methacryloyl-(L)-phenylalanine) composite cartridge was synthesized under semi-frozen conditions and characterized by scanning electron microscopy, elemental analysis, Fourier transform infrared spectroscopy, and swelling tests. After the optimization of preconcentration parameters, i.e., pH and initial BaP concentration, the selectivity and preconcentration efficiency, and reusability of these cartridges were also evaluated. In selectivity experiments, BaP imprinted composite cartridge exhibited binding capacities 3.09, 9.52, 8.87, and 8.77-fold higher than that of the non-imprinted composite cartridge in the presence of competitors, such as benzo[b]fluoranthene (BbF), benzo[k]fluoranthene (BkF), indeno[1,2,3-cd]pyrene (IcdP), and 1-naphthol, respectively. The method detection limit (MDL), relative standard deviation (RSD) and preconcentration efficiency (PE) of the synthesized composite cartridge were calculated as 24.86 μg/L, 1.60%, and 349.6%, respectively. - Highlights: • Cryogel based molecularly imprinted composite cartridges as solid-phase extraction sorbents • Combination unique structural features of cryogels with MIP • An excellent ability to recognize the BaP molecule even if single-run contact • Rapid, efficient, selective and cost-friendly PAH preconcentration • Hydrophobic interactions via N-methacryloyl-(L)-phenylalanine.

  2. The interaction between non-metallic inclusions and surface roughness in fatigue failure and their influence on fatigue strength

    International Nuclear Information System (INIS)

    Saberifar, S.; Mashreghi, A.R.; Mosalaeepur, M.; Ghasemi, S.S.

    2012-01-01

    Highlights: ► The fatigue strength of a tested steel was affected by inclusions and surface notches. ► Inclusions were the main fatigue crack sources even in rough specimens. ► The stress intensity factor represented the behavior of inclusions properly. ► In rough steels the effect of inclusions was intensified by surface roughness. ► The critical inclusion size increased when surface roughness was removed. -- Abstract: In this study, the influence of non-metallic inclusions on the fatigue behavior of 30MnVS6 steel containing different inclusion sizes and surface roughness has been investigated. Scanning electron microscope (SEM) was used to examine fatigue fracture origins. It was concluded that the non-metallic inclusions were dominant fatigue crack initiation sites in both smooth and rough specimens. This was justified by the calculation of stress intensity factor generated by both surface roughness and non-metallic inclusions, based on Murakami’s model. In addition, it was found that for a given stress, the critical inclusion size could be increased by eliminating the surface roughness.

  3. Determinants of Electricity Demand in Nonmetallic Mineral Products Industry: Evidence from a Comparative Study of Japan and China

    Directory of Open Access Journals (Sweden)

    Gang Du

    2015-06-01

    Full Text Available Electricity intensity is an important indicator for measuring production efficiency. A comparative study could offer a new perspective on investigating determinants of electricity demand. The Japanese non-metallic mineral products industry is chosen as the object for comparison considering its representative position in production efficiency. By adopting the cointegration model, this paper examines influencing factors of electricity demand in Japanese and Chinese non-metallic mineral products industries under the same framework. Results indicate that although economic growth and industrial development stages are different between the two countries, major factors that affect the sectoral energy consumption are the same. Specifically, economic growth and industrial activity contribute to the growth of sectoral electricity consumption, while R&D intensity, per capita productivity and electricity price are contributors to the decline of sectoral electricity consumption. Finally, in order to further investigate the development trend of sectoral electricity demand, future electricity consumption and conservation potential are predicted under different scenarios. Electricity demand of the Chinese non-metallic mineral products industry is predicted to be 680.53 TWh (terawatt-hours in 2020 and the sectoral electricity conservation potentials are estimated to be 118.26 TWh and 216.25 TWh under the moderate and advanced electricity-saving scenarios, respectively.

  4. Influence of non-metallic inclusions on fatigue strength of high manganese steel

    International Nuclear Information System (INIS)

    Maekawa, I.; Shibata, H.; Lee, J.H.; Nishida, Shin-ichi

    1991-01-01

    Six series of high manganese austenitic steel, which contain different inclusion quantity, were prepared. Fatigue experiments, tensile tests and Charpy tests were carried out. Influence of non-metallic inclusion and of temperature on the stress intensity threshold, fatigue crack propagation behavior, elastic-plastic fracture toughness and Charpy value were studied at room temperature and low temperature. In general, strength of this high manganese steel was reduced with increase of inclusion content. Influences of the direction of elongated inclusion with regard to the rolling direction on their strengths were also discussed based on SEM observation and numerical analysis for the stress concentration at a crack tip when an inclusion was near by the tip. According to these results, an inclusion acted as an obstacle to crack propagation for LT specimen. The roughness of fracture surface of ST specimen was larger than that of SL specimen, and the crack growth rate of the former was less than that of the latter. Fatigue life was increased with decrease of temperature, and mechanical parameters such as ΔK th and J 1c were decreased with increase of temperature. The Charpy value decreased clearly with decrease of temperature

  5. A first-principles study of light non-metallic atom substituted blue phosphorene

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Minglei [School of Mechanical Engineering, Southeast University, Nanjing 211189, Jiangsu (China); Tang, Wencheng, E-mail: 101000185@seu.edu.cn [School of Mechanical Engineering, Southeast University, Nanjing 211189, Jiangsu (China); Ren, Qingqiang [State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083, Hunan (China); Wang, Sa-ke [Department of Physics, Southeast University, Nanjing 210096, Jiangsu (China); Yu, Jin [School of Materials Science and Engineering, Southeast University, Nanjing 211189, Jiangsu (China); Jiangsu Key Laboratory of Advanced Metallic Materials, Southeast University, Nanjing 211189, Jiangsu (China); Du, Yanhui [School of Mechanical Engineering, Southeast University, Nanjing 211189, Jiangsu (China)

    2015-11-30

    Graphical abstract: - Highlights: • All the impurities are covalently bonded to blue phosphorene (with a single vacancy). • All the substituted systems are semiconductors. • B-substituted system exhibits direct bandgap semiconductor behavior. • The band gaps with spin polarization are found in C and O-substituted systems. • Our works can paves a new route at nanoscale for novel functionalities of optical and spintronics devices. - Abstract: First-principles calculations are implemented to study the geometric, electronic and magnetic properties of light non-metallic atom (B, C, N, O and F) substituted blue phosphorene. All the substituted systems are highly stable. The B-substituted system is a direct bandgap semiconductor with a bandgap size about 1.5 eV. The C, O-substituted systems are promising systems to explore two-dimensional diluted magnetic semiconductors. Magnetism is observed for C and O substitution, while for the other impurities no magnetic moment is detected. Our works paves a new route at nanoscale for novel functionalities of optical and spintronics devices.

  6. Separation of the metallic and non-metallic fraction from printed circuit boards employing green technology

    Energy Technology Data Exchange (ETDEWEB)

    Estrada-Ruiz, R.H., E-mail: rhestrada@itsaltillo.edu.mx; Flores-Campos, R., E-mail: rcampos@itsaltillo.edu.mx; Gámez-Altamirano, H.A., E-mail: hgamez@itsaltillo.edu.mx; Velarde-Sánchez, E.J., E-mail: ejvelarde@itsaltillo.edu.mx

    2016-07-05

    Highlights: • Small sizes of particles are required in order to separate the different fractions. • Inverse flotation process is an efficient green technology to separate fractions. • Superficial air velocity is the main variable in the inverse flotation process. • Inverse flotation is a green process because the pulṕs pH is 7.0 during the test. - Abstract: The generation of electrical and electronic waste is increasing day by day; recycling is attractive because of the metallic fraction containing these. Nevertheless, conventional techniques are highly polluting. The comminution of the printed circuit boards followed by an inverse flotation process is a clean technique that allows one to separate the metallic fraction from the non-metallic fraction. It was found that particle size and superficial air velocity are the main variables in the separation of the different fractions. In this way an efficient separation is achieved by avoiding the environmental contamination coupled with the possible utilization of the different fractions obtained.

  7. Strength and deformability of concrete beams reinforced by non-metallic fiber and composite rebar

    Science.gov (United States)

    Kudyakov, K. L.; Plevkov, V. S.; Nevskii, A. V.

    2015-01-01

    Production of durable and high-strength concrete structures with unique properties has always been crucial. Therefore special attention has been paid to non-metallic composite and fiber reinforcement. This article describes the experimental research of strength and deformability of concrete beams with dispersed and core fiber-based reinforcement. As composite reinforcement fiberglass reinforced plastic rods with diameters 6 mm and 10 mm are used. Carbon and basalt fibers are used as dispersed reinforcement. The developed experimental program includes designing and production of flexural structures with different parameters of dispersed fiber and composite rebar reinforcement. The preliminary testing of mechanical properties of these materials has shown their effectiveness. Structures underwent bending testing on a special bench by applying flexural static load up to complete destruction. During the tests vertical displacements were recorded, as well as value of actual load, slippage of rebars in concrete, crack formation. As a result of research were obtained structural failure and crack formation graphs, value of fracture load and maximum displacements of the beams at midspan. Analysis of experimental data showed the effectiveness of using dispersed reinforcement of concrete and the need for prestressing of fiberglass composite rebar.

  8. On-cartridge derivatisation using matrix solid phase dispersion for the determination of cyclamate in foods

    International Nuclear Information System (INIS)

    Li, Jianjun; Liu, Yun; Liu, Qianping; Hui, Junfeng; Liu, Yangzi

    2017-01-01

    A novel method for determination of sodium cyclamate in foods was developed. In this method, a syringe was loaded with the homogeneous mixture of the sample, KMnO 4 powder and silica dispersant and used as a matrix solid phase dispersion (MSPD) reactor. As the reactor was infiltrated with small amounts of concentrated HCl, cyclamate was converted to 2-chlorocyclohexanone quickly and effectively within 5 min and determined by HPLC on a reversed-phase column using UV detection at a wavelength of 310 nm. Comparing with the traditional derivatisation in solution, the better clean-up was provided using on-cartridge derivatisation of MSPD, and much time, labor, and expense were saved. The results showed good linearity (r 2  = 0.9998) over the concentration range of 1–500 mg/L. The limit of detection (LOD) and limits of quantification (LOQ) of the cyclamate were 0.3 mg/L and 1 mg/L respectively. The recoveries ranged from 91.6% to 101.3% with the relative standard deviations (RSDs) in the range of 2.5%–4.3%. - Highlights: • A novel method was developed for the determination of cyclamate in foods. • On cartridge derivatisation, using matrix solid phase dispersion, was developed. • A new derivatisation reaction for cyclamate conversion to 2-chlorocyclohexanone was developed. • The method was rapid, simple, inexpensive, effective.

  9. Thermal enhancement cartridge heater modified (TECH Mod) tritium hydride bed development, Part 1 - Design and fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J.E.; Estochen, E.G. [Savannah River National Laboratory, Aiken, SC (United States)

    2015-03-15

    The Savannah River Site (SRS) tritium facilities have used first generation (Gen1) LaNi{sub 4.25}Al{sub 0.75} (LANA0.75) metal hydride storage beds for tritium absorption, storage, and desorption. The Gen1 design utilizes hot and cold nitrogen supplies to thermally cycle these beds. Second and third generation (Gen2 and Gen3) storage bed designs include heat conducting foam and divider plates to spatially fix the hydride within the bed. For thermal cycling, the Gen2 and Gen3 beds utilize internal electric heaters and glovebox atmosphere flow over the bed inside the bed external jacket for cooling. The currently installed Gen1 beds require replacement due to tritium aging effects on the LANA0.75 material, and cannot be replaced with Gen2 or Gen3 beds due to different designs of these beds. At the end of service life, Gen1 bed desorption efficiencies are limited by the upper temperature of hot nitrogen supply. To increase end-of-life desorption efficiency, the Gen1 bed design was modified, and a Thermal Enhancement Cartridge Heater Modified (TECH Mod) bed was developed. Internal electric cartridge heaters in the new design to improve end-of-life desorption, and also permit in-bed tritium accountability (IBA) calibration measurements to be made without the use of process tritium. Additional enhancements implemented into the TECH Mod design are also discussed. (authors)

  10. On-cartridge derivatisation using matrix solid phase dispersion for the determination of cyclamate in foods

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jianjun, E-mail: bootan12@126.com [Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, Northwest University, Xi' an 710069 (China); National Engineering Research Center for Miniaturized Detection Systems, Xi' an 710069 (China); Liu, Yun [College of Food Engineering and Nutritional Science, Shaanxi Normal University, Xi' an 710062 (China); Liu, Qianping [National Engineering Research Center for Miniaturized Detection Systems, Xi' an 710069 (China); Hui, Junfeng [Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, Northwest University, Xi' an 710069 (China); Liu, Yangzi [National Engineering Research Center for Miniaturized Detection Systems, Xi' an 710069 (China)

    2017-06-15

    A novel method for determination of sodium cyclamate in foods was developed. In this method, a syringe was loaded with the homogeneous mixture of the sample, KMnO{sub 4} powder and silica dispersant and used as a matrix solid phase dispersion (MSPD) reactor. As the reactor was infiltrated with small amounts of concentrated HCl, cyclamate was converted to 2-chlorocyclohexanone quickly and effectively within 5 min and determined by HPLC on a reversed-phase column using UV detection at a wavelength of 310 nm. Comparing with the traditional derivatisation in solution, the better clean-up was provided using on-cartridge derivatisation of MSPD, and much time, labor, and expense were saved. The results showed good linearity (r{sup 2} = 0.9998) over the concentration range of 1–500 mg/L. The limit of detection (LOD) and limits of quantification (LOQ) of the cyclamate were 0.3 mg/L and 1 mg/L respectively. The recoveries ranged from 91.6% to 101.3% with the relative standard deviations (RSDs) in the range of 2.5%–4.3%. - Highlights: • A novel method was developed for the determination of cyclamate in foods. • On cartridge derivatisation, using matrix solid phase dispersion, was developed. • A new derivatisation reaction for cyclamate conversion to 2-chlorocyclohexanone was developed. • The method was rapid, simple, inexpensive, effective.

  11. Hydrogen Car Cartridges: A New Strategy for Hydrogen Storage, Delivering and Refueling

    Energy Technology Data Exchange (ETDEWEB)

    Prosini, Pier Paolo

    2007-07-01

    The purpose of the project is to introduce a sustainable model in the automotive field, guarantying the Kyoto agreements. The aim of the project is to develop an innovative hydrogen tank able to power an hydrogen fuel cell car with the same performance of liquid fuelled cars. Most of the system performance are expected to satisfy the Department of Energy (DOE) goals for 2015. The hydrogen releasing system is based on solid NaBH4 which is hydrolyzed with water or steam to obtain hydrogen. Sodium borate is obtained as by-product and it has to be recycled. Pure and humidified hydrogen, ready to be utilized in a fuel cell, is obtained by a simple and sure way. Hydrogen is produced only when it is requested and therefore there is never pressurized hydrogen or hydrogen overproduction The system works at atmospheric pressure avoiding the problems related to handling and storing pressurized gas. The car fuelling could be performed in area like the present service stations. The used cartridges can be removed and substituted by new cartridges. Contemporarily a water tank should be refilled. To improve the total energetic yield it was also proposed a NaBH4 regeneration process directly starting from the products of hydrolysis. (auth)

  12. Statistical Analysis of Firearms/Toolmarks Interpretation of Cartridge Case Evidence Using IBIS and Bayesian Networks

    Science.gov (United States)

    2015-10-24

    representations of the same surface. 54 At one stage Cambridge Instruments marketed a comparison SEM...versus-test scores (an indication of the reproducibility of marketing within the file. The solid curve represents the best-known non-match (BKNM) curve...34, "FederalAmericanEagle", "Unknown", "Unknown", "FederalAmericanEagle", "Unknown", "Remington") Primer <- c("SSG", " STP ", "SFT", "SFG", " STP ", "SSG

  13. Synthesis of O-(2-[18F]fluoroethyl)-L-tyrosine based on a cartridge purification method

    International Nuclear Information System (INIS)

    Mueller, Dirk; Klette, Ingo; Kalb, Fabrizia; Baum, Richard P.

    2011-01-01

    Introduction: O-(2-[ 18 F]fluoroethyl)-L-tyrosine (FET) is widely used as a positron emission tomography tracer for brain tumors. Usually, a high-performance liquid chromatography (HPLC) purification at the end of the two-step synthesis is applied. In this work, we report an automatic radiosynthesis of FET with a purification procedure based on standard cartridges. Methods: O-(2-[ 18 F]fluoroethyl)-L-tyrosine was prepared by [ 18 F]fluoroethylation of L-tyrosine by a two-step synthesis using a modified [ 11 C]methionine module (Nuclear Interface). In the first reaction step, we synthesized [ 18 F]fluoroethyltosylate starting from [ 18 F]fluoride. After a purification step, L-tyrosine was [ 18 F]fluoroethylated with [ 18 F]fluoroethyltosylate. The final reaction mixture was purified by means of solid phase extraction. The FET was trapped on an SCX cartridge, eluted with saline solution and trapped again on an HRX cartridge. For a second purification step, the FET was eluted from the HRX cartridge with ammonium acetate buffer and collected on two SCX cartridges followed by a washing step with water. The final product was eluted with saline solution and neutralised with 450 μl NaHCO 3 solution (8.4%). Results: The synthesis was finished after 50 min and delivered the FET in a range of 3-16 GBq. The synthesis typically yielded 41% (21 experiments) of FET (d.c.) without an HPLC purification step. The radiochemical purity ranged between 97% and 100%. Conclusion: We present a radiosynthesis of FET where the usually used HPLC purification procedure has been substituted by a purification step based on standard cartridges. This method is useful for automatic modules without an expensive HPLC purification unit and for the routine production of FET.

  14. Environmental impacts and resource losses of incinerating misplaced household special wastes (WEEE, batteries, ink cartridges and cables)

    DEFF Research Database (Denmark)

    Bigum, Marianne Kristine Kjærgaard; Damgaard, Anders; Scheutz, Charlotte

    2017-01-01

    The contribution of misplaced special waste (sWEEE, lamps, CRT, batteries, ink cartridges and cables) to environmental impacts from incineration of residual household waste was quantified through life cycle assessment (LCA)-modelling. Misplaced special waste was quantified to constitute less than 1...... and batteries. However as shown by sensitivity analysis, lack of good data on the transfer of rare and hazardous metals to the flue gas in the incineration process should receive further investigation before the environmental impacts from misplaced incinerated special waste can fully be concluded upon. Although...... special waste (sWEEE, lamps, CRT, batteries, ink cartridges, and cables)....

  15. Computer-Aided-Design of the Hydraulic System of Three-Dimensional Cartridge Valve Blocks (Selected Articles)

    Science.gov (United States)

    1991-03-21

    sectional representation of the spatial figure can be correctly determined. 6 The AutoLisp language system in the AutoCAD software provides the most...softwares are developed on the 32-bit machines and little progress has been reported for the 16-bit machines. Even the AutoCAD is a two-ard-a-half... AutoCAD software as the basis, developed the design package of 3-D cartridge valve blocks on IM PC/AT. To realize the 3-D displaying of cartridge valves

  16. Dielectric relaxations in non-metallic materials related to Y-Ba-Cu-O superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Bennani, H.; Pilet, J.C. (Lab. Instrumentation, Rennes-1 Univ., 35 (France)); Guilloux-Viry, M.; Perrin, C.; Perrin, A.; Sergent, M. (Lab. de Chimie Minerale B, C.N.R.S., 35 - Rennes (France))

    1990-10-15

    In relation with high Tc superconducting material studies, dielectric measurements have been carried out, in the frequency range 10 Hz - 100 kHz, on two powdered compounds belonging to the Y-Ba-Cu-O system. The non-metallic tetragonal phases YBa{sub 2}Cu{sub 3}O{sub 6+x} exhibit dielectric relaxations: for the studied samples (x<0.4) the activation energy U is observed in the range 0.5

  17. Novel measurement method of activation energy of non-metallic materials for NPP

    International Nuclear Information System (INIS)

    Park, Chang-Dae; Lim, Byung-Ju; Song, Chi-Sung

    2008-01-01

    This paper presents novel technique and its applicability for measuring activation energy of non-metallic materials for NPPs (nuclear power plants). The E a is a principal property for life assessment and accelerating thermal aging of equipment during environmental qualification. The E a is conventionally obtained by tensile test using UTM (Universal Testing Machine). However, this conventional method has many difficulties such as lots of big standardized specimens required and long measuring time of at least 3 months. Moreover, this is not only an inapplicable method during inservice inspection but destructive method, which are main obstacles for using UTM. Fortunately, newly developed technique for the E a such as TGA (Thermo-gravimetric Analysis) and DMA (Dynamic Mechanical Analysis) can eliminate almost all the problems of UTM. The common TGA is to measure weight change with time under constant heating rate. TGA was devised to perform the compositional analysis of materials such as rubber, carbon black, filler, volatile, etc., and to determine the thermal stability/decomposition, stoichiometry of reactions, and kinetics of reaction, by weight changes of materials when heated. TGA method has various advantages such as small amount of the sample (e.g. 20 mg), shortened measuring time of approximately 2 days, and virtually non-destructive method. In this study, we have tried to find the justification of TGA utilization for E a measurement by comparing the measured TGA data to UTM data for three cable materials. Considering reasonable consistency of our TGA data with UTM data, we conclude that TGA method gives convenient way to measure the activation energy for EPR, CR, and CSP materials with many merits, such as measuring time, specimen size and quantity required, and test expenses. (author)

  18. Thermal and Chemical Characterization of Non-Metallic Materials Using Coupled Thermogravimetric Analysis and Infrared Spectroscopy

    Science.gov (United States)

    Huff, Timothy L.

    2002-01-01

    Thermogravimetric analysis (TGA) is widely employed in the thermal characterization of non-metallic materials, yielding valuable information on decomposition characteristics of a sample over a wide temperature range. However, a potential wealth of chemical information is lost during the process, with the evolving gases generated during thermal decomposition escaping through the exhaust line. Fourier Transform-Infrared spectroscopy (FT-IR) is a powerful analytical technique for determining many chemical constituents while in any material state, in this application, the gas phase. By linking these two techniques, evolving gases generated during the TGA process are directed into an appropriately equipped infrared spectrometer for chemical speciation. Consequently, both thermal decomposition and chemical characterization of a material may be obtained in a single sample run. In practice, a heated transfer line is employed to connect the two instruments while a purge gas stream directs the evolving gases into the FT-IR. The purge gas can be either high purity air or an inert gas such as nitrogen to allow oxidative and pyrolytic processes to be examined, respectively. The FT-IR data is collected realtime, allowing continuous monitoring of chemical compositional changes over the course of thermal decomposition. Using this coupled technique, an array of diverse materials has been examined, including composites, plastics, rubber, fiberglass epoxy resins, polycarbonates, silicones, lubricants and fluorocarbon materials. The benefit of combining these two methodologies is of particular importance in the aerospace community, where newly developing materials have little available data with which to refer. By providing both thermal and chemical data simultaneously, a more definitive and comprehensive characterization of the material is possible. Additionally, this procedure has been found to be a viable screening technique for certain materials, with the generated data useful in

  19. Recycling of non-metallic fractions from waste electrical and electronic equipment (WEEE): a review.

    Science.gov (United States)

    Wang, Ruixue; Xu, Zhenming

    2014-08-01

    The world's waste electrical and electronic equipment (WEEE) consumption has increased incredibly in recent decades, which have drawn much attention from the public. However, the major economic driving force for recycling of WEEE is the value of the metallic fractions (MFs). The non-metallic fractions (NMFs), which take up a large proportion of E-wastes, were treated by incineration or landfill in the past. NMFs from WEEE contain heavy metals, brominated flame retardant (BFRs) and other toxic and hazardous substances. Combustion as well as landfill may cause serious environmental problems. Therefore, research on resource reutilization and safe disposal of the NMFs from WEEE has a great significance from the viewpoint of environmental protection. Among the enormous variety of NMFs from WEEE, some of them are quite easy to recycle while others are difficult, such as plastics, glass and NMFs from waste printed circuit boards (WPCBs). In this paper, we mainly focus on the intractable NMFs from WEEE. Methods and technologies of recycling the two types of NMFs from WEEE, plastics, glass are reviewed in this paper. For WEEE plastics, the pyrolysis technology has the lowest energy consumption and the pyrolysis oil could be obtained, but the containing of BFRs makes the pyrolysis recycling process problematic. Supercritical fluids (SCF) and gasification technology have a potentially smaller environmental impact than pyrolysis process, but the energy consumption is higher. With regard to WEEE glass, lead removing is requisite before the reutilization of the cathode ray tube (CRT) funnel glass, and the recycling of liquid crystal display (LCD) glass is economically viable for the containing of precious metals (indium and tin). However, the environmental assessment of the recycling process is essential and important before the industrialized production stage. For example, noise and dust should be evaluated during the glass cutting process. This study could contribute

  20. Chemical sensors for monitoring non-metallic impurities in liquid sodium coolant

    International Nuclear Information System (INIS)

    Ganesan, Rajesh; Jayaraman, V.; Rajan Babu, S.; Sridharan, R.; Gnanasekaran, T.

    2011-01-01

    Liquid sodium is the coolant of choice for fast breeder reactors. Liquid sodium is highly compatible with structural steels when the concentration of dissolved non-metallic impurities such as oxygen and carbon are low. However, when their concentrations are above certain threshold limits, enhanced corrosion and mass transfer and carburization of the steels would occur. The threshold concentration levels of oxygen in sodium are determined by thermochemical aspects of various ternary oxides of Na-M-O systems (M alloying elements in steels) which take part in corrosion and mass transfer. Dissolved carbon also influences these threshold levels by establishing relevant carbide equilibria. An event of steam leak into sodium at the steam generator, if undetected at its inception itself, can lead to extensive wastage of the tubes of the steam generator and prolonged shutdown. Air ingress into the argon cover gas and leak of hydrocarbon oil used as cooling fluids of the shafts of the centrifugal pumps of sodium are the sources of oxygen and carbon impurities in sodium. Continuous monitoring of the concentration of dissolved hydrogen, carbon and oxygen in sodium coolant will help identifying their ingress at inception itself. An electrochemical hydrogen sensor based on CaHBr-CaBr 2 hydride ion conducting solid electrolyte has been developed for detecting the steam leak during normal operating conditions of the reactor. A nickel diffuser based sensor system using thermal conductivity detector (TCD) and Pd-doped tin oxide thin film sensor has been developed for use during low power operations of the reactor or during its start up. For monitoring carbon in sodium, an electrochemical sensor with molten Na 2 CO 3 -LiCO 3 as the electrolyte and pure graphite as reference electrode has been developed. Yttria Doped Thoria (YDT) electrolyte based oxygen sensor is under development for monitoring dissolved oxygen levels in sodium. Fabrication, assembly, testing and performance of

  1. Detection and genotyping of human papillomavirus in self-obtained cervicovaginal samples by using the FTA cartridge: new possibilities for cervical cancer screening.

    NARCIS (Netherlands)

    Lenselink, C.H.; Bie, R.P. de; Hamont, D. van; Bakkers, J.M.J.E.; Quint, W.G.V.; Massuger, L.F.A.G.; Bekkers, R.L.M.; Melchers, W.J.G.

    2009-01-01

    This study assesses human papillomavirus (HPV) detection and genotyping in self-sampled genital smears applied to an indicating FTA elute cartridge (FTA cartridge). The study group consisted of 96 women, divided into two sample sets. All samples were analyzed by the HPV SPF(10)-Line Blot 25. Set 1

  2. Disposable cartridge extraction of retinol and alpha-tocopherol from fatty samples.

    Science.gov (United States)

    Bourgeois, C F; Ciba, N

    1988-01-01

    A new approach is proposed for liquid/solid extraction of retinol and alpha-tocopherol from samples, using a disposable kieselguhr cartridge. The substitution of the mixture methanol-ethanol-n-butanol (4 + 3 + 1) for methanol in the alkaline hydrolysis solution makes it now possible to process fatty samples. Methanol is necessary to solubilize the antioxidant ascorbic acid, and a linear chain alcohol such as n-butanol is necessary to reduce the size of soap micelles so that they can penetrate into the kieselguhr pores. In comparisons of the proposed method with conventional methods on mineral premixes and fatty feedstuffs, recovery and accuracy are at least as good by the proposed method. Advantages are increased rate of determinations and the ability to hydrolyze and extract retinol and alpha-tocopherol together from the same sample.

  3. Rapid purification of radioiodinated peptides with Sep-Pak reversed phase cartridges and HPLC

    International Nuclear Information System (INIS)

    Miller, J.J.; Schultz, G.S.; Levy, R.S.

    1984-01-01

    A simple, rapid method is described for the purification of radioiodinated peptides for use in radioimmuno- and in radioreceptor assays. Iodinated reaction mixtures are applied directly onto Sep-Pak disposable, reversed phase cartridges equilibrated with phosphate buffer. Unreacted 125-iodide and other non-peptide reaction components are eluted with buffer. The peptide fraction is then eluted with 70% buffer:30% acetonitrile. The peptide fraction is further purified by reversed phase high pressure liquid chromatography to separate the native peptide and the mono- and diiodo-derivatives. In this study the method is used to prepare 125-iodide-labeled monoiodo-leucine enkephalin and monoiodo-angiotensin II, which are free of the parent peptides and diiodo-derivatives and are of maximum obtainable specific radioactivity. The usefulness of these labeled peptides in radioimmuno- and radioreceptor assays is demonstrated by their binding to specific antibodies and receptors, respectively. (author)

  4. A new screening method for amphetamine and methamphetamine using dansyl chloride derivatization and cartridge fluorescence.

    Science.gov (United States)

    Yamada, H; Ikeda-Wada, S; Oguri, K

    1998-07-01

    A new screening method for amphetamines was developed. It consists of derivatization with dansyl chloride, extraction of the derivative using a Sep-Pak C18 or a Bond Elut C18, solid phase extraction columns, and visualization of the fluorescence of the cartridge. A control test using drug-free urine showed no fluorescence. Amphetamine, methamphetamine and the methylenedioxy derivatives exhibited strong fluorescence, while related compounds, such as N-ethylamphetamine and fenetylline, were negative or weakly positive. The disadvantage of the present method is that it is a multi-step procedure and 20-30 min is required for screening. However, since it has a different specificity from the widely used immunochemical technique, it is suggested to be a useful screen for amphetamines.

  5. Characterization of filter cartridges from the IEA-R1 reactor by radiochemical method

    International Nuclear Information System (INIS)

    Geraldo, Bianca; Vicente, Roberto; Ferreira, Robson J.; Goes, Marcos M.; Marumo, Julio T.

    2015-01-01

    The filter cartridges used in water purification system of research nuclear reactor IEA-R1 are considered radioactive wastes after their useful life. The characterization of these wastes is one of the stages of management, which aims to identify and quantify the radionuclides present, including those known as 'difficult to measure' (DTM) radionuclides. Establish a radiochemical analysis methodology for this type of waste is a difficult job, not only by the application of these techniques, but also by the amount of radionuclides that should be analyzed. In the waste produced in a nuclear reactor, the most important radionuclides are fission products, activation products and transuranic elements. Since these radionuclides emit gamma radiation not measurable in its decay process and consequently are difficult to measure, their concentrations can be estimated by indirect methods such as scale factors. This method is used to evaluate the DTM concentration, which is represented by alpha and beta nuclides using the correlation between them and the radionuclide key, a gamma emitter. The objective of this work is to describe a radiochemical analysis methodology for gamma emitter nuclides, present in the filter cartridges, evaluating the activity and concentrations by destructive assays. At the same time, two studies have been performed by non-destructive assays, the first one based on dose rates and the point kernel method to correlate the results and the second one based on calibration efficiency with Monte Carlo method. These studies belong to the radioactive waste characterization program that has been conducted at the Waste Management Laboratory of Nuclear and Energy Research Institute, IPEN-CNEN/SP. (author)

  6. Characterization of filter cartridges from the IEA-R1 reactor by radiochemical method

    Energy Technology Data Exchange (ETDEWEB)

    Geraldo, Bianca; Vicente, Roberto; Ferreira, Robson J.; Goes, Marcos M.; Marumo, Julio T., E-mail: bgeraldo@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The filter cartridges used in water purification system of research nuclear reactor IEA-R1 are considered radioactive wastes after their useful life. The characterization of these wastes is one of the stages of management, which aims to identify and quantify the radionuclides present, including those known as 'difficult to measure' (DTM) radionuclides. Establish a radiochemical analysis methodology for this type of waste is a difficult job, not only by the application of these techniques, but also by the amount of radionuclides that should be analyzed. In the waste produced in a nuclear reactor, the most important radionuclides are fission products, activation products and transuranic elements. Since these radionuclides emit gamma radiation not measurable in its decay process and consequently are difficult to measure, their concentrations can be estimated by indirect methods such as scale factors. This method is used to evaluate the DTM concentration, which is represented by alpha and beta nuclides using the correlation between them and the radionuclide key, a gamma emitter. The objective of this work is to describe a radiochemical analysis methodology for gamma emitter nuclides, present in the filter cartridges, evaluating the activity and concentrations by destructive assays. At the same time, two studies have been performed by non-destructive assays, the first one based on dose rates and the point kernel method to correlate the results and the second one based on calibration efficiency with Monte Carlo method. These studies belong to the radioactive waste characterization program that has been conducted at the Waste Management Laboratory of Nuclear and Energy Research Institute, IPEN-CNEN/SP. (author)

  7. Ways of increasing of efficiency of the use of chemical gazogene cartridges at the mining of facing raw material

    OpenAIRE

    Кальчук, Сергій Володимирович; Лукащук, Олександр Вікторович

    2016-01-01

    The analysis and theoretical generalizations of influencing of the known methods of separation to the stone on the array of breeds is executed. Certain backlogs of increase of the OIR use of chemical gazogene cartridges. Offered ways of determination of optimum parameters of most effective their applications on the deposits of facing stone.

  8. Recycling of non-metallic fractions from waste printed circuit boards: A review

    Energy Technology Data Exchange (ETDEWEB)

    Guo Jiuyong; Guo Jie [School of Environmental Science and Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240 (China); Xu Zhenming, E-mail: zmxu@sjtu.edu.cn [School of Environmental Science and Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240 (China)

    2009-09-15

    The major economic driving force for recycling of waste printed circuit boards (PCBs) is the value of the metallic fractions (MFs) of PCBs. The non-metallic fractions (NMFs), which take up almost 70 wt% of waste PCBs, were treated by combustion or land filling in the past. However, combustion of the NMFs will cause the formation of highly toxic polybrominated dibenzodioxins and dibenzofurans (PBDD/Fs) while land filling of the NMFs will lead to secondary pollution caused by heavy metals and brominated flame retardants (BFRs) leaching to the groundwater. Therefore, recycling of the NMFs from waste PCBs is drawing more and more attention from the public and the governments. Currently, how to recycle the NMFs environmental soundly has become a significant topic in recycling of waste PCBs. In order to fulfill the better resource utilization of the NMFs, the compositions and characteristics of the NMFs, methods and outcomes of recycling the NMFs from waste PCBs and analysis and treatment for the hazardous substances contained in the NMFs were reviewed in this paper. Thermosetting resin matrix composites, thermoplastic matrix composites, concrete and viscoelastic materials are main applications for physical recycling of the NMFs. Chemical recycling methods consisting of pyrolysis, gasification, supercritical fluids depolymerization and hydrogenolytic degradation can be used to convert the NMFs to chemical feedstocks and fuels. The toxicity characteristic leaching procedure (TCLP) and synthetic precipitation leaching procedure (SPLP) can be used to determine the toxicity characteristic (TC) of the NMFs and to evaluate the environmental safety of products made from the recycled NMFs. It is believed that physical recycling of the NMFs has been a promising recycling method. Much more work should be done to develop comprehensive and industrialized usage of the NMFs recycled by physical methods. Chemical recycling methods have the advantages in eliminating hazardous substances

  9. Recycling of non-metallic fractions from waste printed circuit boards: A review

    International Nuclear Information System (INIS)

    Guo Jiuyong; Guo Jie; Xu Zhenming

    2009-01-01

    The major economic driving force for recycling of waste printed circuit boards (PCBs) is the value of the metallic fractions (MFs) of PCBs. The non-metallic fractions (NMFs), which take up almost 70 wt% of waste PCBs, were treated by combustion or land filling in the past. However, combustion of the NMFs will cause the formation of highly toxic polybrominated dibenzodioxins and dibenzofurans (PBDD/Fs) while land filling of the NMFs will lead to secondary pollution caused by heavy metals and brominated flame retardants (BFRs) leaching to the groundwater. Therefore, recycling of the NMFs from waste PCBs is drawing more and more attention from the public and the governments. Currently, how to recycle the NMFs environmental soundly has become a significant topic in recycling of waste PCBs. In order to fulfill the better resource utilization of the NMFs, the compositions and characteristics of the NMFs, methods and outcomes of recycling the NMFs from waste PCBs and analysis and treatment for the hazardous substances contained in the NMFs were reviewed in this paper. Thermosetting resin matrix composites, thermoplastic matrix composites, concrete and viscoelastic materials are main applications for physical recycling of the NMFs. Chemical recycling methods consisting of pyrolysis, gasification, supercritical fluids depolymerization and hydrogenolytic degradation can be used to convert the NMFs to chemical feedstocks and fuels. The toxicity characteristic leaching procedure (TCLP) and synthetic precipitation leaching procedure (SPLP) can be used to determine the toxicity characteristic (TC) of the NMFs and to evaluate the environmental safety of products made from the recycled NMFs. It is believed that physical recycling of the NMFs has been a promising recycling method. Much more work should be done to develop comprehensive and industrialized usage of the NMFs recycled by physical methods. Chemical recycling methods have the advantages in eliminating hazardous substances

  10. Recycling of non-metallic fractions from waste electrical and electronic equipment (WEEE): A review

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ruixue; Xu, Zhenming, E-mail: zmxu@sjtu.edu.cn

    2014-08-15

    Highlights: • NMFs from WEEE were treated by incineration or land filling in the past. • Environmental risks such as heavy metals and BFRs will be the major problems during the NMFs recycling processes. • Methods and technologies of recycling the two types of NMFs from WEEE, plastics, glasses are reviewed. • More environmental impact assessment should be carried out to evaluate the environmental risks of the recycling products. - Abstract: The world’s waste electrical and electronic equipment (WEEE) consumption has increased incredibly in recent decades, which have drawn much attention from the public. However, the major economic driving force for recycling of WEEE is the value of the metallic fractions (MFs). The non-metallic fractions (NMFs), which take up a large proportion of E-wastes, were treated by incineration or landfill in the past. NMFs from WEEE contain heavy metals, brominated flame retardant (BFRs) and other toxic and hazardous substances. Combustion as well as landfill may cause serious environmental problems. Therefore, research on resource reutilization and safe disposal of the NMFs from WEEE has a great significance from the viewpoint of environmental protection. Among the enormous variety of NMFs from WEEE, some of them are quite easy to recycle while others are difficult, such as plastics, glass and NMFs from waste printed circuit boards (WPCBs). In this paper, we mainly focus on the intractable NMFs from WEEE. Methods and technologies of recycling the two types of NMFs from WEEE, plastics, glass are reviewed in this paper. For WEEE plastics, the pyrolysis technology has the lowest energy consumption and the pyrolysis oil could be obtained, but the containing of BFRs makes the pyrolysis recycling process problematic. Supercritical fluids (SCF) and gasification technology have a potentially smaller environmental impact than pyrolysis process, but the energy consumption is higher. With regard to WEEE glass, lead removing is requisite

  11. Non-Metallic Inclusions and Hot-Working Behaviour of Advanced High-Strength Medium-Mn Steels

    Directory of Open Access Journals (Sweden)

    Grajcar A.

