WorldWideScience

Sample records for non-uniform roi beam

  1. On The Dynamic Analysis of Non-Uniform Beams Under Uniformly ...

    African Journals Online (AJOL)

    ... the non-uniform continuous beam was replaced by a non-continuous (discrete) system made up of beam elements. The modified elemental and overall stiffness, and mass matrices, the elemental and overall centripetal acceleration matrices as well as the load vector were derived. Next, the Newmark's direct integration ...

  2. Illumination non-uniformity of spirally wobbling beam in heavy ion fusion

    International Nuclear Information System (INIS)

    Suzuki, T.; Noguchi, K.; Kurosaki, T.; Barada, D.; Kawata, S.; Ma, Y. Y.; Ogoyski, A.I.

    2016-01-01

    In inertial confinement fusion, the driver beam illumination non-uniformity leads a degradation of fusion energy output. The illumination non-uniformity allowed is less than a few percent in inertial fusion target implosion. Heavy ion beam (HIB) accelerator provides a capability to oscillate a beam axis with a high frequency. The wobbling beams may provide a new method to reduce or smooth the beam illumination non-uniformity. In this paper the HIBs wobbling illumination scheme was optimized. (paper)

  3. On natural frequencies of non-uniform beams modulated by finite periodic cells

    International Nuclear Information System (INIS)

    Xu, Yanlong; Zhou, Xiaoling; Wang, Wei; Wang, Longqi; Peng, Fujun; Li, Bin

    2016-01-01

    It is well known that an infinite periodic beam can support flexural wave band gaps. However, in real applications, the number of the periodic cells is always limited. If a uniform beam is replaced by a non-uniform beam with finite periodicity, the vibration changes are vital by mysterious. This paper employs the transfer matrix method (TMM) to study the natural frequencies of the non-uniform beams with modulation by finite periodic cells. The effects of the amounts, cross section ratios, and arrangement forms of the periodic cells on the natural frequencies are explored. The relationship between the natural frequencies of the non-uniform beams with finite periodicity and the band gap boundaries of the corresponding infinite periodic beam is also investigated. Numerical results and conclusions obtained here are favorable for designing beams with good vibration control ability. - Highlights: • The transfer matrix method to study the natural frequencies of the finite periodic non-uniform beams is derived. • The transfer matrix method to study the band gaps of the infinite periodic non-uniform beams is derived. • The effects of the periodic cells on the natural frequencies are explored. • The relationships of the natural frequencies and band gap boundaries are investigated.

  4. On natural frequencies of non-uniform beams modulated by finite periodic cells

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yanlong, E-mail: xuyanlong@nwpu.edu.cn [School of Aeronautics, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China); Zhou, Xiaoling [Shanghai Institute of Aerospace System Engineering, Shanghai 201109 (China); Wang, Wei [School of Aeronautics, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China); Wang, Longqi [School of Civil & Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Peng, Fujun [Shanghai Institute of Aerospace System Engineering, Shanghai 201109 (China); Li, Bin [School of Aeronautics, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China)

    2016-09-23

    It is well known that an infinite periodic beam can support flexural wave band gaps. However, in real applications, the number of the periodic cells is always limited. If a uniform beam is replaced by a non-uniform beam with finite periodicity, the vibration changes are vital by mysterious. This paper employs the transfer matrix method (TMM) to study the natural frequencies of the non-uniform beams with modulation by finite periodic cells. The effects of the amounts, cross section ratios, and arrangement forms of the periodic cells on the natural frequencies are explored. The relationship between the natural frequencies of the non-uniform beams with finite periodicity and the band gap boundaries of the corresponding infinite periodic beam is also investigated. Numerical results and conclusions obtained here are favorable for designing beams with good vibration control ability. - Highlights: • The transfer matrix method to study the natural frequencies of the finite periodic non-uniform beams is derived. • The transfer matrix method to study the band gaps of the infinite periodic non-uniform beams is derived. • The effects of the periodic cells on the natural frequencies are explored. • The relationships of the natural frequencies and band gap boundaries are investigated.

  5. Correction of experimental photon pencil-beams for the effects of non-uniform and non-parallel measurement conditions

    International Nuclear Information System (INIS)

    Ceberg, Crister P.; Bjaerngard, Bengt E.

    1995-01-01

    An approximate experimental determination of photon pencil-beams can be based on the reciprocity theorem. The scatter part of the pencil-beam is then essentially the derivative with respect to the field radius of measured scatter-to-primary ratios in circular fields. Obtained in this way, however, the pencil-beam implicitly carries the influence from the lateral fluence and beam quality variations of the incident photons, as well as the effects of the divergence of the beam. In this work we show how these effects can be corrected for. The procedure was to calculate scatter-to-primary ratios using an analytical expression for the pencil-beam. By disregarding one by one the effects of the divergence and the fluence and beam quality variations, the influence of these effects were separated and quantified. For instance, for a 6 MV beam of 20x20 cm 2 field size, at 20 cm depth and a source distance of 100 cm, the total effect was 3.9%; 2.0% was due to the non-uniform incident profile, 1.0% due to the non-uniform beam quality, and 0.9% due to the divergence of the beam. At a source distance of 400 cm, all these effects were much lower, adding up to a total of 0.3 %. Using calculated correction factors like these, measured scatter-to-primary ratios were then stripped from the effects of non-uniform and non-parallel measurement conditions, and the scatter part of the pencil-beam was determined using the reciprocity theorem without approximations

  6. Dynamic behaviour of non-uniform Bernoulli-Euler beams subjected ...

    African Journals Online (AJOL)

    This paper investigates the dynamics behaviour of non-uniform Bernoulli-Euler beams subjected to concentrated loads ravelling at variable velocities. The solution technique is based on the Generalized Galerkin Method and the use of the generating function of the Bessel function type. The results show that, for all the ...

  7. Enhancement of quasi-static strain energy harvesters using non-uniform cross-section post-buckled beams

    Science.gov (United States)

    Jiao, Pengcheng; Borchani, Wassim; Hasni, Hassene; Lajnef, Nizar

    2017-08-01

    Thanks to their efficiency enhancement systems based on post-buckled structural elements have been extensively used in many applications such as actuation, remote sensing and energy harvesting. The post-buckling snap-through behavior of bilaterally constrained beams has been exploited to create sensing or energy harvesting mechanisms for quasi-static applications. The conversion mechanism has been used to transform low-rate and low-frequency excitations into high-rate motions. Electric energy has been generated from such high-rate motions using piezoelectric transducers. However, lack of control over the post-buckling behavior severely limits the mechanism’s efficiency. This study aims to maximize the levels of harvestable power by controlling the location of snap-throughs along the beam at different buckling transitions. Since the snap-through location cannot be controlled by tuning the geometric properties of a uniform beam, non-uniform cross-sections are examined. An energy-based theoretical model is herein developed to predict the post-buckling response of non-prismatic beams. The total potential energy is minimized under constraints that represent the physical confinement of the beam between the lateral boundaries. The experimentally validated results show that changing the shape and geometric dimensions of non-uniform beams allows for the accurate controlling of the snap-through location at different buckling transitions. A 78.59% improvement in harvested energy levels has been achieved by optimization of beam shape.

  8. Complete mechanical behavior analysis of FG Nano Beam under non-uniform loading using non-local theory

    Science.gov (United States)

    Ghaffari, I.; Parhizkar Yaghoobi, M.; Ghannad, M.

    2018-01-01

    The purpose of this study is to offer a complete solution to analyze the mechanical behavior (bending, buckling and vibration) of Nano-beam under non-uniform loading. Furthermore, the effects of size (nonlocal parameters), non-homogeneity constants, and different boundary conditions are investigated by using this method. The exact solution presented here reduces costs incurred by experiments. In this research, the displacement field obeys the kinematics of the Euler-Bernoulli beam theory and non-local elasticity theory has been used. The governing equations and general boundary conditions are derived for a beam by using energy method. The presented solution enables us to analyze any kind of loading profile and boundary conditions with no limitations. Furthermore, this solution, unlike previous studies, is not a series-solution; hence, there is no limitation prior to existing with the series-solution, nor does it need to check convergence. Based on the developed analytical solution, the influence of size, non-homogeneity and non-uniform loads on bending, buckling and vibration behaviors is discussed. Also, the obtained result is highly accurate and in good agreement with previous research. In theoretical method, the allowable range for non-local parameters can be determined so as to make a major contribution to the reduction of the cost of experiments determining the value of non-local parameters.

  9. Non-uniformly polarized beams across their transverse profiles: an introductory study for undergraduate optics courses

    International Nuclear Information System (INIS)

    Piquero, Gemma; Vargas-Balbuena, Javier

    2004-01-01

    We provide a simple theoretical study of beams non-uniformly polarized across their transverse sections which can be introduced in undergraduate optics courses. In order to generate such beams we propose to use a slightly convergent (or divergent) linearly and uniformly polarized beam impinging on an anisotropic uniaxial material with the beam propagation direction along the optic axis. Analytical expressions for the Jones vector, Stokes parameters, ellipticity and azimuth at each point of the transverse section, perpendicular to the propagation direction, are obtained at the output of this system. By means of these parameters a detailed description of the state of polarization across the transverse profile is given

  10. Beam uniformity of flat top lasers

    Science.gov (United States)

    Chang, Chao; Cramer, Larry; Danielson, Don; Norby, James

    2015-03-01

    Many beams that output from standard commercial lasers are multi-mode, with each mode having a different shape and width. They show an overall non-homogeneous energy distribution across the spot size. There may be satellite structures, halos and other deviations from beam uniformity. However, many scientific, industrial and medical applications require flat top spatial energy distribution, high uniformity in the plateau region, and complete absence of hot spots. Reliable standard methods for the evaluation of beam quality are of great importance. Standard methods are required for correct characterization of the laser for its intended application and for tight quality control in laser manufacturing. The International Organization for Standardization (ISO) has published standard procedures and definitions for this purpose. These procedures have not been widely adopted by commercial laser manufacturers. This is due to the fact that they are unreliable because an unrepresentative single-pixel value can seriously distort the result. We hereby propose a metric of beam uniformity, a way of beam profile visualization, procedures to automatically detect hot spots and beam structures, and application examples in our high energy laser production.

  11. Optical property of few-mode fiber with non-uniform refractive index for cylindrical vector beam generation

    Science.gov (United States)

    Li, Hongye; Wan, Hongdan; Zhang, Zuxing; Sun, Bing; Zhang, Lin

    2016-10-01

    This paper investigates optical properties of few-mode fiber with non-uniform refractive index, namely: the few mode fiber with U-shape refractive index and the two-mode and four-mode few-mode fiber with bent radius. Finite element method is used to analyze the mode distributions based on their non-uniform refractive index. Effective mode control can be achieved through these few mode fibers to achieve vector beam generation. Finally, reflection spectra of a few-mode fiber Bragg grating are calculated theoretically and then measured under different bending conditions. Experimental results are in good accordance with the theoretical ones. These few mode fibers show potential applications in generation of cylindrical vector beam both for optical lasing and sensing systems.

  12. Least-squares dual characterization for ROI assessment in emission tomography

    International Nuclear Information System (INIS)

    Ben Bouallègue, F; Mariano-Goulart, D; Crouzet, J F; Dubois, A; Buvat, I

    2013-01-01

    Our aim is to describe an original method for estimating the statistical properties of regions of interest (ROIs) in emission tomography. Drawn upon the works of Louis on the approximate inverse, we propose a dual formulation of the ROI estimation problem to derive the ROI activity and variance directly from the measured data without any image reconstruction. The method requires the definition of an ROI characteristic function that can be extracted from a co-registered morphological image. This characteristic function can be smoothed to optimize the resolution-variance tradeoff. An iterative procedure is detailed for the solution of the dual problem in the least-squares sense (least-squares dual (LSD) characterization), and a linear extrapolation scheme is described to compensate for sampling partial volume effect and reduce the estimation bias (LSD-ex). LSD and LSD-ex are compared with classical ROI estimation using pixel summation after image reconstruction and with Huesman's method. For this comparison, we used Monte Carlo simulations (GATE simulation tool) of 2D PET data of a Hoffman brain phantom containing three small uniform high-contrast ROIs and a large non-uniform low-contrast ROI. Our results show that the performances of LSD characterization are at least as good as those of the classical methods in terms of root mean square (RMS) error. For the three small tumor regions, LSD-ex allows a reduction in the estimation bias by up to 14%, resulting in a reduction in the RMS error of up to 8.5%, compared with the optimal classical estimation. For the large non-specific region, LSD using appropriate smoothing could intuitively and efficiently handle the resolution-variance tradeoff. (paper)

  13. Least-squares dual characterization for ROI assessment in emission tomography

    Science.gov (United States)

    Ben Bouallègue, F.; Crouzet, J. F.; Dubois, A.; Buvat, I.; Mariano-Goulart, D.

    2013-06-01

    Our aim is to describe an original method for estimating the statistical properties of regions of interest (ROIs) in emission tomography. Drawn upon the works of Louis on the approximate inverse, we propose a dual formulation of the ROI estimation problem to derive the ROI activity and variance directly from the measured data without any image reconstruction. The method requires the definition of an ROI characteristic function that can be extracted from a co-registered morphological image. This characteristic function can be smoothed to optimize the resolution-variance tradeoff. An iterative procedure is detailed for the solution of the dual problem in the least-squares sense (least-squares dual (LSD) characterization), and a linear extrapolation scheme is described to compensate for sampling partial volume effect and reduce the estimation bias (LSD-ex). LSD and LSD-ex are compared with classical ROI estimation using pixel summation after image reconstruction and with Huesman's method. For this comparison, we used Monte Carlo simulations (GATE simulation tool) of 2D PET data of a Hoffman brain phantom containing three small uniform high-contrast ROIs and a large non-uniform low-contrast ROI. Our results show that the performances of LSD characterization are at least as good as those of the classical methods in terms of root mean square (RMS) error. For the three small tumor regions, LSD-ex allows a reduction in the estimation bias by up to 14%, resulting in a reduction in the RMS error of up to 8.5%, compared with the optimal classical estimation. For the large non-specific region, LSD using appropriate smoothing could intuitively and efficiently handle the resolution-variance tradeoff.

  14. Electrical field excitation in non-uniform plasma by a modulated electron beam

    International Nuclear Information System (INIS)

    Anisimov, I.O.; Borisov, O.A.

    2000-01-01

    Excitation of electric fields due to a modulated electron beam in a warm non-uniform plasma is treated for weak beams in warm plasma. It is shown that the maximum electric field magnitude that is reached near the local plasma resonance point depends significantly on the direction of the electron stream motion. In collisional plasma the magnitude of the Langmuir wave that propagates to the subcritical plasma also depends on the direction of the electron stream motion. The motion of the modulated electron stream front results in beatings between oscillations on the modulation frequency and on the local electron plasma frequencies at the initial moment. Later these beatings damp in the supercritical plasma, whereas in the subcritical plasma they are transformed into spatial beatings between the field of the modulated electron stream and the excited Langmuir wave. (orig.)

  15. Calibration of EBT2 film by the PDD method with scanner non-uniformity correction.

    Science.gov (United States)

    Chang, Liyun; Chui, Chen-Shou; Ding, Hueisch-Jy; Hwang, Ing-Ming; Ho, Sheng-Yow

    2012-09-21

    The EBT2 film together with a flatbed scanner is a convenient dosimetry QA tool for verification of clinical radiotherapy treatments. However, it suffers from a relatively high degree of uncertainty and a tedious film calibration process for every new lot of films, including cutting the films into several small pieces, exposing with different doses, restoring them back and selecting the proper region of interest (ROI) for each piece for curve fitting. In this work, we present a percentage depth dose (PDD) method that can accurately calibrate the EBT2 film together with the scanner non-uniformity correction and provide an easy way to perform film dosimetry. All films were scanned before and after the irradiation in one of the two homemade 2 mm thick acrylic frames (one portrait and the other landscape), which was located at a fixed position on the scan bed of an Epson 10 000XL scanner. After the pre-irradiated scan, the film was placed parallel to the beam central axis and sandwiched between six polystyrene plates (5 cm thick each), followed by irradiation of a 20 × 20 cm² 6 MV photon beam. Two different beams on times were used on two different films to deliver a dose to the film ranging from 32 to 320 cGy. After the post-irradiated scan, the net optical densities for a total of 235 points on the beam central axis on the films were auto-extracted and compared with the corresponding depth doses that were calculated through the measurement of a 0.6 cc farmer chamber and the related PDD table to perform the curve fitting. The portrait film location was selected for routine calibration, since the central beam axis on the film is parallel to the scanning direction, where non-uniformity correction is not needed (Ferreira et al 2009 Phys. Med. Biol. 54 1073-85). To perform the scanner non-uniformity calibration, the cross-beam profiles of the film were analysed by referencing the measured profiles from a Profiler™. Finally, to verify our method, the films were

  16. Calibration of EBT2 film by the PDD method with scanner non-uniformity correction

    International Nuclear Information System (INIS)

    Chang Liyun; Ding, Hueisch-Jy; Chui, Chen-Shou; Hwang, Ing-Ming; Ho, Sheng-Yow

    2012-01-01

    The EBT2 film together with a flatbed scanner is a convenient dosimetry QA tool for verification of clinical radiotherapy treatments. However, it suffers from a relatively high degree of uncertainty and a tedious film calibration process for every new lot of films, including cutting the films into several small pieces, exposing with different doses, restoring them back and selecting the proper region of interest (ROI) for each piece for curve fitting. In this work, we present a percentage depth dose (PDD) method that can accurately calibrate the EBT2 film together with the scanner non-uniformity correction and provide an easy way to perform film dosimetry. All films were scanned before and after the irradiation in one of the two homemade 2 mm thick acrylic frames (one portrait and the other landscape), which was located at a fixed position on the scan bed of an Epson 10 000XL scanner. After the pre-irradiated scan, the film was placed parallel to the beam central axis and sandwiched between six polystyrene plates (5 cm thick each), followed by irradiation of a 20 × 20 cm 2 6 MV photon beam. Two different beams on times were used on two different films to deliver a dose to the film ranging from 32 to 320 cGy. After the post-irradiated scan, the net optical densities for a total of 235 points on the beam central axis on the films were auto-extracted and compared with the corresponding depth doses that were calculated through the measurement of a 0.6 cc farmer chamber and the related PDD table to perform the curve fitting. The portrait film location was selected for routine calibration, since the central beam axis on the film is parallel to the scanning direction, where non-uniformity correction is not needed (Ferreira et al 2009 Phys. Med. Biol. 54 1073–85). To perform the scanner non-uniformity calibration, the cross-beam profiles of the film were analysed by referencing the measured profiles from a Profiler™. Finally, to verify our method, the films were

  17. Electron Beam Dose Distribution in the Presence of Non-Uniform Magnetic Field

    Directory of Open Access Journals (Sweden)

    Mohamad Javad Tahmasebi-Birgani

    2014-04-01

    Full Text Available Introduction Magnetic fields are capable of altering the trajectory of electron beams andcan be used in radiation therapy.Theaim of this study was to produce regions with dose enhancement and reduction in the medium. Materials and Methods The NdFeB permanent magnets were arranged on the electron applicator in several configurations. Then, after the passage of the electron beams (9 and 15 MeV Varian 2100C/D through the non-uniform magnetic field, the Percentage Depth Dose(PDDs on central axis and dose profiles in three depths for each energy were measured in a 3D water phantom. Results For all magnet arrangements and for two different energies, the surface dose increment and shift in depth of maximum dose (dmax were observed. In addition, the pattern of dose distribution in buildup region was changed. Measurement of dose profile showed dose localization and spreading in some other regions. Conclusion The results of this study confirms that using magnetic field can alter the dose deposition patterns and as a result can produce dose enhancement as well as dose reduction in the medium using high-energy electron beams. These effects provide dose distribution with arbitrary shapes for use in radiation therapy.

  18. Analytical modeling of large amplitude free vibration of non-uniform beams carrying a both transversely and axially eccentric tip mass

    Science.gov (United States)

    Malaeke, Hasan; Moeenfard, Hamid

    2016-03-01

    The objective of this paper is to study large amplitude flexural-extensional free vibration of non-uniform cantilever beams carrying a both transversely and axially eccentric tip mass. The effects of variable axial force is also taken into account. Hamilton's principle is utilized to obtain the partial differential equations governing the nonlinear vibration of the system as well as the corresponding boundary conditions. A numerical finite difference scheme is proposed to find the natural frequencies and mode shapes of the system which is validated specifically for a beam with linearly varying cross section. Using a single mode approximation in conjunction with the Lagrange method, the governing equations are reduced to a set of two nonlinear ordinary differential equations in terms of end displacement components of the beam which are coupled due to the presence of the transverse eccentricity. These temporal coupled equations are then solved analytically using the multiple time scales perturbation technique. The obtained analytical results are compared with the numerical ones and excellent agreement is observed. The qualitative and quantitative knowledge resulting from this research is expected to enable the study of the effects of eccentric tip mass and non-uniformity on the large amplitude flexural-extensional vibration of beams for improved dynamic performance.

  19. Uniform irradiation system using beam scanning method for cyclotron

    International Nuclear Information System (INIS)

    Agematsu, Takashi; Okumura, Susumu; Arakawa, Kazuo

    1994-03-01

    JAERI AVF-cyclotron is equipped with an ion beam scanner for large area irradiation. The two-dimensional fluence distribution of ion beam obtained using cellulose triacetate film dosimeter was not uniform. This is resulted from the distortion of excitation current for electromagnet of the scanner. So, the beam scanning condition, i.e., the relation between the ion species, the beam profile and the scanning width, was extremely limited to make a good uniformity. We have developed a beam scanning simulator to get fluence distributions by calculation and then compared the simulated distributions with the measured ones. It was revealed that the both of them are in good agreement and the beam scanning condition to get good uniformity was led by using this simulator. On the basis of these results, the power supply of scanner was improved. A good uniformity of beam distribution was available. (author)

  20. Numerical study of chaotic oscillations in the electron beam with virtual cathode in the external non-uniform magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Hramov, Alexander E., E-mail: aeh@nonlin.sgu.r [Faculty of Nonlinear Processes, Saratov State University, 83, Astrakhanskaya, Saratov, 410012 (Russian Federation); Koronovskii, Alexey A., E-mail: alkor@nonlin.sgu.r [Faculty of Nonlinear Processes, Saratov State University, 83, Astrakhanskaya, Saratov, 410012 (Russian Federation); Kurkin, Semen, E-mail: KurkinSA@nonlin.sgu.r [Faculty of Nonlinear Processes, Saratov State University, 83, Astrakhanskaya, Saratov, 410012 (Russian Federation)

    2010-07-05

    In this Letter the results of theoretical investigations of the chaotic microwave oscillator based on the electron beam with a virtual cathode are presented. Nonlinear non-stationary processes in these electron systems are studied by means of numerical analysis of 2.5D model. It was discovered that the non-uniform external magnetic field value controls the dynamical regime of oscillations in the virtual cathode oscillator. The processes of the chaotization of output microwave radiation are described and interpreted from the point of view of the formation and interaction of electron structures (bunches) in the electron beams. The numerical results have shown that the investigated electron system with virtual cathode could be considered as a promising controlled source of wideband chaotic oscillations in the microwave range.

  1. Mechanical analysis of non-uniform bi-directional functionally graded intelligent micro-beams using modified couple stress theory

    Science.gov (United States)

    Bakhshi Khaniki, Hossein; Rajasekaran, Sundaramoorthy

    2018-05-01

    This study develops a comprehensive investigation on mechanical behavior of non-uniform bi-directional functionally graded beam sensors in the framework of modified couple stress theory. Material variation is modelled through both length and thickness directions using power-law, sigmoid and exponential functions. Moreover, beam is assumed with linear, exponential and parabolic cross-section variation through the length using power-law and sigmoid varying functions. Using these assumptions, a general model for microbeams is presented and formulated by employing Hamilton’s principle. Governing equations are solved using a mixed finite element method with Lagrangian interpolation technique, Gaussian quadrature method and Wilson’s Lagrangian multiplier method. It is shown that by using bi-directional functionally graded materials in nonuniform microbeams, mechanical behavior of such structures could be affected noticeably and scale parameter has a significant effect in changing the rigidity of nonuniform bi-directional functionally graded beams.

  2. Irradiation uniformity of spherical targets by multiple uv beams from OMEGA

    International Nuclear Information System (INIS)

    Beich, W.; Dunn, M.; Hutchison, R.

    1984-01-01

    Direct-drive laser fusion demands extremely high levels of irradiation uniformity to ensure uniform compression of spherical targets. The assessment of illumination uniformity of targets irradiated by multiple beams from the OMEGA facility is made with the aid of multiple beams spherical superposition codes, which take into account ray tracing and absorption and a detailed knowledge of the intensity distribution of each beam in the target plane. In this report, recent estimates of the irradiation uniformity achieved with 6 and 12 uv beams of OMEGA will be compared with previous measurements in the IR, and predictions will be made for the uv illumination uniformity achievable with 24 beams of OMEGA

  3. Analytical inversion formula for uniformly attenuated fan-beam projections

    International Nuclear Information System (INIS)

    Weng, Y.; Zeng, G.L.; Gullberg, G.T.

    1997-01-01

    In deriving algorithms to reconstruct single photon emission computed tomography (SPECT) projection data, it is important that the algorithm compensates for photon attenuation in order to obtain quantitative reconstruction results. A convolution backprojection algorithm was derived by Tretiak and Metz to reconstruct two-dimensional (2-D) transaxial slices from uniformly attenuated parallel-beam projections. Using transformation of coordinates, this algorithm can be modified to obtain a formulation useful to reconstruct uniformly attenuated fan-beam projections. Unlike that for parallel-beam projections, this formulation does not produce a filtered backprojection reconstruction algorithm but instead has a formulation that is an inverse integral operator with a spatially varying kernel. This algorithm thus requires more computation time than does the filtered backprojection reconstruction algorithm for the uniformly attenuated parallel-beam case. However, the fan-beam reconstructions demonstrate the same image quality as that of parallel-beam reconstructions

  4. Analytical examination of a spiral beam scanning method for uniform irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Mitsuhiro; Okumura, Susumu; Arakawa, Kazuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A new circular beam scanning method for uniform irradiation of high-energy, intense ion beams over a large area has been developed. A sweeping speed and a trajectory density in a radial direction are kept constant to obtain uniform fluence distribution. A radial position of a beam spot on a target and an angular frequency of the circular motion are expressed by an irrational function of time. The beam is swept continuously, and a beam trajectory becomes spiral. More than 90 % uniformity of the fluence distribution can been achieved over a large area. (author)

  5. Beam halo formation from space-charge dominated beams in uniform focusing channels

    International Nuclear Information System (INIS)

    O'Connell, J.S.; Wangler, T.P.; Mills, R.S.; Crandall, K.R.

    1993-01-01

    In space-charge dominated beams the nonlinear space-charge forces produce a filamentation pattern, which results in a 2-component beam consisting of an inner core and an outer halo. The halo is very prominent in mismatched beams, and the potential for accelerator activation is of concern for a next generation of cw, high-power proton linacs that could be applied for intense neutron generators to process nuclear materials. We present new results about beam halo and the evolution of space-charge dominated beams from multiparticle simulation of initial laminar beams in a uniform linear focusing channel, and from a model consisting of single particle interactions with a uniform-density beam core. We study the energy gain from particle interactions with the space-charge field of the core, and we identify the resonant characteristic of this interaction as the basic cause of the separation of the beam into the two components. We identify three different particle-trajectory types, and we suggest that one of these types may lead to continuous halo growth, even after the halo is removed by collimators

  6. Exact fan-beam and 4π-acquisition cone-beam SPECT algorithms with uniform attenuation correction

    International Nuclear Information System (INIS)

    Tang Qiulin; Zeng, Gengsheng L.; Wu Jiansheng; Gullberg, Grant T.

    2005-01-01

    This paper presents analytical fan-beam and cone-beam reconstruction algorithms that compensate for uniform attenuation in single photon emission computed tomography. First, a fan-beam algorithm is developed by obtaining a relationship between the two-dimensional (2D) Fourier transform of parallel-beam projections and fan-beam projections. Using this relationship, 2D Fourier transforms of equivalent parallel-beam projection data are obtained from the fan-beam projection data. Then a quasioptimal analytical reconstruction algorithm for uniformly attenuated Radon data, developed by Metz and Pan, is used to reconstruct the image. A cone-beam algorithm is developed by extending the fan-beam algorithm to 4π solid angle geometry. The cone-beam algorithm is also an exact algorithm

  7. Skin carcinogenesis following uniform and non-uniform β irradiation

    International Nuclear Information System (INIS)

    Charles, M.W.; Williams, J.P.; Coggle, J.E.

    1989-01-01

    Where workers or the general public may be exposed to ionising radiation, the irradiation is rarely uniform. The risk figures and dose limits recommended by the International Commission on Radiological Protection (ICRP) are based largely on clinical and epidemiological studies of reasonably uniform irradiated organs. The paucity of clinical or experimental data for highly non-uniform exposures has prevented the ICRP from providing adequate recommendations. This weakness has led on a number of occasions to the postulate that highly non-uniform exposures of organs could be 100,000 times more carcinogenic than ICRP risk figures would predict. This so-called ''hot-particle hypothesis'' found little support among reputable radiobiologists, but could not be clearly and definitively refuted on the basis of experiment. An experiment, based on skin tumour induction in mouse skin, is described which was developed to test the hypothesis. The skin of 1200 SAS/4 male mice has been exposed to a range of uniform and non-uniform sources of the β emitter 170 Tm (E max ∼ 1 MeV). Non-uniform exposures were produced using arrays of 32 or 8 2-mm diameter sources distributed over the same 8-cm 2 area as a uniform control source. Average skin doses varied from 2-100 Gy. The results for the non-uniform sources show a 30% reduction in tumour incidence by the 32-point array at the lower mean doses compared with the response from uniform sources. The eight-point array showed an order-of-magnitude reduction in tumour incidence compared to uniform irradiation at low doses. These results, in direct contradiction to the ''hot particle hypothesis'', indicate that non-uniform exposures produce significantly fewer tumours than uniform exposures. (author)

  8. Experimental study on generation of large area uniform electron beam

    International Nuclear Information System (INIS)

    Tang Ying; Yi Aiping; Liu Jingru; Qian Hang; Huang Xin; Yu Li; Su Jiancang; Ding Zhenjie; Ding Yongzhong; Yu Jianguo

    2007-01-01

    In the experiment of gas laser pumped by electron beam, large area uniform electron beam is important to generate high efficiency laser output. The experimental study on generation of large area uniform electron beam with SPG-200 pulsed power generator is introduced. SPG-200 is an all-solid-state components pulsed power generator based on SOS, and its open voltage is more than 350 kV. The cathode have the area of 24 mm x 294 mm, and the anode-cathode(A-C)gap spacing is adjustable from 0 to 49 mm. The electron beam of cathode emission is transported to the laser chamber through the diode pressure foil, which sepa-rates the vacuum chamber from the laser chamber. Velvet and graphite cathodes are studied, each generates large area electron beam. The diode parameters are presented, and the uniformity of e-beam is diagnosed. The experimental results show that the diode voltage of the graphite cathode is 240-280 kV, and the diode current is 0.7-1.8 kA. The diode voltage of the velvet cathode is 200-250 kV, and the diode current is 1.5-1.7 kA. The uniformity of the velvet cathode emission is better than that of the graphite cathode. (authors)

  9. Non-uniform shrinkage of multiple-walled carbon nanotubes under in situ electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Lunxiong [South China Normal University, Brain Science Institute, Guangzhou (China); Xiamen University, China-Australia Joint Laboratory for Functional Nanomaterials and Physics Department, Xiamen (China); Su, Jiangbin [Xiamen University, China-Australia Joint Laboratory for Functional Nanomaterials and Physics Department, Xiamen (China); Chang Zhou University, School of Mathematics and Physics, Changzhou (China); Zhu, Xianfang [Xiamen University, China-Australia Joint Laboratory for Functional Nanomaterials and Physics Department, Xiamen (China)

    2016-10-15

    Instability of multiple-walled carbon nanotubes (MWCNTs) was investigated by in situ transmission electron microscopy at room temperature. Specially, the non-uniform shrinkage of tubes was found: The pristine MWCNT shrank preferentially in its axial direction from the most curved free cap end of the tube, but the shrinkage of the tube diameter was offset by the axial shrinkage: For the complex MWCNT, the two inner MWCNTs also preferentially axially shrank from their most curved cap ends and separated from each other. However, for the effect of the radial pressure from the out walls which enveloped the two inner tubes and the tube amorphization, the two inner tubes were extruded to come close to each other and finally touched again. The new ''evaporation'' and ''diffusion'' mechanisms of carbon atoms as driven by the nano-curvature of CNT and the electron beam-induced athermal activation were suggested to explain the above phenomena. (orig.)

  10. Simulation of therapeutic electron beam tracking through a non-uniform magnetic field using finite element method.

    Science.gov (United States)

    Tahmasebibirgani, Mohammad Javad; Maskani, Reza; Behrooz, Mohammad Ali; Zabihzadeh, Mansour; Shahbazian, Hojatollah; Fatahiasl, Jafar; Chegeni, Nahid

    2017-04-01

    In radiotherapy, megaelectron volt (MeV) electrons are employed for treatment of superficial cancers. Magnetic fields can be used for deflection and deformation of the electron flow. A magnetic field is composed of non-uniform permanent magnets. The primary electrons are not mono-energetic and completely parallel. Calculation of electron beam deflection requires using complex mathematical methods. In this study, a device was made to apply a magnetic field to an electron beam and the path of electrons was simulated in the magnetic field using finite element method. A mini-applicator equipped with two neodymium permanent magnets was designed that enables tuning the distance between magnets. This device was placed in a standard applicator of Varian 2100 CD linear accelerator. The mini-applicator was simulated in CST Studio finite element software. Deflection angle and displacement of the electron beam was calculated after passing through the magnetic field. By determining a 2 to 5cm distance between two poles, various intensities of transverse magnetic field was created. The accelerator head was turned so that the deflected electrons became vertical to the water surface. To measure the displacement of the electron beam, EBT2 GafChromic films were employed. After being exposed, the films were scanned using HP G3010 reflection scanner and their optical density was extracted using programming in MATLAB environment. Displacement of the electron beam was compared with results of simulation after applying the magnetic field. Simulation results of the magnetic field showed good agreement with measured values. Maximum deflection angle for a 12 MeV beam was 32.9° and minimum deflection for 15 MeV was 12.1°. Measurement with the film showed precision of simulation in predicting the amount of displacement in the electron beam. A magnetic mini-applicator was made and simulated using finite element method. Deflection angle and displacement of electron beam were calculated. With

  11. Assessment indices for uniform and non-uniform thermal environments

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Different assessment indices for thermal environments were compared and selected for proper assessment of indoor thermal environments.30 subjects reported their overall thermal sensation,thermal comfort,and thermal acceptability in uniform and non-uniform conditions.The results show that these three assessment indices provide equivalent evaluations in uniform environments.However,overall thermal sensation differs from the other two indices and cannot be used as a proper index for the evaluation of non-uniform environments.The relationship between the percentage and the mean vote for each index is established.

  12. CHF multiplier of subcooled flow boiling for non-uniform heating conditions in swirl tube

    International Nuclear Information System (INIS)

    Inasaka, F.; Nariai, H.

    1994-01-01

    The high heat flux components of fusion reactors, such as divertor plates and beam dumps of neutral beam injectors, are estimated to be subjected to very high heat loads more than 10 MW/m 2 . Critical heat flux (CHF), which determines the upper limit of heat removal, is one of the most important problems in designing cooling systems. For practical applications in cooling systems, subcooled flow boiling in water combined with swirl-flow in tubes with internal twisted tape is thought to be the most superior for CHF characteristics in fusion reactor components, heat by irradiation comes in from one side of the wall, and cooling channel is then under circumferentially non-uniform heating condition. Authors have conducted the experiments on the CHF with internal twisted tapes under circumferentially non-uniform heating conditions and showed that when the intensity of non-uniformity increased, q cH (peak heat flux at burnout under nonuniform heating condition) in tube with internal twisted tape increased above the q c,unif (CHF under uniform heating condition), though the average qualities were the same for both cases. They also showed that this CHF enhancement was not seen in smooth tubes without tape under the same average qualities

  13. Equivalent (uniform) square field sizes of flattening filter free photon beams

    Science.gov (United States)

    Lechner, Wolfgang; Kuess, Peter; Georg, Dietmar; Palmans, Hugo

    2017-10-01

    Various types of treatment units, such as CyberKnife, TomoTherapy and C-arm linear accelerators (LINACs) are operated using flattening filter free (FFF) photon beams. Their reference dosimetry, however, is currently based on codes of practice that provide data which were primarily developed and tested for high-energy photon beams with flattening filter (WFF). The aim of this work was to introduce equivalent uniform square field sizes of FFF beams to serve as a basis of a unified reference dosimetry procedure applicable to all aforementioned FFF machines. For this purpose, in-house determined experimental data together with published data of the ratio of doses at depths of 20 cm and 10 cm in water (D 20,10) were used to characterize the depth dose distribution of 6 and 10 MV WFF and FFF beams. These data were analyzed for field sizes ranging from 2  ×  2 cm2 to 40  ×  40 cm2. A scatter function that takes the lateral profiles of the individual beams into account was fitted to the experimental data. The lateral profiles of the WFF beams were assumed to be uniform, while those of the FFF beams were approximated using fourth or sixth order polynomials. The scatter functions of the FFF beams were recalculated using a uniform lateral profile (the same as the physical profile of the WFF beams), and are henceforth denoted as virtual uniform FFF beams (VUFFF). The field sizes of the VUFFF beams having the same scatter contribution as the corresponding FFF beams at a given field size were defined as the equivalent uniform square field (EQUSF) size. Data from four different LINACs with 18 different beams in total, as well as a CyberKnife beam, were analyzed. The average values of EQUSFs over all investigated LINACs of the conventional 10  ×  10 cm2 reference fields of 6 MV and 10 MV FFF beams for C-arm LINACs and machine-specific reference fields for CyberKnife and TomoTherapy were 9.5 cm, 9 cm, 5.0 cm and 6.5 cm respectively. The

  14. Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction for SPECT

    International Nuclear Information System (INIS)

    Tang Qiulin; Zeng, Gengsheng L; Gullberg, Grant T

    2005-01-01

    In this paper, we developed an analytical fan-beam reconstruction algorithm that compensates for uniform attenuation in SPECT. The new fan-beam algorithm is in the form of backprojection first, then filtering, and is mathematically exact. The algorithm is based on three components. The first one is the established generalized central-slice theorem, which relates the 1D Fourier transform of a set of arbitrary data and the 2D Fourier transform of the backprojected image. The second one is the fact that the backprojection of the fan-beam measurements is identical to the backprojection of the parallel measurements of the same object with the same attenuator. The third one is the stable analytical reconstruction algorithm for uniformly attenuated Radon data, developed by Metz and Pan. The fan-beam algorithm is then extended into a cone-beam reconstruction algorithm, where the orbit of the focal point of the cone-beam imaging geometry is a circle. This orbit geometry does not satisfy Tuy's condition and the obtained cone-beam algorithm is an approximation. In the cone-beam algorithm, the cone-beam data are first backprojected into the 3D image volume; then a slice-by-slice filtering is performed. This slice-by-slice filtering procedure is identical to that of the fan-beam algorithm. Both the fan-beam and cone-beam algorithms are efficient, and computer simulations are presented. The new cone-beam algorithm is compared with Bronnikov's cone-beam algorithm, and it is shown to have better performance with noisy projections

  15. Dual-ROI radionuclide ventriculography

    International Nuclear Information System (INIS)

    Standke, R.; Hoer, G.; Kanemoto, N.; Maul, F.D.

    1981-01-01

    Accurate determination of the left ventricular activity function is the precondition for a quantitative analysis of the ventricular volume function. During the volume reduction period, extra-myocardial tissue penetrates into the ROI of the late diastole. This curve-distorting activity cannot be eliminated by a single-ROI technique. Of the multiple-ROI techniques, the dual-ROI method is the least complex and tedions and involves the least methodological error. At the time of maximum volume change rates, the curve may be distorted if the late diastolic ROI is inaccurately defined. A method is described which uses only the counting rate over the late diastolic ROI and corrects it only on the basis of the counting rate of the late systolic ROI. The time parameters remain uninfluenced by this correction method while the volumetric parameters are corrected. (orig./APR) [de

  16. An energy harvesting solution based on the post-buckling response of non-prismatic slender beams

    Science.gov (United States)

    Jiao, Pengcheng; Borchani, Wassim; Hasni, Hassene; Alavi, Amir H.; Lajnef, Nizar

    2017-04-01

    Systems based on post-buckled structural elements have been extensively used in many applications such as actuation, remote sensing and energy harvesting thanks to their efficiency enhancement. The post-buckling snap- through behavior of bilaterally constrained beams has been used to create an efficient energy harvesting mechanism under quasi-static excitations. The conversion mechanism has been used to transform low-rate and low-frequency excitations into high-rate motions. Electric energy can be generated from such high-rate motions using piezoelectric transducers. However, lack of control over the post-buckling behavior severely limits the mechanism's efficiency. This study aims to maximize the levels of the harvestable power by controlling the location of the snapping point along the beam at different buckling transitions. Since the snap-through location cannot be controlled by tuning the geometry properties of a uniform cross-section beam, non-uniform cross sections are examined. An energy-based theoretical model is herein developed to predict the post-buckling response of non-uniform cross-section beams. The total potential energy is minimized under constraints that represent the physical confinement of the beam between the lateral boundaries. Experimentally validated results show that changing the shape and geometry dimensions of non- uniform cross-section beams allows for the accurate control of the snap-through location at different buckling transitions. A 78.59% increase in harvested energy levels is achieved by optimizing the beam's shape.

  17. An ROI multi-resolution compression method for 3D-HEVC

    Science.gov (United States)

    Ti, Chunli; Guan, Yudong; Xu, Guodong; Teng, Yidan; Miao, Xinyuan

    2017-09-01

    3D High Efficiency Video Coding (3D-HEVC) provides a significant potential on increasing the compression ratio of multi-view RGB-D videos. However, the bit rate still rises dramatically with the improvement of the video resolution, which will bring challenges to the transmission network, especially the mobile network. This paper propose an ROI multi-resolution compression method for 3D-HEVC to better preserve the information in ROI on condition of limited bandwidth. This is realized primarily through ROI extraction and compression multi-resolution preprocessed video as alternative data according to the network conditions. At first, the semantic contours are detected by the modified structured forests to restrain the color textures inside objects. The ROI is then determined utilizing the contour neighborhood along with the face region and foreground area of the scene. Secondly, the RGB-D videos are divided into slices and compressed via 3D-HEVC under different resolutions for selection by the audiences and applications. Afterwards, the reconstructed low-resolution videos from 3D-HEVC encoder are directly up-sampled via Laplace transformation and used to replace the non-ROI areas of the high-resolution videos. Finally, the ROI multi-resolution compressed slices are obtained by compressing the ROI preprocessed videos with 3D-HEVC. The temporal and special details of non-ROI are reduced in the low-resolution videos, so the ROI will be better preserved by the encoder automatically. Experiments indicate that the proposed method can keep the key high-frequency information with subjective significance while the bit rate is reduced.

  18. Classical understanding of electron vortex beams in a uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Han, Yeong Deok [Department of Computer Science and Engineering, Woosuk University, Wanju, Cheonbuk, 565-701 (Korea, Republic of); Choi, Taeseung, E-mail: tschoi@swu.ac.kr [Division of Applied Food System, College of Natural Science, Seoul Women' s University, Seoul 139-774 (Korea, Republic of); School of Computational Sciences, Korea Institute for Advanced Study, Seoul 130-012 (Korea, Republic of)

    2017-04-25

    Recently, interesting observations on electron vortex beams have been made. We propose a classical model that shows vortex-like motion due to suitably-synchronized motion of each electron's cyclotron motion in a uniform magnetic field. It is shown that some basic features of electron vortex beams in a uniform magnetic field, such as azimuthal currents, the relation between energy and kinetic angular momentum, and the parallel-axis theorem are understandable by using this classical model. We also show that the time-dependence of kinetic angular momentum of electron vortex beams could be understood as an effect of a specific nonuniform distribution of classical electrons. - Highlights: • A classical model for electron vortex beams is proposed. • The basic features of azimuthal currents could be understood by using this model. • The kinetic angular momentum of electron vortex beams is intuitively understandable.

  19. Instruction sequence based non-uniform complexity classes

    NARCIS (Netherlands)

    Bergstra, J.A.; Middelburg, C.A.

    2013-01-01

    We present an approach to non-uniform complexity in which single-pass instruction sequences play a key part, and answer various questions that arise from this approach. We introduce several kinds of non-uniform complexity classes. One kind includes a counterpart of the well-known non-uniform

  20. Electrostatic lens to focus an ion beam to uniform density

    International Nuclear Information System (INIS)

    Johnson, C.H.

    1977-01-01

    A focusing lens for an ion beam having a gaussian or similar density profile is described. The lens is constructed to provide an inner zero electrostatic field, and an outer electrostatic field such that ions entering this outer field are deflected by an amount that is a function of their distance from the edge of the inner field. The result is a beam that focuses to uniform density in a manner analogous to that of an optical ring lens. In one embodiment, a conically-shaped network of fine wires is enclosed within a cylindrical anode. The wire net together with the anode produces a voltage field that re-directs the outer particles of the beam while the axial particles pass undeflected through a zero field inside the wire net. The result is a focused beam having a uniform intensity over a given target area and at a given distance from the lens

  1. Sagagd method for the beam shaping of uniform illumination

    International Nuclear Information System (INIS)

    Li Yongping; Chen Dewei; Wang Wei

    2002-01-01

    The simulated annealing algorithm, the genetic and the gradient descent algorithm are retrospectively and successfully amalgamated to optimal design of pure phase element for uniform beams. The process of this method is divided into three steps, first the energy enhancement of the main lobe, then the process to make the top of the main lobe to be smooth and the fringe to be steep, at last the full optimization beam. After these three steps of optimization, the beam is good enough to be applied to ICF

  2. Wide-range frequency selectivity in an acoustic sensor fabricated using a microbeam array with non-uniform thickness

    International Nuclear Information System (INIS)

    Shintaku, Hirofumi; Kotera, Hidetoshi; Kobayashi, Takayuki; Zusho, Kazuki; Kawano, Satoyuki

    2013-01-01

    In this study, we have demonstrated the fabrication of a microbeam array (MBA) with various thicknesses and investigated the suitability it for an acoustic sensor with wide-range frequency selectivity. For this, an MBA composed of 64 beams, with thicknesses varying from 2.99–142 µm, was fabricated by using single gray-scale lithography and a thick negative photoresist. The vibration of the beams in air was measured using a laser Doppler vibrometer; the resonant frequencies of the beams were measured to be from 11.5 to 290 kHz. Lastly, the frequency range of the MBA with non-uniform thickness was 10.9 times that of the MBA with uniform thickness. (paper)

  3. Modelling of Spring Constant and Pull-down Voltage of Non-uniform RF MEMS Cantilever Incorporating Stress Gradient

    Directory of Open Access Journals (Sweden)

    Shimul Chandra SAHA

    2008-11-01

    Full Text Available We have presented a model for spring constant and pull-down voltage of a non-uniform radio frequency microelectromechanical systems (RF MEMS cantilever that works on electrostatic actuation. The residual stress gradient in the beam material that may arise during the fabrication process is also considered in the model. Using basic force deflection calculation of the suspended beam, a stand-alone model for the spring constant and pull-down voltage of the non-uniform cantilever is developed. To compare the model, simulation is performed using standard Finite Element Method (FEM analysis tolls from CoventorWare. The model matches very well with the FEM simulation results. The model will offer an efficient means of design, analysis, and optimization of RF MEMS cantilever switches.

  4. Improvement of uniformity of the negative ion beams by tent-shaped magnetic field in the JT-60 negative ion source

    International Nuclear Information System (INIS)

    Yoshida, Masafumi; Hanada, Masaya; Kojima, Atsushi; Kashiwagi, Mieko; Akino, Noboru; Endo, Yasuei; Komata, Masao; Mogaki, Kazuhiko; Nemoto, Shuji; Ohzeki, Masahiro; Seki, Norikazu; Sasaki, Shunichi; Shimizu, Tatsuo; Terunuma, Yuto; Grisham, Larry R.

    2014-01-01

    Non-uniformity of the negative ion beams in the JT-60 negative ion source with the world-largest ion extraction area was improved by modifying the magnetic filter in the source from the plasma grid (PG) filter to a tent-shaped filter. The magnetic design via electron trajectory calculation showed that the tent-shaped filter was expected to suppress the localization of the primary electrons emitted from the filaments and created uniform plasma with positive ions and atoms of the parent particles for the negative ions. By modifying the magnetic filter to the tent-shaped filter, the uniformity defined as the deviation from the averaged beam intensity was reduced from 14% of the PG filter to ∼10% without a reduction of the negative ion production

  5. Non-Uniform Cathode Emission Studies of a MIG Gun

    Science.gov (United States)

    Marchewka, C. D.; Shapiro, M. A.; Sirigiri, J. R.; Temkin, R. J.

    2004-11-01

    We present the initial results of the modeling of the effect of emission non-uniformity in 96 kV, 40 A Magnetron Injection Gun (MIG) of a 1.5 MW 110 GHz gyrotron using a 3D gun simulation code. The azimuthal emission nonuniformity can lead to increased mode competition and an overall decreased efficiency of the device [1]. The electron beam is modeled from the cathode to a downstream position where the velocity spread saturates using the AMAZE 3D suite of codes. After bench marking the results of the 3D code with 2D codes such as TRAK2D and EGUN, the emitter was modified to simulate asymmetric emission from the cathode to gain an understanding into the effects of inhomogeneous beam current density on the velocity spread and pitch factor of the electron beam. [1] G. S. Nusinovich, A.N. Vlasov, M. Botton, T. M. Antonsen, Jr., S. Cauffman, K. Felch, ``Effect of the azimuthal inhomogeneity of electron emission on gyrotron operation,'' Phys. Plasmas, vol. 8, no. 7, pp. 3473-3479, 2001

  6. Quasiparticles in non-uniformly magnetized plasma

    International Nuclear Information System (INIS)

    Sosenko, P.P.

    1994-01-01

    A quasiparticle concept is generalized for the case of non-uniformly magnetized plasma. Exact and reduced continuity equations for the microscopic density in the quasiparticle phase space are derived, and the nature of quasiparticles is analyzed. The theory is developed for the general case of relativistic particles in electromagnetic fields, besides non-uniform but stationary magnetic fields. Effects of non-stationary magnetic fields are briefly investigated also. 26 refs

  7. Simulation and Experimental Investigations on the Strain Measurement of the Uniform Strength Beam Using a FBG sensor

    International Nuclear Information System (INIS)

    Tu Yumeng; Gong Huaping; Chen Jixuan; Jin Yongxing

    2011-01-01

    The model of force analysis on a uniform strength beam is built by the general finite element program (ANSYS software). The flexivity profile produced by uniform strength beam with different forces is simulated by ANSYS software. In experiment, a fiber Bragg grating sensor is fixed on the uniform strength beam with modified acrylate. The flexivity and strain are varied by changing the load on the end of the beam. The strain of the uniform strength beam is measured with FBG when applied force is varied from 2.45N to14.7N with a step of 2.45N. Both the simulated and experimental results show that, the strain induced by the uniform strength beam is linear with the load force. The sensitivity is 18.32με/N for experimental measurement, and 19.72με/N for simulation. The experimental results are consistent with the simulation results, with the maximum measurement error of strain being 7.4%. It indicates that, the FBG sensor fixed with modified acrylate is proved to be effectively and reliably in the applications of civil engineering.

  8. Commissioning of output factors for uniform scanning proton beams

    International Nuclear Information System (INIS)

    Zheng Yuanshui; Ramirez, Eric; Mascia, Anthony; Ding Xiaoning; Okoth, Benny; Zeidan, Omar; Hsi Wen; Harris, Ben; Schreuder, Andries N.; Keole, Sameer

    2011-01-01

    Purpose: Current commercial treatment planning systems are not able to accurately predict output factors and calculate monitor units for proton fields. Patient-specific field output factors are thus determined by either measurements or empirical modeling based on commissioning data. The objective of this study is to commission output factors for uniform scanning beams utilized at the ProCure proton therapy centers. Methods: Using water phantoms and a plane parallel ionization chamber, the authors first measured output factors with a fixed 10 cm diameter aperture as a function of proton range and modulation width for clinically available proton beams with ranges between 4 and 31.5 cm and modulation widths between 2 and 15 cm. The authors then measured the output factor as a function of collimated field size at various calibration depths for proton beams of various ranges and modulation widths. The authors further examined the dependence of the output factor on the scanning area (i.e., uncollimated proton field), snout position, and phantom material. An empirical model was developed to calculate the output factor for patient-specific fields and the model-predicted output factors were compared to measurements. Results: The output factor increased with proton range and field size, and decreased with modulation width. The scanning area and snout position have a small but non-negligible effect on the output factors. The predicted output factors based on the empirical modeling agreed within 2% of measurements for all prostate treatment fields and within 3% for 98.5% of all treatment fields. Conclusions: Comprehensive measurements at a large subset of available beam conditions are needed to commission output factors for proton therapy beams. The empirical modeling agrees well with the measured output factor data. This investigation indicates that it is possible to accurately predict output factors and thus eliminate or reduce time-consuming patient-specific output

  9. Beam delivery system with a non-digitized diffractive beam splitter for laser-drilling of silicon

    Science.gov (United States)

    Amako, J.; Fujii, E.

    2016-02-01

    We report a beam-delivery system consisting of a non-digitized diffractive beam splitter and a Fourier transform lens. The system is applied to the deep-drilling of silicon using a nanosecond pulse laser in the manufacture of inkjet printer heads. In this process, a circularly polarized pulse beam is divided into an array of uniform beams, which are then delivered precisely to the process points. To meet these requirements, the splitter was designed to be polarization-independent with an efficiency>95%. The optical elements were assembled so as to allow the fine tuning of the effective overall focal length by adjusting the wavefront curvature of the beam. Using the system, a beam alignment accuracy ofbeam array and the throughput was substantially improved (10,000 points on a silicon wafer drilled in ~1 min). This beam-delivery scheme works for a variety of laser applications that require parallel processing.

  10. A stability criterion for HNFDE with non-uniform delays

    International Nuclear Information System (INIS)

    Liu Xingwen; Zhong Shouming; Zhang Fengli

    2005-01-01

    Stability of functional differential equations (FDE) is an increasingly important problem in both science and engineering. Delays, whether uniform or non-uniform, play an important role in the dynamics of a system. Since non-uniform delay is more general and less focused than uniform delay, this paper concentrates on the stability of high-order neutral functional differential equations (HNFDE) with non-uniform delay, and proposes a sufficient condition for it. This result may be widely helpful, thanks to the frequent emergence of a HNFDE with non-uniform delay in various fields. Its effectiveness is illustrated by some examples

  11. Non-uniform sampling of NMR relaxation data

    DEFF Research Database (Denmark)

    Schwarz-Linnet, Troels; Teilum, Kaare

    2016-01-01

    The use of non-uniform sampling of NMR spectra may give significant reductions in the data acquisition time. For quantitative experiments such as the measurement of spin relaxation rates, non-uniform sampling is however not widely used as inaccuracies in peak intensities may lead to errors...... in the extracted dynamic parameters. By systematic reducing the coverage of the Nyquist grid of (15)N Carr-Purcell-Meiboom-Gill (CPMG) relaxation dispersion datasets for four different proteins and performing a full data analysis of the resulting non-uniform sampled datasets, we have compared the performance...... of the multi-dimensional decomposition and iterative re-weighted least-squares algorithms in reconstructing spectra with accurate peak intensities. As long as a single fully sampled spectrum is included in a series of otherwise non-uniform sampled two-dimensional spectra, multi-dimensional decomposition...

  12. Flexural torsional buckling of uniformly compressed beam-like structures

    Science.gov (United States)

    Ferretti, M.

    2018-02-01

    A Timoshenko beam model embedded in a 3D space is introduced for buckling analysis of multi-store buildings, made by rigid floors connected by elastic columns. The beam model is developed via a direct approach, and the constitutive law, accounting for prestress forces, is deduced via a suitable homogenization procedure. The bifurcation analysis for the case of uniformly compressed buildings is then addressed, and numerical results concerning the Timoshenko model are compared with 3D finite element analyses. Finally, some conclusions and perspectives are drawn.

  13. Downsampling Non-Uniformly Sampled Data

    Directory of Open Access Journals (Sweden)

    Fredrik Gustafsson

    2007-10-01

    Full Text Available Decimating a uniformly sampled signal a factor D involves low-pass antialias filtering with normalized cutoff frequency 1/D followed by picking out every Dth sample. Alternatively, decimation can be done in the frequency domain using the fast Fourier transform (FFT algorithm, after zero-padding the signal and truncating the FFT. We outline three approaches to decimate non-uniformly sampled signals, which are all based on interpolation. The interpolation is done in different domains, and the inter-sample behavior does not need to be known. The first one interpolates the signal to a uniformly sampling, after which standard decimation can be applied. The second one interpolates a continuous-time convolution integral, that implements the antialias filter, after which every Dth sample can be picked out. The third frequency domain approach computes an approximate Fourier transform, after which truncation and IFFT give the desired result. Simulations indicate that the second approach is particularly useful. A thorough analysis is therefore performed for this case, using the assumption that the non-uniformly distributed sampling instants are generated by a stochastic process.

  14. Can state-of-the-art HVS-based objective image quality criteria be used for image reconstruction techniques based on ROI analysis?

    Science.gov (United States)

    Dostal, P.; Krasula, L.; Klima, M.

    2012-06-01

    Various image processing techniques in multimedia technology are optimized using visual attention feature of the human visual system. Spatial non-uniformity causes that different locations in an image are of different importance in terms of perception of the image. In other words, the perceived image quality depends mainly on the quality of important locations known as regions of interest. The performance of such techniques is measured by subjective evaluation or objective image quality criteria. Many state-of-the-art objective metrics are based on HVS properties; SSIM, MS-SSIM based on image structural information, VIF based on the information that human brain can ideally gain from the reference image or FSIM utilizing the low-level features to assign the different importance to each location in the image. But still none of these objective metrics utilize the analysis of regions of interest. We solve the question if these objective metrics can be used for effective evaluation of images reconstructed by processing techniques based on ROI analysis utilizing high-level features. In this paper authors show that the state-of-the-art objective metrics do not correlate well with subjective evaluation while the demosaicing based on ROI analysis is used for reconstruction. The ROI were computed from "ground truth" visual attention data. The algorithm combining two known demosaicing techniques on the basis of ROI location is proposed to reconstruct the ROI in fine quality while the rest of image is reconstructed with low quality. The color image reconstructed by this ROI approach was compared with selected demosaicing techniques by objective criteria and subjective testing. The qualitative comparison of the objective and subjective results indicates that the state-of-the-art objective metrics are still not suitable for evaluation image processing techniques based on ROI analysis and new criteria is demanded.

  15. The effects of non-uniform flow velocity on vibrations of single-walled carbon nanotube conveying fluid

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi-Goughari, Moslem [Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Hosseini, Mohammad [Sirjan University of Technology, Sirjan (Iran, Islamic Republic of)

    2015-02-15

    The vibrational behavior of a viscous nanoflow-conveying single-walled carbon nanotube (SWCNT) was investigated. The nonuniformity of the flow velocity distribution caused by the viscosity of fluid and the small-size effects on the flow field was considered. Euler-Bernoulli beam model was used to investigate flow-induced vibration of the nanotube, while the non-uniformity of the flow velocity and the small-size effects of the flow field were formulated through Knudsen number (Kn), as a discriminant parameter. For laminar flow in a circular nanotube, the momentum correction factor was developed as a function of Kn. For Kn = 0 (continuum flow), the momentum correction factor was found to be 1.33, which decreases by the increase in Kn may even reach near 1 for the transition flow regime. We observed that for passage of viscous flow through a nanotube with the non-uniform flow velocity, the critical continuum flow velocity for divergence decreased considerably as opposed to those for the uniform flow velocity, while by increasing Kn, the difference between the uniform and non-uniform flow models may be reduced. In the solution part, the differential transformation method (DTM) was used to solve the governing differential equations of motion.

  16. The effects of non-uniform flow velocity on vibrations of single-walled carbon nanotube conveying fluid

    International Nuclear Information System (INIS)

    Sadeghi-Goughari, Moslem; Hosseini, Mohammad

    2015-01-01

    The vibrational behavior of a viscous nanoflow-conveying single-walled carbon nanotube (SWCNT) was investigated. The nonuniformity of the flow velocity distribution caused by the viscosity of fluid and the small-size effects on the flow field was considered. Euler-Bernoulli beam model was used to investigate flow-induced vibration of the nanotube, while the non-uniformity of the flow velocity and the small-size effects of the flow field were formulated through Knudsen number (Kn), as a discriminant parameter. For laminar flow in a circular nanotube, the momentum correction factor was developed as a function of Kn. For Kn = 0 (continuum flow), the momentum correction factor was found to be 1.33, which decreases by the increase in Kn may even reach near 1 for the transition flow regime. We observed that for passage of viscous flow through a nanotube with the non-uniform flow velocity, the critical continuum flow velocity for divergence decreased considerably as opposed to those for the uniform flow velocity, while by increasing Kn, the difference between the uniform and non-uniform flow models may be reduced. In the solution part, the differential transformation method (DTM) was used to solve the governing differential equations of motion.

  17. Examining the departure in response of non-point detectors due to non-uniform illumination and displacement of effective center

    International Nuclear Information System (INIS)

    Khabaz, Rahim

    2013-01-01

    A mathematical simulation approach based on the general purpose Monte Carlo N-particle transport code MCNP was developed to calculate the departure in reading of the neutron spectrometer instrument from that expected according to the inverse square law. The calculations were performed to evaluate the effects of beam divergence on the response of a 10 in. spherical device equipped with a long BF 3 counter irradiated by 11 mono-energy neutron beams. The necessary geometry correction factor, because of non-uniform illumination, for the calibration of seven polyethylene spheres with several radionuclide neutron sources, i.e. Ra–Be, 241 Am–Be, 241 Am–B and Po–Be sources was also determined. In all calculations, the displacement of effective center from the geometric center of moderating spheres, when used as an instrument for neutron fluence measurement, was quantified. -- Highlights: • The commonly applied method for measuring the energy spectrum of neutron fields is BSS. • One of the problems of the BSS is the geometry correction factor. • This factor is related to the non-uniform illumination of the spectrometer. • At short distances, serious departure was created in reading from the inverse square law. • This study evaluates a Monte Carlo method to calculate this factor and related parameters

  18. Examining the departure in response of non-point detectors due to non-uniform illumination and displacement of effective center

    Energy Technology Data Exchange (ETDEWEB)

    Khabaz, Rahim, E-mail: r.khabaz@gu.ac.ir

    2013-11-11

    A mathematical simulation approach based on the general purpose Monte Carlo N-particle transport code MCNP was developed to calculate the departure in reading of the neutron spectrometer instrument from that expected according to the inverse square law. The calculations were performed to evaluate the effects of beam divergence on the response of a 10 in. spherical device equipped with a long BF{sub 3} counter irradiated by 11 mono-energy neutron beams. The necessary geometry correction factor, because of non-uniform illumination, for the calibration of seven polyethylene spheres with several radionuclide neutron sources, i.e. Ra–Be, {sup 241}Am–Be, {sup 241}Am–B and Po–Be sources was also determined. In all calculations, the displacement of effective center from the geometric center of moderating spheres, when used as an instrument for neutron fluence measurement, was quantified. -- Highlights: • The commonly applied method for measuring the energy spectrum of neutron fields is BSS. • One of the problems of the BSS is the geometry correction factor. • This factor is related to the non-uniform illumination of the spectrometer. • At short distances, serious departure was created in reading from the inverse square law. • This study evaluates a Monte Carlo method to calculate this factor and related parameters.

  19. Alternative methods for evaluation of non-uniformity in nuclear medicine images

    International Nuclear Information System (INIS)

    Rasaneh, S.; Rajabi, H.; Hajizadeh, E.

    2005-01-01

    Non-uniformity test is the most essential in daily quality control procedures of nuclear medicine equipment's. However, the calculation of non-uniformity is hindered due to high level of noise in nuclear medicine data. Non-uniformity may be considered as a type of systematic error while noise is certainly a random error. The present methods of uniformity evaluation are not able to distinguish between systematic and random error and therefore produce incorrect results when noise is significant. In the present study, two hypothetical methods have been tested for evaluation of non-uniformity in nuclear medicine images. Materials and Methods: Using the Monte Carlo method, uniform and non-uniform flood images of different matrix sizes and different counts were generated. The uniformity of the images was calculated using the conventional method and proposed methods. The results were compared with the known non-uniformity data of simulated images. Results: It was observed that the value of integral uniformity never went below the recommended values except in small matrix size of high counts (more than 80 millions counts). The differential uniformity was quite insensitive to the degree of non-uniformity in large matrix size. Matrix size of 64*64 was only found to be suitable for the calculation of differential uniformity. It was observed that in uniform images, a small amount of non-uniformity changes the p-value of Kolmogorov-Smirnov test and noise amplitude of fast fourier transformation test significantly while the conventional methods failed to detect the nonuniformity. Conclusion: The conventional methods do not distinguish noise, which is always present in the data and occasional non-uniformity at low count density. In a uniform intact flood image, the difference between maximum and minimum pixel count (the value of integral uniformity) is much more than the recommended values for non-uniformity. After filtration of image, this difference decreases, but remains high

  20. Return on investment (ROI) proposal preparation guide

    International Nuclear Information System (INIS)

    BOOM, R.J.

    1999-01-01

    Section I: Background Return on Investment (ROI) Proposal Preparation Guide-- Over $1.9M is available to fund fiscal year (FY) 2000 waste minimization projects on the Hanford Site. This money was allocated by the US. Department of Energy Headquarters (DOE-HQ). The U.S. Department of Energy, Richland Operations (RL) and the U.S. Department of Energy, Office of River Protection (ORP) are currently seeking pollution prevention proposals from across the Hanford Site that provide a high return-on-investment (ROI) by reducing waste and associated management costs. Purpose of ROI Training The ROI Proposal Preparation Guide is a tool to assist Hanford waste generators in preparing ROI proposal forms for submittal to RL for funding. The guide describes the requirements for submitting an ROI proposal and provides examples of completed ROI forms. The intent is to assist waste generators in identifying projects that meet the criteria, provide information necessary to complete the ROI forms, and submit a proposal that is eligible to receive funding. This guide accompanies the one-hour training workshop on how to prepare and submit an ROI proposal

  1. A method to measure the mean thickness and non-uniformity of non-uniform thin film by alpha-ray thickness gauge

    International Nuclear Information System (INIS)

    Miyahara, Hiroshi; Yoshida, Makoto; Watanabe, Tamaki

    1977-01-01

    The α-ray thickness gauge is used to measure non-destructively the thicknesses of thin films, and up to the present day, a thin film with uniform thickness is only taken up as the object of α-ray thickness gauge. When the thickness is determined from the displacement between the absorption curves in the presence and absence of thin film, the absorption curve must be displaced in parallel. When many uniform particles were dispersed as sample, the shape of the absorption curve was calculated as the sum of many absorption curves corresponding to the thin films with different thicknesses. By the comparison of the calculated and measured absorption curves, the number of particles, or the mean superficial density can be determined. This means the extension of thickness measurement from uniform to non-uniform films. Furthermore, these particle models being applied to non-uniform thin film, the possibility of measuring the mean thickness and non-uniformity was discussed. As the result, if the maximum difference of the thickness was more than 0.2 mg/cm 2 , the nonuniformity was considered to distinguish by the usual equipment. In this paper, an α-ray thickness gauge using the absorption curve method was treated, but one can apply this easily to an α-ray thickness gauge using α-ray energy spectra before and after the penetration of thin film. (auth.)

