WorldWideScience

Sample records for non-seasonal tank model

  1. WWTP Process Tank Modelling

    DEFF Research Database (Denmark)

    Laursen, Jesper

    hydrofoil shaped propellers. These two sub-processes deliver the main part of the supplied energy to the activated sludge tank, and for this reason they are important for the mixing conditions in the tank. For other important processes occurring in the activated sludge tank, existing models and measurements...

  2. Modelling of baffled stirred tanks

    Energy Technology Data Exchange (ETDEWEB)

    Ahlstedt, H.; Lahtinen, M. [Tampere Univ. of Technology (Finland). Energy and Process Engineering

    1996-12-31

    The three-dimensional flow field of a baffled stirred tank has been calculated using four different turbulence models. The tank is driven by a Rushton-type impeller. The boundary condition for the impeller region has been given as a source term or by calculating the impeller using the sliding mesh technique. Calculated values have been compared with measured data. (author)

  3. Tank System Integrated Model: A Cryogenic Tank Performance Prediction Program

    Science.gov (United States)

    Bolshinskiy, L. G.; Hedayat, A.; Hastings, L. J.; Sutherlin, S. G.; Schnell, A. R.; Moder, J. P.

    2017-01-01

    Accurate predictions of the thermodynamic state of the cryogenic propellants, pressurization rate, and performance of pressure control techniques in cryogenic tanks are required for development of cryogenic fluid long-duration storage technology and planning for future space exploration missions. This Technical Memorandum (TM) presents the analytical tool, Tank System Integrated Model (TankSIM), which can be used for modeling pressure control and predicting the behavior of cryogenic propellant for long-term storage for future space missions. Utilizing TankSIM, the following processes can be modeled: tank self-pressurization, boiloff, ullage venting, mixing, and condensation on the tank wall. This TM also includes comparisons of TankSIM program predictions with the test data andexamples of multiphase mission calculations.

  4. TANK48 CFD MODELING ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.

    2011-05-17

    The process of recovering the waste in storage tanks at the Savannah River Site (SRS) typically requires mixing the contents of the tank to ensure uniformity of the discharge stream. Mixing is accomplished with one to four dual-nozzle slurry pumps located within the tank liquid. For the work, a Tank 48 simulation model with a maximum of four slurry pumps in operation has been developed to estimate flow patterns for efficient solid mixing. The modeling calculations were performed by using two modeling approaches. One approach is a single-phase Computational Fluid Dynamics (CFD) model to evaluate the flow patterns and qualitative mixing behaviors for a range of different modeling conditions since the model was previously benchmarked against the test results. The other is a two-phase CFD model to estimate solid concentrations in a quantitative way by solving the Eulerian governing equations for the continuous fluid and discrete solid phases over the entire fluid domain of Tank 48. The two-phase results should be considered as the preliminary scoping calculations since the model was not validated against the test results yet. A series of sensitivity calculations for different numbers of pumps and operating conditions has been performed to provide operational guidance for solids suspension and mixing in the tank. In the analysis, the pump was assumed to be stationary. Major solid obstructions including the pump housing, the pump columns, and the 82 inch central support column were included. The steady state and three-dimensional analyses with a two-equation turbulence model were performed with FLUENT{trademark} for the single-phase approach and CFX for the two-phase approach. Recommended operational guidance was developed assuming that local fluid velocity can be used as a measure of sludge suspension and spatial mixing under single-phase tank model. For quantitative analysis, a two-phase fluid-solid model was developed for the same modeling conditions as the single

  5. SINDA/FLUINT Stratified Tank Modeling for Cryrogenic Propellant Tanks

    Science.gov (United States)

    Sakowski, Barbara

    2014-01-01

    A general purpose SINDA/FLUINT (S/F) stratified tank model was created to simulate self-pressurization and axial jet TVS; Stratified layers in the vapor and liquid are modeled using S/F lumps.; The stratified tank model was constructed to permit incorporating the following additional features:, Multiple or singular lumps in the liquid and vapor regions of the tank, Real gases (also mixtures) and compressible liquids, Venting, pressurizing, and draining, Condensation and evaporation/boiling, Wall heat transfer, Elliptical, cylindrical, and spherical tank geometries; Extensive user logic is used to allow detailed tailoring - Don't have to rebuilt everything from scratch!!; Most code input for a specific case is done through the Registers Data Block:, Lump volumes are determined through user input:; Geometric tank dimensions (height, width, etc); Liquid level could be input as either a volume percentage of fill level or actual liquid level height

  6. Enhanced Waste Tank Level Model

    Energy Technology Data Exchange (ETDEWEB)

    Duignan, M.R.

    1999-06-24

    'With the increased sensitivity of waste-level measurements in the H-Area Tanks and with periods of isolation, when no mass transfer occurred for certain tanks, waste-level changes have been recorded with are unexplained.'

  7. Enhanced Waste Tank Level Model

    Energy Technology Data Exchange (ETDEWEB)

    Duignan, M.R.

    1999-06-24

    'With the increased sensitivity of waste-level measurements in the H-Area Tanks and with periods of isolation, when no mass transfer occurred for certain tanks, waste-level changes have been recorded with are unexplained.'

  8. Numerical Modelling of Flow and Settling in Secondary Settling Tanks

    DEFF Research Database (Denmark)

    Dahl, Claus Poulsen

    This thesis discusses the development of a numerical model for the simulation of secondary settling tanks. In the first part, the status on the development of numerical models for settling tanks and a discussion of the current design practice are presented. A study of the existing numerical models...... and design practice proved a demand for further development to include numerical models in the design of settling tanks, thus improving the future settling tanks....

  9. Numerical Modelling of Flow and Settling in Secondary Settling Tanks

    DEFF Research Database (Denmark)

    Dahl, Claus Poulsen

    This thesis discusses the development of a numerical model for the simulation of secondary settling tanks. In the first part, the status on the development of numerical models for settling tanks and a discussion of the current design practice are presented. A study of the existing numerical models...... and design practice proved a demand for further development to include numerical models in the design of settling tanks, thus improving the future settling tanks....

  10. DETAILED MODELLING OF CHARGING BEHAVIOUR OF SMART SOLAR TANKS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Andersen, Elsa; Furbo, Simon

    2010-01-01

    The charging behaviour of smart solar tanks for solar combisystems for one-family houses is investigated with detailed Computational Fluid Dynamics (CFD) modelling and Particle Image Velocimetry (PIV) measurements. The smart solar tank can be charged with a variable auxiliary volume fitted...... to the expected future energy demand. Therefore the heat loss from the tank is decreased and the thermal performance of the solar heating system is increased compared to a traditional system with a fixed auxiliary volume. The solar tank can be charged either by an electric heating element situated in the tank...... or by an electric heating element in a side-arm mounted on the side of the tank. Detailed CFD models of the smart tanks are built with different mesh densities in the tank and in the side-arm. The thermal conditions of the tank during charging are calculated with the CFD models. The fluid flow and temperature...

  11. DETAILED MODELLING OF CHARGING BEHAVIOUR OF SMART SOLAR TANKS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Andersen, Elsa; Furbo, Simon

    The charging behaviour of smart solar tanks for solar combisystems for one-family houses is investigated with detailed Computational Fluid Dynamics (CFD) modelling and Particle Image Velocimetry (PIV) measurements. The smart solar tank can be charged with a variable auxiliary volume fitted...... to the expected future energy demand. Therefore the heat loss from the tank is decreased and the thermal performance of the solar heating system is increased compared to a traditional system with a fixed auxiliary volume. The solar tank can be charged either by an electric heating element situated in the tank...... or by an electric heating element in a side-arm mounted on the side of the tank. Detailed CFD models of the smart tanks are built with different mesh densities in the tank and in the side-arm. The thermal conditions of the tank during charging are calculated with the CFD models. The fluid flow and temperature...

  12. Computer modeling of ORNL storage tank sludge mobilization and mixing

    Energy Technology Data Exchange (ETDEWEB)

    Terrones, G.; Eyler, L.L.

    1993-09-01

    This report presents and analyzes the results of the computer modeling of mixing and mobilization of sludge in horizontal, cylindrical storage tanks using submerged liquid jets. The computer modeling uses the TEMPEST computational fluid dynamics computer program. The horizontal, cylindrical storage tank configuration is similar to the Melton Valley Storage Tanks (MVST) at Oak Ridge National (ORNL). The MVST tank contents exhibit non-homogeneous, non-Newtonian rheology characteristics. The eventual goals of the simulations are to determine under what conditions sludge mobilization using submerged liquid jets is feasible in tanks of this configuration, and to estimate mixing times required to approach homogeneity of the contents of the tanks.

  13. Development of an energy storage tank model

    Science.gov (United States)

    Buckley, Robert Christopher

    A linearized, one-dimensional finite difference model employing an implicit finite difference method for energy storage tanks is developed, programmed with MATLAB, and demonstrated for different applications. A set of nodal energy equations is developed by considering the energy interactions on a small control volume. The general method of solving these equations is described as are other features of the simulation program. Two modeling applications are presented: the first using a hot water storage tank with a solar collector and an absorption chiller to cool a building in the summer, the second using a molten salt storage system with a solar collector and steam power plant to generate electricity. Recommendations for further study as well as all of the source code generated in the project are also provided.

  14. GEOCHEMICAL TESTING AND MODEL DEVELOPMENT - RESIDUAL TANK WASTE TEST PLAN

    Energy Technology Data Exchange (ETDEWEB)

    CANTRELL KJ; CONNELLY MP

    2010-03-09

    This Test Plan describes the testing and chemical analyses release rate studies on tank residual samples collected following the retrieval of waste from the tank. This work will provide the data required to develop a contaminant release model for the tank residuals from both sludge and salt cake single-shell tanks. The data are intended for use in the long-term performance assessment and conceptual model development.

  15. MODELING ANALYSIS FOR GROUT HOPPER WASTE TANK

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.

    2012-01-04

    The Saltstone facility at Savannah River Site (SRS) has a grout hopper tank to provide agitator stirring of the Saltstone feed materials. The tank has about 300 gallon capacity to provide a larger working volume for the grout nuclear waste slurry to be held in case of a process upset, and it is equipped with a mechanical agitator, which is intended to keep the grout in motion and agitated so that it won't start to set up. The primary objective of the work was to evaluate the flow performance for mechanical agitators to prevent vortex pull-through for an adequate stirring of the feed materials and to estimate an agitator speed which provides acceptable flow performance with a 45{sup o} pitched four-blade agitator. In addition, the power consumption required for the agitator operation was estimated. The modeling calculations were performed by taking two steps of the Computational Fluid Dynamics (CFD) modeling approach. As a first step, a simple single-stage agitator model with 45{sup o} pitched propeller blades was developed for the initial scoping analysis of the flow pattern behaviors for a range of different operating conditions. Based on the initial phase-1 results, the phase-2 model with a two-stage agitator was developed for the final performance evaluations. A series of sensitivity calculations for different designs of agitators and operating conditions have been performed to investigate the impact of key parameters on the grout hydraulic performance in a 300-gallon hopper tank. For the analysis, viscous shear was modeled by using the Bingham plastic approximation. Steady state analyses with a two-equation turbulence model were performed. All analyses were based on three-dimensional results. Recommended operational guidance was developed by using the basic concept that local shear rate profiles and flow patterns can be used as a measure of hydraulic performance and spatial stirring. Flow patterns were estimated by a Lagrangian integration technique along

  16. MODELING ANALYSIS FOR GROUT HOPPER WASTE TANK

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.

    2012-01-04

    The Saltstone facility at Savannah River Site (SRS) has a grout hopper tank to provide agitator stirring of the Saltstone feed materials. The tank has about 300 gallon capacity to provide a larger working volume for the grout nuclear waste slurry to be held in case of a process upset, and it is equipped with a mechanical agitator, which is intended to keep the grout in motion and agitated so that it won't start to set up. The primary objective of the work was to evaluate the flow performance for mechanical agitators to prevent vortex pull-through for an adequate stirring of the feed materials and to estimate an agitator speed which provides acceptable flow performance with a 45{sup o} pitched four-blade agitator. In addition, the power consumption required for the agitator operation was estimated. The modeling calculations were performed by taking two steps of the Computational Fluid Dynamics (CFD) modeling approach. As a first step, a simple single-stage agitator model with 45{sup o} pitched propeller blades was developed for the initial scoping analysis of the flow pattern behaviors for a range of different operating conditions. Based on the initial phase-1 results, the phase-2 model with a two-stage agitator was developed for the final performance evaluations. A series of sensitivity calculations for different designs of agitators and operating conditions have been performed to investigate the impact of key parameters on the grout hydraulic performance in a 300-gallon hopper tank. For the analysis, viscous shear was modeled by using the Bingham plastic approximation. Steady state analyses with a two-equation turbulence model were performed. All analyses were based on three-dimensional results. Recommended operational guidance was developed by using the basic concept that local shear rate profiles and flow patterns can be used as a measure of hydraulic performance and spatial stirring. Flow patterns were estimated by a Lagrangian integration technique along

  17. Tank bromeliad - a natural model ecosystem for methane cycling research

    Science.gov (United States)

    Martinson, Guntars; Brandt, Franziska; Conrad, Ralf

    2014-05-01

    Tank bromeliads are common epiphytes throughout neotropical forest ecosystems. They are relatively small discrete habitats for terrestrial and aquatic macro- and microorganisms and naturally replicated. Their tanks effectively collect leaf litter and water and harbor a diverse microbial community. Up to several thousands of these tank bromeliads per hectare of tropical forest create a unique wetland ecosystem responsible for significant methane emissions. In a field study in tropical montane forests of southern Ecuador we sampled tank bromeliads of different species, size and canopy height and found that tank water availability controlled community composition of methanogenic archaea, determined by molecular analysis of the archaeal 16S rRNA genes. We set up a greenhouse experiment to investigate drying and re-wetting effects on microbial community composition and methanogenesis. Additionally, we conducted 13-CH-4 and 13-CO-2 labeling studies to investigate potential interaction of plant and microbial metabolism during methane cycling in tank bromeliads. Drying resulted in rapid change of the microbial community composition. The relative abundance of acetoclastic methanogens increased and that of hydrogenotrophic methanogens decreased with decreasing tank water availability confirming our field observations. Labeling studies showed that carbon was released from the plant into the tank supporting methanogenesis and that tank-produced methane was ventilated through the bromeliad leaf structure into the atmosphere which is analogous to the rhizosphere environment of wetland ecosystems. The bromeliad ecosystem may therefore provide a natural model to study how environmental changes and plant-microbe interactions drive methane cycling in aquatic-terrestrial ecosystems.

  18. MODELLING MANTLE TANKS FOR SDHW SYSTEMS USING PIV AND CFD

    DEFF Research Database (Denmark)

    Shah, Louise Jivan; Morrison, G.L.; Behnia, Masud

    1999-01-01

    Characteristics of vertical mantle heat exchanger tanks for SDHW systems have been investigated experimentally and theoretically using particle image velocimetry (PIV) and CFD modelling. A glass model of a mantle heat exchanger tank was constructed so that the flow distribution in the mantle could...... be studied using the PIV test facility. Two transient three-dimensional CFD-models of the glass model mantle tank were developed using the CFD-programmes CFX and FLUENT.The experimental results illustrate that the mantle flow structure in the mantle is complicated and the distribution of flow in the mantle...

  19. Mathematical model of the Savannah River Site waste tank farm

    Energy Technology Data Exchange (ETDEWEB)

    Smith, F.G. III.

    1991-07-15

    A mathematical model has been developed to simulate operation of the waste tank farm and the associated evaporator systems at the Savannah River Site. The model solves material balance equations to predict the volumes of liquid waste, salt, and sludge for all of the tanks within each of the evaporator systems. Additional logic is included to model the behavior of waste tanks not directly associated with the evaporators. Input parameters include the Material Management Plan forecast of canyon operations, specification of other waste sources for the evaporator systems, evaporator operating characteristics, and salt and sludge removal schedules. The model determines how the evaporators will operate, when waste transfers can be made, and waste accumulation rates. Output from the model includes waste tank contents, summaries of systems operations, and reports of space gain and the remaining capacity to store waste materials within the tank farm. Model simulations can be made to predict waste tank capacities on a daily basis for up to 20 years. The model is coded as a set of three computer programs designed to run on either IBM compatible or Apple Macintosh II personal computers.

  20. [Study on the quantitative estimation method for VOCs emission from petrochemical storage tanks based on tanks 4.0.9d model].

    Science.gov (United States)

    Li, Jing; Wang, Min-Yan; Zhang, Jian; He, Wan-Qing; Nie, Lei; Shao, Xia

    2013-12-01

    VOCs emission from petrochemical storage tanks is one of the important emission sources in the petrochemical industry. In order to find out the VOCs emission amount of petrochemical storage tanks, Tanks 4.0.9d model is utilized to calculate the VOCs emission from different kinds of storage tanks. VOCs emissions from a horizontal tank, a vertical fixed roof tank, an internal floating roof tank and an external floating roof tank were calculated as an example. The consideration of the site meteorological information, the sealing information, the tank content information and unit conversion by using Tanks 4.0.9d model in China was also discussed. Tanks 4.0.9d model can be used to estimate VOCs emissions from petrochemical storage tanks in China as a simple and highly accurate method.

  1. EM modeling of RF drive in DTL tank 4

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, Sergey S. [Los Alamos National Laboratory

    2012-06-19

    A 3-D MicroWave Studio model for the RF drive in the LANSCE DTL tank 4 has been built. Both eigensolver and time-domain modeling are used to evaluate maximal fields in the drive module and RF coupling. The LANSCE DTL tank 4 has recently been experiencing RF problems, which may or may not be related to its replaced RF coupler. This situation stimulated a request by Dan Rees to provide EM modeling of the RF drive in the DTL tank 4 (T4). Jim O'Hara provided a CAD model that was imported into the CST Microwave Studio (MWS) and after some modifications became a part of a simplified MWS model of the T4 RF drive. This technical note describes the model and presents simulation results.

  2. Numerical modeling of the flow in a cryogenic fuel tank

    Science.gov (United States)

    Greer, Donald Steven

    Developing reusable flight weight cryogenic fuel tanks is one of the technological challenges in designing advanced hypersonic aircraft and the next generation of spacecraft. As an aid in the design of these aircraft, a computational fluid dynamics (CFD) model has been developed specifically for the analysis of flow in a cryogenic fuel tank. The model simulates the transient, two dimensional draining of a fuel tank cross section. The interface between the ullage gas and liquid fuel is modeled as a free surface to enable the calculation of slosh wave dynamics. The drain rate of the liquid fuel is specified as a boundary condition to the model. The ullage gas enters the model to replace the volume of drained liquid. The rate of ullage gas entering the model is calculated from boundary conditions of constant pressure and temperature for the ullage gas. The model employs the full set of Navier-Stokes equations with the exception that viscous dissipation is neglected in the energy equation. The method of solution is an explicit finite difference technique in two dimensional generalized coordinates approximated to second order accuracy in both space and time. The stiffness due to the low Mach number is handled by the method of artificial compressibility. Model comparisons are made to experimental data for free convection to a vertical plate and to free convection inside a horizontal cylinder. Slosh wave dynamics are compared to potential flow calculations for waves inside a square tank. Sample calculations are also performed on a rectangular tank and an eight sided polygon tank to demonstrate the capability of the model.

  3. Thermodynamic models for bounding pressurant mass requirements of cryogenic tanks

    Science.gov (United States)

    Vandresar, Neil T.; Haberbusch, Mark S.

    1994-01-01

    Thermodynamic models have been formulated to predict lower and upper bounds for the mass of pressurant gas required to pressurize a cryogenic tank and then expel liquid from the tank. Limiting conditions are based on either thermal equilibrium or zero energy exchange between the pressurant gas and initial tank contents. The models are independent of gravity level and allow specification of autogenous or non-condensible pressurants. Partial liquid fill levels may be specified for initial and final conditions. Model predictions are shown to successfully bound results from limited normal-gravity tests with condensable and non-condensable pressurant gases. Representative maximum collapse factor maps are presented for liquid hydrogen to show the effects of initial and final fill level on the range of pressurant gas requirements. Maximum collapse factors occur for partial expulsions with large final liquid fill fractions.

  4. Modeling the performance of coated LPG tanks engulfes in fires

    NARCIS (Netherlands)

    Cozzani, V.; Landucci, G.; Molag, M. (Menso)

    2009-01-01

    The improvement of passive fire protection of storage vessels is a key factor to enhance safety among the LPG distribution chain. A thermal and mechanical model based on finite elements simulations was developed to assess the behaviour of full size tanks used for LPG storage and transportation in fi

  5. Modeling the performance of coated LPG tanks engulfed in fires

    NARCIS (Netherlands)

    Landucci, G.; Molag, M.; Cozzani, V.

    2009-01-01

    The improvement of passive fire protection of storage vessels is a key factor to enhance safety among the LPG distribution chain. A thermal and mechanical model based on finite elements simulations was developed to assess the behaviour of full size tanks used for LPG storage and transportation in fi

  6. Correlation models for waste tank sludges and slurries

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, L.A.; Trent, D.S.

    1995-07-01

    This report presents the results of work conducted to support the TEMPEST computer modeling under the Flammable Gas Program (FGP) and to further the comprehension of the physical processes occurring in the Hanford waste tanks. The end products of this task are correlation models (sets of algorithms) that can be added to the TEMPEST computer code to improve the reliability of its simulation of the physical processes that occur in Hanford tanks. The correlation models can be used to augment, not only the TEMPEST code, but other computer codes that can simulate sludge motion and flammable gas retention. This report presents the correlation models, also termed submodels, that have been developed to date. The submodel-development process is an ongoing effort designed to increase our understanding of sludge behavior and improve our ability to realistically simulate the sludge fluid characteristics that have an impact on safety analysis. The effort has employed both literature searches and data correlation to provide an encyclopedia of tank waste properties in forms that are relatively easy to use in modeling waste behavior. These properties submodels will be used in other tasks to simulate waste behavior in the tanks. Density, viscosity, yield strength, surface tension, heat capacity, thermal conductivity, salt solubility, and ammonia and water vapor pressures were compiled for solutions and suspensions of sodium nitrate and other salts (where data were available), and the data were correlated by linear regression. In addition, data for simulated Hanford waste tank supernatant were correlated to provide density, solubility, surface tension, and vapor pressure submodels for multi-component solutions containing sodium hydroxide, sodium nitrate, sodium nitrite, and sodium aluminate.

  7. Computer Modelling of a Tank Battle with Helicopter Support

    Directory of Open Access Journals (Sweden)

    Chatter Singh

    1986-01-01

    Full Text Available The paper attempts to model a tank versus tank battle scenario in which the defender is provided an armed helicopter unit support, against surprise advance of the attacker towards an important place. The stochastic and dynamic nature of the battle system has been handled by means of Monte Carlo simulation. In that activities like move, search, fire, hit and kill are simulated and their effects generated in the model. The game has been repeated for parameters relating to (i fire power (ii mobility (iii intervisibility (iv blind shooting (v defender/attacker force ratio and (vi helicopter unit support with the defender. Then, average numerical effects in each case have been analysed.Although the results are based on tentative data, the. trend seems to suggest that a battalion of Centurion tanks or 2 coys with a helicopter unit support stand fairly good chance to defeat the attack by M-47/48 tanks equivalent to 4 coys. Neyertheless, the methodology provides an effective basis to systematically approach realistic situations and quantitatively assess weapon systems effectiveness under tactical alternatives and battle field environments.

  8. Modeling and Simulation of a Modified Quadruple Tank System

    DEFF Research Database (Denmark)

    Mohd. Azam, Sazuan Nazrah; Jørgensen, John Bagterp

    2015-01-01

    Quadruple tank process is a non-linear system, have multiple manipulated and controlled variables and have significant cross binding parameters. Furthermore, the modified system is affected by some unknown measurement noise and stochastic disturbance variables which make it more complicated...... to model and control. In this paper, a modified quadruple-tank system has been described, all the important variables has been outlined and a mathematical model has been presented. We developed deterministic and stochastic models using differential equations and simulate the models using Matlab....... Subsequently, steady state analysis is included to determine the operating window for the set points. The purpose to have an operating window for the system is to distinguish the range of feasible region to select the set points for optimum operations. Therefore, in this paper a virtual process plant...

  9. PORFLOW Modeling Supporting The H-Tank Farm Performance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, J. M.; Flach, G. P.; Westbrook, M. L.

    2012-08-31

    Numerical simulations of groundwater flow and contaminant transport in the vadose and saturated zones have been conducted using the PORFLOW code in support of an overall Performance Assessment (PA) of the H-Tank Farm. This report provides technical detail on selected aspects of PORFLOW model development and describes the structure of the associated electronic files. The PORFLOW models for the H-Tank Farm PA, Rev. 1 were updated with grout, solubility, and inventory changes. The aquifer model was refined. In addition, a set of flow sensitivity runs were performed to allow flow to be varied in the related probabilistic GoldSim models. The final PORFLOW concentration values are used as input into a GoldSim dose calculator.

  10. Modelization of a water tank including a PCM module

    Energy Technology Data Exchange (ETDEWEB)

    Ibanez, Manuel [Dept. de Medi Ambient i Ciencies del Sol, Universitat de Lleida, Rovira Roure 191, 25198 Lleida (Spain); Cabeza, Luisa F.; Sole, Cristian; Roca, Joan; Nogues, Miquel [Dept. d' Informatica i Eng. Industrial, Universitat de Lleida, Jaume II 69, 25001 Lleida (Spain)

    2006-08-15

    The reduction of CO{sub 2} emissions is a key component for today's governments. Therefore, implementation of more and more systems with renewable energies is necessary. Solar systems for single family houses or residential buildings need a big water tank that many times is not easy to locate. This paper studies the modelization of a new technology where PCM modules are implemented in domestic hot water tanks to reduce their size without reducing the energy stored. A new TRNSYS component, based in the already existing TYPE 60, was developed, called TYPE 60PCM. After tuning the new component with experimental results, two more experiences were developed to validate the simulation of a water tank with two cylindrical PCM modules using type 60PCM, the cooldown and reheating experiments. Concordance between experimental and simulated data was very good. Since the new TRNSYS component was developed to simulate full solar systems, comparison of experimental results from a pilot plant solar system with simulations were performed, and they confirmed that the type 60PCM is a powerful tool to evaluate the performance of PCM modules in water tanks. (author)

  11. Modeling of Liquefaction of Cryogenic Propellant in a Tank

    Science.gov (United States)

    Hedayat, A.; Bolshinskiy, L. G.; Majumdar, A. K.

    2017-01-01

    Over the past decades NASA has been focusing to develop technology that would to allow for production of cryogenic propellants on the surface of Mars. The in-situ propellant production reduces the amount of propellants needed to be taken to Mars and ultimately to reduce mission cost. Utilizing Martian resources, the produced gaseous propellants (i.e., oxygen and methane) are liquefied and stored prior to use on the Mars ascent vehicle. In this paper, a model for the liquefaction process of gaseous propellants in a cryogenically refrigerated tank is presented. The tank is considered to be cylindrical with elliptical top and bottom domes. A multi-node transient model is developed based on the mass and energy conservation equations and wall-gas and liquid-gas interface mass and heat transfer correlations. Description of the model and predicted results will be presented in the final paper.

