  1. Clinical experience with a non-ionic contrast medium (ultravist) in left ventriculography

    International Nuclear Information System (INIS)

    Lee, Ghi Jai; Park, Jae Hyung; Soe, Gwy Suk; Hong, Ju Hee; Han, Man Chung

    1988-01-01

    Non-ionic contrast medium, iopromide (Ultravist), was compared with ionic contrast medium, ioxitalamate (Telebrix), for efficacy and safety in 63 patients undergoing left ventriculography. In all patients, adverse symptoms and signs including pain, heat sense, nausea, vomiting, etc., were checked during and shortly after the injection. Blood pressure, heart rate, EKG and left ventricular pressure were also monitored during the study, and CBC, UA, BUN and creatinine were checked before and 24 hours after the study. The cineangiographic films were analysed and compared by 2 radiologists for the quality. Serious adverse effect did not occur in any case. Minor effects, especially nausea, were lee frequently caused by non-ionic contrast medium than by ionic contrast medium, and heat sense to non-ionic contrast medium was less severe than to ionic contrast medium. Except slightly elevated LVEDP at 1,5 minutes after the study in patients given ionic contrast medium, there was no significant change of electrophysiologic parameters and laboratory findings in both groups. In regard to image quality, there was no significant difference between ionic and non-ionic contrast medium. Thus non-ionic contrast medium, iopromide, appears to be safer for use in left ventriculography than the conventional ionic contrast medium, particularly in those patients at high risk of adverse effects.

  2. Arterial and venous blood pressure and blood flow following femoral angiography with a new non-ionic contrast medium

    International Nuclear Information System (INIS)

    Nyman, U.; Almen, T.

    1978-01-01

    At femoral angiography in dogs the effects of a new non-ionic contrast medium (C29) were compared with those of one non-ionic medium (metrizamide) and one ionic medium (meglumine/sodium diatrizoate) in current use. In the leg subjected to angiography the pressure gradient over the peripheral vessels decreased and the femoral blood flow increased. The changes induced by the ionic medium were significantly greater than those induced by metrizamide and C29, whereas no significant difference between the two non-ionic media was recorded. (Auth.)

  3. Ionic and non-ionic contrast media used for contrast-enhanced computed tomography in experimental pancreatitis

    International Nuclear Information System (INIS)

    Kivisaari, L.; Nuutinen, P.; Lehtola, A.; Saari, A.; Pitkaeranta, P.; Standertskjoeld-Nordenstam, C.G.; Lempinen, M.; Schroeder, T.; Helsinki Univ. Central Hospital

    1988-01-01

    Contrast enhancement of the pancreas was studied in pigs using dynamic computed tomography in experimental oedematous and haemorrhagic/necrotizing pancreatitis during the first two minutes after injection of an intravenous bolus of non-ionic contrast medium (iohexol). The prospects of separating the two forms of the disease, known to be possible with ionic contrast media, were tested with a non-ionic contrast medium. In the oedematous form, contrast enhancement after 5 hours of the disease was significantly higher than in the haemorrhagic/necrotizing form. Contrast enhancement after 30 hours of disease tended to vary with the severity of the disease, showing that the course of oedematous pancreatitis is dynamic. Intermediate forms occur and follow-up studies are needed during the disease. A non-ionic contrast medium proved as good for separating the two forms of the disease in the early phase as were ionic contrast media. In severely ill patients, non-ionic contrast media should therefore be used. (orig.)

  4. Transient partial amnesia complicating cardiac and peripheral arteriography with nonionic contrast medium

    International Nuclear Information System (INIS)

    Yildiz, A.; Yencilek, E.; Apaydin, F.D.; Duce, M.N.; Oezer, C.; Atalay, A.

    2003-01-01

    The aim of this study was to present a case of disruption of the blood-brain barrier during the coronary and lower extremity angiographies with radiological and clinical findings. This condition was secondary to intraarterial use of a nonionic, monomeric contrast medium. A total of 450 cc contrast media was used. Computed tomography examination showed contrast enhancement of the right occipital and frontoparietal cortical regions, which returned to normal one day after. The patient also fully recovered from the neurological symptoms within 24 h. We discussed the possible mechanism for blood-brain barrier disruption in this case. (orig.)

  5. Transient partial amnesia complicating cardiac and peripheral arteriography with nonionic contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Yildiz, A.; Yencilek, E.; Apaydin, F.D.; Duce, M.N.; Oezer, C. [Dept. of Radiology, Mersin Ueniv. Tip Fakueltesi Sokak Mersin (Turkey); Atalay, A. [Dept. of Cardiology, Mersin Ueniv. Tip Fakueltesi Sokak Mersin (Turkey)

    2003-12-01

    The aim of this study was to present a case of disruption of the blood-brain barrier during the coronary and lower extremity angiographies with radiological and clinical findings. This condition was secondary to intraarterial use of a nonionic, monomeric contrast medium. A total of 450 cc contrast media was used. Computed tomography examination showed contrast enhancement of the right occipital and frontoparietal cortical regions, which returned to normal one day after. The patient also fully recovered from the neurological symptoms within 24 h. We discussed the possible mechanism for blood-brain barrier disruption in this case. (orig.)

  6. Human pharmacokinetics of iohexol. A new nonionic contrast medium

    International Nuclear Information System (INIS)

    Olsson, B.; Aulie, A.; Sveen, K.; Andrew, E.

    1983-01-01

    The pharmacokinetics of iohexol, a new nonionic, water-soluble contrast medium, have been determined after intravenous injection in 20 healthy volunteers, at four different dose levels (125-500 mg I/kg). The apparent volume of distribution was 0.27 1/kg, indicating distribution in the extracellular water. The biologic half-life was 121 minutes, comparable with that of other intravascular contrast media. Iohexol was excreted completely unmetabolized in the urine, with a 100% recovery 24 hours after injection. A comparison of iohexol and chromium-51 ( 51 Cr)-EDTA clearances indicates that iohexol is mainly excreted by glomerular filtration. The 51 Cr-EDTA clearance was the same when injected separately and concomitantly with iohexol, indicating that glomerular filtration rate is not affected by iohexol. No dose dependency was observed in the investigated parameters t1/2 alpha, t1/2 beta, Vd, ClT or ClR. Iohexol pharmacokinetics are in correspondence with previously reported data on intravascular contrast media

  7. Long-term results with a nonionic contrast medium - a clinical experience report

    International Nuclear Information System (INIS)

    Hruby, W.; Stellamor, K.

    1987-01-01

    Between January 1982 and May 1986 more than 50 000 patients were examined radioligically with water-soluble (ionic and nonionic) contrast media at the Department of Radiology Rudolfstiftung, Vienna. 1983 only 2,2% of the contrast agents used were nonionic, in 1985 the share had increased to 53,3%. During this period the rate of drug-related side effects (DRSE) decreased from 6,9% (1983) to 3,3% (1985). From 1983 to 1985 DRSE were observed with 1952 patients after administration of ionic agents, whereas after application of nonionic media adverse reactions occurred in only 6 cases, so that DRSE rates of 6,98% respectively 0,07% resulted for ionic respectively nonionic contrast media. These results are discussed with regard to the physicochemical properties and physiological actions of ionic and nonionic contrast agents. (orig.) [de

  8. Renal clearance of an ionic high-osmolar and a nonionic low-osmolar contrast medium

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Vestergaard, A.; Nielsen, S.L.; Fogh-Andersen, N.; Golman, K.; Dorph, S.

    1991-01-01

    One hundred patients with normal serum creatinine concentration underwent intravenous urography with either an ionic high-osmolar (diatrizoate) or a nonionic low-osmolar (iopamidol) contrast medium after randomization. Before injection of the contrast medium, a blood sample was drawn for determinating serum creatinine concentration, and a urine sample for measurement of urine osmolality. Using x-ray fluorescence, the plasma concentration of iodine (contrast medium) was determined on blood samples drawn approximately 3 and 4 hours after injection of the contrast medium. The glomerular filtration rate was calculated by two different formulas: one requiring only a single sample and one requiring at least two samples (standard). There were poor correlations between the standard contrast medium clearance and the serum creatinine concentration, the estimated creatinine clearance (calculated from a nomogram), as well as the urine osmolality. The 3-hour and the 4-hour single-sample values correlated well with the two-sample values for both contrast media. In patients with normal serum creatinine, the glomerular filtration rate determined by measuring the contrast medium concentration in a single plasma sample obtained at 3 hours, is almost identical to the value determined from two samples. Consequently, two samples are unnecessary

  9. Iopamidol, a new non-ionic X-ray contrast medium

    International Nuclear Information System (INIS)

    Hagen, B.

    1982-01-01

    Iopamidol, a new non-ionic, monomeric contrast medium with low osmolality has been well established in our angiographic routine procedures according to the favourable results obtained in more than 300 controlled trials. The general tolerance (demonstrated by the rate of systemic adverse reactions) of the lower concentrated solution (300 mg iodine/ml is a little bit better than that of the higher concentrated one (370 mg iodine/ml). We could demonstrate a significant difference between the two preparations related to local side effects such as pain and heat sensations. The results of 100 intraindividual double blind studies (only peripheral angiography) specially referred to local side effects showed the high significant decrease of pain and heat sensations after application of Iopamidol compared to the results gained by the ionic Ioxitalamate and Ioglicinate. There was no remarkable difference between Iopamidol and Ioxaglate which is a dimeric but likewise low osmolar substance. The role of osmolality in the generation of side effects is pointed out. In consequence the advantages of using contrast media of reducted osmolality particularly in peripheral angiography must be emphasized. (orig.)

  10. Investigation of the gastrointestinal tract by means of the first dimerous nonionic x-ray contrast medium (Iotrolan)

    International Nuclear Information System (INIS)

    Troger, J.; Wenzel-Hora, B.I.

    1987-01-01

    The risks with an ionic, water solvent highly osmotic contrast medium (CM) have now led to a monomerous, nonionic CM being used, particularly in the field of gastrointestinal investigation in newborn babies and infants. Thus side effects could be reduced and the quality of the x-rays improved. However, since the monomerous nonionic CM is still hyperosmotic with respect to blood, there is a water shift into the intestinal lumen. This can upset hydration and impair the quality of radiographs. Iotrolan is the first CM isoosmotic to the blood to be used clinically. It has proved to be superior to a monomerous nonionic CM as far as radiographic quality (density and sharpness) is concerned. Fifty-one children, aged 2 days to 19 years, were give Iotrolan. Some of these patients were compared in a double-blind study with a group of children who had been given monomerous nonionic CM. If Iotrolan was given, the good quality of the radiographs remained constant throughout the gastrointestinal tract and details were clearly discernible, even in the rectum. In addition, Iotrolan in the aboral intestinal sections leads to double-contrast pictures and thereby further increases the identifiability of details. The monomerous nonionic CM, however, showed a loss in density and above all in sharpness during its passage. Since Iotrolan is isotonic to blood, its is superior to all other water-solvent CM as far as possible side effects and radiographic quality are concerned

  11. Clinical cardiovascular experiences with iopamidol: a new non-ionic contrast medium

    International Nuclear Information System (INIS)

    Partridge, J.B.; Robinson, P.J.; Turnbull, C.M.; Stoker, J.B.; Morrison, G.W.; Boyle, R.M.

    1981-01-01

    Iopamidol, a new non-ionic water-soluble contrast medium, has been compared with standard ionic media in a number of cardiovascular applications. It is stable in aqueous solution, is much less viscous and only slightly more osmolar than metrizamide. Compared to sodium meglumine diatrizoate in a series of 40 coronary arteriograms, it produced a consistent and highly significant decrease in the incidence and severity of hypotension and bradycardia following intracoronary injection. In the same group and in 62 children undergoing ventricular or great vessel angiocardiography, a subjective assessment of patient reaction showed that iopamidol was better tolerated than the ionic medium. There was a very strong patient preference for iopamidol in a group of 10 of the adult patients who had also consented to femoral artery injections of both media. Throughout these series there was no detectable difference in arterial image quality between the media. Venous phase opacification during arterioportography was assessed in 11 cases comparing iopamidol with sodium meglumine iothalamate. No significant difference was found. We conclude that iopamidol is clearly preferable to ionic media for routine cardiovascular applications. (author)

  12. Comparison of in vitro histamine release by ionic and nonionic radiographyic contrast media

    International Nuclear Information System (INIS)

    Faraj, B.A.; Martin, L.G.

    1989-01-01

    This paper discusses a study whose results showed that in 53 hospitalized patients undergoing cardiovascular catheterization, incubation of their blood samples with varying concentrations of an ionic contrast medium (Angiovist-370, 60--631 mM) induced a significant (P < .005) amount of histamine release from whole blood (3.5%--10%), as compared with the histamine release following incubation with a nonionic contrast medium. Data suggest that the use of nonionic contrast media may induce minimal histamine release and thereby involve less patient risk from the histamine-mediated allergic and hemodynamic side effects associated with radiographic contrast media procedures

  13. Roentgen contrast medium

    International Nuclear Information System (INIS)

    Tamborski, C.

    1989-01-01

    The patent deals with a roentgen contrast medium containing a perfluorinebrominealkylether of the formula C m F 2m+1 OC n F 2n Br dispersed in water, preferentially in the presence of a non-ionic dispersing agent such as a fluorinated amidoaminoxide. 2 tabs

  14. Iomeprol: results of clinical trials in children with a new nonionic contrast medium

    International Nuclear Information System (INIS)

    Gessel, R. van; Moeller, A.; Schmiedel, E.

    1994-01-01

    A total of 438 patients (1 day - 17 years) were enrolled in open-label phase III studies with Iomeprol in the most important radiologic, urologic, and cardiologic indications. Iomeprol was tested in five concentrations ranging from isotonic solutions of 150 mg iodine/ml up to 400 mg iodine/ml. Half of the patients were younger than 3 years. Apart from the mostly slight sensations of heat, pain, and taste, the following adverse events were observed independently of a causal relationship to the test compound: vomiting (1.8%), rise in blood pressure (1.8%), and restlessness (1.1%). The respective incidence of all other adverse events was below 1%. Iomeprol is a suitable and well-tolerated nonionic contrast medium for use in pediatric examinations. (orig./MG) [de

  15. Non-ionic contrast media: are they obligatory?

    International Nuclear Information System (INIS)

    Halva, S.R.

    1993-01-01

    Author presents recommendations for nonionic contrast media application. They are more expensive but less toxic than ionic ones. In order to avoid side effects in many radiological examinations (phlebography, arteriography, coronarography, ventriculography) one should use nonionic contrast media. Another reason for application of nonionic contrast agents is young age of patient or his state of health

  16. Transient global amnesia following cerebral angiography with non-ionic contrast medium

    International Nuclear Information System (INIS)

    Schamschula, R.G.; Soo, M.Y.S.

    1994-01-01

    Transit global amnesia (TGA) is an uncommon syndrome of recent memory deficit and inability to learn new data, usually resolving within 24 hours. Two cases following use of non-ionic contrast media in cerebral angiography are presented. The neuroanatomy of memory is reviewed. Possible aetiologies of TGA in relation to cerebral angiography include ischemia (embolic, arterial spasm), epilepsy that may be primary or tumour-related and direct toxic effects of contrast media. 19 refs., 1 fig

  17. Study of the safety of a new non-ionic contrast medium, iopromide 370 in patients with chronic renal failure

    International Nuclear Information System (INIS)

    Meyrier, A.; Fernet, M.; Rainfray, M.

    1989-01-01

    Intravenous injection of iodinated contrast media usually induces modifications of renal function. Adverse effects of contrast media on renal function may affect diuresis, blood flow or glomerular filtration rate. These modifications are mainly related to osmolality but also chemotoxicity. This open study showed that after i.v. injection of a bolus of iopromide 370, a new non-ionic contrast medium, there was no untoward effect on renal function in patients with renal insufficiency. This justifies comparative studies in patients with renal impairment including elderly subjects, to confirm the tolerance of this product in high risk groups [fr

  18. Myelography in the dog with non-ionic contrast media at different iodine concentrations

    International Nuclear Information System (INIS)

    Fatone, G.; Lamagna, F.; Pasolini, M.P.; Potena, A.; Brunetti, A.

    1997-01-01

    Image quality and side effects were evaluated retrospectively in a series of 183 myelographic studies performed with two non-ionic contrast media (iohexol and iopamidol) at different concentrations. Side effects during and following the procedure were recorded. Image quality was assessed using an arbitrary scoring system and statistical analysis was performed with the cross-tabulation test (4 times 2 table) by comparing two groups receiving contrast medium at higher and lower concentrations. No significant differences in side effects were observed between the two groups but the ratings for image quality were significantly higher in the group receiving contrast medium at the higher concentration than in the group receiving the lower concentration. The results suggest that a high concentration of non-ionic contrast media can safely be used in dogs and may improve image quality

  19. Are the nonionic contrast media really safe

    International Nuclear Information System (INIS)

    Seyferth, W.; Zeitler, E.

    1987-01-01

    The authors used a wide variety of ionic and nonionic contrast media in 11,203 patient examinations (angiography, phlebography, CT). Data have been collected in prospective studies since 1982. The rate of mild side effects was reduced by a factor of 2 to 3 for all examinations when nonionic contrast media were used. Angiography may not be suitable for evaluating the safety of contrast media. Because of statistical requirements, the influence of nonionic media on the rate of severe side effects will not be known for some time. The side effects of nonionic contrast media were somewhat delayed, and differed from times reported in the literature: 29% of wide effects were noticed within 15 minutes and 71% between 25 minutes to 72 hours after the study. The final results of the study will have numerous consequences for patient treatment protocols

  20. Effect of ionic and non-ionic contrast media on whole blood viscosity, plasma viscosity and hematocrit in vitro

    International Nuclear Information System (INIS)

    Aspelin, P.

    1978-01-01

    The effect of the ionic contrast media diatrizoate, iocarmate and metrizoate and the non-ionic metrizamide on whole blood viscosity, plasma viscosity and hematocrit was investigated. All the contrast media increased whole blood and plasma viscosity and reduced the hematocrit. The whole blood viscosity increased with increasing osmolality of the contrast medium solutions, whereas the plasma viscosity increased with increasing viscosity of the contrast medium solutions. The higher the osmolality of the contrast media, the lower the hematocrit became. The normal shear-thinning (decreasing viscosity with increasing shear rate) property of blood was reduced when contrast medium was added to the blood. At 50 per cent volume ratio (contrast medium to blood), the ionic contrast media converted the blood into a shear-thickening (increasing viscosity with increasing shear rate) suspension, indicating a marked rigidification of the single red cell, while the non-ionic contrast medium still produced shear-thinning, indicating less rigidification of the red cell (p<0.01). (Auth.)

  1. Clinical trial of non-ionic contrast media -comparison of efficacy and safety between non-ionic iopromide (Ultravist) and ionic contrast media-

    International Nuclear Information System (INIS)

    Lee, Ghi Jai; Kim, Seung Hyup; Park, Jae Hyung; Chang, Kee Hyun; Han, Man Chung; Kim, Chu Wan

    1988-01-01

    Non-ionic contrast media, iopromide (Ultravist) was compared with ioxitalamate (Telebrix) and/or ioxaglate (Hexabrix) for efficacy and safety in 203 patients undergoing cardiac angiography, neurovascular angiography, peripheral and visceral angiography and intravenous pyelography. In all patients, adverse symptoms and signs including heat sense, pain, nausea, vomiting, etc. were checked during and after the injection. In addition, EKG and LV pressure were monitored during the cardiac angiography. And also CBC, UA, BUN and creatinine were checked before and 24 hours after the cardiac angiography. Serious adverse effect did not occur in any case. Minor effects, such as nausea and abdominal pain, were less frequently caused by non-ionic contrast media than by ionic contrast media, especially in cardiac angiography and intravenous pyelography. There was no significant difference between ionic and non-ionic contrast media in regard to electrophysiologic parameters such as EKG and LV pressure. In case of intravenous pyelography, nonionic contrast media seemed to be superior to ionic contrast media in image quality. It is suggested that, in spite of higher cost, non-ionic contrast media be needed for the safety and image quality, particularly in those patients at high risk of adverse effects by ionic contrast media

  2. Interactions of ionic and nonionic contrast agents with thrombolytic agents

    International Nuclear Information System (INIS)

    Fareed, J.; Moncada, R.; Scanlon, P.; Hoppensteadt, D.; Huan, X.; Walenga, J.M.

    1987-01-01

    Both the ionic and nonionic intravascular contrast media have been used before and after the administration of thrombolytic agents to evaluate clot lysis during angioplasty and the treatment of myocardial infarction. In experimental animal models, the authors found that the clot lytic efficacy of streptokinase, streptokinase-plasminogen complex, and tissue plasminogen activator (t-PA) is markedly augmented if these agents are administered within 1 hour after the angiographic producers. Furthermore, contrast agents injected after the administration of t-Pa exhibit a synergistic action. In stimulated models administration of one ionic contrast medium (Angiovist, Berlex, Wayne, NJ) and two nonionic contrast agents (Isovue-370, Squibb Diagnostics, New Brunswick, NJ; Omnipaque-350, Winthrop, NY) 15 minutes before the administration of t-PA resulted in marked enhancement of the lytic activity. Although the mechanism of this interaction is unknown at this time, it should be taken into consideration in the treatment of patients with myocardial infarction, in whom contrast agents are continually used to evaluate the therapeutic lysis. Furthermore, this interaction may be partly related to the therapeutic efficacy and/or hemorrhagic actions observed

  3. Torsten Almén (1931-2016): the father of non-ionic iodine contrast media.

    Science.gov (United States)

    Nyman, Ulf; Ekberg, Olle; Aspelin, Peter

    2016-09-01

    The Swedish radiologist Torsten Almén is the first clinical radiologist ever to have made a fundamental contribution to intravascular contrast medium design, the development of non-ionic contrast media. He became emotionally triggered by the patients' severe pain each time he injected the ionic "high-osmolar" contrast media when performing peripheral arteriographies in the early 1960s. One day he got a flash of genius that combined the observation of pain, a pathophysiological theory and how to eliminate it with suitable contrast media chemistry. After self-studies in chemistry he developed the concept of iodine contrast media not dissociating into ions in solution to reduce their osmolality and even reach plasma isotonicity. He offered several pharmaceutical companies his concept of mono- and polymeric non-ionic agents but without response, since it was considered against the chemical laws of that time. Contrast media constructed as salts and dissociating into ions in solution was regarded an absolute necessity to achieve high enough water solubility and concentration for diagnostic purposes. Finally a small Norwegian company, Nyegaard & Co., took up his idea 1968 and together they developed the essentially painless "low-osmolar" monomeric non-ionic metrizamide (Amipaque) released in 1974 and iohexol (Omipaque) in 1982 followed by the "iso-osmolar" dimeric non-ionic iodixanol (Visipaque) released in 1993. This has implied a profound paradigm shift with regard to reduction of both hypertonic and chemotoxic side effects, which have been a prerequisite for the today's widespread use of contrast medium-enhanced CT and advanced endovascular interventional techniques even in fragile patients. © The Foundation Acta Radiologica 2016.

  4. Experimental and clinical studies of non-ionic isoosmolality contrast medium (iohexol 140), 2

    International Nuclear Information System (INIS)

    Tajima, Natsuki

    1986-01-01

    Based upon the results of fundamental investigation by the author, that non-ionic isoosmolality contrast medium, iohexol 140 mgI/ml, has almost no adverse effect on the shape of erythrocyte. Intraarterial digital subtraction angiography (IADSA) was performed with this agent in clinical practice. A total number of 344 injections was performed in 100 cases, and angiographic opacifications, subjective reactions and hemodynamic alterations were analysed. The contrast opacifications were excellent or good except five injections on which angiographies were afflicted by misregistration artifact. As for adverse reactions there were only 14 cases who complained mild heat sensations, whereas no pain was experienced. The intensity of local heat sensation at peripheral arteriographies was statistically milder than that caused by diatrizoate 292 mgI/ml (p < 0.001) and iohexol 300 mgI/ml (p < 0.001). The continuous monitorings of femoral blood pressure and electrocardiogram following 16 cases of thoracic aortography, 17 abdominal aortographies and 80 peripheral arteriographies revealed that iohexol 140 mgI/ml caused significantly less effects on decrease of both systolic and diastolic blood pressure and increase of heart rate. Thus it was concluded that iohexol 140 mgI/ml was well suited for IADSA as it caused no pain, good opacification quality and minimum hemodynamic effects. (author)

  5. Activation of platelets by low-osmolar contrast media: differential effects of ionic and nonionic agents

    NARCIS (Netherlands)

    Hardeman, M. R.; Konijnenberg, A.; Sturk, A.; Reekers, J. A.

    1994-01-01

    To determine the effects of an ionic low-osmolar contrast medium (ioxaglate) and two nonionic low-osmolar contrast media (iohexol and iopamidol) on human platelet activation in vitro. Flow cytometry analysis subsequent to reaction with fluorescence-labeled monoclonal antibodies was used to detect

  6. Effects of computed tomography contrast medium factors on contrast enhancement

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi; Okuda, Itsuko

    2011-01-01

    The various nonionic iodinated contrast media used in contrast computed tomography (CT) studies differ in terms of their composition, characteristics, and iodine concentration (mgI/ml), as well as the volume injected (ml). Compared with ionic iodinated contrast media, nonionic iodinated contrast media are low-osmolar agents, with different agents having different osmotic pressures. Using a custom-made phantom incorporating a semipermeable membrane, the osmotic flow rate (hounsfield unit (HU)/s) could easily be measured based on the observed increase in CT numbers, and the relationship between the osmotic pressure and the osmotic flow rate could be obtained (r 2 =0.84). In addition, taking the effects of patient size into consideration, the levels of contrast enhancement in the abdominal aorta (AA) and inferior vena cava (IVC) were compared among four types of CT contrast medium. The results showed differences in contrast enhancement in the IVC during the equilibrium phase depending on the type of contrast medium used. It was found that the factors responsible for the differences observed in enhancement in the IVC were the osmotic flow rate and the volume of the blood flow pathways in the circulatory system. It is therefore considered that the reproducibility of contrast enhancement is likely to be reduced in the examination of parenchymal organs, in which scanning must be performed during the equilibrium phase, even if the amount of iodine injected per unit body weight (mgI/kg) is maintained at a specified level. (author)

  7. Myelography in achondroplasia: value of a lateral C1-2 puncture and non-ionic, water-soluble contrast medium

    International Nuclear Information System (INIS)

    Suss, R.A.; Udvarhelyi, G.B.; Wang, H.; Kumar, A.J.; Zinreich, S.J.; Rosenbaum, A.E.

    1983-01-01

    Because of technical difficulties and diagnostic limitations encountered with other myelographic techniques in patients with achondroplasia, the authors employed a lateral C1-2 puncture and non-ionic, water-soluble contrast medium in 18 achondroplastic patients with spinal compression (21 procedures). This technique proved most appropriate for identifying the upper limit of degenerative osteophytes causing exacerbation of congenital spinal stenosis, which is crucial in planning decompressive surgery. A potentially important additional finding was the presence of degenerative lower cervical spine disease in the majority of patients. There were no serious complications. The authors recommend this technique as safe and effective in achondroplastic patients with severe congenital spinal stenosis

  8. Renal effects of the non-ionic contrast medium iopentol after intravenous injection in healthy volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Jakobsen, J.A.; Berg, K.J.; Waaler, A.; Andrew, E. (Rikshospitalet, Oslo (Norway). Dept. of Radiology Rikshospitalet, Oslo (Norway). Renal Section Nycomed A/S, Oslo (Norway). Dept. of Clinical Research and Development)

    1990-01-01

    Renal effects of the new non-ionic contrast medium iopentol in increasing doses were assessed and compared with the effects of physiologic saline. Twenty-four healthy male volunteers, allocated to three dose groups, were given iopentol intravenously in doses of 0.3, 0.6, and 1.2 g I/kg body weight, respectively. The highest dose group was also given physiologic saline separately as a control. The diuresis increased in all groups, most in the highest dose group, and with a concomitant fall of urine osmolality and increase in osmolar clearance. A slight decrease of serum osmolality, creatinine and urea occurred at 3 hours due to hemodilution. The glomerular filtration rate was unaffected by iopentol. The urinary excretion of albumin and {beta}{sub 2}-microglobulin was unchanged. However, urinary N-acetyl-{beta}-glucosaminidase and alkaline phosphatase increased significantly, most in the highest dose group. All changes were reversible. (orig.).

  9. Intra-arterial digital subtraction portography with a blood-isotonic, non-ionic, dimeric contrast medium

    International Nuclear Information System (INIS)

    Minakuchi, Kazuo; Tamaoka, Koichi; Nishio, Hiroshi; Matsuo, Ryoichi; Takada, Keiji; Morimoto, Atsuko; Toyoshima, Masami; Murata, Katsuko; Onoyama, Yasuto

    1993-01-01

    Intra-arterial digital subtraction portography (IA-DSP) with a blood-isotonic, non-ionic, dimeric contrast medium was carried out in 27 patients with hepatocellular carcinoma. It was possible to obtain images of excellent or good quality of the portal vein and its bilateral main branches in all patients. The third-order branches of the portal vein in the right lobe could be identified in all patients, and images of excellent or good quality were obtained in a mean of 80.2% of patients. Images of third-order branches in the left lobe were of lower quality than those of third-order branches in the right lobe; in particular, images obtained were of poor quality for 27.3% of the medial branches of the left lobe. It was impossible to identify the caudal branches in almost all patients. The side effects of IA-DSP, pain and sensations of heat were very mild; only one patient complained of mild pain, while 18 patients (69.2%) complained of no sensations of heat whatsoever. (author)

  10. Survey of the pharmacology of non-ionic X-ray contrast media

    International Nuclear Information System (INIS)

    Turnheim, K.

    1986-01-01

    The non-ionic X-ray contrast media metrizamide, iopamidol, iohexol, and iopromide do not bind calcium and are less hyperosmolar than the conventional ionic contrast media, for instance amidotrizoate (diatrizoate), iothalamte, or ioglicate. Hence the use of non-ionic contrast media is associated with less undesirable side-effects that are attributable to hypertonicity such as an increase in circulating plasma volume, decreased deformability of red blood cells, damage of vascular endothelium with consequent activation of blood coagulation, the complement system and fibrinolysis, increased release of bradykinin and histamine, cardiac arrhythimas, diuresis, vasodilation and decreased blood pressure, pain and heat sensation. Because of less dilution the quality of imaging is also better. According to the intravenous LD 50 in experimental animals the acute toxicity of non-ionic contrast media is lower than that of ionic media. With respect to contrast quality and the rate of side-effects tha various non-ionic contrast media appear to be equivalent. Despite their higher price and higher viscosity it is probable that the non-ionic contrast media will replace the classical ionic media, especially in angio- and myelography. (Author)

  11. Ionic versus nonionic contrast media

    International Nuclear Information System (INIS)

    Zylak, C.J.; Gafni, A.

    1988-01-01

    The efficacy and effectiveness of the nonionic contrast media have been established. Widespread usage has been hampered because of the approximate tenfold increase in cost compared with the ionic media. An economic evaluation considering costs and consequences of both interventions (ionic vs nonionic contrast media) was performed; it is a cost effectiveness (CEA) and a cost-benefit analysis (CBA) for the Canadian experience. The results of the CEA demonstrate a value per life-year saved within an acceptable range when compared with value for quality-adjusted life years for programs such as treatment of severe (diastolic≥ 105 mm Hg) and mild (diastolic 95-104 mm Hg) hypertension in men aged 40. The CBA showed a net cost to society when benefits were measured as future treatment costs saved plus productivity gained. However, if people are willing to pay a small amount for the comfort of the new intervention, this will result in a break-even situation

  12. Should nonionic radiographic contrast media be given to all patients?

    International Nuclear Information System (INIS)

    Parfrey, P.S.; Cramer, B.C.; McManamon, P.J.

    1988-01-01

    In the 1970s about one patient of every 40,000 who underwent intravenous urography died. It has been suggested that lives can be saved by using only nonionic or low-osmolarity contrast agents. The authors suggest a multicentre double-blind randomized controlled trial of nonionic versus ionic contrast media

  13. Evaluation of clot formation in blood-contrast agent mixture: experimental study on ionic/nonionic contrast agents and plastic/ glass syringes

    International Nuclear Information System (INIS)

    Shim, Hyung Jin; Lee, Jong Beum; Lee, Yong Chul; Lee, Kwan Seh; Kim, Kun Sang

    1991-01-01

    Recent introduction of low-osmolar nonionic contrast agents has allowed the performance of angiography with certain advantages such as reduced pain, reduced osmotic load and other potential advantages, over high osmolar ionic contrast agents. But the potential thrombogenic risk of nonionic contrast agent has been debate because of their weak anticoagulation effect. Several reports have recently documented the formation of thrombi in catheters and syringes containing nonionic contrast agent, and thromboembolic episodes have been noted during angiographic procedures. We have also been experienced blood clotting within blood mixed contrast agent syringe during angiography. Thus, we have studied with blood mixed ionic (Diatrizoate, Ioglicate) agents and nonionic (Iopamidol, Iopromide) agents, that used usually in our hospital, and saline in plastic and glass syringes. Each syringes were checked the clot formation on 10,30,60,90 minutes. Total 340 samples were obtained from 8 adults before angiography. Our data showed that nonionic contrast agents had significantly lesser anticoagulation effect than ionic contrast agents (ρ < 0.0001) on Chi-square test), both in plastic and glass syringes. And formation of clotting in glass syringes were significantly greater than that in plastic syringes (ρ < 0.0001). Thus meticulous technique is required to prevent thrombosis during angiographic procedure using nonionic contrast agents

  14. Chemical data on ionizing and non-ionizing angiographic contrast materials

    International Nuclear Information System (INIS)

    Bonati, F.

    1980-01-01

    The cardiovascular effects of ionizing and non-ionizing contrast media are compared in experimental animals and in isolated heart preparations. The following parameters were recorded: peripheric arterial diastolic pressure, heart rate, duration of asystolic period, respiratory rate, contractility of the myocardium (dp/dt, LVSP, Vsub(max), EDV, ESV, SV). The observed changes are mainly due to the higher osmotic activity of the contrast media, as similar alterations were recorded after the injection of hyperosmotic glucose solution. It is concluded that administration of non-ionizing contrast media results in significantly less cardiovascular side effects. (L.E.)

  15. Liberation of plasma histamine after application of non-ionic contrast media

    International Nuclear Information System (INIS)

    Weiss, H.D.; Jansen, O.; Schallock, J.

    1989-01-01

    In 94 patients the levels of plasmahistamine have been measured after application of three non-ionic contrast media (Iopromid, Iopamidol, Iohexol) and after application of blood-isotonic saline solution. A significant liberation of histamine could be observed after administration of contrast media and also after administration of saline solution. Neither between the three nonionic contrast media nor between the contrast media and the saline solution significant differences could be measured. Administering contrast media after subsequently saline solution the levels of histamine were lower than in case of pure contrast media application. A psychogen induced histamine liberation is discussed. (orig.) [de

  16. [Diagnostic Significance of BAT in Anaphylaxis to Non-ionic Contrast Media].

    Science.gov (United States)

    Zhang, Hao-yue; Xu, Su-jun; Tang, Xiao-xian; Niu, Ji-jun; Guo, Xiang-jie; Gao, Cai-rong

    2015-06-01

    To investigate the diagnostic significance of basophil activation test (BAT) in anaphylaxis to non-ionic contrast media through testing the content of CD63, mast cell-carboxypeptidase A3 (MC-CPA3), and terminal complement complex SC5b-9 of the individuals by testing their levels in the normal immune group and the anaphylaxis groups to β-lactam drugs and non -ionic contrast media. The CD63 expression of basophilic granulocyte in blood was detected by flow cytometry. The levels of MC-CPA3 in blood serum and SC5b-9 in blood plasma were detected by ELISA. The CD63 expression of basophilic granulocyte in blood, the levels of MC-CPA3 and SC5b-9 of anaphylaxis to non-ionic contrast media and β-lactam drugs were significantly higher than that in normal immune group (P contrast media. BAT can be used to diagnose the anaphylaxis to non-ionic contrast media.

  17. Protective effects of losartan in renal dysfunction during coronary angiography and intervention caused by low osmolar non-ionic contrast media

    International Nuclear Information System (INIS)

    Chen Yueguang; Zhang Dadong; Gu Jun; Song Zhiping; Yu Qiang; Feng Xiaodi; Xiao Hongbing; Yin Guizhi; Guan Ping; Chen Chengjun; Yang Hui; Jin Xian; Dong Jian; Fan Xiaomin

    2007-01-01

    Objective: To observe the changes of renal function during simple coronary angiography (CAG)and pereutaneous coronary intervention (PCI)caused by low osmolar non-ionic contrast media and to evaluate the preventive effect of losartan on renal function(serum creatinine)in PCI. Methods: All 171 cases were divided into 3 groups, CAG negative group(N=73), PCI group (N=52)and treatment group (PCI + Losartan, N=46)according to the results given by coronary arteriography. The investigation was performed on the influences produced by the low osmolar non-ionic contrast medium(Ioversol)on renal function and minimal albumin proteinuria in the 3 groups. The minimal albumin proteinuria and renal function (serum creatinine) were tested before and 1 d, 3 d, 7 d after the procedure and followed by the comparison and evaluation of the outcoming data. Results: There were no significant changes of serum creatinine among 3 groups, but amount of minimal albumin proteinuria was increased in PCI group (P<0.05), and decreased obviously after Losartan medication (P<0.05). Conclusion: Low ormolar non-ionic contrast media produce no significant influence on renal function (serum creatinine)during CAG and/or PCI but with different degrees of increase for minimal albumin proteinuria, especially in PCI group. Losartan can decrease minimal albumin proteinuria after PCI procedure, possibly providing the prevention for contrast medium induced nephropathy. (authors)

  18. Better and safer diagnostic possibilities with non-ionic contrast media

    International Nuclear Information System (INIS)

    Dalmstrom, K.; Svinn, K.

    1991-01-01

    The synthesis of contrast media for medical radiography is followed out since their introduction in late 50's. A discussion is presented on the genesis of undesirable side effects of ionic contrast media due to the sodium and meglumine cations, the hypertonicity of the media and the iodinated molecule itself. The advantages of the new non-ionic non-dissociating low osmolar contrast media is stressed and its low chemotoxicity is explained in the light of their chemical structure. The qualities of the specific representatives of new three generations of non-ionic contrast media are analysed and compared: 1) metrizamide (Amipaque, Nycomed) - a soluble monomer; 2) iopamidol (Iopamiro, Bracco), iohexol (Omnipaque, Nycomed), iopromid (Ultravist, Schering), iopentol (Imagopaque, Nycomed), ioversol (Optiray Mallincrodt) - monomers, more tolerable and with lower toxicity; 3) ioxaglat, iotrolan and iodixanol -monoacidic dimers with lower osmolarity. Results from clinical trial and monitoring programs in large patients' groups are presented. The severity and incidence of the observed side effects in different organs and systems including the risk's groups are given. Compared to the conventional ionic media, the occurence of undesired effects has been reduced to about 1/6 with the use of the new products. The review unabiguously show the advantages of the non-ionic contrast media. 6 tabs., 2 figs., 26 refs

  19. Utility of intravenous nonionic contrast media for abdominal CT in patients with renal dysfunction

    International Nuclear Information System (INIS)

    Craig, B.M.; Alpern, M.B.; Sandler, M.A.; Pearlberg, J.L.; Swanson, D.P.

    1987-01-01

    The safety and efficacy of a nonionic contrast medium (NICM) for CT enhancements in patients with renal dysfunction were evaluated. Thirty consecutive patients referred for abdominal CT with a serum creatinine (SCr) level over 5 mg/dL or a SCr level of 2-5 mg/dL and another risk factor (e.g., diabetes, single kidney) received NICM. Each was matched with a control who received the same 150-mL bolus of a conventional medium. No adverse reactions or significant alterations in SCr values were found in the NICM patients. No significant differences between the patient groups were found in blinded subjective image quality ratings or measured attenuation values of a parenchymal organs and vascular structures (with the exception of less renal enhancement in the NICM patients, reflecting their renal dysfunction). Use of an NICM is a safe and effective method for contrast medium-enhanced CT in patients with renal dysfunction

  20. Computed tomography of kidney with diuretics. A method for avoiding artifact due to nonionic contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hiromura, Tadao; Terae, Satoshi; Takamura, Akio; Mizoe, Junetsu (Obihiro Kosei Hospital, Hokkaido (Japan)); Morita, Yutaka; Irie, Goro

    1989-07-01

    We devised a method for avoiding beam-hardening artifacts, which interfere with enhanced CT images of kidney due to nonionic contrast medium. The radiographic effect and the frequency of beam-hardening artifacts on enhanced CT of kidney were studied by prospective comparison among three groups: a group of 20 patients examined with furosemide (f-d.CT), a group of 20 patients examined without diuretics (non-d.CT) and a group of 20 patients examined after water intake (w-d.CT). In all patients of f-d.CT group, the renal parenchyma from the cortex to the papilla was almost evently enhanced, free from artifacts. The density of the renal papilla and pelvis in non-d.CT and w-d.CT groups was significantly higher than that in f-d.CT group, and artifacts were also observed in 14 (70%) of non-d.CT group and 12 (60%) of w.d.CT group, respectively. Satisfactory CT of kidney free from artifacts was obtained by f-d.CT, providing easy evaluation of renal pelvic or peripelvic lesions. In conclusion, this technique can be used in those pathologic cases of renal pelvis or peripelvic region, that are not clear on routine CT because of artifacts. (author).

  1. Comparison of CO2 DSA and conventional angiography using non-ionic contrast media in lower extremity angiography

    International Nuclear Information System (INIS)

    Kim, Jae Kyu; Park, Sung Jae; Koh, Seok Wan; Seo, Jeong Jin; Kang, Heoung Keun; Chung, Hyon De

    1994-01-01

    The purpose of this study is to compare CO 2 DSA and nonionic contrast media angiography in respect to the quality of the opacification of collaterals and incidence of side-effects in peripheral occlusive arterial disease. Sixteen patients who were suspected to have peripheral occlusive arterial disease were performed angiography with nonionic contrast media and CO 2 at the same location with the same catheter. The causes of the lesions were atherosclerosis(n=7) and Buerger's disease(n=9). CO 2 DSA was compared with nonionic contrast media angiography in respect to the quality of image in the diagnosis of the lesions, opacifications of collaterals and side-effects. In atherosclerosis; quality of the images of CO 2 DSA was same as that of nonionic contrast media angiography in 6 patients and was poor in 1 patient; opacifications of collaterals of CO 2 DSA were same as that of nonionic contrast media angiography in 5 patients and was poor in 2 patients. In Buerger's disease; quality of the images of CO 2 DSA was same as that of nonionic contrast media angiography in 2 patients and was poor in 7 patients; opacifications of collaterals of CO 2 DSA were same as that of nonionic contrast media angiography in 1 patient and was poor in 8 patients. Leg pain was the only side-effect after CO 2 injection occurring in 4 out of 16 patients. CO 2 could be used as safe contrast media in patient with risk factors for nonionic contrast media and for diagnosis of the atherosclerosis in lower extremity. For the procedures such as vascular intervention requiring large amount of contrast media CO 2 could effectively replace nonionic contrast media

  2. Effect of ionic and non-ionic contrast media on aggregation of red blood cells in vitro

    International Nuclear Information System (INIS)

    Raininko, R.; Ylinen, S.L.

    1987-01-01

    Fresh human blood without additives, and contrast medium were mixed and examined immediately by light microscopy in a non-flowing state. Sodium meglumine diatrizoate, meglumine diatrizoate, meglumine iodamide, sodium meglumine ioxaglate, iopromide, iopamidol, iohexol, and metrizamide were tested in concentrations of 300 mgI/ml. Physiologic saline and 5% glucose were used as controls. All media were tested in a randomized order with blood samples from 23 volunteers. No aggregation was detected in physiologic saline, and few rouleaux were found in ionic contrast media. Irregular red cell aggregates were found in all low-osmolal contrast media: in 17% of the specimens in ioxaglate, in 52% in metrizamide, and in 78 to 100% in other non-ionic media. Irregular aggregates were seen in all specimens with glucose. It remains to be domonstrated whether or not the irregular aggregation of human red cells in non-ionic contrast media has clinical significance. Iohexol was also tested with blood samples from several laboratory animals, but in nearly every case no aggregates were found. Results of animal experiments or tests with animal blood seem to be poorly applicable to man. (orig.)

  3. Effect of prostaglandin inhibition on the renal vascular response to ionic and non-ionic contrast media in the dog

    International Nuclear Information System (INIS)

    Lund, G.; Einzig, S.; Rysavy, J.; Salomonowitz, E.; Castaneda-Zuniga, W.; Amplatz, K.; Minnesota Univ., Minneapolis

    1984-01-01

    In an attempt to study the role of prostaglandins in the renal vascular response to contrast media in mongrel dogs, renal arterial injections of 6 ml of either the non-ionic contrast medium Iopamidol or the ionic medium diatrizoate meglumine/Na + were performed, before and after intravenous injection of a buffered solution of acetyl-salicylic acid (10 mg/kg) (ASA). Renal blood flow was recorded using non-occluding electromagnetic flow probes. The resting renal blood flow was significantly reduced after ASA. The usual biphasic response to contrast injection was observed both before and after ASA, and using either contrast medium. Analysis of the results failed to show any difference in degree of vasodilation or vasoconstriction after ASA. We conclude that prostaglandins may affect the resting level of renal blood flow but are not mediators of the instantaneous changes in response to contrast injection. (orig.)

  4. Streak artifacts on Kidney CT: Ionic vs nonionic contrast media

    International Nuclear Information System (INIS)

    Cho, Eun Ok; Kim, Won Hong; Jung, Myung Suk; Kim, Yong Hoon; Hur, Gham

    1993-01-01

    The authors reviewed findings of enhanced abdominal computed tomography (CT) scans to know the difference between a higher dose of conventional ionic contrast media(iothalamate meglumine) and a lower dose of a new, nonionic contrast material(ioversol). One hundred adult patients were divided into two groups. Each group consisted of 50 patients. Iothalamate meglumine and ioversol were intravenously administered in each group. The radio of the male to female in the former was 28:22, and the latter 29:21. We examine the degree of renal streak artifact and measure the Hounsfield number of urine in renal collecting system. There were significant differences of the degree of the streak artifact depending upon the osmolality of contrast media used and that was related with urine CT number(P value<0.005). We authors conclude that nonionic low osmolar contrast media is prone to cause streak artifacts and distortions of renal image than conventional ionic high osmolar contrast media

  5. Do nonionic contrast media reduce the health hazards of diagnostic exminations?

    International Nuclear Information System (INIS)

    Schmiedel, E.

    1989-01-01

    Statistics reveal the significantly lower rate of adverse reactions to nonionic contrast media in comparison to the conventional ionic media. The statistical data have been collected over many years of clinical experience and are verified by a great number of controlled studies. The only question that remains to be answered with certainty is whether it is possible to further reduce, by applying nonionic contrast media, the number of rare, serious adverse reactions or even lethal cases. Latest results of studies support this expectation, although currently statistical configuration cannot be presented. (orig.) [de

  6. Safety of non-ionic contrast media during renal artery stenting

    International Nuclear Information System (INIS)

    Ni Jun; Shen Weifeng; Zhang Ruiyan; Zhang Qi; Zhang Xian; Zheng Aifang

    2004-01-01

    Objective: To evaluate the safety of non-ionic contras media during interventional treatment of renal artery stenosis (RAS). Methods: Fifty four coronary artery disease patients associated with RAS (luminal narrowing > 50%) underwent renal artery stent implantation and percutaneous coronary intervention, only 10 of them with merely renoarterial stenosis undergone renal artery stent implantation. The successful rates of the procedure and complication together with the volumes of contrast media were recorded respectively. And the serum creatine before and 12 hours after the successful procedure were also measured. Results: Both rates of procedural success and complication were similar among the three groups. The serum creatine levels, 12 hours after the procedure, showed no difference in comparing with the baseline. Conclusion: Non-ionic contrast media (Iopamiro 370) could be safely used in patients with RAS. (authors)

  7. Contrast agents for cardiac angiography: effects of a nonionic agent vs. a standard ionic agent

    International Nuclear Information System (INIS)

    Bettmann, M.A.; Bourdillon, P.D.; Barry, W.H.; Brush, K.A.; Levin, D.C.

    1984-01-01

    The effects on cardiac hemodynamics and of a standard contrast agent, sodium methylglucamine diatrizoate [Renografin 76] were compared with the effects of a new nonionic agent (iohexol) in a double-blind study in 51 patietns undergoing coronary angiography and left ventriculography. No significant alteration in measured blood parameters occurred with either contrast agent. Hemodynamic changes occurred with both, but were significantly greater with the standard renografin than with the low-osmolality, nonionic iohexol. After left ventriculography, heart rate increased and peripheral arterial pressure fell with both agents, but less with iohexol. It is concluded that iohexol causes less alteration in cardiac function than does the agent currently most widely used. Nonionic contrast material is likely to improve the safety of coronary angiography, particularly in those patients at greatest risk

  8. Upper airway obstruction in infants and children: evaluation by tracheobronchography with a non-ionic contrast agent

    International Nuclear Information System (INIS)

    Lee Tain; Lee, S.K.

    1997-01-01

    The clinical benefits of tracheobronchograms using nonionic contrast medium were evaluated prospectively in ten infants and children with suspected airway obstruction who could not be weaned from endotracheal intubation and were in incubators. All patients were examined usedated. The contrast agent was injected via the intubation tube, pumped with an Ambu-bag (Manual Resuscitator, Formosa-CJ Health Business Corporation, Taiwan), and then a chest radiograph was obtained immediately in both anteroposterior and lateral views using portable equipment. Imaging results were correct in eight of ten cases as judged from bronchoscopic, surgical, and clinical data. No complications occurred during or after these examinations. This method provides an easy, safe, and helpful technique for diagnosis of the airway in nonsedated infants and children whose condition is critical. (orig.)

  9. Effects of ionic and nonionic contrast media on cardiohemodynamics and quality of radiographic image during canine angiography

    International Nuclear Information System (INIS)

    Nakamura, H.; Kurata, M.; Haruta, K.; Takeda, K.

    1994-01-01

    Cardiovascular responses and radiographic image quality during cerebral angiography, aortofemoral angiography and left ventriculography with nonionic ioxilan, iohexol or iopamidol were compared with those of ionic sodium meglumine diatrizoate in pentobarbital anesthetized dogs. Injection of all contrast media caused cardiovascular changes to a greater or lesser degree, e.g., hypotension, bradycardia, tachycardia, a decrease in left ventricular pressure (LVP) and its first derivative (dP/dt), and prolongation of the P-Q and Q-T intervals. Ionic diatrizoate had a greater effect on cardiovascular parameters than nonionic contrast media during angiography in all areas. Moreover, diatrizoate produced cardiac arrhythmias and prominent changes in blood rheology concerned with blood viscosity and deformability of the erythrocyte. The cause of various effects of contrast media seemed to lie mainly in osmolality, viscosity and partially ionic additives. The radiographic image quality of all of the contrast media used was similar, but nonionic ioxilan and iohexol with lower iodine content and low osmolality gave better radio opacity than ionic diatrizoate in cerebral angiography. These results suggested that nonionic contrast media should be recommended as a diagnostic tool for both animals and human patients in poor health

  10. Non-ionic iodinated contrast media related immediate reactions: A mechanism study of 27 patients.

    Science.gov (United States)

    Zhai, Liqin; Guo, Xiangjie; Zhang, Haoyue; Jin, Qianqian; Zeng, Qiang; Tang, Xiaoxian; Gao, Cairong

    2017-01-01

    The underlying mechanism of non-ionic iodinated contrast media-related immediate reactions was evaluated in this study. Patients presenting at least grade II immediate reactions after non-ionic iodinated contrast media injection were enrolled. Basophil activation was evaluated by flow cytometry. The plasma concentration of human terminal complement complex SC5b-9, as well as concentrations of serum chymase, tryptase, human mast cell carboxypeptidase A3, human prostaglandin D2, and total IgE were measured by enzyme-linked immunosorbent assay. The basophil activation percentage was significantly higher in the study group than in the control group (17.94±21.06% vs 3.45±1.49%). The plasma concentration of human terminal complement complex SC5b-9 and concentrations of serum chymase, human mast cell carboxypeptidase A3, prostaglandin D2, tryptase, and total IgE were also significantly increased (236.99±318.21 vs 49.70±30.41ng/mL, 0.41±0.49 vs 0.09±0.06ng/mL, 1.17±0.67 vs 0.30±0.17ng/mL, 203.52±137.27 vs 102.28±48.72pg/mL, 3.81±0.22 vs 2.70±0.16ng/mL, 102.00±51.84 vs 19.97±2.75ng/mL, respectively). Both mast cells and basophils were activated in non-ionic iodinated contrast media to mediate immediate hypersensitivity, and mast cells may be involved. Different mechanisms, including IgE-dependent, complement-dependent, and direct membrane effects, contributed to mast cell and basophil activation. Individual patients may use a single or combined mechanism involving single or combined mast cells and basophils. Immediate reactions following non-ionic iodinated contrast media injection may be a mechanically heterogenous disease. Copyright © 2016. Published by Elsevier B.V.

  11. Computed microtomography visualization and quantification of mouse ischemic brain lesion by nonionic radio contrast agents.

    Science.gov (United States)

    Dobrivojević, Marina; Bohaček, Ivan; Erjavec, Igor; Gorup, Dunja; Gajović, Srećko

    2013-02-01

    To explore the possibility of brain imaging by microcomputed tomography (microCT) using x-ray contrasting methods to visualize mouse brain ischemic lesions after middle cerebral artery occlusion (MCAO). Isolated brains were immersed in ionic or nonionic radio contrast agent (RCA) for 5 days and subsequently scanned using microCT scanner. To verify whether ex-vivo microCT brain images can be used to characterize ischemic lesions, they were compared to Nissl stained serial histological sections of the same brains. To verify if brains immersed in RCA may be used afterwards for other methods, subsequent immunofluorescent labeling with anti-NeuN was performed. Nonionic RCA showed better gray to white matter contrast in the brain, and therefore was selected for further studies. MicroCT measurement of ischemic lesion size and cerebral edema significantly correlated with the values determined by Nissl staining (ischemic lesion size: P=0.0005; cerebral edema: P=0.0002). Brain immersion in nonionic RCA did not affect subsequent immunofluorescent analysis and NeuN immunoreactivity. MicroCT method was proven to be suitable for delineation of the ischemic lesion from the non-infarcted tissue, and quantification of lesion volume and cerebral edema.

  12. Efficacy of pamiray as a nonionic intravenous contrast material; experimental study suing normal rabbits

    International Nuclear Information System (INIS)

    Lee, Joon Woo; Kim, Tae Kyoung; Kim, Seung Hyup; Kim, Hyun Beom; Kim, Se Hyung; Hwang, Sung Il; Yeon, Kyung Mo

    2000-01-01

    To evaluate the efficacy of Pamiray as an intravenous nonionic contrast material by comparing it with an established nonionic contrast material (Iopamiro). Forty adult New Zealand white rabbits weighing about 3.0 kg were used in this study. Aortography and urography (scout, 5, 15 and 30 minutes delay after injection) were performed in ten rabbits with Pamiray (370 mgI/mL) and in other ten rabbits with Iopamiro (370 mgI/mL). All twenty rabbits underwent abdominal triple-phase spiral CT before and 5 and 30 seconds after injection of the contrast material. The degree of contrast enhancement seen on aortograms and intravenous urograms was determined using a three-point scale by two radiologists, who reached a consensus. CT attenuation expressed in Hounsfield units (HU) was measured using the regions of interest (ROIs) facility in the liver, bilateral kidneys, aorta, portal vein, and inferior vena cave. The Mann-Whitney U test was used in image evaluation for intergroup comparisons. There was no significant difference between the two groups in the degree of contrast enhancement seen on aortograms. In urography, however, Iopamiro was superior to Pamiray in demonstrating calyces of the right kidney on 15-minute delay images and Pamiray was superior to Iopamiro in demonstrating the right ureter and the renal pelvis on five minute-delay images and the left ureter on 30 minutes delay (p less than 0.05). Peak enhancement of the aorta during the first phase of abdominal CT was higher in the group in which Pamiray was used. When normal rabbits were used for aortography, abdominal CT, and urography, Pamiray provided more effective contrast enhancement than a previously used nonionic contrast material, namely Iopamiro. There were, however, slight differences in the enhancement features of renal calyces and ureters seen on 5- and 15-minute urograms. (author)

  13. Comparison of soft tissue effects of conventional ionic, low osmolar ionic and nonionic iodine containing contrast material in experimental animals

    International Nuclear Information System (INIS)

    McAlister, W.H.; Kissane, J.M.

    1990-01-01

    Conventional, low osmolar, and non-ionic iodine containing contrast media and saline controls were placed in the paws, muscles, and subcutaneous tissues of Sprague-Dawley rat thighs. The paw injections were observed and photographed, while the thighs were examined histologically. Results showed that although the low osmolar and non-ionic agents did produce inflammatory reactions and focal necrosis in the soft tissues, they were much better tolerated than were the conventional ionic agents. A non-ionic or low osmolar ionic contrast agent should be strongly considered when a possibility for extravasation exists. (orig.)

  14. The value of hysterosalpingography using non-ionic contrast agent combined with low-tensive drug in diagnosis of infertility

    International Nuclear Information System (INIS)

    Deng Qiwei; Liu Xiaojun; Shi Jianfen; Jiang Guohua; Ye Jinqing; Shen Jun; Song Ting

    2009-01-01

    Objective: To analyze the value of nonionic contrast agent combined with low tensive drug in the hysterosalpingography in diagnosis of infertility. Methods: 203 patients with infertility were randomly classified into two groups. Group 1 contained 108 patients administrated intramuscularly anisodamine (654-2) 30 minutes before hysterosalpingography. 95 patients in group 2 did not use 654-2. Non-ionic contrast agent was used in all patients. The image quality and post-contrast displaying status of uterus and uterine tube between the two groups were analyzed. Results: No allergic response occurred in all patients. The image quality and post-contrast displaying status of uterus and uterine tube of group 1 were obviously superior to that of group 2 (P<0.01). Conclusion: Hysterosalpingography clearly showed lesions of uterus and uterine tube when using non-ionic contrast agent combined with low-tensive drug. It is more safety with less side effects. The contraction of uterine tube can be relieved by the low-tensive drug effectively, so as to decrease the false positive rate, raise the diagnostic accuracy, and lessen patients sufferings. It is deserved to be applied generally. (authors)

  15. Are there any differences in acute adverse reactions among five low-osmolar non-ionic iodinated contrast media?

    Energy Technology Data Exchange (ETDEWEB)

    Gomi, Tatsuya; Nagamoto, Masashi; Hasegawa, Makoto; Katoh, Asako; Sugiyama, Miki; Murata, Nozomu; Kunihiro, Toshiyuki; Kohda, Ehiichi [Toho University Ohashi Medical Centre, Department of Radiology, Tokyo (Japan)

    2010-07-15

    The differences regarding adverse reactions in different low-osmolar non-ionic contrast media had not been investigated previously. Thus, the aims of this study were to identify differences in the incidence of adverse reactions in five different low-osmolar non-ionic contrast media. We prospectively recorded all adverse events associated with five different low-osmolar non-ionic contrast media used in 8,931 consecutive patients for CT. Patients were randomly assigned to five groups: iomeprol 300 mgI/ml, iopamidol 300 mgI/ml, iohexol 300 mgI/ml, iopromide 300 mgI/ml and ioversol 320 mgI/ml. Adverse events were observed in 241 patients (2.7%). The incidence of acute adverse reactions was significantly higher in the following groups: (1) iomeprol (3.9%) and iopromide (3.5%) groups, (2) patients aged 59 years or less (4.5%) compared with those aged 60 years or over (1.9%), (3) the first period (3.5%) compared with the late period (2.3%), (4) those with a past history of adverse reactions to contrast media (11.2%), and (5) patients receiving contrast media for the first time (3.3%) compared with those had received it previously (2.0%). The incidence of acute adverse reactions may be reduced in younger patients by using iopamidol, iohexol and ioversol. (orig.)

  16. Are there any differences in acute adverse reactions among five low-osmolar non-ionic iodinated contrast media?

    International Nuclear Information System (INIS)

    Gomi, Tatsuya; Nagamoto, Masashi; Hasegawa, Makoto; Katoh, Asako; Sugiyama, Miki; Murata, Nozomu; Kunihiro, Toshiyuki; Kohda, Ehiichi

    2010-01-01

    The differences regarding adverse reactions in different low-osmolar non-ionic contrast media had not been investigated previously. Thus, the aims of this study were to identify differences in the incidence of adverse reactions in five different low-osmolar non-ionic contrast media. We prospectively recorded all adverse events associated with five different low-osmolar non-ionic contrast media used in 8,931 consecutive patients for CT. Patients were randomly assigned to five groups: iomeprol 300 mgI/ml, iopamidol 300 mgI/ml, iohexol 300 mgI/ml, iopromide 300 mgI/ml and ioversol 320 mgI/ml. Adverse events were observed in 241 patients (2.7%). The incidence of acute adverse reactions was significantly higher in the following groups: (1) iomeprol (3.9%) and iopromide (3.5%) groups, (2) patients aged 59 years or less (4.5%) compared with those aged 60 years or over (1.9%), (3) the first period (3.5%) compared with the late period (2.3%), (4) those with a past history of adverse reactions to contrast media (11.2%), and (5) patients receiving contrast media for the first time (3.3%) compared with those had received it previously (2.0%). The incidence of acute adverse reactions may be reduced in younger patients by using iopamidol, iohexol and ioversol. (orig.)

  17. Are the tolerabilities of nonionic contrast media identical? Outcome of a double-blind, randomized multicentre study with Iomeprol and lopromide

    International Nuclear Information System (INIS)

    Schmiedel, E.

    1997-01-01

    Since a larger number of nonionic contrast media is available for the radiologist, the question arises as to whether they differ in their clinical tolerability. A double-blind, randomized, two-group comparison of phase IV with Iomeprol and Iopromide was carried out at 6 hospitals involving a total of 1.200 patients with the indication for computed tomography. The contrast media doses and the flow in computed tomography of the skull, thorax, and abdomen were, depending on the centre, between 50 and 200 ml and 0.5 to 3.0 ml/s, respectively. The biostatistical evaluation of adverse events which were probably contrast medium-related produced a highly significant difference between the two contrast media in favor of Iomeprol (p=0.0005). The difference in the reactions of heat, nausea, and vomiting is of clinical relevance as such adverse events may negatively affect the examination procedure and the opacification in spiral computed tomography. (orig.) [de

  18. Contrast enhanced cartilage imaging: Comparison of ionic and non-ionic contrast agents

    International Nuclear Information System (INIS)

    Wiener, Edzard; Woertler, Klaus; Weirich, Gregor; Rummeny, Ernst J.; Settles, Marcus

    2007-01-01

    Our objective was to compare relaxation effects, dynamics and spatial distributions of ionic and non-ionic contrast agents in articular cartilage at concentrations typically used for direct MR arthrography at 1.5 T. Dynamic MR-studies over 11 h were performed in 15 bovine patella specimens. For each of the contrast agents gadopentetate dimeglumine, gadobenate dimeglumine, gadoteridol and mangafodipir trinatrium three patellae were placed in 2.5 mmol/L contrast solution. Simultaneous measurements of T 1 and T 2 were performed every 30 min using a high-spatial-resolution 'MIX'-sequence. T 1 , T 2 and ΔR 1 , ΔR 2 profile plots across cartilage thickness were calculated to demonstrate the spatial and temporal distributions. The charge is one of the main factors which controls the amount of the contrast media diffusing into intact cartilage, but independent of the charge, the spatial distribution across cartilage thickness remains highly inhomogeneous even after 11 h of diffusion. The absolute ΔR 2 -effect in cartilage is at least as large as the ΔR 1 -effect for all contrast agents. Maximum changes were 5-12 s -1 for ΔR 1 and 8-15 s -1 for ΔR 2 . This study indicates that for morphologically intact cartilage only the amount of contrast agents within cartilage is determined by the charge but not the spatial distribution across cartilage thickness. In addition, ΔR 2 can be considered for quantification of contrast agent concentrations, since it is of the same magnitude and less time consuming to measure than ΔR 1

  19. Experimental investigations on the influence of the contrast medium Iopamiro 300 mixed with vegetal mucus on the nasolacrimal system and external eye tissues

    International Nuclear Information System (INIS)

    Rubaj, B.; Koper, S.; Wolski, T.; Toczowski, J.; Wolski, J.; Langwinska-Wosko, E.

    1994-01-01

    Using low osmolality, nonionized contrast medium Iopamiro-300, Bracco mixed with the mucus prepared from the seed flax (''Linum usitatissimum, L.''), a dacryocistorhinography was performed experimentally on 8 healthy mongrel dogs. Assessing the occurrence of local and general complications was the aim of the investigation. On the basis of a radiographic examination it has been shown that the mixture of the contrast medium and seed flax mucus appeared to be a very useful compound for dacryocistorhinography, especially for the evaluation of nasolacrimal duct system course and its patency. Clinical observations and a histological examination proved that this compound of the contrast medium was well tolerated by the mucous membrane of the nasolacrimal system and the external eye tissues. (author). 21 refs, 4 figs

  20. Effects of radiographic contrast media on the serum complement system

    International Nuclear Information System (INIS)

    Tirone, P.; Boldrini, E.

    1983-01-01

    The authors explored the activation of the complement system produced by a nonionic organic iodine compound, namely iopamidol, which is proposed as a contrast medium for radiographic examination by intravenous and intra-arterial injection. The study was conducted in vitro versus established ionic contrasts (diatrizoate, iothalamate, acetrizoate) and a nonionic compound (metrizamide). The adopted experimental model was the immunohemolytic detector system, in which the immune complex consisted of goat erythrocytes sensitized with the corresponding antibody (hemolysin), and complement (C') was supplied by guinea pig serum. All the products caused complement activation. The results show that nonionic contrast media produce less activation of the complement system than the traditional ionic contrast. Thus the use of nonionic contrast for radiological procedures necessitating the introduction of contrast material into the blood compartment would imply a reduced risk of anaphylactoid reactions. (orig.)

  1. Transvenous DSA: ECG-controlled cardial effects and venous complications after pre-atrial injection of nonionic contrast media

    International Nuclear Information System (INIS)

    Arlart, I.P.; Sigel, H.

    1986-01-01

    Transvenous DSA is a diagnostic technique for ambulatory examination that is well tolerated by patients, although it is commonly known that bolus injection of contrast medium for examination of the cardiovascular system may affect the cardiovascular hemodynamic process. The prospective study described was intended to reveal in 100 patients the effects on ECG data, as well as clinical symptoms of non-tolerance of contrast medium (nonionic, with high iodine content, Iopamidol 370), applied by central pre-atrial injection. In addition, catheterization-induced complications in the venous system of the arm were studied in 130 patients. Change of heart rate was the most frequent effect observed (increase in 49% of patients pretreated with Buscopan, decrease in 36% of non-pretreated patients). The second next effects were supraventricular and ventricular ES (20%), minor prolongations of PQ and QRS intervals (14%), and ST lowering (3%), without clinical symptons. In one case, an attack of Angina pectoris was observed, another patient developed a cutane allergy. After catheterization of brachial vein, thromboses were observed in 3% of patients, as well as local inflammations in 6%, short attacks of fever in 2.3%. The complications were observed for the most part in cases where re-sterilised catheters had been used. (orig.) [de

  2. Clinical application and side effects of non-ionic, low-osmolar contrast media: Iopromide (Ultavist)

    International Nuclear Information System (INIS)

    Lee, Jong Tae; Suh, Jung Ho; Suh, Jin Suk; Lee, Yeon Hee

    1988-01-01

    Generally non-ionic, water-soluble contrast media has been known to be considerably better than the conventional ionic contrast agents, because of its physiochemical properties which are more hydrophilic, lower in osmolality than the ionic agents of equivalent iodine concentration. It means that the non-ionic agent has less side reaction and better general tolerance. Iopromide (Ultavist) is a newly developed non-ionic contrast media that is suitable for angiography. Some non-ionic contrast media such as Metrizamide and lopamidol were clinically introduced and proved tobe the most compromising agents for neuroradiographic study, but lopromide is not yet freely available in the vascular study. In order to evaluate the clinical fitness and its side effects of lopromide for angiography various type of angiography were done in 136 patients using lopromide and 51 received Diatrizoate meglumine (DTM). Similar volumes of the contrast media was administered at similar rate to both groups. The results were as the follows: 1. In celiac angiography of 31 patients with lopromide (Ultravist 370) and 18 with DTM 60, there were observed 9.7% mild pain and 25.8% mild heat sensation in lopromide. In DTM 60 mild pain was approximately 3 times more frequently observed than lopromide. Heat sensation is mild and similar in frequency of both groups. There was no clinically significant side effects related to the osmolality and its difference between two groups. 2. In peripheral angiography of 47 patients with lopromide 300 and 24 with DTM 60, there were observed 19.1% mild, 6.4 moderate in pain and 46.8% mild, 1% moderate heat sensation in lopromide. But in DTM there were 33.3% mild, 58.3% moderate and 8.3% severe pain, and also 70.8% mild and 16.7% moderate heat sensation in DTM were observed. lopromide is more advantageous and better contrast agents than the DTM for peripheral vascular study on the point of low side effect related to osmolality. 3. In renal angiography, there was no

  3. Pharmacodynamics and tolerance of X-ray contrast media

    International Nuclear Information System (INIS)

    Schmiedel, E.

    1987-01-01

    The improved tolerance of nonionic contrast media compared with conventional contrast media is mainly due to their lower osmolality and reduced allergoid potential. Tolerance advantages that have been definitely proven are, for example, low-pain contrast medium injection and superior systemic tolerance; side effects of an allergic pattern occur less often. Animals experiments have established that nonionic contrast media exercise a comparatively lower influence on the cardiovascular system. The haemodynamics of pulmonary circulation are less adversely affected on intravenous bolus injection. Reduced potential risk is to be expected especially in cardiac and bronchopulmonary high-risk patients. The reduced nephrotoxicity of nonionic contrast media was definitely established by clinical studies. Further systematic studies will however be required to provide an answer to the question whether this also entails a reduction in the incidence of renal failures induced by contrast media. (orig.) [de

  4. A survey of contrast media used in coronary angiograph

    International Nuclear Information System (INIS)

    Weikl, A.; Hubmann, M.

    1982-01-01

    In recent years, various contrast media have been developed for use in coronary angiography. These contrast media may be divided into ionic contrast media of high osmolality, those of low osmolality, and nonionic contrast materials. We conducted our own clinical studies with 40 patients. In random succession a standard contrast medium (ionic, of high osmolality) and a new-generation contrast medium (either nonionic or ionic with low osmolality) were injected into the right and left coronary arteries. After each injection we measured the systolic and diastolic blood pressure using a liquid-filled coronary catheter. In addition, the change in the length of the cardiac cycle was registered in terms of the R-R interval (in ms) and at the same time, leads I, II, and III of the ECG were recorded. We studied the influence of the various contrast media on the activity of ATPase in in vitro experiments, using Lasser and Lang's. When ionic contrast media of low osmolality and nonionic contrast media were utilized the heart rate showed no change. Disturbances of rhythm such as ventricular tachycardia or fibrillation were not observed. All of the contrast media used produced the same ECG changes. These changes can be ascribed to the inhibition of ATPase. The arterial blood pressure was lowered significantly only by ionic contrast media of high osmolality only. (orig.)

  5. Pure and diluted contrast medium in the evaluation of portal venous system with digital subtraction angiography

    International Nuclear Information System (INIS)

    Gattoni, F.; Baldini, V.; Pozzato, C.; Nessi, R.; Raiteri, R.; Uscenghi, C.; Opocher, E.; Santambrogio, R.

    1990-01-01

    We report the results of intra-arterial digital subtraction angiography (DSA) in 100 patients with portal hypertension. The portal venous system was evaluated; all patients underwent angiography of the celiac and superior mesenteric arteries before surgery. Forty-four of them were also examined after Warren splenorenal shunts. Therefore, a total of 144 exams was evaluated. The authors always employed low-osmolality ionic and non-ionic contrast media (iodine concentration: 300-350 mg/ml). In 70 cases pure contrast medium was injected (20/25 ml): in the extant 74 cases it was diluted with an equal volume of saline solution (osmolality and iodine concentration reduced by 50%). Intra-arterial DSA always visualized portal venous system, collateral circulation, shunt location and postoperative changes. The mayor advantage of intra-arterial DSA is the smaller amount of contrast medium injected, so that local and systemic side effects are rare. According to our experience, it is best to dilute the contrast medium and inject the same amount as in conventional angiography, at the same rate. Other well-known advantages of intra-arterial DSA are quicker execution, less injury to arteries using smaller caliber catheters, and low cost. The major disadvantage of intra-arterial DSA, as it appeared also in our study, is the field size of the intensifier, which in our case was limited to 6-9 inches. This is an insufficient coverage for the whole portal system to be studied, and some contrast medium injections become therefore necessary. An average of 3 injections were given to each patient. This problem reduces the advantage of less contrast medium per injection. At any rate, even though intra-arterial DSA exhibits this limitation, it can nevertheless yield important information in the pre- and postoperative evaluation of patients with portal hypertension

  6. Contrast media on abdominal computed tomography

    International Nuclear Information System (INIS)

    Skalpe, I.O.; Oestensen, H.M.

