  1. Electron Beam Dose Distribution in the Presence of Non-Uniform Magnetic Field

    Directory of Open Access Journals (Sweden)

    Mohamad Javad Tahmasebi-Birgani

    2014-04-01

    Full Text Available Introduction Magnetic fields are capable of altering the trajectory of electron beams andcan be used in radiation therapy.Theaim of this study was to produce regions with dose enhancement and reduction in the medium. Materials and Methods The NdFeB permanent magnets were arranged on the electron applicator in several configurations. Then, after the passage of the electron beams (9 and 15 MeV Varian 2100C/D through the non-uniform magnetic field, the Percentage Depth Dose(PDDs on central axis and dose profiles in three depths for each energy were measured in a 3D water phantom. Results For all magnet arrangements and for two different energies, the surface dose increment and shift in depth of maximum dose (dmax were observed. In addition, the pattern of dose distribution in buildup region was changed. Measurement of dose profile showed dose localization and spreading in some other regions. Conclusion The results of this study confirms that using magnetic field can alter the dose deposition patterns and as a result can produce dose enhancement as well as dose reduction in the medium using high-energy electron beams. These effects provide dose distribution with arbitrary shapes for use in radiation therapy.

  2. Below-threshold harmonic generation from strong non-uniform fields

    Science.gov (United States)

    Yavuz, I.

    2017-10-01

    Strong-field photoemission below the ionization threshold is a rich/complex region where atomic emission and harmonic generation may coexist. We studied the mechanism of below-threshold harmonics (BTH) from spatially non-uniform local fields near the metallic nanostructures. Discrete harmonics are generated due to the broken inversion symmetry, suggesting enriched coherent emission in the vuv frequency range. Through the numerical solution of the time-dependent Schrödinger equation, we investigate wavelength and intensity dependence of BTH. Wavelength dependence identifies counter-regular resonances; individual contributions from the multi-photon emission and channel-closing effects due to quantum path interferences. In order to understand the underlying mechanism of BTH, we devised a generalized semi-classical model, including the influence of Coulomb and non-uniform field interactions. As in uniform fields, Coulomb potential in non-uniform fields is the determinant of BTH; we observed that the generation of BTH are due to returning trajectories with negative energies. Due to large distance effectiveness of the non-uniformity, only long trajectories are noticeably affected.

  3. The Consequence of Self-field and Non-uniform Current Distribution on Short Sample Tests of Superconducting Cables

    CERN Document Server

    Verweij, A P

    1998-01-01

    Electrical measurements on samples of superconducting cables are usually performed in order to determine the critical current $I_c$ and the n-value, assuming that the voltage U at the transition from the superconducting to the normal state follows the power law, U\\sim($I/I_c$)$^n$. An accurate measurement of $I_c$ and n demands, first of all, good control of temperature and field, and precise measurement of current and voltage. The critical current and n-value of a cable are influenced by the self-field of the cable, an effect that has to be known in order to compare the electrical characteristics of the cable with those of the strands from which it is made. The effect of the self-field is dealt with taking into account the orientation and magnitude of the applied field and the n-value of the strands. An important source of inaccuracy is related to the distribution of the currents among the strands. Non-uniform distributions, mainly caused by non-equal resistances of the connections between the strands of the...

  4. Measurement of fuel importance distribution in non-uniformly distributed fuel systems

    International Nuclear Information System (INIS)

    Yamane, Yoshihiro; Hirano, Yasushi; Yasui, Hazime; Izima, Kazunori; Shiroya, Seiji; Kobayashi, Keiji.

    1995-01-01

    A reactivity effect due to a spatial variation of nuclear fuel concentration is an important problem for nuclear criticality safety in a reprocessing plant. As a theory estimating this reactivity effect, the Goertzel and fuel importance theories are well known. It has been shown that the Goertzel's theory is valid in the range of our experiments based on measurements of reactivity effect and thermal neutron flux in non-uniformly distributed fuel systems. On the other hand, there have been no reports concerning systematic experimental studies on the flatness of fuel importance which is a more general index than the Goertzel's theory. It is derived from the perturbation theory that the fuel importance is proportional to the reactivity change resulting from a change of small amount of fuel mass. Using a uniform and three kinds of nonuniform fuel systems consisting of 93.2% enriched uranium plates and polyethylene plates, the fuel importance distributions were measured. As a result, it was found experimentally that the fuel importance distribution became flat, as its reactivity effect became large. Therefore it was concluded that the flatness of fuel importance distribution is the useful index for estimating reactivity effect of non-uniformly distributed fuel system. (author)

  5. The magnetostriction in a superconductor-magnet system under non-uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xueyi; Jiang, Lang; Wu, Hao [Key Laboratory of Mechanics on Disaster and Environment in Western China attached to the Ministry of Education of China, Lanzhou University, Lanzhou, Gansu 730000 (China); Gao, Zhiwen, E-mail: gaozhw@lzu.edu.cn [Department of Mechanics and Engineering Science, College of Civil Engineering and Mechanics, Lanzhou University, Lanzhou, Gansu 730000 (China)

    2017-03-15

    Highlights: • We studied firstly magnetostriction in HTS under non-uniform magnetic field. • The superconductors may be homogeneous and nonhomogeneous. • The magnetostrictions response of the HTS is sensitive to the critical current density and amplitude of the applied magnetic field. • The magnetostriction of nonhomogeneous HTS is larger than that of homogeneous HTS. - Abstract: This paper describes a numerical model to examine the magnetostriction of bulk high-temperature superconductor (HTS) under non-uniform magnetic field in conjunction with finite element analysis. Through this model, the magnetostriction of homogeneous and nonhomogeneous HTS can be implemented under non-uniform magnetic field. Further, the effects of critical current density, applied field frequency and amplitude are also considered. The computational study can provide a fundamental mechanistic understanding the effects of non-uniform magnetic field on magnetostriction of HTS.

  6. Photoionization microscopy of Rydberg hydrogen atom in a non-uniform electrical field

    International Nuclear Information System (INIS)

    Cheng Shao-Hao; Wang De-Hua; Chen Zhao-Hang; Chen Qiang

    2016-01-01

    In this paper, we investigate the photoionization microscopy of the Rydberg hydrogen atom in a gradient electric field for the first time. The observed oscillatory patterns in the photoionization microscopy are explained within the framework of the semiclassical theory, which can be considered as a manifestation of interference between various electron trajectories arriving at a given point on the detector plane. In contrast with the photoionization microscopy in the uniform electric field, the trajectories of the ionized electron in the gradient electric field will become chaotic. An infinite set of different electron trajectories can arrive at a given point on the detector plane, which makes the interference pattern of the electron probability density distribution extremely complicated. Our calculation results suggest that the oscillatory pattern in the electron probability density distribution depends sensitively on the electric field gradient, the scaled energy and the position of the detector plane. Through our research, we predict that the interference pattern in the electron probability density distribution can be observed in an actual photoionization microscopy experiment once the external electric field strength and the position of the electron detector plane are reasonable. This study provides some references for the future experimental research on the photoionization microscopy of the Rydberg atom in the non-uniform external fields. (paper)

  7. Non-uniform temperature field measurement and simulation of a radio telescope’s main reflector under solar radiation

    International Nuclear Information System (INIS)

    Chen, Deshen; Qian, Hongliang; Wang, Huajie; Zhang, Gang; Fan, Feng; Shen, Shizhao

    2017-01-01

    Highlights: • Solar non-uniform temperature field test of a telescope’s reflector is conducted initially. • Time-varying distribution regularities are analyzed contrastively. • Simulation methods are proposed involving environmental factors and self-shadowing. • Refined discrimination method for the shadow distribution is put forward. • Validity of simulation methods is evaluated with the experimental data. - Abstract: To improve the ability of deep-space exploration, many astronomers around the world are actively engaged in the construction of large-aperture and high-precision radio telescopes. The temperature effect is one of three main factors affecting the reflector accuracy of radio telescopes. To study the daily non-uniform temperature field of the main reflector, experimental studies are first carried out with a 3-m-aperture radio telescope model. According to the test results for 16 working conditions, the distribution rule and time-varying regularity of the daily temperature field are summarized initially. Next, theoretical methods for the temperature field of the main reflector are studied considering multiple environmental parameters and self-shadows. Finally, the validity of the theoretical methods is evaluated with test results. The experimental study demonstrates that the non-uniform temperature distribution of the main reflector truly exists and should not be overlooked, and that the theoretical methods for the reflector temperature field proposed in this paper are effective. The research methods and conclusions can provide valuable references for thermal design, monitoring and control of similar high-precision radio telescopes.

  8. Modeling of parallel-plate regenerators with non-uniform plate distributions

    DEFF Research Database (Denmark)

    Jensen, Jesper Buch; Engelbrecht, Kurt; Bahl, Christian Robert Haffenden

    2010-01-01

    plate spacing distributions are presented in order to understand the impact of spacing non-uniformity. Simulations of more realistic distributions where the plate spacings follow normal distributions are then discussed in order to describe the deviation of the performance of a regenerator relative...

  9. Shape and fission instabilities of ferrofluids in non-uniform magnetic fields

    Science.gov (United States)

    Vieu, Thibault; Walter, Clément

    2018-04-01

    We study static distributions of ferrofluid submitted to non-uniform magnetic fields. We show how the normal-field instability is modified in the presence of a weak magnetic field gradient. Then we consider a ferrofluid droplet and show how the gradient affects its shape. A rich phase transitions phenomenology is found. We also investigate the creation of droplets by successive splits when a magnet is vertically approached from below and derive theoretical expressions which are solved numerically to obtain the number of droplets and their aspect ratio as function of the field configuration. A quantitative comparison is performed with previous experimental results, as well as with our own experiments, and yields good agreement with the theoretical modeling.

  10. The demagnetizing field of a non-uniform rectangular prism

    DEFF Research Database (Denmark)

    Smith, Anders; Nielsen, Kaspar Kirstein; Christensen, Dennis

    2010-01-01

    The effect of demagnetization on the magnetic properties of a rectangular ferromagnetic prism under non-uniform conditions is investigated. A numerical model for solving the spatially varying internal magnetic field is developed, validated and applied to relevant cases. The demagnetizing field...... is solved by an analytical calculation and the coupling between applied field, the demagnetization tensor field and spatially varying temperature is solved through iteration. We show that the demagnetizing field is of great importance in many cases and that it is necessary to take into account the non...

  11. Hydrodynamic characteristics of steady magnetic fluid flow in a straight tube by taking into account the non-uniform distribution of mass concentration

    International Nuclear Information System (INIS)

    Shuchi, S.; Shimada, K.; Kamiyama, S.; Yamaguchi, H.

    2002-01-01

    We clarify numerically the wall friction coefficient, the distributions of velocity and shear rate, and the number of aggregated particles on steady magnetic fluid flow in a straight tube by taking into account the non-uniform distribution of mass concentration (DMC). Also the effect of DMC is clarified under the uniform and non-uniform transverse steady magnetic field. In comparison with the published data, the numerical results show good agreement with the experimental data

  12. Methanol and ethanol vapor conversion in gas discharge with strongly non-uniform distribution of electric field on atmospheric pressure

    International Nuclear Information System (INIS)

    Golota, V.I.; Zavada, L.M.; Kotyukov, O.V.; Kudin, D.V.; Rodionov, S.V.; Pis'menetskoj, A.S.; Dotsenko, Yu.V.

    2010-01-01

    The barrierless gas discharge of negative polarity with strongly non-uniform distribution of electrical field in the methanol and ethanol vapour was studied. It is shown that level of methanol and ethanol conversion depended from power consumed by the discharge and exposition time for gas mixture in discharge zone. The condition for deep conversion of the methanol and ethanol vapours were determined. The water and carbon dioxide are the end products for the methanol and ethanol conversion. Formaldehyde and formic acid are the intermediates products in the conversion of methanol. And ethanol has a number of different compounds, including acetic acid, acetaldehyde, etc.

  13. Non-uniform current distribution in a force-cooled superconductor under changing magnetic field

    International Nuclear Information System (INIS)

    Koizumi, Norikiyo

    2000-02-01

    Strands in a large current force-cooled superconductor, referred to a CICC (cable-in-conduit conductor) hereafter, are coated with formvar (insulated layer) or chrome plating (high resistive layer) to reduce coupling current loss due to magnetic field variation. The author first carried out an experiment of the large superconducting coil consisting of such CICCs for demonstration of their applicability to a large superconducting coil. These CICCs exhibited instability, i.e. the normal zone propagation with thermal runaway (quench), at 1/20 and 1/5 of the expected conductor critical currents, respectively. The author constructed the database of this instability and studies its reason through experimental and theoretical investigations and then finds such instability is caused as a result of non-uniform current distribution in the conductor. Joule heating loss at electrical connections at the ends of the conductor should be small. Therefore, the strands in the CICC are electrically connected from each other with low resistance there. Circulation current is induced in the loop composed of the strands electrically connected at the ends of the conductor if its leakage magnetic flux is not completely vanished. The non-uniform current distribution is caused as a result of superimposition of the circulation and transport currents. The strand carrying large current becomes the normal state when it reaches or approaches to its critical current. Thus, the strands are twisted in order to vanish the leakage magnetic flux. The instability due to the current imbalance was not observed in the middle-scale coil (an element coil, such as a single double-pancake, of a large superconducting coil) consisting of the conductor in which the formvar-coated strands were twisted as above-mentioned. Consequently, it was believed that the leakage magnetic flux could be vanished by the normal twisting. However, the magnetic field increases in a large coil as a result of piling element coils

  14. Strain distributions in nano-onions with uniform and non-uniform compositions

    International Nuclear Information System (INIS)

    Duan, H L; Karihaloo, B L; Wang, J; Yi, X

    2006-01-01

    Nano-onions are ellipsoidal or spherical particles consisting of a core surrounded by concentric shells of nanometre size. Nano-onions produced by self-assembly and colloidal techniques have different structures and compositions, and thus differ in the state of strains. The mismatch of the thermal expansion coefficients and lattice constants between neighbouring shells induces stress/strain fields in the core and shells, which in turn affect their physical/mechanical properties and/or the properties of the composites containing them. In this paper, the strains in embedded and free-standing nano-onions with uniform and non-uniform compositions are studied in detail. It is found that the strains in the nano-onions can be modified by adjusting their compositions and structures. The results are useful for the band structure engineering of semiconductor nano-onions

  15. Investigation of Non-Uniform Rust Distribution and Its Effects on Corrosion Induced Cracking in Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Sutrisno Wahyuniarsih

    2017-01-01

    Full Text Available Uniform corrosion still widely used by a lot of researchers and engineers to analyze the corrosion induced cracking. However, in practice, corrosion process occurred non-uniformly. The part nearest to the exposed surface is more likely to have faster corrosion initiation compared with other regions. This research is mainly focused on investigating the effect of non-uniform rust distribution to cover cracking in reinforced concrete. An experimental test performed using accelerated corrosion test by using 5% NaCl solution and applied a constant electric current to the concrete samples. The rust distribution and measurement were observed by using a digital microscope. Based on the experimental result, it was found that the rust was distributed in a non-uniform pattern. As a result, the cracks also formed non-uniformly along the perimeter of steel bar. At the last part of this paper, a simulation result of concrete cracking induced by non-uniform corrosion is presented. The result compared with a simulation using uniform corrosion assumption to investigate the damage pattern of each model. The simulation result reveals stress evolution due to rust expansion which leads to concrete cracking. Furthermore, a comparison of stresses induced by non-uniform corrosion and uniform corrosion indicates that non-uniform corrosion could lead to earlier damage to the structure which is specified by the formation and propagation of the crack.

  16. A method for real time detecting of non-uniform magnetic field

    Science.gov (United States)

    Marusenkov, Andriy

    2015-04-01

    The principle of measuring magnetic signatures for observing diverse objects is widely used in Near Surface work (unexploded ordnance (UXO); engineering & environmental; archaeology) and security and vehicle detection systems as well. As a rule, the magnitude of the signals to be measured is much lower than that of the quasi-uniform Earth magnetic field. Usually magnetometers for these purposes contain two or more spatially separated sensors to estimate the full tensor gradient of the magnetic field or, more frequently, only partial gradient components. The both types (scalar and vector) of magnetic sensors could be used. The identity of the scale factors and proper alignment of the sensitivity axes of the vector sensors are very important for deep suppression of the ambient field and detection of weak target signals. As a rule, the periodical calibration procedure is used to keep matching sensors' parameters as close as possible. In the present report we propose the technique for detection magnetic anomalies, which is almost insensitive to imperfect matching of the sensors. This method based on the idea that the difference signals between two sensors are considerably different when the instrument is rotated or moved in uniform and non-uniform fields. Due to the misfit of calibration parameters the difference signal observed at the rotation in the uniform field is similar to the total signal - the sum of the signals of both sensors. Zero change of the difference and total signals is expected, if the instrument moves in the uniform field along a straight line. In contrast, the same move in the non-uniform field produces some response of each of the sensors. In case one measures dB/dx and moves along x direction, the sensors signals is shifted in time with the lag proportional to the distance between sensors and the speed of move. It means that the difference signal looks like derivative of the total signal at move in the non-uniform field. So, using quite simple

  17. Influence of Non-Uniform Magnetic Field on Quantum Teleportation in Heisenberg XY Model

    Institute of Scientific and Technical Information of China (English)

    SHAO Bin; YANG Tie-jian; ZHAO Yue-hong; ZOU Jian

    2007-01-01

    By considering the intrinsic decoherence, the validity of quantum teleportation of a two-qubit 1D Heisenberg XY chain in a non-uniform external magnetic field is studied. The fidelity as the measurement of a possible quantum teleportation is calculated and the effects of the non-uniform magnetic field and the intrinsic decoherence are discussed. It is found that anti-parallel magnetic field is more favorable for teleportation and the fidelity is suppressed by the intrinsic decoherence.

  18. Tumour control probability (TCP) for non-uniform activity distribution in radionuclide therapy

    International Nuclear Information System (INIS)

    Uusijaervi, Helena; Bernhardt, Peter; Forssell-Aronsson, Eva

    2008-01-01

    Non-uniform radionuclide distribution in tumours will lead to a non-uniform absorbed dose. The aim of this study was to investigate how tumour control probability (TCP) depends on the radionuclide distribution in the tumour, both macroscopically and at the subcellular level. The absorbed dose in the cell nuclei of tumours was calculated for 90 Y, 177 Lu, 103m Rh and 211 At. The radionuclides were uniformly distributed within the subcellular compartment and they were uniformly, normally or log-normally distributed among the cells in the tumour. When all cells contain the same amount of activity, the cumulated activities required for TCP = 0.99 (A-tilde TCP=0.99 ) were 1.5-2 and 2-3 times higher when the activity was distributed on the cell membrane compared to in the cell nucleus for 103m Rh and 211 At, respectively. TCP for 90 Y was not affected by different radionuclide distributions, whereas for 177 Lu, it was slightly affected when the radionuclide was in the nucleus. TCP for 103m Rh and 211 At were affected by different radionuclide distributions to a great extent when the radionuclides were in the cell nucleus and to lesser extents when the radionuclides were distributed on the cell membrane or in the cytoplasm. When the activity was distributed in the nucleus, A-tilde TCP=0.99 increased when the activity distribution became more heterogeneous for 103m Rh and 211 At, and the increase was large when the activity was normally distributed compared to log-normally distributed. When the activity was distributed on the cell membrane, A-tilde TCP=0.99 was not affected for 103m Rh and 211 At when the activity distribution became more heterogeneous. A-tilde TCP=0.99 for 90 Y and 177 Lu were not affected by different activity distributions, neither macroscopic nor subcellular

  19. Numerical research on natural convection in molten salt reactor with non-uniformly distributed volumetric heat generation

    International Nuclear Information System (INIS)

    Qian Libo; Qiu Suizheng; Zhang Dalin; Su Guanghui; Tian Wenxi

    2010-01-01

    Molten salt reactor is one of the six Generation IV systems capable of breeding and transmutation of actinides and long-lived fission products, which uses the liquid molten salt as the fuel solvent, coolant and heat generation simultaneously. The present work presents a numerical investigation on natural convection with non-uniform heat generation through which the heat generated by the fluid fuel is removed out of the core region when the reactor is under post-accident condition or zero-power condition. The two-group neutron diffusion equation is applied to calculated neutron flux distribution, which leads to non-uniform heat generation. The SIMPLER algorithm is used to calculate natural convective heat transfer rate with isothermal or adiabatic rigid walls. These two models are coupled through the temperature field and heat sources. The peculiarities of natural convection with non-uniform heat generation are investigated in a range of Ra numbers (10 3 ∼ 10 7 ) for the laminar regime of fluid motion. In addition, the numerical results are also compared with those containing uniform heat generation.

  20. Smoothing and instability with magnetic field in a non-uniformly laser-irradiated planar target

    International Nuclear Information System (INIS)

    Bell, A.R.; Epperlein, E.M.

    1986-01-01

    Calculations are presented of the magneto-hydrodynamic response of a planar target to non-uniformities in energy deposition by a laser. The amplitude of the non-uniformities are assumed small and the equations are linearised in small perturbations about the solution for steady planar ablation driven by uniform laser energy deposition. The grad(n)xgrad(T) magnetic field source is included, along with Nernst convection and the Righi-Leduc heat flow. The magnetic field is shown to give a small increase in smoothing. A source term for magnetic field is included to simulate the effects of the Weibel instability. The instability is not strong enough to overcome the smoothing processes under the present assumptions. (author)

  1. Ideal flood field images for SPECT uniformity correction

    International Nuclear Information System (INIS)

    Oppenheim, B.E.; Appledorn, C.R.

    1984-01-01

    Since as little as 2.5% camera non-uniformity can cause disturbing artifacts in SPECT imaging, the ideal flood field images for uniformity correction would be made with the collimator in place using a perfectly uniform sheet source. While such a source is not realizable the equivalent images can be generated by mapping the activity distribution of a Co-57 sheet source and correcting subsequent images of the source with this mapping. Mapping is accomplished by analyzing equal-time images of the source made in multiple precisely determined positions. The ratio of counts detected in the same region of two images is a measure of the ratio of the activities of the two portions of the source imaged in that region. The activity distribution in the sheet source is determined from a set of such ratios. The more source positions imaged in a given time, the more accurate the source mapping, according to results of a computer simulation. A 1.9 mCi Co-57 sheet source was shifted by 12 mm increments along the horizontal and vertical axis of the camera face to 9 positions on each axis. The source was imaged for 20 min in each position and 214 million total counts were accumulated. The activity distribution of the source, relative to the center pixel, was determined for a 31 x 31 array. The integral uniformity was found to be 2.8%. The RMS error for such a mapping was determined by computer simulation to be 0.46%. The activity distribution was used to correct a high count flood field image for non-uniformities attributable to the Co-57 source. Such a corrected image represents camera plus collimator response to an almost perfectly uniform sheet source

  2. Quasiparticles in non-uniformly magnetized plasma

    International Nuclear Information System (INIS)

    Sosenko, P.P.

    1994-01-01

    A quasiparticle concept is generalized for the case of non-uniformly magnetized plasma. Exact and reduced continuity equations for the microscopic density in the quasiparticle phase space are derived, and the nature of quasiparticles is analyzed. The theory is developed for the general case of relativistic particles in electromagnetic fields, besides non-uniform but stationary magnetic fields. Effects of non-stationary magnetic fields are briefly investigated also. 26 refs

  3. Effect of non-uniform surface resistance on the quality factor of superconducting niobium cavity

    Science.gov (United States)

    Tan, Weiwei; Lu, Xiangyang; Yang, Ziqin; Zhao, Jifei; Yang, Deyu; Yang, Yujia

    2016-08-01

    The formula Rs = G /Q0 is commonly used in the calculation of the surface resistance of radio frequency niobium superconducting cavities. The applying of such equation is under the assumption that surface resistance is consistent over the cavity. However, the distribution of the magnetic field varies over the cavity. The magnetic field in the equator is much higher than that in the iris. According to Thermal Feedback Theory, it leads non-uniform distribution of the density of heat flux, which results in a different temperature distribution along the cavity inter surface. The BCS surface resistance, which depends largely on the temperature, is different in each local inner surface. In this paper, the effect of surface non-uniform resistance on the quality factor has been studied, through the calculation of Q0 in the original definition of it. The results show that it is necessary to consider the non-uniform distribution of magnetic field when the accelerating field is above 20 MV/m for TESLA cavities. Also, the effect of inhomogeneity of residual resistance on the quality factor is discussed. Its distribution barely affects the quality factor.

  4. An Ad Hoc Adaptive Hashing Technique forNon-Uniformly Distributed IP Address Lookup in Computer Networks

    Directory of Open Access Journals (Sweden)

    Christopher Martinez

    2007-02-01

    Full Text Available Hashing algorithms long have been widely adopted to design a fast address look-up process which involves a search through a large database to find a record associated with a given key. Hashing algorithms involve transforming a key inside each target data to a hash value hoping that the hashing would render the database a uniform distribution with respect to this new hash value. The close the final distribution is to uniform, the less search time would be required when a query is made. When the database is already key-wise uniformly distributed, any regular hashing algorithm, such as bit-extraction, bit-group XOR, etc., would easily lead to a statistically perfect uniform distribution after the hashing. On the other hand, if records in the database are instead not uniformly distributed as in almost all known practical applications, then even different regular hash functions would lead to very different performance. When the target database has a key with a highly skewed distributed value, performance delivered by regular hashing algorithms usually becomes far from desirable. This paper aims at designing a hashing algorithm to achieve the highest probability in leading to a uniformly distributed hash result from a non-uniformly distributed database. An analytical pre-process on the original database is first performed to extract critical information that would significantly benefit the design of a better hashing algorithm. This process includes sorting on the bits of the key to prioritize the use of them in the XOR hashing sequence, or in simple bit extraction, or even a combination of both. Such an ad hoc hash design is critical to adapting to all real-time situations when there exists a changing (and/or expanding database with an irregular non-uniform distribution. Significant improvement from simulation results is obtained in randomly generated data as well as real data.

  5. On the burnout in annular channels at non-uniform heat release distribution in length

    International Nuclear Information System (INIS)

    Ornatskij, A.P.; Chernobaj, V.A.; Vasil'ev, A.F.; Struts, G.V.

    1982-01-01

    The effect of axial heat release non-uniformity on the conditions of the burnout in annular channels is investigated. The investigation is carried out in annular channels with different laws of heat flux density distribution by channel length. The heat release non-uniformity coefficient was varied from 4.4 to 10, the pressure from 9.8 to 17.6 MPa, mass rate from 500 to 1700 kg (m 2 xS), liquid temperature (chemically desalted water) at the channel inlet constituted 30-300 deg C. The experiments have been performed at the test bench with a closed circulation circuit. The data obtained testify to the fact that under non-uniform heat release the influence of main operating parameters on the value of critical power is of the same character as under uniform heat release. The character of wall temperature variation by channel length before the burnout is determined by the form of heat supply temperature profile. The temperature maximum is observed in the region lying behind the cross section with maximum heat flux. The conclusion is drawn that the dominant influence on the position of the cross section in which the burnout arises is exerted by the form of heat flux density distribution by length. Independently of this distribution form the burnout developes when the vapour content near the wall reaches a limiting value

  6. Centrifugal pumping during Czochralski silicon growth with a strong, non-uniform, axisymmetric magnetic field

    Science.gov (United States)

    Khine, Y. Y.; Walker, J. S.

    1996-08-01

    Centrifugal pumping flows are produced in the melt by the rotations of crystal and crucible during the Czochralski growth of silicon crystals. This paper treats the centrifugal pumping effects with a steady, strong, non-uniform axisymmetric magnetic field. We consider a family of magnetic fields ranging from a uniform axial field to a "cusp" field, which has a purely radial field at the crystal-melt interface and free surface. We present the numerical solutions for the centrifugal pumping flows as the magnetic field is changed continuously from a uniform axial field to a cusp one, and for arbitrary Hartmann number. Since the perfect alignment between the local magnetic field vector and the crystal-melt interface or free surface is not likely, we also investigate the effects of a slight misalignment.

  7. Numerical analysis of blood flow in realistic arteries subjected to strong non-uniform magnetic fields

    International Nuclear Information System (INIS)

    Kenjeres, Sasa

    2008-01-01

    The paper reports on a comprehensive mathematical model for simulations of blood flow under the presence of strong non-uniform magnetic fields. The model consists of a set of Navier-Stokes equations accounting for the Lorentz and magnetisation forces, and a simplified set of Maxwell's equations (Biot-Savart/Ampere's law) for treating the imposed magnetic fields. The relevant hydrodynamic and electromagnetic properties of human blood were taken from the literature. The model is then validated for different test cases ranging from a simple cylindrical geometry to real-life right-coronary arteries in humans. The time-dependency of the wall-shear-stress for different stenosis growth rates and the effects of the imposed strong non-uniform magnetic fields on the blood flow pattern are presented and analysed. It is concluded that an imposed non-uniform magnetic field can create significant changes in the secondary flow patterns, thus making it possible to use this technique for optimisations of targeted drug delivery

  8. Modelling non-uniform strain distributions in aerospace composites using fibre Bragg gratings

    NARCIS (Netherlands)

    Rajabzadehdizaji, Aydin; Groves, R.M.; Hendriks, R.C.; Heusdens, R.; Chung, Y.; Jin, W.; Lee, B.; Canning, J.; Nakamura, K.; Yuan, L.

    2017-01-01

    In this paper the behaviour of fibre Bragg grating (FBG) sensors under non-uniform strain distributions was analysed. Using the fundamental matrix approach, the length of the FBG sensor was discretised, with each segment undergoing different strain values. FBG sensors that are embedded inside

  9. Skin carcinogenesis following uniform and non-uniform β irradiation

    International Nuclear Information System (INIS)

    Charles, M.W.; Williams, J.P.; Coggle, J.E.

    1989-01-01

    Where workers or the general public may be exposed to ionising radiation, the irradiation is rarely uniform. The risk figures and dose limits recommended by the International Commission on Radiological Protection (ICRP) are based largely on clinical and epidemiological studies of reasonably uniform irradiated organs. The paucity of clinical or experimental data for highly non-uniform exposures has prevented the ICRP from providing adequate recommendations. This weakness has led on a number of occasions to the postulate that highly non-uniform exposures of organs could be 100,000 times more carcinogenic than ICRP risk figures would predict. This so-called ''hot-particle hypothesis'' found little support among reputable radiobiologists, but could not be clearly and definitively refuted on the basis of experiment. An experiment, based on skin tumour induction in mouse skin, is described which was developed to test the hypothesis. The skin of 1200 SAS/4 male mice has been exposed to a range of uniform and non-uniform sources of the β emitter 170 Tm (E max ∼ 1 MeV). Non-uniform exposures were produced using arrays of 32 or 8 2-mm diameter sources distributed over the same 8-cm 2 area as a uniform control source. Average skin doses varied from 2-100 Gy. The results for the non-uniform sources show a 30% reduction in tumour incidence by the 32-point array at the lower mean doses compared with the response from uniform sources. The eight-point array showed an order-of-magnitude reduction in tumour incidence compared to uniform irradiation at low doses. These results, in direct contradiction to the ''hot particle hypothesis'', indicate that non-uniform exposures produce significantly fewer tumours than uniform exposures. (author)

  10. New method for solving inductive electric fields in the non-uniformly conducting ionosphere

    Directory of Open Access Journals (Sweden)

    H. Vanhamäki

    2006-10-01

    Full Text Available We present a new calculation method for solving inductive electric fields in the ionosphere. The time series of the potential part of the ionospheric electric field, together with the Hall and Pedersen conductances serves as the input to this method. The output is the time series of the induced rotational part of the ionospheric electric field. The calculation method works in the time-domain and can be used with non-uniform, time-dependent conductances. In addition, no particular symmetry requirements are imposed on the input potential electric field. The presented method makes use of special non-local vector basis functions called the Cartesian Elementary Current Systems (CECS. This vector basis offers a convenient way of representing curl-free and divergence-free parts of 2-dimensional vector fields and makes it possible to solve the induction problem using simple linear algebra. The new calculation method is validated by comparing it with previously published results for Alfvén wave reflection from a uniformly conducting ionosphere.

  11. New method for solving inductive electric fields in the non-uniformly conducting ionosphere

    Science.gov (United States)

    Vanhamäki, H.; Amm, O.; Viljanen, A.

    2006-10-01

    We present a new calculation method for solving inductive electric fields in the ionosphere. The time series of the potential part of the ionospheric electric field, together with the Hall and Pedersen conductances serves as the input to this method. The output is the time series of the induced rotational part of the ionospheric electric field. The calculation method works in the time-domain and can be used with non-uniform, time-dependent conductances. In addition, no particular symmetry requirements are imposed on the input potential electric field. The presented method makes use of special non-local vector basis functions called the Cartesian Elementary Current Systems (CECS). This vector basis offers a convenient way of representing curl-free and divergence-free parts of 2-dimensional vector fields and makes it possible to solve the induction problem using simple linear algebra. The new calculation method is validated by comparing it with previously published results for Alfvén wave reflection from a uniformly conducting ionosphere.

  12. Buoyant convection during Czochralski silicon growth with a strong, non-uniform, axisymmetric magnetic field

    Science.gov (United States)

    Khine, Y. Y.; Walker, J. S.

    1995-02-01

    This paper treats the buoyant convection during the Czochralski growth of silicon crystals with a steady, strong, non-uniform, axisymmetric magnetic field. We consider a family of magnetic fields which includes a uniform axial magnetic field and a "cusp" field which is produced by identical solenoids placed symmetrically above and below the plane of the crystal-melt interface and free surface. We investigate the evolution of the buoyant convection as the magnetic field is changed continuously from a uniform axial field to a cusp field, with a constant value of the root-mean-squared magnetic flux density in the melt. We also investigate changes as the magnetic flux density is increased. While the cusp field appears very promising, perfect alignment between the local magnetic field vector and the crystal-melt interface or free surface is not possible, so the effects of a slight misalignment are also investigated.

  13. Image restoration from non-uniform magnetic field influence for direct Fourier NMR imaging

    International Nuclear Information System (INIS)

    Sekihara, K.; Kuroda, M.; Kohno, H.

    1984-01-01

    A new technique is proposed for NMR image restoration from the influence of main magnetic field non-uniformities. This technique is applicable to direct Fourier NMR imaging. The mathematical basis and details of this technique are fully described. Modification to include image restoration from non-linear field gradient influence is also presented. Computer simulation demonstrates the effectiveness of this technique for both Fourier zeugmatography and spin-warp imaging. (author)

  14. Non-uniform Solar Temperature Field on Large Aperture, Fully-Steerable Telescope Structure

    Science.gov (United States)

    Liu, Yan

    2016-09-01

    In this study, a 110-m fully steerable radio telescope was used as an analysis platform and the integral parametric finite element model of the antenna structure was built in the ANSYS thermal analysis module. The boundary conditions of periodic air temperature, solar radiation, long-wave radiation shadows of the surrounding environment, etc. were computed at 30 min intervals under a cloudless sky on a summer day, i.e., worstcase climate conditions. The transient structural temperatures were then analyzed under a period of several days of sunshine with a rational initial structural temperature distribution until the whole set of structural temperatures converged to the results obtained the day before. The non-uniform temperature field distribution of the entire structure and the main reflector surface RMS were acquired according to changes in pitch and azimuth angle over the observation period. Variations in the solar cooker effect over time and spatial distributions in the secondary reflector were observed to elucidate the mechanism of the effect. The results presented here not only provide valuable realtime data for the design, construction, sensor arrangement and thermal deformation control of actuators but also provide a troubleshooting reference for existing actuators.

  15. The importance of non-uniform dose-distribution in an organ

    International Nuclear Information System (INIS)

    Richmond, C.R.

    1975-01-01

    The recent revival of interest in the 'hot particle' problem, especially as regards particulate plutonium and other actinide elements in the lung, stimulated the preparation of this paper. Non-uniformity of dose-distribution has been of concern to standards-setting bodies and other groups such as the National Academy of Sciences and to health protectionists for many years. This paper reviews data from animal experiments that are used by some to implicate particulate plutonium as being especially hazardous to man. Other relevant biological data are also discussed. (author)

  16. Novel attempt to create uniform magnetic-field space generated by face-to-face settled HTS bulk magnets

    International Nuclear Information System (INIS)

    Oka, Tetsuo; Ichiju, Kana; Higa, Kazuya; Fukui, Satoshi; Ogawa, Jun; Sato, Takao; Yokoyama, Kazuya; Nakamura, Takashi

    2017-01-01

    Various experimental attempts have been made to obtain a uniform magnetic field in the space between face-to-face HTS bulk magnets that could possibly be utilized as NMR magnets. In general, the magnetic fields emitted from the magnetic pole surfaces containing HTS bulk magnets are characterized as non-uniform field distributions. Since the NMR magnets require highly uniform magnetic-field spaces, it has been assumed to be difficult to form uniform magnetic-field spaces between magnetic poles placed face-to-face. The authors modified the shapes of the magnetic-field distribution from convex to concave by attaching ferromagnetic iron plates to the pole surfaces. The magnets were then set face-to-face with various gaps of 30-70 mm, and the experimental data on magnetic-field uniformity was precisely measured in the space. In order to detect the NMR signals, the target performance for uniformity was set as 1,500 ppm throughout the 4-mm span on the x-axis, which is equivalent to performance in the past when the world's first detection of NMR signals was observed in the bore of hollow-type HTS bulk magnets. When we combined the concave and convex field distributions to compensate the uneven field distributions, the data of the best uniformity reached 358 ppm and 493 ppm in the 30 mm and 50 mm gaps, respectively, which exceeded the target value for the purpose of detecting the NMR signals within the space. Furthermore, it was shown that the field distributions change from concave to convex shape without any change at 1.1 T in the range from 7 to 11 mm in the 30-mm gap, indicating that the distributions are uniform. This suggests the possibility that the uniform magnetic-field space between the HTS bulk magnets set face-to-face expands. (author)

  17. Magnetic fluid bridge in a non-uniform magnetic field

    International Nuclear Information System (INIS)

    Pelevina, D.A.; Naletova, V.A.; Turkov, V.A.

    2017-01-01

    The shape of a magnetic fluid bridge between a horizontal ferrite rod of circular cross-section and a horizontal plate above the rod in a vertical applied uniform magnetic field is studied. Various static shapes of the bridges are obtained theoretically and experimentally for the same magnetic field value. Abrupt changes and the hysteresis of the bridge shape in alternating magnetic fields are observed experimentally. - Highlights: • Magnetic fluid bridge between rod and horizontal plate in magnetic field is studied. • Magnetic field is created by a ferrite rod in a uniform vertical magnetic field. • Various static bridge shapes for fixed field are obtained in theory and experiment. • A good agreement of experimental and theoretical results is obtained. • Hysteresis of the bridge shape in alternating field is observed experimentally.

  18. Magnetic fluid bridge in a non-uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Pelevina, D.A., E-mail: pelevina.daria@gmail.com; Naletova, V.A.; Turkov, V.A.

    2017-06-01

    The shape of a magnetic fluid bridge between a horizontal ferrite rod of circular cross-section and a horizontal plate above the rod in a vertical applied uniform magnetic field is studied. Various static shapes of the bridges are obtained theoretically and experimentally for the same magnetic field value. Abrupt changes and the hysteresis of the bridge shape in alternating magnetic fields are observed experimentally. - Highlights: • Magnetic fluid bridge between rod and horizontal plate in magnetic field is studied. • Magnetic field is created by a ferrite rod in a uniform vertical magnetic field. • Various static bridge shapes for fixed field are obtained in theory and experiment. • A good agreement of experimental and theoretical results is obtained. • Hysteresis of the bridge shape in alternating field is observed experimentally.

  19. One-step fabrication of nanostructure-covered microstructures using selective aluminum anodization based on non-uniform electric field

    Science.gov (United States)

    Park, Yong Min; Kim, Byeong Hee; Seo, Young Ho

    2016-06-01

    This paper presents a selective aluminum anodization technique for the fabrication of microstructures covered by nanoscale dome structures. It is possible to fabricate bulging microstructures, utilizing the different growth rates of anodic aluminum oxide in non-uniform electric fields, because the growth rate of anodic aluminum oxide depends on the intensity of electric field, or current density. After anodizing under a non-uniform electric field, bulging microstructures covered by nanostructures were fabricated by removing the residual aluminum layer. The non-uniform electric field induced by insulative micropatterns was estimated by computational simulations and verified experimentally. Utilizing computational simulations, the intensity profile of the electric field was calculated according to the ratio of height and width of the insulative micropatterns. To compare computational simulation results and experimental results, insulative micropatterns were fabricated using SU-8 photoresist. The results verified that the shape of the bottom topology of anodic alumina was strongly dependent on the intensity profile of the applied electric field, or current density. The one-step fabrication of nanostructure-covered microstructures can be applied to various fields, such as nano-biochip and nano-optics, owing to its simplicity and cost effectiveness.

  20. Analysis of Causes of Non-Uniform Flow Distribution in Manifold Systems with Variable Flow Rate along Length

    Science.gov (United States)

    Zemlyanaya, N. V.; Gulyakin, A. V.

    2017-11-01

    The uniformity of flow distribution in perforated manifolds is a relevant task. The efficiency of water supply, sewerage and perflation systems is determined by hydraulics of the flow with a variable mass. The extensive study of versatile available information showed that achieving a uniform flow distribution through all of the outlets is almost impossible. The analysis of the studies conducted by other authors and our numerical experiments performed with the help of the software package ANSYS 16.1 were made in this work. The results allowed us to formulate the main causes of non-uniform flow distribution. We decided to suggest a hypothesis to explain the static pressure rise problem at the end of a perforated manifold.

  1. Impact of uniform electrode current distribution on ETF

    Science.gov (United States)

    Bents, D. J.

    1982-01-01

    The design impacts on the ETF electrode consolidation network associated with uniform channel electrode current distribution are examined and the alternate consolidation design which occur are presented compared to the baseline (non-uniform current) design with respect to performance, and hardware requirements. A rational basis is given for comparing the requirements for the different designs and the savings that result from uniform current distribution. Performance and cost impacts upon the combined cycle plant are discussed.

  2. Two-dimensional hydrodynamics of uniform ion plasma in electrostatic field

    International Nuclear Information System (INIS)

    Mahdieh, M. H.; Gavili, A.

    2005-01-01

    Two-dimensional hydrodynamics of ion extraction from uniform quasi-neutral plasma, in electrostatic field has been simulated numerically. Experimentally, tunable pulsed lasers produce non-uniform plasma through stepwise photo-excitation and photo-ionization or multi-photo-ionization processes. Poisson's equation was solved simultaneously with the equations of mass, and momentum, assuming the Maxwell-Boltzmann distribution for electrons. In the calculation, the initial density profile at the boundaries has been assumed to be very steep for the ion plasma. In these calculations dynamics of electric potential and the ions density were assessed. The ion extraction time was also estimated from the calculation. The knowledge of spatial distribution of the ions across the cathode is very important for the practical purposes. In this simulation, the spatial distribution of the ion current density across the cathode as well as its temporal distribution was calculated

  3. Planned studies of charge collection in non-uniformly irradiated Si and GaAs detectors

    International Nuclear Information System (INIS)

    Rosenfeld, A.; Reinhard, M.; Carolan, M.; Kaplan, G.; Lerch, M.; Alexiev, D.

    1995-01-01

    The aim of this project is to study the time and amplitude characteristics of silicon ion-implanted detectors non-uniformly irradiated with fast neutrons in order to predict their radiation behaviour in the LHC and space. It is expected in such detectors increases of the charge deficit due to trapping by large scale traps and transient time increases due to the reduction of the mobility. The theoretical model will be modified to describe the charge kinetics in the electrical field of the detector created by a non uniform space charge distribution. Experimental confirmation techniques are needed to develop non uniform predictable damage of silicon detectors using fast neutron sources (accelerators, reactors) and to study peculiarities of the charge transport in different parts of the detector. In parallel to experimental research will be started the theoretical development of the charge transport model for non-uniform distribution of space charge in the depletion layer (Neff). The model will include the linear distribution of Neff(y) along the detector as well as the change of sign of Neff (conversion from n to p type of silicon) inside the detector

  4. A poloidal non-uniformity of the collisionless parallel current in a tokamak plasma

    Energy Technology Data Exchange (ETDEWEB)

    Romannikov, A.; Fenzi-Bonizec, C

    2005-07-01

    The collisionless distortion of the ion (electron) distribution function at certain points on a magnetic surface is studied in the framework of a simple model of a large aspect ratio tokamak plasma. The flow velocity driven by this distortion is calculated. The possibility of an additional non-uniform collisionless parallel current density on a magnetic surface, other than the known neo-classical non-uniformity is shown. The difference between the parallel current density on the low and high field side of a magnetic surface is close to the neoclassical bootstrap current density. The first Tore-Supra experimental test indicates the possibility of the poloidal non-uniformity of the parallel current density. (authors)

  5. A stability criterion for HNFDE with non-uniform delays

    International Nuclear Information System (INIS)

    Liu Xingwen; Zhong Shouming; Zhang Fengli

    2005-01-01

    Stability of functional differential equations (FDE) is an increasingly important problem in both science and engineering. Delays, whether uniform or non-uniform, play an important role in the dynamics of a system. Since non-uniform delay is more general and less focused than uniform delay, this paper concentrates on the stability of high-order neutral functional differential equations (HNFDE) with non-uniform delay, and proposes a sufficient condition for it. This result may be widely helpful, thanks to the frequent emergence of a HNFDE with non-uniform delay in various fields. Its effectiveness is illustrated by some examples

  6. Concentration polarization effects on the macromolecular transport in the presence of non-uniform magnetic field: A numerical study using a lumen-wall model

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadpourfard, M., E-mail: Mohammadpour@azaruniv.edu [Department of Mechanical Engineering, Azarbaijan Shahid Madani University, Tabriz 53751-71379 (Iran, Islamic Republic of); Aminfar, H., E-mail: hh_aminfar@tabrizu.ac.ir [Faculty of Mechanical Engineering, University of Tabriz, Tabriz (Iran, Islamic Republic of); Khajeh, K., E-mail: khajeh.k.2005@gmail.com [Faculty of Mechanical Engineering, University of Tabriz, Tabriz (Iran, Islamic Republic of)

    2014-04-01

    In this paper, the concentration polarization phenomena in a two dimensional tube under steady state conditions containing ferrofluid (blood and 4 vol% Fe{sub 3}O{sub 4}) is reported in the presence of non-uniform magnetic field. Lumen-wall model has been used for solving the mass transport equation. Hemodynamics parameters such as flow rate, viscosity, wall shear stress (WSS) and the macromolecules surface concentration which accumulate on the blood vessel wall, influenced the formation and progression of atherosclerosis disease. Effective parameters on the low density lipoprotein (LDL) surface concentration (LSC) such as: the wall filtration velocity, inlet Reynolds number and WSS under applied non-uniform magnetic field have been examined. Numerical solution of governing equations of the flow field have been obtained by using the single-phase model and the control volume technique. Magnetic field is generated by an electric current going through a thin and straight wire oriented perpendicular to the tube. Results show WSS in the vicinity of magnetic field source increased and LSC decreased along the wall. - Highlights: • In this paper the concentration polarization phenomena of blood flow is reported in the presence of non-uniform magnetic field. • In presence of non-uniform magnetic field LSC will decrease along the wall due to the increasing the velocity gradients near the magnetic source. • When non-uniform magnetic field intensity increases, LSC along the wall becomes lower. • Non-uniform magnetic field can affects the flow more in low Reynolds numbers.

  7. Reactivity effect of non-uniformly distributed fuel in fuel solution systems

    International Nuclear Information System (INIS)

    Hirano, Yasushi; Yamane, Yoshihiro; Nishina, Kojiro; Mitsuhashi, Ishi.

    1991-01-01

    A numerical method to determine the optimal fuel distribution for minimum critical mass, or maximum k-effective, is developed using the Maximum Principle in order to evaluate the maximum effect of non-uniformly distributed fuel on reactivity. This algorithm maximizes the Hamiltonian directly by an iterative method under a certain constraint-the maintenance of criticality or total fuel mass. It ultimately reaches the same optimal state of a flattened fuel importance distribution as another algorithm by Dam based on perturbation theory. This method was applied to two kinds of spherical cores with water reflector in the simulating reprocessing facility. In the slightly-enriched uranyl nitrate solution core, the minimum critical mass decreased by less than 1% at the optimal moderation state. In the plutonium nitrate solution core, the k-effective increment amounted up to 4.3% Δk within the range of present study. (author)

  8. Effect of non-uniform mean flow field on acoustic propagation problems in computational aeroacoustics

    DEFF Research Database (Denmark)

    Si, Haiqing; Shen, Wen Zhong; Zhu, Wei Jun

    2013-01-01

    Acoustic propagation in the presence of a non-uniform mean flow is studied numerically by using two different acoustic propagating models, which solve linearized Euler equations (LEE) and acoustic perturbation equations (APE). As noise induced by turbulent flows often propagates from near field t...

  9. Downsampling Non-Uniformly Sampled Data

    Directory of Open Access Journals (Sweden)

    Fredrik Gustafsson

    2007-10-01

    Full Text Available Decimating a uniformly sampled signal a factor D involves low-pass antialias filtering with normalized cutoff frequency 1/D followed by picking out every Dth sample. Alternatively, decimation can be done in the frequency domain using the fast Fourier transform (FFT algorithm, after zero-padding the signal and truncating the FFT. We outline three approaches to decimate non-uniformly sampled signals, which are all based on interpolation. The interpolation is done in different domains, and the inter-sample behavior does not need to be known. The first one interpolates the signal to a uniformly sampling, after which standard decimation can be applied. The second one interpolates a continuous-time convolution integral, that implements the antialias filter, after which every Dth sample can be picked out. The third frequency domain approach computes an approximate Fourier transform, after which truncation and IFFT give the desired result. Simulations indicate that the second approach is particularly useful. A thorough analysis is therefore performed for this case, using the assumption that the non-uniformly distributed sampling instants are generated by a stochastic process.

  10. ELECTRONIC CIRCUIT BOARDS NON-UNIFORM COOLING SYSTEM MODEL

    Directory of Open Access Journals (Sweden)

    D. V. Yevdulov

    2016-01-01

    Full Text Available Abstract. The paper considers a mathematical model of non-uniform cooling of electronic circuit boards. The block diagram of the system implementing this approach, the method of calculation of the electronic board temperature field, as well as the principle of its thermal performance optimizing are presented. In the considered scheme the main heat elimination from electronic board is produced by the radiator system, and additional cooling of the most temperature-sensitive components is produced by thermoelectric batteries. Are given the two-dimensional temperature fields of the electronic board during its uniform and non-uniform cooling, is carried out their comparison. As follows from the calculations results, when using a uniform overall cooling of electronic unit there is a waste of energy for the cooling 0f electronic board parts which temperature is within acceptable temperature range without the cooling system. This approach leads to the increase in the cooling capacity of used thermoelectric batteries in comparison with the desired values. This largely reduces the efficiency of heat elimination system. The use for electronic boards cooling of non-uniform local heat elimination removes this disadvantage. The obtained dependences show that in this case, the energy required to create a given temperature is smaller than when using a common uniform cooling. In this approach the temperature field of the electronic board is more uniform and the cooling is more efficient. 

  11. Induced charge of spherical dust particle on plasma-facing wall in non-uniform electric field

    International Nuclear Information System (INIS)

    Tomita, Y.; Smirnov, R.; Zhu, S.

    2005-01-01

    Induced charge of a spherical dust particle on a plasma-facing wall is investigated analytically, where non-uniform electric field is applied externally. The one-dimensional non-uniform electrostatic potential is approximated by the polynomial of the normal coordinate toward the wall. The bipolar coordinate is introduced to solve the Laplace equation of the induced electrostatic potential. The boundary condition at the dust surface determines the unknown coefficients of the general solution of the Laplace equation for the induced potential. From the obtained potential the surface induced charge can be calculated. This result allows estimating the effect of the surrounding plasma, which shields the induced charge. (author)

  12. Size Distribution Imaging by Non-Uniform Oscillating-Gradient Spin Echo (NOGSE MRI.

    Directory of Open Access Journals (Sweden)

    Noam Shemesh

    Full Text Available Objects making up complex porous systems in Nature usually span a range of sizes. These size distributions play fundamental roles in defining the physicochemical, biophysical and physiological properties of a wide variety of systems - ranging from advanced catalytic materials to Central Nervous System diseases. Accurate and noninvasive measurements of size distributions in opaque, three-dimensional objects, have thus remained long-standing and important challenges. Herein we describe how a recently introduced diffusion-based magnetic resonance methodology, Non-Uniform-Oscillating-Gradient-Spin-Echo (NOGSE, can determine such distributions noninvasively. The method relies on its ability to probe confining lengths with a (length6 parametric sensitivity, in a constant-time, constant-number-of-gradients fashion; combined, these attributes provide sufficient sensitivity for characterizing the underlying distributions in μm-scaled cellular systems. Theoretical derivations and simulations are presented to verify NOGSE's ability to faithfully reconstruct size distributions through suitable modeling of their distribution parameters. Experiments in yeast cell suspensions - where the ground truth can be determined from ancillary microscopy - corroborate these trends experimentally. Finally, by appending to the NOGSE protocol an imaging acquisition, novel MRI maps of cellular size distributions were collected from a mouse brain. The ensuing micro-architectural contrasts successfully delineated distinctive hallmark anatomical sub-structures, in both white matter and gray matter tissues, in a non-invasive manner. Such findings highlight NOGSE's potential for characterizing aberrations in cellular size distributions upon disease, or during normal processes such as development.

  13. Influence of Non-uniform Temperature Field on Spectra of Fibre Bragg Grating

    International Nuclear Information System (INIS)

    Yan, Zhou; Xing-Fang, He; Xiao-Yong, Fang; Jie, Yuan; Li-Qun, Yin; Mao-Sheng, Cao

    2009-01-01

    We simulate the spectrum characteristics of fibre Bragg grating (FBG) with non-uniform temperature using the transmission matrix method, and the results are analysed. It is found that firstly the modulated coefficient of average refractive index is a very important parameter that influences the spectrum characteristic of the fibre Bragg grating, and secondly the spectrum curves are different in different temperature fields at the same parameter. Hence, we can determine the metrical temperature by analysing the spectrum of fibre Bragg grating

  14. Numerical analysis of blood flow in realistic arteries subjected to strong non-uniform magnetic fields

    NARCIS (Netherlands)

    Kenjeres, S.

    2008-01-01

    The paper reports on a comprehensive mathematical model for simulations of blood flow under the presence of strong non-uniform magnetic fields. The model consists of a set of Navier–Stokes equations accounting for the Lorentz and magnetisation forces, and a simplified set of Maxwell’s equations

  15. Impact of uniform electrode current distribution on ETF. [Engineering Test Facility MHD generator

    Science.gov (United States)

    Bents, D. J.

    1982-01-01

    A basic reason for the complexity and sheer volume of electrode consolidation hardware in the MHD ETF Powertrain system is the channel electrode current distribution, which is non-uniform. If the channel design is altered to provide uniform electrode current distribution, the amount of hardware required decreases considerably, but at the possible expense of degraded channel performance. This paper explains the design impacts on the ETF electrode consolidation network associated with uniform channel electrode current distribution, and presents the alternate consolidation designs which occur. They are compared to the baseline (non-uniform current) design with respect to performance, and hardware requirements. A rational basis is presented for comparing the requirements for the different designs and the savings that result from uniform current distribution. Performance and cost impacts upon the combined cycle plant are discussed.

  16. Modeling of a Pouch Lithium Ion Battery Using a Distributed Parameter Equivalent Circuit for Internal Non-Uniformity Analysis

    Directory of Open Access Journals (Sweden)

    Dafen Chen

    2016-10-01

    Full Text Available A battery model that has the capability of analyzing the internal non-uniformity of local state variables, including the state of charge (SOC, temperature and current density, is proposed in this paper. The model is built using a set of distributed parameter equivalent circuits. In order to validate the accuracy of the model, a customized battery with embedded T-type thermocouple sensors inside the battery is tested. The simulated temperature conforms well with the measured temperature at each test point, and the maximum difference is less than 1 °C. Then, the model is applied to analyze the evolution processes of local state variables’ distribution inside the battery during the discharge process. The simulation results demonstrate drastic distribution changes of the local state variables inside the battery during the discharge process. The internal non-uniformity is originally caused by the resistance of positive and negative foils, while also influenced by the change rate of open circuit voltage and the total resistance of the battery. Hence, the factors that affect the distribution of the local state variables are addressed.

  17. Electrical field excitation in non-uniform plasma by a modulated electron beam

    International Nuclear Information System (INIS)

    Anisimov, I.O.; Borisov, O.A.

    2000-01-01

    Excitation of electric fields due to a modulated electron beam in a warm non-uniform plasma is treated for weak beams in warm plasma. It is shown that the maximum electric field magnitude that is reached near the local plasma resonance point depends significantly on the direction of the electron stream motion. In collisional plasma the magnitude of the Langmuir wave that propagates to the subcritical plasma also depends on the direction of the electron stream motion. The motion of the modulated electron stream front results in beatings between oscillations on the modulation frequency and on the local electron plasma frequencies at the initial moment. Later these beatings damp in the supercritical plasma, whereas in the subcritical plasma they are transformed into spatial beatings between the field of the modulated electron stream and the excited Langmuir wave. (orig.)

  18. Bridge density functional approximation for non-uniform hard core repulsive Yukawa fluid

    International Nuclear Information System (INIS)

    Zhou Shiqi

    2008-01-01

    In this work, a bridge density functional approximation (BDFA) (J. Chem. Phys. 112, 8079 (2000)) for a non-uniform hard-sphere fluid is extended to a non-uniform hard-core repulsive Yukawa (HCRY) fluid. It is found that the choice of a bulk bridge functional approximation is crucial for both a uniform HCRY fluid and a non-uniform HCRY fluid. A new bridge functional approximation is proposed, which can accurately predict the radial distribution function of the bulk HCRY fluid. With the new bridge functional approximation and its associated bulk second order direct correlation function as input, the BDFA can be used to well calculate the density profile of the HCRY fluid subjected to the influence of varying external fields, and the theoretical predictions are in good agreement with the corresponding simulation data. The calculated results indicate that the present BDFA captures quantitatively the phenomena such as the coexistence of solid-like high density phase and low density gas phase, and the adsorption properties of the HCRY fluid, which qualitatively differ from those of the fluids combining both hard-core repulsion and an attractive tail. (condensed matter: structure, thermal and mechanical properties)

  19. THE MAGNETIC FIELD OF L1544. I. NEAR-INFRARED POLARIMETRY AND THE NON-UNIFORM ENVELOPE

    Energy Technology Data Exchange (ETDEWEB)

    Clemens, Dan P. [Institute for Astrophysical Research, Boston University, 725 Commonwealth Avenue, Boston, MA 02215 (United States); Tassis, K. [Department of Physics and ITCP, University of Crete, 71003, Heraklion (Greece); Goldsmith, Paul F., E-mail: clemens@bu.edu, E-mail: tassis@physics.uoc.gr, E-mail: paul.f.goldsmith@jpl.nasa.gov [Jet Propulsion Laboratory, M/S 169-504, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States)

    2016-12-20

    The magnetic field ( B -field) of the starless dark cloud L1544 has been studied using near-infrared (NIR) background starlight polarimetry (BSP) and archival data in order to characterize the properties of the plane-of-sky B -field. NIR linear polarization measurements of over 1700 stars were obtained in the H band and 201 of these were also measured in the K band. The NIR BSP properties are correlated with reddening, as traced using the Rayleigh–Jeans color excess ( H – M ) method, and with thermal dust emission from the L1544 cloud and envelope seen in Herschel maps. The NIR polarization position angles change at the location of the cloud and exhibit their lowest dispersion there, offering strong evidence that NIR polarization traces the plane-of-sky B -field of L1544. In this paper, the uniformity of the plane-of-sky B -field in the envelope region of L1544 is quantitatively assessed. This allows evaluation of the approach of assuming uniform field geometry when measuring relative mass-to-flux ratios in the cloud envelope and core based on averaging of the radio Zeeman observations in the envelope, as done by Crutcher et al. In L1544, the NIR BSP shows the envelope B -field to be significantly non-uniform and likely not suitable for averaging Zeeman properties without treating intrinsic variations. Deeper analyses of the NIR BSP and related data sets, including estimates of the B -field strength and testing how it varies with position and gas density, are the subjects of later papers in this series.

  20. Particle-in-cell simulations of collisionless magnetic reconnection with a non-uniform guide field

    International Nuclear Information System (INIS)

    Wilson, F.; Neukirch, T.; Harrison, M. G.; Hesse, M.; Stark, C. R.

    2016-01-01

    Results are presented of a first study of collisionless magnetic reconnection starting from a recently found exact nonlinear force-free Vlasov–Maxwell equilibrium. The initial state has a Harris sheet magnetic field profile in one direction and a non-uniform guide field in a second direction, resulting in a spatially constant magnetic field strength as well as a constant initial plasma density and plasma pressure. It is found that the reconnection process initially resembles guide field reconnection, but that a gradual transition to anti-parallel reconnection happens as the system evolves. The time evolution of a number of plasma parameters is investigated, and the results are compared with simulations starting from a Harris sheet equilibrium and a Harris sheet plus constant guide field equilibrium.

  1. Internal electric-field-lines distribution in CdZnTe detectors measured using X-ray mapping

    International Nuclear Information System (INIS)

    Bolotnikov, A.E.; Camarda, G.S.; Cui, Y.; Hossain, A.; Yang, G.; Yao, H.W.; James, R.B.

    2009-01-01

    The ideal operation of CdZnTe devices entails having a uniformly distributed internal electric field. Such uniformity especially is critical for thick long-drift-length detectors, such as large-volume CPG and 3-D multi-pixel devices. Using a high-spatial resolution X-ray mapping technique, we investigated the distribution of the electric field in real devices. Our measurements demonstrate that in thin detectors, 1 cm, with a large aspect ratio (thickness-to-width ratio), we observed two effects: the electric field lines bending away from or towards the side surfaces, which we called, respectively, the focusing field-line distribution and the defocusing field-line distribution. In addition to these large-scale variations, the field-line distributions were locally perturbed by the presence of extended defects and residual strains existing inside the crystals. We present our data clearly demonstrating the non-uniformity of the internal electric field

  2. Non-uniformity calibration for MWIR polarization imagery obtained with integrated microgrid polarimeters

    Science.gov (United States)

    Liu, Hai-Zheng; Shi, Ze-Lin; Feng, Bin; Hui, Bin; Zhao, Yao-Hong

    2016-03-01

    Integrating microgrid polarimeters on focal plane array (FPA) of an infrared detector causes non-uniformity of polarization response. In order to reduce the effect of polarization non-uniformity, this paper constructs an experimental setup for capturing raw flat-field images and proposes a procedure for acquiring non-uniform calibration (NUC) matrix and calibrating raw polarization images. The proposed procedure takes the incident radiation as a polarization vector and offers a calibration matrix for each pixel. Both our matrix calibration and two-point calibration are applied to our mid-wavelength infrared (MWIR) polarization imaging system with integrated microgrid polarimeters. Compared with two point calibration, our matrix calibration reduces non-uniformity by 30 40% under condition of flat-field data test with polarization. The ourdoor scene observation experiment indicates that our calibration can effectively reduce polarization non-uniformity and improve the image quality of our MWIR polarization imaging system.

  3. Weighted backprojection implemented with a non-uniform attenuation map for improved SPECT quantitation

    International Nuclear Information System (INIS)

    Manglos, S.H.; Jaszczak, R.J.; Floyd, C.E.

    1988-01-01

    A method is developed to improve quantitation in SPECT imaging by using an attenuation compensation method which includes the correct non-uniform attenuation spatial distribution (''map''). The method is based on the technique of weighted back projection, previously developed for uniform attenuation. The method is tested by imaging a non-uniform phantom, reconstructing with the known attenuation map, and quantitatively comparing the resultant image with the known activity distribution. Reconstructed image profiles are dramatically improved in comparison to reconstructions without compensation or with an assumed uniform attenuation map. Contrast measurements further quantify the improvement. Line spread function distortions seen previously in non-uniform geometries are essentially eliminated by the method. Therefore, the method appears to be appropriate for these geometries, if the non-uniform map can be determined. Some additional image distortions introduced by the compensation method are noted and will require further study

  4. Liquid-metal flow in a rectangular duct with a non-uniform magnetic field

    International Nuclear Information System (INIS)

    Walker, J.S.