  12. Rogue waves in a water tank: Experiments and modeling

    Science.gov (United States)

    Lechuga, Antonio

    2013-04-01

    Recently many rogue waves have been reported as the main cause of ship incidents on the sea. One of the main characteristics of rogue waves is its elusiveness: they present unexpectedly and disappear in the same wave. Some authors (Zakharov and al.2010) are attempting to find the probability of their appearances apart from studyingthe mechanism of the formation. As an effort on this topic we tried the generation of rogue waves in a water wave tank using a symmetric spectrum(Akhmediev et al. 2011) as input on the wave maker. The produced waves were clearly rogue waves with a rate (maximum wave height/ Significant wave height) of 2.33 and a kurtosis of 4.77 (Janssen 2003, Onorato 2006). These results were already presented (Lechuga 2012). Similar waves (in pattern aspect, but without being extreme waves) were described as crossing waves in a water tank(Shemer and Lichter1988). To go on further the next step has been to apply a theoretical model to the envelope of these waves. After some considerations the best model has been an analogue of the Ginzburg-Landau equation. This apparently amazing result is easily explained: We know that the Ginzburg-Landau model is related to some regular structures on the surface of a liquid and also in plasmas, electric and magnetic fields and other media. Another important characteristic of the model is that their solutions are invariants with respectto the translation group. The main aim of this presentation is to extract conclusions of the model and the comparison with the measured waves in the water tank.The nonlinear structure of waves and their regularity make suitable the use of the Ginzburg-Landau model to the envelope of generated waves in the tank,so giving us a powerful tool to cope with the results of our experiment.

  13. Hanford Tank 241-C-103 Residual Waste Contaminant Release Models and Supporting Data

    Energy Technology Data Exchange (ETDEWEB)

    Cantrell, Kirk J.; Krupka, Kenneth M.; Deutsch, William J.; Lindberg, Michael J.; Schaef, Herbert T.; Geiszler, Keith N.; Arey, Bruce W.

    2008-01-15

    This report tabulates data generated by laboratory characterization and testing of three samples collected from tank C-103. The data presented here will form the basis for a release model that will be developed for tank C-103. These release models are being developed to support the tank risk assessments performed by CH2M HILL Hanford Group, Inc. for DOE.

  14. Modelling and test of aeration tank settling (ATS)

    DEFF Research Database (Denmark)

    Nielsen, M. K.; Bechmann, H.; Henze, Mogens

    2000-01-01

    that a qualitatively correct model can be established. The simplicity of the model allows for on-line identification of the necessary parameters, so that no maintenance is needed to use of the on-line model for control. The practical implementation on three plants indicates that implementation of STAR with ATS control......The use of aeration tank settling during high hydraulic loads on large wastewater treatment plants has previously been demonstrated as a reliable technique and proven valuable. The paper proposes a simplified deterministic model to predict the efficiency of the method. It is shown...

  15. Genome-wide analysis of positively selected genes in seasonal and non-seasonal breeding species.

    Directory of Open Access Journals (Sweden)

    Yuhuan Meng

    Full Text Available Some mammals breed throughout the year, while others breed only at certain times of year. These differences in reproductive behavior can be explained by evolution. We identified positively-selected genes in two sets of species with different degrees of relatedness including seasonal and non-seasonal breeding species, using branch-site models. After stringent filtering by sum of pairs scoring, we revealed that more genes underwent positive selection in seasonal compared with non-seasonal breeding species. Positively-selected genes were verified by cDNA mapping of the positive sites with the corresponding cDNA sequences. The design of the evolutionary analysis can effectively lower the false-positive rate and thus identify valid positive genes. Validated, positively-selected genes, including CGA, DNAH1, INVS, and CD151, were related to reproductive behaviors such as spermatogenesis and cell proliferation in non-seasonal breeding species. Genes in seasonal breeding species, including THRAP3, TH1L, and CMTM6, may be related to the evolution of sperm and the circadian rhythm system. Identification of these positively-selected genes might help to identify the molecular mechanisms underlying seasonal and non-seasonal reproductive behaviors.

  16. Computational Fluid Dynamics Modelling of Hydraulics and Sedimentation in Process Reactors during Aeration Tank Settling

    DEFF Research Database (Denmark)

    Jensen, M.D.; Ingildsen, P.; Rasmussen, Michael R.;

    2006-01-01

    Aeration tank settling is a control method allowing settling in the process tank during highhydraulic load. The control method is patented. Aeration tank settling has been applied in several wastewater treatment plants using the present design of the process tanks. Some process tank designs...... haveshown to be more effective than others. To improve the design of less effective plants, computational fluiddynamics (CFD) modelling of hydraulics and sedimentation has been applied. This paper discusses theresults at one particular plant experiencing problems with partly short-circuiting of the inlet...... and outletcausing a disruption of the sludge blanket at the outlet and thereby reducing the retention of sludge in theprocess tank. The model has allowed us to establish a clear picture of the problems arising at the plantduring aeration tank settling. Secondly, several process tank design changes have been...

  17. Stochastically modeling Listeria monocytogenes growth in farm tank milk.

    Science.gov (United States)

    Albert, Isabelle; Pouillot, Régis; Denis, Jean-Baptiste

    2005-10-01

    This article presents a Listeria monocytogenes growth model in milk at the farm bulk tank stage. The main objective was to judge the feasibility and value to risk assessors of introducing a complex model, including a complete thermal model, within a microbial quantitative risk assessment scheme. Predictive microbiology models are used under varying temperature conditions to predict bacterial growth. Input distributions are estimated based on data in the literature, when it is available. If not, reasonable assumptions are made for the considered context. Previously published results based on a Bayesian analysis of growth parameters are used. A Monte Carlo simulation that forecasts bacterial growth is the focus of this study. Three scenarios that take account of the variability and uncertainty of growth parameters are compared. The effect of a sophisticated thermal model taking account of continuous variations in milk temperature was tested by comparison with a simplified model where milk temperature was considered as constant. Limited multiplication of bacteria within the farm bulk tank was modeled. The two principal factors influencing bacterial growth were found to be tank thermostat regulation and bacterial population growth parameters. The dilution phenomenon due to the introduction of new milk was the main factor affecting the final bacterial concentration. The results show that a model that assumes constant environmental conditions at an average temperature should be acceptable for this process. This work may constitute a first step toward exposure assessment for L. monocytogenes in milk. In addition, this partly conceptual work provides guidelines for other risk assessments where continuous variation of a parameter needs to be taken into account.

  18. Modified Mathematical Model For Neutralization System In Stirred Tank Reactor

    Directory of Open Access Journals (Sweden)

    Ahmmed Saadi Ibrehem

    2011-05-01

    Full Text Available A modified model for the neutralization process of Stirred Tank Reactors (CSTR reactor is presented in this study. The model accounts for the effect of strong acid [HCL] flowrate and strong base [NaOH] flowrate with the ionic concentrations of [Cl-] and [Na+] on the Ph of the system. In this work, the effect of important reactor parameters such as ionic concentrations and acid and base flowrates on the dynamic behavior of the CSTR is investigated and the behavior of mathematical model is compared with the reported models for the McAvoy model and Jutila model. Moreover, the results of the model are compared with the experimental data in terms of pH dynamic study. A good agreement is observed between our model prediction and the actual plant data. © 2011 BCREC UNDIP. All rights reserved(Received: 1st March 2011, Revised: 28th March 2011; Accepted: 7th April 2011[How to Cite: A.S. Ibrehem. (2011. Modified Mathematical Model For Neutralization System In Stirred Tank Reactor. Bulletin of Chemical Reaction Engineering & Catalysis, 6(1: 47-52. doi:10.9767/bcrec.6.1.825.47-52][How to Link / DOI: http://dx.doi.org/10.9767/bcrec.6.1.825.47-52 || or local:  http://ejournal.undip.ac.id/index.php/bcrec/article/view/825 ] | View in 

  19. SAMPLE AOR CALCULATION USING ANSYS AXISYMMETRIC PARAMETRIC MODEL FOR TANK SST-A

    Energy Technology Data Exchange (ETDEWEB)

    JULYK, L.J.; MACKEY, T.C.

    2003-06-19

    This document documents the ANSYS axisymmetric parametric model for single-shell tank A and provides sample calculation for analysis-of-record mechanical load conditions. The purpose of this calculation is to develop a parametric model for single shell tank (SST) A, and provide a sample analysis of SST-A tank based on analysis of record (AOR) loads. The SST-A model is based on buyer-supplied as-built drawings and information for the AOR for SSTs, encompassing the existing tank load conditions, and evaluates stresses and deformations throughout the tank and surrounding soil mass.

  20. SAMPLE AOR CALCULATION USING ANSYS AXISYMMETRIC PARAMETRIC MODEL FOR TANK SST-SX

    Energy Technology Data Exchange (ETDEWEB)

    JULYK, L.J.; MACKEY, T.C.

    2003-06-19

    This document documents the ANSYS axisymmetric parametric model for single-shell tank SX and provides sample calculation for analysis-of-record mechanical load conditions. The purpose of this calculation is to develop a parametric model for single shell tank (SST) SX, and provide a sample analysis of the SST-SX tank based on analysis of record (AOR) loads. The SST-SX model is based on buyer-supplied as-built drawings and information for the AOR for SSTs, encompassing the existing tank load conditions, and evaluates stresses and deformations throughout the tank and surrounding soil mass.

  1. SAMPLE AOR CALCULATION USING ANSYS AXISYMMETRIC PARAMETRIC MODEL FOR TANK SST-S

    Energy Technology Data Exchange (ETDEWEB)

    JULYK, L.J.; MACKEY, T.C.

    2003-06-19

    This document documents the ANSYS axisymmetric parametric model for single-shell tank S and provides sample calculation for analysis-of-record mechanical load conditions. The purpose of this calculation is to develop a parametric model for single shell tank (SST) S, and provide a sample analysis of SST-S tank based on analysis of record (AOR) loads. The SST-S model is based on buyer-supplied as-built drawings and information for the AOR for SSTs, encompassing the existing tank load conditions, and evaluates stresses and deformations throughout the tank and surrounding soil mass.

  2. Relative importance of secondary settling tank models in WWTP simulations

    DEFF Research Database (Denmark)

    Ramin, Elham; Flores-Alsina, Xavier; Sin, Gürkan

    2012-01-01

    Results obtained in a study using the Benchmark Simulation Model No. 1 (BSM1) show that a one-dimensional secondary settling tank (1-D SST) model structure and its parameters are among the most significant sources of uncertainty in wastewater treatment plant (WWTP) simulations [Ramin et al., 2011......]. The sensitivity results consistently indicate that the prediction of sludge production is most sensitive to the variation of the settling parameters. In the present study, we use the Benchmark Simulation Model No. 2 (BSM2), a plant-wide benchmark, that combines the Activated Sludge Model No. 1 (ASM1......) with the Anaerobic Digestion Model No. 1 (ADM1). We use BSM2 as a vehicle to compare two different 1-D SST models, and to assess the relative significance of their performance on WWTP simulation model outputs. The two 1-D SST models assessed include the firstorder model by Takács et al. [1991] and the second...

  3. Rogue waves in a wave tank: experiments and modeling

    Directory of Open Access Journals (Sweden)

    A. Lechuga

    2013-07-01

    Full Text Available In past decades theoretical studies have been carried out with the double aim of improving the knowledge of rogue wave main characteristics and of attempting to predict its sudden appearance. As an effort on this topic we tried the generation of rogue waves in a water wave tank using a symmetric spectrum (Akhmediev et al., 2011a as input on the wave maker. To go on further the next step has been to apply a theoretical model to the envelope of these waves. After some considerations the best model has been an analogue of the Ginzburg–Landau equation.

  4. Development of RF System Model for CERN Linac2 Tanks

    CERN Document Server

    Joshi, G; Vretenar, M; Kumar, G; Agarwal, V

    2010-01-01

    An RF system model has been created for the CERN Linac2 Tanks. RF systems in this linac have both single and double feed architectures. The main elements of these systems are: RF power amplifier, main resonator, feed-line and the amplitude and phase feedback loops. The model of the composite system is derived by suitably concatenating the models of these individual sub-systems. For computational efficiency the modeling has been carried out in the base band. The signals are expressed in in-phase - quadrature domain, where the response of the resonator is expressed using two linear differential equations, making it valid for large signal conditions. MATLAB/SIMULINK has been used for creating the model. The model has been found useful in predicting the system behaviour, especially during the transients. In the paper we present the details of the model, highlighting the methodology, which could be easily extended to multiple feed RF systems.

  5. Tank waste remediation system simulation analysis retrieval model

    Energy Technology Data Exchange (ETDEWEB)

    Fordham, R.A.

    1996-09-30

    The goal of simulation was to test tll(., consequences of assumptions. For the TWRS SIMAN Retrieval Model, l@lie specific assumptions are primarily defined with respect to waste processing arid transfer timing. The model tracks 73 chem1913ical constituents from underground waste tanks to glass; yet, the detailed (@hemistrv and complete set of unit operations of the TWRS process flow sheet are represented only at the level necessary to define the waste processing and transfer logic and to estimate the feed composition for the treatment facilities. Tlierefor(,, the model should net be regarded as a substitute for the TWRS process flow sheet. Pra(!ticallv the model functions as a dyrt(imic extension of the flow sheet model. I I The following sections present the description, assunipt@ions, architecture, arid evalua- tion of the TWRS SIMAN Retrieval Model. Section 2 describes the model in terms of an overview of the processes represented. Section 3 presents the assumptions for the simulation model. Specific assumptions 9.tt(l parameter values used in the model are provided for waste retrieval, pretreatment, low-level waste (LLNN7) immobilization, and high-level waste (HLW) immobilization functions. Section 4 describes the model in terms of its functional architec- rare to d(@fine a basis for a systematic evaluation of the model. Finally, Section 5 documents an independent test and evaluation of the niodel`s performance (i.e., the verification and validation). Additionally, Appendix A gives a complete listing of the tank inventory used. Appendix B documents the verification and validation plan that was used for the (Section 5) evaluation work. A description and listing of all the model variables is given in Appendix C along with a complete source listing.

  6. Modeling the performance of coated LPG tanks engulfed in fires

    Energy Technology Data Exchange (ETDEWEB)

    Landucci, Gabriele [CONPRICI - Dipartimento di Ingegneria Chimica, Chimica Industriale e Scienza dei Materiali, Universita di Pisa, via Diotisalvi n.2, 56126 Pisa (Italy); Molag, Menso [Nederlandse Organisatie voor toegepast-natuurwetenschappelijk onderzoek TNO, Princetonlaan 6, 3584 CB Utrecht (Netherlands); Cozzani, Valerio, E-mail: valerio.cozzani@unibo.it [CONPRICI - Dipartimento di Ingegneria Chimica, Mineraria e delle Tecnologie Ambientali, Alma Mater Studiorum - Universita di Bologna, Via Terracini 28 - 40131 Bologna (Italy)

    2009-12-15

    The improvement of passive fire protection of storage vessels is a key factor to enhance safety among the LPG distribution chain. A thermal and mechanical model based on finite elements simulations was developed to assess the behaviour of full size tanks used for LPG storage and transportation in fire engulfment scenarios. The model was validated by experimental results. A specific analysis of the performance of four different reference coating materials was then carried out, also defining specific key performance indicators (KPIs) to assess design safety margins in near-miss simulations. The results confirmed the wide influence of coating application on the expected vessel time to failure due to fire engulfment. A quite different performance of the alternative coating materials was evidenced. General correlations were developed among the vessel time to failure and the effective coating thickness in full engulfment scenarios, providing a preliminary assessment of the coating thickness required to prevent tank rupture for a given time lapse. The KPIs defined allowed the assessment of the available safety margins in the reference scenarios analyzed and of the robustness of thermal protection design.

  7. Modeling the performance of coated LPG tanks engulfed in fires.

    Science.gov (United States)

    Landucci, Gabriele; Molag, Menso; Cozzani, Valerio

    2009-12-15

    The improvement of passive fire protection of storage vessels is a key factor to enhance safety among the LPG distribution chain. A thermal and mechanical model based on finite elements simulations was developed to assess the behaviour of full size tanks used for LPG storage and transportation in fire engulfment scenarios. The model was validated by experimental results. A specific analysis of the performance of four different reference coating materials was then carried out, also defining specific key performance indicators (KPIs) to assess design safety margins in near-miss simulations. The results confirmed the wide influence of coating application on the expected vessel time to failure due to fire engulfment. A quite different performance of the alternative coating materials was evidenced. General correlations were developed among the vessel time to failure and the effective coating thickness in full engulfment scenarios, providing a preliminary assessment of the coating thickness required to prevent tank rupture for a given time lapse. The KPIs defined allowed the assessment of the available safety margins in the reference scenarios analyzed and of the robustness of thermal protection design.

  8. Sensitivity analysis of the secondary settling tank double-exponential function model

    NARCIS (Netherlands)

    Abusam, A.; Keesman, K.J.

    2002-01-01

    The secondary settling tank plays a very crucial role in achieving the very strict effluent standards of wastewater treatment plants. To investigate the ability of the widely used secondary settling tank model, the double-exponential model, to predict the dynamic behavior, a factorial sensitivity an

  9. Hanford Tank 241-C-106: Residual Waste Contaminant Release Model and Supporting Data

    Energy Technology Data Exchange (ETDEWEB)

    Deutsch, William J.; Krupka, Kenneth M.; Lindberg, Michael J.; Cantrell, Kirk J.; Brown, Christopher F.; Schaef, Herbert T.

    2005-06-03

    CH2M HILL is producing risk/performance assessments to support the closure of single-shell tanks at the DOE's Hanford Site. As part of this effort, staff at PNNL were asked to develop release models for contaminants of concern that are present in residual sludge remaining in tank 241-C-106 (C-106) after final retrieval of waste from the tank. This report provides the information developed by PNNL.

  10. Numerical Modeling of Pressurization of a Propellant Tank

    Science.gov (United States)

    Majumdar, Alok; Steadman, Todd

    1999-01-01

    An unsteady finite volume procedure has been developed to predict the history o pressure, temperature and mass flow rate of the pressurant and propellant during the expulsion of the propellant from a tan. The time dependent mass, momentum and energy conservation equations are solved at the ullage space. The model accounts for the change in the ullage volume due to expulsion of the propellant. It also accounts for the heat transfer from the tank wall and propellant to the ullage gas. The procedure was incorporated in the Generalized Fluid System Simulation Program (GFSSP). The results of several test cases were then compared with a published correlation of pressurant requirements for a given displacement of propellant. The agreement between the predictions and the correlation was found to be satisfactory.

  11. Experimental Validation of a Domestic Stratified Hot Water Tank Model in Modelica for Annual Performance Assessment

    DEFF Research Database (Denmark)

    Carmo, Carolina; Dumont, Olivier; Nielsen, Mads Pagh

    2015-01-01

    The use of stratified hot water tanks in solar energy systems - including ORC systems - as well as heat pump systems is paramount for a better performance of these systems. However, the availability of effective and reliable models to predict the annual performance of stratified hot water tanks c...

  12. Analysis of nonlinear shallow water waves in a tank by concentrated mass model

    Science.gov (United States)

    Ishikawa, Satoshi; Kondou, Takahiro; Matsuzaki, Kenichiro; Yamamura, Satoshi

    2016-06-01

    The sloshing of liquid in a tank is an important engineering problem. For example, liquid storage tanks in industrial facilities can be damaged by earthquakes, and conversely liquid tanks, called tuned liquid damper, are often used as passive mechanical dampers. The water depth is less often than the horizontal length of the tank. In this case, shallow water wave theory can be applied, and the results indicate that the surface waveform in a shallow excited tank exhibits complex behavior caused by nonlinearity and dispersion of the liquid. This study aims to establish a practical analytical model for this phenomenon. A model is proposed that consists of masses, connecting nonlinear springs, connecting dampers, base support dampers, and base support springs. The characteristics of the connecting nonlinear springs are derived from the static and dynamic pressures. The advantages of the proposed model are that nonlinear dispersion is considered and that the problem of non-uniform water depth can be addressed. To confirm the validity of the model, numerical results obtained from the model are compared with theoretical values of the natural frequencies of rectangular and triangular tanks. Numerical results are also compared with experimental results for a rectangular tank. All computational results agree well with the theoretical and experimental results. Therefore, it is concluded that the proposed model is valid for the numerical analysis of nonlinear shallow water wave problems.

  13. COMPUTATIONAL FLUID DYNAMICS MODELING OF SCALED HANFORD DOUBLE SHELL TANK MIXING - CFD MODELING SENSITIVITY STUDY RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    JACKSON VL

    2011-08-31

    The primary purpose of the tank mixing and sampling demonstration program is to mitigate the technical risks associated with the ability of the Hanford tank farm delivery and celtification systems to measure and deliver a uniformly mixed high-level waste (HLW) feed to the Waste Treatment and Immobilization Plant (WTP) Uniform feed to the WTP is a requirement of 24590-WTP-ICD-MG-01-019, ICD-19 - Interface Control Document for Waste Feed, although the exact definition of uniform is evolving in this context. Computational Fluid Dynamics (CFD) modeling has been used to assist in evaluating scaleup issues, study operational parameters, and predict mixing performance at full-scale.

  14. Modelling of U-tube Tanks for ShipMo3D Ship Motion Predictions

    Science.gov (United States)

    2012-01-01

    intentionally left blank. ii DRDC Atlantic ECR 2011-300 Executive summary Modelling of U-tube Tanks for ShipMo3D Ship Motion Predictions Kevin McTaggart... ECR 2011-300 iii Sommaire Modelling of U-tube Tanks for ShipMo3D Ship Motion Predictions Kevin McTaggart ; DRDC Atlantic ECR 2011-300 ; Recherche et...Direction, Generic Frigate at 10 knots in Sea State 5, Different U-tube Tank Duct Heights DRDC Atlantic ECR 2011-300 19 6 Conclusions Modelling of U-tube

  15. Simulation model of stratified thermal energy storage tank using finite difference method

    Science.gov (United States)

    Waluyo, Joko

    2016-06-01

    Stratified TES tank is normally used in the cogeneration plant. The stratified TES tanks are simple, low cost, and equal or superior in thermal performance. The advantage of TES tank is that it enables shifting of energy usage from off-peak demand for on-peak demand requirement. To increase energy utilization in a stratified TES tank, it is required to build a simulation model which capable to simulate the charging phenomenon in the stratified TES tank precisely. This paper is aimed to develop a novel model in addressing the aforementioned problem. The model incorporated chiller into the charging of stratified TES tank system in a closed system. The model was developed in one-dimensional type involve with heat transfer aspect. The model covers the main factors affect to degradation of temperature distribution namely conduction through the tank wall, conduction between cool and warm water, mixing effect on the initial flow of the charging as well as heat loss to surrounding. The simulation model is developed based on finite difference method utilizing buffer concept theory and solved in explicit method. Validation of the simulation model is carried out using observed data obtained from operating stratified TES tank in cogeneration plant. The temperature distribution of the model capable of representing S-curve pattern as well as simulating decreased charging temperature after reaching full condition. The coefficient of determination values between the observed data and model obtained higher than 0.88. Meaning that the model has capability in simulating the charging phenomenon in the stratified TES tank. The model is not only capable of generating temperature distribution but also can be enhanced for representing transient condition during the charging of stratified TES tank. This successful model can be addressed for solving the limitation temperature occurs in charging of the stratified TES tank with the absorption chiller. Further, the stratified TES tank can be

  16. Numerical Modeling of Pressurization of Cryogenic Propellant Tank for Integrated Vehicle Fluid System

    Science.gov (United States)

    Majumdar, Alok K.; LeClair, Andre C.; Hedayat, Ali

    2016-01-01

    This paper presents a numerical model of pressurization of a cryogenic propellant tank for the Integrated Vehicle Fluid (IVF) system using the Generalized Fluid System Simulation Program (GFSSP). The IVF propulsion system, being developed by United Launch Alliance, uses boiloff propellants to drive thrusters for the reaction control system as well as to run internal combustion engines to develop power and drive compressors to pressurize propellant tanks. NASA Marshall Space Flight Center (MSFC) has been running tests to verify the functioning of the IVF system using a flight tank. GFSSP, a finite volume based flow network analysis software developed at MSFC, has been used to develop an integrated model of the tank and the pressurization system. This paper presents an iterative algorithm for converging the interface boundary conditions between different component models of a large system model. The model results have been compared with test data.

  17. Models for recurrent gas release event behavior in hazardous waste tanks

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, D.N. [Pacific Northwest Lab., Richland, WA (United States); Arnold, B.C. [California Univ., Riverside, CA (United States). Dept. of Statistics

    1994-08-01

    Certain radioactive waste storage tanks at the United States Department of Energy Hanford facilities continuously generate gases as a result of radiolysis and chemical reactions. The congealed sludge in these tanks traps the gases and causes the level of the waste within the tanks to rise. The waste level continues to rise until the sludge becomes buoyant and ``rolls over``, changing places with heavier fluid on top. During a rollover, the trapped gases are released, resulting, in a sudden drop in the waste level. This is known as a gas release event (GRE). After a GRE, the wastes leading to another GRE. We present nonlinear time waste re-congeals and gas again accumulates leading to another GRE. We present nonlinear time series models that produce simulated sample paths that closely resemble the temporal history of waste levels in these tanks. The models also imitate the random GRE, behavior observed in the temporal waste level history of a storage tank. We are interested in using the structure of these models to understand the probabilistic behavior of the random variable ``time between consecutive GRE`s``. Understanding the stochastic nature of this random variable is important because the hydrogen and nitrous oxide gases released from a GRE, are flammable and the ammonia that is released is a health risk. From a safety perspective, activity around such waste tanks should be halted when a GRE is imminent. With credible GRE models, we can establish time windows in which waste tank research and maintenance activities can be safely performed.

  18. COMPARISON OF EXPERIMENTAL RESULTS TO CFD MODELS FOR BLENDING IN A TANK USING DUAL OPPOSING JETS

    Energy Technology Data Exchange (ETDEWEB)

    Leishear, R.

    2011-08-07

    Research has been completed in a pilot scale, eight foot diameter tank to investigate blending, using a pump with dual opposing jets. The jets re-circulate fluids in the tank to promote blending when fluids are added to the tank. Different jet diameters and different horizontal and vertical orientations of the jets were investigated. In all, eighty five tests were performed both in a tank without internal obstructions and a tank with vertical obstructions similar to a tube bank in a heat exchanger. These obstructions provided scale models of several miles of two inch diameter, serpentine, vertical cooling coils below the liquid surface for a full scale, 1.3 million gallon, liquid radioactive waste storage tank. Two types of tests were performed. One type of test used a tracer fluid, which was homogeneously blended into solution. Data were statistically evaluated to determine blending times for solutions of different density and viscosity, and the blending times were successfully compared to computational fluid dynamics (CFD) models. The other type of test blended solutions of different viscosity. For example, in one test a half tank of water was added to a half tank of a more viscous, concentrated salt solution. In this case, the fluid mechanics of the blending process was noted to significantly change due to stratification of fluids. CFD models for stratification were not investigated. This paper is the fourth in a series of papers resulting from this research (Leishear, et.al. [1- 4]), and this paper documents final test results, statistical analysis of the data, a comparison of experimental results to CFD models, and scale-up of the results to a full scale tank.

  19. Mathematical Model Based on BP Neural Network Algorithm for the Deflection Identification of Storage Tank and Calibration of Tank Capacity Chart

    Directory of Open Access Journals (Sweden)

    Caihong Li

    2013-01-01

    Full Text Available The tank capacity chart calibration problem of two oil tanks with deflection was studied, one of which is an elliptical cylinder storage tank with two truncated ends and another is a cylinder storage tank with two spherical crowns. Firstly, the function relation between oil reserve and oil height based on the integral method was precisely deduced, when the storage tank has longitudinal inclination but has no deflection. Secondly, the nonlinear optimization model which has both longitudinal inclination parameter α and lateral deflection parameter β was constructed, using cut-complement method and approximate treatment method. Then the deflection tank capacity chart calibration with a 10 cm oil level height interval was worked out. Lastly, the tank capacity chart was corrected by BP neural network algorithm and got proportional error of theoretical and experimental measurements ranges from 0% to 0.00015%. Experimental results demonstrated that the proposed method has better performance in terms of tank capacity chart calibration accuracy compared with other existing approaches and has a strongly practical significance.

