WorldWideScience

Sample records for nondestructive stereological estimation

  1. Nondestructive, stereological estimation of canopy surface area

    DEFF Research Database (Denmark)

    Wulfsohn, Dvora-Laio; Sciortino, Marco; Aaslyng, Jesper M.

    2010-01-01

    We describe a stereological procedure to estimate the total leaf surface area of a plant canopy in vivo, and address the problem of how to predict the variance of the corresponding estimator. The procedure involves three nested systematic uniform random sampling stages: (i) selection of plants from...... a canopy using the smooth fractionator, (ii) sampling of leaves from the selected plants using the fractionator, and (iii) area estimation of the sampled leaves using point counting. We apply this procedure to estimate the total area of a chrysanthemum (Chrysanthemum morifolium L.) canopy and evaluate both...... the time required and the precision of the estimator. Furthermore, we compare the precision of point counting for three different grid intensities with that of several standard leaf area measurement techniques. Results showed that the precision of the plant leaf area estimator based on point counting...

  2. Stereological estimation of nuclear volume in benign and atypical meningiomas

    DEFF Research Database (Denmark)

    Madsen, C; Schrøder, H D

    1993-01-01

    A stereological estimation of nuclear volume in benign and atypical meningiomas was made. The aim was to investigate whether this method could discriminate between these two meningeal neoplasms. The difference was significant and it was moreover seen that there was no overlap between the two groups....... The results demonstrate that atypical meningiomas can be distinguished from benign meningiomas by an objective stereological estimation of nuclear volume....

  3. Stereological estimation of surface area from digital images

    DEFF Research Database (Denmark)

    Ziegel, Johanna; Kiderlen, Markus

    2010-01-01

    A sampling design of local stereology is combined with a method from digital stereology to yield a novel estimator of surface area based on counts of configurations observed in a digitization of an isotropic 2- dimensional slice with thickness s. As a tool, a result of the second author and J....... Rataj on infinitesimal increase of volumes of morphological transforms is refined and used. The proposed surface area estimator is asymptotically unbiased in the case of sets contained in the ball centred at the origin with radius s and in the case of balls centred at the origin with unknown radius...

  4. Stereological estimation of nuclear volume in benign and atypical meningiomas

    DEFF Research Database (Denmark)

    Madsen, C; Schrøder, H D

    1993-01-01

    A stereological estimation of nuclear volume in benign and atypical meningiomas was made. The aim was to investigate whether this method could discriminate between these two meningeal neoplasms. The difference was significant and it was moreover seen that there was no overlap between the two groups...

  5. Stereological estimation of nuclear mean volume in invasive meningiomas

    DEFF Research Database (Denmark)

    Madsen, C; Schrøder, H D

    1996-01-01

    A stereological estimation of nuclear mean volume in bone and brain invasive meningiomas was made. For comparison the nuclear mean volume of benign meningiomas was estimated. The aim was to investigate whether this method could discriminate between these groups. We found that the nuclear mean...... volume in the bone and brain invasive meningiomas was larger than in the benign tumors. The difference was significant and moreover it was seen that there was no overlap between the two groups. In the bone invasive meningiomas the nuclear mean volume appeared to be larger inside than outside the bone....... No significant difference in nuclear mean volume was found between brain and bone invasive meningiomas. The results demonstrate that invasive meningiomas differ from benign meningiomas by an objective stereological estimation of nuclear mean volume (p

  6. STEREOLOGICAL ESTIMATION OF SURFACE AREA FROM DIGITAL IMAGES

    Directory of Open Access Journals (Sweden)

    Johanna Ziegel

    2011-05-01

    Full Text Available A sampling design of local stereology is combined with a method from digital stereology to yield a novel estimator of surface area based on counts of configurations observed in a digitization of an isotropic 2- dimensional slice with thickness s. As a tool, a result of the second author and J. Rataj on infinitesimal increase of volumes of morphological transforms is refined and used. The proposed surface area estimator is asymptotically unbiased in the case of sets contained in the ball centred at the origin with radius s and in the case of balls centred at the origin with unknown radius. For general shapes bounds for the asymptotic expected relative worst case error are given. A simulation example is discussed for surface area estimation based on 2×2×2-configurations.

  7. A note on stereological estimation of the volume-weighted second moment of particle volume

    DEFF Research Database (Denmark)

    Jensen, E B; Sørensen, Flemming Brandt

    1991-01-01

    It is shown that for a variety of biological particle shapes, the volume-weighted second moment of particle volume can be estimated stereologically using only the areas of particle transects, which can be estimated manually by point-counting....

  8. Abdominal fat volume estimation by stereology on CT: a comparison with manual planimetry.

    Science.gov (United States)

    Manios, G E; Mazonakis, M; Voulgaris, C; Karantanas, A; Damilakis, J

    2016-03-01

    To deploy and evaluate a stereological point-counting technique on abdominal CT for the estimation of visceral (VAF) and subcutaneous abdominal fat (SAF) volumes. Stereological volume estimations based on point counting and systematic sampling were performed on images from 14 consecutive patients who had undergone abdominal CT. For the optimization of the method, five sampling intensities in combination with 100 and 200 points were tested. The optimum stereological measurements were compared with VAF and SAF volumes derived by the standard technique of manual planimetry on the same scans. Optimization analysis showed that the selection of 200 points along with the sampling intensity 1/8 provided efficient volume estimations in less than 4 min for VAF and SAF together. The optimized stereology showed strong correlation with planimetry (VAF: r = 0.98; SAF: r = 0.98). No statistical differences were found between the two methods (VAF: P = 0.81; SAF: P = 0.83). The 95% limits of agreement were also acceptable (VAF: -16.5%, 16.1%; SAF: -10.8%, 10.7%) and the repeatability of stereology was good (VAF: CV = 4.5%, SAF: CV = 3.2%). Stereology may be successfully applied to CT images for the efficient estimation of abdominal fat volume and may constitute a good alternative to the conventional planimetric technique. Abdominal obesity is associated with increased risk of disease and mortality. Stereology may quantify visceral and subcutaneous abdominal fat accurately and consistently. The application of stereology to estimating abdominal volume fat reduces processing time. Stereology is an efficient alternative method for estimating abdominal fat volume.

  9. Estimation of fetal volume by magnetic resonance imaging and stereology.

    Science.gov (United States)

    Roberts, N; Garden, A S; Cruz-Orive, L M; Whitehouse, G H; Edwards, R H

    1994-11-01

    The current methods to monitor fetal growth in utero are based on ultrasound image measurements which, lacking a proper sampling methodology, may be biased to unknown degrees. The Cavalieri method of stereology guarantees the accurate estimation of the volume of an arbitrary object from a few systematic sections. Non-invasive scanning methods, and magnetic resonance imaging (MRI) in particular, are valuable tools to provide the necessary sections, and therefore offer interesting possibilities for unbiased quantification. This paper describes how to estimate fetal volume in utero with a coefficient of error of less than 5% in less than 5 min, from three or four properly sampled MRI scans. MRI was chosen because it does not use ionizing radiations on the one hand, and it offers a good image quality on the other. The impact of potential sources of bias such as fetal motion, chemical shift and partial voluming artefacts is discussed. The methods are illustrated on four subjects monitored between weeks 28 and 40 of gestation.

  10. Abdominal fat volume estimation by stereology on CT: a comparison with manual planimetry

    Energy Technology Data Exchange (ETDEWEB)

    Manios, G.E.; Mazonakis, M.; Damilakis, J. [University of Crete, Department of Medical Physics, Faculty of Medicine, Heraklion, Crete (Greece); Voulgaris, C.; Karantanas, A. [University of Crete, Department of Radiology, Faculty of Medicine, Heraklion, Crete (Greece)

    2016-03-15

    To deploy and evaluate a stereological point-counting technique on abdominal CT for the estimation of visceral (VAF) and subcutaneous abdominal fat (SAF) volumes. Stereological volume estimations based on point counting and systematic sampling were performed on images from 14 consecutive patients who had undergone abdominal CT. For the optimization of the method, five sampling intensities in combination with 100 and 200 points were tested. The optimum stereological measurements were compared with VAF and SAF volumes derived by the standard technique of manual planimetry on the same scans. Optimization analysis showed that the selection of 200 points along with the sampling intensity 1/8 provided efficient volume estimations in less than 4 min for VAF and SAF together. The optimized stereology showed strong correlation with planimetry (VAF: r = 0.98; SAF: r = 0.98). No statistical differences were found between the two methods (VAF: P = 0.81; SAF: P = 0.83). The 95 % limits of agreement were also acceptable (VAF: -16.5 %, 16.1 %; SAF: -10.8 %, 10.7 %) and the repeatability of stereology was good (VAF: CV = 4.5 %, SAF: CV = 3.2 %). Stereology may be successfully applied to CT images for the efficient estimation of abdominal fat volume and may constitute a good alternative to the conventional planimetric technique. (orig.)

  11. DNA-index and stereological estimation of nuclear volume in primary and metastatic malignant melanomas

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Kristensen, I B; Grymer, F

    1990-01-01

    The aim of this study was to investigate the relationship between physical nuclear volume and ploidy level in malignant melanomas, and to analyse the heterogeneity of these two parameters among primary and corresponding secondary tumours. Unbiased stereological estimates of nuclear volume can...

  12. Application of stereological methods to estimate post-mortem brain surface area using 3T MRI

    DEFF Research Database (Denmark)

    Furlong, Carolyn; García-Fiñana, Marta; Puddephat, Michael

    2013-01-01

    The Cavalieri and Vertical Sections methods of design based stereology were applied in combination with 3 tesla (i.e. 3T) Magnetic Resonance Imaging (MRI) to estimate cortical and subcortical volume, area of the pial surface, area of the grey-white matter boundary, and thickness of the cerebral...

  13. Intralesional and metastatic heterogeneity in malignant melanomas demonstrated by stereologic estimates of nuclear volume

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Erlandsen, M

    1990-01-01

    Regional variability of nuclear 3-dimensional size can be estimated objectively using point-sampled intercepts obtained from different, defined zones within individual neoplasms. In the present study, stereologic estimates of the volume-weighted mean nuclear volume, nuclear vv, within peripheral...... melanomas showed large interindividual variation. This finding emphasizes that unbiased estimates of nuclear vv are robust to regional heterogeneity of nuclear volume and thus suitable for purposes of objective, quantitative malignancy grading of melanomas....

  14. Digital stereology in neuropathology

    DEFF Research Database (Denmark)

    Kristiansen, Sarah Line Brøgger; Nyengaard, Jens Randel

    2012-01-01

    will therefore present the relevant stereological estimators for obtaining reliable quantitative structural data from brains and peripheral nerves when using digital light microscopy. It is discussed how to obtain brain and nerve fibre samples to fulfil the requirements for the estimators. A presentation......-dimensional structural knowledge. Accordingly, stereology is a science based on statistical sampling principles and geometric measures. The application of stereology to neuropathological studies allows the researcher to efficiently obtain a precise estimate of various structural quantities. This neuropathological review...

  15. Stereologic estimation of nucleolar volume in ocular melanoma

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Gamel, J W; McCurdy, J

    1993-01-01

    The aim of this study was to investigate the relationships between one-, two-, and three-dimensional histomorphometric estimators of nucleolar size in ordinary histologic sections of uveal melanomas from 144 patients. In addition, the prognostic value of the various size parameters was studied. T...

  16. Stereological Methods for Estimation of Total Number of Particles in ...

    African Journals Online (AJOL)

    In certain organs, like the brain, it is important to count the number of neurons associated with a particular function or region. The count gives an estimate of the electronic units available for a specific task or are endowed with a quantum of electrical energy. Similar studies can be extended in organs like the kidney, glands ...

  17. Stereological estimation of the mean and variance of nuclear volume from vertical sections

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt

    1991-01-01

    The application of assumption-free, unbiased stereological techniques for estimation of the volume-weighted mean nuclear volume, nuclear vv, from vertical sections of benign and malignant nuclear aggregates in melanocytic skin tumours is described. Combining sampling of nuclei with uniform...... probability in a physical disector and Cavalieri's direct estimator of volume, the unbiased, number-weighted mean nuclear volume, nuclear vN, of the same benign and malignant nuclear populations is also estimated. Having obtained estimates of nuclear volume in both the volume- and number distribution...... to the larger malignant nuclei. Finally, the variance in the volume distribution of nuclear volume is estimated by shape-independent estimates of the volume-weighted second moment of the nuclear volume, vv2, using both a manual and a computer-assisted approach. The working procedure for the description of 3-D...

  18. Estimation of absolute microglial cell numbers in mouse fascia dentata using unbiased and efficient stereological cell counting principles

    DEFF Research Database (Denmark)

    Wirenfeldt, Martin; Dalmau, Ishar; Finsen, Bente

    2003-01-01

    Stereology offers a set of unbiased principles to obtain precise estimates of total cell numbers in a defined region. In terms of microglia, which in the traumatized and diseased CNS is an extremely dynamic cell population, the strength of stereology is that the resultant estimate is unaffected...... of microglia, although with this thickness, the intensity of the staining is too high to distinguish single cells. Lectin histochemistry does not visualize microglia throughout the section and, accordingly, is not suited for the optical fractionator. The mean total number of Mac-1+ microglial cells...... in the unilateral dentate gyrus of the normal young adult male C57BL/6 mouse was estimated to be 12,300 (coefficient of variation (CV)=0.13) with a mean coefficient of error (CE) of 0.06. The perspective of estimating microglial cell numbers using stereology is to establish a solid basis for studying the dynamics...

  19. The proportionator: unbiased stereological estimation using biased automatic image analysis and non-uniform probability proportional to size sampling

    DEFF Research Database (Denmark)

    Gardi, Jonathan Eyal; Nyengaard, Jens Randel; Gundersen, Hans Jørgen Gottlieb

    2008-01-01

    examined, which in turn leads to any of the known stereological estimates, including size distributions and spatial distributions. The unbiasedness is not a function of the assumed relation between the weight and the structure, which is in practice always a biased relation from a stereological (integral......, the desired number of fields are sampled automatically with probability proportional to the weight and presented to the expert observer. Using any known stereological probe and estimator, the correct count in these fields leads to a simple, unbiased estimate of the total amount of structure in the sections...... geometric) point of view. The efficiency of the proportionator depends, however, directly on this relation to be positive. The sampling and estimation procedure is simulated in sections with characteristics and various kinds of noises in possibly realistic ranges. In all cases examined, the proportionator...

  20. Stereological estimates of nuclear volume in squamous cell carcinoma of the uterine cervix and its precursors

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Bichel, P; Jakobsen, A

    1991-01-01

    Using modern stereology, this study was carried out to obtain base-line data concerning three-dimensional, mean nuclear size in precancerous and invasive lesions of the uterine cervix. Unbiased estimates of the volume-weighted mean nuclear volume (nuclear vv) were obtained by point-sampling of nu......Using modern stereology, this study was carried out to obtain base-line data concerning three-dimensional, mean nuclear size in precancerous and invasive lesions of the uterine cervix. Unbiased estimates of the volume-weighted mean nuclear volume (nuclear vv) were obtained by point......-sampling of nuclear intercepts in 51 pre-treatment biopsies from patients with invasive squamous cell carcinomas (SCC). Vertical sections from 27 specimens with cervical intraepithelial neoplasia (CIN) grades I through III were also investigated, along with 10 CIN III associated with microinvasion (CIN III + M......). On average, nuclear vv was larger in SCC than in CIN III and CIN III + M together (2 P = 8.9 . 10(-5). A conspicuous overlap of nuclear vv existed between all investigated lesional groups. The reproducibility of estimates of nuclear vv in biopsies with SCC was acceptable (r = 0.85 and r = 0.84 in intra...

  1. Stereological estimation of the mean and variance of nuclear volume from vertical sections

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt

    1991-01-01

    The application of assumption-free, unbiased stereological techniques for estimation of the volume-weighted mean nuclear volume, nuclear vv, from vertical sections of benign and malignant nuclear aggregates in melanocytic skin tumours is described. Combining sampling of nuclei with uniform...... probability in a physical disector and Cavalieri's direct estimator of volume, the unbiased, number-weighted mean nuclear volume, nuclear vN, of the same benign and malignant nuclear populations is also estimated. Having obtained estimates of nuclear volume in both the volume- and number distribution...... of volume, a detailed investigation of nuclear size variability is possible. Benign and malignant nuclear populations show approximately the same relative variability with regard to nuclear volume, and the presented data are compatible with a simple size transformation from the smaller benign nuclei...

  2. Design-based stereological estimation of the total number of cardiac myocytes in histological sections

    DEFF Research Database (Denmark)

    Brüel, Annemarie; Nyengaard, Jens Randel

    2005-01-01

    in LM sections using design-based stereology. MATERIALS AND METHODS: From formalin-fixed left rat ventricles (LV) isotropic uniformly random sections were cut. The total number of myocyte nuclei per LV was estimated using the optical disector. Two-microm-thick serial paraffin sections were stained......BACKGROUND: Counting the total number of cardiac myocytes has not previously been possible in ordinary histological sections using light microscopy (LM) due to difficulties in defining the myocyte borders properly. AIM: To describe a method by which the total number of cardiac myocytes is estimated...... with antibodies against cadherin and type IV collagen to visualise the intercalated discs and the myocyte membranes, respectively. Using the physical disector in "local vertical windows" of the serial sections, the average number of nuclei per myocyte was estimated.RESULTS: The total number of myocyte nuclei...

  3. Intralesional and metastatic heterogeneity in malignant melanomas demonstrated by stereologic estimates of nuclear volume

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Erlandsen, M

    1990-01-01

    Regional variability of nuclear 3-dimensional size can be estimated objectively using point-sampled intercepts obtained from different, defined zones within individual neoplasms. In the present study, stereologic estimates of the volume-weighted mean nuclear volume, nuclear vv, within peripheral...... on average larger in the peripheral zones of primary melanomas, than nuclear vv in central zones (2p = 6.7 x 10(-4), whereas no zonal differences were demonstrated in metastatic lesions (2p = 0.21). A marked intraindividual variation was demonstrated between primary and corresponding secondary melanomas (2p...... melanomas showed large interindividual variation. This finding emphasizes that unbiased estimates of nuclear vv are robust to regional heterogeneity of nuclear volume and thus suitable for purposes of objective, quantitative malignancy grading of melanomas....

  4. Stereological estimates of nuclear volume in the prognostic evaluation of primary flat carcinoma in situ of the urinary bladder

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Jacobsen, F

    1991-01-01

    Primary, flat carcinoma in situ of the urinary bladder is rare and its behaviour is unpredictable. The aim of this retrospective study was to obtain base-line data and investigate the prognostic value of unbiased, stereological estimates of the volume-weighted mean nuclear volume, nuclear vv, in ...

  5. Stereological estimation of surface area and barrier thickness of fish gills in vertical sections.

    Science.gov (United States)

    Da Costa, Oscar T F; Pedretti, Ana Carolina E; Schmitz, Anke; Perry, Steven F; Fernandes, Marisa N

    2007-01-01

    Previous morphometric methods for estimation of the volume of components, surface area and thickness of the diffusion barrier in fish gills have taken advantage of the highly ordered structure of these organs for sampling and surface area estimations, whereas the thickness of the diffusion barrier has been measured orthogonally on perpendicularly sectioned material at subjectively selected sites. Although intuitively logical, these procedures do not have a demonstrated mathematical basis, do not involve random sampling and measurement techniques, and are not applicable to the gills of all fish. The present stereological methods apply the principles of surface area estimation in vertical uniform random sections to the gills of the Brazilian teleost Arapaima gigas. The tissue was taken from the entire gill apparatus of the right-hand or left-hand side (selected at random) of the fish by systematic random sampling and embedded in glycol methacrylate for light microscopy. Arches from the other side were embedded in Epoxy resin. Reference volume was estimated by the Cavalieri method in the same vertical sections that were used for surface density and volume density measurements. The harmonic mean barrier thickness of the water-blood diffusion barrier was calculated from measurements taken along randomly selected orientation lines that were sine-weighted relative to the vertical axis. The values thus obtained for the anatomical diffusion factor (surface area divided by barrier thickness) compare favourably with those obtained for other sluggish fish using existing methods.

  6. Unbiased stereological estimation of d-dimensional volume in Rn from an isotropic random slice through a fixed point

    DEFF Research Database (Denmark)

    Jensen, Eva B. Vedel; Kiêu, K

    1994-01-01

    Unbiased stereological estimators of d-dimensional volume in R(n) are derived, based on information from an isotropic random r-slice through a specified point. The content of the slice can be subsampled by means of a spatial grid. The estimators depend only on spatial distances. As a fundamental ...... lemma, an explicit formula for the probability that an isotropic random r-slice in R(n) through 0 hits a fixed point in R(n) is given....

  7. Blood capillary length estimation from three-dimensional microscopic data by image analysis and stereology.

    Science.gov (United States)

    Kubínová, Lucie; Mao, Xiao Wen; Janáček, Jiří

    2013-08-01

    Studies of the capillary bed characterized by its length or length density are relevant in many biomedical studies. A reliable assessment of capillary length from two-dimensional (2D), thin histological sections is a rather difficult task as it requires physical cutting of such sections in randomized directions. This is often technically demanding, inefficient, or outright impossible. However, if 3D image data of the microscopic structure under investigation are available, methods of length estimation that do not require randomized physical cutting of sections may be applied. Two different rat brain regions were optically sliced by confocal microscopy and resulting 3D images processed by three types of capillary length estimation methods: (1) stereological methods based on a computer generation of isotropic uniform random virtual test probes in 3D, either in the form of spatial grids of virtual "slicer" planes or spherical probes; (2) automatic method employing a digital version of the Crofton relations using the Euler characteristic of planar sections of the binary image; and (3) interactive "tracer" method for length measurement based on a manual delineation in 3D of the axes of capillary segments. The presented methods were compared in terms of their practical applicability, efficiency, and precision.

  8. STEREOLOGICAL ESTIMATION OF ITO CELLS FROM RAT LIVER USING THE OPTICAL FRACTIONATOR - A PRELIMINARY REPORT

    Directory of Open Access Journals (Sweden)

    Ricardo Marcos

    2011-05-01

    Full Text Available In the last two decades, much light has been shed on hepatic fibrosis, and the activation / proliferation of Ito cells (IC emerged to play a central role. Therefore, it is essential to have solid quantitative data in nonpathological statuses; yet, this data is scarce and confined to "number per area" or semiquantitative information. Moreover, the supposed heterogeneous distribution of IC in the hepatic lobule was never analysed with design-based (unbiased stereology. In the present study, the total number (N of IC in rat liver was estimated for the first time, by combining immunocytochemistry with the optical fractionator. Quantification was extended to the hepatocytes, to disclose the IC index, an often-used ratio in hepatology. Systematic uniform random liver sections were obtained from male Wistar rats (n = 3, and immunostained against glial fibrillary acidic protein (GFAP, a known specific marker for hepatic IC. For the first time, these were marked against GFAP in thick (30 μm paraffin sections. The estimated N of IC was 224E06; with a coefficient of error of 0.04 or 0.06, depending on the particular equation used (based on the so-called "quadratic approximation". The IC index was 91 IC/1000 hepatocytes. Concerning the lobular heterogeneity, it was proved the liver harbours a larger total number of periportal IC and hepatocytes.

  9. A novel approach to non-biased systematic random sampling: a stereologic estimate of Purkinje cells in the human cerebellum.

    Science.gov (United States)

    Agashiwala, Rajiv M; Louis, Elan D; Hof, Patrick R; Perl, Daniel P

    2008-10-21

    Non-biased systematic sampling using the principles of stereology provides accurate quantitative estimates of objects within neuroanatomic structures. However, the basic principles of stereology are not optimally suited for counting objects that selectively exist within a limited but complex and convoluted portion of the sample, such as occurs when counting cerebellar Purkinje cells. In an effort to quantify Purkinje cells in association with certain neurodegenerative disorders, we developed a new method for stereologic sampling of the cerebellar cortex, involving calculating the volume of the cerebellar tissues, identifying and isolating the Purkinje cell layer and using this information to extrapolate non-biased systematic sampling data to estimate the total number of Purkinje cells in the tissues. Using this approach, we counted Purkinje cells in the right cerebella of four human male control specimens, aged 41, 67, 70 and 84 years, and estimated the total Purkinje cell number for the four entire cerebella to be 27.03, 19.74, 20.44 and 22.03 million cells, respectively. The precision of the method is seen when comparing the density of the cells within the tissue: 266,274, 173,166, 167,603 and 183,575 cells/cm3, respectively. Prior literature documents Purkinje cell counts ranging from 14.8 to 30.5 million cells. These data demonstrate the accuracy of our approach. Our novel approach, which offers an improvement over previous methodologies, is of value for quantitative work of this nature. This approach could be applied to morphometric studies of other similarly complex tissues as well.

  10. An unbiased stereological method for efficiently quantifying the innervation of the heart and other organs based on total length estimations

    DEFF Research Database (Denmark)

    Mühlfeld, Christian; Papadakis, Tamara; Krasteva, Gabriela

    2010-01-01

    Quantitative information about the innervation is essential to analyze the structure-function relationships of organs. So far, there has been no unbiased stereological tool for this purpose. This study presents a new unbiased and efficient method to quantify the total length of axons in a given...... reference volume, illustrated on the left ventricle of the mouse heart. The method is based on the following steps: 1) estimation of the reference volume; 2) randomization of location and orientation using appropriate sampling techniques; 3) counting of nerve fiber profiles hit by a defined test area within...

  11. Blood Capillary Length Estimation from Three-Dimensional Microscopic Data by Image Analysis and Stereology

    Czech Academy of Sciences Publication Activity Database

    Kubínová, Lucie; Mao, X. W.; Janáček, Jiří

    2013-01-01

    Roč. 19, č. 4 (2013), s. 898-906 ISSN 1431-9276 R&D Projects: GA MŠk(CZ) ME09010; GA MŠk(CZ) LH13028; GA ČR(CZ) GAP108/11/0794 Institutional research plan: CEZ:AV0Z5011922 Institutional support: RVO:67985823 Keywords : capillaries * confocal microscopy * image analysis * length * rat brain * stereology Subject RIV: EA - Cell Biology Impact factor: 1.757, year: 2013

  12. Stereological analysis of spatial structures

    DEFF Research Database (Denmark)

    Hansen, Linda Vadgård

    The thesis deals with stereological analysis of spatial structures. One area of focus has been to improve the precision of well-known stereological estimators by including information that is available via automatic image analysis. Furthermore, the thesis presents a stochastic model for star......-shaped three-dimensional objects using the radial function. It appears that the model is highly fleksiblel in the sense that it can be used to describe an object with arbitrary irregular surface. Results on the distribution of well-known local stereological volume estimators are provided....

  13. Stereological estimation of nuclear volume and other quantitative histopathological parameters in the prognostic evaluation of supraglottic laryngeal squamous cell carcinoma

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Bennedbaek, O; Pilgaard, J

    1989-01-01

    The aim of this study was to investigate various approaches to the grading of malignancy in pre-treatment biopsies from patients with supraglottic laryngeal squamous cell carcinoma. The prospects of objective malignancy grading based on stereological estimation of the volume-weighted mean nuclear...... observers of the latter was poor in the material which consisted of 35 biopsy specimens. Unbiased estimates of nuclear Vv were on the average 385 microns3 (CV = 0.44), with more than 90% of the associated variance attributable to differences in nuclear Vv among individual lesions. Nuclear Vv was positively....... None of the investigated categorical and quantitative parameters (cutoff points = means) reached the level of significance with respect to prognostic value. However, nuclear Vv showed the best information concerning survival (2p = 0.08), and this estimator offers optimal features for objective...

  14. Stereological estimation of nuclear volume and other quantitative histopathological parameters in the prognostic evaluation of supraglottic laryngeal squamous cell carcinoma

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Bennedbaek, O; Pilgaard, J

    1989-01-01

    The aim of this study was to investigate various approaches to the grading of malignancy in pre-treatment biopsies from patients with supraglottic laryngeal squamous cell carcinoma. The prospects of objective malignancy grading based on stereological estimation of the volume-weighted mean nuclear...... volume, nuclear Vv, and nuclear volume fraction, Vv(nuc/tis), along with morphometrical 2-dimensional estimation of nuclear density index, NI, and mitotic activity index, MI, were investigated and compared with the current morphological, multifactorial grading system. The reproducibility among two...... observers of the latter was poor in the material which consisted of 35 biopsy specimens. Unbiased estimates of nuclear Vv were on the average 385 microns3 (CV = 0.44), with more than 90% of the associated variance attributable to differences in nuclear Vv among individual lesions. Nuclear Vv was positively...

  15. STEREOLOGICAL ANALYSIS OF SHAPE

    Directory of Open Access Journals (Sweden)

    Asger Hobolth

    2011-05-01

    Full Text Available This paper concerns the problem of making stereological inference about the shape variability in a population of spatial particles. Under rotational invariance the shape variability can be estimated from central planar sections through the particles. A simple, but flexible, parametric model for rotation invariant spatial particles is suggested. It is shown how the parameters of the model can be estimated from observations on central sections. The corresponding model for planar particles is also discussed in some detail.

  16. Stereological estimation of nuclear volume in benign and malignant melanocytic lesions of the skin. Inter- and intraobserver variability of malignancy grading

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Ottosen, P D

    1991-01-01

    The volume-weighted, mean nuclear volume (nuclear vv) may be estimated without any assumptions regarding nuclear shape using modern stereological techniques. As a part of an investigation concerning the prospects of nuclear vv for classification and malignancy grading of cutaneous melanocytic tum...

  17. Stereological estimate of the total number of neurons in spinal segment D9 of the red-eared turtle

    DEFF Research Database (Denmark)

    Walløe, Solveig; Nissen, Ulla Vig; Berg, Rune W

    2011-01-01

    The red-eared turtle is an important animal model for investigating the neural activity in the spinal circuit that generates motor behavior. However, basic anatomical features, including the number of neurons in the spinal segments involved, are unknown. In the present study, we estimate the total...... number of neurons in segment D9 of the spinal cord in the red-eared turtle (Trachemys scripta elegans) using stereological cell counting methods. In transverse spinal cord sections stained with modified Giemsa, motoneurons (MNs), interneurons (INs), and non-neuronal cells were distinguished according...... to location and morphology. Each cell type was then counted separately using an optical disector with the cell nucleus as counting item. The number of cells in segment D9 was as follows (mean ± SE): MNs, 2049 ± 74; INs, 16,135 ± 316; non-neuronal cells, 47,504 ± 478 (n = 6). These results provide the first...

  18. Stereological estimates of nuclear volume in normal germ cells and carcinoma in situ of the human testis

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Müller, J

    1990-01-01

    Carcinoma in situ of the testis may appear many years prior to the development of an invasive tumour. Using point-sampled intercepts, base-line data concerning unbiased stereological estimates of the volume-weighted mean nuclear volume (nuclear vV) were obtained in 50 retrospective serial...... testicular biopsies from 10 patients with carcinoma in situ. All but two patients eventually developed an invasive growth. Testicular biopsies from 10 normal adult individuals and five prepubertal boys were included as controls. Nuclear vV in testicular carcinoma in situ was significantly larger than...... that of morphologically normal spermatogonia (2P = 1.0 x 10(-19)), with only minor overlap. Normal spermatogonia from controls had, on average, smaller nuclear vV than morphologically normal spermatogonia in biopsies with ipsi- or contra-lateral carcinoma in situ (2P = 5.2 x 10(-3)). No difference in nuclear vV was found...

  19. Stereological estimates of nuclear volume and other quantitative variables in supratentorial brain tumors. Practical technique and use in prognostic evaluation

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Braendgaard, H; Chistiansen, A O

    1991-01-01

    The use of morphometry and modern stereology in malignancy grading of brain tumors is only poorly investigated. The aim of this study was to present these quantitative methods. A retrospective feasibility study of 46 patients with supratentorial brain tumors was carried out to demonstrate...... the practical technique. The continuous variables were correlated with the subjective, qualitative WHO classification of brain tumors, and the prognostic value of the parameters was assessed. Well differentiated astrocytomas (n = 14) had smaller estimates of the volume-weighted mean nuclear volume and mean...... nuclear profile area, than those of anaplastic astrocytomas (n = 13) (2p = 3.1.10(-3) and 2p = 4.8.10(-3), respectively). No differences were seen between the latter type of tumor and glioblastomas (n = 19). The nuclear index was of the same magnitude in all three tumor types, whereas the mitotic index...

  20. Nondestructive test for estimating strength of concrete in structure

    International Nuclear Information System (INIS)

    Nozaki, Yoshitsugu; Soshiroda, Tomozo

    1997-01-01

    Evaluation of the quality of concrete in structures, especially strength estimation is said to be one of the most important problem and needed to establish test method especial tv for non-destructive method in situ. The paper describes the nondestructive test to estimate strength of concrete. From experimental study using full scale model wall, strength estimating equations are proposed by ultra-sonic pulse velocity, rebound hardness of Schmidt hammer and combined with two methods. From statistical study of the results of experiments, errors of estimated strength by the proposed equations are suggested. The validity of the equations are verified by investigation for existing reinforced concrete buildings aged 20 - 50 years. And it was found from the statistical study that the strength estimating equations need to be corrected in applying to tons aged concrete, and correction factor to those squat ions were suggested. Furthermore the corrected proposed equations were verified by applying to buildings investigated the other case.

  1. THE APPLICATION OF STEREOLOGY METHOD FOR ESTIMATING THE NUMBER OF 3D BaTiO3 – CERAMIC GRAINS CONTACT SURFACES

    Directory of Open Access Journals (Sweden)

    Vojislav V Mitić

    2011-05-01

    Full Text Available Methods of stereological study are of great importance for structural research of electronic ceramic materials including BaTiO3-ceramic materials. The broad application of ceramics, based on barium-titanate, in advanced electronics nowadays demands a constant research of its structure, that through the correlation structureproperties, a fundamental in the basic materials properties prognosis triad (technology-structure-properties, leads to further prognosis and properties design of these ceramics. Microstructure properties of BaTiO3- ceramic material, expressed in grains' boundary contact, are of basic importance for electric properties of this material, particularly the capacity. In this paper, a significant step towards establishing control under capacitive properties of BaTiO3-ceramics is being done by estimating the number of grains contact surfaces. Defining an efficient stereology method for estimating the number of BaTiO3-ceramic grains contact surfaces, we have started from a mathematical model of mutual grains distribution in the prescribed volume of BaTiO3-ceramic sample. Since the real microstructure morphology of BaTiO3-ceramics is in some way disordered, spherical shaped grains, using computer-modelling methods, are approximated by polyhedra with a great number of small convex polygons. By dividing the volume of BaTiO3-ceramic sample with the definite number of parallel planes, according to a given pace, into the intersection plane a certain number of grains contact surfaces are identified. According to quantitative estimation of 2D stereological parameters the modelled 3D internal microstructure is obtained. Experiments were made by using the scanning electronic microscopy (SEM method with the ceramic samples prepared under pressing pressures up to 150 MPa and sintering temperature up to 1370°C while the obtained microphotographs were used as a base of confirming the validity of presented stereology method. This paper, by applying

  2. Sampling for stereology in lungs

    Directory of Open Access Journals (Sweden)

    J. R. Nyengaard

    2006-12-01

    Full Text Available The present article reviews the relevant stereological estimators for obtaining reliable quantitative structural data from the lungs. Stereological sampling achieves reliable, quantitative information either about the whole lung or complete lobes, whilst minimising the workload. Studies have used systematic random sampling, which has fixed and constant sampling probabilities on all blocks, sections and fields of view. For an estimation of total lung or lobe volume, the Cavalieri principle can be used, but it is not useful in estimating individual cell volume due to various effects from over- or underprojection. If the number of certain structures is required, two methods can be used: the disector and the fractionator. The disector method is a three-dimensional stereological probe for sampling objects according to their number. However, it may be affected on tissue deformation and, therefore, the fractionator method is often the preferred sampling principle. In this method, a known and predetermined fraction of an object is sampled in one or more steps, with the final step estimating the number. Both methods can be performed in a physical and optical manner, therefore enabling cells and larger lung structure numbers (e.g. number of alveoli to be estimated. Some estimators also require randomisation of orientation, so that all directions have an equal chance of being chosen. Using such isotropic sections, surface area, length, and diameter can be estimated on a Cavalieri set of sections. Stereology can also illustrate the potential for transport between two compartments by analysing the barrier width. Estimating the individual volume of cells can be achieved by local stereology using a two-step procedure that first samples lung cells using the disector and then introduces individual volume estimation of the sampled cells. The coefficient of error of most unbiased stereological estimators is a combination of variance from blocks, sections, fields

  3. DNA level and stereologic estimates of nuclear volume in squamous cell carcinomas of the uterine cervix. A comparative study with analysis of prognostic impact

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Bichel, P; Jakobsen, A

    1992-01-01

    Grading of malignancy in squamous cell carcinomas of the uterine cervix is based on qualitative, morphologic examination and suffers from poor reproducibility. Using modern stereology, unbiased estimates of the three-dimensional, volume-weighted mean nuclear volume (nuclear vv), were obtained...... in pretreatment biopsies from 51 patients treated for cervical cancer in clinical Stages I through III (mean age of 56 years, follow-up period greater than 5 years). In addition, conventional, two-dimensional morphometric estimates of nuclear and mitotic features were obtained. DNA indices (DI) were estimated...... carcinoma of the uterine cervix....

  4. DNA level and stereologic estimates of nuclear volume in squamous cell carcinomas of the uterine cervix. A comparative study with analysis of prognostic impact

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Bichel, P; Jakobsen, A

    1992-01-01

    Grading of malignancy in squamous cell carcinomas of the uterine cervix is based on qualitative, morphologic examination and suffers from poor reproducibility. Using modern stereology, unbiased estimates of the three-dimensional, volume-weighted mean nuclear volume (nuclear vv), were obtained...... in pretreatment biopsies from 51 patients treated for cervical cancer in clinical Stages I through III (mean age of 56 years, follow-up period greater than 5 years). In addition, conventional, two-dimensional morphometric estimates of nuclear and mitotic features were obtained. DNA indices (DI) were estimated...

  5. Stereological estimation of nuclear volume in benign melanocytic lesions and cutaneous malignant melanomas

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt

    1989-01-01

    a favorable prognosis. No significant differences in vV could be demonstrated among different noninvasive tumor types. Two-dimensional estimates only distinguished benign from malignant tumors with considerable overlap and with significantly varying influence from other factors among different benign lesional...

  6. Stereological estimation of total cell numbers in the human cerebral and cerebellar cortex

    DEFF Research Database (Denmark)

    Walløe, Solveig; Pakkenberg, Bente; Fabricius, Katrine

    2014-01-01

    estimates and were often very time-consuming. Within the last 20-30 years, it has become possible to rely on more advanced and unbiased methods. These methods have provided us with information about fetal brain development, differences in cell numbers between men and women, the effect of age on selected...

  7. Automatic sampling for unbiased and efficient stereological estimation using the proportionator in biological studies

    DEFF Research Database (Denmark)

    Gardi, Jonathan Eyal; Nyengaard, Jens Randel; Gundersen, Hans Jørgen Gottlieb

    2008-01-01

    Quantification of tissue properties is improved using the general proportionator sampling and estimation procedure: automatic image analysis and non-uniform sampling with probability proportional to size (PPS). The complete region of interest is partitioned into fields of view, and every field...... of view is given a weight (the size) proportional to the total amount of requested image analysis features in it. The fields of view sampled with known probabilities proportional to individual weight are the only ones seen by the observer who provides the correct count. Even though the image analysis...... cerebellum, total number of orexin positive neurons in transgenic mice brain, and estimating the absolute area and the areal fraction of β islet cells in dog pancreas.  The proportionator was at least eight times more efficient (precision and time combined) than traditional computer controlled sampling....

  8. Application of stereology to dermatological research

    DEFF Research Database (Denmark)

    Kamp, Søren; Jemec, Gregor Borut Ernst; Kemp, Kåre

    2009-01-01

    Stereology is a set of mathematical and statistical tools to estimate three-dimensional (3-D) characteristics of objects from regular two-dimensional (2-D) sections. In medicine and biology, it can be used to estimate features such as cell volume, cell membrane surface area, total length of blood...... vessels per volume tissue and total number of cells. The unbiased quantification of these 3-D features allows for a better understanding of morphology in vivo compared with 2-D methods. This review provides an introduction to the field of stereology with specific emphasis on the application of stereology...

  9. Stereological estimation of total cell numbers in the young human utricular macula

    DEFF Research Database (Denmark)

    Severinsen, Stig Avall; Sørensen, Mads Sølvsten; Kirkegaard, Mette

    2010-01-01

    Abstract Conclusion: There is no change in the total cell population and hair cell:supporting cell ratio in the human utricular macula from gestational week 16 and onwards, whereas the lower hair cell:supporting cell ratio and lower total number of cells in the youngest specimens indicate...... that the utricle is still differentiating and adding new cells at the 10th to 12th gestational week. Objectives: Archival temporal bones were investigated to quantify cell numbers in the utricular macula in fetuses and children. Methods: The age of the subjects ranged from gestational week 10 to 15 years....... The optical fractionator was used to estimate the total number of cells in the utricular macula. Results: The total cell number was found to be 143 000 in subjects older than gestational week 16. The number of hair cells and supporting cells did not change between the 16th gestational week and 15 years...

  10. Improving efficiency in stereology

    DEFF Research Database (Denmark)

    Keller, Kresten Krarup; Andersen, Ina Trolle; Andersen, Johnnie Bremholm

    2013-01-01

    of the study was to investigate the time efficiency of the proportionator and the autodisector on virtual slides compared with traditional methods in a practical application, namely the estimation of osteoclast numbers in paws from mice with experimental arthritis and control mice. Tissue slides were scanned......, a proportionator sampling and a systematic, uniform random sampling were simulated. We found that the proportionator was 50% to 90% more time efficient than systematic, uniform random sampling. The time efficiency of the autodisector on virtual slides was 60% to 100% better than the disector on tissue slides. We...... conclude that both the proportionator and the autodisector on virtual slides may improve efficiency of cell counting in stereology....

  11. Unbiased Stereologic Estimation of the Spatial Distribution of Paget’s Disease in the Human Temporal Bone

    DEFF Research Database (Denmark)

    Bloch, Sune Land; Sørensen, Mads Sølvsten

    2014-01-01

    remodeling around the inner ear space and to compare it with that of otosclerosis in a contemporary context of temporal bone dynamics. MATERIALS AND METHODS: From the temporal bone collection of Massachusetts Eye and Ear Infirmary, 15 of 29 temporal bones with Paget's disease were selected to obtain...... an independent sample. All volume distributions were obtained along the normal axis of capsular bone remodeling activity by the use of vector-based stereology. RESULTS: Pagetic bone remodeling was distributed centrifugally around the inner ear space at the individual and the general level. This pattern...

  12. Stereological estimation of ovarian volume and number of follicles in low dose of Vitex agnus castus treated mice

    OpenAIRE

    HAMIDIAN, Gholamreza; YAHYAVI, Fariba

    2014-01-01

    Vitex agnus castus (VAC) has been proven to have a wide range of biological activities. It is commonly used in the treatment of menstrual disorders resulting from corpus luteum deficiency, including premenstrual symptoms and spasmodic dysmenorrheal, for certain menopausal conditions, and for insufficient lactation. The aim of this study was to investigate the effects of low dose of VAC essential oil on ovarian volume and oocyte number in mice by stereological technique. In this study 10 young...

  13. Using biased image analysis for improving unbiased stereological number estimation - a pilot simulation study of the smooth fractionator

    DEFF Research Database (Denmark)

    Gardi, Jonathan Eyal; Nyengaard, Jens Randel; Gundersen, Hans Jørgen Gottlieb

    2006-01-01

    uniformly random sampling design and the ordinary simple random sampling design. The smooth protocol is performed using biased information from crude (but fully automatic) image analysis of the fields of view. The different design paradigms are compared using simulation in three different cell distributions......The smooth fractionator was introduced in 2002. The combination of a smoothing protocol with a computer-aided stereology tool provides better precision and a lighter workload. This study uses simulation to compare fractionator sampling based on the smooth design, the commonly used systematic...

  14. Confocal stereology and image analysis: methods for estimating geometrical characteristics of cells and tissues from three-dimensional confocal images

    Czech Academy of Sciences Publication Activity Database

    Kubínová, Lucie; Janáček, Jiří; Karen, Petr; Radochová, Barbora; Difato, Francesco; Krekule, Ivan

    2004-01-01

    Roč. 53, Suppl.1 (2004), s. S47-S55 ISSN 0862-8408 R&D Projects: GA ČR GA304/01/0257; GA ČR GA310/02/1470; GA AV ČR KJB6011309; GA AV ČR KJB5039302 Grant - others:SI - CZ(CZ) KONTAKT 001/2001 Institutional research plan: CEZ:AV0Z5011922 Keywords : confocal microscopy * image analysis * stereology Subject RIV: EA - Cell Biology Impact factor: 1.140, year: 2004

  15. DNA level and stereologic estimates of nuclear volume in squamous cell carcinomas of the uterine cervix. A comparative study with analysis of prognostic impact

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Bichel, P; Jakobsen, A

    1992-01-01

    Grading of malignancy in squamous cell carcinomas of the uterine cervix is based on qualitative, morphologic examination and suffers from poor reproducibility. Using modern stereology, unbiased estimates of the three-dimensional, volume-weighted mean nuclear volume (nuclear vv), were obtained...... in pretreatment biopsies from 51 patients treated for cervical cancer in clinical Stages I through III (mean age of 56 years, follow-up period greater than 5 years). In addition, conventional, two-dimensional morphometric estimates of nuclear and mitotic features were obtained. DNA indices (DI) were estimated...... of nuclear vv were only of marginal prognostic significance (2P = 0.07). However, Cox multivariate regression analysis showed independent prognostic value of patient age and nuclear vv along with clinical stage and DI. All other investigated variables were rejected from the model. A prognostic index...

  16. A non-destructive method for estimating onion leaf area

    Directory of Open Access Journals (Sweden)

    Córcoles J.I.

    2015-06-01

    Full Text Available Leaf area is one of the most important parameters for characterizing crop growth and development, and its measurement is useful for examining the effects of agronomic management on crop production. It is related to interception of radiation, photosynthesis, biomass accumulation, transpiration and gas exchange in crop canopies. Several direct and indirect methods have been developed for determining leaf area. The aim of this study is to develop an indirect method, based on the use of a mathematical model, to compute leaf area in an onion crop using non-destructive measurements with the condition that the model must be practical and useful as a Decision Support System tool to improve crop management. A field experiment was conducted in a 4.75 ha commercial onion plot irrigated with a centre pivot system in Aguas Nuevas (Albacete, Spain, during the 2010 irrigation season. To determine onion crop leaf area in the laboratory, the crop was sampled on four occasions between 15 June and 15 September. At each sampling event, eight experimental plots of 1 m2 were used and the leaf area for individual leaves was computed using two indirect methods, one based on the use of an automated infrared imaging system, LI-COR-3100C, and the other using a digital scanner EPSON GT-8000, obtaining several images that were processed using Image J v 1.43 software. A total of 1146 leaves were used. Before measuring the leaf area, 25 parameters related to leaf length and width were determined for each leaf. The combined application of principal components analysis and cluster analysis for grouping leaf parameters was used to reduce the number of variables from 25 to 12. The parameter derived from the product of the total leaf length (L and the leaf diameter at a distance of 25% of the total leaf length (A25 gave the best results for estimating leaf area using a simple linear regression model. The model obtained was useful for computing leaf area using a non-destructive

  17. Newsletter '76 in stereology

    International Nuclear Information System (INIS)

    Ondracek, G.

    1976-08-01

    The present newsletter on stereology deals with a brief outlook about stereological problems to be solved in the future, compares definitions in pattern recognition and stereology and exposes the main notions of mathematical morphology used in quantitative metallography. This includes the description of the main stereological equations relating the parameters describing the dimensional features to the parameters measured in plane sections as well as a special type of equation for practical uses by which the average fiber length in composite materials can be determined. In this context the methods of particle shape descriptions have been summarized and reviewed and an example is given, how particle size and shape distributions can be measured statistically by automatic feature analysis of morphometric sections. - The introduction of stereological microstructural parameters into microstructure - property equations opens the way to calculate the materials properties by a stereological microstructure analysis and extends the possibilities of the common microstructural quality control. This is demonstrated for WC-Co hard metals. (orig./GSC) [de

  18. Newsletter '77 in stereology

    International Nuclear Information System (INIS)

    Ondracek, G.

    1977-12-01

    There are three groups of contributions forming the present Newsletter in Stereology which are such of theoretical type, stereological activities in bio-sciences and quatitative image analysis in materials science. The report is introduced by two papers treating theoretical problems as the definition of particle size based on the total curvature and the definition of pattern recognition categories. It than follows a summarizing description and comparison of alternative techniques used to measure and conclude stereological parameters in bio-sciences. The discussion includes the sample preparation, semi- and complete automatic measuring procedures as well as the computation of primary data. The biological part ends by considering the use of those quantitative microscopical methods to investigate and classify foreign compounds inside the human liver stereologically. The materials science part reports about tests made on steel specimens to evaluate the accuracy of automatic microstructural analyses and about the use of image 'erosion' and 'dilatation' to measure microstructural parameters automatically. The last subject is part of a serie on morphology in quantitative metallography started in the previous Newsletter '76. The last paper on materials sciences considers the use of stereology and microstructural analysis in respect to a quality control, choosing WC-Co hardmetals as an example, where stereologically defined microstructural parameters do not serve only to describe microstructures quantitatively but also provide a usefull tool to determine properties indirectly. (orig.) [de

  19. No correlation between ultrasound placental grading at 31-34 weeks of gestation and a surrogate estimate of organ function at term obtained by stereological analysis.

    Science.gov (United States)

    Yin, T T; Loughna, P; Ong, S S; Padfield, J; Mayhew, T M

    2009-08-01

    We test the experimental hypothesis that early changes in the ultrasound appearance of the placenta reflect poor or reduced placental function. The sonographic (Grannum) grade of placental maturity was compared to placental function as expressed by the morphometric oxygen diffusive conductance of the villous membrane. Ultrasonography was used to assess the Grannum grade of 32 placentas at 31-34 weeks of gestation. Indications for the scans included a history of previous fetal abnormalities, previous fetal growth problems or suspicion of IUGR. Placentas were classified from grade 0 (most immature) to grade III (most mature). We did not exclude smokers or complicated pregnancies as we aimed to correlate the early appearance of mature placentas with placental function. After delivery, microscopical fields on formalin-fixed, trichrome-stained histological sections of each placenta were obtained by multistage systematic uniform random sampling. Using design-based stereological methods, the exchange surface areas of peripheral (terminal and intermediate) villi and their fetal capillaries and the arithmetic and harmonic mean thicknesses of the villous membrane (maternal surface of villous trophoblast to adluminal surface of vascular endothelium) were estimated. An index of the variability in thickness of this membrane, and an estimate of its oxygen diffusive conductance, were derived secondarily as were estimates of the mean diameters and total lengths of villi and fetal capillaries. Group comparisons were drawn using analysis of variance. We found no significant differences in placental volume or composition or in the dimensions or diffusive conductances of the villous membrane. Subsequent exclusion of smokers did not alter these main findings. Grannum grades at 31-34 weeks of gestation appear not to provide reliable predictors of the functional capacity of the term placenta as expressed by the surrogate measure, morphometric diffusive conductance.

  20. Fast and nondestructive method for leaf level chlorophyll estimation using hyperspectral LiDAR

    NARCIS (Netherlands)

    Nevalainen, O.; Hakala, T.; Suomalainen, J.M.; Mäkipää, R.; Peltoniemi, M.; Krooks, A.; Kaasalainen, S.

    2014-01-01

    We propose an empirical method for nondestructive estimation of chlorophyll in tree canopies. The first prototype of a full waveform hyperspectral LiDAR instrument has been developed by the Finnish Geodetic Institute (FGI). The instrument efficiently combines the benefits of passive and active

  1. Stereological comparison of oocyte recruitment and batch fecundity estimates from paraffin and resin sections using spawning albacore (Thunnus alalunga) ovaries as a case study

    Science.gov (United States)

    Saber, Sámar; Macías, David; Ortiz de Urbina, Josetxu; Kjesbu, Olav Sigurd

    2015-01-01

    Traditional histological protocols in marine fish reproductive laboratories using paraffin as the embedding medium are now increasingly being replaced with protocols using resin instead. These procedures entail different degrees of tissue shrinkage complicating direct comparisons of measurement results across laboratories or articles. In this work we selected ovaries of spawning Mediterranean albacore (Thunnus alalunga) as the subject of our study to address the issue of structural changes, by contrasting values on oocyte recruitment and final batch fecundity given from the same tissue samples in both paraffin and resin. A modern stereological method, the oocyte packing density (OPD) theory, was used supported by initial studies on ovarian tissue sampling and measurement design. Examples of differences in the volume fraction of oocyte stages, free space and connective tissue were found between the embedding media. Mean oocyte diameters were smaller in paraffin than in resin with differences ranging between 0.5% in primary growth and 24.3% in hydration (HYD) stage oocytes. Fresh oocyte measurements showed that oocytes shrank as a consequence of the embedding process, reaching the maximal degree of shrinkage for oocytes in the HYD stage (45.8% in paraffin and 26.5% in resin). In order to assess the effect of oocyte shrinkage on the OPD result, and thereby on relative batch fecundity (Fr), oocyte diameters corrected and uncorrected for shrinkage, were used for estimations. Statistical significant differences were found (P based on either oocytes in the germinal vesicle migration stage or HYD stage. As a valuable adjunct, the present use of the OPD theory made it possible to document that the oocyte recruitment of spawning ovaries of Mediterranean albacore followed the typical pattern of an asynchronous oocyte development and indeterminate fecundity.

  2. Non-destructive estimation of Oecophylla smaragdina colony biomass

    DEFF Research Database (Denmark)

    Pinkalski, Christian Alexander Stidsen; Offenberg, Joachim; Jensen, Karl-Martin Vagn

    in mango plantations in Darwin, Australia. The total nest volume of O. smaragdina colonies in a tree was related to the activity of the ants (R2=0.85), estimated as the density of ant trails in the tree. Subsequently, the relation between nest volume and ant biomass (R2=0.70) was added to enable...... a prediction of ant biomass directly from ant activity. With this combined regression the ant biomass in a tree equaled 244.5 g fresh mass*ant activity. Similarly, the number of workers in trees was estimated using the relationship between nest volume and worker numbers (R2=0.84). Based on the model, five O...

  3. A comparison of porosity analysis using 2D stereology estimates and 3D serial sectioning for additively manufactured Ti 6Al 2Sn 4Zr 2Mo alloy

    International Nuclear Information System (INIS)

    Ganti, Satya R.; Velez, Michael A.; Geier, Brian A.; Hayes, Brian J.; Turner, Bryan J.; Jenkins, Elizabeth J.

    2017-01-01

    Porosity is a typical defect in additively manufactured (AM) parts. Such defects limit the properties and performance of AM parts, and therefore need to be characterized accurately. Current methods for characterization of defects and microstructure rely on classical stereological methods that extrapolate information from two dimensional images. The automation of serial sectioning provides an opportunity to precisely and accurately quantify porosity in three dimensions in materials. In this work, we analyzed the porosity of an additively manufactured Ti 6Al 2Sn 4Zr 2Mo sample using Robo-Met.3D "r"e"g"i"s"t"e"r"e"d, an automated serial sectioning system. Image processing for three dimensional reconstruction of the serial-sectioned two dimensional images was performed using open source image analysis software (Fiji/ImageJ, Dream.3D, Paraview). The results from this 3D serial sectioning analysis were then compared to classical 2D stereological methods (Saltykov stereological theory). We found that for this dataset, the classical 2D methods underestimated the porosity size and distributions of the larger pores; a critical attribute to fatigue behavior of the AM part. The results suggest that acquiring experimental data with equipment such as Robo-Met.3D "r"e"g"i"s"t"e"r"e"d to measure the number and size of particles such as pores in a volume irrespective of knowing their shape is a better choice.

  4. EARLY HISTORY OF GEOMETRIC PROBABILITY AND STEREOLOGY

    Directory of Open Access Journals (Sweden)

    Magdalena Hykšová

    2012-03-01

    Full Text Available The paper provides an account of the history of geometric probability and stereology from the time of Newton to the early 20th century. It depicts the development of two parallel ways: on one hand, the theory of geometric probability was formed with minor attention paid to other applications than those concerning spatial chance games. On the other hand, practical rules of the estimation of area or volume fraction and other characteristics, easily deducible from geometric probability theory, were proposed without the knowledge of this branch. A special attention is paid to the paper of J.-É. Barbier published in 1860, which contained the fundamental stereological formulas, but remained almost unnoticed both by mathematicians and practicians.

  5. Non-destructive linear model for leaf area estimation in Vernonia ferruginea Less

    Directory of Open Access Journals (Sweden)

    MC. Souza

    Full Text Available Leaf area estimation is an important biometrical trait for evaluating leaf development and plant growth in field and pot experiments. We developed a non-destructive model to estimate the leaf area (LA of Vernonia ferruginea using the length (L and width (W leaf dimensions. Different combinations of linear equations were obtained from L, L2, W, W2, LW and L2W2. The linear regressions using the product of LW dimensions were more efficient to estimate the LA of V. ferruginea than models based on a single dimension (L, W, L2 or W2. Therefore, the linear regression “LA=0.463+0.676WL” provided the most accurate estimate of V. ferruginea leaf area. Validation of the selected model showed that the correlation between real measured leaf area and estimated leaf area was very high.

