WorldWideScience

Sample records for noninvasive electrocardiographic imaging

  1. Pediatric Electrocardiographic Imaging (ECGI) Applications

    Science.gov (United States)

    Silva, Jennifer N. A.

    2014-01-01

    Summary Noninvasive electrocardiographic imaging (ECGI) has been used in pediatric and congenital heart patients to better understand their electrophysiologic substrates. In this article we focus on the 4 subjects related to pediatric ECGI: 1) ECGI in patients with congenital heart disease and Wolff-Parkinson-White syndrome, 2) ECGI in patients with hypertrophic cardiomyopathy and pre-excitation, 3) ECGI in pediatric patients with Wolff-Parkinson-White syndrome, and 4) ECGI for pediatric cardiac resynchronization therapy. PMID:25722754

  2. Noninvasive imaging of experimental lung fibrosis.

    Science.gov (United States)

    Zhou, Yong; Chen, Huaping; Ambalavanan, Namasivayam; Liu, Gang; Antony, Veena B; Ding, Qiang; Nath, Hrudaya; Eary, Janet F; Thannickal, Victor J

    2015-07-01

    Small animal models of lung fibrosis are essential for unraveling the molecular mechanisms underlying human fibrotic lung diseases; additionally, they are useful for preclinical testing of candidate antifibrotic agents. The current end-point measures of experimental lung fibrosis involve labor-intensive histological and biochemical analyses. These measures fail to account for dynamic changes in the disease process in individual animals and are limited by the need for large numbers of animals for longitudinal studies. The emergence of noninvasive imaging technologies provides exciting opportunities to image lung fibrosis in live animals as often as needed and to longitudinally track the efficacy of novel antifibrotic compounds. Data obtained by noninvasive imaging provide complementary information to histological and biochemical measurements. In addition, the use of noninvasive imaging in animal studies reduces animal usage, thus satisfying animal welfare concerns. In this article, we review these new imaging modalities with the potential for evaluation of lung fibrosis in small animal models. Such techniques include micro-computed tomography (micro-CT), magnetic resonance imaging, positron emission tomography (PET), single photon emission computed tomography (SPECT), and multimodal imaging systems including PET/CT and SPECT/CT. It is anticipated that noninvasive imaging will be increasingly used in animal models of fibrosis to gain insights into disease pathogenesis and as preclinical tools to assess drug efficacy.

  3. Imaging the pancreas: from ex vivo to non-invasive technology

    DEFF Research Database (Denmark)

    Holmberg, D; Ahlgren, U

    2008-01-01

    While many recently published reviews have covered non-invasive nuclear imaging techniques, the aim of this review is to focus on current developments in optical imaging technologies for investigating the pancreas. Several of these modalities are being developed into non-invasive, real-time monit......While many recently published reviews have covered non-invasive nuclear imaging techniques, the aim of this review is to focus on current developments in optical imaging technologies for investigating the pancreas. Several of these modalities are being developed into non-invasive, real...

  4. Electrocardiographic left ventricular hypertrophy without echocardiographic abnormalities evaluated by myocardial perfusion and fatty acid metabolic imaging

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi

    2000-01-01

    The pathophysiologic process in patients with electrocardiographic left ventricular hypertrophy with ST, T changes but without echocardiographic abnormalities was investigated by myocardial perfusion imaging and fatty acid metabolic imaging. Exercise stress 99m Tc-methoxy-isobutyl isonitrile (MIBI) imaging and rest 123 I-beta-methyl-p-iodophenyl pentadecanoic acid (BMIPP) imaging were performed in 59 patients with electrocardiographic hypertrophy including 29 without apparent cause including hypertension and echocardiographic hypertrophy, and 30 with essential hypertension. Coronary angiography was performed in 6 patients without hypertension and 4 with hypertension and biopsy specimens were obtained from the left ventricular apex from 6 patients without hypertension. Myocardial perfusion and 123 I-BMIPP images were classified into 3 types: normal, increased accumulation of the isotope at the left ventricular apex (high uptake) and defect. Transient perfusion abnormality and apical defect observed by 123 I-BMIPP imaging were more frequent in patients without hypertension than in patients with hypertension (32% vs. 17%, p=0.04671 in perfusion; 62% vs. 30%, p=0.0236 in 123 I-BMIPP). Eighteen normotensive patients with apical defect by 123 I-BMIPP imaging included 3 of 10 patients with normal perfusion at exercise, 6 of 10 patients with high uptake and 9 of 9 patients with perfusion defect. The defect size revealed by 123 I-BMIPP imaging was greater than that of the perfusion abnormality. Coronary stenoses were not observed and myocardial specimens showed myocardial disarray with hypertrophy. Moreover, 9 patients with hypertension and apical defects by 123 I-BMIPP showed 3 different types of perfusion. Many patients without hypertension show a pathologic process similar to hypertrophic cardiomyopathy. Perfusion and 123 I-BMIPP imaging are useful for the identification of these patients. (author)

  5. Electrocardiographic findings related to aging

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Shoichi; Yano, Katsuhiko

    1962-12-12

    More than 3000 electrocardiographic tracings for the ABCC-JNIH Adult Health Study Sample were studied to detect any specific abnormalities or nonspecific age changes in relation to possible radiation effects upon the cardiovascular system. The 4 comparison groups were studied with respect to the prevalence of electrocardiographic abnormalities and an electrocardiographic aging index which was defined to evaluate physiological change with age. Statistically significant differences were observed in the following aspects: In males aged 50 to 59, the prevalence of major electrocardiographic abnormalities was highest in the group located nearest the hypocenter. This was not observed in other age groups. In females, the prevalence of QRS high voltage was highest in Group 2 but low in Group 1. This trend was consistent in all age groups. These findings were not fully accounted for by differences in blood pressure, heart size, body weight or serum cholesterol values. In the age trend curve of the electrocardiographic aging index, a difference was observed among comparison groups in both sexes. This difference in electrocardiographic aging index is mainly attributed to T/sub I/ amplitude for males and R/sub II/ amplitude and QRS axis for females. Interpretation of these findings is rather difficult since very little has been known about radiation effects upon the cardiovascular system in humans. Further intensive studies are desired on the basis of the clues suggested in this report. 16 references, 3 figures, 31 tables.

  6. Electrocardiographic gating in positron emission computed tomography

    International Nuclear Information System (INIS)

    Hoffman, E.J.; Phelps, M.E.; Wisenberg, G.; Schelbert, H.R.; Kuhl, D.E.

    1979-01-01

    Electrocardiographic (ECG) synchronized multiple gated data acquisition was employed with positron emission computed tomography (ECT) to obtain images of myocardial blood pool and myocardium. The feasibility and requirements of multiple gated data acquisition in positron ECT were investigated for 13NH3, ( 18 F)-2-fluoro-2-D-deoxyglucose, and ( 11 C)-carboxyhemoglobin. Examples are shown in which image detail is enhanced and image interpretation is facilitated when ECG gating is employed in the data collection. Analysis of count rate data from a series of volunteers indicates that multiple, statistically adequate images can be obtained under a multiple gated data collection format without an increase in administered dose

  7. RTOS kernel in portable electrocardiograph

    Science.gov (United States)

    Centeno, C. A.; Voos, J. A.; Riva, G. G.; Zerbini, C.; Gonzalez, E. A.

    2011-12-01

    This paper presents the use of a Real Time Operating System (RTOS) on a portable electrocardiograph based on a microcontroller platform. All medical device digital functions are performed by the microcontroller. The electrocardiograph CPU is based on the 18F4550 microcontroller, in which an uCOS-II RTOS can be embedded. The decision associated with the kernel use is based on its benefits, the license for educational use and its intrinsic time control and peripherals management. The feasibility of its use on the electrocardiograph is evaluated based on the minimum memory requirements due to the kernel structure. The kernel's own tools were used for time estimation and evaluation of resources used by each process. After this feasibility analysis, the migration from cyclic code to a structure based on separate processes or tasks able to synchronize events is used; resulting in an electrocardiograph running on one Central Processing Unit (CPU) based on RTOS.

  8. RTOS kernel in portable electrocardiograph

    International Nuclear Information System (INIS)

    Centeno, C A; Voos, J A; Riva, G G; Zerbini, C; Gonzalez, E A

    2011-01-01

    This paper presents the use of a Real Time Operating System (RTOS) on a portable electrocardiograph based on a microcontroller platform. All medical device digital functions are performed by the microcontroller. The electrocardiograph CPU is based on the 18F4550 microcontroller, in which an uCOS-II RTOS can be embedded. The decision associated with the kernel use is based on its benefits, the license for educational use and its intrinsic time control and peripherals management. The feasibility of its use on the electrocardiograph is evaluated based on the minimum memory requirements due to the kernel structure. The kernel's own tools were used for time estimation and evaluation of resources used by each process. After this feasibility analysis, the migration from cyclic code to a structure based on separate processes or tasks able to synchronize events is used; resulting in an electrocardiograph running on one Central Processing Unit (CPU) based on RTOS.

  9. Non-invasive assessment of the liver using imaging

    Science.gov (United States)

    Thorling Thompson, Camilla; Wang, Haolu; Liu, Xin; Liang, Xiaowen; Crawford, Darrell H.; Roberts, Michael S.

    2016-12-01

    Chronic liver disease causes 2,000 deaths in Australia per year and early diagnosis is crucial to avoid progression to cirrhosis and end stage liver disease. There is no ideal method to evaluate liver function. Blood tests and liver biopsies provide spot examinations and are unable to track changes in function quickly. Therefore better techniques are needed. Non-invasive imaging has the potential to extract increased information over a large sampling area, continuously tracking dynamic changes in liver function. This project aimed to study the ability of three imaging techniques, multiphoton and fluorescence lifetime imaging microscopy, infrared thermography and photoacoustic imaging, in measuring liver function. Collagen deposition was obvious in multiphoton and fluorescence lifetime imaging in fibrosis and cirrhosis and comparable to conventional histology. Infrared thermography revealed a significantly increased liver temperature in hepatocellular carcinoma. In addition, multiphoton and fluorescence lifetime imaging and photoacoustic imaging could both track uptake and excretion of indocyanine green in rat liver. These results prove that non-invasive imaging can extract crucial information about the liver continuously over time and has the potential to be translated into clinic in the assessment of liver disease.

  10. Noninvasive imaging of breast cancer

    International Nuclear Information System (INIS)

    Medarova, Z.

    2009-01-01

    With the development of molecularly targeted cancer therapies, it is highly advantageous to be able to determine their efficacy, to improve overall patient survival. Non-invasive imaging techniques are currently available for visualizing different pathological conditions of the human body, but their use for cancer monitoring is limited due to the lack of tumor-specific imaging probes. This review will attempt to summarize the current clinical diagnostic approaches for breast cancer detection, staging, and therapy assessment. In addition, I will present some novel concepts from the field of molecular imaging that form the basis of some of our research. We believe that this general imaging strategy has the potential of significantly advancing our ability to diagnose breast cancer at the earliest stages of the pathology, before any overt clinical symptoms have developed, as well as to better direct the development of molecularly-targeted individualized therapy protocols.

  11. Non-invasive imaging for studying anti-angiogenic therapy effects

    NARCIS (Netherlands)

    Ehling, J.; Lammers, Twan Gerardus Gertudis Maria; Kiessling, F.

    2013-01-01

    Noninvasive imaging plays an emerging role in preclinical and clinical cancer research and has high potential to improve clinical translation of new drugs. This article summarises and discusses tools and methods to image tumour angiogenesis and monitor anti-angiogenic therapy effects. In this

  12. Noninvasive imaging of hepatocellular carcinoma: From diagnosis to prognosis

    Science.gov (United States)

    Jiang, Han-Yu; Chen, Jie; Xia, Chun-Chao; Cao, Li-Kun; Duan, Ting; Song, Bin

    2018-01-01

    Hepatocellular carcinoma (HCC) is the most common primary liver cancer and a major public health problem worldwide. Hepatocarcinogenesis is a complex multistep process at molecular, cellular, and histologic levels with key alterations that can be revealed by noninvasive imaging modalities. Therefore, imaging techniques play pivotal roles in the detection, characterization, staging, surveillance, and prognosis evaluation of HCC. Currently, ultrasound is the first-line imaging modality for screening and surveillance purposes. While based on conclusive enhancement patterns comprising arterial phase hyperenhancement and portal venous and/or delayed phase wash-out, contrast enhanced dynamic computed tomography and magnetic resonance imaging (MRI) are the diagnostic tools for HCC without requirements for histopathologic confirmation. Functional MRI techniques, including diffusion-weighted imaging, MRI with hepatobiliary contrast agents, perfusion imaging, and magnetic resonance elastography, show promise in providing further important information regarding tumor biological behaviors. In addition, evaluation of tumor imaging characteristics, including nodule size, margin, number, vascular invasion, and growth patterns, allows preoperative prediction of tumor microvascular invasion and patient prognosis. Therefore, the aim of this article is to review the current state-of-the-art and recent advances in the comprehensive noninvasive imaging evaluation of HCC. We also provide the basic key concepts of HCC development and an overview of the current practice guidelines. PMID:29904242

  13. Electrocardiographic changes in obstructive sleep apnea syndrome.

    Science.gov (United States)

    Prakasa, Kalpana; Ahmed, Jehanara; Hasan, Syed; Yousef, Mahmoud; Shridharani, Sachin

    2005-01-01

    The acute electrocardiographic changes during apneic episodes in patients with sleep apnea are well known. Long-term electro-cardiographic changes in these patients are not well studied. We conducted a retrospective case-control study to assess the electrocardiographic changes in African-American patients with established obstructive sleep apnea syndrome (OSA). A significant percentage of patients with OSA had abnormal EKGs as compared to the control group. The effect of sleep apnea on the cardiovascular system is more complex in African-Americans due to higher prevalence of co-morbid conditions. Seventy-three percent of our patients with OSA had metabolic syndrome.

  14. Diagnostic and prognostic value of non-invasive imaging in known or suspected coronary artery disease

    International Nuclear Information System (INIS)

    Schuijf, J.D.; Poldermans, D.; Shaw, L.J.; Jukema, J.W.; Wall, E.E. van der; Lamb, H.J.; Roos, A. de; Wijns, W.; Bax, J.J.

    2006-01-01

    The role of non-invasive imaging techniques in the evaluation of patients with suspected or known coronary artery disease (CAD) has increased exponentially over the past decade. The traditionally available imaging modalities, including nuclear imaging, stress echocardiography and magnetic resonance imaging (MRI), have relied on detection of CAD by visualisation of its functional consequences (i.e. ischaemia). However, extensive research is being invested in the development of non-invasive anatomical imaging using computed tomography or MRI to allow detection of (significant) atherosclerosis, eventually at a preclinical stage. In addition to establishing the presence of or excluding CAD, identification of patients at high risk for cardiac events is of paramount importance to determine post-test management, and the majority of non-invasive imaging tests can also be used for this purpose. The aim of this review is to provide an overview of the available non-invasive imaging modalities and their merits for the diagnostic and prognostic work-up in patients with suspected or known CAD. (orig.)

  15. Prediction of single versus multivessel disease following myocardial infarction using 201-thallium scintigraphy and electrocardiographic stress testing

    International Nuclear Information System (INIS)

    Weiss, R.J.; Morise, A.P.; Raabe, D.S. Jr.; Sbarbaro, J.A.

    1983-01-01

    Fifty patients were evaluated who suffered a single myocardial infarction with graded electrocardiographic stress testing, 201-thallium myocardial perfusion imaging and coronary angiography to assess the role of noninvasive indices as predictors of single versus multivessel coronary artery disease. Multivessel involvement was defined angiographically as the presence of two or more major coronary arteries with at least a 70% intraluminal diameter narrowing. Multivessel disease was defined scintigraphically as the presence of stress and/or redistribution perfusion defects in the distribution of more than one coronary artery. The results of stress electrocardiography were not useful in differentiating patients with single (9/16 positive) versus multivessel (22/34 positive) disease. The degree of exercise-induced ST-segment depression was also not helpful. Stress 201-thallium imaging did offer limited additional information with correct predictions of multivessel disease in 21 of 26 patients. Predictions of single-vessel disease were accurate in 11 of 24 patients. Eleven of these 13 incorrect predictions of single-vessel disease were due to the relative insensitivity of the thallium stress image to perceive defect in the anterior wall when the left anterior descending artery had significant obstruction at catheterization. Further refinements of stress perfusion imaging are needed before this method can be used to reliably separate patients with single and multivessel disease after myocardial infarction

  16. Quantitative evaluations of left ventricular function obtained by electrocardiographically-gated magnetic resonance imaging

    International Nuclear Information System (INIS)

    Takeda, Tohru; Iida, Kaname; Sugishita, Yasuro; Anno, Izumi; Akisada, Masayoshi; Matsuda, Mitsuo; Akatsuka, Takao; Koseki, Susumu.

    1989-01-01

    Using electrocardiographically-gated magnetic resonance imaging, regional cardiac function was evaluated in 12 normal volunteers and in 10 cases of old myocardial infarction. The optimal short axis of the left ventricle was selected at the chordae tendineae level. The left ventricle was divided into 12 segments using a computer-aided system, and percentile shortening fraction (%SF) and percentile wall thickening (%WT) were calculated in each segment by the fixed coordinate method. In the normal volunteers, heterogeneity of both %FS and %WT was observed, ranging from 25±13% and 37±13%, respectively in the septal segment, to 49±13% and 60±21%, respectively in the posterior segment. In the cases of myocardial infarction, decreased %FS and %WT were detected at the affected regions. The abnormal regions revealed by %WT tended to be narrower than those revealed by %FS. Thus the MR technique at the optimal axis may be useful for quantitative evaluations of regional cardiac function. (author)

  17. Electrophysiological mechanisms of the SI SII SIII electrocardiographic morphology

    International Nuclear Information System (INIS)

    Bayes de Luna, A.; Carrio, I.; Subirana, M.T.; Torner, P.; Cosin, J.; Sagues, F.; Guindo, J.

    1987-01-01

    We studied three groups of individuals by means of spatial-velocity electrocardiograms and thallium-201 myocardial imaging to figure out the electrophysiological explanation of the SI SII SIII electrocardiographic morphology. We studied twelve healthy individuals without SI SII SIII, seven healthy individuals with SI SII SIII and fifteen patients with chronic obstructive pulmonary disease with SI SII SIII. The average values of the QRS-E and QRS-F intervals were higher in the second and third groups than in the first. One patient of the second group and thirteen of the third showed right ventricular enlargement. The slowing down of the right ventricular conduction explained the SI SII SIII morphology in normal individuals in more than half the cases. In patients with chronic obstructive pulmonary disease with SI SII SIII the conduction delay plays an important part in the electrogenesis of the right ventricular enlargement electrocardiographic morphology. We think that these observations can give further data about the electrophysiologic mechanism of the SI SII SIII morphology

  18. Non-invasive imaging using reporter genes altering cellular water permeability

    Science.gov (United States)

    Mukherjee, Arnab; Wu, Di; Davis, Hunter C.; Shapiro, Mikhail G.

    2016-12-01

    Non-invasive imaging of gene expression in live, optically opaque animals is important for multiple applications, including monitoring of genetic circuits and tracking of cell-based therapeutics. Magnetic resonance imaging (MRI) could enable such monitoring with high spatiotemporal resolution. However, existing MRI reporter genes based on metalloproteins or chemical exchange probes are limited by their reliance on metals or relatively low sensitivity. Here we introduce a new class of MRI reporters based on the human water channel aquaporin 1. We show that aquaporin overexpression produces contrast in diffusion-weighted MRI by increasing tissue water diffusivity without affecting viability. Low aquaporin levels or mixed populations comprising as few as 10% aquaporin-expressing cells are sufficient to produce MRI contrast. We characterize this new contrast mechanism through experiments and simulations, and demonstrate its utility in vivo by imaging gene expression in tumours. Our results establish an alternative class of sensitive, metal-free reporter genes for non-invasive imaging.

  19. (19)F-heptuloses as tools for the non-invasive imaging of GLUT2-expressing cells

    DEFF Research Database (Denmark)

    Malaisse, Willy J; Zhang, Ying; Louchami, Karim

    2012-01-01

    Suitable analogs of d-mannoheptulose are currently considered as possible tools for the non-invasive imaging of pancreatic islet insulin-producing cells. Here, we examined whether (19)F-heptuloses could be used for non-invasive imaging of GLUT2-expressing cells. After 20 min incubation, the uptake......-mannoheptulose in inhibiting insulin release. The 1-deoxy-1-fluoro-d-mannoheptulose and 3-deoxy-3-fluoro-d-mannoheptulose only marginally affected INS-1 cell viability. These findings are compatible with the view that selected (19)F-heptuloses may represent suitable tools for the non-invasive imaging of hepatocytes...

  20. Non-invasive imaging of kupffer cell status using radiolabelled mannosylated albumin

    NARCIS (Netherlands)

    Mahajan, V.; Hartimath, S.; Comley, R.; Stefan-Gueldner, M.; Roth, A.; Poelstra, K.; Reker-Smit, C.; Kamps, J.; Dierckx, R.; de Vries, Erik

    2014-01-01

    Background and Aims: Kupffer cells are responsible for maintaining liver homeostasis and have a vital role in chronic hepatotoxicity and various liver diseases. Positron Imaging Tomography (PET) is a non-invasive imaging technique that allows quantification and visualization of biochemical processes

  1. 5th German cardiodiagnostic meeting 2013 with the 6th Leipzig Symposium on non-invasive cardiovascular imaging. Challenges and limit of the non-invasive cardiac imaging

    International Nuclear Information System (INIS)

    2013-01-01

    The proceedings on the German cardiodiagnostic meeting 2013 together with the 6th Leipzig Symposium on non-invasive cardiovascular imaging include abstracts concerning the following topics: Imaging in the rhythmology; adults with congenital cardiac defects; cardiac myopathies - myocarditis; cardiac valves (before and after transcutaneous valve replacement); coronary heart diseases; technical developments.

  2. Non-invasive terahertz field imaging inside parallel plate waveguides

    DEFF Research Database (Denmark)

    Iwaszczuk, Krzysztof; Andryieuski, Andrei; Lavrinenko, Andrei

    2011-01-01

    We present a non-invasive broadband air photonic method of imaging of the electric field of THz pulses propagating inside a tapered parallel plate waveguide. The method is based on field-enhanced second harmonic generation of the fundamental laser beam in an external electric field. We apply...

  3. Electrocardiographic Findings in Brazilian Adults without Heart Disease: ELSA-Brasil.

    Science.gov (United States)

    Pinto, Marcelo Martins; Brant, Luisa C C; Padilha-da-Silva, José Luiz; Foppa, Murilo; Lotufo, Paulo A; Mill, José Geraldo; Vasconcelo-Silva, Paulo R; Almeida, Maria da Conceição C; Barreto, Sandhi Maria; Ribeiro, Antônio Luiz Pinho

    2017-11-01

    The electrocardiogram (ECG) is widely used in population-based studies. However, there are few studies on electrocardiographic findings in Latin America and in Brazil. The Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) comprised 15,105 participants (35-74 years) from six Brazilian capitals. To describe electrocardiographic findings in Brazilian adults without heart disease, stratified by sex, age and race/skin color. Cross-sectional study with baseline data of 11,094 adults (44.5% men) without heart disease from ELSA-Brasil. The ECGs were recorded with the Burdick Atria 6100 machine and stored at the Pyramis System. ECG analysis was automatically performed using the Glasgow University software. A descriptive analysis of heart rate (HR), P, QRS and T waves' duration, PR and QT intervals, and P, R and T axes was performed. After stratification by sex, race/color and age, the groups were compared by the Wilcoxon and Kruskal-Wallis test at a significance level of 5%. Linear regression models were used to evaluate the behavior of electrocardiographic parameters over age. Major electrocardiographic abnormalities defined by the Minnesota code were manually revised. Medians values of the electrocardiographic parameters were different between men and women: HR 63 vs. 66 bpm, PR 164 vs.158 ms, QT corrected 410 vs. 421 ms, QRS duration 92 vs. 86 ms, P-wave duration 112 vs. 108 ms, P-wave axis 54 vs. 57 degrees, R-wave axis 35 vs. 39 degrees, T-wave axis 39 vs. 45 degrees (p < 0.001 for all). The 2nd and the 98th percentiles of each variable were also obtained, and graphs were constructed to illustrate the behavior of the electrocardiographic findings over age of participants stratified by sex and race/skin color. The values for the electrocardiographic measurements herein described can be used as reference for Brazilian adults free of heart disease, stratified by sex. Our results suggest that self-reported race/skin color have no significant influence on

  4. An Image Registration Based Technique for Noninvasive Vascular Elastography

    OpenAIRE

    Valizadeh, Sina; Makkiabadi, Bahador; Mirbagheri, Alireza; Soozande, Mehdi; Manwar, Rayyan; Mozaffarzadeh, Moein; Nasiriavanaki, Mohammadreza

    2018-01-01

    Non-invasive vascular elastography is an emerging technique in vascular tissue imaging. During the past decades, several techniques have been suggested to estimate the tissue elasticity by measuring the displacement of the Carotid vessel wall. Cross correlation-based methods are the most prevalent approaches to measure the strain exerted in the wall vessel by the blood pressure. In the case of a low pressure, the displacement is too small to be apparent in ultrasound imaging, especially in th...

  5. 2017 multimodality appropriate use criteria for noninvasive cardiac imaging: Export consensus of the Asian society of cardiovascular imaging

    Energy Technology Data Exchange (ETDEWEB)

    Beck, Kyong Min Sarah [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Kim, Jeong A [Dept. of Radiology, Ilsan Paik Hospital, Inje University College of Medicine, Goyang (Korea, Republic of); Choe, Yeon Hyeon [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); and others

    2017-11-15

    In 2010, the Asian Society of Cardiovascular Imaging (ASCI) provided recommendations for cardiac CT and MRI, and this document reflects an update of the 2010 ASCI appropriate use criteria (AUC). In 2016, the ASCI formed a new working group for revision of AUC for noninvasive cardiac imaging. A major change that we made in this document is the rating of various noninvasive tests (exercise electrocardiogram, echocardiography, positron emission tomography, single-photon emission computed tomography, radionuclide imaging, cardiac magnetic resonance, and cardiac computed tomography/angiography), compared side by side for their applications in various clinical scenarios. Ninety-five clinical scenarios were developed from eight selected pre-existing guidelines and classified into four sections as follows: 1) detection of coronary artery disease, symptomatic or asymptomatic; 2) cardiac evaluation in various clinical scenarios; 3) use of imaging modality according to prior testing; and 4) evaluation of cardiac structure and function. The clinical scenarios were scored by a separate rating committee on a scale of 1–9 to designate appropriate use, uncertain use, or inappropriate use according to a modified Delphi method. Overall, the AUC ratings for CT were higher than those of previous guidelines. These new AUC provide guidance for clinicians choosing among available testing modalities for various cardiac diseases and are also unique, given that most previous AUC for noninvasive imaging include only one imaging technique. As cardiac imaging is multimodal in nature, we believe that these AUC will be more useful for clinical decision making.

  6. Hypokalemia-induced pseudoischemic electrocardiographic changes and quadriplegia.

    Science.gov (United States)

    Mirijello, Antonio; Rinninella, Emanuele; De Leva, Francesca; Tosoni, Alberto; Vassallo, Gabriele; Antonelli, Mariangela; Addolorato, Giovanni; Landolfi, Raffaele

    2014-03-01

    Hypokalemia is a common biochemical abnormality. Severe hypokalemia can produce cardiac rhythm alterations and neurologic manifestations. Early detection and treatment allow clinician to prevent morbidity and mortality from cardiac arrhythmias and respiratory failure. Here, we describe a case of severe hypokalemia inducing pseudoischemic electrocardiographic (ECG) alterations and quadriplegia, in a patient affected by chronic diarrhea. Electrocardiographic alterations and neurologic manifestations completely disappeared after potassium replacement; however, prolonged potassium supplementation was required to achieve the normalization of plasmatic potassium levels. Consecutive figures show ECG improvement until normalization of ECG findings.

  7. Non-invasive imaging of plant roots in different soils using magnetic resonance imaging (MRI

    Directory of Open Access Journals (Sweden)

    Daniel Pflugfelder

    2017-11-01

    Full Text Available Abstract Background Root systems are highly plastic and adapt according to their soil environment. Studying the particular influence of soils on root development necessitates the adaptation and evaluation of imaging methods for multiple substrates. Non-invasive 3D root images in soil can be obtained using magnetic resonance imaging (MRI. Not all substrates, however, are suitable for MRI. Using barley as a model plant we investigated the achievable image quality and the suitability for root phenotyping of six commercially available natural soil substrates of commonly occurring soil textures. The results are compared with two artificially composed substrates previously documented for MRI root imaging. Results In five out of the eight tested substrates, barley lateral roots with diameters below 300 µm could still be resolved. In two other soils, only the thicker barley seminal roots were detectable. For these two substrates the minimal detectable root diameter was between 400 and 500 µm. Only one soil did not allow imaging of the roots with MRI. In the artificially composed substrates, soil moisture above 70% of the maximal water holding capacity (WHCmax impeded root imaging. For the natural soil substrates, soil moisture had no effect on MRI root image quality in the investigated range of 50–80% WHCmax. Conclusions Almost all tested natural soil substrates allowed for root imaging using MRI. Half of these substrates resulted in root images comparable to our current lab standard substrate, allowing root detection down to a diameter of 300 µm. These soils were used as supplied by the vendor and, in particular, removal of ferromagnetic particles was not necessary. With the characterization of different soils, investigations such as trait stability across substrates are now possible using noninvasive MRI.

  8. Evaluation on the influence of electrocardiograph modulated milliampere on image quality and exposure dosage of volume CT heart scan

    International Nuclear Information System (INIS)

    Zhang Sen; Du Xiangke; Li Jianyin

    2006-01-01

    Objective: To find out whether the use of ECG modulated current (mA) will influence image quality and to decide whether the electrocardiograph (ECG) modulated mA will effectively reduce the exposure dosage. Methods: The cardiac pulsating phantom was set at three speed levels, i.e. high, medium, and low speed so as to simulate different heart rates. The phantom was scanned with ECG modulated mA turned on and off, and the exposure dosage of each scan sequence was documented. The images were reconstructed with reconstruction algorithm that matched the different levels of heart rate. CT values and their corresponding standard deviations at uniform areas on the images and the variation of the CT values at different locations were measured. The results from the two groups with and without ECG modulated mA were analyzed. Results: Under the same level of heart rate, the exposure dosage was remarkably reduced when the ECG modulated mA was on than when it was off. Statistical analysis showed no significant difference (P>0.05) between the images from the two groups. Conclusion: When scanning the heart with volume CT (VCT), the application of ECG modulated mA can effectively reduce the exposure dosage without sacrificing the image quality. (authors)

  9. Dose reduction using prospective electrocardiograph-triggered axial coronary scan on the 64-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Yanyan; Wu Guogeng; Zhou Cheng; Gao Jianhua; Jiao Sheng; Cao Huizhi

    2008-01-01

    Objective: To compare radiation dose and image quality between prospective electrocardiograph (ECG)-triggered axial scan and retrospective ECG-gated helical scan in coronary 64-slice CT angiography (CTA). Methods: Seventy-seven consecutive patients [group A. Average body mass index (BMI): 24.6, heart rate 0.05). Conclusion: Prospective ECG-triggered axial scan in 64-slice coronary CTA can significantly reduce radiation exposure and the image quality can fulfill clinical diagnostic needs. (authors)

  10. Non-Invasive in vivo Imaging in Small Animal Research

    Directory of Open Access Journals (Sweden)

    V. Koo

    2006-01-01

    Full Text Available Non-invasive real time in vivo molecular imaging in small animal models has become the essential bridge between in vitro data and their translation into clinical applications. The tremendous development and technological progress, such as tumour modelling, monitoring of tumour growth and detection of metastasis, has facilitated translational drug development. This has added to our knowledge on carcinogenesis. The modalities that are commonly used include Magnetic Resonance Imaging (MRI, Computed Tomography (CT, Positron Emission Tomography (PET, bioluminescence imaging, fluorescence imaging and multi-modality imaging systems. The ability to obtain multiple images longitudinally provides reliable information whilst reducing animal numbers. As yet there is no one modality that is ideal for all experimental studies. This review outlines the instrumentation available together with corresponding applications reported in the literature with particular emphasis on cancer research. Advantages and limitations to current imaging technology are discussed and the issues concerning small animal care during imaging are highlighted.

  11. Magnetic resonance imaging based noninvasive measurements of brain hemodynamics in neonates

    DEFF Research Database (Denmark)

    De Vis, Jill B; Alderliesten, Thomas; Hendrikse, Jeroen

    2016-01-01

    Perinatal disturbances of brain hemodynamics can have a detrimental effect on the brain's parenchyma with consequently adverse neurodevelopmental outcome. Noninvasive, reliable tools to evaluate the neonate's brain hemodynamics are scarce. Advances in magnetic resonance imaging have provided new...

  12. Noninvasive three-dimensional live imaging methodology for the spindles at meiosis and mitosis

    Science.gov (United States)

    Zheng, Jing-gao; Huo, Tiancheng; Tian, Ning; Chen, Tianyuan; Wang, Chengming; Zhang, Ning; Zhao, Fengying; Lu, Danyu; Chen, Dieyan; Ma, Wanyun; Sun, Jia-lin; Xue, Ping

    2013-05-01

    The spindle plays a crucial role in normal chromosome alignment and segregation during meiosis and mitosis. Studying spindles in living cells noninvasively is of great value in assisted reproduction technology (ART). Here, we present a novel spindle imaging methodology, full-field optical coherence tomography (FF-OCT). Without any dye labeling and fixation, we demonstrate the first successful application of FF-OCT to noninvasive three-dimensional (3-D) live imaging of the meiotic spindles within the mouse living oocytes at metaphase II as well as the mitotic spindles in the living zygotes at metaphase and telophase. By post-processing of the 3-D dataset obtained with FF-OCT, the important morphological and spatial parameters of the spindles, such as short and long axes, spatial localization, and the angle of meiotic spindle deviation from the first polar body in the oocyte were precisely measured with the spatial resolution of 0.7 μm. Our results reveal the potential of FF-OCT as an imaging tool capable of noninvasive 3-D live morphological analysis for spindles, which might be useful to ART related procedures and many other spindle related studies.

  13. Electrophysiological Source Imaging: A Noninvasive Window to Brain Dynamics.

    Science.gov (United States)

    He, Bin; Sohrabpour, Abbas; Brown, Emery; Liu, Zhongming

    2018-06-04

    Brain activity and connectivity are distributed in the three-dimensional space and evolve in time. It is important to image brain dynamics with high spatial and temporal resolution. Electroencephalography (EEG) and magnetoencephalography (MEG) are noninvasive measurements associated with complex neural activations and interactions that encode brain functions. Electrophysiological source imaging estimates the underlying brain electrical sources from EEG and MEG measurements. It offers increasingly improved spatial resolution and intrinsically high temporal resolution for imaging large-scale brain activity and connectivity on a wide range of timescales. Integration of electrophysiological source imaging and functional magnetic resonance imaging could further enhance spatiotemporal resolution and specificity to an extent that is not attainable with either technique alone. We review methodological developments in electrophysiological source imaging over the past three decades and envision its future advancement into a powerful functional neuroimaging technology for basic and clinical neuroscience applications.

  14. Cardiovascular dysfunction in obesity and new diagnostic imaging techniques: the role of noninvasive image methods.

    Science.gov (United States)

    Barbosa, José Augusto A; Rodrigues, Alexandre B; Mota, Cleonice Carvalho C; Barbosa, Márcia M; Simões e Silva, Ana C

    2011-01-01

    Obesity is a major public health problem affecting adults and children in both developed and developing countries. This condition often leads to metabolic syndrome, which increases the risk of cardiovascular disease. A large number of studies have been carried out to understand the pathogenesis of cardiovascular dysfunction in obese patients. Endothelial dysfunction plays a key role in the progression of atherosclerosis and the development of coronary artery disease, hypertension and congestive heart failure. Noninvasive methods in the field of cardiovascular imaging, such as measuring intima-media thickness, flow-mediated dilatation, tissue Doppler, and strain, and strain rate, constitute new tools for the early detection of cardiac and vascular dysfunction. These techniques will certainly enable a better evaluation of initial cardiovascular injury and allow the correct, timely management of obese patients. The present review summarizes the main aspects of cardiovascular dysfunction in obesity and discusses the application of recent noninvasive imaging methods for the early detection of cardiovascular alterations.

  15. Frequency of electrocardiographic abnormalities in patients with psoriasis

    DEFF Research Database (Denmark)

    Hansen, Peter Riis; Juhl, Christian Rimer; Isaksen, Jonas Lynggaard

    2018-01-01

    Psoriasis is a chronic inflammatory disease associated with cardiovascular disease, for example, myocardial infarction, stroke, cardiovascular death, and arrhythmias. The resting electrocardiogram may carry prognostic information, but limited evidence is available of electrocardiographic findings...... beats/min, p = 0.007), but not after adjustment for smoking and body mass index. All other examined electrocardiographic variables, including QT interval corrected for heart rate with the Fridericia formula, PR interval, QRS duration, R axis, P-wave duration in lead V1, P-terminal force, J point...

  16. Development of an X-ray Computed Tomography System for Non-Invasive Imaging of Industrial Materials

    International Nuclear Information System (INIS)

    Abdullah, J.; Sipaun, S. M.; Mustapha, I.; Zain, R. M.; Rahman, M. F. A.; Mustapha, M.; Shaari, M. R.; Hassan, H.; Said, M. K. M.; Mohamad, G. H. P.; Ibrahim, M. M.

    2008-01-01

    X-ray computed tomography is a powerful non-invasive imaging technique for viewing an object's inner structures in two-dimensional cross-section images without the need to physically section it. The invention of CT techniques revolutionised the field of medical diagnostic imaging because it provided more detailed and useful information than any previous non-invasive imaging techniques. The method is increasingly being used in industry, aerospace, geosciences and archaeology. This paper describes the development of an X-ray computed tomography system for imaging of industrial materials. The theoretical aspects of CT scanner, the system configurations and the adopted algorithm for image reconstruction are discussed. The penetrating rays from a 160 kV industrial X-ray machine were used to investigate structures that manifest in a manufactured component or product. Some results were presented in this paper

  17. Muscle perfusion and metabolic heterogeneity: insights from noninvasive imaging techniques

    DEFF Research Database (Denmark)

    Kalliokoski, Kari K; Scheede-Bergdahl, Celena; Kjaer, Michael

    2006-01-01

    Recent developments in noninvasive imaging techniques have enabled the study of local changes in perfusion and metabolism in skeletal muscle as well as patterns of heterogeneity in these variables in humans. In this review, the principles of these techniques along with some recent findings...... on functional heterogeneity in human skeletal muscle will be presented....

  18. In-situ Non-Invasive Imaging of Liquid-Immersed Thin Film Composite Membranes

    KAUST Repository

    Ogieglo, Wojciech; Pinnau, Ingo; Wessling, Matthias

    2017-01-01

    We present a non-invasive method to directly image liquid-immersed thin film composite membranes. The approach allows accessing information not only on the lateral distribution of the coating thickness, including variations in its swelling

  19. Noninvasive imaging of three-dimensional cardiac activation sequence during pacing and ventricular tachycardia.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-08-01

    Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. This study sought to rigorously assess the imaging performance of a 3-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of 3D intracardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE)-induced ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in 13 healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computed tomography images were obtained to construct geometry models. The noninvasively imaged activation sequence correlated well with invasively measured counterpart, with a correlation coefficient of 0.72 ± 0.04, and a relative error of 0.30 ± 0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from the imaged site of initial activation to the pacing site or site of arrhythmias determined from intracardiac mapping was ∼5 mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. 3DCEI can noninvasively delineate important features of focal or multifocal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequences of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  20. A review of non-invasive imaging methods and applications in contaminant hydrogeology research.

    Science.gov (United States)

    Werth, Charles J; Zhang, Changyong; Brusseau, Mark L; Oostrom, Mart; Baumann, Thomas

    2010-04-01

    Contaminant hydrogeological processes occurring in porous media are typically not amenable to direct observation. As a result, indirect measurements (e.g., contaminant breakthrough at a fixed location) are often used to infer processes occurring at different scales, locations, or times. To overcome this limitation, non-invasive imaging methods are increasingly being used in contaminant hydrogeology research. Four of the most common methods, and the subjects of this review, are optical imaging using UV or visible light, dual-energy gamma radiation, X-ray microtomography, and magnetic resonance imaging (MRI). Non-invasive imaging techniques have provided valuable insights into a variety of complex systems and processes, including porous media characterization, multiphase fluid distribution, fluid flow, solute transport and mixing, colloidal transport and deposition, and reactions. In this paper we review the theory underlying these methods, applications of these methods to contaminant hydrogeology research, and methods' advantages and disadvantages. As expected, there is no perfect method or tool for non-invasive imaging. However, optical methods generally present the least expensive and easiest options for imaging fluid distribution, solute and fluid flow, colloid transport, and reactions in artificial two-dimensional (2D) porous media. Gamma radiation methods present the best opportunity for characterization of fluid distributions in 2D at the Darcy scale. X-ray methods present the highest resolution and flexibility for three-dimensional (3D) natural porous media characterization, and 3D characterization of fluid distributions in natural porous media. And MRI presents the best option for 3D characterization of fluid distribution, fluid flow, colloid transport, and reaction in artificial porous media. Obvious deficiencies ripe for method development are the ability to image transient processes such as fluid flow and colloid transport in natural porous media in three

  1. A General Approach to the Non-Invasive Imaging of Transgenes Using Cis-Linked Herpes Simplex Virus Thymidine Kinase

    Directory of Open Access Journals (Sweden)

    Juri G. Tjuvajev

    1999-10-01

    Full Text Available Non-invasive imaging of gene expression opens new prospects for the study of transgenic animals and the implementation of genetically based therapies in patients. We have sought to establish a general paradigm to enable whole body non-invasive imaging of any transgene. We show that the expression and imaging of HSV1-tk (a marker gene can be used to monitor the expression of the LacZ gene (a second gene under the transcriptional control of a single promoter within a bicistronic unit that includes a type II internal ribosomal entry site. In cells bearing a single copy of the vector, the expression of the two genes is proportional and constant, both in vitro and in vivo. We demonstrate that non-invasive imaging of HSV1-tk gene accurately reflects the topology and activity of the other cis-linked transgene.

  2. Non-invasive imaging of skin cancer with fluorescence lifetime imaging using two photon tomography

    Science.gov (United States)

    Patalay, Rakesh; Talbot, Clifford; Alexandrov, Yuriy; Munro, Ian; Breunig, Hans Georg; König, Karsten; Warren, Sean; Neil, Mark A. A.; French, Paul M. W.; Chu, Anthony; Stamp, Gordon W.; Dunsby, Christopher

    2011-07-01

    Multispectral fluorescence lifetime imaging (FLIM) using two photon microscopy as a non-invasive technique for the diagnosis of skin lesions is described. Skin contains fluorophores including elastin, keratin, collagen, FAD and NADH. This endogenous contrast allows tissue to be imaged without the addition of exogenous agents and allows the in vivo state of cells and tissues to be studied. A modified DermaInspect® multiphoton tomography system was used to excite autofluorescence at 760 nm in vivo and on freshly excised ex vivo tissue. This instrument simultaneously acquires fluorescence lifetime images in four spectral channels between 360-655 nm using time-correlated single photon counting and can also provide hyperspectral images. The multispectral fluorescence lifetime images were spatially segmented and binned to determine lifetimes for each cell by fitting to a double exponential lifetime model. A comparative analysis between the cellular lifetimes from different diagnoses demonstrates significant diagnostic potential.

  3. Non-invasive imaging of epileptic seizures in vivo using photoacoustic tomography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Qizhi; Carney, Paul R; Yuan Zhen; Jiang Huabei [J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611 (United States); Liu Zhao [Department of Pediatrics, Division of Pediatric Neurology, University of Florida, Gainesville, FL 32610 (United States); Chen Huanxin; Roper, Steven N [Department of Neurosurgery, University of Florida, Gainesville, FL 32610-0265 (United States)], E-mail: hjiang@bme.ufl.edu

    2008-04-07

    Non-invasive laser-induced photoacoustic tomography (PAT) is an emerging imaging modality that has the potential to image the dynamic function of the brain due to its unique ability of imaging biological tissues with high optical contrast and ultrasound resolution. Here we report the first application of our finite-element-based PAT for imaging of epileptic seizures in an animal model. In vivo photoacoustic images were obtained in rats with focal seizures induced by microinjection of bicuculline, a GABA{sub A} antagonist, into the neocortex. The seizure focus was accurately localized by PAT as confirmed with gold-standard electroencephalogram (EEG). Compared to the existing neuroimaging modalities, PAT not only has the unprecedented advantage of high spatial and temporal resolution in a single imaging modality, but also is portable and low in cost, making it possible to bring brain imaging to the bedside.

  4. ELECTROCARDIOGRAPHIC ABNORMALITIES AMONG MEXICAN AMERICANS: CORRELATIONS WITH DIABETES, OBESITY, AND THE METABOLIC SYNDROME.

    Science.gov (United States)

    Queen, Saulette R; Smulevitz, Beverly; Rentfro, Anne R; Vatcheva, Kristina P; Kim, Hyunggun; McPherson, David D; Hanis, Craig L; Fisher-Hoch, Susan P; McCormick, Joseph B; Laing, Susan T

    2012-04-01

    Resting ischemic electrocardiographic abnormalities have been associated with cardiovascular mortality. Simple markers of abnormal autonomic tone have also been associated with diabetes, obesity, and the metabolic syndrome in some populations. Data on these electrocardiographic abnormalities and correlations with coronary risk factors are lacking among Mexican Americans wherein these conditions are prevalent. This study aimed to evaluate the prevalent resting electrocardiographic abnormalities among community-dwelling Mexican Americans, and correlate these findings with coronary risk factors, particularly diabetes, obesity, and the metabolic syndrome. Study subjects (n=1280) were drawn from the Cameron County Hispanic Cohort comprised of community-dwelling Mexican Americans living in Brownsville, Texas at the United States-Mexico border. Ischemic electrocardiographic abnormalities were defined as presence of ST/T wave abnormalities suggestive of ischemia, abnormal Q waves, and left bundle branch block. Parameters that reflect autonomic tone, such as heart rate-corrected QT interval and resting heart rate, were also measured. Ischemic electrocardiographic abnormalities were more prevalent among older persons and those with hypertension, diabetes, obesity, and the metabolic syndrome. Subjects in the highest quartiles of QTc interval and resting heart rate were also more likely to be diabetic, hypertensive, obese, or have the metabolic syndrome. Among Mexican Americans, persons with diabetes, obesity, and the metabolic syndrome were more likely to have ischemic electrocardiographic abnormalities, longer QTc intervals, and higher resting heart rates. A resting electrocardiogram can play a complementary role in the comprehensive evaluation of cardiovascular risk in this minority population.

  5. Non-invasive long-term fluorescence live imaging of Tribolium castaneum embryos.

    Science.gov (United States)

    Strobl, Frederic; Stelzer, Ernst H K

    2014-06-01

    Insect development has contributed significantly to our understanding of metazoan development. However, most information has been obtained by analyzing a single species, the fruit fly Drosophila melanogaster. Embryonic development of the red flour beetle Tribolium castaneum differs fundamentally from that of Drosophila in aspects such as short-germ development, embryonic leg development, extensive extra-embryonic membrane formation and non-involuted head development. Although Tribolium has become the second most important insect model organism, previous live imaging attempts have addressed only specific questions and no long-term live imaging data of Tribolium embryogenesis have been available. By combining light sheet-based fluorescence microscopy with a novel mounting method, we achieved complete, continuous and non-invasive fluorescence live imaging of Tribolium embryogenesis at high spatiotemporal resolution. The embryos survived the 2-day or longer imaging process, developed into adults and produced fertile progeny. Our data document all morphogenetic processes from the rearrangement of the uniform blastoderm to the onset of regular muscular movement in the same embryo and in four orientations, contributing significantly to the understanding of Tribolium development. Furthermore, we created a comprehensive chronological table of Tribolium embryogenesis, integrating most previous work and providing a reference for future studies. Based on our observations, we provide evidence that serosa window closure and serosa opening, although deferred by more than 1 day, are linked. All our long-term imaging datasets are available as a resource for the community. Tribolium is only the second insect species, after Drosophila, for which non-invasive long-term fluorescence live imaging has been achieved. © 2014. Published by The Company of Biologists Ltd.

  6. Noninvasive Multimodal Imaging to Predict Recovery of Locomotion after Extended Limb Ischemia.

    Directory of Open Access Journals (Sweden)

    Jason S Radowsky

    Full Text Available Acute limb ischemia is a common cause of morbidity and mortality following trauma both in civilian centers and in combat related injuries. Rapid determination of tissue viability and surgical restoration of blood flow are desirable, but not always possible. We sought to characterize the response to increasing periods of hind limb ischemia in a porcine model such that we could define a period of critical ischemia (the point after which irreversible neuromuscular injury occurs, evaluate non-invasive methods for characterizing that ischemia, and establish a model by which we could predict whether or not the animal's locomotion would return to baselines levels post-operatively. Ischemia was induced by either application of a pneumatic tourniquet or vessel occlusion (performed by clamping the proximal iliac artery and vein at the level of the inguinal ligament. The limb was monitored for the duration of the procedure with both 3-charge coupled device (3CCD and infrared (IR imaging for tissue oxygenation and perfusion, respectively. The experimental arms of this model are effective at inducing histologically evident muscle injury with some evidence of expected secondary organ damage, particularly in animals with longer ischemia times. Noninvasive imaging data shows excellent correlation with post-operative functional outcomes, validating its use as a non-invasive means of viability assessment, and directly monitors post-occlusive reactive hyperemia. A classification model, based on partial-least squares discriminant analysis (PLSDA of imaging variables only, successfully classified animals as "returned to normal locomotion" or "did not return to normal locomotion" with 87.5% sensitivity and 66.7% specificity after cross-validation. PLSDA models generated from non-imaging data were not as accurate (AUC of 0.53 compared the PLSDA model generated from only imaging data (AUC of 0.76. With some modification, this limb ischemia model could also serve as a

  7. Targets and probes for non-invasive imaging of β-cells

    Energy Technology Data Exchange (ETDEWEB)

    Jodal, Andreas; Behe, Martin [Paul Scherrer Institut, Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Villigen (Switzerland); Schibli, Roger [Paul Scherrer Institut, Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Villigen (Switzerland); ETH Zurich, Department of Chemistry and Applied Biosciences, Zurich (Switzerland)

    2017-04-15

    β-cells, located in the islets of the pancreas, are responsible for production and secretion of insulin and play a crucial role in blood sugar regulation. Pathologic β-cells often cause serious medical conditions affecting blood glucose level, which severely impact life quality and are life-threatening if untreated. With 347 million patients, diabetes is one of the most prevalent diseases, and will continue to be one of the largest socioeconomic challenges in the future. The diagnosis still relies mainly on indirect methods like blood sugar measurements. A non-invasive diagnostic imaging modality would allow direct evaluation of β-cell mass and would be a huge step towards personalized medicine. Hyperinsulinism is another serious condition caused by β-cells that excessively secrete insulin, like for instance β-cell hyperplasia and insulinomas. Treatment options with drugs are normally not curative, whereas curative procedures usually consist of the resection of affected regions for which, however, an exact localization of the foci is necessary. In this review, we describe potential tracers under development for targeting β-cells with focus on radiotracers for PET and SPECT imaging, which allow the non-invasive visualization of β-cells. We discuss either the advantages or limitations for the various tracers and modalities. This article concludes with an outlook on future developments and discuss the potential of new imaging probes including dual probes that utilize functionalities for both a radioactive and optical moiety as well as for theranostic applications. (orig.)

  8. Targets and probes for non-invasive imaging of β-cells

    International Nuclear Information System (INIS)

    Jodal, Andreas; Behe, Martin; Schibli, Roger

    2017-01-01

    β-cells, located in the islets of the pancreas, are responsible for production and secretion of insulin and play a crucial role in blood sugar regulation. Pathologic β-cells often cause serious medical conditions affecting blood glucose level, which severely impact life quality and are life-threatening if untreated. With 347 million patients, diabetes is one of the most prevalent diseases, and will continue to be one of the largest socioeconomic challenges in the future. The diagnosis still relies mainly on indirect methods like blood sugar measurements. A non-invasive diagnostic imaging modality would allow direct evaluation of β-cell mass and would be a huge step towards personalized medicine. Hyperinsulinism is another serious condition caused by β-cells that excessively secrete insulin, like for instance β-cell hyperplasia and insulinomas. Treatment options with drugs are normally not curative, whereas curative procedures usually consist of the resection of affected regions for which, however, an exact localization of the foci is necessary. In this review, we describe potential tracers under development for targeting β-cells with focus on radiotracers for PET and SPECT imaging, which allow the non-invasive visualization of β-cells. We discuss either the advantages or limitations for the various tracers and modalities. This article concludes with an outlook on future developments and discuss the potential of new imaging probes including dual probes that utilize functionalities for both a radioactive and optical moiety as well as for theranostic applications. (orig.)

  9. High-resolution ultrasound imaging and noninvasive optoacoustic monitoring of blood variables in peripheral blood vessels

    Science.gov (United States)

    Petrov, Irene Y.; Petrov, Yuriy; Prough, Donald S.; Esenaliev, Rinat O.

    2011-03-01

    Ultrasound imaging is being widely used in clinics to obtain diagnostic information non-invasively and in real time. A high-resolution ultrasound imaging platform, Vevo (VisualSonics, Inc.) provides in vivo, real-time images with exceptional resolution (up to 30 microns) using high-frequency transducers (up to 80 MHz). Recently, we built optoacoustic systems for probing radial artery and peripheral veins that can be used for noninvasive monitoring of total hemoglobin concentration, oxyhemoglobin saturation, and concentration of important endogenous and exogenous chromophores (such as ICG). In this work we used the high-resolution ultrasound imaging system Vevo 770 for visualization of the radial artery and peripheral veins and acquired corresponding optoacoustic signals from them using the optoacoustic systems. Analysis of the optoacoustic data with a specially developed algorithm allowed for measurement of blood oxygenation in the blood vessels as well as for continuous, real-time monitoring of arterial and venous blood oxygenation. Our results indicate that: 1) the optoacoustic technique (unlike pure optical approaches and other noninvasive techniques) is capable of accurate peripheral venous oxygenation measurement; and 2) peripheral venous oxygenation is dependent on skin temperature and local hemodynamics. Moreover, we performed for the first time (to the best of our knowledge) a comparative study of optoacoustic arterial oximetry and a standard pulse oximeter in humans and demonstrated superior performance of the optoacoustic arterial oximeter, in particular at low blood flow.

  10. Non-invasive vascular imaging: assessing tumour vascularity

    International Nuclear Information System (INIS)

    Delorme, S.; Knopp, M.V.

    1998-01-01

    Non-invasive assessment of vascularity is a new diagnostic approach to characterise tumours. Vascular assessment is based on the pathophysiology of tumour angiogenesis and its diagnostic implications for tumour biology, prognosis and therapy response. Two current techniques investigating vascular features in addition to morphology are Doppler ultrasonography and contrast-enhanced MRI. Diagnostic differentiation has been shown to be possible with Doppler, and a high degree of observed vascularity could be linked to an aggressive course of the disease. Dynamic MRI using gadolinium chelates is already used clinically to detect and differentiate tumours. The histological correlation shows that capillary permeability is increased in malignant tumours and is the best criterion for differentiation from benign processes. Permeability and perfusion factors seem to be more diagnostic than overall vessel density. New clinical applications are currently being established for therapy monitoring. Further instrumental developments will bring harmonic imaging in Doppler, and faster imaging techniques, higher spatial resolution and novel pharmacokinetic concepts in MRI. Upcoming contrast agents for both Doppler and MRI will further improve estimation of intratumoural blood volume and vascular permeability. (orig.)

  11. Clinical Electrocardiographic and Echocardiographic Features of ...

    African Journals Online (AJOL)

    Clinical Electrocardiographic and Echocardiographic Features of Atrial Fibrillation in Nigerians: An Analysis of 39 Patients Seen at the Lagos University Teaching Hospital. ... Congestive cardiac failure was present in 74% of the subjects with a mean NYHA class of about III. Embolic phenomenon was observed in 15% of the ...

  12. Patient management after noninvasive cardiac imaging results from SPARC (Study of myocardial perfusion and coronary anatomy imaging roles in coronary artery disease).

    NARCIS (Netherlands)

    Hachamovitch, R.; Nutter, B.; Hlatky, M.A.; Shaw, L.J.; Ridner, M.L.; Dorbala, S.; Beanlands, R.S.; Chow, B.J.; Branscomb, E.; Chareonthaitawee, P.; Weigold, W.G.; Voros, S.; Abbara, S.; Yasuda, T.; Jacobs, J.E.; Lesser, J.; Berman, D.S.; Thomson, L.E.; Raman, S.; Heller, G.V.; Schussheim, A.; Brunken, R.; Williams, K.A.; Farkas, S.; Delbeke, D.; Schoepf, U.J.; Reichek, N.; Rabinowitz, S.; Sigman, S.R.; Patterson, R.; Corn, C.R.; White, R.; Kazerooni, E.; Corbett, J.; Bokhari, S.; Machac, J.; Guarneri, E.; Borges-Neto, S.; Millstine, J.W.; Caldwell, J.; Arrighi, J.; Hoffmann, U.; Budoff, M.; Lima, J.; Johnson, J.R.; Johnson, B.; Gaber, M.; Williams, J.A.; Foster, C.; Hainer, J.; Carli, M.F. Di

    2012-01-01

    OBJECTIVES: This study examined short-term cardiac catheterization rates and medication changes after cardiac imaging. BACKGROUND: Noninvasive cardiac imaging is widely used in coronary artery disease, but its effects on subsequent patient management are unclear. METHODS: We assessed the 90-day

  13. The use of non-invasive fetal electrocardiography in diagnosing second-degree fetal atrioventricular block.

    Science.gov (United States)

    Lakhno, Igor; Behar, Joachim A; Oster, Julien; Shulgin, Vyacheslav; Ostras, Oleksii; Andreotti, Fernando

    2017-01-01

    Complete atrioventricular block in fetuses is known to be mostly associated with autoimmune disease and can be irreversible if no steroids treatment is provided. Conventional methods used in clinical practice for diagnosing fetal arrhythmia are limited since they do not reflect the primary electrophysiological conduction processes that take place in the myocardium. The non-invasive fetal electrocardiogram has the potential to better support fetal arrhythmias diagnosis through the continuous analysis of the beat to beat variation of the fetal heart rate and morphological analysis of the PQRST complex. We present two retrospective case reports on which atrioventricular block diagnosis could have been supported by the non-invasive fetal electrocardiogram. The two cases comprised a 22-year-old pregnant woman with the gestational age of 31 weeks and a 25-year-old pregnant woman with the gestational age of 41 weeks. Both women were admitted to the Department of Maternal and Fetal Medicine at the Kyiv and Kharkiv municipal perinatal clinics. Patients were observed using standard fetal monitoring methods as well as the non-invasive fetal electrocardiogram. The non-invasive fetal electrocardiographic recordings were analyzed retrospectively, where it is possible to identify the presence of the atrioventricular block. This study demonstrates, for the first time, the feasibility of the non-invasive fetal electrocardiogram as a supplementary method to diagnose of the fetal atrioventricular block. Combined with current fetal monitoring techniques, non-invasive fetal electrocardiography could support clinical decisions.

  14. Peering beneath the surface: novel imaging techniques to noninvasively select gametes and embryos for ART.

    Science.gov (United States)

    Jasensky, Joshua; Swain, Jason E

    2013-10-01

    Embryo imaging has long been a critical tool for in vitro fertilization laboratories, aiding in morphological assessment of embryos, which remains the primary tool for embryo selection. With the recent emergence of clinically applicable real-time imaging systems to assess embryo morphokinetics, a renewed interest has emerged regarding noninvasive methods to assess gamete and embryo development as a means of inferring quality. Several studies exist that utilize novel imaging techniques to visualize or quantify intracellular components of gametes and embryos with the intent of correlating localization of organelles or molecular constitution with quality or outcome. However, the safety of these approaches varies due to the potential detrimental impact of light exposure or other variables. Along with complexity of equipment and cost, these drawbacks currently limit clinical application of these novel microscopes and imaging techniques. However, as evidenced by clinical incorporation of some real-time imaging devices as well as use of polarized microscopy, some of these imaging approaches may prove to be useful. This review summarizes the existing literature on novel imaging approaches utilized to examine gametes and embryos. Refinement of some of these imaging systems may permit clinical application and serve as a means to offer new, noninvasive selection tools to improve outcomes for various assisted reproductive technology procedures.

  15. Exertional headache and coronary ischemia despite normal electrocardiographic stress testing.

    Science.gov (United States)

    Cutrer, F Michael; Huerter, Karina

    2006-01-01

    Exertional headaches may under certain conditions reflect coronary ischemia. We report the case of a patient seen in a neurology referral practice whose exertional headaches, even in the face of two normal electrocardiographic stress tests and in the absence of underlying chest pain were the sole symptoms of coronary ischemia as detected by Tc-99m Sestamibi testing SPECT stress testing. Stent placement resulted in complete resolution of headaches. Exertional headache in the absence of chest pain may reflect underlying symptomatic coronary artery disease (CAD) even when conventional electrocardiographic stress testing does not indicate ischemia.

  16. Third degree skin burns caused by a MRI conditional electrocardiographic monitoring system

    Directory of Open Access Journals (Sweden)

    Brix L

    2016-10-01

    Full Text Available Two unusual cases of third degree skin burns are reported using MRI approved electrocardiographic leads. This is very uncommon as it is most often the electrodes which are the source of heat related issues. Both patients were sedated due to pain related issues of their lower spine. The burns were caused by a combination of using a 3 Tesla MRI scanner and the inability to cry out during scanning. We would like to bring forward a message that even when using MRI conditional equipment, clinical staff must be extremely careful in order to secure safe image acquisition using MRI.

  17. Noninvasive imaging systems for gametes and embryo selection in IVF programs: a review.

    Science.gov (United States)

    Omidi, Marjan; Faramarzi, Azita; Agharahimi, Azam; Khalili, Mohammad Ali

    2017-09-01

    Optimizing the efficiency of the in vitro fertilization procedure by improving pregnancy rates and reducing the risks of multiple pregnancies simultaneously are the primary goals of the current assisted reproductive technology program. With the move to single embryo transfers, the need for more cost-effective and noninvasive methods for embryo selection prior to transfer is paramount. These aims require advancement in a more acquire gametes/embryo testing and selection procedures using high-tech devices. Therefore, the aim of the present review is to evaluate the efficacy of noninvasive imaging systems in the current literatures, focusing on the potential clinical application in infertile patients undergoing assisted reproductive technology treatments. In this regards, three advanced imaging systems of motile sperm organelle morphology examination, polarization microscopy and time-lapse monitoring for the best selection of the gametes and preimplantation embryos are introduced in full. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  18. Insights into Parkinson's disease models and neurotoxicity using non-invasive imaging

    International Nuclear Information System (INIS)

    Sanchez-Pernaute, Rosario; Brownell, Anna-Liisa; Jenkins, Bruce G.; Isacson, Ole

    2005-01-01

    Loss of dopamine in the nigrostriatal system causes a severe impairment in motor function in patients with Parkinson's disease and in experimental neurotoxic models of the disease. We have used non-invasive imaging techniques such as positron emission tomography (PET) and functional magnetic resonance imaging (MRI) to investigate in vivo the changes in the dopamine system in neurotoxic models of Parkinson's disease. In addition to classic neurotransmitter studies, in these models, it is also possible to characterize associated and perhaps pathogenic factors, such as the contribution of microglia activation and inflammatory responses to neuronal damage. Functional imaging techniques are instrumental to our understanding and modeling of disease mechanisms, which should in turn lead to development of new therapies for Parkinson's disease and other neurodegenerative disorders

  19. Model-based imaging of cardiac electrical function in human atria

    Science.gov (United States)

    Modre, Robert; Tilg, Bernhard; Fischer, Gerald; Hanser, Friedrich; Messnarz, Bernd; Schocke, Michael F. H.; Kremser, Christian; Hintringer, Florian; Roithinger, Franz

    2003-05-01

    Noninvasive imaging of electrical function in the human atria is attained by the combination of data from electrocardiographic (ECG) mapping and magnetic resonance imaging (MRI). An anatomical computer model of the individual patient is the basis for our computer-aided diagnosis of cardiac arrhythmias. Three patients suffering from Wolff-Parkinson-White syndrome, from paroxymal atrial fibrillation, and from atrial flutter underwent an electrophysiological study. After successful treatment of the cardiac arrhythmia with invasive catheter technique, pacing protocols with stimuli at several anatomical sites (coronary sinus, left and right pulmonary vein, posterior site of the right atrium, right atrial appendage) were performed. Reconstructed activation time (AT) maps were validated with catheter-based electroanatomical data, with invasively determined pacing sites, and with pacing at anatomical markers. The individual complex anatomical model of the atria of each patient in combination with a high-quality mesh optimization enables accurate AT imaging, resulting in a localization error for the estimated pacing sites within 1 cm. Our findings may have implications for imaging of atrial activity in patients with focal arrhythmias.

  20. Non-invasive detection of murals with pulsed terahertz reflected imaging system

    Science.gov (United States)

    Yuan, Minjie; Sun, Wenfeng; Wang, Xinke; Ye, Jiasheng; Wang, Sen; Zhang, Qunxi; Zhang, Yan

    2015-11-01

    Pulsed terahertz reflected imaging technology has been expected to have great potential for the non-invasive analysis of artworks. In this paper, three types of defects hidden in the plaster used to simulate the cases of defects in the murals, have been investigated by a pulsed terahertz reflected imaging system. These preset defects include a circular groove, a cross-shaped slit and a piece of "Y-type" metal plate built in the plaster. With the terahertz reflective tomography, information about defects has been determined involving the thickness from the surface of sample to the built-in defect, the profile and distribution of the defect. Additionally, three-dimensional analyses have been performed in order to reveal the internal structure of defects. Terahertz reflective imaging can be applied to the defect investigation of the murals.

  1. Comparison of chest pain, electrocardiographic changes and thallium-201 scintigraphy during varying exercise intensities in men with stable angina pectoris

    International Nuclear Information System (INIS)

    Heller, G.V.; Ahmed, I.; Tilkemeier, P.L.; Barbour, M.M.; Garber, C.E.

    1991-01-01

    This study was performed to evaluate the presence of angina pectoris, electrocardiographic changes and reversible thallium-201 defects resulting from 2 different levels of exercise in 19 patients with known coronary artery disease and evidence of exercise-induced ischemia. The exercise protocols consisted of a symptom-limited incremental exercise test (Bruce protocol) followed within 3 to 14 days by a submaximal, steady-state exercise test performed at 70% of the maximal heart rate achieved during the Bruce protocol. The presence and time of onset of angina and electrocardiographic changes (greater than or equal to 0.1 mV ST-segment depression) as well as oxygen uptake, exercise duration and pressure-rate product were recorded. Thallium-201 (2.5 to 3.0 mCi) was injected during the last minute of exercise during both protocols, and the images were analyzed using both computer-assisted quantitation and visual interpretations. Incremental exercise resulted in anginal symptoms in 84% of patients, and electrocardiographic changes and reversible thallium-201 defects in all patients. In contrast, submaximal exercise produced anginal symptoms in only 26% (p less than 0.01) and electrocardiographic changes in only 47% (p less than 0.05), but resulted in thallium-201 defects in 89% of patients (p = not significant). The locations of the thallium-201 defects, when present, were not different between the 2 exercise protocols. These findings confirm the sequence of the ischemic cascade using 2 levels of exercise and demonstrate that the cascade theory is applicable during varying ischemic intensities in the same patient

  2. Cardiovascular dysfunction in obesity and new diagnostic imaging techniques: the role of noninvasive image methods

    Directory of Open Access Journals (Sweden)

    Barbosa JA

    2011-05-01

    Full Text Available José Augusto A Barbosa¹, Alexandre B Rodrigues¹, Cleonice Carvalho C Mota¹, Márcia M Barbosa², Ana C Simões e Silva¹¹Department of Pediatrics, Faculty of Medicine, Federal University of Minas Gerais (UFMG, Belo Horizonte, Minas Gerais, Brazil; ²Ecocenter, Socor Hospital, Belo Horizonte, Minas Gerais, BrazilAbstract: Obesity is a major public health problem affecting adults and children in both developed and developing countries. This condition often leads to metabolic syndrome, which increases the risk of cardiovascular disease. A large number of studies have been carried out to understand the pathogenesis of cardiovascular dysfunction in obese patients. Endothelial dysfunction plays a key role in the progression of atherosclerosis and the development of coronary artery disease, hypertension and congestive heart failure. Noninvasive methods in the field of cardiovascular imaging, such as measuring intima-media thickness, flow-mediated dilatation, tissue Doppler, and strain, and strain rate, constitute new tools for the early detection of cardiac and vascular dysfunction. These techniques will certainly enable a better evaluation of initial cardiovascular injury and allow the correct, timely management of obese patients. The present review summarizes the main aspects of cardiovascular dysfunction in obesity and discusses the application of recent noninvasive imaging methods for the early detection of cardiovascular alterations.Keywords: cardiovascular risk, endothelium dysfunction, obesity, strain and strain rate, tissue Doppler

  3. Non-invasive imaging of retinal blood flow in myeloproliferative neoplasms

    DEFF Research Database (Denmark)

    Willerslev, Anne; Hansen, Mathias M; Klefter, Oliver Niels

    2017-01-01

    PURPOSE: To study the circulation in the retinal vessels in patients with blood dyscrasia due to myeloproliferative neoplasms using non-invasive retinal imaging. METHODS: Prospective consecutive case series of seven treatment-naïve patients with chronic myeloid leukaemia (n = 2), polycythemia vera...... present at baseline in patients with chronic myeloid leukaemia and were replaced by normal patterns at follow-up. Retinopathy, in the form of cotton-wool spots and retinal haemorrhages, was found at presentation in the two patients with chronic myeloid leukaemia and in one patient with polycythemia vera...

  4. Theranostic Iron Oxide/Gold Ion Nanoprobes for MR Imaging and Noninvasive RF Hyperthermia.

    Science.gov (United States)

    Fazal, Sajid; Paul-Prasanth, Bindhu; Nair, Shantikumar V; Menon, Deepthy

    2017-08-30

    This work focuses on the development of a nanoparticulate system that can be used for magnetic resonance (MR) imaging and E-field noninvasive radiofrequency (RF) hyperthermia. For this purpose, an amine-functional gold ion complex (GIC), [Au(III)(diethylenetriamine)Cl]Cl 2 , which generates heat upon RF exposure, was conjugated to carboxyl-functional poly(acrylic acid)-capped iron-oxide nanoparticles (IO-PAA NPs) to form IO-GIC NPs of size ∼100 nm. The multimodal superparamagnetic IO-GIC NPs produced T2-contrast on MR imaging and unlike IO-PAA NPs generated heat on RF exposure. The RF heating response of IO-GIC NPs was found to be dependent on the RF power, exposure period, and particle concentration. IO-GIC NPs at a concentration of 2.5 mg/mL showed a high heating response (δT) of ∼40 °C when exposed to 100 W RF power for 1 min. In vitro cytotoxicity measurements on NIH-3T3 fibroblast cells and 4T1 cancer cells showed that IO-GIC NPs are cytocompatible at high NP concentrations for up to 72 h. Upon in vitro RF exposure (100 W, 1 min), a high thermal response leads to cell death of 4T1 cancer cells incubated with IO-GIC NPs (1 mg/mL). Hematoxylin and eosin imaging of rat liver tissues injected with 100 μL of 2.5 mg/mL IO-GIC NPs and exposed to low RF power of 20 W for 10 min showed significant loss of tissue morphology at the site of injection, as against RF-exposed or nanoparticle-injected controls. In vivo MR imaging and noninvasive RF exposure of 4T1-tumor-bearing mice after IO-GIC NP administration showed T2 contrast enhancement and a localized generation of high temperatures in tumors, leading to tumor tissue damage. Furthermore, the administration of IO-GIC NPs followed by RF exposure showed no adverse acute toxicity effects in vivo. Thus, IO-GIC NPs show good promise as a theranostic agent for magnetic resonance imaging and noninvasive RF hyperthermia for cancer.

  5. Noninvasive assessment of coronary collaterals in man by PET perfusion imaging

    International Nuclear Information System (INIS)

    Demer, L.L.; Gould, K.L.; Goldstein, R.A.; Kirkeeide, R.L.