  20. A model to predict solar heat gains to outside wine tanks

    Energy Technology Data Exchange (ETDEWEB)

    Delves, T.; Weedon, M.; Louis, J. [Charles Sturt Univ., Wagga Wagga, NSW (Australia). National Wine and Grape Industry Centre

    2006-07-01

    Although there are many software and simulation tools for calculating solar heat gains to residential and commercial buildings, little information is available to predict the heating effect of products stored in outdoor facilities. In older wineries where wine is stored outdoors in stainless steel tanks, solar heat gains can result in unwanted warming of the wine. This not only ruins the wine quality, but places an additional load on the winery refrigeration system. In this study, experiments were performed to determine the effect of solar radiation and ambient conditions on the heating of wine stored in outside tanks. Trials were conducted on a 25 kL outdoor stainless steel tank at Rutherglen, Australia. In order to incorporate the effect of shading from adjacent tanks, trials were also conducted at Wagga Wagga, Australia, on a group of tanks where mutual shading was present. Each tank was fitted with sensors to study the effect of morning, afternoon and mid-day shading. A mathematical model was developed to predict the amount of solar heat load received by the tank. The model considered the effect of seasonal variations in radiation intensity, day length and sun angle. The model incorporated the size, spacing and orientation of the tanks as well as solar considerations such as time of year and latitude. This paper also presented background information on the solar radiation received by the earth. Solar radiation comprises direct radiation and diffuse radiation. Direct radiation refers to direct sunlight, travelling in parallel rays from the sun, while diffuse radiation refers to radiation which has been scattered by the atmosphere. In most cases, direct radiation is dominant, but both radiations are considered when calculating solar energy gains. The solar heating of the 25 kL tank of wine was calculated by isolating the solar heating from other heat flows. Fermentation was complete and no refrigeration was applied to the tank during the 5 days of the trial. Only

  1. High Level Waste Tank Closure Modeling with Geographic Information Systems (GIS)

    Energy Technology Data Exchange (ETDEWEB)

    BOLLINGER, JAMES

    2004-07-29

    Waste removal from 49 underground storage tanks located in two tank farms involves three steps: bulk waste removal, water washing to remove residual waste, and in some cases chemical cleaning to remove additional residual waste. Not all waste can be completely removed by these processes-resulting in some residual waste loading following cleaning. Completely removing this residual waste would be prohibitively expensive; therefore, it will be stabilized by filling the tanks with grout. Acceptable residual waste loading inventories were determined using one-dimensional groundwater transport modeling to predict future human exposure based on several scenarios. These modeling results have been incorporated into a geographic information systems (GIS) application for rapid evaluation of various tank closure options.

  2. Mercury Dispersion Modeling And Purge Ventilation Stack Height Determination For Tank 40H

    Energy Technology Data Exchange (ETDEWEB)

    Rivera-Giboyeaux, A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-05-19

    The SRNL Atmospheric Technologies Group performed an analysis for mercury emissions from H-Tank Farm - Tank 40 ventilation system exhaust in order to assess whether the Short Term Exposure Limit (STEL), or Threshold Limit Value (TLV) levels for mercury will be exceeded during bulk sludge slurry mixing and sludge removal operations. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the main dispersion modelling tool for this analysis. The results indicated that a 45-foot stack is sufficient to raise the plume centerline from the Tank 40 release to prevent mercury exposure problems for any of the stack discharge scenarios provided. However, a 42-foot stack at Tank 40 is sufficient to prevent mercury exposure concerns in all emission scenarios except the 50 mg/m3 release. At a 42-foot stack height, values exceeding the exposure standards are only measured on receptors located above 34 feet.

  3. Model of the Radio Frequency (RF) Excitation Response from Monopole and Dipole Antennas in a Large Scale Tank

    Science.gov (United States)

    Wilson, Jeffrey D.; Zimmerli, Gregory A.

    2012-01-01

    Good antenna-mode coupling is needed for determining the amount of propellant in a tank through the method of radio frequency mass gauging (RFMG). The antenna configuration and position in a tank are important factors in coupling the antenna to the natural electromagnetic modes. In this study, different monopole and dipole antenna mounting configurations and positions were modeled and responses simulated in a full-scale tank model with the transient solver of CST Microwave Studio (CST Computer Simulation Technology of America, Inc.). The study was undertaken to qualitatively understand the effect of antenna design and placement within a tank on the resulting radio frequency (RF) tank spectrum.

  4. DEVELOPING A MATHEMATICAL MODEL FOR THE PROCESS OF DEVELOPING A MATHEMATICAL MODEL FOR THE PROCESS OF SEDIMENTARY TANKS

    Directory of Open Access Journals (Sweden)

    Valeria Victoria IOVANOV

    2013-05-01

    Full Text Available The model is reformulated by means of stochastic differential equations, and the parametersare estimated by a maximum likelihood method.VESILIND (1968; 1979 proposed a sludge settling velocity model of exponential form. During recent years,several refinements to the original model have been proposed, see e.g. GRIJSPEERDT et al. (1995; DUPONTand DAHL (1995 EKAMA et al. (1997. In the proposed models several layers in the settling tank areincorporated to permit the calculation of SS profiles over the tank depth and predict the SS concentrations in thereturn sludge and in the effluent from the clarifier.Here, the original VESILIND model combined with a simple suction depth model is used to enable predictionof the SS concentration in the effluent from the tank. In order to make the model applicable for real time controlpurposes, only two layers of variable height in the tank are considered

  5. DOUBLE SHELL TANK (DST) HYDROXIDE DEPLETION MODEL FOR CARBON DIOXIDE ABSORPTION

    Energy Technology Data Exchange (ETDEWEB)

    OGDEN DM; KIRCH NW

    2007-10-31

    This document generates a supernatant hydroxide ion depletion model based on mechanistic principles. The carbon dioxide absorption mechanistic model is developed in this report. The report also benchmarks the model against historical tank supernatant hydroxide data and vapor space carbon dioxide data. A comparison of the newly generated mechanistic model with previously applied empirical hydroxide depletion equations is also performed.

  6. Studies on scaled models for gas entrainment in the surge tank of LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Ramdasu, D.; Shivakumar, N.S.; Padmakumar, G.; Anand Babu, C.; Vaidyanathan, G. [Fast Reactor Technology Group, Indira Gandhi Centre for Atomic Research, Kalpakkam (India); Rammohan, S.; Sreekala, S.K.; Manikandan, S.; Saseendran, S. [Fluid Control Research Institute, Palghat (India)

    2007-07-01

    This paper presents the studies carried out in the different scale models of Surge tank used in the secondary circuit of Liquid metal fast breeder reactor (LMFBR). Surge tank acquires importance because of its ability to take care of pressure surges in case of a sodium water reaction in Steam Generators (SG). The blanket of argon cover gas above the sodium free surface in the surge tank acts as a cushion for the surges. At the same time, argon gas is a source of entrainment into the sodium which is undesirable from the consideration of effective heat transfer in Inter mediate Heat Exchanger and SG, cavitation in pumps and operational problems of continuous feed and bleed of cover gas, thus leading to unfavourable reactor operating conditions. To investigate the phenomenon of gas entrainment in surge tank, hydraulic experiments were conducted in water using 1/38, 1/32, 1/22 and 1/12 scale models with Froude similarity. The minimum height of liquid column required to avoid gas entrainment was determined using different types of internal devices. Experiments were carried out in the 5/8 scale model to confirm the results of the smaller scale models. It was found that free surface height to avoid gas entrainment varies for different scale models. The combination of Pepper pot with ring plate was found to be the most effective in avoiding gas entrainment at H/D equals 1.28 where H is the height of liquid column in the tank from tank bottom and D is the inner diameter of surge tank.

  7. Dynamic modeling of sludge compaction and consolidation processes in wastewater secondary settling tanks

    NARCIS (Netherlands)

    Abusam, A.; Keesman, K.J.

    2009-01-01

    The double exponential settling model is the widely accepted model for wastewater secondary settling tanks. However, this model does not estimate accurately solids concentrations in the settler underflow stream, mainly because sludge compression and consolidation processes are not considered. In act

  8. Application of Tank Model for Predicting Water Balance and Flow Discharge Components of Cisadane Upper Catchment

    Directory of Open Access Journals (Sweden)

    Nana Mulyana Arifjaya

    2012-01-01

    Full Text Available The concept of hydrological tank model was well described into four compartments (tanks. The first tank (tank A comprised of one vertical (qA0 and two lateral (qA1 and qA2 water flow components and tank B comprised of one vertical (qB0 and one lateral (qB1 water flow components. Tank C comprised of one vertical (qC0 and one lateral (qC1 water flow components, whereas tank D comprised of one lateral water flow component (qD1.  These vertical water flows would also contribute to the depletion of water flow in the related tanks but would replenish tanks in the deeper layers. It was assumed that at all lateral water flow components would finally accumulate in one stream, summing-up of the lateral water flow, much or less, should be equal to the water discharge (Qo at specified time concerns. Tank A received precipitation (R and evapo-transpiration (ET which was its gradientof (R-ET over time would become the driving force for the changes of water stored in the soil profiles and thosewater flows leaving the soil layer.  Thus tank model could describe th vertical and horizontal water flow withinthe watershed. The research site was Cisadane Upper Catchment, located at Pasir Buncir Village of CaringinSub-District within the Regency of Bogor in West Java Province.  The elevations ranged 512 –2,235 m above sealevel, with a total drainage area of 1,811.5 ha and total length of main stream of 14,340.7 m.  The land cover wasdominated by  forest  with a total of 1,044.6 ha (57.67%,  upland agriculture with a total of 477.96 ha (26.38%,mixed garden with a total of 92.85 ha(5.13% and semitechnical irigated rice field with a total of 196.09 ha (10,8%.  The soil was classified as hydraquent (96.6% and distropept (3.4%.  Based on the calibration of tank model application in the study area, the resulting coefficient of determination (R2 was 0.72 with model efficiency (NSEof= 0.75, thus tank model could well illustrate the water flow distribution of

  9. Identification and Control of a Cylindrical Tank Based on System Identification Models

    Directory of Open Access Journals (Sweden)

    Mary Mol Paul

    2013-06-01

    Full Text Available Advancements in the process control industry has made difficulties in controlling processes which are highly complex in nature. System identification provides a better solution for this problem with the help of identification models. In this paper ARX,ARMAX,BJ and OE models were used for the identification of a cylindrical tank and Ziegler Nichols tuning method to develop the controller for controlling the level of the tank. The proposed method provides simple and accurate models and thereby improving the efficency of identification process. MATLAB and LABView softwares were used here for identification and controlling.

  10. Comparison of three computational models for predicting pressurization characteristics of cryogenic tank during discharge

    Science.gov (United States)

    Lei, Wang; Yanzhong, Li; Kang, Zhu; Yonghua, Jin

    2015-01-01

    In order to select an effective approach to predict the pressurization characteristics of cryogenic tank during rocket launching, three computational models, defined as 0-D, 1-D and CFD models, are used to obtain the pressure evolution and thermal performance of a cryogenic tank during pressurized discharge period. Several pressurization cases are computed by all of the three models to evaluate their predictive abilities and effects, respectively. The comparative study shows that for the case with a diffuser-type injector at the tank inlet, the consistent results by the three models are obtained in the most of period, except that 1-D model has a peak departure prediction of pressure value at the beginning of process. All of the three models can be used to predict the pressurization performance, and their predictive abilities could be validated with one another. The CFD model is the unique suitable model to display the pressurization performance including physical distribution in radial direction especially for the system with no-diffuser-type injector. Based on the analysis, the application selection of three models for different cases is accomplished. The 0-D model is the priority selection for a simple pressure prediction of tank ullage, even for the situation that severe temperature distribution exists in the ullage range. The 1-D model is the optimal selection as considering both the convenience and the time consumption for the constant-pressure cases. But it is not recommended in a constant-inlet flux cases for its distinct predicting deviation at the beginning of the process. When the detailed distributions within the tank are concerned, the CFD model is the unique selection. The results of this paper may be beneficial to the model selection and optimization analysis of a pressurization system.

  11. Experimental Determination and Thermodynamic Modeling of Electrical Conductivity of SRS Waste Tank Supernate

    Energy Technology Data Exchange (ETDEWEB)

    Pike, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Reboul, S. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-06-01

    SRS High Level Waste Tank Farm personnel rely on conductivity probes for detection of incipient overflow conditions in waste tanks. Minimal information is available concerning the sensitivity that must be achieved such that that liquid detection is assured. Overly sensitive electronics results in numerous nuisance alarms for these safety-related instruments. In order to determine the minimum sensitivity required of the probe, Tank Farm Engineering personnel need adequate conductivity data to improve the existing designs. Little or no measurements of liquid waste conductivity exist; however, the liquid phase of the waste consists of inorganic electrolytes for which the conductivity may be calculated. Savannah River Remediation (SRR) Tank Farm Facility Engineering requested SRNL to determine the conductivity of the supernate resident in SRS waste Tank 40 experimentally as well as computationally. In addition, SRNL was requested to develop a correlation, if possible, that would be generally applicable to liquid waste resident in SRS waste tanks. A waste sample from Tank 40 was analyzed for composition and electrical conductivity as shown in Table 4-6, Table 4-7, and Table 4-9. The conductivity for undiluted Tank 40 sample was 0.087 S/cm. The accuracy of OLI Analyzer™ was determined using available literature data. Overall, 95% of computed estimates of electrical conductivity are within ±15% of literature values for component concentrations from 0 to 15 M and temperatures from 0 to 125 °C. Though the computational results are generally in good agreement with the measured data, a small portion of literature data deviates as much as ±76%. A simplified model was created that can be used readily to estimate electrical conductivity of waste solution in computer spreadsheets. The variability of this simplified approach deviates up to 140% from measured values. Generally, this model can be applied to estimate the conductivity within a factor of two. The comparison of the

  12. Investigating and modeling of the effects of condensate storage tank fire in a refinery

    Directory of Open Access Journals (Sweden)

    Mohammad Kamaei

    2015-12-01

    Full Text Available Background & objective: Oil storage tanks are major industrial facilities which always pose risks of toxic substance release, fires and explosions. Fire has been recognized as the most common risk associated with such facilities, while explosion is the most important one in terms of ability to claim human lives and damage property. The current study aimed at investigating and modeling the effects of fires occurring in a gas condensate tank farm, according to which the level of possible emergencies were specified using the guidelines provided by the Center for Chemical Process Safety. Lastly, control measures were recommended. Methods: In the present study, the release and leakage of gas condensate from floating roof tanks were assessed using HAZOP method. Then, using PHAST software, the amount of radiation intensity received by the surrounding environment was determined, safe boundaries were computed, and according to the CCPS standard the emergency levels were determined. Results: modeling was performed based on the maximum capacity of tanks for both cold and hot seasons. The results revealed that safe distance for a maximum amount of irradiation density (4 KW/m2 related to a sudden release were 60 and 140 meters, respectively. Conclusion: according to the current condition of the plants and storage tanks, a plan was recommended for emergency management and practical suggestions were provided to improve the reliability and consistency.

  13. Implications of the modelling of stratified hot water storage tanks in the simulation of CHP plants

    Energy Technology Data Exchange (ETDEWEB)

    Campos Celador, A., E-mail: alvaro.campos@ehu.es [ENEDI Research Group-University of the Basque Country, Departamento de Maquinas y Motores Termicos, E.T.S.I. de Bilbao Alameda de Urquijo, s/n 48013 Bilbao, Bizkaia (Spain); Odriozola, M.; Sala, J.M. [ENEDI Research Group-University of the Basque Country, Departamento de Maquinas y Motores Termicos, E.T.S.I. de Bilbao Alameda de Urquijo, s/n 48013 Bilbao, Bizkaia (Spain)

    2011-08-15

    Highlights: {yields} Three different modelling approaches for simulation of hot water tanks are presented. {yields} The three models are simulated within a residential cogeneration plant. {yields} Small differences in the results are found by an energy and exergy analysis. {yields} Big differences between the results are found by an advanced exergy analysis. {yields} Results on the feasibility study are explained by the advanced exergy analysis. - Abstract: This paper considers the effect that different hot water storage tank modelling approaches have on the global simulation of residential CHP plants as well as their impact on their economic feasibility. While a simplified assessment of the heat storage is usually considered in the feasibility studies of CHP plants in buildings, this paper deals with three different levels of modelling of the hot water tank: actual stratified model, ideal stratified model and fully mixed model. These three approaches are presented and comparatively evaluated under the same case of study, a cogeneration plant with thermal storage meeting the loads of an urbanisation located in the Bilbao metropolitan area (Spain). The case of study is simulated by TRNSYS for each one of the three modelling cases and the so obtained annual results are analysed from both a First and Second-Law-based viewpoint. While the global energy and exergy efficiencies of the plant for the three modelling cases agree quite well, important differences are found between the economic results of the feasibility study. These results can be predicted by means of an advanced exergy analysis of the storage tank considering the endogenous and exogenous exergy destruction terms caused by the hot water storage tank.

  14. Modeling of a lot scale rainwater tank system in XP-SWMM: a case study in Western Sydney, Australia.

    Science.gov (United States)

    van der Sterren, Marlène; Rahman, Ataur; Ryan, Garry

    2014-08-01

    Lot scale rainwater tank system modeling is often used in sustainable urban storm water management, particularly to estimate the reduction in the storm water run-off and pollutant wash-off at the lot scale. These rainwater tank models often cannot be adequately calibrated and validated due to limited availability of observed rainwater tank quantity and quality data. This paper presents calibration and validation of a lot scale rainwater tank system model using XP-SWMM utilizing data collected from two rainwater tank systems located in Western Sydney, Australia. The modeling considers run-off peak and volume in and out of the rainwater tank system and also a number of water quality parameters (Total Phosphorus (TP), Total Nitrogen (TN) and Total Solids (TS)). It has been found that XP-SWMM can be used successfully to develop a lot scale rainwater system model within an acceptable error margin. It has been shown that TP and TS can be predicted more accurately than TN using the developed model. In addition, it was found that a significant reduction in storm water run-off discharge can be achieved as a result of the rainwater tank up to about one year average recurrence interval rainfall event. The model parameter set assembled in this study can be used for developing lot scale rainwater tank system models at other locations in the Western Sydney region and in other parts of Australia with necessary adjustments for the local site characteristics.

  15. Hanford Tank 241-C-106: Residual Waste Contaminant Release Model and Supporting Data

    Energy Technology Data Exchange (ETDEWEB)

    Deutsch, William J.; Krupka, Kenneth M.; Lindberg, Michael J.; Cantrell, Kirk J.; Brown, Christopher F.; Schaef, Herbert T.

    2007-05-23

    This report was revised in May 2007 to correct values in Section 3.4.1.7, second paragraph, last sentence; 90Sr values in Tables 3.22 and 3.32; and 99Tc values Table 4.3 and in Chapter 5. In addition, the tables in Appendix F were updated to reflect corrections to the 90Sr values. The rest of the text remains unchanged from the original report issued in May 2005. CH2M HILL is producing risk/performance assessments to support the closure of single-shell tanks at the DOE's Hanford Site. As part of this effort, staff at PNNL were asked to develop release models for contam¬inants of concern that are present in residual sludge remaining in tank 241-C-106 (C-106) after final retrieval of waste from the tank. This report provides the information developed by PNNL.

  16. Development of a new model for batch sedimentation and application to secondary settling tanks design.

    Science.gov (United States)

    Karamisheva, Ralica D; Islam, M A

    2005-01-01

    Assuming that settling takes place in two zones (a constant rate zone and a variable rate zone), a model using four parameters accounting for the nature of the water-suspension system has been proposed for describing batch sedimentation processes. The sludge volume index (SVI) has been expressed in terms of these parameters. Some disadvantages of the SVI application as a design parameter have been pointed out, and it has been shown that a relationship between zone settling velocity and sludge concentration is more consistent for describing the settling behavior and for design of settling tanks. The permissible overflow rate has been related to the technological parameters of secondary settling tank by simple working equations. The graphical representations of these equations could be used to optimize the design and operation of secondary settling tanks.

  17. Dynamic modeling of sludge compaction and consolidation processes in wastewater secondary settling tanks.

    Science.gov (United States)

    Abusam, A; Keesman, K J

    2009-01-01

    The double exponential settling model is the widely accepted model for wastewater secondary settling tanks. However, this model does not estimate accurately solids concentrations in the settler underflow stream, mainly because sludge compression and consolidation processes are not considered. In activated sludge systems, accurate estimation of the solids in the underflow stream will facilitate the calibration process and can lead to correct estimates of particularly kinetic parameters related to biomass growth. Using principles of compaction and consolidation, as in soil mechanics, a dynamic model of the sludge consolidation processes taking place in the secondary settling tanks is developed and incorporated to the commonly used double exponential settling model. The modified double exponential model is calibrated and validated using data obtained from a full-scale wastewater treatment plant. Good agreement between predicted and measured data confirmed the validity of the modified model.

  18. Experimental Validation of a Domestic Stratified Hot Water Tank Model in Modelica for Annual Performance Assessment

    DEFF Research Database (Denmark)

    Carmo, Carolina; Dumont, Olivier; Nielsen, Mads Pagh

    2015-01-01

    coupled with energy system solutions is limited. In this poster, a discretized model of a stratified tank developed in Modelica is presented. The physical phenoma to be considered are the thermal transfers by conduction and convection – stratification, heat loss to ambient, charging and discharging...

  19. Improving farm management by modeling the contamination of farm tank milk with butyric acid bacteria

    NARCIS (Netherlands)

    Vissers, M.M.M.; Driehuis, F.; Giffel, te M.C.; Jong, de P.; Lankveld, J.M.G.

    2006-01-01

    Control of contamination of farm tank milk (FTM) with the spore-forming butyric acid bacteria (BAB) is important to prevent the late-blowing defect in semi-hard cheeses. The risk of late blowing can be decreased via control of the contamination level of FTM with BAB. A modeling approach was applied

  20. Improving farm management by modeling the contamination of farm tank milk with butyric acid bacteria

    NARCIS (Netherlands)

    Vissers, M.M.M.; Driehuis, F.; Giffel, te M.C.; Jong, de P.; Lankveld, J.M.G.

    2006-01-01

    Control of contamination of farm tank milk (FTM) with the spore-forming butyric acid bacteria (BAB) is important to prevent the late-blowing defect in semi-hard cheeses. The risk of late blowing can be decreased via control of the contamination level of FTM with BAB. A modeling approach was applied

  1. Stochastic simulation modeling to determine time to detect Bovine Viral Diarrhea antibodies in bulk tank milk

    DEFF Research Database (Denmark)

    Foddai, Alessandro; Enøe, Claes; Krogh, Kaspar

    2014-01-01

    A stochastic simulation model was developed to estimate the time from introduction ofBovine Viral Diarrhea Virus (BVDV) in a herd to detection of antibodies in bulk tank milk(BTM) samples using three ELISAs. We assumed that antibodies could be detected, after afixed threshold prevalence...

  2. A consistent modelling methodology for secondary settling tanks in wastewater treatment.

    Science.gov (United States)

    Bürger, Raimund; Diehl, Stefan; Nopens, Ingmar

    2011-03-01

    The aim of this contribution is partly to build consensus on a consistent modelling methodology (CMM) of complex real processes in wastewater treatment by combining classical concepts with results from applied mathematics, and partly to apply it to the clarification-thickening process in the secondary settling tank. In the CMM, the real process should be approximated by a mathematical model (process model; ordinary or partial differential equation (ODE or PDE)), which in turn is approximated by a simulation model (numerical method) implemented on a computer. These steps have often not been carried out in a correct way. The secondary settling tank was chosen as a case since this is one of the most complex processes in a wastewater treatment plant and simulation models developed decades ago have no guarantee of satisfying fundamental mathematical and physical properties. Nevertheless, such methods are still used in commercial tools to date. This particularly becomes of interest as the state-of-the-art practice is moving towards plant-wide modelling. Then all submodels interact and errors propagate through the model and severely hamper any calibration effort and, hence, the predictive purpose of the model. The CMM is described by applying it first to a simple conversion process in the biological reactor yielding an ODE solver, and then to the solid-liquid separation in the secondary settling tank, yielding a PDE solver. Time has come to incorporate established mathematical techniques into environmental engineering, and wastewater treatment modelling in particular, and to use proven reliable and consistent simulation models.

  3. CFD Modeling of Helium Pressurant Effects on Cryogenic Tank Pressure Rise Rates in Normal Gravity

    Science.gov (United States)

    Grayson, Gary; Lopez, Alfredo; Chandler, Frank; Hastings, Leon; Hedayat, Ali; Brethour, James

    2007-01-01

    A recently developed computational fluid dynamics modeling capability for cryogenic tanks is used to simulate both self-pressurization from external heating and also depressurization from thermodynamic vent operation. Axisymmetric models using a modified version of the commercially available FLOW-3D software are used to simulate actual physical tests. The models assume an incompressible liquid phase with density that is a function of temperature only. A fully compressible formulation is used for the ullage gas mixture that contains both condensable vapor and a noncondensable gas component. The tests, conducted at the NASA Marshall Space Flight Center, include both liquid hydrogen and nitrogen in tanks with ullage gas mixtures of each liquid's vapor and helium. Pressure and temperature predictions from the model are compared to sensor measurements from the tests and a good agreement is achieved. This further establishes the accuracy of the developed FLOW-3D based modeling approach for cryogenic systems.

  4. Development of a flocculation sub-model for a 3-D CFD model based on rectangular settling tanks.

    Science.gov (United States)

    Gong, M; Xanthos, S; Ramalingam, K; Fillos, J; Beckmann, K; Deur, A; McCorquodale, J A

    2011-01-01

    To assess performance and evaluate alternatives to improve the efficiency of rectangular Gould II type final settling tanks (FSTs), New York City Department of Environmental Protection and City College of NY developed a 3D computer model depicting the actual structural configuration of the tanks and the current and proposed hydraulic and solids loading rates. Fluent 6.3.26™ was the base platform for the computational fluid dynamics (CFD) model, for which sub-models of the SS settling characteristics, turbulence, flocculation and rheology were incorporated. This was supplemented by field and bench scale experiments to quantify the coefficients integral to the sub-models. The 3D model developed can be used to consider different baffle arrangements, sludge withdrawal mechanisms and loading alternatives to the FSTs. Flocculation in the front half of the rectangular tank especially in the region before and after the inlet baffle is one of the vital parameters that influences the capture efficiency of SS. Flocculation could be further improved by capturing medium and small size particles by creating an additional zone with an in-tank baffle. This was one of the methods that was adopted in optimizing the performance of the tank where the CCNY 3D CFD model was used to locate the in-tank baffle position. This paper describes the development of the flocculation sub-model and the relationship of the flocculation coefficients in the known Parker equation to the initial mixed liquor suspended solids (MLSS) concentration X0. A new modified equation is proposed removing the dependency of the breakup coefficient to the initial value of X0 based on preliminary data using normal and low concentration mixed liquor suspended solids values in flocculation experiments performed.