  6. Cerebral atrophy in AIDS: a stereological study

    DEFF Research Database (Denmark)

    Oster, S; Christoffersen, P; Gundersen, H J

    1993-01-01

    Stereological estimates of mean volumes, surface areas, and cortical thicknesses were obtained on formalin-fixed brains from 19 men with AIDS and 19 controls. Volumes of neocortex, white matter, central brain nuclei, ventricles and archicortex were estimated using point counting and Cavalieri......'s unbiased principle for volume estimation. In AIDS, the mean volume of neocortex was reduced by 11%, and that of the central brain nuclei by 18%. Mean ventricular volume was increased by 55%. Mean neocortical thickness was reduced by 12%. The mean volume of white matter was reduced by 13%. The findings in 6...

  7. Feasibility of Residual Stress Nondestructive Estimation Using the Nonlinear Property of Critical Refraction Longitudinal Wave

    Directory of Open Access Journals (Sweden)

    Yu-Hua Zhang

    2017-01-01

    Full Text Available Residual stress has significant influence on the performance of mechanical components, and the nondestructive estimation of residual stress is always a difficult problem. This study applies the relative nonlinear coefficient of critical refraction longitudinal (LCR wave to nondestructively characterize the stress state of materials; the feasibility of residual stress estimation using the nonlinear property of LCR wave is verified. The nonlinear ultrasonic measurements based on LCR wave are conducted on components with known stress state to calculate the relative nonlinear coefficient. Experimental results indicate that the relative nonlinear coefficient monotonically increases with prestress and the increment of relative nonlinear coefficient is about 80%, while the wave velocity only decreases about 0.2%. The sensitivity of the relative nonlinear coefficient for stress is much higher than wave velocity. Furthermore, the dependence between the relative nonlinear coefficient and deformation state of components is found. The stress detection resolution based on the nonlinear property of LCR wave is 10 MPa, which has higher resolution than wave velocity. These results demonstrate that the nonlinear property of LCR wave is more suitable for stress characterization than wave velocity, and this quantitative information could be used for residual stress estimation.

  8. A New Form of Nondestructive Strength-Estimating Statistical Models Accounting for Uncertainty of Model and Aging Effect of Concrete

    International Nuclear Information System (INIS)

    Hong, Kee Jeung; Kim, Jee Sang

    2009-01-01

    As concrete ages, the surrounding environment is expected to have growing influences on the concrete. As all the impacts of the environment cannot be considered in the strength-estimating model of a nondestructive concrete test, the increase in concrete age leads to growing uncertainty in the strength-estimating model. Therefore, the variation of the model error increases. It is necessary to include those impacts in the probability model of concrete strength attained from the nondestructive tests so as to build a more accurate reliability model for structural performance evaluation. This paper reviews and categorizes the existing strength-estimating statistical models of nondestructive concrete test, and suggests a new form of the strength-estimating statistical models to properly reflect the model uncertainty due to aging of the concrete. This new form of the statistical models will lay foundation for more accurate structural performance evaluation.

  9. An ultrasonic methodology to non-destructively estimate the grain orientation in an anisotropic weld

    Directory of Open Access Journals (Sweden)

    Wirdelius Håkan

    2014-06-01

    Full Text Available The initial step towards a non-destructive technique that estimates grain orientation in an anisotropic weld is presented in this paper. The purpose is to aid future forward simulations of ultrasonic NDT of this kind of weld to achieve a better result. A forward model that consists of a weld model, a transmitter model, a receiver model and a 2D ray tracing algorithm is introduced. An inversion based on a multi-objective genetic algorithm is also presented. Experiments are conducted for both P and SV waves in order to collect enough data used in the inversion. Calculation is conducted to fulfil the estimation with both the synthetic data and the experimental data. Concluding remarks are presented at the end of the paper.

  10. Non-Destructive, Laser-Based Individual Tree Aboveground Biomass Estimation in a Tropical Rainforest

    Directory of Open Access Journals (Sweden)

    Muhammad Zulkarnain Abd Rahman

    2017-03-01

    Full Text Available Recent methods for detailed and accurate biomass and carbon stock estimation of forests have been driven by advances in remote sensing technology. The conventional approach to biomass estimation heavily relies on the tree species and site-specific allometric equations, which are based on destructive methods. This paper introduces a non-destructive, laser-based approach (terrestrial laser scanner for individual tree aboveground biomass estimation in the Royal Belum forest reserve, Perak, Malaysia. The study area is in the state park, and it is believed to be one of the oldest rainforests in the world. The point clouds generated for 35 forest plots, using the terrestrial laser scanner, were geo-rectified and cleaned to produce separate point clouds for individual trees. The volumes of tree trunks were estimated based on a cylinder model fitted to the point clouds. The biomasses of tree trunks were calculated by multiplying the volume and the species wood density. The biomasses of branches and leaves were also estimated based on the estimated volume and density values. Branch and leaf volumes were estimated based on the fitted point clouds using an alpha-shape approach. The estimated individual biomass and the total above ground biomass were compared with the aboveground biomass (AGB value estimated using existing allometric equations and individual tree census data collected in the field. The results show that the combination of a simple single-tree stem reconstruction and wood density can be used to estimate stem biomass comparable to the results usually obtained through existing allometric equations. However, there are several issues associated with the data and method used for branch and leaf biomass estimations, which need further improvement.

  11. Accuracy of Non-Destructive Testing of PBRs to Estimate Fragilities

    Science.gov (United States)

    Brune, J. N.; Brune, R.; Biasi, G. P.; Anooshehpoor, R.; Purvance, M.

    2011-12-01

    Prior studies of Precariously Balanced Rocks (PBRs) have involved various methods of documenting rock shapes and fragilities. These have included non-destructive testing (NDT) methods such as photomodeling, and potentially destructive testing (PDT) such as forced tilt tests. PDT methods usually have the potential of damaging or disturbing the rock or its pedestal so that the PBR usefulness for future generations is compromised. To date we have force-tilt tested approximately 28 PBRs, and of these we believe 7 have been compromised. We suggest here that given other inherent uncertainties in the current methodologies, NDT methods are now sufficiently advanced as to be adequate for the current state of the art use for comparison with Ground Motion Prediction Equations (GMPEs) and seismic hazard maps (SHMs). Here we compare tilt-test static toppling estimates to three non-destructive methods: (1) 3-D photographic modeling (2) profile analysis assuming the rock is 2-D, and (3) expert judgments from photographs. 3-D modeling uses the commercial Photomodeler program and photographs in the field taken from numerous directions around the rock. The output polyhedral shape is analyzed in Matlab determine the center of mass and in Autocad to estimate the static overturning angle alpha. For the 2-D method we chose the photograph in profile looking perpendicular to the estimated direction of toppling. The rock is outlined as a 2-D object in Matlab. Rock dimensions, rocking points, and a vertical reference are supplied by the photo analyst to estimate the center of gravity and static force overturning angles. For the expert opinion method we used additional photographs taken from different directions to improve the estimates of the center of mass and the rocking points. We used 7 rocks for comparisons. The error in estimating tan alpha from 3-D modeling is about 0.05. For 2-D estimates an average error is about 0.1 (?). For expert opinion estimates the error is about 0.06. For

  12. Efficient stereological approaches for the volumetry of a normal or enlarged spleen from MDCT images

    Energy Technology Data Exchange (ETDEWEB)

    Mazonakis, Michalis; Stratakis, John; Damilakis, John [University of Crete, Department of Medical Physics, Faculty of Medicine, P.O. Box 2208, Iraklion, Crete (Greece)

    2015-06-01

    To introduce efficient stereological approaches for estimating the volume of a normal or enlarged spleen from MDCT. All study participants underwent an abdominal MDCT. The first group included 20 consecutive patients with splenomegaly and the second group consisted of 20 subjects with a normal spleen. Splenic volume estimations were performed using the stereological point counting method. Stereological assessments were optimized using the systematic slice sampling procedure. Planimetric measurements based on manual tracing of splenic boundaries on each slice were taken as reference values. Stereological analysis using five to eight systematically sampled slices provided enlarged splenic volume estimations with a mean precision of 4.9 ± 1.0 % in a mean time of 2.3 ± 0.4 min. A similar measurement duration and error was observed for normal splenic volume assessment using four to seven systematically selected slices. These stereological approaches slightly but insignificantly overestimated the volume of a normal and enlarged spleen compared to planimetry (P > 0.05) with a mean difference of -1.3 ± 4.3 % and -2.7 ± 5.2 %, respectively. The two methods were highly correlated (r ≥ 0.96). The variability of repeated stereological estimations was below 3.8 %. The proposed stereological approaches enable the rapid, reproducible, and accurate splenic volume estimation from MDCT data in patients with or without splenomegaly. (orig.)

  13. Non-Destructive Lichen Biomass Estimation in Northwestern Alaska: A Comparison of Methods

    Science.gov (United States)

    Rosso, Abbey; Neitlich, Peter; Smith, Robert J.

    2014-01-01

    Terrestrial lichen biomass is an important indicator of forage availability for caribou in northern regions, and can indicate vegetation shifts due to climate change, air pollution or changes in vascular plant community structure. Techniques for estimating lichen biomass have traditionally required destructive harvesting that is painstaking and impractical, so we developed models to estimate biomass from relatively simple cover and height measurements. We measured cover and height of forage lichens (including single-taxon and multi-taxa “community” samples, n = 144) at 73 sites on the Seward Peninsula of northwestern Alaska, and harvested lichen biomass from the same plots. We assessed biomass-to-volume relationships using zero-intercept regressions, and compared differences among two non-destructive cover estimation methods (ocular vs. point count), among four landcover types in two ecoregions, and among single-taxon vs. multi-taxa samples. Additionally, we explored the feasibility of using lichen height (instead of volume) as a predictor of stand-level biomass. Although lichen taxa exhibited unique biomass and bulk density responses that varied significantly by growth form, we found that single-taxon sampling consistently under-estimated true biomass and was constrained by the need for taxonomic experts. We also found that the point count method provided little to no improvement over ocular methods, despite increased effort. Estimated biomass of lichen-dominated communities (mean lichen cover: 84.9±1.4%) using multi-taxa, ocular methods differed only nominally among landcover types within ecoregions (range: 822 to 1418 g m−2). Height alone was a poor predictor of lichen biomass and should always be weighted by cover abundance. We conclude that the multi-taxa (whole-community) approach, when paired with ocular estimates, is the most reasonable and practical method for estimating lichen biomass at landscape scales in northwest Alaska. PMID:25079228

  14. Non-destructive lichen biomass estimation in northwestern Alaska: a comparison of methods.

    Directory of Open Access Journals (Sweden)

    Abbey Rosso

    Full Text Available Terrestrial lichen biomass is an important indicator of forage availability for caribou in northern regions, and can indicate vegetation shifts due to climate change, air pollution or changes in vascular plant community structure. Techniques for estimating lichen biomass have traditionally required destructive harvesting that is painstaking and impractical, so we developed models to estimate biomass from relatively simple cover and height measurements. We measured cover and height of forage lichens (including single-taxon and multi-taxa "community" samples, n = 144 at 73 sites on the Seward Peninsula of northwestern Alaska, and harvested lichen biomass from the same plots. We assessed biomass-to-volume relationships using zero-intercept regressions, and compared differences among two non-destructive cover estimation methods (ocular vs. point count, among four landcover types in two ecoregions, and among single-taxon vs. multi-taxa samples. Additionally, we explored the feasibility of using lichen height (instead of volume as a predictor of stand-level biomass. Although lichen taxa exhibited unique biomass and bulk density responses that varied significantly by growth form, we found that single-taxon sampling consistently under-estimated true biomass and was constrained by the need for taxonomic experts. We also found that the point count method provided little to no improvement over ocular methods, despite increased effort. Estimated biomass of lichen-dominated communities (mean lichen cover: 84.9±1.4% using multi-taxa, ocular methods differed only nominally among landcover types within ecoregions (range: 822 to 1418 g m-2. Height alone was a poor predictor of lichen biomass and should always be weighted by cover abundance. We conclude that the multi-taxa (whole-community approach, when paired with ocular estimates, is the most reasonable and practical method for estimating lichen biomass at landscape scales in northwest Alaska.

  15. Non-destructive lichen biomass estimation in northwestern Alaska: a comparison of methods.

    Science.gov (United States)

    Rosso, Abbey; Neitlich, Peter; Smith, Robert J

    2014-01-01

    Terrestrial lichen biomass is an important indicator of forage availability for caribou in northern regions, and can indicate vegetation shifts due to climate change, air pollution or changes in vascular plant community structure. Techniques for estimating lichen biomass have traditionally required destructive harvesting that is painstaking and impractical, so we developed models to estimate biomass from relatively simple cover and height measurements. We measured cover and height of forage lichens (including single-taxon and multi-taxa "community" samples, n = 144) at 73 sites on the Seward Peninsula of northwestern Alaska, and harvested lichen biomass from the same plots. We assessed biomass-to-volume relationships using zero-intercept regressions, and compared differences among two non-destructive cover estimation methods (ocular vs. point count), among four landcover types in two ecoregions, and among single-taxon vs. multi-taxa samples. Additionally, we explored the feasibility of using lichen height (instead of volume) as a predictor of stand-level biomass. Although lichen taxa exhibited unique biomass and bulk density responses that varied significantly by growth form, we found that single-taxon sampling consistently under-estimated true biomass and was constrained by the need for taxonomic experts. We also found that the point count method provided little to no improvement over ocular methods, despite increased effort. Estimated biomass of lichen-dominated communities (mean lichen cover: 84.9±1.4%) using multi-taxa, ocular methods differed only nominally among landcover types within ecoregions (range: 822 to 1418 g m-2). Height alone was a poor predictor of lichen biomass and should always be weighted by cover abundance. We conclude that the multi-taxa (whole-community) approach, when paired with ocular estimates, is the most reasonable and practical method for estimating lichen biomass at landscape scales in northwest Alaska.

  16. The efficiency of systematic sampling in stereology-reconsidered

    DEFF Research Database (Denmark)

    Gundersen, Hans Jørgen Gottlieb; Jensen, Eva B. Vedel; Kieu, K

    1999-01-01

    In the present paper, we summarize and further develop recent research in the estimation of the variance of stereological estimators based on systematic sampling. In particular, it is emphasized that the relevant estimation procedure depends on the sampling density. The validity of the variance...... estimation is examined in a collection of data sets, obtained by systematic sampling. Practical recommendations are also provided in a separate section....

  17. Non-destructive estimation of leaf area for different plant ages and accessions of Capsicum annuum L.

    NARCIS (Netherlands)

    Swart, de E.A.M.; Groenwold, R.; Kanne, H.J.; Stam, P.; Marcelis, L.F.M.; Voorrips, R.E.

    2004-01-01

    Accurate measurements of leaf area are important for agronomic and physiological studies. To be able to perform repeated measurements of leaf area on single (genetically unique) plants, a method was developed to estimate leaf area from non-destructive measurements in Capsicum annuum L. independent

  18. Effect of Abiotic Stresses on the Nondestructive Estimation of Rice Leaf Nitrogen Concentration

    Directory of Open Access Journals (Sweden)

    Stephan M. Haefele

    2010-01-01

    Full Text Available Decision support tools for non-destructive estimation of rice crop nitrogen (N status (e.g., chlorophyll meter [SPAD] or leaf color chart [LCC] are an established technology for improved N management in irrigated systems, but their value in rainfed environments with frequent abiotic stresses remains untested. Therefore, we studied the effect of drought, salinity, phosphorus (P deficiency, and sulfur (S deficiency on leaf N estimates derived from SPAD and LCC measurements in a greenhouse experiment. Linear relations between chlorophyll concentration and leaf N concentration based on dry weight (Ndw between SPAD values adjusted for leaf thickness and Ndw and between LCC scores adjusted for leaf thickness and Ndw could be confirmed for all treatments and varieties used. Leaf spectral reflectance measurements did not show a stress-dependent change in the reflectance pattern, indicating that no specific element of the photosynthetic complex was affected by the stresses and at the stress level applied. We concluded that SPAD and LCC are potentially useful tools for improved N management in moderately unfavorable rice environments. However, calibration for the most common rice varieties in the target region is recommended to increase the precision of the leaf N estimates.

  19. Nondestructive Estimation of Muscle Contributions to STS Training with Different Loadings Based on Wearable Sensor System.

    Science.gov (United States)

    Liu, Kun; Liu, Yong; Yan, Jianchao; Sun, Zhenyuan

    2018-03-25

    Partial body weight support or loading sit-to-stand (STS) rehabilitation can be useful for persons with lower limb dysfunction to achieve movement again based on the internal residual muscle force and external assistance. To explicate how the muscles contribute to the kinetics and kinematics of STS performance by non-invasive in vitro detection and to nondestructively estimate the muscle contributions to STS training with different loadings, a wearable sensor system was developed with ground reaction force (GRF) platforms, motion capture inertial sensors and electromyography (EMG) sensors. To estimate the internal moments of hip, knee and ankle joints and quantify the contributions of individual muscle and gravity to STS movement, the inverse dynamics analysis on a simplified STS biomechanical model with external loading is proposed. The functional roles of the lower limb individual muscles (rectus femoris (RF), gluteus maximus (GM), vastus lateralis (VL), tibialis anterior (TA) and gastrocnemius (GAST)) during STS motion and the mechanism of the muscles' synergies to perform STS-specific subtasks were analyzed. The muscle contributions to the biomechanical STS subtasks of vertical propulsion, anteroposterior (AP) braking and propulsion for body balance in the sagittal plane were quantified by experimental studies with EMG, kinematic and kinetic data.

  20. Non-destructive examination and estimation of radioactivity levels for decorative building materials

    International Nuclear Information System (INIS)

    Mao Yahong; Liu Yigang; Lin Libin

    2003-01-01

    Measurement of gamma ray intensity from building materials can be substituted by measuring alpha rays following outline of a radionuclide decay. Exposure levels of alpha ray from the surface of decorative materials can be measured non-destructively by placing a detector on the surface of the materials. Authors have studied the relationship between gamma specific activities of natural radionuclides and alpha and beta ray level in building materials used in interior decoration, and the saturated thickness of beta ray from the surface of different materials. The results showed that the range of beta ray with the maximum energy in natural radioactive series is longer than thickness of a piece of decorative materials. So the exposure level of beta ray cannot be used to estimate the limit of external and internal indexes. The polynomial between exposure level of alpha ray from surface (α) and external index (I γ ) for granite is: I γ =0.38 + 49.84α + 288.24α 2 . The measured values were in accordance with the values from the polynomial within 95%. The polynomial between exposure level of alpha ray from surface (α) and external index (Iγ) for polishing tiles is: I γ =0.42 + 343.55α-32999.66α 2 . The measured values were in accordance with the values from the polynomial within 90%

  1. Applied tensor stereology

    DEFF Research Database (Denmark)

    Ziegel, Johanna; Nyengaard, Jens Randel; Jensen, Eva B. Vedel

    In the present paper, statistical procedures for estimating shape and orientation of arbitrary three-dimensional particles are developed. The focus of this work is on the case where the particles cannot be observed directly, but only via sections. Volume tensors are used for describing particle s...

  2. Systematic versus random sampling in stereological studies.

    Science.gov (United States)

    West, Mark J

    2012-12-01

    The sampling that takes place at all levels of an experimental design must be random if the estimate is to be unbiased in a statistical sense. There are two fundamental ways by which one can make a random sample of the sections and positions to be probed on the sections. Using a card-sampling analogy, one can pick any card at all out of a deck of cards. This is referred to as independent random sampling because the sampling of any one card is made without reference to the position of the other cards. The other approach to obtaining a random sample would be to pick a card within a set number of cards and others at equal intervals within the deck. Systematic sampling along one axis of many biological structures is more efficient than random sampling, because most biological structures are not randomly organized. This article discusses the merits of systematic versus random sampling in stereological studies.

  3. PLASTICITY OF SKELETAL MUSCLE STUDIED BY STEREOLOGY

    Directory of Open Access Journals (Sweden)

    Ida Eržen

    2011-05-01

    Full Text Available The present contribution provides an overview of stereological methods applied in the skeletal muscle research at the Institute of Anatomy of the Medical Faculty in Ljubljana. Interested in skeletal muscle plasticity we studied three different topics: (i expression of myosin heavy chain isoforms in slow and fast muscles under experimental conditions, (ii frequency of satellite cells in young and old human and rat muscles and (iii capillary supply of rat fast and slow muscles. We analysed the expression of myosin heavy chain isoforms within slow rat soleus and fast extensor digitorum longus muscles after (i homotopic and heterotopic transplantation of both muscles, (ii low frequency electrical stimulation of the fast muscle and (iii transposition of the fast nerve to the slow muscle. The models applied were able to turn the fast muscle into a completely slow muscle, but not vice versa. One of the indicators for the regenerative potential of skeletal muscles is its satellite cell pool. The estimated parameters, number of satellite cells per unit fibre length, corrected to the reference sarcomere length (Nsc/Lfib and number of satellite cells per number of nuclei (myonuclei and satellite cell nuclei (Nsc/Nnucl indicated that the frequency of M-cadherin stained satellite cells declines in healthy old human and rat muscles compared to young muscles. To access differences in capillary densities among slow and fast muscles and slow and fast muscle fibres, we have introduced Slicer and Fakir methods, and tested them on predominantly slow and fast rat muscles. Discussing three different topics that require different approach, the present paper reflects the three decades of the development of stereological methods: 2D analysis by simple point counting in the 70's, the disector in the 80's and virtual spatial probes in the 90's. In all methods the interactive computer assisted approach was utilised.

  4. Assessment of left ventricular function and mass by MR imaging: a stereological study based on the systematic slice sampling procedure.

    Science.gov (United States)

    Mazonakis, Michalis; Sahin, Bunyamin; Pagonidis, Konstantin; Damilakis, John

    2011-06-01

    The aim of this study was to combine the stereological technique with magnetic resonance (MR) imaging data for the volumetric and functional analysis of the left ventricle (LV). Cardiac MR examinations were performed in 13 consecutive subjects with known or suspected coronary artery disease. The end-diastolic volume (EDV), end-systolic volume, ejection fraction (EF), and mass were estimated by stereology using the entire slice set depicting LV and systematic sampling intensities of 1/2 and 1/3 that provided samples with every second and third slice, respectively. The repeatability of stereology was evaluated. Stereological assessments were compared with the reference values derived by manually tracing the endocardial and epicardial contours on MR images. Stereological EDV and EF estimations obtained by the 1/3 systematic sampling scheme were significantly different from those by manual delineation (P sampling intensity of 1/2 (P > .05). For these stereological approaches, a high correlation (r(2) = 0.80-0.93) and clinically acceptable limits of agreement were found with the reference method. Stereological estimations obtained by both sample sizes presented comparable coefficient of variation values of 2.9-5.8%. The mean time for stereological measurements on the entire slice set was 3.4 ± 0.6 minutes and it was reduced to 2.5 ± 0.5 minutes with the 1/2 systematic sampling scheme. Stereological analysis on systematic samples of MR slices generated by the 1/2 sampling intensity provided efficient and quick assessment of LV volumes, function, and mass. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  5. Objective malignancy grading of squamous cell carcinoma of the lung. Stereologic estimates of mean nuclear size are of prognostic value, independent of clinical stage of disease

    DEFF Research Database (Denmark)

    Ladekarl, M; Bæk-Hansen, T; Henrik-Nielsen, R

    1995-01-01

    a projection microscope and a simple test system in fields of vision systematically selected from the whole tumor area of one routine section, five quantitative histopathologic variables were estimated: the mean nuclear volume, the mean nuclear profile area, the density of nuclear profiles, the volume fraction...... of nuclei to tissue, and the number of mitotic profiles per 10(3) nuclear profiles. For each patient, information was recorded regarding sex, age at diagnosis, and clinical stage of disease.RESULTS: Single-factor analyses showed that a favorable prognosis was associated with early clinical stages (Stages I...... and II) and young age (P stage, age, and mean nuclear...

  6. Objective malignancy grading of squamous cell carcinoma of the lung. Stereologic estimates of mean nuclear size are of prognostic value, independent of clinical stage of disease

    DEFF Research Database (Denmark)

    Ladekarl, M; Bæk-Hansen, T; Henrik-Nielsen, R

    1995-01-01

    a projection microscope and a simple test system in fields of vision systematically selected from the whole tumor area of one routine section, five quantitative histopathologic variables were estimated: the mean nuclear volume, the mean nuclear profile area, the density of nuclear profiles, the volume fraction...... of nuclei to tissue, and the number of mitotic profiles per 10(3) nuclear profiles. For each patient, information was recorded regarding sex, age at diagnosis, and clinical stage of disease. RESULTS: Single-factor analyses showed that a favorable prognosis was associated with early clinical stages (Stages I...... and II) and young age (P stage, age, and mean nuclear...

  7. Stereological analysis of nuclear volume in recurrent meningiomas

    DEFF Research Database (Denmark)

    Madsen, C; Schrøder, H D

    1994-01-01

    A stereological estimation of nuclear volume in recurrent and non-recurrent meningiomas was made. The aim was to investigate whether this method could discriminate between these two groups. We found that the mean nuclear volumes in recurrent meningiomas were all larger at debut than in any...... of the control tumors. The mean nuclear volume of the individual recurrent tumors appeared to change with time, showing a tendency to diminish. A relationship between large nuclear volume at presentation and number of or time interval between recurrences was not found. We conclude that measurement of mean...... nuclear volume in meningiomas might help identify a group at risk of recurrence....

  8. Nondestructive Testing

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Harold [Argonne National Laboratory

    1969-01-01

    A nondestructive test is an examination of an object in any manner which will not impair the future usefulness of the object. This booklet discusses a few basic methods of nondestructive testing, and some of their characteristics. In addition, it discusses possible future methods for nondestructive testing by taking a quick look at some of the methods now under study.

  9. Introduction into integral geometry and stereology

    DEFF Research Database (Denmark)

    Kiderlen, Markus

    Statistics and Random Fields and is a self-containing introduction into integral geometry and its applications in stereology. The most important integral geometric tools for stereological applications are kinematic formulas and results of Blaschke-Petkantschin type. Therefore, Crofton's formula......This text is the extended version of two talks held at the Summer Academy Stochastic Geometry, Spatial Statistics and Random Fields in the Soellerhaus, Germany, in September 2009. It forms (with slight modifications) a chapter of the Springer lecture notes Lectures on Stochastic Geometry, Spatial...

  10. Current automated 3D cell detection methods are not a suitable replacement for manual stereologic cell counting

    Directory of Open Access Journals (Sweden)

    Christoph eSchmitz

    2014-05-01

    Full Text Available Stereologic cell counting has had a major impact on the field of neuroscience. A major bottleneck in stereologic cell counting is that the user must manually decide whether or not each cell is counted according to three-dimensional (3D stereologic counting rules by visual inspection within hundreds of microscopic fields-of-view per investigated brain or brain region. Reliance on visual inspection forces stereologic cell counting to be very labor-intensive and time-consuming, and is the main reason why biased, non-stereologic two-dimensional (2D cell counting approaches have remained in widespread use. We present an evaluation of the performance of modern automated cell detection and segmentation algorithms as a potential alternative to the manual approach in stereologic cell counting. The image data used in this study were 3D microscopic images of thick brain tissue sections prepared with a variety of commonly used nuclear and cytoplasmic stains. The evaluation compared the numbers and locations of cells identified unambiguously and counted exhaustively by an expert observer with those found by three automated 3D cell detection algorithms: nuclei segmentation from the FARSIGHT toolkit, nuclei segmentation by 3D multiple level set methods, and the 3D object counter plug-in for ImageJ. Of these methods, FARSIGHT performed best, with true-positive detection rates between 38–99% and false-positive rates from 3.6–82%. The results demonstrate that the current automated methods suffer from lower detection rates and higher false-positive rates than are acceptable for obtaining valid estimates of cell numbers. Thus, at present, stereologic cell counting with manual decision for object inclusion according to unbiased stereologic counting rules remains the only adequate method for unbiased cell quantification in histologic tissue sections.

  11. Rapid non-destructive quantitative estimation of urania/ thoria in mixed thorium uranium di-oxide pellets by high-resolution gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Shriwastwa, B.B.; Kumar, Anil; Raghunath, B.; Nair, M.R.; Abani, M.C.; Ramachandran, R.; Majumdar, S.; Ghosh, J.K.

    2001-01-01

    A non-destructive technique using high-resolution gamma-ray spectrometry has been standardised for quantitative estimation of uranium/thorium in mixed (ThO 2 -UO 2 ) fuel pellets of varying composition. Four gamma energies were selected; two each from the uranium and thorium series and the time of counting has been optimised. This technique can be used for rapid estimation of U/Th percentage in a large number of mixed fuel pellets from a production campaign

  12. A method for nondestructive estimation of the fracture toughness of CrMoV rotor steels

    International Nuclear Information System (INIS)

    Viswanathan, R.; Gehl, S.

    1990-01-01

    Assessment of the remaining life of steam turbine rotors in the presence of bore defects requires a knowledge of the fracture toughness (K IC ) of the rotors. Current procedures for estimating the K IC involve two steps; as a first step, the fracture appearance transition temperature (FATT) at the critical location is determined; the FATT value is then used to estimate the K IC , based on published correlations between the excess temperature (T-FATT) and K IC . Some problems arise in implementing both of these steps. To determine the FATT of the material, large pieces of material have to be removed, machined into charpy specimens and tested; this procedure is often time consuming and expensive and sometimes not feasible. The excess temperature vs the K IC correlation that is used to derive the K IC values from the FATT data is based on a variety of low alloy steels and is therefore characterized by a large scatter band, thus leading to considerable uncertainty in the estimated K IC . In this work, FATT and K IC data reported for a number of retired CrMoV rotors were gathered and analyzed and correlations specific to CrMoV rotors were developed. Based on these correlations, a method for estimating K IC with greater accuracy, based on a knowledge of the steel chemistry alone, is proposed. The method offers the advantage that very small samples removed from noncritical locations in the rotor would be sufficient to get the desired data

  13. Non-destructive estimates of soil carbonic anhydrase activity and associated soil water oxygen isotope composition

    Science.gov (United States)

    Jones, Sam P.; Ogée, Jérôme; Sauze, Joana; Wohl, Steven; Saavedra, Noelia; Fernández-Prado, Noelia; Maire, Juliette; Launois, Thomas; Bosc, Alexandre; Wingate, Lisa

    2017-12-01

    The contribution of photosynthesis and soil respiration to net land-atmosphere carbon dioxide (CO2) exchange can be estimated based on the differential influence of leaves and soils on budgets of the oxygen isotope composition (δ18O) of atmospheric CO2. To do so, the activity of carbonic anhydrases (CAs), a group of enzymes that catalyse the hydration of CO2 in soils and plants, needs to be understood. Measurements of soil CA activity typically involve the inversion of models describing the δ18O of CO2 fluxes to solve for the apparent, potentially catalysed, rate of CO2 hydration. This requires information about the δ18O of CO2 in isotopic equilibrium with soil water, typically obtained from destructive, depth-resolved sampling and extraction of soil water. In doing so, an assumption is made about the soil water pool that CO2 interacts with, which may bias estimates of CA activity if incorrect. Furthermore, this can represent a significant challenge in data collection given the potential for spatial and temporal variability in the δ18O of soil water and limited a priori information with respect to the appropriate sampling resolution and depth. We investigated whether we could circumvent this requirement by inferring the rate of CO2 hydration and the δ18O of soil water from the relationship between the δ18O of CO2 fluxes and the δ18O of CO2 at the soil surface measured at different ambient CO2 conditions. This approach was tested through laboratory incubations of air-dried soils that were re-wetted with three waters of different δ18O. Gas exchange measurements were made on these soils to estimate the rate of hydration and the δ18O of soil water, followed by soil water extraction to allow for comparison. Estimated rates of CO2 hydration were 6.8-14.6 times greater than the theoretical uncatalysed rate of hydration, indicating that CA were active in these soils. Importantly, these estimates were not significantly different among water treatments, suggesting

  14. Non-destructive equations to estimate the leaf area of Styrax pohlii and Styrax ferrugineus

    Directory of Open Access Journals (Sweden)

    MC Souza

    Full Text Available We developed linear equations to predict the leaf area (LA of the species Styrax pohlii and Styrax ferrugineus using the width (W and length (L leaf dimensions. For both species the linear regression (Y=α+bX using LA as a dependent variable vs. W × L as an independent variable was more efficient than linear regressions using L, W, L2 and W2 as independent variables. Therefore, the LA of S. pohlii can be estimated with the equation LA=0.582+0.683WL, while the LA of S. ferrugineus follows the equation LA=−0.666+0.704WL.

  15. PROBES, POPULATIONS, SAMPLES, MEASUREMENTS AND RELATIONS IN STEREOLOGY

    Directory of Open Access Journals (Sweden)

    Robert T Dehoff

    2011-05-01

    Full Text Available This summary paper provides an overview of the content of stereology. The typical problem at hand centers around some three dimensional object that has an internal structure that determines its function, performance, or response. To understand and quantify the geometry of that structure it is necessary to probe it with geometric entities: points, lines, planes volumes, etc. Meaningful results are obtained only if the set of probes chosen for use in the assessment is drawn uniformly from the population of such probes for the structure as a whole. This requires an understanding of the population of each kind of probe. Interaction of the probes with the structure produce geometric events which are the focus of stereological measurements. In almost all applications the measurement that is made is a simple count of the number of these events. Rigorous application of these requirements for sample design produce unbiased estimates of geometric properties of features in the structure no matter how complex are the features or what their arrangement in space. It is this assumption-free characteristic of the methodology that makes it a powerful tool for characterizing the internal structure of three dimensional objects.

  16. Estimation of cytogenetic risk in the process of non-destructive testing of welds

    Energy Technology Data Exchange (ETDEWEB)

    Fucic, A; Garaj-Vrhovac, V; Kubelka, D [Inst. for Medical Research and Occupational Health, Zagreb (Croatia); Novakovic, M [Ecotec, Zagreb (Croatia)

    1997-12-31

    The estimation of dose based on chromosomal aberration analyzis is a reliable and generally accepted method, and it indicates genome damages earlier than any other method used in medicine. However, according to available literature data it could be seen that in the cases of overexposure of radiographers detected by film dosimeter only skin changes are quite often diagnosed even without heamatological analyzis. Since no biodosimetrical study so far provides data on genome damages of radiographers caused by combined exposure to gamma irradiation and ultrasound the aim of this study was to compare the effects of the exposure to ionizing radiation alone and combined with application of ultrasound during the process of weld testing. It can be concluded that in cases of combined occupational exposure estimation of dose received by radiographers using film dosimetry should be accompanied by cytogenetic monitoring because personal dosimeter for ultrasound has not been constructed yet. In order to minimize health risk biomonitoring can detect possible synergistic action of both ultrasound and ionizing radiation which is not measurable by any physical method. (author).

  17. Reliability of using nondestructive tests to estimate compressive strength of building stones and bricks

    Directory of Open Access Journals (Sweden)

    Ali Abd Elhakam Aliabdo

    2012-09-01

    Full Text Available This study aims to investigate the relationships between Schmidt hardness rebound number (RN and ultrasonic pulse velocity (UPV versus compressive strength (fc of stones and bricks. Four types of rocks (marble, pink lime stone, white lime stone and basalt and two types of burned bricks and lime-sand bricks were studied. Linear and non-linear models were proposed. High correlations were found between RN and UPV versus compressive strength. Validation of proposed models was assessed using other specimens for each material. Linear models for each material showed good correlations than non-linear models. General model between RN and compressive strength of tested stones and bricks showed a high correlation with regression coefficient R2 value of 0.94. Estimation of compressive strength for the studied stones and bricks using their rebound number and ultrasonic pulse velocity in a combined method was generally more reliable than using rebound number or ultrasonic pulse velocity only.

  18. Nondestructive estimation of depth of surface opening cracks in concrete beams

    International Nuclear Information System (INIS)

    Arne, Kevin; In, Chiwon; Kurtis, Kimberly; Kim, Jin-Yeon; Jacobs, Laurence J.

    2014-01-01

    Concrete is one of the most widely used construction materials and thus assessment of damage in concrete structures is of the utmost importance from both a safety point of view and a financial point of view. Of particular interest are surface opening cracks that extend through the concrete cover, as this can expose the steel reinforcement bars underneath and induce corrosion in them. This corrosion can lead to significant subsequent damage in concrete such as cracking and delamination of the cover concrete as well as rust staining on the surface of concrete. Concrete beams are designed and constructed in such a way to provide crack depths up to around 13 cm. Two different types of measurements are made in-situ to estimate depths of real surface cracks (as opposed to saw-cut notches) after unloading: one based on the impact-echo method and the other one based on the diffuse ultrasonic method. These measurements are compared to the crack depth visually observed on the sides of the beams. Discussions are given as to the advantages and disadvantages of each method

  19. An estimation methode for measurement of ultraviolet radiation during nondestructive testing

    Science.gov (United States)

    Hosseinipanah, M.; Movafeghi, A.; Farvadin, D.

    2018-04-01

    Dye penetrant testing and magnetic particle testing are among conventional NDT methods. For increased sensitivity, fluorescence dyes and particles can be used with ultraviolet (black) lights. UV flaw detection lights have different spectra. With the help of photo-filters, the output lights are transferred to UV-A and visible zones. UV-A light can be harmful to human eyes in some conditions. In this research, UV intensity and spectrum were obtained by a Radio-spectrometer for two different UV flaw detector lighting systems. According to the standards such as ASTM E709, UV intensity must be at least 10 W/m2 at a distance of 30 cm. Based on our measurements; these features not achieved in some lamps. On the other hand, intensity and effective intensity of UV lights must be below the some limits for prevention of unprotected eye damage. NDT centers are usually using some type of UV measuring devices. A method for the estimation of effective intensity of UV light has been proposed in this research.

  20. Practical Stereology Applications for the Pathologist.

    Science.gov (United States)

    Brown, Danielle L

    2017-05-01

    Qualitative histopathology is the gold standard for routine examination of morphological tissue changes in the regulatory or academic environment. The human eye is exceptional for pattern recognition but often cannot detect small changes in quantity. In cases where detection of subtle quantitative changes is critical, more sensitive methods are required. Two-dimensional histomorphometry can provide additional quantitative information and is quite useful in many cases. However, the provided data may not be referent to the entire tissue and, as such, it makes several assumptions, which are sources of bias. In contrast, stereology is design based rather than assumption based and uses stringent sampling methods to obtain accurate and precise 3-dimensional information using geometrical and statistical principles. Recent advances in technology have made stereology more approachable and practical for the pathologist in both regulatory and academic environments. This review introduces pathologists to the basic principles of stereology and walks the reader through some real-world examples for the application of these principles in the workplace.

  1. Rapid non-destructive quantitative estimation of urania/ thoria in mixed thorium uranium di-oxide pellets by high-resolution gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shriwastwa, B.B.; Kumar, Anil; Raghunath, B.; Nair, M.R.; Abani, M.C.; Ramachandran, R.; Majumdar, S.; Ghosh, J.K

    2001-06-01

    A non-destructive technique using high-resolution gamma-ray spectrometry has been standardised for quantitative estimation of uranium/thorium in mixed (ThO{sub 2}-UO{sub 2}) fuel pellets of varying composition. Four gamma energies were selected; two each from the uranium and thorium series and the time of counting has been optimised. This technique can be used for rapid estimation of U/Th percentage in a large number of mixed fuel pellets from a production campaign.

  2. STEREOLOGICAL ANALYSIS OF THE COCHLEAR NUCLEI OF MONKEY (MACACA FASCICULARIS AFTER DEAFFERENTATION

    Directory of Open Access Journals (Sweden)

    Ana M Insausti

    2011-05-01

    Full Text Available The cochlear nuclei (CN in the brainstem receive the input signals from the inner ear through the cochlear nerve, and transmit these signals to higher auditory centres. A variety of lesions of the cochlear nerve cause deafness. As reported in the literature, artificial removal of auditive input, or 'deafferentation', induces structural alterations in the CN. The purpose of this study was to estimate a number of relevant stereological parameters of the CN in control and deafferented Macaca fascicularis monkeys.

  3. A new non-destructive method for estimating the remanent life of a turbine rotor steel by reversible magnetic permeability

    International Nuclear Information System (INIS)

    Ryu, K.S.; Nahm, S.H.; Park, J.S.; Yu, K.M.; Kim, Y.B.; Son, D.

    2002-01-01

    We present a new magnetic and non-destructive procedure to evaluate the remanent life of 1Cr-1Mo-0.25V steel using the value of reversible magnetic permeability. The method is based on the existence of reversible magnetic permeability in the differential magnetization around the coercive force. The measurement principle is based on the foundation harmonics voltage induced in a coil using a lock-in amplifier tuned to a frequency of the exciting one. Results obtained for reversible magnetic permeability and Vickers hardness on the aged sample show that the peak interval of reversible magnetic permeability (PIRMP) and Vickers hardness decreases as aging time increases. A softening curve is obtained from the correlation between Vickers hardness and the PIRMP. This curve can be used as a non-destructive method to evaluate the remanent life of 1Cr-1Mo-0.25V steel

  4. Changes in total cell numbers of the basal ganglia in patients with multiple system atrophy - A stereological study

    DEFF Research Database (Denmark)

    Salvesen, Lisette; Ullerup, Birgitte H; Sunay, Fatma B

    2014-01-01

    Total numbers of neurons, oligodendrocytes, astrocytes, and microglia in the basal ganglia and red nucleus were estimated in brains from 11 patients with multiple system atrophy (MSA) and 11 age- and gender-matched control subjects with unbiased stereological methods. Compared to the control...

  5. Rapid, nondestructive estimation of surface polymer layer thickness using attenuated total reflection fourier transform infrared (ATR FT-IR) spectroscopy and synthetic spectra derived from optical principles.

    Science.gov (United States)

    Weinstock, B André; Guiney, Linda M; Loose, Christopher

    2012-11-01

    We have developed a rapid, nondestructive analytical method that estimates the thickness of a surface polymer layer with high precision but unknown accuracy using a single attenuated total reflection Fourier transform infrared (ATR FT-IR) measurement. Because the method is rapid, nondestructive, and requires no sample preparation, it is ideal as a process analytical technique. Prior to implementation, the ATR FT-IR spectrum of the substrate layer pure component and the ATR FT-IR and real refractive index spectra of the surface layer pure component must be known. From these three input spectra a synthetic mid-infrared spectral matrix of surface layers 0 nm to 10,000 nm thick on substrate is created de novo. A minimum statistical distance match between a process sample's ATR FT-IR spectrum and the synthetic spectral matrix provides the thickness of that sample. We show that this method can be used to successfully estimate the thickness of polysulfobetaine surface modification, a hydrated polymeric surface layer covalently bonded onto a polyetherurethane substrate. A database of 1850 sample spectra was examined. Spectrochemical matrix-effect unknowns, such as the nonuniform and molecularly novel polysulfobetaine-polyetherurethane interface, were found to be minimal. A partial least squares regression analysis of the database spectra versus their thicknesses as calculated by the method described yielded an estimate of precision of ±52 nm.

  6. Stereology as a tool to assess reproduction strategy and fecundity of teleost fishes

    DEFF Research Database (Denmark)

    Bucholtz, Rikke Hagstrøm

    methods to assess fecundity and reproductive strategies. The strength of the stereological method being that, in combination with conventional histological analysis, quantification of all oocyte categories is possible, as well as registration of qualitative characteristics relating to spawning history...... of oocyte dynamics in fish and were successfully implemented in herring ovaries for quantification of both oocyte numbers and sizes as well as total volume fraction of atretic oocytes, introducing a negligible error to the total variance of estimates. The histological nature of the stereological methods...... facilitated a ready validation of maturity data, distinguishing first time spawners from repeat spawners, as well as a ready recognition of ongoing oocyte recruitment in early maturity stages, early stage atresia, POFs and residual eggs. Analyzing a sample of females all collected during a short time frame...

  7. Practical application of stereological methods in experimental kidney animal models.

    Science.gov (United States)

    Fernández García, María Teresa; Núñez Martínez, Paula; García de la Fuente, Vanessa; Sánchez Pitiot, Marta; Muñiz Salgueiro, María Del Carmen; Perillán Méndez, Carmen; Argüelles Luis, Juan; Astudillo González, Aurora

    The kidneys are vital organs responsible for excretion, fluid and electrolyte balance and hormone production. The nephrons are the kidney's functional and structural units. The number, size and distribution of the nephron components contain relevant information on renal function. Stereology is a branch of morphometry that applies mathematical principles to obtain three-dimensional information from serial, parallel and equidistant two-dimensional microscopic sections. Because of the complexity of stereological studies and the lack of scientific literature on the subject, the aim of this paper is to clearly explain, through animal models, the basic concepts of stereology and how to calculate the main kidney stereological parameters that can be applied in future experimental studies. Copyright © 2016 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  8. STEREOLOGY FROM ONE OF ALL THE POSSIBLE ANGLES

    Directory of Open Access Journals (Sweden)

    Leszek Wojnar

    2011-05-01

    Full Text Available Relation between image analysis and stereology is discussed in terms of different fields of applications, especially materials science, biology and medicine. Some long-term tendencies observed as well as possible future trends are discussed. The need of a wider use of image analysis techniques including ma1hematical morphology in any field of science is demons1rated. Simultaneously, the significance of stereological background in automatic quantification of1he investigated structures is confirmed.

  9. Quantitative analysis of the renal aging in rats. Stereological study

    OpenAIRE

    Melchioretto, Eduardo Felippe; Zeni, Marcelo; Veronez, Djanira Aparecida da Luz; Martins Filho, Eduardo Lopes; Fraga, Rogério de

    2016-01-01

    ABSTRACT PURPOSE: To evaluate the renal function and the renal histological alterations through the stereology and morphometrics in rats submitted to the natural process of aging. METHODS: Seventy two Wistar rats, divided in six groups. Each group was sacrificed in a different age: 3, 6, 9, 12, 18 and 24 months. It was performed right nephrectomy, stereological and morphometric analysis of the renal tissue (renal volume and weight, density of volume (Vv[glom]) and numerical density (Nv[glo...

  10. [Simulation and data analysis of stereological modeling based on virtual slices].

    Science.gov (United States)

    Wang, Hao; Shen, Hong; Bai, Xiao-yan

    2008-05-01

    To establish a computer-assisted stereological model for simulating the process of slice section and evaluate the relationship between section surface and estimated three-dimensional structure. The model was designed by mathematic method as a win32 software based on the MFC using Microsoft visual studio as IDE for simulating the infinite process of sections and analysis of the data derived from the model. The linearity of the fitting of the model was evaluated by comparison with the traditional formula. The win32 software based on this algorithm allowed random sectioning of the particles distributed randomly in an ideal virtual cube. The stereological parameters showed very high throughput (>94.5% and 92%) in homogeneity and independence tests. The data of density, shape and size of the section were tested to conform to normal distribution. The output of the model and that from the image analysis system showed statistical correlation and consistency. The algorithm we described can be used for evaluating the stereologic parameters of the structure of tissue slices.

  11. A handheld support system to facilitate stereological measurements and mapping of branching structures

    DEFF Research Database (Denmark)

    Gardi, J.E.; Wulfsohn, Dvora-Laiô; Nyengaard, J.R.

    2007-01-01

    specifications, software and Graphical User Interface (GUI) development, functionality and application of the handheld system using four examples: (1) sampling monkey lung bronchioles for estimation of diameter and wall thickness (2) sampling rat kidney for estimating number of arteries and arterioles......‘BranchSampler' is a system for computer-assisted manual stereology written for handheld devices running Windows CE. The system has been designed specifically to streamline data collection and optimize sampling of tree-like branching structures, with particular aims of reducing user errors, saving...

  12. Stereological measures of trabecular bone structure: comparison of 3D micro computed tomography with 2D histological sections in human proximal tibial bone biopsies

    DEFF Research Database (Denmark)

    Thomsen, Jesper Skovhus; Laib, A.; Koller, B.

    2005-01-01

    Stereology applied on histological sections is the 'gold standard' for obtaining quantitative information on cancellous bone structure. Recent advances in micro computed tomography (microCT) have made it possible to acquire three-dimensional (3D) data non-destructively. However, before the 3D...... methods can be used as a substitute for the current 'gold standard' they have to be verified against the existing standard. The aim of this study was to compare bone structural measures obtained from 3D microCT data sets with those obtained by stereology performed on conventional histological sections...... tibial metaphysis. The biopsies were embedded in methylmetacrylate before microCT scanning in a Scanco microCT 40 scanner at a resolution of 20 x 20 x 20 microm3, and the 3D data sets were analysed with a computer program. After microCT scanning, 16 sections were cut from the central 2 mm of each biopsy...

  13. Histological versus stereological methods applied at spermatogonia during normal human development

    DEFF Research Database (Denmark)

    Cortes, D

    1990-01-01

    The number of spermatogonia per tubular transverse section (S/T), and the percentage of seminiferous tubulus containing spermatogonia (the fertility index (FI] were measured in 40 pairs of normal autopsy testes aged 28 weeks of gestation-40 years. S/T and FI showed similar changes during the whole...... period, and were minimal between 1 and 4 years. The number of spermatogonia per testis (S/testis) and the number of spermatogonia per cm3 testis tissue (S/cm3) were estimated by stereological methods in the same testes. S/T and FI respectively were significantly correlated both to S/testis and S/cm3. So...

  14. An approach for the fatigue estimation of porous cast iron based on non-destructive testing results

    Directory of Open Access Journals (Sweden)

    Heinrietz André

    2014-06-01

    Full Text Available Big cast iron components made of spheroidal cast iron allow constructing big structures such as stone mills, engine blocks or wind mills with acceptable expenses. Thus, in economically optimized cast processes pores cannot be always prevented in thick walled cast iron components and these components are often rejected because of safety reasons. On the one hand the fatigue performance of high loadable spheroidal cast iron components is reduced significantly by the presence of local porosities which has been pointed out in the past. On the other hand concepts for the fatigue estimation based on fracture mechanics which take the size and localization of the defect into account can lead to erroneous estimations because the defect is modelled as a crack. The challenge of an estimation method is to derive a fatigue life without the necessity to perform component tests. In the contribution an estimation method is presented which is able to determine the fatigue strength of a material volume taking the pores into account. The method can be applied based on data from computer tomographic X-ray (CT or Sampling Phased Array (SPA ultrasonic analyses. The method is presented for three spheroidal cast iron types: ferritic GJS-400-18, ferritic GJS-450-15 with high silicon content and perlitic GJS-700-3.

  15. Confocal stereology: an efficient tool for measurement of microscopic structures

    Czech Academy of Sciences Publication Activity Database

    Kubínová, Lucie; Janáček, Jiří

    2015-01-01

    Roč. 360, č. 1 (2015), s. 13-28 ISSN 0302-766X R&D Projects: GA MŠk(CZ) LH13028 Institutional support: RVO:67985823 Keywords : 3-D images * confocal microscopy * geometrical characteristics * spatial probes * stereology Subject RIV: EA - Cell Biology Impact factor: 2.948, year: 2015

  16. Stereological study of postnatal development in the mouse utricular macula

    DEFF Research Database (Denmark)

    Kirkegaard, Mette; Nyengaard, Jens Randel

    2005-01-01

    This study describes the morphometric changes taking place in the utricular macula of mice with ages in geometric progression from 1 to 512 days after birth. By using design-based stereological methods, the total volume and surface area of the sensory epithelium as well the total number of the ha...

  17. Comparison of automated brain volumetry methods with stereology in children aged 2 to 3 years

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, Kristina N. [University Children' s Hospital of Zurich, Center for MR Research, Zurich (Switzerland); University Children' s Hospital, Pediatric Cardiology, Zurich (Switzerland); Latal, Beatrice [University Children' s Hospital, Child Development Center, Zurich (Switzerland); University Children' s Hospital, Children' s Research Center, Zurich (Switzerland); Knirsch, Walter [University Children' s Hospital, Pediatric Cardiology, Zurich (Switzerland); University Children' s Hospital, Children' s Research Center, Zurich (Switzerland); Scheer, Ianina [University Children' s Hospital, Department for Diagnostic Neuroradiology, Zurich (Switzerland); Rhein, Michael von [University Children' s Hospital, Child Development Center, Zurich (Switzerland); Reich, Bettina; Bauer, Juergen; Gummel, Kerstin [Justus-Liebig University, Pediatric Heart Center, University Hospital Giessen, Giessen (Germany); Roberts, Neil [University of Edinburgh, Clinical Research and Imaging Centre (CRIC), The Queens Medical Research Institute (QMRI), Edinburgh (United Kingdom); O' Gorman Tuura, Ruth [University Children' s Hospital of Zurich, Center for MR Research, Zurich (Switzerland); University Children' s Hospital, Children' s Research Center, Zurich (Switzerland)

    2016-09-15

    The accurate and precise measurement of brain volumes in young children is important for early identification of children with reduced brain volumes and an increased risk for neurodevelopmental impairment. Brain volumes can be measured from cerebral MRI (cMRI), but most neuroimaging tools used for cerebral segmentation and volumetry were developed for use in adults and have not been validated in infants or young children. Here, we investigate the feasibility and accuracy of three automated software methods (i.e., SPM, FSL, and FreeSurfer) for brain volumetry in young children and compare the measures with corresponding volumes obtained using the Cavalieri method of modern design stereology. Cerebral MRI data were collected from 21 children with a complex congenital heart disease (CHD) before Fontan procedure, at a median age of 27 months (range 20.9-42.4 months). Data were segmented with SPM, FSL, and FreeSurfer, and total intracranial volume (ICV) and total brain volume (TBV) were compared with corresponding measures obtained using the Cavalieri method. Agreement between the estimated brain volumes (ICV and TBV) relative to the gold standard stereological volumes was strongest for FreeSurfer (p < 0.001) and moderate for SPM segment (ICV p = 0.05; TBV p = 0.006). No significant association was evident between ICV and TBV obtained using SPM NewSegment and FSL FAST and the corresponding stereological volumes. FreeSurfer provides an accurate method for measuring brain volumes in young children, even in the presence of structural brain abnormalities. (orig.)

  18. Comparison of automated brain volumetry methods with stereology in children aged 2 to 3 years

    International Nuclear Information System (INIS)

    Mayer, Kristina N.; Latal, Beatrice; Knirsch, Walter; Scheer, Ianina; Rhein, Michael von; Reich, Bettina; Bauer, Juergen; Gummel, Kerstin; Roberts, Neil; O'Gorman Tuura, Ruth

    2016-01-01

    The accurate and precise measurement of brain volumes in young children is important for early identification of children with reduced brain volumes and an increased risk for neurodevelopmental impairment. Brain volumes can be measured from cerebral MRI (cMRI), but most neuroimaging tools used for cerebral segmentation and volumetry were developed for use in adults and have not been validated in infants or young children. Here, we investigate the feasibility and accuracy of three automated software methods (i.e., SPM, FSL, and FreeSurfer) for brain volumetry in young children and compare the measures with corresponding volumes obtained using the Cavalieri method of modern design stereology. Cerebral MRI data were collected from 21 children with a complex congenital heart disease (CHD) before Fontan procedure, at a median age of 27 months (range 20.9-42.4 months). Data were segmented with SPM, FSL, and FreeSurfer, and total intracranial volume (ICV) and total brain volume (TBV) were compared with corresponding measures obtained using the Cavalieri method. Agreement between the estimated brain volumes (ICV and TBV) relative to the gold standard stereological volumes was strongest for FreeSurfer (p < 0.001) and moderate for SPM segment (ICV p = 0.05; TBV p = 0.006). No significant association was evident between ICV and TBV obtained using SPM NewSegment and FSL FAST and the corresponding stereological volumes. FreeSurfer provides an accurate method for measuring brain volumes in young children, even in the presence of structural brain abnormalities. (orig.)

  19. Morphometric changes in the spinal cord during prenatal life: a stereological study in sheep.

    Science.gov (United States)

    Sadeghinezhad, Javad; Zadsar, Narges; Hasanzadeh, Beal

    2018-03-01

    This study describes the volumetric changes in the spinal cord during prenatal life in sheep using quantitative stereological methods. Twenty healthy sheep fetuses were included in the present study, divided into four groups representing 9-11, 12-14, 15-17, and 18-20 weeks of gestation. In each group, the spinal cord was dissected out and sampled according to the unbiased systematic random sampling method then used for stereological estimations. The total volume of spinal cord, volume of gray matter (GM), volume of white matter (WM), ratio of GM volume to WM volume, and volume of central canal (CC) were estimated in the whole spinal cord and its various regions using Cavalieri's principle. The total volume of the spinal cord increased 8 times from week 9 to week 20. The cervical region showed the greatest (9.7 times) and the sacral region the least (6.3 times) volumetric change. The CC volume of the whole spinal cord increased 5.8 times from week 9 to week 20. The cervical region developed faster (8.2 times) and the thoracic region slower (4.4 times) than the total spinal cord. During development, the volume ratio of GM to WM decreased from lower toward upper regions. The greatest volume changes occurred mostly in weeks 9-11 and 12-14. The cervical region showed the greatest volume changes in comparison with other regions of the spinal cord.