    1984-01-01

    Abdominal computed tomography was performed in 55 patients before and after intravenous injection of 60 ml of a non-ionic (iohexol) or an ionic (metrizoate) contrast medium. The adverse effects were recorded and a series of measurements of attenuation values before and after the contrast medium injection was performed in the aorta and in hepatic and renal parenchyma. Only minor adverse effects were seen with both contrast media, but iohexol was clearly better tolerated than metrizoate. No difference in the enhancement properties was found between the two contrast media. (orig.)

  7. Compatibility of epirubicin-loaded DC bead™ with different non-ionic contrast media.

    Science.gov (United States)

    Sarakbi, Iman; Krämer, Irene

    2016-12-01

    The aim of this study was to determine the compatibility of epirubicin-loaded DC bead™ with different non-ionic contrast media over a period of seven days when stored light protected under refrigerated conditions. DC bead™ (2 ml) (Biocompatibles UK Ltd) of the bead size 70-150 µm ( = DC bead M1) or bead size 100-300 µm were loaded with 75 mg epirubicin powder formulation (Farmorubicin® dissolved in 3 ml water for injection to a concentration of 25 mg/ml) or 76 mg epirubicin injection solution (Epimedac® 2 mg/ml) within 2 h or 6 h, respectively. After removal of the excess solution, the epirubicin-loaded beads were mixed in polypropylene syringes with an equal volume (∼1.5 ml) of contrast media, i.e. Accupaque™ 300 (Nycomed Inc.), Imeron® 300 (Bracco S.p.A), Ultravist® 300 (Bayer Pharma AG), Visipaque™ 320 (GE Healthcare) and agitated in a controlled manner to get a homogenous suspension. Syringes with loaded beads in contrast media were stored protected from light under refrigeration (2-8℃). Compatibility was determined by measuring epirubicin concentrations in the suspensions in triplicate on day 0, 1, and 7. A reversed phase high-performance liquid chromatography assay with ultraviolet detection was utilized to analyze the concentration and purity of epirubicin. Mixing of epirubicin-loaded beads with different non-ionic contrast media released 0.1-0.5% of epirubicin over a period of 24 h, irrespectively, of the DC bead™ size or type of contrast media. No further elution or degradation was observed after seven days when the admixtures were stored protected from light under refrigeration. Compatibility of epirubicin-loaded DC bead™ with an equal volume of different contrast media in polypropylene syringes is given over a period of seven days. Due to a maximum elution of 0.1-0.5% of epirubicin from loaded DC bead™, admixtures with contrast media can be prepared in advance in centralized cytotoxic preparation units

  8. Fixed drug eruption induced by an iodinated non-ionic X-ray contrast medium: a practical approach to identify the causative agent and to prevent its recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, Ingrid; Block, Wolfgang; Schild, Hans H. [University of Bonn, Department of Radiology, Bonn (Germany); Medina, Jesus; Prieto, Pilar [JUSTESA IMAGEN SA, Biological R and D Department, Madrid (Spain)

    2007-02-15

    We describe the case of a 61-year-old physician who developed a fixed drug eruption (FDE) after i.v. administration of a non-ionic monomeric iodinated X-ray contrast medium (CM) (iopromide). During CM injection, a sensation of heat occurred, which was most intense in the right inguinal region. Four hours later, the FDE arose with a red macule of approximately 2 cm in diameter covering a dermal infiltration in the right inguinal region, and enlarged up to a final size of 15 x 8 cm, accompanied by a burning sensation. The patient's history revealed a similar reaction in the same localization and of the same clinical appearance after CM injection 1 year before. Patch testing 4 months later revealed positive reactions to iomeprol and iohexol. Iopamidol injection for another CT examination 23 months later was well tolerated. Based on these results, we suggest patch testing after CM-induced FDE, which could help to select a CM for future CT examinations. Late onset of adverse CM reactions may manifest as FDE. Patch testing within the previous skin reaction area is the diagnostic tool that should be used to confirm the suspected agent, possible cross-reacting agents and well-tolerated agents. (orig.)

  9. Fixed drug eruption induced by an iodinated non-ionic X-ray contrast medium: a practical approach to identify the causative agent and to prevent its recurrence

    International Nuclear Information System (INIS)

    Boehm, Ingrid; Block, Wolfgang; Schild, Hans H.; Medina, Jesus; Prieto, Pilar

    2007-01-01

    We describe the case of a 61-year-old physician who developed a fixed drug eruption (FDE) after i.v. administration of a non-ionic monomeric iodinated X-ray contrast medium (CM) (iopromide). During CM injection, a sensation of heat occurred, which was most intense in the right inguinal region. Four hours later, the FDE arose with a red macule of approximately 2 cm in diameter covering a dermal infiltration in the right inguinal region, and enlarged up to a final size of 15 x 8 cm, accompanied by a burning sensation. The patient's history revealed a similar reaction in the same localization and of the same clinical appearance after CM injection 1 year before. Patch testing 4 months later revealed positive reactions to iomeprol and iohexol. Iopamidol injection for another CT examination 23 months later was well tolerated. Based on these results, we suggest patch testing after CM-induced FDE, which could help to select a CM for future CT examinations. Late onset of adverse CM reactions may manifest as FDE. Patch testing within the previous skin reaction area is the diagnostic tool that should be used to confirm the suspected agent, possible cross-reacting agents and well-tolerated agents. (orig.)

  10. Variable effects of radiological contrast media on thrombus growth in a rabbit jugular vein thrombosis model

    NARCIS (Netherlands)

    Levi, M. [=Marcel M.; Biemond, B. J.; Sturk, A.; Hoek, J.; ten Cate, J. W.

    1991-01-01

    We studied the effect of an ionic high osmolar contrast medium (Ioxitalamate), an ionic low osmolar contrast medium (Ioxaglate) and various nonionic low osmolar contrast media (Iopamidol, Iopromide and Iohexol) on thrombus growth in a rabbit jugular vein thrombosis model. Thrombus growth was

  11. Contrast venography of the leg: diagnostic efficacy, tolerance, and complication rates with ionic and nonionic contrast media

    International Nuclear Information System (INIS)

    Bettmann, M.A.; Robbins, A.; Braun, S.D.; Wetzner, S.; Dunnick, N.R.; Finkelstein, J.

    1987-01-01

    A prospective, three-center study of two contrast agents for leg venography was performed to evaluate both the relative frequency of adverse effects and whether low-osmolality agents provided significant advantages for this procedure. Fifty-four patients were studied with the standard preparation (iothalamate meglumine) and 57 with a nonionic agent (iopamidol). Both were used at an iodine concentration of 200 mg/mL, and there were no differences in volume of contrast material, duration of infusion, percentage of positive studies, or overall diagnostic adequacy. Patient discomfort was less with iopamidol than with iothalamate (18% vs. 44%), although discomfort was generally mild in both groups. By objective follow-up studies, the frequency of postvenographic thrombosis was not significantly different in the two groups (8% vs. 9%). Contrast venography, then, had a low frequency of complications when either a dilute conventional or a low-osmolality agent was employed. Although the frequency of postvenographic thrombosis was low with both agents, patient discomfort was less with the low-osmolality formulation

  12. The Multi-center Evaluation of the Accuracy of the Contrast MEdium INduced Pd/Pa RaTiO in Predicting FFR (MEMENTO-FFR) Study.

    Science.gov (United States)

    Leone, Antonio Maria; Martin-Reyes, Roberto; Baptista, Sergio B; Amabile, Nicolas; Raposo, Luis; Franco Pelaez, Juan Antonio; Trani, Carlo; Cialdella, Pio; Basile, Eloisa; Zimbardo, Giuseppe; Burzotta, Francesco; Porto, Italo; Aurigemma, Cristina; Rebuzzi, Antonio G; Faustino, Mariana; Niccoli, Giampaolo; Abreu, Pedro F; Slama, Michel S; Spagnoli, Vincent; Telleria Arrieta, Miren; Amat Santos, Ignacio J; de la Torre Hernandez, Jose M; Lopez Palop, Ramon; Crea, Filippo

    2016-08-20

    Adenosine administration is needed for the achievement of maximal hyperaemia fractional flow reserve (FFR) assessment. The objective was to test the accuracy of Pd/Pa ratio registered during submaximal hyperaemia induced by non-ionic contrast medium (contrast FFR [cFFR]) in predicting FFR and comparing it to the performance of resting Pd/Pa in a collaborative registry of 926 patients enrolled in 10 hospitals from four European countries (Italy, Spain, France and Portugal). Resting Pd/Pa, cFFR and FFR were measured in 1,026 coronary stenoses functionally evaluated using commercially available pressure wires. cFFR was obtained after intracoronary injection of contrast medium, while FFR was measured after administration of adenosine. Resting Pd/Pa and cFFR were significantly higher than FFR (0.93±0.05 vs. 0.87±0.08 vs. 0.84±0.08, ptime and costs.

  13. Choice of intravenous contrast material for CT

    International Nuclear Information System (INIS)

    Cohen, M.D.; Herman, E.; Herron, D.; White, S.T.; Smith, J.A.; Cory, D.A.

    1989-01-01

    For CT, minor side effects (e.g., nausea, vomiting, pain) following intravenous administration of contrast medium may degrade image quality by causing patient motion or by delaying scanning. The objective of this study was to see if nonionic contrast agents offer advantages in reducing the incidence of such side effects. One hundred five pediatric patients randomly received iohexol (Omnipaque), Iopamidol (Isovue), or diatrizoate sodium (Hypaque). Contrast medium was given in doses of 2 mL/kg body weight (300 mg of iodine per milliliter). The results are presented in the paper

  14. An evaluation of ultravist - a contrast medium by Schering in angiography

    International Nuclear Information System (INIS)

    Twarkowski, P.; Woynarowski, M.

    1993-01-01

    An angiography with ''uropolina'' (Polfa), ''hexabrix'' (Byk) and ''ultravist'' (Schering) was performed in 30 patients with various vascular disorders. It has appeared, that low-osmolality contrast media (''hexabrix'') and nonionic ones (''ultravist'') less frequently caused the complications than ''uropolina'', widely used by us. (author)

  15. Clinical application of intravascular administration of non-ionic, low osmolar contrast agent, Ioversol (Optiray 320) and its side effects comparison with Meglumine Iothalamate (Conray 60)

    International Nuclear Information System (INIS)

    Hong, Hyun Sook; Kim, Dae Ho; Lee, Hae Kyung; Chung, Moo Chan; Choi, Deuk Lin; Kwon, Kuy Hyang; Kim, Ki Jung

    1990-01-01

    Ioversol, the non-ionic, low osmolar contrast agent has been well characterized chemically and in terms of basic toxicity testing. Ioversol has a fomula similar to that of other nonionic agent. We review the results of intravascular use of this contrast agent, compared ionic contrast media(Meglumine Iothalamate (Conray 60)). Each study was assessed for imaging quality,and patients were monitored vital signs, changes of hematology and blood chemistry and urinalysis before and after contrast administration and were observed for occurrence of side effects. A small number of side effects were reported but no clinically significant sequelae in Ioversol group and much less vital sign changes compared with Conray group. There were no significant changes in vital signs related to the use of Ioversol, and no significant alterations in the renal function parameter or other blood chemistry and hematology measurement were encountered in both contrast media. In most cases, the image qualities were good. In conclusion, Ioversol is safe, well tolerated and efficious for use in intravascular contrast agent, and less vital sign changes and side effect than ionic Meglumine Iothalamte, and Ioversol is likely to provide a useful and acceptable alternative to other low osmolar and nonionic contrast agents

  16. Development of contrast media

    International Nuclear Information System (INIS)

    Krause, W.

    1993-01-01

    Description of all contrast media (ionic and nonionic monomers, ionic and nonionic dimers) was presented. Chemotoxicity, osmolality and viscosity of some contrast agents were analyzed. The main adverse reactions to ionic and nonionic contrast media were described

  17. [Me-too pharmaceuticals -- marketing-strategies of drug producers and drug purchasers. Example: non-ionic contrast media].

    Science.gov (United States)

    Wild, C; Puig, S

    2004-11-01

    In the context of increasing economic pressure upon on hospital budgets, it is inevitable that central and standardized purchasing of pharmaceuticals must be considered. It was the aim of this assessment to analyse the many different non-ionic contrast media/CM products on the actual "clinical relevance of the differences" in order to give advice for a more concerted purchasing of CM. The assessment was commissioned by a large scale Austrian hospital cooperation; it can be regarded as the beginning of a broad strategy against the many new, only rarely innovative, but nevertheless patent-protected pharmaceuticals. Eight different non-ionic contrast media - used in routine care - were compared for their physico-chemical characteristics: osmolality, nephrotoxicity, viscosity, hydrophilicity and electric charge. In a systematic review 193 publications were analysed. The examined CM show similar pharmacokinetic and -dynamic attributes, and no differences of clinical relevance. An optimisation of purchasing pharmaceuticals by standardisation of the range of products takes place in the context of common strategies of producers and buying agents in marketing-economies. The strategies of the pharmaceutical industry (patent protection of me-too drugs, high-price-policy, extensive marketing of up to 40 % of revenue) and the counter-strategies of the central hospital purchasers (market concentration, drug commissions, institutional measures to disentangle interests) are presented - exemplified by contrast media - in this article.

  18. Incompatibility of Contrast Medium and Trisodium Citrate

    International Nuclear Information System (INIS)

    Delcour, Christian; Bruninx, Guy

    2013-01-01

    To test the compatibility of trisodium citrate, a catheter lock solution, with iodinated contrast medium. Iohexol, iobitridol, iodixanol, ioxaglate, ioxithalamate, iomeprol, and iopromide were tested. In all tests, 2 ml of contrast medium were mixed with 2 ml of trisodium citrate solution. Iodixanol and ioxaglate provoked a highly viscous gluelike precipitation when mixed with trisodium citrate. A brief transient precipitate was observed with iohexol, iomeprol, and ioxithalamate. Permanent precipitation occurred with iobitridol and iopromide. One must be aware of the potential for precipitation when contrast medium is mixed with trisodium citrate solution. Before trisodium citrate solution is injected, the catheter should be thoroughly flushed with saline if a contrast medium has previously been injected through it.

  19. Outcomes of premedication for non-ionic radio-contrast media hypersensitivity reactions in Korea

    International Nuclear Information System (INIS)

    Kim, Sae-Hoon; Lee, So-Hee; Lee, Sang-Min; Kang, Hye-Ryun; Park, Heung-Woo; Kim, Sun-Sin; Cho, Sang-Heon

    2011-01-01

    Background: Radio-contrast media (CM)-related adverse reactions are important clinical problems that may cause fatal anaphylaxis. Accordingly, it has been common practice to premedicate patients who have had previous reactions to CM with corticosteroids, antihistamines, and H2 blockers to prevent hypersensitive reactions. However, the effectiveness of premedication has not been properly demonstrated, especially in cases related to non-ionic CM. In this study, we evaluated the effectiveness of premedication at preventing of non-ionic CM immediate-type hypersensitivity reactions. Methods: A total of 30 patients who had been pretreated with corticosteroid and H1 antihistamines and/or H2 blockers in a 3-year period were enrolled. The results of premedication were evaluated in terms of clinical characteristics and the features of breakthrough reactions. Results: Hypersensitivity reactions were not prevented in 5 of the 30 patients who had experienced prior CM reactions (overall recurrence rate after premedication 16.7%; 4/17 patients with mild previous reactions, and 1/13 patients with severe previous reactions). The recurrence rate after premedication was significantly higher in patients with mild previous reactions than in those with severe reactions (23.5% vs. 7.7%; p < 0.001). The breakthrough reactions were similar to the prior reactions in terms of severity and clinical manifestations. Conclusion: Premedication with corticosteroid and H1 antihistamines and/or H2 blockers effectively prevent non-ionic CM-related adverse events in most patients who have had severe previous reactions to CM. However, physicians should be aware of the possibility of premedication failing and of breakthrough reactions, even in cases in which the previous reactions were mild.

  20. Shoulder arthrography: comparison of morbidity after use of various contrast media

    International Nuclear Information System (INIS)

    Hall, F.M.; Goldberg, R.P.; Wyshak, G.; Kilcoyne, R.F.

    1985-01-01

    This prospective study compares immediate and delayed patient discomfort in 177 patients following shoulder arthrography using intraarticular combinations of metrizamide, meglumine/sodium diatrizoate, meglumine diatrizoate, lidocaine, epinephrine, and air. Patients receiving conventional ionic monomeric positive contrast media had a 60% (90/150) incidence of moderate or severe delayed exacerbation of their baseline symptoms; only 14% (3/21) of patients receiving metrizamide, a nonionic contrast medium had similar levels of postprocedural discomfort. Morbidity was somewhat diminished with the use of double-contrast (45%, 34/75) rather than single-contrast (75%, 56/75) examinations, and with avoidance of sodium-containing contrast agents or epinephrine. Nonionic or monovalent polymeric contrast media, despite their present high cost, may be the agents of choice if single-contrast arthrography is performed in joints associated with a high incidence of postprocedural pain

  1. Contrast media in urography, angiography and computerized tomography

    International Nuclear Information System (INIS)

    Taenzer, V.; Zeitler, E.

    1983-01-01

    The fact that new contrast media have been introduced in Germany or are currently undergoing clinical trials prompted the authors to assemble available experiences in a special edition of ''Roentgen-Fortschritte''. Particular prominence is given in the publication to preclinical and clinical experiences with another new non-ionic contrast medium, Iopromide. Experimental and clinical studies both indicate changes in certain clinically pertinent properties of the new contrast media. (orig./MG) [de

  2. The Royal Australian College of Radiologists (RACR) survey of reactions to intravenous ionic and non-ionic contrast media

    International Nuclear Information System (INIS)

    Palmer, J.F.

    1989-01-01

    The Royal Australian College of Radiologists (RACR) expressed concern as to medico-legal implications of the continued use of conventional ionic contrast media in view of the availability of the new low-osmolar media. The new agents had demonstrated significant advantages and it was anticipated that their use would be associated with a lower incidence of undesirable reactions and deaths. However, these new media are significantly more expensive than conventional ionic media and complete changes to these agents has considerable implications for health budgets. Since it was the view of the RACR that there was insufficient information available of the incidence of reactions in clinical use to justify a complete change, a prospective survey of reations to intravenous contrast media injections was initiated. Particpants were issued a simple form, which required for each patient a record of the presence or absence of risk factors, wether ionic or non-ionic contrast media were used, and of the severity of eventual reactions. The results of about 170.000 patients were reported. The survey demonstrated the relative safety of non-ionic media for intravenous use. Despite the relative high cost of these media the continued use of conventional ionic media will become increasingly difficult to justify. (H.W.). 9 refs.; 4 tabs

  3. Investigations of nephrotoxicity caused by ionic and non-ionic contrast media in rats with previously damaged and not previously damaged kidneys and special view to urinary enzyme determinations

    International Nuclear Information System (INIS)

    Hofmeister, R.

    1988-01-01

    In this study ionic (meglumine amidotrizoate) and non-ionic contrast media (SHH 340 AB, Iohexol, Iopromide, Iosimide and Iopamidol) were tested for their nephrotoxicity in rats. During the experiment detections of urea nitrogen, serum creatinine and urinary enzymes as well as histological examinations of the kidneys were carried out for the diagnosis of acute renal damage. The results obtained in this study demonstrate that rats are not very sensitive to non-ionic contrast media with regard to kidney damage and determinations of urinary enzymes are valuable for the diagnosis of contrast media induced acute kidney damage in living animals. (orig./MG) [de

  4. Transient angioedema of small bowel secondary to intravenous iodinated contrast medium

    Directory of Open Access Journals (Sweden)

    Kirankumar N Kulkarni

    2014-01-01

    Full Text Available We report the clinical details and imaging findings of a case of transient angioedema of the small bowel following intravenous administration of non-ionic iodinated contrast material in a 17 year old female with no predisposing risk factors. Findings included long segment, symmetric, circumferential, low-density, bowel wall thickening involving the duodenum, jejunum, and most of the ileum on computed tomography scan obtained at 7 min following intravenous contrast material injection. This entity is self-limiting with a favourable clinical outcome and requires no specific treatment but only aggressive clinical monitoring.

  5. Risk of application of contrast medium in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wende, S.; Speck, U.

    1981-06-01

    The paper deals with the risk associated with the application of contrast medium in CT. The risk is to be seen in intolerance reactions, such as allergic or circulatory reactions and neurotoxic side-effects. In this paper the problems of renal failure caused by the injection of contrast medium are given special attention. Furthermore an iodine-induced hyperthyreosis might result. Especially the possible disturbance of the kidney function means that contrast medium should not be applied arbitrarily and that the examination should be done only by experienced staff. Furthermore the indication for the application of contrast medium in CT should be strictly qualified.

  6. Diffusion of ionic and non-ionic contrast agents in articular cartilage with increased cross-linking--contribution of steric and electrostatic effects.

    Science.gov (United States)

    Kulmala, K A M; Karjalainen, H M; Kokkonen, H T; Tiitu, V; Kovanen, V; Lammi, M J; Jurvelin, J S; Korhonen, R K; Töyräs, J

    2013-10-01

    To investigate the effect of threose-induced collagen cross-linking on diffusion of ionic and non-ionic contrast agents in articular cartilage. Osteochondral plugs (Ø=6mm) were prepared from bovine patellae and divided into two groups according to the contrast agent to be used in contrast enhanced computed tomography (CECT) imaging: (I) anionic ioxaglate and (II) non-ionic iodixanol. The groups I and II contained 7 and 6 sample pairs, respectively. One of the paired samples served as a reference while the other was treated with threose to induce collagen cross-linking. The equilibrium partitioning of the contrast agents was imaged after 24h of immersion. Fixed charge density (FCD), water content, contents of proteoglycans, total collagen, hydroxylysyl pyridinoline (HP), lysyl pyridinoline (LP) and pentosidine (Pent) cross-links were determined as a reference. The equilibrium partitioning of ioxaglate (group I) was significantly (p=0.018) lower (-23.4%) in threose-treated than control samples while the equilibrium partitioning of iodixanol (group II) was unaffected by the threose-treatment. FCD in the middle and deep zones of the cartilage (pionic iodixanol showed no changes in partition after cross-linking, in contrast to anionic ioxaglate, we conclude that the cross-linking induced changes in charge distribution have greater effect on diffusion compared to the cross-linking induced changes in steric hindrance. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. Experimental investigations on the influence of the contrast medium Iopamiro 300 mixed with vegetal mucus on the nasolacrimal system and external eye tissues; Badania doswiadczalne nad wplywem srodka cieniujacego Iopamiro 300 ze sluzem roslinnym na drogi lzowe i przedni odcinek oka

    Energy Technology Data Exchange (ETDEWEB)

    Rubaj, B.; Koper, S. [Akademia Rolnicza, Lublin (Poland); Wolski, T.; Toczowski, J.; Wolski, J.; Langwinska-Wosko, E. [Akademia Medyczna, Lublin (Poland)

    1994-12-31

    Using low osmolality, nonionized contrast medium Iopamiro-300, Bracco mixed with the mucus prepared from the seed flax (``Linum usitatissimum, L.``), a dacryocistorhinography was performed experimentally on 8 healthy mongrel dogs. Assessing the occurrence of local and general complications was the aim of the investigation. On the basis of a radiographic examination it has been shown that the mixture of the contrast medium and seed flax mucus appeared to be a very useful compound for dacryocistorhinography, especially for the evaluation of nasolacrimal duct system course and its patency. Clinical observations and a histological examination proved that this compound of the contrast medium was well tolerated by the mucous membrane of the nasolacrimal system and the external eye tissues. (author). 21 refs, 4 figs.

  8. Risk of application of contrast medium in computed tomography

    International Nuclear Information System (INIS)

    Wende, S.; Speck, U.; Schering A.G., Berlin

    1981-01-01

    The paper deals with the risk associated with the application of contrast medium in CT. The risk is to be seen in intolerance reactions, such as allergic or circulatory reactions and neurotoxic side-effects. In this paper the problems of renal failure caused by the injection of contrast medium are given special attention. Furthermore an iodine-induced hyperthyreosis might result. Especially the possible disturbance of the kidney function means that contrast medium should not be applied arbitrarily and that the examination should be done only by experienced staff. Furthermore the indication for the application of contrast medium in CT should be strictly qualified. (orig.) [de

  9. Current iodinated contrast media

    International Nuclear Information System (INIS)

    Stacul, F.

    2001-01-01

    The number of scientific papers on iodinated contrast media is declining. Indeed, comparative trials between high-osmolality and low-osmolality agents largely showed the higher safety and tolerability of the latter, and this is no longer a matter of discussion. Only financial constraints could prevent a total conversion to low-osmolality agents. Research comparing low-osmolality (nonionic monomers, ionic dimer) and iso-osmolality contrast media (nonionic dimers) are still ongoing. Both classes of nonionic compounds proved safer than the ionic dimer. The relative merits of nonionic monomers and nonionic dimers are a matter for debate, and criteria for a selective use of different agents for different procedures could be discussed. (orig.)

  10. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT - A pooled analysis of two randomized trials

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.; Morcos, Sameh K.

    2009-01-01

    The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients with glomerular filtration rate (GFR) 40 ml/min, 4.6% when GFR <40 ml/min and 7.8% in patients with GFR <30 ml/min. The incidence of CIN was significantly higher after iodixanol than after LOCM (seven patients, 4.7% following IOCM, no CIN cases following the LOCM; p = 0.007). Significant differences in favor of the LOCM were also observed in patients with GFR <40 ml/min and GFR <30 ml/min. Following the IV administration of nonionic contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM iopamidol and iomeprol, especially in high-risk patients. Differences in osmolality between these LOCM and iodixanol do not play a role in the genesis of CIN. (orig.)

  11. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT - A pooled analysis of two randomized trials

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [University of Copenhagen, Department of Diagnostic Radiology, Copenhagen University Hospital Herlev, and Department of Diagnostic Sciences, Faculty of Health Sciences, Herlev (Denmark); Morcos, Sameh K. [University of Sheffield, Department of Diagnostic Imaging, Northern General Hospital, Sheffield (United Kingdom)

    2009-04-15

    The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients with glomerular filtration rate (GFR) <60 ml/min undergoing contrast-enhanced MDCT examinations and to compare the rates of CIN following the IV administration of low-osmolar contrast media (LOCM, iopamidol and iomeprol) and an iso-osmolar contrast medium (IOCM, iodixanol). A total of 301 adult patients with moderate-to-severe renal failure received a similar IV contrast dose (40 gI). Serum creatinine (SCr) was measured at screening, baseline and 48-72 {+-} 6 h after the MDCT examination. Primary CIN outcome was an increase in SCr {>=}0.5 mg/dl ({>=}44.2 {mu}mol/l) from baseline. The CIN rates were 2.3% in the total population, 0.6% when GFR >40 ml/min, 4.6% when GFR <40 ml/min and 7.8% in patients with GFR <30 ml/min. The incidence of CIN was significantly higher after iodixanol than after LOCM (seven patients, 4.7% following IOCM, no CIN cases following the LOCM; p = 0.007). Significant differences in favor of the LOCM were also observed in patients with GFR <40 ml/min and GFR <30 ml/min. Following the IV administration of nonionic contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM iopamidol and iomeprol, especially in high-risk patients. Differences in osmolality between these LOCM and iodixanol do not play a role in the genesis of CIN. (orig.)

  12. Iodinated contrast media and contrast-induced nephropathy: is there a preferred cost-effective agent?

    Science.gov (United States)

    Sharma, Samin K

    2008-05-01

    Over 20 years have passed since the introduction of the tri-iodinated low-osmolar nonionic contrast agents such as iopamidol, iohexol, ioversol and iopromide. During this time, most cardiology practices have switched to these nonionic agents to avoid the nuisance side effects and cardiac adverse events associated with the older ionic contrast agents. Although the improved tolerability of the nonionic agents is generally attributed to their decreased osmolality (approximately half that of the older ionic contrast agents), in fact, these contrast agents also differ from the older agents in their ionicity, viscosity and direct chemotoxicity. The impact of these properties on safety, together with cost differences, should be considered when selecting a contrast agent.

  13. Prevention of adverse reactions to intravascular contrast media

    International Nuclear Information System (INIS)

    Soyer, P.; Levesque, M.

    1990-01-01

    The exact mechanisms of adverse reactions to contrast media are still imperfectly known. However, these reactions may be classified as idiosyncratic. Non-idiosyncratic reactions can be prevented by using new, non-ionic contrast agents. Idiosyncratic reactions can be prevented by specific premedication. Patients with a history of idiosyncratic reaction may benefit from corticosteroids and antihistamines administered prophylactically. Patients who seem to be more likely than others to react to contrast media must be premedicated, the risk of reaction being identified and evaluated by questioning. It has recently been suggested that all patients about to receive an intravascular injection of contrast medium should also be premedicated [fr

  14. Paediatric cardiac catheterization. Controlled, randomized study of two iodinated contrast media: iopromide 300 and ioxaglate 320 mgI/ml

    International Nuclear Information System (INIS)

    Amiel, M.; Revel, D.

    1989-01-01

    Thirty-one children were included in a prospective randomized trial comparing a new non-ionic contrast medium, iopromide 300 and the ionic low osmolar contrast medium, ioxaglate 320 mgI/ml in pediatric cardiac catheterization. There were fewer adverse effects with iopromide but no statistically significant difference was demonstrated in this small population, with a very low incidence of allergoid reactions; this tendency was confirmed by meta-analysis of the multicentre study [fr

  15. Comparison of neutral oral contrast versus positive oral contrast medium in abdominal multidetector CT

    International Nuclear Information System (INIS)

    Berther, Ralph; Eckhardt, Boris; Zollikofer, Christoph L.; Patak, Michael A.; Erturk, Sukru M.

    2008-01-01

    To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetector row computed tomography (MDCT). Their results were compared with those of 100 patients given a positive oral contrast agent. Qualitative and quantitative measurements were done on different levels of the gastrointestinal tract by three experienced readers. Patients given the neutral oral contrast agent showed significant better qualitative results for bowel distension (P<0.001), homogeneity of the luminal content (P<0.001), delineation of the bowel-wall to the lumen (P<0.001) and to the mesentery (P<0.001) and artifacts (P<0.001), leading to a significant better overall image quality (P<0.001) than patients receiving positive oral contrast medium. The quantitative measurements revealed significant better distension (P<0.001) and wall to lumen delineation (P<0.001) for the patients receiving neutral oral contrast medium. The present results show that the neutral oral contrast agent (mannitol) produced better distension, better homogeneity and better delineation of the bowel wall leading to a higher overall image quality than the positive oral contrast medium in a non-selected patient population. (orig.)

  16. Late adverse reactions to intravascular iodinated contrast media

    International Nuclear Information System (INIS)

    Webb, Judith A.W.; Stacul, Fulvio; Thomsen, Henrik S.; Morcos, Sameh K.

    2003-01-01

    Late adverse reactions to intravascular iodinated contrast media are defined as reactions occurring 1 h to 1 week after contrast medium injection. They have received increasing interest over the past decade, but their prevalence remains uncertain and their pathophysiology is not fully understood. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and to issue guidelines. An extensive literature search was carried out and summarized in a report. Based on the available information, simple guidelines have been drawn up. The report and guidelines were discussed at the 8th European Symposium on Urogenital Radiology in Genoa. Late adverse reactions after intravascular iodinated contrast medium include symptoms such as nausea, vomiting, headache, itching, skin rash, musculoskeletal pain, and fever. A significant proportion of these reactions is unrelated to the contrast medium; however, allergy-like skin reactions are well-documented side effects of contrast media with an incidence of approximately 2%. Late reactions appear to be commoner after non-ionic dimers. The majority of late skin reactions after contrast medium exposure are probably T-cell-mediated allergic reactions. Patients at increased risk of late skin reactions are those with a history of previous contrast medium reaction and those on interleukin-2 treatment. Most skin reactions are self-limiting and resolve within a week. Management is symptomatic and similar to the management of other drug-induced skin reactions. (orig.)

  17. Radiculography with water-soluble contraste medium

    International Nuclear Information System (INIS)

    Araujo Pinheiro, R.S. de

    1987-01-01

    The etiologic diagnosis of the lumbar pain is discussed. The radiculography with water-soluble contrast medium is used and 250 cases are studied. Some practical criteria of indication executation and interpretation of the examination are reported. (M.A.C.) [pt

  18. Comparison of renal toxicity after injection of CT contrast medium and MR contrast medium: change of renal function in acute renal failure rat models

    International Nuclear Information System (INIS)

    Han, Young min; Lee, Young Hwan; Kim, Sang Won; Jin, Kong Young; Kim, Won; Chung, Gyung Ho

    2002-01-01

    To determine renal toxicity through changes in renal function after the injection of CT and MRI contrast media into rats in which acute renal failure (ARF) was induced. To cause acute renal failure, the abdominal cavity of 110 male rats each weighing 250-300 gm was opened via a midline incision under anesthesia. Microvascular clamps were placed on both renal arteries and veins to completely block renal blood flow for 45 minutes, and were then removed, allowing blood flow to return to the kidneys. ARF, defined as a two-fold difference in the creatinine level before ARF and 48 hours after, was successfully induced in 60 of the rats. These were divided into two groups: one was injected with CT contrast medium and the other with MRI contrast medium. Each CT and MRI group was divided into a low dose (0.5 cc/kg, 0.2 ml/kg), standard dose (2 cc/kg, 0.8 ml/kg), and high dose (8 cc/kg, 3.2 ml/kg) sub-group; thus, there was a total of six groups with ten rats in each. Blood samples were obtained before ARF, 48 hours after, and 48 hours after contrast injection, and CT scanning and MRI were performed after blood sampling at 48 hours. In each group, creatinine levels 48 hours after contrast injection were compared by means of the ANOVA test. There were no significant differences in creatinine levels between the CT and MRI contrast medium groups (p=0.116), nor between the animals to which different doses of CT and MRI contrast medium, were administered. After both standard and high doses, CT and MRI provided good images. In rats in which acute renal failure was induced, renal function did not change according to whether CT or MRI contrast medium was injected. Thus, the two media induce similar levels of toxicity

  19. Efficacy of high iodine concentration contrast medium with saline pushing in hepatic CT in patients with chronic liver disease. Comparison of high doses-standard contrast medium concentration

    International Nuclear Information System (INIS)

    Matoba, Munetaka; Kondo, Tamaki; Nishikawa, Takahiro; Kuginuki, Yasuaki; Yokota, Hajime; Higashi, Kotaro; Tonami, Hisao

    2006-01-01

    The aim of this study was to compare the enhancement of liver parenchyama with high iodine concentration contrast medium with saline pushing to that with high doses standard iodine concentration in hepatic CT in patients with chronic liver disease. There was no statistically significant difference regarding to the enhancement of liver parenchyama between the 370 mgI/ml of contrast medium with saline pushing and high doses standard iodine concentration contrast medium. (author)

  20. Local blood-brain barrier penetration following systemic contrast medium administration

    International Nuclear Information System (INIS)

    Utz, R.; Ekholm, S.E.; Isaac, L.; Sands, M.; Fonte, D.

    1988-01-01

    The present study was initiated by a severe complication in a patient with renal dysfunction who developed cortical blindness and weakness of her left extremities 30 hours following renal and abdominal angiography. To evaluate the impact of prolonged high serum concentrations of contrast medium (CM) this clinical situation was simulated in a laboratory model using sheep with elevated serum levels of contrast medium maintained for 48 hours. The experimental data did not support the theory that the prolonged exposure to high circulating levels of contrast medium (4 ml/kg body weight of meglumine diatrizoate 60%) is sufficient alone to cause penetration of the blood-brain barrier. (orig.)

  1. Recommendation to use iso-osmotic contrast medium in interventional treatment

    International Nuclear Information System (INIS)

    Zhou Bing; Cheng Yongde

    2012-01-01

    With the rapid development of imaging diagnostic and interventional therapeutic techniques, the contrast medium (CM) has been used more and more common in clinical practice, and meanwhile more and more attention has been paid to the CM-related adverse events. Contrast induced nephropathy (CN) is the most common CM-related adverse event, and CM-related neurotoxicity has already attracted the physicians' attention. The osmotic pressure of the iso-osmotic contrast medium (IOCM) is quite the same as that of the plasma, and therefore its safety is higher than that of low-osmotic contrast medium (LOCM), the patient's tolerance to IOCM is better than that to LOCM. For this reason, the use of IOCM should be strongly recommended in interventional procedures, which is of great significance to the reduction of the occurrence of CM-related adverse events. (authors)

  2. Contrast material-enhanced CT of the abdomen

    International Nuclear Information System (INIS)

    Fishman, E.K.; Kuhlman, J.E.; Garrity, M.; Paris, D.A.

    1988-01-01

    A randomized double-blind comparison of a nonionic contrast agent (Omnipaque) and an ionic contrast agent (Hypaque) was performed to determine any difference between the two agents in the quality and performance of computed body tomography (CT). A total of 40 patient studies were performed on a state-of-the-art CT scanner with similar scanning techniques. The contrast agent was administered intravenously as a rapid infusion in all cases. The image quality of the abdominal CT scans was good to excellent in all cases. There was no difference between the ionic and nonionic agents in terms of study quality. The 20 patients who received nonionic contrast agents had no major or minor reactions. Five of the 20 patients receiving the ionic contrast agent had a total of ten adverse reactions, including nausea and vomiting, nasal congestion, sneezing, and urticaria. The authors conclude that nonionic contrast agents provide high-quality CT scans equal to those provided by ionic agents and also result in fewer reactions and less discomfort

  3. Controlled synthesis of La1−xSrxCrO3 nanoparticles by hydrothermal method with nonionic surfactant and their ORR activity in alkaline medium

    International Nuclear Information System (INIS)

    Choi, Bo Hyun; Park, Shin-Ae; Park, Bong Kyu; Chun, Ho Hwan; Kim, Yong-Tae

    2013-01-01

    Graphical abstract: We demonstrate that Sr-doped LaCrO 3 nanoparticles were successfully prepared by the hydrothermal synthesis method using the nonionic surfactant Triton X-100 and the applicability of La 1−x Sr x CrO 3 to oxygen reduction reaction (ORR) electrocatalysis in an alkaline medium. Compared with the nanoparticles synthesized by the coprecipitation method, they showed enhanced ORR activity. - Highlights: • Sr-doped LaCrO 3 nanoparticles were successfully prepared by the hydrothermal method using the nonionic surfactant. • Homogeneously shaped and sized Sr-doped LaCrO 3 nanoparticles were readily obtained. • Compared with the nanoparticles synthesized by the coprecipitation method, they showed an enhanced ORR activity. • The main origin was revealed to be the decreased particle size due to the nonionic surfactant. - Abstract: Sr-doped LaCrO 3 nanoparticles were prepared by the hydrothermal method with the nonionic surfactant Triton X-100 followed by heat treatment at 1000 °C for 10 h. The obtained perovskite nanoparticles had smaller particle size (about 100 nm) and more uniform size distribution than those synthesized by the conventional coprecipitation method. On the other hand, it was identified with the material simulation that the electronic structure change by Sr doping was negligible, because the initially unfilled e g -band was not affected by the p-type doping. Finally, the perovskite nanoparticles synthesized by hydrothermal method showed much higher ORR activity by over 200% at 0.8 V vs. RHE than those by coprecipitation method

  4. Radiculography with reduced amounts of contrast medium

    International Nuclear Information System (INIS)

    Signorini, E.; Caputo, N.; Chiurulla, C.; Ciorba, E.; Pelliccioli, G.P.; Cianciulli, E.

    1984-01-01

    Because of the frequency and seriousness of side effects observed after radiculography, due to, among the other things, the amount of contrast medium, the authors describe a method that gives diagnostically satisfactory results using a low dose of contrast and a tangent-beam technique. Among 106 patients undergoing radiculography with a tangent-beam technique and Iopamidol, only 4 developed mild side effects, namely headache in three cases and headache with nausea in one. (Author)

  5. Targeting cancer chemotherapeutic agents by use of lipiodol contrast medium

    International Nuclear Information System (INIS)

    Konno, T.

    1990-01-01

    Arterially administered Lipiodol Ultrafluid contrast medium selectively remained in various malignant solid tumors because of the difference in time required for the removal of Lipiodol contrast medium from normal capillaries and tumor neovasculature. Although blood flow was maintained in the tumor, even immediately after injection Lipiodol contrast medium remained in the neovasculature of the tumor. To target anti-cancer agents to tumors by using Lipiodol contrast medium as a carrier, the characteristics of the agents were examined. Anti-cancer agents had to be soluble in Lipiodol, be stable in it, and separate gradually from it so that the anti-cancer agents would selectively remain in the tumor. These conditions were found to be necessary on the basis of the measurement of radioactivity in VX2 tumors implanted in the liver of 16 rabbits that received arterial injections of 14C-labeled doxorubicin. Antitumor activities and side effects of arterial injections of two types of anti-cancer agents were compared in 76 rabbits with VX2 tumors. Oily anti-cancer agents that had characteristics essential for targeting were compared with simple mixtures of anti-cancer agents with Lipiodol contrast medium that did not have these essential characteristics. Groups of rabbits that received oily anti-cancer agents responded significantly better than groups that received simple mixtures, and side effects were observed more frequently in the groups that received the simple mixtures. These results suggest that targeting of the anti-cancer agent to the tumor is important for treatment of solid malignant tumors

  6. Clinical observation of the adverse drug reactions caused by non-ionic iodinated contrast media: results from 109,255 cases who underwent enhanced CT examination in Chongqing, China.

    Science.gov (United States)

    Li, X; Chen, J; Zhang, L; Liu, H; Wang, S; Chen, X; Fang, J; Wang, S; Zhang, W

    2015-03-01

    To analyse the pattern and factors that influence the incidence of adverse drug reactions (ADRs) induced by non-ionic iodinated contrast media and to evaluate their safety profiles. Data from 109,255 cases who underwent enhanced CT examination from 1 January 2008 to 31 August 2013 were analysed. ADRs were classified according to the criteria issued by the American College of Radiology and the Chinese Society of Radiology. A total of 375 (0.34%) patients had ADRs, including 281 mild (0.26%); 80 moderate (0.07%); and 14 severe (0.01%) ADRs; no death was found. 302 (80.53%) of the ADRs occurred within 15 min after examination. Patients aged 40-49 years (204 cases, 0.43%; p contrast media are mainly mild ones, while moderate or severe ADRs are relatively rare, suggesting that enhanced CT examination with non-ionic iodinated contrast media is highly safe, and severe adverse events will seldom occur under appropriate care. The study included 109,255 patients enrolled in various types of enhanced CT examinations, which could reflect ADR conditions and regulations in Chinese population accurately and reliably.

  7. Contrast enhancement technique in brain 3D-CTA studies. Optimizing the amount of contrast medium according to scan time based on TDC

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi

    2008-01-01

    In three-dimensional CT angiography (3D-CTA), good reproducibility can be obtained by maintaining the maximum CT numbers (HU) at a specified level. However, the correlation between the scan time and the injection time showed that the maximum CT numbers increased and varied due to the additional contrast enhancement effect from recirculation of the injected contrast medium for longer injection times when the dose of iodinated contrast medium per unit time (mgI/s) was maintained at a specified level based on the time-density curve (TDC) of the phantom. The amount of contrast medium employed at our hospital has been optimized based on an iodinated contrast medium dose per unit time providing a contrast enhancement effect of 300 HU in the middle cerebral artery. Using this standard, a TDC phantom was employed to obtain an iodinated contrast medium dose per unit time, permitting equivalent maximum CT values (used as standard values) to be obtained by changing the injection time. A contrast-enhancement technique that accounts for the variation in the scan time was evaluated. Strong correlations were observed between the scan time and the injection time (R 2 =0.969) and between the injection time and the dose of iodinated contrast medium per unit body weight (R 2 =0.994). We conclude that adjusting the dose of iodinated contrast medium per unit body weight per unit time according to the scan time permits optimization of the contrast-enhancement technique. (author)

  8. MRI of the liver with the new contrast medium Gd-BOPTA

    International Nuclear Information System (INIS)

    Vogl, T.J.; Pegios, W.; Balzer, J.; Lissner, J.; Pirovano, G.

    1992-01-01

    A phase 1 study on 8 normals has been carried out to determine the effectiveness and safety during MRI of a new hepatobiliary contrast medium Gd-BOPTA for causing enhancement of the upper abdominal organs. Gradient echo sequences (flash), T 1 and T 2 -weighted spin echo sequences and turbo-flash sequences were used. The contrast medium was given as a single infusion in various concentrations (0.005, 0.05, 0.1 and 0.2 mmol/kg body weight). Optimal contrast of liver parenchyma was obtained with a dose of 0.05-0.1 mmol/kg body weight, resulting in contrast increase of 149.1% during gradient echo sequences and 107.8% during T 1 spin echo sequences. In general, the increased contrast lasted for about two hours. Because of the biliary and renal excretion there was an enormous increase in signal intensity of the bile ducts and a significant increase in the kidneys and ureters. The results of the first in-vivo-trial of Gd-BOPTA encourages the performance of further clinical studies of this new hepatobiliary contrast medium. (orig.) [de

  9. Computed tomography using contrast medium in disorders of the patello-femoral joint

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kenji; Chiba, Mitsuho; Morita, Hiromi; Kikuchi, Toshihiko; Shimada, Yoichi; Yamamoto, Masahiro; Tozawa, Kazuma

    1985-01-01

    The morphology and alignment of the articular cartilage of the patello-femoral joint were examined by computed tomography (CT) using a contrast medium in 15 patients with a chief complaint of patellar pain. CT was undertaken immediately after injecting a contrast medium and air into the knee joint. Retention and irregularity of the contrast medium in the joint estimated the expansion and depth of lesions in patients with osteomalacia of the auricular joint or osteoarthritis of the knee, and the thickness of the auricular cartilage. Considering the individual differences of the patella itself and specificity of the form of the auricular cartilage, the auricular joint should also be examined in terms of alignment of the cartilage surface. CT using a contrast medium is a simple, less invasive method for evaluating disorders of the patello-femoral joint.

  10. [Comparison of diagnostic quality in hysterosalpingography between iodinated non-ionic contrast media with low and high osmolarity].

    Science.gov (United States)

    Piccotti, K; Guida, D; Carbonetti, F; Stefanetti, L; Macioce, A; Cremona, A; David, V

    Comparison of diagnostic quality in hysterosalpingography between low and high-osmolality contrast media. We performed a retrospective evaluation of two cohorts of patients who underwent HSG using contrast media with different osmolarity: the first group ,47 patients, underwent hysterosalpingography in the period September 2011-December 2012 using Iopromide 370 mg/ml; the second group, 50 patients, underwent HSG from January 2013 to October 2013 using Iomeprol 400 mg/ml. Three radiologists, in consensus reading,, reviewed the radiographs by assessing the following four parameters: opacification of the uterine cavity, uterine profiles definition, Fallopian tubes visualization, contrast media spillage into peritoneum. A score-scale from 0 to 3 was assigned for each of the mentioned parameter (0 = minimum non-diagnostic exam, 1 = sufficient examination; 2 = good quality examination; maximum 3 = high quality images). We documented a statistically significant higher quality in displaying Fallopian tubes among patients studied through high osmolarity contrast medium (Iopromide 370 mg/ml) than what obtained through lower osmolarity contrast medium (Iomeprol 400 mg/ml). The use of high osmolarity contrast medium enabled better visualization of the tubes and a greater number of diagnoses of chronic aspecific salpigintis due to the increased osmolality and viscosity of Iomeprol 400 mg/ml. There were no significant differences between the two contrast agents in the evaluation of intra-uterine pathology and in the evaluation of the tubal patency.

  11. Potential mechanisms behind contrast medium-induced nephropathy

    African Journals Online (AJOL)

    How contrast medium-induced nephropathy (CIN) comes about is poorly understood, although CIN is a common cause of acute renal failure. Hitherto, the various studies performed have led to different interpretations and partially contradictory conclusions. This article aimed to review the mechanisms underlying CIN and to ...

  12. Effects of use of the lodine contrast medium on gamma camera imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pyo, Sung Jae; Cho, Yun Ho [Dept. of Nuclear Medicine, Inha University hospital, Incheon (Korea, Republic of); Choi, Jae Ho [Dept. of Radiological Technology, Ansan College, Ansan (Korea, Republic of)

    2016-12-15

    Effects of Gamma camera imaging on gamma ray counting rates as a function of use and density of the iodine contrast medium currently in primary use for clinics, and changes in gamma ray counting rates as a function of the contrast medium status upon attenuation correction using a CT absorption coefficientin an SPECT/CT attenuation correction will be considered herein. For experimental materials used 99mTcO4 370 MBq and Pamiray 370 mg, Iomeron 350 mg, Visipaque 320 mg, Bonorex 300 mg of iodine contrast medium. For image acquisition, planar imaging was consecutively filmed for 1, 2, 3, 4, 5 min, respectively, 30 min after administration of 99mTcO4. while 60 views were filmed per frame for 20 min at 55 min for the SPECT/CT imaging. In planar imaging, the gamma ray counting rates as a function of filming time were reduced showing a statistically significant difference when mixed according to the type of contrast medium density rather than when the radioactive isotope 99mTcO4 and the saline solution were mixed. In the tomography for mixing of the radioactive isotope 99mTcO4 and saline solution, the mean counting rate without correction by the CT absorption coefficient is 182±26 counts, while the counting rate with correction by the CT absorption coefficient is 531.3±34 counts. In the tomography for mixing of the radioactive isotope 99mTcO4 and the saline solution with the contrast medium, the mean values before attenuation correction by CT absorption coefficient were 166±29, 158.3±17, 154±36, and 150±33 counts depending on the densities of the contrast medium, while the mean values after attenuation correction were 515±03, 503±10, 496±31, and 488.7±33 counts, showing significant differences in both cases when comparatively evaluated with the imaging for no mixing of the contrast medium. Iodine contrast medium affects the rate of gamma ray. Therefore, You should always be preceded before another test on the day of diagnosis.

  13. Application of iodic contrast media in roentgen examinations

    International Nuclear Information System (INIS)

    Mielecki, T.; Januszkiewicz-Mielecka, K.; Kukula, A.; Szechinski, J.

    1993-01-01

    An analysis of adverse reactions after administration of iodic contrast media in 1780 patients in 1952 various X-ray examinations is presented. Various preparations by different producers were used. As a rule, domestic contrast media were administered in non high-risk patients, whereas imported contrast media were applied in patients with documented high-risk factors (20%) and nonionic compounds were intended for patients of severe clinical condition (10%). Adverse reactions occurred in 6.9% of non high-risk patients and in 10.9% of high-risk patients. Nonionic preparations caused adverse reactions in 5.6%. Considering the significant differences in prices of domestic, imported and nonionic contrast media, authors advice to use safer but clearly more expensive preparations in patients with documented factors of increased risk. (author)

  14. Adsorption of non-ionic ABC triblock copolymers: Surface modification of TiO2 suspensions in aqueous and non-aqueous medium

    Science.gov (United States)

    Lerch, Jean-Philippe; Atanase, Leonard Ionut; Riess, Gérard

    2017-10-01

    A series of non-ionic ABC triblock copolymers, such as poly(butadiene)-b-poly(2-vinylpyrridine)-b-poly(ethylene oxide) (PB-P2VP-PEO) were synthesized by sequential anionic polymerizations. For these copolymers comprising an organo-soluble PB and a water-soluble PEO block, their P2VP middle block has been selected for its anchoring capacity on solid surfaces. The adsorption isotherms on TiO2 were obtained in heptane and in aqueous medium, as selective solvents. In both of these cases, the P2VP middle block provides the surface anchoring, whereas PB and PEO sequences are acting as stabilizing moieties in heptane and water respectively. By extension to ABC triblock copolymers of the scaling theory developed for diblock copolymers, the density of adsorbed chains could be correlated with the molecular characteristics of the PB-P2VP-PEO triblock copolymers. From a practical point a view, it could be demonstrated that these copolymers are efficient dispersing agents for the TiO2 pigments in both aqueous and non-aqueous medium.

  15. Improve identification of details in double-contrast examination of the stomach by means of a new contrast medium mixture

    International Nuclear Information System (INIS)

    Tenner, R.

    1984-01-01

    In a contrast medium study, 100 patients were employed for a comparison between the contrast medium Mikropaque liquid and a mixture of Mikropaque HD and Mikropaque liquid in double-contrast examination of the stomach. The special feature of this method was that one and the same stomach was examined in each case with both contrast media. The new contrast media mixture with Mikropaque HD represents a step forward; the contrast could be enhanced in 80% of the cases, and the finely contoured relief became visible in two-thirds of the cases, compared with one-third of the examined patients before this method was introduced. (orig.) [de

  16. Ionizing and non-ionizing radiations

    International Nuclear Information System (INIS)

    1994-01-01

    The monograph is a small manual to get a knowledge of ionizing and non-ionizing radiations. The main chapters are: - Electromagnetic radiations - Ionizing and non-ionizing radiations - Non-ionizing electromagnetic radiations - Ionizing electromagnetic radiation - Other ionizing radiations - Ionizing radiation effects - The Nuclear Safety Conseil

  17. Adverse effects in coronary angiography: a comparative study of different temperature contrast medium

    International Nuclear Information System (INIS)

    Zhou Peng; Wang Qiulin; Cai Guocai; Li Lu; Jiang Licheng; Yang Zhen; Huang Xiuping

    2011-01-01

    Objective: To investigate the correlation between different temperature contrast medium and the occurrence of adverse effects, including the chest discomfort, the changes of heart rate, ST segment and T wave, the operating time and the used dosage of contrast medium, in performing coronary angiography. Methods: According to the contrast medium temperature used in coronary angiography, the patients were randomly divided into two groups: room temperature group (n=521) and warm temperature group (n=522). The contrast medium used in warm temperature group was bathed in 37 ℃ water for 60 minutes when the coronary angiography was carried out. The T Wave amplitude changes ≥ 0.01 mv, ST segment depression ≥ 0.05 mv, changes in heart rate ≥ 10 times/min were brought into the positive accounting. The occurrence of adverse effects, such as palpitation, chest distress and pectoralgia, the operative time and the used dosage of contrast medium were recorded. The results were analyzed and compared between the two groups. Results: Statistically significant differences in the changes of heart rate, ST segment deviation, T wave change and operating time existed between the two groups (P<0.05). And the difference in the occurrence of adverse effects between the two groups was also statistically significant (P<0.05). Conclusion: When performing coronary angiography, warming of the contrast medium with water bath is greatly conducive to the prevention of cardiac adverse effects. (authors)

  18. The affects of contrast medium on renal function in selective coronary angiography and intervention

    International Nuclear Information System (INIS)

    Chen Yueguang; Lv Baojing

    2006-01-01

    Selective coronary angiography and intervention with injection of contrast medium into the coronary arteries has become very common in dealing with coronary cardiac diseases. The excretion of contrast medium through kidneys may lead to acute renal functional insufficiency, especially for those suffering from chronic nephropathy, diabetes and cardiac functional disorder to form the so called 'contrast medium nephropathy' which is considered as the number second drug induced acute renal functional failure. Although routine preventive measure including low osmotic contrast medium and fine hydrotherapy have been taken, 14% incidences still occur with renal functional damage. The majority could be reversible but the minority needs emergent hemodialysis or even with persistent renal functional damage in a few ones. (authors)

  19. Valuation of using saline flush technique of contrast medium on abdominal multidetector row CT scanning

    International Nuclear Information System (INIS)

    Zhao Hong; Wang Ying; He Yanli; Liu Xiaobing; Bao Shiliang; Han Mingjun

    2006-01-01

    Objective: The purpose of this study was to compare the enhancement degree of abdomen organs and vessels after different amount of contrast medium using saline flush in abdomen MDCT scanning, which aimed to not affect contrast enhancement, decreased the amount of contrast medium, and reduced the side-effect. Methods: This study group consisted of 75 patients who were referred for contrast enhanced abdominal MDCT for various reasons. Patients were allocated into three groups: injection of 100ml of contrast medium only (A group), injection of 80ml pushed with 20ml of saline solution (B group), and injection of 70ml pushed with 30ml of saline solution (C group). Attenuation values were measured from the liver, spleen, pancreas, kidney, aorta, portal vein, and inferior vena cava in 33 second and 80 second of imaging after injection contrast medium. Results: The portal venous phases of the spleen, pancreas, kidney, aorta, portal vein had statistically significant difference among groups A, B and C. Post hoc test showed statistically significant difference between A group and C group, But no statistically significant difference during the portal venous phases of the pancreas and the kidney between A group and B group. Conclusion: Using a saline flush technique after the injection contrast medium in abdominal MDCT reduced waste of contrast medium and decrease in nephrotoxicity, at the same time, it would not lose important diagnostic information and saved patients cost for the contrast medium. (authors)

  20. Advice on the management of reactions to intravenous contrast media

    International Nuclear Information System (INIS)

    1996-01-01

    The College has previously issued guidelines for the management of adverse reactions to intravenous ionic and non-ionic contrast media. The following updated guidelines are applicable to both children and adults. The reported adverse reaction rate to conventional ionic contrast media is about 5%, the vast majority of reactions being of a minor nature, and to the newer non-ionic contrast media, approximately 1%. The rare serious reaction, with an estimated incidence of 0.05% with ionic contrast media and substantially less with non-ionic media, must be treated quickly and appropriately. Identification and symptomatic characterisation of the reaction are the key first steps and should be followed by ad hoc management based on general principles. (author)

  1. Extravasation of contrast medium during CT examination: An ...

    African Journals Online (AJOL)

    2013-03-31

    Extravasation of contrast medium during CT examination: An observational casecontrol study. ... Methods: every incident of extravasation which occurred between March 2012 and March 31, 2013 was recorded in an extravasation form. Ethics Committee approval was obtained and the patients gave their consent to ...

  2. Quantitative contrast-enhanced mammography for contrast medium kinetics studies

    Science.gov (United States)

    Arvanitis, C. D.; Speller, R.

    2009-10-01

    Quantitative contrast-enhanced mammography, based on a dual-energy approach, aims to extract quantitative and temporal information of the tumour enhancement after administration of iodinated vascular contrast media. Simulations using analytical expressions and optimization of critical parameters essential for the development of quantitative contrast-enhanced mammography are presented. The procedure has been experimentally evaluated using a tissue-equivalent phantom and an amorphous silicon active matrix flat panel imager. The x-ray beams were produced by a tungsten target tube and spectrally shaped using readily available materials. Measurement of iodine projected thickness in mg cm-2 has been performed. The effect of beam hardening does not introduce nonlinearities in the measurement of iodine projected thickness for values of thicknesses found in clinical investigations. However, scattered radiation introduces significant deviations from slope equal to unity when compared with the actual iodine projected thickness. Scatter correction before the analysis of the dual-energy images provides accurate iodine projected thickness measurements. At 10% of the exposure used in clinical mammography, signal-to-noise ratios in excess of 5 were achieved for iodine projected thicknesses less than 3 mg cm-2 within a 4 cm thick phantom. For the extraction of temporal information, a limited number of low-dose images were used with the phantom incorporating a flow of iodinated contrast medium. The results suggest that spatial and temporal information of iodinated contrast media can be used to indirectly measure the tumour microvessel density and determine its uptake and washout from breast tumours. The proposed method can significantly improve tumour detection in dense breasts. Its application to perform in situ x-ray biopsy and assessment of the oncolytic effect of anticancer agents is foreseeable.

  3. No detectable nephrotoxic side effect using a dimer, non-ionic contrast media in cerebral perfusion computed tomography in case of suspected brain ischemia

    International Nuclear Information System (INIS)

    Petrik, M.; Weigel, C.; Kirsch, M.; Hosten, N.

    2005-01-01

    Purpose: In suspected brain ischemia, the perfusion cerebral computed tomography (cCT) should be performed with the lowest amount of contrast media to avoid a contrast media induced nephropathy (CIN) even if the patient already is in renal failure. We were interested to find the best parameters for this examination. Material and methods: From February 2000 to March 2003, 138 patients (58 females, 80 males, mean age 66.8 years) underwent cCT-perfusion immediately after the admission to our stroke unit. Of these patients, 62% (n=86) had normal renal function and 38% (n=52) renal failure (up to 381 μmol/l basic serum creatinine). We varied volume (20-80 ml), flow (5 vs. 7.2. ml/s) and concentration (270 vs. 320 ml/mg iodine) of a dimer, non-ionic contrast media (Visipaque registered ) to establish 5 groups. So we got patients receiving 6 g, 12 g, 16 g, 19 g and 25 g of iodine. After generating the perfusion maps, two radiologists reviewed the quality of the maps and scored it (1-5). We measured the serum creatinine before contrast application and at follow up cCt (days 3 and 7). Results: The quality of the maps increases with increasing amount of iodine. However, the diagnostic result was not significantly better using more than about 16 g of iodine (e.g., 60 ml-7.2 ml/s - 270 mg/ml) in cCT-perfusion studies. Only one patient had a pathologic increase in serum creatinine (day 1: 93; day 4: 146 μmol/l) but died at day 5 because of massive co-morbidity and septic pneumonia. No CIN occurred even in the patient group with pre-existent renal failure. Conclusions: About 60 ml contrast media and a moderate flow rate of about 7 ml/s ensure good results in perfusion-cCT, even if the patients have poor blood circulation or arteriosclerosis. The use of a dimer, non-ionic contrast media (range of 6-25 g iodine) seems to minimize the risk of CIN in the daily routine. (orig.)

  4. Dual Energy CT Angiography of Peripheral Arterial Disease: Feasibility of Using Lower Contrast Medium Volume.

    Directory of Open Access Journals (Sweden)

    Abdulrahman Almutairi

    Full Text Available One of the main drawbacks associated with Dual Energy Computed Tomography Angiography (DECTA is the risk of developing contrast medium-induced nephropathy (CIN. The aim of the present study was firstly, to design an optimal CT imaging protocol by determining the feasibility of using a reduced contrast medium volume in peripheral arterial DECTA, and secondly, to compare the results with those obtained from using routine contrast medium volume.Thirty four patients underwent DECTA for the diagnosis of peripheral arterial disease. They were randomly divided into two groups: Group 1 (routine contrast volume group with n = 17, injection rate 4-5 ml/s, and 1.5 ml/kg of contrast medium, and Group 2 ((low contrast volume group, with n = 17, injection rate 4-5ml/s, and contrast medium volume 0.75 ml/kg. A fast kilovoltage-switching 64-slice CT scanner in the dual-energy mode was employed for the study. A total of 6 datasets of monochromatic images at 50, 55, 60, 65, 70 and 75 keV levels were reconstructed with adaptive statistical iterative reconstruction (ASIR at 50%. A 4-point scale was the tool for qualitative analysis of results. The two groups were compared and assessed quantitatively for image quality on the basis of signal-to-noise ratio (SNR and contrast-to-noise-ratio (CNR. Radiation and contrast medium doses were also compared.The overall mean CT attenuation and mean noise for all lower extremity body parts was significantly lower for the low volume contrast group (p<0.001, and varied significantly between groups (p = 0.001, body parts (p<0.001 and keVs (p<0.001. The interaction between group body parts was significant with CT attenuation and CNR (p = 0.002 and 0.003 respectively, and marginally significant with SNR (p = 0.047, with minimal changes noticed between the two groups. Group 2 (low contrast volume group displayed the lowest image noise between 65 and 70 keV, recorded the highest SNR and CNR at 65 keV, and produced significantly lower

  5. Controlled synthesis of La{sub 1−x}Sr{sub x}CrO{sub 3} nanoparticles by hydrothermal method with nonionic surfactant and their ORR activity in alkaline medium

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Bo Hyun; Park, Shin-Ae [Energy System Major, School of Mechanical Engineering, Pusan National University, Busan 609-735 (Korea, Republic of); Park, Bong Kyu [GIFT Center, Pusan National University, Busan, 609-735 (Korea, Republic of); Chun, Ho Hwan, E-mail: chunahh@pusan.ac.kr [Global Core Research Center for Ships and Offshore Plants(GCRC-SOP), Pusan National University, Busan, 609-735 (Korea, Republic of); Kim, Yong-Tae, E-mail: yongtae@pusan.ac.kr [Energy System Major, School of Mechanical Engineering, Pusan National University, Busan 609-735 (Korea, Republic of)

    2013-10-15

    Graphical abstract: We demonstrate that Sr-doped LaCrO{sub 3} nanoparticles were successfully prepared by the hydrothermal synthesis method using the nonionic surfactant Triton X-100 and the applicability of La{sub 1−x}Sr{sub x}CrO{sub 3} to oxygen reduction reaction (ORR) electrocatalysis in an alkaline medium. Compared with the nanoparticles synthesized by the coprecipitation method, they showed enhanced ORR activity. - Highlights: • Sr-doped LaCrO{sub 3} nanoparticles were successfully prepared by the hydrothermal method using the nonionic surfactant. • Homogeneously shaped and sized Sr-doped LaCrO{sub 3} nanoparticles were readily obtained. • Compared with the nanoparticles synthesized by the coprecipitation method, they showed an enhanced ORR activity. • The main origin was revealed to be the decreased particle size due to the nonionic surfactant. - Abstract: Sr-doped LaCrO{sub 3} nanoparticles were prepared by the hydrothermal method with the nonionic surfactant Triton X-100 followed by heat treatment at 1000 °C for 10 h. The obtained perovskite nanoparticles had smaller particle size (about 100 nm) and more uniform size distribution than those synthesized by the conventional coprecipitation method. On the other hand, it was identified with the material simulation that the electronic structure change by Sr doping was negligible, because the initially unfilled e{sub g}-band was not affected by the p-type doping. Finally, the perovskite nanoparticles synthesized by hydrothermal method showed much higher ORR activity by over 200% at 0.8 V vs. RHE than those by coprecipitation method.

  6. Contrast-enhanced angiographic cone-beam computed tomography without pre-diluted contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Jo, K.I.; Kim, S.R.; Choi, J.H.; Kim, K.H.; Jeon, P. [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Gangnam-gu, Seoul (Korea, Republic of)

    2015-11-15

    Contrast-enhanced cone-beam computed tomography (CBCT) has been introduced and accepted as a useful technique to evaluate delicate vascular anatomy and neurovascular stents. Current protocol for CBCT requires quantitative dilution of contrast medium to obtain adequate quality images. Here, we introduce simple methods to obtain contrast-enhanced CBCT without quantitative contrast dilution. A simple experiment was performed to estimate the change in flow rate in the internal carotid artery during the procedure. Transcranial doppler (TCD) was used to evaluate the velocity change before and after catheterization and fluid infusion. In addition, 0.3 cm{sup 3}/s (n = 3) and 0.2 cm{sup 3}/s (n = 7) contrast infusions were injected and followed by saline flushes using a 300 mmHg pressure bag to evaluate neurovascular stent and host arteries. Flow velocities changed -15 ± 6.8 % and +17 ± 5.5 % from baseline during catheterization and guiding catheter flushing with a 300 mmHg pressure bag, respectively. Evaluation of the stents and vascular structure was feasible using this technique in all patients. Quality assessment showed that the 0.2 cm{sup 3}/s contrast infusion protocol was better for evaluating the stent and host artery. Contrast-enhanced CBCT can be performed without quantitative contrast dilution. Adequate contrast dilution can be achieved with a small saline flush and normal blood flow. (orig.)

  7. Power port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study.

    Science.gov (United States)

    Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Royon, Laurent; Marcy, Pierre Yves; Merckx, Jacques

    2013-01-01

    The use of totally implantable venous access devices (TIVADs) certified as "high pressure resistant" or "power port" has begun to spread worldwide as a safe procedure for power contrast injection. Owing to the thermo-rheological properties of the contrast media, the primary aim of this work is to present an in vitro experimental impact study concerning the impact of the temperature level on flushing efficiency after contrast medium injection. Moreover, we report experimental data that confirms the role of needle bevel orientation. The secondary aim is to answer the following questions: Is there significant device contrast medium trapping after contrast medium injection? Is saline flushing efficient? And, finally, is it safe to inject contrast medium through an indwelled port catheter? The experimental results show that in addition to hydrodynamics, temperature is a key parameter for the efficiency of device flushing after contrast medium injection. It appears that this is the case when the cavity is incompletely rinsed after three calibrated flushing volumes of 10 mL saline solution, even by using the Huber needle bevel opposite to the port exit. This leads to a potentially important trapped volume of contrast medium in the port, and consequently to the possibility of subsequent salt precipitates and long term trisubstituted benzene nuclei delivery that might impair the solute properties, which may be further injected via the power port later on. We thus suggest, in TIVADS patients, the use of a temporary supplementary intravenous line rather than the port to perform contrast medium injections in daily radiology routine practice.

  8. Preparation of Organized Mesoporous Silica from Sodium Metasilicate Solutions in Alkaline Medium using Nonionic Surfactants

    Czech Academy of Sciences Publication Activity Database

    Zukalová, Markéta; Rathouský, Jiří; Zukal, Arnošt

    2003-01-01

    Roč. 68, č. 10 (2003), s. 2019-2031 ISSN 0010-0765 Institutional research plan: CEZ:AV0Z4040901 Keywords : mesoporous SiO2 * sodium metasilicate * nonionic surfactants Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.041, year: 2003

  9. Double blind evaluation of the effects of various contrast media on extremity veins in the dog

    International Nuclear Information System (INIS)

    Laerum, F.; Dehner, L.P.; Rysavy, J.; Amplatz, K.; Minnesota Univ., Minneapolis

    1987-01-01

    Canine superficial extremity veins were examined grossly and microscopically in a double blind fashion for endothelial damage and phlebitis one hour and four days after the injection of ionic monomeric or dimeric, and non-ionic monomeric, 300 mg I/ml, contrast media. Superficial veins of all four extremities and the tail vein were injected with the same amounts of contrast medium after application of tourniquets for 20 minutes following the injections. Silver staining and prefixation of the veins were done in situ. The specimens were evaluated together with cross-sectioned, hematoxylin-eosin stained biopsies. On the basis of a randomized study of 77 dogs, endothelial damage or thrombosis caused by various contrast media as seen in man was not demonstrated. This may be due to species differences. It is postulated that canine endothelium may have a higher resistance to contrast medium injury than human endothelium. (orig.)

  10. Oral contrast medium in PET/CT: should you or shouldn't you?

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Dickson, John C.; Townsend, Caroline; Croasdale, Ian; Syed, Rizwan; Nagabushan, Nagesh; Hain, Sharon F.; Ell, Peter J.; Bomanji, Jamshed B.

    2005-01-01

    It has been suggested that the use of computed tomography (CT) positive contrast agents has led to attenuation-induced artefacts on 18 F-fluorodeoxyglucose positron emission tomography ( 18 F-FDG PET/CT) systems. Consequently, centres may withhold the use of such agents. Whilst there is theoretical evidence to support the aforementioned claim, the clinical relevance of the induced artefacts has not been widely established. Moreover, the potential benefits of bowel enhancement on PET/CT have yet to be formally evaluated. We therefore prospectively examined PET/CT studies to assess whether the use of oral contrast medium induces clinically relevant artefacts and whether the use of these agents is diagnostically helpful. Over a 2-month period, 18 F-FDG PET/CT images were prospectively reviewed from 200 patients following Gastrografin administration 2 h prior to examination. Both a radiologist and a nuclear medicine physician reviewed the images for contrast medium-mediated clinically relevant artefacts. Artefacts were sought on the CT attenuation-corrected images and were compared with the appearance on non-attenuated-corrected images. The number of examinations in which the oral contrast aided image interpretation was also noted. There were no oral contrast medium-induced clinically significant artefacts. In 38 of the 200 patients, oral contrast aided image interpretation (owing to differentiation of mass/node from bowel, discrimination of intestinal wall from lumen or definition of the anatomy of a relevant site). In 33 of these 38 patients, the anatomical site of interest was the abdomen/pelvis. The use of oral contrast medium in 18 F-FDG PET studies should not be withheld as it improves image interpretation and does not produce clinically significant artefacts. (orig.)