  5. Three-Dimensional Scale-Model Tank Experiment of the Hudson Canyon Region

    Science.gov (United States)

    2014-09-30

    Three-Dimensional Scale-Model Tank Experiment of the Hudson Canyon Region Jason D. Sagers Applied Research Laboratories at The University of...planning for future experiments in ocean environments with slopes and canyons . APPROACH The development of fully 3D numerical acoustic propagation models...Experiment of the Hudson Canyon Region 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER

  6. Modelling of a solid oxide fuel cell CHP system coupled with a hot water storage tank for a single household

    DEFF Research Database (Denmark)

    Liso, Vincenzo; Zhao, Yingru; Yang, Wenyuan

    2015-01-01

    In this paper a solid oxide fuel cell (SOFC) system for cogeneration of heat and power integrated with a stratified heat storage tank is studied. The use of a storage tank with thermal stratification allows one to increase the annual operating hours of CHP: heat can be produced when the request...... produced by gasification and natural gas. The tank model considers the temperature gradients over the tank height. The results of the numerical simulation are used to size the SOFC system and storage heat tank to provide energy for a small household using two different fuels. In particular it was shown...... is low (for instance during the night), taking advantage of thermal stratification to increases the heat recovery performance. A model of the SOFC system is presented to estimate the energy required to meet the average electric energy demand of the residence. Two fuels are considered, namely syngas...

  7. Physics-Based Fragment Acceleration Modeling for Pressurized Tank Burst Risk Assessments

    Science.gov (United States)

    Manning, Ted A.; Lawrence, Scott L.

    2014-01-01

    As part of comprehensive efforts to develop physics-based risk assessment techniques for space systems at NASA, coupled computational fluid and rigid body dynamic simulations were carried out to investigate the flow mechanisms that accelerate tank fragments in bursting pressurized vessels. Simulations of several configurations were compared to analyses based on the industry-standard Baker explosion model, and were used to formulate an improved version of the model. The standard model, which neglects an external fluid, was found to agree best with simulation results only in configurations where the internal-to-external pressure ratio is very high and fragment curvature is small. The improved model introduces terms that accommodate an external fluid and better account for variations based on circumferential fragment count. Physics-based analysis was critical in increasing the model's range of applicability. The improved tank burst model can be used to produce more accurate risk assessments of space vehicle failure modes that involve high-speed debris, such as exploding propellant tanks and bursting rocket engines.

  8. Comparison between models for the simulation of hot water storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    Oliveski, R.D.C. [Universidade do Vale do Rio dos Sinos, Sao Leopoldo, RS (Brazil). Centro de Ciencas Exatas e Tecnologicas, Engenharia Mecanica; Krenzinger, A. [Universiade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil). Departamento de Engenharia de Materiais; Vielmo, H.A. [Universiade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil). Departamento de Engenharia Mecanica

    2003-08-01

    Numerical and experimental analyses of velocity and temperature fields inside a tank submitted to internal natural and mixed convection are presented in this paper. The numerical analyses were performed with two approaches: one using a two-dimensional model in cylindrical coordinates through the finite volume method and another using a one-dimensional model. A turbulence model for low Reynolds numbers was added to the two--dimensional model in mixed convection regime. The two-dimensional model was experimentally validated and then adopted as reference. Its results were compared to those obtained with one-dimensional models (combined with certain computational artifices described in this work) with a good agreement. (author)

  9. Detailed modeling of sloshing in satellites tank at low Bond numbers

    Science.gov (United States)

    Lepilliez, Mathieu; Tanguy, Sebastien; Interface Team

    2015-11-01

    Consumption of ergols is a critical issue regarding the whole lifetime of a satellite. During maneuvers in mission phases, the Helium bubble used to pressurize the tank can move freely inside, thus generating movement of the center of mass, and sloshing which can disrupt the control of the satellite. In this study we present numerical results obtained from CFD computation, using an Immersed Interface Method to model the tank with a level-set approach for both liquid-gas interface and solid-fluid interface. A parametric study is proposed to observe the influence of the Bond number on resulting forces and torques generated on the tank. One can observe different steps during the maneuvers under microgravity: the first part is dominated by accelerations and volume forces, which flatten the bubble on the hydrophilic tank wall. When the forcing stops, the bubble bounces back, generating sloshing by moving under the influence of inertia and capillary effects. Finally viscous effects damp the sloshing by dissipating the kinetic energy of the bubble. Those results are compared to actual in-flight data for different typical maneuvers on forces and torques, allowing us to characterize the period and damping of the sloshing. CNES/ Airbus Defence & Space funding.

  10. The Sort on Radioactive Waste Type model: A method to sort single-shell tanks into characteristic groups. Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    Hill, J.G.; Anderson, G.S. [Pacific Northwest Lab., Richland, WA (United States); Simpson, B.C. [Westinghouse Hanford Co., Richland, WA (United States)

    1995-03-01

    The SORWT model presents a methodology to group SSTs that is both simple to understand and logical in its assumptions and construction. The SORWT model has predicted the existence of 24 groups of SSTs ranging from 22 tanks per group to two tanks per group. These 24 groups encompass 133 tanks and 93% of the total waste contained in SSTs. The first 14 groups (i.e., those that contain four tanks per group or more) represent 109 tanks and 83% of the total waste volume. This demonstrates the potential for using the SORWT model to efficiently allocate resources and to maximize characterization information gained by a minimum number of sampling events. The verification study has shown that the SST groups predicted by the SORWT model are statistically significant and reduce the variability in the concentrations for all analytes examined. The SORWT model organizes a vast amount of information and presents clear options on which SSTs are more desirable to sample. The model is also simple and flexible in its ability to incorporate new parameters such as new SST analytical data, shifting programmatic needs, and/or risk assessment-oriented criteria. This report presents the nominal composition, inventory, and uncertainty for five of the 24 SORWT groups, representing 28 tanks, 10% of the total waste volume, and 29% of the total sludge volume in SSTs. Consequently, this document provides a logical beginning framework for tank waste characterization until further information becomes available or different programmatic needs are identified.

  11. Experimental Characterisation and Modelling of Homogeneous Solid Suspension in an Industrial Stirred Tank

    Directory of Open Access Journals (Sweden)

    Sébastien Calvo

    2013-01-01

    Full Text Available In this work, we study the conditions needed to reach homogeneous distribution of aluminium salts particles in water inside a torispherical bottom shaped stirred tank of 70 L equipped with a Pfaudler RCI type impeller and three equispaced vertical baffles. The aim of the present study is to develop a CFD model describing the quality of particle distribution in industrial scale tanks. This model, validated with experimental data, is used afterwards to develop scale-up and scale-down correlations to predict the minimum impeller speed needed to reach homogeneous solid distribution Nhs. The commercial CFD software Fluent 14 is used to model the fluid flow and the solid particle distribution in the tank. Sliding Mesh approach is used to take the impeller motion into account. Assuming that the discrete solid phase has no influence on the continuous liquid phase behaviour, the fluid flow dynamics is simulated independently using the well-known k-∊ turbulence model. The liquid-solid mixture behaviour is then described by implementing the Eulerian Mixture model. Computed liquid velocity fields are validated by comparison with PIV measurements. Computed Nhs were found to be in good agreement with experimental measurements. Results from different scales allowed correlating Nhs values to the volumetric power consumption.

  12. Modeling and Analysis of Chill and Fill Processes for the EDU Tank

    Science.gov (United States)

    Hedayat, A.; Cartagena, W.; Majumdar, A. K.; Leclair, A. C.

    2015-01-01

    NASA's future missions may require long-term storage and transfer of cryogenic propellants. The Engineering Development Unit (EDU), a NASA in-house effort supported by both Marshall Space Flight Center (MSFC) and Glenn Research Center (GRC), is a Cryogenic Fluid Management (CFM) test article that primarily serves as a manufacturing pathfinder and a risk reduction task for a future CFM payload. The EDU test article, comprises a flight like tank, internal components, insulation, and attachment struts. The EDU is designed to perform integrated passive thermal control performance testing with liquid hydrogen in a space-like vacuum environment. A series of tests, with liquid hydrogen as a testing fluid, was conducted at Test Stand 300 at MSFC during summer of 2014. The objective of this effort was to develop a thermal/fluid model for evaluating the thermodynamic behavior of the EDU tank during the chill and fill processes. Generalized Fluid System Simulation Program (GFSSP), an MSFC in-house general-purpose computer program for flow network analysis, was utilized to model and simulate the chill and fill portion of the testing. The model contained the liquid hydrogen supply source, feed system, EDU tank, and vent system. The modeling description and comparison of model predictions with the test data will be presented in the final paper.

  13. Numerical Modelling and Measurement in a Test Secondary Settling Tank

    DEFF Research Database (Denmark)

    Dahl, C.; Larsen, Torben; Petersen, O.

    1994-01-01

    A numerical model and measurements of flow and settling in activated sludge suspension is presented. The numerical model is an attempt to describe the complex and interrelated hydraulic and sedimentation phenomena by describing the turbulent flow field and the transport/dispersion of suspended sl...

  14. A History of Collapse Factor Modeling and Empirical Data for Cryogenic Propellant Tanks

    Science.gov (United States)

    deQuay, Laurence; Hodge, B. Keith

    2010-01-01

    One of the major technical problems associated with cryogenic liquid propellant systems used to supply rocket engines and their subassemblies and components is the phenomenon of propellant tank pressurant and ullage gas collapse. This collapse is mainly caused by heat transfer from ullage gas to tank walls and interfacing propellant, which are both at temperatures well below those of this gas. Mass transfer between ullage gas and cryogenic propellant can also occur and have minor to significant secondary effects that can increase or decrease ullage gas collapse. Pressurant gas is supplied into cryogenic propellant tanks in order to initially pressurize these tanks and then maintain required pressures as propellant is expelled from these tanks. The net effect of pressurant and ullage gas collapse is increased total mass and mass flow rate requirements of pressurant gases. For flight vehicles this leads to significant and undesirable weight penalties. For rocket engine component and subassembly ground test facilities this results in significantly increased facility hardware, construction, and operational costs. "Collapse Factor" is a parameter used to quantify the pressurant and ullage gas collapse. Accurate prediction of collapse factors, through analytical methods and modeling tools, and collection and evaluation of collapse factor data has evolved over the years since the start of space exploration programs in the 1950 s. Through the years, numerous documents have been published to preserve results of studies associated with the collapse factor phenomenon. This paper presents a summary and selected details of prior literature that document the aforementioned studies. Additionally other literature that present studies and results of heat and mass transfer processes, related to or providing important insights or analytical methods for the studies of collapse factor, are presented.

  15. Modeling Xenon Tank Pressurization using One-Dimensional Thermodynamic and Heat Transfer Equations

    Science.gov (United States)

    Gilligan, Ryan P.; Tomsik, Thomas M.

    2017-01-01

    As a first step in understanding what ground support equipment (GSE) is required to provide external cooling during the loading of 5,000 kg of xenon into 4 aluminum lined composite overwrapped pressure vessels (COPVs), a modeling analysis was performed using Microsoft Excel. The goals of the analysis were to predict xenon temperature and pressure throughout loading at the launch facility, estimate the time required to load one tank, and to get an early estimate of what provisions for cooling xenon might be needed while the tanks are being filled. The model uses the governing thermodynamic and heat transfer equations to achieve these goals. Results indicate that a single tank can be loaded in about 15 hours with reasonable external coolant requirements. The model developed in this study was successfully validated against flight and test data. The first data set is from the Dawn mission which also utilizes solar electric propulsion with xenon propellant, and the second is test data from the rapid loading of a hydrogen cylindrical COPV. The main benefit of this type of model is that the governing physical equations using bulk fluid solid temperatures can provide a quick and accurate estimate of the state of the propellant throughout loading which is much cheaper in terms of computational time and licensing costs than a Computation Fluid Dynamics (CFD) analysis while capturing the majority of the thermodynamics and heat transfer.

  16. SINGLE-SHELL TANK INTEGRITY PROJECT ANALYSIS OF RECORD-PRELIMINARY MODELING PLAN FOR THERMAL AND OPERATING LOADS

    Energy Technology Data Exchange (ETDEWEB)

    RAST RS; RINKER MW; BAPANAALLI SK; DEIBLER JE; GUZMAN-LEONG CE; JOHNSON KI; KARRI NK; PILLI SP; SANBORN SE

    2010-10-22

    This document is a Phase I deliverable for the Single-Shell Tank Analysis of Record effort. This document is not the Analysis of Record. The intent of this document is to guide the Phase II detailed modeling effort. Preliminary finite element models for each of the tank types were developed and different case studies were performed on one or more of these tank types. Case studies evaluated include thermal loading, waste level variation, the sensitivity of boundary effects (soil radial extent), excavation slope or run to rise ratio, soil stratigraphic (property and layer thickness) variation at different farm locations, and concrete material property variation and their degradation under thermal loads. The preliminary analysis document reviews and preliminary modeling analysis results are reported herein. In addition, this report provides recommendations for the next phase of the SST AOR project, SST detailed modeling. Efforts and results discussed in this report do not include seismic modeling as seismic modeling is covered by a separate report. The combined results of both static and seismic models are required to complete this effort. The SST AOR project supports the US Department of Energy's (DOE) Office of River Protection (ORP) mission for obtaining a better understanding of the structural integrity of Hanford's SSTs. The 149 SSTs, with six different geometries, have experienced a range of operating histories which would require a large number of unique analyses to fully characterize their individual structural integrity. Preliminary modeling evaluations were conducted to determine the number of analyses required for adequate bounding of each of the SST tank types in the Detailed Modeling Phase of the SST AOR Project. The preliminary modeling was conducted in conjunction with the Evaluation Criteria report, Johnson et al. (2010). Reviews of existing documents were conducted at the initial stage of preliminary modeling. These reviews guided the topics

  17. Modelling of stratification in cryogenic launch vehicle tanks in a fast engineering tool

    Science.gov (United States)

    van Foreest, Arnold

    Modelling of stratification in cryogenic launch vehicle tanks in a fast engineering tool Thermal stratification in cryogenic launch vehicle tanks can lead to several problems, such as sudden pressure drops in the tank due to sloshing of the stratified liquid or cavitation in rocket engine turbopumps. To obtain an optimal stage design, the stratification process muss be taken into account. Currently, stratification is often modelled by 3D CFD solvers, which is an extremely time consuming process. Analytical models do exists but are inaccurate. This paper will show how the currently existing analytical models are improved, by using experimental data and results obtained from numerical calculations using the 3D CFD tool FLOW 3D. The goal is to be able to model a stratification process of a few hundred seconds in just a few seconds of CPU time, so about a factor 100 faster than the physical process takes. A simulation using a 3D flow solver can take multiple days. Setting up the model for a 3D flow solver can even take longer. Therefore it would be a big advantage to have fast engineering tools describing the process so that stratification can be taken into account in the preliminary design phase. The stratification process has been investigated experimentally at ZARM (Centre of Applied Spaceflight and Microgravity), using a closed tank filled with liquid nitrogen. Due to unavoidable heat leaks from the surrounding, the liquid will start to heat up and thermal layers will form. The experiments are simulated using the commercial 3D flow solver "FLOW 3D". Once satisfying numerical results have been obtained, the stratification process can be investigated in more detail. The dimensioning parameters can be determined and their influence can be quantified. From these analyses it has been found that for example heat conduction through the tank wall in tangential direction has a big impact on the formation of thermal layers. The currently available analytical models for

  18. Tanks and Tank Troops

    Science.gov (United States)

    1982-03-01

    operational in the Bundeswehr. These include the well-known U.S. M113 APC, the HS-30 APC, developed by the Swiss company Hispano- Suiza , as well as the...powered by the Leyland L-60 engine, and the French AMX-30, powered by the Hispano- Suiza HS-110 engine. The new Japanese STB-6 tank (ඒ") is...of all foreign series-produced tank engines. A complete tank engine replacement can be performed in four hours. The Hispano- Suiza HS-110 engine

  19. Tank Tests of Model 36 Flying Boat Hull

    Science.gov (United States)

    Allison, John

    1938-01-01

    N.A.C.A. Model 36, a hull form with parallel middle body for half the length of the forebody and designed particularly for use with stub wings, was tested according to the general fixed-trim method over the range of practical loads, trims, and speeds. It was also tested free to trim with the center of gravity at two different positions. The results are given in the form of nondimensional coefficients. The resistance at the hump was exceptionally low but, at high planing speeds, afterbody interference made the performance only mediocre.

  20. Numerical Modeling of an Integrated Vehicle Fluids System Loop for Pressurizing a Cryogenic Tank

    Science.gov (United States)

    LeClair, A. C.; Hedayat, A.; Majumdar, A. K.

    2017-01-01

    This paper presents a numerical model of the pressurization loop of the Integrated Vehicle Fluids (IVF) system using the Generalized Fluid System Simulation Program (GFSSP). The IVF propulsion system, being developed by United Launch Alliance to reduce system weight and enhance reliability, uses boiloff propellants to drive thrusters for the reaction control system as well as to run internal combustion engines to develop power and drive compressors to pressurize propellant tanks. NASA Marshall Space Flight Center (MSFC) conducted tests to verify the functioning of the IVF system using a flight-like tank. GFSSP, a finite volume based flow network analysis software developed at MSFC, has been used to support the test program. This paper presents the simulation of three different test series, comparison of numerical prediction and test data and a novel method of presenting data in a dimensionless form. The paper also presents a methodology of implementing a compressor map in a system level code.

  1. Mathematical Modeling of the Thermal Shell State of the Cylindrical Cryogenic Tank During Filling and Emptying

    Directory of Open Access Journals (Sweden)

    V. S. Zarubin

    2015-01-01

    Full Text Available Liquid hydrogen and oxygen are used as the oxidizer and fuel for liquid rocket engines. Liquefied natural gas, which is based on methane, is seen as a promising motor fuel for internal combustion engines. One of the technical problems arising from the use of said cryogenic liquid is to provide containers for storage, transport and use in the propulsion system. In the design and operation of such vessels it is necessary to have reliable information about their temperature condition, on which depend the loss of cryogenic fluids due to evaporation and the stress-strain state of the structural elements of the containers.Uneven temperature distribution along the generatrix of the cylindrical thin-walled shell of rocket cryogenic tanks, in a localized zone of cryogenic liquid level leads to a curvature of the shell and reduce the permissible axle load in a hazard shell buckling in the preparation for the start of the missile in flight with an increasing acceleration. Moving the level of the cryogenic liquid during filling or emptying the tank at a certain combination of parameters results in an increase of the local temperature distribution nonuniformity.Along with experimental study of the shell temperature state of the cryogenic container, methods of mathematical modeling allow to have information needed for designing and testing the construction of cryogenic tanks. In this study a mathematical model is built taking into account features of heat transfer in a cryogenic container, including the boiling cryogenic liquid in the inner surface of the container. This mathematical model describes the temperature state of the thin-walled shell of cylindrical cryogenic tank during filling and emptying. The work also presents a quantitative analysis of this model in case of fixed liquid level, its movement at a constant speed, and harmonic oscillations relative to a middle position. The quantitative analysis of this model has allowed to find the limit options

  2. Energy system investment model incorporating heat pumps with thermal storage in buildings and buffer tanks

    DEFF Research Database (Denmark)

    Hedegaard, Karsten; Balyk, Olexandr

    2013-01-01

    options: passive heat storage in the building structure via radiator heating, active heat storage in concrete floors via floor heating, and use of thermal storage tanks for space heating and hot water. It is shown that the model is well qualified for analysing possibilities and system benefits...... be taken into account. In this study, we present a model that facilitates analysing individual heat pumps and complementing heat storages in integration with the energy system, while optimising both investments and operation. The model incorporates thermal building dynamics and covers various heat storage...

  3. Application of a Reliability Model Generator to a Pressure Tank System

    Institute of Scientific and Technical Information of China (English)

    Kathryn Stockwell; Sarah Dunnett

    2013-01-01

    A number of mathematical modelling techniques exist which are used to measure the performance of a given system,by assessing each individual component within the system.This can be used to determine the failure frequency or probability of the system.Software is available to undertake the task of analysing these mathematical models after an individual or group of individuals manually create the models.The process of generating these models is time consuming and reduces the impact of the model on the system design.One way to improve this would be to generate the model automatically.In this work,the procedure to automatically construct a model,based on Petri nets,for systems undergoing a phased-mission is applied to a pressure tank system,undertaking a four phase mission.

  4. Artificial Neural Networks Based Modeling and Control of Continuous Stirred Tank Reactor

    Directory of Open Access Journals (Sweden)

    R. S.M.N. Malar

    2009-01-01

    Full Text Available Continuous Stirred Tank Reactor (CSTR is one of the common reactors in chemical plant. Problem statement: Developing a model incorporating the nonlinear dynamics of the system warrants lot of computation. An efficient control of the product concentration can be achieved only through accurate model. Approach: In this study, attempts were made to alleviate the above mentioned problem using “Artificial Intelligence” (AI techniques. One of the AI techniques namely Artificial Neural Networks (ANN was used to model the CSTR incorporating its non-linear characteristics. Two nonlinear models based control strategies namely internal model control and direct inverse control were designed using the neural networks and applied to the control of isothermal CSTR. Results: The simulation results for the above control schemes with set point tracking were presented. Conclusion: Results indicated that neural networks can learn accurate models and give good non-linear control when model equations are not known.

  5. Seasonal affective disorder and non-seasonal affective disorders : results from the NESDA study

    NARCIS (Netherlands)

    Winthorst, Wim H; Roest, Annelieke M; Bos, Elisabeth H; Meesters, Ybe; Penninx, Brenda W J H; Nolen, Willem A; de Jonge, Peter

    BACKGROUND: Seasonal affective disorder (SAD) is considered to be a subtype of depression. AIMS: To compare the clinical picture of SAD to non-seasonal affective disorders (non-SADs). METHOD: Diagnoses according to the Diagnostic and Statistical Manual of Mental Disorders (DSM-IV) were established

  6. Hanford Tanks 241-C-202 and 241-C-203 Residual Waste Contaminant Release Models and Supporting Data

    Energy Technology Data Exchange (ETDEWEB)

    Deutsch, William J.; Krupka, Kenneth M.; Lindberg, Michael J.; Cantrell, Kirk J.; Brown, Christopher F.; Mattigod, Shas V.; Schaef, Herbert T.; Arey, Bruce W.

    2007-09-13

    As directed by Congress, the U. S. Department of Energy (DOE) established the Office of River Protection in 1998 to manage DOE's largest, most complex environmental cleanup project – retrieval of radioactive waste from Hanford tanks for treatment and eventual disposal. Sixty percent by volume of the nation's high-level radioactive waste is stored at Hanford in aging deteriorating tanks. If not cleaned up, this waste is a threat to the Columbia River and the Pacific Northwest. CH2M Hill Hanford Group, Inc., is the Office of River Protection's prime contractor responsible for the storage, retrieval, and disposal of Hanford's tank waste. As part of this effort, CH2M HILL Hanford Group, Inc. contracted with Pacific Northwest National Laboratory (PNNL) to develop release models for key contaminants that are present in residual sludge remaining after closure of Hanford Tanks 241-C-203 (C-203) and 241-C-204 (C-204). The release models were developed from data generated by laboratory characterization and testing of samples from these two tanks. These release models are being developed to support the tank closure risk assessments performed by CH2M HILL Hanford Group, Inc., for DOE.

  7. Computational modeling of the pressurization process in a NASP vehicle propellant tank experimental simulation

    Science.gov (United States)

    Sasmal, G. P.; Hochstein, J. I.; Wendl, M. C.; Hardy, T. L.

    1991-01-01

    A multidimensional computational model of the pressurization process in a slush hydrogen propellant storage tank was developed and its accuracy evaluated by comparison to experimental data measured for a 5 ft diameter spherical tank. The fluid mechanic, thermodynamic, and heat transfer processes within the ullage are represented by a finite-volume model. The model was shown to be in reasonable agreement with the experiment data. A parameter study was undertaken to examine the dependence of the pressurization process on initial ullage temperature distribution and pressurant mass flow rate. It is shown that for a given heat flux rate at the ullage boundary, the pressurization process is nearly independent of initial temperature distribution. Significant differences were identified between the ullage temperature and velocity fields predicted for pressurization of slush and those predicted for pressurization of liquid hydrogen. A simplified model of the pressurization process was constructed in search of a dimensionless characterization of the pressurization process. It is shown that the relationship derived from this simplified model collapses all of the pressure history data generated during this study into a single curve.

  8. Finite elements model of a rotating half-bridge belonging to a circular settling tank

    Science.gov (United States)

    Dascalescu, A. E.; Lazaroiu, G.; Scupi, A. A.; Oanta, E.

    2016-08-01

    A circular settling tank is an open reservoir used for the gravitational separation of the sludge and of the clarified water which is discharged in the launder which is mounted at the periphery of the basin. The extraction of the sludge is done by the use of a rotating half-bridge which sweeps the sludge, vacuums it using a system of scrapping blades and suction pipes, collects it in some local sludge chambers and pour it in a central collecting tank. The rotating half-bridge is a complex structure under a complex system of loads, therefore advanced instruments of investigation are required to assess the state of strains and stresses in this structure. Until now an analytical model was developed based on the hypotheses specific to the strength of materials academic discipline. The numerical models presented in the paper use the finite element method to determine the displacements of the main beam loaded by the weight of the structure and by the Archimedes’ forces. The results of the models developed so far are conclusive for the future directions of research which aims a higher degree of accuracy of the models and of the according research methodology.

  9. Consequence modeling of fire on Methane storage tanks in a gas refinery

    Directory of Open Access Journals (Sweden)

    Sara Shahedi ali abadi

    2016-06-01

    Full Text Available Introduction: using fossil fuels, some hazards such as explosion and fire are probable. This study was aimed to consequence modeling of fire on Methane storage tanks in a gas refinery using analyzing the risk, and modeling and evaluating the related consequences. Method: Hazard analysis by PHA was used to choosing the worst-case scenario. Then, causes of the scenario were determined by FTA. After that, consequence modeling by the PHAST software was applied for the consequence analysis. Results: Based on some criteria, the fire of methane gas tank (V-100 was selected as the worst-case scenario at the refinery. The qualitative fault tree showed three factors including mechanical, process, and human failures contribute in gas leakage. The leakage size and weather conditions were effective on the distance of radiation. Using consequence modeling, thermal radiation was considered as the major outcome of the incident. Finally, for outcome evaluating, probit equations were used to quantify losses and the percentage of fatalities due to the methane gas leakage and fire occurrence. The maximum number of fatalities caused by fire was obtained 23 persons. Conclusions: In conclusion, the methane gas vessel in the refinery can be considered as the main center of hazard, therefore the implementation of the safety rules, eliminating mechanical failures, personal protection and education, and Effective measures to prevent and fighting of fire are proposed for decreasing the probable losses and fatalities.

  10. MODELLING AND CONTROL OF CONTINUOUS STIRRED TANK REACTOR WITH PID CONTROLLER

    Directory of Open Access Journals (Sweden)

    Artur Wodołażski

    2016-09-01

    Full Text Available This paper presents a model of dynamics control for continuous stirred tank reactor (CSTR in methanol synthesis in a three-phase system. The reactor simulation was carried out for steady and transient state. Efficiency ratio to achieve maximum performance of the product per reactor unit volume was calculated. Reactor dynamics simulation in closed loop allowed to received data for tuning PID controller (proportional-integral-derivative. The results of the regulation process allow to receive data for optimum reactor production capacity, along with local hot spots eliminations or temperature runaway.

  11. Unit cell modeling in support of interim performance assessment for low level tank waste disposal

    Energy Technology Data Exchange (ETDEWEB)

    Kline, N.W., Westinghouse Hanford

    1996-08-01

    A unit cell model is used to simulate the base analysis case and related sensitivity cases for the interim performance assessment of low level tank waste disposal. Simulation case results are summarized in terms of fractional contaminant release rates to the vadose zone and to the water table at the unconfined aquifer. Results suggest that the crushed glass water conditioning layer at the top of the facility and the chemical retardation pad at the bottom of the facility can be important components of the facility. Results also suggest that the release rates to the water table are dominated by the release rate from the waste form.