    1990-01-01

    At present, coronary collateralization cannot be identified or assessed noninvasively in patients. In animal studies, coronary collaterals are associated with coronary steal, defined as a regional fall in perfusion during coronary arteriolar vasodilation. To determine the effect of coronary arteriolar vasodilation on collateral bed perfusion in man, myocardial perfusion imaging was performed before and after pharmacologic coronary vasodilation in patients with coronary artery disease (CAD). Regional myocardial activity of 82 Rb or 13 N ammonia was measured by positron emission tomography (PET) at rest and with intravenous dipyridamole/handgrip stress in 28 patients with angiographic collaterals and in 25 control patients with similar CAD severity by quantitative arteriography. Regional myocardial activity decreased after dipyridamole, indicating coronary steal, in 25 of 28 patients with angiographic collaterals and in only 4 of 25 control patients without angiographic collaterals. These findings suggest that developed collaterals are associated with myocardial steal in patients with CAD, allowing potential use of PET for non-invasive identification of coronary collateralization

  6. Continuous non-invasive blood glucose monitoring by spectral image differencing method

    Science.gov (United States)

    Huang, Hao; Liao, Ningfang; Cheng, Haobo; Liang, Jing

    2018-01-01

    Currently, the use of implantable enzyme electrode sensor is the main method for continuous blood glucose monitoring. But the effect of electrochemical reactions and the significant drift caused by bioelectricity in body will reduce the accuracy of the glucose measurements. So the enzyme-based glucose sensors need to be calibrated several times each day by the finger-prick blood corrections. This increases the patient's pain. In this paper, we proposed a method for continuous Non-invasive blood glucose monitoring by spectral image differencing method in the near infrared band. The method uses a high-precision CCD detector to switch the filter in a very short period of time, obtains the spectral images. And then by using the morphological method to obtain the spectral image differences, the dynamic change of blood sugar is reflected in the image difference data. Through the experiment proved that this method can be used to monitor blood glucose dynamically to a certain extent.

  7. Fibered Confocal Fluorescence Microscopy for the Noninvasive Imaging of Langerhans Cells in Macaques.

    Science.gov (United States)

    Todorova, Biliana; Salabert, Nina; Tricot, Sabine; Boisgard, Raphaël; Rathaux, Mélanie; Le Grand, Roger; Chapon, Catherine

    2017-01-01

    We developed a new approach to visualize skin Langerhans cells by in vivo fluorescence imaging in nonhuman primates. Macaques were intradermally injected with a monoclonal, fluorescently labeled antibody against HLA-DR molecule and were imaged for up to 5 days by fibered confocal microscopy (FCFM). The network of skin Langerhans cells was visualized by in vivo fibered confocal fluorescence microscopy. Quantification of Langerhans cells revealed no changes to cell density with time. Ex vivo experiments confirmed that injected fluorescent HLA-DR antibody specifically targeted Langerhans cells in the epidermis. This study demonstrates the feasibility of single-cell, in vivo imaging as a noninvasive technique to track Langerhans cells in nontransgenic animals.

  8. Chronic pelvic pain: how does noninvasive imaging compare with diagnostic laparoscopy?

    Science.gov (United States)

    Tirlapur, Seema A; Daniels, Jane P; Khan, Khalid S

    2015-12-01

    Chronic pelvic pain (CPP) has an annual prevalence of 38/1000 in the UK, with coexisting pathologies often present. Diagnostic laparoscopy has long been the gold standard diagnostic test, but with up to 40% showing no abnormality, we explore the value of noninvasive imaging, such as pelvic ultrasound and MRI. A literature review from inception until January 2015 of the following databases: PubMed, MEDLINE, Cumulative Index to Nursing and Allied Health Literature, Excerpta Medica database, and System for Information on Grey Literature in Europe were performed to identify published studies assessing the usefulness of ultrasound, MRI, and laparoscopy in the diagnosis of CPP. Three studies (194 women) addressed their comparative performance in patients with endometriosis, showing the sensitivity of ultrasound ranged between 58 and 88.5%; MRI was 56-91.5% and in the one study using histology as its reference standard, the sensitivity of laparoscopy was 85.7%. Noninvasive imaging has the additional benefit of being well tolerated, safer, and cheaper than surgery. CPP, by nature of its multifactorial causation, can be difficult to manage and often requires a multidisciplinary team. Ultrasound and MRI may provide information about the presence or lack of abnormality, which would allow general practitioners or office gynaecologists to initiate treatment and think about surgery as a second-line investigative tool.

  9. Non-invasive monitoring of Streptococcus pyogenes vaccine efficacy using biophotonic imaging.

    Directory of Open Access Journals (Sweden)

    Faraz M Alam

    Full Text Available Streptococcus pyogenes infection of the nasopharynx represents a key step in the pathogenic cycle of this organism and a major focus for vaccine development, requiring robust models to facilitate the screening of potentially protective antigens. One antigen that may be an important target for vaccination is the chemokine protease, SpyCEP, which is cell surface-associated and plays a role in pathogenesis. Biophotonic imaging (BPI can non-invasively characterize the spatial location and abundance of bioluminescent bacteria in vivo. We have developed a bioluminescent derivative of a pharyngeal S. pyogenes strain by transformation of an emm75 clinical isolate with the luxABCDE operon. Evaluation of isogenic recombinant strains in vitro and in vivo confirmed that bioluminescence conferred a growth deficit that manifests as a fitness cost during infection. Notwithstanding this, bioluminescence expression permitted non-invasive longitudinal quantitation of S. pyogenes within the murine nasopharynx albeit with a detection limit corresponding to approximately 10(5 bacterial colony forming units (CFU in this region. Vaccination of mice with heat killed streptococci, or with SpyCEP led to a specific IgG response in the serum. BPI demonstrated that both vaccine candidates reduced S. pyogenes bioluminescence emission over the course of nasopharyngeal infection. The work suggests the potential for BPI to be used in the non-invasive longitudinal evaluation of potential S. pyogenes vaccines.

  10. An embedded system for image segmentation and multimodal registration in noninvasive skin cancer screening.

    Science.gov (United States)

    Diaz, Silvana; Soto, Javier E; Inostroza, Fabian; Godoy, Sebastian E; Figueroa, Miguel

    2017-07-01

    We present a heterogeneous architecture for image registration and multimodal segmentation on an embedded system for noninvasive skin cancer screening. The architecture combines Otsu thresholding and the random walker algorithm to perform image segmentation, and features a hardware implementation of the Harris corner detection algorithm to perform region-of-interest detection and image registration. Running on a Xilinx XC7Z020 reconfigurable system-on-a-chip, our prototype computes the initial segmentation of a 400×400-pixel region of interest in the visible spectrum in 12.1 seconds, and registers infrared images against this region at 540 frames per second, while consuming 1.9W.

  11. Non-invasive imaging of zebrafish with spinal deformities using optical coherence tomography: a preliminary study

    Science.gov (United States)

    Bernstein, Liane; Beaudette, Kathy; Patten, Kessen; Beaulieu-Ouellet, Émilie; Strupler, Mathias; Moldovan, Florina; Boudoux, Caroline

    2013-03-01

    A zebrafish model has recently been introduced to study various genetic mutations that could lead to spinal deformities such as scoliosis. However, current imaging techniques make it difficult to perform longitudinal studies of this condition in zebrafish, especially in the early stages of development. The goal of this project is to determine whether optical coherence tomography (OCT) is a viable non-invasive method to image zebrafish exhibiting spinal deformities. Images of both live and fixed malformed zebrafish (5 to 21 days postfertilization) as well as wild-type fish (5 to 29 days postfertilization) were acquired non-invasively using a commercial SD-OCT system, with a laser source centered at 930nm (λ=100nm), permitting axial and lateral resolutions of 7 and 8μm respectively. Using two-dimensional images and three-dimensional reconstructions, it was possible to identify the malformed notochord as well as deformities in other major organs at different stages of formation. Visualization of the notochord was facilitated with the development of a segmentation algorithm. OCT images were compared to HE histological sections and images obtained by calcein staining. Because of the possibility of performing longitudinal studies on a same fish and reducing image processing time as compared with staining techniques and histology, the use of OCT could facilitate phenotypic characterization in studying genetic factors leading to spinal deformities in zebrafish and could eventually contribute to the identification of the genetic causes of spinal deformities such as scoliosis.

  12. Auscultatory and electrocardiographic characteristics of Crioulo horses

    Directory of Open Access Journals (Sweden)

    Jackson Schade

    2014-03-01

    Full Text Available In order to determine auscultatory and electrocardiographic characteristics of Crioulo horses, one hundred animals ranging between one and twenty-six years of age (21 stallions, nine geldings, 27 pregnant mares e 43 not pregnant mares were evaluated. The cardiac auscultation was performed during the clinical examination of the cardiovascular system, evaluating frequency, rate, normal and abnormal heart sounds (heart murmurs. The electrocardiographic examination followed the bipolar base-apex derivative system with animals at rest, by using an ECG-PC TEB equipment. The cardiac frequency, heart rate, morphology, duration, wave and complex amplitudes and interval durations were determined. The results were submitted to ANOVA and Tukey tests with an error probability of 5%. The cardiac auscultation revealed presence of functional systolic and diastolic murmur (10.00% and systolic murmur compatible with tricuspid regurgitation besides normal heart sounds S1 (100.0%, S2 (100.0%, S3 (19.0% and S4 (34.0%. The cardiac frequency obtained the average of 43.64 bpm, observing significative differences in relation to sexual and age factors and training level. The sinus rhythm was the most frequent (57.00%, followed by sinus tachycardia (38.00% and sinus arrhythmia (5.00%, being observed rhythm disturbances in 16% of tracings. The P and T waves were observed more frequently in their forms P bifida positive (95.00% and biphasic T (91.00%, being variable at tracing. There were also observed Q waves in 12.00% of the tracings. Thus, it was concluded that the auscultatory characteristics of Crioulo horses are according to the described in the literature for the species and the sexual factor, category, age factor and training level can influence some electrocardiographic parameters.

  13. Noninvasive mapping of water diffusional exchange in the human brain using filter-exchange imaging.

    Science.gov (United States)

    Nilsson, Markus; Lätt, Jimmy; van Westen, Danielle; Brockstedt, Sara; Lasič, Samo; Ståhlberg, Freddy; Topgaard, Daniel

    2013-06-01

    We present the first in vivo application of the filter-exchange imaging protocol for diffusion MRI. The protocol allows noninvasive mapping of the rate of water exchange between microenvironments with different self-diffusivities, such as the intracellular and extracellular spaces in tissue. Since diffusional water exchange across the cell membrane is a fundamental process in human physiology and pathophysiology, clinically feasible and noninvasive imaging of the water exchange rate would offer new means to diagnose disease and monitor treatment response in conditions such as cancer and edema. The in vivo use of filter-exchange imaging was demonstrated by studying the brain of five healthy volunteers and one intracranial tumor (meningioma). Apparent exchange rates in white matter range from 0.8±0.08 s(-1) in the internal capsule, to 1.6±0.11 s(-1) for frontal white matter, indicating that low values are associated with high myelination. Solid tumor displayed values of up to 2.9±0.8 s(-1). In white matter, the apparent exchange rate values suggest intra-axonal exchange times in the order of seconds, confirming the slow exchange assumption in the analysis of diffusion MRI data. We propose that filter-exchange imaging could be used clinically to map the water exchange rate in pathologies. Filter-exchange imaging may also be valuable for evaluating novel therapies targeting the function of aquaporins. Copyright © 2012 Wiley Periodicals, Inc.

  14. High-resolution harmonics ultrasound imaging for non-invasive characterization of wound healing in a pre-clinical swine model.

    Directory of Open Access Journals (Sweden)

    Surya C Gnyawali

    Full Text Available This work represents the first study employing non-invasive high-resolution harmonic ultrasound imaging to longitudinally characterize skin wound healing. Burn wounds (day 0-42, on the dorsum of a domestic Yorkshire white pig were studied non-invasively using tandem digital planimetry, laser speckle imaging and dual mode (B and Doppler ultrasound imaging. Wound depth, as measured by B-mode imaging, progressively increased until day 21 and decreased thereafter. Initially, blood flow at the wound edge increased up to day 14 and subsequently regressed to baseline levels by day 21, when the wound was more than 90% closed. Coinciding with regression of blood flow at the wound edge, there was an increase in blood flow in the wound bed. This was observed to regress by day 42. Such changes in wound angiogenesis were corroborated histologically. Gated Doppler imaging quantitated the pulse pressure of the primary feeder artery supplying the wound site. This pulse pressure markedly increased with a bimodal pattern following wounding connecting it to the induction of wound angiogenesis. Finally, ultrasound elastography measured tissue stiffness and visualized growth of new tissue over time. These studies have elegantly captured the physiological sequence of events during the process of wound healing, much of which is anticipated based on certain dynamics in play, to provide the framework for future studies on molecular mechanisms driving these processes. We conclude that the tandem use of non-invasive imaging technologies has the power to provide unprecedented insight into the dynamics of the healing skin tissue.

  15. Noninvasive cardiac activation imaging of ventricular arrhythmias during drug-induced QT prolongation in the rabbit heart.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; Zhou, Zhaoye; He, Bin

    2013-10-01

    Imaging myocardial activation from noninvasive body surface potentials promises to aid in both cardiovascular research and clinical medicine. To investigate the ability of a noninvasive 3-dimensional cardiac electrical imaging technique for characterizing the activation patterns of dynamically changing ventricular arrhythmias during drug-induced QT prolongation in rabbits. Simultaneous body surface potential mapping and 3-dimensional intracardiac mapping were performed in a closed-chest condition in 8 rabbits. Data analysis was performed on premature ventricular complexes, couplets, and torsades de pointes (TdP) induced during intravenous administration of clofilium and phenylephrine with combinations of various infusion rates. The drug infusion led to a significant increase in the QT interval (from 175 ± 7 to 274 ± 31 ms) and rate-corrected QT interval (from 183 ± 5 to 262 ± 21 ms) during the first dose cycle. All the ectopic beats initiated by a focal activation pattern. The initial beat of TdPs arose at the focal site, whereas the subsequent beats were due to focal activity from different sites or 2 competing focal sites. The imaged results captured the dynamic shift of activation patterns and were in good correlation with the simultaneous measurements, with a correlation coefficient of 0.65 ± 0.02 averaged over 111 ectopic beats. Sites of initial activation were localized to be ~5 mm from the directly measured initiation sites. The 3-dimensional cardiac electrical imaging technique could localize the origin of activation and image activation sequence of TdP during QT prolongation induced by clofilium and phenylephrine in rabbits. It offers the potential to noninvasively investigate the proarrhythmic effects of drug infusion and assess the mechanisms of arrhythmias on a beat-to-beat basis. © 2013 Heart Rhythm Society. All rights reserved.

  16. Implications of normal exercise electrocardiographic results in patients with angiographically documented coronary artery disease. Correlation with left ventricular function and myocardial perfusion

    International Nuclear Information System (INIS)

    Hakki, A.H.; DePace, N.L.; Colby, J.; Iskandrian, A.S.

    1983-01-01

    The purpose of this study was to examine the incidence and implications of false-negative exercise electrocardiographic results among 216 consecutive patients with angiographically documented coronary artery disease (50 percent diameter narrowing or greater of one or more vessels). Exercise electrocardiography gave negative (false-negative) results in 23 patients and positive (true-positive) results in 102 patients, and were nondiagnostic in the rest. Exercise thallium-201 imaging was performed in 88 patients. The extent of coronary artery disease was quantitated by a scoring system that takes into consideration the degree and site of narrowing in the major vessels and their branches. The exercise heart rate was higher in patients with false-negative than in patients with true-positive exercise electrocardiographic results (161 +/- 18 versus 133 +/- 24 beats per minute, mean +/- SD; p less than 0.0001). Q-wave infarction was present in two patients (9 percent) with false-negative and 20 patients (20 percent) with true-positive exercise electrocardiographic results; left ventricular asynergy at rest was observed in 13 patients (57 percent) with false-negative and in 74 patients (74 percent) with true-positive results. Patients with false-negative results had less extensive coronary disease than did patients with true-positive results (score 5.8 +/- 3.6 versus 9.2 +/- 5.0; p . 0.0025). Angina during exercise was less frequent in patients with false-negative results (p less than 0.01). Abnormal exercise thallium-201 images were seen in 15 of 20 patients (75 percent) with false-negative results and in 56 of 68 patients (82 percent) with true-positive results

  17. Assays for noninvasive imaging of reporter gene expression

    International Nuclear Information System (INIS)

    Gambhir, S.S.; Barrio, J.R.; Herschman, H.R.; Phelps, M.E.

    1999-01-01

    Repeated, noninvasive imaging of reporter gene expression is emerging as a valuable tool for monitoring the expression of genes in animals and humans. Monitoring of organ/cell transplantation in living animals and humans, and the assessment of environmental, behavioral, and pharmacologic modulation of gene expression in transgenic animals should soon be possible. The earliest clinical application is likely to be monitoring human gene therapy in tumors transduced with the herpes simplex virus type 1 thymidine kinase (HSV1-tk) suicide gene. Several candidate assays for imaging reporter gene expression have been studied, utilizing cytosine deaminase (CD), HSV1-tk, and dopamine 2 receptor (D2R) as reporter genes. For the HSV1-tk reporter gene, both uracil nucleoside derivatives (e.g., 5-iodo-2'-fluoro-2'-deoxy-1-β-D-arabinofuranosyl-5-iodouracil [FIAU] labeled with 124 I, 131 I ) and acycloguanosine derivatives {e.g., 8-[ 18 F]fluoro-9-[[2-hydroxy-1-(hydroxymethyl)ethoxy]methyl]guanine (8-[ 18 F]-fluoroganciclovir) ([ 18 F]FGCV), 9-[(3-[ 18 F]fluoro-1-hydroxy-2-propoxy)methyl]guanine ([ 18 F]FHPG)} have been investigated as reporter probes. For the D2R reporter gene, a derivative of spiperone {3-(2'-[ 18 F]-Fluoroethyl)spiperone ([ 18 F]FESP)} has been used with positron emission tomography (PET) imaging. In this review, the principles and specific assays for imaging reporter gene expression are presented and discussed. Specific examples utilizing adenoviral-mediated delivery of a reporter gene as well as tumors expressing reporter genes are discussed

  18. Validity of bioluminescence measurements for noninvasive in vivo imaging of tumor load in small animals

    NARCIS (Netherlands)

    Klerk, Clara P. W.; Overmeer, Renée M.; Niers, Tatjana M. H.; Versteeg, Henri H.; Richel, Dick J.; Buckle, Tessa; van Noorden, Cornelis J. F.; van Tellingen, Olaf

    2007-01-01

    A relatively new strategy to longitudinally monitor tumor load in intact animals and the effects of therapy is noninvasive bioluminescence imaging (BLI). The validity of BLI for quantitative assessment of tumor load in small animals is critically evaluated in the present review. Cancer cells are

  19. A Noninvasive Imaging Approach to Understanding Speech Changes following Deep Brain Stimulation in Parkinson's Disease

    Science.gov (United States)

    Narayana, Shalini; Jacks, Adam; Robin, Donald A.; Poizner, Howard; Zhang, Wei; Franklin, Crystal; Liotti, Mario; Vogel, Deanie; Fox, Peter T.

    2009-01-01

    Purpose: To explore the use of noninvasive functional imaging and "virtual" lesion techniques to study the neural mechanisms underlying motor speech disorders in Parkinson's disease. Here, we report the use of positron emission tomography (PET) and transcranial magnetic stimulation (TMS) to explain exacerbated speech impairment following…

  20. Using Non-Invasive Multi-Spectral Imaging to Quantitatively Assess Tissue Vasculature

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, A; Chernomordik, V; Riley, J; Hassan, M; Amyot, F; Dasgeb, B; Demos, S G; Pursley, R; Little, R; Yarchoan, R; Tao, Y; Gandjbakhche, A H

    2007-10-04

    This research describes a non-invasive, non-contact method used to quantitatively analyze the functional characteristics of tissue. Multi-spectral images collected at several near-infrared wavelengths are input into a mathematical optical skin model that considers the contributions from different analytes in the epidermis and dermis skin layers. Through a reconstruction algorithm, we can quantify the percent of blood in a given area of tissue and the fraction of that blood that is oxygenated. Imaging normal tissue confirms previously reported values for the percent of blood in tissue and the percent of blood that is oxygenated in tissue and surrounding vasculature, for the normal state and when ischemia is induced. This methodology has been applied to assess vascular Kaposi's sarcoma lesions and the surrounding tissue before and during experimental therapies. The multi-spectral imaging technique has been combined with laser Doppler imaging to gain additional information. Results indicate that these techniques are able to provide quantitative and functional information about tissue changes during experimental drug therapy and investigate progression of disease before changes are visibly apparent, suggesting a potential for them to be used as complementary imaging techniques to clinical assessment.

  1. Anaphylaxis Imaging: Non-Invasive Measurement of Surface Body Temperature and Physical Activity in Small Animals.

    Directory of Open Access Journals (Sweden)

    Krisztina Manzano-Szalai

    Full Text Available In highly sensitized patients, the encounter with a specific allergen from food, insect stings or medications may rapidly induce systemic anaphylaxis with potentially lethal symptoms. Countless animal models of anaphylaxis, most often in BALB/c mice, were established to understand the pathophysiology and to prove the safety of different treatments. The most common symptoms during anaphylactic shock are drop of body temperature and reduced physical activity. To refine, improve and objectify the currently applied manual monitoring methods, we developed an imaging method for the automated, non-invasive measurement of the whole-body surface temperature and, at the same time, of the horizontal and vertical movement activity of small animals. We tested the anaphylaxis imaging in three in vivo allergy mouse models for i milk allergy, ii peanut allergy and iii egg allergy. These proof-of-principle experiments suggest that the imaging technology represents a reliable non-invasive method for the objective monitoring of small animals during anaphylaxis over time. We propose that the method will be useful for monitoring diseases associated with both, changes in body temperature and in physical behaviour.

  2. Electrocardiographic Preexcitation and Risk of Cardiovascular Morbidity and Mortality

    DEFF Research Database (Denmark)

    Skov, Morten W.; Rasmussen, Peter V.; Ghouse, Jonas

    2017-01-01

    Background - The majority of available data on the clinical course of patients with ventricular preexcitation in the ECG originates from tertiary centers. We aimed to investigate long-term outcomes in individuals from a primary care population with electrocardiographic preexcitation. Methods and ...

  3. Diagnostic electrocardiographic dyad criteria of emphysema in left ventricular hypertrophy.

    Science.gov (United States)

    Lanjewar, Swapnil S; Chhabra, Lovely; Chaubey, Vinod K; Joshi, Saurabh; Kulkarni, Ganesh; Kothagundla, Chandrasekhar; Kaul, Sudesh; Spodick, David H

    2013-01-01

    The electrocardiographic diagnostic dyad of emphysema, namely a combination of the frontal vertical P-vector and a narrow QRS duration, can serve as a quasidiagnostic marker for emphysema, with specificity close to 100%. We postulated that the presence of left ventricular hypertrophy in emphysema may affect the sensitivity of this electrocardiographic criterion given that left ventricular hypertrophy generates prominent left ventricular forces and may increase the QRS duration. We reviewed the electrocardiograms and echocardiograms for 73 patients with emphysema. The patients were divided into two groups based on the presence or absence of echocardiographic evidence of left ventricular hypertrophy. The P-vector, QRS duration, and forced expiratory volume in one second (FEV1) were computed and compared between the two subgroups. There was no statistically significant difference in qualitative lung function (FEV1) between the subgroups. There was no statistically significant difference in mean P-vector between the subgroups. The mean QRS duration was significantly longer in patients with left ventricular hypertrophy as compared with those without left ventricular hypertrophy. The presence of left ventricular hypertrophy may not affect the sensitivity of the P-vector verticalization when used as a lone criterion for diagnosing emphysema. However, the presence of left ventricular hypertrophy may significantly reduce the sensitivity of the electrocardiographic diagnostic dyad in emphysema, as it causes a widening of the QRS duration.

  4. An overview of contemporary nuclear cardiology.

    Science.gov (United States)

    Lewin, Howard C; Sciammarella, Maria G; Watters, Thomas A; Alexander, Herbert G

    2004-01-01

    Myocardial perfusion single photon emission computed tomography (SPECT) is a widely utilized noninvasive imaging modality for the diagnosis, prognosis, and risk stratification of coronary artery disease. It is clearly superior to the traditional planar technique in terms of imaging contrast and consequent diagnostic and prognostic yield. The strength of SPECT images is largely derived from the three-dimensional, volumetric nature of its image. Thus, this modality permits three-dimensional assessment and quantitation of the perfused myocardium and functional assessment through electrocardiographic gating of the perfusion images.

  5. Utility of spatial frequency domain imaging (SFDI) and laser speckle imaging (LSI) to non-invasively diagnose burn depth in a porcine model☆

    Science.gov (United States)

    Burmeister, David M.; Ponticorvo, Adrien; Yang, Bruce; Becerra, Sandra C.; Choi, Bernard; Durkin, Anthony J.; Christy, Robert J.

    2015-01-01

    Surgical intervention of second degree burns is often delayed because of the difficulty in visual diagnosis, which increases the risk of scarring and infection. Non-invasive metrics have shown promise in accurately assessing burn depth. Here, we examine the use of spatial frequency domain imaging (SFDI) and laser speckle imaging (LSI) for predicting burn depth. Contact burn wounds of increasing severity were created on the dorsum of a Yorkshire pig, and wounds were imaged with SFDI/LSI starting immediately after-burn and then daily for the next 4 days. In addition, on each day the burn wounds were biopsied for histological analysis of burn depth, defined by collagen coagulation, apoptosis, and adnexal/vascular necrosis. Histological results show that collagen coagulation progressed from day 0 to day 1, and then stabilized. Results of burn wound imaging using non-invasive techniques were able to produce metrics that correlate to different predictors of burn depth. Collagen coagulation and apoptosis correlated with SFDI scattering coefficient parameter ( μs′) and adnexal/vascular necrosis on the day of burn correlated with blood flow determined by LSI. Therefore, incorporation of SFDI scattering coefficient and blood flow determined by LSI may provide an algorithm for accurate assessment of the severity of burn wounds in real time. PMID:26138371

  6. Electrocardiographic features of patients with earthquake related posttraumatic stress disorder

    OpenAIRE

    İlhan, Erkan; Kaplan, Abdullah; Güvenç, Tolga Sinan; Biteker, Murat; Karabulut, Evindar; Işıklı, Serhan

    2013-01-01

    AIM: To analyze electrocardiographic features of patients diagnosed with posttraumatic stress disorder (PTSD) after the Van-Erciş earthquake, with a shock measuring 7.2 on the Richter scale that took place in Turkey in October 2011.

  7. Female alcoholics: electrocardiographic changes and associated metabolic and electrolytic disorders

    Directory of Open Access Journals (Sweden)

    Borini Paulo

    2003-01-01

    Full Text Available OBJECTIVE: To identify the electrocardiographic changes and their associations with metabolic and electrolytic changes in female alcoholics. METHODS: The study comprised 44 female alcoholics with no apparent physical disorder. They underwent the following examinations: conventional electrocardiography; serologic tests for syphilis, Chagas' disease, and hepatitis B and C viruses; urinary pregnancy testing; hematimetric analysis; biochemical measurements of albumin, fibrinogen, fasting and postprandial glycemias, lipids, hepatic enzymes, and markers for tissue necrosis and inflammation. RESULTS: Some type of electrocardiographic change was identified in 33 (75% patients. In 17 (38.6% patients, more than one of the following changes were present: prolonged QTc interval in 24 (54.5%, change in ventricular repolarization in 11(25%, left ventricular hypertrophy in 6 (13.6%, sinus bradycardia in 4 (9.1%, sinus tachycardia in 3 (6.8%, and conduction disorder in 3 (6.8%. The patients had elevated mean serum levels of creatine phosphokinase, aspartate aminotransferases, and gamma glutamyl transferase, as well as hypocalcemia and low levels of total cholesterol and LDL-cholesterol. The patients with altered electrocardiograms had a more elevated age, a lower alcohol consumption, hypopotassemia, and significantly elevated levels of triglycerides, postprandial glucose, sodium and gamma glutamyl transferase than those with normal electrocardiograms. The opposite occurred with fasting glycemia, magnesium, and alanine aminotransferase. CONCLUSION: The electrocardiographic changes found were prolonged QTc interval, change in ventricular repolarization, and left ventricular hypertrophy. Patients with normal and abnormal electrocardiograms had different metabolic and electrolytic changes.

  8. Development of Noninvasive Classification Methods for Different Roasting Degrees of Coffee Beans Using Hyperspectral Imaging.

    Science.gov (United States)

    Chu, Bingquan; Yu, Keqiang; Zhao, Yanru; He, Yong

    2018-04-19

    This study aimed to develop an approach for quickly and noninvasively differentiating the roasting degrees of coffee beans using hyperspectral imaging (HSI). The qualitative properties of seven roasting degrees of coffee beans (unroasted, light, moderately light, light medium, medium, moderately dark, and dark) were assayed, including moisture, crude fat, trigonelline, chlorogenic acid, and caffeine contents. These properties were influenced greatly by the respective roasting degree. Their hyperspectral images (874⁻1734 nm) were collected using a hyperspectral reflectance imaging system. The spectra of the regions of interest were manually extracted from the HSI images. Then, principal components analysis was employed to compress the spectral data and select the optimal wavelengths based on loading weight analysis. Meanwhile, the random frog (RF) methodology and the successive projections algorithm were also adopted to pick effective wavelengths from the spectral data. Finally, least squares support vector machine (LS-SVM) was utilized to establish discriminative models using spectral reflectance and corresponding labeled classes for each degree of roast sample. The results showed that the LS-SVM model, established by the RF selecting method, with eight wavelengths performed very well, achieving an overall classification accuracy of 90.30%. In conclusion, HSI was illustrated as a potential technique for noninvasively classifying the roasting degrees of coffee beans and might have an important application for the development of nondestructive, real-time, and portable sensors to monitor the roasting process of coffee beans.

  9. Optimal Non-Invasive Fault Classification Model for Packaged Ceramic Tile Quality Monitoring Using MMW Imaging

    Science.gov (United States)

    Agarwal, Smriti; Singh, Dharmendra

    2016-04-01

    Millimeter wave (MMW) frequency has emerged as an efficient tool for different stand-off imaging applications. In this paper, we have dealt with a novel MMW imaging application, i.e., non-invasive packaged goods quality estimation for industrial quality monitoring applications. An active MMW imaging radar operating at 60 GHz has been ingeniously designed for concealed fault estimation. Ceramic tiles covered with commonly used packaging cardboard were used as concealed targets for undercover fault classification. A comparison of computer vision-based state-of-the-art feature extraction techniques, viz, discrete Fourier transform (DFT), wavelet transform (WT), principal component analysis (PCA), gray level co-occurrence texture (GLCM), and histogram of oriented gradient (HOG) has been done with respect to their efficient and differentiable feature vector generation capability for undercover target fault classification. An extensive number of experiments were performed with different ceramic tile fault configurations, viz., vertical crack, horizontal crack, random crack, diagonal crack along with the non-faulty tiles. Further, an independent algorithm validation was done demonstrating classification accuracy: 80, 86.67, 73.33, and 93.33 % for DFT, WT, PCA, GLCM, and HOG feature-based artificial neural network (ANN) classifier models, respectively. Classification results show good capability for HOG feature extraction technique towards non-destructive quality inspection with appreciably low false alarm as compared to other techniques. Thereby, a robust and optimal image feature-based neural network classification model has been proposed for non-invasive, automatic fault monitoring for a financially and commercially competent industrial growth.

  10. Development of Noninvasive Classification Methods for Different Roasting Degrees of Coffee Beans Using Hyperspectral Imaging

    Science.gov (United States)

    Chu, Bingquan; Yu, Keqiang; Zhao, Yanru

    2018-01-01

    This study aimed to develop an approach for quickly and noninvasively differentiating the roasting degrees of coffee beans using hyperspectral imaging (HSI). The qualitative properties of seven roasting degrees of coffee beans (unroasted, light, moderately light, light medium, medium, moderately dark, and dark) were assayed, including moisture, crude fat, trigonelline, chlorogenic acid, and caffeine contents. These properties were influenced greatly by the respective roasting degree. Their hyperspectral images (874–1734 nm) were collected using a hyperspectral reflectance imaging system. The spectra of the regions of interest were manually extracted from the HSI images. Then, principal components analysis was employed to compress the spectral data and select the optimal wavelengths based on loading weight analysis. Meanwhile, the random frog (RF) methodology and the successive projections algorithm were also adopted to pick effective wavelengths from the spectral data. Finally, least squares support vector machine (LS-SVM) was utilized to establish discriminative models using spectral reflectance and corresponding labeled classes for each degree of roast sample. The results showed that the LS-SVM model, established by the RF selecting method, with eight wavelengths performed very well, achieving an overall classification accuracy of 90.30%. In conclusion, HSI was illustrated as a potential technique for noninvasively classifying the roasting degrees of coffee beans and might have an important application for the development of nondestructive, real-time, and portable sensors to monitor the roasting process of coffee beans. PMID:29671781

  11. Development of Noninvasive Classification Methods for Different Roasting Degrees of Coffee Beans Using Hyperspectral Imaging

    Directory of Open Access Journals (Sweden)

    Bingquan Chu

    2018-04-01

    Full Text Available This study aimed to develop an approach for quickly and noninvasively differentiating the roasting degrees of coffee beans using hyperspectral imaging (HSI. The qualitative properties of seven roasting degrees of coffee beans (unroasted, light, moderately light, light medium, medium, moderately dark, and dark were assayed, including moisture, crude fat, trigonelline, chlorogenic acid, and caffeine contents. These properties were influenced greatly by the respective roasting degree. Their hyperspectral images (874–1734 nm were collected using a hyperspectral reflectance imaging system. The spectra of the regions of interest were manually extracted from the HSI images. Then, principal components analysis was employed to compress the spectral data and select the optimal wavelengths based on loading weight analysis. Meanwhile, the random frog (RF methodology and the successive projections algorithm were also adopted to pick effective wavelengths from the spectral data. Finally, least squares support vector machine (LS-SVM was utilized to establish discriminative models using spectral reflectance and corresponding labeled classes for each degree of roast sample. The results showed that the LS-SVM model, established by the RF selecting method, with eight wavelengths performed very well, achieving an overall classification accuracy of 90.30%. In conclusion, HSI was illustrated as a potential technique for noninvasively classifying the roasting degrees of coffee beans and might have an important application for the development of nondestructive, real-time, and portable sensors to monitor the roasting process of coffee beans.

  12. Transient electrocardiographic abnormalities following blunt chest trauma in a child

    NARCIS (Netherlands)

    Udink ten Cate, Floris; Heerde, van Marc; Rammeloo, Lukas; Hruda, Jaroslav

    2008-01-01

    Blunt cardiac injury may occur in patients after suffering nonpenetrating trauma of the chest. It encompasses a wide spectrum of cardiac injury with varied severity and clinical presentation. Electrocardiographic abnormalities are frequently encountered. This article presents a case of a child

  13. Dynamic electrocardiographic changes in patients with arrhythmogenic right ventricular cardiomyopathy.

    LENUS (Irish Health Repository)

    Quarta, Giovanni

    2010-04-01

    Electrocardiographic (ECG) abnormalities of depolarisation and repolarisation contribute to the diagnostic criteria for arrhythmogenic right ventricular cardiomyopathy (ARVC). The development of diagnostic ECG features were investigated in a genotyped cohort with ARVC to provide more sensitive markers of early disease.

  14. Non-invasive imaging technics for diagnosis in children with surgical abdominal diseases

    International Nuclear Information System (INIS)

    Nakada, Koonosuke; Sato, Yutaka; Shimoyamada, Hiroaki; Kim, Yoshitaka; Ishikawa, Misao

    1984-01-01

    The usefullness of non-invasive imaging technics namely CT and ultrasonography was evaluated in pediatric surgical abdominal diseases, under the categoly of A) inflammatory masses (10), B) biliary abnormalities (6), C) neoplasms (12), and D) blunt abdominal traumas (8), which were experienced at St. Marianna University Hospital from April 1978 to January 1982. According to the results of the clinical study, the plan of useful diagnostic approaches in each group by means of several imaging technics was outlined. In group A and B, ultrasonography is usually suffice for diagnosis and therapy planning, whereas in group C and D, in addition to the ultrasound, CT is sometimes required for evaluating the involvement of vascular structures and sorrounding vital structures in cases of neoplasm, and coexisting injuries in the traumas. (author)

  15. Noninvasive Quantitative Imaging of Collagen Microstructure in Three-Dimensional Hydrogels Using High-Frequency Ultrasound.

    Science.gov (United States)

    Mercado, Karla P; Helguera, María; Hocking, Denise C; Dalecki, Diane

    2015-07-01

    Collagen I is widely used as a natural component of biomaterials for both tissue engineering and regenerative medicine applications. The physical and biological properties of fibrillar collagens are strongly tied to variations in collagen fiber microstructure. The goal of this study was to develop the use of high-frequency quantitative ultrasound to assess collagen microstructure within three-dimensional (3D) hydrogels noninvasively and nondestructively. The integrated backscatter coefficient (IBC) was employed as a quantitative ultrasound parameter to detect, image, and quantify spatial variations in collagen fiber density and diameter. Collagen fiber microstructure was varied by fabricating hydrogels with different collagen concentrations or polymerization temperatures. IBC values were computed from measurements of the backscattered radio-frequency ultrasound signals collected using a single-element transducer (38-MHz center frequency, 13-47 MHz bandwidth). The IBC increased linearly with increasing collagen concentration and decreasing polymerization temperature. Parametric 3D images of the IBC were generated to visualize and quantify regional variations in collagen microstructure throughout the volume of hydrogels fabricated in standard tissue culture plates. IBC parametric images of corresponding cell-embedded collagen gels showed cell accumulation within regions having elevated collagen IBC values. The capability of this ultrasound technique to noninvasively detect and quantify spatial differences in collagen microstructure offers a valuable tool to monitor the structural properties of collagen scaffolds during fabrication, to detect functional differences in collagen microstructure, and to guide fundamental research on the interactions of cells and collagen matrices.

  16. Infarct-like acute myocarditis: relation between electrocardiographic findings and myocardial damage as assessed by cardiac magnetic resonance imaging.

    Science.gov (United States)

    Nucifora, Gaetano; Miani, Daniela; Di Chiara, Antonio; Piccoli, Gianluca; Artico, Jessica; Puppato, Michela; Slavich, Gianaugusto; De Biasio, Marzia; Gasparini, Daniele; Proclemer, Alessandro

    2013-03-01

    Acute myocarditis (AM) may occasionally have an infarct-like presentation. The aim of the present study was to investigate the relation between electrocardiographic (ECG) findings in this group of patients and myocardial damage assessed by cardiac magnetic resonance imaging (MRI) with the late gadolinium enhancement (LGE) technique. Myocardial damage may be associated with ECG changes in infarct-like AM. Forty-one consecutive patients (36 males; mean age, 36 ± 12 years) with diagnosis of AM according to cardiac MRI Lake Louise criteria and infarct-like presentation were included. The relation between site of ST-segment elevation (STE), sum of STE (sumSTE), time to normalization of STE, and development of negative T wave with the extent of LGE (expressed as % of left ventricular mass [%LV LGE]), was evaluated. Most (80%) patients presented with inferolateral STE; mean sumSTE was 5 ± 3 mm. Normalization of STE occurred within 24 hours in 20 (49%) patients. Development of negative T wave occurred in 28 (68%) patients. Cardiac MRI showed LGE in all patients; mean %LV LGE was 9.6 ± 7.2%. Topographic agreement between site of STE and LGE was 68%. At multivariate analysis, sumSTE (β = 0.42, P 24 hours (β = 0.39, P 24 hours, and development of negative T wave) may help to identify patients with larger areas of myocardial damage. © 2012 Wiley Periodicals, Inc.

  17. Novel Noninvasive Brain Disease Detection System Using a Facial Image Sensor

    Directory of Open Access Journals (Sweden)

    Ting Shu

    2017-12-01

    Full Text Available Brain disease including any conditions or disabilities that affect the brain is fast becoming a leading cause of death. The traditional diagnostic methods of brain disease are time-consuming, inconvenient and non-patient friendly. As more and more individuals undergo examinations to determine if they suffer from any form of brain disease, developing noninvasive, efficient, and patient friendly detection systems will be beneficial. Therefore, in this paper, we propose a novel noninvasive brain disease detection system based on the analysis of facial colors. The system consists of four components. A facial image is first captured through a specialized sensor, where four facial key blocks are next located automatically from the various facial regions. Color features are extracted from each block to form a feature vector for classification via the Probabilistic Collaborative based Classifier. To thoroughly test the system and its performance, seven facial key block combinations were experimented. The best result was achieved using the second facial key block, where it showed that the Probabilistic Collaborative based Classifier is the most suitable. The overall performance of the proposed system achieves an accuracy −95%, a sensitivity −94.33%, a specificity −95.67%, and an average processing time (for one sample of <1 min at brain disease detection.

  18. Electrocardiographically and symptomatically silent myocardial ischemia during exercise testing

    International Nuclear Information System (INIS)

    Kurata, Chinori; Tawarahara, Kei; Sakata, Kazuyuki; Taguchi, Takahisa; Fukumoto, Yoshihiro; Kobayashi, Akira; Yamazaki, Noboru; Tanaka, Hiroshi

    1991-01-01

    Certain patients with coronary artery disease (CAD) may have neither ST depression nor chest pain during exercise despite the presence of myocardial ischemia. The frequency and characteristics of such electrocardiographically and symptomatically silent ischemia were studied in 171 patients with both angiographically documented CAD and scintigraphically documented ischemia. Fifty-six (33%) of 171 patients had neither ST depression nor chest pain (Group N), and 115 (67%) had ST depression and/or chest pain (Group P). The two groups were similar with respect to age, gender, the prevalence of prior infarction, and peak systolic blood pressure. Group N patients, however, had a higher mean peak heart rate and rate-pressure product, less severe scintigraphic ischemia, a lower lung thallium-201 uptake, and a smaller number of diseased vessels. Stepwise discriminant analysis showed a history of effort angina, lung thallium-201 uptake, and scintigraphic severity of ischemia to be significant discriminators between Groups N and P. In conclusion, electrocardiographically and symptomatically silent ischemia may be common during exercise in patients with CAD, and less severe ischemia may be one of important determinants. (author)

  19. Non-Invasive Imaging Method of Microwave Near Field Based on Solid State Quantum Sensing

    OpenAIRE

    Yang, Bo; Du, Guanxiang; Dong, Yue; Liu, Guoquan; Hu, Zhenzhong; Wang, Yongjin

    2018-01-01

    In this paper, we propose a non-invasive imaging method of microwave near field using a diamond containing nitrogen-vacancy centers. We applied synchronous pulsed sequence combined with charge coupled device camera to measure the amplitude of the microwave magnetic field. A full reconstruction formulation of the local field vector, including the amplitude and phase, is developed by measuring both left and right circular polarizations along the four nitrogen-vacancy axes. Compared to the raste...

  20. Pioglitazone modulates vascular inflammation in atherosclerotic rabbits : noninvasive assessment with FDG-PET-CT and dynamic contrast-enhanced MR imaging

    NARCIS (Netherlands)

    Vucic, E.; Dickson, S.D.; Calcagno, C.; Rudd, J.H.F.; Moshier, E.; Hayashi, K.; Mounessa, J.S.; Roytman, M.; Moon, M.J.; Lin, J.; Tsimikas, S.; Fisher, E.A.; Nicolay, K.; Fuster, V.; Fayad, Z.A.

    2011-01-01

    Objectives We sought to determine the antiatherosclerotic properties of pioglitazone using multimethod noninvasive imaging techniques. Background Inflammation is an essential component of vulnerable or high-risk atheromas. Pioglitazone, a peroxisome proliferator-activated receptor-gamma agonist,

  1. Stop the Noise: A Quality Improvement Project to Decrease Electrocardiographic Nuisance Alarms.

    Science.gov (United States)

    Sendelbach, Sue; Wahl, Sharon; Anthony, Anita; Shotts, Pam

    2015-08-01

    As many as 99% of alarm signals may not need any intervention and can result in patients' deaths. Alarm management is now a Joint Commission National Patient Safety Goal. To reduce the number of nuisance electrocardiographic alarm signals in adult patients on the medical cardiovascular care unit. A quality improvement process was used that included eliminating duplicative alarms, customizing alarms, changing electrocardiography electrodes daily, standardizing skin preparation, and using disposable electrocardiography leads. In the cardiovascular care unit, the mean number of electrocardiographic alarm signals per day decreased from 28.5 (baseline) to 3.29, an 88.5% reduction. Use of a bundled approach to managing alarm signals decreased the mean number of alarm signals in a cardiovascular care unit. ©2015 American Association of Critical-Care Nurses.

  2. Analysis of Long-Term Electrocardiographic Data in a Rabbit Model of Heart Failure

    National Research Council Canada - National Science Library

    Schuckers, Stephanie

    2001-01-01

    ... was progressively induced with doxorubicin in a rabbit model, and electrocardiographic progressions from normal state to diseased state were continuously tracked, Automated methods for analyzing...

  3. Technetium-99m labeled antisense oligonucleotide-noninvasive tumor imaging in mice

    International Nuclear Information System (INIS)

    Qin, G.M.; Zhang, Y.X.; An, R.; Gao, Z.R.; Cao, W.; Cao, G.X.; Hnatowich, D.J.

    2002-01-01

    Single-stranded RNA and DNA oligonucleotides may be useful as radiopharmaceuticals for antisense and other in vivo applications if convenient methods for stably attaching radionuclides such as 99m Tc can be developed. The c-myc oncogene works in cooperation with other oncogenes in a variety of malignant tumors. The concentration of c-myc messenger RNA increases rapidly 30 to 50 fold during DNA synthesis, thus making it a suitable target for following the progression of malignancy by noninvasive imaging with radiolabeled antisense oligonucleotide probes. Methods: 1 Oligonucleotide Conjugation: A solution of single stranded amine-derivatized DNA (100-1000μg) was prepared at a concentration of 2 mg/ml in 0.25M sodium bicarbonate, 1 M sodium chloride, 1mM EDTA, pH8.5. 2 Oligonucleotide Labeling: A fresh 50mg/ml solution of sodium tartrate was prepared in sterile 0.5 M ammonium The ability of the labeled DNA to hybridize to its complement was analyzed by Sep-Pak column chromatography before and after the addition of the complementary DNA. 3 Biodistribution and Tumor Imaging Studies: A colony of KM mice (15-20g) were inoculated with 1x10 6 Ehrlich carcinoma tumor cells in the right thigh, and the tumors were allowed to grow for 6-7 days to a size of 1.0-1.5 cm in diameter. Biodistribution studies were performed in 32 KM mice after 50 μCi per mouse of 99m Tc-labeled oncogene probes were injected intravenously. A total of 8 mice were injected intravenously in the tail vein with 1-2 mCi of 99m Tc-labeled sense or antisense probes, immobilized with ketamine hydrochloride and imaged periodically from 0.5hr to 24hr with a gamma camera. Results: Essentially complete conjugation was achieved by reverse-phase Sep-Pak C18 chromatography analysis. The labeled antisense DNA still remained the ability to hybridize with its complementary DNA. The highest accumulation of label was in the liver first, with the kidney and small bowel next. The injected activity localized in the lesion

  4. Dynamic tissue phantoms and their use in assessment of a noninvasive optical plethysmography imaging device

    Science.gov (United States)

    Thatcher, Jeffrey E.; Plant, Kevin D.; King, Darlene R.; Block, Kenneth L.; Fan, Wensheng; DiMaio, J. Michael

    2014-05-01

    Non-contact photoplethysmography (PPG) has been studied as a method to provide low-cost and non-invasive medical imaging for a variety of near-surface pathologies and two dimensional blood oxygenation measurements. Dynamic tissue phantoms were developed to evaluate this technology in a laboratory setting. The purpose of these phantoms was to generate a tissue model with tunable parameters including: blood vessel volume change; pulse wave frequency; and optical scattering and absorption parameters. A non-contact PPG imaging system was evaluated on this model and compared against laser Doppler imaging (LDI) and a traditional pulse oximeter. Results indicate non-contact PPG accurately identifies pulse frequency and appears to identify signals from optically dense phantoms with significantly higher detection thresholds than LDI.

  5. Syntheses of Radioiodinated Pyrimidine-2,4,6-Triones as Potential Agents for Non-Invasive Imaging of Matrix Metalloproteinases

    Directory of Open Access Journals (Sweden)

    Hans-Jörg Breyholz

    2017-05-01

    Full Text Available Dysregulated expression or activation of matrix metalloproteinases (MMPs is observed in many kinds of live-threatening diseases. Therefore, MMP imaging for example with radiolabelled MMP inhibitors (MMPIs potentially represents a valuable tool for clinical diagnostics using non-invasive single photon emission computed tomography (SPECT or positron emission tomography (PET imaging. This work includes the organic chemical syntheses and in vitro evaluation of five iodinated barbiturate based MMPIs and the selection of derivative 9 for radiosyntheses of isotopologues [123I]9 potentially useful for MMP SPECT imaging and [124I]9 for MMP PET imaging.

  6. 5th German cardiodiagnostic meeting 2013 with the 6th Leipzig Symposium on non-invasive cardiovascular imaging. Challenges and limit of the non-invasive cardiac imaging; 5. Deutsche Kardiodiagnostik-Tage 2013 mit 6. Leipziger Symposium Nichtinvasive Kardiovaskulaere Bildgebung. Herausforderungen und Grenzen der nicht-invasiven kardialen Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-04-01

    The proceedings on the German cardiodiagnostic meeting 2013 together with the 6th Leipzig Symposium on non-invasive cardiovascular imaging include abstracts concerning the following topics: Imaging in the rhythmology; adults with congenital cardiac defects; cardiac myopathies - myocarditis; cardiac valves (before and after transcutaneous valve replacement); coronary heart diseases; technical developments.

  7. Computing volume potentials for noninvasive imaging of cardiac excitation.

    Science.gov (United States)

    van der Graaf, A W Maurits; Bhagirath, Pranav; van Driel, Vincent J H M; Ramanna, Hemanth; de Hooge, Jacques; de Groot, Natasja M S; Götte, Marco J W

    2015-03-01

    In noninvasive imaging of cardiac excitation, the use of body surface potentials (BSP) rather than body volume potentials (BVP) has been favored due to enhanced computational efficiency and reduced modeling effort. Nowadays, increased computational power and the availability of open source software enable the calculation of BVP for clinical purposes. In order to illustrate the possible advantages of this approach, the explanatory power of BVP is investigated using a rectangular tank filled with an electrolytic conductor and a patient specific three dimensional model. MRI images of the tank and of a patient were obtained in three orthogonal directions using a turbo spin echo MRI sequence. MRI images were segmented in three dimensional using custom written software. Gmsh software was used for mesh generation. BVP were computed using a transfer matrix and FEniCS software. The solution for 240,000 nodes, corresponding to a resolution of 5 mm throughout the thorax volume, was computed in 3 minutes. The tank experiment revealed that an increased electrode surface renders the position of the 4 V equipotential plane insensitive to mesh cell size and reduces simulated deviations. In the patient-specific model, the impact of assigning a different conductivity to lung tissue on the distribution of volume potentials could be visualized. Generation of high quality volume meshes and computation of BVP with a resolution of 5 mm is feasible using generally available software and hardware. Estimation of BVP may lead to an improved understanding of the genesis of BSP and sources of local inaccuracies. © 2014 Wiley Periodicals, Inc.

  8. A comparative study for the echo cardiographic, radiologic and electrocardiographic presentation of the sport heart hypertrophy

    International Nuclear Information System (INIS)

    Reinke, A.

    1982-01-01

    In this work the three most important non-invasive methods - X-ray pictures, electrocardiography and echo cardiography - were compared as to their ability to evaluate the physiological heart enlargement as a result of physical training. Important also was the study of the value of ultrasonic cardiographs. The subjects used were 162 athletes, 36 patients with cardiovascular diseases, and 22 non-athletic control persons. Radiologically the changes in the total size of the heart were determined. For the question of the adapting reaction of the heart because of athletic training the weight-related heart volume is more meaningful than the absolute value. Electrocardiographically it is not possible to come up with any statistically significant statements about the physiological heart enlargement using the Sokoloff-Lyon indexes. Echo cardiographically the regulative heart enlargements can be differentiated into myocardial hypertrophy or ventricular dilation. As a result of this a line can be drawn between physiological and pathological changes. Female athletes show qualitatively, but not quantitatively, the same adapting reaction. The synopsis of the three procedures shows that echo cardiography and radiology show better results than does electrocardiography. Together the methods complement each other in their diagnostic power. (orig./TRV) [de

  9. Quantitative non-invasive intracellular imaging of Plasmodium falciparum infected human erythrocytes

    International Nuclear Information System (INIS)

    Edward, Kert; Farahi, Faramarz

    2014-01-01

    Malaria is a virulent pathological condition which results in over a million annual deaths. The parasitic agent Plasmodium falciparum has been extensively studied in connection with this epidemic but much remains unknown about its development inside the red blood cell host. Optical and fluorescence imaging are among the two most common procedures for investigating infected erythrocytes but both require the introduction of exogenous contrast agents. In this letter, we present a procedure for the non-invasive in situ imaging of malaria infected red blood cells. The procedure is based on the utilization of simultaneously acquired quantitative phase and independent topography data to extract intracellular information. Our method allows for the identification of the developmental stages of the parasite and facilitates in situ analysis of the morphological changes associated with the progression of this disease. This information may assist in the development of efficacious treatment therapies for this condition. (letters)

  10. Electrocardiographic evaluation in dogs of the Military Police of Rio de Janeiro

    Directory of Open Access Journals (Sweden)

    Alex Moreira de Lima

    2016-11-01

    Full Text Available ABSTRACT. Lima A.M., Ferreira L.T., Silva S.C., Jorge S.F., Ramos M.T., Pascon J.P.E., Moreira R.M. & Abidu-Figueiredo M. [Electrocardiographic evaluation in dogs of the Military Police of Rio de Janeiro.] Avaliação eletrocardiográfica em cães da Polícia Militar do Estado do Rio de Janeiro. Revista Brasileira de Medicina Veterinária, 38(Supl.2:61-66, 2016. Universidade Federal Rural do Rio de Janeiro, BR 465, Km 7, Seropédica, RJ 23897-970, Brasil. E-mail: marceloabidu@gmail.com In Rio de Janeiro, the Army, the Military Police and the Municipal Guard use dogs for routine patrol and detection of drugs, weapons, explosives and people. The most used breeds are German Shepherd, Labrador Retriever, Malinois Belgian Shepherd, Dutch Shepherd, and Doberman. Although these animals follow a protocol of physical activity, the kennel does not include a routine cardiovascular assessment and preventive hematologic exams. Forty four adult dogs were used, 13 Labrador Retrievers, 12 Malinois Belgian Shepherds, 10 German Shepherds, eight Dobermans and five Dutch Shepherds, all clinically healthy and from the Military Police Battalion of Action with Dogs of the Rio de Janeiro state. The animals underwent computed electrocardiographic and hematological evaluations. All electrocardiographic variables were correlated with body weight. Among the five breeds evaluated in the present study, only the Labrador breed showed a positive correlation between the duration of the QT interval and weight. The other electrocardiographic variables did not show any correlation with body weight. There were differences in the electrical shaft angle in Dobermann breed dogs. Labrador breed dogs showed the highest values for P wave amplitude and the breed Dobermann the lowest values. Breed dogs Labrador and German Shepherd showed the highest values for R wave amplitude and the breed Dobermann the lowest values. The QT segment as Labrador breed dogs is directly proportional to body

  11. Noninvasive measurement of renal blood flow by magnetic resonance imaging in rats.

    Science.gov (United States)

    Romero, Cesar A; Cabral, Glauber; Knight, Robert A; Ding, Guangliang; Peterson, Edward L; Carretero, Oscar A

    2018-01-01

    Renal blood flow (RBF) provides important information regarding renal physiology and nephropathies. Arterial spin labeling-magnetic resonance imaging (ASL-MRI) is a noninvasive method of measuring blood flow without exogenous contrast media. However, low signal-to-noise ratio and respiratory motion artifacts are challenges for RBF measurements in small animals. Our objective was to evaluate the feasibility and reproducibility of RBF measurements by ASL-MRI using respiratory-gating and navigator correction methods to reduce motion artifacts. ASL-MRI images were obtained from the kidneys of Sprague-Dawley (SD) rats on a 7-Tesla Varian MRI system with a spin-echo imaging sequence. After 4 days, the study was repeated to evaluate its reproducibility. RBF was also measured in animals under unilateral nephrectomy and in renal artery stenosis (RST) to evaluate the sensitivity in high and low RBF models, respectively. RBF was also evaluated in Dahl salt-sensitive (SS) rats and spontaneous hypertensive rats (SHR). In SD rats, the cortical RBFs (cRBF) were 305 ± 59 and 271.8 ± 39 ml·min -1 ·100 g tissue -1 in the right and left kidneys, respectively. Retest analysis revealed no differences ( P = 0.2). The test-retest reliability coefficient was 92 ± 5%. The cRBFs before and after the nephrectomy were 296.8 ± 30 and 428.2 ± 45 ml·min -1 ·100 g tissue -1 ( P = 0.02), respectively. The kidneys with RST exhibited a cRBF decrease compared with sham animals (86 ± 17.6 vs. 198 ± 33.7 ml·min -1 ·100 g tissue -1 ; P < 0.01). The cRBFs in SD, Dahl-SS, and SHR rats were not different ( P = 0.35). We conclude that ASL-MRI performed with navigator correction and respiratory gating is a feasible and reliable noninvasive method for measuring RBF in rats.

  12. Disappearance of electrocardiographic abnormalities associated with the arrhythmic pattern of a Barlow disease after surgical mitral valve repair

    Directory of Open Access Journals (Sweden)

    Matteo Augello

    2017-04-01

    Full Text Available We describe the case of a 46-year old female with a Barlow’s disease (MVP characterized by systolic curling of posterior left ventricular (LV wall + significant mitral annular disjunction + complex ventricular arrhythmias + syncope + inverted T waves in inferolateral leads in whom a successful surgical mitral valve rapair determined the disappearance not only of the echocardiographic but also the electrocardiographic abnormalities (in particular the inferolateral T waves inversion on basal electrocardiogram and the complex basal arrhythmic pattern. This case demonstrates that electrocardiographic abnormalities may disappear after the surgical correction of the mechanical stretch imposed on the inferior LV free wall by the prolapsing mitral valve leaflets. Electrocardiographic changes remain an important and easy marker to recognize for the identification of a high-risk subgroup of MVP patients.

  13. Diagnostic electrocardiographic dyad criteria of emphysema in left ventricular hypertrophy

    Directory of Open Access Journals (Sweden)

    Lanjewar SS

    2013-11-01

    Full Text Available Swapnil S Lanjewar,1 Lovely Chhabra,1 Vinod K Chaubey,1 Saurabh Joshi,1 Ganesh Kulkarni,1 Chandrasekhar Kothagundla,1 Sudesh Kaul,1 David H Spodick21Department of Internal Medicine, 2Department of Cardiovascular Medicine, Saint Vincent Hospital, University of Massachusetts Medical School, Worcester, MA, USABackground: The electrocardiographic diagnostic dyad of emphysema, namely a combination of the frontal vertical P-vector and a narrow QRS duration, can serve as a quasidiagnostic marker for emphysema, with specificity close to 100%. We postulated that the presence of left ventricular hypertrophy in emphysema may affect the sensitivity of this electrocardiographic criterion given that left ventricular hypertrophy generates prominent left ventricular forces and may increase the QRS duration.Methods: We reviewed the electrocardiograms and echocardiograms for 73 patients with emphysema. The patients were divided into two groups based on the presence or absence of echocardiographic evidence of left ventricular hypertrophy. The P-vector, QRS duration, and forced expiratory volume in one second (FEV1 were computed and compared between the two subgroups.Results: There was no statistically significant difference in qualitative lung function (FEV1 between the subgroups. There was no statistically significant difference in mean P-vector between the subgroups. The mean QRS duration was significantly longer in patients with left ventricular hypertrophy as compared with those without left ventricular hypertrophy.Conclusion: The presence of left ventricular hypertrophy may not affect the sensitivity of the P-vector verticalization when used as a lone criterion for diagnosing emphysema. However, the presence of left ventricular hypertrophy may significantly reduce the sensitivity of the electrocardiographic diagnostic dyad in emphysema, as it causes a widening of the QRS duration.Keywords: emphysema, electrocardiogram, left ventricular hypertrophy, chronic

  14. Cardiovascular studies Hiroshima 1958-1960: Report Number 1. Electrocardiographic findings in relation to the aging process formulation of the problem

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Shoichi; Yano, Katsuhiko

    1961-03-01

    As a part of ABCC's research program to review the general hypothesis that radiation exposure may accelerate aging processes, a comparative study now is being conducted on the pattern of age changes in electrocardiographic findings for the exposed and controls. In this report, emphasis is placed on the method of formulation of this study for statistical analysis. Two aspects of aging are considered: The frequency of abnormal electrocardiographic findings. Age changes found in normal electrocardiographic tracings. The first problem is an analysis of a three dimensional cross table of prevalence of electrocardiographic abnormalities by age, exposure group and a third factor (for instance, a socioeconomic or physiological factor). In the analysis of the second problem, an aging index was established in order to analyse effectively age changes in the electrocardiographic tracings. After a study of 22 measurements, QRS axis, Q-T interval, R/sub II/, T/sub I/, SV/sub 1/, RV/sub 1/, and RV/sub 5/ amplitudes were selected and their combination was derived to attain the highest correlation with age. Preliminary analysis was conducted for males for whom data collection had been completed. In the results so far obtained, no statistically significant differences were noted between the exposure groups. However, further detailed analysis should be conducted on these data together with data for females which are now being compiled. 18 references, 4 figures, 5 tables.

  15. Non-invasive Florentine Renaissance Panel Painting Replica Structures Investigation by Using Terahertz Time-Domain Imaging (THz-TDI) Technique

    DEFF Research Database (Denmark)

    Dandolo, Corinna Ludovica Koch; Picollo, Marcello; Cucci, Costanza

    2016-01-01

    The potentials of the Terahertz Time-Domain Imaging (THz-TDI) technique for a non-invasive inspection of panel paintings have been considered in detail. The THz-TD data acquired on a replica of a panel painting made in imitation of Italian Renaissance panel paintings were processed in order to pr...

  16. Validation of Dynamic optical coherence tomography for non-invasive, in vivo microcirculation imaging of the skin

    DEFF Research Database (Denmark)

    Themstrup, L.; Welzel, Julia; Ciardo, Silvana

    2016-01-01

    Objectives: Dynamic optical coherence tomography (D-OCT) is an angiographic variation of OCT that non-invasively provides images of the in vivo microvasculature of the skin by combining conventional OCT images with flow data. The objective of this study was to investigate and report on the D.......001), and also the redness a measurements were positively correlated with the D-OCT measurements (r = 0.48; 95% CI [0.406, 0.55]). D-OCT was able to reliably image and identify morphologic changes in the vascular network consistent with the induced physiological changes of blood flow. Conclusion: This study has...... initiated validation of the use of D-OCT for imaging of skin blood flow. Our results showed that D-OCT was able to reliably image and identify changes in the skin vasculature consistent with the induced physiological blood flow changes. These basic findings support the use of D-OCT imaging for in vivo...

  17. Evaluation of non-invasive multispectral imaging as a tool for measuring the effect of systemic therapy in Kaposi sarcoma.

    Directory of Open Access Journals (Sweden)

    Jana M Kainerstorfer

    Full Text Available Diffuse multi-spectral imaging has been evaluated as a potential non-invasive marker of tumor response. Multi-spectral images of Kaposi sarcoma skin lesions were taken over the course of treatment, and blood volume and oxygenation concentration maps were obtained through principal component analysis (PCA of the data. These images were compared with clinical and pathological responses determined by conventional means. We demonstrate that cutaneous lesions have increased blood volume concentration and that changes in this parameter are a reliable indicator of treatment efficacy, differentiating responders and non-responders. Blood volume decreased by at least 20% in all lesions that responded by clinical criteria and increased in the two lesions that did not respond clinically. Responses as assessed by multi-spectral imaging also generally correlated with overall patient clinical response assessment, were often detectable earlier in the course of therapy, and are less subject to observer variability than conventional clinical assessment. Tissue oxygenation was more variable, with lesions often showing decreased oxygenation in the center surrounded by a zone of increased oxygenation. This technique could potentially be a clinically useful supplement to existing response assessment in KS, providing an early, quantitative, and non-invasive marker of treatment effect.

  18. [Non-invasive assessment of fatty liver].

    Science.gov (United States)

    Egresi, Anna; Lengyel, Gabriella; Hagymási, Krisztina

    2015-04-05

    As the result of various harmful effects (infectious agents, metabolic diseases, unhealthy diet, obesity, toxic agents, autoimmune processes) hepatic damage may develop, which can progress towards liver steatosis, and fibrosis as well. The most common etiological factors of liver damages are hepatitis B and C infection, alcohol consumption and non-alcoholic fatty liver disease. Liver biopsy is considered as the gold standard for the diagnosis of chronic liver diseases. Due to the dangers and complications of liver biopsy, studies are focused on non-invasive markers and radiological imaging for liver steatosis, progression of fatty liver, activity of the necroinflammation and the severity of the fibrosis. Authors review the possibilities of non-invasive assessment of liver steatosis. The statistical features of the probes (positive, negative predictive values, sensitivity, specificity) are reviewed. The role of radiological imaging is also discussed. Although the non-invasive methods discussed in this article are useful to assess liver steatosis, further studies are needed to validate to follow progression of the diseases and to control therapeutic response.

  19. Noninvasive prediction of left ventricular end-diastolic pressure in patients with coronary artery disease and preserved ejection fraction.

    Science.gov (United States)

    Abd-El-Aziz, Tarek A

    2012-01-01

    The aim of this study was to compare 3 different available methods for estimating left ventricular end-diastolic pressure (LVEDP) noninvasively in patients with coronary artery disease and preserved left ventricular ejection fraction (EF). We used 3 equations for noninvasive estimation of LVEDP: The equation of Mulvagh et al., LVEDP(1) = 46 - 0.22 (IVRT) - 0.10 (AFF) - 0.03 (DT) - (2 ÷ E/A) + 0.05 MAR; the equation of Stork et al., LVEDP(2) = 1.06 + 15.15 × Ai/Ei; and the equation of Abd-El-Aziz, LVEDP(3) = [0.54 (MABP) × (1 - EF)] - 2.23. ( A, A-wave velocity; AFF, atrial filling fraction; Ai, time velocity integral of A wave; DT, deceleration time; E, E-wave velocity; Ei, time velocity integral of E wave; IVRT, isovolumic relaxation time; MABP, mean arterial blood pressure; MAR, time from termination of mitral flow to the electrocardiographic R wave; Ti, time velocity integral of total wave.) LVEDP measured by catheterization was correlated with LVEDP(1) (r = 0.52, P Aziz, LVEDP = [0.54 MABP × (1 - EF)] - 2.23, appears to be the most accurate, reliable, and easily applied method for estimating LVEDP noninvasively in patients with preserved left ventricular ejection fraction and an LVEDP < 20 mm Hg. Copyright © 2012 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  20. Diagnosis of cirrhosis and portal hypertension: imaging, non-invasive markers of fibrosis and liver biopsy

    Science.gov (United States)

    Procopet, Bogdan

    2017-01-01

    Abstract The concept of ‘cirrhosis’ is evolving and it is now clear that compensated and decompensated cirrhosis are completely different in terms of prognosis. Furthermore, the term ‘advanced chronic liver disease (ACLD)’ better reflects the continuum of histological changes occurring in the liver, which continue to progress even after cirrhosis has developed, and might regress after removing the etiological factor causing the liver disease. In compensated ACLD, portal hypertension marks the progression to a stage with higher risk of clinical complication and requires an appropriate evaluation and treatment. Invasive tests to diagnose cirrhosis (liver biopsy) and portal hypertension (hepatic venous pressure gradient measurement and endoscopy) remain of crucial importance in several difficult clinical scenarios, but their need can be reduced by using different non-invasive tests in standard cases. Among non-invasive tests, the accepted use, major limitations and major benefits of serum markers of fibrosis, elastography and imaging methods are summarized in the present review. PMID:28533906

  1. Non-invasive monitoring of in vivo hydrogel degradation and cartilage regeneration by multiparametric MR imaging

    Science.gov (United States)

    Chen, Zelong; Yan, Chenggong; Yan, Shina; Liu, Qin; Hou, Meirong; Xu, Yikai; Guo, Rui

    2018-01-01

    Numerous biodegradable hydrogels for cartilage regeneration have been widely used in the field of tissue engineering. However, to non-invasively monitor hydrogel degradation and efficiently evaluate cartilage restoration in situ is still challenging. Methods: A ultrasmall superparamagnetic iron oxide (USPIO)-labeled cellulose nanocrystal (CNC)/silk fibroin (SF)-blended hydrogel system was developed to monitor hydrogel degradation during cartilage regeneration. The physicochemical characterization and biocompatibility of the hydrogel were evaluated in vitro. The in vivo hydrogel degradation and cartilage regeneration of different implants were assessed using multiparametric magnetic resonance imaging (MRI) and further confirmed by histological analysis in a rabbit cartilage defect model for 3 months. Results: USPIO-labeled hydrogels showed sufficient MR contrast enhancement and retained stability without loss of the relaxation rate. Neither the mechanical properties of the hydrogels nor the proliferation of bone-marrow mesenchymal stem cells (BMSCs) were affected by USPIO labeling in vitro. CNC/SF hydrogels with BMSCs degraded more quickly than the acellular hydrogels as reflected by the MR relaxation rate trends in vivo. The morphology of neocartilage was noninvasively visualized by the three-dimensional water-selective cartilage MRI scan sequence, and the cartilage repair was further demonstrated by macroscopic and histological observations. Conclusion: This USPIO-labeled CNC/SF hydrogel system provides a new perspective on image-guided tissue engineering for cartilage regeneration. PMID:29464005

  2. Cathodoluminescence-activated nanoimaging: noninvasive near-field optical microscopy in an electron microscope.

    Science.gov (United States)

    Bischak, Connor G; Hetherington, Craig L; Wang, Zhe; Precht, Jake T; Kaz, David M; Schlom, Darrell G; Ginsberg, Naomi S

    2015-05-13

    We demonstrate a new nanoimaging platform in which optical excitations generated by a low-energy electron beam in an ultrathin scintillator are used as a noninvasive, near-field optical scanning probe of an underlying sample. We obtain optical images of Al nanostructures with 46 nm resolution and validate the noninvasiveness of this approach by imaging a conjugated polymer film otherwise incompatible with electron microscopy due to electron-induced damage. The high resolution, speed, and noninvasiveness of this "cathodoluminescence-activated" platform also show promise for super-resolution bioimaging.

  3. Noninvasive Test Detects Cardiovascular Disease

    Science.gov (United States)

    2007-01-01

    At NASA's Jet Propulsion Laboratory (JPL), NASA-developed Video Imaging Communication and Retrieval (VICAR) software laid the groundwork for analyzing images of all kinds. A project seeking to use imaging technology for health care diagnosis began when the imaging team considered using the VICAR software to analyze X-ray images of soft tissue. With marginal success using X-rays, the team applied the same methodology to ultrasound imagery, which was already digitally formatted. The new approach proved successful for assessing amounts of plaque build-up and arterial wall thickness, direct predictors of heart disease, and the result was a noninvasive diagnostic system with the ability to accurately predict heart health. Medical Technologies International Inc. (MTI) further developed and then submitted the technology to a vigorous review process at the FDA, which cleared the software for public use. The software, patented under the name Prowin, is being used in MTI's patented ArterioVision, a carotid intima-media thickness (CIMT) test that uses ultrasound image-capturing and analysis software to noninvasively identify the risk for the major cause of heart attack and strokes: atherosclerosis. ArterioVision provides a direct measurement of atherosclerosis by safely and painlessly measuring the thickness of the first two layers of the carotid artery wall using an ultrasound procedure and advanced image-analysis software. The technology is now in use in all 50 states and in many countries throughout the world.

  4. Value of magnetic resonance imaging for the noninvasive detection of stenosis in coronary artery bypass grafts and recipient coronary arteries

    NARCIS (Netherlands)

    Langerak, Susan E.; Vliegen, Hubert W.; Jukema, J. Wouter; Kunz, Patrik; Zwinderman, Aeilko H.; Lamb, Hildo J.; van der Wall, Ernst E.; de Roos, Albert

    2003-01-01

    BACKGROUND: Magnetic resonance imaging (MRI) is a potential noninvasive diagnostic tool to detect coronary artery bypass graft stenosis, but its value in clinical practice remains to be established. We investigated the value of MRI in detecting stenotic grafts, including recipient vessels. METHODS

  5. Proceedings of Joint International Symposium on the role of noninvasive imaging modalities in clinical decision making of coronary artery disease

    International Nuclear Information System (INIS)

    Mena, I.G.; Strauss, H.W.

    1986-01-01

    This report contains ten papers on the use of noninvasive imaging in clinical diagnosis and decision making. Topics include a cost analysis of magnetic resonance imaging in medical technology, diagnostic uses of MRI in chronic coronary artery disease, clinical applications of cine computed tomography, the use of PET as a clinical tool, and the use of echocardiography in coronary artery disease. Individual papers are processed separately for the data base

  6. Thallium-201 myocardial imaging for evaluation of pulmonary hypertension

    International Nuclear Information System (INIS)

    Ikuno, Yoshiyasu

    1979-01-01

    Thallium-201 ( 201 Tl) myocardial scintigraphy (TMS) was performed in 54 patients. The images were analysed semi-quantitatively by measuring the extent of radioisotope concentration in the right ventricular free wall and the size of the right ventricular cavity. The extent of radioisotope concentration (four degrees) was expressed as the right ventricular activity score (RVAS) and the size of the right ventricular cavity (three degrees) was expressed as the right ventricular cavity score (RVCS). The scores were added for a right ventricular total score (RVTS). To establish criteria for the diagnosis of pulmonary hypertension (PH) by means of TMS, these scores were compared with the values of pulmonary arterial mean pressure (PAMP). The criteria were evaluated by comparing them with conventional criteria for electrocardiographic diagnosis of right ventricular hypertrophy. Patients with a 2-point RVAS had a significantly higher PAMP than those with a 0 or 1-point RVAS (p 201 Tl myocardial scintigrams is a useful non-invasive method for evaluating PH and its severity. (J.P.N.)