  2. Return on investment (ROI) proposal preparation guide

    International Nuclear Information System (INIS)

    Valero, O.J.

    1998-01-01

    The ROI Proposal Preparation Guide is a tool to assist Hanford waste generators in preparing ROI proposal forms for submittal to Department of Energy, Richland Operations Office (DOE/RL) for funding. The guide describes the requirements for submitting an ROI proposal and provides examples of completed ROI forms. The intent is to assist waste generators in identifying projects that meet the criteria, provide information necessary to complete the ROI forms, and submit a proposal that is eligible to receive funding

  3. A mechanical model of a non-uniform ionomeric polymer metal composite actuator

    International Nuclear Information System (INIS)

    Anton, Mart; Aabloo, Alvo; Punning, Andres; Kruusmaa, Maarja

    2008-01-01

    This paper describes a mechanical model of an IPMC (ionomeric polymer metal composite) actuator in a cantilever beam configuration. The main contribution of our model is that it gives the most detailed description reported so far of the quasistatic mechanical behaviour of the actuator with non-uniform bending at large deflections. We also investigate a case where part of an IPMC actuator is replaced with a rigid elongation and demonstrate that this configuration would make the actuator behave more linearly. The model is experimentally validated with MuscleSheet(TM) IPMCs, purchased from BioMimetics Inc

  4. Determining optimum wavelength of ultraviolet rays to pre-exposure of non-uniformity error correction in Gafchromic EBT2 films

    Science.gov (United States)

    Katsuda, Toshizo; Gotanda, Rumi; Gotanda, Tatsuhiro; Akagawa, Takuya; Tanki, Nobuyoshi; Kuwano, Tadao; Noguchi, Atsushi; Yabunaka, Kouichi

    2018-03-01

    Gafchromic films have been used to measure X-ray doses in diagnostic radiology such as computed tomography. The double-exposure technique is used to correct non-uniformity error of Gafchromic EBT2 films. Because of the heel effect of diagnostic x-rays, ultraviolet A (UV-A) is intended to be used as a substitute for x-rays. When using a UV-A light-emitting diode (LED), it is necessary to determine the effective optimal UV wavelength for the active layer of Gafchromic EBT2 films. This study evaluated the relation between the increase in color density of Gafchromic EBT2 films and the UV wavelengths. First, to correct non-uniformity, a Gafchromic EBT2 film was pre-irradiated using uniform UV-A radiation for 60 min from a 72-cm distance. Second, the film was irradiated using a UV-LED with a wavelength of 353-410 nm for 60 min from a 5.3-cm distance. The maximum, minimum, and mean ± standard deviation (SD) of pixel values of the subtraction images were evaluated using 0.5 inches of a circular region of interest (ROI). The highest mean ± SD (8915.25 ± 608.86) of the pixel value was obtained at a wavelength of 375 nm. The results indicated that 375 nm is the most effective and sensitive wavelength of UV-A for Gafchromic EBT2 films and that UV-A can be used as a substitute for x-rays in the double-exposure technique.

  5. Non-Uniformity Correction Using Nonlinear Characteristic Performance Curves for Calibration

    Science.gov (United States)

    Lovejoy, McKenna Roberts

    Infrared imaging is an expansive field with many applications. Advances in infrared technology have lead to a greater demand from both commercial and military sectors. However, a known problem with infrared imaging is its non-uniformity. This non-uniformity stems from the fact that each pixel in an infrared focal plane array has its own photoresponse. Many factors such as exposure time, temperature, and amplifier choice affect how the pixels respond to incoming illumination and thus impact image uniformity. To improve performance non-uniformity correction (NUC) techniques are applied. Standard calibration based techniques commonly use a linear model to approximate the nonlinear response. This often leaves unacceptable levels of residual non-uniformity. Calibration techniques often have to be repeated during use to continually correct the image. In this dissertation alternates to linear NUC algorithms are investigated. The goal of this dissertation is to determine and compare nonlinear non-uniformity correction algorithms. Ideally the results will provide better NUC performance resulting in less residual non-uniformity as well as reduce the need for recalibration. This dissertation will consider new approaches to nonlinear NUC such as higher order polynomials and exponentials. More specifically, a new gain equalization algorithm has been developed. The various nonlinear non-uniformity correction algorithms will be compared with common linear non-uniformity correction algorithms. Performance will be compared based on RMS errors, residual non-uniformity, and the impact quantization has on correction. Performance will be improved by identifying and replacing bad pixels prior to correction. Two bad pixel identification and replacement techniques will be investigated and compared. Performance will be presented in the form of simulation results as well as before and after images taken with short wave infrared cameras. The initial results show, using a third order

  6. A non-uniform expansion mechanical safety model of the stent.

    Science.gov (United States)

    Yang, J; Huang, N; Du, Q

    2009-01-01

    Stents have a serial unstable structure that readily leads to non-uniform expansion. Non-uniform expansion in turn creates a stent safety problem. We explain how a stent may be simplified to a serial unstable structure, and present a method to calculate the non-uniform expansion of the stent on the basis of the serial unstable structure. We propose a safety criterion based on the expansion displacement instead of the strain, and explain that the parameter Rd, the ratio of the maximum displacement of the elements to normal displacement, is meaningful to assess the safety level of the stent. We also examine how laser cutting influences non-uniform expansion. The examples illustrate how to calculate the parameter Rd to assess non-uniform expansion of the stent, and demonstrate how the laser cutting offset and strengthening coefficient of the material influence the stent expansion behaviour. The methods are valuable for assessing stent safety due to non-uniform expansion.

  7. Growth rate of non-thermodynamic emittance of intense electron beams

    International Nuclear Information System (INIS)

    Carlsten, B.E.

    1998-01-01

    The nonlinear free-energy concept has been particularly useful in estimating the emittance growth resulting from any excess energy of electron beams in periodic and uniform channels. However, additional emittance growth, that is geometrical rather than thermodynamic in origin, is induced if the particles have different kinetic energies and axial velocities, which is common for mildly relativistic, very intense electron beams. This effect is especially strong if particles lose or gain significant kinetic energy due to the beam's potential depression, as the beam converges and diverges. In this paper we analyze these geometric emittance growth mechanisms for a uniform, continuous, intense electron beam in a focusing transport channel consisting of discrete solenoidal magnets, over distances short enough that the beam does not reach equilibrium. These emittance growth mechanisms are based on the effects of (1) energy variations leading to nonlinearities in the space-charge force even if the current density is uniform, (2) an axial velocity shear radially along the beam due to the beam's azimuthal motion in the solenoids, and (3) an energy redistribution of the beam as the beam compresses or expands. The geometric emittance growth is compared in magnitude with that resulting from the nonlinear free energy, for the case of a mismatched beam in a uniform channel, and is shown to dominate for certain experimental conditions. Rules for minimizing the emittance along a beamline are outlined. copyright 1998 The American Physical Society

  8. Medical Ultrasound Video Coding with H.265/HEVC Based on ROI Extraction.

    Science.gov (United States)

    Wu, Yueying; Liu, Pengyu; Gao, Yuan; Jia, Kebin

    2016-01-01

    High-efficiency video compression technology is of primary importance to the storage and transmission of digital medical video in modern medical communication systems. To further improve the compression performance of medical ultrasound video, two innovative technologies based on diagnostic region-of-interest (ROI) extraction using the high efficiency video coding (H.265/HEVC) standard are presented in this paper. First, an effective ROI extraction algorithm based on image textural features is proposed to strengthen the applicability of ROI detection results in the H.265/HEVC quad-tree coding structure. Second, a hierarchical coding method based on transform coefficient adjustment and a quantization parameter (QP) selection process is designed to implement the otherness encoding for ROIs and non-ROIs. Experimental results demonstrate that the proposed optimization strategy significantly improves the coding performance by achieving a BD-BR reduction of 13.52% and a BD-PSNR gain of 1.16 dB on average compared to H.265/HEVC (HM15.0). The proposed medical video coding algorithm is expected to satisfy low bit-rate compression requirements for modern medical communication systems.

  9. Medical Ultrasound Video Coding with H.265/HEVC Based on ROI Extraction.

    Directory of Open Access Journals (Sweden)

    Yueying Wu

    Full Text Available High-efficiency video compression technology is of primary importance to the storage and transmission of digital medical video in modern medical communication systems. To further improve the compression performance of medical ultrasound video, two innovative technologies based on diagnostic region-of-interest (ROI extraction using the high efficiency video coding (H.265/HEVC standard are presented in this paper. First, an effective ROI extraction algorithm based on image textural features is proposed to strengthen the applicability of ROI detection results in the H.265/HEVC quad-tree coding structure. Second, a hierarchical coding method based on transform coefficient adjustment and a quantization parameter (QP selection process is designed to implement the otherness encoding for ROIs and non-ROIs. Experimental results demonstrate that the proposed optimization strategy significantly improves the coding performance by achieving a BD-BR reduction of 13.52% and a BD-PSNR gain of 1.16 dB on average compared to H.265/HEVC (HM15.0. The proposed medical video coding algorithm is expected to satisfy low bit-rate compression requirements for modern medical communication systems.

  10. Analysis of A Uniform Bernoulli – Euler Beam on Winkler Foundation ...

    African Journals Online (AJOL)

    ADOWIE PERE

    2018-03-09

    Mar 9, 2018 ... method to analyze Winkler foundation subjected to a harmonic moving load on a uniform Bernoulli – Euler Beam. MATLAB software was used to implement the Newmark time integration method to ... A lot of engineering structures under moving loads .... Because numerical procedure produce stability issue,.

  11. Experimental study on the CHF in uniformly and non-uniformly heated vertical annuli

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Se Young; Moon, Sang Ki; Chung, Heung June; Park, Jong Kuk; Kim, Bok Deuk; Youn, Young Jung; Chung, Moon Ki

    2001-09-01

    Up to now, KAERI has performed critical heat flux experiments in water under zero-flow and low-flow conditions using a RCS CHF loop facility with uniformly and non-uniformly heated vertical annulus. Since the existing CHF experiments were mainly performed under low-pressure conditions, we performed the CHF experiment to investigate the pressure effect on the CHF under zero-flow and low-flow conditions for a wide range of system pressures. Also, two vertical annuli with the same geometry have been used to investigate the axial heat flux distributions on the CHF. This report summarizes the experimental results and provides the CHF data that can be used for the development for CHF correlation and a thermal hydraulic analysis code. The CHF data have been collected for system pressures ranging from 0.57 to 15.15 MPa, mass flux 0 and from 200 to 650 kg/m2s, inlet subcooling from 75 to 360 kJ/kg and exit quality from 0.07 to 0.57. At low-flow conditions, the total number of data are 242 and 290 with uniformly heated- and non-uniformly heated test sections, respectively. 41 and 94 CHF data are generated with uniformly heated- and non-uniformly heated test sections, respectively, in zero-flow CHF experiments that are performed by blocking test section bottoms. The CHF experiment result shows that the effects of system pressure, mass flux and inlet subcooling are consistent with conventional understandings and similar to those for round tubes. The behavior of the CHF is relatively complex at low pressures. Also, the effects of axial heat flux profile are large at low-pressure conditions.

  12. Experimental study on the CHF in uniformly and non-uniformly heated vertical annuli

    International Nuclear Information System (INIS)

    Chun, Se Young; Moon, Sang Ki; Chung, Heung June; Park, Jong Kuk; Kim, Bok Deuk; Youn, Young Jung; Chung, Moon Ki

    2001-09-01

    Up to now, KAERI has performed critical heat flux experiments in water under zero-flow and low-flow conditions using a RCS CHF loop facility with uniformly and non-uniformly heated vertical annulus. Since the existing CHF experiments were mainly performed under low-pressure conditions, we performed the CHF experiment to investigate the pressure effect on the CHF under zero-flow and low-flow conditions for a wide range of system pressures. Also, two vertical annuli with the same geometry have been used to investigate the axial heat flux distributions on the CHF. This report summarizes the experimental results and provides the CHF data that can be used for the development for CHF correlation and a thermal hydraulic analysis code. The CHF data have been collected for system pressures ranging from 0.57 to 15.15 MPa, mass flux 0 and from 200 to 650 kg/m2s, inlet subcooling from 75 to 360 kJ/kg and exit quality from 0.07 to 0.57. At low-flow conditions, the total number of data are 242 and 290 with uniformly heated- and non-uniformly heated test sections, respectively. 41 and 94 CHF data are generated with uniformly heated- and non-uniformly heated test sections, respectively, in zero-flow CHF experiments that are performed by blocking test section bottoms. The CHF experiment result shows that the effects of system pressure, mass flux and inlet subcooling are consistent with conventional understandings and similar to those for round tubes. The behavior of the CHF is relatively complex at low pressures. Also, the effects of axial heat flux profile are large at low-pressure conditions

  13. ELECTRONIC CIRCUIT BOARDS NON-UNIFORM COOLING SYSTEM MODEL

    Directory of Open Access Journals (Sweden)

    D. V. Yevdulov

    2016-01-01

    Full Text Available Abstract. The paper considers a mathematical model of non-uniform cooling of electronic circuit boards. The block diagram of the system implementing this approach, the method of calculation of the electronic board temperature field, as well as the principle of its thermal performance optimizing are presented. In the considered scheme the main heat elimination from electronic board is produced by the radiator system, and additional cooling of the most temperature-sensitive components is produced by thermoelectric batteries. Are given the two-dimensional temperature fields of the electronic board during its uniform and non-uniform cooling, is carried out their comparison. As follows from the calculations results, when using a uniform overall cooling of electronic unit there is a waste of energy for the cooling 0f electronic board parts which temperature is within acceptable temperature range without the cooling system. This approach leads to the increase in the cooling capacity of used thermoelectric batteries in comparison with the desired values. This largely reduces the efficiency of heat elimination system. The use for electronic boards cooling of non-uniform local heat elimination removes this disadvantage. The obtained dependences show that in this case, the energy required to create a given temperature is smaller than when using a common uniform cooling. In this approach the temperature field of the electronic board is more uniform and the cooling is more efficient. 

  14. Non-uniformity Correction of Infrared Images by Midway Equalization

    Directory of Open Access Journals (Sweden)

    Yohann Tendero

    2012-07-01

    Full Text Available The non-uniformity is a time-dependent noise caused by the lack of sensor equalization. We present here the detailed algorithm and on line demo of the non-uniformity correction method by midway infrared equalization. This method was designed to suit infrared images. Nevertheless, it can be applied to images produced for example by scanners, or by push-broom satellites. The obtained single image method works on static images, is fully automatic, having no user parameter, and requires no registration. It needs no camera motion compensation, no closed aperture sensor equalization and is able to correct for a fully non-linear non-uniformity.

  15. Below-threshold harmonic generation from strong non-uniform fields

    Science.gov (United States)

    Yavuz, I.

    2017-10-01

    Strong-field photoemission below the ionization threshold is a rich/complex region where atomic emission and harmonic generation may coexist. We studied the mechanism of below-threshold harmonics (BTH) from spatially non-uniform local fields near the metallic nanostructures. Discrete harmonics are generated due to the broken inversion symmetry, suggesting enriched coherent emission in the vuv frequency range. Through the numerical solution of the time-dependent Schrödinger equation, we investigate wavelength and intensity dependence of BTH. Wavelength dependence identifies counter-regular resonances; individual contributions from the multi-photon emission and channel-closing effects due to quantum path interferences. In order to understand the underlying mechanism of BTH, we devised a generalized semi-classical model, including the influence of Coulomb and non-uniform field interactions. As in uniform fields, Coulomb potential in non-uniform fields is the determinant of BTH; we observed that the generation of BTH are due to returning trajectories with negative energies. Due to large distance effectiveness of the non-uniformity, only long trajectories are noticeably affected.

  16. Nanosecond laser texturing of uniformly and non-uniformly wettable micro structured metal surfaces for enhanced boiling heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Zupančič, Matevž, E-mail: matevz.zupancic@fs.uni-lj.si; Može, Matic; Gregorčič, Peter; Golobič, Iztok

    2017-03-31

    Highlights: • Surfaces with periodically changed wettability were produced by a ns marking laser. • Heat transfer was investigated on uniformly and non-uniformly wettable surfaces. • Microporous surfaces with non-uniform wettability enhance boiling heat transfer. • The most bubble nucleations were observed in the vicinity of the microcavities. • Results agree with the predictions of the nucleation criteria. - Abstract: Microstructured uniformly and non-uniformly wettable surfaces were created on 25-μm-thin stainless steel foils by laser texturing using a marking nanosecond Nd:YAG laser (λ = 1064 nm) and utilizing various laser fluences and scan line separations. High-speed photography and high-speed IR thermography were used to investigate nucleate boiling heat transfer on the microstructured surfaces. The most pronounced results were obtained on a surface with non-uniform microstructure and non-uniform wettability. The obtained results show up to a 110% higher heat transfer coefficients and 20–40 times higher nucleation site densities compared to the untextured surface. We show that the number of active nucleation sites is significantly increased in the vicinity of microcavities that appeared in areas with the smallest (10 μm) scan line separation. Furthermore, this confirms the predictions of nucleation criteria and proves that straightforward, cost-effective nanosecond laser texturing allows the production of cavities with diameters of up to a few micrometers and surfaces with non-uniform wettability. Additionally, this opens up important possibilities for a more deterministic control over the complex boiling process.

  17. Absence of internal tidal beams due to non-uniform stratification

    NARCIS (Netherlands)

    Gerkema, T.; van Haren, H.

    2012-01-01

    A linear internal-tide generation model is applied to the Faeroe–Shetland Channel, using observed profiles of stratification. Several degrees of simplification are considered: 1) uniform, i.e. constant N; 2) vertically varying N (z); 3) the full N(x, z) and associated geostrophic background flows.

  18. Spiral wobbling beam illumination uniformity in HIF fuel target implosion

    Directory of Open Access Journals (Sweden)

    Kawata S.

    2013-11-01

    Full Text Available A few % wobbling-beam illumination nonuniformity is realized in heavy ion inertial confinement fusion (HIF throughout the heavy ion beam (HIB driver pulse by a newly introduced spiraling beam axis motion in the first two rotations. The wobbling HIB illumination was proposed to realize a uniform implosion in HIF. However, the initial imprint of the wobbling HIBs was a serious problem and introduces a large unacceptable energy deposition nonuniformity. In the wobbling HIBs illumination, the illumination nonuniformity oscillates in time and space. The oscillating-HIB energy deposition may produce a time-dependent implosion acceleration, which reduces the Rayleigh-Taylor (R-T growth [Laser Part. Beams 11, 757 (1993, Nuclear Inst. Methods in Phys. Res. A 606, 152 (2009, Phys. Plasmas 19, 024503 (2012] and the implosion nonuniformity. The wobbling HIBs can be generated in HIB accelerators and the oscillating frequency may be several 100 MHz ∼ 1 GHz [Phys. Rev. Lett. 104, 254801 (2010]. Three-dimensional HIBs illumination computations present that the few % wobbling HIBs illumination nonuniformity oscillates with the same wobbling HIBs frequency.

  19. A non-uniform three-gap buncher cavity with suppression of transverse-electromagnetic mode leakage in the triaxial klystron amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Zumin; Zhang, Jun, E-mail: zhangjun-nudt@126.com; Zhong, Huihuang; Zhu, Danni; Qiu, Yongfeng [College of Optoelectric Science and Engineering, National University of Defense Technology, Changsha, Hunan 410073 (China)

    2014-01-15

    The triaxial klystron amplifier is an efficient high power relativistic klystron amplifier operating at high frequencies due to its coaxial structure with large radius. However, the coaxial structures result in coupling problems among the cavities as the TEM mode is not cut-off in the coaxial tube. Therefore, the suppression of the TEM mode leakage, especially the leakage from the buncher cavity to the input cavity, is crucial in the design of a triaxial klystron amplifier. In this paper, a non-uniform three-gap buncher cavity is proposed to suppress the TEM mode leakage. The cold cavity analysis shows that the non-uniform three-gap buncher cavity can significantly suppress the TEM mode generation compared to a uniform three-gap buncher cavity. Particle-in-cell simulation shows that the power leakage to the input cavity is less than 1.5‰ of the negative power in the buncher cavity and the buncher cavity can efficiently modulate an intense relativistic electron beam free of self-oscillations. A fundamental current modulation depth of 117% is achieved by employing the proposed non-uniform buncher cavity into an X-band triaxial amplifier, which results in the high efficiency generation of high power microwave.

  20. Non-uniform tube representation of proteins

    DEFF Research Database (Denmark)

    Hansen, Mikael Sonne

    Treating the full protein structure is often neither computationally nor physically possible. Instead one is forced to consider various reduced models capturing the properties of interest. Previous work have used tubular neighborhoods of the C-alpha backbone. However, assigning a unique radius...... might not correctly capture volume exclusion - of crucial importance when trying to understand a proteins $3$d-structure. We propose a new reduced model treating the protein as a non-uniform tube with a radius reflecting the positions of atoms. The tube representation is well suited considering X......-ray crystallographic resolution ~ 3Å while a varying radius accounts for the different sizes of side chains. Such a non-uniform tube better capture the protein geometry and has numerous applications in structural/computational biology from the classification of protein structures to sequence-structure prediction....

  1. Improving the quality factor of an RF spiral inductor with non-uniform metal width and non-uniform coil spacing

    International Nuclear Information System (INIS)

    Shen Pei; Zhang Wanrong; Huang Lu; Jin Dongyue; Xie Hongyun

    2011-01-01

    An improved inductor layout with non-uniform metal width and non-uniform spacing is proposed to increase the quality factor (Q factor). For this inductor layout, from outer coil to inner coil, the metal width is reduced by an arithmetic-progression step, while the metal spacing is increased by a geometric-progression step. An improved layout with variable width and changed spacing is of benefit to the Q factor of RF spiral inductor improvement (approximately 42.86%), mainly due to the suppression of eddy-current loss by weakening the current crowding effect in the center of the spiral inductor. In order to increase the Q factor further, for the novel inductor, a patterned ground shield is used with optimized layout together. The results indicate that, in the range of 0.5 to 16 GHz, the Q factor of the novel inductor is at an optimum, which improves by 67% more than conventional inductors with uniform geometry dimensions (equal width and equal spacing), is enhanced by nearly 23% more than a PGS inductor with uniform geometry dimensions, and improves by almost 20% more than an inductor with an improved layout. (semiconductor devices)

  2. Temporal high-pass non-uniformity correction algorithm based on grayscale mapping and hardware implementation

    Science.gov (United States)

    Jin, Minglei; Jin, Weiqi; Li, Yiyang; Li, Shuo

    2015-08-01

    In this paper, we propose a novel scene-based non-uniformity correction algorithm for infrared image processing-temporal high-pass non-uniformity correction algorithm based on grayscale mapping (THP and GM). The main sources of non-uniformity are: (1) detector fabrication inaccuracies; (2) non-linearity and variations in the read-out electronics and (3) optical path effects. The non-uniformity will be reduced by non-uniformity correction (NUC) algorithms. The NUC algorithms are often divided into calibration-based non-uniformity correction (CBNUC) algorithms and scene-based non-uniformity correction (SBNUC) algorithms. As non-uniformity drifts temporally, CBNUC algorithms must be repeated by inserting a uniform radiation source which SBNUC algorithms do not need into the view, so the SBNUC algorithm becomes an essential part of infrared imaging system. The SBNUC algorithms' poor robustness often leads two defects: artifacts and over-correction, meanwhile due to complicated calculation process and large storage consumption, hardware implementation of the SBNUC algorithms is difficult, especially in Field Programmable Gate Array (FPGA) platform. The THP and GM algorithm proposed in this paper can eliminate the non-uniformity without causing defects. The hardware implementation of the algorithm only based on FPGA has two advantages: (1) low resources consumption, and (2) small hardware delay: less than 20 lines, it can be transplanted to a variety of infrared detectors equipped with FPGA image processing module, it can reduce the stripe non-uniformity and the ripple non-uniformity.

  3. A non-docking intraoperative electron beam applicator system

    International Nuclear Information System (INIS)

    Palta, J.R.; Suntharalingam, N.

    1989-01-01

    A non-docking intraoperative radiation therapy electron beam applicator system for a linear accelerator has been designed to minimize the mechanical, electrical, and tumor visualization problems associated with a docking system. A number of technical innovations have been used in the design of this system. These include: (a) a new intraoperative radiation therapy cone design that gives a better dose uniformity in the treatment volume at all depths; (b) a collimation system which reduces the leakage radiation dose to tissues outside the intraoperative radiation therapy cone; (c) a non-docking system with a translational accuracy of 2 mm and a rotational accuracy of 0.5 degrees; and (d) a rigid clamping system for the cones. A comprehensive set of dosimetric characteristics of the intraoperative radiation therapy applicator system is presented

  4. Development of the systems for uniform target irradiation

    International Nuclear Information System (INIS)

    Voronin, A.Yu.; Garanin, S.G.; Derkach, V.N.; Zhidkov, N.V.; Kravchenko, A.G.; Petrazhitskaya, N.A.; Starodubtsev, K.V.; Sukharev, S.A.; Shnyagin, R.A.

    2010-01-01

    Complete text of publication follows. The new devices have been developed for laser beams homogenizing in the focal spot - multi-component lens raster and raster with the edges smoothing phase mask. The envelope non-uniformity of -4 radians. Investigation into the temporary-spatial smoothing with the use of low-density foams with the density less than the critical one is still in progress. Experiments on the foams with the density of 1-2.3 mg/cm 3 , thickness of 100-200 μm, and the cells' sizes up to the tens of micrometers were carried out with the radiation wavelength of 0.657 μm. The RMS non-uniformity < 5% has been found for the beam passed through the foam. The non-uniformity is evenly distributed over the spatial frequency spectrum. The induced divergence of radiation is measured to be 0.35 radian. The frequency of the rearranged speckled field of about 2 THz was obtained. The beam smoothing was recorded from the start of pulse of radiation, had the duration up to 1 ns, and the width of the radiation spectrum was about 30 A. The work was performed in part under the sponsorship of the RFFI (grants No. 09-02-12157-ofi-m and No. 09-02-97095-r-povolzh'ye-a) and grant of the President of the RF to leading scientific schools No. 65192.2010.2.

  5. Uniform irradiation using rotational-linear scanning method for narrow synchrotron radiation beam

    International Nuclear Information System (INIS)

    Nariyama, N.; Ohnishi, S.; Odano, N.

    2004-01-01

    At SPring-8, photon intensity monitors for synchrotron radiation have been developed. Using these monitors, the responses of radiation detectors and dosimeters to monoenergetic photons can be measured. In most cases, uniform irradiation to the sample is necessary. Here, two scanning methods are proposed. One is an XZ-linear scanning method, which moves the sample simultaneously in both the X and Z direction, that is, in zigzag fashion. The other is a rotational-linear scanning method, which rotates the sample moving in the X direction. To investigate the validity of the two methods, thermoluminescent dosimeters were irradiated with a broad synchrotron-radiation beam, and the readings from the two methods were compared with that of the dosimeters fixed in the beam. The results for both scanning methods virtually agreed with that of the fixed method. The advantages of the rotational-linear scanning method are that low- and medium-dose irradiation is possible, uniformity is excellent and the load to the scanning equipment is light: hence, this method is superior to the XZ-linear scanning method for most applications. (author)

  6. Automated PET-only quantification of amyloid deposition with adaptive template and empirically pre-defined ROI

    Science.gov (United States)

    Akamatsu, G.; Ikari, Y.; Ohnishi, A.; Nishida, H.; Aita, K.; Sasaki, M.; Yamamoto, Y.; Sasaki, M.; Senda, M.

    2016-08-01

    Amyloid PET is useful for early and/or differential diagnosis of Alzheimer’s disease (AD). Quantification of amyloid deposition using PET has been employed to improve diagnosis and to monitor AD therapy, particularly in research. Although MRI is often used for segmentation of gray matter and for spatial normalization into standard Montreal Neurological Institute (MNI) space where region-of-interest (ROI) template is defined, 3D MRI is not always available in clinical practice. The purpose of this study was to examine the feasibility of PET-only amyloid quantification with an adaptive template and a pre-defined standard ROI template that has been empirically generated from typical cases. A total of 68 subjects who underwent brain 11C-PiB PET were examined. The 11C-PiB images were non-linearly spatially normalized to the standard MNI T1 atlas using the same transformation parameters of MRI-based normalization. The automatic-anatomical-labeling-ROI (AAL-ROI) template was applied to the PET images. All voxel values were normalized by the mean value of cerebellar cortex to generate the SUVR-scaled images. Eleven typical positive images and eight typical negative images were normalized and averaged, respectively, and were used as the positive and negative template. Positive and negative masks which consist of voxels with SUVR  ⩾1.7 were extracted from both templates. Empirical PiB-prone ROI (EPP-ROI) was generated by subtracting the negative mask from the positive mask. The 11C-PiB image of each subject was non-rigidly normalized to the positive and negative template, respectively, and the one with higher cross-correlation was adopted. The EPP-ROI was then inversely transformed to individual PET images. We evaluated differences of SUVR between standard MRI-based method and PET-only method. We additionally evaluated whether the PET-only method would correctly categorize 11C-PiB scans as positive or negative. Significant correlation was observed between the SUVRs

  7. Non-uniformity calibration for MWIR polarization imagery obtained with integrated microgrid polarimeters

    Science.gov (United States)

    Liu, Hai-Zheng; Shi, Ze-Lin; Feng, Bin; Hui, Bin; Zhao, Yao-Hong

    2016-03-01

    Integrating microgrid polarimeters on focal plane array (FPA) of an infrared detector causes non-uniformity of polarization response. In order to reduce the effect of polarization non-uniformity, this paper constructs an experimental setup for capturing raw flat-field images and proposes a procedure for acquiring non-uniform calibration (NUC) matrix and calibrating raw polarization images. The proposed procedure takes the incident radiation as a polarization vector and offers a calibration matrix for each pixel. Both our matrix calibration and two-point calibration are applied to our mid-wavelength infrared (MWIR) polarization imaging system with integrated microgrid polarimeters. Compared with two point calibration, our matrix calibration reduces non-uniformity by 30 40% under condition of flat-field data test with polarization. The ourdoor scene observation experiment indicates that our calibration can effectively reduce polarization non-uniformity and improve the image quality of our MWIR polarization imaging system.

  8. Practical implementation of Channelized Hotelling Observers: Effect of ROI size.

    Science.gov (United States)

    Ferrero, Andrea; Favazza, Christopher P; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia H

    2017-03-01

    Fundamental to the development and application of channelized Hotelling observer (CHO) models is the selection of the region of interest (ROI) to evaluate. For assessment of medical imaging systems, reducing the ROI size can be advantageous. Smaller ROIs enable a greater concentration of interrogable objects in a single phantom image, thereby providing more information from a set of images and reducing the overall image acquisition burden. Additionally, smaller ROIs may promote better assessment of clinical patient images as different patient anatomies present different ROI constraints. To this end, we investigated the minimum ROI size that does not compromise the performance of the CHO model. In this study, we evaluated both simulated images and phantom CT images to identify the minimum ROI size that resulted in an accurate figure of merit (FOM) of the CHO's performance. More specifically, the minimum ROI size was evaluated as a function of the following: number of channels, spatial frequency and number of rotations of the Gabor filters, size and contrast of the object, and magnitude of the image noise. Results demonstrate that a minimum ROI size exists below which the CHO's performance is grossly inaccurate. The minimum ROI size is shown to increase with number of channels and be dictated by truncation of lower frequency filters. We developed a model to estimate the minimum ROI size as a parameterized function of the number of orientations and spatial frequencies of the Gabor filters, providing a guide for investigators to appropriately select parameters for model observer studies.

  9. Transverse Laser Beam Shaping in High Brightness Electron Gun at ATF

    CERN Document Server

    Roychowdhury, S

    2005-01-01

    The brightness of electron beams from a photo injector is influenced by the transverse and longitudinal distribution of the laser beam illuminating the cathode. Previous studies at Brookhaven Accelerator Test Facility have shown that formation of an ideal e-beam with lowest transverse emittance requires uniform circular distribution of the emitted electrons. The use of the uniformly distributed power of the laser beam may not lead to that of the emitted electrons because of the non-uniform quantum efficiency. A proper shaping of the laser beam can compensate for this non-uniformity. In this paper we describe the use of digital light processing (DLP) technique based on digital mirror device (DMD) for spatial modulation of the laser beam, for measurements of the quantum efficiency map, and for creating the desirable e-beam density profiles. A DMD is aμelectronic mechanical system (MEMS) comprising of millions of highly reflectiveμmirrors controlled by underlying electronics. We present exper...

  10. Uniform versus Gaussian Beams: A Comparison of the Effects of Diffraction, Obscuration, and Aberations.

    Science.gov (United States)

    1985-12-16

    balancing is discussed for the two types of beams. Zernike polynomials representing balanced primary aberration for uniform and Gaussian annular beams...plotted on a logarithmic scale (Figs. 3c and 3d ). The positions of maxima and minima and the correspond- ing irradiance and encircled-power values are...aberration 2 4 (representing a term in the expansion of the aberration in terms of a set of " Zernike " polynomials which are orthonormal over the amplitude

  11. Behavior of Uniform Anisotropic Beams of Rectangular Section under Transverse Impact of a Mass

    Directory of Open Access Journals (Sweden)

    Lu Chun

    1997-01-01

    Full Text Available A numerical method is presented to investigate the dynamic response of uniform orthotropic beams subjected to an impact of a mass. Higher order shear deformation and rotary inertia are included in the analysis of the beams. The impactor and laminated composite beam are treated as a system. The nonlinear differential governing equations of motion are then derived based on the Lagrange principle and modified nonlinear contact law, and solved numerically. The solution procedure is applicable to arbitrary boundary conditions. Numerical results are compared with those available in the literature to demonstrate the validity of the method, and very good agreement is achieved. The effects of boundary conditions on the contact force, contact duration, stress distributions, and beam deflection are discussed.

  12. Parallel processing and non-uniform grids in global air quality modeling

    NARCIS (Netherlands)

    Berkvens, P.J.F.; Bochev, Mikhail A.

    2002-01-01

    A large-scale global air quality model, running efficiently on a single vector processor, is enhanced to make more realistic and more long-term simulations feasible. Two strategies are combined: non-uniform grids and parallel processing. The communication through the hierarchy of non-uniform grids

  13. Strain distributions in nano-onions with uniform and non-uniform compositions

    International Nuclear Information System (INIS)

    Duan, H L; Karihaloo, B L; Wang, J; Yi, X

    2006-01-01

    Nano-onions are ellipsoidal or spherical particles consisting of a core surrounded by concentric shells of nanometre size. Nano-onions produced by self-assembly and colloidal techniques have different structures and compositions, and thus differ in the state of strains. The mismatch of the thermal expansion coefficients and lattice constants between neighbouring shells induces stress/strain fields in the core and shells, which in turn affect their physical/mechanical properties and/or the properties of the composites containing them. In this paper, the strains in embedded and free-standing nano-onions with uniform and non-uniform compositions are studied in detail. It is found that the strains in the nano-onions can be modified by adjusting their compositions and structures. The results are useful for the band structure engineering of semiconductor nano-onions

  14. Investigating the use of texture features for analysis of breast lesions on contrast-enhanced cone beam CT

    Science.gov (United States)

    Wang, Xixi; Nagarajan, Mahesh B.; Conover, David; Ning, Ruola; O'Connell, Avice; Wismueller, Axel

    2014-04-01

    Cone beam computed tomography (CBCT) has found use in mammography for imaging the entire breast with sufficient spatial resolution at a radiation dose within the range of that of conventional mammography. Recently, enhancement of lesion tissue through the use of contrast agents has been proposed for cone beam CT. This study investigates whether the use of such contrast agents improves the ability of texture features to differentiate lesion texture from healthy tissue on CBCT in an automated manner. For this purpose, 9 lesions were annotated by an experienced radiologist on both regular and contrast-enhanced CBCT images using two-dimensional (2D) square ROIs. These lesions were then segmented, and each pixel within the lesion ROI was assigned a label - lesion or non-lesion, based on the segmentation mask. On both sets of CBCT images, four three-dimensional (3D) Minkowski Functionals were used to characterize the local topology at each pixel. The resulting feature vectors were then used in a machine learning task involving support vector regression with a linear kernel (SVRlin) to classify each pixel as belonging to the lesion or non-lesion region of the ROI. Classification performance was assessed using the area under the receiver-operating characteristic (ROC) curve (AUC). Minkowski Functionals derived from contrastenhanced CBCT images were found to exhibit significantly better performance at distinguishing between lesion and non-lesion areas within the ROI when compared to those extracted from CBCT images without contrast enhancement (p < 0.05). Thus, contrast enhancement in CBCT can improve the ability of texture features to distinguish lesions from surrounding healthy tissue.

  15. Annotating image ROIs with text descriptions for multimodal biomedical document retrieval

    Science.gov (United States)

    You, Daekeun; Simpson, Matthew; Antani, Sameer; Demner-Fushman, Dina; Thoma, George R.

    2013-01-01

    Regions of interest (ROIs) that are pointed to by overlaid markers (arrows, asterisks, etc.) in biomedical images are expected to contain more important and relevant information than other regions for biomedical article indexing and retrieval. We have developed several algorithms that localize and extract the ROIs by recognizing markers on images. Cropped ROIs then need to be annotated with contents describing them best. In most cases accurate textual descriptions of the ROIs can be found from figure captions, and these need to be combined with image ROIs for annotation. The annotated ROIs can then be used to, for example, train classifiers that separate ROIs into known categories (medical concepts), or to build visual ontologies, for indexing and retrieval of biomedical articles. We propose an algorithm that pairs visual and textual ROIs that are extracted from images and figure captions, respectively. This algorithm based on dynamic time warping (DTW) clusters recognized pointers into groups, each of which contains pointers with identical visual properties (shape, size, color, etc.). Then a rule-based matching algorithm finds the best matching group for each textual ROI mention. Our method yields a precision and recall of 96% and 79%, respectively, when ground truth textual ROI data is used.

  16. Weighted backprojection implemented with a non-uniform attenuation map for improved SPECT quantitation

    International Nuclear Information System (INIS)

    Manglos, S.H.; Jaszczak, R.J.; Floyd, C.E.

    1988-01-01

    A method is developed to improve quantitation in SPECT imaging by using an attenuation compensation method which includes the correct non-uniform attenuation spatial distribution (''map''). The method is based on the technique of weighted back projection, previously developed for uniform attenuation. The method is tested by imaging a non-uniform phantom, reconstructing with the known attenuation map, and quantitatively comparing the resultant image with the known activity distribution. Reconstructed image profiles are dramatically improved in comparison to reconstructions without compensation or with an assumed uniform attenuation map. Contrast measurements further quantify the improvement. Line spread function distortions seen previously in non-uniform geometries are essentially eliminated by the method. Therefore, the method appears to be appropriate for these geometries, if the non-uniform map can be determined. Some additional image distortions introduced by the compensation method are noted and will require further study

  17. Laser beam uniformity and stability using homogenizer-based fiber optic launch method: square core fiber delivery

    Science.gov (United States)

    Lizotte, Todd E.

    2011-03-01

    Over the years, technological achievements within the laser medical diagnostic, treatment, and therapy markets have led to ever increasing requirements for greater control of critical laser beam parameters. Increased laser power/energy stabilization, temporal and spatial beam shaping and flexible laser beam delivery systems with ergonomic focusing or imaging lens systems are sought by leading medical laser system producers. With medical procedures that utilize laser energy, there is a constant emphasis on reducing adverse effects that come about by the laser itself or its optical system, but even when these variables are well controlled the medical professional will still need to deal with the multivariate nature of the human body. Focusing on the variables that can be controlled, such as accurate placement of the laser beam where it will expose a surface being treated as well as laser beam shape and uniformity is critical to minimizing adverse conditions. This paper covers the use of fiber optic beam delivery as a means of defining the beam shape (intensity/power distribution uniformity) at the target plane as well as the use of fiber delivery as a means to allow more flexible articulation of the laser beam over the surface being treated. The paper will present a new concept of using a square core fiber beam delivery design utilizing a unique micro lens array (MLA) launch method that improves the overall stability of the system, by minimizing the impact of the laser instability. The resulting performance of the prototype is presented to demonstrate its stability in comparison to simple lens launch techniques, with an emphasis on homogenization and articulated fiber delivery.

  18. Non-Linear Beam Transport System for the LENS 7 MeV Proton Beam

    CERN Document Server

    Jones, William P; Derenchuk, Vladimir Peter; Rinckel, Thomas; Solberg, Keith

    2005-01-01

    A beam transport system has been designed to carry a high-intensity low-emittance proton beam from the exit of the RFQ-DTL acceleration system of the Indiana University Low Energy Neutron System (LENS)* to the neutron production target. The goal of the design was to provide a beam of uniform density over a 3cm by 3cm area at the target. Two octupole magnets** are employed in the beam line to provide the necessary beam phase space manipulations to achieve this goal. First order calculations were done using TRANSPORT and second order calculations have been performed using TURTLE. Second order simulations have been done using both a Gaussian beam distribution and a particle set generated by calculations of beam transport through the RFQ-DTL using PARMILA. Comparison of the design characteristics with initial measurements from the LENS commissioning process will be made.

  19. An improved non-uniformity correction algorithm and its GPU parallel implementation

    Science.gov (United States)

    Cheng, Kuanhong; Zhou, Huixin; Qin, Hanlin; Zhao, Dong; Qian, Kun; Rong, Shenghui

    2018-05-01

    The performance of SLP-THP based non-uniformity correction algorithm is seriously affected by the result of SLP filter, which always leads to image blurring and ghosting artifacts. To address this problem, an improved SLP-THP based non-uniformity correction method with curvature constraint was proposed. Here we put forward a new way to estimate spatial low frequency component. First, the details and contours of input image were obtained respectively by minimizing local Gaussian curvature and mean curvature of image surface. Then, the guided filter was utilized to combine these two parts together to get the estimate of spatial low frequency component. Finally, we brought this SLP component into SLP-THP method to achieve non-uniformity correction. The performance of proposed algorithm was verified by several real and simulated infrared image sequences. The experimental results indicated that the proposed algorithm can reduce the non-uniformity without detail losing. After that, a GPU based parallel implementation that runs 150 times faster than CPU was presented, which showed the proposed algorithm has great potential for real time application.

  20. The magnetostriction in a superconductor-magnet system under non-uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xueyi; Jiang, Lang; Wu, Hao [Key Laboratory of Mechanics on Disaster and Environment in Western China attached to the Ministry of Education of China, Lanzhou University, Lanzhou, Gansu 730000 (China); Gao, Zhiwen, E-mail: gaozhw@lzu.edu.cn [Department of Mechanics and Engineering Science, College of Civil Engineering and Mechanics, Lanzhou University, Lanzhou, Gansu 730000 (China)

    2017-03-15

    Highlights: • We studied firstly magnetostriction in HTS under non-uniform magnetic field. • The superconductors may be homogeneous and nonhomogeneous. • The magnetostrictions response of the HTS is sensitive to the critical current density and amplitude of the applied magnetic field. • The magnetostriction of nonhomogeneous HTS is larger than that of homogeneous HTS. - Abstract: This paper describes a numerical model to examine the magnetostriction of bulk high-temperature superconductor (HTS) under non-uniform magnetic field in conjunction with finite element analysis. Through this model, the magnetostriction of homogeneous and nonhomogeneous HTS can be implemented under non-uniform magnetic field. Further, the effects of critical current density, applied field frequency and amplitude are also considered. The computational study can provide a fundamental mechanistic understanding the effects of non-uniform magnetic field on magnetostriction of HTS.

  1. Estimating the Accuracy of the Return on Investment (ROI Performance Evaluations

    Directory of Open Access Journals (Sweden)

    Alexei Botchkarev

    2015-12-01

    Full Text Available Return on Investment (ROI is one of the most popular performance measurement and evaluation metrics. ROI analysis (when applied correctly is a powerful tool in comparing solutions and making informed decisions on the acquisitions of information systems. The purpose of this study is to provide a systematic research of the accuracy of the ROI evaluations in the context of information systems implementations. Measurements theory and error analysis, specifically propagation of uncertainties methods, were used to derive analytical expressions for ROI errors. Monte Carlo simulation methodology was used to design and deliver a quantitative experiment to model costs and returns estimating errors and calculate ROI accuracies. Spreadsheet simulation (Microsoft Excel spreadsheets enhanced with Visual Basic for Applications was used to implement Monte Carlo simulations. The main contribution of the study is that this is the first systematic effort to evaluate ROI accuracy. Analytical expressions have been derived for estimating errors of the ROI evaluations. Results of the Monte Carlo simulation will help practitioners in making informed decisions based on explicitly stated factors influencing the ROI uncertainties.

  2. Non-uniform versus uniform attenuation correction in brain perfusion SPET of healthy volunteers

    International Nuclear Information System (INIS)

    Van Laere, K.; Versijpt, J.; Dierckx, R.; Koole, M.

    2001-01-01

    Although non-uniform attenuation correction (NUAC) can supply more accurate absolute quantification, it is not entirely clear whether NUAC provides clear-cut benefits in the routine clinical practice of brain SPET imaging. The aim of this study was to compare the effect of NUAC versus uniform attenuation correction (UAC) on volume of interest (VOI)-based semi-quantification of a large age- and gender-stratified brain perfusion normal database. Eighty-nine healthy volunteers (46 females and 43 males, aged 20-81 years) underwent standardised high-resolution single-photon emission tomography (SPET) with 925 MBq 99m Tc-ethyl cysteinate dimer (ECD) on a Toshiba GCA-9300A camera with 153 Gd or 99m Tc transmission CT scanning. Emission images were reconstructed by filtered back-projection and scatter corrected using the triple-energy window correction method. Both non-uniform Chang attenuation correction (one iteration) and uniform Sorenson correction (attenuation coefficient 0.09 cm -1 ) were applied. Images were automatically re-oriented to a stereotactic template on which 35 predefined VOIs were defined for semi-quantification (normalisation on total VOI counts). Small but significant differences between relative VOI uptake values for NUAC versus UAC in the infratentorial region were found. VOI standard deviations were significantly smaller for UAC, 4.5% (range 2.6-7.5), than for NUAC, 5.0% (2.3-9.0) (P 99m Tc-ECD uptake values in healthy volunteers to those obtained with NUAC, although values for the infratentorial region are slightly lower. NUAC produces a slight increase in inter-subject variability. Further study is necessary in various patient populations to establish the full clinical impact of NUAC in brain perfusion SPET. (orig.)

  3. The use of non-uniform drowning terminology: a follow-up study.

    Science.gov (United States)

    Schmidt, Andrew C; Sempsrott, Justin R; Szpilman, David; Queiroga, Ana Catarina; Davison, Matt S; Zeigler, Ryan J; McAlister, Sean J

    2017-07-17

    In 2002, the World Congress on Drowning developed a uniform definition for drowning. The aim of this study is to determine the prevalence of "non-uniform drowning terminology" (NUDT) and "non-uniform drowning definitions" (NUDD) in peer-reviewed scientific literature from 2010 to 2016, and compare these findings with those from our unpublished study performing a similar analysis on literature from 2003 to 2010. A systematic review was performed using drowning-specific search terms in Pubmed and Web of Science. Titles and abstracts published between July 2010 and January 2016 were screened for relevance to the study focus. Articles meeting screening criteria were reviewed for exclusion criteria to produce the final group of studies. These articles were reviewed by four reviewers for NUDT and NUDD. The Fisher exact test was used to determine any statistically significant changes. The final group of studies included 167 articles. A total of 53 articles (32%) utilized NUDT, with 100% of these including the term "near drowning". The proportion of articles utilizing NUDT was significantly less than reported by our previous study (p drowning (uniform or non-uniform), with 15% of these utilizing NUDD. Our study reveals a statistically significant improvement over the past thirteen years in the use of uniform drowning terminology in peer-reviewed scientific literature, although year-to-year variability over the current study period does not yield an obvious trend. Of the articles reviewed during the 2010-2016 study period, 32% included outdated and non-uniform drowning terminology and definitions. While this reveals an absolute decrease of 11% as compared with the previous study period (2003-2010), there is still significant room for improvement.

  4. Instruction sequences and non-uniform complexity theory

    NARCIS (Netherlands)

    Bergstra, J.A.; Middelburg, C.A.

    2008-01-01

    We develop theory concerning non-uniform complexity in a setting in which the notion of single-pass instruction sequence considered in program algebra is the central notion. We define counterparts of the complexity classes P/poly and NP/poly and formulate a counterpart of the complexity theoretic

  5. Simulating non-Kolmogorov turbulence phase screens based on equivalent structure constant and its influence on simulations of beam propagation

    Directory of Open Access Journals (Sweden)

    Ming Chen

    Full Text Available Gaussian distribution is used to describe the power law along the propagation path and phase screen of the non-Kolmogorov turbulence is proposed based on the equivalent refractive-index structure constants. Various simulations of Gaussian beam propagation in Kolmogorov and non-Kolmogorov turbulence are used for telling the difference between isotropic and anisotropic turbulence. The results imply that the non-Kolmogorov turbulence makes a great influence on the simulations via power law in spectrum and the number of phase screens. Furthermore, the influence is mainly reflected in light intensity and beam drift. Statistics suggest that when Gaussian beam propagate through single phase screen of non-Kolmogorov, maximum and uniformity of light intensity increase first and then decrease with power law, and beam drift firstly increases and then to stabilize. When Gaussian beam propagate through multiple phase screens, relative errors of beam drift decrease with the number of phase screens. And scintillation indices in non-Kolmogorov turbulence is larger than that in Kolmogorov turbulence when the number is small. When the number is big, the scintillation indices in non-Kolmogorov turbulence is smaller than that in Kolmogorov turbulence. The results shown in this paper demonstrate the effect of the non-Kolmogorov turbulence on laser atmospheric transmissions. Thus, this paper suggests a possible direction of the improvement of the laser transmission accuracy over a long distance through the atmosphere.

  6. The prediction of burnout in non-uniformly heated rod clusters from burnout data for uniformly heated round tubes

    International Nuclear Information System (INIS)

    Barnett, P.G.

    1964-11-01

    The practice of using burnout data for uniformly heated round tubes to predict burnout in non-uniformly heated reactor channels having complex cross sections is examined. At least two hypotheses are involved: (i) a relationship exists between uniform and non-uniform heat flux distributions and (ii) a relationship exists between simple and complex channel cross sections. Use of two such hypotheses each accurate to ± 15% and a correlation of uniformly heated round tube data having an R.M.S. error of 5%, could yield errors of ± 40% in any predicted value; this figure of ± 40% is regarded as a realistic upper limit for design purposes. It is shown that no method can exist for relating different channel cross sections to within ± 15% and existing methods for relating different heat flux distributions incur some errors exceeding 20%. Furthermore, any suggested method for relating different heat flux distributions can be adequately checked only when a sufficiently large number of results are available and then the preferable alternative of correlating the data is possible. It is concluded that no reliable method can exist for predicting burnout in rod bundles from uniformly heated round tube data with sufficient accuracy for design purposes. (author)

  7. Random noise attenuation of non-uniformly sampled 3D seismic data along two spatial coordinates using non-equispaced curvelet transform

    Science.gov (United States)

    Zhang, Hua; Yang, Hui; Li, Hongxing; Huang, Guangnan; Ding, Zheyi

    2018-04-01

    The attenuation of random noise is important for improving the signal to noise ratio (SNR). However, the precondition for most conventional denoising methods is that the noisy data must be sampled on a uniform grid, making the conventional methods unsuitable for non-uniformly sampled data. In this paper, a denoising method capable of regularizing the noisy data from a non-uniform grid to a specified uniform grid is proposed. Firstly, the denoising method is performed for every time slice extracted from the 3D noisy data along the source and receiver directions, then the 2D non-equispaced fast Fourier transform (NFFT) is introduced in the conventional fast discrete curvelet transform (FDCT). The non-equispaced fast discrete curvelet transform (NFDCT) can be achieved based on the regularized inversion of an operator that links the uniformly sampled curvelet coefficients to the non-uniformly sampled noisy data. The uniform curvelet coefficients can be calculated by using the inversion algorithm of the spectral projected-gradient for ℓ1-norm problems. Then local threshold factors are chosen for the uniform curvelet coefficients for each decomposition scale, and effective curvelet coefficients are obtained respectively for each scale. Finally, the conventional inverse FDCT is applied to the effective curvelet coefficients. This completes the proposed 3D denoising method using the non-equispaced curvelet transform in the source-receiver domain. The examples for synthetic data and real data reveal the effectiveness of the proposed approach in applications to noise attenuation for non-uniformly sampled data compared with the conventional FDCT method and wavelet transformation.

  8. Non-coplanar automatic beam orientation selection in cranial IMRT: a practical methodology

    Energy Technology Data Exchange (ETDEWEB)

    Llacer, Jorge [EC Engineering Consultants LLC, 130 Forest Hill Drive, Los Gatos, CA 95032 (United States); Li Sicong [Department of Radiation Oncology, University of Nebraska Medical Center, Omaha, NE 68198 (United States); Agazaryan, Nzhde; Solberg, Timothy D [Department of Radiation Oncology, University of California, Los Angeles, CA 90095 (United States); Promberger, Claus [BrainLAB AG, Kapellenstrasse 12, 85622 Feldkirchen (Germany)], E-mail: escalivat@jllacer.com, E-mail: sl1@unmc.edu, E-mail: NAgazaryan@mednet.ucla.edu, E-mail: claus.promberger@brainlab.com, E-mail: Timothy.Solberg@utsouthwestern.edu

    2009-03-07

    This paper proposes a method for automatic selection of beam orientations in non-coplanar cranial IMRT. Methods of computer vision, beam's eye view techniques and neural networks are used to define a new geometry-based methodology that leads to treatment plans for cranial lesions that are comparable in quality to those generated by experienced radiation physicists. The automatic beam selection (ABS) process can be carried out in clinically useful computation times, in 1 min or less for most cases. In the process of describing the ABS process, it is shown that the cranial beam orientation optimization problem is mathematically ill posed, with the expectation that a large number of solutions will lead to similar results. Nevertheless, there are better and worse solutions and we show that the proposed ABS process, by its design, has to lead to one of the better ones. We have carried out extensive tests with 14 patients with beam selection tasks ranging from the rather simple to quite complex. The ABS process has always yielded optimizations with results that are considered good for clinic use. Seven-beam coplanar optimizations for some of the patients have also been investigated. Comparisons with non-coplanar optimizations indicate in which cases the simpler coplanar plans can be used to advantage. Parameters used in the comparisons are dose-volume histograms, minimum and maximum PTV doses, equivalent uniform doses for the PTV and OARs, and treatment volume, conformity and normal tissue indices. It is felt that the current ABS methodology is ready for extensive clinical tests.

  9. A DSP-based neural network non-uniformity correction algorithm for IRFPA

    Science.gov (United States)

    Liu, Chong-liang; Jin, Wei-qi; Cao, Yang; Liu, Xiu

    2009-07-01

    An effective neural network non-uniformity correction (NUC) algorithm based on DSP is proposed in this paper. The non-uniform response in infrared focal plane array (IRFPA) detectors produces corrupted images with a fixed-pattern noise(FPN).We introduced and analyzed the artificial neural network scene-based non-uniformity correction (SBNUC) algorithm. A design of DSP-based NUC development platform for IRFPA is described. The DSP hardware platform designed is of low power consumption, with 32-bit fixed point DSP TMS320DM643 as the kernel processor. The dependability and expansibility of the software have been improved by DSP/BIOS real-time operating system and Reference Framework 5. In order to realize real-time performance, the calibration parameters update is set at a lower task priority then video input and output in DSP/BIOS. In this way, calibration parameters updating will not affect video streams. The work flow of the system and the strategy of real-time realization are introduced. Experiments on real infrared imaging sequences demonstrate that this algorithm requires only a few frames to obtain high quality corrections. It is computationally efficient and suitable for all kinds of non-uniformity.

  10. Characterization and Processing of Non-Uniformities in Back-Illuminated CCDs

    Science.gov (United States)

    Lemm, Alia D.; Della-Rose, Devin J.; Maddocks, Sally

    2018-01-01

    In astronomical photometry, Charged Coupled Device (CCD) detectors are used to achieve high precision photometry and must be properly calibrated to correct for noise and pixel non-uniformities. Uncalibrated images may contain bias offset, dark current, bias structure and uneven illumination. In addition, standard data reduction is often not sufficient to “normalize” imagery to single-digit millimagnitude (mmag) precision. We are investigating an apparent non-uniformity, or interference pattern, in a back-illuminated sensor, the Alta U-47, attached to a DFM Engineering 41-cm Ritchey-Chrétien f/8 telescope. Based on the amplitude of this effect, we estimate that instrument magnitude peak-to-valley deviations of 50 mmag or more may result. Our initial testing strongly suggests that reflected skylight from high pressure sodium city lights may be the cause of this interference pattern. Our research goals are twofold: to fully characterize this non-uniformity and to determine the best method to remove this interference pattern from our reduced CCD images.

  11. Biopsy Needle Localization and Tracking Using ROI-RK Method

    Directory of Open Access Journals (Sweden)

    Yue Zhao

    2014-01-01

    Full Text Available ROI-RK method is a biopsy needle localization and tracking method. Previous research work has proved that it has a robust performance on different series of simulated 3D US volumes. Unfortunately, in real situations, because of the strong speckle noise of the ultrasound image and the different echogenic properties of the tissues, the real 3D US volumes have more complex background than the simulated images used previously. In this paper, to adapt the ROI-RK method in real 3D US volumes, a line-filter enhancement calculation only in the ROI is added to increase the contrast between the needle and background tissue, decreasing the phenomenon of expansion of the biopsy needle due to reverberation of ultrasound in the needle. To make the ROI-RK method more stable, a self-correction system is also implemented. Real data have been acquired on an ex vivo heart of lamb. The result of the ROI-RK method shows that it is capable to localize and track the biopsy needle in real situations, and it satisfies the demand of real-time application.

  12. The Pierce diode with an external circuit: II, Non-uniform equilibria

    International Nuclear Information System (INIS)

    Lawson, W.S.

    1987-01-01

    The non-uniform (non-linear) equilibria of the classical (short circuit) Pierce diode and the extended (series RLC external circuit) Pierce diode are described theoretically, and explored via computer simulation. It is found that most equilibria are correctly predicted by theory, but that the continuous set of equilibria of the classical Pierce diode at α = 2π are not observed. The stability characteristics of the non-uniform equilibria are also worked out, and are consistent with the simulations. 8 refs., 22 figs., 3 tabs

  13. Performance of shear-wave elastography for breast masses using different region-of-interest (ROI) settings.

    Science.gov (United States)

    Youk, Ji Hyun; Son, Eun Ju; Han, Kyunghwa; Gweon, Hye Mi; Kim, Jeong-Ah

    2018-07-01

    Background Various size and shape of region of interest (ROI) can be applied for shear-wave elastography (SWE). Purpose To investigate the diagnostic performance of SWE according to ROI settings for breast masses. Material and Methods To measure elasticity for 142 lesions, ROIs were set as follows: circular ROIs 1 mm (ROI-1), 2 mm (ROI-2), and 3 mm (ROI-3) in diameter placed over the stiffest part of the mass; freehand ROIs drawn by tracing the border of mass (ROI-M) and the area of peritumoral increased stiffness (ROI-MR); and circular ROIs placed within the mass (ROI-C) and to encompass the area of peritumoral increased stiffness (ROI-CR). Mean (E mean ), maximum (E max ), and standard deviation (E SD ) of elasticity values and their areas under the receiver operating characteristic (ROC) curve (AUCs) for diagnostic performance were compared. Results Means of E mean and E SD significantly differed between ROI-1, ROI-2, and ROI-3 ( P Shear-wave elasticity values and their diagnostic performance vary based on ROI settings and elasticity indices. E max is recommended for the ROIs over the stiffest part of mass and an ROI encompassing the peritumoral area of increased stiffness is recommended for elastic heterogeneity of mass.

  14. A dynamic model of gas flow in a non-uniform pipe

    International Nuclear Information System (INIS)

    Mensah, S.; Lepp, R.M.

    1979-08-01

    A gas-line model, based on the analysis of compressible flow with friction, has been developed to describe the dynamics of gas flow in a non-uniform line, i.e. one comprising segments of different lengths and diameters. Acoustic wave analysis was used in a novel way, by considering the line as a cascaded connection of uniform pipes separated by discontinuities. The transmission matrix representing this non-uniform line is the product of the matrices for each element in the system. To facilitate implementation of the theoretical model on a hybrid computer, modal approximatons to its transfer functions were derived. Both models were validated against experimental data. (author)

  15. Multi-resolution analysis for region of interest extraction in thermographic nondestructive evaluation

    Science.gov (United States)

    Ortiz-Jaramillo, B.; Fandiño Toro, H. A.; Benitez-Restrepo, H. D.; Orjuela-Vargas, S. A.; Castellanos-Domínguez, G.; Philips, W.

    2012-03-01

    Infrared Non-Destructive Testing (INDT) is known as an effective and rapid method for nondestructive inspection. It can detect a broad range of near-surface structuring flaws in metallic and composite components. Those flaws are modeled as a smooth contour centered at peaks of stored thermal energy, termed Regions of Interest (ROI). Dedicated methodologies must detect the presence of those ROIs. In this paper, we present a methodology for ROI extraction in INDT tasks. The methodology deals with the difficulties due to the non-uniform heating. The non-uniform heating affects low spatial/frequencies and hinders the detection of relevant points in the image. In this paper, a methodology for ROI extraction in INDT using multi-resolution analysis is proposed, which is robust to ROI low contrast and non-uniform heating. The former methodology includes local correlation, Gaussian scale analysis and local edge detection. In this methodology local correlation between image and Gaussian window provides interest points related to ROIs. We use a Gaussian window because thermal behavior is well modeled by Gaussian smooth contours. Also, the Gaussian scale is used to analyze details in the image using multi-resolution analysis avoiding low contrast, non-uniform heating and selection of the Gaussian window size. Finally, local edge detection is used to provide a good estimation of the boundaries in the ROI. Thus, we provide a methodology for ROI extraction based on multi-resolution analysis that is better or equal compared with the other dedicate algorithms proposed in the state of art.

  16. Non-uniformity measurements of PbWO4 crystals

    International Nuclear Information System (INIS)

    Depasse, P.; Ernenwein, J.P.; Ille, B.; Martin, F.; Rosset, C.; Zach, F.

    1998-11-01

    Two independent methods have been used to measure the longitudinal non-uniformity scintillation response of 3 different (23-cm long) PbWO 4 crystals. The first one is the classical 60 Co source method. The source is collimated along the crystal, each 1,5-cm, and the scintillation signal is measured with a photomultiplier (a hybrid photomultiplier in our case). The second one is the use of cosmic particles (Minimum Ionizing Particles). A cosmic bench allows reconstructing the track of the MIP's and thus the energy deposit with the help of a full GEANT simulation of the setup. Variations of E along the crystal artificially cut in 1,5-cm divisions, leads to determine the non-uniformity. The conclusion is that both methods agree quite well. Furthermore, a good estimation of crystal light yield can be obtained. (author)

  17. Robust finger vein ROI localization based on flexible segmentation.

    Science.gov (United States)

    Lu, Yu; Xie, Shan Juan; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2013-10-24

    Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system.

  18. Robust Finger Vein ROI Localization Based on Flexible Segmentation

    Directory of Open Access Journals (Sweden)

    Dong Sun Park

    2013-10-01

    Full Text Available Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system.

  19. Robust Finger Vein ROI Localization Based on Flexible Segmentation

    Science.gov (United States)

    Lu, Yu; Xie, Shan Juan; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2013-01-01

    Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system. PMID:24284769

  20. Sharp lower bounds on the extractable randomness from non-uniform sources

    NARCIS (Netherlands)

    Skoric, B.; Obi, C.; Verbitskiy, E.A.; Schoenmakers, B.

    2011-01-01

    Extraction of uniform randomness from (noisy) non-uniform sources is an important primitive in many security applications, e.g. (pseudo-)random number generators, privacy-preserving biometrics, and key storage based on Physical Unclonable Functions. Generic extraction methods exist, using universal

  1. Maximum Power Point tracking algorithm based on I-V characteristic of PV array under uniform and non-uniform conditions

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Iman-Eini, H.; Asaei, B.

    2012-01-01

    This paper presents a new algorithm based on characteristic equation of solar cells to determine the Maximum Power Point (MPP) of PV modules under partially shaded conditions (PSC). To achieve this goal, an analytic condition is introduced to determine uniform or non-uniform atmospheric condition...

  2. Investigation of Non-Uniform Rust Distribution and Its Effects on Corrosion Induced Cracking in Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Sutrisno Wahyuniarsih

    2017-01-01

    Full Text Available Uniform corrosion still widely used by a lot of researchers and engineers to analyze the corrosion induced cracking. However, in practice, corrosion process occurred non-uniformly. The part nearest to the exposed surface is more likely to have faster corrosion initiation compared with other regions. This research is mainly focused on investigating the effect of non-uniform rust distribution to cover cracking in reinforced concrete. An experimental test performed using accelerated corrosion test by using 5% NaCl solution and applied a constant electric current to the concrete samples. The rust distribution and measurement were observed by using a digital microscope. Based on the experimental result, it was found that the rust was distributed in a non-uniform pattern. As a result, the cracks also formed non-uniformly along the perimeter of steel bar. At the last part of this paper, a simulation result of concrete cracking induced by non-uniform corrosion is presented. The result compared with a simulation using uniform corrosion assumption to investigate the damage pattern of each model. The simulation result reveals stress evolution due to rust expansion which leads to concrete cracking. Furthermore, a comparison of stresses induced by non-uniform corrosion and uniform corrosion indicates that non-uniform corrosion could lead to earlier damage to the structure which is specified by the formation and propagation of the crack.

  3. Filtered region of interest cone-beam rotational angiography

    International Nuclear Information System (INIS)

    Schafer, Sebastian; Noeel, Peter B.; Walczak, Alan M.; Hoffmann, Kenneth R.