  20. Prediction of prognosis in patients with epidural hematoma by a new stereological method

    International Nuclear Information System (INIS)

    Kalkan, E.; Cander, B.; Gul, M.; Girisgin, S.; Karabagli, H.; Sahin, B.

    2007-01-01

    Epidural hematoma (EH) is a serious clinical event observed in 2% of head trauma patients. Studies regarding the effects of epidural hematoma volume (EHV) on prognosis are not sufficient. In this study, we applied the volume fraction approach of the stereological method to estimate the hematoma to brain volume fraction (HBVF), and investigated the relation between the HBVF and prognosis. Fifty-nine EH patients (46 male and 13 female subjects, with average age of 21 years) admitted to the emergency clinic were included. The HBVF was estimated on the printed films of cranial computed tomography scans. For this purpose, common point counting grids were superimposed over the scan frames. According to the clinical results, patients were divided into three groups as complete recovery (43), disability (8) and exitus (8). The HBVF was compared with the clinical results. HBVF was determined as 4.6% in the patients with recovery, 8.1% in disability, and 7.6% in exitus patients. The HBVF values were lowest in recovery patients, and the difference between the recovery and the other two groups was statistically significant (p=0.007). However, there was no statistically significant difference in HBVF between disability and exitus patients (p>0.05). In conclusion, the HBVF can be an important tool to determine prognosis, and it can be measured using the volume fraction approach of stereological methods as developed in the present study. (author)

  1. A comparison of porosity analysis using 2D stereology estimates and 3D serial sectioning for additively manufactured Ti 6Al 2Sn 4Zr 2Mo alloy; Vergleich der Porositaetsanalyse einer Ti 6Al 2Sn 4Zr 2Mo-Legierung aus additiver Fertigung mittels stereologischer Schaetzungen (2D) und mit Serienschnitten (3D)

    Energy Technology Data Exchange (ETDEWEB)

    Ganti, Satya R.; Velez, Michael A.; Geier, Brian A.; Hayes, Brian J.; Turner, Bryan J.; Jenkins, Elizabeth J. [UES Inc., Dayton, OH (United States)

    2017-02-15

    Porosity is a typical defect in additively manufactured (AM) parts. Such defects limit the properties and performance of AM parts, and therefore need to be characterized accurately. Current methods for characterization of defects and microstructure rely on classical stereological methods that extrapolate information from two dimensional images. The automation of serial sectioning provides an opportunity to precisely and accurately quantify porosity in three dimensions in materials. In this work, we analyzed the porosity of an additively manufactured Ti 6Al 2Sn 4Zr 2Mo sample using Robo-Met.3D {sup registered}, an automated serial sectioning system. Image processing for three dimensional reconstruction of the serial-sectioned two dimensional images was performed using open source image analysis software (Fiji/ImageJ, Dream.3D, Paraview). The results from this 3D serial sectioning analysis were then compared to classical 2D stereological methods (Saltykov stereological theory). We found that for this dataset, the classical 2D methods underestimated the porosity size and distributions of the larger pores; a critical attribute to fatigue behavior of the AM part. The results suggest that acquiring experimental data with equipment such as Robo-Met.3D {sup registered} to measure the number and size of particles such as pores in a volume irrespective of knowing their shape is a better choice.

  2. Computer-assisted stereology and automated image analysis for quantification of tumor infiltrating lymphocytes in colon cancer.

    Science.gov (United States)

    Eriksen, Ann C; Andersen, Johnnie B; Kristensson, Martin; dePont Christensen, René; Hansen, Torben F; Kjær-Frifeldt, Sanne; Sørensen, Flemming B

    2017-08-29

    Precise prognostic and predictive variables allowing improved post-operative treatment stratification are missing in patients treated for stage II colon cancer (CC). Investigation of tumor infiltrating lymphocytes (TILs) may be rewarding, but the lack of a standardized analytic technique is a major concern. Manual stereological counting is considered the gold standard, but digital pathology with image analysis is preferred due to time efficiency. The purpose of this study was to compare manual stereological estimates of TILs with automatic counts obtained by image analysis, and at the same time investigate the heterogeneity of TILs. From 43 patients treated for stage II CC in 2002 three paraffin embedded, tumor containing tissue blocks were selected one of them representing the deepest invasive tumor front. Serial sections from each of the 129 blocks were immunohistochemically stained for CD3 and CD8, and the slides were scanned. Stereological estimates of the numerical density and area fraction of TILs were obtained using the computer-assisted newCAST stereology system. For the image analysis approach an app-based algorithm was developed using Visiopharm Integrator System software. For both methods the tumor areas of interest (invasive front and central area) were manually delineated by the observer. Based on all sections, the Spearman's correlation coefficients for density estimates varied from 0.9457 to 0.9638 (p heterogeneity, intra-class correlation coefficients (ICC) for CD3+ TILs varied from 0.615 to 0.746 in the central area, and from 0.686 to 0.746 in the invasive area. ICC for CD8+ TILs varied from 0.724 to 0.775 in the central area, and from 0.746 to 0.765 in the invasive area. Exact objective and time efficient estimates of numerical densities and area fractions of CD3+ and CD8+ TILs in stage II colon cancer can be obtained by image analysis and are highly correlated to the corresponding estimates obtained by the gold standard based on stereology

  3. Developing in situ non-destructive estimates of crop biomass to address issues of scale in remote sensing

    Science.gov (United States)

    Marshall, Michael T.; Thenkabail, Prasad S.

    2015-01-01

    Ground-based estimates of aboveground wet (fresh) biomass (AWB) are an important input for crop growth models. In this study, we developed empirical equations of AWB for rice, maize, cotton, and alfalfa, by combining several in situ non-spectral and spectral predictors. The non-spectral predictors included: crop height (H), fraction of absorbed photosynthetically active radiation (FAPAR), leaf area index (LAI), and fraction of vegetation cover (FVC). The spectral predictors included 196 hyperspectral narrowbands (HNBs) from 350 to 2500 nm. The models for rice, maize, cotton, and alfalfa included H and HNBs in the near infrared (NIR); H, FAPAR, and HNBs in the NIR; H and HNBs in the visible and NIR; and FVC and HNBs in the visible; respectively. In each case, the non-spectral predictors were the most important, while the HNBs explained additional and statistically significant predictors, but with lower variance. The final models selected for validation yielded an R2 of 0.84, 0.59, 0.91, and 0.86 for rice, maize, cotton, and alfalfa, which when compared to models using HNBs alone from a previous study using the same spectral data, explained an additional 12%, 29%, 14%, and 6% in AWB variance. These integrated models will be used in an up-coming study to extrapolate AWB over 60 × 60 m transects to evaluate spaceborne multispectral broad bands and hyperspectral narrowbands.

  4. Developing in situ Non-Destructive Estimates of Crop Biomass to Address Issues of Scale in Remote Sensing

    Directory of Open Access Journals (Sweden)

    Michael Marshall

    2015-01-01

    Full Text Available Ground-based estimates of aboveground wet (fresh biomass (AWB are an important input for crop growth models. In this study, we developed empirical equations of AWB for rice, maize, cotton, and alfalfa, by combining several in situ non-spectral and spectral predictors. The non-spectral predictors included: crop height (H, fraction of absorbed photosynthetically active radiation (FAPAR, leaf area index (LAI, and fraction of vegetation cover (FVC. The spectral predictors included 196 hyperspectral narrowbands (HNBs from 350 to 2500 nm. The models for rice, maize, cotton, and alfalfa included H and HNBs in the near infrared (NIR; H, FAPAR, and HNBs in the NIR; H and HNBs in the visible and NIR; and FVC and HNBs in the visible; respectively. In each case, the non-spectral predictors were the most important, while the HNBs explained additional and statistically significant predictors, but with lower variance. The final models selected for validation yielded an R2 of 0.84, 0.59, 0.91, and 0.86 for rice, maize, cotton, and alfalfa, which when compared to models using HNBs alone from a previous study using the same spectral data, explained an additional 12%, 29%, 14%, and 6% in AWB variance. These integrated models will be used in an up-coming study to extrapolate AWB over 60 × 60 m transects to evaluate spaceborne multispectral broad bands and hyperspectral narrowbands.

  5. Variance estimation for generalized Cavalieri estimators

    OpenAIRE

    Johanna Ziegel; Eva B. Vedel Jensen; Karl-Anton Dorph-Petersen

    2011-01-01

    The precision of stereological estimators based on systematic sampling is of great practical importance. This paper presents methods of data-based variance estimation for generalized Cavalieri estimators where errors in sampling positions may occur. Variance estimators are derived under perturbed systematic sampling, systematic sampling with cumulative errors and systematic sampling with random dropouts. Copyright 2011, Oxford University Press.

  6. Stereological estimates of nuclear volume in thin malignant melanomas

    DEFF Research Database (Denmark)

    Björnhagen, V; Månsson-Brahme, E; Lindholm, J

    1998-01-01

    melanomas were individually compared with 33 thin non-metastasizing melanomas after individual matching of cases with one or two randomly chosen controls for site of primary tumour, tumour thickness, level of invasion, tumour regression and follow-up. Conditional logistic regression analysis showed...

  7. Non-destructive Engineering

    International Nuclear Information System (INIS)

    Ko, Jin Hyeon; Ryu, Taek In; Ko, Jun Bin; Hwang, Yong Hwa

    2006-08-01

    This book gives descriptions of non-destructive engineering on outline of non-destructive test, weld defects, radiographic inspection radiography, ultrasonic inspection, magnetic particle testing, liquid penetrant testing, eddy current inspection method, strain measurement, acoustic emission inspection method, other non-destructive testing like leakage inspection method, and non-destructive mechanics for fault analysis such as Griffiths creaking theory, and stress analysis of creaking.

  8. Stereological analysis of neuron, glial and endothelial cell numbers in the human amygdaloid complex.

    Directory of Open Access Journals (Sweden)

    María García-Amado

    Full Text Available Cell number alterations in the amygdaloid complex (AC might coincide with neurological and psychiatric pathologies with anxiety imbalances as well as with changes in brain functionality during aging. This stereological study focused on estimating, in samples from 7 control individuals aged 20 to 75 years old, the number and density of neurons, glia and endothelial cells in the entire AC and in its 5 nuclear groups (including the basolateral (BL, corticomedial and central groups, 5 nuclei and 13 nuclear subdivisions. The volume and total cell number in these territories were determined on Nissl-stained sections with the Cavalieri principle and the optical fractionator. The AC mean volume was 956 mm(3 and mean cell numbers (x10(6 were: 15.3 neurons, 60 glial cells and 16.8 endothelial cells. The numbers of endothelial cells and neurons were similar in each AC region and were one fourth the number of glial cells. Analysis of the influence of the individuals' age at death on volume, cell number and density in each of these 24 AC regions suggested that aging does not affect regional size or the amount of glial cells, but that neuron and endothelial cell numbers respectively tended to decrease and increase in territories such as AC or BL. These accurate stereological measures of volume and total cell numbers and densities in the AC of control individuals could serve as appropriate reference values to evaluate subtle alterations in this structure in pathological conditions.

  9. Stereological analysis of neuron, glial and endothelial cell numbers in the human amygdaloid complex.

    Science.gov (United States)

    García-Amado, María; Prensa, Lucía

    2012-01-01

    Cell number alterations in the amygdaloid complex (AC) might coincide with neurological and psychiatric pathologies with anxiety imbalances as well as with changes in brain functionality during aging. This stereological study focused on estimating, in samples from 7 control individuals aged 20 to 75 years old, the number and density of neurons, glia and endothelial cells in the entire AC and in its 5 nuclear groups (including the basolateral (BL), corticomedial and central groups), 5 nuclei and 13 nuclear subdivisions. The volume and total cell number in these territories were determined on Nissl-stained sections with the Cavalieri principle and the optical fractionator. The AC mean volume was 956 mm(3) and mean cell numbers (x10(6)) were: 15.3 neurons, 60 glial cells and 16.8 endothelial cells. The numbers of endothelial cells and neurons were similar in each AC region and were one fourth the number of glial cells. Analysis of the influence of the individuals' age at death on volume, cell number and density in each of these 24 AC regions suggested that aging does not affect regional size or the amount of glial cells, but that neuron and endothelial cell numbers respectively tended to decrease and increase in territories such as AC or BL. These accurate stereological measures of volume and total cell numbers and densities in the AC of control individuals could serve as appropriate reference values to evaluate subtle alterations in this structure in pathological conditions.

  10. First and second order stereology of hyaline cartilage: Application on mice femoral cartilage.

    Science.gov (United States)

    Noorafshan, Ali; Niazi, Behnam; Mohamadpour, Masoomeh; Hoseini, Leila; Hoseini, Najmeh; Owji, Ali Akbar; Rafati, Ali; Sadeghi, Yasaman; Karbalay-Doust, Saied

    2016-11-01

    Stereological techniques could be considered in research on cartilage to obtain quantitative data. The present study aimed to explain application of the first- and second-order stereological methods on articular cartilage of mice and the methods applied on the mice exposed to cadmium (Cd). The distal femoral articular cartilage of BALB/c mice (control and Cd-treated) was removed. Then, volume and surface area of the cartilage and number of chondrocytes were estimated using Cavalieri and optical dissector techniques on isotropic uniform random sections. Pair-correlation function [g(r)] and cross-correlation function were calculated to express the spatial arrangement of chondrocytes-chondrocytes and chondrocytes-matrix (chondrocyte clustering/dispersing), respectively. The mean±standard deviation of the cartilage volume, surface area, and thickness were 1.4±0.1mm 3 , 26.2±5.4mm 2 , and 52.8±6.7μm, respectively. Besides, the mean number of chondrocytes was 680±200 (×10 3 ). The cartilage volume, cartilage surface area, and number of chondrocytes were respectively reduced by 25%, 27%, and 27% in the Cd-treated mice in comparison to the control animals (pcartilage components carried potential advantages for investigating the cartilage in different joint conditions. Chondrocyte clustering/dispersing and cellularity can be evaluated in cartilage assessment in normal or abnormal situations. Copyright © 2016 Elsevier GmbH. All rights reserved.

  11. Unbiased stereologic techniques for practical use in diagnostic histopathology

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt

    1995-01-01

    Grading of malignancy by the examination of morphologic and cytologic details in histologic sections from malignant neoplasms is based exclusively on qualitative features, associated with significant subjectivity, and thus rather poor reproducibility. The traditional way of malignancy grading may...... by introducing quantitative techniques in the histopathologic discipline of malignancy grading. Unbiased stereologic methods, especially based on measurements of nuclear three-dimensional mean size, have during the last decade proved their value in this regard. In this survey, the methods are reviewed regarding...... the basic technique involved, sampling, efficiency, and reproducibility. Various types of cancers, where stereologic grading of malignancy has been used, are reviewed and discussed with regard to the development of a new objective and reproducible basis for carrying out prognosis-related malignancy grading...

  12. Unbiased stereologic techniques for practical use in diagnostic histopathology

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt

    1995-01-01

    by introducing quantitative techniques in the histopathologic discipline of malignancy grading. Unbiased stereologic methods, especially based on measurements of nuclear three-dimensional mean size, have during the last decade proved their value in this regard. In this survey, the methods are reviewed regarding......Grading of malignancy by the examination of morphologic and cytologic details in histologic sections from malignant neoplasms is based exclusively on qualitative features, associated with significant subjectivity, and thus rather poor reproducibility. The traditional way of malignancy grading may...... of solid tumors. This new, unbiased attitude to malignancy grading is associated with excellent virtues, which ultimately may help the clinician in the choice of optimal treatment of the individual patient suffering from cancer. Stereologic methods are not solely applicable to the field of malignancy...

  13. Stereological quantification of mast cells in human synovium

    DEFF Research Database (Denmark)

    Damsgaard, T E; Sørensen, Flemming Brandt; Herlin, T

    1999-01-01

    Mast cells participate in both the acute allergic reaction as well as in chronic inflammatory diseases. Earlier studies have revealed divergent results regarding the quantification of mast cells in the human synovium. The aim of the present study was therefore to quantify these cells in the human...... synovium, using stereological techniques. Different methods of staining and quantification have previously been used for mast cell quantification in human synovium. Stereological techniques provide precise and unbiased information on the number of cell profiles in two-dimensional tissue sections of......, in this case, human synovium. In 10 patients suffering from osteoarthritis a median of 3.6 mast cells/mm2 synovial membrane was found. The total number of cells (synoviocytes, fibroblasts, lymphocytes, leukocytes) present was 395.9 cells/mm2 (median). The mast cells constituted 0.8% of all the cell profiles...

  14. STEREOLOGICAL QUANTITATION OF LEYDIG AND SERTOLI CELLS IN THE TESTIS FROM YOUNG AND OLD MEN

    Directory of Open Access Journals (Sweden)

    Peter M Petersen

    2011-05-01

    Full Text Available One of the newer stereological methods, the optical fractionator, was applied to the study of the effects of ageing on the human testis. The estimated total number of Sertoli and Leydig cells per testis in men younger than 30 years were 430×106 (CV = SD/mean = 0.35 and 117×106 (CV = 0.53, respectively, while in men older than 50 years the estimated total Sertoli cell number was 266×106 (CV = 0.46 and the mean Leydig cell number 83×106 (CV = 0.53. The difference between the number of Sertoli cells in men younger than 30 years compared with men older than 50 years was close to statistical significance (p = 0.052 while no differences was found in total Leydig cell number (p = 0.22.

  15. Quantitative analysis of the renal aging in rats. Stereological study.

    Science.gov (United States)

    Melchioretto, Eduardo Felippe; Zeni, Marcelo; Veronez, Djanira Aparecida da Luz; Martins, Eduardo Lopes; Fraga, Rogério de

    2016-05-01

    To evaluate the renal function and the renal histological alterations through the stereology and morphometrics in rats submitted to the natural process of aging. Seventy two Wistar rats, divided in six groups. Each group was sacrificed in a different age: 3, 6, 9, 12, 18 and 24 months. It was performed right nephrectomy, stereological and morphometric analysis of the renal tissue (renal volume and weight, density of volume (Vv[glom]) and numerical density (Nv[glom]) of the renal glomeruli and average glomerular volume (Vol[glom])) and also it was evaluated the renal function for the dosage of serum creatinine and urea. There was significant decrease of the renal function in the oldest rats. The renal volume presented gradual increase during the development of the rats with the biggest values registered in the group of animals at 12 months of age and significant progressive decrease in older animals. Vv[glom] presented statistically significant gradual reduction between the groups and the Nv[glom] also decreased significantly. The renal function proved to be inferior in senile rats when compared to the young rats. The morphometric and stereological analysis evidenced renal atrophy, gradual reduction of the volume density and numerical density of the renal glomeruli associated to the aging process.

  16. Light scattering in porous materials: Geometrical optics and stereological approach

    International Nuclear Information System (INIS)

    Malinka, Aleksey V.

    2014-01-01

    Porous material has been considered from the point of view of stereology (geometrical statistics), as a two-phase random mixture of solid material and air. Considered are the materials having the refractive index with the real part that differs notably from unit and the imaginary part much less than unit. Light scattering in such materials has been described using geometrical optics. These two – the geometrical optics laws and the stereological approach – allow one to obtain the inherent optical properties of such a porous material, which are basic in the radiative transfer theory: the photon survival probability, the scattering phase function, and the polarization properties (Mueller matrix). In this work these characteristics are expressed through the refractive index of the material and the random chord length distribution. The obtained results are compared with the traditional approach, modeling the porous material as a pack of particles of different shapes. - Highlights: • Porous material has been considered from the point of view of stereology. • Properties of a two-phase random mixture of solid material and air are considered. • Light scattering in such materials has been described using geometrical optics. • The inherent optical properties of such a porous material have been obtained

  17. Digital immunohistochemistry wizard: image analysis-assisted stereology tool to produce reference data set for calibration and quality control.

    Science.gov (United States)

    Plancoulaine, Benoît; Laurinaviciene, Aida; Meskauskas, Raimundas; Baltrusaityte, Indra; Besusparis, Justinas; Herlin, Paulette; Laurinavicius, Arvydas

    2014-01-01

    Digital image analysis (DIA) enables better reproducibility of immunohistochemistry (IHC) studies. Nevertheless, accuracy of the DIA methods needs to be ensured, demanding production of reference data sets. We have reported on methodology to calibrate DIA for Ki67 IHC in breast cancer tissue based on reference data obtained by stereology grid count. To produce the reference data more efficiently, we propose digital IHC wizard generating initial cell marks to be verified by experts. Digital images of proliferation marker Ki67 IHC from 158 patients (one tissue microarray spot per patient) with an invasive ductal carcinoma of the breast were used. Manual data (mD) were obtained by marking Ki67-positive and negative tumour cells, using a stereological method for 2D object enumeration. DIA was used as an initial step in stereology grid count to generate the digital data (dD) marks by Aperio Genie and Nuclear algorithms. The dD were collected into XML files from the DIA markup images and overlaid on the original spots along with the stereology grid. The expert correction of the dD marks resulted in corrected data (cD). The percentages of Ki67 positive tumour cells per spot in the mD, dD, and cD sets were compared by single linear regression analysis. Efficiency of cD production was estimated based on manual editing effort. The percentage of Ki67-positive tumor cells was in very good agreement in the mD, dD, and cD sets: regression of cD from dD (R2=0.92) reflects the impact of the expert editing the dD as well as accuracy of the DIA used; regression of the cD from the mD (R2=0.94) represents the consistency of the DIA-assisted ground truth (cD) with the manual procedure. Nevertheless, the accuracy of detection of individual tumour cells was much lower: in average, 18 and 219 marks per spot were edited due to the Genie and Nuclear algorithm errors, respectively. The DIA-assisted cD production in our experiment saved approximately 2/3 of manual marking. Digital IHC wizard

  18. Handbook of nondestructive evaluation

    National Research Council Canada - National Science Library

    Hellier, Charles

    2013-01-01

    "Fully revised to cover the latest nondestructive testing (NDT) procedures, this practical resource reviews established and emerging methods for examining materials without destroying them or altering their structure...

  19. Stereological brain volume changes in post-weaned socially isolated rats

    DEFF Research Database (Denmark)

    Fabricius, Katrine; Helboe, Lone; Steiniger-Brach, Björn

    2010-01-01

    Lister Hooded rats isolated from postnatal day 25 for 15 weeks. We observed the expected gender differences in total brain volume with males having larger brains than females. Further, we found that isolated males had significantly smaller brains than group-housed controls and larger lateral ventricles...... have evaluated the neuroanatomical changes in this animal model in comparison to changes seen in schizophrenia. In this study, we applied stereological volume estimates to evaluate the total brain, the ventricular system, and the pyramidal and granular cell layers of the hippocampus in male and female...... than controls. However, this was not seen in female rats. Isolated males had a significant smaller hippocampus, dentate gyrus and CA2/3 where isolated females had a significant smaller CA1 compared to controls. Thus, our results indicate that long-term isolation of male rats leads to neuroanatomical...

  20. Stereological quantification of lymphocytes in skin biopsies from atopic dermatitis patients

    DEFF Research Database (Denmark)

    Ellingsen, A R; Sørensen, F B; Larsen, Jytte Overgaard

    2001-01-01

    with active eczema in 8 adults with AD and from clinically normal skin from 4 of the patients. Five persons without allergy or skin disease served as controls. The mean number of lymphocytes in 4-mm skin biopsies was 469,000 and 124,000 in active eczema and in clinically normal skin, respectively. Compared......Atopic dermatitis (AD) is histologically characterized by lymphocytic infiltration of the skin and quantitative assessment is required. This study introduces stereological techniques to quantify the number of lymphocytes in skin biopsies. Four-millimetre punch biopsies were taken from skin...... with controls, the number of lymphocytes in biopsies increased by a factor of 6.8 in active eczema and a factor of 1.8 in clinically normal skin. If 20% of skin is affected by eczema the total number of lymphocytes located in the affected skin can be estimated to 1.27 x 10(10). A patient with clinically...

  1. Stereological, functional and molecular studies of development and disease : a collection of published works 1981 to 2013

    OpenAIRE

    Bertram, John F.

    2016-01-01

    The unifying theme throughout this Doctorate of Science thesis is the development, refinement and utilisation of stereological techniques to study tissue structures in development, and in adult health and disease. Stereology is the discipline based on geometric probability theory that enables us to quantify structures in three-dimensional space. Stereological techniques are often applied in material science as well as biomedical science. When applied to histology and pathology, stereology can...

  2. Stereology of human myometrium in pregnancy: influence of maternal body mass index and age.

    LENUS (Irish Health Repository)

    Sweeney, Eva M

    2013-04-01

    Knowledge of the stereology of human myometrium in pregnancy is limited. Uterine contractile performance may be altered in association with maternal obesity and advanced maternal age. The aim of this study was to investigate the stereology of human myometrium in pregnancy, and to evaluate a potential influence of maternal body mass index (BMI) and age.

  3. Assessing the Effects of Fibrosis on Lung Function by Light Microscopy-Coupled Stereology

    DEFF Research Database (Denmark)

    Pilecki, Bartosz; Sørensen, Grith Lykke

    2017-01-01

    Pulmonary diseases such as fibrosis are characterized by structural abnormalities that lead to impairment of proper lung function. Stereological analysis of serial tissue sections allows detection and quantitation of subtle changes in lung architecture. Here, we describe a stereology-based method...

  4. The total number of Leydig and Sertoli cells in the testes of men across various age groups - a stereological study

    DEFF Research Database (Denmark)

    Petersen, Peter M; Seierøe, Karina; Pakkenberg, Bente

    2015-01-01

    is particularly sensitive to methodological problems. Therefore, using the optical fractionator technique and a sampling design specifically optimized for human testes, we estimated the total number of Sertoli and Leydig cells in the testes from 26 post mortem male subjects ranging in age from 16 to 80 years...... of Sertoli cells with age; no such decline was found for Leydig cells. Quantitative stereological analysis of post mortem tissue may help understand the influence of age or disease on the number of human testicular cells....

  5. Practicable methods for histological section thickness measurement in quantitative stereological analyses.

    Science.gov (United States)

    Matenaers, Cyrill; Popper, Bastian; Rieger, Alexandra; Wanke, Rüdiger; Blutke, Andreas

    2018-01-01

    of SR to efficiently provide accurate section thickness measurements as a prerequisite for reliable estimates of dependent quantitative stereological parameters.

  6. Quantifying Golgi structure using EM: combining volume-SEM and stereology for higher throughput.

    Science.gov (United States)

    Ferguson, Sophie; Steyer, Anna M; Mayhew, Terry M; Schwab, Yannick; Lucocq, John Milton

    2017-06-01

    Investigating organelles such as the Golgi complex depends increasingly on high-throughput quantitative morphological analyses from multiple experimental or genetic conditions. Light microscopy (LM) has been an effective tool for screening but fails to reveal fine details of Golgi structures such as vesicles, tubules and cisternae. Electron microscopy (EM) has sufficient resolution but traditional transmission EM (TEM) methods are slow and inefficient. Newer volume scanning EM (volume-SEM) methods now have the potential to speed up 3D analysis by automated sectioning and imaging. However, they produce large arrays of sections and/or images, which require labour-intensive 3D reconstruction for quantitation on limited cell numbers. Here, we show that the information storage, digital waste and workload involved in using volume-SEM can be reduced substantially using sampling-based stereology. Using the Golgi as an example, we describe how Golgi populations can be sensed quantitatively using single random slices and how accurate quantitative structural data on Golgi organelles of individual cells can be obtained using only 5-10 sections/images taken from a volume-SEM series (thereby sensing population parameters and cell-cell variability). The approach will be useful in techniques such as correlative LM and EM (CLEM) where small samples of cells are treated and where there may be variable responses. For Golgi study, we outline a series of stereological estimators that are suited to these analyses and suggest workflows, which have the potential to enhance the speed and relevance of data acquisition in volume-SEM.

  7. Stereological Cell Morphometry In Right Atrium Myocardium Of Primates

    Science.gov (United States)

    Mandarim-De-Lacerda, Carlos A...; Hureau, Jacques

    1986-07-01

    The mechanism by which the cardiac impulse is propagated in normal hearts from its origin in the sinus node to the atrio-ventricular node has not been agreed on fully. We studied the "internodal posterior tract" through the crista terminalis by light microscopy and stereological morphometry. The hearts of 12 Papio cynocephalus were perfused , after sacrifice,with phosphate-buffered formol saline. The regions of the crista terminalis (CT), interatrial septum (IAS), atrioventricular bundle (AVB) and interventricular septum (IVS) were cut off and embedded in paraplast and sectioned (10 4m). The multipurpose test system M 42 was superimposed over the photomicrographs (1,890 points test, ESR = 2%) to the stereological computing. The quantitative results show that the cells from CT were more closely relationed with IAS cells than others cells (IVS and AVB cells). This results are not a morphological evidence to establish the specificity of the "internodal posterior tract". The cellular arrangement and anatomical variation in CT myocardium is very important.

  8. Weed control based on real time patchy application of herbicides using image analysis as a non-destructive estimation method for weed infestation and herbicide effects

    DEFF Research Database (Denmark)

    Asif, Ali

    There is an increasing concern about excessive use of herbicides for weed control in arable lands. Usually the whole field is sprayed uniformly, while the distribution of weeds often is non-uniform. Often there are spots in a field where weed pressure is very low and has no significant effect...... on crop yield. The excessive use of spraying can potentially be reduced by spraying only those parts of the field where it has economic importance. The competition relation between weeds and crop was ana-lyzed in context of real time patch spray. A non-destructive image analysis method was developed...

  9. Nondestructive testing 89

    International Nuclear Information System (INIS)

    1989-01-01

    The proceedings contain 24 contributions, out of which 14 have been inputted in INIS. These deal with materials for nondestructive testing and various nondestructive testing systems, with the evaluation of radiograms and with the application of radiographic, ultrasonic and eddy current methods to the detection of defects in materials, to the inspection of nuclear reactor components and in other fields of technology. (B.S.)

  10. The Optical Fractionator Technique to Estimate Cell Numbers in a Rat Model of Electroconvulsive Therapy

    DEFF Research Database (Denmark)

    Olesen, Mikkel Vestergaard; Needham, Esther Kjær; Pakkenberg, Bente

    2017-01-01

    are too high to count manually, and stereology is now the technique of choice whenever estimates of three-dimensional quantities need to be extracted from measurements on two-dimensional sections. All stereological methods are in principle unbiased; however, they rely on proper knowledge about...

  11. Microstructure characterization via stereological relations — A shortcut for beginners

    Energy Technology Data Exchange (ETDEWEB)

    Pabst, Willi, E-mail: pabstw@vscht.cz; Gregorová, Eva; Uhlířová, Tereza

    2015-07-15

    Stereological relations that can be routinely applied for the quantitative characterization of microstructures of heterogeneous single- and two-phase materials via global microstructural descriptors are reviewed. It is shown that in the case of dense, single-phase polycrystalline materials (e.g., transparent yttrium aluminum garnet ceramics) two quantities have to be determined, the interface density (or, equivalently, the mean chord length of the grains) and the mean curvature integral density (or, equivalently, the Jeffries grain size), while for two-phase materials (e.g., highly porous, cellular alumina ceramics), one additional quantity, the volume fraction (porosity), is required. The Delesse–Rosiwal law is recalled and size measures are discussed. It is shown that the Jeffries grain size is based on the triple junction line length density, while the mean chord length of grains is based on the interface density (grain boundary area density). In contrast to widespread belief, however, these two size measures are not alternative, but independent (and thus complementary), measures of grain size. Concomitant with this fact, a clear distinction between linear and planar grain size numbers is proposed. Finally, based on our concept of phase-specific quantities, it is shown that under certain conditions it is possible to define a Jeffries size also for two-phase materials and that the ratio of the mean chord length and the Jeffries size has to be considered as an invariant number for a certain type of microstructure, i.e., a characteristic value that is independent of the absolute size of the microstructural features (e.g., grains, inclusions or pores). - Highlights: • Stereology-based image analysis is reviewed, including error considerations. • Recipes are provided for measuring global metric microstructural descriptors. • Size measures are based on interface density and mean curvature integral density. • Phase-specific quantities and a generalized

  12. Brain Volume Estimation Enhancement by Morphological Image Processing Tools

    Directory of Open Access Journals (Sweden)

    Zeinali R.

    2017-12-01

    Full Text Available Background: Volume estimation of brain is important for many neurological applications. It is necessary in measuring brain growth and changes in brain in normal/ abnormal patients. Thus, accurate brain volume measurement is very important. Magnetic resonance imaging (MRI is the method of choice for volume quantification due to excellent levels of image resolution and between-tissue contrast. Stereology method is a good method for estimating volume but it requires to segment enough MRI slices and have a good resolution. In this study, it is desired to enhance stereology method for volume estimation of brain using less MRI slices with less resolution. Methods: In this study, a program for calculating volume using stereology method has been introduced. After morphologic method, dilation was applied and the stereology method enhanced. For the evaluation of this method, we used T1-wighted MR images from digital phantom in BrainWeb which had ground truth. Results: The volume of 20 normal brain extracted from BrainWeb, was calculated. The volumes of white matter, gray matter and cerebrospinal fluid with given dimension were estimated correctly. Volume calculation from Stereology method in different cases was made. In three cases, Root Mean Square Error (RMSE was measured. Case I with T=5, d=5, Case II with T=10, D=10 and Case III with T=20, d=20 (T=slice thickness, d=resolution as stereology parameters. By comparing these results of two methods, it is obvious that RMSE values for our proposed method are smaller than Stereology method. Conclusion: Using morphological operation, dilation allows to enhance the estimation volume method, Stereology. In the case with less MRI slices and less test points, this method works much better compared to Stereology method.

  13. Assessment of in vivo MR imaging compared to physical sections in vitro-A quantitative study of brain volumes using stereology

    DEFF Research Database (Denmark)

    Jelsing, Jacob; Rostrup, Egill; Markenroth, Karin

    2005-01-01

    The object of the present study was to compare stereological estimates of brain volumes obtained in vivo by magnetic resonance imaging (MRI) to corresponding volumes from physical sections in vitro. Brains of ten domestic pigs were imaged using a 3-T scanner. The volumes of different brain....... However, although intraobserver difference of MRI estimates was acceptable, the interobserver difference was not. A statistical highly significant difference of 11-41% was observed between observers for volume estimates of all compartments considered. The study demonstrates that quantitative MRI...

  14. No postnatal doubling of number of neurons in human Broca's areas (Brodmann areas 44 and 45)? A stereological study.

    Science.gov (United States)

    Uylings, H B M; Malofeeva, L I; Bogolepova, I N; Jacobsen, A M; Amunts, K; Zilles, K

    2005-01-01

    In this study we explored whether a postnatal doubling of the total number of neurons occurs in the human Brodmann areas 44 and 45 (Broca's area). We describe the most recent error prediction formulae and their application for the modern stereological estimators for volume and number of neurons. We estimated the number of neurons in 3D optical disector probes systematically random sampled throughout the entire Brodmann areas (BA) 44 and 45 in developing and young adult cases. In the relatively small number of male and female cases studied no substantial postnatal increase in total number of neurons occurred in areas 44 and 45; the volume of these areas reached adult values around 7 years. In addition, we did find indications that a shift from a right-over-left to a left-over-right asymmetry may occur in the volume of BA 45 during postnatal development. No major asymmetry in total number of neurons in BA 44 and 45 was detected.

  15. Nondestructive testing method

    International Nuclear Information System (INIS)

    Porter, J.F.

    1996-01-01

    Nondestructive testing (NDT) is the use of physical and chemical methods for evaluating material integrity without impairing its intended usefulness or continuing service. Nondestructive tests are used by manufaturer's for the following reasons: 1) to ensure product reliability; 2) to prevent accidents and save human lives; 3) to aid in better product design; 4) to control manufacturing processes; and 5) to maintain a uniform quality level. Nondestructive testing is used extensively on power plants, oil and chemical refineries, offshore oil rigs and pipeline (NDT can even be conducted underwater), welds on tanks, boilers, pressure vessels and heat exchengers. NDT is now being used for testing concrete and composite materials. Because of the criticality of its application, NDT should be performed and the results evaluated by qualified personnel. There are five basic nondestructive examination methods: 1) liquid penetrant testing - method used for detecting surface flaws in materials. This method can be used for metallic and nonmetallic materials, portable and relatively inexpensive. 2) magnetic particle testing - method used to detect surface and subsurface flaws in ferromagnetic materials; 3) radiographic testing - method used to detect internal flaws and significant variation in material composition and thickness; 4) ultrasonic testing - method used to detect internal and external flaws in materials. This method uses ultrasonics to measure thickness of a material or to examine the internal structure for discontinuities. 5) eddy current testing - method used to detect surface and subsurface flaws in conductive materials. Not one nondestructive examination method can find all discontinuities in all of the materials capable of being tested. The most important consideration is for the specifier of the test to be familiar with the test method and its applicability to the type and geometry of the material and the flaws to be detected

  16. Effects of melatonin on diclofenac sodium treated rat kidney: a stereological and histopathological study.

    Science.gov (United States)

    Khoshvakhti, Habib; Yurt, K Kübra; Altunkaynak, B Zuhal; Türkmen, Aysın P; Elibol, Ebru; Aydın, Işınsu; Kıvrak, Elfide G; Önger, M Emin; Kaplan, Süleyman

    2015-01-01

    In this study, we aimed to investigate the effect of diclofenac sodium (DS) and melatonin (MEL) on kidney of the prenatally administered rats. Pregnant rats were divided into the control, physiological saline, DS, and DS + MEL groups. All injections were given beginning from the 5th day after mating to the 15th day of the pregnancy. Physical dissector and Cavalieri principle were used to estimate the numerical density and total number of glomeruli and the volumetric parameters of kidney, respectively. Our stereological results indicated that DS application during the pregnancy lead to decrease in the mean volume, numerical density, and total number of the glomeruli (p  0.05). Light microscopic investigation showed congestion in blood vessels and shrinkage of the Bowman's space in the DS group. Moreover, there was degeneration in nephrons including glomerulosclerosis and tubular defects, and an increase in the connective tissue in the kidneys of the DS-treated group. However, usage of the MEL with the DS caused preventing of these pathological alterations in the kidney. We suggested that DS might lead to adverse effects in the kidneys of the rats that are prenatally subjected to this drug. Fortunately, these adverse effects can be prevented by the melatonin supplementation.

  17. Effect of hindlimb unloading on stereological parameters of the motor cortex and hippocampus in male rats.

    Science.gov (United States)

    Salehi, Mohammad Saied; Mirzaii-Dizgah, Iraj; Vasaghi-Gharamaleki, Behnoosh; Zamiri, Mohammad Javad

    2016-11-09

    Hindlimb unloading (HU) can cause motion and cognition dysfunction, although its cellular and molecular mechanisms are not well understood. The aim of the present study was to determine the stereological parameters of the brain areas involved in motion (motor cortex) and spatial learning - memory (hippocampus) under an HU condition. Sixteen adult male rats, kept under a 12 : 12 h light-dark cycle, were divided into two groups of freely moving (n=8) and HU (n=8) rats. The volume of motor cortex and hippocampus, the numerical cell density of neurons in layers I, II-III, V, and VI of the motor cortex, the entire motor cortex as well as the primary motor cortex, and the numerical density of the CA1, CA3, and dentate gyrus subregions of the hippocampus were estimated. No significant differences were observed in the evaluated parameters. Our results thus indicated that motor cortical and hippocampal atrophy and cell loss may not necessarily be involved in the motion and spatial learning memory impairment in the rat.

  18. Ultrastructural and stereological analysis of trypanosomatidis of the genus Endotrypanum

    Directory of Open Access Journals (Sweden)

    Maurílio J. Soares

    1991-06-01

    Full Text Available Culture forms of four strains of Endotrypanum (E. schaudinni and E. monterogeii were processed for transmission electron microscopy and analyzed at the ultrastructural level. Quantitative data about some cytoplasmic organelles were obeined by stereology. All culture forms were promastigotes. In their cytoplasm four different organelles could be found: lipid inclusions (0,2-0,4 µm in diameter, mebrane-bounded vacuoles (0.10-0,28 µm in diameter, glycosomes (0,2-0,3 µm in diameter, and the mitochondrion. The kenetoplast appears as a thin band, except for the strain IM201, which possesses a broader structure, and possibly is not a member of this genus. Clusters of virus-like particles were seen in the cytoplasm of the strain LV88. The data obtained show that all strains have the typical morphological feature of the trypanosomatids. Only strain IM201 could be differentiated from the others, due to its larger kenetoplast-DNA network and its large mitochondrial and glycosomal relative volume. The morphometrical data did not allow the differentiation between E. schaudinni (strains IM217 and M6226 and E. monterogeii (strain LV88.

  19. CONDITIONS FOR EXACT CAVALIERI ESTIMATION

    Directory of Open Access Journals (Sweden)

    Mónica Tinajero-Bravo

    2014-03-01

    Full Text Available Exact Cavalieri estimation amounts to zero variance estimation of an integral with systematic observations along a sampling axis. A sufficient condition is given, both in the continuous and the discrete cases, for exact Cavalieri sampling. The conclusions suggest improvements on the current stereological application of fractionator-type sampling.

  20. Stereological quantification of tumor volume, mean nuclear volume and total number of melanoma cells correlated with morbidity and mortality

    DEFF Research Database (Denmark)

    Bønnelykke-Behrndtz, Marie Louise; Sørensen, Flemming Brandt; Damsgaard, Tine Engberg

    2008-01-01

    potential indicators of prognosis. Sixty patients who underwent surgery at the Department of Plastic Surgery, Aarhus University Hospital, from 1991 to 1994 were included in the study. Total tumor volume was estimated by the Cavalieri technique, total number of tumor cells by the optical dissector principle...... showed a significant impact on both disease-free survival (p=0.001) and mortality (p=0.009). In conclusion, tumor volume and total number of cancer cells were highly reproducible but did not add additional, independent prognostic information regarding the study population.......Stereological quantification of tumor volume, total number of tumor cells and mean nuclear volume provides unbiased data, regardless of the three-dimensional shape of the melanocytic lesion. The aim of the present study was to investigate whether these variables are reproducible and may represent...

  1. Non-destructive controls

    International Nuclear Information System (INIS)

    Nouvet, A.

    1978-01-01

    The non-destructive controls permit, while respecting their integrity, the direct and individual examination of parts or complete objects as they are manufactured, as well as to follow the evolution of their eventual defects while in operation. The choice of control methods depends on the manufacturing process and shapes of parts, on the physical properties of their components as well as the nature, position and size of the defects which are likely to be detected. Whether it is a question of controls by means of ionizing radiation, flux of neutrons, ultrasons, acoustic source, sweating, magnetoscopy. Foucault currents, thermography, detection of leaks or non-destructive metallography, each has a limited field of application such that they are less competitive than complementary [fr

  2. Nondestructive testing: welding industry

    International Nuclear Information System (INIS)

    Raj, Baldev; Subramanian, C.V.

    1992-01-01

    This chapter highlights various conventional and advanced nondestructive testing (NDT) techniques that have been used for weld evaluation. Welding Codes and Standards of International and National organisations that have been followed in India for various weld evaluation purposes are also included. The chapter also emphasises the importance of NDT by way of a few case studies that have been carried out on important critical welded components. (author). 12 refs., 17 figs., 1 appendix

  3. Nondestructive analysis and development

    Science.gov (United States)

    Moslehy, Faissal A.

    1993-01-01

    This final report summarizes the achievements of project #4 of the NASA/UCF Cooperative Agreement from January 1990 to December 1992. The objectives of this project are to review NASA's NDE program at Kennedy Space Center (KSC) and recommend means for enhancing the present testing capabilities through the use of improved or new technologies. During the period of the project, extensive development of a reliable nondestructive, non-contact vibration technique to determine and quantify the bond condition of the thermal protection system (TPS) tiles of the Space Shuttle Orbiter was undertaken. Experimental modal analysis (EMA) is used as a non-destructive technique for the evaluation of Space Shuttle thermal protection system (TPS) tile bond integrity. Finite element (FE) models for tile systems were developed and were used to generate their vibration characteristics (i.e. natural frequencies and mode shapes). Various TPS tile assembly configurations as well as different bond conditions were analyzed. Results of finite element analyses demonstrated a drop in natural frequencies and a change in mode shapes which correlate with both size and location of disbond. Results of experimental testing of tile panels correlated with FE results and demonstrated the feasibility of EMA as a viable technique for tile bond verification. Finally, testing performed on the Space Shuttle Columbia using a laser doppler velocimeter demonstrated the application of EMA, when combined with FE modeling, as a non-contact, non-destructive bond evaluation technique.

  4. STEREOLOGICAL STUDIES ON FETAL VASCULAR DEVELOPMENT IN HUMAN PLACENTAL VILLI

    Directory of Open Access Journals (Sweden)

    Terry M Mayhew

    2011-05-01

    Full Text Available In human pregnancy, fetal well-being depends on the development of placental villi and the creation and maintenance of fetal microvessels within them. The aim of this study was to define stereological measures of the growth, capillarization and maturation of villi and of fetoplacental angiogenesis and capillary remodelling. Placentas were collected at 12-41 weeks of gestation and assigned to six age groups spanning equal age ranges. Tissue samples were randomised for position and orientation. Overall growth of peripheral (intermediate and terminal villi and their capillaries was evaluated using total volumes, surface areas and lengths. Measures of villous capillarization comprised capillary volume, surface and length densities and capillary:villus surface and length ratios. Size and shape remodelling of villi and capillaries was assessed using mean cross-sectional areas, perimeters and shape coefficients (perimeter2/area. Group comparisons were drawn by analysis of variance. Villous and capillary volumes, surfaces and lengths increased significantly throughout gestation. Villous maturation involved phasic (capillary:villus surface and length ratios or progressive (volume, surface and length densities increases in indices of villous capillarization. It also involved isomorphic thinning (cross-sectional areas and perimeters declined but shape coefficients did not alter. In contrast, growth of capillaries did not involve changes in luminal areas or perimeters. The results show that villous growth and fetal angiogenesis involve increases in overall length rather than calibre and that villous differentiation involves increased capillarization. Although they do not distinguish between increases in the lengths versus numbers of capillary segments, other studies have shown that capillaries switch from branching to non-branching angiogenesis during gestation. Combined with maintenance of capillary calibres, these processes will contribute to the reduced

  5. Stereology application in the investigation of physical and mechanical properties of porous materials

    International Nuclear Information System (INIS)

    Cytermann, Richard.

    1979-04-01

    The sintering of carbonyl nickel powders has been studied through stereology (quantitative microscopy) associated with different physical and mechanical measurements. This study demonstrated that a set of stereological parameters, such as porosity, grain size, mean pore volume ..., was necessary to characterize porous parts with the same porosity obtained through different ways. On the one hand, stereology permitted to elucidate powder shape and speed of pressure rising influence on the compacting process. On the other hand, the study of physical and mechanical properties related to their microstructure led to distinguish: properties such as elasticity modulus independant of compacting pressure, sintering temperature and powder shape. Their evolution has been characterized through contiguity coefficient; properties such as tensile strength dependant of sintering parameters. Their characterization required the simultaneous measurement of porosity mean pore volume, shape factor and grain size [fr

  6. Some new, simple and efficient stereological methods and their use in pathological research and diagnosis

    DEFF Research Database (Denmark)

    Gundersen, H J; Bendtsen, T F; Korbo, L

    1988-01-01

    Stereology is a set of simple and efficient methods for quantitation of three-dimensional microscopic structures which is specifically tuned to provide reliable data from sections. Within the last few years, a number of new methods has been developed which are of special interest to pathologists...... are invariably simple and easy....

  7. Unbiased stereological methods used for the quantitative evaluation of guided bone regeneration

    DEFF Research Database (Denmark)

    Aaboe, Else Merete; Pinholt, E M; Schou, S

    1998-01-01

    The present study describes the use of unbiased stereological methods for the quantitative evaluation of the amount of regenerated bone. Using the principle of guided bone regeneration the amount of regenerated bone after placement of degradable or non-degradable membranes covering defects...

  8. Technical regulation of nondestructive inspection

    International Nuclear Information System (INIS)

    1995-01-01

    It starts with the explanation of definition of nondestructive inspection and qualifications for a inspection. It lists the technical regulations of nondestructive inspections which are radiographic testing, ultrasonic flaw detecting test, liquid penetrant test, magnetic particle inspection, eddy current test visual inspection and leakage test.

  9. An economical non-destructive method for estimating eelgrass, Zostera marina (Potamogetonaceae leaf growth rates: formal development and use in northwestern Baja California

    Directory of Open Access Journals (Sweden)

    Elena Solana-Arellano

    2008-09-01

    Full Text Available Seagrass beds provide much of the primary production in estuaries; host many fishes and fish larvae, and abate erosion. The present study presents original analytical methods for estimating mean leaf-growth rates of eelgrass (Zostera marina. The method was calibrated by using data collected in a Z. marina meadow at Punta Banda estuary in Baja California, Mexico. The analytical assessments were based on measurements of leaf length and standard regression procedures. We present a detailed explanation of the formal procedures involved in the derivation of these analytical methods. The measured daily leaf-growth rate was 10.9 mm d-1 leaf-1. The corresponding value projected by our method was 10.2 mm d-1 leaf-1. The associated standard errors were of 0.53 and 0.56 mm d-1 leaf-1 respectively. The method was validated by projecting leaf-growth rates from an independent data set, which gave consistent results. The use of the method to obtain the mean leaf growth rate of a transplanted plot is also illustrated. Comparison of our leaf-growth data with previously reported assessments show the significant forcing of sea-surface temperature on eelgrass leaf dynamics. The formal constructs provided here are of general scope and can be applied to equivalent eelgrass data sets in a straightforward manner. Rev. Biol. Trop. 56 (3: 1003-1013. Epub 2008 September 30.Las praderas de pastos marinos abaten la erosión y aportan gran parte de la productividad primaria de los esteros y son refugio de muchos peces y sus larvas. El presente trabajo introduce métodos analíticos para estimar las tasas medias de crecimiento foliar de Zostera marina L. y sus varianzas. La calibración del método se llevó a cabo utilizando datos de una pradera de esta fanerógama en el Estero de Punta Banda Baja California, México. Las referidas estimaciones analíticas, se basan en medias de longitud foliar y en procedimientos estandarizados de regresión. Dichas determinaciones son por

  10. Nondestructive estimation of leaf area for pondberry

    Science.gov (United States)

    Brian Roy Lockhart; Emile S. Gardiner; Theran P. Stautz; Theodore D. Leininger; Paul B. Hamel; Kristina F. Connor; Nathan M. Schiff; A. Dan Wilson; Margaret S. Devall

    2007-01-01

    Pondberry (Lindera melissifolia [Walt.] Blume) is a federally listed endangered shrub found as isolated populations in seasonally flooded forests across the Southeastern United States. Because this shrub is rare, it has received little research attention, and basic knowledge of its ecology and physiology is lacking. To facilitate future ecological...

  11. Non-destructive inservice inspections

    International Nuclear Information System (INIS)

    Kauppinen, P.; Sarkimo, M.; Lahdenperae, K.

    1998-01-01

    In order to assess the possible damages occurring in the components and structures of operating nuclear power plants during service the main components and structures are periodically inspected by non-destructive testing techniques. The reliability of non-destructive testing techniques applied in these inservice inspections is of major importance because the decisions concerning the needs for repair of components are mainly based on the results of inspections. One of the targets of this research program has been to improve the reliability of non-destructive testing. This has been addressed in the sub-projects which are briefly summarised here. (author)

  12. A simple and efficient alternative to implementing systematic random sampling in stereological designs without a motorized microscope stage.

    Science.gov (United States)

    Melvin, Neal R; Poda, Daniel; Sutherland, Robert J

    2007-10-01

    When properly applied, stereology is a very robust and efficient method to quantify a variety of parameters from biological material. A common sampling strategy in stereology is systematic random sampling, which involves choosing a random sampling [corrected] start point outside the structure of interest, and sampling relevant objects at [corrected] sites that are placed at pre-determined, equidistant intervals. This has proven to be a very efficient sampling strategy, and is used widely in stereological designs. At the microscopic level, this is most often achieved through the use of a motorized stage that facilitates the systematic random stepping across the structure of interest. Here, we report a simple, precise and cost-effective software-based alternative to accomplishing systematic random sampling under the microscope. We believe that this approach will facilitate the use of stereological designs that employ systematic random sampling in laboratories that lack the resources to acquire costly, fully automated systems.

  13. Quantification of rat retinal growth and vascular population changes after single and split doses of proton irradiation: translational study using stereology methods

    Science.gov (United States)

    Mao, Xiao W.; Archambeau, John O.; Kubinova, Lucie; Boyle, Soames; Petersen, Georgia; Grove, Roger; Nelson, G. A. (Principal Investigator)

    2003-01-01

    This study quantified architectural and population changes in the rat retinal vasculature after proton irradiation using stereology. A 100 MeV conformal proton beam delivered 8, 14, 20 and 28 Gy as single and split doses to the whole eye. The vascular networks were prepared from retinal digests. Stereological methods were used to obtain the area of the retina and unbiased estimates of microvessel/artery/vein endothelial, pericyte and smooth muscle population, and vessel length. The retinal area increased progressively in the unirradiated, age-matched controls and in the retinas irradiated with 8 and 14 Gy, indicating uniform progressive retinal growth. No growth occurred after 20 and 28 Gy. Regression analysis of total endothelial cell number in all vessels (arteries, veins and capillaries) after irradiation documented a progressive time- and dose-dependent cell loss occurring over 15 to 24 months. The difference from controls was significant (Ppopulations after split doses. At 10 Gy, the rate of endothelial cell loss, a dose parameter used to characterize the time- and dose-dependent loss of the endothelial population, was doubled.

  14. Industrial strategy for nondestructive control

    International Nuclear Information System (INIS)

    Martin, P.; Michaut, J.P.

    1994-01-01

    For Electricite de France, the nondestructive control strategy passes by a responsibility of services, a competition between companies, a clarification of the market access and a dialogue with the companies

  15. A review of state-of-the-art stereology for better quantitative 3D morphology in cardiac research.

    Science.gov (United States)

    Mühlfeld, Christian; Nyengaard, Jens Randel; Mayhew, Terry M

    2010-01-01

    The aim of stereological methods in biomedical research is to obtain quantitative information about three-dimensional (3D) features of tissues, cells, or organelles from two-dimensional physical or optical sections. With immunogold labeling, stereology can even be used for the quantitative analysis of the distribution of molecules within tissues and cells. Nowadays, a large number of design-based stereological methods offer an efficient quantitative approach to intriguing questions in cardiac research, such as "Is there a significant loss of cardiomyocytes during progression from ventricular hypertrophy to heart failure?" or "Does a specific treatment reduce the degree of fibrosis in the heart?" Nevertheless, the use of stereological methods in cardiac research is rare. The present review article demonstrates how some of the potential pitfalls in quantitative microscopy may be avoided. To this end, we outline the concepts of design-based stereology and illustrate their practical applications to a wide range of biological questions in cardiac research. We hope that the present article will stimulate researchers in cardiac research to incorporate design-based stereology into their study designs, thus promoting an unbiased quantitative 3D microscopy.