  7. 7-Tesla Magnetic Resonance Imaging Precisely and Noninvasively Reflects Inflammation and Remodeling of the Skeletal Muscle in a Mouse Model of Antisynthetase Syndrome

    Directory of Open Access Journals (Sweden)

    Clara Sciorati

    2014-01-01

    Full Text Available Inflammatory myopathies comprise heterogeneous disorders. Their etiopathogenesis is poorly understood, because of the paucity of informative experimental models and of approaches for the noninvasive study of inflamed tissues. Magnetic resonance imaging (MRI provides information about the state of the skeletal muscle that reflects various facets of inflammation and remodeling. This technique has been scarcely used in experimental models of inflammatory myopathies. We characterized the performance of MRI in a well-established mouse model of myositis and the antisynthetase syndrome, based on the immunization of wild-type mice with the amino-terminal fragment of histidyl-tRNA synthetase (HisRS. Over an eight-week period following myositis induction, MRI enabled precise identification of pathological events taking place in muscle tissue. Areas of edema and of active inflammation identified by histopathology paralleled muscle modifications detected noninvasively by MRI. Muscles changes were chronologically associated with the establishment of autoimmunity, as reflected by the development of anti-HisRS antibodies in the blood of immunized mice. MR imaging easily appreciated muscle damage and remodeling even if actual disruption of myofiber integrity (as assessed by serum concentrations of creatinine phosphokinase was limited. Thus, MR imaging represents an informative and noninvasive analytical tool for studying in vivo immune-mediated muscle involvement.

  8. 7-Tesla Magnetic Resonance Imaging Precisely and Noninvasively Reflects Inflammation and Remodeling of the Skeletal Muscle in a Mouse Model of Antisynthetase Syndrome

    Science.gov (United States)

    Sciorati, Clara; Esposito, Antonio; Campana, Lara; Canu, Tamara; Monno, Antonella; Palmisano, Anna; De Cobelli, Francesco; Del Maschio, Alessandro; Ascheman, Dana P.; Manfredi, Angelo A.; Rovere-Querini, Patrizia

    2014-01-01

    Inflammatory myopathies comprise heterogeneous disorders. Their etiopathogenesis is poorly understood, because of the paucity of informative experimental models and of approaches for the noninvasive study of inflamed tissues. Magnetic resonance imaging (MRI) provides information about the state of the skeletal muscle that reflects various facets of inflammation and remodeling. This technique has been scarcely used in experimental models of inflammatory myopathies. We characterized the performance of MRI in a well-established mouse model of myositis and the antisynthetase syndrome, based on the immunization of wild-type mice with the amino-terminal fragment of histidyl-tRNA synthetase (HisRS). Over an eight-week period following myositis induction, MRI enabled precise identification of pathological events taking place in muscle tissue. Areas of edema and of active inflammation identified by histopathology paralleled muscle modifications detected noninvasively by MRI. Muscles changes were chronologically associated with the establishment of autoimmunity, as reflected by the development of anti-HisRS antibodies in the blood of immunized mice. MR imaging easily appreciated muscle damage and remodeling even if actual disruption of myofiber integrity (as assessed by serum concentrations of creatinine phosphokinase) was limited. Thus, MR imaging represents an informative and noninvasive analytical tool for studying in vivo immune-mediated muscle involvement. PMID:24895622

  9. Major Electrocardiographic Abnormalities According to the Minnesota Coding System Among Brazilian Adults (from the ELSA-Brasil Cohort Study).

    Science.gov (United States)

    Pinto-Filho, Marcelo M; Brant, Luisa C C; Foppa, Murilo; Garcia-Silva, Kaiser B; Mendes de Oliveira, Rackel Aguiar; de Jesus Mendes da Fonseca, Maria; Alvim, Sheila; Lotufo, Paulo A; Mill, José G; Barreto, Sandhi M; Macfarlane, Peter W; Ribeiro, Antonio L P

    2017-06-15

    The electrocardiogram is a simple and useful clinical tool; nevertheless, few studies have evaluated the prevalence of electrocardiographic abnormalities in the Latin American population. This study aims to evaluate the major electrocardiographic abnormalities according to the Minnesota coding system in Brazilian adults, stratified by gender, age, race, and cardiovascular risk factors. Data from 14,424 adults (45.8% men, age 35 to 74 years) were obtained at baseline of the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil), according to standardized protocol. The electrocardiogram were obtained with the Burdick Atria 6100 machine, stored on Pyramis System, automatically coded according to the Minnesota coding system by the Glasgow University software and then manually revised. Major abnormalities were more prevalent in men than women (11.3% and 7.9%, p <0.001). These differences were consistent through the different age groups, race, and number of cardiovascular risk factors. Electrocardiographic major abnormalities were more prevalent in black participants for both men (black: 15.1%, mixed: 10.4%, white: 11.1%, p = 0.001) and women (black: 10%, mixed: 7.6%, white: 7.2%, p = 0.004). In conclusion, in this large sample of Brazilian adults, the prevalence of major electrocardiographic abnormalities was higher among men, the elderly, black, and among people with more cardiovascular risk factors. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Gold nanoparticles for non-invasive cell tracking with CT imaging

    Science.gov (United States)

    Meir, Rinat; Betzer, Oshra; Barnoy, Eran; Motiei, Menachem; Popovtzer, Rachela

    2018-02-01

    Cell-based therapies use living cells with therapeutic traits to treat various diseases. This is a beneficial alternative for diseases that existing medicine cannot cure efficiently. However, inconsistent results in clinical trials are preventing the advancement and implementation of cell-based therapy. In order to explain such results, there is a need to discover the fate of the transplanted cells. To answer this need, we developed a technique for noninvasive in vivo cell tracking, which uses gold nanoparticles as contrast agents for CT imaging. Herein, we investigate the design principles of this technique for intramuscular transplantation of therapeutic cells. Longitudinal studies were performed, demonstrating the ability to track cells over long periods of time. As few as 500 cells could be detected and a way to quantify the number of cells visualized by CT was demonstrated. This cell-tracking technology has the potential to become an essential tool in pre-clinical studies as well as in clinical trials and advance cell therapy.

  11. Noninvasive Vascular Displacement Estimation for Relative Elastic Modulus Reconstruction in Transversal Imaging Planes

    Directory of Open Access Journals (Sweden)

    Chris L. de Korte

    2013-03-01

    Full Text Available Atherosclerotic plaque rupture can initiate stroke or myocardial infarction. Lipid-rich plaques with thin fibrous caps have a higher risk to rupture than fibrotic plaques. Elastic moduli differ for lipid-rich and fibrous tissue and can be reconstructed using tissue displacements estimated from intravascular ultrasound radiofrequency (RF data acquisitions. This study investigated if modulus reconstruction is possible for noninvasive RF acquisitions of vessels in transverse imaging planes using an iterative 2D cross-correlation based displacement estimation algorithm. Furthermore, since it is known that displacements can be improved by compounding of displacements estimated at various beam steering angles, we compared the performance of the modulus reconstruction with and without compounding. For the comparison, simulated and experimental RF data were generated of various vessel-mimicking phantoms. Reconstruction errors were less than 10%, which seems adequate for distinguishing lipid-rich from fibrous tissue. Compounding outperformed single-angle reconstruction: the interquartile range of the reconstructed moduli for the various homogeneous phantom layers was approximately two times smaller. Additionally, the estimated lateral displacements were a factor of 2–3 better matched to the displacements corresponding to the reconstructed modulus distribution. Thus, noninvasive elastic modulus reconstruction is possible for transverse vessel cross sections using this cross-correlation method and is more accurate with compounding.

  12. Noninvasive ultrasound molecular imaging of the effect of statins on endothelial inflammatory phenotype in early atherosclerosis.

    Directory of Open Access Journals (Sweden)

    Elham Khanicheh

    Full Text Available BACKGROUND/OBJECTIVES: Inflammatory changes on the endothelium are responsible for leukocyte recruitment to plaques in atherosclerosis. Noninvasive assessment of treatment-effects on endothelial inflammation may be of use for managing medical therapy and developing novel therapies. We hypothesized that molecular imaging of vascular cell adhesion molecule-1 (VCAM-1 with contrast enhanced ultrasound (CEU could assess treatment effects on endothelial phenotype in early atherosclerosis. METHODS: Mice with atherosclerosis produced by gene deletion of the LDL-receptor and Apobec-1-editing protein were studied. At 12 weeks of age, mice received 8 weeks of regular chow or atorvastatin-enriched chow (10 mg/kg/day. At 20 weeks, CEU molecular imaging for aortic endothelial VCAM-1 expression was performed with VCAM-1-targeted (MB(VCAM and control microbubbles (MB(Ctr. Aortic wall thickness was assessed with high frequency ultrasound. Histology, immunohistology and Western blot were used to assess plaque burden and VCAM-1 expression. RESULTS: Plaque burden was reduced on histology, and VCAM-1 was reduced on Western blot by atorvastatin, which corresponded to less endothelial expression of VCAM-1 on immunohistology. High frequency ultrasound did not detect differences in aortic wall thickness between groups. In contrast, CEU molecular imaging demonstrated selective signal enhancement for MB(VCAM in non-treated animals (MB(VCAM 2±0.3 vs MB(Ctr 0.7±0.2, p<0.01, but not in statin-treated animals (MB(VCAM 0.8±0.2 vs MB(Ctr 1.0±0.2, p = ns; p<0.01 for the effect of statin on MB(VCAM signal. CONCLUSIONS: Non-invasive CEU molecular imaging detects the effects of anti-inflammatory treatment on endothelial inflammation in early atherosclerosis. This easily accessible, low-cost technique may be useful in assessing treatment effects in preclinical research and in patients.

  13. Insulated electrocardiographic electrodes. [without paste electrolyte

    Science.gov (United States)

    David, R. M.; Portnoy, W. A. (Inventor)

    1975-01-01

    An integrated system is disclosed including an insulated electrode and an impedance transformer which can be assembled in a small plastic housing and used for the acquisition of electrocardiographic data. The electrode may be employed without a paste electrolyte and may be attached to the body for extended usage without producing skin reaction. The electrode comprises a thin layer of suitable nontoxic dielectric material preferably deposited by radio frequency sputtering onto a conductive substrate. The impedance transformer preferably comprises an operational amplifier having an FET input stage connected in the unity gain configuration which provides a very low lower cut-off frequency, a high input impedance with a very small input bias current, a low output impedance, and a high signal-to-noise ratio.

  14. In vivo, noninvasive functional measurements of bone sarcoma using diffuse optical spectroscopic imaging

    Science.gov (United States)

    Peterson, Hannah M.; Hoang, Bang H.; Geller, David; Yang, Rui; Gorlick, Richard; Berger, Jeremy; Tingling, Janet; Roth, Michael; Gill, Jonathon; Roblyer, Darren

    2017-12-01

    Diffuse optical spectroscopic imaging (DOSI) is an emerging near-infrared imaging technique that noninvasively measures quantitative functional information in thick tissue. This study aimed to assess the feasibility of using DOSI to measure optical contrast from bone sarcomas. These tumors are rare and pose technical and practical challenges for DOSI measurements due to the varied anatomic locations and tissue depths of presentation. Six subjects were enrolled in the study. One subject was unable to be measured due to tissue contact sensitivity. For the five remaining subjects, the signal-to-noise ratio, imaging depth, optical properties, and quantitative tissue concentrations of oxyhemoglobin, deoxyhemoglobin, water, and lipids from tumor and contralateral normal tissues were assessed. Statistical differences between tumor and contralateral normal tissue were found in chromophore concentrations and optical properties for four subjects. Low signal-to-noise was encountered during several subject's measurements, suggesting increased detector sensitivity will help to optimize DOSI for this patient population going forward. This study demonstrates that DOSI is capable of measuring optical properties and obtaining functional information in bone sarcomas. In the future, DOSI may provide a means to stratify treatment groups and monitor chemotherapy response for this disease.

  15. Noninvasive Diagnosis of Coronary Artery Disease Using 12-Lead High-Frequency Electrocardiograms

    Science.gov (United States)

    Schlegel, Todd T.; Arenare, Brian

    2006-01-01

    A noninvasive, sensitive method of diagnosing certain pathological conditions of the human heart involves computational processing of digitized electrocardiographic (ECG) signals acquired from a patient at all 12 conventional ECG electrode positions. In the processing, attention is focused on low-amplitude, high-frequency components of those portions of the ECG signals known in the art as QRS complexes. The unique contribution of this method lies in the utilization of signal features and combinations of signal features from various combinations of electrode positions, not reported previously, that have been found to be helpful in diagnosing coronary artery disease and such related pathological conditions as myocardial ischemia, myocardial infarction, and congestive heart failure. The electronic hardware and software used to acquire the QRS complexes and perform some preliminary analyses of their high-frequency components were summarized in Real-Time, High-Frequency QRS Electrocardiograph (MSC- 23154), NASA Tech Briefs, Vol. 27, No. 7 (July 2003), pp. 26-28. To recapitulate, signals from standard electrocardiograph electrodes are preamplified, then digitized at a sampling rate of 1,000 Hz, then analyzed by the software that detects R waves and QRS complexes and analyzes them from several perspectives. The software includes provisions for averaging signals over multiple beats and for special-purpose nonrecursive digital filters with specific low- and high-frequency cutoffs. These filters, applied to the averaged signal, effect a band-pass operation in the frequency range from 150 to 250 Hz. The output of the bandpass filter is the desired high-frequency QRS signal. Further processing is then performed in real time to obtain the beat-to-beat root mean square (RMS) voltage amplitude of the filtered signal, certain variations of the RMS voltage, and such standard measures as the heart rate and R-R interval at any given time. A key signal feature analyzed in the present

  16. Electrocardiographic parameters of the American Miniature Horse: influence of age and sex

    Directory of Open Access Journals (Sweden)

    Bianca P. Santarosa

    2016-06-01

    Full Text Available Abstract: The veterinary cardiology has growing importance in equine medicine. There are studies of standardization of electrocardiographic parameters of many races, according to their stature and ability. However, no studies are in the literature with the American Miniature Horse. To evaluate the electrocardiogram (ECG tracing configuration of this breed at rest and to verify the influence of age and sex on ECG parameters, 203 horses including 143 females and 60 males were divided into four age groups (foals, yearlings, adults and elderly. Electrocardiographic parameters were performed by computerized electrocardiogram (TEB, and the parameters were evaluated in six leads of frontal plane (Lead I, II, III, aVR, aVL and aVF and base-apex (BA. Heart rates (HR decreased with increasing age were higher in males than in females. Sinus tachycardia followed by sinus arrhythmia was dominant in both sexes. The cardiac axis was higher in males and ranged between 120° and 150° for foals, 30° and 60° for yearlings and adults, and 60° and 90° for the elderly. The P wave was bifid in several animals. The P-wave amplitude and T-wave duration from lead II and BA were larger in males than in females. The majority of the animals exhibited ST segment depression and a negative T-wave. The most common QRS complex morphology was Qr. Differences were observed between the electrocardiographic tracings of males and females, and age influenced the ECG parameters. Therefore, this study established the ECG patterns for the American Miniature Horse breed and could be used to determine the influence of age and sex on several of the studied variables.

  17. Cardiovascular abnormalities in patients with oral cleft: a clinical-electrocardiographic-echocardiographic study

    Directory of Open Access Journals (Sweden)

    Gisele C.P. Leite

    2018-04-01

    Full Text Available OBJECTIVES: The present study aims to describe the clinical, electrocardiographic, and echocardiographic cardiological findings in a group of patients with oral clefts. METHODS: This is a prospective cross-sectional study on 70 children (age range from 13 days to 19 years with oral clefts who attended the multidisciplinary program of a university hospital from March 2013 to September 2014. The patients were evaluated by a pediatric cardiologist and underwent detailed anamnesis, physical examination, electrocardiogram, and echocardiogram. RESULTS: Sixty percent of the patients were male; 55.7% presented with cleft lip and palate, and 40.0% presented with health complaints. Comorbidities were found in 44.3%. Relevant pregnancy, neonatal, family and personal antecedents were present in 55.7%, 27.1%, 67.2%, and 24.3% of the patients, respectively. Regarding the antecedents, 15.2% of the patients presented with a cardiac murmur, 49.0% with a familial risk of developing plurimetabolic syndrome, and 6% with family antecedents of rheumatic fever. Electrocardiographic evaluation showed one case of atrioventricular block. Echocardiograms were abnormal in 35.7% of the exams, including 5 cases of mitral valve prolapse — one of which was diagnosed with rheumatic heart disease. CONCLUSION: The finding of a family risk of developing plurimetabolic syndrome and a diagnosis of rheumatic heart disease indicates that patients with oral clefts may be more prone to developing acquired heart disease. Thus, our findings highlight the importance of anamnesis and methodological triangulation (clinical-electrocardiographic-echocardiographic in the investigation of patients with oral clefts and emphasize that cardiological follow-up to evaluate acquired and/or rhythm heart diseases is necessary. This strategy permits comorbidity prevention and individualized planned treatment.

  18. Second statement of the working group on electrocardiographic diagnosis of left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Bacharova, Ljuba; Estes, E Harvey; Bang, Lia E

    2011-01-01

    The Working Group on Electrocardiographic Diagnosis of Left Ventricular Hypertrophy, appointed by the Editor of the Journal of Electrocardiology, presents the alternative conceptual model for the ECG diagnosis of left ventricular hypertrophy (LVH). It is stressed that ECG is a record of electrica...

  19. Electrocardiographic features of sarcomere mutation carriers with and without clinically overt hypertrophic cardiomyopathy

    DEFF Research Database (Denmark)

    Lakdawala, Neal K; Thune, Jens Jakob; Maron, Barry J

    2011-01-01

    In hypertrophic cardiomyopathy (HC), electrocardiographic (ECG) changes have been postulated to be an early marker of disease, detectable in sarcomere mutation carriers when left ventricular (LV) wall thickness is still normal. However, the ECG features of mutation carriers have not been fully...

  20. Non-invasive pre-clinical MR imaging of prostate tumor hypoxia for radiation therapy prognosis

    Directory of Open Access Journals (Sweden)

    Derek White

    2014-03-01

    Full Text Available Purpose: To investigate the usefulness of Oxygen-Enhanced Magnetic Resonance Imaging (OE-MRI changes in signal intensity related to oxygen challenge for predicting tumor response to radiation therapy.Methods: Dynamic MR signal changes were acquired using Varian 4.7T small animal MR scanner prior to image-guided radiation therapy (IGRT of small (n = 6 and large subcutaneous (n = 5 prostate tumors in adult male rats. An interleaved blood-oxygen level dependent (BOLD and tissue-oxygen level dependent (TOLD data acquisition or (IBT was performed using a baseline of medical air as positive control and using medical oxygen as a breathing challenge. BOLD used a 2-D multi-slice spoiled gradient-echo with multi-echo sequence. TOLD used a 2-D multi-slice spoiled gradient-echo sequence. Voxel changes in signal intensity were determined by a correlation coefficient mapping technique. Irradiation technique planned consisted of 1F × 15 Gy AP/PA or 2F × 7.5 Gy AP/PA to the gross tumor volume (GTV. Tumor growth measurements were recorded over time to assess the response to IGRT.Results: BOLD and TOLD signals variously illustrated positive or negative impulse responses in the tumor ROI due to inhaling medical oxygen. Correlation coefficient mapping demonstrated heterogeneity in tumors after inhaling medical oxygen. BOLD and TOLD signals exhibited increased changes in signal intensities after the first fraction of dose. Multi-fractionation had minimum effect until the second fraction of dose was applied. Tumor growth delays were observed when inhaling medical oxygen during IGRT.Conclusion: OE-MRI is a non-invasive imaging modality that can provide insight to the oxygen status of tumors. Observed increase percent changes in BOLD and TOLD signal intensities after the first fraction of dose suggest tumors experienced reoxygenation. OE-MRI could be used for predicting tumor response to IGRT when using medical oxygen for increasing GTV radiosensitivity, suggesting

  1. Exercise electrocardiographic variables: a critical appraisal

    International Nuclear Information System (INIS)

    Detrano, R.; Salcedo, E.; Passalacqua, M.; Friis, R.

    1986-01-01

    To compare four recently proposed methods of analyzing the exercise electrocardiogram with the conventional analysis of ST segment depression, 303 consecutive patients without myocardial infarction who had been referred for coronary arteriography underwent stress electrocardiography and stress thallium imaging. The specificity for the prediction of a greater than 50% coronary obstruction of 0.5, 1.0, 1.5 and 2.0 mm ST segment depression measured in the conventional way was 0.59, 0.73, 0.88 and 0.94, respectively. The specificity of a thallium perfusion defect was 0.79. Sensitivities of the conventional ST depressions, thallium defect, the change in the sum of the R amplitudes and the slope adjusted for heart rate increase were calculated and compared at the cited levels of specificity. R wave changes had a significantly lower sensitivity than did the conventionally analyzed ST depression at each level of specificity. Slope-adjusted ST depression had a slightly higher sensitivity than that of conventional ST depression only at a specificity of 0.73 (0.68 versus 0.65, p = 0.07). R wave-adjusted ST depression was significantly more sensitive than conventional ST depression only at a specificity of 0.94 (0.45 versus 0.36, p = 0.01). Heart rate-adjusted ST depression was more sensitive than conventional ST depression at all of the specificities except 0.59. This pattern of superior accuracy of heart rate-adjusted ST depressions was preserved for the prediction of multivessel coronary disease. Heart rate adjustment is a simpler and more accurate modification of the conventional electrocardiographic analysis than are the other three methods studied

  2. Non-invasive quality evaluation of confluent cells by image-based orientation heterogeneity analysis.

    Science.gov (United States)

    Sasaki, Kei; Sasaki, Hiroto; Takahashi, Atsuki; Kang, Siu; Yuasa, Tetsuya; Kato, Ryuji

    2016-02-01

    In recent years, cell and tissue therapy in regenerative medicine have advanced rapidly towards commercialization. However, conventional invasive cell quality assessment is incompatible with direct evaluation of the cells produced for such therapies, especially in the case of regenerative medicine products. Our group has demonstrated the potential of quantitative assessment of cell quality, using information obtained from cell images, for non-invasive real-time evaluation of regenerative medicine products. However, image of cells in the confluent state are often difficult to evaluate, because accurate recognition of cells is technically difficult and the morphological features of confluent cells are non-characteristic. To overcome these challenges, we developed a new image-processing algorithm, heterogeneity of orientation (H-Orient) processing, to describe the heterogeneous density of cells in the confluent state. In this algorithm, we introduced a Hessian calculation that converts pixel intensity data to orientation data and a statistical profiling calculation that evaluates the heterogeneity of orientations within an image, generating novel parameters that yield a quantitative profile of an image. Using such parameters, we tested the algorithm's performance in discriminating different qualities of cellular images with three types of clinically important cell quality check (QC) models: remaining lifespan check (QC1), manipulation error check (QC2), and differentiation potential check (QC3). Our results show that our orientation analysis algorithm could predict with high accuracy the outcomes of all types of cellular quality checks (>84% average accuracy with cross-validation). Copyright © 2015 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  3. Giant T-U waves precede torsades de pointes in long QT syndrome: a systematic electrocardiographic analysis in patients with acquired and congenital QT prolongation

    NARCIS (Netherlands)

    Kirchhof, Paulus; Franz, Michael R.; Bardai, Abdennasser; Wilde, Arthur M.

    2009-01-01

    This study sought to identify electrocardiographic (ECG) criteria that are associated with initiation of torsades de pointes (TdP) in patients with acquired (a-) and congenital (c-) long QT syndrome (LQTS). Electrocardiographic criteria used as risk predictors for TdP commonly rely on a prolonged QT

  4. Non-invasive In Vivo Fluorescence Optical Imaging of Inflammatory MMP Activity Using an Activatable Fluorescent Imaging Agent.

    Science.gov (United States)

    Schwenck, Johannes; Maier, Florian C; Kneilling, Manfred; Wiehr, Stefan; Fuchs, Kerstin

    2017-05-08

    This paper describes a non-invasive method for imaging matrix metalloproteinases (MMP)-activity by an activatable fluorescent probe, via in vivo fluorescence optical imaging (OI), in two different mouse models of inflammation: a rheumatoid arthritis (RA) and a contact hypersensitivity reaction (CHR) model. Light with a wavelength in the near infrared (NIR) window (650 - 950 nm) allows a deeper tissue penetration and minimal signal absorption compared to wavelengths below 650 nm. The major advantages using fluorescence OI is that it is cheap, fast and easy to implement in different animal models. Activatable fluorescent probes are optically silent in their inactivated states, but become highly fluorescent when activated by a protease. Activated MMPs lead to tissue destruction and play an important role for disease progression in delayed-type hypersensitivity reactions (DTHRs) such as RA and CHR. Furthermore, MMPs are the key proteases for cartilage and bone degradation and are induced by macrophages, fibroblasts and chondrocytes in response to pro-inflammatory cytokines. Here we use a probe that is activated by the key MMPs like MMP-2, -3, -9 and -13 and describe an imaging protocol for near infrared fluorescence OI of MMP activity in RA and control mice 6 days after disease induction as well as in mice with acute (1x challenge) and chronic (5x challenge) CHR on the right ear compared to healthy ears.

  5. Study on mass survey for cardiovascular diseases. An analysis of the electrocardiographic findings of atomic bomb survivors

    International Nuclear Information System (INIS)

    Inoue, Noriko; Harada, Hisako; Nakamura, Kenji; Fujita, Keiko; Ishida, Sakurako; Sasaki, Hideo; Ito, Chikako; Tanaka, Gaku; Maeda, Ryo.

    1996-01-01

    Electrocardiographic findings obtained at authors' center in 1993 of 12,534 survivors (5,500 males and 7,034 females), aged 47-99 y, were analyzed in relation to irradiation conditions such as distance from the explosion site by Minnesota code to give the following results. The rate of survivors without abnormalities was higher in females than in males. In males and females, there was an increasing tendency with age of the appearance of QRS high potential, ischemic electrocardiographic abnormalities, bundle-branch block and arrhythmia. The frequency of appearance of ischemic abnormalities was correlated with sex and blood pressure but not with irradiation conditions. (H.O.)

  6. Non-invasive retinal imaging in mice with fluorescent Scanning Laser Ophthalmoscopy and Fourier Domain Optical Coherence Tomography

    OpenAIRE

    Hossein-Javaheri, Nima

    2010-01-01

    Visualization of the internal structures of the retina is critical for clinical diagnosis and monitoring of pathology as well as for medical research investigating the root causes of retinal degeneration. The aim of this thesis is to develop multi-modal non-invasive imaging technology for studying retinal degeneration and gene therapy in mice. We have constructed a FD-OCT prototype and combined it with a Scanning Laser Ophthalmoscope (SLO) to permit real time alignment of the retinal field of...

  7. Non-invasive in vivo imaging of arthritis in a collagen-induced murine model with phosphatidylserine-binding near-infrared (NIR) dye.

    Science.gov (United States)

    Chan, Marion M; Gray, Brian D; Pak, Koon Y; Fong, Dunne

    2015-03-09

    Development of non-invasive molecular imaging techniques that are based on cellular changes in inflammation has been of active interest for arthritis diagnosis. This technology will allow real-time detection of tissue damage and facilitate earlier treatment of the disease, thus representing an improvement over X-rays, which detect bone damage at the advanced stage. Tracing apoptosis, an event occurring in inflammation, has been a strategy used. PSVue 794 is a low-molecular-weight, near-infrared (NIR)-emitting complex of bis(zinc2+-dipicolylamine) (Zn-DPA) that binds to phosphatidylserine (PS), a plasma membrane anionic phospholipid that becomes flipped externally upon cell death by apoptosis. In this study, we evaluated the capacity of PSVue 794 to act as an in vivo probe for non-invasive molecular imaging assessment of rheumatoid arthritis (RA) via metabolic function in murine collagen-induced arthritis, a widely adopted animal model for RA. Male DBA/1 strain mice were treated twice with chicken collagen type II in Freund's adjuvant. Their arthritis development was determined by measuring footpad thickness and confirmed with X-ray analysis and histology. In vivo imaging was performed with the NIR dye and the LI-COR Odyssey Image System. The level of emission was compared among mice with different disease severity, non-arthritic mice and arthritic mice injected with a control dye without the Zn-DPA targeting moiety. Fluorescent emission correlated reliably with the degree of footpad swelling and the manifestation of arthritis. Ex vivo examination showed emission was from the joint. Specificity of binding was confirmed by the lack of emission when arthritic mice were given the control dye. Furthermore, the PS-binding protein annexin V displaced the NIR dye from binding, and the difference in emission was numerically measurable on a scale. This report introduces an economical alternative method for assessing arthritis non-invasively in murine models. Inflammation in

  8. Noninvasive parametric blood flow imaging of head and neck tumours using [15O]H2O and PET/CT.

    Science.gov (United States)

    Komar, Gaber; Oikonen, Vesa; Sipilä, Hannu; Seppänen, Marko; Minn, Heikki

    2012-11-01

    The aim of this study was to develop a simple noninvasive method for measuring blood flow using [15O]H2O PET/CT for the head and neck area applicable in daily clinical practice. Fifteen dynamic [15O]H2O PET emission scans with simultaneous online radioactivity measurements of radial arterial blood [Blood-input functions (IFs)] were performed. Two noninvasively obtained population-based input functions were calculated by averaging all Blood-IF curves corrected for patients' body mass and injected dose [standardized uptake value (SUV)-IF] and for body surface area (BSA-IF) and injected dose. Parametric perfusion images were calculated for each set of IFs using a linearized two-compartment model, and values for several tissues were compared using Blood-IF as the gold standard. On comparing all tissues, the correlation between blood flow obtained with the invasive Blood-IF and both SUV-IF and BSA-IF was significant (R2=0.785 with P<0.001 and R2=0.813 with P<0.001, respectively). In individual tissues, the performance of the two noninvasive methods was most reliable in resting muscle and slightly less reliable in tumour and cerebellar regions. In these two tissues, only BSA-IF showed a significant correlation with Blood-IF (R2=0.307 with P=0.032 in tumours and R2=0.398 with P<0.007 in the cerebellum). The BSA-based noninvasive method enables clinically relevant delineation between areas of low and high blood flow in tumours. The blood flow of low-perfusion tissues can be reliably quantified using either of the evaluated noninvasive methods.

  9. Noninvasive imaging of coronary arteries: current and future role of multidetector row computer tomography

    International Nuclear Information System (INIS)

    Nedevska, M.; Stoinova, V.

    2006-01-01

    Full text: This review will present the current and future role of cardiac computer tomography (CCT), and particular multidetector CCT, for imaging of atherosclerotic pathologic changes of the coronary arteries. Atherosclerosis and its cardio-vascular complications represent one of the major issues of public health in industrial countries. Different imaging modalities, including invasive coronarography, have been aimed to the diagnosis of the disease, when it provokes symptomatic decrease of the blood flow. In spite of development of surgical and percutaneous methods for coronary revascularization, coronary artery disease remains the major cause of death in North America and Europe. This demonstrates the need of novel, complementary diagnostic strategies, aimed to identify asymptomatic stages as the basis of pharmacological interventions. Noninvasive coronary angiography with multidetector CT allows both assessment of luminal stenosis and subclinical disease of arterial wall. Large trails are missing now to understand and present what will be the role of this technology in the comprehensive assessment of patients, suspected of having CAD. Based on experience and current potentials we will describe how tomographic coronary imaging may eventually supplement traditional angiographic techniques in understanding the patterns of atherosclerotic CAD development

  10. Noninvasive measurement of burn wound depth applying infrared thermal imaging (Conference Presentation)

    Science.gov (United States)

    Jaspers, Mariëlle E.; Maltha, Ilse M.; Klaessens, John H.; Vet, Henrica C.; Verdaasdonk, Rudolf M.; Zuijlen, Paul P.

    2016-02-01

    In burn wounds early discrimination between the different depths plays an important role in the treatment strategy. The remaining vasculature in the wound determines its healing potential. Non-invasive measurement tools that can identify the vascularization are therefore considered to be of high diagnostic importance. Thermography is a non-invasive technique that can accurately measure the temperature distribution over a large skin or tissue area, the temperature is a measure of the perfusion of that area. The aim of this study was to investigate the clinimetric properties (i.e. reliability and validity) of thermography for measuring burn wound depth. In a cross-sectional study with 50 burn wounds of 35 patients, the inter-observer reliability and the validity between thermography and Laser Doppler Imaging were studied. With ROC curve analyses the ΔT cut-off point for different burn wound depths were determined. The inter-observer reliability, expressed by an intra-class correlation coefficient of 0.99, was found to be excellent. In terms of validity, a ΔT cut-off point of 0.96°C (sensitivity 71%; specificity 79%) differentiates between a superficial partial-thickness and deep partial-thickness burn. A ΔT cut-off point of -0.80°C (sensitivity 70%; specificity 74%) could differentiate between a deep partial-thickness and a full-thickness burn wound. This study demonstrates that thermography is a reliable method in the assessment of burn wound depths. In addition, thermography was reasonably able to discriminate among different burn wound depths, indicating its potential use as a diagnostic tool in clinical burn practice.

  11. To identify Electrocardiographic changes in severely malnourished children

    Directory of Open Access Journals (Sweden)

    neeraj eKumar

    2015-09-01

    Full Text Available AbstractAims and objective: To identify myocardial changes in severely malnourished children.Material and method: This prospective, observational study enrolled 200 children between six months- five years of age who were fulfilling WHO criteria for severe malnutrition. The parents were duly informed and explained about the study and consent was taken. The material for the present study consisted of 200 cases (120 male and 80 female children suffering from severe protein energy malnutrition according to the mentioned criteria during the period of one year. The age group of the selected cases were divided in five groups viz. <1 years,1-2 years,2-3 years,3-4 years,4-5 years. A random selection of cases was done irrespectively of caste, creed, religion, sex and socioeconomic status etc.Results: 32% cases had flat P-wave on admission, out of which 75%. 84% of cases have increased Q-Tc-Interval at admission. S-T segment was depressed only in 8% of cases. 88% of cases have altered (flat to depressed T-wave at admission. All of these changes reverted to normal upon nutritional supplementation at discharge.Conclusion: The Electrocardiographic changes may be of help in assessing the severity and prognosis of severe acute malnutrition. The reversal of electrocardiographic changes was observed after dietary therapy. Reversibility of ECG changes suggests that the cardiac changes are not permanent in nature and will not have an effect in adult life. The cardiac status as denoted by heart rate remained same even after a fortnight, suggesting that a prolonged therapy and assessment of cardiac status is warranted even after fortnight therapy.

  12. Non-invasive red light optogenetic pacing and optical coherence microscopy (OCM) imaging for drosophila melanogaster (Conference Presentation)

    Science.gov (United States)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Cardiac pacing could be a powerful tool for investigating mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, traditional electrical pacing using pacemaker requires an invasive surgical procedure. Electrical currents from the implanted electrodes can also cause damage to heart tissue, further restricting its utility. Optogenetic pacing has been developed as a promising, non-invasive alternative to electrical stimulation for controlling animal heart rhythms. It induces heart contractions by shining pulsed light on transgene-generated microbial opsins, which in turn activate the light gated ion channels in animal hearts. However, commonly used opsins in optogenetic pacing, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we performed optogenetic pacing by expression of recently engineered red-shifted microbial opsins, ReaChR and CsChrimson, in a well-established animal model, Drosophila melanogaster, using the 617 nm stimulation light pulses. The OCM technique enables non-invasive optical imaging of animal hearts with high speed and ultrahigh axial and transverse resolutions. We integrated a customized OCM system with the optical stimulation system to monitor the optogenetic pacing noninvasively. The use of red-sifted opsins enabled deeper penetration of simulating light at lower power, which is promising for applications of optogenetic pacing in mammalian cardiac pathology studies or clinical treatments in the future.

  13. Myocardial imaging in the noninvasive evaluation of patients with suspected ischemic heart disease

    International Nuclear Information System (INIS)

    Pitt, B.; Strauss, H.W.

    1976-01-01

    Three noninvasive radioactive tracer techniques for evaluating patients with ischemic heart disease are described: (1) myocardial perfusion imaging, (2) acute infarct imaging, and (3) the gated blood pool scan. Myocardial perfusion imaging with tracers that distribute in the myocardium in relation to regional blood flow allows detection of patients with transmural and nontransmural infarction by the finding of decreased tracer concentration in the affected region of the myocardium. If these tracers are injected at the time of maximal stress to patients with significant coronary arterial stenosis but without infarction, areas of transient ischemia can be identified as zones of decreased tracer concentration not found when an examination is performed at rest. Acute infarct imaging with tracers that localize in acutely damaged tissue permits separation of patients with acute myocardial necrosis from those without infarction and those with more chronic damage. The gated blood pool scan permits assessment of left ventricular function and regional wall motion. The measurement of ventricular volumes, ejection fraction and regional wall motion adds significantly to the determination of hemodynamic variables in assessing patients with acute infarction. The technique also permits detection of right ventricular dysfunction. Performance of a combination of these radioactive tracer techniques is often advantageous, particularly in patients with suspected infarction. The techniques can establish whether infarction is present, whether it is acute, where the damage is located and how extensive it is; they can also provide a measure of the effect of this damage on left ventricular function

  14. Noninvasive imaging of transplanted living functional cells transfected with a reporter estrogen receptor gene

    Energy Technology Data Exchange (ETDEWEB)

    Takamatsu, Shinji [Biomedical Imaging Research Center, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Yoshida, Fukui 910-1193 (Japan)]. E-mail: shinjit@fmsrsa.fukui-med.ac.jp; Furukawa, Takako [Biomedical Imaging Research Center, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Yoshida, Fukui 910-1193 (Japan); Mori, Tetsuya [Biomedical Imaging Research Center, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Yoshida, Fukui 910-1193 (Japan); Yonekura, Yoshiharu [Biomedical Imaging Research Center, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Yoshida, Fukui 910-1193 (Japan); Fujibayashi, Yasuhisa [Biomedical Imaging Research Center, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Yoshida, Fukui 910-1193 (Japan)

    2005-11-01

    The transplantation of functional cells such as dopaminergic cells into damaged tissue is now clinically ongoing, but at present the population of surviving cells at the transplantation site mostly cannot be noninvasively examined. To visualize surviving transplanted functional cells using a noninvasive method, we chose the estrogen receptor ligand binding domain (ERL) as a reporter molecule and 16{alpha}-[{sup 18}F]-fluoro-17{beta}-estradiol (FES) for its ligand. We used a mouse embryonic stem (ES) cell line for recipient cells as a model. To obtain ES cells that constitutively or inducibly express ERL, we transfected two types of expression vectors into EB5 parental ES cell line using the lipofection method and obtained about 30 clones for each of the two types of transfectants. Then, to examine the expression level of ERL, we performed Western blotting analysis. Ligand uptake experiments were carried out using [{sup 3}H]-estradiol with or without excessive unlabeled estradiol for control cells and ERL transfectants. Each selected clone was also used for in vivo positron emission tomography (PET) imaging studies involving FES in nude mice transplanted with control cells and ERL transfectants. In some of the clones transfected with the inducible-type ERL gene, protein was expressed much higher than in the controls. However, constitutive-type ERL gene-transfected ES cells showed no protein production in spite of their gene expression activity being considerably high. All clones also expressed equal levels of the Oct-3/4 gene, a marker of pluripotency, in comparison with the parental cells. Also, the specific uptake of [{sup 3}H]-estradiol was over 30 times higher in inducer-treated ERL-expressing ES cells compared to untreated control cells. Finally, by performing dynamic PET imaging, we successfully visualized ERL-expressing teratomas using FES.

  15. Noninvasive imaging of transplanted living functional cells transfected with a reporter estrogen receptor gene

    International Nuclear Information System (INIS)

    Takamatsu, Shinji; Furukawa, Takako; Mori, Tetsuya; Yonekura, Yoshiharu; Fujibayashi, Yasuhisa

    2005-01-01

    The transplantation of functional cells such as dopaminergic cells into damaged tissue is now clinically ongoing, but at present the population of surviving cells at the transplantation site mostly cannot be noninvasively examined. To visualize surviving transplanted functional cells using a noninvasive method, we chose the estrogen receptor ligand binding domain (ERL) as a reporter molecule and 16α-[ 18 F]-fluoro-17β-estradiol (FES) for its ligand. We used a mouse embryonic stem (ES) cell line for recipient cells as a model. To obtain ES cells that constitutively or inducibly express ERL, we transfected two types of expression vectors into EB5 parental ES cell line using the lipofection method and obtained about 30 clones for each of the two types of transfectants. Then, to examine the expression level of ERL, we performed Western blotting analysis. Ligand uptake experiments were carried out using [ 3 H]-estradiol with or without excessive unlabeled estradiol for control cells and ERL transfectants. Each selected clone was also used for in vivo positron emission tomography (PET) imaging studies involving FES in nude mice transplanted with control cells and ERL transfectants. In some of the clones transfected with the inducible-type ERL gene, protein was expressed much higher than in the controls. However, constitutive-type ERL gene-transfected ES cells showed no protein production in spite of their gene expression activity being considerably high. All clones also expressed equal levels of the Oct-3/4 gene, a marker of pluripotency, in comparison with the parental cells. Also, the specific uptake of [ 3 H]-estradiol was over 30 times higher in inducer-treated ERL-expressing ES cells compared to untreated control cells. Finally, by performing dynamic PET imaging, we successfully visualized ERL-expressing teratomas using FES

  16. Noninvasive studies of human visual cortex using neuromagnetic techniques

    International Nuclear Information System (INIS)

    Aine, C.J.; George, J.S.; Supek, S.; Maclin, E.L.

    1990-01-01

    The major goals of noninvasive studies of the human visual cortex are: to increase knowledge of the functional organization of cortical visual pathways; and to develop noninvasive clinical tests for the assessment of cortical function. Noninvasive techniques suitable for studies of the structure and function of human visual cortex include magnetic resonance imaging (MRI), positron emission tomography (PET), single photon emission tomography (SPECT), scalp recorded event-related potentials (ERPs), and event-related magnetic fields (ERFs). The primary challenge faced by noninvasive functional measures is to optimize the spatial and temporal resolution of the measurement and analytic techniques in order to effectively characterize the spatial and temporal variations in patterns of neuronal activity. In this paper we review the use of neuromagnetic techniques for this purpose. 8 refs., 3 figs

  17. Electrocardiographic reference values for healthy Netherland Dwarf rabbits and the influence of body position, age and gender

    Directory of Open Access Journals (Sweden)

    J. M. Chapel

    2017-12-01

    Full Text Available The aim of this study was to provide reference values for a single, popular breed of pet rabbit. Moreover, additional objectives were to determine whether sex, body position or age alter Netherland Dwarf rabbit electrocardiographic variables and whether the use of electrocardiographic filters affects those variables. Forty Netherland Dwarf rabbits were examined clinically and standard six-lead electrocardiograms (ECGs were recorded in sternal and then dorsal recumbency. At first power-line and anti-drift filters were used and then they were disabled. The following variables were measured in lead II: heart rate; P wave duration and amplitude; P-R interval; QRS duration; R wave amplitude (with and without filters; Q-T interval; T wave duration and amplitude; S-T segment; J-T duration; and mean electrical axis (MEA (with and without filters. MEA was determined by 3 different methods. After statistical processing of the data, our results showed that there were no significant differences between both recumbencies, with the exception of the J-T duration, which was higher in dorsal recumbency. The R wave amplitude using electrocardiographic filters showed significant differences between males (0.083 mV and females (0.115 mV; P<0.05; and between younger rabbits (0.108 mV and older rabbits (0.097 mV; P<0.05. These differences were not shown between R waves with filters disabled. Moreover, the strongest correlation was between 2 MEA methods without filters. MEA was more leftward in the pet rabbit than in other species (dog or cats. In conclusion, electrocardiography recording without electrocardiographic filters should be assessed when it is possible, and the specific ECGs characteristics for Netherland Dwarf rabbit should be taken into account.

  18. Imaging modalities for the non-invasive diagnosis of endometriosis

    NARCIS (Netherlands)

    Nisenblat, Vicki; Bossuyt, Patrick M. M.; Farquhar, Cindy; Johnson, Neil; Hull, M. Louise

    2016-01-01

    About 10% of women of reproductive age suffer from endometriosis. Endometriosis is a costly chronic disease that causes pelvic pain and subfertility. Laparoscopy, the gold standard diagnostic test for endometriosis, is expensive and carries surgical risks. Currently, no non-invasive tests that can

  19. Sex Differences in Timeliness of Reperfusion in Young Patients With ST-Segment-Elevation Myocardial Infarction by Initial Electrocardiographic Characteristics.

    Science.gov (United States)

    Gupta, Aakriti; Barrabes, Jose A; Strait, Kelly; Bueno, Hector; Porta-Sánchez, Andreu; Acosta-Vélez, J Gabriel; Lidón, Rosa-Maria; Spatz, Erica; Geda, Mary; Dreyer, Rachel P; Lorenze, Nancy; Lichtman, Judith; D'Onofrio, Gail; Krumholz, Harlan M

    2018-03-07

    Young women with ST-segment-elevation myocardial infarction experience reperfusion delays more frequently than men. Our aim was to determine the electrocardiographic correlates of delay in reperfusion in young patients with ST-segment-elevation myocardial infarction. We examined sex differences in initial electrocardiographic characteristics among 1359 patients with ST-segment-elevation myocardial infarction in a prospective, observational, cohort study (2008-2012) of 3501 patients with acute myocardial infarction, 18 to 55 years of age, as part of the VIRGO (Variation in Recovery: Role of Gender on Outcomes of Young AMI Patients) study at 103 US and 24 Spanish hospitals enrolling in a 2:1 ratio for women/men. We created a multivariable logistic regression model to assess the relationship between reperfusion delay (door-to-balloon time >90 or >120 minutes for transfer or door-to-needle time >30 minutes) and electrocardiographic characteristics, adjusting for sex, sociodemographic characteristics, and clinical characteristics at presentation. In our study (834 women and 525 men), women were more likely to exceed reperfusion time guidelines than men (42.4% versus 31.5%; P ST elevation in lateral leads was an inverse predictor of reperfusion delay. Sex disparities in timeliness to reperfusion in young patients with ST-segment-elevation myocardial infarction persisted, despite adjusting for initial electrocardiographic characteristics. Left ventricular hypertrophy by voltage criteria and absence of prehospital ECG are strongly positively correlated and ST elevation in lateral leads is negatively correlated with reperfusion delay. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  20. Steato-Score: Non-Invasive Quantitative Assessment of Liver Fat by Ultrasound Imaging.

    Science.gov (United States)

    Di Lascio, Nicole; Avigo, Cinzia; Salvati, Antonio; Martini, Nicola; Ragucci, Monica; Monti, Serena; Prinster, Anna; Chiappino, Dante; Mancini, Marcello; D'Elia, Domenico; Ghiadoni, Lorenzo; Bonino, Ferruccio; Brunetto, Maurizia R; Faita, Francesco

    2018-05-04

    Non-alcoholic fatty liver disease is becoming a global epidemic. The aim of this study was to develop a system for assessing liver fat content based on ultrasound images. Magnetic resonance spectroscopy measurements were obtained in 61 patients and the controlled attenuation parameter in 54. Ultrasound images were acquired for all 115 participants and used to calculate the hepatic/renal ratio, hepatic/portal vein ratio, attenuation rate, diaphragm visualization and portal vein wall visualization. The Steato-score was obtained by combining these five parameters. Magnetic resonance spectroscopy measurements were significantly correlated with hepatic/renal ratio, hepatic/portal vein ratio, attenuation rate, diaphragm visualization and portal vein wall visualization; Steato-score was dependent on hepatic/renal ratio, attenuation rate and diaphragm visualization. Area under the receiver operating characteristic curve was equal to 0.98, with 89% sensitivity and 94% specificity. Controlled attenuation parameter values were significantly correlated with hepatic/renal ratio, attenuation rate, diaphragm visualization and Steato-score; the area under the curve was 0.79. This system could be a valid alternative as a non-invasive, simple and inexpensive assessment of intrahepatic fat. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  1. Noninvasive photoacoustic computed tomography of mouse brain metabolism in vivo

    Science.gov (United States)

    Yao, Junjie; Xia, Jun; Maslov, Konstantin I.; Nasiriavanaki, Mohammadreza; Tsytsarev, Vassiliy; Demchenko, Alexei V.; Wang, Lihong V.

    2012-01-01

    We have demonstrated the feasibility of imaging mouse brain metabolism using photoacoustic computed tomography (PACT), a fast, noninvasive and functional imaging modality with optical contrast and acoustic resolution. Brain responses to forepaw stimulations were imaged transdermally and transcranially. 2-NBDG, which diffuses well across the blood-brain-barrier, provided exogenous contrast for photoacoustic imaging of glucose response. Concurrently, hemoglobin provided endogenous contrast for photoacoustic imaging of hemodynamic response. Glucose and hemodynamic responses were quantitatively decoupled by using two-wavelength measurements. We found that glucose uptake and blood perfusion around the somatosensory region of the contralateral hemisphere were both increased by stimulations, indicating elevated neuron activity. While the glucose response area was more homogenous and confined within the somatosensory region, the hemodynamic response area had a clear vascular pattern and spread wider than the somatosensory region. Our results demonstrate that 2-NBDG-enhanced PACT is a promising tool for noninvasive studies of brain metabolism. PMID:22940116

  2. Noninvasive diagnostic test choices for the evaluation of coronary artery disease in women: a multivariate comparison of cardiac fluoroscopy, exercise electrocardiography and exercise thallium myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Hung, J.; Chaitman, B.R.; Lam, J.; Lesperance, J.; Dupras, G.; Fines, P.; Bourassa, M.G.

    1984-01-01

    Several diagnostic noninvasive tests to detect coronary and multivessel coronary disease are available for women. However, all are imperfect and it is not yet clear whether one particular test provides substantially more information than others. The aim of this study was to evaluate clinical findings, exercise electrocardiography, exercise thallium myocardial scintigraphy and cardiac fluoroscopy in 92 symptomatic women without previous infarction and determine which tests were most useful in determining the presence of coronary disease and its severity. Univariate analysis revealed two clinical, eight exercise electrocardiographic, seven myocardial scintigraphic and seven fluoroscopic variables predictive of coronary or multivessel disease with 70% or greater stenosis. The multivariate discriminant function analysis selected a reversible thallium defect, coronary calcification and character of chest pain syndrome as the variables most predictive of presence or absence of coronary disease. The ranked order of variables most predictive of multivessel disease were cardiac fluoroscopy score, thallium score and extent of ST segment depression in 14 electrocardiographic leads. Each provided statistically significant information to the model. The estimate of predictive accuracy was 89% for coronary disease and 97% for multivessel coronary disease. The results suggest that cardiac fluoroscopy or thallium scintigraphy provide significantly more diagnostic information than exercise electrocardiography in women over a wide range of clinical patient subsets

  3. Noninvasive, low-noise, fast imaging of blood volume and deoxygenation changes in muscles using light-emitting diode continuous-wave imager

    Science.gov (United States)

    Lin, Yuanqing; Lech, Gwen; Nioka, Shoko; Intes, Xavier; Chance, Britton

    2002-08-01

    This article focuses on optimizing the signal to noise ratio (SNR) of a three-wavelength light-emitting diode (LED) near-infrared continuous-wave (cw) imager and its application to in vivo muscle metabolism measurement. The shot-noise limited SNR is derived and calculated to be 2 x104 for the physiological blood concentrations of muscle. Aiming at shot-noise limited SNR performance and fast imaging, we utilize sample and hold circuits to reduce high-frequency noise. These circuits have also been designed to be parallel integrating, through which SNR of 2 x103 and 2 Hz imaging acquisition rate have been achieved when the probe is placed on a muscle model. The noise corresponds to 2 x10-4 optical density error, which suggests an in vitro resolution of 15. 4 nM blood volume and 46.8 nM deoxygenation changes. A 48 dB digital gain control circuit with 256 steps is employed to enlarge the dynamic range of the imager. We utilize cuff ischemia as a living model demonstration and its results are reported. The instrument is applied during exercise to measure the changes of blood volume and deoxygenation, which provides important information about muscle metabolism. We find that the primary source of noise encountered during exercise experiment is from the random motion of muscle. The results demonstrate that the LED cw imager is ideal for the noninvasive study of muscle metabolism.

  4. Electrocardiographic abnormalities in opiate addicts.

    Science.gov (United States)

    Wallner, Christina; Stöllberger, Claudia; Hlavin, Anton; Finsterer, Josef; Hager, Isabella; Hermann, Peter

    2008-12-01

    To determine in a cross-sectional study the prevalence of electrocardiographic (ECG) abnormalities in opiate addicts who were therapy-seeking and its association with demographic, clinical and drug-specific parameters. In consecutive therapy-seeking opiate addicts, a 12-lead ECG was registered within 24 hours after admission and evaluated according to a pre-set protocol between October 2004 and August 2006. Additionally, demographic, clinical and drug-specific parameters were recorded. Included were 511 opiate-addicts, 25% female, with a mean age of 29 years (range 17-59 years). One or more ECG abnormalities were found in 314 patients (61%). In the 511 patients we found most commonly ST abnormalities (19%), QTc prolongation (13%), tall R- and/or S-waves (11%) and missing R progression (10%). ECG abnormalities were more common in males than in females (64 versus 54%, P seizures less often (16 versus 27%, P opiate addicts. The most frequent ECG abnormalities are ST abnormalities, QTc prolongation and tall R- and/or S-waves. ST abnormalities are associated with cannabis, and QTc prolongation with methadone and benzodiazepines.

  5. Noninvasive photoacoustic computed tomography of mouse brain metabolism in vivo

    OpenAIRE

    Yao, Junjie; Xia, Jun; Maslov, Konstantin I.; Nasiriavanaki, Mohammadreza; Tsytsarev, Vassiliy; Demchenko, Alexei V.; Wang, Lihong V.

    2012-01-01

    We have demonstrated the feasibility of imaging mouse brain metabolism using photoacoustic computed tomography (PACT), a fast, noninvasive and functional imaging modality with optical contrast and acoustic resolution. Brain responses to forepaw stimulations were imaged transdermally and transcranially. 2-NBDG, which diffuses well across the blood–brain-barrier, provided exogenous contrast for photoacoustic imaging of glucose response. Concurrently, hemoglobin provided endogenous contrast for ...

  6. Non-invasive imaging and monitoring of rodent retina using simultaneous dual-band optical coherence tomography

    Science.gov (United States)

    Cimalla, Peter; Burkhardt, Anke; Walther, Julia; Hoefer, Aline; Wittig, Dierk; Funk, Richard; Koch, Edmund

    2011-03-01

    Spectral domain dual-band optical coherence tomography for simultaneous imaging of rodent retina in the 0.8 μm and 1.3 μm wavelength region and non-invasive monitoring of the posterior eye microstructure in the field of retinal degeneration research is demonstrated. The system is illuminated by a supercontinuum laser source and allows three-dimensional imaging with high axial resolution better than 3.8 μm and 5.3 μm in tissue at 800 nm and 1250 nm, respectively, for precise retinal thickness measurements. A fan-shaped scanning pattern with the pivot point close to the eye's pupil and a contact lens are applied to obtain optical access to the eye's fundus. First in vivo experiments in a RCS (royal college of surgeons) rat model with gene-related degeneration of the photoreceptor cells show good visibility of the retinal microstructure with sufficient contrast for thickness measurement of individual retinal layers. An enhanced penetration depth at 1250 nm is clearly identifiable revealing sub-choroidal structures that are not visible at 800 nm. Furthermore, additional simultaneous imaging at 1250 nm improves image quality by frequency compounding speckle noise reduction. These results are encouraging for time course studies of the rodent retina concerning its development related to disease progression and treatment response.

  7. Non-invasive quantitative pulmonary V/Q imaging using Fourier decomposition MRI at 1.5T

    Energy Technology Data Exchange (ETDEWEB)

    Kjoerstad, Aasmund; Corteville, Dominique M.R.; Zoellner, Frank G.; Schad, Lothar R. [Heidelberg Univ., Medical Faculty Mannheim (Germany). Computer Assisted Clinical Medicine; Henzler, Thomas [Heidelberg Univ., Medical Faculty Mannheim (Germany). Inst. of Clinical Radiology and Nuclear Medicine; Schmid-Bindert, Gerald [Heidelberg Univ., Medical Faculty Mannheim (Germany). Interdisciplinary Thoracic Oncology

    2015-07-01

    Techniques for quantitative pulmonary perfusion and ventilation using the Fourier Decomposition method were recently demonstrated. We combine these two techniques and show that ventilation-perfusion (V/Q) imaging is possible using only a single MR acquisition of less than thirty seconds. The Fourier Decomposition method is used in combination with two quantification techniques, which extract baselines from within the images themselves and thus allows quantification. For the perfusion, a region assumed to consist of 100% blood is utilized, while for the ventilation the zero-frequency component is used. V/Q-imaging is then done by dividing the quantified ventilation map with the quantified perfusion map. The techniques were used on ten healthy volunteers and fifteen patients diagnosed with lung cancer. A mean V/Q-ratio of 1.15±0.22 was found for the healthy volunteers and a mean V/Q-ratio of 1.93±0.83 for the non-afflicted lung in the patients. Mean V/Q-ratio in the afflicted (tumor-bearing) lung was found to be 1.61±1.06. Functional defects were clearly visible in many of the patient images, but 5 of 15 patient images had to be excluded due to artifacts or low SNR, indicating a lack of robustness. Conclusion Non-invasive, quantitative V/Q-imaging is possible using Fourier Decomposition MRI. The method requires only a single acquisition of less than 30 seconds, but robustness in patients remains an issue.

  8. Non-invasive quantitative pulmonary V/Q imaging using Fourier decomposition MRI at 1.5T.

    Science.gov (United States)

    Kjørstad, Åsmund; Corteville, Dominique M R; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2015-12-01

    Techniques for quantitative pulmonary perfusion and ventilation using the Fourier Decomposition method were recently demonstrated. We combine these two techniques and show that ventilation-perfusion (V/Q) imaging is possible using only a single MR acquisition of less than thirty seconds. The Fourier Decomposition method is used in combination with two quantification techniques, which extract baselines from within the images themselves and thus allows quantification. For the perfusion, a region assumed to consist of 100% blood is utilized, while for the ventilation the zero-frequency component is used. V/Q-imaging is then done by dividing the quantified ventilation map with the quantified perfusion map. The techniques were used on ten healthy volunteers and fifteen patients diagnosed with lung cancer. A mean V/Q-ratio of 1.15 ± 0.22 was found for the healthy volunteers and a mean V/Q-ratio of 1.93 ± 0.83 for the non-afflicted lung in the patients. Mean V/Q-ratio in the afflicted (tumor-bearing) lung was found to be 1.61 ± 1.06. Functional defects were clearly visible in many of the patient images, but 5 of 15 patient images had to be excluded due to artifacts or low SNR, indicating a lack of robustness. Non-invasive, quantitative V/Q-imaging is possible using Fourier Decomposition MRI. The method requires only a single acquisition of less than 30 seconds, but robustness in patients remains an issue. Copyright © 2015. Published by Elsevier GmbH.

  9. "Heart rate-dependent" electrocardiographic diagnosis of left ventricular hypertrophy.

    Science.gov (United States)

    Madias, John E

    2013-05-01

    A case is presented revealing the common phenomenon of heart rate-dependent diagnosis of electrocardiographic (ECG) diagnosis of left ventricular hypertrophy (LVH), which consists of satisfaction of LVH criteria only at faster rates whereas ECGs with a slow heart rate do not satisfy such criteria. The mechanism of the phenomenon has been attributed to the tachycardia-mediated underfilling of the left ventricle bringing the electrical "centroid" of the heart closer to the recording electrodes, which results in augmentation of the amplitude of QRS complexes, particularly in leads V2-V4. ©2012, The Author. Journal compilation ©2012 Wiley Periodicals, Inc.

  10. Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.

    Science.gov (United States)

    Hynynen, Kullervo; Jones, Ryan M

    2016-09-07

    Focused ultrasound offers a non-invasive way of depositing acoustic energy deep into the body, which can be harnessed for a broad spectrum of therapeutic purposes, including tissue ablation, the targeting of therapeutic agents, and stem cell delivery. Phased array transducers enable electronic control over the beam geometry and direction, and can be tailored to provide optimal energy deposition patterns for a given therapeutic application. Their use in combination with modern medical imaging for therapy guidance allows precise targeting, online monitoring, and post-treatment evaluation of the ultrasound-mediated bioeffects. In the past there have been some technical obstacles hindering the construction of large aperture, high-power, densely-populated phased arrays and, as a result, they have not been fully exploited for therapy delivery to date. However, recent research has made the construction of such arrays feasible, and it is expected that their continued development will both greatly improve the safety and efficacy of existing ultrasound therapies as well as enable treatments that are not currently possible with existing technology. This review will summarize the basic principles, current statures, and future potential of image-guided ultrasound phased arrays for therapy.

  11. Noninvasive imaging technologies reveal edema toxin as a key virulence factor in anthrax.

    Science.gov (United States)

    Dumetz, Fabien; Jouvion, Grégory; Khun, Huot; Glomski, Ian Justin; Corre, Jean-Philippe; Rougeaux, Clémence; Tang, Wei-Jen; Mock, Michèle; Huerre, Michel; Goossens, Pierre Louis

    2011-06-01

    Powerful noninvasive imaging technologies enable real-time tracking of pathogen-host interactions in vivo, giving access to previously elusive events. We visualized the interactions between wild-type Bacillus anthracis and its host during a spore infection through bioluminescence imaging coupled with histology. We show that edema toxin plays a central role in virulence in guinea pigs and during inhalational infection in mice. Edema toxin (ET), but not lethal toxin (LT), markedly modified the patterns of bacterial dissemination leading, to apparent direct dissemination to the spleen and provoking apoptosis of lymphoid cells. Each toxin alone provoked particular histological lesions in the spleen. When ET and LT are produced together during infection, a specific temporal pattern of lesion developed, with early lesions typical of LT, followed at a later stage by lesions typical of ET. Our study provides new insights into the complex spatial and temporal effects of B. anthracis toxins in the infected host, suggesting a greater role than previously suspected for ET in anthrax and suggesting that therapeutic targeting of ET contributes to protection. Copyright © 2011 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  12. Non-invasive measurement and imaging of tissue iron oxide nanoparticle concentrations in vivo using proton relaxometry

    International Nuclear Information System (INIS)

    St Pierre, T G; Clark, P R; Chua-anusorn, W; Fleming, A; Pardoe, H; Jeffrey, G P; Olynyk, J K; Pootrakul, P; Jones, S; Moroz, P

    2005-01-01

    Magnetic nanoparticles and microparticles can be found in biological tissues for a variety of reasons including pathological deposition of biogenic particles, administration of synthetic particles for scientific or clinical reasons, and the inclusion of biogenic magnetic particles for the sensing of the geomagnetic field. In applied magnetic fields, the magnetisation of tissue protons can be manipulated with radiofrequency radiation such that the macroscopic magnetisation of the protons precesses freely in the plane perpendicular to the applied static field. The presence of magnetic particles within tissue enhances the rate of dephasing of proton precession with higher concentrations of particles resulting in higher dephasing rates. Magnetic resonance imaging instruments can be used to measure and image the rate of decay of spin echo recoverable proton transverse magnetisation (R 2 ) within tissues enabling the measurement and imaging of magnetic particle concentrations with the aid of suitable calibration curves. Applications include the non-invasive measurement of liver iron concentrations in iron-overload disorders and measurement and imaging of magnetic particle concentrations used in magnetic hyperthermia therapy. Future applications may include the tracking of magnetically labelled drugs or biomolecules and the measurement of fibrotic liver damage

  13. Near-infrared quantum-dot-based non-invasive in vivo imaging of squamous cell carcinoma U14

    International Nuclear Information System (INIS)

    Cao Yu'an; Yang Kai; Li Zhigang; Zhao Cheng; Yang Jia; Shi Chunmeng

    2010-01-01

    Near-infrared (near-ir) quantum dots (QDs) are well known for their excellent optical characteristics. They hold great potential for applications in non-invasive long term observation and tracing of cells in vivo. Here, near-ir QDs with an emission wavelength of 800 nm (QD800) were used to label squamous cell carcinoma cell line U14 (U14/QD800). The effect of tissue depth and animal fur on the imaging sensitivity and stability was evaluated following subcutaneous and intramuscular injection into Kunming mice, employing an in vivo imaging system. We have demonstrated that QD800-based visual in vivo imaging increased the sensitivity of cancer early detection by a factor of 100 compared with traditional detection methods. More importantly, this study proved for the first time that animal fur has a serious impact on the detection sensitivity and duration of QD-based in vivo imaging. In general, the duration and sensitivity of QD800 for in vivo imaging were not greatly affected by a depth less than 1.8 ± 0.21 mm (subcutaneous or intramuscular). This study provides critical reference data for further research on near-ir QD-based early detection and in vivo visual observation of cancer.

  14. Electrocardiographic features of patients with earthquake related posttraumatic stress disorder

    Science.gov (United States)

    İlhan, Erkan; Kaplan, Abdullah; Güvenç, Tolga Sinan; Biteker, Murat; Karabulut, Evindar; Işıklı, Serhan

    2013-01-01

    AIM: To analyze electrocardiographic features of patients diagnosed with posttraumatic stress disorder (PTSD) after the Van-Erciş earthquake, with a shock measuring 7.2 on the Richter scale that took place in Turkey in October 2011. METHODS: Surface electrocardiograms of 12 patients with PTSD admitted to Van Erciş State Hospital (Van, Turkey) from February 2012 to May 2012 were examined. Psychiatric interviews of the sex and age matched control subjects, who had experienced the earthquake, confirmed the absence of any known diagnosable psychiatric conditions in the control group. RESULTS: A wide range of electrocardiogram (ECG) parameters, such as P-wave dispersion, QT dispersion, QT interval, Tpeak to Tend interval, intrinsicoid deflection durations and other traditional parameters were similar in both groups. There was no one with an abnormal P wave axis, short or long PR interval, long or short QT interval, negative T wave in lateral leads, abnormal T wave axis, abnormal left or right intrinsicoid deflection duration, low voltage, left bundle branch block, right bundle branch block, left posterior hemiblock, left or right axis deviation, left ventricular hypertrophy, right or left atrial enlargement and pathological q(Q) wave in either group. CONCLUSION: The study showed no direct effect of earthquake related PTSD on surface ECG in young patients. So, we propose that PTSD has no direct effect on surface ECG but may cause electrocardiographic changes indirectly by triggering atherosclerosis and/or contributing to the ongoing atherosclerotic process. PMID:23538549

  15. The Study of Electrocardiographic Findings in Patients with Organophosphate Poisoning

    Directory of Open Access Journals (Sweden)

    Morteza Rahbar Taromsari

    2013-02-01

    Full Text Available Background: Cardiac manifestations that occur in a majority of patients with organophosphate (OP poisoning may range from innocuous electrocardiographic manifestations, such as sinus tachycardia, to life-threatening complications, including cardiogenic pulmonary edema and myocardial necrosis. In this study, we evaluated the various electrocardiographic manifestations in patients with OP poisoning. Methods: This retrospective-descriptive study was performed by reviewing the medical records from all patients poisoned with organophosphate admitted to Razi Educational Hospital, Rasht, Iran, from April 2008 to March 2011. Patients with incomplete records were excluded from the study. Histories of all patients were collected and ECG analysis was conducted including the rate, rhythm, ST-T abnormalities, conduction defects, and measurement of PR and QT intervals by a cardiologist. Descriptive statistical analysis was conducted by SPSS software version18. Results: Of the total 100 patients (75 were male with OP poisoning that referred to the Emergency Ward of Razi Hospital, 63 patients presented ECG abnormalities. The mean age of the patients was 35.78 ± 12.91 years. The causes of poisoning were occupational in 71 patients, suicidal in 26 patients, and accidental in 3 patients. Sinus tachycardia (31% was the most common ECG abnormality, followed by non-specific ST-T changes (24%. Overall, mortality rate was 5% and all of the deceased patients presented changes in ECG. Conclusion: OP poisoning is associated with significant ECG abnormalities, especially tachycardia and non-specific ST-T changes.

  16. Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography

    DEFF Research Database (Denmark)

    Vavere, Andrea L; Simon, Gregory G; George, Richard T

    2013-01-01

    Multidetector coronary computed tomography angiography (CTA) is a promising modality for widespread clinical application because of its noninvasive nature and high diagnostic accuracy as found in previous studies using 64 to 320 simultaneous detector rows. It is, however, limited in its ability...... to detect myocardial ischemia. In this article, we describe the design of the CORE320 study ("Combined coronary atherosclerosis and myocardial perfusion evaluation using 320 detector row computed tomography"). This prospective, multicenter, multinational study is unique in that it is designed to assess...... the diagnostic performance of combined 320-row CTA and myocardial CT perfusion imaging (CTP) in comparison with the combination of invasive coronary angiography and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI). The trial is being performed at 16 medical centers located in 8...

  17. In-situ Non-Invasive Imaging of Liquid-Immersed Thin Film Composite Membranes

    KAUST Repository

    Ogieglo, Wojciech

    2017-10-14

    We present a non-invasive method to directly image liquid-immersed thin film composite membranes. The approach allows accessing information not only on the lateral distribution of the coating thickness, including variations in its swelling and density, but also on the distribution of substrate porosity, roughness, accessibility of pores to liquid, and even the degree of pore intrusion related to the thin layer deposition process. The method can be particularly helpful in the fields of functional coatings or membranes to allow laterally-resolved studies under realistic application conditions thereby opening completely new research avenues. The approach is demonstrated in a study of two polymers of intrinsic microporosity, PIM-1 and PIM-6FDA-OH, coated on polyacrylonitrile support and immersed in water. Variations of the skin morphology using different coating methods (floating, spin-coating and dip-coating) are evaluated with the help of the presented method. Surfaces of at least tens of cm2 can be potentially analyzed.

  18. Electrocardiographic artefacts mimicking atrial tachycardia resulted in unnecessary diagnostic and therapeutic measures

    OpenAIRE

    Y-Hassan, Shams; Sylv?n, Christer

    2013-01-01

    Electrocardiographic (ECG) artefacts may closely simulate both supraventricular and ventricular tachycardias. We describe a case initially diagnosed as rapid atrial fibrillation, based on 12-lead surface ECG (especially the limb leads) and monitor tracing. The arrhythmia was resistant to beta blockers. Because of the at times apparently regular rhythm, an esophageal ECG recording was performed, and adenosine was administered. When the presumed atrial fibrillation terminated after sodium pento...

  19. A Preclinical Evaluation of Antrodia camphorata Alcohol Extracts in the Treatment of Non-Small Cell Lung Cancer Using Non-Invasive Molecular Imaging

    Directory of Open Access Journals (Sweden)

    Jeng-Feng Chiou

    2011-01-01

    Full Text Available This study was carried out to provide a platform for the pre-clinical evaluation of anti-cancer properties of a unique CAM (complementary and alternative medicine agent, Antrodia camphorata alcohol extract (ACAE, in a mouse model with the advantageous non-invasive in vivo bioluminescence molecular imaging technology. In vitro analyses on the proliferation, migration/invasion, cell cycle and apoptosis were performed on ACAE-treated non-small cell lung cancer cells, H441GL and control CGL1 cells. In vivo, immune-deficient mice were inoculated subcutaneously with H441GL followed by oral gavages of ACAE. The effect of ACAE on tumor progression was monitored by non-invasive bioluminescence imaging. The proliferation and migration/invasion of H441GL cells were inhibited by ACAE in a dose-dependent manner. In addition, ACAE induced cell cycle arrest at G0/G1 phase and apoptosis in H441GL cells as shown by flow cytometric analysis, Annexin-V immunoflourescence and DNA fragmentation. In vivo bioluminescence imaging revealed that tumorigenesis was significantly retarded by oral treatment of ACAE in a dose-dependent fashion. Based on our experimental data, ACAE contains anti-cancer properties and could be considered as a potential CAM agent in future clinical evaluation.