    2010-01-01

    Purpose: Cone-beam rotational angiography (CBRA) is widely used in the modern clinical settings. In a number of procedures, the area of interest is often considerably smaller than the field of view (FOV) of the detector, subjecting the patient to potentially unnecessary x-ray dose. The authors therefore propose a filter-based method to reduce the dose in the regions of low interest, while supplying high image quality in the region of interest (ROI). Methods: For such procedures, the authors propose a method of filtered region of interest (FROI)-CBRA. In the authors' approach, a gadolinium filter with a circular central opening is placed into the x-ray beam during image acquisition. The central region is imaged with high contrast, while peripheral regions are subjected to a substantial lower intensity and dose through beam filtering. The resulting images contain a high contrast/intensity ROI, as well as a low contrast/intensity peripheral region, and a transition region in between. To equalize the two regions' intensities, the first projection of the acquisition is performed with and without the filter in place. The equalization relationship, based on Beer's law, is established through linear regression using corresponding filtered and nonfiltered data. The transition region is equalized based on radial profiles. Results: Evaluations in 2D and 3D show no visible difference between conventional FROI-CBRA projection images and reconstructions in the ROI. CNR evaluations show similar image quality in the ROI, with a reduced CNR in the reconstructed peripheral region. In all filtered projection images, the scatter fraction inside the ROI was reduced. Theoretical and experimental dose evaluations show a considerable dose reduction; using a ROI half the original FOV reduces the dose by 60% for the filter thickness of 1.29 mm. Conclusions: These results indicate the potential of FROI-CBRA to reduce the dose to the patient while supplying the physician with the desired

  4. Filtered region of interest cone-beam rotational angiography

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, Sebastian; Noeel, Peter B.; Walczak, Alan M.; Hoffmann, Kenneth R. [Department of Mechanical Engineering, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States) and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Computer Science, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States) and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Mechanical Engineering, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Computer Science, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States) and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States)

    2010-02-15

    Purpose: Cone-beam rotational angiography (CBRA) is widely used in the modern clinical settings. In a number of procedures, the area of interest is often considerably smaller than the field of view (FOV) of the detector, subjecting the patient to potentially unnecessary x-ray dose. The authors therefore propose a filter-based method to reduce the dose in the regions of low interest, while supplying high image quality in the region of interest (ROI). Methods: For such procedures, the authors propose a method of filtered region of interest (FROI)-CBRA. In the authors' approach, a gadolinium filter with a circular central opening is placed into the x-ray beam during image acquisition. The central region is imaged with high contrast, while peripheral regions are subjected to a substantial lower intensity and dose through beam filtering. The resulting images contain a high contrast/intensity ROI, as well as a low contrast/intensity peripheral region, and a transition region in between. To equalize the two regions' intensities, the first projection of the acquisition is performed with and without the filter in place. The equalization relationship, based on Beer's law, is established through linear regression using corresponding filtered and nonfiltered data. The transition region is equalized based on radial profiles. Results: Evaluations in 2D and 3D show no visible difference between conventional FROI-CBRA projection images and reconstructions in the ROI. CNR evaluations show similar image quality in the ROI, with a reduced CNR in the reconstructed peripheral region. In all filtered projection images, the scatter fraction inside the ROI was reduced. Theoretical and experimental dose evaluations show a considerable dose reduction; using a ROI half the original FOV reduces the dose by 60% for the filter thickness of 1.29 mm. Conclusions: These results indicate the potential of FROI-CBRA to reduce the dose to the patient while supplying the physician with

  5. Ludwig, un roi sur la lune : l’histoire d’un roi fou jouée par des comédien.ne.s en situation de handicap mental

    Directory of Open Access Journals (Sweden)

    Marie Astier

    2017-12-01

    Full Text Available Ludwig, un roi sur la lune, spectacle mis en scène par Madeleine Louarn avec les comédien.ne.s professionnels en situation de handicap mental de l’Atelier Catalyse et présenté lors de la dernière édition du Festival d’Avignon n’est pas une reconstitution historique de la vie de Louis II de Bavière, roi du XIXe siècle diagnostiqué paranoïaque et destitué pour être interné, mais une tentative de transcrire théâtralement la perception du monde d’un homme amoureux de l’Art, de la nature et des hommes, mais qui devait être Roi. Ce n’est ni un personnage ni des comédien.ne.s « handicapé.e.s » que nous sommes invités à voir, mais les visions de Ludwig incarnées par des comédien.ne.s qui se trouvent être en situation de handicap mental. Dans ce spectacle, la « folie » devenue plus tard « handicap mental » apparaît sous les traits de la non-conformité bien plus que sous ceux de la pathologie.

  6. Developments in non-destructive beam diagnostics

    International Nuclear Information System (INIS)

    Fraser, J.S.

    1981-01-01

    With the large average beam currents being achieved in accelerators and storage rings, there is an increasing need for non-destructive beam diagnostic devices. For continuous beams, position monitors of the capacitive pick-up type are replaced by resonant devices that respond to the transverse displacement of the beam centroid. Bunch length monitors of the SLAC type using resonant cavities operating in the TM 010 mode can be used for continuous beams. The more detailed information derivable from beam profile scanners requires development of improved non-destructive devices. Profile monitors which scan the visible light produced by high current beams may be more reliable than ones using the residual ionization if the light intensity from gas molecules following nonionizing collisions with beam particles gives a measure of the beam current density independent of the local electron density. The intense Balmer series lines from neutral hydrogen beams have been used successfully to measure beam profiles. At CRNL and at LASL, beam light profile monitors are being developed for high average current accelerators. Three or more projections will be recorded to allow tomographic reconstruction of the two-dimensional beam current density. Light detection is either by intensified Reticons or ISIT vidicons. The use of three or more beam light monitors on a beam transport line will also permit estimates of the transverse emittance to be made through the reconstruction technique

  7. A comparison on the heat load of HTS current leads with respect to uniform and non-uniform cross-sectional areas

    Energy Technology Data Exchange (ETDEWEB)

    Han, Seung Hak; Nam, Seok Ho; Lee, Je Yull; Song, Seung Hyun; Jeon, Hae Ryong; Baek, Geon Woo; Ko, Tae Kuk [Yonsei University, Seoul (Korea, Republic of); Kang, Hyoung Ku [Korea National University of Transportation, Chungju (Korea, Republic of)

    2017-09-15

    Current lead is a device that connects the power supply and superconducting magnets. High temperature superconductor (HTS) has lower thermal conductivity and higher current density than normal metal. For these reasons, the heat load can be reduced by replacing the normal metal of the current lead with the HTS. Conventional HTS current lead has same cross-sectional area in the axial direction. However, this is over-designed at the cold-end (4.2 K) in terms of current. The heat load can be reduced by reducing this part because the heat load is proportional to the cross-sectional area. Therefore, in this paper, heat load was calculated from the heat diffusion equation of HTS current leads with uniform and non-uniform cross-sectional areas. The cross-sectional area of the warm-end (65K) is designed considering burnout time when cooling system failure occurs. In cold-end, Joule heat and heat load due to current conduction occurs at the same time, so the cross-sectional area where the sum of the two heat is minimum is obtained. As a result of simulation, current leads for KSTAR TF coils with uniform and non-uniform cross-sectional areas were designed, and it was confirmed that the non-uniform cross-sectional areas could further reduce the heat load.

  8. Non-Uniform Dose Mapping Controlled by Modulated Vertical and Horizontal Scans

    International Nuclear Information System (INIS)

    Ninomiya, S.; Kimura, Y.; Kudo, T.; Ochi, A.; Toda, R.; Tsukihara, M.; Sato, F.; Fuse, G.; Ueno, K.; Sugitani, M.

    2008-01-01

    Since geometries of semi-conductor devices continue to shrink, the requirement for each process becomes severer to keep uniformity of electrical parameters of the semi-conductor devices. A larger wafer also causes larger variations. Thus it has been strongly required for ion implantation process to compensate for the variations from other processes because of its good dose controllability. A newly developed mapping of intentional non-uniform dosage system, which is named 'MIND system', is implemented in SEN's single-wafer-type implanters. The MIND system controls both horizontal and vertical scan speed simultaneously. Intentional two-dimensional non-uniform profiles of sheet resistance, such as concentric and eccentric profiles, are obtained only by single-step ion implantation.

  9. Non-similar solutions for unsteady flow over a yawed cylinder with non-uniform mass transfer through a slot

    Directory of Open Access Journals (Sweden)

    G. Revathi

    2014-12-01

    Full Text Available Non-similar solutions are found numerically to a system of coupled non-linear partial differential equations indicating, unsteady laminar water boundary layer flow over yawed cylinder using implicit finite difference scheme along with Quasi-linearization technique. The fluid properties such as viscosity and Prandtl number are considered as an inverse function of temperature. Unsteadiness is caused by upstream velocity in and directions and non-uniform mass transfer (suction/injection which is applied through slot on the surface of the geometry. The effect of yaw angle, variable fluid properties and non-uniform mass transfer on skin friction and heat transfer coefficients is analyzed. It is found that non-uniform slot suction and downstream movement of the slot cause the point of vanishing skin friction moves downstream, but non-uniform slot injection produces the opposite result of that corresponding to the suction case. When the yaw angle increases, both the skin friction coefficient in the – direction and the heat transfer coefficient decrease but the skin friction coefficient in the – direction increases for all times. The effect of the yaw angle is very little on the point of vanishing skin friction.

  10. TDM/FM/FDMA - A modulation technique for multiple-beam satellites which precludes cochannel interference and allows non-uniform geographic distribution of user channels

    Science.gov (United States)

    Springett, J. C.

    1982-01-01

    The technique outlined in this paper is intended to eliminate the problems of cochannel interference and uniform geographic distribution of user channels which arise in conventional designs for a multiple spot beam communication satellite to serve mobile telephony users across the CONUS. By time multiplexing FM/FDMA signal ensembles so that only those beams operating on distinct frequency subbands are allowed to transmit concurrently, cochannel interference arising from simultaneous frequency subband reuse is precluded. Thus, time disjoint frequency reuse is accomplished over a repetitive sequence of fixed time slots. By assigning different size subbands to each time slot, a market of nonuniform users can be accommodated. The technique results in a greatly simplified antenna feed system design for the satellite, at a cost of imposing the need for time slot synchronization on the mobile FM receivers whose ability for rejecting adjacent channel interference is somewhat diminished.

  11. TDM/FM/FDMA - A modulation technique for multiple-beam satellites which precludes cochannel interference and allows non-uniform geographic distribution of user channels

    Science.gov (United States)

    Springett, J. C.

    The technique outlined in this paper is intended to eliminate the problems of cochannel interference and uniform geographic distribution of user channels which arise in conventional designs for a multiple spot beam communication satellite to serve mobile telephony users across the CONUS. By time multiplexing FM/FDMA signal ensembles so that only those beams operating on distinct frequency subbands are allowed to transmit concurrently, cochannel interference arising from simultaneous frequency subband reuse is precluded. Thus, time disjoint frequency reuse is accomplished over a repetitive sequence of fixed time slots. By assigning different size subbands to each time slot, a market of nonuniform users can be accommodated. The technique results in a greatly simplified antenna feed system design for the satellite, at a cost of imposing the need for time slot synchronization on the mobile FM receivers whose ability for rejecting adjacent channel interference is somewhat diminished.

  12. Photocathode non-uniformity contribution to the energy resolution of scintillators

    International Nuclear Information System (INIS)

    Mottaghian, M.; Koohi-Fayegh, R.; Ghal-Eh, N.; Etaati, G. R.

    2010-01-01

    This paper introduces the basics of the light transport simulation in scintillators and the wavelength-dependencies in the process. The non-uniformity measurement of the photocathode surface is undertaken, showing that for the photocathode used in this study the quantum efficiency falls to about 4% of its maximum value, especially in areas far from the centre. The wavelength-and position-dependent quantum efficiency is implemented in the Monte Carlo light transport code, showing that, the contribution of the photocathode non-uniformity to the energy resolution is estimated to be around 18%, when all position-and wavelength-dependencies are included. (authors)

  13. Joint Labeling Of Multiple Regions of Interest (Rois) By Enhanced Auto Context Models.

    Science.gov (United States)

    Kim, Minjeong; Wu, Guorong; Guo, Yanrong; Shen, Dinggang

    2015-04-01

    Accurate segmentation of a set of regions of interest (ROIs) in the brain images is a key step in many neuroscience studies. Due to the complexity of image patterns, many learning-based segmentation methods have been proposed, including auto context model (ACM) that can capture high-level contextual information for guiding segmentation. However, since current ACM can only handle one ROI at a time, neighboring ROIs have to be labeled separately with different ACMs that are trained independently without communicating each other. To address this, we enhance the current single-ROI learning ACM to multi-ROI learning ACM for joint labeling of multiple neighboring ROIs (called e ACM). First, we extend current independently-trained single-ROI ACMs to a set of jointly-trained cross-ROI ACMs, by simultaneous training of ACMs for all spatially-connected ROIs to let them to share their respective intermediate outputs for coordinated labeling of each image point. Then, the context features in each ACM can capture the cross-ROI dependence information from the outputs of other ACMs that are designed for neighboring ROIs. Second, we upgrade the output labeling map of each ACM with the multi-scale representation, thus both local and global context information can be effectively used to increase the robustness in characterizing geometric relationship among neighboring ROIs. Third, we integrate ACM into a multi-atlases segmentation paradigm, for encompassing high variations among subjects. Experiments on LONI LPBA40 dataset show much better performance by our e ACM, compared to the conventional ACM.

  14. Leveraging Non-Uniform Resources for Parallel Query Processing

    DEFF Research Database (Denmark)

    Mayr, Tobias; Bonnet, Philippe; Gehrke, Johannes

    2003-01-01

    Modular clusters are now composed of non- uniform nodes with different CPUs, disks or network cards so that customers can adapt the cluster configuration to the changing technologies and to their changing needs. This challenges dataflow parallelism as the primary load balancing technique of exist...

  15. Exact Reconstruction From Uniformly Attenuated Helical Cone-Beam Projections in SPECT

    International Nuclear Information System (INIS)

    Gullberg, Grant T.; Huang, Qiu; You, Jiangsheng; Zeng, Gengsheng L.

    2008-01-01

    In recent years the development of cone-beam reconstruction algorithms has been an active research area in x-ray computed tomography (CT), and significant progress has been made in the advancement of algorithms. Theoretically exact and computationally efficient analytical algorithms can be found in the literature. However, in single photon emission computed tomography (SPECT), published cone-beam reconstruction algorithms are either approximate or involve iterative methods. The SPECT reconstruction problem is more complicated due to degradations in the imaging detection process, one of which is the effect of attenuation of gamma ray photons. Attenuation should be compensated for to obtain quantitative results. In this paper, an analytical reconstruction algorithm for uniformly attenuated cone-beam projection data is presented for SPECT imaging. The algorithm adopts the DBH method, a procedure consisting of differentiation and backprojection followed by a finite inverse cosh-weighted Hilbert transform. The significance of the proposed approach is that a selected region of interest can be reconstructed even with a detector with a reduced field of view. The algorithm is designed for a general trajectory. However, to validate the algorithm, a numerical study was performed using a helical trajectory. The implementation is efficient and the simulation result is promising

  16. Optimization of relativistic backward wave oscillator with non-uniform slow wave structure and a resonant reflector

    International Nuclear Information System (INIS)

    Chen, Zaigao; Wang, Jianguo; Wang, Yue

    2015-01-01

    This letter optimizes synchronously 18 parameters of a relativistic backward wave oscillator with non-uniform slow wave structure (SWS) and a resonant reflector by using the parallel genetic algorithms and particle-in-cell simulation. The optimization results show that the generation efficiency of microwave from the electron beam has increased 32% compared to that of the original device. After optimization, the electromagnetic mode propagating in the resonant changes from the original TM 020 mode of reflector to higher-order TM 021 mode, which has a high reflection coefficient in a broader frequency range than that of the former. The modulation of current inside the optimized device is much deeper than that in the original one. The product of the electric field and current is defined. Observing this product, it is found that the interaction of the electron beam with the electromagnetic wave in the optimized device is much stronger than that in the original device, and at the rear part of SWS of the optimized device, the electron beam dominantly gives out the energy to the electromagnetic wave, leading to the higher generation efficiency of microwave than that of the original device

  17. RFID Benefits; Looking Beyond ROI

    National Research Council Canada - National Science Library

    Guilford, Shane; Kutis, Mark C

    2005-01-01

    ...) into the logistics process that are not captured by traditional Return on Investment (ROI) analysis. The authors seek to identify some of these benefits to determine their overall contribution to the value of new technology implementation...

  18. Non-coaxial superposition of vector vortex beams.

    Science.gov (United States)

    Aadhi, A; Vaity, Pravin; Chithrabhanu, P; Reddy, Salla Gangi; Prabakar, Shashi; Singh, R P

    2016-02-10

    Vector vortex beams are classified into four types depending upon spatial variation in their polarization vector. We have generated all four of these types of vector vortex beams by using a modified polarization Sagnac interferometer with a vortex lens. Further, we have studied the non-coaxial superposition of two vector vortex beams. It is observed that the superposition of two vector vortex beams with same polarization singularity leads to a beam with another kind of polarization singularity in their interaction region. The results may be of importance in ultrahigh security of the polarization-encrypted data that utilizes vector vortex beams and multiple optical trapping with non-coaxial superposition of vector vortex beams. We verified our experimental results with theory.

  19. An experimental comparison between forced convection burn-out in freon 12 flowing vertically upwards through uniformly and non-uniformly heated round tubes

    International Nuclear Information System (INIS)

    Stevens, G.F.; Elliott, D.F.; Wood, R.W.

    1965-05-01

    Some correlations of forced convection burn-out data are based on the approximate linearity of the relationship between burn-out heat flux and the channel-averaged quality at the burn-out point. These correlations perform satisfactorily on data obtained from uniformly heated configurations. Therefore the further inference is sometimes made that the burn-out heat flux is uniquely related to the quality, and that the burn-out in non-uniformly heated configurations can be calculated from measurements made with uniform heating. This report presents burn-out data for Freon 12 flowing vertically upwards through both uniformly and non-uniformly heated round tubes. This data shows that the quality at burn-out does depend on the heat flux profile, and that the inference mentioned above is not justified. (author)

  20. The magneto-optical properties of non-uniform graphene nanoribbons

    Science.gov (United States)

    Chung, Hsien-Ching; Lin, Ming-Fa

    2015-03-01

    When synthesizing few-layer graphene nanoribbons (GNRs), non-uniform GNRs would be made simultaneously. Recently, the non-uniform GNRs, which is a stack of two GNRs with unequal widths, have been fabricated by mechanically exfoliated from bulk graphite. Some theoretical predictions have been reported, such as gap opening and transport properties. Under the influence of magnetic fields, magnetic quantization takes place and drastically changes the electronic properties. By tuning the geometric configuration, four categories of magneto-electronic spectra are exhibited. (1) The spectrum is mostly contributed by quasi-Landau levels (QLLs) of monolayer GNRs. (2) The spectrum displays two groups of QLLs, and the non-uniform GNR behaves like a bilayer one. (3) An intermediate category, the spectrum is composite disordered. (4) The spectrum presents the coexistence of monolayer and bilayer spectra. In this work, the magneto-electronic and optical properties for different geometric configurations are given, such as energy dispersions, density of states, wave functions, and magneto-absorption spectra are presented. Furthermore, the transformation between monolayer and bilayer spectra as well as the coexistence of monolayer and bilayer spectra are discussed in detail. One of us (Hsien-Ching Chung) thanks Ming-Hui Chung and Su-Ming Chen for financial support. This work was supported in part by the National Science Council of Taiwan under Grant Number 98-2112-M-006-013-MY4.

  1. Polarized Uniform Linear Array System: Beam Radiation Pattern, Beamforming Diversity Order, and Channel Capacity

    Directory of Open Access Journals (Sweden)

    Xin Su

    2015-01-01

    Full Text Available There have been many studies regarding antenna polarization; however, there have been few publications on the analysis of the channel capacity for polarized antenna systems using the beamforming technique. According to Chung et al., the channel capacity is determined by the density of scatterers and the transmission power, which is obtained based on the assumption that scatterers are uniformly distributed on a 3D spherical scattering model. However, it contradicts the practical scenario, where scatterers may not be uniformly distributed under outdoor environment, and lacks the consideration of fading channel gain. In this study, we derive the channel capacity of polarized uniform linear array (PULA systems using the beamforming technique in a practical scattering environment. The results show that, for PULA systems, the channel capacity, which is boosted by beamforming diversity, can be determined using the channel gain, beam radiation pattern, and beamforming diversity order (BDO, where the BDO is dependent on the antenna characteristics and array configurations.

  2. Beam-beam interactions in p-p storage rings

    CERN Document Server

    Keil, Eberhard

    1977-01-01

    There are two lectures. The first one (sections 2 to 5) deals with the theoretical aspects of the beam-beam interaction, and the second one (sections 6 to 8) describes the results of experiments in the ISR. Section 3 describes the strength of the beam-beam interaction in terms of the linear tune shift Delta Q which has been calculated for several models. Because of the non-uniform density distribution in the beam the force results in a tune spread. This can be calculated by a perturbation method as explained in section 4. Section 5 discusses the simulation of the beam-beam interaction on a computer. Finally, section 6 reviews beam-beam phenomena observed in the CERN-ISR. These include the absence of observable beam-beam effects in unbunched beams, overlap knock-out resonances, collisions between a low-energy beam and a high-intensity stack, experiments with a nonlinear lens, and experiments with a high- beta insertion. (20 refs).

  3. Ion beam induced charge and cathodoluminescence imaging of response uniformity of CVD diamond radiation detectors

    CERN Document Server

    Sellin, P J; Galbiati, A; Maghrabi, M; Townsend, P D

    2002-01-01

    The uniformity of response of CVD diamond radiation detectors produced from high quality diamond film, with crystallite dimensions of >100 mu m, has been studied using ion beam induced charge imaging. A micron-resolution scanning alpha particle beam was used to produce maps of pulse height response across the device. The detectors were fabricated with a single-sided coplanar electrode geometry to maximise their sensitivity to the surface region of the diamond film where the diamond crystallites are highly ordered. High resolution ion beam induced charge images of single crystallites were acquired that demonstrate variations in intra-crystallite charge transport and the termination of charge transport at the crystallite boundaries. Cathodoluminescence imaging of the same crystallites shows an inverse correlation between the density of radiative centres and regions of good charge transport.

  4. Measuring Digital Signage ROI : A combination of Digital Signage and Mobile Advertising as a method for measuring Digtal Signage ROI

    OpenAIRE

    Helander, Fredrik

    2010-01-01

    Marketing has changed a lot the past decade. New modern marketing channels have been developed and marketing have become more effective. This has affected the expectations advertisers have on advertising channels. One thing advertisers increasingly expect is to be able to efficiently measure the result of advertising, the ROI. A method for measuring ROI of digital signage is in focus in this study. The measurement is enabled by a combination of digital signage and mobile advertising. First a ...

  5. A Non-Uniformly Under-Sampled Blade Tip-Timing Signal Reconstruction Method for Blade Vibration Monitoring

    Directory of Open Access Journals (Sweden)

    Zheng Hu

    2015-01-01

    Full Text Available High-speed blades are often prone to fatigue due to severe blade vibrations. In particular, synchronous vibrations can cause irreversible damages to the blade. Blade tip-timing methods (BTT have become a promising way to monitor blade vibrations. However, synchronous vibrations are unsuitably monitored by uniform BTT sampling. Therefore, non-equally mounted probes have been used, which will result in the non-uniformity of the sampling signal. Since under-sampling is an intrinsic drawback of BTT methods, how to analyze non-uniformly under-sampled BTT signals is a big challenge. In this paper, a novel reconstruction method for non-uniformly under-sampled BTT data is presented. The method is based on the periodically non-uniform sampling theorem. Firstly, a mathematical model of a non-uniform BTT sampling process is built. It can be treated as the sum of certain uniform sample streams. For each stream, an interpolating function is required to prevent aliasing in the reconstructed signal. Secondly, simultaneous equations of all interpolating functions in each sub-band are built and corresponding solutions are ultimately derived to remove unwanted replicas of the original signal caused by the sampling, which may overlay the original signal. In the end, numerical simulations and experiments are carried out to validate the feasibility of the proposed method. The results demonstrate the accuracy of the reconstructed signal depends on the sampling frequency, the blade vibration frequency, the blade vibration bandwidth, the probe static offset and the number of samples. In practice, both types of blade vibration signals can be particularly reconstructed by non-uniform BTT data acquired from only two probes.

  6. Enceladus's crust as a non-uniform thin shell: I tidal deformations

    Science.gov (United States)

    Beuthe, Mikael

    2018-03-01

    The geologic activity at Enceladus's south pole remains unexplained, though tidal deformations are probably the ultimate cause. Recent gravity and libration data indicate that Enceladus's icy crust floats on a global ocean, is rather thin, and has a strongly non-uniform thickness. Tidal effects are enhanced by crustal thinning at the south pole, so that realistic models of tidal tectonics and dissipation should take into account the lateral variations of shell structure. I construct here the theory of non-uniform viscoelastic thin shells, allowing for depth-dependent rheology and large lateral variations of shell thickness and rheology. Coupling to tides yields two 2D linear partial differential equations of the fourth order on the sphere which take into account self-gravity, density stratification below the shell, and core viscoelasticity. If the shell is laterally uniform, the solution agrees with analytical formulas for tidal Love numbers; errors on displacements and stresses are less than 5% and 15%, respectively, if the thickness is less than 10% of the radius. If the shell is non-uniform, the tidal thin shell equations are solved as a system of coupled linear equations in a spherical harmonic basis. Compared to finite element models, thin shell predictions are similar for the deformations due to Enceladus's pressurized ocean, but differ for the tides of Ganymede. If Enceladus's shell is conductive with isostatic thickness variations, surface stresses are approximately inversely proportional to the local shell thickness. The radial tide is only moderately enhanced at the south pole. The combination of crustal thinning and convection below the poles can amplify south polar stresses by a factor of 10, but it cannot explain the apparent time lag between the maximum plume brightness and the opening of tiger stripes. In a second paper, I will study the impact of a non-uniform crust on tidal dissipation.

  7. Normalisation: ROI optimal treatment planning - SNDH pattern

    International Nuclear Information System (INIS)

    Shilvat, D.V.; Bhandari, Virendra; Tamane, Chandrashekhar; Pangam, Suresh

    2001-01-01

    Dose precision maximally to the target / ROI (Region of Interest), taking care of tolerance dose of normal tissue is the aim of ideal treatment planning. This goal is achieved with advanced modalities such as, micro MLC, simulator and 3-dimensional treatment planning system. But SNDH PATTERN uses minimum available resources as, ALCYON II Telecobalt unit, CT Scan, MULTIDATA 2-dimensional treatment planning system to their maximum utility and reaches to the required precision, same as that with advance modalities. Among the number of parameters used, 'NORMALISATION TO THE ROI' will achieve the aim of the treatment planning effectively. This is dealing with an example of canal of esophagus modified treatment planning based on SNDH pattern. Results are attractive and self explanatory. By implementing SNDH pattern, the QUALITY INDEX of treatment plan will reach to greater than 90%, with substantial reduction in dose to the vital organs. Aim is to utilize the minimum available resources efficiently to achieve highest possible precision for delivering homogenous dose to ROI while taking care of tolerance dose to vital organs

  8. A poloidal non-uniformity of the collisionless parallel current in a tokamak plasma

    Energy Technology Data Exchange (ETDEWEB)

    Romannikov, A.; Fenzi-Bonizec, C

    2005-07-01

    The collisionless distortion of the ion (electron) distribution function at certain points on a magnetic surface is studied in the framework of a simple model of a large aspect ratio tokamak plasma. The flow velocity driven by this distortion is calculated. The possibility of an additional non-uniform collisionless parallel current density on a magnetic surface, other than the known neo-classical non-uniformity is shown. The difference between the parallel current density on the low and high field side of a magnetic surface is close to the neoclassical bootstrap current density. The first Tore-Supra experimental test indicates the possibility of the poloidal non-uniformity of the parallel current density. (authors)

  9. Simulation of Non-Uniform Electron Beams in the Gyrotron Electron-Optical System

    Science.gov (United States)

    Louksha, O. I.; Trofimov, P. A.

    2018-04-01

    New calculated data on the effect of emission inhomogeneities on the quality of the electron beam, which is formed in an electron-optical system of a gyrotron, have been obtained. The calculations were based on emission current density distributions, which were measured for the different cathodes in the gyrotron of Peter the Great St. Petersburg Polytechnic University. A satisfactory agreement between the experimental and calculated data on the influence of emission nonuniformities on the velocity spread of electrons has been shown. The necessity of considering the real distribution of the emission current density over the cathode surface to determine the main parameters of the electron beam—the velocity and energy spreads of the electrons, spatial structure of the beam, and coefficient of reflection of electrons from the magnetic mirror—has been demonstrated. The maximum level of emission inhomogeneities, which are permissible for effective work of gyrotrons, has been discussed.

  10. Effective electrodiffusion equation for non-uniform nanochannels.

    Science.gov (United States)

    Marini Bettolo Marconi, Umberto; Melchionna, Simone; Pagonabarraga, Ignacio

    2013-06-28

    We derive a one-dimensional formulation of the Planck-Nernst-Poisson equation to describe the dynamics of a symmetric binary electrolyte in channels whose section is nanometric and varies along the axial direction. The approach is in the spirit of the Fick-Jacobs diffusion equation and leads to a system of coupled equations for the partial densities which depends on the charge sitting at the walls in a non-trivial fashion. We consider two kinds of non-uniformities, those due to the spatial variation of charge distribution and those due to the shape variation of the pore and report one- and three-dimensional solutions of the electrokinetic equations.

  11. A novel scene-based non-uniformity correction method for SWIR push-broom hyperspectral sensors

    Science.gov (United States)

    Hu, Bin-Lin; Hao, Shi-Jing; Sun, De-Xin; Liu, Yin-Nian

    2017-09-01

    A novel scene-based non-uniformity correction (NUC) method for short-wavelength infrared (SWIR) push-broom hyperspectral sensors is proposed and evaluated. This method relies on the assumption that for each band there will be ground objects with similar reflectance to form uniform regions when a sufficient number of scanning lines are acquired. The uniform regions are extracted automatically through a sorting algorithm, and are used to compute the corresponding NUC coefficients. SWIR hyperspectral data from airborne experiment are used to verify and evaluate the proposed method, and results show that stripes in the scenes have been well corrected without any significant information loss, and the non-uniformity is less than 0.5%. In addition, the proposed method is compared to two other regular methods, and they are evaluated based on their adaptability to the various scenes, non-uniformity, roughness and spectral fidelity. It turns out that the proposed method shows strong adaptability, high accuracy and efficiency.

  12. Additive non-uniform random sampling in superimposed fiber Bragg grating strain gauge

    Science.gov (United States)

    Ma, Y. C.; Liu, H. Y.; Yan, S. B.; Yang, Y. H.; Yang, M. W.; Li, J. M.; Tang, J.

    2013-05-01

    This paper demonstrates an additive non-uniform random sampling and interrogation method for dynamic and/or static strain gauge using a reflection spectrum from two superimposed fiber Bragg gratings (FBGs). The superimposed FBGs are designed to generate non-equidistant space of a sensing pulse train in the time domain during dynamic strain gauge. By combining centroid finding with smooth filtering methods, both the interrogation speed and accuracy are improved. A 1.9 kHz dynamic strain is measured by generating an additive non-uniform randomly distributed 2 kHz optical sensing pulse train from a mean 500 Hz triangular periodically changing scanning frequency.

  13. Bridge density functional approximation for non-uniform hard core repulsive Yukawa fluid

    International Nuclear Information System (INIS)

    Zhou Shiqi

    2008-01-01

    In this work, a bridge density functional approximation (BDFA) (J. Chem. Phys. 112, 8079 (2000)) for a non-uniform hard-sphere fluid is extended to a non-uniform hard-core repulsive Yukawa (HCRY) fluid. It is found that the choice of a bulk bridge functional approximation is crucial for both a uniform HCRY fluid and a non-uniform HCRY fluid. A new bridge functional approximation is proposed, which can accurately predict the radial distribution function of the bulk HCRY fluid. With the new bridge functional approximation and its associated bulk second order direct correlation function as input, the BDFA can be used to well calculate the density profile of the HCRY fluid subjected to the influence of varying external fields, and the theoretical predictions are in good agreement with the corresponding simulation data. The calculated results indicate that the present BDFA captures quantitatively the phenomena such as the coexistence of solid-like high density phase and low density gas phase, and the adsorption properties of the HCRY fluid, which qualitatively differ from those of the fluids combining both hard-core repulsion and an attractive tail. (condensed matter: structure, thermal and mechanical properties)

  14. Measurements of lateral penumbra for uniform scanning proton beams under various beam delivery conditions and comparison to the XiO treatment planning system

    International Nuclear Information System (INIS)

    Rana, Suresh; Zeidan, Omar; Ramirez, Eric; Rains, Michael; Gao, Junfang; Zheng, Yuanshui

    2013-01-01

    Purpose: The main purposes of this study were to (1) investigate the dependency of lateral penumbra (80%–20% distance) of uniform scanning proton beams on various factors such as air gap, proton range, modulation width, compensator thickness, and depth, and (2) compare the lateral penumbra calculated by a treatment planning system (TPS) with measurements.Methods: First, lateral penumbra was measured using solid–water phantom and radiographic films for (a) air gap, ranged from 0 to 35 cm, (b) proton range, ranged from 8 to 30 cm, (c) modulation, ranged from 2 to 10 cm, (d) compensator thickness, ranged from 0 to 20 cm, and (e) depth, ranged from 7 to 15 cm. Second, dose calculations were computed in a virtual water phantom using the XiO TPS with pencil beam algorithm for identical beam conditions and geometrical configurations that were used for the measurements. The calculated lateral penumbra was then compared with the measured one for both the horizontal and vertical scanning magnets of our uniform scanning proton beam delivery system.Results: The results in the current study showed that the lateral penumbra of horizontal scanning magnet was larger (up to 1.4 mm for measurement and up to 1.0 mm for TPS) compared to that of vertical scanning magnet. Both the TPS and measurements showed an almost linear increase in lateral penumbra with increasing air gap as it produced the greatest effect on lateral penumbra. Lateral penumbra was dependent on the depth and proton range. Specifically, the width of lateral penumbra was found to be always lower at shallower depth than at deeper depth within the spread out Bragg peak (SOBP) region. The lateral penumbra results were less sensitive to the variation in the thickness of compensator, whereas lateral penumbra was independent of modulation. Overall, the comparison between the results of TPS with that of measurements indicates a good agreement for lateral penumbra, with TPS predicting higher values compared to

  15. The use of intensity-modulated radiation therapy photon beams for improving the dose uniformity of electron beams shaped with MLC.

    Science.gov (United States)

    Mosalaei, Homeira; Karnas, Scott; Shah, Sheel; Van Doodewaard, Sharon; Foster, Tim; Chen, Jeff

    2012-01-01

    Electrons are ideal for treating shallow tumors and sparing adjacent normal tissue. Conventionally, electron beams are collimated by cut-outs that are time-consuming to make and difficult to adapt to tumor shape throughout the course of treatment. We propose that electron cut-outs can be replaced using photon multileaf collimator (MLC). Two major problems of this approach are that the scattering of electrons causes penumbra widening because of a large air gap, and available commercial treatment planning systems (TPSs) do not support MLC-collimated electron beams. In this study, these difficulties were overcome by (1) modeling electron beams collimated by photon MLC for a commercial TPS, and (2) developing a technique to reduce electron beam penumbra by adding low-energy intensity-modulated radiation therapy (IMRT) photons (4 MV). We used blocks to simulate MLC shielding in the TPS. Inverse planning was used to optimize boost photon beams. This technique was applied to a parotid and a central nervous system (CNS) clinical case. Combined photon and electron plans were compared with conventional plans and verified using ion chamber, film, and a 2D diode array. Our studies showed that the beam penumbra for mixed beams with 90 cm source to surface distance (SSD) is comparable with electron applicators and cut-outs at 100 cm SSD. Our mixed-beam technique yielded more uniform dose to the planning target volume and lower doses to various organs at risk for both parotid and CNS clinical cases. The plans were verified with measurements, with more than 95% points passing the gamma criteria of 5% in dose difference and 5 mm for distance to agreement. In conclusion, the study has demonstrated the feasibility and potential advantage of using photon MLC to collimate electron beams with boost photon IMRT fields. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  16. Optically induced rotation of Rayleigh particles by vortex beams with different states of polarization

    International Nuclear Information System (INIS)

    Li, Manman; Yan, Shaohui; Yao, Baoli; Liang, Yansheng; Lei, Ming; Yang, Yanlong

    2016-01-01

    Optical vortex beams carry optical orbital angular momentum (OAM) and can induce an orbital motion of trapped particles in optical trapping. We show that the state of polarization (SOP) of vortex beams will affect the details of this optically induced orbital motion to some extent. Numerical results demonstrate that focusing the vortex beams with circular, radial or azimuthal polarizations can induce a uniform orbital motion on a trapped Rayleigh particle, while in the focal field of the vortex beam with linear polarization the particle experiences a non-uniform orbital motion. Among the formers, the vortex beam with circular polarization induces a maximum optical torque on the particle. Furthermore, by varying the topological charge of the vortex beams, the vortex beam with circular polarization gives rise to an optimum torque superior to those given by the other three vortex beams. These facts suggest that the circularly polarized vortex beam is more suitable for rotating particles. - Highlights: • States of polarization of vortex beams affect the optically induced orbital motion of particles. • The dependences of the force and orbital torque on the topological charge, the size and the absorptivity of particles were calculated. • Focused vortex beams with circular, radial or azimuthal polarizations induce a uniform orbital motion on particles. • Particles experience a non-uniform orbital motion in the focused linearly polarized vortex beam. • The circularly polarized vortex beam is a superior candidate for rotating particles.

  17. Beam-beam interactions in p-p storage rings

    International Nuclear Information System (INIS)

    Keil, E.

    1977-01-01

    There are two lectures: the first part of this paper (sections 2 to 5) deals with the theoretical aspects of the beam-beam interaction, and the second part (sections 6 to 8) describe the results of experiments in the ISR. Section 3 describes the strengths of the beam-beam interaction in terms of the linear tune shift ΔQ which has been calculated for several models. Because of the non-uniform density distribution in the beam the force results in a tune spread. This can be calculated by a perturbation method as explained in section 4. Section 5 discusses the simulation of the beam-beam interaction on a computer. Finally, section 6 reviews beam-beam phenomena observed in the CERN-ISR. These include the absence of observable beam-beam effects in unbunched beams, overlap knock-out resonances, collisions between a low-energy beam and a high-intensity stack, experiments with a nonlinear lens, and experiments with a high-β insertion. Section 7 contains a few concluding remarks. (Auth.)

  18. Attenuation maps for SPECT determined using cone beam transmission computed tomography

    International Nuclear Information System (INIS)

    Manglos, S.H.; Bassano, D.A.; Duxbury, C.E.; Capone, R.B.

    1990-01-01

    This paper presents a new method for measuring non-uniform attenuation maps, using a cone beam geometry CT scan acquired on a standard rotating gamma camera normally used for SPECT imaging. The resulting map is intended for use in non-uniform attenuation compensation of SPECT images. The method was implemented using a light-weight point source holder attached to the camera. A cone beam collimator may be used on the gamma camera, but the cone beam CT scans may also be acquired without collimator. In either implementation, the advantages include very high efficiency and resolution limited not by the collimator but by the intrinsic camera resolution (about 4 mm). Several phantoms tested the spatial uniformity, noise, linearity as a function of attenuation coefficient, and spatial resolution. Good quality attenuation maps were obtained, at least for the central slices where no truncation was present

  19. Analysis of Quantum Effects in Non-Uniformly Doped MOS Structures

    National Research Council Canada - National Science Library

    Fiegna, Claudio

    1997-01-01

    This paper presents results from the self-consistent solution of Schrodinger and Poisson equations obtained in one-dimensional non-uniformly doped MOS structures suitable for the fabrication of very short transistors...

  20. SU-F-J-183: Interior Region-Of-Interest Tomography by Using Inverse Geometry System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K; Kim, D; Kang, S; Kim, T; Shin, D; Cho, M; Noh, Y; Suh, T [Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2016-06-15

    Purpose: The inverse geometry computed tomography (IGCT) composed of multiple source and small size detector has several merits such as reduction of scatter effect and large volumetric imaging within one rotation without cone-beam artifact, compared to conventional cone-beam computed tomography (CBCT). By using this multi-source characteristics, we intend to present a selective and multiple interior region-of-interest (ROI) imaging method by using a designed source on-off sequence of IGCT. Methods: All of the IGCT sources are operated one by one sequentially, and each projection in the shape of narrow cone-beam covers its own partial volume of full field of view (FOV) determined from system geometry. Thus, through controlling multi source operation, limited irradiation within ROI is possible and selective radon space data for ROI imaging can be acquired without additional X-ray filtration. With this feature, we designed a source on-off sequence for multi ROI-IGCT imaging, and projections of ROI-IGCT were generated by using the on-off sequence. Multi ROI-IGCT images were reconstructed by using filtered back-projection algorithm. All these imaging process of our study has been performed by utilizing digital phantom and patient CT data. ROI-IGCT images of the phantom were compared to CBCT image and the phantom data for the image quality evaluation. Results: Image quality of ROI-IGCT was comparable to that of CBCT. However, the distal axial-plane from the FOV center, large cone-angle region, ROI-IGCT showed uniform image quality without significant cone-beam artifact contrary to CBCT. Conclusion: ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. Projection of ROI-IGCT is performed by selective irradiation, hence unnecessary imaging dose to non-interest region can be reduced. In this regard, it seems to be useful for diagnostic or image guidance purpose in radiotherapy such as low dose target localization and

  1. SU-F-J-183: Interior Region-Of-Interest Tomography by Using Inverse Geometry System

    International Nuclear Information System (INIS)

    Kim, K; Kim, D; Kang, S; Kim, T; Shin, D; Cho, M; Noh, Y; Suh, T

    2016-01-01

    Purpose: The inverse geometry computed tomography (IGCT) composed of multiple source and small size detector has several merits such as reduction of scatter effect and large volumetric imaging within one rotation without cone-beam artifact, compared to conventional cone-beam computed tomography (CBCT). By using this multi-source characteristics, we intend to present a selective and multiple interior region-of-interest (ROI) imaging method by using a designed source on-off sequence of IGCT. Methods: All of the IGCT sources are operated one by one sequentially, and each projection in the shape of narrow cone-beam covers its own partial volume of full field of view (FOV) determined from system geometry. Thus, through controlling multi source operation, limited irradiation within ROI is possible and selective radon space data for ROI imaging can be acquired without additional X-ray filtration. With this feature, we designed a source on-off sequence for multi ROI-IGCT imaging, and projections of ROI-IGCT were generated by using the on-off sequence. Multi ROI-IGCT images were reconstructed by using filtered back-projection algorithm. All these imaging process of our study has been performed by utilizing digital phantom and patient CT data. ROI-IGCT images of the phantom were compared to CBCT image and the phantom data for the image quality evaluation. Results: Image quality of ROI-IGCT was comparable to that of CBCT. However, the distal axial-plane from the FOV center, large cone-angle region, ROI-IGCT showed uniform image quality without significant cone-beam artifact contrary to CBCT. Conclusion: ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. Projection of ROI-IGCT is performed by selective irradiation, hence unnecessary imaging dose to non-interest region can be reduced. In this regard, it seems to be useful for diagnostic or image guidance purpose in radiotherapy such as low dose target localization and

  2. Additive non-uniform random sampling in superimposed fiber Bragg grating strain gauge

    International Nuclear Information System (INIS)

    Ma, Y C; Liu, H Y; Yan, S B; Li, J M; Tang, J; Yang, Y H; Yang, M W

    2013-01-01

    This paper demonstrates an additive non-uniform random sampling and interrogation method for dynamic and/or static strain gauge using a reflection spectrum from two superimposed fiber Bragg gratings (FBGs). The superimposed FBGs are designed to generate non-equidistant space of a sensing pulse train in the time domain during dynamic strain gauge. By combining centroid finding with smooth filtering methods, both the interrogation speed and accuracy are improved. A 1.9 kHz dynamic strain is measured by generating an additive non-uniform randomly distributed 2 kHz optical sensing pulse train from a mean 500 Hz triangular periodically changing scanning frequency. (paper)

  3. Low-frequency electrostatic dust-modes in a non-uniform

    Indian Academy of Sciences (India)

    A self-consistent and general description of obliquely propagating low-frequency electrostatic dust-modes in a non-uniform magnetized dusty plasma system has been presented. A number of different situations, which correspond to different low-frequency electrostatic dust-modes, namely, dust-acoustic mode, dust-drift ...

  4. Non-uniform cosine modulated filter banks using meta-heuristic algorithms in CSD space

    Directory of Open Access Journals (Sweden)

    Shaeen Kalathil

    2015-11-01

    Full Text Available This paper presents an efficient design of non-uniform cosine modulated filter banks (CMFB using canonic signed digit (CSD coefficients. CMFB has got an easy and efficient design approach. Non-uniform decomposition can be easily obtained by merging the appropriate filters of a uniform filter bank. Only the prototype filter needs to be designed and optimized. In this paper, the prototype filter is designed using window method, weighted Chebyshev approximation and weighted constrained least square approximation. The coefficients are quantized into CSD, using a look-up-table. The finite precision CSD rounding, deteriorates the filter bank performances. The performances of the filter bank are improved using suitably modified meta-heuristic algorithms. The different meta-heuristic algorithms which are modified and used in this paper are Artificial Bee Colony algorithm, Gravitational Search algorithm, Harmony Search algorithm and Genetic algorithm and they result in filter banks with less implementation complexity, power consumption and area requirements when compared with those of the conventional continuous coefficient non-uniform CMFB.

  5. Effects of non-uniformities on electrical conduction in weakly ionized plasmas

    International Nuclear Information System (INIS)

    Numano, M.; Murakami, Y.; Nitta, T.

    1989-01-01

    The effect of non-uniformities on the flow of electric current in weakly ionized plasmas is investigated by taking into account the ion slip as well as the Hall current. An Ohm's law for a non-uniform plasma is derived, from which the formula previously obtained by Numano, i.e. an extension of Rosa's equation, is obtainable as a special case. Making use of this new Ohm's law, the effective electrical conductivity and the effective Hall parameter are determined for isotropically turbulent plasmas. It is found that when the ion-slip effect is absent they are in good agreement with the results obtained previously. (author)

  6. Non-uniform-tilt-modulated fiber Bragg grating for temperature-immune micro-displacement measurement

    International Nuclear Information System (INIS)

    Guo, Tuan; Chen, Chengkun; Albert, Jacques

    2009-01-01

    Temperature-immune micro-displacement measurement is demonstrated by using a Gaussian-chirped tilted fiber Bragg grating (TFBG). The internal tilt angles of the sensing TFBG are effectively modulated via a displacement-induced Gaussian-strain-gradient along the specially designed bending cantilever beam. The phase mismatch between different effective pitches and tilt angles weakens the core-to-cladding mode coupling as the beam is displaced. While the power of the ghost mode resonance in transmission shows a strong sensitivity to the displacement, it is immune from spatially uniform temperature changes. Ghost-power-referenced displacement measurement and temperature-insensitive property are experimentally achieved for this cost-effective sensing device

  7. Tunable pinning effects produced by non-uniform antidot arrays in YBCO thin films

    Energy Technology Data Exchange (ETDEWEB)

    George, J.; Jones, A.; Al-Qurainy, M. [Institute for Superconducting and Electronic Materials, University of Wollongong, NSW (Australia); Fedoseev, S.A. [Institute for Superconducting and Electronic Materials, University of Wollongong, NSW (Australia); Centre for Medical Radiation Physics, University of Wollongong, NSW (Australia); Rosenfeld, A. [Centre for Medical Radiation Physics, University of Wollongong, NSW (Australia); Pan, A.V. [Institute for Superconducting and Electronic Materials, University of Wollongong, NSW (Australia); National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation)

    2017-04-15

    Uniform, graded and spaced arrays of 3 μm triangular antidots in pulsed laser deposited YBa{sub 2}Cu{sub 3}O{sub 7} (YBCO) superconducting thin films are compared by examining the improvements in the critical current density J{sub c} they produced. The comparison is made to establish the role of their lithographically defined (non-)uniformity and the effectiveness to control and/or enhance the critical current density. It is found that almost all types of non-uniform arrays, including graded ones enhance J{sub c} over the broad applied magnetic field and temperature range due to the modified critical state. Whereas uniform arrays of antidots either reduce or produce no effect on J{sub c} compared to the original (as-deposited) thin films. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. Formation of a uniform ion beam using octupole magnets for BioLEIR facility at CERN

    Science.gov (United States)

    Amin, T.; Barlow, R.; Ghithan, S.; Roy, G.; Schuh, S.

    2018-04-01

    The possibility to transform the Low Energy Ion Ring (LEIR) accelerator at CERN into a multidisciplinary, biomedical research facility (BioLEIR) was investigated based on a request from the biomedical community. BioLEIR aims to provide a unique facility with a range of fully stripped ion beams (e.g. He, Li, Be, B, C, N, O) and energies suitable for multidisciplinary biomedical, clinically-oriented research. Two horizontal and one vertical beam transport lines have been designed for transporting the extracted beam from LEIR to three experimental end-stations. The vertical beamline was designed for a maximum energy of 75 MeV/u, while the two horizontal beamlines shall deliver up to a maximum energy of 440 MeV/u. A pencil beam of 4.3 mm FWHM (Full Width Half Maximum) as well as a homogeneous broad beam of 40 × 40 mm2, with a beam homogeneity better than ±4%, are available at the first horizontal (H1) irradiation point, while only a pencil beam is available at the second horizontal (H2) and vertical (V) irradiation points. The H1 irradiation point shall be used to conduct systematic studies of the radiation effect from different ion species on cell-lines. The H1 beamline was designed to utilize two octupole magnets which transform the Gaussian beam distribution at the target location into an approximately uniformly distributed rectangular beam. In this paper, we report on the multi-particle tracking calculations performed using MAD-X software suite for the H1 beam optics to arrive at a homogeneous broad beam on target using nonlinear focusing techniques, and on those to create a Gaussian pencil beam on target by adjusting quadrupoles strengths and positions.

  9. Research on Creep Relaxation Non-uniformity and Effect on Performance of Combined Rotor

    Science.gov (United States)

    Liu, Qingya; He, Jingfei; Zhao, Lijia

    2017-11-01

    The combined rotor of gas turbine is connected by a certain number of rod bolts. It works in the high temperature environment for a long time, and the rod bolts will creep and relax. Under the influence of elastic interaction, the loss of pretightening force of rod bolts at different positions is non-uniform, which will cause the connection of the combined rotor to be out of tune. In this paper, the creep relaxation non-uniformity model for a class F heavy duty gas turbine is established. On the basis of this, the performance degradation and structural strength change of combined rotor resulting from creep relaxation non-uniformity of rod bolts are studied. The results show that the ratio of preload mistuning increases with time and then converges, and there is a threshold inflection point in about seven thousand hours.

  10. An Investigation into Conversion from Non-Uniform Rational B-Spline Boundary Representation Geometry to Constructive Solid Geometry

    Science.gov (United States)

    2015-12-01

    ARL-SR-0347 ● DEC 2015 US Army Research Laboratory An Investigation into Conversion from Non-Uniform Rational B-Spline Boundary...US Army Research Laboratory An Investigation into Conversion from Non-Uniform Rational B-Spline Boundary Representation Geometry to...from Non-Uniform Rational B-Spline Boundary Representation Geometry to Constructive Solid Geometry 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c

  11. Human thermal sensation and comfort in a non-uniform environment with personalized heating.

    Science.gov (United States)

    Deng, Qihong; Wang, Runhuai; Li, Yuguo; Miao, Yufeng; Zhao, Jinping

    2017-02-01

    Thermal comfort in traditionally uniform environment is apparent and can be improved by increasing energy expenses. To save energy, non-uniform environment implemented by personalized conditioning system attracts considerable attention, but human response in such environment is unclear. To investigate regional- and whole-body thermal sensation and comfort in a cool environment with personalized heating. In total 36 subjects (17 males and 19 females) including children, adults and the elderly, were involved in our experiment. Each subject was first asked to sit on a seat in an 18°C chamber (uniform environment) for 40min and then sit on a heating seat in a 16°C chamber (non-uniform environment) for another 40min after 10min break. Subjects' regional- and whole-body thermal sensation and comfort were surveyed by questionnaire and their skin temperatures were measured by wireless sensors. We statistically analyzed subjects' thermal sensation and comfort and their skin temperatures in different age and gender groups and compared them between the uniform and non-uniform environments. Overall thermal sensation and comfort votes were respectively neutral and just comfortable in 16°C chamber with personalized heating, which were significantly higher than those in 18°C chamber without heating (pthermal sensation and comfort was consistent in subjects of different age and gender. However, adults and the females were more sensitive to the effect of personalized heating and felt cooler and less comfort than children/elderly and the males respectively. Variations of the regional thermal sensation/comfort across human body were consistent with those of skin temperature. Personalized heating significantly improved human thermal sensation and comfort in non-uniform cooler environment, probably due to the fact that it increased skin temperature. However, the link between thermal sensation/comfort and variations of skin temperature is rather complex and warrant further

  12. Reproducibility of CT bone dosimetry: Operator versus automated ROI definition

    International Nuclear Information System (INIS)

    Louis, O.; Luypaert, R.; Osteaux, M.; Kalender, W.

    1988-01-01

    Intrasubject reproducibility with repeated determination of vertebral mineral density from a given set of CT images was investigated. The region of interest (ROI) in 10 patient scans was selected by four independent operators either manually or with an automated procedure separating cortical and spongeous bone, the operators being requested to interact in ROI selection. The mean intrasubject variation was found to be much lower with the automated process (0.3 to 0.6%) than with the conventional method (2.5 to 5.2%). In a second study, 10 patients were examined twice to determine the reproducibility of CT slice selection by the operator. The errors were of the same order of magnitude as in ROI selection. (orig.)

  13. Advanced GF(32) nonbinary LDPC coded modulation with non-uniform 9-QAM outperforming star 8-QAM.

    Science.gov (United States)

    Liu, Tao; Lin, Changyu; Djordjevic, Ivan B

    2016-06-27

    In this paper, we first describe a 9-symbol non-uniform signaling scheme based on Huffman code, in which different symbols are transmitted with different probabilities. By using the Huffman procedure, prefix code is designed to approach the optimal performance. Then, we introduce an algorithm to determine the optimal signal constellation sets for our proposed non-uniform scheme with the criterion of maximizing constellation figure of merit (CFM). The proposed nonuniform polarization multiplexed signaling 9-QAM scheme has the same spectral efficiency as the conventional 8-QAM. Additionally, we propose a specially designed GF(32) nonbinary quasi-cyclic LDPC code for the coded modulation system based on the 9-QAM non-uniform scheme. Further, we study the efficiency of our proposed non-uniform 9-QAM, combined with nonbinary LDPC coding, and demonstrate by Monte Carlo simulation that the proposed GF(23) nonbinary LDPC coded 9-QAM scheme outperforms nonbinary LDPC coded uniform 8-QAM by at least 0.8dB.

  14. Restoration of non-uniform exposure motion blurred image

    Science.gov (United States)

    Luo, Yuanhong; Xu, Tingfa; Wang, Ningming; Liu, Feng

    2014-11-01

    Restoring motion-blurred image is the key technologies in the opto-electronic detection system. The imaging sensors such as CCD and infrared imaging sensor, which are mounted on the motion platforms, quickly move together with the platforms of high speed. As a result, the images become blur. The image degradation will cause great trouble for the succeeding jobs such as objects detection, target recognition and tracking. So the motion-blurred images must be restoration before detecting motion targets in the subsequent images. On the demand of the real weapon task, in order to deal with targets in the complex background, this dissertation uses the new theories in the field of image processing and computer vision to research the new technology of motion deblurring and motion detection. The principle content is as follows: 1) When the prior knowledge about degradation function is unknown, the uniform motion blurred images are restored. At first, the blur parameters, including the motion blur extent and direction of PSF(point spread function), are estimated individually in domain of logarithmic frequency. The direction of PSF is calculated by extracting the central light line of the spectrum, and the extent is computed by minimizing the correction between the fourier spectrum of the blurred image and a detecting function. Moreover, in order to remove the strip in the deblurred image, windows technique is employed in the algorithm, which makes the deblurred image clear. 2) According to the principle of infrared image non-uniform exposure, a new restoration model for infrared blurred images is developed. The fitting of infrared image non-uniform exposure curve is performed by experiment data. The blurred images are restored by the fitting curve.

  15. Thermal freeze-out and longitudinally non-uniform collective expansion flow in relativistic heavy ion collisions

    CERN Document Server

    Feng Sheng Qin; LianShouLiu

    2002-01-01

    The non-uniform longitudinal flow model (NUFM) proposed recently is extended to include also the transverse flow. The resulting longitudinally non-uniform collective expansion model (NUCEM) is applied to the calculation of rapidity distribution of kaons, lambdas and protons in relativistic heavy ion collisions at CERN-SPS energies. The model results are compared with the 200 A GeV/c S-S and 158 A GeV/c Pb-Pb collision data. The central dips observed in experiments are reproduced in a natural way. It is found that the depth of the central dip depends on the magnitude of the parameter e and the mass of produced particles, i.e. the non-uniformity of the longitudinal flow which is described by the parameter e determines the depth of the central dip for produced particles. Comparing with one-dimensional non-uniform longitudinal flow model, the rapidity distribution of lighter strange particle kaon also shows a dip due to the effect of transverse flow

  16. Influence of Non-Uniform Magnetic Field on Quantum Teleportation in Heisenberg XY Model

    Institute of Scientific and Technical Information of China (English)

    SHAO Bin; YANG Tie-jian; ZHAO Yue-hong; ZOU Jian

    2007-01-01

    By considering the intrinsic decoherence, the validity of quantum teleportation of a two-qubit 1D Heisenberg XY chain in a non-uniform external magnetic field is studied. The fidelity as the measurement of a possible quantum teleportation is calculated and the effects of the non-uniform magnetic field and the intrinsic decoherence are discussed. It is found that anti-parallel magnetic field is more favorable for teleportation and the fidelity is suppressed by the intrinsic decoherence.

  17. Desynchronization boost by non-uniform coordinated reset stimulation in ensembles of pulse-coupled neurons

    Science.gov (United States)

    Lücken, Leonhard; Yanchuk, Serhiy; Popovych, Oleksandr V.; Tass, Peter A.

    2013-01-01

    Several brain diseases are characterized by abnormal neuronal synchronization. Desynchronization of abnormal neural synchrony is theoretically compelling because of the complex dynamical mechanisms involved. We here present a novel type of coordinated reset (CR) stimulation. CR means to deliver phase resetting stimuli at different neuronal sub-populations sequentially, i.e., at times equidistantly distributed in a stimulation cycle. This uniform timing pattern seems to be intuitive and actually applies to the neural network models used for the study of CR so far. CR resets the population to an unstable cluster state from where it passes through a desynchronized transient, eventually resynchronizing if left unperturbed. In contrast, we show that the optimal stimulation times are non-uniform. Using the model of weakly pulse-coupled neurons with phase response curves, we provide an approach that enables to determine optimal stimulation timing patterns that substantially maximize the desynchronized transient time following the application of CR stimulation. This approach includes an optimization search for clusters in a low-dimensional pulse coupled map. As a consequence, model-specific non-uniformly spaced cluster states cause considerably longer desynchronization transients. Intriguingly, such a desynchronization boost with non-uniform CR stimulation can already be achieved by only slight modifications of the uniform CR timing pattern. Our results suggest that the non-uniformness of the stimulation times can be a medically valuable parameter in the calibration procedure for CR stimulation, where the latter has successfully been used in clinical and pre-clinical studies for the treatment of Parkinson's disease and tinnitus. PMID:23750134

  18. The effects of relativistic and non-local non-linearities on modulational instabilities in non-uniform plasma

    International Nuclear Information System (INIS)

    Mohamed, B.F.; El-Shorbagy, Kh.H.

    2000-01-01

    A general detailed analysis for the nonlinear generation of localized fields due to the existence of a strong pump field inside the non-uniform plasma has been considered. We have taken into account the effects of relativistic and non-local nonlinearities on the structure of plasma resonance region. The nonlinear Schrodinger equation described the localized fields are investigated. Besides, the generalized dispersion relation is obtained to study the modulational instabilities in different cases. Keywords: Wave-plasma interaction, Nonlinear effects, Modulation instabilities

  19. A method for real time detecting of non-uniform magnetic field

    Science.gov (United States)

    Marusenkov, Andriy

    2015-04-01

    The principle of measuring magnetic signatures for observing diverse objects is widely used in Near Surface work (unexploded ordnance (UXO); engineering & environmental; archaeology) and security and vehicle detection systems as well. As a rule, the magnitude of the signals to be measured is much lower than that of the quasi-uniform Earth magnetic field. Usually magnetometers for these purposes contain two or more spatially separated sensors to estimate the full tensor gradient of the magnetic field or, more frequently, only partial gradient components. The both types (scalar and vector) of magnetic sensors could be used. The identity of the scale factors and proper alignment of the sensitivity axes of the vector sensors are very important for deep suppression of the ambient field and detection of weak target signals. As a rule, the periodical calibration procedure is used to keep matching sensors' parameters as close as possible. In the present report we propose the technique for detection magnetic anomalies, which is almost insensitive to imperfect matching of the sensors. This method based on the idea that the difference signals between two sensors are considerably different when the instrument is rotated or moved in uniform and non-uniform fields. Due to the misfit of calibration parameters the difference signal observed at the rotation in the uniform field is similar to the total signal - the sum of the signals of both sensors. Zero change of the difference and total signals is expected, if the instrument moves in the uniform field along a straight line. In contrast, the same move in the non-uniform field produces some response of each of the sensors. In case one measures dB/dx and moves along x direction, the sensors signals is shifted in time with the lag proportional to the distance between sensors and the speed of move. It means that the difference signal looks like derivative of the total signal at move in the non-uniform field. So, using quite simple

  20. Planned studies of charge collection in non-uniformly irradiated Si and GaAs detectors

    International Nuclear Information System (INIS)

    Rosenfeld, A.; Reinhard, M.; Carolan, M.; Kaplan, G.; Lerch, M.; Alexiev, D.

    1995-01-01

    The aim of this project is to study the time and amplitude characteristics of silicon ion-implanted detectors non-uniformly irradiated with fast neutrons in order to predict their radiation behaviour in the LHC and space. It is expected in such detectors increases of the charge deficit due to trapping by large scale traps and transient time increases due to the reduction of the mobility. The theoretical model will be modified to describe the charge kinetics in the electrical field of the detector created by a non uniform space charge distribution. Experimental confirmation techniques are needed to develop non uniform predictable damage of silicon detectors using fast neutron sources (accelerators, reactors) and to study peculiarities of the charge transport in different parts of the detector. In parallel to experimental research will be started the theoretical development of the charge transport model for non-uniform distribution of space charge in the depletion layer (Neff). The model will include the linear distribution of Neff(y) along the detector as well as the change of sign of Neff (conversion from n to p type of silicon) inside the detector

  1. Propagation of coherently combined truncated laser beam arrays with beam distortions in non-Kolmogorov turbulence.

    Science.gov (United States)

    Tao, Rumao; Si, Lei; Ma, Yanxing; Zhou, Pu; Liu, Zejin

    2012-08-10

    The propagation properties of coherently combined truncated laser beam arrays with beam distortions through non-Kolmogorov turbulence are studied in detail both analytically and numerically. The analytical expressions for the average intensity and the beam width of coherently combined truncated laser beam arrays with beam distortions propagating through turbulence are derived based on the combination of statistical optics methods and the extended Huygens-Fresnel principle. The effect of beam distortions, such as amplitude modulation and phase fluctuation, is studied by numerical examples. The numerical results reveal that phase fluctuations have significant influence on the spreading of coherently combined truncated laser beam arrays in non-Kolmogorov turbulence, and the effects of the phase fluctuations can be negligible as long as the phase fluctuations are controlled under a certain level, i.e., a>0.05 for the situation considered in the paper. Furthermore, large phase fluctuations can convert the beam distribution rapidly to a Gaussian form, vary the spreading, weaken the optimum truncation effects, and suppress the dependence of spreading on the parameters of the non-Kolmogorov turbulence.

  2. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    This study investigated the influence of dwell time optimizations on dose uniformity characterized by dose values in dose points and dose non-uniformity ratio (DNR) and analyzed which implant parameters have influence on the DNR. Double-plane breast implants with catheters arranged in triangular pattern were used for the calculations. At a typical breast implant, dose values in dose reference points inside the target volume and volumes enclosed by given isodose surfaces were calculated and compared for non-optimized and optimized implants. The same 6-cm treatment length was used for the comparisons. Using different optimizations plots of dose non-uniformity ratio as a function of catheter separation, source step size, number of catheters, length of active sections were drawn and the minimum DNR values were determined. Optimization resulted in less variation in dose values over dose points through the whole volume and in the central plane only compared to the non-optimized case. At implant configurations consisting of seven catheters with 15-mm separation, 5-mm source step size and various active lengths adapted according to the type of optimization, the no optimization, geometrical (volume mode) and dose point (on dose points and geometry) optimization resulted in similar treatment volumes, but an increased high dose volume was observed due to the optimization. The dose non-uniformity ratio always had the minimum at average dose over dose normalization points, defined in the midpoints between the catheters through the implant volume. The minimum value of DNR depended on catheter separation, source step size, active length and number of catheters. The optimization had only a small influence on DNR. In addition to the reference points in the central plane only, dose points positioned in the whole implant volume can be used for evaluating the dose uniformity of interstitial implants. The dose optimization increases not only the dose uniformity within the implant but

  3. Roi Vaara tähendussõnad

    Index Scriptorium Estoniae

    2003-01-01

    10. II oli Tallinna Kunstihoones soome kunstniku Roi Vaara performance Tallinna Kunstihoone uue juhataja Reiu Tüüri, kuraatorite Andres Härmi ja Reet Varblase inauguratsiooni ning TK interneti lehekülje esitluse puhul. Uue ühtse nimekuju KU autorit Edith Parist autasustati 1934 krooniga

  4. Free vibration analysis of a robotic fish based on a continuous and non-uniform flexible backbone with distributed masses

    Science.gov (United States)

    Coral, W.; Rossi, C.; Curet, O. M.

    2015-12-01

    This paper presents a Differential Quadrature Element Method for free transverse vibration of a robotic fish based on a continuous and non-uniform flexible backbone with distributed masses (fish ribs). The proposed method is based on the theory of a Timoshenko cantilever beam. The effects of the masses (number, magnitude and position) on the value of natural frequencies are investigated. Governing equations, compatibility and boundary conditions are formulated according to the Differential Quadrature rules. The convergence, efficiency and accuracy are compared to other analytical solution proposed in the literature. Moreover, the proposed method has been validate against the physical prototype of a flexible fish backbone. The main advantages of this method, compared to the exact solutions available in the literature are twofold: first, smaller computational cost and second, it allows analysing the free vibration in beams whose section is an arbitrary function, which is normally difficult or even impossible with other analytical methods.

  5. Gravitational Influences on Flame Propagation through Non-Uniform, Premixed Gas Systems

    Science.gov (United States)

    Miller, Fletcher J.; Easton, John; Ross, Howard D.; Marchese, Anthony; Perry, David; Kulis, Michael

    2001-01-01

    Flame propagation through non-uniformly premixed (or layered) gases has importance both in useful combustion systems and in unintentional fires. As summarized previously, non-uniform premixed gas combustion receives scant attention compared to the more usual limiting cases of diffusion or uniformly premixed flames, especially regarding the role gravity plays. This paper summarizes our progress on furthering the knowledge of layered combustion, in which a fuel concentration gradient exists normal to the direction of flame spread. We present experimental and numerical results for flame spread through propanol-air layers formed near the flash point temperature (25 C) or near the stoichiometric temperature (33 C). Both the model and experimental results show that the removal of gravity results in a faster spreading flame, by as much as 80% depending on conditions. This is exactly the opposite effect as that predicted by an earlier model reported. We also found that having a gallery lid results in faster flame spread, an effect more pronounced at normal gravity, demonstrating the importance of enclosure geometry. Also reported here is the beginning of our spectroscopic measurements of fuel vapor.

  6. Determination of non-uniformity correction factors for cylindrical ionization chambers close to 192Ir brachytherapy sources

    International Nuclear Information System (INIS)

    Toelli, H.; Bielajew, A. F.; Mattsson, O.; Sernbo, G.