  16. Estimativa da área foliar de plantas de lima ácida 'Tahiti' usando métodos não-destrutivos Leaf area estimative of young 'Tahiti' lime using non-destructive methods

    Directory of Open Access Journals (Sweden)

    Maurício Antonio Coelho Filho

    2005-04-01

    Full Text Available O objetivo desse estudo foi avaliar métodos não-destrutivos para a determinação da área foliar de plantas jovens de lima ácida 'Tahiti'(Citrus latifolia Tan., em campo. Foram utilizadas informações de variáveis biométricas de 28 plantas jovens (0,07 a 1,44 m² e imagens digitais da área frontal de cada planta (silhueta de copa. Essas variáveis foram correlacionadas com medidas diretas (contagem total de folhas x área foliar média. Como resultado, foi possível estimar a área foliar total das plantas (AFT com base na equação: AFT = 88,936 x DI - 1,4017 (R²=0,75, em que DI representa o diâmetro do caule 5 cm abaixo do ponto em que a copa foi enxertada, e a silhueta da planta em m² (IM: AFT = 2,4951 x IM (R²=0,72. A área foliar dos ramos secundários das plantas (AFR pode ser estimada mediante uma equação exponencial envolvendo o diâmetro do ramo (DR: AFR = 0,0144e277,02 x DR (R²=0,71. Estas metodologias podem ser utilizadas quando o interesse for por um valor médio de área foliar no pomar, não sendo indicadas quando é necessária elevada precisão, pois os erros são elevados.The objective of this study was to evaluate non-destructive methods of estimating total leaf area of young 'Tahiti' lime (Citrus latifolia Tan. plants grown in the field. Information of biometrical variables of 28 young plants (0.07 to 1.44 m² and digitized image of front area of each plant (plant silhouette were used. These variables were correlated to the direct measurements (leaves and average leaf area counting. As a result, it was possible to estimate total plant leaf area (AFT based upon the equation: AFT = 88.936 x DI - 1.4017 (R²=0.75, where DI stands for the trunk diameter taken 5 cm below the graft and the silhouette area in m² (IM: AFT = 2.4951 x IM (R²=0.72. The leaf area of secondary branches (AFR can be estimated by an exponential equation with the branch diameter (DR: AFR = 0.0144e277.02 x DR (R²=0.71. These methodologies can

  17. Nondestructive testing of materials

    International Nuclear Information System (INIS)

    NUKEM has transferred know-how from reactor technology to materials testing. The high and to a large extent new quality standards in the nuclear industry necessitate reliable measuring and testing equipment of the highest precision. Many of the tasks presented to us could not be solved with the equipment available on the market, for which reason we have developed our own measuring, testing and control systems. We have therefore acquired considerable experience in dealing with specific measuring, testing and control tasks and can handle even out-of-the-way problems that are submitted to us from a wide variety of fields. Our mechanical systems for the checking of close-tolerance gaps, the automatic determination of pellet dimensions and the measurement of absolute lengths and absolute velocities are in use in many different industrial fields. We have succeeded in solving unusual testing and sorting problems with the aid of automated surface testing equipment working on optical principles. Our main activities in the field of non-destructive testing have been concentrated on ultrasonic and eddy current testing and, of late, acoustic emission analysis. NUKEM ultrasonic systems are notable for their high defect detection rate and testing accuracy, combined with high testing speed. The equipment we supply includes ultrasonic rotary systems for the production testing of quality tubes, ultrasonic immersion systems for the final testing of reactor cladding tubes, weld testing equipment, and test equipment for the bonds in multi-layer plates. (orig./RW) [de

  18. Nondestructive Testing with Shearography

    International Nuclear Information System (INIS)

    Chang, Seog Weon

    2001-01-01

    Nondestructive testing(NDT) is one of the fundamental tools to improve the quality of commercial and industrial products. NDT is potentially a major application of interferometry. Interferometry(ESPI, Shearography, ect) has successfully been applied in various industrial environments such as high performance aircraft, home appliance, automotive, and laminates on engine structures, etc. Today's industry demands high performance components with toughest mechanical features and ultimate safety standards. Especially in automotive and aircraft industry the development process focuses on tailor-made design and solutions to meet customer specifications. To reconcile economy, ligh-weight construction has become a key issue. Many companies are looking for new advanced NDT techniques to archive cost efficiency over the limitations of classical methods. ESPI and shearography allow a rapid, full field and 3D-measurement without contact. In this paper recent applications of ESPI and shearography for NDT are described. Advanced features of classical techniques are specified and new applications in material and component testing are presented

  19. UTILIZATION OF STEREOLOGY FOR QUANTITATIVE ANALYSIS OF PLASTIC DEFORMATION OF FORMING PIECES

    Directory of Open Access Journals (Sweden)

    Maroš Martinkovič

    2012-01-01

    Full Text Available Mechanical working leads to final properties of forming pieces, which are affected by conditions of production technology. Utilization of stereology leads to the detail analysis of three-dimensional plastic deformed material structure by different forming technologies, e.g. forging, extruding, upsetting, metal spinning, drawing etc. The microstructure of cold drawing wires was analyzed. Grain boundaries orientation was measured on the parallel section of wire with a different degree of deformation and direct axis plastic deformation was evaluated in bulk formed part. The strain of probes on their sections was obtained using stereology by measurement of degree of grain boundary orientation which was converted to deformation using model of conversion of grain boundary orientation degree to deformation.

  20. Comparison of quantitative estimation of intracerebral hemorrhage and infarct volumes after thromboembolism in an embolic stroke model

    DEFF Research Database (Denmark)

    Eriksen, Nina; Rasmussen, Rune Skovgaard; Overgaard, Karsten

    2014-01-01

    . Group 1 was treated with saline, and group 2 was treated with 20 mg/kg recombinant tissue plasminogen activator to promote intracerebral hemorrhages. Stereology, semiautomated computer estimation, and manual erythrocyte counting were used to test the precision and efficiency of determining the size...... measurements, the stereological method was the most efficient and advantageous. CONCLUSIONS: We found that stereology was the superior method for quantification of hemorrhagic volume, especially for rodent petechial bleeding, which is otherwise difficult to measure. Our results suggest the possibility...

  1. Stereology, an unbiased methodological approach to study plant anatomy and cytology: Past, present and future

    Czech Academy of Sciences Publication Activity Database

    Kubínová, Lucie; Radochová, Barbora; Lhotáková, Z.; Kubínová, Z.; Albrechtová, J.

    2017-01-01

    Roč. 36, č. 3 (2017), s. 187-205 ISSN 1580-3139 R&D Projects: GA MŠk(CZ) LM2015062 Institutional support: RVO:67985823 Keywords : chloroplast * confocal microscopy * leaf anatomy * mesophyll * stereological methods * systematic uniform random sampling Subject RIV: FS - Medical Facilities ; Equipment OBOR OECD: Medical laboratory technology (including laboratory samples analysis Impact factor: 1.135, year: 2016

  2. Effect of Sodium Cyclamate on the Rat Fetal Exocrine Pancreas: a Karyometric and Stereological Study

    OpenAIRE

    MARTINS, Alex Tadeu; SANTOS, Fabiano de Sant`Ana dos; SCANNAVINO, Fabio Luiz Ferreira; PIRES, Juliana Rico; ZUZA, Elizangela Partata; PADOVANI JUNIOR, Joao Armando; AZOUBEL, Reinaldo; MATEO, Miguel Angel Sala Di; LOPES, Ruberval Armando

    2010-01-01

    The cyclamate, a sweetner substance derived from N-cyclo-hexyl-sulfamic acid, is largely utilized as a non-caloric artificial edulcorant in foods and beverages as well as in the pharmaceutical industry. The objective of this study was to evaluate karyometric and stereological alterations in the rat fetal pancreas resulting from the intraperitoneal administration of sodium cyclamate. The exocrine pancreas of ten fetuses of rats were evaluated, five treated and five controls chosen at random, i...

  3. Nondestructive neutron activation analysis of silicon carbide

    Energy Technology Data Exchange (ETDEWEB)

    Vandergraaf, T. T.; Wikjord, A. G.

    1973-10-15

    Instrumentel neutron activation analysis was used to determine trace constituents in silicon carbide. Four commercial powders of different origin, an NBS reference material, and a single crystal were characterized. A total of 36 activation species were identified nondestructively by high resolution gamma spectrometry; quantitative results are given for 12 of the more predominant elements. The limitations of the method for certain elements are discussed. Consideration is given to the depression of the neutron flux by impurities with large neutron absorption cross sections. Radiation fields from the various specimens were estimated assuming all radionuclides have reached their saturation activities. (auth)

  4. Radioisotopes in non-destructive testing

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1976-12-01

    After defining nondestructive testing (NDT) and comparing this concept with destructive testing, a short description is given of NDT methods other than radiologic. The basic concepts of radiologic methods are discussed and the principles of radiography are explained. Radiation sources and gamma radiography machines are next reviewed and radiographic inspection of weldings and castings is described. A brief description is given of the radiographic darkroom and accessories. Other radioisotope methods, such as neutron radiography, are shortly reviewed. Cost estimations for radioisotopic equipment conclude the report. (author)

  5. Nondestructive mechanical characterization of developing biological tissues using inflation testing.

    Science.gov (United States)

    Oomen, P J A; van Kelle, M A J; Oomens, C W J; Bouten, C V C; Loerakker, S

    2017-10-01

    One of the hallmarks of biological soft tissues is their capacity to grow and remodel in response to changes in their environment. Although it is well-accepted that these processes occur at least partly to maintain a mechanical homeostasis, it remains unclear which mechanical constituent(s) determine(s) mechanical homeostasis. In the current study a nondestructive mechanical test and a two-step inverse analysis method were developed and validated to nondestructively estimate the mechanical properties of biological tissue during tissue culture. Nondestructive mechanical testing was achieved by performing an inflation test on tissues that were cultured inside a bioreactor, while the tissue displacement and thickness were nondestructively measured using ultrasound. The material parameters were estimated by an inverse finite element scheme, which was preceded by an analytical estimation step to rapidly obtain an initial estimate that already approximated the final solution. The efficiency and accuracy of the two-step inverse method was demonstrated on virtual experiments of several material types with known parameters. PDMS samples were used to demonstrate the method's feasibility, where it was shown that the proposed method yielded similar results to tensile testing. Finally, the method was applied to estimate the material properties of tissue-engineered constructs. Via this method, the evolution of mechanical properties during tissue growth and remodeling can now be monitored in a well-controlled system. The outcomes can be used to determine various mechanical constituents and to assess their contribution to mechanical homeostasis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Stereological study of the effect of ginger's alcoholic extract on the testis in busulfan-induced infertility in rats

    Directory of Open Access Journals (Sweden)

    Hossein Bordbar

    2013-06-01

    Full Text Available Background: In traditional medicine zingiber officinale used to regulate female menstural cycle and treat male infertility. Recent studies have suggested the possible role of ginger extract in improving the testicular damage of busulfan. Objective: The aim of this study was to evaluate the effects of zingiber officinale on the sperm parameters, testosterone level and the volume of the testes and seminiferous tubules by stereological methods. Materials and Methods: Fifty rats were divided into four groups. All the rats were given a single intraperitoneally injection of 5mg/kg busulfan solution. The first group was kept as busulfan control, while the other groups were orally administrated ginger extract in graded doses of 50, 100 and 150mg/kg b.wt, for 48 consecutive days. At the end, all animals were anesthetized and their testes and vas deference were removed, fixed, embedded, and stained. The volume of testes and seminiferous tubules were estimated by cavalieri methods. Results: The result showed, that zingiber officinale increased the volumes of seminiferous tubule in 100mg/kg treated group compared to control group. Sperm count (706×105 and 682×105 and the level of testosterone (50.90 ng/mL and 54.10 ng/mL enhanced in 100 mg/kg and 150 mg/kg treated groups compared to control group (p=0.00. Conclusion: It seems that zingiber officinale stimulate male reproductive system in induce busulfan infertility

  7. x-y-recording in transmission electron microscopy. A versatile and inexpensive interface to personal computers with application to stereology.

    Science.gov (United States)

    Rickmann, M; Siklós, L; Joó, F; Wolff, J R

    1990-09-01

    An interface for IBM XT/AT-compatible computers is described which has been designed to read the actual specimen stage position of electron microscopes. The complete system consists of (i) optical incremental encoders attached to the x- and y-stage drivers of the microscope, (ii) two keypads for operator input, (iii) an interface card fitted to the bus of the personal computer, (iv) a standard configuration IBM XT (or compatible) personal computer optionally equipped with a (v) HP Graphic Language controllable colour plotter. The small size of the encoders and their connection to the stage drivers by simple ribbed belts allows an easy adaptation of the system to most electron microscopes. Operation of the interface card itself is supported by any high-level language available for personal computers. By the modular concept of these languages, the system can be customized to various applications, and no computer expertise is needed for actual operation. The present configuration offers an inexpensive attachment, which covers a wide range of applications from a simple notebook to high-resolution (200-nm) mapping of tissue. Since section coordinates can be processed in real-time, stereological estimations can be derived directly "on microscope". This is exemplified by an application in which particle numbers were determined by the disector method.

  8. Effect of Urtica dioica on morphometric indices of kidney in streptozotocin diabetic rats--a stereological study.

    Science.gov (United States)

    Golalipour, Mohammad Jafar; Gharravi, Anneh Mohammad; Ghafari, Sorya; Afshar, Mohammad

    2007-11-01

    The aim of the present study was to investigate the effect of Urtica dioica on Morphometric indices of kidney in diabetic rats. Thirty male adult albino wistar rats of 125-175 g divided into control, diabetic and Urtica dioica treatment groups. In treatment Group, diabetic rats received 100 mg kg(-1) daily hydroalcoholic extract of U. dioica intraperitoneally for 4 weeks. After the animals had been sacrified, the kidneys were removed and fixed by formaldehyde, cut horizontally into 1 mm slices and processed, Stained with H and E. Stereological study performed using light microscope and the image projected on a table of olysa software. Cavalieri principle was used to estimate the volume of cortex, medulla and whole kidney. All the grouped data statistically evaluated using Student's t-test, expressed as the Mean +/- SE. Ration of kidney weight/body weight in diabetes (0.51) and diabetes-extract group (0.67) were higher then control group (0.42). Ratio of kidney volume/body weight in diabetes (350) and diabetes-extract group (348) were higher then control group (323). Volume Ratio of cortex/medulla in diabetes-extract group (1.65) was higher then control (1.34) and diabetes group (1.33). Glomerular area and diameter and proximal tubule diameter in diabetes-Extract group was higher than control and diabetes groups. This study revealed that Urtica dioica has no effect on renal morphometric indices in induced diabetic rats.

  9. Immunocytochemical and stereological analysis of GABA(B) receptor subunit expression in the rat vestibular nucleus following unilateral vestibular deafferentation.

    Science.gov (United States)

    Zhang, Rong; Ashton, John; Horii, Arata; Darlington, Cynthia L; Smith, Paul F

    2005-03-10

    The process of behavioral recovery that occurs following damage to one vestibular labyrinth, vestibular compensation, has been attributed in part to a down-regulation of GABA(B) receptors in the vestibular nucleus complex (VNC) ipsilateral to the lesion, which could potentially reduce commissural inhibition from the contralateral VNC. In this study, we tested the possibility that this occurs through a decrease in the expression of either the GABA(B1) or GABA(B2) subunits of the GABA(B) receptor. We used Western blotting to quantify the expression of these subunits in the VNC at 10 h and 50 h following unilateral vestibular deafferentation (UVD) or sham surgery in rats. We then used immunocytochemistry and stereological counting methods to estimate the number of neurons expressing these subunits in the MVN at 10 h and 2 weeks following UVD or sham surgery. Compared to sham controls, we found no significant changes in either the expression of the two GABA(B) receptor subunits in the VNC or in the number of MVN neurons expressing these GABA(B) receptor subunits post-UVD. These results suggest that GABA(B) receptor expression does not change substantially in the VNC during the process of vestibular compensation.

  10. Application of computer simulation in the stereology of materials

    Czech Academy of Sciences Publication Activity Database

    Saxl, Ivan; Ponížil, P.; Löflerová, M.

    2009-01-01

    Roč. 4, č. 2 (2009), s. 231-249 ISSN 1741-8410 R&D Projects: GA ČR GA201/06/0302 Grant - others:GA ČR(CZ) GA106/05/0550 Institutional research plan: CEZ:AV0Z10190503 Keywords : 3D computer simulation * fibre anisotropy * fracture surface * grain size estimation * random tessellation * rough surface analysis * fibre processes Subject RIV: BA - General Mathematics

  11. 49 CFR 192.243 - Nondestructive testing.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Nondestructive testing. 192.243 Section 192.243... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Welding of Steel in Pipelines § 192.243 Nondestructive testing. (a) Nondestructive testing of welds must be performed by any process, other than trepanning, that...

  12. Autogenous bone graft and ePTFE membrane in the treatment of peri-implantitis. II. Stereologic and histologic observations in cynomolgus monkeys

    DEFF Research Database (Denmark)

    Schou, Søren; Holmstrup, Palle; Skovgaard, Lene Theil

    2003-01-01

    autogenous bone graft; guided bone regeneration; histology; membrane; non-human primates; oral implants; osseointegration; pathalogy; peri-implantitis; stereology; treatment......autogenous bone graft; guided bone regeneration; histology; membrane; non-human primates; oral implants; osseointegration; pathalogy; peri-implantitis; stereology; treatment...

  13. Recent improvements concerning nondestructive testing

    International Nuclear Information System (INIS)

    Asty, M.

    1984-12-01

    Rare are the techniques of which development is not already touched by microelectronics and micro-data processing. Nondestructive testing and more particularly ultrasonic and Foucault current testing follow this general rule. With some examples, this paper focuses on the potential of numerical signal processing [fr

  14. Nondestructive testing at the CEA

    International Nuclear Information System (INIS)

    Colomer, J.; Lucas, G.

    1976-01-01

    The different nondestructive testing methods used at the CEA are presented: X-ray or gamma radiography, X-ray stress analysis, neutron radiography, ultrasonic testing, eddy currents, electrical testing, microwaves, thermal testing, acoustic emission, optical holography, tracer techniques. (102 references are cited) [fr

  15. Three-dimensional stereology as a tool for evaluating bladder outlet obstruction

    DEFF Research Database (Denmark)

    Wijk, J. Van der; Wijk, J. Van der; Horn, T.

    2008-01-01

    -cup biopsy, taken during cystoscopy, was stereologically evaluated to determine the smooth muscle cell volume and the fractions of collagen and smooth muscle using light and electron microscopy. Results. The collagen fraction was higher in patients than in controls (probably because the patients were older...... tract symptoms (LUTS) suggestive of BOO and five controls (mean age 48.6 years; range 43-53 years) without LUTS were studied. All participants underwent a full examination, including determination of the International Prostate Symptom Score, laboratory analysis and a urodynamic evaluation. A cold...

  16. Introducing Stereology as a Tool to Assess the Severity of Psoriasis

    DEFF Research Database (Denmark)

    Kamp, Søren; Stenderup, Karin; Rosada, Cecilia

    2008-01-01

    to histological specimens in order to obtain three-dimensional properties from two-dimensional tissue samples. The psoriasis xenograft model used in this trial is accepted as a leading animal model for psoriasis. Psoriatic skin from psoriatic patients was grafted onto severe combined immunodeficient (SCID) mice......  The purpose of this study was to introduce stereology as a novel tool in assessing the severity of psoriasis. Psoriasis is a well described chronic inflammatory skin disease affecting approximately 2% of the Caucasian population.   The severity of psoriasis has been assessed by a multitude...

  17. Stereological estimates of nuclear volume in squamous cell carcinoma of the uterine cervix and its precursors

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Bichel, P; Jakobsen, A

    1991-01-01

    -sampling of nuclear intercepts in 51 pre-treatment biopsies from patients with invasive squamous cell carcinomas (SCC). Vertical sections from 27 specimens with cervical intraepithelial neoplasia (CIN) grades I through III were also investigated, along with 10 CIN III associated with microinvasion (CIN III + M...

  18. Developments in non-destructive beam diagnostics

    International Nuclear Information System (INIS)

    Fraser, J.S.

    1981-01-01

    With the large average beam currents being achieved in accelerators and storage rings, there is an increasing need for non-destructive beam diagnostic devices. For continuous beams, position monitors of the capacitive pick-up type are replaced by resonant devices that respond to the transverse displacement of the beam centroid. Bunch length monitors of the SLAC type using resonant cavities operating in the TM 010 mode can be used for continuous beams. The more detailed information derivable from beam profile scanners requires development of improved non-destructive devices. Profile monitors which scan the visible light produced by high current beams may be more reliable than ones using the residual ionization if the light intensity from gas molecules following nonionizing collisions with beam particles gives a measure of the beam current density independent of the local electron density. The intense Balmer series lines from neutral hydrogen beams have been used successfully to measure beam profiles. At CRNL and at LASL, beam light profile monitors are being developed for high average current accelerators. Three or more projections will be recorded to allow tomographic reconstruction of the two-dimensional beam current density. Light detection is either by intensified Reticons or ISIT vidicons. The use of three or more beam light monitors on a beam transport line will also permit estimates of the transverse emittance to be made through the reconstruction technique

  19. Radiation control in the nondestructive inspection

    International Nuclear Information System (INIS)

    Kariya, Yukihiro

    1982-01-01

    In the early days of radiation nondestructive inspection about ten years ago, the loss of radiation sources and careless radiation exposure gave the impression of radiography inspection being immediately slipshod management. In this problem, the peculiar nature of the business in this field is involved. In Nondestructive Inspection Co., Ltd., besides the safety management of radioisotopes, the radiation exposure control of personnel in the regular inspection of nuclear power plants has become increasingly important. The following matters are described: radiation utilization in nondestructive inspection (X- and #betta#-ray radiography, #betta#-ray leak test on shield), radiation control problems in nondestructive inspection business (the peculiar aspects of the business, the analysis of the incidents related with nondestructive inspection), and the practice of radiation control in nondestructive inspection in Nondestructive Inspection Co., Ltd. (Mori, K.)

  20. Stereology of the thyroid gland in Indo-Pacific bottlenose dolphin (Tursiops aduncus in comparison with human (Homo sapiens: quantitative and functional implications.

    Directory of Open Access Journals (Sweden)

    Brian Chin Wing Kot

    Full Text Available The mammalian thyroid gland maintains basal metabolism in tissues for optimal function. Determining thyroid volume is important in assessing growth and involution. Volume estimation is also important in stereological studies. Direct measurements of colloid volume and nuclear-to-cytoplasmic ratio of the follicular cells may provide important information about thyroid gland function such as hormone storage and secretion, which helps understand the changes at morphological and functional levels. The present study determined the colloid volume using simple stereological principle and the nuclear-to-cytoplasmic ratio of 4 Indo-Pacific bottlenose dolphins and 2 human thyroid glands. In both dolphin and human thyroid glands, the size of the follicles tended to be quite variable. The distribution of large and small follicles within the thyroid gland was also found to be random in both the dolphin and human thyroid gland; however, the size of follicles appeared to decrease as a function of increasing age in the dolphin thyroid gland. The mean colloid volume of the dolphin thyroid gland and human thyroid gland was 1.22×10(5 µm(3 and 7.02×10(5 µm(3 respectively. The dolphin and human subjects had a significant difference in the mean colloid volume. The mean N/C ratio of the dolphin thyroid follicular epithelia and human follicular epithelia was 0.50 and 0.64 respectively. The dolphin and human subjects had a significant difference in the mean N/C ratio. This information contributes to understanding dolphin thyroid physiology and its structural adaptations to meet the physical demands of the aquatic environment, and aids with ultrasonography and corrective therapy in live subjects.

  1. Tensor-based morphometry and stereology reveal brain pathology in the complexin1 knockout mouse.

    Science.gov (United States)

    Kielar, Catherine; Sawiak, Stephen J; Navarro Negredo, Paloma; Tse, Desmond H Y; Morton, A Jennifer

    2012-01-01

    Complexins (Cplxs) are small, soluble, regulatory proteins that bind reversibly to the SNARE complex and modulate synaptic vesicle release. Cplx1 knockout mice (Cplx1(-/-)) have the earliest known onset of ataxia seen in a mouse model, although hitherto no histopathology has been described in these mice. Nevertheless, the profound neurological phenotype displayed by Cplx1(-/-) mutants suggests that significant functional abnormalities must be present in these animals. In this study, MRI was used to automatically detect regions where structural differences were not obvious when using a traditional histological approach. Tensor-based morphometry of Cplx1(-/-) mouse brains showed selective volume loss from the thalamus and cerebellum. Stereological analysis of Cplx1(-/-) and Cplx1(+/+) mice brain slices confirmed the volume loss in the thalamus as well as loss in some lobules of the cerebellum. Finally, stereology was used to show that there was loss of cerebellar granule cells in Cplx1(-/-) mice when compared to Cplx1(+/+) animals. Our study is the first to describe pathological changes in Cplx1(-/-) mouse brain. We suggest that the ataxia in Cplx1(-/-) mice is likely to be due to pathological changes in both cerebellum and thalamus. Reduced levels of Cplx proteins have been reported in brains of patients with neurodegenerative diseases. Therefore, understanding the effects of Cplx depletion in brains from Cplx1(-/-) mice may also shed light on the mechanisms underlying pathophysiology in disorders in which loss of Cplx1 occurs.

  2. Tensor-based morphometry and stereology reveal brain pathology in the complexin1 knockout mouse.

    Directory of Open Access Journals (Sweden)

    Catherine Kielar

    Full Text Available Complexins (Cplxs are small, soluble, regulatory proteins that bind reversibly to the SNARE complex and modulate synaptic vesicle release. Cplx1 knockout mice (Cplx1(-/- have the earliest known onset of ataxia seen in a mouse model, although hitherto no histopathology has been described in these mice. Nevertheless, the profound neurological phenotype displayed by Cplx1(-/- mutants suggests that significant functional abnormalities must be present in these animals. In this study, MRI was used to automatically detect regions where structural differences were not obvious when using a traditional histological approach. Tensor-based morphometry of Cplx1(-/- mouse brains showed selective volume loss from the thalamus and cerebellum. Stereological analysis of Cplx1(-/- and Cplx1(+/+ mice brain slices confirmed the volume loss in the thalamus as well as loss in some lobules of the cerebellum. Finally, stereology was used to show that there was loss of cerebellar granule cells in Cplx1(-/- mice when compared to Cplx1(+/+ animals. Our study is the first to describe pathological changes in Cplx1(-/- mouse brain. We suggest that the ataxia in Cplx1(-/- mice is likely to be due to pathological changes in both cerebellum and thalamus. Reduced levels of Cplx proteins have been reported in brains of patients with neurodegenerative diseases. Therefore, understanding the effects of Cplx depletion in brains from Cplx1(-/- mice may also shed light on the mechanisms underlying pathophysiology in disorders in which loss of Cplx1 occurs.

  3. Nondestructive testing of concrete structures

    International Nuclear Information System (INIS)

    Rufino, Randy R.; Relunia, Estrella

    1999-01-01

    Nondestructive testing of concrete is highly inhomogeneous which makes it cumbersome to setup experimental procedures and analyze experimental data. However, recent research and development activities have discovered the different methods of NDT, like the electromagnetic method, ultrasonic pulse velocity test, pulse echo/impact echo test, infrared thermography, radar or short pulse radar techniques, neutron and gamma radiometry, radiography, carbonation test and half-cell potential method available for NDT of concrete structures. NDT of concrete is emerging as a useful tool for quality control and assurance. This papers also describes the more common NDT methods discussed during the two-week course on 'Nondestructive Testing of Concrete Structures', held at the Malaysian Institute for Nuclear Technology Research (MINT) in Malaysia, which was jointly organized by MINT and the International Atomic Energy Agency (IAEA)

  4. Nondestructive assay of sale materials

    International Nuclear Information System (INIS)

    Rodenburg, W.W.; Fleissner, J.G.

    1981-01-01

    This paper covers three primary areas: (1) reasons for performing nondestructive assay on SALE materials; (2) techniques used; and (3) discussion of investigators' revised results. The study shows that nondestructive calorimetric assay of plutonium offers a viable alternative to traditional wet chemical techniques. For these samples, the precision ranged from 0.4 to 0.6% with biases less than 0.2%. Thus, for those materials where sampling errors are the predominant source of uncertainty, this technique can provide improved accuracy and precision while saving time and money as well as reducing the amount of liquid wastes to be handled. In addition, high resolution gamma-ray spectroscopy measurements of solids can provide isotopic analysis data in a cost effective and timely manner. The timeliness of the method can be especially useful to the plant operator for production control and quality control measurements

  5. European conference on nondestructive testing

    Energy Technology Data Exchange (ETDEWEB)

    Klyuev, V V

    1985-01-01

    Information on the 3-d European conference on nondestructive testing (NT) held in October, 1984 in Florence, is presented. Plenary reports were devoted to complex use of different NT methods, tendencies to NT automation and robotics, transition from defectoscopy to quality control, determination of phisico-mechanical properties of items using different control methods, formulation of unified international programs on professional training and qualification. Section reports cover the following directions: NT use in aviation and astronautics, construction, welding engineering, studying works of art; personnel training, economics, NT functioning, automation, calibration, standardization, quality control over metallic and nonmetallic objects. Some reports concerned nondestructive testing of items during their use. Attention is paied to radiographic testing and neutron radiography as well as to image processing. NT equipment was also discussed.

  6. Basic metallurgy for nondestructive testing

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    For this chapter, reader will be served with the basic knowledge on metallurgy for nondestructive testing. One the main application of nondestructive testing is to detect discontinuity of mass defect in metal. As we already know, metal are widely used in many application such as in building as a system, component and engineering product. Steel and iron are metal that usually used in industry, especially heavy industry such as gas and petroleum industry, chemistry, electric generation, automobile, and military device. Based on this, basic knowledge on metallurgy must need by NDT practitioner. The combination between metallurgy and datas from radiography testing can make radiographer good interpretation on quality of the metal inspected and can used to make a good decision either to accept or not certain product, system or components.

  7. Nondestructive inspection using neutron beams

    International Nuclear Information System (INIS)

    2013-01-01

    Neutron-abased experimental techniques such as neutronography, diffraction, or composition and elemental analysis are well established. They have important advantages in the non-destructive analysis of materials, making them a suitable option for quality-control protocols in industrial production lines. In addition, they are highly complementary to other non-destructive techniques, particularly X-ray analysis. Examples of industrial use include studies of pipes and ducts, concrete, or aeronautical components. Notwithstanding the above, the high cost associated with the construction and operation of the requisite neutron facilities has been an important limiting factor for their widespread use by the industrial sector. In this brief contribution, we explore the emerging (and already demonstrated) possibility of using compact, proton-accelerator-based neutron sources. these novel sources can be built and ran at a cost as low as a few ME, making them a competitive option to the more intense spallation or fission-based facilities for industrial applications. (Author)

  8. FIBRIN-TYPE FIBRINOID IN HUMAN PLACENTA: A STEREOLOGICAL ANALYSIS OF ITS ASSOCIATION WITH INTERVILLOUS VOLUME AND VILLOUS SURFACE AREA

    Directory of Open Access Journals (Sweden)

    Terry M Mayhew

    2011-05-01

    Full Text Available Stereological methods were used to examine fibrin-type fibrinoid deposition in the intervillous spaces of human placentas collected during gestation (12-41 weeks and from term pregnancies at low (400 m and high (3.6 km altitude. The main aim was to test predictions about the relationships between fibrinoid deposits and either the volume of intervillous space or the surface area of (intermediate + terminal villi. Fields of view on Masson trichrome-stained paraffin sections were selected as part of a systematic sampling design which randomised section location and orientation. Relative and absolute volumes were estimated by test point counting and surfaces by intersection counting. Apparent differences were tested by analyses of variance and relationships by correlation and regression analysis. Fibrinoid volume increased during gestation and correlated positively with intervillous volume and villous surface area. However, relative to intervillous volume, the main increase in fibrinoid occurred towards term (36-41 weeks. At high altitude, placentas contained more intervillous space but less fibrinoid. At both altitudes, there were significant correlations between fibrinoid volume and villous surface area. In all cases, changes in fibrinoid volume were commensurate with changes in villous surface area. Whilst findings lend support to the notion that fibrinoid deposition during normal gestation is influenced by the quality of vascular perfusion, they also emphasise that the extent of the villous surface is a more generally important factor. The villous surface may influence the steady state between coagulation and fibrinolysis since some pro-coagulatory events operate at the trophoblastic epithelium. They occur notably at sites of trophoblast de-epithelialisation and these arise following trauma or during the extrusion phase of normal epithelial turnover.

  9. The changes of stage distribution of seminiferous epithelium cycle and its correlations with Leydig cell stereological parameters in aging men.

    Science.gov (United States)

    Huang, Rui; Zhu, Wei-Jie; Li, Jing; Gu, Yi-Qun

    2014-12-01

    To evaluate the changes of stage distribution of seminiferous epithelium cycle and its correlations with Leydig cell stereological parameters in aging men. Point counting method was used to analyze the stereological parameters of Leydig cells. The stage number of seminiferous epithelium cycle was calculated in the same testicular tissue samples which were used for Leydig cell stereological analysis. The aging group had shown more severe pathological changes as well as higher pathologic scores than the young group. Compared with the control group, the volume density (VV) and surface density (NA) of Leydig cells in the aging group were increased significantly. The stage number of seminiferous epithelium cycle in the aging group was decreased coincidently compared to the young group. Leydig cell Vv in the young group has a positive relationship with stages I, II, III, V and VI of seminiferous epithelium cycle, and Leydig cell NA and numerical density (NV) were positively related to stage IV. However, only the correlation between NV and stage II was found in the aging group. The stage number of seminiferous epithelium cycle was decreased in aging testes. Changes in the stage distribution in aging testes were related to the Leydig cell stereological parameters which presented as a sign of morphological changes. Copyright © 2014 Elsevier GmbH. All rights reserved.

  10. Stereologic, histopathologic, flow cytometric, and clinical parameters in the prognostic evaluation of 74 patients with intraoral squamous cell carcinomas

    DEFF Research Database (Denmark)

    Bundgaard, T; Sørensen, Flemming Brandt; Gaihede, M

    1992-01-01

    BACKGROUND AND METHODS: A consecutive series of all 78 incident cases of intraoral squamous cell carcinoma occurring during a 2-year period in a population of 1.4 million inhabitants were evaluated by histologic score (the modified classification of Jacobsson et al.), flow cytometry, stereology, ...

  11. Aging management of major LWR components with nondestructive evaluation

    International Nuclear Information System (INIS)

    Shah, V.N.; MacDonald, P.E.; Akers, D.W.; Sellers, C.; Murty, K.L.; Miraglia, P.Q.; Mathew, M.D.; Haggag, F.M.

    1997-01-01

    Nondestructive evaluation of material damage can contribute to continued safe, reliable, and economical operation of nuclear power plants through their current and renewed license period. The aging mechanisms active in the major light water reactor components are radiation embrittlement, thermal aging, stress corrosion cracking, flow-accelerated corrosion, and fatigue, which reduce fracture toughness, structural strength, or fatigue resistance of the components and challenge structural integrity of the pressure boundary. This paper reviews four nondestructive evaluation methods with the potential for in situ assessment of damage caused by these mechanisms: stress-strain microprobe for determining mechanical properties of reactor pressure vessel and cast stainless materials, magnetic methods for estimating thermal aging damage in cast stainless steel, positron annihilation measurements for estimating early fatigue damage in reactor coolant system piping, and ultrasonic guided wave technique for detecting cracks and wall thinning in tubes and pipes and corrosion damage to embedded portion of metal containments

  12. The 30 Years of the Korean Society for Nondestructive Testing

    International Nuclear Information System (INIS)

    2010-05-01

    The contents of this book are development of nondestructive testings; the origin of nondestructive testing, history of Korea on nondestructive testing and present condition of nondestructive testing in Korea, history of society, activity of society; structure and activity of society, publication of society academic project, educational work, international exchange, and the future and direction of development of the Korean society for nondestructive testing.

  13. Non-Destructive Inspection Lab (NDI)

    Data.gov (United States)

    Federal Laboratory Consortium — The NDI specializes in applied research, development and performance of nondestructive inspection procedures (flourescent penetrant, magnetic particle, ultrasonics,...

  14. Nondestructive testing for bridge diagnosis

    International Nuclear Information System (INIS)

    Oshima, Toshiyuki; Mikami, Shuichi; Yamazaki, Tomoyuki

    1997-01-01

    There are many motivations for bridge diagnosis using Nondestructive testing (NDT) to monitor its integrity. The measured frequency and damping on real bridge are compared in one figure as a function of span length and general aspects are explained. These date were measured in every construction of bridges and applied to design new bridges. Ultrasonic testing is also well used for concrete and steel members mainly to detect internal damages or delaminations. Detail analysis on reflected waves gives us more accurate information about the defect. Experimental results are shown as examples in this paper.

  15. Nondestructive analysis of irradiated fuels

    International Nuclear Information System (INIS)

    Dudey, N.D.; Frick, D.C.

    1977-01-01

    The principal nondestructive examination techniques presently used to assess the physical integrity of reactor fuels and cladding materials include gamma-scanning, profilometry, eddy current, visual inspection, rod-to-rod spacing, and neutron radiography. LWR fuels are generally examined during annual refueling outages, and are conducted underwater in the spent fuel pool. FBR fuels are primarily examined in hot cells after fuel discharge. Although the NDE techniques are identical, LWR fuel examinations emphasize tests to demonstrate adherence to technical specification and reliable fuel performance; whereas, FBR fuel examinations emphasize aspects more related to the relative performance of different types of fuel and cladding materials subjected to variable irradiation conditions

  16. Stereological observations of platelet-reinforced mullite- and zirconia-matrix composites

    International Nuclear Information System (INIS)

    Cherian, I.K.; Kriven, W.M.; Lehigh, M.D.; Nettleship, I.

    1996-01-01

    Recently, the effect of solid inclusions on the sintering of ceramic powders has been explained in terms of a back-stress that opposes densification. Several analyses have been proposed to describe this problem. However, little quantitative information exists concerning the effect of reinforcement on microstructural evolution. This study compares the microstructural development of zirconia and mullite matrices in the presence of alumina platelets. The effect of platelet loading on density is similar for both composites. Quantitative stereological examinations reveal that the average grain size and pore size are finer for the zirconia-matrix composite. The platelet loading does not have any noticeable effect on the average grain size of the matrix in either composite. However, the average pore size increases as the volume fraction of platelets increases for both materials. Contiguity measurements have detected some aggregation of platelets in the zirconia-matrix composite

  17. Three-dimensional stereology as a tool for evaluating bladder outlet obstruction

    DEFF Research Database (Denmark)

    Van Der Wijk, Jasper; Van Der Wijk, Jan; Horn, Thomas

    2008-01-01

    Objective. In a pilot study we evaluated whether implementation of a novel 3D stereologic technique can prove that bladder outlet obstruction (BOO) is associated with morphologic changes in the bladder wall. Material and methods. Ten males (mean age 69.7 years; range 58-84 years) with lower urinary...... tract symptoms (LUTS) suggestive of BOO and five controls (mean age 48.6 years; range 43-53 years) without LUTS were studied. All participants underwent a full examination, including determination of the International Prostate Symptom Score, laboratory analysis and a urodynamic evaluation. A cold....... Conclusions. This pilot study shows that, even with the implementation of subtle morphometric techniques, there seems to be no relationship between the severity of BOO and bladder wall morphology. It is possible that interstitial collagen in the bladder wall increases with age. It seems that bladder wall...

  18. Stereological quantification of immune-competent cells in baseline biopsy specimens from achilles tendons

    DEFF Research Database (Denmark)

    Kragsnaes, Maja Skov; Fredberg, Ulrich; Stribolt, Katrine

    2014-01-01

    BACKGROUND: Limited data exist on the presence and function of immune-competent cells in chronic tendinopathic tendons and their potential role in inflammation and tissue healing as well as in predicting long-term outcome. PURPOSE: To quantify subtypes of immune-competent cells in biopsy specimens...... immunohistochemically by quantifying the presence of macrophages (CD68-PGM1(+), CD68-KP1(+)), hemosiderophages (Perls blue), T lymphocytes (CD2(+), CD3(+), CD4(+), CD7(+), CD8(+)), B lymphocytes (CD20(+)), natural killer cells (CD56(+)), mast cells (NaSDCl(+)), Schwann cells (S100(+)), and endothelial cells (CD34......(+)) using a stereological technique. A follow-up examination was conducted more than 4 years (range, 4-9 years) after the biopsy procedure to evaluate the long-term presence of Achilles tendon symptoms. RESULTS: Macrophages, T lymphocytes, mast cells, and natural killer cells were observed in the majority...

  19. A Stereological Method for the Quantitative Evaluation of Cartilage Repair Tissue

    Science.gov (United States)

    Nyengaard, Jens Randel; Lind, Martin; Spector, Myron

    2015-01-01

    Objective To implement stereological principles to develop an easy applicable algorithm for unbiased and quantitative evaluation of cartilage repair. Design Design-unbiased sampling was performed by systematically sectioning the defect perpendicular to the joint surface in parallel planes providing 7 to 10 hematoxylin–eosin stained histological sections. Counting windows were systematically selected and converted into image files (40-50 per defect). The quantification was performed by two-step point counting: (1) calculation of defect volume and (2) quantitative analysis of tissue composition. Step 2 was performed by assigning each point to one of the following categories based on validated and easy distinguishable morphological characteristics: (1) hyaline cartilage (rounded cells in lacunae in hyaline matrix), (2) fibrocartilage (rounded cells in lacunae in fibrous matrix), (3) fibrous tissue (elongated cells in fibrous tissue), (4) bone, (5) scaffold material, and (6) others. The ability to discriminate between the tissue types was determined using conventional or polarized light microscopy, and the interobserver variability was evaluated. Results We describe the application of the stereological method. In the example, we assessed the defect repair tissue volume to be 4.4 mm3 (CE = 0.01). The tissue fractions were subsequently evaluated. Polarized light illumination of the slides improved discrimination between hyaline cartilage and fibrocartilage and increased the interobserver agreement compared with conventional transmitted light. Conclusion We have applied a design-unbiased method for quantitative evaluation of cartilage repair, and we propose this algorithm as a natural supplement to existing descriptive semiquantitative scoring systems. We also propose that polarized light is effective for discrimination between hyaline cartilage and fibrocartilage. PMID:26069715

  20. Estimation of the proportion of some elements and their distribution on a surface of thallus of lichenized fungus Xanthoria parietina (L. Th. Fr. using sample-nondestructive μ-XRF spectrometer M4 Tornado

    Directory of Open Access Journals (Sweden)

    Biazrov Lev Georgievich

    2013-10-01

    Full Text Available The composition of 19 elements - Al, Si, P, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Sr, Ba, Pb - were compared in the peripheral (younger and central (older parts of the upper surface of the epiphytic lichen Xanthoria parietina thallus from the bark of Sorbus aucuparia in Moscow city using sample-nondestructive μ-XRF spectrometer. This species is often used in biomonitoring of air quality. The results showed that the elements content was highly variable. Mean values of atomic percent of Fe, Co, Zn, and Pb were statistically higher in the central part of the upper surface, while P, S, Cl, K, Ca, and Mn were higher in the peripheral part. Differences between other elements were not statistically valid, but there is a trend to greater maintenance of the majority of the elements on the surface of the central part of the thallus. Mapping the distribution of some elements on the part of the thallus surface is presented.

  1. Total numbers of neurons and glial cells in cortex and basal ganglia of aged brains with Down syndrome--a stereological study.

    Science.gov (United States)

    Karlsen, Anna Schou; Pakkenberg, Bente

    2011-11-01

    The total numbers of neurons and glial cells in the neocortex and basal ganglia in adults with Down syndrome (DS) were estimated with design-based stereological methods, providing quantitative data on brains affected by delayed development and accelerated aging. Cell numbers, volume of regions, and densities of neurons and glial cell subtypes were estimated in brains from 4 female DS subjects (mean age 66 years) and 6 female controls (mean age 70 years). The DS subjects were estimated to have about 40% fewer neocortical neurons in total (11.1 × 10(9) vs. 17.8 × 10(9), 2p ≤ 0.001) and almost 30% fewer neocortical glial cells with no overlap to controls (12.8 × 10(9) vs. 18.2 × 10(9), 2p = 0.004). In contrast, the total number of neurons in the basal ganglia was the same in the 2 groups, whereas the number of oligodendrocytes in the basal ganglia was reduced by almost 50% in DS (405 × 10(6) vs. 816 × 10(6), 2p = 0.01). We conclude that trisomy 21 affects cortical structures more than central gray matter emphasizing the differential impairment of brain development. Despite concomitant Alzheimer-like pathology, the neurodegenerative outcome in a DS brain deviates from common Alzheimer disease.

  2. Educational ultrasound nondestructive testing laboratory.

    Science.gov (United States)

    Genis, Vladimir; Zagorski, Michael

    2008-09-01

    The ultrasound nondestructive evaluation (NDE) of materials course was developed for applied engineering technology students at Drexel University's Goodwin College of Professional Studies. This three-credit, hands-on laboratory course consists of two parts: the first part with an emphasis on the foundations of NDE, and the second part during which ultrasound NDE techniques are utilized in the evaluation of parts and materials. NDE applications are presented and applied through real-life problems, including calibration and use of the latest ultrasonic testing instrumentation. The students learn engineering and physical principles of measurements of sound velocity in different materials, attenuation coefficients, material thickness, and location and dimensions of discontinuities in various materials, such as holes, cracks, and flaws. The work in the laboratory enhances the fundamentals taught during classroom sessions. This course will ultimately result in improvements in the educational process ["The greater expectations," national panel report, http://www.greaterexpectations.org (last viewed February, 2008); R. M. Felder and R. Brent "The intellectual development of Science and Engineering Students. Part 2: Teaching to promote growth," J. Eng. Educ. 93, 279-291 (2004)] since industry is becoming increasingly reliant on the effective application of NDE technology and the demand on NDE specialists is increasing. NDE curriculum was designed to fulfill levels I and II NDE in theory and training requirements, according to American Society for Nondestructive Testing, OH, Recommended Practice No. SNT-TC-1A (2006).

  3. Active spectral imaging nondestructive evaluation (SINDE) camera

    Energy Technology Data Exchange (ETDEWEB)

    Simova, E.; Rochefort, P.A., E-mail: eli.simova@cnl.ca [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada)

    2016-06-15

    A proof-of-concept video camera for active spectral imaging nondestructive evaluation has been demonstrated. An active multispectral imaging technique has been implemented in the visible and near infrared by using light emitting diodes with wavelengths spanning from 400 to 970 nm. This shows how the camera can be used in nondestructive evaluation to inspect surfaces and spectrally identify materials and corrosion. (author)

  4. Non-destructive testing at Chalk River

    International Nuclear Information System (INIS)

    Hilborn, J.W.

    1976-01-01

    In 1969 CRNL recognized the need for a strong group skilled in non-destructive test procedures. Within two years a new branch called Quality Control Branch was staffed and working. This branch engages in all aspects of non-destructive testing including development of new techniques, new applications of known technology, and special problems in support of operating reactors. (author)

  5. Nondestructive analysis of sugar content on watermelon using MRI device

    International Nuclear Information System (INIS)

    Miki, Takashi; Saito, Kazuyoshi; Hayashi, Seiji

    1996-01-01

    So far, the use of superconducting magnets has been limited to chemical analysis and medical inspection. To develop a new use, we have tried to apply common MRI devices as nondestructive sugar content detector of watermelon. To estimate the sugar content, a new technique using multiple regression analysis of two NMR relaxation times was developed. It was found that the coefficient of multiple regression at the center of the watermelon exceeded 0.9 and the standard error of prediction was around 0.5, and that the over-ripened part of flesh called 'nieka' in watermelon could be distinguished because its T 2 was much longer than that of the ordinary part. An evaluation rate of sugar content could be below 6s per watermelon. It is concluded that multiple analysis of T 1 and T 2 on intact watermelon can be applied as a noninvasive, nondestructive indicator of sugar content. (author)

  6. Can non-destructive inspection be reliable

    International Nuclear Information System (INIS)

    Silk, M.G.; Stoneham, A.M.; Temple, J.A.G.

    1988-01-01

    The paper on inspection is based on the book ''The reliability of non-destructive inspection: assessing the assessment of structures under stress'' by the present authors (published by Adam Hilger 1987). Emphasis is placed on the reliability of inspection and whether cracks in welds or flaws in components can be detected. The need for non-destructive testing and the historical attitudes to non-destructive testing are outlined, along with the case of failure. Factors influencing reliable inspection are discussed, and defect detection trials involving round robin tests are described. The development of reliable inspection techniques and the costs of reliability and unreliability are also examined. (U.K.)

  7. Nondestructive assay measurements applied to reprocessing plants

    International Nuclear Information System (INIS)

    Ruhter, Wayne D.; Lee, R. Stephen; Ottmar, Herbert; Guardini, Sergio

    1999-01-01

    Nondestructive assay for reprocessing plants relies on passive gamma-ray spectrometry for plutonium isotopic and plutonium mass values of medium-to-low-density samples and holdup deposits; on active x-ray fluorescence and densitometry techniques for uranium and plutonium concentrations in solutions; on calorimetry for plutonium mass in product; and passive neutron techniques for plutonium mass in spent fuel, product, and waste. This paper will describe the radiation-based nondestructive assay techniques used to perform materials accounting measurements. The paper will also discuss nondestructive assay measurements used in inspections of reprocessing plants [ru

  8. The Effects of Acoustic White Noise on the Rat Central Auditory System During the Fetal and Critical Neonatal Periods: A Stereological Study.

    Science.gov (United States)

    Salehi, Mohammad Saied; Namavar, Mohammad Reza; Tamadon, Amin; Bahmani, Raziyeh; Jafarzadeh Shirazi, Mohammad Reza; Khazali, Homayoun; Dargahi, Leila; Pandamooz, Sareh; Mohammad-Rezazadeh, Farzad; Rashidi, Fatemeh Sadat

    2017-01-01

    To evaluate the effects of long-term, moderate level noise exposure during crucial periods of rat infants on stereological parameters of medial geniculate body (MGB) and auditory cortex. Twenty-four male offspring of 12 pregnant rats were divided into four groups: fetal-to-critical period group, which were exposed to noise from the last 10 days of fetal life till postnatal day (PND) 29; fetal period group that exposed to noise during the last 10 days of fetal life; critical period group, exposed to noise from PND 15 till PND 29, and control group. White noise at 90 dB for 2 h per day was used. Variance for variables was performed using Proc GLM followed by mean comparison by Duncan's multiple range test. Numerical density of neurons in MGB of fetal-to-critical period group was lower than control group. Similar results were seen in numerical density of neurons in layers IV and VI of auditory cortex. Furthermore, no significant difference was observed in the volume of auditory cortex among groups, and only MGB volume in fetal-to-critical period group was higher than other groups. Estimated total number of neurons in MGB was not significantly different among groups. It seems necessary to prevent long-term moderate level noise exposure during fetal-to-critical neonatal period.

  9. Tutoring system for nondestructive testing using computer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Koo; Koh, Sung Nam [Joong Ang Inspection Co.,Ltd., Seoul (Korea, Republic of); Shim, Yun Ju; Kim, Min Koo [Dept. of Computer Engineering, Aju University, Suwon (Korea, Republic of)

    1997-10-15

    This paper is written to introduce a multimedia tutoring system for nondestructive testing using personal computer. Nondestructive testing, one of the chief methods for inspecting welds and many other components, is very difficult for the NDT inspectors to understand its technical basis without a wide experience. And it is necessary for considerable repeated education and training for keeping their knowledge. The tutoring system that can simulate NDT works is suggested to solve the above problem based on reasonable condition. The tutoring system shows basic theories of nondestructive testing in a book-style with video images and hyper-links, and it offers practices, in which users can simulate the testing equipment. The book-style and simulation practices provide effective and individual environments for learning nondestructive testing.

  10. Tutoring system for nondestructive testing using computer

    International Nuclear Information System (INIS)

    Kim, Jin Koo; Koh, Sung Nam; Shim, Yun Ju; Kim, Min Koo

    1997-01-01

    This paper is written to introduce a multimedia tutoring system for nondestructive testing using personal computer. Nondestructive testing, one of the chief methods for inspecting welds and many other components, is very difficult for the NDT inspectors to understand its technical basis without a wide experience. And it is necessary for considerable repeated education and training for keeping their knowledge. The tutoring system that can simulate NDT works is suggested to solve the above problem based on reasonable condition. The tutoring system shows basic theories of nondestructive testing in a book-style with video images and hyper-links, and it offers practices, in which users can simulate the testing equipment. The book-style and simulation practices provide effective and individual environments for learning nondestructive testing.

  11. Crataegus Monogyna Aqueous Extract Ameliorates Cyclophosphamide-Induced Toxicity in Rat Testis: Stereological Evidences

    Directory of Open Access Journals (Sweden)

    Hassan Malekinejad

    2012-01-01

    Full Text Available Cyclophosphamide (CP is extensively used as an antineoplastic agent for the treatment of various cancers, as well as an immunosuppressive agent. However, despite its wide spectrum of clinical uses, CP is known to cause several adverse effects including reproductive toxicity. Crataegus monogyna is one of the oldest pharmaceutical plants that have been shown to be cytoprotective by scavenging free radicals. The present study was conducted to assess whether Crataegus monogyna fruits aqueous extract with anti-oxidant properties, could serve as a protective agent against reproductive toxicity during CP treatment in a rat model. Male Wistar rats were categorized into four groups. Two groups of rats were administered CP at a dose of 5 mg in 5 ml saline/kg/day for 28 days by oral gavages. One of these groups received Crataegus monogyna aqueous extract at a dose of 20 mg/kg/day orally four hours after cyclophosphamide administration. A vehicle treated control group and a Crataegus monogyna control group were also included. The CP-treated group showed significant decreases in the body, testes and epididymides weights as well as many histological alterations. Stereological parameters and spermatogenic activities (Sertoli cell, repopulation and miotic indices were also significantly decreased by CP treatment. Notably, Crataegus coadministration caused a partial recovery in above-mentined parameters. These findings indicate that Crataegus monogyna may be partially protective against CP-induced testicular toxicity.

  12. A characteristic ventricular shape in myelomeningocele-associated hydrocephalus? A CT stereology study

    International Nuclear Information System (INIS)

    Roost, D. van; Solymosi, L.; Funke, K.

    1995-01-01

    We measured the volume of the supratentorial ventricles in 39 consecutive children with myelomeningocele (MMC) and associated hydrocephalus, using a stereological method based on the Cavalieri theorem of systematic sampling. We distinguished the following groups: newborns before and after cerebrospinal fluid shunting (14), a somewhat larger group of newborns with an untreated MMC-associated hydrocephalus (25) and a group of shunted children at a mean age of 1.5 years (28). We paid special attention to the shape of the lateral ventricles, looking separately at the anterior and posterior halves. The measurements were compared with a healthy control group (10) and with children with hydrocephalus unrelated to MMC (15). The average volume ratio of the posterior to the anterior half of the lateral ventricles was 1.05 ± 0.39 in non-hydrocephalic children, 1.11 ± 0.55 in untreated hydrocephalic children without MMC, and 2.15 ± 0.65 in MMC-associated hydrocephalus prior to shunting. These ratios did not change significantly after shunting. This confirms our impression that MMC-associated hydrocephalus shows a characteristic shape, with a disproportionate enlargement of the posterior part of the lateral ventricles, in clear contrast to the normal-width frontal horns. This shape is reminiscent of the fetal ventricular shape. It reveals disturbance of brain development in children with MMC, which goes beyond the classic description of the Chiari malformation. (orig.)

  13. Proliferation of Sertoli cells during development of the human testis assessed by stereological methods

    DEFF Research Database (Denmark)

    Cortes, D; Müller, J; Skakkebaek, N E

    1987-01-01

    Sertoli cells were studied using stereological methods in testes obtained from five children who were stillborn, and 31 individuals between 3 months and 40 years of age, who had suffered from sudden, unexpected death. The mean nuclear volume of the Sertoli cells, the numerical density of Sertoli...... cells, and the total number of Sertoli cells per individual were determined by point- and profile-counting of 0.5 micron sections. The nuclear volume of Sertoli cells increased from a median of 120 microns3 (range 53-130) during the period of 3 months to 10 years to 210 microns3 (170-260) in adults...... (greater than 25 years). The numerical density of Sertoli cells decreased from a median of 1200 X 10(6)/cm3 (870-1400) during childhood (3 months to 10 years) to 140 X 10(6)/cm3 (110-260) in adults (greater than 25 years). The total number of Sertoli cells per individual increased significantly from...

  14. FIRST USE OF STEREOLOGY TO QUANTIFY THE SURVIVAL OF FAT AUTOGRAFTS

    Directory of Open Access Journals (Sweden)

    Eduardo Serna Cuéllar

    2011-05-01

    Full Text Available It is not usual to perform quantitative analyses on surgical materials. Rather, they are evaluated clinically, through qualitative methods, and if quantitation is done, it is on a 2-dimensional basis. In this study, the long-term survival of fat autografts (FAG in 40 subjects with facial soft tissue defects is quantified. An adipose tissue preparation from the abdomen obtained through liposuction and centrifugation is injected subcutaneously. Approximately 14 months later, the treated area is biopsied. Extensive computer-based histological analyses were performed using the stereological method in order to directly obtain three parameters: volume fraction of adipocytes in the fat tissue (VV, density (number per volume of adipocytes in the fat tissue (NV, and the mean cell volume of adipocytes (VA in each tissue sample. A set of equations based on these three quantitative parameters is produced for evaluation of the volumetric survival fraction (VSF of FAG. The presented data evidenced a 66% survival fraction at the 14-month follow-up. In routine practice, it would be sufficient to perform this volumetric analysis on the injected and biopsied fat samples to know what fraction of the FAG has survived. This is an objective method for quantifying FAG survival and will allow a standardized comparison between different research series and authors.

  15. AUTOMATIC ESTIMATION OF SIZE PARAMETERS USING VERIFIED COMPUTERIZED STEREOANALYSIS

    Directory of Open Access Journals (Sweden)

    Peter R Mouton

    2011-05-01

    Full Text Available State-of-the-art computerized stereology systems combine high-resolution video microscopy and hardwaresoftware integration with stereological methods to assist users in quantifying multidimensional parameters of importance to biomedical research, including volume, surface area, length, number, their variation and spatial distribution. The requirement for constant interactions between a trained, non-expert user and the targeted features of interest currently limits the throughput efficiency of these systems. To address this issue we developed a novel approach for automatic stereological analysis of 2-D images, Verified Computerized Stereoanalysis (VCS. The VCS approach minimizes the need for user interactions with high contrast [high signal-to-noise ratio (S:N] biological objects of interest. Performance testing of the VCS approach confirmed dramatic increases in the efficiency of total object volume (size estimation, without a loss of accuracy or precision compared to conventional computerized stereology. The broad application of high efficiency VCS to high-contrast biological objects on tissue sections could reduce labor costs, enhance hypothesis testing, and accelerate the progress of biomedical research focused on improvements in health and the management of disease.

  16. Using the Optical Fractionator to Estimate Total Cell Numbers in the Normal and Abnormal Developing Human Forebrain

    DEFF Research Database (Denmark)

    Larsen, Karen B

    2017-01-01

    abnormal development. Furthermore, many studies of brain cell numbers have employed biased counting methods, whereas innovations in stereology during the past 20-30 years enable reliable and efficient estimates of cell numbers. However, estimates of cell volumes and densities in fetal brain samples...