  11. Power port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study

    Directory of Open Access Journals (Sweden)

    Guiffant G

    2013-09-01

    Full Text Available Gérard Guiffant,1 Jean Jacques Durussel,1 Patrice Flaud,1 Laurent Royon,1 Pierre Yves Marcy,2 Jacques Merckx1,31University Paris Diderot, Paris, France; 2Radiodiagnosis and Interventional Radiology Department, Caen, France; 3University Teaching Hospital Necker-Enfants Malades, Paris, FrancePurpose: The use of totally implantable venous access devices (TIVADs certified as "high pressure resistant" or "power port" has begun to spread worldwide as a safe procedure for power contrast injection. Owing to the thermo-rheological properties of the contrast media, the primary aim of this work is to present an in vitro experimental impact study concerning the impact of the temperature level on flushing efficiency after contrast medium injection. Moreover, we report experimental data that confirms the role of needle bevel orientation. The secondary aim is to answer the following questions: Is there significant device contrast medium trapping after contrast medium injection? Is saline flushing efficient? And, finally, is it safe to inject contrast medium through an indwelled port catheter?Results: The experimental results show that in addition to hydrodynamics, temperature is a key parameter for the efficiency of device flushing after contrast medium injection. It appears that this is the case when the cavity is incompletely rinsed after three calibrated flushing volumes of 10 mL saline solution, even by using the Huber needle bevel opposite to the port exit. This leads to a potentially important trapped volume of contrast medium in the port, and consequently to the possibility of subsequent salt precipitates and long term trisubstituted benzene nuclei delivery that might impair the solute properties, which may be further injected via the power port later on.Conclusion: We thus suggest, in TIVADS patients, the use of a temporary supplementary intravenous line rather than the port to perform contrast medium injections in daily radiology routine practice

  12. Estudo comparativo dos meios de contraste baritado e iodado-iônico e não-iônico no trato respiratório de ratos Comparative study of barium and iodine agents - ionic and nonionic on the respiratory tract of the rats

    Directory of Open Access Journals (Sweden)

    Maria de Lourdes Pessole Biondo-Simões

    2003-10-01

    determine the changes in the respiratory tract triggered by the presence of contrast medium. METHODS: Ninety-one rats were divided at random into 5 groups, i.e., an intact control group of 7 animals and 4 groups of 21 rats each. The manipulated control group received physiological saline and the experimental groups respectively received barium, ionic iodine and non-ionic iodine. Under anesthesia and direct visualization of the trachea, 0.75 ml/kg (0.25 ml of the contrast medium was injected into the animals of each group. The effects of the procedure were determined after 1 hour, 1 day and 1 week, with the animals being sacrificed at each time point by drawing lots. Radiographic documentation was obtained, followed by resection and histopathologic examination of the lungs. RESULTS: After 1 hour, the middle fields and the right upper field were involved in the group injected with barium. In the groups injected with ionic iodine and non-ionic iodine, the entire right lung was found to be opacified. After 1 day and 1 week, the groups injected with iodine were normal, whereas the group injected with barium showed involvement of the middle fields. After 1 week, histopathologic examination revealed that the group injected with barium exhibited large amounts of intra-alveolar, perivascular and peribronchial macrophages CONCLUSION: The ionic and non-ionic iodine contrast media led to temporary changes, whereas barium promoted a chronic inflammatory reaction with maintenance of radiographic translation.

  13. Use of cystatin C and serum creatinine for the diagnosis of contrast-induced nephropathy in patients undergoing contrast-enhanced computed tomography at an oncology centre.

    Directory of Open Access Journals (Sweden)

    Joao Italo Fortalesa Melo

    Full Text Available Our aim was to assess renal function using as laboratory measurements serum creatinine and cystatin C concentrations before and after administration of low-osmolarity (nonionic iodinated contrast medium in patients with cancer undergoing computed tomography (CT.This prospective study included 400 oncologic outpatients. Serum creatinine and cystatin C concentrations were measured before and 72 h after contrast administration. Glomerular filtration rates (GFRs were estimated using serum creatinine-based [Modification of Diet in Renal Disease (MDRD and Cockroft-Gault and cystatin C based (Larsson equations. Exploratory data analysis was performed. The nonparametric Wilcoxon test was used to compare pre and post contrast of test results and estimated clearance. The confidence interval used in the analysis was 95%.Compared with the pre-contrast values, the mean serum creatinine concentration was significantly higher and average GFRs estimated using MDRD and Cockcroft-Gault equations were significantly lower after the administration of contrast (p <0.001. It was also observed a significant increase after contrast in the concentration of Cystatin C (p = 0.015. In addition, a decrease in GFR estimated using the average Larsson (p = 0.021 was observed between time points. However, none of the patients presented clinically significant nephropathy.Assessment using serum creatinine and cystatin C concentrations showed changes in renal function among patients with cancer undergoing contrast-enhanced CT examination in this study. No significant renal damage related to the use of low-osmolarity iodinated contrast medium of the type and dosage employed in this study was observed. This contrast medium is thus safe for use in patients with cancer.

  14. Differences in phytotoxicity and dissipation between ionized and nonionized oil sands naphthenic acids in wetland plants.

    Science.gov (United States)

    Armstrong, Sarah A; Headley, John V; Peru, Kerry M; Germida, James J

    2009-10-01

    Naphthenic acids (NAs) are composed of alkyl-substituted acyclic and cycloaliphatic carboxylic acids and, because they are acutely toxic to fish, are of toxicological concern. During the caustic hot-water extraction of oil from the bitumen in oil sands deposits, NAs become concentrated in the resulting tailings pond water. The present study investigated if dissipation of NAs occurs in the presence of hydroponically grown emergent macrophytes (Typha latifolia, Phragmites australis, and Scirpus acutus) to determine the potential for phytoremediation of these compounds. Plants were grown with oil sands NAs (pKa approximately 5-6) in medium at pH 7.8 (predominantly ionized NAs) and pH 5.0 (predominantly nonionized NAs) to determine if, by altering their chemical form, NAs may be more accessible to plants and, thus, undergo increased dissipation. Whereas the oil sands NA mixture in its nonionized form was more toxic to wetland plants than its ionized form, neither form appeared to be sequestered by wetland plants. The present study demonstrated that plants may selectively enhance the dissipation of individual nonionized NA compounds, which contributes to toxicity reduction but does not translate into detectable total NA dissipation within experimental error and natural variation. Plants were able to reduce the toxicity of a NA system over 30 d, increasing the median lethal concentration (LC50; % of hydroponic solution) of the medium for Daphnia magna by 23.3% +/- 8.1% (mean +/- standard error; nonionized NAs) and 37.0% +/- 2.7% (ionized NAs) as determined by acute toxicity bioassays. This reduction in toxicity was 7.3% +/- 2.6% (nonionized NAs) and 45.0% +/- 6.8% (ionized NAs) greater than that in unplanted systems.

  15. Contrast-medium-induced nephropathy: is there a new consensus? A review of published guidelines

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.; Morcos, Sameh K.

    2006-01-01

    The interest in contrast-medium-induced nephropathy has increased considerably during the last few years. Various guidelines regarding identifying patients at risk and measures to reduce the incidence of this complication have been proposed. The aim of this review was to analyse whether there is some consistency amongst these guidelines. A Medline search for the keyword ''contrast medium induced nephropathy'' during the period from the beginning of 2003 through the end of September 2005 was carried out. Only papers in English were reviewed. Thirteen guidelines were identified. Inconsistency was observed regarding advise on the prophylactic use of drugs and the isoosmolar dimer to reduce the incidence of contrast-medium-induced nephropathy. Consistency was found in relation to the importance of hydration, cessation of intake of nephrotoxic drugs and administration of the lowest possible dose of contrast medium. No new consensus has been observed in comparison to the European Society for Urogenital Radiology (ESUR) guidelines, which were published in 1999. (orig.)

  16. Use of iohexol as a gastrointestinal contrast medium in the dog

    International Nuclear Information System (INIS)

    Agut, A.; Sanchez-Valverde, M.A.; Lasaosa, J.M.; Murciano, J.; Molina, F.

    1993-01-01

    Iohexol was administered orally in five dogs. The dose, gastrointestinal (GI) transit time, appearance of mucosal patterns and side effects were studied. Three different doses (525, 700, 875 mgI/kg) were used in each dog at 1-week intervals. GI transit time was rapid. In each dose, gastric emptying commenced immediately after administration of the contrast medium, and was completed within 30–60 min with doses of 525–700 mgI/kg and 90–120 min with 875 mgI/kg. Large intestinal filling was observed within 60-90 min. In the majority of studies, the mucosal border appeared as a thin homogeneous halo of lucency surrounding the more opaque bowel lumen contents. The contrast intensity was not adequate with the lowest dose. The image quality did not deteriorate along the GI tract. No adverse reactions were found. Iohexol is an alternative GI contrast medium in the dog when contrast media are contraindicated

  17. Non-Ionizing Radiation Used in Microwave Ovens

    Science.gov (United States)

    ... Non-Ionizing Radiation Used in Microwave Ovens Non-Ionizing Radiation Used in Microwave Ovens Explore the interactive, virtual ... can do Where to learn more About Non-Ionizing Radiation Used in Microwave Ovens Microwave Oven. Microwave ovens ...

  18. Ecotoxicological characterization of polyoxyethylene glycerol ester non-ionic surfactants and their mixtures with anionic and non-ionic surfactants.

    Science.gov (United States)

    Ríos, Francisco; Fernández-Arteaga, Alejandro; Lechuga, Manuela; Fernández-Serrano, Mercedes

    2017-04-01

    This paper reports on a study that investigated the aquatic toxicity of new non-ionic surfactants derived from renewable raw materials, polyoxyethylene glycerol ester (PGE), and their binary mixtures with anionic and non-ionic surfactants. Toxicity of pure PGEs was determined using representative organisms from different trophic levels: luminescent bacteria (Vibrio fischeri), microalgae (Pseudokirchneriella subcapitata), and freshwater crustaceans (Daphnia magna). Relationships between toxicity and the structural parameters such as unit of ethylene oxide (EO) and hydrophilic-lipophilic balance (HLB) were evaluated. Critical micellar concentration (CMC) in the conditions of the toxicity test was also determined. It was found that the toxicity of the aqueous solutions of PGE decreased when the number of EO units in the molecule, HLB, and CMC increased. PGEs showed lower CMC in marine medium, and the toxicity to V. ficheri is lower when the CMC was higher. Given their non-polar nature, narcosis was expected to be the primary mode of toxic action of PGEs. For the mixture of surfactants, we observed that the mixtures with PGE that had the higher numbers of EO units were more toxic than the aqueous solutions of pure surfactants. Moreover, we found that concentration addition was the type of action more likely to occur for mixtures of PGE with lower numbers of EO units with non-ionic surfactants (alkylpolyglucoside and fatty alcohol ethoxylate), whereas for the mixture of PGE with lower EO units and anionic surfactant (ether carboxylic derivative), the most common response type was response addition. In case of mixtures involving amphoteric surfactants and PGEs with the higher numbers of EO units, no clear pattern with regard to the mixture toxicity response type could be observed.

  19. Gadolinium-DTPA and gadodiamide as an alternative contrast medium for CT

    International Nuclear Information System (INIS)

    Engelbrecht, V.; Koch, J.A.; Rassek, M.; Moedder, U.

    1996-01-01

    To evaluate the effect of intravenously applied gadolinium-based contrast medium in computed tomographic (CT) studies. Serial dilutions of iohexol 300, Gd-DTPA and gadodiamide were scanned with CT in a phantom study using water filled tubes. For quantification of X-ray attenuation, the mean Hounsfield units (HU) were calculated from the CT scans. Five patients with contraindications against iodine contrast agents were examined with abdominal or thoracic CT before and after application of 0.2 mmol/kg body weight of a gadolinium-based contrast agent. In these patients attenuation values were obtained in ROI from unenhanced and enhanced CT scans. The phantom study revealed a 38,4% enhancement for Gd-DTPA and a 35.7% enhancement for gadodiamide scaled on the reference measurements with iohexol 300. Thus, 130.2 ml Gd-DTPA or 140.1 ml gadodiamide are needed to achieve the same attenuation as an i.v. injection of 50 ml iohexol 300. Consequently the corresponding dose of 1 mmol/kg body weight would exceed the manufacturer's recommended dose. In four patients with complete thoracic or abdominal CT, i.v. applied gadolinium-based contrast medium (0.2 mmol/kg) yielded no visible advantage. In these patients parenchymal enhancement did not exceed 25%. Dynamic CT of a patient with focal liver lesion revealed an arterial enhancement peak of 75%. Sufficient parenchymal enhancement in CT studies cannot be achieved with the available gadolinium-based contrast mediums. They might be helpful if only short time vascular enhancement is required. (orig.) [de

  20. CT contrasting theory. Effects of the concentration, volume and infusion rate of iodine contrast medium on TDC

    International Nuclear Information System (INIS)

    Yamachi, Jun

    2007-01-01

    This study was performed to evaluate the effects in the title on TDC (time-density curve) using a phantom. CT machine used was Toshiba Aquilion Multi 64, TDC phantom was the product of Nemoto-Kyorindo Co., and the contrast medium was Eisai iomeprol, in syringe-sealed formulations of 300 and 350 mg I/mL. The medium was infused at 1-5 mL/sec in the phantom equivalent to body weight of 78 kg (total water volume=1 min circulation=6,000 mL, 800 mL/heart) to obtain 30 TDCs. Evaluated were the relationships of the infusion rate (mL/sec), volume (mL) or time (sec) with TDC parameters of the detection time of the medium, slope, time to reach the maximum CT value, the maximum CT value, time to keep the CT concentration and its actual concentration. Results revealed that, regardless to the difference of formulations of the contrast medium, TDC with high reproducibility can be obtainable by making the infusion rate of I per unit time and body weight (mgI/sec/kg) constant when the infusion time is made identical for CT of the same diagnostic purpose. (R.T.)

  1. Craniopharyngiomas - the utility of contrast medium enhancement for MR imaging at 1.5 T

    International Nuclear Information System (INIS)

    Hald, J.K.; Eldevik, O.P.; Brunberg, J.A.; Chandler, W.F.

    1994-01-01

    To evaluate the efficacy of i.v. contrast medium administration in MR imaging at 1.5 T in patients with craniopharyngiomas, MR studies of 10 men and 6 women with pathologically proven craniopharyngiomas were made. The MR images were obtained as 3- to 5-mm-thick coronal (n=13) or axial (n=3) T1-weighted images (T1WI) prior to an following i.v. Gd-DTPA administration. Proton density-(PD) and T2-weighted images (T2WI) were also obtained. Conspicuity of tumor margins, cystic versus solid components, size, location and effect upon adjacent structures were separately characterized in all imaging sequences. In 6 patients contrast medium-enhanced T1WI, PD and T2WI demonstrated cystic tumor components not seen on unenhanced T1WI. There were significant differences (p<0.004) on 2-tailed Student's t-test comparing tumor conspicuity on contrast medium-enhanced T1WI with unenhanced T1WI, PD and T2WI. Optimal tumor delineation on MR imaging of patients with craniopharyngiomas justifies the use of i.v. contrast medium. (orig.)

  2. Adriamycin nephrosis and contrast media

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Golman, K.; Hemmingsen, L.; Larsen, S.; Skaarup, P.; Koebenhavns Amts Sygehus, Herlev; Koebenhavns Amts Sygehus, Herlev; Centralsygehuset, Nykoebing Falster; Malmoe Allmaenna Sjukhus

    1990-01-01

    Urine profiles (albumin, glucose, NAG, LDH, GGT and sodium) were followed for 9 days after intravenous injection of either diatrizoate, iohexol, or saline in 27 Wistar rats with nephrosis induced by Adriamycin 42 days before. Another 9 rats exposed to neither Adriamycin nor contrast media served as controls. None of the contrast media caused further increased albuminuria of significance, whereas both induced significantly increased excretion of all 5 tubular components. The excretion of NAG and sodium was significantly higher following diatrizoate than following iohexol. From 24 h post injection there was no significantly greater excretion of any of the components after either diatrizoate or iohexol than after saline among the rats given Adriamycin. At the end of day 9 after contrast medium injection neither serum sodium, potassium, glucose, urea, creatinine, nor albumin revealed any contrast media related changes. Kidney histology showed quantitatively larger lesions in kidneys exposed to Adriamycin and contrast media than in kidneys exposed to Adriamycin and saline. There were no differences between the two contrast media groups. It is thus concluded, that both high osmolar ionic and low osmolar non-ionic contrast media cause temporary tubular dysfunction but no further glomerular dysfunction in rats with nephrosis induced by Adriamycin. The histologic findings indicate that both media may worsen non-reversible renal lesions. (orig.)

  3. A method to evaluate the dose increase in CT with iodinated contrast medium

    International Nuclear Information System (INIS)

    Amato, Ernesto; Lizio, Domenico; Settineri, Nicola; Di Pasquale, Andrea; Salamone, Ignazio; Pandolfo, Ignazio

    2010-01-01

    Purpose: The objective of this study is to develop a method to calculate the relative dose increase when a computerized tomography scan (CT) is carried out after administration of iodinated contrast medium, with respect to the same CT scan in absence of contrast medium. Methods: A Monte Carlo simulation in GEANT4 of anthropomorphic neck and abdomen phantoms exposed to a simplified model of CT scanner was set up in order to calculate the increase of dose to thyroid, liver, spleen, kidneys, and pancreas as a function of the quantity of iodine accumulated; a series of experimental measurements of Hounsfield unit (HU) increment for known concentrations of iodinated contrast medium was carried out on a Siemens Sensation 16 CT scanner in order to obtain a relationship between the increment in HU and the relative dose increase in the organs studied. The authors applied such a method to calculate the average dose increase in three patients who underwent standard CT protocols consisting of one native scan in absence of contrast, followed by a contrast-enhanced scan in venous phase. Results: The authors validated their GEANT4 Monte Carlo simulation by comparing the resulting dose increases for iodine solutions in water with the ones presented in literature and with their experimental data obtained through a Roentgen therapy unit. The relative dose increases as a function of the iodine mass fraction accumulated and as a function of the Hounsfield unit increment between the contrast-enhanced scan and the native scan are presented. The data shown for the three patients exhibit an average relative dose increase between 22% for liver and 74% for kidneys; also, spleen (34%), pancreas (28%), and thyroid (48%) show a remarkable average increase. Conclusions: The method developed allows a simple evaluation of the dose increase when iodinated contrast medium is used in CT scans, basing on the increment in Hounsfield units observed on the patients' organs. Since many clinical protocols

  4. A method to evaluate the dose increase in CT with iodinated contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Amato, Ernesto; Lizio, Domenico; Settineri, Nicola; Di Pasquale, Andrea; Salamone, Ignazio; Pandolfo, Ignazio [Department of Radiological Sciences, University of Messina, Messina 98125 (Italy); Department of Physics, University of Messina, Messina 98166 (Italy); University Hospital ' ' G. Martino' ' , Messina 98125 (Italy); Department of Radiological Sciences, University of Messina, Messina 98125 (Italy) and University Hospital ' ' G. Martino' ' , Messina 98125 (Italy)

    2010-08-15

    Purpose: The objective of this study is to develop a method to calculate the relative dose increase when a computerized tomography scan (CT) is carried out after administration of iodinated contrast medium, with respect to the same CT scan in absence of contrast medium. Methods: A Monte Carlo simulation in GEANT4 of anthropomorphic neck and abdomen phantoms exposed to a simplified model of CT scanner was set up in order to calculate the increase of dose to thyroid, liver, spleen, kidneys, and pancreas as a function of the quantity of iodine accumulated; a series of experimental measurements of Hounsfield unit (HU) increment for known concentrations of iodinated contrast medium was carried out on a Siemens Sensation 16 CT scanner in order to obtain a relationship between the increment in HU and the relative dose increase in the organs studied. The authors applied such a method to calculate the average dose increase in three patients who underwent standard CT protocols consisting of one native scan in absence of contrast, followed by a contrast-enhanced scan in venous phase. Results: The authors validated their GEANT4 Monte Carlo simulation by comparing the resulting dose increases for iodine solutions in water with the ones presented in literature and with their experimental data obtained through a Roentgen therapy unit. The relative dose increases as a function of the iodine mass fraction accumulated and as a function of the Hounsfield unit increment between the contrast-enhanced scan and the native scan are presented. The data shown for the three patients exhibit an average relative dose increase between 22% for liver and 74% for kidneys; also, spleen (34%), pancreas (28%), and thyroid (48%) show a remarkable average increase. Conclusions: The method developed allows a simple evaluation of the dose increase when iodinated contrast medium is used in CT scans, basing on the increment in Hounsfield units observed on the patients' organs. Since many clinical

  5. Intravenous contrast medium application in elderly patients - evaluation of Iopentol (Imagopaque trademark 300)

    International Nuclear Information System (INIS)

    Rathsmann, P.; Jacobs, G.F.; Mueller, R.D.

    2004-01-01

    Purpose: We examined the subjective compatibility of elderly patients who received the intravenous contrast medium Iopentol (Imagopaque trademark 300). In addition, objective data were acquired to show possible interactions between contrast media and organ systems in old patients. Methods and materials: A CT scan with intravenous application of contrast media was performed on 132 patients ranging in age from 75 to 96 years. The patients were questioned about their individual sensations. In addition, blood pressure, creatinine and CT-densitometry were acquired as objective date. Results: The patients' individual sensations and clinical data show a very low rate of complications. Mild allergic reactions were noticed in two patients. No severe anaphylactic reactions were encountered. Statistically significant changes in blood pressure before and after administration of the contrast medium were not observed. The serum creatinine concentration was unchanged after application of contrast media. For CT-densitometry, the patients were divided into two groups, one group with patients 75-84 years and the other group with patients 85-96 years of age. CT-densitometry showed no age-related differences. The protocol of contrast administration resulted in excellent opacification of the examined regions, only the liver did not enhance in some cases before the opacification of the portal vein. Conclusion: It is shown that old age alone is no reason to withhold contrast media containing iodine when performing CT. For the evaluation of the liver, however, the peculiarities of old age have to be taken into account and the interval between injection of the contrast medium and beginning of the spiral-CT has to be extended. (orig.)

  6. Evaluation of the hemodynamic effects of intravenous administration of ionic and nonionic contrast materials: implications for deriving physiologic measurements from computed tomography and digital cardiovascular imaging

    International Nuclear Information System (INIS)

    Higgins, C.B.; Berber, K.H.; Mattrey, R.F.; Slutsky, R.A.

    1982-01-01

    The effects of intravenous injection of an ionic contrast material (Renografin-76 [meglumine sodium diatrizoate]) on left ventricular pressure, internal diameter, and wall thickness, and on coronary and femoral hemodynamics were compared with those of a hydrolytically stable nonionic contrast material (iohexol). Renografin-76 caused drastic biphasic changes in left ventricular pressure and dp/dt (rate of change of left ventricular pressure), and moderate changes in end systolic dimension. Iohexol caused little or no change in left ventricular pressure and dimensions. In addition, Renografin-76 caused marked arterial hypotension and large increases in coronary and femoral blood lows, while iohexol caused no significant change in arterial pressure and coronary blood flow, and a mild increase in femoral blood flow. Based on these findings, it is concluded that iohexol is preferable to standard ionic contrast material for deriving basal physiologic information from computed tomographic and digital vascular studies

  7. Soft-tissue tumor differentiation using 3D power Doppler ultrasonography with echo-contrast medium injection.

    Science.gov (United States)

    Chiou, Hong-Jen; Chou, Yi-Hong; Chen, Wei-Ming; Chen, Winby; Wang, Hsin-Kai; Chang, Cheng-Yen

    2010-12-01

    We aimed to evaluate the ability of 3-dimensional power Doppler ultrasonography to differentiate soft-tissue masses from blood flow and vascularization with contrast medium. Twenty-five patients (mean age, 44.1 years; range, 12-77 years) with a palpable mass were enrolled in this study. Volume data were acquired using linear and convex 3-dimensional probes and contrast medium injected manually by bolus. Data were stored and traced slice by slice for 12 slices. All patients were scanned by the same senior sonologist. The vascular index (VI), flow index (FI), and vascular-flow index (VFI) were automatically calculated after the tumor was completely traced. All tumors were later confirmed by pathology. The study included 8 benign (mean, 36.5 mL; range, 2.4-124 mL) and 17 malignant (mean, 319.4 mL; range, 9.9-1,179.6 mL) tumors. Before contrast medium injection, mean VI, FI and VFI were, respectively, 3.22, 32.26 and 1.07 in benign tumors, and 1.97, 29.33 and 0.67 in malignant tumors. After contrast medium injection, they were, respectively, 20.85, 37.33 and 8.52 in benign tumors, and 40.12, 41.21 and 17.77 in malignant tumors. The mean differences between with and without contrast injection for VI, FI and VFI were, respectively, 17.63, 5.07 and 7.45 in benign tumors, and 38.15, 11.88 and 16.55 in malignant tumors. Tumor volume, VI, FI and VFI were not significantly different between benign and malignant tumors before and after echo-contrast medium injection. However, VI, FI and VFI under self-differentiation (differences between with and without contrast injection) were significantly different between malignant and benign tumors. Three-dimensional power Doppler ultrasound is a valuable tool for differential diagnosis of soft-tissue tumors, especially with the injection of an echo-contrast medium. Copyright © 2010 Elsevier. Published by Elsevier B.V. All rights reserved.

  8. Optical tracking of contrast medium bolus to optimize bolus shape and timing in dynamic computed tomography

    International Nuclear Information System (INIS)

    Eisa, Fabian; Brauweiler, Robert; Peetz, Alexander; Hupfer, Martin; Nowak, Tristan; Kalender, Willi A

    2012-01-01

    One of the biggest challenges in dynamic contrast-enhanced CT is the optimal synchronization of scan start and duration with contrast medium administration in order to optimize image contrast and to reduce the amount of contrast medium. We present a new optically based approach, which was developed to investigate and optimize bolus timing and shape. The time-concentration curve of an intravenously injected test bolus of a dye is measured in peripheral vessels with an optical sensor prior to the diagnostic CT scan. The curves can be used to assess bolus shapes as a function of injection protocols and to determine contrast medium arrival times. Preliminary results for phantom and animal experiments showed the expected linear behavior between dye concentration and absorption. The kinetics of the dye was compared to iodinated contrast medium and was found to be in good agreement. The contrast enhancement curves were reliably detected in three mice with individual bolus shapes and delay times of 2.1, 3.5 and 6.1 s, respectively. The optical sensor appears to be a promising approach to optimize injection protocols and contrast enhancement timing and is applicable to all modalities without implying any additional radiation dose. Clinical tests are still necessary. (note)

  9. Utility of gadolinium as a contrast medium in endovascular therapeutic procedures; Utilidad del gadolinio como medio de contraste en procedimientos terapeuticos endovasculares

    Energy Technology Data Exchange (ETDEWEB)

    Reyes, R.; Pardo, M. D.; Gorriz, E.; Gallardo, L. (Hospital de Gran Canaria Dr. Negrin); Carreira, J. M. (Universidad de Santiago de Compostela)

    2001-07-01

    To assess the utility of gadolinium associated with CO{sub 2}, as a contrast medium in angiographic studies related to endovascular therapeutic procedures in patients with suboptimal renal function. Between January 2000 and June 2001, endovascular treatments using CO{sub 2} and gadolinium as contrast medium were performed in 10 patients presenting renal function deterioration (creatinine>1.5 mg/ml). A mean dose of 42 ml of gadolinium was administered. The images acquired in diagnostic and therapeutic studied were satisfactory in every case. There was no evidence of significant increases in the previous urea and creatine levels when measured 24, 48 and 72 hours after the procedure. In combination with CO{sub 2} gadolinium is a useful contrast medium for endovascular therapeutic procedures in patients with suboptimal renal function. (Author) 21 refs.

  10. Aspiration of barium contrast medium in an elderly man with disordered swallowing

    OpenAIRE

    Bağcı Ceyhan, B.; Çelikel, T.; Koç, M.; Ahıskalı, R.; Biren, T.; Ataizi Çelikel, Ç.

    1995-01-01

    The aspiration of contrast medium during the investigation of gastrointestinal diseases is a well recognized hazard, particularly in patients with swallowing disorders. A case is reported in which accidental aspiration of contrast barium occurred owing to disordered swallowing in an elderly man. The infiltration on chest x-ray persisted 2 years after barium contrast aspiration. Inflammatory reaction and retractile, granular material observed in lung biopsy specimens suggested barium-induced p...

  11. Intravenous administration of iodinated, non-ionic, low or isoosmolar contrast media: safety aspects; Intravenoese Anwendung von jodiertem, nichtionischem, nieder- bis isoosmolarem Kontrastmittel: Sicherheitsaspekte

    Energy Technology Data Exchange (ETDEWEB)

    Metz-Schimmerl, S.; Metz, V.; Schima, W.; Herold, C. [Universitaetsklinik fuer Radiodiagnostik und Ludwig Boltzmann-Institut fuer Klinische und Experimentelle Radiologie, Wien (Austria); Domanovits, H. [Universitaetsklinik fuer Notfallmedizin Wien, Wien (Austria)

    2002-01-01

    It iss the purpose of this review to provide information about the safe use of intravenously administered, iodinated, non-ionic, low or isoosmolar contrast media for radiological examinations, how to avoid adverse events, and how to react professionally in case of an anaphylactic reaction. Methods of prophylaxis and therapy for anaphylactic and chemotoxic effects of contrast media administration as well as absolute and relative contraindications are discussed. Medico-legal considerations of contrast agent administration, informed consent of patients, and methods of risk management for undesired contrast media reactions are considered in this article. Establishment of administration standards for contrast media is of tremendous importance to standardize radiological procedures. This basic radiological documentation is part of the institutional and individual legal safety management. (orig.) [German] Ziel dieses Artikels ist es, Kenntnisse zur sicheren Anwendung von intravenoes applizierten, jodierten, nichtionischen, nieder- bis isoosmolaren Roentgen-Kontrastmitteln zu vermitteln, um bei deren Verwendung unerwuenschte Wirkungen zu vermeiden oder im Falle eines anaphylaktischen Kontrastmittelzwischenfalls rasch und effektiv zu handeln. Neben Methoden der Verhuetung und Behandlung anaphylaktischer und chemotoxischer Wirkungen der Kontrastmittelgabe werden Einschraenkungen der Anwendung bei unterschiedlichen klinischen Bildern eroertert. Rechtliche Ueberlegungen zur Kontrastmittelanwendung, das Aufklaerungsgespraech und Praeventivmassnahmen zum Risiko-Management unerwuenschter Kontrastmittelwirkungen sind beruecksichtigt. Die Festlegung von Anwendungstandards fuer Kontrastmittel dient der Normierung medizinischen Vorgehens. Eine solche radiologische Basisdokumentation ist teil der institutionellen und individuellen rechtlichen Absicherung. (orig.)

  12. Extravasation of contrast medium into the gastrointestinal tract following lymphangiography

    International Nuclear Information System (INIS)

    Mihara, K.; Koga, K.; Tsurudome, H.; Nakano, T.; Hoshi, H.; Yamada, H.; Kawahira, K.; Inakura, M.; Watanabe, K.; Haraguchi, Y.

    1981-01-01

    Two cases with roentgenologic findings of extravasation of contrast medium into the stomach and colon following lymphangiography are presented. One is clinically diagnosed as primary intestinal lymphangiectasia; the other as retroperitoneal spread from uterine cancer. The significance of lymphangiography in gastrointestinal or retroperitoneal disorders is discussed. (orig.)

  13. Extravasation of contrast medium into the gastrointestinal tract following lymphangiography

    Energy Technology Data Exchange (ETDEWEB)

    Mihara, K.; Koga, K.; Tsurudome, H.; Nakano, T.; Hoshi, H.; Yamada, H.; Kawahira, K.; Inakura, M.; Watanabe, K.; Haraguchi, Y.

    1981-07-15

    Two cases with roentgenologic findings of extravasation of contrast medium into the stomach and colon following lymphangiography are presented. One is clinically diagnosed as primary intestinal lymphangiectasia; the other as retroperitoneal spread from uterine cancer. The significance of lymphangiography in gastrointestinal or retroperitoneal disorders is discussed.

  14. Non-ionizing radiation

    International Nuclear Information System (INIS)

    Fischer, P.G.

    1983-01-01

    The still growing use of non-ionizing radiation such as ultraviolet radiation laser light, ultrasound and infrasound, has induced growing interest in the effects of these types of radiation on the human organism, and in probable hazards emanating from their application. As there are up to now no generally approved regulations or standards governing the use of non-ionizing radiation and the prevention of damage, it is up to the manufacturers of the relevant equipment to provide for safety in the use of their apparatus. This situation has led to a feeling of incertainty among manufacturers, as to how which kind of damage should be avoided. Practice has shown that there is a demand for guidelines stating limiting values, for measuring techniques clearly indicating safety thresholds, and for safety rules providing for safe handling. The task group 'Non-ionizing radiation' of the Radiation Protection Association started a programme to fulfill this task. Experts interested in this work have been invited to exchange their knowledge and experience in this field, and a collection of loose leaves will soon be published giving information and recommendations. (orig./HP) [de

  15. Magnetic resonance tomography of the orbit: First experiences with the paramagnetic contrast medium gadolinium-DTPA

    International Nuclear Information System (INIS)

    Markl, A.; Vogl, T.; Scheidhauer, K.; Riedel, K.G.; Oeckler, R.

    1986-01-01

    In 21 patients with orbital mass lesions MRI was performed before and after administration of paramagnetic contrast medium, gadolinium-DPTA. In comparison to the plain scan the differentiation of the tumorous tissue against the surrounding structures was improved after application of contrast medium despite a partially moderate increase in signal intensity. Especially highly vascular tumors and vessel diseases show a significant contrast enhancement. With increasing experience in larger number of patients a tissue differentiation seems to be possible. (orig.) [de

  16. Stability of iodinated contrast media in UV-laser irradiation and toxicity of photoproducts

    International Nuclear Information System (INIS)

    Groenewaeller, E.F.; Kehlbach, R.; Claussen, C.D.; Duda, S.H.; Wahl, H.G.; Rodemann, H.P.

    1998-01-01

    Purpose: In XeCl-Excimer laser angioplasty, unintended and possibly harmful interaction of the UV-laser light and the contrast media may occur due to the high concentration of contrast medium proximal to the occlusion or subtotal stenosis. Methods: One ml of three nonionic monomeric contrast agents (iopromide, iomeprol, iopamidol), one nonionic dimetric (jotrolane), and one ionic monomeric (amidotrizoate) X-ray contrast agent were irradiated with a XeCl excimer laser (λ=308 nm, pulse duration 120 ns, 50 Hz) using a 9 French multifiber catheter (12 sectors). Up to 20 000 pulses (106 J) were applied. Using high performance liquid chromatography the amount of liberated iodide as well as the fraction of unchanged contrast media were measured. Cytotoxicity of the photoproducts was tested in a colony formation assay of human skin fibroblasts. The contrast agents were irradiated with 2000 pulses/ml (5.3 mJ/pulse; 10.6 J) and then added to the cell cultures for a period of three hours in a concentration of 10%. Results: Excimer laser irradiation induced iodide liberation of up to 3.3 mg iodide/ml. Up to 19% of the contrast agents changed their original molecular structure. Incubation of irradiated contrast agents resulted in a significantly decreased potential for colony formation (p values ranging from 0.0044 to 0.0102) with significantly higher toxicity of amidotrizoate and iomeprol in comparison to iopromide, iotrolan, and iopamidol. Discussion: Due to the cytotoxic photoproducts and the high level of liberated iodide, it is recommended to flush the artery with physiological saline solution before applying a pulsed excimer laser in human arterial obstructions in order to reduce the contrast agent concentration at the site of irradiation. (orig.) [de

  17. Extracellular gadolinium contrast agents: Differences in stability

    International Nuclear Information System (INIS)

    Morcos, S.K.

    2008-01-01

    Extracellular gadolinium contrast agents (Gd-CA) are either linear or macrocyclic chelates available as ionic or non-ionic preparations. The molecular structure whether cyclic or linear and ionicity determines the stability of Gd-CA. Linear chelates are flexible open chains which do not offer a strong binding to Gd 3+ . In contrast, the macrocyclic chelates offer a strong binding to Gd 3+ by the virtue of being preorganized rigid rings of almost optimal size to cage the gadolinium atom. Non-ionic preparations are also less stable in comparison to the ionic ones as the binding between Gd 3+ with the negatively charged carboxyl groups is stronger in comparison to that with amides or alcohol in the non-ionic preparations. According to stability constants and kinetic measurements, the most stable Gd-CM is the ionic-macrocyclic chelate Gd-DOTA and the least stable agents are the non-ionic linear chelates gadodiamide and gadoversetamide. In vivo data confirmed the low stability of non-ionic linear chelates but no significant difference was observed amongst the macrocyclic agents whether ionic (Gd-DOTA) or non-ionic such as Gd-HP-DO3A and Gd-BT-DO3A. The stability of Gd-CA seems to be an important factor in the pathogenesis of the serious complication of nephrogenic systemic fibrosis. Gd-CA of low stability are likely to undergo transmetallation and release free Gd ions that deposit in tissue and attract circulating fibrocytes to initiate the process of fibrosis. No cases of NSF have been observed so far after the exclusive use of the stable macrocyclic Gd-CA

  18. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is an x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  19. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is a x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  20. An experimental study on radiological examination of obstructed small bowel with various contrast media

    International Nuclear Information System (INIS)

    Lee, Yong; Kim, Sung Jin; Han, Moon Hee; Park, Jae Hyung

    1991-01-01

    For the evaluation of the level and cause of small bowel obstruction, an oral barium study is usually chosen. When perforation is whether barium or a water-soluble contrast agent should be used, because barium causes from foreign body reactions as well as adhesions in the extraluminal tissues. Water-soluble contrast agent, on the other hand, are less satisfactory but in general have no untoward effects in the extraluminal tissues. Because of hyperosomolarity, water-soluble contrast agents attract large amounts of fluid with subsequent dilution and loss of contrast and pose a risk of pulmonary edema if aspirated. The use of the newer non-ionic and low-osmolarity water-soluble contrast will likely avoid pulmonary complications due to aspiration. The author performed this experimental study to compare the radiological efficacy of different contrast media in enteric follow-through examinations of obstructed small bowel. Rate had a ligature applied to the distal ileum via laparotomy. Four contrast media were subjected to testing by instillation via oro-gastric tube immediately after laparotomy. Radiographs were exposed at 1, 4 and 8 hours and evaluated later. After 24 hours the animals were sacrificed and the stomach and small bowels, free from mesentery and omental tissue, were weighted with contrasts. The progression in the bowel was proportionate to the osmolarity of the contrast media. After 1 hour, the observations indicated sodium diatrizoate (Gastrografin, Schering) to be the least favorable medium with respect to sharpness of the mucosal border. After 8 hours, barium gave a poorer delineation compared to Ioxaglate (Hexabric, Guerbet) and Iopromide (Ultravist, Schering). Early deaths were noted in the sodium diatrizoate and ioxaglate groups. So we conclude that when using a rather high-volume bolus, low-osmolar non-ionic contrast media seem to have significant prospects for general diagnostic use in patients with suspected intestinal obstruction

  1. Radiologic diagnosis of gastro-oesophageal reflux. Comparison of barium and low-density contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, S.G.; Soekjer, H.; Johansson, K.E.; Tibbling, L.

    It has been proposed that the high density of ordinary barium suspension may complicate the radiologic diagnosis of gastro-oesophageal reflux. For this reason P-contrast was developed (Ferring AB); a contrast medium with the same density as water (1 g/cm/sup 3/). A comparison of P-contrast and barium (Mixobar Ventrikel 400 mg/ml) was performed in 82 patients. All patients were examined with both contrast media and the findings were compared with those at reflux test at manometry, endoscopy and 24-hour pH monitoring. Another 40 patients and 15 symptom-free controls were examined with two different amounts of barium, 100 ml and 200 ml, to study if the radiologic diagnosis of reflux varied with the volume of contrast medium administered. P-contrast was found to have no advantages over barium for the diagnosis of gastro-oesophageal reflux. The outcome of the radiologic examination was not influenced by the different volumes of barium used.

  2. Influence of MRI contrast media on histamine release from mast cells.

    Science.gov (United States)

    Kun, Tomasz; Jakubowski, Lucjusz

    2012-07-01

    Mast cells, owing to diversity of secreted mediators, play a crucial role in the regulation of inflammatory response. Together with basophils, mast cells constitute a central pathogenetic element of anaphylactic (IgE-dependent) and anaphylactoid (IgE-independent) reactions. In severe cases, generalized degranulation of mast cells may cause symptoms of anaphylactic shock. The influence of the classical, iodine-based contrast media on mastocyte degranulation has been fully described. Our objective was to determine the influence of the gadolinium-based MRI contrast media on histamine release from mast cells and to compare the activity of ionic and non-ionic preparations of contrast media. To determine the intensity of mast cell degranulation, we used an experimental model based on mastocytes isolated from rat peritoneal fluid. Purified suspensions of mast cells were incubated with various concentrations of Gd-DTPA and Gd-DTPA-BMA, and solutions of PEG 600 which served as a non-toxic osmotic stimulus. The intensity of mast cell activation was presented as mean percentage of histamine released from cells after incubation. The obtained results demonstrate that both ionic and non-ionic preparations of the MRI contrast media are able to induce mast cell degranulation in vitro. It was also proved that the non-ionic MRI contrast media stimulate mast cells markedly more weakly than ionic contrast media at identical concentration. The aforementioned results may suggest a more profitable safety profile of the non-ionic contrast preparations. We may also conclude that triggering of mast cell degranulation after incubation with the solutions of MRI contrast media results from non-specific osmotic stimulation and direct toxicity of free ionic residues.

  3. Influence of MRI contrast media on histamine release from mast cells

    International Nuclear Information System (INIS)

    Kun, Tomasz; Jakubowski, Lucjusz

    2012-01-01

    Mast cells, owing to diversity of secreted mediators, play a crucial role in the regulation of inflammatory response. Together with basophils, mast cells constitute a central pathogenetic element of anaphylactic (IgE-dependent) and anaphylactoid (IgE-independent) reactions. In severe cases, generalized degranulation of mast cells may cause symptoms of anaphylactic shock. The influence of the classical, iodine-based contrast media on mastocyte degranulation has been fully described. Our objective was to determine the influence of the gadolinium-based MRI contrast media on histamine release from mast cells and to compare the activity of ionic and non-ionic preparations of contrast media. To determine the intensity of mast cell degranulation, we used an experimental model based on mastocytes isolated from rat peritoneal fluid. Purified suspensions of mast cells were incubated with various concentrations of Gd-DTPA and Gd-DTPA-BMA, and solutions of PEG 600 which served as a non-toxic osmotic stimulus. The intensity of mast cell activation was presented as mean percentage of histamine released from cells after incubation. The obtained results demonstrate that both ionic and non-ionic preparations of the MRI contrast media are able to induce mast cell degranulation in vitro. It was also proved that the non-ionic MRI contrast media stimulate mast cells markedly more weakly than ionic contrast media at identical concentration. The aforementioned results may suggest a more profitable safety profile of the non-ionic contrast preparations. We may also conclude that triggering of mast cell degranulation after incubation with the solutions of MRI contrast media results from non-specific osmotic stimulation and direct toxicity of free ionic residues

  4. Gadolinium-DTPA (Magnevist) as a contrast medium for arterial DSA

    International Nuclear Information System (INIS)

    Schild, H.H.; Weber, W.; Boeck, E.; Mildenberger, P.; Strunk, H.; Dueber, C.; Grebe, P.; Schadmand-Fischer, S.; Thelen, M.

    1994-01-01

    16 DSA investigations using intra-arterial Gd-DTPA were performed on 12 patients. The contrast medium was administered either as a 0.5 molar gadolinium solution (commercially available) or diluted with distilled water to a 0.2 -0.4 molar gadolinium solution. The injection was made either by pressure injector or by hand. The aortic arch, abdominal aorta and pelvic and lower limb arteries were examined. 14 of the 16 procedures were diagnostically adequate, but compared with iodinated contrast materials, contrast was less marked. There were no cardiovascular, neurological or allergic side effects. Three patients suffered a feeling of heat and one patient had mild pain during the injection. Even large volumes rapidly injected (up to 20 ml/s of the commercially available solution) were well tolerated. DSA with intra-arterial Gd-DTPA seems to be a suitable alternative for vascular imaging if iodine-containing contrast materials are contraindicated. (orig.) [de

  5. X-ray contrast media-an overview

    International Nuclear Information System (INIS)

    Christiansen, Cathrine

    2005-01-01

    X-ray contrast media are chemically inert drugs which are given intravascularly in very high amounts within a very short time period. Although they are regarded as relatively safe drugs, adverse reactions can occur: these are normally divided into immediate and delayed reactions. The latter appear hours to days after injection. Immediate reactions have been drastically reduced since the introduction of non-ionic monomers and non-ionic dimers. However, the delayed reactions still occur in a frequency of 1-3% in X-ray contrast media exposed patients. The majority of these reactions are mild and manifest as skin eruption, but severe reactions can also occur. Further improvement of the safety of these drugs is only possible with a better understanding of etiologies behind the observed adverse reactions

  6. Diagnostic capabilities of the contrast medium verografin in liposomes (animal experiments)

    International Nuclear Information System (INIS)

    Rozenberg, O.A.; Khason, K.P.; Aliyakparov, M.T.; Davidenkova, E.F.; Zherbin, E.A.; Akademiya Meditsinskikh Nauk SSSR, Leningrad. Inst. Ehksperimental'noj Meditsiny)

    1985-01-01

    Some examples for the diagnosis of various diseases of liver and spleen after intravenous (cats, dogs) or intraportal (rodents) injection of lecithin-cholesterol liposomes containing the water soluble contrast medium verografin are described. Tumors of 1 mm were found in the spleen of mice with lymphogranulomatosis, hepatomas of 3-5 mm in rats and lesions of 10 mm in cats with turpentine abscesses. The application of liposomes containing radiographic contrast media offers good possibilities for the diagnosis of liver and spleen. (author)

  7. Computed tomography of the cervical spine with iv injection of contrast medium

    International Nuclear Information System (INIS)

    Magnaldi, S.; Pozzi-Mucelli, R.S.; Cova, M.A.; De Morpurgo, P.

    1989-01-01

    Computed Tomography (CT) without contrast medium is largely applied to the study of intervertebral disk pathology in the lumbar spine, but has not been widely accepted in cervical spine, due to technical and anatomical limitations. For these reasons many neuroradiologists still prefer myelography or myelo-CT. CT may yield better results if combined with iv contrast medium injection, which allows a better visualization of disk herniation. This technique is aimed at enhancing the density of the venous plexus which is located close to the intervertebral disk the vertebral bodies and the neural foramina. A better contrast enhancement is thus obtained between the disk and the spinal cord. The authors' experience is based on 61 patients who underwent contrast enhanced CT; in 22 cases myelography and myelo-CT were also performed. The authors describe their technique and the most frequent CT findings of disk hernation: the typical finding includes a focal hypodensity surrounded by a linear blush, due to a posteriorly dislocated epidural vein. The posterior linear blush alone may be present in few cases. Contrast enhanced CT is very useful in the study of disk pathology of the cervical spine, even when compared with myelography and myelo-CT, due the increase in the density of epidural plexus it allows. However, the technique must be very accurate if the same results as those of myelo-CT are to be obtained

  8. The association between use of metformin and change in serum CO_2 level after administration of contrast medium

    International Nuclear Information System (INIS)

    Kim, S.K.; Jung, J.; Jung, J.H.; Kim, K.Y.; Baek, J.-H.; Hahm, J.R.

    2016-01-01

    Aim: To evaluate the changes in serum creatinine and total CO_2 levels in patients receiving metformin during administration of contrast medium. Materials and methods: Patient records from January 2012 to December 2012 after the administration of contrast medium were reviewed retrospectively. A total of 924 patients were included for the final analysis. Of them, 105 received metformin during contrast medium administration, 112 were taking other oral hypoglycaemic agents, and 707 patients were not diabetic (controls). Results: No significant change in total CO_2 levels was detected (p=0.678). Metabolic acidosis was present in 33 (31.4%) metformin users, 31 (28.6%) other oral hypoglycaemic agent users, and 153 (21.6%) control patients. In the present logistic regression analysis, age, baseline levels of creatinine, and total CO_2 levels were associated with metabolic acidosis after contrast medium exposure. Conclusion: These data indicate the presence of a coexisting risk factor, other than metformin use, associated with metabolic acidosis after contrast medium exposure. No relationship was found between the use of metformin and metabolic acidosis during contrast medium exposure. - Highlights: • The use of metformin was not associated with metabolic acidosis after contrast exposure. • The coexisting risk factors for metabolic acidosis were present in patient with metabolic acidosis after contrast exposure. • There is a need to consider the maintenance of metformin during a CT scan in patients with a low risk for lactic acidosis.

  9. GE-145, a new low-osmolar dimeric radiographic contrast medium

    International Nuclear Information System (INIS)

    Wistrand, Lars-G.; Rogstad, Astri; Hagelin, Gunnar

    2010-01-01

    Background: Contrast-induced nephrotoxicity is a significant risk when using radiographic contrast media clinically, especially in high risk patients. Consequently, there is a need for a new contrast agent with improved clinical safety with regards to nephrotoxicity. Purpose: To evaluate the physicochemical properties as well as the preclinical safety and biodistribution parameters of the newly developed radiographic contrast medium GE-145. Material and Methods: Standard methods for radiographic contrast media were used for evaluation of physicochemical properties. The acute toxicity in rats was studied at 8, 10, and 12.5 gI/kg, the clinical chemistry parameters were determined, and histology of the kidneys was performed. Biodistribution was studied in rats using 123 I-labeled GE-145. Results: GE-145 is more hydrophilic than iodixanol and has a considerably lower osmolality. The viscosity is similar to that of iodixanol and the protein binding is low. The acute toxicity is similar to that of iodixanol and the biodistribution is similar to that of other radiographic contrast media, showing mainly renal excretion. Kidney histology showed a moderate reversible vacuolization, similar to that of iodixanol. Conclusion: GE-145 exhibits similar preclinical properties to other dimeric radiographic contrast media. In addition, the low osmolality enables an iso-osmolar formulation containing a significantly higher concentration of electrolytes than Visipaque

  10. [Guideline 'Precautionary measures for contrast media containing iodine'

    NARCIS (Netherlands)

    Dijk Azn, R. van; Wetzels, J.F.M.; Dam, M.A. ten; Aarts, N.J.; Schimmelpenninck-Scheiffers, M.L.; Freericks, M.P.; Said, S.A.M.; Geenen, R.W.; Stuurman, A.; Everdingen, J.J. van

    2008-01-01

    Annually, 0.5-1 million injections of contrast media containing iodine are administered in the Netherlands. Almost all contrast media nowadays are low-osmolar and nonionic. Nevertheless, the development ofcontrast-induced nephropathy is still a relevant clinical problem. Through an initiative by the

  11. (Cationic + nonionic) mixed surfactant aggregates for solubilisation of curcumin

    International Nuclear Information System (INIS)

    Kumar, Arun; Kaur, Gurpreet; Kansal, S.K.; Chaudhary, G.R.; Mehta, S.K.

    2016-01-01

    Highlights: • Critical micelle concentration of mixed surfactant has been measured. • Aqueous solubility and alkaline stability of curcumin has been significantly improved. • Location of curcumin within micelles has been evaluated. • Scavenging activity of curcumin has been improved. • Non-intercalative binding with ct-DNA has been observed. - Abstract: Curcumin is a potential drug for variety of diseases. Major limitations of curcumin are low water solubility, rapid hydrolytic degradation in alkaline medium and poor bioavailability. To overcome these limitations, highly potential mixed micellar system has been prepared. In order to reduce inter ionic repulsion and precipitation of surfactants, (cationic + non-ionic) mixed system have been chosen that directly influence its applicability. Hydrophobic chain of non-ionic surfactant significantly influences the cmc of mixed surfactant system as indicated by fluorescence and conductivity data. UV–visible spectroscopy analyses show that solubility, stability and antioxidant property of the curcumin is remarkably improved depending on cmc and aggregation number (N_a_g_g) of mixed surfactants, where N_a_g_g plays crucial role. Generally, curcumin undergoes complete degradation in slight basic medium, but stability has been maintained up to 8 h at pH-13 using formulated mixed micelles (only (20 to 25)% degraded). Location of curcumin which is monitored using emission spectroscopy, fluorescence quenching and "1H NMR spectroscopy techniques play the most important role. Observed results show that the major population of curcumin is located at the polar region and some are in hydrophobic region of the mixed micelles. To ensure the effect of mixed surfactants and curcumin loaded mixed surfactants on DNA, the interaction parameter indicates non-interclative interactions.

  12. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    International Nuclear Information System (INIS)

    Hausegger, K.; Reinprecht, P.; Kau, T.; Igerc, I.; Lind, P.

    2005-01-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk registered , which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk registered can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  13. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hausegger, K.; Reinprecht, P. [Roentgendiagnostisches Zentralinstitut, LKH Klagenfurt (Austria); Kau, T. [Roentgendiagnostisches Zentral Inst., Klagenfurt (Austria); Igerc, I.; Lind, P. [Abt. fuer Nuklearmedizin und Spezielle Endokrinologie, LKH Klagenfurt (Austria)

    2005-06-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk {sup registered}, which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk {sup registered} can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  14. Water as a contrast medium: a re-evaluation using the multidetector-row computed tomography.

    Science.gov (United States)

    Makarawo, Tafadzwa P; Negussie, Edsa; Malde, Sachit; Tilak, Jacqueline; Gayagoy, Jennifer; Watson, Jenna; Francis, Faiz; Lincoln, Denis; Jacobs, Michael J

    2013-07-01

    Water as an intraluminal negative contrast medium produces improved image quality with reduced artefact. However, rapid absorption of oral water in the bowel relative to speed and timing of image capturing has limited its clinical application. These findings predate advances in multidetector-row computed tomography (CT). To re-evaluate differences in image quality, we studied image clarity and luminal distention between the same group of patients who received both a pancreas protocol CT (PPCT) that uses oral water and a conventional positive oral contrast scan. We reviewed 66 patients who had previously undergone both a PPCT and an oral contrast abdominal CT. CT images were independently reviewed by two board-certified radiologists who scored degree of hollow viscus distention and visualization of mural detail using a Likert 5-point scale. Results were evaluated by using the Wilcoxon-signed rank test. Student's t test was applied to evaluate the differences in radiation dosage and Spearman's correlational test was used to evaluate interrater correlation between the radiologists. In comparing the mean radiation dosage, there was no statistical difference between the two protocols, and there was good interrater association with ratios of 0.595 and 0.51 achieved for the PPCT and conventional oral scan, respectively. The Wilcoxon signed-rank test showed statistical differences in the stomach (P contrast medium causing better or equal distention in the bowel and better or equal clarity than routine barium contrast. This calls for a need to reconsider the use of water as a contrast medium in clinical practice.

  15. Nonionic emulsion-mediated synthesis of zeolite beta

    Indian Academy of Sciences (India)

    Zeolite beta synthesis was first carried out in a newly developed emulsion system containing nonionic polyoxyethylated alkylphenol surfactant, which showed interesting non-conventional features. Compared to the conventional hydrothermal synthesis of zeolite beta, the reported nonionic emulsion system showed a faster ...

  16. Analysis on the entrance surface dose and contrast medium dose at computed tomography and angiography in cardiovascular examination

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Hyun [Dept. of Cardiovascular Center, Yeocheon Jeonnam Hospital, Yeosu (Korea, Republic of); Han, Jae Bok; Choi, Nam Gil; Song, Jong Nam [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of)

    2016-12-15

    This study aimed to identify dose reduction measures by retrospectively analyzing the entrance surface dose at computed tomography and angiography in cardiovascular examination and to contribute the patients with renal impairmend and a high probability of side effects to determine the inspection's direction by measuring the contrast usages actually to active actions for the dose by actually measuring the contrast medium dose. The CTDIvol value and air kerma value, which are the entrance surface doses of the two examinations, and the contrast medium dose depending on the number of slides were compared and analyzed. This study was conducted in 21 subjects (11 males; 10 females) who underwent Cardiac Computed Tomographic Angiography (CCTA) and Coronary Angiography (CAG) in this hospital during the period from May 2014 to May 2016. The subject's age was 48-85 years old (mean 65±10 years old), and the weight was 37.6~83.3 kg (mean 63±6 kg). Dose reduction could be expected in the cardiovascular examination using CCTA rather than in the examination using CAG. In terms of contrast medium dose, CAG used a smaller dose than CCTA. In particular, as the number of slides increases at CAG, the contrast medium dose increases. Therefore, in order to reduce the contrast medium dose, the number of slides suitable for the scan range must be selected.

  17. Use of iohexol as a gastrointestinal contrast agent in three dogs, five cats, and one bird

    International Nuclear Information System (INIS)

    Williams, J.; Biller, D.S.; Myer, C.W.; Miyabayashi, T.; Leveille, R.

    1993-01-01

    Barium sulfate suspension is routinely used as contrast medium for upper gastrointestinal procedures. It has been contraindicated for use in cases of suspected perforation. In such instances, water-soluble iodides are recommended for use. Most of the water-soluble iodides available for use in veterinary medicine at this time are hyperosmolar. This results in in transit dilution of the contrast column. The dilution of the contrast agent within the intestines may prevent visualization of a perforation, especially if the perforation is in the distal portion of the small intestine. Iohexol a nonionic water-soluble iodide of low osmolality, is currently used in veterinary medicine for myelography. We have used it as the contrast agent for upper gastrointestinal studies in cases of suspected obstruction or perforation, with good results, and no adverse effects have been associated with its use. Opacity of the contrast column was adequate, and segmentation or flocculation of the column was not apparent

  18. Life-Threatening Thrombocytopenia Following Intravenous Contrast Media Infusion.

    Science.gov (United States)

    Park, Mihwa; Kim, Minjeong; Park, Jisun; Cho, Jinhyun

    2018-01-01

    Radiocontrast media-induced acute severe thrombocytopenia is a very rare complication and potentially life-threatening. Here, we report the case of a 63-year-old male patient with severe acute thrombocytopenia following first exposure to intravenous non-ionic contrast media without immediate allergic reactions. His platelet count dropped from 107000/μL to 2000/μL after six hours of radiocontrast infusion. After administration of corticosteroid and transfusion of platelet concentrates, the platelet count returned gradually to normal within 5 days. To the best of our knowledge, non-ionic contrast media-induced isolated acute severe thrombocytopenia following no signs or symptoms of immediate allergic reaction has never been described. © Copyright: Yonsei University College of Medicine 2018.

  19. Evaluation of changes in vertebral body density following administration of contrast medium during routine CT examination

    International Nuclear Information System (INIS)

    Janicek, M.; Bruna, J.; Stenhova, H.

    1984-01-01

    The possibility is discussed of depicting changes in the density of spongiosis of the vertebral body in normal patients after intravenous administration of a bolus of 40 ml 60% Diazetrizoate in the course of a routine CT examination. The average increase in density immediately after the administration of the contrast medium is 12 H (8%), in the course of 10 minutes is reduced to 5 H (4%) against the initial values in native examination. These average changes are statistically significant, in individual patients, however, the increase in density following the administration of a contrast medium fluctuates considerably (from 0.7% to 10%). Only systematic comparison with various pathological conditions will make it possible to assess the possibilities of the evaluation of the structure of the vertebral body in routine CT with the administration of a contrast medium into the blood flow. (author)

  20. Is the transport of a gadolinium-based contrast agent decreased in a degenerated or aged disc? A post contrast MRI study.

    Directory of Open Access Journals (Sweden)

    Marta Tibiletti

    Full Text Available A post contrast magnetic resonance imaging study has been performed in a wide population of low back pain patients to investigate which radiological and phenotypic characteristics influence the penetration of the contrast agent in lumbar discs in vivo. 37 patients affected by different pathologies (disc herniation, spondylolisthesis, foraminal stenosis, central canal stenosis were enrolled in the study. The selected population included 26 male and 11 female subjects, with a mean age of 42.4 ± 9.3 years (range 18-60. Magnetic resonance images of the lumbar spine were obtained with a 1.5 T scanner (Avanto, Siemens, Erlangen, Germany with a phased-array back coil. A paramagnetic non-ionic contrast agent was injected with a dose of 0.4 ml/kg. T1-weighted magnetic resonance images were subsequently acquired at 5 time points, 5 and 10 minutes, 2, 4 and 6 hours after injection. Endplates presented clear enhancement already 5 minutes after injection, and showed an increase in the next 2 hours followed by a decrease. At 5 and 10 minutes, virtually no contrast medium was present inside the intervertebral disc; afterwards, enhancement significantly increased. Highly degenerated discs showed higher enhancement in comparison with low and medium degenerated discs. Discs classified as Pfirrmann 5 showed a statistically significant higher enhancement than Pfirrmann 1, 2 and 3 at all time points but the first one, possibly due to vascularization. Disc height collapse and Modic changes significantly increased enhancement. Presence of endplate defects did not show any significant influence on post contrast enhancement, but the lack of a clear classification of endplate defects as seen on magnetic resonance scans may be shadowing some effects. In conclusion, disc height, high level of degeneration and presence of Modic changes are factors which increase post contrast enhancement in the intervertebral disc. The effect of age could not be demonstrated.

  1. Health Effects of Non-Ionizing Radiation on Human

    International Nuclear Information System (INIS)

    Zubaidah-Alatas; Yanti Lusiyanti

    2001-01-01

    Increases of development and use of equipment that procedures non-ionizing radiant energy such as laser, radar, microwave ovens, power lines and hand phones, bring about public concern about the possible health effects owing to the non-ionizing radiation exposure. Non ionizing electromagnetic radiation compared to ionizing radiation, has longer wavelength, lower frequency, and lower photon energy in its interaction with body tissues. The term on non-ionizing radiation refers to the groups of electromagnetic radiations with energies less than about 10 eV corresponding to wavelengths in the ultraviolet, visible, infra red microwave and radiofrequency spectral regions. This paper describes the current state of knowledge about types of non-ionizing radiation and the health effects at molecular and cellular levels as well as its effects on human health. (author)

  2. Non-Ionizing Radiation - sources, exposure and health effects

    International Nuclear Information System (INIS)

    Hietanen, M.

    2003-01-01

    Non-ionizing radiation contains the electromagnetic wavelengths from ultraviolet (UV) radiation to static electric and magnetic fields. Optical radiation consists of UV, visible and infrared (IR) radiation while EM fields include static, extremely low (ELF), low frequency (LF) and radiofrequency (RF) fields. The principal scientific organization on non-ionizing radiation is the International Commission on Non-Ionizing Radiation Protection (ICNIRP). The main activity of ICNIRP is to provide guidance on safe exposure and protection of workers and members of the public by issuing statements and recommendations. (orig.)

  3. Iodinated contrast media nephrotoxicity. Nephrotoxicite des produits de contraste iodes

    Energy Technology Data Exchange (ETDEWEB)

    Meyrier, A. (Hopital Avicenne, 93 - Bobigny (France))

    1994-01-01

    In the late seventies, iodinated contrast agents (ICA) were considered to be a major cause of acute iatrogenic renal failure. Over the last decade new contrast agents have been synthesized, nonionic and less hyperosmolar. The incidence of acute renal failure due to ICAs, varies from 3.7 to 70% of cases according to the series, with an average figure of 10.2%. The pathophysiology of ICA nephrotoxicity was mainly studied in laboratory animal models. Three main factors are involved in an inducing ICA-mediated decrease in glomerular filtration rate: reduction of the renal plasma flow, a direct cytotoxic effect on renal tubular cells and erythrocyte alteration leading to intra-renal sludge. Excluding dysglobulinemias with urinary excretion of immunoglobulin light chains, which represent a special case of maximum nephrotoxicity, 4 main risk factors of renal toxicity have been identified in nondiabetic subjects: previous renal failure with serum creatinine levels greater than 140 [mu]mol per liter, extracellular dehydration, age over 60 and use of high doses of ICA and/or repeated ICA injections before serum creatinine levels return to baseline. Preventive measures for avoiding ICA nephrotoxicity are threefold: maintain or restore adequate hydration with saline infusion, stop NSAID treatment several days before ICA administration, and allow a 5 day interval before repeating contrast media injections. New, nonionic and moderately hyperosmolar contrast agents appear to be much less nephrotoxic than conventional ICAs in laboratory animals and in high-risk patients. It is advisable to select such contrast media for investigating high-risk patients. This approach was recently substantiated in well designed, randomized clinical studies which included more than 2 000 patients. (author).

  4. Comparison between the efficacy of dimeric and monomeric non-ionic contrast media (iodixanol vs iopromide) in urography in patients with macroscopic haematuria

    International Nuclear Information System (INIS)

    Stacul, F.; Cova, M.; Pravato, M.; Floriani, I.

    2003-01-01

    Non-ionic dimers induce less diuresis than non-ionic monomers, resulting in increased opacification of the urinary tract in intravenous urography. This trial compared the diagnostic efficacy of iodixanol and iopromide in patients with macroscopic haematuria. One hundred consecutive patients with normal renal function and macroscopic haematuria entered a double blind, comparative, randomised, parallel trial. Contrast media were given with bolus injection in doses of 300 mgI/kg b.w. Radiographs were blindly evaluated by three radiologists who analysed different parameters (calyceal density and filling, papillary blush detection, delineation of collecting ducts, renal pelvis opacification, visualisation of ureters, bladder density, bladder distention) and estimated the diagnostic confidence (whether abnormal findings were definitely absent, probably absent, doubtful, probably present or certainly present). Radiological diagnoses were compared with final diagnoses. Results were summarised as the ratio of the odds of having a worse performance of iopromide vs iodixanol. Iodixanol showed a significantly better calyceal density and filling [odds ratio (OR): 1.96; 95% confidence interval (CI): 1.60-2.41], a significantly better pelvis opacification (OR 2.91; CI 2.02-4.18) and a significantly more frequent papillary blush detection (OR 1.95; CI 1.29-2.95). Iopromide showed a significantly better ureteral visualisation (OR 0.67; CI 0.48-0.92) and a significantly higher bladder distention (OR 0.59; CI 0.36-0.99). Iodixanol allowed a significantly higher diagnostic confidence as to calyceal evaluation (OR 1.35; CI 1.01-1.79). No significant differences were found with regard to other parameters. The results confirmed theoretical expectations. The higher opacification provided by iodixanol allowed better results and a higher diagnostic confidence in the upper excretory pathway. (orig.)

  5. Duplex-assisted carotid artery stenting without administration of contrast medium for patients with chronic kidney disease or allergic reaction.

    Science.gov (United States)

    Mizowaki, Takashi; Fujita, Atsushi; Imahori, Taichiro; Uyama, Atsushi; Inoue, Satoshi; Kohta, Masaaki; Hamaguchi, Hirotoshi; Sasayama, Takashi; Hosoda, Kohkichi; Kohmura, Eiji

    2016-07-01

    We aimed to investigate the safety and feasibility of duplex-assisted carotid artery stenting (CAS) without administration of contrast medium for the prevention of adverse reactions. Fifteen patients (9 % of all CASs) with severe carotid stenosis (≥70 %) associated with chronic kidney disease (CKD) (stage ≥3) or allergy to contrast medium underwent duplex-assisted CAS without administration of contrast medium over 4 years. The procedural success rate and perioperative complication rates were compared between the duplex-assisted CAS (n = 15) and conventional CAS (n = 153) groups. The technical success rate was 100 % in both groups. Combined stroke or death rates during the post-procedural period did not differ significantly between the duplex-assisted CAS group (0/15, 0 %) and conventional CAS group (4/153, 2.6 %). None of the 14 patients with CKD in the duplex-assisted CAS group experienced further deterioration of renal function. The mean surface radiation dose of participants in the duplex-assisted CAS group (n = 13, 312 ± 131 mGy) was significantly lower than that of the conventional CAS group (n = 31, 1036 ± 571 mGy) (p duplex-assisted CAS group (156 ± 39.7 min) and the conventional CAS group (156 ± 37.4 min). Duplex-assisted CAS without administration of contrast medium could be an alternative option in selected patients deemed to be at high risk for renal failure from nephrotoxic contrast medium or who have an allergy to contrast medium.

  6. Digital subtraction angiography and intraarterial contrast medium injection for coronary examinations

    Energy Technology Data Exchange (ETDEWEB)

    Tobio, R; Kallmeyer, C; Castello, J

    1985-01-01

    Digital subtraction angiography (DSA) is an established method of vasography, most extensively used as i.v. DSA. Intraarterial injection, however, applying selective or non-selective contrast medium injection, seems to be at least as important a technique although it has not yet met with corresponding interest. The article explains advantages of the technique for angiographic examinations, in particular of coronary angiography.

  7. Evaluation of contrast media submitted to ionizing radiation

    International Nuclear Information System (INIS)

    Pinho, Katia Elisa Prus; Gewehr, Pedro Miguel; Soboll, Danyel Scheidegger; Silva, Caroline Werner Pereira da; Barison, Andersson; Tilly Junior, Joao Gilberto

    2009-01-01

    Objective: the purpose of the present study was to investigate the influence of ionizing radiation from x-rays and gamma rays on the molecular structure stability of several radiologic contrast media employed in diagnostic imaging by means of 1 H and 1 3C nuclear magnetic resonance spectroscopy. Materials and methods: eight different types of iodinated contrast media (three ionic and five non-ionic) were exposed to x-rays and gamma rays irradiation. Subsequently, the 1 H and 1 3C{ 1 H} nuclear magnetic resonance spectra of these contrast media were collected. Results: the 1 H and 1 3C{ 1 H} nuclear magnetic resonance spectra of both ionic and non-ionic contrast media irradiated by x-rays or gamma rays demonstrated the absence of any alteration of the contrast media chemical composition. Conclusion: there is no problem in keeping contrast media inside examination rooms or close to radiological equipment. It is important to mention that, during the tests, the samples were directly irradiated, while in a radiology examination room, the irradiation is not direct and, therefore, radiation levels in these cases are much lower than those employed in the present study. (author)

  8. Influence of radiographic contrast agents on quantitative coronary angiography

    International Nuclear Information System (INIS)

    Jost, Stefan; Hausmann, Dirk; Lippolt, Peter; Gerhardt, Uwe; Lichtlen, Paul R.

    1997-01-01

    Purpose. Quantitative angiographic studies on the vasomotility of epicardial coronary arteries are gaining increasing relevance. We investigated whether radiographic contrast agents might influence coronary vasomotor tone and thereby the results of such studies. Methods. Coronary angiograms were taken in 12 patients with coronary artery disease at intervals of 5, 3, 2, and 1 min with the low-osmolar, nonionic contrast agent iopamidol 300, and were repeated at identical intervals with the high-osmolar, ionic agent diatrizoate 76%. Results. Quantitative cine film analysis demonstrated no significant diameter changes in angiographically normal and stenotic coronary arteries with iopamidol. With diatrizoate, however, normal segments were dilated 2%±2% (p<0.01) after 2 min and 10%±3% after the 1 min interval (p<0.001). Stenoses showed no uniform responses to diatrizoate. Conclusion. Low-osmolar, nonionic contrast agents should be preferred for quantitative angiographic studies on epicardial coronary vasomotility. When using ionic contrast agents, injection intervals of at least 3 min are required

  9. Signal effects of various radiographic contrast media and their interaction with gadolinium DTPA during MRT

    International Nuclear Information System (INIS)

    Kopka, L.; Funke, M.; Fischer, U.; Vosshenrich, R.; Schroeder, M.; Grabbe, E.

    1994-01-01

    T 1 and T 2 weighted signals dereived from various radiological contrast media were studied during MRT spin-echo sequences. In addition, the interaction between radiological contrast media and Gadolinium-DTPA concerning T 1 signals was evaluated. Ionic (ioxitalaminic acid) and non-ionic radiological contrast media (Iopromid, Iotrolan) were used in diagnostic concentrations. Measurements were carried out with a superconductive magnet of 1.5 Tesla. Radiological contrast media produced significantly higher signals than a physiological sodium chloride solution in T 1 -weighted spin-echo sequences. Evn small amounts (15% of total volume) of radiological contrast media during T 1 -weighted spin-echo sequences led to a significant reduction (about 25%) of the signal intensity of a 2 mM Gadolinium-DTPA solution. This may lead to diagnostic problems, as was shown in a series of 25 MR arthrograms of the shoulder. It is recommended than an interval of at least 6 hours should elapse between the use of a radiological contrst medium and an MRT examination. (orig.) [de

  10. Automated contrast medium monitoring system for computed tomography--Intra-institutional audit.

    Science.gov (United States)

    Lauretti, Dario Luca; Neri, Emanuele; Faggioni, Lorenzo; Paolicchi, Fabio; Caramella, Davide; Bartolozzi, Carlo

    2015-12-01

    The aim of this study was to analyze the usage and the data recorded by a RIS-PACS-connected contrast medium (CM) monitoring system (Certegra(®), Bayer Healthcare, Leverkusen, Germany) over 19 months of CT activity. The system used was connected to two dual syringe power injectors (each associated with a 16-row and a high definition 64-row multidetector CT scanner, respectively), allowing to manage contrast medium injection parameters and to send and retrieve CT study-related information via RIS/PACS for any scheduled contrast-enhanced CT examination. The system can handle up to 64 variables and can be accessed via touchscreen by CT operators as well as via a web interface by registered users with three different hierarchy levels. Data related to CM injection parameters (i.e. iodine concentration, volume and flow rate of CM, iodine delivery rate and iodine dose, CM injection pressure, and volume and flow rate of saline), patient weight and height, and type of CT study over a testing period spanning from 1 June 2013 to 10 January 2015 were retrieved from the system. Technical alerts occurred for each injection event (such as system disarm due to technical failure, disarm due to operator's stop, incomplete filling of patient data fields, or excessively high injection pressure), as well as interoperability issues related to data sending and receiving to/from the RIS/PACS were also recorded. During the testing period, the CM monitoring system generated a total of 8609 reports, of which 7629 relative to successful injection events (88.6%). 331 alerts were generated, of which 40 resulted in injection interruption and 291 in CM flow rate limitation due to excessively high injection pressure (>325 psi). Average CM volume and flow rate were 93.73 ± 17.58 mL and 3.53 ± 0.89 mL/s, and contrast injection pressure ranged between 5 and 167 psi. A statistically significant correlation was found between iodine concentration and peak IDR (rs=0.2744, psystems can provide a full

  11. Enhancement effects of test injection with a small amount of MR contrast medium in the oral and maxillofacial region

    International Nuclear Information System (INIS)

    Yanagi, Yoshinobu; Asaumi, Jun-ichi; Konouchi, Hironobu; Hisatomi, Miki; Matsuzaki, Hidenobu; Murakami, Jun; Maki, Yuu; Unetsubo, Teruhisa; Kishi, Kanji

    2006-01-01

    Purpose: To examine whether the signal intensity of dynamic contrast-enhanced MRI (DCE-MRI) is altered by test injection of 1 ml of contrast medium, and if so, whether this change affects the DCE-MRI analysis. Materials and methods: Six healthy volunteers were examined by DCE-MRI using a Magnevist syringe and/or an Omniscan syringe for the injection of contrast medium. Each scan was performed 10 times using steady-state free precession (3D-FISP), a sequence for DCE-MRI, before and after intravenous injection of 1 ml of the contrast medium. The internal pterygoid muscle, masseter muscle, tongue, parotid gland, submandibular gland, bone marrow of the mandible, subcutaneous adipose tissue, and common carotid artery were determined to be regions of interest (ROI), and the ROI internal average signal intensity was measured. The 10 data sets obtained before or after contrast medium administration for each ROI were evaluated using the paired t-test. Results: The test injection increased the signal intensities of six of eight ROIs, with all 20 experiments in the submandibular gland showing significant differences. There was no significant difference in the two ROIs corresponding to the carotid artery and subcutaneous adipose tissue of the cheek. Conclusions: The enhanced signal intensity in the tissue might have been caused by the small amount of contrast medium in the test injection. To eliminate this discrepancy caused by the test injection, a pre-contrast scan should be performed when the average signal intensity of an ROI is measured. We therefore believe that the data obtained before a test injection may be important in the analysis of DCE-MRI

  12. Lecithine as an adjuvant in resorption of contrast medium in oral cholecystography

    International Nuclear Information System (INIS)

    Lindgren, I.