    1986-04-01

    This paper treats liquid-metal flow in rectangular ducts with thin conducting walls. A transverse magnetic field changes from a uniform strength upstream to a weaker uniform strength downstream. The Hartmann number and the interaction parameter are assumed to be large, while the magnetic Reynolds number is assumed to be small. If the magnetic field changes gradually over a long duct length, the velocity and pressure are nearly uniform in each cross section and the flow differs slightly from locally fully developed flow. If the magnetic field changes more abruptly over a shorter duct length, the velocity and pressure are much larger near the walls parallel to the magnetic field than in the central part of duct. Solutions for the pressure drops due to the magnetic field change are presented

  5. Inverse analysis of non-uniform temperature distributions using multispectral pyrometry

    Science.gov (United States)

    Fu, Tairan; Duan, Minghao; Tian, Jibin; Shi, Congling

    2016-05-01

    Optical diagnostics can be used to obtain sub-pixel temperature information in remote sensing. A multispectral pyrometry method was developed using multiple spectral radiation intensities to deduce the temperature area distribution in the measurement region. The method transforms a spot multispectral pyrometer with a fixed field of view into a pyrometer with enhanced spatial resolution that can give sub-pixel temperature information from a "one pixel" measurement region. A temperature area fraction function was defined to represent the spatial temperature distribution in the measurement region. The method is illustrated by simulations of a multispectral pyrometer with a spectral range of 8.0-13.0 μm measuring a non-isothermal region with a temperature range of 500-800 K in the spot pyrometer field of view. The inverse algorithm for the sub-pixel temperature distribution (temperature area fractions) in the "one pixel" verifies this multispectral pyrometry method. The results show that an improved Levenberg-Marquardt algorithm is effective for this ill-posed inverse problem with relative errors in the temperature area fractions of (-3%, 3%) for most of the temperatures. The analysis provides a valuable reference for the use of spot multispectral pyrometers for sub-pixel temperature distributions in remote sensing measurements.

  6. The prediction of burnout in non-uniformly heated rod clusters from burnout data for uniformly heated round tubes

    International Nuclear Information System (INIS)

    Barnett, P.G.

    1964-11-01

    The practice of using burnout data for uniformly heated round tubes to predict burnout in non-uniformly heated reactor channels having complex cross sections is examined. At least two hypotheses are involved: (i) a relationship exists between uniform and non-uniform heat flux distributions and (ii) a relationship exists between simple and complex channel cross sections. Use of two such hypotheses each accurate to ± 15% and a correlation of uniformly heated round tube data having an R.M.S. error of 5%, could yield errors of ± 40% in any predicted value; this figure of ± 40% is regarded as a realistic upper limit for design purposes. It is shown that no method can exist for relating different channel cross sections to within ± 15% and existing methods for relating different heat flux distributions incur some errors exceeding 20%. Furthermore, any suggested method for relating different heat flux distributions can be adequately checked only when a sufficiently large number of results are available and then the preferable alternative of correlating the data is possible. It is concluded that no reliable method can exist for predicting burnout in rod bundles from uniformly heated round tube data with sufficient accuracy for design purposes. (author)

  7. The effects of non-uniform flow velocity on vibrations of single-walled carbon nanotube conveying fluid

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi-Goughari, Moslem [Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Hosseini, Mohammad [Sirjan University of Technology, Sirjan (Iran, Islamic Republic of)

    2015-02-15

    The vibrational behavior of a viscous nanoflow-conveying single-walled carbon nanotube (SWCNT) was investigated. The nonuniformity of the flow velocity distribution caused by the viscosity of fluid and the small-size effects on the flow field was considered. Euler-Bernoulli beam model was used to investigate flow-induced vibration of the nanotube, while the non-uniformity of the flow velocity and the small-size effects of the flow field were formulated through Knudsen number (Kn), as a discriminant parameter. For laminar flow in a circular nanotube, the momentum correction factor was developed as a function of Kn. For Kn = 0 (continuum flow), the momentum correction factor was found to be 1.33, which decreases by the increase in Kn may even reach near 1 for the transition flow regime. We observed that for passage of viscous flow through a nanotube with the non-uniform flow velocity, the critical continuum flow velocity for divergence decreased considerably as opposed to those for the uniform flow velocity, while by increasing Kn, the difference between the uniform and non-uniform flow models may be reduced. In the solution part, the differential transformation method (DTM) was used to solve the governing differential equations of motion.

  8. The effects of non-uniform flow velocity on vibrations of single-walled carbon nanotube conveying fluid

    International Nuclear Information System (INIS)

    Sadeghi-Goughari, Moslem; Hosseini, Mohammad

    2015-01-01

    The vibrational behavior of a viscous nanoflow-conveying single-walled carbon nanotube (SWCNT) was investigated. The nonuniformity of the flow velocity distribution caused by the viscosity of fluid and the small-size effects on the flow field was considered. Euler-Bernoulli beam model was used to investigate flow-induced vibration of the nanotube, while the non-uniformity of the flow velocity and the small-size effects of the flow field were formulated through Knudsen number (Kn), as a discriminant parameter. For laminar flow in a circular nanotube, the momentum correction factor was developed as a function of Kn. For Kn = 0 (continuum flow), the momentum correction factor was found to be 1.33, which decreases by the increase in Kn may even reach near 1 for the transition flow regime. We observed that for passage of viscous flow through a nanotube with the non-uniform flow velocity, the critical continuum flow velocity for divergence decreased considerably as opposed to those for the uniform flow velocity, while by increasing Kn, the difference between the uniform and non-uniform flow models may be reduced. In the solution part, the differential transformation method (DTM) was used to solve the governing differential equations of motion.

  9. Estimation of subcriticality and fuel concentration by using 'pattern matching' of neutron flux distribution under non uniformed system

    International Nuclear Information System (INIS)

    Ishitani, Kazuki; Yamane, Yoshihiro

    1999-01-01

    In nuclear fuel reprocessing plants, monitoring the spatial profile of neutron flux to infer subcriticality and distribution of fuel concentration using detectors such as PSPC, is very beneficial in sight of criticality safety. In this paper a method of subcriticality and fuel concentration estimation which is supposed to use under non-uniformed system is proposed. Its basic concept is the pattern matching between measured neutron flux distribution and beforehand calculated one. In any kind of subcriticality estimation, we can regard that measured neutron counts put any kind of black box, and then this black box outputs subcriticality. We proposed the use of artificial neural network or 'pattern matching' as black box which have no theoretical clear base. These method are wholly based on the calculated value as recently advancement of computer code accuracy for criticality safety. The most difference between indirect bias estimation method and our method is that our new approach target are the unknown non-uniform system. (J.P.N.)

  10. Leader propagation in uniform background fields in SF6

    International Nuclear Information System (INIS)

    Seeger, M; Niemeyer, L; Bujotzek, M

    2009-01-01

    The breakdown mechanism of compressed SF 6 in gas insulation is known to be controlled by stepped leader propagation. This process is still not well understood in uniform and weakly non-uniform background fields with small electrode protrusions, such as particles or surface roughness. In a previous publication an investigation of partial discharges and breakdown in uniform background fields that focused on streamer and leader inception mechanisms was presented (Seeger et al 2008 J. Phys. D: Appl. Phys. 41 185204). In this paper we present for the first time a physical leader propagation model that consistently describes the observed phenomena in uniform background fields in SF 6 . The model explains two different types of leader breakdown; these can be associated with the precursor and the stem mechanisms. It also yields the parameters of stepped leader propagation, which include step lengths, associated step charges, step times and fields and temperatures in the leader channel. Further, it explains the features of arrested leaders in uniform background fields. The model predicts the range of parameters under which arrested and breakdown leaders occur in good agreement with the experimental data.

  11. Assessment indices for uniform and non-uniform thermal environments

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Different assessment indices for thermal environments were compared and selected for proper assessment of indoor thermal environments.30 subjects reported their overall thermal sensation,thermal comfort,and thermal acceptability in uniform and non-uniform conditions.The results show that these three assessment indices provide equivalent evaluations in uniform environments.However,overall thermal sensation differs from the other two indices and cannot be used as a proper index for the evaluation of non-uniform environments.The relationship between the percentage and the mean vote for each index is established.

  12. PARTIAL ERUPTION OF A FILAMENT WITH TWISTING NON-UNIFORM FIELDS

    International Nuclear Information System (INIS)

    Bi, Yi; Jiang, Yunchun; Yang, Jiayan; Xiang, Yongyuan; Cai, Yunfang; Liu, Weiwei

    2015-01-01

    The eruption of a filament in a kinklike fashion is often regarded as a signature of kink instability. However, the kink instability threshold for the filament’s magnetic structure is not widely understood. Using Hα observations from the New Vacuum Solar Telescope, we present a partial eruptive filament. During the eruption, the filament thread appeared to split from its middle and to break out in a kinklike fashion. In this period, the remaining filament material stayed below and erupted without the kinking motion later on. The coronal magnetic field lines associated with the filament are obtained from nonlinear force-free field extrapolations using the twelve-minute-cadence vector magnetograms of the Helioseismic and Magnetic Imager (HMI) on board the Solar Dynamic Observatory. We studied the extrapolated field lines passing through the magnetic dips which are in good agreement with the observed filament. The field lines are non-uniformly twisted and appear to be composed of two twisted flux ropes winding around each other. One of them has a higher twist than the other, and the flux rope with the higher twist has its dips aligned with the kinking eruptive thread at the beginning of its eruption. Before the eruption, moreover, the flux rope with the higher twist was found to expand with an approximately constant field twist. In addition, the helicity flux maps deduced from the HMI magnetograms show that some helicity is injected into the overlying magnetic arcade, but no significant helicity is injected into the flux ropes. Accordingly, we suggest that the highly twisted flux rope became kink unstable when the instability threshold declined with the expansion of the flux rope

  13. Experimental study on the CHF in uniformly and non-uniformly heated vertical annuli

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Se Young; Moon, Sang Ki; Chung, Heung June; Park, Jong Kuk; Kim, Bok Deuk; Youn, Young Jung; Chung, Moon Ki

    2001-09-01

    Up to now, KAERI has performed critical heat flux experiments in water under zero-flow and low-flow conditions using a RCS CHF loop facility with uniformly and non-uniformly heated vertical annulus. Since the existing CHF experiments were mainly performed under low-pressure conditions, we performed the CHF experiment to investigate the pressure effect on the CHF under zero-flow and low-flow conditions for a wide range of system pressures. Also, two vertical annuli with the same geometry have been used to investigate the axial heat flux distributions on the CHF. This report summarizes the experimental results and provides the CHF data that can be used for the development for CHF correlation and a thermal hydraulic analysis code. The CHF data have been collected for system pressures ranging from 0.57 to 15.15 MPa, mass flux 0 and from 200 to 650 kg/m2s, inlet subcooling from 75 to 360 kJ/kg and exit quality from 0.07 to 0.57. At low-flow conditions, the total number of data are 242 and 290 with uniformly heated- and non-uniformly heated test sections, respectively. 41 and 94 CHF data are generated with uniformly heated- and non-uniformly heated test sections, respectively, in zero-flow CHF experiments that are performed by blocking test section bottoms. The CHF experiment result shows that the effects of system pressure, mass flux and inlet subcooling are consistent with conventional understandings and similar to those for round tubes. The behavior of the CHF is relatively complex at low pressures. Also, the effects of axial heat flux profile are large at low-pressure conditions.

  14. Experimental study on the CHF in uniformly and non-uniformly heated vertical annuli

    International Nuclear Information System (INIS)

    Chun, Se Young; Moon, Sang Ki; Chung, Heung June; Park, Jong Kuk; Kim, Bok Deuk; Youn, Young Jung; Chung, Moon Ki

    2001-09-01

    Up to now, KAERI has performed critical heat flux experiments in water under zero-flow and low-flow conditions using a RCS CHF loop facility with uniformly and non-uniformly heated vertical annulus. Since the existing CHF experiments were mainly performed under low-pressure conditions, we performed the CHF experiment to investigate the pressure effect on the CHF under zero-flow and low-flow conditions for a wide range of system pressures. Also, two vertical annuli with the same geometry have been used to investigate the axial heat flux distributions on the CHF. This report summarizes the experimental results and provides the CHF data that can be used for the development for CHF correlation and a thermal hydraulic analysis code. The CHF data have been collected for system pressures ranging from 0.57 to 15.15 MPa, mass flux 0 and from 200 to 650 kg/m2s, inlet subcooling from 75 to 360 kJ/kg and exit quality from 0.07 to 0.57. At low-flow conditions, the total number of data are 242 and 290 with uniformly heated- and non-uniformly heated test sections, respectively. 41 and 94 CHF data are generated with uniformly heated- and non-uniformly heated test sections, respectively, in zero-flow CHF experiments that are performed by blocking test section bottoms. The CHF experiment result shows that the effects of system pressure, mass flux and inlet subcooling are consistent with conventional understandings and similar to those for round tubes. The behavior of the CHF is relatively complex at low pressures. Also, the effects of axial heat flux profile are large at low-pressure conditions

  15. Analysis and Optimization for Uniformity of Magnetic Field Driving the Giant Magnetostriction

    International Nuclear Information System (INIS)

    Wang, L; Ye, H; Liu, Y T; Yao, S M

    2006-01-01

    Giant magnetostriction actuator based on material Tb0.27Dy0.73Fe2 and electromagnetic transform has characteristics of high frequency response, large output power and etc, but it has a high demand for the uniformity of magnetic field driver and magnetic intensity. Object to the problem, a multi-scale external concavity structure is proposed, by means of inducting the hollow column coil structure, building the model of coil magnetic distribution and analyzing by finite element analysis method. The analysis results show that uniformity of the model magnetic field is dependent upon magnetic intensity and scales, and the boundary condition of material. As the scale increases, magnetic uniformity is enhanced, but the magnetic intensity is decreased. Taking consideration both of magnetic field distribution and magnetic intensity, threescale structure is determined as optimum structure

  16. Non-Uniformity Correction Using Nonlinear Characteristic Performance Curves for Calibration

    Science.gov (United States)

    Lovejoy, McKenna Roberts

    Infrared imaging is an expansive field with many applications. Advances in infrared technology have lead to a greater demand from both commercial and military sectors. However, a known problem with infrared imaging is its non-uniformity. This non-uniformity stems from the fact that each pixel in an infrared focal plane array has its own photoresponse. Many factors such as exposure time, temperature, and amplifier choice affect how the pixels respond to incoming illumination and thus impact image uniformity. To improve performance non-uniformity correction (NUC) techniques are applied. Standard calibration based techniques commonly use a linear model to approximate the nonlinear response. This often leaves unacceptable levels of residual non-uniformity. Calibration techniques often have to be repeated during use to continually correct the image. In this dissertation alternates to linear NUC algorithms are investigated. The goal of this dissertation is to determine and compare nonlinear non-uniformity correction algorithms. Ideally the results will provide better NUC performance resulting in less residual non-uniformity as well as reduce the need for recalibration. This dissertation will consider new approaches to nonlinear NUC such as higher order polynomials and exponentials. More specifically, a new gain equalization algorithm has been developed. The various nonlinear non-uniformity correction algorithms will be compared with common linear non-uniformity correction algorithms. Performance will be compared based on RMS errors, residual non-uniformity, and the impact quantization has on correction. Performance will be improved by identifying and replacing bad pixels prior to correction. Two bad pixel identification and replacement techniques will be investigated and compared. Performance will be presented in the form of simulation results as well as before and after images taken with short wave infrared cameras. The initial results show, using a third order

  17. Effect of sprinkler structure on water distribution uniformity

    International Nuclear Information System (INIS)

    Xu, M; Li, H; Chen, C; Tu, Q; Liu, J P

    2012-01-01

    Structures of sprinklers play important roles in the uniformity of water distribution. The advances and achievements to improve the distribution uniformity through the innovation in the sprinkler structures at home and abroad were presented in details. Analyses showed that three types of structure can ameliorate the water distribution efficiently. First, novel nozzle structures were applied, including the application of non-circle nozzle and special spread nozzles. Second, new structures of flow channel were used. Third, assistant device was added so as to improve the uneven water distribution, such as an assistant stream interrupter, pressure or flow rate regulator and so on. Compared to domestic sprinklers, sprinklers produced abroad have novel and special structures with better hydraulic performance. Basic theoretical researches should be strengthened and new materials, new manufacturing processes and new technique should be applied. Then new kinds of sprinkler will be produced and the hydraulic performance of sprinklers will be promoted to a higher level.

  18. Numerical investigation of the heat transfer of a ferrofluid inside a tube in the presence of a non-uniform magnetic field

    Science.gov (United States)

    Hariri, Saman; Mokhtari, Mojtaba; Gerdroodbary, M. Barzegar; Fallah, Keivan

    2017-02-01

    In this article, a three-dimensional numerical investigation is performed to study the effect of a magnetic field on a ferrofluid inside a tube. This study comprehensively analyzes the influence of a non-uniform magnetic field in the heat transfer of a tube while a ferrofluid (water with 0.86 vol% nanoparticles (Fe3O4) is let flow. The SIMPLEC algorithm is used for obtaining the flow and heat transfer inside the tube. The influence of various parameters, such as concentration of nanoparticles, intensity of the magnetic field, wire distance and Reynolds number, on the heat transfer is investigated. According to the obtained results, the presence of a non-uniform magnetic field significantly increases the Nusselt number (more than 300%) inside the tube. Also, the magnetic field induced by the parallel wire affects the average velocity of the ferrofluid and forms two strong eddies in the tube. Our findings show that the diffusion also raises as the concentration of the nanoparticle is increased.

  19. Prediction of the Velocity Contours in Triangular Channel with Non-uniform Roughness Distributions by Adaptive Neuro-Fuzzy Inference System

    Directory of Open Access Journals (Sweden)

    Sara Bardestani

    2017-09-01

    Full Text Available Triangular channels have different applications in many water and wastewater engineering problems. For this purpose investigating hydraulic characteristics of flow in these sections has great importance. Researchers have presented different prediction methods for the velocity contours in prismatic sections. Most proposed methods are not able to consider the effect of walls roughness, the roughness distribution and secondary flows. However, due to complexity and nonlinearity of velocity contours in open channel flow, there is no simple relationship that can be fully able to exactly draw the velocity contours. In this paper an efficient approach for modeling velocity contours in triangular open channels with non-uniform roughness distributions by Adaptive Neuro-Fuzzy Inference System (ANFIS has been suggested. For training and testing model, the experimental data including 1703 data in triangular channels with geometric symmetry and non-uniform roughness distributions have been used. Comparing experimental results with predicted values by model indicates that ANFIS model is capable to be used in simulation of local velocity and determining velocity contours and the independent evaluation showed that the calculated values of discharge and depth-averaged velocity from model information are precisely in conformity with experimental values.

  20. PARALLEL AND ADAPTIVE UNIFORM-DISTRIBUTED REGISTRATION METHOD FOR CHANG’E-1 LUNAR REMOTE SENSED IMAGERY

    Directory of Open Access Journals (Sweden)

    X. Ning

    2012-08-01

    To resolve the above-mentioned registration difficulties, a parallel and adaptive uniform-distributed registration method for CE-1 lunar remote sensed imagery is proposed in this paper. Based on 6 pairs of randomly selected images, both the standard SIFT algorithm and the parallel and adaptive uniform-distributed registration method were executed, the versatility and effectiveness were assessed. The experimental results indicate that: by applying the parallel and adaptive uniform-distributed registration method, the efficiency of CE-1 lunar remote sensed imagery registration were increased dramatically. Therefore, the proposed method in the paper could acquire uniform-distributed registration results more effectively, the registration difficulties including difficult to obtain results, time-consuming, non-uniform distribution could be successfully solved.

  1. Nu shifts in betatron oscillations from uniform perturbations in the presence of non-linear magnetic guide fields

    International Nuclear Information System (INIS)

    Crebbin, K.C.

    1985-05-01

    Uniform magnetic field perturbations cause a closed orbit distortion in a circular accelerator. If the magnetic guide field is non-linear these perturbations can also cause a Nu shift in the betatron oscillations. Such a shift in radial Nu values has been observed in the Bevalac while studying the low energy resonant extraction system. In the Bevalac, the radial perturbation comes from the quadrants being magnetically about 0.8% longer than 90 0 . The normal effect of this type of perturbation is a radial closed orbit shift and orbit distortion. The Nu shift, associated with this type of perturbation in the presence of a non-linear guide field, is discussed in this paper. A method of handling the non-linear n values is discussed as well as the mechanism for the associated Nu shift. Computer calculations are compared to measurements. 2 refs., 4 figs

  2. Monte Carlo simulation of scatter in non-uniform symmetrical attenuating media for point and distributed sources

    International Nuclear Information System (INIS)

    Henry, L.J.; Rosenthal, M.S.

    1992-01-01

    We report results of scatter simulations for both point and distributed sources of 99m Tc in symmetrical non-uniform attenuating media. The simulations utilized Monte Carlo techniques and were tested against experimental phantoms. Both point and ring sources were used inside a 10.5 cm radius acrylic phantom. Attenuating media consisted of combinations of water, ground beef (to simulate muscle mass), air and bone meal (to simulate bone mass). We estimated/measured energy spectra, detector efficiencies and peak height ratios for all cases. In all cases, the simulated spectra agree with the experimentally measured spectra within 2 SD. Detector efficiencies and peak height ratios also are in agreement. The Monte Carlo code is able to properly model the non-uniform attenuating media used in this project. With verification of the simulations, it is possible to perform initial evaluation studies of scatter correction algorithms by evaluating the mechanisms of action of the correction algorithm on the simulated spectra where the magnitude and sources of scatter are known. (author)

  3. UOBPRM: A uniformly distributed obstacle-based PRM

    KAUST Repository

    Yeh, Hsin-Yi

    2012-10-01

    This paper presents a new sampling method for motion planning that can generate configurations more uniformly distributed on C-obstacle surfaces than prior approaches. Here, roadmap nodes are generated from the intersections between C-obstacles and a set of uniformly distributed fixed-length segments in C-space. The results show that this new sampling method yields samples that are more uniformly distributed than previous obstacle-based methods such as OBPRM, Gaussian sampling, and Bridge test sampling. UOBPRM is shown to have nodes more uniformly distributed near C-obstacle surfaces and also requires the fewest nodes and edges to solve challenging motion planning problems with varying narrow passages. © 2012 IEEE.

  4. The effects of relativistic and non-local non-linearities on modulational instabilities in non-uniform plasma

    International Nuclear Information System (INIS)

    Mohamed, B.F.; El-Shorbagy, Kh.H.

    2000-01-01

    A general detailed analysis for the nonlinear generation of localized fields due to the existence of a strong pump field inside the non-uniform plasma has been considered. We have taken into account the effects of relativistic and non-local nonlinearities on the structure of plasma resonance region. The nonlinear Schrodinger equation described the localized fields are investigated. Besides, the generalized dispersion relation is obtained to study the modulational instabilities in different cases. Keywords: Wave-plasma interaction, Nonlinear effects, Modulation instabilities

  5. Current limitation and formation of plasma double layers in a non-uniform magnetic field

    International Nuclear Information System (INIS)

    Plamondon, R.; Teichmann, J.; Torven, S.

    1986-07-01

    Formation of strong double layers has been observed experimentally in a magnetised plasma column maintained by a plasma source. The magnetic field is approximately axially homogenous except in a region at the anode where the electric current flows into a magnetic mirror. The double layer has a stationary position only in the region of non-uniform magnetic field or at the aperture separating the source and the plasma column. It is characterized by a negative differential resistance in the current-voltage characteristic of the device. The parameter space,where the double layer exists, has been studied as well as the corresponding potential profiles and fluctuation spectra. The electric current and the axial electric field are oppositely directed between the plasma source and a potential minimum which is formed in the region of inhomogeneous magnetic field. Electron reflection by the resulting potential barrier is found to be an important current limitation mechanism. (authors)

  6. Mechanical Effects of the Non-Uniform Current Distribution on HTS Coils for Accelerators Wound with REBCO Roebel Cable

    CERN Document Server

    Murtomaeki, Jaako; Kirby, Glen; Rossi, Lucio; Ruuskanen, Janne; Stenvall, Antti; Murtomaeki, Jaako

    2017-01-01

    Future high-energy accelerators will need very high magnetic fields in the range of 20 T. The EuCARD-2 WP10 Future Magnets collaboration is aiming at testing HTS-based Roebel cables in an accelerator magnet. The demonstrator should produce around 17 T, when inserted into the 100 mm aperture of Feather-M2 13 T outsert magnet. HTS Roebel cables are assembled from meander shaped REBCO coated conductor tapes. In comparison with fair level of uniformity of current distribution in cables made out of round Nb-Ti or Nb$_{3}$Sn strands, current distribution within the coils wound from Roebel cables is highly non-homogeneous. It results in nonuniform electromagnetic force distribution over the cable that could damage the very thin REBCO superconducting layer. This paper focuses on the numerical models to describe the effect of the non-homogenous current distribution on stress distribution in the demonstrator magnet designed for the EuCARD-2 project. Preliminary results indicate that the impregnation bonding betweenthe...

  7. Heterogeneous analysis of non-uniform neutron field formation

    International Nuclear Information System (INIS)

    Zagrebaev, A.M.; Fedosov, A.M.

    1979-01-01

    Investigated are the specific features of spatial-energy neutron distribution formation in the transient zone between regions, operating at different levels of energy release with accounting for the real structure of fuel element lattice and control elements in the channel reactors of high power. Presented are the calculation results, obtained by heterogeneous method in the two-group monopole approximation by means of the HETLAT code. The analysis, based on the homogeneous model shows, that the efficiency of the transient zone in forming neutron flux qradient can be increased by introducing an additional interlayer of moderator between the layers with extreme multiplying properties. It is stressed, that the most favourable from the point of view of energy release uniformity in zones and width of the transient zone is the variant in which neutron flux gradient is carried out by moving the control elements on the boundaries of regions while the internal rows of control elements create the conditions for flattening the energy release in the zones. The result obtained corresponds to the recommendation on optimal control, coming from the Pontryagin maximum principle. The analysis of neutron field formation using heterogeneous models mainly proves the conclusions following from homogeneous calculations using the maximum principle. At the same time quantitative results for the zones of small dimensions (less than 10 migration lengths) with a vividly expressed heterogeneous structure essentially differ from the forecast, obtained on the basis of the simplified homogeneous one-group model. The heterogeneous analysis shows possibilities for further optimization of the transient zone structure with account of the control element location

  8. Assessment of 12 CHF prediction methods, for an axially non-uniform heat flux distribution, with the RELAP5 computer code

    Energy Technology Data Exchange (ETDEWEB)

    Ferrouk, M. [Laboratoire du Genie Physique des Hydrocarbures, University of Boumerdes, Boumerdes 35000 (Algeria)], E-mail: m_ferrouk@yahoo.fr; Aissani, S. [Laboratoire du Genie Physique des Hydrocarbures, University of Boumerdes, Boumerdes 35000 (Algeria); D' Auria, F.; DelNevo, A.; Salah, A. Bousbia [Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Universita di Pisa (Italy)

    2008-10-15

    The present article covers the evaluation of the performance of twelve critical heat flux methods/correlations published in the open literature. The study concerns the simulation of an axially non-uniform heat flux distribution with the RELAP5 computer code in a single boiling water reactor channel benchmark problem. The nodalization scheme employed for the considered particular geometry, as modelled in RELAP5 code, is described. For this purpose a review of critical heat flux models/correlations applicable to non-uniform axial heat profile is provided. Simulation results using the RELAP5 code and those obtained from our computer program, based on three type predictions methods such as local conditions, F-factor and boiling length average approaches were compared.

  9. Uniform and non-uniform modes of nanosecond-pulsed dielectric barrier discharge in atmospheric air: fast imaging and spectroscopic measurements of electric field.

    Science.gov (United States)

    Liu, Chong; Dobrynin, Danil; Fridman, Alexander

    2014-06-25

    In this study, we report experimental results on fast ICCD imaging of development of nanosecond-pulsed dielectric barrier discharge (DBD) in atmospheric air and spectroscopic measurements of electric field in the discharge. Uniformity of the discharge images obtained with nanosecond exposure times were analyzed using chi-square test. The results indicate that DBD uniformity strongly depends on applied (global) electric field in the discharge gap, and is a threshold phenomenon. We show that in the case of strong overvoltage on the discharge gap (provided by fast rise times), there is transition from filamentary to uniform DBD mode which correlates to the corresponding decrease of maximum local electric field in the discharge.

  10. Determining irrigation distribution uniformity and efficiency for nurseries

    Science.gov (United States)

    R. Thomas Fernandez

    2010-01-01

    A simple method for testing the distribution uniformity of overhead irrigation systems is described. The procedure is described step-by-step along with an example. Other uses of distribution uniformity testing are presented, as well as common situations that affect distribution uniformity and how to alleviate them.

  11. [Measures of occupational exposure to time-varying low frequency magnetic fields of non-uniform spatial distribution in the light of international guidelines and electrodynamic exposure effects in the human body].

    Science.gov (United States)

    Karpowicz, Jolanta; Zradziński, Patryk; Gryz, Krzysztof

    2012-01-01

    The aim of study was to analyze by computer simulations the electrodynamic effects of magnetic field (MF) on workers, to harmonize the principles of occupational hazards assessment with international guidelines. Simulations involved 50 Hz MF of various spatial distributions, representing workers' exposure in enterprises. Homogeneous models of sigma = 0.2 S/m conductivity and dimensions of body parts - palm, head and trunk - were located at 50 cm ("hand-distance") or 5 cm (adjacent) from the source (circle conductor of 20 cm or 200 cm in diameter). Parameters of magnetic flux density (B(i)) affecting the models were the exposure measures, and the induced electric field strength (E(in)) was the measure of MF exposure effects. The ratio E(in)/B(i) in the analyzed cases ranged from 2.59 to 479 (V/m)/T. The strongest correlation (p assessing the effects of non-uniform fields exposure, resulting from a strong dependence of the E(in)/B(i) ratio on the conditions of exposure and its applied measures, requires special caution when defining the permissible MF levels and the principles of exposure assessment at workplace.

  12. Molecular response to a time-independent non-uniform magnetic-field

    International Nuclear Information System (INIS)

    Faglioni, F.; Ligabue, A.; Pelloni, S.; Soncini, A.; Lazzeretti, P.

    2004-01-01

    The response of a molecule to a static inhomogeneous magnetic-field is rationalized via multipole magnetic susceptibilities and induced magnetic multipole and anapole moments. The energy of the molecule interacting with the external field is expressed as a Taylor series in the powers of the field and its gradient at the origin of the coordinate system. It involves magnetic multipole tensors of increasing rank, which can be evaluated via quantum mechanical approaches. An electronic energy shift is caused by the feed-back interaction between the induced magnetic dipole moment and the external magnetic field, and between the induced magnetic quadrupole moment and the gradient of the magnetic field. It is shown that, for a static magnetic field with uniform gradient, the magnetic quadrupole moment is origin-dependent, but the total interaction energy and the induced magnetic dipole are invariant to a translation of the coordinate system. The formal advantages of a Geertsen approach to third- and fourth-rank mixed-multipole susceptibilities are discussed

  13. Uniform and non-uniform modes of nanosecond-pulsed dielectric barrier discharge in atmospheric air: fast imaging and spectroscopic measurements of electric field

    Science.gov (United States)

    Liu, Chong; Dobrynin, Danil; Fridman, Alexander

    2014-01-01

    In this study, we report experimental results on fast ICCD imaging of development of nanosecond-pulsed dielectric barrier discharge (DBD) in atmospheric air and spectroscopic measurements of electric field in the discharge. Uniformity of the discharge images obtained with nanosecond exposure times were analyzed using chi-square test. The results indicate that DBD uniformity strongly depends on applied (global) electric field in the discharge gap, and is a threshold phenomenon. We show that in the case of strong overvoltage on the discharge gap (provided by fast rise times), there is transition from filamentary to uniform DBD mode which correlates to the corresponding decrease of maximum local electric field in the discharge. PMID:25071294

  14. A method for producing uniform dose distributions in the junction regions of large hinge angle electrol fields

    International Nuclear Information System (INIS)

    Zavgorodni, S.F.; Beckham, W.A.; Roos, D.E.

    1996-01-01

    The planning problems presented by abutting electron fields are well recognised. Junctioning electron fields with large hinge angle compounds the problems because of the creation of closely situated 'hot' and 'cold' spots. The technique involving a compensated superficial x-ray (SXR) field to treat the junction region between electron fields was developed and used in a particular clinical case (treatment of a squamous cell carcinoma of the forehead/scalp). The SXR beam parameters were chosen and the compensator was designed to make the SXR field complementary to the electron fields. Application of a compensated SXR field eliminated 'cold' spots in the junction region and minimised 'hot' spots to (110%). In the clinical case discusses the 'hot' spots due to the SXR field would not appear because of increased attenuation of the soft x-rays in bone. The technique proposed produces uniform dose distribution up to 3 cm deep and can be considered as an additional tool for dealing with electron fields junctioning problems. (author)

  15. Instruction sequence based non-uniform complexity classes

    NARCIS (Netherlands)

    Bergstra, J.A.; Middelburg, C.A.

    2013-01-01

    We present an approach to non-uniform complexity in which single-pass instruction sequences play a key part, and answer various questions that arise from this approach. We introduce several kinds of non-uniform complexity classes. One kind includes a counterpart of the well-known non-uniform

  16. Temporal high-pass non-uniformity correction algorithm based on grayscale mapping and hardware implementation

    Science.gov (United States)

    Jin, Minglei; Jin, Weiqi; Li, Yiyang; Li, Shuo

    2015-08-01

    In this paper, we propose a novel scene-based non-uniformity correction algorithm for infrared image processing-temporal high-pass non-uniformity correction algorithm based on grayscale mapping (THP and GM). The main sources of non-uniformity are: (1) detector fabrication inaccuracies; (2) non-linearity and variations in the read-out electronics and (3) optical path effects. The non-uniformity will be reduced by non-uniformity correction (NUC) algorithms. The NUC algorithms are often divided into calibration-based non-uniformity correction (CBNUC) algorithms and scene-based non-uniformity correction (SBNUC) algorithms. As non-uniformity drifts temporally, CBNUC algorithms must be repeated by inserting a uniform radiation source which SBNUC algorithms do not need into the view, so the SBNUC algorithm becomes an essential part of infrared imaging system. The SBNUC algorithms' poor robustness often leads two defects: artifacts and over-correction, meanwhile due to complicated calculation process and large storage consumption, hardware implementation of the SBNUC algorithms is difficult, especially in Field Programmable Gate Array (FPGA) platform. The THP and GM algorithm proposed in this paper can eliminate the non-uniformity without causing defects. The hardware implementation of the algorithm only based on FPGA has two advantages: (1) low resources consumption, and (2) small hardware delay: less than 20 lines, it can be transplanted to a variety of infrared detectors equipped with FPGA image processing module, it can reduce the stripe non-uniformity and the ripple non-uniformity.

  17. Modelling the actual behaviour of the MOX fuel by a micromechanical analysis in non-uniform transformation fields

    International Nuclear Information System (INIS)

    Largenton, R.

    2012-01-01

    This research thesis aimed at developing a model based on scale change to assess more precisely the distribution of local thermo-mechanical fields within a heterogeneous medium as MOX fuel. The analysis method is a non-uniform transformation field analysis (NTFA) which is adapted to the problem of scale change in presence of a coupling between dissipative and elastic effects. More precisely, the author addressed the development of a NTFA model based on specific three-phase and three-dimensional microstructures which are typical of the MOX fuel in an in-service operation. The first part proposes an overview of knowledge and use of MOX. It recalls the context and the industrial problematic associated with this fuel: operating principles for a 900 MWe PWR, fuel fabrication processes, fuel morphologies and structural and microstructural consequences. It addresses local mechanisms within each phase during irradiation, and presents the approach methodology regarding scale change. The second part reports the representation and analysis in complete fields of multiphase particle-based composites (MOX type) in order to determine the representative elementary volume and the local behaviour of each phase. The third part reports the extension of the NTFA approach to 3D aspects, free deformations, ageing and optimization. The last part compares the NTFA approach with the incremental two-phase and three-phase Mori-Tanaka models

  18. Uniform and non-uniform modes of nanosecond-pulsed dielectric barrier discharge in atmospheric air: fast imaging and spectroscopic measurements of electric fields

    International Nuclear Information System (INIS)

    Liu, Chong; Dobrynin, Danil; Fridman, Alexander

    2014-01-01

    In this study, we report experimental results on fast intensified charge-coupled device (ICCD) imaging of the development of nanosecond-pulsed dielectric barrier discharge (DBD) in atmospheric air and spectroscopic measurements of the electric field in the discharge. The uniformity of the discharge images obtained with nanosecond exposure times was analysed using chi-square test. The results indicate that DBD uniformity strongly depends on the applied (global) electric field in the discharge gap, which is a threshold phenomenon. We show that in the case of strong overvoltage on the discharge gap (provided by fast rise times), there is a transition from filamentary to uniform DBD mode that correlates to the corresponding decrease of the maximum local electric field in the discharge. (fast track communication)

  19. The impact of non-uniform channel layer growth on device characteristics in state of the Art Si/SiGe/Si p-metal oxide semiconductor field effect transistors

    International Nuclear Information System (INIS)

    Chang, A.C.K.; Ross, I.M.; Norris, D.J.; Cullis, A.G.; Tang, Y.T.; Cerrina, C.; Evans, A.G.R.

    2006-01-01

    In this study we have highlighted the effect of non-uniform channel layer growth by the direct correlation of the microstructure and electrical characteristics in state-of-the-art pseudomorphic Si/SiGe p-channel metal oxide semiconductor field effect transistor devices fabricated on Si. Two nominally identical sets of devices from adjacent locations of the same wafer were found to have radically different distributions in gate threshold voltages. Due to the close proximity and narrow gate length of the devices, focused ion beam milling was used to prepare a number of thin cross-sections from each of the two regions for subsequent analysis using transmission electron microscopy. It was found that devices from the region giving a very narrow range of gate threshold voltages exhibited a uniform microstructure in general agreement with the intended growth parameters. However, in the second region, which showed a large spread in the gate threshold voltages, profound anomalies in the microstructure were observed. These anomalies consisted of fluctuations in the quality and thickness of the SiGe strained layers. The non-uniform growth of the strained SiGe layer clearly accounted for the poorly controlled threshold voltages of these devices. The results emphasize the importance of good layer growth uniformity to ensure optimum device yield

  20. Flood field uniformity testing - effects of crystal hydration

    International Nuclear Information System (INIS)

    Dimcheva, M.; Sergieva, S.; Doldurova, M.; Jovanovska, A.

    2012-01-01

    The most basic and sensitive routine quality control (QC) of gamma camera is that of intrinsic flood-field uniformity. The routine QC test must be assessed daily and any nonuniformity must be eliminated before patient testing to eliminate artifacts and false positive or false-negative patient results. The purpose of this study was to compare uniformity analysis results for scintillation crystal hydration with symmetric and asymmetric energy window on the Siemens Symbia T2 SPECTCT camera. Integral and differential uniformity analysis was performed by placing a point source 99m Tc in front of the detector with removed collimator to measure the effect of correction matrix, a count rate and activity volume on intrinsic uniformity. A 15% energy window set symmetrically over the 99m Tc photo peak is equivalent to 140±10% keV or a window spanning 126-154 keV. The results, received from Detector 2 gave the following uniformity parameter values: Both asymmetric energy window images show clearly multiple focal spots due to crystal hydration: discrete hot spots in the asymmetric low window image and discrete cold spots in the asymmetric high window image. The above results are not seen yet on the symmetric window image. We had replaced Detector 2 in order to avoid spots become visible in flood images obtained with the clinical energy window. The uniformity of a gamma camera is maybe the most important parameter that expresses the quality of the camera's performance. Non uniform areas in the field of view can result in misdiagnosed patients and low quality of clinical services. (authors)

  1. Experimental and numerical studies of pressure drop in PbLi flows in a circular duct under non-uniform transverse magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Li, F.-C., E-mail: lifch@hit.edu.cn; Sutevski, D.; Smolentsev, S.; Abdou, M.

    2013-11-15

    Highlights: • An indirect DP measurement approach for high-temperature LM MHD flow is developed. • Experiments and numerical simulations of PbLi MHD flow are performed. • Characteristics of DP in LM MHD flow under fringing magnetic field are studied. • Pressure distributions in LM MHD flow at entry and exit of magnet are different. -- Abstract: Experiments and three-dimensional (3D) numerical simulations are performed to investigate the magnetohydrodynamic (MHD) characteristics of liquid metal (LM) flows of molten lead-lithium (PbLi) eutectic alloy in an electrically conducting circular duct subjected to a transverse non-uniform (fringing) magnetic field. An indirect measurement approach for differential pressure in high temperature LM PbLi is first developed, and then detailed data on pressure drop in this PbLi MHD flow are measured. The obtained experimental results for the pressure distribution are in good agreement with numerical simulations. Using the numerical simulation results, the 3D effects caused by fringing magnetic field on the LM flow are illustrated via distributions for the axial pressure gradients and transverse pressure differences. It has been verified that a simple approach for estimation of pressure drop in LM MHD flow in a fringing magnetic field proposed by Miyazaki et al. [22] i.e., a simple integral of pressure gradient along the fringing field zone using a quasi-fully-developed flow assumption, is also applicable to the conditions of the present experiment providing the magnetic interaction parameter is large enough. Furthermore, for two different sections of the LM flow at the entry to and at the exit from the magnet, it is found that the pressure distributions in the duct cross sections in these two regions are different.

  2. Thermal freeze-out and longitudinally non-uniform collective expansion flow in relativistic heavy ion collisions

    CERN Document Server

    Feng Sheng Qin; LianShouLiu

    2002-01-01

    The non-uniform longitudinal flow model (NUFM) proposed recently is extended to include also the transverse flow. The resulting longitudinally non-uniform collective expansion model (NUCEM) is applied to the calculation of rapidity distribution of kaons, lambdas and protons in relativistic heavy ion collisions at CERN-SPS energies. The model results are compared with the 200 A GeV/c S-S and 158 A GeV/c Pb-Pb collision data. The central dips observed in experiments are reproduced in a natural way. It is found that the depth of the central dip depends on the magnitude of the parameter e and the mass of produced particles, i.e. the non-uniformity of the longitudinal flow which is described by the parameter e determines the depth of the central dip for produced particles. Comparing with one-dimensional non-uniform longitudinal flow model, the rapidity distribution of lighter strange particle kaon also shows a dip due to the effect of transverse flow

  3. Optimal threshold of error decision related to non-uniform phase distribution QAM signals generated from MZM based on OCS

    Science.gov (United States)

    Han, Xifeng; Zhou, Wen

    2018-03-01

    Optical vector radio-frequency (RF) signal generation based on optical carrier suppression (OCS) in one Mach-Zehnder modulator (MZM) can realize frequency-doubling. In order to match the phase or amplitude of the recovered quadrature amplitude modulation (QAM) signal, phase or amplitude pre-coding is necessary in the transmitter side. The detected QAM signals usually have one non-uniform phase distribution after square-law detection at the photodiode because of the imperfect characteristics of the optical and electrical devices. We propose to use optimal threshold of error decision for non-uniform phase contribution to reduce the bit error rate (BER). By employing this scheme, the BER of 16 Gbaud (32 Gbit/s) quadrature-phase-shift-keying (QPSK) millimeter wave signal at 36 GHz is improved from 1 × 10-3 to 1 × 10-4 at - 4 . 6 dBm input power into the photodiode.

  4. Effective electrodiffusion equation for non-uniform nanochannels.

    Science.gov (United States)

    Marini Bettolo Marconi, Umberto; Melchionna, Simone; Pagonabarraga, Ignacio

    2013-06-28

    We derive a one-dimensional formulation of the Planck-Nernst-Poisson equation to describe the dynamics of a symmetric binary electrolyte in channels whose section is nanometric and varies along the axial direction. The approach is in the spirit of the Fick-Jacobs diffusion equation and leads to a system of coupled equations for the partial densities which depends on the charge sitting at the walls in a non-trivial fashion. We consider two kinds of non-uniformities, those due to the spatial variation of charge distribution and those due to the shape variation of the pore and report one- and three-dimensional solutions of the electrokinetic equations.

  5. Additive non-uniform random sampling in superimposed fiber Bragg grating strain gauge

    Science.gov (United States)

    Ma, Y. C.; Liu, H. Y.; Yan, S. B.; Yang, Y. H.; Yang, M. W.; Li, J. M.; Tang, J.

    2013-05-01

    This paper demonstrates an additive non-uniform random sampling and interrogation method for dynamic and/or static strain gauge using a reflection spectrum from two superimposed fiber Bragg gratings (FBGs). The superimposed FBGs are designed to generate non-equidistant space of a sensing pulse train in the time domain during dynamic strain gauge. By combining centroid finding with smooth filtering methods, both the interrogation speed and accuracy are improved. A 1.9 kHz dynamic strain is measured by generating an additive non-uniform randomly distributed 2 kHz optical sensing pulse train from a mean 500 Hz triangular periodically changing scanning frequency.

  6. On the Pressure of a Neutron Gas Interacting with the Non-Uniform Magnetic Field of a Neutron Star

    Science.gov (United States)

    Skobelev, V. V.

    2018-04-01

    On the basis of simple arguments, practically not going beyond the scope of an undergraduate course in general physics, we estimate the additional pressure (at zero temperature) of degenerate neutron matter due to its interaction with the non-uniform magnetic field of a neutron star. This work has methodological and possibly scientific value as an intuitive application of the content of such a course to a solution of topical problems of astrophysics.

  7. Additive non-uniform random sampling in superimposed fiber Bragg grating strain gauge

    International Nuclear Information System (INIS)

    Ma, Y C; Liu, H Y; Yan, S B; Li, J M; Tang, J; Yang, Y H; Yang, M W

    2013-01-01

    This paper demonstrates an additive non-uniform random sampling and interrogation method for dynamic and/or static strain gauge using a reflection spectrum from two superimposed fiber Bragg gratings (FBGs). The superimposed FBGs are designed to generate non-equidistant space of a sensing pulse train in the time domain during dynamic strain gauge. By combining centroid finding with smooth filtering methods, both the interrogation speed and accuracy are improved. A 1.9 kHz dynamic strain is measured by generating an additive non-uniform randomly distributed 2 kHz optical sensing pulse train from a mean 500 Hz triangular periodically changing scanning frequency. (paper)

  8. Non-uniform sampling of NMR relaxation data

    DEFF Research Database (Denmark)

    Schwarz-Linnet, Troels; Teilum, Kaare

    2016-01-01

    The use of non-uniform sampling of NMR spectra may give significant reductions in the data acquisition time. For quantitative experiments such as the measurement of spin relaxation rates, non-uniform sampling is however not widely used as inaccuracies in peak intensities may lead to errors...... in the extracted dynamic parameters. By systematic reducing the coverage of the Nyquist grid of (15)N Carr-Purcell-Meiboom-Gill (CPMG) relaxation dispersion datasets for four different proteins and performing a full data analysis of the resulting non-uniform sampled datasets, we have compared the performance...... of the multi-dimensional decomposition and iterative re-weighted least-squares algorithms in reconstructing spectra with accurate peak intensities. As long as a single fully sampled spectrum is included in a series of otherwise non-uniform sampled two-dimensional spectra, multi-dimensional decomposition...

  9. Analysis of single blow effectiveness in non-uniform parallel plate regenerators

    DEFF Research Database (Denmark)

    Jensen, Jesper Buch; Bahl, Christian Robert Haffenden; Engelbrecht, Kurt

    2011-01-01

    Non-uniform distributions of plate spacings in parallel plate regenerators have been found to induce loss of performance. In this paper, it has been investigated how variations of three geometric parameters (the aspect ratio, the porosity, and the standard deviation of the plate spacing) affects...

  10. [Study of the influence of uniform transverse magnetic field on the dose distribution of high energy electron beam using Monte Carlo method].

    Science.gov (United States)

    You, Shihu; Xu, Yun; Wu, Zhangwen; Hou, Qing; Guo, Chengjun

    2014-12-01

    In the present work, Monte Carlo simulations were employed to study the characteristics of the dose distribution of high energy electron beam in the presence of uniform transverse magnetic field. The simulations carried out the transport processes of the 30 MeV electron beam in the homogeneous water phantom with different magnetic field. It was found that the dose distribution of the 30 MeV electron beam had changed significantly because of the magnetic field. The result showed that the range of the electron beam was decreased obviously and it formed a very high dose peak at the end of the range, and the ratio of maximum dose to the dose of the surface was greatly increased. The results of this study demonstrated that we could change the depth dose distribution of electron beam which is analogous to the heavy ion by modulating the energy of the electron and magnetic field. It means that using magnetic fields in conjunction with electron radiation therapy has great application prospect, but it also has brought new challenges for the research of dose algorithm.

  11. Three-dimensional reconstruction of a radionuclide distribution within a medium of uniform coefficient of attenuation

    International Nuclear Information System (INIS)

    Diaz, J.E.

    1982-01-01

    The non-invasive, fully three-dimensional reconstruction of a radionuclide distribution is studied. The problem is considered in ideal form. Several solutions, ranging from the completely analytical to the completely graphical, are presented for both the non-attenuated and uniformly attenuated cases. A function is defined which, if enacted as a response to each detected photon, will yield, upon superposition, a faithful reconstruction of the radionuclide density. Two and three-dimensional forms of this functions are defined for both the non-attenuated and uniformly attenuated case

  12. SHIELDING OF A UNIFORM ALTERNATING MAGNETIC FIELD USING A CIRCULAR PASSIVE LOOP

    Directory of Open Access Journals (Sweden)

    V. S. Grinchenko

    2015-04-01

    Full Text Available The magnetic and electromagnetic shields are used to reduce the magnetic field in local spaces. Usually these shields are implemented in the form of a box or a cylinder. At the same time the magnetic field reduction in local spaces by means of passive loops is not considered in detail yet. So, the present study considers shielding capabilities of a circular passive loop. The authors have performed an analytical and numerical modeling of a process of a uniform harmonic magnetic field shielding. The simulated results permit to find out the spatial distribution of the shielded magnetic field. Dependencies of shielding effectiveness on the passive loop radius and cross-section are determined. Moreover, the non-monotonic behavior of the loop radius dependence is shown. We have substantiated that the shielded volume of a circular passive loop is advisable to limit by the sphere with a half loop radius. Presented results give parameters of the circular passive loop that reduces the rms value of the magnetic flux density by 30 %.

  13. Correction of experimental photon pencil-beams for the effects of non-uniform and non-parallel measurement conditions

    International Nuclear Information System (INIS)

    Ceberg, Crister P.; Bjaerngard, Bengt E.

    1995-01-01

    An approximate experimental determination of photon pencil-beams can be based on the reciprocity theorem. The scatter part of the pencil-beam is then essentially the derivative with respect to the field radius of measured scatter-to-primary ratios in circular fields. Obtained in this way, however, the pencil-beam implicitly carries the influence from the lateral fluence and beam quality variations of the incident photons, as well as the effects of the divergence of the beam. In this work we show how these effects can be corrected for. The procedure was to calculate scatter-to-primary ratios using an analytical expression for the pencil-beam. By disregarding one by one the effects of the divergence and the fluence and beam quality variations, the influence of these effects were separated and quantified. For instance, for a 6 MV beam of 20x20 cm 2 field size, at 20 cm depth and a source distance of 100 cm, the total effect was 3.9%; 2.0% was due to the non-uniform incident profile, 1.0% due to the non-uniform beam quality, and 0.9% due to the divergence of the beam. At a source distance of 400 cm, all these effects were much lower, adding up to a total of 0.3 %. Using calculated correction factors like these, measured scatter-to-primary ratios were then stripped from the effects of non-uniform and non-parallel measurement conditions, and the scatter part of the pencil-beam was determined using the reciprocity theorem without approximations

  14. Non-uniformly sampled grids in double pole coordinate system for freeform reflector construction

    Science.gov (United States)

    Ma, Donglin; Pacheco, Shaun; Feng, Zexin; Liang, Rongguang

    2015-08-01

    We propose a new method to design freeform reflectors by nonuniformly sampling the source intensity distribution in double pole coordinate system. In double pole coordinate system, there is no pole for the whole hemisphere because both poles of the spherical coordinate system are moved to southernmost point of the sphere and overlapped together. With symmetric definition of both angular coordinates in the modified double pole coordinate system, a better match between the source intensity distribution and target irradiance distribution can be achieved for reflectors with large acceptance solid angle, leading to higher light efficiency and better uniformity on the target surface. With non-uniform sampling of the source intensity, we can design circular freeform reflector to obtain uniform rectangular illumination pattern. Aided by the feedback optimization, the freeform reflector can achieve the collection efficiency for ideal point source over 0.7 and relative standard deviation (RSD) less than 0.1.

  15. Exploring field-of-view non-uniformities produced by a hand-held spectroradiometer

    Directory of Open Access Journals (Sweden)

    Tamir Caras

    2011-01-01

    Full Text Available The shape of a spectroradiometer’s field of view (FOV affects the way spectral measurements are acquired. Knowing this property is a prerequisite for the correct use of the spectrometer. If the substrate is heterogeneous, the ability to accurately know what is being measured depends on knowing the FOV location, shape, spectral and spatial sensitivity. The GER1500 is a hand-held spectrometer with a fixed lens light entry slit and has a laser guide that allows control over the target by positioning the entire unit. In the current study, the FOV of the GER1500 was mapped and analysed. The spectral and spatial non-uniformities of the FOV were examined and were found to be spectrally independent. The relationship between the FOV and the built-in laser guide was tested and found to have a linear displacement dependent on the distance to the target. This allows an accurate prediction of the actual FOV position. A correction method to improve the agreement between the expected and measured reflectance over heterogeneous targets was developed and validated. The methods described are applicable and may be of use with other hand-held spectroradiometers.

  16. Stable and efficient retrospective 4D-MRI using non-uniformly distributed quasi-random numbers

    Science.gov (United States)

    Breuer, Kathrin; Meyer, Cord B.; Breuer, Felix A.; Richter, Anne; Exner, Florian; Weng, Andreas M.; Ströhle, Serge; Polat, Bülent; Jakob, Peter M.; Sauer, Otto A.; Flentje, Michael; Weick, Stefan

    2018-04-01

    The purpose of this work is the development of a robust and reliable three-dimensional (3D) Cartesian imaging technique for fast and flexible retrospective 4D abdominal MRI during free breathing. To this end, a non-uniform quasi random (NU-QR) reordering of the phase encoding (k y –k z ) lines was incorporated into 3D Cartesian acquisition. The proposed sampling scheme allocates more phase encoding points near the k-space origin while reducing the sampling density in the outer part of the k-space. Respiratory self-gating in combination with SPIRiT-reconstruction is used for the reconstruction of abdominal data sets in different respiratory phases (4D-MRI). Six volunteers and three patients were examined at 1.5 T during free breathing. Additionally, data sets with conventional two-dimensional (2D) linear and 2D quasi random phase encoding order were acquired for the volunteers for comparison. A quantitative evaluation of image quality versus scan times (from 70 s to 626 s) for the given sampling schemes was obtained by calculating the normalized mutual information (NMI) for all volunteers. Motion estimation was accomplished by calculating the maximum derivative of a signal intensity profile of a transition (e.g. tumor or diaphragm). The 2D non-uniform quasi-random distribution of phase encoding lines in Cartesian 3D MRI yields more efficient undersampling patterns for parallel imaging compared to conventional uniform quasi-random and linear sampling. Median NMI values of NU-QR sampling are the highest for all scan times. Therefore, within the same scan time 4D imaging could be performed with improved image quality. The proposed method allows for the reconstruction of motion artifact reduced 4D data sets with isotropic spatial resolution of 2.1  ×  2.1  ×  2.1 mm3 in a short scan time, e.g. 10 respiratory phases in only 3 min. Cranio-caudal tumor displacements between 23 and 46 mm could be observed. NU-QR sampling enables for stable 4D

  17. Many-junction photovoltaic device performance under non-uniform high-concentration illumination

    Science.gov (United States)

    Valdivia, Christopher E.; Wilkins, Matthew M.; Chahal, Sanmeet S.; Proulx, Francine; Provost, Philippe-Olivier; Masson, Denis P.; Fafard, Simon; Hinzer, Karin

    2017-09-01

    A parameterized 3D distributed circuit model was developed to calculate the performance of III-V solar cells and photonic power converters (PPC) with a variable number of epitaxial vertically-stacked pn junctions. PPC devices are designed with many pn junctions to realize higher voltages and to operate under non-uniform illumination profiles from a laser or LED. Performance impacts of non-uniform illumination were greatly reduced with increasing number of junctions, with simulations comparing PPC devices with 3 to 20 junctions. Experimental results using Azastra Opto's 12- and 20-junction PPC illuminated by an 845 nm diode laser show high performance even with a small gap between the PPC and optical fiber output, until the local tunnel junction limit is reached.

  18. Alternative methods for evaluation of non-uniformity in nuclear medicine images

    International Nuclear Information System (INIS)

    Rasaneh, S.; Rajabi, H.; Hajizadeh, E.

    2005-01-01

    Non-uniformity test is the most essential in daily quality control procedures of nuclear medicine equipment's. However, the calculation of non-uniformity is hindered due to high level of noise in nuclear medicine data. Non-uniformity may be considered as a type of systematic error while noise is certainly a random error. The present methods of uniformity evaluation are not able to distinguish between systematic and random error and therefore produce incorrect results when noise is significant. In the present study, two hypothetical methods have been tested for evaluation of non-uniformity in nuclear medicine images. Materials and Methods: Using the Monte Carlo method, uniform and non-uniform flood images of different matrix sizes and different counts were generated. The uniformity of the images was calculated using the conventional method and proposed methods. The results were compared with the known non-uniformity data of simulated images. Results: It was observed that the value of integral uniformity never went below the recommended values except in small matrix size of high counts (more than 80 millions counts). The differential uniformity was quite insensitive to the degree of non-uniformity in large matrix size. Matrix size of 64*64 was only found to be suitable for the calculation of differential uniformity. It was observed that in uniform images, a small amount of non-uniformity changes the p-value of Kolmogorov-Smirnov test and noise amplitude of fast fourier transformation test significantly while the conventional methods failed to detect the nonuniformity. Conclusion: The conventional methods do not distinguish noise, which is always present in the data and occasional non-uniformity at low count density. In a uniform intact flood image, the difference between maximum and minimum pixel count (the value of integral uniformity) is much more than the recommended values for non-uniformity. After filtration of image, this difference decreases, but remains high

  19. On The Dynamic Analysis of Non-Uniform Beams Under Uniformly ...

    African Journals Online (AJOL)

    ... the non-uniform continuous beam was replaced by a non-continuous (discrete) system made up of beam elements. The modified elemental and overall stiffness, and mass matrices, the elemental and overall centripetal acceleration matrices as well as the load vector were derived. Next, the Newmark's direct integration ...

  20. The magneto-optical properties of non-uniform graphene nanoribbons

    Science.gov (United States)

    Chung, Hsien-Ching; Lin, Ming-Fa

    2015-03-01

    When synthesizing few-layer graphene nanoribbons (GNRs), non-uniform GNRs would be made simultaneously. Recently, the non-uniform GNRs, which is a stack of two GNRs with unequal widths, have been fabricated by mechanically exfoliated from bulk graphite. Some theoretical predictions have been reported, such as gap opening and transport properties. Under the influence of magnetic fields, magnetic quantization takes place and drastically changes the electronic properties. By tuning the geometric configuration, four categories of magneto-electronic spectra are exhibited. (1) The spectrum is mostly contributed by quasi-Landau levels (QLLs) of monolayer GNRs. (2) The spectrum displays two groups of QLLs, and the non-uniform GNR behaves like a bilayer one. (3) An intermediate category, the spectrum is composite disordered. (4) The spectrum presents the coexistence of monolayer and bilayer spectra. In this work, the magneto-electronic and optical properties for different geometric configurations are given, such as energy dispersions, density of states, wave functions, and magneto-absorption spectra are presented. Furthermore, the transformation between monolayer and bilayer spectra as well as the coexistence of monolayer and bilayer spectra are discussed in detail. One of us (Hsien-Ching Chung) thanks Ming-Hui Chung and Su-Ming Chen for financial support. This work was supported in part by the National Science Council of Taiwan under Grant Number 98-2112-M-006-013-MY4.

  1. Tunable pinning effects produced by non-uniform antidot arrays in YBCO thin films

    Energy Technology Data Exchange (ETDEWEB)

    George, J.; Jones, A.; Al-Qurainy, M. [Institute for Superconducting and Electronic Materials, University of Wollongong, NSW (Australia); Fedoseev, S.A. [Institute for Superconducting and Electronic Materials, University of Wollongong, NSW (Australia); Centre for Medical Radiation Physics, University of Wollongong, NSW (Australia); Rosenfeld, A. [Centre for Medical Radiation Physics, University of Wollongong, NSW (Australia); Pan, A.V. [Institute for Superconducting and Electronic Materials, University of Wollongong, NSW (Australia); National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation)

    2017-04-15

    Uniform, graded and spaced arrays of 3 μm triangular antidots in pulsed laser deposited YBa{sub 2}Cu{sub 3}O{sub 7} (YBCO) superconducting thin films are compared by examining the improvements in the critical current density J{sub c} they produced. The comparison is made to establish the role of their lithographically defined (non-)uniformity and the effectiveness to control and/or enhance the critical current density. It is found that almost all types of non-uniform arrays, including graded ones enhance J{sub c} over the broad applied magnetic field and temperature range due to the modified critical state. Whereas uniform arrays of antidots either reduce or produce no effect on J{sub c} compared to the original (as-deposited) thin films. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  2. Liquid jets injected into non-uniform crossflow

    Science.gov (United States)

    Tambe, Samir

    An experimental study has been conducted with liquid jets injected transversely into a crossflow to study the effect of non-uniformities in the crossflow velocity distribution to the jet behavior. Two different non-uniform crossflows were created during this work, a shear-laden crossflow and a swirling crossflow. The shear-laden crossflow was generated by merging two independent, co-directional, parallel airstreams creating a shear mixing layer at the interface between them. The crossflow exhibited a quasi-linear velocity gradient across the height of the test chamber. By varying the velocities of the two airstreams, the sense and the slope of the crossflow velocity gradient could be changed. Particle Image Velocimetry (PIV) studies were conducted to characterize the crossflow. The parameter, UR, is defined as the ratio of the velocities of the two streams and governs the velocity gradient. A positive velocity gradient was observed for UR > 1 and a negative velocity gradient for UR Phase Doppler Particle Anemometry (PDPA) studies were conducted to study the penetration and atomization of 0.5 mm diameter water jets injected into this crossflow. The crossflow velocity gradient was observed to have a significant effect on jet penetration as well as the post breakup spray. For high UR (> 1), jet penetration increased and the Sauter Mean Diameter (SMD) distribution became more uniform. For low UR (Doppler Velocimetry (LDV) was used to study the crossflow velocities. The axial (Ux) and the tangential (Utheta) components of the crossflow velocity were observed to decrease with increasing radial distance away from the centerbody. The flow angle of the crossflow was smaller than the vane exit angle, with the difference increasing with the vane exit angle. Water jets were injected from a 0.5 mm diameter orifice located on a cylindrical centerbody. Multi-plane PIV measurements were conducted to study the penetration and droplet velocity distribution of the jets. The jets were

  3. A method to measure the mean thickness and non-uniformity of non-uniform thin film by alpha-ray thickness gauge

    International Nuclear Information System (INIS)

    Miyahara, Hiroshi; Yoshida, Makoto; Watanabe, Tamaki

    1977-01-01

    The α-ray thickness gauge is used to measure non-destructively the thicknesses of thin films, and up to the present day, a thin film with uniform thickness is only taken up as the object of α-ray thickness gauge. When the thickness is determined from the displacement between the absorption curves in the presence and absence of thin film, the absorption curve must be displaced in parallel. When many uniform particles were dispersed as sample, the shape of the absorption curve was calculated as the sum of many absorption curves corresponding to the thin films with different thicknesses. By the comparison of the calculated and measured absorption curves, the number of particles, or the mean superficial density can be determined. This means the extension of thickness measurement from uniform to non-uniform films. Furthermore, these particle models being applied to non-uniform thin film, the possibility of measuring the mean thickness and non-uniformity was discussed. As the result, if the maximum difference of the thickness was more than 0.2 mg/cm 2 , the nonuniformity was considered to distinguish by the usual equipment. In this paper, an α-ray thickness gauge using the absorption curve method was treated, but one can apply this easily to an α-ray thickness gauge using α-ray energy spectra before and after the penetration of thin film. (auth.)

  4. Spatial model of the gecko foot hair: functional significance of highly specialized non-uniform geometry.

    Science.gov (United States)

    Filippov, Alexander E; Gorb, Stanislav N

    2015-02-06

    One of the important problems appearing in experimental realizations of artificial adhesives inspired by gecko foot hair is so-called clusterization. If an artificially produced structure is flexible enough to allow efficient contact with natural rough surfaces, after a few attachment-detachment cycles, the fibres of the structure tend to adhere one to another and form clusters. Normally, such clusters are much larger than original fibres and, because they are less flexible, form much worse adhesive contacts especially with the rough surfaces. Main problem here is that the forces responsible for the clusterization are the same intermolecular forces which attract fibres to fractal surface of the substrate. However, arrays of real gecko setae are much less susceptible to this problem. One of the possible reasons for this is that ends of the seta have more sophisticated non-uniformly distributed three-dimensional structure than that of existing artificial systems. In this paper, we simulated three-dimensional spatial geometry of non-uniformly distributed branches of nanofibres of the setal tip numerically, studied its attachment-detachment dynamics and discussed its advantages versus uniformly distributed geometry.

  5. Uniform field loop-gap resonator and rectangular TEU02 for aqueous sample EPR at 94 GHz

    Science.gov (United States)

    Sidabras, Jason W.; Sarna, Tadeusz; Mett, Richard R.; Hyde, James S.