  17. Surface tensor estimation from linear sections

    DEFF Research Database (Denmark)

    Kousholt, Astrid; Kiderlen, Markus; Hug, Daniel

    From Crofton's formula for Minkowski tensors we derive stereological estimators of translation invariant surface tensors of convex bodies in the n-dimensional Euclidean space. The estimators are based on one-dimensional linear sections. In a design based setting we suggest three types of estimators....... These are based on isotropic uniform random lines, vertical sections, and non-isotropic random lines, respectively. Further, we derive estimators of the specific surface tensors associated with a stationary process of convex particles in the model based setting....

  18. Surface tensor estimation from linear sections

    DEFF Research Database (Denmark)

    Kousholt, Astrid; Kiderlen, Markus; Hug, Daniel

    2015-01-01

    From Crofton’s formula for Minkowski tensors we derive stereological estimators of translation invariant surface tensors of convex bodies in the n-dimensional Euclidean space. The estimators are based on one-dimensional linear sections. In a design based setting we suggest three types of estimators....... These are based on isotropic uniform random lines, vertical sections, and non-isotropic random lines, respectively. Further, we derive estimators of the specific surface tensors associated with a stationary process of convex particles in the model based setting....

  19. Métodos não destrutivos para estimativa de densidade de área foliar em mangueira Non-destructive methods for estimating leaf area density in mango

    Directory of Open Access Journals (Sweden)

    Mario Zortéa Antunes Junior

    2009-12-01

    Full Text Available O objetivo deste trabalho foi estimar o número de folhas de ramos do dossel de cultivares de mangueira e estimar a densidade de área foliar utilizando, respectivamente, uma relação alométrica e um modelo de interceptação de luz. O trabalho foi conduzido com as cultivares Alfa, Roxa e Malind, na fazenda experimental da Universidade Federal de Mato Grosso, no Município de Santo Antônio do Leverger, MT. As equações testadas para a determinação do número de folhas apresentaram desempenho ótimo, com índices de confiança que variaram entre 0,85 e 0,94, e podem ser utilizadas como alternativa para a estimativa da área foliar das três cultivares. O modelo de interceptação da luz também apresentou desempenho ótimo e bom na estimativa da densidade foliar, com índices de confiança que variaram entre 0,97 e 0,99 e 0,68 e 0,95 para as cultivares de mangueira Roxa e Malind, respectivamente.The objective of this work was to estimate the number of leaves in the branches of mango cultivars canopies and to estimate the leaf area density using, respectively, an allometric relation and a light interception model. The work was carried out with the Alfa, Roxa and Malind cultivars, grown at the experimental farm of the Universidade Federal de Mato Grosso, in the municipality of Santo Antônio do Leverger, MT, Brazil. The equations tested for determining the number of leaves had excellent performance, with confidence indexes ranging from 0,85 to 0,94, and can be used as an alternative for estimating the leaf area of the three cultivars. The light interception model also had good performance in estimating leaf density, with confidence indexes ranging from 0,97 to 0,99 and from 0,68 to 0,95 for the Roxa and Malind mango cultivars respectively.

  20. Nondestructive Characterization of Aged Components

    Energy Technology Data Exchange (ETDEWEB)

    Panetta, Paul D.; Toloczko, Mychailo B.; Garner, Francis A.; Balachov, Iouri I.

    2003-10-21

    may be used for material properties measurements. A more appealing solution is to use nondestructive evaluation (NDE) methods.

  1. Proceedings for the nondestructive assay and nondestructive examination waste characterization conference. No. 5

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-05-01

    This report contains paper presented at the 5th Nondestructive Assay and nondestructive Examination Waste Characterization conference. Topics included compliance, neutron NDA techniques, gamma NDA techniques, tomographic methods, and NDA modality and information combination techniques. Individual reports have been processed separately for the United States Department of Energy databases.

  2. Proceedings for the nondestructive assay and nondestructive examination waste characterization conference. No. 5

    International Nuclear Information System (INIS)

    1997-01-01

    This report contains paper presented at the 5th Nondestructive Assay and nondestructive Examination Waste Characterization conference. Topics included compliance, neutron NDA techniques, gamma NDA techniques, tomographic methods, and NDA modality and information combination techniques. Individual reports have been processed separately for the United States Department of Energy databases

  3. Estimates of nuclear volume in plaque and tumor-stage mycosis fungoides. A new prognostic indicator

    DEFF Research Database (Denmark)

    Brooks, B; Sørensen, Flemming Brandt; Thestrup-Pedersen, K

    1994-01-01

    It is well documented that mycosis fungoides (MF), a cutaneous T-cell lymphoma, has a variable clinical course. Unbiased stereological estimates of three-dimensional volume-weighted mean nuclear size (nucl vV) of mycosis cells were obtained in a retrospective study of 18 patients with a total of ...

  4. Design-based estimation of neuronal number and individual neuronal volume in the rat hippocampus

    DEFF Research Database (Denmark)

    Hosseini-Sharifabad, Mohammad; Nyengaard, Jens Randel

    2007-01-01

    Tools recently developed in stereology were employed for unbiased estimation of the neuronal number and volume in three major subdivisions of rat hippocampus (dentate granular, CA1 and CA3 pyramidal layers). The optical fractionator is used extensively in quantitative studies of the hippocampus; ...

  5. Classification of tubulo-papillary renal cortical tumours using estimates of nuclear volume

    DEFF Research Database (Denmark)

    Brooks, B; Sørensen, Flemming Brandt; Olsen, S

    1993-01-01

    The classification of renal cortical tumours is problematic, with no clear division of benign from malignant tumours. Unbiased stereological estimates of volume-weighted nuclear volume (nuclear vv) were obtained by point sampling of nuclear intercepts in a retrospective study of 36 variably sized...

  6. Evaluation of FITC-induced atopic dermatitis-like disease in NC/Nga mice and BALB/c mice using computer-assisted stereological toolbox, a computer-aided morphometric system

    DEFF Research Database (Denmark)

    Hvid, Malene; Jensen, Helene Kofoed; Deleuran, Bent

    2009-01-01

    Stereological Toolbox as a stereological method, the mice were sensitized to FITC and the histological efficiency of disease induction with regard to inflammation and CD4+ and CD8+ lymphocytes, in addition to mast cells, was evaluated. The method was validated by comparison to a conventional semiquantitative...

  7. Effect of praziquantel administration on hepatic stereology of mice infected with Schistosoma mansoni and fed a low-protein diet

    Directory of Open Access Journals (Sweden)

    L.A. Barros

    2009-09-01

    Full Text Available A study was undertaken to investigate the effect of administering praziquantel (PZQ, focusing on the liver stereological findings of malnourished mice infected with Schistosoma mansoni. Thirty female Swiss Webster mice (age: 21 days; weight: 8-14 g were fed either a low-protein diet (8% or standard chow (22% protein for 15 days. Five mice in each group were infected with 50 cercariae each of the BH strain (Brazil. PZQ therapy (80 mg/kg body weight, per day was started on the 50th day of infection and consisted of daily administration for 5 days. Volume density (hepatocytes, sinusoids and hepatic fibrosis was determined by stereology using a light microscope. Body weight gain and total serum albumin levels were always lower in undernourished mice. Our stereological study demonstrated that treatment increased both volume density of hepatocytes in mice fed standard chow (47.56%, treated group and 12.06%, control and low-protein chow (30.98%, treated group and 21.44%, control, and hepatic sinusoids [standard chow (12.52%, treated group and 9.06%, control, low-protein chow (14.42%, treated group and 8.46%, control], while hepatic fibrosis was reduced [standard chow (39.92%, treated group and 78.88%, control and low-protein chow (54.60%, treated group and 70.10%, control]. On the other hand, mice fed low-protein chow decreased density volume of hepatocytes and hepatic fibrosis. In conclusion, our findings indicate that treatment with PZQ ameliorates hepatic schistosomiasis pathology even in mice fed a low-protein diet.

  8. On semiautomatic estimation of surface area

    DEFF Research Database (Denmark)

    Dvorak, J.; Jensen, Eva B. Vedel

    2013-01-01

    and the surfactor. For ellipsoidal particles, it is shown that the flower estimator is equal to the pivotal estimator based on support function measurements along four perpendicular rays. This result makes the pivotal estimator a powerful approximation to the flower estimator. In a simulation study of prolate....... If the segmentation is correct the estimate is computed automatically, otherwise the expert performs the necessary measurements manually. In case of convex particles we suggest to base the semiautomatic estimation on the so-called flower estimator, a new local stereological estimator of particle surface area....... For convex particles, the estimator is equal to four times the area of the support set (flower set) of the particle transect. We study the statistical properties of the flower estimator and compare its performance to that of two discretizations of the flower estimator, namely the pivotal estimator...

  9. Combining data in non-destructive testing

    International Nuclear Information System (INIS)

    Lavayssiere, B.

    1994-03-01

    Non-destructive testing of some components requires quite often the use of several methods such as X-ray, ultrasonics, Eddy Currents. But the efficiency of a NDT method is highly dependent on the fact that the detectability of flaws in a specimen relies on the choice of the best method. Moreover a lot of inspection issues could benefit from the use of more than one test method, as each NDT method has its own physical properties and technological limits. Some questions still remain: how to combine data, at what level and for what functionality. Simple monomethod processes are well-known now. They include techniques like reconstruction which belongs to the so-called ill-posed problems in the field of mathematics. For NDT data processing, it has the ability to estimate real data from distorted ones coming from a probe. But, up to now there has been very few approaches for computer aided combination of results from different advanced techniques. This report presents the various mathematical fields involved towards that goal (statistical decision theory which allows the use of multiple hypothesis, non-linear decision theory for its capability to classify and to discriminate, graph theory to find the optimal path in an hypothesis graph and also fuzzy logic, multiple resolution analysis, artificial intelligence,...) and which combinations of methods are useful. Some images will illustrate this topic in which EDF is involved, and will explain what are the major goals of this work. Combining is not only an improvement of 3D visualisation which would allow to display simultaneously CAD or NDT data for example, but it consists in exploiting multisensor data collected via a variety of sophisticated techniques and presenting this information to the operator without overloading the operator/system capacities in order to reduce the uncertainty and to resolve the ambiguity inherent to mono method inspection. (author). 7 figs., 35 refs

  10. Stereologic, histopathologic, flow cytometric, and clinical parameters in the prognostic evaluation of 74 patients with intraoral squamous cell carcinomas

    DEFF Research Database (Denmark)

    Bundgaard, T; Sørensen, Flemming Brandt; Gaihede, M

    1992-01-01

    , tumor size, and the TNM classification. RESULTS: The investigation showed a significant difference between the volume-weighted mean nuclear volume (nuclear vv) of oral leukoplakia (n = 29) and oral squamous cell carcinomas (P = 0.001). The value of the parameters as prognostic indicators of survival......BACKGROUND AND METHODS: A consecutive series of all 78 incident cases of intraoral squamous cell carcinoma occurring during a 2-year period in a population of 1.4 million inhabitants were evaluated by histologic score (the modified classification of Jacobsson et al.), flow cytometry, stereology...

  11. Nondestructive evaluation of potential quality of creosote-treated piles removed from service

    Science.gov (United States)

    Xiping. Wang; Robert J. Ross; John R. Erickson; John W. Forsman; Gary D. McGinnis; Rodney C. De Groot

    2001-01-01

    Stress-wave-based nondestructive evaluation methods were used to evaluate the potential quality and modulus of elasticity (MOE) of wood from creosote-treated Douglas-fir and southern pine piles removed from service. Stress-wave measurements were conducted on each pile section. Stress-wave propagation speeds were obtained to estimate the MOE of the wood. Tests were then...

  12. Nondestructive methods of evaluating quality of wood in preservative-treated piles

    Science.gov (United States)

    Xiping. Wang; Robert J. Ross; John R. Erickson; John W. Forsman; Gary D. McGinnis; Rodney C. De Groot

    2000-01-01

    Stress-wave-based nondestructive evaluation methods were used to evaluate the potential quality and modulus of elasticity (MOE) of wood in used preservative-treated Douglas-fir and southern pine piles. Stress wave measurements were conducted on each pile section. Stress wave propagation speeds in the piles were then obtained to estimate their MOE. This was followed by...

  13. Nondestructive methods for the structural evaluation of wood floor systems in historic buildings : preliminary results : [abstract

    Science.gov (United States)

    Zhiyong Cai; Michael O. Hunt; Robert J. Ross; Lawrence A. Soltis

    1999-01-01

    To date, there is no standard method for evaluating the structural integrity of wood floor systems using nondestructive techniques. Current methods of examination and assessment are often subjective and therefore tend to yield imprecise or variable results. For this reason, estimates of allowable wood floor loads are often conservative. The assignment of conservatively...

  14. Nondestructive quality evaluation technology of agricultural products

    International Nuclear Information System (INIS)

    Noh, Sang Ha

    1997-01-01

    Quality evaluation of agricultural products has been interested to many researchers for many years and as the result, several nondestructive techniques and so many papers have been reported for quality evaluation of agricultural products. These nondestructive techniques are based on the detection of mechanical, optical, electrical, electro-magnetical, dielectric and vibrational properties of agricultural products that are well correlated with certain quality factors of the products such as color, shape, firmness, sugar content, external or internal defects, moisture content, etc. The sophistication of nondestructive methods has evolved rapidly with modem technologies. In this paper an emphasis was put on reviewing some of those papers and techniques which could be led to on-line measurement for practical use.

  15. Non-destructive testing. V. 2

    International Nuclear Information System (INIS)

    Farley, J.M.; Nichols, R.W.

    1988-01-01

    The book entitled 'Non-destructive Testing' Volume 2, contains the proceedings of the fourth European Conference, organized by the British Institute of Non-Destructive Testing and held in London, September 1987. The volume contains seven chapters which examine the reliability of NDT, the economics of NDT and the use of NDT in:- civil engineering; oil, gas, coal and petrochemical industries; iron and steel industries; aerospace industry; and the nuclear and electricity supply industries. The seven chapters contain 78 papers, of which 19 are selected for INIS and indexed separately. (U.K.)

  16. Non-destructive testing of electronic parts

    International Nuclear Information System (INIS)

    Widenhorn, G.

    1980-01-01

    The requirements on quality, safety, faultlessness and reliability of electric components increase because of the high complexity of the appliances in which they are used. By means of examples a survey is given on the common non-destructive testing methods, testing operation and evaluation of test results on electric components which must meet in their application high requirements on quality and reliability. Defective components, especially those with hidden failures are sorted out by non-destructive testing and the failure frequency of the appliances and plants in testing and operation is greatly reduced. (orig.) [de

  17. Nondestructive characterization of austenitic stainless steels

    International Nuclear Information System (INIS)

    Jayakumar, T.; Kumar, Anish

    2010-01-01

    The paper presents an overview of the non-destructive methodologies developed at the authors' laboratory for characterization of various microstructural features, residual stresses and corrosion in austenitic stainless steels. Various non-destructive evaluation (NDE) parameters such as ultrasonic velocity, ultrasonic attenuation, spectral analysis of the ultrasonic signals, magnetic hysteresis parameters and eddy current amplitude have been used for characterization of grain size, precipitation behaviour, texture, recrystallization, thermomechanical processing, degree of sensitization, formation of martensite from metastable austenite, assessment of residual stresses, degree of sensitization and propensity for intergranular corrosion in different austenitic steels. (author)

  18. Nondestructive analysis of the gold quarter liras

    International Nuclear Information System (INIS)

    Cakir, C.; Guerol, A.; Demir, L.; Sahin, Y.

    2009-01-01

    In this study, we have prepared seven Au-Cu standards in the concentration range of 18-24 (as carat) for nondestructive control of gold quarter liras. Some calibration curves for quantitative analysis of Au in the gold quarter liras that commercially present in Turkey have been plotted using these standard samples. The characteristic X-rays of Au and Cu emitted from these standard samples and the test sample with known composition are recorded by using a Ge(Li) detector. These calibration curves provide a nondestructive analysis of gold quarter liras with the uncertainties about 1.18%. (author)

  19. Non-Destructive Testing for Concrete Structure

    International Nuclear Information System (INIS)

    Tengku Sarah Tengku Amran; Noor Azreen Masenwat; Mohamad Pauzi Ismail

    2015-01-01

    Nondestructive testing (NDT) is a technique to determine the integrity of a material, component or structure. It is essential in the inspection of alteration, repair and new construction in the building industry. There are a number of non-destructive testing techniques that can be applied to determine the integrity of concrete in a completed structure. Each has its own advantages and limitations. For concrete, these problems relate to strength, cracking, dimensions, delamination, and inhomogeneities. NDT is reasonably good and reliable tool to measure the property of concrete which also gives the fair indication of the compressive strength development. This paper discussed the concrete inspection using combined methods of NDT. (author)

  20. Effects of bisphenol A treatment during pregnancy on kidney development in mice: a stereological and histopathological study.

    Science.gov (United States)

    Nuñez, P; Fernandez, T; García-Arévalo, M; Alonso-Magdalena, P; Nadal, A; Perillan, C; Arguelles, J

    2018-04-01

    Bisphenol A (BPA) is a chemical found in plastics that resembles oestrogen in organisms. Developmental exposure to endocrine-disrupting chemicals, such as BPA, increases the susceptibility to type 2 diabetes (T2DM) and cardiovascular diseases. Animal studies have reported a nephron deficit in offspring exposed to maternal diabetes. The aim of this study was to investigate the prenatal BPA exposure effects on nephrogenesis in a mouse model that was predisposed to T2DM. This study quantitatively evaluated the renal structural changes using stereology and histomorphometry methods. The OF1 pregnant mice were treated with a vehicle or BPA (10 or 100 μg/kg/day) during days 9-16 of gestation (early nephrogenesis). The 30-day-old offspring were sacrificed, and tissue samples were collected and prepared for histopathological and stereology studies. Glomerular abnormalities and reduced glomerular formation were observed in the BPA offspring. The kidneys of the BPA10 and BPA100 female offspring had a significantly lower glomerular number and density than those of the CONTROL female offspring. The glomerular histomorphometry revealed a significant difference between the female and male CONTROL offspring for the analysed glomerular parameters that disappeared in the BPA10 and BPA100 offspring. In addition, the kidney histopathological examination showed typical male cuboidal epithelial cells of the Bowman capsule in the female BPA offspring. Exposure to environmentally relevant doses of BPA during embryonic development altered nephrogenesis. These structural changes could be associated with an increased risk of developing cardiometabolic diseases later in life.

  1. 49 CFR 195.234 - Welds: Nondestructive testing.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Welds: Nondestructive testing. 195.234 Section 195... HAZARDOUS LIQUIDS BY PIPELINE Construction § 195.234 Welds: Nondestructive testing. (a) A weld may be... weld. (b) Any nondestructive testing of welds must be performed— (1) In accordance with a written set...

  2. 46 CFR 151.03-38 - Nondestructive testing.

    Science.gov (United States)

    2010-10-01

    ... CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Definitions § 151.03-38 Nondestructive testing. Nondestructive testing includes ultrasonic examination, liquid penetrant examination, magnetic particle... 46 Shipping 5 2010-10-01 2010-10-01 false Nondestructive testing. 151.03-38 Section 151.03-38...

  3. 49 CFR 193.2321 - Nondestructive tests.

    Science.gov (United States)

    2010-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES... of storage tanks with internal design pressure above 15 psig must be nondestructively examined in... Vessel Code (Section VIII Division 1) (incorporated by reference, see § 193.2013). (b) For storage tanks...

  4. Innovative technology transfer of nondestructive evaluation research

    Science.gov (United States)

    Brian Brashaw; Robert J. Ross; Xiping Wang

    2008-01-01

    Technology transfer is often an afterthought for many nondestructive evaluation (NDE) researchers. Effective technology transfer should be considered during the planning and execution of research projects. This paper outlines strategies for using technology transfer in NDE research and presents a wide variety of technology transfer methods used by a cooperative...

  5. The real defect and its nondestructive characterization

    International Nuclear Information System (INIS)

    Licht, H.

    1982-01-01

    Nondestructive test techniques to evaluate defect severity and component degradation are typically based on transmission of energy into the material to be inspected. The capabilities of such techniques are controlled by physical phenomena which generally do not coincide with inspection requirements. This paper reviews several recent developments (mainly in ultrasonic and eddy current testing) which highlight the state of the art

  6. Do's and dont's of nondestructive assay measurements

    International Nuclear Information System (INIS)

    Menlove, H.O.

    Some of the problem areas and recommended procedures in the application of nondestructive analysis (NDA) instrumentation are discussed. To limit the scope of the present guide, only radiometric NDA techniques employing neutron and gamma signatures are considered. Thus, measurement techniques which primarily make use of alpha particles, beta particles, muonic x rays, heat signatures, etc., are not included. (U.S.)

  7. Nondestructive examination development and demonstration plan

    International Nuclear Information System (INIS)

    Weber, J.R.

    1991-01-01

    Nondestructive examination (NDE) of waste matrices using penetrating radiation is by nature very subjective. Two candidate systems of examination have been identified for use in WRAP 1. This test plan describes a method for a comparative evaluation of different x-ray examination systems and techniques

  8. New tasks for non-destructive testing

    International Nuclear Information System (INIS)

    1990-01-01

    The proceedings contain 29 lectures and 43 posters which were presented in Trier at the annual meeting of the DGZfP in May 1990. The contributions report on further development of non-destructive testing methods towards more reliability, both of inspections and with regard to interpretation of the results. (MM) [de

  9. Nondestructive assay of boxed radioactive waste

    International Nuclear Information System (INIS)

    Gilles, W.P.; Roberts, R.J.; Jasen, W.G.

    1992-12-01

    This paper describes the problems related to the nondestructive assay (NDA) of boxed radioactive waste at the Hanford Site and how Westinghouse Hanford company (WHC) is solving the problems. The waste form and radionuclide content are described. The characteristics of the combined neutron and gamma-based measurement system are described

  10. Stereological Investigation of the Effects of Treadmill Running Exercise on the Hippocampal Neurons in Middle-Aged APP/PS1 Transgenic Mice.

    Science.gov (United States)

    Chao, Fenglei; Jiang, Lin; Zhang, Yi; Zhou, Chunni; Zhang, Lei; Tang, Jing; Liang, Xin; Qi, Yingqiang; Zhu, Yanqing; Ma, Jing; Tang, Yong

    2018-01-01

    The risk of cognitive decline during Alzheimer's disease (AD) can be reduced if physical activity is maintained; however, the specific neural events underlying this beneficial effect are still uncertain. To quantitatively investigate the neural events underlying the effect of running exercise on middle-aged AD subjects, 12-month-old male APP/PS1 mice were randomly assigned to a control group or running group, and age-matched non-transgenic littermates were used as a wild-type group. AD running group mice were subjected to a treadmill running protocol (regular and moderate intensity) for four months. Spatial learning and memory abilities were assessed using the Morris water maze. Hippocampal amyloid plaques were observed using Thioflavin S staining and immunohistochemistry. Hippocampal volume, number of neurons, and number of newborn cells (BrdU+ cells) in the hippocampus were estimated using stereological techniques, and newborn neurons were observed using double-labelling immunofluorescence. Marked neuronal loss in both the CA1 field and dentate gyrus (DG) and deficits in both the neurogenesis and survival of new neurons in the DG of middle-aged APP/PS1 mice were observed. Running exercise could improve the spatial learning and memory abilities, reduce amyloid plaques in the hippocampi, delay neuronal loss, induce neurogenesis, and promote the survival of newborn neurons in the DG of middle-aged APP/PS1 mice. Exercise-induced protection of neurons and adult neurogenesis within the DG might be part of the important structural basis of the improved spatial learning and memory abilities observed in AD mice.

  11. Nondestructive testing method for a new generation of electronics

    Directory of Open Access Journals (Sweden)

    Azin Anton

    2018-01-01

    Full Text Available The implementation of the Smart City system needs reliable and smoothly operating electronic equipment. The study is aimed at developing a nondestructive testing method for electronic equipment and its components. This method can be used to identify critical design defects of printed circuit boards (PCB and to predict their service life, taking into account the nature of probable operating loads. The study uses an acoustic emission method to identify and localize critical design defects of printed circuit boards. Geometric dimensions of detected critical defects can be determined by the X-ray tomography method. Based on the results of the study, a method combining acoustic emission and X-ray tomography was developed for nondestructive testing of printed circuit boards. The stress-strain state of solder joints containing detected defects was analyzed. This paper gives an example of using the developed method for estimating the degree of damage to joints between PCB components and predicting the service life of the entire PCB.

  12. Nondestructive nuclear measurement in the fuel cycle. Part 1

    International Nuclear Information System (INIS)

    Lyoussi, A.

    2005-01-01

    Nondestructive measurement techniques are today widely used in practically all steps of the fuel cycle. This article is devoted to the presentation of the control and characterization needs and to the main passive nondestructive nuclear methods used: 1 - nondestructive nuclear measurement, needs and motivation: nuclear fuel cycle, nondestructive nuclear measurements (passive and active methods), comments; 2 - main passive nondestructive nuclear measurement methods: gamma spectroscopy (principle, detectors, electronic systems, data acquisition and signal processing, domains of application, main limitations), passive neutronic measurements (needs and motivations, neutron detectors, total neutronic counting, neutronic coincidences counting, neutronic multiplicities counting, comments). (J.S.)

  13. Modelos para la estimación no destructiva del área foliar de dos cultivares de mandioca (Manihot esculenta Crantz en la Argentina Models for non-destructive leaf area estimation of two cassava (Manihot esculenta crantz cultivars in Argentina

    Directory of Open Access Journals (Sweden)

    A.M. Burgos

    2010-06-01

    fit and precision to estimate LA was: LA = ß0 + ß1.PL(cm +ß2.CLA(cm² + ß3.ΣLL(cm , based on non-destructive and easy to measure dimensions. This model needs different estimations of the parameters for each cultivar. The results obtained in this research showed that under the evaluated conditions and for both cultivars, leaf area might be estimated using simple linear measurements, as petiole length, sum total of lobes length and central lobe area.

  14. Mast cells and atopic dermatitis. Stereological quantification of mast cells in atopic dermatitis and normal human skin

    DEFF Research Database (Denmark)

    Damsgaard, T E; Olesen, A B; Sørensen, Flemming Brandt

    1997-01-01

    Stereological quantification of mast cell numbers was applied to sections of punch biopsies from lesional and nonlesional skin of atopic dermatitis patients and skin of healthy volunteers. We also investigated whether the method of staining and/or the fixative influenced the results...... of the determination of the mast cell profile numbers. The punch biopsies were taken from the same four locations in both atopic dermatitis patients and normal individuals. The locations were the scalp, neck and flexure of the elbow (lesional skin), and nates (nonlesional skin). Clinical scoring was carried out...... yielded the following results: (1) in atopic dermatitis lesional skin an increased number of mast cell profiles was found as compared with nonlesional skin, (2) comparing atopic dermatitis skin with normal skin, a significantly increased number of mast cell profiles per millimetre squared was found...

  15. Degeneration and regeneration of motor and sensory nerves: a stereological study of crush lesions in rat facial and mental nerves

    DEFF Research Database (Denmark)

    Barghash, Ziad; Larsen, Jytte Overgaard; Al-Bishri, Awad

    2013-01-01

    The aim of this study was to evaluate the degeneration and regeneration of a sensory nerve and a motor nerve at the histological level after a crush injury. Twenty-five female Wistar rats had their mental nerve and the buccal branch of their facial nerve compressed unilaterally against a glass rod...... for 30 s. Specimens of the compressed nerves and the corresponding control nerves were dissected at 3, 7, and 19 days after surgery. Nerve cross-sections were stained with osmium tetroxide and toluidine blue and analysed using two-dimensional stereology. We found differences between the two nerves both...... in the normal anatomy and in the regenerative pattern. The mental nerve had a larger cross-sectional area including all tissue components. The mental nerve had a larger volume fraction of myelinated axons and a correspondingly smaller volume fraction of endoneurium. No differences were observed...

  16. Mast cells and atopic dermatitis. Stereological quantification of mast cells in atopic dermatitis and normal human skin

    DEFF Research Database (Denmark)

    Damsgaard, T E; Olesen, A B; Sørensen, Flemming Brandt

    1997-01-01

    Stereological quantification of mast cell numbers was applied to sections of punch biopsies from lesional and nonlesional skin of atopic dermatitis patients and skin of healthy volunteers. We also investigated whether the method of staining and/or the fixative influenced the results...... of the determination of the mast cell profile numbers. The punch biopsies were taken from the same four locations in both atopic dermatitis patients and normal individuals. The locations were the scalp, neck and flexure of the elbow (lesional skin), and nates (nonlesional skin). Clinical scoring was carried out...... at the site of each biopsy. After fixation and plastic embedding, the biopsies were cut into 2 microns serial sections. Ten sections, 30 microns apart, from each biopsy were examined and stained alternately with either toluidine blue or Giemsa stain and mast cell profile numbers were determined. The study...

  17. Economic importance of non-destructive testing

    International Nuclear Information System (INIS)

    Loebert, P.

    1979-01-01

    On May 21 to 23, 1979, the annual meeting of the Deutsche Gesellschaft fuer Zerstoerungsfreie Pruefung took place in Lindau near the Bodensee lake. About 600 experts from Germany and abroad participated in the meeting, whose general subject was 'The Economic Importance of Non-Destructive Testing'. Theoretical problems and practical investigations were discussed in a number of papers on special subjects. Apart from the 33 papers, there was also a poster show with 53 stands with texts, drawings, diagrams, and figures where the authors informed those interested on the latest state of knowledge in testing. The short papers were read in six sessions under the headings of rentability of non-destructive testing, X-ray methods, electromagnetic methods, and ultrasonic methods 1 and 2. (orig.) [de

  18. Improvement of the reliability on nondestructive inspection

    International Nuclear Information System (INIS)

    Song, Sung Jin; Kim, Young H.; Lee, Hyang Beom; Shin, Young Kil; Jung, Hyun Jo; Park, Ik Keun; Park, Eun Soo

    2002-03-01

    Retaining reliabilities of nondestructive testing is essential for the life-time maintenance of Nuclear Power Plant. The nondestructive testing methods which are frequently used in the Nuclear Power Plant are eddy current testing for the inspection of steam generator tubes and ultrasonic testing for the inspection of weldments. In order to improve reliabilities of ultrasonic testing and eddy current testing, the subjects carried out in this study are as follows : development of BEM analysis technique for ECT of SG tube, development of neural network technique for the intelligent analysis of ECT flaw signals of SG tubes, development of RFECT technology for the inspection of SG tube, FEM analysis of ultrasonic scattering field, evaluation of statistical reliability of PD-RR test of ultrasonic testing and development of multi-Gaussian beam modeling technique to predict accurate signal of signal beam ultrasonic testing with the efficiency in calculation time

  19. Improvement of the reliability on nondestructive inspection

    Energy Technology Data Exchange (ETDEWEB)

    Song, Sung Jin; Kim, Young H. [Sungkyunkwan Univ., Suwon (Korea, Republic of); Lee, Hyang Beom [Soongsil Univ., Seoul (Korea, Republic of); Shin, Young Kil [Kunsan National Univ., Gunsan (Korea, Republic of); Jung, Hyun Jo [Wonkwang Univ., Iksan (Korea, Republic of); Park, Ik Keun; Park, Eun Soo [Seoul Nationl Univ., Seoul (Korea, Republic of)

    2002-03-15

    Retaining reliabilities of nondestructive testing is essential for the life-time maintenance of Nuclear Power Plant. The nondestructive testing methods which are frequently used in the Nuclear Power Plant are eddy current testing for the inspection of steam generator tubes and ultrasonic testing for the inspection of weldments. In order to improve reliabilities of ultrasonic testing and eddy current testing, the subjects carried out in this study are as follows : development of BEM analysis technique for ECT of SG tube, development of neural network technique for the intelligent analysis of ECT flaw signals of SG tubes, development of RFECT technology for the inspection of SG tube, FEM analysis of ultrasonic scattering field, evaluation of statistical reliability of PD-RR test of ultrasonic testing and development of multi-Gaussian beam modeling technique to predict accurate signal of signal beam ultrasonic testing with the efficiency in calculation time.

  20. Non-destructive control of castings

    International Nuclear Information System (INIS)

    Boutault, J.; Mascre, C.

    1978-01-01

    The object of non-destructive control in foundries is to verify the metal structure, the absence of unacceptable discontinuity, total tightness, etc. This leads to a range of very varied controls according to the importance of the series, the quality level required by the specifications, the nature of the alloy. The originality of the solutions which are imperative for castings is shown through examples: casting of high quality complex forms in short series; very thick unit parts; very large series of parts requiring on efficient automation of non-destructive control. Lastly the publishing of testing methods and interpretating rules, which are the base of a friendly understanding between constructors and founders are recalled [fr

  1. Nondestructive examination techniques on Candu fuel elements

    International Nuclear Information System (INIS)

    Gheorghe, G.; Man, I.

    2013-01-01

    During irradiation in nuclear reactor, fuel elements undergo dimensional and structural changes, and changes of surface conditions sheath as well, which can lead to damages and even loss of integrity. Visual examination and photography of Candu fuel elements are among the non-destructive examination techniques, next to dimensional measurements that include profiling (diameter, bending, camber) and length, sheath integrity control with eddy currents, measurement of the oxide layer thickness by eddy current techniques. Unirradiated Zircaloy-4 tubes were used for calibration purposes, whereas irradiated Zircaloy-4 tubes were actually subjected to visual inspection and dimensional measurements. We present results of measurements done by eddy current techniques on Zircaloy- 4 tubes, unirradiated, but oxidized in an autoclave prior to examinations. The purpose of these nondestructive examination techniques is to determine those parameters that characterize the behavior and performance of nuclear fuel operation. (authors)

  2. The European conference on nondestructive testing

    International Nuclear Information System (INIS)

    Klyuev, V.V.

    1985-01-01

    Information on the 3-d European conference on nondestructive testing (NT) held in October, 1984 in Florence, is presented. Plenary reports were devoted to complex use of different NT methods, tendencies to NT automation and robotics, transition from defectoscopy to quality control, determination of phisico-mechanical properties of items using different control methods, formulation of unified international programs on professional training and qualification. Section reports cover the following directions: NT use in aviation and astronautics, construction, welding engineering, studying works of art; personnel training, economics, NT functioning, automation, calibration, standardization, quality control over metallic and nonmetallic objects. Some reports concerned nondestructive testing of items during their use. Attention is paied to radiographic testing and neutron radiography as well as to image processing. NT equipment was also discussed

  3. Emerging nondestructive inspection methods for aging aircraft

    Energy Technology Data Exchange (ETDEWEB)

    Beattie, A; Dahlke, L; Gieske, J [and others

    1994-01-01

    This report identifies and describes emerging nondestructive inspection (NDI) methods that can potentially be used to inspect commercial transport and commuter aircraft for structural damage. The nine categories of emerging NDI techniques are: acoustic emission, x-ray computed tomography, backscatter radiation, reverse geometry x-ray, advanced electromagnetics, including magnetooptic imaging and advanced eddy current techniques, coherent optics, advanced ultrasonics, advanced visual, and infrared thermography. The physical principles, generalized performance characteristics, and typical applications associated with each method are described. In addition, aircraft inspection applications are discussed along with the associated technical considerations. Finally, the status of each technique is presented, with a discussion on when it may be available for use in actual aircraft maintenance programs. It should be noted that this is a companion document to DOT/FAA/CT-91/5, Current Nondestructive Inspection Methods for Aging Aircraft.

  4. Holographic nondestructive testing in bone biomechanics

    Science.gov (United States)

    Silvennoinen, Raimo V. J.; Nygren, Kaarlo; Karna, Markku

    1992-08-01

    Holographic nondestructive testing (HNDT) is used to investigate the complex structures of bones of various shapes and sizes subjected to forces. During the course of the present study three antlered deer skulls of different species were investigated, and significant species- specific differences were observed. The HNDT method was also used to verify the advanced healing of an osteosynthetized sheep jawbone. Radioulnar bones of normal and orphaned moose calves were subjected to the bending test. Different bending dynamics were observed.

  5. Non-destructive control in nuclear construction

    International Nuclear Information System (INIS)

    Banus; Barbier; Launay

    1978-01-01

    Having recalled the characteristics of the fundamental components of the main primary circuit of nuclear boilers (900 MW) and the means appropriated for their control, it is recalled that the 'French Electricity Board's specifications and control rules' often prescribe more severe criteria than those existing in the U.S.A. Then practical examples of non-destructive controls concerning the steam generator end plates, vessel stainless steel linings, pump attachements, steam generator pipes are given [fr

  6. Nondestructive assay methodologies in nuclear forensics analysis

    International Nuclear Information System (INIS)

    Tomar, B.S.

    2016-01-01

    In the present chapter, the nondestructive assay (NDA) methodologies used for analysis of nuclear materials as a part of nuclear forensic investigation have been described. These NDA methodologies are based on (i) measurement of passive gamma and neutrons emitted by the radioisotopes present in the nuclear materials, (ii) measurement of gamma rays and neutrons emitted after the active interrogation of the nuclear materials with a source of X-rays, gamma rays or neutrons

  7. Development of non-destructive testing. Turkey

    International Nuclear Information System (INIS)

    1991-01-01

    A National Scheme for the qualification and certification of Non-Destructive Testing (NDT) personnel in various methods has been established as the first stage of implementation. Systematic training in such methods as radiography (RT), ultrasonics (UT), magnetic particles (MT), liquid penetrant (PT) and eddy currents (ET) at levels I, II and some at III has been initiated and should be continued. Direct link with the industry and continuous effort to extend practical applications is strongly recommended

  8. Analytical nondestructive evaluation for materials characterization

    International Nuclear Information System (INIS)

    Raj, Baldev

    1993-01-01

    Science and technology of nondestructive testing and evaluation has contributed immensely to the safety and productivity of industrial plants. In recent years, nondestructive evaluation (NDE) has emerged as a frontline research area of equal if not greater technological relevance, for materials characterization as well. A comprehensive range of techniques from qualitative nondestructive testing for quality control of engineering products and materials to quantitative NDE for materials characterization is being used by the engineering industry and materials researchers, for better understanding of the manufacturing practices and materials behaviour. Quantitative NDE is considered essential for ensuring fitness for purpose at the start of the life in case the component has been designed using fracture mechanics parameters. Quantitative NDE is also vital for assessing degradation of material during service. Moreover, quantitative NDE enables characterization of dynamics of certain phenomenon (not achievable by destructive test methodologies) leading to better understanding of the performance of materials in relation to unavoidable defects in the materials. As the next logical step, the need for an analytical approach to NDE is felt. The need and motivation for such an approach is addressed and the means to achieve this objective are identified. It is argued that analytical NDE is essential to meet the challenges of characterization, intelligent processing of materials and life prediction of components and plants. These requirements are of significant importance in the context of recent developments in materials engineering, and for enhancing the competitive advantage of Indian engineering industry in the international market. (author). 9 refs., 3 figs

  9. Nondestructive Assay Data Integration with the SKB-50 Assemblies - FY16 Update

    International Nuclear Information System (INIS)

    Tobin, Stephen Joseph; Fugate, Michael Lynn; Trellue, Holly Renee; DeBaere, Paul; Sjoland, Anders; Liljenfeldt, Henrik; Hu, Jianwei; Backstrom, Ulrika; Bengtsson, Martin; Burr, Tomas; Eliasson, Annika; Favalli, Andrea; Gauld, Ian; Grogan, Brandon; Jansson, Peter; Junell, Henrik; Schwalbach, Peter; Vaccaro, Stefano; Vo, Duc Ta; Wildestrand, Henrik

    2016-01-01

    A project to research the application of non-destructive assay (NDA) techniques for spent fuel assemblies is underway at the Central Interim Storage Facility for Spent Nuclear Fuel (for which the Swedish acronym is Clab) in Oskarshamn, Sweden. The research goals of this project contain both safeguards and non-safeguards interests. These nondestructive assay (NDA) technologies are designed to strengthen the technical toolkit of safeguard inspectors and others to determine the following technical goals more accurately; Verify initial enrichment, burnup, and cooling time of facility declaration for spent fuel assemblies; Detect replaced or missing pins from a given spent fuel assembly to confirm its integrity; and Estimate plutonium mass and related plutonium and uranium fissile mass parameters in spent fuel assemblies. Estimate heat content, and measure reactivity (multiplication).

  10. Nondestructive Assay Data Integration with the SKB-50 Assemblies - FY16 Update

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, Stephen Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Fugate, Michael Lynn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Trellue, Holly Renee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); DeBaere, Paul [DG Energy, Luxembourg (Germany); Sjoland, Anders [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Liljenfeldt, Henrik [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hu, Jianwei [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Backstrom, Ulrika [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Vattenfall AB, Stockholm (Sweden); Bengtsson, Martin [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Vattenfall AB, Stockholm (Sweden); Burr, Tomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); International Atomic Energy Agency, Vienna (Austria); Eliasson, Annika [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Favalli, Andrea [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Gauld, Ian [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Grogan, Brandon [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jansson, Peter [Uppsala Univ. (Sweden); Junell, Henrik [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Schwalbach, Peter [DG Energy, Luxembourg (Germany); Vaccaro, Stefano [DG Energy, Luxembourg (Germany); Vo, Duc Ta [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wildestrand, Henrik [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Vattenfall AB, Stockholm (Sweden)

    2016-10-28

    A project to research the application of non-destructive assay (NDA) techniques for spent fuel assemblies is underway at the Central Interim Storage Facility for Spent Nuclear Fuel (for which the Swedish acronym is Clab) in Oskarshamn, Sweden. The research goals of this project contain both safeguards and non-safeguards interests. These nondestructive assay (NDA) technologies are designed to strengthen the technical toolkit of safeguard inspectors and others to determine the following technical goals more accurately; Verify initial enrichment, burnup, and cooling time of facility declaration for spent fuel assemblies; Detect replaced or missing pins from a given spent fuel assembly to confirm its integrity; and Estimate plutonium mass and related plutonium and uranium fissile mass parameters in spent fuel assemblies. Estimate heat content, and measure reactivity (multiplication).

  11. Non-destructive measurement of Xe filling pressure in mercury-free metal halide lamp

    International Nuclear Information System (INIS)

    Motomura, Hideki; Enoki, Kyosuke; Jinno, Masafumi

    2010-01-01

    Mercury-free metal halide lamps (MHLs) for automotive purposes have been developing in the market. When mercury is not used, the electric and emission characteristics of the lamp strongly depend on the xenon filling pressure. Therefore a non-destructive gas pressure estimation technique is required to obtain stable performance of the lamps as commercial products. The authors have developed an estimation method by which the gas pressure is estimated from the current peak value at the initial stage of ignition under pulsed operation. It is shown that accuracy of the order of ±(0.1-0.3) atm is obtained using an empirical formula.

  12. Novel efficient methods for measuring mesophyll anatomical characteristics from fresh thick sections using stereology and confocal microscopy: application on acid rain-treated Norway spruce needles

    Czech Academy of Sciences Publication Activity Database

    Albrechtová, Jana; Janáček, Jiří; Lhotáková, Zuzana; Radochová, Barbora; Kubínová, Lucie

    2007-01-01

    Roč. 58, č. 6 (2007), s. 1451-1461 ISSN 0022-0957 R&D Projects: GA AV ČR IAA5011810; GA AV ČR(CZ) IAA600110507; GA MŠk(CZ) LC06063 Institutional research plan: CEZ:AV0Z50110509; CEZ:AV0Z60050516 Keywords : mesophyll * stereology * confocal microscopy Subject RIV: EA - Cell Biology Impact factor: 3.917, year: 2007

  13. Nondestructive testing standards and the ASME code

    International Nuclear Information System (INIS)

    Spanner, J.C.

    1991-04-01

    Nondestructive testing (NDT) requirements and standards are an important part of the ASME Boiler and Pressure Vessel Code. In this paper, the evolution of these requirements and standards is reviewed in the context of the unique technical and legal stature of the ASME Code. The coherent and consistent manner by which the ASME Code rules are organized is described, and the interrelationship between the various ASME Code sections, the piping codes, and the ASTM Standards is discussed. Significant changes occurred in ASME Sections 5 and 11 during the 1980s, and these are highlighted along with projections and comments regarding future trends and changes in these important documents. 4 refs., 8 tabs

  14. Nondestructive measurement of environmental radioactive strontium

    Directory of Open Access Journals (Sweden)

    Saiba Shuntaro

    2014-03-01

    Full Text Available The Fukushima Daiichi nuclear power plant accident was triggered by the 2011 Great East Japan Earthquake. The main radioactivity concerns after the accident are I-131 (half-life: 8.0 days, Cs-134 (2.1 years, Cs-137 (30 years, Sr-89 (51 days, and Sr-90 (29 years. We are aiming to establish a new nondestructive measurement and detection technique that will enable us to realize a quantitative evaluation of strontium radioactivity without chemical separation processing. This technique is needed to detect radiation contained in foods, environmental water, and soil, to prevent us from undesired internal exposure to radiation.

  15. ARIES nondestructive assay system operation and performance

    International Nuclear Information System (INIS)

    Cremers, Teresa L.; Hansen, Walter J.; Herrera, Gary D.; Nelson, David C.; Sampson, Thomas E.; Scheer, Nancy L.

    2000-01-01

    The ARIES (Advanced Recovery and Integrated Extraction System) Project is an integrated system at the Los Alamos Plutonium Facility for the dismantlement of nuclear weapons. The plutonium produced by the ARIES process was measured by an integrated nondestructive assay (NDA) system. The performance of the NDA systems was monitored by a measurement control program which is a part of a nuclear material control and accountability system. In this paper we will report the results of the measurements of the measurement control standards as well as an overview of the measurement of the ARIES process materials

  16. Review of progress in quantitative nondestructive evaluation

    International Nuclear Information System (INIS)

    Thompson, D.O.; Chimenti, D.E.

    1983-01-01

    A comprehensive review of the current state of quantitative nondestructive evaluation (NDE), this volume brings together papers by researchers working in government, private industry, and university laboratories. Their papers cover a wide range of interests and concerns for researchers involved in theoretical and applied aspects of quantitative NDE. Specific topics examined include reliability probability of detection--ultrasonics and eddy currents weldments closure effects in fatigue cracks technology transfer ultrasonic scattering theory acoustic emission ultrasonic scattering, reliability and penetrating radiation metal matrix composites ultrasonic scattering from near-surface flaws ultrasonic multiple scattering

  17. Nondestructive analysis of plutonium contaminated soil

    International Nuclear Information System (INIS)

    Smith, H.E.; Taylor, L.H.

    1977-01-01

    Plutonium contaminated soil is currently being removed from a covered liquid waste disposal trench near the Pu Processing facility on the Hanford Project. This soil with the plutonium is being mined using remote techniques and equipment. The mined soil is being packaged for placement into retrievable storage, pending possible recovery. To meet the requirements of criticality safety and materials accountability, a nondestructive analysis program has been developed to determine the quantity of plutonium in each packing-storage container. This paper describes the total measurement program: equipment systems, calibration techniques, matrix assumption, instrument control program and a review of laboratory operating experience

  18. Technical plan for nondestructive examination technology development

    International Nuclear Information System (INIS)

    Anderson, B.C.

    1982-12-01

    This report provides a description of the development of the nondestructive examination (NDE) equipment to be used in the Stored Waste Examination Pilot Plant (SWEPP) for certifying transuranic (TRU) waste for shipment to the Waste Isolation Pilot Plant (WIPP). NDE equipment is being developed for waste identification and container integrity. Real-time x-ray radiography is the basic method being used for waste identification. Acoustic (ultrasonic) testing is being used to obtain measurements to verify container integrity. This report describes the decisions made to date, the decisions to be made, and the activities planned for FY 1983 through FY 1985

  19. Safeguards and Non-destructive Assay

    International Nuclear Information System (INIS)

    Carchon, R.; Bruggeman, M.

    2001-01-01

    SCK-CEN's programme on safeguards and non-destructive assay includes: (1) various activities to assure nuclear materials accountancy; (2) contributes to the implementation of Integrated Safeguards measures in Belgium and to assist the IAEA through the Belgian Support Programme; (3) renders services to internal and external customers in the field of safeguards; (4) improves passive neutron coincidence counting techniques for waste assay and safeguards verification measurements by R and D on correlation algorithms implemented via software or dedicated hardware; (5) improves gamma assay techniques for waste assay by implementing advanced scanning techniques and different correlation algorithms; and (6) develops numerical calibration techniques. Major achievements in these areas in 2000 are reported

  20. Elements of nondestructive assay (NDA) technology

    International Nuclear Information System (INIS)

    Hatcher, C.R.; Smith, H.

    1984-01-01

    A thorough introduction to nondestructive assay methods and instruments as they are applied to nuclear safeguards is presented. The general principles and major applications of NDA are discussed and situations in which NDA is particularly useful for nuclear safeguards purposes are described. Various passive and active γ-ray and neutron methods are examined and assay situations particularly suited to γ-ray techniques, or to neutron techniques are identified. The role of calorimetry in the NDA of plutonium-bearing materials is also discussed. The advantages and disadvantages of various NDA methods for different types of nuclear materials are mentioned

  1. Nondestructive identification of the Bell diagonal state

    International Nuclear Information System (INIS)

    Jin Jiasen; Yu Changshui; Song Heshan

    2011-01-01

    We propose a scheme for identifying an unknown Bell diagonal state. In our scheme the measurements are performed on the probe qubits instead of the Bell diagonal state. The distinct advantage is that the quantum state of the evolved Bell diagonal state ensemble plus probe states will still collapse on the original Bell diagonal state ensemble after the measurement on probe states; i.e., our identification is quantum state nondestructive. How to realize our scheme in the framework of cavity electrodynamics is also shown.

  2. Ionizing radiations for non-destructive evaluation

    International Nuclear Information System (INIS)

    Raj, Baldev; Venkataraman, B.

    1989-01-01

    A state of the art of major non-destructive testing (NDT) techniques based on ionising radiations is presented. These techniques are broadly classified into three categories, namely, radiography, radiation gaging and analytical applications. The basic principles behind each method are explained and salient features of each technique which make it suitable for a particular task are described. Several illustrative applications drawn from the nuclear industry are given. The monograph is intended to serve as an introductory guide to scientist and engineers engaged in NDT activities. (M.G.B.). 32 refs., 13 figs., 5 tabs

  3. Nondestructive diagnosis of multilayer electronic plates

    International Nuclear Information System (INIS)

    Matvienko, A.N.; Savin, D.O.; Yas'ko, A.V.

    1992-01-01

    Methods of non-destructive tomographic investigation into multilayer printed plates using x radiation are described. Mathematic problem setting is given, experimental facility and methods for source data ecquisition are described. A special attention is paid to the consideration of the main factors differing the actual problem setting from the idealized one. Methods for accounting and correction of these factors are described. The efficiency of the approach proposed is demonstrated using the actual problems of reducing separate layers of multilayer printed plate metallization. The method developed is useful when exersizing control over multilayer printed plate production

  4. Neuronal precursor cell proliferation in the hippocampus after transient cerebral ischemia: a comparative study of two rat strains using stereological tools.

    Science.gov (United States)

    Kelsen, Jesper; Larsen, Marianne H; Sørensen, Jens Christian; Møller, Arne; Frøkiaer, Jørgen; Nielsen, Søren; Nyengaard, Jens R; Mikkelsen, Jens D; Rønn, Lars Christian B

    2010-04-06

    We are currently investigating microglial activation and neuronal precursor cell (NPC) proliferation after transient middle cerebral artery occlusion (tMCAo) in rats. This study aimed: (1) to investigate differences in hippocampal NPC proliferation in outbred male spontaneously hypertensive rats (SHRs) and Sprague-Dawley rats (SDs) one week after tMCAo; (2) to present the practical use of the optical fractionator and 2D nucleator in stereological brain tissue analyses; and (3) to report our experiences with an intraluminal tMCAo model where the occluding filament is advanced 22 mm beyond the carotid bifurcation and the common carotid artery is clamped during tMCAo. Twenty-three SDs and twenty SHRs were randomized into four groups subjected to 90 minutes tMCAo or sham. BrdU (50 mg/kg) was administered intraperitoneally twice daily on Day 4 to 7 after surgery. On Day 8 all animals were euthanized. NeuN-stained tissue sections were used for brain and infarct volume estimation with the 2D nucleator and Cavalieri principle. Brains were studied for the presence of activated microglia (ED-1) and hippocampal BrdU incorporation using the optical fractionator. We found no significant difference or increase in post-ischemic NPC proliferation between the two strains. However, the response to remote ischemia may differ between SDs and SHRs. In three animals increased post-stroke NPC proliferation was associated with hippocampal ischemic injury. The mean infarct volume was 89.2 +/- 76.1 mm3 in SHRs and 16.9 +/- 22.7 mm3 in SDs (p < 0.005). Eight out of eleven SHRs had ischemic neocortical damage in contrast to only one out of 12 SDs. We observed involvement of the anterior choroidal and hypothalamic arteries in several animals from both strains and the anterior cerebral artery in two SHRs. We found no evidence of an early hippocampal NPC proliferation one week after tMCAo in both strains. Infarction within the anterior choroidal artery could induce hippocampal ischemia and

  5. Construction and Test of Low Cost X-Ray Tomography Scanner for Physical-Chemical Analysis and Nondestructive Inspections

    International Nuclear Information System (INIS)

    Oliveira, Jose Martins Jr. de; Martins, Antonio Cesar Germano

    2009-01-01

    X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe the development of a low cost micro-CT X-ray scanner that is being developed for nondestructive testing. This tomograph operates using a microfocus X-ray source and contains a silicon photodiode as detectors. The performance of the system, by its spatial resolution, has been estimated through its Modulation Transfer Function-MTF and the obtained value at 10% of MTF is 661 μm. It was built as a general purpose nondestructive testing device.

  6. Nondestructive examination requirements for PWR vessel internals

    International Nuclear Information System (INIS)

    Spanner, J.

    2015-01-01

    This paper describes the requirements for the nondestructive examination of pressurized water reactor (PWR) vessel internals in accordance with the requirements of the EPRI Material Reliability Program (MRP) inspection standard for PWR internals (MRP-228) and the American Society of Mechanical Engineers Section XI In-service Inspection. The MRP vessel internals examinations have been performed at nuclear plants in the USA since 2009. The objective of the inspection standard is to provide the requirements for the nondestructive examination (NDE) methods implemented to support the inspection and evaluation of the internals. The inspection standard contains requirements specific to the inspection methodologies involved as well as requirements for qualification of the NDE procedures, equipment and personnel used to perform the vessel internals inspections. The qualification requirements for the NDE systems will be summarized. Six PWR plants in the USA have completed inspections of their internals using the Inspection and Evaluation Guideline (MRP-227) and the Inspection Standard (MRP-228). Examination results show few instances of service-induced degradation flaws, as expected. The few instances of degradation have mostly occurred in bolting

  7. Non-destructive testing; Examenes no destructivos

    Energy Technology Data Exchange (ETDEWEB)

    Calva, Mauricio; Loske, Achim [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    The application of non-destructive testing (NDT) in several technical and industrial fields is pointed out, standing out its utilization in the detection of future failures without affecting the examined element. Likewise, the different types of NDTs and their processes, such as x-rays, ultrasoud, magnetic particles, induced currents, penetrating fluids, and optical means, are described. The Non-Destructive Tests Laboratory of the Instituto de Investigaciones Electricas (IIE), plans to create new and more reliable systems independent from the operator`s capacity, to contribute to fulfill the inspection and quality control needs of the generating Mexican power plants. [Espanol] Se senala la aplicacion de los examenes no destructivos (END) a diversos campos tecnicos e industriales, destacando su utilizacion en la deteccion de futuras fallas sin afectar el elemento examinado. Asimismo, se describen los diferentes tipos de END y sus procesos, tales como radiografia, ultrasonido, particulas magneticas, corrientes inducidas, liquidos penetrantes y metodos opticos. El Laboratorio de Pruebas no Destructivas, del Instituto de Investigaciones Electricas (IIE), planea crear sistemas novedosos mas confiables, que no dependan de la capacidad del operador, para contribuir a satisfacer las necesidades de inspeccion y control de calidad que se presentan en las plantas generadoras de energia mexicanas.

  8. Non-destructive testing; Examenes no destructivos

    Energy Technology Data Exchange (ETDEWEB)

    Calva, Mauricio; Loske, Achim [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    The application of non-destructive testing (NDT) in several technical and industrial fields is pointed out, standing out its utilization in the detection of future failures without affecting the examined element. Likewise, the different types of NDTs and their processes, such as x-rays, ultrasoud, magnetic particles, induced currents, penetrating fluids, and optical means, are described. The Non-Destructive Tests Laboratory of the Instituto de Investigaciones Electricas (IIE), plans to create new and more reliable systems independent from the operator`s capacity, to contribute to fulfill the inspection and quality control needs of the generating Mexican power plants. [Espanol] Se senala la aplicacion de los examenes no destructivos (END) a diversos campos tecnicos e industriales, destacando su utilizacion en la deteccion de futuras fallas sin afectar el elemento examinado. Asimismo, se describen los diferentes tipos de END y sus procesos, tales como radiografia, ultrasonido, particulas magneticas, corrientes inducidas, liquidos penetrantes y metodos opticos. El Laboratorio de Pruebas no Destructivas, del Instituto de Investigaciones Electricas (IIE), planea crear sistemas novedosos mas confiables, que no dependan de la capacidad del operador, para contribuir a satisfacer las necesidades de inspeccion y control de calidad que se presentan en las plantas generadoras de energia mexicanas.