  20. Evaluation and Immunohistochemical Qualification of Carbogen-Induced ΔR{sub 2}* as a Noninvasive Imaging Biomarker of Improved Tumor Oxygenation

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Lauren C.J., E-mail: lauren.baker@icr.ac.uk [Cancer Research UK and EPSRC Cancer Imaging Centre, Division of Radiotherapy and Imaging, The Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Surrey (United Kingdom); Boult, Jessica K.R.; Jamin, Yann; Gilmour, Lesley D.; Walker-Samuel, Simon; Burrell, Jake S. [Cancer Research UK and EPSRC Cancer Imaging Centre, Division of Radiotherapy and Imaging, The Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Surrey (United Kingdom); Ashcroft, Margaret [Division of Medicine, Centre for Cell Signalling and Molecular Genetics, University College London, London (United Kingdom); Howe, Franklyn A. [St. George' s, University of London, London (United Kingdom); Griffiths, John R. [Cancer Research UK Cambridge Institute, Cambridge (United Kingdom); Raleigh, James A. [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States); Kogel, Albert J. van der [University of Nijmegen Medical Centre, Nijmegen (Netherlands); Robinson, Simon P. [Cancer Research UK and EPSRC Cancer Imaging Centre, Division of Radiotherapy and Imaging, The Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Surrey (United Kingdom)

    2013-09-01

    Purpose: To evaluate and histologically qualify carbogen-induced ΔR{sub 2}* as a noninvasive magnetic resonance imaging biomarker of improved tumor oxygenation using a double 2-nitroimidazole hypoxia marker approach. Methods and Materials: Multigradient echo images were acquired from mice bearing GH3 prolactinomas, preadministered with the hypoxia marker CCI-103F, to quantify tumor R{sub 2}* during air breathing. With the mouse remaining positioned within the magnet bore, the gas supply was switched to carbogen (95% O{sub 2}, 5% CO{sub 2}), during which a second hypoxia marker, pimonidazole, was administered via an intraperitoneal line, and an additional set of identical multigradient echo images acquired to quantify any changes in tumor R{sub 2}*. Hypoxic fraction was quantified histologically using immunofluorescence detection of CCI-103F and pimonidazole adduct formation from the same whole tumor section. Carbogen-induced changes in tumor pO{sub 2} were further validated using the Oxylite fiberoptic probe. Results: Carbogen challenge significantly reduced mean tumor R{sub 2}* from 116 ± 13 s{sup −1} to 97 ± 9 s{sup −1} (P<.05). This was associated with a significantly lower pimonidazole adduct area (2.3 ± 1%), compared with CCI-103F (6.3 ± 2%) (P<.05). A significant correlation was observed between ΔR{sub 2}* and Δhypoxic fraction (r=0.55, P<.01). Mean tumor pO{sub 2} during carbogen breathing significantly increased from 6.3 ± 2.2 mm Hg to 36.0 ± 7.5 mm Hg (P<.01). Conclusions: The combined use of intrinsic susceptibility magnetic resonance imaging with a double hypoxia marker approach corroborates carbogen-induced ΔR{sub 2}* as a noninvasive imaging biomarker of increased tumor oxygenation.

  1. Selective isolation and noninvasive analysis of circulating cancer stem cells through Raman imaging.

    Science.gov (United States)

    Cho, Hyeon-Yeol; Hossain, Md Khaled; Lee, Jin-Ho; Han, Jiyou; Lee, Hun Joo; Kim, Kyeong-Jun; Kim, Jong-Hoon; Lee, Ki-Bum; Choi, Jeong-Woo

    2018-04-15

    Circulating cancer stem cells (CCSCs), a rare circulating tumor cell (CTC) type, recently arose as a useful resource for monitoring and characterizing both cancers and their metastatic derivatives. However, due to the scarcity of CCSCs among hematologic cells in the blood and the complexity of the phenotype confirmation process, CCSC research can be extremely challenging. Hence, we report a nanoparticle-mediated Raman imaging method for CCSC characterization which profiles CCSCs based on their surface marker expression phenotypes. We have developed an integrated combinatorial Raman-Active Nanoprobe (RAN) system combined with a microfluidic chip to successfully process complete blood samples. CCSCs and CTCs were detected (90% efficiency) and classified in accordance with their respective surface marker expression via completely distinct Raman signals of RANs. Selectively isolated CCSCs (93% accuracy) were employed for both in vitro and in vivo tumor phenotyping to identify the tumorigenicity of the CCSCs. We utilized our new method to predict metastasis by screening blood samples from xenograft models, showing that upon CCSC detection, all subjects exhibited liver metastasis. Having highly efficient detection and noninvasive isolation capabilities, we have demonstrated that our RAN-based Raman imaging method will be valuable for predicting cancer metastasis and relapse via CCSC detection. Moreover, the exclusion of peak overlapping in CCSC analysis with our Raman imaging method will allow to expand the RAN families for various cancer types, therefore, increasing therapeutic efficacy by providing detailed molecular features of tumor subtypes. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. The Role of Noninvasive Techniques in Stroke Therapy

    Directory of Open Access Journals (Sweden)

    Daniel Maxwell Bernad

    2008-01-01

    Full Text Available Noninvasive techniques such as functional magnetic resonance imaging (fMRI and transcranial magnetic stimulation (TMS have provided insight into understanding how neural connections are altered in consequence to cerebrovascular injury. The first part of this review will briefly survey some of the methodological issues and limitations related to noninvasive poststroke motor recovery studies. The second section will investigate some of the different neural mechanisms that underlie neurorehabilitation in stroke patients. The third part will explore our current understanding of motor memory processing, describe the neural structures that subserve motor memory consolidation, and discuss the current literature related to memory reconsolidation in healthy adults. Lastly, this paper will suggest the potential therapeutic applications of integrating noninvasive tools with memory consolidation and reconsolidation theories to enhance motor recovery. The overall objective of this work is to demonstrate how noninvasive technologies have been utilized in the multidisciplinary field of clinical behavioral neuroscience and to highlight their potential to be employed as clinical tools to promote individualized motor recovery in stroke patients.

  3. Spinal imaging and image analysis

    CERN Document Server

    Yao, Jianhua

    2015-01-01

    This book is instrumental to building a bridge between scientists and clinicians in the field of spine imaging by introducing state-of-the-art computational methods in the context of clinical applications.  Spine imaging via computed tomography, magnetic resonance imaging, and other radiologic imaging modalities, is essential for noninvasively visualizing and assessing spinal pathology. Computational methods support and enhance the physician’s ability to utilize these imaging techniques for diagnosis, non-invasive treatment, and intervention in clinical practice. Chapters cover a broad range of topics encompassing radiological imaging modalities, clinical imaging applications for common spine diseases, image processing, computer-aided diagnosis, quantitative analysis, data reconstruction and visualization, statistical modeling, image-guided spine intervention, and robotic surgery. This volume serves a broad audience as  contributions were written by both clinicians and researchers, which reflects the inte...

  4. Non-invasive diagnostic method using the phase image for the Kent fiber position in Wolff-Parkinson-White (WPW) syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, Tokuji; Makino, Katsutoshi; Ichikawa, Takehiko; Futagami, Yasuo; Hamada, Masayuki (Mie Univ., Tsu (Japan). School of Medicine)

    1983-10-01

    Gated blood pool scintigraphy with sup(99m)Tc-RBC was performed in patients with WPW syndrome and healthy controls. The contraction of the normal ventricle and the Kent fiber position in cases of WPW syndrome were observed on the phase image obtained by Fourier-transformation of the time activity curve. This method is considered to be more valuable than the other non-invasive procedures in cases of WPW syndrome, especially in the preoperative examination for transecting Kent fibers.

  5. Non-invasive diagnosis in cerebral ischemia by means of magnetic resonance imaging and near-infrared spectroscopy

    International Nuclear Information System (INIS)

    Piepgras, A.; Gueckel, F.; Laemmler, B.; Weigel, R.; Schmiedek, P.

    1994-01-01

    We describe the non-invasive assessment of cerebrovascular reserve capacity by means of near-infrared spectroscopy (NIRS) and magnetic resonance imaging. Both methods are compared with transcranial Doppler sonography. There is a good correlation of the three methods in the changes in cerebral oxygen saturation and in blood velocity following acetazolamide stimulation of cerebral blood flow, except found in one patient with unilateral carotid artery occlusion. In this patient we found a decreased cerebrovascular reserve capacity, revealed by a magnetic resonance technique designed to quantify CBV and CBF. We postulate a raised oxygen extraction as raised oxygen extraction as the cause of his changes in oxygen saturation. (orig.) [de

  6. Portable electrocardiograph through android application.

    Science.gov (United States)

    De Oliveira, Igor H; Cene, V H; Balbinot, A

    2015-01-01

    An electrocardiograph was designed and implemented, being capable of obtaining electrical signals from the heart, and sending this data via Bluetooth to a tablet, in which the signals are graphically shown. The user interface is developed as an Android application. Because of the technological progress and the increasing use of full portable systems, such as tablets and cell phones, it is important to understand the functioning and development of an application, which provides a basis for conducting studies using this technology as an interface. The project development includes concepts of electronics and its application to achieve a portable and functional final project, besides using a specific programmable integrated circuit for electrocardiogram, electroencephalogram and electromyogram, the ADS1294. Using a simulator of cardiac signals, 36 different waveforms were recorded, including normal sinus rhythm, arrhythmias and artifacts. Simulations include variations of heart rate from 30 to 190 beats per minute (BPM), with variations in peak amplitude of 1 mV to 2 mV. Tests were performed with a subject at rest and in motion, observing the signals obtained and the damage to their interpretation due to the introduction of muscle movement artifacts in motion situations.

  7. Non-Invasive Assessment of Hepatic Fibrosis by Elastic Measurement of Liver Using Magnetic Resonance Tagging Images

    Directory of Open Access Journals (Sweden)

    Xuejun Zhang

    2018-03-01

    Full Text Available To date, the measurement of the stiffness of liver requires a special vibrational tool that limits its application in many hospitals. In this study, we developed a novel method for automatically assessing the elasticity of the liver without any use of contrast agents or mechanical devices. By calculating the non-rigid deformation of the liver from magnetic resonance (MR tagging images, the stiffness was quantified as the displacement of grids on the liver image during a forced exhalation cycle. Our methods include two major processes: (1 quantification of the non-rigid deformation as the bending energy (BE based on the thin-plate spline method in the spatial domain and (2 calculation of the difference in the power spectrum from the tagging images, by using fast Fourier transform in the frequency domain. By considering 34 cases (17 normal and 17 abnormal liver cases, a remarkable difference between the two groups was found by both methods. The elasticity of the liver was finally analyzed by combining the bending energy and power spectral features obtained through MR tagging images. The result showed that only one abnormal case was misclassified in our dataset, which implied our method for non-invasive assessment of liver fibrosis has the potential to reduce the traditional liver biopsy.

  8. Non-invasive in vivo imaging of arthritis in a collagen-induced murine model with phosphatidylserine-binding near-infrared (NIR) dye

    OpenAIRE

    Chan, Marion M; Gray, Brian D; Pak, Koon Y; Fong, Dunne

    2015-01-01

    Introduction Development of non-invasive molecular imaging techniques that are based on cellular changes in inflammation has been of active interest for arthritis diagnosis. This technology will allow real-time detection of tissue damage and facilitate earlier treatment of the disease, thus representing an improvement over X-rays, which detect bone damage at the advanced stage. Tracing apoptosis, an event occurring in inflammation, has been a strategy used. PSVue 794 is a low-molecular-weight...

  9. Magnetic resonance imaging goes postmortem: noninvasive detection and assessment of myocardial infarction by postmortem MRI

    International Nuclear Information System (INIS)

    Jackowski, Christian; Warntjes, Marcel J.B.; Persson, Anders; Berge, Johan; Baer, Walter

    2011-01-01

    To investigate the performance of postmortem magnetic resonance imaging (pmMRI) in identification and characterization of lethal myocardial infarction in a non-invasive manner on human corpses. Before forensic autopsy, 20 human forensic corpses were examined on a 1.5-T system for the presence of myocardial infarction. Short axis, transversal and longitudinal long axis images (T1-weighted; T2-weighted; PD-weighted) were acquired in situ. In subsequent autopsy, the section technique was adapted to short axis images. Histological investigations were conducted to confirm autopsy and/or radiological diagnoses. Nineteen myocardial lesions were detected and age staged with pmMRI, of which 13 were histologically confirmed (chronic, subacute and acute). Six lesions interpreted as peracute by pmMRI showed no macroscopic or histological finding. Five of the six peracute lesions correlated well to coronary pathology, and one case displayed a severe hypertrophic alteration. pmMRI reliably demonstrates chronic, subacute and acute myocardial infarction in situ. In peracute cases pmMRI may display ischemic lesions undetectable at autopsy and routine histology. pmMRI has the potential to substantiate autopsy and to counteract the loss of reliable information on causes of death due to the recent disappearance of the clinical autopsy. (orig.)

  10. Risk stratification by using non-invasive radionuclide imaging in patients with unstable angina spec tories

    International Nuclear Information System (INIS)

    Saghari, M.

    2002-01-01

    Unstable angina represents a heterogeneous spectrum of clinical entities between chronic stable angina and acute myocardial infraction. Acute ischemic syndromes (including unstable angina) result from abrupt reduction in coronary flow, frequently after atherosclerotic plaque disruption and with or without associated thrombosis or vasospasm. Nuclear cardiology studies and in particular, myocardial perfusion imaging are powerful noninvasive tools for detecting and assessing the severity of acute ischemic syndromes, including unstable angina pec tories. The information derived from a nuclear cardiology study can answer unresolved clinical question and aid in subsequent patient management, specifically jeopardized myocardium detected during spontaneously occurring acute chest pain or controlled stress testing are important determinant of: 1) The need for admission to an intensive care monitoring unit 2) The need for and urgency of coronary angiography 3) The appropriate use of percutaneous or surgical coronary revascularization procedures. Extensive information suggests the stress nuclear perfusion imaging is the best validated technique for predischarge risk stratification with unstable angina patients who have been medically stabilized. Early information suggests avoidance of unecessary coronary angiography or revascularization is the cost effective strategy

  11. A matter of collection and detection for intraoperative and noninvasive near-infrared fluorescence molecular imaging: To see or not to see?

    Science.gov (United States)

    Zhu, Banghe; Rasmussen, John C.; Sevick-Muraca, Eva M.

    2014-01-01

    Purpose: Although fluorescence molecular imaging is rapidly evolving as a new combinational drug/device technology platform for molecularly guided surgery and noninvasive imaging, there remains no performance standards for efficient translation of “first-in-humans” fluorescent imaging agents using these devices. Methods: The authors employed a stable, solid phantom designed to exaggerate the confounding effects of tissue light scattering and to mimic low concentrations (nM–pM) of near-infrared fluorescent dyes expected clinically for molecular imaging in order to evaluate and compare the commonly used charge coupled device (CCD) camera systems employed in preclinical studies and in human investigational studies. Results: The results show that intensified CCD systems offer greater contrast with larger signal-to-noise ratios in comparison to their unintensified CCD systems operated at clinically reasonable, subsecond acquisition times. Conclusions: Camera imaging performance could impact the success of future “first-in-humans” near-infrared fluorescence imaging agent studies. PMID:24506637

  12. Non-invasive diagnostic method using the phase image for the Kent fiber position in Wolff-Parkinson-White (WPW) syndrome

    International Nuclear Information System (INIS)

    Konishi, Tokuji; Makino, Katsutoshi; Ichikawa, Takehiko; Futagami, Yasuo; Hamada, Masayuki

    1983-01-01

    Gated blood pool scintigraphy with sup(99m)Tc-RBC was performed in patients with WPW syndrome and healthy controls. The contraction of the normal ventricle and the Kent fiber position in cases of WPW syndrome were observed on the phase image obtained by Fourier-transformation of the time activity curve. This method is considered to be more valuable than the other non-invasive procedures in cases of WPW syndrome, especially in the preoperative examination for transecting Kent fibers. (Namekawa, K.)

  13. Noninvasive murine glioma detection improved following photobleaching of skin PpIX fluorescence

    Science.gov (United States)

    Gibbs-Strauss, Summer L.; Davis, Scott C.; O'Hara, Julia A.; Hoopes, P. Jack; Hasan, Tayyaba; Pogue, Brian W.

    2008-02-01

    Aminolevulinic Acid (ALA) is a prodrug which can be administered to cells, animals or patients after which it is transformed via the Heme synthesis pathway into the fluorescent molecule Protoporphyrin IX (PpIX). PpIX has been shown to be useful as both a photosensitizer for photodynamic therapy (PDT) and as a fluorescence imaging contrast agent. The ALA-PpIX system not only provides contrast for fluorescence imaging but also gives information about the metabolic activity of the imaged tissue and thus could be useful for monitoring cancer therapy. In the current study skin photobleaching was examined to determine if PpIX fluorescence contrast in malignant brain tumors could be better visualized noninvasively. Red light photobleaching decreased skin PpIX fluorescence and increased the ability to noninvasively quantify PpIX fluorescence in murine gliomas, as in vivo measurements of mean PpIX fluorescence more closely matched ex vivo quantification following skin photobleaching. Three doses of blue light photobleaching (4 J/cm2, 8 J/cm2 and 12 J/cm2) were tested and determined to give similar levels of skin photobleaching as well as a similar window of decreased skin PpIX fluorescence for noninvasive fluorescence imaging following the photobleaching dose administration.

  14. Noninvasive physiologic assessment of coronary stenoses using cardiac CT.

    Science.gov (United States)

    Xu, Lei; Sun, Zhonghua; Fan, Zhanming

    2015-01-01

    Coronary CT angiography (CCTA) has become an important noninvasive imaging modality in the diagnosis of coronary artery disease (CAD). CCTA enables accurate evaluation of coronary artery stenosis. However, CCTA provides limited information on the physiological significance of stenotic lesions. A noninvasive "one-stop-shop" diagnostic test that can provide both anatomical significance and functional significance of stenotic lesions would be beneficial in the diagnosis and management of CAD. Recently, with the introduction of novel techniques, such as myocardial CT perfusion, CT-derived fractional flow reserve (FFRCT), and transluminal attenuation gradient (TAG), CCTA has emerged as a noninvasive method for the assessment of both anatomy of coronary lesions and its physiological consequences during a single study. This review provides an overview of the current status of new CT techniques for the physiologic assessments of CAD.

  15. Partial flip angle spin-echo imaging to obtain T1 weighted images with electrocardiographic gating

    International Nuclear Information System (INIS)

    Kawamitsu, Hideaki; Sugimura, Kazuro; Kasai, Toshifumi; Kimino, Katsuji

    1993-01-01

    ECG-gated spin-echo (SE) imaging can reduce physiologic motion artifact. However, it does not provide strong T 1 -weighted images, because the repetition time (TR) depends on heart rate (HR). For odd-echo SE imaging, T 1 contrast can be maximized by using a smaller flip angle (FA) of initial excitation RF pulses. We investigated the usefulness of partial FA SE imaging in order to obtain more T 1 -dependent contrast with ECG gating and determined the optimal FA at each heart rate. In computer simulation and phantom study, the predicted image contrast and signal-to-noise ratio (SNR) obtained for each FA (0∼180deg) and each HR (55∼90 beats per minute (bpm)) were compared with those obtained with conventional T 1 -weighted SE imaging (TR=500 ms, TE=20 ms, FA=90deg). The optimal FA was decreased by reducing HR. The FA needed to obtain T 1 -dependent contrast identical to that with T 1 -weighted SE imaging was 43deg at a HR of 65 bpm, 53deg at 70 bpm, 60deg at 75 bpm. This predicted FA were in excellent agreement with that obtained with clinical evaluation. The predicted SNR was decreased by reducing FA. The SNR of partial FA SE imaging at HR of 65 bpm (FA=43deg) was 80% of that with conventional T 1 -weighted SE imaging. However, this imaging method presented no marked clinical problem. ECG-gated partial FA SE imaging provides better T 1 -dependent contrast than conventional ECG-gated SE imaging, especially for Gd-DTPA enhanced imaging. (author)

  16. Hormonal, Electrolytic, and Electrocardiographic Evaluations in Bitches With Eutocia and Dystocia.

    Science.gov (United States)

    Simões, Carla Regina Barbieri; Vassalo, Flávia Gardilin; Lourenço, Maria Lúcia Gomes; de Souza, Fabiana Ferreira; Oba, Eunice; Sudano, Mateus José; Prestes, Nereu Carlos

    2016-12-01

    The objective of the study was to assess clinical alterations, electrocardiographic, hematological, biochemical, hemogasometric, electrolytic, and hormone plasma concentrations in bitches with eutocia and dystocia. Overall, 28 bitches (dystocia, n = 22 and eutocia, n = 6) were assessed. The evaluations were performed at 2 time points, M1 (1 hour prepartum-eutocia group and cesarean or clinical intervention-dystocia group) and M2 (postpartum-eutocia or dystocia group and anesthetic recovery-dystocia group). The main clinical finding was the hypothermia (mean: 36.9°C dystocia vs. 36.8°C eutocia). Sinus arrhythmia and tachycardia were the electrocardiographic parameters predominant in eutocia and sinus rhythm in dystocia group. The P wave amplitude, heart rate, creatinine concentration, hematocrit, and hemoglobin were increased in M1 (P dystocia and total T 3 concentrations were increased in M1 in both groups. Total T 4 was higher in dystocia during M1 and in dystocia during M2 in eutocia than in dystocia. We concluded that at 1 hour prepartum or pre-cesarean, there is an increase in heart rate in bitches with eutocia or dystocia, and this finding was correlated to thyroid hormone concentration. P 4 concentrations remained high during dystocia, and hematological and biochemical changes returned to normal after parturition. The evaluation of these parameters in pregnancy can be used as tool to prevent dystocia and consequent fetal death. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Noninvasive determination of myocardial blood flow, oxygen consumption and efficiency in normal humans by carbon-11 acetate positron emission tomography imaging

    International Nuclear Information System (INIS)

    Porenta, G.; Cherry, S.; Czernin, J.; Brunken, R.; Kuhle, W.; Hashimoto, T.; Schelbert, H.R.

    1999-01-01

    The aims of this study were: (1) to measure noninvasively and near simultaneously myocardial blood flow, oxygen consumption, and contractile function and (2) to analyze myocardial energy expenditure and efficiency at rest and during dobutamine stress in normal humans. Dynamic and gated carbon-11 acetate positron emission tomography (PET) imaging was performed in 11 normal subjects. The initial uptake of 11 C-acetate was measured to estimate myocardial blood flow. Oxygen consumption was derived from the monoexponential slope of the 11 C-clearance curve recorded during myocardial washout. ECG-gated systolic and diastolic images were acquired during the peak myocardial 11 C activity to measure left ventricular radius, myocardial wall thickness, and long axis length. Myocardial oxygen consumption and parameters of cardiac geometry were used to determine myocardial energetics and cardiac efficiency by tension-area area analysis. Myocardial blood flow averaged 0.8±0.06 ml min -1 g -1 at rest and 1.48±0.15 ml min -1 g -1 during dobutamine stress. Oxygen delivery and consumption were 151±13 and 88±15 μl O 2 min -1 g -1 at rest and increased to 291±31 and 216±31 μl O 2 min -1 g -1 , respectively, during pharmacological stress (P 11 C acetate imaging provides the unique capability to study noninvasively determinants of myocardial energy delivery, expenditure, and efficiency. (orig.)

  18. Non-Invasive Detection of Lung Inflammation by Near-Infrared Fluorescence Imaging Using Bimodal Liposomes.

    Science.gov (United States)

    Desu, Hari R; Wood, George C; Thoma, Laura A

    2016-01-01

    Acute lung injury (ALI) and its more severe form, acute respiratory distress syndrome results in respiratory obstruction and severe lung inflammation. Critical characteristics of ALI are alveolar edema, infiltration of leukocytes (neutrophils and monocytes), release of pro-inflammatory cytokines and chemokines into broncho-alveolar lavage fluid, and activation of integrin receptors. The purpose of the study was to demonstrate non-invasive detection of lung inflammation using integrin receptor targeted fluorescence liposomes. An inflammation similar to that observed in ALI was elicited in rodents by intra-tracheal instillation of interleukin-1beta (IL-1beta). Cyclic arginine glycine-(D)-aspartic acid-peptide (cRGD-peptide) grafted fluorescence liposomes were administered to ALI induced male Sprague-Dawley rats for targeting lung integrin receptors. Near-infrared fluorescence imaging (NIRFI) was applied for visualization and quantitation of lung inflammation. NIRFI signals were correlated with inflammatory cellular and biochemical markers of lungs. A positive correlation was observed between NIRF signals and lung inflammation markers. Compared to control group, an intense NIRF signal was observed in ALI induced rats in the window 6-24 h post-IL-1beta instillation. Interaction of integrin receptors with targeted liposomes was assumed to contribute to intense NIRF signal. RT-PCR studies showed an elevated lung expression of alphavbeta5 integrin receptors, 12 h post-IL-1beta instillation. In vitro studies demonstrated integrin receptor specificity of targeted liposomes. These targeted liposomes showed binding to alphavbeta5 integrin receptors expressed on alveolar cells. Non-invasive detection of lung inflammation was demonstrated using a combination of integrin receptor targeting and NIRFI.

  19. Are novel non-invasive imaging techniques needed in patients with suspected prosthetic heart valve endocarditis? A systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Habets, Jesse; Mali, Willem P.T.M. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Tanis, Wilco [Haga Teaching Hospital, Department of Cardiology, The Hague (Netherlands); Reitsma, Johannes B. [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); Brink, Renee B.A. van den [Academic Medical Center, Department of Cardiology, Amsterdam (Netherlands); Chamuleau, Steven A.J. [University Medical Center Utrecht, Department of Cardiology, Utrecht (Netherlands); Budde, Ricardo P.J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands)

    2015-07-15

    Multimodal non-invasive imaging plays a key role in establishing a diagnosis of PHV endocarditis. The objective of this study was to provide a systematic review of the literature and meta-analysis of the diagnostic accuracy of TTE, TEE, and MDCT in patients with (suspected) PHV endocarditis. Studies published between 1985 and 2013 were identified via search and cross-reference of PubMed/Embase databases. Studies were included if (1) they reported on the non-invasive index tests TTE, TEE, or MDCT; (2) data was provided on PHV endocarditis as the condition of interest; and (3) imaging results were verified against either surgical inspection/autopsy or clinical follow-up reference standards, thereby enabling the extraction of 2-by-2 tables. Twenty articles (including 496 patients) met the inclusion criteria for PHV endocarditis. TTE, TEE, and MDCT + TEE had a pooled sensitivity/specificity for vegetations of 29/100 %; 82/95 %, and 88/94 %, respectively. The pooled sensitivity/specificity of TTE, TEE, and MDCT + TEE for periannular complications was 36/93 %, 86/98 %, and 100/94 %, respectively. TEE showed good sensitivity and specificity for establishing a diagnosis of PHV endocarditis. Although MDCT data are limited, this review showed that MDCT in addition to TEE may improve sensitivity in detecting life-threatening periannular complications. (orig.)

  20. Are novel non-invasive imaging techniques needed in patients with suspected prosthetic heart valve endocarditis? A systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Habets, Jesse; Mali, Willem P.T.M.; Tanis, Wilco; Reitsma, Johannes B.; Brink, Renee B.A. van den; Chamuleau, Steven A.J.; Budde, Ricardo P.J.

    2015-01-01

    Multimodal non-invasive imaging plays a key role in establishing a diagnosis of PHV endocarditis. The objective of this study was to provide a systematic review of the literature and meta-analysis of the diagnostic accuracy of TTE, TEE, and MDCT in patients with (suspected) PHV endocarditis. Studies published between 1985 and 2013 were identified via search and cross-reference of PubMed/Embase databases. Studies were included if (1) they reported on the non-invasive index tests TTE, TEE, or MDCT; (2) data was provided on PHV endocarditis as the condition of interest; and (3) imaging results were verified against either surgical inspection/autopsy or clinical follow-up reference standards, thereby enabling the extraction of 2-by-2 tables. Twenty articles (including 496 patients) met the inclusion criteria for PHV endocarditis. TTE, TEE, and MDCT + TEE had a pooled sensitivity/specificity for vegetations of 29/100 %; 82/95 %, and 88/94 %, respectively. The pooled sensitivity/specificity of TTE, TEE, and MDCT + TEE for periannular complications was 36/93 %, 86/98 %, and 100/94 %, respectively. TEE showed good sensitivity and specificity for establishing a diagnosis of PHV endocarditis. Although MDCT data are limited, this review showed that MDCT in addition to TEE may improve sensitivity in detecting life-threatening periannular complications. (orig.)

  1. Biphasic thallium 201 SPECT-imaging for the noninvasive diagnosis of myocardial perfusion abnormalities in a child with Kawasaki disease--a case report

    International Nuclear Information System (INIS)

    Hausdorf, G.; Nienaber, C.A.; Spielman, R.P.

    1988-01-01

    The mucocutaneous lymph node syndrome (Kawasaki disease) is of increasing importance for the pediatric cardiologist, for coronary aneurysms with the potential of thrombosis and subsequent stenosis can develop in the course of the disease. The authors report a 2 1/2-year-old female child in whom, fourteen months after the acute phase of Kawasaki disease, myocardial infarction occurred. Biphasic thallium 201 SPECT-imaging using dipyridamole depicted anterior wall ischemia and inferolateral infarction. This case demonstrates that noninvasive vasodilation-redistribution thallium 201 SPECT-imaging has the potential to predict reversible myocardial perfusion defects and myocardial necrosis, even in small infants with Kawasaki disease

  2. Electrocardiographic markers of ischemia during mental stress testing in postinfarction patients. Role of body surface mapping

    International Nuclear Information System (INIS)

    Bosimini, E.; Galli, M.; Guagliumi, G.; Giubbini, R.; Tavazzi, L.

    1991-01-01

    In patients with coronary artery disease, radionuclide investigations have documented a high incidence of mental stress-induced myocardial ischemia in the absence of significant electrocardiographic changes and/or angina. To investigate the causes of the low electrocardiographic sensitivity, we recorded body surface maps during mental arithmetic in 22 normal volunteers and 37 postinfarction patients with residual exercise ischemia. Myocardial perfusion was studied with thallium-201 or technetium-99 (SESTAMIBI) planar scans. In 14 patients, body surface maps were also recorded during atrial pacing at the heart rate values achieved during mental stress. While taking the body surface maps, the area from J point to 80 msec after this point (ST-80) was analyzed by integral maps, difference maps, and departure maps. The body surface mapping criteria for ischemia were a new negative area on the integral maps, a negative potential of more than 2 SD from mean normal values on the difference maps, and a negative departure index of more than 2. Scintigraphy showed asymptomatic myocardial hypoperfusion in 33 patients. Eight patients had significant ST segment depression. The ST-80 integral and difference maps identified 17 ischemic patients. Twenty-four patients presented abnormal departure maps. One patient presented ST depression and abnormal body surface maps without reversible tracer defect. In 14 of 14 patients, atrial pacing did not reproduce the body surface map abnormalities. The analyses of the other electrocardiographic variables showed that in patients with mental stress-induced perfusion defects, only changes of T apex-T offset (aT-eT) interval in Frank leads and changes of maximum negative potential value of aT-eT integral maps significantly differed from those of normal subjects

  3. Comparing the Validity of Non-Invasive Methods in Measuring Thoracic Kyphosis and Lumbar Lordosis

    Directory of Open Access Journals (Sweden)

    Mohammad Yousefi

    2012-04-01

    Full Text Available Background: the purpose of this article is to study the validity of each of the non-invasive methods (flexible ruler, spinal mouse, and processing the image versus the one through-Ray radiation (the basic method and comparing them with each other.Materials and Methods: for evaluating the validity of each of these non-invasive methods, the thoracic Kyphosis and lumber Lordosis angle of 20 students of Birjand University (age mean and standard deviation: 26±2, weight: 72±2.5 kg, height: 169±5.5 cm through fours methods of flexible ruler, spinal mouse, and image processing and X-ray.Results: the results indicated that the validity of the methods including flexible ruler, spinal mouse, and image processing in measuring the thoracic Kyphosis and lumber Lordosis angle respectively have an adherence of 0.81, 0.87, 0.73, 0.76, 0.83, 0.89 (p>0.05. As a result, regarding the gained validity against the golden method of X-ray, it could be stated that the three mentioned non-invasive methods have adequate validity. In addition, the one-way analysis of variance test indicated that there existed a meaningful relationship between the three methods of measuring the thoracic Kyphosis and lumber Lordosis, and with respect to the Tukey’s test result, the image processing method is the most precise one.Conclusion as a result, this method could be used along with other non-invasive methods as a valid measuring method.

  4. Noninvasive Physiologic Assessment of Coronary Stenoses Using Cardiac CT

    Directory of Open Access Journals (Sweden)

    Lei Xu

    2015-01-01

    Full Text Available Coronary CT angiography (CCTA has become an important noninvasive imaging modality in the diagnosis of coronary artery disease (CAD. CCTA enables accurate evaluation of coronary artery stenosis. However, CCTA provides limited information on the physiological significance of stenotic lesions. A noninvasive “one-stop-shop” diagnostic test that can provide both anatomical significance and functional significance of stenotic lesions would be beneficial in the diagnosis and management of CAD. Recently, with the introduction of novel techniques, such as myocardial CT perfusion, CT-derived fractional flow reserve (FFRCT, and transluminal attenuation gradient (TAG, CCTA has emerged as a noninvasive method for the assessment of both anatomy of coronary lesions and its physiological consequences during a single study. This review provides an overview of the current status of new CT techniques for the physiologic assessments of CAD.

  5. The relationship of cardiovascular risk factors and electrocardiographic findings: Isfahan Healthy Heart Program

    OpenAIRE

    Nizal Sarrafzadegan; Masoumeh Sadeghi; Forough Khademi; Mohammad Arash Ramezani; Mohammad Hashemi Jazi

    2012-01-01

       BACKGROUND: Cardiovascular disease (CVD) is the leading cause of mortality worldwide. Various studies showed relationship between electrocardiographic (ECG) changes at rest and CVD mortality. Present study was performed to find the relation between ECG and CVD risk factors in an Iranian population.    METHODS: This cross-sectional study was performed on 3343 subjects aged ≥ 35 years from three provincial cities of Isfahan, Arak, and Najafabad. Demographic and lifesty...

  6. Chronic valvular disease: correlation between clinical, electrocardiographic, radiographic and echocardiographic aspects in dogs

    International Nuclear Information System (INIS)

    Soares, E.C.; Larsson, M.H.M.A.; Yamato, R.J.

    2005-01-01

    Echocardiographic aspects of chronic mitral valvular disease were studied and compared to physical, radiographic and electrocardiographic aspects. Seventy dogs were used, and clinical examination, thoracic radiography, electrocardiogram and echocardiogram were performed. Correlations between regurgitation severity with cardiac failure functional class and murmur intensity were observed. The electrocardiogram showed a low sensibility in detecting cardiac chamber enlargement, caused by mitral regurgitation. All the dogs with severe mitral regurgitation showed cardiomegaly according to thoracic radiographies

  7. Development of magnetic resonance technology for noninvasive boron quantification

    International Nuclear Information System (INIS)

    Bradshaw, K.M.

    1990-11-01

    Boron magnetic resonance imaging (MRI) and spectroscopy (MRS) were developed in support of the noninvasive boron quantification task of the Idaho National Engineering Laboratory (INEL) Power Burst Facility/Boron Neutron Capture Therapy (PBF/BNCT) program. The hardware and software described in this report are modifications specific to a GE Signa trademark MRI system, release 3.X and are necessary for boron magnetic resonance operation. The technology developed in this task has been applied to obtaining animal pharmacokinetic data of boron compounds (drug time response) and the in-vivo localization of boron in animal tissue noninvasively. 9 refs., 21 figs

  8. Image Quality, Overall Evaluability, and Effective Radiation Dose of Coronary Computed Tomography Angiography With Prospective Electrocardiographic Triggering Plus Intracycle Motion Correction Algorithm in Patients With a Heart Rate Over 65 Beats Per Minute.

    Science.gov (United States)

    Pontone, Gianluca; Muscogiuri, Giuseppe; Baggiano, Andrea; Andreini, Daniele; Guaricci, Andrea I; Guglielmo, Marco; Fazzari, Fabio; Mushtaq, Saima; Conte, Edoardo; Annoni, Andrea; Formenti, Alberto; Mancini, Elisabetta; Verdecchia, Massimo; Fusini, Laura; Bonfanti, Lorenzo; Consiglio, Elisa; Rabbat, Mark G; Bartorelli, Antonio L; Pepi, Mauro

    2018-01-16

    Recently, a new intracycle motion correction algorithm (MCA) was introduced to reduce motion artifacts from heart rate (HR) in coronary computed tomography angiography (cCTA). The aim of the study was to evaluate the image quality, overall evaluability, and effective radiation dose (ED) of cCTA with prospective electrocardiographic (ECG) triggering plus MCA as compared with standard protocol with retrospective ECG triggering in patients with HR≥65 bpm. One hundred consecutive patients (67±10 y) scheduled for cCTA with 65Ethics Committee and a written informed consent was obtained from all patients. Image noise, signal to noise ratio, contrast to noise ratio, Likert image quality score (score 1, nondiagnostic; score 2, adequate; score 3, good; score 4, excellent), overall image evaluability, and ED were measured and compared between the 2 groups. Both vessel-based and patient-based analyses were evaluated. Student test or Wilcoxon test were used to evaluate differences of continuous variables, whereas the χ test was used to study differences with regard to categorical data. A P-value <0.05 was considered statistically significant. cCTA was successfully performed in all patients. In a segment-based model, group 1 compared with group 2 showed a lower rate of overall artifacts (67% vs. 83%; P<0.001) and motion artifacts (49% vs. 66%; P<0.001), resulting in a better Likert image quality score (2.83±1.03 vs. 2.37±1.02; P<0.01) and overall evaluability (85% vs. 75%; P<0.01). Group 1 showed a lower ED as compared with group 2 (3.1±1.9 vs. 11.9±3.3 mSv; P<0.01). MCA and cCTA with prospective ECG-triggering acquisition in patients with high HR improves image quality and overall evaluability compared with cCTA with standard retrospective ECG triggering.

  9. Non-invasive airway health assessment: Synchrotron imaging reveals effects of rehydrating treatments on mucociliary transit in-vivo

    Science.gov (United States)

    Donnelley, Martin; Morgan, Kaye S.; Siu, Karen K. W.; Farrow, Nigel R.; Stahr, Charlene S.; Boucher, Richard C.; Fouras, Andreas; Parsons, David W.

    2014-01-01

    To determine the efficacy of potential cystic fibrosis (CF) therapies we have developed a novel mucociliary transit (MCT) measurement that uses synchrotron phase contrast X-ray imaging (PCXI) to non-invasively measure the transit rate of individual micron-sized particles deposited into the airways of live mice. The aim of this study was to image changes in MCT produced by a rehydrating treatment based on hypertonic saline (HS), a current CF clinical treatment. Live mice received HS containing a long acting epithelial sodium channel blocker (P308); isotonic saline; or no treatment, using a nebuliser integrated within a small-animal ventilator circuit. Marker particle motion was tracked for 20 minutes using PCXI. There were statistically significant increases in MCT in the isotonic and HS-P308 groups. The ability to quantify in vivo changes in MCT may have utility in pre-clinical research studies designed to bring new genetic and pharmaceutical treatments for respiratory diseases into clinical trials.

  10. Cardiac memory in patients with Wolff-Parkinson-White syndrome: noninvasive imaging of activation and repolarization before and after catheter ablation.

    Science.gov (United States)

    Ghosh, Subham; Rhee, Edward K; Avari, Jennifer N; Woodard, Pamela K; Rudy, Yoram

    2008-08-26

    Cardiac memory refers to a change in ventricular repolarization induced by and persisting for minutes to months after cessation of a period of altered ventricular activation (eg, resulting from pacing or preexcitation in patients with Wolff-Parkinson-White syndrome). ECG imaging (ECGI) is a novel imaging modality for noninvasive electroanatomic mapping of epicardial activation and repolarization. Fourteen pediatric patients with Wolff-Parkinson-White syndrome and no other congenital disease, were imaged with ECGI a day before and 45 minutes, 1 week, and 1 month after successful catheter ablation. ECGI determined that preexcitation sites were consistent with sites of successful ablation in all cases to within a 1-hour arc of each atrioventricular annulus. In the preexcited rhythm, activation-recovery interval (ARI) was the longest (349+/-6 ms) in the area of preexcitation leading to high average base-to-apex ARI dispersion of 95+/-9 ms (normal is approximately 40 ms). The ARI dispersion remained the same 45 minutes after ablation, although the activation sequence was restored to normal. ARI dispersion was still high (79+/-9 ms) 1 week later and returned to normal (45+/-6 ms) 1 month after ablation. The study demonstrates that ECGI can noninvasively localize ventricular insertion sites of accessory pathways to guide ablation and evaluate its outcome in pediatric patients with Wolff-Parkinson-White syndrome. Wolff-Parkinson-White is associated with high ARI dispersion in the preexcited rhythm that persists after ablation and gradually returns to normal over a period of 1 month, demonstrating the presence of cardiac memory. The 1-month time course is consistent with transcriptional reprogramming and remodeling of ion channels.

  11. Noninvasive photoacoustic measurement of absorption coefficient using internal light irradiation of cylindrical diffusing fiber

    Science.gov (United States)

    Peng, Dong-qing; Zhu, Li-li; Li, Zhi-fang; Li, Hui

    2017-09-01

    Absorption coefficient of biological tissue is an important parameter in biomedicine, but its determination remains a challenge. In this paper, we propose a method using focusing photoacoustic imaging technique and internal light irradiation of cylindrical diffusing fiber (CDF) to quantify the target optical absorption coefficient. Absorption coefficients for ink absorbers are firstly determined through photoacoustic and spectrophotometric measurements at the same excitation, which demonstrates the feasibility of this method. Also, the optical absorption coefficients of ink absorbers with several concentrations are measured. Finally, the two-dimensional scanning photoacoustic image is obtained. Optical absorption coefficient measurement and simultaneous photoacoustic imaging of absorber non-invasively are the typical characteristics of the method. This method can play a significant role for non-invasive determination of blood oxygen saturation, the absorption-based imaging and therapy.

  12. Causes of ischemic electrocardiographic changes in near drowning: A literature review.

    Science.gov (United States)

    Omar, Hesham R; Sprenker, Collin; Bosco, Gerardo; Mangar, Devanand; Camporesi, Enrico M

    2015-10-01

    Drowning is a main cause of accidental death among children and adolescents worldwide. Ischemic electrocardiographic (ECG) changes are often encountered in victims of near drowning. We reviewed the literature for near drowning cases reporting ischemic ECG changes to study the underlying etiology for these findings. Among the 8 cases included in the analysis, ischemic ECG changes were due to takotsubo cardiomyopathy (in elderly cases especially females); coronary artery spasm (in younger cases); or hypothermia effect on ECG; and, to a lesser extent, myocardial ischemia resulting from occlusive coronary artery disease. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Noninvasive monitoring of placenta-specific transgene expression by bioluminescence imaging.

    Directory of Open Access Journals (Sweden)

    Xiujun Fan

    Full Text Available BACKGROUND: Placental dysfunction underlies numerous complications of pregnancy. A major obstacle to understanding the roles of potential mediators of placental pathology has been the absence of suitable methods for tissue-specific gene manipulation and sensitive assays for studying gene functions in the placentas of intact animals. We describe a sensitive and noninvasive method of repetitively tracking placenta-specific gene expression throughout pregnancy using lentivirus-mediated transduction of optical reporter genes in mouse blastocysts. METHODOLOGY/PRINCIPAL FINDINGS: Zona-free blastocysts were incubated with lentivirus expressing firefly luciferase (Fluc and Tomato fluorescent fusion protein for trophectoderm-specific infection and transplanted into day 3 pseudopregnant recipients (GD3. Animals were examined for Fluc expression by live bioluminescence imaging (BLI at different points during pregnancy, and the placentas were examined for tomato expression in different cell types on GD18. In another set of experiments, blastocysts with maximum photon fluxes in the range of 2.0E+4 to 6.0E+4 p/s/cm(2/sr were transferred. Fluc expression was detectable in all surrogate dams by day 5 of pregnancy by live imaging, and the signal increased dramatically thereafter each day until GD12, reaching a peak at GD16 and maintaining that level through GD18. All of the placentas, but none of the fetuses, analyzed on GD18 by BLI showed different degrees of Fluc expression. However, only placentas of dams transferred with selected blastocysts showed uniform photon distribution with no significant variability of photon intensity among placentas of the same litter. Tomato expression in the placentas was limited to only trophoblast cell lineages. CONCLUSIONS/SIGNIFICANCE: These results, for the first time, demonstrate the feasibility of selecting lentivirally-transduced blastocysts for uniform gene expression in all placentas of the same litter and early

  14. Non-invasive dendrochronology of late-medieval objects in Oslo

    DEFF Research Database (Denmark)

    Daly, Aoife; Streeton, Noëlle L.W.

    2017-01-01

    scanner. For these reasons, a combined approach was adopted, utilizing CT scanning where possible, but preceded by an ‘exposed-wood’ imaging technique. Both non-invasive techniques have yielded reliable results, and CT scanning has confirmed the reliability of the imaging technique alone. This paper...... presents the analytical methods, along with results from two of the 13 objects under investigation. Results for reliable dates and provenances provide new foundations for historical interpretations....

  15. Screening of young competitive athletes for the prevention of sudden cardiac death with a wireless electrocardiographic transmission device: a pilot study.

    Science.gov (United States)

    Cho, Jae Hyung; Selen, Mats A; Kocheril, Abraham G

    2015-08-11

    The 12-lead electrocardiographic screening for the prevention of sudden cardiac death in young competitive athletes is not cost-effective and thus not routinely recommended. We investigate whether a less expensive wireless electrocardiographic transmission device can be used to screen for the prevention of sudden cardiac death in this population. During pre-participation screening, twenty college football players underwent two electrocardiograms: a conventional 12-lead electrocardiogram and a wireless 9-lead electrocardiogram. We compared several electrocardiographic parameters (QRS duration, left ventricular hypertrophy using the Cornell voltage criteria and the Sokolow-Lyon criteria, ST deviation and corrected QT interval) to determine the correlation. The QRS duration, left ventricular hypertrophy using the Cornell voltage criteria and the Sokolow-Lyon criteria and corrected QT interval exhibited significant correlation between the two types of electrocardiograms (correlation coefficient 0.878, 0.630, 0.770 and 0.847, respectively with P values of 0.01, 0.003, 0.01 and 0.01, respectively). ST deviation in V1 was weakly correlated between the two types of electrocardiograms without statistical significance (correlation coefficient 0.360 with a P value of 0.119). Our newly developed wireless 9-lead electrocardiogram demonstrated significant correlations with a conventional 12-lead electrocardiogram in terms of QRS duration, left ventricular hypertrophy and corrected QT interval.

  16. Classified study and clinical value of the phase imaging features

    International Nuclear Information System (INIS)

    Dang Yaping; Ma Aiqun; Zheng Xiaopu; Yang Aimin; Xiao Jiang; Gao Xinyao

    2000-01-01

    445 patients with various heart diseases were examined by the gated cardiac blood pool imaging, and the phase was classified. The relationship between the seven types with left ventricular function index, clinical heart function, different heart diseases as well as electrocardiograph was studied. The results showed that the phase image classification could match with the clinical heart function. It can visually, directly and accurately indicate clinical heart function and can be used to identify diagnosis of heart disease

  17. Takotsubo Cardiomyopathy in Intensive Care Unit: Prevention, Diagnosis and Management

    Directory of Open Access Journals (Sweden)

    Hannah Masoud

    2016-01-01

    Full Text Available Accurate diagnosis of Takotsubo Cardiomyopathy has substantial prognostic implications in an intensive care unit, given its increased mortality risk and association with life-threatening complications. This report seeks to discuss diagnostic modalities that can be useful in accurately differentiating Takotsubo Cardiomyopathy from Acute Coronary Syndrome, and also briefly discuss prevention and management of this cardiomyopathy in an intensive care unit. For critically ill Takotsubo patients, intensive clinicians can consider establishment of diagnosis by specific electrocardiograph changes, distinctive marked release of cardiac enzymes, characteristic echocardiograph findings, as well as invasive coronary angiography or noninvasive cardiac magnetic imaging.

  18. Non-invasive assessment of vessel morphology and function in tumors by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kiessling, Fabian; Jugold, Manfred; Woenne, Eva C.; Brix, Gunnar

    2007-01-01

    The switch to an angiogenic phenotype is an important precondition for tumor growth, invasion and spread. Since newly formed vessels are characterized by structural, functional and molecular abnormalities, they offer promising targets for tumor diagnosis and therapy. Previous studies indicate that MRI is valuable to assess vessel morphology and function. It can be used to distinguish between benign and malignant lesions and to improve delineation of proliferating areas within heterogeneous tumors. In addition, tracer kinetic analysis of contrast-enhanced image series allows the estimation of well-defined physiological parameters such as blood volume, blood flow and vessel permeability. Frequently, changes of these parameters during cytostatic, anti-angiogenic and radiation therapy precede tumor volume reduction. Moreover, target-specific MRI techniques can be used to elucidate the expression of angiogenic markers at the molecular level. This review summarizes strategies for non-invasive characterization of tumor vascularization by functional and molecular MRI, hereby introducing representative preclinical and clinical applications. (orig.)

  19. Electrocardiographic evaluation of two anesthetic combinations in dogs

    Directory of Open Access Journals (Sweden)

    Tárraga K.M.

    2000-01-01

    Full Text Available This study aimed to investigate electrocardiographic changes in dogs aged 5 years or more submitted to two anesthetic combinations: atropine, levomeprazine, thiopental and halothane (ALTH, and atropine, tiletamine and zolazepam (ATZ. Forty dogs (24 males/16 females weighing 5-24kg, were used. Dogs had no cardiac problems and were submitted to tartarectomy. All animals were submitted to two electrocardiograms (ECG, one before anesthesia and other immediately before surgery. The dogs were divided into two groups: group 1 received ALTH and group 2 received ATZ. Alterations in the ST segment, T wave, cardiac rhythm and a significant reduction of vagal tonus index were observed in both groups, but in group 2 a significant reduction of the PR and QT intervals and an increase in heart rate were also observed. These data suggest that the ALTH combination caused fewer changes in the ECG than the ATZ combination.

  20. Non-invasive characterization of normal and pathological tissues through dynamic infrared imaging in the hamster cheek pouch oral cancer model

    Science.gov (United States)

    Herrera, María. S.; Monti Hughes, Andrea; Salva, Natalia; Padra, Claudio; Schwint, Amanda; Santa Cruz, Gustavo A.

    2017-05-01

    Biomedical infrared thermography, a non-invasive and functional imaging method, provides information on the normal and abnormal status and response of tissues in terms of spatial and temporal variations in body infrared radiance. It is especially attractive in cancer research due to the hypervascular and hypermetabolic activity of solid tumors. Moreover, healthy tissues like skin or mucosa exposed to radiation can be examined since inflammation, changes in water content, exudation, desquamation, erosion and necrosis, between others, are factors that modify their thermal properties. In this work we performed Dynamic Infrared Imaging (DIRI) to contribute to the understanding and evaluation of normal tissue, tumor and precancerous tissue response and radiotoxicity in an in vivo model, the hamster cheek pouch, exposed to Boron Neutron Capture Therapy. In this study, we particularly focused on the observation of temperature changes under forced transient conditions associated with mass moisture transfer in the tissue-air interface, in each tissue with or without treatment. We proposed a simple mathematical procedure that considerers the heat transfer from tissue to ambient through convection and evaporation to model the transient (exponential decay o recover) thermal study. The data was fitted to determined the characteristic decay and recovery time constants of the temperature as a function of time. Also this model allowed to explore the mass flux of moisture, as a degree of evaporation occurring on the tissue surface. Tissue thermal responses under provocation tests could be used as a non-invasive method to characterize tissue physiology.

  1. Evaluation of ECG criteria for left ventricular hypertrophy before and after aortic valve replacement using magnetic resonance Imaging

    NARCIS (Netherlands)

    Beyerbacht, Hugo P.; Bax, Jeroen J.; Lamb, Hildo J.; van der Laarse, Arnoud; Vliegen, Hubert W.; de Roos, Albert; Zwinderman, Aeilko H.; van der Wall, Ernst E.

    2003-01-01

    PURPOSE: Evaluation of different electrocardiographic criteria for left ventricular hypertrophy (ECG-LVH criteria) using left ventricular mass index (LVMI) determined by magnetic resonance imaging (MRI). In addition, the relation between LVMI regression after aortic valve replacement and

  2. Non-invasive imaging of acute renal allograft rejection in rats using small animal F-FDG-PET.

    Directory of Open Access Journals (Sweden)

    Stefan Reuter

    Full Text Available BACKGROUND: At present, renal grafts are the most common solid organ transplants world-wide. Given the importance of renal transplantation and the limitation of available donor kidneys, detailed analysis of factors that affect transplant survival are important. Despite the introduction of new and effective immunosuppressive drugs, acute cellular graft rejection (AR is still a major risk for graft survival. Nowadays, AR can only be definitively by renal biopsy. However, biopsies carry a risk of renal transplant injury and loss. Most important, they can not be performed in patients taking anticoagulant drugs. METHODOLOGY/PRINCIPAL FINDINGS: We present a non-invasive, entirely image-based method to assess AR in an allogeneic rat renal transplantation model using small animal positron emission tomography (PET and (18F-fluorodeoxyglucose (FDG. 3 h after i.v. injection of 30 MBq FDG into adult uni-nephrectomized, allogeneically transplanted rats, tissue radioactivity of renal parenchyma was assessed in vivo by a small animal PET-scanner (post operative day (POD 1,2,4, and 7 and post mortem dissection. The mean radioactivity (cps/mm(3 tissue as well as the percent injected dose (%ID was compared between graft and native reference kidney. Results were confirmed by histological and autoradiographic analysis. Healthy rats, rats with acute CSA nephrotoxicity, with acute tubular necrosis, and syngeneically transplanted rats served as controls. FDG-uptake was significantly elevated only in allogeneic grafts from POD 1 on when compared to the native kidney (%ID graft POD 1: 0.54+/-0.06; POD 2: 0.58+/-0.12; POD 4: 0.81+/-0.06; POD 7: 0.77+/-0.1; CTR: 0.22+/-0.01, n = 3-28. Renal FDG-uptake in vivo correlated with the results obtained by micro-autoradiography and the degree of inflammatory infiltrates observed in histology. CONCLUSIONS/SIGNIFICANCE: We propose that graft FDG-PET imaging is a new option to non-invasively, specifically, early detect, and follow

  3. Noninvasive optoacoustic system for rapid diagnostics and management of circulatory shock

    Science.gov (United States)

    Esenaliev, Rinat O.; Petrov, Irene Y.; Petrov, Yuriy; Kinsky, Michael; Prough, Donald S.

    2012-02-01

    Circulatory shock is lethal, if not promptly diagnosed and effectively treated. Typically, circulatory shock resuscitation is guided by blood pressure, heart rate, and mental status, which have poor predictive value. In patients, in whom early goaldirected therapy was applied using central venous oxygenation measurement, a substantial reduction of mortality was reported (from 46.5% to 30%). However, central venous catheterization is invasive, time-consuming and often results in complications. We proposed to use the optoacoustic technique for noninvasive, rapid assessment of central venous oxygenation. In our previous works we demonstrated that the optoacoustic technique can provide measurement of blood oxygenation in veins and arteries due to high contrast and high resolution. In this work we developed a novel optoacoustic system for noninvasive, automatic, real-time, and continuous measurement of central venous oxygenation. We performed pilot clinical tests of the system in human subjects with different oxygenation in the internal jugular vein and subclavian vein. A novel optoacoustic interface incorporating highly-sensitive optoacoustic probes and standard ultrasound imaging probes were developed and built for the study. Ultrasound imaging systems Vivid i and hand-held Vscan (GE Healthcare) as well as Site-Rite 5 (C.R. Bard) were used in the study. We developed a special algorithm for oxygenation monitoring with minimal influence of overlying tissue. The data demonstrate that the system provides precise measurement of venous oxygenation continuously and in real time. Both current value of the venous oxygenation and trend (in absolute values and for specified time intervals) are displayed in the system. The data indicate that: 1) the optoacoustic system developed by our group is capable of noninvasive measurement of blood oxygenation in specific veins; 2) clinical ultrasound imaging systems can facilitate optoacoustic probing of specific blood vessels; 3) the

  4. Non-invasive Assessments of Adipose Tissue Metabolism In Vitro.

    Science.gov (United States)

    Abbott, Rosalyn D; Borowsky, Francis E; Quinn, Kyle P; Bernstein, David L; Georgakoudi, Irene; Kaplan, David L

    2016-03-01

    Adipose tissue engineering is a diverse area of research where the developed tissues can be used to study normal adipose tissue functions, create disease models in vitro, and replace soft tissue defects in vivo. Increasing attention has been focused on the highly specialized metabolic pathways that regulate energy storage and release in adipose tissues which affect local and systemic outcomes. Non-invasive, dynamic measurement systems are useful to track these metabolic pathways in the same tissue model over time to evaluate long term cell growth, differentiation, and development within tissue engineering constructs. This approach reduces costs and time in comparison to more traditional destructive methods such as biochemical and immunochemistry assays and proteomics assessments. Towards this goal, this review will focus on important metabolic functions of adipose tissues and strategies to evaluate them with non-invasive in vitro methods. Current non-invasive methods, such as measuring key metabolic markers and endogenous contrast imaging will be explored.

  5. Noninvasive external cardiac pacing for thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Feldman, M.D.; Warren, S.E.; Gervino, E.V.

    1988-01-01

    Improvements in noninvasive external cardiac pacing have led to a technique with reliable electrical capture and tolerable patient discomfort. To assess the use of this modality of pacing in combination with thallium scintigraphy as a noninvasive pacing stress test, we applied simultaneous noninvasive cardiac pacing, hemodynamic monitoring, and thallium-201 scintigraphy in 14 patients undergoing cardiac catheterization for chest pain syndromes. Two patients had normal coronary arteries, while the remaining 12 had significant coronary artery disease. Thallium scintigraphic responses to pacing were compared to routine exercise thallium stress testing in nine of these 14 patients. All patients were noninvasively paced to more than 85% of the age-predicted maximum heart rate. Twelve patients demonstrated reversible thallium defects, which corresponded in 11 cases to significant lesions seen on coronary angiography. Of nine patients who underwent both pacing and exercise thallium stress tests, comparable maximal rate-pressure products were achieved. Moreover, thallium imaging at peak pacing and during delayed views did not differ significantly from exercise thallium scintigraphy. A limiting factor associated with the technique was local patient discomfort, which occurred to some degree in all patients. We conclude that noninvasive external cardiac pacing together with thallium scintigraphy is capable of detecting significant coronary artery disease and may be comparable to routine exercise thallium stress testing. This new modality of stress testing could be useful in patients unable to undergo the exercise required for standard exercise tolerance testing, particularly if improvements in the technology can be found to reduce further the local discomfort

  6. Non-invasive diagnostic methods in dentistry

    Science.gov (United States)

    Todea, Carmen

    2016-03-01

    The paper, will present the most important non-invasive methods for diagnostic, in different fields of dentistry. Moreover, the laser-based methods will be emphasis. In orthodontics, 3D laser scanners are increasingly being used to establish database for normative population and cross-sectional growth changes but also to asses clinical outcomes in orthognatic surgical and non-surgical treatments. In prevention the main methods for diagnostic of demineralization and caries detection in early stages are represented by laser fluorescence - Quantitative Light Florescence (QLF); DiagnoDent-system-655nm; FOTI-Fiberoptic transillumination; DIFOTI-Digital Imaging Fiberoptic transillumination; and Optical Coherence Tomography (OCT). In odontology, Laser Doppler Flowmetry (LDF) is a noninvasive real time method used for determining the tooth vitality by monitoring the pulp microcirculation in traumatized teeth, fractured teeth, and teeth undergoing different conservative treatments. In periodontology, recently study shows the ability of LDF to evaluate the health of gingival tissue in periodontal tissue diseases but also after different periodontal treatments.

  7. Uncontrolled hypertension is associated with coronary artery calcification and electrocardiographic left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Nielsen, Mette Lundgren; Pareek, Manan; Gerke, O

    2015-01-01

    We conducted a 1:2 matched case-control study in order to evaluate whether the prevalence of coronary artery calcium (CAC) and electrocardiographic left ventricular hypertrophy (LVH) or strain was higher in patients with uncontrolled hypertension than in subjects from the general population......, and evaluate the association between CAC and LVH in patients with uncontrolled hypertension. Cases were patients with uncontrolled hypertension, whereas the controls were random individuals from the general population without cardiovascular disease. CAC score was assessed using a non-contrast computed...

  8. Flattening of the electrocardiographic T-wave is a sign of proarrhythmic risk and a reflection of action potential triangulation

    DEFF Research Database (Denmark)

    Bhuiyan, Tanveer Ahmed; Graff, Claus; Kanters, J.K.

    2013-01-01

    Drug-induced triangulation of the cardiac action potential is associated with increased risk of arrhythmic events. It has been suggested that triangulation causes a flattening of the electrocardiographic T-wave but the relationship between triangulation, T-wave flattening and onset of arrhythmia ...

  9. Recent research findings on non-invasive diagnosis of liver fibrosis

    Directory of Open Access Journals (Sweden)

    WU Qiong

    2015-02-01

    Full Text Available Early diagnosis of liver fibrosis and dynamic monitoring of relevant changes have great implications for the treatment and prognosis improvement of chronic liver diseases. So far, liver biopsy remains the “golden standard” for the diagnosis and staging of liver fibrosis. However, due to its inherent limitations, a great effort has been made to develop more accurate non-invasive diagnostic methods, including serum fibrosis markers and mathematical models, ultrasound, contrast-enhanced ultrasonography, ultrasonic elastography, computed tomography, magnetic resonance imaging, and nuclear medicine. The advantages and disadvantages of relevant methods are discussed. Furthermore, proper selection of the non-invasive diagnostic methods for clinical application and the means for mutual verification are analyzed. As for the future direction, it is expected to employ the above methods for combined analysis and comprehensive assessment, in order to enhance the clinical value of non-invasive liver fibrosis diagnosis.

  10. Wavelength-Modulated Differential Photoacoustic (WM-DPA) imaging: a high dynamic range modality towards noninvasive diagnosis of cancer

    Science.gov (United States)

    Dovlo, Edem; Lashkari, Bahman; Choi, Sung soo Sean; Mandelis, Andreas

    2016-03-01

    This study explores wavelength-modulated differential photo-acoustic (WM-DPA) imaging for non-invasive early cancer detection via sensitive characterization of functional information such as hemoglobin oxygenation (sO2) levels. Well-known benchmarks of tumor formation such as angiogenesis and hypoxia can be addressed this way. While most conventional photo-acoustic imaging has almost entirely employed high-power pulsed lasers, frequency-domain photo-acoustic radar (FD-PAR) has seen significant development as an alternative technique. It employs a continuous wave laser source intensity-modulated and driven by frequency-swept waveforms. WM-DPA imaging utilizes chirp modulated laser beams at two distinct wavelengths for which absorption differences between oxy- and deoxygenated hemoglobin are minimum (isosbestic point, 805 nm) and maximum (680 nm) to simultaneously generate two signals detected using a standard commercial array transducer as well as a single-element transducer that scans the sample. Signal processing is performed using Lab View and Matlab software developed in-house. Minute changes in total hemoglobin concentration (tHb) and oxygenation levels are detectable using this method since background absorption is suppressed due to the out-of-phase modulation of the laser sources while the difference between the two signals is amplified, thus allowing pre-malignant tumors to become identifiable. By regulating the signal amplitude ratio and phase shift the system can be tuned to applications like cancer screening, sO2 quantification and hypoxia monitoring in stroke patients. Experimental results presented demonstrate WM-DPA imaging of sheep blood phantoms in comparison to single-wavelength FD-PAR imaging. Future work includes the functional PA imaging of small animals in vivo.

  11. Comparative analysis of a portable smartphone­based electrocardiograph (D­Heart® versus standard 6­leads electrocardiograph in the canine patient.

    Directory of Open Access Journals (Sweden)

    Alice Savarese

    2017-05-01

    Full Text Available D-Heart® is a portable, smartphone-based device, which streams tracing via Bluetooth, enabling multiple leads electrocardiograms (ECGs acquisition, currently used in human cardiology (Maurizi et al. 2017. The aim was to determine the accuracy of D­Heart® compared with the gold standard non­portable 6­lead electrocardiograph in the evaluation of cardiac rhythm in dogs. Standard 6­lead and D­Heart® ECGs were acquired in conscious dogs. Concordance between methods was assessed by weighted k Cohen index, with its relative significance, taking as end point variable standard 6­lead ECG group. Bland ­ Altman method (95% confidence level was applied for P, PR, QRS, T and QT. Since differences didn’t follow a normal distribution, a non­parametric approach was used to determine limits of agreement. P was significant when < 0.05 (Maurizi et al. 2017. Amplitude of waves was not considered because currently the software doesn’t allow voltage variation. 115 dogs of different weights and breeds admitted to the Cardiology Service of DIMEVET were enrolled. Mean age was 7,5±4 years. Most were intact males (45%, n=51. The most represented breed was mongrel (27%, n=32. Weighted Cohen's kappa test demonstrated excellent concordance in the evaluation of the heart rhythm (0.989, p<0.001, for ST segment morphology (0.991, p<0,001 and for T wave morphology (0.838, p=0.040. There was a 100% concordance in P morphology determination. P, PR, QRS, T and QT intervals comparison with Bland­Altman showed an extremely good concordance for D­Heart® measurements (95% limit of agreement ±0.9 ms for P, ±10 ms for PR, ±35 ms for QRS, ±5 ms for T wave. Less concordance resulted for QT (±80 ms. In Conclusion, D­Heart® proved effective accurate recording of ECG comparable to standard 6­lead electrocardiographs, opening new perspectives to improve diagnostic tools in veterinary cardiology. Future perspective will be the development of a telecardiology network

  12. Noninvasive IDH1 mutation estimation based on a quantitative radiomics approach for grade II glioma.

    Science.gov (United States)

    Yu, Jinhua; Shi, Zhifeng; Lian, Yuxi; Li, Zeju; Liu, Tongtong; Gao, Yuan; Wang, Yuanyuan; Chen, Liang; Mao, Ying

    2017-08-01

    The status of isocitrate dehydrogenase 1 (IDH1) is highly correlated with the development, treatment and prognosis of glioma. We explored a noninvasive method to reveal IDH1 status by using a quantitative radiomics approach for grade II glioma. A primary cohort consisting of 110 patients pathologically diagnosed with grade II glioma was retrospectively studied. The radiomics method developed in this paper includes image segmentation, high-throughput feature extraction, radiomics sequencing, feature selection and classification. Using the leave-one-out cross-validation (LOOCV) method, the classification result was compared with the real IDH1 situation from Sanger sequencing. Another independent validation cohort containing 30 patients was utilised to further test the method. A total of 671 high-throughput features were extracted and quantized. 110 features were selected by improved genetic algorithm. In LOOCV, the noninvasive IDH1 status estimation based on the proposed approach presented an estimation accuracy of 0.80, sensitivity of 0.83 and specificity of 0.74. Area under the receiver operating characteristic curve reached 0.86. Further validation on the independent cohort of 30 patients produced similar results. Radiomics is a potentially useful approach for estimating IDH1 mutation status noninvasively using conventional T2-FLAIR MRI images. The estimation accuracy could potentially be improved by using multiple imaging modalities. • Noninvasive IDH1 status estimation can be obtained with a radiomics approach. • Automatic and quantitative processes were established for noninvasive biomarker estimation. • High-throughput MRI features are highly correlated to IDH1 states. • Area under the ROC curve of the proposed estimation method reached 0.86.

  13. Electrocardiographic findings in athletes: the prevalence of left ventricular hypertrophy and conduction defects.

    Science.gov (United States)

    Langdeau, J B; Blier, L; Turcotte, H; O'Hara, G; Boulet, L P

    2001-06-01

    To determine whether there are electrocardiographic differences or distinctive abnormalities between athletes and sedentary subjects, and to verify the relationship between vagal activity measured by heart rate variability (SD of all normal-to-normal intervals [SDNN]) and possible electrocardiographic abnormalities. Resting electrocardiograms and heart rate variability measurements were performed separately during a single visit on 100 athletes and 50 nonathlete control subjects aged 18 to 55 years. The athletes were from the following various sports disciplines: long-distance running, mountain biking, cross-country skiing, biathlon, speed skating, swimming and triathlon. There were significantly longer RR intervals, PR intervals and QT intervals in athletes than in control subjects (all P0.05). The prevalence of left ventricular hypertrophy (LVH) and incomplete right bundle branch block (IRBBB) was 10% and 7%, respectively, in athletes, but these conditions were absent in control subjects; among athletes, 2% presented with both conditions. LVH and IRBBB were more common among long-distance runners (six of 14 and four of 14, respectively) and could be attributed to normal, long term adaptation to intense, repeated exercise. LVH was related to age (P=0.04), whereas IRBBB was influenced by the number of years of training in the respective sports discipline (P=0.03). The mean SDNN value was significantly more elevated in athletes (P=0.0001), reflecting a higher parasympathetic tone than in sedentary control subjects. However, there was no relationship between vagal activity and LVH or IRBBB (both P>0.05).

  14. Optimized intravenous flat detector CT for non-invasive visualization of intracranial stents: first results

    International Nuclear Information System (INIS)

    Struffert, Tobias; Kloska, Stephan; Engelhorn, Tobias; Ott, Sabine; Doelken, Marc; Saake, Marc; Doerfler, Arnd; Deuerling-Zheng, Yu.; Koehrmann, Martin

    2011-01-01

    As stents for treating intracranial atherosclerotic stenosis may develop in-stent re-stenosis (ISR) in up to 30%, follow-up imaging is mandatory. Residual stenosis (RS) is not rare. We evaluated an optimised Flat Detector CT protocol with intravenous contrast material application (i.v. FD-CTA) for non-invasive follow-up. In 12 patients with intracranial stents, follow-up imaging was performed using i.v. FD-CTA. MPR, subtracted MIP and VRT reconstructions were used to correlate to intra-arterial angiography (DSA). Two neuroradiologists evaluated the images in anonymous consensus reading and calculated the ISR or RS. Correlation coefficients and a Wilcoxon test were used for statistical analysis. In 4 patients, no stenosis was detected. In 6 patients RS and in two cases ISR by intima hyperplasia perfectly visible on MPR reconstructions of i.v. FD-CTA were detected. Wilcoxon's test showed no significant differences between the methods (p > 0.05). We found a high correlation with coefficients of the pairs DSA/ FD-CT MIP r = 0.91, DSA/ FD-CT MPR r = 0.82 and FD-CT MIP/ FD-CT MPR r = 0.8. Intravenous FD-CTA could clearly visualise the stent and the lumen, allowing ISR or RS to be recognised. FD-CTA provides a non-invasive depiction of intracranial stents and might replace DSA for non-invasive follow-up imaging. (orig.)

  15. A new approach for low-cost noninvasive detection of asymptomatic heart disease at rest.

    Science.gov (United States)

    DeMarzo, Arthur P; Calvin, James E

    2007-01-01

    It would be useful to have an inexpensive, noninvasive point-of-care test for early detection of asymptomatic heart disease. This study used impedance cardiography (ICG) in a new way to assess heart function that did not use stroke volume or cardiac output. There is a model of the ICG dZ/dt waveform that may be used as a template to represent normal heart function. The hypothesis was that a dZ/dt waveform which deviates from that template should indicate heart dysfunction and therefore heart disease. The objective was to assess the accuracy of this new ICG approach, using echocardiography as the standard. Thirty-four outpatients undergoing echocardiographic testing were tested by ICG while sitting upright and supine. All patients had no symptoms or history of a structural or functional heart disorder. Echocardiographic testing showed 17 patients with abnormalities and 17 as normal. ICG testing yielded 16 true positives for heart dysfunction with 1 false negative (sensitivity = 94%) and 17 true negatives with no false positives (specificity = 100%). Considering that the cost, technical skill, and time required for this ICG test are comparable to those of an electrocardiograph, this new approach has potential as a point-of-care screening test for asymptomatic heart disease.

  16. Asynchrony of the early maturation of white matter bundles in healthy infants: Quantitative landmarks revealed noninvasively by diffusion tensor imaging

    International Nuclear Information System (INIS)

    Dubois, J.; Perrin, M.; Mangin, J.F.; Cointepas, Y.; Duchesnay, E.; Le Bihan, D.; Hertz-Pannier, L.; Dehaene-Lambertz, G.; Dubois, J.; Dehaene-Lambertz, G.; Perrin, M.; Mangin, J.F.; Cointepas, Y.; Duchesnay, E.; Le Bihan, D.; Hertz-Pannier, L.

    2008-01-01

    Normal cognitive development in infants follows a well-known temporal sequence, which is assumed to be correlated with the structural maturation of underlying functional networks. Postmortem studies and, more recently, structural MR imaging studies have described qualitatively the heterogeneous spatio-temporal progression of white matter myelination. However, in vivo quantification of the maturation phases of fiber bundles is still lacking. We used noninvasive diffusion tensor MR imaging and tractography in twenty-three 1-4-month-old healthy infants to quantify the early maturation of the main cerebral fascicles. A specific maturation model, based on the respective roles of different maturational processes on the diffusion phenomena, was designed to highlight asynchronous maturation across bundles by evaluating the time-course of mean diffusivity and anisotropy changes over the considered developmental period. Using an original approach, a progression of maturation in four relative stages was determined in each tract by estimating the maturation state and speed, from the diffusion indices over the infants group compared with an adults group on one hand, and in each tract compared with the average over bundles on the other hand. Results were coherent with, and extended previous findings in 8 of 11 bundles, showing the anterior limb of the internal capsule and cingulum as the most immature, followed by the optic radiations, arcuate and inferior longitudinal fascicles, then the spino-thalamic tract and fornix, and finally the cortico-spinal tract as the most mature bundle. Thus, this approach provides new quantitative landmarks for further noninvasive research on brain-behavior relationships during normal and abnormal development. (authors)

  17. Noninvasive Assessment of Cell Fate and Biology in Transplanted Mesenchymal Stem Cells.

    Science.gov (United States)

    Franchi, Federico; Rodriguez-Porcel, Martin

    2017-01-01

    Recently, molecular imaging has become a conditio sine qua non for cell-based regenerative medicine. Developments in molecular imaging techniques, such as reporter gene technology, have increasingly enabled the noninvasive assessment of the fate and biology of cells after cardiovascular applications. In this context, bioluminescence imaging is the most commonly used imaging modality in small animal models of preclinical studies. Here, we present a detailed protocol of a reporter gene imaging approach for monitoring the viability and biology of Mesenchymal Stem Cells transplanted in a mouse model of myocardial ischemia reperfusion injury.