  12. Hanford Site Tank 241-C-108 Residual Waste Contaminant Release Models and Supporting Data

    Energy Technology Data Exchange (ETDEWEB)

    Cantrell, Kirk J.; Krupka, Kenneth M.; Geiszler, Keith N.; Arey, Bruce W.; Schaef, Herbert T.

    2010-06-18

    This report presents the results of laboratory characterization, testing, and analysis for a composite sample (designated 20578) of residual waste collected from single-shell tank C-108 during the waste retrieval process after modified sluicing. These studies were completed to characterize concentration and form of contaminant of interest in the residual waste; assess the leachability of contaminants from the solids; and develop release models for contaminants of interest. Because modified sluicing did not achieve 99% removal of the waste, it is expected that additional retrieval processing will take place. As a result, the sample analyzed here is not expected to represent final retrieval sample.

  13. Veterinary dairy herd fertility service provision in seasonal and non-seasonal dairy industries - a comparison

    Directory of Open Access Journals (Sweden)

    Mee JF

    2010-04-01

    Full Text Available Abstract The decline in dairy herd fertility internationally has highlighted the limited impact of traditional veterinary approaches to bovine fertility management. Three questionnaire surveys were conducted at buiatrics conferences attended by veterinary practitioners on veterinary dairy herd fertility services (HFS in countries with a seasonal (Ireland, 47 respondents and non-seasonal breeding model (The Netherlands, 44 respondents and Portugal, 31 respondents. Of the 122 respondents, 73 (60% provided a HFS and 49 (40% did not. The majority (76% of all practitioners who responded stated that bovine fertility had declined in their practice clients' herds with inadequate cow management, inadequate nutrition and increased milk yield as the most important putative causes. The type of clients who adopted a herd fertility service were deemed more educated than average (70% of respondents, and/or had fertility problems (58% and/or large herds (53%. The main components of this service were routine postpartum examinations (95% of respondents, fertility records analysis (75% and ultrasound pregnancy examinations (69%. The number of planned visits per annum varied between an average of four in Ireland, where breeding is seasonal, and 23 in Portugal, where breeding is year-round. The benefits to both the practitioner and their clients from running a HFS were cited as better fertility, financial rewards and job satisfaction. For practitioners who did not run a HFS the main reasons given were no client demand (55% and lack of fertility records (33%. Better economic evidence to convince clients of the cost-benefit of such a service was seen as a major constraint to adoption of this service by 67% of practitioners.

  14. SINGLE-SHELL TANK INTEGRITY PROJECT ANALYSIS OF RECORD-PRELIMINARY MODELING PLAN FOR THERMAL AND OPERATING LOADS

    Energy Technology Data Exchange (ETDEWEB)

    RAST RS; RINKER MW; BAPANAALLI SK; DEIBLER JE; GUZMAN-LEONG CE; JOHNSON KI; KARRI NK; PILLI SP; SANBORN SE

    2010-10-22

    This document is a Phase I deliverable for the Single-Shell Tank Analysis of Record effort. This document is not the Analysis of Record. The intent of this document is to guide the Phase II detailed modeling effort. Preliminary finite element models for each of the tank types were developed and different case studies were performed on one or more of these tank types. Case studies evaluated include thermal loading, waste level variation, the sensitivity of boundary effects (soil radial extent), excavation slope or run to rise ratio, soil stratigraphic (property and layer thickness) variation at different farm locations, and concrete material property variation and their degradation under thermal loads. The preliminary analysis document reviews and preliminary modeling analysis results are reported herein. In addition, this report provides recommendations for the next phase of the SST AOR project, SST detailed modeling. Efforts and results discussed in this report do not include seismic modeling as seismic modeling is covered by a separate report. The combined results of both static and seismic models are required to complete this effort. The SST AOR project supports the US Department of Energy's (DOE) Office of River Protection (ORP) mission for obtaining a better understanding of the structural integrity of Hanford's SSTs. The 149 SSTs, with six different geometries, have experienced a range of operating histories which would require a large number of unique analyses to fully characterize their individual structural integrity. Preliminary modeling evaluations were conducted to determine the number of analyses required for adequate bounding of each of the SST tank types in the Detailed Modeling Phase of the SST AOR Project. The preliminary modeling was conducted in conjunction with the Evaluation Criteria report, Johnson et al. (2010). Reviews of existing documents were conducted at the initial stage of preliminary modeling. These reviews guided the topics

  15. Semi-analytical models of hydroelastic sloshing impact in tanks of liquefied natural gas vessels.

    Science.gov (United States)

    Ten, I; Malenica, Š; Korobkin, A

    2011-07-28

    The present paper deals with the methods for the evaluation of the hydroelastic interactions that appear during the violent sloshing impacts inside the tanks of liquefied natural gas carriers. The complexity of both the fluid flow and the structural behaviour (containment system and ship structure) does not allow for a fully consistent direct approach according to the present state of the art. Several simplifications are thus necessary in order to isolate the most dominant physical aspects and to treat them properly. In this paper, choice was made of semi-analytical modelling for the hydrodynamic part and finite-element modelling for the structural part. Depending on the impact type, different hydrodynamic models are proposed, and the basic principles of hydroelastic coupling are clearly described and validated with respect to the accuracy and convergence of the numerical results.

  16. Modeling of organic pollutant destruction in a stirred-tank reactor by ozonation

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Destruction of organic contaminants in water by ozonation is a gas-liquid process which involves ozone mass transfer and fast irreversible chemical reactions. Ozonation reactor design and process optimizing require the modeling of the gas-liquid interactions within the reactor. In this paper a theoretical model combining the fluid dynamic and reaction kineticparameters is proposed for predicting the destruction rates of organic pollutants in a semi-batch stirred-tank reactor by ozonation. A simple expression for the enhancement factor as ourprevious work (Cheng, 2000) has been applied to evaluate the chemical mass transfer coefficient in ozone absorption.2,4-dichlorophenol (2,4-DCP) and 2,6-DCP or their mixture are chosen as the model compounds for simulating, and the predicted DCP oundation item: The National Natural Science Foundation of China (No. 20006006) ncentrations are compared with some measured data.

  17. Modelling, Optimization and Optimal Control of Small Scale Stirred Tank Bioreactors

    Directory of Open Access Journals (Sweden)

    Mitko Petrov

    2004-10-01

    Full Text Available Models of the mass-transfer in a stirred tank bioreactor depending on general indexes of the processes of aeration and mixing in concrete simplifications of the hydrodynamic structure of the flows are developed. The offered combined model after parameters identification is used for optimization of the parameters of the apparatus construction. The optimization problem is solved by using of the fuzzy sets theory and in this way the unspecified as a result of the model simplification are read. In conclusion an optimal control of a fed-batch fermentation process of E. coli is completed by using Neuro-Dynamic programming. The received results after optimization show a considerable improvement of the mass-transfer indexes and the quantity indexes at the end of the process.

  18. Supporting document for the Southeast Quadrant historical tank content estimate report for SY-tank farm

    Energy Technology Data Exchange (ETDEWEB)

    Brevick, C.H.; Gaddis, L.A.; Consort, S.D. [Westinghouse Hanford Co., Richland, WA (United States)

    1995-12-31

    Historical Tank Content Estimate of the Southeast Quadrant provides historical evaluations on a tank by tank basis of the radioactive mixed wastes stored in the underground double-shell tanks of the Hanford 200 East and West Areas. This report summarizes historical information such as waste history, temperature profiles, psychrometric data, tank integrity, inventory estimates and tank level history on a tank by tank basis. Tank Farm aerial photos and in-tank photos of each tank are provided. A brief description of instrumentation methods used for waste tank surveillance are included. Components of the data management effort, such as Waste Status and Transaction Record Summary, Tank Layer Model, Supernatant Mixing Model, Defined Waste Types, and Inventory Estimates which generate these tank content estimates, are also given in this report.

  19. Hanford Tanks 241-C-203 and 241-C-204: Residual Waste Contaminant Release Model and Supporting Data

    Energy Technology Data Exchange (ETDEWEB)

    Deutsch, William J.; Krupka, Kenneth M.; Lindberg, Michael J.; Cantrell, Kirk J.; Brown, Christopher F.; Schaef, Herbert T.

    2004-10-28

    This report describes the development of release models for key contaminants that are present in residual sludge remaining after closure of Hanford Tanks 241-C-203 (C-203) and 241-C-204 (C-204). The release models were developed from data generated by laboratory characterization and testing of samples from these two tanks. Key results from this work are (1) future releases from the tanks of the primary contaminants of concern (99Tc and 238U) can be represented by relatively simple solubility relationships between infiltrating water and solid phases containing the contaminants; and (2) high percentages of technetium-99 in the sludges (20 wt% in C-203 and 75 wt% in C-204) are not readily water leachable, and, in fact, are very recalcitrant. This is similar to results found in related studies of sludges from Tank AY-102. These release models are being developed to support the tank closure risk assessments performed by CH2M HILL Hanford Group, Inc., for the U.S. Department of Energy.

  20. Hanford Tanks 241-C-203 and 241 C 204: Residual Waste Contaminant Release Model and Supporting Data

    Energy Technology Data Exchange (ETDEWEB)

    Deutsch, William J.; Krupka, Kenneth M.; Lindberg, Michael J.; Cantrell, Kirk J.; Brown, Christopher F.; Schaef, Herbert T.

    2007-05-23

    This report was revised in May 2007 to correct 90Sr values in Chapter 3. The changes were made on page 3.9, paragraph two and Table 3.10; page 3.16, last paragraph on the page; and Tables 3.21 and 3.31. The rest of the text remains unchanged from the original report issued in October 2004. This report describes the development of release models for key contaminants that are present in residual sludge remaining after closure of Hanford Tanks 241-C-203 (C-203) and 241-C-204 (C-204). The release models were developed from data generated by laboratory characterization and testing of samples from these two tanks. Key results from this work are (1) future releases from the tanks of the primary contaminants of concern (99Tc and 238U) can be represented by relatively simple solubility relationships between infiltrating water and solid phases containing the contaminants; and (2) high percentages of technetium-99 in the sludges (20 wt% in C-203 and 75 wt% in C-204) are not readily water leachable, and, in fact, are very recalcitrant. This is similar to results found in related studies of sludges from Tank AY-102. These release models are being developed to support the tank closure risk assessments performed by CH2M HILL Hanford Group, Inc., for the U.S. Department of Energy.

  1. Takagi Sugeno fuzzy expert model based soft fault diagnosis for two tank interacting system

    Directory of Open Access Journals (Sweden)

    Manikandan Pandiyan

    2014-09-01

    Full Text Available The inherent characteristics of fuzzy logic theory make it suitable for fault detection and diagnosis (FDI. Fault detection can benefit from nonlinear fuzzy modeling and fault diagnosis can profit from a transparent reasoning system, which can embed operator experience, but also learn from experimental and/or simulation data. Thus, fuzzy logic-based diagnostic is advantageous since it allows the incorporation of a-priori knowledge and lets the user understand the inference of the system. In this paper, the successful use of a fuzzy FDI based system, based on dynamic fuzzy models for fault detection and diagnosis of an industrial two tank system is presented. The plant data is used for the design and validation of the fuzzy FDI system. The validation results show the effectiveness of this approach.

  2. Tank Investigation of the EDO Model 142 Hydro-Ski Research Airplane

    Science.gov (United States)

    Ramsen, John A.; Wadlin, Kenneth L.; Gray, George R.

    1951-01-01

    A tank investigation has been conducted of a 1/10-size powered-dynamic model of the Edo model 142 hydra-ski research airplane. The results of tests of two configurations are presented: One included a large ski and a ski well; the other, a small ski without a well. Water take-offs would be possible with the available thrust for either configuration: however, the configuration with the large ski emerged sooner and had less resistance from ski emergence until take-off. Longitudinal stability and landing behavior in smooth water were satisfactory for both configurations. Some alteration to the design of the tail would be desirable in order to reduce the spray loads.

  3. A model to predict the permeation of type IV hydrogen tanks

    Energy Technology Data Exchange (ETDEWEB)

    Bayle, Julien; Perreux, Dominique; Chapelle, David; Thiebaud, Frederic [MaHyTec, Dole (France); Nardin, Philippe [Franche Comte Univ. (France)

    2010-07-01

    In the frame of the certification process of the type IV hydrogen storage tanks MaHyTec aims to manufacture, this innovative SME is developing a numerical model dedicated to the study of permeation issues. Such an approach aims at avoiding complicated, time-consuming and expensive testing. Experimental results obtained under real conditions can moreover be significantly influenced by the scattering of material properties and liner dimensions. From simple testing on small-size flat membranes, the model allows to predict the gas diffusion flow through the whole structure by means of numerous parameters. On every step, theory can be compared with the results obtained from the samples. This document presents a brief review of the mathematical theory describing gas diffusion and the different aspects of the study for better understanding the proposed approach. (orig.)

  4. Simulation of Fault Arc Based on Different Radiation Models in a Closed Tank

    Science.gov (United States)

    Li, Mei; Zhang, Junpeng; Hu, Yang; Zhang, Hantian; Wu, Yifei

    2016-05-01

    This paper focuses on the simulation of a fault arc in a closed tank based on the magneto-hydrodynamic (MHD) method, in which a comparative study of three radiation models, including net emission coefficients (NEC), semi-empirical model based on NEC as well as the P1 model, is developed. The pressure rise calculated by the three radiation models are compared to the measured results. Particularly when the semi-empirical model is used, the effect of different boundary temperatures of the re-absorption layer in the semi-empirical model on pressure rise is concentrated on. The results show that the re-absorption effect in the low-temperature region affects radiation transfer of fault arcs evidently, and thus the internal pressure rise. Compared with the NEC model, P1 and the semi-empirical model with 0.7pressure rise of the fault arc, where is an adjusted parameter involving the boundary temperature of the re-absorption region in the semi-empirical model. supported by National Key Basic Research Program of China (973 Program) (No. 2015CB251002), National Natural Science Foundation of China (Nos. 51221005, 51177124), the Fundamental Research Funds for the Central Universities, the Program for New Century Excellent Talents in University and Shaanxi Province Natural Science Foundation of China (No. 2013JM-7010)

  5. Simulation of Fault Arc Based on Different Radiation Models in a Closed Tank

    Institute of Scientific and Technical Information of China (English)

    LI Mei; ZHANG Junpeng; HU Yang; ZHANG Hantian; WU Yifei

    2016-01-01

    This paper focuses on the simulation of a fault arc in a closed tank based on the magneto-hydrodynamic (MHD) method,in which a comparative study of three radiation models,including net emission coefficients (NEC),semi-empirical model based on NEC as well as the P1 model,is developed.The pressure rise calculated by the three radiation models are compared to the measured results.Particularly when the semi-empirical model is used,the effect of different boundary temperatures of the re-absorption layer in the semi-empirical model on pressure rise is concentrated on.The results show that the re-absorption effect in the low-temperature region affects radiation transfer of fault arcs evidently,and thus the internal pressure rise.Compared with the NEC model,P1 and the semi-empirical model with 0.7 < α < 0.83 are more suitable to calculate the pressure rise of the fault arc,where is an adjusted parameter involving the boundary temperature of the re-absorption region in the semi-empirical model.

  6. Use of In-Situ Dynamic Measurements to Calibrate Analytical Models of RC-Elevated Water Tanks

    Directory of Open Access Journals (Sweden)

    H.M. Lopes

    2012-01-01

    Full Text Available Before establishing the priority settings for the reduction of seismic risk of water supply infrastructures, it is necessary to understand the dynamic behavior of elevated water tanks, which are components of those infrastructures. Among other information, the main frequencies of vibration of these structures must be estimated and the analytical models used in their analysis and design should reproduce the frequency values obtained by in-situ dynamic tests. This work focuses exclusively on reinforced concrete (RC elevated water tanks (200–750 m^3 of water at heights of 30–40 m, which are very common structures in the water supply systems in Portugal since the mid XXth century. This type of structures can also be seen in many regions around the world. First, a nationwide survey was conducted to determine the most common typologies in the country in terms of structural layout. Second, an in-situ campaign using ambient vibration as input was performed for a group of selected structures to determine the main frequencies of vibration and to identify modal shapes and damping values. Third, a finite element model of several different typologies was developed using the water simply as a concentrated mass at the top; the elastic properties of the model of the structure including the foundation were calibrated, so that the frequencies of various mode shapes obtained by the analytical model would match the frequencies of the real structure. Finally, an expression was derived to estimate the fundamental frequency of a group of elevated water tank typologies based on the total mass at the top of the supporting structure, which include the water, the global lateral stiffness, and the height of the tank. This study, providing important information on the frequencies of vibration of RC-elevated water tanks, contributes in a definite way to the analysis and design of such water tanks.

  7. Model of the hydrodynamic loads applied on a rotating halfbridge belonging to a circular settling tank

    Science.gov (United States)

    Dascalescu, A. E.; Lazaroiu, G.; Scupi, A. A.; Oanta, E.

    2016-08-01

    The rotating half-bridge of a settling tank is employed to sweep the sludge from the wastewater and to vacuum and sent it to the central collector. It has a complex geometry but the main beam may be considered a slender bar loaded by the following category of forces: concentrated forces produced by the weight of the scrapping system of blades, suction pipes, local sludge collecting chamber, plus the sludge in the horizontal sludge transporting pipes; forces produced by the access bridge; buoyant forces produced by the floating barrels according to Archimedes’ principle; distributed forces produced by the weight of the main bridge; hydrodynamic forces. In order to evaluate the hydrodynamic loads we have conceived a numerical model based on the finite volume method, using the ANSYS-Fluent software. To model the flow we used the equations of Reynolds Averaged Navier-Stokes (RANS) for liquids together with Volume of Fluid model (VOF) for multiphase flows. For turbulent model k-epsilon we used the equation for turbulent kinetic energy k and dissipation epsilon. These results will be used to increase the accuracy of the loads’ sub-model in the theoretical models, e. the finite element model and the analytical model.

  8. Dynamic one-dimensional modeling of secondary settling tanks and design impacts of sizing decisions.

    Science.gov (United States)

    Li, Ben; Stenstrom, Michael K

    2014-03-01

    As one of the most significant components in the activated sludge process (ASP), secondary settling tanks (SSTs) can be investigated with mathematical models to optimize design and operation. This paper takes a new look at the one-dimensional (1-D) SST model by analyzing and considering the impacts of numerical problems, especially the process robustness. An improved SST model with Yee-Roe-Davis technique as the PDE solver is proposed and compared with the widely used Takács model to show its improvement in numerical solution quality. The improved and Takács models are coupled with a bioreactor model to reevaluate ASP design basis and several popular control strategies for economic plausibility, contaminant removal efficiency and system robustness. The time-to-failure due to rising sludge blanket during overloading, as a key robustness indicator, is analyzed to demonstrate the differences caused by numerical issues in SST models. The calculated results indicate that the Takács model significantly underestimates time to failure, thus leading to a conservative design.

  9. Serial grey-box model of a stratified thermal tank for hierarchical control of a solar plant

    Energy Technology Data Exchange (ETDEWEB)

    Arahal, Manuel R. [Universidad de Sevilla, Dpto. de Ingenieria de Sistemas y Automatica, Camino de los Descubrimientos s/n, 41092 Sevilla (Spain); Cirre, Cristina M. [Convenio Universidad de Almeria-Plataforma Solar de Almeria, Ctra. Senes s/n, 04200 Tabernas, Almeria (Spain); Berenguel, Manuel [Universidad de Almeria, Dpto. Lenguajes y Computacion, Ctra. Sacramento s/n, 04120, Almeria (Spain)

    2008-05-15

    The ACUREX collector field together with a thermal storage tank and a power conversion system forms the Small Solar Power Systems plant of the Plataforma Solar de Almeria, a facility that has been used for research for the last 25 years. A simulator of the collector field produced by the last author has been available to and used as a test-bed for control strategies. Up to now, however, there is not a model for the whole plant. Such model is needed for hierarchical control schemes also proposed by the authors. In this paper a model of the thermal storage tank is derived using the Simultaneous Perturbation Stochastic Approximation technique to adjust the parameters of a serial grey-box model structure. The benefits of the proposed approach are discussed in the context of the intended use, requiring a model capable of simulating the behavior of the storage tank with low computational load and low error over medium to large horizons. The model is tested against real data in a variety of situations showing its performance in terms of simulation error in the temperature profile and in the usable energy stored in the tank. The results obtained demonstrate the viability of the proposed approach. (author)

  10. Zero phase sequence impedance and tank heating model for three phase three leg core type power transformers coupling magnetic field and electric circuit equations in finite element software

    Energy Technology Data Exchange (ETDEWEB)

    Ngnegueu, T.; Mailhot, M.; Munar, A. [Jeumont Schneider Transformateurs, Lyon (France); Sacotte, M. [France-Transfo. Voie romaine, Mezieres-Les-Metz (France)

    1995-05-01

    In this paper, the authors present a finite element model for the calculation of zero phase sequence reactance for three phase three leg core type power transformers. An axisymmetrical approximation is assumed. A simplified model is used to assess the tank`s hottest spot temperature.

  11. Dynamic one-dimensional modeling of secondary settling tanks and system robustness evaluation.

    Science.gov (United States)

    Li, Ben; Stenstrom, M K

    2014-01-01

    One-dimensional secondary settling tank models are widely used in current engineering practice for design and optimization, and usually can be expressed as a nonlinear hyperbolic or nonlinear strongly degenerate parabolic partial differential equation (PDE). Reliable numerical methods are needed to produce approximate solutions that converge to the exact analytical solutions. In this study, we introduced a reliable numerical technique, the Yee-Roe-Davis (YRD) method as the governing PDE solver, and compared its reliability with the prevalent Stenstrom-Vitasovic-Takács (SVT) method by assessing their simulation results at various operating conditions. The YRD method also produced a similar solution to the previously developed Method G and Enquist-Osher method. The YRD and SVT methods were also used for a time-to-failure evaluation, and the results show that the choice of numerical method can greatly impact the solution. Reliable numerical methods, such as the YRD method, are strongly recommended.

  12. Modeling the Dynamic Failure of Railroad Tank Cars Using a Physically Motivated Internal State Variable Plasticity/Damage Nonlocal Model

    Directory of Open Access Journals (Sweden)

    Fazle R. Ahad

    2013-01-01

    Full Text Available We used a physically motivated internal state variable plasticity/damage model containing a mathematical length scale to idealize the material response in finite element simulations of a large-scale boundary value problem. The problem consists of a moving striker colliding against a stationary hazmat tank car. The motivations are (1 to reproduce with high fidelity finite deformation and temperature histories, damage, and high rate phenomena that may arise during the impact accident and (2 to address the material postbifurcation regime pathological mesh size issues. We introduce the mathematical length scale in the model by adopting a nonlocal evolution equation for the damage, as suggested by Pijaudier-Cabot and Bazant in the context of concrete. We implement this evolution equation into existing finite element subroutines of the plasticity/failure model. The results of the simulations, carried out with the aid of Abaqus/Explicit finite element code, show that the material model, accounting for temperature histories and nonlocal damage effects, satisfactorily predicts the damage progression during the tank car impact accident and significantly reduces the pathological mesh size effects.

  13. Floc size distributions of suspended kaolinite in an advection transport dominated tank: measurements and modeling

    Science.gov (United States)

    Shen, Xiaoteng; Maa, Jerome P.-Y.

    2017-09-01

    In estuaries and coastal waters, floc size and its statistical distributions of cohesive sediments are of primary importance, due to their effects on the settling velocity and thus deposition rates of cohesive aggregates. The development of a robust flocculation model that includes the predictions of floc size distributions (FSDs), however, is still in a research stage. In this study, a one-dimensional longitudinal (1-DL) flocculation model along a streamtube is developed. This model is based on solving the population balance equation to find the FSDs by using the quadrature method of moments. To validate this model, a laboratory experiment is carried out to produce an advection transport-dominant environment in a cylindrical tank. The flow field is generated by a marine pump mounted at the bottom center, with its outlet facing upward. This setup generates an axially symmetric flow which is measured by an acoustic Doppler velocimeter (ADV). The measurement results provide the hydrodynamic input data required for this 1-DL model. The other measurement results, the FSDs, are acquired by using an automatic underwater camera system and the resulting images are analyzed to validate the predicted FSDs. This study shows that the FSDs as well as their representative sizes can be efficiently and reasonably simulated by this 1-DL model.

  14. Development of a CFD Model for Secondary Final Settling Tanks in Water Pollution Control Plants

    Science.gov (United States)

    Gong, Minwei; Xanthos, Savvas; Ramalingam, Krish; Fillos, John

    2007-11-01

    To assess performance and evaluate alternatives to improve efficiency of the New York City the Wards Island Water Pollution Control Plant (WPCP) FSTs at peak loads, a 3D CFD model has been developed. Fluent was utilized as the base platform, where sub-models of the Suspended Solids (SS), settling characteristics, density currents and SS flocculation were incorporated. This was supplemented by field and bench scale experiments to quantify the coefficients integral to the sub-models. Model calibration and validation have been carried out by using the extensive set of data collected. The model can be used to evaluate different modes of operation, alternate hydraulic and solids loading rates, as well as addition of auxiliary components such as baffles to improve process performance. The model is being used to compare potential benefits for different alternatives of design and operation of the existing FSTs. After comparing series of inlet baffles, a baffle with 4 horizontal and 7 vertical slots has been recommended for installation in the FSTs. Additional baffle type, configurations and locations within the tank are also being evaluated to improve the performance of the FSTs especially during periods of poor settling and peak flow conditions.

  15. A consistent modelling methodology for secondary settling tanks: a reliable numerical method.

    Science.gov (United States)

    Bürger, Raimund; Diehl, Stefan; Farås, Sebastian; Nopens, Ingmar; Torfs, Elena

    2013-01-01

    The consistent modelling methodology for secondary settling tanks (SSTs) leads to a partial differential equation (PDE) of nonlinear convection-diffusion type as a one-dimensional model for the solids concentration as a function of depth and time. This PDE includes a flux that depends discontinuously on spatial position modelling hindered settling and bulk flows, a singular source term describing the feed mechanism, a degenerating term accounting for sediment compressibility, and a dispersion term for turbulence. In addition, the solution itself is discontinuous. A consistent, reliable and robust numerical method that properly handles these difficulties is presented. Many constitutive relations for hindered settling, compression and dispersion can be used within the model, allowing the user to switch on and off effects of interest depending on the modelling goal as well as investigate the suitability of certain constitutive expressions. Simulations show the effect of the dispersion term on effluent suspended solids and total sludge mass in the SST. The focus is on correct implementation whereas calibration and validation are not pursued.

  16. Concentration-driven models revisited: towards a unified framework to model settling tanks in water resource recovery facilities.

    Science.gov (United States)

    Torfs, Elena; Martí, M Carmen; Locatelli, Florent; Balemans, Sophie; Bürger, Raimund; Diehl, Stefan; Laurent, Julien; Vanrolleghem, Peter A; François, Pierre; Nopens, Ingmar

    2017-02-01

    A new perspective on the modelling of settling behaviour in water resource recovery facilities is introduced. The ultimate goal is to describe in a unified way the processes taking place both in primary settling tanks (PSTs) and secondary settling tanks (SSTs) for a more detailed operation and control. First, experimental evidence is provided, pointing out distributed particle properties (such as size, shape, density, porosity, and flocculation state) as an important common source of distributed settling behaviour in different settling unit processes and throughout different settling regimes (discrete, hindered and compression settling). Subsequently, a unified model framework that considers several particle classes is proposed in order to describe distributions in settling behaviour as well as the effect of variations in particle properties on the settling process. The result is a set of partial differential equations (PDEs) that are valid from dilute concentrations, where they correspond to discrete settling, to concentrated suspensions, where they correspond to compression settling. Consequently, these PDEs model both PSTs and SSTs.