    2016-06-01

    Full Text Available The work addresses the production of medium-Mn steels with an increased Al content. The special attention is focused on the identification of non-metallic inclusions and their modification using rare earth elements. The conditions of the thermomechanical treatment using the metallurgical Gleeble simulator and the semi-industrial hot rolling line were designed for steels containing 3 and 5% Mn. Hot-working conditions and controlled cooling strategies with the isothermal holding of steel at 400°C were selected. The effect of Mn content on the hot-working behaviour and microstructure of steel was addressed. The force-energetic parameters of hot rolling were determined. The identification of structural constituents was performed using light microscopy and scanning electron microscopy methods. The addition of rare earth elements led to the total modification of non-metallic inclusions, i.e., they replaced Mn and Al forming complex oxysulphides. The Mn content in a range between 3 and 5% does not affect the inclusion type and the hot-working behaviour. In contrast, it was found that Mn has a significant effect on a microstructure.

  12. Toward environmentally-benign utilization of nonmetallic fraction of waste printed circuit boards as modifier and precursor.

    Science.gov (United States)

    Hadi, Pejman; Ning, Chao; Ouyang, Weiyi; Xu, Meng; Lin, Carol S K; McKay, Gordon

    2015-01-01

    Electronic waste, including printed circuit boards, is growing at an alarming rate due to the accelerated technological progress and the shorter lifespan of the electronic equipment. In the past decades, due to the lack of proper economic and environmentally-benign recycling technologies, a major fraction of e-waste generated was either destined to landfills or incinerated with the sole intention of its disposal disregarding the toxic nature of this waste. Recently, with the increasing public awareness over their environment and health issues and with the enaction of more stringent regulations, environmentally-benign recycling has been driven to be an alternative option partially replacing the traditional eco-unfriendly disposal methods. One of the most favorable green technologies has been the mechanical separation of the metallic and nonmetallic fraction of the waste printed circuit boards. Although metallic fraction, as the most profitable component, is used to generate the revenue of the separation process, the nonmetallic fraction (NMF) has been left isolated. Herein, the recent developments in the application of NMF have been comprehensively reviewed and an eco-friendly emerging usage of NMF as a value-added material for sustainable remediation has been introduced. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. AES and SIMS analysis of non-metallic inclusions in a low-carbon chromium-steel.

    Science.gov (United States)

    Gammer, Katharina; Rosner, M; Poeckl, G; Hutter, H

    2003-05-01

    In the final step of secondary metallurgical steel processing, calcium is added. Besides Mg, Ca is the most powerful deoxidiser and desulfurisation agent. It reacts with dissolved oxygen and sulfur and reduces oxides and sulfides thereby forming non-metallic inclusions. Within this paper we present the analysis of such inclusions in a low-carbon chromium-steel. Depending on the time of quenching of the steel sample, different structures were revealed by REM, Auger and SIMS: If the steel was quenched immediately after Ca-addition, non-metallic inclusions that appeared to have "cavities" could be detected with SEM. SIMS investigations of these particles showed ring-shaped structures and revealed that the ring is made up of Al, Ca, Mg, O and S. No secondary ions however could be retrieved from the core inside the ring, thus leaving the nature of the "cavities" unclear. If the steel sample was quenched 3 min after Ca addition, inclusions did not have a ring-shaped structure but a compact one.

  14. The indicating FTA elute cartridge a solid sample carrier to detect high-risk HPV and high-grade cervical lesions.

    Science.gov (United States)

    de Bie, Roosmarie P; Schmeink, Channa E; Bakkers, Judith M J E; Snijders, Peter J F; Quint, Wim G V; Massuger, Leon F A G; Bekkers, Ruud L M; Melchers, Willem J G

    2011-07-01

    The clinically validated high-risk human papillomavirus (hrHPV) Hybrid Capture 2 (HC2) and GP5+/6+-PCR assays were analyzed on an Indicating FTA Elute cartridge (FTA cartridge). The FTA cartridge is a solid dry carrier that allows safe transport of cervical samples. FTA cartridge samples were compared with liquid-based samples for hrHPV and high-grade cervical intraepithelial neoplasia (CIN) detection. One cervical sample was collected in a liquid-based medium, and one was applied to the FTA cartridge. DNA was eluted directly from the FTA cartridge by a simple elution step. HC2 and GP5+/6+-PCR assays were performed on both the liquid-based and the FTA-eluted DNA of 88 women. Overall agreement between FTA and liquid-based samples for the presence of hrHPV was 90.9% with GP5+/6+-PCR and 77.3% with HC2. The sensitivity for high-grade CIN of hrHPV testing on the FTA cartridges was 84.6% with GP5+/6+-PCR and only 53.8% with HC2. By comparison, these sensitivities on liquid-based samples were 92.3% and 100% for GP5+/6+-PCR and HC2, respectively. Therefore, the FTA cartridge shows reasonably good overall agreement for hrHPV detection with liquid-based media when using GP5+/6+-PCR but not HC2 testing. Even with GP5+/6+-PCR, the FTA cartridge is not yet capable of detecting all high-grade CIN lesions. Copyright © 2011 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  15. Catalyst of a metal heteropoly acid salt that is insoluble in a polar solvent on a non-metallic porous support and method of making

    Science.gov (United States)

    Wang, Yong [Richland, WA; Peden, Charles H. F. [West Richland, WA; Choi, Saemin [Richland, WA

    2002-10-29

    The present invention includes a catalyst having (a) a non-metallic support having a plurality of pores; (b) a metal heteropoly acid salt that is insoluble in a polar solvent on the non-metallic support; wherein at least a portion of the metal heteropoly acid salt is dispersed within said plurality of pores. The present invention also includes a method of depositing a metal heteropoly acid salt that is insoluble in a polar solvent onto a non-metallic support having a plurality of pores. The method has the steps of: (a) obtaining a first solution containing a first precursor of a metal salt cation; (b) obtaining a second solution containing a second precursor of a heteropoly acid anion in a solvent having a limited dissolution potential for said first precursor; (c) impregnating the non-metallic support with the first precursor forming a first precursor deposit within the plurality of pores, forming a first precursor impregnated support; (d) heating said first precursor impregnated support forming a bonded first precursor impregnated support; (e) impregnating the second precursor that reacts with the precursor deposit and forms the metal heteropoly acid salt.

  16. Analysis of the treatment of plastic from electrical and electronic waste in the Republic of Serbia and the testing of the recycling potential of non-metallic fractions of printed circuit boards

    Directory of Open Access Journals (Sweden)

    Vučinić Aleksandra S.

    2017-01-01

    Full Text Available This paper presents the analysis of the quantity of plastic and waste printed circuit boards obtained after the mechanical treatment of electrical and electronic waste (E-waste in the Republic of Serbia, as well as the recycling of non-metallic fractions of waste printed circuit boards. The aim is to analyze the obtained recycled material and recommendation for possible application of recyclables. The data on the quantities and treatment of plastics and printed circuit boards obtained after the mechanical treatment of WEEE, were gained through questionnaires sent to the operators who treat this type of waste. The results of the questionnaire analysis showed that in 2014 the dismantling of E-waste isolated 1,870.95 t of plastic and 499.85 t of printed circuit boards. In the Republic of Serbia, E-waste recycling is performed exclusively by using mechanical methods. Mechanical methods consist of primary crushing and separation of the materials which have a utility value as secondary raw materials, from the components and materials that have hazardous properties. Respect to that, the recycling of printed circuit boards using some of the metallurgical processes with the aim of extracting copper, precious metals and non-metallic fraction is completely absent, and the circuit boards are exported as a whole. Given the number of printed circuit boards obtained by E-waste dismantling, and the fact that from an economic point of view, hydrometallurgical methods are very suitable technological solutions in the case of a smaller capacity, there is a possibility for establishing the facilities in the Republic of Serbia for the hydrometallurgical treatment that could be used for metals extraction, and non-metallic fractions, which also have their own value. Printed circuit boards granulate obtained after the mechanical pretreatment and the selective removal of metals by hydrometallurgical processes was used for the testing of the recycling potential

  17. Coagulation measurement from whole blood using vibrating optical fiber in a disposable cartridge.

    Science.gov (United States)

    Yaraş, Yusuf Samet; Gündüz, Ali Bars; Sağlam, Gökhan; Ölçer, Selim; Civitçi, Fehmi; Baris, İbrahim; Yaralioğlu, Göksenin; Urey, Hakan

    2017-11-01

    In clinics, blood coagulation time measurements are performed using mechanical measurements with blood plasma. Such measurements are challenging to do in a lab-on-a-chip (LoC) system using a small volume of whole blood. Existing LoC systems use indirect measurement principles employing optical or electrochemical methods. We developed an LoC system using mechanical measurements with a small volume of whole blood without requiring sample preparation. The measurement is performed in a microfluidic channel where two fibers are placed inline with a small gap in between. The first fiber operates near its mechanical resonance using remote magnetic actuation and immersed in the sample. The second fiber is a pick-up fiber acting as an optical sensor. The microfluidic channel is engineered innovatively such that the blood does not block the gap between the vibrating fiber and the pick-up fiber, resulting in high signal-to-noise ratio optical output. The control plasma test results matched well with the plasma manufacturer's datasheet. Activated-partial-thromboplastin-time tests were successfully performed also with human whole blood samples, and the method is proven to be effective. Simplicity of the cartridge design and cost of readily available materials enable a low-cost point-of-care device for blood coagulation measurements. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  18. Unsuitability of using the DNPH-coated solid sorbent cartridge for determination of airborne unsaturated carbonyls

    Science.gov (United States)

    Ho, Steven Sai Hang; Ho, K. F.; Liu, W. D.; Lee, S. C.; Dai, W. T.; Cao, J. J.; Ip, H. S. S.

    2011-01-01

    Measurements of aldehydes and ketones are typically conducted by derivatization using sorbent cartridges coated with 2,4-dinitrophenylhydrazine (DNPH). The collected samples are eluted with acetonitrile and analyzed by high-pressure liquid chromatography coupled with an ultra-violet detector (HPLC/UV). This paper intends to examine artifacts about its suitability in identification of unsaturated carbonyls. Kinetic tests for acrolein, crotonaldehyde, methacrolein and methyl vinyl ketone (MVK) showed formations of carbonyl-DNP-hydrazone during sampling, which could further react with DNPH, resulting in undesired UV absorption products [e.g., carbonyl-DNP-hydrazone-DNPH (dimer) and 2(carbonyl-DNP-hydrazone)-DNPH (trimer)]. The dimerization and trimerization occurred for acrolein and MVK whereas only dimerization for crotonaldehyde and methacrolein. The polymerization products undoubtedly affect the integrity of the chromatogram, leading to misidentification and inaccurate quantification. Whether precautions taken during sampling and/or sample treatment could avoid or minimize this artifact has not been thoughtfully investigated. More often, such artifacts are usually overlooked by scientists when the data are reported.

  19. Microfluidic impact printer with interchangeable cartridges for versatile non-contact multiplexed micropatterning.

    Science.gov (United States)

    Ding, Yuzhe; Huang, Eric; Lam, Kit S; Pan, Tingrui

    2013-05-21

    Biopatterning has been increasingly used for well-defined cellular microenvironment, patterned surface topology, and guided biological cues; however, it meets challenges on biocompatibility, thermal and chemical sensitivity, as well as limited availability of reagents. In this paper, we aim at combining the desired features from non-contact inkjet printing and dot-matrix impact printing to establish a versatile multiplexed micropatterning platform, referred to as Microfluidic Impact Printer (MI-Printer), for emerging biomedical applications. Using this platform, we can achieve the distinct features of no cross-contamination, sub-microliter ink loading with a minimal dead volume, high-throughput printing, biocompatible non-contact processing, sequential patterning with self-alignment, wide adaptability for complex media (e.g., cell suspension or colloidal solutions), interchangeable/disposable cartridge design, and simple assembly and configuration, all highly desirable towards laboratory-based research and development. Specifically, the printing resolution of the MI-printer platform has been experimentally characterized and theoretically analysed. Optimal printing resolution of 80 μm has been repeatedly obtained. Furthermore, two useful functions of the MI-printer, multiplexed printing and combinatorial printing, have been experimentally demonstrated with less than 10 μm misalignment. Moreover, molecular and biological patterning, utilizing the multiplexed and combinatorial printing, has been implemented to illustrate the utility of this versatile printing technique for emerging biomedical applications.

  20. Double versus single cartridge of 4% articaine infiltration into the retro-molar area for lower third molar surgery.

    Science.gov (United States)

    Sawang, Kamonpun; Chaiyasamut, Teeranut; Kiattavornchareon, Sirichai; Pairuchvej, Verasak; Bhattarai, Bishwa Prakash; Wongsirichat, Natthamet

    2017-06-01

    There are no studies regarding 4% articaine infiltration injection into the retro-molar area for an impacted lower third molar (LITM) surgery. This study aimed to evaluate the efficacy of infiltration using 1.7 ml (single cartridge: SC) of 4% articaine versus 3.4 ml (double cartridges: DC) of 4% articaine with 1:100,000 epinephrine in LITM surgery. This study involved 30 healthy patients with symmetrical LITM. The patients were assigned to receive either a DC or SC of 4% articaine with 1:100,000 epinephrine as a local anesthetic for each operation. Onset, duration, profoundness, need for additional anesthetic administration, total volume of anesthetic used, vitality of the tooth, and pain score during operation were recorded. The DC of 4 % articaine had a significantly higher success rate (83.3%) than did the SC (53.3%; P molar region can be an alternative anesthetic for LITM surgery.

  1. The security management of spent filter cartridge in Qinshan phase 3 (heavy water reactor) nuclear power plant

    International Nuclear Information System (INIS)

    Xue Dahai

    2005-01-01

    Qinshan phase 3 nuclear power plant is the first CANDU plant that China fetched in from Canada, and both two units operate under well condition up to now. The radioactive wastes produced during the unit operation mainly include technical waste, spent resin, and spent filter cartridge. The spent filter cartridge is one important part both in the volume and radioactivity of the radioactive waste, and it is the important content of radioactive waste management. Different from PWR, part of high radioactive spent filter in CANDU unit comes from heavy water system such as moderator system. It has to be dried through blowing before replaced from the system. But this working procedure result the filtrate dreg become flexible, and it can bring on the risk of internal or external exposure. It is very important to pay high attention to control the contamination spread during spent filter inside transfer. (authors)

  2. Randomized Comparison of Two Vaginal Self-Sampling Methods for Human Papillomavirus Detection: Dry Swab versus FTA Cartridge

    OpenAIRE

    Catarino, Rosa; Vassilakos, Pierre; Bilancioni, Aline; Vanden Eynde, Mathieu; Meyer-Hamme, Ulrike; Menoud, Pierre-Alain; Guerry, Fr?d?ric; Petignat, Patrick

    2015-01-01

    Background Human papillomavirus (HPV) self-sampling (self-HPV) is valuable in cervical cancer screening. HPV testing is usually performed on physician-collected cervical smears stored in liquid-based medium. Dry filters and swabs are an alternative. We evaluated the adequacy of self-HPV using two dry storage and transport devices, the FTA cartridge and swab. Methods A total of 130 women performed two consecutive self-HPV samples. Randomization determined which of the two tests was performed f...

  3. Development and Preliminary Assessment of Hemoperfusion Cartridge with Tannic Acid for Toxic Proteins' Precipitation: An In Vitro Model

    Directory of Open Access Journals (Sweden)

    Valquíria Miwa Hanai Yoshida

    2016-09-01

    Full Text Available Charcoal hemoperfusion (CHP is one of the extracorporeal removal techniques that are used to remove toxins from the body. CHP generally is considered the preferred method for extracorporeal extraction of several toxins—toxins that are adsorbed by activated charcoal. Assessments of the tannic acid's protective effects on ophidian poisoning are associated with the toxic proteins' precipitation by tannic acid. The challenge in treating a snakebite lies in removing the injected poison with minimal damage to blood constituent proteins. An alternative is CHP, and this investigation proposed to develop a column for hemoperfuser cartridge, combining charcoal granules trapped between layers of polymeric material conjugated to tannic acid, using an in vitro model scaled to the Wistar rat, which can be tested in an animal model. The cartridge was evaluated using the 22 full factorial design, in duplicate, as a method to study the effects of granulated-charcoal size and tannic acid concentration on the hematologic profile (platelet and leukocyte counts and biochemical profile (total serum protein and albumin dosages of sheep blood. The results demonstrate that charcoal in hemoperfuser cartridge: (1 decreases the serum in sheep blood volume, as consequence, (2 increases the serum proteins' concentration, and (iii exerts slight influence on albumin. The inclusion of tannic acid in hemoperfuser column precipitates some of serum proteins and albumin, decreasing their concentrations in the plasma serum. In conclusion, based on these effects we can suggest the use of 0.02 g tannic acid concentration and 8–20 mesh granulated charcoal in hemoperfuser cartridge for precipitating toxic proteins from snake venoms.

  4. Characteristics and Modification of Non-metallic Inclusions in Titanium-Stabilized AISI 409 Ferritic Stainless Steel

    Science.gov (United States)

    Kruger, Dirk; Garbers-Craig, Andrie

    2017-06-01

    This study describes an investigation into the improvement of castability, final surface quality and formability of titanium-stabilized AISI 409 ferritic stainless steel on an industrial scale. Non-metallic inclusions found in this industrially produced stainless steel were first characterized using SEM-EDS analyses through the INCA-Steel software platform. Inclusions were found to consist of a MgO·Al2O3 spinel core, which acted as heterogeneous nucleation site for titanium solubility products. Plant-scale experiments were conducted to either prevent the formation of spinel, or to modify it by calcium treatment. Modification to spherical dual-phase spinel-liquid matrix inclusions was achieved with calcium addition, which eliminated submerged entry nozzle clogging for this grade. Complete modification to homogeneous liquid calcium aluminates was achieved at high levels of dissolved aluminum. A mechanism was suggested to explain the extent of modification achieved.

  5. Standard practice for process compensated resonance testing via swept sine input for metallic and Non-Metallic parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice describes a general procedure for using the process compensated resonance testing (PCRT) via swept sine input method to identify metallic and non-metallic parts’ resonant pattern differences that can be used to indentify parts with anomalies causing deficiencies in the expected performance of the part in service. This practice is intended for use with instruments capable of exciting, measuring, recording, and analyzing multiple whole body mechanical vibration resonant frequencies within parts exhibiting acoustical ringing in the audio, or ultrasonic, resonant frequency ranges, or both. PCRT is used in the presence of manufacturing process variance to distinguish acceptable parts from those containing significant anomalies in physical characteristics expected to significantly alter the performance. Such physical characteristics include, but are not limited to, cracks, voids, porosity, shrink, inclusions, discontinuities, grain and crystalline structure differences, density related anomalies...

  6. Removal of Non-metallic Inclusions from Nickel Base Superalloys by Electromagnetic Levitation Melting in a Slag

    Science.gov (United States)

    Manjili, Mohsen Hajipour; Halali, Mohammad

    2018-02-01

    Samples of INCONEL 718 were levitated and melted in a slag by the application of an electromagnetic field. The effects of temperature, time, and slag composition on the inclusion content of the samples were studied thoroughly. Samples were compared with the original alloy to study the effect of the process on inclusions. Size, shape, and chemical composition of remaining non-metallic inclusions were investigated. The samples were prepared by Standard Guide for Preparing and Evaluating Specimens for Automatic Inclusion Assessment of Steel (ASTM E 768-99) method and the results were reported by means of the Standard Test Methods for Determining the Inclusion Content of Steel (ASTM E 45-97). Results indicated that by increasing temperature and processing time, greater level of cleanliness could be achieved, and numbers and size of the remaining inclusions decreased significantly. It was also observed that increasing calcium fluoride content of the slag helped reduce inclusion content.

  7. Ferromagnetism and nonmetallic transport of thin-film α-FeSi(2): a stabilized metastable material.

    Science.gov (United States)

    Cao, Guixin; Singh, D J; Zhang, X-G; Samolyuk, German; Qiao, Liang; Parish, Chad; Jin, Ke; Zhang, Yanwen; Guo, Hangwen; Tang, Siwei; Wang, Wenbin; Yi, Jieyu; Cantoni, Claudia; Siemons, Wolter; Payzant, E Andrew; Biegalski, Michael; Ward, T Z; Mandrus, David; Stocks, G M; Gai, Zheng

    2015-04-10

    A metastable phase α-FeSi_{2} was epitaxially stabilized on a silicon substrate using pulsed laser deposition. Nonmetallic and ferromagnetic behaviors are tailored on α-FeSi_{2} (111) thin films, while the bulk material of α-FeSi_{2} is metallic and nonmagnetic. The transport property of the films renders two different conducting states with a strong crossover at 50 K, which is accompanied by the onset of a ferromagnetic transition as well as a substantial magnetoresistance. These experimental results are discussed in terms of the unusual electronic structure of α-FeSi_{2} obtained within density functional calculations and Boltzmann transport calculations with and without strain. Our finding sheds light on achieving ferromagnetic semiconductors through both their structure and doping tailoring, and provides an example of a tailored material with rich functionalities for both basic research and practical applications.

  8. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens.

    Science.gov (United States)

    Guan, Yaoyao; Gravitt, Patti E; Howard, Roslyn; Eby, Yolanda J; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E

    2013-04-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p=0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Characterization of the water filters cartridges from the iea-r1 reactor using the Monte Carlo method

    International Nuclear Information System (INIS)

    Costa, Priscila; Potiens Junior, Ademar J.

    2015-01-01

    Filter cartridges are part of the primary water treatment system of the IEA-R1 Research Reactor and, when saturated, they are replaced and become radioactive waste. The IEA-R1 is located at the Nuclear and Energy Research Institute (IPEN), in Sao Paulo, Brazil. The primary characterization is the main step of the radioactive waste management in which the physical, chemical and radiological properties are determined. It is a very important step because the information obtained in this moment enables the choice of the appropriate management process and the definition of final disposal options. In this paper, it is presented a non-destructive method for primary characterization, using the Monte Carlo method associated with the gamma spectrometry. Gamma spectrometry allows the identification of radionuclides and their activity values. The detection efficiency is an important parameter, which is related to the photon energy, detector geometry and the matrix of the sample to be analyzed. Due to the difficult to obtain a standard source with the same geometry of the filter cartridge, another technique is necessary to calibrate the detector. The technique described in this paper uses the Monte Carlo method for primary characterization of the IEA-R1 filter cartridges. (author)

  10. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens

    Science.gov (United States)

    Guan, YaoYao; Gravitt, Patti E.; Howard, Roslyn; Eby, Yolanda J.; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E.

    2016-01-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p = 0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. PMID:23370404

  11. Integration of an Optical Ring Resonator Biosensor into a Self-Contained Microfluidic Cartridge with Active, Single-Shot Micropumps

    Directory of Open Access Journals (Sweden)

    Sascha Geidel

    2016-09-01

    Full Text Available While there have been huge advances in the field of biosensors during the last decade, their integration into a microfluidic environment avoiding external tubing and pumping is still neglected. Herein, we show a new microfluidic design that integrates multiple reservoirs for reagent storage and single-use electrochemical pumps for time-controlled delivery of the liquids. The cartridge has been tested and validated with a silicon nitride-based photonic biosensor incorporating multiple optical ring resonators as sensing elements and an immunoassay as a potential target application. Based on experimental results obtained with a demonstration model, subcomponents were designed and existing protocols were adapted. The newly-designed microfluidic cartridges and photonic sensors were separately characterized on a technical basis and performed well. Afterwards, the sensor was functionalized for a protein detection. The microfluidic cartridge was loaded with the necessary assay reagents. The integrated pumps were programmed to drive the single process steps of an immunoassay. The prototype worked selectively, but only with a low sensitivity. Further work must be carried out to optimize biofunctionalization of the optical ring resonators and to have a more suitable flow velocity progression to enhance the system’s reproducibility.

  12. Domestic Preparedness: Phase 2 Sarin Vapor Challenge and Corn Oil Protection Factor (PF) Testing of Commercial Powered Air Purifying Respirator (PAPR) Systems and Cartridges

    National Research Council Canada - National Science Library

    Campbell, Lee E; Lins, Ray; Pappas, Alex G

    2002-01-01

    .... Results indicate that cartridges provide complete penetration resistance against 200 mg/m3 GB challenge concentrations for 60 minutes, but that unacceptably high levels of GB vapor and corn oil...

  13. Combining cationic and anionic mixed-mode sorbents in a single cartridge to extract basic and acidic pharmaceuticals simultaneously from environmental waters.

    Science.gov (United States)

    Salas, Daniela; Borrull, Francesc; Fontanals, Núria; Marcé, Rosa Maria

    2018-01-01

    The aim of the present study is to broaden the applications of mixed-mode ion-exchange solid-phase extraction sorbents to extract both basic and acidic compounds simultaneously by combining the sorbents in a single cartridge and developing a simplified extraction procedure. Four different cartridges containing negative and positive charges in the same configuration were evaluated and compared to extract a group of basic, neutral, and acidic pharmaceuticals selected as model compounds. After a thorough optimization of the extraction conditions, the four different cartridges showed to be capable of retaining basic and acidic pharmaceuticals simultaneously through ionic interactions, allowing the introduction of a washing step with 15 mL methanol to eliminate interferences retained by hydrophobic interactions. Using the best combined cartridge, a method was developed, validated, and further applied to environmental waters to demonstrate that the method is promising for the extraction of basic and acidic compounds from very complex samples.

  14. The uncertainties calculation of acoustic method for measurement of dissipative properties of heterogeneous non-metallic materials

    Directory of Open Access Journals (Sweden)

    Мaryna O. Golofeyeva

    2015-12-01

    Full Text Available The effective use of heterogeneous non-metallic materials and structures needs measurement of reliable values of dissipation characteristics, as well as common factors of their change during the loading process. Aim: The aim of this study is to prepare the budget for measurement uncertainty of dissipative properties of composite materials. Materials and Methods: The method used to study the vibrational energy dissipation characteristics based on coupling of vibrations damping decrement and acoustic velocity in a non-metallic heterogeneous material is reviewed. The proposed method allows finding the dependence of damping on vibrations amplitude and frequency of strain-stress state of material. Results: Research of the accuracy of measurement method during the definition of decrement attenuation of fluctuations in synthegran was performed. The international approach for evaluation of measurements quality is used. It includes the common practice international rules for uncertainty expression and their summation. These rules are used as internationally acknowledged confidence measure to the measurement results, which includes testing. The uncertainties budgeting of acoustic method for measurement of dissipative properties of materials were compiled. Conclusions: It was defined that there are two groups of reasons resulting in errors during measurement of materials dissipative properties. The first group of errors contains of parameters changing of calibrated bump in tolerance limits, displacement of sensor in repeated placement to measurement point, layer thickness variation of contact agent because of irregular hold-down of resolvers to control surface, inaccuracy in reading and etc. The second group of errors is linked with density and Poisson’s ratio measurement errors, distance between sensors, time difference between signals of vibroacoustic sensors.

  15. Detection and Genotyping of Human Papillomavirus in Self-Obtained Cervicovaginal Samples by Using the FTA Cartridge: New Possibilities for Cervical Cancer Screening ▿

    Science.gov (United States)

    Lenselink, Charlotte H.; de Bie, Roosmarie P.; van Hamont, Dennis; Bakkers, Judith M. J. E.; Quint, Wim G. V.; Massuger, Leon F. A. G.; Bekkers, Ruud L. M.; Melchers, Willem J. G.

    2009-01-01

    This study assesses human papillomavirus (HPV) detection and genotyping in self-sampled genital smears applied to an indicating FTA elute cartridge (FTA cartridge). The study group consisted of 96 women, divided into two sample sets. All samples were analyzed by the HPV SPF10-Line Blot 25. Set 1 consisted of 45 women attending the gynecologist; all obtained a self-sampled cervicovaginal smear, which was applied to an FTA cartridge. HPV results were compared to a cervical smear (liquid based) taken by a trained physician. Set 2 consisted of 51 women who obtained a self-sampled cervicovaginal smear at home, which was applied to an FTA cartridge and to a liquid-based medium. DNA was obtained from the FTA cartridges by simple elution as well as extraction. Of all self-obtained samples of set 1, 62.2% tested HPV positive. The overall agreement between self- and physician-obtained samples was 93.3%, in favor of the self-obtained samples. In sample set 2, 25.5% tested HPV positive. The overall agreement for high-risk HPV presence between the FTA cartridge and liquid-based medium and between DNA elution and extraction was 100%. This study shows that HPV detection and genotyping in self-obtained cervicovaginal samples applied to an FTA cartridge is highly reliable. It shows a high level of overall agreement with HPV detection and genotyping in physician-obtained cervical smears and liquid-based self-samples. DNA can be obtained by simple elution and is therefore easy, cheap, and fast. Furthermore, the FTA cartridge is a convenient medium for collection and safe transport at ambient temperatures. Therefore, this method may contribute to a new way of cervical cancer screening. PMID:19553570

  16. Detection and genotyping of human papillomavirus in self-obtained cervicovaginal samples by using the FTA cartridge: new possibilities for cervical cancer screening.

    Science.gov (United States)

    Lenselink, Charlotte H; de Bie, Roosmarie P; van Hamont, Dennis; Bakkers, Judith M J E; Quint, Wim G V; Massuger, Leon F A G; Bekkers, Ruud L M; Melchers, Willem J G

    2009-08-01

    This study assesses human papillomavirus (HPV) detection and genotyping in self-sampled genital smears applied to an indicating FTA elute cartridge (FTA cartridge). The study group consisted of 96 women, divided into two sample sets. All samples were analyzed by the HPV SPF(10)-Line Blot 25. Set 1 consisted of 45 women attending the gynecologist; all obtained a self-sampled cervicovaginal smear, which was applied to an FTA cartridge. HPV results were compared to a cervical smear (liquid based) taken by a trained physician. Set 2 consisted of 51 women who obtained a self-sampled cervicovaginal smear at home, which was applied to an FTA cartridge and to a liquid-based medium. DNA was obtained from the FTA cartridges by simple elution as well as extraction. Of all self-obtained samples of set 1, 62.2% tested HPV positive. The overall agreement between self- and physician-obtained samples was 93.3%, in favor of the self-obtained samples. In sample set 2, 25.5% tested HPV positive. The overall agreement for high-risk HPV presence between the FTA cartridge and liquid-based medium and between DNA elution and extraction was 100%. This study shows that HPV detection and genotyping in self-obtained cervicovaginal samples applied to an FTA cartridge is highly reliable. It shows a high level of overall agreement with HPV detection and genotyping in physician-obtained cervical smears and liquid-based self-samples. DNA can be obtained by simple elution and is therefore easy, cheap, and fast. Furthermore, the FTA cartridge is a convenient medium for collection and safe transport at ambient temperatures. Therefore, this method may contribute to a new way of cervical cancer screening.

  17. Rapid and sensitive determination of phenylurea herbicides in water in the presence of their anilines by extraction with a Carbopack cartridge followed by liquid chromatography.

    Science.gov (United States)

    Di Corcia, A; Marchetti, M

    1991-03-22

    A rapid and sensitive method for determining phenylurea herbicides in environmental aqueous samples in the presence of their anilines is described. The water sample is preconcentrated by passage at a flow-rate of ca. 150 ml/min through a 250-mg graphitized carbon black (Carbopack B) cartridge. After washing with 0.6 ml of methanol, the Carbopack B trap is connected with a cartridge containing a strong cation exchanger. Organics trapped by the Carbopack cartridge are eluted by passage of 6 ml of methylene chloride-methanol (95:5, v/v). Anilines and other basic compounds are quantitatively subtracted from the solvent system while flowing through the cation-exchange cartridge. After evaporation and redissolution, the sample is subjected to reversed-phase gradient elution high-performance liquid chromatography with UV detection at 250 nm. Recoveries of phenylureas added to water at levels between 30 and 3000 ng/l were higher than 92%. The limit of detection was about 1 ng/l, for a 2-1 sample. With respect to an octadecyl (C18)-bonded silica cartridge, the Carbopack B cartridge had a far better extraction efficiency for polar phenylureas.

  18. {sup 14}CO{sub 2} processing using an improved and robust molecular sieve cartridge

    Energy Technology Data Exchange (ETDEWEB)

    Wotte, Anja, E-mail: Anja.Wotte@uni-koeln.de [Institute of Geology and Mineralogy, University of Cologne, Cologne (Germany); Wordell-Dietrich, Patrick [Thünen Institute of Climate-Smart Agriculture, Braunschweig (Germany); Wacker, Lukas [Ion Beam Physics, ETH Zurich, Zurich (Switzerland); Don, Axel [Thünen Institute of Climate-Smart Agriculture, Braunschweig (Germany); Rethemeyer, Janet [Institute of Geology and Mineralogy, University of Cologne, Cologne (Germany)

    2017-06-01

    Radiocarbon ({sup 14}C) analysis on CO{sub 2} can provide valuable information on the carbon cycle as different carbon pools differ in their {sup 14}C signature. While fresh, biogenic carbon shows atmospheric {sup 14}C concentrations, fossil carbon is {sup 14}C free. As shown in previous studies, CO{sub 2} can be collected for {sup 14}C analysis using molecular sieve cartridges (MSC). These devices have previously been made of plastic and glass, which can easily be damaged during transport. We thus constructed a robust MSC suitable for field application under tough conditions or in remote areas, which is entirely made of stainless steel. The new MSC should also be tight over several months to allow long sampling campaigns and transport times, which was proven by a one year storage test. The reliability of the {sup 14}CO{sub 2} results obtained with the MSC was evaluated by detailed tests of different procedures to clean the molecular sieve (zeolite type 13X) and for the adsorption and desorption of CO{sub 2} from the zeolite using a vacuum rig. We show that the {sup 14}CO{sub 2} results are not affected by any contamination of modern or fossil origin, cross contamination from previous samples, and by carbon isotopic fractionation. In addition, we evaluated the direct CO{sub 2} transfer from the MSC into the automatic graphitization equipment AGE with the subsequent {sup 14}C AMS analysis as graphite. This semi-automatic approach can be fully automated in the future, which would allow a high sample throughput. We obtained very promising, low blank values between 0.0018 and 0.0028 F{sup 14}C (equivalent to 50,800 and 47,200 yrs BP), which are within the analytical background and lower than results obtained in previous studies.

  19. "1"4CO_2 processing using an improved and robust molecular sieve cartridge

    International Nuclear Information System (INIS)

    Wotte, Anja; Wordell-Dietrich, Patrick; Wacker, Lukas; Don, Axel; Rethemeyer, Janet

    2017-01-01

    Radiocarbon ("1"4C) analysis on CO_2 can provide valuable information on the carbon cycle as different carbon pools differ in their "1"4C signature. While fresh, biogenic carbon shows atmospheric "1"4C concentrations, fossil carbon is "1"4C free. As shown in previous studies, CO_2 can be collected for "1"4C analysis using molecular sieve cartridges (MSC). These devices have previously been made of plastic and glass, which can easily be damaged during transport. We thus constructed a robust MSC suitable for field application under tough conditions or in remote areas, which is entirely made of stainless steel. The new MSC should also be tight over several months to allow long sampling campaigns and transport times, which was proven by a one year storage test. The reliability of the "1"4CO_2 results obtained with the MSC was evaluated by detailed tests of different procedures to clean the molecular sieve (zeolite type 13X) and for the adsorption and desorption of CO_2 from the zeolite using a vacuum rig. We show that the "1"4CO_2 results are not affected by any contamination of modern or fossil origin, cross contamination from previous samples, and by carbon isotopic fractionation. In addition, we evaluated the direct CO_2 transfer from the MSC into the automatic graphitization equipment AGE with the subsequent "1"4C AMS analysis as graphite. This semi-automatic approach can be fully automated in the future, which would allow a high sample throughput. We obtained very promising, low blank values between 0.0018 and 0.0028 F"1"4C (equivalent to 50,800 and 47,200 yrs BP), which are within the analytical background and lower than results obtained in previous studies.

  20. Growth and Filling Regularities of Filamentary Channels in Non-Metallic Inorganic Coatings Under Anodic Oxidation of Valve Metals. Mathematical Modeling

    Science.gov (United States)

    Mamaev, A. I.; Mamaeva, V. A.; Kolenchin, N. F.; Chubenko, A. K.; Kovalskaya, Ya. B.; Dolgova, Yu. N.; Beletskaya, E. Yu.

    2015-12-01

    Theoretical models are developed for growth and filling processes in filamentary channels of nanostructured non-metallic coatings produced by anodizing and microplasma oxidation. Graphical concentration distributions are obtained for channel-reacting anions, cations, and sparingly soluble reaction products depending on the time of electric current transmission and the length of the filamentary channel. Graphical distributions of the front moving velocity for the sparingly soluble compound are presented. The resulting model representation increases the understanding of the anodic process nature and can be used for a description and prediction of porous anodic film growth and filling. It is shown that the character of the filamentary channel growth and filling causes a variety of processes determining the textured metal - nonmetallic inorganic coating phase boundary formation.