    2017-09-01

    In this work we present the design and implementation of two uniform-field resonators: a seven-loop-six-gap loop-gap resonator (LGR) and a rectangular TEU02 cavity resonator. Each resonator has uniform-field-producing end-sections. These resonators have been designed for electron paramagnetic resonance (EPR) of aqueous samples at 94 GHz. The LGR geometry employs low-loss Rexolite end-sections to improve the field homogeneity over a 3 mm sample region-of-interest from near-cosine distribution to 90% uniform. The LGR was designed to accommodate large degassable Polytetrafluorethylen (PTFE) tubes (0.81 mm O.D.; 0.25 mm I.D.) for aqueous samples. Additionally, field modulation slots are designed for uniform 100 kHz field modulation incident at the sample. Experiments using a point sample of lithium phthalocyanine (LiPC) were performed to measure both the uniformity of the microwave magnetic field and 100 kHz field modulation, and confirm simulations. The rectangular TEU02 cavity resonator employs over-sized end-sections with sample shielding to provide an 87% uniform field for a 0.1 × 2 × 6 mm3 sample geometry. An evanescent slotted window was designed for light access to irradiate 90% of the sample volume. A novel dual-slot iris was used to minimize microwave magnetic field perturbations and maintain cross-sectional uniformity. Practical EPR experiments using the application of light irradiated rose bengal (4,5,6,7-tetrachloro-2‧,4‧,5‧,7‧-tetraiodofluorescein) were performed in the TEU02 cavity. The implementation of these geometries providing a practical designs for uniform field resonators that continue resonator advancements towards quantitative EPR spectroscopy.

  6. New reversing freeform lens design method for LED uniform illumination with extended source and near field

    Science.gov (United States)

    Zhao, Zhili; Zhang, Honghai; Zheng, Huai; Liu, Sheng

    2018-03-01

    In light-emitting diode (LED) array illumination (e.g. LED backlighting), obtainment of high uniformity in the harsh condition of the large distance height ratio (DHR), extended source and near field is a key as well as challenging issue. In this study, we present a new reversing freeform lens design algorithm based on the illuminance distribution function (IDF) instead of the traditional light intensity distribution, which allows uniform LED illumination in the above mentioned harsh conditions. IDF of freeform lens can be obtained by the proposed mathematical method, considering the effects of large DHR, extended source and near field target at the same time. In order to prove the claims, a slim direct-lit LED backlighting with DHR equal to 4 is designed. In comparison with the traditional lenses, illuminance uniformity of LED backlighting with the new lens increases significantly from 0.45 to 0.84, and CV(RMSE) decreases dramatically from 0.24 to 0.03 in the harsh condition. Meanwhile, luminance uniformity of LED backlighting with the new lens is obtained as high as 0.92 at the condition of extended source and near field. This new method provides a practical and effective way to solve the problem of large DHR, extended source and near field for LED array illumination.

  7. Non-uniform approximations for sums of discrete m-dependent random variables

    OpenAIRE

    Vellaisamy, P.; Cekanavicius, V.

    2013-01-01

    Non-uniform estimates are obtained for Poisson, compound Poisson, translated Poisson, negative binomial and binomial approximations to sums of of m-dependent integer-valued random variables. Estimates for Wasserstein metric also follow easily from our results. The results are then exemplified by the approximation of Poisson binomial distribution, 2-runs and $m$-dependent $(k_1,k_2)$-events.

  8. A non-uniform expansion mechanical safety model of the stent.

    Science.gov (United States)

    Yang, J; Huang, N; Du, Q

    2009-01-01

    Stents have a serial unstable structure that readily leads to non-uniform expansion. Non-uniform expansion in turn creates a stent safety problem. We explain how a stent may be simplified to a serial unstable structure, and present a method to calculate the non-uniform expansion of the stent on the basis of the serial unstable structure. We propose a safety criterion based on the expansion displacement instead of the strain, and explain that the parameter Rd, the ratio of the maximum displacement of the elements to normal displacement, is meaningful to assess the safety level of the stent. We also examine how laser cutting influences non-uniform expansion. The examples illustrate how to calculate the parameter Rd to assess non-uniform expansion of the stent, and demonstrate how the laser cutting offset and strengthening coefficient of the material influence the stent expansion behaviour. The methods are valuable for assessing stent safety due to non-uniform expansion.

  9. Classical understanding of electron vortex beams in a uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Han, Yeong Deok [Department of Computer Science and Engineering, Woosuk University, Wanju, Cheonbuk, 565-701 (Korea, Republic of); Choi, Taeseung, E-mail: tschoi@swu.ac.kr [Division of Applied Food System, College of Natural Science, Seoul Women' s University, Seoul 139-774 (Korea, Republic of); School of Computational Sciences, Korea Institute for Advanced Study, Seoul 130-012 (Korea, Republic of)

    2017-04-25

    Recently, interesting observations on electron vortex beams have been made. We propose a classical model that shows vortex-like motion due to suitably-synchronized motion of each electron's cyclotron motion in a uniform magnetic field. It is shown that some basic features of electron vortex beams in a uniform magnetic field, such as azimuthal currents, the relation between energy and kinetic angular momentum, and the parallel-axis theorem are understandable by using this classical model. We also show that the time-dependence of kinetic angular momentum of electron vortex beams could be understood as an effect of a specific nonuniform distribution of classical electrons. - Highlights: • A classical model for electron vortex beams is proposed. • The basic features of azimuthal currents could be understood by using this model. • The kinetic angular momentum of electron vortex beams is intuitively understandable.

  10. On a Generalisation of Uniform Distribution and its Properties

    Directory of Open Access Journals (Sweden)

    K. Jayakumar

    2016-03-01

    Full Text Available Nadarajah et al.(2013 introduced a family life time models using truncated negative binomial distribution and derived some properties of the family of distributions. It is a generalization of Marshall-Olkin family of distributions. In this paper, we introduce Generalized Uniform Distribution (GUD using the approach of Nadarajah et al.(2013. The shape properties of density function and hazard function are discussed. The expression for moments, order statistics, entropies are obtained. Estimation procedure is also discussed.The GDU introduced here is a generalization of the Marshall-Olkin extended uniform distribution studied in Jose and Krishna(2011.

  11. Efficient SPECT scatter calculation in non-uniform media using correlated Monte Carlo simulation

    International Nuclear Information System (INIS)

    Beekman, F.J.

    1999-01-01

    Accurate simulation of scatter in projection data of single photon emission computed tomography (SPECT) is computationally extremely demanding for activity distribution in non-uniform dense media. This paper suggests how the computation time and memory requirements can be significantly reduced. First the scatter projection of a uniform dense object (P SDSE ) is calculated using a previously developed accurate and fast method which includes all orders of scatter (slab-derived scatter estimation), and then P SDSE is transformed towards the desired projection P which is based on the non-uniform object. The transform of P SDSE is based on two first-order Compton scatter Monte Carlo (MC) simulated projections. One is based on the uniform object (P u ) and the other on the object with non-uniformities (P ν ). P is estimated by P-tilde=P SDSE P ν /P u . A tremendous decrease in noise in P-tilde is achieved by tracking photon paths for P ν identical to those which were tracked for the calculation of P u and by using analytical rather than stochastic modelling of the collimator. The method was validated by comparing the results with standard MC-simulated scatter projections (P) of 99m Tc and 201 Tl point sources in a digital thorax phantom. After correction, excellent agreement was obtained between P-tilde and P. The total computation time required to calculate an accurate scatter projection of an extended distribution in a thorax phantom on a PC is a only few tens of seconds per projection, which makes the method attractive for application in accurate scatter correction in clinical SPECT. Furthermore, the method removes the need of excessive computer memory involved with previously proposed 3D model-based scatter correction methods. (author)

  12. Numerical study of chaotic oscillations in the electron beam with virtual cathode in the external non-uniform magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Hramov, Alexander E., E-mail: aeh@nonlin.sgu.r [Faculty of Nonlinear Processes, Saratov State University, 83, Astrakhanskaya, Saratov, 410012 (Russian Federation); Koronovskii, Alexey A., E-mail: alkor@nonlin.sgu.r [Faculty of Nonlinear Processes, Saratov State University, 83, Astrakhanskaya, Saratov, 410012 (Russian Federation); Kurkin, Semen, E-mail: KurkinSA@nonlin.sgu.r [Faculty of Nonlinear Processes, Saratov State University, 83, Astrakhanskaya, Saratov, 410012 (Russian Federation)

    2010-07-05

    In this Letter the results of theoretical investigations of the chaotic microwave oscillator based on the electron beam with a virtual cathode are presented. Nonlinear non-stationary processes in these electron systems are studied by means of numerical analysis of 2.5D model. It was discovered that the non-uniform external magnetic field value controls the dynamical regime of oscillations in the virtual cathode oscillator. The processes of the chaotization of output microwave radiation are described and interpreted from the point of view of the formation and interaction of electron structures (bunches) in the electron beams. The numerical results have shown that the investigated electron system with virtual cathode could be considered as a promising controlled source of wideband chaotic oscillations in the microwave range.

  13. Errors due to non-uniform distribution of fat in dual X-ray absorptiometry of the lumbar spine

    International Nuclear Information System (INIS)

    Tothill, P.; Pye, D.W.

    1992-01-01

    Errors in spinal dual X-ray absorptiometry (DXA) were studied by analysing X-ray CT scans taken for diagnostic purposes on 20 patients representing a wide range of fat content. The mean difference between the fat thickness over the vertebral bodies and that over a background area in antero-posterior (AP) scanning was 6.7 ± 8.1 mm for men and 13.4 ± 4.7 mm for women. For AP scanning a non-uniform fat distribution leads to a mean overestimate of 0.029 g/cm 2 for men and 0.057 g/cm 2 for women. The error exceeded 0.1 g/cm 2 in 10% of slices. For lateral scanning the error exceeded 0.1 g/cm 2 (about 15% of normal) in a quarter of slices. (author)

  14. Real-time definition of non-randomness in the distribution of genomic events.

    Directory of Open Access Journals (Sweden)

    Ulrich Abel

    Full Text Available Features such as mutations or structural characteristics can be non-randomly or non-uniformly distributed within a genome. So far, computer simulations were required for statistical inferences on the distribution of sequence motifs. Here, we show that these analyses are possible using an analytical, mathematical approach. For the assessment of non-randomness, our calculations only require information including genome size, number of (sampled sequence motifs and distance parameters. We have developed computer programs evaluating our analytical formulas for the real-time determination of expected values and p-values. This approach permits a flexible cluster definition that can be applied to most effectively identify non-random or non-uniform sequence motif distribution. As an example, we show the effectivity and reliability of our mathematical approach in clinical retroviral vector integration site distribution.

  15. Evaluation of the Analytical Anisotropic Algorithm (AAA) in dose calculation for fields with non-uniform fluences considering heterogeneity correction; Avaliacao do Algoritmo Analitico Anisotropico (AAA) no calculo de dose para campos com fluencia nao uniforme considerando correcao de heterogeneidade

    Energy Technology Data Exchange (ETDEWEB)

    Bornatto, P.; Funchal, M.; Bruning, F.; Toledo, H.; Lyra, J.; Fernandes, T.; Toledo, F.; Marciao, C., E-mail: pricila_bornatto@yahoo.com.br [Hospital Erasto Gaertner (LPCC), Curitiba, PR (Brazil). Departamento de Radioterapia

    2014-08-15

    The purpose of this study is to evaluate the calculation of dose distribution AAA (Varian Medical Systems) for fields with non-uniform fluences considering heterogeneity correction. Five different phantoms were used with different density materials. These phantoms were scanned in the CT BrightSpeed (©GE Healthcare) upon the array of detectors MAPCHECK2 TM (Sun Nuclear Corporation) and irradiated in a linear accelerator 600 CD (Varian Medical Systems) 6MV and rate dose 400MU/min with isocentric setup. The fluences used were exported from IMRT plans, calculated by ECLIPSE™ planning system (Varian Medical Systems), and a 10x10 cm{sup 2} field to assess the heterogeneity correction for uniform fluence. The measured dose distribution was compared to the calculated by Gamma analysis with approval criteria of 3% / 3 mm and 10% threshold. The evaluation was performed using the software SNCPatient (Sun Nuclear Corporation) and considering absolute dose normalized at maximum. The phantoms best performers were those with low density materials, with an average of 99.2% approval. Already phantoms with plates of higher density material presented various fluences below 95% of the points approved. The average value reached 94.3%. It was observed a dependency between fluency and approved percentage points, whereas for the same fluency, 100% of the points have been approved in all phantoms. The approval criteria for IMRT plans recommended in most centers is 3% / 3mm with at least 95% of points approved, it can be concluded that, under these conditions, the IMRT plans with heterogeneity correction can be performed , however the quality control must be careful because the difficulty of the system to accurately predict the dose distribution in certain situations. (author)

  16. Non-uniformity Correction of Infrared Images by Midway Equalization

    Directory of Open Access Journals (Sweden)

    Yohann Tendero

    2012-07-01

    Full Text Available The non-uniformity is a time-dependent noise caused by the lack of sensor equalization. We present here the detailed algorithm and on line demo of the non-uniformity correction method by midway infrared equalization. This method was designed to suit infrared images. Nevertheless, it can be applied to images produced for example by scanners, or by push-broom satellites. The obtained single image method works on static images, is fully automatic, having no user parameter, and requires no registration. It needs no camera motion compensation, no closed aperture sensor equalization and is able to correct for a fully non-linear non-uniformity.

  17. Thermoelastic analysis of non-uniform pressurized functionally graded cylinder with variable thickness using first order shear deformation theory(FSDT) and perturbation method

    Science.gov (United States)

    Khoshgoftar, M. J.; Mirzaali, M. J.; Rahimi, G. H.

    2015-11-01

    Recently application of functionally graded materials(FGMs) have attracted a great deal of interest. These materials are composed of various materials with different micro-structures which can vary spatially in FGMs. Such composites with varying thickness and non-uniform pressure can be used in the aerospace engineering. Therefore, analysis of such composite is of high importance in engineering problems. Thermoelastic analysis of functionally graded cylinder with variable thickness under non-uniform pressure is considered. First order shear deformation theory and total potential energy approach is applied to obtain the governing equations of non-homogeneous cylinder. Considering the inner and outer solutions, perturbation series are applied to solve the governing equations. Outer solution for out of boundaries and more sensitive variable in inner solution at the boundaries are considered. Combining of inner and outer solution for near and far points from boundaries leads to high accurate displacement field distribution. The main aim of this paper is to show the capability of matched asymptotic solution for different non-homogeneous cylinders with different shapes and different non-uniform pressures. The results can be used to design the optimum thickness of the cylinder and also some properties such as high temperature residence by applying non-homogeneous material.

  18. Nanosecond laser texturing of uniformly and non-uniformly wettable micro structured metal surfaces for enhanced boiling heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Zupančič, Matevž, E-mail: matevz.zupancic@fs.uni-lj.si; Može, Matic; Gregorčič, Peter; Golobič, Iztok

    2017-03-31

    Highlights: • Surfaces with periodically changed wettability were produced by a ns marking laser. • Heat transfer was investigated on uniformly and non-uniformly wettable surfaces. • Microporous surfaces with non-uniform wettability enhance boiling heat transfer. • The most bubble nucleations were observed in the vicinity of the microcavities. • Results agree with the predictions of the nucleation criteria. - Abstract: Microstructured uniformly and non-uniformly wettable surfaces were created on 25-μm-thin stainless steel foils by laser texturing using a marking nanosecond Nd:YAG laser (λ = 1064 nm) and utilizing various laser fluences and scan line separations. High-speed photography and high-speed IR thermography were used to investigate nucleate boiling heat transfer on the microstructured surfaces. The most pronounced results were obtained on a surface with non-uniform microstructure and non-uniform wettability. The obtained results show up to a 110% higher heat transfer coefficients and 20–40 times higher nucleation site densities compared to the untextured surface. We show that the number of active nucleation sites is significantly increased in the vicinity of microcavities that appeared in areas with the smallest (10 μm) scan line separation. Furthermore, this confirms the predictions of nucleation criteria and proves that straightforward, cost-effective nanosecond laser texturing allows the production of cavities with diameters of up to a few micrometers and surfaces with non-uniform wettability. Additionally, this opens up important possibilities for a more deterministic control over the complex boiling process.

  19. Desynchronization boost by non-uniform coordinated reset stimulation in ensembles of pulse-coupled neurons

    Science.gov (United States)

    Lücken, Leonhard; Yanchuk, Serhiy; Popovych, Oleksandr V.; Tass, Peter A.

    2013-01-01

    Several brain diseases are characterized by abnormal neuronal synchronization. Desynchronization of abnormal neural synchrony is theoretically compelling because of the complex dynamical mechanisms involved. We here present a novel type of coordinated reset (CR) stimulation. CR means to deliver phase resetting stimuli at different neuronal sub-populations sequentially, i.e., at times equidistantly distributed in a stimulation cycle. This uniform timing pattern seems to be intuitive and actually applies to the neural network models used for the study of CR so far. CR resets the population to an unstable cluster state from where it passes through a desynchronized transient, eventually resynchronizing if left unperturbed. In contrast, we show that the optimal stimulation times are non-uniform. Using the model of weakly pulse-coupled neurons with phase response curves, we provide an approach that enables to determine optimal stimulation timing patterns that substantially maximize the desynchronized transient time following the application of CR stimulation. This approach includes an optimization search for clusters in a low-dimensional pulse coupled map. As a consequence, model-specific non-uniformly spaced cluster states cause considerably longer desynchronization transients. Intriguingly, such a desynchronization boost with non-uniform CR stimulation can already be achieved by only slight modifications of the uniform CR timing pattern. Our results suggest that the non-uniformness of the stimulation times can be a medically valuable parameter in the calibration procedure for CR stimulation, where the latter has successfully been used in clinical and pre-clinical studies for the treatment of Parkinson's disease and tinnitus. PMID:23750134

  20. A 3D numerical simulation of mixed convection of a magnetic nanofluid in the presence of non-uniform magnetic field in a vertical tube using two phase mixture model

    Energy Technology Data Exchange (ETDEWEB)

    Aminfar, Habib, E-mail: hh_aminfar@tabrizu.ac.i [Faculty of Mechanical Engineering, University of Tabriz, Tabriz (Iran, Islamic Republic of); Mohammadpourfard, Mousa, E-mail: Mohammadpour@azaruniv.ed [Department of Mechanical Engineering, Azarbaijan University of Tarbiat Moallem, Tabriz, P.O. Box 53751-71379 (Iran, Islamic Republic of); Narmani Kahnamouei, Yousef, E-mail: Narmani87@ms.tabrizu.ac.i [Faculty of Mechanical Engineering, University of Tabriz, Tabriz (Iran, Islamic Republic of)

    2011-08-15

    In this paper, results of applying a non-uniform magnetic field on a ferrofluid (kerosene and 4 vol% Fe{sub 3}O{sub 4}) flow in a vertical tube have been reported. The hydrodynamics and thermal behavior of the flow are investigated numerically using the two phase mixture model and the control volume technique. Two positive and negative magnetic field gradients have been examined. Based on the obtained results the Nusselt number can be controlled externally using the magnetic field with different intensity and gradients. It is concluded that the magnetic field with negative gradient acts similar to Buoyancy force and augments the Nusselt number, while the magnetic field with positive gradient decreases it. Also with the negative gradient of the magnetic field, pumping power increases and vice versa for the positive gradient case. - Highlights: We model hydrothermal behavior of a ferrofluid flow using two phase mixture model. Various external non-uniform magnetic fields were implemented in a vertical tube. Nusselt number can be controlled using the magnetic field with different gradients. The magnetic field is more effective in low Reynolds numbers. Heat transfer enhancement using the magnetic field needs high pumping power.

  1. Non-uniform sampling and wide range angular spectrum method

    International Nuclear Information System (INIS)

    Kim, Yong-Hae; Byun, Chun-Won; Oh, Himchan; Lee, JaeWon; Pi, Jae-Eun; Heon Kim, Gi; Lee, Myung-Lae; Ryu, Hojun; Chu, Hye-Yong; Hwang, Chi-Sun

    2014-01-01

    A novel method is proposed for simulating free space field propagation from a source plane to a destination plane that is applicable for both small and large propagation distances. The angular spectrum method (ASM) was widely used for simulating near field propagation, but it caused a numerical error when the propagation distance was large because of aliasing due to under sampling. Band limited ASM satisfied the Nyquist condition on sampling by limiting a bandwidth of a propagation field to avoid an aliasing error so that it could extend the applicable propagation distance of the ASM. However, the band limited ASM also made an error due to the decrease of an effective sampling number in a Fourier space when the propagation distance was large. In the proposed wide range ASM, we use a non-uniform sampling in a Fourier space to keep a constant effective sampling number even though the propagation distance is large. As a result, the wide range ASM can produce simulation results with high accuracy for both far and near field propagation. For non-paraxial wave propagation, we applied the wide range ASM to a shifted destination plane as well. (paper)

  2. Experimental research on the flow field uniformity in the filter house of a nuclear air cleaning system

    International Nuclear Information System (INIS)

    Jiang Feng; Yang Jun; Ye Suisheng

    2000-01-01

    The filter house structure is designed using similarity laws showing that the filter house structure causes a non-uniform flow field. The flow field is also measured experimentally. The air flow field is analyzed for different conditions. The results show that: (1) The HEPA filters affect the dispersion of the air flow; (2) The appropriate angle for air input to the rectifier satisfies the requirements for uniform air flow for the test conditions; (3) The rectifier has little influence on the air flow for operating conditions

  3. Restoration of non-uniform exposure motion blurred image

    Science.gov (United States)

    Luo, Yuanhong; Xu, Tingfa; Wang, Ningming; Liu, Feng

    2014-11-01

    Restoring motion-blurred image is the key technologies in the opto-electronic detection system. The imaging sensors such as CCD and infrared imaging sensor, which are mounted on the motion platforms, quickly move together with the platforms of high speed. As a result, the images become blur. The image degradation will cause great trouble for the succeeding jobs such as objects detection, target recognition and tracking. So the motion-blurred images must be restoration before detecting motion targets in the subsequent images. On the demand of the real weapon task, in order to deal with targets in the complex background, this dissertation uses the new theories in the field of image processing and computer vision to research the new technology of motion deblurring and motion detection. The principle content is as follows: 1) When the prior knowledge about degradation function is unknown, the uniform motion blurred images are restored. At first, the blur parameters, including the motion blur extent and direction of PSF(point spread function), are estimated individually in domain of logarithmic frequency. The direction of PSF is calculated by extracting the central light line of the spectrum, and the extent is computed by minimizing the correction between the fourier spectrum of the blurred image and a detecting function. Moreover, in order to remove the strip in the deblurred image, windows technique is employed in the algorithm, which makes the deblurred image clear. 2) According to the principle of infrared image non-uniform exposure, a new restoration model for infrared blurred images is developed. The fitting of infrared image non-uniform exposure curve is performed by experiment data. The blurred images are restored by the fitting curve.

  4. UOBPRM: A uniformly distributed obstacle-based PRM

    KAUST Repository

    Yeh, Hsin-Yi; Thomas, Shawna; Eppstein, David; Amato, Nancy M.

    2012-01-01

    This paper presents a new sampling method for motion planning that can generate configurations more uniformly distributed on C-obstacle surfaces than prior approaches. Here, roadmap nodes are generated from the intersections between C

  5. Non-uniform tube representation of proteins

    DEFF Research Database (Denmark)

    Hansen, Mikael Sonne

    Treating the full protein structure is often neither computationally nor physically possible. Instead one is forced to consider various reduced models capturing the properties of interest. Previous work have used tubular neighborhoods of the C-alpha backbone. However, assigning a unique radius...... might not correctly capture volume exclusion - of crucial importance when trying to understand a proteins $3$d-structure. We propose a new reduced model treating the protein as a non-uniform tube with a radius reflecting the positions of atoms. The tube representation is well suited considering X......-ray crystallographic resolution ~ 3Å while a varying radius accounts for the different sizes of side chains. Such a non-uniform tube better capture the protein geometry and has numerous applications in structural/computational biology from the classification of protein structures to sequence-structure prediction....

  6. Adding muscle where you need it: non-uniform hypertrophy patterns in elite sprinters.

    Science.gov (United States)

    Handsfield, G G; Knaus, K R; Fiorentino, N M; Meyer, C H; Hart, J M; Blemker, S S

    2017-10-01

    Sprint runners achieve much higher gait velocities and accelerations than average humans, due in part to large forces generated by their lower limb muscles. Various factors have been explored in the past to understand sprint biomechanics, but the distribution of muscle volumes in the lower limb has not been investigated in elite sprinters. In this study, we used non-Cartesian MRI to determine muscle sizes in vivo in a group of 15 NCAA Division I sprinters. Normalizing muscle sizes by body size, we compared sprinter muscles to non-sprinter muscles, calculated Z-scores to determine non-uniformly large muscles in sprinters, assessed bilateral symmetry, and assessed gender differences in sprinters' muscles. While limb musculature per height-mass was 22% greater in sprinters than in non-sprinters, individual muscles were not all uniformly larger. Hip- and knee-crossing muscles were significantly larger among sprinters (mean difference: 30%, range: 19-54%) but only one ankle-crossing muscle was significantly larger (tibialis posterior, 28%). Population-wide asymmetry was not significant in the sprint population but individual muscle asymmetries exceeded 15%. Gender differences in normalized muscle sizes were not significant. The results of this study suggest that non-uniform hypertrophy patterns, particularly large hip and knee flexors and extensors, are advantageous for fast sprinting. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Finite element analysis of heating a non-mixed liquid with non-uniform solar flux through semi-transparent medium

    International Nuclear Information System (INIS)

    Safdari, Y.B.; Sirivatch Shimpalee

    2000-01-01

    It has been shown in an application [1-3), in a solar flux heating of a liquid through a semi-transparent medium, that the far side of the medium receiving solar radiation achieves a higher temperature than the side receiving radiation. In this work, a two-dimensional transient finite element analysis of concentrated solo flux heating of a non-mixed liquid through a semi-transparent medium (such as glass) is carried out. The radiation heat flux is provided by a paraboloidal concentrator which focuses a non-uniform flux on the receiver. Realistic boundary conditions are considered to analyse the heat transfer problem to study the transient temperature distribution in the medium. The effects of a non-mixed liquid and a non-uniform flux show dramatic differences between the present work and the previous works [1-31. A non-mixed liquid causes greater temperature difference in the glass in both radial and axial direction than a mixed liquid used in the previous analysis. Therminol-55 is used as heated liquid for lower flux case, and sodium is used for high flux. The effect of the conductivity difference between the two liquids is studied. Results show that in the case of Therminol-55, the temperature of the liquid-side glass is much higher than that of the sodium case. The temperature distribution will be used to analyse the thermal stresses in the glass to see if fracture will occurs [4) in the glass. (Author)

  8. Optimal distribution of temperature points in μSR measurement of local field

    International Nuclear Information System (INIS)

    Pełka, R.; Zieliński, P.M.; Konieczny, P.; Wasiutyński, T.

    2013-01-01

    Three possible distributions of temperature points in the μSR measurement of local field (order parameter) are discussed. The least square method is applied to estimate the scale of the deviations of the fitted parameters from the true values. It indicates that the distribution corresponding to a uniform section of the order parameter values (uniform-in-signal) incurs the smallest errors. The distribution constructed on the basis of the zeros of the Chebyshev polynomials yields comparable uncertainties, while the uniform-in-temperature distribution turns out to be least effective incurring considerably larger errors. These findings can be useful while planning an order parameter measurement in the μSR experiment

  9. Non-uniform distribution pattern for differentially expressed genes of transgenic rice Huahui 1 at different developmental stages and environments.

    Directory of Open Access Journals (Sweden)

    Zhi Liu

    Full Text Available DNA microarray analysis is an effective method to detect unintended effects by detecting differentially expressed genes (DEG in safety assessment of genetically modified (GM crops. With the aim to reveal the distribution of DEG of GM crops under different conditions, we performed DNA microarray analysis using transgenic rice Huahui 1 (HH1 and its non-transgenic parent Minghui 63 (MH63 at different developmental stages and environmental conditions. Considerable DEG were selected in each group of HH1 under different conditions. For each group of HH1, the number of DEG was different; however, considerable common DEG were shared between different groups of HH1. These findings suggested that both DEG and common DEG were adequate for investigation of unintended effects. Furthermore, a number of significantly changed pathways were found in all groups of HH1, indicating genetic modification caused everlasting changes to plants. To our knowledge, our study for the first time provided the non-uniformly distributed pattern for DEG of GM crops at different developmental stages and environments. Our result also suggested that DEG selected in GM plants at specific developmental stage and environment could act as useful clues for further evaluation of unintended effects of GM plants.

  10. Improving the quality factor of an RF spiral inductor with non-uniform metal width and non-uniform coil spacing

    International Nuclear Information System (INIS)

    Shen Pei; Zhang Wanrong; Huang Lu; Jin Dongyue; Xie Hongyun

    2011-01-01

    An improved inductor layout with non-uniform metal width and non-uniform spacing is proposed to increase the quality factor (Q factor). For this inductor layout, from outer coil to inner coil, the metal width is reduced by an arithmetic-progression step, while the metal spacing is increased by a geometric-progression step. An improved layout with variable width and changed spacing is of benefit to the Q factor of RF spiral inductor improvement (approximately 42.86%), mainly due to the suppression of eddy-current loss by weakening the current crowding effect in the center of the spiral inductor. In order to increase the Q factor further, for the novel inductor, a patterned ground shield is used with optimized layout together. The results indicate that, in the range of 0.5 to 16 GHz, the Q factor of the novel inductor is at an optimum, which improves by 67% more than conventional inductors with uniform geometry dimensions (equal width and equal spacing), is enhanced by nearly 23% more than a PGS inductor with uniform geometry dimensions, and improves by almost 20% more than an inductor with an improved layout. (semiconductor devices)

  11. Long GRBs sources population non-uniformity

    Science.gov (United States)

    Arkhangelskaja, Irene

    Long GRBs observed in the very wide energy band. It is possible to separate two subsets of GRBs with high energy component (E > 500 MeV) presence. First type events energy spectra in low and high energy intervals are similar (as for GRB 021008) and described by Band, power law or broken power law models look like to usual bursts without emission in tens MeV region. For example, Band spectrum of GRB080916C covering 6 orders of magnitude. Second ones contain new additional high energy spectral component (for example, GRB 050525B and GRB 090902B). Both types of GRBs observed since CGRO mission beginning. The low energy precursors existence are typical for all types bursts. Both types of bursts temporal profiles can be similar in the various energy regions during some events or different in other cases. The absence of hard to soft evolution in low energy band and (or) presence of high energy precursors for some events are the special features of second class of GRBs by the results of preliminary data analysis and this facts gives opportunities to suppose differences between these two GRBs subsets sources. Also the results of long GRB redshifts distribution analysis have shown its shape contradiction to uniform population objects one for our Metagalaxy to both total and various redshifts definition methods GRBs sources samples. These evidences allow making preliminary conclusion about non-uniformity of long GRBs sources population.

  12. A uniform geometrical optics and an extended uniform geometrical theory of diffraction for evaluating high frequency EM fields near smooth caustics and composite shadow boundaries

    Science.gov (United States)

    Constantinides, E. D.; Marhefka, R. J.

    1994-01-01

    A uniform geometrical optics (UGO) and an extended uniform geometrical theory of diffraction (EUTD) are developed for evaluating high frequency electromagnetic (EM) fields within transition regions associated with a two and three dimensional smooth caustic of reflected rays and a composite shadow boundary formed by the caustic termination or the confluence of the caustic with the reflection shadow boundary (RSB). The UGO is a uniform version of the classic geometrical optics (GO). It retains the simple ray optical expressions of classic GO and employs a new set of uniform reflection coefficients. The UGO also includes a uniform version of the complex GO ray field that exists on the dark side of the smooth caustic. The EUTD is an extension of the classic uniform geometrical theory of diffraction (UTD) and accounts for the non-ray optical behavior of the UGO reflected field near caustics by using a two-variable transition function in the expressions for the edge diffraction coefficients. It also uniformly recovers the classic UTD behavior of the edge diffracted field outside the composite shadow boundary transition region. The approach employed for constructing the UGO/EUTD solution is based on a spatial domain physical optics (PO) radiation integral representation for the fields which is then reduced using uniform asymptotic procedures. The UGO/EUTD analysis is also employed to investigate the far-zone RCS problem of plane wave scattering from two and three dimensional polynomial defined surfaces, and uniform reflection, zero-curvature, and edge diffraction coefficients are derived. Numerical results for the scattering and diffraction from cubic and fourth order polynomial strips are also shown and the UGO/EUTD solution is validated by comparison to an independent moment method (MM) solution. The UGO/EUTD solution is also compared with the classic GO/UTD solution. The failure of the classic techniques near caustics and composite shadow boundaries is clearly

  13. Complete mechanical behavior analysis of FG Nano Beam under non-uniform loading using non-local theory

    Science.gov (United States)

    Ghaffari, I.; Parhizkar Yaghoobi, M.; Ghannad, M.

    2018-01-01

    The purpose of this study is to offer a complete solution to analyze the mechanical behavior (bending, buckling and vibration) of Nano-beam under non-uniform loading. Furthermore, the effects of size (nonlocal parameters), non-homogeneity constants, and different boundary conditions are investigated by using this method. The exact solution presented here reduces costs incurred by experiments. In this research, the displacement field obeys the kinematics of the Euler-Bernoulli beam theory and non-local elasticity theory has been used. The governing equations and general boundary conditions are derived for a beam by using energy method. The presented solution enables us to analyze any kind of loading profile and boundary conditions with no limitations. Furthermore, this solution, unlike previous studies, is not a series-solution; hence, there is no limitation prior to existing with the series-solution, nor does it need to check convergence. Based on the developed analytical solution, the influence of size, non-homogeneity and non-uniform loads on bending, buckling and vibration behaviors is discussed. Also, the obtained result is highly accurate and in good agreement with previous research. In theoretical method, the allowable range for non-local parameters can be determined so as to make a major contribution to the reduction of the cost of experiments determining the value of non-local parameters.

  14. The ciliate Paramecium shows higher motility in non-uniform chemical landscapes.

    Directory of Open Access Journals (Sweden)

    Carl Giuffre

    Full Text Available We study the motility behavior of the unicellular protozoan Paramecium tetraurelia in a microfluidic device that can be prepared with a landscape of attracting or repelling chemicals. We investigate the spatial distribution of the positions of the individuals at different time points with methods from spatial statistics and Poisson random point fields. This makes quantitative the informal notion of "uniform distribution" (or lack thereof. Our device is characterized by the absence of large systematic biases due to gravitation and fluid flow. It has the potential to be applied to the study of other aquatic chemosensitive organisms as well. This may result in better diagnostic devices for environmental pollutants.

  15. Uniform dose compensation using field within a field technique in T-shaped irradiation for esophageal cancer

    International Nuclear Information System (INIS)

    Murakami, Ryuji; Sugahara, Takeshi; Baba, Yuji; Yamashita, Yasuyuki

    2003-01-01

    We devised a uniform compensation method to improve dose distribution using the field within a field technique in T-shaped irradiation for esophageal cancer. Isodose curves and dose volume histograms (DVH) of the esophagus in the treatment volume were examined in ten patients treated for esophageal cancers. For the DVH analysis, the prescription dose was 40 Gy to the center of the treatment volume, and the volume ratio of the esophagus receiving within ±5% of the prescription dose (38-42 Gy) was regarded as an index of dose homogeneity (V±5%). The peak dose in the conventional antero-posterior opposed fields irradiation existed at the clavicular level, and the 90% isodose curve crossing the esophagus almost corresponded to the top level of the aortic arch. When 40 Gy is irradiated, the maximum dose of the esophagus and V±5% were 45.55±0.55 Gy and 59.7±13.2% respectively. The dose distribution of the esophagus became relatively homogeneous when a 10% dose was added using the field within a field technique to the area under the bottom level of the aortic arch, and the maximum dose and V±5% were 42.53±0.94 Gy and 91.7±7.1% respectively. A 10% and more overdose area existed at the clavicular level in the conventional antero-posterior opposed fields irradiation. A relatively homogeneous dose distribution could be obtained using the field within a field technique. (author)

  16. Equivalent (uniform) square field sizes of flattening filter free photon beams

    Science.gov (United States)

    Lechner, Wolfgang; Kuess, Peter; Georg, Dietmar; Palmans, Hugo

    2017-10-01

    Various types of treatment units, such as CyberKnife, TomoTherapy and C-arm linear accelerators (LINACs) are operated using flattening filter free (FFF) photon beams. Their reference dosimetry, however, is currently based on codes of practice that provide data which were primarily developed and tested for high-energy photon beams with flattening filter (WFF). The aim of this work was to introduce equivalent uniform square field sizes of FFF beams to serve as a basis of a unified reference dosimetry procedure applicable to all aforementioned FFF machines. For this purpose, in-house determined experimental data together with published data of the ratio of doses at depths of 20 cm and 10 cm in water (D 20,10) were used to characterize the depth dose distribution of 6 and 10 MV WFF and FFF beams. These data were analyzed for field sizes ranging from 2  ×  2 cm2 to 40  ×  40 cm2. A scatter function that takes the lateral profiles of the individual beams into account was fitted to the experimental data. The lateral profiles of the WFF beams were assumed to be uniform, while those of the FFF beams were approximated using fourth or sixth order polynomials. The scatter functions of the FFF beams were recalculated using a uniform lateral profile (the same as the physical profile of the WFF beams), and are henceforth denoted as virtual uniform FFF beams (VUFFF). The field sizes of the VUFFF beams having the same scatter contribution as the corresponding FFF beams at a given field size were defined as the equivalent uniform square field (EQUSF) size. Data from four different LINACs with 18 different beams in total, as well as a CyberKnife beam, were analyzed. The average values of EQUSFs over all investigated LINACs of the conventional 10  ×  10 cm2 reference fields of 6 MV and 10 MV FFF beams for C-arm LINACs and machine-specific reference fields for CyberKnife and TomoTherapy were 9.5 cm, 9 cm, 5.0 cm and 6.5 cm respectively. The

  17. Simulation of magnetic drug targeting through tracheobronchial airways in the presence of an external non-uniform magnetic field using Lagrangian magnetic particle tracking

    International Nuclear Information System (INIS)

    Pourmehran, O.; Rahimi-Gorji, M.; Gorji-Bandpy, M.; Gorji, T.B.

    2015-01-01

    Drug delivery technologies are an important area within biomedicine. Targeted drug delivery aims to reduce the undesired side effects of drug usage by directing or capturing the active agents near a desired site within the body. Herein, a numerical investigation of magnetic drug targeting (MDT) using aerosol drugs named polystyrene particle (PMS40) in human lung is presented considering one-way coupling on the transport and capture of the magnetic particle. A realistic 3D geometry based on CT scan images is provided for CFD simulation. An external non-uniform magnetic field is applied. Parametric investigation is conducted and the influence of particle diameter, magnetic source position, and magnetic number (Mn) on the deposition efficiency and particle behavior is reported. According to the results, the magnetic field increased deposition efficiency of particles in a target region, the efficiency of deposition and MDT technique has a direct relation with increasing the particle diameter for magnetic number of 1 Tesla (T) and lower (Mn≤1(T)). Also it can be seen that there is an inverse relation between the particle diameter and deposition efficiency when Mn is more than 1 (T). - Highlights: • A realistic 3D geometry of human tracheobronchial airway based on CT scan image. • External non-uniform magnetic field applied to target the magnetic drug career. • Lagrangian particle tracking using discrete phase model applied. • The efficiency of deposition is dependent of magnetic number and particle diameter

  18. Simulation of magnetic drug targeting through tracheobronchial airways in the presence of an external non-uniform magnetic field using Lagrangian magnetic particle tracking

    Energy Technology Data Exchange (ETDEWEB)

    Pourmehran, O., E-mail: oveis87@yahoo.com; Rahimi-Gorji, M.; Gorji-Bandpy, M., E-mail: gorji@nit.ac.ir; Gorji, T.B.

    2015-11-01

    Drug delivery technologies are an important area within biomedicine. Targeted drug delivery aims to reduce the undesired side effects of drug usage by directing or capturing the active agents near a desired site within the body. Herein, a numerical investigation of magnetic drug targeting (MDT) using aerosol drugs named polystyrene particle (PMS40) in human lung is presented considering one-way coupling on the transport and capture of the magnetic particle. A realistic 3D geometry based on CT scan images is provided for CFD simulation. An external non-uniform magnetic field is applied. Parametric investigation is conducted and the influence of particle diameter, magnetic source position, and magnetic number (Mn) on the deposition efficiency and particle behavior is reported. According to the results, the magnetic field increased deposition efficiency of particles in a target region, the efficiency of deposition and MDT technique has a direct relation with increasing the particle diameter for magnetic number of 1 Tesla (T) and lower (Mn≤1(T)). Also it can be seen that there is an inverse relation between the particle diameter and deposition efficiency when Mn is more than 1 (T). - Highlights: • A realistic 3D geometry of human tracheobronchial airway based on CT scan image. • External non-uniform magnetic field applied to target the magnetic drug career. • Lagrangian particle tracking using discrete phase model applied. • The efficiency of deposition is dependent of magnetic number and particle diameter.

  19. Bone-Marrow Stem-Cell Survival in the Non-Uniformly Exposed Mammal

    Energy Technology Data Exchange (ETDEWEB)

    Bond, V. P.; Robinson, C. V. [Brookhaven National Laboratory, Medical Research Center, Upton, Long Island, NY (United States)

    1967-07-15

    For comparison of the effectiveness of non-uniform versus uniform irradiations in causing haematological death in mammals, a model of the irradiated haemopoietic system has been proposed. The essential features of this model are: (1) that different parts of the haemopoietic system have numbers of stem cells which are proportioned to the amounts of active marrow in those parts as measured by {sup 59}Fe uptake, (2) that stem cells in the different parts are subject to the, same dose-survival relationship, and (3) that survival of the animal depends on survival of a critical fraction of the total number of stem cells independent of their distribution among the parts of the total marrow mass. To apply this model one needs to know: (a) the relative {sup 59}Fe uptakes of the different parts of the haemopoietic system, (b) the doses delivered to those parts by each of the exposures to be compared, and (c) the dose-survival curve applicable to the stem cells. From these one can calculate the fraction of stem cells surviving each exposure. In a preliminary communication the applicability of the model was investigated using data obtained entirely from the literature. Additional data, particularly on bone-marrow distribution, have since been obtained and are included here. The primary object of the present paper is to test further the validity of the above 'stem-cell survival model'. Data on bilateral (essentially uniform) versus unilateral and non-uniform rotational exposures in mammals are examined with respect to the surviving fraction of stem cells at the LD{sub 50/30} day dose level. Although an adequate test is not possible at present for lack of a full set of data in any one species, a partial test indicates compatibility with data for dogs and rats. Other possible mortality determinants such as doses or exposures at entrance, midline or exit, or the gram-rads or average dose to the marrow, appear to be less useful than the critical stem-cell survival fraction.

  20. Uniform magnetic fields in density-functional theory

    Science.gov (United States)

    Tellgren, Erik I.; Laestadius, Andre; Helgaker, Trygve; Kvaal, Simen; Teale, Andrew M.

    2018-01-01

    We construct a density-functional formalism adapted to uniform external magnetic fields that is intermediate between conventional density functional theory and Current-Density Functional Theory (CDFT). In the intermediate theory, which we term linear vector potential-DFT (LDFT), the basic variables are the density, the canonical momentum, and the paramagnetic contribution to the magnetic moment. Both a constrained-search formulation and a convex formulation in terms of Legendre-Fenchel transformations are constructed. Many theoretical issues in CDFT find simplified analogs in LDFT. We prove results concerning N-representability, Hohenberg-Kohn-like mappings, existence of minimizers in the constrained-search expression, and a restricted analog to gauge invariance. The issue of additivity of the energy over non-interacting subsystems, which is qualitatively different in LDFT and CDFT, is also discussed.

  1. Test stand for non-uniformity correction of microbolometer focal plane arrays used in thermal cameras

    Science.gov (United States)

    Krupiński, Michał; Bareła, Jaroslaw; Firmanty, Krzysztof; Kastek, Mariusz

    2013-10-01

    Uneven response of particular detectors (pixels) to the same incident power of infrared radiation is an inherent feature of microbolometer focal plane arrays. As a result an image degradation occurs, known as Fixed Pattern Noise (FPN), which distorts the thermal representation of an observed scene and impairs the parameters of a thermal camera. In order to compensate such non-uniformity, several NUC correction methods are applied in digital data processing modules implemented in thermal cameras. Coefficients required to perform the non-uniformity correction procedure (NUC coefficients) are determined by calibrating the camera against uniform radiation sources (blackbodies). Non-uniformity correction is performed in a digital processing unit in order to remove FPN pattern in the registered thermal images. Relevant correction coefficients are calculated on the basis of recorded detector responses to several values of radiant flux emitted from reference IR radiation sources (blackbodies). The measurement of correction coefficients requires specialized setup, in which uniform, extended radiation sources with high temperature stability are one of key elements. Measurement stand for NUC correction developed in Institute of Optoelectronics, MUT, comprises two integrated extended blackbodies with the following specifications: area 200×200 mm, stabilized absolute temperature range +15 °C÷100 °C, and uniformity of temperature distribution across entire surface +/-0.014 °C. Test stand, method used for the measurement of NUC coefficients and the results obtained during the measurements conducted on a prototype thermal camera will be presented in the paper.

  2. Optimal Value of Series Capacitors for Uniform Field Distribution in Transmission Line MRI Coils

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy

    2016-01-01

    Transmission lines are often used as coils in high field magnetic resonance imaging (MRI). Due to the distributed nature of transmission lines, coils based on them produce inhomogeneous field. This work investigates application of series capacitors to improve field homogeneity along the coil....... The equations for optimal values of evenly distributed capacitors are derived and expressed in terms of the implemented transmission line parameters.The achieved magnetic field homogeneity is estimated under quasistatic approximation and compared to the regular transmission line resonator. Finally, a more...... practical case of a microstrip line coil with two series capacitors is considered....

  3. Illumination non-uniformity of spirally wobbling beam in heavy ion fusion

    International Nuclear Information System (INIS)

    Suzuki, T.; Noguchi, K.; Kurosaki, T.; Barada, D.; Kawata, S.; Ma, Y. Y.; Ogoyski, A.I.

    2016-01-01

    In inertial confinement fusion, the driver beam illumination non-uniformity leads a degradation of fusion energy output. The illumination non-uniformity allowed is less than a few percent in inertial fusion target implosion. Heavy ion beam (HIB) accelerator provides a capability to oscillate a beam axis with a high frequency. The wobbling beams may provide a new method to reduce or smooth the beam illumination non-uniformity. In this paper the HIBs wobbling illumination scheme was optimized. (paper)

  4. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    also the high dose volume. The optimization on dose points and geometry provides the most uniform dose distribution. The dose non-uniformity ratio can be minimized by selecting the isodose line of the midpoints between the catheters in the whole volume for the dose prescription, but the dose coverage may not be adequate. For a clinically acceptable plan, a compromise should be made between dose non-uniformity and coverage. (author)

  5. Comparative study of random and uniform models for the distribution of TRISO particles in HTR-10 fuel elements

    International Nuclear Information System (INIS)

    Rosales, J.; Perez, J.; Garcia, C.; Munnoz, A.; Lira, C. A. B. O.

    2015-01-01

    TRISO particles are the specific features of HTR-10 and generally HTGR reactors. Their heterogeneity and random arrangement in graphite matrix of these reactors create a significant modeling challenge. In the simulation of spherical fuel elements using MCNPX are usually created repetitive structures using uniform distribution models. The use of these repetitive structures introduces two major approaches: the non-randomness of the TRISO particles inside the pebbles and the intersection of the pebble surface with the TRISO particles. These approaches could affect significantly the multiplicative properties of the core. In order to study the influence of these approaches in the multiplicative properties was estimated the K inf value in one pebble with white boundary conditions using 4 different configurations regarding the distribution of the TRISO particles inside the pebble: uniform hexagonal model, cubic uniform model, cubic uniform without the effect of cutting and a random distribution model. It was studied the impact these models on core scale solving the problem B1, from the Benchmark Problems presented in a Coordinated Research Program of the IAEA. (Author)

  6. Generation of uniform magnetic field using a spheroidal helical coil structure

    International Nuclear Information System (INIS)

    Öztürk, Yavuz; Aktaş, Bekir

    2016-01-01

    Uniformity of magnetic fields are of great importance especially in magnetic resonance studies, namely in magnetic resonance spectroscopy applications (NMR, FMR, ESR, EPR etc.) and magnetic resonance imaging applications (MRI, FMRI). Field uniformity is also required in some other applications such as eddy current probes, magnetometers, magnetic traps, particle counters etc. Here we proposed a coil winding regime, which follows the surface of a spheroid (an ellipsoid of rotation); in light of previous theoretical studies suggesting perfect uniformity for a constant ampere per turn in the axial direction thereof. We demonstrated our theoretical results from finite element calculations suggesting 0.15% of field uniformity for the proposed structure, which we called a Spheroidal Helical Coil. (paper)

  7. Calculation of the fuel temperature coefficient of reactivity considering non-uniform radial temperature distribution in the fuel rod

    Energy Technology Data Exchange (ETDEWEB)

    Pazirandeh, Ali [Islamic Azad Univ., Tehran (Iran, Islamic Republic of). Science and Research Branch; Hooshyar Mobaraki, Almas

    2017-07-15

    The safe operation of a reactor is based on feedback models. In this paper we attempted to discuss the influence of a non-uniform radial temperature distribution on the fuel rod temperature coefficient of reactivity. The paper demonstrates that the neutron properties of a reactor core is based on effective temperature of the fuel to obtain the correct fuel temperature feedback. The value of volume-averaged temperature being used in the calculations of neutron physics with feedbacks would result in underestimating the probable event. In the calculation it is necessary to use the effective temperature of the fuel in order to provide correct accounting of the fuel temperature feedback. Fuel temperature changes in different zones of the core and consequently reactivity coefficient change are an important parameter for analysis of transient conditions. The restricting factor that compensates the inserted reactivity is the temperature reactivity coefficient and effective delayed neutron fraction.

  8. Dynamically assisted Schwinger effect beyond the spatially-uniform-field approximation

    Science.gov (United States)

    Aleksandrov, I. A.; Plunien, G.; Shabaev, V. M.

    2018-06-01

    We investigate the phenomenon of electron-positron pair production from vacuum in the presence of a strong electric field superimposed by a weak but fast varying pulse which substantially increases the total particle yield. We employ a nonperturbative numerical technique and perform the calculations beyond the spatially-uniform-field approximation, i.e., dipole approximation, taking into account the coordinate dependence of the fast component. The analysis of the main characteristics of the pair-production process (momentum spectra of particles and total amount of pairs) reveals a number of important features which are absent within the previously used approximation. In particular, the structure of the momentum distribution is modified both qualitatively and quantitatively, and the total number of pairs created as well as the enhancement factor due to dynamical assistance become significantly smaller.

  9. Simulation of therapeutic electron beam tracking through a non-uniform magnetic field using finite element method.

    Science.gov (United States)

    Tahmasebibirgani, Mohammad Javad; Maskani, Reza; Behrooz, Mohammad Ali; Zabihzadeh, Mansour; Shahbazian, Hojatollah; Fatahiasl, Jafar; Chegeni, Nahid

    2017-04-01

    In radiotherapy, megaelectron volt (MeV) electrons are employed for treatment of superficial cancers. Magnetic fields can be used for deflection and deformation of the electron flow. A magnetic field is composed of non-uniform permanent magnets. The primary electrons are not mono-energetic and completely parallel. Calculation of electron beam deflection requires using complex mathematical methods. In this study, a device was made to apply a magnetic field to an electron beam and the path of electrons was simulated in the magnetic field using finite element method. A mini-applicator equipped with two neodymium permanent magnets was designed that enables tuning the distance between magnets. This device was placed in a standard applicator of Varian 2100 CD linear accelerator. The mini-applicator was simulated in CST Studio finite element software. Deflection angle and displacement of the electron beam was calculated after passing through the magnetic field. By determining a 2 to 5cm distance between two poles, various intensities of transverse magnetic field was created. The accelerator head was turned so that the deflected electrons became vertical to the water surface. To measure the displacement of the electron beam, EBT2 GafChromic films were employed. After being exposed, the films were scanned using HP G3010 reflection scanner and their optical density was extracted using programming in MATLAB environment. Displacement of the electron beam was compared with results of simulation after applying the magnetic field. Simulation results of the magnetic field showed good agreement with measured values. Maximum deflection angle for a 12 MeV beam was 32.9° and minimum deflection for 15 MeV was 12.1°. Measurement with the film showed precision of simulation in predicting the amount of displacement in the electron beam. A magnetic mini-applicator was made and simulated using finite element method. Deflection angle and displacement of electron beam were calculated. With

  10. The zero-point field in non-inertial frames

    International Nuclear Information System (INIS)

    Hacyan, S.

    1985-01-01

    The energy spectrum of the zero-point field as seen in non-inertial frames is investigated. Uniformly accelerated frames and black holes are considered. It is suggested that the radiation produced by black holes or acceleration is a manifestation of the zero-point field and of the same nature (whether real or virtual)

  11. Improvement of dose distribution of esophageal irradiation using the field-within-a-field technique

    International Nuclear Information System (INIS)

    Iwai, Tsugunori; Okabe, Keigo; Yamato, Hidetada; Murakami, Jyunji; Nakazawa, Yasuo; Kato, Mitsuyoshi

    2002-01-01

    The wide radiation field for mediastinal dose distribution should be inhomogeneous with the usual simple opposed beam irradiation. The purpose of this study was to improve the dose distribution of the mediastinum using a conventional planning system with a dose-volume histogram (DVH) and the field-in-field technique. Three-dimensional (3D) dose distribution is obtained in bilateral opposed-field irradiation. An overdose area obtained from the 3D dose distribution is defined and reprojected into the irradiation field. A new reduced field is created by removing the reprojected overdose area. A 3D dose distribution is again obtained and compared with the results from first one. Procedures were repeated until each of the target volumes was within ±5% of the prescribed dose and the irradiation volume within 107% or less of the prescribed dose. From the DVH analysis, our field-within-a-field technique resulted in a more uniform dose distribution within the conventional planning. The field-within-a-field technique involves many parameters, and an inverse planning algorithm is suitable for computation. However, with our method, the forward planning system is adequate for planning, at least in a relatively straightforward planning system such as bilateral opposed fields therapy. (author)

  12. Proposal for a Domain Wall Nano-Oscillator driven by Non-uniform Spin Currents

    Science.gov (United States)

    Sharma, Sanchar; Muralidharan, Bhaskaran; Tulapurkar, Ashwin

    2015-09-01

    We propose a new mechanism and a related device concept for a robust, magnetic field tunable radio-frequency (rf) oscillator using the self oscillation of a magnetic domain wall subject to a uniform static magnetic field and a spatially non-uniform vertical dc spin current. The self oscillation of the domain wall is created as it translates periodically between two unstable positions, one being in the region where both the dc spin current and the magnetic field are present, and the other, being where only the magnetic field is present. The vertical dc spin current pushes it away from one unstable position while the magnetic field pushes it away from the other. We show that such oscillations are stable under noise and can exhibit a quality factor of over 1000. A domain wall under dynamic translation, not only being a source for rich physics, is also a promising candidate for advancements in nanoelectronics with the actively researched racetrack memory architecture, digital and analog switching paradigms as candidate examples. Devising a stable rf oscillator using a domain wall is hence another step towards the realization of an all domain wall logic scheme.

  13. A new correlation of non-uniformly heated round tube burnout data

    International Nuclear Information System (INIS)

    Kirby, G.J.

    1966-07-01

    A new correlation of non-uniformly heated round tube burnout data is presented. This fits the available data better than any previously published correlation - the root-mean-square deviation being 5.7% for all data at 1000 p.s.i.a. and the worst fit being to data at 2000 p.s.i.a. where the r.m.s. error is 6.6%. The correlation is used to investigate the effect of flux profile changes and no significant increase in burnout power is obtained by modifying the present chopped cosine distribution. (author)

  14. Thermal stability improvement of a multiple finger power SiGe heterojunction bipolar transistor under different power dissipations using non-uniform finger spacing

    International Nuclear Information System (INIS)

    Chen Liang; Zhang Wan-Rong; Jin Dong-Yue; Shen Pei; Xie Hong-Yun; Ding Chun-Bao; Xiao Ying; Sun Bo-Tao; Wang Ren-Qing

    2011-01-01

    A method of non-uniform finger spacing is proposed to enhance thermal stability of a multiple finger power SiGe heterojunction bipolar transistor under different power dissipations. Temperature distribution on the emitter fingers of a multi-finger SiGe heterojunction bipolar transistor is studied using a numerical electro-thermal model. The results show that the SiGe heterojunction bipolar transistor with non-uniform finger spacing has a small temperature difference between fingers compared with a traditional uniform finger spacing heterojunction bipolar transistor at the same power dissipation. What is most important is that the ability to improve temperature non-uniformity is not weakened as power dissipation increases. So the method of non-uniform finger spacing is very effective in enhancing the thermal stability and the power handing capability of power device. Experimental results verify our conclusions. (interdisciplinary physics and related areas of science and technology)

  15. Influences of non-uniform pressure field outside bubbles on the propagation of acoustic waves in dilute bubbly liquids.

    Science.gov (United States)

    Zhang, Yuning; Du, Xiaoze

    2015-09-01

    Predictions of the propagation of the acoustic waves in bubbly liquids is of great importance for bubble dynamics and related applications (e.g. sonochemistry, sonochemical reactor design, biomedical engineering). In the present paper, an approach for modeling the propagation of the acoustic waves in dilute bubbly liquids is proposed through considering the non-uniform pressure field outside the bubbles. This approach is validated through comparing with available experimental data in the literature. Comparing with the previous models, our approach mainly improves the predictions of the attenuation of acoustic waves in the regions with large kR0 (k is the wave number and R0 is the equilibrium bubble radius). Stability of the oscillating bubbles under acoustic excitation are also quantitatively discussed based on the analytical solution. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Curved-straight neutron guide system with uniform spatial intensity distribution

    International Nuclear Information System (INIS)

    Mildner, D.F.R.; Cook, J.C.

    2008-01-01

    The spatial intensity distribution of neutrons emerging from a curved guide is asymmetric, and straight guide sections are sometimes appended to curved guides to make the intensity distribution more nearly uniform. For idealized uniform illumination and in the perfect reflectivity approximation, the spatial-angular acceptance at the exit of the combination can be made exactly uniform for a range of long wavelengths by using a sufficiently long straight section, together with a curved guide whose outer wall coating has a critical angle slightly greater than those of the other guide walls. We refer to this as a 'phase space tailoring guide' where the coatings on the inner wall and straight section are used to define the required divergence at the end of the guide. Increasing the critical angle of the outer wall of the curved section reduces the characteristic wavelength of the curved guide as well as the wavelength at which ideal uniformity can be obtained. The outer wall coating need only be of sufficiently high critical angle to fill the transmittable phase space area of the straight guide uniformly to adequately short wavelength

  17. Breakdown characteristics of SF6/N2 in severely non-uniform electric fields at low temperatures

    Science.gov (United States)

    Wang, Y.; Gao, Z. W.; Li, G. X.; Zhu, X. C.; Yu, C. L.; Liang, J. Q.; Li, L.

    2018-01-01

    SF6 has good electrical insulating properties, which is widely used as an insulating medium of GIS, GIL and other electrical equipment. However, the reliability of electrical equipments´ insulated gas is greatly challenged in cold areas, since SF6 more readily liquefies. To solve the problem, SF6 can be mixed with N2 to maintain the insulating properties, and reduce its liquefaction temperature. Such practice has certain application prospect. In this paper, a breakdown experimental platform was built to study the insulating property of SF6/N2 at low temperature, wherein the temperature of the platform can be adjusted. A severely non-uniform electric field was generated by a rod-plate electrode. The breakdown characteristics of SF6/N2 with different mixing proportions at low pressures and low temperatures were measured. The result showed that the mixed gas was not liquefied within the temperature range. Temperature had insignificant influence on the insulating property thereof. The result in the paper has certain guiding significance for applying SF6/N2 mixed gas in high latitude areas.

  18. Study of the distribution of maxima and minima in multiple sequential images of uniformity

    International Nuclear Information System (INIS)

    Llacer Martos, S.; Puchal Ane, R.

    2011-01-01

    To characterize the uniformity of a gamma camera extrinsic used integral uniformity coefficient is calculated with the value of two pixels, the maximum and minimum, single source acquisition of a flat and uniform. This method does not take into account the fact that if a gamma camera having a uniform response, the distribution of these items should be random. In this paper we study how these points are distributed in a succession of large numbers of uniform images.

  19. Improvement of the growth and yield of lettuce plants by elf sinusoidal non-uniform magnetic fields

    International Nuclear Information System (INIS)

    Souzal, A. De; Gonzalez, L.M.; Sueirol, L.; Peralta, O.; Liceal, L.; Porras, E.; Gilart, F.

    2008-01-01

    Influence of pre-sowing magnetic treatments on plant growth and final yield of lettuce (cv. Black Seeded Simpson) were studied under organoponic conditions. Lettuce seeds were exposed to full-wave rectified sinusoidal non-uniform magnetic fields (MFs) induced by an electromagnet at 120 mT(rms) for 3 min, 160 mT(rms) for 1 min and to 160 mT (rms) for 5 min. Non-treated seeds were considered as controls. Plants were grown in experimental stonemasons (25.2 m2) of an organoponic and cultivated according to standard agricultural practices. During nursery and vegetative growth stages, samples were collected at regular intervals for seedling growth assessment and growth rate analyses. At physiological maturity, the plants were harvested from each stonemason and the final yield and yield parameters were determined. In the nursery stage, the magnetic treatments induced a significant increase of root length and shoot height in plants derived from magnetically-treated seeds. In the vegetative stage, the relative growth rates of plants derived from magnetically-exposed seeds were greater than those shown by the control plants. At maturity stage, all magnetic treatments increased significantly (p<0.05) the plant height, the leaf area per plant, the final yield per area and the fresh mass per plant in comparison with the controls. Pre-sowing magnetic treatments would enhance the growth and final yield of lettuce crop

  20. Effect of non-uniform current distribution on the stability in Nb-Ti cable-in-conduit superconducting conductor

    International Nuclear Information System (INIS)

    Wadayama, Y.; Koizumi, N.; Takahashi, Y.; Matsui, K.; Tsuji, H.; Shimamoto, S.

    1996-01-01

    30kA-NbTi Demo Poloidal Coil (DPC-U) exhibited instability such as the conductor quenches at 40% of the rated current which is still much smaller than the expected conductor critical current. It was found that this instability was caused by the non-uniform current distribution in the DPC-U conductor whose strands were insulated from each other. To investigate the instability of the DPC-U conductor, a stability experiment of a subsize conductor consisting of 27 strands was performed and the effect of the current imbalance on the stability was investigated. The current imbalance was forcibly established in the conductor using two current sources in this experiment. The experimental results indicate that the stability margin decreases as the current imbalance becomes larger and that the stability margin of the conductor is governed by the stability of the strand with the highest current in the conductor. Also, it is confirmed from the experimental results that the instability of DPC-U has to be attributed to the current imbalance in the conductor

  1. Parallel processing and non-uniform grids in global air quality modeling

    NARCIS (Netherlands)

    Berkvens, P.J.F.; Bochev, Mikhail A.

    2002-01-01

    A large-scale global air quality model, running efficiently on a single vector processor, is enhanced to make more realistic and more long-term simulations feasible. Two strategies are combined: non-uniform grids and parallel processing. The communication through the hierarchy of non-uniform grids

  2. Controlling of density uniformity of polyacrylate foams

    International Nuclear Information System (INIS)

    Shan Wenwen; Yuan Baohe; Wang Yanhong; Xu Jiayun; Zhang Lin

    2010-01-01

    The density non-uniformity existing in most low-density foams will affect performance of the foams. The trimethylolpropane trimethacrylate (TMPTA) foam targets were prepared and controlling methods of the foams, density uniformity were explored together with its forming mechanism. It has been found that the UV-light with high intensity can improve the distribution uniformity of the free radicals induced by UV photons in the solvents, thus improve the density uniformity of the foams. In addition, container wall would influence the concentration distribution of the solution, which affects the density uniformity of the foams. Thus, the UV-light with high intensity was chosen together with polytetrafluoroethylene molds instead of glass molds to prepare the foams with the density non-uniformity less than 10%. β-ray detection technology was used to measure the density uniformity of the TMPTA foams with the density in the range of 10 to 100 mg · cm -3 , and the results show that the lower the foam density is, the worse the density uniformity is. (authors)

  3. The development of criteria for limiting the non-uniform irradiation of skin: the rationale for a study of non-stochastic effects

    International Nuclear Information System (INIS)

    Wells, J.; Charles, M.W.