  18. Electrocardiographic Changes in Certain Cardiovascular Physiological and Pathological Settings. Impact on Coronary Artery Bypass Grafting

    Directory of Open Access Journals (Sweden)

    Dimitar Simov

    2016-03-01

    Full Text Available Review on electrocardiographic changes provoked by aging, diagnostic tests, cardiac surgery, hemodialysis, diabetes, etc., is the objective of the current material. Several electrocardiographic (ECG parameters that are well known risk markers of arrhythmias, incidental heart failure and sudden cardiac death (SCD are discussed: QRS amplitude, QRS morphology, QRS duration, QRS alternans, T-wave amplitude, T-wave morphology, T-wave alternans, negative T-waves, 3D-spatial angle between maximal QRS and T vectors of the vectorcardiographic loops, ST-segment elevation, QT-interval dispersion, and heart rate. All reviewed parameters are compared with the results on the ECG-alterations, induced by coronary artery bypass grafting (CABG surgery. Two parameters showed an improvement in the patients' condition: QRS-T angle and cardiac autonomic innervation while two others (T-wave alternans and heart rate indicated deterioration. We tend to assume that the deterioration in this early post-operative period is an effect of the post-surgery trauma. We speculate that this effect will fade away in a period of a month and more after surgery, and we intend to conduct such a research in the future. The analysis of ECG's changes will help to better assess the impact of the CABG surgery.

  19. Noninvasive tomographic and velocimetric monitoring of multiphase flows

    International Nuclear Information System (INIS)

    Chaouki, J.; Dudukovic, M.P.

    1997-01-01

    A condensed review of recent advances accomplished in the development and the applications of noninvasive tomographic and velocimetric measurement techniques to multiphase flows and systems is presented. In recent years utilization of such noninvasive techniques has become widespread in many engineering disciplines that deal with systems involving two immiscible phases or more. Tomography provides concentration, holdup, or 2D or 3D density distribution of at least one component of the multiphase system, whereas velocimetry provides the dynamic features of the phase of interest such as the flow pattern, the velocity field, the 2D or 3D instantaneous movements, etc. The following review is divided into two parts. The first part summarizes progress and developments in flow imaging techniques using γ-ray and X-ray transmission tomography; X-ray radiography; neutron transmission tomography and radiography; positron emission tomography; X-ray diffraction tomography; nuclear magnetic resonance imaging; electrical capacitance tomography; optical tomography; microwave tomography; and ultrasonic tomography. The second part of the review summarizes progress and developments in the following velocimetry techniques: positron emission particle tracking; radioactive particle tracking; cinematography; laser-Doppler anemometry; particle image velocimetry; and fluorescence particle image velocimetry. The basic principles of tomography and velocimetry techniques are outlined, along with advantages and limitations inherent to each technique. The hydrodynamic and structural information yielded by these techniques is illustrated through a literature survey on their successful applications to the study of multiphase systems in such fields as particulate solids processes, fluidization engineering, porous media, pipe flows, transport within packed beds and sparged reactors, etc

  20. Exercise electrocardiographic responses and serum cystatin C levels among metabolic syndrome patients without overt diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Tanindi A

    2011-02-01

    Full Text Available Asli Tanindi1 Hilal Olgun1 Ayse Tuncel2 Bulent Celik3 Hatice Pasaoglu2 Bulent Boyaci11Department of Cardiology, 2Department of Medical Biochemistry, Faculty of Medicine, 3Department of Statistics, Faculty of Health Sciences, Gazi University, Ankara, TurkeyObjectives: An impaired heart rate response during exercise (chronotropic incompetence and an impaired heart rate recovery (HRR after exercise are predictors of cardiovascular risk and mortality. Cystatin C is a novel marker for cardiovascular disease. We aimed to investigate exercise electrocardiographic responses in patients with metabolic syndrome who were without overt diabetes mellitus, in addition to the association of serum cystatin C levels with the exercise electrocardiographic test results.Method: Forty-three consecutive patients admitted to a cardiology outpatient clinic without angina pectoris were recruited if they met criteria for metabolic syndrome but did not have overt diabetes mellitus. Serum cystatin C levels were measured, and all participants underwent exercise electrocardiographic testing. Patients who were found to have ischemia had a coronary angiography procedure.Results: The mean cystatin C level of patients was higher in metabolic syndrome group than healthy controls (610.1 ± 334.02 vs 337.3 ± 111.01 µg/L; P < 0.001. The percentage of patients with ischemia confirmed by coronary angiography was 13.9% in the metabolic syndrome group. Cystatin C levels in the ischemic patients of the metabolic syndrome group were higher than that in nonischemic patients (957.00 ± 375.6 vs 553.8 ± 295.3 µg /L; P = 0.005. Chronotropic incompetence was observed in 30.2% of the patients with metabolic syndrome compared with 16.7% in the control group (P = 0.186. Chronotropic response indices were 0.8 ± 0.18 versus 0.9 ± 0.10 for the two groups, respectively (P = 0.259. HRR was significantly lower in the metabolic syndrome patients compared with the controls (20.1 ± 8.01 vs 25.2

  1. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  2. Noninvasive photoacoustic computed tomography of mouse brain metabolism in vivo

    Science.gov (United States)

    Yao, Junjie; Xia, Jun; Maslov, Konstantin; Avanaki, Mohammadreza R. N.; Tsytsarev, Vassiliy; Demchenko, Alexei V.; Wang, Lihong V.

    2013-03-01

    To control the overall action of the body, brain consumes a large amount of energy in proportion to its volume. In humans and many other species, the brain gets most of its energy from oxygen-dependent metabolism of glucose. An abnormal metabolic rate of glucose and/or oxygen usually reflects a diseased status of brain, such as cancer or Alzheimer's disease. We have demonstrated the feasibility of imaging mouse brain metabolism using photoacoustic computed tomography (PACT), a fast, noninvasive and functional imaging modality with optical contrast and acoustic resolution. Brain responses to forepaw stimulations were imaged transdermally and transcranially. 2-NBDG, which diffuses well across the blood-brain-barrier, provided exogenous contrast for photoacoustic imaging of glucose response. Concurrently, hemoglobin provided endogenous contrast for photoacoustic imaging of hemodynamic response. Glucose and hemodynamic responses were quantitatively unmixed by using two-wavelength measurements. We found that glucose uptake and blood perfusion around the somatosensory region of the contralateral hemisphere were both increased by stimulations, indicating elevated neuron activity. The glucose response amplitude was about half that of the hemodynamic response. While the glucose response area was more homogenous and confined within the somatosensory region, the hemodynamic response area showed a clear vascular pattern and spread about twice as wide as that of the glucose response. The PACT of mouse brain metabolism was validated by high-resolution open-scalp OR-PAM and fluorescence imaging. Our results demonstrate that 2-NBDG-enhanced PACT is a promising tool for noninvasive studies of brain metabolism.

  3. Noninvasive optoacoustic system for rapid diagnosis and management of circulatory shock

    Science.gov (United States)

    Petrov, Irene Y.; Kinsky, Michael; Petrov, Yuriy; Petrov, Andrey; Henkel, S. N.; Seeton, Roger; Esenaliev, Rinat O.; Prough, Donald S.

    2013-03-01

    Circulatory shock can lead to death or severe complications, if not promptly diagnosed and effectively treated. Typically, diagnosis and management of circulatory shock are guided by blood pressure and heart rate. However, these variables have poor specificity, sensitivity, and predictive value. Early goal-directed therapy in septic shock patients, using central venous catheterization (CVC), reduced mortality from 46.5% to 30%. However, CVC is invasive and complication-prone. We proposed to use an optoacoustic technique for noninvasive, rapid assessment of peripheral and central venous oxygenation. In this work we used a medical grade optoacoustic system for noninvasive, ultrasound image-guided measurement of central and peripheral venous oxygenation. Venous oxygenation during shock declines more rapidly in the periphery than centrally. Ultrasound imaging of the axillary [peripheral] and internal jugular vein [central] was performed using the Vivid e (GE Healthcare). We built an optoacoustic interface incorporating an optoacoustic transducer and a standard ultrasound imaging probe. Central and peripheral venous oxygenations were measured continuously in healthy volunteers. To simulate shock-induced changes in central and peripheral oxygenation, we induced peripheral vasoconstriction in the upper extremity by using a cooling blanket. Central and peripheral venous oxygenations were measured before (baseline) and after cooling and after rewarming. During the entire experiment, central venous oxygenation was relatively stable, while peripheral venous oxygenation decreased by 5-10% due to cooling and recovered after rewarming. The obtained data indicate that noninvasive, optoacoustic measurements of central and peripheral venous oxygenation may be used for diagnosis and management of circulatory shock with high sensitivity and specificity.

  4. Hidradenitis Suppurativa and electrocardiographic changes - a cross-sectional population study

    DEFF Research Database (Denmark)

    Juhl, C R; Miller, I M; Jemec, G B

    2018-01-01

    BACKGROUND: Hidradenitis Suppurativa (HS) is a chronic, inflammatory skin disease, recently associated with metabolic syndrome, subclinical atherosclerosis and increased risk of cardiovascular disease. OBJECTIVES: The aim of the study was to investigate the hitherto unknown electrocardiographic c...... resting electrocardiograms. We investigated the difference in means by unpaired t-test or the analysis of variance (ANOVA) test. RESULTS: Heart rate was significantly higher (mean difference: 2.3 bpm [1.2:3.4] p..., there was no significant difference (0.3 bpm [-0.7:1.4] p=0.52). Severe HS was significantly associated with increased heart rate across all models (2.9 bpm [0.7:5.1] p=0.01). Mean QRS-duration was significantly shorter in the mild HS group, but not in the moderate- and severe HS groups CONCLUSION: Mean resting heart rate...

  5. Non-invasive coronary angiography with multislice computed tomography. Technology, methods, preliminary experience and prospects.

    Science.gov (United States)

    Traversi, Egidio; Bertoli, Giuseppe; Barazzoni, Giancarlo; Baldi, Maurizia; Tramarin, Roberto

    2004-02-01

    The recent technical developments in multislice computed tomography (MSCT), with ECG retro-gated image reconstruction, have elicited great interest in the possibility of accurate non-invasive imaging of the coronary arteries. The latest generation of MSCT systems with 8-16 rows of detectors permits acquisition of the whole cardiac volume during a single 15-20 s breath-hold with a submillimetric definition of the images and an outstanding signal-to-noise ratio. Thus the race which, between MSCT, electron beam computed tomography and cardiac magnetic resonance imaging, can best provide routine and reliable imaging of the coronary arteries in clinical practice has recommenced. Currently available MSCT systems offer different options for both cardiac image acquisition and reconstruction, including multiplanar and curved multiplanar reconstruction, three-dimensional volume rendering, maximum intensity projection, and virtual angioscopy. In our preliminary experience including 176 patients suffering from known or suspected coronary artery disease, MSCT was feasible in 161 (91.5%) and showed a sensitivity of 80.4% and a specificity of 80.3%, with respect to standard coronary angiography, in detecting critical stenosis in coronary arteries and artery or venous bypass grafts. These results correspond to a positive predictive value of 58.6% and a negative predictive value of 92.2%. The true role that MSCT is likely to play in the future in non-invasive coronary imaging is still to be defined. Nevertheless, the huge amount of data obtainable by MSCT along with the rapid technological advances, shorter acquisition times and reconstruction algorithm developments will make the technique stronger, and possible applications are expected not only for non-invasive coronary angiography, but also for cardiac function and myocardial perfusion evaluation, as an all-in-one examination.

  6. Extraction of the fetal ECG in noninvasive recordings by signal decompositions

    International Nuclear Information System (INIS)

    Christov, I; Simova, I; Abächerli, R

    2014-01-01

    No signal processing technique has been able to reliably deliver an undistorted fetal electrocardiographic (fECG) signal from electrodes placed on the maternal abdomen because of the low signal-to-noise ratio of the fECG recorded from the maternal body surface. As a result, this led to increased rates of Caesarean deliveries of healthy infants. In an attempt to solve the problem, Physionet/Computing in Cardiology announced the 2013 Challenge: noninvasive fetal ECG. We are suggesting a method for cancellation of the maternal ECG consisting of: maternal QRS detection, heart rate dependant P-QRS-T interval selection, location of the fiducial points inside this interval for best matching by cross correlation, superimposition of the intervals, calculation of the mean signal of the P-QRS-T interval, and sequential subtraction of the mean signal from the whole fECG recording. Three signal decomposition methods were further applied in order to enhance the fetal QRSs (fQRS): principal component analysis, root-mean-square and Hotelling’s T-squared. A combined lead of all decompositions was synthesized and fQRS detection was performed on it. The current research differs from the Challenge in that it uses three signal decomposition methods to enhance the fECG. The new results for 97 recordings of test set B are: 305.657 for Event 4: Fetal heart rate (FHR) and 23.062 for Event 5: Fetal RR interval (FRR). (paper)

  7. Imaging modalities for the non-invasive diagnosis of endometriosis.

    Science.gov (United States)

    Nisenblat, Vicki; Bossuyt, Patrick M M; Farquhar, Cindy; Johnson, Neil; Hull, M Louise

    2016-02-26

    About 10% of women of reproductive age suffer from endometriosis. Endometriosis is a costly chronic disease that causes pelvic pain and subfertility. Laparoscopy, the gold standard diagnostic test for endometriosis, is expensive and carries surgical risks. Currently, no non-invasive tests that can be used to accurately diagnose endometriosis are available in clinical practice. This is the first review of diagnostic test accuracy of imaging tests for endometriosis that uses Cochrane methods to provide an update on the rapidly expanding literature in this field. • To provide estimates of the diagnostic accuracy of imaging modalities for the diagnosis of pelvic endometriosis, ovarian endometriosis and deeply infiltrating endometriosis (DIE) versus surgical diagnosis as a reference standard.• To describe performance of imaging tests for mapping of deep endometriotic lesions in the pelvis at specific anatomical sites.Imaging tests were evaluated as replacement tests for diagnostic surgery and as triage tests that would assist decision making regarding diagnostic surgery for endometriosis. We searched the following databases to 20 April 2015: MEDLINE, CENTRAL, EMBASE, CINAHL, PsycINFO, Web of Science, LILACS, OAIster, TRIP, ClinicalTrials.gov, MEDION, DARE, and PubMed. Searches were not restricted to a particular study design or language nor to specific publication dates. The search strategy incorporated words in the title, abstracts, text words across the record and medical subject headings (MeSH). We considered published peer-reviewed cross-sectional studies and randomised controlled trials of any size that included prospectively recruited women of reproductive age suspected of having one or more of the following target conditions: endometrioma, pelvic endometriosis, DIE or endometriotic lesions at specific intrapelvic anatomical locations. We included studies that compared the diagnostic test accuracy of one or more imaging modalities versus findings of surgical

  8. A red fluorescent nude mouse model of human endometriosis: advantages of a non-invasive imaging method.

    Science.gov (United States)

    Wang, Ningning; Hong, Shanshan; Tan, Jinfeng; Ke, Peiqi; Liang, Lili; Fei, Hui; Liu, Bin; Liu, Liqun; Liu, Yongdong; Yu, Bingjun

    2014-05-01

    To establish red fluorescent human endometriosis lesions in a nude mouse model and dynamically and non-invasively to compare intraperitoneal and subcutaneous injection models. Primary cultures of endometrial stromal cells (ESCs) and epithelial cells (EECs) isolated from 24 patients with a normal uterine cavity were transfected with 2.5×10(8) (Group 1) and 1.25×10(8) (Group 2) plaque-forming units (PFU) of adenovirus encoding red fluorescent protein (Ad-RFP). Transfection efficiencies, fluorescence intensity and apoptosis rate of the two types of cells were compared in vitro. A mixture of 2.5×10(8) PFU Ad-RFP-infected approximately 400 EECs cell mass and 2×10(6) ESCs for 36h was injected individually into 24 female nude mice subcutaneously (Group A) or intraperitoneally (Group B). From Day 5 after injection, an in vivo imaging system (IVIS) was used to non-invasively observe and compare the lesions of the two groups every week until Day 33. Specifically, the fluorescent intensity, positive rates, persistence time and lesion weight in the implanted human endometriosis lesions were compared. A parametric Student's t-test and two-way analysis of variance were used for statistical analysis. Compared with 1.25×10(8) PFU RFP, a titre of 2.5×10(8) PFU RFP ESCs and EECs incubated for 36h exhibited higher transfection efficiencies and higher fluorescence intensities in vitro. In vivo imaging of the fluorescent human endometriosis lesions originating from an RFP titre of 2.5×10(8) PFU showed that the intensity and lesion weight in Group A were significantly higher than in Group B. However, the two groups had the same RFP-positive rates and fluorescence persistence. The structure of each lesion was evaluated by immunohistochemistry to confirm its human endometrial origin. The red fluorescent human endometriosis model established by subcutaneously injecting 2.5×10(8) PFU RFP-transfected stromal cells and epithelial cells into nude mice had a higher fluorescent positive

  9. MRI Reporter Genes for Noninvasive Molecular Imaging

    Directory of Open Access Journals (Sweden)

    Caixia Yang

    2016-05-01

    Full Text Available Magnetic resonance imaging (MRI is one of the most important imaging technologies used in clinical diagnosis. Reporter genes for MRI can be applied to accurately track the delivery of cell in cell therapy, evaluate the therapy effect of gene delivery, and monitor tissue/cell-specific microenvironments. Commonly used reporter genes for MRI usually include genes encoding the enzyme (e.g., tyrosinase and β-galactosidase, the receptor on the cells (e.g., transferrin receptor, and endogenous reporter genes (e.g., ferritin reporter gene. However, low sensitivity limits the application of MRI and reporter gene-based multimodal imaging strategies are common including optical imaging and radionuclide imaging. These can significantly improve diagnostic efficiency and accelerate the development of new therapies.

  10. Measurement of non-invasive X-ray measuring instruments

    International Nuclear Information System (INIS)

    Abe, Shinji

    2013-01-01

    Described are the history, measuring system, characteristics and present state of the instruments in the title (NXMI). NXMI, non-invasive to the inner circuit of X-ray generator, is now essential for the quality control of generator with reference to definitions by International Electrotechnical Commission (IEC) and Japan Industrial Standards (JIS). Non-invasive measurement of the generator's tube voltage in 1944 is the first report where the absorption difference of Cu plates with different thickness is used. At present, NXMI, being compact, can measure multiple properties of X-ray generated, such as the tube voltage (TV), current (TC), imaging time, dose/dose rate, total filtration, half value layer, and TV/output waveform. TV is measurable by the penetration difference of X-rays through Cu filters of different thickness, which is a linear function of TV; TC, with the clamp-type ammeter placed at the generator high voltage cable; and the dose, with the semiconductor detector. Characteristics can be evaluable within the upper trigger level of the detector (radiation time, dose measured here), in which measured are the irradiation (imaging) time, delay time, and TV (within the window width). Authors' practical quality control of the generator is conducted through calibration for which data are obtained by invasive (direct) precise measurement of TV, TC, imaging time and dose with reference to JIS. Periodical calibration and consequent quality control of NXMI are essential for the maintenance of precision of the generator. (T.T.)

  11. A fast analysis method for non-invasive imaging of blood flow in individual cerebral arteries using vessel-encoded arterial spin labelling angiography

    Science.gov (United States)

    Chappell, Michael A.; Okell, Thomas W.; Payne, Stephen J.; Jezzard, Peter; Woolrich, Mark W.

    2012-01-01

    Arterial spin labelling (ASL) MRI offers a non-invasive means to create blood-borne contrast in vivo for dynamic angiographic imaging. By spatial modulation of the ASL process it is possible to uniquely label individual arteries over a series of measurements, allowing each to be separately identified in the resulting angiographic images. This separation requires appropriate analysis for which a general Bayesian framework has previously been proposed. Here this framework is adapted for clinical dynamic angiographic imaging. This specifically addresses the issues of computational speed of the algorithm and the robustness required to deal with real patient data. An algorithm is proposed that can incorporate planning information about the arteries being imaged whilst adapting for subsequent patient movement. A fast maximum a posteriori solution is adopted and shown to be only marginally less accurate than Monte Carlo sampling under simulation. The final algorithm is demonstrated on in vivo data with analysis on a time scale of the order of 10 min, from both a healthy control and a patient with a vertebro-basilar occlusion. PMID:22322066

  12. Three-dimensional surface reconstruction imaging for evaluation of congenital heart disease from ECG-triggered MR images

    International Nuclear Information System (INIS)

    Vannier, M.W.; Laschinger, J.; Knapp, R.H.; Gutierrez, F.R.; Gronnemeyer, S.A.

    1987-01-01

    Three-dimensional surface reconstruction images of the heart and great vessels were produced from contiguous sequences of electrocardiographically triggered MR images in 25 patients with congenital heart disease and in three healthy subjects. The imaging data were semiautomatically processed to separate the epicardial and endocardial surfaces and to define the outline of the enclosed blood volumes on a section by section basis. Images were obtained at 5-mm intervals in patients aged 3 months to 30 years with anomalies of the great vessels, tetralogy of Fallot, septal defects, pulmonary atresia, and other congenital heart malformations. The results were used to facilitate the surgical treatment of these patients and were compared with echocardiographic and cineradiographic studies, and with surgical findings or pathologic specimens. These surface reconstruction images were useful for communicating the results of diagnostic examinations to cardiac surgeons, for sizing and location of intracardiac defects, for imaging the pulmonary venous drainage, and for assessing regional and global function

  13. Electrocardiographic Manifestations of Benzodiazepine Toxicity

    Directory of Open Access Journals (Sweden)

    Nahid Kazemzadeh

    2014-11-01

    Full Text Available Background: The aim of this study was to evaluate and compare the clinical and electrocardiographic (ECG manifestations of benzodiazepines (BZs. Methods: In this retrospective study, all BZ-poisoned patients hospitalized at Loghman Hakim Hospital between September 2010 and March 2011 were evaluated. Patients’ information including age, sex, time elapsed between the ingestion and presentation, and type of the BZ used were extracted from the patients' charts and recorded. ECGs on presentation to the emergency department (ED were evaluated and parameters such as PR interval, QRS duration, corrected QT, amplitude of S wave in lead I, height of R wave and R/S ratio in the lead aVR were also measured and recorded. Results: Oxazepam, chlordiazepoxide, lorazepam, alprazolam, diazepam, and clonazepam were ingested by 9 (3%, 13 (4.4%, 29 (9.9%, 105 (35.8%, 65 (22.2%, and 72 (24.6% patients, respectively. Mean PR interval was reported to be 0.16 ± 0.03 sec and PR interval of greater than 200 msec was detected in 12 (4.5% patients. Mean QRS duration was 0.07 ± 0.01sec and QRS≥120 msec was observed in 7 (2.6% cases. Conclusion: Diazepam is the only BZ that does not cause QRS widening and oxazepam is the only one not causing PR prolongation. It can be concluded that if a patient refers with a decreased level of consciousness and accompanying signs of BZ toxicity, QRS widening in ECG rules out diazepam, whereas PR prolongation rules out oxazepam toxicity.

  14. Noninvasive ventilation.

    Science.gov (United States)

    Rabatin, J T; Gay, P C

    1999-08-01

    Noninvasive ventilation refers to the delivery of assisted ventilatory support without the use of an endotracheal tube. Noninvasive positive pressure ventilation (NPPV) can be delivered by using a volume-controlled ventilator, a pressure-controlled ventilator, a bilevel positive airway pressure ventilator, or a continuous positive airway pressure device. During the past decade, there has been a resurgence in the use of noninvasive ventilation, fueled by advances in technology and clinical trials evaluating its use. Several manufacturers produce portable devices that are simple to operate. This review describes the equipment, techniques, and complications associated with NPPV and also the indications for both short-term and long-term applications. NPPV clearly represents an important addition to the techniques available to manage patients with respiratory failure. Future clinical trials evaluating its many clinical applications will help to define populations of patients most apt to benefit from this type of treatment.

  15. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the rabbit heart.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-01-01

    Ventricular arrhythmias represent one of leading causes for sudden cardiac death, a significant problem in public health. Noninvasive imaging of cardiac electric activities associated with ventricular arrhythmias plays an important role in better our understanding of the mechanisms and optimizing the treatment options. The present study aims to rigorously validate a novel three-dimensional (3-D) cardiac electrical imaging (3-DCEI) technique with the aid of 3-D intra-cardiac mapping during paced rhythm and ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in thirteen healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous norepinephrine (NE). The non-invasively imaged activation sequence correlated well with invasively measured counterparts, with a correlation coefficient of 0.72 and a relative error of 0.30 averaged over all paced beats and NE-induced PVCs and VT beats. The averaged distance from imaged site of initial activation to measured site determined from intra-cardiac mapping was ∼5mm. These promising results suggest that 3-DCEI is feasible to non-invasively localize the origins and image activation sequence of focal ventricular arrhythmias.

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, ...

  17. Magnetic resonance imaging of the normal and abnormal pulmonary hila

    International Nuclear Information System (INIS)

    Webb, W.R.; Gamsu, G.; Stark, D.D.; Moore, E.H.

    1984-01-01

    Magnetic resonance (MR) images of the hila were reviewed in 25 normal subjects and 12 patients with unilateral or bilateral hilar masses. On spin echo MR images in normal patients, collections of soft tissue large enough to be confused with an abnormally enlarged lymph node were seen in three locations. In patients with a hilar mass, the mass was differentiated from hilar vasculature more easily using MR than contrast-enhanced CT. However, because the spatial resolution of MR is inferior to that of CT, bronchi were difficult to evaulate using MR. Electrocardiographic-gated images showed better resolution of hilar structures but may not be necessary for large masses

  18. Study of noninvasive detection of latent fingerprints using UV laser

    Science.gov (United States)

    Li, Hong-xia; Cao, Jing; Niu, Jie-qing; Huang, Yun-gang; Mao, Lin-jie; Chen, Jing-rong

    2011-06-01

    Latent fingerprints present a considerable challenge in forensics, and noninvasive procedure that captures a digital image of the latent fingerprints is significant in the field of criminal investigation. The capability of photography technologies using 266nm UV Nd:YAG solid state laser as excitation light source to provide detailed images of unprocessed latent fingerprints is demonstrated. Unprocessed latent fingerprints were developed on various non-absorbent and absorbing substrates. According to the special absorption, reflection, scattering and fluorescence characterization of the various residues in fingerprints (fatty acid ester, protein, and carbosylic acid salts etc) to the UV light to weaken or eliminate the background disturbance and increase the brightness contrast of fingerprints with the background, and using 266nm UV laser as excitation light source, fresh and old latent fingerprints on the surface of four types of non-absorbent objects as magazine cover, glass, back of cellphone, wood desktop paintwork and two types of absorbing objects as manila envelope, notebook paper were noninvasive detected and appeared through reflection photography and fluorescence photography technologies, and the results meet the fingerprint identification requirements in forensic science.

  19. Telefetalcare: a first prototype of a wearable fetal electrocardiograph.

    Science.gov (United States)

    Fanelli, A; Signorini, M G; Ferrario, M; Perego, P; Piccini, L; Andreoni, G; Magenes, G

    2011-01-01

    Fetal heart rate monitoring is fundamental to infer information about fetal health state during pregnancy. The cardiotocography (CTG) is the most common antepartum monitoring technique. Abdominal ECG recording represents the most valuable alternative to cardiotocography, as it allows passive, non invasive and long term fetal monitoring. Unluckily fetal ECG has low SNR and needs to be extracted from abdominal recordings using ad hoc algorithms. This work describes a prototype of a wearable fetal ECG electrocardiograph. The system has flat band frequency response between 1-60 Hz and guarantees good signal quality. It was tested on pregnant women between the 30(th) and 34(th) gestational week. Several electrodes configurations were tested, in order to identify the best solution. Implementation of a simple algorithm for FECG extraction permitted the reliable detection of maternal and fetal QRS complexes. The system will allow continuative and deep screening of fetal heart rate, introducing the possibility of home fetal monitoring.

  20. How many electrocardiographic leads are required for exercise treadmill tests

    International Nuclear Information System (INIS)

    Miller, T.D.; Desser, K.B.; Lawson, M.

    1987-01-01

    Forty-four consecutive patients who had perfusion defects on thallium-201 scanning and positive exercise treadmill tests were prospectively studied. Thirty-eight (86%) subjects had diagnostic ST segment changes in lead V5, 37 (84%) in lead V4, and 44 (100%) in either lead V4, V5 or both. Thirty patients had ST segment changes in the inferior leads, 20 in lead aVR, and only four in lead I and/or aVL. All of these latter subjects had diagnostic ST segments in lead V4 and/or V5. It is concluded that: combined electrocardiographic leads V4 and V5 detect the vast majority of ischemic changes during exercise treadmill testing, regardless of the site of perfusion defects detected by thallium-201 scanning; and monitoring the inferior and lateral leads rarely provides more diagnostic information

  1. Novel axolotl cardiac function analysis method using magnetic resonance imaging

    NARCIS (Netherlands)

    Sanches, Pedro Gomes; Op 't Veld, Roel C.; de Graaf, Wolter; Strijkers, Gustav J.; Grüll, Holger

    2017-01-01

    The salamander axolotl is capable of complete regeneration of amputated heart tissue. However, non-invasive imaging tools for assessing its cardiac function were so far not employed. In this study, cardiac magnetic resonance imaging is introduced as a non-invasive technique to image heart function

  2. Novel axolotl cardiac function analysis method using magnetic resonance imaging

    NARCIS (Netherlands)

    Sanches, P.G.; Op ‘t Veld, R.C.; de Graaf, W.; Strijkers, G.J.; Grüll, H.

    2017-01-01

    The salamander axolotl is capable of complete regeneration of amputated heart tissue. However, non-invasive imaging tools for assessing its cardiac function were so far not employed. In this study, cardiac magnetic resonance imaging is introduced as a noninvasive technique to image heart function of

  3. Noninvasive IDH1 mutation estimation based on a quantitative radiomics approach for grade II glioma

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Jinhua [Fudan University, Department of Electronic Engineering, Shanghai (China); Computing and Computer-Assisted Intervention, Key Laboratory of Medical Imaging, Shanghai (China); Shi, Zhifeng; Chen, Liang; Mao, Ying [Fudan University, Department of Neurosurgery, Huashan Hospital, Shanghai (China); Lian, Yuxi; Li, Zeju; Liu, Tongtong; Gao, Yuan; Wang, Yuanyuan [Fudan University, Department of Electronic Engineering, Shanghai (China)

    2017-08-15

    The status of isocitrate dehydrogenase 1 (IDH1) is highly correlated with the development, treatment and prognosis of glioma. We explored a noninvasive method to reveal IDH1 status by using a quantitative radiomics approach for grade II glioma. A primary cohort consisting of 110 patients pathologically diagnosed with grade II glioma was retrospectively studied. The radiomics method developed in this paper includes image segmentation, high-throughput feature extraction, radiomics sequencing, feature selection and classification. Using the leave-one-out cross-validation (LOOCV) method, the classification result was compared with the real IDH1 situation from Sanger sequencing. Another independent validation cohort containing 30 patients was utilised to further test the method. A total of 671 high-throughput features were extracted and quantized. 110 features were selected by improved genetic algorithm. In LOOCV, the noninvasive IDH1 status estimation based on the proposed approach presented an estimation accuracy of 0.80, sensitivity of 0.83 and specificity of 0.74. Area under the receiver operating characteristic curve reached 0.86. Further validation on the independent cohort of 30 patients produced similar results. Radiomics is a potentially useful approach for estimating IDH1 mutation status noninvasively using conventional T2-FLAIR MRI images. The estimation accuracy could potentially be improved by using multiple imaging modalities. (orig.)

  4. Cardiac imaging using 256-detector row four-dimensional CT. Preliminary clinical report

    International Nuclear Information System (INIS)

    Kido, Teruhito; Kurata, Akira; Higashino, Hiroshi

    2007-01-01

    Along with the increase of detector rows on the z-axis and a faster gantry rotation speed, the spatial and temporal resolutions of the multislice computed tomography (CT) have been improved for noninvasive coronary artery imaging. We investigated the feasibility of the second specification prototype 256-detector row four-dimensional CT for assessing coronary artery and cardiac function. The subjects were five patients with coronary artery disease. Contrast medium (40-60 ml) was intravenously administered at the rate of 3-4 ml/s. The patient's whole heart was scanned for 1.5 s to cover at least one cardiac cycle during breathholding without electrocardiographic gating. Parameters used were 0.5 mm slice thickness, 0.5 s/rotation, 120 Kv, and 350 mA, with a half-scan reconstruction algorithm (temporal resolution 250 ms). Twenty-six transaxial datasets were reconstructed at intervals of 50 ms. The assessability of the coronary arteries in American Heart Association (AHA) segments 1, 2, 3, 5, 6, 7, 9, and 11 was visually evaluated, resulting in 29 of 32 (90.9%) segments being assessable. Functional assessment was also performed using animated movies without banding artifacts in all cases. The 256-detector row four-dimensional CT can assess the coronary artery and cardiac function using data during 1.5 s without banding artifacts. (author)

  5. Noninvasive detection of hepatic lipidosis in dairy cows with calibrated ultrasonographic image analysis.

    Science.gov (United States)

    Starke, A; Haudum, A; Weijers, G; Herzog, K; Wohlsein, P; Beyerbach, M; de Korte, C L; Thijssen, J M; Rehage, J

    2010-07-01

    =100mg of TAG/g of FW), and 0.97 (or=100mg of TAG/g of FW). The CAUS methodology and software for digitally analyzing liver ultrasonographic images is considered feasible for noninvasive screening of fatty liver in dairy herd health programs. Using the single parameter linear regression equation might be ideal for practical applications. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  6. Analysis of the Sensitivity and Specificity of Noninvasive Imaging Tests for the Diagnosis of Renal Artery Stenosis

    International Nuclear Information System (INIS)

    Borelli, Flavio Antonio de Oliveira; Pinto, Ibraim M. F.; Amodeo, Celso; Smanio, Paola E. P.; Kambara, Antonio M.; Petisco, Ana Claudia G.; Moreira, Samuel M.; Paiva, Ricardo Calil; Lopes, Hugo Belotti; Sousa, Amanda G. M. R.

    2013-01-01

    Aging and atherosclerosis are related to renovascular hypertension in elderly individuals. Regardless of comorbidities, renal artery stenosis is itself an important cause of cardiovascular morbidity and mortality. To define the sensitivity, specificity, positive predictive value, and negative predictive value of noninvasive imaging tests used in the diagnosis of renal artery stenosis. In a group of 61 patients recruited, 122 arteries were analized, thus permitting the definition of sensitivity, specificity, and the relative contribution of each imaging study performed (Doppler, scintigraphy and computed tomographic angiography in comparison to renal arteriography). The mean age was 65.43 years (standard deviation: 8.7). Of the variables related to the study population that were compared to arteriography, two correlated with renal artery stenosis, renal dysfunction and triglycerides. The median glomerular filtration rate was 52.8 mL/min/m 2 . Doppler showed sensitivity of 82.90%, specificity of 70%, a positive predictive value of 85% and negative predictive value of 66.70%. For tomography, sensitivity was 66.70%, specificity 80%, positive predictive value 87.50% and negative predictive value 55.20%. With these findings, we could identify the imaging tests that best detected stenosis. Tomography and Doppler showed good quality and efficacy in the diagnosis of renal artery stenosis, with Doppler having the advantage of not requiring the use of contrast medium for the assessment of a disease that is common in diabetics and is associated with renal dysfunction and severe left ventricular dysfunction

  7. Analysis of the Sensitivity and Specificity of Noninvasive Imaging Tests for the Diagnosis of Renal Artery Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Borelli, Flavio Antonio de Oliveira, E-mail: fborelli@cardiol.br; Pinto, Ibraim M. F.; Amodeo, Celso; Smanio, Paola E. P.; Kambara, Antonio M.; Petisco, Ana Claudia G.; Moreira, Samuel M.; Paiva, Ricardo Calil; Lopes, Hugo Belotti; Sousa, Amanda G. M. R. [Instituto Dante Pazzanese de Cardiologia, São Paulo, SP (Brazil)

    2013-11-15

    Aging and atherosclerosis are related to renovascular hypertension in elderly individuals. Regardless of comorbidities, renal artery stenosis is itself an important cause of cardiovascular morbidity and mortality. To define the sensitivity, specificity, positive predictive value, and negative predictive value of noninvasive imaging tests used in the diagnosis of renal artery stenosis. In a group of 61 patients recruited, 122 arteries were analized, thus permitting the definition of sensitivity, specificity, and the relative contribution of each imaging study performed (Doppler, scintigraphy and computed tomographic angiography in comparison to renal arteriography). The mean age was 65.43 years (standard deviation: 8.7). Of the variables related to the study population that were compared to arteriography, two correlated with renal artery stenosis, renal dysfunction and triglycerides. The median glomerular filtration rate was 52.8 mL/min/m{sup 2}. Doppler showed sensitivity of 82.90%, specificity of 70%, a positive predictive value of 85% and negative predictive value of 66.70%. For tomography, sensitivity was 66.70%, specificity 80%, positive predictive value 87.50% and negative predictive value 55.20%. With these findings, we could identify the imaging tests that best detected stenosis. Tomography and Doppler showed good quality and efficacy in the diagnosis of renal artery stenosis, with Doppler having the advantage of not requiring the use of contrast medium for the assessment of a disease that is common in diabetics and is associated with renal dysfunction and severe left ventricular dysfunction.

  8. The prevalence of the electrocardiographic J wave in the Petit Basset Griffon Vendéen compared to 10 different dog breeds

    DEFF Research Database (Denmark)

    Rudling, E. H.; Schlamowitz, Sarah; Pipper, Christian Bressen

    2016-01-01

    INTRODUCTION: To investigate the prevalence and amplitudes of the electrocardiographic J wave in the Petit Basset Griffon Vendéen compared to 10 other dog breeds. ANIMALS: Electrocardiograms from 206 healthy dogs representing 11 dog breeds were included in the study. Besides Petit Basset Griffon...

  9. Non-Invasive and Minimally Invasive Imaging Evaluation of CSF Rhinorrhoea – a Retrospective Study with Review of Literature

    International Nuclear Information System (INIS)

    Vimala, Leena Robinson; Jasper, Anitha; Irodi, Aparna

    2016-01-01

    Localization of a cerebrospinal fluid [CSF] fistula is a diagnostic challenge. The choice of an optimal imaging technique is necessary to locate the site of CSF leak which is required for surgical/endoscopic repair of the CSF fistula. Retrospective analysis of imaging was performed in 33 patients who presented with symptoms suggestive of CSF rhinorrhoea over a period of two years. Either a bone defect on high resolution CT [HRCT] or CSF column extending extracranially from the subarachnoid space with or without brain/ meningeal herniation on magnetic resonance [MR] cisternography was considered positive for CSF leak. The MR imaging technique included 1-mm heavily T2-weighted [TR 2000 ms; TE-200 ms] fast spin echo study in coronal and sagittal planes. HRCT sections involved 0.625 to 0.8-mm sections in the coronal plane, with or without axial planes, through the paranasal sinuses, reconstructed in a sharp algorithm and acquired with the patient in prone position. Imaging findings were compared with endoscopic findings, being the gold standard for the assessment of CSF rhinorrhea. A total of 25 patients had a combination of HRCT and MR cisternography. The sensitivity, specificity, positive predictive value [PPV] and negative predictive value [NPV] of both MR cisternography and HRCT together were 93%, 100%, 100% and 50% respectively. Two patients underwent only MR cisternography, 5 patients underwent only HRCT and one patient underwent HRCT, MR cisternography and CT cisternography. Though PPV was 100% in the groups with HRCT alone, MR cisternography alone and combined CT cisternography, HRCT and MR cisternography, the results were not statistically significant as the number of patients in those groups was lower. Combination of MR cisternography and HRCT appears to be complementary, accurate and non-invasive and should be considered as optimal imaging modality for pre-op imaging in the evaluation of CSF rhinorrhoea

  10. Validation of a non-invasive arterial monitor GATE model for PET

    Energy Technology Data Exchange (ETDEWEB)

    Giansiracusa, P.J., E-mail: pgia@student.unimelb.edu.au [School of Physics, The University of Melbourne, Parkville (Australia); Peake, D.J. [DETECT Australia, Bundoora (Australia); Sobott, B.A. [School of Physics, The University of Melbourne, Parkville (Australia); O' Keefe, G. [The Austin PET Centre, Austin Hospital, Heidelberg (Australia); Rassool, R.P. [School of Physics, The University of Melbourne, Parkville (Australia)

    2014-02-11

    The Non-Invasive Arterial Monitor (NIAM3) is an SiPM based detector system designed for calibrating Positron-Emission Tomography (PET) images without invasive blood sampling. By imaging the radial and ulnar arteries in the wrist directly with a custom built PET system the resultant PET images can be calibrated. An integral step in the development of a complex detector system is the creation of a model which accurately reflects the physical reality being studied. This paper describes the development of a simulation for NIAM which shows good agreement between the model and physical detector setup.

  11. Molecular MR Imaging Probes

    OpenAIRE

    MAHMOOD, UMAR; JOSEPHSON, LEE

    2005-01-01

    Magnetic resonance imaging (MRI) has been successfully applied to many of the applications of molecular imaging. This review discusses by example some of the advances in areas such as multimodality MR-optical agents, receptor imaging, apoptosis imaging, angiogenesis imaging, noninvasive cell tracking, and imaging of MR marker genes.

  12. Medical imaging

    CERN Document Server

    Townsend, David W

    1996-01-01

    Since the introduction of the X-ray scanner into radiology almost 25 years ago, non-invasive imaging has become firmly established as an essential tool in the diagnosis of disease. Fully three-dimensional imaging of internal organs is now possible, b and for studies which explore the functional status of the body. Powerful techniques to correlate anatomy and function are available, and scanners which combine anatomical and functional imaging in a single device are under development. Such techniques have been made possible through r ecent technological and mathematical advances. This series of lectures will review both the physical basis of medical imaging techniques using X-rays, gamma and positron emitting radiosiotopes, and nuclear magnetic resonance, and the mathematical methods used to reconstruct three-dimentional distributions from projection data. The lectures will trace the development of medical imaging from simple radiographs to the present-day non-invasive measurement of in vivo biochemistry. They ...

  13. Noninvasive Ventilation in Premature Neonates.

    Science.gov (United States)

    Flanagan, Keri Ann

    2016-04-01

    The use of noninvasive ventilation is a constantly evolving treatment option for respiratory disease in the premature infant. The goals of these noninvasive ventilation techniques are to improve gas exchange in the premature infant's lungs and to minimize the need for intubation and invasive mechanical ventilation. The goals of this article are to consider various uses of nasal interfaces, discuss skin care and developmental positioning concerns faced by the bedside nurse, and discuss the medical management aimed to reduce morbidity and mortality. This article explores the nursing role, the advances in medical strategies for noninvasive ventilation, and the team approach to noninvasive ventilation use in this population. Search strategy included a literature review on medical databases, such as EBSCOhost, CINAHL, PubMed, and NeoReviews. Innovative products, nursing research on developmental positioning and skin care, and advanced medical management have led to better and safer outcomes for premature infants requiring noninvasive ventilation. The medical focus of avoiding long-term mechanical ventilation would not be possible without the technology to provide noninvasive ventilation to these premature infants and the watchful eye of the nurse in terms of careful positioning, preventing skin breakdown and facial scarring, and a proper seal to maximize ventilation accuracy. This article encourages nursing-based research to quantify some of the knowledge about skin care and positioning as well as research into most appropriate uses for noninvasive ventilation devices.

  14. Prophylactic accessory-pathway ablation in asymptomatic patients with a Wolff-Parkinson-White electrocardiographic pattern.

    Science.gov (United States)

    Ozenc, S; Iscen, S; Kibrisli, E; Tok, D; Parlak, A; Altinel, O; Altinel, S

    2014-01-01

    The optimal approach is controversial in asymptomatic patients who are coincidentally found to have evidence of an accessory pathway (AP) on an ECG. The risk of sudden cardiac death (SCD) is low, and the risk of developing symptoms also appears to be low, although a wide range of incidences have been reported. In our trial, we tested the hypothesis that if prophylactic accessory-pathway ablation performed at the time of the initial electrophysiological testing would improve the long-term outcome in asymptomatic patients with a Wolff-Parkinson-White electrocardiographic pattern. Recruitment of patients began on February 1, 2004, and ended on February 5, 2009. All 110 asymptomatic patients were hospitalized and underwent electrophysiological testing the same day to assess the inducibility of atrioventricular reciprocating tachycardia. The anterograde effective refractory period of the accessory pathway was defined as the longest coupling interval at which anterograde block in the bypass tract was observed. For the statistical analysis, the statistical software SPSS version 15.0 for Windows (SPSS Inc., Chicago, IL, USA). Of 110 asymptomatic patients with a Wolff-Parkinson-White electrocardiographic pattern, 80 patients were ablated. Ablation group consisted of these patients. Control group consisted of remaining 30 and were divided into two groups according to the anterograde effective refractory period of the accessory pathway. There was no significant difference between three groups in terms of arrhythmic events (p: 0.58). Asymptomatic patients with the Wolff-Parkinson-White syndrome do not require prophylactic ablation, since they remain asymptomatic for many years.

  15. Non-invasive diagnosis of isolated chylopericardium using precordial pericardial imaging after oral administration of 131I-triolein

    International Nuclear Information System (INIS)

    Fujiseki, Yoshiki; Katsura, Tadahiko; Goto, Masakatsu; Kawanishi, Katsuyuki

    1982-01-01

    Chylopericardium is a rare disease and affects both sexes equally from neonate to adult. Usually, there are abnormal connections between the pericardial cavity and thoracic lymphatic systems. These connections are detected by (1) recovery of orally administered Sudan III from pericardial fluid, (2) evidence of radioactivity in the pericardial fluid by paracentesis after oral administration of 131 I-labeled triolein, and (3) lymphangiography. However, these method are technically difficult and invasive, thus sometimes dangerous for children. We employed precordial pericardial imaging after oral administration of 131 I-labeled triolein on a 9-year-old Japanese girl wth isolated chylopericardium before and after surgery. Abnormal connections and the back-ward flow to the pulmonary lymphatics were demonstrated by this method. This is an easy, non-invasive, reliable and safe method for detecting the abnormal connections of pericardial and lymphatic systems in children with chylopericardium. (author)

  16. Characteristics and significance of ischemia detected by ambulatory electrocardiographic monitoring

    International Nuclear Information System (INIS)

    Nabel, E.G.; Rocco, M.B.; Selwyn, A.B.

    1987-01-01

    Ambulatory electrocardiographic (ECG) monitoring of ischemia in patients with coronary artery disease (CAD) provides a new technique for the assessment of ischemic activity and the evaluation of therapies outside of the hospital. Numerous studies have demonstrated that the majority of patients with CAD have episodes of symptomatic and asymptomatic ST segment depression during routine daily activities. Rubidium-82 positron-emission tomographic studies have provided evidence for decreased myocardial perfusion during these episodes of ST segment depression. The prognostic importance of asymptomatic ischemia has been shown in patients with unstable angina to be a marker for early unfavorable cardiac events. Preliminary results suggest a poorer outcome for those patients with chronic stable angina who show episodes of ischemia as well. Ambulatory monitoring studies suggest that total ischemic activity may be underestimated by conventional testing. Whether all ischemic activity detected by ambulatory monitoring requires treatment awaits further study. 69 references

  17. A New Quantitative Method for the Non-Invasive Documentation of Morphological Damage in Paintings Using RTI Surface Normals

    Directory of Open Access Journals (Sweden)

    Marcello Manfredi

    2014-07-01

    Full Text Available In this paper we propose a reliable surface imaging method for the non-invasive detection of morphological changes in paintings. Usually, the evaluation and quantification of changes and defects results mostly from an optical and subjective assessment, through the comparison of the previous and subsequent state of conservation and by means of condition reports. Using quantitative Reflectance Transformation Imaging (RTI we obtain detailed information on the geometry and morphology of the painting surface with a fast, precise and non-invasive method. Accurate and quantitative measurements of deterioration were acquired after the painting experienced artificial damage. Morphological changes were documented using normal vector images while the intensity map succeeded in highlighting, quantifying and describing the physical changes. We estimate that the technique can detect a morphological damage slightly smaller than 0.3 mm, which would be difficult to detect with the eye, considering the painting size. This non-invasive tool could be very useful, for example, to examine paintings and artwork before they travel on loan or during a restoration. The method lends itself to automated analysis of large images and datasets. Quantitative RTI thus eases the transition of extending human vision into the realm of measuring change over time.

  18. Exclusion and diagnosis of pulmonary embolism by a rapid ELISA D-dimer test and noninvasive imaging techniques within the context of a clinical model.

    Science.gov (United States)

    Michiels, J J; Pattynama, P M

    2000-01-01

    A negative rapid ELISA D-dimer test alone in out-patients with a low to moderate clinical probability (CP) on pulmonary embolism (PE) is predicted to safely exclude pulmonary embolism. The combination of a negative rapid ELISA D-dimer test and a low to moderate CP on PE followed by compression ultrasonography (CUS) for the detection of deep vein thrombosis (DVT) is safe and cost-effective as it reduces the need for noninvasive imaging techniques to about 50% to 60% of outpatients with suspected PE. A high probability ventilation-perfusion (VP) scan or a positive spiral CT consistent with PE and the detection of DVT by CUS are currently considered to be clear indications for anticoagulant treatment. Subsequent pulmonary angiography (PA) is the gold standard diagnostic strategy to exclude or diagnose PE in suspected outpatients with a negative CUS, a positive rapid ELISA D-dimer test, and a nondiagnostic VP scan or negative spiral CT to prevent overtreatment with anticoagulants. However, the willingness of clinicians and the availability of resources to perform PA is restricted, a fact that has provided an impetus for clinical investigators to search for alternative noninvasive strategies to exclude or detect venous thromboembolism (VTE). Serial CUS testing for the detection of DVT in patients with a low to moderate CP on PE and a nondiagnostic VP scan or negative spiral CT is predicted to be safe and will reduce the need for PA to less than 10% or even less than 5%. This noninvasive serial CUS strategy restricts the need for invasive PA to a minor group of patients (spiral CT and a high CP on PE. Prospective evaluations are warranted to implement and to validate the advantages and the disadvantages of the various combinations of noninvasive strategies and to compare serial CUS testing versus PA in randomized clinical management studies of outpatients with suspected pulmonary embolism.

  19. On the feasibility of self-mixing interferometer sensing for detection of the surface electrocardiographic signal using a customized electro-optic phase modulator

    International Nuclear Information System (INIS)

    Bakar, A Ashrif A; Lim, Yah Leng; Wilson, Stephen J; Fuentes, Miguel; Bertling, Karl; Taimre, Thomas; Rakić, Aleksandar D; Bosch, Thierry

    2013-01-01

    Optical sensing offers an attractive option for detection of surface biopotentials in human subjects where electromagnetically noisy environments exist or safety requirements dictate a high degree of galvanic isolation. Such circumstances may be found in modern magnetic resonance imaging systems for example. The low signal amplitude and high source impedance of typical biopotentials have made optical transduction an uncommon sensing approach. We propose a solution consisting of an electro-optic phase modulator as a transducer, coupled to a vertical-cavity surface-emitting laser and the self-mixing signal detected via a photodiode. This configuration is physically evaluated with respect to synthesized surface electrocardiographic (EKG) signals of varying amplitudes and using differing optical feedback regimes. Optically detected EKG signals using strong optical feedback show the feasibility of this approach and indicate directions for optimization of the electro-optic transducer for improved signal-to-noise ratios. This may provide a new means of biopotential detection suited for environments characterized by harsh electromagnetic interference. (paper)

  20. Superparamagnetic iron oxide nanoparticles function as a long-term, multi-modal imaging label for non-invasive tracking of implanted progenitor cells.

    Directory of Open Access Journals (Sweden)

    Christina A Pacak

    Full Text Available The purpose of this study was to determine the ability of superparamagnetic iron oxide (SPIO nanoparticles to function as a long-term tracking label for multi-modal imaging of implanted engineered tissues containing muscle-derived progenitor cells using magnetic resonance imaging (MRI and X-ray micro-computed tomography (μCT. SPIO-labeled primary myoblasts were embedded in fibrin sealant and imaged to obtain intensity data by MRI or radio-opacity information by μCT. Each imaging modality displayed a detection gradient that matched increasing SPIO concentrations. Labeled cells were then incorporated in fibrin sealant, injected into the atrioventricular groove of rat hearts, and imaged in vivo and ex vivo for up to 1 year. Transplanted cells were identified in intact animals and isolated hearts using both imaging modalities. MRI was better able to detect minuscule amounts of SPIO nanoparticles, while μCT more precisely identified the location of heavily-labeled cells. Histological analyses confirmed that iron oxide particles were confined to viable, skeletal muscle-derived cells in the implant at the expected location based on MRI and μCT. These analyses showed no evidence of phagocytosis of labeled cells by macrophages or release of nanoparticles from transplanted cells. In conclusion, we established that SPIO nanoparticles function as a sensitive and specific long-term label for MRI and μCT, respectively. Our findings will enable investigators interested in regenerative therapies to non-invasively and serially acquire complementary, high-resolution images of transplanted cells for one year using a single label.

  1. Imaging Atherosclerosis with Hybrid Positron Emission Tomography/Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Ripa, Rasmus Sejersten; Kjær, Andreas

    2015-01-01

    Noninvasive imaging of atherosclerosis could potentially move patient management towards individualized triage, treatment, and followup. The newly introduced combined positron emission tomography (PET) and magnetic resonance imaging (MRI) system could emerge as a key player in this context. Both...

  2. Non-invasive monitoring of pulmonary artery pressure from timing information by EIT: experimental evaluation during induced hypoxia.

    Science.gov (United States)

    Proença, Martin; Braun, Fabian; Solà, Josep; Adler, Andy; Lemay, Mathieu; Thiran, Jean-Philippe; Rimoldi, Stefano F

    2016-06-01

    Monitoring of pulmonary artery pressure (PAP) in pulmonary hypertensive patients is currently limited to invasive solutions. We investigate a novel non-invasive approach for continuous monitoring of PAP, based on electrical impedance tomography (EIT), a safe, low-cost and non-invasive imaging technology. EIT recordings were performed in three healthy subjects undergoing hypoxia-induced PAP variations. The pulmonary pulse arrival time (PAT), a timing parameter physiologically linked to the PAP, was automatically calculated from the EIT signals. Values were compared to systolic PAP values from Doppler echocardiography, and yielded strong correlation scores ([Formula: see text]) for all three subjects. Results suggest the feasibility of non-invasive, unsupervised monitoring of PAP.

  3. Reflectance confocal microscopy: non-invasive distinction between actinic keratosis and squamous cell carcinoma

    NARCIS (Netherlands)

    Peppelman, M.; Nguyen, K.P.; Hoogedoorn, L.; Erp, P.E.J. van; Gerritsen, M.J.P.

    2015-01-01

    BACKGROUND: Early recognition of squamous cell carcinoma (SCC) is difficult. Non-invasive reflectance confocal microscopic (RCM) imaging of the skin is a promising diagnostic technique. Although several RCM features for SCC and AK have been described, it is not determined whether RCM has the ability

  4. Quantification of brain perfusion SPECT with N-isopropyl-p-iodoamphetamine using noninvasive microsphere method. Estimation of arterial input by dynamic imaging

    International Nuclear Information System (INIS)

    Yonekura, Yoshiharu; Sugihara, Hideki; Taniguchi, Yoshimitsu; Aoki, Etsuo; Furuichi, Kenji; Miyazaki, Yoshiharu.

    1997-01-01

    We have developed a noninvasive method to quantify brain perfusion SPECT with 123 I-N-isopropyl-p-iodoamphetamine (IMP) using serial dynamic planar imaging of the initial transit phase. The method is based on the microsphere model, but does not require arterial sampling. Serial dynamic planar imaging was performed for 6 min after the bolus injection of IMP (167 MBq in 1.5 ml), followed by additional planar imaging at 20 min and SPECT scan thereafter. The total arterial input to the brain during the initial 5 min after injection was estimated by the injected dose, with the correction of the lung retention, divided by cardiac output (CO). CO was estimated from the initial transit of IMP in the right heart. Cardiac output index (COI), obtained from the integral of the first transit of IMP in the right heart divided by the injected dose, was calibrated by CO measured by Doppler ultrasonography. Regional cerebral blood flow (rCBF) obtained by this method in normal subjects was acceptable. However, the results may be influenced by the injection technique, and careful attention should be considered for clinical application of this method. (author)

  5. Electrocardiographic Precordial ST‐Segment Deviations and the Risk of Cardiovascular Death

    DEFF Research Database (Denmark)

    Rasmussen, Peter Vibe; Nielsen, Jonas Bille; Pietersen, Adrian

    2014-01-01

    BACKGROUND: We sought to perform a study assessing the association between electrocardiographic ST-segment deviations and cardiovascular death (CVD), in relation to sex and age (≥ and disease. METHODS AND RESULTS: Using...... computerized analysis of ECGs from 285 194 persons, we evaluated the association between precordial ST-segment deviations and the risk of CVD. All data on medication, comorbidity, and outcomes were retrieved from Danish registries. After a median follow-up period of 5.8 years, there were 6679 cardiovascular...... deaths. Increasing ST-depression was associated with an increased risk of CVD in almost all of the precordial leads, with the most robust association seen in lead V5 to V6. ST-elevations in lead V2 to V6 were associated with increased risk of CVD in young women, but not in men. However, ST...

  6. The Diagnostic Agreement of Original and Faxed Copies of Electrocardiograms

    Directory of Open Access Journals (Sweden)

    Sadrihe Hajesmaeel-Gohari

    2013-02-01

    Full Text Available Background: General practitioners working in remote and rural areas sometimes need consultation with cardiologists. One practical and cost-effective way is transmission of patients’ electrocardiographic images via ordinary fax machine to the cardiologists, but there is an important question that how much agreement exists between the diagnoses made by reading an original electrocardiogram and its copy transmitted via fax.Materials and Methods: In this cross-sectional study, 60 original electrocardiographic images were given to cardiologists for diagnosis. In the next step those electrocardiographic images were faxed to the hospital through a simple cheap fax machine, one month later the same cardiologist was asked to put his diagnosis on the copied versions of electrocardiographs, and the results were compared. Results: In 59 studied cases, the two method of diagnoses were exactly the same and only in one case the diagnoses were different. Therefore, Kappa agreement coefficient was calculated as 96%.Conclusion: According to the results of this study, general practitioners working in deprived areas can be certainly recommended to send patients’ electrocardiographic images to the cardiologists via fax in the case of needing consultation.

  7. Respiration-induced movement correlation for synchronous noninvasive renal cancer surgery.

    Science.gov (United States)

    Abhilash, Rakkunedeth H; Chauhan, Sunita

    2012-07-01

    Noninvasive surgery (NIS), such as high-intensity focused ultrasound (HIFU)-based ablation or radiosurgery, is used for treating tumors and cancers in various parts of the body. The soft tissue targets (usually organs) deform and move as a result of physiological processes such as respiration. Moreover, other deformations induced during surgery by changes in patient position, changes in physical properties caused by repeated exposures and uncertainties resulting from cavitation also occur. In this paper, we present a correlation-based movement prediction technique to address respiration-induced movement of the urological organs while targeting through extracorporeal trans-abdominal route access. Among other organs, kidneys are worst affected during respiratory cycles, with significant three-dimensional displacements observed on the order of 20 mm. Remote access to renal targets such as renal carcinomas and cysts during noninvasive surgery, therefore, requires a tightly controlled real-time motion tracking and quantitative estimate for compensation routine to synchronize the energy source(s) for precise energy delivery to the intended regions. The correlation model finds a mapping between the movement patterns of external skin markers placed on the abdominal access window and the internal movement of the targeted kidney. The coarse estimate of position is then fine-tuned using the Adaptive Neuro-Fuzzy Inference System (ANFIS), thereby achieving a nonlinear mapping. The technical issues involved in this tracking scheme are threefold: the model must have sufficient accuracy in mapping the movement pattern; there must be an image-based tracking scheme to provide the organ position within allowable system latency; and the processing delay resulting from modeling and tracking must be within the achievable prediction horizon to accommodate the latency in the therapeutic delivery system. The concept was tested on ultrasound image sequences collected from 20 healthy

  8. Invasive v non-invasive assessment of the carotid arteries prior to trans-sphenoidal surgery

    International Nuclear Information System (INIS)

    Macpherson, P.; Teasdale, E.; Hadley, D.M.; Teasdale, G.

    1987-01-01

    Imaging studies in 47 patients who were to undergo trans-sphenoidal surgery were analysed with reference to the vascular structures in the parasellar region. The results of cavernous sinography, dynamic contrast enhanced computed tomography (CT) and magnetic resonance imaging (MRI) showed good correlation with each other and with the appearances found at operation. CT and MRI, both non-invasive investigations, are therefore reliable preliminary screening methods for identifying the small proportion of patients on whom other imaging techniques need to be performed. (orig.)

  9. Dose modeling of noninvasive image-guided breast brachytherapy in comparison to electron beam boost and three-dimensional conformal accelerated partial breast irradiation.

    Science.gov (United States)

    Sioshansi, Shirin; Rivard, Mark J; Hiatt, Jessica R; Hurley, Amanda A; Lee, Yoojin; Wazer, David E

    2011-06-01

    To perform dose modeling of a noninvasive image-guided breast brachytherapy (NIIGBB) for comparison to electrons and 3DCRT. The novel technology used in this study is a mammography-based, noninvasive breast brachytherapy system whereby the treatment applicators are centered on the planning target volume (PTV) to direct (192)Ir emissions along orthogonal axes. To date, three-dimensional dose modeling of NIIGBB has not been possible because of the limitations of conventional treatment planning systems (TPS) to model variable tissue deformation associated with breast compression. In this study, the TPS was adapted such that the NIIGBB dose distributions were modeled as a virtual point source. This dose calculation technique was applied to CT data from 8 patients imaged with the breast compressed between parallel plates in the cranial-caudal and medial-lateral axes. A dose-volume comparison was performed to simulated electron boost and 3DCRT APBI. The NIIGBB PTV was significantly reduced as compared with both electrons and 3DCRT. Electron boost plans had a lower D(min) than the NIIGBB technique but higher V(100), D(90), and D(50). With regard to PTV coverage for APBI, the only significant differences were minimally higher D(90), D(100), V(80), and V(90), with 3DCRT and D(max) with NIIGBB. The NIIGBB technique, as compared with electrons and 3D-CRT, achieved a lower maximum dose to skin (60% and 10%, respectively) and chest wall/lung (70-90%). NIIGBB achieves a PTV that is smaller than electron beam and 3DCRT techniques. This results in significant normal tissue sparing while maintaining dosimetric benchmarks to the target tissue. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Multiparametric Functional MRI: Non-Invasive Imaging of Inflammation and Edema Formation after Kidney Transplantation in Mice.

    Directory of Open Access Journals (Sweden)

    Katja Hueper

    Full Text Available Kidney transplantation (ktx in mice is used to learn about rejection and to develop new treatment strategies. Past studies have mainly been based on histological or molecular biological methods. Imaging techniques to monitor allograft pathology have rarely been used.Here we investigated mice after isogenic and allogenic ktx over time with functional MRI with diffusion-weighted imaging (DWI and mapping of T2-relaxation time (T2-mapping to assess graft inflammation and edema formation. To characterize graft pathology, we used PAS-staining, counted CD3-positive T-lymphocytes, analyzed leukocytes by means flow cytometry.DWI revealed progressive restriction of diffusion of water molecules in allogenic kidney grafts. This was paralleled by enhanced infiltration of the kidney by inflammatory cells. Changes in tissue diffusion were not seen following isogenic ktx. T2-times in renal cortex were increased after both isogenic and allogenic transplantation, consistent with tissue edema due to ischemic injury following prolonged cold ischemia time of 60 minutes. Lack of T2 increase in the inner stripe of the inner medulla in allogenic kidney grafts matched loss of tubular autofluorescence and may result from rejection-driven reductions in tubular water content due to tubular dysfunction and renal functional impairment.Functional MRI is a valuable non-invasive technique for monitoring inflammation, tissue edema and tubular function. It permits on to differentiate between acute rejection and ischemic renal injury in a mouse model of ktx.

  11. Noninvasive Urodynamic Evaluation

    Directory of Open Access Journals (Sweden)

    Carlos Arturo Levi D'Ancona

    2012-09-01

    Full Text Available The longevity of the world's population is increasing, and among male patients, complaints of lower urinary tract symptoms (LUTS are growing. Testing to diagnose LUTS and to differentiate between the various causes should be quick, easy, cheap, specific, not too bothersome for the patient, and noninvasive or minimally so. Urodynamic evaluation is the gold standard for diagnosing bladder outlet obstruction (BOO but presents some inconveniences such as embarrassment, pain, and dysuria; furthermore, 19% of cases experience urinary retention, macroscopic hematuria, or urinary tract infection. A greater number of resources in the diagnostic armamentarium could increase the opportunity for selecting less invasive tests. A number of groups have risen to this challenge and have formulated and developed ideas and technologies to improve noninvasive methods to diagnosis BOO. These techniques start with flowmetry, an increase in the interest of ultrasound, and finally the performance of urodynamic evaluation without a urethral catheter. Flowmetry is not sufficient for confirming a diagnosis of BOO. Ultrasound of the prostate and the bladder can help to assess BOO noninvasively in all men and can be useful for evaluating the value of BOO at assessment and during treatment of benign prostatic hyperplasia patients in the future. The great advantages of noninvasive urodynamics are as follows: minimal discomfort, minimal risk of urinary tract infection, and low cost. This method can be repeated many times, permitting the evaluation of obstruction during clinical treatment. A urethral connector should be used to diagnose BOO, in evaluation for surgery, and in screening for treatment. In the future, noninvasive urodynamics can be used to identify patients with BOO to initiate early medical treatment and evaluate the results. This approach permits the possibility of performing surgery before detrusor damage occurs.

  12. Sodium Iodide Symporter PET and BLI Noninvasively Reveal Mesoangioblast Survival in Dystrophic Mice

    Directory of Open Access Journals (Sweden)

    Bryan Holvoet

    2015-12-01

    Full Text Available Muscular dystrophies are a heterogeneous group of myopathies, characterized by muscle weakness and degeneration, without curative treatment. Mesoangioblasts (MABs have been proposed as a potential regenerative therapy. To improve our understanding of the in vivo behavior of MABs and the effect of different immunosuppressive therapies, like cyclosporine A or co-stimulation-adhesion blockade therapy, on cell survival noninvasive cell monitoring is required. Therefore, cells were transduced with a lentiviral vector encoding firefly luciferase (Fluc and the human sodium iodide transporter (hNIS to allow cell monitoring via bioluminescence imaging (BLI and small-animal positron emission tomography (PET. Non-H2 matched mMABs were injected in the femoral artery of dystrophic mice and were clearly visible via small-animal PET and BLI. Based on noninvasive imaging data, we were able to show that co-stim was clearly superior to CsA in reducing cell rejection and this was mediated via a reduction in cytotoxic T cells and upregulation of regulatory T cells.

  13. Molecular imaging in oncology

    International Nuclear Information System (INIS)

    Weber, W.A.

    2007-01-01

    Molecular imaging is generally defined as noninvasive and quantitative imaging of targeted macromolecules and biological processes in living organisms. A characteristic of molecular imaging is the ability to perform repeated studies and assess changes in biological processes over time. Thus molecular imaging lends itself well for monitoring the effectiveness of tumor therapy. In animal models a variety of techniques can be used for molecular imaging. These include optical imaging (bioluminescence and fluorescence imaging), magnetic resonance imaging (MRI) and nuclear medicine techniques. In the clinical setting, however, nuclear medicine techniques predominate, because so far only radioactive tracers provide the necessary sensitivity to study expression and function of macromolecules non-invasively in patients. Nuclear medicine techniques allows to study a variety of biological processes in patients. These include the expression of various receptors (estrogen, androgen, somatostatin receptors and integrins). In addition, tracers are available to study tumor cell proliferation and hypoxia. The by far most commonly used molecular imaging technique in oncology is, however, positron emission tomography (PET) with the glucose analog [ 18 F]fluorodeoxyglucose (FDG-PET). FDG-PET permits non-invasive quantitative assessment of the accelerated exogenous glucose use of malignant tumors. Numerous studies have now shown that reduction of tumor FDG-uptake during therapy allows early prediction of tumor response and patient survival. Clinical studies are currently underway to determine whether FDG-PET can be used to individualize tumor therapy by signaling early in the course of therapy the need for therapeutic adjustments in patients with likely non-responding tumors. (orig.)

  14. Phase analysis of regional and global ventricular contraction patterns in Wolff-Parkinson-White syndrome. Assessment by radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, Tokuji; Koyama, Takao; Ichikawa, Takehiko and others

    1989-04-01

    Multigated blood pool scintigraphy was performed in 20 normal subjects and 39 patients with various intraventricular conduction abnormalities, including 25 patients with Wolff-Parkinson-White (WPW) syndrome. Cardiac imaging was performed in the modified left anterior oblique, right anterior oblique, and left lateral projections. In WPW syndrome, early contraction sites which were not seen in normal subjects were detected at the ventricular base in phase images. These anomalous early contraction sites disappeared after successful suppression of conduction through an accessory pathway by intravenous procainamide. These sites are believed to correspond to the location of the bundle of Kent and were consistent with the electrocardiographic findings. Phase mapping is a suitable noninvasive method to locate the position of the bundle of Kent and evaluate the ventricular contraction pattern in WPW syndrome and other intraventricular conduction abnormalities. (author).

  15. Phase analysis of regional and global ventricular contraction patterns in Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Konishi, Tokuji; Koyama, Takao; Ichikawa, Takehiko

    1989-01-01

    Multigated blood pool scintigraphy was performed in 20 normal subjects and 39 patients with various intraventricular conduction abnormalities, including 25 patients with Wolff-Parkinson-White (WPW) syndrome. Cardiac imaging was performed in the modified left anterior oblique, right anterior oblique, and left lateral projections. In WPW syndrome, early contraction sites which were not seen in normal subjects were detected at the ventricular base in phase images. These anomalous early contraction sites disappeared after successful suppression of conduction through an accessory pathway by intravenous procainamide. These sites are believed to correspond to the location of the bundle of Kent and were consistent with the electrocardiographic findings. Phase mapping is a suitable noninvasive method to locate the position of the bundle of Kent and evaluate the ventricular contraction pattern in WPW syndrome and other intraventricular conduction abnormalities. (author)

  16. Prospective comparison of MR imaging (1.5 T) and CT detection of small intracranial metastases

    International Nuclear Information System (INIS)

    Dowd, C.F.; Dillon, W.P.; Laxer, K.; Norman, D.; Newton, T.H.

    1987-01-01

    Prior studies indicate lack of MR imaging sensitivity in the evaluation of intractable seizure patients. The authors reviewed MR imaging studies of 15 patients with intractable seizures. High-quality thin-section multiplanar images were obtained with electrocardiographic gating and/or flow compensation techniques and a 1.5-T General Electric Signa unit. Correlation with intracranial electro-encephalography (EEG), CT, and pathology was obtained in all patients. Abnormalities on MR imaging were detected in all but one patient. Pathology revealed MTS in 12 of 15 patients. Other entities included heterotopias and cavernous angiomas. The authors' study indicates that high-resolution, flow-compensated MR imaging is quite sensitive for localization of eleptogenic structural abnormalities and complements EEG

  17. Ultrasonography for Noninvasive Assessment of Portal Hypertension.

    Science.gov (United States)

    Maruyama, Hitoshi; Yokosuka, Osamu

    2017-07-15

    Portal hypertension is a major pathophysiology in patients with cirrhosis. Portal pressure is the gold standard to evaluate the severity of portal hypertension, and radiological intervention is the only procedure for pressure measurement. Ultrasound (US) is a simple and noninvasive imaging modality available worldwide. B-mode imaging allows broad applications for patients to detect and characterize chronic liver diseases and focal hepatic lesions. The Doppler technique offers real-time observation of blood flow with qualitative and quantitative assessments, and the application of microbubble-based contrast agents has improved the detectability of peripheral blood flow. In addition, elastography for the liver and spleen covers a wider field beyond the original purpose of fibrosis assessment. These developments enhance the practical use of US in the evaluation of portal hemodynamic abnormalities. This article reviews the recent progress of US in the assessment of portal hypertension.

  18. Exercise thallium testing in ventricular preexcitation

    Energy Technology Data Exchange (ETDEWEB)

    Archer, S.; Gornick, C.; Grund, F.; Shafer, R.; Weir, E.K.