  1. Effect of inhomogeneous distribution of non-metallic inclusions on crack path deflection in G42CrMo4 steel at different loading rates

    Directory of Open Access Journals (Sweden)

    S. Henschel

    2015-10-01

    Full Text Available An inhomogeneous distribution of non-metallic inclusions can result from the steel casting process. The aim of the present study was to investigate the damaging effect of an inhomogeneous distribution of nonmetallic inclusions on the crack extension behavior. To this end, the fracture toughness behavior in terms of quasi-static J-a curves was determined at room temperature. Additionally, dynamic fracture mechanics tests in an instrumented Charpy impact-testing machine were performed. The fracture surface of fracture mechanics specimens was analyzed by means of scanning electron microscopy. It was shown that an inhomogeneous distribution significantly affected the path and, therefore, the plane of crack growth. Especially clusters of non-metallic inclusions with a size of up to 200 μm exhibited a very low crack growth resistance. Due to the damaging effect of the clusters, the growing crack was strongly deflected towards the cluster. Furthermore, crack tip blunting was completely inhibited when inclusions were located at the fatigue precrack tip. Due to the large size of the non-metallic inclusion clusters, the height difference introduced by crack path deflection was significantly larger than the stretch zone height due to the crack tip blunting. However, the crack path deflection introduced by a cluster was not associated with a toughness increasing mechanism. The e dynamic loading ( 1 0.5 5 s MPam 10   K did not result in a transition from ductile fracture to brittle fracture. However, the crack growth resistance decreased with increased loading rate. This was attributed to the higher portion of relatively flat regions where the dimples were less distinct.

  2. Characterization of filters cartridges from the water polishing system of IEA-R1 reactor: radiometric methods

    International Nuclear Information System (INIS)

    Tessaro, Ana Paula G.; Vicente, Roberto

    2015-01-01

    The acceptance of radioactive waste in a repository depends primarily on knowledge of the radioisotopic inventory of the material, according to regulations established by regulatory agencies. The primary characterization is also a fundamental action to determine further steps in the management of the radioactive wastes. The aim of this work is to report the development of non-destructive methods for primary characterization of filters cartridges discarded as radioactive waste. The filters cartridges are used in the water polishing system of the IEA-R1 reactor retaining the particles in suspension in the reactor cooling water. The IEA-R1 is a pool type reactor with a thermal power of 5 MW, moderated and cooled with light water. It is located in the Energy and Nuclear Research Institute (IPEN-CNEN), in São Paulo, Brazil. The cartridge filters become radioactive waste when they are saturated and do not meet the required flow for the proper operation of the water polishing system. The activities of gamma emitters present in the filters are determined using gamma spectrometry, dose rate measurements and the Point Kernel Method to correlate results from both measurements. For the primary characterization, one alternative method is the radiochemical analysis of slices taken from each filter, what presents the disadvantage of higher exposures personnel and contamination risks. Another alternative method is the calibration of the measurement geometry of a gamma spectrometer, which requires the production of a standard filter. Both methods are necessary but can not be used in operational routine of radioactive waste management owing to cost and complexity. The method described can be used to determine routinely the radioactive inventory of these filters and other radioactive wastes, avoiding the necessity of destructive radiochemical analysis, or the necessity of calibrating the geometry of measurement. (author)

  3. A longitudinal evaluation of performance of automated BCR-ABL1 quantitation using cartridge-based detection system.

    Science.gov (United States)

    Enjeti, Anoop; Granter, Neil; Ashraf, Asma; Fletcher, Linda; Branford, Susan; Rowlings, Philip; Dooley, Susan

    2015-10-01

    An automated cartridge-based detection system (GeneXpert; Cepheid) is being widely adopted in low throughput laboratories for monitoring BCR-ABL1 transcript in chronic myelogenous leukaemia. This Australian study evaluated the longitudinal performance specific characteristics of the automated system.The automated cartridge-based system was compared prospectively with the manual qRT-PCR-based reference method at SA Pathology, Adelaide, over a period of 2.5 years. A conversion factor determination was followed by four re-validations. Peripheral blood samples (n = 129) with international scale (IS) values within detectable range were selected for assessment. The mean bias, proportion of results within specified fold difference (2-, 3- and 5-fold), the concordance rate of major molecular remission (MMR) and concordance across a range of IS values on paired samples were evaluated.The initial conversion factor for the automated system was determined as 0.43. Except for the second re-validation, where a negative bias of 1.9-fold was detected, all other biases fell within desirable limits. A cartridge-specific conversion factor and efficiency value was introduced and the conversion factor was confirmed to be stable in subsequent re-validation cycles. Concordance with the reference method/laboratory at >0.1-≤10 IS was 78.2% and at ≤0.001 was 80%, compared to 86.8% in the >0.01-≤0.1 IS range. The overall and MMR concordance were 85.7% and 94% respectively, for samples that fell within ± 5-fold of the reference laboratory value over the entire period of study.Conversion factor and performance specific characteristics for the automated system were longitudinally stable in the clinically relevant range, following introduction by the manufacturer of lot specific efficiency values.

  4. Sugar microanalysis by HPLC with benzoylation: improvement via introduction of a C-8 cartridge and a high efficiency ODS column.

    Science.gov (United States)

    Miyagi, Michiko; Yokoyama, Hirokazu; Hibi, Toshifumi

    2007-07-01

    An HPLC protocol for sugar microanalysis based on the formation of ultraviolet-absorbing benzoyl chloride derivatives was improved. Here, samples were prepared with a C-8 cartridge and analyzed with a high efficiency ODS column, in which porous spherical silica particles 3 microm in diameter were packed. These devices allowed us to simultaneously quantify multiple sugars and sugar alcohols up to 10 ng/ml and to provide satisfactory separations of some sugars, such as fructose and myo-inositol and sorbitol and mannitol. This protocol, which does not require special apparatuses, should become a powerful tool in sugar research.

  5. Inductively coupled plasma mass spectrometry study of the retention behavior of arsenic species on various solid phase extraction cartridges and its application in arsenic speciation

    Energy Technology Data Exchange (ETDEWEB)

    Yu Chunhai; Cai Qiantao E-mail: qtcai@cawt.sui.com.sg; Guo Zhongxian; Yang Zhaoguang; Khoo, Soo Beng

    2003-07-18

    Inductively coupled plasma mass spectrometry (ICP-MS) was used to investigate the retention behavior of arsenite, arsenate, monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), arsenocholine (AsC), trimethylarsine oxide (TMAO) and tetramethylarsonium ion (TMAI) on various silica-based solid phase extraction (SPE) cartridges. A method for arsenic speciation is then developed on the basis of selective SPE separation of arsenic species and highly sensitive ICP-MS detection. Factors affecting the retention and elution of arsenic species were examined. Results showed that the retention of arsenic species depended on the chemical characteristics of arsenic species and the types of sorbent materials. Change of pH in the range of 2.0-9.0 did not show significant effects on the retention of DMA, AsB, AsC, TMAI and TMAO on an ethylbenzene sulfonic acid-based strong cation exchange (SCX-3) cartridge. pH also did not influence the retention of AsB, AsC, TMAI and TMAO on a mixed-mode (M-M) cartridge containing non-polar, strong cation exchange and strong anion exchange (SAX) functional groups. However, the retentions of As(V) and MMA on the SAX and the M-M cartridge changed with pH. As(V) and MMA were completely retained on the SAX cartridge and sequentially selectively eluted with 1.0 mol l{sup -1} acetic acid (for MMA). DMA, AsB, AsC, TMAI and TMAO were completely retained on the SCX-3 cartridge and sequentially selectively eluted with 1.0 mol l{sup -1} HNO{sub 3} (for DMA). As(V), MMA, AsB, AsC, TMAI and TMAO were completely retained on the M-M cartridge. As(III) was not retained on either cartridge and remained in solution. Arsenic species in solution and those eluted from the cartridges were subsequently determined by ICP-MS. A detection limit of 8 ng l{sup -1} arsenic in water sample was obtained. This method was successfully applied to arsenic speciation in various sources of water samples (drinking water, waste water, raw water, etc.) and US

  6. Positive detection of exfoliated colon cancer cells on linear stapler cartridges was associated with depth of tumor invasion and preoperative bowel preparation in colon cancer.

    Science.gov (United States)

    Ikehara, Kishiko; Endo, Shungo; Kumamoto, Kensuke; Hidaka, Eiji; Ishida, Fumio; Tanaka, Jun-Ichi; Kudo, Shin-Ei

    2016-08-31

    The aim of this study was to investigate exfoliated cancer cells (ECCs) on linear stapler cartridges used for anastomotic sites in colon cancer. We prospectively analyzed ECCs on linear stapler cartridges used for anastomosis in 100 colon cancer patients who underwent colectomy. Having completed the functional end-to-end anastomosis, the linear stapler cartridges were irrigated with saline, which was collected for cytological examination and cytological diagnoses were made by board-certified pathologists based on Papanicolaou staining. The detection rate of ECCs on the linear stapler cartridges was 20 %. Positive detection of ECCs was significantly associated with depth of tumor invasion (p = 0.012) and preoperative bowel preparation (p = 0.003). There were no marked differences between ECC-positive and ECC-negative groups in terms of the operation methods, tumor location, histopathological classification, and surgical margins. Since ECCs were identified on the cartridge of the linear stapler used for anastomosis, preoperative mechanical bowel preparation using polyethylene glycol solution and cleansing at anastomotic sites using tumoricidal agents before anastomosis may be necessary to decrease ECCs in advanced colon cancer.

  7. Theory of defects in non-metallic solids. Progress report, 1 August 1985-31 July 1986

    International Nuclear Information System (INIS)

    Kunz, A.B.

    1986-07-01

    A general method based on ab initio quantum mechanical modelling and also utilizing semi-classical modelling of a type introduced by Mott-Littleton in 1938 is being implemented to describe the effects of a point defector impurity and/or their interaction in a solid system in a self consistent way. The initial thrust has been to define the scope of the model: in particular, trying to obtain a general model sufficient for describing any point defect of impurity problem in any non-metallic solid system, in the validation of the several concepts necessary for such a model, in the generalization of some necessary theoretical formalism, and finally in a series of initial studies designed to test both the concepts and the validity of the implementation of them. These latter studies include a study of the excitonic spectrum of several alkali halides, the study of a charged neutral defect system in the alkali halides and a study of whether or not these methodologies are capable of predicting the lattice geometries of several of the alkali halides. These studies are significant in several ways. They establish among other things the size of cluster needed for such a study, the utility norm conserving core replacing pseudopotentials, the need for treating relativistic effects including spin orbit, Darwin and mass velocity terms and the necessity of including multiplet structure in an appropriate way for localized excitations

  8. A Fully Nonmetallic Gas Turbine Engine Enabled by Additive Manufacturing, Part II: Additive Manufacturing and Characterization of Polymer Composites

    Science.gov (United States)

    Chuang, Kathy C.; Grady, Joseph E.; Arnold, Steven M.; Draper, Robert D.; Shin, Eugene; Patterson, Clark; Santelle, Tom; Lao, Chao; Rhein, Morgan; Mehl, Jeremy

    2015-01-01

    This publication is the second part of the three part report of the project entitled "A Fully Nonmetallic Gas Turbine Engine Enabled by Additive Manufacturing" funded by NASA Aeronautics Research Institute (NARI). The objective of this project was to conduct additive manufacturing to produce aircraft engine components by Fused Deposition Modeling (FDM), using commercially available polyetherimides-Ultem 9085 and experimental Ultem 1000 mixed with 10% chopped carbon fiber. A property comparison between FDM-printed and injection molded coupons for Ultem 9085, Ultem 1000 resin and the fiber-filled composite Ultem 1000 was carried out. Furthermore, an acoustic liner was printed from Ultem 9085 simulating conventional honeycomb structured liners and tested in a wind tunnel. Composite compressor inlet guide vanes were also printed using fiber-filled Ultem 1000 filaments and tested in a cascade rig. The fiber-filled Ultem 1000 filaments and composite vanes were characterized by scanning electron microscope (SEM) and acid digestion to determine the porosity of FDM-printed articles which ranged from 25 to 31%. Coupons of Ultem 9085, experimental Ultem 1000 composites and XH6050 resin were tested at room temperature and 400F to evaluate their corresponding mechanical properties. A preliminary modeling was also initiated to predict the mechanical properties of FDM-printed Ultem 9085 coupons in relation to varied raster angles and void contents, using the GRC-developed MAC/GMC program.

  9. Separation of Non-metallic Inclusions from a Fe-Al-O Melt Using a Super-Gravity Field

    Science.gov (United States)

    Song, Gaoyang; Song, Bo; Guo, Zhancheng; Yang, Yuhou; Song, Mingming

    2018-02-01

    An innovative method for separating non-metallic inclusions from a high temperature melt using super gravity was systematically investigated. To explore the separation behavior of inclusion particles with densities less than that of metal liquid under a super-gravity field, a Fe-Al-O melt containing Al2O3 particles was treated with different gravity coefficients. Al2O3 particles migrated rapidly towards the reverse direction of the super gravity and gathered in the upper region of the sample. It was hard to find any inclusion particles with sizes greater than 2 μm in the middle and bottom areas. Additionally, the oxygen content in the middle region of the sample could be reduced to 0.0022 mass pct and the maximum removal rate of the oxygen content reached 61.4 pct. The convection in the melt along the direction of the super gravity was not generated by the super-gravity field, and the fluid velocity in the molten melt consisted only of the rotating tangential velocity. Moreover, the motion behavior of the Al2O3 particles was approximatively determined by Stokes' law along the direction of super gravity.

  10. Deformation and fracture properties of metals with non-metallic inclusions; Verformung und Bruch von Metallen mit nichtmetallischen Einschluessen

    Energy Technology Data Exchange (ETDEWEB)

    Schmauder, S.; Soppa, E. [Stuttgart Univ. (Germany). Staatliche Materialpruefungsanstalt

    1998-12-31

    Microstructural effects due to formation of non-uniform lines of non-metallic inclusions in the matrix are examined with respect to their macro-, meso-, and micromechanical effects in the alloy Al(6061) reinforced by SiC inclusions. A comparative analysis of results obtained with various microstructures reveals essential differences in the formation of shear bands, stress peaks, and strain concentrations in the material structure. The maxima and the distribution of those field variables are determined not only by the arrangement of inclusions clusters in the stringers but also depend on the presence and number of single-particle inclusions in pure matrix material. The banding of the microstructure causes a strongly anisotropic behaviour in terms of stress and strain distributions. (orig./CB) [Deutsch] In diesem Beitrag werden Gefuegeeinfluesse aufgrund unterschiedlich starker zeiliger Anordnungen der Teilchen in der Matrix im Hinblick auf ihre makro-, meso- und mikromechanischen Auswirkungen am Beispiel einer SiC-teilchenverstaerkten Aluminiumlegierung Al(6061) untersucht. Ein Vergleich der Ergebnisse verschiedener Gefuege zeigt wesentliche Unterschiede hinsichtlich der Ausbildung von Scherbaendern, Spannungsspitzen und von Dehnungskonzentrationen im Werkstoffgefuege. Die Maxima und die Verteilung dieser Feldgroessen sind nicht nur abhaengig davon, wie die Teilchen in den Zeilen angeordnet sind, sondern auch davon, ob einzelne Teilchen in reinen Matrixbereichen vorhanden sind. Die Zeiligkeit des Gefueges fuehrt zu einem stark anisotropen Verhalten hinsichtlich Spannungs- und Dehnungsverteilungen. (orig.)

  11. Bibliographies on radiation chemistry: Pt. 12; Rate constants for reactions of nonmetallic inorganic radicals in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Helman, W P; Ross, A B [Notre Dame Univ., IN (USA). Radiation Chemistry Data Center

    1990-01-01

    Rate constants have been determined by pulse radiolysis, flash photolysis, and other methods, for a wide variety of reactions involving transient radicals in aqueous solution. Reliable rate constants have been established for reactions of radicals from water (e{sub aq}{sup -}, {center dot}H, {center dot}OH/{center dot}O{sup -}) and the data have been tabulated (Buxton, 1988) through 1986. Kinetic data for HO{sub 2}{center dot}/O{sub 2}{center dot}{sup -} were tabulated. (Bielski, 1985) from papers published through 1983. A compilation of rate constants, from the literature through Mid-1987, for other nonmetallic inorganic radicals has also appeared recently (Neta, 1988). Together, these compilations contain rate constants for more than 6,000 different reactions, reported in about 2,000 references. The present bibliography provides a list of relevant references which have been collected since the publication of the above-mentioned compilations. The list contains references received through the end of December, 1989. (author).

  12. Effect of non-metallic precipitates and grain size on core loss of non-oriented electrical silicon steels

    Science.gov (United States)

    Wang, Jiayi; Ren, Qiang; Luo, Yan; Zhang, Lifeng

    2018-04-01

    In the current study, the number density and size of non-metallic precipitates and the size of grains on the core loss of the 50W800 non-oriented electrical silicon steel sheets were investigated. The number density and size of precipitates and grains were statistically analyzed using an automatic scanning electron microscope (ASPEX) and an optical microscope. Hypothesis models were established to reveal the physical feature for the function of grain size and precipitates on the core loss of the steel. Most precipitates in the steel were AlN particles smaller than 1 μm so that were detrimental to the core loss of the steel. These finer AlN particles distributed on the surface of the steel sheet. The relationship between the number density of precipitates (x in number/mm2 steel area) and the core loss (P1.5/50 in W/kg) was regressed as P1.5/50 = 4.150 + 0.002 x. The average grain size was approximately 25-35 μm. The relationship between the core loss and grain size (d in μm) was P1.5/50 = 3.851 + 20.001 d-1 + 60.000 d-2.

  13. Thermal enhancement cartridge heater modified tritium hydride bed development, Part 2 - Experimental validation of key conceptual design features

    Energy Technology Data Exchange (ETDEWEB)

    Heroux, K.J.; Morgan, G.A. [Savannah River Laboratory, Aiken, SC (United States)

    2015-03-15

    The Thermal Enhancement Cartridge Heater Modified (TECH Mod) tritium hydride bed is an interim replacement for the first generation (Gen1) process hydride beds currently in service in the Savannah River Site (SRS) Tritium Facilities. 3 new features are implemented in the TECH Mod hydride bed prototype: internal electric cartridge heaters, porous divider plates, and copper foam discs. These modifications will enhance bed performance and reduce costs by improving bed activation and installation processes, in-bed accountability measurements, end-of-life bed removal, and He-3 recovery. A full-scale hydride bed test station was constructed at the Savannah River National Laboratory (SRNL) in order to evaluate the performance of the prototype TECH Mod hydride bed. Controlled hydrogen (H{sub 2}) absorption/ desorption experiments were conducted to validate that the conceptual design changes have no adverse effects on the gas transfer kinetics or H{sub 2} storage/release properties compared to those of the Gen1 bed. Inert gas expansions before, during, and after H{sub 2} flow tests were used to monitor changes in gas transfer rates with repeated hydriding/de-hydriding of the hydride material. The gas flow rates significantly decreased after initial hydriding of the material; however, minimal changes were observed after repeated cycling. The data presented herein confirm that the TECH Mod hydride bed would be a suitable replacement for the Gen1 bed with the added enhancements expected from the advanced design features. (authors)

  14. Fast and Easy Drying Method for the Preparation of Activated [{sup 18}F]Fluoride Using Polymer Cartridge

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jai Woong [Inha University, Inchon (Korea, Republic of); Lee, Byoung Se; Chi, Dae Yoon [FutureChem Co., Ltd., Seoul (Korea, Republic of); Lee, Sang Ju [Sogang University, Seoul (Korea, Republic of); Oh, Seung Jun [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2011-01-15

    An efficient nucleophilic [{sup 18}F]fluorination has been studied to reduce byproducts and preparation time. Instead of conventional aqueous solution of K{sub 2}CO{sub 3}-K{sub 222}, several organic solution containing inert organic salts were used to release [{sup 18}F]fluoride ion and anion bases captured in the polymer cartridge, concluding that methanol solution is the best choice. Comparing to azeotropic drying process, one min was sufficient to remove methanol completely, resulting in about 10% radioactivity saving by reducing drying time. The polymer cartridge, Chromafix (PS-HCO{sub 3}) was pretreated with several anion bases to displace pre-loaded bicarbonate base. Phosphate bases showed better results than carbonate bases in terms of lower basicity. tert-Butanol solvent used as a reaction media played another critical role in nucleophilic [{sup 18}F]fluorination by suppressing eliminated side product. Consequent [{sup 18}F]fluorination under the present condition afforded fast preparation of reaction solution and high radiochemical yields (98% radio-TLC, 84% RCY) with 94% of precursor remained.

  15. Development of a method for rapid and simultaneous monitoring of particulate and dissolved radiocesium in water with nonwoven fabric cartridge filters

    International Nuclear Information System (INIS)

    Hideki Tsuji; Tetsuo Yasutaka; Yoshihiko Kondo; Yasukazu Suzuki

    2014-01-01

    A method for the rapid and simultaneous monitoring of particulate and dissolved 137 Cs concentration in water was developed. This method uses pleated polypropylene nonwoven fabric filter to collect particulate radiocesium, and nonwoven fabric impregnated with Prussian blue (PB) to absorb dissolved radiocesium. The fabric was placed into cylindrical plastic cartridges (SS-cartridge and PB-cartridge). Traditional monitoring methods, such as evaporative concentration, often require time for pre-processing. However, this method described requires much less pre-processing time before the detection. Experiments conducted with simulated river water demonstrated that almost all of the suspended solids weight was collected in the SS-cartridge, and that more than 92 % of dissolved 137 Cs was absorbed onto the two PB-cartridges by 2.5 L/min flow rate when the range of the pH was 6-8. This device was applied to monitor Abukuma River water at two locations and the results were compared with those obtained using the filtrating and evaporative concentration method. The suspended solids concentration in river water, calculated by weight gain of the SS-cartridge and by sediment weight after filtration with a 0.45-μm membrane filter, agreed well. The radioactivity of the particulate and dissolved 137 Cs also agreed well in one of the two replications of this method. In addition, the required time for pre-processing was reduced by 60 times that by filtrating and evaporative concentration method. This method can separately collect and concentrate particulate and dissolved radiocesium rapidly and simultaneously in the field. (author)

  16. Separation of V(V)-4-(2-pyridylazo)resorcinolato complex from a large excess reagent using an ODS cartridge for high-performance liquid chromatography.

    Science.gov (United States)

    Takahashi, Toru; Kaneko, Emiko; Yotsuyanagi, Takao

    2006-12-01

    A selective off-line preconcentration technique for the V(V) complex with 4-(2-pyridylazo)resorcinol has been developed and successfully applied to the determination of V(V) in an air-borne sample. The target complex was separated from excess reagent using an ODS cartridge and water as the eluent. The complex was then concentrated on another ODS cartridge using tetrabutylammonium bromide and eluted with methanol; the eluate was applied to a one-drop concentration/HPLC. A detection limit as low as (6.05 +/- 0.82)x 10(-11) M (5 ppt) was achieved.

  17. Energy consumption analysis of Spanish food and drink, textile, chemical and non-metallic mineral products sectors

    International Nuclear Information System (INIS)

    Aranda-Usón, Alfonso; Ferreira, Germán; Mainar-Toledo, M.D.; Scarpellini, Sabina; Llera Sastresa, Eva

    2012-01-01

    This paper provides quantitative information for energy consumption from four different industry sectors based on an energy analysis obtained by means of in-situ energy audits and complementary information. The latter information was taken from Saving Strategy and Energy Efficiency in Spain (Estrategia de Ahorro y Eficiencia Energética en España 2004–2010, E4) documents and the 2009 Industrial Survey of Spain from the National Statistics Institute (Instituto Nacional de Estadística, INE). The results show an estimate of energy consumption for each sector, namely Spanish food, drink and tobacco (9.6%), textile (4.5%), chemical (14.7%), and non-metallic mineral products (24.3%), as well as the degree of inefficiency for each, obtained by means of a stochastic frontier production function model. These results are combined with the energy consumption analysis to identify potential energy saving opportunities around 20.0% of the total energy consumption for all studied sectors. These energy saving opportunities are classified according to thermal or electrical energy consumption and percentage savings of the total energy consumption. -- Highlights: ► This study presents the analysis of four Spanish energy-consuming industrial sectors. ► The four selected sectors account for 33.0% of the total industrial SMEs. ► An audit was carried out in several factories from each analysed industrial sector. ► Stochastic Cobb-Douglas frontiers were used to estimate production frontiers. ► Potential energy saving opportunities around 20.0% of the total energy consumption.

  18. A Study on the Nonmetallic Inclusion Motions in a Swirling Flow Submerged Entry Nozzle in a New Cylindrical Tundish Design

    Science.gov (United States)

    Ni, Peiyuan; Ersson, Mikael; Jonsson, Lage Tord Ingemar; Jönsson, Pär Göran

    2018-04-01

    Different sizes and shapes of nonmetallic inclusions in a swirling flow submerged entry nozzle (SEN) placed in a new tundish design were investigated by using a Lagrangian particle tracking scheme. The results show that inclusions in the current cylindrical tundish have difficulties remaining in the top tundish region, since a strong rotational steel flow exists in this region. This high rotational flow of 0.7 m/s provides the required momentum for the formation of a strong swirling flow inside the SEN. The results show that inclusions larger than 40 µm were found to deposit to a smaller extent on the SEN wall compared to smaller inclusions. The reason is that these large inclusions have Separation number values larger than 1. Thus, the swirling flow causes these large size inclusions to move toward the SEN center. For the nonspherical inclusions, large size inclusions were found to be deposited on the SEN wall to a larger extent, compared to spherical inclusions. More specifically, the difference of the deposited inclusion number is around 27 pct. Overall, it was found that the swirling flow contains three regions, namely, the isotropic core region, the anisotropic turbulence region and the near-wall region. Therefore, anisotropic turbulent fluctuations should be taken into account when the inclusion motion was tracked in this complex flow. In addition, many inclusions were found to deposit at the SEN inlet region. The plotted velocity distribution shows that the inlet flow is very chaotic. A high turbulent kinetic energy value of around 0.08 m2/s2 exists in this region, and a recirculating flow was also found here. These flow characteristics are harmful since they increase the inclusion transport toward the wall. Therefore, a new design of the SEN inlet should be developed in the future, with the aim to modify the inlet flow so that the inclusion deposition is reduced.

  19. Construction of a mutagenesis cartridge for poliovirus genome-linked viral protein: isolation and characterization of viable and nonviable mutants

    International Nuclear Information System (INIS)

    Kuhn, R.J.; Tada, H.; Ypma-Wong, M.F.; Dunn, J.J.; Semler, B.L.; Wimmer, E.

    1988-01-01

    By following a strategy of genetic analysis of poliovirus, the authors have constructed a synthetic mutagenesis cartridge spanning the genome-linked viral protein coding region and flanking cleavage sites in an infectious cDNA clone of the type I (Mahoney) genome. The insertion of new restriction sites within the infectious clone has allowed them to replace the wild-type sequences with short complementary pairs of synthetic oligonucleotides containing various mutations. A set of mutations have been made that create methionine codons within the genome-linked viral protein region. The resulting viruses have growth characteristics similar to wild type. Experiments that led to an alteration of the tyrosine residue responsible for the linkage to RNA have resulted in nonviable virus. In one mutant, proteolytic processing assayed in vitro appeared unimpaired by the mutation. They suggest that the position of the tyrosine residue is important for genome-linked viral protein function(s)

  20. [Effectiveness of FTA Elute® indicating cartridge in combination with hybrid capture 2 for cervical cancer screening].

    Science.gov (United States)

    Chen, Feng; Zhang, Xi; Wang, Shaoming; Hu, Shangying; Chen, Wen; Zhao, Fanghui; He, Wei; Zhang, Yuqing; Qiao, Youlin

    2015-02-01

    To evaluate the effectiveness of FTA Elute® Cartridge (GE healthcare, Kent, UK) in combination with hybrid capture 2 (HC2) testing for cervical cancer screening. From May to June 2012, 412 women aged 25 to 65 years in Jiangxi Tonggu were enrolled in the study. We used pathological outcome as the gold standard, and the accuracy of the FTA card in combination with HC2 testing was investigated from both physician- and self-sampling, respectively. Physician sampling using the FTA card in combination with HC2 testing showed a comparable sensitivity (12/13) with the liquid based medium, but a higher specificity 69.5% (266/383) vs (77.8%, 298/383) (P FTA card in combination with HC2 testing with liquid based medium was 10/13 vs 8/13(P = 0.625) and (62.3%, 238/382) vs (75.7%, 289/382) (P FTA and liquid-based sampling medium was 86.1% (340/395) and 79.5% (314/395). For physician-collected samples used for HC2 testing to detect CIN2+, the accuracy of the FTA card was superior to that of the liquid-based medium (area under the receiver operating characteristic curve (AUC) = 0.898, 95%CI:0.838-0.958). FTA Elute® cartridge in combination with HC2 testing is a promising method of specimen transport for cervical cancer screening programs with a good precision.With further optimization, it could become an effective method for cervical cancer screening in various economic levels of areas.

  1. Preparation of a New Adsorbent from Activated Carbon and Carbon Nanofiber (AC/CNF for Manufacturing Organic-Vacbpour Respirator Cartridge

    Directory of Open Access Journals (Sweden)

    Mehdi Jahangiri

    2013-01-01

    Full Text Available In this study a composite of activated carbon and carbon nanofiber (AC/CNF was prepared to improve the performance of activated carbon (AC for adsorption of volatile organic compounds (VOCs and its utilization for respirator cartridges. Activated carbon was impregnated with a nickel nitrate catalyst precursor and carbonnanofibers (CNF were deposited directly on the AC surface using catalytic chemical vapor deposition. Deposited CNFs on catalyst particles in AC micropores, were activated by CO2 to recover the surface area and micropores.Surface and textural characterizations of the prepared composites were investigated using Brunauer, Emmett andTeller’s (BET technique and electron microscopy respectively. Prepared composite adsorbent was tested forbenzene, toluene and xylene (BTX adsorption and then employed in an organic respirator cartridge in granularform. Adsorption studies were conducted by passing air samples through the adsorbents in a glass column at an adjustable flow rate. Finally, any adsorbed species not retained by the adsorbents in the column were trapped in a charcoal sorbent tube and analyzed by gas chromatography. CNFs with a very thin diameter of about 10-20 nmwere formed uniformly on the AC/CNF. The breakthrough time for cartridges prepared with CO2 activated AC/CNF was 117 minutes which are significantly longer than for those cartridges prepared with walnut shell- based activated carbon with the same weight of adsorbents. This study showed that a granular form CO2 activated AC/CNF composite could be a very effective alternate adsorbent for respirator cartridges due to its larger adsorption capacities and lower weight.

  2. Time since discharge of 9mm cartridges by headspace analysis, part 1: Comprehensive optimisation and validation of a headspace sorptive extraction (HSSE) method.

    Science.gov (United States)

    Gallidabino, M; Romolo, F S; Weyermann, C

    2017-03-01

    Estimating the time since discharge of spent cartridges can be a valuable tool in the forensic investigation of firearm-related crimes. To reach this aim, it was previously proposed that the decrease of volatile organic compounds released during discharge is monitored over time using non-destructive headspace extraction techniques. While promising results were obtained for large-calibre cartridges (e.g., shotgun shells), handgun calibres yielded unsatisfying results. In addition to the natural complexity of the specimen itself, these can also be attributed to some selective choices in the methods development. Thus, the present series of paper aimed to more systematically evaluate the potential of headspace analysis to estimate the time since discharge of cartridges through the use of more comprehensive analytical and interpretative techniques. Specifically, in this first part, a method based on headspace sorptive extraction (HSSE) was comprehensively optimised and validated, as the latter recently proved to be a more efficient alternative than previous approaches. For this purpose, 29 volatile organic compounds were preliminary selected on the basis of previous works. A multivariate statistical approach based on design of experiments (DOE) was used to optimise variables potentially involved in interaction effects. Introduction of deuterated analogues in sampling vials was also investigated as strategy to account for analytical variations. Analysis was carried out by selected ion mode, gas chromatography coupled to mass spectrometry (GC-MS). Results showed good chromatographic resolution as well as detection limits and peak area repeatability. Application to 9mm spent cartridges confirmed that the use of co-extracted internal standards allowed for improved reproducibility of the measured signals. The validated method will be applied in the second part of this work to estimate the time since discharge of 9mm spent cartridges using multivariate models. Copyright

  3. High laboratory cost predicted per tuberculosis case diagnosed with increased case finding without a triage strategy.

    Science.gov (United States)

    Dunbar, R; Naidoo, P; Beyers, N; Langley, I

    2017-09-01

    Cape Town, South Africa. To model the effects of increased case finding and triage strategies on laboratory costs per tuberculosis (TB) case diagnosed. We used a validated operational model and published laboratory cost data. We modelled the effect of varying the proportion with TB among presumptive cases and Xpert cartridge price reductions on cost per TB case and per additional TB case diagnosed in the Xpert-based vs. smear/culture-based algorithms. In our current scenario (18.3% with TB among presumptive cases), the proportion of cases diagnosed increased by 8.7% (16.7% vs. 15.0%), and the cost per case diagnosed increased by 142% (US$121 vs. US$50). The cost per additional case diagnosed was US$986. This would increase to US$1619 if the proportion with TB among presumptive cases was 10.6%. At 25.9-30.8% of TB prevalence among presumptive cases and a 50% reduction in Xpert cartridge price, the cost per TB case diagnosed would range from US$50 to US$59 (comparable to the US$48.77 found in routine practice with smear/culture). The operational model illustrates the effect of increased case finding on laboratory costs per TB case diagnosed. Unless triage strategies are identified, the approach will not be sustainable, even if Xpert cartridge prices are reduced.

  4. The Effect of Cooling Conditions on the Evolution of Non-metallic Inclusions in High Manganese TWIP Steels

    Science.gov (United States)

    Wang, Yu-Nan; Yang, Jian; Xin, Xiu-Ling; Wang, Rui-Zhi; Xu, Long-Yun

    2016-04-01

    In the present study, the effect of cooling conditions on the evolution of non-metallic inclusions in high manganese TWIP steels was investigated based on experiments and thermodynamic calculations. In addition, the formation and growth behavior of AlN inclusions during solidification under different cooling conditions were analyzed with the help of thermodynamics and dynamics. The inclusions formed in the high manganese TWIP steels are classified into nine types: (1) AlN; (2) MgO; (3) CaS; (4) MgAl2O4; (5) AlN + MgO; (6) MgO + MgS; (7) MgO + MgS + CaS; (8) MgO + CaS; (9) MgAl2O4 + MgS. With the increase in the cooling rate, the volume fraction and area ratio of inclusions are almost constant; the size of inclusions decreases and the number density of inclusions increases in the steels. The thermodynamic results of inclusion types calculated with FactSage are consistent with the observed results. With increasing cooling rate, the diameter of AlN decreases. When the cooling rate increases from 0.75 to 4.83 K s-1, the measured average diameter of AlN decreases from 4.49 to 2.42 μm. Under the high cooling rate of 4.83 K s-1, the calculated diameter of AlN reaches 3.59 μm at the end of solidification. However, the calculated diameter of AlN increases to approximately 5.93 μm at the end of solidification under the low cooling rate of 0.75 K s-1. The calculated diameter of AlN decreases with increasing cooling rate. The theoretical calculation results of the change in diameter of AlN under the different cooling rates have the same trend with the observed results. The existences of inclusions in the steels, especially AlN which average sizes are 2.42 and 4.49 μm, respectively, are not considered to have obvious influences on the hot ductility.

  5. Corrosion behaviour of metallic and non-metallic materials in various media in the Anhydrite and Gypsum Mine Felsenau/AG

    International Nuclear Information System (INIS)

    Laske, D.; Wiedemann, K.H.

    1983-10-01

    The final underground disposal of radioactive wastes necessitates container materials with a good long-term resistance against corrosion from both external agents and the solidification matrix inside. For low- and medium-level active waste, repositories in anhydrite sites, among others, are under consideration. Sheet and plate samples from 14 metallic and 8 non-metallic materials have been tested for 5 years in a tunnel in the Anhydrite and Gypsum Mine Felsenau/AG for their corrosion resistance in the tunnel atmosphere, anhydrite powder, gypsum powder, gypsum, and cement. From the metallic materials tested, only chromium-nickel steel is corrosion resistant to all the media present. Zinc plated and tin plated iron sheet as well as aluminium and aluminium alloys are corrosion resistant only in the atmosphere of the tunnel, and lead plated iron sheet is resistant also in cement. Aluminium is dissolved in cement. Uncovered iron sheet undergoes severe corrosion. The non-metallic coatings tested (lacquer, stove lacquer, or synthetic resins) partially flake off already after one year's testing and are therefore not appropriate for iron sheet corrosion protection. No influence of the different media has been observed after 5 years on the 8 plastic materials tested (6 without, and 2 with glass fiber reinforcement). (author)

  6. A Fully Non-Metallic Gas Turbine Engine Enabled by Additive Manufacturing Part I: System Analysis, Component Identification, Additive Manufacturing, and Testing of Polymer Composites

    Science.gov (United States)

    Grady, Joseph E.; Haller, William J.; Poinsatte, Philip E.; Halbig, Michael C.; Schnulo, Sydney L.; Singh, Mrityunjay; Weir, Don; Wali, Natalie; Vinup, Michael; Jones, Michael G.; hide

    2015-01-01

    The research and development activities reported in this publication were carried out under NASA Aeronautics Research Institute (NARI) funded project entitled "A Fully Nonmetallic Gas Turbine Engine Enabled by Additive Manufacturing." The objective of the project was to conduct evaluation of emerging materials and manufacturing technologies that will enable fully nonmetallic gas turbine engines. The results of the activities are described in three part report. The first part of the report contains the data and analysis of engine system trade studies, which were carried out to estimate reduction in engine emissions and fuel burn enabled due to advanced materials and manufacturing processes. A number of key engine components were identified in which advanced materials and additive manufacturing processes would provide the most significant benefits to engine operation. The technical scope of activities included an assessment of the feasibility of using additive manufacturing technologies to fabricate gas turbine engine components from polymer and ceramic matrix composites, which were accomplished by fabricating prototype engine components and testing them in simulated engine operating conditions. The manufacturing process parameters were developed and optimized for polymer and ceramic composites (described in detail in the second and third part of the report). A number of prototype components (inlet guide vane (IGV), acoustic liners, engine access door) were additively manufactured using high temperature polymer materials. Ceramic matrix composite components included turbine nozzle components. In addition, IGVs and acoustic liners were tested in simulated engine conditions in test rigs. The test results are reported and discussed in detail.

  7. Strength and deformability of compressed concrete elements with various types of non-metallic fiber and rods reinforcement under static loading

    Science.gov (United States)

    Nevskii, A. V.; Baldin, I. V.; Kudyakov, K. L.