    1995-01-01

    When ionization chambers are used in brachytherapy dosimetry, the measurements must be corrected for the non-uniformity of the incident photon fluence. The theory for determination of non-uniformity correction factors, developed by Kondo and Randolph (Rad. Res. 1960) assumes that the electron fluence within the air cavity is isotropic and does not take into account material differences in the chamber wall. The theory was extended by Bielajew (PMB 1990) using an anisotropic electron angular fluence in the cavity. In contrast to the theory by Kondo and Randolph, the anisotropic theory predicts a wall material dependence in the non-uniformity correction factors. This work presents experimental determination of non-uniformity correction factors at distances between 10 and 140 mm from an Ir-192 source. The experimental work makes use of a PTW23331-chamber and Farmer-type chambers (NE2571 and NE2581) with different materials in the walls. The results of the experiments agree well with the anisotropic theory. Due to the geometrical shape of the NE-type chambers, it is shown that the full length of the these chambers, 24.1mm, is not an appropriate input parameter when theoretical non-uniformity correction factors are evaluated

  7. Effects of non-uniform embedments on earthquake responses of nuclear reactor building

    International Nuclear Information System (INIS)

    Koyanagi, Y.; Okamoto, S.; Yoshida, K.; Inove, H.

    1989-01-01

    The nuclear reactor buildings have the portion embedded in soil. In the seismic design of such structures, it is essential to consider the effects of the embedment on the earthquake response. Most studies on these effects, however, assume the uniform embedment, i.e. the depth of the embedment is constant, which is convenient for the design and analysis. The behavior of the earthquake response considering the three-dimensional aspects of non-uniform embedment has not been made clear yet. In this paper, the authors evaluate the effects of the non-uniform embedment in an inclined ground surface on the earthquake response of a nuclear reactor building as illustrated. A typical PWR type reactor building is chosen as an analysis structure model. Four different types of embedment are set up for the comparison study. The three-dimensional analysis is carried out considering the geometry of embedment

  8. The first experience with LHC beam gas ionization monitor

    CERN Document Server

    Sapinski, M; Dehning, B; Guerrero, A; Patecki, M; Versteegen, R

    2012-01-01

    The Beam Gas Ionization Monitors (BGI) are used to measure beam emittance on LHC. This paper describes the detectors and their operation and discusses the issues met during the commissioning. It also discusses the various calibration procedures used to correct for non-uniformity of Multi-Channel plates and to correct the beam size for effects affecting the electron trajectory after ionization.

  9. Modeling of parallel-plate regenerators with non-uniform plate distributions

    DEFF Research Database (Denmark)

    Jensen, Jesper Buch; Engelbrecht, Kurt; Bahl, Christian Robert Haffenden

    2010-01-01

    plate spacing distributions are presented in order to understand the impact of spacing non-uniformity. Simulations of more realistic distributions where the plate spacings follow normal distributions are then discussed in order to describe the deviation of the performance of a regenerator relative...

  10. An efficient shutter-less non-uniformity correction method for infrared focal plane arrays

    Science.gov (United States)

    Huang, Xiyan; Sui, Xiubao; Zhao, Yao

    2017-02-01

    The non-uniformity response in infrared focal plane array (IRFPA) detectors has a bad effect on images with fixed pattern noise. At present, it is common to use shutter to prevent from radiation of target and to update the parameters of non-uniformity correction in the infrared imaging system. The use of shutter causes "freezing" image. And inevitably, there exists the problems of the instability and reliability of system, power consumption, and concealment of infrared detection. In this paper, we present an efficient shutter-less non-uniformity correction (NUC) method for infrared focal plane arrays. The infrared imaging system can use the data gaining in thermostat to calculate the incident infrared radiation by shell real-timely. And the primary output of detector except the shell radiation can be corrected by the gain coefficient. This method has been tested in real infrared imaging system, reaching high correction level, reducing fixed pattern noise, adapting wide temperature range.

  11. Many-junction photovoltaic device performance under non-uniform high-concentration illumination

    Science.gov (United States)

    Valdivia, Christopher E.; Wilkins, Matthew M.; Chahal, Sanmeet S.; Proulx, Francine; Provost, Philippe-Olivier; Masson, Denis P.; Fafard, Simon; Hinzer, Karin

    2017-09-01

    A parameterized 3D distributed circuit model was developed to calculate the performance of III-V solar cells and photonic power converters (PPC) with a variable number of epitaxial vertically-stacked pn junctions. PPC devices are designed with many pn junctions to realize higher voltages and to operate under non-uniform illumination profiles from a laser or LED. Performance impacts of non-uniform illumination were greatly reduced with increasing number of junctions, with simulations comparing PPC devices with 3 to 20 junctions. Experimental results using Azastra Opto's 12- and 20-junction PPC illuminated by an 845 nm diode laser show high performance even with a small gap between the PPC and optical fiber output, until the local tunnel junction limit is reached.

  12. Non-uniformity of phase structure in immiscible polymer blends

    Czech Academy of Sciences Publication Activity Database

    Fortelný, Ivan; Lapčíková, Monika; Lednický, František; Starý, Zdeněk; Kruliš, Zdeněk

    2008-01-01

    Roč. 48, č. 3 (2008), s. 564-571 ISSN 0032-3888 R&D Projects: GA ČR GA106/06/0729; GA ČR GA106/06/0761 Institutional research plan: CEZ:AV0Z40500505 Keywords : polymer blends * melt mixing * non-uniform morphology Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.245, year: 2008

  13. A practical attenuation compensation method for cone beam spect

    International Nuclear Information System (INIS)

    Manglos, S.H.; Jaszczak, R.J.; Floyd, C.E.; Greer, K.L.; Coleman, R.E.

    1987-01-01

    An algorithm for attenuation compensation of cone beam SPECT images has been developed and implemented. The algorithm is based on a multiplicative post-processing method previously used for parallel and fan beam geometries. This method computes the compensation from the estimated average attenuation of photons originating from each image pixel. In the present development, a uniform attenuation coefficient inside of the body contour is assumed, although the method could be extended to include a non-uniform attenuation map. The algorithm is tested with experimental projections of a phantom obtained using a cone beam collimator. Profiles through the reconstructed images are presented as a quantitative test of the improvement due to the compensation. The algorithm provides adequate compensation for attenuation in a simple uniform cylindrical phantom, and the computational time is short compared to that expected for iterative reconstruction techniques. Also observed are image distortions in some reconstructed slices when the source distribution extends beyond the edge of the cone beam axial field-of-view

  14. Prototype heel effect compensation filter for cone-beam CT

    International Nuclear Information System (INIS)

    Mori, Shinichiro; Endo, Masahiro; Nishizawa, Kanae; Ohno, Mari; Miyazaki, Hiroaki; Tsujita, Kazuhiko; Saito, Yasuo

    2005-01-01

    The prototype cone-beam CT (CBCT) has a larger beam width than the conventional multi-detector row CT (MDCT). This causes a non-uniform angular distribution of the x-ray beam intensity known as the heel effect. Scan conditions for CBCT tube current are adjusted on the anode side to obtain an acceptable clinical image quality. However, as the dose is greater on the cathode side than on the anode side, the signal-to-noise ratio on the cathode side is excessively high, resulting in an unnecessary dose amount. To compensate for the heel effect, we developed a heel effect compensation (HEC) filter. The HEC filter rendered the dose distribution uniform and reduced the dose by an average of 25% for free air and by 20% for CTDI phantoms compared to doses with the conventional filter. In addition, its effect in rendering the effective energy uniform resulted in an improvement in image quality. This new HEC filter may be useful in cone-beam CT studies. (note)

  15. The demagnetizing field of a non-uniform rectangular prism

    DEFF Research Database (Denmark)

    Smith, Anders; Nielsen, Kaspar Kirstein; Christensen, Dennis

    2010-01-01

    The effect of demagnetization on the magnetic properties of a rectangular ferromagnetic prism under non-uniform conditions is investigated. A numerical model for solving the spatially varying internal magnetic field is developed, validated and applied to relevant cases. The demagnetizing field...... is solved by an analytical calculation and the coupling between applied field, the demagnetization tensor field and spatially varying temperature is solved through iteration. We show that the demagnetizing field is of great importance in many cases and that it is necessary to take into account the non...

  16. Deep convolutional neural networks for dense non-uniform motion deblurring

    CSIR Research Space (South Africa)

    Cronje, J

    2015-11-01

    Full Text Available to form a dense non-uniform motion estimation map. Furthermore, a second CNN is trained to perform deblurring given a blurry image patch and the estimated motion vector. Combining the two trained networks result in a deep learning approach that can enhance...

  17. SU-F-J-19: Robust Region-Of-Interest (ROI) for Consistent Registration On Deteriorated Surface Images

    Energy Technology Data Exchange (ETDEWEB)

    Kang, H; Malin, M; Chmura, S; Hasan, Y; Al-Hallaq, H [The Department of Radiation and Cellular Oncology, The University of Chicago Medicine, Chicago, IL (United States)

    2016-06-15

    Purpose: For African-American patients receiving breast radiotherapy with a bolus, skin darkening can affect the surface visualization when using optical imaging for daily positioning and gating at deep-inspiration breath holds (DIBH). Our goal is to identify a region-of-interest (ROI) that is robust against deteriorating surface image quality due to skin darkening. Methods: We study four patients whose post-mastectomy surfaces are imaged daily with AlignRT (VisionRT, UK) for DIBH radiotherapy and whose surface image quality is degraded toward the end of treatment. To simulate the effects of skin darkening, surfaces from the first ten fractions of each patient are systematically degraded by 25–35%, 40–50% and 65–75% of the total area of the clinically used ROI-ipsilateral-chestwall. The degraded surfaces are registered to the reference surface in six degrees-of-freedom. To identify a robust ROI, three additional reference ROIsROI-chest+abdomen, ROI-bilateral-chest and ROI-extended-ipsilateral-chestwall are created and registered to the degraded surfaces. Differences in registration using these ROIs are compared to that using ROI-ipsilateral-chestwall. Results: For three patients, the deviations in the registrations to ROI-ipsilateral-chestwall are > 2.0, 3.1 and 7.9mm on average for 25–35%, 40–50% and 65–75% degraded surfaces, respectively. Rotational deviations reach 11.1° in pitch. For the last patient, registration is consistent to within 2.6mm even on the 65–75% degraded surfaces, possibly because the surface topography has more distinct features. For ROI-bilateral-chest and ROI-extended-ipsilateral-chest registrations deviate in a similar pattern. However, registration on ROI-chest+abdomen is robust to deteriorating image qualities to within 4.2mm for all four patients. Conclusion: Registration deviations using ROI-ipsilateral-chestwall can reach 9.8mm on the 40–50% degraded surfaces. Caution is required when using AlignRT for patients

  18. Selective exfoliation of single-layer graphene from non-uniform graphene grown on Cu

    International Nuclear Information System (INIS)

    Lim, Jae-Young; Lee, Jae-Hyun; Jang, Hyeon-Sik; Whang, Dongmok; Joo, Won-Jae; Hwang, SungWoo

    2015-01-01

    Graphene growth on a copper surface via metal-catalyzed chemical vapor deposition has several advantages in terms of providing high-quality graphene with the potential for scale-up, but the product is usually inhomogeneous due to the inability to control the graphene layer growth. The non-uniform regions strongly affect the reliability of the graphene in practical electronic applications. Herein, we report a novel graphene transfer method that allows for the selective exfoliation of single-layer graphene from non-uniform graphene grown on a Cu foil. Differences in the interlayer bonding energy are exploited to mechanically separate only the top single-layer graphene and transfer this to an arbitrary substrate. The dry-transferred single-layer graphene showed electrical characteristics that were more uniform than those of graphene transferred using conventional wet-etching transfer steps. (paper)

  19. The evaluation of the automatic setting of ROI to SPECT measuring cerebral blood flow

    International Nuclear Information System (INIS)

    Mizuno, Hiroshi; Takahashi, Masaaki; Yoshioka, Katsunori

    2007-01-01

    It has been pointed out that the manual settings of region of interest (ROI) to the single-photon-emission-computed-tomography (SPECT) slice lacked objectivity when the fixed quantity value of regional cerebral blood flow (rCBF) was measured previously. Therefore, we jointly developed software Brain ROI'' with Daiichi Radioisotope Laboratories, Ltd. (DRL) that normalized an individual brain to a standard brain template by using Statistical Parametric Mapping 2 (SPM 2) of easy Z-score Imaging System ver. 3.0 (eZIS Ver. 3.0), and, ROI template was set to a specific slice. In this paper, we evaluated the accuracy of this software with ROI template that we made the useful size of the shape, in some clinical samples. As a result, the method of the automatic setting of ROI was the objectively. However, we thought that we should use the shape of ROI template without an influence of Brain atrophy. Moreover, we should see Normalizing individual brain and confirm the accuracy of normalization. When failing in normalization, we should partially correct ROI or set all by the manual operation of the operator. However, it was thought that this software was useful if the tendency was understood because the failure example was few. (author)

  20. Non-destructive beam profile monitor at HIMAC

    International Nuclear Information System (INIS)

    Sato, S.; Araki, N.; Hosaka, M.

    1995-01-01

    Non-destructive profile monitors (NDPM), based on micro-channel plate (MCP), have been developed and installed in both the synchrotron ring and high-energy beam transport (HEBT) line at HIMAC. Beam test using these monitors have been carried out since April of 1995 to investigate a change of vertical beam size in synchrotron and a possibility of observing beam with high energy by one pass. In this paper the measurement system is mainly reported, and the preliminary results are also briefly presented. (author)

  1. Negative optical spin torque wrench of a non-diffracting non-paraxial fractional Bessel vortex beam

    Science.gov (United States)

    Mitri, F. G.

    2016-10-01

    An absorptive Rayleigh dielectric sphere in a non-diffracting non-paraxial fractional Bessel vortex beam experiences a spin torque. The axial and transverse radiation spin torque components are evaluated in the dipole approximation using the radiative correction of the electric field. Particular emphasis is given on the polarization as well as changing the topological charge α and the half-cone angle of the beam. When α is zero, the axial spin torque component vanishes. However, when α becomes a real positive number, the vortex beam induces left-handed (negative) axial spin torque as the sphere shifts off-axially from the center of the beam. The results show that a non-diffracting non-paraxial fractional Bessel vortex beam is capable of inducing a spin reversal of an absorptive Rayleigh sphere placed arbitrarily in its path. Potential applications are yet to be explored in particle manipulation, rotation in optical tweezers, optical tractor beams, and the design of optically-engineered metamaterials to name a few areas.

  2. An FDK-like cone-beam SPECT reconstruction algorithm for non-uniform attenuated projections acquired using a circular trajectory

    International Nuclear Information System (INIS)

    Huang, Q; Zeng, G L; You, J; Gullberg, G T

    2005-01-01

    In this paper, Novikov's inversion formula of the attenuated two-dimensional (2D) Radon transform is applied to the reconstruction of attenuated fan-beam projections acquired with equal detector spacing and of attenuated cone-beam projections acquired with a flat planar detector and circular trajectory. The derivation of the fan-beam algorithm is obtained by transformation from parallel-beam coordinates to fan-beam coordinates. The cone-beam reconstruction algorithm is an extension of the fan-beam reconstruction algorithm using Feldkamp-Davis-Kress's (FDK) method. Computer simulations indicate that the algorithm is efficient and is accurate in reconstructing slices close to the central slice of the cone-beam orbit plane. When the attenuation map is set to zero the implementation is equivalent to the FDK method. Reconstructed images are also shown for noise corrupted projections

  3. An Improved Rate-Transient Analysis Model of Multi-Fractured Horizontal Wells with Non-Uniform Hydraulic Fracture Properties

    Directory of Open Access Journals (Sweden)

    Youwei He

    2018-02-01

    Full Text Available Although technical advances in hydraulically fracturing and drilling enable commercial production from tight reservoirs, oil/gas recovery remains at a low level. Due to the technical and economic limitations of well-testing operations in tight reservoirs, rate-transient analysis (RTA has become a more attractive option. However, current RTA models hardly consider the effect of the non-uniform production on rate decline behaviors. In fact, PLT results demonstrate that production profile is non-uniform. To fill this gap, this paper presents an improved RTA model of multi-fractured horizontal wells (MFHWs to investigate the effects of non-uniform properties of hydraulic fractures (production of fractures, fracture half-length, number of fractures, fracture conductivity, and vertical permeability on rate transient behaviors through the diagnostic type curves. Results indicate obvious differences on the rate decline curves among the type curves of uniform properties of fractures (UPF and non-uniform properties of fractures (NPF. The use of dimensionless production integral derivative curve magnifies the differences so that we can diagnose the phenomenon of non-uniform production. Therefore, it’s significant to incorporate the effects of NPF into the RDA models of MFHWs, and the model proposed in this paper enables us to better evaluate well performance based on long-term production data.

  4. SU-E-T-542: Measurement of Internal Neutrons for Uniform Scanning Proton Beams

    Energy Technology Data Exchange (ETDEWEB)

    Islam, M; Ahmad, S [University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma (United States); Zheng, Y; Rana, S [Procure Proton Therapy Center, Oklahoma City, OK (United States); Collums, T [University of Iowa Hospitals and Clinics, Iowa City, IA (United States); Monsoon, J; Benton, E [Oklahoma State University, Stillwater, OK (United States)

    2015-06-15

    Purpose: In proton radiotherapy, the production of neutrons is a wellknown problem since neutron exposure can lead to increased risk of secondary cancers later in the patient’s lifetime. The assessment of neutron exposure is, therefore, important for the overall quality of proton radiotherapy. This study investigates the secondary neutrons created inside the patient from uniform scanning proton beams. Methods: Dose equivalent due to secondary neutrons was measured outside the primary field as a function of distance from beam isocenter at three different angles, 45, 90 and 135 degree, relative to beam axis. Plastic track nuclear detector (CR-39 PNTD) was used for the measurement of neutron dose. Two experimental configurations, in-air and cylindrical-phantom, were designed. In a cylindrical-phantom configuration, a cylindrical phantom of 5.5 cm diameter and 35 cm long was placed along the beam direction and in an in-air configuration, no phantom was used. All the detectors were placed at nearly identical locations in both configurations. Three proton beams of range 5 cm, 18 cm, and 32 cm with 4 cm modulation width and a 5 cm diameter aperture were used. The contribution from internal neutrons was estimated from the differences in measured dose equivalent between in-air and cylindrical-phantom configurations at respective locations. Results: The measured ratio of neutron dose equivalent to the primary proton dose (H/D) dropped off with distance and ranged from 27 to 0.3 mSv/Gy. The contribution of internal neutrons near the treatment field edge was found to be up to 64 % of the total neutron exposure. As the distance from the field edge became larger, the external neutrons from the nozzle appear to dominate and the internal neutrons became less prominent. Conclusion: This study suggests that the contribution of internal neutrons could be significant to the total neutron dose equivalent.

  5. Region-of-interest reconstruction for a cone-beam dental CT with a circular trajectory

    International Nuclear Information System (INIS)

    Hu, Zhanli; Zou, Jing; Gui, Jianbao; Zheng, Hairong; Xia, Dan

    2013-01-01

    Dental CT is the most appropriate and accurate device for preoperative evaluation of dental implantation. It can demonstrate the quantity of bone in three dimensions (3D), the location of important adjacent anatomic structures and the quality of available bone with minimal geometric distortion. Nevertheless, with the rapid increase of dental CT examinations, we are facing the problem of dose reduction without loss of image quality. In this work, backprojection-filtration (BPF) and Feldkamp–Davis–Kress (FDK) algorithm was applied to reconstruct the 3D full image and region-of-interest (ROI) image from complete and truncated circular cone-beam data respectively by computer-simulation. In addition, the BPF algorithm was evaluated based on the 3D ROI-image reconstruction from real data, which was acquired from our developed circular cone-beam prototype dental CT system. The results demonstrated that the ROI-image quality reconstructed from truncated data using the BPF algorithm was comparable to that reconstructed from complete data. The FDK algorithm, however, created artifacts while reconstructing ROI-image. Thus it can be seen, for circular cone-beam dental CT, reducing scanning angular range of the BPF algorithm used for ROI-image reconstruction are helpful for reducing the radiation dose and scanning time. Finally, an analytical method was developed for estimation of the ROI projection area on the detector before CT scanning, which would help doctors to roughly estimate the total radiation dose before the CT examination. -- Highlights: ► BPF algorithm was applied by using dental CT for the first time. ► A method was developed for estimation of projection region before CT scanning. ► Roughly predict the total radiation dose before CT scans. ► Potential reduce imaging radiation dose, scatter, and scanning time

  6. Smoothing and instability with magnetic field in a non-uniformly laser-irradiated planar target

    International Nuclear Information System (INIS)

    Bell, A.R.; Epperlein, E.M.

    1986-01-01

    Calculations are presented of the magneto-hydrodynamic response of a planar target to non-uniformities in energy deposition by a laser. The amplitude of the non-uniformities are assumed small and the equations are linearised in small perturbations about the solution for steady planar ablation driven by uniform laser energy deposition. The grad(n)xgrad(T) magnetic field source is included, along with Nernst convection and the Righi-Leduc heat flow. The magnetic field is shown to give a small increase in smoothing. A source term for magnetic field is included to simulate the effects of the Weibel instability. The instability is not strong enough to overcome the smoothing processes under the present assumptions. (author)

  7. Temperature dependence of o-Ps annihilation lifetime in non-uniform cylindrical pores in comparison with ETE model

    Energy Technology Data Exchange (ETDEWEB)

    Khaghani, Morteza, E-mail: m.khaghani@pgs.usb.ac.ir; Mehmandoost-Khajeh-Dad, Ali Akbar, E-mail: mehmandoost@phys.usb.ac.ir

    2017-04-01

    Highlights: • Using the well known multi-physics program COMSOL calculating o-Ps annihilation lifetime in complex geometries. • Investigation of shape non-uniformity of cylindrical pores on o-Ps annihilation lifetime. • Verifying temperature dependency of o-Ps lifetime in non-uniform cylindrical pores. • Suggesting PALS at low temperature as a method to verify pore uniformity in porous material. - Abstract: Ortho-positronium (o-Ps) annihilation lifetime was calculated in non-uniform cylinder-shaped pores by solving Schrodinger equation using a well-known multi-physics program called COMSOL. The o-Ps annihilation lifetime variation in terms of temperature was calculated on the basis of ETE model via a numerical method. The COMSOL simulations indicate that as long as the pore is uniform cylinder-shaped, the results agree with those of two-dimensional ETE model, whereas deformations in the cylinder shape (indentation or protrusion) change the temperature behavior of ETE model and, thereby, higher values are predicted for o-Ps lifetime in the pore at lower temperatures. The geometry of the non-uniform cylinder-shaped pores, which is accompanied by empirical evidence, can be used for the analysis of empirical results obtained from positron lifetime spectroscopy in different temperatures.

  8. A direct ROI quantification method for inherent PVE correction: accuracy assessment in striatal SPECT measurements

    Energy Technology Data Exchange (ETDEWEB)

    Vanzi, Eleonora; De Cristofaro, Maria T.; Sotgia, Barbara; Mascalchi, Mario; Formiconi, Andreas R. [University of Florence, Clinical Pathophysiology, Florence (Italy); Ramat, Silvia [University of Florence, Neurological and Psychiatric Sciences, Florence (Italy)

    2007-09-15

    The clinical potential of striatal imaging with dopamine transporter (DAT) SPECT tracers is hampered by the limited capability to recover activity concentration ratios due to partial volume effects (PVE). We evaluated the accuracy of a least squares method that allows retrieval of activity in regions of interest directly from projections (LS-ROI). An Alderson striatal phantom was filled with striatal to background ratios of 6:1, 9:1 and 28:1; the striatal and background ROIs were drawn on a coregistered X-ray CT of the phantom. The activity ratios of these ROIs were derived both with the LS-ROI method and with conventional SPECT EM reconstruction (EM-SPECT). Moreover, the two methods were compared in seven patients with motor symptoms who were examined with N-3-fluoropropyl-2-{beta}-carboxymethoxy-3-{beta}-(4-iodophenyl) (FP-CIT) SPECT, calculating the binding potential (BP). In the phantom study, the activity ratios obtained with EM-SPECT were 3.5, 5.3 and 17.0, respectively, whereas the LS-ROI method resulted in ratios of 6.2, 9.0 and 27.3, respectively. With the LS-ROI method, the BP in the seven patients was approximately 60% higher than with EM-SPECT; a linear correlation between the LS-ROI and the EM estimates was found (r = 0.98, p = 0.03). The LS-ROI PVE correction capability is mainly due to the fact that the ill-conditioning of the LS-ROI approach is lower than that of the EM-SPECT one. The LS-ROI seems to be feasible and accurate in the examination of the dopaminergic system. This approach can be fruitful in monitoring of disease progression and in clinical trials of dopaminergic drugs. (orig.)

  9. Negative optical spin torque wrench of a non-diffracting non-paraxial fractional Bessel vortex beam

    International Nuclear Information System (INIS)

    Mitri, F.G.

    2016-01-01

    An absorptive Rayleigh dielectric sphere in a non-diffracting non-paraxial fractional Bessel vortex beam experiences a spin torque. The axial and transverse radiation spin torque components are evaluated in the dipole approximation using the radiative correction of the electric field. Particular emphasis is given on the polarization as well as changing the topological charge α and the half-cone angle of the beam. When α is zero, the axial spin torque component vanishes. However, when α becomes a real positive number, the vortex beam induces left-handed (negative) axial spin torque as the sphere shifts off-axially from the center of the beam. The results show that a non-diffracting non-paraxial fractional Bessel vortex beam is capable of inducing a spin reversal of an absorptive Rayleigh sphere placed arbitrarily in its path. Potential applications are yet to be explored in particle manipulation, rotation in optical tweezers, optical tractor beams, and the design of optically-engineered metamaterials to name a few areas. - Highlights: • Optical nondiffracting nonparaxial fractional Bessel vortex beam is considered. • Negative spin torque on an absorptive dielectric Rayleigh sphere is predicted numerically. • Negative spin torque occurs as the sphere departs from the center of the beam.

  10. Effect of scatter and attenuation correction in ROI analysis of brain perfusion scintigraphy. Phantom experiment and clinical study in patients with unilateral cerebrovascular disease

    Energy Technology Data Exchange (ETDEWEB)

    Bai, J. [Keio Univ., Tokyo (Japan). 21st Century Center of Excellence Program; Hashimoto, J.; Kubo, A. [Keio Univ., Tokyo (Japan). Dept. of Radiology; Ogawa, K. [Hosei Univ., Tokyo (Japan). Dept. of Electronic Informatics; Fukunaga, A.; Onozuka, S. [Keio Univ., Tokyo (Japan). Dept. of Neurosurgery

    2007-07-01

    The aim of this study was to evaluate the effect of scatter and attenuation correction in region of interest (ROI) analysis of brain perfusion single-photon emission tomography (SPECT), and to assess the influence of selecting the reference area on the calculation of lesion-to-reference count ratios. Patients, methods: Data were collected from a brain phantom and ten patients with unilateral internal carotid artery stenosis. A simultaneous emission and transmission scan was performed after injecting {sup 123}I-iodoamphetamine. We reconstructed three SPECT images from common projection data: with scatter correction and nonuniform attenuation correction, with scatter correction and uniform attenuation correction, and with uniform attenuation correction applied to data without scatter correction. Regional count ratios were calculated by using four different reference areas (contralateral intact side, ipsilateral cerebellum, whole brain and hemisphere). Results: Scatter correction improved the accuracy of measuring the count ratios in the phantom experiment. It also yielded marked difference in the count ratio in the clinical study when using the cerebellum, whole brain or hemisphere as the reference. Difference between nonuniform and uniform attenuation correction was not significant in the phantom and clinical studies except when the cerebellar reference was used. Calculation of the lesion-to-normal count ratios referring the same site in the contralateral hemisphere was not dependent on the use of scatter correction or transmission scan-based attenuation correction. Conclusion: Scatter correction was indispensable for accurate measurement in most of the ROI analyses. Nonuniform attenuation correction is not necessary when using the reference area other than the cerebellum. (orig.)

  11. The impact of non-uniform channel layer growth on device characteristics in state of the Art Si/SiGe/Si p-metal oxide semiconductor field effect transistors

    International Nuclear Information System (INIS)

    Chang, A.C.K.; Ross, I.M.; Norris, D.J.; Cullis, A.G.; Tang, Y.T.; Cerrina, C.; Evans, A.G.R.

    2006-01-01

    In this study we have highlighted the effect of non-uniform channel layer growth by the direct correlation of the microstructure and electrical characteristics in state-of-the-art pseudomorphic Si/SiGe p-channel metal oxide semiconductor field effect transistor devices fabricated on Si. Two nominally identical sets of devices from adjacent locations of the same wafer were found to have radically different distributions in gate threshold voltages. Due to the close proximity and narrow gate length of the devices, focused ion beam milling was used to prepare a number of thin cross-sections from each of the two regions for subsequent analysis using transmission electron microscopy. It was found that devices from the region giving a very narrow range of gate threshold voltages exhibited a uniform microstructure in general agreement with the intended growth parameters. However, in the second region, which showed a large spread in the gate threshold voltages, profound anomalies in the microstructure were observed. These anomalies consisted of fluctuations in the quality and thickness of the SiGe strained layers. The non-uniform growth of the strained SiGe layer clearly accounted for the poorly controlled threshold voltages of these devices. The results emphasize the importance of good layer growth uniformity to ensure optimum device yield

  12. Adding muscle where you need it: non-uniform hypertrophy patterns in elite sprinters.

    Science.gov (United States)

    Handsfield, G G; Knaus, K R; Fiorentino, N M; Meyer, C H; Hart, J M; Blemker, S S

    2017-10-01

    Sprint runners achieve much higher gait velocities and accelerations than average humans, due in part to large forces generated by their lower limb muscles. Various factors have been explored in the past to understand sprint biomechanics, but the distribution of muscle volumes in the lower limb has not been investigated in elite sprinters. In this study, we used non-Cartesian MRI to determine muscle sizes in vivo in a group of 15 NCAA Division I sprinters. Normalizing muscle sizes by body size, we compared sprinter muscles to non-sprinter muscles, calculated Z-scores to determine non-uniformly large muscles in sprinters, assessed bilateral symmetry, and assessed gender differences in sprinters' muscles. While limb musculature per height-mass was 22% greater in sprinters than in non-sprinters, individual muscles were not all uniformly larger. Hip- and knee-crossing muscles were significantly larger among sprinters (mean difference: 30%, range: 19-54%) but only one ankle-crossing muscle was significantly larger (tibialis posterior, 28%). Population-wide asymmetry was not significant in the sprint population but individual muscle asymmetries exceeded 15%. Gender differences in normalized muscle sizes were not significant. The results of this study suggest that non-uniform hypertrophy patterns, particularly large hip and knee flexors and extensors, are advantageous for fast sprinting. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Long GRBs sources population non-uniformity

    Science.gov (United States)

    Arkhangelskaja, Irene

    Long GRBs observed in the very wide energy band. It is possible to separate two subsets of GRBs with high energy component (E > 500 MeV) presence. First type events energy spectra in low and high energy intervals are similar (as for GRB 021008) and described by Band, power law or broken power law models look like to usual bursts without emission in tens MeV region. For example, Band spectrum of GRB080916C covering 6 orders of magnitude. Second ones contain new additional high energy spectral component (for example, GRB 050525B and GRB 090902B). Both types of GRBs observed since CGRO mission beginning. The low energy precursors existence are typical for all types bursts. Both types of bursts temporal profiles can be similar in the various energy regions during some events or different in other cases. The absence of hard to soft evolution in low energy band and (or) presence of high energy precursors for some events are the special features of second class of GRBs by the results of preliminary data analysis and this facts gives opportunities to suppose differences between these two GRBs subsets sources. Also the results of long GRB redshifts distribution analysis have shown its shape contradiction to uniform population objects one for our Metagalaxy to both total and various redshifts definition methods GRBs sources samples. These evidences allow making preliminary conclusion about non-uniformity of long GRBs sources population.

  14. A two-dimensional finite element model of front surface current flow in cells under non-uniform, concentrated illumination

    Energy Technology Data Exchange (ETDEWEB)

    Mellor, A.; Domenech-Garret, J.L.; Chemisana, D.; Rosell, J.I. [Departament de Medi Ambient i C.S., University of Lleida, Av. Alcalde Rovira Roure 191, E25198 (Spain)

    2009-09-15

    A two-dimensional finite element model of current flow in the front surface of a PV cell is presented. In order to validate this model we perform an experimental test. Later, particular attention is paid to the effects of non-uniform illumination in the finger direction which is typical in a linear concentrator system. Fill factor, open circuit voltage and efficiency are shown to decrease with increasing degree of non-uniform illumination. It is shown that these detrimental effects can be mitigated significantly by reoptimization of the number of front surface metallization fingers to suit the degree of non-uniformity. The behavior of current flow in the front surface of a cell operating at open circuit voltage under non-uniform illumination is discussed in detail. (author)

  15. Acoustic non-diffracting Airy beam

    International Nuclear Information System (INIS)

    Lin, Zhou; Guo, Xiasheng; Tu, Juan; Ma, Qingyu; Wu, Junru; Zhang, Dong

    2015-01-01

    The acoustic non-diffracting Airy beam as its optical counterpart has unique features of self-bending and self-healing. The complexity of most current designs handicaps its applications. A simple design of an acoustic source capable of generating multi-frequency and broad-band acoustic Airy beam has been theoretically demonstrated by numerical simulations. In the design, a piston transducer is corrugated to induce spatial phase variation for transducing the Airy function. The piston's surface is grooved in a pattern that the width of each groove corresponds to the half wavelength of Airy function. The resulted frequency characteristics and its dependence on the size of the piston source are also discussed. This simple design may promote the wide applications of acoustic Airy beam particularly in the field of medical ultrasound

  16. CSR Impedance for Non-Ultrarelativistic Beams

    International Nuclear Information System (INIS)

    Li, Rui; Tsai, Cheng Y.

    2015-09-01

    For the analysis of the coherent synchrotron radiation (CSR)-induced microbunching gain in the low energy regime, such as when a high-brightness electron beam is transported through a low-energy merger in an energy-recovery linac (ERL) design, it is necessary to extend the CSR impedance expression in the ultrarelativistic limit to the non-ultrarelativistic regime. This paper presents our analysis of CSR impedance for general beam energies.

  17. Exact Finite Differences. The Derivative on Non Uniformly Spaced Partitions

    Directory of Open Access Journals (Sweden)

    Armando Martínez-Pérez

    2017-10-01

    Full Text Available We define a finite-differences derivative operation, on a non uniformly spaced partition, which has the exponential function as an exact eigenvector. We discuss some properties of this operator and we propose a definition for the components of a finite-differences momentum operator. This allows us to perform exact discrete calculations.

  18. Measurement of fuel importance distribution in non-uniformly distributed fuel systems

    International Nuclear Information System (INIS)

    Yamane, Yoshihiro; Hirano, Yasushi; Yasui, Hazime; Izima, Kazunori; Shiroya, Seiji; Kobayashi, Keiji.

    1995-01-01

    A reactivity effect due to a spatial variation of nuclear fuel concentration is an important problem for nuclear criticality safety in a reprocessing plant. As a theory estimating this reactivity effect, the Goertzel and fuel importance theories are well known. It has been shown that the Goertzel's theory is valid in the range of our experiments based on measurements of reactivity effect and thermal neutron flux in non-uniformly distributed fuel systems. On the other hand, there have been no reports concerning systematic experimental studies on the flatness of fuel importance which is a more general index than the Goertzel's theory. It is derived from the perturbation theory that the fuel importance is proportional to the reactivity change resulting from a change of small amount of fuel mass. Using a uniform and three kinds of nonuniform fuel systems consisting of 93.2% enriched uranium plates and polyethylene plates, the fuel importance distributions were measured. As a result, it was found experimentally that the fuel importance distribution became flat, as its reactivity effect became large. Therefore it was concluded that the flatness of fuel importance distribution is the useful index for estimating reactivity effect of non-uniformly distributed fuel system. (author)

  19. Test stand for non-uniformity correction of microbolometer focal plane arrays used in thermal cameras

    Science.gov (United States)

    Krupiński, Michał; Bareła, Jaroslaw; Firmanty, Krzysztof; Kastek, Mariusz

    2013-10-01

    Uneven response of particular detectors (pixels) to the same incident power of infrared radiation is an inherent feature of microbolometer focal plane arrays. As a result an image degradation occurs, known as Fixed Pattern Noise (FPN), which distorts the thermal representation of an observed scene and impairs the parameters of a thermal camera. In order to compensate such non-uniformity, several NUC correction methods are applied in digital data processing modules implemented in thermal cameras. Coefficients required to perform the non-uniformity correction procedure (NUC coefficients) are determined by calibrating the camera against uniform radiation sources (blackbodies). Non-uniformity correction is performed in a digital processing unit in order to remove FPN pattern in the registered thermal images. Relevant correction coefficients are calculated on the basis of recorded detector responses to several values of radiant flux emitted from reference IR radiation sources (blackbodies). The measurement of correction coefficients requires specialized setup, in which uniform, extended radiation sources with high temperature stability are one of key elements. Measurement stand for NUC correction developed in Institute of Optoelectronics, MUT, comprises two integrated extended blackbodies with the following specifications: area 200×200 mm, stabilized absolute temperature range +15 °C÷100 °C, and uniformity of temperature distribution across entire surface +/-0.014 °C. Test stand, method used for the measurement of NUC coefficients and the results obtained during the measurements conducted on a prototype thermal camera will be presented in the paper.

  20. Prevention of Bridge Scour with Non-uniform Circular Piers Plane under Steady Flows

    Science.gov (United States)

    Chen, Hsing-Ting; Wang, Chuan-Yi

    2017-04-01

    River bed scour and deposit variation extremely severe because of most of rivers are steep and rapid flows, and river discharge extremely unstable and highly unsteady during different seasons in Taiwan. In addition to the obstruction of piers foundation, it causes local scour and threatens the safety of bridges. In the past, riprap, wire gabion or wrap pier works were adopted as the protections of piers foundation, but there were no effectual outcomes. The events of break off piers still happen sometimes. For example, typhoon Kalmaegi (2008) and Morakot (2009) caused heavy damages on Ho-Fon bridge in the Da-jia river and Shuang-Yuan bridge in the Kao-Ping river, respectively. Accordingly, to understand the piers scour system and propose an appropriate protection of piers foundation becomes an important topic for this study currently. This research improves the protection works of the existing uniform bridge pier (diameter D) to ensure the safety of the bridge. The non-uniform plane of circular piers (diameter D*) are placed on the top of a bridge pier foundation to reduce the down flow impacting energy and scour by its' surface roughness characteristics. This study utilize hydraulic models to simulate local scour depth and scour depth change with time for non-uniform pier diameter ratio D/D* of 0.3,0.4,0.5,0.6,0.7 and 0.8, and different type pier and initial bed level (Y) relative under the foundation top elevation under steady flows of V/Vc=0.95,0.80 and 0.65. The research results show that the scour depth increases with an increase of flow intensity (V/Vc) under different types of steady flow hydrographs. The scour depth decreases with increase of initial bed level (Y=+0.2D*,0D*and -0.2D*) relative under the foundation top elevation of the different type pier. The maximum scour depth occurred in the front of the pier for all conditions. Because of the scouring retardation by the non-uniform plane of foundation, the scour depth is reduced for the un-exposed bridge

  1. Beam envelope profile of non-centrosymmetric polygonal phase space

    International Nuclear Information System (INIS)

    Chen Yinbao; Xie Xi

    1984-01-01

    The general theory of beam envelope profile of non-centrosymmetric polygonal phase space is developed. By means of this theory the beam envelope profile of non-centrosymmetric polygonal phase space can be calculated directly. An example is carried out in detail to show the practical application of the theory

  2. Particle-in-cell simulation of electron trajectories and irradiation uniformity in an annular cathode high current pulsed electron beam source

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Wei; Wang, Langping, E-mail: aplpwang@hit.edu.cn; Zhou, Guangxue; Wang, Xiaofeng

    2017-02-01

    Highlights: • The transmission process of electrons and irradiation uniformity was simulated. • Influence of the irradiation parameters on irradiation uniformity are discussed. • High irradiation uniformity can be obtained in a wide processing window. - Abstract: In order to study electron trajectories in an annular cathode high current pulsed electron beam (HCPEB) source based on carbon fiber bunches, the transmission process of electrons emitted from the annular cathode was simulated using a particle-in-cell model with Monte Carlo collisions (PIC-MCC). The simulation results show that the intense flow of the electrons emitted from the annular cathode are expanded during the transmission process, and the uniformity of the electron distribution is improved in the transportation process. The irradiation current decreases with the irradiation distance and the pressure, and increases with the negative voltage. In addition, when the irradiation distance and the cathode voltage are larger than 40 mm and −15 kV, respectively, a uniform irradiation current distribution along the circumference of the anode can be obtained. The simulation results show that good irradiation uniformity of circular components can be achieved by this annular cathode HCPEB source.

  3. Analysis of single blow effectiveness in non-uniform parallel plate regenerators

    DEFF Research Database (Denmark)

    Jensen, Jesper Buch; Bahl, Christian Robert Haffenden; Engelbrecht, Kurt

    2011-01-01

    Non-uniform distributions of plate spacings in parallel plate regenerators have been found to induce loss of performance. In this paper, it has been investigated how variations of three geometric parameters (the aspect ratio, the porosity, and the standard deviation of the plate spacing) affects...

  4. Efficient SPECT scatter calculation in non-uniform media using correlated Monte Carlo simulation

    International Nuclear Information System (INIS)

    Beekman, F.J.

    1999-01-01

    Accurate simulation of scatter in projection data of single photon emission computed tomography (SPECT) is computationally extremely demanding for activity distribution in non-uniform dense media. This paper suggests how the computation time and memory requirements can be significantly reduced. First the scatter projection of a uniform dense object (P SDSE ) is calculated using a previously developed accurate and fast method which includes all orders of scatter (slab-derived scatter estimation), and then P SDSE is transformed towards the desired projection P which is based on the non-uniform object. The transform of P SDSE is based on two first-order Compton scatter Monte Carlo (MC) simulated projections. One is based on the uniform object (P u ) and the other on the object with non-uniformities (P ν ). P is estimated by P-tilde=P SDSE P ν /P u . A tremendous decrease in noise in P-tilde is achieved by tracking photon paths for P ν identical to those which were tracked for the calculation of P u and by using analytical rather than stochastic modelling of the collimator. The method was validated by comparing the results with standard MC-simulated scatter projections (P) of 99m Tc and 201 Tl point sources in a digital thorax phantom. After correction, excellent agreement was obtained between P-tilde and P. The total computation time required to calculate an accurate scatter projection of an extended distribution in a thorax phantom on a PC is a only few tens of seconds per projection, which makes the method attractive for application in accurate scatter correction in clinical SPECT. Furthermore, the method removes the need of excessive computer memory involved with previously proposed 3D model-based scatter correction methods. (author)

  5. Measuring the ROI on Knowledge Management Systems.

    Science.gov (United States)

    Wickhorst, Vickie

    2002-01-01

    Defines knowledge management and corporate portals and provides a model that can be applied to assessing return on investment (ROI) for a knowledge management solution. Highlights include leveraging knowledge in an organization; assessing the value of human capital; and the Intellectual Capital Performance Measurement Model. (LRW)

  6. The non-uniformity correction factor for the cylindrical ionization chambers in dosimetry of an HDR 192Ir brachytherapy source

    International Nuclear Information System (INIS)

    Majumdar, Bishnu; Patel, Narayan Prasad; Vijayan, V.

    2006-01-01

    The aim of this study is to derive the non-uniformity correction factor for the two therapy ionization chambers for the dose measurement near the brachytherapy source. The two ionization chambers of 0.6 cc and 0.1 cc volume were used. The measurement in air was performed for distances between 0.8 cm and 20 cm from the source in specially designed measurement jig. The non-uniformity correction factors were derived from the measured values. The experimentally derived factors were compared with the theoretically calculated non-uniformity correction factors and a close agreement was found between these two studies. The experimentally derived non-uniformity correction factor supports the anisotropic theory. (author)

  7. ROI en medios sociales: campañas de marketing en bibliotecas

    OpenAIRE

    González-Fernández-Villavicencio, Nieves

    2015-01-01

    Social media marketing must be a part of a digital marketing plan. Although marketing traditionally has been associated with obtaining an economic ROI (return on investment), it also can be measured in terms of social ROI (return on influence, return on relationships, reputation, branding, etc.). This study addresses the use of digital marketing campaigns by libraries for social profitability. Concepts related to digital marketing and social media marketing, and the way different types of org...

  8. Generating and measuring non-diffracting vector Bessel beams

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2014-03-01

    Full Text Available We demonstrate how to create non-diffracting vector Bessel beams by implementing a spatial light modulator (SLM) to generate scalar Bessel beams which are then converted into vector fields by the use of an azimuthally-varying birefringent plate...

  9. On the burnout in annular channels at non-uniform heat release distribution in length

    International Nuclear Information System (INIS)

    Ornatskij, A.P.; Chernobaj, V.A.; Vasil'ev, A.F.; Struts, G.V.

    1982-01-01

    The effect of axial heat release non-uniformity on the conditions of the burnout in annular channels is investigated. The investigation is carried out in annular channels with different laws of heat flux density distribution by channel length. The heat release non-uniformity coefficient was varied from 4.4 to 10, the pressure from 9.8 to 17.6 MPa, mass rate from 500 to 1700 kg (m 2 xS), liquid temperature (chemically desalted water) at the channel inlet constituted 30-300 deg C. The experiments have been performed at the test bench with a closed circulation circuit. The data obtained testify to the fact that under non-uniform heat release the influence of main operating parameters on the value of critical power is of the same character as under uniform heat release. The character of wall temperature variation by channel length before the burnout is determined by the form of heat supply temperature profile. The temperature maximum is observed in the region lying behind the cross section with maximum heat flux. The conclusion is drawn that the dominant influence on the position of the cross section in which the burnout arises is exerted by the form of heat flux density distribution by length. Independently of this distribution form the burnout developes when the vapour content near the wall reaches a limiting value

  10. Energy-Efficient Algorithm for Sensor Networks with Non-Uniform Maximum Transmission Range

    Directory of Open Access Journals (Sweden)

    Yimin Yu

    2011-06-01

    Full Text Available In wireless sensor networks (WSNs, the energy hole problem is a key factor affecting the network lifetime. In a circular multi-hop sensor network (modeled as concentric coronas, the optimal transmission ranges of all coronas can effectively improve network lifetime. In this paper, we investigate WSNs with non-uniform maximum transmission ranges, where sensor nodes deployed in different regions may differ in their maximum transmission range. Then, we propose an Energy-efficient algorithm for Non-uniform Maximum Transmission range (ENMT, which can search approximate optimal transmission ranges of all coronas in order to prolong network lifetime. Furthermore, the simulation results indicate that ENMT performs better than other algorithms.

  11. Acoustic holography for piston sound radiation with non-uniform velocity profiles

    NARCIS (Netherlands)

    Aarts, R.M.; Janssen, A.J.E.M.

    2010-01-01

    The theory of orthogonal (Zernike) expansions of functions on a disk, as used in the diffraction theory of optical aberrations, is applied to obtain (semi-) analytical results for the radiation of sound due to a non-uniformly moving, baffled, circular piston. For this particular case, a scheme for

  12. Dilute: A code for studying beam evolution under rf noise

    International Nuclear Information System (INIS)

    Shih, H.; Ellison, J.A.; Schiesser, W.E.

    1993-01-01

    Longitudinal beam dynamics under rf noise has been modeled by Dome, Krinsky, and Wang using a diffusion-in-action PDE. If the primary interest is the evolution of the beam in action, it is much simpler to integrate the model PDE than to undertake tracking simulations. Here we describe the code that we developed to solve the model PDE using the numerical Method of Lines. Features of the code include (1) computation of the distribution in action for the initial beam from a Gaussian or user-supplied distribution in longitudinal phase space, (2) computation of the diffusion coefficient for white noise or from a user-supplied spectral density for non-white noise, (3) discretization of the model PDE using finite-difference or Galerkin finite-element approximations with a uniform or non-uniform grid, and (4) integration of the system of ODEs in time by the solver RKF45 or a user-supplied ODE solver

  13. In situ study of the impact of inter- and intra-reader variability on region of interest (ROI) analysis in preclinical molecular imaging.

    Science.gov (United States)

    Habte, Frezghi; Budhiraja, Shradha; Keren, Shay; Doyle, Timothy C; Levin, Craig S; Paik, David S

    2013-01-01

    We estimated reader-dependent variability of region of interest (ROI) analysis and evaluated its impact on preclinical quantitative molecular imaging. To estimate reader variability, we used five independent image datasets acquired each using microPET and multispectral fluorescence imaging (MSFI). We also selected ten experienced researchers who utilize molecular imaging in the same environment that they typically perform their own studies. Nine investigators blinded to the data type completed the ROI analysis by drawing ROIs manually that delineate the tumor regions to the best of their knowledge and repeated the measurements three times, non-consecutively. Extracted mean intensities of voxels within each ROI are used to compute the coefficient of variation (CV) and characterize the inter- and intra-reader variability. The impact of variability was assessed through random samples iterated from normal distributions for control and experimental groups on hypothesis testing and computing statistical power by varying subject size, measured difference between groups and CV. The results indicate that inter-reader variability was 22.5% for microPET and 72.2% for MSFI. Additionally, mean intra-reader variability was 10.1% for microPET and 26.4% for MSFI. Repeated statistical testing showed that a total variability of CV variability has been observed mainly due to differences in the ROI placement and geometry drawn between readers, which may adversely affect statistical power and erroneously lead to negative study outcomes.

  14. The Superconvergence Phenomenon and Proof of the MAC Scheme for the Stokes Equations on Non-uniform Rectangular Meshes

    KAUST Repository

    Li, Jichun

    2014-12-02

    For decades, the widely used finite difference method on staggered grids, also known as the marker and cell (MAC) method, has been one of the simplest and most effective numerical schemes for solving the Stokes equations and Navier–Stokes equations. Its superconvergence on uniform meshes has been observed by Nicolaides (SIAM J Numer Anal 29(6):1579–1591, 1992), but the rigorous proof is never given. Its behavior on non-uniform grids is not well studied, since most publications only consider uniform grids. In this work, we develop the MAC scheme on non-uniform rectangular meshes, and for the first time we theoretically prove that the superconvergence phenomenon (i.e., second order convergence in the (Formula presented.) norm for both velocity and pressure) holds true for the MAC method on non-uniform rectangular meshes. With a careful and accurate analysis of various sources of errors, we observe that even though the local truncation errors are only first order in terms of mesh size, the global errors after summation are second order due to the amazing cancellation of local errors. This observation leads to the elegant superconvergence analysis even with non-uniform meshes. Numerical results are given to verify our theoretical analysis.

  15. A METHOD FOR EVALUATION OF NON-UNIFORM RADIANT-CONVECTIVE LOAD ON HUMAN BODY DURING MENTAL WORK

    Directory of Open Access Journals (Sweden)

    Lenka Prokšová Zuská

    2017-10-01

    Full Text Available The objective of this study was to develop a documentation for the amendment of the microclimatic part of the Czech Government Regulation, particularly in a non-uniform radiant-convective load evaluation. Changes in regulation were made based on experimental data obtained on a group of experimental individuals in a climatic chamber. One of the objectives of the climatic chamber experiments was to evaluate whether there was a possibility to use an alternative method, which utilizes a new value – stereotemperature, for the assessment. A group of 24 women was exposed to a non-uniform radiant-convective load in a climatic chamber for 1 hour during their computer work. Measurements were divided according to the globe temperature into 3 stages. The physical parameters of air were continuously measured: the air temperature, globe temperature, air velocity, radiant temperature, relative humidity, stereotemperature and physiological parameters. Thermal sensations of experimental subjects were expressed in the seven-point scale according to EN ISO 7730. The thermal sensation correlated very well with the difference of stereotemperature and the globe temperature. The stereotemperature correlated very well with the radiant temperature. In this work, the composed equations were used to develop the limit values for the thermal stress evaluation in the uniform and non-uniform thermal environment at workplaces. It is possible to determine how the body of an exposed person perceives the non-uniform climatic conditions in the indoor environment, by adding the stereotemperature to government regulations.

  16. Numerical analysis of blood flow in realistic arteries subjected to strong non-uniform magnetic fields

    International Nuclear Information System (INIS)

    Kenjeres, Sasa

    2008-01-01

    The paper reports on a comprehensive mathematical model for simulations of blood flow under the presence of strong non-uniform magnetic fields. The model consists of a set of Navier-Stokes equations accounting for the Lorentz and magnetisation forces, and a simplified set of Maxwell's equations (Biot-Savart/Ampere's law) for treating the imposed magnetic fields. The relevant hydrodynamic and electromagnetic properties of human blood were taken from the literature. The model is then validated for different test cases ranging from a simple cylindrical geometry to real-life right-coronary arteries in humans. The time-dependency of the wall-shear-stress for different stenosis growth rates and the effects of the imposed strong non-uniform magnetic fields on the blood flow pattern are presented and analysed. It is concluded that an imposed non-uniform magnetic field can create significant changes in the secondary flow patterns, thus making it possible to use this technique for optimisations of targeted drug delivery

  17. Numerical research on natural convection in molten salt reactor with non-uniformly distributed volumetric heat generation

    International Nuclear Information System (INIS)

    Qian Libo; Qiu Suizheng; Zhang Dalin; Su Guanghui; Tian Wenxi

    2010-01-01

    Molten salt reactor is one of the six Generation IV systems capable of breeding and transmutation of actinides and long-lived fission products, which uses the liquid molten salt as the fuel solvent, coolant and heat generation simultaneously. The present work presents a numerical investigation on natural convection with non-uniform heat generation through which the heat generated by the fluid fuel is removed out of the core region when the reactor is under post-accident condition or zero-power condition. The two-group neutron diffusion equation is applied to calculated neutron flux distribution, which leads to non-uniform heat generation. The SIMPLER algorithm is used to calculate natural convective heat transfer rate with isothermal or adiabatic rigid walls. These two models are coupled through the temperature field and heat sources. The peculiarities of natural convection with non-uniform heat generation are investigated in a range of Ra numbers (10 3 ∼ 10 7 ) for the laminar regime of fluid motion. In addition, the numerical results are also compared with those containing uniform heat generation.

  18. Achieving uniform dose with the use of a custom tissue compensator and a leveled beam for tangential breast fields

    International Nuclear Information System (INIS)

    Asbury, L.; Luttrell, L.; Lake, D.

    1989-01-01

    In order to achieve uniform dose distribution in intact breast treatments, wedges can be employed. This paper will describe a custom compensator made from brass chips used in conjunction with a leveled beam and a custom cast to treat breast shapes that are less suited to a standard wedge set up. Materials and design, dosimetry, criteria, efficacy and results will be described

  19. Simple model of electron beam initiated dielectric breakdown

    International Nuclear Information System (INIS)

    Beers, B.L.; Daniell, R.E.; Delmer, T.N.

    1985-01-01

    A steady state model that describes the internal charge distribution of a planar dielectric sample exposed to a uniform electron beam was developed. The model includes the effects of charge deposition and ionization of the beam, separate trap-modulated mobilities for electrons and holes, electron-hole recombination, and pair production by drifting thermal electrons. If the incident beam current is greater than a certain critical value (which depends on sample thickness as well as other sample properties), the steady state solution is non-physical

  20. Uniformity calibration for ICT image

    International Nuclear Information System (INIS)

    Zeng Gang; Liu Li; Que Jiemin; Zhang Yingping; Yin Yin; Wang Yanfang; Yu Zhongqiang; Yan Yonglian

    2004-01-01

    The uniformity of ICT image is impaired by beam hardening and the inconsistency of detector units responses. The beam hardening and the nonlinearity of the detector's output have been analyzed. The correction factors are determined experimentally by the detector's responses with different absorption length. The artifacts in the CT image of a symmetrical aluminium cylinder have been eliminated after calibration. (author)

  1. Determination of the meniscus shape of a negative ion beam from an experimentally obtained beam profile

    Science.gov (United States)

    Ichikawa, M.; Kojima, A.; Chitarin, G.; Agostinetti, P.; Aprile, D.; Baltador, C.; Barbisan, M.; Delogu, R.; Hiratsuka, J.; Marconato, N.; Nishikiori, R.; Pimazzoni, A.; Sartori, E.; Serianni, G.; Tobari, H.; Umeda, N.; Veltri, P.; Watanabe, K.; Yoshida, M.; Antoni, V.; Kashiwagi, M.

    2017-08-01

    In order to understand the physics mechanism of a negative ion extraction in negative ion sources, an emission surface of the negative ions around an aperture at a plasma grid, so-called a meniscus, has been analyzed by an inverse calculation of the negative ion trajectory in a two dimensional beam analysis code. In this method, the meniscus is defined as the final position of the negative ion trajectories which are inversely calculated from the measured beam profile to the plasma grid. In a case of the volume-produced negative ions, the calculated meniscus by the inverse calculation was similar to that obtained in conventional beam simulation codes for positive ion extractions such as BEAMORBT and SLACCAD. The negative ion current density was uniform along the meniscus. This indicates that the negative ions produced in the plasma are transported to the plasma grid uniformly as considered in the transportation of the positive ions. However, in a surface production case of negative ions, where the negative ions are generated near the plasma grid with lower work function by seeding cesium, the current density in the peripheral region of the meniscus close to the plasma grid surface was estimated to be 2 times larger than the center region, which suggested that the extraction process of the surface-produced negative ions was much different with that for the positive ions. Because this non-uniform profile of the current density made the meniscus shape strongly concave, the beam extracted from the peripheral region could have a large divergence angle, which might be one of origins of so-called beam halo. This is the first results of the determination of the meniscus based on the experiment, which is useful to improve the prediction of the meniscus shape and heat loads based on the beam trajectories including beam halo.

  2. SU-F-J-29: Dosimetric Effect of Image Registration ROI Size and Focus in Automated CBCT Registration for Spine SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Magnelli, A; Smith, A; Chao, S; Suh, J; Xia, P [The Cleveland Clinic Foundation, Cleveland, OH (United States)

    2016-06-15

    Purpose: Spinal stereotactic body radiotherapy (SBRT) involves highly conformal dose distributions and steep dose gradients due to the proximity of the spinal cord to the treatment volume. To achieve the planning goals while limiting the spinal cord dose, patients are setup using kV cone-beam CT (kV-CBCT) with 6 degree corrections. The kV-CBCT registration with the reference CT is dependent on a user selected region of interest (ROI). The objective of this work is to determine the dosimetric impact of ROI selection. Methods: Twenty patients were selected for this study. For each patient, the kV-CBCT was registered to the reference CT using three ROIs including: 1) the external body, 2) a large anatomic region, and 3) a small region focused in the target volume. Following each registration, the aligned CBCTs and contours were input to the treatment planning system for dose evaluation. The minimum dose, dose to 99% and 90% of the tumor volume (D99%, D90%), dose to 0.03cc and the dose to 10% of the spinal cord subvolume (V10Gy) were compared to the planned values. Results: The average deviations in the tumor minimum dose were 2.68%±1.7%, 4.6%±4.0%, 14.82%±9.9% for small, large and the external ROIs, respectively. The average deviations in tumor D99% were 1.15%±0.7%, 3.18%±1.7%, 10.0%±6.6%, respectively. The average deviations in tumor D90% were 1.00%±0.96%, 1.14%±1.05%, 3.19%±4.77% respectively. The average deviations in the maximum dose to the spinal cord were 2.80%±2.56%, 7.58%±8.28%, 13.35%±13.14%, respectively. The average deviation in V10Gy to the spinal cord were 1.69%±0.88%, 1.98%±2.79%, 2.71%±5.63%. Conclusion: When using automated registration algorithms for CBCT-Reference alignment, a small target-focused ROI results in the least dosimetric deviation from the plan. It is recommended to focus narrowly on the target volume to keep the spinal cord dose below tolerance.

  3. Impact of roof height non-uniformity on pollutant transport between a street canyon and intersections

    International Nuclear Information System (INIS)

    Nosek, Štěpán; Kukačka, Libor; Jurčáková, Klára; Kellnerová, Radka; Jaňour, Zbyněk

    2017-01-01

    This paper presents an extension of our previous wind-tunnel study (Nosek et al., 2016) in which we highlighted the need for investigation of the removal mechanisms of traffic pollution from all openings of a 3D street canyon. The extension represents the pollution flux (turbulent and advective) measurements at the lateral openings of three different 3D street canyons for the winds perpendicular and oblique to the along-canyon axis. The pollution was simulated by emitting a passive gas (ethane) from a homogeneous ground-level line source positioned along the centreline of the investigated street canyons. The street canyons were formed by courtyard-type buildings of two different regular urban-array models. The first model has a uniform building roof height, while the second model has a non-uniform roof height along each building's wall. The mean flow and concentration fields at the canyons' lateral openings confirm the findings of other studies that the buildings' roof-height variability at the intersections plays an important role in the dispersion of the traffic pollutants within the canyons. For the perpendicular wind, the non-uniform roof-height canyon appreciably removes or entrains the pollutant through its lateral openings, contrary to the uniform canyon, where the pollutant was removed primarily through the top. The analysis of the turbulent mass transport revealed that the coherent flow structures of the lateral momentum transport correlate with the ventilation processes at the lateral openings of all studied canyons. These flow structures coincide at the same areas and hence simultaneously transport the pollutant in opposite directions. - Highlights: • The pollutant transport strongly depends on the roof-height arrangement. • The non-uniform canyons also remove the pollutants through their lateral openings. • The higher the upstream wall, the more pollutant is removed through the top. • The lateral coherent structures correlate

  4. An example of enhancement of a non-classical feature of a light beam by mixing with another classical light beam using a beam splitter

    International Nuclear Information System (INIS)

    Prakash, Hari; Mishra, Devendra Kumar

    2005-01-01

    We present here an example where a non-classical feature of a light beam is enhanced simply by mixing with another classical coherent light beam using a beam splitter. This non-classical feature is amplitude-squared squeezing of a Gaussian light beam expressed by a negative value of Y e or a negative value of the normalized quantity W e which can become more negative on enhancement. Here, these values comprise the density, annihilation and creation operators, respectively

  5. Effect of non-uniform surface resistance on the quality factor of superconducting niobium cavity

    Science.gov (United States)

    Tan, Weiwei; Lu, Xiangyang; Yang, Ziqin; Zhao, Jifei; Yang, Deyu; Yang, Yujia

    2016-08-01

    The formula Rs = G /Q0 is commonly used in the calculation of the surface resistance of radio frequency niobium superconducting cavities. The applying of such equation is under the assumption that surface resistance is consistent over the cavity. However, the distribution of the magnetic field varies over the cavity. The magnetic field in the equator is much higher than that in the iris. According to Thermal Feedback Theory, it leads non-uniform distribution of the density of heat flux, which results in a different temperature distribution along the cavity inter surface. The BCS surface resistance, which depends largely on the temperature, is different in each local inner surface. In this paper, the effect of surface non-uniform resistance on the quality factor has been studied, through the calculation of Q0 in the original definition of it. The results show that it is necessary to consider the non-uniform distribution of magnetic field when the accelerating field is above 20 MV/m for TESLA cavities. Also, the effect of inhomogeneity of residual resistance on the quality factor is discussed. Its distribution barely affects the quality factor.

  6. Design of multiplier-less sharp non-uniform cosine modulated filter banks for efficient channelizers in software defined radio

    Directory of Open Access Journals (Sweden)

    Shaeen Kalathil

    2016-03-01

    Full Text Available Forthcoming software defined radios require filter banks which satisfy stringent specifications efficiently with low implementation complexity. Cosine modulated filter banks (CMFB have simple and efficient design procedure. The different wireless standards have different channel spacing or bandwidths and hence demand non-uniform decomposition of subbands. The non-uniform CMFB can be obtained from a uniform CMFB in a simple and efficient approach by merging the adjacent channels of the uniform CMFB. Very narrow transition width filters with low complexity can be achieved using frequency response masking (FRM filter as prototype filter. The complexity is further reduced by the multiplier-less realization of filter banks in which the least number of signed power of two (SPT terms is achieved by representing the filter coefficients using canonic signed digit (CSD representation and then optimizing using suitable modified meta-heuristic algorithms. Hybrid meta-heuristic algorithms are used in this paper. A hybrid algorithm combines the qualities of two meta-heuristic algorithms and results in improved performances with low implementation complexity. Highly frequency selective filter banks characterized by small passband ripple, narrow transition width and high stopband attenuation with non-uniform decomposition of subbands can be designed with least the implementation complexity, using this approach. A digital channelizer can be designed for SDR implementations, using the proposed approach. In this paper, the non-uniform CMFB is designed for various existing wireless standards.

  7. Theoretical investigations on two-phase flow instability in parallel channels under axial non-uniform heating

    International Nuclear Information System (INIS)

    Lu, Xiaodong; Wu, Yingwei; Zhou, Linglan; Tian, Wenxi; Su, Guanghui; Qiu, Suizheng; Zhang, Hong

    2014-01-01

    Highlights: • We developed a model based on homogeneous flow model to analyze two-phase flow instability in parallel channels. • The influence of axial non-uniform heating on the system stability has been investigated. • Influences of various factors on system instability under cosine heat flux have been studied. • The system under top-peaked heat flux is the most stable system. - Abstract: Two-phase flow instability in parallel channels heated by axial non-uniform heat flux has been theoretically studied in this paper. The system control equations of parallel channels were established based on the homogeneous flow model in two-phase region. Semi-implicit finite-difference scheme and staggered mesh method were used to discretize the equations, and the difference equations were solved by chasing method. Cosine, bottom-peaked and top-peaked heat fluxes were used to study the influence of non-uniform heating on two-phase flow instability of the parallel channels system. The marginal stability boundaries (MSB) of parallel channels and three-dimensional instability spaces (or instability reefs) under different heat flux conditions have been obtained. Compared with axial uniform heating, axial non-uniform heating will affect the system stability. Cosine and bottom-peaked heat fluxes can destabilize the system stability in high inlet subcooling region, while the opposite effect can be found in low inlet subcooling region. However, top-peaked heat flux can enhance the system stability in the whole region. In addition, for cosine heat flux, increasing the system pressure or inlet resistance coefficient can strengthen the system stability, and increasing the heating power will destabilize the system stability. The influence of inlet subcooling number on the system stability is multi-valued under cosine heat flux

  8. Improving emission uniformity and linearizing band dispersion in nanowire arrays using quasi-aperiodicity

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, P. Duke [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Univ. of Southern California, Los Angeles, CA (United States). Ming Hsieh Dept. of Electrical Engineering; Koleske, Daniel D. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Povinelli, Michelle L. [Univ. of Southern California, Los Angeles, CA (United States). Ming Hsieh Dept. of Electrical Engineering; Subramania, Ganapathi [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2017-10-01

    For this study, we experimentally investigate a new class of quasi-aperiodic structures for improving the emission pattern in nanowire arrays. Efficient normal emission, as well as lasing, can be obtained from III-nitride photonic crystal (PhC) nanowire arrays that utilize slow group velocity modes near the Γ-point in reciprocal space. However, due to symmetry considerations, the emitted far-field pattern of such modes are often ‘donut’-like. Many applications, including lighting for displays or lasers, require a more uniform beam profile in the far-field. Previous work has improved far-field beam uniformity of uncoupled modes by changing the shape of the emitting structure. However, in nanowire systems, the shape of nanowires cannot always be arbitrarily changed due to growth or etch considerations. Here, we investigate breaking symmetry by instead changing the position of emitters. Using a quasi-aperiodic geometry, which changes the emitter position within a photonic crystal supercell (2x2), we are able to linearize the photonic bandstructure near the Γ-point and greatly improve emitted far-field uniformity. We realize the III-nitride nanowires structures using a top-down fabrication procedure that produces nanowires with smooth, vertical sidewalls. Comparison of room-temperature micro-photoluminescence (µ-PL) measurements between periodic and quasi-aperiodic nanowire arrays reveal resonances in each structure, with the simple periodic structure producing a donut beam in the emitted far-field and the quasi-aperiodic structure producing a uniform Gaussian-like beam. We investigate the input pump power vs. output intensity in both systems and observe the simple periodic array exhibiting a non-linear relationship, indicative of lasing. We believe that the quasi-aperiodic approach studied here provides an alternate and promising strategy for shaping the emission pattern of nanoemitter systems.