    1987-05-01

    Ventricular preexcitation, as seen in Wolff-Parkinson-White syndrome, results in a high frequency of positive exercise electrocardiographic responses. Why this occurs is unknown but is not believed to reflect myocardial ischemia. Exercise thallium testing is often used for noninvasive assessment of coronary artery disease in patients with conditions known to result in false-positive electrocardiographic responses. To assess the effects of ventricular preexcitation on exercise thallium testing, 8 men (aged 42 +/- 4 years) with this finding were studied. No subject had signs or symptoms of coronary artery disease. Subjects exercised on a bicycle ergometer to a double product of 26,000 +/- 2,000 (+/- standard error of mean). All but one of the subjects had at least 1 mm of ST-segment depression. Tests were terminated because of fatigue or dyspnea and no patient had chest pain. Thallium test results were abnormal in 5 patients, 2 of whom had stress defects as well as abnormally delayed thallium washout. One of these subjects had normal coronary arteries on angiography with a negative ergonovine challenge, and both had normal exercise radionuclide ventriculographic studies. Delayed thallium washout was noted in 3 of the subjects with ventricular preexcitation and normal stress images. This study suggests that exercise thallium testing is frequently abnormal in subjects with ventricular preexcitation. Ventricular preexcitation may cause dyssynergy of ventricular activation, which could alter myocardial thallium handling, much as occurs with left bundle branch block. Exercise radionuclide ventriculography may be a better test for noninvasive assessment of coronary artery disease in patients with ventricular preexcitation.

  19. Exercise thallium testing in ventricular preexcitation

    International Nuclear Information System (INIS)

    Archer, S.; Gornick, C.; Grund, F.; Shafer, R.; Weir, E.K.

    1987-01-01

    Ventricular preexcitation, as seen in Wolff-Parkinson-White syndrome, results in a high frequency of positive exercise electrocardiographic responses. Why this occurs is unknown but is not believed to reflect myocardial ischemia. Exercise thallium testing is often used for noninvasive assessment of coronary artery disease in patients with conditions known to result in false-positive electrocardiographic responses. To assess the effects of ventricular preexcitation on exercise thallium testing, 8 men (aged 42 +/- 4 years) with this finding were studied. No subject had signs or symptoms of coronary artery disease. Subjects exercised on a bicycle ergometer to a double product of 26,000 +/- 2,000 (+/- standard error of mean). All but one of the subjects had at least 1 mm of ST-segment depression. Tests were terminated because of fatigue or dyspnea and no patient had chest pain. Thallium test results were abnormal in 5 patients, 2 of whom had stress defects as well as abnormally delayed thallium washout. One of these subjects had normal coronary arteries on angiography with a negative ergonovine challenge, and both had normal exercise radionuclide ventriculographic studies. Delayed thallium washout was noted in 3 of the subjects with ventricular preexcitation and normal stress images. This study suggests that exercise thallium testing is frequently abnormal in subjects with ventricular preexcitation. Ventricular preexcitation may cause dyssynergy of ventricular activation, which could alter myocardial thallium handling, much as occurs with left bundle branch block. Exercise radionuclide ventriculography may be a better test for noninvasive assessment of coronary artery disease in patients with ventricular preexcitation

  20. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Children's (pediatric) abdominal ultrasound imaging produces pictures ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  2. Noninvasive imaging of tumor integrin expression using 18F-labeled RGD dimer peptide with PEG4 linkers

    International Nuclear Information System (INIS)

    Liu, Zhaofei; Liu, Shuanglong; Wang, Fan; Liu, Shuang; Chen, Xiaoyuan

    2009-01-01

    Various radiolabeled Arg-Gly-Asp (RGD) peptides have been previously investigated for tumor integrin α v β 3 imaging. To further develop RGD radiotracers with enhanced tumor-targeting efficacy and improved in vivo pharmacokinetics, we designed a new RGD homodimeric peptide with two PEG 4 spacers (PEG 4 = 15-amino-4,7,10,13-tetraoxapentadecanoic acid) between the two monomeric RGD motifs and one PEG 4 linker on the glutamate α-amino group ( 18 F-labeled PEG 4 -E[PEG 4 -c(RGDfK)] 2 , P-PRGD2), as a promising agent for noninvasive imaging of integrin expression in mouse models. P-PRGD2 was labeled with 18 F via 4-nitrophenyl 2- 18 F-fluoropropionate ( 18 F-FP) prosthetic group. In vitro and in vivo characteristics of the new dimeric RGD peptide tracer 18 F-FP-P-PRGD2 were investigated and compared with those of 18 F-FP-P-RGD2 ( 18 F-labeled RGD dimer without two PEG 4 spacers between the two RGD motifs). The ability of 18 F-FP-P-PRGD2 to image tumor vascular integrin expression was evaluated in a 4T1 murine breast tumor model. With the insertion of two PEG 4 spacers between the two RGD motifs, 18 F-FP-P-PRGD2 showed enhanced integrin α v β 3 -binding affinity, increased tumor uptake and tumor-to-nontumor background ratios compared with 18 F-FP-P-RGD2 in U87MG tumors. MicroPET imaging with 18 F-FP-P-PRGD2 revealed high tumor contrast and low background in tumor-bearing nude mice. Biodistribution studies confirmed the in vivo integrin α v β 3 -binding specificity of 18 F-FP-P-RGD2. 18 F-FP-P-PRGD2 can specifically image integrin α v β 3 on the activated endothelial cells of tumor neovasculature. 18 F-FP-P-PRGD2 can provide important information on integrin expression on the tumor vasculature. The high integrin binding affinity and specificity, excellent pharmacokinetic properties and metabolic stability make the new RGD dimeric tracer 18 F-FP-P-PRGD2 a promising agent for PET imaging of tumor angiogenesis and for monitoring the efficacy of antiangiogenic

  3. Characterisation of a novel transmission Raman spectroscopy platform for non-invasive detection of breast micro-calcifications

    Science.gov (United States)

    Ghita, Adrian; Matousek, Pavel; Stone, Nick

    2018-02-01

    Our work focuses on the development of a medical Raman spectroscopy based platform to non-invasively detect and determine in-vivo molecular information deep inside biological tissues by monitoring the chemical composition of breast calcifications. The ultimate goal is to replace a needle biopsy which typically follows the detection of an abnormality in mammographic images. Here we report the non-invasive detection of calcium oxalate monohydrate in tissue through 40 mm of phantom tissues using our recently developed advanced Raman instrument complementing our previous detection of calcium hydroxyapatite through this thickness of tissue. The ability to detect these two key types of calcifications opens avenues for the development of non-invasive in-vivo breast cancer diagnostic tool in the future.

  4. Application of quantum dot nanoparticles for potential non-invasive bio-imaging of mammalian spermatozoa

    Science.gov (United States)

    Various obstacles are encountered by mammalian spermatozoa during their journey through the female genital tract, and only few or none will reach the site of fertilization. Currently, there are limited technical approaches for non-invasive investigation of spermatozoa migration after insemination. A...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  6. Non-invasive means of measuring hepatic fat content.

    Science.gov (United States)

    Mehta, Sanjeev-R; Thomas, E-Louise; Bell, Jimmy-D; Johnston, Desmond-G; Taylor-Robinson, Simon-D

    2008-06-14

    Hepatic steatosis affects 20% to 30% of the general adult population in the western world. Currently, the technique of choice for determining hepatic fat deposition and the stage of fibrosis is liver biopsy. However, it is an invasive procedure and its use is limited, particularly in children. It may also be subject to sampling error. Non-invasive techniques such as ultrasound, computerised tomography (CT), magnetic resonance imaging (MRI) and proton magnetic resonance spectroscopy ((1)H MRS) can detect hepatic steatosis, but currently cannot distinguish between simple steatosis and steatohepatitis, or stage the degree of fibrosis accurately. Ultrasound is widely used to detect hepatic steatosis, but its sensitivity is reduced in the morbidly obese and also in those with small amounts of fatty infiltration. It has been used to grade hepatic fat content, but this is subjective. CT can detect hepatic steatosis, but exposes subjects to ionising radiation, thus limiting its use in longitudinal studies and in children. Recently, magnetic resonance (MR) techniques using chemical shift imaging have provided a quantitative assessment of the degree of hepatic fatty infiltration, which correlates well with liver biopsy results in the same patients. Similarly, in vivo (1)H MRS is a fast, safe, non-invasive method for the quantification of intrahepatocellular lipid (IHCL) levels. Both techniques will be useful tools in future longitudinal clinical studies, either in examining the natural history of conditions causing hepatic steatosis (e.g. non-alcoholic fatty liver disease), or in testing new treatments for these conditions.

  7. Clinical evaluation of non-invasive perfusion-weighted MRI

    International Nuclear Information System (INIS)

    Takasu, Miyuki

    2000-01-01

    A spin labeling method to measure cerebral blood flow without a contrast medium was developed and applied clinically to obtain a non-invasive perfusion-weighted image. The purpose of this study is to compare the non-invasive perfusion-weighted image using FAIR with the well-established PWI using a bolus injection of Gd-DTPA. Of 41 lesions which revealed decreased perfusion, 13 were shown to be low signal intensity areas on FAIR. Therefore, detection rate of FAIR for hypoperfusion was 32%. Of 8 lesions which revealed increased perfusion, 7 demonstrated high intensity on FAIR. Therefore, detection rate of FAIR for hyperperfusion was 88%. Seven lesions were found to have a mean pixel value of zero on PWI. Of these lesions, 5 lesions could be detected as high signal intensity area on FAIR. The rCBV- and rCBF index ratios of hypoperfused lesions detected on FAIR were significantly lower than those of lesions which were not detected on FAIR (p=0.007, p=0.01). As concerns the lesions detected of FAIR, there were positive correlation between rCBV- or rCBF index ratio and FAIR signal ratio (rCBV ratio: ρ=0.873, p=0.0002, rCBF index ratio: ρ=0.858, p=0.0003). FAIR is valuable clinical tool to detect perfusion abnormality semi-quantitatively without contrast medium, although it showed relatively low detection rate for hypoperfused lesions. (author)

  8. Non-Invasive In Vivo Ultrasound Temperature Estimation

    Science.gov (United States)

    Bayat, Mahdi

    New emerging technologies in thermal therapy require precise monitoring and control of the delivered thermal dose in a variety of situations. The therapeutic temperature changes in target tissues range from few degrees for releasing chemotherapy drugs encapsulated in the thermosensitive liposomes to boiling temperatures in complete ablation of tumors via cell necrosis. High intensity focused ultrasound (HIFU) has emerged as a promising modality for noninvasive surgery due to its ability to create precise mechanical and thermal effects at the target without affecting surrounding tissues. An essential element in all these procedures, however, is accurate estimation of the target tissue temperature during the procedure to ensure its safety and efficacy. The advent of diagnostic imaging tools for guidance of thermal therapy was a key factor in the clinical acceptance of these minimally invasive or noninvasive methods. More recently, ultrasound and magnetic resonance (MR) thermography techniques have been proposed for guidance, monitoring, and control of noninvasive thermal therapies. MR thermography has shown acceptable sensitivity and accuracy in imaging temperature change and it is currently FDA-approved on clinical HIFU units. However, it suffers from limitations like cost of integration with ultrasound therapy system and slow rate of imaging for real time guidance. Ultrasound, on the other hand, has the advantage of real time imaging and ease of integration with the therapy system. An infinitesimal model for imaging temperature change using pulse-echo ultrasound has been demonstrated, including in vivo small-animal imaging. However, this model suffers from limitations that prevent demonstration in more clinically-relevant settings. One limitation stems from the infinitesimal nature of the model, which results in spatial inconsistencies of the estimated temperature field. Another limitation is the sensitivity to tissue motion and deformation during in vivo, which

  9. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  11. NONINVASIVE DETERMINATION OF KNEE CARTILAGE DEFORMATION DURING JUMPING

    Directory of Open Access Journals (Sweden)

    Djordje Kosanic

    2009-12-01

    Full Text Available The purpose of this investigation was to use a combination of image processing, force measurements and finite element modeling to calculate deformation of the knee cartilage during jumping. Professional athletes performed jumps analyzed using a force plate and high-speed video camera system. Image processing was performed on each frame of video using a color recognition algorithm. A simplified mass-spring-damper model was utilized for determination of global force and moment on the knee. Custom software for fitting the coupling characteristics was created. Simulated results were used as input data for the finite element calculation of cartilage deformation in the athlete's knee. Computer simulation data was compared with the average experimental ground reaction forces. The results show the three-dimensional mechanical deformation distribution inside the cartilage volume. A combination of the image recognition technology, force plate measurements and the finite element cartilage deformation in the knee may be used in the future as an effective noninvasive tool for prediction of injury during jumping

  12. Molecular and parametric imaging with iron oxides

    International Nuclear Information System (INIS)

    Matuszewski, L.; Bremer, C.; Tombach, B.; Heindel, W.

    2007-01-01

    Superparamagnetic iron oxide (SPIO) contrast agents, clinically established for high resolution magnetic resonance imaging of reticuloendothelial system containing anatomical structures, can additionally be exploited for the non-invasive characterization and quantification of pathology down to the molecular level. In this context, SPIOs can be applied for non-invasive cell tracking, quantification of tissue perfusion and target specific imaging, as well as for the detection of gene expression. This article provides an overview of new applications for clinically approved iron oxides as well of new, modified SPIO contrast agents for parametric and molecular imaging. (orig.) [de

  13. Non-invasive imaging methods applied to neo- and paleontological cephalopod research

    Science.gov (United States)

    Hoffmann, R.; Schultz, J. A.; Schellhorn, R.; Rybacki, E.; Keupp, H.; Gerden, S. R.; Lemanis, R.; Zachow, S.

    2013-11-01

    Several non-invasive methods are common practice in natural sciences today. Here we present how they can be applied and contribute to current topics in cephalopod (paleo-) biology. Different methods will be compared in terms of time necessary to acquire the data, amount of data, accuracy/resolution, minimum-maximum size of objects that can be studied, of the degree of post-processing needed and availability. Main application of the methods is seen in morphometry and volumetry of cephalopod shells in order to improve our understanding of diversity and disparity, functional morphology and biology of extinct and extant cephalopods.

  14. Relative value of clinical variables, bicycle ergometry, rest radionuclide ventriculography and 24 hour ambulatory electrocardiographic monitoring at discharge to predict 1 year survival after myocardial infarction

    NARCIS (Netherlands)

    P.M. Fioretti (Paolo); R.W. Brower (Ronald); M.L. Simoons (Maarten); H.J. ten Katen (Harald); A. Beelen (Anita); T. Baardman (Taco); J. Lubsen (Jacob); P.G. Hugenholtz (Paul)

    1986-01-01

    textabstractThe relative value of predischarge clinical variables, bicycle ergometry, radionuclide ventriculography and 24 hour ambulatory electrocardiographic monitoring for predicting survival during the first year in 351 hospital survivors of acute myocardial infarction was assessed. Discriminant

  15. Non-invasive grading of brain tumours using dynamic amino acid PET imaging: does it work for 11C-Methionine?

    International Nuclear Information System (INIS)

    Moulin-Romsee, Gerard; D'Hondt, Eduard; Mortelmans, Luc; Laere, Koen van; Groot, Tjibbe de; Goffin, Jan; Sciot, Raf; Menten, Johan; Bormans, Guy

    2007-01-01

    Static imaging of amino acids does not allow differentiation of low versus high grade brain tumours. It has been shown that dynamic imaging of the amino acid analogue 18 F-fluoroethyltyrosine (FET) can achieve this goal. In many centres, 11 C-methionine (MET) is used for tumour imaging, but no clinical studies on the use of dynamic scanning for grading have been performed. Thirty-four patients with primary brain glioma and histopathological confirmation were retrospectively studied using 40 min dynamic MET-PET with 220 MBq 11C-methionine. In relation to histopathological grading, various metabolic indices and temporal parameters as documented by Poepperl et al. (JNM 2006;47:393-403) were analyzed. None of the evaluated static or temporal parameters allowed discrimination between high and low grade tumours. On average, low grade tumours showed washout after the initial uptake maximum, while both increases and decreases were seen for high grade tumours. Only the relative early versus late uptake ratio showed a trend towards significance (-0.16 ± 0.17 for low grade versus 0.01 ± 0.25 for high grade; p = 0.07). Unlike FET-PET, the uptake characteristics of MET-PET do not allow classification of low and high grade tumours on an individual patient basis. Since literature data indicate that both tracers have a similar performance regarding biopsy location, tumour delineation, and detection of recurrence, FET-PET should be advocated over MET-PET as its uptake mechanism also allows noninvasive grading in glioma. (orig.)

  16. Electrocardiographic, echocardiographic, and indirect blood pressure evaluation in dogs subjected to different sedation protocols

    Directory of Open Access Journals (Sweden)

    Helena Mondardo Cardoso

    Full Text Available ABSTRACT: The present study aimed to evaluate the effects of different sedation protocols on blood pressure and echocardiographic and electrocardiographic parameters in dogs. In total, 24 male mixed-breed dogs with a mean weight of 9.87±3.0kg were used.Animals were randomly divided into four groups (n=6, which were subjected to sedation using the following protocols: acepromazine (0.05mgkg-1 and butorphanol (0.3mgkg-1 (AB; acepromazine (0.05mgkg-1and methadone (0.5mgkg-1 (AM; acepromazine (0.03mgkg-1, methadone (0.5mgkg-1, and midazolam (0.3mgkg-1(MAM; and methadone only (0.5mgkg-1 (M. Indirect blood pressure (BP measurements and computerized electrocardiography (ECG and echocardiography (ECO were performed immediately before the application of the sedation protocol (baseline, and the same evaluations were repeated after 15 minutes. BP decreased in groups AB, MAM, and AM compared to baseline values. Electrocardiographic measurements showed decreased heart rates (HRs after sedation in all groups, and bradycardia was observed after sedation in two dogs from group M and one animal from group AM. The P-wave duration increased after sedation in groups AM and M. After sedation, no changes in cardiac dimensions were revealed byECO.Fractional shortening (FS decreased after sedation in the AM group, and dogs from group AB exhibited a smaller decrease in FS compared with the other groups. The cardiac index (CI was lower in groups AM and M than in the other groups. Animals from group AB were less resistant to examination and exhibited the most favorable sedation scores. It was concluded that the combination of acepromazine and butorphanol was the best sedation protocol for performing echocardiogram measurementsbecause dogs were less resistant to examinations and echocardiographic parameters of FS and CI remained stable.

  17. Ethnic differences in electrocardiographic amplitude measurements

    International Nuclear Information System (INIS)

    Mansi, Ishak A.; Nash, Ira S.

    2004-01-01

    There is a controversy regarding ethnic differences in electrocardiographic (ECG) patterns because of the potentially confounding socioeconomic, nutritional, environmental and occupational factors. We reviewed the first 1000 medical files of a multiethnic community, where all individuals shared similar living conditions. Only healthy adults age 15 to 60 years were included. Wave amplitudes were measured manually from the standard 12lead ECG. Minnesota coding was used. ECG from 597 subjects were included in the study: 350 Saudi Arabians, 95 Indians, 17 Sri-Lankans, 39 Filipinos, and 57 Caucasians; 349 were men. the mean +-SD of Sokolow-Lyon voltage (SLV) in men was signifcantly different among ethnic groups (2.9+-0.86, 2.64+-0.79, 2.73+-0.72, 3.23+-0.61, 2.94+-0.6, 2.58+-0.79 mV, P=0.0006, for Saudi's, Indians, Jordanians, Filipinos, Sri-Lankans, and Caucasians, respectively). SLV was similar among ethnic groups in women. The prevalence of early transition pattern was also different among ethnic groups in men but not women (15.8%, 34.6%, 17.9%, 21.7%, 35.3%, 26.8% in Suadi, Indian, Jordanian, Filipino, Sri-Lankan, and Caucasian, respectively, P=0.037). T wave amplitude was significantly different among ethnic groups in selected lead. ECG wave amplitude differs with ethnic region even when other factors are similar. Using SLV of 3.5 mV as a criterion may overestimate the incidence of left ventricular hypertrophy in some ethnic groups. The pattern of high R wave in lead V1is common in healthy adults in certain ethnic groups. T wave height differs with ethnic origin and sex. (author)

  18. ELECTROCARDIOGRAPHIC CHANGES OBSERVED IN HAEMORRHAGIC AND ISCHAEMIC CEREBROVASCULAR DISEASES

    Directory of Open Access Journals (Sweden)

    Channappa

    2016-03-01

    Full Text Available INTRODUCTION Cardiac abnormalities are relatively common after acute neurologic injury. Disturbances can vary in severity from transient ECG abnormalities to profound myocardial injury and dysfunction. CNS is involved in the generation of cardiac arrhythmias and dysfunction even in an otherwise normal myocardium. AIM To find out proportion of ECG changes observed in ischaemic and haemorrhagic stroke. MATERIALS AND METHODS The Electrocardiographs of 100 patients with acute stroke were studied to find out the types of ECG abnormalities among different types of stroke. RESULTS In our study, the most common ECG abnormalities associated with stroke were prolonged QTc interval, ST-T segment abnormalities, prominent U wave and arrhythmias. Trop-I was positive in 12.8% patients with ECG changes. Statistical significance was found in association with Trop-I positivity and ST depression. CONCLUSION Usually patients with heart disease present with arrhythmias and Ischaemic like ECG changes. But these changes are also seen most often in the patients with presenting with stroke who didn’t have any past history of heart disease. This shows that arrhythmias and ischaemic ECG abnormalities are primarily evolved due to central nervous system disorders.

  19. Electrocardiographic findings in acute cerebrovascular hemorrhage a prospective study of 70 patients

    Directory of Open Access Journals (Sweden)

    Walter Oleschko Arruda

    1992-09-01

    Full Text Available Seventy patients with hemorrhagic stroke were prospectively evaluated regarding the electrocardiographic abnormalities observed within the first 48 hours of the ictus. Group I comprised 55 patients with spontaneous cerebral hemorrhage, and group II 15 patients with subarachnoid hemorrhage. Patients taking cardiac drugs (beta blockers, calcium-channel blockers, inotropic drugs or with severe metabolic/electrolyte disturbances were excluded. The most common ECG abnormality was a prolonged Q-Tc interval: group I, 37 (67.2%; group II, 8 (53.3%. Only 4 (7.2% patients of group I and no patient of group II had a normal ECG. No relation was found between the site of the intracerebral hematoma and the occurrence of any particular ECG change. A prolonged Q-Tc may be related to the development of severe cardiac arrhythmias observed in some patients with acute cerebral hemorrhage.

  20. Detection and assessment of unstable angina using myocardial perfusion imaging: Comparison between technetium-99m sestamibi SPECT and 12-lead electrocardiogram

    International Nuclear Information System (INIS)

    Gregoire, J.; Theroux, P.

    1990-01-01

    Forty-five studies using technetium-99m (Tc-99m) sestamibi single photon emission computed tomography (SPECT) were performed on patients hospitalized for spontaneous chest pain suggestive of myocardial ischemia. The studies were done after an injection during an episode of chest pain and a repeated injection when the patients were free of pain. All patients were hospitalized with a presumed diagnosis of unstable angina, and none had evidence of a previous myocardial infarction. The presence of a perfusion defect observed with Tc-99m sestamibi injected during chest pain had a 96% sensitivity and a 79% specificity for the detection of significant coronary artery disease (stenosis greater than or equal to 50%) on subsequent angiography. When the criterion of a larger perfusion defect during pain compared to absence of pain was used, the sensitivity was 81% and the specificity was 84%. In contrast, transient electrocardiographic ischemic changes during pain had a sensitivity of 35% and a specificity of 68%; electrocardiographic changes during or outside episodes of chest pain had a sensitivity of 65% and a specificity of 63% for the diagnosis. Tc-99m sestamibi SPECT represents a reliable noninvasive diagnostic tool that could aid in the diagnosis of myocardial ischemia in patients with spontaneous chest pain and provide additional information to that provided by the electrocardiogram

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  2. Non-invasive or minimally invasive autopsy compared to conventional autopsy of suspected natural deaths in adults: a systematic review.

    Science.gov (United States)

    Blokker, Britt M; Wagensveld, Ivo M; Weustink, Annick C; Oosterhuis, J Wolter; Hunink, M G Myriam

    2016-04-01

    Autopsies are used for healthcare quality control and improving medical knowledge. Because autopsy rates are declining worldwide, various non-invasive or minimally invasive autopsy methods are now being developed. To investigate whether these might replace the invasive autopsies conventionally performed in naturally deceased adults, we systematically reviewed original prospective validation studies. We searched six databases. Two reviewers independently selected articles and extracted data. Methods and patient groups were too heterogeneous for meaningful meta-analysis of outcomes. Sixteen of 1538 articles met our inclusion criteria. Eight studies used a blinded comparison; ten included less than 30 appropriate cases. Thirteen studies used radiological imaging (seven dealt solely with non-invasive procedures), two thoracoscopy and laparoscopy, and one sampling without imaging. Combining CT and MR was the best non-invasive method (agreement for cause of death: 70 %, 95%CI: 62.6; 76.4), but minimally invasive methods surpassed non-invasive methods. The highest sensitivity for cause of death (90.9 %, 95%CI: 74.5; 97.6, suspected duplicates excluded) was achieved in recent studies combining CT, CT-angiography and biopsies. Minimally invasive autopsies including biopsies performed best. To establish a feasible alternative to conventional autopsy and to increase consent to post-mortem investigations, further research in larger study groups is needed. • Health care quality control benefits from clinical feedback provided by (alternative) autopsies. • So far, sixteen studies investigated alternative autopsy methods for naturally deceased adults. • Thirteen studies used radiological imaging modalities, eight tissue biopsies, and three CT-angiography. • Combined CT, CT-angiography and biopsies were most sensitive diagnosing cause of death.

  3. Noninvasive monitoring of cancer therapy induced activated T cells using [18F]FB-IL-2 PET imaging.

    Science.gov (United States)

    Hartimath, S V; Draghiciu, O; van de Wall, S; Manuelli, V; Dierckx, R A J O; Nijman, H W; Daemen, T; de Vries, E F J

    2017-01-01

    Cancer immunotherapy urgently calls for methods to monitor immune responses at the site of the cancer. Since activated T lymphocytes may serve as a hallmark for anticancer responses, we targeted these cells using the radiotracer N-(4-[ 18 F]fluorobenzoyl)-interleukin-2 ([ 18 F]FB-IL-2) for positron emission tomography (PET) imaging. Thus, we noninvasively monitored the effects of local tumor irradiation and/or immunization on tumor-infiltrating and systemic activated lymphocytes in tumor-bearing mice. A 10- and 27-fold higher [ 18 F]FB-IL-2 uptake was observed in tumors of mice receiving tumor irradiation alone or in combination with immunization, respectively. This increased uptake was extended to several non-target tissues. Administration of the CXCR4 antagonist AMD3100 reduced tracer uptake by 2.8-fold, indicating a CXCR4-dependent infiltration of activated T lymphocytes upon cancer treatment. In conclusion, [ 18 F]FB-IL-2 PET can serve as a clinical biomarker to monitor treatment-induced infiltration of activated T lymphocytes and, on that basis, may guide cancer immunotherapies.

  4. Synthesis of magnetic resonance–, X-ray– and ultrasound-visible alginate microcapsules for immunoisolation and noninvasive imaging of cellular therapeutics

    Science.gov (United States)

    Barnett, Brad P; Arepally, Aravind; Stuber, Matthias; Arifin, Dian R; Kraitchman, Dara L; Bulte, Jeff W M

    2011-01-01

    Cell therapy has the potential to treat or cure a wide variety of diseases. Non-invasive cell tracking techniques are, however, necessary to translate this approach to the clinical setting. This protocol details methods to create microcapsules that are visible by X-ray, ultrasound (US ) or magnetic resonance (MR) for the encapsulation and immunoisolation of cellular therapeutics. Three steps are generally used to encapsulate cellular therapeutics in an alginate matrix: (i) droplets of cell-containing liquid alginate are extruded, using an electrostatic generator, through a needle tip into a solution containing a dissolved divalent cation salt to form a solid gel; (ii) the resulting gelled spheres are coated with polycations as a cross-linker; and (iii) these complexes are then incubated in a second solution of alginate to form a semipermeable membrane composed of an inner and an outer layer of alginate. The microcapsules can be rendered visible during the first step by adding contrast agents to the primary alginate layer. Such contrast agents include superparamagnetic iron oxide for detection by 1H MR imaging (MRI); the radiopaque agents barium or bismuth sulfate for detection by X-ray modalities; or perfluorocarbon emulsions for multimodal detection by 19F MRI, X-ray and US imaging. The entire synthesis can be completed within 2 h. PMID:21799484

  5. Burn-injured tissue detection for debridement surgery through the combination of non-invasive optical imaging techniques.

    Science.gov (United States)

    Heredia-Juesas, Juan; Thatcher, Jeffrey E; Lu, Yang; Squiers, John J; King, Darlene; Fan, Wensheng; DiMaio, J Michael; Martinez-Lorenzo, Jose A

    2018-04-01

    The process of burn debridement is a challenging technique requiring significant skills to identify the regions that need excision and their appropriate excision depths. In order to assist surgeons, a machine learning tool is being developed to provide a quantitative assessment of burn-injured tissue. This paper presents three non-invasive optical imaging techniques capable of distinguishing four kinds of tissue-healthy skin, viable wound bed, shallow burn, and deep burn-during serial burn debridement in a porcine model. All combinations of these three techniques have been studied through a k-fold cross-validation method. In terms of global performance, the combination of all three techniques significantly improves the classification accuracy with respect to just one technique, from 0.42 up to more than 0.76. Furthermore, a non-linear spatial filtering based on the mode of a small neighborhood has been applied as a post-processing technique, in order to improve the performance of the classification. Using this technique, the global accuracy reaches a value close to 0.78 and, for some particular tissues and combination of techniques, the accuracy improves by 13%.

  6. High-resolution non-invasive 3D imaging of paint microstructure by synchrotron-based X-ray laminography

    International Nuclear Information System (INIS)

    Reischig, Peter; Helfen, Lukas; Wallert, Arie; Baumbach, Tilo; Dik, Joris

    2013-01-01

    The characterisation of the microstructure and micromechanical behaviour of paint is key to a range of problems related to the conservation or technical art history of paintings. Synchrotron-based X-ray laminography is demonstrated in this paper to image the local sub-surface microstructure in paintings in a non-invasive and non-destructive way. Based on absorption and phase contrast, the method can provide high-resolution 3D maps of the paint stratigraphy, including the substrate, and visualise small features, such as pigment particles, voids, cracks, wood cells, canvas fibres etc. Reconstructions may be indicative of local density or chemical composition due to increased attenuation of X-rays by elements of higher atomic number. The paint layers and their interfaces can be distinguished via variations in morphology or composition. Results of feasibility tests on a painting mockup (oak panel, chalk ground, vermilion and lead white paint) are shown, where lateral and depth resolution of up to a few micrometres is demonstrated. The method is well adapted to study the temporal evolution of the stratigraphy in test specimens and offers an alternative to destructive sampling of original works of art. (orig.)

  7. Coronary imaging techniques with emphasis on CT and MRI

    International Nuclear Information System (INIS)

    Lederlin, Mathieu; Latrabe, Valerie; Corneloup, Olivier; Cochet, Hubert; Montaudon, Michel; Laurent, Francois; Thambo, Jean-Benoit

    2011-01-01

    Coronary artery imaging in children is challenging, with high demands both on temporal and spatial resolution due to high heart rates and smaller anatomy. Although invasive conventional coronary angiography remains the benchmark technique, over the past 10 years, CT and MRI have emerged in the field of coronary imaging. The choice of hardware is important. For CT, the minimum requirement is a 64-channel scanner. The temporal resolution of the scanner is most important for optimising image quality and minimising radiation dose. Manufacturers have developed several modes of electrocardiographic (ECG) triggering to facilitate dose reduction. Recent technical advances have opened new possibilities in MRI coronary imaging. As a non-ionising radiation technique, MRI is of great interest in paediatric imaging. It is currently recommended in centres with appropriate expertise for the screening of patients with suspected congenital coronary anomalies. However, MRI is still not feasible in infants. This review describes and discusses the technical requirements and the pros and cons of all three techniques. (orig.)

  8. Evaluation of congenital heart disease by three-dimensional MR imaging

    International Nuclear Information System (INIS)

    Vannier, M.W.; Gutierrez, F.R.; Canter, C.E.; Yoffie, R.L.; Hildebolt, C.F.

    1988-01-01

    In an evaluation of the detectability of intra-and extracardiac morphologic defects with electrocardiographically gated magnetic resonance (MR) imaging, 100 patients were studied, including ten without and 90 with abnormalities. The abnormalities included septal defects, tetrology of Fallot, pulmonary atresia, transposition of the great vessels, and others. The patients with abnormalities were studied angiographically and with echocardiographic analyses. Two radiologists with cardiac MR imaging experience evaluated the scans in a blinded fashion, and the results were analyzed by means of receiver operating characteristic analysis. The diagnostic value of routine two-dimensional cardiac MR imaging was compared with that of three-dimensional reconstruction imaging and with the results of cardiac catheterization and echocardiography. The reported sensitivity and specificity of echocardiography in the detection of congenital heart disease is comparable to that of MR imaging. The differences in diagnostic value between various modalities for the imaging of congenital heart disease may be determined from the results of the preliminary series

  9. Non-invasive vascular imaging in perforator flap surgery

    International Nuclear Information System (INIS)

    Saba, Luca; Piga, Mario; Atzeni, Matteo; Ribuffo, Diego; Rozen, Warren Matthew; Alonso-Burgos, Alberto; Bura, Raffaella

    2013-01-01

    Preoperative imaging using a range of imaging modalities has become increasingly popular for preoperative planning in plastic surgery, in particular in perforator flap surgery. Modalities in this role include ultrasound (US), magnetic resonance angiography (MRA), and computed tomographic angiography (CTA). The evidence for the use of these techniques has been reported in only a handful of studies. In this paper we conducted a non-systematic review of the literature to establish the role for each of these modalities. The role of state-of-the-art vascular imaging as an application in perforator flap surgery is thus offered

  10. Technetium-99m-pyrophosphate myocardial imaging in unstable angina

    International Nuclear Information System (INIS)

    Willerson, J.T.; Parkey, R.W.; Lewis, S.E.; Buja, L.M.; Bonte, F.J.

    1980-01-01

    The authors have found that approximately one third of patients with the syndrome of unstable angina pectoris have abnormal 99mTc-pyrophosphate myocardial scintigrams even in the absence of abnormal enzymes and electrocardiographic confirmation of the presence of acute myocardial necrosis. Thus, 99mTc-pyrophosphate myocardial imaging technique appears to represent a sensitive means to detect acute multicellular injury associated with the clinical syndrome of unstable angina pectoris even when cardiac enzymes are normal and the electrocardiogram does not definitively document the presence of acute myocardial necrosis. (Auth.)

  11. Nuclear medicine imaging instrumentations for molecular imaging

    International Nuclear Information System (INIS)

    Chung, Yong Hyun; Song, Tae Yong; Choi, Yong

    2004-01-01

    Small animal models are extensively utilized in the study of biomedical sciences. Current animal experiments and analysis are largely restricted to in vitro measurements and need to sacrifice animals to perform tissue or molecular analysis. This prevents researchers from observing in vivo the natural evolution of the process under study. Imaging techniques can provide repeatedly in vivo anatomic and molecular information noninvasively. Small animal imaging systems have been developed to assess biological process in experimental animals and increasingly employed in the field of molecular imaging studies. This review outlines the current developments in nuclear medicine imaging instrumentations including fused multi-modality imaging systems for small animal imaging

  12. Acoustic radiation force impulse-imaging and transient elastography for non-invasive assessment of liver fibrosis and steatosis in NAFLD

    International Nuclear Information System (INIS)

    Friedrich-Rust, Mireen; Romen, Daniela; Vermehren, Johannes; Kriener, Susanne; Sadet, Dilek; Herrmann, Eva; Zeuzem, Stefan; Bojunga, Joerg

    2012-01-01

    Background: Transient elastography (TE) and acoustic radiation force impulse (ARFI)-imaging have shown promising results for the staging of liver fibrosis. Aim: The aim of the present study was to compare ARFI of the left and right liver lobe with TE using the standard and obese probes for the diagnosis of liver fibrosis in NAFL/NASH. In addition, liver steatosis is evaluated using the novel controlled attenuation parameter (CAP). Methods: Sixty-one patients with NAFLD/NASH were included in the study. All patients received TE with both probes, ARFI of both liver lobes and CAP. The results were compared with liver histology. Results: 57 patients were included in the final analysis. The diagnostic accuracy for TE measurements with the M-and XL-probe and for ARFI of the right and left liver lobe was 0.73, 0.84, 0.71 and 0.60 for the diagnosis of severe fibrosis, and 0.93, 0.93, 0.74 and 0.90 for the diagnosis of cirrhosis, respectively. No significant difference of results was observed between TE and ARFI in the subgroup of patients with reliable TE-measurement when taking into account the best results of both methods. However, while a significant correlation could be found for TE with histological liver fibrosis, the correlation of ARFI with liver fibrosis was not statistically significant. A significant correlation was found for CAP with histological steatosis (r = 0.49, p < 0.001). Conclusions: No significant difference in diagnostic accuracy for the non-invasive assessment of liver fibrosis was found for transient elastography and ARFI. Nevertheless TE significantly correlated with liver fibrosis while ARFI did not. CAP enables the non-invasive assessment of steatosis.

  13. In vivo non-invasive monitoring of collagen remodelling by two-photon microscopy after micro-ablative fractional laser resurfacing.

    Science.gov (United States)

    Cicchi, Riccardo; Kapsokalyvas, Dimitrios; Troiano, Michela; Campolmi, Piero; Morini, Cristiano; Massi, Daniela; Cannarozzo, Giovanni; Lotti, Torello; Pavone, Francesco Saverio

    2014-11-01

    Non-linear optical microscopy is becoming popular as a non-invasive in vivo imaging modality in dermatology. In this study, combined TPF and SHG microscopy were used to monitor collagen remodelling in vivo after micro-ablative fractional laser resurfacing. Papillary dermis of living subjects, covering a wide age range, was imaged immediately before and forty days after treatment. A qualitative visual examination of acquired images demonstrated an age-dependent remodelling effect on collagen. Additional quantitative analysis of new collagen production was performed by means of two image analysis methods. A higher increase in SHG to TPF ratio, corresponding to a stronger treatment effectiveness, was found in older subjects, whereas the effect was found to be negligible in young, and minimal in middle age subjects. Analysis of collagen images also showed a dependence of the treatment effectiveness with age but with controversial results. While the diagnostic potential of in vivo multiphoton microscopy has already been demonstrated for skin cancer and other skin diseases, here we first successfully explore its potential use for a non-invasive follow-up of a laser-based treatment. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  15. Contemporary imaging of mild TBI: the journey toward diffusion tensor imaging to assess neuronal damage.

    Science.gov (United States)

    Fox, W Christopher; Park, Min S; Belverud, Shawn; Klugh, Arnett; Rivet, Dennis; Tomlin, Jeffrey M

    2013-04-01

    To follow the progression of neuroimaging as a means of non-invasive evaluation of mild traumatic brain injury (mTBI) in order to provide recommendations based on reproducible, defined imaging findings. A comprehensive literature review and analysis of contemporary published articles was performed to study the progression of neuroimaging findings as a non-invasive 'biomarker' for mTBI. Multiple imaging modalities exist to support the evaluation of patients with mTBI, including ultrasound (US), computed tomography (CT), single photon emission computed tomography (SPECT), positron emission tomography (PET), and magnetic resonance imaging (MRI). These techniques continue to evolve with the development of fractional anisotropy (FA), fiber tractography (FT), and diffusion tensor imaging (DTI). Modern imaging techniques, when applied in the appropriate clinical setting, may serve as a valuable tool for diagnosis and management of patients with mTBI. An understanding of modern neuroanatomical imaging will enhance our ability to analyse injury and recognize the manifestations of mTBI.

  16. A non-invasive method of quantifying pancreatic volume in mice using micro-MRI.

    Directory of Open Access Journals (Sweden)

    Jose L Paredes

    Full Text Available In experimental models of pancreatic growth and recovery, changes in pancreatic size are assessed by euthanizing a large cohort of animals at varying time points and measuring organ mass. However, to ascertain this information in clinical practice, patients with pancreatic disorders routinely undergo non-invasive cross-sectional imaging of the pancreas using magnetic resonance imaging (MRI or computed tomography (CT. The aim of the current study was to develop a thin-sliced, optimized sequence protocol using a high field MRI to accurately calculate pancreatic volumes in the most common experimental animal, the mouse. Using a 7 Telsa Bruker micro-MRI system, we performed abdominal imaging in whole-fixed mice in three standard planes: axial, sagittal, and coronal. The contour of the pancreas was traced using Vitrea software and then transformed into a 3-dimensional (3D reconstruction, from which volumetric measurements were calculated. Images were optimized using heart perfusion-fixation, T1 sequence analysis, and 0.2 to 0.4 mm thick slices. As proof of principle, increases in pancreatic volume among mice of different ages correlated tightly with increasing body weight. In summary, this is the first study to measure pancreatic volumes in mice, using a high field 7 Tesla micro-MRI and a thin-sliced, optimized sequence protocol. We anticipate that micro-MRI will improve the ability to non-invasively quantify changes in pancreatic size and will dramatically reduce the number of animals required to serially assess pancreatic growth and recovery.

  17. Molecular imaging in stem cell-based therapies of cardiac diseases.

    Science.gov (United States)

    Li, Xiang; Hacker, Marcus

    2017-10-01

    In the past 15years, despite that regenerative medicine has shown great potential for cardiovascular diseases, the outcome and safety of stem cell transplantation has shown controversial results in the published literature. Medical imaging might be useful for monitoring and quantifying transplanted cells within the heart and to serially characterize the effects of stem cell therapy of the myocardium. From the multiple available noninvasive imaging techniques, magnetic resonance imaging and nuclear imaging by positron (PET) or single photon emission computer tomography (SPECT) are the most used clinical approaches to follow the fate of transplanted stem cells in vivo. In this article, we provide a review on the role of different noninvasive imaging modalities and discuss their advantages and disadvantages. We focus on the different in-vivo labeling and reporter gene imaging strategies for stem cell tracking as well as the concept and reliability to use imaging parameters as noninvasive surrogate endpoints for the evaluation of the post-therapeutic outcome. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... to a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive imaging ... over time. top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging ...

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Children's (pediatric) ... uterus Abdominal ultrasound images can be used to help diagnose appendicitis in children. Except for traumatic injury, ...

  20. Awake Craniotomy with Noninvasive Brain Mapping by 3-Tesla Functional Magnetic Resonance Imaging for Excision of Low-grade Glioma: A Case of a Young Patient from Pakistan.

    Science.gov (United States)

    Aleem Bhatti, Atta Ul; Jakhrani, Nasir Khan; Parekh, Maria Adnan

    2018-01-01

    The past few years have seen increasing support for gross total resection in the management of low-grade gliomas (LGGs), with a greater extent of resection correlated with better overall survival, progression-free survival, and time to malignant transformation. There is consistent evidence in literature supporting extent of safe resection as a good prognostic indicator as well as positively affecting seizure control, symptomatic relief in pressure symptoms, and longer progression-free and total survival. The operative goal in most LGG cases is to maximize the extent of resection for these benefits while avoiding postoperative neurologic deficits. Several advanced invasive and noninvasive surgical techniques such as intraoperative magnetic resonance imaging (MRI), fluorescence-guided surgery, intraoperative functional pathway mapping, and neuronavigation have been developed in an attempt to better achieve maximal safe resection. We present a case of LGG in a young patient with a 5-year history of refractory seizures and gradual onset walking difficulty. Serial MRI brain scans revealed a progressive increase in right frontal tumor size with substantial edema and parafalcine herniation. Noninvasive brain mapping by functional MRI (fMRI) and sleep-awake-sleep type of anesthesia with endotracheal tube insertion was utilized during an awake craniotomy. Histopathology confirmed a Grade II oligodendroglioma, and genetic analysis revealed no codeletion at 1p/19q. Neurological improvement was remarkable in terms of immediate motor improvement, and the patient remained completely seizure free on a single antiepileptic drug. There is no radiologic or clinical evidence of recurrence 6 months postoperatively. This is the first published report of an awake craniotomy for LGG in Pakistan. The contemporary concept of supratotal resection in LGGs advocates generous functional resection even beyond MRI findings rather than mere excision of oncological boundaries. This relatively

  1. On image quality enhancement in photoacoustic image reconstruction by motion compensation

    NARCIS (Netherlands)

    Willemink, Rene; Slump, Cornelis H.; van der Heijden, Ferdinand

    2006-01-01

    Photoacoustic (PA) imaging is a relatively new noninvasive medical imaging modality. It is a tech- nique which is harmless for the human body and uses pulsed optical energy. The process is based on the ab- sorption of the pulse of optical energy by an object leading to local temperature increases.

  2. Clinical characteristics in patients showing ischemic electrocardiographic changes during adenosine triphosphate loading single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Ohtaki, Yuka; Chikamori, Taishiro; Hida, Satoshi; Tanaka, Hirokazu; Igarashi, Yuko; Hatano, Tsuguhisa; Usui, Yasuhiro; Miyagi, Manabu; Yamashina, Akira

    2010-01-01

    Although ischemic electrocardiographic (ECG) changes during dipyridamole or adenosine infusion have been reported as a marker for severe coronary artery disease (CAD), few studies have focused on ST-segment changes with adenosine triphosphate (ATP)-loading myocardial single-photon emission computed tomography (SPECT). Between January 2003 and August 2008, 4650 consecutive patients underwent ATP-loading SPECT. After 1412 patients with left bundle branch block, pacemaker rhythm, or previous coronary revascularization were excluded, 16 out of 3238 patients (0.5%) showed ischemic ST-segment depression during ATP-loading myocardial SPECT. They were aged 67±11 years; 10 were men and 6 women. Of these patients, 8 demonstrated perfusion abnormalities, whereas the remaining 8 showed normal myocardial perfusion imaging. In 6 of the 8 patients with abnormal SPECT, coronary angiography was performed, revealing left main trunk disease in 1 patient, 3-vessel disease in 4, 1-vessel disease with proximal left ascending artery occlusion in 1, and an insignificant lesion in 1. By contrast, no major cardiac event was observed in the 8 patients with normal SPECT during follow-up for an average of 2 years. The prevalence of ischemic ST-segment changes during ATP loading is very rare. However, this finding should be taken into account since almost half of the patients, particularly those with perfusion abnormalities, may have severe CAD which requires coronary revascularization. (author)

  3. ST-segment deviation during 24-hour ambulatory electrocardiographic monitoring and exercise stress test in healthy male subjects 51 to 75 years of age: the Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Vaage-Nilsen, M; Rasmussen, Verner; Sørum, C

    1999-01-01

    or descending ST-segment depression of >/=0.15 mV during Holter monitoring or at the exercise test, respectively. Furthermore, the specificity was 0.95 when a horizontal or downsloping ST-segment depression of 0.1 mV was displayed in both the Holter and exercise electrocardiographic recording system......BACKGROUND: Although ST-segment deviation has been evaluated and used during many years both on continuous electrocardiographic Holter monitoring and during exercise stress testing, considerable controversy still remains concerning the prevalence and diagnostic significance of fortuitously...... discovered ST-segment deviation in asymptomatic healthy persons. METHODS AND RESULTS: The occurrence of ST-segment deviation was studied in a population of 63 clinically healthy male subjects 51 to 75 years of age, with the use of 24-hour Holter monitoring and exercise stress testing. The subjects were...

  4. Non-invasive dendrochronology of late-medieval objects in Oslo: refinement of a technique and discoveries

    Science.gov (United States)

    Daly, Aoife; Streeton, Noëlle L. W.

    2017-06-01

    A technique for non-invasive dendrochronological analysis of oak was developed for archaeological material, using an industrial CT scanner. Since 2013, this experience has been extended within the scope of the research project `After the Black Death: Painting and Polychrome Sculpture in Norway'. The source material for the project is a collection of late-medieval winged altarpieces, shrines, polychrome sculpture, and fragments from Norwegian churches, which are owned by the Museum of Cultural History, University of Oslo. The majority cannot be sampled, and many are too large to fit into the CT scanner. For these reasons, a combined approach was adopted, utilizing CT scanning where possible, but preceded by an `exposed-wood' imaging technique. Both non-invasive techniques have yielded reliable results, and CT scanning has confirmed the reliability of the imaging technique alone. This paper presents the analytical methods, along with results from two of the 13 objects under investigation. Results for reliable dates and provenances provide new foundations for historical interpretations.

  5. Small animal imaging. Basics and practical guide

    Energy Technology Data Exchange (ETDEWEB)

    Kiessling, Fabian [Aachen Univ. (RWTH) (Germany). Chair of Experimental Molecular Imaging; Pichler, Bernd J. (eds.) [Tuebingen Univ. (Germany). Lab. for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation

    2011-07-01

    Small animal imaging has been recognized as an important tool in preclinical research. Nevertheless, the results of non-invasive imaging are often disappointing owing to choice of a suboptimal imaging modality and/or shortcomings in study design, experimental setup, and data evaluation. This textbook is a practical guide to the use of non-invasive imaging in preclinical research. Each of the available imaging modalities is discussed in detail, with the assistance of numerous informative illustrations. In addition, many useful hints are provided on the installation of a small animal unit, study planning, animal handling, and the cost-effective performance of small animal imaging. Cross-calibration methods, data postprocessing, and special imaging applications are also considered in depth. This is the first book to cover all the practical basics in small animal imaging, and it will prove an invaluable aid for researchers, students, and technicians. (orig.)

  6. Small animal imaging. Basics and practical guide

    International Nuclear Information System (INIS)

    Kiessling, Fabian; Pichler, Bernd J.

    2011-01-01

    Small animal imaging has been recognized as an important tool in preclinical research. Nevertheless, the results of non-invasive imaging are often disappointing owing to choice of a suboptimal imaging modality and/or shortcomings in study design, experimental setup, and data evaluation. This textbook is a practical guide to the use of non-invasive imaging in preclinical research. Each of the available imaging modalities is discussed in detail, with the assistance of numerous informative illustrations. In addition, many useful hints are provided on the installation of a small animal unit, study planning, animal handling, and the cost-effective performance of small animal imaging. Cross-calibration methods, data postprocessing, and special imaging applications are also considered in depth. This is the first book to cover all the practical basics in small animal imaging, and it will prove an invaluable aid for researchers, students, and technicians. (orig.)

  7. Noninvasive ventilation in hypoxemic respiratory failure

    Directory of Open Access Journals (Sweden)

    Raja Dhar

    2016-01-01

    Full Text Available Noninvasive ventilation (NIV refers to positive pressure ventilation delivered through a noninvasive interface (nasal mask, facemask, or nasal plugs etc. Over the past decade its use has become more common as its benefits are increasingly recognized. This review will focus on the evidence supporting the use of NIV in various conditions resulting in acute hypoxemic respiratory failure (AHRF, that is, non-hypercapnic patients having acute respiratory failure in the absence of a cardiac origin or underlying chronic pulmonary disease. Outcomes depend on the patient's diagnosis and clinical characteristics. Patients should be monitored closely for signs of noninvasive ventilation failure and promptly intubated before a crisis develops. The application of noninvasive ventilation by a trained and experienced team, with careful patient selection, should optimize patient outcomes.

  8. Magnetic resonance imaging of the cardiovascular system: present state of the art and future potential

    International Nuclear Information System (INIS)

    Jacobson, H.G.

    1988-01-01

    State-of-the-art magnetic resonance imaging (MRI) generates high-resolution images of the cardiovascular system. Conventional MRI techniques provide images in six to ten minutes per tomographic slice. New strategies have substantially improved the speed of imaging. The technology is relatively expensive, and its cost-effectiveness remains to be defined in relation to other effective, less expensive, and noninvasive technologies, such as echocardiography and nuclear medicine. The ultimate role of MRI will depend on several factors, including the development of specific applications such as (1) noninvasive angiography, especially of the coronary arteries;(2) noninvasive, high-resolution assessment of regional myocardial blood flow distribution (e.g., using paramagnetic contrast agents); (3) characterization of myocardial diseases using proton-relaxation property changes; and (4) evaluation of in vivo myocardial biochemistry. The three-dimensional imaging capability and the ability to image cardiovascular structures without contrast material give MRI a potential advantage over existing noninvasive diagnostic imaging techniques. This report analyzes current applications of MRI to the cardiovascular system and speculates on their future

  9. Magnetic Resonance Imaging of Stroke

    NARCIS (Netherlands)

    Bouts, Mark. J. R. J.; Wu, O.; Dijkhuizen, R. M.

    2017-01-01

    Magnetic resonance imaging (MRI) provides a powerful (neuro)imaging modality for the diagnosis and outcome prediction after (acute) stroke. Since MRI allows noninvasive, longitudinal, and three-dimensional assessment of vessel occlusion (with magnetic resonance angiography (MRA)), tissue injury

  10. Non-invasive glucagon-like peptide-1 receptor imaging in pancreas with (18)F-Al labeled Cys(39)-exendin-4.

    Science.gov (United States)

    Mi, Baoming; Xu, Yuping; Pan, Donghui; Wang, Lizhen; Yang, Runlin; Yu, Chunjing; Wan, Weixing; Wu, Yiwei; Yang, Min

    2016-02-26

    Glucagon-like peptide-1 receptor (GLP-1R) is abundantly expressed on beta cells and may be an ideal target for the pancreas imaging. Monitoring the GLP-1R of pancreas could be benefit for understanding the pathophysiology of diabetes. In the present study, (18)F-Al labeled exendin-4 analog, (18)F-Al-NOTA-MAL-Cys(39)-exendin-4, was evaluated for PET imaging GLP-1R in the pancreas. The targeting of (18)F-Al labeled exendin-4 analog was examined in healthy and streptozotocin induced diabetic rats. Rats were injected with (18)F-Al-NOTA-MAL-Cys(39)-exendin-4 and microPET imaging was performed at 1 h postinjection, followed by ex vivo biodistribution. GLP-1R expression in pancreas was determined through post mortern examinations. The pancreas of healthy rats was readily visualized after administration of (18)F-Al-NOTA-MAL-Cys(39)-exendin-4, whereas the pancreas of diabetic rats, as well as those from rats co-injected with excess of unlabeled peptides, was barely visible by microPET. At 60 min postinjection, the pancreatic uptakes were 1.02 ± 0.15%ID/g and 0.23 ± 0.05%ID/g in healthy and diabetic rats respectively. Under block, the pancreatic uptakes of non-diabetic rats reduced to 0.21 ± 0.07%ID/g at the same time point. Biodistribution data and IHC staining confirmed the findings of the microPET imaging. The favorable preclinical data indicated that (18)F-Al-NOTA-MAL-Cys(39)-exendin-4may be suitable for non-invasive monitoring functional pancreatic beta cells. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Evaluation of biolistic gene transfer methods in vivo using non-invasive bioluminescent imaging techniques

    Directory of Open Access Journals (Sweden)

    Daniell Henry

    2011-06-01

    Full Text Available Abstract Background Gene therapy continues to hold great potential for treating many different types of disease and dysfunction. Safe and efficient techniques for gene transfer and expression in vivo are needed to enable gene therapeutic strategies to be effective in patients. Currently, the most commonly used methods employ replication-defective viral vectors for gene transfer, while physical gene transfer methods such as biolistic-mediated ("gene-gun" delivery to target tissues have not been as extensively explored. In the present study, we evaluated the efficacy of biolistic gene transfer techniques in vivo using non-invasive bioluminescent imaging (BLI methods. Results Plasmid DNA carrying the firefly luciferase (LUC reporter gene under the control of the human Cytomegalovirus (CMV promoter/enhancer was transfected into mouse skin and liver using biolistic methods. The plasmids were coupled to gold microspheres (1 μm diameter using different DNA Loading Ratios (DLRs, and "shot" into target tissues using a helium-driven gene gun. The optimal DLR was found to be in the range of 4-10. Bioluminescence was measured using an In Vivo Imaging System (IVIS-50 at various time-points following transfer. Biolistic gene transfer to mouse skin produced peak reporter gene expression one day after transfer. Expression remained detectable through four days, but declined to undetectable levels by six days following gene transfer. Maximum depth of tissue penetration following biolistic transfer to abdominal skin was 200-300 μm. Similarly, biolistic gene transfer to mouse liver in vivo also produced peak early expression followed by a decline over time. In contrast to skin, however, liver expression of the reporter gene was relatively stable 4-8 days post-biolistic gene transfer, and remained detectable for nearly two weeks. Conclusions The use of bioluminescence imaging techniques enabled efficient evaluation of reporter gene expression in vivo. Our results

  12. Molecular imaging by cardiovascular MR.

    Science.gov (United States)

    Cyrus, Tillmann; Lanza, Gregory M; Wickline, Samuel A

    2007-01-01

    Do molecularly-targeted contrast agents have what it takes to usher in a paradigm shift as to how we will image cardiovascular disease in the near future? Moreover, are non-invasive vulnerable plaque detection and preemptive treatments with these novel nanoparticulate agents within reach for clinical applications? In this article, we attempt to make a compelling case for how the advent of molecularly-targeted nanoparticle technology may change the way we detect atherosclerotic lesions, determine their clinical significance and even provide non-invasive treatments. Focusing on imaging with cardiovascular MR, an overview of the latest developments in this rapidly evolving field of so-called "intelligent" contrast agents that are able to interrogate the vascular wall and various complementary advanced imaging technologies are presented.

  13. Comparison of optical and power Doppler ultrasound imaging for non-invasive evaluation of arsenic trioxide as a vascular disrupting agent in tumors.

    Science.gov (United States)

    Alhasan, Mustafa K; Liu, Li; Lewis, Matthew A; Magnusson, Jennifer; Mason, Ralph P

    2012-01-01

    Small animal imaging provides diverse methods for evaluating tumor growth and acute response to therapy. This study compared the utility of non-invasive optical and ultrasound imaging to monitor growth of three diverse human tumor xenografts (brain U87-luc-mCherry, mammary MCF7-luc-mCherry, and prostate PC3-luc) growing in nude mice. Bioluminescence imaging (BLI), fluorescence imaging (FLI), and Power Doppler ultrasound (PD US) were then applied to examine acute vascular disruption following administration of arsenic trioxide (ATO).During initial tumor growth, strong correlations were found between manual caliper measured tumor volume and FLI intensity, BLI intensity following luciferin injection, and traditional B-mode US. Administration of ATO to established U87 tumors caused significant vascular shutdown within 2 hrs at all doses in the range 5 to 10 mg/kg in a dose dependant manner, as revealed by depressed bioluminescent light emission. At lower doses substantial recovery was seen within 4 hrs. At 8 mg/kg there was >85% reduction in tumor vascular perfusion, which remained depressed after 6 hrs, but showed some recovery after 24 hrs. Similar response was observed in MCF7 and PC3 tumors. Dynamic BLI and PD US each showed similar duration and percent reductions in tumor blood flow, but FLI showed no significant changes during the first 24 hrs.The results provide further evidence for comparable utility of optical and ultrasound imaging for monitoring tumor growth, More specifically, they confirm the utility of BLI and ultrasound imaging as facile assays of the vascular disruption in solid tumors based on ATO as a model agent.

  14. Noninvasive Localization of Accessory Pathways in Patients with Wolff-Parkinson-White Syndrome: A Strain Imaging Study

    Science.gov (United States)

    Esmaeilzadeh, Maryam; Omran, Mohammad Taghi Salehi; Maleki, Majid; Haghjoo, Majid; Noohi, Feridoun; Haghighi, Zahra Ojaghi; Sadeghpour, Anita; Davari, Paridokht Nakhostin; Abkenar, Hooman Bakhshandeh

    2013-01-01

    Background: Noninvasive techniques for the localization of the accessory pathways (APs) might help guide mapping procedures and ablation techniques. We sought to examine the diagnostic accuracy of strain imaging for the localization of the APs in Wolff-Parkinson-White syndrome. Methods: We prospectively studied 25 patients (mean age = 32 ± 17 years, 58.3% men) with evidence of pre-excitation on electrocardiography (ECG). Electromechanical interval was defined as the time difference between the onset of delta wave and the onset of regional myocardial contraction. Time differences between the onset of delta wave (δ) and the onset of regional myocardial contraction (δ-So), peak systolic motion (δ-Sm), regional strain (δ-ε), peak strain (δ-εp), and peak strain rate (δ-SRp) were measured. Results: There was a significant difference between time to onset of delta wave to onset of peak systolic motion (mean ± SD) in the AP location (A) and normal segments (B) versus that in the normal volunteers (C) [A: (57.08 ± 23.88 msec) vs. B: (75.20 ± 14.75) vs. C: (72.9 0 ± 11.16); p value (A vs. B) = 0.004 and p value (A vs. C) = 0.18] and [A: (49.17 ± 35.79) vs. B: (67.60 ± 14.51) vs. C: (67.40 ± 6.06 msec); p value (A vs. B) < 0.001 and p value (A vs. C) = 0.12, respectively]. Conclusion: Our study showed that strain imaging parameters [(δ-So) and (δ-Strain)] are superior to the ECG in the localization of the APs (84% vs. 76%). PMID:23967027

  15. Assessment of ischemic heart disease by dipyridamole stress electrocardiographic gated myocardial single photon emission computed tomography with technetium-99m tetrofosmin

    International Nuclear Information System (INIS)

    Kanna, Masahiko; Mitani, Isao; Nakamaru, Masashi; Shibuya, Ken; Takeda, Kazuyoshi; Asahina, Shigeru; Kitamura, Yutaka; Higuma, Kikuhiko; Ishii, Masao

    1998-01-01

    Simultaneous assessment of stress perfusion and rest function is possible with gated single photon emission computed tomography (SPECT) using stress injected technetium-99m ( 99m Tc) tetrofosmin (TF). The feasibility of dipyridamole stress electrocardiographic gated myocardial SPECT (GSPECT) with TF was examined as an alternative to conventional stress/rest imaging. Fifty-one patients underwent stress GSPECT. 740 MBq of TF was administered 3 min after dipyridamole infusion. GSPECT acquisition was performed one hour after the injection. Additional rest SPECT was performed on another day only in patients with abnormal perfusion on stress images. Perfusion and thickening were analyzed visually on 17 segments of the left ventricle. Percentage of wall thickening (%WT) was also calculated in 17 segments of the polar map. Thirty-two of 51 patients (63%) had normal stress perfusion and normal rest thickening. Nineteen of 51 patients (37%) had abnormal perfusion on stress images. Among 157 abnormal perfusion segments of the 19 patients, 139 segments (89%) had thickening and the rest (11%) had no thickening. %WT was higher in the reversible segments with or without thickening. There was better agreement for the identification of normal segments and the presence of reversibility between stress GSPECT and the conventional stress/rest study in patients without previous myocardial infarction than in those with previous myocardial infarction (89% vs 79%). These results suggest that stress GSPECT may substitute for conventional stress/rest perfusion study in patients without previous myocardial infarction, allowing shorter examination time and lower cost. However, stress GSPECT does not replace the need for rest perfusion study in patients with previous myocardial infarction, because of underestimation of viability, but %WT may eliminate this underestimation. (author)

  16. Dual Atrioventricular Nodal Pathways Physiology: A Review of Relevant Anatomy, Electrophysiology, and Electrocardiographic Manifestations

    Directory of Open Access Journals (Sweden)

    Bhalaghuru Chokkalingam Mani, MD

    2014-01-01

    Full Text Available More than half a century has passed since the concept of dual atrioventricular (AV nodal pathways physiology was conceived. Dual AV nodal pathways have been shown to be responsible for many clinical arrhythmia syndromes, most notably AV nodal reentrant tachycardia. Although there has been a considerable amount of research on this topic, the subject of dual AV nodal pathways physiology remains heavily debated and discussed. Despite advances in understanding arrhythmia mechanisms and the widespread use of invasive electrophysiologic studies, there is still disagreement on the anatomy and physiology of the AV node that is the basis of discontinuous antegrade AV conduction. The purpose of this paper is to review the concept of dual AV nodal pathways physiology and its varied electrocardiographic manifestations.

  17. A dual function fusion protein of Herpes simplex virus type 1 thymidine kinase and firefly luciferase for noninvasive in vivo imaging of gene therapy in malignant glioma.

    Science.gov (United States)

    Söling, Ariane; Theiss, Christian; Jungmichel, Stephanie; Rainov, Nikolai G

    2004-08-04

    BACKGROUND: Suicide gene therapy employing the prodrug activating system Herpes simplex virus type 1 thymidine kinase (HSV-TK)/ ganciclovir (GCV) has proven to be effective in killing experimental brain tumors. In contrast, glioma patients treated with HSV-TK/ GCV did not show significant treatment benefit, most likely due to insufficient transgene delivery to tumor cells. Therefore, this study aimed at developing a strategy for real-time noninvasive in vivo monitoring of the activity of a therapeutic gene in brain tumor cells. METHODS: The HSV-TK gene was fused to the firefly luciferase (Luc) gene and the fusion construct HSV-TK-Luc was expressed in U87MG human malignant glioma cells. Nude mice with subcutaneous gliomas stably expressing HSV-TK-Luc were subjected to GCV treatment and tumor response to therapy was monitored in vivo by serial bioluminescence imaging. Bioluminescent signals over time were compared with tumor volumes determined by caliper. RESULTS: Transient and stable expression of the HSV-TK-Luc fusion protein in U87MG glioma cells demonstrated close correlation of both enzyme activities. Serial optical imaging of tumor bearing mice detected in all cases GCV induced death of tumor cells expressing the fusion protein and proved that bioluminescence can be reliably used for repetitive and noninvasive quantification of HSV-TK/ GCV mediated cell kill in vivo. CONCLUSION: This approach may represent a valuable tool for the in vivo evaluation of gene therapy strategies for treatment of malignant disease.

  18. Photoacoustic imaging of lymphatic pumping

    Science.gov (United States)

    Forbrich, Alex; Heinmiller, Andrew; Zemp, Roger J.

    2017-10-01

    The lymphatic system is responsible for fluid homeostasis and immune cell trafficking and has been implicated in several diseases, including obesity, diabetes, and cancer metastasis. Despite its importance, the lack of suitable in vivo imaging techniques has hampered our understanding of the lymphatic system. This is, in part, due to the limited contrast of lymphatic fluids and structures. Photoacoustic imaging, in combination with optically absorbing dyes or nanoparticles, has great potential for noninvasively visualizing the lymphatic vessels deep in tissues. Multispectral photoacoustic imaging is capable of separating the components; however, the slow wavelength switching speed of most laser systems is inadequate for imaging lymphatic pumping without motion artifacts being introduced into the processed images. We investigate two approaches for visualizing lymphatic processes in vivo. First, single-wavelength differential photoacoustic imaging is used to visualize lymphatic pumping in the hindlimb of a mouse in real time. Second, a fast-switching multiwavelength photoacoustic imaging system was used to assess the propulsion profile of dyes through the lymphatics in real time. These approaches may have profound impacts in noninvasively characterizing and investigating the lymphatic system.

  19. SU-E-J-96: Multi-Axis Dose Accumulation of Noninvasive Image-Guided Breast Brachytherapy Through Biomechanical Modeling of Tissue Deformation Using the Finite Element Method

    International Nuclear Information System (INIS)

    Rivard, MJ; Ghadyani, HR; Bastien, AD; Lutz, NN; Hepel, JT

    2015-01-01

    Purpose: Noninvasive image-guided breast brachytherapy delivers conformal HDR Ir-192 brachytherapy treatments with the breast compressed, and treated in the cranial-caudal and medial-lateral directions. This technique subjects breast tissue to extreme deformations not observed for other disease sites. Given that, commercially-available software for deformable image registration cannot accurately co-register image sets obtained in these two states, a finite element analysis based on a biomechanical model was developed to deform dose distributions for each compression circumstance for dose summation. Methods: The model assumed the breast was under planar stress with values of 30 kPa for Young’s modulus and 0.3 for Poisson’s ratio. Dose distributions from round and skin-dose optimized applicators in cranial-caudal and medial-lateral compressions were deformed using 0.1 cm planar resolution. Dose distributions, skin doses, and dose-volume histograms were generated. Results were examined as a function of breast thickness, applicator size, target size, and offset distance from the center. Results: Over the range of examined thicknesses, target size increased several millimeters as compression thickness decreased. This trend increased with increasing offset distances. Applicator size minimally affected target coverage, until applicator size was less than the compressed target size. In all cases, with an applicator larger or equal to the compressed target size, > 90% of the target covered by > 90% of the prescription dose. In all cases, dose coverage became less uniform as offset distance increased and average dose increased. This effect was more pronounced for smaller target-applicator combinations. Conclusions: The model exhibited skin dose trends that matched MC-generated benchmarking results and clinical measurements within 2% over a similar range of breast thicknesses and target sizes. The model provided quantitative insight on dosimetric treatment variables over

  20. SU-E-J-96: Multi-Axis Dose Accumulation of Noninvasive Image-Guided Breast Brachytherapy Through Biomechanical Modeling of Tissue Deformation Using the Finite Element Method

    Energy Technology Data Exchange (ETDEWEB)

    Rivard, MJ [Tufts University School of Medicine, Boston, MA (United States); Ghadyani, HR [SUNY Farmingdale State College, Farmingdale, NY (United States); Bastien, AD; Lutz, NN [Univeristy Massachusetts Lowell, Lowell, MA (United States); Hepel, JT [Rhode Island Hospital, Providence, RI (United States)

    2015-06-15

    Purpose: Noninvasive image-guided breast brachytherapy delivers conformal HDR Ir-192 brachytherapy treatments with the breast compressed, and treated in the cranial-caudal and medial-lateral directions. This technique subjects breast tissue to extreme deformations not observed for other disease sites. Given that, commercially-available software for deformable image registration cannot accurately co-register image sets obtained in these two states, a finite element analysis based on a biomechanical model was developed to deform dose distributions for each compression circumstance for dose summation. Methods: The model assumed the breast was under planar stress with values of 30 kPa for Young’s modulus and 0.3 for Poisson’s ratio. Dose distributions from round and skin-dose optimized applicators in cranial-caudal and medial-lateral compressions were deformed using 0.1 cm planar resolution. Dose distributions, skin doses, and dose-volume histograms were generated. Results were examined as a function of breast thickness, applicator size, target size, and offset distance from the center. Results: Over the range of examined thicknesses, target size increased several millimeters as compression thickness decreased. This trend increased with increasing offset distances. Applicator size minimally affected target coverage, until applicator size was less than the compressed target size. In all cases, with an applicator larger or equal to the compressed target size, > 90% of the target covered by > 90% of the prescription dose. In all cases, dose coverage became less uniform as offset distance increased and average dose increased. This effect was more pronounced for smaller target-applicator combinations. Conclusions: The model exhibited skin dose trends that matched MC-generated benchmarking results and clinical measurements within 2% over a similar range of breast thicknesses and target sizes. The model provided quantitative insight on dosimetric treatment variables over

  1. Arrhythmogenic right ventricular cardiomyopathy: contribution of different electrocardiographic techniques.

    Science.gov (United States)

    Moreira, Davide; Delgado, Anne; Marmelo, Bruno; Correia, Emanuel; Gama, Pedro; Pipa, João; Nunes, Luís; Santos, Oliveira

    2014-04-01

    Arrhythmogenic right ventricular cardiomyopathy, also known as arrhythmogenic right ventricular dysplasia, is a condition in which myocardium is replaced by fibrous or fibrofatty tissue, predominantly in the right ventricle. It is clinically characterized by potentially lethal ventricular arrhythmias, and is a leading cause of sudden cardiac death. Its prevalence is not known exactly but is estimated at approximately 1:5000 in the adult population. Diagnosis can be on the basis of structural and functional alterations of the right ventricle, electrocardiographic abnormalities (including depolarization and repolarization alterations and ventricular arrhythmias) and family history. Diagnostic criteria facilitate the recognition and interpretation of non-specific clinical features of this disease. The authors present a case in which the diagnosis of arrhythmogenic right ventricular cardiomyopathy was prompted by the suspicion of right ventricular disease on transthoracic echocardiography. This was confirmed by detection of epsilon waves on analysis of the ECG, which generally go unnoticed but in this case were the key to the diagnosis. Their presence was also shown by non-conventional ECG techniques such as modified Fontaine ECG. The course of the disease culminated in the occurrence of ventricular tachycardia, which prompted placement of an implantable cardioverter-defibrillator. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  2. Effect of pregnancy and correlation of weight and heart rate with electrocardiographic parameters in the American Miniature Horse

    Directory of Open Access Journals (Sweden)

    B.P. Santarosa

    2016-06-01

    Full Text Available ABSTRACT There are studies on electrocardiogram (ECG in several breeds of horses, which highlights the growing importance of cardiology in this species. But few authors have addressed the influence of pregnancy on the cardiac physiology of the mare, and specifically, there are no studies on the Mini-horse breed, as well as no correlation of body weight (BW and heart rate (HR with electrocardiographic parameters in this breed. The aims of this study were to determine the effects of pregnancy on ECG parameters and to examine the relationships between these variables and body weight (BW and heart rate (HR. A total of 203 animals were used, including 143 females (66 pregnant and 60 males. Electrocardiographic examinations were performed by computerized electrocardiogram (TEB, and the parameters were evaluated in six leads in the frontal plane (Lead I, II, III, aVR, aVL and aVF and base-apex (BA. BW was inversely proportional to HR, which in turn showed an inverse relationship with the duration of the P-wave and the PR and QT intervals. The P-wave amplitude (lead II was higher in pregnant animals than in non-pregnant animals. The effect of reproductive status should be monitored by ECG throughout the entire gestational period. The 66 pregnant mares in this study were examined during the first third of their pregnancies, thus, few differences were observed between pregnant and non-pregnant animals.