    1978-01-01

    No or poor filling of the gallbladder was obtained in 21 patients at cholecystography. They were re-examined after 10 days or later with the addition of lecithine to the contrast medium. The filling of the gallbladder, which was without abnormality, was improved in all cases. The mechanism of this effect is discussed. (Auth.)

  13. Studies of bio-mimetic medium of ionic and non-ionic micelles by a simple charge transfer fluorescence probe N,N-dimethylaminonapthyl-(acrylo)-nitrile

    Science.gov (United States)

    Samanta, Anuva; Paul, Bijan Kumar; Guchhait, N.

    2011-05-01

    In this report we have studied micellization process of anionic, cationic and non-ionic surfactants using N,N-dimethylaminonapthyl-(acrylo)-nitrile (DMANAN) as an external fluorescence probe. Micropolarity, microviscosity, critical micellar concentration of these micelles based on steady state absorption and fluorescence and time resolved emission spectroscopy of the probe DMANAN show that the molecule resides in the micelle-water interface for ionic micelles and in the core for the non-ionic micelle. The effect of variation of pH of the micellar solution as well as fluorescence quenching measurements of DMANAN provide further support for the location of the probe in the micelles.

  14. A severe, late reaction to radiological contrast media mimicking a sepsis syndrome

    International Nuclear Information System (INIS)

    Burton, P.R.; Jarmolowski, E.; Raineri, F.; Buist, M.D.; Wriedt, H.R.

    1999-01-01

    An unusual, severe delayed reaction to non-ionic intravenous contrast media was observed. A 44-year-old man underwent a computed tomography scan with non-ionic contrast media. Four hours later the patient collapsed with hypotension and cardiovascular shock. Aggressive management (including inotropic support and fluid resuscitation) was instituted in the intensive care unit. Rigorous imaging and biochemical and microbiological investigation failed to identify a source of this man's circulatory collapse. A rapid recovery ensued and at 3 months follow-up the patient was suffering no residual effects from this event. To our knowledge, this is only the second report of a severe delayed reaction to radiological contrast media and the first that manifested as a prolonged hypotensive syndrome. Despite the introduction of non-ionic low osmolar radiological contrast media (NIM), the incidence of adverse reactions to these agents remains at between 3 and 12%. Most of these reactions are acute, self-limiting events (nausea, vomiting, urticaria, diarrhoea) and no treatment is required. The mortality rate of these adverse reactions has been quoted at 0.0020.009% of all procedures. Most of these severe reactions are acute anaphylactoid events manifested by hypotension and bronchospasm. Delayed adverse reactions to NIM have been reported to occur with a frequency of between 8.0 and 27.1%. These reactions are almost uniformly self-limiting and non-life threatening, requiring minimal intervention. We report an unusual late adverse reaction to NIM, which presented with many of the features of a severe sepsis syndrome. Non-ionic low osmolar radiological contrast media has the capacity to cause severe delayed reactions in rare instances, but the pathophysiological mechanisms of these reactions are poorly understood and, therefore, diagnosis and management of this clinical situation presented many difficulties. Copyright (1999) Blackwell Science Pty Ltd

  15. Prevention of generalized reactions to contrast media: a consensus report and guidelines

    International Nuclear Information System (INIS)

    Morcos, S.K.; Thomsen, H.S.; Webb, J.A.W.

    2001-01-01

    The aim of this study was to document, using consensus methodology, current practice for prevention of generalized reactions to contrast media, to identify areas where there is disagreement or confusion and to draw up guidelines for reducing the risk of generalized contrast media reactions based on the survey and a review of the literature. A document with 165 questions was mailed to 202 members of the European Society of Urogenital Radiology. The questions covered risk factors and prophylactic measures for generalized contrast media reactions. Sixty-eight members (34%) responded. The majority indicated that a history of moderate and severe reaction(s) to contrast media and asthma are important risk factors. The survey also indicated that patients with risk factors should receive non-ionic contrast media. In patients at high risk of reaction, if the examination is deemed absolutely necessary, a resuscitation team should be available at the time of the procedure. The majority (91%) used corticosteroid prophylaxis given at least 11 h before contrast medium to patients at increased risk of reaction. The frequency of the dosage varied from one to three times. Fifty-five percent also use antihistamine Hl, mainly administered orally and once. Antihistamine H2 and ephedrine are rarely used. All essential drugs are available on the emergency resuscitation trolley. Patients with risk factors are observed up to 30 min by 48% and up to 60 min by 43% of the responders. Prophylactic measures are not taken before extravascular use of contrast media. Prophylactic drugs are given to patients with a history of moderate or severe generalized reaction to contrast media. In patients with asthma, opinion is divided with only half of the responders giving prophylactic drugs. Aspirin, β-blockers, interleukin-2 and non-steroid anti-inflammatory drugs are not considered risk factors and therefore are not stopped before injection of contrast media. The survey showed some variability in

  16. Prevention of generalized reactions to contrast media: a consensus report and guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Morcos, S.K. [Dept. of Diagnostic Imaging, Northern General Hospital, Sheffield (United Kingdom); Thomsen, H.S. [Dept. of Diagnostic Radiology, Herlev Hospital, University of Copenhagen (Denmark); Webb, J.A.W. [Diagnostic Radiology Department, St. Bartholomew' s Hospital, London (United Kingdom)

    2001-09-01

    The aim of this study was to document, using consensus methodology, current practice for prevention of generalized reactions to contrast media, to identify areas where there is disagreement or confusion and to draw up guidelines for reducing the risk of generalized contrast media reactions based on the survey and a review of the literature. A document with 165 questions was mailed to 202 members of the European Society of Urogenital Radiology. The questions covered risk factors and prophylactic measures for generalized contrast media reactions. Sixty-eight members (34%) responded. The majority indicated that a history of moderate and severe reaction(s) to contrast media and asthma are important risk factors. The survey also indicated that patients with risk factors should receive non-ionic contrast media. In patients at high risk of reaction, if the examination is deemed absolutely necessary, a resuscitation team should be available at the time of the procedure. The majority (91%) used corticosteroid prophylaxis given at least 11 h before contrast medium to patients at increased risk of reaction. The frequency of the dosage varied from one to three times. Fifty-five percent also use antihistamine Hl, mainly administered orally and once. Antihistamine H2 and ephedrine are rarely used. All essential drugs are available on the emergency resuscitation trolley. Patients with risk factors are observed up to 30 min by 48% and up to 60 min by 43% of the responders. Prophylactic measures are not taken before extravascular use of contrast media. Prophylactic drugs are given to patients with a history of moderate or severe generalized reaction to contrast media. In patients with asthma, opinion is divided with only half of the responders giving prophylactic drugs. Aspirin, {beta}-blockers, interleukin-2 and non-steroid anti-inflammatory drugs are not considered risk factors and therefore are not stopped before injection of contrast media. The survey showed some variability in

  17. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT--a pooled analysis of two randomized trials

    DEFF Research Database (Denmark)

    Thomsen, Henrik S; Morcos, Sameh K

    2009-01-01

    of the LOCM were also observed in patients with GFR contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM......The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients...... with glomerular filtration rate (GFR) contrast-enhanced MDCT examinations and to compare the rates of CIN following the IV administration of low-osmolar contrast media (LOCM, iopamidol and iomeprol) and an iso-osmolar contrast medium (IOCM, iodixanol). A total of 301 adult patients...

  18. Effect of barium sulfate contrast medium on rheology and sensory texture attributes in a model food.

    Science.gov (United States)

    Ekberg, O; Bulow, M; Ekman, S; Hall, G; Stading, M; Wendin, K

    2009-03-01

    The swallowing process can be visualized using videoradiography, by mixing food with contrast medium, e.g., barium sulfate (BaSO(4)), making it radiopaque. The sensory properties of foods may be affected by adding this medium. To evaluate if and to what extent sensory and rheological characteristics of mango purée were altered by adding barium sulfate to the food. This study evaluated four food samples based on mango purée, with no or added barium sulfate contrast medium (0%, 12.5%, 25.0%, and 37.5%), by a radiographic method, and measured sensory texture properties and rheological characteristics. The sensory evaluation was performed by an external trained panel using quantitative descriptive analysis. The ease of swallowing the foods was also evaluated. The sensory texture properties of mango purée were significantly affected by the added barium in all evaluated attributes, as was the perception of particles. Moreover, ease of swallowing was significantly higher in the sample without added contrast medium. All samples decreased in extensional viscosity with increasing extension rate, i.e., all samples were tension thinning. Shear viscosity was not as dependent on the concentration of BaSO(4) as extensional viscosity. Addition of barium sulfate to a model food of mango purée has a major impact on perceived sensory texture attributes as well as on rheological parameters.

  19. Magnetic resonance tomography for focal lesions in the liver using the para-magnetic contrast medium gadolinium DTPA

    International Nuclear Information System (INIS)

    Hamm, B.; Roemer, T.; Felix, R.; Wolf, K.J.; Klinikum Charlottenburg, Berlin

    1986-01-01

    The use of the para-magnetic contrast medium gadolinium DTPA for magnetic resonance tomography of focal lesions in the liver was investigated in 31 patients. Two dosage schedules of the contrast medium (0.1 and 0.2 mmol/kg body weight) were used with field strengths of 0.35 and 0.5 Tesla. Using T 1 sequences, gadolinium DTPA showed increased signal intensity in the liver and in tumours, but this was significantly more marked in the tumour. On T 1 spin-echo sequences, previously iso-intense lesions became visible after administration of contrast. On the other hand, contrast-enhanced lesions were less well seen on inversion recovery sequences because of a reduction in the contrast between tumour and liver tissue. The contrast between tumour and liver tissue was not improved by gadolinium DTPA in comparison with precontrast inversion recovery sequences and T 2 spin-echo sequences. The perfusion of intra-hepatic tumours could be elucidated by magnetic resonance tomography after the administration of gadolinium DTPA. (orig.) [de

  20. Iodinated contrast media nephrotoxicity

    International Nuclear Information System (INIS)

    Meyrier, A.

    1994-01-01

    In the late seventies, iodinated contrast agents (ICA) were considered to be a major cause of acute iatrogenic renal failure. Over the last decade new contrast agents have been synthesized, nonionic and less hyperosmolar. The incidence of acute renal failure due to ICAs, varies from 3.7 to 70% of cases according to the series, with an average figure of 10.2%. The pathophysiology of ICA nephrotoxicity was mainly studied in laboratory animal models. Three main factors are involved in an inducing ICA-mediated decrease in glomerular filtration rate: reduction of the renal plasma flow, a direct cytotoxic effect on renal tubular cells and erythrocyte alteration leading to intra-renal sludge. Excluding dysglobulinemias with urinary excretion of immunoglobulin light chains, which represent a special case of maximum nephrotoxicity, 4 main risk factors of renal toxicity have been identified in nondiabetic subjects: previous renal failure with serum creatinine levels greater than 140 μmol per liter, extracellular dehydration, age over 60 and use of high doses of ICA and/or repeated ICA injections before serum creatinine levels return to baseline. Preventive measures for avoiding ICA nephrotoxicity are threefold: maintain or restore adequate hydration with saline infusion, stop NSAID treatment several days before ICA administration, and allow a 5 day interval before repeating contrast media injections. New, nonionic and moderately hyperosmolar contrast agents appear to be much less nephrotoxic than conventional ICAs in laboratory animals and in high-risk patients. It is advisable to select such contrast media for investigating high-risk patients. This approach was recently substantiated in well designed, randomized clinical studies which included more than 2 000 patients. (author)

  1. Clinical observation of adverse drug reactions to non-ionic iodinated contrast media in population with underlying diseases and risk factors

    Science.gov (United States)

    Li, Xue; Liu, Heng; Zhao, Li; Liu, Junling; Cai, Li; Liu, Lei

    2017-01-01

    Objective: To determine the adverse drug reaction (ADR) profile of non-ionic iodinated contrast media in populations with underlying diseases and risk factors and to provide guidance for more safe and rational use of iodinated contrast media (ICMs) in the clinic. Methods: Data from 120,822 cases who underwent enhanced CT examination in our hospital from January 2014 to March 2016 were collected. A standardized case report form was used for data collection and analysis. Results: The incidence of ADRs was 0.4% and 0.44% in patients with and without underlying diseases, respectively (p = 0.378). Risk factor analysis revealed that patients with asthma had the highest incidence of ADRs, followed by patients with cardiac insufficiency and patients who were aged had the lowest incidence. There was a low incidence of ADRs in patients under metformin (0.36%) and β-adrenaline receptor antagonist (0.20%) medication. The incidence was the highest in patients with previous ADRs to ICMs (7.17%) and the lowest in those with a history of ICM usage but no previous reactions (0.32%). ADRs were more common in patients at high risk at a higher injection dose (≥100 ml; p < 0.01) and speed (≥5 ml s−1; p < 0.01). Conclusion: The incidence of ADRs was extremely low in patients regardless of underlying diseases. Some high-risk factors have certain correlations with the occurrence of ADRs. Particular attention should be given to patients at high risk when performing enhanced CT examination. Advances in knowledge: The correlation between various risk factors and underlying diseases and ADRs was comprehensively analyzed in a large-scale population. PMID:27928926

  2. The predictive value of the product of contrast medium volume and urinary albumin/creatinine ratio in contrast-induced acute kidney injury.

    Science.gov (United States)

    Wang, Chunrui; Ma, Shuai; Deng, Bo; Lu, Jianxin; Shen, Wei; Jin, Bo; Shi, Haiming; Ding, Feng

    2017-11-01

    Preexisting renal impairment and the amount of contrast media are the most important risk factors for contrast-induced acute kidney injury (CI-AKI). We aimed to investigate whether the product of contrast medium volume and urinary albumin/creatinine ratio (CMV × UACR) would be a better predictor of CI-AKI in patients undergoing nonemergency coronary interventions. This was a prospective single-center observational study, and 912 consecutive patients who were exposed to contrast media during coronary interventions were investigated prospectively. CI-AKI is defined as a 44.2 μmol/L rise in serum creatinine or a 25% increase, assessed within 48 h after administration of contrast media in the absence of other causes. Fifty patients (5.48%) developed CI-AKI. The urinary albumin/creatinine ratio (UACR) (OR = 1.002, 95% CI = 1.000-1.003, p = .012) and contrast medium volume (CMV) (OR = 1.008, 95% CI = 1.001-1.014, p = .017) were independent risk factors for the development of CI-AKI. The area under the ROC curve of CMV, UACR and CMV × UACR were 0.662 (95% CI = 0.584-0.741, p < .001), 0.761 (95% CI = 0.674-0.847, p < .001) and 0.808 (95% CI = 0.747-0.896, p < .001), respectively. The cutoff value of CMV × UACR to predict CI-AKI was 1186.2, with 80.0% sensitivity and 62.2% specificity. The product of CMV and UACR (CMV × UACR) might be a predictor of CI-AKI in patients undergoing nonemergency coronary interventions, which was superior to CMV or UACR alone.

  3. Protection criteria from the non-ionizing radiations

    International Nuclear Information System (INIS)

    Touzet, Rodolfo E.

    2004-01-01

    The first objective of the protection philosophy is to determinate the relation reason-effect in order to establish the exposition thresholds to acceptable values. To establish the radioprotection criteria is important to considerate the following: a-) The damage and effects of the non-ionizing radiation; b-) The physical aspects of the fields exposition; and c-) The dosimetry of the involucrate tissues. The non-ionizing radiation includes the optics radiations (ultraviolet, visible, infrared and laser), and the electromagnetic radiations (microwave, radars, magnetic and electrostatics fields)

  4. Comparison between two positive and one negative oral contrast medium for abdominal CT diagnosis

    International Nuclear Information System (INIS)

    Zwaan, M.; Gmelin, E.

    1989-01-01

    In a prospective randomised study three groups of 30 patients each were subjected to CT of the entire abdomen. The oral intestinal contrast media used were iodine solution (2%), barium suspension (1.5%) and paraffin emulsion (25%). The results were evaluated according to imaging, artifacts, assessability of the intestinal wall, taste and side effects. All three contrast media are suitable for marking the gastrointestinal tract; paraffin shows advantages in the upper part of the tract and is the only medium that enables assessment of the wall, while causing the lowest rate of artifacts. Barium has a high acceptance and the best tolerance of all contrast agents. (orig.) [de

  5. Microwave-assisted nonionic surfactant extraction of aliphatic hydrocarbons from petroleum source rock

    Energy Technology Data Exchange (ETDEWEB)

    Akinlua, A., E-mail: geochemresearch@yahoo.com [Fossil Fuels and Environmental Geochemistry Group, Department of Chemistry, Obafemi Awolowo University, Ile-Ife (Nigeria); Jochmann, M.A.; Laaks, J.; Ewert, A.; Schmidt, T.C. [Instrumental Analytical Chemistry, University Duisburg-Essen, Universitaetsstr, 5, 45141 Essen (Germany)

    2011-04-08

    The extraction of aliphatic hydrocarbons from petroleum source rock using nonionic surfactants with the assistance of microwave was investigated and the conditions for maximum yield were determined. The results showed that the extraction temperatures and kinetic rates have significant effects on extraction yields of aliphatic hydrocarbons. The optimum temperature for microwave-assisted nonionic surfactant extraction of aliphatic hydrocarbons from petroleum source rock was 105 deg. C. The optimum extraction time for the aliphatic hydrocarbons was at 50 min. Concentration of the nonionic surfactant solution and irradiation power had significant effect on the yields of aliphatic hydrocarbons. The yields of the analytes were much higher using microwave assisted nonionic surfactant extraction than with Soxhlet extraction. The recoveries of the n-alkanes and acyclic isoprenoid hydrocarbons for GC-MS analysis from the extractant nonionic surfactant solution by in-tube extraction (ITEX 2) with a TENAX TA adsorbent were found to be efficient. The results show that microwave-assisted nonionic surfactant extraction (MANSE) is a good and efficient green analytical preparatory technique for geochemical evaluation of petroleum source rock.

  6. Microwave-assisted nonionic surfactant extraction of aliphatic hydrocarbons from petroleum source rock

    International Nuclear Information System (INIS)

    Akinlua, A.; Jochmann, M.A.; Laaks, J.; Ewert, A.; Schmidt, T.C.

    2011-01-01

    The extraction of aliphatic hydrocarbons from petroleum source rock using nonionic surfactants with the assistance of microwave was investigated and the conditions for maximum yield were determined. The results showed that the extraction temperatures and kinetic rates have significant effects on extraction yields of aliphatic hydrocarbons. The optimum temperature for microwave-assisted nonionic surfactant extraction of aliphatic hydrocarbons from petroleum source rock was 105 deg. C. The optimum extraction time for the aliphatic hydrocarbons was at 50 min. Concentration of the nonionic surfactant solution and irradiation power had significant effect on the yields of aliphatic hydrocarbons. The yields of the analytes were much higher using microwave assisted nonionic surfactant extraction than with Soxhlet extraction. The recoveries of the n-alkanes and acyclic isoprenoid hydrocarbons for GC-MS analysis from the extractant nonionic surfactant solution by in-tube extraction (ITEX 2) with a TENAX TA adsorbent were found to be efficient. The results show that microwave-assisted nonionic surfactant extraction (MANSE) is a good and efficient green analytical preparatory technique for geochemical evaluation of petroleum source rock.

  7. Kinetics of intravenous radiographic contrast medium injections as used on CT: simulation with time delay differential equations in a basic human cardiovascular multicompartment model.

    Science.gov (United States)

    Violon, D

    2012-12-01

    To develop a multicompartment model of only essential human body components that predicts the contrast medium concentration vs time curve in a chosen compartment after an intravenous injection. Also to show that the model can be used to time adequately contrast-enhanced CT series. A system of linked time delay instead of ordinary differential equations described the model and was solved with a Matlab program (Matlab v. 6.5; The Mathworks, Inc., Natick, MA). All the injection and physiological parameters were modified to cope with normal or pathological situations. In vivo time-concentration curves from the literature were recalculated to validate the model. The recalculated contrast medium time-concentration curves and parameters are given. The results of the statistical analysis of the study findings are expressed as the median prediction error and the median absolute prediction error values for both the time delay and ordinary differential equation systems; these are situated well below the generally accepted maximum 20% limit. The presented program correctly predicts the time-concentration curve of an intravenous contrast medium injection and, consequently, allows an individually tailored approach of CT examinations with optimised use of the injected contrast medium volume, as long as time delay instead of ordinary differential equations are used. The presented program offers good preliminary knowledge of the time-contrast medium concentration curve after any intravenous injection, allowing adequate timing of a CT examination, required by the short scan time of present-day scanners. The injected volume of contrast medium can be tailored to the individual patient with no more contrast medium than is strictly needed.

  8. The use of new contrast media agents in radiology

    International Nuclear Information System (INIS)

    Zerbe, M.

    1992-01-01

    The purpose of the document is to present the importance of different categories of contrast media in radiography. Ionic and non-ionic contrast media are presented. Pharmacology and pathophysiology of Iodine contrast media with their effects on special organs of the body like the heart, vessels, lungs and nervous systems are explained. Paramagnetic contrast media used in NMR imaging are presented too. Emphasis is made on contrast media based on Gadolinium like Gd-DTPA, Gd-CL3, Gd-EDTA. Actions of Gd-DTPA applied to images in urography are pointed out

  9. Contrast induced nephropathy

    DEFF Research Database (Denmark)

    Stacul, Fulvio; van der Molen, Aart J; Reimer, Peter

    2011-01-01

    PURPOSE: The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 1999 guidelines on contrast medium-induced nephropathy (CIN). AREAS COVERED: Topics reviewed include the definition of CIN, the choice of contrast medium, the prophylactic me....../min/1.73 m (2) is CIN risk threshold for intravenous contrast medium. • Hydration with either saline or sodium bicarbonate reduces CIN incidence. • Patients with eGFR = 60 ml/min/1.73 m (2) receiving contrast medium can continue metformin normally....

  10. MO-E-17A-02: Incorporation of Contrast Medium Dynamics in Anthropomorphic Phantoms: The Advent of 5D XCAT Models

    Energy Technology Data Exchange (ETDEWEB)

    Sahbaee, P [NC State University, Raleigh, NC (United States); Samei, E [Duke University Medical Center, Durham, NC (United States); Segars, W [Duke University, Durham, NC (United States)

    2014-06-15

    Purpose: To develop a unique method to incorporate the dynamics of contrast-medium propagation into the anthropomorphic phantom, to generate a five-dimensional (5D) patient model for multimodality imaging studies. Methods: A compartmental model of blood circulation network within the body was embodied into an extended cardiac-torso (4D-XCAT) patient model. To do so, a computational physiologic model of the human cardiovascular system was developed which includes a series of compartments representing heart, vessels, and organs. Patient-specific cardiac output and blood volume were used as inputs influenced by the weight, height, age, and gender of the patient's model. For a given injection protocol and given XCAT model, the contrast-medium transmission within the body was described by a series of mass balance differential equations, the solutions to which provided the contrast enhancement-time curves for each organ; thereby defining the tissue materials including the contrastmedium within the XCAT model. A library of time-dependent organ materials was then defined. Each organ in each voxelized 4D-XCAT phantom was assigned to a corresponding time-varying material to create the 5D-XCAT phantom in which the fifth dimension is blood/contrast-medium within the temporal domain. Results: The model effectively predicts the time-varying concentration behavior of various contrast-medium administration in each organ for different patient models as function of patient size (weight/height) and different injection protocol factors (injection rate and pattern, iodine concentration or volume). The contrast enhanced XCAT patient models was developed based on the concentration of iodine as a function of time after injection. Conclusion: Majority of medical imaging systems take advantage of contrast-medium administration in terms of better image quality, the effect of which was ignored in previous optimization studies. The study enables a comprehensive optimization of contrast

  11. Communication: Salt-induced water orientation at a surface of non-ionic surfactant in relation to a mechanism of Hofmeister effect

    Energy Technology Data Exchange (ETDEWEB)

    Hishida, Mafumi; Kaneko, Yohei; Okuno, Masanari; Yamamura, Yasuhisa; Ishibashi, Taka-aki; Saito, Kazuya, E-mail: kazuya@chem.tsukuba.ac.jp [Department of Chemistry, Faculty of Pure and Applied Sciences, University of Tsukuba, Tsukuba, Ibaraki 305-8571 (Japan)

    2015-05-07

    The behavior of water molecules at the surface of nonionic surfactant (monomyristolein) and effects of monovalent ions on the behavior are investigated using the heterodyne-detected vibrational sum frequency generation spectroscopy. It is found that water molecules at the surface are oriented with their hydrogen atoms pointing to the bulk, and that the degree of orientation depends on the anion strongly but weakly on the cation. With measured surface potentials in those saline solutions, it is concluded that the heterogeneous distribution of anions and cations in combination with the nonionic surfactant causes the water orientation. This heterogeneous distribution well explains the contrasting order of anions and cations with respect to the ion size in the Hofmeister series.

  12. Communication: Salt-induced water orientation at a surface of non-ionic surfactant in relation to a mechanism of Hofmeister effect

    International Nuclear Information System (INIS)

    Hishida, Mafumi; Kaneko, Yohei; Okuno, Masanari; Yamamura, Yasuhisa; Ishibashi, Taka-aki; Saito, Kazuya

    2015-01-01

    The behavior of water molecules at the surface of nonionic surfactant (monomyristolein) and effects of monovalent ions on the behavior are investigated using the heterodyne-detected vibrational sum frequency generation spectroscopy. It is found that water molecules at the surface are oriented with their hydrogen atoms pointing to the bulk, and that the degree of orientation depends on the anion strongly but weakly on the cation. With measured surface potentials in those saline solutions, it is concluded that the heterogeneous distribution of anions and cations in combination with the nonionic surfactant causes the water orientation. This heterogeneous distribution well explains the contrasting order of anions and cations with respect to the ion size in the Hofmeister series

  13. Comparison of excretory urographic contrast effects of dimeric and monomeric non-ionic iodinated contrast media in dogs

    International Nuclear Information System (INIS)

    Kishimoto, M.; Yamada, K.; Watanabe, A.; Miyamoto, K.; Iwasaki, T.; Miyake, Y.

    2007-01-01

    In excretory urography, the osmolarity of contrast media has rarely been treated as important in veterinary medicine. In this study, the contrast effect of two contrast media (monomeric iohexol and dimeric iodixanol) in the renal cortex and aorta were compared using computed tomography (CT). Five beagle dogs were used and the study employed a cross-over method for each contrast media. The results showed that there was no difference between the media in the aorta, but iodixanol showed higher CT value and a longer contrast effect than iohexol in the renal cortex, in spite of having the same iodine dosage. It is believed that iodixanol, with its low osmolarity, is diluted less by osmotic diuresis than monomeric iohexol. It is important to consider the osmolarity of the contrast media when evaluating the contrast effect, and it is essential to use the same contrast media for each examination, or the renal excretory speed will be under/overestimated

  14. Stability of Balloon-Retention Gastrostomy Tubes with Different Concentrations of Contrast Material: In Vitro Study

    International Nuclear Information System (INIS)

    Lopera, Jorge E.; Alvarez, Alex; Trimmer, Clayton; Josephs, Shellie; Anderson, Matthew; Dolmatch, Bart

    2009-01-01

    The purpose of this study was to determine the performance of two balloon-retention-type gastrostomy tubes when the balloons are inflated with two types of contrast materials at different concentrations. Two commonly used balloon-retention-type tubes (MIC and Tri-Funnel) were inflated to the manufacturer's recommended volumes (4 and 20 cm 3 , respectively) with normal saline or normal saline plus different concentrations of contrast material. Five tubes of each brand were inflated with normal saline and 0%, 25%, 50%, 75%, and 100% contrast material dilutions, using either nonionic hyperosmolar contrast, or nonionic iso-osmolar contrast. The tubes were submerged in a glass basin containing a solution with a pH of 4. Every week the tubes were visually inspected to determine the integrity of the balloons, and the diameter of the balloons was measured with a caliper. The tests were repeated every week for a total of 12 weeks. The MIC balloons deflated slightly faster over time than the Tri-Funnel balloons. The Tri-Funnel balloons remained relatively stable over the study period for the different concentrations of contrast materials. The deflation rates of the MIC balloons were proportionally related to the concentration of saline and inversely related to the concentration of the contrast material. At high contrast material concentrations, solidification of the balloons was observed. In conclusion, this in vitro study confirms that the use of diluted amounts of nonionic contrast materials is safe for inflating the balloons of two types of balloon-retention feeding tubes. High concentrations of contrast could result in solidification of the balloons and should be avoided.

  15. Effects of changes in analytic variables and contrast medium on estimation of glomerular filtration rates by computed tomography in healthy dogs.

    Science.gov (United States)

    Matsuda, Yuri; Kishimoto, Miori; Kushida, Kazuya; Yamada, Kazutaka; Shimizu, Miki; Itoh, Hiroshi

    2017-09-01

    OBJECTIVE To investigate effects of changes in analytic variables and contrast medium osmolality on glomerular filtration rate estimated by CT (CT-GFR) in dogs. ANIMALS 4 healthy anesthetized Beagles. PROCEDURES GFR was estimated by inulin clearance, and dogs underwent CT-GFR with iodinated contrast medium (iohexol or iodixanol) in a crossover-design study. Dynamic renal CT scanning was performed. Patlak plot analysis was used to calculate GFR with the renal cortex or whole kidney selected as the region of interest. The renal cortex was analyzed just prior to time of the second cortical attenuation peak. The whole kidney was analyzed 60, 80, 100, and 120 seconds after the appearance of contrast medium. Automated GFR calculations were performed with preinstalled perfusion software including 2 noise reduction levels (medium and strong). The CT-GFRs were compared with GFR estimated by inulin clearance. RESULTS There was no significant difference in CT-GFR with iohexol versus iodixanol in any analyses. The CT-GFR at the renal cortex, CT-GFR for the whole kidney 60 seconds after appearance of contrast medium, and CT-GFR calculated by perfusion software with medium noise reduction did not differ significantly from GFR estimated by inulin clearance. The CT-GFR was underestimated at ≥ 80 seconds after contrast medium appearance (whole kidney) and when strong noise reduction was used with perfusion CT software. CONCLUSIONS AND CLINICAL RELEVANCE Selection of the renal cortex as region of interest or use of the 60-second time point for whole-kidney evaluation yielded the best CT-GFR results. The perfusion software used produced good results with appropriate noise reduction. IMPACT FOR HUMAN MEDICINE The finding that excessive noise reduction caused underestimation of CT-GFR suggests that this factor should also be considered in CT-GFR examination of human patients.

  16. Which iodinated contrast media is the least cytotoxic to human disc cells?

    Science.gov (United States)

    Kim, Kyung-Hyun; Park, Jeong-Yoon; Park, Hyo-Suk; Kuh, Sung-Uk; Chin, Dong-Kyu; Kim, Keun-Su; Cho, Yong-Eun

    2015-05-01

    Iodinated contrast media (CM) is commonly used for various intradiscal injections such as in discography and endoscopic spinal surgery. However, CM has been shown to be toxic to renal tissue due to its ionic strength and osmolarity and as a result of iodine-induced cytotoxicity, which has raised concern over whether there are similar negative effects on disc cells. This in vitro study was designed to identify the least cytotoxic iodinated CM to the human disc cell among four different physiochemical iodinated contrast dyes. In vitro laboratory study. Intervertebral disc tissue was obtained by discectomy from a total of 10 lumbar disc patients undergoing surgery and disc cells were isolated. The human disc cells were grown in 3D alginate bead culture with 0, 0.1, 10, and 100 mg/mL CM solutions (ionic dimer, ionic monomer, non-ionic dimer, and non-ionic monomer) and mannitol as a control for 2 days. The living cells were analyzed with trypan blue staining. Fluorescence-activated cell sorting analysis was performed using Annexin V and propidium iodide (PI) and 3D alginate bead immunostaining to identify live, apoptotic, and necrotic cells. Human disc cell death was time- and dose-dependent in response to CM and more necrosis was observed than apoptosis. In addition, non-ionic dimeric CM (iodixanol) showed the least toxic effect on human disc cells, followed by non-ionic monomeric (iopromide), ionic dimeric (ioxaglate), and ionic monomeric CM (ioxithalamate). Contrast media is cytotoxic to human disc cells in a dose- and time-dependent manner. This in vitro study revealed that, among four different CM preparations, non-ionic dimeric CM is the least detrimental to human disc cell viability. Careful attention should be paid to the type of CM chosen for discography and endoscopic spinal surgery. It is also necessary to investigate the detrimental effects of CM on disc cells and disc degeneration in further in vivo studies. Copyright © 2015 Elsevier Inc. All rights

  17. Human exposure to non-ionizing radiation and potential adverse health effects

    International Nuclear Information System (INIS)

    Vulevic, B.; Maric, B.; Zivkovic, D.

    1999-01-01

    The problem of protection from the non-ionizing radiation has presented an actual subject in the last twenty years both worldwide and in our country. Great attention has been paid to this problem throughout the world and there is not almost a field of human activities that disregards the effect of non-ionizing radiation to the human health.The object of this work is to point concisely, on the basis of numerous domestic and foreign referential data, to the potential adverse health effects caused by uncontrolled exposure to non-ionizing radiation. (author)

  18. Analytical optimization of digital subtraction mammography with contrast medium using a commercial unit.

    Science.gov (United States)

    Rosado-Méndez, I; Palma, B A; Brandan, M E

    2008-12-01

    Contrast-medium-enhanced digital mammography (CEDM) is an image subtraction technique which might help unmasking lesions embedded in very dense breasts. Previous works have stated the feasibility of CEDM and the imperative need of radiological optimization. This work presents an extension of a former analytical formalism to predict contrast-to-noise ratio (CNR) in subtracted mammograms. The goal is to optimize radiological parameters available in a clinical mammographic unit (x-ray tube anode/filter combination, voltage, and loading) by maximizing CNR and minimizing total mean glandular dose (D(gT)), simulating the experimental application of an iodine-based contrast medium and the image subtraction under dual-energy nontemporal, and single- or dual-energy temporal modalities. Total breast-entrance air kerma is limited to a fixed 8.76 mGy (1 R, similar to screening studies). Mathematical expressions obtained from the formalism are evaluated using computed mammographic x-ray spectra attenuated by an adipose/glandular breast containing an elongated structure filled with an iodinated solution in various concentrations. A systematic study of contrast, its associated variance, and CNR for different spectral combinations is performed, concluding in the proposal of optimum x-ray spectra. The linearity between contrast in subtracted images and iodine mass thickness is proven, including the determination of iodine visualization limits based on Rose's detection criterion. Finally, total breast-entrance air kerma is distributed between both images in various proportions in order to maximize the figure of merit CNR2/D(gT). Predicted results indicate the advantage of temporal subtraction (either single- or dual-energy modalities) with optimum parameters corresponding to high-voltage, strongly hardened Rh/Rh spectra. For temporal techniques, CNR was found to depend mostly on the energy of the iodinated image, and thus reduction in D(gT) could be achieved if the spectral energy

  19. Synthesis and in vitro evaluation of bone-seeking superparamagnetic iron oxide nanoparticles as contrast agents for imaging bone metabolic activity.

    Science.gov (United States)

    Panahifar, Arash; Mahmoudi, Morteza; Doschak, Michael R

    2013-06-12

    In this article, we report the synthesis and in vitro evaluation of a new class of nonionizing bone-targeting contrast agents based on bisphosphonate-conjugated superparamagnetic iron oxide nanoparticles (SPIONs), for use in imaging of bone turnover with magnetic resonance imaging (MRI). Similar to bone-targeting (99m)Technetium medronate, our novel contrast agent uses bisphosphonates to impart bone-seeking properties, but replaces the former radioisotope with nonionizing SPIONs which enables their subsequent detection using MRI. Our reported method is relatively simple, quick and cost-effective and results in BP-SPIONs with a final nanoparticle size of 17 nm under electron microscopy technique (i.e., TEM). In-vitro binding studies of our novel bone tracer have shown selective binding affinity (around 65%) for hydroxyapatite, the principal mineral of bone. Bone-targeting SPIONs offer the potential for use as nonionizing MRI contrast agents capable of imaging dynamic bone turnover, for use in the diagnosis and monitoring of metabolic bone diseases and related bone pathology.

  20. Complex phase behavior in solvent-free nonionic surfactants

    DEFF Research Database (Denmark)

    Hillmyer, M.A.; Bates, F.S.; Almdal, K.

    1996-01-01

    Unsolvated block copolymers and surfactant solutions are ''soft materials'' that share a common set of ordered microstructures, A set of polyethyleneoxide-polyethylethylene (PEG-PEE) block copolymers that are chemically similar to the well-known alkane-oxyethylene (C(n)EO(m)) nonionic surfactants...... was synthesized here. The general phase behavior in these materials resembles that of both higher molecular weight block copolymers and lower molecular weight nonionic surfactant solutions. Two of the block copolymers exhibited thermally induced order-order transitions and were studied in detail by small...

  1. Magnetic Resonance Imaging in degenerative disease of the lumbar spine: Fat Saturation technique and contrast medium.

    Science.gov (United States)

    D'Aprile, Paola; Nasuto, Michelangelo; Tarantino, Alfredo; Cornacchia, Samantha; Guglielmi, Giuseppe; Jinkins, J Randy

    2018-01-19

    To examine both anterior and posterior elements of the lumbar spine in patients with low back pain using MRI T2-weighted sequences with Fat Saturation (FS) and contrast enhanced T1-weighted sequences with FS. Two thousand eight hundred and twenty (2820) patients (1628 male, 1192 female, mean age 54) presenting low back pain underwent MRI standard examination (Sagittal T1w TSE and T2w TSE, axial T1 SE) with the addition of sagittal and axial T2w Fat Sat (FS) sequences. Among all the patients, 987 (35%) have been studied adding Contrast Enhanced (CE) T1w FS sequences after administration of contrast medium. Among 987 patients studied with contrast medium, we found: active-inflammatory intervertebral osteochondrosis in 646 (65%) patients; degenerative-inflammatory changes in facet joints (facet joint effusion, synovitis, synovial cysts) in 462 (47%); spondylolysis in 69 (7%); degenerative-inflammatory changes of the flava, interspinous and supraspinous ligaments in 245 (25%); inflammatory changes of posterior perispinal muscles in 84 (8%) patients. In patients with suspected no-disc-related low back pain, the implementation of T2w FS and CE T1w FS sequences to the standard MR protocol could allow a better identification of degenerative-inflammatory changes more likely associated to the pain.

  2. A case of pulmonary edema developed after intraarterial injection of iodinated contrast medium

    International Nuclear Information System (INIS)

    Min, Byoung Chol; Chun, Kang Woo; Koh, Jae Hyu; Yoon, Jong Sup

    1982-01-01

    Pulmonary edema is a rare adverse reaction to the iodinated contrast medium. Complaining of huge abdominal mass, a 52 years old female was admitted to the Hangang Sungsim Hospital. On physical examination, the patient appeared to be healthy. She had stable vital signs, i.e. BP: 120/80 mmHg, pulse rate: 80/min.etc. An adult head sized mass was palpated in the left mid and lower abdomen. Otherwise nonspecific. On laboratory studies the positive findings were 8-10 WBC/HPF in urine, 25.6 mg/dl for BUN and PVC in EKG. It was negative for urine protein, serum creatinline and liver function test. We injected 100 ml and 30 ml of Urografin 60 through the abdominal aorta dividing 3 times and major branches of the abdominal aorta, respectively. Immediately after complicating angiography, interstitial pulmonary edema was found, showing blurring of the vascular margins, perivascular haziness and thickening of the interlobular septal lines in the both lower lung fields. The blood pressure was dropped to 80/60 mmHg, but pulse rate was normal. She did not complain of dyspnea, and cyanosis was not developed. The urine volume was normally maintained. She was treated for pulmonary edema, which was completely absorbed after 20 hours. And the blood pressure was also normalized. We have experienced a case of pulmonary edema developed after intraarterial injection of the iodinated contrast medium without underlying cardiac, renal and hepatic problems, and reviewed the literatures on mechanisms of pulmonary edema caused by intravascular injection of the iodinated contrast materials

  3. Angiocardiographic technique of congenital heart disease in children

    International Nuclear Information System (INIS)

    Zhu Ming; Zhai Hongyuan; Zhong Yumin

    2005-01-01

    Objective: To evaluate different angiocardiographic techniques of congenital heart disease in children. Methods: 11045 pediatric patients with congenital heart disease were performed angiocardiography using cut film, cine film and digital subtraction angiography (DSA) equipment. Different angiocardiographic techniques were used. Results: The diagnostic accuracy of cut film with conventional AP and lateral views was 80.5%, the diagnostic accuracy of cine film with angulated views was 90.0% and the diagnostic accuracy of DSA using non-ionic contrast medium with angulated views was 96.5%. Conclusion: Dynamic picture angiography with digital subtraction using non-ionic contrast medium under rapid injection is the key for claiming the high quality imaging diagnosis of congenital heart disease in children. (authors)

  4. Abdominal multi-detector row CT: Effectiveness of determining contrast medium dose on basis of body surface area

    International Nuclear Information System (INIS)

    Onishi, Hiromitsu; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Osuga, Keigo; Tatsumi, Mitsuaki; Higashihara, Hiroki; Maeda, Noboru; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tomoda, Kaname; Tomiyama, Noriyuki

    2011-01-01

    Purpose: To investigate the validity of determining the contrast medium dose based on body surface area (BSA) for the abdominal contrast-enhanced multi-detector row CT comparing with determining based on body weight (BW). Materials and methods: Institutional review committee approval was obtained. In this retrospective study, 191 patients those underwent abdominal contrast-enhanced multi-detector row CT were enrolled. All patients received 96 mL of 320 mg I/mL contrast medium at the rate of 3.2 mL. The iodine dose required to enhance 1 HU of the aorta at the arterial phase and that of liver parenchyma at portal venous phase per BSA were calculated (EU BSA ) and evaluated the relationship with BSA. Those per BW were also calculated (EU BW ) and evaluated. Estimated enhancement values (EEVs) of the aorta and liver parenchyma with two protocols for dose decision based on BSA and BW were calculated and patient-to-patient variability was compared between two protocols using the Levene test. Results: The mean of EU BSA and EU BW were 0.0621 g I/m 2 /HU and 0.00178 g I/kg/HU for the aorta, and 0.342 g I/m 2 /HU and 0.00978 g I/kg/HU for the liver parenchyma, respectively. In the aortic enhancement, EU BSA was almost constant regardless of BSA, and the mean absolute deviation of the EEV with the BSA protocol was significantly lower than that with the BW protocol (P < .001), although there was no significant difference between two protocols in the hepatic parenchymal enhancement (P = .92). Conclusion: For the aortic enhancement, determining the contrast medium dose based on BSA was considered to improve patient-to-patient enhancement variability.

  5. Cytogenetic effects of cardioangiography on blood lymphocytes in children and in vitro effects of contrast medium and low dose radiation

    International Nuclear Information System (INIS)

    Nikula, E.; Kiviniitty, K.

    1987-01-01

    Structural chromosome aberrations were analysed in the peripheral blood lymphocytes of 15 children, aged 1 to 13 years, before, immediately after, 24 hours after and 6 to 8 months after cardioangiographic examination. Statistically significant increases were only demonstrated in the frequency of gaps and, consequently, in the frequency of aberrant cells immediately after cardioangiography. Most of the chromosome damage clearly disappeared within 24 hours. In addition, whole blood cultures were exposed in vitro to low dose radiation, a contrast medium, and radiation together with the contrast medium. No statistically significant differences could be observed in the chromosome aberration frequencies. It was concluded that the modern radiographic procedure, which uses very low radiation doses and less contrast medium, does not cause a consistent, permanent increase of chromosomal damage in the lymphocytes of children. However, the situation may be different if the child undergoes many radiography examinations or the radiation doses are high. (orig./MG)

  6. Anaphylactic reaction to iodinated contrast media. Review the relevant loterature

    International Nuclear Information System (INIS)

    Kuwashima, Shigeko; Kitajima, Kazuhiro; Kohno, Tatsuo; Kaji, Yasushi; Takahashi, Tetuya; Seki, Masaya; Sakamoto, Tomoyuki

    2007-01-01

    Recently, iodinated contrast media are necessary for CT examinations and they occupy an important position in the radiological diagnosis. Nonionic contrast media significantly reduce the prevalence of all degree of adverse reaction to contrast media rather than ionic contrast media. So, generally, iodinated contrast media are safe and widely used, but adverse reaction after intravenous iodinated contrast media are not uncommon. Severe and potentially life-threatening reaction occur by using the iodinated contrast media practically. Patients at risk must be identified before the contrast media study, and all possible measures must be taken to deal effectively with spontaneous anaphylactic reactions. We report three cases of anaphylactic reactions by iodinated contrast media on CT. (author)

  7. Polysorbate 80 and low-osmolality water-soluble contrast medium enema in diagnosis and treatment of faecal obstruction in malignant phaeochromocytoma

    International Nuclear Information System (INIS)

    Ratcliffe, J.F.

    1986-01-01

    Stercoral obstruction in a young woman with disseminated phaeochromocytoma was diagnosed and treated successfully using an enema of isosmolar iohexol (Omnipaque) and 1% polysorbate 80 (Tween 80) without complication. Surgical intervention was thus avoided. A low osmolality water-soluble contrast medium (iohexol 150 mg I/ml) with a wetting agent (1% Tween 80) was used because a barium suspension would have inspissated, exacerbating the constipation and a hyperosmolar contrast medium might have precipitated a hypertensive crisis and destablished her critical salt and water balance. (orig.)

  8. Perforations during contrast enema

    International Nuclear Information System (INIS)

    Vogel, H.; Steinkamp, U.; Grabbe, E.; Allgemeines Krankenhaus Ochsenzoll, Hamburg

    1983-01-01

    During contrast enema, perforation into the retroperitoneal space can be differentiated from perforation into the peritoneum and perforation into the intestinal wall associated with formation of barium granulomas or submucosal spreading of the contrast medium. Other special forms are perforation with contrast medium embolism of diverticula; of the processus vermiformis; penetration of contrast medium into fistulous systems and from the operated areas. Risk factors are: balloon catheter, intestinal tubes with a hard tip, preternatural anus, excessive enema pressure, contrast medium additions, preceding manipulations, intestinal diseases, advanced age and delegation of manipulations to assistants and unskilled staff. Children are particularly at risk. (orig.) [de

  9. Contrast induced nephropathy

    DEFF Research Database (Denmark)

    Stacul, Fulvio; van der Molen, Aart J; Reimer, Peter

    2011-01-01

    PURPOSE: The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 1999 guidelines on contrast medium-induced nephropathy (CIN). AREAS COVERED: Topics reviewed include the definition of CIN, the choice of contrast medium, the prophylactic me...

  10. Ionizing and Nonionizing Radiation Protection. Module SH-35. Safety and Health.

    Science.gov (United States)

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on ionizing and nonionizing radiation protection is one of 50 modules concerned with job safety and health. This module describes various types of ionizing and nonionizing radiation, and the situations in the workplace where potential hazards from radiation may exist. Following the introduction, 13 objectives (each keyed to a…

  11. Nuclear magnetic resonance diagnosis of cerebral tumours with the use of the contrast medium gadolinium-DTPA

    International Nuclear Information System (INIS)

    Schoerner, W.; Felix, R.; Claussen, C.; Fiegler, W.; Kazner, E.; Speck, U.; Niendorf, H.P.

    1984-01-01

    This study examines the effect of the NMR contrast medium gadolinium-DTPA on image contrast in cerebral tumours. Sixteen patients with space-occupying cerebral lesions were examined on a 0.35 Tesla superconducting scanner, using a T1-weighted spinecho sequence prior to and after the intravenous application of gadolinium-DTPA. In 8 patients T2-weighted spinecho-sequences were obtained before the administration of contrast. The tomograms were evaluated visually and according to quantitative criteria. The use of gadolinium-DTPA helps to evaluate the blood-brain barrier and improves diagnosis by differentiating tumour tissue from edema and from normal brain tissue. (orig.) [de

  12. Magnetic susceptibility imaging with a nonionic contrast agent

    International Nuclear Information System (INIS)

    Cacheris, W.; Rocklage, S.M.; Quay, S.; Dow, W.; Love, D.; Worah, D.; Lim, K.

    1988-01-01

    The magnetic susceptibility mechanism for MR imaging contrast enhancement has the advantage of providing useful information, such as cerebral blood flow, without crossing the blood-brain barrier. In this paper the authors report the use of a highly effective, relatively nontoxic chelate as a magnetic susceptibility agent. Dy-DTPA-bis(methylamide) (Dy-DTPA-BMA) has an extremely low acute toxicity (LD-50, intravenous, mice ∼ 40 mmol/kg). Doses of 1 mmol/kg and 2 mmol/kg Dy-DTPA-BMA lowered the initial signal intensity 63% to 57%, respectively. The utility of this technique in detecting areas of reduced blood flow within the brain was demonstrated by imaging a rabbit with a cerebral perfusion deficit

  13. The effect of ionic and non-ionic surfactants on the growth, nitrate reductase and nitrite reductase activities of Spirodela polyrrhiza (L. Schleiden

    Directory of Open Access Journals (Sweden)

    Józef Buczek

    2014-01-01

    Full Text Available Inclusion into the medium of 5 mg•dm-3 of non-ionic (ENF or ionic (DBST surfactant caused 50-60% inhibition of nitrite reductase MR activity in S. polyrrhiza. At the same time, increased accumulation of NO2- in the plant tissues and lowering of the total and soluble protein contents were found. DBST also lowered the nitrate reductase (NR activity and the dry mass of the plants.

  14. Technical sheets of ionizing radiations. 2. Non-ionizing radiations

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    The biological effects of different non-ionizing radiations are studied: ultra-violet radiation, visible radiation, infrared radiation, micrometric waves, ultrasonics. In spite of their apparent diversity these radiations are similar in their physico-chemical effects, but in view of their widely varying production methods and types of application each type is considered separately. It is pointed out that no organization resembling the CIPR exists in the field of non-ionizing radiations, the result being a great disparity amongst the different legislations in force [fr

  15. Renal Safety of Iodinated Contrast Media Depending on Their Osmolarity – Current Outlooks

    International Nuclear Information System (INIS)

    Mruk, Bartosz

    2016-01-01

    Iodinated contrast media (ICM) are commonly administered pharmaceutical agents. Most often they are used intravenously and intraarterially. Although iodinated contrast agents are relatively safe and widely used, adverse events occur and questions remain about their use, safety, and interactions. The most important adverse effects of contrast media include hypersensitivity reactions, thyroid dysfunction, and contrast-induced nephropathy. Radiologists must be aware of the risk factors for reactions to contrast media. Nonionic iodinated contrast agents can be divided into monomeric, low-osmolar, and dimeric, iso-osmolar classes. The osmotic characteristics of contrast media have been a significant focus in many investigations of contrast-induced nephropathy

  16. Contrast medium-induced nephropathy: the pathophysiology

    DEFF Research Database (Denmark)

    Persson, P B; Tepel, Martin

    2006-01-01

    A widespread, rather general, definition of contrast-induced nephropathy (CIN) is an impairment in renal function occurring within 3 days following the intravascular administration of contrast media (CM) and the absence of an alternative aetiology. In spite of the vast clinical importance of CIN...... haemodynamics, regional hypoxia, auto-, and paracrine factors (adenosine, endothelin, reactive oxygen species) to direct cytotoxic effects. Although these potential mediators of CIN will be discussed separately, several factors may act in concert to perturb kidney function after exposure to contrast media. From...... the current knowledge of the mechanisms causing CIN, it is not possible to recommend a certain class of contrast media, except to avoid large doses of CM of the first generation. From a pathophysiological perspective, volume expansion is effective in avoiding CIN, since water permeability of the collecting...

  17. Effects of contrast agents on the fallopian tube in a rabbit model

    International Nuclear Information System (INIS)

    Moore, D.E.

    1989-01-01

    Selection of the optimal contrast agent for hysterosalpingography was the focus of this study. The authors have evaluated the effect of different iodinated contrast agents on the fallopian tube of a rabbit. Ethiodol (oil-soluble contrast agent), methylglucamine iothalomate (water-soluble ionic agent) 30% and 60%, and Ioxilan (water-soluble monionic contrast agent) were compared. The agents were introduced by fallopian tube catheterization. Findings suggested that nonionic water-soluble contrast agents were the least detrimental to the fallopian tube and surrounding tissue. Iothalomate 60% resulted in mild inflammatory changes. Oil-soluble contrast agents caused granulomatous reaction and fibrinous adhesions

  18. Vascularization of liver tumors - preliminary results with Coded Harmonic Angio (CHA), phase inversion imaging, 3D power Doppler and contrast medium-enhanced B-flow with second generation contrast agent (Optison).

    Science.gov (United States)

    Jung, E M; Kubale, R; Jungius, K-P; Jung, W; Lenhart, M; Clevert, D-A

    2006-01-01

    To investigate the dynamic value of contrast medium-enhanced ultrasonography with Optison for appraisal of the vascularization of hepatic tumors using harmonic imaging, 3D-/power Doppler and B-flow. 60 patients with a mean age of 56 years (range 35-76 years) with 93 liver tumors, including histopathologically proven hepatocellular carcinoma (HCC) [15 cases with 20 lesions], liver metastases of colorectal tumors [17 cases with 33 lesions], metastases of breast cancer [10 cases with 21 lesions] and hemangiomas [10 cases with 19 lesions] were prospectively investigated by means of multislice CT as well as native and contrast medium-enhanced ultrasound using a multifrequency transducer (2.5-4 MHz, Logig 9, GE). B scan was performed with additional color and power Doppler, followed by a bolus injection of 0.5 ml Optison. Tumor vascularization was evaluated with coded harmonic angio (CHA), pulse inversion imaging with power Doppler, 3D power Doppler and in the late phase (>5 min) with B-flow. In 15 cases with HCC, i.a. DSA was performed in addition. The results were also correlated with MRT and histological findings. Compared to spiral-CT/MRT, only 72/93 (77%) of the lesions could be detected in the B scan, 75/93 (81%) with CHA and 93/93 (100%) in the pulse inversion mode. Tumor vascularization was detectable in 43/93 (46%) of lesions with native power Doppler, in 75/93 (81%) of lesions after administering contrast medium in the CHA mode, in 81/93 (87%) of lesions in the pulse inversion mode with power Doppler and in 77/93 (83%) of lesions with contrast-enhanced B-flow. Early arterial and capillary perfusion was best detected with CHA, particularly in 20/20 (100%) of the HCC lesions, allowing a 3D reconstruction. 3D power Doppler was especially useful in investigating the tumor margins. Up to 20 min after contrast medium injection, B-flow was capable of detecting increased metastatic tumor vascularization in 42/54 (78%) of cases and intratumoral perfusion in 17/20 (85

  19. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.

    2005-01-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  20. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [Copenhagen University Hospital, Herlev (Denmark). Department of Diagnostic Radiology; Morcos, Sameh K. [Northern General Hospital, Department of Diagnostic Imaging, Sheffield Teaching Hospitals NHS Trust, Sheffield (United Kingdom)

    2005-04-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  1. The influence of different contrast medium concentrations and injection protocols on quantitative and clinical assessment of FDG–PET/CT in lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Verburg, Frederik A., E-mail: fverburg@ukaachen.de [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Kuhl, Christiane K. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Pietsch, Hubertus [Bayer Pharma AG, Berlin, Müllerstrasse 178, 13353 Berlin (Germany); Palmowski, Moritz [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Mottaghy, Felix M. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Behrendt, Florian F. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany)

    2013-10-01

    Objectives: To compare the effects of two different contrast medium concentrations for use in computed X-ray tomography (CT) employing two different injection protocols on positron emission tomography (PET) reconstruction in combined 2-{sup 18}F-desoxyglucose (FDG) PET/CT in patients with a suspicion of lung cancer. Methods: 120 patients with a suspicion of lung cancer were enrolled prospectively. PET images were reconstructed with the non-enhanced and venous phase contrast CT obtained after injection of iopromide 300 mg/ml or 370 mg/ml using either a fixed-dose or a body surface area adapted injection protocol. Maximum and mean standardized uptake values (SUVmax and SUVmean) and contrast enhancement (HU) were determined in the subclavian vein, ascending aorta, abdominal aorta, inferior vena cava, portal vein, liver and kidney and in the suspicious lung lesion. PET data were evaluated visually for the presence of malignancy and image quality. Results: At none of the sites a significant difference in the extent of the contrast enhancement between the four different protocols was found. However, the variability of the contrast enhancement at several anatomical sites was significantly greater in the fixed dose groups than in the BSA groups for both contrast medium concentrations. At none of the sites a significant difference was found in the extent of the SUVmax and SUVmean increase as a result of the use of the venous phase contrast enhanced CT for attenuation. Visual clinical evaluation of lesions showed no differences between contrast and non-contrast PET/CT (P = 0.32). Conclusions: Contrast enhanced CT for attenuation correction in combined PET/CT in lung cancer affects neither the clinical assessment nor image quality of the PET-images. A body surface adapted contrast medium protocol reduces the interpatient variability in contrast enhancement.

  2. Effects of high iodine doses given parenterally as contrast medium on parameter of the pro/antioxidative balance

    International Nuclear Information System (INIS)

    Winkler, R.; Griebenow, S.; Scheidleder, B.; Bailer, H.

    2002-01-01

    The aim of this study was to investigate effects of high iodine doses given parenterally as contrast medium on parameters of lipid status and thyroid hormone status as well as on parameters of the pro/antioxidative balance of spa patients. 29 patients with a comparable indication who had to undergo an angiography were chosen. The blood parameters of these patients were determined before and after the angiographic treatment. No provable changes of the thyroid parameters f-T 3 , f-T 4 and TSH were found after the angiography. In case of enzyme activities, the protective enzymes SOD and GSHPX showed no changes, while the concentrations of peroxides and MDA were increased significantly. Corresponding to this, the total antioxidative status and the vitamin E level decreased significantly. Altogether these results stand for a moderate deterioration of the antioxidative protective potential by the highly iodine containing contrast medium. (author)

  3. The use of dilute calogen[reg] as a fat density oral contrast medium in upper abdominal computed tomography, compared with the use of water and positive oral contrast media

    International Nuclear Information System (INIS)

    Ramsay, Duncan W.; Markham, Derrian H.; Morgan, Bruno; Rodgers, Peter M.; Liddicoat, Amanda J.

    2001-01-01

    AIM: Oral contrast media are commonly given prior to computed tomography (CT) examination of the upper abdomen. Although positive oral contrast media are normally used, there is increasing interest in using negative agents such as water and less commonly fat density products. The aim of this study was to compare a positive oral contrast medium, water, and a diluted emulsion of arachis oil (Calogen[reg], a fat density food supplement) for assessment of the upper abdomen. MATERIALS AND METHODS: Seventy-one patients referred for upper abdominal CT were randomized to receive either 500 ml water, 2% sodium diatrizoate or a dilute suspension of Calogen[reg]. The CT images were scored independently by three radiologists. Distension and anatomical identification was assessed for the stomach, duodenum and jejunum; with anatomical identification recorded for the pancreas, retroperitoneum, liver, gallbladder and spleen. RESULTS: Dilute Calogen[reg] produced a significant improvement (P < 0.01) in distension and anatomical visualization of the stomach and proximal duodenum. Only minimal differences were demonstrated between the three contrast media for visualization of more distal small bowel or identification of the other upper abdominal viscera. Significantly more artifacts were caused by positive contrast media than with the Calogen[reg] mixture. CONCLUSION: A dilute suspension of Calogen[reg] as an oral contrast medium is recommended when disease is suspected within the stomach or proximal duodenum. Ramsay, D.W. et al. (2001)

  4. Non-ionizing radiation protection training manual for radiation control. Lectures, demonstrations, laboratories and tours on the course on non-ionizing radiations. Final report

    International Nuclear Information System (INIS)

    Morgan, K.Z.; Burkhart, R.L.

    1976-03-01

    In late 1974, consultation with the National Training Coordination Committee of the Conference of Radiation Control Program Directors determined that State personnel needed training in order to fulfill their responsibility with respect to the growing number of non-ionizing radiation sources. A contract was awarded to the Georgia Institute of Technology to develop materials for a training program on non-ionizing radiation protection, pilot test these materials in a two-week presentation for Federal, State, and local government health personnel, and revise the materials as needed to produce a self-contained training manual. The materials were pilot-tested in March 1976, and then revised to provide the final manual. The course consists of three parts (1) general discussions of basic principles, properties, propagation and behavior of all types of non-ionizing radiations (2) an indepth study of all types and applications of coherent (laser) radiations, and (3) a study of ultraviolet, infrared, microwave, r.f., longwave and mechanical radiations as they may be used to have applications in hospitals and other medical institutions

  5. Nonionizing radiation and health

    International Nuclear Information System (INIS)

    Suess, M.J.

    1985-01-01

    While a great deal of work has been done by international bodies to establish permissible levels for ionizing radiation, much less attention has been paid to the nonionizing forms of radiation and their possible health effects. Taking into account that equipment producing such radiation is now widely used both in the house and in industry, the paper presents the possible health effects of ultraviolet, visible, laser, infrared and microwave radiation, of electric and magnetic fields and of the ultrasound waves

  6. Estimation of shear velocity contrast for dipping or anisotropic medium from transmitted Ps amplitude variation with ray-parameter

    Science.gov (United States)

    Kumar, Prakash

    2015-12-01

    Amplitude versus offset analysis of P to P reflection is often used in exploration seismology for hydrocarbon exploration. In the present work, the feasibility to estimate crustal velocity structure from transmitted P to S wave amplitude variation with ray-parameter has been investigated separately for dipping layer and anisotropy medium. First, for horizontal and isotropic medium, the approximation of P-to-s conversion is used that is expressed as a linear form in terms of slowness. Next, the intercept of the linear regression has been used to estimate the shear wave velocity contrast (δβ) across an interface. The formulation holds good for isotropic and horizontal layer medium. Application of such formula to anisotropic medium or dipping layer data may lead to erroneous estimation of δβ. In order to overcome this problem, a method has been proposed to compensate the SV-amplitude using shifted version of SH-amplitude, and subsequently transforming SV amplitudes equivalent to that from isotropic or horizontal layer medium as the case may be. Once this transformation has been done, δβ can be estimated using isotropic horizontal layer formula. The shifts required in SH for the compensation are π/2 and π/4 for dipping layer and anisotropic medium, respectively. The effectiveness of the approach has been reported using various synthetic data sets. The methodology is also tested on real data from HI-CLIMB network in Himalaya, where the presence of dipping Moho has already been reported. The result reveals that the average shear wave velocity contrast across the Moho is larger towards the Indian side compared to the higher Himalayan and Tibetan regions.

  7. Iohexol and diatrizoate: comparison in visceral arteriography

    International Nuclear Information System (INIS)

    Adam, A.; Hemingway, A.P.; Allison, D.J.

    1985-01-01

    Iohexol, a low osmolality, nonionic contrast medium, and diatrizoate, a conventional ionic contrast medium, were evaluated for patient tolerance during visceral arteriography. Almost all the procedures performed with iohexol were painless: most patients given this agent reported only a mild feeling of warmth. Diatrizoate produced some pain and a feeling of intense heat in most patients. Both media produced excellent radiographic results and no serious adverse reactions occurred

  8. Studies on the consistency of internally taken contrast medium for pancreas CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Kishio; Mimura, Seiichi; Tahara, Seiji; Kitayama, Takuichi; Inamura, Keiji; Mikami, Yasutaka; Hashimoto, Keiji; Hiraki, Yoshio; Aono, Kaname

    1985-02-01

    A problem of Pancreatic CT scanning is the discrimination between the pancreas and the adjacent gastrointestinal tract. Generally we administer a dilution of gastrografin internally to make the discrimination. The degree of dilution has been decided by experience at each hospital. When the consistency of the contrast medium is low in density, an enhancement effect cannot be expected, but when the consistency is high, artifacts appear. We have experimented on the degree of the dilution and CT-No to decide the optimum consistency of gastrografin for the diagnosis of pancreatic disease. Statistical analysis of the results show the optimum dilution of gastrografin to be 1.5%.

  9. Non-ionizing radiations : physical characteristics, biological effects and health hazard assessment

    International Nuclear Information System (INIS)

    Repacholi, M.H.

    1988-01-01

    The Workshop was a project of the International Non-Ionizing Radiation Committee of IRPA and comprised a series of educational lectures and demonstrations intended to give a comprehensive overview of non-ionizing electromagnetic radiation: physical characteristics, sources of concern, levels of exposure, mechanisms of interaction and reported effects of these fields and radiations with biological tissues, human studies, health risk assessment, national and international standards and guidelines, and protective measures

  10. Dialysis and contrast media

    International Nuclear Information System (INIS)

    Morcos, Sameh K.; Thomsen, Henrik S.; Webb, Judith A.W.

    2002-01-01

    In a previous survey we revealed uncertainty among responders about (a) whether or not to perform hemodialysis in patients with severely reduced renal function who had received contrast medium; and (b) when to perform hemodialysis in patients on regular treatment with hemodialysis or continuous ambulatory dialysis who received contrast medium. Therefore, the Contrast Media Safety Committee of The European Society of Urogenital Radiology decided to review the literature and to issue guidelines. The committee performed a Medline search. Based on this, a report and guidelines were prepared. The report was discussed at the Ninth European Symposium on Urogenital Radiology in Genoa, Italy. Hemodialysis and peritoneal dialysis safely remove both iodinated and gadolinium-based contrast media. The effectiveness of hemodialysis depends on many factors including blood and dialysate flow rate, permeability of dialysis membrane, duration of hemodialysis and molecular size, protein binding, hydrophilicity, and electrical charge of the contrast medium. Generally, several hemodialysis sessions are needed to removal all contrast medium, whereas it takes 3 weeks for continuous ambulatory dialysis to remove the agent completely. There is no need to schedule the dialysis in relation to the injection of iodinated or MR contrast media or the injection of contrast agent in relation to the dialysis program. Hemodialysis does not protect poorly functioning kidneys against contrast-medium-induced nephrotoxicity. Simple guidelines are given. (orig.)

  11. 29 CFR 1910.97 - Nonionizing radiation.

    Science.gov (United States)

    2010-07-01

    ... electromagnetic energy or in which the cross section of the body is smaller than the cross section of the incident... Warning Symbol (4) Scope. This section applies to all radiations originating from radio stations, radar... 29 Labor 5 2010-07-01 2010-07-01 false Nonionizing radiation. 1910.97 Section 1910.97 Labor...

  12. Iohexol compared with metrizoate in urography

    International Nuclear Information System (INIS)

    Levorstad, K.; Kolbenstvedt, A.; Loeyning, E.W.

    1983-01-01

    Urography was performed in 20 patients using the new non-ionic contrast medium iohexol (Omnipaque) and in 22 patients using the conventional ionic medium metrizoate (Isopaque) in a randomized, double blind comparison. Iohexol caused significantly less subjective reactions and less tachycardia than metrizoate. No significant difference between the contrast media was observed regarding the influence on blood pressure, hematologic parameters, or clinical chemical parameters in blood and urine. Urographic films of similar and high quality were obtained with both contrast media. (Auth.)

  13. [Ionizing and non-ionizing radiation (comparative risk estimations)].

    Science.gov (United States)

    Grigor'ev, Iu G

    2012-01-01

    The population has widely used mobile communication for already more than 15 years. It is important to note that the use of mobile communication has sharply changed the conditions of daily exposure of the population to EME We expose our brain daily for the first time in the entire civilization. The mobile phone is an open and uncontrollable source of electromagnetic radiation. The comparative risk estimation for the population of ionizing and non-ionizing radiation was carried out taking into account the real conditions of influence. Comparison of risks for the population of ionizing and non-ionizing radiation leads us to a conclusion that EMF RF exposure in conditions of wide use of mobile communication is potentially more harmful than ionizing radiation influence.

  14. Multi-detector CT urography: effect of oral hydration and contrast medium volume on renal parenchymal enhancement and urinary tract opacification - a quantitative and qualitative analysis

    International Nuclear Information System (INIS)

    Szolar, Dieter H.; Tillich, Manfred; Preidler, Klaus W.

    2010-01-01

    To assess the effect of oral hydration and contrast-medium volume on renal enhancement and urinary tract opacification in multi-detector CT urography. A total of 192 patients were assigned to different protocols with varying doses of contrast agent with and without oral hydration. The attenuation was measured in the renal parenchyma in the unenhanced, nephrographic and excretory phase, and in the urinary tract in excretory phase imaging, respectively. Opacification of the urinary tract was graded on volume rendered images. Oral hydration did not significantly alter renal parenchymal enhancement in both the nephrographic and the excretory phase (p > 0.001), but significantly decreased mean attenuation of the urinary tract in the excretory phase (p ≤ 0.001), and improved continuous opacification of all ureter segments (p < 0.01). Higher volumes of contrast medium improved renal parenchymal enhancement (p ≤ 0.001) and continuous opacification of the urinary tract (p ≤ 0.01). Oral hydration leads to lower attenuation values in the urinary tract but improves the continuous opacification of the tract. Increase in contrast medium volume leads to higher renal parenchymal enhancement as well as to an increased continuous opacification of the urinary tract. Decrease in contrast medium volume cannot be compensated for by oral hydration in terms of parenchymal enhancement. (orig.)

  15. The effect of newer water-soluble contrast media on I-131 uptake by the thyroid gland

    International Nuclear Information System (INIS)

    Starinsky, R.; Horne, T.; Barr, J.; Ramot, Y.