    2015-01-01

    Adoption of modern building materials based on non-metallic fibers and their application in concrete structures represent one of the important issues in construction industry. This paper presents results of investigation of several types of raw materials selected: basalt fiber, carbon fiber and composite fiber rods based on glass and carbon. Preliminary testing has shown the possibility of raw materials to be effectively used in compressed concrete elements. Experimental program to define strength and deformability of compressed concrete elements with non-metallic fiber reinforcement and rod composite reinforcement included design, manufacture and testing of several types of concrete samples with different types of fiber and longitudinal rod reinforcement. The samples were tested under compressive static load. The results demonstrated that fiber reinforcement of concrete allows increasing carrying capacity of compressed concrete elements and reducing their deformability. Using composite longitudinal reinforcement instead of steel longitudinal reinforcement in compressed concrete elements insignificantly influences bearing capacity. Combined use of composite rod reinforcement and fiber reinforcement in compressed concrete elements enables to achieve maximum strength and minimum deformability.

  8. Randomized Comparison of Two Vaginal Self-Sampling Methods for Human Papillomavirus Detection: Dry Swab versus FTA Cartridge.

    Science.gov (United States)

    Catarino, Rosa; Vassilakos, Pierre; Bilancioni, Aline; Vanden Eynde, Mathieu; Meyer-Hamme, Ulrike; Menoud, Pierre-Alain; Guerry, Frédéric; Petignat, Patrick

    2015-01-01

    Human papillomavirus (HPV) self-sampling (self-HPV) is valuable in cervical cancer screening. HPV testing is usually performed on physician-collected cervical smears stored in liquid-based medium. Dry filters and swabs are an alternative. We evaluated the adequacy of self-HPV using two dry storage and transport devices, the FTA cartridge and swab. A total of 130 women performed two consecutive self-HPV samples. Randomization determined which of the two tests was performed first: self-HPV using dry swabs (s-DRY) or vaginal specimen collection using a cytobrush applied to an FTA cartridge (s-FTA). After self-HPV, a physician collected a cervical sample using liquid-based medium (Dr-WET). HPV types were identified by real-time PCR. Agreement between collection methods was measured using the kappa statistic. HPV prevalence for high-risk types was 62.3% (95%CI: 53.7-70.2) detected by s-DRY, 56.2% (95%CI: 47.6-64.4) by Dr-WET, and 54.6% (95%CI: 46.1-62.9) by s-FTA. There was overall agreement of 70.8% between s-FTA and s-DRY samples (kappa = 0.34), and of 82.3% between self-HPV and Dr-WET samples (kappa = 0.56). Detection sensitivities for low-grade squamous intraepithelial lesion or worse (LSIL+) were: 64.0% (95%CI: 44.5-79.8) for s-FTA, 84.6% (95%CI: 66.5-93.9) for s-DRY, and 76.9% (95%CI: 58.0-89.0) for Dr-WET. The preferred self-collection method among patients was s-DRY (40.8% vs. 15.4%). Regarding costs, FTA card was five times more expensive than the swab (~5 US dollars (USD)/per card vs. ~1 USD/per swab). Self-HPV using dry swabs is sensitive for detecting LSIL+ and less expensive than s-FTA. International Standard Randomized Controlled Trial Number (ISRCTN): 43310942.

  9. Randomized Comparison of Two Vaginal Self-Sampling Methods for Human Papillomavirus Detection: Dry Swab versus FTA Cartridge.

    Directory of Open Access Journals (Sweden)

    Rosa Catarino

    Full Text Available Human papillomavirus (HPV self-sampling (self-HPV is valuable in cervical cancer screening. HPV testing is usually performed on physician-collected cervical smears stored in liquid-based medium. Dry filters and swabs are an alternative. We evaluated the adequacy of self-HPV using two dry storage and transport devices, the FTA cartridge and swab.A total of 130 women performed two consecutive self-HPV samples. Randomization determined which of the two tests was performed first: self-HPV using dry swabs (s-DRY or vaginal specimen collection using a cytobrush applied to an FTA cartridge (s-FTA. After self-HPV, a physician collected a cervical sample using liquid-based medium (Dr-WET. HPV types were identified by real-time PCR. Agreement between collection methods was measured using the kappa statistic.HPV prevalence for high-risk types was 62.3% (95%CI: 53.7-70.2 detected by s-DRY, 56.2% (95%CI: 47.6-64.4 by Dr-WET, and 54.6% (95%CI: 46.1-62.9 by s-FTA. There was overall agreement of 70.8% between s-FTA and s-DRY samples (kappa = 0.34, and of 82.3% between self-HPV and Dr-WET samples (kappa = 0.56. Detection sensitivities for low-grade squamous intraepithelial lesion or worse (LSIL+ were: 64.0% (95%CI: 44.5-79.8 for s-FTA, 84.6% (95%CI: 66.5-93.9 for s-DRY, and 76.9% (95%CI: 58.0-89.0 for Dr-WET. The preferred self-collection method among patients was s-DRY (40.8% vs. 15.4%. Regarding costs, FTA card was five times more expensive than the swab (~5 US dollars (USD/per card vs. ~1 USD/per swab.Self-HPV using dry swabs is sensitive for detecting LSIL+ and less expensive than s-FTA.International Standard Randomized Controlled Trial Number (ISRCTN: 43310942.

  10. Improvements of the sensitivity of burst cartridge detection; Amelioration du seuil de detection des ruptures de gaine

    Energy Technology Data Exchange (ETDEWEB)

    Vasnier, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    I - Special tests for improving the sensitivity of burst cartridge detection equipment in power reactors II - Scintillator purge-flow tests using aged gas in the B.C.D. /E.D.F. 2 Summary. - The first part of this report describes the tests carried out on fission product detectors by a process in which gas is continuously injected in front of the scintillator. Using this system, the background is reduced and perturbations caused by pneumatic switches on the prospecting circuits are eliminated. The quality of the signals thus obtained permits better processing of the data and thus leads to a possible improvement in the sensitivity of burst cartridge detection. The second part gives results of tests carried out with both fresh and aged gases, the economic advantage of the latter being that it permits recycling through the reactor. Reduction of the background is less pronounced but the advantage of the stable signals is conserved. (author) [French] I - Essais speciaux pour ameliorer le seuil de detection des installations de D.R.G. des reacteurs de puissance II- Essais de balayage sous scintillateur avec gaz vieilli a la D.R.G. /E.D.F. 2 Sommaire. - La premiere partie de ce rapport decrit les essais effectues sur les detecteurs de produits de fission par un procede d'injection continue de gaz sous le scintillateur. Grace a ce systeme on obtient une reduction du bruit de fond et l'elimination des perturbations causees par les commutations pneumatiques des circuits de prospection. La qualite des signaux obtenus ainsi permet un meilleur traitement des informations d'ou une amelioration possible du seuil de detection des ruptures de gaines. La seconde partie donne les resultats d'essais effectues avec du gaz propre et vieilli, l'utilisation de ce dernier presentant l'avantage economique d'etre recycle du reacteur. La reduction du bruit de fond est moins importante mais on conserve l'avantage de la stabilisation des signaux. (auteur)

  11. Lyophilization Cycle Design for Dual Chamber Cartridges and a Method for Online Process Control: The "DCC LyoMate" Procedure.

    Science.gov (United States)

    Korpus, Christoph; Friess, Wolfgang

    2017-08-01

    Freeze-drying process design is a challenging task that necessitates a profound understanding of the complex interrelation among critical process parameters (e.g., shelf temperature and chamber pressure), heat transfer characteristics of the involved materials (e.g., product containers and holder devices), and critical quality attributes of the product (e.g., collapse temperatures). The Dual Chamber Cartridge "(DCC) LyoMate" (from lyophilization and automated) is a manometric temperature measurement-based process control strategy that was developed within this study to streamline this complicated task. It was successfully applied using 5% sucrose formulations with 0.5 and 1 mL fill volumes. The system was further challenged using 2, 20, and 100 mg/mL monoclonal antibody formulations. The DCC LyoMate method did not only produce pharmaceutically acceptable cakes but was also able to maintain the desired product temperature irrespective of formulation and protein content. It enabled successful process design even at high protein concentrations and aided the design and online control of the lyophilization process for drying in DCCs within a single development run. Thus, it helps to reduce development cost and the DCC LyoMate can also be easily installed on every freeze-dryer capable of performing a manometric temperature measurement, without the need for hardware modification. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  12. Comparison between a commercial solid-phase extraction cartridge and a home-made silver containing charcoal column: purification of Mo-99 from I-131 and Te-121

    International Nuclear Information System (INIS)

    Dias, Carla Roberta; Teodoro, Rodrigo; Osso Junior, Joao

    2011-01-01

    Among the radioisotopes used for medical application in Nuclear Medicine, 99m Tc, readily available from the elution of 99 Mo/ 99m Tc generators, is the most used, responsible for more than eighty percent of the total applications. These generators use the 99 Mo radioisotope that is produced in nuclear reactors and IPEN imports all the 99 Mo used in Brazil, mainly from Canada (Nordion). Due to the increasing needs of the Nuclear Medicine in Brazil and the world shortage of 99 Mo observed since 2008, IPEN decided to construct a new research reactor named Brazilian Multipurpose Reactor (BMR) as well as to develop the production of 99 Mo through the route of 235 U fission using a CINTICHEM modified separation process. The 99 Mo obtained from this process contains some contaminants and need to be purified. The aim of this work is to compare the preliminary results of the purification step of the solution containing 99 Mo and the contaminants, 131 I and 121 Te in the silver containing charcoal column and a solid-phase extraction cartridge. The purification process of 99 Mo coming from fission LEU foils was performed by adsorption chromatography using a home-made activated charcoal containing silver column (AC-Ag) and a commercial solid-phase extraction cartridge (OnGuard II Ag). High yields of 99 Mo elution and high retention of 131 I were achieved in the AC-Ag column and silver cartridge but 121 Te was more retained in the cartridge than in the AC-Ag column. (author)

  13. Thermal spin filtering effect and giant magnetoresistance of half-metallic graphene nanoribbon co-doped with non-metallic Nitrogen and Boron

    Science.gov (United States)

    Huang, Hai; Zheng, Anmin; Gao, Guoying; Yao, Kailun

    2018-03-01

    Ab initio calculations based on density functional theory and non-equilibrium Green's function are performed to investigate the thermal spin transport properties of single-hydrogen-saturated zigzag graphene nanoribbon co-doped with non-metallic Nitrogen and Boron in parallel and anti-parallel spin configurations. The results show that the doped graphene nanoribbon is a full half-metal. The two-probe system based on the doped graphene nanoribbon exhibits various excellent spin transport properties, including the spin-filtering effect, the spin Seebeck effect, the single-spin negative differential thermal resistance effect and the sign-reversible giant magnetoresistance feature. Excellently, the spin-filtering efficiency can reach nearly 100% in the parallel configuration and the magnetoresistance ratio can be up to -1.5 × 1010% by modulating the electrode temperature and temperature gradient. Our findings indicate that the metal-free doped graphene nanoribbon would be a promising candidate for spin caloritronic applications.

  14. Proteoglycan from salmon nasal cartridge promotes in vitro wound healing of fibroblast monolayers via the CD44 receptor

    International Nuclear Information System (INIS)

    Ito, Gen; Kobayashi, Takeshi; Takeda, Yoshie; Sokabe, Masahiro

    2015-01-01

    Highlights: • Proteoglycan from salmon nasal cartridge (SNC-PG) promoted wound healing in fibroblast monolayers. • SNC-PG stimulated both cell proliferation and cell migration. • Interaction between chondroitin sulfate-units and CD44 is responsible for the effect. - Abstract: Proteoglycans (PGs) are involved in various cellular functions including cell growth, adhesion, and differentiation; however, their physiological roles are not fully understood. In this study, we examined the effect of PG purified from salmon nasal cartilage (SNC-PG) on wound closure using tissue-cultured cell monolayers, an in vitro wound-healing assay. The results indicated that SNC-PG significantly promoted wound closure in NIH/3T3 cell monolayers by stimulating both cell proliferation and cell migration. SNC-PG was effective in concentrations from 0.1 to 10 μg/ml, but showed much less effect at higher concentrations (100–1000 μg/ml). The effect of SNC-PG was abolished by chondroitinase ABC, indicating that chondroitin sulfates (CSs), a major component of glycosaminoglycans (GAGs) in SNC-PG, are crucial for the SNC-PG effect. Furthermore, chondroitin 6-sulfate (C-6-S), a major CS of SNC-PG GAGs, could partially reproduce the SNC-PG effect and partially inhibit the binding of SNC-PG to cells, suggesting that SNC-PG exerts its effect through an interaction between the GAGs in SNC-PG and the cell surface. Neutralization by anti-CD44 antibodies or CD44 knockdown abolished SNC-PG binding to the cells and the SNC-PG effect on wound closure. These results suggest that interactions between CS-rich GAG-chains of SNC-PG and CD44 on the cell surface are responsible for the SNC-PG effect on wound closure

  15. Proteoglycan from salmon nasal cartridge promotes in vitro wound healing of fibroblast monolayers via the CD44 receptor

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Gen; Kobayashi, Takeshi; Takeda, Yoshie [Department of Physiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi 466-8550 (Japan); Sokabe, Masahiro, E-mail: msokabe@med.nagoya-u.ac.jp [Department of Physiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi 466-8550 (Japan); Mechanobiology Laboratory, Nagoya University Graduate School of Medicine, Nagoya, Aichi 466-8550 (Japan); Mechanobiology Institute Singapore, National University of Singapore, Singapore 117411 (Singapore)

    2015-01-16

    Highlights: • Proteoglycan from salmon nasal cartridge (SNC-PG) promoted wound healing in fibroblast monolayers. • SNC-PG stimulated both cell proliferation and cell migration. • Interaction between chondroitin sulfate-units and CD44 is responsible for the effect. - Abstract: Proteoglycans (PGs) are involved in various cellular functions including cell growth, adhesion, and differentiation; however, their physiological roles are not fully understood. In this study, we examined the effect of PG purified from salmon nasal cartilage (SNC-PG) on wound closure using tissue-cultured cell monolayers, an in vitro wound-healing assay. The results indicated that SNC-PG significantly promoted wound closure in NIH/3T3 cell monolayers by stimulating both cell proliferation and cell migration. SNC-PG was effective in concentrations from 0.1 to 10 μg/ml, but showed much less effect at higher concentrations (100–1000 μg/ml). The effect of SNC-PG was abolished by chondroitinase ABC, indicating that chondroitin sulfates (CSs), a major component of glycosaminoglycans (GAGs) in SNC-PG, are crucial for the SNC-PG effect. Furthermore, chondroitin 6-sulfate (C-6-S), a major CS of SNC-PG GAGs, could partially reproduce the SNC-PG effect and partially inhibit the binding of SNC-PG to cells, suggesting that SNC-PG exerts its effect through an interaction between the GAGs in SNC-PG and the cell surface. Neutralization by anti-CD44 antibodies or CD44 knockdown abolished SNC-PG binding to the cells and the SNC-PG effect on wound closure. These results suggest that interactions between CS-rich GAG-chains of SNC-PG and CD44 on the cell surface are responsible for the SNC-PG effect on wound closure.

  16. Type-specific detection of high-risk human papillomavirus (HPV) in self-sampled cervicovaginal cells applied to FTA elute cartridge.

    Science.gov (United States)

    Gustavsson, Inger; Sanner, Karin; Lindell, Monica; Strand, Anders; Olovsson, Matts; Wikström, Ingrid; Wilander, Erik; Gyllensten, Ulf

    2011-08-01

    Most procedures for self-sampling of cervical cells are based on liquid-based media for transportation and storage. An alternative is to use a solid support, such as dry filter paper media. To evaluate if self-sampling of cervicovaginal fluid using a cytobrush (Viba-brush; Rovers Medical Devices B.V., Oss, The Netherlands) and a solid support such as the Whatman Indicating FTA Elute cartridge (GE Healthcare, United Kingdom) can be used for reliable typing of human papillomavirus (HPV), as compared to cervical samples obtained by a physician using a cytobrush and the indicating FTA Elute Micro card and biopsy analysis. A total of 50 women with a previous high-risk (HR) HPV positive test were invited to perform self-sampling using the Viba-brush and the FTA cartridge and thereafter a physician obtained a cervical sample using the cytobrush and a FTA card, together with a cervical biopsy for histology and HPV typing. Detection of HR-HPV types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58 and 59 was performed using three multiplex real-time polymerase chain reaction (PCR) assays. All samples contained sufficient amounts of genomic DNA and the self-samples yielded on average 3.5 times more DNA than those obtained by the physician. All women that were positive for HR-HPV in the biopsy sample also typed positive both by self-sampling and physician-obtained sampling. For women with a histological diagnosis of cervical intraepithelial neoplasia grades 2-3 (CIN 2-3) all three HPV samples showed 100% concordance. A higher number of women were HPV positive by self-sampling than by physician-obtained sampling or by biopsy analysis. The Viba-brush and the FTA cartridge are suitable for self-sampling of vaginal cells and subsequent HR-HPV typing. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Comparison of the Usefulness of SPE Cartridges for the Determination of β-Blockers and β-Agonists (Basic Drugs in Environmental Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Magda Caban

    2015-01-01

    Full Text Available Even though the methodology used for the determination of β-blockers and β-agonists in environmental samples is based mainly on solid-phase extraction (SPE and gas chromatography or liquid chromatography with mass spectrometric detection, the available literature data on the applied SPE procedures is rather sparse. In this paper such comparison is presented. Moreover, the usefulness of the eight SPE cartridges for the determination of five β-blockers (acebutolol, atenolol, metoprolol, nadolol, and propranolol and two β-agonists (salbutamol and terbutaline in environmental aqueous samples using GC techniques is tested. Among them, three (the trifunction sorbent Strata Screen C, the copolymers LiChrolut EN, and the functionalized copolymer Isolute ENV+ were used for the first time for this purpose. It was confirmed that polystyrene-divinylbenzene-N-vinylpyrrolidone copolymers (PS-DVB-VP, Strata-X, and Oasis HLB cartridges have a better potential than a cation-exchange sorbent for the extraction of the target drugs from environmental water samples. However, it should be stressed out that the direct application of the tested SPE conditions for the analysis of real environmental water samples is not possible, and such parameters, like volume of loading sample, appropriate solvents for washing and elution steps, and so forth, must be optimized again in order to achieve satisfactory recovery values for the target compounds.

  18. Molecularly imprinted polymer cartridges coupled on-line with high performance liquid chromatography for simple and rapid analysis of dextromethorphan in human plasma samples.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Javanbakht, Mehran; Akbari-Adergani, Behrouz

    2011-04-01

    In this paper, a novel method is described for automated determination of dextromethorphan in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as a sample clean-up technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and dextromethorphan as template molecule. These imprinted polymers were used as solid-phase extraction sorbent for the extraction of dextromethorphan from human plasma samples. Various parameters affecting the extraction efficiency of the MIP cartridges were evaluated. The high selectivity of the sorbent coupled to the high performance liquid chromatographic system permitted a simple and rapid analysis of this drug in plasma samples with limits of detection (LOD) and quantification (LOQ) of 0.12 ng/mL and 0.35 ng/mL, respectively. The MIP selectivity was evaluated by analyzing of the dextromethorphan in presence of several substances with similar molecular structures and properties. Results from the HPLC analyses showed that the recoveries of dextromethorphan using MIP cartridges from human plasma samples in the range of 1-50 ng/mL were higher than 87%. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. An overview of recent progress using low-cost and cost-effective composite materials and processes to produce SSC magnet coils and associated non-metallic parts

    International Nuclear Information System (INIS)

    Morena, J.

    1992-01-01

    Thermoplastic and thermoset polymer systems have been used in high-energy physics applications throughout the world for many years. Like other industries and industrial communities, the materials and processes requirements of these polymers have recently taken on new meanings. New accelerators and other machines are pushing all material parameters beyond limits. New polymeric and composite materials are being developed, invented, and formulated, as is new process and application equipment. This is a decade of change. Composite materials are being chosen for performance characteristics and cost-effective processing as well. The information that follows will note some of the recent progress in the development of composite materials and processes for producing low-cost and cost-effective, high-quality, non-metallic composite components for use in SSC magnets and in other accelerators. The materials and methods for making composite molds, tools, and structural parts for magnet coils and other components are demonstrated. New, unique, and innovative approaches for processing thermoset polymers are presented. The formulated polymer systems are used to form semi and structural insulators, spacers, supports, coil end parts, blocks, housings, adhesives, and other composite applications

  20. Results of the Electron-Beam Button Melting of very clean Ni-base superalloys for the identification of nonmetallic inclusions

    Energy Technology Data Exchange (ETDEWEB)

    Hauner, F.; Stephan, H.; Stumpp, H.

    1986-02-01

    The reliability of components made of high strength materials is substantially influenced by their cleanliness. For example, the ductility, the fatigue-characteristics and the stress resistance of high strength alloys can be improved by increasing the cleanliness along with decreasing the inclusion size to below 25 ..mu..m. For the analysis of such high clean alloys with decreasing size of nonmetallic inclusions, the metallographic texting methods become troublesome and inexact for a dependable quality control. The Electron-Beam Button Melt Test offers a possibility for the examination and qualification of the small amounts of different inclusions in the high clean materials. During a process-controlled melting procedure, inclusions of high density sink to the bottom of a water-cooled copper crucible. Low density inclusions float to the pool surface and are concentrated in the upper center of the button by means of a controlled solidification of the melting pool. For the utilization of the process in the production quality control, development and research, we have developed the Electron-Beam Button Melting Furnace ES 1/07/30 B. In this paper we will present results of the application of the ES1/07/30 B. In this paper we will present results of the application of the ES 1/07/30 B to the EB-Button melting of the Ni-Base Superalloys IN718 and Astroloy. (orig.).

  1. Natural fibre reinforced non-asbestos organic non-metallic friction composites: effect of abaca fibre on mechanical and tribological behaviour

    Science.gov (United States)

    Liu, Yucheng; Ma, Yunhai; Che, Junjian; Duanmu, Lingjian; Zhuang, Jian; Tong, Jin

    2018-05-01

    To obtain a natural fibre reinforced non-asbestos organic non-metallic friction composite with good wear resistance and environmental-friendly performances, friction composites reinforced with different lengths of abaca fibre were fabricated by a compression molder equipment and evaluated by using a constant-speed friction test machine. The worn surface morphologies were observed and analyzed using a Scanning Electron Microscopy (SEM). Experimental results show that the length of abaca fibre had no significant effect on the density and hardness, but was obvious on impact strength. The impact strength increased and then decreased with the increasing of length of abaca fibres. Abaca fibres, especially short fibre (lengths of 5 mm, 10 mm), could improve the wear resistance of the friction composites. Meanwhile, the increase of test temperature could result in the increasing of wear rates of the friction composites. A large amount of secondary plateaux presented on the worn surface of specimens FC1 and FC2 which showe relatively smooth worn surfaces and yield the better wear resistance performance.

  2. Integrated Project Management: A Case Study in Integrating Cost, Schedule, Technical, and Risk Areas

    Science.gov (United States)

    Smith, Greg

    2004-01-01

    This viewgraph presentation describes a case study as a model for integrated project management. The ISS Program Office (ISSPO) developed replacement fluid filtration cartridges in house for the International Space Station (ISS). The presentation includes a step-by-step procedure and organizational charts for how the fluid filtration problem was approached.

  3. On the Debye temperature in the Slack approximation for an estimation of the thermal conductivity of nonmetallic compounds

    International Nuclear Information System (INIS)

    Bruls, R.; Hintzen, H.T.; Metselaar, R.

    2005-01-01

    The value of the Debye temperature of the acoustic modes, as required in the application of Slack's approximation [G. A. Slack, Solid State Physics, edited by F. Seitz, D. Turnbull, and H. Ehrenreich, (Academic, New York, 1979), Vol. 34, pp. 1-71] for the thermal conductivity, is not always available. It is shown that for these cases, the value at the minimum of the curve of the Debye temperature versus the temperature obtained from specific-heat data, gives a good approximation

  4. Integration of a nonmetallic electrostatic precipitator and a wet scrubber for improved removal of particles and corrosive gas cleaning in semiconductor manufacturing industries.

    Science.gov (United States)

    Kim, Hak-Joon; Han, Bangwoo; Kim, Yong-Jin; Yoa, Seok-Jun; Oda, Tetsuji

    2012-08-01

    To remove particles in corrosive gases generated by semiconductor industries, we have developed a novel non-metallic, two-stage electrostatic precipitator (ESP). Carbon brush electrodes and grounded carbon fiber-reinforced polymer (CFRP) form the ionization stage, and polyvinyl chloride collection plates are used in the collection stage of the ESP The collection performance of the ESP downstream of a wet scrubber was evaluated with KC1, silica, and mist particles (0.01-10 pm), changing design and operation parameters such as the ESP length, voltage, and flow rate. A long-term and regeneration performance (12-hr) test was conducted at the maximum operation conditions of the scrubber and ESP and the performance was then demonstrated for 1 month with exhaust gases from wet scrubbers at the rooftop of a semiconductor manufacturing plant in Korea. The results showed that the electrical and collection performance of the ESP (16 channels, 400x400 mm2) was maintained with different grounded plate materials (stainless steel and CFRP) and different lengths of the ionization stage. The collection efficiency of the ESP at high air velocity was enhanced with increases in applied voltages and collection plate lengths. The ESP (16 channels with 100 mm length, 400x400 mm2x540 mm with a 10-mm gap) removed more than 90% of silica and mistparticles with 10 and 12 kV applied to the ESPat the air velocity of 2 m/s and liquid-to-gas ratio of 3.6 L/m3. Decreased performance after 13 hours ofcontinuous operation was recovered to the initial performance level by 5 min of water washing. Moreover during the 1-month operation at the demonstration site, the ESP showed average collection efficiencies of 97% based on particle number and 92% based on total particle mass, which were achieved with a much smaller specific corona power of 0.28 W/m3/hr compared with conventional ESPs.

  5. Research on Lessening of Bonding Effects Between the Metallic and Non-Metallic Surfaces Through the Graphite Films Deposited with Pulsed Electrical Discharges Process

    Science.gov (United States)

    Marin, L.; Topala, P.

    2017-06-01

    The paper presents the results of experimental research on the physics of natural graphite film formation, the establishment of chemical composition and functional properties of the graphite films, formed on metal surfaces, as a result of the action of plasma in the air environment, at a normal pressure, under the electrical discharge in impulse conditions (EDI). The researchings were performed in the frame of doctoral thesis “Research on lessening of the bonding effects between the metallic and nonmetallic surfaces through the graphite films” and aimed to identify the phenomena that occur at the interface metal/ film of graphite, and to identify also the technological applications that it may have the surface treatment for submitting the films of graphite on metallic surfaces achieved through an innovative process of electrical pulsed discharges. After the research works from the PhD theme above mentioned, a number of interesting properties of graphite pellicle have been identified ie reducing of metal surface polarity. This led to drastic decreases for the values of adhesion when bonding of metal surfaces was performed using a structural polyurethane adhesive designed by ICECHIM. Following the thermo-gravimetric analysis, performed of the graphite film obtained by process of electrical pulsed discharges, have been also discovered other interesting properties for this, ie reversible mass additions at specific values of the working temperature Chemical and scanning electron microscopy analysis have revealed that on the metallic surface subjected to electrical pulsed discharges process, outside the graphite film, it is also obtained a series of spatial formation composed of carbon atoms fullerenes type which are responsible for the phenomenon of addition of mass.

  6. Rapid and simple detection of foot-and-mouth disease virus: Evaluation of a cartridge-based molecular detection system for use in basic laboratories.

    Science.gov (United States)

    Goller, K V; Dill, V; Madi, M; Martin, P; Van der Stede, Y; Vandenberge, V; Haas, B; Van Borm, S; Koenen, F; Kasanga, C J; Ndusilo, N; Beer, M; Liu, L; Mioulet, V; Armson, B; King, D P; Fowler, V L

    2018-04-01

    Highly contagious transboundary animal diseases such as foot-and-mouth disease (FMD) are major threats to the productivity of farm animals. To limit the impact of outbreaks and to take efficient steps towards a timely control and eradication of the disease, rapid and reliable diagnostic systems are of utmost importance. Confirmatory diagnostic assays are typically performed by experienced operators in specialized laboratories, and access to this capability is often limited in the developing countries with the highest disease burden. Advances in molecular technologies allow implementation of modern and reliable techniques for quick and simple pathogen detection either in basic laboratories or even at the pen-side. Here, we report on a study to evaluate a fully automated cartridge-based real-time RT-PCR diagnostic system (Enigma MiniLab ® ) for the detection of FMD virus (FMDV). The modular system integrates both nucleic acid extraction and downstream real-time RT-PCR (rRT-PCR). The analytical sensitivity of this assay was determined using serially diluted culture grown FMDV, and the performance of the assay was evaluated using a selected range of FMDV positive and negative clinical samples of bovine, porcine and ovine origin. The robustness of the assay was evaluated in an international inter-laboratory proficiency test and by deployment into an African laboratory. It was demonstrated that the system is easy to use and can detect FMDV with high sensitivity and specificity, roughly on par with standard laboratory methods. This cartridge-based automated real-time RT-PCR system for the detection of FMDV represents a reliable and easy to use diagnostic tool for the early and rapid disease detection of acutely infected animals even in remote areas. This type of system could be easily deployed for routine surveillance within endemic regions such as Africa or could alternatively be used in the developed world. © 2017 The Authors. Transboundary and Emerging Diseases

  7. Pressurized waterproof case electronic device

    KAUST Repository

    Berumen, Michael L.

    2013-01-31

    A pressurized waterproof case for an electronic device is particularly adapted for fluid-tight containment and operation of a touch-screen electronic device or the like therein at some appreciable water depth. In one example, the case may be formed as an enclosure having an open top panel or face covered by a flexible, transparent membrane or the like for the operation of the touchscreen device within the case. A pressurizing system is provided for the case to pressurize the case and the electronic device therein to slightly greater than ambient in order to prevent the external water pressure from bearing against the transparent membrane and pressing it against the touch screen, thereby precluding operation of the touch screen device within the case. The pressurizing system may include a small gas cartridge or may be provided from an external source.

  8. Difference in x-ray scattering between metallic and non-metallic liquids due to conduction electrons

    International Nuclear Information System (INIS)

    Chihara, Junzo

    1987-01-01

    X-ray scattered intensity from a liquid metal as an electron-ion mixture is described using the structure factors, which are exactly expressed in terms of the static and dynamic direct correlation functions. This intensity for a metal is shown to differ from the usual scattered intensity from a non-metal in two points: the atomic form factor and the incoherent (Compton) scattering factor. It is shown that the valence electron form factor, which constitutes the atomic form factor in a liquid metal, leads to a determination of the electron-electron and electron-ion structure factors by combining the ionic structure factor. It is also shown that a part of the electron structure factor, which appears as the incoherent x-ray scattering, is usually approximated as the electron structure factor of the jellium model in the case of a simple metal. As a by-product, the x-ray scattered intensity from a crystalline metal and the inelastic scattering from a liquid metal are given by taking account of the presence of conduction electrons. In this way, we clarify some confusion which appeared in the proposal by Egelstaff et al for extracting the electron-electron correlation function in a metal from x-ray and neutron scattering experiments. A procedure to extract the electron-electron and electron-ion structure factors in a liquid metal is proposed on the basis of formula for scattered intensity derived here. (author)

  9. A Fully Nonmetallic Gas Turbine Engine Enabled by Additive Manufacturing of Ceramic Composites. Part III; Additive Manufacturing and Characterization of Ceramic Composites

    Science.gov (United States)

    Halbig, Michael C.; Grady, Joseph E.; Singh, Mrityunjay; Ramsey, Jack; Patterson, Clark; Santelle, Tom

    2015-01-01

    This publication is the third part of a three part report of the project entitled "A Fully Nonmetallic Gas Turbine Engine Enabled by Additive Manufacturing" funded by NASA Aeronautics Research Institute (NARI). The objective of this project was to conduct additive manufacturing to produce ceramic matrix composite materials and aircraft engine components by the binder jet process. Different SiC powders with median sizes ranging from 9.3 to 53.0 microns were investigated solely and in powder blends in order to maximize powder packing. Various infiltration approaches were investigated to include polycarbosilane (SMP-10), phenolic, and liquid silicon. Single infiltrations of SMP-10 and phenolic only slightly filled in the interior. When the SMP-10 was loaded with sub-micron sized SiC powders, the infiltrant gave a much better result of filling in the interior. Silicon carbide fibers were added to the powder bed to make ceramic matrix composite materials. Microscopy showed that the fibers were well distributed with no preferred orientation on the horizontal plane and fibers in the vertical plane were at angles as much as 45deg. Secondary infiltration steps were necessary to further densify the material. Two to three extra infiltration steps of SMP-10 increased the density by 0.20 to 0.55 g/cc. However, the highest densities achieved were 2.10 to 2.15 g/cc. Mechanical tests consisting of 4 point bend tests were conducted. Samples from the two CMC panels had higher strengths and strains to failure than the samples from the two nonfiber reinforced panels. The highest strengths were from Set N with 65 vol% fiber loading which had an average strength of 66 MPa. Analysis of the fracture surfaces did not reveal pullout of the reinforcing fibers. Blunt fiber failure suggested that there was not composite behavior. The binder jet additive manufacturing method was used to also demonstrate the fabrication of turbine engine vane components of two different designs and sizes. The

  10. Quantitative method of viral pollution determination for large volume of water using ferric hydroxide gel impregnated on the surface of glassfibre cartridge

    Directory of Open Access Journals (Sweden)

    Akira Homma

    1974-01-01

    Full Text Available Quantitative method of viral pollution determination for large volume of water using ferric hydroxide gel impregnated on the surface of glassfibre cartridge filter. The use of ferric hydroxide gel, impregnated on the surface of glassfibre cartridge filter enable us to recover 62.5% of virus (Poliomylitis type I, Lsc strain exsogeneously added to 400 liters of tap-water. The virus concentrator system consists of four cartridge filters, in which the three first one are clarifiers, where the contaminants are removed physically, without significant virus loss at this stage. The last cartridge filter is impregnated with ferric hydroxide gel, where the virus is adsorbed. After the required volume of water has been processed, the last filter is removed from the system and the viruses are recovered from the gel, using 1 liter of glycine/NaOH buffer, at pH 11. Immediately the eluate is clarified through series of cellulose acetate membranes mounted in a 142mm Millipore filter. For the second step of virus concentration, HC1 1N is added slowly to the eluate to achieve pH 3.5-4. MgC1, is added to give a final concentration of 0.05M and the viruses are readsorbed on a 0.45 , porosity (HA cellulose acetate membrane, mounted in a 90 mm Millipore filter. The viruses are recovered using the same eluent plus 10% of fetal calf serum, to a final volume of 3 ml. In this way, it was possible to concentrate virus from 400 liters of tap-water, into 1 liter in the first stage of virus concentration and just to 3 ml of final volume in a second step. The efficiency, simplicity and low operational cost, provded by the method, make it feasible to study viral pollution of recreational and tap-water sources.Relata-se o emprego de um concentrador portátil, o qual se mostrou capaz de recuperar 62,5% dos vírus (Polio I, amostra Lsc experimentalmente dispersos em 400 litros de água, os quais foram reduzidos a 3 ml. O sistema concentrador de vírus é composto de quatro

  11. Award of two contracts for the renting of magnetic tape drives and tape libraries for LHC data storage and the purchase of the associated tape cartridges

    CERN Document Server

    2005-01-01

    This document concerns the award of two contracts for the renting and possible subsequent purchase of magnetic tape drives and tape libraries for LHC data storage. The Finance Committee is invited to agree to the procedure described in section 3 of this document for the evaluation and possible subsequent purchase of tape drives and tape libraries for the storage of data from the LHC experiments. Subject to approval of this procedure, the Finance Committee is further invited to approve the negotiation of a contract for the renting of tape drives and tape libraries for evaluation purposes from IBM, for an amount of 579 707 Swiss francs, and from StorageTek, for an amount of 472 297 Swiss francs, during the period January 2006 â?" March 2007, plus the purchase of the associated tape cartridges for amounts of 202 500 Swiss francs and 284 748 Swiss francs respectively. The Finance Committee will be informed of the results of the evaluation by the end of 2006 and, subject to the outcome, will be invited to approve...

  12. A Method for Multiple Mycotoxin Analysis in Wines by Solid Phase Extraction and Multifunctional Cartridge Purification, and Ultra-High-Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry

    Science.gov (United States)

    Tamura, Masayoshi; Takahashi, Ayumi; Uyama, Atsuo; Mochizuki, Naoki

    2012-01-01

    An analytical method using two solid phase extractions and ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) was developed for the identification and quantification of 14 mycotoxins (patulin, deoxynivalenol, aflatoxins B1, B2, G1, G2, M1, T-2 toxin, HT-2 toxin, zearalenone, fumonisins B1, B2, B3, and ochratoxin A) in domestic and imported wines. Mycotoxins were purified with an Oasis HLB cartridge, followed by a MultiSepTM #229 Ochra. As a result, sufficient removal of the pigments and highly polar matrices from the red wines was achieved. UHPLC conditions were optimized, and 14 mycotoxins were separated in a total of 13 min. Determinations performed using this method produced high correlation coefficients for the 14 mycotoxins (R > 0.990) and recovery rates ranging from 76 to 105% with good repeatability (relative standard deviation RSD < 12%). Twenty-seven samples of domestic and imported wines were analyzed using this method. Although ochratoxin A (OTA) and fumonisins (FMs) were detected in several samples, the FM levels were less than limits of quantification (LOQs) (1 μg/L), and even the largest of the OTA levels was below the EU regulatory level (2 μg/L). These results suggest that the health risk posed to consumers from the wines available in Japan is relatively low. PMID:22822458

  13. Combining selection valve and mixing chamber for nanoflow gradient generation: Toward developing a liquid chromatography cartridge coupled with mass spectrometer for protein and peptide analysis.

    Science.gov (United States)

    Chen, Apeng; Lu, Joann J; Gu, Congying; Zhang, Min; Lynch, Kyle B; Liu, Shaorong

    2015-08-05

    Toward developing a micro HPLC cartridge, we have recently built a high-pressure electroosmotic pump (EOP). However, we do not recommend people to use this pump to deliver an organic solvent directly, because it often makes the pump rate unstable. We have experimented several approaches to address this issue, but none of them are satisfactory. Here, we develop an innovative approach to address this issue. We first create an abruption (a dead-volume) within a fluid conduit. We then utilize an EOP to withdraw, via a selection valve, a train of eluent solutions having decreasing eluting power into the fluid conduit. When these solutions are further aspirated through the dead-volume, these solutions are partially mixed, smoothening concentration transitions between two adjacent eluent solutions. As these solutions are pushed back, through the dead-volume again, a smooth gradient profile is formed. In this work, we characterize this scheme for gradient formation, and we incorporate this approach with a high-pressure EOP, a nanoliter injection valve, and a capillary column, yielding a micro HPLC system. We then couple this micro HPLC with an electrospray ionization - mass spectrometer for peptide and protein separations and identifications. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. SERS as an analytical tool in environmental science: The detection of sulfamethoxazole in the nanomolar range by applying a microfluidic cartridge setup.