  9. Nondestructive Evaluation Program: Progress in 1986

    International Nuclear Information System (INIS)

    1987-07-01

    The increasing cost of equipment for power generating plants and the potential increases in productivity and safety available through rapidly developing Nondestructive Evaluation (NDE) technology led EPRI to initiate a Nondestructive Evaluation Program in 1974. To date, the major focus has been on light water reactor inspection problems; however, increased application to other systems is now under way. This report presents a comprehensive review of the EPRI effort in the NDE area. Most of the report consists of contractor-supplied progress reports on each current project. An organizational plan of the program is presented in overview. In addition, organization from several viewpoints is presented, e.g., in-service inspection operators, R and D personnel, and utility representatives. The report summarizes significant progress made since the previous EPRI Special Report NP-4315-SR was issued in May 1986. Section 1 contains information about the program organization, and the sections that follow contain contractor-supplied progress reports of each current project. The progress reports are grouped by plant components - pipe, pressure vessel, steam generator and boiler tubes, and turbine. In addition, Part 6 is devoted to discussions of technology transfer

  10. Collaborative, Nondestructive Analysis of Contaminated Soil

    Energy Technology Data Exchange (ETDEWEB)

    Knight, K. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Dai, Z. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Davidson, L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Eppich, G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Lindvall, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Parsons-Davis, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ramon, C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Roberts, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sharp, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Turin, H. J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); LaMont, S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Zidi, T. [Commissariat a l' Energie Atomique (COMENA), Gif-sur-Yvette (France); Belamri, M. [Commissariat a l' Energie Atomique (COMENA), Gif-sur-Yvette (France); Bounatiro, S. [Commissariat a l' Energie Atomique (COMENA), Gif-sur-Yvette (France); Benbouzid, S. [Commissariat a l' Energie Atomique (COMENA), Gif-sur-Yvette (France); Fellouh, A. S. [Commissariat a l' Energie Atomique (COMENA), Gif-sur-Yvette (France); Idir, T. [Commissariat a l' Energie Atomique (COMENA), Gif-sur-Yvette (France); Larbah, Y. [Commissariat a l' Energie Atomique (COMENA), Gif-sur-Yvette (France); Moulay, M. [Commissariat a l' Energie Atomique (COMENA), Gif-sur-Yvette (France); Noureddine, A. [Commissariat a l' Energie Atomique (COMENA), Gif-sur-Yvette (France); Rahal, B. [Commissariat a l' Energie Atomique (COMENA), Gif-sur-Yvette (France)

    2017-12-14

    This report summarizes a joint nondestructive analysis exercise that LLNL, LANL, and COMENA discussed through a collaborative meeting in July 2017. This work was performed as one part of a collaboration with Algeria under Action Sheet 7: “Technical Cooperation and Assistance in Nuclear Forensics”. The primary intent of this exercise was for US and Algerian participants to jointly share results of nondestructive analyses (NDA) of a contaminated soil sample provided by the Algerians and to discuss key observations and analytical approaches. While the two samples were analyzed blind at LLNL and LANL, the soil samples were revealed after the exercise to have a common origin, and to have originated as an IAEA soil sample (IAEA-326, Bojanowski et al., 2001) provided to COMENA as part of a previous exercise. Comparative analysis revealed common findings between the laboratories, and also emphasized the need for standardized operating procedures to improve inter-comparability and confidence in conclusions. Recommended handling practices in the presence of sample heterogeneities were also discussed. This exercise provided an opportunity to demonstrate nuclear forensics analytical capabilities at COMENA, LANL, and LLNL, and identified areas that could benefit from future technical exchanges. Plans were made for a follow-on joint exercise in 2018, involving destructive analyses of the CUP-2 uranium ore concentrate standard.

  11. Nondestructive testing technology for measurement coatings thickness on material

    International Nuclear Information System (INIS)

    Yang Mingtai; Wu Lunqiang; Zhang Lianping

    2008-01-01

    The principle, applicability range, advantage and disadvantage of electromagnetic, eddy current method, β backscatter method and XRF methods for nondestructive testing coating thickness of material have been reviewed. The relevant apparatus and manufacturers have been summarized. And the application and developmental direction of manufacturers for nondestructive testing coatings thickness has been foreshowed. (authors)

  12. ON ESTIMATION AND HYPOTHESIS TESTING OF THE GRAIN SIZE DISTRIBUTION BY THE SALTYKOV METHOD

    Directory of Open Access Journals (Sweden)

    Yuri Gulbin

    2011-05-01

    Full Text Available The paper considers the problem of validity of unfolding the grain size distribution with the back-substitution method. Due to the ill-conditioned nature of unfolding matrices, it is necessary to evaluate the accuracy and precision of parameter estimation and to verify the possibility of expected grain size distribution testing on the basis of intersection size histogram data. In order to review these questions, the computer modeling was used to compare size distributions obtained stereologically with those possessed by three-dimensional model aggregates of grains with a specified shape and random size. Results of simulations are reported and ways of improving the conventional stereological techniques are suggested. It is shown that new improvements in estimating and testing procedures enable grain size distributions to be unfolded more efficiently.

  13. Experimental continuously reinforced concrete pavement parameterization using nondestructive methods

    Directory of Open Access Journals (Sweden)

    L. S. Salles

    Full Text Available ABSTRACT Four continuously reinforced concrete pavement (CRCP sections were built at the University of São Paulo campus in order to analyze the pavement performance in a tropical environment. The sections short length coupled with particular project aspects made the experimental CRCP cracking be different from the traditional CRCP one. After three years of construction, a series of nondestructive testing were performed - Falling Weight Deflectometer (FWD loadings - to verify and to parameterize the pavement structural condition based on two main properties: the elasticity modulus of concrete (E and the modulus of subgrade reaction (k. These properties estimation was obtained through the matching process between real and EverFE simulated basins with the load at the slab center, between two consecutive cracks. The backcalculation results show that the lack of anchorage at the sections end decreases the E and k values and that the longitudinal reinforcement percentage provides additional stiffness to the pavement. Additionally, FWD loadings tangential to the cracks allowed the load transfer efficiency (LTE estimation determination across cracks. The LTE resulted in values above 90 % for all cracks.

  14. Effects of hypertension and ovariectomy on rat hepatocytes. Are amlodipine and lacidipine protective? (A stereological and histological study).

    Science.gov (United States)

    Dursun, Hakan; Albayrak, Fatih; Uyanik, Abdullah; Keleş, Nuri Osman; Beyzagül, Polat; Bayram, Ednan; Halici, Zekai; Altunkaynak, Zuhal Berrin; Süleyman, Halis; Okçu, Nihat; Ünal, Bünyamin

    2010-12-01

    Calcium channel blockers are increasingly used for the treatment of hypertension. Menopause and hypertension are both important risk factors for liver damage and several other circulatory abnormalities. The aim of this study was to determine the effects of amlodipine and lacidipine in an ovariectomy-induced postmenopausal period model and a deoxycorticosterone acetate-salt-induced hypertensive model in rats. In this study, animals were divided into six groups as follows: control (Group 1), hypertension (Group 2), ovariectomy (Group 3), ovariectomy and hypertension (Group 4), ovariectomy, hypertension and amlodipine-treated (Group 5), and ovariectomy, hypertension and lacidipine-treated (Group 6). At the end of the experiment, the livers were removed and tissue samples were histologically and stereologically examined. The numerical densities of the hepatocytes according to group were 0.000422, 0.00329, 0.000272, 0.00259, 0.00374 and 0.000346 μm3, respectively. Significant differences were found between values of all groups (phypertension in Groups 5 and 6. Our experimental results show that both hypertension and the postmenopausal period have negative effects on the number of hepatocytes and histological structure of the liver. Both amlodipine and lacidipine appear to ameliorate the hypertension and/or postmenopausal period-related decrease in hepatocyte number. We thus suggest that lacidipine and particularly amlodipine have important protective and recovering effects on the liver.

  15. Stereological Study on the Positive Effect of Running Exercise on the Capillaries in the Hippocampus in a Depression Model

    Directory of Open Access Journals (Sweden)

    Linmu Chen

    2017-11-01

    Full Text Available Running exercise is an effective method to improve depressive symptoms when combined with drugs. However, the underlying mechanisms are not fully clear. Cerebral blood flow perfusion in depressed patients is significantly lower in the hippocampus. Physical activity can achieve cerebrovascular benefits. The purpose of this study was to evaluate the impacts of running exercise on capillaries in the hippocampal CA1 and dentate gyrus (DG regions. The chronic unpredictable stress (CUS depression model was used in this study. CUS rats were given 4 weeks of running exercise from the fifth week to the eighth week (20 min every day from Monday to Friday each week. The sucrose consumption test was used to measure anhedonia. Furthermore, stereological methods were used to investigate the capillary changes among the control group, CUS/Standard group and CUS/Running group. Sucrose consumption significantly increased in the CUS/Running group. Running exercise has positive effects on the capillaries parameters in the hippocampal CA1 and DG regions, such as the total volume, total length and total surface area. These results demonstrated that capillaries are protected by running exercise in the hippocampal CA1 and DG might be one of the structural bases for the exercise-induced treatment of depression-like behavior. These results suggest that drugs and behavior influence capillaries and may be considered as a new means for depression treatment in the future.

  16. Degeneration and regeneration of motor and sensory nerves: a stereological study of crush lesions in rat facial and mental nerves.

    Science.gov (United States)

    Barghash, Z; Larsen, J O; Al-Bishri, A; Kahnberg, K-E

    2013-12-01

    The aim of this study was to evaluate the degeneration and regeneration of a sensory nerve and a motor nerve at the histological level after a crush injury. Twenty-five female Wistar rats had their mental nerve and the buccal branch of their facial nerve compressed unilaterally against a glass rod for 30s. Specimens of the compressed nerves and the corresponding control nerves were dissected at 3, 7, and 19 days after surgery. Nerve cross-sections were stained with osmium tetroxide and toluidine blue and analysed using two-dimensional stereology. We found differences between the two nerves both in the normal anatomy and in the regenerative pattern. The mental nerve had a larger cross-sectional area including all tissue components. The mental nerve had a larger volume fraction of myelinated axons and a correspondingly smaller volume fraction of endoneurium. No differences were observed in the degenerative pattern; however, at day 19 the buccal branch had regenerated to the normal number of axons, whereas the mental nerve had only regained 50% of the normal number of axons. We conclude that the regenerative process is faster and/or more complete in the facial nerve (motor function) than it is in the mental nerve (somatosensory function). Copyright © 2013 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Long lasting structural changes in primary motor cortex after motor skill learning: a behavioural and stereological study

    Directory of Open Access Journals (Sweden)

    PAOLA MORALES

    2008-12-01

    Full Text Available Many motor skills, once acquired, are stored over a long time period, probably sustained by permanent neuronal changes. Thus, in this paper we have investigated with quantitative stereology the generation and persistence of neuronal density changes in primary motor cortex (MI following motor skill learning (skilled reaching task. Rats were trained a lateralised reaching task during an "early" (22-31 days oíd or "late" (362-371 days oíd postnatal period. The trained and corresponding control rats were sacrificed at day 372, immediately after the behavioural testing. The "early" trained group preserved the learned skilled reaching task when tested at day 372, without requiring any additional training. The "late" trained group showed a similar capacity to that of the "early" trained group for learning the skilled reaching task. All trained animáis ("early" and "late" trained groups showed a significant Ínter hemispheric decrease of neuronal density in the corresponding motor forelimb representation área of MI (cortical layers II-III

  18. Using photons for non-destructive testing of thick materials: a simulation study

    International Nuclear Information System (INIS)

    Oishi, Ryutaro; Nagai, Hideki

    2004-01-01

    Positron annihilation spectroscopy using positron annihilation lifetimes has been successfully studied for non-destructive material testing. A positron inspection probe is annihilated with an electron at the front of the material. The application of the positron lifetime method is restricted to thin materials. A photon with energy exceeding 1.02MeV reaches the materials' depth and can produce a positron through γ-conversion. Such a photon-produced positron is a probe for thick materials. The probability of γ-conversion, however, is low. The method of photon-produced positron annihilation lifetimes is restricted by statistics. We estimated the expected number of events and the statistical uncertainties of the lifetime measurements for a non-destructive test, such as an SUS316 fatigue monitoring, to construct a fatigue-monitoring system

  19. 234Th distributions in coastal and open ocean waters by non-destructive β-counting

    International Nuclear Information System (INIS)

    Miller, L.A.; Svaeren, I.

    2003-01-01

    Non-destructive β-counting analyses of particulate and dissolved 234 Th activities in seawater are simpler but no less precise than traditional radioanalytical methods. The inherent accuracy limitations of the non-destructive β-counting method, particularly in samples likely to be contaminated with anthropogenic nuclides, are alleviated by recounting the samples over several half-lives and fitting the counting data to the 234 Th decay curve. Precision (including accuracy, estimated at an average of 3%) is better than 10% for particulate or 5% for dissolved samples. Thorium-234 distributions in the Skagerrak indicated a vigorous, presumably biological, particle export from the surface waters, and while bottom sediment resuspension was not an effective export mechanism, it did strip thorium from the dissolved phase. In the Greenland and Norwegian Seas, we saw clear evidence of particulate export from the surface waters, but at 75 m, total 234 Th activities were generally in equilibrium with 238 U. (author)

  20. Nondestructive detection of microstructural fatigue damage

    International Nuclear Information System (INIS)

    Willems, H.; Persch, H.

    1990-02-01

    Ultrasonic as well as magnetic investigations have been performed on a pressure vessel steel (A533, B class 1) in order to study the influence of fatigue loading on both elastic and magnetic material properties. Using laboratory specimens under two different loading conditions (tension-tension loading, tension-compression loading), material characteristics like ultrasonic velocity, ultrasonic absorption, coercivity, incremental permeability were measured and evaluated as a function of consumed lifetime. Only in case of macroscopic plastic deformation, significant changes of the measuring quantities were observed. Otherwise the effects are so small that the nondestructive detection of microstructural changes due to fatigue loading seems not to be feasible under practical conditions (for example at pressure vessels) with the techniques used. Besides a zero measurement, additional measurements on a 1:5 model vessel at JRC Ispra could not be carried out, because the planned fatigue tests were not performed by JRC Ispra during the research period

  1. Nondestructive detection of microstructural fatigue damage

    International Nuclear Information System (INIS)

    Willems, H.; Persch, H.; Voss, B.; Falk, L.

    1989-01-01

    Ultrasonic as well as magnetic investigations have been performed on a pressure vessel steel (A533, B class 1) in order to study the influence of fatigue loading on both elastic and magnetic material properties. Using laboratory specimens under two different loading conditions (tension-tension loading, tension-compression loading), material characteristics like ultrasonic velocity, ultrasonic absorption, coercivity, incremental permeability were measured and evaluated as a function of consumed lifetime. Only in case of macroscopic plastic deformation, significant changes of the measuring quantities were observed. Otherwise the effects are so small that the nondestructive detection of microstructural changes due to high-cycle fatigue loading seems not to be feasible under practical conditions (for example at pressure vessels) with the techniques used. (orig.) [de

  2. Nondestructive Assay Options for Spent Fuel Encapsulation

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jansson, Peter [Uppsala Univ. (Sweden)

    2014-10-02

    This report describes the role that nondestructive assay (NDA) techniques and systems of NDA techniques may have in the context of an encapsulation and deep geological repository. The potential NDA needs of an encapsulation and repository facility include safeguards, heat content, and criticality. Some discussion of the facility needs is given, with the majority of the report concentrating on the capability and characteristics of individual NDA instruments and techniques currently available or under development. Particular emphasis is given to how the NDA techniques can be used to determine the heat production of an assembly, as well as meet the dual safeguards needs of 1) determining the declared parameters of initial enrichment, burn-up, and cooling time and 2) detecting defects (total, partial, and bias). The report concludes with the recommendation of three integrated systems that might meet the combined NDA needs of the encapsulation/repository facility.

  3. Nondestructive Testing of Materials and Structures

    CERN Document Server

    Akkaya, Yılmaz

    2013-01-01

    Condition assessment and characterization of materials and structures by means of nondestructive testing (NDT) methods is a priority need around the world to meet the challenges associated with the durability, maintenance, rehabilitation, retrofitting, renewal and health monitoring of new and existing infrastructures including historic monuments. Numerous NDT methods that make use of certain components of the electromagnetic and acoustic spectra are currently in use to this effect with various levels of success and there is an intensive worldwide research effort aimed at improving the existing methods and developing new ones. The knowledge and information compiled in this book captures the current state-of-the-art in NDT methods and their application to civil and other engineering materials and structures. Critical reviews and advanced interdisciplinary discussions by world-renowned researchers point to the capabilities and limitations of the currently used NDT methods and shed light on current and future res...

  4. Elements of nondestructive assay (NDA) technology

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This session provides an introduction to nondestructive assay methods and instruments as they are applied to nuclear safeguards. The purpose of the sessions is to enable participants to: (1) discuss the general principles and major applications of NDA; (2) describe situations in which NDA is particularly useful for nuclear safeguards purposes; (3) distinguish between various passive and active gamma-ray and neutron NDA methods; (4) describe several NDA instruments that measure gamma rays, and identify assay situations particularly suited to gamma-ray techniques; (5) describe several NDA instruments that measure neutrons, and identify assay situations particularly suited to neutron techniques; (6) discuss the role of calorimetry in the NDA of plutonium-bearing materials; and (7) compare the advantages and disadvantages of various NDA methods for different types of nuclear materials

  5. Review of progress in quantitative nondestructive evaluation

    CERN Document Server

    Chimenti, Dale

    1999-01-01

    This series provides a comprehensive review of the latest research results in quantitative nondestructive evaluation (NDE). Leading investigators working in government agencies, major industries, and universities present a broad spectrum of work extending from basic research to early engineering applications. An international assembly of noted authorities in NDE thoroughly cover such topics as: elastic waves, guided waves, and eddy-current detection, inversion, and modeling; radiography and computed tomography, thermal techniques, and acoustic emission; laser ultrasonics, optical methods, and microwaves; signal processing and image analysis and reconstruction, with an emphasis on interpretation for defect detection; and NDE sensors and fields, both ultrasonic and electromagnetic; engineered materials and composites, bonded joints, pipes, tubing, and biomedical materials; linear and nonlinear properties, ultrasonic backscatter and microstructure, coatings and layers, residual stress and texture, and constructi...

  6. Nondestructive control of materials by ultrasonic tests

    International Nuclear Information System (INIS)

    Mercier, Noelle.

    1974-01-01

    A bibliographic study of nondestructive control methods of solids by ultrasonic tests, and of the ultrasonic emission of a transducer of finite dimension, is first presented. The principle of two of these methods is verified experimentally; they should permit the measurement of various physical parameters of solids, and the detection of local inhomogeneities. The first method calls upon the analysis of the ultrasonic signal (amplitude and phase), after it has crossed a constant thickness of a metallic specimen. This analysis reveals variations of attenuation and of ultrasonic propagation velocity within the specimen. A good spatial resolution is obtained by using 1mm-diameter probes. The second method leads, thanks to a test rig equipped with broad frequency band electrostatic transducers, to the knowledge of the attenuation law of the specimens as a function of frequency (present range: 5 to 15MHz); from this a classification of these specimens as regards their granulometry is deduced [fr

  7. Expert system technology for nondestructive waste assay

    International Nuclear Information System (INIS)

    Becker, G.K.; Determan, J.C.

    1998-01-01

    Nondestructive assay waste characterization data generated for use in the National TRU Program must be of known and demonstrable quality. Each measurement is required to receive an independent technical review by a qualified expert. An expert system prototype has been developed to automate waste NDA data review of a passive/active neutron drum counter system. The expert system is designed to yield a confidence rating regarding measurement validity. Expert system rules are derived from data in a process involving data clustering, fuzzy logic, and genetic algorithms. Expert system performance is assessed against confidence assignments elicited from waste NDA domain experts. Performance levels varied for the active, passive shielded, and passive system assay modes of the drum counter system, ranging from 78% to 94% correct classifications

  8. Nondestructive evaluation ultrasonic methods for construction materials

    International Nuclear Information System (INIS)

    Chilibon, I.; Zisu, T.; Raetchi, V.

    2002-01-01

    The paper presents some ultrasonic methods for evaluation of physical-mechanical properties of construction materials (bricks, concrete, BCA), such as: pulse method, examination methods, and direct measurement of the propagation velocity and impact-echo method. Utilizing these nondestructive evaluation ultrasonic methods it can be determined the main material parameters and material characteristics (elasticity coefficients, density, propagation velocity, ultrasound attenuation, etc.) of construction materials. These method are suitable for construction materials because the defectoscopy methods for metallic materials cannot be utilized, due to its rugged and non-homogeneous structures and grate attenuation coefficients of ultrasound propagation through materials. Also, the impact-echo method is a technique for flaw detection in concrete based on stress wave propagation. Studies have shown that the impact-echo method is effective for locating voids, honeycombing, delaminating, depth of surface opening cracks, and measuring member thickness

  9. Nondestructive evaluation of nuclear-grade graphite

    Science.gov (United States)

    Kunerth, D. C.; McJunkin, T. R.

    2012-05-01

    The material of choice for the core of the high-temperature gas-cooled reactors being developed by the U.S. Department of Energy's Next Generation Nuclear Plant Program is graphite. Graphite is a composite material whose properties are highly dependent on the base material and manufacturing methods. In addition to the material variations intrinsic to the manufacturing process, graphite will also undergo changes in material properties resulting from radiation damage and possible oxidation within the reactor. Idaho National Laboratory is presently evaluating the viability of conventional nondestructive evaluation techniques to characterize the material variations inherent to manufacturing and in-service degradation. Approaches of interest include x-ray radiography, eddy currents, and ultrasonics.

  10. Passive nondestructive assay of nuclear materials

    International Nuclear Information System (INIS)

    Reilly, D.; Ensslin, N.; Smith, H. Jr.; Kreiner, S.

    1991-03-01

    The term nondestructive assay (NDA) is applied to a series of measurement techniques for nuclear fuel materials. The techniques measure radiation induced or emitted spontaneously from the nuclear material; the measurements are nondestructive in that they do not alter the physical or chemical state of the nuclear material. NDA techniques are characterized as passive or active depending on whether they measure radiation from the spontaneous decay of the nuclear material or radiation induced by an external source. This book emphasizes passive NDA techniques, although certain active techniques like gamma-ray absorption densitometry and x-ray fluorescence are discussed here because of their intimate relation to passive assay techniques. The principal NDA techniques are classified as gamma-ray assay, neutron assay, and calorimetry. Gamma-ray assay techniques are treated in Chapters 1--10. Neutron assay techniques are the subject of Chapters 11--17. Chapters 11--13 cover the origin of neutrons, neutron interactions, and neutron detectors. Chapters 14--17 cover the theory and applications of total and coincidence neutron counting. Chapter 18 deals with the assay of irradiated nuclear fuel, which uses both gamma-ray and neutron assay techniques. Chapter 19 covers perimeter monitoring, which uses gamma-ray and neutron detectors of high sensitivity to check that no unauthorized nuclear material crosses a facility boundary. The subject of Chapter 20 is attribute and semiquantitative measurements. The goal of these measurements is a rapid verification of the contents of nuclear material containers to assist physical inventory verifications. Waste and holdup measurements are also treated in this chapter. Chapters 21 and 22 cover calorimetry theory and application, and Chapter 23 is a brief application guide to illustrate which techniques can be used to solve certain measurement problems

  11. A stereological study of the mediodorsal thalamic nucleus in Down syndrome

    DEFF Research Database (Denmark)

    Karlsen, A S; Korbo, S; Uylings, H B M

    2014-01-01

    The total number of neurons and glial cells in the mediodorsal thalamic (MDT) nucleus of four aged females with Down syndrome (DS; mean age 69years) was estimated and compared to six age- and sex-matched controls. The MDT nucleus was delineated on coronal sections, and cell numbers (large and small...

  12. Thick methacrylate sections devoid of lost caps simplify stereological quantifications based on the optical fractionator design

    DEFF Research Database (Denmark)

    Andersen, Stine Hasselholt; Lykkesfeldt, Jens; Larsen, Jytte Overgaard

    2015-01-01

    Abstract In neuroscience, the optical fractionator technique is frequently used for unbiased cell number estimations. Although unbiased in theory, the practical application of the technique is often biased by the necessity of introducing a guard zone at one side of the disector to counter lost caps...

  13. A novel application for the cavalieri principle: a stereological and methodological study.

    Science.gov (United States)

    Altunkaynak, Berrin Zuhal; Altunkaynak, Eyup; Unal, Deniz; Unal, Bunyamin

    2009-08-01

    The Cavalieri principle was applied to consecutive pathology sections that were photographed at the same magnification and used to estimate tissue volumes via superimposing a point counting grid on these images. The goal of this study was to perform the Cavalieri method quickly and practically. In this study, 10 adult female Sprague Dawley rats were used. Brain tissue was removed and sampled both systematically and randomly. Brain volumes were estimated using two different methods. First, all brain slices were scanned with an HP ScanJet 3400C scanner, and their images were shown on a PC monitor. Brain volume was then calculated based on these images. Second, all brain slices were photographed in 10× magnification with a microscope camera, and brain volumes were estimated based on these micrographs. There was no statistically significant difference between the volume measurements of the two techniques (P>0.05; Paired Samples t Test). This study demonstrates that personal computer scanning of serial tissue sections allows for easy and reliable volume determination based on the Cavalieri method.

  14. Nondestructive nuclear measurement in the fuel cycle. Part 2

    International Nuclear Information System (INIS)

    Lyoussi, A.

    2005-01-01

    Nondestructive measurement techniques are today widely used in practically all steps of the fuel cycle. This article is devoted to the presentation of the control and characterization needs and to the main active nondestructive nuclear methods used: 1 - main active nondestructive nuclear measurement methods: active neutronic measurement (needs and motivations, physical principle, measurement of delayed neutrons following a continuous irradiation, measurement of prompt neutrons (differential die-away technique - DDT), measurement of prompt and delayed neutrons (Sphincs method), neutronic method coupled to gamma spectroscopy), measurement by induced photo-fissions (needs and motivations, physical principle); 2 - conclusion. (J.S.)

  15. Proceedings CORENDE: Regional congress on nondestructive and structural evaluation

    International Nuclear Information System (INIS)

    1997-01-01

    Works are presented at the CORENDE: Regional Congress on Nondestructive and Structural Evaluation organized by the National Atomic Energy Commission and the National Technological University (Mendoza). This congress wants to be the forum where people from research, industry and marketing might meet and discuss ideas towards the fostering of these new cultural habits. Papers covering all disciplines contributing to the evaluation of components, systems and structures are welcome: nondestructive evaluation methods and techniques (ultrasound, eddy currents and other electromagnetic methods, acoustic emission, radiography, thermography, leak testing, dye-penetrants, visual inspection, etc.), personnel certification, welding inspection, nondestructive metallography, optics and lasers, fluid-structure interaction, vibrations, extensometry, modelling of structures [es

  16. Modelling, simulation and visualisation for electromagnetic non-destructive testing

    International Nuclear Information System (INIS)

    Ilham Mukriz Zainal Abidin; Abdul Razak Hamzah

    2010-01-01

    This paper reviews the state-of-the art and the recent development of modelling, simulation and visualization for eddy current Non-Destructive Testing (NDT) technique. Simulation and visualization has aid in the design and development of electromagnetic sensors and imaging techniques and systems for Electromagnetic Non-Destructive Testing (ENDT); feature extraction and inverse problems for Quantitative Non-Destructive Testing (QNDT). After reviewing the state-of-the art of electromagnetic modelling and simulation, case studies of Research and Development in eddy current NDT technique via magnetic field mapping and thermography for eddy current distribution are discussed. (author)

  17. Nondestructive evaluation using dipole model analysis with a scan type magnetic camera

    Science.gov (United States)

    Lee, Jinyi; Hwang, Jiseong

    2005-12-01

    Large structures such as nuclear power, thermal power, chemical and petroleum refining plants are drawing interest with regard to the economic aspect of extending component life in respect to the poor environment created by high pressure, high temperature, and fatigue, securing safety from corrosion and exceeding their designated life span. Therefore, technology that accurately calculates and predicts degradation and defects of aging materials is extremely important. Among different methods available, nondestructive testing using magnetic methods is effective in predicting and evaluating defects on the surface of or surrounding ferromagnetic structures. It is important to estimate the distribution of magnetic field intensity for applicable magnetic methods relating to industrial nondestructive evaluation. A magnetic camera provides distribution of a quantitative magnetic field with a homogeneous lift-off and spatial resolution. It is possible to interpret the distribution of magnetic field when the dipole model was introduced. This study proposed an algorithm for nondestructive evaluation using dipole model analysis with a scan type magnetic camera. The numerical and experimental considerations of the quantitative evaluation of several sizes and shapes of cracks using magnetic field images of the magnetic camera were examined.

  18. Nondestructive web thickness measurement of micro-drills with an integrated laser inspection system

    Science.gov (United States)

    Chuang, Shui-Fa; Chen, Yen-Chung; Chang, Wen-Tung; Lin, Ching-Chih; Tarng, Yeong-Shin

    2010-09-01

    Nowadays, the electric and semiconductor industries use numerous micro-drills to machine micro-holes in printed circuit boards. The measurement of web thickness of micro-drills, a key parameter of micro-drill geometry influencing drill rigidity and chip-removal ability, is quite important to ensure quality control. Traditionally, inefficiently destructive measuring method is adopted by inspectors. To improve quality and efficiency of the web thickness measuring tasks, a nondestructive measuring method is required. In this paper, based on the laser micro-gauge (LMG) and laser confocal displacement meter (LCDM) techniques, a nondestructive measuring principle of web thickness of micro-drills is introduced. An integrated laser inspection system, mainly consisting of a LMG, a LCDM and a two-axis-driven micro-drill fixture device, was developed. Experiments meant to inspect web thickness of micro-drill samples with a nominal diameter of 0.25 mm were conducted to test the feasibility of the developed laser inspection system. The experimental results showed that the web thickness measurement could achieve an estimated repeatability of ± 1.6 μm and a worst repeatability of ± 7.5 μm. The developed laser inspection system, combined with the nondestructive measuring principle, was able to undertake the web thickness measuring tasks for certain micro-drills.

  19. Fatigue crack growth monitoring: fracture mechanics and non-destructive testing requirements

    International Nuclear Information System (INIS)

    Williams, S.; Mudge, P.J.

    1982-01-01

    If a fatigue crack is found in a component in service, two options exist if plant integrity is to be maintained: first, the plant can be removed from service and repairs effected or replacements fitted; second, the growth of the crack can be monitored non-destructively until it is either considered to be too large to tolerate, in which case it must be repaired, or until a convenient down time when repair can be effected. The second option has obvious benefits for plant operators, but in such a situation it is essential that errors of the non-destructive estimate of defect size, which will undoubtedly exist, and uncertainties in the fatigue crack growth laws in operation must both be allowed for if a safe extension of service life is to be obtained; i.e. without failure by leakage or fast fracture arising from the fatigue crack. This paper analyses the accuracy required of non-destructive crack measurement techniques to permit the safe monitoring of crack growth by periodic inspection. It then demonstrates that it is possible to achieve adequate crack monitoring using conventional ultrasonic techniques. (author)

  20. A fracture mechanics and reliability based method to assess non-destructive testings for pressure vessels

    International Nuclear Information System (INIS)

    Kitagawa, Hideo; Hisada, Toshiaki

    1979-01-01

    Quantitative evaluation has not been made on the effects of carrying out preservice and in-service nondestructive tests for securing the soundness, safety and maintainability of pressure vessels, spending large expenses and labor. Especially the problems concerning the time and interval of in-service inspections lack the reasonable, quantitative evaluation method. In this paper, the problems of pressure vessels are treated by having developed the analysis method based on reliability technology and probability theory. The growth of surface cracks in pressure vessels was estimated, using the results of previous studies. The effects of nondestructive inspection on the defects in pressure vessels were evaluated, and the influences of many factors, such as plate thickness, stress, the accuracy of inspection and so on, on the effects of inspection, and the method of evaluating the inspections at unequal intervals were investigated. The analysis of reliability taking in-service inspection into consideration, the evaluation of in-service inspection and other affecting factors through the typical examples of analysis, and the review concerning the time of inspection are described. The method of analyzing the reliability of pressure vessels, considering the growth of defects and preservice and in-service nondestructive tests, was able to be systematized so as to be practically usable. (Kako, I.)

  1. Development of nondestructive measurement of cold work rate, (2)

    International Nuclear Information System (INIS)

    Kamimura, Hideaki; Igarashi, Miyuki; Satoh, Masakazu; Miura, Makoto

    1978-01-01

    Cold-worked type 316 stainless steel will be used as fuel cladding material for the proto-type fast reactor MONJU. Cold work rate is an important parameter in swelling behavior of fuel cladding. It has been shown that austenitic stainless steel undergoes martensitic transformation during cold working. Nondestructive evaluation of cold work rate will be expected by measuring residual magnetism produced in the presence of martensitic phase when cold worked austenitic stainless steel is magnetized. In the previous work, the residual magnetism of cladding tubes of type 316 stainless steel was measured. The results have shown high degree of the correlation between residual magnetism and cold work rate. This paper reports the results of measurement on cold-rolled type 316 stainless steel plate samples. Dimensions of the specimens are 100 mm long and 3.5 and 7 mm wide. The apparatus and experimental procedures were similar to the previous work. Good agreement was found between the estimated cold work rate obtained in the previous work and that for cold rolled plate specimens. Measurement of residual magnetism in identical direction with magnetization showed smaller dispersion of data as compared with that in transverse direction. The residual magnetism near specimen surface hardly decreased when the surface of specimen was chemically removed. The reason for the comparative decrease in residual magnetism at 10% and 15% cold work rate is not clear. (Wakatsuki, Y.)

  2. Stereological study on the effect of vitamin C in preventing the adverse effects of bisphenol A on rat ovary

    Directory of Open Access Journals (Sweden)

    Malek Soleimani Mehranjani

    2016-06-01

    Full Text Available Background: Bisphenol A (BPA, an environmental pollutant, can generate free radicals which damages the reproductive system. Vitamin C is an antioxidant which may prevent the adverse effects of free radicals. Objective: The aim was to investigate the effect of vitamin C on the ovary tissue in rats treated with BPA. Materials and Methods: In this experimental study, 24 female Wistar rats (200±20 gr were randomly divided into 4 groups (n=6: control, BPA (60 μg/Kg/day, vitamin C (150 mg/Kg/day and BPA + vitamin C and orally treated for 20 days. The left ovaries were taken out, fixed for tissue processing and studied using stereological methods. Data were analyzed with SPSS using one-way ANOVA, and the means were considered significantly different at (p<0.05. Results: The total volume of ovary and cortex (p<0.01, medulla (p<0.05, the volume of corpus luteum (p<0.001 and the mean number of antral follicles (p<0.001 significantly reduced in BPA group compared with control, while the number of atretic follicles increased (p<0.05. The volume of oocyte (p<0.01 and its nucleus (p<0.001 in the antral follicles and the thickness of zona pellucida (ZP in the secondary (p<0.05 and antral (p<0.001 follicles significantly decreased in BPA group compared with controls. The above parameters in the BPA + vitamin C group were compensated to control level. Conclusion: Vitamin C can be used as a potential antioxidant in the case of BPA toxication

  3. Oogenesis, fecundity and condition of Baltic herring (Clupea harengus L.): A stereological study

    DEFF Research Database (Denmark)

    Bucholtz, R. Hagstrøm; Tomkiewicz, J.; Nyengaard, Jens Randel

    2013-01-01

    Herring (Clupea harengus) is a capital breeder that stores energy reserves in muscle tissue. Individual potential fecundity relies on the size and weight of female fish. Poor condition during the maturation process can lead to a heavy down-regulation of fecundity through atresia and, in the extre...... was a good predictor of potential fecundity within maturing stages of females. Combined with estimates of skipped spawning, this ovary weight could be used to estimate egg production thereby improving Central Baltic herring stock-recruitment models.......-regulation of fecundity. Although determined as spring spawners by otolith hatch type, 15% of the randomly sampled females were characterized by oocytes in CA stage in the prespawning period, indicating skipped spawning. The condition of these females was poor, which might have resulted in skipped spawning. Ovary weight......Herring (Clupea harengus) is a capital breeder that stores energy reserves in muscle tissue. Individual potential fecundity relies on the size and weight of female fish. Poor condition during the maturation process can lead to a heavy down-regulation of fecundity through atresia and, in the extreme...

  4. Nondestructive hall coefficient measurements using ACPD techniques

    Science.gov (United States)

    Velicheti, Dheeraj; Nagy, Peter B.; Hassan, Waled

    2018-04-01

    Hall coefficient measurements offer great opportunities as well as major challenges for nondestructive materials characterization. The Hall effect is produced by the magnetic Lorentz force acting on moving charge carriers in the presence of an applied magnetic field. The magnetic perturbation gives rise to a Hall current that is normal to the conduction current but does not directly perturb the electric potential distribution. Therefore, Hall coefficient measurements usually exploit the so-called transverse galvanomagnetic potential drop effect that arises when the Hall current is intercepted by the boundaries of the specimen and thereby produce a measurable potential drop. In contrast, no Hall potential is produced in a large plate in the presence of a uniform normal field at quasi-static low frequencies. In other words, conventional Hall coefficient measurements are inherently destructive since they require cutting the material under tests. This study investigated the feasibility of using alternating current potential drop (ACPD) techniques for nondestructive Hall coefficient measurements in plates. Specifically, the directional four-point square-electrode configuration is investigated with superimposed external magnetic field. Two methods are suggested to make Hall coefficient measurements in large plates without destructive machining. At low frequencies, constraining the bias magnetic field can replace constraining the dimensions of the specimen, which is inherently destructive. For example, when a cylindrical permanent magnet is used to provide the bias magnetic field, the peak Hall voltage is produced when the diameter of the magnet is equal to the diagonal of the square ACPD probe. Although this method is less effective than cutting the specimen to a finite size, the loss of sensitivity is less than one order of magnitude even at very low frequencies. In contrast, at sufficiently high inspection frequencies the magnetic field of the Hall current induces a

  5. Practical Uses of Neutron Radiography for Non-Destructive Testing

    International Nuclear Information System (INIS)

    Middleton, M.F.; de Beer, F.; Pazsit, Imre; Li, Kewen; Hilson, Jodie

    2006-01-01

    ). An acknowledged shortcoming of neutron radiography is its inability to identify structural features less than about 10 microns, which is largely a result of current limitations in neutron-image detection media. Many industries, such as the petroleum industry, for example, have been slow to adopt neutron radiography technology, preferring to persist with X-ray CT-scanning techniques, despite some obvious advantages held by neutron radiography. Historically, the principal problem with the slow adoption of neutron radiography, and tomography, appears to be related to (1) a lack of detailed studies demonstrating its power as an analytical technique, and (2) the restriction of neutron testing techniques to nuclear beams at reactors. Neutron radiography can provide a very accurate estimate of hydrogen content in porous media. In terms of non-destructive analysis of porous media, it is convenient to approach quantitative analysis of neutron images using the general rule: I = I 0 e - μρh (1) where I is the incident neutron intensity, I 0 is the transmitted neutron intensity, μ is the neutron attenuation coefficient in g/cm 2 , ρ is the sample density in g/cm 3 and h is the sample thickness (cm) in the direct path of neutron transmission. It has been found in recently reported investigations that equation [1] does not exactly describe the attenuation behaviour of neutrons for relatively large thicknesses of media, which are high neutron scatterers (e.g. hydrogen and hydrogen-rich media like water and oil). Thus, in our experiments, to ensure an accuracy as high as possible in the determination of hydrogen content, we have corrected the neutron transmission for scattering losses by a method suggested by Middleton and de Beer. Porosity of porous media can be derived from neutron images, using a simple extension of equation [1]. Figure 1 shows an hypothetical composite porous medium, consisting of two media (type 1 and type 2). Based on equation [1], equations [2) to [5

  6. Design-based stereological analysis of the lung parenchymal architecture and alveolar type II cells in surfactant protein A and D double deficient mice

    DEFF Research Database (Denmark)

    Jung, A; Allen, L; Nyengaard, Jens Randel

    2005-01-01

    Alveolar epithelial type II cells synthesize and secrete surfactant. The surfactant-associated proteins A and D (SP-A and SP-D), members of the collectin protein family, participate in pulmonary immune defense, modulation of inflammation, and surfactant metabolism. Both proteins are known to have......, but the mean volume of a single lamellar body remains constant. These results demonstrate that chronic deficiency of SP-A and SP-D in mice leads to parenchymal remodeling, type II cell hyperplasia and hypertrophy, and disturbed intracellular surfactant metabolism. The design-based stereological approach...

  7. An Intelligent Tutoring System for Nondestructive Testing Training

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. K.; Koh, S. N. [Joong Ang Inspection Co., Seoul (Korea, Republic of); Kim, M. K.; Shim, Y. J. [Ajou University, Suwon (Korea, Republic of)

    1998-02-15

    This paper is written to introduce a multimedia tutoring system for nondestructive testing using personal computer. Nondestructive testing, one of the chief methods for inspecting welds and many other components, is very difficult for the NDT inspectors to understand its technical basis without a wide experience. And it is necessary for considerable repeated education and training for keeping their knowledge. The tutoring system that can simulate NDT works is suggested to solve the above problem based on reasonable condition. The tutoring system shows basic theories of nondestructive testing in a book-style with video images and hyper-links, and it offers practices, in which users can simulate the testing equipment. The book-style and simulation practices provide effective and individual environments for learning nondestructive testing

  8. An Intelligent Tutoring System for Nondestructive Testing Training

    International Nuclear Information System (INIS)

    Kim, J. K.; Koh, S. N.; Kim, M. K.; Shim, Y. J.

    1998-01-01

    This paper is written to introduce a multimedia tutoring system for nondestructive testing using personal computer. Nondestructive testing, one of the chief methods for inspecting welds and many other components, is very difficult for the NDT inspectors to understand its technical basis without a wide experience. And it is necessary for considerable repeated education and training for keeping their knowledge. The tutoring system that can simulate NDT works is suggested to solve the above problem based on reasonable condition. The tutoring system shows basic theories of nondestructive testing in a book-style with video images and hyper-links, and it offers practices, in which users can simulate the testing equipment. The book-style and simulation practices provide effective and individual environments for learning nondestructive testing

  9. Advanced non-destructive methods for an efficient service performance

    International Nuclear Information System (INIS)

    Rauschenbach, H.; Clossen-von Lanken Schulz, M.; Oberlin, R.

    2015-01-01

    Due to the power generation industry's desire to decrease outage time and extend inspection intervals for highly stressed turbine parts, advanced and reliable Non-destructive methods were developed by Siemens Non-destructive laboratory. Effective outage performance requires the optimized planning of all outage activities as well as modern Non-destructive examination methods, in order to examine the highly stressed components (turbine rotor, casings, valves, generator rotor) reliably and in short periods of access. This paper describes the experience of Siemens Energy with an ultrasonic Phased Array inspection technique for the inspection of radial entry pinned turbine blade roots. The developed inspection technique allows the ultrasonic inspection of steam turbine blades without blade removal. Furthermore advanced Non-destructive examination methods for joint bolts will be described, which offer a significant reduction of outage duration in comparison to conventional inspection techniques. (authors)

  10. Use of nondestructive evaluation to detect moisture in flexible pavements.

    Science.gov (United States)

    2006-01-01

    The purpose of this study was to identify the currently available nondestructive evaluation technology that holds the greatest potential to detect moisture in flexible pavements and then apply the technology in multiple locations throughout Virginia....

  11. Long-Range Nondestructive Testing System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal is for the development of a long range, multi-point non-destructive system for the detection of subsurface flaws in metallic and composite materials of...

  12. Developing Raman spectroscopy for the nondestructive testing of composite materials.

    Science.gov (United States)

    2009-08-01

    The proposed research will develop the application of Raman Spectroscopy as a nondestructive evaluation tool for the condition assessment of carbon fiber composites. Composite materials are increasingly being used in engineered structures and compone...

  13. Fundamentals of passive nondestructive assay of fissionable material: laboratory workbook

    International Nuclear Information System (INIS)

    Reilly, T.D.; Augustson, R.H.; Parker, J.L.; Walton, R.B.; Atwell, T.L.; Umbarger, C.J.; Burns, C.E.

    1975-02-01

    This workbook is a supplement to LA-5651-M, ''Fundamentals of Passive Nondestructive Assay of Fissionable Material'' which is the text used during the Nondestructive Assay Training Session given by Group A-1 of the Los Alamos Scientific Laboratory. It contains the writeups used during the six laboratory sessions covering basic gamma-ray principles, quantitative gamma-ray measurements, uranium enrichment measurements, equipment holdup measurements, basic neutron principles, and quantitative neutron assay

  14. Qualification and certification of nondestructive testing personnel. Vol. 1

    Energy Technology Data Exchange (ETDEWEB)

    Aly, E A [Quality Assurance Department, national Center for Nuclear Safety and Radiation Control, Atomic Energy Authority, Cairo, (Egypt)

    1996-03-01

    Nondestructive testing and inspection are functions in achieving the goals of quality and efficiency at an acceptable cost. All quality assurance systems necessitate that engineers, technicians and craftsmen are able to demonstrate that they have the required level of knowledge and skill. This applies particularly to nondestructive testing (NDT) and inspection. The paper presented highlights most important national and international standards and guidelines addressing training, qualification and certification of NDT personnel.

  15. Fundamentals of passive nondestructive assay of fissionable material: laboratory workbook

    Energy Technology Data Exchange (ETDEWEB)

    Reilly, T.D.; Augustson, R.H.; Parker, J.L. Walton, R.B.; Atwell, T.L.; Umbarger, C.J.; Burns, C.E.

    1975-02-01

    This workbook is a supplement to LA-5651-M, ''Fundamentals of Passive Nondestructive Assay of Fissionable Material'' which is the text used during the Nondestructive Assay Training Session given by Group A-1 of the Los Alamos Scientific Laboratory. It contains the writeups used during the six laboratory sessions covering basic gamma-ray principles, quantitative gamma-ray measurements, uranium enrichment measurements, equipment holdup measurements, basic neutron principles, and quantitative neutron assay.

  16. Qualification and certification of nondestructive testing personnel. Vol. 1

    International Nuclear Information System (INIS)

    Aly, E.A.

    1996-01-01

    Nondestructive testing and inspection are functions in achieving the goals of quality and efficiency at an acceptable cost. All quality assurance systems necessitate that engineers, technicians and craftsmen are able to demonstrate that they have the required level of knowledge and skill. This applies particularly to nondestructive testing (NDT) and inspection. The paper presented highlights most important national and international standards and guidelines addressing training, qualification and certification of NDT personnel

  17. Summaries of the lectures of a conference on nondestructive testing

    International Nuclear Information System (INIS)

    1980-01-01

    The present brochure contains summaries of the lectures that were held at the DGZfP-conference on non-destructive testing' in May 1980 in Goettingen. The greater part of the lectures dealt with ultrasonic methods, electromagnetic methods and applications of X-, γ- and neutron-rays in non-destructive testing. Besides, questions of quality ensurance, economics and problems of the training of testing personnel were treated. (RW) [de

  18. A study of the effect of measurement error in predictor variables in nondestructive assay

    International Nuclear Information System (INIS)

    Burr, Tom L.; Knepper, Paula L.

    2000-01-01

    It is not widely known that ordinary least squares estimates exhibit bias if there are errors in the predictor variables. For example, enrichment measurements are often fit to two predictors: Poisson-distributed count rates in the region of interest and in the background. Both count rates have at least random variation due to counting statistics. Therefore, the parameter estimates will be biased. In this case, the effect of bias is a minor issue because there is almost no interest in the parameters themselves. Instead, the parameters will be used to convert count rates into estimated enrichment. In other cases, this bias source is potentially more important. For example, in tomographic gamma scanning, there is an emission stage which depends on predictors (the 'system matrix') that are estimated with error during the transmission stage. In this paper, we provide background information for the impact and treatment of errors in predictors, present results of candidate methods of compensating for the effect, review some of the nondestructive assay situations where errors in predictors occurs, and provide guidance for when errors in predictors should be considered in nondestructive assay

  19. Nondestructive assay methods for irradiated nuclear fuels

    International Nuclear Information System (INIS)

    Hsue, S.T.; Crane, T.W.; Talbert, W.L. Jr.; Lee, J.C.

    1978-01-01

    This report is a review of the status of nondestructive assay (NDA) methods used to determine burnup and fissile content of irradiated nuclear fuels. The gamma-spectroscopy method measures gamma activities of certain fission products that are proportional to the burnup. Problems associated with this method are migration of the fission products and gamma-ray attenuation through the relatively dense fuel material. The attenuation correction is complicated by generally unknown activity distributions within the assemblies. The neutron methods, which usually involve active interrogation and prompt or delayed signal counting, are designed to assay the fissile content of the spent-fuel elements. Systems to assay highly enriched spent-fuel assemblies have been tested extensively. Feasibility studies have been reported of systems to assay light-water reactor spent-fuel assemblies. The slowing-down spectrometer and neutron resonance absorption methods can distinguish between the uranium and plutonium fissile contents, but they are limited to the assay of individual rods. We have summarized the status of NDA techniques for spent-fuel assay and present some subjects in need of further investigation. Accuracy of the burnup calculations for power reactors is also reviewed

  20. Operation of the EPRI Nondestructive Evaluation Center

    International Nuclear Information System (INIS)

    Stone, R.M.; Ammirato, F.V.; Becker, F.L.

    1989-11-01

    This report describes the Electric Power Research Institute (EPRI) funded nondestructive evaluation (NDE) and life assessment project activities carried out at the EPRI NDE Center in 1988. The primary support for this program is provided through contract RP 1570-2 with the EPRI Nuclear Division. Supplementary funding is provided by other contracts with the EPRI Nuclear, Coal Combustion, and Electrical Systems Divisions. The major objective of this program is to provide improved and field-qualified NDE equipment, procedures, and personnel training to the electric utility industry. A second program objective involves the validation, provision, and maintenance of life assessment codes for selected plant components. Significant assistance has been provided to the utility industry under this project in the form of improved, field-ready equipment and procedures; critically needed assessments of inspection method capability; demonstrations of effectiveness of examination methods; rapid response for critical, short-term problems; assistance with selected life assessment computer codes; and training for specific utility industry needs. These efforts have specifically involved heat exchanger, piping, steam turbine, generator, and heavy section problems. Certain components of both nuclear and fossil plants have been addressed. 56 refs., 48 figs., 13 tabs

  1. A portable nondestructive assay measurement control system

    International Nuclear Information System (INIS)

    Palmer, M.E.

    1984-01-01

    Portable nondestructive assay (NDA) of plutonium processing hoods, solvent extraction columns, glove boxes, filters, and other items is required for both nuclear materials accountability and criticality control purposes. The Plutonium Finishing Plant has hundreds of such items that require routine portable NDA measurement. Previous recordkeeping of NDA measurements consisted of boxes of papers containing results and notebooks containing notes for each item to be measured. If the notes for any item were lost, new measurement parameters had to be calculated for that item. As a result, subsequent measurements could no longer be directly compared with previous results for that item due to possible changes in measurement parameters. The new portable NDA management system keeps all the necessary information in a computerized data base. Technicians are provided with a computer-generated drawing of each item to be measured, which also contains comments, measurement points, measurement parameters, and a form for filling in the raw data. After the measurements are made, the technician uses the computer to calculate and print out the results

  2. Magnetic Nondestructive Testing Techniques of Constructional Steel

    Directory of Open Access Journals (Sweden)

    Xiong Er-gang

    2016-01-01

    Full Text Available Steel is a kind of ferromagnetic material, which is extensively applied in such fields as buildings, bridges, railways, machines and lifeline engineering etc. Those engineering structures built of constructional steel will unavoidably experience some damages during their service lifetime, thus which will influence the distribution regularity of internal forces in structures, result in over-stresses, cause the local failure of structures, and even lead to collapse of the whole structure. Therefore, it is a pressing topic to study how to directly evaluate the real-time stressed states of structural members, damages and steel characteristics in present structural health monitoring and diagnosing fields. And the achievements of this research will be of theoretical significance and of application value of engineering. This paper summarizes varieties of new magnetic nondestructive testing techniques used in constructional steel, respectively investigates the testing principles, characteristics and application for the magnetic Barkhausen noise technique, magnetic acoustic emission technique, magnetic flux leakage technique, magnetic memory technique and magnetic absorption technique, and points out the problems present in the application of these new techniques to actual testing and the further research objective.

  3. Superconducting Quantum Interferometers for Nondestructive Evaluation

    Directory of Open Access Journals (Sweden)

    M. I. Faley

    2017-12-01

    Full Text Available We review stationary and mobile systems that are used for the nondestructive evaluation of room temperature objects and are based on superconducting quantum interference devices (SQUIDs. The systems are optimized for samples whose dimensions are between 10 micrometers and several meters. Stray magnetic fields from small samples (10 µm–10 cm are studied using a SQUID microscope equipped with a magnetic flux antenna, which is fed through the walls of liquid nitrogen cryostat and a hole in the SQUID’s pick-up loop and returned sidewards from the SQUID back to the sample. The SQUID microscope does not disturb the magnetization of the sample during image recording due to the decoupling of the magnetic flux antenna from the modulation and feedback coil. For larger samples, we use a hand-held mobile liquid nitrogen minicryostat with a first order planar gradiometric SQUID sensor. Low-Tc DC SQUID systems that are designed for NDE measurements of bio-objects are able to operate with sufficient resolution in a magnetically unshielded environment. High-Tc DC SQUID magnetometers that are operated in a magnetic shield demonstrate a magnetic field resolution of ~4 fT/√Hz at 77 K. This sensitivity is improved to ~2 fT/√Hz at 77 K by using a soft magnetic flux antenna.

  4. Proficiency Testing in Nondestructive Testing (NDT)

    International Nuclear Information System (INIS)

    Amry Amin Abbas; Suhairy Sani; Mohamad Pauzi Ismail; Abd Nassir Ibrahim

    2014-01-01

    Department of Standard Malaysia (DSM) launched myPTP programme on 31 December 2013 in accordance to ISO/IC 17043. The standard states the requirements for Proficiency Testing. The provider of these services is called Proficiency Testing Provider (PTP). The role of PTP is to compare the proficiency level between inspection bodies or laboratories. With the assistance of expert panel, the PTP will determine the assigned value as reference to be compared to the values obtained from the inspection bodies or laboratories. Quality wise, this services is important as participation will improve wuality of the inspection quality continuously and increase confidence level of client and improve safety level. Requirement of PT in NDT is mentioned in SC1.5- Specific Criteria for Accreditation of Mechanical Testing and Non-Destructive Testing (NDT) for MS ISO/IEC17025 and MTR2- MIBAS Technical Requirements for Accreditation of NDT. This paper explains and discusses the result of this proficiency test done on a number of NDT companies that participated. (author)

  5. Standard specification for agencies performing nondestructive testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This specification covers minimum requirements for agencies performing nondestructive testing (NDT). 1.2 When using this specification to assess the capability of, or to accredit NDT agencies, Guide E 1359 shall be used as a basis for the survey. It can be supplemented as necessary with more detail in order to meet the auditor's specific needs. 1.3 This specification can be used as a basis to evaluate testing or inspection agencies, or both, and is intended for use for the qualifying or accrediting, or both, of testing or inspection agencies, public or private. 1.4 The use of SI or inch-pound units, or combination thereof, will be the responsibility of the technical committee whose standards are referred to in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to...

  6. Feasibility of nondestructive assay measurements in uranium enrichment plants

    Energy Technology Data Exchange (ETDEWEB)

    Walton, R.B.