  17. Tank characterization reference guide

    Energy Technology Data Exchange (ETDEWEB)

    De Lorenzo, D.S.; DiCenso, A.T.; Hiller, D.B.; Johnson, K.W.; Rutherford, J.H.; Smith, D.J. [Los Alamos Technical Associates, Kennewick, WA (United States); Simpson, B.C. [Westinghouse Hanford Co., Richland, WA (United States)

    1994-09-01

    Characterization of the Hanford Site high-level waste storage tanks supports safety issue resolution; operations and maintenance requirements; and retrieval, pretreatment, vitrification, and disposal technology development. Technical, historical, and programmatic information about the waste tanks is often scattered among many sources, if it is documented at all. This Tank Characterization Reference Guide, therefore, serves as a common location for much of the generic tank information that is otherwise contained in many documents. The report is intended to be an introduction to the issues and history surrounding the generation, storage, and management of the liquid process wastes, and a presentation of the sampling, analysis, and modeling activities that support the current waste characterization. This report should provide a basis upon which those unfamiliar with the Hanford Site tank farms can start their research.

  18. COMPARISON OF EXPERIMENTS TO CFD MODELS FOR MIXING USING DUAL OPPOSING JETS IN TANKS WITH AND WITHOUT INTERNAL OBSTRUCTIONS

    Energy Technology Data Exchange (ETDEWEB)

    Leishear, R.; Poirier, M.; Lee, S.; Fowley, M.

    2012-06-26

    This paper documents testing methods, statistical data analysis, and a comparison of experimental results to CFD models for blending of fluids, which were blended using a single pump designed with dual opposing nozzles in an eight foot diameter tank. Overall, this research presents new findings in the field of mixing research. Specifically, blending processes were clearly shown to have random, chaotic effects, where possible causal factors such as turbulence, pump fluctuations, and eddies required future evaluation. CFD models were shown to provide reasonable estimates for the average blending times, but large variations -- or scatter -- occurred for blending times during similar tests. Using this experimental blending time data, the chaotic nature of blending was demonstrated and the variability of blending times with respect to average blending times were shown to increase with system complexity. Prior to this research, the variation in blending times caused discrepancies between CFD models and experiments. This research addressed this discrepancy, and determined statistical correction factors that can be applied to CFD models, and thereby quantified techniques to permit the application of CFD models to complex systems, such as blending. These blending time correction factors for CFD models are comparable to safety factors used in structural design, and compensate variability that cannot be theoretically calculated. To determine these correction factors, research was performed to investigate blending, using a pump with dual opposing jets which re-circulate fluids in the tank to promote blending when fluids are added to the tank. In all, eighty-five tests were performed both in a tank without internal obstructions and a tank with vertical obstructions similar to a tube bank in a heat exchanger. These obstructions provided scale models of vertical cooling coils below the liquid surface for a full scale, liquid radioactive waste storage tank. Also, different jet

  19. BLENDING STUDY FOR SRR SALT DISPOSITION INTEGRATION: TANK 50H SCALE-MODELING AND COMPUTER-MODELING FOR BLENDING PUMP DESIGN, PHASE 2

    Energy Technology Data Exchange (ETDEWEB)

    Leishear, R.; Poirier, M.; Fowley, M.

    2011-05-26

    The Salt Disposition Integration (SDI) portfolio of projects provides the infrastructure within existing Liquid Waste facilities to support the startup and long term operation of the Salt Waste Processing Facility (SWPF). Within SDI, the Blend and Feed Project will equip existing waste tanks in the Tank Farms to serve as Blend Tanks where 300,000-800,000 gallons of salt solution will be blended in 1.3 million gallon tanks and qualified for use as feedstock for SWPF. Blending requires the miscible salt solutions from potentially multiple source tanks per batch to be well mixed without disturbing settled sludge solids that may be present in a Blend Tank. Disturbing solids may be problematic both from a feed quality perspective as well as from a process safety perspective where hydrogen release from the sludge is a potential flammability concern. To develop the necessary technical basis for the design and operation of blending equipment, Savannah River National Laboratory (SRNL) completed scaled blending and transfer pump tests and computational fluid dynamics (CFD) modeling. A 94 inch diameter pilot-scale blending tank, including tank internals such as the blending pump, transfer pump, removable cooling coils, and center column, were used in this research. The test tank represents a 1/10.85 scaled version of an 85 foot diameter, Type IIIA, nuclear waste tank that may be typical of Blend Tanks used in SDI. Specifically, Tank 50 was selected as the tank to be modeled per the SRR, Project Engineering Manager. SRNL blending tests investigated various fixed position, non-rotating, dual nozzle pump designs, including a blending pump model provided by the blend pump vendor, Curtiss Wright (CW). Primary research goals were to assess blending times and to evaluate incipient sludge disturbance for waste tanks. Incipient sludge disturbance was defined by SRR and SRNL as minor blending of settled sludge from the tank bottom into suspension due to blending pump operation, where

  20. Think Tanks

    Science.gov (United States)

    2001-01-01

    A new inspection robot from Solex Robotics Systems was designed to eliminate hazardous inspections of petroleum and chemical storage tanks. The submersible robot, named Maverick, is used to inspect the bottoms of tanks, keeping the tanks operational during inspection. Maverick is able to provide services that will make manual tank inspections obsolete. While the inspection is conducted, Maverick's remote human operators remain safe outside of the tank. The risk to human health and life is now virtually eliminated. The risk to the environment is also minimal because there is a reduced chance of spillage from emptying and cleaning the tanks, where previously, tons of pollutants were released through the process of draining and refilling.

  1. Numerical Investigation of Thermal Distribution and Pressurization Behavior in Helium Pressurized Cryogenic Tank by Introducing a Multi-component Model

    Science.gov (United States)

    Lei, Wang; Yanzhong, Li; Zhan, Liu; Kang, Zhu

    An improved CFD model involving a multi-component gas mixturein the ullage is constructed to predict the pressurization behavior of a cryogenic tank considering the existence of pressurizing helium.A temperature difference between the local fluid and its saturation temperature corresponding to the vapor partial pressure is taken as the phase change driving force. As practical application of the model, hydrogen and oxygen tanks with helium pressurization arenumerically simulated by using themulti-component gas model. The results presentthat the improved model produce higher ullage temperature and pressure and lower wall temperaturethan those without multi-component consideration. The phase change has a slight influence on thepressurization performance due to the small quantities involved.

  2. Application of a diffusion-reaction kinetic model for the removal of 4-chlorophenol in continuous tank reactors.

    Science.gov (United States)

    Murcia, M D; Gómez, M; Bastida, J; Hidalgo, A M; Montiel, M C; Ortega, S

    2014-08-01

    A continuous tank reactor was used to remove 4-chlorophenol from aqueous solutions, using immobilized soybean peroxidase and hydrogen peroxide. The influence of operational variables (enzyme and substrate concentrations and spatial time) on the removal efficiency was studied. By using the kinetic law and the intrinsic kinetic parameters obtained in a previous work with a discontinuous tank reactor, the mass-balance differential equations of the transient state reactor model were solved and the theoretical conversion values were calculated. Several experimental series were used to obtain the values of the remaining model parameters by numerical calculation and using an error minimization algorithm. The model was checked by comparing the results obtained in some experiments (not used for the determination of the parameters) and the theoretical ones. The good concordance between the experimental and calculated conversion values confirmed that the design model can be used to predict the transient behaviour of the reactor.

  3. Numerical modeling of self-pressurization and pressure control by a thermodynamic vent system in a cryogenic tank

    Science.gov (United States)

    Majumdar, Alok; Valenzuela, Juan; LeClair, Andre; Moder, Jeff

    2016-03-01

    This paper presents a numerical model of a system-level test bed-the multipurpose hydrogen test bed (MHTB) using the Generalized Fluid System Simulation Program (GFSSP). MHTB is representative in size and shape of a space transportation vehicle liquid hydrogen propellant tank, and ground-based testing was performed at NASA Marshall Space Flight Center (MSFC) to generate data for cryogenic storage. GFSSP is a finite volume-based network flow analysis software developed at MSFC and used for thermofluid analysis of propulsion systems. GFSSP has been used to model the self-pressurization and ullage pressure control by the Thermodynamic Vent System (TVS). A TVS typically includes a Joule-Thompson (J-T) expansion device, a two-phase heat exchanger (HEX), and a mixing pump and liquid injector to extract thermal energy from the tank without significant loss of liquid propellant. For the MHTB tank, the HEX and liquid injector are combined into a vertical spray bar assembly. Two GFSSP models (Self-Pressurization and TVS) were separately developed and tested and then integrated to simulate the entire system. The Self-Pressurization model consists of multiple ullage nodes, a propellant node, and solid nodes; it computes the heat transfer through multilayer insulation blankets and calculates heat and mass transfer between the ullage and liquid propellant and the ullage and tank wall. A TVS model calculates the flow through a J-T valve, HEX, and spray and vent systems. Two models are integrated by exchanging data through User Subroutines of both models. Results of the integrated models have been compared with MHTB test data at a 50% fill level. Satisfactory comparison was observed between tests and numerical predictions.

  4. A thermodynamic tank model for studying the effect of higher hydrocarbons on natural gas storage in metal-organic frameworks

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, HD; Deria, P; Farha, OK; Hupp, JT; Snurr, RQ

    2015-01-01

    Metal-organic frameworks (MOFs) are promising materials for storing natural gas in vehicular applications. Evaluation of these materials has focused on adsorption of pure methane, although commercial natural gas also contains small amounts of higher hydrocarbons such as ethane and propane, which adsorb more strongly than methane. There is, thus, a possibility that these higher hydrocarbons will accumulate in the MOF after multiple operating (adsorption/desorption) cycles, and reduce the storage capacity. To study the net effect of ethane and propane on the performance of an adsorbed natural gas (ANG) tank, we developed a mathematical model based on thermodynamics and mass balance equations that describes the state of the tank at any instant. The required inputs are the pure-component isotherms, and mixture adsorption data are calculated using the Ideal Adsorbed Solution Theory (IAST). We focused on how the "deliverable energy'' provided by the ANG tank to the engine changed over 200 operating cycles for a sample of 120 MOF structures. We found that, with any MOF, the ANG tank performance monotonically declines during early operating cycles until a "cyclic steady state'' is reached. We determined that the best materials when the fuel is 100% methane are not necessarily the best when the fuel includes ethane and propane. Among the materials tested, some top MOFs are MOF-143 > NU-800 > IRMOF-14 > IRMOF-20 > MIL-100 > NU-125 > IRMOF-1 > NU-111. MOF-143 is predicted to deliver 5.43 MJ L-1 of tank to the engine once the cyclic steady state is reached. The model also provided insights that can assist in future work to discover more promising adsorbent materials for natural gas storage.

  5. A High Fidelity Computational Tool for Modeling Thermal Vent Systems in Cryogenic Tanks Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Control and management of cryogenic propellant tank pressures in low gravity is an important technical challenge to overcome for future long duration space missions....

  6. 3D MODELLING OF A SHRINK FITTED CONCAVE ENDED CYLINDRICAL TANK FOR AUTOMOTIVE INDUSTRY

    National Research Council Canada - National Science Library

    Mirela C Ghita; Constantin A Micu; Mihai D L Talu; Stefan D L Talu

    2013-01-01

      The aim of this work is to present a method that allows the optimal design of a shrink fitted concave ended cylindrical tank for the storage of methane gas, based on the application of the Finite Element Method (FEM...

  7. Modeling and analysis of chill and fill processes for the cryogenic storage and transfer engineering development unit tank

    Science.gov (United States)

    Hedayat, A.; Cartagena, W.; Majumdar, A. K.; LeClair, A. C.

    2016-03-01

    NASA's future missions may require long-term storage and transfer of cryogenic propellants. The Engineering Development Unit (EDU), a NASA in-house effort supported by both Marshall Space Flight Center (MSFC) and Glenn Research Center, is a cryogenic fluid management (CFM) test article that primarily serves as a manufacturing pathfinder and a risk reduction task for a future CFM payload. The EDU test article comprises a flight-like tank, internal components, insulation, and attachment struts. The EDU is designed to perform integrated passive thermal control performance testing with liquid hydrogen (LH2) in a test-like vacuum environment. A series of tests, with LH2 as a testing fluid, was conducted at Test Stand 300 at MSFC during the summer of 2014. The objective of this effort was to develop a thermal/fluid model for evaluating the thermodynamic behavior of the EDU tank during the chill and fill processes. The Generalized Fluid System Simulation Program, an MSFC in-house general-purpose computer program for flow network analysis, was utilized to model and simulate the chill and fill portion of the testing. The model contained the LH2 supply source, feed system, EDU tank, and vent system. The test setup, modeling description, and comparison of model predictions with the test data are presented.

  8. Study of Uranium Transport Utilizing Reactive Numerical Modeling and Experimental Data from Heterogeneous Intermediate-Scale Tanks

    Science.gov (United States)

    Rodriguez, D.; Miller, A.; Honeyman, B.

    2007-12-01

    The study of the transport of contaminants in groundwater is critical in order to mitigate risks to downstream receptors from sites where past releases of these contaminants has resulted in the degradation of the water quality of the underlying aquifer. In most cases, the fate and transport of these contaminants occurs in a chemically and physically heterogeneous environment; thereby making the prediction of the ultimate fate of these contaminants difficult. In order to better understand the fundamental processes that have the greatest effect on the transport of these contaminants, careful laboratory study must be completed in a controlled environment. Once the experimental data has been generated, the validation of numerical models may then be achieved. Questions on the management of contaminated sites may center on the long-term release (e.g., desorption, dissolution) behavior of contaminated geomedia. Data on the release of contaminants is often derived from bench-scale experiments or, in rare cases, through field-scale experiments. A central question, however, is how molecular-scale processes (e.g., bond breaking) are expressed at the macroscale. This presentation describes part of a collaborative study between the Colorado School of Mines, the USGS and Lawrence Berkeley National Lab on upscaling pore-scale processes to understanding field-scale observations. In the work described here, two experiments were conducted in two intermediate-scale tanks (2.44 m x 1.22 m x 7.6 cm and 2.44 m x 0.61 m x 7.6 cm) to generate data to quantify the processes of uranium dissolution and transport in fully saturated conditions, and to evaluate the ability of two reactive transport models to capture the relevant processes and predict U behavior at the intermediate scale. Each tank was designed so that spatial samples could be collected from the side of the tank, as well as samples from the effluent end of the tank. The larger tank was packed with a less than 2mm fraction of a

  9. A model of particle removal in a dissolved air flotation tank: importance of stratified flow and bubble size.

    Science.gov (United States)

    Lakghomi, B; Lawryshyn, Y; Hofmann, R

    2015-01-01

    An analytical model and a computational fluid dynamic model of particle removal in dissolved air flotation were developed that included the effects of stratified flow and bubble-particle clustering. The models were applied to study the effect of operating conditions and formation of stratified flow on particle removal. Both modeling approaches demonstrated that the presence of stratified flow enhanced particle removal in the tank. A higher air fraction was shown to be needed at higher loading rates to achieve the same removal efficiency. The model predictions showed that an optimum bubble size was present that increased with an increase in particle size.

  10. Modeling of Oxygen Transfer Correlations for Stirred Tank Bioreactor Agitated with Atypical Helical Ribbon Impeller

    Directory of Open Access Journals (Sweden)

    Mohd S. Mohamed

    2009-01-01

    Full Text Available Problem Statement: Mixing filamentous fungi entails delicate balance between promoting high volumetric oxygen transfer coefficient (kLa while keeping low hydrodynamic stresses in the microenvironment of cultures. This study examined the oxygen transfer capability of a prototype low shear helical impeller as a potential replacement for the standard Rushton turbine. Approach: The dependence of kLa upon specific power uptake, superficial gas velocity and apparent viscosity were examined under coalescent, non-coalescent and viscous pseudoplastic fluids scenario using dynamic gassing out technique. Subsequently, collected data were treated under historical data design of response surface methodology. Results: Three empirical power law kLa correlations were developed for each fluid. Correlation comparison with literature models for single turbine agitation suggest higher kLa augmentation within 1.5-3.6 folds for helical impeller in distilled water and as high as 78% improvement in electrolytes fluid. However impeller performance is comparatively 10% lower against theoretical kLa of triple turbines arrangement for power uptake between 0-1600 W m-3. In case of carboxymethylcellulose, better oxygen transfer is expected for design with higher proportionality of impeller-to-tank internal diameter. Conclusions: Helical impeller performance as gas-liquid contactor is comparable to single and triple Rushtons turbines, with superficial gas velocity proved to be more influential than power uptake in non-viscous liquids and vice versa in viscous pseudoplastic fluids.

  11. Modelling of the Bubble Size Distribution in an Aerated Stirred Tank: Theoretical and Numerical Comparison of Different Breakup Models

    Directory of Open Access Journals (Sweden)

    Kálal Zbyněk

    2014-09-01

    Full Text Available The main topic of this study is the mathematical modelling of bubble size distributions in an aerated stirred tank using the population balance method. The air-water system consisted of a fully baffled vessel with a diameter of 0.29 m, which was equipped with a six-bladed Rushton turbine. The secondary phase was introduced through a ring sparger situated under the impeller. Calculations were performed with the CFD software CFX 14.5. The turbulent quantities were predicted using the standard k-ε turbulence model. Coalescence and breakup of bubbles were modelled using the MUSIG method with 24 bubble size groups. For the bubble size distribution modelling, the breakup model by Luo and Svendsen (1996 typically has been used in the past. However, this breakup model was thoroughly reviewed and its practical applicability was questioned. Therefore, three different breakup models by Martínez-Bazán et al. (1999a, b, Lehr et al. (2002 and Alopaeus et al. (2002 were implemented in the CFD solver and applied to the system. The resulting Sauter mean diameters and local bubble size distributions were compared with experimental data.

  12. High efficient heat pump system using storage tanks to increase COP by means of the ISEC concept - Part 1: Model validation

    DEFF Research Database (Denmark)

    Rothuizen, Erasmus; Elmegaard, Brian; Markussen, Wiebke B.

    2015-01-01

    The purpose of the ISEC concept is to provide a high-efficient heat pump system for hot water production.The ISEC concept uses two storage tanks for the water, one discharged and one charged. Hot water for theindustrial process is tapped from the charged tank, while the other tank is charging....... Charging is done bycirculating the water in the tank through the condenser of a heat pump several times and thereby graduallyheating the water. The charging is done with a higher mass flow rate than the discharging to reach severalcirculations of the water during the time frame of one discharging....... This result in a lower condensingtemperature than if the water was heated in one step. Two test setups were built, one to test the performanceof the heat pump gradually heating the water and one to investigate the stratification in the storage tanks.Furthermore, a dynamic model of the system was implemented...

  13. Stochastic simulation modeling to determine time to detect Bovine Viral Diarrhea antibodies in bulk tank milk.

    Science.gov (United States)

    Foddai, Alessandro; Enøe, Claes; Krogh, Kaspar; Stockmarr, Anders; Halasa, Tariq

    2014-11-01

    A stochastic simulation model was developed to estimate the time from introduction of Bovine Viral Diarrhea Virus (BVDV) in a herd to detection of antibodies in bulk tank milk (BTM) samples using three ELISAs. We assumed that antibodies could be detected, after a fixed threshold prevalence of seroconverted milking cows was reached in the herd. Different thresholds were set for each ELISA, according to previous studies. For each test, antibody detection was simulated in small (70 cows), medium (150 cows) and large (320 cows) herds. The assays included were: (1) the Danish blocking ELISA, (2) the SVANOVIR(®)BVDV-Ab ELISA, and (3) the ELISA BVD/MD p80 Institute Pourquier. The validation of the model was mainly carried out by comparing the predicted incidence of persistently infected (PI) calves and the predicted detection time, with records from a BVD infected herd. Results showed that the SVANOVIR, which was the most efficient ELISA, could detect antibodies in the BTM of a large herd 280 days (95% prediction interval: 218; 568) after a transiently infected (TI) milking cow has been introduced into the herd. The estimated time to detection after introduction of one PI calf was 111 days (44; 605). With SVANOVIR ELISA the incidence of PIs and dead born calves could be limited and the impact of the disease on the animal welfare and income of farmers (before detection) could be minimized. The results from the simulation modeling can be used to improve the current Danish BVD surveillance program in detecting early infected herds. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Theoretical study of solar combisystems based on bikini tanks and tank-in-tank stores

    DEFF Research Database (Denmark)

    Yazdanshenas, Eshagh; Furbo, Simon

    2012-01-01

    Purpose - Low flow bikini solar combisystems and high flow tank-in-tank solar combisystems have been studied theoretically. The aim of the paper is to study which of these two solar combisystem designs is suitable for different houses. The thermal performance of solar combisystems based on the two...... different heat storage types is compared. Design/methodology/approach - The thermal performance of Low flow bikini solar combisystems and high flow tank-in-tank solar combisystems is calculated with the simulation program TRNSYS. Two different TRNSYS models based on measurements were developed and used....... Findings - Based on the calculations it is concluded that low flow solar combisystems based on bikini tanks are promising for low energy buildings, while solar combisystems based on tank-in-tank stores are attractive for the houses with medium heating demand and old houses with high heating demand...

  15. Model predictive control for a smart solar tank based on weather and consumption forecasts

    DEFF Research Database (Denmark)

    Halvgaard, Rasmus; Bacher, Peder; Perers, Bengt

    2012-01-01

    can also be heated by electric heating elements if necessary, but the electricity costs of operating these heating elements should be minimized. Consequently, the heating elements should be used in periods with cheap electricity. It is proposed to integrate a price-sensitive control to enable...... and the heat consumption in a residential house. The storage tank provides heat in periods where there is low solar radiation and stores heat when there is surplus solar heat. The forecasts of consumption patterns were based on data obtained from meters in a group of single-family houses in Denmark. The tank...... the storage tank to serve a smart energy system in which flexible consumers are expected to help balance fluctuating renewable energy sources like wind and solar. Through simulations, the impact of applying Economic MPC shows annual electricity cost savings up to 25-30%....

  16. Lead us not into tanktation: a simulation modelling approach to gain insights into incentives for sporting teams to tank.

    Directory of Open Access Journals (Sweden)

    Geoffrey N Tuck

    Full Text Available Annual draft systems are the principal method used by teams in major sporting leagues to recruit amateur players. These draft systems frequently take one of three forms: a lottery style draft, a weighted draft, or a reverse-order draft. Reverse-order drafts can create incentives for teams to deliberately under-perform, or tank, due to the perceived gain from obtaining quality players at higher draft picks. This paper uses a dynamic simulation model that captures the key components of a win-maximising sporting league, including the amateur player draft, draft choice error, player productivity, and between-team competition, to explore how competitive balance and incentives to under-perform vary according to league characteristics. We find reverse-order drafts can lead to some teams cycling between success and failure and to other teams being stuck in mid-ranking positions for extended periods of time. We also find that an incentive for teams to tank exists, but that this incentive decreases (i as uncertainty in the ability to determine quality players in the draft increases, (ii as the number of teams in the league reduces, (iii as team size decreases, and (iv as the number of teams adopting a tanking strategy increases. Simulation models can be used to explore complex stochastic dynamic systems such as sports leagues, where managers face difficult decisions regarding the structure of their league and the desire to maintain competitive balance.

  17. Temperature and flow measurements on near-freezing aviation fuels in a wing-tank model

    Science.gov (United States)

    Friedman, R.; Stockemer, F. J.

    1980-01-01

    Freezing behavior, pumpability, and temperature profiles for aviation turbine fuels were measured in a 190-liter tank, to simulate internal temperature gradients encountered in commercial airplane wing tanks. Two low-temperature situations were observed. Where the bulk of the fuel is above the specification freezing point, pumpout of the fuel removes all fuel except a layer adhering to the bottom chilled surfaces, and the unpumpable fraction depends on the fuel temperature near these surfaces. Where the bulk of the fuel is at or below the freezing point, pumpout ceases when solids block the pump inlet, and the unpumpable fraction depends on the overall average temperature.

  18. Analysis of the possibility of applying a condition-based maintenance model on an example of tank weapons

    Directory of Open Access Journals (Sweden)

    Igor J. Epler

    2013-12-01

    Full Text Available For any modern army it is very important to continuously maintain a high degree of operational (combat readiness (availability in order to maximize the effectiveness of the use of technical systems. Since determination and prediction of technical states and failures of technical systems in engineering, especially in armament, are difficult due to the impossibility of continuous condition monitoring with appropriate measuring equipment there is a need for a maintenance model that would be most helpful in taking timely action maintenance. In this paper, the subject of research is a model of maintenance of the M-84 tank  weapoons systems.   IntroductionThe M-84 tank is one of the most promising technical systems in the Serbian Army. Its use and modifications are foreseen in the next ten years. The  M-84 is characterized by good tactical and technical characteristics. It has a powerful 125 mm cannon, coupled 7.62 mm machine gun and 12.7 mm anti-aircraft machine gun. The M-84 tank has an automatic battery charger and a fire control system. The fire control system enables fast target tracking and stabilization of the cannon barrel, which is a prerequisite for timely and favorable effect on the target. There are certain ambiguities in the existing model of maintenance of tank weapons.   Technical diagnostics Technical diagnostics, as a part of the process of condition-based maintenance, should determine technical conditions of components or technical systems with certain accuracy at a point in time.   Maintenance strategy A maintenance strategy can be defined as a variant of a maintenance system determined by a concept, organization and character of maintenance procedures, as well as the relationship between the various levels at which maintenance is performed. It is defined for technical system parts, individual technical systems and for system maintenance as a whole. The basic maintenance strategies implemented today are: -      corrective

  19. Nitrogen tank

    CERN Multimedia

    2006-01-01

    Wanted The technical file about the pressure vessel RP-270 It concerns the Nitrogen tank, 60m3, 22 bars, built in 1979, and installed at Point-2 for the former L3 experiment. If you are in possession of this file, or have any files about an equivalent tank (probably between registered No. RP-260 and -272), please contact Marc Tavlet, the ALICE Glimos.

  20. Nitrogen tank

    CERN Document Server

    2006-01-01

    Wanted The technical file about the pressure vessel RP-270 It concerns the Nitrogen tank, 60m3, 22 bars, built in 1979, and installed at Point-2 for the former L3 experiment. If you are in possession of this file, or have any files about an equivalent tank (probably between registered No. RP-260 and -272), please contact Marc Tavlet, the ALICE Glimos.

  1. Surface wave modelling and simulation for wave tanks and coastal areas

    NARCIS (Netherlands)

    Groesen, van E. (Brenny); Bunnik, T.; Andonowati,

    2011-01-01

    For testing ships and offshore structures in hydrodynamic laboratories, the sea and ocean states should be represented as realistic as possible in the wave tanks in which the scaled experiments are executed. To support efficient testing, accurate software that determines and translates the required

  2. Thermal stratification in a hot water tank established by heat loss from the tank

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2012-01-01

    This paper presents numerical investigations of thermal stratification in a vertical cylindrical hot water tank established by standby heat loss from the tank. The transient fluid flow and heat transfer in the tank during cooling caused by standby heat loss are calculated by means of validated...... computational fluid dynamics (CFD) models. The measured heat loss coefficient for the different parts of the tank is used as input to the CFD model. Parametric studies are carried out using the validated models to investigate the influence on thermal stratification of the tank by the downward flow...... and the corresponding upward flow in the central parts of the tank. Tank design parameters such as tank volume, height to diameter ratio and insulation and different initial conditions of the tank are investigated.It is elucidated how thermal stratification in the tank is influenced by the natural convection and how...