  9. Characterization and Beam Tests Results of Non-Uniformly Irradiated 3D Pixel Sensors for HEP Experiments

    International Nuclear Information System (INIS)

    Lopez, I.; Grinstein, S.; Micelli, A.; Tsiskaridze, S.

    2013-06-01

    3D Pixel detectors, with cylindrical electrodes that penetrate the silicon substrate, offer advantages over standard planar sensors in terms of radiation hardness, since the charge collection distance can be reduced independently of the bulk thickness. In the framework of the ATLAS Forward Physics (AFP) program, work has been carried out to study the suitability of 3D pixel devices for forward proton tracking. The AFP tracker unit will consist of an array of five pixel sensors placed at 2-3 mm from the Large Hadron Collider (LHC) proton beam. The proximity to the beam is essential for the AFP physics program as it directly increases the sensitivity of the experiment. Thus, there are two critical requirements for the AFP pixel detector. First, the dead region of the sensor has to be minimized. Second, the device has to be able to cope with a very inhomogeneous radiation distribution. Recent results of the characterization and beam test studies of in-homogeneously irradiated 3D pixel sensors produced at CNM-Barcelona will be presented. (authors)

  10. Concave pulse shaping of a circularly polarized laser pulse from non-uniform overdense plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Hur, Min Sup [School of Natural Science, UNIST, BanYeon-Ri 100, Ulju-gun, Ulsan, 689-798 (Korea, Republic of); Kulagin, Victor V. [Sternberg Astronomical Institute, Moscow State University, Universitetsky prosp. 13, Moscow, 119992 (Russian Federation); Suk, Hyyong, E-mail: hysuk@gist.ac.kr [Department of Physics and Photon Science, GIST, 123 Cheomdan-gwangiro, Buk-gu, Gwangju, 500-712 (Korea, Republic of)

    2015-03-20

    Pulse shaping of circularly polarized laser pulses in nonuniform overdense plasmas are investigated numerically. Specifically we show by two-dimensional particle-in-cell simulations the generation of a concave pulse front of a circularly polarized, a few tens of petawatt laser pulse from a density-tapered, overdense plasma slab. The concept used for the transverse-directional shaping is the differential transmittance depending on the plasma density, and the laser intensity. For suitable selection of the slab parameters for the concave pulse shaping, we studied numerically the pulse transmittance, which can be used for further parameter design of the pulse shaping. The concavely shaped circularly polarized pulse is expected to add more freedom in controlling the ion-beam characteristics in the RPDA regime. - Highlights: • Laser pulse shaping for a concave front by non-uniform overdense plasma was studied. • Particle-in-cell (PIC) simulations were used for the investigation. • A laser pulse can be shaped by a density-tapered overdense plasma. • The concave and sharp pulse front are useful in many laser–plasma applications. • They are important for ion acceleration, especially in the radiation pressure dominant regime.

  11. Return on investment. What is ROI and how to use it.

    Science.gov (United States)

    Cotter, Steve

    2014-08-01

    Formulated and interpreted correctly, ROI tools and techniques can be very useful for EMS managers when evaluating various competing projects and initiatives within the organization. More so, decision makers and elected bodies responsible for approving the financial support of these initiatives are demanding that they be presented with a more complete picture of the return for any dollars allocated under ever-tightening financial considerations that all organizations face today. ROI can be a powerful tool in supporting your organization when competing for limited dollars.

  12. The hands-on project office guaranteeing ROI and on-time delivery

    CERN Document Server

    Kesner, Richard M

    2003-01-01

    THE THREE PILLARS OF IT DELIVERY - PROBLEM RESOLUTION, SERVICE REQUESTS, AND PROJECTSIntroduction The Business Context The Internal Economy for Investing in IT Services and ProjectsThe Three Pillars of IT Delivery Managing Service DeliveryManaging Project Commitments IT Metrics and Reporting Tools THE PROJECT MANAGEMENT OFFICE BUSINESS MODELIntroduction: Revisiting the IT Organization IT Service and Project Delivery RolesThe Role of the Project Management Office: Measuring its ROI The PMO Value Proposition: An Initial ROI Estimate ALIGNMENT AND PLANNING - DOING THE RIGHT THINGS Introduction Ge

  13. Propagation of Gaussian Beams through Active GRIN Materials

    International Nuclear Information System (INIS)

    Gomez-Varela, A I; Flores-Arias, M T; Bao-Varela, C; Gomez-Reino, C; De la Fuente, X

    2011-01-01

    We discussed light propagation through an active GRIN material that exhibits loss or gain. Effects of gain or loss in GRIN materials can be phenomenologically taken into account by using a complex refractive index in the wave equation. This work examines the implication of using a complex refractive index on light propagation in an active GRIN material illuminated by a non-uniform monochromatic wave described by a Gaussian beam. We analyze how a Gaussian beam is propagated through the active material in order to characterize it by the beam parameters and the transverse irradiance distribution.

  14. Atomic layer deposition of HfO2 on graphene through controlled ion beam treatment

    International Nuclear Information System (INIS)

    Kim, Ki Seok; Oh, Il-Kwon; Jung, Hanearl; Kim, Hyungjun; Yeom, Geun Young; Kim, Kyong Nam

    2016-01-01

    The polymer residue generated during the graphene transfer process to the substrate tends to cause problems (e.g., a decrease in electron mobility, unwanted doping, and non-uniform deposition of the dielectric material). In this study, by using a controllable low-energy Ar + ion beam, we cleaned the polymer residue without damaging the graphene network. HfO 2 grown by atomic layer deposition on graphene cleaned using an Ar + ion beam showed a dense uniform structure, whereas that grown on the transferred graphene (before Ar + ion cleaning) showed a non-uniform structure. A graphene–HfO 2 –metal capacitor fabricated by growing 20-nm thick HfO 2 on graphene exhibited a very low leakage current (<10 −11 A/cm 2 ) for Ar + ion-cleaned graphene, whereas a similar capacitor grown using the transferred graphene showed high leakage current.

  15. Non-uniform approximations for sums of discrete m-dependent random variables

    OpenAIRE

    Vellaisamy, P.; Cekanavicius, V.

    2013-01-01

    Non-uniform estimates are obtained for Poisson, compound Poisson, translated Poisson, negative binomial and binomial approximations to sums of of m-dependent integer-valued random variables. Estimates for Wasserstein metric also follow easily from our results. The results are then exemplified by the approximation of Poisson binomial distribution, 2-runs and $m$-dependent $(k_1,k_2)$-events.

  16. Modelling non-uniform strain distributions in aerospace composites using fibre Bragg gratings

    NARCIS (Netherlands)

    Rajabzadehdizaji, Aydin; Groves, R.M.; Hendriks, R.C.; Heusdens, R.; Chung, Y.; Jin, W.; Lee, B.; Canning, J.; Nakamura, K.; Yuan, L.

    2017-01-01

    In this paper the behaviour of fibre Bragg grating (FBG) sensors under non-uniform strain distributions was analysed. Using the fundamental matrix approach, the length of the FBG sensor was discretised, with each segment undergoing different strain values. FBG sensors that are embedded inside

  17. System for monitoring the position, intensity, uniformity, and directivity of a beam of ionizing radiation

    International Nuclear Information System (INIS)

    Boux, R.

    1976-01-01

    A monitoring device transparent to ionizing radiation, designed to measure the orientation, intensity and uniformity of an incident beam, comprises a cylindrical housing forming at least one ionization chamber with one or more ion-collecting electrodes transverse to the housing axis, each electrode being subdivided into a plurality of mutually insulated conductive elements connected to respective amplifiers. The elements of at least one electrode include one or more outer elements surrounding or bracketing one or more inner elements to measure the radiation in a central zone and a peripheral zone. The outputs of the respective amplifiers are additively and subtractively combined in an evaluation circuit

  18. SYSTEMATIC ERROR REDUCTION: NON-TILTED REFERENCE BEAM METHOD FOR LONG TRACE PROFILER

    International Nuclear Information System (INIS)

    QIAN, S.; QIAN, K.; HONG, Y.; SENG, L.; HO, T.; TAKACS, P.

    2007-01-01

    Systematic error in the Long Trace Profiler (LTP) has become the major error source as measurement accuracy enters the nanoradian and nanometer regime. Great efforts have been made to reduce the systematic error at a number of synchrotron radiation laboratories around the world. Generally, the LTP reference beam has to be tilted away from the optical axis in order to avoid fringe overlap between the sample and reference beams. However, a tilted reference beam will result in considerable systematic error due to optical system imperfections, which is difficult to correct. Six methods of implementing a non-tilted reference beam in the LTP are introduced: (1) application of an external precision angle device to measure and remove slide pitch error without a reference beam, (2) independent slide pitch test by use of not tilted reference beam, (3) non-tilted reference test combined with tilted sample, (4) penta-prism scanning mode without a reference beam correction, (5) non-tilted reference using a second optical head, and (6) alternate switching of data acquisition between the sample and reference beams. With a non-tilted reference method, the measurement accuracy can be improved significantly. Some measurement results are presented. Systematic error in the sample beam arm is not addressed in this paper and should be treated separately

  19. Application of a semi-automatic ROI setting system for brain PET images to animal PET studies

    International Nuclear Information System (INIS)

    Kuge, Yuji; Akai, Nobuo; Tamura, Koji

    1998-01-01

    ProASSIST, a semi-automatic ROI (region of interest) setting system for human brain PET images, has been modified for use with the canine brain, and the performance of the obtained system was evaluated by comparing the operational simplicity for ROI setting and the consistency of ROI values obtained with those by a conventional manual procedure. Namely, we created segment maps for the canine brain by making reference to the coronal section atlas of the canine brain by Lim et al., and incorporated them into the ProASSIST system. For the performance test, CBF (cerebral blood flow) and CMRglc (cerebral metabolic rate in glucose) images in dogs with or without focal cerebral ischemia were used. In ProASSIST, brain contours were defined semiautomatically. In the ROI analysis of the test image, manual modification of the contour was necessary in half cases examined (8/16). However, the operation was rather simple so that the operation time per one brain section was significantly shorter than that in the manual operation. The ROI values determined by the system were comparable with those by the manual procedure, confirming the applicability of the system to these animal studies. The use of the system like the present one would also merit the more objective data acquisition for the quantitative ROI analysis, because no manual procedure except for some specifications of the anatomical features is required for ROI setting. (author)

  20. Effects of ROI definition and reconstruction method on quantitative outcome and applicability in a response monitoring trial

    International Nuclear Information System (INIS)

    Krak, Nanda C.; Boellaard, R.; Hoekstra, Otto S.; Hoekstra, Corneline J.; Twisk, Jos W.R.; Lammertsma, Adriaan A.

    2005-01-01

    Quantitative measurement of tracer uptake in a tumour can be influenced by a number of factors, including the method of defining regions of interest (ROIs) and the reconstruction parameters used. The main purpose of this study was to determine the effects of different ROI methods on quantitative outcome, using two reconstruction methods and the standard uptake value (SUV) as a simple quantitative measure of FDG uptake. Four commonly used methods of ROI definition (manual placement, fixed dimensions, threshold based and maximum pixel value) were used to calculate SUV (SUV [MAN] , SUV 15 mm , SUV 50 , SUV 75 and SUV max , respectively) and to generate ''metabolic'' tumour volumes. Test-retest reproducibility of SUVs and of ''metabolic'' tumour volumes and the applicability of ROI methods during chemotherapy were assessed. In addition, SUVs calculated on ordered subsets expectation maximisation (OSEM) and filtered back-projection (FBP) images were compared. ROI definition had a direct effect on quantitative outcome. On average, SUV [MAN] , SUV 15 mm , SUV 50 and SUV 75 , were respectively 48%, 27%, 34% and 15% lower than SUV max when calculated on OSEM images. No statistically significant differences were found between SUVs calculated on OSEM and FBP reconstructed images. Highest reproducibility was found for SUV 15 mm and SUV [MAN] (ICC 0.95 and 0.94, respectively) and for ''metabolic'' volumes measured with the manual and 50% threshold ROIs (ICC 0.99 for both). Manual, 75% threshold and maximum pixel ROIs could be used throughout therapy, regardless of changes in tumour uptake or geometry. SUVs showed the same trend in relative change in FDG uptake after chemotherapy, irrespective of the ROI method used. The method of ROI definition has a direct influence on quantitative outcome. In terms of simplicity, user-independence, reproducibility and general applicability the threshold-based and fixed dimension methods are the best ROI methods. Threshold methods are in

  1. Integral dose investigation of non-coplanar treatment beam geometries in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Dan; Dong, Peng; Ruan, Dan; Low, Daniel A.; Sheng, Ke, E-mail: ksheng@mednet.ucla.edu [Department of Radiation Oncology, University of California, Los Angeles, California 90095 (United States); Long, Troy; Romeijn, Edwin [Department of Industrial and Operations, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2014-01-15

    Purpose: Automated planning and delivery of non-coplanar plans such as 4π radiotherapy involving a large number of fields have been developed to take advantage of the newly available automated couch and gantry on C-arm gantry linacs. However, there is an increasing concern regarding the potential changes in the integral dose that needs to be investigated. Methods: A digital torso phantom and 22 lung and liver stereotactic body radiation therapy (SBRT) patients were included in the study. The digital phantom was constructed as a water equivalent elliptical cylinder with a major axis length of 35.4 cm and minor axis of 23.6 cm. A 4.5 cm diameter target was positioned at varying depths along the major axis. Integral doses from intensity modulated, non-coplanar beams forming a conical pattern were compared against the equally spaced coplanar beam plans. Integral dose dependence on the phantom geometry and the beam number was also quantified. For the patient plans, the non-coplanar and coplanar beams and fluences were optimized using a column generation and pricing approach and compared against clinical VMAT plans using two full (lung) or partial coplanar arcs (liver) entering at the side proximal to the tumor. Both the average dose to the normal tissue volume and the total volumes receiving greater than 2 Gy (V2) and 5 Gy (V5) were evaluated and compared. Results: The ratio of integral dose from the non-coplanar and coplanar plans depended on the tumor depth for the phantom; for tumors shallower than 10 cm, the non-coplanar integral doses were lower than coplanar integral doses for non-coplanar angles less than 60°. Similar patterns were observed in the patient plans. The smallest non-coplanar integral doses were observed for tumor 6–8 cm deep. For the phantom, the integral dose was independent of the number of beams, consistent with the liver SBRT patients but the lung SBRT patients showed slight increase in the integral dose when more beams were used. Larger

  2. What's the ROI for resolving the nursing faculty shortage?

    Science.gov (United States)

    Kowalski, Karren; Kelley, Brian M

    2013-01-01

    The nursing faculty shortage will have a fundamental impact on the ability to produce nurses. For most nursing schools and states, however, concerns about the relative merits of different solutions to the nursing faculty shortage are misplaced. Without significantly increased visibility and definition, accompanied by a clear public, private, and health care organization return on investment (ROI), proposing solutions to the nursing faculty shortage is at best premature and at worst irrelevant. There is simply too much competition for resources to expect that a vaguely defined and invisible problem with no rationale for increased investment will receive sufficient support from critical decision makers and constituencies. First must come problem definition, visibility, and ROI. Only then can the case be made for implementing solutions to the nursing faculty shortage.

  3. Liquid jets injected into non-uniform crossflow

    Science.gov (United States)

    Tambe, Samir

    An experimental study has been conducted with liquid jets injected transversely into a crossflow to study the effect of non-uniformities in the crossflow velocity distribution to the jet behavior. Two different non-uniform crossflows were created during this work, a shear-laden crossflow and a swirling crossflow. The shear-laden crossflow was generated by merging two independent, co-directional, parallel airstreams creating a shear mixing layer at the interface between them. The crossflow exhibited a quasi-linear velocity gradient across the height of the test chamber. By varying the velocities of the two airstreams, the sense and the slope of the crossflow velocity gradient could be changed. Particle Image Velocimetry (PIV) studies were conducted to characterize the crossflow. The parameter, UR, is defined as the ratio of the velocities of the two streams and governs the velocity gradient. A positive velocity gradient was observed for UR > 1 and a negative velocity gradient for UR Phase Doppler Particle Anemometry (PDPA) studies were conducted to study the penetration and atomization of 0.5 mm diameter water jets injected into this crossflow. The crossflow velocity gradient was observed to have a significant effect on jet penetration as well as the post breakup spray. For high UR (> 1), jet penetration increased and the Sauter Mean Diameter (SMD) distribution became more uniform. For low UR (Doppler Velocimetry (LDV) was used to study the crossflow velocities. The axial (Ux) and the tangential (Utheta) components of the crossflow velocity were observed to decrease with increasing radial distance away from the centerbody. The flow angle of the crossflow was smaller than the vane exit angle, with the difference increasing with the vane exit angle. Water jets were injected from a 0.5 mm diameter orifice located on a cylindrical centerbody. Multi-plane PIV measurements were conducted to study the penetration and droplet velocity distribution of the jets. The jets were

  4. The effect of non-uniform fuel rod temperatures on effective resonance integrals

    International Nuclear Information System (INIS)

    Reichel, A.

    1961-06-01

    The effective resonance integral for heterogeneous lattices can be reduced to the effective resonance integral for an equivalent homogeneous system with a fairly well defined error depending on lump size and geometry. This report investigates the effect of a radial parabolic temperature variation in cylindrical lumps on the equivalent homogeneous effective resonance integral. Also determined is the equivalent uniform temperature to be taken in the usual formulae to allow for non-uniform fuel rod temperature. This effective temperature is found to be T eff. = T s + 4/9 (T c - T s ) where T s and T c are the surface and central temperatures of the lump. (author)

  5. Uniformity of spherical shock wave dynamically stabilized by two successive laser profiles in direct-drive inertial confinement fusion implosions

    Energy Technology Data Exchange (ETDEWEB)

    Temporal, M., E-mail: mauro.temporal@hotmail.com [Centre de Mathématiques et de Leurs Applications, ENS Cachan and CNRS, 61 Av. du President Wilson, F-94235 Cachan Cedex (France); Canaud, B. [CEA, DIF, F-91297 Arpajon Cedex (France); Garbett, W. J. [AWE plc, Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom); Ramis, R. [ETSI Aeronáutica y del Espacio, Universidad Politécnica de Madrid, 28040 Madrid (Spain)

    2015-10-15

    The implosion uniformity of a directly driven spherical inertial confinement fusion capsule is considered within the context of the Laser Mégajoule configuration. Two-dimensional (2D) hydrodynamic simulations have been performed assuming irradiation with two laser beam cones located at 49° and 131° with respect to the axis of symmetry. The laser energy deposition causes an inward shock wave whose surface is tracked in time, providing the time evolution of its non-uniformity. The illumination model has been used to optimize the laser intensity profiles used as input in the 2D hydro-calculations. It is found that a single stationary laser profile does not maintain a uniform shock front over time. To overcome this drawback, it is proposed to use two laser profiles acting successively in time, in order to dynamically stabilize the non-uniformity of the shock front.

  6. Oil palm fresh fruit bunch ripeness classification based on rule- based expert system of ROI image processing technique results

    International Nuclear Information System (INIS)

    Alfatni, M S M; Shariff, A R M; Marhaban, M H; Shafie, S B; Saaed, O M B; Abdullah, M Z; BAmiruddin, M D

    2014-01-01

    There is a processing need for a fast, easy and accurate classification system for oil palm fruit ripeness. Such a system will be invaluable to farmers and plantation managers who need to sell their oil palm fresh fruit bunch (FFB) for the mill as this will avoid disputes. In this paper,a new approach was developed under the name of expert rules-based systembased on the image processing techniques results of thethree different oil palm FFB region of interests (ROIs), namely; ROI1 (300x300 pixels), ROI2 (50x50 pixels) and ROI3 (100x100 pixels). The results show that the best rule-based ROIs for statistical colour feature extraction with k-nearest neighbors (KNN) classifier at 94% were chosen as well as the ROIs that indicated results higher than the rule-based outcome, such as the ROIs of statistical colour feature extraction with artificial neural network (ANN) classifier at 94%, were selected for further FFB ripeness inspection system

  7. Examining Brain Morphometry Associated with Self-Esteem in Young Adults Using Multilevel-ROI-Features-Based Classification Method

    Directory of Open Access Journals (Sweden)

    Bo Peng

    2017-05-01

    Full Text Available Purpose: This study is to exam self-esteem related brain morphometry on brain magnetic resonance (MR images using multilevel-features-based classification method.Method: The multilevel region of interest (ROI features consist of two types of features: (i ROI features, which include gray matter volume, white matter volume, cerebrospinal fluid volume, cortical thickness, and cortical surface area, and (ii similarity features, which are based on similarity calculation of cortical thickness between ROIs. For each feature type, a hybrid feature selection method, comprising of filter-based and wrapper-based algorithms, is used to select the most discriminating features. ROI features and similarity features are integrated by using multi-kernel support vector machines (SVMs with appropriate weighting factor.Results: The classification performance is improved by using multilevel ROI features with an accuracy of 96.66%, a specificity of 96.62%, and a sensitivity of 95.67%. The most discriminating ROI features that are related to self-esteem spread over occipital lobe, frontal lobe, parietal lobe, limbic lobe, temporal lobe, and central region, mainly involving white matter and cortical thickness. The most discriminating similarity features are distributed in both the right and left hemisphere, including frontal lobe, occipital lobe, limbic lobe, parietal lobe, and central region, which conveys information of structural connections between different brain regions.Conclusion: By using ROI features and similarity features to exam self-esteem related brain morphometry, this paper provides a pilot evidence that self-esteem is linked to specific ROIs and structural connections between different brain regions.

  8. Non-Uniform Heat Transfer in Thermal Regenerators

    DEFF Research Database (Denmark)

    Jensen, Jesper Buch

    , a numerical model, which simulates a single-blow operation in a parallel-plate regenerator, was developed and used to model the heat transfer under various conditions. In addition to the modeling of the heat transfer, a series of experiments on passive regenerators with non-uniform, but precisely controlled....... Additionally, the experiments gave real comparative results, whereas the model to a certain degree more served to provide insight to the heat transfer processes taking place inside the regenera- tors, something that would be - if not impossible - then highly impractical to do experimentally. It has been found......This thesis presents investigations on the heat transfer in complex heat ex- changers in general and in regenerative heat exchangers (regenerators) in par- ticular. The motivation for this work is a result of inconsistencies obeserved in the results from a series of experiments on active magnetic...

  9. Determination of the axial thermal neutron flux non-uniform factor in the MNSR inner irradiation capsule

    International Nuclear Information System (INIS)

    Khattab, K.; Ghazi, N.; Omar, H.

    2007-01-01

    A 3-D neutronic model, using the WIMSD4 and CITATION codes, for the Syrian Miniature Neutron source Reactor (MNSR) is used to calculate the axial thermal neutron flux non-uniform factor in the inner irradiation capsule. The calculated result is 4%. A copper wire is used to measure the axial thermal neutron flux non-uniform factor in the inner irradiation capsule to be compared with the calculated result. The measured result is 5%. Good agreement between the measured and calculated results is obtained. (author)

  10. Determination of the axial thermal neutron flux non-uniform factor in the MNSR inner irradiation capsule

    International Nuclear Information System (INIS)

    Khattab, K.; Ghazi, N.; Omar, H.

    2007-01-01

    A 3-D neutronic model, using the WIMSD4 and CITATION codes, for the Syrian Miniature Neutron Source Reactor (MNSR) is used to calculate the axial thermal neutron flux non-uniform factor in the inner irradiation capsule. The calculated result is 4%. A copper wire is used to measure the axial thermal neutron flux non-uniform factor in the inner irradiation capsule to be compared with the calculated result. The measured result is 5%. Good agreement between the measured and calculated results is obtained

  11. Bone-Marrow Stem-Cell Survival in the Non-Uniformly Exposed Mammal

    Energy Technology Data Exchange (ETDEWEB)

    Bond, V. P.; Robinson, C. V. [Brookhaven National Laboratory, Medical Research Center, Upton, Long Island, NY (United States)

    1967-07-15

    For comparison of the effectiveness of non-uniform versus uniform irradiations in causing haematological death in mammals, a model of the irradiated haemopoietic system has been proposed. The essential features of this model are: (1) that different parts of the haemopoietic system have numbers of stem cells which are proportioned to the amounts of active marrow in those parts as measured by {sup 59}Fe uptake, (2) that stem cells in the different parts are subject to the, same dose-survival relationship, and (3) that survival of the animal depends on survival of a critical fraction of the total number of stem cells independent of their distribution among the parts of the total marrow mass. To apply this model one needs to know: (a) the relative {sup 59}Fe uptakes of the different parts of the haemopoietic system, (b) the doses delivered to those parts by each of the exposures to be compared, and (c) the dose-survival curve applicable to the stem cells. From these one can calculate the fraction of stem cells surviving each exposure. In a preliminary communication the applicability of the model was investigated using data obtained entirely from the literature. Additional data, particularly on bone-marrow distribution, have since been obtained and are included here. The primary object of the present paper is to test further the validity of the above 'stem-cell survival model'. Data on bilateral (essentially uniform) versus unilateral and non-uniform rotational exposures in mammals are examined with respect to the surviving fraction of stem cells at the LD{sub 50/30} day dose level. Although an adequate test is not possible at present for lack of a full set of data in any one species, a partial test indicates compatibility with data for dogs and rats. Other possible mortality determinants such as doses or exposures at entrance, midline or exit, or the gram-rads or average dose to the marrow, appear to be less useful than the critical stem-cell survival fraction.

  12. Impact of Non-Uniformity in Light Collection on the Energy Resolution of the PANDA Electromagnetic Calorimeter at Photon Energies Below 1 GeV

    Science.gov (United States)

    Diehl, Stefan; Brinkmann, Kai-Thomas; Drexler, Peter; Dormenev, Valery; Novotny, Rainer W.; Rosenbaum, Christoph; Zaunick, Hans-Georg; PANDA-Collaboration

    2017-11-01

    The electromagnetic calorimeter (EMC) of the PANDA detector at the future FAIR facility comprises more than 15,000 lead tungstate (PWO) crystals. The barrel part will consist of 11 crystal geometries with different degree of tapering, which causes a non-uniformity in light collection as an interplay between the focusing and the internal absorption of the light. For the most tapered crystals the detected light is enhanced by 40%, if the scintillation process is created in the front part of the crystal. Due to the shower development and its fluctuations the non-uniformity leads to a reduction of the energy resolution. To reduce this effect, one lateral crystal side face has been de-polished to a roughness of 0.3 μm. Measurements confirm an increase of the light yield in the rear part of the crystal. In contrast, only a slight decrease can be observed in the front part. The overall non-uniformity is significantly reduced below 5%. This paper will discuss the experimental studies based on GEANT4 and optical simulations to understand the impact of a de-polished side face on the light collection. For consequences on the future performance, a 3×3 sub-array of de-polished crystals was directly studied using a tagged photon beam in the energy range from 50 MeV up to 800 MeV, respectively, performed at the tagged photon facility at MAMI, Mainz. The comparison to an array composed of polished crystals confirms a significant improvement of the constant term of the energy resolution from above 2 % down to 0.5 % and only a small increase of the statistical term. The results can be reproduced in GEANT4 simulations.

  13. Phase transitions in local equation-of-state approximation and anomalies of spatial charge profiles in non-uniform plasma

    Science.gov (United States)

    Chigvintsev, A. Yu; Zorina, I. G.; Noginova, L. Yu; Iosilevskiy, I. L.

    2018-01-01

    Impressive appearance of discontinuities in equilibrium spatial charge profiles in non-uniform Coulomb systems is under discussions in wide number of thermoelectrostatics problems. Such discontinuities are considered as peculiar micro-level manifestation of phase transitions and intrinsic macro-level non-ideality effects in local equation of state (EOS), which should be used for description of non-ideal ionic subsystem in frames of local-density (or “pseudofluid”, or “jellium” etc) approximation. Such discontinuities were discussed already by the authors for electronic subsystems. Special emphasis is made in present paper on the mentioned above non-ideality effects in non-uniform ionic subsystems, such as micro-ions profile within screening “cloud” around macro-ion in complex (dusty, colloid etc) plasmas, equilibrium charge profile in ionic traps or (and) in the neighborhood vicinity of “charged wall” etc). Multiphase EOS for simplified ionic model of classical charged hard spheres on uniformly compressible electrostatic compensating background was constructed and several illustrative examples of discussed discontinuous ionic profiles were calculated.

  14. Quantum ratchet effect in a time non-uniform double-kicked model

    Science.gov (United States)

    Chen, Lei; Wang, Zhen-Yu; Hui, Wu; Chu, Cheng-Yu; Chai, Ji-Min; Xiao, Jin; Zhao, Yu; Ma, Jin-Xiang

    2017-07-01

    The quantum ratchet effect means that the directed transport emerges in a quantum system without a net force. The delta-kicked model is a quantum Hamiltonian model for the quantum ratchet effect. This paper investigates the quantum ratchet effect based on a time non-uniform double-kicked model, in which two flashing potentials alternately act on a particle with a homogeneous initial state of zero momentum, while the intervals between adjacent actions are not equal. The evolution equation of the state of the particle is derived from its Schrödinger equation, and the numerical method to solve the evolution equation is pointed out. The results show that quantum resonances can induce the ratchet effect in this time non-uniform double-kicked model under certain conditions; some quantum resonances, which cannot induce the ratchet effect in previous models, can induce the ratchet effect in this model, and the strengths of the ratchet effect in this model are stronger than those in previous models under certain conditions. These results enrich people’s understanding of the delta-kicked model, and provides a new optional scheme to control the quantum transport of cold atoms in experiment.

  15. Tumour control probability (TCP) for non-uniform activity distribution in radionuclide therapy

    International Nuclear Information System (INIS)

    Uusijaervi, Helena; Bernhardt, Peter; Forssell-Aronsson, Eva

    2008-01-01

    Non-uniform radionuclide distribution in tumours will lead to a non-uniform absorbed dose. The aim of this study was to investigate how tumour control probability (TCP) depends on the radionuclide distribution in the tumour, both macroscopically and at the subcellular level. The absorbed dose in the cell nuclei of tumours was calculated for 90 Y, 177 Lu, 103m Rh and 211 At. The radionuclides were uniformly distributed within the subcellular compartment and they were uniformly, normally or log-normally distributed among the cells in the tumour. When all cells contain the same amount of activity, the cumulated activities required for TCP = 0.99 (A-tilde TCP=0.99 ) were 1.5-2 and 2-3 times higher when the activity was distributed on the cell membrane compared to in the cell nucleus for 103m Rh and 211 At, respectively. TCP for 90 Y was not affected by different radionuclide distributions, whereas for 177 Lu, it was slightly affected when the radionuclide was in the nucleus. TCP for 103m Rh and 211 At were affected by different radionuclide distributions to a great extent when the radionuclides were in the cell nucleus and to lesser extents when the radionuclides were distributed on the cell membrane or in the cytoplasm. When the activity was distributed in the nucleus, A-tilde TCP=0.99 increased when the activity distribution became more heterogeneous for 103m Rh and 211 At, and the increase was large when the activity was normally distributed compared to log-normally distributed. When the activity was distributed on the cell membrane, A-tilde TCP=0.99 was not affected for 103m Rh and 211 At when the activity distribution became more heterogeneous. A-tilde TCP=0.99 for 90 Y and 177 Lu were not affected by different activity distributions, neither macroscopic nor subcellular

  16. A method to estimate the fractional fat volume within a ROI of a breast biopsy for WAXS applications: Animal tissue evaluation

    International Nuclear Information System (INIS)

    Tang, Robert Y.; McDonald, Nancy; Laamanen, Curtis; LeClair, Robert J.

    2014-01-01

    Purpose: To develop a method to estimate the mean fractional volume of fat (ν ¯ fat ) within a region of interest (ROI) of a tissue sample for wide-angle x-ray scatter (WAXS) applications. A scatter signal from the ROI was obtained and use of ν ¯ fat in a WAXS fat subtraction model provided a way to estimate the differential linear scattering coefficient μ s of the remaining fatless tissue. Methods: The efficacy of the method was tested using animal tissue from a local butcher shop. Formalin fixed samples, 5 mm in diameter 4 mm thick, were prepared. The two main tissue types were fat and meat (fibrous). Pure as well as composite samples consisting of a mixture of the two tissue types were analyzed. For the latter samples, ν fat for the tissue columns of interest were extracted from corresponding pixels in CCD digital x-ray images using a calibration curve. The means ν ¯ fat were then calculated for use in a WAXS fat subtraction model. For the WAXS measurements, the samples were interrogated with a 2.7 mm diameter 50 kV beam and the 6° scattered photons were detected with a CdTe detector subtending a solid angle of 7.75 × 10 −5 sr. Using the scatter spectrum, an estimate of the incident spectrum, and a scatter model, μ s was determined for the tissue in the ROI. For the composite samples, a WAXS fat subtraction model was used to estimate the μ s of the fibrous tissue in the ROI. This signal was compared to μ s of fibrous tissue obtained using a pure fibrous sample. Results: For chicken and beef composites, ν ¯ fat =0.33±0.05 and 0.32 ± 0.05, respectively. The subtractions of these fat components from the WAXS composite signals provided estimates of μ s for chicken and beef fibrous tissue. The differences between the estimates and μ s of fibrous obtained with a pure sample were calculated as a function of the momentum transfer x. A t-test showed that the mean of the differences did not vary from zero in a statistically significant way thereby

  17. Induced charge of spherical dust particle on plasma-facing wall in non-uniform electric field

    International Nuclear Information System (INIS)

    Tomita, Y.; Smirnov, R.; Zhu, S.

    2005-01-01

    Induced charge of a spherical dust particle on a plasma-facing wall is investigated analytically, where non-uniform electric field is applied externally. The one-dimensional non-uniform electrostatic potential is approximated by the polynomial of the normal coordinate toward the wall. The bipolar coordinate is introduced to solve the Laplace equation of the induced electrostatic potential. The boundary condition at the dust surface determines the unknown coefficients of the general solution of the Laplace equation for the induced potential. From the obtained potential the surface induced charge can be calculated. This result allows estimating the effect of the surrounding plasma, which shields the induced charge. (author)

  18. Land-use change and managed aquifer recharge effects on the hydrogeochemistry of two contrasting atoll island aquifers, Roi-Namur Island, Republic of the Marshall Islands

    Science.gov (United States)

    Hejazian, Mehrdad; Gurdak, Jason J.; Swarzenski, Peter W.; Odigie, Kingsley; Storlazzi, Curt

    2017-01-01

    Freshwater resources on low-lying atoll islands are highly vulnerable to climate change and sea-level rise. In addition to rainwater catchment, groundwater in the freshwater lens is a critically important water resource on many atoll islands, especially during drought. Although many atolls have high annual rainfall rates, dense natural vegetation and high evapotranspiration rates can limit recharge to the freshwater lens. Here we evaluate the effects of land-use/land-cover change and managed aquifer recharge on the hydrogeochemistry and supply of groundwater on Roi-Namur Island, Republic of the Marshall Islands. Roi-Namur is an artificially conjoined island that has similar hydrogeology on the Roi and Namur lobes, but has contrasting land-use/land-cover and managed aquifer recharge only on Roi. Vegetation removal and managed aquifer recharge operations have resulted in an estimated 8.6 x 105 m3 of potable groundwater in the freshwater lens on Roi, compared to only 1.6 x 104 m3 on Namur. We use groundwater samples from a suite of 33 vertically nested monitoring wells, statistical testing, and geochemical modeling using PHREEQC to show that the differences in land-use/land-cover and managed aquifer recharge on Roi and Namur have a statistically significant effect on several groundwater-quality parameters and the controlling geochemical processes. Results also indicate a seven-fold reduction in the dissolution of carbonate rock in the freshwater lens and overlying vadose zone of Roi compared to Namur. Mixing of seawater and the freshwater lens is a more dominant hydrogeochemical process on Roi because of the greater recharge and flushing of the aquifer with freshwater as compared to Namur. In contrast, equilibrium processes and dissolution-precipitation non-equilibrium reactions are more dominant on Namur because of the longer residence times relative to the rate of geochemical reactions. Findings from Roi-Namur Island support selective land-use/land-cover change and

  19. Efficient design of multiplier-less digital channelizers using recombination non-uniform filter banks

    Directory of Open Access Journals (Sweden)

    Shaeen Kalathil

    2018-01-01

    Full Text Available A novel approach for the efficient realization of digital channelizers in software defined radios using recombination filter banks is proposed in this paper. Digital channelizer is the core of software defined radio. Computationally efficient design supporting multiple channels with different bandwidths and low complexity are inevitable requirements for the digital channelizers. Recombination filter banks method is used to obtain non-uniform filter banks with rational sampling factors, using a two stage structure. It consists of a uniform filter bank and trans-multiplexer. In this work, the uniform filter bank and trans-multiplexer are designed using cosine modulated filter banks. The prototype filter design is made simple, efficient and fast, using window method. The multiplier-less realization of recombination filter banks in the canonic signed digit space using nature inspired optimization algorithms, results in reduced implementation complexity.

  20. Image restoration from non-uniform magnetic field influence for direct Fourier NMR imaging

    International Nuclear Information System (INIS)

    Sekihara, K.; Kuroda, M.; Kohno, H.

    1984-01-01

    A new technique is proposed for NMR image restoration from the influence of main magnetic field non-uniformities. This technique is applicable to direct Fourier NMR imaging. The mathematical basis and details of this technique are fully described. Modification to include image restoration from non-linear field gradient influence is also presented. Computer simulation demonstrates the effectiveness of this technique for both Fourier zeugmatography and spin-warp imaging. (author)

  1. Conversion of isotropic fluorescence into a long-range non-diverging beam

    Science.gov (United States)

    Zhang, Douguo; Zhu, Liangfu; Chen, Junxue; Wang, Ruxue; Wang, Pei; Ming, Hai; Badugu, Ramachandram; Rosenfeld, Mary; Zhan, Qiwen; Kuang, Cuifang; Liu, Xu; Lakowicz, Joseph R.

    2018-04-01

    Fluorescent samples typically emit isotropically in all directions. Large lenses and other optical components are needed to capture a significant fraction of the emission, and complex confocal microscopes are required for high resolution focal-plane imaging. It is known that Bessel beams have remarkable properties of being able to travel over long distances, over 1000 times the wavelength, without diverging, and hence are called non-diffracting beams. In previous reports the Bessel beams were formed by an incident light source, typically with plane-wave illumination on a circular aperture. It was not known if Bessel beams could form from fluorescent light sources. We demonstrate transformation of the emission from fluorescent polystyrene spheres (FPS) into non-diverging beams which propagate up to 130 mm (13 cm) along the optical axis with a constant diameter. This is accomplished using a planar metal film, with no nanoscale features in the X-Y plane, using surface plasmon-coupled emission. Using samples which contain many FPS in the field-of-view, we demonstrate that an independent Bessel beam can be generated from any location on the metal film. The extremely long non-diffracted propagation distances, and self-healing properties of Bessel beams, offer new opportunities in fluorescence sensing and imaging.

  2. Effect of disjoining pressure in a thin film equation with non-uniform forcing

    KAUST Repository

    MOULTON, D. E.; LEGA, J.

    2013-01-01

    We explore the effect of disjoining pressure on a thin film equation in the presence of a non-uniform body force, motivated by a model describing the reverse draining of a magnetic film. To this end, we use a combination of numerical investigations

  3. Attention to detail helps Clarian measure ROI.

    Science.gov (United States)

    2007-01-01

    Clarian Health takes a risk and embarks on a branding strategy. Taking a multi-integrated approach, with The Heavy Weights in Indianapolis, Clarian started managing its marketing by tracking return on investment (ROI) and making the most of a CRM database. In a groundbreaking approach, it found that it was actually able to turn its marketing effort into a money-maker, leading higher-ups to see its outreach efforts as necessity.

  4. Influence of ROI selection on Resting Functional Connectivity: An Individualized Approach for Resting fMRI Analysis

    Directory of Open Access Journals (Sweden)

    William Seunghyun Sohn

    2015-08-01

    Full Text Available The differences in how our brain is connected are often thought to reflect the differences in our individual personalities and cognitive abilities. Individual differences in brain connectivity has long been recognized in the neuroscience community however it has yet to manifest itself in the methodology of resting state analysis. This is evident as previous studies use the same region of interest (ROIs for all subjects. In this paper we demonstrate that the use of ROIs which are standardized across individuals leads to inaccurate calculations of functional connectivity. We also show that this problem can be addressed by taking an individualized approach by using subject-specific ROIs. Finally we show that ROI selection can affect the way we interpret our data by showing different changes in functional connectivity with ageing.

  5. Atomic layer deposition of HfO{sub 2} on graphene through controlled ion beam treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Seok [School of Advanced Materials Science and Engineering, Sungkyunkwan University, 2066 Seobu-ro, Jangan-gu, Suwon-si, Gyeonggi-do 16419 (Korea, Republic of); Oh, Il-Kwon; Jung, Hanearl; Kim, Hyungjun [School of Electrical and Electronics Engineering, Yonsei University, 50 Yonsei Ro, Seodaemun-gu, Seoul 120-749 (Korea, Republic of); Yeom, Geun Young, E-mail: knam1004@dju.kr, E-mail: gyyeom@skku.edu [School of Advanced Materials Science and Engineering, Sungkyunkwan University, 2066 Seobu-ro, Jangan-gu, Suwon-si, Gyeonggi-do 16419 (Korea, Republic of); SKKU Advanced Institute of Nano Technology (SAINT), Sungkyunkwan University, 2066 Seobu-ro, Jangan-gu, Suwon-si, Gyeonggi-do 16419 (Korea, Republic of); Kim, Kyong Nam, E-mail: knam1004@dju.kr, E-mail: gyyeom@skku.edu [School of Advanced Materials Science and Engineering, Daejeon University, Yongun-dong, Dong-gu, Daejeon 34520 (Korea, Republic of)

    2016-05-23

    The polymer residue generated during the graphene transfer process to the substrate tends to cause problems (e.g., a decrease in electron mobility, unwanted doping, and non-uniform deposition of the dielectric material). In this study, by using a controllable low-energy Ar{sup +} ion beam, we cleaned the polymer residue without damaging the graphene network. HfO{sub 2} grown by atomic layer deposition on graphene cleaned using an Ar{sup +} ion beam showed a dense uniform structure, whereas that grown on the transferred graphene (before Ar{sup +} ion cleaning) showed a non-uniform structure. A graphene–HfO{sub 2}–metal capacitor fabricated by growing 20-nm thick HfO{sub 2} on graphene exhibited a very low leakage current (<10{sup −11} A/cm{sup 2}) for Ar{sup +} ion-cleaned graphene, whereas a similar capacitor grown using the transferred graphene showed high leakage current.

  6. The influence of printing substrate on macro non-uniformity and line reproduction quality of imprints printed with electrophotographic process

    Directory of Open Access Journals (Sweden)

    Đorđe Vujčić

    2016-12-01

    Full Text Available Print quality is very important for every printing technique. It depends on many different quality attributes. This research included analysis of macro non-uniformities and line reproduction. 16 different paper substrates printed by electrophotographic process were analyzed. They were separated in two groups: coated and uncoated papers. Analysis of macro non-uniformity showed that print mottle has lower values when printed on coated papers than on uncoated papers. Line reproduction analysis showed that the toner spreaded, during melting and fixation, on line edges for both types of paper. According to these results it can be concluded that paper substrate affects the macro non-uniformity and line reproduction, thus overall print quality.

  7. Improvement of laser irradiation uniformity in GEKKO XII glass laser system

    International Nuclear Information System (INIS)

    Miyanaga, Noriaki; Matsuoka, Shinichi; Ando, Akinobu; Amano, Shinji; Nakatsuka, Masahiro; Kanabe, Tadashi; Jitsuno, Takahisa; Nakai, Sadao

    1995-01-01

    The uniform laser irradiation is one of key issues in the direct drive laser fusion research. The several key technologies for the uniform laser irradiation are reported. This paper includes the uniformity performance as a result of the introduction of the random phase plate, the partially coherent light and the beam smoothing by spectral dispersion into the New Gekko XI glass laser system. Finally the authors summarize the overall irradiation uniformity on the spherical target surface by considering the power imbalance effect. The technologies developed for the beam smoothing and the power balance control enable them to achieve the irradiation nonuniformities of around 1% level for a foot pulse and of a few % for a main drive pulse, respectively

  8. Beam halo in high-intensity beams

    International Nuclear Information System (INIS)

    Wangler, T.P.

    1993-01-01

    In space-charge dominated beams the nonlinear space-charge forces produce a filamentation pattern, which in projection to the 2-D phase spaces results in a 2-component beam consisting of an inner core and a diffuse outer halo. The beam-halo is of concern for a next generation of cw, high-power proton linacs that could be applied to intense neutron generators for nuclear materials processing. The author describes what has been learned about beam halo and the evolution of space-charge dominated beams using numerical simulations of initial laminar beams in uniform linear focusing channels. Initial results are presented from a study of beam entropy for an intense space-charge dominated beam

  9. The development of criteria for limiting the non-uniform irradiation of skin: the rationale for a study of non-stochastic effects

    International Nuclear Information System (INIS)

    Wells, J.; Charles, M.W.

    1979-06-01

    Recent recommendations of the ICRP (1977) provide little guidance for the treatment of non-uniform skin exposures such as those which may occur as the result of contamination with radioactive particulates. This lack of guidance is due to a paucity of data regarding biological effects in this area. A rationale is presented for the study of the early (non-stochastic) effects of non-uniform skin irradiation. As a basis for the presentation of this rationale a framework is provided by a resume of basic biology of the skin and a review of previous experimental work in this field. Animal experiments, which are being carried out in collaboration with specialist university groups, are described both in terms of broad concept and experimental detail. The aim is to provide biological data which can provide guidance in radiological protection situations. (author)

  10. Research of non-uniform multiple hole straighteners for measuring flow rate

    International Nuclear Information System (INIS)

    Wen Duanzhong; Zhong Dezhen; Cai Zhuti

    1989-01-01

    Standard throttling flowmeters are widely used in process flow rate measurement. Enough upstream and downstream straight pipe are necessary for it. If not, the error will be increased. Mounting straightener is an effective way for solving this problem. Advantages of non-uniform multiple hole straighteners studied by authors are good results for straighting, simple in Structure, convenient for mounting and low cost. So it can be popularized in many applications

  11. An Ad Hoc Adaptive Hashing Technique forNon-Uniformly Distributed IP Address Lookup in Computer Networks

    Directory of Open Access Journals (Sweden)

    Christopher Martinez

    2007-02-01

    Full Text Available Hashing algorithms long have been widely adopted to design a fast address look-up process which involves a search through a large database to find a record associated with a given key. Hashing algorithms involve transforming a key inside each target data to a hash value hoping that the hashing would render the database a uniform distribution with respect to this new hash value. The close the final distribution is to uniform, the less search time would be required when a query is made. When the database is already key-wise uniformly distributed, any regular hashing algorithm, such as bit-extraction, bit-group XOR, etc., would easily lead to a statistically perfect uniform distribution after the hashing. On the other hand, if records in the database are instead not uniformly distributed as in almost all known practical applications, then even different regular hash functions would lead to very different performance. When the target database has a key with a highly skewed distributed value, performance delivered by regular hashing algorithms usually becomes far from desirable. This paper aims at designing a hashing algorithm to achieve the highest probability in leading to a uniformly distributed hash result from a non-uniformly distributed database. An analytical pre-process on the original database is first performed to extract critical information that would significantly benefit the design of a better hashing algorithm. This process includes sorting on the bits of the key to prioritize the use of them in the XOR hashing sequence, or in simple bit extraction, or even a combination of both. Such an ad hoc hash design is critical to adapting to all real-time situations when there exists a changing (and/or expanding database with an irregular non-uniform distribution. Significant improvement from simulation results is obtained in randomly generated data as well as real data.

  12. Low-Cost Small Satellite Atmospheric Rotating Solar Occultation Imager (ROI)

    Data.gov (United States)

    National Aeronautics and Space Administration — Utilizing a unique, new occultation technique involving imaging, the ROI concept will meet or exceed the quality of SAGE measurements at a small fraction of the...

  13. Buckling of thin-walled beams under concentrated transverse loading

    NARCIS (Netherlands)

    Menken, C.M.; Erp, van G.M.; Krupta, V.; Drdacky, M.

    1991-01-01

    The transversely loaded thin-walled beam under a non-uniform bending moment forms an example of the detrimental influence that a local effect may have on the overall behaviour. The local effect is the plate buckling in the region of maximum bending moment. The overall behaviour is the

  14. Supersonic Mass Flux Measurements via Tunable Diode Laser Absorption and Non-Uniform Flow Modeling

    Science.gov (United States)

    Chang, Leyen S.; Strand, Christopher L.; Jeffries, Jay B.; Hanson, Ronald K.; Diskin, Glenn S.; Gaffney, Richard L.; Capriotti, Diego P.

    2011-01-01

    Measurements of mass flux are obtained in a vitiated supersonic ground test facility using a sensor based on line-of-sight (LOS) diode laser absorption of water vapor. Mass flux is determined from the product of measured velocity and density. The relative Doppler shift of an absorption transition for beams directed upstream and downstream in the flow is used to measure velocity. Temperature is determined from the ratio of absorption signals of two transitions (lambda(sub 1)=1349 nm and lambda(sub 2)=1341.5 nm) and is coupled with a facility pressure measurement to obtain density. The sensor exploits wavelength-modulation spectroscopy with second-harmonic detection (WMS-2f) for large signal-to-noise ratios and normalization with the 1f signal for rejection of non-absorption related transmission fluctuations. The sensor line-of-sight is translated both vertically and horizontally across the test section for spatially-resolved measurements. Time-resolved measurements of mass flux are used to assess the stability of flow conditions produced by the facility. Measurements of mass flux are within 1.5% of the value obtained using a facility predictive code. The distortion of the WMS lineshape caused by boundary layers along the laser line-of-sight is examined and the subsequent effect on the measured velocity is discussed. A method for correcting measured velocities for flow non-uniformities is introduced and application of this correction brings measured velocities within 4 m/s of the predicted value in a 1630 m/s flow.

  15. On the Time Variation of Dust Extinction and Gas Absorption for Type Ia Supernovae Observed Through Non-uniform Interstellar Medium

    Science.gov (United States)

    Huang, Xiaosheng; Aldering, Gregory; Biederman, Moriah; Herger, Brendan

    2018-01-01

    For Type Ia supernovae (SNe Ia) observed through a non-uniform interstellar medium (ISM) in its host galaxy, we investigate whether the non-uniformity can cause observable time variations in dust extinction and in gas absorption due to the expansion of the SN photosphere with time. We show that, owing to the steep spectral index of the ISM density power spectrum, sizable density fluctuation amplitudes at the length scale of typical ISM structures (>~ 10 pc) will translate to much smaller fluctuations on the scales of a SN photosphere. Therefore the typical amplitude of time variation due to non-uniform ISM, of absorption equivalent widths and of extinction, would be small. As a result, we conclude that non-uniform ISM density should not impact cosmology measurements based on SNe Ia. We apply our predictions based on the ISM density power law power spectrum to the observations of two highly reddened SNe Ia, SN 2012cu and SN 2014J.

  16. Finite element analysis of heating a non-mixed liquid with non-uniform solar flux through semi-transparent medium

    International Nuclear Information System (INIS)

    Safdari, Y.B.; Sirivatch Shimpalee

    2000-01-01

    It has been shown in an application [1-3), in a solar flux heating of a liquid through a semi-transparent medium, that the far side of the medium receiving solar radiation achieves a higher temperature than the side receiving radiation. In this work, a two-dimensional transient finite element analysis of concentrated solo flux heating of a non-mixed liquid through a semi-transparent medium (such as glass) is carried out. The radiation heat flux is provided by a paraboloidal concentrator which focuses a non-uniform flux on the receiver. Realistic boundary conditions are considered to analyse the heat transfer problem to study the transient temperature distribution in the medium. The effects of a non-mixed liquid and a non-uniform flux show dramatic differences between the present work and the previous works [1-31. A non-mixed liquid causes greater temperature difference in the glass in both radial and axial direction than a mixed liquid used in the previous analysis. Therminol-55 is used as heated liquid for lower flux case, and sodium is used for high flux. The effect of the conductivity difference between the two liquids is studied. Results show that in the case of Therminol-55, the temperature of the liquid-side glass is much higher than that of the sodium case. The temperature distribution will be used to analyse the thermal stresses in the glass to see if fracture will occurs [4) in the glass. (Author)

  17. A multilevel-ROI-features-based machine learning method for detection of morphometric biomarkers in Parkinson's disease.

    Science.gov (United States)

    Peng, Bo; Wang, Suhong; Zhou, Zhiyong; Liu, Yan; Tong, Baotong; Zhang, Tao; Dai, Yakang

    2017-06-09

    Machine learning methods have been widely used in recent years for detection of neuroimaging biomarkers in regions of interest (ROIs) and assisting diagnosis of neurodegenerative diseases. The innovation of this study is to use multilevel-ROI-features-based machine learning method to detect sensitive morphometric biomarkers in Parkinson's disease (PD). Specifically, the low-level ROI features (gray matter volume, cortical thickness, etc.) and high-level correlative features (connectivity between ROIs) are integrated to construct the multilevel ROI features. Filter- and wrapper- based feature selection method and multi-kernel support vector machine (SVM) are used in the classification algorithm. T1-weighted brain magnetic resonance (MR) images of 69 PD patients and 103 normal controls from the Parkinson's Progression Markers Initiative (PPMI) dataset are included in the study. The machine learning method performs well in classification between PD patients and normal controls with an accuracy of 85.78%, a specificity of 87.79%, and a sensitivity of 87.64%. The most sensitive biomarkers between PD patients and normal controls are mainly distributed in frontal lobe, parental lobe, limbic lobe, temporal lobe, and central region. The classification performance of our method with multilevel ROI features is significantly improved comparing with other classification methods using single-level features. The proposed method shows promising identification ability for detecting morphometric biomarkers in PD, thus confirming the potentiality of our method in assisting diagnosis of the disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Numerical Prediction of the Impact of Non-Uniform Leading Edge Coatings On the Aerodynamic Performance of Compressor Airfoils

    National Research Council Canada - National Science Library

    Elmstrom, Michael

    2004-01-01

    A computational fluid dynamic (CFD) investigation is presented that provides predictions of the aerodynamic impact of uniform and non-uniform coatings applied to the leading edge of a compressor airfoil in a cascade. Using a NACA 65(12...

  19. Non-uniformly sampled grids in double pole coordinate system for freeform reflector construction

    Science.gov (United States)

    Ma, Donglin; Pacheco, Shaun; Feng, Zexin; Liang, Rongguang

    2015-08-01

    We propose a new method to design freeform reflectors by nonuniformly sampling the source intensity distribution in double pole coordinate system. In double pole coordinate system, there is no pole for the whole hemisphere because both poles of the spherical coordinate system are moved to southernmost point of the sphere and overlapped together. With symmetric definition of both angular coordinates in the modified double pole coordinate system, a better match between the source intensity distribution and target irradiance distribution can be achieved for reflectors with large acceptance solid angle, leading to higher light efficiency and better uniformity on the target surface. With non-uniform sampling of the source intensity, we can design circular freeform reflector to obtain uniform rectangular illumination pattern. Aided by the feedback optimization, the freeform reflector can achieve the collection efficiency for ideal point source over 0.7 and relative standard deviation (RSD) less than 0.1.

  20. Thermal stability improvement of a multiple finger power SiGe heterojunction bipolar transistor under different power dissipations using non-uniform finger spacing

    International Nuclear Information System (INIS)

    Chen Liang; Zhang Wan-Rong; Jin Dong-Yue; Shen Pei; Xie Hong-Yun; Ding Chun-Bao; Xiao Ying; Sun Bo-Tao; Wang Ren-Qing

    2011-01-01

    A method of non-uniform finger spacing is proposed to enhance thermal stability of a multiple finger power SiGe heterojunction bipolar transistor under different power dissipations. Temperature distribution on the emitter fingers of a multi-finger SiGe heterojunction bipolar transistor is studied using a numerical electro-thermal model. The results show that the SiGe heterojunction bipolar transistor with non-uniform finger spacing has a small temperature difference between fingers compared with a traditional uniform finger spacing heterojunction bipolar transistor at the same power dissipation. What is most important is that the ability to improve temperature non-uniformity is not weakened as power dissipation increases. So the method of non-uniform finger spacing is very effective in enhancing the thermal stability and the power handing capability of power device. Experimental results verify our conclusions. (interdisciplinary physics and related areas of science and technology)

  1. Distribution uniformity of laser-accelerated proton beams

    Science.gov (United States)

    Zhu, Jun-Gao; Zhu, Kun; Tao, Li; Xu, Xiao-Han; Lin, Chen; Ma, Wen-Jun; Lu, Hai-Yang; Zhao, Yan-Ying; Lu, Yuan-Rong; Chen, Jia-Er; Yan, Xue-Qing

    2017-09-01

    Compared with conventional accelerators, laser plasma accelerators can generate high energy ions at a greatly reduced scale, due to their TV/m acceleration gradient. A compact laser plasma accelerator (CLAPA) has been built at the Institute of Heavy Ion Physics at Peking University. It will be used for applied research like biological irradiation, astrophysics simulations, etc. A beamline system with multiple quadrupoles and an analyzing magnet for laser-accelerated ions is proposed here. Since laser-accelerated ion beams have broad energy spectra and large angular divergence, the parameters (beam waist position in the Y direction, beam line layout, drift distance, magnet angles etc.) of the beamline system are carefully designed and optimised to obtain a radially symmetric proton distribution at the irradiation platform. Requirements of energy selection and differences in focusing or defocusing in application systems greatly influence the evolution of proton distributions. With optimal parameters, radially symmetric proton distributions can be achieved and protons with different energy spread within ±5% have similar transverse areas at the experiment target. Supported by National Natural Science Foundation of China (11575011, 61631001) and National Grand Instrument Project (2012YQ030142)

  2. Development of a non-contact diagnostic tool for high power lasers

    Science.gov (United States)

    Simmons, Jed A.; Guttman, Jeffrey L.; McCauley, John

    2016-03-01

    High power lasers in excess of 1 kW generate enough Rayleigh scatter, even in the NIR, to be detected by silicon based sensor arrays. A lens and camera system in an off-axis position can therefore be used as a non-contact diagnostic tool for high power lasers. Despite the simplicity of the concept, technical challenges have been encountered in the development of an instrument referred to as BeamWatch. These technical challenges include reducing background radiation, achieving high signal to noise ratio, reducing saturation events caused by particulates crossing the beam, correcting images to achieve accurate beam width measurements, creating algorithms for the removal of non-uniformities, and creating two simultaneous views of the beam from orthogonal directions. Background radiation in the image was reduced by the proper positioning of the back plane and the placement of absorbing materials on the internal surfaces of BeamWatch. Maximizing signal to noise ratio, important to the real-time monitoring of focus position, was aided by increasing lens throughput. The number of particulates crossing the beam path was reduced by creating a positive pressure inside BeamWatch. Algorithms in the software removed non-uniformities in the data prior to generating waist width, divergence, BPP, and M2 results. A dual axis version of BeamWatch was developed by the use of mirrors. By its nature BeamWatch produced results similar to scanning slit measurements. Scanning slit data was therefore taken and compared favorably with BeamWatch results.

  3. Internal-wave reflection from uniform slopes: higher harmonics and Coriolis effects

    Directory of Open Access Journals (Sweden)

    T. Gerkema

    2006-01-01

    Full Text Available Weakly nonlinear reflection of internal waves from uniform slopes produces higher harmonics and mean fields; the expressions are here derived for constant stratification and with Coriolis effects fully included, i.e. the horizontal component of the earth rotation vector (referred to as 'non-traditional'' is taken into account. Uniformity in one of the horizontal directions is assumed. It is shown that solutions can be as readily derived with as without ; hence there is no need to make the so-called Traditional Approximation. Examples of reflecting internal-wave beams are presented for super-inertial, inertial and sub-inertial frequencies. The problem of resonant and non-resonant forcing of the second harmonic is studied for single plane waves; unlike under the Traditional Approximation, the problem of reflection from a horizontal bottom no longer forms a singular case. Non-traditional effects are favourable to resonant forcing at near-tidal rather than near-inertial frequencies, and generally increase the intensity of the second harmonic. Strong stratification tends to suppress non-traditional effects, but a near-total suppression is only attained for high values of stratification that are characteristic of the seasonal thermocline; in most parts of the ocean, non-traditional effects can therefore be expected to be important.

  4. Pondermotive absorption of a short intense laser pulse in a non-uniform plasma

    Energy Technology Data Exchange (ETDEWEB)

    Andreev, A A; Platonov, K Yu [Inst. for Laser Physics, SC ` Vavilov State Optical Inst.` 12, Birzhevaya line, St Petersburg (Russian Federation); Tanaka, K A

    1998-03-01

    An analytical description of the pondermotive absorption mechanism at a short high intense laser pulse interaction with a strong inhomogeneous plasma is presented. The optimal conditions for the maximum of resonance absorption of laser pulse interaction with non-uniform plasma at normal incidence are founded. (author)

  5. New method for solving inductive electric fields in the non-uniformly conducting ionosphere

    Directory of Open Access Journals (Sweden)

    H. Vanhamäki

    2006-10-01

    Full Text Available We present a new calculation method for solving inductive electric fields in the ionosphere. The time series of the potential part of the ionospheric electric field, together with the Hall and Pedersen conductances serves as the input to this method. The output is the time series of the induced rotational part of the ionospheric electric field. The calculation method works in the time-domain and can be used with non-uniform, time-dependent conductances. In addition, no particular symmetry requirements are imposed on the input potential electric field. The presented method makes use of special non-local vector basis functions called the Cartesian Elementary Current Systems (CECS. This vector basis offers a convenient way of representing curl-free and divergence-free parts of 2-dimensional vector fields and makes it possible to solve the induction problem using simple linear algebra. The new calculation method is validated by comparing it with previously published results for Alfvén wave reflection from a uniformly conducting ionosphere.

  6. New method for solving inductive electric fields in the non-uniformly conducting ionosphere

    Science.gov (United States)

    Vanhamäki, H.; Amm, O.; Viljanen, A.

    2006-10-01

    We present a new calculation method for solving inductive electric fields in the ionosphere. The time series of the potential part of the ionospheric electric field, together with the Hall and Pedersen conductances serves as the input to this method. The output is the time series of the induced rotational part of the ionospheric electric field. The calculation method works in the time-domain and can be used with non-uniform, time-dependent conductances. In addition, no particular symmetry requirements are imposed on the input potential electric field. The presented method makes use of special non-local vector basis functions called the Cartesian Elementary Current Systems (CECS). This vector basis offers a convenient way of representing curl-free and divergence-free parts of 2-dimensional vector fields and makes it possible to solve the induction problem using simple linear algebra. The new calculation method is validated by comparing it with previously published results for Alfvén wave reflection from a uniformly conducting ionosphere.

  7. Development of distributed ion pumps for g-2 beam vacuum system

    Energy Technology Data Exchange (ETDEWEB)

    Hseuh, H.C.; Mapes, M.; Snydstrup, L.

    1993-06-01

    Distributed ion pumps (DIPs) will be used for the beam vacuum system of the g-2 muon storage ring. The magnetic field intensity and alignment angle at the DIP locations are not uniform. The pumping behavior of several different ion pump elements under this non-uniform magnetic field has been studied. The results are compared with the theoretical predictions. Based on these results, the optimum design of the g-2 DIPs has been developed.

  8. Development of distributed ion pumps for g-2 beam vacuum system

    Energy Technology Data Exchange (ETDEWEB)

    Hseuh, H.C.; Mapes, M.; Snydstrup, L.

    1993-01-01

    Distributed ion pumps (DIPs) will be used for the beam vacuum system of the g-2 muon storage ring. The magnetic field intensity and alignment angle at the DIP locations are not uniform. The pumping behavior of several different ion pump elements under this non-uniform magnetic field has been studied. The results are compared with the theoretical predictions. Based on these results, the optimum design of the g-2 DIPs has been developed.

  9. Cloud computing and ROI a new framework for it strategy

    CERN Document Server

    Mohapatra, Sanjay

    2014-01-01

    This book develops an IT strategy for cloud computing that helps businesses evaluate their readiness for cloud services and calculate the ROI. The framework provided helps reduce risks involved in transitioning from traditional "on site" IT strategy to virtual "cloud computing." Since the advent of cloud computing, many organizations have made substantial gains implementing this innovation. Cloud computing allows companies to focus more on their core competencies, as IT enablement is taken care of through cloud services. Cloud Computing and ROI includes case studies covering retail, automobile and food processing industries. Each of these case studies have successfully implemented the cloud computing framework and their strategies are explained. As cloud computing may not be ideal for all businesses, criteria?are also offered to help determine if this strategy should be adopt.

  10. [Study of the influence of uniform transverse magnetic field on the dose distribution of high energy electron beam using Monte Carlo method].

    Science.gov (United States)

    You, Shihu; Xu, Yun; Wu, Zhangwen; Hou, Qing; Guo, Chengjun

    2014-12-01

    In the present work, Monte Carlo simulations were employed to study the characteristics of the dose distribution of high energy electron beam in the presence of uniform transverse magnetic field. The simulations carried out the transport processes of the 30 MeV electron beam in the homogeneous water phantom with different magnetic field. It was found that the dose distribution of the 30 MeV electron beam had changed significantly because of the magnetic field. The result showed that the range of the electron beam was decreased obviously and it formed a very high dose peak at the end of the range, and the ratio of maximum dose to the dose of the surface was greatly increased. The results of this study demonstrated that we could change the depth dose distribution of electron beam which is analogous to the heavy ion by modulating the energy of the electron and magnetic field. It means that using magnetic fields in conjunction with electron radiation therapy has great application prospect, but it also has brought new challenges for the research of dose algorithm.

  11. Radiation flaw detector for testing non-uniform surface bodies of revolution

    International Nuclear Information System (INIS)

    Valevich, M.I.

    1984-01-01

    Radiation flaw detector for testing bodies of revolution with non-uniform surface, welded joints, etc., based on spatial filtration and differentiation of ionizing radiation flux has been described. The calculation of the most important unit of flaw detector - integrators - is made. Experimental studies of the sensitivity have shown, that the radiation flaw detector can be used for rapid testing of products with the sensitivity comparable with the sensitivity of radiographic testing of steel

  12. The effect of aberrated recording beams on reflecting Bragg gratings

    Science.gov (United States)

    SeGall, Marc; Ott, Daniel; Divliansky, Ivan; Glebov, Leonid B.

    2013-03-01

    The effect of aberrations present in the recording beams of a holographic setup is discussed regarding the period and spectral response of a reflecting volume Bragg grating. Imperfect recording beams result in spatially varying resonant wavelengths and the side lobes of the spectrum are washed out. Asymmetrical spectra, spectral broadening, and a reduction in peak diffraction efficiency may also be present, though these effects are less significant for gratings with wider spectral widths. Reflecting Bragg gratings (RBGs) are used as elements in a variety of applications including spectral beam combining1,2, mode locking3,4, longitudinal and transverse mode selection in lasers5,6, and sensing7,8. For applications requiring narrow spectral selectivity9, or large apertures10, these gratings must have a uniform period throughout the length of the recording medium, which may be on the order of millimeters. However, when using typical recording techniques such as two-beam interference for large aperture gratings and phase-mask recording of fiber gratings, aberrations from the optical elements in the system result in an imperfect grating structure11-13. In this paper we consider the effects of aberrations on large aperture gratings recorded in thick media using the two-beam interference technique. Previous works in analyzing the effects of aberrations have considered the effects of aberrations in a single recording plane where the beams perfectly overlap. Such an approach is valid for thin media (on the order of tens of microns), but for thick recording media (on the order of several millimeters) there will be a significant shift in the positions of the beams relative to each other as they traverse the recording medium. Therefore, the fringe pattern produced will not be constant throughout the grating if one or both beams have a non-uniform wavefront. Such non-uniform gratings may have a wider spectral width, a shifted resonant wavelength, or other problems. It is

  13. The importance of non-uniform dose-distribution in an organ

    International Nuclear Information System (INIS)

    Richmond, C.R.