    1979-06-01

    Recent recommendations of the ICRP (1977) provide little guidance for the treatment of non-uniform skin exposures such as those which may occur as the result of contamination with radioactive particulates. This lack of guidance is due to a paucity of data regarding biological effects in this area. A rationale is presented for the study of the early (non-stochastic) effects of non-uniform skin irradiation. As a basis for the presentation of this rationale a framework is provided by a resume of basic biology of the skin and a review of previous experimental work in this field. Animal experiments, which are being carried out in collaboration with specialist university groups, are described both in terms of broad concept and experimental detail. The aim is to provide biological data which can provide guidance in radiological protection situations. (author)

  4. Non-uniform Mutation Rates for Problems with Unknown Solution Lengths

    DEFF Research Database (Denmark)

    Cathabard, Stephan; Lehre, Per Kristian; Yao, Xin

    2011-01-01

    Many practical optimisation problems allow candidate solu- tions of varying lengths, and where the length of the opti- mal solution is thereby a priori unknown. We suggest that non-uniform mutation rates can be beneficial when solving such problems. In particular, we consider a mutation oper- ator...... that flips each bit with a probability that is inversely proportional to the bit position, rather than the bitstring length. The runtime of the (1+1) EA using this mutation operator is analysed rigorously on standard example func- tions. Furthermore, the behaviour of the new mutation op- erator...... distribution, and show that the new operator can yield exponentially faster runtimes for some parameters of this distribution. The experimental results show that the new mutation operator leads to dramatically shorter runtimes on a class of instances of the software engi- neering problem that is conjectured...

  5. ANALYSIS ON THE DYNAMICS OF SPATIAL DISTRIBUTION PATTERN OF MIXED SPIDER POPULATION IN RICE FIELD

    Institute of Scientific and Technical Information of China (English)

    ZhiWang; Zhe-mingYuan; Da-xiangSong; Ming-shengZhu

    2004-01-01

    The results make it clear that there are total 11 families, 29 genera and 43 species of spiders in the rice field of Dong Fang Hong Farm. Among them, there are 8 families, 19 genera and 28 species in the early rice field, and 10 families, 27 genera and 36 species in the late rice field. The spatial distribution pattern of mixed spider populations in rice fields was different during different development stages of rice plant. During the prophase, metaphase and anaphase of early rice plant development, the spatial distribution pattern of mixed spider populations was aggregative, random and aggregative respectively. During the prophase, metaphase and anaphase of late rice plant development, the spatial distribution pattern was uniform, aggregative and uniform respectively.

  6. Current and field distribution in high temperature superconductors

    International Nuclear Information System (INIS)

    Johnston, M.D.

    1998-01-01

    The manufacture of wires from HTS materials containing copper-oxide planes is difficult because their physical and electrical properties are highly anisotropic. The electrical connectivity depends on the nearest-neighbour grain alignment and although a high degree of grain texture is achieved through processing, the tape microstructure is generally far from uniform, with weak links and porosity also complicating the picture. In order to optimise the processing, the microstructural features common to good tapes must be identified, requiring knowledge of the local properties. The preferential path taken by transport current is determined by the properties of the local microstructure and as such can be used to measure the variation in quality across the tape cross-section. By measuring the self-field profile generated by a current-carrying tape, it is possible to extract the associated current distribution. I have designed and built a Scanning Hall Probe Microscope to measure the normal field distribution above superconductor tapes carrying DC currents, operating at liquid nitrogen temperature and zero applied magnetic field. It has a spatial resolution of 50*50 μm and a field sensitivity of 5 μT, and can scan over a distance of 6 mm. The current extraction is performed by means of a deconvolution procedure based on Legendre functions. This allows a nondestructive, non-invasive method of evaluating the effects of the processing on the tapes - especially when correlated with transport and magnetisation measurement data. Conductors fabricated from Bi 2 Sr 2 Ca 2 Cu 3 O 10 , Bi 2 Sr 2 CaCu 2 O 8 and (Tl 0.78 Bi 0.22 )(Sr 0.8 Ba 0.2 ) 2 Ca 2 Cu 3 O x , have been investigated. I have confirmed the reports that in Bi-2223/Ag mono-core conductors produced by the oxide-powder-in-tube (OPIT) technique, the current flows predominantly at the edges of the tape, where the grains are long and well-aligned. This is in contrast to Bi-2212 ribbons, where the better microstructure

  7. Non-uniform temperature gradients and thermal stresses produced ...

    Indian Academy of Sciences (India)

    thermally-induced stress distributions in a hollow steel sphere heated by a moving uniform ... models to evaluate temperatures according to the frictional heat generation, ... of these thermal effects include thermal stress, strain and deformation.

  8. Investigation of uniformity field generated from freeform lens with UV LED exposure system

    Science.gov (United States)

    Ciou, F. Y.; Chen, Y. C.; Pan, C. T.; Lin, P. H.; Lin, P. H.; Hsu, F. T.

    2015-03-01

    In the exposure process, the intensity and uniformity of light in the exposure area directly influenced the precision of products. UV-LED (Ultraviolet Light-Emitting Diode) exposure system was established to reduce the radiation leakage and increase the energy efficiency for energy saving. It is a trend that conventional mercury lamp could be replaced with UV-LED exposure system. This study was based on the law of conservation of energy and law of refraction of optical field distributing on the target plane. With these, a freeform lens with uniform light field of main exposure area could be designed. The light outside the exposure area could be concentrated into the area to improve the intensity of light. The refraction index and UV transmittance of Polydimethylsiloxane (PDMS) is 1.43 at 385 nm wavelength and 85-90%, respectively. The PDMS was used to fabricate the optics lens for UV-LEDs. The average illumination and the uniformity could be obtained by increasing the number of UV-LEDs and the spacing of different arrangement modes. After exposure process with PDMS lens, about 5% inaccuracy was obtained. Comparing to 10% inaccuracy of general exposure system, it shows that it is available to replace conventional exposure lamp with using UV-LEDs.

  9. On natural frequencies of non-uniform beams modulated by finite periodic cells

    International Nuclear Information System (INIS)

    Xu, Yanlong; Zhou, Xiaoling; Wang, Wei; Wang, Longqi; Peng, Fujun; Li, Bin

    2016-01-01

    It is well known that an infinite periodic beam can support flexural wave band gaps. However, in real applications, the number of the periodic cells is always limited. If a uniform beam is replaced by a non-uniform beam with finite periodicity, the vibration changes are vital by mysterious. This paper employs the transfer matrix method (TMM) to study the natural frequencies of the non-uniform beams with modulation by finite periodic cells. The effects of the amounts, cross section ratios, and arrangement forms of the periodic cells on the natural frequencies are explored. The relationship between the natural frequencies of the non-uniform beams with finite periodicity and the band gap boundaries of the corresponding infinite periodic beam is also investigated. Numerical results and conclusions obtained here are favorable for designing beams with good vibration control ability. - Highlights: • The transfer matrix method to study the natural frequencies of the finite periodic non-uniform beams is derived. • The transfer matrix method to study the band gaps of the infinite periodic non-uniform beams is derived. • The effects of the periodic cells on the natural frequencies are explored. • The relationships of the natural frequencies and band gap boundaries are investigated.

  10. On natural frequencies of non-uniform beams modulated by finite periodic cells

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yanlong, E-mail: xuyanlong@nwpu.edu.cn [School of Aeronautics, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China); Zhou, Xiaoling [Shanghai Institute of Aerospace System Engineering, Shanghai 201109 (China); Wang, Wei [School of Aeronautics, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China); Wang, Longqi [School of Civil & Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Peng, Fujun [Shanghai Institute of Aerospace System Engineering, Shanghai 201109 (China); Li, Bin [School of Aeronautics, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China)

    2016-09-23

    It is well known that an infinite periodic beam can support flexural wave band gaps. However, in real applications, the number of the periodic cells is always limited. If a uniform beam is replaced by a non-uniform beam with finite periodicity, the vibration changes are vital by mysterious. This paper employs the transfer matrix method (TMM) to study the natural frequencies of the non-uniform beams with modulation by finite periodic cells. The effects of the amounts, cross section ratios, and arrangement forms of the periodic cells on the natural frequencies are explored. The relationship between the natural frequencies of the non-uniform beams with finite periodicity and the band gap boundaries of the corresponding infinite periodic beam is also investigated. Numerical results and conclusions obtained here are favorable for designing beams with good vibration control ability. - Highlights: • The transfer matrix method to study the natural frequencies of the finite periodic non-uniform beams is derived. • The transfer matrix method to study the band gaps of the infinite periodic non-uniform beams is derived. • The effects of the periodic cells on the natural frequencies are explored. • The relationships of the natural frequencies and band gap boundaries are investigated.

  11. Strong-field non-sequential ionization: The vector momentum distribution of multiply charged Ne ions

    International Nuclear Information System (INIS)

    Rottke, H.; Trump, C.; Wittmann, M.; Korn, G.; Becker, W.; Hoffmann, K.; Sandner, W.; Moshammer, R.; Feuerstein, B.; Dorn, A.; Schroeter, C.D.; Ullrich, J.; Schmitt, W.

    2000-01-01

    COLTRIMS (COLd Target Recoil-Ion Momentum Spectroscopy) was used to measure the vector momentum distribution of Ne n+ (n=1,2,3) ions formed in ultrashort (30 fsec) high-intensity (≅10 15 W/cm 2 ) laser pulses with center wavelength at 795 nm. To a high degree of accuracy the length of the Ne n+ ion momentum vector is equal to the length of the total momentum vector of the n photoelectrons released, with both vectors pointing into opposite directions. At a light intensity where non-sequential ionization of the atom dominates the Ne 2+ and Ne 3+ momentum distributions show distinct maxima at 4.0 a.u. and 7.5 a.u. along the polarization axis of the linearly polarized light beam. First, this is a clear signature of non-sequential multiple ionization. Second, it indicates that instantaneous emission of two (or more) electrons at electric field strength maxima of the light wave can be ruled out as main mechanism of non-sequential strong-field multiple ionization. In contrast, this experimental result is in accordance with the kinematical constraints of the 'rescattering model'

  12. Optical property of few-mode fiber with non-uniform refractive index for cylindrical vector beam generation

    Science.gov (United States)

    Li, Hongye; Wan, Hongdan; Zhang, Zuxing; Sun, Bing; Zhang, Lin

    2016-10-01

    This paper investigates optical properties of few-mode fiber with non-uniform refractive index, namely: the few mode fiber with U-shape refractive index and the two-mode and four-mode few-mode fiber with bent radius. Finite element method is used to analyze the mode distributions based on their non-uniform refractive index. Effective mode control can be achieved through these few mode fibers to achieve vector beam generation. Finally, reflection spectra of a few-mode fiber Bragg grating are calculated theoretically and then measured under different bending conditions. Experimental results are in good accordance with the theoretical ones. These few mode fibers show potential applications in generation of cylindrical vector beam both for optical lasing and sensing systems.

  13. Problem of uniqueness in the renewal process generated by the uniform distribution

    Directory of Open Access Journals (Sweden)

    D. Ugrin-Šparac

    1992-01-01

    Full Text Available The renewal process generated by the uniform distribution, when interpreted as a transformation of the uniform distribution into a discrete distribution, gives rise to the question of uniqueness of the inverse image. The paper deals with a particular problem from the described domain, that arose in the construction of a complex stochastic test intended to evaluate pseudo-random number generators. The connection of the treated problem with the question of a unique integral representation of Gamma-function is also mentioned.

  14. Calibration of EBT2 film by the PDD method with scanner non-uniformity correction.

    Science.gov (United States)

    Chang, Liyun; Chui, Chen-Shou; Ding, Hueisch-Jy; Hwang, Ing-Ming; Ho, Sheng-Yow

    2012-09-21

    exposed to 60° physical wedge fields and the compositive fields, and their relative dose profiles were compared with those from the water phantom measurement. The fitting uncertainty was less than 0.5% due to the many calibration points, and the overall calibration uncertainty was within 3% for doses above 50 cGy, when the average of four films were used for the calibration. According to our study, the non-uniformity calibration factor was found to be independent of the given dose for the EBT2 film and the relative dose differences between the profiles measured by the film and the Profiler were within 1.5% after applying the non-uniformity correction. For the verification tests, the relative dose differences between the measurements by films and in the water phantom, when the average of three films were used, were generally within 3% for the 60° wedge fields and compositive fields, respectively. In conclusion, our method is convenient, time-saving and cost-effective, since no film cutting is needed and only two films with two exposures are needed.

  15. Calibration of EBT2 film by the PDD method with scanner non-uniformity correction

    International Nuclear Information System (INIS)

    Chang Liyun; Ding, Hueisch-Jy; Chui, Chen-Shou; Hwang, Ing-Ming; Ho, Sheng-Yow

    2012-01-01

    exposed to 60° physical wedge fields and the compositive fields, and their relative dose profiles were compared with those from the water phantom measurement. The fitting uncertainty was less than 0.5% due to the many calibration points, and the overall calibration uncertainty was within 3% for doses above 50 cGy, when the average of four films were used for the calibration. According to our study, the non-uniformity calibration factor was found to be independent of the given dose for the EBT2 film and the relative dose differences between the profiles measured by the film and the Profiler were within 1.5% after applying the non-uniformity correction. For the verification tests, the relative dose differences between the measurements by films and in the water phantom, when the average of three films were used, were generally within 3% for the 60° wedge fields and compositive fields, respectively. In conclusion, our method is convenient, time-saving and cost-effective, since no film cutting is needed and only two films with two exposures are needed. (paper)

  16. Heat transfer in boundary layer stagnation-point flow towards a shrinking sheet with non-uniform heat flux

    International Nuclear Information System (INIS)

    Bhattacharyya Krishnendu

    2013-01-01

    In this paper, the effect of non-uniform heat flux on heat transfer in boundary layer stagnation-point flow over a shrinking sheet is studied. The variable boundary heat fluxes are considered of two types: direct power-law variation with the distance along the sheet and inverse power-law variation with the distance. The governing partial differential equations (PDEs) are transformed into non linear self-similar ordinary differential equations (ODEs) by similarity transformations, and then those are solved using very efficient shooting method. The direct variation and inverse variation of heat flux along the sheet have completely different effects on the temperature distribution. Moreover, the heat transfer characteristics in the presence of non-uniform heat flux for several values of physical parameters are also found to be interesting

  17. An improved non-uniformity correction algorithm and its GPU parallel implementation

    Science.gov (United States)

    Cheng, Kuanhong; Zhou, Huixin; Qin, Hanlin; Zhao, Dong; Qian, Kun; Rong, Shenghui

    2018-05-01

    The performance of SLP-THP based non-uniformity correction algorithm is seriously affected by the result of SLP filter, which always leads to image blurring and ghosting artifacts. To address this problem, an improved SLP-THP based non-uniformity correction method with curvature constraint was proposed. Here we put forward a new way to estimate spatial low frequency component. First, the details and contours of input image were obtained respectively by minimizing local Gaussian curvature and mean curvature of image surface. Then, the guided filter was utilized to combine these two parts together to get the estimate of spatial low frequency component. Finally, we brought this SLP component into SLP-THP method to achieve non-uniformity correction. The performance of proposed algorithm was verified by several real and simulated infrared image sequences. The experimental results indicated that the proposed algorithm can reduce the non-uniformity without detail losing. After that, a GPU based parallel implementation that runs 150 times faster than CPU was presented, which showed the proposed algorithm has great potential for real time application.

  18. Processing and properties of pressable ceramic with non-uniform reinforcement for selective-toughening

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Wei [School of Mechanical and Chemical Engineering, The University of Western Australia, Perth, WA 6009 (Australia); School of Dentistry, The University of Western Australia, WA 6009 (Australia); Key Laboratory for Anisotropy and Texture of Materials (Ministry of Education), Northeastern University, Shenyang 110004 (China); Hu, Xiaozhi, E-mail: xiao.zhi.hu@uwa.edu.au [School of Mechanical and Chemical Engineering, The University of Western Australia, Perth, WA 6009 (Australia); Ichim, Paul [School of Dentistry, The University of Western Australia, WA 6009 (Australia); Sun, Xudong [Key Laboratory for Anisotropy and Texture of Materials (Ministry of Education), Northeastern University, Shenyang 110004 (China)

    2012-12-15

    Brittle low-strength and low-toughness pressable dental ceramic can be reinforced by ductile elongated gold-particles (GP). A customized crown structure can be adequately strengthened by distributing GP only in critical sections of the crown, where high tensile stresses are experienced. In the present study, a non-uniformly structured ceramic-matrix composite with excellent interfacial bonding, twofold fracture toughness and strength at desired locations, is fabricated using pressable dental ceramic and GP. The layout pattern and sequence of different GP/ceramic powder mixtures, high-temperature flow properties of these mixtures during hot-pressing and the sample mold geometry are used to control the distribution and locations of GP for selective toughening and strengthening. Nano-crystalline structures of the pressable ceramic-matrix and the nano-scaled interfacial region around GP have been revealed by high-magnification field-emission scanning electron microscopy. Toughening and strengthening mechanisms of the elongated GP including residual stresses from composite processing and ductile fracture of GP are discussed together with SEM observations. Bulk flexural strength and local micro-indentation fracture and deformation characteristics of the selective-toughened ceramic/metal composite have been compared to those of the monolithic pressable ceramic to validate the toughening and strengthening mechanisms.

  19. Processing and properties of pressable ceramic with non-uniform reinforcement for selective-toughening

    International Nuclear Information System (INIS)

    Yi, Wei; Hu, Xiaozhi; Ichim, Paul; Sun, Xudong

    2012-01-01

    Brittle low-strength and low-toughness pressable dental ceramic can be reinforced by ductile elongated gold-particles (GP). A customized crown structure can be adequately strengthened by distributing GP only in critical sections of the crown, where high tensile stresses are experienced. In the present study, a non-uniformly structured ceramic–matrix composite with excellent interfacial bonding, twofold fracture toughness and strength at desired locations, is fabricated using pressable dental ceramic and GP. The layout pattern and sequence of different GP/ceramic powder mixtures, high-temperature flow properties of these mixtures during hot-pressing and the sample mold geometry are used to control the distribution and locations of GP for selective toughening and strengthening. Nano-crystalline structures of the pressable ceramic–matrix and the nano-scaled interfacial region around GP have been revealed by high-magnification field-emission scanning electron microscopy. Toughening and strengthening mechanisms of the elongated GP including residual stresses from composite processing and ductile fracture of GP are discussed together with SEM observations. Bulk flexural strength and local micro-indentation fracture and deformation characteristics of the selective-toughened ceramic/metal composite have been compared to those of the monolithic pressable ceramic to validate the toughening and strengthening mechanisms.

  20. Ultrasonic transducer design for uniform insonation

    International Nuclear Information System (INIS)

    Harrison, G.H.; Balcer-Kubiczek, E.K.; McCulloch, D.

    1984-01-01

    Techniques used in transducer development for acoustical imaging have been evaluated for the purpose of producing broad, uniform ultrasonic fields from planar radiators. Such fields should be useful in hyperthermia, physical therapy, and ultrasonic bioeffects studies. Fourier inversion of the circ function yielded a source velocity distribution proportional to (P/r) exp ((-ik/2Z) (2Z/sup 2/+r/sup 2/)) J/sub 1/(krP/Z), where r is the radial source coordinate, k is the wave number, and P is the desired radius of uniform insonation at a depth Z in water. This source distribution can be truncated without significantly degrading the solution. A simpler solution consists of exponentially shading the edge of an otherwise uniformly excited disk transducer. This approach was successfully approximated experimentally

  1. Non-uniform versus uniform attenuation correction in brain perfusion SPET of healthy volunteers

    International Nuclear Information System (INIS)

    Van Laere, K.; Versijpt, J.; Dierckx, R.; Koole, M.

    2001-01-01

    Although non-uniform attenuation correction (NUAC) can supply more accurate absolute quantification, it is not entirely clear whether NUAC provides clear-cut benefits in the routine clinical practice of brain SPET imaging. The aim of this study was to compare the effect of NUAC versus uniform attenuation correction (UAC) on volume of interest (VOI)-based semi-quantification of a large age- and gender-stratified brain perfusion normal database. Eighty-nine healthy volunteers (46 females and 43 males, aged 20-81 years) underwent standardised high-resolution single-photon emission tomography (SPET) with 925 MBq 99m Tc-ethyl cysteinate dimer (ECD) on a Toshiba GCA-9300A camera with 153 Gd or 99m Tc transmission CT scanning. Emission images were reconstructed by filtered back-projection and scatter corrected using the triple-energy window correction method. Both non-uniform Chang attenuation correction (one iteration) and uniform Sorenson correction (attenuation coefficient 0.09 cm -1 ) were applied. Images were automatically re-oriented to a stereotactic template on which 35 predefined VOIs were defined for semi-quantification (normalisation on total VOI counts). Small but significant differences between relative VOI uptake values for NUAC versus UAC in the infratentorial region were found. VOI standard deviations were significantly smaller for UAC, 4.5% (range 2.6-7.5), than for NUAC, 5.0% (2.3-9.0) (P 99m Tc-ECD uptake values in healthy volunteers to those obtained with NUAC, although values for the infratentorial region are slightly lower. NUAC produces a slight increase in inter-subject variability. Further study is necessary in various patient populations to establish the full clinical impact of NUAC in brain perfusion SPET. (orig.)

  2. The use of non-uniform drowning terminology: a follow-up study.

    Science.gov (United States)

    Schmidt, Andrew C; Sempsrott, Justin R; Szpilman, David; Queiroga, Ana Catarina; Davison, Matt S; Zeigler, Ryan J; McAlister, Sean J

    2017-07-17

    In 2002, the World Congress on Drowning developed a uniform definition for drowning. The aim of this study is to determine the prevalence of "non-uniform drowning terminology" (NUDT) and "non-uniform drowning definitions" (NUDD) in peer-reviewed scientific literature from 2010 to 2016, and compare these findings with those from our unpublished study performing a similar analysis on literature from 2003 to 2010. A systematic review was performed using drowning-specific search terms in Pubmed and Web of Science. Titles and abstracts published between July 2010 and January 2016 were screened for relevance to the study focus. Articles meeting screening criteria were reviewed for exclusion criteria to produce the final group of studies. These articles were reviewed by four reviewers for NUDT and NUDD. The Fisher exact test was used to determine any statistically significant changes. The final group of studies included 167 articles. A total of 53 articles (32%) utilized NUDT, with 100% of these including the term "near drowning". The proportion of articles utilizing NUDT was significantly less than reported by our previous study (p drowning (uniform or non-uniform), with 15% of these utilizing NUDD. Our study reveals a statistically significant improvement over the past thirteen years in the use of uniform drowning terminology in peer-reviewed scientific literature, although year-to-year variability over the current study period does not yield an obvious trend. Of the articles reviewed during the 2010-2016 study period, 32% included outdated and non-uniform drowning terminology and definitions. While this reveals an absolute decrease of 11% as compared with the previous study period (2003-2010), there is still significant room for improvement.

  3. Droplet rotation model apply in steam uniform flow and gravitational field

    International Nuclear Information System (INIS)

    Zhang Jinyi; Bo Hanliang; Sun Yuliang; Wang Dazhong

    2012-01-01

    The mechanism droplet movement behavior and the qualitative description of droplet trajectory in the steam uniform flow field in the gravitational field were researched with droplet rotation model. According to the mechanism of gravitational field and uniform flow fields, the effects on droplets movement were analyzed and the importance of lift forces was also discussed. Finally, a general trajectory and mechanism of the droplets movement was derived which lays the groundwork for the qualitative analysis of the single-drop model and could be general enough to be used in many applications. (authors)

  4. Phase diagram and tricritical behavior of an metamagnet in uniform and random fields

    International Nuclear Information System (INIS)

    Liang Yaqiu; Wei Guozhu; Xu Xiaojuan; Song Guoli

    2010-01-01

    A two-sublattice Ising metamagnet in both uniform and random fields is studied within the mean-field approach based on Bogoliubov's inequality for the Gibbs free energy. We show that the qualitative features of the phase diagrams are dependent on the parameters of the model and the uniform field values. The tricritical point and reentrant phenomenon can be observed on the phase diagram. The reentrance is due to the competition between uniform and random interactions.

  5. Instruction sequences and non-uniform complexity theory

    NARCIS (Netherlands)

    Bergstra, J.A.; Middelburg, C.A.

    2008-01-01

    We develop theory concerning non-uniform complexity in a setting in which the notion of single-pass instruction sequence considered in program algebra is the central notion. We define counterparts of the complexity classes P/poly and NP/poly and formulate a counterpart of the complexity theoretic

  6. Modelling refrigerant distribution in minichannel evaporators

    DEFF Research Database (Denmark)

    Brix, Wiebke

    of the liquid and vapour in the inlet manifold. Combining non-uniform airflow and non-uniform liquid and vapour distribution shows that a non-uniform airflow distribution to some degree can be compensated by a suitable liquid and vapour distribution. Controlling the superheat out of the individual channels...... to be equal, results in a cooling capacity very close to the optimum. A sensitivity study considering parameter changes shows that the course of the pressure gradient in the channel is significant, considering the magnitude of the capacity reductions due to non-uniform liquid and vapour distribution and non......This thesis is concerned with numerical modelling of flow distribution in a minichannel evaporator for air-conditioning. The study investigates the impact of non-uniform airflow and non-uniform distribution of the liquid and vapour phases in the inlet manifold on the refrigerant mass flow...

  7. Free vibration analysis of a robotic fish based on a continuous and non-uniform flexible backbone with distributed masses

    Science.gov (United States)

    Coral, W.; Rossi, C.; Curet, O. M.

    2015-12-01

    This paper presents a Differential Quadrature Element Method for free transverse vibration of a robotic fish based on a continuous and non-uniform flexible backbone with distributed masses (fish ribs). The proposed method is based on the theory of a Timoshenko cantilever beam. The effects of the masses (number, magnitude and position) on the value of natural frequencies are investigated. Governing equations, compatibility and boundary conditions are formulated according to the Differential Quadrature rules. The convergence, efficiency and accuracy are compared to other analytical solution proposed in the literature. Moreover, the proposed method has been validate against the physical prototype of a flexible fish backbone. The main advantages of this method, compared to the exact solutions available in the literature are twofold: first, smaller computational cost and second, it allows analysing the free vibration in beams whose section is an arbitrary function, which is normally difficult or even impossible with other analytical methods.

  8. D2+ Molecular complex in non-uniform height quantum ribbon under crossed electric and magnetic fields

    Science.gov (United States)

    Suaza, Y. A.; Laroze, D.; Fulla, M. R.; Marín, J. H.

    2018-05-01

    The D2+ molecular complex fundamental properties in a uniform and multi-hilled semiconductor quantum ribbon under orthogonal electric and magnetic fields are theoretically studied. The energy structure is calculated by using adiabatic approximation combined with diagonalization procedure. The D2+ energy structure is more strongly controlled by the geometrical structural hills than the Coulomb interaction. The formation of vibrational and rotational states is discussed. Aharanov-Bohm oscillation patterns linked to rotational states as well as the D2+ molecular complex stability are highly sensitive to the number of hills while electric field breaks the electron rotational symmetry and removes the energy degeneration between low-lying states.

  9. Random noise attenuation of non-uniformly sampled 3D seismic data along two spatial coordinates using non-equispaced curvelet transform

    Science.gov (United States)

    Zhang, Hua; Yang, Hui; Li, Hongxing; Huang, Guangnan; Ding, Zheyi

    2018-04-01

    The attenuation of random noise is important for improving the signal to noise ratio (SNR). However, the precondition for most conventional denoising methods is that the noisy data must be sampled on a uniform grid, making the conventional methods unsuitable for non-uniformly sampled data. In this paper, a denoising method capable of regularizing the noisy data from a non-uniform grid to a specified uniform grid is proposed. Firstly, the denoising method is performed for every time slice extracted from the 3D noisy data along the source and receiver directions, then the 2D non-equispaced fast Fourier transform (NFFT) is introduced in the conventional fast discrete curvelet transform (FDCT). The non-equispaced fast discrete curvelet transform (NFDCT) can be achieved based on the regularized inversion of an operator that links the uniformly sampled curvelet coefficients to the non-uniformly sampled noisy data. The uniform curvelet coefficients can be calculated by using the inversion algorithm of the spectral projected-gradient for ℓ1-norm problems. Then local threshold factors are chosen for the uniform curvelet coefficients for each decomposition scale, and effective curvelet coefficients are obtained respectively for each scale. Finally, the conventional inverse FDCT is applied to the effective curvelet coefficients. This completes the proposed 3D denoising method using the non-equispaced curvelet transform in the source-receiver domain. The examples for synthetic data and real data reveal the effectiveness of the proposed approach in applications to noise attenuation for non-uniformly sampled data compared with the conventional FDCT method and wavelet transformation.

  10. Impact of roof height non-uniformity on pollutant transport between a street canyon and intersections

    International Nuclear Information System (INIS)

    Nosek, Štěpán; Kukačka, Libor; Jurčáková, Klára; Kellnerová, Radka; Jaňour, Zbyněk

    2017-01-01

    This paper presents an extension of our previous wind-tunnel study (Nosek et al., 2016) in which we highlighted the need for investigation of the removal mechanisms of traffic pollution from all openings of a 3D street canyon. The extension represents the pollution flux (turbulent and advective) measurements at the lateral openings of three different 3D street canyons for the winds perpendicular and oblique to the along-canyon axis. The pollution was simulated by emitting a passive gas (ethane) from a homogeneous ground-level line source positioned along the centreline of the investigated street canyons. The street canyons were formed by courtyard-type buildings of two different regular urban-array models. The first model has a uniform building roof height, while the second model has a non-uniform roof height along each building's wall. The mean flow and concentration fields at the canyons' lateral openings confirm the findings of other studies that the buildings' roof-height variability at the intersections plays an important role in the dispersion of the traffic pollutants within the canyons. For the perpendicular wind, the non-uniform roof-height canyon appreciably removes or entrains the pollutant through its lateral openings, contrary to the uniform canyon, where the pollutant was removed primarily through the top. The analysis of the turbulent mass transport revealed that the coherent flow structures of the lateral momentum transport correlate with the ventilation processes at the lateral openings of all studied canyons. These flow structures coincide at the same areas and hence simultaneously transport the pollutant in opposite directions. - Highlights: • The pollutant transport strongly depends on the roof-height arrangement. • The non-uniform canyons also remove the pollutants through their lateral openings. • The higher the upstream wall, the more pollutant is removed through the top. • The lateral coherent structures correlate

  11. A DSP-based neural network non-uniformity correction algorithm for IRFPA

    Science.gov (United States)

    Liu, Chong-liang; Jin, Wei-qi; Cao, Yang; Liu, Xiu

    2009-07-01

    An effective neural network non-uniformity correction (NUC) algorithm based on DSP is proposed in this paper. The non-uniform response in infrared focal plane array (IRFPA) detectors produces corrupted images with a fixed-pattern noise(FPN).We introduced and analyzed the artificial neural network scene-based non-uniformity correction (SBNUC) algorithm. A design of DSP-based NUC development platform for IRFPA is described. The DSP hardware platform designed is of low power consumption, with 32-bit fixed point DSP TMS320DM643 as the kernel processor. The dependability and expansibility of the software have been improved by DSP/BIOS real-time operating system and Reference Framework 5. In order to realize real-time performance, the calibration parameters update is set at a lower task priority then video input and output in DSP/BIOS. In this way, calibration parameters updating will not affect video streams. The work flow of the system and the strategy of real-time realization are introduced. Experiments on real infrared imaging sequences demonstrate that this algorithm requires only a few frames to obtain high quality corrections. It is computationally efficient and suitable for all kinds of non-uniformity.

  12. Characterization and Processing of Non-Uniformities in Back-Illuminated CCDs

    Science.gov (United States)

    Lemm, Alia D.; Della-Rose, Devin J.; Maddocks, Sally

    2018-01-01

    In astronomical photometry, Charged Coupled Device (CCD) detectors are used to achieve high precision photometry and must be properly calibrated to correct for noise and pixel non-uniformities. Uncalibrated images may contain bias offset, dark current, bias structure and uneven illumination. In addition, standard data reduction is often not sufficient to “normalize” imagery to single-digit millimagnitude (mmag) precision. We are investigating an apparent non-uniformity, or interference pattern, in a back-illuminated sensor, the Alta U-47, attached to a DFM Engineering 41-cm Ritchey-Chrétien f/8 telescope. Based on the amplitude of this effect, we estimate that instrument magnitude peak-to-valley deviations of 50 mmag or more may result. Our initial testing strongly suggests that reflected skylight from high pressure sodium city lights may be the cause of this interference pattern. Our research goals are twofold: to fully characterize this non-uniformity and to determine the best method to remove this interference pattern from our reduced CCD images.

  13. Continuous-variable quantum key distribution in uniform fast-fading channels

    Science.gov (United States)

    Papanastasiou, Panagiotis; Weedbrook, Christian; Pirandola, Stefano

    2018-03-01

    We investigate the performance of several continuous-variable quantum key distribution protocols in the presence of uniform fading channels. These are lossy channels whose transmissivity changes according to a uniform probability distribution. We assume the worst-case scenario where an eavesdropper induces a fast-fading process, where she chooses the instantaneous transmissivity while the remote parties may only detect the mean statistical effect. We analyze coherent-state protocols in various configurations, including the one-way switching protocol in reverse reconciliation, the measurement-device-independent protocol in the symmetric configuration, and its extension to a three-party network. We show that, regardless of the advantage given to the eavesdropper (control of the fading), these protocols can still achieve high rates under realistic attacks, within reasonable values for the variance of the probability distribution associated with the fading process.

  14. Design of internally heat-integrated distillation column (HIDiC): Uniform heat transfer area versus uniform heat distribution

    Energy Technology Data Exchange (ETDEWEB)

    Suphanit, B. [Department of Chemical Engineering, Faculty of Engineering, King Mongkut' s University of Technology Thonburi, Pracha Utit Rd., Tungkru, Bangkok 10140 (Thailand)

    2010-03-15

    The internally heat-integrated distillation column (HIDiC) is a complex column configuration which is more energy efficient than the equivalent conventional column or the distillation column with direct vapor recompression scheme (VRC). Exploiting the heat integration between two diabatic sections operating at different pressures of the HIDiC can greatly enhance the energy performance of the system. On the other hand, the design and optimization of HIDiC is more difficult than those of the conventional distillation column or the column with VRC. The former involves many design parameters, and the most critical one is the pressure ratio between both diabatic sections. However, the heat distribution along the diabatic sections is also another significant factor not yet thoroughly investigated. In this work, two typical distribution schemes, i.e. uniform heat transfer area and uniform heat distribution, are studied by applying a novel approach to solve the simulation problem in Aspen Plus 2004.1. The comparison of both distributing schemes is discussed via two widely-used case studies, namely benzene-toluene separation and propylene-propane splitter. (author)

  15. The Ciliate Paramecium Shows Higher Motility in Non-Uniform Chemical Landscapes

    Science.gov (United States)

    Giuffre, Carl; Hinow, Peter; Vogel, Ryan; Ahmed, Tanvir; Stocker, Roman; Consi, Thomas R.; Strickler, J. Rudi

    2011-01-01

    We study the motility behavior of the unicellular protozoan Paramecium tetraurelia in a microfluidic device that can be prepared with a landscape of attracting or repelling chemicals. We investigate the spatial distribution of the positions of the individuals at different time points with methods from spatial statistics and Poisson random point fields. This makes quantitative the informal notion of “uniform distribution” (or lack thereof). Our device is characterized by the absence of large systematic biases due to gravitation and fluid flow. It has the potential to be applied to the study of other aquatic chemosensitive organisms as well. This may result in better diagnostic devices for environmental pollutants. PMID:21494596

  16. Attention operates uniformly throughout the classical receptive field and the surround

    Science.gov (United States)

    Verhoef, Bram-Ernst; Maunsell, John HR

    2016-01-01

    Shifting attention among visual stimuli at different locations modulates neuronal responses in heterogeneous ways, depending on where those stimuli lie within the receptive fields of neurons. Yet how attention interacts with the receptive-field structure of cortical neurons remains unclear. We measured neuronal responses in area V4 while monkeys shifted their attention among stimuli placed in different locations within and around neuronal receptive fields. We found that attention interacts uniformly with the spatially-varying excitation and suppression associated with the receptive field. This interaction explained the large variability in attention modulation across neurons, and a non-additive relationship among stimulus selectivity, stimulus-induced suppression and attention modulation that has not been previously described. A spatially-tuned normalization model precisely accounted for all observed attention modulations and for the spatial summation properties of neurons. These results provide a unified account of spatial summation and attention-related modulation across both the classical receptive field and the surround. DOI: http://dx.doi.org/10.7554/eLife.17256.001 PMID:27547989

  17. The Pierce diode with an external circuit: II, Non-uniform equilibria

    International Nuclear Information System (INIS)

    Lawson, W.S.

    1987-01-01

    The non-uniform (non-linear) equilibria of the classical (short circuit) Pierce diode and the extended (series RLC external circuit) Pierce diode are described theoretically, and explored via computer simulation. It is found that most equilibria are correctly predicted by theory, but that the continuous set of equilibria of the classical Pierce diode at α = 2π are not observed. The stability characteristics of the non-uniform equilibria are also worked out, and are consistent with the simulations. 8 refs., 22 figs., 3 tabs

  18. Whole-body voxel-based personalized dosimetry: Multiple voxel S-value approach for heterogeneous media with non-uniform activity distributions.

    Science.gov (United States)

    Lee, Min Sun; Kim, Joong Hyun; Paeng, Jin Chul; Kang, Keon Wook; Jeong, Jae Min; Lee, Dong Soo; Lee, Jae Sung

    2017-12-14

    Personalized dosimetry with high accuracy is becoming more important because of the growing interests in personalized medicine and targeted radionuclide therapy. Voxel-based dosimetry using dose point kernel or voxel S-value (VSV) convolution is available. However, these approaches do not consider medium heterogeneity. Here, we propose a new method for whole-body voxel-based personalized dosimetry for heterogeneous media with non-uniform activity distributions, which is referred to as the multiple VSV approach. Methods: The multiple numbers (N) of VSVs for media with different densities covering the whole-body density ranges were used instead of using only a single VSV for water. The VSVs were pre-calculated using GATE Monte Carlo simulation; those were convoluted with the time-integrated activity to generate density-specific dose maps. Computed tomography-based segmentation was conducted to generate binary maps for each density region. The final dose map was acquired by the summation of N segmented density-specific dose maps. We tested several sets of VSVs with different densities: N = 1 (single water VSV), 4, 6, 8, 10, and 20. To validate the proposed method, phantom and patient studies were conducted and compared with direct Monte Carlo, which was considered the ground truth. Finally, patient dosimetry (10 subjects) was conducted using the multiple VSV approach and compared with the single VSV and organ-based dosimetry approaches. Errors at the voxel- and organ-levels were reported for eight organs. Results: In the phantom and patient studies, the multiple VSV approach showed significant improvements regarding voxel-level errors, especially for the lung and bone regions. As N increased, voxel-level errors decreased, although some overestimations were observed at lung boundaries. In the case of multiple VSVs ( N = 8), we achieved voxel-level errors of 2.06%. In the dosimetry study, our proposed method showed much improved results compared to the single VSV and

  19. Experimental study on occupant's thermal responses under the non-uniform conditions in vehicle cabin during the heating period

    Science.gov (United States)

    Zhang, Wencan; Chen, Jiqing; Lan, Fengchong

    2014-03-01

    The existing investigations on thermal comfort mostly focus on the thermal environment conditions, especially of the air-flow field and the temperature distributions in vehicle cabin. Less attention appears to direct to the thermal comfort or thermal sensation of occupants, even to the relationship between thermal conditions and thermal sensation. In this paper, a series of experiments were designed and conducted for understanding the non-uniform conditions and the occupant's thermal responses in vehicle cabin during the heating period. To accurately assess the transient temperature distribution in cabin in common daily condition, the air temperature at a number of positions is measured in a full size vehicle cabin under natural winter environment in South China by using a discrete thermocouples network. The occupant body is divided into nine segments, the skin temperature at each segment and the occupant's local thermal sensation at the head, body, upper limb and lower limb are monitored continuously. The skin temperature is observed by using a discrete thermocouples network, and the local thermal sensation is evaluated by using a seven-point thermal comfort survey questionnaire proposed by American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc(ASHRAE) Standard. The relationship between the skin temperature and the thermal sensation is discussed and regressed by statistics method. The results show that the interior air temperature is highly non-uniform over the vehicle cabin. The locations where the occupants sit have a significant effect on the occupant's thermal responses, including the skin temperature and the thermal sensation. The skin temperature and thermal sensation are quite different between body segments due to the effect of non-uniform conditions, clothing resistance, and the human thermal regulating system. A quantitative relationship between the thermal sensation and the skin temperature at each body segment of occupant in

  20. Highly Uniform Carbon Nanotube Field-Effect Transistors and Medium Scale Integrated Circuits.

    Science.gov (United States)

    Chen, Bingyan; Zhang, Panpan; Ding, Li; Han, Jie; Qiu, Song; Li, Qingwen; Zhang, Zhiyong; Peng, Lian-Mao

    2016-08-10

    Top-gated p-type field-effect transistors (FETs) have been fabricated in batch based on carbon nanotube (CNT) network thin films prepared from CNT solution and present high yield and highly uniform performance with small threshold voltage distribution with standard deviation of 34 mV. According to the property of FETs, various logical and arithmetical gates, shifters, and d-latch circuits were designed and demonstrated with rail-to-rail output. In particular, a 4-bit adder consisting of 140 p-type CNT FETs was demonstrated with higher packing density and lower supply voltage than other published integrated circuits based on CNT films, which indicates that CNT based integrated circuits can reach to medium scale. In addition, a 2-bit multiplier has been realized for the first time. Benefitted from the high uniformity and suitable threshold voltage of CNT FETs, all of the fabricated circuits based on CNT FETs can be driven by a single voltage as small as 2 V.

  1. A dynamic model of gas flow in a non-uniform pipe

    International Nuclear Information System (INIS)

    Mensah, S.; Lepp, R.M.

    1979-08-01

    A gas-line model, based on the analysis of compressible flow with friction, has been developed to describe the dynamics of gas flow in a non-uniform line, i.e. one comprising segments of different lengths and diameters. Acoustic wave analysis was used in a novel way, by considering the line as a cascaded connection of uniform pipes separated by discontinuities. The transmission matrix representing this non-uniform line is the product of the matrices for each element in the system. To facilitate implementation of the theoretical model on a hybrid computer, modal approximatons to its transfer functions were derived. Both models were validated against experimental data. (author)

  2. Heat transfer improvement due to the imposition of non-uniform wall heating for in-tube laminar forced convection

    International Nuclear Information System (INIS)

    Hajmohammadi, M.R.; Poozesh, S.; Rahmani, M.; Campo, A.

    2013-01-01

    This paper explores the bearing that a non-uniform distribution of heat flux used as a wall boundary condition exerts on the heat transfer improvement in a round pipe. Because the overall heat load is considered fixed, the heat transfer improvement is viewed through a reduction in the maximum temperature (‘hot spot’) by imposing optimal distribution of heat flux. Two cases are studied in detail 1) fully developed and 2) developing flow. Peak temperatures in the heated pipe wall are calculated via an analytical approach for the fully developed case, while a numerical simulation based on CFD is employed for the developing case. By relaxing the heat flux distribution on the pipe wall, the numerical results imply that the optimum distribution of heat flux, which minimizes the peak temperatures corresponds with the ‘descending’ distribution. Given that the foregoing approach is quite different from the ‘ascending’ heat flux distribution recommended in the literature by means of the entropy generation minimization (EGM) method, it is inferred that the optimization of heat transfer and fluid flow, in comparison with the thermodynamic optimization, may bring forth quite different guidelines for the designs of thermal systems under the same constraints and circumstances. -- Highlights: • Considered the bearing of non-uniform distribution of heat flux on the hot spots. • Determined the optimal distribution of heat flux that minimizes the hot spots. • Results are compared with those obtained by EGM method

  3. Non-uniformity measurements of PbWO4 crystals

    International Nuclear Information System (INIS)

    Depasse, P.; Ernenwein, J.P.; Ille, B.; Martin, F.; Rosset, C.; Zach, F.

    1998-11-01

    Two independent methods have been used to measure the longitudinal non-uniformity scintillation response of 3 different (23-cm long) PbWO 4 crystals. The first one is the classical 60 Co source method. The source is collimated along the crystal, each 1,5-cm, and the scintillation signal is measured with a photomultiplier (a hybrid photomultiplier in our case). The second one is the use of cosmic particles (Minimum Ionizing Particles). A cosmic bench allows reconstructing the track of the MIP's and thus the energy deposit with the help of a full GEANT simulation of the setup. Variations of E along the crystal artificially cut in 1,5-cm divisions, leads to determine the non-uniformity. The conclusion is that both methods agree quite well. Furthermore, a good estimation of crystal light yield can be obtained. (author)

  4. Laser investigation of the non-uniformity of fluorescent species in dental enamel

    Science.gov (United States)

    Tran, Stephanie U.; Ridge, Jeremy S.; Nelson, Leonard Y.; Seibel, Eric J.

    In the present study, artificial type I and type II erosions were created on dental specimen using acetic acid and EDTA respectively. Specimens were prepared by etching extracted teeth samples in acid to varying degrees, after which the absolute fluorescence intensity ratio of the etched enamel relative to sound enamel was recorded for each specimen using 405 and 532 nm laser excitation. Results showed differences in the fluorescence ratio of etched to sound enamel for type I and II erosions. These findings suggest a non-uniform distribution of fluorescent species in the interprismatic region as compared to the prismatic region.

  5. Uniform convergence of the empirical spectral distribution function

    NARCIS (Netherlands)

    Mikosch, T; Norvaisa, R

    1997-01-01

    Let X be a linear process having a finite fourth moment. Assume F is a class of square-integrable functions. We consider the empirical spectral distribution function J(n,X) based on X and indexed by F. If F is totally bounded then J(n,X) satisfies a uniform strong law of large numbers. If, in

  6. Experience in treatment of the radiation syndrome in accident victims exposed with non-uniform distribution of the dose within a body

    International Nuclear Information System (INIS)

    Guskova, A.; Barabanova, A

    1996-01-01

    Experience in diagnosis and treatment of radiation accident victims undergone to radiation expose with non-uniform distribution of the dose within a body is presented and the most significant features of medical management of such patients are discussed. The term 'compound radiation injure' is proposed to use for this form of radiation disease. Treatment of compound radiation injure demands a participation of very qualified specialists. The first medical aid and management should include careful body surface monitoring. Beside daily haematological observation and cytogenetic study with corresponding treatment, careful observation and registration of skin reaction are necessary. Some features of treatment are the following: more early administration of anti infection means, including isolation in sterile room, timely surgical intervention, prophylacsis and treatment of endorganic intoxication improving of microcirculation, long time follow up study with pathogenic therapy. (author)

  7. Sharp lower bounds on the extractable randomness from non-uniform sources

    NARCIS (Netherlands)

    Skoric, B.; Obi, C.; Verbitskiy, E.A.; Schoenmakers, B.

    2011-01-01

    Extraction of uniform randomness from (noisy) non-uniform sources is an important primitive in many security applications, e.g. (pseudo-)random number generators, privacy-preserving biometrics, and key storage based on Physical Unclonable Functions. Generic extraction methods exist, using universal

  8. Developing semi-analytical solution for multiple-zone transient storage model with spatially non-uniform storage

    Science.gov (United States)

    Deng, Baoqing; Si, Yinbing; Wang, Jia

    2017-12-01

    Transient storages may vary along the stream due to stream hydraulic conditions and the characteristics of storage. Analytical solutions of transient storage models in literature didn't cover the spatially non-uniform storage. A novel integral transform strategy is presented that simultaneously performs integral transforms to the concentrations in the stream and in storage zones by using the single set of eigenfunctions derived from the advection-diffusion equation of the stream. The semi-analytical solution of the multiple-zone transient storage model with the spatially non-uniform storage is obtained by applying the generalized integral transform technique to all partial differential equations in the multiple-zone transient storage model. The derived semi-analytical solution is validated against the field data in literature. Good agreement between the computed data and the field data is obtained. Some illustrative examples are formulated to demonstrate the applications of the present solution. It is shown that solute transport can be greatly affected by the variation of mass exchange coefficient and the ratio of cross-sectional areas. When the ratio of cross-sectional areas is big or the mass exchange coefficient is small, more reaches are recommended to calibrate the parameter.

  9. Maximum Power Point tracking algorithm based on I-V characteristic of PV array under uniform and non-uniform conditions

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Iman-Eini, H.; Asaei, B.

    2012-01-01

    This paper presents a new algorithm based on characteristic equation of solar cells to determine the Maximum Power Point (MPP) of PV modules under partially shaded conditions (PSC). To achieve this goal, an analytic condition is introduced to determine uniform or non-uniform atmospheric condition...

  10. Tumor and normal tissue responses to fractioned non-uniform dose delivery

    Energy Technology Data Exchange (ETDEWEB)

    Kaellman, P; Aegren, A; Brahme, A [Karolinska Inst., Stockholm (Sweden). Dept. of Radiation Physics

    1996-08-01

    The volume dependence of the radiation response of a tumor is straight forward to quantify because it depends primarily on the eradication of all its clonogenic cells. A tumor therefore has a parallel organization as any surviving clonogen in principle can repopulate the tumor. The difficulty with the response of the tumor is instead to know the density and sensitivity distribution of the most resistant clonogenic cells. The increase in the 50% tumor control dose and the decrease in the maximum normalized slope of the dose response relation, {gamma}, in presence of small compartments of resistant tumor cells have therefore been quantified to describe their influence on the dose response relation. Injury to normal tissue is a much more complex and gradual process. It depends on earlier effects induced long before depletion of the differentiated and clonogenic cells that in addition may have a complex structural and functional organization. The volume dependence of the dose response relation of normal tissues is therefore described here by the relative seriality, s, of the infrastructure of the organ. The model can also be generalized to describe the response of heterogeneous tissues to non uniform dose distributions. The new model is compared with clinical and experimental data on normal tissue response, and shows good agreement both with regard to the shape of dose response relation and the volume dependence of the isoeffect dose. The response of tumors and normal tissues are quantified for arbitrary dose fractionations using the linear quadratic cell survival parameters {alpha} and {beta}. The parameters of the dose response relation are derived both for a constant dose per fraction and a constant number of dose fractions, thus in the latter case accounting also for non uniform dose delivery. (author). 26 refs, 4 figs.

  11. A comparison on the heat load of HTS current leads with respect to uniform and non-uniform cross-sectional areas

    Energy Technology Data Exchange (ETDEWEB)

    Han, Seung Hak; Nam, Seok Ho; Lee, Je Yull; Song, Seung Hyun; Jeon, Hae Ryong; Baek, Geon Woo; Ko, Tae Kuk [Yonsei University, Seoul (Korea, Republic of); Kang, Hyoung Ku [Korea National University of Transportation, Chungju (Korea, Republic of)

    2017-09-15

    Current lead is a device that connects the power supply and superconducting magnets. High temperature superconductor (HTS) has lower thermal conductivity and higher current density than normal metal. For these reasons, the heat load can be reduced by replacing the normal metal of the current lead with the HTS. Conventional HTS current lead has same cross-sectional area in the axial direction. However, this is over-designed at the cold-end (4.2 K) in terms of current. The heat load can be reduced by reducing this part because the heat load is proportional to the cross-sectional area. Therefore, in this paper, heat load was calculated from the heat diffusion equation of HTS current leads with uniform and non-uniform cross-sectional areas. The cross-sectional area of the warm-end (65K) is designed considering burnout time when cooling system failure occurs. In cold-end, Joule heat and heat load due to current conduction occurs at the same time, so the cross-sectional area where the sum of the two heat is minimum is obtained. As a result of simulation, current leads for KSTAR TF coils with uniform and non-uniform cross-sectional areas were designed, and it was confirmed that the non-uniform cross-sectional areas could further reduce the heat load.

  12. Non-Uniform Dose Mapping Controlled by Modulated Vertical and Horizontal Scans

    International Nuclear Information System (INIS)

    Ninomiya, S.; Kimura, Y.; Kudo, T.; Ochi, A.; Toda, R.; Tsukihara, M.; Sato, F.; Fuse, G.; Ueno, K.; Sugitani, M.

    2008-01-01

    Since geometries of semi-conductor devices continue to shrink, the requirement for each process becomes severer to keep uniformity of electrical parameters of the semi-conductor devices. A larger wafer also causes larger variations. Thus it has been strongly required for ion implantation process to compensate for the variations from other processes because of its good dose controllability. A newly developed mapping of intentional non-uniform dosage system, which is named 'MIND system', is implemented in SEN's single-wafer-type implanters. The MIND system controls both horizontal and vertical scan speed simultaneously. Intentional two-dimensional non-uniform profiles of sheet resistance, such as concentric and eccentric profiles, are obtained only by single-step ion implantation.

  13. Non-similar solutions for unsteady flow over a yawed cylinder with non-uniform mass transfer through a slot

    Directory of Open Access Journals (Sweden)

    G. Revathi

    2014-12-01

    Full Text Available Non-similar solutions are found numerically to a system of coupled non-linear partial differential equations indicating, unsteady laminar water boundary layer flow over yawed cylinder using implicit finite difference scheme along with Quasi-linearization technique. The fluid properties such as viscosity and Prandtl number are considered as an inverse function of temperature. Unsteadiness is caused by upstream velocity in and directions and non-uniform mass transfer (suction/injection which is applied through slot on the surface of the geometry. The effect of yaw angle, variable fluid properties and non-uniform mass transfer on skin friction and heat transfer coefficients is analyzed. It is found that non-uniform slot suction and downstream movement of the slot cause the point of vanishing skin friction moves downstream, but non-uniform slot injection produces the opposite result of that corresponding to the suction case. When the yaw angle increases, both the skin friction coefficient in the – direction and the heat transfer coefficient decrease but the skin friction coefficient in the – direction increases for all times. The effect of the yaw angle is very little on the point of vanishing skin friction.

  14. Uniform electromagnetic field as viscous medium for moving particles

    International Nuclear Information System (INIS)

    Amusia, M.Ya.; Baltenkov, A.S.; Felfli, Z.; Msezane, A.Z.; Voitkiv, A.B.

    2002-01-01

    The mechanism of transverse radiation viscosity acting on free charges, atomic, and small macroscopic particles in uniform electromagnetic fields is analyzed. It is shown that in the process of light scattering by these particles, besides the force accelerating them in the direction of propagation of the radiation, there is a force in the transverse direction slowing them down. The general expression for this force is obtained. It is considered how this force can influence: (i) the motion of ultrarelativistic electrons in transverse photon fluxes; (ii) the behavior of a beam of nonrelativistic electrons moving in a copropagating uniform electromagnetic field; (iii) the transverse motion of atoms under the action of resonant radiation and (iv) the motion of small macroscopic particles

  15. Photocathode non-uniformity contribution to the energy resolution of scintillators

    International Nuclear Information System (INIS)

    Mottaghian, M.; Koohi-Fayegh, R.; Ghal-Eh, N.; Etaati, G. R.

    2010-01-01

    This paper introduces the basics of the light transport simulation in scintillators and the wavelength-dependencies in the process. The non-uniformity measurement of the photocathode surface is undertaken, showing that for the photocathode used in this study the quantum efficiency falls to about 4% of its maximum value, especially in areas far from the centre. The wavelength-and position-dependent quantum efficiency is implemented in the Monte Carlo light transport code, showing that, the contribution of the photocathode non-uniformity to the energy resolution is estimated to be around 18%, when all position-and wavelength-dependencies are included. (authors)

  16. Leveraging Non-Uniform Resources for Parallel Query Processing

    DEFF Research Database (Denmark)

    Mayr, Tobias; Bonnet, Philippe; Gehrke, Johannes

    2003-01-01

    Modular clusters are now composed of non- uniform nodes with different CPUs, disks or network cards so that customers can adapt the cluster configuration to the changing technologies and to their changing needs. This challenges dataflow parallelism as the primary load balancing technique of exist...

  17. Nonconformal scalar field in uniform isotropic space and the method of Hamiltonian diagonalization

    International Nuclear Information System (INIS)

    Pavlov, Yu.V.

    2001-01-01

    One diagonalized metric Hamiltonian of scalar field with arbitrary relation with curvature in N-dimensional uniform isotropic space. One derived spectrum of energies of the appropriate quasi-particles. One calculated energy of quasi-particle appropriate to the canonical Hamiltonian diagonal shape. One structured a modified tensor of energy-pulse with the following features. In case of conformal scalar field it coincides with the metric tensor of energy-pulse. When it is diagonalized the energies of the appropriate particles of nonconformal field are equal to oscillation frequency and the number of such particles produced in non-stationary metric is the finite one. It is shown that Hamiltonian calculated on the basis of the modified tensor of energy-pulse may be derived as a canonical one at certain selection of variables [ru

  18. An experimental comparison between forced convection burn-out in freon 12 flowing vertically upwards through uniformly and non-uniformly heated round tubes

    International Nuclear Information System (INIS)

    Stevens, G.F.; Elliott, D.F.; Wood, R.W.

    1965-05-01

    Some correlations of forced convection burn-out data are based on the approximate linearity of the relationship between burn-out heat flux and the channel-averaged quality at the burn-out point. These correlations perform satisfactorily on data obtained from uniformly heated configurations. Therefore the further inference is sometimes made that the burn-out heat flux is uniquely related to the quality, and that the burn-out in non-uniformly heated configurations can be calculated from measurements made with uniform heating. This report presents burn-out data for Freon 12 flowing vertically upwards through both uniformly and non-uniformly heated round tubes. This data shows that the quality at burn-out does depend on the heat flux profile, and that the inference mentioned above is not justified. (author)

  19. Linear velocity fields in non-Gaussian models for large-scale structure

    Science.gov (United States)

    Scherrer, Robert J.

    1992-01-01

    Linear velocity fields in two types of physically motivated non-Gaussian models are examined for large-scale structure: seed models, in which the density field is a convolution of a density profile with a distribution of points, and local non-Gaussian fields, derived from a local nonlinear transformation on a Gaussian field. The distribution of a single component of the velocity is derived for seed models with randomly distributed seeds, and these results are applied to the seeded hot dark matter model and the global texture model with cold dark matter. An expression for the distribution of a single component of the velocity in arbitrary local non-Gaussian models is given, and these results are applied to such fields with chi-squared and lognormal distributions. It is shown that all seed models with randomly distributed seeds and all local non-Guassian models have single-component velocity distributions with positive kurtosis.

  20. Hydrodynamic and thermal mechanisms of filtration combustion inclinational instability based on non-uniform distribution of initial preheating temperature

    Science.gov (United States)

    Xia, Yongfang; Shi, Junrui; Xu, Youning; Ma, Rui

    2018-03-01

    Filtration combustion (FC) is one style of porous media combustion with inert matrix, in which the combustion wave front propagates, only downstream or reciprocally. In this paper, we investigate the FC flame front inclinational instability of lean methane/air mixtures flowing through a packed bed as a combustion wave front perturbation of the initial preheating temperature non-uniformity is assumed. The predicted results show that the growth rate of the flame front inclinational angle is proportional to the magnitude of the initial preheating temperature difference. Additionally, depending on gas inlet gas velocity and equivalence ratio, it is demonstrated that increase of gas inlet gas velocity accelerates the FC wave front deformation, and the inclinational instability evolves faster at lower equivalence ratio. The development of the flame front inclinational angle may be regarded as a two-staged evolution, which includes rapid increase, and approaching maximum value of inclinational angle due to the quasi-steady condition of the combustion system. The hydrodynamic and thermal mechanisms of the FC inclinational instability are analyzed. Consequently, the local propagation velocity of the FC wave front is non-uniform to result in the development of inclinational angle at the first stage of rapid increase.

  1. The characteristics on dose distribution of a large field

    International Nuclear Information System (INIS)

    Lee, Sang Rok; Jeong, Deok Yang; Lee, Btiung Koo; Kwon, Young Ho

    2003-01-01

    In special cases of Total Body Irradiation(TBI), Half Body Irradiation(HBI), Non-Hodgkin's lymphoma, E-Wing's sarcoma, lymphosarcoma and neuroblastoma a large field can be used clinically. The dose distribution of a large field can use the measurement result which gets from dose distribution of a small field (standard SSD 100 cm, size of field under 40 x 40 cm 2 ) in the substitution which always measures in practice and it will be able to calibrate. With only the method of simple calculation, it is difficult to know the dose and its uniformity of actual body region by various factor of scatter radiation. In this study, using Multidata Water Phantom from standard SSD 100 cm according to the size change of field, it measures the basic parameter (PDD,TMR,Output,Sc,Sp) From SSD 180 cm (phantom is to the bottom vertically) according to increasing of a field, it measures a basic parameter. From SSD 350 cm (phantom is to the surface of a wall, using small water phantom. which includes mylar capable of horizontal beam's measurement) it measured with the same method and compared with each other. In comparison with the standard dose data, parameter which measures between SSD 180 cm and 350 cm, it turned out there was little difference. The error range is not up to extent of the experimental error. In order to get the accurate data, it dose measures from anthropomorphous phantom or for this objective the dose measurement which is the possibility of getting the absolute value which uses the unlimited phantom that is devised especially is demanded. Additionally, it needs to consider ionization chamber use of small volume and stem effect of cable by a large field.

  2. Influence of inclined Lorentz force on micropolar fluids in a square cavity with uniform and nonuniform heated thin plate

    Energy Technology Data Exchange (ETDEWEB)

    Periyadurai, K. [Department of Mathematics, Bharathiar University, Coimbatore 641046, Tamil Nadu (India); Muthtamilselvan, M., E-mail: muthtamill@yahoo.co.in [Department of Mathematics, Bharathiar University, Coimbatore 641046, Tamil Nadu (India); Doh, Deog-Hee [Division of Mechanical Engineering, College of Engineering,Korea Maritime Ocean University, Busan 606781 (Korea, Republic of)

    2016-12-15

    In the present study, the effect of inclined magnetic field on natural convection of micro-polar fluid in a square cavity with uniform and nonuniform heated thin plate built in centrally is investigated numerically. The vertical walls are cooled while the top and bottom walls are insulated. The thin plate is assumed to be isothermal with a linearly varying temperature. The governing equations were solved by finite volume method using second order central difference scheme and upwind differencing scheme. The numerical investigation is carried out for different governing parameters namely, the Hartmann number, inclination angle of magnetic field, Rayleigh number, vortex viscosity and source non-uniformity parameters. The result shows that the heat transfer rate is decreased when increasing Hartmann number, inclination angle of magnetic field and vortex viscosity parameter. It is found that the non-uniformity parameter affects the fluid flow and temperature distribution especially for the high Rayleigh numbers. Finally, the overall heat transfer rate of micro-polar fluids is found to be smaller than that of Newtonian fluid. - Highlights: • We investigate the effect of inclined magnetic field on micropolar fluid in a cavity. • The effects of uniform and non-uniform heated plate are studied. • The present numerical results are compared with the experimental results. • The addition of vortex viscosity parameter declines the heat transfer performance. • The high heat transfer rate occurs in the vertical plate compared to the horizontal one.

  3. The segmented non-uniform dielectric module design for uniformity control of plasma profile in a capacitively coupled plasma chamber

    International Nuclear Information System (INIS)

    Xia, Huanxiong; Xiang, Dong; Yang, Wang; Mou, Peng

    2014-01-01

    Low-temperature plasma technique is one of the critical techniques in IC manufacturing process, such as etching and thin-film deposition, and the uniformity greatly impacts the process quality, so the design for the plasma uniformity control is very important but difficult. It is hard to finely and flexibly regulate the spatial distribution of the plasma in the chamber via controlling the discharge parameters or modifying the structure in zero-dimensional space, and it just can adjust the overall level of the process factors. In the view of this problem, a segmented non-uniform dielectric module design solution is proposed for the regulation of the plasma profile in a CCP chamber. The solution achieves refined and flexible regulation of the plasma profile in the radial direction via configuring the relative permittivity and the width of each segment. In order to solve this design problem, a novel simulation-based auto-design approach is proposed, which can automatically design the positional sequence with multi independent variables to make the output target profile in the parameterized simulation model approximate the one that users preset. This approach employs an idea of quasi-closed-loop control system, and works in an iterative mode. It starts from initial values of the design variable sequences, and predicts better sequences via the feedback of the profile error between the output target profile and the expected one. It never stops until the profile error is narrowed in the preset tolerance

  4. Physical optics in a uniform gravitational field

    Science.gov (United States)

    Hacyan, Shahen

    2012-01-01

    The motion of a (quasi-)plane wave in a uniform gravitational field is studied. It is shown that the energy of an elliptically polarized wave does not propagate along a geodesic, but in a direction that is rotated with respect to the gravitational force. The similarity with the walk-off effect in anisotropic crystals or the optical Magnus effect in inhomogeneous media is pointed out.

  5. Theoretical Analysis of Unit Friction Force Working on the Metal Contact Surface with the Roll Change during Feedstock with Non-Uniform Temperature Distribution Rolling Process

    Directory of Open Access Journals (Sweden)

    Sygut P.

    2016-06-01

    Full Text Available The paper presents the results of theoretical studies influence of non-uniform temperature distribution along the feedstock length to the unit friction force working on the metal contact surface with the roll change during the round bars 70 mm in diameter continuous rolling process. This value is one of the major factors affecting the grooves wear during the rolling process. The studies were carried out based on the actual engineering data for 160 × 160 mm square cross-section feedstock of steel S355J0. Numerical modelling of the rolling process was performed using Forge2008®, a finite-element based computer program.