  3. Noninvasive neuromodulation in migraine and cluster headache.

    Science.gov (United States)

    Starling, Amaal

    2018-06-01

    The purpose of this narrative review is to provide an overview of the currently available noninvasive neuromodulation devices for the treatment of migraine and cluster headache. Over the last decade, several noninvasive devices have undergone development and clinical trials to evaluate efficacy and safety. Based on this body of work, single-pulse transcranial magnetic stimulation, transcutaneous supraorbital neurostimulation, and noninvasive vagal nerve stimulation devices have been cleared by the United States Food and Drug Administration and are available for clinical use for the treatment of primary headache disorders. Overall, these novel noninvasive devices appear to be safe, well tolerated, and have demonstrated promising results in clinical trials in both migraine and cluster headache. This narrative review will provide a summary and update of the proposed mechanisms of action, evidence, safety, and future directions of various currently available modalities of noninvasive neuromodulation for the treatment of migraine and cluster headache.

  4. Fluorescence imaging with near-infrared light: new technological advances that enable in vivo molecular imaging

    International Nuclear Information System (INIS)

    Ntziachristos, Vasilis; Bremer, Christoph; Weissleder, Ralph

    2003-01-01

    A recent development in biomedical imaging is the non-invasive mapping of molecular events in intact tissues using fluorescence. Underpinning to this development is the discovery of bio-compatible, specific fluorescent probes and proteins and the development of highly sensitive imaging technologies for in vivo fluorescent detection. Of particular interest are fluorochromes that emit in the near infrared (NIR), a spectral window, whereas hemoglobin and water absorb minimally so as to allow photons to penetrate for several centimetres in tissue. In this review article we concentrate on optical imaging technologies used for non-invasive imaging of the distribution of such probes. We illuminate the advantages and limitations of simple photographic methods and turn our attention to fluorescence-mediated molecular tomography (FMT), a technique that can three-dimensionally image gene expression by resolving fluorescence activation in deep tissues. We describe theoretical specifics, and we provide insight into its in vivo capacity and the sensitivity achieved. Finally, we discuss its clinical feasibility. (orig.)

  5. Noninvasive evaluation of sympathetic nervous system in human heart by positron emission tomography

    International Nuclear Information System (INIS)

    Schwaiger, M.; Kalff, V.; Rosenspire, K.; Haka, M.S.; Molina, E.; Hutchins, G.D.; Deeb, M.; Wolfe, E. Jr.; Wieland, D.M.

    1990-01-01

    The noninvasive functional characterization of the cardiac sympathetic nervous system by imaging techniques may provide important pathophysiological information in various cardiac disease states. Hydroxyephedrine labeled with carbon 11 has been developed as a new catecholamine analogue to be used in the in vivo evaluation of presynaptic adrenergic nerve terminals by positron emission tomography (PET). To determine the feasibility of this imaging approach in the human heart, six normal volunteers and five patients with recent cardiac transplants underwent dynamic PET imaging after intravenous injection of 20 mCi [11C]hydroxyephedrine. Blood and myocardial tracer kinetics were assessed using a regions-of-interest approach. In normal volunteers, blood 11C activity cleared rapidly, whereas myocardium retained 11C activity with a long tissue half-life. Relative tracer retention in the myocardium averaged 79 +/- 31% of peak activity at 60 minutes after tracer injection. The heart-to-blood 11C activity ratio exceeded 6:1 as soon as 30 minutes after tracer injection, yielding excellent image quality. Little regional variation of tracer retention was observed, indicating homogeneous sympathetic innervation throughout the left ventricle. In the transplant recipients, myocardial [11C]hydroxyephedrine retention at 60 minutes was significantly less (-82%) than that of normal volunteers, indicating only little non-neuronal binding of the tracer in the denervated human heart. Thus, [11C]hydroxyephedrine, in combination with dynamic PET imaging, allows the noninvasive delineation of myocardial adrenergic nerve terminals. Tracer kinetic modeling may permit quantitative assessment of myocardial catecholamine uptake, which will in turn provide insights into the effects of various disease processes on the neuronal integrity of the heart

  6. Rapid noninvasive detection of experimental atherosclerotic lesions with novel 99mTc-labeled diadenosine tetraphosphates

    Science.gov (United States)

    Elmaleh, David R.; Narula, Jagat; Babich, John W.; Petrov, Artiom; Fischman, Alan J.; Khaw, Ban-An; Rapaport, Eliezer; Zamecnik, Paul C.

    1998-01-01

    The development of a noninvasive imaging procedure for identifying atherosclerotic lesions is extremely important for the clinical management of patients with coronary artery and peripheral vascular disease. Although numerous radiopharmaceuticals have been proposed for this purpose, none has demonstrated the diagnostic accuracy required to replace invasive angiography. In this report, we used the radiolabeled purine analog, 99mTc diadenosine tetraphosphate (Ap4A; AppppA, P1,P4-di(adenosine-5′)-tetraphosphate) and its analogue 99mTc AppCHClppA for imaging experimental atherosclerotic lesions in New Zealand White rabbits. Serial gamma camera images were obtained after intravenous injection of the radiolabeled dinucleotides. After acquiring the final images, the animals were sacrificed, ex vivo images of the aortas were recorded, and biodistribution was measured. 99mTc-Ap4A and 99mTc AppCHClppA accumulated rapidly in atherosclerotic abdominal aorta, and lesions were clearly visible within 30 min after injection in all animals that were studied. Both radiopharmaceuticals were retained in the lesions for 3 hr, and the peak lesion to normal vessel ratio was 7.4 to 1. Neither of the purine analogs showed significant accumulation in the abdominal aorta of normal (control) rabbits. The excised aortas showed lesion patterns that were highly correlated with the in vivo and ex vivo imaging results. The present study demonstrates that purine receptors are up-regulated in experimental atherosclerotic lesions and 99mTc-labeled purine analogs have potential for rapid noninvasive detection of plaque formation. PMID:9435254

  7. Non-invasive assessment of gastric activity

    International Nuclear Information System (INIS)

    Smallwood, R.H.; Brown, B.H.

    1983-01-01

    There have been many suggestions for the routine clinical use of the electro-enterogram, but with the exception of the reported usage in the USSR no significant penetration into medical practice has been reported elsewhere. Amongst the many suggestions have been the possible application of electrical stimulation via surface electrodes to overcome post-operative inhibition of intestinal electrical activity, which can be recorded via surface electrodes. Gastric emptying studies have shown that duodenal ulceration is associated with changes in the rate and pattern of emptying of solid meals. Identifiable patterns in the electro-gastrogram following a metal might have diagnostic application. There is some evidence of correlations of electrical activity and pathology in the large intestine. In the colon diverticular disease has been shown to change the frequency content of the slow wave electrical activity and there is some evidence that this might be recorded from surface electrodes. A major obstacle to progress remains the inability to relate non-invasive recordings to intestinal motility. The best hope may be the use of direct and yet non-invasive methods of obtaining motility and in this context real-time ultrasound imaging is probably the most promising technique. The electro-gastrogram has certainly been shown to allow recording of gastric slow wave activity and there is a reasonable hope that further methods of analysis will allow inferential information on motility to be obtained. The following section makes brief mention of these techniques

  8. Triangulation of the monophasic action potential causes flattening of the electrocardiographic T-wave

    DEFF Research Database (Denmark)

    Bhuiyan, Tanveer Ahmed; Graff, Claus; Thomsen, Morten Bækgaard

    2012-01-01

    of the action potential under the effect of the IKr blocker sertindole and associated these changes to concurrent changes in the morphology of electrocardiographic T-waves in dogs. We show that, under the effect of sertindole, the peak changes in the morphology of action potentials occur at time points similar......It has been proposed that triangulation on the cardiac action potential manifests as a broadened, more flat and notched T-wave on the ECG but to what extent such morphology characteristics are indicative of triangulation is more unclear. In this paper, we have analyzed the morphological changes...... to those observed for the peak changes in T-wave morphology on the ECG. We further show that the association between action potential shape and ECG shape is dose-dependent and most prominent at the time corresponding to phase 3 of the action potential....

  9. Clinical applications of perfluorocarbon nanoparticles for molecular imaging and targeted therapeutics.

    Science.gov (United States)

    Tran, Trung D; Caruthers, Shelton D; Hughes, Michael; Marsh, John N; Cyrus, Tillmann; Winter, Patrick M; Neubauer, Anne M; Wickline, Samuel A; Lanza, Gregory M

    2007-01-01

    Molecular imaging is a novel tool that has allowed non-invasive diagnostic imaging to transition from gross anatomical description to identification of specific tissue epitopes and observation of biological processes at the cellular level. This technique has been confined to the field of nuclear imaging; however, recent advances in nanotechnology have extended this research to include ultrasound (US) and magnetic resonance (MR) imaging. The exploitation of nanotechnology for MR and US molecular imaging has generated several candidate contrast agents. One multimodality platform, targeted perfluorocarbon (PFC) nanoparticles, is useful for noninvasive detection with US and MR, targeted drug delivery, and quantification.

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  11. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... imaging of the abdomen is a safe, noninvasive test that uses sound waves to produce a clear ...

  12. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  13. A fundamental numerical analysis for noninvasive thermometry integrated in a heating applicator based on the reentrant cavity

    International Nuclear Information System (INIS)

    Ohwada, Hiroshi; Ishihara, Yasutoshi

    2010-01-01

    To improve the efficacy of hyperthermia treatment, a novel method of noninvasive measurement of body temperature change is proposed. The proposed technology, thermometry, is based on changes in the electromagnetic field distribution inside the heating applicator with temperature changes and the temperature dependence of the dielectric constant. In addition, an image of the temperature change distribution inside a body is reconstructed by applying a computed tomography (CT) algorithm. The proposed thermometry method can serve as a possible noninvasive method to monitor the temperature change distribution inside the body without the use of enormous thermometers such as in the case of magnetic resonance imaging (MRI). Furthermore, this temperature monitoring method can be easily combined with a heating applicator based on a cavity resonator, and the novel integrated treatment system can possibly be used to treat cancer effectively while noninvasively monitoring the heating effect. In this paper, the phase change distributions of the electromagnetic field with temperature changes are simulated by numerical analysis using the finite difference time domain (FDTD) method. Moreover, to estimate the phase change distributions inside a target body, the phase change distributions with temperature changes are reconstructed by a filtered back-projection. In addition, the reconstruction accuracy of the converted temperature change distribution from the phase change is evaluated. (author)

  14. Non-invasive brain stimulation in the detection of deception: scientific challenges and ethical consequences.

    Science.gov (United States)

    Luber, Bruce; Fisher, Carl; Appelbaum, Paul S; Ploesser, Marcus; Lisanby, Sarah H

    2009-01-01

    Tools for noninvasive stimulation of the brain, such as transcranial magnetic stimulation (TMS) and transcranial direct current stimulation (tDCS), have provided new insights in the study of brain-behavior relationships due to their ability to directly alter cortical activity. In particular, TMS and tDCS have proven to be useful tools for establishing causal relationships between behavioral and brain imaging measures. As such, there has been interest in whether these tools may represent novel technologies for deception detection by altering a person's ability to engage brain networks involved in conscious deceit. Investigation of deceptive behavior using noninvasive brain stimulation is at an early stage. Here we review the existing literature on the application of noninvasive brain stimulation in the study of deception. Whether such approaches could be usefully applied to the detection of deception by altering a person's ability to engage brain networks involved in conscious deceit remains to be validated. Ethical and legal consequences of the development of such a technology are discussed. Copyright 2009 John Wiley & Sons, Ltd.

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  16. Diagnostic imaging in medicine. 2. ed.

    International Nuclear Information System (INIS)

    Reba, R.C.; Goodenough, D.J.

    1984-01-01

    This book describes to practitioners the evolutionary progression of new non-invasive diagnostic imaging techniques. The utility of the procedures is also described in a series of state-of-the-art lectures given by outstanding international clinical investigators from NATO countries. Subjects of the papers include the following: advances in source and detector technology, acoustical imaging, NMR and microwave imaging, positron and single photon emission tomography, digital radiography and image processing and display techniques. Fundamental papers describing the theory of non-invasive procedures are included along with papers describing clinical examinations. Examples of utility and studies of diseases of the abdomen and pelvis, heart and lung, and central nervous system are included. Cost-effective and cost-benefit assessment of the new high technology procedures, as well as the use of diagnostic imaging techniques in developing countries are also presented. An index of leading topics completes the volume. (orig.)

  17. Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: in vivo results in human muscle

    DEFF Research Database (Denmark)

    De Poorter, J; De Wagter, C; De Deene, Y

    1995-01-01

    The noninvasive thermometry method is based on the temperature dependence of the proton resonance frequency (PRF). High-quality temperature images can be obtained from phase information of standard gradient-echo sequences with an accuracy of 0.2 degrees C in phantoms. This work was focused on the...

  18. Noninvasive Multimodality Imaging of the Tumor Microenvironment: Registered Dynamic Magnetic Resonance Imaging and Positron Emission Tomography Studies of a Preclinical Tumor Model of Tumor Hypoxia

    Directory of Open Access Journals (Sweden)

    HyungJoon Cho

    2009-03-01

    Full Text Available In vivo knowledge of the spatial distribution of viable, necrotic, and hypoxic areas can provide prognostic information about the risk of developing metastases and regional radiation sensitivity and may be used potentially for localized dose escalation in radiation treatment. In this study, multimodality in vivo magnetic resonance imaging (MRI and positron emission tomography (PET imaging using stereotactic fiduciary markers in the Dunning R3327AT prostate tumor were performed, focusing on the relationship between dynamic contrast-enhanced (DCE MRI using Magnevist (Gd-DTPA and dynamic 18F-fluoromisonidazole (18F-Fmiso PET. The noninvasive measurements were verified using tumor tissue sections stained for hematoxylin/eosin and pimonidazole. To further validate the relationship between 18F-Fmiso and pimonidazole uptake, 18F digital autoradiography was performed on a selected tumor and compared with the corresponding pimonidazole-stained slices. The comparison of Akep values (kep = rate constant of movement of Gd-DTPA between the interstitial space and plasma and A = amplitude in the two-compartment model (Hoffmann U, Brix G, Knopp MV, Hess T and Lorenz WJ (1995. Magn Reson Med 33, 506– 514 derived from DCE-MRI studies and from early 18F-Fmiso uptake PET studies showed that tumor vasculature is a major determinant of early 18F-Fmiso uptake. A negative correlation between the spatial map of Akep and the slope map of late (last 1 hour of the dynamic PET scan 18F-Fmiso uptake was observed. The relationships between DCE-MRI and hematoxylin/eosin slices and between 18F-Fmiso PET and pimonidazole slices confirm the validity of MRI/PET measurements to image the tumor microenvironment and to identify regions of tumor necrosis, hypoxia, and well-perfused tissue.

  19. The pacing stress test: thallium-201 myocardial imaging after atrial pacing. Diagnostic value in detecting coronary artery disease compared with exercise testing

    International Nuclear Information System (INIS)

    Heller, G.V.; Aroesty, J.M.; Parker, J.A.; McKay, R.G.; Silverman, K.J.; Als, A.V.; Come, P.C.; Kolodny, G.M.; Grossman, W.

    1984-01-01

    Many patients suspected of having coronary artery disease are unable to undergo adequate exercise testing. An alternate stress, pacing tachycardia, has been shown to produce electrocardiographic changes that are as sensitive and specific as those observed during exercise testing. To compare thallium-201 imaging after atrial pacing stress with thallium imaging after exercise stress, 22 patients undergoing cardiac catheterization were studied with both standard exercise thallium imaging and pacing thallium imaging. Positive ischemic electrocardiographic changes (greater than 1 mm ST segment depression) were noted in 11 of 16 patients with coronary artery disease during exercise, and in 15 of the 16 patients during atrial pacing. One of six patients with normal or trivial coronary artery disease had a positive electrocardiogram with each test. Exercise thallium imaging was positive in 13 of 16 patients with coronary artery disease compared with 15 of 16 patients during atrial pacing. Three of six patients without coronary artery disease had a positive scan with exercise testing, and two of these same patients developed a positive scan with atrial pacing. Of those patients with coronary artery disease and an abnormal scan, 85% showed redistribution with exercise testing compared with 87% during atrial pacing. Segment by segment comparison of thallium imaging after either atrial pacing or exercise showed that there was a good correlation of the location and severity of the thallium defects (r . 0.83, p . 0.0001, Spearman rank correlation). It is concluded that the location and presence of both fixed and transient thallium defects after atrial pacing are closely correlated with the findings after exercise testing

  20. Diagnostic imaging of the pancreas

    International Nuclear Information System (INIS)

    Araki, Tsutomu; Itai, Yuji

    1981-01-01

    Diagnostic imaging of the pancreas, ultrasonography (US), computed tomography (CT), radionuclide (RN) scintigraphy, angiography, and endoscopic retrograde pancreaticography (ERP). First three noninvasive methods, were the most effective to diagnose psudo-cyst or cystoadenoma. Especially, CT gives the clear image of inflammation and shows pancreatic stones and calcification, with high sensitivity. As for pancreatic carcinomas there was no noninvasive methods to apply at an early stage. In order to diagnose the cancer the combination of angiography and ERP was preferable. The problem was how to select the candidates for the investigation of combined method out of the patients with negative CT or US. (Tsunoda, M.)

  1. New trend in non-invasive prenatal diagnosis.

    Science.gov (United States)

    Ferrari, M; Carrera, P; Lampasona, V; Galbiati, S

    2015-12-07

    The presence of fetal DNA in maternal plasma represents a source of genetic material which can be obtained non-invasively. To date, the translation of noninvasive prenatal diagnosis from research into clinical practice has been rather fragmented, and despite the advances in improving the analytical sensitivity of methods, distinguishing between fetal and maternal sequences remains very challenging. Thus, the field of noninvasive prenatal diagnosis of genetic diseases has yet to attain a routine application in clinical diagnostics. On the contrary, fetal sex determination in pregnancies at high risk of sex-linked disorders, tests for fetal RHD genotyping and non-invasive assessment of chromosomal aneuploidies are now available worldwide. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Statistical model for OCT image denoising

    KAUST Repository

    Li, Muxingzi; Idoughi, Ramzi; Choudhury, Biswarup; Heidrich, Wolfgang

    2017-01-01

    Optical coherence tomography (OCT) is a non-invasive technique with a large array of applications in clinical imaging and biological tissue visualization. However, the presence of speckle noise affects the analysis of OCT images and their diagnostic

  3. Electrocardiographic intricacies clarified by echocardiography--should the electrocardiogram be interpreted echocardiographically?

    Science.gov (United States)

    Ker, James

    2012-07-12

    During the past century the electrocardiogram (ECG) has established itself as an integral part of the cardiovascular examination. Since the first direct recordings of cardiac potentials by Waller in 1887, to the invention of the string galvanometer by Willem Einthoven in 1901, to use in the clinic by 1910, the electrocardiogram has become the most widely used clinical tool in the diagnosis of virtually every type of heart disease. Currently up to 20 million ECGs are performed annually in the United States alone. However, in this era of readily available echocardiography, an important caveat in the interpretation of the electrocardiogram has emerged: variants of intracardiac structures which might mimic disease on the ECG. In this perspective various structural variants of intracardiac structures, specifically variants of papillary muscles and subaortic muscular bands, will be shown, together with their associated electrocardiographic changes, mimicking disease. It is concluded that in this era of readily available echocardiography, the electrocardiogram should be interpreted echocardiographically in instances where intricate variations are seen on the surface electrocardiogram. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  4. Non-invasive determination of the complete elastic moduli of spider silks

    Science.gov (United States)

    Koski, Kristie J.; Akhenblit, Paul; McKiernan, Keri; Yarger, Jeffery L.

    2013-03-01

    Spider silks possess nature’s most exceptional mechanical properties, with unrivalled extensibility and high tensile strength. Unfortunately, our understanding of silks is limited because the complete elastic response has never been measured—leaving a stark lack of essential fundamental information. Using non-invasive, non-destructive Brillouin light scattering, we obtain the entire stiffness tensors (revealing negative Poisson’s ratios), refractive indices, and longitudinal and transverse sound velocities for major and minor ampullate spider silks: Argiope aurantia, Latrodectus hesperus, Nephila clavipes, Peucetia viridans. These results completely quantify the linear elastic response for all possible deformation modes, information unobtainable with traditional stress-strain tests. For completeness, we apply the principles of Brillouin imaging to spatially map the elastic stiffnesses on a spider web without deforming or disrupting the web in a non-invasive, non-contact measurement, finding variation among discrete fibres, junctions and glue spots. Finally, we provide the stiffness changes that occur with supercontraction.

  5. Electrocardiographic exam in female spotted pacas (Cuniculus paca

    Directory of Open Access Journals (Sweden)

    Ricardo A.R. Uscategui

    2016-06-01

    Full Text Available Abstract: Considering the limited physiological information available on neotropical rodents and the importance of this information for pathophysiological and conservation studies of these species, the aim of this study was to evaluate the cardiac electric physiology of healthy captivity spotted pacas (Cuniculus paca under chemical restraint, due to wild nature of these animals. Eleven adult female pacas were evaluated by blood count and biochemical dosage to rule out any associate disease. Each animal was evaluated in three periods every 15 days. After chemical restraint with intramuscular midazolam 0.5mg/kg and ketamine 25mg/kg, animals were subjected to a computerized electrocardiogram, where bipolar (DI, DII and DIII and augmented unipolar leads (aVR, aVL, aVF were obtained. Descriptive statistics were calculated for each parameter and built the confidence interval (CI at significance level of 95%. The electrocardiographic examination was performed without difficult. ECG tracing in DII represents a QRS complex with positive polarity, preceded by a P wave of the same polarity and proceeded by T wave of variable polarity. Heart rate mean was 150±17 bpm, and cardiac electrical axis 33.4±21.9°. All animals showed sinusal rhythm. The ECG recording technique associated with chemical restraint was well tolerated, allowing quick acquisition of reliable ECG tracings with high repeatability, which produced sufficient results to determine the heart rhythm and suggest measures of ECG complexes duration and amplitude.

  6. Progress on molecular imaging

    International Nuclear Information System (INIS)

    Chen Quan; Zhang Yongxue

    2011-01-01

    Molecular imaging is a new era of medical imaging,which can non-invasively monitor biological processes at the cellular and molecular level in vivo, including molecular imaging of nuclear medicine, magnetic resonance molecular imaging, ultrasound molecular imaging,optical molecular imaging and molecular imaging with X-ray. Recently, with the development of multi-subjects amalgamation, multimodal molecular imaging technology has been applied in clinical imaging, such as PET-CT and PET-MRI. We believe that with development of molecular probe and multi-modal imaging, more and more molecular imaging techniques will be applied in clinical diagnosis and treatment. (authors)

  7. Noninvasive quantitation of human liver steatosis using magnetic resonance and bioassay methods

    Energy Technology Data Exchange (ETDEWEB)

    D' Assignies, Gaspard; Ruel, Martin; Khiat, Abdesslem; Lepanto, Luigi; Kauffmann, Claude; Tang, An [Centre Hospitalier de l' Universite de Montreal (CHUM), Departement de Radiologie, Montreal, Quebec (Canada); Chagnon, Miguel [Universite de Montreal (UDEM), Departement de Mathematiques et de Statistique, Montreal, Quebec (Canada); Gaboury, Louis [Centre Hospitalier de l' Universite de Montreal (CHUM), Departement d' Anatomo-Pathologie, Montreal, Quebec (Canada); Boulanger, Yvan [Centre Hospitalier de l' Universite de Montreal (CHUM), Departement de Radiologie, Montreal, Quebec (Canada); Hopital Saint-Luc du CHUM, Departement de Radiologie, Montreal, Quebec (Canada)

    2009-08-15

    The purpose was to evaluate the ability of three magnetic resonance (MR) techniques to detect liver steatosis and to determine which noninvasive technique (MR, bioassays) or combination of techniques is optimal for the quantification of hepatic fat using histopathology as a reference. Twenty patients with histopathologically proven steatosis and 24 control subjects underwent single-voxel proton MR spectroscopy (MRS; 3 voxels), dual-echo in phase/out of phase MR imaging (DEI) and diffusion-weighted MR imaging (DWI) examinations of the liver. Blood or urine bioassays were also performed for steatosis patients. Both MRS and DEI data allowed to detect steatosis with a high sensitivity (0.95 for MRS; 1 for DEI) and specificity (1 for MRS; 0.875 for DEI) but not DWI. Strong correlations were found between fat fraction (FF) measured by MRS, DEI and histopathology segmentation as well as with low density lipoprotein (LDL) and cholesterol concentrations. A Bland-Altman analysis showed a good agreement between the FF measured by MRS and DEI. Partial correlation analyses failed to improve the correlation with segmentation FF when MRS or DEI data were combined with bioassay results. Therefore, FF from MRS or DEI appear to be the best parameters to both detect steatosis and accurately quantify fat liver noninvasively. (orig.)

  8. Noninvasive Quantification of Retinal Microglia Using Widefield Autofluorescence Imaging.

    Science.gov (United States)

    Kokona, Despina; Schneider, Nadia; Giannakaki-Zimmermann, Helena; Jovanovic, Joel; Ebneter, Andreas; Zinkernagel, Martin

    2017-04-01

    To validate widefield autofluorescence (AF) in vivo imaging of the retina in mice expressing green fluorescent protein (gfp) in microglia, and to monitor retinal microglia reconstitution in vivo after lethal irradiation and bone marrow transplantation. Transgenic Cx3cr1gfp/gfp and wildtype Balb/c mice were used in this study. A confocal scanning laser ophthalmoscope was used for AF imaging with a 55° and a widefield 102° lens. Intrasession reproducibility was assessed for each lens. To investigate reconstitution in vivo, bone marrow from Cx3cr1gfp/gfp mice was used to rescue lethally irradiated wildtype mice. Data were compared to confocal microscopy of retinal flat mounts. Both the 55° and the 102° lens produced high resolution images of retinal microglia with similar microglia density. However, compared to the 55° lens, the widefield 102° lens captured approximately 3.6 times more microglia cells (1515 ± 123 cells versus 445 ± 76 cells [mean ± SD], for 102° and 55°, respectively, P < 0.001). No statistical difference in the number of gfp positive cells within corresponding areas was observed within the same imaging session. Imaging of microglia reconstitution showed a similar time course compared to flat mount preparations with an excellent correlation between microglia cell numbers in AF and gfp-stained flat mounts (R = 0.92, P < 0.0001). Widefield AF imaging of mice with gfp expressing microglia can be used to quantify retinal microglia. In vivo microglia counts corresponded very well with ex vivo counts on retinal flat mounts. As such, AF imaging can largely replace ex vivo quantification.

  9. Non-invasive Markers of Liver Fibrosis: Adjuncts or Alternatives to Liver Biopsy?

    Science.gov (United States)

    Chin, Jun L.; Pavlides, Michael; Moolla, Ahmad; Ryan, John D.

    2016-01-01

    Liver fibrosis reflects sustained liver injury often from multiple, simultaneous factors. Whilst the presence of mild fibrosis on biopsy can be a reassuring finding, the identification of advanced fibrosis is critical to the management of patients with chronic liver disease. This necessity has lead to a reliance on liver biopsy which itself is an imperfect test and poorly accepted by patients. The development of robust tools to non-invasively assess liver fibrosis has dramatically enhanced clinical decision making in patients with chronic liver disease, allowing a rapid and informed judgment of disease stage and prognosis. Should a liver biopsy be required, the appropriateness is clearer and the diagnostic yield is greater with the use of these adjuncts. While a number of non-invasive liver fibrosis markers are now used in routine practice, a steady stream of innovative approaches exists. With improvement in the reliability, reproducibility and feasibility of these markers, their potential role in disease management is increasing. Moreover, their adoption into clinical trials as outcome measures reflects their validity and dynamic nature. This review will summarize and appraise the current and novel non-invasive markers of liver fibrosis, both blood and imaging based, and look at their prospective application in everyday clinical care. PMID:27378924

  10. Biomechanics of subcellular structures by non-invasive Brillouin microscopy

    Science.gov (United States)

    Antonacci, Giuseppe; Braakman, Sietse

    2016-11-01

    Cellular biomechanics play a pivotal role in the pathophysiology of several diseases. Unfortunately, current methods to measure biomechanical properties are invasive and mostly limited to the surface of a cell. As a result, the mechanical behaviour of subcellular structures and organelles remains poorly characterised. Here, we show three-dimensional biomechanical images of single cells obtained with non-invasive, non-destructive Brillouin microscopy with an unprecedented spatial resolution. Our results quantify the longitudinal elastic modulus of subcellular structures. In particular, we found the nucleoli to be stiffer than both the nuclear envelope (p biomechanics and its role in pathophysiology.

  11. Noninvasive, three-dimensional full-field body sensor for surface deformation monitoring of human body in vivo

    Science.gov (United States)

    Chen, Zhenning; Shao, Xinxing; He, Xiaoyuan; Wu, Jialin; Xu, Xiangyang; Zhang, Jinlin

    2017-09-01

    Noninvasive, three-dimensional (3-D), full-field surface deformation measurements of the human body are important for biomedical investigations. We proposed a 3-D noninvasive, full-field body sensor based on stereo digital image correlation (stereo-DIC) for surface deformation monitoring of the human body in vivo. First, by applying an improved water-transfer printing (WTP) technique to transfer optimized speckle patterns onto the skin, the body sensor was conveniently and harmlessly fabricated directly onto the human body. Then, stereo-DIC was used to achieve 3-D noncontact and noninvasive surface deformation measurements. The accuracy and efficiency of the proposed body sensor were verified and discussed by considering different complexions. Moreover, the fabrication of speckle patterns on human skin, which has always been considered a challenging problem, was shown to be feasible, effective, and harmless as a result of the improved WTP technique. An application of the proposed stereo-DIC-based body sensor was demonstrated by measuring the pulse wave velocity of human carotid artery.

  12. Noninvasive Imaging of Retinal Morphology and Microvasculature in Obese Mice Using Optical Coherence Tomography and Optical Microangiography

    Science.gov (United States)

    Zhi, Zhongwei; Chao, Jennifer R.; Wietecha, Tomasz; Hudkins, Kelly L.; Alpers, Charles E.; Wang, Ruikang K.

    2014-01-01

    Purpose. To evaluate early diabetes-induced changes in retinal thickness and microvasculature in a type 2 diabetic mouse model by using optical coherence tomography (OCT)/optical microangiography (OMAG). Methods. Twenty-two-week-old obese (OB) BTBR mice (n = 10) and wild-type (WT) control mice (n = 10) were imaged. Three-dimensional (3D) data volumes were captured with spectral domain OCT using an ultrahigh-sensitive OMAG scanning protocol for 3D volumetric angiography of the retina and dense A-scan protocol for measurement of the total retinal blood flow (RBF) rate. The thicknesses of the nerve fiber layer (NFL) and that of the NFL to the inner plexiform layer (IPL) were measured and compared between OB and WT mice. The linear capillary densities within intermediate and deep capillary layers were determined by the number of capillaries crossing a 500-μm line. The RBF rate was evaluated using an en face Doppler approach. These quantitative measurements were compared between OB and WT mice. Results. The retinal thickness of the NFL to IPL was significantly reduced in OB mice (P < 0.01) compared to that in WT mice, whereas the NFL thickness between the two was unchanged. 3D depth-resolved OMAG angiography revealed the first in vivo 3D model of mouse retinal microcirculation. Although no obvious differences in capillary vessel densities of the intermediate and deep capillary layers were detected between normal and OB mice, the total RBF rate was significantly lower (P < 0.05) in OB mice than in WT mice. Conclusions. We conclude that OB BTBR mice have significantly reduced NFL–IPL thicknesses and total RBF rates compared with those of WT mice, as imaged by OCT/OMAG. OMAG provides an unprecedented capability for high-resolution depth-resolved imaging of mouse retinal vessels and blood flow that may play a pivotal role in providing a noninvasive method for detecting early microvascular changes in patients with diabetic retinopathy. PMID:24458155

  13. Noninvasive technique for measurement of heartbeat regularity in zebrafish (Danio rerio embryos

    Directory of Open Access Journals (Sweden)

    Cheng Shuk

    2009-02-01

    Full Text Available Abstract Background Zebrafish (Danio rerio, due to its optical accessibility and similarity to human, has emerged as model organism for cardiac research. Although various methods have been developed to assess cardiac functions in zebrafish embryos, there lacks a method to assess heartbeat regularity in blood vessels. Heartbeat regularity is an important parameter for cardiac function and is associated with cardiotoxicity in human being. Using stereomicroscope and digital video camera, we have developed a simple, noninvasive method to measure the heart rate and heartbeat regularity in peripheral blood vessels. Anesthetized embryos were mounted laterally in agarose on a slide and the caudal blood circulation of zebrafish embryo was video-recorded under stereomicroscope and the data was analyzed by custom-made software. The heart rate was determined by digital motion analysis and power spectral analysis through extraction of frequency characteristics of the cardiac rhythm. The heartbeat regularity, defined as the rhythmicity index, was determined by short-time Fourier Transform analysis. Results The heart rate measured by this noninvasive method in zebrafish embryos at 52 hour post-fertilization was similar to that determined by direct visual counting of ventricle beating (p > 0.05. In addition, the method was validated by a known cardiotoxic drug, terfenadine, which affects heartbeat regularity in humans and induces bradycardia and atrioventricular blockage in zebrafish. A significant decrease in heart rate was found by our method in treated embryos (p p Conclusion The data support and validate this rapid, simple, noninvasive method, which includes video image analysis and frequency analysis. This method is capable of measuring the heart rate and heartbeat regularity simultaneously via the analysis of caudal blood flow in zebrafish embryos. With the advantages of rapid sample preparation procedures, automatic image analysis and data analysis, this

  14. Noninvasive radiographic assessment of cardiovascular function in acute and chronic respiratory failure

    International Nuclear Information System (INIS)

    Berger, H.J.; Matthay, R.A.

    1981-01-01

    Noninvasive radiographic techniques have provided a means of studying the natural history and pathogenesis of cardiovascular performance in acute and chronic respiratory failure. Chest radiography, radionuclide angiocardiography and thallium-201 imaging, and M mode and cross-sectional echocardiography have been employed. Each of these techniques has specific uses, attributes and limitations. For example, measurement of descending pulmonary arterial diameters on the plain chest radiograph allows determination of the presence or absence of pulmonary arterial hypertension. Right and left ventricular performance can be evaluated at rest and during exercise using radionuclide angiocardiography. The biventricular response to exercise and to therapeutic interventions also can be assessed with this approach. Evaluation of the pulmonary valve echogram and echocardiographic right ventricular dimensions have been shown to reflect right ventricular hemodynamics and size. Each of these noninvasive techniques has been applied to the study of patients with respiratory failure and has provided important physiologic data

  15. Comparison of different models for non-invasive FFR estimation

    Science.gov (United States)

    Mirramezani, Mehran; Shadden, Shawn

    2017-11-01

    Coronary artery disease is a leading cause of death worldwide. Fractional flow reserve (FFR), derived from invasively measuring the pressure drop across a stenosis, is considered the gold standard to diagnose disease severity and need for treatment. Non-invasive estimation of FFR has gained recent attention for its potential to reduce patient risk and procedural cost versus invasive FFR measurement. Non-invasive FFR can be obtained by using image-based computational fluid dynamics to simulate blood flow and pressure in a patient-specific coronary model. However, 3D simulations require extensive effort for model construction and numerical computation, which limits their routine use. In this study we compare (ordered by increasing computational cost/complexity): reduced-order algebraic models of pressure drop across a stenosis; 1D, 2D (multiring) and 3D CFD models; as well as 3D FSI for the computation of FFR in idealized and patient-specific stenosis geometries. We demonstrate the ability of an appropriate reduced order algebraic model to closely predict FFR when compared to FFR from a full 3D simulation. This work was supported by the NIH, Grant No. R01-HL103419.

  16. Magnetic resonance imaging - first human images in Australia

    International Nuclear Information System (INIS)

    Baddeley, H.; Doddrell, D.M.; Brooks, W.M.; Field, J.; Irving, M.; Williams, J.E.

    1986-01-01

    The use of magnetic resonance imaging, in the demonstration of internal human anatomy and in the diagnosis of disease, has the major advantages that the technique is non-invasive, does not require the use of ionizing radiation and that it can demonstrate neurological and cardiovascular lesions that cannot be diagnosed easily by other imaging methods. The first magnetic resonance images of humans were obtained in Australia in October 1985 on the research instrument of the Queensland Medical Magnetic Resonance Research Centre, which is based at the Mater Hospital in Brisbane

  17. Non-invasive hemoglobin monitoring.

    Science.gov (United States)

    Joseph, Bellal; Haider, Ansab; Rhee, Peter

    2016-09-01

    Technology has transformed the practice of medicine and surgery in particular over the last several decades. This change in practice has allowed diagnostic and therapeutic tests to be performed less invasively. Hemoglobin monitoring remains one of the most commonly performed diagnostic tests in the United States. Recently, non-invasive hemoglobin monitoring technology has gained popularity. The aim of this article is to review the principles of how this technology works, pros and cons, and the implications of non-invasive hemoglobin technology particularly in trauma surgery. Copyright © 2015 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  18. Clinical application of noninvasive diagnosis of liver fibrosis

    Directory of Open Access Journals (Sweden)

    ZHU Chuanlong

    2015-03-01

    Full Text Available Hepatic fibrosis is the common outcome of chronic liver diseases of various causes. At present, liver biopsy is the “gold standard” for the diagnosis of liver fibrosis, but it has limitations and is invasive, which leads to the development of noninvasive assessment of liver fibrosis. The article mainly introduces the technology and application of noninvasive diagnosis of liver fibrosis from the aspects of clinical manifestation, serology, and radiology. It has pointed out the clinical value of these noninvasive diagnosis techniques, and it discusses the progress in clinical research and its limitations for noninvasive diagnosis of liver fibrosis.

  19. Non-invasive and non-destructive measurements of confluence in cultured adherent cell lines.

    Science.gov (United States)

    Busschots, Steven; O'Toole, Sharon; O'Leary, John J; Stordal, Britta

    2015-01-01

    Many protocols used for measuring the growth of adherent monolayer cells in vitro are invasive, destructive and do not allow for the continued, undisturbed growth of cells within flasks. Protocols often use indirect methods for measuring proliferation. Microscopy techniques can analyse cell proliferation in a non-invasive or non-destructive manner but often use expensive equipment and software algorithms. In this method images of cells within flasks are captured by photographing under a standard inverted phase contract light microscope using a digital camera with a camera lens adaptor. Images are analysed for confluence using ImageJ freeware resulting in a measure of confluence known as an Area Fraction (AF) output. An example of the AF method in use on OVCAR8 and UPN251 cell lines is included. •Measurements of confluence from growing adherent cell lines in cell culture flasks is obtained in a non-invasive, non-destructive, label-free manner.•The technique is quick, affordable and eliminates sample manipulation.•The technique provides an objective, consistent measure of when cells reach confluence and is highly correlated to manual counting with a haemocytometer. The average correlation co-efficient from a Spearman correlation (n = 3) was 0.99 ± 0.008 for OVCAR8 (p = 0.01) and 0.99 ± 0.01 for UPN251 (p = 0.01) cell lines.

  20. Two markers in predicting the cardiovascular events in patients with polycystic ovary syndrome: increased P-wave and QT dispersion.

    Science.gov (United States)

    Akdag, S; Cim, N; Yildizhan, R; Akyol, A; Ozturk, F; Babat, N

    2015-09-01

    Polycystic ovary syndrome (PCOS) is a prevalent disease with many potential long-term cardiovascular risks. P-wave dispersion (Pdis) and QT dispersion (QTdis) have been shown to be noninvasive electrocardiographic predictors for development of cardiac arrhythmias. In this study we aimed to search Pdis and QTdis parameters in patients with PCOS. The study included 82 patients with PCOS and 74 age- and sex-matched healthy controls. Baseline 12-lead electrocardiographic and transthoracic echocardiographic measurements were evaluated. P-wave maximum duration (Pmax), P-wave minimum duration (Pmin), Pdis, QT interval, heart rate-corrected QT dispersion and QTdis were calculated by two cardiologists. Patients wirh PCOS had significantly higher QT dispersion (49.5 ± 14.1 vs. 37.9 ± 12.6 ms, p PCOS patients.

  1. Advancing ecological understandings through technological transformations in noninvasive genetics.

    Science.gov (United States)

    Beja-Pereira, Albano; Oliveira, Rita; Alves, Paulo C; Schwartz, Michael K; Luikart, Gordon

    2009-09-01

    Noninvasive genetic approaches continue to improve studies in molecular ecology, conservation genetics and related disciplines such as forensics and epidemiology. Noninvasive sampling allows genetic studies without disturbing or even seeing the target individuals. Although noninvasive genetic sampling has been used for wildlife studies since the 1990s, technological advances continue to make noninvasive approaches among the most used and rapidly advancing areas in genetics. Here, we review recent advances in noninvasive genetics and how they allow us to address important research and management questions thanks to improved techniques for DNA extraction, preservation, amplification and data analysis. We show that many advances come from the fields of forensics, human health and domestic animal health science, and suggest that molecular ecologists explore literature from these fields. Finally, we discuss how the combination of advances in each step of a noninvasive genetics study, along with fruitful areas for future research, will continually increase the power and role of noninvasive genetics in molecular ecology and conservation genetics. © 2009 Blackwell Publishing Ltd.

  2. Face Masks for Noninvasive Ventilation: Fit, Excess Skin Hydration, and Pressure Ulcers.

    Science.gov (United States)

    Visscher, Marty O; White, Cynthia C; Jones, Jennifer M; Cahill, Thomas; Jones, Donna C; Pan, Brian S

    2015-11-01

    Pressure ulcers (stages III and IV) are serious safety events (ie, never events). Healthcare institutions are no longer reimbursed for costs to care for affected patients. Medical devices are the leading cause of pediatric pressure ulcers. Face masks for noninvasive ventilation were associated with a high percentage of pressure ulcers at our institution. A prospective cohort study investigated factors contributing to pressure ulcer development in 50 subjects using face masks for noninvasive ventilation. Color imaging, 3-dimensional surface imaging, and skin hydration measurements were used to identify early skin compromise and evaluate 3 interventions to reduce trauma: (1) a silicone foam dressing, (2) a water/polyethylene oxide hydrogel dressing, and (3) a flexible cloth mask. A novel mask fit technique was used to examine the impact of fit on the potential for skin compromise. Fifty subjects age 10.4 ± 9.1 y participated with color images for 22, hydration for 34, and mask fit analysis for 16. Of these, 69% had diagnoses associated with craniofacial anomalies. Stage I pressure ulcers were the most common injury. Skin hydration difference was 317 ± 29 for sites with erythema versus 75 ± 28 for sites without erythema (P skin erythema and pressure ulcers. This fit method is currently being utilized to select best-fit masks from available options, to identify the potential areas of increased tissue pressure, and to prevent skin injuries and their complications. Improvement of mask fit is an important priority for improving respiratory outcomes. Strategies to maintain normal skin hydration are important for protecting tissue integrity. Copyright © 2015 by Daedalus Enterprises.

  3. Imaging oxygenation of human tumours

    International Nuclear Information System (INIS)

    Padhani, Anwar R.; Krohn, Kenneth A.; Lewis, Jason S.; Alber, Markus

    2007-01-01

    Tumour hypoxia represents a significant challenge to the curability of human tumours leading to treatment resistance and enhanced tumour progression. Tumour hypoxia can be detected by non-invasive and invasive techniques but the inter-relationships between these remains largely undefined. 18 F-MISO and Cu-ATSM-PET, and BOLD-MRI are the lead contenders for human application based on their non-invasive nature, ease of use and robustness, measurement of hypoxia status, validity, ability to demonstrate heterogeneity and general availability, these techniques are the primary focus of this review. We discuss where developments are required for hypoxia imaging to become clinically useful and explore potential new uses for hypoxia imaging techniques including biological conformal radiotherapy. (orig.)

  4. Diagnostic imaging in medicine. 2nd ed

    Energy Technology Data Exchange (ETDEWEB)

    Reba, R C; Goodenough, D J; Davidson, H F

    1984-01-01

    This book describes to practitioners the evolutionary progression of new non-invasive diagnostic imaging techniques. The utility of the procedures is also described in a series of state-of-the-art lectures given by outstanding international clinical investigators from NATO countries. Subjects of the papers include the following: advances in source and detector technology, acoustical imaging, NMR and microwave imaging, positron and single photon emission tomography, digital radiography and image processing and display techniques. Fundamental papers describing the theory of non-invasive procedures are included along with papers describing clinical examinations. Examples of utility and studies of diseases of the abdomen and pelvis, heart and lung, and central nervous system are included. Cost-effective and cost-benefit assessment of the new high technology procedures, as well as the use of diagnostic imaging techniques in developing countries are also presented. An index of leading topics completes the volume.

  5. Non-invasive imaging of transplanted human neural stem cells and ECM scaffold remodeling in the stroke-damaged rat brain by 19F- and diffusion-MRI

    Science.gov (United States)

    Bible, Ellen; Dell’Acqua, Flavio; Solanky, Bhavana; Balducci, Anthony; Crapo, Peter; Badylak, Stephen F.; Ahrens, Eric T.; Modo, Michel

    2012-01-01

    Transplantation of human neural stem cells (hNSCs) is emerging as a viable treatment for stroke related brain injury. However, intraparenchymal grafts do not regenerate lost tissue, but rather integrate into the host parenchyma without significantly affecting the lesion cavity. Providing a structural support for the delivered cells appears important for cell based therapeutic approaches. The non-invasive monitoring of therapeutic methods would provide valuable information regarding therapeutic strategies but remains a challenge. Labeling transplanted cells with metal-based 1H-magnetic resonance imaging (MRI) contrast agents affects the visualization of the lesion cavity. Herein, we demonstrate that a 19F-MRI contrast agent can adequately monitor the distribution of transplanted cells, whilst allowing an evaluation of the lesion cavity and the formation of new tissue on 1H-MRI scans. Twenty percent of cells labeled with the 19F-agent were of host origin, potentially reflecting the re-uptake of label from dead transplanted cells. Both T2- and diffusion-weighted MRI scans indicated that transplantation of hNSCs suspended in a gel form of a xenogeneic extracellular matrix (ECM) bioscaffold resulted in uniformly distributed cells throughout the lesion cavity. However, diffusion MRI indicated that the injected materials did not yet establish diffusion barriers (i.e. cellular network, fiber tracts) normally found within striatal tissue. The ECM bioscaffold therefore provides an important support to hNSCs for the creation of de novo tissue and multi-nuclei MRI represents an adept method for the visualization of some aspects of this process. However, significant developments of both the transplantation paradigm, as well as regenerative imaging, are required to successfully create new tissue in the lesion cavity and to monitor this process non-invasively. PMID:22244696

  6. Non-invasive imaging of transplanted human neural stem cells and ECM scaffold remodeling in the stroke-damaged rat brain by (19)F- and diffusion-MRI.

    Science.gov (United States)

    Bible, Ellen; Dell'Acqua, Flavio; Solanky, Bhavana; Balducci, Anthony; Crapo, Peter M; Badylak, Stephen F; Ahrens, Eric T; Modo, Michel

    2012-04-01

    Transplantation of human neural stem cells (hNSCs) is emerging as a viable treatment for stroke related brain injury. However, intraparenchymal grafts do not regenerate lost tissue, but rather integrate into the host parenchyma without significantly affecting the lesion cavity. Providing a structural support for the delivered cells appears important for cell based therapeutic approaches. The non-invasive monitoring of therapeutic methods would provide valuable information regarding therapeutic strategies but remains a challenge. Labeling transplanted cells with metal-based (1)H-magnetic resonance imaging (MRI) contrast agents affects the visualization of the lesion cavity. Herein, we demonstrate that a (19)F-MRI contrast agent can adequately monitor the distribution of transplanted cells, whilst allowing an evaluation of the lesion cavity and the formation of new tissue on (1)H-MRI scans. Twenty percent of cells labeled with the (19)F agent were of host origin, potentially reflecting the re-uptake of label from dead transplanted cells. Both T(2)- and diffusion-weighted MRI scans indicated that transplantation of hNSCs suspended in a gel form of a xenogeneic extracellular matrix (ECM) bioscaffold resulted in uniformly distributed cells throughout the lesion cavity. However, diffusion MRI indicated that the injected materials did not yet establish diffusion barriers (i.e. cellular network, fiber tracts) normally found within striatal tissue. The ECM bioscaffold therefore provides an important support to hNSCs for the creation of de novo tissue and multi-nuclei MRI represents an adept method for the visualization of some aspects of this process. However, significant developments of both the transplantation paradigm, as well as regenerative imaging, are required to successfully create new tissue in the lesion cavity and to monitor this process non-invasively. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Improved Geologic Interpretation of Non-invasive Electrical Resistivity Imaging from In-situ Samples

    Science.gov (United States)

    Mucelli, A.; Aborn, L.; Jacob, R.; Malusis, M.; Evans, J.

    2016-12-01

    Non-invasive geophysical techniques are useful in characterizing the subsurface geology without disturbing the environment, however, the ability to interpret the subsurface is enhanced by invasive work. Since geologic materials have electrical resistivity values it allows for a geologic interpretation to be made based on variations of electrical resistivity measured by electrical resistivity imaging (ERI). This study focuses on the pre-characterization of the geologic subsurface from ERI collected adjacent to the Montandon Marsh, a wetland located near Lewisburg, PA within the West Branch of the Susquehanna River watershed. The previous invasive data, boreholes, indicate that the subsurface consists of limestone and shale bedrock overlain with sand and gravel deposits from glacial outwash and aeolian processes. The objective is to improve our understanding of the subsurface at this long-term hydrologic research site by using excavation results, specifically observed variations in geologic materials and electrical resistivity laboratory testing of subsurface samples. The pre-excavation ERI indicated that the shallow-most geologic material had a resistivity value of 100-500 ohm-m. In comparison, the laboratory testing indicated the shallow-most material had the same range of electrical resistivity values depending on saturation levels. The ERI also showed that there was an electrically conductive material, 7 to 70 ohm-m, that was interpreted to be clay and agreed with borehole data, however, the excavation revealed that at this depth range the geologic material varied from stratified clay to clay with cobbles to weathered residual clay. Excavation revealed that the subtle variations in the electrical conductive material corresponded well with the variations in the geologic material. We will use these results to reinterpret previously collected ERI data from the entire long-term research site.

  8. Deconstructing autofluorescence: non-invasive detection and monitoring of biochemistry in cells and tissues (Conference Presentation)

    Science.gov (United States)

    Goldys, Ewa M.; Gosnell, Martin E.; Anwer, Ayad G.; Cassano, Juan C.; Sue, Carolyn M.; Mahbub, Saabah B.; Pernichery, Sandeep M.; Inglis, David W.; Adhikary, Partho P.; Jazayeri, Jalal A.; Cahill, Michael A.; Saad, Sonia; Pollock, Carol; Sutton-Mcdowall, Melanie L.; Thompson, Jeremy G.

    2016-03-01

    Automated and unbiased methods of non-invasive cell monitoring able to deal with complex biological heterogeneity are fundamentally important for biology and medicine. Label-free cell imaging provides information about endogenous fluorescent metabolites, enzymes and cofactors in cells. However extracting high content information from imaging of native fluorescence has been hitherto impossible. Here, we quantitatively characterise cell populations in different tissue types, live or fixed, by using novel image processing and a simple multispectral upgrade of a wide-field fluorescence microscope. Multispectral intrinsic fluorescence imaging was applied to patient olfactory neurosphere-derived cells, cell model of a human metabolic disease MELAS (mitochondrial myopathy, encephalomyopathy, lactic acidosis, stroke-like syndrome). By using an endogenous source of contrast, subtle metabolic variations have been detected between living cells in their full morphological context which made it possible to distinguish healthy from diseased cells before and after therapy. Cellular maps of native fluorophores, flavins, bound and free NADH and retinoids unveiled subtle metabolic signatures and helped uncover significant cell subpopulations, in particular a subpopulation with compromised mitochondrial function. The versatility of our method is further illustrated by detecting genetic mutations in cancer, non-invasive monitoring of CD90 expression, label-free tracking of stem cell differentiation, identifying stem cell subpopulations with varying functional characteristics, tissue diagnostics in diabetes, and assessing the condition of preimplantation embryos. Our optimal discrimination approach enables statistical hypothesis testing and intuitive visualisations where previously undetectable differences become clearly apparent.

  9. Image-reconstruction methods in positron tomography

    CERN Document Server

    Townsend, David W; CERN. Geneva

    1993-01-01

    Physics and mathematics for medical imaging In the two decades since the introduction of the X-ray scanner into radiology, medical imaging techniques have become widely established as essential tools in the diagnosis of disease. As a consequence of recent technological and mathematical advances, the non-invasive, three-dimensional imaging of internal organs such as the brain and the heart is now possible, not only for anatomical investigations using X-rays but also for studies which explore the functional status of the body using positron-emitting radioisotopes and nuclear magnetic resonance. Mathematical methods which enable three-dimentional distributions to be reconstructed from projection data acquired by radiation detectors suitably positioned around the patient will be described in detail. The lectures will trace the development of medical imaging from simpleradiographs to the present-day non-invasive measurement of in vivo boichemistry. Powerful techniques to correlate anatomy and function that are cur...

  10. EPR oxygen imaging and hyperpolarized 13C MRI of pyruvate metabolism as noninvasive biomarkers of tumor treatment response to a glycolysis inhibitor 3-bromopyruvate.

    Science.gov (United States)

    Matsumoto, Shingo; Saito, Keita; Yasui, Hironobu; Morris, H Douglas; Munasinghe, Jeeva P; Lizak, Martin; Merkle, Hellmut; Ardenkjaer-Larsen, Jan Henrik; Choudhuri, Rajani; Devasahayam, Nallathamby; Subramanian, Sankaran; Koretsky, Alan P; Mitchell, James B; Krishna, Murali C

    2013-05-01

    The hypoxic nature of tumors results in treatment resistance and poor prognosis. To spare limited oxygen for more crucial pathways, hypoxic cancerous cells suppress mitochondrial oxidative phosphorylation and promote glycolysis for energy production. Thereby, inhibition of glycolysis has the potential to overcome treatment resistance of hypoxic tumors. Here, EPR imaging was used to evaluate oxygen dependent efficacy on hypoxia-sensitive drug. The small molecule 3-bromopyruvate blocks glycolysis pathway by inhibiting hypoxia inducible enzymes and enhanced cytotoxicity of 3-bromopyruvate under hypoxic conditions has been reported in vitro. However, the efficacy of 3-bromopyruvate was substantially attenuated in hypoxic tumor regions (pO23-bromopyruvate in SCCVII tumor. The discrepant results between in vitro and in vivo data were attributed to biphasic oxygen dependent expression of monocarboxylate transporter-1 in vivo. Expression of monocarboxylate transporter-1 was enhanced in moderately hypoxic (8-15 mmHg) tumor regions but down regulated in severely hypoxic (<5 mmHg) tumor regions. These results emphasize the importance of noninvasive imaging biomarkers to confirm the action of hypoxia-activated drugs. Copyright © 2012 Wiley Periodicals, Inc.

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  12. Imaging noradrenergic influence on amyloid pathology in mouse models of Alzheimer's disease

    International Nuclear Information System (INIS)

    Winkeler, A.; Waerzeggers, Y.; Klose, A.; Monfared, P.; Thomas, A.V.; Jacobs, A.H.; Schubert, M.; Heneka, M.T.

    2008-01-01

    Molecular imaging aims towards the non-invasive characterization of disease-specific molecular alterations in the living organism in vivo. In that, molecular imaging opens a new dimension in our understanding of disease pathogenesis, as it allows the non-invasive determination of the dynamics of changes on the molecular level. The imaging technology being employed includes magnetic resonance imaging (MRI) and nuclear imaging as well as optical-based imaging technologies. These imaging modalities are employed together or alone for disease phenotyping, development of imaging-guided therapeutic strategies and in basic and translational research. In this study, we review recent investigations employing positron emission tomography and MRI for phenotyping mouse models of Alzheimers' disease by imaging. We demonstrate that imaging has an important role in the characterization of mouse models of neurodegenerative diseases. (orig.)

  13. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  14. Electrocardiographic findings in patients with polycythemia vera.

    Science.gov (United States)

    Kayrak, Mehmet; Acar, Kadir; Gul, Enes Elvin; Abdulhalikov, Turyan; Bağlıcaklıoğlu, Murat; Sonmez, Osman; Kaya, Zeynettin; Arı, Hatem

    2012-01-01

    The 12-lead surface electrocardiogram (ECG) is a useful tool to predict both atrial and ventricular arrhythmias via P-wave and QT measurements and its derivatives. Polycythemia vera (PV) is a chronic myeloproliferative disorder associated with cardiovascular events. The aim of this study was to assess ECG findings of patients with PV. Sixty patients with PV (34 male, mean age 58±11 years) and 60 age and gender-matched healthy volunteers were enrolled into the study. From the 12-lead surface ECG, P-wave and both conventional QT measurements and transmyocardial repolarization parameters (T(peak)-T(end) interval (T(p)-T(e)) and derivatives) were evaluated digitally by two experienced cardiologists. In addition, a novel parameter, Pi was calculated digitally as the standard deviation of the P-wave duration across the 12 ECG leads. QT duration and corrected QT interval were significantly longer in the PV group compared to healthy controls (pe) was longer and the T(p)-T(e)/QT ratio was significantly higher in the PV group compared to the controls. P-wave analyses showed that all P-wave parameters including Pmax, Pmin, P dispersion, and Pi were significantly prolonged in PV patients compared to the controls. The increase of both T(p)-T(e )and P max in the PV group was independent of age, BMI, diabetes and hypertension, gender, systolic blood pressure, hemoglobin, hematocrit, left atrial dimension, left ventricular end-diastolic diameter and early deceleration time in a univariate analysis of co-variance model (F=11.097, p=0.001 and F=31.537, p=0.0001, respectively). The present study demonstrated that PV may be associated with electrocardiographic abnormalities of both atrium and ventricle.

  15. Triple vessel coronary artery disease presenting as a markedly positive stress electrocardiographic test and a negative SPECT-TL scintigram: a case of balanced Ischemia

    Directory of Open Access Journals (Sweden)

    Eyal Herzog

    2011-09-01

    Full Text Available The presence of false negative nuclear stress test in the settings of positive electrocardiographic changes is a very unusual phenomenon and is usually secondary to balanced ischemia of the myocardial segments evaluated by SPECT-TL. We present a case of an 81- year old post-menopausal female who presented to her primary care physician for evaluation of a 6-week dyspnea on exertion and was referred to our institution for exercise stress test with Thallium SPECT with the objective of ruling out coronary artery disease and identifying possible areas of myocardial ischemia. The resting electrocardiogram was unremarkable and stress test evaluation was made. The patient was admitted to the cardiac care unit and coronary artery bypass grafting was successfully performed. The presence of false negative nuclear stress test in the settings of positive electrocardiographic changes is a very unusual phenomenon and is usually secondary to balanced ischemia of the myocardial segments evaluated by SPECT-TL. Patients undergoing stress tests with these characteristics should undergo careful evaluation and a high level of suspicion should be adopted for further diagnostic assessment of coronary artery disease.

  16. Machine learning based analysis of cardiovascular images

    NARCIS (Netherlands)

    Wolterink, JM

    2017-01-01

    Cardiovascular diseases (CVDs), including coronary artery disease (CAD) and congenital heart disease (CHD) are the global leading cause of death. Computed tomography (CT) and magnetic resonance imaging (MRI) allow non-invasive imaging of cardiovascular structures. This thesis presents machine

  17. Targeted molecular imaging

    International Nuclear Information System (INIS)

    Kim, E. Edmund

    2003-01-01

    Molecular imaging aims to visualize the cellular and molecular processes occurring in living tissues, and for the imaging of specific molecules in vivo, the development of reporter probes and dedicated imaging equipment is most important. Reporter genes can be used to monitor the delivery and magnitude of therapeutic gene transfer, and the time variation involved. Imaging technologies such as micro-PET, SPECT, MRI and CT, as well as optical imaging systems, are able to non-invasively detect, measure, and report the simultaneous expression of multiple meaningful genes. It is believed that recent advances in reporter probes, imaging technologies and gene transfer strategies will enhance the effectiveness of gene therapy trials

  18. Functional and molecular imaging with MRI: potential applications in paediatric radiology

    International Nuclear Information System (INIS)

    Arthurs, Owen J.; Gallagher, Ferdia A.

    2011-01-01

    MRI is a very versatile tool for noninvasive imaging and it is particularly attractive as an imaging technique in paediatric patients given the absence of ionizing radiation. Recent advances in the field of MRI have enabled tissue function to be probed noninvasively, and increasingly MRI is being used to assess cellular and molecular processes. For example, dynamic contrast-enhanced MRI has been used to assess tissue vascularity, diffusion-weighted imaging can quantify molecular movements of water in tissue compartments and MR spectroscopy provides a quantitative assessment of metabolite levels. A number of targeted contrast agents have been developed that bind specifically to receptors on the vascular endothelium or cell surface and there are several MR methods for labelling cells and tracking cellular movements. Hyperpolarization techniques have the capability of massively increasing the sensitivity of MRI and these have been used to image tissue pH, successful response to drug treatment as well as imaging the microstructure of the lungs. Although there are many challenges to be overcome before these techniques can be translated into routine paediatric imaging, they could potentially be used to aid diagnosis, predict disease outcome, target biopsies and determine treatment response noninvasively. (orig.)

  19. Image Analysis for X-ray Imaging of Food

    DEFF Research Database (Denmark)

    Einarsdottir, Hildur

    for quality and safety evaluation of food products. In this effort the fields of statistics, image analysis and statistical learning are combined, to provide analytical tools for determining the aforementioned food traits. The work demonstrated includes a quantitative analysis of heat induced changes......X-ray imaging systems are increasingly used for quality and safety evaluation both within food science and production. They offer non-invasive and nondestructive penetration capabilities to image the inside of food. This thesis presents applications of a novel grating-based X-ray imaging technique...... and defect detection in food. Compared to the complex three dimensional analysis of microstructure, here two dimensional images are considered, making the method applicable for an industrial setting. The advantages obtained by grating-based imaging are compared to conventional X-ray imaging, for both foreign...

  20. Dynamic studies of cardiac valvular disease using a new fast multiphase MR imaging technique

    International Nuclear Information System (INIS)

    Pettigrew, R.; Churchwell, A.; Parks, W.J.; Dannels, W.; Smith, H. III; Baron, M.G.

    1986-01-01

    To determine the potential utility of fast multiphase (FM) imaging for the assessment of cardiac valvular disease, ten healthy volunteers and 18 patients were studied. The FM technique employed gradient echoes with TE -- 15 msec and small exitation angles with TR -- 50 msec. Cine display of the electrocardiographically gated FM images allowed clear visualization of regurgitant blood flow in each of 15 patients with tricuspid or mitral insufficiency. Magnetic field distortions in two patients with Bjork-Shiley aortic prostheses and regurgitation prevented definitive visualization of the flow patterns. An equivocal flow pattern was seen in one case of mitral stenosis. Thus, FM imaging may have significant utility as an adjunctive procedure for the assessment of atrioventricular valve insufficiently, without requiring a contrast agent. Difficulties may exist with some prosthetic valves

  1. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the canine heart.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2012-01-01

    Single-beat imaging of myocardial activation promises to aid in both cardiovascular research and clinical medicine. In the present study we validate a three-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of simultaneous 3D intracardiac mapping to assess its capability to localize endocardial and epicardial initiation sites and image global activation sequences during pacing and ventricular tachycardia (VT) in the canine heart. Body surface potentials were measured simultaneously with bipolar electrical recordings in a closed-chest condition in healthy canines. Computed tomography images were obtained after the mapping study to construct realistic geometry models. Data analysis was performed on paced rhythms and VTs induced by norepinephrine (NE). The noninvasively reconstructed activation sequence was in good agreement with the simultaneous measurements from 3D cardiac mapping with a correlation coefficient of 0.74 ± 0.06, a relative error of 0.29 ± 0.05, and a root mean square error of 9 ± 3 ms averaged over 460 paced beats and 96 ectopic beats including premature ventricular complexes, couplets, and nonsustained monomorphic VTs and polymorphic VTs. Endocardial and epicardial origins of paced beats were successfully predicted in 72% and 86% of cases, respectively, during left ventricular pacing. The NE-induced ectopic beats initiated in the subendocardium by a focal mechanism. Sites of initial activation were estimated to be ∼7 mm from the measured initiation sites for both the paced beats and ectopic beats. For the polymorphic VTs, beat-to-beat dynamic shifts of initiation site and activation pattern were characterized by the reconstruction. The present results suggest that 3DCEI can noninvasively image the 3D activation sequence and localize the origin of activation of paced beats and NE-induced VTs in the canine heart with good accuracy. This 3DCEI technique offers the potential to aid interventional therapeutic procedures for

  2. Non-invasive cardiac imaging. Spectrum, methodology, indication and interpretation

    International Nuclear Information System (INIS)

    Schaefers, Michael; Flachskampf, Frank; Sechtem, Udo; Achenbach, Stephan; Krause, Bernd J.; Schwaiger, Markus; Breithardt, Guenter

    2008-01-01

    The book contains 13 contributions concerning the following chapters: (1)methodology: echo cardiography; NMR imaging; nuclear medicine; computer tomography, (2) clinical protocols: contraction; cardiac valve function; perfusion and perfusion reserve; vitality; corona imaging; transmitters, receptors, enzymes; (3) clinic: coronary heart diseases; non-ischemic heart diseases. The appendix contains two contributions on future developments and certification/standardization

  3. Non-invasive glucagon-like peptide-1 receptor imaging in pancreas with {sup 18}F-Al labeled Cys{sup 39}-exendin-4

    Energy Technology Data Exchange (ETDEWEB)

    Mi, Baoming [Department of Nuclear Medicine, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, 215006 (China); Department of Nuclear Medicine, Affiliated Hospital of Jiangnan University (Wuxi 4th People' s Hospital), Wuxi, Jiangsu, 214062 (China); Xu, Yuping [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi, Jiangsu, 214063 (China); Nanjing Medical University, Nanjing, Jiangsu, 210029 (China); Pan, Donghui; Wang, Lizhen; Yang, Runlin [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi, Jiangsu, 214063 (China); Yu, Chunjing; Wan, Weixing [Department of Nuclear Medicine, Affiliated Hospital of Jiangnan University (Wuxi 4th People' s Hospital), Wuxi, Jiangsu, 214062 (China); Wu, Yiwei, E-mail: wuyiwei3988@gmail.com [Department of Nuclear Medicine, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, 215006 (China); Yang, Min, E-mail: ymzfk@yahoo.com.hk [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi, Jiangsu, 214063 (China); Nanjing Medical University, Nanjing, Jiangsu, 210029 (China)

    2016-02-26

    Purpose: Glucagon-like peptide-1 receptor (GLP-1R) is abundantly expressed on beta cells and may be an ideal target for the pancreas imaging. Monitoring the GLP-1R of pancreas could be benefit for understanding the pathophysiology of diabetes. In the present study, {sup 18}F-Al labeled exendin-4 analog, {sup 18}F-Al-NOTA-MAL-Cys{sup 39}-exendin-4, was evaluated for PET imaging GLP-1R in the pancreas. Methods: The targeting of {sup 18}F-Al labeled exendin-4 analog was examined in healthy and streptozotocin induced diabetic rats. Rats were injected with {sup 18}F-Al-NOTA-MAL-Cys{sup 39}-exendin-4 and microPET imaging was performed at 1 h postinjection, followed by ex vivo biodistribution. GLP-1R expression in pancreas was determined through post mortern examinations. Results: The pancreas of healthy rats was readily visualized after administration of {sup 18}F-Al-NOTA-MAL-Cys{sup 39}-exendin-4, whereas the pancreas of diabetic rats, as well as those from rats co-injected with excess of unlabeled peptides, was barely visible by microPET. At 60 min postinjection, the pancreatic uptakes were 1.02 ± 0.15%ID/g and 0.23 ± 0.05%ID/g in healthy and diabetic rats respectively. Under block, the pancreatic uptakes of non-diabetic rats reduced to 0.21 ± 0.07%ID/g at the same time point. Biodistribution data and IHC staining confirmed the findings of the microPET imaging. Conclusion: The favorable preclinical data indicated that {sup 18}F-Al-NOTA-MAL-Cys{sup 39}-exendin-4may be suitable for non-invasive monitoring functional pancreatic beta cells.

  4. NON-INVASIVE INVERSE PROBLEM IN CIVIL ENGINEERING

    Directory of Open Access Journals (Sweden)

    Jan Havelka

    2017-11-01

    Full Text Available In this contribution we focus on recovery of spatial distribution of material parameters utilizing only non-invasive boundary measurements. Such methods has gained its importance as imaging techniques in medicine, geophysics or archaeology. We apply similar principles for non-stationary heat transfer in civil engineering. In oppose to standard technique which rely on external loading devices, we assume the natural fluctuation of temperature throughout day and night can provide sufficient information to recover the underlying material parameters. The inverse problem was solved by a modified regularised Gauss-Newton iterative scheme and the underlying forward problem is solved with a finite element space-time discretisation. We show a successful reconstruction of material parameters on a synthetic example with real measurements. The virtual experiment also reveals the insensitivity to practical precision of sensor measurements.

  5. Advancing ecological understandings through technological transformations in noninvasive genetics

    Science.gov (United States)

    Albano Beja-Pereira; Rita Oliveira; Paulo C. Alves; Michael K. Schwartz; Gordon Luikart

    2009-01-01

    Noninvasive genetic approaches continue to improve studies in molecular ecology, conservation genetics and related disciplines such as forensics and epidemiology. Noninvasive sampling allows genetic studies without disturbing or even seeing the target individuals. Although noninvasive genetic sampling has been used for wildlife studies since the 1990s, technological...

  6. Epilepsy-induced electrocardiographic alterations following cardiac ischemia and reperfusion in rats

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, J.G.P. [Departamento de Farmacologia, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Universidade Iguaçu, Campos V, Itaperuna, RJ (Brazil); Faculdade de Minas, Muriaé, MG (Brazil); Vasques, E.R. [Departamento de Gastroenterologia, LIM 37, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil); Arida, R.M. [Departamento de Fisiologia, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Cavalheiro, E.A. [Departamento de Neurologia e Neurocirurgia, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Cabral, F.R.; Torres, L.B. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Menezes-Rodrigues, F.S.; Jurkiewicz, A.; Caricati-Neto, A. [Departamento de Farmacologia, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Godoy, C.M.G. [Departamento de Ciência e Tecnologia, Universidade Federal de São Paulo, São José dos Campos, SP (Brazil); Gomes da Silva, S. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Núcleo de Pesquisas Tecnológicas, Programa Integrado em Engenharia Biomédica, Universidade de Mogi das Cruzes, Mogi das Cruzes, SP (Brazil)

    2015-01-13

    The present study evaluated electrocardiographic alterations in rats with epilepsy submitted to an acute myocardial infarction (AMI) model induced by cardiac ischemia and reperfusion. Rats were randomly divided into two groups: control (n=12) and epilepsy (n=14). It was found that rats with epilepsy presented a significant reduction in atrioventricular block incidence following the ischemia and reperfusion procedure. In addition, significant alterations were observed in electrocardiogram intervals during the stabilization, ischemia, and reperfusion periods of rats with epilepsy compared to control rats. It was noted that rats with epilepsy presented a significant increase in the QRS interval during the stabilization period in relation to control rats (P<0.01). During the ischemia period, there was an increase in the QRS interval (P<0.05) and a reduction in the P wave and QT intervals (P<0.05 for both) in rats with epilepsy compared to control rats. During the reperfusion period, a significant reduction in the QT interval (P<0.01) was verified in the epilepsy group in relation to the control group. Our results indicate that rats submitted to an epilepsy model induced by pilocarpine presented electrical conductivity alterations of cardiac tissue, mainly during an AMI episode.

  7. Epilepsy-induced electrocardiographic alterations following cardiac ischemia and reperfusion in rats

    International Nuclear Information System (INIS)

    Tavares, J.G.P.; Vasques, E.R.; Arida, R.M.; Cavalheiro, E.A.; Cabral, F.R.; Torres, L.B.; Menezes-Rodrigues, F.S.; Jurkiewicz, A.; Caricati-Neto, A.; Godoy, C.M.G.; Gomes da Silva, S.

    2015-01-01

    The present study evaluated electrocardiographic alterations in rats with epilepsy submitted to an acute myocardial infarction (AMI) model induced by cardiac ischemia and reperfusion. Rats were randomly divided into two groups: control (n=12) and epilepsy (n=14). It was found that rats with epilepsy presented a significant reduction in atrioventricular block incidence following the ischemia and reperfusion procedure. In addition, significant alterations were observed in electrocardiogram intervals during the stabilization, ischemia, and reperfusion periods of rats with epilepsy compared to control rats. It was noted that rats with epilepsy presented a significant increase in the QRS interval during the stabilization period in relation to control rats (P<0.01). During the ischemia period, there was an increase in the QRS interval (P<0.05) and a reduction in the P wave and QT intervals (P<0.05 for both) in rats with epilepsy compared to control rats. During the reperfusion period, a significant reduction in the QT interval (P<0.01) was verified in the epilepsy group in relation to the control group. Our results indicate that rats submitted to an epilepsy model induced by pilocarpine presented electrical conductivity alterations of cardiac tissue, mainly during an AMI episode

  8. Noninvasive enhanced mid-IR imaging of breast cancer development in vivo

    Science.gov (United States)

    Case, Jason R.; Young, Madison A.; Dréau, D.; Trammell, Susan R.