    1978-04-01

    Applications of nondestructive assay methods to measurement problems in uranium enrichment facilities are reviewed. The results of a number of test and evaluation projects that were performed over the last decade at ORGDP and Portsmouth are presented. Measurements of the residual holdup in the top enrichment portion of the shut-down K-25 cascade were made with portable neutron and gamma-ray detectors, and inventory estimates based on these data were in good agreement with ORGDP estimates. In the operating cascade, the tests showed that portable NaI detectors are effective for monitoring NaF and alumina media for gaseous effluent traps and that gas phase enrichments and inventories, as well as large deposits of uranium, can be detected with portable neutron and gamma-ray instrumentation. A wide variety of scrap and waste materials, including barrier and compressor blades, incinerator ash and trapping media, and miscellaneous waste, were measured using passive gamma-ray and neutron methods and 14-MeV neutron interrogation. Methods developed for rapid verification of UF/sub 6/ in shipping containers with portable neutron and gamma-ray instruments are now used routinely by safeguards inspectors. Passive assay methods can also be used to measure continuously the enrichments of /sup 235/U and /sup 234/U in the UF/sub 6/ product and tails withdrawals of a gaseous diffusion plant. A system that was developed and installed in the extended-range product withdrawal station of the Portsmouth facility measures enrichment with a relative accuracy of 0.5%. A stand-alone neutron detector has also been successfully evaluated for the measurement of the isotopic abundance of /sup 234/U in UF/sub 6/ in sample cylinders, an application of potential importance to Minor Isotope Safeguards Technology. Recommendations are made on the role of NDA measurements for enrichment plant safeguards, including additional tests and evaluations that may be needed, particularly for advanced uranium

  7. Protective effect of Brewer's yeast on methimazole-induced-adrenal atrophy (a stereological study).

    Science.gov (United States)

    Dehghani, Farzaneh; Zabolizadeh, Jamal; Noorafshan, Ali; Panjehshahin, Mohammad Reza; Karbalay-Doust, Saied

    2010-04-20

    Induction of hypothyroidism by thioamide drugs will cause adrenal gland atrophy and decrease in its hormones. To prevent side effect on the adrenal gland, brewer's yeast, a natural product rich in vitamins and minerals was used. Serological techniques were applied to measure the volume of adrenal gland. For this purpose, 48 Sprague-Dawley rats were randomly divided into one control and three experimental groups. In group 1, methimazole was administered at the dose of 30 mg/kg/day days, in group 2, 120 mg/kg/day of, brewer's yeast, in group 3, 30 mg/kg/day of methimazole plus 120 mg/kg/day of brewer yeast, and for the control group, an equal volume of saline (0.5 ml/rat/day) was orally given. After 30 days, all the animals were anesthetized and their adrenal glands were removed, fixed, embedded and stained. The volume of different zones of the adrenal glands was estimated by Cavalieri principle and point counting methods. statistical analysis was performed using Mann-Withney test and p Brewer's yeast reduced the methimazole side effects on this zone. In conclusion, it seems that the use of brewer's yeast could prevent methimazole-induced atrophy of the adrenal gland.

  8. A stereological approach for measuring the groove angles of intergranular corrosion

    International Nuclear Information System (INIS)

    Gwinner, B.; Borgard, J.-M.; Dumonteil, E.; Zoia, A.

    2017-01-01

    Highlights: • The ICG morphology has been characterized in 3D by X-ray μ-tomography. • The measurement of the angles of the IGC groove on 2D cross sections induces a bias. • A methodology is proposed to estimate the true value of the IGC groove angles in 3D. - Abstract: Non-sensitized austenitic stainless steels can be prone to intergranular corrosion when they are in contact with an oxidizing medium like nitric acid. Intergranular corrosion is characterized by the formation of grooves along the grain boundaries. The angle of these grooves is a key parameter, which directly informs of the intergranular corrosion kinetics. Most of the time, the angles of the grooves are experimentally measured on 2-dimensional cross sections of the corroded samples. This study discusses the relationship between the groove angle measured on 2-dimensional sections and the true groove angle in 3-dimensional space. This approach could also be easily extended to the study of crack angle in the domains of corrosion-fatigue, stress corrosion cracking or mechanical fracture.

  9. Nondestructive Determination of Reinforcement Volume Fractions in Particulate Composites : Ultrasonic Method

    International Nuclear Information System (INIS)

    Jeong, Hyun Jo

    1998-01-01

    A nondestructive ultrasonic technique is presented for estimating the reinforcement volume fractions of particulate composites. The proposed technique employs a theoretical model which accounts for composite microstructures, together with a measurement of ultrasonic velocity to determine the reinforcement volume fractions. The approach is used for a wide range of SiC particulate reinforced Al matrix (SiC p /AI) composites. The method is considered to be reliable in determining the reinforcement volume fractions. The technique could be adopted in a production unit for the quality assessment of the metal matrix particulate composite extrusions

  10. Nondestructive assay of subassemblies of various spent or fresh fuels by active neutron interrogation

    International Nuclear Information System (INIS)

    Ragan, G.L.; Ricker, C.W.; Chiles, M.M.; Ingersoll, D.T.; Slaughter, G.G.

    1979-01-01

    Recent studies show that subassemblies containing various spent fuels could be assayed rapidly and accurately by a nondestructive assay system using active neutron interrogation and prompt-neutron detection. Subassembly penetration is achieved by 24-keV (Sb--Be) interrogation neutrons; the spent-fuel neutron background is overridden by using strong interrogating sources and prompt-neutron signals, and background gammas are absorbed by lead. Experiments have demonstrated the potential for assaying with better than 5% accuracy, three spent plutonium-fueled subassemblies per hour. Calculations, validated by experiments, predict even better performance for fresh or uranium-fueled subassemblies; several performance estimates are given

  11. Photosynthetic bark: use of chlorophyll absorption continuum index to estimate Boswellia papyrifera bark chlorophyll content

    NARCIS (Netherlands)

    Girma, A.; Skidmore, A.K.; Bie, de C.A.J.M.; Bongers, F.; Schlerf, M.

    2013-01-01

    Quantification of chlorophyll content provides useful insight into the physiological performance of plants. Several leaf chlorophyll estimation techniques, using hyperspectral instruments, are available. However, to our knowledge, a non-destructive bark chlorophyll estimation technique is not

  12. Photosynthetic bark : use of chlorophyll absorption continuum index to estimate Boswellia papyrifera bark chlorophyll content

    NARCIS (Netherlands)

    Girma Gebrekidan, A.; Skidmore, A.K.; de Bie, C.A.J.M.; Bongers, Frans; Schlerf, Martin; Schlerf, M.

    2013-01-01

    Quantification of chlorophyll content provides useful insight into the physiological performance of plants. Several leaf chlorophyll estimation techniques, using hyperspectral instruments, are available. However, to our knowledge, a non-destructive bark chlorophyll estimation technique is not

  13. Long live the liver: immunohistochemical and stereological study of hepatocytes, liver sinusoidal endothelial cells, Kupffer cells and hepatic stellate cells of male and female rats throughout ageing.

    Science.gov (United States)

    Marcos, Ricardo; Correia-Gomes, Carla

    2016-12-01

    Male/female differences in enzyme activity and gene expression in the liver are known to be attenuated with ageing. Nevertheless, the effect of ageing on liver structure and quantitative cell morphology remains unknown. Male and female Wistar rats aged 2, 6, 12 and 18 months were examined by means of stereological techniques and immunohistochemical tagging of hepatocytes (HEP), liver sinusoidal endothelial cells (LSEC), Kupffer cells (KC) and hepatic stellate cells (HSC) in order to assess the total number and number per gram of these cells throughout life. The mean cell volume of HEP and HSC, the lobular position and the collagen content of the liver were also evaluated with stereological techniques. The number per gram of HSC was similar for both genders and was maintained throughout ageing. The mean volume of HSC was also conserved but differences in the cell body and lobular location were observed. Statistically significant gender differences in HEP were noted in young rats (females had smaller and more binucleated HEP) but were attenuated with ageing. The same occurred for KC and LSEC, since the higher number per gram in young females disappeared in older animals. Liver collagen increased with ageing but only in males. Thus, the numbers of these four cell types are related throughout ageing, with well-defined cell ratios. The shape and lobular position of HSC change with ageing in both males and females. Gender dimorphism in HEP, KC and LSEC of young rat liver disappears with ageing.

  14. Nondestructive testing of nuclear reactor components integrity

    International Nuclear Information System (INIS)

    Mala, M.; Miklos, M.

    2011-01-01

    Nuclear energy must respond to current challenges in the energy market. The significant parameters are increase of the nuclear fuel price, closed fuel cycle, reduction and safe and the final disposal of high level radioactive waste. Nowadays, the discussions on suitable energy mix are taking place not only here in Czech Republic, but also in many other European countries. It is necessary to establish an appropriate ratio among the production of electricity from conventional, nuclear and renewable energy sources. Also, it is necessary to find ways how to streamline the economy, central part of the nuclear fuel cycle and thereby to increase the competitiveness of nuclear energy. This streamlining can be carried out by improving utilization of existing nuclear fuel with maintaining a high degree of nuclear facilities safety. Increasing operational reliability and safety together with increasing utilization of nuclear fuel place increasing demands on monitoring of changes during fuel burnup. The potential fuel assembly damages in light water reactors are prevented by the introduction of new procedures and programs of the fuel assembly monitoring. One of them is the Post Irradiation Inspection Program (PIIP) which is a good tool for monitoring of chemical regime impact on the fuel assembly cladding behavior. Main nondestructive techniques that are used at nuclear power plants for the fuel assembly integrity evaluation are ultrasonic measurements, eddy current measurements, radiographic testing, acoustic techniques and others. Ultrasonic system is usual tool for leak fuel rod evaluation and it is also used at Temelin NPP. Since 2009, Temelin NPP has cooperated with Research Center Rez Ltd in frame of PIIP program at both units WWER 1000. This program was established for US VVantage6 fuel assemblies and also it continues for Russian TVSA-T fuel assemblies. (author)

  15. Nondestructive radioassay for waste management: an assessment

    Energy Technology Data Exchange (ETDEWEB)

    Lehmkuhl, G.D.

    1981-06-01

    Nondestructive Assay (NDA) for Transuranic Waste Management is used to mean determining the amount of transuranic (TRU) isotopes in crates, drums, boxes, cans, or other containers without having to open the container. It also means determining the amount of TRU in soil, bore holes, and other environmental testing areas without having to go through extensive laboratory wet chemistry analyses. it refers to radioassay techniques used to check for contamination on objects after decontamination and to determine amounts of TRU in waste processing streams without taking samples to a laboratory. Gednerally, NDA instrumentation in this context refers to all use of radioassay which does not involve taking samples and using wet chemistry techniques. NDA instruments have been used for waste assay at some sites for over 10 years and other sites are just beginning to consider assay of wastes. The instrumentation used at several sites is discussed in this report. Almost all these instruments in use today were developed for special nuclear materials safeguards purposes and assay TRU waste down to the 500 nCi/g range. The need for instruments to assay alpha particle emitters at 10 nCi/g or less has risen from the wish to distinguish between Low Level Waste (LLW) and TRU Waste at the defined interface of 10 nCi/g. Wastes have historically been handled as TRU wastes if they were just suspected to be transuranically contaminated but their exact status was unknown. Economic and political considerations make this practice undesirable since it is easier and less costly to handle LLW. This prompted waste generators to want better instrumentation and led the Transuranic Waste Management Program to develop and test instrumentation capable of assaying many types of waste at the 10 nCi/g level. These instruments are discussed.

  16. Nondestructive Examination Guidance for Dry Storage Casks

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Ryan M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Suffield, Sarah R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hirt, Evelyn H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Suter, Jonathan D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lareau, John P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhuge, Jing Wei [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Qiao, Hong [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Moran, Traci L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Ramuhalli, Pradeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-30

    In this report, an assessment of NDE methods is performed for components of NUHOMS 80 and 102 dry storage system components in an effort to assist NRC staff with review of license renewal applications. The report considers concrete components associated with the horizontal storage modules (HSMs) as well as metal components in the HSMs. In addition, the report considers the dry shielded canister (DSC). Scope is limited to NDE methods that are considered most likely to be proposed by licensees. The document, ACI 349.3R, Evaluation of Existing Nuclear Safety-Related Concrete Structures, is used as the basis for the majority of the NDE methods summarized for inspecting HSM concrete components. Two other documents, ACI 228.2R, Nondestructive Test Methods for Evaluation of Concrete in Structures, and ORNL/TM-2007/191, Inspection of Nuclear Power Plant Structure--Overview of Methods and Related Application, supplement the list with additional technologies that are considered applicable. For the canister, the ASME B&PV Code is used as the basis for NDE methods considered, along with currently funded efforts through industry (Electric Power Research Institute [EPRI]) and the U.S. Department of Energy (DOE) to develop inspection technologies for canisters. The report provides a description of HSM and DSC components with a focus on those aspects of design considered relevant to inspection. This is followed by a brief description of other concrete structural components such as bridge decks, dams, and reactor containment structures in an effort to facilitate comparison between these structures and HSM concrete components and infer which NDE methods may work best for certain HSM concrete components based on experience with these other structures. Brief overviews of the NDE methods are provided with a focus on issues and influencing factors that may impact implementation or performance. An analysis is performed to determine which NDE methods are most applicable to specific

  17. Non-destructive decontamination of building materials

    Science.gov (United States)

    Holecek, Josef; Otahal, Petr

    2015-11-01

    For nondestructive radiation decontamination of surfaces it is necessary to use varnishes, such as ARGONNE, DG1101, DG1108, etc. This text evaluates the use of manufactured strippable coatings for radiation decontamination. To evaluate decontamination capability of such coatings the following varnishes were selected and subsequently used: AZ 1-700 and AXAL 1807S. The varnishes were tested on different building materials surfaces contaminated by short-term radioisotopes of Na-24 or La-140, in water soluble or water insoluble forms. Decontamination quality was assessed by the decontamination efficiency value, defined as the proportion of removed activity to the applied activity. It was found that decontamination efficiency of both used varnishes depends not only on the form of contaminant, but in the case of application of AXAL 1807S varnish it also depends on the method of its application on the contaminated surface. The values of the decontamination efficiency for AZ1-700 varnish range from 46% for decontamination of a soluble form of the radioisotope from concrete surface to 98% for the decontamination of a soluble form of the radioisotope from ceramic tile surface. The decontamination efficiency values determined for AXAL 1807S varnish range from 48% for decontamination of a soluble form of the radioisotope from concrete surface to 96% for decontamination of an insoluble form of the radioisotope from ceramic tile surface. Comparing these values to the values given for the decontaminating varnishes we can conclude that AXAL 1807S varnish is possible to use on all materials, except highly porous materials, such as plasterboard or breeze blocks, or plastic materials. AZ 1-700 varnish can be used for all dry materials except plasterboard.

  18. Research process of nondestructive testing pitting corrosion in metal material

    Directory of Open Access Journals (Sweden)

    Bo ZHANG

    2017-12-01

    Full Text Available Pitting corrosion directly affects the usability and service life of metal material, so the effective nondestructive testing and evaluation on pitting corrosion is of great significance for fatigue life prediction because of data supporting. The features of pitting corrosion are elaborated, and the relation between the pitting corrosion parameters and fatigue performance is pointed out. Through introducing the fundamental principles of pitting corrosion including mainly magnetic flux leakage inspection, pulsed eddy current and guided waves, the research status of nondestructive testing technology for pitting corrosion is summarized, and the key steps of nondestructive testing technologies are compared and analyzed from the theoretical model, signal processing to industrial applications. Based on the analysis of the signal processing specificity of different nondestructive testing technologies in detecting pitting corrosion, the visualization combined with image processing and signal analysis are indicated as the critical problems of accurate extraction of pitting defect information and quantitative characterization for pitting corrosion. The study on non-contact nondestructive testing technologies is important for improving the detection precision and its application in industries.

  19. Evaluation of Nondestructive Assay/Nondestructive Examination Capabilities for Department of Energy Spent Nuclear Fuel

    International Nuclear Information System (INIS)

    Luptak, A.J.; Bulmahn, K.D.

    1998-01-01

    This report summarizes an evaluation of the potential use of nondestructive assay (NDA) and nondestructive examination (NDE) technologies on DOE spent nuclear fuel (SNF). It presents the NDA/NDE information necessary for the National Spent Nuclear Fuel Program (NSNFP) and the SNF storage sites to use when defining that role, if any, of NDA/NDE in characterization and certification processes. Note that the potential role for NDA/NDE includes confirmatory testing on a sampling basis and is not restricted to use as a primary, item-specific, data collection method. The evaluation does not attempt to serve as a basis for selecting systems for development or deployment. Information was collected on 27 systems being developed at eight DOE locations. The systems considered are developed to some degree, but are not ready for deployment on the full range of DOE SNF and still require additional development. The system development may only involve demonstrating performance on additional SNF, packaging the system for deployment, and developing calibration standards, or it may be as extensive as performing additional basic research. Development time is considered to range from one to four years. We conclude that NDA/NDE systems are capable of playing a key role in the characterization and certification of DOE SNF, either as the primary data source or as a confirmatory test. NDA/NDE systems will be able to measure seven of the nine key SNF properties and to derive data for the two key properties not measured directly. The anticipated performance goals of these key properties are considered achievable except for enrichment measurements on fuels near 20% enrichment. NDA/NDE systems can likely be developed to measure the standard canisters now being considered for co-disposal of DOE SNF. This ability would allow the preparation of DOE SNF for storage now and the characterization and certification to be finalize later

  20. Development of hotcell non-destructive examination techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Uhn; Yu, S. C.; Kang, B. S.; Byun, K. S. [Chungbuk National University, Chungju (Korea)

    2002-01-01

    The purpose of this project is to establish non-destructive examination techniques which needs to determine the status of spent nuclear fuel and/or bundles. Through the project, we will establish an image reconstruction tomography which is a kind of non-destructive techniques in Hotcell. The tomography technique can be used to identify the 2-dimensional density distribution of fission products in the spent fuel rods and/or bundles. And form results of the measurement and analysis of magnetic properties of neutron irradiated material in the press vessel and reactor, we will develop some techniques to test its hardness and defects. In 2001, the first year, we have established mathematical background and necessary data and informations to develop the techniques. We will try to find some experimental results that are necessary in developing the Hotcell non-destructive examination techniques in the coming year. 14 refs., 65 figs., 5 tabs. (Author)

  1. Nondestructive verification and assay systems for spent fuels

    International Nuclear Information System (INIS)

    Cobb, D.D.; Phillips, J.R.; Bosler, G.E.; Eccleston, G.W.; Halbig, J.K.; Hatcher, C.R.; Hsue, S.T.

    1982-04-01

    This is an interim report of a study concerning the potential application of nondestructive measurements on irradiated light-water-reactor (LWR) fuels at spent-fuel storage facilities. It describes nondestructive measurement techniques and instruments that can provide useful data for more effective in-plant nuclear materials management, better safeguards and criticality safety, and more efficient storage of spent LWR fuel. In particular, several nondestructive measurement devices are already available so that utilities can implement new fuel-management and storage technologies for better use of existing spent-fuel storage capacity. The design of an engineered prototype in-plant spent-fuel measurement system is approx. 80% complete. This system would support improved spent-fuel storage and also efficient fissile recovery if spent-fuel reprocessing becomes a reality

  2. Nondestructive characterization of low-level transuranic waste

    International Nuclear Information System (INIS)

    Barna, B.A.; Reinhardt, W.W.

    1981-10-01

    The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production waste characterization system

  3. Non-destructive testing and evaluation for structural integrity

    International Nuclear Information System (INIS)

    Baldev Raj; Jayakumar, T.; Rao, B.P.C.

    1995-01-01

    In this paper, a brief description of the physical concepts of non-destructive evaluation (NDE) methods and the physical/derived parameters that are used for assessing defects, stresses and microstructures are given. A few case studies highlighting the importance of non-destructive testing and evaluation for structural integrity assessment are also discussed based on the investigations carried out. Emerging concepts like intelligent processing of materials, expert systems, neural networks, use of multisensors with fusion of data and exploitation of signal analysis and imaging approaches are also addressed in this paper. (author). 92 refs., 1 tab

  4. Magnetic Non-destructive Testing of Plastically Deformed Mild Steel

    Directory of Open Access Journals (Sweden)

    Jozef Pala

    2004-01-01

    Full Text Available The Barkhausen noise analysis and coercive field measurement have been used as magnetic non-destructive testing methods for plastically deformed high quality carbon steel specimens. The strain dependence of root mean square value and power spectrum of the Barkhausen noise and the coercive field are explained in terms of the dislocation density. The specimens have been subjected to different magnetizing frequencies to show the overlapping nature of the Barkhausen noise. The results are discussed in the context of usage of magnetic non-destructive testing to evaluate the plastic deformation of high quality carbon steel products.

  5. Pattern recognition approach to nondestructive evaluation of materials

    International Nuclear Information System (INIS)

    Chen, C.H.

    1987-01-01

    In this paper, a pattern recognition approach to the ultrasonic nondestructive evaluation of materials is examined. Emphasis is placed on identifying effective features from time and frequency domains, correlation functions and impulse responses to classify aluminum plate specimens into three major defect geometry categories: flat, angular cut and circular hole defects. A multi-stage classification procedure is developed which can further determine the angles and sizes for defect characterization and classification. The research clearly demonstrates that the pattern recognition approach can significantly improve the nondestructive material evaluation capability of the ultrasonic methods without resorting to the solution of highly complex mathematical inverse problems

  6. Nondestructive evaluation of creep-fatigue damage: an interim report

    International Nuclear Information System (INIS)

    Nickell, R.E.

    1977-02-01

    In view of the uncertainties involved in designing against creep-fatigue failure and the consequences of such failures in Class 1 nuclear components that operate at elevated temperature, the possibility of intermittent or even continuous non-destructive examination of these components has been considered. In this interim report some preliminary results on magnetic force and ultrasonic evaluation of creep-fatigue damage in an LMFBR steam generator material are presented. These results indicate that the non-destructive evaluation of pure creep damage will be extremely difficult. A set of biaxial creep-fatigue tests that are designed to discriminate between various failure theories is also described

  7. Characterization of legacy low level waste at the Svafo facility using gamma non-destructive assay and X-ray non-destructive examination techniques - 59289

    International Nuclear Information System (INIS)

    Halliwell, Stephen; Mottershead, Gary; Ekenborg, Fredrik

    2012-01-01

    Document available in abstract form only. Full text of publication follows: Over 7000 drums containing legacy, low level radioactive waste are stored at four SVAFO facilities on the Studsvik site which is located near Nykoeping, Sweden. The vast majority of the waste drums (>6000) were produced between 1969 and 1979. The remainder were produced from 1980 onwards. Characterization of the waste was achieved using a combination of non-destructive techniques via mobile equipment located in the AU building at the Studsvik site. Each drum was weighed and a dose rate measurement was recorded. Gamma spectroscopy was used to measure and estimate radionuclide content. Real time xray examination was performed to identify such prohibited items as free liquids. (authors)

  8. A Monte Carlo approach applied to ultrasonic non-destructive testing

    Science.gov (United States)

    Mosca, I.; Bilgili, F.; Meier, T.; Sigloch, K.

    2012-04-01

    Non-destructive testing based on ultrasound allows us to detect, characterize and size discrete flaws in geotechnical and architectural structures and materials. This information is needed to determine whether such flaws can be tolerated in future service. In typical ultrasonic experiments, only the first-arriving P-wave is interpreted, and the remainder of the recorded waveform is neglected. Our work aims at understanding surface waves, which are strong signals in the later wave train, with the ultimate goal of full waveform tomography. At present, even the structural estimation of layered media is still challenging because material properties of the samples can vary widely, and good initial models for inversion do not often exist. The aim of the present study is to combine non-destructive testing with a theoretical data analysis and hence to contribute to conservation strategies of archaeological and architectural structures. We analyze ultrasonic waveforms measured at the surface of a variety of samples, and define the behaviour of surface waves in structures of increasing complexity. The tremendous potential of ultrasonic surface waves becomes an advantage only if numerical forward modelling tools are available to describe the waveforms accurately. We compute synthetic full seismograms as well as group and phase velocities for the data. We invert them for the elastic properties of the sample via a global search of the parameter space, using the Neighbourhood Algorithm. Such a Monte Carlo approach allows us to perform a complete uncertainty and resolution analysis, but the computational cost is high and increases quickly with the number of model parameters. Therefore it is practical only for defining the seismic properties of media with a limited number of degrees of freedom, such as layered structures. We have applied this approach to both synthetic layered structures and real samples. The former contributed to benchmark the propagation of ultrasonic surface

  9. Specific features of the determination of the pellet-cladding gap of the fuel rods by non-destructive method

    International Nuclear Information System (INIS)

    Amosov, S.V.; Pavlov, S.V.

    2002-01-01

    This report describes the specific features of determining the pellet-cladding gap of the irradiated WWER-1000 fuel rods by nondestructive method. The method is based on the elastic radial deformation of the cladding up to its contact with the fuel. The value of deformation of cladding till its contacting fuel when radial force changes from F max to 0 is proposed as a measuring parameter for determination of the diametrical gap. Because of the features of compression method, the obtained gap value is not analog of the gap measured on micrograph of the fuel rod cross-section. Results of metallography can provide only qualitative evaluation of its method efficiency. Comparison of the values determined by non-destructive method and metallography for WWER-1000 fuel rods with burnup from 25 to 55 MWd/kg U testified that the results of compression method can be used as a low estimate of the pellet-cladding gap value. (author)

  10. Nondestructive evaluation for sorting red maple logs

    Science.gov (United States)

    Xiping Wang; Robert J. Ross; David W. Green; Karl Englund; Michael Wolcott

    2000-01-01

    Existing log grading procedures in the United States make only visual assessments of log quality. These procedures do not incorporate estimates of the modulus of elasticity (MOE) of logs. It is questionable whether the visual grading procedures currently used for logs adequately assess the potential quality of structural products manufactured from them, especially...

  11. Artificial intelligence to maximise contributions of nondestructive evaluation to materials science and technology

    International Nuclear Information System (INIS)

    Baldev Raj; Rajagopalan, C.

    1996-01-01

    The paper reviews the current status of Nondestructive Testing and Evaluation (NDT and E), in relation to materials science and technology. It suggests a path of growth for Nondestructive Testing and Evaluation, taking into account the increase in data and knowledge. We recommend Artificial Intelligence (AI) concepts for maximising the contributions of and benefits from, Nondestructive Testing and Evaluation. (author)

  12. Proceedings: 19th International Nondestructive Testing and Evaluation of Wood Symposium

    Science.gov (United States)

    Robert J. Ross; Raquel Gonçalves; Xiping Wang

    2015-01-01

    The 19th International Nondestructive Testing and Evaluation of Wood Symposium was hosted by the University of Campinas, College of Agricultural Engineering (FEAGRI/UNICAMP), and the Brazilian Association of Nondestructive Testing and Evaluation (ABENDI) in Rio de Janeiro, Brazil, on September 22–25, 2015. This Symposium was a forum for those involved in nondestructive...

  13. Mathematical modelling of ultrasonic non-destructive evaluation

    Directory of Open Access Journals (Sweden)

    Larissa Ju Fradkin

    2001-01-01

    Full Text Available High-frequency asymptotics have been used at our Centre to develop codes for modelling pulse propagation and scattering in the near-field of the ultrasonic transducers used in NDE (Non-Destructive Evaluation, particularly of walls of nuclear reactors. The codes are hundreds of times faster than the direct numerical codes but no less accurate.

  14. Nondestructive testing of austenitic casting and dissimilar metal welds

    International Nuclear Information System (INIS)

    Lahdenperae, K.

    1995-01-01

    The publication is a literature study of nondestructive testing of dissimilar metal welds and cast austenitic components in PWR and BWR plants. A major key to the successful testing is a realistic mockup made of the materials to be tested. The inspectors must also be trained and validated using suitable mockups. (42 refs., 27 figs., 10 tabs.)

  15. Nondestructive evaluation of LWR spent fuel shipping casks

    International Nuclear Information System (INIS)

    Ballard, D.W.

    1978-02-01

    An analysis of nondestructive testing (NDT) methods currently being used to evaluate the integrity of Light Water Reactor (LWR) spent fuel shipping casks is presented. An assessment of anticipated NDT needs related to breeder reactor cask requirements is included. Specific R and D approaches to probable NDT problem areas such as the evaluation of austenitic stainless steel weldments are outlined

  16. Online Preventative Non-Destructive Evaluation in Automated Fibre Placement

    NARCIS (Netherlands)

    Tonnaer, R.; Shroff, S.; Groves, R.M.

    2016-01-01

    The strict quality requirements for aerospace composite struc- tures give rise to costly quality control procedures. In automated bre placement (AFP) these procedures rely heavily on manual work and inspection. This research aims at performing preventative non-destructive evaluation of composite

  17. Non-destructive controls in the steel tube industry

    International Nuclear Information System (INIS)

    Mondot, J.

    1978-01-01

    The main non-destructive control methods in the tube industry are reviewed: eddy currents, particularly well adapted to small tubes; magnetoscopic testing for weldless tubes; ultrasonic waves widely used for thick weldless tubes and weldings; radiography, to examine tube ends and the known questionable zones; measure of diameters by laser [fr

  18. Nondestructive testing methods in building industry '83. Part 1

    International Nuclear Information System (INIS)

    1983-10-01

    The conference heard 52 papers of which 11 were incorporated in INIS. The subject of these was the use of radiometric methods and instruments for nondestructive testing of building materials and ways of testing the quality of concrete during nuclear power plant construction. (J.P.)

  19. Ultrasonic and advanced methods for nondestructive testing and material characterization

    National Research Council Canada - National Science Library

    Chen, C. H

    2007-01-01

    ... and physics among others. There are at least two dozen NDT methods in use. In fact any sensor that can examine the inside of material nondestructively is useful for NDT. However the ultrasonic methods are still most popular because of its capability, flexibility, and relative cost effectiveness. For this reason this book places a heavy emphasis...

  20. Nondestructive evaluation of warm mix asphalt through resonant column testing.

    Science.gov (United States)

    2014-02-01

    Non-destructive testing has been used for decades to characterize engineering properties of hot-mix asphalt. Among such tests is the resonant column (RC) test, which is commonly used to characterize soil materials. The resonant column device at Penn ...

  1. NonDestructive Evaluation for Industrial & Development Applications

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, James F. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-10-12

    Provide overview of weld inspection for Non-Destructive Testing at LANL. This includes radiography (RT/DR/CR/CT for x-ray & neutron sources), ultrasonic testing (UT/PAUT), dye penetrant inspection (PT), eddy current inspection (ET) and magnetic particle testing (MT). Facilities and capabilities for weld inspection will be summarized with examples.

  2. Non-destructive controls in the mechanical industry

    Energy Technology Data Exchange (ETDEWEB)

    Jarlan, L

    1978-12-01

    The sequence of operations implicating the mechanical industries from the suppliers to their customers is briefly recalled; a description of the field of application of non-destructive control methods in these industries is given. Follows a description of some recent typical applications of the principal methods: radiography, ultrasonic waves, magnetism, acoustic emission, sonic control, tracer techniques.

  3. Nondestructive Investigation of Wet Building Material: Multimethodical Approach

    Czech Academy of Sciences Publication Activity Database

    Válek, Jan; Kruschwitz, S.; Wöstmann, J.; Kind, T.; Valach, Jaroslav; Köpp, Ch.; Lesák, Jaroslav

    2010-01-01

    Roč. 24, č. 5 (2010), s. 462-472 ISSN 0887-3828 Grant - others:evropská komise(XE) CHEF- SSPI-044251 Institutional research plan: CEZ:AV0Z20710524 Keywords : nondestructive tests * moisture * masonry Subject RIV: JN - Civil Engineering Impact factor: 0.293, year: 2010

  4. Training manuals for nondestructive testing using magnetic particles

    Science.gov (United States)

    1968-01-01

    Training manuals containing the fundamentals of nondestructive testing using magnetic particle as detection media are used by metal parts inspectors and quality assurance specialists. Magnetic particle testing involves magnetization of the test specimen, application of the magnetic particle and interpretation of the patterns formed.

  5. Laser plasma X-ray for non-destructive inspection

    International Nuclear Information System (INIS)

    Yagi, T.; Kusama, H.

    1995-01-01

    External electric field is applied to the laser produced plasma, and its found that plasma shape in soft X-ray region is changed due to the penetrating electric field. The plasma emits strong hard X-ray, which can be used as a compact light source for non-destructive inspection. (author)

  6. Utilization and reliability of nondestructive testing in ordnance

    International Nuclear Information System (INIS)

    Maranhao, M.; Alves, L.E.G.

    1983-01-01

    Information about nondestructive testing used in ordnance are presented. For propellants and breaking load ultrasonic testing and X-ray are used. For skyrocket propellants the X-ray is used to test the continuity of the explosive mass and the burn inhibiting agent. For rupture explosive, the X-ray is used to test the continuity of explosive mass. (E.G.) [pt

  7. Nondestructive evaluation of incipient decay in hardwood logs

    Science.gov (United States)

    Xiping Wang; Jan Wiedenbeck; Robert J. Ross; John W. Forsman; John R. Erickson; Crystal Pilon; Brian K. Brashaw

    2005-01-01

    Decay can cause significant damage to high-value hardwood timber. New nondestructive evaluation (NDE) technologies are urgently needed to effectively detect incipient decay in hardwood timber at the earliest possible stage. Currently, the primary means of inspecting timber relies on visual assessment criteria. When visual inspections are used exclusively, they provide...

  8. Non-destructive control: technologies, applications and markets

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    A description of NDC - nondestructive controls - (acoustic emission, Eddy currents, infrared and thermal, liquid penetrants, magnetic particles, radiographic, ultrasonic, visual and optical techniques) is given with various industrial applications and market trends. Some research projects, contacts and a list of NDC systems main manufacturers are given. (A.B.). 37 figs. and tabs

  9. Application of liquid crystals in thermal nondestructive evaluation

    International Nuclear Information System (INIS)

    Panakal, J.P.; Mukherjee, S.; Ghosh, J.K.

    1983-01-01

    In recent years, thermal nondestructive evaluation using Cholestric liquid crystals have found wide applications in industry. Thermography using Cholesteric liquid crystals can be used for detection of nonbonds in metallic composites, hot spots in electronic circuits and preliminary examination of welded pressure vessels. This paper presents the results of experiments on thermography of components using encapsulated liquid crystals. (author)

  10. Non-destructive Faraday imaging of dynamically controlled ultracold atoms

    DEFF Research Database (Denmark)

    Gajdacz, Miroslav; Pedersen, Poul Lindholm; Mørch, Troels

    2013-01-01

    We describe an easily implementable method for non-destructive measurements of ultracold atomic clouds based on dark field imaging of spatially resolved Faraday rotation. The signal-to-noise ratio is analyzed theoretically and, in the absence of experimental imperfections, the sensitivity limit...

  11. Stress wave nondestructive evaluation of Douglas-fir peeler cores

    Science.gov (United States)

    Robert J. Ross; John I. Zerbe; Xiping Wang; David W. Green; Roy F. Pellerin

    2005-01-01

    With the need for evaluating the utilization of veneer peeler log cores in higher value products and the increasing importance of utilizing round timbers in poles, posts, stakes, and building construction components, we conducted a cooperative project to verify the suitability of stress wave nondestructive evaluation techniques for assessing peeler cores and some...

  12. Nondestructive evaluation of oriented strand board exposed to decay fungi.

    Science.gov (United States)

    Barbara L. Illman; Vina W. Yang; Robert J. Ross; William J. Nelson

    2002-01-01

    Stress wave nondestructive evaluation (NDE) technologies are being used in our laboratory to evaluate the performance properties of engineered wood. These techniques have proven useful in the inspection of timber structures to locate internal voids and decayed or deteriorated areas in large timbers. But no information exists concerning NDE and important properties of...

  13. Non-destructive testing of electronic component packages

    International Nuclear Information System (INIS)

    Anderle, C.

    1975-01-01

    A non-destructive method of investigating packaged parts of semiconductor components by X radiation is described and the relevant theoretical relations limiting this technique are derived. The application of the technique is demonstrated in testing several components. The described method is iNsimple and quick. (author)

  14. Nondestructive test for assembly relationship of initiating explosive device

    International Nuclear Information System (INIS)

    Wang Xiangang; Zhang Chaozong; Guo Zhiping

    2009-01-01

    A 3D computed tomography (CT) method to inspect assembly relationship of initiating explosive device and to nondestructively evaluate assembly relationship by building geometric model from CT images was described. The experiment result proves that this method accurately inspects assembly relationship of initiating explosive device. (authors)

  15. Non-destructive analysis of the oil composition of soybean seeds by natural abundance carbon-13 nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Yoshida, M.; Kano, H.; Ishida, N.; Yoshida, T.

    1989-01-01

    The signals of fatty acids in the form of triglycerides were observed in the 13 C NMR spectrum of an intact soybean seed. The major fatty acid component composition of triglycerides in a soybean seed, which includes linoleic acid, oleic acid and palmitic acid, was estimated by subtracting the spectra of authentic fatty acids from the spectrum of the intact soybean seeds. The fatty acid compositions of seeds of 11 Japanese soybean cultivars and 5 lines bred at the Asian Vegetable Research and Development Center (AVRDC) were estimated by this rapid (within 1hr for one seed) and nondestructive analytical method. (author)

  16. Training Guidelines in Non-destructive Testing Techniques. 2013 Edition

    International Nuclear Information System (INIS)

    2014-12-01

    The IAEA promotes industrial applications of radiation technology, including non-destructive testing (NDT), through activities such as Technical Cooperation Projects (national and regional) and Coordinated Research Projects. Through this cooperation, Member States have initiated national programmes for the training and certification of NDT personnel. National certifying bodies have also been established based on International Organization for Standardization (ISO) standards. As part of these efforts, the IAEA has been actively involved in developing training materials. Consequently, IAEA-TECDOC-407, Training Guidelines in Non-destructive Testing Techniques, was published in 1987, then revised and expanded as IAEA-TECDOC-628 in 1991. Revisions of IAEA-TECDOC-628 were considered essential to meet the demands of end-user industries in Member States, and revised and expanded versions were issued in 2002 and 2008. These latter versions included work conducted by the International Committee for Non-Destructive Testing (ICNDT) and many national NDT societies. It is one of the publications referred to in ISO 9712:2005, Non-destructive Testing: Qualification and Certification of Personnel, which in turn is an internationally accepted standard, revised as ISO 9712:2012, Non-destructive Testing: Qualification and Certification of NDT Personnel. This publication is an updated version of IAEA-TECDOC-628. The content of which has been revised following the changes of ISO 9712 converging with EN 473 and becoming EN ISO 9712:2012, based on the experience of experts and comments from end-user industries. The details of the topics on each subject have been expanded to include the latest developments in the respective methods. The incorporated changes will assist the end-user industries to update their NDT qualification and certification schemes and course materials. This publication, like the previous versions, will continue to play an important role in international harmonization

  17. Nondestructive verification and assay systems for spent fuels. Technical appendixes

    International Nuclear Information System (INIS)

    Cobb, D.D.; Phillips, J.R.; Baker, M.P.

    1982-04-01

    Six technical appendixes are presented that provide important supporting technical information for the study of the application of nondestructive measurements to spent-fuel storage. Each appendix addresses a particular technical subject in a reasonably self-contained fashion. Appendix A is a comparison of spent-fuel data predicted by reactor operators with measured data from reprocessors. This comparison indicates a rather high level of uncertainty in previous burnup calculations. Appendix B describes a series of nondestructive measurements at the GE-Morris Operation Spent-Fuel Storage Facility. This series of experiments successfully demonstrated a technique for reproducible positioning of fuel assemblies for nondestructive measurement. The experimental results indicate the importance of measuring the axial and angular burnup profiles of irradiated fuel assemblies for quantitative determination of spent-fuel parameters. Appendix C is a reasonably comprehensive bibliography of reports and symposia papers on spent-fuel nondestructive measurements to April 1981. Appendix D is a compendium of spent-fuel calculations that includes isotope production and depletion calculations using the EPRI-CINDER code, calculations of neutron and gamma-ray source terms, and correlations of these sources with burnup and plutonium content. Appendix E describes the pulsed-neutron technique and its potential application to spent-fuel measurements. Although not yet developed, the technique holds the promise of providing separate measurements of the uranium and plutonium fissile isotopes. Appendix F describes the experimental program and facilities at Los Alamos for the development of spent-fuel nondestructive measurement systems. Measurements are reported showing that the active neutron method is sensitive to the replacement of a single fuel rod with a dummy rod in an unirradiated uranium fuel assembly

  18. Eddy Current Nondestructive Residual Stress Assessment in Shot-Peened Nickel-Base Superalloys

    International Nuclear Information System (INIS)

    Blodgett, M.P.; Yu, F.; Nagy, P.B.

    2005-01-01

    Shot peening and other mechanical surface enhancement methods improve the fatigue resistance and foreign-object damage tolerance of metallic components by introducing beneficial near-surface compressive residual stresses and hardening the surface. However, the fatigue life improvement gained via surface enhancement is not explicitly accounted for in current engine component life prediction models because of the lack of accurate and reliable nondestructive methods that could verify the presence of compressive near-surface residual stresses in shot-peened hardware. In light of its frequency-dependent penetration depth, the measurement of eddy current conductivity has been suggested as a possible means to allow the nondestructive evaluation of subsurface residual stresses in surface-treated components. This technique is based on the so-called piezoresistivity effect, i.e., the stress-dependence of electrical resistivity. We found that, in contrast with most other materials, surface-treated nickel-base superalloys exhibit an apparent increase in electrical conductivity at increasing inspection frequencies, i.e., at decreasing penetration depths. Experimental results are presented to illustrate that the excess frequency-dependent apparent eddy current conductivity of shot-peened nickel-base superalloys can be used to estimate the absolute level and penetration depth of the compressive residual stress layer both before and after partial thermal relaxation

  19. Non-destructive forensic latent fingerprint acquisition with chromatic white light sensors

    Science.gov (United States)

    Leich, Marcus; Kiltz, Stefan; Dittmann, Jana; Vielhauer, Claus

    2011-02-01

    Non-destructive latent fingerprint acquisition is an emerging field of research, which, unlike traditional methods, makes latent fingerprints available for additional verification or further analysis like tests for substance abuse or age estimation. In this paper a series of tests is performed to investigate the overall suitability of a high resolution off-the-shelf chromatic white light sensor for the contact-less and non-destructive latent fingerprint acquisition. Our paper focuses on scanning previously determined regions with exemplary acquisition parameter settings. 3D height field and reflection data of five different latent fingerprints on six different types of surfaces (HDD platter, brushed metal, painted car body (metallic and non-metallic finish), blued metal, veneered plywood) are experimentally studied. Pre-processing is performed by removing low-frequency gradients. The quality of the results is assessed subjectively; no automated feature extraction is performed. Additionally, the degradation of the fingerprint during the acquisition period is observed. While the quality of the acquired data is highly dependent on surface structure, the sensor is capable of detecting the fingerprint on all sample surfaces. On blued metal the residual material is detected; however, the ridge line structure dissolves within minutes after fingerprint placement.

  20. Non-destructive evaluation of UV pulse laser-induced damage performance of fused silica optics.

    Science.gov (United States)

    Huang, Jin; Wang, Fengrui; Liu, Hongjie; Geng, Feng; Jiang, Xiaodong; Sun, Laixi; Ye, Xin; Li, Qingzhi; Wu, Weidong; Zheng, Wanguo; Sun, Dunlu

    2017-11-24

    The surface laser damage performance of fused silica optics is related to the distribution of surface defects. In this study, we used chemical etching assisted by ultrasound and magnetorheological finishing to modify defect distribution in a fused silica surface, resulting in fused silica samples with different laser damage performance. Non-destructive test methods such as UV laser-induced fluorescence imaging and photo-thermal deflection were used to characterize the surface defects that contribute to the absorption of UV laser radiation. Our results indicate that the two methods can quantitatively distinguish differences in the distribution of absorptive defects in fused silica samples subjected to different post-processing steps. The percentage of fluorescence defects and the weak absorption coefficient were strongly related to the damage threshold and damage density of fused silica optics, as confirmed by the correlation curves built from statistical analysis of experimental data. The results show that non-destructive evaluation methods such as laser-induced fluorescence and photo-thermal absorption can be effectively applied to estimate the damage performance of fused silica optics at 351 nm pulse laser radiation. This indirect evaluation method is effective for laser damage performance assessment of fused silica optics prior to utilization.

  1. Nondestructive ultrasonic characterization of armor grade silicon carbide

    Science.gov (United States)

    Portune, Andrew Richard

    Ceramic materials have traditionally been chosen for armor applications for their superior mechanical properties and low densities. At high strain rates seen during ballistic events, the behavior of these materials relies upon the total volumetric flaw concentration more so than any single anomalous flaw. In this context flaws can be defined as any microstructural feature which detriments the performance of the material, potentially including secondary phases, pores, or unreacted sintering additives. Predicting the performance of armor grade ceramic materials depends on knowledge of the absolute and relative concentration and size distribution of bulk heterogeneities. Ultrasound was chosen as a nondestructive technique for characterizing the microstructure of dense silicon carbide ceramics. Acoustic waves interact elastically with grains and inclusions in large sample volumes, and were well suited to determine concentration and size distribution variations for solid inclusions. Methodology was developed for rapid acquisition and analysis of attenuation coefficient spectra. Measurements were conducted at individual points and over large sample areas using a novel technique entitled scanning acoustic spectroscopy. Loss spectra were split into absorption and scattering dominant frequency regimes to simplify analysis. The primary absorption mechanism in polycrystalline silicon carbide was identified as thermoelastic in nature. Correlations between microstructural conditions and parameters within the absorption equation were established through study of commercial and custom engineered SiC materials. Nonlinear least squares regression analysis was used to estimate the size distributions of boron carbide and carbon inclusions within commercial SiC materials. This technique was shown to additionally be capable of approximating grain size distributions in engineered SiC materials which did not contain solid inclusions. Comparisons to results from electron microscopy

  2. Analysis of Radiation Accident of Non-destructive Inspection and Rational Preparing Bills

    International Nuclear Information System (INIS)

    Bae, Junwoo; Yoo, Donghan; Kim, Hee Reyoung

    2013-01-01

    After 2006, according to enactment of Non-destructive Inspection Promotion Act, the number of non-destructive inspection companies and corresponding accident is increased sharply. In this research, it includes characteristic analysis of field of the non-destructive inspection. And from the result of analysis, the purpose of this research is discovering reason for 'Why there is higher accident ratio in non-destructive inspection field, relatively' and preparing effective bill for reducing radiation accidents. The number of worker for non-destructive inspect is increased steadily and non-destructive inspect worker take highest dose. Corresponding to these, it must be needed to prepare bills to protect non-destructive inspect workers. By analysis of accident case, there are many case of carelessness that tools are too heavy to carry it everywhere workers go. And there are some cases caused by deficiency of education that less understanding of radiation and poor operation by less understanding of structure of tools. Also, there is no data specialized to non-destructive inspect field. So, it has to take information from statistical data. Because of this, it is hard to analyze nondestructive inspect field accurately. So, it is required to; preparing rational bills to protect non-destructive inspect workers nondestructive inspect instrument lightening and easy manual which can understandable for low education background people accurate survey data from real worker. To accomplish these, we needs to do; analyze and comprehend the present law about non-destructive inspect worker understand non-destructive inspect instruments accurately and conduct research for developing material developing rational survey to measuring real condition for non-destructive inspect workers

  3. Unbiased estimation of the eyeball volume using the Cavalieri principle on computed tomography images.

    Science.gov (United States)

    Acer, Niyazi; Sahin, Bunyamin; Ucar, Tolga; Usanmaz, Mustafa

    2009-01-01

    The size of the eyeball has been the subject of a few studies. None of them used stereological methods to estimate the volume. In the current study, we estimated the volume of eyeball in normal men and women using the stereological methods. Eyeball volume (EV) was estimated using the Cavalieri principle as a combination of point-counting and planimetry techniques. We used computed tomography scans taken from 36 participants (15 men and 21 women) to estimate the EV. The mean (SD) EV values obtained by planimetry method were 7.49 (0.79) and 7.06 (0.85) cm in men and women, respectively. By using point-counting method, the mean (SD) values were 7.48 (0.85) and 7.21 (0.84) cm in men and women, respectively. There was no statistically significant difference between the findings from the 2 methods (P > 0.05). A weak correlation was found between the axial length of eyeball and the EV estimated by point counting and planimetry (P eyeball.

  4. HAAR TRANSFORM BASED ESTIMATION OF CHLOROPHYLL AND STRUCTURE OF THE LEAF

    OpenAIRE

    Abhinav Arora; R. Menaka; Shivangi Gupta; Archit Mishra

    2013-01-01

    In this paper, the health of a plant is estimated using various non-destructive Image Processing Techniques. Chlorophyll content was detected based on colour Image Processing. The Haar transform is applied to get size of leaf and the parameters.

  5. Geometrical Feature Extraction from Ultrasonic Time Frequency Responses: An Application to Nondestructive Testing of Materials

    Directory of Open Access Journals (Sweden)

    Naranjo Valery

    2010-01-01

    Full Text Available Signal processing is an essential tool in nondestructive material characterization. Pulse-echo inspection with ultrasonic energy provides signals (A-scans that can be processed in order to obtain parameters which are related to physical properties of inspected materials. Conventional techniques are based on the use of a short-term frequency analysis of the A-scan, obtaining a time-frequency response (TFR, to isolate the evolution of the different frequency-dependent parameters. The application of geometrical estimators to TFRs provides an innovative way to complement conventional techniques based on the one-dimensional evolution of an A-scan extracted parameter (central or centroid frequency, bandwidth, etc.. This technique also provides an alternative method of obtaining similar meaning and less variance estimators. A comparative study of conventional versus new proposed techniques is presented in this paper. The comparative study shows that working with binarized TFRs and the use of shape descriptors provide estimates with lower bias and variance than conventional techniques. Real scattering materials, with different scatterer sizes, have been measured in order to demonstrate the usefulness of the proposed estimators to distinguish among scattering soft tissues. Superior results, using the proposed estimators in real measures, were obtained when classifying according to mean scatterer size.

  6. Non-destructive microstructural analysis with depth resolution

    Energy Technology Data Exchange (ETDEWEB)

    Zolotoyabko, E. E-mail: zloto@tx.technion.ac.il; Quintana, J.P

    2003-01-01

    A depth-sensitive X-ray diffraction technique has been developed with the aim of studying microstructural modifications in inhomogeneous polycrystalline materials. In that method, diffraction profiles are measured at different X-ray energies varied by small steps. X-rays at higher energies probe deeper layers of material. Depth-resolved structural information is retrieved by comparing energy-dependent diffraction profiles. The method provides non-destructive depth profiling of the preferred orientation, grain size, microstrain fluctuations and residual strains. This technique is applied to the characterization of seashells. Similarly, energy-variable X-ray diffraction can be used for the non-destructive characterization of different laminated structures and composite materials.

  7. Automation of testing the metrological reliability of nondestructive control systems

    International Nuclear Information System (INIS)

    Zhukov, Yu.A.; Isakov, V.B.; Karlov, Yu.K.; Kovalevskij, Yu.A.

    1987-01-01

    Opportunities of microcomputers are used to solve the problem of testing control-measuring systems. Besides the main program the program of data processing when characterizing the nondestructive control systems is written in the microcomputer. The program includes two modules. The first module contains tests-programs, by which accuracy of functional elements of the microcomputer and interface elements with issuing a message to the operator on readiness of the elements for operation and failure of a certain element are determined. The second module includes: calculational programs when determining metrological reliability of measuring channel reliability, a calculational subprogram for random statistical measuring error, time instability and ''dead time''. Automation of testing metrological reliability of the nondestructive control systems increases reliability of determining metrological parameters and reduces time of system testing

  8. Nondestructive techniques for the control of conditioned radioactive wastes

    International Nuclear Information System (INIS)

    Delprato, U.

    1987-01-01

    The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, γ-scanning, γ-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also discussed

  9. Nondestructive Damage Evaluation in Ceramic Matrix Composites for Aerospace Applications

    Directory of Open Access Journals (Sweden)

    Konstantinos G. Dassios

    2013-01-01

    Full Text Available Infrared thermography (IRT and acoustic emission (AE are the two major nondestructive methodologies for evaluating damage in ceramic matrix composites (CMCs for aerospace applications. The two techniques are applied herein to assess and monitor damage formation and evolution in a SiC-fiber reinforced CMC loaded under cyclic and fatigue loading. The paper explains how IRT and AE can be used for the assessment of the material’s performance under fatigue. IRT and AE parameters are specifically used for the characterization of the complex damage mechanisms that occur during CMC fracture, and they enable the identification of the micromechanical processes that control material failure, mainly crack formation and propagation. Additionally, these nondestructive parameters help in early prediction of the residual life of the material and in establishing the fatigue limit of materials rapidly and accurately.

  10. Nondestructive methods for quality evaluation of livestock products.

    Science.gov (United States)

    Narsaiah, K; Jha, Shyam N

    2012-06-01

    The muscles derived from livestock are highly perishable. Rapid and nondestructive methods are essential for quality assurance of such products. Potential nondestructive methods, which can supplement or replace many of traditional time consuming destructive methods, include colour and computer image analysis, NIR spectroscopy, NMRI, electronic nose, ultrasound, X-ray imaging and biosensors. These methods are briefly described and the research work involving them for products derived from livestock is reviewed. These methods will be helpful in rapid screening of large number of samples, monitoring distribution networks, quick product recall and enhance traceability in the value chain of livestock products. With new developments in the areas of basic science related to these methods, colour, image processing, NIR spectroscopy, biosensors and ultrasonic analysis are expected to be widespread and cost effective for large scale meat quality evaluation in near future.

  11. Non-Destructive Techniques Based on Eddy Current Testing

    Science.gov (United States)

    García-Martín, Javier; Gómez-Gil, Jaime; Vázquez-Sánchez, Ernesto

    2011-01-01

    Non-destructive techniques are used widely in the metal industry in order to control the quality of materials. Eddy current testing is one of the most extensively used non-destructive techniques for inspecting electrically conductive materials at very high speeds that does not require any contact between the test piece and the sensor. This paper includes an overview of the fundamentals and main variables of eddy current testing. It also describes the state-of-the-art sensors and modern techniques such as multi-frequency and pulsed systems. Recent advances in complex models towards solving crack-sensor interaction, developments in instrumentation due to advances in electronic devices, and the evolution of data processing suggest that eddy current testing systems will be increasingly used in the future. PMID:22163754

  12. Non-destructive elecrochemical monitoring of reinforcement corrosion

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn

    been widely accepted as a non-destructive ”state of the art” technique for detection of corrosion in concrete structures. And, over the last decade, the trend in corrosion monitoring has moved towards quantitative non-destructive monitoring of the corrosion rate of the steel reinforcement. A few...... corrosion rate measurement instruments have been developed and are commercially available. The main features of these instruments are the combined use of an electrochemical technique for determining the corrosion rate and a so-called ”confinement technique”, which in principle controls the polarised surface...... area of the reinforcement, i.e. the measurement area. Both on-site investigations and laboratory studies have shown that varying corrosion rates are obtained when the various commercially available instruments are used. And in the published studies, conflicting explanations are given illustrating...

  13. Non-destructive examination system of vitreous body

    Science.gov (United States)

    Shibata, Takuma; Gong, Jin; Watanabe, Yosuke; Kabir, M. Hasnat; Masato, Makino; Furukawa, Hidemitsu; Nishitsuka, Koichi

    2014-04-01

    Eyeball plays a quite important role in acquiring the vision. Vitreous body occupies the largest part of the eyeball and consists of biological, elastic, transparent, gel materials. In the present medical examination, the non-destructive examination method of the vitreous body has not been well established. Here, we focus on an application of dynamic light scattering to this topic. We tried to apply our lab-made apparatus, scanning microscopic light scattering (SMILS), which was specially designed for observing the nanometer-scale network structure in gel materials. In order to examine the vitreous body using SMILS method, a commercial apparatus, nano Partica (Horiba Co. Ltd.) was also customized. We analyzed vitreous body using both the SMILS and the customized nano Partica. We successfully examined the vitreous bodies of healthy pigs in non-destructive way.

  14. Advanced uses of radiation in non-destructive evaluation

    International Nuclear Information System (INIS)

    Baldev Raj; Viswanathan, B.; Venkataraman, B.

    1998-01-01

    The increasing demand for newer materials and stringency of specifications, have expanded the scope of advanced uses of radiation in non-destructive evaluation of materials and industrial components. This paper highlights the application of some of the advanced techniques of radiography and residual stress measurements, using x-ray diffraction, for materials characterisation and testing, based on the results obtained at the author's laboratory. The application of positron annihilation techniques based on the use of radioisotopes and high resolution gamma ray spectroscopy, is introduced as non-destructive tools for materials characterisation. Selective examples of significant results obtained using this technique, on the radiation damage and early stages of fatigue damage in technologically important steels are reviewed from recent works at the author's laboratory and elsewhere. The scope of application of charge particle based thin layer activation method is briefly outlined. (author)

  15. Proceedings of the 5. Pan Pacific conference on nondestructive testing

    International Nuclear Information System (INIS)

    Kittmer, C.A.

    1987-03-01

    This is the fifth in the series of Pan Pacific Conference on Nondestructive Testing held once every two years. The honour of hosting the conference is shared among those countries bordering on the Pacific Ocean, this year the responsibility being granted to Canada. The call for papers for this three day conference attracted significant interest. This provided the Technical Program Committee with an extremely difficult task in reducing the overwhelming response to only 46 (plus 10 alternates) for presentation at the conference, and inclusion in these proceedings. The selected papers provide an international perspective on advances in nondestructive techniques such as ultrasonics, eddy current, radiography, magnetic particle and liquid penetrant, as well as their diverse applications in the various countries involved

  16. New technologies in electromagnetic non-destructive testing

    CERN Document Server

    Huang, Songling

    2016-01-01

    This book introduces novel developments in the field of electromagnetic non-destructive testing and evaluation (NDT/E). The topics include electromagnetic ultrasonic guided wave testing, pulsed eddy current testing, remote field eddy current testing, low frequency eddy current testing, metal magnetic memory testing, and magnetic flux leakage testing. Considering the increasing concern about the safety maintenance of critical structures in various industries and everyday life, these topics presented here will be of particular interest to the readers in the NDT/E field. This book covers both theoretical researches and the engineering applications of the electromagnetic NDT technology. It could serve as a valuable reference for college students and relevant NDT technicians. It is also a useful material for qualification training and higher learning for nondestructive testing professionals.