  6. Modelling of the reactive sputtering process with non-uniform discharge current density and different temperature conditions

    International Nuclear Information System (INIS)

    Vasina, P; Hytkova, T; Elias, M

    2009-01-01

    The majority of current models of the reactive magnetron sputtering assume a uniform shape of the discharge current density and the same temperature near the target and the substrate. However, in the real experimental set-up, the presence of the magnetic field causes high density plasma to form in front of the cathode in the shape of a toroid. Consequently, the discharge current density is laterally non-uniform. In addition to this, the heating of the background gas by sputtered particles, which is usually referred to as the gas rarefaction, plays an important role. This paper presents an extended model of the reactive magnetron sputtering that assumes the non-uniform discharge current density and which accommodates the gas rarefaction effect. It is devoted mainly to the study of the behaviour of the reactive sputtering rather that to the prediction of the coating properties. Outputs of this model are compared with those that assume uniform discharge current density and uniform temperature profile in the deposition chamber. Particular attention is paid to the modelling of the radial variation of the target composition near transitions from the metallic to the compound mode and vice versa. A study of the target utilization in the metallic and compound mode is performed for two different discharge current density profiles corresponding to typical two pole and multipole magnetics available on the market now. Different shapes of the discharge current density were tested. Finally, hysteresis curves are plotted for various temperature conditions in the reactor.

  7. Field signatures of non-Fickian transport processes: transit time distributions, spatial correlations, reversibility and hydrogeophysical imaging

    Science.gov (United States)

    Le Borgne, T.; Kang, P. K.; Guihéneuf, N.; Shakas, A.; Bour, O.; Linde, N.; Dentz, M.

    2015-12-01

    Non-Fickian transport phenomena are observed in a wide range of scales across hydrological systems. They are generally manifested by a broad range of transit time distributions, as measured for instance in tracer breakthrough curves. However, similar transit time distributions may be caused by different origins, including broad velocity distributions, flow channeling or diffusive mass transfer [1,2]. The identification of these processes is critical for defining relevant transport models. How can we distinguish the different origins of non-Fickian transport in the field? In this presentation, we will review recent experimental developments to decipher the different causes of anomalous transport, based on tracer tests performed at different scales in cross borehole and push pull conditions, and time lapse hydrogeophysical imaging of tracer motion [3,4]. References:[1] de Anna-, P., T. Le Borgne, M. Dentz, A. M. Tartakovsky, D. Bolster, P. Davy (2013) Flow Intermittency, Dispersion and Correlated Continuous Time Random Walks in Porous Media, Phys. Rev. Lett., 110, 184502 [2] Le Borgne T., Dentz M., and Carrera J. (2008) Lagrangian Statistical Model for Transport in Highly Heterogeneous Velocity Fields. Phys. Rev. Lett. 101, 090601 [3] Kang, P. K., T. Le Borgne, M. Dentz, O. Bour, and R. Juanes (2015), Impact of velocity correlation and distribution on transport in fractured media : Field evidence and theoretical model, Water Resour. Res., 51, 940-959 [4] Dorn C., Linde N., Le Borgne T., O. Bour and L. Baron (2011) Single-hole GPR reflection imaging of solute transport in a granitic aquifer Geophys. Res. Lett. Vol.38, L08401

  8. Development of the systems for uniform target irradiation

    International Nuclear Information System (INIS)

    Voronin, A.Yu.; Garanin, S.G.; Derkach, V.N.; Zhidkov, N.V.; Kravchenko, A.G.; Petrazhitskaya, N.A.; Starodubtsev, K.V.; Sukharev, S.A.; Shnyagin, R.A.

    2010-01-01

    Complete text of publication follows. The new devices have been developed for laser beams homogenizing in the focal spot - multi-component lens raster and raster with the edges smoothing phase mask. The envelope non-uniformity of -4 radians. Investigation into the temporary-spatial smoothing with the use of low-density foams with the density less than the critical one is still in progress. Experiments on the foams with the density of 1-2.3 mg/cm 3 , thickness of 100-200 μm, and the cells' sizes up to the tens of micrometers were carried out with the radiation wavelength of 0.657 μm. The RMS non-uniformity < 5% has been found for the beam passed through the foam. The non-uniformity is evenly distributed over the spatial frequency spectrum. The induced divergence of radiation is measured to be 0.35 radian. The frequency of the rearranged speckled field of about 2 THz was obtained. The beam smoothing was recorded from the start of pulse of radiation, had the duration up to 1 ns, and the width of the radiation spectrum was about 30 A. The work was performed in part under the sponsorship of the RFFI (grants No. 09-02-12157-ofi-m and No. 09-02-97095-r-povolzh'ye-a) and grant of the President of the RF to leading scientific schools No. 65192.2010.2.

  9. Quantitative SPECT reconstruction for brain distribution with a non-uniform attenuation using a regularizing method

    International Nuclear Information System (INIS)

    Soussaline, F.; Bidaut, L.; Raynaud, C.; Le Coq, G.

    1983-06-01

    An analytical solution to the SPECT reconstruction problem, where the actual attenuation effect can be included, was developped using a regularizing iterative method (RIM). The potential of this approach in quantitative brain studies when using a tracer for cerebrovascular disorders is now under evaluation. Mathematical simulations for a distributed activity in the brain surrounded by the skull and physical phantom studies were performed, using a rotating camera based SPECT system, allowing the calibration of the system and the evaluation of the adapted method to be used. On the simulation studies, the contrast obtained along a profile, was less than 5%, the standard deviation 8% and the quantitative accuracy 13%, for a uniform emission distribution of mean = 100 per pixel and a double attenuation coefficient of μ = 0.115 cm -1 and 0.5 cm -1 . Clinical data obtained after injection of 123 I (AMPI) were reconstructed using the RIM without and with cerebrovascular diseases or lesion defects. Contour finding techniques were used for the delineation of the brain and the skull, and measured attenuation coefficients were assumed within these two regions. Using volumes of interest, selected on homogeneous regions on an hemisphere and reported symetrically, the statistical uncertainty for 300 K events in the tomogram was found to be 12%, the index of symetry was of 4% for normal distribution. These results suggest that quantitative SPECT reconstruction for brain distribution is feasible, and that combined with an adapted tracer and an adequate model physiopathological parameters could be extracted

  10. A Non-Uniformly Under-Sampled Blade Tip-Timing Signal Reconstruction Method for Blade Vibration Monitoring

    Directory of Open Access Journals (Sweden)

    Zheng Hu

    2015-01-01

    Full Text Available High-speed blades are often prone to fatigue due to severe blade vibrations. In particular, synchronous vibrations can cause irreversible damages to the blade. Blade tip-timing methods (BTT have become a promising way to monitor blade vibrations. However, synchronous vibrations are unsuitably monitored by uniform BTT sampling. Therefore, non-equally mounted probes have been used, which will result in the non-uniformity of the sampling signal. Since under-sampling is an intrinsic drawback of BTT methods, how to analyze non-uniformly under-sampled BTT signals is a big challenge. In this paper, a novel reconstruction method for non-uniformly under-sampled BTT data is presented. The method is based on the periodically non-uniform sampling theorem. Firstly, a mathematical model of a non-uniform BTT sampling process is built. It can be treated as the sum of certain uniform sample streams. For each stream, an interpolating function is required to prevent aliasing in the reconstructed signal. Secondly, simultaneous equations of all interpolating functions in each sub-band are built and corresponding solutions are ultimately derived to remove unwanted replicas of the original signal caused by the sampling, which may overlay the original signal. In the end, numerical simulations and experiments are carried out to validate the feasibility of the proposed method. The results demonstrate the accuracy of the reconstructed signal depends on the sampling frequency, the blade vibration frequency, the blade vibration bandwidth, the probe static offset and the number of samples. In practice, both types of blade vibration signals can be particularly reconstructed by non-uniform BTT data acquired from only two probes.

  11. Nonlinear Dynamics of Non-uniform Current-Vortex Sheets in Magnetohydrodynamic Flows

    Science.gov (United States)

    Matsuoka, C.; Nishihara, K.; Sano, T.

    2017-04-01

    A theoretical model is proposed to describe fully nonlinear dynamics of interfaces in two-dimensional MHD flows based on an idea of non-uniform current-vortex sheet. Application of vortex sheet model to MHD flows has a crucial difficulty because of non-conservative nature of magnetic tension. However, it is shown that when a magnetic field is initially parallel to an interface, the concept of vortex sheet can be extended to MHD flows (current-vortex sheet). Two-dimensional MHD flows are then described only by a one-dimensional Lagrange parameter on the sheet. It is also shown that bulk magnetic field and velocity can be calculated from their values on the sheet. The model is tested by MHD Richtmyer-Meshkov instability with sinusoidal vortex sheet strength. Two-dimensional ideal MHD simulations show that the nonlinear dynamics of a shocked interface with density stratification agrees fairly well with that for its corresponding potential flow. Numerical solutions of the model reproduce properly the results of the ideal MHD simulations, such as the roll-up of spike, exponential growth of magnetic field, and its saturation and oscillation. Nonlinear evolution of the interface is found to be determined by the Alfvén and Atwood numbers. Some of their dependence on the sheet dynamics and magnetic field amplification are discussed. It is shown by the model that the magnetic field amplification occurs locally associated with the nonlinear dynamics of the current-vortex sheet. We expect that our model can be applicable to a wide variety of MHD shear flows.

  12. Enceladus's crust as a non-uniform thin shell: I tidal deformations

    Science.gov (United States)

    Beuthe, Mikael

    2018-03-01

    The geologic activity at Enceladus's south pole remains unexplained, though tidal deformations are probably the ultimate cause. Recent gravity and libration data indicate that Enceladus's icy crust floats on a global ocean, is rather thin, and has a strongly non-uniform thickness. Tidal effects are enhanced by crustal thinning at the south pole, so that realistic models of tidal tectonics and dissipation should take into account the lateral variations of shell structure. I construct here the theory of non-uniform viscoelastic thin shells, allowing for depth-dependent rheology and large lateral variations of shell thickness and rheology. Coupling to tides yields two 2D linear partial differential equations of the fourth order on the sphere which take into account self-gravity, density stratification below the shell, and core viscoelasticity. If the shell is laterally uniform, the solution agrees with analytical formulas for tidal Love numbers; errors on displacements and stresses are less than 5% and 15%, respectively, if the thickness is less than 10% of the radius. If the shell is non-uniform, the tidal thin shell equations are solved as a system of coupled linear equations in a spherical harmonic basis. Compared to finite element models, thin shell predictions are similar for the deformations due to Enceladus's pressurized ocean, but differ for the tides of Ganymede. If Enceladus's shell is conductive with isostatic thickness variations, surface stresses are approximately inversely proportional to the local shell thickness. The radial tide is only moderately enhanced at the south pole. The combination of crustal thinning and convection below the poles can amplify south polar stresses by a factor of 10, but it cannot explain the apparent time lag between the maximum plume brightness and the opening of tiger stripes. In a second paper, I will study the impact of a non-uniform crust on tidal dissipation.

  13. Non-uniform Pressure Distribution in Draw-Bend Friction Test and its Influence on Friction Measurement

    International Nuclear Information System (INIS)

    Kim, Young Suk; Jain, Mukesh K.; Metzger, Don R.

    2005-01-01

    From various draw-bend friction tests with sheet metals at lubricated conditions, it has been unanimously reported that the friction coefficient increases as the pin diameter decreases. However, a proper explanation for this phenomenon has not been given yet. In those experiments, tests were performed for different pin diameters while keeping the same average contact pressure by adjusting applied tension forces. In this paper, pressure profiles at pin/strip contacts and the changes in the pressure profiles depending on pin diameters are investigated using finite element simulations. To study the effect of the pressure profile changes on friction measurements, a non-constant friction model (Stribeck friction model), which is more realistic for the lubricated sheet metal contacts, is implemented into the finite element code and applied to the simulations. The study shows that the non-uniformity of the pressure profile increases and the pin/strip contact angle decreases as the pin diameter decreases, and these phenomena increase the friction coefficient, which is calculated from the strip tension forces using a conventional rope-pulley equation

  14. Distribution pattern assessment of a dual-purpose disc agrochemical applicator for field crops

    Directory of Open Access Journals (Sweden)

    M. S. Abubakar

    2012-08-01

    Full Text Available A dual-purpose disc agrochemical applicator for field crops was developed to boost agricultural mechanization in crop production and also to overcome the safety concern of hazardous spray drift during agrochemical application by the field crop farmers. The dual purpose agrochemical applicator was mounted on a high clearance tractor and tested with respect to the granular fertilizer distribution patterns uniformity/liquid chemical uniformity of droplet sizes in spraying of the agrochemical. Results for NPK granular chemical indicated that, at low (50 kg/ha and high (150 kg/ha application rates with 550 rpm disc speed, distribution patterns skewed to the left whereas the distribution pattern at medium (100 kg/ha application rates was good flattop. Also at high application rate with 1000 rpm disc speed, mean distribution pattern became poor (W-shape. For the liquid chemical herbicide HC 48 amine liquid, the mean values of volume median diameter (VMD and number median diameter (NMD were 108 µm and 80 µm at 90 lt/ha application rate at 5000 rpm rotary disc speed, and also 344 and 222 µm at 30 lt/ha application rate with 2000 rpm rotary disc speed. The mean values of coefficient of uniformity for droplet sizes expressed as VMD/NMD found in this study were in the range of 1.35 to 1.55 for HC amine 48 liquid chemical.

  15. A CFD Study on Inlet Plenum Flow Field of Pebble Bed Reactor

    International Nuclear Information System (INIS)

    Kim, Min Hwan; Lee, Won Jae; Chang, Jong Hwa

    2005-01-01

    High temperature gas cooled reactor, largely divided into two types of PBR (Pebble Bed Reactor) and PMR (Prismatic Modular Reactor), has becomes great interest of researchers in connection with the hydrogen production. KAERI has started a project to develop the gas cooled reactor for the hydrogen production and has been doing in-depth study for selecting the reactor type between PBR and PMR. As a part of the study, PBMR (Pebble Bed Modular Reactor) was selected as a reference PBR reactor for the CFD analysis and the flow field of its inlet plenum was simulated with computational fluid dynamics program CFX5. Due to asymmetrical arrangement of pipes to the inlet plenum, non-uniform flow distribution has been expected to occur, giving rise to non-uniform power distribution at the core. Flow fields of different arrangement of inlet pipes were also investigated, as one of measures to reduce the non-uniformity

  16. Model calculation of the scanned field enhancement factor of CNTs

    International Nuclear Information System (INIS)

    Ahmad, Amir; Tripathi, V K

    2006-01-01

    The field enhancement factor of a carbon nanotube (CNT) placed in a cluster of CNTs is smaller than an isolated CNT because the electric field on one tube is screened by neighbouring tubes. This screening depends on the length of the CNTs and the spacing between them. We have derived an expression to compute the field enhancement factor of CNTs under any positional distribution of CNTs using a model of a floating sphere between parallel anode and cathode plates. Using this expression we can compute the field enhancement factor of a CNT in a cluster (non-uniformly distributed CNTs). This expression is used to compute the field enhancement factor of a CNT in an array (uniformly distributed CNTs). Comparison has been shown with experimental results and existing models

  17. Experimental Investigation of Temperature Distribution along the Length of Uniform Area Fin for Forced and Free Convection

    Science.gov (United States)

    Kannojiya, Vikas; Sharma, Riya; Gaur, Rahul; Jangra, Anil; Yadav, Pushpender; Prajapati, Pooja

    2018-03-01

    The overheating of an industrial component sometimes may leads to system failure. The convection heat transfer from a heated surface can be effectively enhanced by employing fins on that surface. This Paper emphasizes on the experimental investigation of temperature distribution along the length of pin shaped fin. The analysis is performed on a 100 mm long fin made up of brass with 19.6 mm diameter having thermal conductivity as 111 W/m.K. Temperature at different section of the fin along its length is evaluated experimentally and theoretically. The influence of convection mode viz natural & forced convection and variable heat input on the temperature distribution is evaluated. The result outcomes are then compared with the widely accepted analytical relations. A comparison of convective heat transfer coefficient for uniform and non-uniform area fin is also presented. The results by experimental and analytical method are found to be in good agreement for free convection phenomenon.

  18. Exact analytic expressions for the evolution of polarization for radiation propagating in a plasma with non uniformly sheared magnetic field

    International Nuclear Information System (INIS)

    Segre, S. E.

    2001-01-01

    The known analytic expressions for the evolution of the polarization of electromagnetic waves propagating in a plasma with uniformly sheared magnetic field are extended to the case where the shear is not constant. Exact analytic expressions are found for the case when the space variations of the medium are such that the magnetic field components and the plasma density satisfy a particular condition (eq. 13), possibly in a convenient reference frame of polarization space [it

  19. A novel scene-based non-uniformity correction method for SWIR push-broom hyperspectral sensors

    Science.gov (United States)

    Hu, Bin-Lin; Hao, Shi-Jing; Sun, De-Xin; Liu, Yin-Nian

    2017-09-01

    A novel scene-based non-uniformity correction (NUC) method for short-wavelength infrared (SWIR) push-broom hyperspectral sensors is proposed and evaluated. This method relies on the assumption that for each band there will be ground objects with similar reflectance to form uniform regions when a sufficient number of scanning lines are acquired. The uniform regions are extracted automatically through a sorting algorithm, and are used to compute the corresponding NUC coefficients. SWIR hyperspectral data from airborne experiment are used to verify and evaluate the proposed method, and results show that stripes in the scenes have been well corrected without any significant information loss, and the non-uniformity is less than 0.5%. In addition, the proposed method is compared to two other regular methods, and they are evaluated based on their adaptability to the various scenes, non-uniformity, roughness and spectral fidelity. It turns out that the proposed method shows strong adaptability, high accuracy and efficiency.

  20. Large eddy simulation of a buoyancy-aided flow in a non-uniform channel – Buoyancy effects on large flow structures

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Y. [Department of Mechanical Engineering, University of Sheffield, Sheffield S1 3JD (United Kingdom); School of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester M13 9PL (United Kingdom); He, S., E-mail: s.he@sheffield.ac.uk [Department of Mechanical Engineering, University of Sheffield, Sheffield S1 3JD (United Kingdom)

    2017-02-15

    Highlights: • Buoyancy may greatly redistribute the flow in a non-uniform channel. • Flow structures in the narrow gap are greatly changed when buoyancy is strong. • Large flow structures exist in wider gap, which is enhanced when heat is strong. • Buoyancy reduces mixing factor caused by large flow structures in narrow gap. - Abstract: It has been a long time since the ‘abnormal’ turbulent intensity distribution and high inter-sub-channel mixing rates were observed in the vicinity of the narrow gaps formed by the fuel rods in nuclear reactors. The extraordinary flow behaviour was first described as periodic flow structures by Hooper and Rehme (1984). Since then, the existences of large flow structures were demonstrated by many researchers in various non-uniform flow channels. It has been proved by many authors that the Strouhal number of the flow structure in the isothermal flow is dependent on the size of the narrow gap, not the Reynolds number once it is sufficiently large. This paper reports a numerical investigation on the effect of buoyancy on the large flow structures. A buoyancy-aided flow in a tightly-packed rod-bundle-like channel is modelled using large eddy simulation (LES) together with the Boussinesq approximation. The behaviour of the large flow structures in the gaps of the flow passage are studied using instantaneous flow fields, spectrum analysis and correlation analysis. It is found that the non-uniform buoyancy force in the cross section of the flow channel may greatly redistribute the velocity field once the overall buoyancy force is sufficiently strong, and consequently modify the large flow structures. The temporal and axial spatial scales of the large flow structures are influenced by buoyancy in a way similar to that turbulence is influenced. These scales reduce when the flow is laminarised, but start increasing in the turbulence regeneration region. The spanwise scale of the flow structures in the narrow gap remains more or

  1. Magnetohydrodynamic flow in a rectangular duct under a uniform transverse magnetic field at high Hartmann number

    International Nuclear Information System (INIS)

    Temperley, D.J.

    1976-01-01

    In this paper we consider fully developed, laminar, unidirectional flow of uniformly conducting, incompressible fluid through a rectangular duct of uniform cross-section. An externally applied magnetic field acts parallel to one pair of opposite walls and induced velocity and magnetic fields are generated in a direction parallel to the axis of the duct. The governing equations and boundary conditions for the latter fields are introduced and study is then concentrated on the special case of a duct having all walls non-conducting. For values of the Hartmann number M>>1, classical asymptotic analysis reveals the leading terms in the expansions of the induced fields in all key regions, with the exception of certain boundary layers near the corners of the duct. The order of magnitude of the affect of the latter layers on the flow-rate is discussed and closed-form solutions are obtained for the induced fields near the corners of the duct. Attempts were made to formulate a concise Principle of Minimum Singularity to enable the correct choice of eigen functions for the various field components in the boundary layers on the walls parallel to the applied field. It was found, however, that these components are best found by taking the outer expansion of the closed-form solution in those boundary-layers near the corners of the duct where classical asymptotic analysis is not applicable. (author)

  2. Field distribution analysis in deflecting structures

    Energy Technology Data Exchange (ETDEWEB)

    Paramonov, V.V. [Joint Inst. for Nuclear Research, Moscow (Russian Federation)

    2013-02-15

    Deflecting structures are used now manly for bunch rotation in emittance exchange concepts, bunch diagnostics and to increase the luminosity. The bunch rotation is a transformation of a particles distribution in the six dimensional phase space. Together with the expected transformations, deflecting structures introduce distortions due to particularities - aberrations - in the deflecting field distribution. The distributions of deflecting fields are considered with respect to non linear additions, which provide emittance deteriorations during a transformation. The deflecting field is treated as combination of hybrid waves HE{sub 1} and HM{sub 1}. The criteria for selection and formation of deflecting structures with minimized level of aberrations are formulated and applied to known structures. Results of the study are confirmed by comparison with results of numerical simulations.

  3. Field distribution analysis in deflecting structures

    International Nuclear Information System (INIS)

    Paramonov, V.V.

    2013-02-01

    Deflecting structures are used now manly for bunch rotation in emittance exchange concepts, bunch diagnostics and to increase the luminosity. The bunch rotation is a transformation of a particles distribution in the six dimensional phase space. Together with the expected transformations, deflecting structures introduce distortions due to particularities - aberrations - in the deflecting field distribution. The distributions of deflecting fields are considered with respect to non linear additions, which provide emittance deteriorations during a transformation. The deflecting field is treated as combination of hybrid waves HE 1 and HM 1 . The criteria for selection and formation of deflecting structures with minimized level of aberrations are formulated and applied to known structures. Results of the study are confirmed by comparison with results of numerical simulations.

  4. A charged black hole in a uniform magnetic field

    International Nuclear Information System (INIS)

    Krori, K.D.; Chaudhury, S.; Dowerah, S.

    1983-01-01

    We present here an investigation of the event horizon of a charged black hole embedded in a uniform magnetic field studying the Gaussian curvature. It is shown that the Gauss-Bonnet theorem holds for this magnetized black hole and for a magnetized Kerr black hole

  5. Radiation effects on the mixed convection flow induced by an inclined stretching cylinder with non-uniform heat source/sink.

    Science.gov (United States)

    Hayat, Tasawar; Qayyum, Sajid; Alsaedi, Ahmed; Asghar, Saleem

    2017-01-01

    This study investigates the mixed convection flow of Jeffrey liquid by an impermeable inclined stretching cylinder. Thermal radiation and non-uniform heat source/sink are considered. The convective boundary conditions at surface are imposed. Nonlinear expressions of momentum, energy and concentration are transformed into dimensionless systems. Convergent homotopic solutions of the governing systems are worked out by employing homotopic procedure. Impact of physical variables on the velocity, temperature and concentration distributions are sketched and discussed. Numerical computations for skin friction coefficient, local Nusselt and Sherwood numbers are carried out. It is concluded that velocity field enhances for Deborah number while reverse situation is observed regarding ratio of relaxation to retardation times. Temperature and heat transfer rate are enhanced via larger thermal Biot number. Effect of Schmidt number on the concentration and local Sherwood number is quite reverse.

  6. Analysis of Quantum Effects in Non-Uniformly Doped MOS Structures

    National Research Council Canada - National Science Library

    Fiegna, Claudio

    1997-01-01

    This paper presents results from the self-consistent solution of Schrodinger and Poisson equations obtained in one-dimensional non-uniformly doped MOS structures suitable for the fabrication of very short transistors...

  7. Uniform and non-uniform inlet temperature of a vertical hot water jet injected into a rectangular tank

    KAUST Repository

    El-Amin, Mohamed; Sun, Shuyu

    2010-01-01

    In most of real-world applications, such as the case of heat stores, inlet is not kept at a constant temperature but it may vary with time during charging process. In this paper, a vertical water jet injected into a rectangular storage tank is measured experimentally and simulated numerically. Two cases of study are considered; one is a hot water jet with uniform inlet temperature (UIT) injected into a cold water tank, and the other is a cold water jet with non-uniform inlet temperature (NUIT) injected into a hot water tank. Three different temperature differences and three different flow rates are studied for the hot water jet with UIT which is injected into a cold water tank. Also, three different initial temperatures with constant flow rate as well as three different flow rates with constant initial temperature are considered for the cold jet with NUIT which is injected into a hot water tank. Turbulence intensity at the inlet as well as Reynolds number for the NUIT cases are therefore functions of inlet temperature and time. Both experimental measurements and numerical calculations are carried out for the same measured flow and thermal conditions. The realizable k-ε model is used for modeling the turbulent flow. Numerical solutions are obtained for unsteady flow while pressure, velocity, temperature and turbulence distributions inside the water tank are analyzed. The simulated results are compared to the measured results, and they show a good agreement at low temperatures. © 2010 IEEE.

  8. Uniform and non-uniform inlet temperature of a vertical hot water jet injected into a rectangular tank

    KAUST Repository

    El-Amin, Mohamed

    2010-12-01

    In most of real-world applications, such as the case of heat stores, inlet is not kept at a constant temperature but it may vary with time during charging process. In this paper, a vertical water jet injected into a rectangular storage tank is measured experimentally and simulated numerically. Two cases of study are considered; one is a hot water jet with uniform inlet temperature (UIT) injected into a cold water tank, and the other is a cold water jet with non-uniform inlet temperature (NUIT) injected into a hot water tank. Three different temperature differences and three different flow rates are studied for the hot water jet with UIT which is injected into a cold water tank. Also, three different initial temperatures with constant flow rate as well as three different flow rates with constant initial temperature are considered for the cold jet with NUIT which is injected into a hot water tank. Turbulence intensity at the inlet as well as Reynolds number for the NUIT cases are therefore functions of inlet temperature and time. Both experimental measurements and numerical calculations are carried out for the same measured flow and thermal conditions. The realizable k-ε model is used for modeling the turbulent flow. Numerical solutions are obtained for unsteady flow while pressure, velocity, temperature and turbulence distributions inside the water tank are analyzed. The simulated results are compared to the measured results, and they show a good agreement at low temperatures. © 2010 IEEE.

  9. Exploration of a possible cause of magnetic reconfiguration/reconnection due to generation, rather than annihilation, of magnetic field in a nun-uniform thin current sheet

    Science.gov (United States)

    Huang, Y. C.; Lyu, L. H.

    2014-12-01

    Magnetic reconfiguration/reconnection plays an important role on energy and plasma transport in the space plasma. It is known that magnetic field lines on two sides of a tangential discontinuity can connect to each other only at a neutral point, where the strength of the magnetic field is equal to zero. Thus, the standard reconnection picture with magnetic field lines intersecting at the neutral point is not applicable to the component reconnection events observed at the magnetopause and in the solar corona. In our early study (Yu, Lyu, & Wu, 2011), we have shown that annihilation of magnetic field near a thin current sheet can lead to the formation of normal magnetic field component (normal to the current sheet) to break the frozen-in condition and to accelerate the reconnected plasma flux, even without the presence of a neutral point. In this study, we examine whether or not a generation, rather than annihilation, of magnetic field in a nun-uniform thin current sheet can also lead to reconnection of plasma flux. Our results indicate that a non-uniform enhancement of electric current can yield formation of field-aligned currents. The normal-component magnetic field generated by the field-aligned currents can yield reconnection of plasma flux just outside the current-enhancement region. The particle motion that can lead to non-uniform enhancement of electric currents will be discussed.

  10. Development of distributed ion pumps for g-2 beam vacuum system

    Energy Technology Data Exchange (ETDEWEB)

    Hseuh, H.C.; Mapes, M.; Snydstrup, L.

    1993-06-01

    Distributed ion pumps (DIPs) will be used for the beam vacuum system of the g-2 muon storage ring. The magnetic field intensity and alignment angle at the DIP locations are not uniform. The pumping behavior of several different ion pump elements under this non-uniform magnetic field has been studied. The results are compared with the theoretical predictions. Based on these results, the optimum design of the g-2 DIPs has been developed.

  11. Development of distributed ion pumps for g-2 beam vacuum system

    Energy Technology Data Exchange (ETDEWEB)

    Hseuh, H.C.; Mapes, M.; Snydstrup, L.

    1993-01-01

    Distributed ion pumps (DIPs) will be used for the beam vacuum system of the g-2 muon storage ring. The magnetic field intensity and alignment angle at the DIP locations are not uniform. The pumping behavior of several different ion pump elements under this non-uniform magnetic field has been studied. The results are compared with the theoretical predictions. Based on these results, the optimum design of the g-2 DIPs has been developed.

  12. Optimization of Pockels electric field in transverse modulated optical voltage sensor

    Science.gov (United States)

    Huang, Yifan; Xu, Qifeng; Chen, Kun-Long; Zhou, Jie

    2018-05-01

    This paper investigates the possibilities of optimizing the Pockels electric field in a transverse modulated optical voltage sensor with a spherical electrode structure. The simulations show that due to the edge effect and the electric field concentrations and distortions, the electric field distributions in the crystal are non-uniform. In this case, a tiny variation in the light path leads to an integral error of more than 0.5%. Moreover, a 2D model cannot effectively represent the edge effect, so a 3D model is employed to optimize the electric field distributions. Furthermore, a new method to attach a quartz crystal to the electro-optic crystal along the electric field direction is proposed to improve the non-uniformity of the electric field. The integral error is reduced therefore from 0.5% to 0.015% and less. The proposed method is simple, practical and effective, and it has been validated by numerical simulations and experimental tests.

  13. Ballistic charge carrier transmission through graphene multi-barrier structures in uniform magnetic field

    International Nuclear Information System (INIS)

    Zubarev, A; Dragoman, D

    2014-01-01

    We investigate charge carrier transport in graphene multi-barrier structures placed in a uniform magnetic field. The transmission coefficient is found analytically by generalizing the transfer matrix method for the case of graphene regions subjected to a uniform magnetic field. The transmission coefficient through the structure can be modulated by varying the gate voltages, the magnetic field and/or the width of the gated regions. Such a configuration could be used in multiple-valued logic circuits, since it has several output states with discrete and easily selectable transmission/current values. (paper)

  14. Uniform distribution of TiCp in TiCp/Zn-Al composites prepared by XDTM

    Institute of Scientific and Technical Information of China (English)

    王香; 马旭梁; 李庆芬; 曾松岩

    2002-01-01

    The prefabricated Al/TiC alloy with high TiC particle content was prepared by XDTM process. The uniform distribution process of TiC particles in the stationary zinc melt was studied and analyzed using self-made experimental equipment, and the model of the uniform distribution process was built. The results show that zinc diffuses into the prepared Al/TiC alloy after it is placed in the zinc melt at temperatures below the melting point of aluminum, which leads to the decrease of the liquidus temperature of Al-Zn alloy in the surface layer of Al/TiC alloy. When the liquidus temperature of Al-Zn alloy is equal to or below the temperature of zinc melt, Al-Zn alloy melts and TiC particles drop with it from the Al/TiC alloy and then transfer into the zinc melt and finally distribute uniformly in it.

  15. Some Analytical Properties of the Model for Stochastic Evolutionary Games in Finite Populations with Non-uniform Interaction Rate

    International Nuclear Information System (INIS)

    Quan Ji; Wang Xianjia

    2013-01-01

    Traditional evolutionary games assume uniform interaction rate, which means that the rate at which individuals meet and interact is independent of their strategies. But in some systems, especially biological systems, the players interact with each other discriminately. Taylor and Nowak (2006) were the first to establish the corresponding non-uniform interaction rate model by allowing the interaction rates to depend on strategies. Their model is based on replicator dynamics which assumes an infinite size population. But in reality, the number of individuals in the population is always finite, and there will be some random interference in the individuals' strategy selection process. Therefore, it is more practical to establish the corresponding stochastic evolutionary model in finite populations. In fact, the analysis of evolutionary games in a finite size population is more difficult. Just as Taylor and Nowak said in the outlook section of their paper, ''The analysis of non-uniform interaction rates should be extended to stochastic game dynamics of finite populations''. In this paper, we are exactly doing this work. We extend Taylor and Nowak's model from infinite to finite case, especially focusing on the infiuence of non-uniform connection characteristics on the evolutionary stable state of the system. We model the strategy evolutionary process of the population by a continuous ergodic Markov process. Based on the limit distribution of the process, we can give the evolutionary stable state of the system. We make a complete classification of the symmetric 2 × 2 games. For each case game, the corresponding limit distribution of the Markov-based process is given when noise intensity is small enough. In contrast with most literatures in evolutionary games using the simulation method, all our results obtained are analytical. Especially, in the dominant-case game, coexistence of the two strategies may become evolutionary stable states in our model. This result can be

  16. Low-frequency electrostatic dust-modes in a non-uniform

    Indian Academy of Sciences (India)

    A self-consistent and general description of obliquely propagating low-frequency electrostatic dust-modes in a non-uniform magnetized dusty plasma system has been presented. A number of different situations, which correspond to different low-frequency electrostatic dust-modes, namely, dust-acoustic mode, dust-drift ...

  17. Design of a high field uniformity electromagnet for Penning trap

    International Nuclear Information System (INIS)

    Itteera, Janvin; Singh, Kumud; Teotia, Vikas; Ukarde, Priti; Malhotra, Sanjay; Taly, Y.K.; Joshi, Manoj; Rao, Pushpa

    2013-01-01

    An ion trap (Penning trap) facility is being developed at BARC for spectroscopy studies. This requires the design of an iron core electromagnet capable of generating high magnetic fields (∼1.7T) at the centre of an 88 mm long air gap. This electromagnet provides the requisite dipole magnetic field which when superimposed on the electrostatic quadrupoles ensures a stable trapping of ions. To conduct high precision spectroscopy studies, we need to ensure a high degree of magnetic field uniformity ( 3 volume (Trap zone). Various pole shoe profiles were studied and modelled, FEM simulation of the same were conducted to compute the magnetic field intensity and field uniformity. Owing to the large air gap and requirement of high field intensity in the GFR, the exciting coils need to handle high current densities, which require water cooled systems. Double Pan-Cake coil design is selected for powering the magnet. Electrical, thermal and hydraulic designs of the coils are completed and a prototype double pancake coil was fabricated and tested for verifying the electrical and thermal parameter. The spatial field homogeneity is achieved by shimming the pole tip. Temporal stability of magnet requires a highly stable power supply for exciting the coils and its stability class is derived from FEM simulations. This paper discusses the electromagnetic design and development of the penning trap magnet being developed at BARC. (author)

  18. Non-uniform cosine modulated filter banks using meta-heuristic algorithms in CSD space

    Directory of Open Access Journals (Sweden)

    Shaeen Kalathil

    2015-11-01

    Full Text Available This paper presents an efficient design of non-uniform cosine modulated filter banks (CMFB using canonic signed digit (CSD coefficients. CMFB has got an easy and efficient design approach. Non-uniform decomposition can be easily obtained by merging the appropriate filters of a uniform filter bank. Only the prototype filter needs to be designed and optimized. In this paper, the prototype filter is designed using window method, weighted Chebyshev approximation and weighted constrained least square approximation. The coefficients are quantized into CSD, using a look-up-table. The finite precision CSD rounding, deteriorates the filter bank performances. The performances of the filter bank are improved using suitably modified meta-heuristic algorithms. The different meta-heuristic algorithms which are modified and used in this paper are Artificial Bee Colony algorithm, Gravitational Search algorithm, Harmony Search algorithm and Genetic algorithm and they result in filter banks with less implementation complexity, power consumption and area requirements when compared with those of the conventional continuous coefficient non-uniform CMFB.

  19. Effects of non-uniformities on electrical conduction in weakly ionized plasmas

    International Nuclear Information System (INIS)

    Numano, M.; Murakami, Y.; Nitta, T.

    1989-01-01

    The effect of non-uniformities on the flow of electric current in weakly ionized plasmas is investigated by taking into account the ion slip as well as the Hall current. An Ohm's law for a non-uniform plasma is derived, from which the formula previously obtained by Numano, i.e. an extension of Rosa's equation, is obtainable as a special case. Making use of this new Ohm's law, the effective electrical conductivity and the effective Hall parameter are determined for isotropically turbulent plasmas. It is found that when the ion-slip effect is absent they are in good agreement with the results obtained previously. (author)

  20. One-way Ponderomotive Barrier in a Uniform Magnetic Field

    International Nuclear Information System (INIS)

    Dodin, I.Y.; Fisch, N.J.

    2005-01-01

    The possibility of an asymmetric ponderomotive barrier in a nonuniform dc magnetic field by high-frequency radiation near the cyclotron resonance for selected plasma species was contemplated in Physics of Plasmas 11 (November 2004) 5046-5064. Here we show that a similar one-way barrier, which reflects particles incident from one side while transmitting those incident from the opposite side, can be produced also in a uniform magnetic field, entirely due to inhomogeneity of high-frequency drive

  1. Control of field uniformity for a large superconducting storage ring magnet

    International Nuclear Information System (INIS)

    Danby, G.T.; Jackson, J.W.

    1994-01-01

    A 1.45 Tesla, 14.2 meter diameter ''superferric'' magnet is in an advanced stage of construction at BNL. This magnet will be used to store muons for a planned ultra-precise measurement of their anomalous magnetic moment g-2. This measurement requires a magnetic field uniformity of 1 PPM with a knowledge of the field over the muon orbits to 0.1 PPM. The methods built into the design to produce ultra-high field uniformity will be described. Large deviations from the ideal circularly symmetric uniform shape of the iron flux path are required to accommodate transfer lines and superconducting current leads, as well as apparatus for beam injection. Shimming methods to correct for the perturbations due to these large holes will be presented. The pole pieces consist of 36 closely fitting 10 degree arc sections butted together to produce a very good approximation to a continuous 360 degree ring magnet. However, in the cast of a possible quench of the superconducting coils, significant eddy currents will be induced which will circulate within the confines of each 10 degree pole piece. At the great precision required, these eddy currents may leave very small but significant aberrations in the field even after they decay away, because of slight changes in the orientation of the magnetization. Surface coil possibilities to correct for this effect will be described

  2. Effects of uniform extracellular DC electric fields on excitability in rat hippocampal slices in vitro.

    Science.gov (United States)

    Bikson, Marom; Inoue, Masashi; Akiyama, Hiroki; Deans, Jackie K; Fox, John E; Miyakawa, Hiroyoshi; Jefferys, John G R

    2004-05-15

    The effects of uniform steady state (DC) extracellular electric fields on neuronal excitability were characterized in rat hippocampal slices using field, intracellular and voltage-sensitive dye recordings. Small electric fields (tips of basal and apical dendrites. The polarization was biphasic in the mid-apical dendrites; there was a time-dependent shift in the polarity reversal site. DC fields altered the thresholds of action potentials evoked by orthodromic stimulation, and shifted their initiation site along the apical dendrites. Large electric fields could trigger neuronal firing and epileptiform activity, and induce long-term (>1 s) changes in neuronal excitability. Electric fields perpendicular to the apical-dendritic axis did not induce somatic polarization, but did modulate orthodromic responses, indicating an effect on afferents. These results demonstrate that DC fields can modulate neuronal excitability in a time-dependent manner, with no clear threshold, as a result of interactions between neuronal compartments, the non-linear properties of the cell membrane, and effects on afferents.

  3. Non-uniform velocity profile mechanism for flame stabilization in a porous radiant burner

    Energy Technology Data Exchange (ETDEWEB)

    Catapan, R.C.; Costa, M. [Mechanical Engineering Department, Instituto Superior Tecnico, Technical University of Lisbon, Avenida Rovisco Pais, 1049-001 Lisbon (Portugal); Oliveira, A.A.M. [Mechanical Engineering Department, Federal University of Santa Catarina, Campus Universitario Professor Joao David Ferreira Lima, 88040-900 Florianopolis, SC (Brazil)

    2011-01-15

    Industrial processes where the heating of large surfaces is required lead to the possibility of using large surface porous radiant burners. This causes additional temperature uniformity problems, since it is increasingly difficult to evenly distribute the reactant mixture over a large burner surface while retaining its stability and keeping low pollutant emissions. In order to allow for larger surface area burners, a non-uniform velocity profile mechanism for flame stabilization in a porous radiant burner using a single large injection hole is proposed and analyzed for a double-layered burner operating in open and closed hot (laboratory-scale furnace, with temperature-controlled, isothermal walls) environments. In both environments, local mean temperatures within the porous medium have been measured. For lower reactant flow rate and ambient temperature the flame shape is conical and anchored at the rim of the injection hole. As the volumetric flow rate or furnace temperature is raised, the flame undergoes a transition to a plane flame stabilized near the external burner surface. However, the stability range envelope remains the same in both regimes. (author)

  4. The effect of non-uniform temperature and velocity fields on long range ultrasonic measurement systems in MYRRHA

    Energy Technology Data Exchange (ETDEWEB)

    Van de Wyer, Nicolas; Schram, Christophe [von Karman Institute For Fluids Dynamic (Belgium); Van Dyck, Dries; Dierckx, Marc [Belgian Nuclear Research Center (Belgium)

    2015-07-01

    SCK.CEN, the Belgian Nuclear Research Center, is developing MYRRHA, a generation IV liquid metal cooled nuclear research reactor. As the liquid metal coolant is opaque to light, normal visual feedback during fuel manipulations is not available and must therefore be replaced by a system that is not hindered by the opacity of the coolant. In this respect ultrasonic based instrumentation is under development at SCK.CEN to provide feedback during operations under liquid metal. One of the tasks that will be tackled using ultrasound is the detection and localization of a potentially lost fuel assembly. In this application, the distance between ultrasonic sensor and target may be as large as 2.5 m. At these distances, non uniform velocity and temperature fields in the liquid metal potentially influence the propagation of the ultrasonic signals, affecting the performance of the ultrasonic systems. In this paper, we investigate how relevant temperature and velocity gradients inside the liquid metal influence the propagation of ultrasonic waves. The effect of temperature and velocity gradients are simulated by means of a newly developed numerical ray-tracing model. The performance of the model is validated by dedicated water experiments. The setup is capable of creating velocity and temperature gradients representative for MYRRHA conditions. Once validated in water, the same model is used to make predictions for the effect of gradients in the MYRRHA liquid metal environment. (authors)

  5. Pose control of the chain composed of magnetic particles using external uniform and gradient magnetic fields

    International Nuclear Information System (INIS)

    Zhou, J. F.; Shao, C. L.; Gu, B. Q.

    2016-01-01

    Magnetic particles (MPs) are known to respond to a magnetic field and can be moved by magnetic force, which make them good carriers in bioengineering and pharmaceutical engineering. In this paper, a pose control method for the straight chain composed of MPs is proposed, and the chain with one pose can be moved to another position with another pose using alternately employed uniform and gradient magnetic fields. Based on computer simulations, it is revealed that in the uniform magnetic field, the MPs form a straight chain with the same separation space along the field lines, and once the uniform magnetic field rotates, the chain also rotates with the field. In the gradient magnetic field, the MPs move toward the higher field so that the translation of the chain can be realized. The simulation results indicate that while the uniform magnetic field is rotating, there exists certain hysteresis between the chain and the field, and the chain is not straight anymore. So the uniform magnetic field should rest at the target angle for a period to make the chain fully relax to be straight. For nanoMP, its magnetic moment directly determines the gradient magnetic force which is much smaller than the dipole–dipole force among MPs. Therefore, the translation of the chain is much more time-consuming than rotation. To enlarge the translational velocity, it is suggested to increase the size of MPs or the magnetic field gradient

  6. Effects of transient and non-uniform distribution of heat flux on intensity of heat transfer and burnout conditions in the channels of nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Vitaly Osmachkin [Russian Research Center ' Kurchatov Institute' 1, Kurchatov sq, Moscow 123182 (Russian Federation)

    2005-07-01

    Full text of publication follows: The influence of power transient, changes of flow rate, inlet temperatures or pressure in cores of nuclear reactors on heat transfer and burnout conditions in channels depend on rate of such violations. Non-uniform distribution of the heat flux is also important factor for heat transfer and development of crisis phenomenon. Such effects may be significant for NPPs safety. But they have not yet generally accepted interpretation. Steady state approach is often recommended for use in calculations. In the paper a review of experimental observed so-called non-equilibrium effects is presented. The effects of space and time factors are displaying due delay in reformation turbulence intensity, velocity, temperatures or void fraction profiles, water film flow on the surface of heated channels. For estimation of such effect different methods are used. Modern computer codes based on two or three fluids approaches are considered as most effective. But simple and clear correlations may light up the mechanics of effects on heat transfer and improve general understanding of scale and significance of the transient events. In the paper the simplified methods for assessment the influence of lags in the development of distributions of parameters of flow, the relaxation of temporal or space violations are considered. They are compared with more sophisticated approaches. Velocities of disturbance fronts moving along the channels are discussed also. (author)

  7. Magnetic fields and uniformity of radio frequency power deposition in low-frequency inductively coupled plasmas with crossed internal oscillating currents

    International Nuclear Information System (INIS)

    Tsakadze, E.L.; Ostrikov, K.; Tsakadze, Z.L.; Vladimirov, S.V.; Xu, S.

    2004-01-01

    Radial and axial distributions of magnetic fields in a low-frequency (∼460 kHz) inductively coupled plasma source with two internal crossed planar rf current sheets are reported. The internal antenna configuration comprises two orthogonal sets of eight alternately reconnected parallel and equidistant copper litz wires in quartz enclosures and generates three magnetic (H z , H r , and H φ ) and two electric (E φ and E r ) field components at the fundamental frequency. The measurements have been performed in rarefied and dense plasmas generated in the electrostatic (E) and electromagnetic (H) discharge modes using two miniature magnetic probes. It is shown that the radial uniformity and depth of the rf power deposition can be improved as compared with conventional sources of inductively coupled plasmas with external flat spiral ('pancake') antennas. Relatively deeper rf power deposition in the plasma source results in more uniform profiles of the optical emission intensity, which indicates on the improvement of the plasma uniformity over large chamber volumes. The results of the numerical modeling of the radial magnetic field profiles are found in a reasonable agreement with the experimental data

  8. High density, uniformly distributed W/UO2 for use in Nuclear Thermal Propulsion

    Science.gov (United States)

    Tucker, Dennis S.; Barnes, Marvin W.; Hone, Lance; Cook, Steven

    2017-04-01

    An inexpensive, quick method has been developed to obtain uniform distributions of UO2 particles in a tungsten matrix utilizing 0.5 wt percent low density polyethylene. Powders were sintered in a Spark Plasma Sintering (SPS) furnace at 1600 °C, 1700 °C, 1750 °C, 1800 °C and 1850 °C using a modified sintering profile. This resulted in a uniform distribution of UO2 particles in a tungsten matrix with high densities, reaching 99.46% of theoretical for the sample sintered at 1850 °C. The powder process is described and the results of this study are given below.

  9. Research on Creep Relaxation Non-uniformity and Effect on Performance of Combined Rotor

    Science.gov (United States)

    Liu, Qingya; He, Jingfei; Zhao, Lijia

    2017-11-01

    The combined rotor of gas turbine is connected by a certain number of rod bolts. It works in the high temperature environment for a long time, and the rod bolts will creep and relax. Under the influence of elastic interaction, the loss of pretightening force of rod bolts at different positions is non-uniform, which will cause the connection of the combined rotor to be out of tune. In this paper, the creep relaxation non-uniformity model for a class F heavy duty gas turbine is established. On the basis of this, the performance degradation and structural strength change of combined rotor resulting from creep relaxation non-uniformity of rod bolts are studied. The results show that the ratio of preload mistuning increases with time and then converges, and there is a threshold inflection point in about seven thousand hours.

  10. Dynamic rheological properties of viscoelastic magnetic fluids in uniform magnetic fields

    International Nuclear Information System (INIS)

    Yamaguchi, Hiroshi; Niu Xiaodong; Ye Xiaojiang; Li Mingjun; Iwamoto, Yuhiro

    2012-01-01

    The dynamic rheological properties of viscoelastic magnetic fluids in externally applied uniform magnetic fields are investigated by a laboratory-made cone-plate rheometer in this study. In particular, the effects of the magnetic field on the viscoelastic properties (the complex dynamic modulus) of the viscoelastic magnetic fluids are studied. In the investigation, three viscoelastic magnetic fluids are made by mixing a magnetic fluid and a viscoelastic fluid with different mass ratios. As a supplementation to the experimental investigation, a theoretical analysis is also presented. The present study shows that the viscosity and elasticity of the viscoelastic magnetic fluids are significantly influenced by the magnetic field and the concentrations of the magnetic particles in the test fluids. Theoretical analysis qualitatively explains the present findings. - Highlights: ► The dynamic rheological properties of the viscoelastic magnetic fluids in uniform magnetic fields are investigated. ► Both the magnetic field strength and the concentration of the magnetic particles in the fluids have significant effects on the viscosity and elasticity of the viscoelastic magnetic fluids. ► Theoretical prediction and analysis qualitatively explains the present findings.

  11. Electron energy distribution function control in gas discharge plasmas

    International Nuclear Information System (INIS)

    Godyak, V. A.

    2013-01-01

    The formation of the electron energy distribution function (EEDF) and electron temperature in low temperature gas discharge plasmas is analyzed in frames of local and non-local electron kinetics. It is shown, that contrary to the local case, typical for plasma in uniform electric field, there is the possibility for EEDF modification, at the condition of non-local electron kinetics in strongly non-uniform electric fields. Such conditions “naturally” occur in some self-organized steady state dc and rf discharge plasmas, and they suggest the variety of artificial methods for EEDF modification. EEDF modification and electron temperature control in non-equilibrium conditions occurring naturally and those stimulated by different kinds of plasma disturbances are illustrated with numerous experiments. The necessary conditions for EEDF modification in gas discharge plasmas are formulated

  12. Examining the departure in response of non-point detectors due to non-uniform illumination and displacement of effective center

    International Nuclear Information System (INIS)

    Khabaz, Rahim

    2013-01-01

    A mathematical simulation approach based on the general purpose Monte Carlo N-particle transport code MCNP was developed to calculate the departure in reading of the neutron spectrometer instrument from that expected according to the inverse square law. The calculations were performed to evaluate the effects of beam divergence on the response of a 10 in. spherical device equipped with a long BF 3 counter irradiated by 11 mono-energy neutron beams. The necessary geometry correction factor, because of non-uniform illumination, for the calibration of seven polyethylene spheres with several radionuclide neutron sources, i.e. Ra–Be, 241 Am–Be, 241 Am–B and Po–Be sources was also determined. In all calculations, the displacement of effective center from the geometric center of moderating spheres, when used as an instrument for neutron fluence measurement, was quantified. -- Highlights: • The commonly applied method for measuring the energy spectrum of neutron fields is BSS. • One of the problems of the BSS is the geometry correction factor. • This factor is related to the non-uniform illumination of the spectrometer. • At short distances, serious departure was created in reading from the inverse square law. • This study evaluates a Monte Carlo method to calculate this factor and related parameters

  13. Examining the departure in response of non-point detectors due to non-uniform illumination and displacement of effective center

    Energy Technology Data Exchange (ETDEWEB)

    Khabaz, Rahim, E-mail: r.khabaz@gu.ac.ir

    2013-11-11

    A mathematical simulation approach based on the general purpose Monte Carlo N-particle transport code MCNP was developed to calculate the departure in reading of the neutron spectrometer instrument from that expected according to the inverse square law. The calculations were performed to evaluate the effects of beam divergence on the response of a 10 in. spherical device equipped with a long BF{sub 3} counter irradiated by 11 mono-energy neutron beams. The necessary geometry correction factor, because of non-uniform illumination, for the calibration of seven polyethylene spheres with several radionuclide neutron sources, i.e. Ra–Be, {sup 241}Am–Be, {sup 241}Am–B and Po–Be sources was also determined. In all calculations, the displacement of effective center from the geometric center of moderating spheres, when used as an instrument for neutron fluence measurement, was quantified. -- Highlights: • The commonly applied method for measuring the energy spectrum of neutron fields is BSS. • One of the problems of the BSS is the geometry correction factor. • This factor is related to the non-uniform illumination of the spectrometer. • At short distances, serious departure was created in reading from the inverse square law. • This study evaluates a Monte Carlo method to calculate this factor and related parameters.

  14. Issues in measure-preserving three dimensional flow integrators: Self-adjointness, reversibility, and non-uniform time stepping

    International Nuclear Information System (INIS)

    Finn, John M.

    2015-01-01

    Properties of integration schemes for solenoidal fields in three dimensions are studied, with a focus on integrating magnetic field lines in a plasma using adaptive time stepping. It is shown that implicit midpoint (IM) and a scheme we call three-dimensional leapfrog (LF) can do a good job (in the sense of preserving KAM tori) of integrating fields that are reversible, or (for LF) have a “special divergence-free” (SDF) property. We review the notion of a self-adjoint scheme, showing that such schemes are at least second order accurate and can always be formed by composing an arbitrary scheme with its adjoint. We also review the concept of reversibility, showing that a reversible but not exactly volume-preserving scheme can lead to a fractal invariant measure in a chaotic region, although this property may not often be observable. We also show numerical results indicating that the IM and LF schemes can fail to preserve KAM tori when the reversibility property (and the SDF property for LF) of the field is broken. We discuss extensions to measure preserving flows, the integration of magnetic field lines in a plasma and the integration of rays for several plasma waves. The main new result of this paper relates to non-uniform time stepping for volume-preserving flows. We investigate two potential schemes, both based on the general method of Feng and Shang [Numer. Math. 71, 451 (1995)], in which the flow is integrated in split time steps, each Hamiltonian in two dimensions. The first scheme is an extension of the method of extended phase space, a well-proven method of symplectic integration with non-uniform time steps. This method is found not to work, and an explanation is given. The second method investigated is a method based on transformation to canonical variables for the two split-step Hamiltonian systems. This method, which is related to the method of non-canonical generating functions of Richardson and Finn [Plasma Phys. Controlled Fusion 54, 014004 (2012

  15. An Investigation into Conversion from Non-Uniform Rational B-Spline Boundary Representation Geometry to Constructive Solid Geometry

    Science.gov (United States)

    2015-12-01

    ARL-SR-0347 ● DEC 2015 US Army Research Laboratory An Investigation into Conversion from Non-Uniform Rational B-Spline Boundary...US Army Research Laboratory An Investigation into Conversion from Non-Uniform Rational B-Spline Boundary Representation Geometry to...from Non-Uniform Rational B-Spline Boundary Representation Geometry to Constructive Solid Geometry 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c

  16. Human thermal sensation and comfort in a non-uniform environment with personalized heating.

    Science.gov (United States)

    Deng, Qihong; Wang, Runhuai; Li, Yuguo; Miao, Yufeng; Zhao, Jinping

    2017-02-01

    Thermal comfort in traditionally uniform environment is apparent and can be improved by increasing energy expenses. To save energy, non-uniform environment implemented by personalized conditioning system attracts considerable attention, but human response in such environment is unclear. To investigate regional- and whole-body thermal sensation and comfort in a cool environment with personalized heating. In total 36 subjects (17 males and 19 females) including children, adults and the elderly, were involved in our experiment. Each subject was first asked to sit on a seat in an 18°C chamber (uniform environment) for 40min and then sit on a heating seat in a 16°C chamber (non-uniform environment) for another 40min after 10min break. Subjects' regional- and whole-body thermal sensation and comfort were surveyed by questionnaire and their skin temperatures were measured by wireless sensors. We statistically analyzed subjects' thermal sensation and comfort and their skin temperatures in different age and gender groups and compared them between the uniform and non-uniform environments. Overall thermal sensation and comfort votes were respectively neutral and just comfortable in 16°C chamber with personalized heating, which were significantly higher than those in 18°C chamber without heating (pthermal sensation and comfort was consistent in subjects of different age and gender. However, adults and the females were more sensitive to the effect of personalized heating and felt cooler and less comfort than children/elderly and the males respectively. Variations of the regional thermal sensation/comfort across human body were consistent with those of skin temperature. Personalized heating significantly improved human thermal sensation and comfort in non-uniform cooler environment, probably due to the fact that it increased skin temperature. However, the link between thermal sensation/comfort and variations of skin temperature is rather complex and warrant further

  17. Temperature distribution in a uniformly moving medium

    International Nuclear Information System (INIS)

    Mitchell, Joseph D; Petrov, Nikola P

    2009-01-01

    We apply several physical ideas to determine the steady temperature distribution in a medium moving with uniform velocity between two infinite parallel plates. We compute it in the coordinate frame moving with the medium by integration over the 'past' to account for the influence of an infinite set of instantaneous point sources of heat in past moments as seen by an observer moving with the medium. The boundary heat flux is simulated by appropriately distributed point heat sources on the inner side of an adiabatically insulating boundary. We make an extensive use of the Green functions with an emphasis on their physical meaning. The methodology used in this paper is of great pedagogical value as it offers an opportunity for students to see the connection between powerful mathematical techniques and their physical interpretation in an intuitively clear physical problem. We suggest several problems and a challenging project that can be easily incorporated in undergraduate or graduate courses

  18. Dynamic behaviour of non-uniform Bernoulli-Euler beams subjected ...

    African Journals Online (AJOL)

    This paper investigates the dynamics behaviour of non-uniform Bernoulli-Euler beams subjected to concentrated loads ravelling at variable velocities. The solution technique is based on the Generalized Galerkin Method and the use of the generating function of the Bessel function type. The results show that, for all the ...

  19. Advanced GF(32) nonbinary LDPC coded modulation with non-uniform 9-QAM outperforming star 8-QAM.

    Science.gov (United States)

    Liu, Tao; Lin, Changyu; Djordjevic, Ivan B

    2016-06-27

    In this paper, we first describe a 9-symbol non-uniform signaling scheme based on Huffman code, in which different symbols are transmitted with different probabilities. By using the Huffman procedure, prefix code is designed to approach the optimal performance. Then, we introduce an algorithm to determine the optimal signal constellation sets for our proposed non-uniform scheme with the criterion of maximizing constellation figure of merit (CFM). The proposed nonuniform polarization multiplexed signaling 9-QAM scheme has the same spectral efficiency as the conventional 8-QAM. Additionally, we propose a specially designed GF(32) nonbinary quasi-cyclic LDPC code for the coded modulation system based on the 9-QAM non-uniform scheme. Further, we study the efficiency of our proposed non-uniform 9-QAM, combined with nonbinary LDPC coding, and demonstrate by Monte Carlo simulation that the proposed GF(23) nonbinary LDPC coded 9-QAM scheme outperforms nonbinary LDPC coded uniform 8-QAM by at least 0.8dB.

  20. Impact of roof height non-uniformity on pollutant transport between a street canyon and intersections.

    Science.gov (United States)

    Nosek, Štěpán; Kukačka, Libor; Jurčáková, Klára; Kellnerová, Radka; Jaňour, Zbyněk

    2017-08-01

    This paper presents an extension of our previous wind-tunnel study (Nosek et al., 2016) in which we highlighted the need for investigation of the removal mechanisms of traffic pollution from all openings of a 3D street canyon. The extension represents the pollution flux (turbulent and advective) measurements at the lateral openings of three different 3D street canyons for the winds perpendicular and oblique to the along-canyon axis. The pollution was simulated by emitting a passive gas (ethane) from a homogeneous ground-level line source positioned along the centreline of the investigated street canyons. The street canyons were formed by courtyard-type buildings of two different regular urban-array models. The first model has a uniform building roof height, while the second model has a non-uniform roof height along each building's wall. The mean flow and concentration fields at the canyons' lateral openings confirm the findings of other studies that the buildings' roof-height variability at the intersections plays an important role in the dispersion of the traffic pollutants within the canyons. For the perpendicular wind, the non-uniform roof-height canyon appreciably removes or entrains the pollutant through its lateral openings, contrary to the uniform canyon, where the pollutant was removed primarily through the top. The analysis of the turbulent mass transport revealed that the coherent flow structures of the lateral momentum transport correlate with the ventilation processes at the lateral openings of all studied canyons. These flow structures coincide at the same areas and hence simultaneously transport the pollutant in opposite directions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. A numerical model to evaluate the flow distribution in a large solar collector field

    DEFF Research Database (Denmark)

    Bava, Federico; Dragsted, Janne; Furbo, Simon

    2017-01-01

    This study presents a numerical model to evaluate the flow distribution in a large solar collector field, with solar collectors connected both in series and in parallel. The boundary conditions of the systems, such as flow rate, temperature, fluid type and layout of the collector field can...... be easily changed in the model. The model was developed in Matlab and the calculated pressure drop and flow distribution were compared with measurements from a solar collector field. A good agreement between model and measurements was found. The model was then used to study the flow distribution...... in different conditions. Balancing valves proved to be an effective way to achieve uniform flow distribution also in conditions different from those for which the valves were regulated. For small solar collector fields with limited number of collector rows connected in parallel, balancing valves...

  2. Response of a uniform optical fiber Bragg grating to strain with a non-smooth distribution: measurements and simulations

    Science.gov (United States)

    Detka, Małgorzata

    2017-08-01

    The paper presents results of numerical analyses of the response of a uniform fiber Bragg grating subjected to a strain with non-smooth profile. Results of measurements of the response of the grating to a compressive strain correspond well with results of the simulation and show, that the induced strain profile of the grating causes a widening of its reflection spectrum with a considerable shape irregularity, dependent on the location of the point where slope of the strain profile changes abruptly, and on the maximum value of the strain.

  3. The influence of cathode excavation of cathodic arc evaporator on thickness uniformity and erosion products angle distribution

    Directory of Open Access Journals (Sweden)

    D. V. Duhopel'nikov

    2014-01-01

    Full Text Available Cathodic arc evaporators are used for coating with functional films. Prolonged or buttend evaporators may be used for this purposes. In butt-end evaporator the cathode spots move continuously on the cathode work surface and evaporate cathode material. High depth excavation profile forms on the cathode work surface while the thick coating precipitation (tens or hundreds of microns. The cathode excavation profile is shaped like a “cup” with high walls for electrostatic discharge stabilization systems with axial magnetic fields. Cathode spots move on the bottom of the “cup”. It is very likely that high “cup” walls are formed as a result of lasting work time influence on the uniformity of precipitated films.In the present work the influence of excavation profile walls height on the uniformity of precipitated coating was carried out. The high profile walls are formed due to lasting work of DC vacuum arc evaporator. The cathode material used for tests was 3003 aluminum alloy. The extended substrate was placed parallel to the cathode work surface. Thickness distribution along the substrate length with the new cathode was obtained after 6 hours and after 12 hours of continuous operation.The thickness distribution of precipitated coating showed that the cathode excavation has an influence on the angular distribution of the matter escaping the cathode. It can be clearly seen from the normalized dependence coating thickness vs the distance from the substrate center. Also the angular distribution of the matter flow from the cathode depending on the cathode working time was obtained. It was shown that matter flow from the cathode differs from the LambertKnudsen law. The more the cathode excavation the more this difference.So, cathode excavation profile has an influence on the uniformity of precipitated coating and it is necessary to take in account the cathode excavation profile while coating the thick films.

  4. Five-dimensional rotating black hole in a uniform magnetic field: The gyromagnetic ratio

    International Nuclear Information System (INIS)

    Aliev, A.N.; Frolov, Valeri P.