    2006-01-01

    The aim of this study was to evaluate the effect of two water-soluble contrast media (nonionic and Dimer) on iodine uptake by the thyroid gland. Twenty-eight euthyroid patients (16 females and 12 males) were subjected to 24hrs radioiodine uptake (RAIU) studies following brain CT examinations using the above cited two water-soluble contrast media. Radioiodine uptake studies were done at one (Group-1), two (Group-2) and four (Group-3) weeks following performance of contrast enhanced CT scans. The effect of both contrast media on the thyroid uptake was found to be identical. The radio active iodine uptake (RAIU) was observed to be suppressed in 30% of patients in Group-1, 33% of patients in Group-2 and in none of the patients belonging to Group-3. On the basis of this pilot study on a limited number of patients it was concluded that dimer and non-ionic water soluble contrast media cause suppression of radio iodine uptake by the thyroid gland in a significant proportion of patients. It has also been observed that both contrast media have similar suppressive effects on radio iodine uptake by the thyroid gland. This effect is transient and does not persist beyond a period of four weeks following the administration of the contrast media. (author)

  16. Evaluation of the acute adverse reaction of contrast medium with high and moderate iodine concentration in patients undergoing computed tomography

    International Nuclear Information System (INIS)

    Nagamoto, Masashi; Gomi, Tatsuya; Terada, Hitoshi; Terada, Shigehiko; Kohda, Eiichi

    2006-01-01

    The aim of this prospective study was to evaluate and compare acute adverse reactions between contrast medium containing moderate and high concentrations of iodine in patients undergoing computed tomography (CT). A total of 945 patients undergoing enhanced CT were randomly assigned to receive one of two doses of contrast medium. We then prospectively investigated the incidence of adverse reactions. Iopamidol was used as the contrast medium, with a high concentration of 370 mgI/ml and a moderate concentration of 300 mgI/ml. The frequency of adverse reactions, such as pain at the injection site and heat sensation, were determined. Acute adverse reactions were observed in 2.4% (11/458) of the moderate-concentration group compared to 3.11% (15/482) of the high-concentration group; there was no significant difference in incidence between the two groups. Most adverse reactions were mild, and there was no significant difference in severity. One patient in the high-concentration group was seen to have a moderate adverse reaction. No correlation existed between the incidence of adverse reactions and patient characteristics such as sex, age, weight, flow amount, and flow rate. The incidence of pain was not significantly different between the two groups. In contrast, the incidence of heat sensation was significantly higher in the high-concentration group. The incidence and severity of acute adverse reactions were not significantly different between the two groups, and there were no severe adverse reactions in either group. (author)

  17. Flow-induced immobilization of glucose oxidase in nonionic micellar nanogels for glucose sensing.

    Science.gov (United States)

    Cardiel, Joshua J; Zhao, Ya; Tonggu, Lige; Wang, Liguo; Chung, Jae-Hyun; Shen, Amy Q

    2014-10-21

    A simple microfluidic platform was utilized to immobilize glucose oxidase (GOx) in a nonionic micellar scaffold. The immobilization of GOx was verified by using a combination of cryogenic electron microscopy (cryo-EM), scanning electron microscopy (SEM), and ultraviolet spectroscopy (UV) techniques. Chronoamperometric measurements were conducted on nanogel-GOx scaffolds under different glucose concentrations, exhibiting linear amperometric responses. Without impacting the lifetime and denaturation of GOx, the nonionic nanogel provides a favorable microenvironment for GOx in biological media. This flow-induced immobilization method in a nonionic nanogel host matrix opens up new pathways for designing a simple, fast, biocompatible, and cost-effective process to immobilize biomolecules that are averse to ionic environments.

  18. Effect on thrombus growth and thrombolysis of two types of osmolar contrast media in rabbits

    NARCIS (Netherlands)

    Levi, M. [=Marcel M.; Pascucci, C.; Agnelli, G.; Sturk, A.; Hoek, J.; ten Cate, J. Wouter

    1990-01-01

    Thromboembolic complications have been reported after diagnostic or interventional radiological procedures. However, contrast media inhibit platelet function and blood coagulation in vitro. To investigate these characteristics in vivo, we determined the effect of nonionic and ionic low osmolar

  19. Carbon dioxide DSA: An alternative to nonionic contrast material

    International Nuclear Information System (INIS)

    Hawkins, I.F.; Siragusa, R.; Mietling, S.; Storm, B.; Hawkins, M.; Hirko, R.; Colella, J.

    1987-01-01

    Over the past 6 years the authors have used CO/sub 2/ with DSA as a contrast agent in over 400 cases for arteriography, venography, portography, and opacification of the biliary and urinary tree. The compressibility of the CO/sub 2/ made consistent delivery difficult. Two injectors were designed which reliably delivered the exact amount of the inexpensive CO/sub 2/ which is required. This improved vascular opacification, collateral filling, and tumor AV shunting without any complications or discomfort. Selective renal artery injections were performed in over 20 patients with renal failure without any increase in creatinine. The authors' experience with animals, patients, and the new injectors are illustrated

  20. Dgroup: DG01186 [KEGG MEDICUS

    Lifescience Database Archive (English)

    Full Text Available DG01186 Chemical ... DGroup Gadobenic acid ... D08018 ... Gadobenic acid (INN) D04283 ... Gadobe...nate dimeglumine (USAN); Meglumine gadobenate (JAN) ... ATC code: V08CA08 Non-ionic Contrast medium for NMR-tomography ...

  1. Intracavitary application of contrast medium in the follow-up of complicated tube-drained pleural empyema: Conventional radiography vs CT

    International Nuclear Information System (INIS)

    Duex, M.; Bischoff, H.; Schmaehl, A.; Tuengerthal, S.

    1997-01-01

    Purpose: To define the value of conventional radiography compared with CT in the follow-up of complicated, long-term tube drained pleural empyema after intracavitary application of contrast medium. Methods: 28 patients with complicated pleural empyema (stage III) and longterm tube drainage were submitted to fluoroscopy of the pleural cavity and a CT of the thorax after contrast medium had been instilled into the pleural space. Both examinations were judged by the following criteria: Number and morphology of pleural cavities, quality of drainage and accompanying thoracic disease. Results: 49 pleural cavities were diagnosed. Judgement of drainage corresponded in 79% of cases and differed 21% with proof of further not drained cavities only on CT. 4 bronchopleural fistulas were diagnosed by fluoroscopy, of which only 2 were evident on CT. Accompanying thoracic disease was reliably detected by CT only. Conclusions: Diagnosis of bronchopleural fistulas and judgement of the pleural drainage is best possible using fluoroscopy after application of contrast medium into the pleural space. CT is most accurate to detect further cavities that have not been drained, to look for concomitant thoracic disease, and to judge the morphology of the pleural cavity. Conventional radiography of the pleural space is effective and recommended to be used as a first line investigation for the follow-up of stage III empyemas. Patients in poor general condition (fever, elevated blood markers indicating inflammation) should be examined by both fluoroscopy and CT. (orig.) [de

  2. Factors controlling leaching of polycyclic aromatic hydrocarbons from petroleum source rock using nonionic surfactant

    Energy Technology Data Exchange (ETDEWEB)

    Akinlua, Akinsehinwa [Obafemi Awolowo Univ., Ile-Ife (Nigeria). Fossil Fuels and Environmental Geochemistry Group; Jochmann, Maik A.; Qian, Yuan; Schmidt, Torsten C. [Duisburg-Essen Univ., Essen (Germany). Instrumental Analytical Chemistry; Sulkowski, Martin [Duisburg-Essen Univ., Essen (Germany). Inst. of Environmental Analytical Chemistry

    2012-03-15

    The extraction of polycyclic aromatic hydrocarbons (PAHs) from petroleum source rock by nonionic surfactants with the assistance of microwave irradiation was investigated and the conditions for maximum yield were determined. The results showed that the extraction temperatures and type of surfactant have significant effects on extraction yields of PAHs. Factors such as surfactant concentration, irradiation power, sample/solvent ratio and mixing surfactants (i.e., mixture of surfactant at specific ratio) also influence the extraction efficiencies for these compounds. The optimum temperature for microwave-assisted nonionic surfactant extraction of PAHs from petroleum source rock was 120 C and the best suited surfactant was Brij 35. The new method showed extraction efficiencies comparable to those afforded by the Soxhlet extraction method, but a reduction of the extraction times and environmentally friendliness of the new nonionic surfactant extraction system are clear advantages. The results also show that microwave-assisted nonionic surfactant extraction is a good and efficient green analytical preparatory technique for geochemical evaluation of petroleum source rock. (orig.)

  3. Attenuation changes of the normal and ischemic canine kidney. Dynamic CT scanning after intravenous contrast medium bolus

    Energy Technology Data Exchange (ETDEWEB)

    Jaschke, W.; Lipton, M.J.; Boyd, D.P.; Cann, C.; Strauss, L.; Sievers, R.S.

    The potential of CT scanning to explore total and regional renal blood flow was evaluated in a dog model with unilateral renal artery stenosis (n=7, reduction of renal blood flow: 32-75% of base line flow). Attenuation versus time curves were generated for the renal cortex and medulla, as well as for the aorta and renal vein. A fast CT scanner was used which allowed for up to 24 scans/minute at the same level (slice thickness: 10 mm). A total of 10 ml contrast medim was injected into a peripheral vein for each scan series taken. During baseline conditions, the curve of the renal cortex and medulla demonstrated 2 peaks. The first peak was mainly related to early vascular enhancement, whereas the second peak corresponded mainly to the appearance of contrast medium in the distal convolutes and collecting ducts. Ischemia of the kidney resulted in a reduction of the first peak and a flattening of the leading edge slope. Transport of contrast medium through the extravascular compartments of the kidney was delayed during ischemia. Relative renal blood flow was obtained from the CT data by dividing peak enhancement by rise-time as assessed from the cortical curve. All measurements were related to baseline flow and validated by flow measurements using radioactive labeled microspheres (n=5). Correlation was found to be r=0.97. (orig.).

  4. Impact of non-ionic surfactant chemical structure on morphology and stability of polystyrene nanocomposite latex

    CSIR Research Space (South Africa)

    Greesh, N

    2016-01-01

    Full Text Available Polystyrene (PS) colloid particles in presence of non-ionic surfactant-modified clay particles were prepared by the free-radical polymerization of styrene monomers in emulsion. Three different types of non-ionic surfactants, sorbitan monopalmitate...

  5. Nanoparticles generated by laser in liquids as contrast medium and radiotherapy intensifiers

    Science.gov (United States)

    Restuccia, Nancy; Torrisi, Lorenzo

    2018-01-01

    The synthesis of Au and Ag nanoparticles (NP) though laser ablation in liquids as a function the laser parameters is presented. Spherical NPs with diameter distribution within 1 and 100 nm were prepared by laser ablation in water. The nanoparticles characterization was performed using optical spectroscopy and electronic microscopy (SEM and TEM) measurements. Studies of the possible use of metallic nanoparticles as intensifier of diagnostics imaging contrast medium and absorbing dose from ionizing radiations in traditional radiotherapy and protontherapy are presented. Examples of in vitro (in tissue equivalent materials) and in vivo (in mice), were conducted thank to simulation programs permitting to evaluate the enhancement of efficiency in imaging and therapy as a function of the NPs concentrations and irradiation conditions.

  6. Nanoparticles generated by laser in liquids as contrast medium and radiotherapy intensifiers

    Directory of Open Access Journals (Sweden)

    Restuccia Nancy

    2018-01-01

    Full Text Available The synthesis of Au and Ag nanoparticles (NP though laser ablation in liquids as a function the laser parameters is presented. Spherical NPs with diameter distribution within 1 and 100 nm were prepared by laser ablation in water. The nanoparticles characterization was performed using optical spectroscopy and electronic microscopy (SEM and TEM measurements. Studies of the possible use of metallic nanoparticles as intensifier of diagnostics imaging contrast medium and absorbing dose from ionizing radiations in traditional radiotherapy and protontherapy are presented. Examples of in vitro (in tissue equivalent materials and in vivo (in mice, were conducted thank to simulation programs permitting to evaluate the enhancement of efficiency in imaging and therapy as a function of the NPs concentrations and irradiation conditions.

  7. Case with high cervical intramedullary hemangioblastoma associated with arteriovenous fistula. CT with simultaneous intravenous and intrathecal injection of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takao; Shoji, Shin-ichi; Yanagisawa, Nobuo; Tada, Tsuyoshi; Kobayashi, Naoki

    1988-02-01

    A 34-year-old woman complained of right hemiparesis and pain in the right hand. Routine X-ray of the cervical portion failed to reveal abnormal findings. CT with intravenous contrast medium showed a large high-density mass in the spinal canal at the level of C2. Right vertebral angiography showed a hypervascular mass. With simultaneous intravenous and intrathecal injections of contrast medium, the tumor was shown as a moderately high-density area and the parenchyma of cord as a thin low-density area surrounding the tumor stain on CT. These CT appearances led to the final diagnosis of high cervical intramedullary hemangioblastoma associated with arteriovenous fistulae. Pathological findings are typical of hemangioblastoma. The usefulness of CT in detecting the localization of hypervascular spinal cord lesions is stressed. (Namekawa, K.).

  8. Contrast medium-induced nephropathy: Aspects on incidence ...

    African Journals Online (AJOL)

    Contrast media-induced nephropathy (CIN) is a well-known complication of radiological examinations employing iodine contrast media (I-CM). The rapid development and frequent use of coronary interventions and multi-channel detector computed tomography with concomitant administration of relatively large doses of ...

  9. Nonlinear image blending for dual-energy MDCT of the abdomen: can image quality be preserved if the contrast medium dose is reduced?

    Science.gov (United States)

    Mileto, Achille; Ramirez-Giraldo, Juan Carlos; Marin, Daniele; Alfaro-Cordoba, Marcela; Eusemann, Christian D; Scribano, Emanuele; Blandino, Alfredo; Mazziotti, Silvio; Ascenti, Giorgio

    2014-10-01

    The objective of this study was to compare the image quality of a dual-energy nonlinear image blending technique at reduced load of contrast medium with a simulated 120-kVp linear blending technique at a full dose during portal venous phase MDCT of the abdomen. Forty-five patients (25 men, 20 women; mean age, 65.6 ± 9.7 [SD] years; mean body weight, 74.9 ± 12.4 kg) underwent contrast-enhanced single-phase dual-energy CT of the abdomen by a random assignment to one of three different contrast medium (iomeprol 400) dose injection protocols: 1.3, 1.0, or 0.65 mL/kg of body weight. The contrast-to-noise ratio (CNR) and noise at the portal vein, liver, aorta, and kidney were compared among the different datasets using the ANOVA. Three readers qualitatively assessed all datasets in a blinded and independent fashion. Nonlinear blended images at a 25% reduced dose allowed a significant improvement in CNR (p < 0.05 for all comparisons), compared with simulated 120-kVp linear blended images at a full dose. No statistically significant difference existed in CNR and noise between the nonlinear blended images at a 50% reduced dose and the simulated 120-kVp linear blended images at a full dose. Nonlinear blended images at a 50% reduced dose were considered in all cases to have acceptable image quality. The dual-energy nonlinear image blending technique allows reducing the dose of contrast medium up to 50% during portal venous phase imaging of the abdomen while preserving image quality.

  10. Adverse side effects of metrizamide and iopamidolo in myelography

    International Nuclear Information System (INIS)

    Carella, A.; Di Cuonzo, F.; Vinjau, E.; Federico, F.; Lamberti, P.

    1982-01-01

    Nonionic water-soluble contrast medium, at first metrizamide and later Iopamidolo was used for lumbar myelography. Three serious neurological complications were noted: one case of total aphasia, one case of generalized seizures, and one of myoclonic jerking of the legs. (orig.)

  11. Patient radiation dose during fluoroscopy testes with contrast medium

    International Nuclear Information System (INIS)

    Darsalih, Abir Abdelrady El noor

    2016-09-01

    The purpose of this study was to assess the patient radiation dose received in fluoroscopy examinations during contrast medium. The cumulative air kerma (Ck), kerma area product (KAP) and fluoroscopy time were measured for sixty ( male and female ) patients undergoing five fluoroscopy examinations KAP metre which was installed for the purpose of this study. The mean kerma area product were found to be 2.681, 5.1561, 9.85529. 5.7974 and 13.09 Gy.cm"2 for HSG, A.S and D.S, GI Track and sonogram tests, respectively. The obtained mean cumulative dose was were 6.31, 13.88, 24.61, 22.56 and 32.14 mGy for HSG, A.S, A.S and D.S , GI Track, respectively, the mean fluoroscopy time were. 0.18, 0.51,0.89,1.57 and 1.75 min, for HSG, A.S, A.S, and D.S, G1 Track and sonogram test respectively. Patient dose is mainly dependent on the patient size, procedure, equipment used exposure factor and user experience. As KV and mA were controlled by the AEC and it was found to be well calibrated, possible optimization could be achieved by radiologist by decreasing the exposure time if possible. (Author)

  12. Contrast medium-enhanced MRI findings and changes over time in stage I tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Oztoprak, I. [Department of Radiology Cumhuriyet University Faculty of Medicine, 58140 Sivas (Turkey)], E-mail: oztoprak@cumhuriyet.edu.tr; Guemues, C.; Oztoprak, B. [Department of Radiology Cumhuriyet University Faculty of Medicine, 58140 Sivas (Turkey); Engin, A. [Department of Infectious Diseases, Cumhuriyet University Faculty of Medicine, Sivas (Turkey)

    2007-12-15

    Aim: To demonstrate the detailed imaging characteristics of early tuberculous meningitis (TBM) and changes over time on standard gadolinium-enhanced, T1-weighted magnetic resonance imaging (MRI) images. Materials and methods: Contrast-enhanced, T1-weighted, spin-echo MRI images of 26 patients with early TBM were evaluated retrospectively. Meningeal enhancement characteristics were categorized according to distribution and pattern as diffuse, focal, linear, nodular, and mixed. Results: We found that 35% of patients had diffuse meningeal enhancement and 65% of cases had focal meningeal enhancement. There was a predilection for focal meningeal enhancement in basal pial areas, the interpeduncular fossa being the most common. In six patients with diffuse meningeal enhancement admitted to hospital relatively early after the onset of symptoms, the type of meningeal enhancement later changed to the focal form. Conclusion: Reactive diffuse meningeal enhancement occurs in the early period of TBM on contrast medium-enhanced T1-weighted MR images, but later becomes limited to basal areas.

  13. Contrast medium-enhanced MRI findings and changes over time in stage I tuberculous meningitis

    International Nuclear Information System (INIS)

    Oztoprak, I.; Guemues, C.; Oztoprak, B.; Engin, A.

    2007-01-01

    Aim: To demonstrate the detailed imaging characteristics of early tuberculous meningitis (TBM) and changes over time on standard gadolinium-enhanced, T1-weighted magnetic resonance imaging (MRI) images. Materials and methods: Contrast-enhanced, T1-weighted, spin-echo MRI images of 26 patients with early TBM were evaluated retrospectively. Meningeal enhancement characteristics were categorized according to distribution and pattern as diffuse, focal, linear, nodular, and mixed. Results: We found that 35% of patients had diffuse meningeal enhancement and 65% of cases had focal meningeal enhancement. There was a predilection for focal meningeal enhancement in basal pial areas, the interpeduncular fossa being the most common. In six patients with diffuse meningeal enhancement admitted to hospital relatively early after the onset of symptoms, the type of meningeal enhancement later changed to the focal form. Conclusion: Reactive diffuse meningeal enhancement occurs in the early period of TBM on contrast medium-enhanced T1-weighted MR images, but later becomes limited to basal areas

  14. Delayed allergy-like reactions to X-ray contrast media. Second expert meeting

    International Nuclear Information System (INIS)

    Sviridov, N.K

    1998-01-01

    Materials of the second expert meeting of medical radiologists of USA, Germany, and Japan concerning delayed allergy-like reactions to X-ray contrast media (XRCM) are briefly considered. Attention is paid to the experimental and clinical data on the application of nonionic dimers, pathophysiological and immunological aspects of the reaction to XRCM, certain models and hypotheses, allergy to XRCM

  15. Medical uses non-ionizing radiation

    International Nuclear Information System (INIS)

    Ubeda Maeso, A.; Trillo Ruiz, M. A.

    2016-01-01

    This article reviews various clinical applications of non-ionizing radiation, focusing on the Hz-GHz frequency range. Depending on the signal characteristics, the applications cover several therapeutic areas, including osteology and traumatology, tissue regeneration, physiotherapy, chronic pain treatment, neurology, cardiology, urology and oncology. Electromagnetic therapies have proved simple, safe, low cost, devoid of side effects and able to treat the underlying pathology rather than simply alleviate the symptoms. Therefore, it is predictable that these therapies will have as serious impact on public health and associated costs. (Author)

  16. Effects of barium sulfate as a contrast medium to enterocutaneous fistulas

    International Nuclear Information System (INIS)

    Pelster, F.W.; Reichelt, S.; Arndt, M.; Eising, E.G.

    1989-01-01

    Fistulation following thoracic and epigastric interventions are conservatively treated, as a rule, because of the high rate of complications expected from reoperation. With properly functioning anastomotic transit, insufficiencies usually undergo spontaneous healing, within four to six weeks. Enterocutaneous fistulae developed in 29 of 271 patients with intrathoracic oesophagastric or oesophagojejunal anastomosis. Syringeal ramification into pleural or abdominal cavities were eliminated by means of an absorbable contrast medium, before barium sulphate was orally administered to all patients. Thoracic fistulae were closed after 21.8 days on average, while 20.3 days was the average period required for closure of epigastric fistulae. Barium sulphate was found to stimulate fistular tissue granulation, so that obliteration of the fistular system occurred much sooner, as compared to conservative treatment. The patient's quality of life can thus be improved, and hospitalisation can be shortened. Neither locally delimited nor systemic complications were observed in any of the cases described. (author)

  17. Use of non-ionizing electromagnetic fields for the treatment of cancer.

    Science.gov (United States)

    Jimenez, Hugo; Blackman, Carl; Lesser, Glenn; Debinski, Waldemar; Chan, Michael; Sharma, Sambad; Watabe, Kounosuke; Lo, Hui-Wen; Thomas, Alexandra; Godwin, Dwayne; Blackstock, William; Mudry, Albert; Posey, James; O'Connor, Rodney; Brezovich, Ivan; Bonin, Keith; Kim-Shapiro, Daniel; Barbault, Alexandre; Pasche, Boris

    2018-01-01

    Cancer treatment and treatment options are quite limited in circumstances such as when the tumor is inoperable, in brain cancers when the drugs cannot penetrate the blood-brain-barrier, or when there is no tumor-specific target for generation of effective therapeutic antibodies. Despite the fact that electromagnetic fields (EMF) in medicine have been used for therapeutic or diagnostic purposes, the use of non-ionizing EMF for cancer treatment is a new emerging concept. Here we summarize the history of EMF from the 1890's to the novel and new innovative methods that target and treat cancer by non-ionizing radiation.

  18. Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jia; Qu, Mingliang; Duan, Xinhui; Takahashi, Naoki; Kawashima, Akira; Leng, Shuai; McCollough, Cynthia H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2012-12-15

    To develop a dual-energy CT (DECT) method for differentiating uric acid (UA) from non-UA stones in the presence of iodinated contrast medium. Thirty UA and 45 non-UA stones were selected after infra-red spectroscopic analysis and independently placed in a 1.5-ml vial, which was filled first with saline and then with increasing concentrations of iodine. For each condition, tubes were put in a 35-cm water phantom and examined using a dual-source CT system at 100 and 140 kV. Virtual unenhanced images created from CT data sets of the stones in iodine-containing solutions provided position and volume information. This map was used to calculate a CT number ratio to differentiate stone type. A region-growing method was developed to improve the ability to differentiate between UA and non-UA stones with iodinated contrast medium. The sensitivity for detecting UA stones was 100 % for unenhanced images but fell to 18 % with 20 mgI/ml iodine solution and 0 % for higher concentrations. With region growing, the sensitivity for detecting UA stones was increased to 100 %, 82 %, 57 %, 50 % and 21 % for iodine solutions of 20, 40, 60, 80 and 100 mgI/ml. The region-growing method improves differentiation of UA from non-UA stones on contrast-enhanced DECT urograms. (orig.)

  19. Contrast-Enhanced Spectral Mammography: Comparison with Conventional Mammography and Histopathology in 152 Women

    OpenAIRE

    Luczyńska, Elzbieta; Heinze-Paluchowska, Sylwia; Dyczek, Sonia; Blecharz, Pawel; Rys, Janusz; Reinfuss, Marian

    2014-01-01

    Objective The goal of the study was to compare conventional mammography (MG) and contrast-enhanced spectral mammography (CESM) in preoperative women. Materials and Methods The study was approved by the local Ethics Committee and all participants provided informed consent. The study included 152 consecutive patients with 173 breast lesions diagnosed on MG or CESM. All MG examinations and consults were conducted in one oncology centre. Non-ionic contrast agent, at a total dose of 1.5 mL/kg body...

  20. Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chien-Ming; Chu, Sung-Yu; Hsu, Ming-Yi [Chang Gung University, Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital Linkou, College of Medicine, Taoyuan (China); Liao, Ying-Lan [National Tsing Hua University, Department of Biomedical Engineering and Environmental Sciences, Hsinchu (China); Tsai, Hui-Yu [Chang Gung University, Department of Medical Imaging and Radiological Sciences, College of Medicine, Taoyuan (China); Chang Gung University, Healthy Aging Research Center, Taoyuan (China); Chang Gung University, Department of Medical Imaging and Radiological Sciences, Taoyuan (China)

    2014-02-15

    To evaluate CT aortography at reduced tube voltage and contrast medium dose while maintaining image quality through iterative reconstruction (IR). The Institutional Review Board approved a prospective study of 48 patients who underwent follow-up CT aortography. We performed intra-individual comparisons of arterial phase images using 120 kVp (standard tube voltage) and 80 kVp (low tube voltage). Low-tube-voltage imaging was performed on a 320-detector CT with IR following injection of 40 ml of contrast medium. We assessed aortic attenuation, aortic attenuation gradient, image noise, contrast-to-noise ratio (CNR), volume CT dose index (CTDI{sub vol}), and figure of merit (FOM) of image noise and CNR. Two readers assessed images for diagnostic quality, image noise, and artefacts. The low-tube-voltage protocol showed 23-31 % higher mean aortic attenuation and image noise (both P < 0.01) than the standard-tube-voltage protocol, but no significant difference in the CNR and aortic attenuation gradients. The low-tube-voltage protocol showed a 48 % reduction in CTDI{sub vol} and an 80 % increase in FOM of CNR. Subjective diagnostic quality was similar for both protocols, but low-tube-voltage images showed greater image noise (P = 0.01). Application of IR to an 80-kVp CT aortography protocol allows radiation dose and contrast medium reduction without affecting image quality. (orig.)

  1. Nausea and vomiting after exposure to non-ionic contrast media: incidence and risk factors focusing on preparatory fasting.

    Science.gov (United States)

    Kim, Yeon Soo; Yoon, Soon Ho; Choi, Young Hun; Park, Chang Min; Lee, Whal; Goo, Jin Mo

    2018-04-25

    To prospectively evaluate the incidence of nausea and vomiting after exposure to non-ionic iodinated contrast media (ICM), and to identify potential risk factors, with a focus on fasting duration for solid food and fluids, separately. From January to March 2017, 1175 patients (605 males, 570 females; median age, 60 years; range, 20-91 years) undergoing ICM-enhanced CT were included in this study. Patients received instructions for a 6 h preparatory fast from solid food. Nausea and vomiting after ICM exposure were assessed on a 3-point scale (mild, moderate, severe). Patients' characteristics and the fasting duration were evaluated to identify risk factors using logistic regression analysis. Of the 1175 patients, 34 (2.9%; 95% CI, 2.0-4.0%) experienced mild nausea. No patients experienced vomiting (95% CI, 0.0000-0.0005%). 1173 (99.8%) carried out a 6 h fast, and the median fasting durations were 14 h for solid food (IQR, 12.5-15.5 h) and 11 h for fluid (IQR, 0-13.5 h), respectively. Fasting durations for solid food and fluids were not associated with nausea on uni-variate regression analyses (p = 0.282-1.000 andP=0.146-1.000, respectively). Multi-variate regression analysis revealed that a history of drug hypersensitivity (OR = 4.33; 95% CI, 1.85-17.52; p = .039) was independent risk factors for nausea, whereas iobitridol was less nauseous (OR = 0.32; 95% CI, 0.11-0.90; p = .032). Mild nausea occurred in 2.9% of patients and none vomited in our study population with a 6 h preparatory fast from solid food. Many patients underwent excessive fasting for fluids as well as solid food and their fasting durations were not associated with nausea. Advances in knowledge: We firstly evaluated fasting durations for solid food and fluids, and their impacts on vomiting or nausea after ICM exposure with an instruction of 6 h preparatory fast for solid food: many patients underwent excessive fasting for fluids and the fasting duration was unrelated to

  2. Triblock Copolymers with Grafted Fluorine-Free Amphiphilic Non-Ionic Side Chains for Antifouling and Fouling-Release Applications

    Energy Technology Data Exchange (ETDEWEB)

    Y Cho; H Sundaram; C Weinman; M Paik; M Dimitriou; J Finlay; M Callow; J Callow; E Kramer; C Ober

    2011-12-31

    Fluorine-free, amphiphilic, nonionic surface active block copolymers (SABCs) were synthesized through chemical modification of a polystyrene-block-poly(ethylene-ran-butylene)-block-polyisoprene triblock copolymer precursor with selected amphiphilic nonionic Brij and other surfactants. Amphiphilicity was imparted by a hydrophobic aliphatic group combined with a hydrophilic poly(ethylene glycol) (PEG) group-containing moiety. The surfaces were characterized by dynamic water contact angle, atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and near edge X-ray absorption fine structure (NEXAFS) analysis. In biofouling assays, settlement (attachment) of both spores of the green alga Ulva and cells of the diatom Navicula on SABCs modified with Brij nonionic side chains was significantly reduced relative to a PDMS standard, with a nonionic surfactant combining a PEG group and an aliphatic moiety demonstrating the best performance. Additionally, a fouling-release assay using sporelings (young plants) of Ulva and Navicula suggested that the SABC derived from nonionic Brij side chains also out-performed PDMS as a fouling-release material. Good antifouling and fouling-release properties were not demonstrated for the other two amphiphilic surfaces derived from silicone and aromatic group containing nonionic surfactants included in this study. The results suggest that small differences in chemical surface functionality impart more significant changes with respect to the antifouling settlement and fouling-release performance of materials than overall wettability behavior.

  3. Nanotoxic Profiling of Novel Iron Oxide Nanoparticles Functionalized with Perchloric Acid and SiPEG as a Radiographic Contrast Medium

    Directory of Open Access Journals (Sweden)

    Muhamad Idham Mohamed

    2015-01-01

    Full Text Available Emerging syntheses and findings of new metallic nanoparticles (MNPs have become an important aspect in various fields including diagnostic imaging. To date, iodine has been utilized as a radiographic contrast medium. However, the raise concern of iodine threats on iodine-intolerance patient has led to search of new contrast media with lower toxic level. In this animal modeling study, 14 nm iron oxide nanoparticles (IONPs with silane-polyethylene glycol (SiPEG and perchloric acid have been assessed for toxicity level as compared to conventional iodine. The nanotoxicity of IONPs was evaluated in liver biochemistry, reactive oxygen species production (ROS, lipid peroxidation mechanism, and ultrastructural evaluation using transmission electron microscope (TEM. The hematological analysis and liver function test (LFT revealed that most of the liver enzymes were significantly higher in iodine-administered group as compared to those in normal and IONPs groups P<0.05. ROS production assay and lipid peroxidation indicator, malondialdehyde (MDA, also showed significant reductions in comparison with iodine group P<0.05. TEM evaluation yielded the aberration of nucleus structure of iodine-administered group as compared to those in control and IONPs groups. This study has demonstrated the less toxic properties of IONPs and it may postulate that IONPs are safe to be applied as radiographic contrast medium.

  4. Role of hemolysis in potassium release by iodinated contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hayakawa, K.; Nakamura, T.; Shimizu, Y. [Department of Radiology, Kyoto City Hospital (Japan)

    1999-09-01

    It has been demonstrated that an iodinated contrast medium (CM) causes release of potassium into blood vessel lumina, resulting in an increase in serum potassium. The purpose of the present study was to assess whether this potassium release is due to hemolysis. Fresh human blood was mixed in vitro with CM at a ratio of 10:2. Potassium release rates were determined, and serum haptoglobin and free hemoglobin were measured after 30 min of exposure to CM. To compare the potassium release curve between CM exposure and true hemolysis induced by distilled water, fresh human blood was also mixed with distilled water. The level of serum haptoglobin decreased due to hemodilution. Changes in haptoglobin were not correlated with potassium release rates. The serum free hemoglobin level did not increase significantly, and there was no correlation between changes in the free hemoglobin level and the rate of potassium release. Hemolysis caused by water occurred instantaneously, whereas potassium release caused by CM was a slow response, which was linearly correlated with exposure time. Potassium release from blood cannot be explained by hemolysis. (orig.) With 4 figs., 4 tabs., 3 refs.

  5. Intravenous contrast medium application in elderly patients - evaluation of Iopentol (Imagopaque trademark 300); Intravenoese Kontrastmittel-Applikation bei aelteren Patienten - Anwendungsbeobachtung von Iopentol (Imagopaque trademark 300)

    Energy Technology Data Exchange (ETDEWEB)

    Rathsmann, P.; Jacobs, G.F.; Mueller, R.D. [Zentrum fuer Klinische Radiologie, Kliniken Essen-Sued (Germany)

    2004-12-01

    Purpose: We examined the subjective compatibility of elderly patients who received the intravenous contrast medium Iopentol (Imagopaque trademark 300). In addition, objective data were acquired to show possible interactions between contrast media and organ systems in old patients. Methods and materials: A CT scan with intravenous application of contrast media was performed on 132 patients ranging in age from 75 to 96 years. The patients were questioned about their individual sensations. In addition, blood pressure, creatinine and CT-densitometry were acquired as objective date. Results: The patients' individual sensations and clinical data show a very low rate of complications. Mild allergic reactions were noticed in two patients. No severe anaphylactic reactions were encountered. Statistically significant changes in blood pressure before and after administration of the contrast medium were not observed. The serum creatinine concentration was unchanged after application of contrast media. For CT-densitometry, the patients were divided into two groups, one group with patients 75-84 years and the other group with patients 85-96 years of age. CT-densitometry showed no age-related differences. The protocol of contrast administration resulted in excellent opacification of the examined regions, only the liver did not enhance in some cases before the opacification of the portal vein. Conclusion: It is shown that old age alone is no reason to withhold contrast media containing iodine when performing CT. For the evaluation of the liver, however, the peculiarities of old age have to be taken into account and the interval between injection of the contrast medium and beginning of the spiral-CT has to be extended. (orig.)

  6. Studies on the usefulness of negative contrast medium for CT-fatty emulsion-in diseases of the gastrointestinal tract

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Tsuneo; Kameda, Kyoko; Tanaka, Koji; Nishimura, Shigeru; Higashide, Toshiaki [Osaka Police Hospital (Japan)

    1983-09-01

    Investigation was made on the usefulness of negative contrast medium for CT-fatty emulsion-, which is applicable to the whole area of the gastrointestinal tract, in diagnoses of diseases of the stomach, pancreas, colon and the organs adjacent to the three. After the administration of the drug, CT was performed and the thickness of the walls were measured for the normal upper gastrointestinal tract in 50 patients and for the normal colon in 25. The normal gastric walls did not exceed 5 mm and the walls of the colon measured about 2.1 mm. Gastric tumors were projected at 80.4%. Especially, the drug was useful for the early diagnosis of schirrus. The pancreas was more clearly projected in 88.4% of the patients. The reconstruction method using the present drug was useful for the investigation of the relationship between the two organs, the stomach and the duodenum, and the pancreas. When CT was performed on a patient laying this right side on the bed, invasion of pancreatic cancer and gastric antrum cancer into the circumferntial organs could be diagnosed. The drug was useful for the identification of tumors in the colon and intrapelvic lesions. The medium was also given to four patients with colitis ulcerosa and the obtained findings on the wall features were same as those obtained by barium enema. The present drug was little associated with side effects and is considered to be an excellent negative contrast medium for all the gastrointestinal tracts.

  7. Does MRI with oral contrast medium allow single-study depiction of inflammatory bowel disease enteritis and colitis?

    International Nuclear Information System (INIS)

    Cronin, Carmel G.; Lohan, Derek G.; Browne, Ann Michelle; Roche, Clare; Murphy, Joseph M.

    2010-01-01

    To assess the feasibility and utility of magnetic resonance (MR) imaging of the bowel in concurrent small- and large-bowel evaluation for the presence of inflammatory bowel disease (IBD). Over a 5-year period, 62 MR examinations performed on 53 patients demonstrated evidence of IBD. Sixteen of these 53 (30.1%) patients had imaging findings of colonic disease and underwent 19 formal MR small bowel examinations. These were further evaluated for bowel distention and image quality. The sensitivity and specificity of the technique compared with colonoscopy as the 'gold standard' was evaluated. Simultaneous imaging of the colon is feasible at MR small bowel follow-through with moderate-to-excellent colonic visibility and colon distention obtained when the contrast medium is present in the colon at the time of image acquisition. MR imaging had a sensitivity of 80% (0.56-0.93), specificity of 100% (0.77-1.00), positive predictive value (PPV) of 1 and a negative predictive value (NPV) of 0.8 for the identification of colitis (based on available concurrent correlation of 38/62 examinations with colonoscopy). Small and large bowel MR imaging with orally consumed contrast medium represents a promising, feasible, non-invasive, non-radiating single mode of assessment of the entire gastrointestinal tract, performed at a single sitting. (orig.)

  8. In vitro experiments for the development of a high density (HD) barium sulfate contrast medium

    International Nuclear Information System (INIS)

    Klein, J.

    1986-01-01

    In vitro experiments with the high-density (HD) barium meal Falibaryt HD are described. Several charges of BaSO 4 were tested together with certain additives influencing dispersion, stability of the suspension, flowability, surface tension etc. Particle size spectra were measured by the manufacturer, VEB Fahlberg-List. With a simple PVC test plate containing several grooves simulating small details (areae gastricae) the diagnostic capabilities of the HD contrast medium were evaluated in an in vitro test. The developed barium meal Falibaryt HD is in its physical and chemical parameters comparable with Prontobario-HD, one of the best HD barium meals. (author)

  9. Phase Behaviour Study of Swiftlet Nest Using Virgin Coconut Oil with Non-Ionic Surfactants

    International Nuclear Information System (INIS)

    Siti Salwa Abd Gani; Siti Zulaika Adisah; Siti Salwa Abd Gani

    2015-01-01

    Virgin coconut oil (VCO) is the oil that obtained from fresh and mature kernel of the coconut by mechanical or natural means with or without the application of heat, which does not lead to alteration of the nature of the oil. It have advantages such as strengthens the immune system because of its lauric acid content. It also has medium-chain fatty acids which heighten metabolism and energy, thus stimulating the thyroid. Swiftlet nest as an active ingredient need to be dispersed in a carrier system. Thus, ternary phase diagrams were constructed to find the suitable and stable system for it. The phase behavior of systems has been investigated by constructing ternary phase diagrams consisting of non-ionic surfactants/VCO:bird nest/water. The surfactants used were Sorbitan tri-oleate (Span 85), Sorbitan mono-oleate (Span 80), Sorbitan monolaurate (Span 20), Polyoxyethylene(20) sorbitan tri-oleate (Tween 85) and Polyoxyethylene (20) sorbitan mono-oleate (Tween 80). These systems include several phase regions such as homogeneous, isotropic, two-phase and three-phase regions. Different hydrophilic lipophilic balance (HLB) value of non-ionic surfactants exhibit different ternary diagram characteristics. A lower HLB shows a more oil-soluble and a more water-soluble surfactant (larger homogeneous and isotropic region in ternary phase diagrams) whereas high value of HLB shows the reverse of that result. The results show that the T85/VCO:bird nest/water system gave better performance than the other four individual surfactant systems. As a conclusion, high hydrophilic lipophilic balance (HLB) values of surfactant were found to be a good surfactant for the formulation of VCO:bird nest emulsion for cosmetic and pharmaceutical purposes. (author)

  10. Body surface area adapted iopromide 300 mg/ml versus 370 mg/ml contrast medium injection protocol: Influence on quantitative and clinical assessment in combined PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Verburg, Frederik A., E-mail: fverburg@ukaachen.de [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Apitzsch, Jonas [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Lensing, Carina [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Kuhl, Christiane K. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Pietsch, Hubertus [Bayer Pharma AG, Müllerstrasse 178, 13353 Berlin (Germany); Mottaghy, Felix M. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Behrendt, Florian F. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany)

    2013-12-01

    Purpose: To investigate the quantitative and qualitative differences between combined positron emission tomography and computed X-ray tomography (PET/CT) enhanced with contrast medium with either an iodine concentration 300 mg/ml or 370 mg/ml. Materials and methods: 120 consecutive patients scheduled for F-18-Fluorodeoxyglucose (FDG) PET/CT were included. The first (second) 60 patients received contrast medium with 300 (370) mg iodine/ml. Intravenous injection protocols were adapted for an identical iodine delivery rate (1.3 mg/s) and body surface area (BSA) adapted iodine dose (22.26 g I/m{sup 2}). Maximum and mean standardized uptake values (SUV{sub max}; SUV{sub mean}) and contrast enhancement (HU) were determined in the ascending aorta, the abdominal aorta, the inferior vena cava, the portal vein, the liver and the right kidney in the venous contrast medium phase. PET data were evaluated visually for the presence of malignancy and image quality. Results: Both media caused significantly higher values for HU, SUV{sub mean} and SUV{sub max} for the enhanced PET/CT than the non-enhanced one (all p < 0.01). There were no significant differences in the degree of increase of HU, SUV{sub mean} and SUV{sub max} between the two contrast media at any anatomic site (all p > 0.05). Visual evaluation of lesions showed no differences between contrast and non-contrast PET/CT or between the two different contrast media (p = 0.77). Conclusion: When using a constant iodine delivery rate and total iodine dose in a BSA adapted injection protocol, there are no quantitative or qualitative differences in either CT or PET between contrast media with an iodine concentration of 300 mg/ml and 370 mg/ml, respectively.

  11. Nonionic surfactant Brij35 effects on toluene biodegradation in a ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-10-19

    Oct 19, 2009 ... Nonionic surfactants are usually used in the bioavailability studies due to their rela- ..... Leson G, Winer AM (1991) Biofiltration: an innovative air pollution control technology for ... thermodynamics and kinetics. Lewis publishers ...

  12. Immunologic basis for adverse reactions to radiographic contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Stejskal, V; Nilsson, R; Grepe, A [Astra Pharmaceuticals AB, Soedertaelje (Sweden). Lab. of Safety Assessment Stockholm Univ. (Sweden). Dept. of Genetic and Cellular Toxicology Stockholm Univ. (Sweden). Wallenberglaboratoriet Danderyds Sjukhus, Danderyd (Sweden). Radiologic Clinic

    1990-11-01

    The lymphocyte transformation test (LTT) was used to elucidate whether certain side effects induced by radiographic contrast media have an immunologic etiology. Groups studied were: 8 patients who had previously experienced adverse reactions in association with urography, 6 patients who underwent urography without notable side reactions, 17 occupationally exposed nurses, and 9 unexposed controls. The lymphocytes from 2 hypersensitive patients and from 11 nurses exhibited a positive proliferative response to amidotrizoate. Five nurses who had shown a positive response, had a previous history of hypersensitivity reactions when handling contrast media, whereas the remaining 6 were free of symptoms. Amidotrizoatespecific memory cells were absent in patients who underwent urography without signs of hypersensitivity and in 7/9 of unexposed control subjects. Lymphocytes from patients sensitive to amidotrizoate cross-reacted to structurally related ionic contrast media while nonionic contrast agents did not induce proliferation of the lymphocytes. Thus, ionic radiographic contrast agents have antigenic properties in man. Irradiated mixtures of radiographic contrast media and serum proteins were, in general, not effective in inducing an LTT response. (orig.).

  13. Immunologic basis for adverse reactions to radiographic contrast media

    International Nuclear Information System (INIS)

    Stejskal, V.; Nilsson, R.; Grepe, A.; Stockholm Univ.; Stockholm Univ.; Danderyds Sjukhus, Danderyd

    1990-01-01

    The lymphocyte transformation test (LTT) was used to elucidate whether certain side effects induced by radiographic contrast media have an immunologic etiology. Groups studied were: 8 patients who had previously experienced adverse reactions in association with urography, 6 patients who underwent urography without notable side reactions, 17 occupationally exposed nurses, and 9 unexposed controls. The lymphocytes from 2 hypersensitive patients and from 11 nurses exhibited a positive proliferative response to amidotrizoate. Five nurses who had shown a positive response, had a previous history of hypersensitivity reactions when handling contrast media, whereas the remaining 6 were free of symptoms. Amidotrizoatespecific memory cells were absent in patients who underwent urography without signs of hypersensitivity and in 7/9 of unexposed control subjects. Lymphocytes from patients sensitive to amidotrizoate cross-reacted to structurally related ionic contrast media while nonionic contrast agents did not induce proliferation of the lymphocytes. Thus, ionic radiographic contrast agents have antigenic properties in man. Irradiated mixtures of radiographic contrast media and serum proteins were, in general, not effective in inducing an LTT response. (orig.)

  14. Impact of Surface Active Ionic Liquids on the Cloud Points of Nonionic Surfactants and the Formation of Aqueous Micellar Two-Phase Systems.

    Science.gov (United States)

    Vicente, Filipa A; Cardoso, Inês S; Sintra, Tânia E; Lemus, Jesus; Marques, Eduardo F; Ventura, Sónia P M; Coutinho, João A P

    2017-09-21

    Aqueous micellar two-phase systems (AMTPS) hold a large potential for cloud point extraction of biomolecules but are yet poorly studied and characterized, with few phase diagrams reported for these systems, hence limiting their use in extraction processes. This work reports a systematic investigation of the effect of different surface-active ionic liquids (SAILs)-covering a wide range of molecular properties-upon the clouding behavior of three nonionic Tergitol surfactants. Two different effects of the SAILs on the cloud points and mixed micelle size have been observed: ILs with a more hydrophilic character and lower critical packing parameter (CPP formation of smaller micelles and concomitantly increase the cloud points; in contrast, ILs with a more hydrophobic character and higher CPP (CPP ≥ 1) induce significant micellar growth and a decrease in the cloud points. The latter effect is particularly interesting and unusual for it was accepted that cloud point reduction is only induced by inorganic salts. The effects of nonionic surfactant concentration, SAIL concentration, pH, and micelle ζ potential are also studied and rationalized.

  15. Comet assay as a procedure for detecting possible genotoxicity induced by non-ionizing radiation

    OpenAIRE

    Zsuzsanna Nemeth

    2015-01-01

    Non-ionizing radiation (NIR) is the term given to radiation in the part of the electromagnetic spectrum that does not have enough energy to ionize atoms or molecules directly. The NIR includes electric and magnetic fields up to 300 GHz, infrared, visible, and ultraviolet radiation (UV). People are exposed to non-ionizing radiation by several man-made sources every day. From highest to lowest energy, this includes for example microwave ovens, cell phones, baby monitors, cordless phones, ga...

  16. Dry preparation for virtual CT colonography with fecal tagging using water-soluble contrast medium: initial results

    International Nuclear Information System (INIS)

    Bielen, Didier; Thomeer, Maarten; Vanbeckevoort, Dirk; Marchal, Guy; Kiss, Gabriel; Maes, Frederik; Rutgeerts, Paul

    2003-01-01

    The purpose of this study was to evaluate the feasibility of a dry bowel preparation, i.e. without laxative fluids, for virtual CT colonography (VCTC), and its impact on patient acceptance compared with conventional colonoscopy (CC). A randomly chosen patient population scheduled for CC (n=11) was first submitted to VCTC after a dry preparation, consisting of low-residue meals combined with a small amount of a iodinated water-soluble contrast medium during each meal 3 days before VCTC. In different colon segments and between different persons, the degree of tagging in VCTC was evaluated and graded. Patient acceptance and future preference were assessed for both preparations as well as for both investigations. The mixing of the contrast with the intestinal content results in contrast impregnated stool, the tagged feces. The degree of fecal tagging was good in the majority of the patients and the colonic segments, especially in the descending colon and sigmoid. Furthermore, patient acceptance and preference were clearly in favour of VCTC compared with CC merely because of the non-invasiveness of the dry preparation. Dry bowel preparation and VCTC is a promising approach towards a patient-friendly colon cancer-screening setup. (orig.)

  17. Experimental Studies for the Evaluation of Non-Ionizing Radiation Levels

    International Nuclear Information System (INIS)

    Nasr, A.; Ashour, M.

    2008-01-01

    This article concerns the characteristic studies of non-ionizing; microwave, radiations. The power density levels, frequency ranges, modulation types, and the Fast Fourier Transform (FFT) are discussed. The experimental data are collected from the Egyptian Atomic Energy Authority (EAEA) locations in Nasr city and Anshas. This study has been carried out by Spectrum analyzer (SA) system, which implied radio frequency coaxial cable and horn antenna with height holders. The horn antenna was adjusted to scan all directions for investigating the signal strength. From this study, we obtain two main non-ionizing signals at center frequencies 900, and 1800 MHz, which are exploited by mobile communications networks. During the silence state, the measured maximum power densities levels for both frequencies are 0.553 μ W/cm 2 and 0.0191μW/cm 2 , respectively. While the measured maximum power densities, during alarm (ringing) state, are 98.67μ W/cm 2 and 2.961μ W/cm 2 for considered two frequencies, correspondingly. One can notice that the power densities are multiplied 178 times and 155 times for the same mentioned frequencies in that order. Moreover, these non-ionizing signals are analyzed theoretically and experimentally by utilizing FFT functions to clarify the Amplitude Modulations (AM) ratios and voltage strengths of these signals. Furthermore, the Occupied Band Width (OBW) ratio, and the division from the center frequency of the channel, (δFc) are clarified

  18. Nonthermal effects in thermal treatment applications of nonionizing irradiation

    Science.gov (United States)

    Thomsen, Sharon

    2005-04-01

    Several non-thermal factors influence the primary and secondary effects of interstitial thermal treatments using various types of non-ionizing irradiation. Recognition and understanding of the influences of these various factors are important in choice of energy source, the configuration of the application instrument and the design of treatments.

  19. Exposure to electromagnetic fields (non-ionizing radiation) and its relationship with childhood leukemia: A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Calvente, I.; Fernandez, M.F. [Laboratory of Medical Investigations, San Cecilio University Hospital, CIBER de Epidemiologia y Salud Publica (CIBERESP) (Spain); Department of Radiology, University of Granada, Granada (Spain); Villalba, J. [Department of Radiology, University of Granada, Granada (Spain); Olea, N. [Laboratory of Medical Investigations, San Cecilio University Hospital, CIBER de Epidemiologia y Salud Publica (CIBERESP) (Spain); Department of Radiology, University of Granada, Granada (Spain); Nunez, M.I., E-mail: isabeln@ugr.es [Department of Radiology, University of Granada, Granada (Spain)

    2010-07-15

    Childhood exposure to physical contamination, including non-ionizing radiation, has been implicated in numerous diseases, raising concerns about the widespread and increasing sources of exposure to this type of radiation. The primary objective of this review was to analyze the current state of knowledge on the association between environmental exposure to non-ionizing radiation and the risk of childhood leukemia. Scientific publications between 1979 and 2008 that include examination of this association have been reviewed using the MEDLINE/PubMed database. Studies to date have not convincingly confirmed or ruled out an association between non-ionizing radiation and the risk of childhood leukemia. Discrepancies among the conclusions of the studies may also be influenced by confounding factors, selection bias, and misclassification. Childhood defects can result from genetic or epigenetic damage and from effects on the embryo or fetus, which may both be related to environmental exposure of the parent before conception or during the pregnancy. It is therefore critical for researchers to define a priori the type and 'window' of exposure to be assessed. Methodological problems to be solved include the proper diagnostic classification of individuals and the estimated exposure to non-ionizing radiation, which may act through various mechanisms of action. There appears to be an urgent need to reconsider exposure limits for low frequency and static magnetic fields, based on combined experimental and epidemiological research into the relationship between exposure to non-ionizing radiation and adverse human health effects.

  20. Exposure to electromagnetic fields (non-ionizing radiation) and its relationship with childhood leukemia: a systematic review.

    Science.gov (United States)

    Calvente, I; Fernandez, M F; Villalba, J; Olea, N; Nuñez, M I

    2010-07-15

    Childhood exposure to physical contamination, including non-ionizing radiation, has been implicated in numerous diseases, raising concerns about the widespread and increasing sources of exposure to this type of radiation. The primary objective of this review was to analyze the current state of knowledge on the association between environmental exposure to non-ionizing radiation and the risk of childhood leukemia. Scientific publications between 1979 and 2008 that include examination of this association have been reviewed using the MEDLINE/PubMed database. Studies to date have not convincingly confirmed or ruled out an association between non-ionizing radiation and the risk of childhood leukemia. Discrepancies among the conclusions of the studies may also be influenced by confounding factors, selection bias, and misclassification. Childhood defects can result from genetic or epigenetic damage and from effects on the embryo or fetus, which may both be related to environmental exposure of the parent before conception or during the pregnancy. It is therefore critical for researchers to define a priori the type and "window" of exposure to be assessed. Methodological problems to be solved include the proper diagnostic classification of individuals and the estimated exposure to non-ionizing radiation, which may act through various mechanisms of action. There appears to be an urgent need to reconsider exposure limits for low frequency and static magnetic fields, based on combined experimental and epidemiological research into the relationship between exposure to non-ionizing radiation and adverse human health effects.

  1. Exposure to electromagnetic fields (non-ionizing radiation) and its relationship with childhood leukemia: A systematic review

    International Nuclear Information System (INIS)

    Calvente, I.; Fernandez, M.F.; Villalba, J.; Olea, N.; Nunez, M.I.

    2010-01-01

    Childhood exposure to physical contamination, including non-ionizing radiation, has been implicated in numerous diseases, raising concerns about the widespread and increasing sources of exposure to this type of radiation. The primary objective of this review was to analyze the current state of knowledge on the association between environmental exposure to non-ionizing radiation and the risk of childhood leukemia. Scientific publications between 1979 and 2008 that include examination of this association have been reviewed using the MEDLINE/PubMed database. Studies to date have not convincingly confirmed or ruled out an association between non-ionizing radiation and the risk of childhood leukemia. Discrepancies among the conclusions of the studies may also be influenced by confounding factors, selection bias, and misclassification. Childhood defects can result from genetic or epigenetic damage and from effects on the embryo or fetus, which may both be related to environmental exposure of the parent before conception or during the pregnancy. It is therefore critical for researchers to define a priori the type and 'window' of exposure to be assessed. Methodological problems to be solved include the proper diagnostic classification of individuals and the estimated exposure to non-ionizing radiation, which may act through various mechanisms of action. There appears to be an urgent need to reconsider exposure limits for low frequency and static magnetic fields, based on combined experimental and epidemiological research into the relationship between exposure to non-ionizing radiation and adverse human health effects.

  2. Phase equilibria for mixtures containing nonionic surfactant systems: Modeling and experiments

    International Nuclear Information System (INIS)

    Shin, Moon Sam; Kim, Hwayong

    2008-01-01

    Surfactants are important materials with numerous applications in the cosmetic, pharmaceutical, and food industries due to inter-associating and intra-associating bond. We present a lattice fluid equation-of-state that combines the quasi-chemical nonrandom lattice fluid model with Veytsman statistics for (intra + inter) molecular association to calculate phase behavior for mixtures containing nonionic surfactants. We also measured binary (vapor + liquid) equilibrium data for {2-butoxyethanol (C 4 E 1 ) + n-hexane} and {2-butoxyethanol (C 4 E 1 ) + n-heptane} systems at temperatures ranging from (303.15 to 323.15) K. A static apparatus was used in this study. The presented equation-of-state correlated well with the measured and published data for mixtures containing nonionic surfactant systems

  3. The Application of Contrast Media for In Vivo Feature Enhancement in X-Ray Computed Tomography of Soil-Grown Plant Roots.

    Science.gov (United States)

    Keyes, Samuel D; Gostling, Neil J; Cheung, Jessica H; Roose, Tiina; Sinclair, Ian; Marchant, Alan

    2017-06-01

    The use of in vivo X-ray microcomputed tomography (μCT) to study plant root systems has become routine, but is often hampered by poor contrast between roots, soil, soil water, and soil organic matter. In clinical radiology, imaging of poorly contrasting regions is frequently aided by the use of radio-opaque contrast media. In this study, we present evidence for the utility of iodinated contrast media (ICM) in the study of plant root systems using μCT. Different dilutions of an ionic and nonionic ICM (Gastrografin 370 and Niopam 300) were perfused into the aerial vasculature of juvenile pea plants via a leaf flap (Pisum sativum). The root systems were imaged via μCT, and a variety of image-processing approaches used to quantify and compare the magnitude of the contrast enhancement between different regions. Though the treatment did not appear to significantly aid extraction of full root system architectures from the surrounding soil, it did allow the xylem and phloem units of seminal roots and the vascular morphology within rhizobial nodules to be clearly visualized. The nonionic, low-osmolality contrast agent Niopam appeared to be well tolerated by the plant, whereas Gastrografin showed evidence of toxicity. In summary, the use of iodine-based contrast media allows usually poorly contrasting root structures to be visualized nondestructively using X-ray μCT. In particular, the vascular structures of roots and rhizobial nodules can be clearly visualized in situ.

  4. Adverse drug reactions to CT contrast media in south Korea: Incidence and risk factors

    International Nuclear Information System (INIS)

    Bae, Kyung Soo; Jeon, Kyung Nyeo; Moon, Jin Il; Choi, Bo Hwa; Baek, Hye Jin; Cho, Soo Buem; Lee, Sang Min; Ha, Ji Young; Choi, Dae Seob; Cho, Jae Min; Na, Jae Beom

    2016-01-01

    To evaluate the incidence, severity, and risk factors of adverse drug reactions (ADR) to intravenous administration of nonionic iodinated contrast media in computed tomography (CT), and to determine the recurrence rate after premedication in patients with a previous history of ADR. We prospectively recorded all ADR to intravenous CT contrast media in 32313 consecutive outpatients (54572 cases) who underwent contrast enhanced CT examinations. Clinical report forms and electronic medical records were reviewed to search for the incidence of ADR, treatment, and clinical outcome of patients. The risk factors of ADR to CT contrast media (age, sex, history of previous ADR, season) were evaluated using statistical analysis. Of the 54572 cases, a total of 191 (0.35%) had adverse reactions. Of the 191 cases, 157 (82%) were categorized as mild reactions, 29 (15%) were moderate, and 5 (3%) were severe. A total of 165 (86.4%) cases had acute adverse reactions (which occurred within 1 hour after administration), while 26 (13.6%) had delayed adverse reactions (occurred 1 hour after the administration). The rate of ADR was significantly higher in females [relative risk (RR) = 2.05, 95% confidence interval (CI) 1.53-2.75], patients under the age of 60 years (RR = 1.45, 95% CI 1.07-1.98), patients with a history of previous ADR (RR = 6.51, 95% CI 3.13-13.57), and in the spring season (RR = 1.44, 95% CI 1.07-1.95). The recurrence rate after premedication in patients with previous ADR to CT contrast media was 3.2% (8/247). No deaths occurred that were attributed to the contrast media. The incidence of ADR to nonionic CT contrast media was 0.35%; most of which were mild reactions. Risk factors for ADR included female gender, an age of under 60 years, a history of previous ADR, and spring season

  5. Adverse drug reactions to CT contrast media in south Korea: Incidence and risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Kyung Soo; Jeon, Kyung Nyeo; Moon, Jin Il; Choi, Bo Hwa; Baek, Hye Jin; Cho, Soo Buem [Dept. of Radiology, Gyeongsang National University Changwon Hospital, Gyeongsang National University School of Medicine, Changwon (Korea, Republic of); Lee, Sang Min; Ha, Ji Young; Choi, Dae Seob; Cho, Jae Min; Na, Jae Beom [Dept. of Radiology, Gyeongsang National University Hospital, Gyeongsang National University School of Medicine, Jinju (Korea, Republic of)

    2016-07-15

    To evaluate the incidence, severity, and risk factors of adverse drug reactions (ADR) to intravenous administration of nonionic iodinated contrast media in computed tomography (CT), and to determine the recurrence rate after premedication in patients with a previous history of ADR. We prospectively recorded all ADR to intravenous CT contrast media in 32313 consecutive outpatients (54572 cases) who underwent contrast enhanced CT examinations. Clinical report forms and electronic medical records were reviewed to search for the incidence of ADR, treatment, and clinical outcome of patients. The risk factors of ADR to CT contrast media (age, sex, history of previous ADR, season) were evaluated using statistical analysis. Of the 54572 cases, a total of 191 (0.35%) had adverse reactions. Of the 191 cases, 157 (82%) were categorized as mild reactions, 29 (15%) were moderate, and 5 (3%) were severe. A total of 165 (86.4%) cases had acute adverse reactions (which occurred within 1 hour after administration), while 26 (13.6%) had delayed adverse reactions (occurred 1 hour after the administration). The rate of ADR was significantly higher in females [relative risk (RR) = 2.05, 95% confidence interval (CI) 1.53-2.75], patients under the age of 60 years (RR = 1.45, 95% CI 1.07-1.98), patients with a history of previous ADR (RR = 6.51, 95% CI 3.13-13.57), and in the spring season (RR = 1.44, 95% CI 1.07-1.95). The recurrence rate after premedication in patients with previous ADR to CT contrast media was 3.2% (8/247). No deaths occurred that were attributed to the contrast media. The incidence of ADR to nonionic CT contrast media was 0.35%; most of which were mild reactions. Risk factors for ADR included female gender, an age of under 60 years, a history of previous ADR, and spring season.

  6. [Investigation of non-ionizing radiation hazards from physiotherapy equipment in 16 medical institutions].

    Science.gov (United States)

    He, Jia-xi; Zhou, Wei; Qiu, Hai-li; Yang, Guang-tao

    2013-12-01

    To investigate the non-ionizing radiation hazards from physiotherapy equipment in medical institutions and to explore feasible control measures for occupational diseases. On-site measurement and assessment of ultra-high-frequency radiation, high-frequency electromagnetic field, microwave radiation, and laser radiation were carried out in 16 medical institutions using the methods in the Measurement of Physical Agents in Workplace (GBZ/T189-2007). All the investigated medical institutions failed to take effective protective measures against non-ionizing radiation. Of the 17 ultra-short wave therapy apparatus, 70.6%, 47.1%, and 17.64% had a safe intensity of ultra-high-frequency radiation on the head, chest, and abdomen, respectively. Of the 4 external high-frequency thermotherapy apparatus, 100%, 75%, and 75%had a safe intensity of high-frequency electromagnetic field on the head, chest, and abdomen, respectively. In addition, the intensities of microwave radiation and laser radiation produced by the 18 microwave therapy apparatus and 12 laser therapeutic apparatus met national health standards. There are non-ionizing radiation hazards from physiotherapy equipment in medical institutions, and effective prevention and control measures are necessary.

  7. Exposure to non-ionizing electromagnetic radiation and public health : review of safety levels

    International Nuclear Information System (INIS)

    Ubeda, A.; Trillo, M. A.

    2005-01-01

    The potential health effects of the exposure to non-ionizing electromagnetic radiation are a source of increasing interest on the part of the public and the authorities. This article summarizes the theoretical-experimental basis supporting the safety levels proposed by international committees, and reviews the recent scientific literature on non-ionizing radiation's bioeffects that are relevant to the validation or modification of the present exposure limits. Because of its social interest, special consideration is given to power frequency fields (50-60Hz) and to the radio communication signals of mobile telephony. The paper also describes how interpretations of the scientific evidence, other than those of the international committees, have generated some controversy and have provided a basis for more restrictive limits, like those adopted in Europe by Switzerland and Italy. The article also identifies some gaps in the present scientific knowledge on the bioelectromagnetics discipline and proposes that additional research is needed to complete our present knowledge on the biological responses to non-ionizing radiation. (Author) 80 refs

  8. Experiences in excretion urography using iohexol

    Energy Technology Data Exchange (ETDEWEB)

    Russmann, D

    1986-07-14

    The non-ionic contrast medium Iohexol (Omnipaque 300) was used on 125 patients during intravenous excretory urography within the framework of a multicentric study. One third of the patients had already, according to careful anamnesis, experienced allergic reactions; 8% of these had experienced incompatibility after application of a contrast medium. After a short 50 ml or 100 ml infusion, an insignificant general reaction in only one patient could be observed, which abated after a short period. The other 124 patients remained completely free of symptoms. The contrast density achieved was good throughout, during which a mean contrast quantity of approx. 75 ml proved to be the optimum dosage, taking into consideration certain questions and constitution parameters of the patients.

  9. Magnesium sulfate as an oral contrast medium in magnetic resonance imaging of the small intestine.

    Science.gov (United States)

    Shi, Hao; Liu, Cun; Ding, Hong Yu; Li, Chun Wei

    2012-03-01

    To explore the use of magnesium sulfate (MgSO4) as an oral contrast medium (CM) in MRI of the small intestine. By comparing MgSO4 SNRs at different concentrations, we determined that 2.5% MgSO4 is the ideal concentration for small bowel MRI. Twenty volunteers underwent MRI after drinking 2.5% MgSO4. Thirty-one patients with clinical suspicion of small intestinal pathology underwent both MRI and the air-barium contrast examination. The patient's tolerance, side effects and complications were noted. 2.5% MgSO4 can decrease the absorption of water and fully fill the enteric cavity, thereby increasing the contrast between the intestinal wall and lumen and facilitating radiographic examination of the small bowel. The mean diameter of the small intestine was 19.8±1.21 mm in the 20 volunteers consuming 2.5% MgSO4 and 12.7±0.84 mm in the 20 volunteers given water. There was a significant difference (P0.05) in side effects between MgSO4 and water groups. Small intestinal MRI was successfully performed in all 31 patients, who were also examined by the double contrast barium, which gave almost identical diagnoses to MRI in all cases except for 1 patient with small intestinal hemorrhage. MRI with 2.5% MgSO4 can demonstrate intestinal abnormalities. Therefore, 2.5% MgSO4 solution is an ideal oral CM for small bowel MRI. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  10. Effect of X-ray contrast agents on hemostasis and its role in the genesis of adverse reactions

    International Nuclear Information System (INIS)

    Sviridov, N.K.; Napolov, Yu.K.

    2001-01-01

    Based on available data, the effect of X-ray contrast agents (XCA) on homeostasis and its role in side reactions genesis are discussed. It is shown that the contrast agent type used can essentially affect the thrombocytes. Nonionic XCA are able to increase the thrombocytes degranulation in case of coronarography and percutaneous transluminal coronary angioplastics with release of procoagulants in vessel gap. This effect can to lead to acute thromboses and be the start of restenosis [ru

  11. Adverse reactions following administration of contrast media for diagnostic imaging in anaesthetized dogs and cats: a retrospective study.

    Science.gov (United States)

    Scarabelli, Stefania; Cripps, Peter; Rioja, Eva; Alderson, Briony

    2016-09-01

    To evaluate incidences of adverse reaction after the administration of contrast media. Retrospective observational study. Animals included 356 dogs and 58 cats receiving non-ionic iodinated contrast agents, and 425 dogs and 49 cats receiving gadolinium-based contrast agents. Anaesthesia records of dogs and cats receiving intravenous (IV) gadobutrol for magnetic resonance imaging (MRI) or IV iohexol for computed tomography (CT) were reviewed. Changes in pulse rate, respiratory rate and mean arterial pressure at 5 minutes after administration of the contrast medium were evaluated. Changes of 10-20% were considered mild, those of >20% moderate, and reactions that required immediate treatment were considered severe. Associations of sex, age and weight with contrast reaction were investigated using logistic regression. Differences in the incidences of reactions to CT and MRI contrast media were examined with chi-squared tests. A p-value of  0.2). Of dogs receiving iohexol, 64 (18.0%) had mild, 65 (18.3%) had moderate and three (0.8%) had severe reactions. Of dogs receiving gadobutrol, 42 (9.9%) had mild, 87 (20.5%) had moderate and one (0.2%) had a severe reaction. When dogs receiving iohexol were compared with those receiving gadobutrol, the odds ratio of a moderate reaction was 2.0 (95% confidence interval 1.34-3.10; p = 0.001). These estimates did not change substantially after adjustment for age, weight and sex. Severe reactions to iohexol and gadobutrol are rare in dogs and cats; moderate reactions are more likely with iohexol than with gadobutrol. © 2015 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  12. Patient safety and adverse events in contrast medium examinations

    International Nuclear Information System (INIS)

    Enge, I.; Edgren, J.

    1989-01-01

    This volume contains six contributions dealing with the properties, safety and economic aspects (lower risks but higher costs of new low-osmonality contrast media compared to the older high-osmonality, ionic ones) of contrast media used in radiology, and risks involved in procedures for administering of radiologic contrast media. (H.W.). refs.; figs.; tabs

  13. The effect of electrolytes on emulsions stabilized by nonionic surfactants

    NARCIS (Netherlands)

    Boomgaard, van den A.

    1985-01-01

    The objective of this study was to investigate the effect of high electrolyte concentrations on the stability of oil-in-water- emulsions stabilized by nonionic surfactants.

    In chapter 1 several stability mechanisms are briefly outlined and the distinction between coalescence and

  14. Contrast myelography in the diagnosis of posterior hernias of lumbar intervertebral disks

    International Nuclear Information System (INIS)

    Maratkanova, T.V.; Morozova, T.D.

    1997-01-01

    Based on the analysis of the results of 297 contrast myelographies (MG) by means of water soluble agents made in patients with posterior hernias of lumbar intervertebral disks (PHLID), the authors define the potentialities of this technique in the diagnosis of PHLID. Additionally, two oblique X-ray films have been included into the exicting filming routine, which may detect all specific features of intervertebral disk damage at MG. The authors make additions into the wellknown myelographic symptomatology of PHLID, by outlining the abnormal anterior configuration of a contrast column at the level of a diseased disk in PHLID at the foraminal site. The findings suggest that contrast MG with nonionic water-soluble agents is a rather effective technique in the diagnosis of PHLID

  15. Criteria for choice and use of contrast media in intra-arterial D.S.A

    International Nuclear Information System (INIS)

    Dalla-Palma, L.; Stacul, F.; Pozzi-Mucelli, R.

    1985-01-01

    The authors investigated the optimal characteristics of contrast media for use in intra-arterial DSA. 209 injections in 108 patients were evaluated, most of them in the abdominal and peripheral regions. In order to decrease contrast media osmolarity and obtain an adequate mixing with blood, contrast media with low iodine concentration were injected using the same volumes and flow rates of conventional arteriography. Good results were obtained with ionic contrast media, 100 and 150 mgI/ml. depending on the area investigated. The low concentrations allowed the use of ionic agents with an osmolarity very close to that of the non ionic contrast media: the pain has been eliminated and the heat sensation reduced. Furthermore the comparison with the cost of nonionic agents shows a great saving. (orig.)

  16. Role of medium heterogeneity and viscosity contrast in miscible flow regimes and mixing zone growth: A computational pore-scale approach

    Science.gov (United States)

    Afshari, Saied; Hejazi, S. Hossein; Kantzas, Apostolos

    2018-05-01

    Miscible displacement of fluids in porous media is often characterized by the scaling of the mixing zone length with displacement time. Depending on the viscosity contrast of fluids, the scaling law varies between the square root relationship, a sign for dispersive transport regime during stable displacement, and the linear relationship, which represents the viscous fingering regime during an unstable displacement. The presence of heterogeneities in a porous medium significantly affects the scaling behavior of the mixing length as it interacts with the viscosity contrast to control the mixing of fluids in the pore space. In this study, the dynamics of the flow and transport during both unit and adverse viscosity ratio miscible displacements are investigated in heterogeneous packings of circular grains using pore-scale numerical simulations. The pore-scale heterogeneity level is characterized by the variations of the grain diameter and velocity field. The growth of mixing length is employed to identify the nature of the miscible transport regime at different viscosity ratios and heterogeneity levels. It is shown that as the viscosity ratio increases to higher adverse values, the scaling law of mixing length gradually shifts from dispersive to fingering nature up to a certain viscosity ratio and remains almost the same afterwards. In heterogeneous media, the mixing length scaling law is observed to be generally governed by the variations of the velocity field rather than the grain size. Furthermore, the normalization of mixing length temporal plots with respect to the governing parameters of viscosity ratio, heterogeneity, medium length, and medium aspect ratio is performed. The results indicate that mixing length scales exponentially with log-viscosity ratio and grain size standard deviation while the impact of aspect ratio is insignificant. For stable flows, mixing length scales with the square root of medium length, whereas it changes linearly with length during

  17. Micellization and microstructural studies between amphiphilic drug ibuprofen with non-ionic surfactant in aqueous urea solution

    International Nuclear Information System (INIS)

    Rub, Malik Abdul; Azum, Naved; Kumar, Dileep; Asiri, Abdullah M.; Marwani, Hadi M.

    2014-01-01

    Highlights: • Micellization behavior of (ibuprofen + non-ionic surfactant) mixtures has been investigated. • Ion–dipole type of interaction between ibuprofen drug and non-ionic surfactant. • The negative β values propose attractive interactions between the components. • Stern–Volmer binding constants (K sv ) and dielectric constant of mixed systems have also been evaluated. • The results have applicability in drug delivery. - Abstract: Herein, we have accounted for the interaction between a non-steroidal anti-inflammatory drug ibuprofen (IBF) and non-ionic surfactant polyethoxyglycol t-octylphenyl ether (TX-100 (4-(1,1,3,3-tetramethylbutyl)phenyl-polyethylene glycol) and TX-114 ((1,1,3,3-tetramethylbutyl)phenyl-polyethylene glycol)), in aqueous urea solutions using tensiometric and fluorimetric techniques at T = 298.15 K. Surface tension measurements were carried out to evaluate the critical micelle concentrations (cmc) of the drug and surfactant as well as their mixtures of varying compositions. An increase in the surface charge of the micelles was observed with the addition of urea followed by halt of micelles formation. Various physicochemical parameters, such as, cmc values of the mixture, micellar mass fraction (X 1 Rub ) of surfactants (TX-100/TX-114), interaction parameters (β) at the monolayer air–water interface and in bulk solutions, different thermodynamic parameters and activity coefficients (f 1 m ,f 2 m ) for the non-ionic surfactant and drug in the mixed micelles, were determined by using the approach of Clint, of Rubingh, and of Rosen. All results identified synergism and attractive interactions in the mixed systems of (drug–surfactant) mixtures and showed effective involvement of the non-ionic surfactant (TX-100/TX-114) component in the mixture. Micelle aggregation numbers (N agg ), evaluated by using steady-state fluorescence quenching studies, suggest that the contribution of non-ionic surfactant was always more than that of

  18. Delayed allergy-like reactions to X-ray contrast media administration focusing on clinical aspects. First expert meeting

    International Nuclear Information System (INIS)

    Sviridov, N.K.