    Science.gov (United States)

    Patze, Sophie; Huebner, Uwe; Liebold, Falk; Weber, Karina; Cialla-May, Dana; Popp, Juergen

    2017-01-01

    Sulfamethoxazole (SMX) is a commonly applied antibiotic for treating urinary tract infections; however, allergic reactions and skin eczema are known side effects that are observed for all sulfonamides. Today, this molecule is present in drinking and surface water sources. The allowed concentration in tap water is 2·10 -7  mol L -1 . SMX could unintentionally be ingested by healthy people when drinking contaminated tap water, representing unnecessary drug intake. To assess the quality of tap water, fast, specific and sensitive detection methods are required, in which consequence measures for improving the purification of water might be initiated in the short term. Herein, the quantitative detection of SMX down to environmentally and physiologically relevant concentrations in the nanomolar range by employing surface-enhanced Raman spectroscopy (SERS) and a microfluidic cartridge system is presented. By applying surface-water samples as matrices, the detection of SMX down to 2.2·10 -9  mol L -1 is achieved, which illustrates the great potential of our proposed method in environmental science. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Adsorption of various antimicrobial agents to endotoxin removal polymyxin-B immobilized fiber (Toraymyxin®). Part 2: Adsorption of two drugs to Toraymyxin PMX-20R cartridges.

    Science.gov (United States)

    Shimokawa, Ken-ichi; Takakuwa, Ryotaro; Wada, Yuko; Yamazaki, Noriko; Ishii, Fumiyoshi

    2013-01-01

    In our previous study, the degree of adsorption of 9 representative antimicrobial agents to Toraymyxin(®) PMX-F sheets was quantitatively evaluated. As a result, the adsorption rate was 22.1% for Linezolid in the presence of serum. Therefore, we investigated whether two types of antimicrobial agents (Ciprofroxacin and Linezolid) can be better adsorbed on PMX-F sheets. When the number of PMX-F sheets was increased in a step wise manner, specifically 2, 4, 6, 8 and 12, the adsorption rate increased linearly. In addition, the adsorption to polymyxin-B immobilized fiber (Toraymyxin(®) PMX-20R) cartridges, widely used to remove endotoxins from circulating blood in the treatment of sepsis, was quantitatively evaluated. As a result, in the presence of serum, Linezolid showed adsorption to PMX-20R, and the adsorption rate after 2h was 54.5%, and that after 4h was 65.8%. The results of this study suggest the necessity of monitoring blood antimicrobial concentration during treatment for sepsis with Linezolid, which showed adsorption to PMX-20R in an environment close to a clinical environment. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Pressurized waterproof case for electronic device

    KAUST Repository

    Berumen, Michael L.

    2013-01-31

    The pressurized waterproof case for an electronic device is particularly adapted for the waterproof containment and operation of a touch-screen computer or the like therein at some appreciable water depth. The case may be formed as an enclosure having an open top panel or face covered by a flexible, transparent membrane or the like for the operation of the touch-screen device within the case. A pressurizing system is provided for the case to pressurize the case and the electronic device therein to slightly greater than ambient in order to prevent the external water pressure from bearing against the transparent membrane and pressing it against the touch screen, thereby precluding operation of the touch screen device within the case. The pressurizing system may be a small gas cartridge (e.g., CO2), or may be provided from an external source, such as the diver\\'s breathing air. A pressure relief valve is also provided.

  17. Community Laboratory Testing for Cryptosporidium: Multicenter Study Retesting Public Health Surveillance Stool Samples Positive for Cryptosporidium by Rapid Cartridge Assay with Direct Fluorescent Antibody Testing.

    Directory of Open Access Journals (Sweden)

    Dawn M Roellig

    Full Text Available Cryptosporidium is a common cause of sporadic diarrheal disease and outbreaks in the United States. Increasingly, immunochromatography-based rapid cartridge assays (RCAs are providing community laboratories with a quick cryptosporidiosis diagnostic method. In the current study, the Centers for Disease Control and Prevention (CDC, the Association of Public Health Laboratories (APHL, and four state health departments evaluated RCA-positive samples obtained during routine Cryptosporidium testing. All samples underwent "head to head" re-testing using both RCA and direct fluorescence assay (DFA. Community level results from three sites indicated that 54.4% (166/305 of Meridian ImmunoCard STAT! positives and 87.0% (67/77 of Remel Xpect positives were confirmed by DFA. When samples were retested by RCA at state laboratories and compared with DFA, 83.3% (155/186 of Meridian ImmunoCard STAT! positives and 95.2% (60/63 of Remel Xpect positives were confirmed. The percentage of confirmed community results varied by site: Minnesota, 39.0%; New York, 63.9%; and Wisconsin, 72.1%. The percentage of confirmed community results decreased with patient age; 12.5% of community positive tests could be confirmed by DFA for patients 60 years of age or older. The percentage of confirmed results did not differ significantly by sex, storage temperature, time between sample collection and testing, or season. Findings from this study demonstrate a lower confirmation rate of community RCA positives when compared to RCA positives identified at state laboratories. Elucidating the causes of decreased test performance in order to improve overall community laboratory performance of these tests is critical for understanding the epidemiology of cryptosporidiosis in the United States (US.

  18. Analytical and pre-analytical performance characteristics of a novel cartridge-type blood gas analyzer for point-of-care and laboratory testing.

    Science.gov (United States)

    Oyaert, Matthijs; Van Maerken, Tom; Bridts, Silke; Van Loon, Silvi; Laverge, Heleen; Stove, Veronique

    2018-03-01

    Point-of-care blood gas test results may benefit therapeutic decision making by their immediate impact on patient care. We evaluated the (pre-)analytical performance of a novel cartridge-type blood gas analyzer, the GEM Premier 5000 (Werfen), for the determination of pH, partial carbon dioxide pressure (pCO 2 ), partial oxygen pressure (pO 2 ), sodium (Na + ), potassium (K + ), chloride (Cl - ), ionized calcium ( i Ca 2+ ), glucose, lactate, and total hemoglobin (tHb). Total imprecision was estimated according to the CLSI EP5-A2 protocol. The estimated total error was calculated based on the mean of the range claimed by the manufacturer. Based on the CLSI EP9-A2 evaluation protocol, a method comparison with the Siemens RapidPoint 500 and Abbott i-STAT CG8+ was performed. Obtained data were compared against preset quality specifications. Interference of potential pre-analytical confounders on co-oximetry and electrolyte concentrations were studied. The analytical performance was acceptable for all parameters tested. Method comparison demonstrated good agreement to the RapidPoint 500 and i-STAT CG8+, except for some parameters (RapidPoint 500: pCO 2 , K + , lactate and tHb; i-STAT CG8+: pO 2 , Na + , i Ca 2+ and tHb) for which significant differences between analyzers were recorded. No interference of lipemia or methylene blue on CO-oximetry results was found. On the contrary, significant interference for benzalkonium and hemolysis on electrolyte measurements were found, for which the user is notified by an interferent specific flag. Identification of sample errors from pre-analytical sources, such as interferences and automatic corrective actions, along with the analytical performance, ease of use and low maintenance time of the instrument, makes the evaluated instrument a suitable blood gas analyzer for both POCT and laboratory use. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Clinical evaluation of high-risk HPV detection on self-samples using the indicating FTA-elute solid-carrier cartridge.

    Science.gov (United States)

    Geraets, D T; van Baars, R; Alonso, I; Ordi, J; Torné, A; Melchers, W J G; Meijer, C J L M; Quint, W G V

    2013-06-01

    High-risk human papillomavirus (hrHPV) testing in cervical screening is usually performed on physician-taken cervical smears in liquid-based medium. However, solid-state specimen carriers allow easy, non-hazardous storage and transportation and might be suitable for self-collection by non-responders in screening and in low-resource settings. We evaluated the adequacy of self-collected cervicovaginal (c/v) samples using a Viba-brush stored on an Indicating FTA-elute cartridge (FTA-based self-sampling) for hrHPV testing in women referred to a gynecology clinic due to an abnormal smear. 182 women accepted to self-collect a c/v sample. After self-sampling, a physician obtained a conventional liquid-based cervical smear. Finally, women were examined by colposcopy and a biopsy was taken when clinically indicated. Self-samples required only simple DNA elution, and DNA was extracted from physician-obtained samples. Both samples were tested for 14 hrHPVs by GP5+/6+-EIA-LQ Test and SPF(10)-DEIA-LiPA(25). Both assays detected significantly more hrHPV in physician-collected specimens than in self-collected samples (75.3% and 67.6% by SPF(10); 63.3% and 53.3% by GP5+/6+, respectively). The combination of physician-collected specimen and GP5+/6+ testing demonstrated the optimal balance in sensitivity (98.0%) and specificity (48.1%) for CIN2+ detection in this referral population. A test system of FTA-based self-collection and SPF(10) hrHPV detection approached this sensitivity (95.9%) and specificity (42.9%). These results show that the clinical performance of hrHPV detection is determined by both the sample collection system and the test method. FTA-based self-collection with SPF(10) testing might be valuable when a liquid-based medium cannot be used, but requires further investigation in screening populations. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. [Determination of metformin hydrochloride, melamine and dicyandiamide in metformin hydrochloride preparations by tandem dual solid phase extraction cartridges-high performance liquid chromatography-electrospray ionization multi-stage mass spectrometry].

    Science.gov (United States)

    Zhou, Yanfen; Wang, Fanghuan; Wang, Zelan; Zhan, Haijuan; Liu, Wanyi; Meng, Zhe

    2018-02-08

    A method for the confirmation and quantification of metformin hydrochloride and its relative substances melamine and dicyandiamide using tandem dual solid phase extraction (SPE) cartridges and high performance liquid chromatography-electrospray ionization multi-stage mass spectrometry (HPLC-ESI-MS n ) was developed. The samples were extracted with anhydrous ethanol containing 0.1% (v/v) acetic acid under ultrasound-assisted conditions. The extracts were concentrated and purified using Cleanert PCX and C18 tandem dual solid phase extraction cartridges, and eluted with 5% (v/v) ammonia methanol solution. The separation was performed on a Kromasil-C18 column (100 mm×4.6 mm, 3.5 μm) with gradient elution. The detection was performed in selected ion monitoring (SIM) mode using electrospray ionization multi-stage mass spectrometry. The external standard method was used for quantification. The extraction solvents, types of SPE cartridges and eluents were optimized by comparing the recoveries under different conditions. The results showed that the detector response of each target compound was linear in corresponding mass concentration ranges with the correlation coefficients ( r 2 ) ≥ 0.9992. The limits of detection (LODs) and the limits of quantification (LOQs) of the three analytes were 1.48-13.61 μg/kg and 5.96-45.67 μg/kg, respectively. The recoveries of the three analytes were 65.02%-118.33% spiked at low, medium and high levels. The relative standard deviations (RSDs) were no more than 13.41%. The method is reliable, easy, and has a better purification effect. The method can be applied to the routine analysis of metformin hydrochloride and its relative substances melamine and dicyandiamide in different preparations of metformin hydrochloride.

  1. A Fully Automated Radiosynthesis of [18F]Fluoroethyl-Diprenorphine on a Single Module by Use of SPE Cartridges for Preparation of High Quality 2-[18F]Fluoroethyl Tosylate

    Directory of Open Access Journals (Sweden)

    Gjermund Henriksen

    2013-06-01

    Full Text Available We have developed a new method for automated production of 2-[18F]fluoroethyl tosylate ([18F]FETos that enables 18F-alkylation to provide PET tracers with high chemical purity. The method is based on the removal of excess ethylene glycol bistosylate precursor by precipitation and subsequent filtration and purification of the filtrate by means of solid phase extraction cartridges (SPE. The method is integrated to a single synthesis module and thereby provides the advantage over previous methods of not requiring HPLC purification, as demonstrated by the full radiosynthesis of the potent opioid receptor PET tracer [18F]fluoroethyldiprenorphine.

  2. Direct preparation of a graphene oxide modified monolith in a glass syringe as a solid-phase extraction cartridge for the extraction of quaternary ammonium alkaloids from Chinese patent medicine.

    Science.gov (United States)

    Liang, Xiaojing; Wang, Licheng; Wang, Shuai; Li, Yijing; Guo, Yong

    2017-11-01

    Packed cartridges have been widely used in solid-phase extraction. However, there are still some drawbacks, such as they are blocked easily and the method is time-consuming. In view of the advantages of monoliths, a monolithic extraction material has been directly synthesized in a glass syringe without any gap between the monolith and syringe inner wall. The monolithic syringe was modified with graphene oxide by loading graphene oxide dispersion onto it. The content of graphene oxide and the surface topography of the monolith have been evaluated by elemental analysis and scanning electron microscopy, respectively, which confirmed the successful modification. This prepared graphene oxide-modified monolithic syringe was directly used as a traditional solid-phase extraction cartridge. As expected, it shows good permeability and excellent capability for the extraction of quaternary ammonium alkaloids. The sample loading velocity (1-6 mL/min) does not affect the recovery. Under the optimal conditions, good linearities (R = 0.9992-0.9998) were obtained for five quaternary ammonium alkaloids, and the limits of detection and quantification were 0.5-1 and 1-2 μg/L, respectively. The proposed method was successfully applied for the analysis of quaternary ammonium alkaloids in Chinese patent medicine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Clinical and Surgical Findings and Outcome Following Rumenotomy in Adult Dairy Cattle Affected with Recurrent Rumen Tympany Associated with Non-Metallic Foreign Bodies

    OpenAIRE

    Z. Bani Ismail; A. Al-Majali; K. Al-Qudah

    2007-01-01

    Medical records of 31 adult dairy cows suffering from recurrent rumen tympany for at least 1 month duration that underwent exploratory laparotomy and rumenotomy were reviewed and information was obtained on signalment, history, physical examination findings, laboratory findings and surgical findings. Cases were categorized according to surgical findings into 3 groups. Group 1 (n = 10) included cattle with reticuloruminal, metallic foreign bodies and perireticular adhesions/inflammation, group...

  4. Materials damaging and rupture - Volumes 1-2. General remarks, metallic materials. Non-metallic materials and biomaterials, assemblies and industrial problems

    International Nuclear Information System (INIS)

    Clavel, M.; Bompard, P.

    2009-01-01

    The rupture and damaging of materials and structures is almost always and unwanted events which may have catastrophic consequences. Even if the mechanical failure causes can often be analyzed using a thorough knowledge of materials behaviour, the forecasting and prevention of failures remain difficult. While the macroscopic mechanical behaviour is often the result of average effects at the structure or microstructure scale, the damage is very often the result of the combination of load peaks, of localization effects and of microstructure defects. This book, presented in two volumes, takes stock of the state-of-the-art of the knowledge gained in the understanding and modelling of rupture and damaging phenomena of materials and structure, mostly of metallic type. It gives an outline of the available knowledge for other classes of materials (ceramics, biomaterials, geo-materials..) and for different types of applications (aeronautics, nuclear industry). Finally, it examines the delicate problem, but very important in practice, of the behaviour of assemblies. Content: Vol.1 - physical mechanisms of materials damaging and rupture; rupture mechanics; cyclic plasticity and fatigue crack growth; fatigue crack propagation; environment-induced cracking; contacts and surfaces. Vol.2 - glasses and ceramics; natural environments: soils and rocks; mechanical behaviour of biological solid materials: the human bone; contribution of simulation to the understanding of rupture mechanisms; assemblies damaging and rupture; industrial cases (behaviour of PWR pressure vessel steels, and thermal and mechanical stresses in turbojet engines). (J.S.)

  5. Catalysis under Irradiation in the Presence of Non-Metallic Solids; Catalyse sous irradiation en presence de solides non metalliques; Radiatsionnyj kataliz pri nalichii'nemetallicheskikh tverdykh tel; Radiocatalisis en presencia de solidos no metalicos

    Energy Technology Data Exchange (ETDEWEB)

    Coekelbergs, R.; Crucq, A.; Decot, J.; Degols, L.; Frennet, A.; Lienard, G.; Timmerman, L. [Laboratoire de Chimie Nucleaire, Institut Interuniversitaire des Sciences Nucleaires et Ecole Royale Militaire, Bruxelles (Belgium)

    1963-11-15

    Catalytic processes induced by radiation in the presence of non-metallic solids are discussed, attention being given exclusively to the effects associated with modification of the steady state concentration of charge carriers. The effect of such modification on the kinetics and equilibrium of heterogeneous reactions is quantitatively estimated within the framework of the electronic theory of catalysis, due regard being paid to the electronic characteristics of the surface of the solid. In conclusion, the relationship between these phenomena, catalyst activation and transfer of energy, as previously described, is discussed. (author) [French] Les auteurs discutent des processus catalytiques induits par les radiations en presence de solides non metalliques. Ils considerent exclusivement les effets lies a la modification de la concentration stationnaire des porteurs de charge.- L'influence de cette modification sur la cinetique et l'equilibre des reactions heterogenes est evaluee quantitativement dans le cadre de la theorie electronique de la catalyse et en tenant compte de caracteristiques electroniques de la surface du solide. Enfin, ils discutent la relation existant entre ces phenomenes, l'activation des catalyseurs et le transfert d'energie decrits anterieurement. (author) [Spanish] Los autores examinan los procesos cataliticos inducidos por las radiaciones en presencia de solidos no metalicos. Consideran exclusivamente los efectos vinculados con la modificacion de la concentracion estacionaria de los portadores de carga. Sobre la base de la teoria electronica de la catalisis y teniendo en cuenta las caracteristicas electronicas de la superficie del solido, determinan cuantitativamente la influencia de aquella modificacion sobre la cinetica y el equilibrio de las reacciones heterogeneas. Por ultimo, analizan la relacion que existe entre estos fenomenos, la activacion de los catalizadores y la transmision de energia descritas anteriormente. (author) [Russian

  6. Defects and defect processes in nonmetallic solids

    CERN Document Server

    Hayes, W

    2004-01-01

    This extensive survey covers defects in nonmetals, emphasizing point defects and point-defect processes. It encompasses electronic, vibrational, and optical properties of defective solids, plus dislocations and grain boundaries. 1985 edition.

  7. Nonmetallic and composite materials as solid superleaks

    International Nuclear Information System (INIS)

    Goldschvartz, J.M.

    1982-01-01

    This chapter discusses the devices in general solid porous materials in which the so-called diameter of the pores, gaps, inter-crystalline spaces, or small channels, etc, are equal or smaller than 100 0 A. Examines silicon carbide, wonderstone, talc-stone, rocks as superleaks, magnetic superleaks, the onset point of a superleak, determination of the onset point, and some applications of superleaks (as a filter, as an isotope separator, as a separator in the 3 He- 4 He dilution refrigerator, in a vortex refrigerator, in a servo-valve for liquid helium two (the cocatron), method of measuring the size of sub-microscopic pores, ultra cold neutrons, superconductors pressed into porous materials)

  8. PERSPECTIVE NONMETALLIC RAW MATERIALS AND THEIR UTILIZATION

    Directory of Open Access Journals (Sweden)

    Havelka Jaroslav

    1997-10-01

    Full Text Available It is the existence of the domestic base of raw materials and stable or growing markets that are a precondition for the prospectiveness industrial minerals. Traditional and non-traditional prospective nonmetal-liferous raw materials can be distinguished. The main trends in new industrial applications of industrial minerals are being stated. In the Czech Republic, the following may be ranked among the traditional prospective nonme-talliferous raw materials: kaoline, refractory clays, ceramic and expandable clays, glass and foundry sands, li-mestones, building stones, gypsum, cast basalt, bentonite, diatomite, feldspars, graphite. Alkali rocks, industrial garnets, flaky mica, wollastonite and yet unmined staurolite, minerals of the sillimanite group and others belong to the non-traditional prospective industrial minerals.

  9. A Case Report of Successful Kidney Donation After Brain Death Following Nicotine Intoxication.

    Science.gov (United States)

    Räsänen, M; Helanterä, I; Kalliomäki, J; Savikko, J; Parry, M; Lempinen, M

    Nicotine intoxication is a rare cause of death and can lead to brain death after respiratory arrest and hypoxic-ischemic encephalopathy. To our knowledge, no previous reports regarding organ donation after nicotine intoxication have been described. We present a successful case of kidney donation after brain death caused by subcutaneous nicotine overdose from liquid nicotine from an e-cigarette cartridge in an attempted suicide. Both kidneys were transplanted successfully with immediate graft function, and both recipients were discharged at postoperative day 9 with normal plasma creatinine levels. Graft function has remained excellent in follow-up. This case suggests that kidneys from a donor with fatal nicotine intoxication may be successfully used for kidney transplantation in the absence of other contraindications for donation. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Case Report Case Report

    African Journals Online (AJOL)

    User

    2013-03-26

    Mar 26, 2013 ... c Medicine and Palliative Cancer Care: A Case Report. Sanjoy Kumar Pal ... us complementary and alternative therapies for treatment about the .... controlled trials that homeopathy may be effective for the treatment of ...

  11. Case management.

    Science.gov (United States)

    Woodward, Judy; Rice, Eve

    2015-03-01

    Health care in the United States is changing rapidly under pressure from both political and professional stakeholders, and one area on the front line of required change is the discipline of case management. Historically, case management has worked to defragment the health care delivery system for clients and increase access to health care. Case management will have an expanded role resulting from Affordable Care Act initiatives to improve health care. This article includes definitions of case management, current issues related to case management, case management standards of practice, and a case study of the management of pediatric chronic disease. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Development of nonmetallic solar collector and solar-powered pump

    Science.gov (United States)

    Parker, J. C.

    1979-01-01

    Design and building of two unique components for solar heating (1. flatplate solar collector using no metal components, and 2. solar powered pump for heating and cooling systems are outlined in report. Report also discusses hardware, deliverable end items, problems encountered during fabrication and testing, and performance certification.

  13. Service life evaluation of non-metallic containment seals

    International Nuclear Information System (INIS)

    Pringle, T.G.

    1994-01-01

    A Service Life Evaluation Program (SLEP) was successfully completed for expansion joint seals used in the pressure relief duct of Pickering NGS, an eight unit CANDU station. These seals are part of the containment boundary, are difficult to replace and then only during station outages which are scheduled at ten year intervals. The SLEP, consisting of an accelerated aging program and a qualification test, was undertaken to determine the service life of the seals such that they would be capable of remaining functional following a combination of service life, a design basis accident and a subsequent seismic event. The Arrhenius model of aging was used for the accelerated aging program. Samples of seal material were subjected to oven aging at five temperatures, 150, 160, 170, 180 and 190 deg C. Tensile properties and hardness were measured at various aging times and Arrhenius plots constructed. Based on changes in elongation, activation energies of 1.2 eV and 1.1 eV were calculated for the reinforcing fabric and the silicone cover rubber, respectively. Hardness measurements were also taken but as expected, no precise quantitative aging relationship could be determined from material hardness. For the qualification test a representative length of seal was installed and field-spliced in a test frame built to simulate the installed configuration of the seal. It then underwent accelerated aging equivalent to the service life, followed by LOCA irradiation exposure to LOCA conditions of humidity, temperature and pressure and a design-basis seismic event. Finally, a pressure test to approximately five times design pressure was successfully performed to demonstrate the remaining margin of safety. Periodic air leakage tests indicated no deterioration in sealing performance and no physical deterioration was apparent. (author). 11 refs., 2 tabs., 8 figs

  14. Doped Graphene as Non-Metallic Catalyst for Fuel Cells

    Directory of Open Access Journals (Sweden)

    Adriana MARINOIU

    2017-08-01

    Full Text Available Aiming a commercial development of proton exchange membrane fuel cells (PEMFC, a low cost, sustainable and high performance electrocatalyst for oxygen reduction reaction (ORR with capability to replace/reduce rare metals, are high desirable. In this paper, we present a class of doped graphene, namely iodinated graphene with highly ORR electrochemical performances, synthesized by using the electrophilic substitution method. The prepared samples were characterized by different techniques, including Scanning Electron Microscopy SEM, X-ray photoelectron spectroscopy XPS, Raman spectroscopy, surface area measurement by BET method, that revealed the structure and morphology. The most highly iodinated graphene was tested in a single cell by measuring the cyclic voltammetry. The electrochemical performances were evaluated and compared with a typical PEMFC configuration, when a single cathodic peak at 0.2 V with a current density of – 3.67 mA cm-2 for the Pt/C electrode was obtained. The best electrochemical performances in terms of electrochemical active area, was obtained for a new concept of cathode composed from Pt/C – iodine doped graphene, when a well-defined peak centred at 0.23 V with a current density of approx. – 9.1 mA cm-2 was obtained, indicating a high catalytic activity for ORR.DOI: http://dx.doi.org/10.5755/j01.ms.23.2.16216

  15. Hydrogen diffusion, dissolution and permeation of nonmetallic solids

    International Nuclear Information System (INIS)

    Elleman, T.S.; Rao, D.; Verghese, K.; Zumwalt, L.

    1979-01-01

    A review of hydrogen diffusion, dissolution and permeation in metal oxides, carbides, nitrides, halides and hydrides is presented. Results are organized by compound and an effort has been made to resolve differences between measured results where wide disparities exist. The document has been prepared to provide needed data for the development of fusion reactor blankets but the results should be generally useful in technologies that involve interactions between hydrogen and non-metals

  16. Study of non-metallic inclusion sources in steel

    International Nuclear Information System (INIS)

    Khons, Ya.; Mrazek, L.

    1976-01-01

    A study of potential inclusion sources was carried out at the Tvinec steel plant using an unified labelling procedure for different sources. A lanthanum oxide labelling method has been used for refractories with the subsequent La determination in steel by the neutron activation analysis. Samarium and cerium oxides and the 141 Ce radionuclide have been used in conjunction with the testing. The following sources of exogenous inclusions have been studied: 1)Refractory material comprising fireclay and corundum for steel-teeming trough in open-heart furnaces; 2) Fireclay bottom-pouring refractories; 3) Steel-teeming laddle lining; 4) Heat-insulating and exothermic compounds for steel ingots; 5) Vacuum treatment plant lining; 6) Open-hearth and electric arc furnace slag. The major oxide inclusion source in steel was found to be represented by the furnace slag, since it forms about 40 p.c. of all oxide inclusions. The contributions of the remaining sources did not exceede 5 p.c. each

  17. Study of irradiation effects in non-metallic conductors

    International Nuclear Information System (INIS)

    Atobe, Kozo; Fukuoka, Noboru; Honda, Makoto; Kondo, Tadashi; Morishima, Kouichi; Okada, Moritami; Nakagawa, Masuo

    1998-01-01

    The production of point defects induced by reactor and the thermal behavior of defects in sintered AlN and c-BN have been investigated using the optical absorption and electron spin resonance (ESR) methods. The absorption band at 370 nm (AlN) and the structureless absorption over the visible region are observed. These specimens also show ESR signals with g-value 2.007 (AlN), 2.006 (BN), which are probably caused by N vacancies with a trapped electron. In addition to these experiments, the difference of the photoluminescence(PL) lines on neutron irradiated CZ-Si and FZ-Si has been also studied. The models of the defect associated with neutron irradiation are discussed. (author)

  18. Casing study

    Energy Technology Data Exchange (ETDEWEB)

    Roche, P.

    2000-12-01

    An unorthodox method of casing drilling used by Tesco Corporation at a gas well in Wyoming to drill deeper using casings as drillpipe is discussed. The process involves either rotating the casing as drill string or using a downhole mud motor to rotate the bit. In this instance, the surface hole and the production hole were casing-drilled to a record 8,312 feet by rotating the casing. The 8 1/2-inch surface hole was drilled with 7-inch casing to 1,200 feet using a Tesco underreamer and a polycrystalline pilot bit; drilling and cementing was completed in 12 1/2 hours. The 6 1/4-inch production hole was drilled with 4 1/2-inch casing and the bottomhole assembly was retrieved after 191 hours rotating. This case was the first in which the entire well was casing-drilled from surface to TD. Penetration rate compared favorably with conventional methods: 12 1/2 hours for casing-drilling to 18.9 hours for conventional drilling, despite the fact that the casing-drilling technology is still in its infancy. It is suggested that casing-drilling has the potential to eliminate the need for the drillpipe entirely. If these expectations were to be realised, casing-drilling could be one of the most radical drilling changes in the history of the oil and gas industry. 1 photo.

  19. Case series

    African Journals Online (AJOL)

    abp

    2013-06-20

    Jun 20, 2013 ... ... by a persistent neurological deficit in 2 cases, and infection in 2 cases controlled ... Upper cervical spine injuries are frequent due to increasing number .... the patient; it also takes more time for fracture healing and expose.

  20. Case series

    African Journals Online (AJOL)

    ebutamanya

    2015-01-29

    Jan 29, 2015 ... for tinnitus (Table 1). The otomicroscopic examination shows: central non marginal perforation in 29 patients, posterior perforation in 17 patients and anterior perforation in 14 patients. The tympanic cavity was dry in 27 cases, wet in 18 cases and inflammatory in the. 15 remaining cases. The conralateral ear ...

  1. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-02-12

    Feb 12, 2015 ... Abstract. Vaginal metastasis from pancreatic cancer is an extreme case and often indicates a poor prognosis. We present a case of pancreatic carcinoma with metastasis to the vagina that was discovered by vaginal bleeding. To our knowledge, this is the third case in the world of a primary pancreatic.

  2. Case report

    African Journals Online (AJOL)

    abp

    8 mai 2013 ... subsequent conception and placenta accreta: a case report. American Journal of Obstetrics and Gynecology. September. 2012; 207(3 ) : e7-e8. PubMed | Google Scholar. 5. Umashankar T, Patted S, Handigund R. Endometrial osseous metaplasia: Clinicopathological study of a case and literature review.

  3. Case report

    African Journals Online (AJOL)

    abp

    2015-08-31

    Aug 31, 2015 ... Dual intersection syndrome of the forearm: a case report. Bouchra Zhari1,& ... We reported a case of a 60-year-old man presented to our formation with painful swelling on .... With a fiddling clinical observation and diagnosis.

  4. Case law

    International Nuclear Information System (INIS)

    2016-01-01

    This section treats of the following case laws: 1 - Case Law France: Conseil d'etat decision, 22 February 2016, EDF v. Republic and Canton of Geneva relative to the Bugey nuclear power plant (No. 373516); United States: Brodsky v. US Nuclear Regulatory Commission, 650 Fed. Appx. 804 (2. Cir. 2016)

  5. Case law

    International Nuclear Information System (INIS)

    2015-01-01

    This section treats of the two following case laws: Slovak Republic: Further developments in cases related to the challenge by Greenpeace Slovakia to the Mochovce nuclear power plant; United States: Judgment of the Nuclear Regulatory Commission denying requests from petitioners to suspend final reactor licensing decisions pending the issuance of a final determination of reasonable assurance of permanent disposal of spent fuel

  6. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-10-09

    Oct 9, 2015 ... Aguas SC, Quarracino MC, Lence AN, Lanfranchi-Tizeira HE. Primary melanoma of the oral cavity: ten cases and review of. 177 cases from literature. Medicina oral, patologia oral y cirugia bucal. 2009;14(6):E265-71. PubMed | Google. Scholar. 6. Rapidis AD, Apostolidis C, Vilos G, Valsamis S. Primary.

  7. Case series

    African Journals Online (AJOL)

    ebutamanya

    2016-04-27

    Apr 27, 2016 ... Laparoscopic surgery for groin hernia in a third world country: a report of 9 cases of ... Concerning mesh repair, the (open) LICHENSTEIN and laparoscopic inguinal hernia techniques are ... Two cases were bilateral, 5 unilateral and all of them primary. ... In Africa, This approach is still marginal; few studies.

  8. Case report

    African Journals Online (AJOL)

    ebutamanya

    28 août 2015 ... (intra-osseous synovial cyst) Clinical and therapeutic aspect: case report. Chir Main. 2009 Feb; 28(1):37-41. PubMed |. Google Scholar. 10. Chantelot C, Laffargue P, Masmejean E, Peltier B, Barouk P,. Fontaine C. Fracture of the scaphoid carpal bone secondary to an intraosseous cyst: apropos of a case.

  9. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-01-21

    Jan 21, 2015 ... Published in partnership with the African Field Epidemiology Network (AFENET). (www.afenet.net). Case report. Open Access ... La quantité de tissu neural immature permet d'établir une classification .... Wu X, Han LY, Xu X, Li Z. Recurrent immature teratoma of the ovary: a case report of radical secondary ...

  10. Case Report

    African Journals Online (AJOL)

    the kidney could still be transplanted successfully. We describe a case of high ureteric injury during multi-organ recovery and successful implantation using a Boari flap ureterocystostomy. Case Report. The donor kidney was procured from a 55-year-old male brain stem deceased donor following intra-cerebral hemorrhage.

  11. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-12-04

    Dec 4, 2015 ... was made, while maintaining of valproic acid and clonazepam.This combination allowed a partial remission, allowing a best level of adaptation, it has been maintained. The clozapine has not been tried in this case. Discussion. This case illustrates the presentation of Schizophrenia characterized.

  12. Case series

    African Journals Online (AJOL)

    abp

    2017-07-13

    Jul 13, 2017 ... Its purpose is to assess the clinical and ... Other circumstances of discovery were atrial fibrillation, ... ventricular pacing (9.1%) and blood pressure intolerance to stress ... The mitral flow was a ... anterior mitral valve's pillar was found in one case with a left ... with a stop at the first level in another case.

  13. Case report

    African Journals Online (AJOL)

    raoul

    2011-10-20

    Oct 20, 2011 ... Abstract. A 22-year old man was bitten by a snake on his scrotum. This interesting and unusual case occurred in the rural area of District Aligarh, India. The uniqueness of the case lies in the fact that scrotum is an extremely rare and unusual site for snake bite. Further, with negligible local signs of.

  14. case series

    African Journals Online (AJOL)

    Administrator

    Key words: Case report, case series, concept analysis, research design. African Health Sciences 2012; (4): 557 - 562 http://dx.doi.org/10.4314/ahs.v12i4.25. PO Box 17666 .... According to the latest version of the Dictionary of. Epidemiology ...

  15. CASE STUDY

    African Journals Online (AJOL)

    HIV infection has several oral manifestations, including oral candidiasis and oral hairy leucoplakia. Occasionally unusual presentations requiring rigorous investigations are seen, and in these cases the diagnosis sometimes remains a dilemma owing to limited investigation facilities.1-3 We present the case of a patient who.

  16. Case Report

    African Journals Online (AJOL)

    Sarra

    failure and/or per vaginum (PV) leaN of dialysate. Case report: A ... had PV leaN of the dialysate that was misinterpreted by the .... as part of the management of this infection. On the .... case, we believe that laparoscopy represents a good tool.

  17. Case series

    African Journals Online (AJOL)

    abp

    30 mai 2017 ... All patients underwent systematic plaster immobilization for a period of ... On average, nails were removed after about 6 ... cases), osteitis associated with material (2 cases), refracture (3 ... Although intramedullary nailing ideally is an osteosynthesis ..... intramedullary fixation of pediatric forearm fractures.

  18. Clinical cases

    International Nuclear Information System (INIS)

    Servente, L.

    2012-01-01

    This presentation is about clinical cases and the contribution of the PET - CT Fag application in the diagnosis and treatment of different types of cancer. The cases presented were: neck diseases, epidermoid carcinoma, liver damage and metastasize, lymphoma, thrombosis, colonic cancer and lung disease

  19. Case report

    African Journals Online (AJOL)

    abp

    2015-08-13

    Aug 13, 2015 ... Middle East, Mediterranean region, Central Europe, Australia and. South America) [1, 2]. The incidence of musculoskeletal echinococcosis including involvement of subcutaneous tissue is 1%-. 5.4% among all cases of hydatid disease [2]. In this report, we present a case of recurrent hydatid cysts involving ...

  20. Case report

    African Journals Online (AJOL)

    abp

    2016-02-08

    Feb 8, 2016 ... pituitary metastases can be characteristic and evocative but in no case pathognomic. The diabetes insipidus is the most common clinical manifestation of the disease [2, 3]. We report herein a case of an acute adrenal insufficiency revealing pituitary metastases of lung cancer. Patient and observation.

  1. Clinical case

    International Nuclear Information System (INIS)

    Garcia Fontes, M

    2012-01-01

    This presentation is about a case of a patient with liver tumor. The ultrasound scan and Tc technique were used for the diagnosis and treatment. The application of PET - CT FDG contributed to detect peripheral cholangiocarcinoma, the lymph node distance to guide the therapeutic and the recurrence in case of a negative morphological methods.

  2. 77 FR 11586 - Certain Toner Cartridges and Components Thereof

    Science.gov (United States)

    2012-02-27

    ...., Ltd., d/b/a Huebon Co., Limited, d/b/a Ink-Tank, 3/F, No. 1 Industrial Building, Pingdong 2 Road....V., Avenida del Parque 1175, Monterrey Technology Park, Cienega de Flores, Nuevo Leon, Mexico 65550...., 7611 Green Meadows Drive, Lewis Center, OH 43035. Discount Office Items, Inc., 302 Industrial Drive...

  3. Automated microfluidic cartridges for point-of-care cell counting

    CSIR Research Space (South Africa)

    Smith, S

    2016-10-01

    Full Text Available �PLFURIOXLGLF�FDUWULGJH�GHVLJQ� >�@�ZHUH�PDGH� WR�HQDEOH�DFFXUDWH�EORRG� VDPSOH�DQG�UHDJHQW�GLOXWLRQV�DQG�PL[LQJ�WR�EH�DFKLHYHG���)LJXUH���VKRZV�DQ�H[DPSOH�RI�WKH�LQMHFWLRQ� PROGHG�PLFURIOXLGLF�FDUWULGJH�ZLWK�EOLVWHU�SRXFKHV�XWLOL]HG�IRU�RQ�ERDUG�UHDJHQW�VWRUDJH��D���DV�ZHOO�DV� WKH�SRUWDEOH�VHW�XS...�����PL[LQJ�RI�VDPSOH�DQG�UHDJHQW��DQG����FKDPEHU�IRU�YLVXDOL]DWLRQ�DQG�FHOO�FRXQWLQJ����&DUWULGJH�GL� PHQVLRQV�� �����PP�î� �����PP�î� �PP�� �&DUWULGJHV� DQG� EOLVWHU� SRXFKHV�ZHUH�PDQXIDFWXUHG� E\\�PLFURIOXLGLF� &KLS6KRS�*PE+����E��'UDZLQJ�RI�SRUWDEOH�WHVW�VHW�XS�IRU�FRQWURO�DQG�WHVWLQJ�RI�PLFURIOXLGLF�FDUWULGJHV�� 978-0-9798064-9-0/µTAS 2016/$20©16CBMS...