    2004-01-01

    In four-dimensional general relativity, the fact that a Killing vector in a vacuum spacetime serves as a vector potential for a test Maxwell field provides one with an elegant way of describing the behavior of electromagnetic fields near a rotating Kerr black hole immersed in a uniform magnetic field. We use a similar approach to examine the case of a five-dimensional rotating black hole placed in a uniform magnetic field of configuration with biazimuthal symmetry that is aligned with the angular momenta of the Myers-Perry spacetime. Assuming that the black hole may also possess a small electric charge we construct the five-vector potential of the electromagnetic field in the Myers-Perry metric using its three commuting Killing vector fields. We show that, like its four-dimensional counterparts, the five-dimensional Myers-Perry black hole rotating in a uniform magnetic field produces an inductive potential difference between the event horizon and an infinitely distant surface. This potential difference is determined by a superposition of two independent Coulomb fields consistent with the two angular momenta of the black hole and two nonvanishing components of the magnetic field. We also show that a weakly charged rotating black hole in five dimensions possesses two independent magnetic dipole moments specified in terms of its electric charge, mass, and angular momentum parameters. We prove that a five-dimensional weakly charged Myers-Perry black hole must have the value of the gyromagnetic ratio g=3

  5. A segmented cell approach for studying the effects of serpentine flow field parameters on PEMFC current distribution

    International Nuclear Information System (INIS)

    Reshetenko, Tatyana V.; Bender, Guido; Bethune, Keith; Rocheleau, Richard

    2013-01-01

    Highlights: ► Effects of a flow field design on PEMFC were investigated. ► A segmented cell was used to study 6- and 10-channel serpentine flow fields. ► 10-Channel flow field improved a fuel cell's performance at high current. ► Performance distribution was more uniform for 10-channel than for 6-channel flow field. ► The performance improvement was due to an increased pressure drop. -- Abstract: A serpentine flow field is a commonly used design in proton exchange membrane fuel cells (PEMFCs). Consequently, optimization of the flow field parameters is critically needed. A segmented cell system was used to study the impact of the flow field's parameters on the current distribution in a PEMFC, and the data obtained were analyzed in terms of voltage overpotentials. 6-Channel and 10-channel serpentine flow field designs were investigated. At low current the segments performance was found to slightly decrease for a 10-channel serpentine flow field. However, increasing the number of channels increased the fuel cell performance when operating at high current and the cell performance became more uniform downstream. The observed improvement in fuel cell performance was attributed to a decrease in mass transfer voltage losses (permeability and diffusion), due to an increased pressure drop. Spatially distributed electrochemical impedance spectroscopy (EIS) data showed differences in the local segment impedance response and confirmed the performance distribution and the impact of the flow field design

  6. Numerical Study of the Inertia Effect on Flow Distribution in Micro-gap Plate Heat Exchanger

    International Nuclear Information System (INIS)

    Park, Jang Min; Yoon, Seok Ho; Lee, Kong Hoon; Song Chan Ho

    2014-01-01

    This paper presents numerical study on flow and heat transfer characteristics in micro-gap plate heat exchanger. In particular, we investigate the effect of flow inertia on the flow distribution from single main channel to multiple parallel micro-gaps. The flow regime of the main channel is varied from laminar regime (Reynolds number of 100) to turbulent regime (Reynolds number of 10000) by changing the flow rate, and non-uniformity of the flow distribution and temperature field is evaluated quantitatively based on the standard deviation. The flow distribution is found to be significantly affected by not only the header design but also the flow rate of the main channel. It is also observed that the non-uniformity of the temperature field has its maximum at the intermediate flow regime

  7. Gravitational Influences on Flame Propagation through Non-Uniform, Premixed Gas Systems

    Science.gov (United States)

    Miller, Fletcher J.; Easton, John; Ross, Howard D.; Marchese, Anthony; Perry, David; Kulis, Michael

    2001-01-01

    Flame propagation through non-uniformly premixed (or layered) gases has importance both in useful combustion systems and in unintentional fires. As summarized previously, non-uniform premixed gas combustion receives scant attention compared to the more usual limiting cases of diffusion or uniformly premixed flames, especially regarding the role gravity plays. This paper summarizes our progress on furthering the knowledge of layered combustion, in which a fuel concentration gradient exists normal to the direction of flame spread. We present experimental and numerical results for flame spread through propanol-air layers formed near the flash point temperature (25 C) or near the stoichiometric temperature (33 C). Both the model and experimental results show that the removal of gravity results in a faster spreading flame, by as much as 80% depending on conditions. This is exactly the opposite effect as that predicted by an earlier model reported. We also found that having a gallery lid results in faster flame spread, an effect more pronounced at normal gravity, demonstrating the importance of enclosure geometry. Also reported here is the beginning of our spectroscopic measurements of fuel vapor.

  8. Determination of non-uniformity correction factors for cylindrical ionization chambers close to 192Ir brachytherapy sources

    International Nuclear Information System (INIS)

    Toelli, H.; Bielajew, A. F.; Mattsson, O.; Sernbo, G.

    1995-01-01

    When ionization chambers are used in brachytherapy dosimetry, the measurements must be corrected for the non-uniformity of the incident photon fluence. The theory for determination of non-uniformity correction factors, developed by Kondo and Randolph (Rad. Res. 1960) assumes that the electron fluence within the air cavity is isotropic and does not take into account material differences in the chamber wall. The theory was extended by Bielajew (PMB 1990) using an anisotropic electron angular fluence in the cavity. In contrast to the theory by Kondo and Randolph, the anisotropic theory predicts a wall material dependence in the non-uniformity correction factors. This work presents experimental determination of non-uniformity correction factors at distances between 10 and 140 mm from an Ir-192 source. The experimental work makes use of a PTW23331-chamber and Farmer-type chambers (NE2571 and NE2581) with different materials in the walls. The results of the experiments agree well with the anisotropic theory. Due to the geometrical shape of the NE-type chambers, it is shown that the full length of the these chambers, 24.1mm, is not an appropriate input parameter when theoretical non-uniformity correction factors are evaluated

  9. Effects of non-uniform embedments on earthquake responses of nuclear reactor building

    International Nuclear Information System (INIS)

    Koyanagi, Y.; Okamoto, S.; Yoshida, K.; Inove, H.

    1989-01-01

    The nuclear reactor buildings have the portion embedded in soil. In the seismic design of such structures, it is essential to consider the effects of the embedment on the earthquake response. Most studies on these effects, however, assume the uniform embedment, i.e. the depth of the embedment is constant, which is convenient for the design and analysis. The behavior of the earthquake response considering the three-dimensional aspects of non-uniform embedment has not been made clear yet. In this paper, the authors evaluate the effects of the non-uniform embedment in an inclined ground surface on the earthquake response of a nuclear reactor building as illustrated. A typical PWR type reactor building is chosen as an analysis structure model. Four different types of embedment are set up for the comparison study. The three-dimensional analysis is carried out considering the geometry of embedment

  10. Vlasov-Maxwell equilibrium solutions for Harris sheet magnetic field with Kappa velocity distribution

    International Nuclear Information System (INIS)

    Fu, W.-Z.; Hau, L.-N.

    2005-01-01

    An exact solution of the steady-state, one-dimensional Vlasov-Maxwell equations for a plasma current sheet with oppositely directed magnetic field was found by Harris in 1962. The so-called Harris magnetic field model assumes Maxwellian velocity distributions for oppositely drifting ions and electrons and has been widely used for plasma stability studies. This paper extends Harris solutions by using more general κ distribution functions that incorporate Maxwellian distribution in the limit of κ→∞. A new functional form for the plasma pressure as a function of the magnetic vector potential p(A) is found and the magnetic field is a modified tanh z function. In the extended solutions the effective temperature is no longer spatially uniform like in the Harris model and the thickness of the current layer decreases with decreasing κ

  11. Reply to comment on 'Model calculation of the scanned field enhancement factor of CNTs'

    International Nuclear Information System (INIS)

    Ahmad, Amir; Tripathi, V K

    2010-01-01

    In the paper (Ahmad and Tripathi 2006 Nanotechnology 17 3798), we derived an expression to compute the field enhancement factor of CNTs under any positional distribution of CNTs by using the model of a floating sphere between parallel anode and cathode plates. Using this expression we can compute the field enhancement factor of a CNT in a cluster (non-uniformly distributed CNTs). This expression was used to compute the field enhancement factor of a CNT in an array (uniformly distributed CNTs). We used an approximation to calculate the field enhancement factor. Hence, our expressions are correct in that assumption only. Zhbanov et al (2010 Nanotechnology 21 358001) suggest a correction that can calculate the field enhancement factor without using the approximation. Hence, this correction can improve the applicability of this model. (reply)

  12. An efficient shutter-less non-uniformity correction method for infrared focal plane arrays

    Science.gov (United States)

    Huang, Xiyan; Sui, Xiubao; Zhao, Yao

    2017-02-01

    The non-uniformity response in infrared focal plane array (IRFPA) detectors has a bad effect on images with fixed pattern noise. At present, it is common to use shutter to prevent from radiation of target and to update the parameters of non-uniformity correction in the infrared imaging system. The use of shutter causes "freezing" image. And inevitably, there exists the problems of the instability and reliability of system, power consumption, and concealment of infrared detection. In this paper, we present an efficient shutter-less non-uniformity correction (NUC) method for infrared focal plane arrays. The infrared imaging system can use the data gaining in thermostat to calculate the incident infrared radiation by shell real-timely. And the primary output of detector except the shell radiation can be corrected by the gain coefficient. This method has been tested in real infrared imaging system, reaching high correction level, reducing fixed pattern noise, adapting wide temperature range.

  13. Non-uniformity of phase structure in immiscible polymer blends

    Czech Academy of Sciences Publication Activity Database

    Fortelný, Ivan; Lapčíková, Monika; Lednický, František; Starý, Zdeněk; Kruliš, Zdeněk

    2008-01-01

    Roč. 48, č. 3 (2008), s. 564-571 ISSN 0032-3888 R&D Projects: GA ČR GA106/06/0729; GA ČR GA106/06/0761 Institutional research plan: CEZ:AV0Z40500505 Keywords : polymer blends * melt mixing * non-uniform morphology Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.245, year: 2008

  14. Effect of a uniform magnetic induction field upon the flow of an electrically conducting fluid placed in a straight rectangular cross section, one of the walls of which, characterized by an infinite conductivity, presents uniform translation movement

    International Nuclear Information System (INIS)

    Herve, Patrick

    1975-01-01

    This is a theoretical study of an electrically viscous fluid flowing in a straight rectangular cross section channel, a wall of which, infinitely conducting, is placed perpendicularly to the direction of a uniform magnetic induction field. The three other walls of the channel being electrically insulating, remain motionless. Formulas giving velocity distribution law in the straight section of the flow in relation to the Hartmann's number, curves illustrating the accelerating effect produced across the whole section, by the application of the magnetic induction field, and example for the distribution of the electric current lines in case of a square section are given [fr

  15. Deep convolutional neural networks for dense non-uniform motion deblurring

    CSIR Research Space (South Africa)

    Cronje, J

    2015-11-01

    Full Text Available to form a dense non-uniform motion estimation map. Furthermore, a second CNN is trained to perform deblurring given a blurry image patch and the estimated motion vector. Combining the two trained networks result in a deep learning approach that can enhance...

  16. Comparisons of uniform and discrete source distributions for use in bioassay laboratory performance testing

    International Nuclear Information System (INIS)

    Scherpelz, R.I.; MacLellan, J.A.

    1987-09-01

    The Pacific Northwest Laboratory (PNL) is sending a torso phantom with radioactive material uniformly distributed in the lungs to in vivo bioassay laboratories for analysis. Although the radionuclides ultimately chosen for the studies had relatively long half-lives, future accreditation testing will require repeated tests with short half-life test nuclides. Computer modeling was used to simulate the major components of the phantom. Radiation transport calculations were then performed using the computer models to calculate dose rates either 15 cm from the chest or at its surface. For 144 Ce and 60 Co, three configurations were used for the lung comparison tests. Calculations show that, for most detector positions, a single plug containing 40 K located in the back of the heart provides a good approximation to a uniform distribution of 40 K. The approximation would lead, however, to a positive bias for the detector reading if the detector were located at the chest surface near the center. Loading the 40 K in a uniform layer inside the chest wall is not a good approximation of the uniform distribution in the lungs, because most of the radionuclides would be situated close to the detector location and the only shielding would be the thickness of the chest wall. The calculated dose rates for 60 Co and 144 Ce were similar at all calculated reference points. 3 refs., 5 figs., 10 tabs

  17. The electric field of a uniformly charged cubic shell

    Science.gov (United States)

    McCreery, Kaitlin; Greenside, Henry

    2018-01-01

    As an integrative and insightful example for undergraduates learning about electrostatics, we discuss how to use symmetry, Coulomb's law, superposition, Gauss's law, and visualization to understand the electric field E (x ,y ,z ) produced by a uniformly charged cubic shell. We first discuss how to deduce qualitatively, using freshman-level physics, the perhaps surprising fact that the interior electric field is nonzero and has a complex structure, pointing inwards from the middle of each face of the shell and pointing outwards towards each edge and corner. We then discuss how to understand the quantitative features of the electric field by plotting an analytical expression for E along symmetry lines and on symmetry surfaces of the shell.

  18. Selective exfoliation of single-layer graphene from non-uniform graphene grown on Cu

    International Nuclear Information System (INIS)

    Lim, Jae-Young; Lee, Jae-Hyun; Jang, Hyeon-Sik; Whang, Dongmok; Joo, Won-Jae; Hwang, SungWoo

    2015-01-01

    Graphene growth on a copper surface via metal-catalyzed chemical vapor deposition has several advantages in terms of providing high-quality graphene with the potential for scale-up, but the product is usually inhomogeneous due to the inability to control the graphene layer growth. The non-uniform regions strongly affect the reliability of the graphene in practical electronic applications. Herein, we report a novel graphene transfer method that allows for the selective exfoliation of single-layer graphene from non-uniform graphene grown on a Cu foil. Differences in the interlayer bonding energy are exploited to mechanically separate only the top single-layer graphene and transfer this to an arbitrary substrate. The dry-transferred single-layer graphene showed electrical characteristics that were more uniform than those of graphene transferred using conventional wet-etching transfer steps. (paper)

  19. An Improved Rate-Transient Analysis Model of Multi-Fractured Horizontal Wells with Non-Uniform Hydraulic Fracture Properties

    Directory of Open Access Journals (Sweden)

    Youwei He

    2018-02-01

    Full Text Available Although technical advances in hydraulically fracturing and drilling enable commercial production from tight reservoirs, oil/gas recovery remains at a low level. Due to the technical and economic limitations of well-testing operations in tight reservoirs, rate-transient analysis (RTA has become a more attractive option. However, current RTA models hardly consider the effect of the non-uniform production on rate decline behaviors. In fact, PLT results demonstrate that production profile is non-uniform. To fill this gap, this paper presents an improved RTA model of multi-fractured horizontal wells (MFHWs to investigate the effects of non-uniform properties of hydraulic fractures (production of fractures, fracture half-length, number of fractures, fracture conductivity, and vertical permeability on rate transient behaviors through the diagnostic type curves. Results indicate obvious differences on the rate decline curves among the type curves of uniform properties of fractures (UPF and non-uniform properties of fractures (NPF. The use of dimensionless production integral derivative curve magnifies the differences so that we can diagnose the phenomenon of non-uniform production. Therefore, it’s significant to incorporate the effects of NPF into the RDA models of MFHWs, and the model proposed in this paper enables us to better evaluate well performance based on long-term production data.

  20. Uniform distribution and quasi-Monte Carlo methods discrepancy, integration and applications

    CERN Document Server

    Kritzer, Peter; Pillichshammer, Friedrich; Winterhof, Arne

    2014-01-01

    The survey articles in this book focus on number theoretic point constructions, uniform distribution theory, and quasi-Monte Carlo methods. As deterministic versions of the Monte Carlo method, quasi-Monte Carlo rules enjoy increasing popularity, with many fruitful applications in mathematical practice, as for example in finance, computer graphics, and biology.

  1. Dose distribution of IMRT and 3D-CRT on treating central non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Zhu Xiaoyang; Yu Guangwei

    2010-01-01

    3D-CRT and IMRT were used in the radiation therapy of Central Non-small-cell lung cancer (NSCLC), and the dose difference of the methods was estimated. Thirty-two patients suffering with II class NSCLC were selected. Based on CT images, each patient was given 1 3D-CRT (3 dimensional conformal radiotherapy) and 2 IMRT(intensity modulated radiation therapy) treatment plans (5 fields and 7 fields), respectively, and the dose distribution was evaluated too. The results showed that PTVD mean and the PTV max , PTVD max (%) and CI of IMRT were both higher than those of 3D-CRT, but the uniformity was not as good as 3D-CRT. All indexes of lung and spinal cord treated with IMRT were lower than that treated with 3D-CRT. Moreover, there was no significance of the difference between 5 fields and 7 fields. In a conclusion, IMRT could not only decrease the target dose of NSCLC, but it can protect normal tissue from radiation damage effectively. And when IMRT was used, 5 fields might be enough. (authors)

  2. Hydra phantom applicability for carrying out tests of field uniformity in gamma cameras

    International Nuclear Information System (INIS)

    Aragao Filho, Geraldo L.; Oliveira, Alex C.H.

    2014-01-01

    Nuclear Medicine is a medical modality that makes use of radioactive material 'in vivo' in humans, making them a temporary radioactive source. The radiation emitted by the patient's body is detected by a specific equipment, called a gamma camera, creates an image showing the spatial and temporal biodistribution of radioactive material administered to the patient. Therefore, it's of fundamental importance a number of specific measures to make sure that procedure be satisfactory, called quality control. To Nuclear Medicine, quality control of gamma camera has the purpose of ensuring accurate scintillographic imaging, truthful and reliable for the diagnosis, guaranteeing visibility and clarity of details of structures, and also to determine the frequency and the need for preventive maintenance of equipment. To ensure the quality control of the gamma camera it's necessary to use some simulators, called phantom, used in Nuclear Medicine to evaluate system performance, system calibration and simulation of injuries. The goal of this study was to validate a new simulator for nuclear medicine, the Hydra phantom. The phantom was initially built for construction of calibration curves used in radiotherapy planning and quality control in CT. It has similar characteristics to specific phantoms in nuclear medicine, containing inserts and water area. Those inserts are regionally sourced materials, many of them are already used in the literature and based on information about density and interaction of radiation with matter. To verify its efficiency in quality control in Nuclear Medicine, was performed a test for uniformity field, one of the main tests performed daily, so we can verify the ability of the gamma camera to reproduce a uniform distribution of the administered activity in the phantom, been analysed qualitatively, through the image, and quantitatively, through values established for Central Field Of View (CFOV) and Useful Field Of View (UFOV). Also, was evaluated their

  3. Self-adaptive change detection in streaming data with non-stationary distribution

    KAUST Repository

    Zhang, Xiangliang; Wang, Wei

    2010-01-01

    Non-stationary distribution, in which the data distribution evolves over time, is a common issue in many application fields, e.g., intrusion detection and grid computing. Detecting the changes in massive streaming data with a non

  4. Temperature dependence of o-Ps annihilation lifetime in non-uniform cylindrical pores in comparison with ETE model

    Energy Technology Data Exchange (ETDEWEB)

    Khaghani, Morteza, E-mail: m.khaghani@pgs.usb.ac.ir; Mehmandoost-Khajeh-Dad, Ali Akbar, E-mail: mehmandoost@phys.usb.ac.ir

    2017-04-01

    Highlights: • Using the well known multi-physics program COMSOL calculating o-Ps annihilation lifetime in complex geometries. • Investigation of shape non-uniformity of cylindrical pores on o-Ps annihilation lifetime. • Verifying temperature dependency of o-Ps lifetime in non-uniform cylindrical pores. • Suggesting PALS at low temperature as a method to verify pore uniformity in porous material. - Abstract: Ortho-positronium (o-Ps) annihilation lifetime was calculated in non-uniform cylinder-shaped pores by solving Schrodinger equation using a well-known multi-physics program called COMSOL. The o-Ps annihilation lifetime variation in terms of temperature was calculated on the basis of ETE model via a numerical method. The COMSOL simulations indicate that as long as the pore is uniform cylinder-shaped, the results agree with those of two-dimensional ETE model, whereas deformations in the cylinder shape (indentation or protrusion) change the temperature behavior of ETE model and, thereby, higher values are predicted for o-Ps lifetime in the pore at lower temperatures. The geometry of the non-uniform cylinder-shaped pores, which is accompanied by empirical evidence, can be used for the analysis of empirical results obtained from positron lifetime spectroscopy in different temperatures.

  5. Lateral diffusion of the topological charge density in stochastic optical fields

    CSIR Research Space (South Africa)

    Roux, FS

    2010-01-01

    Full Text Available Stochastic (i.e. random and quasi-random) optical fields may contain distributions of optical vortices that are represented by non-uniform topological charge densities. Numerical simulations are used to investigate the evolution under free...

  6. Dynamic Uniform Scaling for Multiobjective Genetic Algorithms

    DEFF Research Database (Denmark)

    Pedersen, Gerulf; Goldberg, David E.

    2004-01-01

    Before Multiobjective Evolutionary Algorithms (MOEAs) can be used as a widespread tool for solving arbitrary real world problems there are some salient issues which require further investigation. One of these issues is how a uniform distribution of solutions along the Pareto non-dominated front c...

  7. Dynamic Uniform Scaling for Multiobjective Genetic Algorithms

    DEFF Research Database (Denmark)

    Pedersen, Gerulf; Goldberg, D.E.

    2004-01-01

    Before Multiobjective Evolutionary Algorithms (MOEAs) can be used as a widespread tool for solving arbitrary real world problems there are some salient issues which require further investigation. One of these issues is how a uniform distribution of solutions along the Pareto non-dominated front can...

  8. Nonimaging polygonal mirrors achieving uniform irradiance distributions on concentrating photovoltaic cells.

    Science.gov (United States)

    Schmitz, Max; Dähler, Fabian; Elvinger, François; Pedretti, Andrea; Steinfeld, Aldo

    2017-04-10

    We introduce a design methodology for nonimaging, single-reflection mirrors with polygonal inlet apertures that generate a uniform irradiance distribution on a polygonal outlet aperture, enabling a multitude of applications within the domain of concentrated photovoltaics. Notably, we present single-mirror concentrators of square and hexagonal perimeter that achieve very high irradiance uniformity on a square receiver at concentrations ranging from 100 to 1000 suns. These optical designs can be assembled in compound concentrators with maximized active area fraction by leveraging tessellation. More advanced multi-mirror concentrators, where each mirror individually illuminates the whole area of the receiver, allow for improved performance while permitting greater flexibility for the concentrator shape and robustness against partial shading of the inlet aperture.

  9. A thick-walled sphere rotating in a uniform magnetic field: The next step to de-spin a space object

    Science.gov (United States)

    Nurge, Mark A.; Youngquist, Robert C.; Caracciolo, Ryan A.; Peck, Mason; Leve, Frederick A.

    2017-08-01

    Modeling the interaction between a moving conductor and a static magnetic field is critical to understanding the operation of induction motors, eddy current braking, and the dynamics of satellites moving through Earth's magnetic field. Here, we develop the case of a thick-walled sphere rotating in a uniform magnetic field, which is the simplest, non-trivial, magneto-statics problem that leads to complete closed-form expressions for the resulting potentials, fields, and currents. This solution requires knowledge of all of Maxwell's time independent equations, scalar and vector potential equations, and the Lorentz force law. The paper presents four cases and their associated experimental results, making this topic appropriate for an advanced student lab project.

  10. Diffuse sound field: challenges and misconceptions

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2016-01-01

    Diffuse sound field is a popular, yet widely misused concept. Although its definition is relatively well established, acousticians use this term for different meanings. The diffuse sound field is defined by a uniform sound pressure distribution (spatial diffusion or homogeneity) and uniform...... tremendously in different chambers because the chambers are non-diffuse in variously different ways. Therefore, good objective measures that can quantify the degree of diffusion and potentially indicate how to fix such problems in reverberation chambers are needed. Acousticians often blend the concept...... of mixing and diffuse sound field. Acousticians often refer diffuse reflections from surfaces to diffuseness in rooms, and vice versa. Subjective aspects of diffuseness have not been much investigated. Finally, ways to realize a diffuse sound field in a finite space are discussed....

  11. New non-orthogonality treatment for atmospheric boundary layer flow simulation above highly non-uniform terrains

    Directory of Open Access Journals (Sweden)

    Mirkov Nikola S.

    2016-01-01

    Full Text Available In this paper we validate an improved finite volume approximation of Reynolds Averaged Navier-Stokes equations for simulation of wind flows in body-fitted grids generated by algebraic extrusion from digital terrain elevation data, proposed in N. Mirkov et. al. J. Comput. Phys. 287, 18-45(2015, [1]. The approach is based on second-order accurate finite volume method with collocated variable arrangement and pressure-velocity coupling trough SIMPLE algorithm. The main objective is the attenuation of spurious pressure field oscillations in regions with discontinuity in grid line slopes, as encountered in grids representing highly non-uniform terrains. Moreover, the approach relaxes the need for grid generation based on elliptic PDEs or grid smoothing by applying fixed point iterations (i.e. Gauss-Seidel to initial grid node positions resulting from algebraic grid generators. Drawbacks of previous approaches which ignored treatment of finite volume grid cell cases with intersection point offset in non-orthogonality corrections are removed. Application to real-life wind farm project at Dobrič (Srvljig, Serbia is used to assess the effectiveness of the method. The results validate the view in which accurate discretization of governing equations play more important role than the choice of turbulence modelling closures. [Projekat Ministarstva nauke Republike Srbije, br. TR-33036

  12. A two-dimensional finite element model of front surface current flow in cells under non-uniform, concentrated illumination

    Energy Technology Data Exchange (ETDEWEB)

    Mellor, A.; Domenech-Garret, J.L.; Chemisana, D.; Rosell, J.I. [Departament de Medi Ambient i C.S., University of Lleida, Av. Alcalde Rovira Roure 191, E25198 (Spain)

    2009-09-15

    A two-dimensional finite element model of current flow in the front surface of a PV cell is presented. In order to validate this model we perform an experimental test. Later, particular attention is paid to the effects of non-uniform illumination in the finger direction which is typical in a linear concentrator system. Fill factor, open circuit voltage and efficiency are shown to decrease with increasing degree of non-uniform illumination. It is shown that these detrimental effects can be mitigated significantly by reoptimization of the number of front surface metallization fingers to suit the degree of non-uniformity. The behavior of current flow in the front surface of a cell operating at open circuit voltage under non-uniform illumination is discussed in detail. (author)

  13. UVIS Flat Field Uniformity

    Science.gov (United States)

    Quijano, Jessica Kim

    2009-07-01

    The stability and uniformity of the low-frequency flat fields {L-flat} of the UVIS detector will be assessed by using multiple-pointing observations of the globular clusters 47 Tucanae {NGC104} and Omega Centauri {NGC5139}, thus imaging moderately dense stellar fields. By placing the same star over different portions of the detector and measuring relative changes in its brightness, it will be possible to determine local variations in the response of the UVIS detector. Based on previous experience with STIS and ACS, it is deemed that a total of 9 different pointings will suffice to provide adequate characterization of the flat field stability in any given band. For each filter to be tested, the baseline consists of 9 pointings in a 3X3 box pattern with dither steps of about 25% of the FOV, or 40.5", in either the x or y direction {useful also for CTE measurements, if needed in the future}. During SMOV, the complement of filters to be tested is limited to the following 6 filters: F225W, F275W, F336W, for Omega Cen, and F438W, F606W, and F814W for 47 Tuc. Three long exposures for each target are arranged such that the initial dither position is observed with the appropriate filters for that target within one orbit at a single pointing, so that filter-to-filter differences in the observed star positions can be checked. In addition to the 9 baseline exposures, two sets of short exposures will be taken:a} one short exposure will be taken of OmegaCen with each of the visible filters {F438W, F606W and F814W} in order to check the geometric distortion solution to be obtained with the data from proposal 11444;b} for each target, a single short exposure will be taken with each filter to facilitate the study of the PSF as a function of position on the detector by providing unsaturated images of sparsely-spaced bright stars.This proposal corresponds to Activity Description ID WF39. It should execute only after the following proposal has executed:WF21 - 11434

  14. Uniform magnetic targeting of magnetic particles attracted by a new ferromagnetic biological patch.

    Science.gov (United States)

    Pei, Ning; Cai, Lanlan; Yang, Kai; Ma, Jiaqi; Gong, Yongyong; Wang, Qixin; Huang, Zheyong

    2018-02-01

    A new non-toxic ferromagnetic biological patch (MBP) was designed in this paper. The MBP consisted of two external layers that were made of transparent silicone, and an internal layer that was made of a mixture of pure iron powder and silicon rubber. Finite-element analysis showed that the local inhomogeneous magnetic field (MF) around the MBP was generated when MBP was placed in a uniform MF. The local MF near the MBP varied with the uniform MF and shape of the MBP. Therefore, not only could the accumulation of paramagnetic particles be adjusted by controlling the strength of the uniform MF, but also the distribution of the paramagnetic particles could be improved with the different shape of the MBP. The relationship of the accumulation of paramagnetic particles or cells, magnetic flux density, and fluid velocity were studied through in vitro experiments and theoretical considerations. The accumulation of paramagnetic particles first increased with increment in the magnetic flux density of the uniform MF. But when the magnetic flux density of the uniform MF exceeded a specific value, the magnetic flux density of the MBP reached saturation, causing the accumulation of paramagnetic particles to fall. In addition, the adsorption morphology of magnetic particles or cells could be improved and the uniform distribution of magnetic particles could be achieved by changing the shape of the MBP. Also, MBP may be used as a new implant to attract magnetic drug carrier particles in magnetic drug targeting. Bioelectromagnetics. 39:98-107, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  15. Macroscopic spin-orbit coupling in non-uniform magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Tabat, N.; Edelman, H. S.; Song, D. [Semaphore Scientific, Inc., St. Cloud, Minnesota 56301 (United States); Vogt, T. [Department of Electrical and Computer Engineering, St. Cloud State University, St. Cloud, Minnesota 56301 (United States)

    2015-03-02

    Translational dynamics of aggregated magnetic nano-particles placed in a rotating external magnetic field is described. It is observed and explained that aggregates that spin within a radially decreasing field strength must execute an orbital motion of their center of mass in a sense that counters their spin rotation. This orbital motion is tightly coupled to the spin dynamics of the aggregates. An analytical model for the canonical variables describing the orbital motion is derived and shown to be in good agreement with the measured values.

  16. Macroscopic spin-orbit coupling in non-uniform magnetic fields

    International Nuclear Information System (INIS)

    Tabat, N.; Edelman, H. S.; Song, D.; Vogt, T.

    2015-01-01

    Translational dynamics of aggregated magnetic nano-particles placed in a rotating external magnetic field is described. It is observed and explained that aggregates that spin within a radially decreasing field strength must execute an orbital motion of their center of mass in a sense that counters their spin rotation. This orbital motion is tightly coupled to the spin dynamics of the aggregates. An analytical model for the canonical variables describing the orbital motion is derived and shown to be in good agreement with the measured values

  17. Exact Finite Differences. The Derivative on Non Uniformly Spaced Partitions

    Directory of Open Access Journals (Sweden)

    Armando Martínez-Pérez

    2017-10-01

    Full Text Available We define a finite-differences derivative operation, on a non uniformly spaced partition, which has the exponential function as an exact eigenvector. We discuss some properties of this operator and we propose a definition for the components of a finite-differences momentum operator. This allows us to perform exact discrete calculations.

  18. Prevention of Bridge Scour with Non-uniform Circular Piers Plane under Steady Flows

    Science.gov (United States)

    Chen, Hsing-Ting; Wang, Chuan-Yi

    2017-04-01

    River bed scour and deposit variation extremely severe because of most of rivers are steep and rapid flows, and river discharge extremely unstable and highly unsteady during different seasons in Taiwan. In addition to the obstruction of piers foundation, it causes local scour and threatens the safety of bridges. In the past, riprap, wire gabion or wrap pier works were adopted as the protections of piers foundation, but there were no effectual outcomes. The events of break off piers still happen sometimes. For example, typhoon Kalmaegi (2008) and Morakot (2009) caused heavy damages on Ho-Fon bridge in the Da-jia river and Shuang-Yuan bridge in the Kao-Ping river, respectively. Accordingly, to understand the piers scour system and propose an appropriate protection of piers foundation becomes an important topic for this study currently. This research improves the protection works of the existing uniform bridge pier (diameter D) to ensure the safety of the bridge. The non-uniform plane of circular piers (diameter D*) are placed on the top of a bridge pier foundation to reduce the down flow impacting energy and scour by its' surface roughness characteristics. This study utilize hydraulic models to simulate local scour depth and scour depth change with time for non-uniform pier diameter ratio D/D* of 0.3,0.4,0.5,0.6,0.7 and 0.8, and different type pier and initial bed level (Y) relative under the foundation top elevation under steady flows of V/Vc=0.95,0.80 and 0.65. The research results show that the scour depth increases with an increase of flow intensity (V/Vc) under different types of steady flow hydrographs. The scour depth decreases with increase of initial bed level (Y=+0.2D*,0D*and -0.2D*) relative under the foundation top elevation of the different type pier. The maximum scour depth occurred in the front of the pier for all conditions. Because of the scouring retardation by the non-uniform plane of foundation, the scour depth is reduced for the un-exposed bridge

  19. CHF multiplier of subcooled flow boiling for non-uniform heating conditions in swirl tube

    International Nuclear Information System (INIS)

    Inasaka, F.; Nariai, H.

    1994-01-01

    The high heat flux components of fusion reactors, such as divertor plates and beam dumps of neutral beam injectors, are estimated to be subjected to very high heat loads more than 10 MW/m 2 . Critical heat flux (CHF), which determines the upper limit of heat removal, is one of the most important problems in designing cooling systems. For practical applications in cooling systems, subcooled flow boiling in water combined with swirl-flow in tubes with internal twisted tape is thought to be the most superior for CHF characteristics in fusion reactor components, heat by irradiation comes in from one side of the wall, and cooling channel is then under circumferentially non-uniform heating condition. Authors have conducted the experiments on the CHF with internal twisted tapes under circumferentially non-uniform heating conditions and showed that when the intensity of non-uniformity increased, q cH (peak heat flux at burnout under nonuniform heating condition) in tube with internal twisted tape increased above the q c,unif (CHF under uniform heating condition), though the average qualities were the same for both cases. They also showed that this CHF enhancement was not seen in smooth tubes without tape under the same average qualities

  20. Environmental radionuclide concentrations: statistical model to determine uniformity of distribution

    International Nuclear Information System (INIS)

    Cawley, C.N.; Fenyves, E.J.; Spitzberg, D.B.; Wiorkowski, J.; Chehroudi, M.T.

    1980-01-01

    In the evaluation of data from environmental sampling and measurement, a basic question is whether the radionuclide (or pollutant) is distributed uniformly. Since physical measurements have associated errors, it is inappropriate to consider the measurements alone in this determination. Hence, a statistical model has been developed. It consists of a weighted analysis of variance with subsequent t-tests between weighted and independent means. A computer program to perform the calculations is included

  1. High density, uniformly distributed W/UO{sub 2} for use in Nuclear Thermal Propulsion

    Energy Technology Data Exchange (ETDEWEB)

    Tucker, Dennis S., E-mail: dr.dennis.tucker@nasa.gov [EM32, MSFC, Al 35812 (United States); Barnes, Marvin W. [EM32, MSFC, Al 35812 (United States); Hone, Lance; Cook, Steven [Center for Space Nuclear Research, Idaho Falls, ID 83401 (United States)

    2017-04-01

    An inexpensive, quick method has been developed to obtain uniform distributions of UO{sub 2} particles in a tungsten matrix utilizing 0.5 wt percent low density polyethylene. Powders were sintered in a Spark Plasma Sintering (SPS) furnace at 1600 °C, 1700 °C, 1750 °C, 1800 °C and 1850 °C using a modified sintering profile. This resulted in a uniform distribution of UO{sub 2} particles in a tungsten matrix with high densities, reaching 99.46% of theoretical for the sample sintered at 1850 °C. The powder process is described and the results of this study are given below.

  2. Creep to inertia dominated stick-slip behavior in sliding friction modulated by tilted non-uniform loading

    Science.gov (United States)

    Tian, Pengyi; Tao, Dashuai; Yin, Wei; Zhang, Xiangjun; Meng, Yonggang; Tian, Yu

    2016-09-01

    Comprehension of stick-slip motion is very important for understanding tribological principles. The transition from creep-dominated to inertia-dominated stick-slip as the increase of sliding velocity has been described by researchers. However, the associated micro-contact behavior during this transition has not been fully disclosed yet. In this study, we investigated the stick-slip behaviors of two polymethyl methacrylate blocks actively modulated from the creep-dominated to inertia-dominated dynamics through a non-uniform loading along the interface by slightly tilting the angle of the two blocks. Increasing the tilt angle increases the critical transition velocity from creep-dominated to inertia-dominated stick-slip behaviors. Results from finite element simulation disclosed that a positive tilt angle led to a higher normal stress and a higher temperature on blocks at the opposite side of the crack initiating edge, which enhanced the creep of asperities during sliding friction. Acoustic emission (AE) during the stick-slip has also been measured, which is closely related to the different rupture modes regulated by the distribution of the ratio of shear to normal stress along the sliding interface. This study provided a more comprehensive understanding of the effect of tilted non-uniform loading on the local stress ratio, the local temperature, and the stick-slip behaviors.

  3. Non-Maxwellian and magnetic field effects in complex plasma wakes★

    Science.gov (United States)

    Ludwig, Patrick; Jung, Hendrik; Kählert, Hanno; Joost, Jan-Philip; Greiner, Franko; Moldabekov, Zhandos; Carstensen, Jan; Sundar, Sita; Bonitz, Michael; Piel, Alexander

    2018-05-01

    In a streaming plasma, negatively charged dust particles create complex charge distributions on the downstream side of the particle, which are responsible for attractive forces between the like-charged particles. This wake phenomenon is studied by means of refined linear response theory and molecular dynamics simulations as well as in experiments. Particular attention is paid to non-Maxwellian velocity distributions that are found in the plasma sheath and to situations with strong magnetic fields, which are becoming increasingly important. Non-Maxwellian distributions and strong magnetic fields result in a substantial damping of the oscillatory wake potential. The interaction force in particle pairs is explored with the phase-resolved resonance method, which demonstrates the non-reciprocity of the interparticle forces in unmagnetized and magnetized systems.

  4. Quantitative non-monotonic modeling of economic uncertainty by probability and possibility distributions

    DEFF Research Database (Denmark)

    Schjær-Jacobsen, Hans

    2012-01-01

    uncertainty can be calculated. The possibility approach is particular well suited for representation of uncertainty of a non-statistical nature due to lack of knowledge and requires less information than the probability approach. Based on the kind of uncertainty and knowledge present, these aspects...... to the understanding of similarities and differences of the two approaches as well as practical applications. The probability approach offers a good framework for representation of randomness and variability. Once the probability distributions of uncertain parameters and their correlations are known the resulting...... are thoroughly discussed in the case of rectangular representation of uncertainty by the uniform probability distribution and the interval, respectively. Also triangular representations are dealt with and compared. Calculation of monotonic as well as non-monotonic functions of variables represented...

  5. Beam uniformity of flat top lasers

    Science.gov (United States)

    Chang, Chao; Cramer, Larry; Danielson, Don; Norby, James

    2015-03-01

    Many beams that output from standard commercial lasers are multi-mode, with each mode having a different shape and width. They show an overall non-homogeneous energy distribution across the spot size. There may be satellite structures, halos and other deviations from beam uniformity. However, many scientific, industrial and medical applications require flat top spatial energy distribution, high uniformity in the plateau region, and complete absence of hot spots. Reliable standard methods for the evaluation of beam quality are of great importance. Standard methods are required for correct characterization of the laser for its intended application and for tight quality control in laser manufacturing. The International Organization for Standardization (ISO) has published standard procedures and definitions for this purpose. These procedures have not been widely adopted by commercial laser manufacturers. This is due to the fact that they are unreliable because an unrepresentative single-pixel value can seriously distort the result. We hereby propose a metric of beam uniformity, a way of beam profile visualization, procedures to automatically detect hot spots and beam structures, and application examples in our high energy laser production.

  6. The non-uniformity correction factor for the cylindrical ionization chambers in dosimetry of an HDR 192Ir brachytherapy source

    International Nuclear Information System (INIS)

    Majumdar, Bishnu; Patel, Narayan Prasad; Vijayan, V.

    2006-01-01

    The aim of this study is to derive the non-uniformity correction factor for the two therapy ionization chambers for the dose measurement near the brachytherapy source. The two ionization chambers of 0.6 cc and 0.1 cc volume were used. The measurement in air was performed for distances between 0.8 cm and 20 cm from the source in specially designed measurement jig. The non-uniformity correction factors were derived from the measured values. The experimentally derived factors were compared with the theoretically calculated non-uniformity correction factors and a close agreement was found between these two studies. The experimentally derived non-uniformity correction factor supports the anisotropic theory. (author)

  7. Principles of nuclear magnetic resonance imaging using an inhomogeneous polarizing field

    International Nuclear Information System (INIS)

    Briguet, A.; Chaillout, J.; Goldman, M.

    1985-01-01

    In this paper, it is indicated how to reconstruct nuclear magnetic resonance images acquired in an inhomogeneous static magnetic field without the previous knowledge of its spatial distribution. The method provides also the map of the static magnetic field through the sample volume; furthermore it allows the use of non uniform but spatially controlled encoding gradients [fr

  8. 1RXS J180834.7+101041 is a new cataclysmic variable with non-uniform disc

    Science.gov (United States)

    Yakin, D. G.; Suleimanov, V. F.; Shimansky, V. V.; Borisov, N. V.; Bikmaev, I. F.; Sakhibullin, N. A.

    2010-11-01

    Results of photometric and spectroscopic investigations of the recently discovered disc cataclysmic variable star 1RXS J180834.7+101041 are presented. Emission spectra of the system show broad double peaked hydrogen and helium emission lines. Doppler maps for the hydrogen lines demonstrate strongly non-uniform emissivity distribution in the disc, similar to that found in IP Peg. It means that the system is a new cataclysmic variable with a spiral density wave in the disc. Masses of the components (MWD = 0.8+/-0.22 Msolar and MRD = 0.14+/-0.02 Msolar), and the orbit inclination (i = 78°+/- 1.°5) were estimated using the various well-known relations for cataclysmic variables.

  9. Non-uniform dispersion of the source-sink relationship alters wavefront curvature.

    Directory of Open Access Journals (Sweden)

    Lucia Romero

    Full Text Available The distribution of cellular source-sink relationships plays an important role in cardiac propagation. It can lead to conduction slowing and block as well as wave fractionation. It is of great interest to unravel the mechanisms underlying evolution in wavefront geometry. Our goal is to investigate the role of the source-sink relationship on wavefront geometry using computer simulations. We analyzed the role of variability in the microscopic source-sink relationship in driving changes in wavefront geometry. The electrophysiological activity of a homogeneous isotropic tissue was simulated using the ten Tusscher and Panfilov 2006 action potential model and the source-sink relationship was characterized using an improved version of the Romero et al. safety factor formulation (SFm2. Our simulations reveal that non-uniform dispersion of the cellular source-sink relationship (dispersion along the wavefront leads to alterations in curvature. To better understand the role of the source-sink relationship in the process of wave formation, the electrophysiological activity at the initiation of excitation waves in a 1D strand was examined and the source-sink relationship was characterized using the two recently updated safety factor formulations: the SFm2 and the Boyle-Vigmond (SFVB definitions. The electrophysiological activity at the initiation of excitation waves was intimately related to the SFm2 profiles, while the SFVB led to several counterintuitive observations. Importantly, with the SFm2 characterization, a critical source-sink relationship for initiation of excitation waves was identified, which was independent of the size of the electrode of excitation, membrane excitability, or tissue conductivity. In conclusion, our work suggests that non-uniform dispersion of the source-sink relationship alters wavefront curvature and a critical source-sink relationship profile separates wave expansion from collapse. Our study reinforces the idea that the

  10. Energy-Efficient Algorithm for Sensor Networks with Non-Uniform Maximum Transmission Range

    Directory of Open Access Journals (Sweden)

    Yimin Yu

    2011-06-01

    Full Text Available In wireless sensor networks (WSNs, the energy hole problem is a key factor affecting the network lifetime. In a circular multi-hop sensor network (modeled as concentric coronas, the optimal transmission ranges of all coronas can effectively improve network lifetime. In this paper, we investigate WSNs with non-uniform maximum transmission ranges, where sensor nodes deployed in different regions may differ in their maximum transmission range. Then, we propose an Energy-efficient algorithm for Non-uniform Maximum Transmission range (ENMT, which can search approximate optimal transmission ranges of all coronas in order to prolong network lifetime. Furthermore, the simulation results indicate that ENMT performs better than other algorithms.

  11. Acoustic holography for piston sound radiation with non-uniform velocity profiles

    NARCIS (Netherlands)

    Aarts, R.M.; Janssen, A.J.E.M.

    2010-01-01

    The theory of orthogonal (Zernike) expansions of functions on a disk, as used in the diffraction theory of optical aberrations, is applied to obtain (semi-) analytical results for the radiation of sound due to a non-uniformly moving, baffled, circular piston. For this particular case, a scheme for

  12. The development of criteria for limiting the non-stochastic effects of non-uniform skin exposure

    International Nuclear Information System (INIS)

    Charles, M.W.; Wells, J.

    1980-01-01

    The recent recommendations of the International Commission on Radiological Protection (ICRP, 1977) have underlined the lack of knowledge relating to small area skin exposures and have highlighted the difficulties of integrating stochastic and nonstochastic effects into a unified radiation protection philosophy. A system of limitation is suggested which should be appropriate to the wide range of skin irradiation modes which are met in practice. It is proposed for example, that for large area exposures, the probability of skin cancer induction should be considered as the limiting factor. For partial-body skin exposures the probability of the stochastic response will be reduced and late nonstochastic effects will become limiting as the area exposed is reduced. Highly non-uniform exposures such as from small sources or radioactive particulates should be limited on the basis of early rather than late effects. A survey of epidemiological and experimental work is used to show how detailed guidance for limitation in these cases can be provided. Due to the detailed morphology of the skin the biological response depends critically upon the depth dose. In the case of alpha and beta radiation this should be reflected in a less restrictive limitation system, particularly for non-stochastic effects. Up-to-date and on-going experimental studies are described which can provide guidance in this field. (author)

  13. The Superconvergence Phenomenon and Proof of the MAC Scheme for the Stokes Equations on Non-uniform Rectangular Meshes

    KAUST Repository

    Li, Jichun

    2014-12-02

    For decades, the widely used finite difference method on staggered grids, also known as the marker and cell (MAC) method, has been one of the simplest and most effective numerical schemes for solving the Stokes equations and Navier–Stokes equations. Its superconvergence on uniform meshes has been observed by Nicolaides (SIAM J Numer Anal 29(6):1579–1591, 1992), but the rigorous proof is never given. Its behavior on non-uniform grids is not well studied, since most publications only consider uniform grids. In this work, we develop the MAC scheme on non-uniform rectangular meshes, and for the first time we theoretically prove that the superconvergence phenomenon (i.e., second order convergence in the (Formula presented.) norm for both velocity and pressure) holds true for the MAC method on non-uniform rectangular meshes. With a careful and accurate analysis of various sources of errors, we observe that even though the local truncation errors are only first order in terms of mesh size, the global errors after summation are second order due to the amazing cancellation of local errors. This observation leads to the elegant superconvergence analysis even with non-uniform meshes. Numerical results are given to verify our theoretical analysis.

  14. Quark pair creation in color electric fields and effects of magnetic fields

    International Nuclear Information System (INIS)

    Tanji, Noato

    2010-01-01

    The time evolution of a system where a uniform and classical SU(3) color electric field and quantum fields of quarks interact with each other is studied focusing on non-perturbative pair creation and its back reaction. We characterize a color direction of an electric field in a gauge invariant way, and investigate its dependence. Momentum distributions of created quarks show plasma oscillation as well as quantum effects such as the Pauli blocking and interference. Pressure of the system is also calculated, and we show that pair creation moderates degree of anisotropy of pressure. Furthermore, enhancement of pair creation and induction of chiral charge under a color magnetic field which is parallel to an electric field are discussed.

  15. A METHOD FOR EVALUATION OF NON-UNIFORM RADIANT-CONVECTIVE LOAD ON HUMAN BODY DURING MENTAL WORK

    Directory of Open Access Journals (Sweden)

    Lenka Prokšová Zuská

    2017-10-01

    Full Text Available The objective of this study was to develop a documentation for the amendment of the microclimatic part of the Czech Government Regulation, particularly in a non-uniform radiant-convective load evaluation. Changes in regulation were made based on experimental data obtained on a group of experimental individuals in a climatic chamber. One of the objectives of the climatic chamber experiments was to evaluate whether there was a possibility to use an alternative method, which utilizes a new value – stereotemperature, for the assessment. A group of 24 women was exposed to a non-uniform radiant-convective load in a climatic chamber for 1 hour during their computer work. Measurements were divided according to the globe temperature into 3 stages. The physical parameters of air were continuously measured: the air temperature, globe temperature, air velocity, radiant temperature, relative humidity, stereotemperature and physiological parameters. Thermal sensations of experimental subjects were expressed in the seven-point scale according to EN ISO 7730. The thermal sensation correlated very well with the difference of stereotemperature and the globe temperature. The stereotemperature correlated very well with the radiant temperature. In this work, the composed equations were used to develop the limit values for the thermal stress evaluation in the uniform and non-uniform thermal environment at workplaces. It is possible to determine how the body of an exposed person perceives the non-uniform climatic conditions in the indoor environment, by adding the stereotemperature to government regulations.

  16. Number theory Diophantine problems, uniform distribution and applications : festschrift in honour of Robert F. Tichy’s 60th birthday

    CERN Document Server

    Grabner, Peter

    2017-01-01

    This volume is dedicated to Robert F. Tichy on the occasion of his 60th birthday. Presenting 22 research and survey papers written by leading experts in their respective fields, it focuses on areas that align with Tichy’s research interests and which he significantly shaped, including Diophantine problems, asymptotic counting, uniform distribution and discrepancy of sequences (in theory and application), dynamical systems, prime numbers, and actuarial mathematics. Offering valuable insights into recent developments in these areas, the book will be of interest to researchers and graduate students engaged in number theory and its applications.

  17. From conventional averages to individual dose painting in radiotherapy for human tumors: challenge to non-uniformity

    International Nuclear Information System (INIS)

    Maciejewski, B.; Rodney Withers, H.

    2004-01-01

    The exploitation of a number of current clinical trials and reports on outcomes after radiation therapy (i.e. breast, head and neck, prostate) in clinical practice reflects many limitations for conventional techniques and dose-fractionation schedules and for 'average' conclusions. Even after decades of evolution of radiation therapy we still do not know how to optimize treatment for the individual patient and only have 'averages' and ill-defined 'probabilities' to guide treatment prescription. Wide clinical and biological heterogeneity within the groups of patients recruited into clinical trials with a few-fold variation in tumour volume within one stage of disease is obvious. Basic radiobiological guidelines concerning average cell killing of uniformly distributed and equally radiosensitive tumour cells arose from elegant but idealistic in vitro experiments and seem to be of uncertain validity. Therefore, we are confronted with more dilemmas than dogmas. Nonlinearity and in homogeneity of human tumour pattern and response to irradiation are discussed. The purpose of this paper is to present and discuss various aspects of non-uniform tumour cell targeted radiotherapy using conformal and dose intensity modulated techniques. (author)

  18. Commencement of the Couette flow in the Oldroyd liquid with heat sources and in the presence of a uniform transverse magnetic field

    International Nuclear Information System (INIS)

    Biswal, S.; Pattnaik, B.K.

    1996-01-01

    Commencement of the Couette flow in Oldroyd liquid has been studied in the presence of a uniform transverse magnetic field with heat sources/sinks. Constitutive equations of motion and energy have been formulated and solved with the aid of Galerkin technique. Expressions for velocity, temperature, skin frictions and rates of heat transfer are obtained. With Fortran language, the values of velocity, temperature, shear-stresses at the lower and upper plates and the rates of heat transfer at the plates have been evaluated after necessary computations. The results have been shown by graphs and tables for different values of various parameters like R, R c , P m , t, n, P r , E and S. Velocity and temperature distribution are shown by graphs while the values of shear-stresses and Nusselts numbers at the plates are entered in tables. It is observed that the flow is sensitive to the interactions of heat source/sink, elasticity of the fluid and the imposed magnetic field strength. The amount of heat energy propagated during this process of non-Newtonian flow varies appreciably with R, S and P r . The heat absorbing sink or the heat generating source influences the temperature field to a great extent. (author)

  19. Demonstration of motion control of ZrO2 microparticles in uniform/non-uniform electric field

    Science.gov (United States)

    Onishi, Genki; Trung, Ngo Nguyen Chi; Matsutani, Naoto; Nakayama, Tadachika; Suzuki, Tsuneo; Suematsu, Hisayuki; Niihara, Koichi

    2018-02-01

    This study aims to elucidate the mechanism that drives dielectric microparticles under an electric field. The driving of microstructures is affected by various electrical phenomena occurring at the same time such as surface potential, polarization, and electrostatic force. It makes the clarification of the driving mechanism challenging. A simple experimental system was used to observe the behavior of spherical ZrO2 microparticles in a nonaqueous solution under an electric field. The results suggest that the mechanism that drives the ZrO2 microparticles under an electric field involved the combination of an electric image force, a gradient force, and the contact charging phenomenon. A method is proposed to control the motion of micro- and nanostructures in further study and applications.

  20. Effect of heat transfer on unsteady MHD flow of blood in a permeable vessel in the presence of non-uniform heat source

    OpenAIRE

    A. Sinha; J.C. Misra; G.C. Shit

    2016-01-01

    This paper presents a theoretical analysis of blood flow and heat transfer in a permeable vessel in the presence of an external magnetic field. The unsteadiness in the coupled flow and temperature fields is considered to be caused due to the time-dependent stretching velocity and the surface temperature of the vessel. The non-uniform heat source/sink effect on blood flow and heat transfer is taken into account. This study is of potential value in the clinical treatment of cardiovascular disor...

  1. Fabrication and electrorotation of a novel epoxy based micromotor working in a uniform DC electric field

    Science.gov (United States)

    Bauer, Rita A.; Kelemen, Lóránd; Nakano, Masami; Totsuka, Atsushi; Zrínyi, Miklós

    2015-10-01

    We have presented the first direct observation of electric field induced rotation of epoxy based polymer rotors. Polymer disks, hollow cylinders and gears were prepared in few micrometer dimensions as rotors. Electrorotation of these sub-millimeter sized tools was studied under uniform dc electric field. The effects of shape, size and thickness were investigated. The novel epoxy based micro devices show intensive spinning in a uniform dc electric field. The rotational speed of micron-sized polymer rotors can be conveniently tuned in a wide range (between 300 and 3000 rpm) by the electric field intensity, opening new perspectives for their use in several MEMS applications.

  2. Fabrication and electrorotation of a novel epoxy based micromotor working in a uniform DC electric field

    International Nuclear Information System (INIS)

    Bauer, Rita A; Zrínyi, Miklós; Kelemen, Lóránd; Nakano, Masami; Totsuka, Atsushi

    2015-01-01

    We have presented the first direct observation of electric field induced rotation of epoxy based polymer rotors. Polymer disks, hollow cylinders and gears were prepared in few micrometer dimensions as rotors. Electrorotation of these sub-millimeter sized tools was studied under uniform dc electric field. The effects of shape, size and thickness were investigated. The novel epoxy based micro devices show intensive spinning in a uniform dc electric field. The rotational speed of micron-sized polymer rotors can be conveniently tuned in a wide range (between 300 and 3000 rpm) by the electric field intensity, opening new perspectives for their use in several MEMS applications. (paper)

  3. Improvement of quantitation in SPECT: Attenuation and scatter correction using non-uniform attenuation data

    International Nuclear Information System (INIS)

    Mukai, T.; Torizuka, K.; Douglass, K.H.; Wagner, H.N.

    1985-01-01

    Quantitative assessment of tracer distribution with single photon emission computed tomography (SPECT) is difficult because of attenuation and scattering of gamma rays within the object. A method considering the source geometry was developed, and effects of attenuation and scatter on SPECT quantitation were studied using phantoms with non-uniform attenuation. The distribution of attenuation coefficients (μ) within the source were obtained by transmission CT. The attenuation correction was performed by an iterative reprojection technique. The scatter correction was done by convolution of the attenuation corrected image and an appropriate filter made by line source studies. The filter characteristics depended on μ and SPEC measurement at each pixel. The SPECT obtained by this method showed the most reasonable results than the images reconstructed by other methods. The scatter correction could compensate completely for a 28% scatter components from a long line source, and a 61% component for thick and extended source. Consideration of source geometries was necessary for effective corrections. The present method is expected to be valuable for the quantitative assessment of regional tracer activity

  4. Spinal cord tolerance to single-session uniform irradiation in pigs: Implications for a dose-volume effect

    International Nuclear Information System (INIS)

    Medin, Paul M.; Foster, Ryan D.; Kogel, Albert J. van der; Sayre, James W.; McBride, William H.; Solberg, Timothy D.

    2013-01-01

    Background and purpose: This study was performed to test the hypothesis that spinal cord radiosensitivity is significantly modified by uniform versus laterally non-uniform dose distributions. Materials and methods: A uniform dose distribution was delivered to a 4.5–7.0 cm length of cervical spinal cord in 22 mature Yucatan minipigs for comparison with a companion study in which a laterally non-uniform dose was given [1]. Pigs were allocated into four dose groups with mean maximum spinal cord doses of 17.5 ± 0.1 Gy (n = 7), 19.5 ± 0.2 Gy (n = 6), 22.0 ± 0.1 Gy (n = 5), and 24.1 ± 0.2 Gy (n = 4). The study endpoint was motor neurologic deficit determined by a change in gait within one year. Spinal cord sections were stained with a Luxol fast blue/periodic acid Schiff combination. Results: Dose–response curves for uniform versus non-uniform spinal cord irradiation were nearly identical with ED 50 ’s (95% confidence interval) of 20.2 Gy (19.1–25.8) and 20.0 Gy (18.3–21.7), respectively. No neurologic change was observed for either dose distribution when the maximum spinal cord dose was ⩽17.8 Gy while all animals experienced deficits at doses ⩾21.8 Gy. Conclusion: No dose-volume effect was observed in pigs for the dose distributions studied and the endpoint of motor neurologic deficit; however, partial spinal cord irradiation resulted in less debilitating neurologic morbidity and histopathology

  5. Measuring diffusion-relaxation correlation maps using non-uniform field gradients of single-sided NMR devices.

    Science.gov (United States)

    Nogueira d'Eurydice, Marcel; Galvosas, Petrik

    2014-11-01

    Single-sided NMR systems are becoming a relevant tool in industry and laboratory environments due to their low cost, low maintenance and capacity to evaluate quantity and quality of hydrogen based materials. The performance of such devices has improved significantly over the last decade, providing increased field homogeneity, field strength and even controlled static field gradients. For a class of these devices, the configuration of the permanent magnets provides a linear variation of the magnetic field and can be used in diffusion measurements. However, magnet design depends directly on its application and, according to the purpose, the field homogeneity may significantly be compromised. This may prevent the determination of diffusion properties of fluids based on the natural inhomogeneity of the field using known techniques. This work introduces a new approach that extends the applicability of diffusion-editing CPMG experiments to NMR devices with highly inhomogeneous magnetic fields, which do not vary linearly in space. Herein, we propose a method to determine a custom diffusion kernel based on the gradient distribution, which can be seen as a signature of each NMR device. This new diffusion kernel is then utilised in the 2D inverse Laplace transform (2D ILT) in order to determine diffusion-relaxation correlation maps of homogeneous multi-phasic fluids. The experiments were performed using NMR MObile Lateral Explore (MOLE), which is a single-sided NMR device designed to maximise the volume at the sweet spot with enhanced depth penetration. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Influence of initial velocity on trajectories of a charged particle in uniform crossed electric and magnetic fields

    International Nuclear Information System (INIS)

    Khotimah, Siti Nurul; Viridi, Sparisoma; Widayani

    2017-01-01

    Magnetic and electric fields can cause a charged particle to form interesting trajectories. In general, each trajectory is discussed separately in university physics textbooks for undergraduate students. In this work, a solution of a charged particle moving in a uniform electric field at right angles to a uniform magnetic field (uniform crossed electric and magnetic fields) is reported; it is limited to particle motion in a plane. Specific solutions and their trajectories are obtained only by varying the initial particle velocity. The result shows five basic trajectory patterns, i.e., straight line, sinusoid-like, cycloid, cycloid-like with oscillation, and circle-like. The region of each trajectory is also mapped in the initial velocity space of the particle. This paper is intended for undergraduate students and describes further the trajectories of a charged particle through the regions of electric and magnetic fields influenced by initial condition of the particle, where electromagnetic radiation of an accelerated particle is not considered. (paper)

  7. Some problems concerning the regularities in the development of the latitudinal distribution of solar magnetic fields

    International Nuclear Information System (INIS)

    Bumba, V.; Hejna, L.

    1988-01-01

    From the comparison of several modes of time development of the latitudinal distribution of solar magnetic fields, obtained by different authors using different basic observational material and different methods, the following results were obtained: At high solar latitudes (|φ|> or ∼ 40deg) all distributions agree irrespective of the method of construction. In zones of activity around the solar equator, there is a qualitatively good but quantitatively poor agreement of the integrated, directly observed fields (from Mt. Wilson Observatory) and of the highly integrated fields derived from Hα synoptic charts. The mode of field distribution at high latitudes, more uniform and unipolar, is probably different from the field distribution at low latitudes where the more concentrated leading polarity occupies practically the same area as the less concentrated following polarity fields, if they are highly integrated. The large difference between Makarov's distribution and other modes of distribution seems to be natural if we take the method of construction into account, and very probably represents its close relationship with the smaller magnetic field elements connected with newer activity, while the other types of distribution demonstrate larger-scale, redistributed, older fields. The areas covered by the positive and negative polarities on the whole Sun during the investigated one and a half solar cycles (No 20 and 21) are practically equal. (author). 5 figs., 10 refs

  8. Fokker-Planck equation in the presence of a uniform magnetic field

    International Nuclear Information System (INIS)

    Dong, Chao; Zhang, Wenlu; Li, Ding

    2016-01-01

    The Fokker-Planck equation in the presence of a uniform magnetic field is derived which has the same form as the case of no magnetic field but with different Fokker-Planck coefficients. The coefficients are calculated explicitly within the binary collision model, which are free from infinite sums of Bessel functions. They can be used to investigate relaxation and transport phenomena conveniently. The kinetic equation is also manipulated into the Landau form from which it is straightforward to compare with previous results and prove the conservation laws.

  9. Fokker-Planck equation in the presence of a uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Chao, E-mail: chaodong@iphy.ac.cn [Center for Plasma Theory and Computation, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Department of Nuclear Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Zhang, Wenlu [Center for Plasma Theory and Computation, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Li, Ding, E-mail: dli@ustc.edu.cn [Center for Plasma Theory and Computation, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Department of Modern Physics, University of Science and Technology of China, Anhui Hefei 230026 (China)

    2016-08-15

    The Fokker-Planck equation in the presence of a uniform magnetic field is derived which has the same form as the case of no magnetic field but with different Fokker-Planck coefficients. The coefficients are calculated explicitly within the binary collision model, which are free from infinite sums of Bessel functions. They can be used to investigate relaxation and transport phenomena conveniently. The kinetic equation is also manipulated into the Landau form from which it is straightforward to compare with previous results and prove the conservation laws.

  10. Design of multiplier-less sharp non-uniform cosine modulated filter banks for efficient channelizers in software defined radio

    Directory of Open Access Journals (Sweden)

    Shaeen Kalathil

    2016-03-01

    Full Text Available Forthcoming software defined radios require filter banks which satisfy stringent specifications efficiently with low implementation complexity. Cosine modulated filter banks (CMFB have simple and efficient design procedure. The different wireless standards have different channel spacing or bandwidths and hence demand non-uniform decomposition of subbands. The non-uniform CMFB can be obtained from a uniform CMFB in a simple and efficient approach by merging the adjacent channels of the uniform CMFB. Very narrow transition width filters with low complexity can be achieved using frequency response masking (FRM filter as prototype filter. The complexity is further reduced by the multiplier-less realization of filter banks in which the least number of signed power of two (SPT terms is achieved by representing the filter coefficients using canonic signed digit (CSD representation and then optimizing using suitable modified meta-heuristic algorithms. Hybrid meta-heuristic algorithms are used in this paper. A hybrid algorithm combines the qualities of two meta-heuristic algorithms and results in improved performances with low implementation complexity. Highly frequency selective filter banks characterized by small passband ripple, narrow transition width and high stopband attenuation with non-uniform decomposition of subbands can be designed with least the implementation complexity, using this approach. A digital channelizer can be designed for SDR implementations, using the proposed approach. In this paper, the non-uniform CMFB is designed for various existing wireless standards.

  11. Theoretical investigations on two-phase flow instability in parallel channels under axial non-uniform heating

    International Nuclear Information System (INIS)

    Lu, Xiaodong; Wu, Yingwei; Zhou, Linglan; Tian, Wenxi; Su, Guanghui; Qiu, Suizheng; Zhang, Hong

    2014-01-01

    Highlights: • We developed a model based on homogeneous flow model to analyze two-phase flow instability in parallel channels. • The influence of axial non-uniform heating on the system stability has been investigated. • Influences of various factors on system instability under cosine heat flux have been studied. • The system under top-peaked heat flux is the most stable system. - Abstract: Two-phase flow instability in parallel channels heated by axial non-uniform heat flux has been theoretically studied in this paper. The system control equations of parallel channels were established based on the homogeneous flow model in two-phase region. Semi-implicit finite-difference scheme and staggered mesh method were used to discretize the equations, and the difference equations were solved by chasing method. Cosine, bottom-peaked and top-peaked heat fluxes were used to study the influence of non-uniform heating on two-phase flow instability of the parallel channels system. The marginal stability boundaries (MSB) of parallel channels and three-dimensional instability spaces (or instability reefs) under different heat flux conditions have been obtained. Compared with axial uniform heating, axial non-uniform heating will affect the system stability. Cosine and bottom-peaked heat fluxes can destabilize the system stability in high inlet subcooling region, while the opposite effect can be found in low inlet subcooling region. However, top-peaked heat flux can enhance the system stability in the whole region. In addition, for cosine heat flux, increasing the system pressure or inlet resistance coefficient can strengthen the system stability, and increasing the heating power will destabilize the system stability. The influence of inlet subcooling number on the system stability is multi-valued under cosine heat flux

  12. Magneto-acoustic resonance in a non-uniform current carrying plasma column

    OpenAIRE

    Vaclavik, J.