    1998-01-01

    Materials presented at the first expert meeting of leading specialists in medical radiology are briefly described. The include 14 reports of the scientists of Germany, England, Japan, USA, Finland, Austria. The reports concert delayed allergy-like response to X-ray contrast media accepting on clinical aspects and analysis of nonionic dimeric isotonic media application

  19. Genetic effects of nonionizing electromagnetic fields

    International Nuclear Information System (INIS)

    Lai, Henry

    2001-01-01

    Due to the increased use of electricity and wireless communication devices, there is a concern on whether exposure to nonionizing electromagnetic fields (50/60 Hz fields and radiofrequency radiation) can lead to harmful health effects, particularly, genetic effects and cancer development. This presentation will review recent research on genetic effects of power line frequency and radiofrequency electromagnetic fields. Even though the mechanism of interaction is still unknown, there is increasing evidence that these electromagnetic fields at low intensities can cause genetic damage in cells. There is also evidence suggesting that the effects are caused by oxidative stress. (author)

  20. Biotoxicity and bioavailability of hydrophobic organic compounds solubilized in nonionic surfactant micelle phase and cloud point system.

    Science.gov (United States)

    Pan, Tao; Liu, Chunyan; Zeng, Xinying; Xin, Qiao; Xu, Meiying; Deng, Yangwu; Dong, Wei

    2017-06-01

    A recent work has shown that hydrophobic organic compounds solubilized in the micelle phase of some nonionic surfactants present substrate toxicity to microorganisms with increasing bioavailability. However, in cloud point systems, biotoxicity is prevented, because the compounds are solubilized into a coacervate phase, thereby leaving a fraction of compounds with cells in a dilute phase. This study extends the understanding of the relationship between substrate toxicity and bioavailability of hydrophobic organic compounds solubilized in nonionic surfactant micelle phase and cloud point system. Biotoxicity experiments were conducted with naphthalene and phenanthrene in the presence of mixed nonionic surfactants Brij30 and TMN-3, which formed a micelle phase or cloud point system at different concentrations. Saccharomyces cerevisiae, unable to degrade these compounds, was used for the biotoxicity experiments. Glucose in the cloud point system was consumed faster than in the nonionic surfactant micelle phase, indicating that the solubilized compounds had increased toxicity to cells in the nonionic surfactant micelle phase. The results were verified by subsequent biodegradation experiments. The compounds were degraded faster by PAH-degrading bacterium in the cloud point system than in the micelle phase. All these results showed that biotoxicity of the hydrophobic organic compounds increases with bioavailability in the surfactant micelle phase but remains at a low level in the cloud point system. These results provide a guideline for the application of cloud point systems as novel media for microbial transformation or biodegradation.

  1. Viscosity of iodinated contrast agents during renal excretion

    International Nuclear Information System (INIS)

    Jost, Gregor; Lengsfeld, Philipp; Lenhard, Diana C.; Pietsch, Hubertus; Huetter, Joachim; Sieber, Martin A.

    2011-01-01

    Objective: Modern iodinated non-ionic contrast agents (CAs) can be classified based on their molecular structure into monomeric and dimeric CAs and have at comparable iodine concentrations a different viscosity and osmolality. During their renal excretion, CAs are concentrated in the renal tubuli which might enhance the viscosity difference between monomeric and dimeric CAs. The viscosity of a CA might have an underestimated importance for renal safety, as suggested by recent publications. In this study, we investigated the viscosities of CAs at the concentrations expected to be present in renal tubules. This concentration process was simulated in vitro using dialysis. Furthermore, we investigated urine viscosity and urine flow in rodents after administration of several non-ionic monomeric and dimeric CAs. Materials and methods: To estimate the viscosity of the CAs in vivo, we performed an in vitro dialysis of monomeric and dimeric CAs at various physiological osmolalities of the renal tubulus (290, 400, 500, 700 and 1000 mOsm/kg H 2 O). Following the dialysis, the iodine concentrations and the viscosities of the CAs were determined. Furthermore, to investigate the concentration process in vivo, we measured the urine viscosity and the urine flow in Han Wister rats after the administration of Iopromide, Iohexol, Ioversol, Iomeprol, Iodixanol, and Iosimenol at comparable iodine concentrations. As a control, saline was injected at the same volume. Results: In vitro dialysis of the dimeric CA increased the iodine concentration and strongly increased the viscosity at all tested osmolalities. In contrast, for the monomeric agents an increase in concentration and viscosity was observed only at 700 as well 1000 mOsm/kg H 2 O but to a lesser extent. In summary, dialysis strongly enhanced the viscosity differences between the non-ionic monomeric and dimeric CAs. The administration of dimeric CAs leads to a strong increase in urine viscosity; this was not observed for the

  2. Viscosity of iodinated contrast agents during renal excretion

    Energy Technology Data Exchange (ETDEWEB)

    Jost, Gregor, E-mail: Gregor.Jost@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Lengsfeld, Philipp, E-mail: Philipp.Lengsfeld@bayer.com [Global Medical Affairs Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Lenhard, Diana C., E-mail: Diana.Lenhard@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Pietsch, Hubertus, E-mail: Hubertus.Pietsch@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Huetter, Joachim, E-mail: Joachim.Huetter@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Sieber, Martin A., E-mail: Martin.Sieber@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany)

    2011-11-15

    Objective: Modern iodinated non-ionic contrast agents (CAs) can be classified based on their molecular structure into monomeric and dimeric CAs and have at comparable iodine concentrations a different viscosity and osmolality. During their renal excretion, CAs are concentrated in the renal tubuli which might enhance the viscosity difference between monomeric and dimeric CAs. The viscosity of a CA might have an underestimated importance for renal safety, as suggested by recent publications. In this study, we investigated the viscosities of CAs at the concentrations expected to be present in renal tubules. This concentration process was simulated in vitro using dialysis. Furthermore, we investigated urine viscosity and urine flow in rodents after administration of several non-ionic monomeric and dimeric CAs. Materials and methods: To estimate the viscosity of the CAs in vivo, we performed an in vitro dialysis of monomeric and dimeric CAs at various physiological osmolalities of the renal tubulus (290, 400, 500, 700 and 1000 mOsm/kg H{sub 2}O). Following the dialysis, the iodine concentrations and the viscosities of the CAs were determined. Furthermore, to investigate the concentration process in vivo, we measured the urine viscosity and the urine flow in Han Wister rats after the administration of Iopromide, Iohexol, Ioversol, Iomeprol, Iodixanol, and Iosimenol at comparable iodine concentrations. As a control, saline was injected at the same volume. Results: In vitro dialysis of the dimeric CA increased the iodine concentration and strongly increased the viscosity at all tested osmolalities. In contrast, for the monomeric agents an increase in concentration and viscosity was observed only at 700 as well 1000 mOsm/kg H{sub 2}O but to a lesser extent. In summary, dialysis strongly enhanced the viscosity differences between the non-ionic monomeric and dimeric CAs. The administration of dimeric CAs leads to a strong increase in urine viscosity; this was not observed for

  3. Influence of nonionic surfactants on the potentiometric response of hydrogen ion-selective polymeric membrane electrodes.

    Science.gov (United States)

    Espadas-Torre, C; Bakker, E; Barker, S; Meyerhoff, M E

    1996-05-01

    The influence of poly(ethylene oxide)-based nonionic surfactants (i.e., Triton X-100 and Brij 35) in the sample phase on the response properties of hydrogen ion-selective polymeric membrane electrodes containing mobile (lipophilic amines) or covalently bound (aminated-poly-(vinyl chloride)) hydrogen ion carriers is reported. In the presence of these nonionic surfactants, membrane electrode response toward interfering cation activity (e.g., Na+) in the sample phase is increased substantially and the pH measuring range shortened. The degree of cation interference for pH measurements is shown to correlate with the basicity of the hydrogen ion carrier doped within the membrane phase. The observed deterioration in selectivity arises from the partitioning of the surfactant into the membrane and concomitant extraction of metal cations by the surfactants in the organic phase. The effect of nonionic surfactants on pH electrodes prepared with aminated-PVC membranes is shown to be more complex, with additional large shifts in EMF values apparently arising from multidentate interactions between the surfactant molecules and the polymeric amine in the membrane, leading to a change in the apparent pKa values for the amine sites. The effects induced by nonionic surfactants on the EMF response function of hydrogen ion-selective polymeric membrane electrodes are modeled, and experimental results are shown to correlate well with theoretical predictions.

  4. Small-angle neutron scattering studies of nonionic surfactant: Effect

    Indian Academy of Sciences (India)

    Micellar solution of nonionic surfactant -dodecyloligo ethyleneoxide surfactant, decaoxyethylene monododecyl ether [CH3(CH2)11(OCH2CH2)10OH], C12E10 in D2O solution have been analysed by small-angle neutron scattering (SANS) at different temperatures (30, 45 and 60°C) both in the presence and absence of ...

  5. Exposure to Non-Ionizing Radiation and Public Health: Basic Concepts and Safety Limits

    International Nuclear Information System (INIS)

    Ubeda-Maeso, A.; Vargas-Marcos, F.; Trillo-Ruiz, M.A.

    2003-01-01

    The potential health effects of exposure to non-ionizing electromagnetic radiation in public and residential environments are a source of increasing concern for both the public and authorities on environmental health. This work briefly summarizes the theoretical and experimental bases supporting the safety levels proposed by international committees. It also reviews the recent scientific literature on bioeffects on non-ionizing radiation that may prove potentially relevant to the validation or modification of present exposure limits. Because of their social interest, special consideration will be given to power frequency fields (50-60 Hz) and to the radio communication signals of mobile phones. We will also describe how interpretations of scientific evidence from sources other than international committees have generated some controversy and provided basis for more restrictive limits, such as those adopted in Europe by Switzerland and Italy. In addition, this work identifies some gaps in the present scientific knowledge of bioelectromagnetics. Such gaps are largely responsible for the existing controversy and differences in risk perception. This is why more research aimed at broadening and deepening our understanding of biological responses to non-ionizing radiation is urgently needed. (author)

  6. Simple determination of nonionic surfactants in highly-polluted aqueous samples

    Czech Academy of Sciences Publication Activity Database

    Šváb, M.; Švábová, Martina; Mečířová, P.

    2011-01-01

    Roč. 9, č. 6 (2011), s. 1150-1157 ISSN 1895-1066 Institutional research plan: CEZ:AV0Z30460519 Keywords : nonionic surfactant * soil leachate * spectrophotometric determination Subject RIV: DD - Geochemistry Impact factor: 1.073, year: 2011 http://www.springerlink.com/content/k6401t0237878488/

  7. A Comparison of the Use of Contrast Media with Different Iodine Concentrations for Multidetector CT of the Kidney

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Seung Chai; Kim, Seung Hyup; Cho, Jeong Yeon [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2011-11-15

    To determine the optimal iodine concentration of contrast media for kidney multidetector computed tomography (MDCT) by comparing the degree of renal parenchymal enhancement and the severity of the renal streak artifact with contrast media of different iodine concentrations. A 16-row MDCT was performed in 15 sedated rabbits by injection of 2 mL contrast media/kg body weight at a rate of 0.3 mL/sec. Monomeric nonionic contrast media of 250, 300, and 370 mg iodine/mL were injected at 1-week intervals. Mean attenuation values were measured in each renal structure with attenuation differences among the structures. The artifact was evaluated by CT window width/level and three grading methods. The values were compared with iodine concentrations. The 370 mg iodine/mL concentration showed significantly higher cortical enhancement than 250 mg iodine/mL in all phases (p < 0.05). There was however no significant difference in the degree of enhancement between the 300 mg iodine/mL and 370 mg iodine/mL concentrations in all phases. There is a significant difference in attenuation for the cortex-outer medulla between 250 mg iodine/mL and 300 mg iodine/mL (p < 0.05). The artifact was more severe with a medium of 370 mg iodine/mL than with 250 mg iodine/mL by all grading methods (p < 0.05). The 300 mg iodine/mL is considered to be the most appropriate iodine concentration in an aspect of the enhancement and artifact on a kidney MDCT scan.

  8. Nonionic surfactant organoclay obtaining from Pedra Lavrada District, PB, Brazil

    International Nuclear Information System (INIS)

    Silva, I.A. da; Cardoso, M.A.F.; Figueiredo, J.M.R.; Silva, C.D.; Neves, G.A.; Ferreira, H. C.

    2012-01-01

    The oil industry has invested for many years in the use of smectite clay as a dispersing agent in the composition of drilling fluids for oil wells water based and oil based. The State of Paraiba is one of the largest producers of clays and recently discovered new deposits in the regions of Cubati and Pedra Lavrada by creating a great expectation of the expansion of mineral production in the region. The aim of this work is a smectite clays organophilization of the city of Pedra Lavrada, with the addition of nonionic surfactant. After organophilization clay was characterized by X-ray diffraction and Foster swelling in order to choose the most suitable surfactant through the organic liquid dispersant diesel. The results showed that incorporation of surfactant used in the clay interlayer spacing increased significantly, and that the dispersions showed rheological properties within the specifications of PETROBRAS, for use of organophilic clays in drilling fluids in nonionic base. (author)

  9. Comet assay as a procedure for detecting possible genotoxicity induced by non-ionizing radiation

    Directory of Open Access Journals (Sweden)

    Zsuzsanna Nemeth

    2015-05-01

    In our laboratory we use comet assay for testing genotoxicity of non-ionizing radiation for more than ten years. In the experiments we use whole blood samples (human or dog, cell lines (e.g. H295R cell line or 3 dimensional in vitro skin tissue (epidermis models. In our protocol a slightly modified alkaline Comet assay method of Singh et al. (1988 is used. On our poster there will be presented a brief summary of our experiments with exposure to different types of radiation (ELF, RF, and intermediate frequency. In our protocols the non-ionizing radiation was often combined with ionizing radiation to see whether the non-ionizing radiation can influence the repair of the DNA damage induced by ionizing radiation. For the evaluation of the slides mainly Komet 4.0 image analysis system software (Kinetic Imaging, Liverpool, UK was used, but as we got familiarized with other methods for slide evaluation like grading the comets by visual scoring into 5 categories or the CaspLab software, the comparison of these three methods will be also presented.

  10. Structural study of the continuous medium of spontaneous ternary emulsions

    International Nuclear Information System (INIS)

    Desforge, Christine

    1993-01-01

    This research thesis addresses the study of the structure of a continuous medium of spontaneous ternary emulsions of oil-in-water type, composed of water and octane, and stabilised by means of a cationic surfactant (DDAB, didodecyldimethyl ammonium bromide). It shows that the kinetic stability is due to electrostatic repulsions between octane drops, and that these repulsions are due to the presence of positive charges on the DDAB mono-layer located at the interface between water and oil. Various aspects are highlighted by neutron and X ray scattering. In this study, the DDAB is replaced by a non-ionic surfactant. Its use results in very steady oil/water emulsions [fr

  11. Nonionic surfactant Brij35 effects on toluene biodegradation in a ...

    African Journals Online (AJOL)

    Nonionic surfactant effects on the toluene dissolved in the water phase and biodegradation kinetic behaviors of toluene in a composite bead biofilter were investigated. The toluene dissolved in the water phase was enhanced by the addition of surfactant into aqueous solution and the enhancing effect was more pronounced ...

  12. Prolonged retainment of contrast media in renal tumours by oily X-ray contrast media

    International Nuclear Information System (INIS)

    Ryzkov, V.K.; Anisimov, V.N.

    1990-01-01

    In 194 patients with renal tumours an angiographic investigation with the oily X-ray contrast medium Iodolipol was carried out. A selective tropism of oily X-ray contrast media was found in the malignant zones only. The application of the preparation caused no complications. The oily X-ray contrast medium persisted in the tumours over several weeks or months. After embolization of the renal arteria a moderate size reduction of malign tumours in the first 10-14 d was seen. The ability of Iodolipol for a lasting retainment in malign tumour tissue allows a follow-up of the involution of the pathologic focus after arterial embolization of the tumour vessels. (author)

  13. Outcome Differences between Intra-Arterial Iso- and Low-Osmolality Iodinated Radiographic Contrast Media in the Interventional Management of Stroke III Trial.

    Science.gov (United States)

    Tomsick, T A; Foster, L D; Liebeskind, D S; Hill, M D; Carrozella, J; Goyal, M; von Kummer, R; Demchuk, A M; Dzialowski, I; Puetz, V; Jovin, T; Morales, H; Palesch, Y Y; Broderick, J; Khatri, P; Yeatts, S D

    2015-11-01

    Intracarotid arterial infusion of nonionic, low-osmolal iohexol contrast medium has been associated with increased intracranial hemorrhage in a rat middle cerebral artery occlusion model compared with saline infusion. Iso-osmolal iodixanol (290 mOsm/kg H2O) infusion demonstrated smaller infarcts and less intracranial hemorrhage compared with low-osmolal iopamidol and saline. No studies comparing iodinated radiographic contrast media in human stroke have been performed, to our knowledge. We hypothesized that low-osmolal contrast media may be associated with worse outcomes compared with iodixanol in the Interventional Management of Stroke III Trial (IMS III). We reviewed prospective iodinated radiographic contrast media data for 133 M1 occlusions treated with endovascular therapy. We compared 5 prespecified efficacy and safety end points (mRS 0-2 outcome, modified TICI 2b-3 reperfusion, asymptomatic and symptomatic intracranial hemorrhage, and mortality) between those receiving iodixanol (n = 31) or low-osmolal contrast media (n = 102). Variables imbalanced between iodinated radiographic contrast media types or associated with outcome were considered potential covariates for the adjusted models. In addition to the iodinated radiographic contrast media type, final covariates were those selected by using the stepwise method in a logistic regression model. Adjusted relative risks were then estimated by using a log-link regression model. Of baseline or endovascular therapy variables potentially linked to outcome, prior antiplatelet agent use was more common and microcatheter iodinated radiographic contrast media injections were fewer with iodixanol. Relative risk point estimates are in favor of iodixanol for the 5 prespecified end points with M1 occlusion. The percentage of risk differences are numerically greater for microcatheter injections with iodixanol. While data favoring the use of iso-osmolal iodixanol for reperfusion of M1 occlusion following IV rtPA are

  14. Radiation protection problems by nonionizing electromagnetic radiation in Austria

    International Nuclear Information System (INIS)

    Duftschmid, K.E.

    1984-03-01

    Since about one year an interdisciplinary study group has been established to investigate possible radiation protection problems caused by nonionizing electromagnetic radiation in this country. The aim of this project is to identify major fields of concern, to establish appropriate techniques of measurement and control and eventually develop a sound basis for future legislation. The paper gives a summary on the present results of this study. (Author)

  15. Contrast Medium Induced Nephropathy after Endovascular Stent Graft Placement: An Examination of Its Prevalence and Risk Factors

    International Nuclear Information System (INIS)

    Kawatani, Yohei; Nakamura, Yoshitsugu; Mochida, Yoshihiko; Yamauchi, Naoya; Hayashi, Yujiro; Taneichi, Tetsuyoshi; Ito, Yujiro; Kurobe, Hirotsugu; Suda, Yuji; Hori, Takaki

    2016-01-01

    Endovascular stent graft placement has become a major treatment for thoracic and abdominal aneurysms. While endovascular therapy is less invasive than open surgery, it involves the use of a contrast medium. Contrast media can cause renal impairment, a condition termed as contrast-induced nephropathy (CIN). This study sought to evaluate the incidence and risk factors of CIN following endovascular stent graft placement for aortic aneurysm repair. The study included 167 consecutive patients who underwent endovascular stent graft placement in our hospital from October 2013 to June 2014. CIN was diagnosed using the European Society of Urogenital Radiology criteria. Patients with and without CIN were compared. Chi-squared tests, t-tests, and multivariate logistic regression analyses were performed. Thirteen patients (7.8%) developed CIN. Left ventricular dysfunction and intraoperative blood transfusion were significantly more frequent in the CIN group (P = 0.017 and P = 0.032, resp.). Multivariate analysis showed that left ventricular dysfunction had the strongest influence on CIN development (odds ratio 9.34, P = 0.018, and 95% CI = 1.46–59.7). Patients with CIN also experienced longer ICU and hospital stays. Measures to improve renal perfusion flow should be considered for patients with left ventricular dysfunction who are undergoing endovascular stent graft placement

  16. Exposure to non-ionizing radiation provokes changes in rat thyroid morphology and expression of HSP-90

    OpenAIRE

    Misa-Agustiño, Maria J; Jorge-Mora, Teresa; Jorge-Barreiro, Francisco J; Suarez-Quintanilla, Juan; Moreno-Piquero, Eduardo; Ares-Pena, Francisco J; López-Martín, Elena

    2015-01-01

    Non-ionizing radiation at 2.45 GHz may modify the morphology and expression of genes that codify heat shock proteins (HSP) in the thyroid gland. Diathermy is the therapeutic application of non-ionizing radiation to humans for its beneficial effects in rheumatological and musculo-skeletal pain processes. We used a diathermy model on laboratory rats subjected to maximum exposure in the left front leg, in order to study the effects of radiation on the nearby thyroid tissue. Fifty-six rats were i...

  17. Use of high concentration contrast media: principles and rationale--vascular district

    International Nuclear Information System (INIS)

    Fleischmann, Dominik.

    2003-01-01

    Optimal contrast medium delivery remains a crucial issue in CT angiography and it will become even more critical with continuously evolving, faster CT scanner technology. This review article first explains the fundamentals of arterial enhancement using mathematical models of early contrast medium dynamics. The relationship of contrast medium volume, injection flow rates and injection duration are explicitly illustrated. Next, current techniques of contrast medium application are reviewed, with particular attention to methods of accurate timing of the scanning delay (test-bolus and automated bolus triggering), tools for automated saline-flushing of the veins (double-syringe power injectors) and the use of high-concentration contrast medium. From there, rational CT angiographic injection protocols for a wide range of selectable acquisition times for 4-, 8- and 16-channel MDCT are proposed

  18. Iodine-based contrast media, multiple myeloma and monoclonal gammopathies: literature review and ESUR Contrast Media Safety Committee guidelines.

    Science.gov (United States)

    Stacul, Fulvio; Bertolotto, Michele; Thomsen, Henrik S; Pozzato, Gabriele; Ugolini, Donatella; Bellin, Marie-France; Bongartz, Georg; Clement, Olivier; Heinz-Peer, Gertraud; van der Molen, Aart; Reimer, Peter; Webb, Judith A W

    2018-02-01

    Many radiologists and clinicians still consider multiple myeloma (MM) and monoclonal gammopathies (MG) a contraindication for using iodine-based contrast media. The ESUR Contrast Media Safety Committee performed a systematic review of the incidence of post-contrast acute kidney injury (PC-AKI) in these patients. A systematic search in Medline and Scopus databases was performed for renal function deterioration studies in patients with MM or MG following administration of iodine-based contrast media. Data collection and analysis were performed according to the PRISMA statement 2009. Eligibility criteria and methods of analysis were specified in advance. Cohort and case-control studies reporting changes in renal function were included. Thirteen studies were selected that reported 824 iodine-based contrast medium administrations in 642 patients with MM or MG, in which 12 unconfounded cases of PC-AKI were found (1.6 %). The majority of patients had intravenous urography with high osmolality ionic contrast media after preparatory dehydration and purgation. MM and MG alone are not risk factors for PC-AKI. However, the risk of PC-AKI may become significant in dehydrated patients with impaired renal function. Hypercalcaemia may increase the risk of kidney damage, and should be corrected before contrast medium administration. Assessment for Bence-Jones proteinuria is not necessary. • Monoclonal gammopathies including multiple myeloma are a large spectrum of disorders. • In monoclonal gammopathy with normal renal function, PC-AKI risk is not increased. • Renal function is often reduced in myeloma, increasing the risk of PC-AKI. • Correction of hypercalcaemia is necessary in myeloma before iodine-based contrast medium administration. • Bence-Jones proteinuria assessment in myeloma is unnecessary before iodine-based contrast medium administration.

  19. A Review on the Environmental Behavior of the Polyoxyethylene Type Nonionic Surfactants Adjuvants in Pesticides

    Directory of Open Access Journals (Sweden)

    KONG Xiang-ji

    2017-05-01

    Full Text Available Polyoxyethylene type nonionic surfactants such as alkylphenol ethoxylates(APEOs, alcohol ethoxylates(AEOs and alkylamine ethoxylates(ANEOs are typical pesticide adjuvants. Their unique environmental behavior characteristic is reflected in the parameters describing the fate e.g.distribution coefficient, adsorption to soil, degradation and effects of these substances. The major environmental problem related to these compounds is their part metabolites' relatively higher environmental risk. In views of their chemical structure, this paper outlined present knowledge on occurrence, fate and environment effect of the three adjuvants:AEOs, ANEOs and APEOs. The adsorption behaviour of ANEOs in contrast to AEOs was particularly variable and matrix dependent due to the ability of the compound to ionise at environmentally relevant pH. Probably because the compounds exceeded high soil adsorption and were easily degradable which were reflected in the low environmental concentrations generally found in monitoring studies.

  20. Biological effects of low-level ionizing and non-ionizing radiation

    International Nuclear Information System (INIS)

    Upton, A.C.

    1986-01-01

    Early in this century it was recognized that large doses of ionizing radiation could injure almost any tissue in the body, but small doses were generally thought to be harmless. By the middle of the century however it came to be suspected that even the smallest doses of ionizing radiation to the gonads might increase the risk of hereditary disease in subsequently-conceived offspring. Since then the hypothesis that carcinogenic and teratogenic effects also have no threshold has been adopted for purposes of radiological protection. It is estimated nevertheless that the risks that may be associated with natural background levels of ionizing irradiation are too small to be detectable. Hence validation of such risk estimates will depend on further elucidation of the dose-effect relationships and mechanisms of the effects in question, through studies at higher dose levels. In contrast to the situation with ionizing radiation, exposure to natural background levels of ultraviolet radiation has been implicated definitively in the etiology of skin cancers in fair-skinned individuals. Persons with inherited effects in DNA repair capacity are particularly susceptible. Non-ionizing radiations of other types can also affect health at high dose levels, but whether they can cause injury at low levels of exposure is not known

  1. Synergism and Physicochemical Properties of Anionic/Amphoteric Surfactant Mixtures with Nonionic Surfactant of Amine Oxide Type

    Science.gov (United States)

    Blagojević, S. M.; Pejić, N. D.; Blagojević, S. N.

    2017-12-01

    The physicochemical properties of initial formulation, that is anionic/amphoteric surfactants mixture SLES/AOS/CAB (sodium lauryl ether sulfate (SLES), α-olefin sulfonates (AOS) and cocamidopropyl betaine (CAB) at ratio 80 : 15 : 5) with nonionic surfactant of amine oxide type (lauramine oxide (AO)) in various concentration (1-5%) were studied. To characterize the surfactants mixture, the critical micelle concentration (CMC), surface tension (γ), foam volume, biodegradability and irritability were determined. This study showed that adding of AO in those mixtures lowered both γ and CMC as well as enhanced SLES/AOS/CAB foaming properties, but did not significantly affect biodegradability and irritability of initial formulation. Moreover, an increase in AO concentration has a meaningful synergistic effect on the initial formulation properties. All those results indicates that a nonionic surfactant of amine oxide type significantly improves the performance of anionic/amphoteric mixed micelle systems, and because of that anionic/amphoteric/nonionic mixture can be used in considerably lower concentrations as a cleaning formulation.

  2. Influence of osmolarity of contrast medium and saline flush on computed tomography angiography: Comparison of monomeric and dimeric iodinated contrast media with different iodine concentrations at an identical iodine delivery rate

    International Nuclear Information System (INIS)

    Kishimoto, Miori; Doi, Shoko; Shimizu, Junichiro; Lee, Ki-Ja; Iwasaki, Toshiroh; Miyake, Yoh-Ichi; Yamada, Kazutaka

    2010-01-01

    Purpose: To evaluate the influence of osmolarity of iodinated contrast media and saline flush on the contrast effect in thoracic computed tomography angiography (CTA) at an identical iodine delivery rate (IDR). Materials and methods: Seven beagles were used in a cross-over experiment. The contrast media used were iohexol 350 mgI/ml (IOH350; osmolarity 844 mmol/kg) and iodixanol 320 mgI/ml (IDX320; osmolarity 290 mmol/kg). Each contrast medium was administered to groups with and without saline flush at 40.0 mgI/kg/s for all experiments. Dynamic CT scanning was performed at the ninth thoracic vertebra level. The peak value, area under the curve (AUC), and time to peak (TTP) were calculated from the time attenuation curves of the pulmonary artery and aorta. Results: There was no significant difference between IOH350 and IDX320 with or without saline flush in the peak values for the pulmonary artery and aorta. AUC was significantly higher in groups with saline flush for both contrast media and arteries (p < 0.05) with no significant difference between contrast media. TTP was significantly longer in groups with saline flush than without saline flush for both contrast media and arteries (p < 0.05), with no significant difference between contrast media. Conclusions: There were no significant differences in the contrast effects of monomeric IOH350 and dimeric IDX320 in thoracic CTA when used at an identical IDR. Moreover, saline flush prolonged the peak duration at 600 mgI/kg.

  3. Small angle neutron scattering study of two nonionic surfactants in ...

    Indian Academy of Sciences (India)

    nonionic surfactants in water micellar solutions. RAJEWSKA ALDONA. Institute of ... water solution for concentration c = 0.17% (dilute regime) at different temperatures in the range t = 10–35°C by small .... which yields the pair distance distribution function p(r), where r is the distance in real space. The point, at which the p(r) ...

  4. Consideration of Adverse Reaction to MDCT Contrast Media

    International Nuclear Information System (INIS)

    Yang, Won Seok; Shin, Seong Gyu

    2012-01-01

    In this experiment, we investigated 82 patients who suffered adverse reactions due to contrast medium. We selected the subjects out of 21,178 people who had an intravenous injection of contrast medium to undergo MDCT examination at one university hospital in Busan in 2007. As a result, the largest groups of the patients were as follows. 52.4% of the patients were male when classify by gender; 28.0% of the patients were 50's by age; 45% of the patients got when it was spring(April and March); 75.6% of the patients had a side effects when the speed of injection is 2.5 mL/sec; 58.5% of the patients were suffered when the volume of injected contrast medium is over 130 mL. Urticaria was the main symptom of side effect as 26.8%. And the main treatment for the effect was alleviating the symptoms before making patients to return home. Thus, practical preventive measures are needed as follows: use the OCS system to observe warning signs at risky patients, secure warming spaces for patients to cope with season changing, prepare enough emergency kits for the patients in danger, and establish CPR call systems, explain the risk of contrast medium and get agree about using contrast medium.

  5. Iohexol and ioxaglate in peripheral angiography

    International Nuclear Information System (INIS)

    Stiris, M.G.; Laerum, F.

    1987-01-01

    A double-blind, cross-over trial of the non-ionic, low-osmolar contrast medium iohexol (Omnipaque) and the ionic, low-osmolar medium ioxaglate (Hexabrix) at concentrations of 300 mg I/ml was carried out in 107 consecutive patients with arterial insufficiency of the lower limbs. The purpose of the study was to observe possible 'carry-over' effects from any of the contrast media, and to evaluate patient discomfort such as pain, adverse reactions, or effect on peripheral blood pressure. No carry-over effect was seen. Ioxaglate caused less injection pain and heat sensations than iohexol, and showed less effect on the systemic blood pressure. (orig.)

  6. A Comparison of the Use of Contrast Media with Different Iodine Concentrations for Multidetector CT of the Kidney

    Science.gov (United States)

    Jung, Seung Chai; Cho, Jeong Yeon

    2011-01-01

    Objective To determine the optimal iodine concentration of contrast media for kidney multidetector computed tomography (MDCT) by comparing the degree of renal parenchymal enhancement and the severity of the renal streak artifact with contrast media of different iodine concentrations. Materials and Methods A 16-row MDCT was performed in 15 sedated rabbits by injection of 2 mL contrast media/kg body weight at a rate of 0.3 mL/sec. Monomeric nonionic contrast media of 250, 300, and 370 mg iodine/mL were injected at 1-week intervals. Mean attenuation values were measured in each renal structure with attenuation differences among the structures. The artifact was evaluated by CT window width/level and three grading methods. The values were compared with iodine concentrations. Results The 370 mg iodine/mL concentration showed significantly higher cortical enhancement than 250 mg iodine/mL in all phases (p < 0.05). There was however no significant difference in the degree of enhancement between the 300 mg iodine/mL and 370 mg iodine/mL concentrations in all phases. There is a significant difference in attenuation for the cortex-outer medulla between 250 mg iodine/mL and 300 mg iodine/mL (p < 0.05). The artifact was more severe with a medium of 370 mg iodine/mL than with 250 mg iodine/mL by all grading methods (p < 0.05). Conclusion The 300 mg iodine/mL is considered to be the most appropriate iodine concentration in an aspect of the enhancement and artifact on a kidney MDCT scan. PMID:22043154

  7. Effect of contrast media iodine concentration on bolus tracking

    International Nuclear Information System (INIS)

    Ishihara, Toshihiro; Hayashi, Takayuki; Nakaya, Yoshihiro; Naoi, Kuniji; Ikeno, Naoya; Kobayashi, Tatsushi; Satake, Mitsuo

    2006-01-01

    Computer-assisted bolus tracking has been confirmed to be a useful technique in computed tomography (CT) imaging and allows images to be captured with automated timing. The inflow of the contrast medium is monitored, and when the contrast medium reaches a predetermined level, CT image capture starts automatically. However, it has been shown that the preset threshold value of contrast medium is affected by its iodine concentration, which causes variations in image capture times. Greater speed in current multislice CT imaging requires that medical technicians pay more attention to setting the timing of image capture during venous examinations by taking into account the iodine concentration in contrast media. (author)

  8. [Development of recommendations in the area of ionizing and nonionizing radiations

    International Nuclear Information System (INIS)

    1990-01-01

    This document discusses progress made from March 1, 1990 to October 30, 1990 in terms of publication of reports. This subjects discussed are related to the fields of radiation protection and ionizing and nonionizing radiations. Topics discussed published works, reports in press, printer's manuscript preparation, and scientific committee activities

  9. Non-ionizing radiation as threat in daily life | Syaza | Journal of ...

    African Journals Online (AJOL)

    Electromagnetic field (EMF) is a field of combination between electric and magnetic field. While electromagnetic radiation (EMR) can be divided into ionizing and non-ionizing radiation (NIR). This article review of published scientific studies about NIR and its effect on the human body. From this review, it is found that NIR ...

  10. MRI with intrathecal MRI gadolinium contrast medium administration: a possible method to assess glymphatic function in human brain

    International Nuclear Information System (INIS)

    Eide, Per Kristian; Ringstad, Geir

    2015-01-01

    Recently, the “glymphatic system” of the brain has been discovered in rodents, which is a paravascular, transparenchymal route for clearance of excess brain metabolites and distribution of compounds in the cerebrospinal fluid. It has already been demonstrated that intrathecally administered gadolinium (Gd) contrast medium distributes along this route in rats, but so far not in humans. A 27-year-old woman underwent magnetic resonance imaging (MRI) with intrathecal administration of gadobutrol, which distributed throughout her entire brain after 1 and 4.5 h. MRI with intrathecal Gd may become a tool to study glymphatic function in the human brain

  11. MRI with intrathecal MRI gadolinium contrast medium administration: a possible method to assess glymphatic function in human brain.

    Science.gov (United States)

    Eide, Per Kristian; Ringstad, Geir

    2015-11-01

    Recently, the "glymphatic system" of the brain has been discovered in rodents, which is a paravascular, transparenchymal route for clearance of excess brain metabolites and distribution of compounds in the cerebrospinal fluid. It has already been demonstrated that intrathecally administered gadolinium (Gd) contrast medium distributes along this route in rats, but so far not in humans. A 27-year-old woman underwent magnetic resonance imaging (MRI) with intrathecal administration of gadobutrol, which distributed throughout her entire brain after 1 and 4.5 h. MRI with intrathecal Gd may become a tool to study glymphatic function in the human brain.

  12. Addition of lacal anesthetics to contrast media. Pt. 2

    International Nuclear Information System (INIS)

    Nilsson, P.; Almen, T.; Golman, K.; Jonsson, K.; Nyman, U.; Malmoe Allmaenna Sjukhus

    1988-01-01

    The acute intravenous toxicity (i.v. LD 50 ) of solutions of the ratio 1.5 contrast media metrizoate or diatrizoate and the ratio 3.0 contrast medium metrizamide was determined in mice with and without the addition of local anesthetics to the solutions. The two local anesthetics mepivacaine or lidocaine were added to final concentrations up to 2.0 mg/ml of the contrast medium solutions. This corresponds to clinically used concentrations. All additions of local anesthetics to the solutions increased the mortalities caused by the contrast medium solutions. Addition of local anesthetics to a final concentration of 2 mg/ml approximately doubled the acute intravenous toxicity of the contrast media. The ratio 3 contrast media produce less hypertonic solutions than the ratio 1.5 contrast media and should be preferred for angiography because they cause less pain and do not require the addition of local anesthetics which increase the acute toxicity of the solutions. (orig.)

  13. Contrast media in computed tomography of the pelvic organs

    International Nuclear Information System (INIS)

    Husband, J.E.

    1981-01-01

    The use of various contrast media is essential for examination of the pelvis with computed tomography (CT) because there is little fat between the organs and structures and because bowel may be misinterpreted as mass. Routine opacification of the distal small bowel and colon is achieved using dilute oral and rectal contrast medium, and all patients are scanned with a full bladder. A tampon is used to outline the vaginal vault. Intravenous contrast medium may be required to opacify the urinary tract or to distinguish vessels from a suspected space-occupying lesion. Pelvic masses may show tissue enhancement following injection of intravenous contrast medium but further studies are required to determine the diagnostic value of the information obtained. (Auth.)

  14. Hydration for the prevention of contrast medium-induced nephropathy. An update

    International Nuclear Information System (INIS)

    Heinrich, M.; Uder, M.

    2006-01-01

    Contrast medium-induced nephropathy (CIN) continues to be one of the most common causes of hospital-acquired acute renal failure. Since most of the clinical studies on the prophylactic use of different drugs to prevent CIN produced disappointing results, hydration remains the mainstay of prophylaxis. A number of recent prospective randomized trials provided further evidence of the effectiveness of hydration and relevant information regarding the optimization of hydration protocols. It was shown that a bolus hydration solely during examination is not sufficient to prevent CIN. In addition, isotonic 0.9% saline was superior to the commonly used halfisotonic 0.45% saline in another trial. An outpatient hydration protocol including oral hydration before the examination followed by forced intravenous hydration over 6 hrs. beginning 30 to 60 min. prior to examination seems to be comparable to the usual hydration over 24 hrs. Another hydration protocol, which could also be very attractive especially for outpatients, included the infusion of sodium bicarbonate. In a recent trial, hydration with sodium bicarbonate, given as a bolus for 1 hr. prior to examination followed by an infusion for 6 hrs. after examination, was more effective than hydration with sodium chloride for the prophylaxis of CIN. However, there is still a lack of large-scale, multi-center trials comparing different hydration protocols and investigating their influence on clinically relevant endpoints such as mortality or the need for dialysis. (orig.)

  15. Fundamental study of DSA images using gadolinium contrast agent

    International Nuclear Information System (INIS)

    Nagashima, Hiroyuki; Shiraishi, Akihisa; Igarashi, Hitoshi; Sakamoto, Hajime; Sano, Yoshitomo

    2002-01-01

    Most contrast agents used in digital subtraction angiography (DSA) are non-ionic iodinated contrast agents, which can cause severe side effects in patients with contraindications for iodine or allergic reactions to iodine. Therefore, DSA examinations using carbon dioxide gas or examinations done by magnetic resonance imaging (MRI) and ultrasound (US) were carried out in these patients. However, none of these examinations provided mages as clear as those of DSA with an iodinated contrast agent. We experienced DSA examination using a gadolinium contrast agent in a patient contraindicated for iodine. The patient had undergone MRI examination with a gadolinium contrast agent previously without side effects. The characteristics of gadolinium and the iodinated contrast agent were compared, and the DSA images obtained clinically using these media were also evaluated. The signal-to-noise (SN) ratio of the gadolinium contrast agent was the highest at tube voltages of 70 to 80 kilovolts and improved slightly when the image intensifier (I.I.) entrance dose was greater than 300 μR (77.4 nC/kg). The dilution ratios of five iodinated contrast agents showed the same S/N value as the undiluted gadolinium contrast agent. Clinically, the images obtained showed a slight decrease in contrast but provided the data necessary to make a diagnosis and made it possible to obtain interventional radiology (IVR) without any side effects. DSA examinations using a gadolinium contrast agent have some benefit with low risk and are thought to be useful for patients contraindicated for iodine. (author)

  16. Contrast-enhanced MR imaging monitoring of acute tumor response to chemotherapy

    International Nuclear Information System (INIS)

    Ranney, D.F.; Cohen, J.M.; Antich, P.P.; Endman, W.A.; Kulkarni, P.; Weinreb, J.C.; Giovanella, B.

    1987-01-01

    Treatment responses of human malignant melanomas were monitored at millimeter resolution in athymic mice by injecting a new polymeric contrast agent, Gd-DTPA-dextran (0.1 mmol Gd/kg, intravenously). Proton MR imaging (0.35 T, spin-echo, repetition time = 0.5 second, echo time = 50 msec) was performed 30 hours after administering diphtheria toxin. Pre-contrast medium images revealed only homogeneous intermediate-intensity tumor masses. Post-contrast medium images of untreated (viable) tumors demonstrated 32% enhancement throughout the entire mass. Post-contrast medium images of toxin-treated tumors revealed marked enhancement (65%) of the histologically viable outer rims, lesser enhancement (38%) of heavily damaged subregions, and no enhancement of dead tumor. These acute, contrast medium-enhanced MR images accurately identified tumor subregions that survived for longer than one week

  17. Iohexol for contrast enhancement of bowel in pediatric abdominal CT

    International Nuclear Information System (INIS)

    Smevik, B.; Westvik, J.

    1990-01-01

    Abdominal CT scans from 160 examinations performed on pediatric patients using iohexol 2 percent as contrast medium for bowel enhancement were evaluated retrospectively. When diluted with a beverage of the child's choice, iohexol has a neutral taste and cannot be detected, and 139 out of 142 patients drank the full amount of dilute contrast offered to them. The enhancement of bowel in the area of interest was graded as good (58%), reasonable (23%), or poor (19%). The contrast medium was prepared from leftovers from our angiocardiography studies. We conclude that the use of water-soluble contrast medium in a low concentration is a safe and cost-effective way of facilitating ingesion of sufficient amounts of the medium in oncologic pediatric patients undergoing cytotoxic and/or radiation treatment. (orig.)

  18. Value of intravenous injection of contrast media for computerized tomography of the thorax

    International Nuclear Information System (INIS)

    Beyer-Enke, S.A.; Goerich, J.; Mueller, M.; Kaick, G. van; Tuengerthal, S.

    1988-01-01

    107 patients with thoracal or mediastinal growths underwent computerized tomography of the thorax both in normal condition and after receiving intravenous applications of non-ionic X-ray contrast media. The additional information obtained by use of contrast media was established in relation to the histological findings. The method led to enhanced demarcation of the tumor of the mediastinum or hilus in 40% of the patients. Tumor perfusion was helpful in 20% of the cases for differential diagnosis. Vessel infiltrations or abnormal conditions were found in about 30% of patients. 24% of the tests yielded no additional information. Analysing CT as compared to the histological examination of lymph nodes proved CT under normal conditions to be a sensitive method in 29% of cases if the hilus was the site of the tumor; contrast media raised this sensitivity to 43%. In the mediastinal area, sensitivity was 44% without and 56% with contrast media. (orig.) [de

  19. Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tube-voltage technique: Feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Minwen, E-mail: zhengmw2007@163.com; Liu, Ying, E-mail: yingyinglyly@126.com; Wei, Mengqi, E-mail: weimengqi2008@163.com; Wu, Yongjie, E-mail: wu18291988526@163.com; Zhao, Hongliang, E-mail: zhaohl1980@163.com; Li, Jian, E-mail: xjyylj@yeah.net

    2014-02-15

    Objectives: To assess the impact of low-concentration contrast medium on vascular enhancement, image quality and radiation dose of coronary CT angiography (cCTA) by using a combination of iterative reconstruction (IR) and low-tube-voltage technique. Materials and methods: One hundred patients were prospectively randomized to two types of contrast medium and underwent prospective electrocardiogram-triggering cCTA (Definition Flash, Siemens Healthcare; collimation: 128 mm × 0.6 mm; tube current: 300 mA s). Fifty patients received Iopromide 370 were scanned using the conventional tube setting (100 kVp or 120 kVp if BMI ≥ 25 kg/m{sup 2}) and reconstructed with filtered back projection (FBP). Fifty patients received Iodixanol 270 were scanned using the low-tube-voltage (80 kVp or 100 kVp if BMI ≥ 25 kg/m{sup 2}) technique and reconstructed with IR. CT attenuation was measured in coronary artery and other anatomical regions. Noise, image quality and radiation dose were compared. Results: Compared with two Iopromide 370 subgroups, Iomeprol 270 subgroups showed no significant difference in CT attenuation (576.63 ± 95.50 vs. 569.51 ± 118.93 for BMI < 25 kg/m{sup 2}, p = 0.647 and 394.19 ± 68.09 vs. 383.72 ± 63.11 for BMI ≥ 25 kg/m{sup 2}, p = 0.212), noise (in various anatomical regions of interest) and image quality (3.5 vs. 4.0, p = 0.13), but significantly (0.41 ± 0.17 vs. 0.94 ± 0.45 for BMI < 25 kg/m{sup 2}, p < 0.001 and 1.14 ± 0.24 vs. 2.37 ± 0.69 for BMI ≥ 25 kg/m{sup 2}, p < 0.001) lower radiation dose, which reflects dose saving of 56.4% and 51.9%, respectively. Conclusions: Combined IR with low-tube-voltage technique, a low-concentration contrast medium of 270 mg I/ml can still maintain the contrast enhancement without impairing image quality, as well as significantly lower the radiation dose.

  20. Effects of acetylcysteine and probucol on contrast medium-induced depression of intrinsic renal glutathione peroxidase activity in diabetic rats.

    Science.gov (United States)

    Yen, Hsueh-Wei; Lee, Hsiang-Chun; Lai, Wen-Te; Sheu, Sheng-Hsiung

    2007-04-01

    Antioxidants such as N-acetylcysteine and probucol have been used to protect patients from contrast media-induced nephrotoxicity. The mechanisms underlying these protective effects are not well understood. We hypothesized that acetylcysteine and probucol alter the activity of endogenous antioxidant enzyme activity. Four weeks after induction of diabetes with streptozotocin, diabetic and nondiabetic rats were divided into three groups. Group 1 rats did not receive any antioxidant agents. Group 2 rats were treated with acetylcysteine and group 3 rats with probucol for 1 week before injection of the contrast medium diatrizoate (DTZ). We found that diabetic rats had higher renal glutathione peroxidase (GPx) activity than normal rats. DTZ suppressed renal GPx activity significantly in both group 1 diabetic and normal rats. Interestingly, renal GPx activity in both diabetic and normal rats pretreated with acetylcysteine or probucol was not inhibited by DTZ. Renal superoxide dismutase (SOD) increased significantly in normal rats after DTZ injection, but not in diabetic rats. Finally, acetylcysteine or probucol did not significantly influence renal SOD. These findings suggest that the renal protective effects of acetylcysteine and probucol against contrast-induced oxidative stress and nephrotoxicity may be mediated by altering endogenous GPx activity.

  1. USING CERAMIC MEMBRANES TO RECYCLE TWO NONIONIC ALKALINE METAL-CLEANING SOLUTIONS

    Science.gov (United States)

    One ZrO2 ultrafilter (0.05 um pore size) and two a-Al2O3 microfilters (0.2 and 0.8 um) were used to remove one synthetic ester oil and two polyalphaolefin-based and two petroleum hydrocarbon-based oils and greases from two nonionic alkaline cleaning solutions (e.g., Turco 4215-NC...

  2. Thin films deposited by laser ablation for the measurement of the ionizing and non-ionizing radiation

    International Nuclear Information System (INIS)

    Villarreal B, J.E.; Escobar A, L.; Camps, E.; Romero, S.; Gonzalez, P.; Salinas, B.

    2001-01-01

    In this work the obtained results to synthesize thin films of amorphous carbon with incorporated nitrogen and hydrogen are presented, as well as thin films of aluminium oxide using the laser ablation technique. The thin films were exposed to ionizing radiation (gamma rays of a 60 Co source, beta radiation of a 90 Sr source) and a non-ionizing radiation (UV radiation). The obtained results show that it is possible to obtain materials in thin film form with thickness of hundreds of nanometers, which present thermoluminescent response when being irradiated with ionizing radiation and non-ionizing radiation. (Author)

  3. Interaction between cholesterol and non-ionic surfactants studied by thin-layer chromatography

    Czech Academy of Sciences Publication Activity Database

    Forgács, E.; Cserháti, T.; Farkas, O.; Eckhardt, Adam; Mikšík, Ivan; Deyl, Zdeněk

    2004-01-01

    Roč. 27, č. 13 (2004), s. 1981-1992 ISSN 1082-6076 Grant - others:CZ-HU(CZ) Cooperation program Institutional research plan: CEZ:AV0Z5011922 Keywords : cholesterol * non-ionic surfactant * thin - layer chromatography Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.836, year: 2004

  4. Bio-effects of non-ionizing electromagnetic fields in context of cancer therapy.

    Science.gov (United States)

    Saliev, Timur; Tachibana, Katsuro; Bulanin, Denis; Mikhalovsky, Sergey; Whitby, Ray D L

    2014-01-01

    Bio-effects mediated by non-ionizing electromagnetic fields (EMF) have become a hot topic of research in the last decades. This interest has been triggered by a growing public concern about the rapid expansion of telecommunication devices and possible consequences of their use on human health. Despite a feasibility study of potential negative impacts, the therapeutic advantages of EMF could be effectively harnessed for the treatment of cancer and other diseases. This review aims to examine recent findings relating to the mechanisms of action underlying the bio-effects induced by non-ionizing EMF. The potential of non-thermal and thermal effects is discussed in the context of possible applications for the induction of apoptosis, formation of reactive oxygen species, and increase of membrane permeability in malignant cells. A special emphasis has been put on the combination of EMF with magnetic nano-particles and ultrasound for cancer treatment. The review encompasses both human and animal studies.

  5. A method for the investigation of cholegraphic contrast media

    International Nuclear Information System (INIS)

    Otto, H.

    1982-01-01

    Isolated perfused rat livers were used for investigating possible interactions between two simultaneously injected contrast media, and which technique, using parenteral application of cholegraphic media, is optimal. The results show that excretion of a parenteral contrast medium is reduced by giving an oral contrast medium at the same time. Simultaneous administration of two different contrast media therefore does not result in improved diagnostic information. The effect depends on the dose, and a sufficiently long interval should be observed between giving an oral and a parenteral contrast medium. A comparison of excretion values following injection of a bolus and prolonged infusion shows higher biliary contrast concentration and increased excretion after a single injection. Comparing only the period after the infusion, no difference was found between these two methods of administration. The single injection offers pharmacokinetic advantages, but an infusion is better tolerated and has fewer side effects. A rapid infusion of 10 to 15 minutes is therefore recommended as the optimal means of administration. (orig.) [de

  6. Systems and methods for separating particles utilizing engineered acoustic contrast capture particles

    Science.gov (United States)

    Kaduchak, Gregory; Ward, Michael D.

    2018-03-06

    An apparatus for separating particles from a medium includes a capillary defining a flow path therein that is in fluid communication with a medium source. The medium source includes engineered acoustic contrast capture particle having a predetermined acoustic contrast. The apparatus includes a vibration generator that is operable to produce at least one acoustic field within the flow path. The acoustic field produces a force potential minima for positive acoustic contrast particles and a force potential minima for negative acoustic contrast particles in the flow path and drives the engineered acoustic contrast capture particles to either the force potential minima for positive acoustic contrast particles or the force potential minima for negative acoustic contrast particles.

  7. Thermodynamics of non-ionic surfactant Triton X-100-cationic surfactants mixtures at the cloud point

    International Nuclear Information System (INIS)

    Batigoec, Cigdem; Akbas, Halide; Boz, Mesut

    2011-01-01

    Highlights: → Non-ionic surfactants are used as emulsifier and solubilizate in such as textile, detergent and cosmetic. → Non-ionic surfactants occur phase separation at temperature as named the cloud point in solution. → Dimeric surfactants have attracted increasing attention due to their superior surface activity. → The positive values of ΔG cp 0 indicate that the process proceeds nonspontaneous. - Abstract: This study investigates the effects of gemini and conventional cationic surfactants on the cloud point (CP) of the non-ionic surfactant Triton X-100 (TX-100) in aqueous solutions. Instead of visual observation, a spectrophotometer was used for measurement of the cloud point temperatures. The thermodynamic parameters of these mixtures were calculated at different cationic surfactant concentrations. The gemini surfactants of the alkanediyl-α-ω-bis (alkyldimethylammonium) dibromide type, on the one hand, with different alkyl groups containing m carbon atoms and an ethanediyl spacer, referred to as 'm-2-m' (m = 10, 12, and 16) and, on the other hand, with -C 16 alkyl groups and different spacers containing s carbon atoms, referred to as '16-s-16' (s = 6 and 10) were synthesized, purified and characterized. Additions of the cationic surfactants to the TX-100 solution increased the cloud point temperature of the TX-100 solution. It was accepted that the solubility of non-ionic surfactant containing polyoxyethylene (POE) hydrophilic chain was a maximum at the cloud point so that the thermodynamic parameters were calculated at this temperature. The results showed that the standard Gibbs free energy (ΔG cp 0 ), the enthalpy (ΔH cp 0 ) and the entropy (ΔS cp 0 ) of the clouding phenomenon were found positive in all cases. The standard free energy (ΔG cp 0 ) increased with increasing hydrophobic alkyl chain for both gemini and conventional cationic surfactants; however, it decreased with increasing surfactant concentration.

  8. Intravenous Contrast Medium Administration for Computed Tomography Scan in Emergency: A Possible Cause of Contrast-Induced Nephropathy

    International Nuclear Information System (INIS)

    Sonhaye, Lantam; Kolou, Bérésa; Tchaou, Mazamaesso; Amadou, Abdoulatif; Assih, Kouméabalo; N'Timon, Bidamin; Adambounou, Kokou; Agoda-Koussema, Lama; Adjenou, Komlavi; N'Dakena, Koffi

    2015-01-01

    The goal of this study was to assess risk for CIN after CT Scan during an emergency and to identify risk factors for the patient. Prospective review of all patients admitted to the emergency room (ER) of the Teaching Hospital of Lomé (Togo) during a 2-year period. CIN was defined as an increase in serum creatinine by 0.5 mg/dL from admission after undergoing CT Scan with intravenous contrast. A total of 620 patients underwent a CT Scan in the emergency room using intravenous contrast and 672 patients took the CT Scan without intravenous contrast. Out of the patients who received intravenous contrast for CT Scan, three percent of them developed CIN during their admission. Moreover, upon discharge no patient had continued renal impairment. No patient required dialysis during their admission. The multivariate analysis of all patients who had serial creatinine levels (including those who did not receive any contrast load) shows no increased risk for acute kidney injury associated intravenous contrast (odds ratio = 0.619, p value = 0.886); only diabetes remains independent risk factor of acute kidney injury (odds ratio = 6.26, p value = 0.031)

  9. Speckle contrast diffuse correlation tomography of complex turbid medium flow

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chong; Irwin, Daniel; Lin, Yu; Shang, Yu; He, Lian; Kong, Weikai; Yu, Guoqiang [Department of Biomedical Engineering, University of Kentucky, Lexington, Kentucky 40506 (United States); Luo, Jia [Department of Pharmacology and Nutritional Sciences, University of Kentucky, Lexington, Kentucky 40506 (United States)

    2015-07-15

    Purpose: Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckle contrast diffuse correlation tomography (scDCT), enables incorporation of complex optical property heterogeneities and sample boundaries. When combined with a reflectance-based design, this system facilitates a rapid segue into flow contrast imaging of larger, in vivo applications such as humans. Methods: A highly sensitive CCD camera was integrated into a reflectance-based optical system. Four long-coherence laser source positions were coupled to an optical switch for sequencing of tomographic data acquisition providing multiple projections through the sample. This system was investigated through incorporation of liquid and solid tissue-like phantoms exhibiting optical properties and flow characteristics typical of human tissues. Computer simulations were also performed for comparisons. A uniquely encountered smear correction algorithm was employed to correct point-source illumination contributions during image capture with the frame-transfer CCD and reflectance setup. Results: Measurements with scDCT on a homogeneous liquid phantom showed that speckle contrast-based deep flow indices were within 12% of those from standard DCT. Inclusion of a solid phantom submerged below the liquid phantom surface allowed for heterogeneity detection and validation. The heterogeneity was identified successfully by reconstructed 3D flow contrast tomography with scDCT. The heterogeneity center and dimensions and averaged relative flow (within 3%) and localization were in agreement with actuality and computer simulations, respectively. Conclusions: A custom cost-effective CCD-based reflectance 3D flow imaging system demonstrated rapid acquisition of dense boundary

  10. Characterization of a Biomimetic Mesophase Composed of Nonionic Surfactants and an Aqueous Solvent.

    Science.gov (United States)

    Adrien, V; Rayan, G; Reffay, M; Porcar, L; Maldonado, A; Ducruix, A; Urbach, W; Taulier, N

    2016-10-11

    We have investigated the physical and biomimetic properties of a sponge (L 3 ) phase composed of pentaethylene glycol monododecyl ether (C 12 E 5 ), a nonionic surfactant, an aqueous solvent, and a cosurfactant. The following cosurfactants, commonly used for solubilizing membrane proteins, were incorporated: n-octyl-β-d-glucopyranoside (β-OG), n-dodecyl-β-d-maltopyranoside (DDM), 4-cyclohexyl-1-butyl-β-d-maltoside (CYMAL-4), and 5-cyclohexyl-1-pentyl-β-d-maltoside (CYMAL-5). Partial phase diagrams of these systems were created. The L 3 phase was characterized using crossed polarizers, diffusion of a fluorescent probe by fluorescence recovery after pattern photobleaching (FRAPP), and freeze fracture electron microscopy (FFEM). By varying the hydration of the phase, we were able to tune the distance between adjacent bilayers. The characteristic distance (d b ) of the phase was obtained from small angle scattering (SAXS/SANS) as well as from FFEM, which yielded complementary d b values. These d b values were neither affected by the nature of the cosurfactant nor by the addition of membrane proteins. These findings illustrate that a biomimetic surfactant sponge phase can be created in the presence of several common membrane protein-solubilizing detergents, thus making it a versatile medium for membrane protein studies.

  11. The utility of gadoteric acid in contrast-enhanced MRI: a review

    Directory of Open Access Journals (Sweden)

    Tartaro A

    2015-02-01

    Full Text Available Armando Tartaro, Marica Tina Maccarone Department of Neuroscience, Imaging and Clinical Sciences, and Institute for Advanced Biomedical Technologies (ITAB, “G d’Annunzio” University, Chieti-Pescara, Italy Abstract: Gadoteric acid (Dotarem® is a macrocyclic, paramagnetic, gadolinium-based contrast agent. It is used in the magnetic resonance imaging (MRI of the brain, spine, and associated tissues. Particularly, it is able to detect and visualize areas with disruption of the blood–brain barrier and/or abnormal vascularity. Gadoteric acid has been also approved for MR angiography of supraaortic vessels, cardiac MR (to detect myocardial infarctions, as well as whole-body MRI including abdominal, renal, pelvic, breast, and osteoarticular diseases. Cyclic chelates are more stable compared to linear chelates, and ionic chelates are more stable compared to nonionic chelates. Linear chelates have a greater likelihood of releasing free Gd3+ compared to cyclic chelates. Non-ionic chelates are more likely, compared to ionic chelates, to release Gd3+ from their chelates. Gadoteric acid is a cyclic ionic chelate and has the greatest kinetic stability among gadolinium-based contrast agents. In patients with chronic reduced kidney function, the use of gadolinium-based contrast agents leads to acute kidney injury and dialysis. The risk of acute kidney injury may increase with increasing dose of the contrast agents. Therefore, it is recommended to administer the lowest dose necessary for adequate imaging. The dose reduction allows protection the patients form potential risk of nephrogenic systemic fibrosis, a systemic reaction that is probably due to unbound Gd3+ ions deposited in body tissues. The dose of gadoteric acid should not exceed 0.1 mmol/kg body weight. More than one dose should not be used during a scan. Because of the lack of information on repeated administration, Dotarem® injections should not be repeated unless the interval between

  12. Simple one step synthesis of nonionic dithiol surfactants and their self-assembling with silver nanoparticles: Characterization, surface properties, biological activity

    Energy Technology Data Exchange (ETDEWEB)

    Abd-Elaal, Ali A., E-mail: ali_ashour5@yahoo.com; Tawfik, Salah M.; Shaban, Samy M.

    2015-07-01

    Graphical abstract: - Highlights: • Nonionic dithiol surfactants were synthesized by simple one step esterification. • The surface activity of the synthesized dithiol surfactants showed high tendency toward adsorption and micellization. • The nanostructure of the synthesized nonionic dithiol surfactants with silver nanoparticles was prepared. • The silver nanoparticles enhanced the biological activity of the synthesized dithiol surfactants. - Abstract: Simple esterification of 2-mercaptoacetic acid and polyethylene glycol with different molecular weights was done to form the desired nonionic dithiol surfactants. The chemical structures of synthesized thiol surfactants were confirmed using FT-IR and {sup 1}H NMR spectra. The surface activity of the synthesized surfactants was determined by measurement of the surface tension at different temperatures. The surface activity measurements showed their high tendency towards adsorption and micellization. The thermodynamic parameters of micellization (ΔG{sub mic}, ΔH{sub mic} and ΔS{sub mic}) and adsorption (ΔG{sub ads}, ΔG{sub ads} and ΔS{sub ads}) showed their tendency toward adsorption at the interfaces and also micellization in the bulk of their solutions. The nanostructure of the synthesized nonionic dithiol surfactants with silver nanoparticles was prepared and investigated using UV and TEM techniques. Screening tests of the synthesized dithiol surfactants and their nanostructure with silver nanoparticles, against gram positive bacteria (Bacillus subtilis and Microccus luteus), gram negative bacteria (Escherichia coli and Bordatella pertussis) and fungi (Aspergillus niger and Candida albicans) showed that they are highly active biocides. The presence of silver nanoparticles enhancement the biological activities of the individual synthesized nonionic dithiol surfactants.

  13. Simple one step synthesis of nonionic dithiol surfactants and their self-assembling with silver nanoparticles: Characterization, surface properties, biological activity

    International Nuclear Information System (INIS)

    Abd-Elaal, Ali A.; Tawfik, Salah M.; Shaban, Samy M.

    2015-01-01

    Graphical abstract: - Highlights: • Nonionic dithiol surfactants were synthesized by simple one step esterification. • The surface activity of the synthesized dithiol surfactants showed high tendency toward adsorption and micellization. • The nanostructure of the synthesized nonionic dithiol surfactants with silver nanoparticles was prepared. • The silver nanoparticles enhanced the biological activity of the synthesized dithiol surfactants. - Abstract: Simple esterification of 2-mercaptoacetic acid and polyethylene glycol with different molecular weights was done to form the desired nonionic dithiol surfactants. The chemical structures of synthesized thiol surfactants were confirmed using FT-IR and 1 H NMR spectra. The surface activity of the synthesized surfactants was determined by measurement of the surface tension at different temperatures. The surface activity measurements showed their high tendency towards adsorption and micellization. The thermodynamic parameters of micellization (ΔG mic , ΔH mic and ΔS mic ) and adsorption (ΔG ads , ΔG ads and ΔS ads ) showed their tendency toward adsorption at the interfaces and also micellization in the bulk of their solutions. The nanostructure of the synthesized nonionic dithiol surfactants with silver nanoparticles was prepared and investigated using UV and TEM techniques. Screening tests of the synthesized dithiol surfactants and their nanostructure with silver nanoparticles, against gram positive bacteria (Bacillus subtilis and Microccus luteus), gram negative bacteria (Escherichia coli and Bordatella pertussis) and fungi (Aspergillus niger and Candida albicans) showed that they are highly active biocides. The presence of silver nanoparticles enhancement the biological activities of the individual synthesized nonionic dithiol surfactants

  14. [Biological effects of non-ionizing electromagnetic radiation].

    Science.gov (United States)

    Fedorowski, A; Steciwko, A

    1998-01-01

    Since the mid 1970's, when Adey discovered that extremely-low-frequency electromagnetic field (ELF EMF) may affect the calcium ions efflux from various cells, bioeffects of non-ionizing radiation (NIR) have become the subject of growing interest and numerous research projects. At present, the fact that NIR exerts both stimulatory and inhibitory effects on different physiological cellular parameters is rather unquestionable. At the same time, some epidemiological studies suggest that exposure to EMF is potentially harmful even if its intensity is very low. It has been proved that thermal factors are not responsible for these effects, therefore nowadays, they are called 'non-thermal effects'. Our paper deals with three different aspects of biological effects of non-ionizing radiation, bioelectromagnetism, electromagnetobiology and electromagnetic bioinformation. Firstly, we describe how EMF and photons can be produced within a living cell, how biological cycles are controlled, and what are the features of endogenous electromagnetic radiation. Secondly, we discuss various facets of external EMF interactions with living matter, focusing on extremely-low-frequencies, radio- and microwaves. Possible mechanisms of these interactions are also mentioned. Finally, we present a short overview of current theories which explain how electromagnetic couplings may control an open and dissipative structure, namely the living organism. The theory of electromagnetic bioinformation seems to explain how different physiological processes are triggered and controlled, as well as how long-range interactions may possibly occur within the complex biological system. The review points out that the presented research data must be assessed very carefully since its evaluation is crucial to set the proper limits of EMF exposure, both occupational and environmental. The study of biological effects of non-ioinizing radiation may also contribute to the development of new diagnostic and therapeutic

  15. Acute thyrotoxicosis secondary to destructive thyroiditis associated with cardiac catheterization contrast dye.

    Science.gov (United States)

    Calvi, Laura; Daniels, Gilbert H

    2011-04-01

    Thyrotoxicosis caused by destructive thyroiditis is self-limited and results from the subacute release of preformed thyroid hormone. Common etiologies include painful subacute thyroiditis and silent (painless) subacute thyroiditis (including postpartum thyroiditis, amiodarone-associated destructive thyroiditis, and lithium-associated thyroiditis). Thyrotoxicosis commonly evolves slowly over a matter of weeks. We report a unique case of severe thyrotoxicosis caused by acute- onset painful destructive thyroiditis in a patient who received large amounts of nonionic contrast dye Hexabrix® for cardiac catheterization. The results of thyroid function and physical examination were normal before the catheterization. The acute onset of severe thyroid pain, rapid increase in serum Free Thyroxine Index, and thyroglobulin concentrations with a triiodothyronine to free thyroxine index ratio of thyroiditis, likely related to direct toxicity from the iodinated contrast material. In light of the large number of patients who receive these contrast agents during cardiac catheterization, clinicians should be advised of this potentially serious complication, particularly in the setting of unstable cardiac disease.

  16. Influence of hyperosmotic agent (glycerol) in contrast enhancement

    International Nuclear Information System (INIS)

    Moriyama, Takashi; Suzuki, Shigeharu; Nakaoka, Tsutomu

    1981-01-01

    For getting a better contrast enhancement (CE) of computed tomography (CT) in brain tumors, we tried to increase the extravascular iodine concentration. A vailing ourselves of the period of returning water following intravenously administered glycerol, a drip injection of the contrast medium gave a better CE effect than the usual CE. In two benign gliomas, CE with glycerol was much better than CE without glycerol, and in two malignant gliomas and two metastatic tumors, CE with glycerol was better, but not so much better as with the benign tumors. In general, the CE effect in primary brain tumors showed a decreasing pattern, whereas in metastatic brain tumors the best time was 60 minutes after the injection of the contrast material (increasing and decreasing pattern), suggesting an increase in the extravascular iodine and a severe failure of the blood brain barrier. Two cystic malignant gliomas allowed the intravenously injected contrast medium to enter the cysts. It appears that the contrast medium passes through and/or is secreted from the wall of the cyst. (author)

  17. Potentials and limitations of low-concentration contrast medium (150 mg iodine/ml) in CT pulmonary angiography

    International Nuclear Information System (INIS)

    Radon, M.R.; Kaduthodil, M.J.; Jagdish, J.; Matthews, S.; Hill, C.; Bull, M.J.; Morcos, S.K.

    2011-01-01

    Aim: To assess the feasibility of producing diagnostic multidetector computed tomography (MDCT) pulmonary angiography with low iodine concentration contrast media (150 mg iodine/ml) in patients with suspected acute pulmonary embolism. Materials and methods: Ninety-five randomized patients underwent MDCT (64 row) pulmonary angiography with 100 ml iopromide either at low concentration (LC) of 150 mg iodine/ml (n = 45) or high concentration (HC) of 300 mg iodine/ml (n = 50), delivered at the rate of 5 ml/s via a power injector. Two experienced radiologists, blinded to the concentration used, subjectively assessed the diagnostic quality and confidence using a four-point scale [1 = poor (not diagnostic), 2 = satisfactory, 3 = good, 4 = excellent]. Attenuation values (in HU) were measured in the main proximal branches of the pulmonary arteries. Results: The median diagnostic quality score for both observers was 3.5 (interquartile range 3-4) in the HC group and 2.5 (interquartile range 1.5-3) in the LC group (p < 0.01). The median diagnostic confidence score for both observers was 4 (interquartile range 3-4) in the HC group and 3 (interquartile range 1.5-4) in the LC group (p < 0.01). Both observers rated examinations as diagnostic in 69% of cases in the LC group, compared with 96% of cases in the HC group. Good interobserver agreement was found in both groups (K value 0.72 in the LC group and 0.73 in the HC). Obesity, poor scan timing, and dilution by venous return of non-opacified blood were the main reasons for a reduction in diagnostic quality of examinations in the LC group. Conclusion: Despite a 50% reduction of contrast medium dose in comparison to the standard technique, 150 mg iodine/ml can produce diagnostic MDCT pulmonary angiogram studies in the absence of obesity or high cardiac output and hyper-dynamic pulmonary circulation. Reducing the dose of contrast media would minimize the risk of contrast nephropathy in patients at risk of this complication

  18. MR mammography: influence of menstrual cycle on the dynamic contrast enhancement of fibrocystic disease

    International Nuclear Information System (INIS)

    Rieber, A.; Nuessle, K.; Merkle, E.; Tomczak, R.; Brambs, H.J.; Kreienberg, R.

    1999-01-01

    Magnetic resonance mammography (MRM) provides data regarding the nature of tumours based on contrast medium dynamics; fibrocystic changes in the breast, however, may lead to false-positive results. This study investigated whether the contrast medium dynamics of fibrocystic changes are dependent on the menstrual cycle. Twenty-four patients with palpable lumps but normal mammographies and ultrasound studies were examined. The MRM technique was performed during the first and second part of the menstrual cycle using a FLASH 3D sequence, both native and at 1, 2, 3 and 8 min after intravenous application of 0.15 mmol/kg body weight of gadodiamide. The calculated time-intensity curves were evaluated based on the following criteria: early percentage of contrast medium uptake in relation to the native value; formation of a plateau phenomenon after the second minute; the point of maximal contrast medium uptake; and calculation of the contrast enhancing index. During the second half of the menstrual cycle, a generally greater contrast medium uptake was observed. Nevertheless, when further diagnostic criteria, such as continuous contrast medium increase as a function of time, were considered, there was no increased rate of false-positive findings. The phase of the menstrual cycle may affect the specificity of the examination, if only the quantitative contrast medium uptake and the percentage of contrast medium uptake in the first 2 min are considered. A control MRM during the other half of the cycle may then be indicated and additional diagnostic criteria may improve specificity. (orig.)