  4. 21 CFR 520.1450b - Morantel tartrate cartridge.

    Science.gov (United States)

    2010-04-01

    ... grazing season. (2) Indications for use. For control of the adult stage of the following gastrointestinal... dosing gun to all cattle that will be grazing the same pasture. Effectiveness of the drug product is dependent upon continuous control of the gastrointestinal parasites for approximately 90 days following...

  5. Case report of asthma associated with 3D printing.

    Science.gov (United States)

    House, R; Rajaram, N; Tarlo, S M

    2017-12-02

    Three-dimensional (3D) printing is being increasingly used in manufacturing and by small business entrepreneurs and home hobbyists. Exposure to airborne emissions during 3D printing raises the issue of whether there may be adverse health effects associated with these emissions. We present a case of a worker who developed asthma while using 3D printers, which illustrates that respiratory problems may be associated with 3D printer emissions. The patient was a 28-year-old self-employed businessman with a past history of asthma in childhood, which had resolved completely by the age of eight. He started using 10 fused deposition modelling 3D printers with acrylonitrile-butadiene-styrene filaments in a small work area of approximately 3000 cubic feet. Ten days later, he began to experience recurrent chest tightness, shortness of breath and coughing at work. After 3 months, his work environment was modified by reducing the number of printers, changing to polylactic acid filaments and using an air purifier with an high-efficiency particulate air filter and organic cartridge. His symptoms improved gradually, although he still needed periodic treatment with a salbutamol inhaler. While still symptomatic, a methacholine challenge indicated a provocation concentration causing a 20% fall in FEV1 (PC20) of 4 mg/ml, consistent with mild asthma. Eventually, his symptoms resolved completely and a second methacholine challenge after symptom resolution was normal (PC20 > 16 mg/ml). This case indicates that workers may develop respiratory problems, including asthma when using 3D printers. Further investigation of the specific airborne emissions and health problems from 3D printing is warranted. © The Author 2017. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  6. Study of interfacial phenomena of organo-chlorinated steam adsorption on a microporous adsorbent. Case of tri chloro-1,1,1 ethane on activated charcoal

    International Nuclear Information System (INIS)

    Escallon, S.

    1991-06-01

    This study involves the construction and the perfecting of a test system for evaluating the service life of organic vapor cartridges versus 1,1,1 -trichloroethane. Thermogravimetric measurements were carried on in order to suggest a field method to reactive these cartridges, using hot air flow system. Assessment of adsorption rate during experiment is measured with a new electrical method. (author)

  7. Case - Case-Law - Law

    DEFF Research Database (Denmark)

    Sadl, Urska

    2013-01-01

    Reasoning of the Court of Justice of the European Union – Constr uction of arguments in the case-law of the Court – Citation technique – The use of formulas to transform case-law into ‘law’ – ‘Formulaic style’ – European citizenship as a fundamental status – Ruiz Zambrano – Reasoning from...

  8. Dermatology case

    Directory of Open Access Journals (Sweden)

    Catarina Lacerda

    2017-11-01

    Full Text Available Aims: To report a case of uncharacteristic presentation of Parvovirus B19. This virus causes some atypical cutaneous rash such as papular-purpuric “gloves and socks” syndrome which is a rare entity, self-limited and resolves spontaneously to cure. Case Report: Authors describe a case of a six-year-old boy who went to the Emergency Department with a cutaneous rash initially on a finger and then mouth, hands and feet followed by fever. He fully recovered without sequelae. Conclusions: It is important to consider this agent as a possible responsible for atypical purpuric rash.

  9. Dermatology case

    Directory of Open Access Journals (Sweden)

    Fernando Mota

    2017-07-01

    In the present case, the patient was referred to the dermatology department due to an atypical lesion with an uncommon location, revealing the importance of a whole body examination in patients with this disease.

  10. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-10-14

    Oct 14, 2015 ... &Corresponding author: Hanane Massit, Department of Gastroenterology II, Mohamed V ... Crohn's disease, accounting for around 30-50 % of cases, its ... manuscript and have equally contributed to its content and to the.

  11. Case report

    African Journals Online (AJOL)

    abp

    2013-01-09

    . The electrolytes analysis revealed an acute hyponatremia. (sodium concentration 125 mmol/L). Medical treatment consisted of hypertonic saline solution 3%, volume expansion, intubation and ventilation. The presented case ...

  12. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-01-06

    Jan 6, 2015 ... optic disc edema and subsequent formation of a macular star [1]. (Figure 1). ... case of bilateral stellate neuroretinitis due to pheochromocytoma. ... clinical examination are irreplaceable, powerful diagnostic tools that.

  13. Case series

    African Journals Online (AJOL)

    abp

    2017-05-16

    May 16, 2017 ... Hepatocellular carcinoma: a clinicopathological study of 64 cases ... The presenting clinical symptoms were dominated by abdominal pain (n=34), followed by .... malaise, anorexia or weight loss and nausea or vomiting [4].

  14. Case report

    African Journals Online (AJOL)

    abp

    2017-10-10

    Oct 10, 2017 ... A rare case of important and recurrent abnormal uterine bleeding ... 1Department of Obstetrics and Gynecology, University Hospital of Yopougon, Abidjan, Ivory Coast, .... imaging (MRI) could guide us to the diagnosis.

  15. Case Report

    African Journals Online (AJOL)

    Administratör

    Uterus at 17 Weeks of Amenorrhea: Case Report and Literature. Review ... no bleeding but the patient was noted to have ... urinary tract abnormalities are frequent in ... of MRI [6]. Laparoscopy allows formal confirmation of this type of uterine.

  16. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-01-07

    Jan 7, 2015 ... Synchronous malignant renal mass in patient with a Lung cancer: case report and literature ... management and prognosis [4]. Patient and ... classed stage I. The patient got chemo radiotherapy for the lung cancer using ...

  17. Case series

    African Journals Online (AJOL)

    ebutamanya

    2016-06-02

    Jun 2, 2016 ... Epidemiological aspects of suicide attempts among Moroccan children .... Poorly drug intoxication was found in 25% of cases and included over 10 tablets in ... factors have been identified such as maltreatment, sexual abuse.

  18. Case report

    African Journals Online (AJOL)

    abp

    2017-12-13

    Dec 13, 2017 ... nodules measuring 10-6cm, erythematous, purple color, painful at mobilization ... After multi-disciplinary concertation a ... of view than positivity of AR. In contrast ... Katagiri Y, Ansai S. Two cases of cutaneous apocrine ductal.

  19. Case Report

    African Journals Online (AJOL)

    Hamid

    Key words: Case report, composite resin, fiber-reinforced composite. ABSTRACT. A variety of ... investigation will be required to provide additional information on the survival of directly-bonded anterior fixed prosthesis made with FRC systems.

  20. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-11-27

    Nov 27, 2015 ... systemic lupus erythematosus nor other connective tissue disease. Pregnancy was ... day of life, platelet level dropped to 20 x 109/L. The newborn has received platelet ... cases of aplastic anemia or hemolytic anemia [6,7].

  1. Case Report

    African Journals Online (AJOL)

    of permanent hemodialysis (HD) vascular access ... This catheter was removed and a translumbar dialysis ... In this case report, we describe a patient with the ... Rheumatology, the isolated detection of antiphospholipid .... Arthritis Rheum.

  2. Case report

    African Journals Online (AJOL)

    abp

    2016-07-20

    Jul 20, 2016 ... Brain abscess caused by streptococcus constellatus are very rarely ... We present a rare case of a left-sided thalamic abscess caused by streptococcus ... examination showed that the patient was lethargic and had right-.

  3. Case report

    African Journals Online (AJOL)

    abp

    2013-10-17

    Oct 17, 2013 ... We are reporting a case of hemoperitoneum followed by early post partum collapse due to bleeding ... diagnosis of postpartum hemoperitoneum after a vaginal delivery ... The patient was reviewed two weeks after discharge.

  4. Case report

    African Journals Online (AJOL)

    abp

    2012-05-13

    May 13, 2012 ... Missed opportunity for tuberculosis case detection in household contacts in a high ... Maywood, IL, USA, 4College of Public Health, University of Georgia, ... This is an Open Access article distributed under the terms of the ...

  5. Case report

    African Journals Online (AJOL)

    abp

    2017-11-07

    Nov 7, 2017 ... However, auricular disorders are rare and exceptionally inaugural. We describe the case of ... hypothalamic-pituitary axis dysfonction. There was ... tomography, and the salivary gland biopsy confirmed the diagnosis by finding ...

  6. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-03-03

    translucent, hyper-or hypopigmented or erythematous-to- violaceous in color. In addition, epidermal changes may be absent or include atrophy, hyperkeratosis, or telangiectasia [2]. In our case the diagnosis of cutaneous sarcoidosis is ...

  7. Case report

    African Journals Online (AJOL)

    raoul

    2012-02-22

    Feb 22, 2012 ... cancer. Case report. Written informed consent was obtained from the patient for ... colon and rectum (12 patients), uterus (8 patients), ovary (5 patients), head and neck (tongue, pharynx, larynx, nasal cavity, and mandible) (5 ...

  8. Case series

    African Journals Online (AJOL)

    abp

    7 avr. 2016 ... HTA were complicated by heart disease in 24% of cases and by renal disease in 20% of cases ... of clinical specificity. It is not unusual for HTA to be the only manifestation of the disease. In our study we .... Le syndrome de Cushing reste une cause rare d'HTA, sa prévalence dans des centres spécialisés en ...

  9. A study of some radioprotection apparatuses used in the case of pool reactors

    International Nuclear Information System (INIS)

    Robien, E. de; Choudens, H. de; Delpuech, J.

    1965-01-01

    Various problems of radioprotection concerning swimming-pool reactors in Grenoble have led us to study adequate solutions: a) The automatic verification of the staff-radioactivity when coming out of Melusine or Siloe has been realized thanks to a βγ gate which is insensitive to the ambient background in the reactor-hall; b) The automatic verification of the contamination of the shoes of the agents working in these reactors has been realized with a dedicated device; c) The necessity to measure precisely γ doses with the help of an autonomous apparatus has led to the making of a plastic-scintillator γ dosimeter; d) The obligation to forbid the opening of doors in some places where there might be a great intensity of radiation, has led us to make doors open according to the intensity of radiation inside the rooms; e) The releases of radioactive iodine have been measured with activated charcoal cartridges that surround a scintillator connected with a unique channel selector; f) Finally the control of reactor safety rod fall in case of a radioactive accident has been secured by a chain whose detector is a chamber immersed in the swimming-pool, which offers, in the particular case of the hot thickness swimming-pool reactor a double advantage: first it enables us to regulate the upper hot water layer, second to get free of transitory radiations which appear in the reactor hall as the experimental apparatuses are taken out from the core. (authors) [fr

  10. Casing drilling

    Energy Technology Data Exchange (ETDEWEB)

    Heenan, D. [Tesco Corp., Calgary, AB (Canada)

    2003-07-01

    This paper reviewed the experience that Tesco has gained by drilling several wells using only casings as the drill stem. Tesco has manufactured a mobile and compact hydraulic drilling rig called the Casing Drilling {sup TM} system. The system could be very effective and efficient for exploration and development of coalbed methane (CBM) reserves which typically require extensive coring. Continuous coring while drilling ahead, along wire line retrieval, can offer time savings and quick core recovery of large diameter core which is typically required for exploration core desorption tests. The proposed system may also have the potential to core or drill typically tight gas sands or underbalanced wells with air or foam. This would reduce drilling fluid damage while simultaneously finding gas. Compared to conventional drill pipes, Casing Drilling {sup TM} could also be effective with water production from shallow sands because of the smaller annual clearance which requires less air volumes to lift any produced water. 9 figs.

  11. Case Report

    DEFF Research Database (Denmark)

    Bilgin-Freiert, Arzu; Fugleholm, Kåre; Poulsgaard, Lars

    2015-01-01

    We report a case of an intraneural ganglion cyst of the hypoglossal canal. The patient presented with unilateral hypoglossal nerve palsy, and magnetic resonance imaging showed a small lesion in the hypoglossal canal with no contrast enhancement and high signal on T2-weighted imaging. The lesion...... irradiation as an option. This case illustrates a very rare location of an intraneural ganglion cyst in the hypoglossal nerve. To our knowledge there are no previous reports of an intraneural ganglion cyst confined to the hypoglossal canal....

  12. Case law

    International Nuclear Information System (INIS)

    2012-01-01

    This section gathers the following case laws: 1 - Canada: Judicial review of Darlington new nuclear power plant project; Appeal decision upholding criminal convictions related to attempt to export nuclear-related dual-use items to Iran: Her Majesty the Queen V. Yadegari; 2 - European Commission: Greenland cases; 3 - France: Chernobyl accident - decision of dismissal of the Court of Appeal of Paris; 4 - Slovak Republic: Aarhus Convention compliance update; 5 - United States: Judgement of a US court of appeals upholding the NRC's dismissal of challenges to the renewal of the operating licence for Oyster Creek Nuclear Generating Station; reexamination of the project of high-level waste disposal site at Yucca Mountain

  13. The Application of Non-Metallic Core Materials in a High-Temperature Reactor Experiment; Utilisation de materes non metalliques dans le coeur d'un reacteur experimental a haute temperature; Ispol'zovanie nemetallicheskikh materialov dlya aktivnoj zony vysokotemperaturnogo opytnogo reaktora; Empleo de materiales no metalicos en el nucleo de un reactor experimental de alta temperatura

    Energy Technology Data Exchange (ETDEWEB)

    Huddle, R. A.U.; Shepherd, L. R. [Organization for Economic Co-Operation and Development, Dragon Project, Atomic Energy Establishment, Winfrith, Dorset (United Kingdom)

    1963-11-15

    The OECD High-Temperature Reactor Project (DRAGON) was set up to develop the technology of high-temperature gas-cooled reactors and, as part of this development, to construct and operate a 20-MW(t) reactor experiment. The reactor, which is now nearing completion, is a helium-cooled system with a coreoutlet temperature of 750{sup o}C; it employs U{sup 235} fuel with thorium as a fertile material. A particular feature of this system is the absence of any metals in the core. Because of the high temperatures involved, namely, up to 1050{sup o}C at fuel element surfaces and above, 1500{sup o}C in-the hottest regions of the fuel, refractory nonmetallic materials are employed. All the core material is incorporated within the fuel element which leads to a high ratio of heat transfer surface area to core volume and hence permits a high average power density leading to a relatively compact system. Each fuel element consists of a cluster of graphite tubes, containing the fissile and fertile materials as carbides incorporated in graphite pellets. A purge flow of the helium coolant passing through the centre of each fuel rod is extracted from the base whence it passes into a helium processing plant to remove fission products and other impurities before being returned to the reactor. This procedure reduces the escape of fission products from the very hot ceramic fuel into the primary coolant stream. Problems associated with the development and production of ceramic fuel bodies and graphite for this reactor, and the behaviour of these materials under operating conditions are outlined. Some experience from irradiation and in-pile loop investigations are reported. The main emphasis in this programme is on the development of the high-temperature gas-cooled reactor for application as an economic power producing system. (author) [French] Les objectifs du Projet DRAGON de l'OCDE (reacteur a haute temperature) sont les suivants: ameliorer la technologie des reacteurs a haute temperature

  14. Case report

    African Journals Online (AJOL)

    abp

    2015-11-23

    Nov 23, 2015 ... found the presence of deletion of ELN locus, compatible with. Williams-Beuren syndrome. The diagnosis of Williams-Beuren syndrome was made, and the patient is under observation, with a decline of eight months. Discussion. This paper is about an original case of Williams-Beuren syndrome associated ...

  15. Case series

    African Journals Online (AJOL)

    ebutamanya

    10 déc. 2015 ... 5. Chandler JR, Langenbrunner DJ, Stevens ER. The Pathogenesis. Of Orbital complications in acute sinusitis. Laryngoscope. 1970. Sep; 80(9): 1414-28. PubMed | Google Scholar. 6. Hodges E, Tabbara KF. Orbital cellulitis: review of 23 cases from Saudi Arabia. Br J Ophthalmol. 1989 Mar; 73(3): 205-8.

  16. Case report

    African Journals Online (AJOL)

    abp

    2012-06-11

    Jun 11, 2012 ... Abstract. Churg Strauss syndrome is a rare systemic and pulmonary vasculitis exceptionally associated with AA amyloidosis. We report the case of a 65-year old woman with past medical history of asthma. She developed polyarthralgia, headache and purpura. A laboratory workout found hypereosinophilia ...

  17. Case report

    African Journals Online (AJOL)

    ebutamanya

    2016-04-14

    Apr 14, 2016 ... Abstract. Laparoscopic management of acute adhesive small bowel obstruction has been shown to be feasible and advantageous. However, widespread acceptance and application is still not observed. We describe the case report of a 58-year-old male who presented with signs and symptoms of.

  18. Case report

    African Journals Online (AJOL)

    abp

    and imperforate anus. Figure 3: The examination of the spinal column revealed a spina bifida occulta. References. 1. Varygin V, Bernotas S, Gurskas P, Karmanovas V, et al. Cloacal exstrophy: a case report and literature review. Medicina. 1978;. 47(12): 682-5. PubMed| Google Scholar. 2. Carey JC, Greenbaum B, Hall BD.

  19. Case report

    African Journals Online (AJOL)

    raoul

    12 août 2010 ... Estermann F, B Denis, P Gaucher, D Regent, and D Sondag. Pneumatosis cystoides of the colon: knowing how to recognize it - Apropos of 8 cases. Ann Gastroenterol Hepatol (Paris). 1994; 30(4): 151-155. This article on PubMed. 12. Pun YL, DM Russell, GJ Taggart, and DR Barraclough. Pneumatosis ...

  20. Case report

    African Journals Online (AJOL)

    abp

    un cas. Rev Chir Orthop Reparatrice. Appar Mot. 2000;86(1):98-103. PubMed | Google Scholar. 7. Nagamine N, Nohara Y, Ito E. Elastofibroma in Okinawa. A clinicopathologic study of 170 cases. Cancer. 1982;50(9):1794-.

  1. Case series

    African Journals Online (AJOL)

    abp

    14 oct. 2013 ... Nagamine N, Nohara Y, Ito E. Elastofibroma in Okinawa - A clinicopathologic study of 170 cases. Cancer. 1982;50(9):1794-. 805. PubMed | Google Scholar. 12. Schafmayer C, Kahlke V, Leuschner I, Pai M, Tepel J. Elastofibroma dorsi as differential diagnosis in tumors of the thoracic wall. Ann Thorac Surg.

  2. Case report

    African Journals Online (AJOL)

    abp

    2015-05-18

    May 18, 2015 ... Abstract. Vasa previa is a rare but clinically important obstetrical complication that can be associated with a low-lying placenta or placenta previa. We aim to present one case of vasa previa diagnosed during the placenta examination after the caesarean indicated for triple uterus scar. A 26-year-old.

  3. Case report

    DEFF Research Database (Denmark)

    Füchtbauer, Laila; Brusgaard, Klaus; Ledaal, Pål

    2015-01-01

    ey Clinical Message Vitamin D-dependent rickets type 1 VDDR-1 is a recessive inherited disorder with impaired activation of vitamin D, caused by mutations in CYP27B1. We present long-time follow-up of a case with a novel mutation including high-resolution peripheral quantitative computed tomography...

  4. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-01-14

    Jan 14, 2015 ... In addition, rare but life-threatening complications such as foreign body aspiration in the air passages may also be seen. Aspirated foreign bodies include teeth, implants, mechanical supports or materials used during procedures. We report two separate cases of aspiration risk developing during the course.

  5. Case report

    African Journals Online (AJOL)

    abp

    2013-02-19

    Feb 19, 2013 ... main disease and 70-80% stenosis of the proximal Left Anterior Descending Artery (LAD). ... He had a successful PTCA + DES stent to the LAD (Figure 3). ... In the case being presented, despite the benign appearance of the.

  6. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-02-27

    Feb 27, 2015 ... custody is an additional risk factor in the development of this complication. [4] After a dural tear, the majority of anesthesiologists, as was the case in our observation, search the epidural space in an intervertebral spacing or sus- underlying for epidural analgesia [5, 6]. However, it should be emphasized that.

  7. Case report

    African Journals Online (AJOL)

    abp

    2013-10-23

    Oct 23, 2013 ... Pyomyositis in Nodding Syndrome (NS) patient - a case report ... B0X 7072, Kampala, Uganda, 3Gulu University, Faculty of Medicine, P.O. B0X 166, Gulu, Uganda .... to pay particular attention to such children who may have.

  8. Case series

    African Journals Online (AJOL)

    abp

    2014-01-20

    Jan 20, 2014 ... Page number not for citation purposes. 1. Stroke in young adults: about 128 cases ... hypercholesterolemia, history of cigarette smoking, contraceptive intake treatment, alcohol intake, sexual ..... Carolei A, Marini C, Ferranti E, Frontoni M, Prencipe M, Fieschi. C. A prospective study of cerebral ischemia in ...

  9. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-09-10

    Sep 10, 2015 ... Abstract. To describe a case of breast cancer manifested by cerebellar syndrome and to establish a relationship between breast cancer and Paraneoplastic syndromes through the presence of anti- yo antibodies in serum and cerebrospinal fluid of a patient. Our patient was 52 years old, Multipara with 5.

  10. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-11-20

    Nov 20, 2015 ... We report a case of a farmer who has sustained of a severe hand wound due to ... open distal interphalangeal joint dislocation of the 5th finger; flexor tendons were .... biomechanical analysis and clinical application. J Orthop ...

  11. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-12-03

    Dec 3, 2015 ... surgical correction by high way by the Huntington technique or. Haultain or vaginally with the technique of Spinelli [1] - hysterectomy hemostasis remains the gold standard in case of persistent bleeding but is exceptionnel [6]. More recently the use of balloons such as Rusch or Bakri have been described in ...

  12. Case report

    African Journals Online (AJOL)

    abp

    26 avr. 2016 ... cases relating idiopathic gastric necrosis in a young patient who presented no heart failure, or particular psychological profiles (bulimia, anorexia) no venous or arterial thrombosis were found during surgical exploration during the pathological study, no toxic or bacteriological founded. Gastric necrosis is ...

  13. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-11-24

    Nov 24, 2015 ... High drug level and the absence of toxic effect (or the absence of toxic .... from the first order,"in which the extent of metabolism is directly correlated with the ... hepatocyte, the pancreatic ductuli, the glandular epithelial cells of ... cytochrome P-450 genes in diseases requiring chronic drug use. In our case ...

  14. Case report

    African Journals Online (AJOL)

    raoul

    25 sept. 2011 ... Robin A, Méry G, George JL, Maalouf T, Angioi K. Facial necrotizing fasciitis after mild trauma of the eyelid: role of nonsteroidal anti- inflammatory treatment. J Fr Ophtalmol. 2010 Oct;33(8):568-72. This article on PubMed. 6. Cornelia Poitelea, Michael J. Wearne. Periocular necrotising fasciitis--a case report.

  15. Case Report

    African Journals Online (AJOL)

    Arthritis: a Case Report. Intissar Haddiya*, Hakima Rhou, Loubna Benamar, Fatima Ezzaitouni, Rabia Bayahia, Naima. Ouzeddoun. Unit of Nephrology, Ibn Sina University Hospital, Rabat, Morocco. * Corresponding author; Unit of Nephrology, Ibn Sina University. Hospital, Rabat, Morocco; E. mail: intissarhaddiya@hotmail.

  16. Case series

    African Journals Online (AJOL)

    abp

    2017-07-14

    Jul 14, 2017 ... complications. Various methods have been used to treat these injuries, with variable results. The aim ... Soft tissue healing occurred without need for plastic surgery in all cases. ... Under general anesthesia, patients were placed in the supine .... of the ankle joint is another advantage of the ILIZAROV device.

  17. Case report

    African Journals Online (AJOL)

    abp

    2014-03-28

    Mar 28, 2014 ... Abstract. Cushing syndrome is a hormonal disorder caused by prolonged exposure of body tissue to cortisol. We report two cases of iatrogenic Cushing's syndrome in two Nigerian children following intranasal administration of aristobed-N (Betamethasone+Neomycin) given at a private hospital where.

  18. Case law

    International Nuclear Information System (INIS)

    Anon.

    1999-01-01

    This paper gives and analyses three examples of case law: decision rejecting application to close down Tomari nuclear power plant (Japan); judgement by the Supreme Administrative Court on the closing of Barsebaeck (Sweden); litigation relating to the Department of Energy's obligations under the Nuclear Waste Policy Act to accept spent nuclear fuel and high-level radioactive waste (United States). (A.L.B.)

  19. Case series

    African Journals Online (AJOL)

    abp

    4 déc. 2017 ... modify initial tumor stage in 60% of cases: upstaging in 23 patients (46%) and downstaging in ... (FDG) est injecté chez nos patients à la dose de 4 à 5 MBq/kg par ..... positron emission tomography in patients with lung cancer.

  20. Case Report

    African Journals Online (AJOL)

    through a small clinically-undetectable inguinal hernia, and may require ... conservative approach may be adopted. Case report: An 80 ... gross bilateral scrotal swelling (without cough impulse) ... Tenckhoff catheter was inserted using the open surgical technique ... role of surgery in treating dialysate leaks presenting as.

  1. case study

    African Journals Online (AJOL)

    Elton

    particularly in patients who commence ART with low CD4 counts and established opportunistic infections. IRIS results from a pathological inflammatory response to pre-existing infective, host or other antigens, alive or dead, causing clinical deterioration in HIV-infected patients after initiating ART.1 A case definition for IRIS ...

  2. Case series

    African Journals Online (AJOL)

    abp

    19 oct. 2017 ... Traitement des amyloses AL systémiques: à propos de 25 cas. Treatment of systemic AL amyloidosis: about 25 cases. Hicham Eddou1,&, Ali Zinebi1, Hicham El Maaroufi2, Mohammed Karim Moudden1, Kamal Doghmi2, Mohammed Mikdame2,. Mohammed El Baaj1. 1Service de Médecine Interne, Hôpital ...

  3. Case report

    African Journals Online (AJOL)

    ebutamanya

    15 janv. 2015 ... Les biopsies faites étaient revenues négatives. L'échographie abdominale a montré une masse au .... PubMed | Google. Scholar. 8. Nassiopoulos K, Stockhammer A, Hahnloser P, et al. Gastric leiomyoblastoma: literature review and report of a case. Rev. Med Suisse Romande .1997; 117 (2):147-150.

  4. Case report

    African Journals Online (AJOL)

    abp

    21 mai 2013 ... biopsie vaginale est revenue en faveur d'un ADK colloïde muqueux, franchement marqué par l'anti-corps anti-CK 20 .... Google Scholar. 7. Mudhar HS, Smith JH, Tidy J. Primary vaginal adenocarcinoma of intestinal type arising from an adenoma: case report and review of the literature. Int J Gynecol Pathol.

  5. CASE STUDY

    African Journals Online (AJOL)

    2011-06-02

    Jun 2, 2011 ... immunosuppression associated with HIV/AIDS puts them at a higher risk of developing oesophageal cancer. 47. CASE STUDY. A 49-year-old man was diagnosed as HIV infected, with a CD4 count of 60 cells/µl. He was started on an antiretroviral treatment regimen comprising zidovudine, lamivudine and ...

  6. Case report

    African Journals Online (AJOL)

    abp

    27 oct. 2017 ... We report the case of a menopausal woman with breast tuberculosis in order to raise concern for diagnosis. Key words: Tuberculosis, breast, diagnosis. Introduction. La tuberculose mammaire est une forme rare de la tuberculose extra-pulmonaire même dans les pays endémiques. Elle représente. 0,06 à 0 ...

  7. Case report

    African Journals Online (AJOL)

    abp

    2017-10-17

    Oct 17, 2017 ... Scholar. 2. Riccardo Campi, Sergio Serni, Maria Rosaria Raspollini,. Agostino Tuccio, Giampaolo Siena, Marco Carini et al. Robot-. Assisted Laparoscopic Vesiculectomy for Large Seminal Vesicle. Cystadenoma: a case report and review of the literature. Clinical Genitourinary Cancer. 2015; 13(5): e369-.

  8. Case series

    African Journals Online (AJOL)

    abp

    2017-09-15

    15 Ebola Virus Disease (EVD) outbreak in West Africa infected more than 28,000 persons out of which 11,000 died [20]. At the height of this outbreak, the huge load of cases and their contacts overwhelmed the response ...

  9. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-01-07

    Jan 7, 2015 ... Preeclampsia is an entity that may present from 20th week of gestation up to 48 hours postpartum and is associated with hypertension and ... The awareness of atypical cases of preeclampsia enhances early diagnosis and management which are critical to ... hypertensive disorder in previous pregnancy.

  10. Case report

    African Journals Online (AJOL)

    raoul

    28 avr. 2011 ... Spermatic cord sarcoma in adults. J Urol. 1978; 120: 301-305. This article on PubMed. 11. Romero Tenorio M, Farinas Varo JM, Baez Perez JM, Almaised J, Ramirez Chamorro R, and Beltran Ruiz-Hinestrosa M. Liposarcoma en la infancia: Aportacion de un case exceptional - Revision de la literatura.

  11. Case report

    African Journals Online (AJOL)

    abp

    2017-09-04

    Sep 4, 2017 ... Published in partnership with the African Field Epidemiology Network (AFENET). (www.afenet.net). Case report ... occurrence during infancy; and development from neural crest cells. [1, 5]. In a histological review, .... with adjuvant treatment is suggested for recurrent lesions [3, 17]. All of these have been ...

  12. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-11-17

    Nov 17, 2015 ... Abstract. Here we report a case of central retinal artery occlusionrevealing an ischemic cardiomyopathy. A 54-year old smoker man presented at the hospital because of sudden visual loss in his left eye. There was cherry-red spot in the macula in his left eye. We performed a fluorescein angiogram and.

  13. Case report

    African Journals Online (AJOL)

    abp

    2016-05-13

    May 13, 2016 ... Abstract. We report a rare case of an elderly woman presented with right renal mass with invasion of renal vein and several small lymphadenopathy in the hilar area .the diagnosis of kidney cancer is suspected and the patient underwent open radical nephrectomy, surrenalectomy and lymphadenectomy ...

  14. CASE REPORT

    African Journals Online (AJOL)

    NJSR

    cardiac failure, as in our patient, digitalis and radiography are considered before surgical excision. Occasional cases have involuted spontaneously, though a few have metastasized. 5 Other forms of treatment include corticosteroids, and hepatic artery ligation. 7 Malignant transformation has been reported after successful ...

  15. Case report

    African Journals Online (AJOL)

    abp

    2017-05-05

    May 5, 2017 ... Chondroblastic osteosarcoma of the distal tibia: a rare case report. Aymen Ben Fredj1,&, Lassaad Hassini1, Aymen Fekih1, Mohamed Allagui1, Issam Aloui1, Abderrazek Abid1. 1Department of Orthopaedic Surgery, University Hospital, Monastir, Tunisia. &Corresponding author: Aymen Ben Fredj, ...

  16. Case series

    African Journals Online (AJOL)

    ebutamanya

    2015-01-20

    Jan 20, 2015 ... The brainstem, cerebral white matter, basal ganglia, internal capsule, thalamus and spinal cord were involved in forty four, thirty one, thirty, twenty nine, seventeen and four patients, respectively. The cerebral peduncle was the brainstem structure mainly involved with thirty cases followed by the pons with, ...

  17. Case report

    African Journals Online (AJOL)

    abp

    Abstract. Primary omental torsion is a rare cause of acute abdominal pain, we report a case of 10-year-old boy admitted with crampy abdominal pain, routine laboratory tests and plain abdominal radiography was normal, the patient underwent surgical exploration with the initial diagnosis of appendicitis, primary omental ...

  18. Case report

    African Journals Online (AJOL)

    Raoul

    2009-10-15

    Oct 15, 2009 ... Meckel's diverticulum: a case report from the University Hospital Center ... The Pan African Medical Journal - ISSN 1937-8688. ... Usually discovered incidentally; it is often the cause of acute abdominal emergencies. It may present as intestinal obstruction with volvulus, intussusceptions or peritonitis due to ...

  19. Case report

    African Journals Online (AJOL)

    abp

    16 janv. 2017 ... We report the case of a 70-year-old man with no past medical history presenting with laryngeal dyspnea associated with low abundant paroxysmal hemoptysis. The patient underwent nasofibroscopy showing the presence of a living and mobile organism at the subglottic level evoking a leech. Extraction ...

  20. Case report

    African Journals Online (AJOL)

    abp

    2016-02-29

    Feb 29, 2016 ... Classification of subtrochanteric femoral fractures. Injury. 2010. Jul;41(7):739-45. PubMed | Google Scholar. 3. Kennedy MT, Mitra A, Hierlihy TG, Harty JA, Reidy D, Dolan M. Subtrochanteric hip fractures treated with cerclage cables and long cephalomedullary nails: a review of 17 consecutive cases over. 2.

  1. Case report

    African Journals Online (AJOL)

    abp

    2016-07-14

    Jul 14, 2016 ... sarcoma mimicking abscess: review of the MRI appearances. Skeletal Radiol. 2001; 30:173 -7. PubMed | Google Scholar. 6. Adrian HO, Louis SL, Howard AO, Kenneth WA, John RG. Epithelioid sarcoma of the penis: Report of an unusual case and review of the literature. Ann Diagn Patho. 2000; 14(2):88-.

  2. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-02-13

    Feb 13, 2015 ... mucoid, T.inkin, T. cutaneum) a rate of 11.15%. This rate confirms the one recorded by Pini G & al ... The authors declare no competing interest. Authors' ... due to Trichosporonasahii,first two cases in Chile. Rev. IberoamMicol.

  3. Case Report

    DEFF Research Database (Denmark)

    Klubien, Jeanett; Borgersen, Dorte Winther; Rosenberg, Jacob

    2016-01-01

    Introduction Perforation of the gallbladder is a benign and common complication during laparoscopic cholecystectomy. However, it may result in stone spilling, which potentially can lead to serious postoperative complications.  Case report A 70-year-old male underwent laparoscopic cholecystectomy...

  4. Case Report

    DEFF Research Database (Denmark)

    Sylvester-Hvid, Amalie; Avnstorp, Magnus B; Wagenblast, Lene

    2017-01-01

    Introduction Breast seroma may be caused by a variety of factors including lymphatic disruption, continuous inflammation and foreign bodies such as breast implants. In cases of breast implants associated seroma the diagnosis of Anaplastic Large Cell Lymphoma (ALCL) should be investigated. Present...

  5. Case report

    African Journals Online (AJOL)

    abp

    2015-07-10

    Jul 10, 2015 ... We herein describe a case of a 22-year-old man with a long history of cocaine abuse. ... African Medical Journal - ISSN 1937-8688. This is an Open Access article distributed under the terms of the Creative Commons Attribution ... a long history of cocaine, cannabis, and tobacco abuse. He presented to our.

  6. Case report

    African Journals Online (AJOL)

    ebutamanya

    19 févr. 2016 ... Enteropathy associated T-cell lymphoma (EATL) is a rare complication of celiac disease (CD). We report a case of EATL associated with CD revealed by acute intestinal obstruction. A North African woman of 38 years old with a history of infertility and chronic abdominal pain was admitted in emergency with ...

  7. Case report

    African Journals Online (AJOL)

    abp

    27 avr. 2016 ... Dysphagia revealing aberrant right subclavian artery: about a case. Abdelilah Mouhsine1,&, Oualid Bakzaza2, El Mehdi Atmane1, Ahmed Belkouch3, Redouane Rokhssi1, Youssef Berrada1, Mostapha. Alaoui2, M'barek Mahfoudi1, Abdelghani El Fikri1. 1Service de Radiologie, HMA, Marrakech, Maroc, ...

  8. Case report

    African Journals Online (AJOL)

    abp

    2014-05-30

    May 30, 2014 ... tumor size, pleural effusion, response to chemotherapy, and optimal radiotherapy [10]. Several authors assert that Surgical therapy has the most important implication and complete surgical resection is associated with a survival advantage [5]. In the index case, despite no distant metastasis were found at.

  9. Case report

    African Journals Online (AJOL)

    abp

    2013-08-29

    Aug 29, 2013 ... inflammatory bowel disease, in particular ulcerative colitis (UC), are often treated with immunosuppressive therapy and can develop colorectal KS [3]. We report the case of a human immunodeficiency negative-virus (HIV) man, with a severe refractory UC, who was treated with steroids, azathioprine and ...

  10. Case report

    African Journals Online (AJOL)

    abp

    5 mai 2016 ... Garcia JA, Garcia-Fernandez M, Romance A, Sanchez JC. Wandering spleen and gastric volvulus. Pediatr Radiol. 1994;. 24(7): 535-6. PubMed | Google Scholar. 3. Melikoglu M, Colak T, Kasasoglu. Two unusual cases of wandering spleen requiring splenectomy. Eur J Pediatr Surg. 1995; 5(1): 48-9.

  11. Case report

    African Journals Online (AJOL)

    ebutamanya

    French). 1984;30(3):177-81. PubMed |. Google Scholar. 12. Isla A, Paz JM, Sansivirini F, Zamora P, Garcia Grande A,. Fernandez A. Intramedullary spinal cord metastasis: a case report. J Neurosurg Sci. 2000 Jun; 44(2):99-101.

  12. Case report

    African Journals Online (AJOL)

    abp

    2013-05-21

    May 21, 2013 ... Imperforate Hymen - a rare cause of acute abdominal pain and tenesmus: case report and review of .... did a ten year retrospective analysis of the data of 15 patients treated for ... Low back pain (38-40%) [4, 13, 14]. Occurs as ...

  13. Case report

    African Journals Online (AJOL)

    abp

    2017-06-13

    Jun 13, 2017 ... Oxyuriasis's symptoms are extremely diverse in children, ranging from nausea, diarrhea, insomnia, irritability, recurrent cellulitis, loss of appetite, nightmares and endometritis. Here we report a curious case of oxyuriasis in the settings of a refugee camp in Greece. The patient was a. 10-year old Syrian ...

  14. Case report

    African Journals Online (AJOL)

    abp

    15 juin 2016 ... We report the case of a 17-year old admitted with diffuse bone pain, hypercalcemia and thrombopenia. Bone scan showed .... plus rares et ont été rapportée dans des observations isolées [13]. ... hypercalcemia in nude mice.