    1975-01-01

    The recent revival of interest in the 'hot particle' problem, especially as regards particulate plutonium and other actinide elements in the lung, stimulated the preparation of this paper. Non-uniformity of dose-distribution has been of concern to standards-setting bodies and other groups such as the National Academy of Sciences and to health protectionists for many years. This paper reviews data from animal experiments that are used by some to implicate particulate plutonium as being especially hazardous to man. Other relevant biological data are also discussed. (author)

  14. SU-F-E-03: PET/CT Guided Dose Boost to Hypoxic Sub-Volume in Nasopharyngeal Carcinomas Using Self-Optimizing Non-Uniform VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, J; Zheng, X; Liu, H; Chen, B; Zhuo, W [FuDan University HuaDong Hospital, Institute of Radiation Medicine Fudan University Shanghai, Shanghai (China)

    2016-06-15

    Purpose: This study is to evaluate the feasibility of simultaneously integrated boost (SIB) to hypoxic subvolume (HTV) in nasopharyngeal carcinomas under the guidance of 18F-Fluoromisonidazole (FMISO) PET/CT using a novel non-uniform volumetric modulated arc therapy (VMAT)technique. Methods: Eight nasopharyngeal carcinoma patients treated with conventional uniform VMAT were retrospectively analyzed. For each treatment, actual conventional uniform VMAT plan with two or more arcs (2–2.5 arcs, totally rotating angle < 1000o) was designed with dose boost to hopxic subvolume (total dose, 84Gy) in the gross tumor volme (GTV) under the guidance of 18F- FMISO PET/CT. Based on the same dataset, experimental single arc non-uniform VAMT plans were generated with the same dose prescription using customized software tools. Dosimetric parameters, quality assurance and the efficiency of the treatment delivery were compared between the uniform and non-uniform VMAT plans. Results: To develop the non-uniform VMAT technique, a specific optimization model was successfully established. Both techniques generate high-quality plans with pass rate (>98%) with the 3mm, 3% criterion. HTV received dose of 84.1±0.75Gy and 84.1±1.2Gy from uniform and non-uniform VMAT plans, respectively. In terms of target coverage and dose homogeneity, there was no significant statistical difference between actual and experimental plans for each case. However, for critical organs at risk (OAR), including the parotids, oral cavity and larynx, dosimetric difference was significant with better dose sparing form experimental plans. Regarding plan implementation efficiency, the average machine time was 3.5 minutes for the actual VMAT plans and 3.7 minutes for the experimental nonuniform VMAT plans (p>0.050). Conclusion: Compared to conventional VMAT technique, the proposed non-uniform VMAT technique has the potential to produce efficient and safe treatment plans, especially in cases with complicated anatomical

  15. Centrifugal pumping during Czochralski silicon growth with a strong, non-uniform, axisymmetric magnetic field

    Science.gov (United States)

    Khine, Y. Y.; Walker, J. S.

    1996-08-01

    Centrifugal pumping flows are produced in the melt by the rotations of crystal and crucible during the Czochralski growth of silicon crystals. This paper treats the centrifugal pumping effects with a steady, strong, non-uniform axisymmetric magnetic field. We consider a family of magnetic fields ranging from a uniform axial field to a "cusp" field, which has a purely radial field at the crystal-melt interface and free surface. We present the numerical solutions for the centrifugal pumping flows as the magnetic field is changed continuously from a uniform axial field to a cusp one, and for arbitrary Hartmann number. Since the perfect alignment between the local magnetic field vector and the crystal-melt interface or free surface is not likely, we also investigate the effects of a slight misalignment.

  16. Effect of non-uniform Hall parameter on the electrode voltage drop in Faraday-type combustion MHD generators

    International Nuclear Information System (INIS)

    Gupta, G.P.; Rohatgi, V.K.

    1982-01-01

    Following a simplified approach, an expression is derived for the gas-dynamic voltage drop in a finitely segmented Faraday-type combustion MHD generator, taking into account the non-uniform Hall parameter across the channel. Combining the electrical sheath voltage drop, discussed briefly, with the gas-dynamic voltage drop, the effect of a non-uniform Hall parameter on the electrode voltage drop is studied using the theoretical and experimental input parameters of the Indian MHD channel test. The condition for the validity of the usual assumption of uniform Hall parameter across the channel is pointed out. Analysis of the measured electrode voltage drop predicts the real gas conductivity in the core to be in the range of 60 to 75 per cent of the theoretically calculated core conductivity. (author)

  17. Spatial model of the gecko foot hair: functional significance of highly specialized non-uniform geometry.

    Science.gov (United States)

    Filippov, Alexander E; Gorb, Stanislav N

    2015-02-06

    One of the important problems appearing in experimental realizations of artificial adhesives inspired by gecko foot hair is so-called clusterization. If an artificially produced structure is flexible enough to allow efficient contact with natural rough surfaces, after a few attachment-detachment cycles, the fibres of the structure tend to adhere one to another and form clusters. Normally, such clusters are much larger than original fibres and, because they are less flexible, form much worse adhesive contacts especially with the rough surfaces. Main problem here is that the forces responsible for the clusterization are the same intermolecular forces which attract fibres to fractal surface of the substrate. However, arrays of real gecko setae are much less susceptible to this problem. One of the possible reasons for this is that ends of the seta have more sophisticated non-uniformly distributed three-dimensional structure than that of existing artificial systems. In this paper, we simulated three-dimensional spatial geometry of non-uniformly distributed branches of nanofibres of the setal tip numerically, studied its attachment-detachment dynamics and discussed its advantages versus uniformly distributed geometry.

  18. On the Super-Turing Computational Power of Non-Uniform Families of Neuromata

    Czech Academy of Sciences Publication Activity Database

    Wiedermann, Jiří

    2002-01-01

    Roč. 12, č. 5 (2002), s. 509-516 ISSN 1210-0552. [SOFSEM 2002 Workshop on Soft Computing. Milovy, 28.11.2002-29.11.2002] R&D Projects: GA ČR GA201/00/1489 Institutional research plan: AV0Z1030915 Keywords : neuromata * Turing machines with advice * non-uniform computational complexity * super-Turing computational power Subject RIV: BA - General Mathematics

  19. Design technique for all-dielectric non-polarizing beam splitter plate

    Science.gov (United States)

    Rizea, A.

    2012-03-01

    There are many situations when, for the proper working, an opto-electronic device requiring optical components does not change the polarization state of light after a reflection, splitting or filtering. In this paper, a design for a non-polarizing beam splitter plate is proposed. Based on certain optical properties of homogeneous dielectric materials we will establish a reliable thin film package formula, excellent for the start of optimization to obtain a 20-nm bandwidth non-polarizing beam splitter.

  20. A design study of non-adiabatic electron guns

    International Nuclear Information System (INIS)

    Barroso, J.J.; Stellati, C.

    1994-01-01

    The design of a non-adiabatic gun capable of producing a 10 A, 50 KeV high-quality laminar electron beam is reported. In contrast to the magnetron injection gun with a conical cathode, where the beam is generated initially with a transverse velocity component, in the non-adiabatic gun electrons are extracted in a direction parallel to the axial guide magnetic field. The beam electrons acquire cyclotron motion as result of non-adiabatic processes in a strong non uniform electric field across the modulation anode. Such an extraction method gives rise to favourable features that are explored throughout the work. An extensive numerical simulation study has also been done to minimize velocity and energy spreads. (author). 3 refs, 5 figs, 1 tab

  1. Output Beam Polarisation of X-ray Lasers with Transient Inversion

    Science.gov (United States)

    Janulewicz, K. A.; Kim, C. M.; Matouš, B.; Stiel, H.; Nishikino, M.; Hasegawa, N.; Kawachi, T.

    It is commonly accepted that X-ray lasers, as the devices based on amplified spontaneous emission (ASE), did not show any specific polarization in the output beam. The theoretical analysis within the uniform (single-mode) approximation suggested that the output radiation should show some defined polarization feature, but randomly changing from shot-to-shot. This hypothesis has been verified by experiment using traditional double-pulse scheme of transient inversion. Membrane beam-splitter was used as a polarization selector. It was found that the output radiation has a significant component of p-polarisation in each shot. To explain the effect and place it in the line with available, but scarce data, propagation and kinetic effects in the non-uniform plasma have been analysed.

  2. The Criticality of Connecting People to Financial Results ‒ an ROI Calculation Model for Romanian FSOs

    Directory of Open Access Journals (Sweden)

    Daniela Niculescu

    2016-02-01

    Full Text Available Organisational culture and employee engagement have been the focus of recent broad-based research efforts. Adding this concern to the revealed importance of performance indicators on human capital, and that their use is getting momentum, in order to attach financial values to knowledge management assets, it becomes more and more critical to measure human capital value. Key for Romanian FSO’s managers becomes to consider that both human and financial values have a focus on adding value in every process and function in the organisation, and to perpetuate organisational profitability by the corporate culture, on the one hand, where culture is a powerful factor that helps a company to engage, on the other hand, talented people. There is a substantial concern on using ROI on Learning and Development programmes, but whilst this is still declared, Romanian FSOs do not yet have a consistent method to measure it. This study is showing the criticality of connecting people to financial results and data analysis suggests that ROI calculation has a positive impact on creating and fostering a powerful organisational culture and that employees’ awareness of ROI values within their organisation has a powerful effect on their sense of engagement. Our findings have a more practical implication for the analysed industry by shaping a formal ROI measurement mechanisms blueprint, an ROI calculation model for the Romanian FSOs, in the form of a mechanism that could be employed when considering the design of an ROI Methodology for Romanian FSOs.

  3. Land-use change and managed aquifer recharge effects on the hydrogeochemistry of two contrasting atoll island aquifers, Roi-Namur Island, Republic of the Marshall Islands

    International Nuclear Information System (INIS)

    Hejazian, Mehrdad; Gurdak, Jason J.; Swarzenski, Peter; Odigie, Kingsley O.; Storlazzi, Curt D.

    2017-01-01

    Freshwater resources on low-lying atoll islands are highly vulnerable to climate change and sea-level rise. In addition to rainwater catchment, groundwater in the freshwater lens is a critically important water resource on many atoll islands, especially during drought. Although many atolls have high annual rainfall rates, dense natural vegetation and high evapotranspiration rates can limit recharge to the freshwater lens. Here we evaluate the effects of land-use/land-cover change and managed aquifer recharge on the hydrogeochemistry and supply of groundwater on Roi-Namur Island, Republic of the Marshall Islands. Roi-Namur is an artificially conjoined island that has similar hydrogeology on the Roi and Namur lobes, but has contrasting land-use/land-cover and managed aquifer recharge only on Roi. Vegetation removal and managed aquifer recharge operations have resulted in an estimated 8.6 × 10"5 m"3 of potable groundwater in the freshwater lens on Roi, compared to only 1.6 × 10"4 m"3 on Namur. We use groundwater samples from a suite of 33 vertically nested monitoring wells, statistical testing, and geochemical modeling using PHREEQC to show that the differences in land-use/land-cover and managed aquifer recharge on Roi and Namur have a statistically significant effect on several groundwater-quality parameters and the controlling geochemical processes. Results also indicate a six-fold reduction in the dissolution of carbonate rock in the freshwater lens and overlying vadose zone of Roi compared to Namur. Mixing of seawater and the freshwater lens is a more dominant hydrogeochemical process on Roi because of the greater recharge and flushing of the aquifer with freshwater as compared to Namur. In contrast, equilibrium processes and dissolution-precipitation non-equilibrium reactions are more dominant on Namur because of the longer residence times relative to the rate of geochemical reactions. Findings from Roi-Namur Island support selective land

  4. Beam-phase monitoring with non-destructive pickup

    International Nuclear Information System (INIS)

    Bogaty, J.; Clifft, B.E.

    1995-01-01

    An intensity and phase-sensitive capacitive pickup was installed at the entrance to the PII linac. This device is based on an extension of the design of the Beam Current Monitor developed as part of the ATLAS radiation safety system. The purpose of the pickup is to allow the arrival phase of the beam from the ECR source at the entrance to the PII linac to be set to a standard which reproduces previous tune conditions and establishes a standard. The new pickups and associated electronics demonstrated sensitivity well below 1 electrical nanoamp but can handle beam currents of many electrical microamps as well. In addition to phase information, beam current is also measured by the units thus providing a continuous, non-intercepting current readout as well. From the very first use of PII, we established a few open-quotes reference tunesclose quotes for the linac and scaled those tunes for any other beam desired. For such scaling to work properly, the velocity and phase of the beam from the ion source must be fixed and reproducible. In last year's FWP the new ATLAS Master Oscillator System was described. The new system has the ability of easily adjusting the beam arrival phase at the entrance to each of the major sections of the facility - PII, Booster, ATLAS. Our present techniques for establishing the beam arrival phase at the entrance of each of the linac sections are cumbersome and, sometimes, intellectually challenging. The installation of these capacitative pickups at the entrance to each of the linac sections will make the determination and setting of the beam arrival phase direct, simple, and dynamic. This should dramatically shorten our setup time for open-quotes old-tuneclose quotes configurations and increase useful operating hours. Permanent electronics for the PII entrance pickup is under construction

  5. Energy Cascade from Internal Modes in Non-uniformly Stratified Fluid through Excitation of Superharmonic Disturbances

    Science.gov (United States)

    Sutherland, B. R.

    2016-02-01

    It is well established that two-dimensional internal plane waves and modes in uniformly stratified fluid efficiently transfer energy to smaller scale waves and ultimately turbulent mixing through parametric subharmonic instability (PSI). The numerical simulations of MacKinnon & Winters (GRL 2005) predicted PSI should act efficiently to disrupt the internal tide. However, while in situ observations showed the presence of PSI, it was not found to be appreciable. One reason for the discrepancy between simulations and observations is that the former examined an internal mode in uniformly stratified fluid whereas, in reality, the internal tide exists in non-uniform stratification and is manifest as sinusoidal oscillations of the thermocline. Through theory supported by numerical simulations, it is shown that internal modes in non-uniform stratification immediately excite superharmonics, not subharmonic disturbances. These have double the horizontal wavenumber and double the frequency of the parent mode and hence move with the same horizontal phase speed of the parent mode. As the disturbances grow in amplitude, however, they interact with the parent mode generating small-scale vertically propagating internal waves within the strongly stratified layer. The occurrence of PSI over very long times can occur, as in the simulations of Hazewinkel and Winters (JPO 2011). However, a comprehensive understanding of the energy cascade from the internal tide to small scales must consider the evolution of excited superharmonic disturbances.

  6. A method to estimate the fractional fat volume within a ROI of a breast biopsy for WAXS applications: Animal tissue evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Robert Y., E-mail: rx-tang@laurentian.ca [Biomolecular Sciences Program, Laurentian University, 935 Ramsey Lake Road, Sudbury, Ontario P3E 2C6 (Canada); McDonald, Nancy, E-mail: mcdnancye@gmail.com; Laamanen, Curtis, E-mail: cx-laamanen@laurentian.ca [Department of Physics, Laurentian University, 935 Ramsey Lake Road, Sudbury, Ontario P3E 2C6 (Canada); LeClair, Robert J., E-mail: rleclair@laurentian.ca [Department of Physics, Laurentian University, 935 Ramsey Lake Road, Sudbury, Ontario P3E 2C6, Canada and Biomolecular Sciences Program, Laurentian University, 935 Ramsey Lake Road, Sudbury, Ontario P3E 2C6 (Canada)

    2014-11-01

    Purpose: To develop a method to estimate the mean fractional volume of fat (ν{sup ¯}{sub fat}) within a region of interest (ROI) of a tissue sample for wide-angle x-ray scatter (WAXS) applications. A scatter signal from the ROI was obtained and use of ν{sup ¯}{sub fat} in a WAXS fat subtraction model provided a way to estimate the differential linear scattering coefficient μ{sub s} of the remaining fatless tissue. Methods: The efficacy of the method was tested using animal tissue from a local butcher shop. Formalin fixed samples, 5 mm in diameter 4 mm thick, were prepared. The two main tissue types were fat and meat (fibrous). Pure as well as composite samples consisting of a mixture of the two tissue types were analyzed. For the latter samples, ν{sub fat} for the tissue columns of interest were extracted from corresponding pixels in CCD digital x-ray images using a calibration curve. The means ν{sup ¯}{sub fat} were then calculated for use in a WAXS fat subtraction model. For the WAXS measurements, the samples were interrogated with a 2.7 mm diameter 50 kV beam and the 6° scattered photons were detected with a CdTe detector subtending a solid angle of 7.75 × 10{sup −5} sr. Using the scatter spectrum, an estimate of the incident spectrum, and a scatter model, μ{sub s} was determined for the tissue in the ROI. For the composite samples, a WAXS fat subtraction model was used to estimate the μ{sub s} of the fibrous tissue in the ROI. This signal was compared to μ{sub s} of fibrous tissue obtained using a pure fibrous sample. Results: For chicken and beef composites, ν{sup ¯}{sub fat}=0.33±0.05 and 0.32 ± 0.05, respectively. The subtractions of these fat components from the WAXS composite signals provided estimates of μ{sub s} for chicken and beef fibrous tissue. The differences between the estimates and μ{sub s} of fibrous obtained with a pure sample were calculated as a function of the momentum transfer x. A t-test showed that the mean of the

  7. Photonic Crystal Polarizing and Non-Polarizing Beam Splitters

    International Nuclear Information System (INIS)

    Chun-Ying, Guan; Jin-Hui, Shi; Li-Boo, Yuan

    2008-01-01

    A polarizing beam splitter (PBS) and a non-polarizing beam splitter (NPBS) based on a photonic crystal (PC) directional coupler are demonstrated. The photonic crystal directional coupler consists of a hexagonal lattice of dielectric pillars in air and has a complete photonic band gap. The photonic band structure and the band gap map are calculated using the plane wave expansion (PWE) method. The splitting properties of the splitter are investigated numerically using the finite difference time domain (FDTD) method

  8. Generation of uniform low-temperature plasma in a pulsed non-self-sustained glow discharge with a large-area hollow cathode

    Energy Technology Data Exchange (ETDEWEB)

    Akhmadeev, Yu. H.; Denisov, V. V., E-mail: volodyadenisov@yandex.ru; Koval, N. N.; Kovalsky, S. S.; Lopatin, I. V.; Schanin, P. M.; Yakovlev, V. V. [Russian Academy of Sciences, Institute of High-Current Electronics, Siberian Branch (Russian Federation)

    2017-01-15

    Generation of plasma in a pulsed non-self-sustained glow discharge with a hollow cathode with an area of ≥2 m{sup 2} at gas pressures of 0.4–1 Pa was studied experimentally. At an auxiliary arc-discharge current of 100 A and a main discharge voltage of 240 V, a pulse-periodic glow discharge with a current amplitude of 370 A, pulse duration of 340 μs, and repetition rate of 1 kHz was obtained. The possibility of creating a uniform gas-discharge plasma with a density of up to 10{sup 12} cm{sup −3} and an electron temperature of 1 eV in a volume of >0.2 m{sup 3} was demonstrated. Such plasma can be efficiently used to treat material surfaces and generate pulsed ion beams with a current density of up to 15 mA/cm{sup 2}.

  9. Spot size characterization of focused non-Gaussian X-ray laser beams.

    Science.gov (United States)

    Chalupský, J; Krzywinski, J; Juha, L; Hájková, V; Cihelka, J; Burian, T; Vysín, L; Gaudin, J; Gleeson, A; Jurek, M; Khorsand, A R; Klinger, D; Wabnitz, H; Sobierajski, R; Störmer, M; Tiedtke, K; Toleikis, S

    2010-12-20

    We present a new technique for the characterization of non-Gaussian laser beams which cannot be described by an analytical formula. As a generalization of the beam spot area we apply and refine the definition of so called effective area (A(eff)) [1] in order to avoid using the full-width at half maximum (FWHM) parameter which is inappropriate for non-Gaussian beams. Furthermore, we demonstrate a practical utilization of our technique for a femtosecond soft X-ray free-electron laser. The ablative imprints in poly(methyl methacrylate) - PMMA and amorphous carbon (a-C) are used to characterize the spatial beam profile and to determine the effective area. Two procedures of the effective area determination are presented in this work. An F-scan method, newly developed in this paper, appears to be a good candidate for the spatial beam diagnostics applicable to lasers of various kinds.

  10. Non-uniform plastic deformation of micron scale objects

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof; Hutchinson, J. W.

    2003-01-01

    Significant increases in apparent flow strength are observed when non-uniform plastic deformation of metals occurs at the scale ranging from roughly one to ten microns. Several basic plane strain problems are analyzed numerically in this paper based on a new formulation of strain gradient...... plasticity. The problems are the tangential and normal loading of a finite rectangular block of material bonded to rigid platens and having traction-free ends, and the normal loading of a half-space by a flat, rigid punch. The solutions illustrate fundamental features of plasticity at the micron scale...... that are not captured by conventional plasticity theory. These include the role of material length parameters in establishing the size dependence of strength and the elevation of resistance to plastic flow resulting from constraint on plastic flow at boundaries. Details of the finite element method employed...

  11. Computerized analysis of mammographic parenchymal patterns for assessing breast cancer risk: Effect of ROI size and location

    International Nuclear Information System (INIS)

    Li Hui; Giger, Maryellen L.; Huo Zhimin; Olopade, Olufunmilayo I.; Lan Li; Weber, Barbara L.; Bonta, Ioana

    2004-01-01

    The long-term goal of our research is to develop computerized radiographic markers for assessing breast density and parenchymal patterns that may be used together with clinical measures for determining the risk of breast cancer and assessing the response to preventive treatment. In our earlier studies, we found that women at high risk tended to have dense breasts with mammographic patterns that were coarse and low in contrast. With our method, computerized texture analysis is performed on a region of interest (ROI) within the mammographic image. In our current study, we investigate the effect of ROI size and ROI location on the computerized texture features obtained from 90 subjects (30 BRCA1/BRCA2 gene-mutation carriers and 60 age-matched women deemed to be at low risk for breast cancer). Mammograms were digitized at 0.1 mm pixel size and various ROI sizes were extracted from different breast regions in the craniocaudal (CC) view. Seventeen features, which characterize the density and texture of the parenchymal patterns, were extracted from the ROIs on these digitized mammograms. Stepwise feature selection and linear discriminant analysis were applied to identify features that differentiate between the low-risk women and the BRCA1/BRCA2 gene-mutation carriers. ROC analysis was used to assess the performance of the features in the task of distinguishing between these two groups. Our results show that there was a statistically significant decrease in the performance of the computerized texture features, as the ROI location was varied from the central region behind the nipple. However, we failed to show a statistically significant decrease in the performance of the computerized texture features with decreasing ROI size for the range studied

  12. Modelling of the reactive sputtering process with non-uniform discharge current density and different temperature conditions

    International Nuclear Information System (INIS)

    Vasina, P; Hytkova, T; Elias, M

    2009-01-01

    The majority of current models of the reactive magnetron sputtering assume a uniform shape of the discharge current density and the same temperature near the target and the substrate. However, in the real experimental set-up, the presence of the magnetic field causes high density plasma to form in front of the cathode in the shape of a toroid. Consequently, the discharge current density is laterally non-uniform. In addition to this, the heating of the background gas by sputtered particles, which is usually referred to as the gas rarefaction, plays an important role. This paper presents an extended model of the reactive magnetron sputtering that assumes the non-uniform discharge current density and which accommodates the gas rarefaction effect. It is devoted mainly to the study of the behaviour of the reactive sputtering rather that to the prediction of the coating properties. Outputs of this model are compared with those that assume uniform discharge current density and uniform temperature profile in the deposition chamber. Particular attention is paid to the modelling of the radial variation of the target composition near transitions from the metallic to the compound mode and vice versa. A study of the target utilization in the metallic and compound mode is performed for two different discharge current density profiles corresponding to typical two pole and multipole magnetics available on the market now. Different shapes of the discharge current density were tested. Finally, hysteresis curves are plotted for various temperature conditions in the reactor.

  13. Spatially-Resolved Ion Trajectory Measurements During Cl2 Reactive Ion Beam Etching and Ar Ion Beam Etching

    International Nuclear Information System (INIS)

    Vawter, G. Allen; Woodworth, Joseph R.; Zubrzycki, Walter J.

    1999-01-01

    The angle of ion incidence at the etched wafer location during RIBE and IBE using Cl 2 , Ar and O 2 ion beams has been characterized using an ion energy and angle analyzer. Effects of beam current and accelerator grid bias on beam divergence and the spatial uniformity of the spread of incident angles are measured. It is observed that increased total beam current can lead to reduced current density at the sample stage due to enhanced beam divergence at high currents. Results are related to preferred etch system design for uniform high-aspect-ratio etching across semiconductor wafers

  14. Effect of non-uniform mean flow field on acoustic propagation problems in computational aeroacoustics

    DEFF Research Database (Denmark)

    Si, Haiqing; Shen, Wen Zhong; Zhu, Wei Jun

    2013-01-01

    Acoustic propagation in the presence of a non-uniform mean flow is studied numerically by using two different acoustic propagating models, which solve linearized Euler equations (LEE) and acoustic perturbation equations (APE). As noise induced by turbulent flows often propagates from near field t...

  15. Laser beam shaping design based on micromirror array

    Science.gov (United States)

    Fang, Han; Su, Bida; Liu, Jiaguo; Fan, Xiaoli; Jing, Wang

    2017-10-01

    In the practical application of the laser, it is necessary to use the laser beam shaping technology to shape the output beam of laser device to the uniform light intensity distribution. The shaping divergent optical system of compound eye integrator way is composed of beam expanding mirror group and lens array. Its working principle is to expand the output laser to a certain size of caliber, and then divide the beam with lens array into multiple sub beam, where the lens unit of lens array can control the divergence angle of sub beam through the design of focal length, with mutual superposition of the sub beam in far field, to make up for the nonuniformity of beam, so that the radiant exitance on the radiated surface may become uniform. In this paper, we use a reflective microlens array to realize the laser beam shaping. By through of the practical optical path model established, the ray tracing is carried out and the simulation results for single-mode Gaussian beam with noise circumstance is provided. The analysis results show that the laser beam shaping under different inputs can be effectively realized by use of microlens array. All the energy is within the signal window, with a high energy efficiency of more than 90%; The measured surface has a better uniformity, and the uniformity is better than 99.5% at 150m.

  16. Entrance and Exit CSR Impedance for Non-Ultrarelativistic Beam

    Energy Technology Data Exchange (ETDEWEB)

    Li, Rui; Tsai, Cheng Ying [SLAC National Accelerator Lab., Menlo Park, CA (United States); Virginia Polytechnic Inst. and State Univ. (Virginia Tech), Blacksburg, VA (United States)

    2017-05-01

    For a high-brightness electron beam being transported through beamlines involving bending systems, the coherent synchrotron radiation (CSR) and longitudinal space charge (LSC) interaction could often cause microbunching instability. The semi-analytical Vlasov solver for microbunching gain* depends on the impedances for the relevant collective effects. The existing results for CSR impedances are usually obtained for the ultrarelativistic limit. To extend the microbunching analysis to cases of low energies, such as the case of an ERL merger, or to density modulations at extremely small wavelength, it is necessary to extend the impedance analysis to the non-ultrarelativistic regime. In this study, we present the impedance analysis for the transient CSR interaction in the non-ultrarelativistic regime, for transients including both entrance to and exit from a magnetic dipole. These impedance results will be compared to their ultra-relativistic counterparts**, and the corresponding wakefield obtained from the impedance for low-energy beams will be compared with the existing results of transient CSR wakefield for general beam energies***.

  17. Beam Induced Pressure Rise at RHIC

    CERN Document Server

    Zhang, S Y; Bai, Mei; Blaskiewicz, Michael; Cameron, Peter; Drees, Angelika; Fischer, Wolfram; Gullotta, Justin; He, Ping; Hseuh Hsiao Chaun; Huang, Haixin; Iriso, Ubaldo; Lee, Roger C; Litvinenko, Vladimir N; MacKay, William W; Nicoletti, Tony; Oerter, Brian; Peggs, Steve; Pilat, Fulvia Caterina; Ptitsyn, Vadim; Roser, Thomas; Satogata, Todd; Smart, Loralie; Snydstrup, Louis; Thieberger, Peter; Trbojevic, Dejan; Wang, Lanfa; Wei, Jie; Zeno, Keith

    2005-01-01

    Beam induced pressure rise in RHIC warm sections is currently one of the machine intensity and luminosity limits. This pressure rise is mainly due to electron cloud effects. The RHIC warm section electron cloud is associated with longer bunch spacings compared with other machines, and is distributed non-uniformly around the ring. In addition to the countermeasures for normal electron cloud, such as the NEG coated pipe, solenoids, beam scrubbing, bunch gaps, and larger bunch spacing, other studies and beam tests toward the understanding and counteracting RHIC warm electron cloud are of interest. These include the ion desorption studies and the test of anti-grazing ridges. For high bunch intensities and the shortest bunch spacings, pressure rises at certain locations in the cryogenic region have been observed during the past two runs. Beam studies are planned for the current 2005 run and the results will be reported.

  18. Sequential, progressive, equal-power, reflective beam-splitter arrays

    Science.gov (United States)

    Manhart, Paul K.

    2017-11-01

    The equations to calculate equal-power reflectivity of a sequential series of beam splitters is presented. Non-sequential optical design examples are offered for uniform illumination using diode lasers. Objects created using Boolean operators and Swept Surfaces can create objects capable of reflecting light into predefined elevation and azimuth angles. Analysis of the illumination patterns for the array are also presented.

  19. Buoyant convection during Czochralski silicon growth with a strong, non-uniform, axisymmetric magnetic field

    Science.gov (United States)

    Khine, Y. Y.; Walker, J. S.

    1995-02-01

    This paper treats the buoyant convection during the Czochralski growth of silicon crystals with a steady, strong, non-uniform, axisymmetric magnetic field. We consider a family of magnetic fields which includes a uniform axial magnetic field and a "cusp" field which is produced by identical solenoids placed symmetrically above and below the plane of the crystal-melt interface and free surface. We investigate the evolution of the buoyant convection as the magnetic field is changed continuously from a uniform axial field to a cusp field, with a constant value of the root-mean-squared magnetic flux density in the melt. We also investigate changes as the magnetic flux density is increased. While the cusp field appears very promising, perfect alignment between the local magnetic field vector and the crystal-melt interface or free surface is not possible, so the effects of a slight misalignment are also investigated.

  20. Reconstruction for interior region-of-interest inverse geometry computed tomography: preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Su; Kim, Tae Ho; Kim, Kyeong Hyeon; Yoon, Do Kun; Suh, Tae Suk [Dept. of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Kang, Seong Hee [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of); Cho, Min Seok [Dept. of Radiation Oncology, Asan Medical Center, Seoul (Korea, Republic of); Noh, Yu Yoon [Dept. of Radiation Oncology, Eulji University Hospital, Daejeon (Korea, Republic of)

    2017-04-15

    The inverse geometry computed tomography (IGCT) composed of multiple source and small size detector has several merits such as reduction of scatter effect and large volumetric imaging within one rotation without cone-beam artifact, compared to conventional cone-beam computed tomography (CBCT). By using this multi-source characteristics, we intend to present a selective and multiple interior region-of-interest (ROI) imaging method by using a designed source on-off sequence of IGCT. ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. In this regard, it seems to be useful for diagnostic or image guidance for radiotherapy. ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. Projection of ROI-IGCT is performed by selective irradiation, hence unnecessary imaging dose to non-interest region can be reduced. In this regard, it seems to be useful for diagnostic or image guidance for radiotherapy.

  1. Hydrodynamic characteristics of steady magnetic fluid flow in a straight tube by taking into account the non-uniform distribution of mass concentration

    International Nuclear Information System (INIS)

    Shuchi, S.; Shimada, K.; Kamiyama, S.; Yamaguchi, H.

    2002-01-01

    We clarify numerically the wall friction coefficient, the distributions of velocity and shear rate, and the number of aggregated particles on steady magnetic fluid flow in a straight tube by taking into account the non-uniform distribution of mass concentration (DMC). Also the effect of DMC is clarified under the uniform and non-uniform transverse steady magnetic field. In comparison with the published data, the numerical results show good agreement with the experimental data

  2. The segmented non-uniform dielectric module design for uniformity control of plasma profile in a capacitively coupled plasma chamber

    International Nuclear Information System (INIS)

    Xia, Huanxiong; Xiang, Dong; Yang, Wang; Mou, Peng

    2014-01-01

    Low-temperature plasma technique is one of the critical techniques in IC manufacturing process, such as etching and thin-film deposition, and the uniformity greatly impacts the process quality, so the design for the plasma uniformity control is very important but difficult. It is hard to finely and flexibly regulate the spatial distribution of the plasma in the chamber via controlling the discharge parameters or modifying the structure in zero-dimensional space, and it just can adjust the overall level of the process factors. In the view of this problem, a segmented non-uniform dielectric module design solution is proposed for the regulation of the plasma profile in a CCP chamber. The solution achieves refined and flexible regulation of the plasma profile in the radial direction via configuring the relative permittivity and the width of each segment. In order to solve this design problem, a novel simulation-based auto-design approach is proposed, which can automatically design the positional sequence with multi independent variables to make the output target profile in the parameterized simulation model approximate the one that users preset. This approach employs an idea of quasi-closed-loop control system, and works in an iterative mode. It starts from initial values of the design variable sequences, and predicts better sequences via the feedback of the profile error between the output target profile and the expected one. It never stops until the profile error is narrowed in the preset tolerance

  3. Physical correction model for automatic correction of intensity non-uniformity in magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Stefan Leger

    2017-10-01

    Conclusion: The proposed PCM algorithm led to a significantly improved image quality compared to the originally acquired images, suggesting that it is applicable to the correction of MRI data. Thus it may help to reduce intensity non-uniformity which is an important step for advanced image analysis.

  4. Uniform current density and divergence control in high power extraction ion diodes

    International Nuclear Information System (INIS)

    Desjarlais, M.P.; Coats, R.S.; Lockner, T.R.; Pointon, T.D.; Johnson, D.J.; Slutz, S.A.; Lemke, R.W.; Cuneo, M.E.; Mehlhorn, T.A.

    1996-01-01

    A theory of radial beam uniformity in extraction ion diodes is presented. The theory is based on a locally one-dimensional analysis of the diamagnetic compression of magnetic streamlines and the self-consistent determination of the virtual cathode location. The radial dependence of the applied magnetic field is used to determine the critical parameters of this locally one-dimensional treatment. The theory has been incorporated into the ATHETA magnetic field code to allow the rapid evaluation of realistic magnetic field configurations. Comparisons between the theoretical results, simulations with the QUICKSILVER code, and experiments on the PBFA-X accelerator establish the usefulness of this tool for tuning magnetic fields to improve ion beam uniformity. The consequences of poor beam uniformity on the evolution of ion diode instabilities are discussed with supporting evidence from simulations, theory, and experiments. (author). 8 figs., 15 refs

  5. Uniform current density and divergence control in high power extraction ion diodes

    International Nuclear Information System (INIS)

    Desjarlais, M.P.; Coats, R.S.; Lockner, T.R.; Pointon, T.D.; Johnson, D.J.; Slutz, S.A.; Lemke, R.W.; Cuneo, M.E.; Melhorn, T.A.

    1996-01-01

    A theory of radial beam uniformity in extraction ion diodes is presented. The theory is based on a locally one dimensional analysis of the diamagnetic compression of magnetic streamlines and the self consistent determination of the virtual cathode location. The radial dependence of the applied magnetic field is used to determine the critical parameters of this locally one dimensional treatment. The theory has been incorporated into the ATHETA magnetic field code to allow the rapid evaluation of realistic magnetic field configurations. Comparisons between the theoretical results, simulations with the QUICKSILVER code, and experiments on the PBFA-X accelerator establish the usefulness of this tool for tuning magnetic fields to improve ion beam uniformity. The consequences of poor beam uniformity on the evolution of ion diode instabilities are discussed with supporting evidence from simulations, theory, and experiments

  6. Uniform current density and divergence control in high power extraction ion diodes

    Energy Technology Data Exchange (ETDEWEB)

    Desjarlais, M P; Coats, R S; Lockner, T R; Pointon, T D; Johnson, D J; Slutz, S A; Lemke, R W; Cuneo, M E; Mehlhorn, T A [Sandia Labs., Albuquerque, NM (United States)

    1997-12-31

    A theory of radial beam uniformity in extraction ion diodes is presented. The theory is based on a locally one-dimensional analysis of the diamagnetic compression of magnetic streamlines and the self-consistent determination of the virtual cathode location. The radial dependence of the applied magnetic field is used to determine the critical parameters of this locally one-dimensional treatment. The theory has been incorporated into the ATHETA magnetic field code to allow the rapid evaluation of realistic magnetic field configurations. Comparisons between the theoretical results, simulations with the QUICKSILVER code, and experiments on the PBFA-X accelerator establish the usefulness of this tool for tuning magnetic fields to improve ion beam uniformity. The consequences of poor beam uniformity on the evolution of ion diode instabilities are discussed with supporting evidence from simulations, theory, and experiments. (author). 8 figs., 15 refs.

  7. Uniform elemental analysis of materials by sputtering and photoionization mass spectrometry

    International Nuclear Information System (INIS)

    Chun, He; Basler, J.N.; Becker, C.H.

    1997-01-01

    Analysis of the elemental composition of surfaces commonly involves techniques in which atoms or ions are ablated from the material's surface and detected by mass spectrometry. Secondary-ion mass spectrometry is widely used for detection with high sensitivity (down to a few parts per billion) but technical problems prevent it from being truly quantitative. Some of these problems are circumvented by nonresonant laser post-ionization of sputtered atoms followed by time-of-flight mass spectrometry (surface analysis by laser ionization: SALI). But when there are large differences in ionization probabilities amongst different elements in the material, the detection sensitivity can be non-uniform and accurate quantification remains out of reach. Here we report that highly uniform, quantitative and sensitive analysis of materials can be achieved using a high-energy (5-keV) ion beam for sputtering coupled with a very-high-intensity laser to induce multiphoton ionization of the sputtered atoms. We show uniform elemental sensitivity for several samples containing elements with very different ionization potentials, suggesting that this approach can now be regarded as quantitative for essentially any material. (author)

  8. Non-perturbative measurement of low-intensity charged particle beams

    Science.gov (United States)

    Fernandes, M.; Geithner, R.; Golm, J.; Neubert, R.; Schwickert, M.; Stöhlker, T.; Tan, J.; Welsch, C. P.

    2017-01-01

    Non-perturbative measurements of low-intensity charged particle beams are particularly challenging to beam diagnostics due to the low amplitude of the induced electromagnetic fields. In the low-energy antiproton decelerator (AD) and the future extra low energy antiproton rings at CERN, an absolute measurement of the beam intensity is essential to monitor the operation efficiency. Superconducting quantum interference device (SQUID) based cryogenic current comparators (CCC) have been used for measuring slow charged beams in the nA range, showing a very good current resolution. But these were unable to measure fast bunched beams, due to the slew-rate limitation of SQUID devices and presented a strong susceptibility to external perturbations. Here, we present a CCC system developed for the AD machine, which was optimised in terms of its current resolution, system stability, ability to cope with short bunched beams, and immunity to mechanical vibrations. This paper presents the monitor design and the first results from measurements with a low energy antiproton beam obtained in the AD in 2015. These are the first CCC beam current measurements ever performed in a synchrotron machine with both coasting and short bunched beams. It is shown that the system is able to stably measure the AD beam throughout the entire cycle, with a current resolution of 30 {nA}.

  9. Decomposed Photo Response Non-Uniformity for Digital Forensic Analysis

    Science.gov (United States)

    Li, Yue; Li, Chang-Tsun

    The last few years have seen the applications of Photo Response Non-Uniformity noise (PRNU) - a unique stochastic fingerprint of image sensors, to various types of digital forensic investigations such as source device identification and integrity verification. In this work we proposed a new way of extracting PRNU noise pattern, called Decomposed PRNU (DPRNU), by exploiting the difference between the physical andartificial color components of the photos taken by digital cameras that use a Color Filter Array for interpolating artificial components from physical ones. Experimental results presented in this work have shown the superiority of the proposed DPRNU to the commonly used version. We also proposed a new performance metrics, Corrected Positive Rate (CPR) to evaluate the performance of the common PRNU and the proposed DPRNU.

  10. Charge neutralization of small ion beam clumps

    Energy Technology Data Exchange (ETDEWEB)

    Welch, D R [Mission Research Corp., Albuquerque, NM (United States); Olson, C L; Hanson, D L [Sandia National Labs., Albuquerque, NM (United States)

    1997-12-31

    The mega-ampere currents associated with light ion fusion (LIF) require excellent charge neutralization to prevent divergence growth. As the size and space-charge potential of a beam clump or `beamlet` become small (submillimeter size and kilovolt potentials), the neutralization becomes increasingly difficult. Linear theory predicts that plasma electrons cannot neutralize potentials < {phi}{sub crit} = (1/2)m{sub e}v{sub i}{sup 2}/e, where m{sub e} is the electron mass and v{sub i} is the ion beam velocity. A non-uniform beam would, therefore, have regions with potentials sufficient to add divergence to beam clumps. The neutralization of small beamlets produced on the SABLE accelerator and in numerical simulation has supported the theory, showing a plateau in divergence growths as the potential in the beamlet exceeds {phi}{sub crit}. (author). 1 tab., 2 figs., 4 refs.

  11. A progressively reduced pretension method to fabricate Bradbury-Nielsen gates with uniform tension

    International Nuclear Information System (INIS)

    Ni, Kai; Guo, Jingran; Yu, Zhou; Cao, Like; Yu, Quan; Qian, Xiang; Wang, Xiaohao

    2015-01-01

    A Bradbury-Nielsen gate (BNG) is often used to modulate ion beams. It consists of two interleaved and electrically isolated sets of wires with uniform tension, which ideally keep parallel, equidistant, and coplanar over a wide temperature range, making the BNG reliable and robust. We have previously analyzed the non-uniformity problem of wire tensions with sequentially winding method and developed a template-based transfer method to solve this problem. In this paper, we introduced a progressively reduced pretension method, which allows directly and sequentially fixing wires onto the substrate without using a template. Theoretical analysis shows that by applying proper pretension to each wire when fixing it, the final wire tensions of all wires can be uniform. The algorithm and flowchart to calculate the pretension sequence are given, and the fabrication process is introduced in detail. Pretensions are generated by weight combination with a weaving device. A BNG with stainless steel wire and a printed circuit board substrate is constructed with this method. The non-uniformity of the final wire tensions is less than 2.5% in theory. The BNG is successfully employed in our ion mobility spectrometer, and the measured resolution is 33.5 at a gate opening time of 350 μs. Compared to the template-based method, this method is simpler, faster, and more flexible with comparable production quality when manufacturing BNGs with different configurations

  12. Finite-amplitude, pulsed, ultrasonic beams

    Science.gov (United States)

    Coulouvrat, François; Frøysa, Kjell-Eivind

    An analytical, approximate solution of the inviscid KZK equation for a nonlinear pulsed sound beam radiated by an acoustic source with a Gaussian velocity distribution, is obtained by means of the renormalization method. This method involves two steps. First, the transient, weakly nonlinear field is computed. However, because of cumulative nonlinear effects, that expansion is non-uniform and breaks down at some distance away from the source. So, in order to extend its validity, it is re-written in a new frame of co-ordinates, better suited to following the nonlinear distorsion of the wave profile. Basically, the nonlinear coordinate transform introduces additional terms in the expansion, which are chosen so as to counterbalance the non-uniform ones. Special care is devoted to the treatment of shock waves. Finally, comparisons with the results of a finite-difference scheme turn out favorable, and show the efficiency of the method for a rather large range of parameters.

  13. Diffusion-weighted magnetic resonance imaging in the characterization of testicular germ cell neoplasms: Effect of ROI methods on apparent diffusion coefficient values and interobserver variability

    Energy Technology Data Exchange (ETDEWEB)

    Tsili, Athina C., E-mail: a_tsili@yahoo.gr [Department of Clinical Radiology, Medical School, University of Ioannina, University Campus, 45110, Ioannina (Greece); Ntorkou, Alexandra, E-mail: alexdorkou@hotmail.com [Department of Clinical Radiology, Medical School, University of Ioannina, University Campus, 45110, Ioannina (Greece); Astrakas, Loukas, E-mail: astrakas@uoi.gr [Department of Medical Physics, Medical School, University of Ioannina, University Campus, 45110, Ioannina (Greece); Xydis, Vasilis, E-mail: vxydis@cc.uoi.gr [Department of Clinical Radiology, Medical School, University of Ioannina, University Campus, 45110, Ioannina (Greece); Tsampalas, Stavros, E-mail: stamp@gmail.com [Department of Urology, Medical School, University of Ioannina, University Campus, 45110, Ioannina (Greece); Sofikitis, Nikolaos, E-mail: akrosnin@hotmail.com [Department of Urology, Medical School, University of Ioannina, University Campus, 45110, Ioannina (Greece); Argyropoulou, Maria I., E-mail: margyrop@cc.uoi.gr [Department of Clinical Radiology, Medical School, University of Ioannina, University Campus, 45110, Ioannina (Greece)

    2017-04-15

    Highlights: • Seminomas have lower mean ADC compared to NSGCNs. • Round ROI is accurate in characterizing TGCNS. • ROI shape has no significant effect on interobserver variability. - Abstract: Introduction: To evaluate the difference in apparent diffusion coefficient (ADC) measurements at diffusion-weighted (DW) magnetic resonance imaging of differently shaped regions-of-interest (ROIs) in testicular germ cell neoplasms (TGCNS), the diagnostic ability of differently shaped ROIs in differentiating seminomas from nonseminomatous germ cell neoplasms (NSGCNs) and the interobserver variability. Materials and methods: Thirty-three TGCNs were retrospectively evaluated. Patients underwent MR examinations, including DWI on a 1.5-T MR system. Two observers measured mean tumor ADCs using four distinct ROI methods: round, square, freehand and multiple small, round ROIs. The interclass correlation coefficient was analyzed to assess interobserver variability. Statistical analysis was used to compare mean ADC measurements among observers, methods and histologic types. Results: All ROI methods showed excellent interobserver agreement, with excellent correlation (P < 0.001). Multiple, small ROIs provided the lower mean ADC in TGCNs. Seminomas had lower mean ADC compared to NSGCNs for each ROI method (P < 0.001). Round ROI proved the most accurate method in characterizing TGCNS. Conclusion: Interobserver variability in ADC measurement is excellent, irrespective of the ROI shape. Multiple, small round ROIs and round ROI proved the more accurate methods for ADC measurement in the characterization of TGCNs and in the differentiation between seminomas and NSGCNs, respectively.

  14. A Non-Equilibrium Sediment Transport Model for Dam Break Flow over Moveable Bed Based on Non-Uniform Rectangular Mesh

    Directory of Open Access Journals (Sweden)

    Gangfeng Wu

    2018-05-01

    Full Text Available The use of multiple-level non-uniform rectangular mesh in coupled flow and sediment transport modeling is preferred to achieve high accuracy in important region without increasing computational cost greatly. Here, a robust coupled hydrodynamic and non-equilibrium sediment transport model is developed on non-uniform rectangular mesh to simulate dam break flow over movable beds. The enhanced shallow water and sediment transport equations are adopted to consider the mass and momentum exchange between the flow phase and sediment phase. The flux at the interface is calculated by the positivity preserving central upwind scheme, which belongs to Godunov-type Riemann-problem-solver-free central schemes and is less expensive than other popular Riemann solvers while still capable of tracking wet/dry fronts accurately. The nonnegative water depth reconstruction method is used to achieve second-order accuracy in space. The model was first verified against two laboratory experiments of dam break flow over irregular fixed bed. Then the quantitative performance of the model was further investigated by comparing the computational results with measurement data of dam break flow over movable bed. The good agreements between the measurements and the numerical simulations are found for the flow depth, velocity and bed changes.

  15. One-step fabrication of nanostructure-covered microstructures using selective aluminum anodization based on non-uniform electric field

    Science.gov (United States)

    Park, Yong Min; Kim, Byeong Hee; Seo, Young Ho

    2016-06-01

    This paper presents a selective aluminum anodization technique for the fabrication of microstructures covered by nanoscale dome structures. It is possible to fabricate bulging microstructures, utilizing the different growth rates of anodic aluminum oxide in non-uniform electric fields, because the growth rate of anodic aluminum oxide depends on the intensity of electric field, or current density. After anodizing under a non-uniform electric field, bulging microstructures covered by nanostructures were fabricated by removing the residual aluminum layer. The non-uniform electric field induced by insulative micropatterns was estimated by computational simulations and verified experimentally. Utilizing computational simulations, the intensity profile of the electric field was calculated according to the ratio of height and width of the insulative micropatterns. To compare computational simulation results and experimental results, insulative micropatterns were fabricated using SU-8 photoresist. The results verified that the shape of the bottom topology of anodic alumina was strongly dependent on the intensity profile of the applied electric field, or current density. The one-step fabrication of nanostructure-covered microstructures can be applied to various fields, such as nano-biochip and nano-optics, owing to its simplicity and cost effectiveness.

  16. Current drive by neutral beams, rotating magnetic fields and helicity injection in compact toroids

    International Nuclear Information System (INIS)

    Farengo, R.

    2002-01-01

    A Monte-Carlo code is used to study neutral beam current drive in Spheromaks. The exact particle trajectories are followed in the self-consistent equilibria calculated including the beam current. Reducing Z(eff) does not increase the current drive efficiency because the reduction of the stopping cross section is compensated by an increase in the electron canceling current. Significant changes in the safety factor profile can be produced with relatively low beam currents. Minimum dissipation states of a flux core spheromak sustained by helicity injection are presented. Helicity balance is used as a constraint and the resistivity is considered to be non-uniform. Two types of relaxed states are found; one has a central core of open flux surrounded by a toroidal region of closed flux surfaces and the other has the open flux wrapped around the closed flux surfaces. Non-uniform resistivity effects can be very important due to the changes they produce in the safety factor profile. A hybrid, fluid electrons particle ions, code is employed to study ion dynamics in FRCs sustained by rotating magnetic fields. (author)

  17. Heat transfer in boundary layer stagnation-point flow towards a shrinking sheet with non-uniform heat flux

    International Nuclear Information System (INIS)

    Bhattacharyya Krishnendu

    2013-01-01

    In this paper, the effect of non-uniform heat flux on heat transfer in boundary layer stagnation-point flow over a shrinking sheet is studied. The variable boundary heat fluxes are considered of two types: direct power-law variation with the distance along the sheet and inverse power-law variation with the distance. The governing partial differential equations (PDEs) are transformed into non linear self-similar ordinary differential equations (ODEs) by similarity transformations, and then those are solved using very efficient shooting method. The direct variation and inverse variation of heat flux along the sheet have completely different effects on the temperature distribution. Moreover, the heat transfer characteristics in the presence of non-uniform heat flux for several values of physical parameters are also found to be interesting

  18. Fraction-variant beam orientation optimization for non-coplanar IMRT

    Science.gov (United States)

    O'Connor, Daniel; Yu, Victoria; Nguyen, Dan; Ruan, Dan; Sheng, Ke

    2018-02-01

    Conventional beam orientation optimization (BOO) algorithms for IMRT assume that the same set of beam angles is used for all treatment fractions. In this paper we present a BOO formulation based on group sparsity that simultaneously optimizes non-coplanar beam angles for all fractions, yielding a fraction-variant (FV) treatment plan. Beam angles are selected by solving a multi-fraction fluence map optimization problem involving 500-700 candidate beams per fraction, with an additional group sparsity term that encourages most candidate beams to be inactive. The optimization problem is solved using the fast iterative shrinkage-thresholding algorithm. Our FV BOO algorithm is used to create five-fraction treatment plans for digital phantom, prostate, and lung cases as well as a 30-fraction plan for a head and neck case. A homogeneous PTV dose coverage is maintained in all fractions. The treatment plans are compared with fraction-invariant plans that use a fixed set of beam angles for all fractions. The FV plans reduced OAR mean dose and D 2 values on average by 3.3% and 3.8% of the prescription dose, respectively. Notably, mean OAR dose was reduced by 14.3% of prescription dose (rectum), 11.6% (penile bulb), 10.7% (seminal vesicle), 5.5% (right femur), 3.5% (bladder), 4.0% (normal left lung), 15.5% (cochleas), and 5.2% (chiasm). D 2 was reduced by 14.9% of prescription dose (right femur), 8.2% (penile bulb), 12.7% (proximal bronchus), 4.1% (normal left lung), 15.2% (cochleas), 10.1% (orbits), 9.1% (chiasm), 8.7% (brainstem), and 7.1% (parotids). Meanwhile, PTV homogeneity defined as D 95/D 5 improved from .92 to .95 (digital phantom), from .95 to .98 (prostate case), and from .94 to .97 (lung case), and remained constant for the head and neck case. Moreover, the FV plans are dosimetrically similar to conventional plans that use twice as many beams per fraction. Thus, FV BOO offers the potential to reduce delivery time for non-coplanar IMRT.

  19. Concentration polarization effects on the macromolecular transport in the presence of non-uniform magnetic field: A numerical study using a lumen-wall model

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadpourfard, M., E-mail: Mohammadpour@azaruniv.edu [Department of Mechanical Engineering, Azarbaijan Shahid Madani University, Tabriz 53751-71379 (Iran, Islamic Republic of); Aminfar, H., E-mail: hh_aminfar@tabrizu.ac.ir [Faculty of Mechanical Engineering, University of Tabriz, Tabriz (Iran, Islamic Republic of); Khajeh, K., E-mail: khajeh.k.2005@gmail.com [Faculty of Mechanical Engineering, University of Tabriz, Tabriz (Iran, Islamic Republic of)

    2014-04-01

    In this paper, the concentration polarization phenomena in a two dimensional tube under steady state conditions containing ferrofluid (blood and 4 vol% Fe{sub 3}O{sub 4}) is reported in the presence of non-uniform magnetic field. Lumen-wall model has been used for solving the mass transport equation. Hemodynamics parameters such as flow rate, viscosity, wall shear stress (WSS) and the macromolecules surface concentration which accumulate on the blood vessel wall, influenced the formation and progression of atherosclerosis disease. Effective parameters on the low density lipoprotein (LDL) surface concentration (LSC) such as: the wall filtration velocity, inlet Reynolds number and WSS under applied non-uniform magnetic field have been examined. Numerical solution of governing equations of the flow field have been obtained by using the single-phase model and the control volume technique. Magnetic field is generated by an electric current going through a thin and straight wire oriented perpendicular to the tube. Results show WSS in the vicinity of magnetic field source increased and LSC decreased along the wall. - Highlights: • In this paper the concentration polarization phenomena of blood flow is reported in the presence of non-uniform magnetic field. • In presence of non-uniform magnetic field LSC will decrease along the wall due to the increasing the velocity gradients near the magnetic source. • When non-uniform magnetic field intensity increases, LSC along the wall becomes lower. • Non-uniform magnetic field can affects the flow more in low Reynolds numbers.

  20. Some properties of a non-static uniform density sphere with center singularity

    International Nuclear Information System (INIS)

    Knutsen, H.

    1984-01-01

    A class of exact models for non-static uniform density spheres with pressure gradient and singularity is investigated. Necessary and sufficient conditions are given for the pressure gradient to be negative and for the circumference of the sphere to be an increasing function of radial coordinate. The time history of marginally trapped surfaces are studied, and it is found that for physically acceptable models the singularity is always hidden by a trapped surface. (Auth.)

  1. Diagnose of large area electron beam with faraday cup

    International Nuclear Information System (INIS)

    Tang Ying; Qian Hang; Yi Aiping; Huang Xin; Yu Li; Liu Jingru; Su Jiancang; Ding Zhenjie; Ding Yongzhong; Yu Jianguo

    2008-01-01

    In the experiment of gas laser pumped by electron beam, large area uniform electron beam is important to generate high efficiency laser output. This paper introduces Faraday cup is used in the diagnose experiment on the uniformity of large area e-beam generated by SPG-200 pulsed power generator. Construction of Faraday cup and the results of calibration are presented in detail. The uniformity of velvet emission is given, and the results of experiment are analyzed. (authors)

  2. A new correlation of non-uniformly heated round tube burnout data

    International Nuclear Information System (INIS)

    Kirby, G.J.

    1966-07-01

    A new correlation of non-uniformly heated round tube burnout data is presented. This fits the available data better than any previously published correlation - the root-mean-square deviation being 5.7% for all data at 1000 p.s.i.a. and the worst fit being to data at 2000 p.s.i.a. where the r.m.s. error is 6.6%. The correlation is used to investigate the effect of flux profile changes and no significant increase in burnout power is obtained by modifying the present chopped cosine distribution. (author)

  3. Doppler-shift spectra of Hα lines from negative-ion-based neutral beams for large helical device neutral beam injection

    International Nuclear Information System (INIS)

    Oka, Y.; Ikeda, K.; Takeiri, Y.; Tsumori, K.; Kaneko, O.; Nagaoka, K.; Osakabe, M.; Asano, E.; Kondo, T.; Sato, M.; Shibuya, M.; Grisham, L.; Umeda, N.; Honda, A.; Ikeda, Y.; Yamamoto, T.

    2006-01-01

    The velocity spectra of the negative-ion-(H - ) based neutral beams are studied in high-performance large-area ion sources during injection into large helical device fusion plasmas. We are conducting systematic observations in standard neutral beam injection to correlate beam spectra with source operating conditions. Almost all of the transmitted beam power was at full acceleration energy (∼170 keV). The small stripping beam component which was produced in the extraction gap was evaluated to be about 9%-22% by amplitude of the measured spectra for the sources in beam lines 1 and 2. H - production uniformity from the spectrum profile was 86%-90% for three sources. For the longest pulse injection during 74 and 128 s, a full energy component tended to decrease with time, while the accelerator gap stripping tail tended to increase slightly with time, which is attributed to beam-induced outgassing in the accelerator. A higher conductance multislot ground grid accelerator appeared to show little growth in the accelerator gap beam stripping during long pulses compared to the conventional multiaperture ground grid. The beam uniformity appeared to vary in part with the Cs uniformity on the plasma grid

  4. Uniformity of cylindrical imploding underwater shockwaves at very small radii

    Science.gov (United States)

    Yanuka, D.; Rososhek, A.; Bland, S. N.; Krasik, Ya. E.

    2017-11-01

    We compare the convergent shockwaves generated from underwater, cylindrical arrays of copper wire exploded by multiple kilo-ampere current pulses on nanosecond and microsecond scales. In both cases, the pulsed power devices used for the experiments had the same stored energy (˜500 J) and the wire mass was adjusted to optimize energy transfer to the shockwave. Laser backlit framing images of the shock front were achieved down to the radius of 30 μm. It was found that even in the case of initial azimuthal non-symmetry, the shock wave self-repairs in the final stages of its motion, leading to a highly uniform implosion. In both these and previous experiments, interference fringes have been observed in streak and framing images as the shockwave approached the axis. We have been able to accurately model the origin of the fringes, which is due to the propagation of the laser beam diffracting off the uniform converging shock front. The dynamics of the shockwave and its uniformity at small radii indicate that even with only 500 J stored energies, this technique should produce pressures above 1010 Pa on the axis, with temperatures and densities ideal for warm dense matter research.

  5. Single-shot full resolution region-of-interest (ROI) reconstruction in image plane digital holographic microscopy

    Science.gov (United States)

    Singh, Mandeep; Khare, Kedar

    2018-05-01

    We describe a numerical processing technique that allows single-shot region-of-interest (ROI) reconstruction in image plane digital holographic microscopy with full pixel resolution. The ROI reconstruction is modelled as an optimization problem where the cost function to be minimized consists of an L2-norm squared data fitting term and a modified Huber penalty term that are minimized alternately in an adaptive fashion. The technique can provide full pixel resolution complex-valued images of the selected ROI which is not possible to achieve with the commonly used Fourier transform method. The technique can facilitate holographic reconstruction of individual cells of interest from a large field-of-view digital holographic microscopy data. The complementary phase information in addition to the usual absorption information already available in the form of bright field microscopy can make the methodology attractive to the biomedical user community.

  6. The effect of increased irradiation uniformity on imprinting by 351-nm laser light

    International Nuclear Information System (INIS)

    Boehly, T.R.; Smalyuk, V.A.; Meyerhofer, D.D.; Knauer, J.P.; Bradley, D.K.; Verdon, C.P.; Kalantar, D.

    1997-01-01

    The acceleration-driven growth of perturbations initially seeded (or imprinted) by irradiation nonuniformities is a major concern for direct-drive ICF. We report on experiments where unperturbed, CH 2 targets were irradiated with 3-ns square pulses at 2x10 14 W/cm 2 using five overlapped UV beams. The uniformity of these beams was varied and subsequent unstable growth of irradiation imprinting was observed using time-gated x-radiography. We demonstrate that increased irradiation uniformity reduces imprinting, and we show the beneficial effects of distributed polarization rotators a new beam-smoothing device. In addition, we discuss experiments using a ' perturbing beam' to study the time dependence of imprinting. copyright 1997 American Institute of Physics

  7. Non-Uniform Sampling and J-UNIO Automation for Efficient Protein NMR Structure Determination.

    Science.gov (United States)

    Didenko, Tatiana; Proudfoot, Andrew; Dutta, Samit Kumar; Serrano, Pedro; Wüthrich, Kurt

    2015-08-24

    High-resolution structure determination of small proteins in solution is one of the big assets of NMR spectroscopy in structural biology. Improvements in the efficiency of NMR structure determination by advances in NMR experiments and automation of data handling therefore attracts continued interest. Here, non-uniform sampling (NUS) of 3D heteronuclear-resolved [(1)H,(1)H]-NOESY data yielded two- to three-fold savings of instrument time for structure determinations of soluble proteins. With the 152-residue protein NP_372339.1 from Staphylococcus aureus and the 71-residue protein NP_346341.1 from Streptococcus pneumonia we show that high-quality structures can be obtained with NUS NMR data, which are equally well amenable to robust automated analysis as the corresponding uniformly sampled data. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Application of a non-integer Bessel uniform approximation to inelastic molecular collisions

    International Nuclear Information System (INIS)

    Connor, J.N.L.; Mayne, H.R.

    1979-01-01

    A non-integer Bessel uniform approximation has been used to calculate transition probabilities for collinear atom-oscillator collisions. The collision systems used are a harmonic oscillator interacting via a Lennard-Jones potential and a Morse oscillator interacting via an exponential potential. Both classically allowed and classically forbidden transitions have been treated. The order of the Bessel function is chosen by a physical argument that makes use of information contained in the final-action initial-angle plot. Limitations of this procedure are discussed. It is shown that the non-integer Bessel approximation is accurate for elastic 0 → 0 collisions at high collision energies, where the integer Bessel approximation is inaccurate or inapplicable. (author)

  9. Beam Test of the ATLAS Level-1 Calorimeter Trigger System

    CERN Document Server

    Garvey, J; Mahout, G; Moye, T H; Staley, R J; Thomas, J P; Typaldos, D; Watkins, P M; Watson, A; Achenbach, R; Föhlisch, F; Geweniger, C; Hanke, P; Kluge, E E; Mahboubi, K; Meier, K; Meshkov, P; Rühr, F; Schmitt, K; Schultz-Coulon, H C; Ay, C; Bauss, B; Belkin, A; Rieke, S; Schäfer, U; Tapprogge, T; Trefzger, T; Weber, GA; Eisenhandler, E F; Landon, M; Apostologlou, P; Barnett, B M; Brawn, I P; Davis, A O; Edwards, J; Gee, C N P; Gillman, A R; Mirea, A; Perera, V J O; Qian, W; Sankey, D P C; Bohm, C; Hellman, S; Hidvegi, A; Silverstein, S

    2005-01-01

    The Level-1 Calorimter Trigger consists of a Preprocessor (PP), a Cluster Processor (CP), and a Jet/Energy-sum Processor (JEP). The CP and JEP receive digitised trigger-tower data from the Preprocessor and produce Region-of-Interest (RoIs) and trigger multiplicities. The latter are sent in real time to the Central Trigger Processor (CTP) where the Level-1 decision is made. On receipt of a Level-1 Accept, Readout Driver Modules (RODs), provide intermediate results to the data acquisition (DAQ) system for monitoring and diagnostic purpose. RoI information is sent to the RoI builder (RoIB) to help reduce the amount of data required for the Level-2 Trigger The Level-1 Calorimeter Trigger System at the test beam consisted of 1 Preprocessor module, 1 Cluster Processor Module, 1 Jet/Energy Module and 2 Common Merger Modules. Calorimeter energies were sucessfully handled thourghout the chain and trigger object sent to the CTP. Level-1 Accepts were sucessfully produced and used to drive the readout path. Online diagno...

  10. Dynamics of heavy ion beams during longitudinal compression

    International Nuclear Information System (INIS)

    Ho, D.D.M.; Bangerter, R.O.; Lee, E.P.; Brandon, S.; Mark, J.W.K.

    1987-01-01

    Heavy ion beams with initially uniform line charge density can be compressed longitudinally by an order of magnitude in such a way that the compressed beam has uniform line charge density and velocity-tilt profiles. There are no envelope mismatch oscillations during compression. Although the transverse temperature varies along the beam and also varies with time, no substantial longitudinal and transverse emittance growth has been observed. Scaling laws for beam radius and transport system parameters are given

  11. Geometry Effects on Multipole Components and Beam Optics in High-Velocity Multi-Spoke Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Hopper, Christopher S. [ODU, JLAB; Deitrick, Kirsten E. [ODU, JLAB; Delayen, Jean R. [ODU, JLAB

    2013-12-01

    Velocity-of-light, multi-spoke cavities are being proposed to accelerate electrons in a compact light-source. There are strict requirements on the beam quality which require that the linac have only small non-uniformities in the accelerating field. Beam dynamics simulations have uncovered varying levels of focusing and defocusing in the proposed cavities, which is dependent on the geometry of the spoke in the vicinity of the beam path. Here we present results for the influence different spoke geometries have on the multipole components of the accelerating field and how these components, in turn, impact the simulated beam properties.

  12. Shutterless non-uniformity correction for the long-term stability of an uncooled long-wave infrared camera

    Science.gov (United States)

    Liu, Chengwei; Sui, Xiubao; Gu, Guohua; Chen, Qian

    2018-02-01

    For the uncooled long-wave infrared (LWIR) camera, the infrared (IR) irradiation the focal plane array (FPA) receives is a crucial factor that affects the image quality. Ambient temperature fluctuation as well as system power consumption can result in changes of FPA temperature and radiation characteristics inside the IR camera; these will further degrade the imaging performance. In this paper, we present a novel shutterless non-uniformity correction method to compensate for non-uniformity derived from the variation of ambient temperature. Our method combines a calibration-based method and the properties of a scene-based method to obtain correction parameters at different ambient temperature conditions, so that the IR camera performance can be less influenced by ambient temperature fluctuation or system power consumption. The calibration process is carried out in a temperature chamber with slowly changing ambient temperature and a black body as uniform radiation source. Enough uniform images are captured and the gain coefficients are calculated during this period. Then in practical application, the offset parameters are calculated via the least squares method based on the gain coefficients, the captured uniform images and the actual scene. Thus we can get a corrected output through the gain coefficients and offset parameters. The performance of our proposed method is evaluated on realistic IR images and compared with two existing methods. The images we used in experiments are obtained by a 384× 288 pixels uncooled LWIR camera. Results show that our proposed method can adaptively update correction parameters as the actual target scene changes and is more stable to temperature fluctuation than the other two methods.