  17. Nondestructive testing for manufacture and maintenance work. Abstracts

    International Nuclear Information System (INIS)

    1985-01-01

    The opening lecture of the meeting put special emphasis on the economic impact of nuclear energy utilization, whereas the principal lecture discussed the role of nondestructive testing methods in manufacture and maintenance work. A motion picture shown to the audience explained thermoshock experiments in a superheated steam reactor. All in all 32 papers were presented, dealing with nondestructive testing methods using ultrasounds, X-rays, eddy currents, ultrasound imaging, broad-band holography, radiator assemblies, magnet powders, pulse and eddy current signals, and computed tomography. Aircraft testing - in particular welds testing - was a main topic. The papers were supplemented by poster sessions including 60 posters on ultrasound testing, electric and magnetic testing methods, and radiographic testing. (HP) [de

  18. Research on nondestructive examination methods for CANDU fuel channel inspection

    International Nuclear Information System (INIS)

    Soare, M.; Petriu, F.; Toma, V.; Revenco, V.; Calinescu, A.; Ciocan, R.; Iordache, C.; Popescu, L.; Mihalache, M.; Murgescu, C.

    1995-01-01

    The requirements of the 1994 edition of CAN/CSA-N285.4 Periodic Inspection Standard, which address all known and postulated degradation mechanisms and introduce material surveillance demands, involve a growing need for improved nondestructive examination (NDE) methods and technologies. In order to have a proper technical support in its decisions concerning fuel channel inspections at Cernavoda NPP, the Romanian Power Authority (RENEL) initiated a Research Program regarding the nondestructive characterization of the fuel channels structural integrity. The paper presents the most significant results obtained on this Research Program: the ENDUS experimental system for Laboratory simulation of the fuel channel inspection, ultrasonic Rayleigh-Lamb waves technique for pressure tubes examination, phase analysis technique for near-surface flaws, influence of the metallurgical state of the pressure tube material on the eddy current defectoscopic signals, characterization of plastic deformation and fracture of zirconium alloys by acoustic emission. (author)

  19. The non-destructive control, a major constituent of quality

    International Nuclear Information System (INIS)

    Anon.

    1998-01-01

    The number of continuous research and development works about non-destructive control in all sectors of activity is justified by the increasing need for high quality materials without anomalies. This paper gives a overview of the state of the art and of the recent trends in non-destructive testing researches in different sectors: aeronautics, nuclear industry, automotive industry. New studies and techniques are presented: ultrasonic testing of welds on large diameter pipes, automated applications of ultrasonic testing, ultrasound/computer-aided design coupling, pressure vessels inspection using acoustic emission testing (leaks detection, application to composite materials), numerical radiography (image visualisation and processing), magnetic testing (steel damage detection using Barkhausen noise testing), 'shearography' (detection of the loss of thickness in pipes due to corrosion), X-ray tomography (density measurement of sintered steels, fluid flow calculations in automobile parts). (J.S.)

  20. A non-destructive DNA sampling technique for herbarium specimens.

    Science.gov (United States)

    Shepherd, Lara D

    2017-01-01

    Herbarium specimens are an important source of DNA for plant research but current sampling methods require the removal of material for DNA extraction. This is undesirable for irreplaceable specimens such as rare species or type material. Here I present the first non-destructive sampling method for extracting DNA from herbarium specimens. DNA was successfully retrieved from robust leaves and/or stems of herbarium specimens up to 73 years old.

  1. Nondestructive evaluation of metallic structures using a SQUID magnetometer

    International Nuclear Information System (INIS)

    Weinstock, H.; Nisenoff, M.

    1985-01-01

    We present one of the first reports of the use of SQUID instrumentation for nondestructive evaluation of electrically conducting and ferromagnetic specimens. We report preliminary experiments on the use of SQUIDs for the detection of defects (such as cracks, holes, weld seams, variations in wall thickness, effects of corrosion, etc.) in the walls of a hollow pipe, and for monitoring the magnetic state of a ferromagnetic sample under stress-strain loading conditions. (orig./BUD)

  2. Method for nondestructive fuel assay of laser fusion targets

    Science.gov (United States)

    Farnum, Eugene H.; Fries, R. Jay

    1976-01-01

    A method for nondestructively determining the deuterium and tritium content of laser fusion targets by counting the x rays produced by the interaction of tritium beta particles with the walls of the microballoons used to contain the deuterium and tritium gas mixture under high pressure. The x rays provide a direct measure of the tritium content and a means for calculating the deuterium content using the initial known D-T ratio and the known deuterium and tritium diffusion rates.

  3. Federal laboratory nondestructive testing research and development applicable to industry

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.A.; Moore, N.L.

    1987-02-01

    This document presents the results of a survey of nondestructive testing (NDT) and related sensor technology research and development (R and D) at selected federal laboratories. Objective was to identify and characterize NDT activities that could be applied to improving energy efficiency and overall productivity in US manufacturing. Numerous federally supported R and D programs were identified in areas such as acoustic emissions, eddy current, radiography, computer tomography and ultrasonics. A Preliminary Findings Report was sent to industry representatives, which generated considerable interest.

  4. Non-destructive analysis of archaeological bronzes by nuclear techniques

    International Nuclear Information System (INIS)

    Respaldiza, M.A.; Gomez-Tubio, B.M.; Sanchez del Junco, A.; Barranco, F.; Saiz-Jimenez, C.

    1994-01-01

    This paper studies a method for overcoming the difficulty of corroded surfaces by means of nondestructive nuclear methods in the determination of the composition of archaeological bronzes. It consists of the combination of PIXE or XRF information with Gamma Ray Transmission (GRT) data. A wide range applicability of this combined method is established by comparison with profiles of concentrations along the bronzes' patina obtained by SEM-EDAX. (orig.)

  5. The inverse problem of the magnetostatic nondestructive testing

    International Nuclear Information System (INIS)

    Pechenkov, A.N.; Shcherbinin, V.E.

    2006-01-01

    The inverse problem of magnetostatic nondestructive testing consists in the calculation of the shape and magnetic characteristics of a flaw in a uniform magnetized body with measurement of static magnetic field beyond the body. If the flaw does not contain any magnetic material, the inverse problem is reduced to identification of the shape and magnetic susceptibility of the substance. This case has been considered in the study [ru

  6. Method for nondestructive fuel assay of laser fusion targets

    International Nuclear Information System (INIS)

    Farnum, E.H.; Fries, R.J.

    1976-01-01

    A method is described for nondestructively determining the deuterium and tritium content of laser fusion targets by counting the x rays produced by the interaction of tritium beta particles with the walls of the microballoons used to contain the deuterium and tritium gas mixture under high pressure. The x rays provide a direct measure of the tritium content and a means for calculating the deuterium content using the initial known D-T ratio and the known deuterium and tritium diffusion rates

  7. Nondestructive Evaluation of Ceramic Candle Filters Using Vibration Response

    International Nuclear Information System (INIS)

    Chen, Roger H.L.; Kiriakidis, Alejandro C.; Peng, Steve W.

    1997-01-01

    This study aims at the development of an effective nondestructive evaluation technique to predict the remaining useful life of a ceramic candle filter during a power plant's annual maintenance shutdown. The objective of the present on-going study is to establish the vibration signatures of ceramic candle filters at varying degradation levels due to different operating hours, and to study the various factors involving the establishment of the signatures

  8. Guidebook on non-destructive testing of concrete structures

    International Nuclear Information System (INIS)

    2002-01-01

    The International Atomic Energy Agency has been active in the promotion of non-destructive testing (NDT) technology for many years. NDT is an important component of a number of IAEA regional projects. This guidebook deals with NDT of concrete. This book covers a wide range of NDT methods including industrial radiography, ultrasonic testing, electromagnetic testing, infrared thermography, etc. Codes, standards, specifications and procedures are also covered

  9. Inspection of diesel engine injectors by several electromagnetic nondestructive methods

    Czech Academy of Sciences Publication Activity Database

    Vértesy, G.; Balassa, P.; Gasparics, A.; Tomáš, Ivan; Mészáros, I.

    2017-01-01

    Roč. 54, č. 3 (2017), s. 449-459 ISSN 1383-5416 R&D Projects: GA ČR GB14-36566G Institutional support: RVO:68378271 Keywords : electromagnetic nondestructive testing * diesel engine injector * eddy current testing * magnetic hysteresis measurements * magnetic adaptive testing Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 0.769, year: 2016

  10. Nondestructive assay instrument for measurement of plutonium in solutions

    International Nuclear Information System (INIS)

    Shirk, D.G.; Hsue, F.; Li, T.K.; Canada, T.R.

    1979-01-01

    A nondestructive assay (NDA) instrument that measures the 239 Pu content in solutions, using a passive gamma-ray spectroscopy technique, has been developed and installed in the LASL Plutonium Processing Facility. A detailed evaluation of this instrument has been performed. The results show that the instrument can routinely determine 239 Pu concentrations of 1 to 500 g/l with accuracies of 1 to 5% and assay times of 1 to 2 x 10 3 s

  11. INTERFACE DEVICE FOR NONDESTRUCTIVE TESTING OF RESIDUAL SURFACE STRESSES

    Directory of Open Access Journals (Sweden)

    Gennady A. Perepelkin

    2016-01-01

    Full Text Available The paper considers the organization of connection of a personal computer with a device for nondestructive testing of residual surface stresses. The device works is based on the phenomenon of diffraction of ionizing radiation from the crystal lattice near the surface of the crystallites. Proposed software interface to the organization for each type of user: the device developers, administrators, users. Some aspects of the organization of communication microcontroller to a PC via USB-port

  12. Non-Destructive Testing for Control of Radioactive Waste Package

    Science.gov (United States)

    Plumeri, S.; Carrel, F.

    2015-10-01

    Characterization and control of radioactive waste packages are important issues in the management of a radioactive waste repository. Therefore, Andra performs quality control inspection on radwaste package before disposal to ensure the compliance of the radwast characteristics with Andra waste disposal specifications and to check the consistency between Andra measurements results and producer declared properties. Objectives of this quality control are: assessment and improvement of producer radwaste packages quality mastery, guarantee of the radwaste disposal safety, maintain of the public confidence. To control radiological characteristics of radwaste package, non-destructive passive methods (gamma spectrometry and neutrons counting) are commonly used. These passive methods may not be sufficient, for instance to control the mass of fissile material contained inside radwaste package. This is particularly true for large concrete hull of heterogeneous radwaste containing several actinides mixed with fission products like 137Cs. Non-destructive active methods, like measurement of photofission delayed neutrons, allow to quantify the global mass of actinides and is a promising method to quantify mass of fissile material. Andra has performed different non-destructive measurements on concrete intermediate-level short lived nuclear waste (ILW-SL) package to control its nuclear material content. These tests have allowed Andra to have a first evaluation of the performance of photofission delayed neutron measurement and to identify development needed to have a reliable method, especially for fissile material mass control in intermediate-level long lived waste package.

  13. Kalman filter analysis of delayed neutron nondestructive assay measurements

    International Nuclear Information System (INIS)

    Aumeier, S. E.

    1998-01-01

    The ability to nondestructively determine the presence and quantity of fissile and fertile nuclei in various matrices is important in several nuclear applications including international and domestics safeguards, radioactive waste characterization and nuclear facility operations. Material irradiation followed by delayed neutron counting is a well known and useful nondestructive assay technique used to determine the fissile-effective content of assay samples. Previous studies have demonstrated the feasibility of using Kalman filters to unfold individual isotopic contributions to delayed neutron measurements resulting from the assay of mixes of uranium and plutonium isotopes. However, the studies in question used simulated measurement data and idealized parameters. We present the results of the Kalman filter analysis of several measurements of U/Pu mixes taken using Argonne National Laboratory's delayed neutron nondestructive assay device. The results demonstrate the use of Kalman filters as a signal processing tool to determine the fissile and fertile isotopic content of an assay sample from the aggregate delayed neutron response following neutron irradiation

  14. Assuring the reliability of structural components - experimental data and non-destructive examination requirements

    International Nuclear Information System (INIS)

    Lucia, A.C.

    1984-01-01

    The probability of failure of a structural component can be estimated by either statistical methods or a probabilistic structural reliability approach (where the failure is seen as a level crossing of a damage stochastic process which develops in space and in time). The probabilistic approach has the advantage that it makes available not only an absolute value of the failure probability but also a lot of additional information. The disadvantage of the probabilistic approach is its complexity. It is discussed for the following situations: reliability of a structural component, material properties, data for fatigue crack growth evaluation, a bench mark exercise on reactor pressure vessel failure probability computation, and non-destructive examination for assuring a given level of structural reliability. (U.K.)

  15. Commissioning of calorimeter in radiochemical laboratory for non-destructive assay of special nuclear materials

    International Nuclear Information System (INIS)

    Patra, S.; Mhatre, A.M.; Agarwal, C.; Chaudhury, S.; Pujari, P.K.

    2017-01-01

    Accounting of special nuclear materials (SNM) in every stages of nuclear fuel cycle is a necessity where one needs the quantitative estimation of SNM in variety of samples like sealed containers or finished products without altering its physical and chemical form. Non-destructive assay (NDA) techniques are capable of assaying such samples by the way of measuring passive/active neutrons/gamma rays or by the measurement of decay heat. Radiochemistry Division has been actively involved in the development and deployment of various NDA methodologies for meeting the demand of nuclear material accounting as and when required. Recently a radiometric calorimeter, developed by Reactor Control Division, E and I Group, BARC, has been installed in Lab C-33, Radiochemistry Division

  16. EQUIPMENT FOR NONDESTRUCTIVE TESTING OF SILICON WAFERS SUBMICRON TOPOLOGY DURING THE FABRICATION OF INTEGRATED CIRCUITS

    Directory of Open Access Journals (Sweden)

    S. A. Chizhik

    2013-01-01

    Full Text Available The advantages of using an atomic force microscopy in manufacturing of submicron integrated circuits are described. The possibilities of characterizing the surface morphology and the etching profile for silicon substrate and bus lines, estimation of the periodicity and size of bus lines, geometrical stability for elementary bus line are shown. Methods of optical and atomic force microcopies are combined in one diagnostic unit. Scanning  probe  microscope  (SPM  200  is  designed  and  produced.  Complex  SPM  200  realizes  nondestructive control of microelectronics elements made on silicon wafers up to 200 mm in diameter and it is introduced by JSC «Integral» for the purpose of operational control, metrology and acceptance of the final product.

  17. Non-destructive local determination of doping additions and main components in single crystals

    International Nuclear Information System (INIS)

    Ehksperiandova, L.P.; Blank, A.B.; Kukhtina, N.N.; Afanasiadi, L.I.

    1994-01-01

    Procedures for local non-destructive determination of elements in optical and scintillation single crystals are developed. They are applied for determination of the main components (in cadmium tungstate) and doping additions (tellurium in zinc selenide, europium in gadolinium silicate). The metrological characteristics of the developed micro-analysis methods are estimated. Segregation of the main components and doping additions in the objects under consideration are investigated. Tellurium is found to be distributed uniformly on the cross-sections of bulk zinc selenide single crystals. The segregation of europium along gadolinium silicate ingots is almost absent. On the cross-section surface of cadmium tungstate single crystals the microregions are found characterized by the prevailing contents of cadmium or tungsten

  18. Annual meeting 1996 'Nondestructive materials testing'. German, Austrian and Swiss nondestructive materials testing standards as mirrored by international standardization. Vol. 1. Lectures

    International Nuclear Information System (INIS)

    1996-01-01

    The volume contains 45 lectures which were given at the annual meeting of the German Society for Nondestructive Testing on May 13-15, 1996 at Lindau. The main subjects were: Standardization of nondestructive testing, irradiation testing, ultrasonic testing and electromagnetic processes. 13 individual articles were included in the ENERGY database. (MM) [de

  19. Annual meeting 1996 'Nondestructive material testing'. German, Austrian and Swiss nondestructive materials testing standards as mirrored by international standardization. Vol. 2. Posters

    International Nuclear Information System (INIS)

    1996-01-01

    The volume contains 49 poster articles which were presented at the Annual Meeting of the German Society for Nondestructive Testing at Lindau on May 13-15, 1996. The main subjects were: Standardization of nondestructive testing, irradiation testing, ultrasonic testing and electromagnetic processes. 16 individual articles were included in the ENERGY databank. (MM) [de

  20. A new fractionator principle with varying sampling fractions: exemplified by estimation of synapse number using electron microscopy

    DEFF Research Database (Denmark)

    Witgen, Brent Marvin; Grady, M. Sean; Nyengaard, Jens Randel

    2006-01-01

    The quantification of ultrastructure has been permanently improved by the application of new stereological principles. Both precision and efficiency have been enhanced. Here we report for the first time a fractionator method that can be applied at the electron microscopy level. This new design...... the total object number using section sampling fractions based on the average thickness of sections of variable thicknesses. As an alternative, this approach estimates the correct particle section sampling probability based on an estimator of the Horvitz-Thompson type, resulting in a theoretically more...

  1. Nanorobotic Manipulation Setup for Pick-and-Place Handling and non-destructive Characterization of Carbon Nanotubes

    DEFF Research Database (Denmark)

    Eicchorn, V.; Carlson, Kenneth; Andersen, Karin Nordström

    2007-01-01

    . The pick-and-place task is carried out by using an electrothermal actuated microgripper, designed for controlled manipulation of nanotubes. The nanotube is picked up from an array of multiwalled carbon nanotubes (MWCNTs) and transferred to the tip of an atomic force microscope (AFM) probe in order...... to assemble a high-aspect ratio AFM supertip. Another application of the nanorobotic setup considered in this paper is the nondestructive mechanical characterization of CNTs. A piezoresistive AFM probe is used to bend MWCNTs, while the bending force is measured, in order to estimate the Young's modulus...

  2. Uranium and thorium loadings determined by chemical and nondestructive methods in HTGR fuel rods for the Fort St. Vrain Early Validation Irradiation Experiment

    International Nuclear Information System (INIS)

    Angelini, P.; Rushton, J.E.

    1979-01-01

    The Fort St. Vrain Early Validation Irradiation Experiment is an irradiation test of reference and of improved High-Temperature Gas-Cooled Reactor fuels in the Fort St. Vrain Reactor. The irradiation test includes fuel rods fabricated at ORNL on an engineering scale fuel rod molding machine. Fuel rods were nondestructively assayed for 235 U content by a technique based on the detection of prompt-fission neutrons induced by thermal-neutron interrogation and were later chemically assayed by using the modified Davies Gray potentiometric titration method. The chemical analysis of the thorium content was determined by a volumetric titration method. The chemical assay method for uranium was evaluated and the results from the as-molded fuel rods agree with those from: (1) large samples of Triso-coated fissile particles, (2) physical mixtures of the three particle types, and (3) standard solutions to within 0.05%. Standard fuel rods were fabricated in order to evaluate and calibrate the nondestructive assay device. The agreement of the results from calibration methods was within 0.6%. The precision of the nondestructive assay device was established as approximately 0.6% by repeated measurements of standard rods. The precision was comparable to that estimated by Poisson statistics. A relative difference of 0.77 to 1.5% was found between the nondestructive and chemical determinations on the reactor grade fuel rods

  3. Reports from the Yayoi symposium on quantitative non-destructive evaluation, (1)

    International Nuclear Information System (INIS)

    1990-02-01

    The report consists of four parts. The first part deals with nondestructive evaluation in the nuclear power industry, focusing on in-service inspection in nuclear power plant, eddy current crack detection test of steam generator heat-exchanger tube, and nondestructive test of thin-wall components. The second part discusses inverse problems and quantification for nondestructive evaluation, centering on the identification of defect by boundary element method, quantification by using supersonic wave, defect shape recognition by the electrical potential method, and a neural network applied to crack type recognition. The third part deals with the application of electromagnetic phenomena to nondestructive evaluation, focusing on a superconducting quantum interference device, electromagnetic measurement in the iron industry, and nondestructive measurement of residual stress by magnetic process. The fourth part discusses visualization techniques for nondestructive evaluation, focusing on image processing, neutron radiography, X-ray CT, defect diagnosis by infrared rays, and visualization of magnetic field. (N.K.)

  4. Nondestructive technique application for corrosion evaluation by hydrogen charging of stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Kyung, E-mail: leejink@deu.ac.kr [Department of Mechanical Engineering, Dongeui University, Busan (Korea, Republic of); Bae, Dong Su [Department of Advanced Materials Engineering, Dongeui University, Busan (Korea, Republic of); Lee, Sang Pill; Hwang, Sung Guk [Department of Mechanical Engineering, Dongeui University, Busan (Korea, Republic of); Lee, Joon Hyun [School of Mechanical Engineering, Pusan National University, Busan (Korea, Republic of)

    2016-11-01

    Highlights: • We have studied on the nondestructive technique application for corrosion evaluation by hydrogen charging of stainless steel. An ultrasonic test (UT) is an useful method to evaluate the mechanical properties of material. By measuring the velocity and the attenuation of ultrasonic wave propagating the hydrogen charged stainless steel, the relation of ultrasonic wave and mechanical properties of hydrogen charged 316L stainless steel was discussed. However, in order to evaluate the dynamic behavior of materials, an acoustic emission (AE) technique was applied to investigate the corrosion characteristics of hydrogen charged specimen. Acoustic emission is one of elastic waves caused by dislocation, cracks initiation and propagation within material from loading outside. The waveform of the acoustic emission is different depending on the damage mechanism of material. Lots of AE parameters such as energy, duration time, event and amplitude were used to analyze the dynamic behavior of the hydrogen charged specimen. • A conventional 316L stainless steel was used in this study, and electrochemical treat system for hydrogen charging of the specimen. ASTM (G142) type tensile specimens (diameter 6.0 mm, gage length 28.6 mm) were prepared, and sulfuric acid(H{sub 2}SO{sub 4}) and arsenic trioxide(As{sub 2}O{sub 3}) were used as the electrolyte, and potentiostat(HA 151) supplied the current to platinum wire and specimen. • Tensile strength and attenuation coefficient has a relation to some extent. Therefore, we could estimate the tensile strength and the hydrogen charging time by measuring the attenuation coefficient using ultrasonic wave nondestructively. • Acoustic emission technique was useful to evaluate the dynamic damage because AE parameters of AE event, average energy and average frequency showed various change by external loading at the specimens with and without hydrogen. - Abstract: Caused corrosion by hydrogen on stainless steel using

  5. Potential of multispectral imaging technology for rapid and non-destructive determination of the microbiological quality of beef filets during aerobic storage

    DEFF Research Database (Denmark)

    Panagou, Efstathios Z.; Papadopoulou, Olga; Carstensen, Jens Michael

    2014-01-01

    counts, namely Class 1 (TVC7.0log10CFU/g). Furthermore, PLS regression models were developed to provide quantitative estimations of microbial counts during meat storage. In both cases model validation was implemented with independent experiments at intermediate storage temperatures (2 and 10°C) using....... thermosphacta, and TVC, respectively. The results indicated that multispectral vision technology has significant potential as a rapid and non-destructive technique in assessing the microbiological quality of beef fillets....

  6. Nondestructive testing of pavements and pavement bases (a bibliography with abstracts). Report for 1964--Dec 1975

    International Nuclear Information System (INIS)

    Habercom, G.E. Jr.

    1976-02-01

    Eighty references on nondestructive methods for quality assurance of pavements and pavement bases are presented. Vibration, nuclear activation, radiometry, and acoustic detection are among the various techniques employed

  7. Application of positron annihilation techniques in non-destructive testing

    International Nuclear Information System (INIS)

    Zeng Hui; Chen Zhiqiang; Jiang Jing; Xue Xudong; Wu Yichu; Liang Jianping; Liu Xiangbing; Wang Rongshan

    2014-01-01

    Background: The investigation of the material damage state is very important for industrial application. Most mechanical damage starts with a change in the microstructure of the material. Positron annihilation techniques are very sensitive probes for detecting defects and damage on an atomic scale in materials, which are of great concern in the engineering applications. Additionally they are apparatus of non-destruction, high-sensitivity and easy-use. Purpose: Our goal is to develop a system to exploit new non-destructive testing (NDT) methods using positron annihilation spectroscopy, a powerful tool to detect vacancy-type defects and their chemical environment. Methods: A positron NDT system was designed and constructed by modifying the 'sandwich structure' of sample-source-sample in conventional Doppler broadening and positron lifetime spectrometers. Doppler broadening and positron lifetime spectra of a single sample can be measured and analyzed by subtracting the contribution of a reference sample. Results: The feasibility and reliability of positron NDT system have been tested by analyzing nondestructively deformation and damage caused by mechanical treatment or by irradiation of metal alloys. This system can be used for detecting defects and damage in thick or large-size samples, as well as for measuring the two-dimension distribution of defects in portable, sensitive, fast way. Conclusion: Positron NDT measurement shows changes in real atomic-scale defects prior to changes in the mechanical properties, which are detectable by other methods of NDT, such as ultrasonic testing and eddy current testing. This system can be developed for use in both the laboratory and field in the future. (authors)

  8. Dynamic, nondestructive imaging of a bioengineered vascular graft endothelium.

    Directory of Open Access Journals (Sweden)

    Bryce M Whited

    Full Text Available Bioengineering of vascular grafts holds great potential to address the shortcomings associated with autologous and conventional synthetic vascular grafts used for small diameter grafting procedures. Lumen endothelialization of bioengineered vascular grafts is essential to provide an antithrombogenic graft surface to ensure long-term patency after implantation. Conventional methods used to assess endothelialization in vitro typically involve periodic harvesting of the graft for histological sectioning and staining of the lumen. Endpoint testing methods such as these are effective but do not provide real-time information of endothelial cells in their intact microenvironment, rather only a single time point measurement of endothelium development. Therefore, nondestructive methods are needed to provide dynamic information of graft endothelialization and endothelium maturation in vitro. To address this need, we have developed a nondestructive fiber optic based (FOB imaging method that is capable of dynamic assessment of graft endothelialization without disturbing the graft housed in a bioreactor. In this study we demonstrate the capability of the FOB imaging method to quantify electrospun vascular graft endothelialization, EC detachment, and apoptosis in a nondestructive manner. The electrospun scaffold fiber diameter of the graft lumen was systematically varied and the FOB imaging system was used to noninvasively quantify the affect of topography on graft endothelialization over a 7-day period. Additionally, results demonstrated that the FOB imaging method had a greater imaging penetration depth than that of two-photon microscopy. This imaging method is a powerful tool to optimize vascular grafts and bioreactor conditions in vitro, and can be further adapted to monitor endothelium maturation and response to fluid flow bioreactor preconditioning.

  9. Nondestructive assay of plutonium residue in horizontal storage tanks

    International Nuclear Information System (INIS)

    Marsh, S.F.

    1985-01-01

    Aqueous plutonium recovery and purification processes often involve the temporary storage of plutonium solutions in holding tanks. Because plutonium is known to precipitate from aqueous solutions under certain conditions, there is a continuing need to assay emptied tanks for plutonium residue. A portable gamma spectrometer system, specifically designed for this purpose, provides rapid assay of such plutonium residues in horizontal storage tanks. A means is thus available for the nondestructive analysis of these tanks on a regular schedule to ensure that significant deposits of plutonium are not allowed to accumulate. 5 figs

  10. Concealed identification symbols and nondestructive determination of the identification symbols

    Science.gov (United States)

    Nance, Thomas A.; Gibbs, Kenneth M.

    2014-09-16

    The concealing of one or more identification symbols into a target object and the subsequent determination or reading of such symbols through non-destructive testing is described. The symbols can be concealed in a manner so that they are not visible to the human eye and/or cannot be readily revealed to the human eye without damage or destruction of the target object. The identification symbols can be determined after concealment by e.g., the compilation of multiple X-ray images. As such, the present invention can also provide e.g., a deterrent to theft and the recovery of lost or stolen objects.

  11. Comparison of destructive and nondestructive assay of heterogeneous salt residues

    International Nuclear Information System (INIS)

    Fleissner, J.G.; Hume, M.W.

    1986-01-01

    To study problems associated with nondestructive assay (NDA) measurements of molten salt residues, a joint study was conducted by the Rocky Flats Plant, Golden, CO and Mound Laboratories, Miamisburg, OH. Extensive NDA measurements were made on nine containers of molten salt residues by both Rocky Flats and Mound followed by dissolution and solution quantification at Rocky Flats. Results of this study verify that plutonium and americium can be measured in such salt residues by a new gamma-ray spectral analysis technique coupled with calorimetry. Biases with respect to the segmented gamma-scan technique were noted

  12. Non-destructive analysis of spent nuclear fuel

    International Nuclear Information System (INIS)

    Popovic, D.

    1961-12-01

    Nondestructive analysis of fuel elements dealt with determining the isotope contents which provide information about the burnup level, quantities of fission products and neutron-multiplication properties of the irradiated fuel. Methods for determination of the isotope ratio of the spent fuel are both numerical and experimental. This report deals with the experimental method. This means development of the experimental methods for direct measurement of the isotope content. A number of procedures are described: measurements of α, β and γ activities of the isotopes; measurement of secondary effects of nuclear reactions with thermal neutrons and fast neutrons; measurement of cross sections; detection of prompt and delayed neutrons

  13. A spent fuel assemblies monitoring device by nondestructive analysis 'PYTHON'

    International Nuclear Information System (INIS)

    Saad, M.; Broeskamp, M.; Hahn, H.; Bignan, G.; Boisset, M.; Silie, P.

    1995-01-01

    The monitoring of spent fuel assemblies (16 x 16 UOX) in KWG-reactor pool with the use of non-destructive methods (total Gamma and neutron counting) allow the control of average burn-up and the extremity burn-up. The measurements allow a safety-criticality control before loading the fuel assemblies into the transport casks. A device called PYTHON has been tested and qualified in France. This paper presents a description of the industrial PYTHON device and the results of the measurements. (orig.)

  14. Non-destructive evaluation studies for cultural heritage

    International Nuclear Information System (INIS)

    Jayakumar, T.; Babu Rao, C.; Kumar, Anish; Rajkumar, K.V.; Sharma, G.K.; Raj, Baldev

    2009-01-01

    The results of the nondestructive evaluation studies carried out on the Delhi iron pillar and the musical pillars of the Vithala temple at Hampi, Karnataka are discussed. While studies on Delhi iron pillar were carried out with a primary aim to understand the methodology of fabrication of this pillar, the studies on the musical pillars were carried out to finger print/petroligically characterize the stones used in the construction of the musical pillars and to understand the origin of various sounds generated on tapping of the musical pillars by carrying out various acoustic studies. (author)

  15. Isotope techniques in non-destructive testing of dynamic systems

    International Nuclear Information System (INIS)

    Singh, Gursharan; Pant, H.J.

    1996-01-01

    A few applications of gamma scanning and radiotracer techniques for Non-destructive Testing (NDT) of dynamic systems in chemical and petrochemical industries are briefly discussed in this paper. Examples of gamma scanning inspections carried out for troubleshooting of various types of columns such as vacuum, extraction, separator and rectifier, with trays and packed beds and having diameters from 1 meter to 8.4 meters are given. Radiotracer applications for Residence Time Distribution (RTD) studies on different systems like an aniline production reactor in a chemical industry and a laboratory scale solid-liquid fluidized bed column are mentioned. (author)

  16. Nondestructive detection system of faults in fuses using radioisotope

    International Nuclear Information System (INIS)

    Goncalves, D.

    1973-01-01

    A system is developed to show the viability of non-destructive detection of the faults of explosive safety fuses which are manufactured by Fabrica da Estrela do Ministerio do Exercito. The faults are detected by an ion-chamber based on the variation of the intensity of the beta particles that penetrate the fuse which passes through a collimator. The beta particles are emitted by Strontium-90 + Yttrium-90 encapsulated in either stainless steel or aluminum. The concept of 'bucking Voltage' is applied to differentiate electronically the signal generated by the ion-chamber. (author)

  17. Non-destructive characterization using pulsed fast-thermal neutrons

    International Nuclear Information System (INIS)

    Womble, P.C.

    1995-01-01

    Explosives, illicit drugs, and other contraband materials contain various chemical elements in quantities and ratios that differentiate them from each other and from innocuous substances. Furthermore, the major chemical elements in coal can provide information about various parameters of importance to the coal industry. In both examples, the non-destructive identification of chemical elements can be performed using pulsed fast-thermal neutrons that, through nuclear reactions, excite the nuclei of the various elements. This technique is being currently developed for the dismantling of nuclear weapons classified as trainers, and for the on-line coal bulk analysis. (orig.)

  18. Non-destructive testing and radiation in industry

    International Nuclear Information System (INIS)

    Woodford, C; Ashby, P.

    2001-01-01

    Non-destructive testing (NDT) is a little known discipline which uses non-invasive and passive techniques to investigate the condition of materials and structures. Some of these techniques employ the use of radioisotopes. The penetrating radiations produced by these materials are applied in various ways to obtain the required information. This presentation is an overview of the application of radioisotopes within the scope of NDT. Notwithstanding the well established use of traditional materials, new forms of radioisotopes are being developed which will extend their capabilities

  19. APPARATUS FOR NON-DESTRUCTIVE INSPECTION OF CANTILEVERED MEMBERS

    Science.gov (United States)

    Taylor, E.R.; Mahoney, C.H.; Lay, C.R.

    1961-10-24

    An apparatus for non-destructive inspection of cantilevered members, such as compressor blades, is described. The member under inspection is vibrated with a regulated source of air under pressure. The amplitude of vibration of the member is maintained at its natural frequency. The frequency of vibration of the member is measured. An indication of an excessive decay or erratic shifting in the measured frequency above an allowable hysteretic decay is provided as an indication of a fault in the member. The member is vibrated for a selected test period. (AEC)

  20. Non-destructive beam profile monitor at HIMAC

    International Nuclear Information System (INIS)

    Sato, S.; Araki, N.; Hosaka, M.

    1995-01-01

    Non-destructive profile monitors (NDPM), based on micro-channel plate (MCP), have been developed and installed in both the synchrotron ring and high-energy beam transport (HEBT) line at HIMAC. Beam test using these monitors have been carried out since April of 1995 to investigate a change of vertical beam size in synchrotron and a possibility of observing beam with high energy by one pass. In this paper the measurement system is mainly reported, and the preliminary results are also briefly presented. (author)

  1. Recent Trends in Electromagnetic Non-Destructive Sensing

    Directory of Open Access Journals (Sweden)

    Klara Capova

    2008-01-01

    Full Text Available The paper deals with material electromagnetic non-destructive testing (eNDT with emphasize on eddy current testing (ECT. Various modifications of ECT sensing are compared and discussed from the desired detected signal characteristics point of view. Except of the optimization of usual probe coils arrangements for the concrete applications, the new magnetic sensors as giant magneto-resistance (GMR and spin dependent tunneling (SDT are presented. The advanced ECT sensors are characterized by their sensitivity, frequency range and sensor dimensions

  2. Nondestructive evaluation of reinforced plastics by a radiometric measurement technique

    International Nuclear Information System (INIS)

    Entine, Gerald; Afshari, Sia; Verlinden, Matt

    1990-01-01

    The demand for new high-performance plastics has greatly increased with advances in the performance characteristics of sophisticated reinforced engineering resins. However, conventional methods for the evaluation of the glass and filler contents of reinforced plastics are destructive, labor intensive, and time consuming. We have developed a new instrument, to address this problem, which provides for the rapid, accurate, and nondestructive measurement of glass or filler content in reinforced plastics. This instrument utilizes radiation transmission and scattering techniques for analytical measurement of glass, graphite and other fillers used in reinforced plastics. (author)

  3. Augmented reality application for industrial non-destructive inspection training

    Science.gov (United States)

    Amza, Catalin Gheorghe; Zapciu, Aurelian; Teodorescu, Octav

    2018-02-01

    Such a technology - Augmented Reality (AR) has great potential of use, especially for training purposes of new operators on using expensive equipment. In this context, the paper presents an augmented reality training system developed for phased-array ultrasonic non-destructive testing (NDT) equipment. The application has been developed using Unity 5.6.0 game-engine platform integrated with Vuforia sdk toolkit for devices with Android operating system. The test results performed by several NDT operators showed good results, thus proving the potential of using the application in the industrial field.

  4. Multi-resolution analysis for region of interest extraction in thermographic nondestructive evaluation

    Science.gov (United States)

    Ortiz-Jaramillo, B.; Fandiño Toro, H. A.; Benitez-Restrepo, H. D.; Orjuela-Vargas, S. A.; Castellanos-Domínguez, G.; Philips, W.

    2012-03-01

    Infrared Non-Destructive Testing (INDT) is known as an effective and rapid method for nondestructive inspection. It can detect a broad range of near-surface structuring flaws in metallic and composite components. Those flaws are modeled as a smooth contour centered at peaks of stored thermal energy, termed Regions of Interest (ROI). Dedicated methodologies must detect the presence of those ROIs. In this paper, we present a methodology for ROI extraction in INDT tasks. The methodology deals with the difficulties due to the non-uniform heating. The non-uniform heating affects low spatial/frequencies and hinders the detection of relevant points in the image. In this paper, a methodology for ROI extraction in INDT using multi-resolution analysis is proposed, which is robust to ROI low contrast and non-uniform heating. The former methodology includes local correlation, Gaussian scale analysis and local edge detection. In this methodology local correlation between image and Gaussian window provides interest points related to ROIs. We use a Gaussian window because thermal behavior is well modeled by Gaussian smooth contours. Also, the Gaussian scale is used to analyze details in the image using multi-resolution analysis avoiding low contrast, non-uniform heating and selection of the Gaussian window size. Finally, local edge detection is used to provide a good estimation of the boundaries in the ROI. Thus, we provide a methodology for ROI extraction based on multi-resolution analysis that is better or equal compared with the other dedicate algorithms proposed in the state of art.

  5. Non-destructive prediction of pigment content in lettuce based on visible-NIR spectroscopy.

    Science.gov (United States)

    Steidle Neto, Antonio José; Moura, Lorena de Oliveira; Lopes, Daniela de Carvalho; Carlos, Lanamar de Almeida; Martins, Luma Moreira; Ferraz, Leila de Castro Louback

    2017-05-01

    Lettuce (Lactuca sativa L.) is one of the most important salad vegetables in the world, with a number of head shapes, leaf types and colors. The lettuce pigments play important physiological functions, such as photosynthetic processes and light stress defense, but they also benefit human health because of their antioxidant action and anticarcinogenic properties. In this study three lettuce cultivars were grown under different farming systems, and partial least squares models were built to predict the leaf chlorophyll, carotenoid and anthocyanin content. The three proposed models resulted in high coefficients of determination and variable importance for the projection values, as well as low estimative errors for calibration and external validation datasets. These results confirmed that it is possible to accurately predict chlorophyll, carotenoid and anthocyanin content of green and red lettuces, grown in different farming systems, based on the spectral reflectance from 500 to 1000 nm. The proposed models were adequate for estimating lettuce pigments in a quick and non-destructive way, representing an alternative to conventional measurement methods. Prediction accuracies were improved by using the detrending, smoothing and first derivative pretreatments to the original spectral signatures prior to estimating lettuce chlorophyll, carotenoid and anthocyanin content, respectively. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  6. The Nuclear Renaissance — Implications on Quantitative Nondestructive Evaluations

    Science.gov (United States)

    Matzie, Regis A.

    2007-03-01

    The world demand for energy is growing rapidly, particularly in developing countries that are trying to raise the standard of living for billions of people, many of whom do not even have access to electricity. With this increased energy demand and the high and volatile price of fossil fuels, nuclear energy is experiencing resurgence. This so-called nuclear renaissance is broad based, reaching across Asia, the United States, Europe, as well as selected countries in Africa and South America. Some countries, such as Italy, that have actually turned away from nuclear energy are reconsidering the advisability of this design. This renaissance provides the opportunity to deploy more advanced reactor designs that are operating today, with improved safety, economy, and operations. In this keynote address, I will briefly present three such advanced reactor designs in whose development Westinghouse is participating. These designs include the advanced passive PWR, AP1000, which recently received design certification for the US Nuclear Regulatory Commission; the Pebble Bed Modular reactor (PBMR) which is being demonstrated in South Africa; and the International Reactor Innovative and Secure (IRIS), which was showcased in the US Department of Energy's recently announced Global Nuclear Energy Partnership (GNEP), program. The salient features of these designs that impact future requirements on quantitative nondestructive evaluations will be discussed. Such features as reactor vessel materials, operating temperature regimes, and new geometric configurations will be described, and mention will be made of the impact on quantitative nondestructive evaluation (NDE) approaches.

  7. Development of Yb-169 radiation source for new nondestructive inspection

    International Nuclear Information System (INIS)

    Yamabayashi, Hisamichi

    1994-01-01

    As the nondestructive inspection method for large structures, there has been radiography, and X-ray and γ-ray have been used as the radiation. The transmissivity of radiation through materials changes by the energy of the radiation and the density and thickness of the materials. At present about 880 γ-ray radiography apparatuses are used in Japanese private enterprises, and about 70% of them use 192 Ir γ-ray sources, and about 30% use 60 Co or 137 Cs sources. Recently the defect inspection for the worlded parts of thin wall small tubes and so on have become to be regarded as important, and the 169 Yb source that emits lower energy γ-ray is suitable to the purpose. There are many reports that 169 Yb radiography was applied successfully. As the 169 Yb radiation source, pellets and balls are on the market. 169 Yb is made by the neutron irradiation of 168 Yb in nuclear reactors. The characteristics of 169 Yb, the manufacture of 169 Yb radiation sources and the applicability of 169 Yb radiation sources to nondestructive inspection are reported. Also in Japan, many basic experiments on 169 Yb radiation sources have been carried out, and the irradiation apparatuses are small and light, and the control area can be set small. (K.I.)

  8. The Nuclear Renaissance - Implications on Quantitative Nondestructive Evaluations

    International Nuclear Information System (INIS)

    Matzie, Regis A.

    2007-01-01

    The world demand for energy is growing rapidly, particularly in developing countries that are trying to raise the standard of living for billions of people, many of whom do not even have access to electricity. With this increased energy demand and the high and volatile price of fossil fuels, nuclear energy is experiencing resurgence. This so-called nuclear renaissance is broad based, reaching across Asia, the United States, Europe, as well as selected countries in Africa and South America. Some countries, such as Italy, that have actually turned away from nuclear energy are reconsidering the advisability of this design. This renaissance provides the opportunity to deploy more advanced reactor designs that are operating today, with improved safety, economy, and operations. In this keynote address, I will briefly present three such advanced reactor designs in whose development Westinghouse is participating. These designs include the advanced passive PWR, AP1000, which recently received design certification for the US Nuclear Regulatory Commission; the Pebble Bed Modular reactor (PBMR) which is being demonstrated in South Africa; and the International Reactor Innovative and Secure (IRIS), which was showcased in the US Department of Energy's recently announced Global Nuclear Energy Partnership (GNEP), program. The salient features of these designs that impact future requirements on quantitative nondestructive evaluations will be discussed. Such features as reactor vessel materials, operating temperature regimes, and new geometric configurations will be described, and mention will be made of the impact on quantitative nondestructive evaluation (NDE) approaches

  9. Laser active thermography for non-destructive testing

    International Nuclear Information System (INIS)

    Semerok, A.; Grisolia, C.; Fomichev, S.V.; Thro, P.Y.

    2013-01-01

    Thermography methods have found their applications in different fields of human activity. The non-destructive feature of these methods along with the additional advantage by automated remote control and tests of nuclear installations without personnel attendance in the contaminated zone are of particular interest. Laser active pyrometry and laser lock-in thermography for in situ non-destructive characterization of micrometric layers on graphite substrates from European tokamaks were under extensive experimental and theoretical studies in CEA (France). The studies were aimed to obtain layer characterization with cross-checking the layer thermal contact coefficients determined by active laser pyrometry and lock-in thermography. The experimental installation comprised a Nd-YAG pulsed repetition rate laser (1 Hz - 10 kHz repetition rate frequency, homogeneous spot) and a home-made pyrometer system based on two pyrometers for the temperature measurements in 500 - 2600 K range. For both methods, the layer characterization was provided by the best fit of the experimental results and simulations. The layer thermal contact coefficients determined by both methods were quite comparable. Though there was no gain in the measurements accuracy, lock-in measurements have proved their advantage as being much more rapid. The obtained experimental and theoretical results are presented. Some practical applications and possible improvements of the methods are discussed. (authors)

  10. Nondestructive evaluation of dissipative behavior of reinforced concrete structure

    Energy Technology Data Exchange (ETDEWEB)

    Luong, M.P. [Ecole Polytechnique, LMS, CNRS, 91 - Palaiseau (France)

    2001-07-01

    Current technological developments tend toward increased exploitation of materials strengths and toward tackling extreme loads and environmental actions such as offshore structures subject to wind and wave loading, or buildings in seismic area. Concrete is widely used as a construction material because of its high strength-cost ratio in many applications. Experience of earthquakes and laboratory tests has shown that well designed and detailed reinforced concrete is suitable for earthquake resistant structures. The most severe likely earthquake can be survived if the members are sufficiently ductile to absorb and dissipate seismic energy by inelastic deformation. This requires a designer to assess realistically the acceptable levels of strength and to ensure adequate dissipation. This paper proposes the use of infrared thermography as a nondestructive, noncontact and real-time technique to examine diverse mechanisms of dissipation and to illustrate the onset of damage process, stress concentration and heat dissipation localization in loaded zone. In addition, this technique can be used as a nondestructive method for evaluating the fatigue limit of concrete structure subject to repeated loading.

  11. English-Japanese terms in nondestructive testing specifications

    International Nuclear Information System (INIS)

    1991-01-01

    For technical development, it is the prerequisite to clarify the terms to be used in various fields and their definition, therefore, in various foreign countries, there are some standards on terms in respective fields, and also as international standards, ISO/TC 135 (Non-destructive testing) organized the SC on terms from the beginning of foundation. In JIS, there is the column for corresponding English (for reference), but there is the problem of English and American English. The English used in ISO, BS or EN and ASTM standards in relation to nondestructive testing were collected in every technical field and put in order, and the corresponding English terms were selected. Moreover at this opportunity, the terms having the definition in these international, national and semi-national standards were classified into eight fields, that is, common (approval, quality assurance, defects and others), radiography, ultrasonic flaw detection, acoustic emission, eddy current flaw detection, magnetic flaw detection, liquid penetrant testing and leak test, and the Japanese translation was stipulated. The draft of this standard was approved by the standardization committee on January 17, 1991. (K.I.)

  12. Needs for development in nondestructive testing for advanced reactor systems

    International Nuclear Information System (INIS)

    McClung, R.W.

    1978-01-01

    The needs for development of nondestructive testing (NDT) techniques and equipment were surveyed and analyzed relative to problem areas for the Liquid-Metal Fast Breeder Reactor, the Molten-Salt Breeder Reactor, and the Advanced Gas-Cooled Reactor. The paper first discusses the developmental needs that are broad-based requirements in nondestrutive testing, and the respective methods applicable, in general, to all components and reactor systems. Next, the requirements of generic materials and components that are common to all advanced reactor systems are examined. Generally, nondestructive techniques should be improved to provide better reliability and quantitativeness, improved flaw characterization, and more efficient data processing. Specific recommendations relative to such methods as ultrasonics, eddy currents, acoustic emission, radiography, etc., are made. NDT needs common to all reactors include those related to materials properties and degradation, welds, fuels, piping, steam generators, etc. The scope of applicability ranges from initial design and material development stages through process control and manufacturing inspection to in-service examination

  13. Local defect resonance for sensitive non-destructive testing

    Science.gov (United States)

    Adebahr, W.; Solodov, I.; Rahammer, M.; Gulnizkij, N.; Kreutzbruck, M.

    2016-02-01

    Ultrasonic wave-defect interaction is a background of ultrasound activated techniques for imaging and non-destructive testing (NDT) of materials and industrial components. The interaction, primarily, results in acoustic response of a defect which provides attenuation and scattering of ultrasound used as an indicator of defects in conventional ultrasonic NDT. The derivative ultrasonic-induced effects include e.g. nonlinear, thermal, acousto-optic, etc. responses also applied for NDT and defect imaging. These secondary effects are normally relatively inefficient so that the corresponding NDT techniques require an elevated acoustic power and stand out from conventional ultrasonic NDT counterparts for their specific instrumentation particularly adapted to high-power ultrasonic. In this paper, a consistent way to enhance ultrasonic, optical and thermal defect responses and thus to reduce an ultrasonic power required is suggested by using selective ultrasonic activation of defects based on the concept of local defect resonance (LDR). A strong increase in vibration amplitude at LDR enables to reliably detect and visualize the defect as soon as the driving ultrasonic frequency is matched to the LDR frequency. This also provides a high frequency selectivity of the LDR-based imaging, i.e. an opportunity of detecting a certain defect among a multitude of other defects in material. Some examples are shown how to use LDR in non-destructive testing techniques, like vibrometry, ultrasonic thermography and shearography in order to enhance the sensitivity of defect visualization.

  14. Training guidelines in non-destructive testing techniques

    International Nuclear Information System (INIS)

    1987-02-01

    With the conclusion in 1979 of a successful Agency executed UNDP project in Argentina, whose aim was the establishment of a national non-destructive testing centre, the Agency was asked by other countries in the Latin American and Caribbean Region to evaluate the possibility of transferring this success to the whole region. In 1982, with the financial cooperation of UNFSSTD and UNIDO, a regional project was started with the principal objective of assisting the countries in the region to reinforce autonomous NDT capability through regional cooperation. One essential component of this project has been the harmonization of training through the development and use of course syllabi by the 17 countries now participating in the project. To this end, a Regional Working Group was formed and one of its tasks is the development of these syllabi for the more common NDT methods. This publication is a collection of the training programmes elaborated to date which have so far been followed by some 10,000 persons in the region who have received training in NDT as a direct result of the project. These syllabi take into account the development work done by the International Committee for Non-destructive Testing and many national training programmes, and are meant to be an objective guide to assist in the formation of NDT personnel

  15. Laser active thermography for non-destructive testing

    Science.gov (United States)

    Semerok, A.; Grisolia, C.; Fomichev, S. V.; Thro, P.-Y.

    2013-11-01

    Thermography methods have found their applications in different fields of human activity. The non-destructive feature of these methods along with the additional advantage by automated remote control and tests of nuclear installations without personnel attendance in the contaminated zone are of particular interest. Laser active pyrometry and laser lock-in thermography for in situ non-destructive characterization of micrometric layers on graphite substrates from European tokamaks were under extensive experimental and theoretical studies in CEA (France). The studies were aimed to obtain layer characterization with cross-checking the layer thermal contact coefficients determined by active laser pyrometry and lock-in thermography. The experimental installation comprised a Nd-YAG pulsed repetition rate laser (1 Hz - 10 kHz repetition rate frequency, homogeneous spot) and a home-made pyrometer system based on two pyrometers for the temperature measurements in 500 - 2600 K range. For both methods, the layer characterization was provided by the best fit of the experimental results and simulations. The layer thermal contact coefficients determined by both methods were quite comparable. Though there was no gain in the measurements accuracy, lock-in measurements have proved their advantage as being much more rapid. The obtained experimental and theoretical results are presented. Some practical applications and possible improvements of the methods are discussed.

  16. Potential development of non-destructive assay for nuclear safeguards

    International Nuclear Information System (INIS)

    Benoit, R.; Cuypers, M.; Guardini, S.

    1983-01-01

    After a brief summary on the role of non-destructive assay in safeguarding the nuclear fuel cycle, its evolution from NDA methods development to other areas is illustrated. These areas are essentially: a) the evaluation of the performances of NDA techniques in field conditions; b) introduction of full automation of measurement instrument operation, using interactive microprocessors and of measurement data handling evaluation and retrieval features; c) introduction of the adequate link and compatibility to assure NDA measurement data transfer in an integrated safeguards data evaluation scheme. In this field, the Joint Research Centre (JRC) of the Commission of the European Communities (CEC) is developing and implementing a number of techniques and methodologies allowing an integrated and rational treatment of the large amount of safeguards data produced. In particular for the non-destructive assay measurements and techniques, the JRC has studied and tested methodologies for the automatic generation and validation of data of inventory verification. In order to apply these techniques successfully in field, the JRC has studied the design requirements of NDA data management and evaluation systems. This paper also discusses the functional requirements of an integrated system for NDA safeguards data evaluation

  17. Nondestructive evaluation of dissipative behavior of reinforced concrete structure

    International Nuclear Information System (INIS)

    Luong, M.P.

    2001-01-01

    Current technological developments tend toward increased exploitation of materials strengths and toward tackling extreme loads and environmental actions such as offshore structures subject to wind and wave loading, or buildings in seismic area. Concrete is widely used as a construction material because of its high strength-cost ratio in many applications. Experience of earthquakes and laboratory tests has shown that well designed and detailed reinforced concrete is suitable for earthquake resistant structures. The most severe likely earthquake can be survived if the members are sufficiently ductile to absorb and dissipate seismic energy by inelastic deformation. This requires a designer to assess realistically the acceptable levels of strength and to ensure adequate dissipation. This paper proposes the use of infrared thermography as a nondestructive, noncontact and real-time technique to examine diverse mechanisms of dissipation and to illustrate the onset of damage process, stress concentration and heat dissipation localization in loaded zone. In addition, this technique can be used as a nondestructive method for evaluating the fatigue limit of concrete structure subject to repeated loading

  18. Non-destructive nuclear forensics of radioactive samples

    Energy Technology Data Exchange (ETDEWEB)

    Rogge, R.B. [Canadian Neutron Beam Centre, Chalk River, ON (Canada); Alexander, Q.; Bentoumi, G.; Dimayuga, F. [Atomic Energy of Canada Limited, Chalk River, ON (Canada); Flacau, R. [Canadian Neutron Beam Centre, Chalk River, ON (Canada); Li, G.; Li, L.; Sur, B. [Atomic Energy of Canada Limited, Chalk River, ON (Canada)

    2014-07-01

    It is a matter of public safety and security to be able to examine suspicious packages of unknown origin. If the package is radioactive and sealed (i.e., the radioactive materials contained in the package, including their chemical and physical forms, are unknown), there is a significant risk on how to handle the package and eventually safely dispose of its contents. Within the context of nuclear security, nuclear forensics helps address the key issue of identifying the nature and origin of radioactive and nuclear material in order to improve physical protection measures and prevent future theft or diversion of these materials. Nuclear forensics utilizes analytical techniques, destructive and non-destructive, developed for applications related to nuclear fuel cycles. This paper demonstrates the non-destructive examination techniques that can be used to inspect encapsulated radioactive samples. Results of γ spectroscopy, X-ray spectroscopy, neutron imaging, neutron diffraction, and delayed neutron analysis as applied to an examination of sealed capsules containing unknown radioactive materials are presented. The paper also highlights the value of these techniques to the overall nuclear forensic investigation to determine the origin of these unknown radioactive materials. (author)

  19. Challenges of Non-Destructive Assay Waste Measurement

    International Nuclear Information System (INIS)

    Shull, A.H.

    2003-01-01

    Historically, the Savannah River Site (SRS) routinely produced special nuclear material (SNM), which provided stable measurement conditions for the non-destructive assay (NDA) methods. However, the main mission of SRS has changed from the production of SNM to the processing of waste and material stabilization. Currently, the purpose of processing is to recover the SNM from the waste and stabilization materials, much of which is from other DOE facilities. These missions are usually of a short duration, but require non-destructive assay (NDA) accountability measurements on materials of varying composition and geometric configuration. These missions usually have cost and time constraints, which sometimes require re-application of existing NDA methods to waste measurements. Usually, each new material or re-application of the NDA method to a different SNM campaign requires new standards and timely re-calibration of the method. These constraints provide numerous challenges for the NDA methods, particularly in the area of measurement uncertainty. This paper will discuss the challenges of these situations, mainly from a measurement and statistical point of view and provide some possible solutions to the problems encountered. Specific examples will be discussed for the segmented gamma scanner (SGS), neutron multiplicity counter (NMC) and passive neutron coincidence counter (PNCC), which are some of the most common NDA instruments at SRS

  20. Cost-risk optimization of nondestructive inspection level

    International Nuclear Information System (INIS)

    Johnson, D.P.

    1978-01-01

    This paper develops a quantitative methodology for determining the nondestructive inspection (NDI) level that will result in a minimum cost product considering both type one inspection errors, acceptance of defective material units, and type two inspection errors, rejection of sound material units. This methodology represents an advance over fracture mechanics - nondestructive inspection (FM-NDI) design systems that do not consider type two inspection errors or the pre-inspection material quality. The inputs required for the methodology developed in this paper are (1) the rejection probability as a function of inspection size and imperfection size, (2) the flaw frequency (FF), as a function of imperfection size, (3) the probability of failure given the material unit contains an imperfection of a given size as a function of that given size, (4) the manufacturing cost per material unit, (5) the inspection cost per material unit, and (6) the average cost per failure including indirect costs. Four methods are identified for determining the flaw-frequency and three methods are identified for determining the conditional failure probability (one of these methods is probabilistic fracture mechanics). Methods for determining the rejection probability are discussed elsewhere. The NDI-FF methodology can have significant impact where the cost of failures represents a significant fraction of the manufacturing costs, or when a significant fraction of the components are being rejected by the inspection. (Auth.)