    2017-01-01

    The forced radial magneto-acoustic oscillations in a plasma column with nonuniform mass density and temperature are investigated. It turns out that the oscillations have a resonant character similar to that of the magneto-acoustic oscillations in a uniform plasma column. The properties of the axial and azimuthal components of the oscillating magnetic field are discussed in detail

  13. In-plane modal frequencies and mode shapes of two stay cables interconnected by uniformly distributed cross-ties

    Science.gov (United States)

    Jing, Haiquan; He, Xuhui; Zou, Yunfeng; Wang, Hanfeng

    2018-03-01

    Stay cables are important load-bearing structural elements of cable-stayed bridges. Suppressing the large vibrations of the stay cables under the external excitations is of worldwide concern for the bridge engineers and researchers. Over the past decade, the use of crosstie has become one of the most practical and effective methods. Extensive research has led to a better understanding of the mechanics of cable networks, and the effects of different parameters, such as length ratio, mass-tension ratio, and segment ratio on the effectiveness of the crosstie have been investigated. In this study, uniformly distributed elastic crossties serve to replace the traditional single, or several cross-ties, aiming to delay "mode localization." A numerical method is developed by replacing the uniformly distributed, discrete elastic cross-tie model with an equivalent, continuously distributed, elastic cross-tie model in order to calculate the modal frequencies and mode shapes of the cable-crosstie system. The effectiveness of the proposed method is verified by comparing the elicited results with those obtained using the previous method. The uniformly distributed elastic cross-ties are shown to significantly delay "mode localization."

  14. Amplitude variations of ELF radio waves in the Earth-ionosphere cavity with the day-night non-uniformity

    Science.gov (United States)

    Galuk, Yu P.; Nickolaenko, A. P.; Hayakawa, M.

    2018-04-01

    The real structure of lower ionosphere should be taken into account when modeling the sub-ionospheric radio propagation in the extremely low frequency (ELF) band and studying the global electromagnetic (Schumann) resonance of the Earth-ionosphere cavity. In the present work we use the 2D (two dimensional) telegraph equations (2DTE) for evaluating the effect of the ionosphere day-night non-uniformity on the electromagnetic field amplitude at the Schumann resonance and higher frequencies. Properties of the cavity upper boundary were taken into account by the full wave solution technique for realistic vertical profiles of atmosphere conductivity in the ambient day and ambient night conditions. We solved the electromagnetic problem in a cavity with the day-night non-uniformity by using the 2DTE technique. Initially, the testing of the 2DTE solution was performed in the model of the sharp day-night interface. The further computations were carried out in the model of the smooth day-night transition. The major attention was directed to the effects at propagation paths "perpendicular" or "parallel" to the solar terminator line. Data were computed for a series of frequencies, the comparison of the results was made and interpretation was given to the observed effects.

  15. Design of a collector shape for uniform flow distribution in microchannels

    International Nuclear Information System (INIS)

    Siddique, Ayyaz; Agrawal, Amit; Saha, Sandip K; Medhi, Bhaskar J; Singh, Anugrah

    2017-01-01

    The focus of this study is the design of a collector with the objective of achieving uniform flow in multiple parallel microchannels. This objective is achieved by understanding the limitations of current designs and a novel design is proposed, which is further carefully optimized. The existing collector shape considered is U-type, which is investigated numerically. The creation of a stagnation zone, growth of a boundary layer along the collector wall and low/high velocity zones in the collector are identified as the prime causes of flow maldistribution. A novel design, a dumbbell shape collector, is proposed to overcome the limitations of the earlier designs. The dumbbell shape is evaluated quantitatively and is found to perform better than all existing shapes. This dumbbell shape collector provides a uniform flow distribution with less than 0.4% relative difference from the average flow rate in different channels, which is substantially better than existing collectors with 2.3% relative difference from the average flow rate for Re ch   =  32. The uniformity is further confirmed using micro-particle image velocimetry measurements. The dumbbell shape collector is generalized and optimized to cater to heat sinks of different dimensions and to broaden its applicability in both micro and macro dimensions. (paper)

  16. Uniform magnetic field in the bending magneto for the compact proton synchrotron

    CERN Document Server

    Tokura, S; Miyauchi, Y; Nakajima, S; Arakawa, M

    2003-01-01

    Radiation therapy using high-energy protons is a very effective method of cancer treatment. To attain the necessary beam energy for cancer therapy using a very compact synchrotron, the magnetic field of the normal-conductive bending magnet must be excited up to 3-5 T. However, increasing the field up to 4 T produces a sextupole component in the field. The sextupole component can be reduced by changing the geometry of the coil, but establishing the optimal geometry is very time-consuming. A new optimization method has been developed to establish the uniform field in the bending magnet. As a result, the optimal geometry is obtained with less calculation time. (author)

  17. Non-stationary classical diffusion in field - reversed configurations

    International Nuclear Information System (INIS)

    Clemente, R.A.; Sakanaka, P.H.; Mania, A.J.

    1988-01-01

    Plasma decay in field-reversed configurations (FRC) is described using resistive MHD equations. Assuming non-stationariety together with uniform but time dependent plasma temperature and neglecting inertial effects in the momentum balance equation, it is possible to show that the functional dependence of the plasma pressure with the poloidal magnetic flux remains fixed during diffusion. This allows to describe FRC evolution as a continuous sequence of plasma equilibria satisfying proper boundary conditions. The method is applied to pressure profiles linear with the poloidal magnetic flux obtaining the evolution of the flux, the number of confined particles and the size of the plasma boundary. (author) [pt

  18. The effect of non-uniform fuel rod temperatures on effective resonance integrals

    International Nuclear Information System (INIS)

    Reichel, A.

    1961-06-01

    The effective resonance integral for heterogeneous lattices can be reduced to the effective resonance integral for an equivalent homogeneous system with a fairly well defined error depending on lump size and geometry. This report investigates the effect of a radial parabolic temperature variation in cylindrical lumps on the equivalent homogeneous effective resonance integral. Also determined is the equivalent uniform temperature to be taken in the usual formulae to allow for non-uniform fuel rod temperature. This effective temperature is found to be T eff. = T s + 4/9 (T c - T s ) where T s and T c are the surface and central temperatures of the lump. (author)

  19. Linac-based isocentric electron-photon treatment of radically operated breast carcinoma with enhanced dose uniformity in the field gap area.

    Science.gov (United States)

    Tenhunen, Mikko; Nyman, Heidi; Strengell, Satu; Vaalavirta, Leila

    2009-10-01

    Isocentric treatment technique is a standard method in photon radiotherapy with the primary advantage of requiring only a single patient set-up procedure for multiple fields. However, in electron treatments the size of the standard applicators does not generally allow to use an isocentric treatment technique. In this work we have modified and dosimetrically tested electron applicators for isocentric treatments in combination with photons. An isocentric treatment technique with photons and electrons for postmastectomy radiation therapy (PMRT) has been developed with special emphasis on improving the dose uniformity in the field gap area. Standard electron applicators of two Varian Clinac 2100CD linear accelerators were shortened by 10cm allowing isocentric treatments of 90cmelectron fields. Shortened applicators were commissioned and configured for the electron calculation algorithm of the treatment planning system. The field arrangement of PMRT was modified by combining three photon field segments with different gaps and overlaps with the electron field to improve dose uniformity. The developed technique and two other methods for PMRT were compared with each other in the group of 20 patients. Depth dose characteristics of the shortened applicators remained unchanged from those of the standard applicators. Penumbrae were broadened by 0-3mm depending on electron energy and depth as the air gap was increased from 5cm (standard applicator at SSD=100cm) to 10cm (shortened applicator at SSD=95cm). The dose calculation performance of the modified applicators at 95cmelectron dose calculation algorithm of the treatment planning system (Varian Eclipse). The modified isocentric treatment technique for PMRT was superior than the traditional two-dimensional technique. However, with the tangential photon fields without electrons the even better dose uniformity within PTV could be achieved but with increased irradiation of healthy tissues (lung, heart, and contralateral breast

  20. Non-Uniform Heat Transfer in Thermal Regenerators

    DEFF Research Database (Denmark)

    Jensen, Jesper Buch

    , a numerical model, which simulates a single-blow operation in a parallel-plate regenerator, was developed and used to model the heat transfer under various conditions. In addition to the modeling of the heat transfer, a series of experiments on passive regenerators with non-uniform, but precisely controlled....... Additionally, the experiments gave real comparative results, whereas the model to a certain degree more served to provide insight to the heat transfer processes taking place inside the regenera- tors, something that would be - if not impossible - then highly impractical to do experimentally. It has been found......This thesis presents investigations on the heat transfer in complex heat ex- changers in general and in regenerative heat exchangers (regenerators) in par- ticular. The motivation for this work is a result of inconsistencies obeserved in the results from a series of experiments on active magnetic...

  1. Determination of the axial thermal neutron flux non-uniform factor in the MNSR inner irradiation capsule

    International Nuclear Information System (INIS)

    Khattab, K.; Ghazi, N.; Omar, H.

    2007-01-01

    A 3-D neutronic model, using the WIMSD4 and CITATION codes, for the Syrian Miniature Neutron source Reactor (MNSR) is used to calculate the axial thermal neutron flux non-uniform factor in the inner irradiation capsule. The calculated result is 4%. A copper wire is used to measure the axial thermal neutron flux non-uniform factor in the inner irradiation capsule to be compared with the calculated result. The measured result is 5%. Good agreement between the measured and calculated results is obtained. (author)

  2. Determination of the axial thermal neutron flux non-uniform factor in the MNSR inner irradiation capsule

    International Nuclear Information System (INIS)

    Khattab, K.; Ghazi, N.; Omar, H.

    2007-01-01

    A 3-D neutronic model, using the WIMSD4 and CITATION codes, for the Syrian Miniature Neutron Source Reactor (MNSR) is used to calculate the axial thermal neutron flux non-uniform factor in the inner irradiation capsule. The calculated result is 4%. A copper wire is used to measure the axial thermal neutron flux non-uniform factor in the inner irradiation capsule to be compared with the calculated result. The measured result is 5%. Good agreement between the measured and calculated results is obtained

  3. Weed control based on real time patchy application of herbicides using image analysis as a non-destructive estimation method for weed infestation and herbicide effects

    DEFF Research Database (Denmark)

    Asif, Ali

    There is an increasing concern about excessive use of herbicides for weed control in arable lands. Usually the whole field is sprayed uniformly, while the distribution of weeds often is non-uniform. Often there are spots in a field where weed pressure is very low and has no significant effect...... on crop yield. The excessive use of spraying can potentially be reduced by spraying only those parts of the field where it has economic importance. The competition relation between weeds and crop was ana-lyzed in context of real time patch spray. A non-destructive image analysis method was developed...

  4. Non-Destructive Monitoring of Charge-Discharge Cycles on Lithium Ion Batteries using 7Li Stray-Field Imaging

    Science.gov (United States)

    Tang, Joel A.; Dugar, Sneha; Zhong, Guiming; Dalal, Naresh S.; Zheng, Jim P.; Yang, Yong; Fu, Riqiang

    2013-01-01

    Magnetic resonance imaging provides a noninvasive method for in situ monitoring of electrochemical processes involved in charge/discharge cycling of batteries. Determining how the electrochemical processes become irreversible, ultimately resulting in degraded battery performance, will aid in developing new battery materials and designing better batteries. Here we introduce the use of an alternative in situ diagnostic tool to monitor the electrochemical processes. Utilizing a very large field-gradient in the fringe field of a magnet, stray-field-imaging (STRAFI) technique significantly improves the image resolution. These STRAFI images enable the real time monitoring of the electrodes at a micron level. It is demonstrated by two prototype half-cells, graphite∥Li and LiFePO4∥Li, that the high-resolution 7Li STRAFI profiles allow one to visualize in situ Li-ions transfer between the electrodes during charge/discharge cyclings as well as the formation and changes of irreversible microstructures of the Li components, and particularly reveal a non-uniform Li-ion distribution in the graphite. PMID:24005580

  5. Phase transitions in local equation-of-state approximation and anomalies of spatial charge profiles in non-uniform plasma

    Science.gov (United States)

    Chigvintsev, A. Yu; Zorina, I. G.; Noginova, L. Yu; Iosilevskiy, I. L.

    2018-01-01

    Impressive appearance of discontinuities in equilibrium spatial charge profiles in non-uniform Coulomb systems is under discussions in wide number of thermoelectrostatics problems. Such discontinuities are considered as peculiar micro-level manifestation of phase transitions and intrinsic macro-level non-ideality effects in local equation of state (EOS), which should be used for description of non-ideal ionic subsystem in frames of local-density (or “pseudofluid”, or “jellium” etc) approximation. Such discontinuities were discussed already by the authors for electronic subsystems. Special emphasis is made in present paper on the mentioned above non-ideality effects in non-uniform ionic subsystems, such as micro-ions profile within screening “cloud” around macro-ion in complex (dusty, colloid etc) plasmas, equilibrium charge profile in ionic traps or (and) in the neighborhood vicinity of “charged wall” etc). Multiphase EOS for simplified ionic model of classical charged hard spheres on uniformly compressible electrostatic compensating background was constructed and several illustrative examples of discussed discontinuous ionic profiles were calculated.

  6. Quantum ratchet effect in a time non-uniform double-kicked model

    Science.gov (United States)

    Chen, Lei; Wang, Zhen-Yu; Hui, Wu; Chu, Cheng-Yu; Chai, Ji-Min; Xiao, Jin; Zhao, Yu; Ma, Jin-Xiang

    2017-07-01

    The quantum ratchet effect means that the directed transport emerges in a quantum system without a net force. The delta-kicked model is a quantum Hamiltonian model for the quantum ratchet effect. This paper investigates the quantum ratchet effect based on a time non-uniform double-kicked model, in which two flashing potentials alternately act on a particle with a homogeneous initial state of zero momentum, while the intervals between adjacent actions are not equal. The evolution equation of the state of the particle is derived from its Schrödinger equation, and the numerical method to solve the evolution equation is pointed out. The results show that quantum resonances can induce the ratchet effect in this time non-uniform double-kicked model under certain conditions; some quantum resonances, which cannot induce the ratchet effect in previous models, can induce the ratchet effect in this model, and the strengths of the ratchet effect in this model are stronger than those in previous models under certain conditions. These results enrich people’s understanding of the delta-kicked model, and provides a new optional scheme to control the quantum transport of cold atoms in experiment.

  7. Theoretical study of a weakly ionised gas in a uniform constant electric field

    International Nuclear Information System (INIS)

    Segur, Pierre.

    1974-01-01

    The collision operators of the Boltzmann equation are expressed in terms of the transition probabilities for a Lorentz gas and inelastic type collisions in the case of conservation and non-conservation of the initial number of particles. These operators are approximately expressed when the mass ratio of the present particles is weak. The expressions obtained are valid for any particle distribution functions. A series expansion in spherical harmonics is effected for these operators. The Boltzmann equation is then solved for the case of a steady homogeneous medium when the electric field effect is lower than that of collisions. A resolving method is then proposed for the case where the electric field and collisions play comparable roles. Analytical expressions are given for the distribution functions in terms of asymptotic solutions valid for any type of cross section. A steady heterogenous medium is then studied by a direct numerical solution of the Boltzmann equation, for high values of the electric field/ pressure ratio. The existence of a single lattice of characteristic directions is established as well as a distribution function representing in phase space a band structure characteristic of the presence of inelastic collisions. The electron motion is simulated using a Monte-Carlo method. The calculations being effected in helium, a bibliography of the cross sections for this gas is given [fr

  8. Postbuckling of magneto-electro-elastic CNT-MT composite nanotubes resting on a nonlinear elastic medium in a non-uniform thermal environment

    Science.gov (United States)

    Kamali, M.; Shamsi, M.; Saidi, A. R.

    2018-03-01

    As a first endeavor, the effect of nonlinear elastic foundation on the postbuckling behavior of smart magneto-electro-elastic (MEE) composite nanotubes is investigated. The composite nanotube is affected by a non-uniform thermal environment. A typical MEE composite nanotube consists of microtubules (MTs) and carbon nanotubes (CNTs) with a MEE cylindrical nanoshell for smart control. It is assumed that the nanoscale layers of the system are coupled by a polymer matrix or filament network depending on the application. In addition to thermal loads, magneto-electro-mechanical loads are applied to the composite nanostructure. Length scale effects are taken into account using the nonlocal elasticity theory. The principle of virtual work and von Karman's relations are used to derive the nonlinear governing differential equations of MEE CNT-MT nanotubes. Using Galerkin's method, nonlinear critical buckling loads are determined. Various types of non-uniform temperature distribution in the radial direction are considered. Finally, the effects of various parameters such as the nonlinear constant of elastic medium, thermal loading factor and small scale coefficient on the postbuckling of MEE CNT-MT nanotubes are studied.

  9. Rough Sets and Stomped Normal Distribution for Simultaneous Segmentation and Bias Field Correction in Brain MR Images.

    Science.gov (United States)

    Banerjee, Abhirup; Maji, Pradipta

    2015-12-01

    The segmentation of brain MR images into different tissue classes is an important task for automatic image analysis technique, particularly due to the presence of intensity inhomogeneity artifact in MR images. In this regard, this paper presents a novel approach for simultaneous segmentation and bias field correction in brain MR images. It integrates judiciously the concept of rough sets and the merit of a novel probability distribution, called stomped normal (SN) distribution. The intensity distribution of a tissue class is represented by SN distribution, where each tissue class consists of a crisp lower approximation and a probabilistic boundary region. The intensity distribution of brain MR image is modeled as a mixture of finite number of SN distributions and one uniform distribution. The proposed method incorporates both the expectation-maximization and hidden Markov random field frameworks to provide an accurate and robust segmentation. The performance of the proposed approach, along with a comparison with related methods, is demonstrated on a set of synthetic and real brain MR images for different bias fields and noise levels.

  10. Comparison between 3D conventional techniques, field-in-field and electronic tissue compensation for mantle fields planning

    International Nuclear Information System (INIS)

    Martins, Lais P.; Silva, Leonardo P.; Trindade, Cassia; Garcia, Paulo L.; Santos, Maira R.; Batista, Delano V.S.

    2012-01-01

    External radiotherapy treatment for Hodgkin's lymphoma over diaphragm region requires large radiation fields with protections applied to larynx, humerus head and lungs. The size and shape of the field, which covers different depths, make it difficult to distribute a homogeneous dose. Techniques such as field-in-field and electronic tissue compensation may be used to make dose homogeneous and compensate the obliquity from the tissue. Three types of planning were performed for diagnose of nodular sclerosis Hodgkin's lymphoma: one plan with two fields, AP-PA (AP plan), another with four fields field-in- field (FF plan), and a third one with two fields and electronic tissue compensation (ETC plan). Results showed better gradient, cover of PTV and dose distribution for the ETC plan, besides the advantage from this technique of does not require protection blocks. In the meanwhile, AP and FF plans require simpler dosimetry and fewer MU. Related to the uniformity of dose distribution, AP plan showed hot areas in the neck region, FF plan showed hot areas in the shoulder region and ETC plan showed most uniform distribution without hot areas. The electronic tissue compensation is a useful tool for large and shaped fields as the mantle field, however higher MU and complex dosimetry should be taken in account. (author)

  11. Isocentric integration of intensity-modulated radiotherapy with electron fields improves field junction dose uniformity in postmastectomy radiotherapy.

    Science.gov (United States)

    Wright, Pauliina; Suilamo, Sami; Lindholm, Paula; Kulmala, Jarmo

    2014-08-01

    In postmastectomy radiotherapy (PMRT), the dose coverage of the planning target volume (PTV) with additional margins, including the chest wall, supraclavicular, interpectoral, internal mammary and axillar level I-III lymph nodes, is often compromised. Electron fields may improve the medial dose coverage while maintaining organ at risk (OAR) doses at an acceptable level, but at the cost of hot and cold spots at the electron and photon field junction. To improve PMRT dose coverage and uniformity, an isocentric technique combining tangential intensity-modulated (IM)RT fields with one medial electron field was implemented. For 10 postmastectomy patients isocentric IMRT with electron plans were created and compared with a standard electron/photon mix and a standard tangent technique. PTV dose uniformity was evaluated based on the tolerance range (TR), i.e. the ratio of the standard deviation to the mean dose, a dice similarity coefficient (DSC) and the 90% isodose coverage and the hot spot volumes. OAR and contralateral breast doses were also recorded. IMRT with electrons significantly improved the PTV dose homogeneity and conformity based on the TR and DSC values when compared with the standard electron/photon and tangent technique (p < 0.02). The 90% isodose coverage improved to 86% compared with 82% and 80% for the standard techniques (p < 0.02). Compared with the standard electron/photon mix, IMRT smoothed the dose gradient in the electron and photon field junction and the volumes receiving a dose of 110% or more were reduced by a third. For all three strategies, the OAR and contralateral breast doses were within clinically tolerable limits. Based on these results two-field IMRT combined with an electron field is a suitable strategy for PMRT.

  12. Research on non-uniform strain profile reconstruction along fiber Bragg grating via genetic programming algorithm and interrelated experimental verification

    Science.gov (United States)

    Zheng, Shijie; Zhang, Nan; Xia, Yanjun; Wang, Hongtao

    2014-03-01

    A new heuristic strategy for the non-uniform strain profile reconstruction along Fiber Bragg Gratings is proposed in this paper, which is based on the modified transfer matrix and Genetic Programming(GP) algorithm. The present method uses Genetic Programming to determine the applied strain field as a function of position along the fiber length. The structures that undergo adaptation in genetic programming are hierarchical structures which are different from that of conventional genetic algorithm operating on strings. GP regress the strain profile function which matches the 'measured' spectrum best and makes space resolution of strain reconstruction arbitrarily high, or even infinite. This paper also presents an experimental verification of the reconstruction of non-homogeneous strain fields using GP. The results are compared with numerical calculations of finite element method. Both the simulation examples and experimental results demonstrate that Genetic Programming can effectively reconstruct continuous profile expression along the whole FBG, and greatly improves its computational efficiency and accuracy.

  13. Efficient design of multiplier-less digital channelizers using recombination non-uniform filter banks

    Directory of Open Access Journals (Sweden)

    Shaeen Kalathil

    2018-01-01

    Full Text Available A novel approach for the efficient realization of digital channelizers in software defined radios using recombination filter banks is proposed in this paper. Digital channelizer is the core of software defined radio. Computationally efficient design supporting multiple channels with different bandwidths and low complexity are inevitable requirements for the digital channelizers. Recombination filter banks method is used to obtain non-uniform filter banks with rational sampling factors, using a two stage structure. It consists of a uniform filter bank and trans-multiplexer. In this work, the uniform filter bank and trans-multiplexer are designed using cosine modulated filter banks. The prototype filter design is made simple, efficient and fast, using window method. The multiplier-less realization of recombination filter banks in the canonic signed digit space using nature inspired optimization algorithms, results in reduced implementation complexity.

  14. Effect of disjoining pressure in a thin film equation with non-uniform forcing

    KAUST Repository

    MOULTON, D. E.; LEGA, J.

    2013-01-01

    We explore the effect of disjoining pressure on a thin film equation in the presence of a non-uniform body force, motivated by a model describing the reverse draining of a magnetic film. To this end, we use a combination of numerical investigations

  15. Electrorotation of novel electroactive polymer composites in uniform DC and AC electric fields

    International Nuclear Information System (INIS)

    Zrinyi, Miklós; Nakano, Masami; Tsujita, Teppei

    2012-01-01

    Novel electroactive polymer composites have been developed that could spin in uniform DC and AC electric fields. The angular displacement as well as rotation of polymer disks around an axis that is perpendicular to the direction of the applied electric field was studied. It was found that the dynamics of the polymer rotor is very complex. Depending on the strength of the static DC field, three regimes have been observed: no rotation occurs below a critical threshold field intensity, oscillatory motion takes place just above this value and continuous rotation can be observed above the critical threshold field intensity. It was also found that low frequency AC fields could also induce angular deformation. (paper)

  16. Orbits of two electrons released from rest in a uniform transverse magnetic field

    Science.gov (United States)

    Mungan, Carl E.

    2018-03-01

    Two identical charged particles released from rest repel each other radially. A uniform perpendicular magnetic field will then cause their trajectories to curve into a flower petal pattern. The orbit of each particle is approximately circular with a long period for a strong magnetic field, whereas it becomes a figure-eight for a weak magnetic field with each lobe completed in a cyclotron period. For example, such radially bound motions arise for two-dimensional electron gases. The level of treatment is appropriate for an undergraduate calculus-based electromagnetism course.

  17. The influence of printing substrate on macro non-uniformity and line reproduction quality of imprints printed with electrophotographic process

    Directory of Open Access Journals (Sweden)

    Đorđe Vujčić

    2016-12-01

    Full Text Available Print quality is very important for every printing technique. It depends on many different quality attributes. This research included analysis of macro non-uniformities and line reproduction. 16 different paper substrates printed by electrophotographic process were analyzed. They were separated in two groups: coated and uncoated papers. Analysis of macro non-uniformity showed that print mottle has lower values when printed on coated papers than on uncoated papers. Line reproduction analysis showed that the toner spreaded, during melting and fixation, on line edges for both types of paper. According to these results it can be concluded that paper substrate affects the macro non-uniformity and line reproduction, thus overall print quality.

  18. Correspondence between classical and quantum chaos for hydrogen in a uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Harada, A; Hasegawa, H [Kyoto Univ. (Japan). Dept. of Physics

    1983-06-01

    It is shown, by numerical computations, that the classical and the quantal critical energy of a hydrogen atom in a uniform magnetic field, characterising the onset of irregular motions, approximately coincide. This result is obtained by applying a simple scaling property of the classical Hamiltonian, valid only for Lsub(z)=O (the angular momentum component along the field vanishes), to the numerically deduced relative areas of the irregular region of Poincare surfaces of section.

  19. Electric field computation and measurements in the electroporation of inhomogeneous samples

    Science.gov (United States)

    Bernardis, Alessia; Bullo, Marco; Campana, Luca Giovanni; Di Barba, Paolo; Dughiero, Fabrizio; Forzan, Michele; Mognaschi, Maria Evelina; Sgarbossa, Paolo; Sieni, Elisabetta

    2017-12-01

    In clinical treatments of a class of tumors, e.g. skin tumors, the drug uptake of tumor tissue is helped by means of a pulsed electric field, which permeabilizes the cell membranes. This technique, which is called electroporation, exploits the conductivity of the tissues: however, the tumor tissue could be characterized by inhomogeneous areas, eventually causing a non-uniform distribution of current. In this paper, the authors propose a field model to predict the effect of tissue inhomogeneity, which can affect the current density distribution. In particular, finite-element simulations, considering non-linear conductivity against field relationship, are developed. Measurements on a set of samples subject to controlled inhomogeneity make it possible to assess the numerical model in view of identifying the equivalent resistance between pairs of electrodes.

  20. A study on liquid lithium flow in rectangular duck perpendicular to a intense magnetic field

    International Nuclear Information System (INIS)

    Shen Xiuzhong; Chen Ke; Liu Yang; Zhang Qinshun

    2001-01-01

    A research on high-speed liquid-metal lithium flow through a non-expanding rectangular duck under uniform intense magnetic field is presented. A equations set with Poisson equation and Helmholtz equation, which control the electrical field and flow field respectively, has been deduced by analysis and PHsolver, a program to solve the equations set, has also been finished. The current density distribution and flow field in the non-expanding rectangular channel with intense magnetic field have been obtained from PHsolver by applying the wall-function in the boundary wall. The velocity profile in the duck appears M-shaped

  1. Research of non-uniform multiple hole straighteners for measuring flow rate

    International Nuclear Information System (INIS)

    Wen Duanzhong; Zhong Dezhen; Cai Zhuti

    1989-01-01

    Standard throttling flowmeters are widely used in process flow rate measurement. Enough upstream and downstream straight pipe are necessary for it. If not, the error will be increased. Mounting straightener is an effective way for solving this problem. Advantages of non-uniform multiple hole straighteners studied by authors are good results for straighting, simple in Structure, convenient for mounting and low cost. So it can be popularized in many applications

  2. Impulse breakdown of small air gap in electric field Part II: Statistical ...

    African Journals Online (AJOL)

    The patterns of shot distribution and maximum coverage at impulse breakdown voltage for positive point electr-odes (needle and cone electrodes) in small air gaps in non-uniform electric fields were investigated. During the breakdown test, a sheet of paper was placed on the plate electrode (-ve), and each breakdown shot ...

  3. Weyl geometry and the nonlinear mechanics of distributed point defects

    KAUST Repository

    Yavari, A.

    2012-09-05

    The residual stress field of a nonlinear elastic solid with a spherically symmetric distribution of point defects is obtained explicitly using methods from differential geometry. The material manifold of a solid with distributed point defects-where the body is stress-free-is a flat Weyl manifold, i.e. a manifold with an affine connection that has non-metricity with vanishing traceless part, but both its torsion and curvature tensors vanish. Given a spherically symmetric point defect distribution, we construct its Weyl material manifold using the method of Cartan\\'s moving frames. Having the material manifold, the anelasticity problem is transformed to a nonlinear elasticity problem and reduces the problem of computing the residual stresses to finding an embedding into the Euclidean ambient space. In the case of incompressible neo-Hookean solids, we calculate explicitly this residual stress field. We consider the example of a finite ball and a point defect distribution uniform in a smaller ball and vanishing elsewhere. We show that the residual stress field inside the smaller ball is uniform and hydrostatic. We also prove a nonlinear analogue of Eshelby\\'s celebrated inclusion problem for a spherical inclusion in an isotropic incompressible nonlinear solid. © 2012 The Royal Society.

  4. Electric field of not completely symmetric systems earthed sphere-uniformly charged dielectric plan

    International Nuclear Information System (INIS)

    Vila, F.

    1994-07-01

    In this paper we study theoretically the electric field in the not completely symmetric system, earthed metallic sphere-uniformly charged dielectric plan, for sphere surface points situated in the plan that contains sphere's center and vertical symmetry axe of dielectric plan. (author). 11 refs, 1 fig

  5. On the Time Variation of Dust Extinction and Gas Absorption for Type Ia Supernovae Observed Through Non-uniform Interstellar Medium

    Science.gov (United States)

    Huang, Xiaosheng; Aldering, Gregory; Biederman, Moriah; Herger, Brendan

    2018-01-01

    For Type Ia supernovae (SNe Ia) observed through a non-uniform interstellar medium (ISM) in its host galaxy, we investigate whether the non-uniformity can cause observable time variations in dust extinction and in gas absorption due to the expansion of the SN photosphere with time. We show that, owing to the steep spectral index of the ISM density power spectrum, sizable density fluctuation amplitudes at the length scale of typical ISM structures (>~ 10 pc) will translate to much smaller fluctuations on the scales of a SN photosphere. Therefore the typical amplitude of time variation due to non-uniform ISM, of absorption equivalent widths and of extinction, would be small. As a result, we conclude that non-uniform ISM density should not impact cosmology measurements based on SNe Ia. We apply our predictions based on the ISM density power law power spectrum to the observations of two highly reddened SNe Ia, SN 2012cu and SN 2014J.

  6. Age-dependent effective doses for radionuclides uniformly distributed in air

    International Nuclear Information System (INIS)

    Hung, Tran Van

    2014-01-01

    Age-dependent effective doses for external exposure to photons emitted by radionuclides uniformly distributed in air are reported. The calculations were performed for 160 radionuclides, which are important for safety assessment of nuclear facilities. The energies and intensities of photons emitted from radionuclides were taken from the decay data DECDC used for dose calculations. The results are tabulated in the form of effective dose per unit concentration and time (Sv per Bq s m -3 ) for 6 age groups: newborn, 1, 5, 10 and 15 years-old and adult. The effective doses for the adult are also compared to values given in the literature.

  7. Nonlinear Spinor Field in Non-Diagonal Bianchi Type Space-Time

    Directory of Open Access Journals (Sweden)

    Saha Bijan

    2018-01-01

    Full Text Available Within the scope of the non-diagonal Bianchi cosmological models we have studied the role of the spinor field in the evolution of the Universe. In the non-diagonal Bianchi models the spinor field distribution along the main axis is anisotropic and does not vanish in the absence of the spinor field nonlinearity. Hence within these models perfect fluid, dark energy etc. cannot be simulated by the spinor field nonlinearity. The equation for volume scale V in the case of non-diagonal Bianchi models contains a term with first derivative of V explicitly and does not allow exact solution by quadratures. Like the diagonal models the non-diagonal Bianchi space-time becomes locally rotationally symmetric even in the presence of a spinor field. It was found that depending on the sign of the coupling constant the model allows either an open Universe that rapidly grows up or a close Universe that ends in a Big Crunch singularity.

  8. Validation of a non-uniform meshing algorithm for the 3D-FDTD method by means of a two-wire crosstalk experimental set-up

    Directory of Open Access Journals (Sweden)

    Raúl Esteban Jiménez-Mejía

    2015-06-01

    Full Text Available This paper presents an algorithm used to automatically mesh a 3D computational domain in order to solve electromagnetic interaction scenarios by means of the Finite-Difference Time-Domain -FDTD-  Method. The proposed algorithm has been formulated in a general mathematical form, where convenient spacing functions can be defined for the problem space discretization, allowing the inclusion of small sized objects in the FDTD method and the calculation of detailed variations of the electromagnetic field at specified regions of the computation domain. The results obtained by using the FDTD method with the proposed algorithm have been contrasted not only with a typical uniform mesh algorithm, but also with experimental measurements for a two-wire crosstalk set-up, leading to excellent agreement between theoretical and experimental waveforms. A discussion about the advantages of the non-uniform mesh over the uniform one is also presented.

  9. Numerical Prediction of the Impact of Non-Uniform Leading Edge Coatings On the Aerodynamic Performance of Compressor Airfoils

    National Research Council Canada - National Science Library

    Elmstrom, Michael

    2004-01-01

    A computational fluid dynamic (CFD) investigation is presented that provides predictions of the aerodynamic impact of uniform and non-uniform coatings applied to the leading edge of a compressor airfoil in a cascade. Using a NACA 65(12...

  10. Three-dimensional magnetic field computation on a distributed memory parallel processor

    International Nuclear Information System (INIS)

    Barion, M.L.

    1990-01-01

    The analysis of three-dimensional magnetic fields by finite element methods frequently proves too onerous a task for the computing resource on which it is attempted. When non-linear and transient effects are included, it may become impossible to calculate the field distribution to sufficient resolution. One approach to this problem is to exploit the natural parallelism in the finite element method via parallel processing. This paper reports on an implementation of a finite element code for non-linear three-dimensional low-frequency magnetic field calculation on Intel's iPSC/2

  11. RF Magnetic Field Uniformity of Rectangular Planar Coils for Resonance Imaging

    Science.gov (United States)

    2016-02-04

    magnetic, potassium chlorate , nuclear quadrupole resonance, uniform field, coil, surface coil I. INTRODUCTION QR is a magnetic resonance phenomenon...material that will be used is this investigation is potassium chlorate (KCLO3). This paper utilizes the NQR signals detection from KCLO3 to determine the...frequency of potassium chlorate (KCLO3), and matched to a 50 ohm input impedance using L-network circuit of capacitors. Fig.1 shows a diagram of the

  12. Pondermotive absorption of a short intense laser pulse in a non-uniform plasma

    Energy Technology Data Exchange (ETDEWEB)

    Andreev, A A; Platonov, K Yu [Inst. for Laser Physics, SC ` Vavilov State Optical Inst.` 12, Birzhevaya line, St Petersburg (Russian Federation); Tanaka, K A

    1998-03-01

    An analytical description of the pondermotive absorption mechanism at a short high intense laser pulse interaction with a strong inhomogeneous plasma is presented. The optimal conditions for the maximum of resonance absorption of laser pulse interaction with non-uniform plasma at normal incidence are founded. (author)

  13. Investigating the impact of visuohaptic simulations for the conceptual understanding of electric field for distributed charges

    Science.gov (United States)

    Shaikh, Uzma Abdul Sattar

    The present study assessed the benefits of a multisensory intervention on the conceptual understanding of electric field for distributed charges in engineering and technology undergraduate students. A novel visuohaptic intervention was proposed, which focused on exploring the forces around the different electric field configurations for distributed charges namely point, infinitely long line and uniformly charged ring. The before and after effects of the visuohaptic intervention are compared, wherein the intervention includes instructional scaffolding. Three single-group studies were conducted to investigate the effect among three different populations: (a) Undergraduate engineering students, (b) Undergraduate technology students and (c) Undergraduate engineering technology students from a different demographic setting. The findings from the three studies suggests that the haptic modality intervention provides beneficial effects by allowing students to improve their conceptual understanding of electric field for distributed charges, although students from groups (b) and (c) showed a statistically significant increase in the conceptual understanding. The findings also indicate a positive learning perception among all the three groups.

  14. Irregular wave functions of a hydrogen atom in a uniform magnetic field

    Science.gov (United States)

    Wintgen, D.; Hoenig, A.

    1989-01-01

    The highly excited irregular wave functions of a hydrogen atom in a uniform magnetic field are investigated analytically, with wave function scarring by periodic orbits considered quantitatively. The results obtained confirm that the contributions of closed classical orbits to the spatial wave functions vanish in the semiclassical limit. Their disappearance, however, is slow. This discussion is illustrated by numerical examples.

  15. Radiation flaw detector for testing non-uniform surface bodies of revolution

    International Nuclear Information System (INIS)

    Valevich, M.I.

    1984-01-01

    Radiation flaw detector for testing bodies of revolution with non-uniform surface, welded joints, etc., based on spatial filtration and differentiation of ionizing radiation flux has been described. The calculation of the most important unit of flaw detector - integrators - is made. Experimental studies of the sensitivity have shown, that the radiation flaw detector can be used for rapid testing of products with the sensitivity comparable with the sensitivity of radiographic testing of steel

  16. Circuit-field coupled finite element analysis method for an electromagnetic acoustic transducer under pulsed voltage excitation

    International Nuclear Information System (INIS)

    Hao Kuan-Sheng; Huang Song-Ling; Zhao Wei; Wang Shen

    2011-01-01

    This paper presents an analytical method for electromagnetic acoustic transducers (EMATs) under voltage excitation and considers the non-uniform distribution of the biased magnetic field. A complete model of EMATs including the non-uniform biased magnetic field, a pulsed eddy current field and the acoustic field is built up. The pulsed voltage excitation is transformed to the frequency domain by fast Fourier transformation (FFT). In terms of the time harmonic field equations of the EMAT system, the impedances of the coils under different frequencies are calculated according to the circuit-field coupling method and Poynting's theorem. Then the currents under different frequencies are calculated according to Ohm's law and the pulsed current excitation is obtained by inverse fast Fourier transformation (IFFT). Lastly, the sequentially coupled finite element method (FEM) is used to calculate the Lorentz force in the EMATs under the current excitation. An actual EMAT with a two-layer two-bundle printed circuit board (PCB) coil, a rectangular permanent magnet and an aluminium specimen is analysed. The coil impedances and the pulsed current are calculated and compared with the experimental results. Their agreement verified the validity of the proposed method. Furthermore, the influences of lift-off distances and the non-uniform static magnetic field on the Lorentz force under pulsed voltage excitation are studied. (interdisciplinary physics and related areas of science and technology)

  17. Integration of non-Gaussian fields

    DEFF Research Database (Denmark)

    Ditlevsen, Ove Dalager; Mohr, Gunnar; Hoffmeyer, Pernille

    1996-01-01

    The limitations of the validity of the central limit theorem argument as applied to definite integrals of non-Gaussian random fields are empirically explored by way of examples. The purpose is to investigate in specific cases whether the asymptotic convergence to the Gaussian distribution is fast....... and Randrup-Thomsen, S. Reliability of silo ring under lognormal stochastic pressure using stochastic interpolation. Proc. IUTAM Symp., Probabilistic Structural Mechanics: Advances in Structural Reliability Methods, San Antonio, TX, USA, June 1993 (eds.: P. D. Spanos & Y.-T. Wu) pp. 134-162. Springer, Berlin...

  18. SU-F-E-03: PET/CT Guided Dose Boost to Hypoxic Sub-Volume in Nasopharyngeal Carcinomas Using Self-Optimizing Non-Uniform VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, J; Zheng, X; Liu, H; Chen, B; Zhuo, W [FuDan University HuaDong Hospital, Institute of Radiation Medicine Fudan University Shanghai, Shanghai (China)

    2016-06-15

    Purpose: This study is to evaluate the feasibility of simultaneously integrated boost (SIB) to hypoxic subvolume (HTV) in nasopharyngeal carcinomas under the guidance of 18F-Fluoromisonidazole (FMISO) PET/CT using a novel non-uniform volumetric modulated arc therapy (VMAT)technique. Methods: Eight nasopharyngeal carcinoma patients treated with conventional uniform VMAT were retrospectively analyzed. For each treatment, actual conventional uniform VMAT plan with two or more arcs (2–2.5 arcs, totally rotating angle < 1000o) was designed with dose boost to hopxic subvolume (total dose, 84Gy) in the gross tumor volme (GTV) under the guidance of 18F- FMISO PET/CT. Based on the same dataset, experimental single arc non-uniform VAMT plans were generated with the same dose prescription using customized software tools. Dosimetric parameters, quality assurance and the efficiency of the treatment delivery were compared between the uniform and non-uniform VMAT plans. Results: To develop the non-uniform VMAT technique, a specific optimization model was successfully established. Both techniques generate high-quality plans with pass rate (>98%) with the 3mm, 3% criterion. HTV received dose of 84.1±0.75Gy and 84.1±1.2Gy from uniform and non-uniform VMAT plans, respectively. In terms of target coverage and dose homogeneity, there was no significant statistical difference between actual and experimental plans for each case. However, for critical organs at risk (OAR), including the parotids, oral cavity and larynx, dosimetric difference was significant with better dose sparing form experimental plans. Regarding plan implementation efficiency, the average machine time was 3.5 minutes for the actual VMAT plans and 3.7 minutes for the experimental nonuniform VMAT plans (p>0.050). Conclusion: Compared to conventional VMAT technique, the proposed non-uniform VMAT technique has the potential to produce efficient and safe treatment plans, especially in cases with complicated anatomical

  19. Patterned growth of carbon nanotubes over vertically aligned silicon nanowire bundles for achieving uniform field emission.

    Science.gov (United States)

    Hung, Yung-Jr; Huang, Yung-Jui; Chang, Hsuan-Chen; Lee, Kuei-Yi; Lee, San-Liang

    2014-01-01

    A fabrication strategy is proposed to enable precise coverage of as-grown carbon nanotube (CNT) mats atop vertically aligned silicon nanowire (VA-SiNW) bundles in order to realize a uniform bundle array of CNT-SiNW heterojunctions over a large sample area. No obvious electrical degradation of as-fabricated SiNWs is observed according to the measured current-voltage characteristic of a two-terminal single-nanowire device. Bundle arrangement of CNT-SiNW heterojunctions is optimized to relax the electrostatic screening effect and to maximize the field enhancement factor. As a result, superior field emission performance and relatively stable emission current over 12 h is obtained. A bright and uniform fluorescent radiation is observed from CNT-SiNW-based field emitters regardless of its bundle periodicity, verifying the existence of high-density and efficient field emitters on the proposed CNT-SiNW bundle arrays.

  20. Effect of scandia doping method on the emission uniformity of scandate cathode with Sc2O3–W matrix

    International Nuclear Information System (INIS)

    Wang, Jinshu; Lai, Chen; Liu, Wei; Yang, Fan; Zhang, Xizhu; Cui, Yuntao; Zhou, Meiling

    2013-01-01

    Graphical abstract: Emission uniformity of the cathodes prepared by mechanical mixing (a) and spray drying method (b). - Highlights: • The emission uniformity of scandate cathodes has been quantitively obtained. • The nanoparticles on the cathode surface lead to the electric field enhancement. • The cathode prepared by spray drying method exhibits good emission uniformity. - Abstract: Scandia doped tungsten matrix dispenser cathodes were manufactured using scandia doped tungsten powder prepared by mechanical mixing, liquid–solid doping and a spray drying method. It is found the macrostructure of the cathode depended on the powder preparation method. The cathode prepared using the powder prepared by spray drying method had a homogenous and porous matrix characterized with grains with a diameter of less than 1 μm and with many nanoparticles distributing uniformly around these grains. The cathode with submicron structure and uniform distribution of scandia exhibited good emission uniformity. The emission uniformity ΔJ/J of the cathode prepared by spray drying method was 0.17, about 6 times lower than that of the cathode prepared by mechanical mixing method. The calculation results showed that the nanoparticles led to electric field enhancement. A Ba–Sc–O multilayer on the cathode surface and nanoparticles distributing mainly on W grains contributed to the emission property of the cathode

  1. Effect of non-uniform Hall parameter on the electrode voltage drop in Faraday-type combustion MHD generators

    International Nuclear Information System (INIS)

    Gupta, G.P.; Rohatgi, V.K.

    1982-01-01

    Following a simplified approach, an expression is derived for the gas-dynamic voltage drop in a finitely segmented Faraday-type combustion MHD generator, taking into account the non-uniform Hall parameter across the channel. Combining the electrical sheath voltage drop, discussed briefly, with the gas-dynamic voltage drop, the effect of a non-uniform Hall parameter on the electrode voltage drop is studied using the theoretical and experimental input parameters of the Indian MHD channel test. The condition for the validity of the usual assumption of uniform Hall parameter across the channel is pointed out. Analysis of the measured electrode voltage drop predicts the real gas conductivity in the core to be in the range of 60 to 75 per cent of the theoretically calculated core conductivity. (author)

  2. On the Super-Turing Computational Power of Non-Uniform Families of Neuromata

    Czech Academy of Sciences Publication Activity Database

    Wiedermann, Jiří

    2002-01-01

    Roč. 12, č. 5 (2002), s. 509-516 ISSN 1210-0552. [SOFSEM 2002 Workshop on Soft Computing. Milovy, 28.11.2002-29.11.2002] R&D Projects: GA ČR GA201/00/1489 Institutional research plan: AV0Z1030915 Keywords : neuromata * Turing machines with advice * non-uniform computational complexity * super-Turing computational power Subject RIV: BA - General Mathematics

  3. Determination of the saturation magnetization, anisotropy field, mean field interaction, and switching field distribution for nanocrystalline hard magnets

    International Nuclear Information System (INIS)

    McCallum, R. William

    2005-01-01

    For a uniaxial nanocrystalline magnetic material, the determination of the saturation magnetization, M s , requires measurements of the magnetization at fields which exceed the anisotropy field. For a typical RE-Tm compound, where RE=rare earth and Tm=transition metal, this may require fields above 7 T if the approach to saturation law is used. However for an isotropic material composed of a random distribution of non-interacting uniaxial grains, both M s and the anisotropy filed, H a , may be determined by fitting the Stoner-Wohlfarth (SW) model (Philos. Trans. Roy. Soc. 240 (1948) 599) to the reversible part of the demagnetization curve in the first quadrant. Furthermore, using the mean field interaction model of Callen, Liu and Cullen [2], a quantitative measure of the interaction strength for interacting particles may be determined. In conjunction with an analytical fit to the first quadrant demagnetization curve of the SW model, this allows M s , H a and the mean field interaction constant of a nanocrystalline magnet to be determined from measurements below 5 T. Furthermore, comparison of the model solution for the reversible magnetization with experimental data in the 2nd and 3rd quadrants allows the accurate determination of the switching field distribution. In many cases the hysteresis loop may be accurately described by a normal distribution of switching fields

  4. Uniform Sampling Table Method and its Applications II--Evaluating the Uniform Sampling by Experiment.

    Science.gov (United States)

    Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei

    2015-01-01

    A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis.

  5. Comparison between 3D conventional techniques, field-in-field and electronic tissue compensation for mantle fields planning; Comparacao entre tecnica 3D convencional, field-in-field e compensacao eletronica para planejamento de manto

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Lais P.; Silva, Leonardo P.; Trindade, Cassia; Garcia, Paulo L.; Santos, Maira R.; Batista, Delano V.S., E-mail: pm.lais@gmail.com [Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ (Brazil)

    2012-12-15

    External radiotherapy treatment for Hodgkin's lymphoma over diaphragm region requires large radiation fields with protections applied to larynx, humerus head and lungs. The size and shape of the field, which covers different depths, make it difficult to distribute a homogeneous dose. Techniques such as field-in-field and electronic tissue compensation may be used to make dose homogeneous and compensate the obliquity from the tissue. Three types of planning were performed for diagnose of nodular sclerosis Hodgkin's lymphoma: one plan with two fields, AP-PA (AP plan), another with four fields field-in- field (FF plan), and a third one with two fields and electronic tissue compensation (ETC plan). Results showed better gradient, cover of PTV and dose distribution for the ETC plan, besides the advantage from this technique of does not require protection blocks. In the meanwhile, AP and FF plans require simpler dosimetry and fewer MU. Related to the uniformity of dose distribution, AP plan showed hot areas in the neck region, FF plan showed hot areas in the shoulder region and ETC plan showed most uniform distribution without hot areas. The electronic tissue compensation is a useful tool for large and shaped fields as the mantle field, however higher MU and complex dosimetry should be taken in account. (author)

  6. Energy Cascade from Internal Modes in Non-uniformly Stratified Fluid through Excitation of Superharmonic Disturbances

    Science.gov (United States)

    Sutherland, B. R.

    2016-02-01

    It is well established that two-dimensional internal plane waves and modes in uniformly stratified fluid efficiently transfer energy to smaller scale waves and ultimately turbulent mixing through parametric subharmonic instability (PSI). The numerical simulations of MacKinnon & Winters (GRL 2005) predicted PSI should act efficiently to disrupt the internal tide. However, while in situ observations showed the presence of PSI, it was not found to be appreciable. One reason for the discrepancy between simulations and observations is that the former examined an internal mode in uniformly stratified fluid whereas, in reality, the internal tide exists in non-uniform stratification and is manifest as sinusoidal oscillations of the thermocline. Through theory supported by numerical simulations, it is shown that internal modes in non-uniform stratification immediately excite superharmonics, not subharmonic disturbances. These have double the horizontal wavenumber and double the frequency of the parent mode and hence move with the same horizontal phase speed of the parent mode. As the disturbances grow in amplitude, however, they interact with the parent mode generating small-scale vertically propagating internal waves within the strongly stratified layer. The occurrence of PSI over very long times can occur, as in the simulations of Hazewinkel and Winters (JPO 2011). However, a comprehensive understanding of the energy cascade from the internal tide to small scales must consider the evolution of excited superharmonic disturbances.

  7. High-order non-uniform grid schemes for numerical simulation of hypersonic boundary-layer stability and transition

    International Nuclear Information System (INIS)

    Zhong Xiaolin; Tatineni, Mahidhar

    2003-01-01

    The direct numerical simulation of receptivity, instability and transition of hypersonic boundary layers requires high-order accurate schemes because lower-order schemes do not have an adequate accuracy level to compute the large range of time and length scales in such flow fields. The main limiting factor in the application of high-order schemes to practical boundary-layer flow problems is the numerical instability of high-order boundary closure schemes on the wall. This paper presents a family of high-order non-uniform grid finite difference schemes with stable boundary closures for the direct numerical simulation of hypersonic boundary-layer transition. By using an appropriate grid stretching, and clustering grid points near the boundary, high-order schemes with stable boundary closures can be obtained. The order of the schemes ranges from first-order at the lowest, to the global spectral collocation method at the highest. The accuracy and stability of the new high-order numerical schemes is tested by numerical simulations of the linear wave equation and two-dimensional incompressible flat plate boundary layer flows. The high-order non-uniform-grid schemes (up to the 11th-order) are subsequently applied for the simulation of the receptivity of a hypersonic boundary layer to free stream disturbances over a blunt leading edge. The steady and unsteady results show that the new high-order schemes are stable and are able to produce high accuracy for computations of the nonlinear two-dimensional Navier-Stokes equations for the wall bounded supersonic flow

  8. Evaluation of distribution coefficients for the prediction of strontium and cesium migration in a uniform sand

    International Nuclear Information System (INIS)

    Reynolds, W.D.; Gillham, R.W.; Cherry, J.A.

    1982-01-01

    The validity of using a distribution coefficient (Ksub(d)) in the mathematical prediction of strontium and cesium transport through uniform saturated sand was investigated by comparing measured breakthrough curves with curves of simulations using the advection-dispersion and the advection equations. Values for Ksub(d) were determined by batch equilibration tests and, indirectly, by fitting the mathematical model to breakthrough data from column experiments. Although the advection-dispersion equation accurately represented the breakthrough curves for two nonreactive solutes (chloride and tritium), neither it nor the advection equation provided close representations of the strontium and cesium curves. The simulated breakthrough curves for strontium and cesium were nearly symmetrical, whereas the data curves were very asymmetrical, with long tails. Column experiments with different pore-water velocities indicated that the shape of the normalized breakthrough curves was not sensitive to velocity. This suggests that the asymmetry of the measured curves was the result of nonlinear partitioning of the cations between the solid and liquid phases, rather than nonequilibrium effects. The results indicate that the distribution coefficient, when used in advection-dispersion models for prediction of the migration of strontium and cesium in field situations, can result in significant error

  9. Stress distributions of coils for toroidal magnetic field

    International Nuclear Information System (INIS)

    Kajita, Tateo; Miyamoto, Kenro.

    1976-01-01

    The stress distributions of a D shaped coil and a circular coil are computed by the finite element method. The dependences of the stress distribution on the geometrical parameters of the stress distribution on the geometrical parameters of the coils and supporting methods are examined. The maximum amount of the stress in the D shaped coil is not much smaller than that of the circular one. However, the stress distribution of the D shaped coil becomes much more uniform. The supporting method has as much effect as the geometrical parameters of the coil on the stress distribution. (auth.)

  10. Enhancement of quasi-static strain energy harvesters using non-uniform cross-section post-buckled beams

    Science.gov (United States)

    Jiao, Pengcheng; Borchani, Wassim; Hasni, Hassene; Lajnef, Nizar

    2017-08-01

    Thanks to their efficiency enhancement systems based on post-buckled structural elements have been extensively used in many applications such as actuation, remote sensing and energy harvesting. The post-buckling snap-through behavior of bilaterally constrained beams has been exploited to create sensing or energy harvesting mechanisms for quasi-static applications. The conversion mechanism has been used to transform low-rate and low-frequency excitations into high-rate motions. Electric energy has been generated from such high-rate motions using piezoelectric transducers. However, lack of control over the post-buckling behavior severely limits the mechanism’s efficiency. This study aims to maximize the levels of harvestable power by controlling the location of snap-throughs along the beam at different buckling transitions. Since the snap-through location cannot be controlled by tuning the geometric properties of a uniform beam, non-uniform cross-sections are examined. An energy-based theoretical model is herein developed to predict the post-buckling response of non-prismatic beams. The total potential energy is minimized under constraints that represent the physical confinement of the beam between the lateral boundaries. The experimentally validated results show that changing the shape and geometric dimensions of non-uniform beams allows for the accurate controlling of the snap-through location at different buckling transitions. A 78.59% improvement in harvested energy levels has been achieved by optimization of beam shape.

  11. Non-uniform plastic deformation of micron scale objects

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof; Hutchinson, J. W.

    2003-01-01

    Significant increases in apparent flow strength are observed when non-uniform plastic deformation of metals occurs at the scale ranging from roughly one to ten microns. Several basic plane strain problems are analyzed numerically in this paper based on a new formulation of strain gradient...... plasticity. The problems are the tangential and normal loading of a finite rectangular block of material bonded to rigid platens and having traction-free ends, and the normal loading of a half-space by a flat, rigid punch. The solutions illustrate fundamental features of plasticity at the micron scale...... that are not captured by conventional plasticity theory. These include the role of material length parameters in establishing the size dependence of strength and the elevation of resistance to plastic flow resulting from constraint on plastic flow at boundaries. Details of the finite element method employed...

  12. A Three-Dimensional Pore-Scale Model for Non-Wetting Phase Mobilization with Ferrofluid

    Science.gov (United States)

    Wang, N.; Prodanovic, M.

    2017-12-01

    Ferrofluid, a stable dispersion of paramagnetic nanoparticles in water, can generate a distributed pressure difference across the phase interface in an immiscible two-phase flow under an external magnetic field. In water-wet porous media, this non-uniform pressure difference may be used to mobilize the non-wetting phase, e.g. oil, trapped in the pores. Previous numerical work by Soares et al. of two-dimensional single-pore model showed enhanced non-wetting phase recovery with water-based ferrofluid under certain magnetic field directions and decreased recovery under other directions. However, the magnetic field selectively concentrates in the high magnetic permeability ferrofluid which fills the small corners between the non-wetting phase and the solid wall. The magnetic field induced pressure is proportional to the square of local magnetic field strength and its normal component, and makes a significant impact on the non-wetting phase deformation. The two-dimensional model omitted the effect of most of these corners and is not sufficient to compute the magnetic-field-induced pressure difference or to predict the non-wetting blob deformation. Further, it is not clear that 3D effects on magnetic field in an irregular geometry can be approximated in 2D. We present a three-dimensional immiscible two-phase flow model to simulate the deformation of a non-wetting liquid blob in a single pore filled with a ferrofluid under a uniform external magnetic field. The ferrofluid is modeled as a uniform single phase because the nanoparticles are 104 times smaller than the pore. The open source CFD solver library OpenFOAM is used for the simulations based on the volume of fluid method. Simulations are performed in a converging-diverging channel model on different magnetic field direction, different initial oil saturations, and different pore shapes. Results indicate that the external magnetic field always stretches the non-wetting blob away from the solid channel wall. A magnetic

  13. Novel Composite Powders with Uniform TiB2 Nano-Particle Distribution for 3D Printing

    Directory of Open Access Journals (Sweden)

    Mengxing Chen

    2017-03-01

    Full Text Available It is reported that the ductility and strength of a metal matrix composite could be concurrently improved if the reinforcing particles were of the size of nanometers and distributed uniformly. In this paper, we revealed that gas atomization solidification could effectively disperse TiB2 nanoparticles in the Al alloy matrix due to its fast cooling rate and the coherent orientation relationship between TiB2 particles and α-Al. Besides, nano-TiB2 led to refined equiaxed grain structures. Furthermore, the composite powders with uniformly embedded nano-TiB2 showed improved laser absorptivity. The novel composite powders are well suited for selective laser melting.

  14. Hard and soft supersymmetry breaking for ‘graphinos’ in uniform magnetic fields

    International Nuclear Information System (INIS)

    Hernández-Ortíz, S; Raya, A; Murguía, G

    2012-01-01

    Using irreducible and reducible representations of the Dirac matrices, we study the two- and four-component quantum mechanical supersymmetric (SUSY) theories for ultrarelativistic fermions in (2 + 1) dimensions (‘graphinos’) in a background uniform magnetic field perpendicular to their plane of motion. We then consider ordinary and parity-violating mass terms and identify the former as a soft SUSY breaking term and the latter as the hard SUSY breaking one. (paper)

  15. Optimization of wall thickness and lay-up for the shell-like composite structure loaded by non-uniform pressure field

    Science.gov (United States)

    Shevtsov, S.; Zhilyaev, I.; Oganesyan, P.; Axenov, V.

    2017-01-01

    The glass/carbon fiber composites are widely used in the design of various aircraft and rotorcraft components such as fairings and cowlings, which have predominantly a shell-like geometry and are made of quasi-isotropic laminates. The main requirements to such the composite parts are the specified mechanical stiffness to withstand the non-uniform air pressure at the different flight conditions and reduce a level of noise caused by the airflow-induced vibrations at the constrained weight of the part. The main objective of present study is the optimization of wall thickness and lay-up of composite shell-like cowling. The present approach assumes conversion of the CAD model of the cowling surface to finite element (FE) representation, then its wind tunnel testing simulation at the different orientation of airflow to find the most stressed mode of flight. Numerical solutions of the Reynolds averaged Navier-Stokes (RANS) equations supplemented by k-w turbulence model provide the spatial distributions of air pressure applied to the shell surface. At the formulation of optimization problem the global strain energy calculated within the optimized shell was assumed as the objective. A wall thickness of the shell had to change over its surface to minimize the objective at the constrained weight. We used a parameterization of the problem that assumes an initiation of auxiliary sphere with varied radius and coordinates of the center, which were the design variables. Curve that formed by the intersection of the shell with sphere defined boundary of area, which should be reinforced by local thickening the shell wall. To eliminate a local stress concentration this increment was defined as the smooth function defined on the shell surface. As a result of structural optimization we obtained the thickness of shell's wall distribution, which then was used to design the draping and lay-up of composite prepreg layers. The global strain energy in the optimized cowling was reduced in2

  16. Impact of compressibility and a guide field on Fermi acceleration during magnetic island coalescence

    Science.gov (United States)

    Montag, Peter; Egedal, Jan; Lichko, Emily; Wetherton, Blake

    2017-10-01

    Previous work has shown that Fermi acceleration can be an effective heating mechanism during magnetic island coalescence, where electrons may undergo repeated reflections as the magnetic field lines contract. This energization has the potential to account for the power-law distributions of particle energy inferred from observations of solar flares. Here, we develop a generalized framework for the analysis of Fermi acceleration that can incorporate the effects of compressibility and non-uniformity along field lines, which have commonly been neglected in previous treatments of the problem. Applying this framework to the simplified case of the uniform flux tube allows us to find both the power-law scaling of the distribution function and the rate at which the power-law behavior develops. We find that a guide magnetic field of order unity effectively suppresses the development of power-law distributions. The work was supported by NASA Grant No. NNX14AC68G, NSF GEM Grant No. 1405166, NSF Award 1404166, and NASA Award NNX15AJ73G.

  17. Roles of ethylene glycol solvent and polymers in preparing uniformly distributed MgO nanoparticles

    Directory of Open Access Journals (Sweden)

    Chunxi Hai

    2017-06-01

    Full Text Available This study focus on specifying the roles of solvent ethylene glycol (EG and polymers for synthesis of uniformly distributed magnesium oxide (MgO nanoparticles with average crystallite size of around 50 nm through a modified polyol method. Based on different characterization results, it was concluded that, Mg2+ ions was precipitated by the −OH and CO32− ions decomposed from urea in ethylene glycol (EG medium (CO(NH22 → NH3 + HNCO, HNCO + H2O → NH3 + CO2, thus forming well crystallized Mg5(CO34(OH2 (H2O4 precursor which could be converted to MgO by calcination. Surface protectors PEG and PVP have no obvious influences on cyrtsal structure, morphology and size uniformity of as-prepared precursors and target MgO nanoparticles. In comparison with polymers PEG and PVP, solvent EG plays an important role in controlling the morphology and diameter uniformity of MgO nanoparticles.

  18. Dynamics of leaching a uniformly fissured ore body

    International Nuclear Information System (INIS)

    Ignatov, A.A.; Proskurin, S.A.

    1987-01-01

    Mathematical simulation was used to study the dynamics of mass transfer during the percolation of a reagent solution through a packing of coarse ore particles. The uniformly fissured ore body was represented by a cubic packing of spherical particles of constant radius, formed from a chemically inert silicate cement with a uniformly distributed soluble mineral component. The rate of percolation of the reagent through the packing was constant. The proposed model can be used to find the conditions for underground hydrodynamic leaching. The rate of non-catalytic solid-liquid reaction was deduced on the basis of both the kinetics of dissolution of the mineral component of the ore and the rate of diffusion of the dissolved substance

  19. A numerical study on the importance of non-uniform index modification during femtosecond grating inscription in microstructured optical fibers

    Science.gov (United States)

    Baghdasaryan, Tigran; Geernaert, Thomas; Thienpont, Hugo; Berghmans, Francis

    2016-04-01

    Fiber Bragg grating (FBG) inscription methods based on femtosecond laser sources are becoming increasingly popular owing to the (usually) non-linear nature of the index modification mechanism and to the resulting advantages. They allow, for example, fabricating fiber gratings that can survive temperatures exceeding 700°C, which can be an asset in the domain of fiber sensing. However applying femtosecond laser based grating fabrication to microstructured optical fibers (MOFs) can be challenging due to the presence of the air holes in the fiber cladding. The microstructured cladding not only impedes light delivery to the core in most cases, but also causes a non-uniform intensity distribution in the MOF core. To deal with these challenges we present a modeling approach that allows simulating how the reflectivity of the grating and the nature of the index modulation are affected by the inscription conditions. We rely on transverse coupling simulations, empirical data and coupled mode analysis to model the induced index change and the resulting grating reflectivity. For IR femtosecond grating inscription we show that due to the intensity redistribution in the core region, irreversible Type II index changes can be induced in a MOF at laser peak intensities below the Type II threshold for step-index fibers. The resulting non-uniform induced index change has repercussions on the reflection spectrum of the grating as well. Our coupled mode analysis reveals, for example, that although the average index change in the core region can be high, the partial overlap of the core mode with the index change region limits the reflectivity of the grating.