  3. Significance of uncertainties derived from settling tank model structure and parameters on predicting WWTP performance - A global sensitivity analysis study

    DEFF Research Database (Denmark)

    Ramin, Elham; Sin, Gürkan; Mikkelsen, Peter Steen

    2011-01-01

    Uncertainty derived from one of the process models – such as one-dimensional secondary settling tank (SST) models – can impact the output of the other process models, e.g., biokinetic (ASM1), as well as the integrated wastewater treatment plant (WWTP) models. The model structure and parameter...... uncertainty of settler models can therefore propagate, and add to the uncertainties in prediction of any plant performance criteria. Here we present an assessment of the relative significance of secondary settling model performance in WWTP simulations. We perform a global sensitivity analysis (GSA) based....... The outcome of this study contributes to a better understanding of uncertainty in WWTPs, and explicitly demonstrates the significance of secondary settling processes that are crucial elements of model prediction under dry and wet-weather loading conditions....

  4. A General Tank Test of a Model of the Hull of the British Singapore IIC Flying Boat

    Science.gov (United States)

    Dawson, John R; Truscott, Starr

    1936-01-01

    A general test was made in the N.A.C.A. tank of a 1/12-size model of the hull of the British Singapore IIC flying boat loaned by the Director of Research, British Air Ministry. The results are given in charts and are compared with the results of tests of a model of an American flying-boat hull, the Sikorsky S-40. The Singapore hull has a greater hump resistance but a much lower high-speed resistance than the S-40.

  5. Estimation of Catchment Transit Time in Fuji River Basin by using an improved Tank model

    Science.gov (United States)

    Wenchao, M.; Yamanaka, T.; Wakiyama, Y.; Wang, P.

    2013-12-01

    As an important parameter that reflects the characteristics of catchments, the catchment transit time (CTT) has been given much more widely attentions especially in recent years. The CTT is defined as the time water spends travelling through a catchment to the stream network [1], and it describes how catchments retain and release water and solutes and thus control geochemical and biogeochemical cycling and contamination persistence [2]. The objectives of the present study are to develop a new approach for estimating CTT without prior information on such TTD functions and to apply it to the Fuji River basin in the Central Japan Alps Region. In this study, an improved Tank model was used to compute mean CTT and TTD functions simultaneously. It involved water fluxes and isotope mass balance. Water storage capacity in the catchment, which strongly affects CTT, is reflected in isotope mass balance more sensitively than in water fluxes. A model calibrated with observed discharge and isotope data is used for virtual age tracer computation to estimate CTT. This model does not only consider the hydrological data and physical process of the research area but also reflects the actual TTD with considering the geological condition, land use and the other catchment-hydrological conditions. For the calibration of the model, we used river discharge record obtained by the Ministry of Land, Infrastructure and Transportation, and are collecting isotope data of precipitation and river waters monthly or semi-weekly. Three sub-catchments (SC1~SC3) in the Fuji River basin was selected to test the model with five layers: the surface layer, upper-soil layer, lower-soil layer, groundwater aquifer layer and bedrock layer (Layer 1- Layer 5). The evaluation of the model output was assessed using Nash-Sutcliffe efficiency (NSE), root mean square error-observations standard deviation ratio (RSR), and percent bias (PBIAS). Using long time-series of discharge records for calibration, the simulated

  6. Numerical Modeling of the Effect of Thawing of Soil in the Area of Placing Tanks for Storage Fuel of Thermal Power Plants and Boiler

    Directory of Open Access Journals (Sweden)

    Polovnikov V.Yu.

    2016-01-01

    Full Text Available This paper describes the numerical modeling of heat transfer in the area placing of the tank for storage fuel of thermal power plant and boiler with considering the influence of thawing of the soil. We have established that the thawing of the soil in the area of placing of the tank for storage fuel of thermal power plant and boiler have little effect on the change of heat loss.

  7. Comparison of the 1D flux theory with a 2D hydrodynamic secondary settling tank model.

    Science.gov (United States)

    Ekama, G A; Marais, P

    2004-01-01

    The applicability of the 1D idealized flux theory (1DFT) for design of secondary settling tanks (SSTs) is evaluated by comparing its predicted maximum surface overflow (SOR) and solids loading (SLR) rates with that calculated from the 2D hydrodynamic model SettlerCAD using as a basis 35 full scale SST stress tests conducted on different SSTs with diameters from 30 to 45m and 2.25 to 4.1 m side water depth, with and without Stamford baffles. From the simulations, a relatively consistent pattern appeared, i.e. that the 1DFT can be used for design but its predicted maximum SLR needs to be reduced by an appropriate flux rating, the magnitude of which depends mainly on SST depth and hydraulic loading rate (HLR). Simulations of the sloping bottom shallow (1.5-2.5 m SWD) Dutch SSTs tested by STOWa and the Watts et al. SST, all with doubled SWDs, and the Darvill new (4.1 m) and old (2.5 m) SSTs with interchanged depths, were run to confirm the sensitivity of the flux rating to depth and HLR. Simulations with and without a Stamford baffle were also done. While the design of the internal features of the SST, such as baffling, have a marked influence on the effluent SS concentration for underloaded SSTs, these features appeared to have only a small influence on the flux rating, i.e. capacity, of the SST, In the meantime until more information is obtained, it would appear that from the simulations so far that the flux rating of 0.80 of the 1DFT maximum SLR recommended by Ekama and Marais remains a reasonable value to apply in the design of full scale SSTs--for deep SSTs (4 m SWD) the flux rating could be increased to 0.85 and for shallow SSTs (2.5 m SWD) decreased to 0.75. It is recommended that (i) while the apparent interrelationship between SST flux rating and depth suggests some optimization of the volume of the SST, that this be avoided and that (ii) the depth of the SST be designed independently of the surface area as is usually the practice and once selected, the

  8. Surface wave modelling and simulation for wave tanks and coastal areas

    OpenAIRE

    Groesen, van, E.; Bunnik, T.; Andonowati

    2011-01-01

    For testing ships and offshore structures in hydrodynamic laboratories, the sea and ocean states should be represented as realistic as possible in the wave tanks in which the scaled experiments are executed. To support efficient testing, accurate software that determines and translates the required wave maker motion into the downstream waves is very helpful. This paper describes an efficient hybrid spatial-spectral code that can deal with simulations above flat and varying bottom. The accurac...

  9. Septic tank additive impacts on microbial populations.

    Science.gov (United States)

    Pradhan, S; Hoover, M T; Clark, G H; Gumpertz, M; Wollum, A G; Cobb, C; Strock, J

    2008-01-01

    Environmental health specialists, other onsite wastewater professionals, scientists, and homeowners have questioned the effectiveness of septic tank additives. This paper describes an independent, third-party, field scale, research study of the effects of three liquid bacterial septic tank additives and a control (no additive) on septic tank microbial populations. Microbial populations were measured quarterly in a field study for 12 months in 48 full-size, functioning septic tanks. Bacterial populations in the 48 septic tanks were statistically analyzed with a mixed linear model. Additive effects were assessed for three septic tank maintenance levels (low, intermediate, and high). Dunnett's t-test for tank bacteria (alpha = .05) indicated that none of the treatments were significantly different, overall, from the control at the statistical level tested. In addition, the additives had no significant effects on septic tank bacterial populations at any of the septic tank maintenance levels. Additional controlled, field-based research iswarranted, however, to address additional additives and experimental conditions.

  10. AIR AND RADON PATHWAY MODELING FOR THE F AREA TANK FARM

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, K.; Phifer, M.

    2010-07-30

    An air and radon pathways analysis was conducted for the F-Area Tank Farm (FTF) to estimate the flux of volatile radionuclides and radon at the ground surface due to residual waste remaining in the tanks following closure. This analysis was used as the basis to estimate the dose to the maximally exposed individual (MEI) for the air pathway per Curie (Ci) of each radionuclide remaining in the combined FTF waste tanks. For the air pathway analysis, several gaseous radionuclides were considered. These included carbon-14 (C-14), chlorine-36 (Cl-36), iodine-129 (I-129), selenium-79 (Se-79), antimony-125 (Sb-125), tin-126 (Sn-126), tritium (H-3), and technetium-99 (Tc-99). The dose to the MEI was estimated at the SRS Boundary during the 100 year institutional control period. For the 10,000 year post closure compliance period, the dose to the MEI was estimated at the 100 m compliance point. Additionally, the dose to the MEI was estimated at a seepage outcrop located 1600 m from the facility. For the radon pathway analysis, five parent radionuclides and their progeny were analyzed. These parent radionuclides included uranium-238 (U-238), plutonium-238 (Pu-238), uranium-234 (U-234), thorium-230 (Th-230), and radium-226 (Ra-226). The peak flux of radon-222 due to each parent radionuclide was estimated for the simulation period of 10,100 years.

  11. Modelling pollutants dispersion and plume rise from large hydrocarbon tank fires in neutrally stratified atmosphere

    Science.gov (United States)

    Argyropoulos, C. D.; Sideris, G. M.; Christolis, M. N.; Nivolianitou, Z.; Markatos, N. C.

    2010-02-01

    Petrochemical industries normally use storage tanks containing large amounts of flammable and hazardous substances. Therefore, the occurrence of a tank fire, such as the large industrial accident on 11th December 2005 at Buncefield Oil Storage Depots, is possible and usually leads to fire and explosions. Experience has shown that the continuous production of black smoke from these fires due to the toxic gases from the combustion process, presents a potential environmental and health problem that is difficult to assess. The goals of the present effort are to estimate the height of the smoke plume, the ground-level concentrations of the toxic pollutants (smoke, SO 2, CO, PAHs, VOCs) and to characterize risk zones by comparing the ground-level concentrations with existing safety limits. For the application of the numerical procedure developed, an external floating-roof tank has been selected with dimensions of 85 m diameter and 20 m height. Results are presented and discussed. It is concluded that for all scenarios considered, the ground-level concentrations of smoke, SO 2, CO, PAHs and VOCs do not exceed the safety limit of IDLH and there are no "death zones" due to the pollutant concentrations.

  12. Modeling and Controlling Flow Transient in Pipeline Systems: Applied for Reservoir and Pump Systems Combined with Simple Surge Tank

    Directory of Open Access Journals (Sweden)

    Itissam ABUIZIAH

    2014-03-01

    Full Text Available When transient conditions (water hammer exist, the life expectancy of the system can be adversely impacted, resulting in pump and valve failures and catastrophic pipe rupture. Hence, transient control has become an essential requirement for ensuring safe operation of water pipeline systems. To protect the pipeline systems from transient effects, an accurate analysis and suitable protection devices should be used. This paper presents the problem of modeling and simulation of transient phenomena in hydraulic systems based on the characteristics method. Also, it provides the influence of using the protection devices to control the adverse effects due to excessive and low pressure occuring in the transient. We applied this model for two main pipeline systems: Valve and pump combined with a simple surge tank connected to reservoir. The results obtained by using this model indicate that the model is an efficient tool for water hammer analysis. Moreover, using a simple surge tank reduces the unfavorable effects of transients by reducing pressure fluctuations.

  13. Original analytical model of the hydrodynamic loads applied on the half-bridge of a circular settling tank

    Science.gov (United States)

    Oanta, Emil M.; Dascalescu, Anca-Elena; Sabau, Adrian

    2016-12-01

    The paper presents an original analytical model of the hydrodynamic loads applied on the half-bridge of a circular settling tank. The calculus domain is defined using analytical geometry and the calculus of the local dynamic pressure is based on the radius from the center of the settling tank to the current area, i.e. the relative velocity of the fluid and the depth where the current area is located, i.e. the density of the fluid. Calculus of the local drag forces uses the discrete frontal cross sectional areas of the submerged structure in contact with the fluid. In the last stage is performed the reduction of the local drag forces in the appropriate points belonging to the main beam. This class of loads is producing the flexure of the main beam in a horizontal plane and additional twisting moments along this structure. Taking into account the hydrodynamic loads, the results of the theoretical models, i.e. the analytical model and the finite element model, may have an increased accuracy.

  14. Underground Storage Tanks - Storage Tank Locations

    Data.gov (United States)

    NSGIC Education | GIS Inventory — A Storage Tank Location is a DEP primary facility type, and its sole sub-facility is the storage tank itself. Storage tanks are aboveground or underground, and are...

  15. Tank tests of two models of flying-boat hulls to determine the effect of ventilating the step

    Science.gov (United States)

    Dawson, John R

    1937-01-01

    The results of tests made in the N.A.C.A. tank on two models of flying-boat hulls to determine the effect of ventilating the step are given graphically. The step of N.A.C.A. model 11-C was ventilated in several different ways and it was found that the resistance of the normal form is not appreciably affected by artificial ventilation in any of the forms tried. Further tests made with the depth of the step of model 11-C reduced likewise show no appreciable effect on the resistance from ventilation of the step. Tests were made on a model of the hull of the Navy P3M-1 flying-boat hull both with and without ventilation of the step. It was found that the discontinuity which is obtained in the resistance curves of this model is eliminated by ventilating the step.

  16. Risk assessment and consequence modeling of BLEVE explosion wave phenomenon of LPG spherical tank in a refinery

    Directory of Open Access Journals (Sweden)

    Mohammad Kamaei

    2016-06-01

    Full Text Available Introduction: Although human industrial activities are as a part of efforts to achieve greater prosperity, the risks related to these activities are also expanding. Hazard identification and risk assessment in the oil and gas industries are essential to reduce the frequency and severity of accidents and minimize damage to people and property before their occurrence. The aim of this study was to evaluate the liquefied and pressurized petroleum gas spherical tanks in a refinery and assessing the risks of Boiling Liquid Expanding Vapor Explosion (BLEVE phenomenon. Material and Method: In this study, the risks of BLEVE phenomenon were assessed, using the Bowtie method. The consequences of explosion wave phenomenon and the resulting wave quantity and its impacts on the neighboring machineries and equipment were analyzed. PHAST software version 6.54 has been used for modeling the BLEVE phenomenon. Result: In this evaluation, generally five causes and two consequences were identified for BLEVE phenomenon. In order to reduce its consequences, forty-three controlling measures were introduced to prevent the BLEVE phenomenon and the impacts of 31 control measures were identified. According to the conducted analysis, it was found that the spherical tank blast wave caused by LPG can lead to explosion of close located tanks which can create a chain of explosions. Conclusion: The results of modeling and risk assessment can be used to identify the BLEVE phenomenon causes and its effects on nearby people and equipment. Based on these results, preventive controlling measures can be implemented and also be determined by adopting proper design and layout, margin of safety for personnel, equipment and accessories.

  17. Observatories, think tanks, and community models in the hydrologic and environmental sciences: How does it affect me?

    Science.gov (United States)

    Torgersen, Thomas

    2006-06-01

    Multiple issues in hydrologic and environmental sciences are now squarely in the public focus and require both government and scientific study. Two facts also emerge: (1) The new approach being touted publicly for advancing the hydrologic and environmental sciences is the establishment of community-operated "big science" (observatories, think tanks, community models, and data repositories). (2) There have been important changes in the business of science over the last 20 years that make it important for the hydrologic and environmental sciences to demonstrate the "value" of public investment in hydrological and environmental science. Given that community-operated big science (observatories, think tanks, community models, and data repositories) could become operational, I argue that such big science should not mean a reduction in the importance of single-investigator science. Rather, specific linkages between the large-scale, team-built, community-operated big science and the single investigator should provide context data, observatory data, and systems models for a continuing stream of hypotheses by discipline-based, specialized research and a strong rationale for continued, single-PI ("discovery-based") research. I also argue that big science can be managed to provide a better means of demonstrating the value of public investment in the hydrologic and environmental sciences. Decisions regarding policy will still be political, but big science could provide an integration of the best scientific understanding as a guide for the best policy.

  18. Seasonal affective disorder and non-seasonal affective disorders: results from the NESDA study.

    Science.gov (United States)

    Winthorst, Wim H; Roest, Annelieke M; Bos, Elisabeth H; Meesters, Ybe; Penninx, Brenda W J H; Nolen, Willem A; de Jonge, Peter

    2017-07-01

    Seasonal affective disorder (SAD) is considered to be a subtype of depression. To compare the clinical picture of SAD to non-seasonal affective disorders (non-SADs). Diagnoses according to the Diagnostic and Statistical Manual of Mental Disorders (DSM-IV) were established in 2185 participants of the Netherlands Study of Depression and Anxiety. The Seasonal Pattern Assessment Questionnaire was administered to diagnose SAD. Symptoms of depression and anxiety were measured with the Inventory of Depressive Symptoms, the Beck Anxiety Inventory and the Fear Questionnaire. Participants with SAD, participants with a lifetime bipolar disorder and participants with a lifetime comorbid anxiety and depressive disorder scored highest in terms of psychopathology in the past year. The seasonal distribution of major depressive episodes was not different for participants with or without SAD. SAD may be a measure of severity of depression with a subjectively perceived worsening of symptoms in the winter months. Y.M. has received research funding and served as a consultant for Royal Philips Electronics NV and The Litebook Company Ltd. W.A.N. has received grants from the Netherlands Organization for Health Research and Development, the European Union, the Stanley Medical Research Institute, Astra Zeneca, Eli Lilly, GlaxoSmithKline and Wyeth; has received honoraria/speaker's fees from Astra Zeneca, Pfizer, Servier and Wyeth; and has served in advisory boards for Astra Zeneca, Pfizer and Servier. © The Royal College of Psychiatrists 2017. This is an open access article distributed under the terms of the Creative Commons Non-Commercial, No Derivatives (CC BY-NC-ND) license.

  19. Linear and Non-linear Multi-Input Multi-Output Model Predictive Control of Continuous Stirred Tank Reactor

    Directory of Open Access Journals (Sweden)

    Muayad Al-Qaisy

    2013-04-01

    Full Text Available In this article, multi-input multi-output (MIMO linear model predictive controller (LMPC based on state space model and nonlinear model predictive controller based on neural network (NNMPC are applied on a continuous stirred tank reactor (CSTR. The idea is to have a good control system that will be able to give optimal performance, reject high load disturbance, and track set point change. In order to study the performance of the two model predictive controllers, MIMO Proportional-Integral-Derivative controller (PID strategy is used as benchmark. The LMPC, NNMPC, and PID strategies are used for controlling the residual concentration (CA and reactor temperature (T. NNMPC control shows a superior performance over the LMPC and PID controllers by presenting a smaller overshoot and shorter settling time.

  20. Numerical Simulation of the Whole Three—Dimensional Flow in a Stirred Tank with Anisotropic Algebraic Stress Model

    Institute of Scientific and Technical Information of China (English)

    SUNHaiyan; WANGWeijing; 等

    2002-01-01

    In accordance to the anisotropic feature of turbulent flow, an anisotropic algebraic stress model is adopted to predict the turbulent flow field and turbulent characteristics generated by a Rushton disc turbine with the improved inner-outer iterative procedure. The predicted turbulent flow is compared with experimental data and the simulation by the standard κ-ε turbulence model. The anisotropic algebraic stress model is found to give better prediction than the standard κ-ε turbulence model. The predicted turbulent flow field is in accordance to experimental data and the trend of the turbulence intensity can be effectively reflected in the simulation. The distribution of turbulent shear rate in the stirred tanks was simulated with the established numerical procedure.

  1. The Model of Thermal Response of Liquefied Petroleum Gas Tanks Partially Exposed to Jet Fire%液化石油气储罐在喷射火焰作用下的热响应模型

    Institute of Scientific and Technical Information of China (English)

    邢志祥; 蒋军成; 赵晓芳

    2004-01-01

    This paper describes a mathematical model developed to study the behavior of liquefied petroleum gas (LPG) tanks when subjected to jet fire. The model consists of a number of field and zone sub-models which are used to simulate the various physical phenomena taking place during the tank engulfment period. The model can be used to predict the pressure and temperature of the LPG in the tank, the temperature of the wall of tank, and the time of tank explosion. The comparisons between the model predicted results and the test data show good agreement. The results show that the jet fire partially impinging on tank wall led to higher wall temperature and the time to failure was shorter than that in engulfing pool fire. And the exposure of the upper wall in the vapor zone to the fire is more dangerous than that of the LPG contacted wall.

  2. Hanford waste tank cone penetrometer

    Energy Technology Data Exchange (ETDEWEB)

    Seda, R.Y.

    1995-12-01

    A new tool is being developed to characterize tank waste at the Hanford Reservation. This tool, known as the cone penetrometer, is capable of obtaining chemical and physical properties in situ. For the past 50 years, this tool has been used extensively in soil applications and now has been modified for usage in Hanford Underground Storage tanks. These modifications include development of new ``waste`` data models as well as hardware design changes to accommodate the hazardous and radioactive environment of the tanks. The modified cone penetrometer is scheduled to be deployed at Hanford by Fall 1996. At Hanford, the cone penetrometer will be used as an instrumented pipe which measures chemical and physical properties as it pushes through tank waste. Physical data, such as tank waste stratification and mechanical properties, is obtained through three sensors measuring tip pressure, sleeve friction and pore pressure. Chemical data, such as chemical speciation, is measured using a Raman spectroscopy sensor. The sensor package contains other instrumentation as well, including a tip and side temperature sensor, tank bottom detection and an inclinometer. Once the cone penetrometer has reached the bottom of the tank, a moisture probe will be inserted into the pipe. This probe is used to measure waste moisture content, water level, waste surface moisture and tank temperature. This paper discusses the development of this new measurement system. Data from the cone penetrometer will aid in the selection of sampling tools, waste tank retrieval process, and addressing various tank safety issues. This paper will explore various waste models as well as the challenges associated with tank environment.

  3. Research advances and challenges in one-dimensional modeling of secondary settling tanks--a critical review.

    Science.gov (United States)

    Li, Ben; Stenstrom, M K

    2014-11-15

    Sedimentation is one of the most important processes that determine the performance of the activated sludge process (ASP), and secondary settling tanks (SSTs) have been frequently investigated with the mathematical models for design and operation optimization. Nevertheless their performance is often far from satisfactory. The starting point of this paper is a review of the development of settling theory, focusing on batch settling and the development of flux theory, since they played an important role in the early stage of SST investigation. The second part is an explicit review of the established 1-D SST models, including the relevant physical law, various settling behaviors (hindered, transient, and compression settling), the constitutive functions, and their advantages and disadvantages. The third part is a discussion of numerical techniques required to solve the governing equation, which is usually a partial differential equation. Finally, the most important modeling challenges, such as settleability description, settling behavior understanding, are presented.

  4. APLIKASI TANK MODEL DAN KESEIMBANGAN NERACA AIR STUDI KASUS MODEL DAS MIKRO (MDM,SUB-DAS CISAMPORA, DAS CIMANUK, KABUPATEN MAJALENGKA PROVINSI JAWA BARAT

    Directory of Open Access Journals (Sweden)

    Syampadzi Nurroh dan Nana Mulyana Arifjaya

    2015-11-01

    Full Text Available The influence of forest cover in landuse is an important concern in the goverment’s regulation for distributionof water flow into the rivers. The River flow is one of the hydrology paramater importantness in order to bepriority in managamenet environmental. The one of hydrology which could be used for water balancepredictionbyTank Model. The Tank Model was applied using daily rainfall, evapotranspiration, and discharge river. Basedon research results that water balance are calculated by input parameter (precipitation, 678 mm with outputparameter by discharge (623,48 mm inequation curve discharge(Q = 1,606 (TMA1, 494 with the correlation (R2is 0,993and evapotranspiration (631,04 mm. Based on the indicators of the reliability of the Tank model thatthe value of the correlation coefficient (R of 0,84 can be presented the results of verification in this case quitesatisfactory. The water balancewas surplus ouput by calculated 550 mm of water storage in ground water (38,80%,outflowdistributed recharge river 622,21 mm(33,90% regard to runoff including 24% (runoff coefficient 0,24and evapotranspiration 504,8 mm (27,30%.

  5. The Continued Need for Modeling and Scaled Testing to Advance the Hanford Tank Waste Mission

    Energy Technology Data Exchange (ETDEWEB)

    Peurrung, Loni M.; Fort, James A.; Rector, David R.

    2013-09-03

    Hanford tank wastes are chemically complex slurries of liquids and solids that can exhibit changes in rheological behavior during retrieval and processing. The Hanford Waste Treatment and Immobilization Plant (WTP) recently abandoned its planned approach to use computational fluid dynamics (CFD) supported by testing at less than full scale to verify the design of vessels that process these wastes within the plant. The commercial CFD tool selected was deemed too difficult to validate to the degree necessary for use in the design of a nuclear facility. Alternative, but somewhat immature, CFD tools are available that can simulate multiphase flow of non-Newtonian fluids. Yet both CFD and scaled testing can play an important role in advancing the Hanford tank waste mission—in supporting the new verification approach, which is to conduct testing in actual plant vessels; in supporting waste feed delivery, where scaled testing is ongoing; as a fallback approach to design verification if the Full Scale Vessel Testing Program is deemed too costly and time-consuming; to troubleshoot problems during commissioning and operation of the plant; and to evaluate the effects of any proposed changes in operating conditions in the future to optimize plant performance.

  6. Molecular weight​/branching distribution modeling of low-​density-​polyethylene accounting for topological scission and combination termination in continuous stirred tank reactor

    NARCIS (Netherlands)

    Yaghini, N.; Iedema, P.D.

    2014-01-01

    We present a comprehensive model to predict the molecular weight distribution (MWD),(1) and branching distribution of low-density polyethylene (IdPE),(2) for free radical polymerization system in a continuous stirred tank reactor (CSTR).(3) The model accounts for branching, by branching moment or ps

  7. Modeling validation to structural flaws in the foundations of oil tanks; Validacao de modelagem para estudo de alteracoes estruturais em fundacoes de tanques de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Couto, Larissa Goncalves; Leite, Sandro Passos, E-mail: leite_sp@ig.com.br [Fundacao Tecnico-Educacional Souza Marques, Rio de Janeiro, RJ (Brazil). Faculdade de Engenharia; Pereira, Walsan Wagner [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    This paper presents the modeling of an experiment used to study the application of backscattered neutrons in the identification of structural flaws in the foundations of oil tanks. This modeling was a preliminary validation procedure of the method of calculation, performed with the radiation transport code MCNP, to study the application of backscattered neutrons as inspection tool. (author)

  8. Dual mode adaptive fractional order PI controller with feedforward controller based on variable parameter model for quadruple tank process.

    Science.gov (United States)

    Roy, Prasanta; Roy, Binoy Krishna

    2016-07-01

    The Quadruple Tank Process (QTP) is a well-known benchmark of a nonlinear coupled complex MIMO process having both minimum and nonminimum phase characteristics. This paper presents a novel self tuning type Dual Mode Adaptive Fractional Order PI controller along with an Adaptive Feedforward controller for the QTP. The controllers are designed based on a novel Variable Parameter Transfer Function model. The effectiveness of the proposed model and controllers is tested through numerical simulation and experimentation. Results reveal that the proposed controllers work successfully to track the reference signals in all ranges of output. A brief comparison with some of the earlier reported similar works is presented to show that the proposed control scheme has some advantages and better performances than several other similar works.

  9. Feed tank transfer requirements

    Energy Technology Data Exchange (ETDEWEB)

    Freeman-Pollard, J.R.

    1998-09-16

    This document presents a definition of tank turnover. Also, DOE and PC responsibilities; TWRS DST permitting requirements; TWRS Authorization Basis (AB) requirements; TWRS AP Tank Farm operational requirements; unreviewed safety question (USQ) requirements are presented for two cases (i.e., tank modifications occurring before tank turnover and tank modification occurring after tank turnover). Finally, records and reporting requirements, and documentation which will require revision in support of transferring a DST in AP Tank Farm to a privatization contractor are presented.