  19. MR mammography: influence of menstrual cycle on the dynamic contrast enhancement of fibrocystic disease

    Energy Technology Data Exchange (ETDEWEB)

    Rieber, A.; Nuessle, K.; Merkle, E.; Tomczak, R.; Brambs, H.J. [Ulm Univ. (Germany). Abt. Radiologie 1 (Roentgendiagnostik); Kreienberg, R. [Ulm Univ. (Germany). Dept. of Gynecology

    1999-08-01

    Magnetic resonance mammography (MRM) provides data regarding the nature of tumours based on contrast medium dynamics; fibrocystic changes in the breast, however, may lead to false-positive results. This study investigated whether the contrast medium dynamics of fibrocystic changes are dependent on the menstrual cycle. Twenty-four patients with palpable lumps but normal mammographies and ultrasound studies were examined. The MRM technique was performed during the first and second part of the menstrual cycle using a FLASH 3D sequence, both native and at 1, 2, 3 and 8 min after intravenous application of 0.15 mmol/kg body weight of gadodiamide. The calculated time-intensity curves were evaluated based on the following criteria: early percentage of contrast medium uptake in relation to the native value; formation of a plateau phenomenon after the second minute; the point of maximal contrast medium uptake; and calculation of the contrast enhancing index. During the second half of the menstrual cycle, a generally greater contrast medium uptake was observed. Nevertheless, when further diagnostic criteria, such as continuous contrast medium increase as a function of time, were considered, there was no increased rate of false-positive findings. The phase of the menstrual cycle may affect the specificity of the examination, if only the quantitative contrast medium uptake and the percentage of contrast medium uptake in the first 2 min are considered. A control MRM during the other half of the cycle may then be indicated and additional diagnostic criteria may improve specificity. (orig.) With 2 figs., 2 tabs., 24 refs.

  20. Gadolinium Use in Spine Pain Management Procedures for Patients with Contrast Allergies: Results in 527 Procedures

    International Nuclear Information System (INIS)

    Safriel, Yair; Ang, Roberto; Ali, Muhammed

    2008-01-01

    Introduction. To review the safety and efficacy of gadolinium in spine pain management procedures in patients at high risk for a contrast reaction and who are not suitable candidates for the use of standard non-ionic contrast. Methods. We reviewed records over a 61-month period of all image-guided spinal pain management procedures where patients had allergies making them unsuitable candidates for standard non-ionic contrast and where gadolinium was used to confirm needle tip placement prior to injection of medication. Results. Three hundred and four outpatients underwent 527 procedures. A spinal needle was used in all but 41 procedures. Gadolinium was visualized using portable C-arm fluoroscopy in vivo allowing for confirmation of needle tip location. The gadolinium dose ranged from 0.2 to 10 ml per level. The highest dose received by one patient was 15.83 ml intradiscally during a three-level discogram. Three hundred and one patients were discharged without complication or known delayed complications. One patient had documented intrathecal injection but without sequelae and 2 patients who underwent cervical procedures experienced seizures requiring admission to the intensive care unit. Both the latter patients were discharged without any further complications. Conclusion. Based on our experience we recommend using gadolinium judiciously for needle tip confirmation. We feel more confident using gadolinium in the lumbar spine and in cervical nerve blocks. Gadolinium should probably not be used as an injectate volume expander. The indications for gadolinium use in cervical needle-guided spine procedures are less clear and use of a blunt-tipped needle should be considered

  1. The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke

    International Nuclear Information System (INIS)

    Tijssen, M.P.M.; Stadler, A.A.R.; Zwam, W. van; Graaf, R. de; Postma, A.A.; Hofman, P.A.M.; Oostenbrugge, R.J. van; Klotz, E.; Wildberger, J.E.

    2014-01-01

    To assess the feasibility of dual energy computed tomography (DE-CT) in intra-arterially treated acute ischaemic stroke patients to discriminate between contrast extravasation and intracerebral haemorrhage. Thirty consecutive acute ischaemic stroke patients following intra-arterial treatment were examined with DE-CT. Simultaneous imaging at 80 kV and 140 kV was employed with calculation of mixed images. Virtual unenhanced non-contrast (VNC) images and iodine overlay maps (IOM) were calculated using a dedicated brain haemorrhage algorithm. Mixed images alone, as ''conventional CT'', and DE-CT interpretations were evaluated and compared with follow-up CT. Eight patients were excluded owing to a lack of follow-up or loss of data. Mixed images showed intracerebral hyperdense areas in 19/22 patients. Both haemorrhage and residual contrast material were present in 1/22. IOM suggested contrast extravasation in 18/22 patients; in 16/18 patients this was confirmed at follow-up. The positive predictive value (PPV) of mixed imaging alone was 25 %, with a negative predictive value (NPV) of 91 % and accuracy of 63 %. The PPV for detection of haemorrhage with DE-CT was 100 %, with an NPV of 89 % and accuracy improved to 89 %. Dual energy computed tomography improves accuracy and diagnostic confidence in early differentiation between intracranial haemorrhage and contrast medium extravasation in acute stroke patients following intra-arterial revascularisation. (orig.)

  2. The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Tijssen, M.P.M.; Stadler, A.A.R.; Zwam, W. van; Graaf, R. de; Postma, A.A. [Maastricht University Medical Centre, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Hofman, P.A.M. [Maastricht University Medical Centre, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Maastricht University, MhENS School for Mental Health and Neuroscience, Maastricht (Netherlands); Oostenbrugge, R.J. van [Maastricht University Medical Centre, Department of Neurology, P.O. Box 5800, Maastricht (Netherlands); Maastricht University, CARIM School for Cardiovascular Diseases, P.O. Box 616, Maastricht (Netherlands); Klotz, E. [Siemens Healthcare Sector, Computed Tomography, Forchheim (Germany); Wildberger, J.E. [Maastricht University Medical Centre, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Maastricht University, CARIM School for Cardiovascular Diseases, P.O. Box 616, Maastricht (Netherlands)

    2014-04-15

    To assess the feasibility of dual energy computed tomography (DE-CT) in intra-arterially treated acute ischaemic stroke patients to discriminate between contrast extravasation and intracerebral haemorrhage. Thirty consecutive acute ischaemic stroke patients following intra-arterial treatment were examined with DE-CT. Simultaneous imaging at 80 kV and 140 kV was employed with calculation of mixed images. Virtual unenhanced non-contrast (VNC) images and iodine overlay maps (IOM) were calculated using a dedicated brain haemorrhage algorithm. Mixed images alone, as ''conventional CT'', and DE-CT interpretations were evaluated and compared with follow-up CT. Eight patients were excluded owing to a lack of follow-up or loss of data. Mixed images showed intracerebral hyperdense areas in 19/22 patients. Both haemorrhage and residual contrast material were present in 1/22. IOM suggested contrast extravasation in 18/22 patients; in 16/18 patients this was confirmed at follow-up. The positive predictive value (PPV) of mixed imaging alone was 25 %, with a negative predictive value (NPV) of 91 % and accuracy of 63 %. The PPV for detection of haemorrhage with DE-CT was 100 %, with an NPV of 89 % and accuracy improved to 89 %. Dual energy computed tomography improves accuracy and diagnostic confidence in early differentiation between intracranial haemorrhage and contrast medium extravasation in acute stroke patients following intra-arterial revascularisation. (orig.)

  3. The study of the effects of ionizing and non-ionizing radiations on birth weight of newborns to exposed mothers

    OpenAIRE

    Mortazavi, S. M. J.; Shirazi, K. R.; Mortazavi, G.

    2013-01-01

    Objectives: Life evolved in an environment filled with a wide variety of ionizing and non-ionizing radiation. It was previously reported that medical exposures to pregnant women increases the risk of low birth weight. This study intends to investigate the relationship between exposure to ionizing and non-ionizing radiation and the risk of low birth weight. Materials and Methods: One thousand two hundred mothers with their first-term labor (vaginal or cesarean) whose newborns? history had been...

  4. Non-ionizing radiation measurements and protection. V. 1,2

    International Nuclear Information System (INIS)

    Cornelius, W.A.; Delpizzo, V.; Joyner, K.H.; Roy, C.R.; Wilkinson, F.J.

    1985-09-01

    The use of non-ionizing radiation (NIR) sources in the scientific, medical, industrial and domestic areas is becoming increasingly widespread. Concern has been expressed of the increased possibility of exposure of employees and of the public to NIR. Regulatory authorities have the role of ensuring that all organisations using NIR source keep the exposure of all persons below prescribed limits. The lecture notes draw together the basic information on NIR protection including essential quantities and units, biological interactions, protection standards, measurement techniques and personnel protection

  5. Quality of roentgenological visualization and tolerance of various intravenous cholegraphic contrast media

    International Nuclear Information System (INIS)

    Tischendorf, P.

    1980-01-01

    The recently introduced intravenous cholegraphic contrast media produce a greater diagnostic yield in radiological routine thanks to improved roentgenological contrasting. Whereas the percentage share of roentgenologically clearly assessable cases is about 75% when using Biligrafin, this percentage is much higher with the more recent contrast media, especially Biliscopin, namely, up to 88%. These new contrast media are also superior in respect of tolerance, since they produce fewer side effects. While side effects must be expected in about 28% of the cases when injecting Biligrafin, the side effect quota is about 10% only with Biliscopin or Endomirabil. If the contrast medium is infused instead of injected, the quota of side effect drops to 2.3% with Biliscopin or 3.9% with Endomirabil. Slight and medium side effects have definitely decreased with the more recent contrast media. The slower and more continually the contrast medium is administered, the fewer are the side effects observed; this becomes particularly noticeable in the case of long-term infusions. However, the likelihood of severe incidents caused by the contrast medium remains unchanged at about 1% of the examined patients, even with the more recently introduced contrast media. (orig.) [de

  6. Medium wave exposure characterisation using exposure quotients.

    Science.gov (United States)

    Paniagua, Jesús M; Rufo, Montaña; Jiménez, Antonio; Antolín, Alicia; Pinar, Iván

    2010-06-01

    One of the aspects considered in the International Commission on Non-Ionizing Radiation Protection guidelines is that, in situations of simultaneous exposure to fields of different frequencies, exposure quotients for thermal and electrical stimulation effects should be examined. The aim of the present work was to analyse the electromagnetic radiation levels and exposure quotients for exposure to multiple-frequency sources in the vicinity of medium wave radio broadcasting antennas. The measurements were made with a spectrum analyser and a monopole antenna. Kriging interpolation was used to prepare contour maps and to estimate the levels in the towns and villages of the zone. The results showed that the exposure quotient criterion based on electrical stimulation effects to be more stringent than those based on thermal effects or power density levels. Improvement of dosimetry evaluations requires the spectral components of the radiation to be quantified, followed by application of the criteria for exposure to multiple-frequency sources.

  7. Saphenous Venous Ablation with Hot Contrast in a Canine Model

    International Nuclear Information System (INIS)

    Prasad, Amit; Qian Zhong; Kirsch, David; Eissa, Marna; Narra, Pavan; Lopera, Jorge; Espinoza, Carmen G.; Castaneda, Wifrido

    2008-01-01

    Purpose. To determine the feasibility, efficacy, and safety of thermal ablation of the saphenous vein with hot contrast medium. Methods. Twelve saphenous veins of 6 dogs were percutaneously ablated with hot contrast medium. In all animals, ablation was performed in the vein of one leg, followed by ablation in the contralateral side 1 month later. An occlusion balloon catheter was placed in the infragenicular segment of the saphenous vein via a jugular access to prevent unwanted thermal effects on the non-target segment of the saphenous vein. After inflation of the balloon, 10 ml of hot contrast medium was injected under fluoroscopic control through a sheath placed in the saphenous vein above the ankle. A second 10 ml injection of hot contrast medium was made after 5 min in each vessel. Venographic follow-up of the ablated veins was performed at 1 month (n = 12) and 2 months (n = 6). Results. Follow-up venograms showed that all ablated venous segments were occluded at 1 month. In 6 veins which were followed up to 2 months, 4 (66%) remained occluded, 1 (16%) was partially patent, and the remaining vein (16%) was completely patent. In these latter 2 cases, an inadequate amount of hot contrast was delivered to the lumen due to a closed balloon catheter downstream which did not allow contrast to displace blood within the vessel. Discussion. Hot contrast medium thermal ablation of the saphenous vein appears feasible, safe, and effective in the canine model, provided an adequate amount of embolization agent is used

  8. Repeat survey of current practice regarding corticosteroid prophylaxis for patients at increased risk of adverse reaction to intravascular contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Radhakrishnan, S. [Department of Radiology, Wishaw General Hospital, Lanarkshire Acute Hospitals NHS Trust, 50, Netherton Street, Wishaw, Lanarkshire ML2 0DP (United Kingdom)]. E-mail: sureshradhakrish@hotmail.com; Manoharan, S. [Department of Radiology, Wishaw General Hospital, Lanarkshire Acute Hospitals NHS Trust, 50, Netherton Street, Wishaw, Lanarkshire ML2 0DP (United Kingdom); Fleet, M. [Department of Radiology, Wishaw General Hospital, Lanarkshire Acute Hospitals NHS Trust, 50, Netherton Street, Wishaw, Lanarkshire ML2 0DP (United Kingdom)

    2005-01-01

    AIM: To compare the findings of a survey undertaken by us in 2002 regarding steroid premedication given in radiology departments to reduce the risk of adverse reactions in patients at increased risk of intravascular contrast media reactions with a similar survey published in 1994 by R. Seymour et al. The high risk patients considered in our survey were patients with history of asthma, drug allergies, hay fever and eczema. MATERIALS AND METHODS: A total of 225 questionnaires were sent to the consultant in charge for audit for radiology departments from the list given by the Royal College of Radiologists. 175 of the 225 questionnaires were returned (response rate 77.8%) and of these 172 were analysed with respect to the type, dose and duration of steroids. RESULTS: Compared to the survey in 1994, it was found that the number of departments who use steroid cover for all category of risk factors had increased compared to previous survey (73.8% in 2002 versus 55.3% in 1994 (p=0.001). There is now almost universal use of non-ionic contrast 98.8% versus 82.4% in 1994 (p=0.001). There is no agreed policy among radiology departments for the need or the dose or duration of steroid cover. CONCLUSION: Despite the more widespread use of non-ionic contrast media, the use of steroid premedication has increased which is contrary to what is expected as the incidence of adverse reaction to non ionic media is less than ionic contrast media.

  9. Contrast media induced acute renal failure in diabetics

    International Nuclear Information System (INIS)

    Rambausek, M.

    1985-01-01

    Dehydration, preexisting renal insufficiency, multiple myeloma and insulin-dependent diabetes mellitus are known risk factors for a radiocontrast medium induced acute renal failure. In 90% of patients with insulin-dependent diabetes mellitus, renal insufficiency and proteinuria, a further detoriation of renal function can be expected after i.v. administration of radiocontrast medium. Recent concepts on the genesis of acute renal failure after radiocontrast medium in multiple myeloma emphasize the role of tubular blocade (tubular precipitation of myeloma protein with contrast medium). In insulin-dependent diabetic patients we found altered carbohydrate composition of urinary Tamm Horsfall Protein (THP), with increased glucose and diminished N-acetyl-neuraminicacid content. This was paralleled by a difference in an in-vitro system of coprecipitation where THP of diabetes triggered more pronounced calcium dependent coprecipitation of contrast medium and albumin. These in-vitro findings might be important for the explanation of the genesis of radiocontrast medium-induced acute renal failure in insulin-dependent diabetes mellitus. (orig.) [de

  10. Ionizing and non-ionizing radiation and the risk of childhood cancer-illustrated with domestic radon and radio frequency electromagnetic field exposure

    OpenAIRE

    Hauri, Dimitri

    2013-01-01

    Background Children are exposed to many different environmental factors, including exposure to low-dose ionizing radiation and to non-ionizing radiation. Low-dose ionizing radiation comprises anthropogenic modified radiation and natural ionizing radiation from cosmic rays from the atmosphere, terrestrial gamma radiation from radionuclides in rocks and soils and radiation from radon. Non-ionizing radiation comprises optical radiation and radiation from electromagnetic fields. The la...

  11. Can low-dose CT with iterative reconstruction reduce both the radiation dose and the amount of iodine contrast medium in a dynamic CT study of the liver?

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Hiroto; Okada, Masahiro; Hyodo, Tomoko; Hidaka, Syojiro; Kagawa, Yuki; Matsuki, Mitsuru; Tsurusaki, Masakatsu; Murakami, Takamichi, E-mail: murakami@med.kindai.ac.jp

    2014-04-15

    Purpose: To investigate whether low-dose dynamic CT of the liver with iterative reconstruction can reduce both the radiation dose and the amount of contrast medium. Materials and methods: This study was approved by our institutional review board. 113 patients were randomly assigned to one of two groups. Group A/group B (fifty-eight/fifty-five patients) underwent liver dynamic CT at 120/100 kV, with 0/40% adaptive statistical iterative reconstruction (ASIR), with a contrast dose of 600/480 mg I/kg, respectively. Radiation exposure was estimated based on the manufacturer's phantom data. The enhancement value of the hepatic parenchyma, vessels and the tumor-to-liver contrast of hepatocellular carcinomas (HCCs) were compared between two groups. Two readers independently assessed the CT images of the hepatic parenchyma and HCCs. Results: The mean CT dose indices: 6.38/4.04 mGy, the dose-length products: 194.54/124.57 mGy cm, for group A/group B. The mean enhancement value of the hepatic parenchyma and the tumor-to-liver contrast of HCCs with diameters greater than 1 cm in the post-contrast all phases did not differ significantly between two groups (P > 0.05). The enhancement values of vessels in group B were significantly higher than that in group A in the delayed phases (P < 0.05). Two reader's confidence levels for the hepatic parenchyma in the delayed phases and HCCs did not differ significantly between the groups (P > 0.05). Conclusions: Low-dose dynamic CT with ASIR can reduce both the radiation dose and the amount of contrast medium without image quality degradation, compared to conventional dynamic CT without ASIR.

  12. Tissue macrophage activation: a shared sign of exposure to ionizing and non-ionizing radiation

    International Nuclear Information System (INIS)

    Petrenyov, D.R.

    2012-01-01

    The features of oxidative metabolism of peritoneal macrophages were studied in rats exposed to ionizing and non-ionizing radiation. An increased RNS and ROS production reported in animals exposed to both source of radiation showing non-specific response of organism. (authors)

  13. 3D CT cerebral angiography technique using a 320-detector machine with a time–density curve and low contrast medium volume: Comparison with fixed time delay technique

    International Nuclear Information System (INIS)

    Das, K.; Biswas, S.; Roughley, S.; Bhojak, M.; Niven, S.

    2014-01-01

    Aim: To describe a cerebral computed tomography angiography (CTA) technique using a 320-detector CT machine and a small contrast medium volume (35 ml, 15 ml for test bolus). Also, to compare the quality of these images with that of the images acquired using a larger contrast medium volume (90 or 120 ml) and a fixed time delay (FTD) of 18 s using a 16-detector CT machine. Materials and methods: Cerebral CTA images were acquired using a 320-detector machine by synchronizing the scanning time with the time of peak enhancement as determined from the time–density curve (TDC) using a test bolus dose. The quality of CTA images acquired using this technique was compared with that obtained using a FTD of 18 s (by 16-detector CT), retrospectively. Average densities in four different intracranial arteries, overall opacification of arteries, and the degree of venous contamination were graded and compared. Results: Thirty-eight patients were scanned using the TDC technique and 40 patients using the FTD technique. The arterial densities achieved by the TDC technique were higher (significant for supraclinoid and basilar arteries, p < 0.05). The proportion of images deemed as having “good” arterial opacification was 95% for TDC and 90% for FTD. The degree of venous contamination was significantly higher in images produced by the FTD technique (p < 0.001%). Conclusion: Good diagnostic quality CTA images with significant reduction of venous contamination can be achieved with a low contrast medium dose using a 320-detector machine by coupling the time of data acquisition with the time of peak enhancement

  14. Low osmolar (non-ionic) contrast media versus high osmolar (ionic) contrast media in intravenous urography and enhanced computerized tomography: a cost-effectiveness analysis.

    Science.gov (United States)

    Wangsuphachart, S

    1991-12-01

    The cost-effectiveness of three alternative policies for the use of intravenous contrast media for urography and enhanced computerized tomography (CT) are analyzed. Alternative #1 is to use high osmolar contrast media (HOCM) in all patients, the historical policy. Alternative #2 is to replace it with low osmolar contrast media (LOCM) in all patients. Alternative #3 is to use LOCM only in the high risk patients. Data on the 6,242 patients who underwent intravenous urography and enhanced CT at the Department of Radiology, Chulalongkorn Hospital in 1989 were used. Both societal and hospital viewpoints were analyzed. The incremental cost-effectiveness (ICE) between #2 and #1 was 26,739 Baht (US$1,070) per healthy day saved (HDS), while the ICE between #3 and #1 was 12,057 Baht (US$482) per HDS. For fatal cases only, ICE between #2 and #1 was 35,111 Baht (US$1,404) per HDS, while the ICE between #3 and #1 was 18,266 Baht (US$731) per HDS. The incremental cost (IC) per patient was 2,341 Baht (US$94) and 681 Baht (US$27) respectively. For the hospital viewpoint the ICE between #2 and #1 was 13,744 (US$550) and between #3 and #1 was 6,127 Baht (US$245) per HDS. The IC per patient was 1,203 Baht (US$48) and 346 Baht (US$14), respectively. From the sensitivity analysis, #3 should be used if the LOCM price is reduced more than 75% (equal to 626 Baht or less) and more than 80% of the patients are able to pay for the contrast media.

  15. Non-ionizing and ionizing dosimetry in a space radiation environment with GaAs and SiC LEDs

    International Nuclear Information System (INIS)

    Houdayer, A.; Hinrichsen, P.F.; Barry, A.L.; Ng, A.C.; Carlone, C.; Simard, JF.

    1996-01-01

    This paper describes a dosimetry experiment that will be carried onboard the Russian MIR space station. The experiment will compare the ionizing and Non-ionizing Energy Loss (NEL) in semiconductors of the radiation encountered in space. The ionizing dose will be detected using ThermoLuminescent Dosimeter (TLD) whereas SiC and GaAs LEDs will be used to measure the nonionizing component. The tray will be mounted on the outside of the station for a minimum period of 4 months. The goal of the experiment is to determine the feasibility of using SiC and GaAs LEDs as NEL dosimeters in space. (author)

  16. Investigation of extractive microbial transformation in nonionic surfactant micelle aqueous solution using response surface methodology.

    Science.gov (United States)

    Xue, Yingying; Qian, Chen; Wang, Zhilong; Xu, Jian-He; Yang, Rude; Qi, Hanshi

    2010-01-01

    Extractive microbial transformation of L-phenylacetylcarbinol (L-PAC) in nonionic surfactant Triton X-100 micelle aqueous solution was investigated by response surface methodology. Based on the Box-Behnken design, a mathematical model was developed for the predication of mutual interactions between benzaldehyde, Triton X-100, and glucose on L-PAC production. It indicated that the negative or positive effect of nonionic surfactant strongly depended on the substrate concentration. The model predicted that the optimal concentration of benzaldehyde, Triton X-100, and glucose was 1.2 ml, 15 g, and 2.76 g per 100 ml, respectively. Under the optimal condition, the maximum L-PAC production was 27.6 mM, which was verified by a time course of extractive microbial transformation. A discrete fed-batch process for verification of cell activity was also presented.

  17. Semi-quantitative proteomics of mammalian cells upon short-term exposure to nonionizing electromagnetic fields

    NARCIS (Netherlands)

    Kuzniar, A. (Arnold); C. Laffeber; B. Eppink (Berina); K. Bezstarosti (Karel); D.H. Dekkers (Dick); H. Woelders (Henri); A.P.M. Zwamborn; J.A.A. Demmers (Jeroen); J.H.G. Lebbink (Joyce); R. Kanaar (Roland)

    2017-01-01

    textabstractThe potential effects of non-ionizing electromagnetic fields (EMFs), such as those emitted by power-lines (in extremely low frequency range), mobile cellular systems and wireless networking devices (in radio frequency range) on human health have been intensively researched and debated.

  18. Extravasation of radiographic contrast material and compartment syndrome in the hand: a case report

    Directory of Open Access Journals (Sweden)

    Torrededia Laura

    2011-02-01

    Full Text Available Abstract Radiocontrast agents are a type of medical contrast material used to improve the visibility of internal bodily structures in X-ray based imaging techniques such as computed tomography (CT or radiography. Radiocontrast agents are typically iodine or barium compounds. Extravasation of contrast is a possible complication of imaging studies performed with contrasts. Most extravasations cause minimal swelling or erythema, however, skin necrosis, ulceration and compartment syndrome may occur with extravasation of large volumes of contrast. A case report is presented in which significant extravasation of contrast was caused while injecting the contrast intravenously into the back of the hand of a 50 year old patient during computed tomography. The patient was undergoing chemotherapy. The patient developed a compartment syndrome and a fasciotomy was required. Treatment options are outlined and emphasis is made on prevention of this iatrogenic complication. Some of the preventive measures to avoid these complications include use of non-ionic contrast (low osmolarity, careful choice of the site of intravenous administration, and close monitoring of the patient during injection of contrast to minimize or prevent extravasation injuries. Clear information to patients and prompt recognition of the complication can allow for other non-surgical treatment options than the one required in this case.

  19. Comparison of neutral and positive enteral contrast media for MDCT enteroclysis

    International Nuclear Information System (INIS)

    Aiyappan, Senthil Kumar; Kalra, Naveen; Sandhu, Manavjit Singh; Kochhar, Rakesh; Wig, Jai Dev; Khandelwal, Niranjan

    2012-01-01

    Objective: To compare neutral and positive enteral contrast media for MDCT enteroclysis (MDCTE) in various small bowel diseases. Materials and methods: 40 patients with suspicion of small bowel diseases were divided randomly into two equal groups. In one group, water was used as neutral enteral contrast and in other group, 2% water soluble iodinated contrast was used as positive enteral contrast. All MDCTE were done on a 16-slice multidetector row CT unit. The findings of MDCTE were compared with the standards of reference. Results: There were 12 cases of abdominal tuberculosis (30%), 5 cases of bowel masses (12%), 4 cases of Crohn's disease (10%), 3 cases of small bowel adhesions (7%), 2 cases of midgut volvulus (5%), 2 cases of segmental enteritis (5%) and 12 of all cases (30%) were normal. There was no statistically significant difference between neutral and positive enteral contrast with regards to bowel distention, contrast reflux and evaluation of duodenum. Abnormal bowel wall enhancement was appreciated only with use of neutral enteral contrast (n = 12). Evaluation of ileocaecal junction was possible in all 20 patients (100%) with positive enteral contrast but in only 17 patients (85%) with neutral enteral contrast. Overall sensitivity and specificity of MDCTE with use of neutral contrast medium (100 and 88% respectively) was greater for evaluation of small bowel diseases, when compared to MDCTE using positive enteral contrast medium (92.8 and 83.3% respectively). Conclusions: Water is a good enteral contrast medium for MDCT enteroclysis examination and allows better evaluation of abnormal bowel wall enhancement. Ileocaecal junction evaluation is better with positive enteral contrast medium.

  20. Post double-contrast sigmoid flush: An adjuvant technique in imaging diverticular disease

    International Nuclear Information System (INIS)

    Lappas, J.C.; Maglinte, D.D.T.; Kopecky, K.K.; Cockerill, E.M.; Lehman, G.A.

    1987-01-01

    In a prospective study, the effect of a low-density contrast medium infusion was evaluated as an adjunct to high-density double-contrast medium sigmoid imaging. Following a double-contrast medium barium enema (DCBE), 52 consecutive patients with sigmoid diverticulosis received an additional 500-700-mL enema with either water or a 1.5%CT barium suspension. Rectosigmoid films were evaluated for luminal distention, visualization of the interhaustral space, definition of diverticula, and interpretation of polypoid defects. While double-contrast medium views were excellent in 21%, improvement in multiple factors by water or 1.5% barium flush resulted in improved sigmoid images in 65% and 73% of patients, respectively. Polyps may be confirmed and artifactual defects confidently excluded. Sigmoid flush, particularly with low-density barium, is a simple adjunct to DCBE that improves visualization of the diverticular sigmoid

  1. High-pitch dual-source CT coronary angiography with low volumes of contrast medium

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Knobloch, Gesine; Durmus, Tahir; Hamm, Bernd; Schwenke, Carsten; Huppertz, Alexander

    2014-01-01

    To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). One-hundred consecutive patients (body weight 65-85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m 2 ) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G 30 , 30 mL; G 40 , 40 mL; G 50 , 50 mL; G 60 , 60 mL; G 70 , 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G 30 to 478.2 and 571.8 HU in G 70 . Mean attenuation values were higher in groups with higher CM volumes (P 30 , G 40 , G 50 , G 60 and G 70 were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. (orig.)

  2. Digital subtraction angiography (DSA) of aortocoronary bypass grafts in the early postoperative phase with peripheral-venous contrast medium injection

    International Nuclear Information System (INIS)

    Tuengerthal, S.; Lang, J.; Donhoeffner, A.

    1985-01-01

    Using a fully digitalised subtraction unit, aortocoronary bypass grafts can be visualised in the early postoperative phase by means of peripheral venous contrast medium injection (57 out of a total of 60 cases). In more than one-half of the cases (31 out of a total of 60), it is possible to outline sharply the bypass grafts from the beginning to their entry into the bridged-over coronary artery, in such a manner that any loops, kinks, stenoses or reduced flow rates can be recognised. This examination is not considered to be an invasive one by the patient, and the cardiosurgeon can welcome it as a valuable additional means of controlling and assessing the results of surgery. (orig.) [de

  3. Sodium addition and/or oxygen saturation of iohexol during normal and reduced perfusion pressure

    International Nuclear Information System (INIS)

    Baath, L.

    1990-01-01

    The influence on contractile force (CF) and the propensity for ventricular fibrillation (VF) from infusing the non-ionic contrast medium iohexol during normal (75 cm H 2 O) and reduced perfusion pressure (35 cm H 2 O) were investigated in the isolated rabbit heart. Both during normal and reduced perfusion pressure iohexol (150 mg I/ml) with oxygen saturation caused a smaller reduction of CF than iohexol without oxygen. During reduced pressure iohexol with sodium addition (28 mM NaCl) caused less depression of CF than iohexol without sodium. The combination of sodium addition and oxygen saturation had the least influence on CF. Iohexol (350 mg I/ml) without sodium had a similar fibrillatory propensity during both normal and reduced pressure. Enriching iohexol with 28 mM NaCl decreased the risk of VF. The decrease was similar during both normal and reduced pressure. The risk of VF from oxygen saturation of iohexol (350 mg I/ml, without sodium) was similar during both normal and reduced pressure. It is concluded that a small addition of sodium and/or oxygen saturation of a non-ionic monomeric contrast medium have beneficial effects on the heart both during normal perfusion pressure and during ischemia. (orig.)

  4. Hypersensitivity to contrast media and dyes.

    Science.gov (United States)

    Brockow, Knut; Sánchez-Borges, Mario

    2014-08-01

    This article updates current knowledge on hypersensitivity reactions to diagnostic contrast media and dyes. After application of a single iodinated radiocontrast medium (RCM), gadolinium-based contrast medium, fluorescein, or a blue dye, a hypersensitivity reaction is not a common finding; however, because of the high and still increasing frequency of those procedures, patients who have experienced severe reactions are nevertheless frequently encountered in allergy departments. Evidence on allergologic testing and management is best for iodinated RCM, limited for blue dyes, and insufficient for fluorescein. Skin tests can be helpful in the diagnosis of patients with hypersensitivity reactions to these compounds. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Contrast induced nephropathy in patients undergoing intravenous (IV) contrast enhanced computed tomography (CECT) and the relationship with risk factors: a meta-analysis

    NARCIS (Netherlands)

    Moos, Shira I.; van Vemde, David N. H.; Stoker, Jaap; Bipat, Shandra

    2013-01-01

    To summarize the incidence of contrast-induced nephropathy (CIN) and associations between CIN incidence and risk factors in patients undergoing intravenous contrast-enhanced computed tomography (CECT) with low- or iso-osmolar iodinated contrast medium. This review is performed in accordance with the

  6. Small angle neutron scattering study of the gemini nonionic surfactant in heavy water solutions

    International Nuclear Information System (INIS)

    Rajewska, A

    2012-01-01

    The nonionic gemini surfactant α α'-[2,4,7,9-tetramethyl-5-decyne-4,7diyl]bis[ω hydroxyl-polyoxyethylene] (S-10) was investigated in heavy water solutions only for concentrations: 2.3%, 2.5%,3%, 3.4%, 4% and 5% at temperature 25 C with small angle neutron scattering (SANS) method. All of surfactants solutions were prepared using D 2 O (99.9% deuterated, Prikladnaia Chimia, St. Petersburg, Russia) as a solvent. The nonionic gemini surfactant S-10 was obtained from Air Products and Chemicals, Inc., and used without further purification. All SANS measurements were performed on V-4 SANS spectrometer at BENSC, Berlin (Germany). Neutrons were used in wavelength range of 0.02 - 4 nm - 1. For the measurements quartz cells of were used during experiment. Up to 14 such cells were placed in a holder. Results from experiment was calculated and evaluated with PCG 2.0 program from Graz University (Austria). In the investigated solutions two axis ellipsoidal micelles was observed.

  7. Separation and recycling of nanoparticles using cloud point extraction with non-ionic surfactant mixtures.

    Science.gov (United States)

    Nazar, Muhammad Faizan; Shah, Syed Sakhawat; Eastoe, Julian; Khan, Asad Muhammad; Shah, Afzal

    2011-11-15

    A viable cost-effective approach employing mixtures of non-ionic surfactants Triton X-114/Triton X-100 (TX-114/TX-100), and subsequent cloud point extraction (CPE), has been utilized to concentrate and recycle inorganic nanoparticles (NPs) in aqueous media. Gold Au- and palladium Pd-NPs have been pre-synthesized in aqueous phases and stabilized by sodium 2-mercaptoethanesulfonate (MES) ligands, then dispersed in aqueous non-ionic surfactant mixtures. Heating the NP-micellar systems induced cloud point phase separations, resulting in concentration of the NPs in lower phases after the transition. For the Au-NPs UV/vis absorption has been used to quantify the recovery and recycle efficiency after five repeated CPE cycles. Transmission electron microscopy (TEM) was used to investigate NP size, shape, and stability. The results showed that NPs are preserved after the recovery processes, but highlight a potential limitation, in that further particle growth can occur in the condensed phases. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Physical experiments on the utility of non-iodine-containing contrast media

    International Nuclear Information System (INIS)

    Kirschner, H.; Burmester, U.; Stringaris, K.; Jentsch, F.

    1979-01-01

    Because of the excellent ability of the CT scanner in analyzing absorption, the use of non-iodine-containing contrast media will be discussed. Experimental studies of the chemical elements with the atomic number Z = 1-83 with a scan tension of 120 kV were made to determine how many atoms of a given element are necessary to replace one iodine atom in an iodine-containing contrast medium, whereby the same contrast enhancement in the scan picture as with the iodine-containing contrast medium is produced. (orig.) 891 ORU/orig. 892 MB [de

  9. Organophilization of bentonite clays with non-ionic surfactants aiming their use in drilling fluids base oil

    International Nuclear Information System (INIS)

    Silva, I.A.; Costa, J.M.R.; Neves, G.A.; Ferreira, H.C.; Ferreira, H.S.

    2010-01-01

    The use of nonionic surfactants has been replacing the traditional ionic surfactants among others by its high potential for resistance to thermal degradation. This work aims at the development of organoclay by the addition of nonionic surfactants for use in drilling fluids for oil wells based oil. The bentonite clay was organophilized and then characterized by X-ray diffraction and swelling Foster, seeking the most appropriate choice of surfactant to liquid organic dispersing media: ester, diesel and paraffin. With the obtained dispersions were measured apparent viscosities and plastic. The results showed that incorporation of surfactants used in the clay interlayer spacing increased significantly and that the dispersions showed rheological properties within the specifications of PETROBRAS, for the use of organophilic clays in drilling fluids in a non-aqueous base. (author)

  10. Methodical assessment of all non-ionizing radiation sources that can provide a relevant contribution to public exposure. Final report

    International Nuclear Information System (INIS)

    Bornkessel, Christian; Schubert, Markus; Wuschek, Matthias; Brueggemeyer, Hauke; Weiskopf, Daniela

    2011-01-01

    The aim of the research project was to systematically identify artificial sources on non-ionizing radiation (electric, magnetic or electromagnetic fields in a frequency range from 0 Hz to 300 GHz, as well optical radiation in a wavelength range from 100 nm to 1 mm), that have relevant contribution to public exposure. The report includes the following chapters: (1) Concept for the relevance assessment for non-ionizing radiation sources; (2) concept for the systematic identification of sources from establishes technologies; (3) concept for the systematic identification of sources from new or foreseeable technologies; (4)overview of relevant radiation sources.

  11. Iodinated contrast media induce neutrophil apoptosis through a mitochondrial and caspase mediated pathway.

    LENUS (Irish Health Repository)

    Fanning, N F

    2012-02-03

    Iodinated contrast media (ICM) can induce apoptosis (programmed cell death) in renal, myocardial and endothelial cells. Following intravascular injection, circulating immune cells are exposed to high concentrations of ICM. As neutrophils constitutively undergo apoptosis we hypothesized that ICM may adversely affect neutrophil survival. Our aim was to investigate the effect of ICM on neutrophil apoptosis. Neutrophils were isolated from healthy subjects and cultured in vitro with ionic (diatrizoate and ioxaglate) and non-ionic (iohexol and iotrolan) ICM. The effect of ICM on neutrophil apoptosis in both unstimulated and lipopolysaccharide-stimulated neutrophils was determined by annexin V flow cytometry. The influence of physicochemical properties of the different ICM on apoptosis of neutrophils was also studied. We further investigated the effects of ICM on key intracellular signal pathways, including p38 mitogen-activated protein kinase (MAPK) by Western blotting, and mitochondrial depolarization and caspase activity by flow cytometry. Isoiodine concentrations (20 mg ml(-1)) of ionic (diatrizoate 69.6+\\/-2.9%; ioxaglate 58.9+\\/-2.0%) and non-ionic (iohexol 57.3+\\/-2.9%; iotrolan 57.1+\\/-2.6%) ICM significantly induced neutrophil apoptosis over control levels (47.7+\\/-1.4%). The apoptotic effect of ICM was influenced by their chemical structure, with ionic ICM having a more significant (p<0.01) apoptotic effect than non-ionic ICM (p<0.05). Furthermore, ICM reversed the anti-apoptotic effect of lipopolysaccharide (1000 ng ml(-1)) treated neutrophils to control levels (23.0+\\/-3.5% to 61.2+\\/-5.3%; n=4; p<0.05). These agents induce apoptosis through a p38 MAPK independent pathway that results in mitochondrial depolarization, and is dependent on caspase activation. As neutrophils play a central role in host response to infection and injury, ICM, through induction of neutrophil apoptosis, could have a significant deleterious effect on host immune defence and

  12. Myths and misconceptions concerning contrast media-induced anaphylaxis: a narrative review.

    Science.gov (United States)

    Böhm, Ingrid; Morelli, John; Nairz, Knud; Silva Hasembank Keller, Patricia; Heverhagen, Johannes T

    2017-03-01

    Contrast-enhanced radiological examinations are an increasingly important diagnostic tool in modern medicine. All approved and available contrast media (iodinated and gadolinium-based) are safe compounds that are well-tolerated by most patients. However, a small percentage of patients exhibit contrast medium-induced adverse drug reactions that are dose-dependent and predictable (type A) or an even smaller cohort experience so-called type B (dose-independent, non-predictable). To increase patients' safety, recommendations/guidelines have been put forth in the literature and advice passed down informally by radiologists in practice to ensure contrast media safety. Through these, both reasonable suggestions as well as misinterpretations and myths (such as the misleading terms "allergy-like" reactions, and "iodine-allergy", the wrong assumption that the initial contact to a contrast medium could not induce an allergy, the estimation that an anti-allergy premedication could suppress all possible adverse reactions, and interleukin-2 as a risk/trigger for contrast medium adverse events) have arisen. Since the latter are not only unhelpful but also potentially reduce patients' safety, such myths and misconceptions are the focus of this review.

  13. Aspiration of Barium Contrast

    OpenAIRE

    Fuentes Santos, Cristina; Steen, Bárbara

    2014-01-01

    The aspiration of barium contrast is a rare complication that may occur during studies of the digestive tract. Barium is an inert material that can cause anywhere from an asymptomatic mechanical obstruction to serious symptoms of respiratory distress that can result in patient death. We present the case of a 79-year-old male patient in whom we observed the presence of contrast medium residue in the lung parenchyma as an incidental finding during hospitalization. When the patient’s medical fil...

  14. Use of postmortem coronary computed tomography angiography with water-insoluble contrast medium to detect stenosis of the left anterior descending artery in a case of sudden death.

    Science.gov (United States)

    Takahashi, Yoichiro; Sano, Rie; Takahashi, Keiko; Kominato, Yoshihiko; Takei, Hiroyuki; Kobayashi, Susumu; Shimada, Takehiro; Tokue, Hiroyuki; Awata, Sachiko; Hirasawa, Satoshi

    2016-03-01

    A 40-year-old man was found dead on a sidewalk in an expressway parking area one hour after he had entered the area on a motorcycle. A medicolegal autopsy was performed to reveal the cause of this sudden and unexpected death. Postmortem coronary CT angiography after introduction of 5% gelatin-barium emulsion as a radiopaque contrast medium into the heart demonstrated a significant arterial luminal filling defect in the left anterior descending (LAD) coronary artery. Macroscopic and microscopic examinations revealed that a thrombus had become deposited on ruptured plaque within the LAD artery, and that a small amount of the contrast medium was present between the thrombus and the vessel endothelium. These histological findings were consistent with incomplete occlusion of the LAD artery in the 3D reconstructed image. The cause of death in this case was definitively determined to be ischemic heart disease. Postmortem angiography played a role in screening of a vascular lesion that was subsequently verified by histology to have been responsible for sudden and unexpected death. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Visualization of endolymphatic hydrops in meniere's disease after single-dose intravenous gadolinium-based contrast medium. Timing of optimal enhancement

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Yamazaki, Masahiro; Kawai, Hisashi; Bokura, Kiminori; Sone, Michihiko; Nakashima, Tsutomu

    2012-01-01

    Visualization of endolymphatic hydrops (EH) in patients with Meniere's disease (MD) is now possible by heavily T 2 -weighted 3-dimensional fluid-attenuated inversion recovery (h T 2 W-3D-FLAIR) obtained 4 hours after intravenous (IV) administration of single dose gadolinium-based contrast medium (GBCM). Although maximum enhancement has been reported 4 hours after contrast administration in healthy volunteers, the timing of optimal enhancement in patients with MD is not reported. We investigated if that optimal timing is earlier or later than 4 hours. We evaluated 10 consecutive patients with suspected MD whom we randomly divided into 2 groups. We obtained h T 2 W-3D-FLAIR before GBCM administration and 10 min, 3.5 hours, and 4 hours after GBCM administration in Group A and before and 10 min, 4 hours, and 4.5 hours after GBCM administration in Group B. We compared signal intensity ratio (SIR) values of the perilymph and pons between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B and evaluated grades of EH at 3.5 and 4 hours in Group A and at 4 and 4.5 hours in Group B. SIR values did not differ significantly between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B. However, SIR values at 4 hours were significantly higher in Group A than Group B. Grades of EH agreed between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B. The optimal timing of contrast enhancement in patients with suspected MD remains unclear, but evaluation of EH may be possible from 3.5 to 4.5 hours after contrast administration. (author)

  16. Preliminary Testing For Anionic, Cationic and Non-ionic

    Directory of Open Access Journals (Sweden)

    Bokic, Lj.

    2007-11-01

    Full Text Available Detergents present a major environmental problem due to large quantities of surfactants released from laundries. For this reason, it is important to apply an appropriate analytical method for their determination. In this work, we propose two simple, fast and inexpensive analytical methods for anionic, cationic and non-ionic surfactant determination: thin layer chromatography (TLC separation for qualitative screening and quantitative potentiometric determination with ion-selective electrodes. These methods have been chosen because of their many advantages: rapidity, ease of operation, low cost of analysis and a wide variety of TLC application possibilities. The advantage of potentiometric titration is its very high degree of automation and very low detection limits obtained with different ion-selective electrodes applied for different surfactants.

  17. Contrast detail phantom for SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Cabrejas, M.L. de; Arashiro, J G; Giannone, C. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Camuyrano, M; Nohara, G [Universidad de Buenos Aires, Buenos Aires (Argentina). Facultad Ciencias Exactas

    1996-06-01

    A new low variable contrast phantom for single photon emission computed tomography (SPECT) was constructed, tested and compared with other existing phantoms. It contains simulated cylindrical lesions of four different diameters (D{sub i}), embedded in a cylindrical scattering medium and a uniform section to evaluate tomographic uniformity. The concentration of tracer in the simulated lesions and the scattering medium (background) can be varied to simulate hot and cold lesions. Different applications of the phantom were tested, including determination of the minimum object contrast (OCm) necessary to detect lesions as a function of lesion size, lesion type (hot or cold) and acquisition and processing protocols by visual inspection. This parameter allows categorization of instruments comparing an `image quality index` (IQI). Preliminary comparison with the Britten contrast processing method showed that the detectable OCm was of the same order of magnitude, but the presented device seems more suitable for training and intercomparison purposes. The constructed phantom, of simple design, has proved to be useful for acquisition and processing condition evaluation, OCm estimation and external quality control. (author). 11 refs, 4 figs.

  18. Iotrolan versus Iopamidol

    International Nuclear Information System (INIS)

    Maier, B.; Gerber, U.; Koenig, M.; Stetter, G.

    1992-01-01

    Within the frame work of lumbal myelography, 158 patients were entired in a double-blind study in order to test a dimeric contrast medium (iotrolan) against a monomeric one (iopamidol), both of them non-ionic. A three-step scheme was applied to evaluate the X-ray pictures with respect ot contrast quality. Particular attention was paid to the visibility of details, i.e. the nerve root and its course, as well as to its how well it could be distinguished in the nerve root sheath. On the basis of a high level of significance (P [de

  19. The study of the effects of ionizing and non-ionizing radiations on birth weight of newborns to exposed mothers.

    Science.gov (United States)

    Mortazavi, S M J; Shirazi, K R; Mortazavi, G

    2013-01-01

    Life evolved in an environment filled with a wide variety of ionizing and non-ionizing radiation. It was previously reported that medical exposures to pregnant women increases the risk of low birth weight. This study intends to investigate the relationship between exposure to ionizing and non-ionizing radiation and the risk of low birth weight. One thousand two hundred mothers with their first-term labor (vaginal or cesarean) whose newborns' history had been registered in neonates' screening program in Shiraz were interviewed and surveyed. Data collection was performed by the assessment of mother's history of radiography before and during pregnancy, physical examination of the mother for height and weight and weighing and examining the newborn for any diagnosis of disease and anomalies. There were no statistical significant differences between the mean weight of newborns whose mothers had been exposed to some common sources of ionizing and non-ionizing radiations such as dental or non dental radiographies, mobile phone, cordless phone and cathode ray tube (CRT) and those of non-exposed mothers. The findings of this study cast doubt on previous reports, which indicated that exposure to ionizing radiation during pregnancy increased the risk of low birth weight.

  20. Effects of age and brightness contrast on perception of the Wundt-Hering illusion.

    Science.gov (United States)

    Astor-Stetson, E; Purnell, T G

    1990-10-01

    Susceptibility to the Wundt-Hering illusion was studied as a function of age and contrast. Preschoolers, third-graders and college students were shown light-grey, medium-grey, and black Wundt-Hering figures on white ground. Pre-schoolers were most susceptible to the illusion, differing from third graders in the medium and high contrast conditions and from college students in all contrast conditions. Low contrast figures resulted in significantly less distortion than did high contrast figures for the preschoolers. The significant interaction of age and contrast effects highlights the importance of a developmental approach to the study of illusions.

  1. MRI cisternography with gadolinium-containing contrast medium: its role, advantages and limitations in the investigation of rhinorrhoea.

    Science.gov (United States)

    Aydin, K; Guven, K; Sencer, S; Jinkins, J R; Minareci, O

    2004-01-01

    Our purpose was to evaluate the utility of intrathecal gadopentetate dimeglumine -enhanced magnetic resonance cisternography (GdMRC). We injected 0.5 ml contrast medium into the subarachnoid space via lumbar puncture in 20 patients with suspected cerebrospinal fluid (CSF) rhinorrhoea. MRC showed CSF leakage in 14 patients with rhinorrhoea at the time of the examination, into the ethmoid air cells in nine, the sphenoid sinus in three and the frontal sinus in two cases. In 12 of these the site leakage was confirmed during surgical repair of the fistula. No leakage was observed in four patients with intermittent rhinorrhoea, not present at the time of the examination. GdMRC showed leakage in two patients with negative CT cisternography. GdMRC may prove better than CT cisternography, especially with slow CSF flow. We also showed low-dose GdMRC to be a feasible and relative safe way of confirming the presence of and localising active CSF leaks prior to surgical repair.

  2. MRI cisternography with gadolinium-containing contrast medium: its role, advantages and limitations in the investigation of rhinorrhoea

    International Nuclear Information System (INIS)

    Aydin, K.; Guven, K.; Sencer, S.; Minareci, O.; Jinkins, J.R.

    2004-01-01

    Our purpose was to evaluate the utility of intrathecal gadopentetate dimeglumine -enhanced magnetic resonance cisternography (GdMRC). We injected 0.5 ml contrast medium into the subarachnoid space via lumbar puncture in 20 patients with suspected cerebrospinal fluid (CSF) rhinorrhoea. MRC showed CSF leakage in 14 patients with rhinorrhoea at the time of the examination, into the ethmoid air cells in nine, the sphenoid sinus in three and the frontal sinus in two cases. In 12 of these the site leakage was confirmed during surgical repair of the fistula. No leakage was observed in four patients with intermittent rhinorrhoea, not present at the time of the examination. GdMRC showed leakage in two patients with negative CT cisternography. GdMRC may prove better than CT cisternography, especially with slow CSF flow. We also showed low-dose GdMRC to be a feasible and relative safe way of confirming the presence of and localising active CSF leaks prior to surgical repair. (orig.)

  3. RECYCLING A NONIONIC AQUEOUS-BASED METAL-CLEANING SOLUTION WITH A CERAMIC MEMBRANE: PILOT SCALE EVALUATION

    Science.gov (United States)

    The effectiveness of a zirconium dioxide (ZrO2) membrane filter was evaluated for recycling a nonionic aqueous metal cleaning bath under real-world conditions. The pilot-scale study consisted of four 7- to 16-day filtration runs, each processed a portion of the cleaning bath duri...

  4. Novel designed polyoxyethylene nonionic surfactant with improved safety and efficiency for anticancer drug delivery

    Directory of Open Access Journals (Sweden)

    Li C

    2014-04-01

    Full Text Available Chang Li,1 Chunmeng Sun,1 Shasha Li,1 Peng Han,2 Huimin Sun,3 Ammar Ouahab,1 Yan Shen,1 Yourui Xu,1 Yerong Xiong,1 Jiasheng Tu11State Key Laboratory of Natural Medicines, Department of Pharmaceutics, China Pharmaceutical University, Nanjing, 2Chinese Pharmacopoeia Commission, Beijing, 3National Institute for Food and Drug Control, Beijing, People's Republic of ChinaAbstract: In order to limit the adverse reactions caused by polysorbate 80 in Taxotere®, a widely used formulation of docetaxel, a safe and effective nanocarrier for this drug has been developed based on micelles formed by a new class of well-defined polyoxyethylene sorbitol oleate (PSO with sorbitol as the matrix in aqueous solution. The physicochemical properties of the amphiphilic surfactant and the resulting micelles can be easily fine-tuned by the homogeneous sorbitol matrix and pure oleic acid. Composition, critical micelle concentration, and entrapment efficiency were investigated by ultraviolet visible spectroscopy, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, fluorospectrophotometry, and high-performance liquid chromatography. In vitro and in vivo evaluation revealed that PSO had exceptionally low hemolysis and histamine release rates compared with commercial polysorbate 80. Moreover, the tumor targeting delivery of PSO was investigated by in vivo imaging in S180 tumor-bearing mice. The results suggest that this novel delivery system, PSO, provides an acceptable alternative to polysorbate 80 for delivery of docetaxel. Further, due to the hypoallergenic nature of PSO, the mechanism of pseudoallergy caused by the polyoxyethylene nonionic surfactant was investigated. Based on in vitro cell analysis, it was assumed that the initial contact of polyoxyethylene nonionic surfactant with mast cells provoked pseudoallergy via polyamine receptor-mediated endocytosis.Keywords: polyoxyethylene nonionic surfactant, sorbitol, isosorbide, pseudoallergy

  5. Hydrophilic polymer-coated microcatheter-guide wire system for superselective angiographic procedures

    International Nuclear Information System (INIS)

    Kobayashi, Hisashi; Hiraki, Yoshiyuki; Nishimoto, Hidetou; Miyazono, Nobuaki; Satake, Mitsuo; Shinohara, Shinji

    1988-01-01

    A hydrophilic polymer-coated microcatheter-guide wire device has been newly developed for superselective angiography and interventional procedures. The injection rate of this microcatheter was estimated at 2.0 ml/sec. on the maximum pressure of 300 psi when used a non-ionic low osmolar contrast medium, Iopamidol 300. In two of three cases this catheter could make easy insertion into the peripheral branches of the right hepatic artery which were approximately 1 mm in vascular diameter. (author)

  6. Managing the risk associated with use of contrast media for computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Stacul, Fulvio [Department of Radiology, University of Trieste, Cattinara Hospital, Strada di Fiume, 447, 34149 Trieste (Italy)]. E-mail: fulvio.stacul@aots.sanita.fvg.it

    2007-05-15

    Contrast agents are widely used in patients undergoing diagnostic and therapeutic imaging procedures. In recent years, there has been a significant increase in the use of iodinated contrast media (CM) due to the growing number of computed tomography (CT) procedures. Although contrast agents are generally well-tolerated, some patient subsets are at an increased risk of complications from CM. Patients at risk include those with a history of adverse reactions to CM, asthma or severe allergies, impaired renal function, older age, dehydration, congestive heart failure, or concurrent use of some drugs. Although the incidence of CM-associated complications cannot be eliminated, the chances of developing severe adverse reactions can be reduced by incorporating a number of management strategies into clinical practice. Patients at risk for acute adverse reactions can undergo pre-medication with corticosteroids, eventually associated with anti-histamines, although opinion is divided whether this prophylaxis should be used with non-ionic CM. Patients who have been identified as at risk for contrast-induced nephropathy (CIN) should be well-hydrated and have nephrotoxic medications withdrawn prior to CM exposure. Contrast dose should be decreased, as the risk of developing CIN is dose-dependent. For patients with pre-existing renal insufficiency, use of low-osmolar or iso-osmolar CM is preferable to use of high-osmolar CM. Simple strategies for preventing the risk of adverse reactions are reviewed.

  7. Managing the risk associated with use of contrast media for computed tomography

    International Nuclear Information System (INIS)

    Stacul, Fulvio

    2007-01-01

    Contrast agents are widely used in patients undergoing diagnostic and therapeutic imaging procedures. In recent years, there has been a significant increase in the use of iodinated contrast media (CM) due to the growing number of computed tomography (CT) procedures. Although contrast agents are generally well-tolerated, some patient subsets are at an increased risk of complications from CM. Patients at risk include those with a history of adverse reactions to CM, asthma or severe allergies, impaired renal function, older age, dehydration, congestive heart failure, or concurrent use of some drugs. Although the incidence of CM-associated complications cannot be eliminated, the chances of developing severe adverse reactions can be reduced by incorporating a number of management strategies into clinical practice. Patients at risk for acute adverse reactions can undergo pre-medication with corticosteroids, eventually associated with anti-histamines, although opinion is divided whether this prophylaxis should be used with non-ionic CM. Patients who have been identified as at risk for contrast-induced nephropathy (CIN) should be well-hydrated and have nephrotoxic medications withdrawn prior to CM exposure. Contrast dose should be decreased, as the risk of developing CIN is dose-dependent. For patients with pre-existing renal insufficiency, use of low-osmolar or iso-osmolar CM is preferable to use of high-osmolar CM. Simple strategies for preventing the risk of adverse reactions are reviewed

  8. Non-ionizing radiation: an occupational apathy

    International Nuclear Information System (INIS)

    Mohd Yusof Mohd Ali

    2000-01-01

    Non-ionizing radiation, NIR, is widely used in various modern applications to the extent that its presence is common in some work places. However, due to inability of human beings to detect its presence make the radiation 'invisible' to the workers most of the time. Of late it is known that the radiation can be hazardous to human health if the exposure received is excessively high. Such proven health effects has led international organizations, such as, IRPA establishing standard guidelines and maximum permissible limits to control its exposure. Recent studies reveal that some work places do indicate the presence of the radiation at levels far exceeding the IRPA recommended limits. It is, therefore, the objective of this paper to highlight such hazardous situations, magnitude of the hazards involved and ways and means how to overcome the hazard so that workers can take necessary precaution and action to minimize the health risk associated with the hazard. However, due to time and space constraint, only five types of the NIR are elaborated in this paper, namely ELF, RF and microwave, UV, IR and laser

  9. HPLC/ESI-quadrupole ion trap mass spectrometry for characterization and direct quantification of amphoteric and nonionic surfactants in aqueous samples

    Science.gov (United States)

    Levine, Lanfang H.; Garland, Jay L.; Johnson, Jodie V.

    2002-01-01

    An amphoteric (cocamidopropylbetaine, CAPB) and a nonionic (alcohol polyethoxylate, AE) surfactant were characterized by electrospray ionization quadrupole ion trap mass spectrometry (ESI-MS) as to their homologue distribution and ionization/fragmentation chemistry. Quantitative methods involving reversed-phase gradient HPLC and (+)ESI-MSn were developed to directly determine these surfactants in hydroponic plant growth medium that received simulated graywater. The predominant homologues, 12 C alkyl CAPB and 9 EO AE, were monitored to represent the total amount of the respective surfactants. The methods demonstrated dynamic linear ranges of 0.5-250 ng (r2 > 0.996) for CAPB and 8-560 ng (r2 > 0.998) for AE homologue mixture, corresponding to minimum quantification limits of 25 ppb CAPB and 0.4 ppm AE with 20-microL injections. This translated into an even lower limit for individual components due to the polydispersive nature of the surfactants. The procedure was successfully employed for the assessment of CAPB and AE biodegradation in a hydroponic plant growth system used as a graywater bioreactor.

  10. Medical uses non-ionizing radiation; Uso medicos de radiaciones no ionizantes

    Energy Technology Data Exchange (ETDEWEB)

    Ubeda Maeso, A.; Trillo Ruiz, M. A.

    2016-08-01

    This article reviews various clinical applications of non-ionizing radiation, focusing on the Hz-GHz frequency range. Depending on the signal characteristics, the applications cover several therapeutic areas, including osteology and traumatology, tissue regeneration, physiotherapy, chronic pain treatment, neurology, cardiology, urology and oncology. Electromagnetic therapies have proved simple, safe, low cost, devoid of side effects and able to treat the underlying pathology rather than simply alleviate the symptoms. Therefore, it is predictable that these therapies will have as serious impact on public health and associated costs. (Author)

  11. A finite-difference contrast source inversion method

    International Nuclear Information System (INIS)

    Abubakar, A; Hu, W; Habashy, T M; Van den Berg, P M

    2008-01-01

    We present a contrast source inversion (CSI) algorithm using a finite-difference (FD) approach as its backbone for reconstructing the unknown material properties of inhomogeneous objects embedded in a known inhomogeneous background medium. Unlike the CSI method using the integral equation (IE) approach, the FD-CSI method can readily employ an arbitrary inhomogeneous medium as its background. The ability to use an inhomogeneous background medium has made this algorithm very suitable to be used in through-wall imaging and time-lapse inversion applications. Similar to the IE-CSI algorithm the unknown contrast sources and contrast function are updated alternately to reconstruct the unknown objects without requiring the solution of the full forward problem at each iteration step in the optimization process. The FD solver is formulated in the frequency domain and it is equipped with a perfectly matched layer (PML) absorbing boundary condition. The FD operator used in the FD-CSI method is only dependent on the background medium and the frequency of operation, thus it does not change throughout the inversion process. Therefore, at least for the two-dimensional (2D) configurations, where the size of the stiffness matrix is manageable, the FD stiffness matrix can be inverted using a non-iterative inversion matrix approach such as a Gauss elimination method for the sparse matrix. In this case, an LU decomposition needs to be done only once and can then be reused for multiple source positions and in successive iterations of the inversion. Numerical experiments show that this FD-CSI algorithm has an excellent performance for inverting inhomogeneous objects embedded in an inhomogeneous background medium

  12. Organizational liability for adverse reactions to the contrast media

    International Nuclear Information System (INIS)

    Lim, Chang Seon

    2007-01-01

    Contrast medium is a very useful tool for X-ray examinations. But contrast medium has some unavoidable adverse reactions. For those patients who have never received contrast medium before, it is impossible to predict whether they will suffer from certain kinds of adverse reactions. Thus, radiologists should use strategies to minimize adverse events and be prepared to promptly recognize and manage any reactions to the contrast media. If a radiologist commits medical malpractice, he will face civil responsibility. Medical malpractice means a tort or breach of contrast that occurs in a medical setting. Medical malpractices happen, despite the efforts of hospital staff. Many courts have applied the traditional doctrine of respondeat superior in actions against organizations for injuries caused by their employees. It is a legal doctrine, which states that an employer is responsible for employee actions performed within the course of the employment. A hospital is an organization for health purposes. An organization may be convicted of an offense committed by an employee of the organization acting in its behalf and within the scope of this office or employment. Organizational liability involves a wide variety of legal issues, including tort liability, wrongful employment practices, personal injury, breach of fiduciary duty, and so on. Many executive directors of organizations are aware of their personal and organizational risks of exposure to legal liabilities. The employer must have the right to control the physical conduct of the employee and must consent to receive the employee's services, while expecting some benefits from the services offered. Therefore, legal liability can be imposed for improper selection, assignment, training, and supervision of employees. In conclusion, the hospital itself has organizational liability for adverse reactions to the contrast medium

  13. High-efficiency extracellular release of free fatty acids from Aspergillus oryzae using non-ionic surfactants.

    Science.gov (United States)

    Tamano, Koichi; Miura, Ai; Koike, Hideaki; Kamisaka, Yasushi; Umemura, Myco; Machida, Masayuki

    2017-04-20

    Free fatty acids (FFAs) are useful for generating biofuel compounds and functional lipids. Microbes are increasingly exploited to produce FFAs via metabolic engineering. However, in many microorganisms, FFAs accumulate in the cytosol, and disrupting cells to extract them is energy intensive. Thus, a simple cost-effective extraction technique must be developed to remove this drawback. We found that FFAs were released from cells of the filamentous fungus Aspergillus oryzae with high efficiency when they were cultured or incubated with non-ionic surfactants such as Triton X-100. The surfactants did not reduce hyphal growth, even at 5% (w/v). When the faaA disruptant was cultured with 1% Triton X-100, more than 80% of the FFAs synthesized de novo were released. When the disruptant cells grown without surfactants were incubated for 1h in 1% Triton X-100 solution, more than 50% of the FFAs synthesized de novo were also released. Other non-ionic surfactants in the same ether series, such as Brij 58, IGEPAL CA-630, and Tergitol NP-40, elicited a similar FFA release. The dry cell weight of total hyphae decreased when grown with 1% Triton X-100. The decrement was 4.9-fold greater than the weight of the released FFAs, implying release of other intracellular compounds. Analysis of the culture supernatant showed that intracellular lactate dehydrogenase was also released, suggesting that FFAs are not released by a specific transporter. Therefore, ether-type non-ionic surfactants probably cause non-specific release of FFAs and other intracellular compounds by increasing cell membrane permeability. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. SOME PHYSICOCHEMICAL PROPERTIES OF OCTYLPHENOL ETHOXYLATE NONIONICS (TRITON X-100, TRITON X-114 AND TRITON X-405 AND THE TEMPERATURE EFFECT ON THIS PROPERTIES

    Directory of Open Access Journals (Sweden)

    Taliha Sidim

    2016-11-01

    Full Text Available Surface tensions and condutvities of aqueous solutions of nonionic surfactants at various concentrations were measured at diffferent temperatures.The critical micelle concentration (CMC of aqueous solutions of three different octylphenol ethoxylate nonionics(Triton X-114, Triton X-100 and Triton X-405 are determined at different temperatures.The effect of the ethylene oxide chain length and temperature on the CMC is also determined.

  15. Experimental and clinical studies on CT lymphography

    International Nuclear Information System (INIS)

    Hirata, Yuzo; Kono, Michio

    1982-01-01

    Indirect lymphography using computed tomographic apparatus (CT Lymphography) was attempted in 15 dogs with newly devised contrast medium for the opacification of hilar and mediastinal lymphnodes. Clinical application was performed in 2 cases of lung cancer. Newly devised contrast material is an emulsion, which consists of oily contrast medium, non-ionic surfactant and glucose solution. The contrast medium was injected percutaneously into subdiaphragmatic space, or into bronchial walls by bronchofiberscopic technique. CT was able to demonstrate the opacified hilar and mediastinal nodes much more in number than demonstrated in conventional radiograms. It was true in 6 to 11 cases when injected into subdiaphragmatic spaces, and in 2 of 4 cases with an injection into bronchial walls. In clinical studies, CT revealed opacification of mediastinal nodes in one case of lung cancer. Although the procedure is still inferior to the demonstrability of routine indirect lymphography for the evaluation of the fine structure of each node, it showed no remarkable side effects. As the satisfactory method of opacifying hilar and mediastinal nodes has not yet been established, our method is thought to be of value in applying for detection of the metastatic lymphnodes. (author)

  16. High-pitch dual-source CT coronary angiography with low volumes of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Lembcke, Alexander; Hein, Patrick A.; Knobloch, Gesine; Durmus, Tahir; Hamm, Bernd [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); Schwenke, Carsten [SCO:SSiS - Schwenke Consulting, Berlin (Germany); Huppertz, Alexander [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); ISI - Imaging Science Institute Charite, Berlin (Germany)

    2014-01-15

    To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). One-hundred consecutive patients (body weight 65-85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m{sup 2}) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G{sub 30}, 30 mL; G{sub 40}, 40 mL; G{sub 50}, 50 mL; G{sub 60}, 60 mL; G{sub 70}, 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G{sub 30} to 478.2 and 571.8 HU in G{sub 70}. Mean attenuation values were higher in groups with higher CM volumes (P < 0.0001) and higher in women than in men (P < 0.0001). The proportions of segments with attenuation of at least 300 HU in G{sub 30}, G{sub 40}, G{sub 50}, G{sub 60} and G{sub 70} were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. (orig.)

  17. Improvements in gastric diagnosis by using high density contrast media with low viscosity

    International Nuclear Information System (INIS)

    Toischer, H.P.

    1983-01-01

    In a retrospective clinical study, 150 unselected double contrast examinations of the stomach using conventional contrast media (100 g/100 ml barium sulphate) were compared with a similar number of examinations using a high density contrast medium of flow viscosity (250 g/100 ml barium sulphate). The high density contrast medium was distinctly better for demonstrating detail of the gastric mucosa. The uneveness of coating and instability of the older high density contrast media was observed in 15.5% of cases and, in no instance, did this make it impossible to reach a diagnosis. (orig.) [de

  18. Experimental irradiation of the rat ureter: The effects of field size and the presence of contrast medium on incidence and latency of hydronephrosis

    International Nuclear Information System (INIS)

    Knowles, J.F.; Trott, K.R.

    1987-01-01

    Following X-irradiation of a 1.5 cm length of rat ureter, hydronephrosis developed after doses down to 10 Gy. The estimated ED 50 was 11.8 Gy. In the dose range 37.4 Gy to 17.5 Gy there was a significant increase in latency with decreasing dose, but at lower doses the latency did not increase further. Reducing the length of ureter irradiated to 0.5 cm or 0.8 cm caused a decrease in incidence of hydronephrosis and longer latency periods. The ED 50 for rats iradiated to 0.5 cm of ureter was 29.6 Gy. The possibility that secondary radiation produced as a result of interaction between X-radiation and iodinated contrast medium might affect the radiation induction of hydronephrosis was investigated. No difference was found between groups of rats irradiated with or without injection of contrast media. 39 refs.; 4 figs

  19. Comparison between radiological protection against ionizing radiation and non-ionizing radiation

    International Nuclear Information System (INIS)

    Jammet, H.P.

    1988-01-01

    The comparison of doctrines concerning protection against ionizing and non-ionizing radiation is a difficult task, because of the many areas in which it is applied. Radiological pollution has grown during the century, but its evolution has not been concomitant. This has resulted in a distortion that can be identified in the successive steps of the evaluation and protection against such radiation. For a better understanding, this discussion deals with the differences in interaction with matter and the induction of the related risks, on the varieties of protection systems and monitoring procedures

  20. Conductometric study of sodium dodecyl sulfate - nonionic surfactant (Triton X-100, Tween 20, Tween 60, Tween 80 or Tween 85 mixed micelles in aqueous solution

    Directory of Open Access Journals (Sweden)

    Ćirin Dejan M.

    2012-01-01

    Full Text Available The present study is concerned with the determination of the critical micelle concentration (cmc of mixed micelles of sodium dodecyl sulfate with one of five nonionic surfactants (Triton X-100, Tween 20, Tween 60, Tween 80 or Tween 85 from conductance measurements. Based on the calculated values of the β parameters we have noticed that SDS-nonionic surfactants mostly showed strong synergistic effect. It was found that nonionic surfactants with mainly longer and more hydrophobic tail show stronger interactions with hydrophobic part of SDS, thus expressing stronger synergism. In SDS-Tween 80 binary system the strongest synergistic effect was noticed. SDS-Tween 85 micellar system showed antagonistic effect, most probably because the presence of the double bond in its three hydrophobic tails (three C18 tails makes it sterically rigid.

  1. [Saccharomyces cerevisiae as a model organism for studying the carcinogenicity of non-ionizing electromagnetic fields and radiation].

    Science.gov (United States)

    Voĭchuk, S I

    2014-01-01

    Medical and biological aspects of the effects of non-ionizing electromagnetic (EM) fields and radiation on human health are the important issues that have arisen as a result of anthropogenic impact on the biosphere. Safe use of man-made sources of non-ionizing electromagnetic fields and radiation in a broad range of frequencies--static, radio-frequency and microwave--is a subject of discussions and speculations. The main problem is the lack of understanding of the mechanism(s) of reception of EMFs by living organisms. In this review we have analyzed the existing literature data regarding the effects of the electromagnetic radiation on the model eukaryotic organism--yeast Saccharomyces cerevisiae. An attempt was made to estimate the probability of induction of carcinogenesis in humans under the influence of magnetic fields and electromagnetic radiation of extremely low frequency, radio frequency and microwave ranges.

  2. Aspiration of Barium Contrast

    Directory of Open Access Journals (Sweden)

    Cristina Fuentes Santos

    2014-01-01

    Full Text Available The aspiration of barium contrast is a rare complication that may occur during studies of the digestive tract. Barium is an inert material that can cause anywhere from an asymptomatic mechanical obstruction to serious symptoms of respiratory distress that can result in patient death. We present the case of a 79-year-old male patient in whom we observed the presence of contrast medium residue in the lung parenchyma as an incidental finding during hospitalization. When the patient’s medical file was reviewed, images were found of a barium swallow study that the patient had undergone months earlier, and we were able to observe the exact moment of the aspiration of the contrast material. The patient had been asymptomatic since the test.

  3. Interaction of antihypertensive drug amiloride with metal ions in micellar medium using fluorescence spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Gujar, Varsha; Pundge, Vijaykumar; Ottoor, Divya, E-mail: divya@chem.unipune.ac.in

    2015-05-15

    Steady state and life time fluorescence spectroscopy have been employed to study the interaction of antihypertensive drug amiloride with biologically important metal ions i.e. Cu{sup 2+}, Fe{sup 2+}, Ni{sup 2+} and Zn{sup 2+} in various micellar media (anionic SDS (sodium dodecyl sulfate), nonionic TX-100 (triton X-100) and cationic CTAB (cetyl trimethyl ammonium bromide)). It was observed that fluorescence properties of drug remain unaltered in the absence of micellar media with increasing concentration of metal ions. However, addition of Cu{sup 2+}, Fe{sup 2+} and Ni{sup 2+} caused fluorescence quenching of amiloride in the presence of anionic micelle, SDS. Binding of drug with metal ions at the charged micellar interface could be the possible reason for this pH-dependent metal-mediated fluorescence quenching. There were no remarkable changes observed due to metal ions addition when drug was present in cationic and nonionic micellar medium. The binding constant and bimolecular quenching constant were evaluated and compared for the drug–metal complexes using Stern–Volmer equation and fluorescence lifetime values. - Highlights: • Interaction of amiloride with biologically important metal ions, Fe{sup 2+}, Cu{sup 2+}, Ni{sup 2+} and Zn{sup 2+}. • Monitoring the interaction in various micelle at different pH by fluorescence spectroscopy. • Micelles acts as receptor, amiloride as transducer and metal ions as analyte in the present system. • Interaction study provides pH dependent quenching and binding mechanism of drug with metal ions.