  13. Radiologic-pathologic analysis of quantitative 3D tumour enhancement on contrast-enhanced MR imaging: a study of ROI placement

    International Nuclear Information System (INIS)

    Chockalingam, Arun; Duran, Rafael; Sohn, Jae Ho; Schernthaner, Ruediger; Chapiro, Julius; Lee, Howard; Sahu, Sonia; Nguyen, Sonny; Geschwind, Jean-Francois; Lin, MingDe

    2016-01-01

    To investigate the influence of region-of-interest (ROI) placement on 3D tumour enhancement [Quantitative European Association for the Study of the Liver (qEASL)] in hepatocellular carcinoma (HCC) patients treated with transcatheter arterial chemoembolization (TACE). Phase 1: 40 HCC patients had nine ROIs placed by one reader using systematic techniques (3 ipsilateral to the lesion, 3 contralateral to the lesion, and 3 dispersed throughout the liver) and qEASL variance was measured. Intra-class correlations were computed. Phase 2: 15 HCC patients with histosegmentation were selected. Six ROIs were systematically placed by AC (3 ROIs ipsilateral and 3 ROIs contralateral to the lesion). Three ROIs were placed by 2 radiologists. qEASL values were compared to histopathology by Pearson's correlation, linear regression, and median difference. Phase 1: The dispersed method (abandoned in phase 2) had low consistency and high variance. Phase 2: qEASL correlated strongly with pathology in systematic methods [Pearson's correlation coefficient = 0.886 (ipsilateral) and 0.727 (contralateral)] and in clinical methods (0.625 and 0.879). However, ipsilateral placement matched best with pathology (median difference: 5.4 %; correlation: 0.89; regression CI: [0.904, 0.1409]). qEASL is a robust method with comparable values among tested placements. Ipsilateral placement showed high consistency and better pathological correlation. (orig.)

  14. A Fast Non Intercepting Linac Electron Beam Position and Current Monitor

    DEFF Research Database (Denmark)

    Hansen, Jørgen-Walther; Wille, Mads

    1982-01-01

    A non-intercepting beam monitor consisting of four detecting loops is used to determine the spatial postion and current of a pulsed beam from an electron linear accelerator. The monitor detects the magnetic field radiated by the substructure of the electron bunches created by the accelerating...

  15. The uniformity study of non-oxide thin film at device level using electron energy loss spectroscopy

    Science.gov (United States)

    Li, Zhi-Peng; Zheng, Yuankai; Li, Shaoping; Wang, Haifeng

    2018-05-01

    Electron energy loss spectroscopy (EELS) has been widely used as a chemical analysis technique to characterize materials chemical properties, such as element valence states, atoms/ions bonding environment. This study provides a new method to characterize physical properties (i.e., film uniformity, grain orientations) of non-oxide thin films in the magnetic device by using EELS microanalysis on scanning transmission electron microscope. This method is based on analyzing white line ratio of spectra and related extended energy loss fine structures so as to correlate it with thin film uniformity. This new approach can provide an effective and sensitive method to monitor/characterize thin film quality (i.e., uniformity) at atomic level for thin film development, which is especially useful for examining ultra-thin films (i.e., several nanometers) or embedded films in devices for industry applications. More importantly, this technique enables development of quantitative characterization of thin film uniformity and it would be a remarkably useful technique for examining various types of devices for industrial applications.

  16. Non-uniform sampling and wide range angular spectrum method

    International Nuclear Information System (INIS)

    Kim, Yong-Hae; Byun, Chun-Won; Oh, Himchan; Lee, JaeWon; Pi, Jae-Eun; Heon Kim, Gi; Lee, Myung-Lae; Ryu, Hojun; Chu, Hye-Yong; Hwang, Chi-Sun

    2014-01-01

    A novel method is proposed for simulating free space field propagation from a source plane to a destination plane that is applicable for both small and large propagation distances. The angular spectrum method (ASM) was widely used for simulating near field propagation, but it caused a numerical error when the propagation distance was large because of aliasing due to under sampling. Band limited ASM satisfied the Nyquist condition on sampling by limiting a bandwidth of a propagation field to avoid an aliasing error so that it could extend the applicable propagation distance of the ASM. However, the band limited ASM also made an error due to the decrease of an effective sampling number in a Fourier space when the propagation distance was large. In the proposed wide range ASM, we use a non-uniform sampling in a Fourier space to keep a constant effective sampling number even though the propagation distance is large. As a result, the wide range ASM can produce simulation results with high accuracy for both far and near field propagation. For non-paraxial wave propagation, we applied the wide range ASM to a shifted destination plane as well. (paper)

  17. The Study on Bone Mineral Density Measurement Error in Accordance with Change in ROI by Utilizing Dual Energy X-ray Absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yun Hong [Dept. of Diagnostic Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Lee, In Ja [Dept. of Radiological Technology, Dongnam Health College, Suwon (Korea, Republic of); Yong, Hyung Jin [Dept. of Medicine Physics, The Graduate School of Biomedical Science Korea University, Seoul (Korea, Republic of)

    2012-03-15

    Dual Energy X-ray Absorptiometry(DEXA) is commonly used to diagnose Osteoporosis. The errors of DEXA bone density operation are caused by operator, bone mineral density meter, blood testing, patient. We focus on operator error then study about how much influence operator's region of intest(ROI) in bone testing result. During from March to July in 2011. 50 patients ware selected respectively from 30, 40, 50, 60, and 70 age groups who came to Korea University Medical Center(KUMC) for their Osteoporosis treatment. A-test was performed with usually ROI and B-test was performed with most widely ROI. Then, We compare A-test and B-test for find maximum difference of T-score error which occurred operator ROI controlling. Standard deviation of T-score of B-test showed 0.1 higher then A-test in femur neck. Standard deviation of B-test showed 0.2 higher then A-test in Ward's area which in Greater trocanter and Inter trocanter. Standard deviation of B-test showed 0,1 lower then A-test in L-1. Bone density testing about Two hundred patients results are as follow. When operator ROI was changed wider than normal ROI, bone density of femur was measured more higher but bone density of L-spine was measured more lower then normal bone density. That means, sometime DEXA bone density testing result is dependent by operator ROI controlling. This is relevant with the patient's medicine and health insurance, thus, tester always keep the size of ROI for to prevent any problem in the patient.

  18. Uniform Decay for Solutions of an Axially Moving Viscoelastic Beam

    Energy Technology Data Exchange (ETDEWEB)

    Kelleche, Abdelkarim, E-mail: kellecheabdelkarim@gmail.com [Université des Sciences et de la Technologie Houari Boumediene, Faculté des Mathématiques (Algeria); Tatar, Nasser-eddine, E-mail: tatarn@Kfupm.edu.sa [King Fahd University of Petroleum and Minerals, Department of Mathematics and Statistics (Saudi Arabia)

    2017-06-15

    The paper deals with an axially moving viscoelastic structure modeled as an Euler–Bernoulli beam. The aim is to suppress the transversal displacement (transversal vibrations) that occur during the axial motion of the beam. It is assumed that the beam is moving with a constant axial speed and it is subject to a nonlinear force at the right boundary. We prove that when the axial speed of the beam is smaller than a critical value, the dissipation produced by the viscoelastic material is sufficient to suppress the transversal vibrations. It is shown that the rate of decay of the energy depends on the kernel which arise in the viscoelastic term. We consider a general kernel and notice that solutions cannot decay faster than the kernel.

  19. Cell-centered particle weighting algorithm for PIC simulations in a non-uniform 2D axisymmetric mesh

    Science.gov (United States)

    Araki, Samuel J.; Wirz, Richard E.

    2014-09-01

    Standard area weighting methods for particle-in-cell simulations result in systematic errors on particle densities for a non-uniform mesh in cylindrical coordinates. These errors can be significantly reduced by using weighted cell volumes for density calculations. A detailed description on the corrected volume calculations and cell-centered weighting algorithm in a non-uniform mesh is provided. The simple formulas for the corrected volume can be used for any type of quadrilateral and/or triangular mesh in cylindrical coordinates. Density errors arising from the cell-centered weighting algorithm are computed for radial density profiles of uniform, linearly decreasing, and Bessel function in an adaptive Cartesian mesh and an unstructured mesh. For all the density profiles, it is shown that the weighting algorithm provides a significant improvement for density calculations. However, relatively large density errors may persist at outermost cells for monotonically decreasing density profiles. A further analysis has been performed to investigate the effect of the density errors in potential calculations, and it is shown that the error at the outermost cell does not propagate into the potential solution for the density profiles investigated.

  20. Synchronization in a non-uniform network of excitatory spiking neurons

    Science.gov (United States)

    Echeveste, Rodrigo; Gros, Claudius

    Spontaneous synchronization of pulse coupled elements is ubiquitous in nature and seems to be of vital importance for life. Networks of pacemaker cells in the heart, extended populations of southeast asian fireflies, and neuronal oscillations in cortical networks, are examples of this. In the present work, a rich repertoire of dynamical states with different degrees of synchronization are found in a network of excitatory-only spiking neurons connected in a non-uniform fashion. In particular, uncorrelated and partially correlated states are found without the need for inhibitory neurons or external currents. The phase transitions between these states, as well the robustness, stability, and response of the network to external stimulus are studied.

  1. Refractive waveguide non-mechanical beam steering (NMBS) in the MWIR

    Science.gov (United States)

    Myers, Jason D.; Frantz, Jesse A.; Spillmann, Christopher M.; Bekele, Robel Y.; Kolacz, Jakub; Gotjen, Henry; Naciri, Jawad; Shaw, Brandon; Sanghera, Jas S.

    2018-02-01

    Beam steering is a crucial technology for a number of applications, including chemical sensing/mapping and light detection and ranging (LIDAR). Traditional beam steering approaches rely on mechanical movement, such as the realignment of mirrors in gimbal mounts. The mechanical approach to steering has several drawbacks, including large size, weight and power usage (SWAP), and frequent mechanical failures. Recently, alternative non-mechanical approaches have been proposed and developed, but these technologies do not meet the demanding requirements for many beam steering applications. Here, we highlight the development efforts into a particular non-mechanical beam steering (NMBS) approach, refractive waveguides, for application in the MWIR. These waveguides are based on an Ulrich-coupled slab waveguide with a liquid crystal (LC) top cladding; by selectively applying an electric field across the liquid crystal through a prismatic electrode, steering is achieved by creating refraction at prismatic interfaces as light propagates through the device. For applications in the MWIR, we describe a versatile waveguide architecture based on chalcogenide glasses that have a wide range of refractive indices, transmission windows, and dispersion properties. We have further developed robust shadow-masking methods to taper the subcladding layers in the coupling region. We have demonstrated devices with >10° of steering in the MWIR and a number of advantageous properties for beam steering applications, including low-power operation, compact size, and fast point-to-point steering.

  2. A generic Approach for Reliability Predictions considering non-uniformly Deterioration Behaviour

    International Nuclear Information System (INIS)

    Krause, Jakob; Kabitzsch, Klaus

    2012-01-01

    Predictive maintenance offers the possibility to prognosticate the remaining time until a maintenance action of a machine has to be scheduled. Unfortunately, current predictive maintenance solutions are only suitable for very specific use cases like reliability predictions based on vibration monitoring. Furthermore, they do not consider the fact that machines may deteriorate non-uniformly, depending on external influences (e.g., the work piece material in a milling machine or the changing fruit acid concentration in a bottling plant). In this paper two concepts for a generic predictive maintenance solution which also considers non-uniformly aging behaviour are introduced. The first concept is based on system models representing the health state of a technical system. As these models are usually statically (viz. without a timely dimension) their coefficients are determined periodically and the resulting time series is used as aging indicator. The second concept focuses on external influences (contexts) which change the behaviour of the previous mentioned aging indicators in order to increase the accuracy of reliability predictions. Therefore, context-depended time series models are determined and used to predict machine reliability. Both concepts were evaluated on data of an air ventilation system. Thereby, it could be shown that they are suitable to determine aging indicators in a generic way and to incorporate external influences in the reliability prediction. Through this, the quality of reliability predictions can be significantly increased. In reality this leads to a more accurate scheduling of maintenance actions. Furthermore, the generic character of the solutions makes the concepts suitable for a wide range of aging processes.

  3. Propagation of the Lissajous singularity dipole emergent from non-paraxial polychromatic beams

    Science.gov (United States)

    Haitao, Chen; Gao, Zenghui; Wang, Wanqing

    2017-06-01

    The propagation of the Lissajous singularity dipole (LSD) emergent from the non-paraxial polychromatic beams is studied. It is found that the handedness reversal of Lissajous singularities, the change in the shape of Lissajous figures, as well as the creation and annihilation of the LSD may take place by varying the propagation distance, off-axis parameter, wavelength, or amplitude factor. Comparing with the LSD emergent from paraxial polychromatic beams, the output field of non-paraxial polychromatic beams is more complicated, which results in some richer dynamic behaviors of Lissajous singularities, such as more Lissajous singularities and no vanishing of a single Lissajous singularity at the plane z>0.

  4. Uniform deposition of size-selected clusters using Lissajous scanning

    International Nuclear Information System (INIS)

    Beniya, Atsushi; Watanabe, Yoshihide; Hirata, Hirohito

    2016-01-01

    Size-selected clusters can be deposited on the surface using size-selected cluster ion beams. However, because of the cross-sectional intensity distribution of the ion beam, it is difficult to define the coverage of the deposited clusters. The aggregation probability of the cluster depends on coverage, whereas cluster size on the surface depends on the position, despite the size-selected clusters are deposited. It is crucial, therefore, to deposit clusters uniformly on the surface. In this study, size-selected clusters were deposited uniformly on surfaces by scanning the cluster ions in the form of Lissajous pattern. Two sets of deflector electrodes set in orthogonal directions were placed in front of the sample surface. Triangular waves were applied to the electrodes with an irrational frequency ratio to ensure that the ion trajectory filled the sample surface. The advantages of this method are simplicity and low cost of setup compared with raster scanning method. The authors further investigated CO adsorption on size-selected Pt n (n = 7, 15, 20) clusters uniformly deposited on the Al 2 O 3 /NiAl(110) surface and demonstrated the importance of uniform deposition.

  5. Uniform deposition of size-selected clusters using Lissajous scanning

    Energy Technology Data Exchange (ETDEWEB)

    Beniya, Atsushi; Watanabe, Yoshihide, E-mail: e0827@mosk.tytlabs.co.jp [Toyota Central R& D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192 (Japan); Hirata, Hirohito [Toyota Motor Corporation, 1200 Mishuku, Susono, Shizuoka 410-1193 (Japan)

    2016-05-15

    Size-selected clusters can be deposited on the surface using size-selected cluster ion beams. However, because of the cross-sectional intensity distribution of the ion beam, it is difficult to define the coverage of the deposited clusters. The aggregation probability of the cluster depends on coverage, whereas cluster size on the surface depends on the position, despite the size-selected clusters are deposited. It is crucial, therefore, to deposit clusters uniformly on the surface. In this study, size-selected clusters were deposited uniformly on surfaces by scanning the cluster ions in the form of Lissajous pattern. Two sets of deflector electrodes set in orthogonal directions were placed in front of the sample surface. Triangular waves were applied to the electrodes with an irrational frequency ratio to ensure that the ion trajectory filled the sample surface. The advantages of this method are simplicity and low cost of setup compared with raster scanning method. The authors further investigated CO adsorption on size-selected Pt{sub n} (n = 7, 15, 20) clusters uniformly deposited on the Al{sub 2}O{sub 3}/NiAl(110) surface and demonstrated the importance of uniform deposition.

  6. Realization of high irradiation uniformity for direct drive ICF at the SG-III prototype laser facility

    International Nuclear Information System (INIS)

    Tian, C.; Shan, L.; Zhang, B.; Zhou, W.; Liu, D.; Bi, B.; Zhang, F.; Wang, W.; Zhang, B.; Giu, Y.

    2015-01-01

    The direct drive irradiation uniformity during the initial imprinting phase at the SG-III prototype laser facility is analyzed and optimized with different methods. At first, the polar direct drive technique is applied to reduce the root mean square deviation σ from 16.1% to 6.4%. To further reduce the non-uniformity, we propose a new method by adjusting the intensity distribution of the laser spot. The overlap of laser beams on the capsule surface is studied and a factor is introduced to adjust the intensity of the laser spot for achieving absolute irradiation uniformity while bringing wild intensity change at laser spot edges. Noting that the overlapping region at the capsule surface is symmetrically distributed, the contribution of light from the edge of a spot can be transferred to its own internal. The newly adjusted intensity distributes at two main regions and the intensity varies slowly and continuously in each, further reducing σ to about 0.35%. Taken into account that the adjusted intensity has very sharp steps, super-Gaussian spatial profiles are used to approximate the required intensity to make it more practicable, which leads σ to 0.94%. Furthermore, sensitivity analysis to beam errors is performed and results show that this scheme can tolerate a certain amount of uncertainties. (authors)

  7. Influence of Non-uniform Temperature Field on Spectra of Fibre Bragg Grating

    International Nuclear Information System (INIS)

    Yan, Zhou; Xing-Fang, He; Xiao-Yong, Fang; Jie, Yuan; Li-Qun, Yin; Mao-Sheng, Cao

    2009-01-01

    We simulate the spectrum characteristics of fibre Bragg grating (FBG) with non-uniform temperature using the transmission matrix method, and the results are analysed. It is found that firstly the modulated coefficient of average refractive index is a very important parameter that influences the spectrum characteristic of the fibre Bragg grating, and secondly the spectrum curves are different in different temperature fields at the same parameter. Hence, we can determine the metrical temperature by analysing the spectrum of fibre Bragg grating

  8. Numerical analysis of blood flow in realistic arteries subjected to strong non-uniform magnetic fields

    NARCIS (Netherlands)

    Kenjeres, S.

    2008-01-01

    The paper reports on a comprehensive mathematical model for simulations of blood flow under the presence of strong non-uniform magnetic fields. The model consists of a set of Navier–Stokes equations accounting for the Lorentz and magnetisation forces, and a simplified set of Maxwell’s equations

  9. Impact of roof height non-uniformity on pollutant transport between a street canyon and intersections.

    Science.gov (United States)

    Nosek, Štěpán; Kukačka, Libor; Jurčáková, Klára; Kellnerová, Radka; Jaňour, Zbyněk

    2017-08-01

    This paper presents an extension of our previous wind-tunnel study (Nosek et al., 2016) in which we highlighted the need for investigation of the removal mechanisms of traffic pollution from all openings of a 3D street canyon. The extension represents the pollution flux (turbulent and advective) measurements at the lateral openings of three different 3D street canyons for the winds perpendicular and oblique to the along-canyon axis. The pollution was simulated by emitting a passive gas (ethane) from a homogeneous ground-level line source positioned along the centreline of the investigated street canyons. The street canyons were formed by courtyard-type buildings of two different regular urban-array models. The first model has a uniform building roof height, while the second model has a non-uniform roof height along each building's wall. The mean flow and concentration fields at the canyons' lateral openings confirm the findings of other studies that the buildings' roof-height variability at the intersections plays an important role in the dispersion of the traffic pollutants within the canyons. For the perpendicular wind, the non-uniform roof-height canyon appreciably removes or entrains the pollutant through its lateral openings, contrary to the uniform canyon, where the pollutant was removed primarily through the top. The analysis of the turbulent mass transport revealed that the coherent flow structures of the lateral momentum transport correlate with the ventilation processes at the lateral openings of all studied canyons. These flow structures coincide at the same areas and hence simultaneously transport the pollutant in opposite directions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Three dimensional peristaltic flow of hyperbolic tangent fluid in non-uniform channel having flexible walls

    Directory of Open Access Journals (Sweden)

    M. Ali Abbas

    2016-03-01

    Full Text Available In this present analysis, three dimensional peristaltic flow of hyperbolic tangent fluid in a non-uniform channel has been investigated. We have considered that the pressure is uniform over the whole cross section and the interial effects have been neglected. For this purpose we consider laminar flow under the assumptions of long wavelength (λ→∞ and creeping flow (Re→0 approximations. The attained highly nonlinear equations are solved with the help of Homotopy perturbation method. The influence of various physical parameters of interest is demonstrated graphically for wall tension, mass characterization, damping nature of the wall, wall rigidity, wall elastance, aspect ratio and the Weissenberg number. In this present investigation we found that the magnitude of the velocity is maximum in the center of the channel whereas it is minimum near the walls. Stream lines are also drawn to discuss the trapping mechanism for all the physical parameters. Comparison has also been presented between Newtonian and non-Newtonian fluid.

  11. Proton-beam energy analyzer

    International Nuclear Information System (INIS)

    Belan, V.N.; Bolotin, L.I.; Kiselev, V.A.; Linnik, A.F.; Uskov, V.V.

    1989-01-01

    The authors describe a magnetic analyzer for measurement of proton-beam energy in the range from 100 keV to 25 MeV. The beam is deflected in a uniform transverse magnetic field and is registered by photographing a scintillation screen. The energy spectrum of the beam is constructed by microphotometry of the photographic film

  12. Unified analytical threshold voltage model for non-uniformly doped dual metal gate fully depleted silicon-on-insulator MOSFETs

    Science.gov (United States)

    Rao, Rathnamala; Katti, Guruprasad; Havaldar, Dnyanesh S.; DasGupta, Nandita; DasGupta, Amitava

    2009-03-01

    The paper describes the unified analytical threshold voltage model for non-uniformly doped, dual metal gate (DMG) fully depleted silicon-on-insulator (FDSOI) MOSFETs based on the solution of 2D Poisson's equation. 2D Poisson's equation is solved analytically for appropriate boundary conditions using separation of variables technique. The solution is then extended to obtain the threshold voltage of the FDSOI MOSFET. The model is able to handle any kind of non-uniform doping, viz. vertical, lateral as well as laterally asymetric channel (LAC) profile in the SOI film in addition to the DMG structure. The analytical results are validated with the numerical simulations using the device simulator MEDICI.

  13. Assessment of Structural Behavior of Non-corroded and Corroded RCC Beams Using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Anand Parande

    2008-09-01

    Full Text Available A three dimensional finite element model is developed to examine the structural behaviour of corroded reinforced concrete beam and non corroded reinforced concrete beam. Non linear finite element analysis is performed using the ANSYS program. SOLID 65, LINK 8 element represent concrete and discrete reinforcing steel bars, based on each component actual characteristics, non linear material properties are defined for both elements. The effect of corrosion in reinforced concrete is studied by finite element analysis; an approach is developed to model the corrosion product expansion causing concrete cover cracking for this, beam has been modeled using ANSYS and using this data the beam has been casted with M20 concrete after 28 days the beam will be tested for flexural strength. The comparison between ANSYS prediction and field data are made in terms of deflection, stress, strain, bond strength and crack pattern of concrete beam.

  14. Laser beam-forming by deformable mirror for laser isotope separation

    International Nuclear Information System (INIS)

    Nemoto, Koshichi; Fujii, Takashi; Goto, Naohiko

    1995-01-01

    A rectangular laser beam of uniform intensity is very suitable for laser isotope separation. In this paper, we propose a beam-forming system which consists two deformable mirrors. One of the mirrors changes the beam intensity and the other compensates for phase distortion. We developed a deformable mirror for beam-forming. Its deformed surface is similar to the ideal mirror surface for beam-forming. We reshaped a Gaussian-like He-Ne laser beam into a beam with a more uniform intensity profile by a simple deformable mirror. (author)

  15. Analysis of Causes of Non-Uniform Flow Distribution in Manifold Systems with Variable Flow Rate along Length

    Science.gov (United States)

    Zemlyanaya, N. V.; Gulyakin, A. V.

    2017-11-01

    The uniformity of flow distribution in perforated manifolds is a relevant task. The efficiency of water supply, sewerage and perflation systems is determined by hydraulics of the flow with a variable mass. The extensive study of versatile available information showed that achieving a uniform flow distribution through all of the outlets is almost impossible. The analysis of the studies conducted by other authors and our numerical experiments performed with the help of the software package ANSYS 16.1 were made in this work. The results allowed us to formulate the main causes of non-uniform flow distribution. We decided to suggest a hypothesis to explain the static pressure rise problem at the end of a perforated manifold.

  16. Spot size characterization of focused non-Gaussian X-ray laser beams

    NARCIS (Netherlands)

    Chalupsky, J.; Krzywinski, J.; Juha, L.; Hajkova, V.; Cihelka, J.; Burian, T.; Vysin, L.; Gaudin, J.; Gleeson, A.; Jurek, M.; Khorsand, A. R.; Klinger, D.; Wabnitz, H.; Sobierajski, R.; Stormer, M.; Tiedtke, K.; Toleikis, S.

    2010-01-01

    We present a new technique for the characterization of non-Gaussian laser beams which cannot be described by an analytical formula. As a generalization of the beam spot area we apply and refine the definition of so called effective area (A(eff)) [1] in order to avoid using the full-width at half

  17. Radiometric Non-Uniformity Characterization and Correction of Landsat 8 OLI Using Earth Imagery-Based Techniques

    Directory of Open Access Journals (Sweden)

    Frank Pesta

    2014-12-01

    Full Text Available Landsat 8 is the first satellite in the Landsat mission to acquire spectral imagery of the Earth using pushbroom sensor instruments. As a result, there are almost 70,000 unique detectors on the Operational Land Imager (OLI alone to monitor. Due to minute variations in manufacturing and temporal degradation, every detector will exhibit a different behavior when exposed to uniform radiance, causing a noticeable striping artifact in collected imagery. Solar collects using the OLI’s on-board solar diffuser panels are the primary method of characterizing detector level non-uniformity. This paper reports on an approach for using a side-slither maneuver to estimate relative detector gains within each individual focal plane module (FPM in the OLI. A method to characterize cirrus band detector-level non-uniformity using deep convective clouds (DCCs is also presented. These approaches are discussed, and then, correction results are compared with the diffuser-based method. Detector relative gain stability is assessed using the side-slither technique. Side-slither relative gains were found to correct streaking in test imagery with quality comparable to diffuser-based gains (within 0.005% for VNIR/PAN; 0.01% for SWIR and identified a 0.5% temporal drift over a year. The DCC technique provided relative gains that visually decreased striping over the operational calibration in many images.

  18. Reconstructing cone-beam CT with spatially varying qualities for adaptive radiotherapy: a proof-of-principle study.

    Science.gov (United States)

    Lu, Wenting; Yan, Hao; Gu, Xuejun; Tian, Zhen; Luo, Ouyang; Yang, Liu; Zhou, Linghong; Cervino, Laura; Wang, Jing; Jiang, Steve; Jia, Xun

    2014-10-21

    With the aim of maximally reducing imaging dose while meeting requirements for adaptive radiation therapy (ART), we propose in this paper a new cone beam CT (CBCT) acquisition and reconstruction method that delivers images with a low noise level inside a region of interest (ROI) and a relatively high noise level outside the ROI. The acquired projection images include two groups: densely sampled projections at a low exposure with a large field of view (FOV) and sparsely sampled projections at a high exposure with a small FOV corresponding to the ROI. A new algorithm combining the conventional filtered back-projection algorithm and the tight-frame iterative reconstruction algorithm is also designed to reconstruct the CBCT based on these projection data. We have validated our method on a simulated head-and-neck (HN) patient case, a semi-real experiment conducted on a HN cancer patient under a full-fan scan mode, as well as a Catphan phantom under a half-fan scan mode. Relative root-mean-square errors (RRMSEs) of less than 3% for the entire image and ~1% within the ROI compared to the ground truth have been observed. These numbers demonstrate the ability of our proposed method to reconstruct high-quality images inside the ROI. As for the part outside ROI, although the images are relatively noisy, it can still provide sufficient information for radiation dose calculations in ART. Dose distributions calculated on our CBCT image and on a standard CBCT image are in agreement, with a mean relative difference of 0.082% inside the ROI and 0.038% outside the ROI. Compared with the standard clinical CBCT scheme, an imaging dose reduction of approximately 3-6 times inside the ROI was achieved, as well as an 8 times outside the ROI. Regarding computational efficiency, it takes 1-3 min to reconstruct a CBCT image depending on the number of projections used. These results indicate that the proposed method has the potential for application in ART.

  19. Devaney's chaos on uniform limit maps

    International Nuclear Information System (INIS)

    Yan Kesong; Zeng Fanping; Zhang Gengrong

    2011-01-01

    Highlights: → The transitivity may not been inherited even if the sequence functions mixing. → The sensitivity may not been inherited even if the iterates of sequence have some uniform convergence. → Some equivalence conditions for the transitivity and sensitivity for uniform limit function are given. → A non-transitive sequence may converge uniformly to a transitive map. - Abstract: Let (X, d) be a compact metric space and f n : X → X a sequence of continuous maps such that (f n ) converges uniformly to a map f. The purpose of this paper is to study the Devaney's chaos on the uniform limit f. On the one hand, we show that f is not necessarily transitive even if all f n mixing, and the sensitive dependence on initial conditions may not been inherited to f even if the iterates of the sequence have some uniform convergence, which correct two wrong claims in . On the other hand, we give some equivalence conditions for the uniform limit f to be transitive and to have sensitive dependence on initial conditions. Moreover, we present an example to show that a non-transitive sequence may converge uniformly to a transitive map.

  20. Uniform and non-uniform inlet temperature of a vertical hot water jet injected into a rectangular tank

    KAUST Repository

    El-Amin, Mohamed; Sun, Shuyu

    2010-01-01

    In most of real-world applications, such as the case of heat stores, inlet is not kept at a constant temperature but it may vary with time during charging process. In this paper, a vertical water jet injected into a rectangular storage tank is measured experimentally and simulated numerically. Two cases of study are considered; one is a hot water jet with uniform inlet temperature (UIT) injected into a cold water tank, and the other is a cold water jet with non-uniform inlet temperature (NUIT) injected into a hot water tank. Three different temperature differences and three different flow rates are studied for the hot water jet with UIT which is injected into a cold water tank. Also, three different initial temperatures with constant flow rate as well as three different flow rates with constant initial temperature are considered for the cold jet with NUIT which is injected into a hot water tank. Turbulence intensity at the inlet as well as Reynolds number for the NUIT cases are therefore functions of inlet temperature and time. Both experimental measurements and numerical calculations are carried out for the same measured flow and thermal conditions. The realizable k-ε model is used for modeling the turbulent flow. Numerical solutions are obtained for unsteady flow while pressure, velocity, temperature and turbulence distributions inside the water tank are analyzed. The simulated results are compared to the measured results, and they show a good agreement at low temperatures. © 2010 IEEE.

  1. Uniform and non-uniform inlet temperature of a vertical hot water jet injected into a rectangular tank

    KAUST Repository

    El-Amin, Mohamed

    2010-12-01

    In most of real-world applications, such as the case of heat stores, inlet is not kept at a constant temperature but it may vary with time during charging process. In this paper, a vertical water jet injected into a rectangular storage tank is measured experimentally and simulated numerically. Two cases of study are considered; one is a hot water jet with uniform inlet temperature (UIT) injected into a cold water tank, and the other is a cold water jet with non-uniform inlet temperature (NUIT) injected into a hot water tank. Three different temperature differences and three different flow rates are studied for the hot water jet with UIT which is injected into a cold water tank. Also, three different initial temperatures with constant flow rate as well as three different flow rates with constant initial temperature are considered for the cold jet with NUIT which is injected into a hot water tank. Turbulence intensity at the inlet as well as Reynolds number for the NUIT cases are therefore functions of inlet temperature and time. Both experimental measurements and numerical calculations are carried out for the same measured flow and thermal conditions. The realizable k-ε model is used for modeling the turbulent flow. Numerical solutions are obtained for unsteady flow while pressure, velocity, temperature and turbulence distributions inside the water tank are analyzed. The simulated results are compared to the measured results, and they show a good agreement at low temperatures. © 2010 IEEE.

  2. Language pathway tracking: comparing nTMS-based DTI fiber tracking with a cubic ROIs-based protocol.

    Science.gov (United States)

    Negwer, Chiara; Sollmann, Nico; Ille, Sebastian; Hauck, Theresa; Maurer, Stefanie; Kirschke, Jan S; Ringel, Florian; Meyer, Bernhard; Krieg, Sandro M

    2017-03-01

    OBJECTIVE Diffusion tensor imaging (DTI) fiber tracking (FT) has been widely used in glioma surgery in recent years. It can provide helpful information about subcortical structures, especially in patients with eloquent space-occupying lesions. This study compared the newly developed navigated transcranial magnetic stimulation (nTMS)-based DTI FT of language pathways with the most reproducible protocol for language pathway tractography, using cubic regions of interest (ROIs) for the arcuate fascicle. METHODS Thirty-seven patients with left-sided perisylvian lesions underwent language mapping by repetitive nTMS. DTI FT was performed using the cubic ROIs-based protocol and the authors' nTMS-based DTI FT approach. The same minimal fiber length and fractional anisotropy were chosen (50 mm and 0.2, respectively). Both protocols were performed with standard clinical tractography software. RESULTS Both methods visualized language-related fiber tracts (i.e., corticonuclear tract, arcuate fascicle, uncinate fascicle, superior longitudinal fascicle, inferior longitudinal fascicle, arcuate fibers, commissural fibers, corticothalamic fibers, and frontooccipital fascicle) in all 37 patients. Using the cubic ROIs-based protocol, 39.9% of these language-related fiber tracts were detected in the examined patients, as opposed to 76.0% when performing nTMS-based DTI FT. For specifically tracking the arcuate fascicle, however, the cubic ROIs-based approach showed better results (97.3% vs 75.7% with nTMS-based DTI FT). CONCLUSIONS The cubic ROIs-based protocol was designed for arcuate fascicle tractography, and this study shows that it is still useful for this intention. However, superior results were obtained using the nTMS-based DTI FT for visualization of other language-related fiber tracts.

  3. Wavelength-independent laser beam shaping

    CSIR Research Space (South Africa)

    Degama, MP

    2010-07-01

    Full Text Available This paper presents a beam shaping device namely, a Diffractive Optical Element (DOE), which is used to change a beam having a Gaussian intensity profile into a beam with a uniform intensity profile. The DOE used in this work was fabricated from Zn...

  4. Effect of annealing, thickness ratio and bend angle on springback of AA6061-T6 with non-uniform thickness section

    Directory of Open Access Journals (Sweden)

    Adnan M.F.

    2017-01-01

    Full Text Available Non-uniform thickness section section is considered one of the most effective approaches to reduce automotive part weight. Reduction in term of mass and size result in less fuel consumption and greenhouse gases. Thickness is the most significant parameter to formability, therefore forming a section with non-uniform thickness becomes a great challenge. Improper process and incorrect decision may lead to severe defect and one of the main concerns is the springback. This study will focus on springback behaviour of non-uniform thickness AA6061 strip with complex profile using Taguchi Method. Profile projector (PC 3000 is used to measure the spring back and two-line technique is applied to measure angles (after loading between two lines. Three parameters (i.e. annealing temperature, thickness ratio and bend angle are studied, and results determine that the most significant parameter is bend angle, followed by thickness ratio, and then by the annealing temperature of the specimen during bending process.

  5. Non-Uniform Free-Free Absorption in the GPS Radio Galaxy 0108+388

    CERN Document Server

    Marr, J M; Crawford, F

    2001-01-01

    We have observed the canonical gigahertz-peaked spectrum source 0108+388 with the VLBA at a range of frequencies above and below the spectral peak. The activity that dominates the radio emission from 0108+388, which is also classified as a Compact Symmetric Object, is thought to be less than 1000 years old. We present strong evidence that the spectral turnover in 0108+388 results from free-free absorption by non-uniform gas, possibly in the form of a disk in the central tens of parsecs.

  6. Non-paraxial beam to push and pull microparticles

    DEFF Research Database (Denmark)

    Novitsky, Andrey; Qiu, C.-W.

    2011-01-01

    We discuss a feasibility of the pulling (backward) force acting on a spherical microparticle in a non-paraxial Bessel beam. The effect can be explained by the strong interaction of particle's multipoles or by the conservation of momentum in the system “photons-particle.” It is remarkable that the...

  7. Aznar, Hanotin, and May (eds., À la place du roi. Vice-rois, gouverneurs et ambassadeurs dans les monarchies française et espanole (Casa de Velázquez, 2014

    Directory of Open Access Journals (Sweden)

    Lisandra Estevez

    2016-06-01

    Full Text Available The French and Spanish courts were two of the most powerful cultural and political institutions in seventeenth-century Europe.  Both rivals and allies, the French and Spanish crowns were bound by disputes and diplomacy.  This anthology examines the Gallic and Iberian court systems from a comparative approach, filling an important lacuna in early modern political studies and diplomatic history.  It is based on the proceedings of a seminar held at the Casa de Velázquez, Madrid in June 2010. Edited by Daniel Aznar, Guillaume Hanotin and Niels F. May, À la place du roi. Vice-rois, gouverneurs et ambassadeurs dans les monarchies française et espanole (XVIe-XVIIIe siècles unites ten essays by leading scholars of seventeenth-century French and Spanish history.

  8. The Modelling of Axially Translating Flexible Beams

    Science.gov (United States)

    Theodore, R. J.; Arakeri, J. H.; Ghosal, A.

    1996-04-01

    The axially translating flexible beam with a prismatic joint can be modelled by using the Euler-Bernoulli beam equation together with the convective terms. In general, the method of separation of variables cannot be applied to solve this partial differential equation. In this paper, a non-dimensional form of the Euler Bernoulli beam equation is presented, obtained by using the concept of group velocity, and also the conditions under which separation of variables and assumed modes method can be used. The use of clamped-mass boundary conditions leads to a time-dependent frequency equation for the translating flexible beam. A novel method is presented for solving this time dependent frequency equation by using a differential form of the frequency equation. The assume mode/Lagrangian formulation of dynamics is employed to derive closed form equations of motion. It is shown by using Lyapunov's first method that the dynamic responses of flexural modal variables become unstable during retraction of the flexible beam, which the dynamic response during extension of the beam is stable. Numerical simulation results are presented for the uniform axial motion induced transverse vibration for a typical flexible beam.

  9. Overview of the APT high-energy beam transport and beam expanders

    International Nuclear Information System (INIS)

    Shafer, R.E.; Blind, B.; Gray, E.R.

    1997-01-01

    The APT high energy beam transport (HEBT) and beam expanders convey the 1700-MeV, 100-mA cw proton beam from the linac to the tritium target/blanket assembly, or a tuning beam stop. The HEBT includes extensive beam diagnostics, collimators, and beam jitter correction, to monitor and control the 170-MW beam prior to expansion. A zero-degree beamline conveys the beam to the beam stop, and an achromatic bend conveys the beam to the tritium production target. Nonlinear beam expanders make use of higher-order multipole magnets and dithering dipoles to expand the beam to a uniform-density, 16-cm wide by 160-cm high rectangular profile on the tritium-production target. The overall optics design will be reviewed, and beam simulations will be presented

  10. Micro-cantilevers for non-destructive characterization of nanograss uniformity

    DEFF Research Database (Denmark)

    Petersen, Dirch Hjorth; Wang, Fei; Olesen, Mikkel Buster

    2011-01-01

    We demonstrate an application of three-way flexible micro four-point probes for indirect uniformity characterization of surface morphology. The mean sheet conductance of a quasi-planar 3D nanostructured surface is highly dependent on the surface morphology, and thus accurate sheet conductance...... measurements may be useful for process uniformity characterization. The method is applied for characterization of TiW coated nanograss uniformity. Three-way flexible L-shaped cantilever electrodes are used to avoid damage to the fragile surface, and a relative standard deviation on measurement repeatability...... of 0.12 % is obtained with a measurement yield of 97%. Finally, variations in measured sheet conductance are correlated to the surface morphology as characterized by electron microscopy....

  11. A research of possibility for negative muon production by a low energy electron beam accompanying ion beam

    International Nuclear Information System (INIS)

    Uramoto, Joshin.

    1993-12-01

    A low energy electron beam (≤ 2000 eV) is injected perpendicularly to a uniform magnetic field, together with a low energy positive ion beam. On this magnetic mass analysis (using the uniform magnetic field), a peak of secondary electron current to the beam collector (arranging as a mass analyzer of 90deg type), appears at an analyzing magnetic field which corresponds exactly to a relation of negative muon μ - (the mass m=207 m e and the charge q=e, where m e and e are mass and charge of electron). The ion beam is essential for the peak appearance, which is produced by decelerating electrically the electron beam in front of the entrance slit of the mass analyzer, and by introducing a neutral gas into the electron beam region and producing a plasma through the ionization. We consider that a very small amount of negative muons may be produced through local cyclotron motions of the injected beam electrons in the ion beam or by an interaction between the bunched beam electrons and beam ions. (author)

  12. A new non intercepting beam size diagnostics using diffraction radiation from a Slit

    International Nuclear Information System (INIS)

    Castellano, M.

    1996-09-01

    A new non interpreting beam size diagnostic for high charge electron beams is presented. This diagnostics is based on the analysis of the angular distribution of the 'diffracted' transition radiation emitted by the beam when crossing a slit cut in metallic foil. It allows a resolution better then the radiation transverse formation zone. Numerical results based on the parameters of the TTF FEL beam are given as example

  13. Maximizing ROI (return on information)

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, B.

    2000-05-01

    The role and importance of managing information are discussed, underscoring the importance by quoting from the report of the International Data Corporation, according to which Fortune 500 companies lost $ 12 billion in 1999 due to inefficiencies resulting from intellectual re-work, substandard performance , and inability to find knowledge resources. The report predicts that this figure will rise to $ 31.5 billion by 2003. Key impediments to implementing knowledge management systems are identified as : the cost and human resources requirement of deployment; inflexibility of historical systems to adapt to change; and the difficulty of achieving corporate acceptance of inflexible software products that require changes in 'normal' ways of doing business. The author recommends the use of model, document and rule-independent systems with a document centered interface (DCI), employing rapid application development (RAD) and object technologies and visual model development, which eliminate these problems, making it possible for companies to maximize their return on information (ROI), and achieve substantial savings in implementation costs.

  14. Effects of fixture rotation on coating uniformity for high-performance optical filter fabrication

    Science.gov (United States)

    Rubin, Binyamin; George, Jason; Singhal, Riju

    2018-04-01

    Coating uniformity is critical in fabricating high-performance optical filters by various vacuum deposition methods. Simple and planetary rotation systems with shadow masks are used to achieve the required uniformity [J. B. Oliver and D. Talbot, Appl. Optics 45, 13, 3097 (2006); O. Lyngnes, K. Kraus, A. Ode and T. Erguder, in `Method for Designing Coating Thickness Uniformity Shadow Masks for Deposition Systems with a Planetary Fixture', 2014 Technical Conference Proceedings, Optical Coatings, August 13, 2014, DOI: 10.14332/svc14.proc.1817.]. In this work, we discuss the effect of rotation pattern and speed on thickness uniformity in an ion beam sputter deposition system. Numerical modeling is used to determine statistical distribution of random thickness errors in coating layers. The relationship between thickness tolerance and production yield are simulated theoretically and demonstrated experimentally. Production yields for different optical filters produced in an ion beam deposition system with planetary rotation are presented. Single-wavelength and broadband optical monitoring systems were used for endpoint monitoring during filter deposition. Limitations of thickness tolerances that can be achieved in systems with planetary rotation are shown. Paths for improving production yield in an ion beam deposition system are described.

  15. The Clinical Value of Non-Coplanar Photon Beams in Biologically Optimized Intensity Modulated Dose Delivery on Deep-Seated Tumours

    International Nuclear Information System (INIS)

    Ferreira, Brigida C.; Svensson, Roger; Loef, Johan; Brahme, Anders

    2003-01-01

    The aim of the present study is to compare the merits of different radiobiologically optimized treatment techniques using few-field planar and non-coplanar dose delivery on an advanced cancer of the cervix, with rectum and bladder as principal organs at risk. Classically, the rational for using non-coplanar beams is to minimize the overlap of beam entrance and exit regions and to find new beam directions avoiding organs at risk, in order to reduce damage to sensitive normal tissues. Two four-beam configurations have been extensively studied. The first consists of three evenly spaced coplanar beams and a fourth non-coplanar beam. A second tetrahedral-like configuration, with two symmetric non-coplanar beams at the same gantry angle and two coplanar beams, with optimized beam directions, was also tested. The present study shows that when radiobiologically optimized intensity modulated beams are applied to such a geometry, only a marginal increase in the treatment outcome can be achieved by non-coplanar beams compared to the optimal coplanar treatment. The main reason for this result is that the high dose in the beam-overlap regions is already optimally reduced by biologically optimized intensity modulation in the plane. The large number of degrees of freedom already incorporated in the treatment by the use of intensity modulation and radiobiological optimization, leads to the saturation of the benefit acquired by a further increase in the degrees of freedom with non-coplanar beams. In conclusion, the use coplanar of radiobiologically optimized intensity modulation simplifies the dose delivery, reducing the need for non-coplanar beam portals

  16. Versatile generation of optical vector fields and vector beams using a non-interferometric approach.

    Science.gov (United States)

    Tripathi, Santosh; Toussaint, Kimani C

    2012-05-07

    We present a versatile, non-interferometric method for generating vector fields and vector beams which can produce all the states of polarization represented on a higher-order Poincaré sphere. The versatility and non-interferometric nature of this method is expected to enable exploration of various exotic properties of vector fields and vector beams. To illustrate this, we study the propagation properties of some vector fields and find that, in general, propagation alters both their intensity and polarization distribution, and more interestingly, converts some vector fields into vector beams. In the article, we also suggest a modified Jones vector formalism to represent vector fields and vector beams.

  17. A neural algorithm for the non-uniform and adaptive sampling of biomedical data.

    Science.gov (United States)

    Mesin, Luca

    2016-04-01

    Body sensors are finding increasing applications in the self-monitoring for health-care and in the remote surveillance of sensitive people. The physiological data to be sampled can be non-stationary, with bursts of high amplitude and frequency content providing most information. Such data could be sampled efficiently with a non-uniform schedule that increases the sampling rate only during activity bursts. A real time and adaptive algorithm is proposed to select the sampling rate, in order to reduce the number of measured samples, but still recording the main information. The algorithm is based on a neural network which predicts the subsequent samples and their uncertainties, requiring a measurement only when the risk of the prediction is larger than a selectable threshold. Four examples of application to biomedical data are discussed: electromyogram, electrocardiogram, electroencephalogram, and body acceleration. Sampling rates are reduced under the Nyquist limit, still preserving an accurate representation of the data and of their power spectral densities (PSD). For example, sampling at 60% of the Nyquist frequency, the percentage average rectified errors in estimating the signals are on the order of 10% and the PSD is fairly represented, until the highest frequencies. The method outperforms both uniform sampling and compressive sensing applied to the same data. The discussed method allows to go beyond Nyquist limit, still preserving the information content of non-stationary biomedical signals. It could find applications in body sensor networks to lower the number of wireless communications (saving sensor power) and to reduce the occupation of memory. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Non-uniform absorption of terahertz radiation on superconducting hot electron bolometer microbridges

    International Nuclear Information System (INIS)

    Miao, W.; Zhang, W.; Zhong, J. Q.; Shi, S. C.; Delorme, Y.; Lefevre, R.; Feret, A.; Vacelet, T.

    2014-01-01

    We interpret the experimental observation of a frequency-dependence of superconducting hot electron bolometer (HEB) mixers by taking into account the non-uniform absorption of the terahertz radiation on the superconducting HEB microbridge. The radiation absorption is assumed to be proportional to the local surface resistance of the HEB microbridge, which is computed using the Mattis-Bardeen theory. With this assumption the dc and mixing characteristics of a superconducting niobium-nitride (NbN) HEB device have been modeled at frequencies below and above the equilibrium gap frequency of the NbN film

  19. Non-Uniform Laser Surface Texturing of an Un-Tapered Square Pad for Tribological Applications

    Directory of Open Access Journals (Sweden)

    Antonio Ancona

    2017-10-01

    Full Text Available Femtosecond laser surface micro-texturing has emerged as a promising technology to enhance the tribological properties of different kinds of electromechanical devices. In this research paper, we have exploited the intrinsic flexibility and micrometric accuracy of femtosecond laser ablation to realize complex micro-structural modifications on the surface of a laboratory prototype of a steel thrust bearing (un-tapered pad. The Bruggeman Texture Hydrodynamics theory (BTH is employed for the design of the anisotropic and non-uniform texture maximizing the thrust load of the pad prototype. The preliminary experimental results, reported in this work, show that the non-uniform micro-texture largely affects the friction characteristics of the contact. In particular, in agreement with the BTH predictions, the tribo-system shows friction properties that are strongly sensitive to the direction of the sliding speed, as a consequence of the micro-fluid dynamics which are designed to occur only in a specific sliding direction. We suggest that the joint action of virtual prototyping (BTH lubrication theory and ultrafast laser micro-prototyping can lead to unconventional and impressive results in terms of enhanced or tailored contact mechanics properties of the generic lubricated tribopair.

  20. Burnout in a channel with non-uniform circumferential heat flux

    International Nuclear Information System (INIS)

    Lee, D.H.

    1966-03-01

    Burnout experiments are reported for uniform flux and circumferential flux tilt (maximum/average flux about 1.25) with tubes and annuli, all the experiments having uniform axial heating. These show similar results, the burnout power with flux tilt being within 10% of that with uniform flux. For the same mean exit steam quality, the local maximum flux is higher than the predicted burnout value and generally a better prediction is obtained using the average flux. (author)

  1. Observer-based output feedback control of networked control systems with non-uniform sampling and time-varying delay

    Science.gov (United States)

    Meng, Su; Chen, Jie; Sun, Jian

    2017-10-01

    This paper investigates the problem of observer-based output feedback control for networked control systems with non-uniform sampling and time-varying transmission delay. The sampling intervals are assumed to vary within a given interval. The transmission delay belongs to a known interval. A discrete-time model is first established, which contains time-varying delay and norm-bounded uncertainties coming from non-uniform sampling intervals. It is then converted to an interconnection of two subsystems in which the forward channel is delay-free. The scaled small gain theorem is used to derive the stability condition for the closed-loop system. Moreover, the observer-based output feedback controller design method is proposed by utilising a modified cone complementary linearisation algorithm. Finally, numerical examples illustrate the validity and superiority of the proposed method.

  2. Controlling of density uniformity of polyacrylate foams

    International Nuclear Information System (INIS)

    Shan Wenwen; Yuan Baohe; Wang Yanhong; Xu Jiayun; Zhang Lin

    2010-01-01

    The density non-uniformity existing in most low-density foams will affect performance of the foams. The trimethylolpropane trimethacrylate (TMPTA) foam targets were prepared and controlling methods of the foams, density uniformity were explored together with its forming mechanism. It has been found that the UV-light with high intensity can improve the distribution uniformity of the free radicals induced by UV photons in the solvents, thus improve the density uniformity of the foams. In addition, container wall would influence the concentration distribution of the solution, which affects the density uniformity of the foams. Thus, the UV-light with high intensity was chosen together with polytetrafluoroethylene molds instead of glass molds to prepare the foams with the density non-uniformity less than 10%. β-ray detection technology was used to measure the density uniformity of the TMPTA foams with the density in the range of 10 to 100 mg · cm -3 , and the results show that the lower the foam density is, the worse the density uniformity is. (authors)

  3. Beam electron microprobe

    CERN Document Server

    Stoller, D; Muterspaugh, M W; Pollock, R E

    1999-01-01

    A beam profile monitor based on the deflection of a probe electron beam by the electric field of a stored, electron-cooled proton beam is described and first results are presented. Electrons were transported parallel to the proton beam by a uniform longitudinal magnetic field. The probe beam may be slowly scanned across the stored beam to determine its intensity, position, and size. Alternatively, it may be scanned rapidly over a narrow range within the interior of the stored beam for continuous observation of the changing central density during cooling. Examples of a two dimensional charge density profile obtained from a raster scan and of a cooling alignment study illustrate the scope of measurements made possible by this device.

  4. Dose error analysis for a scanned proton beam delivery system

    International Nuclear Information System (INIS)

    Coutrakon, G; Wang, N; Miller, D W; Yang, Y

    2010-01-01

    All particle beam scanning systems are subject to dose delivery errors due to errors in position, energy and intensity of the delivered beam. In addition, finite scan speeds, beam spill non-uniformities, and delays in detector, detector electronics and magnet responses will all contribute errors in delivery. In this paper, we present dose errors for an 8 x 10 x 8 cm 3 target of uniform water equivalent density with 8 cm spread out Bragg peak and a prescribed dose of 2 Gy. Lower doses are also analyzed and presented later in the paper. Beam energy errors and errors due to limitations of scanning system hardware have been included in the analysis. By using Gaussian shaped pencil beams derived from measurements in the research room of the James M Slater Proton Treatment and Research Center at Loma Linda, CA and executing treatment simulations multiple times, statistical dose errors have been calculated in each 2.5 mm cubic voxel in the target. These errors were calculated by delivering multiple treatments to the same volume and calculating the rms variation in delivered dose at each voxel in the target. The variations in dose were the result of random beam delivery errors such as proton energy, spot position and intensity fluctuations. The results show that with reasonable assumptions of random beam delivery errors, the spot scanning technique yielded an rms dose error in each voxel less than 2% or 3% of the 2 Gy prescribed dose. These calculated errors are within acceptable clinical limits for radiation therapy.

  5. LED Uniform Illumination Using Double Linear Fresnel Lenses for Energy Saving

    Directory of Open Access Journals (Sweden)

    Ngoc Hai Vu

    2017-12-01

    Full Text Available We present a linear Fresnel lens design for light-emitting diode (LED uniform illumination applications. The LED source is an array of LEDs. An array of collimating lens is applied to collimate output from the LED array. Two linear Fresnel lenses are used to redistribute the collimated beam along two dimensions in the illumination area. Collimating lens and linear Fresnel lens surfaces are calculated by geometrical optics and nonimaging optics. The collimated beam output from the collimating lens array is divided into many fragments. Each fragment is refracted by a segment of Fresnel lens and distributed over the illumination area, so that the total beam can be distributed to the illumination target uniformly. The simulation results show that this design has a compact structure, high optical efficiency of 82% and good uniformity of 76.9%. Some consideration of the energy savings and optical performance are discussed by comparison with other typical light sources. The results show that our proposed LED lighting system can reduce energy consumption five-times in comparison to using a conventional fluorescent lamp. Our research is a strong candidate for low cost, energy savings for indoor and outdoor lighting applications.

  6. Ion beam enhancement in magnetically insulated ion diodes for high-intensity pulsed ion beam generation in non-relativistic mode

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, X. P. [Key Laboratory of Materials Modification by Laser, Ion, and Electron Beams, Ministry of Education, Dalian University of Technology, Dalian 116024 (China); Surface Engineering Laboratory, School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024 (China); Zhang, Z. C.; Lei, M. K., E-mail: surfeng@dlut.edu.cn [Surface Engineering Laboratory, School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024 (China); Pushkarev, A. I. [Surface Engineering Laboratory, School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024 (China); Laboratory of Beam and Plasma Technology, High Technologies Physics Institute, Tomsk Polytechnic University, 30, Lenin Ave, 634050 Tomsk (Russian Federation)

    2016-01-15

    High-intensity pulsed ion beam (HIPIB) with ion current density above Child-Langmuir limit is achieved by extracting ion beam from anode plasma of ion diodes with suppressing electron flow under magnetic field insulation. It was theoretically estimated that with increasing the magnetic field, a maximal value of ion current density may reach nearly 3 times that of Child-Langmuir limit in a non-relativistic mode and close to 6 times in a highly relativistic mode. In this study, the behavior of ion beam enhancement by magnetic insulation is systematically investigated in three types of magnetically insulated ion diodes (MIDs) with passive anode, taking into account the anode plasma generation process on the anode surface. A maximal enhancement factor higher than 6 over the Child-Langmuir limit can be obtained in the non-relativistic mode with accelerating voltage of 200–300 kV. The MIDs differ in two anode plasma formation mechanisms, i.e., surface flashover of a dielectric coating on the anode and explosive emission of electrons from the anode, as well as in two insulation modes of external-magnetic field and self-magnetic field with either non-closed or closed drift of electrons in the anode-cathode (A-K) gap, respectively. Combined with ion current density measurement, energy density characterization is employed to resolve the spatial distribution of energy density before focusing for exploring the ion beam generation process. Consistent results are obtained on three types of MIDs concerning control of neutralizing electron flows for the space charge of ions where the high ion beam enhancement is determined by effective electron neutralization in the A-K gap, while the HIPIB composition of different ion species downstream from the diode may be considerably affected by the ion beam neutralization during propagation.

  7. Optical forces in a non-diffracting vortex beam

    Czech Academy of Sciences Publication Activity Database

    Šiler, Martin; Zemánek, Pavel

    2013-01-01

    Roč. 126, September (2013), s. 78-83 ISSN 0022-4073 R&D Projects: GA ČR GPP205/12/P868; GA MŠk LH12018; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : dielectric microparticle * non-diffracting vortex beam Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.288, year: 2013

  8. Transverse velocity modulator and generator schemes based on non-collinear radiation and electron beams

    CERN Document Server

    Varfolomeev, A A

    2000-01-01

    New non-collinear schemes are suggested for transverse velocity modulation of electron beams and for the generation of coherent spontaneous radiation by these transversely modulated beams. It is shown that due to the non-collinearity some orders of magnitude enhancement can be achieved for the coherent spontaneous radiation (CSR) power at both the fundamental and harmonic frequencies.

  9. Bounds of thermal stability of infinite cylindrical structures with non-uniform internal heat generation

    International Nuclear Information System (INIS)

    Gadalla, M.A.

    1992-01-01

    This paper presents an overview analyses of the thermal instability or thermal viability of infinite cylindrical structures with non-linear and non-uniform internal heat generation. The structure may be subjected to different and combined boundary conditions. An analytical solution is obtained for the generalized problem in spite of the non-linearity and the non-homogeneity of the source term. Four case studies with different boundary conditions are presented. The analyses show that the critical parameter for thermal stability may be though of as an altitude of surface below which the cylindrical structure will be thermally stable and performance worthy. The results also show that the bounds of thermal stability of a cylindrical structure system (solid or hollow) is eminently determined by the boundary conditions to which the system is subjected and can significantly alter the life-span of the structure

  10. Non-uniform temperature field measurement and simulation of a radio telescope’s main reflector under solar radiation

    International Nuclear Information System (INIS)

    Chen, Deshen; Qian, Hongliang; Wang, Huajie; Zhang, Gang; Fan, Feng; Shen, Shizhao

    2017-01-01

    Highlights: • Solar non-uniform temperature field test of a telescope’s reflector is conducted initially. • Time-varying distribution regularities are analyzed contrastively. • Simulation methods are proposed involving environmental factors and self-shadowing. • Refined discrimination method for the shadow distribution is put forward. • Validity of simulation methods is evaluated with the experimental data. - Abstract: To improve the ability of deep-space exploration, many astronomers around the world are actively engaged in the construction of large-aperture and high-precision radio telescopes. The temperature effect is one of three main factors affecting the reflector accuracy of radio telescopes. To study the daily non-uniform temperature field of the main reflector, experimental studies are first carried out with a 3-m-aperture radio telescope model. According to the test results for 16 working conditions, the distribution rule and time-varying regularity of the daily temperature field are summarized initially. Next, theoretical methods for the temperature field of the main reflector are studied considering multiple environmental parameters and self-shadows. Finally, the validity of the theoretical methods is evaluated with test results. The experimental study demonstrates that the non-uniform temperature distribution of the main reflector truly exists and should not be overlooked, and that the theoretical methods for the reflector temperature field proposed in this paper are effective. The research methods and conclusions can provide valuable references for thermal design, monitoring and control of similar high-precision radio telescopes.

  11. Tumor and normal tissue responses to fractioned non-uniform dose delivery

    Energy Technology Data Exchange (ETDEWEB)

    Kaellman, P; Aegren, A; Brahme, A [Karolinska Inst., Stockholm (Sweden). Dept. of Radiation Physics

    1996-08-01

    The volume dependence of the radiation response of a tumor is straight forward to quantify because it depends primarily on the eradication of all its clonogenic cells. A tumor therefore has a parallel organization as any surviving clonogen in principle can repopulate the tumor. The difficulty with the response of the tumor is instead to know the density and sensitivity distribution of the most resistant clonogenic cells. The increase in the 50% tumor control dose and the decrease in the maximum normalized slope of the dose response relation, {gamma}, in presence of small compartments of resistant tumor cells have therefore been quantified to describe their influence on the dose response relation. Injury to normal tissue is a much more complex and gradual process. It depends on earlier effects induced long before depletion of the differentiated and clonogenic cells that in addition may have a complex structural and functional organization. The volume dependence of the dose response relation of normal tissues is therefore described here by the relative seriality, s, of the infrastructure of the organ. The model can also be generalized to describe the response of heterogeneous tissues to non uniform dose distributions. The new model is compared with clinical and experimental data on normal tissue response, and shows good agreement both with regard to the shape of dose response relation and the volume dependence of the isoeffect dose. The response of tumors and normal tissues are quantified for arbitrary dose fractionations using the linear quadratic cell survival parameters {alpha} and {beta}. The parameters of the dose response relation are derived both for a constant dose per fraction and a constant number of dose fractions, thus in the latter case accounting also for non uniform dose delivery. (author). 26 refs, 4 figs.

  12. Interference of Locally Forced Internal Waves in Non-Uniform Stratifications

    Science.gov (United States)

    Supekar, Rohit; Peacock, Thomas

    2017-11-01

    Several studies have investigated the effect of constructive or destructive interference on the transmission of internal waves propagating through non-uniform stratifications. Such studies have been performed for internal waves that are spatiotemporally harmonic. To understand the effect of localization, we perform a theoretical and experimental study of the transmission of two-dimensional internal waves that are generated by a spatiotemporally localized boundary forcing. This is done by considering an idealized problem and applying a weakly viscous semi-analytic linear model. Parametric studies using this model show that localization leads to the disappearance of transmission peaks and troughs that would otherwise be present for a harmonic forcing. Laboratory experiments that we perform provide a clear indication of this physical effect. Based on the group velocity and angle of propagation of the internal waves, a practical criteria that assesses when the transmission peaks or troughs are evident, is obtained. It is found that there is a significant difference in the predicted energy transfer due to a harmonic and non-harmonic forcing which has direct implications to various physical forcings such as a storm over the ocean.

  13. Dynamic modelling and control of a rotating Euler-Bernoulli beam

    Science.gov (United States)

    Yang, J. B.; Jiang, L. J.; Chen, D. CH.

    2004-07-01

    Flexible motion of a uniform Euler-Bernoulli beam attached to a rotating rigid hub is investigated. Fully coupled non-linear integro-differential equations, describing axial, transverse and rotational motions of the beam, are derived by using the extended Hamilton's principle. The centrifugal stiffening effect is included in the derivation. A finite-dimensional model, including couplings of axial and transverse vibrations, and of elastic deformations and rigid motions, is obtained by the finite element method. By neglecting the axial motion, a simplified modelling, suitable for studying the transverse vibration and control of a beam with large angle and high-speed rotation, is presented. And suppressions of transverse vibrations of a rotating beam are simulated with the model by combining positive position feedback and momentum exchange feedback control laws. It is indicated that an improved performance for vibration control can be achieved with the method.

  14. Capacitated Vehicle Routing with Non-Uniform Speeds

    DEFF Research Database (Denmark)

    Gørtz, Inge Li; Molinaro, Marco; Nagarajan, Viswanath

    2011-01-01

    -uniform speeds (that we call Heterogenous CVRP), and present a constant-factor approximation algorithm. The technical heart of our result lies in achieving a constant approximation to the following TSP variant (called Heterogenous TSP). Given a metric denoting distances between vertices, a depot r containing k...

  15. Broadband non-polarizing beam splitter based on guided mode resonance effect

    Science.gov (United States)

    Ma, Jian-Yong; Xu, Cheng; Qiang, Ying-Huai; Zhu, Ya-Bo

    2011-10-01

    A broadband non-polarizing beam splitter (NPBS) operating in the telecommunication C+L band is designed by using the guided mode resonance effect of periodic silicon-on-insulator (SOI) elements. It is shown that this double layer SOI structure can provide ~50/50 beam ratio with the maximum divergences between reflection and transmission being less than 8% over the spectrum of 1.4 μm~1.7 μm and 1% in the telecommunication band for both TE and TM polarizations. The physical basis of this broadband non-polarizing property is on the simultaneous excitation of the TE and TM strong modulation waveguide modes near the designed spectrum band. Meanwhile, the electric field distributions for both TE and TM polarizations verify the resonant origin of spectrum in the periodic SOI structure. Furthermore, it is demonstrated with our calculations that the beam splitter proposed here is tolerant to the deviations of incident angle and structure parameters, which make it very easy to be fabricated with current IC technology.

  16. Data from the Roi Removal Project, West Hawaii, 2010-2011 (NODC Accession 0082197

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — In situ observations of the introduced predatory grouper roi (Cephalopholis argus) were taken within the coral reef ecosystem of Puako, northwest side of the Island...

  17. Uniform and Non-Uniform Optimum Scalar Quantizers Performances: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Fendy Santoso

    2008-05-01

    Full Text Available The aim of this research is to investigate source coding, the representation of information source output by finite R bits/symbol. The performance of optimum quantisers subject to an entropy constraint has been studied. The definitive work in this area is best summarised by Shannon’s source coding theorem, that is, a source with entropy H can be encoded with arbitrarily small error probability at any rate R (bits/source output as long as R>H. Conversely, If R the error probability will be driven away from zero, independent of the complexity of the encoder and the decoder employed. In this context, the main objective of engineers is however to design the optimum code. Unfortunately, the rate-distortion theorem does not provide the recipe for such a design. The theorem does, however, provide the theoretical limit so that we know how close we are to the optimum. The full understanding of the theorem also helps in setting the direction to achieve such an optimum. In this research, we have investigated the performances of two practical scalar quantisers, i.e., a Lloyd-Max quantiser and the uniformly defined one and also a well-known entropy coding scheme, i.e., Huffman coding against their theoretically attainable optimum performance due to Shannon’s limit R. It has been shown that our uniformly defined quantiser could demonstrate superior performance. The performance improvements, in fact, are more noticeable at higher bit rates.

  18. Shape and fission instabilities of ferrofluids in non-uniform magnetic fields

    Science.gov (United States)

    Vieu, Thibault; Walter, Clément

    2018-04-01

    We study static distributions of ferrofluid submitted to non-uniform magnetic fields. We show how the normal-field instability is modified in the presence of a weak magnetic field gradient. Then we consider a ferrofluid droplet and show how the gradient affects its shape. A rich phase transitions phenomenology is found. We also investigate the creation of droplets by successive splits when a magnet is vertically approached from below and derive theoretical expressions which are solved numerically to obtain the number of droplets and their aspect ratio as function of the field configuration. A quantitative comparison is performed with previous experimental results, as well as with our own experiments, and yields good agreement with the theoretical modeling.

  19. Laser investigation of the non-uniformity of fluorescent species in dental enamel

    Science.gov (United States)

    Tran, Stephanie U.; Ridge, Jeremy S.; Nelson, Leonard Y.; Seibel, Eric J.