  15. Case series

    African Journals Online (AJOL)

    abp

    1 juin 2012 ... ... Ren- Xuan Guo, and Ke-Jian Guo. Adult intussusception: A retrospective review of 41 cases. World J Gastroenterol. 2009 Jul 14;15(26):3303-8. This article on PubMed. 14. Abou-Nukta F, Gutweiler J, Khaw J, Yavorek G. Giant lipoma causing a colo-colonic intussusception. Am Surg. 2007;73(4):417. This.

  16. Case report

    African Journals Online (AJOL)

    abp

    2013-02-14

    Feb 14, 2013 ... Abstract. Vaginal metastases of renal cell carcinoma have been rarely described. We report a case of a 75-year old woman, who underwent radical right nephrectomy for a renal cell carcinoma. Tumour was classified pT3bN0M0 and grade III of Furhmann grading. One year later, scanner discovered.

  17. Case report

    African Journals Online (AJOL)

    abp

    2013-11-04

    Nov 4, 2013 ... especially in developing countries. HBV can be complicated by acute glomerulonephritis , this association remains controversial. The optimal therapy is undefined, although in several studies, the antiviral drugs and the immunosuppressive therapy have been tried for those patients [1]. We report the case of ...

  18. Case report

    African Journals Online (AJOL)

    ebutamanya

    17 janv. 2016 ... Budd-Chiari syndrome: a rare complication of hepatic sarcoidosis (about one case). Ismael Ait Sghier1,&, Nabil Moatassim Billah1. 1Service de Radiologie Centrale, Hôpital Avicenne, Rabat, Maroc. &Corresponding author: Ismael Ait Sghier, Service de Radiologie Centrale, Hôpital Avicenne, Rabat, Maroc.

  19. Case competitions

    DEFF Research Database (Denmark)

    Schjoldager, Anne Gram

    2009-01-01

    The paper presents and discusses a teaching project with case competitions for MA students of specialised translation at the Aarhus School of Business, Aarhus University. Drawing on a series of online questionnaires, the paper ascertains how the project was evaluated by the participating students...

  20. Case report

    African Journals Online (AJOL)

    abp

    Cerebral venous sinus thrombosis in HIV-infected patients: report of 2 cases ... often affects young adults and children [1]. ... local trauma and infection, prothrombotic states like nephrotic ... head trauma. ... She denied any history of alcohol intake, cigarette smoking .... against protein S among HIV infected patients, leading to.

  1. Case report

    African Journals Online (AJOL)

    abp

    9 août 2017 ... We report a case of hemorrhagic stroke of the brainstem in a nonmonitored ... haemorrhagic stroke of the brainstem on the second post-operative day after cesarean section performed due to suspicion of retroplacental haematoma arisen .... syndrome hémorragique ont évolué favorablement et une patiente.

  2. Case series

    African Journals Online (AJOL)

    abp

    2015-01-19

    Jan 19, 2015 ... Child sexual abuse: report of 311 cases with review of literature. Laila Essabar1, Abdenbi Khalqallah2, Badr Sououd Benjelloun Dakhama1,&. 1Department of Paediatric Medical Emergencies of Rabat children's Hospital, Morocco, 2Laboratory of Clinical and Pathological Psychology,. Mohammed V ...

  3. CASE REPORT

    African Journals Online (AJOL)

    2011-12-02

    Dec 2, 2011 ... brain illustrated enhancement of the optic nerves post-. CASE REPORT ... improved bilaterally to 6/18 on the right and 6/12 on the left. There was .... the possible risks versus benefits of steroid therapy and invite them to ...

  4. Case report

    African Journals Online (AJOL)

    raoul

    2011-06-10

    Jun 10, 2011 ... The authors report the case of a patient admitted with right ... secondary locations of kidney cancers are lung, bone, liver and brain. ... thrombus (left) or inferior vena cava (right), promote the spin-cell ... They reported a median survival of 13.6 months for nephrectomy plus interferon group vs 7.8 months for ...

  5. Case report

    African Journals Online (AJOL)

    cqq1a

    20 sept. 2010 ... Desplypere JP, Pract M, Verdonk G. An unusual case of trichobezoar: The Rapunzel Syndrome. Am J Gastroenterol. 1982 Jul;77(7):467-. 7. This article on PubMed. 9. Kaushik NK, Sharma YP, Negi A, Jaswal A. Images - Gastric trichobezoar. Ind J Radiol Imag. 1999;9(3):137-139. 10. Newman B, Girdany ...

  6. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-05-05

    May 5, 2015 ... Abstract. We report a new case of osteogenesis imperfecta (OI) type II which is a perinatal lethal form. First trimester ultrasound didn't identified abnormalities. Second trimester ultrasound showed incurved limbs, narrow chest, with hypomineralization and multiple fractures of ribs and long bones. Parents ...

  7. Case report

    African Journals Online (AJOL)

    2012-09-11

    Sep 11, 2012 ... Abstract. Solid pseudopapillary tumor (SPN) of the pancreas is a rare tumor, but has favorable prognosis. It is typically observed in young women. Only few cases have been reported in young men. We report the observation of a 73-year-old man presented with a palpable mass in the left upper abdomen.

  8. Case series

    African Journals Online (AJOL)

    raoul

    3 mars 2011 ... Martin RG. Malignant tumors of the small intestine. Surg Clin North Am. 1986; 66: 779-785. This article on PubMed. 5. Hatzaras I, Palesty JA, Abir F, Sullivan P, Kozol RA, Dudrick SJ, Longo WE. Small-bowel tumors: epidemiologic and clinical characteristics of 1260 cases from the connecticut tumor registry.

  9. CASE STUDY

    African Journals Online (AJOL)

    2010-09-01

    Sep 1, 2010 ... of the two diseases surgery can be successful, recovery can be similar to that .... lymphocytes predominated in 68% of cases, and that there was an .... using ferritin is the fact that it acts as an acute-phase reactant and will be ...

  10. The Case for Case Reports

    Directory of Open Access Journals (Sweden)

    George R. Saade

    2011-09-01

    Full Text Available If you are reading a hard copy of this editorial, then you are holding in hand the first issue of the American Journal of Perinatology Reports, or AJP Reports as we like to refer to it. Welcome to AJP Reports and thank you for taking the time to peruse it. I hope you find many of the reports interesting and helpful. The editorial team and publisher are very pleased to be able to bring this journal to our readers. Judging by the journal title, the editorial team, and the layout you may have already guessed that this is a companion to the American Journal of Perinatology. We will continue to publish original articles and topical reviews in the American Journal of Perinatology, but all case reports or case series will be referred to AJP Reports. Some may question the need for more case reports. Our decision to start AJP Reports obviously indicates that we think that case reports can be useful. I can refer to several diseases, treatment complications, and procedures that were first brought to the attention of healthcare providers through case reports. The best example of the usefulness of case reports is probably in infectious diseases. In the early phases of an emerging infectious disease, the case report or case series are usually the first clues of a problem. HIV was first brought to the attention of the medical community by case reports.[1] [2] [3] In our own field, the first attempts at treatment of twin-to-twin transfusion syndrome (TTTS using laser coagulation were reported in a case series.[4] After additional reports about the use of laser in TTTS, a randomized trial was performed that cemented laser photocoagulation as a therapeutic modality for TTTS.[5] While case reports or series are not considered the highest form of evidence, they are frequently the first form of evidence and the nudge that starts the cascade of investigation that ultimately leads to high-level evidence. Therefore, their impact on clinical practice may be easily

  11. Radiological case

    International Nuclear Information System (INIS)

    Giraldo Estrada, Horacio

    2001-01-01

    The paper analyze the case of a patient (65 year-old) masculine, who consults for precordial pain associated to dyspnoea, left scapular pain and in the shoulder of the same side, of 3 days of evolution that it has been permanent and progressive. He also refers, loss of weight the last 6 months and dyspnoea of effort of 1 month of evolution. He denies chill, fever, cough or expectoration. The patient presents gastric ulcer tried for 1 year, smoker of 2 packages of daily cigarettes of the 15 to the 40 years; all its life worked in masonry. X-rays of the thorax and Tac, among other analyses were done and the case is discusses

  12. Case Report

    DEFF Research Database (Denmark)

    Søborg, Marie-Louise Kulas; Rosenberg, Jacob; Burcharth, Jakob

    2016-01-01

    Guillain-Barré syndrome (GBS) is an acute ascending peripheral neuropathy, caused by autoimmune damage of the peripheral nerves. GBS can be divided into three subtypes: acute inflammatory demyelinating neuropathy, acute motor axonal neuropathy, and the more rare type, acute motor and sensory axonal...... neuropathy (AMSAN). Reports of AMSAN with onset after epidural anesthesia and spinal surgery are extremely rare, and the linkage between development of GBS and neuroaxial anesthesia remains conclusively unconfirmed. We present a case in which the patient developed subacute motor and predominantly sensory...... neuropathy following epidural blockade. The case emphasizes the need of including AMSAN in differential diagnostic considerations to changes in motor and sensory function following epidural anesthesia, allowing accelerated rehabilitation and relevant alleviating therapy....

  13. Case law

    International Nuclear Information System (INIS)

    2014-01-01

    This section of the Bulletin brings together the texts of the following case laws: Canada: - Judgment of the Federal Court of Canada sending back to a joint review panel for reconsideration the environmental assessment of a proposed new nuclear power plant in Ontario. France : - Conseil d'etat, 24 March 2014 (Request No. 358882); - Conseil d'etat, 24 March 2014 (Request No. 362001). Slovak Republic: - Further developments in cases related to the challenge by Greenpeace Slovakia to the Mochovce nuclear power plant; - Developments in relation to the disclosure of information concerning the Mochovce nuclear power plant. United States: - Initial Decision of the Atomic Safety and Licensing Board Ruling in Favour of Nuclear Innovation North America, LLC (NINA) Regarding Foreign Ownership, Control or Domination

  14. Case04

    DEFF Research Database (Denmark)

    Vestergaard, Flemming; Karlshøj, Jan; Hauch, Peter

    Casestudiets formål er at beskrive og måle en større entreprenørvirksomheds omkostninger og gevin-ster ved at anvende metoder og værktøjer, der er modelbaserede. Case 04 tager udgangspunkt i et konkret byggeprojekt, hvor BIM teknologien er anvendt på et for den danske entreprenørbranche rela...

  15. Automatic mesh generation for finite element calculations in the case of thermal loads

    International Nuclear Information System (INIS)

    Cords, H.; Zimmermann, R.

    1975-01-01

    The presentation describes a method to generate finite element nodal point networks on the basis of isothermals and flux lines. Such a mesh provides a relatively fine partitioning at regions where pronounced temperature variations exist. In case of entirely thermal loads a net of this kind is advantageous since the refinement is provided at exactly those locations where high stress levels are expected. In the present contribution the method was employed to analyze the structural behavior of a nuclear fuel element under operating conditions. The graphite block fuel elements for high temperature reactors are of prismatic shape with a large number of parallel bores in the axial direction. Some of these bores are open at both ends and cooling is effected by helium flowing through. Blind holes contain the fuel as compacts or cartridges. The basic temperature distribution in a horizontal section of the block was obtained by the boundary point least squares method which yields analytical expressions for both temperature and thermal flux. The corresponding computer code was presented at an earlier SMiRT conference. The method is particularly useful for regular arrays of heat sources and sinks as encountered in heat exchanger problems. The generated mesh matches the requirements of a subsequent structural analysis with finite elements provided there are no other than thermal loads

  16. Case law

    International Nuclear Information System (INIS)

    Anon.

    2011-01-01

    This chapter gathers three case laws, one concerning France and the two others concerning the United States. France - Decision of the Administrative Court in Strasbourg on the permanent shutdown of the Fessenheim nuclear power plant: On 9 March 2011, the administrative court in Strasbourg confirmed the government's rejection to immediately close the Fessenheim nuclear power plant, the first unit of which started operation on 1 January 1978. The court rejected the motion of the 'Association trinationale de protection nucleaire' (ATPN) filed against the decision of the Minister of Economy, Industry and Employment to refuse the final shutdown of the plant. The group, which brings together associations as well as French, German and Swiss municipalities, had taken legal action in December 2008. United States - Case law 1 - Judgment of a US Court of Appeals on public access to sensitive security information and consideration of the environmental impacts of terrorist attacks on nuclear facilities: This case concerns 1) the public's right to access classified and sensitive security information relied upon by the US Nuclear Regulatory Commission (NRC) in its environmental review; and 2) the sufficiency of the NRC's environmental review of the impacts of terrorist attacks for a proposed Independent Spent Fuel Storage Installation (ISFSI). In 2003, the NRC ruled that the National Environmental Policy Act (NEPA) did not require the NRC to consider the impacts of terrorist attacks in its environmental review for the proposed ISFSI at the Diablo Canyon Power Plant. ' NEPA mandates that all federal agencies must prepare a detailed statement on the environment impacts before undertaking a major federal action that significantly affects the human environment. In 2004, the San Luis Obispo Mothers for Peace, a group of individuals who live near the Diablo Canyon Power Plant, filed a petition in the US Court of Appeals for the Ninth Circuit challenging the NRC's 2003 decision. The

  17. Dermatology case

    Directory of Open Access Journals (Sweden)

    Catarina Moreira

    2017-12-01

    Full Text Available Over the years, with advances in the understanding of the disease, general improvement in health standards and nutrition, scurvy is now rarely encountered. Dermatologic signs may be the only manifestation and are often misdiagnosed. Awareness of manifestations and prompt diagnosis are essential because, with appropriate vitamin replacement, scurvy is readily treated. We report the case of an adolescent whose diagnosis of scurvy was based on the recognition of dietary risk factors, the presence of dermatologic manifestations and the rapid resolution of skin lesions when vitamin C supplements were initiated.

  18. Case law

    International Nuclear Information System (INIS)

    2016-01-01

    This section treats of the following case laws: 1 - Canada: Decision of the Canadian Federal Court of Appeal dismissing an appeal related to an environmental assessment of a project to refurbish and extend the life of an Ontario nuclear power plant; 2 - Poland: Decision of the Masovian Voivod of 28 December 2015 concerning the legality of the resolution on holding a local referendum in the Commune of Rozan regarding a new radioactive waste repository (2015); 3 - United States: Commission authorises issuance of construction permit for the Shine Medical Isotope Facility in Janesville, Wisconsin; 4 - United States: Commission authorises issuance of combined licences for the South Texas Project site in Matagorda County, Texas

  19. Case Law

    International Nuclear Information System (INIS)

    2014-01-01

    This section treats of the following case laws sorted by country: 1 - Germany: Federal Administrative Court confirms the judgments of the Higher Administrative Court of the Land Hesse: The shutdown of nuclear power plant Biblis blocks A and B based on a 'moratorium' imposed by the Government was unlawful; List of lawsuits in the nuclear field. 2 - Slovak Republic: Further developments in cases related to the challenge by Greenpeace Slovakia to the Mochovce nuclear power plant; Developments in relation to the disclosure of information concerning the Mochovce nuclear power plant. 3 - United States: Judgment of the Nuclear Regulatory Commission resuming the licensing process for the Department of Energy's construction authorisation application for the Yucca Mountain high-level radioactive waste repository; Judgment of the Licensing Board in favour of Shaw AREVA MOX Services regarding the material control and accounting system at the proposed MOX Facility; Dismissal by US District Court Judge of lawsuit brought by US military personnel against Tokyo Electric Power Company (TEPCO) in connection with the Fukushima Daiichi nuclear power plant accident

  20. Clinical Case

    Directory of Open Access Journals (Sweden)

    Luca Apicella

    2011-01-01

    Full Text Available Renal sinus lipomatosis (RSL represents an abnormal proliferation of the adipose tissue surrounding the renal pelvis of uncertain origin, associated with aging, obesity, steroid excess, infections, and calculosis. It represents a rare complication in transplanted kidneys, and, despite the accurate and prolonged radiological followup of transplanted organs, only a few cases of RSL have been described in graft recipients, with no remarkable effects on renal function. The diagnosis relies on ultrasonography (US, magnetic resonance imaging (MRI, computed tomography (CT, and, finally, percutaneous biopsy. We describe the case of an extensive RSL in a 38-year-old renal transplant recipient, diagnosed by ultrasonography and computed tomography. The patient underwent a radiologic study because of an acute, asymptomatic renal impairment, that led to the diagnosis of a RSL of unusual dimensions, associated with a discrete hydronephrosis. Paradoxically, after a short course of steroids, the recovery of renal function and the partial resolution of calyceal dilatation were observed. The rarity of this affection, the need of a differential diagnosis with fat-containing tumors, and the possibility of parenchymal inflammation associated with RSL, potentially responsive to steroids, are also discussed.

  1. Imaging Case

    Directory of Open Access Journals (Sweden)

    Maria Adriana Rangel

    2018-04-01

    Full Text Available Introduction: Cephalohematoma is a collection of serosanguineous fluid below the periosteum and is the most frequent cranial injury in the newborn, occurring in 0.2-2.5% live births. The majority of cephalohematomas spontaneously resolve within three to four weeks, however, some persist beyond four weeks and begin to calcify. Case report: A seven-week-old boy, was referred to the emergency department because of a head lump on the right parietal region, with no other symptoms. He was born after a vacuum-assisted delivery, and presented a cephalohematoma in the first days of life, that progressively decreased and became more rigid. Physical examination, revealed a cranial asymmetry, and a head lump on the right parietal region, that was hard and fixed to the bone. Head X-ray revealed a radiopaque lump on the right parietal bone and a poorly defined arched line, as well as visible microcalcifications on the core of the cephalohematoma, typical findings of a calcified cephalohematoma. Discussion: Even though cephalohematoma is frequently encountered, calcified cephalohematoma is seen only sporadically, and is a rare clinical entity. History and clinical examination are important in the differential diagnosis and imaging strategy. Radiography and ultrasonography are often the initial screening diagnostic tests, followed by magnetic resonance imaging or computed tomography. Head x-ray features, in this case report, where particularly evocative of the diagnosis.

  2. Case Law

    International Nuclear Information System (INIS)

    Anon.

    2009-01-01

    Different case law are presented in this part: By decision dated 17 july 2009, the Ontario Court of Appeal (Canada) has ruled on the scope of solicitor-client privilege and the protections that may be afforded to privileged investigations reports. The decision reaffirms the canadian court system view of the importance of the protection of solicitor-client privilege to the administration of justice; For United states here is a judgment of a U.S. court of Appeals on the design basis threat security rule (2009), this case concerns a challenge to the U.S. Nuclear regulatory commission (N.R.C.) revised design basis threat rule, which was adopted in 2007 (nuclear bulletin law no. 80). The petitioners public citizen, Inc., San Luis Obispo Mothers for Peace and the State of New York filed a lawsuit in the U.S. court of appeals for the Ninth circuit alleging that the N.R.C. acted arbitrarily and capriciously and in violation of law by refusing to include the treat of air attacks in its final revised design basis rule. On the 24. july 2009, a panel of three ninth circuit judges rules 2-1 that the N.R.C. acted reasonably in not including an air treat in its design basis rule. Secondly, judgment of a U.S. court of appeals on consideration of the environmental impact of terrorist attacks on nuclear facilities (2009), this case concerns the scope of the U.S. Nuclear regulatory commission environmental analysis during its review of applications to re-licence commercial nuclear power plants. New Jersey urged the N.R.C. to consider the environmental impact of an airborne terrorist attack on the power plant, arguing that such analysis was required by the national environmental policy act (N.E.P.A.). On 31. march 2009, a panel of three circuit judges declined to follow the ninth circuit opinion and affirmed NRC decision 3-0 ruling that NRC was not required to consider terrorism in its N.E.P.A. analysis because NRC re-licensing would not be a reasonably close cause of terrorism

  3. Case law

    International Nuclear Information System (INIS)

    Anon.

    2008-01-01

    Canada: Brunswick News Inc. versus Her Majesty the Queen in the Right of the Province of New Brunswick denying release of nuclear power feasibility study: A superior court in Canada has made an important decision with regard to freedom of information legislation and protection of confidential commercial information. It denied a provincial newspaper company access to a feasibility study concerning the construction of a second nuclear power reactor in New Brunswick. U.S.A.: In the Court of federal Claims, plaintiffs Carolina Power and Light Company and Florida power corporation (collectively Progress Energy) claimed damages of U.S.D. 91 029 704 from defendant U.S. Department of Energy (D.O.E.), under the terms of D.O.E. standard contract for Disposal of spent nuclear fuel and/or high level waste. D.O.E. liability was previously established and the amount of damages was the sole issue in this case.Germany: in 2005, the federal Ministry for the Environment, Nature Conservation and Nuclear Safety (B.M.U.) instructed the regulatory and supervisory body of the federal state Baden-Wurtemberg to issue an order, which required the operator to shut its plant, without delay or further orders, in case of not obviously insignificant non-compliance with technical limits, measures or other specific safety-related requirements deemed to control incidents. The operator was further required to inform the regulatory and supervisory body immediately if it was no longer able to demonstrate the controllability of design basis accidents. In the judgement of the Federal Administrative court, the instruction to stop operation is too ambiguous since it does not specify with technical criteria should compel operators to shut their reactors.The court rules that, in compliance with the principle that administrative decisions must be precise, clear and unambiguous, an order to terminate operations must clearly state when and for what reasons an operator has this duty. a global obligation to

  4. Case law

    International Nuclear Information System (INIS)

    Anon.

    2007-01-01

    Concerning the France, the judgement of the European Court of Human Rights on the Right to a fair Trial, in the litigation Collectif Stop Melox and Mox versus France (2007) and the decision of the Council of State Quashing a decree concerning a nuclear installation in Brennilis, for the want of public information and consultation (2007) are reported. For South Africa, the judgment of the Cape High Court in the case of Mc donald and others versus Minister of Minerals and Energy and others (2007) is reported. United Kingdom states the decision of the Wick Sheriff Court Fining UKAEA for plutonium exposure (2007). Concerning Usa the judgment of the US Court of Appeals on environment Analysis of the effects of terrorism (2006) and the vacatur of US Court of Federal Claims Decision regarding Price-Anderson Compensation of Costs in a private Tort Claim (2007) are reported. (N.C.)

  5. Endoscopic case

    Directory of Open Access Journals (Sweden)

    Fernando Pereira

    2017-01-01

    Full Text Available We present the case of a ten-year-old female patient referred to Gastroenterolgy consultation for abdominal pain and cramping, usually worse after eating, recurring diarrhoea, hypochromic and microcytic anaemia with low serum iron and ferritin levels. Moderate to severe Crohn’s disease of the terminal ileum e right colon (L3 was diagnosed, based on endoscopic image and biopsy. The patient was treated with prednisone and azathioprine, but after one year of treatment she was steroids dependent and treatment was switched to infliximab. One year after beginning this treatment, the patient achieved remission (clinical and laboratorial parameters. A control colonoscopy showed mucosal healing with scars and deformation with stenosis of ileocecal valve (Figures 1-2. Surgical intervention will be probably necessary in near future.

  6. Case Series.

    Science.gov (United States)

    Vetrayan, Jayachandran; Othman, Suhana; Victor Paulraj, Smily Jesu Priya

    2017-01-01

    To assess the effectiveness and feasibility of behavioral sleep intervention for medicated children with ADHD. Six medicated children (five boys, one girl; aged 6-12 years) with ADHD participated in a 4-week sleep intervention program. The main behavioral strategies used were Faded Bedtime With Response Cost (FBRC) and positive reinforcement. Within a case-series design, objective measure (Sleep Disturbance Scale for Children [SDSC]) and subjective measure (sleep diaries) were used to record changes in children's sleep. For all six children, significant decrease was found in the severity of children's sleep problems (based on SDSC data). Bedtime resistance and mean sleep onset latency were reduced following the 4-week intervention program according to sleep diaries data. Gains were generally maintained at the follow-up. Parents perceived the intervention as being helpful. Based on the initial data, this intervention shows promise as an effective and feasible treatment.

  7. Case Study: Testing with Case Studies

    Science.gov (United States)

    Herreid, Clyde Freeman

    2015-01-01

    This column provides original articles on innovations in case study teaching, assessment of the method, as well as case studies with teaching notes. This month's issue discusses using case studies to test for knowledge or lessons learned.

  8. Case law

    International Nuclear Information System (INIS)

    2013-01-01

    This section reports on 7 case laws from 4 countries: - France: Conseil d'Etat decision, 28 June 2013, refusing to suspend operation of the Fessenheim nuclear power plant; - Slovak Republic: New developments including the Supreme Court's judgment in a matter involving Greenpeace Slovakia's claims regarding the Mochovce nuclear power plant; New developments in the matter involving Greenpeace's demands for information under the Freedom of Information Act; - Switzerland: Judgment of the Federal Supreme Court in the matter of the Departement federal de l'environnement, des transports, de l'energie et de la communication (DETEC) against Ursula Balmer-Schafroth and others on consideration of admissibility of a request to withdraw the operating licence for the Muehleberg nuclear power plant; - United States: Judgment of the Court of Appeals for the District of Columbia Circuit granting petition for writ of mandamus ordering US Nuclear Regulatory Commission (NRC) to resume Yucca Mountain licensing; Judgment of the Court of Appeals for the Second Circuit invalidating two Vermont statutes as preempted by the Atomic Energy Act; Judgment of the NRC on transferring Shieldalloy site to New Jersey's jurisdiction

  9. Case law

    International Nuclear Information System (INIS)

    Anon.

    2006-01-01

    Five articles are tackled: in France, the judgement of the Court of Appeal of Limoges concerning the dumping of radioactive waste by Areva N.C.(2006). The Court of Appeal of Limoges ruled that Areva N.C. was not guilty of dumping radioactive waste, and neither had it infringed radiation protection regulations or general mining industry regulations. there was no proof of damage to fish fauna. In Sweden, judgement on Plans for the dismantling of Barsebaeck (2006). This court case resulted from a dispute between the operator and the Swedish government Swedish radiation Protection Institute. The Swedish Government wanted decommissioning to commence immediately whereas plant management at Barsebaeck had indicated its intention to wait until 2020, when the radiation dose to workers during decommissioning work would be lower. The court approved the plans to commence dismantling in 2020, when a repository for large reactor components will be ready at the national final repository for radioactive waste at the Forsmark plant. In United Kingdom, on October 2006, British Nuclear group Sellafield Ltd. (B.N.G.S.L.) was fined 500 000 pounds (G.B.P.) plus G.B.P. 68000 in costs in a case brought by the UK health and Safety Executive (H.S.E.) for failing to identify and stop an eight-month long leak of 83 400 litres of radioactive liquid at the Thermal Oxide reprocessing Plant (T.H.O.R.P.) at Sellafield in Cumbria. The fine was levied at Carlisle Crown Court after B.N.G.S.L. pleaded guilty, at an earlier hearing, to the three counts of breaching conditions attached to the Sellafield site licence, granted under the 1965 Nuclear Installations Act as amended. These conditions require the licensee to make and comply with written instructions; to ensure safety systems are in good working order; and to ensure radioactive material is contained and, if leaks occur, they are detected and reported. In Usa, in accordance with the Nuclear Waste Policy Act of 1982, as amended (N.W.P.A.) the US

  10. Case law

    International Nuclear Information System (INIS)

    2017-01-01

    This section treats of the following case laws (United States): 1 - Virginia Uranium, Inc. v. Warren, 848 F.3d 590 (4. Cir. 2017): In the United States District Court for the Western District of Virginia, the plaintiffs, a collection of uranium mining companies and owners of land containing uranium deposits, challenged a Commonwealth of Virginia moratorium on conventional uranium mining. The plaintiffs alleged that the state moratorium was preempted by federal law under the Supremacy Clause of the US Constitution.; 2 - United States v. Energy Solutions, Inc.; Rockwell Holdco, Inc.; Andrews County; Holdings, Inc.; and Waste Control Specialists, LLC. (D. Del. June 21, 2017): In 2016, the United States, acting through the US Department of Justice, commenced an action in United States District Court in Delaware seeking to enjoin the acquisition of Waste Control Specialists, LLC (WCS) and its parent company by Energy Solutions, Inc., and its parent. WCS and Energy Solutions are competitors in the market for the disposal of low-level radioactive waste (LLRW) produced by commercial generators of such material. The United States alleged that the proposed acquisition was unlawful. 3 - Cooper v. Tokyo Electric Power Company, No. 15-56426 (9. Cir. 2017): The plaintiffs are US Navy service members who were deployed off the Japanese coast as part of the US effort to provide earthquake relief after the 9.0 earthquake and tsunami that struck Japan on 11 March 2011. Plaintiffs sued alleging 'that TEPCO was negligent in operating the Fukushima Daiichi Nuclear Power Plant and in reporting the extent of the radiation leak

  11. Case law

    International Nuclear Information System (INIS)

    2015-01-01

    This section treats of the following case laws: 1 - Canada: Decision of the Canadian Federal Court of Appeal overturning a decision to send back for reconsideration an environmental assessment of a proposed new nuclear power plant in Ontario; 2 - France: Council of State decision, 28 November 2014, Federation 'Reseau sortir du nucleaire' (Nuclear Phase-Out network) and others vs. Electricite de France (EDF), Request No. 367013 for the annulment of: - The resolution of the French Nuclear Safety Authority (ASN) dated 4 July 2011 specifying additional regulations for Electricite de France (EDF) designed to strengthen the reactor basemat of reactor No. 1 in the Fessenheim nuclear power plant, and - The resolution of ASN dated 19 December 2012 approving the start of work on reinforcing the reactor basemat in accordance with the dossier submitted by EDF; 3 - Germany: Judgment of the European Court of Justice on the nuclear fuel tax; 4 - India: Judgment of the High Court of Kerala in a public interest litigation challenging the constitutional validity of the Civil Liability for Nuclear Damage Act, 2010; 5 - Japan - District court decisions on lawsuits related to the restart of Sendai NPP and Takahama NPP; 6 - Poland: Decision of the Masovian Voivod concerning the legality of the resolution on holding a local referendum in the Commune of Rozan regarding a new radioactive waste repository; Certain provisions of the Regulation of the Minister of Health of 18 February 2011 on the conditions for safe use of ionising radiation for all types of medical exposure have been declared unconstitutional by a judgment pronounced by the Constitutional Tribunal; 7 - Slovak Republic: Developments in relation to the disclosure of information concerning the Mochovce nuclear power plant

  12. Interface Analyses Between a Case-Hardened Ingot Casting Steel and Carbon-Containing and Carbon-Free Refractories

    Science.gov (United States)

    Fruhstorfer, Jens; Dudczig, Steffen; Rudolph, Martin; Schmidt, Gert; Brachhold, Nora; Schöttler, Leandro; Rafaja, David; Aneziris, Christos G.

    2018-06-01

    Corrosion tests of carbon-free and carbon-containing refractories were performed. The carbon-free crucibles corroded, whereas the carbon-containing crucibles were negligibly attacked. On them, inclusions were attached. This study investigates melt oxygen contents, interface properties, and steel compositions with their non-metallic inclusions in order to explore the inclusion formation and deposition mechanisms. The carbon-free crucibles were based on alumina, mullite, and zirconia- and titania-doped alumina (AZT). The carbon-containing (-C) ones were alumina-C and AZT-C. Furthermore, nanoscaled carbon and alumina additives (-n) were applied in an AZT-C-n material. In the crucibles, the case-hardened steel 17CrNiMo7-6 was remelted at 1580 °C. It was observed that the melt and steel oxygen contents were higher for the tests in the carbon-free crucibles. Into these crucibles, the deoxidizing alloying elements Mn and Si diffused. Reducing contents of deoxidizing elements resulted in higher steel oxygen levels and less inclusions, mainly of the inclusion group SiO2-core-MnS-shell (2.5 to 8 μ m). These developed from smaller SiO2 nuclei. The inclusion amount in the steel was highest after remelting in AZT-C-n for 30 minutes but decreased strongly with increasing remelting time (60 minutes) due to inclusions' deposition on the refractory surface. The Ti from the AZT and the nanoadditives supported inclusion growth and deposition. Other inclusion groups were alumina and calcium aluminate inclusions. Their contents were high after remelting in carbon- or AZT-containing crucibles but generally decreased during remelting. On the AZT-C-n crucible, a dense layer formed from vitreous compositions including Al, Ca, Mg, Si, and Ti. To summarize, for reducing forming inclusion amounts, mullite is recommended as refractory material. For capturing formed inclusions, AZT-C-n showed a high potential.

  13. CASE REPORT CASE CASE Post-traumatic cholesteatoma … a ...

    African Journals Online (AJOL)

    CASE REPORT. CASE. 46. SA JOURNAL OF RADIOLOGY • July 2008. CASE. Abstract. Temporal bone fractures and their acute complications have been well described in radiology and ENT journals; this is in contrast to ... post-traumatic cholesteatomas and made postulations on their origin. Since then, there have been ...

  14. CASE STUDY CRITIQUE; UPPER CLINCH CASE STUDY

    Science.gov (United States)

    Case study critique: Upper Clinch case study (from Research on Methods for Integrating Ecological Economics and Ecological Risk Assessment: A Trade-off Weighted Index Approach to Integrating Economics and Ecological Risk Assessment). This critique answers the questions: 1) does ...

  15. Clinical Case Registries (CCR)

    Data.gov (United States)

    Department of Veterans Affairs — The Clinical Case Registries (CCR) replaced the former Immunology Case Registry and the Hepatitis C Case Registry with local and national databases. The CCR:HIV and...

  16. Project management case studies

    CERN Document Server

    Kerzner, Harold R

    2013-01-01

    A new edition of the most popular book of project management case studies, expanded to include more than 100 cases plus a ""super case"" on the Iridium Project Case studies are an important part of project management education and training. This Fourth Edition of Harold Kerzner''s Project Management Case Studies features a number of new cases covering value measurement in project management. Also included is the well-received ""super case,"" which covers all aspects of project management and may be used as a capstone for a course. This new edition:Contains 100-plus case studies drawn from re

  17. CASING DRILLING TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Nediljka Gaurina-Međimurec

    2005-12-01

    Full Text Available Casing drilling is an alternative option to conventional drilling and uses standard oilfield casing instead of drillstring. This technology is one of the greatest developments in drilling operations. Casing drilling involves drilling and casing a well simultaneously. In casing driling process, downhole tools can be retrieved, through the casing on wire-line, meaning tool recovery or replacement of tools can take minutes versus hours under conventional methods. This process employs wireline-retrievable tools and a drill-lock assembly, permitting bit and BHA changes, coring, electrical logging and even directional or horizontal drilling. Once the casing point is reached, the casing is cemented in place without tripping pipe.

  18. Illustrative cases for monitoring by quantitative analysis of BRAF/NRAS ctDNA mutations in liquid biopsies of metastatic melanoma patients who gained clinical benefits from anti-PD1 antibody therapy.

    Science.gov (United States)

    Seremet, Teofila; Planken, Simon; Schreuer, Max; Jansen, Yanina; Delaunoy, Mélanie; El Housni, Hakim; Lienard, Danielle; Del Marmol, Véronique; Heimann, Pierre; Neyns, Bart

    2018-02-01

    Anti-programmed death 1 (PD-1) monoclonal antibodies improve the survival of metastatic melanoma patients. Predictive or monitoring biomarkers for response to this therapy could improve the clinical management of these patients. To date, no established biomarkers are available for monitoring the response to immunotherapy. Tumor- specific mutations in circulating tumor DNA (ctDNA) such as BRAF and NRAS mutations for melanoma patients have been proposed for monitoring of immunotherapy response. We present seven illustrative cases for the use of ctDNA BRAF and NRAS mutations' monitoring in plasma. The cases described exemplify four distinct clinical benefit patterns: rapid and durable complete response (CR), early progression, followed by CR, CR followed by early progression after interrupting treatment and long-term disease stabilization. These representative cases suggest that comprehensive BRAF/NRAS ctDNA monitoring during anti-PD1 therapy is informative and can be of added value for the monitoring of melanoma patients gaining clinical benefit on anti-PD1 treatment. An important advantage of our approach is that using the cartridge system on the Idylla platform for mutation analysis, the results become available the same day 2 h after plasma collection. Therefore, in the future, the ctDNA level can be an element in the clinical management of the patients.

  19. Case Study Research Methodology

    Directory of Open Access Journals (Sweden)

    Mark Widdowson

    2011-01-01

    Full Text Available Commenting on the lack of case studies published in modern psychotherapy publications, the author reviews the strengths of case study methodology and responds to common criticisms, before providing a summary of types of case studies including clinical, experimental and naturalistic. Suggestions are included for developing systematic case studies and brief descriptions are given of a range of research resources relating to outcome and process measures. Examples of a pragmatic case study design and a hermeneutic single-case efficacy design are given and the paper concludes with some ethical considerations and an exhortation to the TA community to engage more widely in case study research.

  20. Pure Case and Prepositional Case in Russian

    DEFF Research Database (Denmark)

    Durst-Andersen, Per; Lorentzen, Elena

    2017-01-01

    By considering Russian case as the nominal equivalent to mood whereby its semantic functions are emphasized at the expense of its syntactic functions, it is demonstrated that the nominative, accusative, vocative and genitive cases constitute a mini system in which the nominative and the accusative...

  1. Comparative Test Case Specification

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Heiselberg, Per

     This document includes a definition of the comparative test cases DSF200_3 and DSF200_4, which previously described in the comparative test case specification for the test cases DSF100_3 and DSF200_3 [Ref.1]....... This document includes a definition of the comparative test cases DSF200_3 and DSF200_4, which previously described in the comparative test case specification for the test cases DSF100_3 and DSF200_3 [Ref.1]....

  2. CASE REPORT Degenerative leiomyopathy CASE REPORT

    African Journals Online (AJOL)

    cases the condition was progressive and eventually affected the entire ... been discouraged because of the progressive nature of the disease. A gastrostomy and/or ... which eventually lead to their demise, usually in their late teens.4. 1.

  3. Useful Business Cases

    DEFF Research Database (Denmark)

    Nielsen, Peter Axel; Persson, John Stouby

    2017-01-01

    during implementation and value creation. This article presents lessons learned from our action research, lessons that we incorporated into a business case method and subsequently evaluated with IS managers. There are three lessons on: (1) improving the content of business cases, (2) how to develop...... research study seeks to improve the usefulness of business cases in IS projects. We used collaborative action research with Danish municipalities to improve their practices when developing and using business cases and to change their perceptions of what constitutes a good business case that is useful...... business cases, and (3) the use of business cases in subsequent value creation. These lessons summarize our findings and the contributions are that we in the business case method propose to: (1) include minimal contents, (2) develop social commitment, and (3) structure for dynamic use during value creation...