  4. Interaction of antihypertensive drug amiloride with metal ions in micellar medium using fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Gujar, Varsha; Pundge, Vijaykumar; Ottoor, Divya

    2015-01-01

    Steady state and life time fluorescence spectroscopy have been employed to study the interaction of antihypertensive drug amiloride with biologically important metal ions i.e. Cu 2+ , Fe 2+ , Ni 2+ and Zn 2+ in various micellar media (anionic SDS (sodium dodecyl sulfate), nonionic TX-100 (triton X-100) and cationic CTAB (cetyl trimethyl ammonium bromide)). It was observed that fluorescence properties of drug remain unaltered in the absence of micellar media with increasing concentration of metal ions. However, addition of Cu 2+ , Fe 2+ and Ni 2+ caused fluorescence quenching of amiloride in the presence of anionic micelle, SDS. Binding of drug with metal ions at the charged micellar interface could be the possible reason for this pH-dependent metal-mediated fluorescence quenching. There were no remarkable changes observed due to metal ions addition when drug was present in cationic and nonionic micellar medium. The binding constant and bimolecular quenching constant were evaluated and compared for the drug–metal complexes using Stern–Volmer equation and fluorescence lifetime values. - Highlights: • Interaction of amiloride with biologically important metal ions, Fe 2+ , Cu 2+ , Ni 2+ and Zn 2+ . • Monitoring the interaction in various micelle at different pH by fluorescence spectroscopy. • Micelles acts as receptor, amiloride as transducer and metal ions as analyte in the present system. • Interaction study provides pH dependent quenching and binding mechanism of drug with metal ions

  5. Effects of Contrast Media on Blood Rheology: Comparison in Humans, Pigs, and Sheep

    International Nuclear Information System (INIS)

    Laurent, Alexandre; Durussel, Jean Jacques; Dufaux, Jacques; Penhouet, Laurence; Bailly, Anne Laure; Bonneau, Michel; Merland, Jean Jacques

    1999-01-01

    Purpose: To compare whole blood viscosity and erythrocyte aggregation in humans, pigs, and sheep, before and after adding water-soluble iodinated contrast medium (CM). Methods: Two CMs were studied: iopromide (nonionic) and ioxaglate (ionic). The blood-CM viscosity was measured with a Couette viscometer. Erythrocyte aggregation was measured with an erythroaggregometer. Results: The blood-CM viscosity was increased up to +20% (relative to pure blood) with a CM concentration of 0%-10%. At CM concentrations from 10% to 50%, the viscosity decreased. The disaggregation shear stress was increased (relative to pure blood) at low CM concentration (0%-10%). When the CM concentration increased from 10% to 20%, the disaggregation shear stress was decreased, except with the pig blood-ioxaglate mixture. Conclusion: At low CM concentration the blood viscosity was increased in pig, sheep, and humans and the disaggregation shear stress was increased in pig and humans. The aggregation of sheep blood was too low to be detected by the erythroaggregometer. This rise can be explained by the formation of poorly deformable echinocytes. At higher CM concentration, the viscosity and the disaggregation shear stress decreased in relation to the blood dilution. We conclude that pig blood and sheep blood can both be used to study the effect of CM injection on blood viscosity. Nevertheless, the rheologic behavior of pig blood in terms of erythrocyte aggregation is closer to that of human blood than is sheep blood when mixed with CM. Pigs could thus be more suitable than sheep for in vivo studies of CM miscibility with blood during selective cannulation procedures

  6. Late adverse reactions to intravascular iodine based contrast media

    DEFF Research Database (Denmark)

    Bellin, Marie-France; Stacul, Fulvio; Webb, Judith A W

    2011-01-01

    DEFINITION: Late adverse reactions (LAR) to contrast media (CM) are defined as reactions occurring 1 h to 1 week after exposure. NEED FOR REVIEW: In view of more prospective studies of LAR and new data about their pathophysiology, the Contrast Medium Safety Committee (CMSC) of the European Society...... or delayed reading intradermal). The main risk factors for LAR are a previous reaction to contrast medium, a history of allergy, and interleukin-2 treatment. Most skin reactions are mild or moderate and self-limiting. MANAGEMENT: Management is symptomatic and similar to the management of other drug......-induced skin reactions. To reduce the risk of repeat reactions avoidance of the relevant CM and any cross-reacting agents identified by skin testing is recommended....

  7. Cell Hydration as a Biomarker for Estimation of Biological Effects of Nonionizing Radiation on Cells and Organisms

    Directory of Open Access Journals (Sweden)

    Sinerik Ayrapetyan

    2014-01-01

    Full Text Available “Changes in cell hydration” have been hypothesized as an input signal for intracellular metabolic cascade responsible for biological effects of nonionizing radiation (NIR. To test this hypothesis a comparative study on the impacts of different temperature and NIR (infrasound frequency mechanical vibration (MV, static magnetic field (SMF, extremely low frequency electromagnetic field (ELF EMF, and microwave (MW pretreated water on the hydration of barley seeds in its dormant and germination periods was performed. In dormant state temperature sensitivity (Q10 of seed hydration in distilled water (DW was less than 2, and it was nonsensitive to NIR treated DW, whereas during the germination period (48–72 hours seeds hydration exhibited temperature sensitivity Q10>2 and higher sensitivity to NIR treated DW. Obtained data allow us to suggest that the metabolic driving of intracellular water dynamics accompanied by hydrogen bonding and breaking is more sensitive to NIR-induced water structure changes in seed bathing aqua medium than the simple thermodynamic processes such as osmotic gradient driven water absorption by seeds in dormant state. Therefore, cell hydration is suggested to be a universal and extrasensitive biomarker for detection of biological effects of NIR on cells and organisms.

  8. In Vivo Evaluation of a New Embolic Spherical Particle (HepaSphere) in a Kidney Animal Model

    International Nuclear Information System (INIS)

    Luis, Esther de; Bilbao, Jose I.; Ciercoles, Jose A. Garcia Jalon de; Martinez-Cuesta, Antonio; Martino Rodriguez, Alba de; Lozano, Maria D.

    2008-01-01

    HepaSphere is a new spherical embolic material developed in a dry state that absorbs fluids and adapts to the vessel wall, leaving no space between the particle and the arterial wall. The aim of this study was to elucidate the final in vivo size, deformation, final location, and main properties of the particles when reconstituted with two different contrast media (Iodixanol and Ioxaglate) in an animal model. Two sizes of 'dry-state' particles (50-100 and 150-200 μm) were reconstituted using both ionic and nonionic contrast media. The mixture was used to partly embolize both kidneys in an animal model (14 pigs). The animals were sacrificed 4 weeks after the procedure and the samples processed. The final size of the particles was 230.2 ± 62.5 μm for the 50- to 100-μm dry-state particles and 314.4 ± 71 μm for the 150- to 200-μm dry-state particles. When the contrast medium (ionic versus nonionic) used for the reconstitution was studied to compare (Student's t-test) the final size of the particles, no differences were found (p > 0.05). The mean in vivo deformation for HepaSphere was 17.1% ± 12.3%. No differences (p > 0.05) were found in the deformation of the particle regarding the dry-state size or the contrast medium (Mann-Whitney test). We conclude that HepaSphere is stable, occludes perfectly, and morphologically adapts to the vessel lumen of the arteries embolized. There is no recanalization of the arteries 4 weeks after embolization. Its final in vivo size is predictable and the particle has the same properties in terms of size and deformation with the two different contrast media (Iodixanol and Ioxaglate)

  9. The use of iodinated and gadolinium contrast media during pregnancy and lactation

    Energy Technology Data Exchange (ETDEWEB)

    Webb, Judith A.W. [St. Bartholomew' s Hospital, Department of Diagnostic Imaging, London (United Kingdom); Thomsen, Henrik S. [Copenhagen University Hospital at Herlev, Department of Diagnostic Radiology 54E2, Herlev (Denmark); Morcos, Sameh K. [Northern General Hospital, Department of Diagnostic Imaging, Sheffield (United Kingdom)

    2005-06-01

    The use of iodinated or gadolinium-based contrast media in pregnant or lactating women often causes concerns in the radiology department because of the principle of not exposing a fetus or neonate to any drugs. Because of the uncertainty about the use of contrast media during pregnancy and lactation, the Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines. An extensive literature search was carried out and summarized in a report. Based on the limited information available, simple guidelines have been drawn up. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. Mutagenic and teratogenic effects have not been described after administration of gadolinium or iodinated contrast media. Free iodide in radiographic contrast medium given to the mother has the potential to depress fetal/neonatal thyroid function. Neonatal thyroid function should be checked during the 1st week if iodinated contrast media have been given during pregnancy. No effect on the fetus has been seen after gadolinium contrast media. Only tiny amounts of iodinated or gadolinium-based contrast medium given to a lactating mother reach the milk, and only a minute proportion entering the baby's gut is absorbed. The very small potential risk associated with absorption of contrast medium may be considered insufficient to warrant stopping breast-feeding for 24 h following either iodinated or gadolinium contrast agents. (orig.)

  10. The use of iodinated and gadolinium contrast media during pregnancy and lactation

    International Nuclear Information System (INIS)

    Webb, Judith A.W.; Thomsen, Henrik S.; Morcos, Sameh K.

    2005-01-01

    The use of iodinated or gadolinium-based contrast media in pregnant or lactating women often causes concerns in the radiology department because of the principle of not exposing a fetus or neonate to any drugs. Because of the uncertainty about the use of contrast media during pregnancy and lactation, the Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines. An extensive literature search was carried out and summarized in a report. Based on the limited information available, simple guidelines have been drawn up. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. Mutagenic and teratogenic effects have not been described after administration of gadolinium or iodinated contrast media. Free iodide in radiographic contrast medium given to the mother has the potential to depress fetal/neonatal thyroid function. Neonatal thyroid function should be checked during the 1st week if iodinated contrast media have been given during pregnancy. No effect on the fetus has been seen after gadolinium contrast media. Only tiny amounts of iodinated or gadolinium-based contrast medium given to a lactating mother reach the milk, and only a minute proportion entering the baby's gut is absorbed. The very small potential risk associated with absorption of contrast medium may be considered insufficient to warrant stopping breast-feeding for 24 h following either iodinated or gadolinium contrast agents. (orig.)

  11. Ioversol 350: clinical experience in cranial computed tomography

    International Nuclear Information System (INIS)

    Theron, J.; Paugam, J.P.; Courtheoux, P.

    1991-01-01

    A single, open trial was conducted in 40 patients to evaluate the diagnostic efficacy and safety, in cranial computed tomography, of ioversol (350 mgl/ml), a new nonionic, monomeric, low-osmolality contrast medium. Ioversol is characterized by a hydrophilicity which is not only the highest of all nonionic agents available to date, but also evenly distributed among the various sides of the benzene ring. Diagnosis was possible in 100 % of cases with a mean degree of certainty of 90.8 %. Six minor adverse reactions requiring no treatment we recorded, of which two were observed by the investigator and four reported by the patients. No pain sensation was found and heat sensations were of minor intensity. Ioversol 350, which showed good diagnostic efficacy and proved to be well tolerated, is therefore suitable for cranial computed tomography at a mean dose of 1 ml/kg

  12. Intravenous contrast media application using cone-beam computed tomography in a rabbit model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Sung; Kim, Bok Yeol; Choi, Hwa Young [Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University, Seoul (Korea, Republic of); and others

    2015-03-15

    This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.

  13. Intravenous contrast media application using cone-beam computed tomography in a rabbit model

    International Nuclear Information System (INIS)

    Kim, Min Sung; Kim, Bok Yeol; Choi, Hwa Young

    2015-01-01

    This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.

  14. Contrast-enhanced ultrasound imaging of active bleeding associated with hepatic and splenic trauma.

    Science.gov (United States)

    Lv, F; Tang, J; Luo, Y; Li, Z; Meng, X; Zhu, Z; Li, T

    2011-10-01

    The aim of this study was to evaluate contrast-enhanced ultrasound (CEUS) imaging of active bleeding from hepatic and splenic trauma. Three hundred and ninety-two patients with liver or/and spleen trauma (179 liver and 217 spleen injuries), who underwent CEUS examinations following contrast-enhanced computed tomography (CT), were enrolled in this retrospective study over a period of >4 years. CEUS detected contrast medium extravasation or pooling in 16% (63/396) of liver or spleen lesions in 61 patients, which was confirmed by contrast-enhanced CT. Special attention was paid to observing the presence, location, and characteristics of the extravasated or pooled contrast medium. The CEUS detection rate for active bleeding was not different from that of contrast-enhanced CT (p=0.333). Information from surgery, minimally invasive treatment and conservative treatment was used as reference standard, and the sensitivities of the two techniques were not different (p=0.122). Of 63 lesions in 61 patients, CEUS showed that 74.6% (47/63) (21 liver lesions and 26 spleen lesions) presented contrast medium extravasation or pooling, both in the organ and out the capsule, in 14.3% (9/63) and only outside the capsule in 11.1% (7/63). CEUS imaging of active bleeding from hepatic and splenic trauma presented various characteristics, and the sizes and shapes of the active bleeding due to contrast medium extravasation or pooling were variable. CEUS can show the active bleeding associated with hepatic and splenic trauma with various imaging characteristics, thus making it possible to diagnose active bleeding using CEUS.

  15. Motile bacteria in a critical fluid mixture

    Science.gov (United States)

    Koumakis, Nick; Devailly, Clémence; Poon, Wilson C. K.

    2018-06-01

    We studied the swimming of Escherichia coli bacteria in the vicinity of the critical point in a solution of the nonionic surfactant C12E5 in buffer solution. In phase-contrast microscopy, each swimming cell produces a transient trail behind itself lasting several seconds. Comparing quantitative image analysis with simulations show that these trails are due to local phase reorganization triggered by differential adsorption. This contrasts with similar trails seen in bacteria swimming in liquid crystals, which are due to shear effects. We show how our trails are controlled, and use them to probe the structure and dynamics of critical fluctuations in the fluid medium.

  16. In Vivo Differentiation of Complementary Contrast Media at Dual-Energy CT

    Science.gov (United States)

    Mongan, John; Rathnayake, Samira; Fu, Yanjun; Wang, Runtang; Jones, Ella F.; Gao, Dong-Wei

    2012-01-01

    Purpose: To evaluate the feasibility of using a commercially available clinical dual-energy computed tomographic (CT) scanner to differentiate the in vivo enhancement due to two simultaneously administered contrast media with complementary x-ray attenuation ratios. Materials and Methods: Approval from the institutional animal care and use committee was obtained, and National Institutes of Health guidelines for the care and use of laboratory animals were observed. Dual-energy CT was performed in a set of iodine and tungsten solution phantoms and in a rabbit in which iodinated intravenous and bismuth subsalicylate oral contrast media were administered. In addition, a second rabbit was studied after intravenous administration of iodinated and tungsten cluster contrast media. Images were processed to produce virtual monochromatic images that simulated the appearance of conventional single-energy scans, as well as material decomposition images that separate the attenuation due to each contrast medium. Results: Clear separation of each of the contrast media pairs was seen in the phantom and in both in vivo animal models. Separation of bowel lumen from vascular contrast medium allowed visualization of bowel wall enhancement that was obscured by intraluminal bowel contrast medium on conventional CT scans. Separation of two vascular contrast media in different vascular phases enabled acquisition of a perfectly coregistered CT angiogram and venous phase–enhanced CT scan simultaneously in a single examination. Conclusion: Commercially available clinical dual-energy CT scanners can help differentiate the enhancement of selected pairs of complementary contrast media in vivo. © RSNA, 2012 PMID:22778447

  17. Non-Ionizing Radiation: Nature and Protection

    International Nuclear Information System (INIS)

    Abukasem, E.; Abdemalek, H.; Mosbah, D. S.

    2011-01-01

    Last century, the humanity witnessed a vast development, after the industrial revolution, in many aspects of life. There was a real revolution in world of communications, the electromagnetic waves were produced and used in many applications like wireless communications, radio and television transmissions, information transfer, medical diagnosis and many other useful applications. Non-ionizing radiation, the radiation which has no enough energy to remove an electron from an atom, becomes indispensable life necessity and currently it is a subject of public debate about its effects and hazards on human life and environments. The Arab Atomic Energy Agency recognized this fact and tried to raise the public awareness towards by organizing seminars, workshops and expert meetings in the Arab region in order to study the theoretical and applies aspects of this type of radiation as well as to shed the light on its possible hazards and effects on human life. This booklet came as a result of many expert meetings to be an Arabic simple and comprehensive guide line about the nature of and the different methods of protection from its possible effects and hazards.(author)

  18. Determination of non-ionic surfactants in technologic liquors and effluents by X-ray fluorescent spectrometry

    International Nuclear Information System (INIS)

    Dankowski, P.; Majda, J.

    1977-01-01

    The method has been worked out for determination of non-ionic surfactants in technological liquors and effluents, based on the X-ray fluorescent spectrometry with an initial concentration by means of the phosphomolybdic acid. The method is suitable for a quantitative determination of ethylene oxide adducts in a wide range of applicable concentrations, the trace-ones included. (M.Z.)

  19. Contrast nephropathy in high-risk patients undergoing coronary angiography and intervention

    International Nuclear Information System (INIS)

    Uddin, M.A.; Rabbani, M.A.; Jafary, F.H.; Bhatti, M.A.; Islam, M.

    2005-01-01

    Objective: To determine the incidence of contrast nephropathy in high-risk patients undergoing coronary angiography and percutaneous coronary intervention (PCI), and to define the characteristics of this cohort. Design: Descriptive study. Place and Duration of Study: The Aga Khan University Hospital, Karachi from January to December 2002. Patients and Methods: One hundred and fifteen patients with serum creatinine greater than 1.4mg/dl who underwent coronary angiography or PCI were included. All patients received non-ionic contrast dye. Acute contrast nephropathy was defined as rise in serum creatinine of >0.5mg/dl within 48 hours following the index procedure. Means and standard deviations were calculated for continuous variables and frequencies for categorical variables. Results: Mean age of patients was 62.3 year + 8.83. Mean pre-contrast creatinine was 1.9+0.9mg/dl. Eleven (9.65%) patients developed contrast nephropathy. 4.4% of patients with serum creatinine 4.0(p-value 0.001). 11.9% diabetic patients developed nephropathy compared to 6.3% of non-diabetics (p-value 0.355). 11.4% of hypertensive and 3.7% of non-hypertensive patients developed contrast-nephropathy (p-value 0.454). 12.9% of low dose group ( 100ml) developed nephropathy (p-value 0.188). Mean serum creatinine in low dose group was higher (3.0mg/dl vs. 1.7 mg/dl). Conclusion: The incidence of contrast nephropathy in this study was similar to that reported in literature. Risk of CIN was found to be significantly proportional to the severity of baseline renal disease. Trends towards higher risk of CIN were seen in patients with diabetes and hypertension. Higher incidence of CIN in patients receiving low-dose contrast was confounded by higher baseline serum creatinine in that group. (author)

  20. Indication of critical micelle concentration of nonionic surfactants with large emission change using water-soluble conjugated polymer as molecular light switch

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Lilin, E-mail: sunlilin126@126.com [Anhui Key Laboratory of Chemo-Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000 (China); Hao, Dan; Zhang, Ping; Qian, Zhangsheng; Shen, Weili [Anhui Key Laboratory of Chemo-Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000 (China); Shao, Taili [Anhui Key Laboratory of Chemo-Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000 (China); Department of Pharmacy, Wannan Medical College, Wuhu 241000 (China); Zhu, Changqing, E-mail: zhucq@mail.ahnu.edu.cn [Anhui Key Laboratory of Chemo-Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000 (China)

    2013-02-15

    A new near-infrared water-soluble conjugated polymer, i.e. poly [2,5-di (propyloxysulfonate)-1,4-phenylene-ethynylene-9,10-anthrylene] (PPEASO3) was synthesized to investigate its interaction with surfactants. It was found that PPEASO3 has only a weak fluorescence emission at about 670 nm due to its self-aggregation in water and in aqueous solution containing a low concentration of nonionic surfactants, i.e. below their critical micelle concentration (CMC). However, a dramatic fluorescence enhancement with a large emission blue-shift (>40 nm) was found once the concentration of nonionic surfactants reached the CMC (especially for Triton X-100). An orange fluorescence could be observed even with naked-eyes under UV-lamp, which gave a direct indication for the micelle forming process and provided a simple method for the CMC determination of the nonionic surfactants. The CMC values determined by this method were in good agreement with those obtained by other techniques. The dramatic emission change observed could be ascribed to the intensive hydrophobic interaction between PPEASO3 and surfactants micelle, which greatly disrupts the aggregation of the polymer and increase the fluorescence efficiency of PPEASO3. Highlights: Black-Right-Pointing-Pointer Investigated the interaction of a new water-soluble conjugated polymer with surfactants. Black-Right-Pointing-Pointer The dramatic fluorescence enhancement and emission blue-shift were observed at the CMC. Black-Right-Pointing-Pointer The obvious emission color change could be observed with naked-eyes under UV-lamp. Black-Right-Pointing-Pointer Gave a direct indication for the micelle forming process. Black-Right-Pointing-Pointer Provided a simple method for the CMC determination of the nonionic surfactants.

  1. A History of the International Commission on Non-Ionizing Radiation Protection.

    Science.gov (United States)

    Repacholi, M H

    2017-10-01

    Concern about health risks from exposure to non-ionizing radiation (NIR) commenced in the 1950s after tracking radars were first introduced during the Second World War. Soon after, research on possible biological effects of microwave radiation in the former Soviet Union and the U.S. led to public and worker exposure limits being much lower in Eastern European than in Western countries, mainly because of different protection philosophies. As public concern increased, national authorities began introducing legislation to limit NIR exposures from domestic microwave ovens and workplace devices such as visual display units. The International Radiation Protection Association (IRPA) was formed in 1966 to represent national radiation protection societies. To address NIR protection issues, IRPA established a Working Group in 1974, then a Study Group in 1975, and finally the International NIR Committee (INIRC) in 1977. INIRC's publications quickly became accepted worldwide, and it was logical that it should become an independent commission. IRPA finally established the International Commission on Non-Ionizing Radiation Protection (ICNIRP), chartering its remit in 1992, and defining NIR as electromagnetic radiation (ultraviolet, visible, infrared), electromagnetic waves and fields, and infra- and ultrasound. ICNIRP's guidelines have been incorporated into legislation or adopted as standards in many countries. While ICNIRP has been subjected to criticism and close scrutiny by the public, media, and activists, it has continued to issue well-received, independent, science-based protection advice. This paper summarizes events leading to the formation of ICNIRP, its key activities up to 2017, ICNIRP's 25th anniversary year, and its future challenges.

  2. Contrast media use in patients with chronic kidney disease undergoing coronary angiography: A systematic review and meta-analysis of randomized trials.

    Science.gov (United States)

    Pandya, Bhavi; Chalhoub, Jean M; Parikh, Valay; Gaddam, Sainath; Spagnola, Jonathan; El-Sayegh, Suzanne; Bogin, Marc; Kandov, Ruben; Lafferty, James; Bangalore, Sripal

    2017-02-01

    Patients with chronic kidney disease (CKD) undergoing coronary angiography (CA), adequate hydration and minimizing volume of contrast media (CM) are class 1b recommendations for preventing contrast induced nephropathy (CIN). Current data are insufficient to justify specific recommendations about isoosmolar vs. low-osmolar contrast media by the ACCF/AHA/SCAI guidelines. Randomized trials comparing IOCM to LOCM in CKD stage 3 and above patients undergoing CA, and reporting incidence of CIN (defined by a rise in creatinine of 25% from baseline) were included in the analysis. The secondary outcome of the study was the incidence of serum creatinine increase by >1mg/dl. A total of 2839 patients were included in 10 trials, in which 1430 patients received IOCM and 1393 received LOCM. When compared to LOCM, IOCM was not associated with significant benefit in preventing CIN (OR=0.72, [CI: 0.50-1.04], P=0.08, I2=59%). Subgroup analysis revealed non-significant difference in incidence of CIN based on baseline use of N-acetylcystine (NAC), diabetes status, ejection fraction, and whether percutaneous coronary intervention vs coronary angiography alone was performed. The difference between IOCM and LOCM was further attenuated when restricted to studies with larger sample size (>250 patients) (OR=0.93; [CI: 0.66-1.30]) or when compared with non-ionic LOCM (OR=0.79, [CI: 0.52-1.21]). In patients with CKD stage 3 and above undergoing coronary angiography, use of IOCM showed overall non-significant difference in incidence of CIN compared to LOCM. The difference was further attenuated when IOCM was compared with non-ionic LOCM. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Depiction of normal gastrointestinal anatomy with MDCT: comparison of low- and high-attenuation oral contrast media.

    Science.gov (United States)

    Erturk, Sukru Mehmet; Mortelé, Koenraad J; Oliva, Maria-Raquel; Ichikawa, Tomoaki; Silverman, Stuart G; Cantisani, Vito; Pagliara, Elisa; Ros, Pablo R

    2008-04-01

    To compare low- and high-attenuation oral contrast media for depiction of normal gastrointestinal anatomy with multidetector-row computed tomography (MDCT). A prospective, randomized study of 90 consecutive patients without known or suspected gastrointestinal disease was conducted after the approval of our Institutional Review Board. All patients underwent IV contrast-enhanced abdominal and pelvic CT scans after oral administration of 900 ml of either low- or high-attenuation barium sulphate suspension. Using a five-point scale, two radiologists independently graded distention and wall visualization of stomach, duodenum, jejunum, and ileum. The degree of distention and wall visualization was compared using Mann-Whitney U-test. Duodenal, jejunal and ileal distention (pcontrast medium were significantly higher than those with high-attenuation barium sulphate preparation, for reader 1. Duodenal and jejunal wall visualization scores with low-attenuation contrast medium (pcontrast medium, for reader 2. Interobserver agreement was fair to good for both distention (kappa-range: 0.41-0.74) and wall visualization (kappa-range: 0.48-0.71). MDCT with low-attenuation contrast medium provides distention and wall visualization of the GI tract that is equal or better than high-attenuation contrast medium.

  4. In vivo magnetic resonance imaging of atherosclerotic lesions with a newly developed Evans blue-DTPA-gadolinium contrast medium in apolipoprotein-E-deficient mice.

    Science.gov (United States)

    Yasuda, Satoshi; Ikuta, Kenjiro; Uwatoku, Toyokazu; Oi, Keiji; Abe, Kohtaro; Hyodo, Fuminori; Yoshimitsu, Kengo; Sugimura, Kohtaro; Utsumi, Hideo; Katayama, Yoshiki; Shimokawa, Hiroaki

    2008-01-01

    Magnetic resonance imaging (MRI) contrast agents that specifically detect atherosclerotic plaque may be useful for the noninvasive detection of the plaque. We have recently developed a new contrast agent, Evans blue-DTPA-gadolinium (EB-DTPA-Gd), which selectively accumulates vascular lesions with endothelial removal. In this study, we examined whether EB-DTPA-Gd is also useful for in vivo imaging of atherosclerotic plaques. We used male apolipoprotein-E-deficient (ApoE-/-) mice of different ages (3, 6 and 12 months old) and age-matched male wild-type mice. After a single intravenous administration of EB-DTPA-Gd (160 microM/kg body weight), MRI T(1) signal was obtained in vivo. Increased signal intensity in the aortic wall was noted within 10-20 min after intravenous injection of EB-DTPA-Gd and was maintained for 30 min. The MRI enhancement in the aorta of ApoE-/- mice was increased in accordance with age, whereas no such enhancement was noted in wild-type mice. Histological examination demonstrated that there was a topological correlation between the site of MRI enhancement and that of atherosclerotic plaque. These results indicate that EB-DTPA-Gd is a useful MRI contrast medium for the in vivo detection of atherosclerotic plaques. Copyright (c) 2007 S. Karger AG, Basel.

  5. 2D and 3D parameter images for analysis of contrast medium enhancement based on dynamic CT and MR

    International Nuclear Information System (INIS)

    Beier, J.; Stroszczynski, C.; Oellinger, H.; Felix, R.; Buege, T.; Fleck, E.

    1998-01-01

    Aim: For dynamic contrast medium (CM) studies, parameter images exploit specific features of the time/intensity curve (TIC) of each pixel and represent these values in a new image. Existing concepts of two-dimensional CM analysis are extended for three-dimensional applications using adequate computer graphic visualization. Results: In first-pass analyses, TMIP and TG allowed the simultaneous or separted presentation of different temporal phases of the CM bolus. Correlation images emphasized regions with similarities to given TIC patterns. Three-dimensional computer graphic techniques enabled (1) anatomical/function mapping of original image and CM accumulation and (2) fused display of both spatial CM enhancement and color-encoded time of TIC peak in one common image. Conclusions: The quantifiction of presence, magnitude, and time-of-peak of CM accumulation in local image regions supports the assessment of vascularization and of ischemic or necrotic areas. (orig./AJ) [de

  6. Late adverse reactions to intravascular iodine based contrast media

    DEFF Research Database (Denmark)

    Bellin, Marie-France; Stacul, Fulvio; Webb, Judith A W

    2011-01-01

    DEFINITION: Late adverse reactions (LAR) to contrast media (CM) are defined as reactions occurring 1 h to 1 week after exposure. NEED FOR REVIEW: In view of more prospective studies of LAR and new data about their pathophysiology, the Contrast Medium Safety Committee (CMSC) of the European Societ...

  7. Depiction of normal gastrointestinal anatomy with MDCT: Comparison of low- and high-attenuation oral contrast media

    International Nuclear Information System (INIS)

    Erturk, Sukru Mehmet; Mortele, Koenraad J.; Oliva, Maria-Raquel; Ichikawa, Tomoaki; Silverman, Stuart G.; Cantisani, Vito; Pagliara, Elisa; Ros, Pablo R.

    2008-01-01

    Purpose: To compare low- and high-attenuation oral contrast media for depiction of normal gastrointestinal anatomy with multidetector-row computed tomography (MDCT). Materials and methods: A prospective, randomized study of 90 consecutive patients without known or suspected gastrointestinal disease was conducted after the approval of our Institutional Review Board. All patients underwent IV contrast-enhanced abdominal and pelvic CT scans after oral administration of 900 ml of either low- or high-attenuation barium sulphate suspension. Using a five-point scale, two radiologists independently graded distention and wall visualization of stomach, duodenum, jejunum, and ileum. The degree of distention and wall visualization was compared using Mann-Whitney U-test. Results: Duodenal, jejunal and ileal distention (p < 0.05, <0.001, <0.001, respectively) and wall visualization (p < 0.05, <0.01, <0.05, respectively) scores with low-attenuation contrast medium were significantly higher than those with high-attenuation barium sulphate preparation, for reader 1. Duodenal and jejunal wall visualization scores with low-attenuation contrast medium (p < 0.05, <0.01, respectively) were significantly higher than those with high-attenuation contrast medium, for reader 2. Interobserver agreement was fair to good for both distention (κ-range: 0.41-0.74) and wall visualization (κ-range: 0.48-0.71). Conclusion: MDCT with low-attenuation contrast medium provides distention and wall visualization of the GI tract that is equal or better than high-attenuation contrast medium

  8. End Functionalized Nonionic Water-Dispersible Conjugated Polymers.

    Science.gov (United States)

    Zhan, Ruoyu; Liu, Bin

    2017-09-01

    2,7-Dibromofluorene monomers carrying two or four oligo(ethylene glycol) (OEG) side chains are synthesized. Heck coupling between the monomers and 1,4-divinylbenzene followed by end capping with [4-(4-bromophenoxy)butyl]carbamic acid tert-butyl ester leads to two nonionic water-dispersible poly(fluorene-alt-1,4-divinylenephenylene)s end-functionalized with amine groups after hydrolysis. In water, the polymer with a lower OEG density (P1) has poor water dispersibility with a quantum yield of 0.24, while the polymer with a higher OEG density (P2) possesses excellent water-dispersibility with a high quantum yield of 0.45. Both polymers show fluorescence enhancement and blue-shifted absorption and emission maxima in the presence of surfactant sodium dodecyl sulfate and dodecyltrimethylammonium bromide. The polymers are also resistant to ionic strength with minimal nonspecific interactions to bovine serum albumin. When biotin is incorporated into the end of the polymer backbones through N-hydroxysuccinimide/amine coupling reaction, the biotinylated polymers interact specifically with streptavidin on solid surface. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Cervical myelography in dogs using iohexol

    International Nuclear Information System (INIS)

    Wood, A.K.; Farrow, B.R.H.; Fairburn, A.J.; Sydney Univ.; Sydney Univ.

    1985-01-01

    Iohexol, a non-ionic water-soluble radiographic contrast medium, was used for cervical myelography in dogs (10-17 kg). The animals remained clinically normal following myelography, with no evidence of seizures. At 10 days after myelography there was a slight, but significant (p<0.05) increase in neutrophils in the cerebrospinal fluid; these cell numbers had returned to normal by the time of necropsy at 60 days after myelography. This investigation suggests that iohexol may be suitable for clinical myelography in the dog. (orig.)

  10. One-step synthesis, wettability and foaming properties of high-performance non-ionic hydro-fluorocarbon hybrid surfactants

    Science.gov (United States)

    Peng, Ying-ying; Lu, Feng; Tong, Qing-Xiao

    2018-03-01

    In this work, a series of non-ionic hydro-fluorocarbon hybrid surfactants (C9F19CONH(CH2)3N(CmH2m+1)2, abbreviated as C9F19AM (m = 1), C9F19AE (m = 2) and C9F19AB (m = 4) were easily synthesized by one-step reaction and characterized by 1HNMR, 19FNMR and MS spectroscopy. Unlike conventional non-ionic surfactants (most hydrophilic units consisted of hydroxy or ether groups), their hydrophilic groups were composed of amide group, an eco-friendly unit. The surface activity, wettability, thermal stability and foaming performance were investigated. The results showed that the C9F19AE (C9F19CONH(CH2)3N[CH2CH3]2) had superior surface and interface activities, which could reduce the surface tension of water down to 15.37 mN/m and the interfacial tension (cyclohexane/water/surfactants) to 5.8 mN/m with a low cmc (critical micelle concentration) of 0.12 mmol/L. Through the calculation of Amin (the minimum area occupied per-surfactant molecule), we speculated this higher surface activity was related to the compatibility between hydrocarbon and fluorocarbon chains. When used as wetting and foaming agents, the C9F19AE also outperformed great advantages over conventional non-ionic fluorocarbon and hydrocarbon surfactants, which could decrease the contact angle of water on PTFE plate from 107.7° to 3.6°, and increase the foam integrated value F to 536 500 ± 3066.5 mL s. Moreover, the decomposition temperature (Td) of C9F19AE could reach up to 173 °C. This work demonstrates a valuable strategy to develop a kind of high-efficiency foaming agent via facile synthesis.

  11. Alterations of serum potassium, serum magnesium and adenosine diphosphate due to various contrast media containing iodine

    International Nuclear Information System (INIS)

    Lehrberger, G.

    1979-01-01

    As an introduction of the chemical structure of contrast media is explained. Then follows a survey about the complication rates in examinations with intravascularly applicable iodine-containing contrast media. In the next part clinical symptoms and signs of general and localized contrast media incompatibility reactions, the contrast medium protein reaction and the relationship between allergic reaction and contrast medium are explained. It was tried to attribute the large amount of side-effects to one primary reaction. In this connection the three above-mentioned components were investigated. (orig./MG) [de

  12. Modeling the effect of structural details of nonionic surfactant on micellization in solution and adsorption onto hydrophobic surfaces

    NARCIS (Netherlands)

    Jodar-Reyes, A.B.; Ortega-Vinuesa, J.L.; Martin-Rodriguez, A.; Leermakers, F.A.M.

    2002-01-01

    Applying the classical one-gradient self-consistent-field (SCF) theory for adsorption and/or association, we can show that the molecular architecture of nonionic surfactants influences strongly the micellization in solution and the adsorption on solid-liquid interfaces. This is illustrated by using

  13. Contrast Agent in Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Vu-Quang, Hieu

    2015-01-01

    Nanoparticles have been employed as contrast agent in magnetic resonance imaging (MRI) in order to improve sensitivity and accuracy in diagnosis. In addition, these contrast agents are potentially combined with other therapeutic compounds or near infrared bio-imaging (NIR) fluorophores to obtain...... theranostic or dual imaging purposes, respectively. There were two main types of MRI contrast agent that were synthesized during this PhD project including fluorine containing nanoparticles and magnetic nanoparticles. In regard of fluorine containing nanoparticles, there were two types contrast agent...... cancer cells for cancer diagnosis in MRI. F127-Folate coated SPION were stable in various types of suspension medium for over six months. They could specifically target folate receptor of cancer cells in vitro and in vivo thus enhancing the contrast in MRI T2/T2* weighted images. These are preliminary...

  14. Mutagenic action of non-ionizing radiations: its implication in radiation protection

    International Nuclear Information System (INIS)

    Madhvanath, U.; Subrahmanyam, P.; Sankaranarayanan, N.; Singh, D.R.

    1977-01-01

    Mutagenic effects of non-ionizing radiations except in the ultraviolet and near ultraviolet region are just not known. Results of the investigation carried out using a sensitive diploid yeast system, are presented. The arginine requiring mutant yeast strain BZ34 reverts to prototrophy following exposure to ionizing radiation. Reversion frequencies were determined following exposure to UV (254 nm), near ultraviolet (313, 353 nm) visible region (480 nm), neodymium laser (1.01 μm) and microwave (2450 MHz) radiations. An Aminco - Bowman Spectrophotofluorimeter was used to obtain wavelengths from UV to visible region. Yeast suspensions (concentration of 10 7 cells/ml) were irradiated to doses ranging from 10 7 to 10 9 erg/cm 3 as determined with potassium ferri-oxalate system. Exposure to laser pulses and microwave radiation ranged up to 45 J/cm 2 and 60 mW-h/cm 2 respectively. Results showed that the reversion induction efficiency decreased by six orders of magnitude from ionizing radiations to ultraviolet for the same absorbed dose and this efficiency has further decreased by a factor of fifteen when the wavelength is increased from 254 nm to 313 nm. Although killing could be effected with laser beams (45 J/cm 2 for 50% survival) no increase in the reversion was observed than the background level. It is concluded that radiation of wavelengths higher than 450 nm up to 12 cm studied is not mutagenic and with sufficient intensities of these radiations only killing of cells is possible due to thermal effects. This finding is compared with other known functional and morphological effects at cellular level due to low-level exposures of non-ionizing radiations

  15. Local drug delivery - the early Berlin experience: single drug administration versus sustained release.

    Science.gov (United States)

    Speck, Ulrich; Scheller, Bruno; Rutsch, Wolfgang; Laule, Michael; Stangl, Verena

    2011-05-01

    Our initial investigations into restenosis inhibition by local drug delivery were prompted by reports on an improved outcome of coronary interventions, including a lower rate of target lesion revascularisation, when the intervention was performed with an ionic instead of non-ionic contrast medium. Although this was not confirmed in an animal study, the short exposure of the vessel wall to paclitaxel dissolved in contrast agent or coated on balloons proved to be efficacious. A study comparing three methods of local drug delivery to the coronary artery in pigs indicated the following order of efficacy in inhibiting neointimal proliferation: paclitaxel-coated balloons > sirolimus-eluting stents, sustained drug release > paclitaxel in contrast medium. Cell culture experiments confirmed that cell proliferation can be inhibited by very short exposure to the drug. Shorter exposure times require higher drug concentrations. Effective paclitaxel concentrations in porcine arteries are achieved when the drug is dissolved in contrast medium or coated on balloons. Paclitaxel is an exceptional drug in that it stays in the treated tissue for a long time. This may explain the long-lasting efficacy of paclitaxel-coated balloons, but does not disprove the hypothesis that the agent blocks a process initiating long-lasting excessive neointimal proliferation, which occurs early after vessel injury.

  16. Diagnosis of deep vein thrombosis using multi-detector helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Masashi; Minamiguchi, Hiroki; Sahara, Shinya [Wakayama Medical Coll. (Japan)] [and others

    2002-11-01

    The purpose of this study was to evaluate the usefulness of multi-detector helical CT (MDHCT) with contrast medium in the diagnosis of deep vein thrombosis (DVT). The bilateral veins of the dorsal pedis in 45 patients (12 men, 33 women; average age, 64 years) under clinical suspicion of DVT were first punctured using 22-G needles. Then CT scanning from the level of the foot to the inferior vena cava was started 20 sec after the initial injection of 200 mL of dilute contrast medium (50 mL nonionic iodinated contrast medium of 300 mgI/mL and 150 mL saline) at a rate of 5 mL/sec. Two patients were excluded because of unsuccessful venous puncture. The average scanning time in 43 patients was 38.5{+-}7.9 seconds. Images of veins from the foot to the inferior vena cava were clearly demonstrated in each case. MDHCT showed DVT in 32 cases and patent deep vein in 11 cases. Simultaneous venography of the lower extremity in 18 patients clearly visualized DVT at the same level detected by contrast MDHCT. MDHCT for the diagnosis of DVT has the advantages of wider scanning rage, shorter scanning time, and finer Z-axis resolution than the other diagnostic modalities. (author)

  17. Diagnosis of deep vein thrombosis using multi-detector helical CT

    International Nuclear Information System (INIS)

    Kimura, Masashi; Minamiguchi, Hiroki; Sahara, Shinya

    2002-01-01

    The purpose of this study was to evaluate the usefulness of multi-detector helical CT (MDHCT) with contrast medium in the diagnosis of deep vein thrombosis (DVT). The bilateral veins of the dorsal pedis in 45 patients (12 men, 33 women; average age, 64 years) under clinical suspicion of DVT were first punctured using 22-G needles. Then CT scanning from the level of the foot to the inferior vena cava was started 20 sec after the initial injection of 200 mL of dilute contrast medium (50 mL nonionic iodinated contrast medium of 300 mgI/mL and 150 mL saline) at a rate of 5 mL/sec. Two patients were excluded because of unsuccessful venous puncture. The average scanning time in 43 patients was 38.5±7.9 seconds. Images of veins from the foot to the inferior vena cava were clearly demonstrated in each case. MDHCT showed DVT in 32 cases and patent deep vein in 11 cases. Simultaneous venography of the lower extremity in 18 patients clearly visualized DVT at the same level detected by contrast MDHCT. MDHCT for the diagnosis of DVT has the advantages of wider scanning rage, shorter scanning time, and finer Z-axis resolution than the other diagnostic modalities. (author)

  18. Evaluation of an ODS column modified with zwitterionic/nonionic mixed surfactants and its application to direct injection determination of inorganic anions.

    Science.gov (United States)

    Hasegawa, Takuya; Umemura, Tomonari; Koide, Akira; Chiba, Koichi; Ueki, Yuji; Tsunoda, Kin-ichi; Haraguchi, Hiroki

    2005-08-01

    An octadecylsilica (ODS) column modified with zwitterionic/nonionic mixed surfactants was evaluated for the direct injection determination of inorganic anions in biological fluids by ion chromatography. A zwitterionic surfactant (sulfobetaine-type) and a nonionic surfactant (polyoxyethylene-type) were used for a stationary-phase modification. When aqueous electrolyte solutions with concentrations of sub-mM to several mM were used as a mobile phase, the zwitterionic surfactant coated on the ODS surface exhibited unique separation selectivity for ionic species, while the nonionic surfactant coated on the ODS might have formed a hydrophilic network over the ODS surface and restricted matrix proteins from adsorbing on the stationary phase. Consequently, the mixed surfactant-modified column system allowed an efficient ion chromatographic separation of inorganic anions as well as a size-exclusive removal of column-fouling proteins. This separation system was applied to the direct injection determination of UV-absorbing anions in human saliva. The detection limits for nitrite, nitrate, iodide and thiocyanate were 3.1, 2.7, 4.5 and 25 microM, respectively, with UV detection at 210 nm (injection volume; 20 microl), and their relative standard deviations for 5 replicate measurements of saliva samples spiked with 100 microM each of those anions were 1.4, 0.9, 2.2 and 5.5%, respectively.

  19. Contrast medium at the site of the anastomosis is crucial in detecting anastomotic leakage with CT imaging after colorectal surgery.

    Science.gov (United States)

    Huiberts, Astrid A M; Dijksman, Lea M; Boer, Simone A; Krul, Eveline J T; Peringa, Jan; Donkervoort, Sandra C

    2015-06-01

    The use of computed tomography (CT) to detect anastomotic leakage (AL) is becoming the standard of care. Accurate detection of AL is crucial. The aim of this study was to define CT criteria that are most predictive for AL. From January 2006 to December 2012, all consecutive patients who had undergone CT imaging because of clinical suspicion of anastomotic leakage after colorectal surgery were analysed. All CT scans were re-evaluated by two independent abdominal radiologists blinded for clinical outcome. The images were scored with a set of criteria and a conclusion whether or not AL was present was drawn. Each separate criterion was analysed for its value in predicting AL by uni- and multivariable logistic regression Of 668 patients with colorectal surgery, 108 had undergone CT imaging within 16 days postoperatively. According to our standard of reference, 34 (31%) of the patients had AL. Univariable analysis showed that "fluid near anastomosis" (radiologist 1 (rad 1), p leakage" (rad 1, p leakage was the only independent predictor for AL in multivariable analysis for both radiologists (rad 1, OR 5.43 (95% CI 1.18-25.02); rad 2, OR 8.51 (95% CI 2.21-32.83)). The only independent variable predicting AL is leakage of contrast medium. To improve the accuracy of CT imaging, optimal contrast administration near the anastomosis appears to be crucial.

  20. Contrast induced nephropathy in hypertensive patients after elective percutaneous coronary intervention

    Science.gov (United States)

    Aryfa Andra, Cut; Khairul, Andi; Aria Arina, Cut; Mukhtar, Zulfikri; Nyak Kaoy, Isfanuddin

    2018-03-01

    Contrast induced nephropathy (CIN) is the third lead cause of hospital acquired renal failure and was associated with significant morbidity and mortality. We hypothesized that hypertension is an independent risk factor for the development of CIN in patients undergoing elective percutaneous coronary intervention (PCI). The case-control method was used, 138 patients scheduled for elective PCI. We measured serum creatinine at baseline and after 24 hours of the procedure. CIN was defined as arising in serum creatinine of at least 44 μmol/l (0,5 mg/dl) or 25% rise from baseline. All patients received low osmolality nonionic contrast during PCI. Hypertension was defined as self-reported a history of treated or untreated diagnosed high blood pressure. One hundred thirty-eight patients (74,6%) were male, and 35 patients (25,4%) were female. Among the 138 patients, 86 (62,3%) were hypertensive patients whereas 52 (37,7%) were nonhypertensive patients. There was no difference in baseline serum creatinine levels and the amount of contrast media in patient with and without CIN. CIN developed in 42 patients, 39 patients (92,9%) were hypertensive compared to 3 patients (7,1%) without hypertension with p value < 0,05. (Odds ratio 16,8, 95% CI 4.542 - 62,412). This study showed that hypertension was a risk factor for the development of CIN

  1. Contrast enhancement of the gyri in herpes simplex encephalitis

    International Nuclear Information System (INIS)

    Schumacher, K.A.; Langer, M.; Langer, R.

    1982-01-01

    A case of herpes simplex encephalitis was examined by computer tomography. Both cerebral hemispheres showed contrast enhancement of the gyri. The cause of this is considered. The increased contrast medium accumulation in the affected areas is probably due to the marked vascular proliferation which can be demonstrated anatomically, and to the rapid escape of contrast from the capillaries into the interstitial spaces. The findings of other authors, which differ somewhat, are discussed. (orig.) [de

  2. PEGylated non-ionic surfactant vesicles as drug delivery systems for Gambogenic acid.

    Science.gov (United States)

    Lin, Tongyuan; Fang, Qingying; Peng, Daiyin; Huang, Xia; Zhu, Tingting; Luo, Qing; Zhou, Kai; Chen, Weidong

    2013-01-01

    Gambogenic acid (GNA), a popular Chinese traditional medicine, has its limitations of coming into use due to its low aqueous solubility and poor bioavailability. In this study, therefore, the PEGylated non-ionic surfactant vesicles drug delivery systems were prepared from biocompatible non-ionic surfactant of Span60, cholesterol and dicetyl phosphate (DCP) by the improved ethanol injection method, and were modified with a polyethylene glycol monostearate15 (PEG15-SA). PEG15-SA, as a biocompatible, non-toxic and non-immunogenic hydrophilic segment, was grafted onto the surface of colloidal niosomes carries to reduce the uptake by the reticuloendothelial system (RES), prolonging the circulation time and attaining higher entrapment efficiency. To our knowledge, this work is the first to report that PEG15-SA was applied to coating of niosomes for encapsulation of GNA. The optimized PEG-GNA-NISVs (P-GNA-NISVs) were characterized in terms of mean vesicles size, polydispersity index (PDI), Zeta potential and entrapment efficiency of the P-GNA-NISVs. The results showed that the mean diameter, PDI, Zeta potential, and the entrapment efficiency of the P-GNA-NISVs were 70.1 nm, 0.166, -44.3 mV and 87.74%, respectively. Furthermore, the release studies of GNA from PEGylated niosomes in vitro and the pharmacokinetics in vivo exhibited a prolonged release profile as studied over 24 h. In conclusion, the result suggests that P-GNA-NISVs prepared in this way not only have higher encapsulation capacity, more colloidal stability but also offer an approach that the PEGylated niosomes is a promising carrier for anticancer GNA.

  3. Comparison of Allergic Adverse Effects and Contrast Enhancement Between Iodixanol and Iopromide

    International Nuclear Information System (INIS)

    Gharekhanloo, Farideh; Torabian, Saadat

    2012-01-01

    Iodinated X-ray contrast media are the most commonly used contrast agents in the world with an annual application of 40-50 million. New non-ionic contrast agents are subdivided into low osmolar agents such as iopromide and iso-osmolar agents such as iodixanol. Regarding different biochemical characteristics, these agents are different in the allergic reactions and contrast enhancement and final lesion conspicuity. This study was carried out to compare allergic adverse effects and contrast enhancement between iodixanol and iopromide. One-hundred and twenty patients who were referred for abdominal CT scan to Besat Hospital were included in this study. Patients were randomly divided into two groups (A and B). Group A received 100 cc iodixanol (300 mgI/mL) and group B received 100 cc iopromide (300 mgI/ml) by power injector. CT examination was performed using Helical CT Scanner (Somatom, Siemens, Germany). Sixty seconds after injection, images were obtained and enhancement of port, liver and aorta were determined. Allergic adverse effects were recorded one hour and up to one week after injection. Iodixanol produced a significantly greater enhancement of the hepatic, aorta and portal vein than iopromide (P < 0.01). Sixty seconds after injection, associated pain and heat sensation were less frequent in iodixanol in comparison with iopromide (P = 0.03). Immediate reactions such as nausea and vomiting were less frequent in iodixanol (P = 0.01). Late skin reactions such as rash was more frequent in iodixanol (P < 0.01). Iodixanol is safe and is better tolerated in the early phase of injection with better contrast enhancement and lesion conspicuity. Mild late skin rash is its disadvantage

  4. Investigation of X-ray permeability of surgical gloves coated with different contrast agents

    Science.gov (United States)

    Kayan, Mustafa; Yaşar, Selçuk; Saygın, Mustafa; Yılmaz, Ömer; Aktaş, Aykut Recep; Kayan, Fatmanur; Türker, Yasin; Çetinkaya, Gürsel

    2016-01-01

    Objective: We aimed to investigate the effectiveness and radiation protection capability of latex gloves coated with various contrast agents as an alternative to lead gloves. Methods: The following six groups were created to evaluate the permeability of X-ray in this experimental study: lead gloves, two different non-ionic contrast media (iopromide 370/100 mg I/mL and iomeprol 400/100 mg I/mL), 10% povidone–iodine (PV–I), 240/240 g/mL barium sulphate and a mixture of equal amounts of all contrast agents. A radiation dose detector was placed in coated latex gloves for each one. The absorption values of radiation from latex gloves coated with various contrast agents were measured and compared with the absorption of radiation from lead gloves. This study was designed as an ‘experimental study’. Results: The mean absorption value of X-ray from lead gloves was 3.0±0.08 µG/s. The mean absorption values of X-ray from latex gloves coated with various contrast agents were 3.7±0.09 µG/s (iopromide 370/100 mg I/mL), 3.6±0.09 µG/s (iomeprol 400/100 mg I/mL), 3.7±0.04 µG/s (PV–I), 3.1±0.07 µG/s (barium sulphate) and 3.8±0.05 µG/s (mixture of all contrast agents). Latex gloves coated with barium sulphate provided the best radiation absorption compared with latex gloves coated with other radiodense contrast agents. Conclusion: Latex gloves coated with barium sulphate may provide protection equivalent to lead gloves. PMID:26680548

  5. Endovascular revascularization of TASC C and D femoropopliteal occlusive disease using carbon dioxide as contrast

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, Cynthia de Almeida; Teivelis, Marcelo Passos; Kuzniec, Sergio; Fukuda, Juliana Maria; Wolosker, Nelson [Hospital Israelita Albert Einstein, São Paulo, SP (Brazil)

    2016-07-01

    To analyze the results of ten angioplasties of TASC C and D femoropopliteal lesions using CO{sub 2} as primary contrast in patients with no formal contraindication to iodine, aiming to decrease allergic reactions and potential nephrotoxicity in high-risk patients. We describe the results of ten angioplasties of TASC C and D femoropopliteal lesions using CO{sub 2} as primary contrast in patients with high risk for open revascularization and no formal contraindication to iodine. We analyzed feasibility of the procedures, complications, quality of the angiographic images, clinical and surgical outcomes, and costs of C and D lesions treated using CO{sub 2} as contrast medium. The use of CO{sub 2} in C and D lesions needed iodine complementation in most of the cases (nine cases) but decreased the potential nephrotoxicity of iodine contrast medium by the reduction of its volume in this group of high-risk patients. The extension of the arterial lesions was the factor that most contributed to the need for iodine supplementation due to the difficulty to visualize the refill after a long arterial occlusion. The use of CO{sub 2} as contrast in patients with C and D lesions with no restriction for iodine contrast medium was an alternative that did not dismiss the need of iodine supplementation in most of the cases, but could decrease the potential nephrotoxicity of iodine constrast medium.

  6. Automatic Time Sequence Alignment in Contrast Enhanced MRI by Maximization of Mutual Information

    National Research Council Canada - National Science Library

    Positano, Vicenzo

    2001-01-01

    The use of contrast medium allows joining the high-resolution anatomical information provided by standard magnetic resonance with functional information obtained by means of the diffusion of contrast...

  7. Equilibrium-phase MR angiography: Comparison of unspecific extracellular and protein-binding gadolinium-based contrast media with respect to image quality.

    Science.gov (United States)

    Erb-Eigner, Katharina; Taupitz, Matthias; Asbach, Patrick

    2016-01-01

    The purpose of this study was to compare contrast and image quality of whole-body equilibrium-phase high-spatial-resolution MR angiography using a non-protein-binding unspecific extracellular gadolinium-based contrast medium with that of two contrast media with different protein-binding properties. 45 patients were examined using either 15 mL of gadobutrol (non-protein-binding, n = 15), 32 mL of gadobenate dimeglumine (weakly protein binding, n = 15) or 11 mL gadofosveset trisodium (protein binding, n = 15) followed by equilibrium-phase high-spatial-resolution MR-angiography of four consecutive anatomic regions. The time elapsed between the contrast injection and the beginning of the equilibrium-phase image acquisition in the respective region was measured and was up to 21 min. Signal intensity was measured in two vessels per region and in muscle tissue. Relative contrast (RC) values were calculated. Vessel contrast, artifacts and image quality were rated by two radiologists in consensus on a five-point scale. Compared with gadobutrol, gadofosveset trisodium revealed significantly higher RC values only when acquired later than 15 min after bolus injection. Otherwise, no significant differences between the three contrast media were found regarding vascular contrast and image quality. Equilibrium-phase high-spatial-resolution MR-angiography using a weakly protein-binding or even non-protein-binding contrast medium is equivalent to using a stronger protein-binding contrast medium when image acquisition is within the first 15 min after contrast injection, and allows depiction of the vasculature with high contrast and image quality. The protein-binding contrast medium was superior for imaging only later than 15 min after contrast medium injection. Copyright © 2015 John Wiley & Sons, Ltd.

  8. High-pitch coronary CT angiography at 70 kVp adopting a protocol of low injection speed and low volume of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Ruiqi; Liu, Xiao Fei; Zhao, Yu; Zhang, Liang [Dept. of Radiology, The First Affiliated Hospital of China Medical University, Shenyang (China); Tong, Jia Jie [Dept. of Radiology, Hebei General Hospital, Shijiazhuang(China)

    2017-09-15

    To evaluate the feasibility and image quality (IQ) of prospectively high-pitch coronary CT angiography (CCTA) with low contrast medium injection rate at 70 kVp. One hundred and four patients with suspected coronary artery disease (body mass index < 26 kg/m{sup 2}, sinus rhythm and heart rate < 70 beats/min) were prospectively enrolled and randomly divided into two groups. In group A and group B, 28 mL and 40 mL of 370 mgI/mL iodinated contrast media was administrated at a flow rate of 3.5 and 5 mL/s, respectively. CT values, noise, signal-to-noise ratio, contrast-to-noise ratio (CNR) of the proximal segments of coronary arteries and subjective IQ were evaluated. The CT values and noise in group A were significantly lower than those in group B (434–485 Hounsfield units [HU] vs. 772–851 HU, all p < 0.001; 17.8–22.3 vs. 23.3–26.4, all p < 0.005). The CNRs of the right coronary artery and left main artery showed no statistical difference between the two groups (42.1 ± 13.8 vs. 36.8 ± 16.0, p = 0.074; 38.7 ± 10.6 vs. 38.1 ± 17.0, p = 0.819). No statistical difference was observed between the two groups in IQ scores (3.04 ± 0.75 vs. 3.0 ± 0.79, p = 0.526) and diagnostic ratio (96.1% [50/52] vs. 94.2% [49/52], p = 0.647). Prospective high-pitch CCTA at 70 kVp with 28 mL of contrast media and injection rate of 3.5 mL/s could provide diagnostic IQ for normal-weight patients with heart rate of < 70 beats/min.

  9. The use of Metrizamid in experimental renal angiography

    International Nuclear Information System (INIS)

    Pokorny, L.; Kelemen, J.

    1980-01-01

    A possible application of the non-ionizing contrast material metrizamid (Amipaque Vascularsup(R), Amipaquesup(R)) for renal angiography was experimentally investigated in dogs. 1.5, 3, 10 or 25 ml contrast medium was injected into one kidney. The animals were killed immediately, 3 hours, 24 hours, 7 or 28 days after angiography, and the kidneys were histologically investigated. In several cases the angiograms showed small alterations (transitory vasospasm, inhomogeneous spots on the nephrogram). Histology revealed in the initial period a homogeneous, pinkish, protein-like substance in the Bowman capsule and in the lumen of the tubuli, whereas later infiltrations by round cells and local accumulation of connective tissues were found. (L.E.)

  10. Intravenous injection of ioxilan, iohexol and diatrizoate

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Dorph, S.; Mygind, T.; Sovak, M.; Nielsen, H.; Rygaard, H.; Larsen, S.; Skaarup, P.; Hemmingsen, L.; Holm, J.

    1988-01-01

    Effects of intravenous ioxilan, a new third generation non-ionic contrast medium, diatrizoate, iohexol and saline on urine profiles were compared. Albumin, glucose, sodium, phosphate, and the enzymes NAG, LDH and GGT were followed in 24 normal rats over 7 days. Diatrizoate significantly affected all profile components during the first two hours. Albuminuria was significantly greater after diatrizoate than after iohexol or ioxilan, and excretion of glucose, LDH and GGT was significantly higher than after ioxilan. Both iohexol and ioxilan increased the excretion of albumin, LDH and GGT, while iohexol also significantly increased excretion of glucose and sodium. There was a greater excretion of glucose and GGT after iohexol than after ioxilan. Saline did not induce any changes. At day 7, serum sodium, urea, creatinine, and albumin were normal for all test substances, and kidney histology revealed no difference between the groups of animals. It is thus concluded that both high osmolar ionic and low osmolar non-ionic contrast media may cause temporary glomerular and tubular dysfunction in rats. In this model, the kidney is affected most by diatrizoate, less by iohexol, and least by ioxilan. (orig.)

  11. Gadolinium-DTPA as an oral contrast medium for MR tomography of the abdomen

    International Nuclear Information System (INIS)

    Krahe, T.; Doelken, W.; Lackner, K.; Houselog, M.

    1990-01-01

    150 MR examinations of the upper abdomen were carried out after the oral administration of 5 ml/kg body weight of a gadolinium DTPA formulation (1.0 mmol/l, 15 g/l manitol), with reference to the delineation of the pancreas, the liver and intra-abdominal fat. For comparison, 100 MR examinations without oral opacification of the G.I. tract were evaluated. Contrast administration resulted in a signal-intensive demonstration of the G.I tract for all measurement sequences. The intraluminal contrast improved the distinction between normal and abnormal structures, T 1 and T 2 sequences and the demonstration of fat on T 2 -weighted series. T 1 -weighted series showed the best diagnostic results. In 25% there was meteorism and diarrhoea within 24 hours of the administration of the oral contrast. (orig.) [de

  12. Bioadhesive agents in addition to oral contrast media - evaluation in an animal model

    International Nuclear Information System (INIS)

    Conrad, R.; Schneider, G.; Textor, J.; Schild, H.H.; Fimmers, R.

    1998-01-01

    Purpose: To evaluate the additional effect of bioadhesives in combination with iotrolan and barium as oral contrast media in an animal model. Method: The bioadhesives Noveon, CMC, Tylose and Carbopol 934 were added to iotrolan and barium. The solutions were administered to rabbits by a feeding tube. The animals were investigated by computed tomography (CT) and radiography after 0,5, 4, 12, 24 and in part after 48 hours. Mucosal coating and contrast filling of the bowel were evaluated. Results: Addition of bioadhesives to oral contrast media effected long-term contrast in the small intestine and colon, but no improvement in continuous filling and coating of the gastrointestinal tract was detected. Mucosal coating was seen only in short regions of the caecum and small intestine. In CT the best results for coating were observed with tylose and CMC, in radiography additionally with carbopol and noveon. All contrast medium solutions were well tolerated. Conclusion: The evaluated contrast medium solutions with bioadhesives have shown long-term contrast but no improvement in coating in comparison to conventional oral contrast media. (orig.) [de

  13. An historical overview of the activities in the field of exposure and risk assessment of non-ionizing radiation in Bulgaria.

    Science.gov (United States)

    Israel, Michel

    2015-09-01

    The exposure and risk evaluation process in Bulgaria concerning non-ionizing radiation health and safety started in the early 1970s. Then, the first research laboratory "Electromagnetic fields in the working environment" was founded in the framework of the Centre of Hygiene, belonging to the Medical Academy, Sofia. The main activities were connected with developing legislation, new equipment for measurement of electromagnetic fields, new methods for measurement and exposure assessment, in vivo and human studies for developing methods, studying the effect of non-ionizing radiation on human body, developing exposure limits. Most of the occupations as metal industry, plastic welding, energetics, physiotherapy, broadcasting, telephone stations, computer industry, etc., have been covered by epidemiological investigations and risk evaluation. In 1986, the ANSI standard for safe use of lasers has been implemented as national legislation that gave the start for studies in the field of risk assessment concerning the use of lasers in industry and medicine. The environmental exposure studies started in 1991 following the very fast implementation of the telecommunication technologies. Now, funds for research are very insignificant, and studies in the field of risk assessment are very few. Nevertheless, Bulgaria has been an active member of the WHO International EMF Project, since 1997, and that gives good opportunity for collaboration with other Member states, and for implementation of new approach in the EMF policy for workers and people's protection against non-ionizing radiation exposure.

  14. The experimental study of the effect of dexamethasone, lidocaine and contrast medium on the activity of collagenase

    International Nuclear Information System (INIS)

    Wu Zhiqun; Liu Weimin; Li Zhonghua; Yang Peng

    2007-01-01

    Objective: To study the effects of hormone, anesthetic and contrast medium on the activities of collagenase lysis. Methods: Nuclear tissues were divided into equal amount for different groups and same units of collagenase were used for the lysis. The only difference in the control group from experimental groups was that there were no dexamethasone, lidocaine or omnipaque but existing in experimental groups. Twenty four hours later, the concentrations of the hydroxyproline were determined in different groups and the data were analyzed by statistical software with computer. Results: 1. The concentrations of hydroxyproline in the dexamethasone group, lidocaine group and omnipaque group were significantly lower than that of control group, especially that of lidocaine group, P value was <0.05 or 0.01. 2. The concentrations of hydroxyproline in the dexamethasone + lidocaine group, dexamethasone + omnipaque group, lidocaine+omnipaque group and dexamethasone + lidocaine + omnipaque group were significantly lower than that of control group; and simultaneously lower in dexamethasone group, lidocaine group, omnipaque group respectively; P value was also <0.05 or 0.01. Conclusion: Dexamethasone, lidocaine and omnipaque can individually inhibit the activity of collagenase at different degrees, so they shouldn't be used together with collagenase in treating the lumber disc herniation. (authors)

  15. Use of Iodine-based contrast media in digital full-field mammography - initial experience

    International Nuclear Information System (INIS)

    Diekmann, F.; Diekmann, S.; Taupitz, M.; Bick, U.; Winzer, K.-J.; Huettner, C.; Muller, S.; Jeunehomme, F.; Hamm, B.

    2003-01-01

    Aim: To investigate the use of iodine-based contrast media in digital full-field mammography. Methods: After performing initial phantom studies, seven patients underwent digital mammography (Senographe 2000D, GE Medical Systems, Milwaukee, USA) using a specially filtered beam before as well as 60, 120, and 180 seconds after injection of 80 ml of iodine contrast medium (Ultravist 370, Schering AG, Germany). The precontrast mammograms were then subtracted from the postcontrast mammograms and the resulting images compared with a contrast-enhanced dynamic MRI study, performed on all women. Results: Contrast medium accumulation within the tumors was visualized with a good quality in all cases. The conditions under which successful contrast-enhanced digital mammography can be performed were determined in phantom studies. Conclusions: Contrast-enhanced digital mammography has a potential for improving the visualization of breast tumors in mammography using special beam filtering, adjusted X-ray parameters, proper timing, and suitable subtraction software. (orig.) [de

  16. Prevention of contrast-induced nephropathy by use of bicarbonate solution: preliminary results and literature review.

    Science.gov (United States)

    Silva, Ricardo Gonçalves da; Silva, Nelson Gonçalves da; Lucchesi, Fabiano; Burdmann, Emmanuel A

    2010-01-01

    The incidence of contrast-induced nephropathy has increased simultaneously with the increase in contrast medium use in diagnostic and interventional procedures. The incidence of contrast-induced nephropathy in the general population is low, but increases exponentially in patients with risk factors, such as diabetes and chronic kidney disease. Several strategies have been used in order to prevent contrast-induced nephropathy. The most efficient strategies are saline hydration (0.9% or 0.45%), use of low-or iso-osmolality contrast medium, and sodium bicarbonate infusion. The aim of this study was to review the pertinent literature and to assess the efficacy of hydration with 1.3% sodium bicarbonate compared with hydration with 0.9% saline solution in preventing contrast-induced nephropathy in high-risk patients. A systematic search of the literature was conducted in PubMed by using the following keywords: bicarbonate, nephropathy, contrast medium, and acute kidney failure. In addition, 27 patients with diabetes and/or chronic kidney disease, diagnosed with some kind of cancer were randomized for study. None of the patients developed contrast-induced nephropathy characterized as a 0.5 mg/ dL-increase and/or a relative 25%-increase in baseline creatinine. The literature review strongly suggested that sodium bicarbonate is effective in preventing contrast-induced nephropathy. Regarding the randomized study, saline solution and bicarbonate solution had similar efficacy in preventing contrast-induced nephropathy. However, the small number of patients does not allow definite conclusions.

  17. The Preinterventional Cystatin-Creatinine-Ratio: A Prognostic Marker for Contrast Medium-Induced Acute Kidney Injury and Long-Term All-Cause Mortality.

    Science.gov (United States)

    Lüders, Florian; Meyborg, Matthias; Malyar, Nasser; Reinecke, Holger

    2015-01-01

    Contrast medium-induced acute kidney injury (CI-AKI) is an important iatrogenic complication following the injection of iodinated contrast media. The level of serum creatinine (SCr) is the currently accepted 'gold standard' to diagnose CI-AKI. Cystatin C (CyC) has been detected as a more sensitive marker for renal dysfunction. Both have their limitations. The role of the preinterventional CyC-SCr ratio for evaluating the risk for CI-AKI and long-term all-cause mortality was retrospectively analyzed in the prospective single-center 'Dialysis-versus-Diuresis trial'. CI-AKI was defined and staged according to the Acute Kidney Injury Network classification. Three hundred and seventy-three patients were included (average age 67.4 ± 10.2 years, 16.4% women, 29.2% with diabetes mellitus, mean baseline glomerular filtration rate 56.3 ± 20.2 ml/min/1.73 m(2) [as estimated by Chronic Kidney Disease Epidemiology Collaboration Serum Creatinine Cystatin C equation], 5.1% ejection fraction high significant association between preinterventional CyC-SCr ratio and long-term all-cause mortality (mean follow-up 649 days, hazards ratio 4.096, 95% CI 1.625-10.329, p = 0.003). The preinterventional CyC-SCr ratio is independently associated with CI-AKI and highly significant associated with long-term mortality after heart catheterization. © 2015 S. Karger AG, Basel.

  18. Fragment-based approach to calculate hydrophobicity of anionic and nonionic surfactants from chromatographic retention on a C18 stationary phase

    NARCIS (Netherlands)

    Hammer, J.; Haftka, J.J.-H.; Scherpenisse, P.; Hermens, J.L.M.; de Voogt, P.W.P.

    To predict the fate and potential effects of organic contaminants, information about their hydrophobicity is required. However, common parameters to describe the hydrophobicity of organic compounds (e.g., octanol–water partition constant [KOW]) proved to be inadequate for ionic and nonionic

  19. Possibilities to reduce the effect of ionizing radiation by interaction of two types of radiation into a matter: ionized and non-ionized radiation

    International Nuclear Information System (INIS)

    Tanvir

    2007-01-01

    Full text: At present it has been accepted that ionized radiation can cause biological effects on the human body and the only way of preventing this effect, is by shielding the source of radiation by absorbing materials. On the other hand, the technology of non-ionizing radiation is upgraded. The canalization of radiation through the wave-guide based structures and optical fiber is well established. This reminds us that passing through benzene non-ionized radiation give the 'Raman' effect, which can ensure the secondary generation of non-ionized radiation with the wave length of nanometer and so far. These types of non-ionized radiation can easily be correlated with the gamma radiation, which is ionized. We know that high-energized photon usually interacts with matter and reduces its energy to the matter and generate electro-magnetic waves into the molecules of the matter. It is also well known that through the wave-guide based structures and optical fiber; the path of energy distribution of photon is likely to be optical energetic modes. If two types of photon from two types of radiation (ionized and non-ionized) interact with matter and pass through the optical fiber, they can generate optical modes with various wavelengths and phase velocities. With 'Raman' effect we can generate secondary electromagnetic waves of nanometer; as well as optical modes into the optical fiber. These optical modes from two types of radiation with various phase velocities, having the similar wavelength, can decrease or accelerate some modes. On the view of signal distribution, we can assume that if two similar signals pass through the circuit with phase difference 180P 0 P, then the result posses no signal. We are also reminded that photon of γ - radiation can spread from 0 deg. to 180 deg. C, where the 'Compton' loss of radiation is minimum. In view of the electro-magnetic theory of Maxwell we can assume the energetic field of optical modes, which are generated into the optical

  20. Prevention of contrast induced nephropathy with sodium bicarbonate (the PROMEC study

    Directory of Open Access Journals (Sweden)

    John Fredy Nieto-Ríos

    2014-09-01

    Full Text Available Introduction: Contrast-induced nephropathy is a common complication of radiographic procedures. Different measures have been used to avoid this damage, but the evidence is controversial. New investigations are required to clarify it. We investigated the efficacy and safety of sodium bicarbonate solution compared with sodium chloride solution to prevent contrast induced nephropathy in patients with or at risk of renal dysfunction. Methods: A prospective, single-center, randomized clinical trial conducted from May 1, 2007 to February 8, 2008. Inpatients in a tertiary center, scheduled to undergo a procedure with the nonionic radiographic contrast agent iohexol. There were 220 patients with serum creatinine levels of at least 1.2 mg/dL (106.1 µmol/L and/or type 2 diabetics, who were randomized to receive an infusion of sodium chloride (n = 113 or sodium bicarbonate (n = 107 before and after contrast dye administration. The intervention were "A" group received 1 ml/kg/hour of normal saline solution, starting 12 hours before and continuing 12 hours after iohexol contrast. "B" group received 3 ml/kg of sodium bicarbonate solution (150 mEq/L one hour prior to procedure and then drip rate was decreased to 1 ml/kg/hour until 6 hours post procedure. Our main outcome measure was change in serum creatinine. Results: The mean creatinine value after the procedure was 1.26 mg/dL in the saline group and 1.22 mg/dL in the bicarbonate group (mean difference: 0.036; CI 95%: -0.16 to 0.23, p = 0.865. The diagnosis of contrast-induced nephropathy, defined by increase in serum creatinine on 25% or more within 2 days after administration of radiographic contrast, was done in twelve patients (12% in the bicarbonate group and eighth patients (7.1% in the saline group (RR: 1.68, CI 95%: 0.72 to 3.94. Conclusion: Our investigation showed that there were no differences between normal saline solution (extended infusion vs. bicarbonate solution for nephroprotection.