    In the present study, artificial type I and type II erosions were created on dental specimen using acetic acid and EDTA respectively. Specimens were prepared by etching extracted teeth samples in acid to varying degrees, after which the absolute fluorescence intensity ratio of the etched enamel relative to sound enamel was recorded for each specimen using 405 and 532 nm laser excitation. Results showed differences in the fluorescence ratio of etched to sound enamel for type I and II erosions. These findings suggest a non-uniform distribution of fluorescent species in the interprismatic region as compared to the prismatic region.

  20. Thermal sensation and comfort models for non-uniform and transient environments: Part III: whole-body sensation and comfort

    OpenAIRE

    Zhang, Hui; Arens, Edward; Huizenga, Charlie; Han, Taeyoung

    2009-01-01

    A three-part series presents the development of models for predicting the local thermal sensation (Part I) and local thermal comfort (Part II) of different parts of the human body, and also the whole-body sensation and comfort (Part III) that result from combinations of local sensation and comfort. The models apply to sedentary activities in a range of environments: uniform and non-uniform, stable and transient. They are based on diverse findings from the literature and from body-part-specifi...

  1. Natural Frequencies and Mode Shapes of a Nonlinear, Uniform Cantilevered Beam

    National Research Council Canada - National Science Library

    Marquez-Chisolm, Daniel J

    2006-01-01

    A series of experiments in 1975, referred to as the Princeton Beam Experiments, were performed to measure natural frequencies and create a nonlinear elastic deformation model to improve helicopter main beam designs...

  2. Natural Frequencies and Mode Shapes of a Nonlinear, Uniform Cantilevered Beam

    National Research Council Canada - National Science Library

    Marquez-Chisolm, Daniel J

    2006-01-01

    .... These experiments used a homogeneous 7075 aluminum beam and have been referenced as a baseline for the past thirty years to validate computer models and theories in an effort to build beams capable...

  3. Electron, ion and atomic beams interaction with solid high-molecular dielectrics

    Energy Technology Data Exchange (ETDEWEB)

    Milyavskij, V V; Skvortsov, V A [Russian Academy of Sciences, Moscow (Russian Federation). High Energy Density Research Center

    1997-12-31

    A mathematical model was constructed and numerical investigation performed of the interaction between intense electron, ion and atomic beams and solid high-molecular dielectrics under various boundary conditions. The model is based on equations of the mechanics of continuum, electrodynamics and kinetics, describing the accumulation and relaxation of space charge and shock-wave processes, as well as the evolution of electric field in the sample. A semi-empirical procedure is proposed for the calculation of energy deposition by electron beam in a target in the presence of a non-uniform electric field. (author). 4 figs., 2 refs.

  4. Efficient random access high resolution region-of-interest (ROI) image retrieval using backward coding of wavelet trees (BCWT)

    Science.gov (United States)

    Corona, Enrique; Nutter, Brian; Mitra, Sunanda; Guo, Jiangling; Karp, Tanja

    2008-03-01

    Efficient retrieval of high quality Regions-Of-Interest (ROI) from high resolution medical images is essential for reliable interpretation and accurate diagnosis. Random access to high quality ROI from codestreams is becoming an essential feature in many still image compression applications, particularly in viewing diseased areas from large medical images. This feature is easier to implement in block based codecs because of the inherent spatial independency of the code blocks. This independency implies that the decoding order of the blocks is unimportant as long as the position for each is properly identified. In contrast, wavelet-tree based codecs naturally use some interdependency that exploits the decaying spectrum model of the wavelet coefficients. Thus one must keep track of the decoding order from level to level with such codecs. We have developed an innovative multi-rate image subband coding scheme using "Backward Coding of Wavelet Trees (BCWT)" which is fast, memory efficient, and resolution scalable. It offers far less complexity than many other existing codecs including both, wavelet-tree, and block based algorithms. The ROI feature in BCWT is implemented through a transcoder stage that generates a new BCWT codestream containing only the information associated with the user-defined ROI. This paper presents an efficient technique that locates a particular ROI within the BCWT coded domain, and decodes it back to the spatial domain. This technique allows better access and proper identification of pathologies in high resolution images since only a small fraction of the codestream is required to be transmitted and analyzed.

  5. Flat-topped beam transmittance in anisotropic non-Kolmogorov turbulent marine atmosphere

    Science.gov (United States)

    Ata, Yalçın; Baykal, Yahya

    2017-10-01

    Turbulence affects optical propagation, and, as a result, the intensity is attenuated along the path of propagation. The attenuation becomes significant when the turbulence becomes stronger. Transmittance is a measure indicating how much power is collected at the receiver after the optical wave propagates in the turbulent medium. The on-axis transmittance is formulated when a flat-topped optical beam propagates in a marine atmosphere experiencing anisotropic non-Kolmogorov turbulence. Variations in the transmittance are evaluated versus the beam source size, beam number, link distance, power law exponent, anisotropy factor, and structure constant. It is found that larger beam source sizes and beam numbers yield higher transmittance values; however, as the link distance, power law exponent, anisotropy factor, or structure constant increase, transmittance values are lowered. Our results will help in the performance evaluations of optical wireless communication and optical imaging systems operating in a marine atmosphere.

  6. Development of neutral beam source using electron beam excited plasma

    International Nuclear Information System (INIS)

    Hara, Yasuhiro; Hamagaki, Manabu; Mise, Takaya; Hara, Tamio

    2011-01-01

    A low-energy neutral beam (NB) source, which consists of an electron-beam-excited plasma (EBEP) source and two carbon electrodes, has been developed for damageless etching of ultra-large-scale integrated (ULSI) devices. It has been confirmed that the Ar ion beam energy was controlled by the acceleration voltage and the beam profile had good uniformity over the diameter of 80 mm. Dry etching of a Si wafer at the floating potential has been carried out by Ar NB. Si sputtering yield by an Ar NB clearly depends on the acceleration voltage. This result shows that the NB has been generated through the charge exchange reaction from the ion beam in the process chamber. (author)

  7. SU-F-J-211: Scatter Correction for Clinical Cone-Beam CT System Using An Optimized Stationary Beam Blocker with a Single Scan

    International Nuclear Information System (INIS)

    Liang, X; Zhang, Z; Xie, Y; Gong, S; Niu, T; Zhou, Q

    2016-01-01

    Purpose: X-ray scatter photons result in significant image quality degradation of cone-beam CT (CBCT). Measurement based algorithms using beam blocker directly acquire the scatter samples and achieve significant improvement on the quality of CBCT image. Within existing algorithms, single-scan and stationary beam blocker proposed previously is promising due to its simplicity and practicability. Although demonstrated effectively on tabletop system, the blocker fails to estimate the scatter distribution on clinical CBCT system mainly due to the gantry wobble. In addition, the uniform distributed blocker strips in our previous design results in primary data loss in the CBCT system and leads to the image artifacts due to data insufficiency. Methods: We investigate the motion behavior of the beam blocker in each projection and design an optimized non-uniform blocker strip distribution which accounts for the data insufficiency issue. An accurate scatter estimation is then achieved from the wobble modeling. Blocker wobble curve is estimated using threshold-based segmentation algorithms in each projection. In the blocker design optimization, the quality of final image is quantified using the number of the primary data loss voxels and the mesh adaptive direct search algorithm is applied to minimize the objective function. Scatter-corrected CT images are obtained using the optimized blocker. Results: The proposed method is evaluated using Catphan@504 phantom and a head patient. On the Catphan©504, our approach reduces the average CT number error from 115 Hounsfield unit (HU) to 11 HU in the selected regions of interest, and improves the image contrast by a factor of 1.45 in the high-contrast regions. On the head patient, the CT number error is reduced from 97 HU to 6 HU in the soft tissue region and image spatial non-uniformity is decreased from 27% to 5% after correction. Conclusion: The proposed optimized blocker design is practical and attractive for CBCT guided radiation

  8. SU-F-J-211: Scatter Correction for Clinical Cone-Beam CT System Using An Optimized Stationary Beam Blocker with a Single Scan

    Energy Technology Data Exchange (ETDEWEB)

    Liang, X; Zhang, Z; Xie, Y [Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, GuangDong (China); Gong, S; Niu, T [Department of Radiation Oncology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang (China); Institute of Translational Medicine, Zhejiang University, Hangzhou, Zhejiang (China); Zhou, Q [Department of Radiation Oncology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang (China)

    2016-06-15

    Purpose: X-ray scatter photons result in significant image quality degradation of cone-beam CT (CBCT). Measurement based algorithms using beam blocker directly acquire the scatter samples and achieve significant improvement on the quality of CBCT image. Within existing algorithms, single-scan and stationary beam blocker proposed previously is promising due to its simplicity and practicability. Although demonstrated effectively on tabletop system, the blocker fails to estimate the scatter distribution on clinical CBCT system mainly due to the gantry wobble. In addition, the uniform distributed blocker strips in our previous design results in primary data loss in the CBCT system and leads to the image artifacts due to data insufficiency. Methods: We investigate the motion behavior of the beam blocker in each projection and design an optimized non-uniform blocker strip distribution which accounts for the data insufficiency issue. An accurate scatter estimation is then achieved from the wobble modeling. Blocker wobble curve is estimated using threshold-based segmentation algorithms in each projection. In the blocker design optimization, the quality of final image is quantified using the number of the primary data loss voxels and the mesh adaptive direct search algorithm is applied to minimize the objective function. Scatter-corrected CT images are obtained using the optimized blocker. Results: The proposed method is evaluated using Catphan@504 phantom and a head patient. On the Catphan©504, our approach reduces the average CT number error from 115 Hounsfield unit (HU) to 11 HU in the selected regions of interest, and improves the image contrast by a factor of 1.45 in the high-contrast regions. On the head patient, the CT number error is reduced from 97 HU to 6 HU in the soft tissue region and image spatial non-uniformity is decreased from 27% to 5% after correction. Conclusion: The proposed optimized blocker design is practical and attractive for CBCT guided radiation

  9. Arc-based smoothing of ion beam intensity on targets

    International Nuclear Information System (INIS)

    Friedman, Alex

    2012-01-01

    By manipulating a set of ion beams upstream of a target, it is possible to arrange for a smoother deposition pattern, so as to achieve more uniform illumination of the target. A uniform energy deposition pattern is important for applications including ion-beam-driven high energy density physics and heavy-ion beam-driven inertial fusion energy (“heavy-ion fusion”). Here, we consider an approach to such smoothing that is based on rapidly “wobbling” each of the beams back and forth along a short arc-shaped path, via oscillating fields applied upstream of the final pulse compression. In this technique, uniformity is achieved in the time-averaged sense; this is sufficient provided the beam oscillation timescale is short relative to the hydrodynamic timescale of the target implosion. This work builds on two earlier concepts: elliptical beams applied to a distributed-radiator target [D. A. Callahan and M. Tabak, Phys. Plasmas 7, 2083 (2000)] and beams that are wobbled so as to trace a number of full rotations around a circular or elliptical path [R. C. Arnold et al., Nucl. Instrum. Methods 199, 557 (1982)]. Here, we describe the arc-based smoothing approach and compare it to results obtainable using an elliptical-beam prescription. In particular, we assess the potential of these approaches for minimization of azimuthal asymmetry, for the case of a ring of beams arranged on a cone. It is found that, for small numbers of beams on the ring, the arc-based smoothing approach offers superior uniformity. In contrast with the full-rotation approach, arc-based smoothing remains usable when the geometry precludes wobbling the beams around a full circle, e.g., for the X-target [E. Henestroza, B. G. Logan, and L. J. Perkins, Phys. Plasmas 18, 032702 (2011)] and some classes of distributed-radiator targets.

  10. Non-uniform Mutation Rates for Problems with Unknown Solution Lengths

    DEFF Research Database (Denmark)

    Cathabard, Stephan; Lehre, Per Kristian; Yao, Xin

    2011-01-01

    Many practical optimisation problems allow candidate solu- tions of varying lengths, and where the length of the opti- mal solution is thereby a priori unknown. We suggest that non-uniform mutation rates can be beneficial when solving such problems. In particular, we consider a mutation oper- ator...... that flips each bit with a probability that is inversely proportional to the bit position, rather than the bitstring length. The runtime of the (1+1) EA using this mutation operator is analysed rigorously on standard example func- tions. Furthermore, the behaviour of the new mutation op- erator...... distribution, and show that the new operator can yield exponentially faster runtimes for some parameters of this distribution. The experimental results show that the new mutation operator leads to dramatically shorter runtimes on a class of instances of the software engi- neering problem that is conjectured...

  11. Period doubling on a non-neutral magnetized electron beam

    International Nuclear Information System (INIS)

    Boswell, R.W.

    1984-01-01

    Low frequency oscillations on a non-neutral magnetized electron beam of very low density are investigated. A perturbation analysis of the slow mode of the rigid rotator equilibrium is developed to illustrate the nature of large amplitude fundamental mode oscillations. The results of this theoretical analysis show two important characteristics: firstly, as the perturbation amplitude is increasedthe waveform ceases to be purely sinusoidal and shows period doubling. Secondly, above a certain threshold, all harmonics of the wave grow and the wave breaks. The results of the former are compared with a simple electron beam experiment and are found to be in good qualitative agreement

  12. Thermoelastic analysis of non-uniform pressurized functionally graded cylinder with variable thickness using first order shear deformation theory(FSDT) and perturbation method

    Science.gov (United States)

    Khoshgoftar, M. J.; Mirzaali, M. J.; Rahimi, G. H.

    2015-11-01

    Recently application of functionally graded materials(FGMs) have attracted a great deal of interest. These materials are composed of various materials with different micro-structures which can vary spatially in FGMs. Such composites with varying thickness and non-uniform pressure can be used in the aerospace engineering. Therefore, analysis of such composite is of high importance in engineering problems. Thermoelastic analysis of functionally graded cylinder with variable thickness under non-uniform pressure is considered. First order shear deformation theory and total potential energy approach is applied to obtain the governing equations of non-homogeneous cylinder. Considering the inner and outer solutions, perturbation series are applied to solve the governing equations. Outer solution for out of boundaries and more sensitive variable in inner solution at the boundaries are considered. Combining of inner and outer solution for near and far points from boundaries leads to high accurate displacement field distribution. The main aim of this paper is to show the capability of matched asymptotic solution for different non-homogeneous cylinders with different shapes and different non-uniform pressures. The results can be used to design the optimum thickness of the cylinder and also some properties such as high temperature residence by applying non-homogeneous material.

  13. A modified KdV equation with self-consistent sources in non-uniform media and soliton dynamics

    International Nuclear Information System (INIS)

    Zhang Dajun; Bi Jinbo; Hao Honghai

    2006-01-01

    Two non-isospectral modified KdV equations with self-consistent sources are derived, which correspond to the time-dependent spectral parameter λ satisfying λ t = λ and λ t = λ 3 , respectively. Gauge transformation between the first non-isospectral equation (corresponding to λ t = λ) and its isospectral counterpart is given, from which exact solutions and conservation laws for the non-isospectral one are easily listed. Besides, solutions to the two non-isospectral modified KdV equations with self-consistent sources are derived by means of the Hirota method and the Wronskian technique, respectively. Non-isospectral dynamics and source effects, including one-soliton characteristics in non-uniform media, two-solitons scattering and special behaviours related to sources (for example, the 'ghost' solitons in the degenerate two-soliton case), are investigated analytically

  14. Clinical proton dosimetry. Part 1: Beam production, beam delivery and measurement of absorbed dose

    International Nuclear Information System (INIS)

    1998-01-01

    The development of accurate and uniform standards for radiation treatment dosimetry has been a continuing effort since the earliest days of radiotherapy. This ICRU Report is intended to promote uniformity of standards that will provide a basis for world-wide comparison of clinical results and allow the development of meaningful clinical trials. This Report describes current practice in proton therapy and recommends standards for the dosimetry of proton treatments. Established proton treatment facilities might use this Report as a source of information for the maintenance of accurate standards. New facilities may build their procedures from recommendations found in this Report and planners of new facilities may examine alternatives within current practice for the production and monitoring of treatment beams. This Report includes a description of the interaction of protons with matter, various methods of beam production, the characteristics of proton beams in clinical use, current methods for beam monitoring and specific recommendations for dose calibration

  15. Could the peristaltic transition zone be caused by non-uniform esophageal muscle fiber architecture? A simulation study.

    Science.gov (United States)

    Kou, W; Pandolfino, J E; Kahrilas, P J; Patankar, N A

    2017-06-01

    Based on a fully coupled computational model of esophageal transport, we analyzed how varied esophageal muscle fiber architecture and/or dual contraction waves (CWs) affect bolus transport. Specifically, we studied the luminal pressure profile in those cases to better understand possible origins of the peristaltic transition zone. Two groups of studies were conducted using a computational model. The first studied esophageal transport with circumferential-longitudinal fiber architecture, helical fiber architecture and various combinations of the two. In the second group, cases with dual CWs and varied muscle fiber architecture were simulated. Overall transport characteristics were examined and the space-time profiles of luminal pressure were plotted and compared. Helical muscle fiber architecture featured reduced circumferential wall stress, greater esophageal distensibility, and greater axial shortening. Non-uniform fiber architecture featured a peristaltic pressure trough between two high-pressure segments. The distal pressure segment showed greater amplitude than the proximal segment, consistent with experimental data. Dual CWs also featured a pressure trough between two high-pressure segments. However, the minimum pressure in the region of overlap was much lower, and the amplitudes of the two high-pressure segments were similar. The efficacy of esophageal transport is greatly affected by muscle fiber architecture. The peristaltic transition zone may be attributable to non-uniform architecture of muscle fibers along the length of the esophagus and/or dual CWs. The difference in amplitude between the proximal and distal pressure segments may be attributable to non-uniform muscle fiber architecture. © 2017 John Wiley & Sons Ltd.

  16. Broadband non-polarizing terahertz beam splitters with variable split ratio

    KAUST Repository

    Wei, Minggui

    2017-08-15

    Seeking effective terahertz functional devices has always aroused extensive attention. Of particular interest is the terahertz beam splitter. Here, we have proposed, designed, manufactured, and tested a broadband non-polarizing terahertz beam splitter with a variable split ratio based on an all-dielectric metasurface. The metasurface was created by patterning a dielectric surface of the N-step phase gradient and etching to a few hundred micrometers. The conversion efficiency as high as 81% under the normal incidence at 0.7 THz was achieved. Meanwhile, such a splitter works well over a broad frequency range. The split ratio of the proposed design can be continuously tuned by simply shifting the metasurface, and the angle of emergences can also be easily adjusted by choosing the step of phase gradients. The proposed design is non-polarizing, and its performance is kept under different polarizations.

  17. Broadband non-polarizing terahertz beam splitters with variable split ratio

    Science.gov (United States)

    Wei, Minggui; Xu, Quan; Wang, Qiu; Zhang, Xueqian; Li, Yanfeng; Gu, Jianqiang; Tian, Zhen; Zhang, Xixiang; Han, Jiaguang; Zhang, Weili

    2017-08-01

    Seeking effective terahertz functional devices has always aroused extensive attention. Of particular interest is the terahertz beam splitter. Here, we have proposed, designed, manufactured, and tested a broadband non-polarizing terahertz beam splitter with a variable split ratio based on an all-dielectric metasurface. The metasurface was created by patterning a dielectric surface of the N-step phase gradient and etching to a few hundred micrometers. The conversion efficiency as high as 81% under the normal incidence at 0.7 THz was achieved. Meanwhile, such a splitter works well over a broad frequency range. The split ratio of the proposed design can be continuously tuned by simply shifting the metasurface, and the angle of emergences can also be easily adjusted by choosing the step of phase gradients. The proposed design is non-polarizing, and its performance is kept under different polarizations.

  18. Broadband non-polarizing terahertz beam splitters with variable split ratio

    KAUST Repository

    Wei, Minggui; Xu, Quan; Wang, Qiu; Zhang, Xueqian; Li, Yanfeng; Gu, Jianqiang; Tian, Zhen; Zhang, Xixiang; Han, Jiaguang; Zhang, Weili

    2017-01-01

    Seeking effective terahertz functional devices has always aroused extensive attention. Of particular interest is the terahertz beam splitter. Here, we have proposed, designed, manufactured, and tested a broadband non-polarizing terahertz beam splitter with a variable split ratio based on an all-dielectric metasurface. The metasurface was created by patterning a dielectric surface of the N-step phase gradient and etching to a few hundred micrometers. The conversion efficiency as high as 81% under the normal incidence at 0.7 THz was achieved. Meanwhile, such a splitter works well over a broad frequency range. The split ratio of the proposed design can be continuously tuned by simply shifting the metasurface, and the angle of emergences can also be easily adjusted by choosing the step of phase gradients. The proposed design is non-polarizing, and its performance is kept under different polarizations.

  19. Developing semi-analytical solution for multiple-zone transient storage model with spatially non-uniform storage

    Science.gov (United States)

    Deng, Baoqing; Si, Yinbing; Wang, Jia

    2017-12-01

    Transient storages may vary along the stream due to stream hydraulic conditions and the characteristics of storage. Analytical solutions of transient storage models in literature didn't cover the spatially non-uniform storage. A novel integral transform strategy is presented that simultaneously performs integral transforms to the concentrations in the stream and in storage zones by using the single set of eigenfunctions derived from the advection-diffusion equation of the stream. The semi-analytical solution of the multiple-zone transient storage model with the spatially non-uniform storage is obtained by applying the generalized integral transform technique to all partial differential equations in the multiple-zone transient storage model. The derived semi-analytical solution is validated against the field data in literature. Good agreement between the computed data and the field data is obtained. Some illustrative examples are formulated to demonstrate the applications of the present solution. It is shown that solute transport can be greatly affected by the variation of mass exchange coefficient and the ratio of cross-sectional areas. When the ratio of cross-sectional areas is big or the mass exchange coefficient is small, more reaches are recommended to calibrate the parameter.

  20. Acceleration of Solar Energetic Particles at a Fast Traveling Shock in Non-uniform Coronal Conditions

    Science.gov (United States)

    Le Roux, J. A.; Arthur, A. D.

    2017-09-01

    Time-dependent solar energetic particle (SEP) acceleration is investigated at a fast, nearly parallel spherical traveling shock in the strongly non-uniform corona by solving the standard focused transport equation for SEPs and transport equations for parallel propagating Alfvén waves that form a set of coupled equations. This enables the modeling of self-excitation of Alfvén waves in the inertial range by SEPs ahead of the shock and its role in enhancing the efficiency of the diffusive shock acceleration (DSA) of SEPs in a self-regulatory fashion. Preliminary results suggest that, because of the highly non-uniform coronal conditions that the shock encounters, both DSA and wave excitation are highly time-dependent processes. Thus, DSA spectra of SEPs strongly deviate from the simple power-law prediction of standard steady-state DSA theory and initially strong wave excitation weakens rapidly. Consequently, the ability of DSA to produce high energy SEPs in the corona of ∼1 GeV, as observed in the strongest gradual SEP events, appears to be strongly curtailed at a fast nearly parallel shock, but further research is needed before final conclusions can be drawn.

  1. SU-D-204-07: Comparison of AAPM TG150 Draft Image Receptor Tests with Vendor Automated QC Tests for Five Mobile DR Units

    Energy Technology Data Exchange (ETDEWEB)

    Li, G; Nishino, T [UT MD Anderson Cancer Center, Houston, TX (United States); Greene, T [Radiation Services, Inc., Dover, FL (United States); Willis, C [MD Anderson Cancer Center, Bellaire, TX (United States)

    2015-06-15

    Purpose: To determine the consistency of digital detector (DR) tests recommended by AAPM TG150 and tests provided by commercially available DirectView Total Quality Tool (TQT). Methods: The DR tests recommended by the TG150 Detector Subgroup[1] were performed on 4 new Carestream DRX-Revolution and one Carestream DRX1C retrofit of a GE AMX-4 that had been in service for three years. After detector calibration, flat-field images plus images of two bar patterns oriented parallel and perpendicular to the A-C axis, were acquired at conditions recommended by TG150. Raw images were harvested and then analyzed using a MATLAB software previously validated[2,3,4]. Data were analyzed using ROIs of two different dimensions: 1) 128 x 128 ROIs matching the detector electronics; and 2) 256 x 256 ROIs, each including 4 adjacent smaller ROIs. TG150 metrics from 128 x 128 ROIs were compared to TQT metrics, which are also obtained from 128 x 128 ROIs[5]. Results: The results show that both TG150 and TQT measurements were consistent among these detectors. Differences between TG150 and TQT values appear systematic. Compared with 128 x 128 ROIs, noise and SNR non-uniformity were lower with 256 x 256 ROIs, although signal non-uniformity was similar, indicating detectors were appropriately calibrated for gain and offset. MTF of the retrofit unit remained essentially the same between 2012 and 2015, but was inferior to the new units. The older generator focal spot is smaller (0.75mm vs. 1.2mm), and the SID for acquisition is 182cm as well, so focal spot dimensions cannot explain the difference. The difference in MTF may be secondary to differences in generator X-ray spectrum or by unannounced changes in detector architecture. Further investigation is needed. Conclusion: The study shows that both TG150 and TQT tests are consistent. The numerical value of some metrics are dependent on ROI size.

  2. Return-on-Investment (ROI) Analyses of an Inpatient Lay Health Worker Model on 30-Day Readmission Rates in a Rural Community Hospital.

    Science.gov (United States)

    Cardarelli, Roberto; Bausch, Gregory; Murdock, Joan; Chyatte, Michelle Renee

    2017-07-07

    The purpose of the study was to assess the return-on-investment (ROI) of an inpatient lay health worker (LHW) model in a rural Appalachian community hospital impacting 30-day readmission rates. The Bridges to Home (BTH) study completed an evaluation in 2015 of an inpatient LHW model in a rural Kentucky hospital that demonstrated a reduction in 30-day readmission rates by 47.7% compared to a baseline period. Using the hospital's utilization and financial data, a validated ROI calculator specific to care transition programs was used to assess the ROI of the BTH model comparing 3 types of payment models including Diagnosis Related Group (DRG)-only payments, pay-for-performance (P4P) contracts, and accountable care organizations (ACOs). The BTH program had a -$0.67 ROI if the hospital had only a DRG-based payment model. If the hospital had P4P contracts with payers and 0.1% of its annual operating revenue was at risk, the ROI increased to $7.03 for every $1 spent on the BTH program. However, if the hospital was an ACO as was the case for this study's community hospital, the ROI significantly increased to $38.48 for every $1 spent on the BTH program. The BTH model showed a viable ROI to be considered by community hospitals that are part of an ACO or P4P program. A LHW care transition model may be a cost-effective alternative for impacting excess 30-day readmissions and avoiding associated penalties for hospital systems with a value-based payment model. © 2017 National Rural Health Association.

  3. Influence of Signal Intensity Non-Uniformity on Brain Volumetry Using an Atlas-Based Method

    International Nuclear Information System (INIS)

    Takao, Hidemasa; Kunimatsu, Akira; Mori, Harushi

    2012-01-01

    Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 X[measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials.

  4. Influence of signal intensity non-uniformity on brain volumetry using an atlas-based method.

    Science.gov (United States)

    Goto, Masami; Abe, Osamu; Miyati, Tosiaki; Kabasawa, Hiroyuki; Takao, Hidemasa; Hayashi, Naoto; Kurosu, Tomomi; Iwatsubo, Takeshi; Yamashita, Fumio; Matsuda, Hiroshi; Mori, Harushi; Kunimatsu, Akira; Aoki, Shigeki; Ino, Kenji; Yano, Keiichi; Ohtomo, Kuni

    2012-01-01

    Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 × [measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials.

  5. Influence of Signal Intensity Non-Uniformity on Brain Volumetry Using an Atlas-Based Method

    Energy Technology Data Exchange (ETDEWEB)

    Takao, Hidemasa; Kunimatsu, Akira; Mori, Harushi [University of Tokyo Hospital, Tokyo (Japan); and others

    2012-07-15

    Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 X[measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials.

  6. Spontaneous formation of non-uniform double helices for elastic rods under torsion

    International Nuclear Information System (INIS)

    Li, Hongyuan; Zhao, Shumin; Xia, Minggang; He, Siyu; Yang, Qifan; Yan, Yuming; Zhao, Hanqiao

    2017-01-01

    The spontaneous formation of double helices for filaments under torsion is common and significant. For example, the research on the supercoiling of DNA is helpful for understanding the replication and transcription of DNA. Similar double helices can appear in carbon nanotube yarns, cables, telephone wires and so forth. We noticed that non-uniform double helices can be produced due to the surface friction induced by the self-contact. Therefore an ideal model was presented to investigate the formation of double helices for elastic rods under torque. A general equilibrium condition which is valid for both the smooth surface and the rough surface situations is derived by using the variational method. By adding further constraints, the smooth and rough surface situations are investigated in detail respectively. Additionally, the model showed that the specific process of how to twist and slack the rod can determine the surface friction and hence influence the configuration of the double helix formed by rods with rough surfaces. Based on this principle, a method of manufacturing double helices with designed configurations was proposed and demonstrated. Finally, experiments were performed to verify the model and the results agreed well with the theory. - Highlights: • An ideal model is conceived to investigate the spontaneous formation of double helices for rods under torsion. • Variational method is used to obtain a universal result for the double helix formation process • Self-contact and surface friction is considered to analyze the non-uniform double helix. • A novel method of producing double helix with arbitrary configuration is proposed and demonstrated. • The experiment results agree well with the theory.

  7. Spontaneous formation of non-uniform double helices for elastic rods under torsion

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hongyuan [Department of Applied Physics, School of Science, Xi' an Jiaotong University, Shaanxi 710049 (China); Zhao, Shumin, E-mail: zhaosm@mail.xjtu.edu.cn [Department of Applied Physics, School of Science, Xi' an Jiaotong University, Shaanxi 710049 (China); Xia, Minggang [Department of Optical Information Science and Technology, School of Science, Xi' an Jiaotong University, 710049 (China); Laboratory of Nanostructure and Physics Properties, School of Science, Xi' an Jiaotong University, 710049 (China); He, Siyu [Department of Applied Physics, School of Science, Xi' an Jiaotong University, Shaanxi 710049 (China); Yang, Qifan [Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Shaanxi 710049 (China); Yan, Yuming [Department of Electrical Engineering and Automation, School of Electrical Engineering, Xi' an Jiaotong University, Shaanxi 710049 (China); Zhao, Hanqiao [Department of Biomedical Engineering, School of Life Science and Technology, Xi' an Jiaotong University, Shaanxi 710049 (China)

    2017-02-19

    The spontaneous formation of double helices for filaments under torsion is common and significant. For example, the research on the supercoiling of DNA is helpful for understanding the replication and transcription of DNA. Similar double helices can appear in carbon nanotube yarns, cables, telephone wires and so forth. We noticed that non-uniform double helices can be produced due to the surface friction induced by the self-contact. Therefore an ideal model was presented to investigate the formation of double helices for elastic rods under torque. A general equilibrium condition which is valid for both the smooth surface and the rough surface situations is derived by using the variational method. By adding further constraints, the smooth and rough surface situations are investigated in detail respectively. Additionally, the model showed that the specific process of how to twist and slack the rod can determine the surface friction and hence influence the configuration of the double helix formed by rods with rough surfaces. Based on this principle, a method of manufacturing double helices with designed configurations was proposed and demonstrated. Finally, experiments were performed to verify the model and the results agreed well with the theory. - Highlights: • An ideal model is conceived to investigate the spontaneous formation of double helices for rods under torsion. • Variational method is used to obtain a universal result for the double helix formation process • Self-contact and surface friction is considered to analyze the non-uniform double helix. • A novel method of producing double helix with arbitrary configuration is proposed and demonstrated. • The experiment results agree well with the theory.

  8. Compact Elliptically Tapered Slot Antenna with Non-uniform Corrugations for Ultra-wideband Applications

    Directory of Open Access Journals (Sweden)

    F. G. Zhu

    2013-04-01

    Full Text Available A small size elliptically tapered slot antenna (ETSA fed by coplanar waveguide (CPW for ultra-wideband (UWB applications is proposed. It is printed on an FR4 substrate and occupies a size of 37×34×0.8 mm^3. A pair of quarter circular shapes is etched on the radiator to reduce the size. To overcome the limitation of uniform corrugation, non-uniform corrugation is utilized to reduce the cross-polarization level. A parametric study is carried out to investigate the effects of circular cut and corrugations. In order to validate the design, a prototype is fabricated and measured. Both simulated and measured results confirm that the proposed antenna achieves a good performance of a reflection coefficient below -10 dB from 3.1 GHz to 10.6 GHz, including a maximum antenna gain of 8.1dBi, directional patterns in the end-fire direction, low cross-polarization level below -20 dB and linear phase response. The antenna is promising for applications in UWB impulse radar imaging.

  9. Non-uniform velocity profile mechanism for flame stabilization in a porous radiant burner

    Energy Technology Data Exchange (ETDEWEB)

    Catapan, R.C.; Costa, M. [Mechanical Engineering Department, Instituto Superior Tecnico, Technical University of Lisbon, Avenida Rovisco Pais, 1049-001 Lisbon (Portugal); Oliveira, A.A.M. [Mechanical Engineering Department, Federal University of Santa Catarina, Campus Universitario Professor Joao David Ferreira Lima, 88040-900 Florianopolis, SC (Brazil)

    2011-01-15

    Industrial processes where the heating of large surfaces is required lead to the possibility of using large surface porous radiant burners. This causes additional temperature uniformity problems, since it is increasingly difficult to evenly distribute the reactant mixture over a large burner surface while retaining its stability and keeping low pollutant emissions. In order to allow for larger surface area burners, a non-uniform velocity profile mechanism for flame stabilization in a porous radiant burner using a single large injection hole is proposed and analyzed for a double-layered burner operating in open and closed hot (laboratory-scale furnace, with temperature-controlled, isothermal walls) environments. In both environments, local mean temperatures within the porous medium have been measured. For lower reactant flow rate and ambient temperature the flame shape is conical and anchored at the rim of the injection hole. As the volumetric flow rate or furnace temperature is raised, the flame undergoes a transition to a plane flame stabilized near the external burner surface. However, the stability range envelope remains the same in both regimes. (author)

  10. Feeding biology of the introduced fish roi, and its impact on Hawaiian reef fishes, January 2004 and January 2005, (NODC Accession 0002172)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Feeding biology of the introduced fish roi (Cephalopholis argus), and its impact on Hawaiian reef fishes and fisheries between January 2004 and January 2005. Roi...

  11. Factorization of the hypergeometric-type difference equation on non-uniform lattices: dynamical algebra

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez-Nodarse, R [Departamento de Analisis Matematico, Universidad de Sevilla, Apdo. 1160, E-41080 Sevilla (Spain); Atakishiyev, N M [Instituto de Matematicas, UNAM, Apartado Postal 273-3, CP 62210 Cuernavaca, Morelos, Mexico (Germany); Costas-Santos, R S [Departamento de Matematicas, EPS, Universidad Carlos III de Madrid, Ave. Universidad 30, E-28911, Leganes, Madrid (Spain)

    2005-01-07

    We argue that one can factorize the difference equation of hypergeometric type on non-uniform lattices in the general case. It is shown that in the most cases of q-linear spectrum of the eigenvalues, this directly leads to the dynamical symmetry algebra su{sub q}(1, 1), whose generators are explicitly constructed in terms of the difference operators, obtained in the process of factorization. Thus all models with the q-linear spectrum (some of them, but not all, previously considered in a number of publications) can be treated in a unified form.

  12. Monte Carlo simulation of scatter in non-uniform symmetrical attenuating media for point and distributed sources

    International Nuclear Information System (INIS)

    Henry, L.J.; Rosenthal, M.S.

    1992-01-01

    We report results of scatter simulations for both point and distributed sources of 99m Tc in symmetrical non-uniform attenuating media. The simulations utilized Monte Carlo techniques and were tested against experimental phantoms. Both point and ring sources were used inside a 10.5 cm radius acrylic phantom. Attenuating media consisted of combinations of water, ground beef (to simulate muscle mass), air and bone meal (to simulate bone mass). We estimated/measured energy spectra, detector efficiencies and peak height ratios for all cases. In all cases, the simulated spectra agree with the experimentally measured spectra within 2 SD. Detector efficiencies and peak height ratios also are in agreement. The Monte Carlo code is able to properly model the non-uniform attenuating media used in this project. With verification of the simulations, it is possible to perform initial evaluation studies of scatter correction algorithms by evaluating the mechanisms of action of the correction algorithm on the simulated spectra where the magnitude and sources of scatter are known. (author)

  13. Broadband non-polarizing beam splitter based on guided mode resonance effect

    International Nuclear Information System (INIS)

    Ma Jian-Yong; Xu Cheng; Qiang Ying-Huai; Zhu Ya-Bo

    2011-01-01

    A broadband non-polarizing beam splitter (NPBS) operating in the telecommunication C+L band is designed by using the guided mode resonance effect of periodic silicon-on-insulator (SOI) elements. It is shown that this double layer SOI structure can provide ∼50/50 beam ratio with the maximum divergences between reflection and transmission being less than 8% over the spectrum of 1.4 μm∼1.7 μm and 1% in the telecommunication band for both TE and TM polarizations. The physical basis of this broadband non-polarizing property is on the simultaneous excitation of the TE and TM strong modulation waveguide modes near the designed spectrum band. Meanwhile, the electric field distributions for both TE and TM polarizations verify the resonant origin of spectrum in the periodic SOI structure. Furthermore, it is demonstrated with our calculations that the beam splitter proposed here is tolerant to the deviations of incident angle and structure parameters, which make it very easy to be fabricated with current IC technology. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  14. Policrystalline silicon used in microelectronic deposited in the LPCVD.-2: Uniformity and crystallinity

    International Nuclear Information System (INIS)

    Pastor, G.; Dominguez, C.; Lora-Tamayo, E.; Dominguez, E.

    1987-01-01

    The present work is a study about the uniformity of the silicon deposition in the LPCVD system starting out from the pure silane. It is concluded that it is necessary to take account of all the parameters involved (pressure, temperature, gas flow, number, position and spacing between wafers). From the point of view of the uniformity, three kinds of depositions are observed: poly uniform zone, poly non-uniform zone and amorphous precipitates zone. In the non-uniform zone the increase of the non-uniformity obeys an exponential low when only one of the parameters of the system changes. However, in the amorphous precipitates zone the non-uniformity tends to a constant value. By drawing the values of pressure (P) and gas flow (C), for a fixed temperature, that separates both the uniform/non-uniform and amorphous/policrystalline zones, the equation P n C m #alpha # K(T) are fulfilled where K is a function of temperature. 10 refs

  15. Effect of nonuniform radial density distribution on the space charge dominated beam bunching

    International Nuclear Information System (INIS)

    Sing Babu, P.; Goswami, A.; Pandit, V. S.

    2011-01-01

    Beam dynamics of a space charge dominated beam during the bunch compression is studied self consistently for the case of fixed shape non-uniform bell shape and hollow shape density distributions in the transverse direction. We have used thick slices at different parts of the beam to account for variation in the beam radius in the study of the transverse dynamics. The longitudinal dynamics has been studied using the disc model. The axial variation of the radius of the slices and emittance growth arising from the phase dependence of the transverse rf forces are also included in the simulation. We have modified the beam envelope equation to take into account the longitudinal space charge effect on the transverse motion which arises due to the finite bunch size. To demonstrate the application of the theoretical formulations developed, we have studied a sinusoidal beam bunching system and presented detailed numerical results.

  16. Non-uniform temperature gradients and thermal stresses produced ...

    Indian Academy of Sciences (India)

    thermally-induced stress distributions in a hollow steel sphere heated by a moving uniform ... models to evaluate temperatures according to the frictional heat generation, ... of these thermal effects include thermal stress, strain and deformation.

  17. Probabilistic uniformities of uniform spaces

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Lopez, J.; Romaguera, S.; Sanchis, M.

    2017-07-01

    The theory of metric spaces in the fuzzy context has shown to be an interesting area of study not only from a theoretical point of view but also for its applications. Nevertheless, it is usual to consider these spaces as classical topological or uniform spaces and there are not too many results about constructing fuzzy topological structures starting from a fuzzy metric. Maybe, H/{sup o}hle was the first to show how to construct a probabilistic uniformity and a Lowen uniformity from a probabilistic pseudometric /cite{Hohle78,Hohle82a}. His method can be directly translated to the context of fuzzy metrics and allows to characterize the categories of probabilistic uniform spaces or Lowen uniform spaces by means of certain families of fuzzy pseudometrics /cite{RL}. On the other hand, other different fuzzy uniformities can be constructed in a fuzzy metric space: a Hutton $[0,1]$-quasi-uniformity /cite{GGPV06}; a fuzzifiying uniformity /cite{YueShi10}, etc. The paper /cite{GGRLRo} gives a study of several methods of endowing a fuzzy pseudometric space with a probabilistic uniformity and a Hutton $[0,1]$-quasi-uniformity. In 2010, J. Guti/'errez Garc/'{/i}a, S. Romaguera and M. Sanchis /cite{GGRoSanchis10} proved that the category of uniform spaces is isomorphic to a category formed by sets endowed with a fuzzy uniform structure, i. e. a family of fuzzy pseudometrics satisfying certain conditions. We will show here that, by means of this isomorphism, we can obtain several methods to endow a uniform space with a probabilistic uniformity. Furthermore, these constructions allow to obtain a factorization of some functors introduced in /cite{GGRoSanchis10}. (Author)

  18. Feasibility of ceramic joining with high energy electron beams

    International Nuclear Information System (INIS)

    Turman, B.N.; Glass, S.J.; Halbleib, J.A.; Helmich, D.R.; Loehman, R.E.; Clifford, J.R.

    1995-01-01

    Joining structural ceramics is possible using high melting point metals such as Mo and Pt that are heated with a high energy electron beam, with the potential for producing joints with high temperature capability. A 10 MeV electron beam can penetrate through 1 cm of ceramic, offering the possibility of buried interface joining. Because of transient heating and the lower heat capacity of the metal relative to the ceramic, a pulsed high power beam has the potential for melting the metal without decomposing or melting the adjacent ceramic. The authors have demonstrated the feasibility of the process with a series of 10 MeV, 1 kW electron beam experiments. Shear strengths up to 28 NTa have been measured for Si 3 N 4 -Mo-Si 3 N 4 . These modest strengths are due to beam non-uniformity and the limited area of bonding. The bonding mechanism appears to be a thin silicide reaction layer. Si 3 N 4 -Si 3 N 4 joints with no metal layer were also produced, apparently bonded an yttrium apatite grain boundary phase

  19. Tuning for optimal performance in angle control, uniformity, and energy purity

    International Nuclear Information System (INIS)

    Liebert, Reuel B.; Olson, Joseph C.; Arevalo, Edwin A.; Downey, Daniel F.

    2005-01-01

    Advances in reducing the sizes of device structures and line widths place increasing demands on the accuracy of dopant placement and the control of dopant motion during activation anneals. Serial process high current ion implantation systems seek to produce beams in which the angles are controlled to high precision avoiding the angles introduced by conical structures used for holding wafers on spinning discs in batch systems. However, ion optical corrections and control of incident beam angle, dose uniformity, high throughput and energy purity often present apparently contradictory requirements in machine design. Data is presented to illustrate that tuning procedures can be used to simultaneously optimize angle purity in both x and y planes as well as control energy purity and dose uniformity

  20. The effect of nonlinear propagation on heating of tissue: A numerical model of diagnostic ultrasound beams

    Science.gov (United States)

    Cahill, Mark D.; Humphrey, Victor F.; Doody, Claire

    2000-07-01

    Thermal safety indices for diagnostic ultrasound beams are calculated under the assumption that the sound propagates under linear conditions. A non-axisymmetric finite difference model is used to solve the KZK equation, and so to model the beam of a diagnostic scanner in pulsed Doppler mode. Beams from both a uniform focused rectangular source and a linear array are considered. Calculations are performed in water, and in attenuating media with tissue-like characteristics. Attenuating media are found to exhibit significant nonlinear effects for finite-amplitude beams. The resulting loss of intensity by the beam is then used as the source term in a model of tissue heating to estimate the maximum temperature rises. These are compared with the thermal indices, derived from the properties of the water-propagated beams.

  1. Uniformity analysis for a direct-drive laser fusion reactor

    International Nuclear Information System (INIS)

    Lund, L.D.; Skupsky, S.; Goldman, L.M.

    1983-01-01

    We show the results of an analysis of the uniformity for a direct-drive reactor using 20, 32, 60, or 96 beams. Several of these options achieve less than the 1% nonuniformity that is required. These options are considered for the cases where the solid angle fraction of the beam ports is 2% and 8%. The analysis is facilitated by separating the contributions due to the geometrical effects related to the number and orientation of the beams from those due to the spatial profile of the individual beams. Emphasis is placed on the wavelength of the nonuniformities, as the shorter wavelength nonuniformities are more easily smoothed by thermal conduction within the target. The analysis demonstrates that the longer wavelengths can be minimized by suitable choices of geometry and by maintaining beam balance, whereas the shorter wavelength nonuniformities can be reduced by optimizing parameters such as the focal position and the spatial intensity profile of each beam. The tolerances required for beam-to-beam energy balance will be discussed

  2. Photoionization microscopy of Rydberg hydrogen atom in a non-uniform electrical field

    International Nuclear Information System (INIS)

    Cheng Shao-Hao; Wang De-Hua; Chen Zhao-Hang; Chen Qiang

    2016-01-01

    In this paper, we investigate the photoionization microscopy of the Rydberg hydrogen atom in a gradient electric field for the first time. The observed oscillatory patterns in the photoionization microscopy are explained within the framework of the semiclassical theory, which can be considered as a manifestation of interference between various electron trajectories arriving at a given point on the detector plane. In contrast with the photoionization microscopy in the uniform electric field, the trajectories of the ionized electron in the gradient electric field will become chaotic. An infinite set of different electron trajectories can arrive at a given point on the detector plane, which makes the interference pattern of the electron probability density distribution extremely complicated. Our calculation results suggest that the oscillatory pattern in the electron probability density distribution depends sensitively on the electric field gradient, the scaled energy and the position of the detector plane. Through our research, we predict that the interference pattern in the electron probability density distribution can be observed in an actual photoionization microscopy experiment once the external electric field strength and the position of the electron detector plane are reasonable. This study provides some references for the future experimental research on the photoionization microscopy of the Rydberg atom in the non-uniform external fields. (paper)

  3. Modeling and Compensating Temperature-Dependent Non-Uniformity Noise in IR Microbolometer Cameras

    Directory of Open Access Journals (Sweden)

    Alejandro Wolf

    2016-07-01

    Full Text Available Images rendered by uncooled microbolometer-based infrared (IR cameras are severely degraded by the spatial non-uniformity (NU noise. The NU noise imposes a fixed-pattern over the true images, and the intensity of the pattern changes with time due to the temperature instability of such cameras. In this paper, we present a novel model and a compensation algorithm for the spatial NU noise and its temperature-dependent variations. The model separates the NU noise into two components: a constant term, which corresponds to a set of NU parameters determining the spatial structure of the noise, and a dynamic term, which scales linearly with the fluctuations of the temperature surrounding the array of microbolometers. We use a black-body radiator and samples of the temperature surrounding the IR array to offline characterize both the constant and the temperature-dependent NU noise parameters. Next, the temperature-dependent variations are estimated online using both a spatially uniform Hammerstein-Wiener estimator and a pixelwise least mean squares (LMS estimator. We compensate for the NU noise in IR images from two long-wave IR cameras. Results show an excellent NU correction performance and a root mean square error of less than 0.25 ∘ C, when the array’s temperature varies by approximately 15 ∘ C.

  4. Negatons, positons, rational-like solutions and conservation laws of the Korteweg-de Vries equation with loss and non-uniformity terms

    International Nuclear Information System (INIS)

    Zhang Dajun; Chen Dengyuan

    2004-01-01

    Solitons, negatons, positons, rational-like solutions and mixed solutions of a non-isospectral equation, the Korteweg-de Vries equation with loss and non-uniformity terms, are obtained through the Wronskian technique. The non-isospectral characteristics of the motion behaviours of some solutions are described with some figures made by using Mathematica. We also derive an infinite number of conservation laws of the equation

  5. Non-uniform dispersion of the source-sink relationship alters wavefront curvature.

    Directory of Open Access Journals (Sweden)

    Lucia Romero

    Full Text Available The distribution of cellular source-sink relationships plays an important role in cardiac propagation. It can lead to conduction slowing and block as well as wave fractionation. It is of great interest to unravel the mechanisms underlying evolution in wavefront geometry. Our goal is to investigate the role of the source-sink relationship on wavefront geometry using computer simulations. We analyzed the role of variability in the microscopic source-sink relationship in driving changes in wavefront geometry. The electrophysiological activity of a homogeneous isotropic tissue was simulated using the ten Tusscher and Panfilov 2006 action potential model and the source-sink relationship was characterized using an improved version of the Romero et al. safety factor formulation (SFm2. Our simulations reveal that non-uniform dispersion of the cellular source-sink relationship (dispersion along the wavefront leads to alterations in curvature. To better understand the role of the source-sink relationship in the process of wave formation, the electrophysiological activity at the initiation of excitation waves in a 1D strand was examined and the source-sink relationship was characterized using the two recently updated safety factor formulations: the SFm2 and the Boyle-Vigmond (SFVB definitions. The electrophysiological activity at the initiation of excitation waves was intimately related to the SFm2 profiles, while the SFVB led to several counterintuitive observations. Importantly, with the SFm2 characterization, a critical source-sink relationship for initiation of excitation waves was identified, which was independent of the size of the electrode of excitation, membrane excitability, or tissue conductivity. In conclusion, our work suggests that non-uniform dispersion of the source-sink relationship alters wavefront curvature and a critical source-sink relationship profile separates wave expansion from collapse. Our study reinforces the idea that the

  6. Assessment of 12 CHF prediction methods, for an axially non-uniform heat flux distribution, with the RELAP5 computer code

    Energy Technology Data Exchange (ETDEWEB)

    Ferrouk, M. [Laboratoire du Genie Physique des Hydrocarbures, University of Boumerdes, Boumerdes 35000 (Algeria)], E-mail: m_ferrouk@yahoo.fr; Aissani, S. [Laboratoire du Genie Physique des Hydrocarbures, University of Boumerdes, Boumerdes 35000 (Algeria); D' Auria, F.; DelNevo, A.; Salah, A. Bousbia [Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Universita di Pisa (Italy)

    2008-10-15

    The present article covers the evaluation of the performance of twelve critical heat flux methods/correlations published in the open literature. The study concerns the simulation of an axially non-uniform heat flux distribution with the RELAP5 computer code in a single boiling water reactor channel benchmark problem. The nodalization scheme employed for the considered particular geometry, as modelled in RELAP5 code, is described. For this purpose a review of critical heat flux models/correlations applicable to non-uniform axial heat profile is provided. Simulation results using the RELAP5 code and those obtained from our computer program, based on three type predictions methods such as local conditions, F-factor and boiling length average approaches were compared.

  7. Beam-beam phenomenology

    International Nuclear Information System (INIS)

    Teng, L.C.

    1980-01-01

    In colliding beam storage rings the beam collision regions are generally so short that the beam-beam interaction can be considered as a series of evenly spaced non-linear kicks superimposed on otherwise stable linear oscillations. Most of the numerical studies on computers were carried out in just this manner. But for some reason this model has not been extensively employed in analytical studies. This is perhaps because all analytical work has so far been done by mathematicians pursuing general transcendental features of non-linear mechanics for whom this specific model of the specific system of colliding beams is too parochial and too repugnantly physical. Be that as it may, this model is of direct interest to accelerator physicists and is amenable to (1) further simplification, (2) physical approximation, and (3) solution by analogy to known phenomena

  8. Joint beam design and user selection over non-binary coded MIMO interference channel

    Science.gov (United States)

    Li, Haitao; Yuan, Haiying

    2013-03-01

    In this paper, we discuss the problem of sum rate improvement for coded MIMO interference system, and propose joint beam design and user selection over interference channel. Firstly, we have formulated non-binary LDPC coded MIMO interference networks model. Then, the least square beam design for MIMO interference system is derived, and the low complexity user selection is presented. Simulation results confirm that the sum rate can be improved by the joint user selection and beam design comparing with single interference aligning beamformer.

  9. Usefulness of a three-dimensional stereotaxic ROI template on anatomically standardised {sup 99m}Tc-ECD SPET

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Ryo [Department of Internal Medicine, Division of Nuclear Medicine, Nishi-Kobe Medical Center, Kobe (Japan); Yonekura, Yoshiharu [Biomedical Imaging Research Center, Fukui Medical University, Fukui (Japan); Matsuda, Hiroshi [Department of Radiology, National Center Hospital for Mental, Tokyo (Japan); Konishi, Junji [Department of Nuclear Medicine and Diagnostic Imaging, Graduate School of Medicine, Kyoto University, Kyoto (Japan)

    2002-03-01

    We have constructed a three-dimensional stereotaxic ROI template (3DSRT) on anatomically standardised cerebral blood flow (CBF) single-photon emission tomography (SPET) images to objectively estimate regional CBF (rCBF). The 3DSRT is composed of 259 regions of interest (ROIs) in 11 segments (1, superior frontal; 2, middle and inferior frontal; 3, primary sensorimotor; 4, parietal; 5, angular; 6, temporal; 7, occipital; 8, pericallosal; 9, lenticular nucleus; 10, thalamus; 11, hippocampus) on each side. We measured the rCBF values of the 518 ROIs and calculated the area-weighted average (segmental CBF; sCBF) of the 22 segments based on the rCBF in each ROI. We compared vascular reserve before and after revascularisation surgery using sCBF on anatomically standardised resting and acetazolamide (Acz)-challenged CBF SPET images, which were obtained using an equal-volume-split dual-injection single-day protocol [resting and vascular reserve (RVR) method] in 13 patients who had not suffered any major stroke but did have significant cerebrovascular stenosis. Prior to the evaluation, we examined the sCBF values of 16 subjects with various cerebrovascular conditions (8, normal; 3, lacunar infarction; 2, chronic infarction; 2, meningioma; 1, aneurysm) using physiological saline instead of Acz (placebo study) in order to confirm the reproducibility of the RVR method. In the placebo study we observed excellent linearity (y=1.444+0.964x) between the 352 pairs of baseline (x) and post-placebo (y) sCBF values in the 16 subjects, irrespective of the segment location. In all of the 13 patients, estimation of sCBF demonstrated impaired vascular reserve pre-operatively and improved vascular reserve postoperatively. We conclude that the 3DSRT, which could be identically set on the anatomically standardised images obtained at baseline and after Acz injection, allowed objective assessment of the pre- and postoperative vascular reserve, which was not easy with conventional ROI settings

  10. Beam-beam interaction in e+-e- storage rings

    International Nuclear Information System (INIS)

    Le Duff, J.

    1977-01-01

    Colliding beams in electron-positron storage rings are discussed with particular reference to the space charge forces occuring during beam-beam interactions and their effect on beam current and consequently machine performance (maximum luminosity). The first section deals with linear beam-beam effects and discussses linear tune shift; the second section considers non-linear beam-beam effects and the creation on non-linear resonances. The last section poses questions of the possibility of extrapolating present results to future machines and discusses optimization of storage ring performance. (B.D.)

  11. Current-Voltage Characteristic of Nanosecond - Duration Relativistic Electron Beam

    Science.gov (United States)

    Andreev, Andrey

    2005-10-01

    The pulsed electron-beam accelerator SINUS-6 was used to measure current-voltage characteristic of nanosecond-duration thin annular relativistic electron beam accelerated in vacuum along axis of a smooth uniform metal tube immersed into strong axial magnetic field. Results of these measurements as well as results of computer simulations performed using 3D MAGIC code show that the electron-beam current dependence on the accelerating voltage at the front of the nanosecond-duration pulse is different from the analogical dependence at the flat part of the pulse. In the steady-state (flat) part of the pulse), the measured electron-beam current is close to Fedosov current [1], which is governed by the conservation law of an electron moment flow for any constant voltage. In the non steady-state part (front) of the pulse, the electron-beam current is higher that the appropriate, for a giving voltage, steady-state (Fedosov) current. [1] A. I. Fedosov, E. A. Litvinov, S. Ya. Belomytsev, and S. P. Bugaev, ``Characteristics of electron beam formed in diodes with magnetic insulation,'' Soviet Physics Journal (A translation of Izvestiya VUZ. Fizika), vol. 20, no. 10, October 1977 (April 20, 1978), pp.1367-1368.

  12. Direct-driven target implosion in heavy ion fusion

    International Nuclear Information System (INIS)

    Noguchi, K.; Suzuki, T.; Kurosaki, T.; Barada, D.; Kawata, S.; Ma, Y. Y.; Ogoyski, A. I.

    2016-01-01

    In inertial confinement fusion, the driver beam illumination non-uniformity leads a degradation of fusion energy output. A fuel target alignment error would happen in a fusion reactor; the target alignment error induces heavy ion beam illumination non-uniformity on a target. On the other hand, heavy ion beam accelerator provides a capability to oscillate a beam axis with a high frequency. The wobbling beams may provide a new method to reduce or smooth the beam illumination non-uniformity. First we study the effect of driver irradiation non-uniformity induced by the target alignment error (dz) on the target implosion. We found that dz should be less than about 130 μm for a sufficient fusion energy output. We also optimize the wobbling scheme. The spiral wobbling heavy ion beams would provide a promissing scheme to the uniform beam illumination. (paper)

  13. Non-uniform interhemispheric temperature trends over the past 550 years

    Energy Technology Data Exchange (ETDEWEB)

    Duncan, Richard P. [Landcare Research, PO Box 40, Lincoln (New Zealand); Lincoln University, Bio-Protection Research Centre, PO Box 84, Lincoln (New Zealand); Fenwick, Pavla; Palmer, Jonathan G. [Gondwana Tree-ring Laboratory, PO Box 14, Canterbury (New Zealand); McGlone, Matt S. [Landcare Research, PO Box 40, Lincoln (New Zealand); Turney, Chris S.M. [University of Exeter, School of Geography, Exeter (United Kingdom)

    2010-12-15

    The warming trend over the last century in the northern hemisphere (NH) was interrupted by cooling from ad 1940 to 1975, a period during which the southern hemisphere experienced pronounced warming. The cause of these departures from steady warming at multidecadal timescales are unclear; the prevailing explanation is that they are driven by non-uniformity in external forcings but recent models suggest internal climate drivers may play a key role. Paleoclimate datasets can help provide a long-term perspective. Here we use tree-rings to reconstruct New Zealand mean annual temperature over the last 550 years and demonstrate that this has frequently cycled out-of-phase with NH mean annual temperature at a periodicity of around 30-60 years. Hence, observed multidecadal fluctuations around the recent warming trend have precedents in the past, strongly implicating natural climate variation as their cause. We consider the implications of these changes in understanding and modelling future climate change. (orig.)

  14. The small length scale effect for a non-local cantilever beam: a paradox solved.

    Science.gov (United States)

    Challamel, N; Wang, C M

    2008-08-27

    Non-local continuum mechanics allows one to account for the small length scale effect that becomes significant when dealing with microstructures or nanostructures. This paper presents some simplified non-local elastic beam models, for the bending analyses of small scale rods. Integral-type or gradient non-local models abandon the classical assumption of locality, and admit that stress depends not only on the strain value at that point but also on the strain values of all points on the body. There is a paradox still unresolved at this stage: some bending solutions of integral-based non-local elastic beams have been found to be identical to the classical (local) solution, i.e. the small scale effect is not present at all. One example is the Euler-Bernoulli cantilever nanobeam model with a point load which has application in microelectromechanical systems and nanoelectromechanical systems as an actuator. In this paper, it will be shown that this paradox may be overcome with a gradient elastic model as well as an integral non-local elastic model that is based on combining the local and the non-local curvatures in the constitutive elastic relation. The latter model comprises the classical gradient model and Eringen's integral model, and its application produces small length scale terms in the non-local elastic cantilever beam solution.

  15. New non-orthogonality treatment for atmospheric boundary layer flow simulation above highly non-uniform terrains

    Directory of Open Access Journals (Sweden)

    Mirkov Nikola S.

    2016-01-01

    Full Text Available In this paper we validate an improved finite volume approximation of Reynolds Averaged Navier-Stokes equations for simulation of wind flows in body-fitted grids generated by algebraic extrusion from digital terrain elevation data, proposed in N. Mirkov et. al. J. Comput. Phys. 287, 18-45(2015, [1]. The approach is based on second-order accurate finite volume method with collocated variable arrangement and pressure-velocity coupling trough SIMPLE algorithm. The main objective is the attenuation of spurious pressure field oscillations in regions with discontinuity in grid line slopes, as encountered in grids representing highly non-uniform terrains. Moreover, the approach relaxes the need for grid generation based on elliptic PDEs or grid smoothing by applying fixed point iterations (i.e. Gauss-Seidel to initial grid node positions resulting from algebraic grid generators. Drawbacks of previous approaches which ignored treatment of finite volume grid cell cases with intersection point offset in non-orthogonality corrections are removed. Application to real-life wind farm project at Dobrič (Srvljig, Serbia is used to assess the effectiveness of the method. The results validate the view in which accurate discretization of governing equations play more important role than the choice of turbulence modelling closures. [Projekat Ministarstva nauke Republike Srbije, br. TR-33036

  16. Oscillations of a Beam on a Non-Linear Elastic Foundation under Periodic Loads

    Directory of Open Access Journals (Sweden)

    Donald Mark Santee

    2006-01-01

    Full Text Available The complexity of the response of a beam resting on a nonlinear elastic foundation makes the design of this structural element rather challenging. Particularly because, apparently, there is no algebraic relation for its load bearing capacity as a function of the problem parameters. Such an algebraic relation would be desirable for design purposes. Our aim is to obtain this relation explicitly. Initially, a mathematical model of a flexible beam resting on a non-linear elastic foundation is presented, and its non-linear vibrations and instabilities are investigated using several numerical methods. At a second stage, a parametric study is carried out, using analytical and semi-analytical perturbation methods. So, the influence of the various physical and geometrical parameters of the mathematical model on the non-linear response of the beam is evaluated, in particular, the relation between the natural frequency and the vibration amplitude and the first period doubling and saddle-node bifurcations. These two instability phenomena are the two basic mechanisms associated with the loss of stability of the beam. Finally Melnikov's method is used to determine an algebraic expression for the boundary that separates a safe from an unsafe region in the force parameters space. It is shown that this can be used as a basis for a reliable engineering design criterion.

  17. Proposal for a Domain Wall Nano-Oscillator driven by Non-uniform Spin Currents

    Science.gov (United States)

    Sharma, Sanchar; Muralidharan, Bhaskaran; Tulapurkar, Ashwin

    2015-09-01

    We propose a new mechanism and a related device concept for a robust, magnetic field tunable radio-frequency (rf) oscillator using the self oscillation of a magnetic domain wall subject to a uniform static magnetic field and a spatially non-uniform vertical dc spin current. The self oscillation of the domain wall is created as it translates periodically between two unstable positions, one being in the region where both the dc spin current and the magnetic field are present, and the other, being where only the magnetic field is present. The vertical dc spin current pushes it away from one unstable position while the magnetic field pushes it away from the other. We show that such oscillations are stable under noise and can exhibit a quality factor of over 1000. A domain wall under dynamic translation, not only being a source for rich physics, is also a promising candidate for advancements in nanoelectronics with the actively researched racetrack memory architecture, digital and analog switching paradigms as candidate examples. Devising a stable rf oscillator using a domain wall is hence another step towards the realization of an all domain wall logic scheme.

  18. Compensation of non-ideal beam splitter polarization distortion effect in Michelson interferometer

    Science.gov (United States)

    Liu, Yeng-Cheng; Lo, Yu-Lung; Liao, Chia-Chi

    2016-02-01

    A composite optical structure consisting of two quarter-wave plates and a single half-wave plate is proposed for compensating for the polarization distortion induced by a non-ideal beam splitter in a Michelson interferometer. In the proposed approach, the optimal orientations of the optical components within the polarization compensator are determined using a genetic algorithm (GA) such that the beam splitter can be treated as a free-space medium and modeled using a unit Mueller matrix accordingly. Two implementations of the proposed polarization controller are presented. In the first case, the compensator is placed in the output arm of Michelson interferometer such that the state of polarization of the interfered output light is equal to that of the input light. However, in this configuration, the polarization effects induced by the beam splitter in the two arms of the interferometer structure cannot be separately addressed. Consequently, in the second case, compensator structures are placed in the Michelson interferometer for compensation on both the scanning and reference beams. The practical feasibility of the proposed approach is introduced by considering a Mueller polarization-sensitive (PS) optical coherence tomography (OCT) structure with three polarization controllers in the input, reference and sample arms, respectively. In general, the results presented in this study show that the proposed polarization controller provides an effective and experimentally-straightforward means of compensating for the polarization distortion effects induced by the non-ideal beam splitters in Michelson interferometers and Mueller PS-OCT structures.

  19. Intense non-relativistic cesium ion beam

    International Nuclear Information System (INIS)

    Lampel, M.C.

    1984-02-01

    The Heavy Ion Fusion group at Lawrence Berkeley Laboratory has constructed the One Ampere Cesium Injector as a proof of principle source to supply an induction linac with a high charge density and high brightness ion beam. This is studied here. An electron beam probe was developed as the major diagnostic tool for characterizing ion beam space charge. Electron beam probe data inversion is accomplished with the EBEAM code and a parametrically adjusted model radial charge distribution. The longitudinal charge distribution was not derived, although it is possible to do so. The radial charge distribution that is derived reveals an unexpected halo of trapped electrons surrounding the ion beam. A charge fluid theory of the effect of finite electron temperature on the focusing of neutralized ion beams (Nucl. Fus. 21, 529 (1981)) is applied to the problem of the Cesium beam final focus at the end of the injector. It is shown that the theory's predictions and assumptions are consistent with the experimental data, and that it accounts for the observed ion beam radius of approx. 5 cm, and the electron halo, including the determination of an electron Debye length of approx. 10 cm

  20. Quantitative analysis of artifacts in 4D DSA: the relative contributions of beam hardening and scatter to vessel dropout behind highly attenuating structures

    Science.gov (United States)

    Hermus, James; Szczykutowicz, Timothy P.; Strother, Charles M.; Mistretta, Charles

    2014-03-01

    When performing Computed Tomographic (CT) image reconstruction on digital subtraction angiography (DSA) projections, loss of vessel contrast has been observed behind highly attenuating anatomy, such as dental implants and large contrast filled aneurysms. Because this typically occurs only in a limited range of projection angles, the observed contrast time course can potentially be altered. In this work, we have developed a model for acquiring DSA projections that models both the polychromatic nature of the x-ray spectrum and the x-ray scattering interactions to investigate this problem. In our simulation framework, scatter and beam hardening contributions to vessel dropout can be analyzed separately. We constructed digital phantoms with large clearly defined regions containing iodine contrast, bone, soft issue, titanium (dental implants) or combinations of these materials. As the regions containing the materials were large and rectangular, when the phantoms were forward projected, the projections contained uniform regions of interest (ROI) and enabled accurate vessel dropout analysis. Two phantom models were used, one to model the case of a vessel behind a large contrast filled aneurysm and the other to model a vessel behind a dental implant. Cases in which both beam hardening and scatter were turned off, only scatter was turned on, only beam hardening was turned on, and both scatter and beam hardening were turned on, were simulated for both phantom models. The analysis of this data showed that the contrast degradation is primarily due to scatter. When analyzing the aneurysm case, 90.25% of the vessel contrast was lost in the polychromatic scatter image, however only 50.5% of the vessel contrast was lost in the beam hardening only image. When analyzing the teeth case, 44.2% of the vessel contrast was lost in the polychromatic scatter image and only 26.2% of the vessel contrast was lost in the beam hardening only image.