  20. Optimizing the field distribution of a Halbach type permanent magnet cylinder using the soft iron and superhard magnet

    Science.gov (United States)

    Xu, Xiaonong; Lu, Dingwei; Xu, Xibin; Yu, Yang; Gu, Min

    2018-01-01

    When a conventional Halbach type Hollow Cylindrical Permanent Magnet Array (HCPMA) is used to generate magnetic induction over the magnitude of coercivity μ0Hc, some detrimental parasitic magnetic phenomena, such as the demagnetization, magnetization reversal, and vortexes of magnetization, can appear in the interior of the magnets. We present a self-consistent quantitative analysis of the magnetization and magnetic induction distributions inside the magnetic array by considering the anisotropic and nonlinear magnetization functions of the materials consisting of the array. These numeric simulations reveal novel magnetization structures resulted from the self-field of array. We demonstrate that both the field uniformity and magnetic flux in the pole gap can be modulated by partially substituting the magnets of high energy products with the soft irons and the superhard magnets. We also show how the optimized substitution parameters can be obtained for a HCPMA achieving the best field uniformity or the maximum magnetic flux.

  1. Physical correction model for automatic correction of intensity non-uniformity in magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Stefan Leger

    2017-10-01

    Conclusion: The proposed PCM algorithm led to a significantly improved image quality compared to the originally acquired images, suggesting that it is applicable to the correction of MRI data. Thus it may help to reduce intensity non-uniformity which is an important step for advanced image analysis.

  2. Effect of scandia doping method on the emission uniformity of scandate cathode with Sc{sub 2}O{sub 3}–W matrix

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jinshu, E-mail: wangjsh@bjut.edu.cn; Lai, Chen; Liu, Wei; Yang, Fan; Zhang, Xizhu; Cui, Yuntao; Zhou, Meiling

    2013-09-01

    Graphical abstract: Emission uniformity of the cathodes prepared by mechanical mixing (a) and spray drying method (b). - Highlights: • The emission uniformity of scandate cathodes has been quantitively obtained. • The nanoparticles on the cathode surface lead to the electric field enhancement. • The cathode prepared by spray drying method exhibits good emission uniformity. - Abstract: Scandia doped tungsten matrix dispenser cathodes were manufactured using scandia doped tungsten powder prepared by mechanical mixing, liquid–solid doping and a spray drying method. It is found the macrostructure of the cathode depended on the powder preparation method. The cathode prepared using the powder prepared by spray drying method had a homogenous and porous matrix characterized with grains with a diameter of less than 1 μm and with many nanoparticles distributing uniformly around these grains. The cathode with submicron structure and uniform distribution of scandia exhibited good emission uniformity. The emission uniformity ΔJ/J of the cathode prepared by spray drying method was 0.17, about 6 times lower than that of the cathode prepared by mechanical mixing method. The calculation results showed that the nanoparticles led to electric field enhancement. A Ba–Sc–O multilayer on the cathode surface and nanoparticles distributing mainly on W grains contributed to the emission property of the cathode.

  3. Assessment of a non-uniform heat flux correction model to predicting CHF in PWR rod bundles

    International Nuclear Information System (INIS)

    Dae-Hyun, Hwang; Sung-Quun, Zee

    2001-01-01

    The full text follows. The prediction of CHF (critical heat flux) has been, in most cases, based on the empirical correlation. For PWR fuel assemblies the local parameter correlation requires the local thermal-hydraulic conditions usually calculated by a subchannel analysis code. The cross-sectional averaged fluid conditions of the subchannel, however, are not sufficient for determining CHF, especially for the cases of non-uniform axial heat flux distributions. Many investigators have studied the effect of the upstream heat flux on the CHF. In terms of the upstream memory effect, two different approaches have been considered as the limiting cases. The 'local conditions' hypothesis assumes that there is a unique relationship between the CHF and the local thermal-hydraulic conditions, and consequently there is no memory effect. In the 'overall power' hypothesis, on the other hand, it is assumed that the total power which can be fed into the tube with nonuniform heating will be the same as that for a uniformly heated tube of the same heated length with the same inlet conditions. Thus the CHF is totally influenced by the upstream heat flux distribution. In view of some experimental investigations such as the DeBortoli's test, it revealed that the two approaches are inadequate in general. It means that the local critical heat flux may be affected to some extent by the heat flux distribution upstream of the CHF location. Some correction-factor models have been suggested to take into account the upstream memory effect. Typically, Tong devised a correction factor on the basis of the heat balance of the superheated liquid layer that is spread underneath a highly viscous bubbly layer along the heated surface. His physical model suggested that the fluid enthalpy obtained from an energy balance of the superheated liquid layer is a representative quantity for the onset of DNB (departure nucleate boiling). A theoretically based correction factor model has been proposed by the

  4. Decomposed Photo Response Non-Uniformity for Digital Forensic Analysis

    Science.gov (United States)

    Li, Yue; Li, Chang-Tsun

    The last few years have seen the applications of Photo Response Non-Uniformity noise (PRNU) - a unique stochastic fingerprint of image sensors, to various types of digital forensic investigations such as source device identification and integrity verification. In this work we proposed a new way of extracting PRNU noise pattern, called Decomposed PRNU (DPRNU), by exploiting the difference between the physical andartificial color components of the photos taken by digital cameras that use a Color Filter Array for interpolating artificial components from physical ones. Experimental results presented in this work have shown the superiority of the proposed DPRNU to the commonly used version. We also proposed a new performance metrics, Corrected Positive Rate (CPR) to evaluate the performance of the common PRNU and the proposed DPRNU.

  5. Hidden singularities in non-abelian gauge fields

    International Nuclear Information System (INIS)

    Bollini, C.G.; Giambiagi, J.J.; Tiomno, J.

    1978-01-01

    It is shown that the potential (and field) of a non-abelian gauge theory is not well determined when it has a singular point. When this is the cause, it is important to specify the regularization procedure used to give a precise definition of physical quantities at the singularity at any stage of the computation. The fact that a certain A sub(μ) (associated with the given regularization) represents the vacuum when F sub(μν) is a zero distribution not only on the global space but also in all its projections to arbitrary subspaces is discussed. The example used as a base for the discussion is A vetor = i (sigma vetor Λ r vetor / r 2 ). For this example it is shown that different regularizations give the same field in the global space but they give different distributions when projected to subspaces containing the singular point [pt

  6. Influence of the magnetic field profile on ITER conductor testing

    International Nuclear Information System (INIS)

    Nijhuis, A; Ilyin, Y; Kate, H H J ten

    2006-01-01

    We performed simulations with the numerical CUDI-CICC code on a typical short ITER (International Thermonuclear Experimental Reactor) conductor test sample of dual leg configuration, as usually tested in the SULTAN test facility, and made a comparison with the new EFDA-Dipole test facility offering a larger applied DC field region. The new EFDA-Dipole test facility, designed for short sample testing of conductors for ITER, has a homogeneous high field region of 1.2 m, while in the SULTAN facility this region is three times shorter. The inevitable non-uniformity of the current distribution in the cable, introduced by the joints at both ends, has a degrading effect on voltage-current (VI) and voltage-temperature (VT) characteristics, particularly for these short samples. This can easily result in an underestimation or overestimation of the actual conductor performance. A longer applied DC high field region along a conductor suppresses the current non-uniformity by increasing the overall longitudinal cable electric field when reaching the current sharing mode. The numerical interpretation study presented here gives a quantitative analysis for a relevant practical case of a test of a short sample poloidal field coil insert (PFCI) conductor in SULTAN. The simulation includes the results of current distribution analysis from self-field measurements with Hall sensor arrays, current sharing measurements and inter-petal resistance measurements. The outcome of the simulations confirms that the current uniformity improves with a longer high field region but the 'measured' VI transition is barely affected, though the local peak voltages become somewhat suppressed. It appears that the location of the high field region and voltage taps has practically no influence on the VI curve as long as the transverse voltage components are adequately cancelled. In particular, for a thin conduit wall, the voltage taps should be connected to the conduit in the form of an (open) azimuthally

  7. A Non-Equilibrium Sediment Transport Model for Dam Break Flow over Moveable Bed Based on Non-Uniform Rectangular Mesh

    Directory of Open Access Journals (Sweden)

    Gangfeng Wu

    2018-05-01

    Full Text Available The use of multiple-level non-uniform rectangular mesh in coupled flow and sediment transport modeling is preferred to achieve high accuracy in important region without increasing computational cost greatly. Here, a robust coupled hydrodynamic and non-equilibrium sediment transport model is developed on non-uniform rectangular mesh to simulate dam break flow over movable beds. The enhanced shallow water and sediment transport equations are adopted to consider the mass and momentum exchange between the flow phase and sediment phase. The flux at the interface is calculated by the positivity preserving central upwind scheme, which belongs to Godunov-type Riemann-problem-solver-free central schemes and is less expensive than other popular Riemann solvers while still capable of tracking wet/dry fronts accurately. The nonnegative water depth reconstruction method is used to achieve second-order accuracy in space. The model was first verified against two laboratory experiments of dam break flow over irregular fixed bed. Then the quantitative performance of the model was further investigated by comparing the computational results with measurement data of dam break flow over movable bed. The good agreements between the measurements and the numerical simulations are found for the flow depth, velocity and bed changes.

  8. Uniform-related infection control practices of dental students

    Directory of Open Access Journals (Sweden)

    Aljohani Y

    2017-04-01

    Full Text Available Yazan Aljohani,1 Mohammed Almutadares,1 Khalid Alfaifi,1 Mona El Madhoun,1 Maysoon H Albahiti,2 Nadia Al-Hazmi3 1Internship Program, Faculty of dentistry, King Abdulaziz University, 2Department of Endodontics, King Abdulaziz University, 3Department of Oral Biology, King Abdulaziz University, Faculty of Dentistry, Jeddah, Saudi Arabia Background: Uniform-related infection control practices are sometimes overlooked and underemphasized. In Saudi Arabia, personal protective equipment must meet global standards for infection control, but the country’s Islamic legislature also needs to be taken into account. Aim: To assess uniform-related infection control practices of a group of dental students in a dental school in Saudi Arabia and compare the results with existing literature related to cross-contamination through uniforms in the dental field. Method: A questionnaire was formulated and distributed to dental students at King Abdulaziz University Faculty of Dentistry in Jeddah, Saudi Arabia, which queried the students about their uniform-related infection control practices and their methods and frequency of laundering and sanitizing their uniforms, footwear, and name tags. Results: There is a significant difference between genders with regard to daily uniform habits. The frequency of uniform washing was below the standard and almost 30% of students were not aware of how their uniforms are washed. Added to this, there is no consensus on a unified uniform for male and female students. Conclusion: Information on preventing cross-contamination through wearing uniforms must be supplied, reinforced, and emphasized while taking into consideration the cultural needs of the Saudi society. Keywords: cross-contamination, infection control, dental students, uniforms

  9. Oscillations of oblate drop between heterogeneous plates under uniform electric field

    Science.gov (United States)

    Kashina, M. A.; Alabuzhev, A. A.

    2018-01-01

    The forced oscillations of the incompressible fluid drop under the action of the uniform electric field are considered. In equilibrium, the drop has the form of a circular cylinder bounded axially by the parallel solid planes; the contact angle is right. An incompressible fluid of different density surrounds the drop. The external electric field acts as an external force that causes motion of the contact line. In order to describe this contact line motion, the modified Hocking boundary condition is applied: the velocity of the contact line is proportional to the deviation of the contact angle and the speed of the fast relaxation processes, whose frequency is proportional to twice the frequency of the electric field. The case of heterogeneous plates is investigated. We assume that the Hocking parameter depends on the polar angle in this case. The function describing the change in the coefficient of the interaction between the plate and the fluid (the contact line) is expanded in a series of the Laplace operator eigenfunctions.

  10. A non-uniform three-gap buncher cavity with suppression of transverse-electromagnetic mode leakage in the triaxial klystron amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Zumin; Zhang, Jun, E-mail: zhangjun-nudt@126.com; Zhong, Huihuang; Zhu, Danni; Qiu, Yongfeng [College of Optoelectric Science and Engineering, National University of Defense Technology, Changsha, Hunan 410073 (China)

    2014-01-15

    The triaxial klystron amplifier is an efficient high power relativistic klystron amplifier operating at high frequencies due to its coaxial structure with large radius. However, the coaxial structures result in coupling problems among the cavities as the TEM mode is not cut-off in the coaxial tube. Therefore, the suppression of the TEM mode leakage, especially the leakage from the buncher cavity to the input cavity, is crucial in the design of a triaxial klystron amplifier. In this paper, a non-uniform three-gap buncher cavity is proposed to suppress the TEM mode leakage. The cold cavity analysis shows that the non-uniform three-gap buncher cavity can significantly suppress the TEM mode generation compared to a uniform three-gap buncher cavity. Particle-in-cell simulation shows that the power leakage to the input cavity is less than 1.5‰ of the negative power in the buncher cavity and the buncher cavity can efficiently modulate an intense relativistic electron beam free of self-oscillations. A fundamental current modulation depth of 117% is achieved by employing the proposed non-uniform buncher cavity into an X-band triaxial amplifier, which results in the high efficiency generation of high power microwave.

  11. Incorporation of Collision Probability Method in STREAM to Consider Non-uniform Material Composition in Fuel Subregions

    International Nuclear Information System (INIS)

    Choi, Sooyoung; Choe, Jiwon; Lee, Deokjung

    2016-01-01

    STREAM uses a pin-based slowing-down method (PSM) which solves pointwise energy slowing-down problems with sub-divided fuel pellet, and shows a great performance in calculating effective cross-section (XS). Various issues in the conventional resonance treatment methods (i.e., approximations on resonance scattering source, resonance interference effect, and intrapellet self-shielding effect) were successfully resolved by PSM. PSM assumes that a fuel rod has a uniform material composition and temperature even though PSM calculates spatially dependent effective XSs of fuel subregions. When the depletion calculation or thermal/hydraulic (T/H) coupling are performed with sub-divided material meshes, each subregion has its own material condition depending on position. It was reported that the treatment of distributed temperature is important to calculate an accurate fuel temperature coefficient (FTC). In order to avoid the approximation in PSM, the collision probability method (CPM) has been incorporated as a calculation option. The resonance treatment method, PSM, used in the transport code STREAM has been enhanced to accurately consider a non-uniform material condition. The method incorporates CPM in computing collision probability of isolated fuel pin. From numerical tests with pin-cell problems, STREAM with the method showed very accurate multiplication factor and FTC results less than 83 pcm and 1.43 % differences from the references, respectively. The original PSM showed larger differences than the proposed method but still has a high accuracy

  12. Incorporation of Collision Probability Method in STREAM to Consider Non-uniform Material Composition in Fuel Subregions

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sooyoung; Choe, Jiwon; Lee, Deokjung [UNIST, Ulsan (Korea, Republic of)

    2016-10-15

    STREAM uses a pin-based slowing-down method (PSM) which solves pointwise energy slowing-down problems with sub-divided fuel pellet, and shows a great performance in calculating effective cross-section (XS). Various issues in the conventional resonance treatment methods (i.e., approximations on resonance scattering source, resonance interference effect, and intrapellet self-shielding effect) were successfully resolved by PSM. PSM assumes that a fuel rod has a uniform material composition and temperature even though PSM calculates spatially dependent effective XSs of fuel subregions. When the depletion calculation or thermal/hydraulic (T/H) coupling are performed with sub-divided material meshes, each subregion has its own material condition depending on position. It was reported that the treatment of distributed temperature is important to calculate an accurate fuel temperature coefficient (FTC). In order to avoid the approximation in PSM, the collision probability method (CPM) has been incorporated as a calculation option. The resonance treatment method, PSM, used in the transport code STREAM has been enhanced to accurately consider a non-uniform material condition. The method incorporates CPM in computing collision probability of isolated fuel pin. From numerical tests with pin-cell problems, STREAM with the method showed very accurate multiplication factor and FTC results less than 83 pcm and 1.43 % differences from the references, respectively. The original PSM showed larger differences than the proposed method but still has a high accuracy.

  13. Heating of charged particles by electrostatic wave propagating perpendicularly to uniform magnetic field

    International Nuclear Information System (INIS)

    Niu, Keishiro; Shimojo, Takashi.

    1978-02-01

    Increase in kinetic energy of a charged particle, affected by an electrostatic wave propagating perpendicularly to a uniform magnetic field, is obtained for both the initial and later stages. Detrapping time of the particle from the potential dent of the electrostatic wave and energy increase during trapping of the particle is analytically derived. Numerical simulations are carried out to support theoretical results. (auth.)

  14. High magnetic field uniformity superconducting magnet for a movable polarized target

    International Nuclear Information System (INIS)

    Anishchenko, N.G.; Bartenev, V.D.; Blinov, N.A.

    1998-01-01

    The superconducting polarizing magnet was constructed for movable polarized target (MPT) with working volume 200 mm long and 30 mm in diameter. The magnet provides a polarizing magnetic field up to 6 T with the uniformity of 4.5 x 10 -4 in the working volume of the target. The magnet windings are made of a NbTi wire, impregnated with the epoxy resin and placed in the horizontal cryostat with 'warm' aperture diameter of 96 mm. The design and technology of the magnet winding are described. Results of the magnetic field map measurements using a NMR-magnetometer are given. The MPT set-up is installed in the beam line of polarized neutrons produced by break-up of polarized deuterons extracted from the Synchrophasotron of the Laboratory of High Energies (LHE), JINR, Dubna

  15. Liquid toroidal drop under uniform electric field

    Science.gov (United States)

    Zabarankin, Michael

    2017-06-01

    The problem of a stationary liquid toroidal drop freely suspended in another fluid and subjected to an electric field uniform at infinity is addressed analytically. Taylor's discriminating function implies that, when the phases have equal viscosities and are assumed to be slightly conducting (leaky dielectrics), a spherical drop is stationary when Q=(2R2+3R+2)/(7R2), where R and Q are ratios of the phases' electric conductivities and dielectric constants, respectively. This condition holds for any electric capillary number, CaE, that defines the ratio of electric stress to surface tension. Pairam and Fernández-Nieves showed experimentally that, in the absence of external forces (CaE=0), a toroidal drop shrinks towards its centre, and, consequently, the drop can be stationary only for some CaE>0. This work finds Q and CaE such that, under the presence of an electric field and with equal viscosities of the phases, a toroidal drop having major radius ρ and volume 4π/3 is qualitatively stationary-the normal velocity of the drop's interface is minute and the interface coincides visually with a streamline. The found Q and CaE depend on R and ρ, and for large ρ, e.g. ρ≥3, they have simple approximations: Q˜(R2+R+1)/(3R2) and CaE∼3 √{3 π ρ / 2 } (6 ln ⁡ρ +2 ln ⁡[96 π ]-9 )/ (12 ln ⁡ρ +4 ln ⁡[96 π ]-17 ) (R+1 ) 2/ (R-1 ) 2.

  16. Some properties of a non-static uniform density sphere with center singularity

    International Nuclear Information System (INIS)

    Knutsen, H.

    1984-01-01

    A class of exact models for non-static uniform density spheres with pressure gradient and singularity is investigated. Necessary and sufficient conditions are given for the pressure gradient to be negative and for the circumference of the sphere to be an increasing function of radial coordinate. The time history of marginally trapped surfaces are studied, and it is found that for physically acceptable models the singularity is always hidden by a trapped surface. (Auth.)

  17. Coherent states of non-relativistic electron in the magnetic-solenoid field

    International Nuclear Information System (INIS)

    Bagrov, V G; Gavrilov, S P; Filho, D P Meira; Gitman, D M

    2010-01-01

    In the present work we construct coherent states in the magnetic-solenoid field, which is a superposition of the Aharonov-Bohm field and a collinear uniform magnetic field. In the problem under consideration there are two kinds of coherent states, those which correspond to classical trajectories which embrace the solenoid and those which do not. The constructed coherent states reproduce exactly classical trajectories, maintain their form under the time evolution and form a complete set of functions, which can be useful in semiclassical calculations. In the absence of the solenoid field these states are reduced to the well known in the case of uniform magnetic field Malkin-Man'ko coherent states.

  18. Study of the distribution of maxima and minima in multiple sequential images of uniformity; Estudio de la distribucion de maximos y minimos en multiples imagenes secuenciales de uniformidad

    Energy Technology Data Exchange (ETDEWEB)

    Llacer Martos, S.; Puchal Ane, R.

    2011-07-01

    To characterize the uniformity of a gamma camera extrinsic used integral uniformity coefficient is calculated with the value of two pixels, the maximum and minimum, single source acquisition of a flat and uniform. This method does not take into account the fact that if a gamma camera having a uniform response, the distribution of these items should be random. In this paper we study how these points are distributed in a succession of large numbers of uniform images.

  19. Non-uniform muscle fat replacement along the proximodistal axis in Duchenne muscular dystrophy.

    Science.gov (United States)

    Hooijmans, M T; Niks, E H; Burakiewicz, J; Anastasopoulos, C; van den Berg, S I; van Zwet, E; Webb, A G; Verschuuren, J J G M; Kan, H E

    2017-05-01

    The progressive replacement of muscle tissue by fat in Duchenne muscular dystrophy (DMD) has been studied using quantitative MRI between, but not within, individual muscles. We studied fat replacement along the proximodistal muscle axis using the Dixon technique on a 3T MR scanner in 22 DMD patients and 12 healthy controls. Mean fat fractions per muscle per slice for seven lower and upper leg muscles were compared between and within groups assuming a parabolic distribution. Average fat fraction for a small central slice stack and a large coverage slice stack were compared to the value when the stack was shifted one slice (15 mm) up or down. Higher fat fractions were observed in distal and proximal muscle segments compared to the muscle belly in all muscles of the DMD subjects (p muscle end regions are exposed to higher mechanical strain, which points towards mechanical disruption of the sarcolemma as one of the key factors in the pathophysiology. Overall, this non-uniformity in fat replacement needs to be taken into account to prevent sample bias when applying quantitative MRI as biomarker in clinical trials for DMD. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Silver doped hydroxyapatite coatings by sacrificial anode deposition under magnetic field.

    Science.gov (United States)

    Swain, S; Rautray, T R

    2017-09-13

    Uniform distribution of silver (Ag) in the hydroxyapatite (HA) coated Ti surface has been a concern for which an attempt has been made to dope Ag in HA coating with and without magnetic field. Cathodic deposition technique was employed to coat Ag incorporated hydroxyapatite coating using a sacrificial silver anode method by using NdFeB bar magnets producing 12 Tesla magnetic field. While uniform deposition of Ag was observed in the coatings under magnetic field, dense coating was evident in the coating without magnetic field conditions. Uniformly distributed Ag incorporated HA in the present study has potential to fight microorganism while providing osseoconduction properties of the composite coating.

  1. Complementary variational principle method applied to thermal conductivities of a plasma in a uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, A K; Gupta, S C [Punjabi Univ., Patiala (India). Dept. of Physics

    1982-12-14

    The complementary variational principles method (CVP) is applied to the thermal conductivities of a plasma in a uniform magnetic field. The results of computations show that the CVP derived results are very useful.

  2. Polarization of spin-1 particles without an anomalous magnetic moment in a uniform magnetic field

    OpenAIRE

    Silenko, Alexander J.

    2008-01-01

    The polarization operator projections onto four directions remain unchanged for spin-1 particles without an anomalous magnetic moment in a uniform magnetic field. The approximate conservation of the polarization operator projections onto the horizontal axes of the cylindrical coordinate system takes place.

  3. Non-Gaussian probability distributions of solar wind fluctuations

    Directory of Open Access Journals (Sweden)

    E. Marsch

    Full Text Available The probability distributions of field differences ∆x(τ=x(t+τ-x(t, where the variable x(t may denote any solar wind scalar field or vector field component at time t, have been calculated from time series of Helios data obtained in 1976 at heliocentric distances near 0.3 AU. It is found that for comparatively long time lag τ, ranging from a few hours to 1 day, the differences are normally distributed according to a Gaussian. For shorter time lags, of less than ten minutes, significant changes in shape are observed. The distributions are often spikier and narrower than the equivalent Gaussian distribution with the same standard deviation, and they are enhanced for large, reduced for intermediate and enhanced for very small values of ∆x. This result is in accordance with fluid observations and numerical simulations. Hence statistical properties are dominated at small scale τ by large fluctuation amplitudes that are sparsely distributed, which is direct evidence for spatial intermittency of the fluctuations. This is in agreement with results from earlier analyses of the structure functions of ∆x. The non-Gaussian features are differently developed for the various types of fluctuations. The relevance of these observations to the interpretation and understanding of the nature of solar wind magnetohydrodynamic (MHD turbulence is pointed out, and contact is made with existing theoretical concepts of intermittency in fluid turbulence.

  4. Applying controlled non-uniform deformation for in vitro studies of cell mechanobiology.

    Science.gov (United States)

    Balestrini, Jenna L; Skorinko, Jeremy K; Hera, Adriana; Gaudette, Glenn R; Billiar, Kristen L

    2010-06-01

    Cells within connective tissues routinely experience a wide range of non-uniform mechanical loads that regulate many cell behaviors. In this study, we developed an experimental system to produce complex strain patterns for the study of strain magnitude, anisotropy, and gradient effects on cells in culture. A standard equibiaxial cell stretching system was modified by affixing glass coverslips (5, 10, or 15 mm diameter) to the center of 35 mm diameter flexible-bottomed culture wells. Ring inserts were utilized to limit applied strain to different levels in each individual well at a given vacuum pressure thus enabling parallel experiments at different strain levels. Deformation fields were measured using high-density mapping for up to 6% applied strain. The addition of the rigid inclusion creates strong circumferential and radial strain gradients, with a continuous range of stretch anisotropy ranging from strip biaxial to equibiaxial strain and radial strains up to 24% near the inclusion. Dermal fibroblasts seeded within our 2D system (5 mm inclusions; 2% applied strain for 2 days at 0.2 Hz) demonstrated the characteristic orientation perpendicular to the direction of principal strain. Dermal fibroblasts seeded within fibrin gels (5 mm inclusions; 6% applied strain for 8 days at 0.2 Hz) oriented themselves similarly and compacted their surrounding matrix to an increasing extent with local strain magnitude. This study verifies how inhomogeneous strain fields can be produced in a tunable and simply constructed system and demonstrates the potential utility for studying gradients with a continuous spectrum of strain magnitudes and anisotropies.

  5. Non-Uniform Sampling and J-UNIO Automation for Efficient Protein NMR Structure Determination.

    Science.gov (United States)

    Didenko, Tatiana; Proudfoot, Andrew; Dutta, Samit Kumar; Serrano, Pedro; Wüthrich, Kurt

    2015-08-24

    High-resolution structure determination of small proteins in solution is one of the big assets of NMR spectroscopy in structural biology. Improvements in the efficiency of NMR structure determination by advances in NMR experiments and automation of data handling therefore attracts continued interest. Here, non-uniform sampling (NUS) of 3D heteronuclear-resolved [(1)H,(1)H]-NOESY data yielded two- to three-fold savings of instrument time for structure determinations of soluble proteins. With the 152-residue protein NP_372339.1 from Staphylococcus aureus and the 71-residue protein NP_346341.1 from Streptococcus pneumonia we show that high-quality structures can be obtained with NUS NMR data, which are equally well amenable to robust automated analysis as the corresponding uniformly sampled data. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Magnetic field effect on nanoparticles migration and heat transfer of water/alumina nanofluid in a channel

    Energy Technology Data Exchange (ETDEWEB)

    Malvandi, A., E-mail: amirmalvandi@aut.ac.ir [Department of Mechanical Engineering, Amirkabir University of Technology (Tehran Polytechnic), 424 Hafez Avenue, Tehran (Iran, Islamic Republic of); Ganji, D.D., E-mail: ddg_davood@yahoo.com [Mechanical Engineering Department, Babol Noshirvani University of Technology, Babol (Iran, Islamic Republic of)

    2014-08-01

    The present study is a theoretical investigation of the laminar flow and convective heat transfer of water/alumina nanofluid inside a parallel-plate channel in the presence of a uniform magnetic field. A modified two-component, four-equation, nonhomogeneous equilibrium model was employed for the alumina/water nanofluid, which fully accounted for the effect of the nanoparticle volume fraction distribution. The no-slip condition of the fluid–solid interface is abandoned in favor of a slip condition which appropriately represents the non-equilibrium region near the interface at micro/nano channels. The results obtained indicated that nanoparticles move from the heated walls (nanoparticles depletion) toward the core region of the channel (nanoparticles accumulation) and construct a non-uniform nanoparticles distribution. Moreover, in the presence of the magnetic field, the near wall velocity gradients increase, enhancing the slip velocity and thus the heat transfer rate and pressure drop increase. - Highlights: • Force convection of alumina/water nanofluid inside a parallel-plate channel. • Magnetic field effects on nanoparticles' migration. • Effects of Brownian motion and thermophoresis diffusivities on nanoparticle migration. • Different mechanisms of heat transfer rate based on nanoparticles' diameter.

  7. A Smart Cage With Uniform Wireless Power Distribution in 3D for Enabling Long-Term Experiments With Freely Moving Animals.

    Science.gov (United States)

    Mirbozorgi, S Abdollah; Bahrami, Hadi; Sawan, Mohamad; Gosselin, Benoit

    2016-04-01

    This paper presents a novel experimental chamber with uniform wireless power distribution in 3D for enabling long-term biomedical experiments with small freely moving animal subjects. The implemented power transmission chamber prototype is based on arrays of parallel resonators and multicoil inductive links, to form a novel and highly efficient wireless power transmission system. The power transmitter unit includes several identical resonators enclosed in a scalable array of overlapping square coils which are connected in parallel to provide uniform power distribution along x and y. Moreover, the proposed chamber uses two arrays of primary resonators, facing each other, and connected in parallel to achieve uniform power distribution along the z axis. Each surface includes 9 overlapped coils connected in parallel and implemented into two layers of FR4 printed circuit board. The chamber features a natural power localization mechanism, which simplifies its implementation and ease its operation by avoiding the need for active detection and control mechanisms. A single power surface based on the proposed approach can provide a power transfer efficiency (PTE) of 69% and a power delivered to the load (PDL) of 120 mW, for a separation distance of 4 cm, whereas the complete chamber prototype provides a uniform PTE of 59% and a PDL of 100 mW in 3D, everywhere inside the chamber with a size of 27×27×16 cm(3).

  8. Change in concentration distribution and equivalent rate constant with flow velocity in a boundary layer around a catalyst of non-uniform surface activity; Kotai shokubai taihyomen no kassei no fukin`itsusei ni motozuku kankyo sonai nodo bunpu oyobi toka hanno sokudo teisu no ryusoku ni yoru henka

    Energy Technology Data Exchange (ETDEWEB)

    Konno, J [National Institute for Resources and Environment, Tsukuba (Japan)

    1997-09-25

    In a flow system for vapor/solid catalytic reactions, there is a concentration distribution along the external catalyst surface, observed in the vicinity of the surface. Change in the reaction rate constant is followed for the case where the concentration distribution varies by flow. A 2-dimensional numerical model in which flow field and property conditions are simplified is used to analyze the change on the assumption that high-activity and low-activity sites are regularly distributed over the external catalyst surface. The transport equations for the reactants are numerically solved for given flow fields. It is found that the concentration distribution shape and equivalent reaction rate constant are almost the same as those in a stationary system at Pecret number of around 10 or lower, the concentration distribution gradually becomes uniform whereas equivalent rate constant increases as flow rate increases at Pecret number in a range from around 10 to 10{sup 6}, and they are almost constant at Pecret number beyond around 10{sup 6}. 3 refs., 11 figs., 1 tab.

  9. Application of a non-integer Bessel uniform approximation to inelastic molecular collisions

    International Nuclear Information System (INIS)

    Connor, J.N.L.; Mayne, H.R.

    1979-01-01

    A non-integer Bessel uniform approximation has been used to calculate transition probabilities for collinear atom-oscillator collisions. The collision systems used are a harmonic oscillator interacting via a Lennard-Jones potential and a Morse oscillator interacting via an exponential potential. Both classically allowed and classically forbidden transitions have been treated. The order of the Bessel function is chosen by a physical argument that makes use of information contained in the final-action initial-angle plot. Limitations of this procedure are discussed. It is shown that the non-integer Bessel approximation is accurate for elastic 0 → 0 collisions at high collision energies, where the integer Bessel approximation is inaccurate or inapplicable. (author)

  10. Effect of variable viscosity on laminar convection flow of an electrically conducting fluid in uniform magnetic field

    Directory of Open Access Journals (Sweden)

    Chakraborty S.

    2002-01-01

    Full Text Available The flow of a viscous incompressible electrically conducting fluid on a continuous moving flat plate in presence of uniform transverse magnetic field, is studied. The flat plate which is continuously moving in its own plane with a constant speed is considered to be isothermally heated. Assuming the fluid viscosity as an inverse linear function of temperature, the nature of fluid velocity and temperature in presence of uniform magnetic field are shown for changing viscosity parameter at different layers of the medium. Numerical solutions are obtained by using Runge-Kutta and Shooting method. The coefficient of skin friction and the rate of heat transfer are calculated at different viscosity parameter and Prandt l number. .

  11. Shutterless non-uniformity correction for the long-term stability of an uncooled long-wave infrared camera

    Science.gov (United States)

    Liu, Chengwei; Sui, Xiubao; Gu, Guohua; Chen, Qian

    2018-02-01

    For the uncooled long-wave infrared (LWIR) camera, the infrared (IR) irradiation the focal plane array (FPA) receives is a crucial factor that affects the image quality. Ambient temperature fluctuation as well as system power consumption can result in changes of FPA temperature and radiation characteristics inside the IR camera; these will further degrade the imaging performance. In this paper, we present a novel shutterless non-uniformity correction method to compensate for non-uniformity derived from the variation of ambient temperature. Our method combines a calibration-based method and the properties of a scene-based method to obtain correction parameters at different ambient temperature conditions, so that the IR camera performance can be less influenced by ambient temperature fluctuation or system power consumption. The calibration process is carried out in a temperature chamber with slowly changing ambient temperature and a black body as uniform radiation source. Enough uniform images are captured and the gain coefficients are calculated during this period. Then in practical application, the offset parameters are calculated via the least squares method based on the gain coefficients, the captured uniform images and the actual scene. Thus we can get a corrected output through the gain coefficients and offset parameters. The performance of our proposed method is evaluated on realistic IR images and compared with two existing methods. The images we used in experiments are obtained by a 384× 288 pixels uncooled LWIR camera. Results show that our proposed method can adaptively update correction parameters as the actual target scene changes and is more stable to temperature fluctuation than the other two methods.

  12. Quantum dynamical phenomena of independent electrons in semiconductor superlattices subject to a uniform electric field

    International Nuclear Information System (INIS)

    Bouchard, A.M.

    1994-01-01

    This report discusses the following topics: Bloch oscillations and other dynamical phenomena of electrons in semiconductor superlattices; solvable dynamical model of an electron in a one-dimensional aperiodic lattice subject to a uniform electric field; and quantum dynamical phenomena of electrons in aperiodic semiconductor superlattices

  13. Coherent states of non-relativistic electron in the magnetic-solenoid field

    Energy Technology Data Exchange (ETDEWEB)

    Bagrov, V G [Department of Physics, Tomsk State University, 634050, Tomsk (Russian Federation); Gavrilov, S P; Filho, D P Meira [Institute of Physics, University of Sao Paulo (Brazil); Gitman, D M, E-mail: bagrov@phys.tsu.r, E-mail: gavrilovsergeyp@yahoo.co, E-mail: gitman@dfn.if.usp.b, E-mail: dmeira@dfn.if.usp.b [Institute of Physics, University of Sao Paulo, CP 66318, CEP 05315-970 Sao Paulo (Brazil)

    2010-09-03

    In the present work we construct coherent states in the magnetic-solenoid field, which is a superposition of the Aharonov-Bohm field and a collinear uniform magnetic field. In the problem under consideration there are two kinds of coherent states, those which correspond to classical trajectories which embrace the solenoid and those which do not. The constructed coherent states reproduce exactly classical trajectories, maintain their form under the time evolution and form a complete set of functions, which can be useful in semiclassical calculations. In the absence of the solenoid field these states are reduced to the well known in the case of uniform magnetic field Malkin-Man'ko coherent states.

  14. The uniformity study of non-oxide thin film at device level using electron energy loss spectroscopy

    Science.gov (United States)

    Li, Zhi-Peng; Zheng, Yuankai; Li, Shaoping; Wang, Haifeng

    2018-05-01

    Electron energy loss spectroscopy (EELS) has been widely used as a chemical analysis technique to characterize materials chemical properties, such as element valence states, atoms/ions bonding environment. This study provides a new method to characterize physical properties (i.e., film uniformity, grain orientations) of non-oxide thin films in the magnetic device by using EELS microanalysis on scanning transmission electron microscope. This method is based on analyzing white line ratio of spectra and related extended energy loss fine structures so as to correlate it with thin film uniformity. This new approach can provide an effective and sensitive method to monitor/characterize thin film quality (i.e., uniformity) at atomic level for thin film development, which is especially useful for examining ultra-thin films (i.e., several nanometers) or embedded films in devices for industry applications. More importantly, this technique enables development of quantitative characterization of thin film uniformity and it would be a remarkably useful technique for examining various types of devices for industrial applications.

  15. Acceleration of the charged particles due to chaotic scattering in the combined black hole gravitational field and asymptotically uniform magnetic field

    International Nuclear Information System (INIS)

    Stuchlik, Zdenek; Kolos, Martin

    2016-01-01

    To test the role of large-scale magnetic fields in accretion processes, we study the dynamics of the charged test particles in the vicinity of a black hole immersed into an asymptotically uniform magnetic field. Using the Hamiltonian formalism of the charged particle dynamics, we examine chaotic scattering in the effective potential related to the black hole gravitational field combined with the uniform magnetic field. Energy interchange between the translational and oscillatory modes of the charged particle dynamics provides a mechanism for charged particle acceleration along the magnetic field lines. This energy transmutation is an attribute of the chaotic charged particle dynamics in the combined gravitational and magnetic fields only, the black hole rotation is not necessary for such charged particle acceleration. The chaotic scatter can cause a transition to the motion along the magnetic field lines with small radius of the Larmor motion or vanishing Larmor radius, when the speed of the particle translational motion is largest and it can be ultra-relativistic. We discuss the consequences of the model of ionization of test particles forming a neutral accretion disc, or heavy ions following off-equatorial circular orbits, and we explore the fate of heavy charged test particles after ionization where no kick of heavy ions is assumed and only the switch-on effect of the magnetic field is relevant. We demonstrate that acceleration and escape of the ionized particles can be efficient along the Kerr black hole symmetry axis parallel to the magnetic field lines. We show that a strong acceleration of the ionized particles to ultra-relativistic velocities is preferred in the direction close to the magnetic field lines. Therefore, the process of ionization of Keplerian discs around the Kerr black holes can serve as a model of relativistic jets. (orig.)

  16. Acceleration of the charged particles due to chaotic scattering in the combined black hole gravitational field and asymptotically uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Stuchlik, Zdenek; Kolos, Martin [Silesian University in Opava, Faculty of Philosophy and Science, Institute of Physics and Research Centre of Theoretical Physics and Astrophysics, Opava (Czech Republic)

    2016-01-15

    To test the role of large-scale magnetic fields in accretion processes, we study the dynamics of the charged test particles in the vicinity of a black hole immersed into an asymptotically uniform magnetic field. Using the Hamiltonian formalism of the charged particle dynamics, we examine chaotic scattering in the effective potential related to the black hole gravitational field combined with the uniform magnetic field. Energy interchange between the translational and oscillatory modes of the charged particle dynamics provides a mechanism for charged particle acceleration along the magnetic field lines. This energy transmutation is an attribute of the chaotic charged particle dynamics in the combined gravitational and magnetic fields only, the black hole rotation is not necessary for such charged particle acceleration. The chaotic scatter can cause a transition to the motion along the magnetic field lines with small radius of the Larmor motion or vanishing Larmor radius, when the speed of the particle translational motion is largest and it can be ultra-relativistic. We discuss the consequences of the model of ionization of test particles forming a neutral accretion disc, or heavy ions following off-equatorial circular orbits, and we explore the fate of heavy charged test particles after ionization where no kick of heavy ions is assumed and only the switch-on effect of the magnetic field is relevant. We demonstrate that acceleration and escape of the ionized particles can be efficient along the Kerr black hole symmetry axis parallel to the magnetic field lines. We show that a strong acceleration of the ionized particles to ultra-relativistic velocities is preferred in the direction close to the magnetic field lines. Therefore, the process of ionization of Keplerian discs around the Kerr black holes can serve as a model of relativistic jets. (orig.)

  17. Comparison between measured and computed magnetic flux density distribution of simulated transformer core joints assembled from grain-oriented and non-oriented electrical steel

    Directory of Open Access Journals (Sweden)

    Hamid Shahrouzi

    2018-04-01

    Full Text Available The flux distribution in an overlapped linear joint constructed in the central region of an Epstein Square was studied experimentally and results compared with those obtained using a computational magnetic field solver. High permeability grain-oriented (GO and low permeability non-oriented (NO electrical steels were compared at a nominal core flux density of 1.60 T at 50 Hz. It was found that the experimental results only agreed well at flux densities at which the reluctance of different paths of the flux are similar. Also it was revealed that the flux becomes more uniform when the working point of the electrical steel is close to the knee point of the B-H curve of the steel.

  18. Non-Gaussianity from self-ordering scalar fields

    International Nuclear Information System (INIS)

    Figueroa, Daniel G.; Caldwell, Robert R.; Kamionkowski, Marc

    2010-01-01

    The Universe may harbor relics of the post-inflationary epoch in the form of a network of self-ordered scalar fields. Such fossils, while consistent with current cosmological data at trace levels, may leave too weak an imprint on the cosmic microwave background and the large-scale distribution of matter to allow for direct detection. The non-Gaussian statistics of the density perturbations induced by these fields, however, permit a direct means to probe for these relics. Here we calculate the bispectrum that arises in models of self-ordered scalar fields. We find a compact analytic expression for the bispectrum, evaluate it numerically, and provide a simple approximation that may be useful for data analysis. The bispectrum is largest for triangles that are aligned (have edges k 1 ≅2k 2 ≅2k 3 ) as opposed to the local-model bispectrum, which peaks for squeezed triangles (k 1 ≅k 2 >>k 3 ), and the equilateral bispectrum, which peaks at k 1 ≅k 2 ≅k 3 . We estimate that this non-Gaussianity should be detectable by the Planck satellite if the contribution from self-ordering scalar fields to primordial perturbations is near the current upper limit.

  19. Cell-centered particle weighting algorithm for PIC simulations in a non-uniform 2D axisymmetric mesh

    Science.gov (United States)

    Araki, Samuel J.; Wirz, Richard E.

    2014-09-01

    Standard area weighting methods for particle-in-cell simulations result in systematic errors on particle densities for a non-uniform mesh in cylindrical coordinates. These errors can be significantly reduced by using weighted cell volumes for density calculations. A detailed description on the corrected volume calculations and cell-centered weighting algorithm in a non-uniform mesh is provided. The simple formulas for the corrected volume can be used for any type of quadrilateral and/or triangular mesh in cylindrical coordinates. Density errors arising from the cell-centered weighting algorithm are computed for radial density profiles of uniform, linearly decreasing, and Bessel function in an adaptive Cartesian mesh and an unstructured mesh. For all the density profiles, it is shown that the weighting algorithm provides a significant improvement for density calculations. However, relatively large density errors may persist at outermost cells for monotonically decreasing density profiles. A further analysis has been performed to investigate the effect of the density errors in potential calculations, and it is shown that the error at the outermost cell does not propagate into the potential solution for the density profiles investigated.

  20. Investigation of non-uniformity and inclusions in 6LiInSe2 utilizing laser induced breakdown spectroscopy (LIBS)

    Science.gov (United States)

    Wiggins, Brenden; Tupitsyn, Eugene; Bhattacharya, Pijush; Rowe, Emmanuel; Lukosi, Eric; Chvala, Ondrej; Burger, Arnold; Stowe, Ashley

    2013-09-01

    Impurity analysis and compositional distribution studies have been conducted on a crystal of LiInSe2, a compound semiconductor which recently has been shown to respond to ionizing radiation. IR microscopy and laser induced breakdown spectroscopy (LIBS) revealed the presence of inclusions within the crystal lattice. These precipitates were revealed to be alkali and alkaline earth elemental impurities with non-uniform spatial distribution in the crystal. LIBS compositional maps correlate the presence of these impurities with visual color differences in the crystal as well as a significant shift of the band gap. Further, LIBS revealed variation in the ratio of I-III-VI2 elemental constituents throughout the crystal. Analysis of compositional variation and impurities will aid in discerning optimal synthesis and crystal growth parameters to maximize the mobility-lifetime product and charge collection efficiency in the LiInSe2 crystal. Preliminary charge trapping calculations have also been conducted with the Monte Carlo N-particle eXtended (MCNPx) package indicating preferential trapping of holes during irradiation with thermal neutrons.

  1. Helicons in uniform fields. I. Wave diagnostics with hodograms

    Science.gov (United States)

    Urrutia, J. M.; Stenzel, R. L.

    2018-03-01

    The wave equation for whistler waves is well known and has been solved in Cartesian and cylindrical coordinates, yielding plane waves and cylindrical waves. In space plasmas, waves are usually assumed to be plane waves; in small laboratory plasmas, they are often assumed to be cylindrical "helicon" eigenmodes. Experimental observations fall in between both models. Real waves are usually bounded and may rotate like helicons. Such helicons are studied experimentally in a large laboratory plasma which is essentially a uniform, unbounded plasma. The waves are excited by loop antennas whose properties determine the field rotation and transverse dimensions. Both m = 0 and m = 1 helicon modes are produced and analyzed by measuring the wave magnetic field in three dimensional space and time. From Ampère's law and Ohm's law, the current density and electric field vectors are obtained. Hodograms for these vectors are produced. The sign ambiguity of the hodogram normal with respect to the direction of wave propagation is demonstrated. In general, electric and magnetic hodograms differ but both together yield the wave vector direction unambiguously. Vector fields of the hodogram normal yield the phase flow including phase rotation for helicons. Some helicons can have locally a linear polarization which is identified by the hodogram ellipticity. Alternatively the amplitude oscillation in time yields a measure for the wave polarization. It is shown that wave interference produces linear polarization. These observations emphasize that single point hodogram measurements are inadequate to determine the wave topology unless assuming plane waves. Observations of linear polarization indicate wave packets but not plane waves. A simple qualitative diagnostics for the wave polarization is the measurement of the magnetic field magnitude in time. Circular polarization has a constant amplitude; linear polarization results in amplitude modulations.

  2. Synchronization in a non-uniform network of excitatory spiking neurons

    Science.gov (United States)

    Echeveste, Rodrigo; Gros, Claudius

    Spontaneous synchronization of pulse coupled elements is ubiquitous in nature and seems to be of vital importance for life. Networks of pacemaker cells in the heart, extended populations of southeast asian fireflies, and neuronal oscillations in cortical networks, are examples of this. In the present work, a rich repertoire of dynamical states with different degrees of synchronization are found in a network of excitatory-only spiking neurons connected in a non-uniform fashion. In particular, uncorrelated and partially correlated states are found without the need for inhibitory neurons or external currents. The phase transitions between these states, as well the robustness, stability, and response of the network to external stimulus are studied.

  3. A generic Approach for Reliability Predictions considering non-uniformly Deterioration Behaviour

    International Nuclear Information System (INIS)

    Krause, Jakob; Kabitzsch, Klaus

    2012-01-01

    Predictive maintenance offers the possibility to prognosticate the remaining time until a maintenance action of a machine has to be scheduled. Unfortunately, current predictive maintenance solutions are only suitable for very specific use cases like reliability predictions based on vibration monitoring. Furthermore, they do not consider the fact that machines may deteriorate non-uniformly, depending on external influences (e.g., the work piece material in a milling machine or the changing fruit acid concentration in a bottling plant). In this paper two concepts for a generic predictive maintenance solution which also considers non-uniformly aging behaviour are introduced. The first concept is based on system models representing the health state of a technical system. As these models are usually statically (viz. without a timely dimension) their coefficients are determined periodically and the resulting time series is used as aging indicator. The second concept focuses on external influences (contexts) which change the behaviour of the previous mentioned aging indicators in order to increase the accuracy of reliability predictions. Therefore, context-depended time series models are determined and used to predict machine reliability. Both concepts were evaluated on data of an air ventilation system. Thereby, it could be shown that they are suitable to determine aging indicators in a generic way and to incorporate external influences in the reliability prediction. Through this, the quality of reliability predictions can be significantly increased. In reality this leads to a more accurate scheduling of maintenance actions. Furthermore, the generic character of the solutions makes the concepts suitable for a wide range of aging processes.

  4. Non-equilibrium work distribution for interacting colloidal particles under friction

    International Nuclear Information System (INIS)

    Gomez-Solano, Juan Ruben; July, Christoph; Mehl, Jakob; Bechinger, Clemens

    2015-01-01

    We experimentally investigate the non-equilibrium steady-state distribution of the work done by an external force on a mesoscopic system with many coupled degrees of freedom: a colloidal crystal mechanically driven across a commensurate periodic light field. Since this system mimics the spatiotemporal dynamics of a crystalline surface moving on a corrugated substrate, our results show general properties of the work distribution for atomically flat surfaces undergoing friction. We address the role of several parameters which can influence the shape of the work distribution, e.g. the number of particles used to locally probe the properties of the system and the time interval to measure the work. We find that, when tuning the control parameters to induce particle depinning from the substrate, there is an abrupt change of the shape of the work distribution. While in the completely static and sliding friction regimes the work distribution is Gaussian, non-Gaussian tails show up due to the spatiotemporal heterogeneity of the particle dynamics during the transition between these two regimes. (paper)

  5. Disintegration of fast magnetoacoustic oscillation spectra in non-uniform current-loaded plasma cylinder

    International Nuclear Information System (INIS)

    Girka, I.A.; Stepanov, K.N.

    1990-01-01

    Dispersion equation for fast plasma cylinder with longitudinal current including a weak azimuthal magnetic field β 0v is obtained and analyzed on the basis of perturbation theory. Simple asymptotic expressions for S w , S n and σ k are derived under different limiting cases (propagation of small-scale waves with high values of radial wave number, wave in the uniform cylinder, surface mode etc.). 10 refs.; 1 fig

  6. Three dimensional peristaltic flow of hyperbolic tangent fluid in non-uniform channel having flexible walls

    Directory of Open Access Journals (Sweden)

    M. Ali Abbas

    2016-03-01

    Full Text Available In this present analysis, three dimensional peristaltic flow of hyperbolic tangent fluid in a non-uniform channel has been investigated. We have considered that the pressure is uniform over the whole cross section and the interial effects have been neglected. For this purpose we consider laminar flow under the assumptions of long wavelength (λ→∞ and creeping flow (Re→0 approximations. The attained highly nonlinear equations are solved with the help of Homotopy perturbation method. The influence of various physical parameters of interest is demonstrated graphically for wall tension, mass characterization, damping nature of the wall, wall rigidity, wall elastance, aspect ratio and the Weissenberg number. In this present investigation we found that the magnitude of the velocity is maximum in the center of the channel whereas it is minimum near the walls. Stream lines are also drawn to discuss the trapping mechanism for all the physical parameters. Comparison has also been presented between Newtonian and non-Newtonian fluid.

  7. Penumbra modifier for optimal electron fields combination

    International Nuclear Information System (INIS)

    ElSherbini, N.; Hejazy, M.A.; Khalil, W.

    2003-01-01

    Abutment of two or more electron fields to irradiate extended areas may lead to significant dose inhomogeneities in the junction region. This study describes the geometric and dosimetric characteristics of a device developed to modify the penumbra of an electron beam and therapy improve of dose uniformity in the over lap region when fields are abutted. The device is lipowitz metal block placed on top of the insertion plate of the electron applicator and positioned to stop part of he electron beam on side of field abutment. The air-scattered electrons beyond the block increase the penumbra width from about 1,4 to 2-7-43.4 cm at SSD 100 cm, the modified penumbra is broad and almost linear at all depths for the 6.8, and 15 MeV electron beams used. Film dosimetry was used to obtain profiles, iso-dose distributions, single modified beams and matched fields of 6, 10, and 15 MeV. Wellhofer dosimetry system was used to obtain beam profiles and iso-dose distributions of single modified beams needed for CADPLAN treatment planning system, which used to optimize and compare the skin gap to be used and to quantify the dose uniformity in a junction of the field separation for both modified and non-modified beams. Results are presented for various field configurations without the penumbra modifier; lateral setup error of 2-3 mm may introduce dose variations of 20% or more in the junction region. Similar setup error cause less than 5% dose variations when the penumbra modifier is used to match the field

  8. Unified analytical threshold voltage model for non-uniformly doped dual metal gate fully depleted silicon-on-insulator MOSFETs

    Science.gov (United States)

    Rao, Rathnamala; Katti, Guruprasad; Havaldar, Dnyanesh S.; DasGupta, Nandita; DasGupta, Amitava

    2009-03-01

    The paper describes the unified analytical threshold voltage model for non-uniformly doped, dual metal gate (DMG) fully depleted silicon-on-insulator (FDSOI) MOSFETs based on the solution of 2D Poisson's equation. 2D Poisson's equation is solved analytically for appropriate boundary conditions using separation of variables technique. The solution is then extended to obtain the threshold voltage of the FDSOI MOSFET. The model is able to handle any kind of non-uniform doping, viz. vertical, lateral as well as laterally asymetric channel (LAC) profile in the SOI film in addition to the DMG structure. The analytical results are validated with the numerical simulations using the device simulator MEDICI.

  9. Non-uniformly polarized beams across their transverse profiles: an introductory study for undergraduate optics courses

    International Nuclear Information System (INIS)

    Piquero, Gemma; Vargas-Balbuena, Javier

    2004-01-01

    We provide a simple theoretical study of beams non-uniformly polarized across their transverse sections which can be introduced in undergraduate optics courses. In order to generate such beams we propose to use a slightly convergent (or divergent) linearly and uniformly polarized beam impinging on an anisotropic uniaxial material with the beam propagation direction along the optic axis. Analytical expressions for the Jones vector, Stokes parameters, ellipticity and azimuth at each point of the transverse section, perpendicular to the propagation direction, are obtained at the output of this system. By means of these parameters a detailed description of the state of polarization across the transverse profile is given

  10. Characterizing the spin orbit torque field-like term in in-plane magnetic system using transverse field

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Feilong [School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371 (Singapore); Data Storage Institute, A*STAR Agency for Science, Technology and Research, DSI Building, 5 Engineering Drive 1, Singapore 117608 (Singapore); Goolaup, Sarjoosing; Li, Sihua; Lim, Gerard Joseph; Tan, Funan; Engel, Christian; Zhang, Senfu; Ma, Fusheng; Lew, Wen Siang, E-mail: wensiang@ntu.edu.sg [School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371 (Singapore); Zhou, Tiejun [Data Storage Institute, A*STAR Agency for Science, Technology and Research, DSI Building, 5 Engineering Drive 1, Singapore 117608 (Singapore)

    2016-08-28

    In this work, we present an efficient method for characterizing the spin orbit torque field-like term in an in-plane magnetized system using the harmonic measurement technique. This method does not require a priori knowledge of the planar and anomalous hall resistances and is insensitive to non-uniformity in magnetization, as opposed to the conventional harmonic technique. We theoretically and experimentally demonstrate that the field-like term in the Ta/Co/Pt film stack with in-plane magnetic anisotropy can be obtained by an in-plane transverse field sweep as expected, and magnetization non-uniformity is prevented by the application of fixed magnetic field. The experimental results are in agreement with the analytical calculations.

  11. Radiometric Non-Uniformity Characterization and Correction of Landsat 8 OLI Using Earth Imagery-Based Techniques

    Directory of Open Access Journals (Sweden)

    Frank Pesta

    2014-12-01

    Full Text Available Landsat 8 is the first satellite in the Landsat mission to acquire spectral imagery of the Earth using pushbroom sensor instruments. As a result, there are almost 70,000 unique detectors on the Operational Land Imager (OLI alone to monitor. Due to minute variations in manufacturing and temporal degradation, every detector will exhibit a different behavior when exposed to uniform radiance, causing a noticeable striping artifact in collected imagery. Solar collects using the OLI’s on-board solar diffuser panels are the primary method of characterizing detector level non-uniformity. This paper reports on an approach for using a side-slither maneuver to estimate relative detector gains within each individual focal plane module (FPM in the OLI. A method to characterize cirrus band detector-level non-uniformity using deep convective clouds (DCCs is also presented. These approaches are discussed, and then, correction results are compared with the diffuser-based method. Detector relative gain stability is assessed using the side-slither technique. Side-slither relative gains were found to correct streaking in test imagery with quality comparable to diffuser-based gains (within 0.005% for VNIR/PAN; 0.01% for SWIR and identified a 0.5% temporal drift over a year. The DCC technique provided relative gains that visually decreased striping over the operational calibration in many images.

  12. Modelling of Spring Constant and Pull-down Voltage of Non-uniform RF MEMS Cantilever Incorporating Stress Gradient

    Directory of Open Access Journals (Sweden)

    Shimul Chandra SAHA

    2008-11-01

    Full Text Available We have presented a model for spring constant and pull-down voltage of a non-uniform radio frequency microelectromechanical systems (RF MEMS cantilever that works on electrostatic actuation. The residual stress gradient in the beam material that may arise during the fabrication process is also considered in the model. Using basic force deflection calculation of the suspended beam, a stand-alone model for the spring constant and pull-down voltage of the non-uniform cantilever is developed. To compare the model, simulation is performed using standard Finite Element Method (FEM analysis tolls from CoventorWare. The model matches very well with the FEM simulation results. The model will offer an efficient means of design, analysis, and optimization of RF MEMS cantilever switches.

  13. Devaney's chaos on uniform limit maps

    International Nuclear Information System (INIS)

    Yan Kesong; Zeng Fanping; Zhang Gengrong

    2011-01-01

    Highlights: → The transitivity may not been inherited even if the sequence functions mixing. → The sensitivity may not been inherited even if the iterates of sequence have some uniform convergence. → Some equivalence conditions for the transitivity and sensitivity for uniform limit function are given. → A non-transitive sequence may converge uniformly to a transitive map. - Abstract: Let (X, d) be a compact metric space and f n : X → X a sequence of continuous maps such that (f n ) converges uniformly to a map f. The purpose of this paper is to study the Devaney's chaos on the uniform limit f. On the one hand, we show that f is not necessarily transitive even if all f n mixing, and the sensitive dependence on initial conditions may not been inherited to f even if the iterates of the sequence have some uniform convergence, which correct two wrong claims in . On the other hand, we give some equivalence conditions for the uniform limit f to be transitive and to have sensitive dependence on initial conditions. Moreover, we present an example to show that a non-transitive sequence may converge uniformly to a transitive map.

  14. Chiral and parity symmetry breaking for planar fermions: Effects of a heat bath and uniform external magnetic field

    International Nuclear Information System (INIS)

    Ayala, Alejandro; Bashir, Adnan; Gutierrez, Enif; Raya, Alfredo; Sanchez, Angel

    2010-01-01

    We study chiral symmetry breaking for relativistic fermions, described by a parity-violating Lagrangian in 2+1-dimensions, in the presence of a heat bath and a uniform external magnetic field. Working within their four-component formalism allows for the inclusion of both parity-even and -odd mass terms. Therefore, we can define two types of fermion antifermion condensates. For a given value of the magnetic field, there exist two different critical temperatures which would render one of these condensates identically zero, while the other would survive. Our analysis is completely general: it requires no particular simplifying hierarchy among the energy scales involved, namely, bare masses, field strength, and temperature. However, we do reproduce some earlier results, obtained or anticipated in literature, corresponding to special kinematical regimes for the parity conserving case. Relating the chiral condensate to the one-loop effective Lagrangian, we also obtain the magnetization and the pair production rate for different fermion species in a uniform electric field through the replacement B→-iE.

  15. Effect of annealing, thickness ratio and bend angle on springback of AA6061-T6 with non-uniform thickness section

    Directory of Open Access Journals (Sweden)

    Adnan M.F.

    2017-01-01

    Full Text Available Non-uniform thickness section section is considered one of the most effective approaches to reduce automotive part weight. Reduction in term of mass and size result in less fuel consumption and greenhouse gases. Thickness is the most significant parameter to formability, therefore forming a section with non-uniform thickness becomes a great challenge. Improper process and incorrect decision may lead to severe defect and one of the main concerns is the springback. This study will focus on springback behaviour of non-uniform thickness AA6061 strip with complex profile using Taguchi Method. Profile projector (PC 3000 is used to measure the spring back and two-line technique is applied to measure angles (after loading between two lines. Three parameters (i.e. annealing temperature, thickness ratio and bend angle are studied, and results determine that the most significant parameter is bend angle, followed by thickness ratio, and then by the annealing temperature of the specimen during bending process.

  16. Non-Uniform Free-Free Absorption in the GPS Radio Galaxy 0108+388

    CERN Document Server

    Marr, J M; Crawford, F

    2001-01-01

    We have observed the canonical gigahertz-peaked spectrum source 0108+388 with the VLBA at a range of frequencies above and below the spectral peak. The activity that dominates the radio emission from 0108+388, which is also classified as a Compact Symmetric Object, is thought to be less than 1000 years old. We present strong evidence that the spectral turnover in 0108+388 results from free-free absorption by non-uniform gas, possibly in the form of a disk in the central tens of parsecs.

  17. Behaviour of laser-produced plasma in a uniform magnetic field

    International Nuclear Information System (INIS)

    Okada, Shigefumi; Sato, Kohnosuke; Sekiguchi, Tadashi.

    1979-11-01

    A column of a laser-produced plasma is successfully made in a uniform magnetic field. The radius of the column increases and then decreases (bouncing motion). On the surface of this plasma column, where the steep density gradient exists with the scale length shorter than the ion Larmor radius, an azimuthal modulation appears in the plasma luminosity. This is indicative of the flute-like instability with the azimuthal wave number; k sub(perpendicular) -- 4 x 10 3 B sup(0.8) (in the MKSA system of units). The dispersion equation based on the linearized Vlasov equation with the local approximation is derived and the occurrence of the lower-hybrid-drift instability is predicted. A fairly good agreement between the theory and experiments is seen. (author)

  18. 2> for a scalar field in 2D black holes: A new uniform approximation

    International Nuclear Information System (INIS)

    Frolov, V.; Sushkov, S.V.; Zelnikov, A.

    2003-01-01

    We study nonconformal quantum scalar fields and averages of their local observables (such as 2 > ren and μν > ren ) in the spacetime of a two-dimensional black hole. In order to get an analytical approximation for these expressions the WKB approximation is often used. We demonstrate that at the horizon the WKB approximation is violated for a nonconformal field, that is, when the field mass or/and the parameter of nonminimal coupling does not vanish. We propose a new 'uniform approximation' which solves this problem. We use this approximation to obtain an improved analytical approximation for 2 > ren in the two-dimensional black hole geometry. We compare the results obtained with numerical calculations

  19. The multi-layered ring under parabolic distribution of radial stresses combined with uniform internal and external pressure

    Directory of Open Access Journals (Sweden)

    Christos F. Markides

    2017-04-01

    Full Text Available A recently introduced solution for the stress- and displacement-fields, developed in a multi-layered circular ring, composed of a finite number of linearly elastic concentric layers, subjected to a parabolic distribution of ra-dial stresses, is here extended to encompass a more general loading scheme, closer to actual conditions. The loading scheme includes, besides the para¬-bolic radial stresses, a combination of uniform pressures acting along the outer- and inner- most boundaries of the layered ring. The analytic solution of the problem is achieved by adopting Savin’s pioneering approach for an infinite plate with a hole strengthened by rings. Taking advantage of the results provided by the ana¬lytic solution, a numerical model, simulating the configuration of a three-layered ring (quite commonly encountered in practic¬al applications is validated. The numerical model is then used for a parametric analysis enlightening some crucial aspects of the overall response of the ring.

  20. Uniform irradiation of irregularly shaped cavities for photodynamic therapy.

    Science.gov (United States)

    Rem, A I; van Gemert, M J; van der Meulen, F W; Gijsbers, G H; Beek, J F

    1997-03-01

    It is difficult to achieve a uniform light distribution in irregularly shaped cavities. We have conducted a study on the use of hollow 'integrating' moulds for more uniform light delivery of photodynamic therapy in irregularly shaped cavities such as the oral cavity. Simple geometries such as a cubical box, a sphere, a cylinder and a 'bottle-neck' geometry have been investigated experimentally and the results have been compared with computed light distributions obtained using the 'radiosity method'. A high reflection coefficient of the mould and the best uniform direct irradiance possible on the inside of the mould were found to be important determinants for achieving a uniform light distribution.