    2015-11-01

    Lumpectomy coupled with radiation therapy and/or chemotherapy is commonly used to treat breast cancer patients. We are developing an enhanced thermal IR imaging technique that has the potential to provide real-time imaging to guide tissue excision during a lumpectomy by delineating tumor margins. This enhanced thermal imaging method is a combination of IR imaging (8 to 10 μm) and selective heating of blood (˜0.5°C) relative to surrounding water-rich tissue using LED sources at low powers. Postacquisition processing of these images highlights temporal changes in temperature and the presence of vascular structures. In this study, fluorescent, standard thermal, and enhanced thermal imaging modalities, as well as physical caliper measurements, were used to monitor breast cancer tumor volumes over a 30-day study period in 19 mice implanted with 4T1-RFP tumor cells. Tumor volumes calculated from fluorescent imaging follow an exponential growth curve for the first 22 days of the study. Cell necrosis affected the tumor volume estimates based on the fluorescent images after day 22. The tumor volumes estimated from enhanced thermal imaging, standard thermal imaging, and caliper measurements all show exponential growth over the entire study period. A strong correlation was found between tumor volumes estimated using fluorescent imaging, standard IR imaging, and caliper measurements with enhanced thermal imaging, indicating that enhanced thermal imaging monitors tumor growth. Further, the enhanced IR images reveal a corona of bright emission along the edges of the tumor masses associated with the tumor margin. In the future, this IR technique might be used to estimate tumor margins in real time during surgical procedures.

  9. Myocardial perfusion imaging for detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Beller, G.A.

    1988-01-01

    Despite the widespread use of the exercise stress test in diagnosing asymptomatic myocardial ischemia, exercise radionuclide imaging remains useful for detecting silent ischemia in numerous patient populations, including those who are totally asymptomatic, those who have chronic stable angina, those who have recovered from an episode of unstable angina or an uncomplicated myocardial infarction, and those who have undergone angioplasty or received thrombolytic therapy. Studies show that thallium scintigraphy is more sensitive than exercise electrocardiography in detecting ischemia, i.e., in part, because perfusion defects occur more frequently than ST depression and before angina in the ischemic cascade. Thallium-201 scintigraphy can be performed to differentiate a true- from a false-positive exercise electrocardiographic test in patients with exercise-induced ST depression and no angina. The development of technetium-labeled isonitriles may improve the accuracy of myocardial perfusion imaging. 11 references

  10. The stability of myocardial area at risk estimated electrocardiographically in patients with ST elevation myocardial infarction

    DEFF Research Database (Denmark)

    Carlsen, Esben A; Hassell, Mariëlla E C J; van Hellemond, Irene E G

    2014-01-01

    In patients with ST-elevation myocardial infarction (STEMI) the amount of myocardial area at risk (MaR) indicates the maximal potential loss of myocardium if the coronary artery remains occluded. During the time course of infarct evolution ischemic MaR is replaced by necrosis, which results...... in a decrease in ST segment elevation and QRS complex distortion. Recently it has been shown that combining the electrocardiographic (ECG) Aldrich ST and Selvester QRS scores result in a more accurate estimate of MaR than using either method alone. Therefore, we hypothesized that the combined Aldrich...... reperfusion (ECG2). The combined Aldrich and Selvester score was considered stable if the difference between ECG1 and ECG2 was ST elevation in 4...

  11. Electrocardiographic changes in the most frequent endocrine disorders associated with cardiovascular diseases. Review of the literature.

    Science.gov (United States)

    Costache, Irina Iuliana; Ungureanu, Maria Christina; Iliescu, D; Petriş, A; Botnariu, Gina

    2015-01-01

    Car- diovascular abnormalities associated with endocrine diseases are often frequent and due to complex relationships between endocrine glands (with internal secretion) and cardiovascular system (heart and vessels). Certain hormones secreted by the endocrine glands (particularly the thyroid and pituitary gland) excesses or deficiencies, are involved in morphogenesis, growth processes and activity regulation of cardiovascular system, most often in connection with the autonomic nervous system. There are also a lot of electrocardiographic changes caused by hormonal disorders that requires differential diagnosis and represents the source of erroneous diagnosis. Endocrine pathology occurred later than a heart disease, may worse heart function. Ignoring the cardiovascular events that may occur in the evolution of endo- crine diseases, may induce increased mortality due to cardiovascular complications.

  12. Atrial and Ventricular Electrocardiographic Dromotropic Disturbances in Down Syndrome Patients with Structurally Normal Heart: A Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Yazdan Ghandi

    2018-03-01

    Full Text Available Background: We designed a cross-sectional study to determine electrocardiographic disorders in Down syndrome patients with congenitally normal hearts in a bid to predict fatal cardiac arrhythmia in the future. Materials and Methods: We investigated 60 children with DS without congenital abnormal hearts. Sixty healthy juveniles were also included in the study as a control group. Physical examination, electrocardiography, and echocardiography were performed in all subjects. Corrected QT interval (QTc was measured according to Bazett’s formula. Results: Patients with DS consisted of 32 males (53.33%, and 28 females (46.66%, aged 6–13 (9.21 ± 6.24 years old. Healthy subjects comprised 31 males (51.66%, and 29 females (48.33% with a mean age of 9.15 ± 5.01. The two groups were significantly different in terms of heart rate (P=0.006, maximum P-wave duration (P=0.001, and P-wave dispersion (PWd, P=0.0001. There was no statistically significant difference regarding minimum P-wave duration (P=0.176. The patients with DS had a greater maximum QTc interval, QT dispersion, and corrected QT interval dispersion (QTc-d than the healthy control subjects (P=0.001. However, there was no difference in maximum QT interval and minimum QTc interval between the two groups (P=0.67 and P=0.553, respectively. A positive correlation was found between age, heart rate, and all electrocardiographic variables. Conclusion: All DS patients, even in the absence of concomitant congenital heart disease should be followed up carefully by electrocardiography, looking for increased PWd and QTc-d to detect predisposed cases to arrhythmia.

  13. Precision analysis of a multi-slice ultrasound sensor for non-invasive 3D kinematic analysis of knee joints.

    Science.gov (United States)

    Masum, Md Abdullah; Lambert, Andrew J; Pickering, Mark R; Scarvell, J M; Smith, P N

    2012-01-01

    Currently the standard clinical practice for measuring the motion of bones in a knee joint with sufficient precision involves implanting tantalum beads into the bones to act as fiducial markers prior to imaging using X-ray equipment. This procedure is invasive in nature and exposure to ionizing radiation imposes a cancer risk and the patient's movements are confined to a narrow field of view. In this paper, an ultrasound based system for non-invasive kinematic evaluation of knee joints is proposed. The results of an initial analysis show that this system can provide the precision required for non-invasive motion analysis while the patient performs normal physical activities.

  14. Photoacoustic imaging and spectroscopy

    CERN Document Server

    Wang, Lihong

    2009-01-01

    Photoacoustics promises to revolutionize medical imaging and may well make as dramatic a contribution to modern medicine as the discovery of the x-ray itself once did. Combining electromagnetic and ultrasonic waves synergistically, photoacoustics can provide deep speckle-free imaging with high electromagnetic contrast at high ultrasonic resolution and without any health risk. While photoacoustic imaging is probably the fastest growing biomedical imaging technology, this book is the first comprehensive volume in this emerging field covering both the physics and the remarkable noninvasive applic

  15. The potential of electrocardiographic markers to tune cardiac device therapy

    NARCIS (Netherlands)

    Wijers, S.C.

    2017-01-01

    In this thesis an effort was made to translate basic research into clinical practice to improve cardiac device therapy. We showed the electrocardiogram (ECG) is everything but obsolete or outdated and is of great value as a simple non-invasive tool in identifying individuals that can benefit from

  16. Noninvasive, three-dimensional full-field body sensor for surface deformation monitoring of human body in vivo.

    Science.gov (United States)

    Chen, Zhenning; Shao, Xinxing; He, Xiaoyuan; Wu, Jialin; Xu, Xiangyang; Zhang, Jinlin

    2017-09-01

    Noninvasive, three-dimensional (3-D), full-field surface deformation measurements of the human body are important for biomedical investigations. We proposed a 3-D noninvasive, full-field body sensor based on stereo digital image correlation (stereo-DIC) for surface deformation monitoring of the human body in vivo. First, by applying an improved water-transfer printing (WTP) technique to transfer optimized speckle patterns onto the skin, the body sensor was conveniently and harmlessly fabricated directly onto the human body. Then, stereo-DIC was used to achieve 3-D noncontact and noninvasive surface deformation measurements. The accuracy and efficiency of the proposed body sensor were verified and discussed by considering different complexions. Moreover, the fabrication of speckle patterns on human skin, which has always been considered a challenging problem, was shown to be feasible, effective, and harmless as a result of the improved WTP technique. An application of the proposed stereo-DIC-based body sensor was demonstrated by measuring the pulse wave velocity of human carotid artery. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  17. Noninvasive vaccination against infectious diseases.

    Science.gov (United States)

    Zheng, Zhichao; Diaz-Arévalo, Diana; Guan, Hongbing; Zeng, Mingtao

    2018-04-06

    The development of a successful vaccine, which should elicit a combination of humoral and cellular responses to control or prevent infections, is the first step in protecting against infectious diseases. A vaccine may protect against bacterial, fungal, parasitic, or viral infections in animal models, but to be effective in humans there are some issues that should be considered, such as the adjuvant, the route of vaccination, and the antigen-carrier system. While almost all licensed vaccines are injected such that inoculation is by far the most commonly used method, injection has several potential disadvantages, including pain, cross contamination, needlestick injury, under- or overdosing, and increased cost. It is also problematic for patients from rural areas of developing countries, who must travel to a hospital for vaccine administration. Noninvasive immunizations, including oral, intranasal, and transcutaneous administration of vaccines, can reduce or eliminate pain, reduce the cost of vaccinations, and increase their safety. Several preclinical and clinical studies as well as experience with licensed vaccines have demonstrated that noninvasive vaccine immunization activates cellular and humoral immunity, which protect against pathogen infections. Here we review the development of noninvasive immunization with vaccines based on live attenuated virus, recombinant adenovirus, inactivated virus, viral subunits, virus-like particles, DNA, RNA, and antigen expression in rice in preclinical and clinical studies. We predict that noninvasive vaccine administration will be more widely applied in the clinic in the near future.

  18. Electrocardiographically gated snapshot MR angiography

    International Nuclear Information System (INIS)

    Brown, D.G.; Holsinger, A.E.; Riederer, S.J.

    1990-01-01

    The purpose of this paper is to evaluate the effectiveness of applying ultrashort (∼12 msec) TR times and measuring the central phase encodings first in improving the accuracy of vascular depiction in MR angiography. The imaging method combines ultrashort TR imaging techniques with time-of-flight MR angiography. The central phase-encoding views are acquired first, and an inversion-recovery contrast preparation pulse is applied prior to image acquisition to null signal from static tissues. In initial studies, the method was tested on phantoms and volunteers. The contrast-preparation phase effectively nulls static spins at the start of image acquisition. During the TL period fresh blood flows into the imaging section; even slowly moving blood is fully replaced

  19. NMR imaging of the musculoskeletal system

    International Nuclear Information System (INIS)

    Naegele, M.; Lienemann, A.; Hahn, D.

    1988-01-01

    NMR imaging now allows in vivo imaging of soft tissue hitherto undetectable by non-invasive means. This opens up excellent perspectives with regard to the diagnosis and therapy of various diseases in the field of traumatology and oncology, of which examples are discussed in this paper. (orig.) [de

  20. Noninvasive detection of coronary artery bypass graft patency by intravenous electron beam computed tomographic angiography.

    Science.gov (United States)

    Yamakami, Shoji; Toyama, Junji; Okamoto, Mitsuhiro; Matsushita, Toyoaki; Murakami, Yoshimasa; Ogata, Masaki; Ito, Shigenori; Fukutomi, Tatsuya; Okayama, Naotsuka; Itoh, Makoto

    2003-11-01

    This study evaluates the usefullness of intravenous electron beam computed tomographic angiography (EBA) for the detection of coronary artery bypass graft patency in 43 patients (33 men and 10 women, mean age, 65 years) who had coronary artery bypass graft surgery. EBA was performed a few days before selective bypass graft angiography (SGA). Forty axial cross-sections of angiographic images of the heart were acquired consecutively by an electrocardiographic trigger signal at 40% of the RR interval, which corresponds to the end-systolic phase. EBA data were reconstructed as a three-dimensional shaded surface display of the heart and bypass grafts. Detectability of the patency of bypass gratis was evaluated, taking selective angiographic images of the bypass grafts as a gold standard. One hundred and nine grafts (96%) out of 114 grafts were subjected to evaluation: 37 grafts were left internal mammary artery grafts (LIMA), 7 were right internal mammary artery grafts (RIMA), 6 were gastroepiploic artery grafts (GEA), 7 were free gastroepiploic artery grafts with venous drainage (free-GEA), 7 were radial artery grafts (RAG), and 45 were saphenous vein gratis (SVG). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBA were 98%, 100%, 100%, 91%, and 98%, respectively. EBA sampled at the end-systolic period was determined to be useful for the detection of coronary artery bypass graft patency and occlusion.

  1. Noninvasive Positive Pressure Ventilatory Support Begins During Sleep.

    Science.gov (United States)

    Bach, John R

    2017-12-01

    The goal of sleep doctors has been to titrate away apneas and hypopneas using noninvasive ventilation, a term that has become synonymous with continuous positive airway pressure and bilevel positive airway pressure at the lowest effective bilevel settings. It is now time to appreciate noninvasive ventilatory support as an alternative to invasive mechanical ventilation. This article discusses mechanisms of action, two paradigms, and ancillary techniques for noninvasive ventilatory support. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Imaging of basal cell carcinoma by high-definition optical coherence tomography

    DEFF Research Database (Denmark)

    Boone, M A L M; Norrenberg, S; Jemec, G B E

    2012-01-01

    With the continued development of noninvasive therapies for basal cell carcinoma (BCC) such as photodynamic therapy and immune therapies, noninvasive diagnosis and monitoring become increasingly relevant. High-definition optical coherence tomography (HD-OCT) is a high-resolution imaging tool, wit......, with micrometre resolution in both transversal and axial directions, enabling visualization of individual cells up to a depth of around 570 μm, and filling the imaging gap between conventional optical coherence tomography (OCT) and reflectance confocal microscopy (RCM)....

  3. PET-based molecular imaging in neuroscience

    International Nuclear Information System (INIS)

    Jacobs, A.H.; Heiss, W.D.; Li, H.; Knoess, C.; Schaller, B.; Kracht, L.; Monfared, P.; Vollmar, S.; Bauer, B.; Wagner, R.; Graf, R.; Wienhard, K.; Winkeler, A.; Rueger, A.; Klein, M.; Hilker, R.; Galldiks, N.; Herholz, K.; Sobesky, J.

    2003-01-01

    Positron emission tomography (PET) allows non-invasive assessment of physiological, metabolic and molecular processes in humans and animals in vivo. Advances in detector technology have led to a considerable improvement in the spatial resolution of PET (1-2 mm), enabling for the first time investigations in small experimental animals such as mice. With the developments in radiochemistry and tracer technology, a variety of endogenously expressed and exogenously introduced genes can be analysed by PET. This opens up the exciting and rapidly evolving field of molecular imaging, aiming at the non-invasive localisation of a biological process of interest in normal and diseased cells in animal models and humans in vivo. The main and most intriguing advantage of molecular imaging is the kinetic analysis of a given molecular event in the same experimental subject over time. This will allow non-invasive characterisation and ''phenotyping'' of animal models of human disease at various disease stages, under certain pathophysiological stimuli and after therapeutic intervention. The potential broad applications of imaging molecular events in vivo lie in the study of cell biology, biochemistry, gene/protein function and regulation, signal transduction, transcriptional regulation and characterisation of transgenic animals. Most importantly, molecular imaging will have great implications for the identification of potential molecular therapeutic targets, in the development of new treatment strategies, and in their successful implementation into clinical application. Here, the potential impact of molecular imaging by PET in applications in neuroscience research with a special focus on neurodegeneration and neuro-oncology is reviewed. (orig.)

  4. A new non-invasive and relocatable immobilization frame for fractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Theodorou, K.; Kappas, C.; Tsokas, C.

    1998-01-01

    Purpose: A newly developed non-invasive immobilization frame for stereotactic radiotherapy is presented, which is intended to be used for both imaging (computed tomography (CT) and angiography) and radiotherapeutic procedures. Materials and methods: The frame is made of duraluminium so as to be stable and light and it has an elliptical shape. The immobilization is achieved using three stable locations on the patient's head, i.e. the upper dentition, the nose and the back of the neck. The fixation on the three locations ensures complete immobilization in all directions. Results: The immobilization frame can be fitted as many times as is needed to most heads. In order to assess the accuracy of relocation, repeated fittings on two volunteers and on 22 patients undergoing stereotactic treatment were performed (more than 200 mountings in total), which showed maximum anterior-posterior, inferior-superior and lateral reproducibility in positioning of less than 1 mm in all cases. Conclusions and discussion: The in-house-constructed stereotactic frame is simple to use, easily made, non-invasive, relocatable and well tolerated by the patients, providing the possibility of multiple fractions. The major advantage of using such a non-invasive stereotactic frame is the flexibility in timing the different diagnostic procedures (CT and angiography) as well as providing the possibility to extend the use to large brain lesions (treatment without an additional collimator) where a high precision is also required. It also offers significant labour and cost saving over the invasive frames and the majority of the non-invasive frames. To date, 22 patients with ages varying between 12 and 70 years have been treated using this method. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  5. Clinical advances in cardiovascular magnetic resonace imaging and angiography

    NARCIS (Netherlands)

    Bosch, van den H.C.M.

    2018-01-01

    Cardiovascular magnetic resonance imaging is an important noninvasive imaging modality for the diagnosis, clinical work‐up and treatment planning in patients suspected for a wide range of cardiovascular pathology. CMR imaging is accurate and reliable, and provides invaluable information to evaluate

  6. An advanced design of non-radioactive image capturing and management system for applications in non-invasive skin disorder diagnosis

    Science.gov (United States)

    Liu, Carol Y. B.; Luk, David C. K.; Zhou, Kany S. Y.; So, Bryan M. K.; Louie, Derek C. H.

    2015-03-01

    Due to the increasing incidences of malignant melanoma, there is a rising demand for assistive technologies for its early diagnosis and improving the survival rate. The commonly used visual screening method is with limited accuracy as the early phase of melanoma shares many clinical features with an atypical nevus, while conventional dermoscopes are not user-friendly in terms of setup time and operations. Therefore, the development of an intelligent and handy system to assist the accurate screening and long-term monitoring of melanocytic skin lesions is crucial for early diagnosis and prevention of melanoma. In this paper, an advanced design of non-invasive and non-radioactive dermoscopy system was reported. Computer-aided simulations were conducted for optimizing the optical design and uniform illumination distribution. Functional prototype and the software system were further developed, which could enable image capturing at 10x amplified and general modes, convenient data transmission, analysis of dermoscopic features (e.g., asymmetry, border irregularity, color, diameter and dermoscopic structure) for assisting the early detection of melanoma, extract patient information (e.g. code, lesion location) and integrate with dermoscopic images, thus further support long term monitoring of diagnostic analysis results. A clinical trial study was further conducted on 185 Chinese children (0-18 years old). The results showed that for all subjects, skin conditions diagnosed based on the developed system accurately confirmed the diagnoses by conventional clinical procedures. Besides, clinical analysis on dermoscopic features and a potential standard approach by the developed system to support identifying specific melanocytic patterns for dermoscopic examination in Chinese children were also reported.

  7. Interdepartmental conflict management and negotiation in cardiovascular imaging.

    Science.gov (United States)

    Otero, Hansel J; Nallamshetty, Leelakrishna; Rybicki, Frank J

    2008-07-01

    Although the relationship between cardiologists and radiologists has a thorny history, advanced cardiac imaging technology and the promise of cardiac computed tomography are forcing both specialties back to the negotiation table. These discussions represent an opportunity for better communication, collaboration, and resource allocation. The authors address the aspects of interdepartmental conflict management and negotiation through their radiology department's ongoing efforts to provide high-quality advanced noninvasive cardiovascular imaging services at a large academic institution. The definition and causes of conflict are defined, with a specific focus on noninvasive cardiovascular imaging, followed by a description of steps used in the negotiation process. The authors encourage radiologists to entertain an open dialogue with cardiology, because in many cases, both sides can benefit. The benefits of a negotiated outcome include minimizing internal competitors, incorporating cardiologists' expertise to cardiac imaging algorithms, and more effective training opportunities.

  8. High angular resolution diffusion imaging : processing & visualization

    NARCIS (Netherlands)

    Prckovska, V.

    2010-01-01

    Diffusion tensor imaging (DTI) is a recent magnetic resonance imaging (MRI) technique that can map the orientation architecture of neural tissues in a completely non-invasive way by measuring the directional specificity (anisotropy) of the local water diffusion. However, in areas of complex fiber

  9. Clinical utility of three-dimensional contrast-enhanced ultrasound in the differentiation between noninvasive and invasive neoplasms of urinary bladder.

    Science.gov (United States)

    Li, Qiu-yang; Tang, Jie; He, En-hui; Li, Yan-mi; Zhou, Yun; Zhang, Xu; Chen, Guangfu

    2012-11-01

    The purpose of this study was to evaluate the effectiveness of three-dimensional contrast-enhanced ultrasound in differentiating invasive and noninvasive neoplasms of urinary bladder. A total of 60 lesions in 60 consecutive patients with bladder tumors received three dimensional ultrasonography, low acoustic power contrast enhanced ultrasonography and low acoustic power three-dimensional contrast-enhanced ultrasound examination. The IU22 ultrasound scanner and a volume transducer were used and the ultrasound contrast agent was SonoVue. The contrast-specific sonographic imaging modes were PI (pulse inversion) and PM (power modulation). The three dimensional ultrasonography, contrast enhanced ultrasonography, and three-dimensional contrast-enhanced ultrasound images were independently reviewed by two readers who were not in the images acquisition. Images were analyzed off-site. A level of confidence in the diagnosis of tumor invasion of the muscle layer was assigned on a 5° scale. Receiver operating characteristic analysis was used to assess overall confidence in the diagnosis of muscle invasion by tumor. Kappa values were used to assess inter-readers agreement. Histologic diagnosis was obtained for all patients. Final pathologic staging revealed 44 noninvasive tumors and 16 invasive tumors. Three-dimensional contrast-enhanced ultrasound depicted all 16 muscle-invasive tumors. The diagnostic performance of three-dimensional contrast-enhanced ultrasound was better than those of three dimensional ultrasonography and contrast enhanced ultrasonography. The receiver operating characteristic curves were 0.976 and 0.967 for three-dimensional contrast-enhanced ultrasound, those for three dimensional ultrasonography were 0.881 and 0.869, those for contrast enhanced ultrasonography were 0.927 and 0.929. The kappa values in the three dimensional ultrasonography, contrast enhanced ultrasonography and three-dimensional contrast-enhanced ultrasound for inter-reader agreements

  10. Clinical utility of three-dimensional contrast-enhanced ultrasound in the differentiation between noninvasive and invasive neoplasms of urinary bladder

    International Nuclear Information System (INIS)

    Li, Qiu-yang; Tang, Jie; He, En-hui; Li, Yan-mi; Zhou, Yun; Zhang, Xu; Chen, Guangfu

    2012-01-01

    Objectives: The purpose of this study was to evaluate the effectiveness of three-dimensional contrast-enhanced ultrasound in differentiating invasive and noninvasive neoplasms of urinary bladder. Methods: A total of 60 lesions in 60 consecutive patients with bladder tumors received three dimensional ultrasonography, low acoustic power contrast enhanced ultrasonography and low acoustic power three-dimensional contrast-enhanced ultrasound examination. The IU22 ultrasound scanner and a volume transducer were used and the ultrasound contrast agent was SonoVue. The contrast-specific sonographic imaging modes were PI (pulse inversion) and PM (power modulation). The three dimensional ultrasonography, contrast enhanced ultrasonography, and three-dimensional contrast-enhanced ultrasound images were independently reviewed by two readers who were not in the images acquisition. Images were analyzed off-site. A level of confidence in the diagnosis of tumor invasion of the muscle layer was assigned on a 5° scale. Receiver operating characteristic analysis was used to assess overall confidence in the diagnosis of muscle invasion by tumor. Kappa values were used to assess inter-readers agreement. Histologic diagnosis was obtained for all patients. Results: Final pathologic staging revealed 44 noninvasive tumors and 16 invasive tumors. Three-dimensional contrast-enhanced ultrasound depicted all 16 muscle-invasive tumors. The diagnostic performance of three-dimensional contrast-enhanced ultrasound was better than those of three dimensional ultrasonography and contrast enhanced ultrasonography. The receiver operating characteristic curves were 0.976 and 0.967 for three-dimensional contrast-enhanced ultrasound, those for three dimensional ultrasonography were 0.881 and 0.869, those for contrast enhanced ultrasonography were 0.927 and 0.929. The kappa values in the three dimensional ultrasonography, contrast enhanced ultrasonography and three-dimensional contrast-enhanced ultrasound

  11. Regional myocardial blood flow, metabolism and function assessed noninvasively by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Schelbert, H.R.; Phelps, M.E.; Hoffman, E.; Huang, S.; Kuhl, D.E.

    1979-01-01

    Positron emission computed tomography is a new technique for the noninvasive measure of myocardial blood flow, mechanical function and, in particular, metabolism. The capability of this new study means is due to the technological innovations of the imaging device and the availability of radioactive tracers that are specific for blood flow and metabolism. The device permits recording of cross-sectional images of the left ventricular myocardium that reflect quantitatively regional tracer tissue concentrations. By employing tracer kinetic models this new technique permits the measurement of regional glucose and fatty acid metabolism of the heart. While already an important new tool for investigative studies into cardiac physiology and pathophysiology, the clinical utility of positron emission tomography remains to be defined.

  12. Regional myocardial blood flow, metabolism and function assessed noninvasively by positron emission tomography

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.; Hoffman, E.; Huang, S.; Kuhl, D.E.

    1979-01-01

    Positron emission computed tomography is a new technique for the noninvasive measure of myocardial blood flow, mechanical function and, in particular, metabolism. The capability of this new study means is due to the technological innovations of the imaging device and the availability of radioactive tracers that are specific for blood flow and metabolism. The device permits recording of cross-sectional images of the left ventricular myocardium that reflect quantitatively regional tracer tissue concentrations. By employing tracer kinetic models this new technique permits the measurement of regional glucose and fatty acid metabolism of the heart. While already an important new tool for investigative studies into cardiac physiology and pathophysiology, the clinical utility of positron emission tomography remains to be defined

  13. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  14. Gold-195m first-pass radionuclide ventriculography, thallium-201 single-photon emission CT, and 12-lead ECG stress testing as a combined procedure

    International Nuclear Information System (INIS)

    Kipper, S.L.; Ashburn, W.L.; Norris, S.L.; Rimkus, D.S.; Dillon, W.A.

    1985-01-01

    Graded, sequential, rest/exercise, gold-195m, first-pass ventriculography and thallium-201 (Tl-201) single-photon emission computed tomography (SPECT) were performed simultaneously during a single, electrocardiograph-monitored, bicycle stress test in 24 individuals. The technical aspects and logistics involved in performing this combined radionuclide study are stressed in this preliminary report. Fourteen healthy volunteers each had a normal left ventricular ejection fraction and wall-motion response, along with normal T1-201 perfusion and washout, as determined by both visual and quantitative analysis of the tomographic sections. Each of ten patients with coronary artery disease had at least one abnormality of these parameters. The authors suggest that it is technically feasible to evaluate both cardiac function and myocardial perfusion simultaneously by combing Au-195m ventriculography and Tl-201 SPECT imaging into a single, noninvasive, diagnostic package

  15. Optical eye tracking system for real-time noninvasive tumor localization in external beam radiotherapy.

    Science.gov (United States)

    Via, Riccardo; Fassi, Aurora; Fattori, Giovanni; Fontana, Giulia; Pella, Andrea; Tagaste, Barbara; Riboldi, Marco; Ciocca, Mario; Orecchia, Roberto; Baroni, Guido

    2015-05-01

    External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring during ocular radiotherapy treatments. The

  16. Noninvasive optical diagnosis of low back pain with the aid of Chinese cupping procedure

    Science.gov (United States)

    Li, Nanxi; Li, Ting

    2018-02-01

    Low back pain (LBP) is a complex disease that can be cause by a variety of reasons. Now LBP has become a very common and severe disease among kinds of occupational groups with showing a younger trend. The traditional diagnosis relies on complicated imaging modalities and other dangerous and invasive methods. Noninvasive near-infrared spectroscopy (NIRS) is noninvasive and convenient, and has been successful used in point-of-care diagnosis. Here, we attempt to explore NIRS's application in in low back pain diagnosis and the effect of aid-use of Chinese cupping procedure. 13 LBP patients and 13 healthy subjects participated in NIRS measurements of concentrations of oxy- and deoxy-hemoglobins (Δ[HbO2] and Δ[Hb]) at the middle of the lumbar spine. It was showed that there was significant differences (p < 0.001) between healthy subjects and LBP patients after cupping procedure, while insignificant before cupping. Moreover, it was found that healthy subjects showed stronger responses to cupping procedure than LBP patients, with prominently higher concentration of Δ[HbO2] and Δ[Hb]. It indicates the potential of NIRS in noninvasive, measurable and straightforward monitoring/therapeutic effect evaluation of LBP with bedside and point-of-care monitoring capability.

  17. Non-invasive quantification of hepatic fat fraction by fast 1.0, 1.5 and 3.0 T MR imaging

    International Nuclear Information System (INIS)

    Schuchmann, Sebastian; Weigel, Christiane; Albrecht, Lothar; Kirsch, Michael; Lemke, Arne; Lorenz, Gerd; Warzok, Rolf; Hosten, Norbert

    2007-01-01

    Introduction: Even mild hepatic steatosis in a split liver donor may cause general liver failure and death in the donor. So far, CT density measurements or percutaneous biopsy is used to determine the presence of hepatic steatosis. Magnetic resonance imaging (MRI) may be an elegant method of non-invasive and non-radiation quantification of hepatic fat content. Methods: Fast gradient echo (GRE) technique was used to discriminate between fat and water spins. Echo time (TE) was adjusted for field strength dependent in-phase and out-of-phase states at 1.0, 1.5 and 3.0 T. Continuous MR signal transition from 100% water to 100% fat was investigated using a wedge water-oil phantom, which was positioned in such a way, that no spatial resolution occurred, thereby combining water and fat in one slice. Results: Using the phantom, a significant difference for a 5% difference in fat content was demonstrated in the range from 20 to 80% fat content (p 2 = 0.93 for TE 6 ms and r 2 = 0.91 for TE 10 ms). Conclusion: The described method can be used to determine the presence of hepatic steatosis of >10% with p < 0.05

  18. A study on new method of noninvasive esophageal venous pressure measurement based on the airflow and laser detection technology.

    Science.gov (United States)

    Hu, Chenghuan; Huang, Feizhou; Zhang, Rui; Zhu, Shaihong; Nie, Wanpin; Liu, Xunyang; Liu, Yinglong; Li, Peng

    2015-01-01

    Using optics combined with automatic control and computer real-time image detection technology, a novel noninvasive method of noncontact pressure manometry was developed based on the airflow and laser detection technology in this study. The new esophageal venous pressure measurement system was tested in-vitro experiments. A stable and adjustable pulse stream was produced from a self-developed pump and a laser emitting apparatus could generate optical signals which can be captured by image acquisition and analysis system program. A synchronization system simultaneous measured the changes of air pressure and the deformation of the vein wall to capture the vascular deformation while simultaneously record the current pressure value. The results of this study indicated that the pressure values tested by the new method have good correlation with the actual pressure value in animal experiments. The new method of noninvasive pressure measurement based on the airflow and laser detection technology is accurate, feasible, repeatable and has a good application prospects.

  19. Clinical and electrocardiographic evaluation during experimental toad poisoning in dogs

    Directory of Open Access Journals (Sweden)

    AC Camplesi

    2010-01-01

    Full Text Available Accidents involving toad poisoning are frequent and dogs are the most common victims; they become poisoned by biting or ingesting a toad. When released in the organism, the venom is absorbed by both the oral mucosa and the digestive tract, initiating its toxic action. The aim of this work was to evaluate the clinical and electrocardiographic aspects of dogs subjected to experimental toad poisoning, as well as their response to treatment with propranolol. Twenty dogs were divided into two groups, a control group (n = 5 and a poisoned group (n = 15. After general anesthesia, the control group received a placebo, while the poisoned group received a venom aliquot through an orogastric tube. Results were tested through multivariate analysis (p < 0.05. The animals in the poisoned group had gastrointestinal symptoms including emesis, intense salivation, hyperemic or congested oral mucosa and pasty diarrhea. Non-responsive mydriasis, nystagmus, depression, stupor, tachypnea, opisthotonus and ataxia were also manifested by 100% of the poisoned animals. Affected dogs had an increase in blood pressure, statistically significant throughout study. Five poisoned animals developed ventricular tachycardia and were treated with propranolol (0.5 mg/kg IV. All propranolol-treated animals returned to normal sinus rhythm, which evidences the efficacy of this drug to treat ventricular arrhythmias caused by toad venom.

  20. Techniques for Non-Invasive Monitoring of Arterial Blood Pressure

    Directory of Open Access Journals (Sweden)

    Agnes S. Meidert

    2018-01-01

    Full Text Available Since both, hypotension and hypertension, can potentially impair the function of vital organs such as heart, brain, or kidneys, monitoring of arterial blood pressure (BP is a mainstay of hemodynamic monitoring in acutely or critically ill patients. Arterial BP can either be obtained invasively via an arterial catheter or non-invasively. Non-invasive BP measurement provides either intermittent or continuous readings. Most commonly, an occluding upper arm cuff is used for intermittent non-invasive monitoring. BP values are then obtained either manually (by auscultation of Korotkoff sounds or palpation or automatically (e.g., by oscillometry. For continuous non-invasive BP monitoring, the volume clamp method or arterial applanation tonometry can be used. Both techniques enable the arterial waveform and BP values to be obtained continuously. This article describes the different techniques for non-invasive BP measurement, their advantages and limitations, and their clinical applicability.

  1. Radionuclide reporter gene imaging

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung Joon [School of Medicine, Chonnam National Univ., Gwangju (Korea, Republic of)

    2004-04-01

    Recent progress in the development of non-invasive imaging technologies continues to strengthen the role of molecular imaging biological research. These tools have been validated recently in variety of research models, and have been shown to provide continuous quantitative monitoring of the location(s), magnitude, and time-variation of gene expression. This article reviews the principles, characteristics, categories and the use of radionuclide reporter gene imaging technologies as they have been used in imaging cell trafficking, imaging gene therapy, imaging endogenous gene expression and imaging molecular interactions. The studies published to date demonstrate that reporter gene imaging technologies will help to accelerate model validation as well as allow for clinical monitoring of human diseases.

  2. Radionuclide reporter gene imaging

    International Nuclear Information System (INIS)

    Min, Jung Joon

    2004-01-01

    Recent progress in the development of non-invasive imaging technologies continues to strengthen the role of molecular imaging biological research. These tools have been validated recently in variety of research models, and have been shown to provide continuous quantitative monitoring of the location(s), magnitude, and time-variation of gene expression. This article reviews the principles, characteristics, categories and the use of radionuclide reporter gene imaging technologies as they have been used in imaging cell trafficking, imaging gene therapy, imaging endogenous gene expression and imaging molecular interactions. The studies published to date demonstrate that reporter gene imaging technologies will help to accelerate model validation as well as allow for clinical monitoring of human diseases

  3. Real time elastography - a non-invasive diagnostic method of small hepatocellular carcinoma in cirrhosis.

    Science.gov (United States)

    Gheorghe, Liana; Iacob, Speranta; Iacob, Razvan; Dumbrava, Mona; Becheanu, Gabriel; Herlea, Vlad; Gheorghe, Cristian; Lupescu, Ioana; Popescu, Irinel

    2009-12-01

    Small nodules (under 3 cm) detected on ultrasound (US) in cirrhotics represent the most challenging category for noninvasive diagnosis of hepatocellular carcinoma (HCC). To evaluate real-time sonoelastography as a noninvasive tool for the diagnosis of small HCC nodules in cirrhotic patients. 42 cirrhotic patients with 58 nodules (1-3 cm) were evaluated with real-time elastography (Hitachi EUB-6500); the mean intensity of colors red, blue, green were measured using a semi-quantitative method. Analysis of histograms for each color of the sonoelastography images was performed for quantifying the elasticity of nodule tissue in comparison with the cirrhotic liver tissue. AUROC curves were constructed to define the best cut-off points to distinguish malignant features of the nodules. Univariate and multivariate logistic regression analysis was performed. 595 sonoelastography images from 42 patients (25 men; 17 women) were analyzed. The mean age was 56.4 +/- 0.7 years and 69% patients were in Child-Pugh class A, 19% class B, 11% class C. For the mean intensity of green color AUROC=0.81, a cut-off value under 108.7 being diagnostic for HCC with a Sp=91.1%, Se=50%, PPV=92.1%, NPV=47.1%. Mean intensity of blue color proved to be an excellent diagnostic tool for HCC (AUROC=0.94); for a cut-off value greater than 128.9, Sp=92.2%, Se=78.9%, PPV=95.4%, NPV=68%. Independent predictive factors of HCC for a small nodule in cirrhotic patients were: blue color over 128.9 at sonoelastography and hypervascular appearance at Doppler US. US elastography is a promising method for the non-invasive diagnosis of early HCC. Blue color at elastography and hypervascular aspects are independent predictors of HCC.

  4. Non-invasive estimation of intracranial pressure. MR-based evaluation in children with hydrocephalus

    International Nuclear Information System (INIS)

    Muehlmann, M.; Steffinger, D.; Ertl-Wagner, B.; Koerte, I.K.; Peraud, A.; Lehner, M.; Heinen, F.; Alperin, N.

    2012-01-01

    The intracranial pressure (ICP) is a crucially important parameter for diagnostic and therapeutic decision-making in patients with hydrocephalus. So far there is no standard method to non-invasively assess the ICP. Various approaches to obtain the ICP semi-invasively or non-invasively are discussed and the clinical application of a magnetic resonance imaging (MRI)-based method to estimate ICP (MR-ICP) is demonstrated in a group of pediatric patients with hydrocephalus. Arterial inflow, venous drainage and craniospinal cerebrospinal fluid (CSF) flow were quantified using phase-contrast imaging to derive the MR-ICP. A total of 15 patients with hydrocephalus (n=9 treated with shunt placement or ventriculostomy) underwent MRI on a 3 T scanner applying retrospectively-gated cine phase contrast sequences. Of the patients six had clinical symptoms indicating increased ICP (age 2.5-14.61 years, mean 7.4 years) and nine patients had no clinical signs of elevated ICP (age 2.1-15.9 years; mean 9.8 years; all treated with shunt or ventriculostomy). Median MR-ICP in symptomatic patients was 24.5 mmHg (25th percentile 20.4 mmHg; 75th percentile 44.6 mmHg). Median MR-ICP in patients without acute signs of increased ICP was 9.8 mmHg (25th percentile 8.6 mmHg; 75th percentile 11.4 mmHg). Group differences were significant (p [de

  5. Automated Segmentation of Cardiac Magnetic Resonance Images

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Nilsson, Jens Chr.; Grønning, Bjørn A.

    2001-01-01

    Magnetic resonance imaging (MRI) has been shown to be an accurate and precise technique to assess cardiac volumes and function in a non-invasive manner and is generally considered to be the current gold-standard for cardiac imaging [1]. Measurement of ventricular volumes, muscle mass and function...

  6. Non-invasive imaging of tumors by monitoring autotaxin activity using an enzyme-activated near-infrared fluorogenic substrate.

    Directory of Open Access Journals (Sweden)

    Damian Madan

    Full Text Available Autotaxin (ATX, an autocrine motility factor that is highly upregulated in metastatic cancer, is a lysophospholipase D enzyme that produces the lipid second messenger lysophosphatidic acid (LPA from lysophosphatidylcholine (LPC. Dysregulation of the lysolipid signaling pathway is central to the pathophysiology of numerous cancers, idiopathic pulmonary fibrosis, rheumatoid arthritis, and other inflammatory diseases. Consequently, the ATX/LPA pathway has emerged as an important source of biomarkers and therapeutic targets. Herein we describe development and validation of a fluorogenic analog of LPC (AR-2 that enables visualization of ATX activity in vivo. AR-2 exhibits minimal fluorescence until it is activated by ATX, which substantially increases fluorescence in the near-infrared (NIR region, the optimal spectral window for in vivo imaging. In mice with orthotopic ATX-expressing breast cancer tumors, ATX activated AR-2 fluorescence. Administration of AR-2 to tumor-bearing mice showed high fluorescence in the tumor and low fluorescence in most healthy tissues with tumor fluorescence correlated with ATX levels. Pretreatment of mice with an ATX inhibitor selectively decreased fluorescence in the tumor. Together these data suggest that fluorescence directly correlates with ATX activity and its tissue expression. The data show that AR-2 is a non-invasive and selective tool that enables visualization and quantitation of ATX-expressing tumors and monitoring ATX activity in vivo.

  7. Noninvasive Localization of Accessory Pathways in Wolff-Parkinson-White Syndrome by Three-Dimensional Speckle Tracking Echocardiography.

    Science.gov (United States)

    Ishizu, Tomoko; Seo, Yoshihiro; Igarashi, Miyako; Sekiguchi, Yukio; Machino-Ohtsuka, Tomoko; Ogawa, Kojiro; Kuroki, Kenji; Yamamoto, Masahiro; Nogami, Akihiko; Kawakami, Yasushi; Aonuma, Kazutaka

    2016-06-01

    We have developed a noninvasive isochrone activation imaging (AI) system with 3-dimensional (3D) speckle tracking echocardiography (STE), which allows visualization of the wavefront image of mechanical propagation of the accessory pathway (ACP) in Wolff-Parkinson-White syndrome. Patients with manifest Wolff-Parkinson-White syndrome were imaged in 3D-STE AI mode, which quantified the time from QRS onset to regional endocardial deformation. In 2 patients with left- and right-side ACP, we confirmed that intraoperative contact endocardial electric mapping and the 3D-STE AI system showed comparable images pre- and postablation. In normal heart assessment by 3D-echo AI, the earliest activation sites were found at the attachment of the papillary muscles in the left ventricle and midseptum in the right ventricle, and none showed earliest activation at the peri-atrioventricular valve annuli. An analyzer who was unaware of the clinical information assessed 39 ACP locations in 38 Wolff-Parkinson-White syndrome patients using 3D-STE. All showed abnormal perimitral or tricuspid annular activations, and the location of 34 ACP (87%) showed agreement with the successful ablation sites within a 2-o'clock range. Especially for left free wall ACP, 17/18 (94%) showed consistency with the ablation site within a 2 o'clock range. Among 15 ACP at the ventricular septum, 9 (60%) showed early local activation in both right and left sides of the septum. Isochrone AI with 3D-STE may be a promising noninvasive imaging tool to assess cardiac synchronized activation in normal hearts and detect abnormal breakthrough of mechanical activation from both atrioventricular annuli in Wolff-Parkinson-White syndrome. © 2016 American Heart Association, Inc.

  8. A new CFD based non-invasive method for functional diagnosis of coronary stenosis.

    Science.gov (United States)

    Xie, Xinzhou; Zheng, Minwen; Wen, Didi; Li, Yabing; Xie, Songyun

    2018-03-22

    Accurate functional diagnosis of coronary stenosis is vital for decision making in coronary revascularization. With recent advances in computational fluid dynamics (CFD), fractional flow reserve (FFR) can be derived non-invasively from coronary computed tomography angiography images (FFR CT ) for functional measurement of stenosis. However, the accuracy of FFR CT is limited due to the approximate modeling approach of maximal hyperemia conditions. To overcome this problem, a new CFD based non-invasive method is proposed. Instead of modeling maximal hyperemia condition, a series of boundary conditions are specified and those simulated results are combined to provide a pressure-flow curve for a stenosis. Then, functional diagnosis of stenosis is assessed based on parameters derived from the obtained pressure-flow curve. The proposed method is applied to both idealized and patient-specific models, and validated with invasive FFR in six patients. Results show that additional hemodynamic information about the flow resistances of a stenosis is provided, which cannot be directly obtained from anatomy information. Parameters derived from the simulated pressure-flow curve show a linear and significant correlations with invasive FFR (r > 0.95, P < 0.05). The proposed method can assess flow resistances by the pressure-flow curve derived parameters without modeling of maximal hyperemia condition, which is a new promising approach for non-invasive functional assessment of coronary stenosis.

  9. Chemical imaging and solid state analysis at compact surfaces using UV imaging

    DEFF Research Database (Denmark)

    Wu, Jian X.; Rehder, Sönke; van den Berg, Frans

    2014-01-01

    and excipients in a non-invasive way, as well as mapping the glibenclamide solid state form. An exploratory data analysis supported the critical evaluation of the mapping results and the selection of model parameters for the chemical mapping. The present study demonstrated that the multi-wavelength UV imaging......Fast non-destructive multi-wavelength UV imaging together with multivariate image analysis was utilized to visualize distribution of chemical components and their solid state form at compact surfaces. Amorphous and crystalline solid forms of the antidiabetic compound glibenclamide...

  10. Assessment of lower extremity ischemia using smartphone thermographic imaging

    Directory of Open Access Journals (Sweden)

    Peter H. Lin, MD

    2017-12-01

    Full Text Available Conventional diagnostic modalities for assessing arterial circulation or tissue perfusion include blood pressure measurement, ultrasound evaluation, and contrast-based angiographic assessment. An infrared thermal camera can detect infrared radiation energy from the human body, which generates a thermographic image to allow tissue perfusion analysis. We describe a smartphone-based miniature thermal imaging system that can be used as an adjunctive imaging modality to assess tissue perfusion. This smartphone-based camera device is noninvasive, simple to use, and cost-effective in assessing patients with lower extremity tissue perfusion. Assessment of patients with lower extremity arterial ischemia can be performed by a variety of diagnostic modalities, including ankle-brachial index, absolute systolic ankle or toe pressure, transcutaneous oximetry, arterial Doppler waveform, arterial duplex ultrasound, computed tomography scan, arterial angiography, and thermal imaging. We herein describe a noninvasive imaging modality using smartphone-based infrared thermography.

  11. Enhancing the dynamic range of Ultrasound Imaging Velocimetry using interleaved imaging

    NARCIS (Netherlands)

    Poelma, C.; Fraser, K.H.

    2013-01-01

    In recent years, non-invasive velocity field measurement based on correlation of ultrasound images has been introduced as a promising technique for fundamental research into disease processes, as well as a diagnostic tool. A major drawback of the method is the relatively limited dynamic range when

  12. Non-invasive shallow seismic source comparison for hazardous waste site investigations

    International Nuclear Information System (INIS)

    Doll, W.E.

    1994-01-01

    Many commonly used shallow seismic sources are unacceptable for hazardous waste site investigations because they risk exhumation of contaminants in the soil, they add contaminants (e.g. lead) which are not allowed by regulations, or they add new migration paths for contaminants. Furthermore, recently developed high frequency vibrators for shallow investigations could be more effective at some sites than non-invasive impulsive sources because of their ability to tailor the source spectrum and reduce interference. The authors show preliminary results of a comparison test of eight non-invasive impulsive and swept sources in preparation for seismic reflection profiling on the Oak Ridge Reservation, Tennessee. Well log data are used to determine geologic contacts and to generate synthetic seismograms for the site. Common midpoint (CMP) seismic data for each source were collected at 95 geophone groups from 125 shot points along a 400m test line. Hydrophone data were obtained at 1.5m spacing between 61m and 133m depth in a hole near the center of the CMP line. As of March, 1994, brute stacks have been completed for three of the eight sources. Depth penetration is demonstrated in brute stacks and shot gathers, which show a 200ms reflector for all of the sources tested along portions of the line. Source effectiveness will also be evaluated by comparing images of several shallower reflectors (40--150ms) which are apparent in many of the records. Imaging of these reflectors appears to depend upon the ability of the source to generate sufficient high frequency energy (>100 Hz)

  13. Postoperative evaluation of surgical procedures in congenital heart disease with MR imaging

    International Nuclear Information System (INIS)

    Seelos, K.C.; Kersting-Sommerhoff, B.; Higgins, C.B.

    1989-01-01

    This paper reports on a study in which electrocardiographically gated spin-echo MR imaging was used to evaluate 23 patients with congenital heart disease who had undergone Waterston (n = 3), Potts (n = 2), Senning (n = 3), Fontan (n = 3), Rastelli (n = 4), Damus (n = 1) and Jatene (n = 7) procedures. Surgical shunts, conduits, or baffles were identified correctly in all patients. Patency, atresia and hypoplasia of central pulmonary arteries (PAs) as well as postoperative complications (focal stenosis of PAs, thrombosed pseudoaneurysm, intramural abscess) were diagnosed. MR findings were corroborated with angiography, echocardiography, and surgery. Narrowing of the right ventricular outflow tract and focal compression of the proximal PAs were recognized as specific complications of the Jatene procedure. MR imaging appears to be effective for the postoperative evaluation of surgical procedures used for congenital heart disease

  14. Presurgical mapping with magnetic source imaging. Comparisons with intraoperative findings

    International Nuclear Information System (INIS)

    Roberts, T.P.L.; Ferrari, P.; Perry, D.; Rowley, H.A.; Berger, M.S.

    2000-01-01

    We compare noninvasive preoperative mapping with magnetic source imaging to intraoperative cortical stimulation mapping. These techniques were directly compared in 17 patients who underwent preoperative and postoperative somatosensory mapping of a total of 22 comparable anatomic sites (digits, face). Our findings are presented in the context of previous studies that used magnetic source imaging and functional magnetic resonance imaging as noninvasive surrogates of intraoperative mapping for the identification of sensorimotor and language-specific brain functional centers in patients with brain tumors. We found that magnetic source imaging results were reasonably concordant with intraoperative mapping findings in over 90% of cases, and that concordance could be defined as 'good' in 77% of cases. Magnetic source imaging therefore provides a viable, if coarse, identification of somatosensory areas and, consequently, can guide and reduce the time taken for intraoperative mapping procedures. (author)

  15. Treatment of Neck Pain: Noninvasive Interventions

    Science.gov (United States)

    Carragee, Eugene J.; van der Velde, Gabrielle; Carroll, Linda J.; Nordin, Margareta; Guzman, Jaime; Peloso, Paul M.; Holm, Lena W.; Côté, Pierre; Hogg-Johnson, Sheilah; Cassidy, J. David; Haldeman, Scott

    2008-01-01

    Study Design. Best evidence synthesis. Objective. To identify, critically appraise, and synthesize literature from 1980 through 2006 on noninvasive interventions for neck pain and its associated disorders. Summary of Background Data. No comprehensive systematic literature reviews have been published on interventions for neck pain and its associated disorders in the past decade. Methods. We systematically searched Medline and screened for relevance literature published from 1980 through 2006 on the use, effectiveness, and safety of noninvasive interventions for neck pain and associated disorders. Consensus decisions were made about the scientific merit of each article; those judged to have adequate internal validity were included in our best evidence synthesis. Results. Of the 359 invasive and noninvasive intervention articles deemed relevant, 170 (47%) were accepted as scientifically admissible, and 139 of these related to noninvasive interventions (including health care utilization, costs, and safety). For whiplash-associated disorders, there is evidence that educational videos, mobilization, and exercises appear more beneficial than usual care or physical modalities. For other neck pain, the evidence suggests that manual and supervised exercise interventions, low-level laser therapy, and perhaps acupuncture are more effective than no treatment, sham, or alternative interventions; however, none of the active treatments was clearly superior to any other in either the short-or long-term. For both whiplash-associated disorders and other neck pain without radicular symptoms, interventions that focused on regaining function as soon as possible are relatively more effective than interventions that do not have such a focus. Conclusion. Our best evidence synthesis suggests that therapies involving manual therapy and exercise are more effective than alternative strategies for patients with neck pain; this was also true of therapies which include educational interventions

  16. Technology challenges in small animal PET imaging

    International Nuclear Information System (INIS)

    Lecomte, Roger

    2004-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging modality allowing biochemical processes to be investigated in vivo with sensitivity in the picomolar range. For this reason, PET has the potential to play a major role in the emerging field of molecular imaging by enabling the study of molecular pathways and genetic processes in living animals non-invasively. The challenge is to obtain a spatial resolution that is appropriate for rat and mouse imaging, the preferred animal models for research in biology, while achieving a sensitivity adequate for real-time measurement of rapid dynamic processes in vivo without violating tracer kinetic principles. An overview of the current state of development of dedicated small animal PET scanners is given, and selected applications are reported and discussed with respect to performance and significance to research in biology

  17. Visualization, imaging and new preclinical diagnostics in radiation oncology

    International Nuclear Information System (INIS)

    Cyran, Clemens C; Reiser, Maximilian F; Belka, Claus; Niyazi, Maximilian; Paprottka, Philipp M; Eisenblätter, Michel; Clevert, Dirk A; Rist, Carsten; Nikolaou, Konstantin; Lauber, Kirsten; Wenz, Frederik; Hausmann, Daniel

    2014-01-01

    Innovative strategies in cancer radiotherapy are stimulated by the growing knowledge on cellular and molecular tumor biology, tumor pathophysiology, and tumor microenvironment. In terms of tumor diagnostics and therapy monitoring, the reliable delineation of tumor boundaries and the assessment of tumor heterogeneity are increasingly complemented by the non-invasive characterization of functional and molecular processes, moving preclinical and clinical imaging from solely assessing tumor morphology towards the visualization of physiological and pathophysiological processes. Functional and molecular imaging techniques allow for the non-invasive characterization of tissues in vivo, using different modalities, including computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, positron emission tomography (PET) and optical imaging (OI). With novel therapeutic concepts combining optimized radiotherapy with molecularly targeted agents focusing on tumor cell proliferation, angiogenesis, and cell death, the non-invasive assessment of tumor microcirculation and tissue water diffusion, together with strategies for imaging the mechanisms of cellular injury and repair is of particular interest. Characterizing the tumor microenvironment prior to and in response to irradiation will help to optimize the outcome of radiotherapy. These novel concepts of personalized multi-modal cancer therapy require careful pre-treatment stratification as well as a timely and efficient therapy monitoring to maximize patient benefit on an individual basis. Functional and molecular imaging techniques are key in this regard to open novel opportunities for exploring and understanding the underlying mechanisms with the perspective to optimize therapeutic concepts and translate them into a personalized form of radiotherapy in the near future

  18. Electrocardiographic and Blood Pressure Alterations During Electroconvulsive Therapy in Young Adults

    Directory of Open Access Journals (Sweden)

    Rumi Demetrio Ortega

    2002-01-01

    Full Text Available OBJECTIVE - To study cardiovascular alterations in young patients with no apparent organic disease who underwent electroconvulsive therapy. METHODS - The study comprised 47 healthy patients (22 males and 25 females with a mean age of 30.3 years, who underwent electroconvulsive therapy. Ambulatory blood pressure monitoring and continuous electrocardiographic monitoring (Holter monitor were performed during 24 hours. Blood pressure and heart rate were assessed 4 hours prior to electric shock administration, during electric shock administration, and 3 hours after electric shock administration. Arrhythmias and alterations in the ST segment in 24 hours were recorded. RESULTS - On electroconvulsive therapy, a significant increase in blood pressure and heart rate was observed and the measurements returned to basal values after 25 minutes. Three females had tracings with depression of the ST segment suggesting myocardial ischemia prior to and after electroconvulsive therapy. Coronary angiography was normal. No severe cardiac arrhythmias were diagnosed. CONCLUSION - 1 Electroconvulsive therapy is a safe therapeutic modality in psychiatry; 2 it causes a significant increase in blood pressure and heart rate; 3 it may be associated with myocardial ischemia in the absence of coronary obstructive disease; 4 electroconvulsive therapy was not associated with the occurrence of severe cardiac arrhythmias.

  19. Noninvasive characterization of fractional photothermolysis induced by ablative and non-ablative lasers with optical coherence tomography

    International Nuclear Information System (INIS)

    Tsai, M T; Chang, F Y; Lee, J D; Fan, C H; Yang, C H; Shen, S C; Yi, J Y

    2013-01-01

    In this study, an optical coherence tomography (OCT) system is implemented for the noninvasive characterization of photothermolysis in human skin induced by ablative fractional lasers (AFLs) and non-ablative fractional lasers (NAFLs). With OCT imaging, microthermal zones (MTZs) induced by fractional lasers can be noninvasively visualized, and the size of induced MTZs can be quantitatively evaluated. According to the OCT results, the center region of the induced MTZ corresponds to weaker backscattered intensity after the AFL exposure as a result of tissue volatilization by photon energy. In contrast, after the NAFL exposure, the skin tissue is damaged and coagulated but not volatilized, which causes the backscattered intensity of the induced MTZ enhanced in the OCT image. To further identify the photothermolysis induced by AFLs or NAFLs, the backscattered intensities of MTZs are compared with those of the untreated tissue from the OCT results. The statistical result shows a clear difference in scattering properties of photothermolysis induced by AFLs and NAFLs. Finally, the induced photodamage at various depths can also be quantitatively evaluated, enabling an investigation of the relationship between the photodamage and the depth. (paper)

  20. Accuracy assessment of Tri-plane B-mode ultrasound for non-invasive 3D kinematic analysis of knee joints.

    Science.gov (United States)

    Masum, Md Abdullah; Pickering, Mark; Lambert, Andrew; Scarvell, Jennie; Smith, Paul

    2014-08-26

    Currently the clinical standard for measuring the motion of the bones in knee joints with sufficient precision involves implanting tantalum beads into the bones. These beads appear as high intensity features in radiographs and can be used for precise kinematic measurements. This procedure imposes a strong coupling between accuracy and invasiveness. In this paper, a tri-plane B-mode ultrasound (US) based non-invasive approach is proposed for use in kinematic analysis of knee joints in 3D space. The 3D analysis is performed using image processing procedures on the 2D US slices. The novelty of the proposed procedure and its applicability to the unconstrained 3D kinematic analysis of knee joints is outlined. An error analysis for establishing the method's feasibility is included for different artificial compositions of a knee joint phantom. Some in-vivo and in-vitro scans are presented to demonstrate that US scans reveal enough anatomical details, which further supports the experimental setup used using knee bone phantoms. The error between the displacements measured by the registration of the US image slices and the true displacements of the respective slices measured using the precision mechanical stages on the experimental apparatus is evaluated for translation and rotation in two simulated environments. The mean and standard deviation of errors are shown in tabular form. This method provides an average measurement precision of less than 0.1 mm and 0.1 degrees, respectively. In this paper, we have presented a novel non-invasive approach to measuring the motion of the bones in a knee using tri-plane B-mode ultrasound and image registration. In our study, the image registration method determines the position of bony landmarks relative to a B-mode ultrasound sensor array with sub-pixel accuracy. The advantages of our proposed system over previous techniques are that it is non-invasive, does not require the use of ionizing radiation and can be used conveniently if

  1. Functional diffusion map: A noninvasive MRI biomarker for early stratification of clinical brain tumor response

    OpenAIRE

    Moffat, Bradford A.; Chenevert, Thomas L.; Lawrence, Theodore S.; Meyer, Charles R.; Johnson, Timothy D.; Dong, Qian; Tsien, Christina; Mukherji, Suresh; Quint, Douglas J.; Gebarski, Stephen S.; Robertson, Patricia L.; Junck, Larry R.; Rehemtulla, Alnawaz; Ross, Brian D.

    2005-01-01

    Assessment of radiation and chemotherapy efficacy for brain cancer patients is traditionally accomplished by measuring changes in tumor size several months after therapy has been administered. The ability to use noninvasive imaging during the early stages of fractionated therapy to determine whether a particular treatment will be effective would provide an opportunity to optimize individual patient management and avoid unnecessary systemic toxicity, expense, and treatment delays. We investiga...

  2. Two-photon microscopy for non-invasive, quantitative monitoring of stem cell differentiation.

    Directory of Open Access Journals (Sweden)

    William L Rice

    Full Text Available BACKGROUND: The engineering of functional tissues is a complex multi-stage process, the success of which depends on the careful control of culture conditions and ultimately tissue maturation. To enable the efficient optimization of tissue development protocols, techniques suitable for monitoring the effects of added stimuli and induced tissue changes are needed. METHODOLOGY/PRINCIPAL FINDINGS: Here, we present the quantitative use of two-photon excited fluorescence (TPEF and second harmonic generation (SHG as a noninvasive means to monitor the differentiation of human mesenchymal stem cells (hMSCs using entirely endogenous sources of contrast. We demonstrate that the individual fluorescence contribution from the intrinsic cellular fluorophores NAD(PH, flavoproteins and lipofuscin can be extracted from TPEF images and monitored dynamically from the same cell population over time. Using the redox ratio, calculated from the contributions of NAD(PH and flavoproteins, we identify distinct patterns in the evolution of the metabolic activity of hMSCs maintained in either propagation, osteogenic or adipogenic differentiation media. The differentiation of these cells is mirrored by changes in cell morphology apparent in high resolution TPEF images and by the detection of collagen production via SHG imaging. Finally, we find dramatic increases in lipofuscin levels in hMSCs maintained at 20% oxygen vs. those in 5% oxygen, establishing the use of this chromophore as a potential biomarker for oxidative stress. CONCLUSIONS/SIGNIFICANCE: In this study we demonstrate that it is possible to monitor the metabolic activity, morphology, ECM production and oxidative stress of hMSCs in a non-invasive manner. This is accomplished using generally available multiphoton microscopy equipment and simple data analysis techniques, such that the method can widely adopted by laboratories with a diversity of comparable equipment. This method therefore represents a powerful tool

  3. Myocardial thallium scintigraphy after dipyridamole injection. Application to the diagnosis and evaluation of coronary disease

    International Nuclear Information System (INIS)

    Foult, J.M.; Weinmann, P.; Moretti, J.L.; Le Guludec, D.; Faraggi, M.

    1992-01-01

    Myocardial thallium scintigraphy performed after intravenous injection of dipyridamole is a non-invasive method to diagnose and evaluate coronary disease.It be used as an alternative to post-exercise scintigraphy, both methods having similar sensitivity and specificity. The dipyridamole test is contraindicated in patients with a history of bronchospasm and uncontrolled angina pectoris. Close clinical and electrocardiographic monitoring is required. The wide use of tomographic techniques has notably improved this examination

  4. Non-invasive physical treatments for chronic/recurrent headache.

    NARCIS (Netherlands)

    Bronfort, G.; Nilsson, N.; Haas, M.; Evans, R.; Goldsmith, C. H.; Assendelft, W. J.; Bouter, L. M.

    2004-01-01

    BACKGROUND: Non-invasive physical treatments are often used to treat common types of chronic/recurrent headache. OBJECTIVES: To quantify and compare the magnitude of short- and long-term effects of non-invasive physical treatments for chronic/recurrent headaches. SEARCH STRATEGY: We searched the

  5. Non-invasive physical treatments for chronic/recurrent headache

    NARCIS (Netherlands)

    Brønfort, Gert; Haas, Mitchell; Evans, Roni L.; Goldsmith, Charles H.; Assendelft, Willem J.J.; Bouter, Lex M.

    2014-01-01

    Background: Non-invasive physical treatments are often used to treat common types of chronic/recurrent headache. Objectives: To quantify and compare the magnitude of short- and long-term effects of non-invasive physical treatments for chronic/recurrent headaches. Search methods: We searched the

  6. A preclinical model for noninvasive imaging of hypoxia-induced gene expression; comparison with an exogenous marker of tumor hypoxia

    Energy Technology Data Exchange (ETDEWEB)

    Wen Bixiu; Burgman, Paul; Zanzonico, Pat; O' Donoghue, Joseph; Li, Gloria C.; Ling, C. Clifton [Memorial Sloan-Kettering Cancer Center, Department of Medical Physics, New York (United States); Cai Shangde; Finn, Ron [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York (United States); Serganova, Inna [Memorial Sloan-Kettering Cancer Center, Department of Neurology, New York (United States); Blasberg, Ronald; Gelovani, Juri [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York (United States); Memorial Sloan-Kettering Cancer Center, Department of Neurology, New York (United States)

    2004-11-01

    Hypoxia is associated with tumor aggressiveness and is an important cause of resistance to radiation therapy and chemotherapy. Assays of tumor hypoxia could provide selection tools for hypoxia-modifying treatments. The purpose of this study was to develop and characterize a rodent tumor model with a reporter gene construct that would be transactivated by the hypoxia-inducible molecular switch, i.e., the upregulation of HIF-1. The reporter gene construct is the herpes simplex virus 1-thymidine kinase (HSV1-tk) fused with the enhanced green fluorescent protein (eGFP) under the regulation of an artificial hypoxia-responsive enhancer/promoter. In this model, tumor hypoxia would up-regulate HIF-1, and through the hypoxia-responsive promoter transactivate the HSV1-tkeGFPfusion gene. The expression of this reporter gene can be assessed with the {sup 124}I-labeled reporter substrate 2'-fluoro-2'-deoxy-1-{beta}-d-arabinofuranosyl-5-iodouracil ({sup 124}I-FIAU), which is phosphorylated by the HSV1-tk enzyme and trapped in the hypoxic cells. Animal positron emission tomography (microPET) and phosphor plate imaging (PPI) were used in this study to visualize the trapped {sup 124}I-FIAU, providing a distribution of the hypoxia-induced molecular events. The distribution of {sup 124}I-FIAU was also compared with that of an exogenous hypoxic cell marker, {sup 18}F-fluoromisonidazole (FMISO). Our results showed that {sup 124}I-FIAU microPET imaging of the hypoxia-induced reporter gene expression is feasible, and that the intratumoral distributions of {sup 124}I-FIAU and {sup 18}F-FMISO are similar. In tumor sections, detailed radioactivity distributions were obtained with PPI which also showed similarity between {sup 124}I-FIAU and {sup 18}F-FMISO. This reporter system is sufficiently sensitive to detect hypoxia-induced transcriptional activation by noninvasive imaging and might provide a valuable tool in studying tumor hypoxia and in validating existing and future

  7. Design and implementation of an electrocardiographical signal acquisition and digital processing system orientated to the detection of paroxysmal arrhythmias

    International Nuclear Information System (INIS)

    Braceli, Agustín Iriart; Morani, Jorge Exequiel

    2011-01-01

    This article describes the design, technical aspects and implementation of a device capable of acquiring electrocardiograph signals; visualize them in real time over a graphic liquid crystal display (GLCD), and the storage of these ECG registers on a SD memory card. It also details a noise suppression algorithm using the Wavelet Transform. This system was specially developed to cover some bankruptcy that presents actual Holters or ECG regarding the detection of paroxysmal arrhythmias. The contribution of this work is settled on its portability and low production cost. The filtering method used provides an ECG signal without any significant noise and appropriate to the diagnosis of cardiac pathologies.

  8. Design and implementation of an electrocardiographical signal acquisition and digital processing system orientated to the detection of paroxysmal arrhythmias

    Science.gov (United States)

    Iriart Braceli, Agustín; Exequiel Morani, Jorge

    2011-12-01

    This article describes the design, technical aspects and implementation of a device capable of acquiring electrocardiograph signals; visualize them in real time over a graphic liquid crystal display (GLCD), and the storage of these ECG registers on a SD memory card. It also details a noise suppression algorithm using the Wavelet Transform. This system was specially developed to cover some bankruptcy that presents actual Holters or ECG regarding the detection of paroxysmal arrhythmias. The contribution of this work is settled on its portability and low production cost. The filtering method used provides an ECG signal without any significant noise and appropriate to the diagnosis of cardiac pathologies.

  9. Effects of parenteral administration of enrofloxacin on electrocardiographic parameters in hospitalized dogs

    Directory of Open Access Journals (Sweden)

    Carlos Fernando Agudelo Ramírez

    2012-01-01

    Full Text Available The effect of enrofloxacin on the QT interval of the electrocardiogram was studied in 30 hospitalized dogs. The experimental group (n = 15 received enrofloxacin parenterally (subcutaneously at a dose of 5 mg/kg twice daily and amoxicillin-clavulanate intravenously at a dose of 22 mg/kg three times daily. The control group (n = 15 received only amoxicillin-clavulanate. Electrocardiography was carried out for 5 min once daily for 6 days. The QT interval was corrected by four different formulae. No differences were found between the two groups or within each group for the duration of the study. On the last day of the study the average QT interval for the control and experimental groups was 213.2 ms and 202.9 ms, respectively. Enrofloxacin did not cause prolongation of the QT or corrected QT intervals. We can conclude that the parenteral administration of enrofloxacin in non-cardiac dogs does not adversely affect the electrocardiographic indicators (no prolongation of the QT or corrected QT interval and does not induce ventricular arrhythmias. Parenteral use of enrofloxacin is thus safe and effective in non-cardiac dogs.

  10. Changes in electrocardiographic findings after closed thoracostomy in patients with spontaneous pneumothorax

    Science.gov (United States)

    Lee, Wonjae; Lee, Yoonje; Kim, Changsun; Choi, Hyuk Joong; Kang, Bossng; Lim, Tae Ho; Oh, Jaehoon; Kang, Hyunggoo; Shin, Junghun

    2017-01-01

    Objective We aimed to describe electrocardiographic (ECG) findings in spontaneous pneumothorax patients before and after closed thoracostomy. Methods This is a retrospective study which included patients with spontaneous pneumothorax who presented to an emergency department of a tertiary urban hospital from February 2005 to March 2015. The primary outcome was a difference in ECG findings between before and after closed thoracostomy. We specifically investigated the following ECG elements: PR, QRS, QTc, axis, ST segments, and R waves in each lead. The secondary outcomes were change in ST segment in any lead and change in axis after closed thoracostomy. Results There were two ECG elements which showed statistically significant difference after thoracostomy. With right pneumothorax volume of greater than 80%, QTc and the R waves in aVF and V5 significantly changed after thoracostomy. With left pneumothorax volume between 31% and 80%, the ST segment in V2 and the R wave in V1 significantly changed after thoracostomy. However, majority of ECG elements did not show statistically significant alteration after thoracostomy. Conclusion We found only minor changes in ECG after closed thoracostomy in spontaneous pneumothorax patients. PMID:28435901

  11. Electrocardiographic characteristics of atrioventricular block induced by tilt testing.

    Science.gov (United States)

    Zyśko, Dorota; Gajek, Jacek; Koźluk, Edward; Mazurek, Walentyna

    2009-02-01

    The electrocardiographic (ECG) characteristics of atrioventricular (AV) block during reflex syncope may be unique due to the presence of hypervagotonia. The aim of the present study was to define the ECG characteristics of the AV block induced by neurocardiogenic reflex provoked by tilt testing (TT). A series of 31 patients with presumed vasovagal syncope and AV block provoked by TT was studied. The duration of PP and PR interval, AV block grade and type, concomitant arrhythmias, and timing of the AV block occurrence were assessed. The AV block occurred at TT termination in 26 patients, in the recovery in 4 patients, and in both periods in 1 patient. Atrioventricular block was preceded by sinus slowing, and sinus rhythm during AV block was slow and instable. Mobitz I, 2:1 second-degree AV block, and advanced second-degree AV block were recognized in 35.5, 48.4, and 67.8% of patients, respectively. Third-degree AV block was diagnosed in 41.9% of patients. Twenty-one patients had at least two AV block forms. The most prevalent concomitant arrhythmia was junctional escape rhythm (61.3%). (i) The occurrence of the AV block during neurocardiogenic reaction induced by TT is always preceded by sinus rhythm slowing and usually by PR interval prolongation. (ii) The AV block provoked by TT usually occurs at TT termination, but may occur even in the recovery period in a supine position. Sometimes the AV block may be present both at TT termination and during the recovery period.

  12. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... abdomen is a safe, noninvasive test that uses sound waves to produce a clear picture of the ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... to a CD or uploaded to a digital cloud server. top of page What are some common ... over time. top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging ...

  15. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... the exam room. These items include: jewelry, watches, credit cards and hearing aids, all of which can ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... others nearby harm. These items include: jewelry, watches, credit cards and hearing aids, all of which can ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ...

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ... used for conventional x-rays and CT scanning. Risks The MRI examination poses almost no risk to ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ... than 30 minutes from the onset of symptoms. Risks The MRI examination poses almost no risk to ...

  19. An uncommon case of noninvasive ocular surface squamous ...

    African Journals Online (AJOL)

    We describe a rare case of noninvasive OSSN involving the entire cornea in a human immunodeficiency virus‑negative patient. The patient was successfully treated with no recurrence, after intact surgical removal, mitomycin C treatment, and cryotherapy. Keywords: Noninvasive ocular surface squamous neoplasia, ocular ...

  20. Image processing techniques for quantification and assessment of brain MRI

    NARCIS (Netherlands)

    Kuijf, H.J.

    2013-01-01

    Magnetic resonance imaging (MRI) is a widely used technique to acquire digital images of the human brain. A variety of acquisition protocols is available to generate images in vivo and noninvasively, giving great opportunities to study the anatomy and physiology of the human brain. In my thesis,