  4. PSS Case Book

    DEFF Research Database (Denmark)

    Neugebauer, Line Maria; Mougaard, Krestine; Andersen, Jakob Bejbro

    The transformation process towards a PSS-oriented company is describes, through the presentation of the best practice cases. Each case describes motivations, challenges, business models and PSS offerings....

  5. 451 Case studies Cardiac

    African Journals Online (AJOL)

    Marinda

    Case Studies. 29 ... A case of a 26-year-old ASA I physical status male undergoing septoplasty had an abrupt ... myocardial infarction, severe hypertensive crisis, cerebral .... or no formal management is required in an ASA I patient.8 One.

  6. Xeroderma pigmentosum (case report

    Directory of Open Access Journals (Sweden)

    Dubey Arvind

    1990-01-01

    Full Text Available Xeroderma pigmentosum is a rare, hereditary and fatal disease of the skin. Ocular involvement is known to occur in 80% of cases. A case with typical cutaneous and ocular lesions is reported.

  7. Mining with Rare Cases

    Science.gov (United States)

    Weiss, Gary M.

    Rare cases are often the most interesting cases. For example, in medical diagnosis one is typically interested in identifying relatively rare diseases, such as cancer, rather than more frequently occurring ones, such as the common cold. In this chapter we discuss the role of rare cases in Data Mining. Specific problems associated with mining rare cases are discussed, followed by a description of methods for addressing these problems.

  8. FHEO Filed Cases

    Data.gov (United States)

    Department of Housing and Urban Development — The dataset is a list of all the Title VIII fair housing cases filed by FHEO from 1/1/2007 - 12/31/2012 including the case number, case name, filing date, state and...

  9. Portal cholangiopathy: case report

    Directory of Open Access Journals (Sweden)

    Maria Cecilia Almeida Maia

    2014-01-01

    Full Text Available The present report describes the case of a child that after blunt abdominal trauma presented with portal thrombosis followed by progressive splenomegaly and jaundice. Ultrasonography and percutaneous cholangiography revealed biliary dilatation secondary to choledochal stenosis caused by dilated peribiliary veins, characterizing a case of portal biliopathy. The present case report is aimed at presenting an uncommon cause of this condition.

  10. Defining a periodontitis case

    DEFF Research Database (Denmark)

    Baelum, Vibeke; Lopez, Rodrigo

    2012-01-01

    . Conclusions The results indicate that it should be feasible for the periodontal community to reach an agreement over the distinction between a case and a non-case. The classification system proposed by van der Velden is better suited for providing clinicians with a clear image of the case....

  11. Development of Non-Metallic Fuel Elements for a High-Temperature Gas-Cooled Reactor; Mise au point d'elements combustibles non metalliques pour un reacteur a haute temperature, refroidi par un gaz; Razrabotka nemetallicheskikh teplovydelyashchikh ehlementov dlya vysokotemperaturnogo reaktora s gazovym okhlazhdeniem; Elementos combustibles no metalicos para un reactor de temperatura elevada refrigerado por gas

    Energy Technology Data Exchange (ETDEWEB)

    Liebmann, B.; Schafer, L.; Spener, G. [NUKEM, Nuklear-Chemie und -Metallurgie G.m.b.H., Wolfgang bei Hanau, Federal Republic of Germany (Germany)

    1963-11-15

    In connection with fuel element development work for the high-temperature gas-coolcd reactor of the Brown-Boveri/Krupp Reaktorbau G.m.b.H., two different fuel element concepts were considered and developed. In both cases the fuel element consists of a graphite ball of 6 cm in diam. which contains the fuel insert, a cylindrical pellet of about 20 mm in diam. and 16 mm in height. The two concepts differ in the type of the.fuel insert as well as in the preparation of the graphite ball. In the first concept the fuel insert consists of a mixture of UC{sub 2} and graphite which is prepared by blending U{sub 3}O{sub 8} and graphite, pressing them into pellets and reacting the two components in a vacuum furnace at 1800{sup o}C. The atomic ratio of U : C is 1:45. Since this type of fuel pellet does not retain the fission products completely the surrounding graphite sphere had to be made impervious to fission products by impregnation in order to obtain a fission-product retaining element. Permeabilities of the order of 10{sup -6}cm{sup 2}/s could be achieved. In the second concept the fuel insert consists of a solid solution of UC in ZrC and is coated with a layer of ZrC. The molar ratio of UC to ZrC is 1 : 20. The fuel pellet preparation was accomplished by the following procedure: UO{sub 2}, ZrO{sub 2}, and graphite were mixed and pressed into pellets. The pellets were reacted to the carbides. Ball milling of the carbides was followed by hot pressing at temperatures o f 2000{sup o}C. Densities of more than 95% of the theoretical density could be achieved. A full description of the preparation and of some physical properties of the fuel pellets is given in the paper. A sufficient fission gas retention behaviour of this type of fuel insert which allows it to be put into unimpregnated graphite balls is expected. Other advantages of this kind of fuel are discussed. (author) [French] Dans le cadre des etudes de combustibles destines au reacteur a haute temperature, refroidi par

  12. CASE REPORT CASE CASE Conned by Conn's syndrome

    African Journals Online (AJOL)

    2008-01-08

    Jan 8, 2008 ... ing of the aldosterone-producing adenoma (APA) can prove challenging but is nonetheless very important for surgical planning and cure. We present two patients with MRI (magnetic resonance imaging) confirma- tion of APA with negative and equivocal CT (computed tomography) scans. Case 1.

  13. Specification analysis of plutonium fuels for non-metallic impurities. I. Estimation of carbon

    Energy Technology Data Exchange (ETDEWEB)

    Rizvi, G H; Sethuraman, P R; Venkataramana, P; Natarajan, P R

    1975-01-01

    An analytical method for the estimation of carbon in plutonium samples in the range of 10-400 ..mu..g by conductometry has been developed. In the first step of the method, the entire carbon in sample is converted into CO/sub 2/ which in the second step is completely absorbed in barium hydroxide solution in conductivity of the solution.

  14. Implementation of a Non-Metallic Barrier in an Electric Motor

    Science.gov (United States)

    M'Sadoques, George A. (Inventor); Carra, Michael R. (Inventor); Beringer, Durwood M. (Inventor)

    2013-01-01

    A motor for use in a volatile environment includes a rotor exposed to the volatile environment, electronics for rotating the rotor, an impervious ceramic barrier separating the electronics and the rotor, and a flexible seal for preventing the volatile environment from contacting the electronics and for minimizing vibratory and twisting loads upon the barrier to minimize damage to the barrier.

  15. Evolution of Non-metallic Inclusions and Precipitates in Oriented Silicon Steel

    Science.gov (United States)

    Luo, Yan; Yang, Wen; Ren, Qiang; Hu, Zhiyuan; Li, Ming; Zhang, Lifeng

    2018-06-01

    The evolution of inclusions in oriented silicon steel during the manufacturing process was carried out by chemical composition analysis, non-aqueous electrolytic corrosion, and thermodynamic calculation. The morphology, composition, and size of inclusions were analyzed introducing field emission scanning electron microscope. The oxides were mainly formed during the secondary refining, and the nitrides, sulfides, and compounds were formed during the solidification and cooling of steel in the processes of continuous casting and hot rolling.

  16. To the problem of nonmetallic inclusions assimilation by slags in the course of steel casting

    International Nuclear Information System (INIS)

    Klimov, Yu.V.; Krupman, L.I.; Medzhibozhskij, M.Ya.; Povkh, Yu.I.; Belanenko, A.A.

    1975-01-01

    The effect of slag viscosity as well as a method of steel pouring with slag-forming mixtures used upon the slag assimilation of oxide inclusions has been studied with a radioactive tracer method. The inclusions are absorbed by slag primarily in the course of filling casting moulds when a relatively intensive metal circulation occurs. The ensuing decrease of slag viscosity results in better purification of steel from inclusions. In the period of natural convection the inclusions are not removed irrespective of the slag properties. The bottom pouring results in the lowest degree of steel purification from inclusions due to the limited surface of a slag-metal contact

  17. Alteration of non-metallic barriers and evolution of solution chemistry in salt formations in Germany

    International Nuclear Information System (INIS)

    Herbert, H.J.; Becker, D.; Hagemann, S.; Meyer, Th.; Noseck, U.; Rubel, A.; Mauke, R.; Wollrath, J.

    2005-01-01

    Different Engineered Barrier Systems (EBS) materials considered in Germany for the sealing of repositories in salt formations are presented. Their long term behaviour in terms of interactions with salt solutions is discussed and evaluated. The discussed EBS materials are crushed salt, self sealing salt backfill, bentonite and salt concrete. Whereas the knowledge concerning the geochemical, geomechanical, hydrological and thermal behavior of crushed salt and salt concrete is well advanced further research is needed for other EBS materials. The self healing salt backfill has also been investigated in depth recently. In order to fully qualify this material large scale in situ experiments are still needed. The present knowledge on compacted bentonites in a salt environment is not yet sufficient for reliable predictions of the long-term performance in salt formations. The sealing concept of the low- and intermediate-level Radioactive Waste Repository Morsleben (ERAM) in a former rock salt and potash mine is presented. This concept is based on cementitious materials, i.e. salt concrete. The geochemical stability of different salt concretes in contact with brines expected in ERAM is addressed. It is shown how the results from leaching experiments and geochemical modelling are used in the safety analyses and how the chemical boundary conditions prevailing in the EBS influence the development of the permeability of the sealing system and thus control the radionuclide release. As a result of modelling the behaviour of the seals in the safety assessment it is shown, that the seals are corroded within a time span of about 20 000 years. The influence of the uncertainty in the model parameters on the safety of the repository was assessed by a variation of the initial permeability of the seal. The maximum dose rate resulting from the radionuclide release from ERAM is nearly independent of the variation of the initial permeability within four orders of magnitude. (authors)

  18. Specification analysis of plutonium fuels for non-metallic impurities. I - estimation of carbon

    International Nuclear Information System (INIS)

    Rizvi, G.H.; Sethuraman, P.R.; Venkataramana, P.; Natarajan, P.R.

    1975-01-01

    An analytical method for the estimation of carbon in plutonium samples in the range of 10-400 μg by conductometry has been developed. In the first step of the method, the entire carbon in sample is converted into CO 2 which in the second step is completely absorbed in barium hydroxide solution in conductivity of the solution. (M.G.B.)

  19. Use of radioactive indicators for the quantitative determination of non-metall inclusions in steel

    International Nuclear Information System (INIS)

    Rewienska-Kosciuk, B.; Michalik, J.

    1979-01-01

    Methods of determining and investigating the sources of non-metal inclusions in steel are presented together with some results of radiometric investigations. The experience of several years of research in industries as well as profound studies of world literature were used as a basis for systematic and critical discussion of the methods used. Optimum methods have been chosen for the quantitative determination of oxide inclusions and for the identification of their origin (e.g. from the refractory furnace lining, the tap-hole, the runner, the ladle or mold slag). Problems of tracers (type, quantity, condition, activity), of the labelling method suitable for the various origins of inclusions, of sampling, of chemical processing of the material sampled, as well as of radiometric measuring techniques (including possible activation) are discussed. Finally, a method for the determination of inclusions resulting from the deoxidation of steel is briefly outlined. (author)

  20. Inorganic material candidates to replace a metallic or non-metallic concrete containment liner

    Energy Technology Data Exchange (ETDEWEB)

    Seni, C [Atomic Energy of Canada Ltd., Mississauga, ON (Canada); Mills, R H [Toronto Univ., ON (Canada)

    1994-12-31

    Internal liners for concrete containments are generally organic or metals. They have to be able to inhibit radioactive leakage into the environment, but both types have shortcomings. The results of research to develop a better liner are published in this paper. The best material found was fibre-reinforced mortar. Of the fibres considered, steel, kevlar and glass were the best, each showing advantages and disadvantages. 1 ref., 9 tabs., 12 figs.

  1. Thermophysical Properties of Matter - the TPRC Data Series. Volume 5. Specific Heat - Nonmetallic Solids

    Science.gov (United States)

    1970-01-01

    114 35 Lanthanum Oxide La 2O3 . . . . . . . . . . . . . . . .. . . . 118 xviii Grouping of Materials and List of Figures and Tables 2. OXIDES...triebloride hiexahyc rate (Er Cls 611 20 5 822 Freon 20 (see Chloroform) Erbium gallate (see Trierbium pentagallium dodecaoxide) Freon 21 (Cl 2CHr) 6 212...FexSe) 5 530 Kalium (see Potassium) Iron silicides: Krypton 6 34 FeSi 5 577 Lanthana (see Lanthanum oxide) Fe3Si 5 583 Lanthanum 4 110 Fe6Si3 5 580

  2. Thermophysical Properties of Matter - The TPRC Data Series. Volume 6. Specific Heat - Nonmetallic Liquids and Gases

    Science.gov (United States)

    1970-01-01

    hexahydrate (ErClj-6H201 Erbium gallate (see Trierbium p«ntagallium dodecaoxide) Trierbium pentagallium dodecaoxide lErjGajO« (Garnet) J Erbium oxide (E...Freon 22) Isotron 113 (see Freon 113) Isotron 114 (see Freon 114) J odium (see Iodine) Kalium (see Potassium) Krypton Lanthana (see Lanthanum ...oxide) Lanthanum Lanthanum oxide (LajOj) Lanthanum sesquioxide (see Lanthanum oxide) Dilantanum trioxide (see Lanthanum oxide) T auehing gas (see

  3. Treatment of transverse patellar fractures : a comparison between metallic and non-metallic implants

    NARCIS (Netherlands)

    Heusinkveld, M.H.G.; Hamer, den A.; Traa, W.A.; Oomen, P.J.A.; Maffulli, N.

    2013-01-01

    Introduction: Several methods of transverse patellar fixation have been described. This study compares the clinical outcome and the occurrence of complications of various fixation methods. Sources of data: The databases PubMed, Web of Science, Science Direct, Google Scholar and Google were searched.

  4. Nonmetallic engineered barriers, their properties and role in a geologic repository for high level radioactive waste

    International Nuclear Information System (INIS)

    Lisy, F.

    1994-01-01

    The efficiency of engineered barrier systems depends to a great extent on the properties of the materials used. Backfill and sealing materials must fulfill certain requirements and criteria. They must feature low hydraulic conductivity, high retardation capacity, extremely good sorption properties for a wide range of radionuclides potentially leachable from the deposited waste, low permeability, good compatibility with engineered and natural barriers, good workability, and availability in the necessary quantity and at a reasonable price. Some basic properties are presented of materials which fulfill, to a considerable degree, these requirements and which are thus suggested as suitable backfills, sealings of buffers, namely clay- and cement-based materials (concretes, mortars, etc.). A brief information is also given on some other materials like bitumen, asphalt, etc. (Z.S.) 4 refs

  5. Interaction of Non-Metallic Inclusion Particles with Advancing Solidification Front

    Directory of Open Access Journals (Sweden)

    Kalisz D.

    2014-06-01

    Full Text Available Praca zajmuje się zjawiskiem oddziały wania przemieszczającego frontu krystalizacji na cząstki wydzieleń niemetalicznych. Analizowano zachowanie pojedynczej cząstki wydzielenia w pobliżu poziomego i pionowego frontu. Scharakteryzowano siły działające na cząstkę w pobliżu frontu i sformułowano warunek równowagi, z którego wynika szybkość krytyczna frontu. Wyniki obliczeń zilustrowano w postaci wykresów.

  6. Ex Situ Introduction and Distribution of Nonmetallic Particles in Aluminum Melt: Modeling and Experiment

    Science.gov (United States)

    Vorozhtsov, S.; Minkov, L.; Dammer, V.; Khrustalyov, A.; Zhukov, I.; Promakhov, V.; Vorozhtsov, A.; Khmeleva, M.

    2017-12-01

    Simulation results for mechanical mixing of aluminum melt using a mixing device are presented. It is found that an increase in the rotational velocity of the vortex device leads to intensive growth of turbulent diffusion in the liquid metal. Small vortices, although energetically weaker, can provide uniform mixing, creating regions of uniformity of several tens of microns. Experimental studies showed that use of a special mechanical mixing device enables injection of course titanium diboride particles and leads to significantly improved microstructure (reduction in average grain size from 900 μm to 400 μm) and mechanical properties of aluminum alloy A356. In particular, introduction of 0.2 wt.% titanium diboride particles using the vortex device leads to an increase in yield strength (from 15 MPa to 65 MPa) and ultimate tensile strength (from 140 MPa to 220 MPa) while preserving the ductility of the alloy ( 4.5%).

  7. Thermophysical Properties of Matter - The TPRC Data Series. Volume 3. Thermal Conductivity - Nonmetallic Liquids and Gases

    Science.gov (United States)

    1970-01-01

    tivities, who compare and tabulate the results of these calculations with ISO experimental values for 70 liquids and obtain a mean difference of...1.563 0. 7748 1.297 793.2 0.7640 0.8015 1.372 0.6169 1. 606 0. 8583 1.315 291.2 0. 2280 0.7931 1.500 0. 6006 1.727 0.8547 1.446 308. 2 0. 5580 0...0. 8583 0.4396 0.1654 0.1072 1.671 1.348 0. 8960 0.4564 0,1738 0.1114 He:spectroscoplcally pure.Kr; 99-100% pure, balance xenon; thick hot

  8. Determination of nonmetallic elements in actinide complexes by oxygen flask combustion (OFC) (Part 2). Sulphur

    International Nuclear Information System (INIS)

    Ruikar, P.B.; Nagar, M.S.; Subramanian, M.S.

    1989-01-01

    This report describes the determination of sulphur in metallic complexes by oxygen flask combustion followed by conductivity titration with standard barium acetate solution in alcoholic medium and lead electrode titration using a lead ion sensitive electrode. Various organic ligands and uranyl and plutonyl synergistic complexes have been analysed by both these methods and the precision and accuracy of the results have been found to be satisfactory. (author). 12 refs., 12 tabs

  9. Electronic and thermodynamic properties of the transition between metallic and nonmetallic states in dense media

    International Nuclear Information System (INIS)

    Fortin, Xavier

    1971-01-01

    The effects of thermal excitation are introduced in the study of a simple electronic structure model for condensed media. The choice of a particle-interaction potential leads to a self-consistent calculation performed on a computer. This calculation gives a metal - nonmetal transition similar to the MOTT transition. We consider the effects of temperature and density variations upon this transition. It is possible to make use of this electronic structure to obtain the thermodynamic properties near the transition: pressure, free energy, sound velocity. The numerical results of this simple model are satisfactory. Particularly, if a dielectric constant is taken into account, the transition temperature and density are of the same order of magnitude as those observed experimentally in semiconductors. (author) [fr

  10. A study on the preparation of value-added products from the nonmetallic minerals

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    This report consists of 2 subjects. 1) A study on manufacturing technology of materials for fine chemical industry use (muscovite, sericite): For the technical development on utilization of unused mineral resources, the study was carried out on the highly purification and mineral processing of domestic sericite and muscovite. This study was also carried out to make the functional materials for the use of fine chemical industry. Scope and content of study is the high purification and the surface treatment of fine particles of sericite and muscovite. 2) Studies on manufacturing technology of materials for fine chemical and electronic industry use: Fine natural crystalline graphite which is used as a source material of a high electrically conductive film and an addition of advanced high functional solid lubricant. For use high electrically conductive film and advanced high functional solid lubricant, add new and advanced high functional properties to fine graphite powder through surface modification with gas and organic materials. (author). 71 refs., 45 tabs., 84 figs.

  11. LCAO fitting of positron 2D-ACAR momentum densities of non-metallic solids

    International Nuclear Information System (INIS)

    Chiba, T.

    2001-01-01

    We present a least-squares fitting method to fit and analyze momentum densities obtained by 2D-ACAR. The method uses an LCAO-MO as a fitting basis and thus is applicable to non-metals. Here we illustrate the method by taking MgO as an example. (orig.)

  12. LCAO fitting of positron 2D-ACAR momentum densities of non-metallic solids

    Energy Technology Data Exchange (ETDEWEB)

    Chiba, T. [National Inst. for Research in Inorganic Materials, Tsukuba, Ibaraki (Japan)

    2001-07-01

    We present a least-squares fitting method to fit and analyze momentum densities obtained by 2D-ACAR. The method uses an LCAO-MO as a fitting basis and thus is applicable to non-metals. Here we illustrate the method by taking MgO as an example. (orig.)

  13. High-frequency electro-thermal processing of secondary nonmetallic raw materials

    Directory of Open Access Journals (Sweden)

    A. V. Livshits

    2014-01-01

    Full Text Available Despite a large number of studies in industrial waste processing, this field is still a challenge. In this regard, new processing capabilities emerging from the use of high frequency (RF and microwave (MW heat equipment are a positive factor to be researched.In HF and MW processing the heating process is determined by absorption of electromagnetic wave power through the processed material. This electromagnetic wave power is transmitted by the substance atoms and spent for heating a sample, polarization, and initiation of chemical reactions. The non-conductor (dielectric and semiconductor material heat is explained by the existing effect of dielectric losses due to losses caused by the through electrical conductivity and slow processes of polarization. The dielectric losses due to electrical conductivity result from the Joule heat released when through-current flows through the dielectric.The differences in frequency radiation of HF and microwave equipment define their different technological capabilities. HF-radiation represents almost homogeneous field between the plates of a running capacitor. With multiple reflection from the chamber walls MW-radiation is randomly distributed within the chamber. Thus, radiation partly returns to the generator, thereby affecting the equipment performance capability and life time. Microwave heating is uneven. The depth of penetration into the material is much less to HF-processing. HF heating features are high penetration of radiation and uniform heating of the material. Together with pre-pressing it can afford an opportunity to join the non-standard pieces of plastic to have the larger insulating items.The fact of the selective effect on the material is positive when processing the waste. Since the tangent of angle of dielectric losses of materials such as wood is directly proportional to humidity, the heating automatically stops as wood dries. This fact was used to produce for the fuel briquettes, which were modified by waste of polyethylene. Using the authors’ snap enables producing the sawdust briquettes with enhanced heat of combustion.Using the waste of pulp and paper industry was successful in creating the arrays of hydrolytic lignin for their use as a fuel or an insulation material. The presence of temperature gradient contributed to the mass-transfer of low boiling and water-soluble compounds to the sample surface, and, thus, to its hardening. The thermal insulation properties of produced material are higher than those of wood, claydite-concrete, etc. thereby making it advanced for further research.The article draws a conclusion from the theoretical and experimental studies that the use of НF power for of waste processing has unconditional prospects.

  14. Metallic and Non-Metallic Materials for the Primary Support Structure

    International Nuclear Information System (INIS)

    RA Wolf; RP Corson

    2006-01-01

    The primary support structure (PSS) is required for mechanical support of reactor module (RM) components and mounting of the RM to the spacecraft. The PSS would provide support and accept all loads associated with dynamic (e. g., launch and maneuvering) or thermally induced loading. Prior to termination of NRPCT involvement in Project Prometheus, the NRPCT Mechanical Systems team developed preliminary finite element models to gain a basic understanding of the behavior of the structure, but optimization of the models, specification of the final design, and materials selection were not completed. The Space Plant Materials team had evaluated several materials for potential use in the primary support structure, namely titanium alloys, beryllium, aluminum alloys and carbon-carbon composites. The feasibility of application of each material system was compared based on mass, stiffness, thermal expansion, and ease of fabrication. Due to insufficient data on environmental factors, such as temperatures and radiation, and limited modeling support, a final materials selection was not made

  15. Influence of non-metallic second phases on fatigue behaviour of high strength steel components

    International Nuclear Information System (INIS)

    Gonzalez, L.; Elvira, R.; Garcia de Andoin, A.; Pizarro, R.; Bertrand, C.

    2005-01-01

    To assess the real effect of the inclusion type on fatigue life of ultra clean high strength steels mechanical components made of 100Cr6 steel were fatigue tested and fracture surfaces analysed to determine the origin of fatigue cracks.Two heats proceedings from different steelmaking routes were taken for the tests. The material were forged into ring shape components which were fatigue tested under compression-compression loads. Failures were analysed by SFEM (Scanning field Emission Microscopy), proving that most of failures at high loads were originated by manganese sulphides of small size (10-70 micros), while less than 40% of all fatigue cracks due to inclusions were caused by titanium carbonitrides and hard oxides. It has been demonstrated that once number and size of hard inclusions have been reduced, the hazardous effect of oxides and carbonitrides on the fatigue life decreases also. However, softer inclusions as manganese sulphides, currently considered as less hazardous, play a more relevant role as direct cause of fatigue failure and they should be taken into account in a deeper way in order to balance both machinability and fatigue life requirements in high strength steel components. (Author) 11 refs

  16. Inorganic material candidates to replace a metallic or non-metallic concrete containment liner

    International Nuclear Information System (INIS)

    Seni, C.; Mills, R.H.

    1994-01-01

    Internal liners for concrete containments are generally organic or metals. They have to be able to inhibit radioactive leakage into the environment, but both types have shortcomings. The results of research to develop a better liner are published in this paper. The best material found was fibre-reinforced mortar. Of the fibres considered, steel, kevlar and glass were the best, each showing advantages and disadvantages. 1 ref., 9 tabs., 12 figs

  17. Thermophysical Properties of Matter - The TPRC Data Series. Volume 2. Thermal Conductivity - Nonmetallic Solids

    Science.gov (United States)

    1971-01-01

    Rept. NYO-6451, 1-16, 1955. [AD 80 699] Ratcliffe, E.H.. Phys. and Chem. of Glasses, 1.(3), 103-4, 1960. Sujak, B. , ACTA Physica Polonica , 20(2...1954. Boundary Resistance 61. Casimir, H. B. G., "Note on the Conduction of Heat in Crystals," Physica , 5(6), 495-500, 1938. 62. Berman, R., Simon...TP! r, f Theory, Estimation, and Measurement 39« Liquids by a Nonstationary Method." Physica , 19(3) 208-16, 1953. 429. Hooper, F. C. and

  18. Feasibility investigation of non-metallic and light weight metallic materials for light weight compressor pistons

    NARCIS (Netherlands)

    Wentzel, C.M.; Bergsma, O.K.; Eijk, A.

    2014-01-01

    Steel and aluminium have been the traditional materials of choice for pistons. In order to reduce moving mass-related vibrational problems, a feasibility assessment is made of the application of other materials in a project for the research group of the EFRC. In particular, polymer and metal matrix

  19. Using nonmetallic supersolid materials for manufacture for machine details and technological instrument

    International Nuclear Information System (INIS)

    Polukhin, V.P.; Voron'ko, Yu.K.; Anikeev, E.F.; Nikolaev, V.A.; Lomonova, E.E.

    1995-01-01

    A mew, method of synthesizing stabilized zirconium dioxide monocrystals from melts has been developed at the Institute of general physics under Russian Academy of Sciences. It is shown that the monocrystals prepared feature increased strength and fracture toughness; increased resistance to the action of acids, alkalis, steam; a low coefficient of friction; a high abrasive wear resistance; high mechanical characteristics at increased temperatures (up to 1400 deg C)

  20. Thermophysical Properties of Matter - The TPRC Data Series. Volume 8. Thermal Radiative Properties - Nonmetallic Solids

    Science.gov (United States)

    1972-01-01

    Iron oxldes- kaolin -aagneslum oxides- manganese oxldes-marble-nlckel oxldes-obsldlan-opal-opal glass-plexlglas- mylar—polyethylene-pyrocerams—quarts...34Dielectric Dispersion of Some Perovskite Zirconates," Phys. Rev. , A138(5), 1537-8, 1965. Loferski, J. J., "Infra-Red Optical Properties of Single...1), 131-40, 1967. Perry, C. H., "Far-Infrared Reflectance Spectra and Dielectric Dispersion of a Variety of Materials Having the Perovskite and

  1. Non-metallic dopant modulation of conductivity in substoichiometric tantalum pentoxide: A first-principles study

    Science.gov (United States)

    Bondi, Robert J.; Fox, Brian P.; Marinella, Matthew J.

    2017-06-01

    We apply density-functional theory calculations to predict dopant modulation of electrical conductivity (σo) for seven dopants (C, Si, Ge, H, F, N, and B) sampled at 18 quantum molecular dynamics configurations of five independent insertion sites into two (high/low) baseline references of σo in amorphous Ta2O5, where each reference contains a single, neutral O vacancy center (VO0). From this statistical population (n = 1260), we analyze defect levels, physical structure, and valence charge distributions to characterize nanoscale modification of the atomistic structure in local dopant neighborhoods. C is the most effective dopant at lowering Ta2Ox σo, while also exhibiting an amphoteric doping behavior by either donating or accepting charge depending on the host oxide matrix. Both B and F robustly increase Ta2Ox σo, although F does so through elimination of Ta high charge outliers, while B insertion conversely creates high charge O outliers through favorable BO3 group formation, especially in the low σo reference. While N applications to dope and passivate oxides are prevalent, we found that N exacerbates the stochasticity of σo we sought to mitigate; sensitivity to the N insertion site and some propensity to form N-O bond chemistries appear responsible. We use direct first-principles predictions of σo to explore feasible Ta2O5 dopants to engineer improved oxides with lower variance and greater repeatability to advance the manufacturability of resistive memory technologies.

  2. Evidence for the direct ejection of clusters from non-metallic solids during laser vaporization

    International Nuclear Information System (INIS)

    Bloomfield, L.A.; Yang, Y.A.; Xia, P.; Junkin, A.L.

    1991-01-01

    This paper reports on the formation of molecular scale particles or clusters of alkali halides and semiconductors during laser vaporization of solids. By measuring the abundances of cluster ions produced in several different source configurations, the authors have determined that clusters are ejected directly from the source sample and do not need to grow from atomic or molecular vapor. Using samples of mixed alkali halide powders, the authors have found that unalloyed clusters are easily produced in a source that prevents growth from occurring after the clusters leave the sample surface. However, melting the sample or encouraging growth after vaporization lead to the production of alloyed cluster species. The sizes of the ejected clusters are initially random, but the population spectrum quickly becomes structured as hot, unstable-sized clusters decay into smaller particles. In carbon, large clusters with odd number of atoms decay almost immediately. The hot even clusters also decay, but much more slowly. The longest lived clusters are the magic C 50 and C 60 fullerenes. The mass spectrum of large carbon clusters evolves in time from structureless, to only the even clusters, to primarily C 50 and C 60 . If cluster growth is encouraged, the odd clusters reappear and the population spectrum again becomes relatively structureless

  3. Tritium diffusion in nonmetallic solids of interest for fusion reactors. Final report

    International Nuclear Information System (INIS)

    Elleman, T.

    1979-01-01

    Tritium diffusion measurements have been conducted in Al 2 O 3 , BeO, Y 2 O 3 , SiC, B 4 C, Si 3 N 4 and pyrolytic carbon as a basis for evaluating these materials as potential tritium barriers in fusion reactors. Deuterium solubility measurements were conducted with Al 2 O 3 , SiC and pyrolytic carbon to establish the pressure and temperature dependence of solubility and to identify solubility ranges. Hydrogen permeability measurements on commercially available Al 2 O 3 and SiC materials were used as a check on calculated permeabilities and to provide data on hydrogen permeation rates in polycrystalline materials. The diffusion, solubility and permeation results are presented and discussed in terms of fusion reactor applications

  4. CASE REPORT A recurrent gestational choriocarcinoma case ...

    African Journals Online (AJOL)

    Admin

    molar pregnancy (Luna Russo et al., 2015). To our knowledge recurrence resulting in rupture 14 month following a live pregnancy is an extremely rare event. Management of gestational trophoblastic disease in our setup poses multiple challenges as seen in this particular case. Serum β-HCG follow up for these patients ...

  5. From Use Cases to Activity Cases

    DEFF Research Database (Denmark)

    Bækgaard, Lars

    2005-01-01

    Use cases can be used to capture requirements and to subdivide IT-systems into functionally coherent units. Information systems are activity systems that carry out important business activities. Many systems development methods recognize activity modeling as an important development activity. Use...

  6. Teaching Case: Enterprise Architecture Specification Case Study

    Science.gov (United States)

    Steenkamp, Annette Lerine; Alawdah, Amal; Almasri, Osama; Gai, Keke; Khattab, Nidal; Swaby, Carval; Abaas, Ramy

    2013-01-01

    A graduate course in enterprise architecture had a team project component in which a real-world business case, provided by an industry sponsor, formed the basis of the project charter and the architecture statement of work. The paper aims to share the team project experience on developing the architecture specifications based on the business case…

  7. Case-based reasoning

    CERN Document Server

    Kolodner, Janet

    1993-01-01

    Case-based reasoning is one of the fastest growing areas in the field of knowledge-based systems and this book, authored by a leader in the field, is the first comprehensive text on the subject. Case-based reasoning systems are systems that store information about situations in their memory. As new problems arise, similar situations are searched out to help solve these problems. Problems are understood and inferences are made by finding the closest cases in memory, comparing and contrasting the problem with those cases, making inferences based on those comparisons, and asking questions whe

  8. [Case and studies].

    Science.gov (United States)

    Schubert, András

    2015-11-15

    Case studies and case reports form an important and ever growing part of scientific and scholarly literature. The paper deals with the share and citation rate of these publication types on different fields of research. In general, evidence seems to support the opinion that an excessive number of such publications may negatively influence the impact factor of the journal. In the literature of scientometrics, case studies (at least the presence of the term "case study" in the titles of the papers) have a moderate share, but their citation rate is practically equal to that of other publication types.

  9. "Tuberculosis Case Management" Training.

    Science.gov (United States)

    Knebel, Elisa; Kolodner, Jennifer

    2001-01-01

    The need to isolated health providers with critical knowledge in tuberculosis (TB) case management prompted the development of "Tuberculosis Case Management" CD-ROM. Features include "Learning Center,""Examination Room," and "Library." The combination of audio, video, and graphics allows participants to…

  10. The Legal Case

    NARCIS (Netherlands)

    Sartor, Giovanni; Contissa, Giuseppe; Schebesta, H.; Laukyte, Migle; Lanzi, Paola; Marti, Patrizia; Paola, Tomasello

    2013-01-01

    This paper presents the first release of the Legal Case, recently developed by the ALIAS Project and still under refinement. The Legal Case is a methodological tool intended to address liability issues of automated ATM systems: it provides for a legal risk management process that can be applied

  11. A case of pancreatolithiasis

    International Nuclear Information System (INIS)

    Sasaki, Fumio; Koga, Sukehiko; Takeuchi, Akira

    1982-01-01

    During 3-year follow-up of a case of pancreatolithiasis localized in the pancreatic head, CT showed sudden new appearance of calculi over an extensive area of the body and tail of the pancreas after acute exacerbation of chronic pancreatitis. This case and the etiology and mechanism of pancreatolithiasis were discussed on the basis of literature. (Chiba, N.)

  12. Essential trichomegaly: case report

    Directory of Open Access Journals (Sweden)

    Julia Dutra Rossetto

    2013-02-01

    Full Text Available The present study reports two cases of symptomatic essential trichomegaly. Trichomegaly may develop in various diseases, including anorexia nervosa, hypothyroidism, pregnancy, pretibial myxedema, systemic lupus erythematosus, vernal keratoconjunctivitis, and uveitis. The exact incidence trichomegaly is unknown, and the condition remains sporadically reported. Two cases of symptomatic trichomegaly without any associated systemic disorder are presented in this paper.

  13. Political Psychopathy : Fujimori case

    OpenAIRE

    Nizama Valladolid, Martin

    2014-01-01

    Seven years after his political fall, Alberto Fujimori Fujimori was extradited from Chile on September 22 of 2007, in order to judge him by two cases of human rights violations and five corruption cases. The mega-trial begun on december 10 of 2007. According to the mediate authorship theory, having led the command in charge of the counterterrorist actions involves him in crimes related to human rights. The Supreme court special penal division judges him by six cases related to human rights, c...

  14. Some of the cases

    DEFF Research Database (Denmark)

    Eller, Nanna Hurwitz; Mogensen, Jørn Thykjær; Gyntelberg, Finn

    2014-01-01

    Some of the cases of acknowledged occupational psychiatric disorder in Denmark have been exposed to negative press coverage. Such individuals might have been exposed to violence to a lower extent than other with an acknowledged psychological work injury. We compared 25 cases with 35 controls...... matched on age and gender. The cases had experienced significantly fewer incidents of violence and had less anxiety and flashback symptoms than the controls. The results suggest that the negative press coverage was the reason for the psychiatric symptoms rather than exposures at the workplace....

  15. Recent Case Law

    DEFF Research Database (Denmark)

    Petz, Thomas; Sagaert, Vincent; Østergaard, Kim

    2004-01-01

    In this section authors from various European countries report the recent case law in their country on the field of private patrimonial law, that is decisions on the law of property, juridical acts, the law of obligations, contract law and prescription. The European Review of Private Law (ERPL......) started this section in 2003. The section aims to give our readers an overview of what is happening in the most recent European case law. We have asked the national reporters to report the juridical essence of the decisions given by the highest courts in their country. These national reports...... not relate the facts of the decision, nor the personal opinion of the reporter. One can find discussions on the most important decisions of European courts in ERPL’s case note section. The recent case law section gives overviews of decisions published in periods of four months. The period of January...

  16. Multiple meningiomas CASE SERIES

    African Journals Online (AJOL)

    masses in the right parietal and parasagittal region (Figs 1a and b). Case 2: A ... scan showed hyperdense parasagittal and left cerebellopontine angle meningiomas (Figs ... Meningiomas are the most common primary non-glial brain tumours.

  17. Septic Systems Case Studies

    Science.gov (United States)

    A collection of septic systems case studies to help community planners, elected officials, health department staff, state officials, and interested citizens explore alternatives for managing their decentralized wastewater treatment systems.

  18. SPOROTRICHOSIS: A CASE REPORT

    OpenAIRE

    Sudheer; Venkatakrishna; Nagaswetha; Manmohan

    2015-01-01

    Sporotrichosis is a rare disease in the Southern part of India. A sporadic case of sporotrichosis restricted to primary site of inoculation in a 11-years old student from a non–endemic region of Telangana has been described.

  19. USCIS My Case Status

    Data.gov (United States)

    Department of Homeland Security — USCIS provide a way for the public who applied for U.S. citizenship to check the status of their application online. To view the status of a case, the application...

  20. 425 Case study

    African Journals Online (AJOL)

    Marinda

    Anaesthesia management of acute aortic dissection type B in ... of a severe, constant abdominal and chest pain radiating to the ... Continuous spinal anaesthesia was induced ... these cases surgical intervention is critical.1,2 Type B of AAD is.