  10. Inerting ballast tanks

    Energy Technology Data Exchange (ETDEWEB)

    Baes, Gabriel L.; Bronneberg, Jos [SBM Offshore, AA Schiedam (Netherlands); Barros, Maria A.S.D. de [Universidade Estadual de Maringa (UEM), PR (Brazil)

    2012-07-01

    This report expands upon the work conducted by SBM Offshore to develop a tank preservation treatment, which is intended to achieve a service life of 30 years. This work focuses on the corrosion problems, in the ballast tanks, based on new built hulls, both for the Gas Exploration Market, the FLNG - Floating Liquefied Natural Gas, and for the Oil Exploration market - FPSO's - Floating Production Storage and offloading Units. Herein, the corrosion rate input comes from the various references related to the process of nitrogen injection, which is expected to extend the vessel's time life. The essential elements of this solution comprise the deoxygenation process, corrosion models, coating effects, tests from laboratory, shipboard tests, corrosion institutes and regulations applicable to the operation. The best corrosion protection system for ballast tanks area combines a coating system and an inert gas system. The condition of the tanks will be dependent upon the level of protection applied to the steel structure, including, but not limited to coating, cathodic protection, etc. There is a need for products which extend the life time. It is not sufficient, only have good theoretical base for the corrosion and an excellent treatment system. In addition, the design of the ships structure must also eliminate the presence of local stress concentrations which can result in fatigue cracking and rupture of the protective coating barrier starting the corrosion. As a direct result of this, more problems in corrosion can be mitigated, vessels can have a better corrosion performance with less maintenance and repairs to coating systems in ballast tanks. Furthermore ships will be positively impacted operationally due to less frequent dry docking. There is a huge potential in the application of inert gas to combat the corrosion rate inside the ballast tanks, one of the most corrosive environments on earth. This application can have a direct impact on vessel structure

  11. The model of back-flow mixed tanks-in-series used for representing the liquid flow in a reciprocating plate column

    Directory of Open Access Journals (Sweden)

    Nikolić Ljubiša B.

    2003-01-01

    Full Text Available The influence of different working parameters (vibration intensity superficial gas and liquid rate and content of the solid phase on liquid flow in a multiphase (gas-liquid: RPC-II and gas-liquid-solid: RPC-III reciprocating plate column was analyzed using step-response methods and sorbic acid as a tracer. The liquid flow was determined using a model of N-tanks in series followed by back mixing of the liquid phase between the tanks. The parameters of this model N, a and x were calculated by applying several methods: calculation of the moments of the residence time distribution function for a constant number of tanks in series (N=const analysis of a set of linear equations for N *const and determination of the minimum of defined goal function using the optimization technique leastsq.m of MATLAB software.

  12. Analysis of flashing and swelling phenomena in tanks of nuclear power plants; the importance of bubble growth dynamics and bubble transport models with size tracking

    Energy Technology Data Exchange (ETDEWEB)

    Cerezo A, E. [University of Caribe, Department of Basics Sciences and Engineering, Lote 1, Manzana 1, Region 78, esq. Fracc. Tabachines, 77500 Cancun, Quintana Roo (Mexico)]. E-mail: ecerezo@unicaribe.edu.mx; Munoz C, J.L. [Department of Chemical and Nuclear Engineering, Polytechnic University of Valencia, Camino de Vera 14, 46022 Valencia (Spain)

    2004-07-01

    This paper presents a non-equilibrium model to describe flashing phenomena in tanks and cooling pools. The present model is based on Watanabe's work that we have extended by developing a realistic model for the growth of bubbles. We have made the corresponding venting model, continuity equation, gas and liquid phase energy conservation equations for the model. This model takes into account both drag and virtual mass force. The dynamics of bubble growth plays an important role in two-phase phenomena such as flashing. In our model the growth rate is assumed to be limited by the heat conduction in the liquid. The results of the analytic model were compared with the experimental data of Watanabe [1]. The results have shown that the present model evaluates fairly accurately the pressure evolution, the void fraction and the swelling level of a tank.

  13. 49 CFR 172.331 - Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. 172.331 Section 172.331 Transportation Other Regulations... packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. (a) Each...

  14. A collection of the collapsed results of general tank tests of miscellaneous flying-boat-hull models

    Science.gov (United States)

    Locke, F W S , Jr

    1947-01-01

    Presented here are the summary charts of the collapsed results of general tank tests of about 100 flying boat hull models. These summary charts are intended to be used as an engineering tool to enable a flying boat designer to grasp more quickly the significance of various hull form parameters as they influence his particular airplane. The form in which the charts are prepared is discussed in some detail in order to make them clearer to the designer. This is a data report, and no attempt has been made to produce conclusions or correlations of the usual sort. However, some generalizations are put forward on the various methods in which summary charts may be used.

  15. ICPP Tank Farm planning through 2012

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, W.B.; Millet, C.B.; Staiger, M.D.; Ward, F.S.

    1998-04-01

    Historically, liquid high-level waste (HLW) generated at the Idaho Chemical Processing Plant has been stored in the Tank Farm after which it is calcined with the calcine being stored in stainless steel bins. Following the curtailment of spent nuclear fuel reprocessing in 1992, the HLW treatment methods were re-evaluated to establish a path forward for producing a final waste form from the liquid sodium bearing wastes (SBW) and the HLW calcine. Projections for significant improvements in waste generation, waste blending and evaporation, and calcination were incorporated into the Tank Farm modeling. This optimized modeling shows that all of the SBW can be calcined by the end of 2012 as required by the Idaho Settlement Agreement. This Tank Farm plan discusses the use of each of the eleven HLW tanks and shows that two tanks can be emptied, allowing them to be Resource Conservation and Recovery Act closed by 2006. In addition, it describes the construction of each tank and vault, gives the chemical concentrations of the contents of each tank, based on historical input and some sampling, and discusses the regulatory drivers important to Tank Farm operation. It also discusses new waste generation, the computer model used for the Tank Farm planning, the operating schedule for each tank, and the schedule for when each tank will be empty and closed.

  16. Modelling of a solid oxide fuel cell CHP system coupled with a hot water storage tank for a single household

    DEFF Research Database (Denmark)

    Liso, Vincenzo; Zhao, Yingru; Yang, Wenyuan

    2015-01-01

    In this paper a solid oxide fuel cell (SOFC) system for cogeneration of heat and power integrated with a stratified heat storage tank is studied. The use of a storage tank with thermal stratification allows one to increase the annual operating hours of CHP: heat can be produced when the request...

  17. 75 FR 71346 - Special Conditions: Boeing Model 787-8 Airplane; Lightning Protection of Fuel Tank Structure To...

    Science.gov (United States)

    2010-11-23

    ... flammability significantly below the maximum wing fuel tank flammability limits set in Sec. 25.981(b), as.... 25.981(a), as amended by Amendment 25-102, and it includes revised flammability limits for the wing... failures. Flammability Limits Section 25.981(b) states that no fuel tank fleet average...

  18. AX Tank Farm tank removal study

    Energy Technology Data Exchange (ETDEWEB)

    SKELLY, W.A.

    1999-02-24

    This report examines the feasibility of remediating ancillary equipment associated with the 241-AX Tank Farm at the Hanford Site. Ancillary equipment includes surface structures and equipment, process waste piping, ventilation components, wells, and pits, boxes, sumps, and tanks used to make waste transfers to/from the AX tanks and adjoining tank farms. Two remedial alternatives are considered: (1) excavation and removal of all ancillary equipment items, and (2) in-situ stabilization by grout filling, the 241-AX Tank Farm is being employed as a strawman in engineering studies evaluating clean and landfill closure options for Hanford single-shell tanks. This is one of several reports being prepared for use by the Hanford Tanks Initiative Project to explore potential closure options and to develop retrieval performance evaluation criteria for tank farms.

  19. Modeling Droplet Heat and Mass Transfer during Spray Bar Pressure Control of the Multipurpose Hydrogen Test Bed (MHTB) Tank in Normal Gravity

    Science.gov (United States)

    Kartuzova, O.; Kassemi, M.

    2016-01-01

    A CFD model for simulating pressure control in cryogenic storage tanks through the injection of a subcooled liquid into the ullage is presented and applied to the 1g MHTB spray bar cooling experiments. An Eulerian-Lagrangian approach is utilized to track the spray droplets and capture the interaction between the discrete droplets and the continuous ullage phase. The spray model is coupled with the VOF model by performing particle tracking in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. A new model for calculating the droplet-ullage heat and mass transfer is developed. In this model, a droplet is allowed to warm up to the saturation temperature corresponding to the ullage vapor pressure, after which it evaporates while remaining at the saturation temperature. The droplet model is validated against the results of the MHTB spray-bar cooling experiments with 50% and 90% tank fill ratios. The predictions of the present T-sat based model are compared with those of a previously developed kinetic-based droplet mass transfer model. The predictions of the two models regarding the evolving tank pressure and temperature distributions, as well as the droplets' trajectories and temperatures, are examined and compared in detail. Finally, the ullage pressure and local vapor and liquid temperature evolutions are validated against the corresponding data provided by the MHTB spray bar mixing experiment.

  20. Influence of selecting secondary settling tank sub-models on the calibration of WWTP models – A global sensitivity analysis using BSM2

    DEFF Research Database (Denmark)

    Ramin, Elham; Flores Alsina, Xavier; Sin, Gürkan;

    2014-01-01

    This study investigates the sensitivity of wastewater treatment plant (WWTP) model performance to the selection of one-dimensional secondary settling tanks (1-D SST) models with first-order and second-order mathematical structures. We performed a global sensitivity analysis (GSA) on the benchmark......, the settling parameters were found to be as influential as the biokinetic parameters on the uncertainty of WWTP model predictions, particularly for biogas production and treated water quality. However, the sensitivity measures were found to be dependent on the 1-D SST models selected. Accordingly, we suggest...... have, however, no physical meaning, and might additionally obtain unrealistic values. In contrast, using second-order SST models, the focus of calibration should be on providing measured values for the hindered settling parameters. This approach is in close agreement with the recommendations made...

  1. Pad B Liquid Hydrogen Storage Tank

    Science.gov (United States)

    Hall, Felicia

    2007-01-01

    Kennedy Space Center is home to two liquid hydrogen storage tanks, one at each launch pad of Launch Complex 39. The liquid hydrogen storage tank at Launch Pad B has a significantly higher boil off rate that the liquid hydrogen storage tank at Launch Pad A. This research looks at various calculations concerning the at Launch Pad B in an attempt to develop a solution to the excess boil off rate. We will look at Perlite levels inside the tank, Boil off rates, conductive heat transfer, and radiant heat transfer through the tank. As a conclusion to the research, we will model the effects of placing an external insulation to the tank in order to reduce the boil off rate and increase the economic efficiency of the liquid hydrogen storage tanks.

  2. Tank 241-BX-106: Tank characterization plan

    Energy Technology Data Exchange (ETDEWEB)

    Schreiber, R.D.

    1995-03-06

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, and WHC 222-S Laboratory. Scope of this plan is to provide guidance for sampling and analysis of samples for tank 241-BX-106. (Waste from this tank shall be transferred to a double-shell tank.)

  3. Material Modeling of Space Shuttle Leading Edge and External Tank Materials For Use in the Columbia Accident Investigation

    Science.gov (United States)

    Carney, Kelly; Melis, Matthew; Fasanella, Edwin L.; Lyle, Karen H.; Gabrys, Jonathan

    2004-01-01

    Upon the commencement of the analytical effort to characterize the impact dynamics and damage of the Space Shuttle Columbia leading edge due to External Tank insulating foam, the necessity of creating analytical descriptions of these materials became evident. To that end, material models were developed of the leading edge thermal protection system, Reinforced Carbon Carbon (RCC), and a low density polyurethane foam, BX-250. Challenges in modeling the RCC include its extreme brittleness, the differing behavior in compression and tension, and the anisotropic fabric layup. These effects were successfully included in LS-DYNA Material Model 58, *MAT_LAMINATED_ COMPOSITE_ FABRIC. The differing compression and tension behavior was modeled using the available damage parameters. Each fabric layer was given an integration point in the shell element, and was allowed to fail independently. Comparisons were made to static test data and coupon ballistic impact tests before being utilized in the full scale analysis. The foam's properties were typical of elastic automotive foams; and LS-DYNA Material Model 83, *MAT_FU_CHANG_FOAM, was successfully used to model its behavior. Material parameters defined included strain rate dependent stress-strain curves for both loading and un-loading, and for both compression and tension. This model was formulated with static test data and strain rate dependent test data, and was compared to ballistic impact tests on load-cell instrumented aluminum plates. These models were subsequently utilized in analysis of the Shuttle leading edge full scale ballistic impact tests, and are currently being used in the Return to Flight Space Shuttle re-certification effort.

  4. Modeling of the Radiation Doses during Dismantling of RBMK-1500 Reactor Pressurized Tanks from Emergency Core Cooling System

    Directory of Open Access Journals (Sweden)

    A. Simonis

    2013-01-01

    Full Text Available Decommissioning of the Ignalina Nuclear Power Plant involves multiple problems. One of them is personnel radiation safety during the performance of dismantling activities. In this paper, modeling results of radiation doses during the dismantling of the pressurized tank from the emergency core cooling system (ECCS PT of RBMK-1500 reactor are presented. The radiological surveys indicate that the inner surface of the ECCS PT is contaminated with radioactive products of corrosion and sediments due to the radioactive water. The effective doses to the workers have been modeled for different strategies of ECCS PT dismantling. In order to select the optimal personnel radiation safety, the modeling has been performed by the means of computer code “VISIPLAN 3D ALARA Planning tool” developed by SCK CEN (Belgium. The impacts of dismantling tools, shielding types, and extract ventilation flow rate on effective doses during the dismantling of ECCS PT have been analyzed. The total effective personnel doses have been obtained by summarizing the effective personnel doses from various sources of exposure, that is, direct radiation from radioactive equipment, internal radiation due to inhalation of radioactive aerosols, and direct radiation from radioactive aerosols arising during hot cutting in premises. The uncertainty of the collective doses is also presented in this paper.

  5. Numerical modelling of disintegration of basin-scale internal waves in a tank filled with stratified water

    Directory of Open Access Journals (Sweden)

    N. Stashchuk

    2005-01-01

    Full Text Available We present the results of numerical experiments performed with the use of a fully non-linear non-hydrostatic numerical model to study the baroclinic response of a long narrow tank filled with stratified water to an initially tilted interface. Upon release, the system starts to oscillate with an eigen frequency corresponding to basin-scale baroclinic gravitational seiches. Field observations suggest that the disintegration of basin-scale internal waves into packets of solitary waves, shear instabilities, billows and spots of mixed water are important mechanisms for the transfer of energy within stratified lakes. Laboratory experiments performed by D. A. Horn, J. Imberger and G. N. Ivey (JFM, 2001 reproduced several regimes, which include damped linear waves and solitary waves. The generation of billows and shear instabilities induced by the basin-scale wave was, however, not sufficiently studied. The developed numerical model computes a variety of flows, which were not observed with the experimental set-up. In particular, the model results showed that under conditions of low dissipation, the regimes of billows and supercritical flows may transform into a solitary wave regime. The obtained results can help in the interpretation of numerous observations of mixing processes in real lakes.

  6. Tank Tests of a Model of One Hull of the Savoia S-55-X Flying Boat N.A.C.A. Model 46

    Science.gov (United States)

    Allison, John M

    1938-01-01

    A model of one of the twin hulls of the Italian Savoia S-55-X flying boat (N.A.C.A. Model 46) was tested in the N.A.C.A. tank according to the general method. The data obtained from these tests cover a broad range of speeds, loads, and trims and are given in nondimensional form to facilitate their use in applying this form of hull to any other flying boat or comparing it's performance with the performance of any other hulls. The results show that the resistance characteristics at best trim of this model are excellent throughout the speed range. In order to compare the performance of the S-55-X hull with that of the 35, a pointed-step hull developed at the N.A.C.A. tank, the data are used in the computations of take-off example of a twin-hull, 23,500-pound flying boat. The calculations show that the S-55-X hull has better take-off performance.

  7. 49 CFR 172.330 - Tank cars and multi-unit tank car tanks.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Tank cars and multi-unit tank car tanks. 172.330..., TRAINING REQUIREMENTS, AND SECURITY PLANS Marking § 172.330 Tank cars and multi-unit tank car tanks. (a... material— (1) In a tank car unless the following conditions are met: (i) The tank car must be marked...

  8. Tanks Test of a Model of the Hull of the Navy PB-1 Flying Boat - N.A.C.A. Model 52

    Science.gov (United States)

    Allison, John M

    1936-01-01

    A model of the hull of the Navy PB-1 flying boat was tested in the N.A.C.A. tank as part of a program intended to provide information regarding the water performance of hulls of flying boats of earlier design for which hydrodynamic data have heretofore been unavailable. Tests were made according to the general method over the range of practical loadings with the model both fixed in trim and free to trim. A free-to-trim test according to the specific method was also made for the design load and take-off speed corresponding to those of the full-scale flying boat. The resistance obtained from the fixed-trim test was found to be about the same as that of the model of the NC flying-boat hull, and greater at the hump but smaller at high speeds than that of a model of the Sikorsky S-40 flying-boat hull.

  9. Tank tests of a model of a flying-boat hull with a fluted bottom

    Science.gov (United States)

    Dawson, John R

    1935-01-01

    A 1/5-scale model of a flying-boat hull having flutes in the bottom both forward and aft of the step (NACA model 19) was tested to determine its water performance. The model was also tested after the successive removal of the flutes on the afterbody and forebody. The results from these tests are compared with those from tests of a model of the hull of the Navy PN-8 flying boat and it is concluded that the fluted-bottom model and its modifications are inferior to the model of the PN-8.

  10. Historical Tank Content Estimate for the Northwest Quandrant of the Hanford 200 East Area

    Energy Technology Data Exchange (ETDEWEB)

    Brevick, C.H.; Gaddis, L.A.; Pickett, W.W.

    1994-06-01

    Historical Tank Content Estimate of the Northeast Quadrant provides historical evaluations on a tank by tank basis of the radioactive mixed wastes stored in the underground single-shell tanks of the Hanford 200 East area. This report summaries historical information such at waste history, temperature, tank integrity, inventory estimates and tank level history on a tank by tank basis. Tank Farm aerial photos and in-tank photos of each tank are provided. A brief description of instrumentation methods used for waste tank surveillance, along with the components of the data management effort, such as waste status and Transaction Record Summary, Tank Layering Model, Defined Waste Types, and Inventory Estimates to generate these tank content estimates are also given in this report.

  11. AX Tank Farm tank removal study

    Energy Technology Data Exchange (ETDEWEB)

    SKELLY, W.A.

    1998-10-14

    This report considers the feasibility of exposing, demolishing, and removing underground storage tanks from the 241-AX Tank Farm at the Hanford Site. For the study, it was assumed that the tanks would each contain 360 ft{sup 3} of residual waste (corresponding to the one percent residual Inventory target cited in the Tri-Party Agreement) at the time of demolition. The 241-AX Tank Farm is being employed as a ''strawman'' in engineering studies evaluating clean and landfill closure options for Hanford single-shell tank farms. The report is one of several reports being prepared for use by the Hanford Tanks Initiative Project to explore potential closure options and to develop retrieval performance evaluation criteria for tank farms.

  12. AX Tank Farm tank removal study

    Energy Technology Data Exchange (ETDEWEB)

    SKELLY, W.A.

    1998-10-14

    This report considers the feasibility of exposing, demolishing, and removing underground storage tanks from the 241-AX Tank Farm at the Hanford Site. For the study, it was assumed that the tanks would each contain 360 ft{sup 3} of residual waste (corresponding to the one percent residual Inventory target cited in the Tri-Party Agreement) at the time of demolition. The 241-AX Tank Farm is being employed as a ''strawman'' in engineering studies evaluating clean and landfill closure options for Hanford single-shell tank farms. The report is one of several reports being prepared for use by the Hanford Tanks Initiative Project to explore potential closure options and to develop retrieval performance evaluation criteria for tank farms.

  13. Tank Model Application for Runoff and Infiltration Analysis on Sub-Watersheds in Lalindu River in South East Sulawesi Indonesia

    Science.gov (United States)

    Wirdhana Ahmad, Sitti

    2017-05-01

    Improper land management often causes flood, this is due to uncontrolled runoff. Runoff is affected by the management of the land cover. The phenomena also occurred in South East Sulawesi, Indonesia. This study aims to analyze the flow rate of water in watershed of Lalindu River in North Konawe, South East Sulawesi by using a Tank Model. The model determined the magnitude of the hydrologic runoff, infiltration capacity and soil water content several land uses were evaluated in the study area. The experimental and calculation results show that the runoff in the forest is 2,639.21 mm/year, in the reed is 2,517.05 mm/year, in the oil palm with a slope more than 45% is 2,715.36 mm/year, and in the oil palm with slopes less than 45% is 2,709.59 mm/year. Infiltration in the forest is 30.70 mm/year, in the reed is 7.51 mm/year, in the palm oil with a slope more than 45% is 24.13 mm/year and in the palm oil with slopes less than 45% is 29.67 mm/year. Runoff contributes to stream flow for water availability.

  14. The implementation of biofiltration systems, rainwater tanks and urban irrigation in a single-layer urban canopy model

    Science.gov (United States)

    Demuzere, Matthias; Coutts, Andrew; Goehler, Maren; Broadbent, Ashley; Wouters, Hendrik; van Lipzig, Nicole; Gebert, Luke

    2015-04-01

    Urban vegetation is generally considered as a key tool to modify the urban energy balance through enhanced evapotranspiration (ET). Given that vegetation is most effective when it is healthy, stormwater harvesting and retention strategies (such as water sensitive urban design) could be used to support vegetation and promote ET. This study presents the implementation of a vegetated lined bio-filtration system (BFS) combined with a rainwater tank (RWT) and urban irrigation system in the single-layer urban canopy model Community Land Model-Urban. Runoff from roof and impervious road surface fractions is harvested and used to support an adequate soil moisture level for vegetation in the BFS. In a first stage, modelled soil moisture dynamics are evaluated and found reliable compared to observed soil moisture levels from biofiltration pits in Smith Street, Melbourne (Australia). Secondly, the impact of BFS, RWT and urban irrigation on ET is illustrated for a two-month period in 2012 using varying characteristics for all components. Results indicate that (i) a large amount of stormwater is potentially available for indoor and outdoor water demands, including irrigation of urban vegetation, (ii) ET from the BFS is an order of magnitude larger compared to the contributions from the impervious surfaces, even though the former only covers 10% of the surface fraction and (iii) attention should be paid to the cover fraction and soil texture of the BFS, size of the RWT and the surface fractions contributing to the collection of water in the RWT. Overall, this study reveals that this model development can effectuate future research with state-of-the-art urban climate models to further explore the benefits of vegetated biofiltration systems as a water sensitive urban design tool optimised with an urban irrigation system to maintain healthy vegetation.

  15. HANFORD TANK CLEANUP UPDATE

    Energy Technology Data Exchange (ETDEWEB)

    BERRIOCHOA MV

    2011-04-07

    Access to Hanford's single-shell radioactive waste storage tank C-107 was significantly improved when workers completed the cut of a 55-inch diameter hole in the top of the tank. The core and its associated cutting equipment were removed from the tank and encased in a plastic sleeve to prevent any potential spread of contamination. The larger tank opening allows use of a new more efficient robotic arm to complete tank retrieval.

  16. Dynamic optimization and robust explicit model predictive control of hydrogen storage tank

    KAUST Repository

    Panos, C.

    2010-09-01

    We present a general framework for the optimal design and control of a metal-hydride bed under hydrogen desorption operation. The framework features: (i) a detailed two-dimension dynamic process model, (ii) a design and operational dynamic optimization step, and (iii) an explicit/multi-parametric model predictive controller design step. For the controller design, a reduced order approximate model is obtained, based on which nominal and robust multi-parametric controllers are designed. © 2010 Elsevier Ltd.

  17. Design of nonlinear PID controller and nonlinear model predictive controller for a continuous stirred tank reactor.

    Science.gov (United States)

    Prakash, J; Srinivasan, K

    2009-07-01

    In this paper, the authors have represented the nonlinear system as a family of local linear state space models, local PID controllers have been designed on the basis of linear models, and the weighted sum of the output from the local PID controllers (Nonlinear PID controller) has been used to control the nonlinear process. Further, Nonlinear Model Predictive Controller using the family of local linear state space models (F-NMPC) has been developed. The effectiveness of the proposed control schemes has been demonstrated on a CSTR process, which exhibits dynamic nonlinearity.

  18. Implementasi Metode Optimasi Particle Swarm Optimization (PSO untuk Tuning Pengendali Model Predictive Control (MPC pada Quadruple Tank

    Directory of Open Access Journals (Sweden)

    Kamal Fu'ad

    2013-09-01

    Full Text Available Pada penelitian ini telah dibangun mode kontrol Model Predictive Control (MPC dengan metode optimasi Particle Swarm Optimization untuk mencari nilai terbaik pada parameter beban sinyal kontrol Wu dan sinyal control error W∆u yang kemudian diimplementasikan secara online pada rancang bangun system Quadruple Tank. Metode IMOPSO untuk MPC dengan nilai sinyal control Wu =0.0076 dan sinyal control error Wdu = 0.1221 menghasilkan respon system terbaik dengan maximum overshoot = 4% error steady state 1% settling time 55 detik dibandingkan MOPSO dengan nilai sinyal control Wu 0.0397 dan sinyal control error Wdu 0.1780 menghasilkan respon sistem dengan maksimum overshoot = 5% Error Steady State = 3 % settling time 65 detik. Selain itu, dibangun juga control PSO – PID yang digunakan sebagai pembanding dimana mode MOPSO menghasilkan nilai Kp = 3.0828 Ki = 0.4219 memiliki respon sistem dengan maksimum overshoot = 3 % Error Steady State = 2% dan settling time 250 detik. Sedangkan pada mode IMOPS nilai Kp = 2.9388 Ki = 0.2166 memiliki respon system dengan maksimum overshoot = 3 % Error Steady State 1.5% dan settling time 150 detik.

  19. 基于MLD模型的CSTR建模和控制%Modeling and Control of a Continuous Stirred Tank Reactor Based on a Mixed Logical Dynamical Model

    Institute of Scientific and Technical Information of China (English)

    杜静静; 宋春跃; 李平

    2007-01-01

    A novel control strategy for a continuous stirred tank reactor (CSTR) system, which has the typical characteristic of strongly pronounced nonlinearity, multiple operating points, and a wide operating range, is initiated from the point of hybrid systems. The proposed scheme makes full use of the modeling power of mixed logical dynamical (MLD) systems to describe the highly nonlinear dynamics and multiple operating points in a unified framework as a hybrid system, and takes advantage of the good control quality of model predictive control (MPC)to design a controller. Thus, this approach avoids oscillation during switching between sub-systems, helps to relieve shaking in transition, and augments the stability robustness of the whole system, and finally achieves optimal (i.e.fast and smooth) transition between operating points. The simulation results demonstrate that the presented approach has a satisfactory performance.

  20. Computational Fluid Dynamics Modelling of Hydraulics and Sedimentation in Process Reactors During Aeration Tank Settling

    DEFF Research Database (Denmark)

    Dam Jensen, Mette; Ingildsen, Pernille; Rasmussen, Michael R.;

    2005-01-01

    shown to be more effective than others. To improve the design of less effective plants Computational Fluid Dynamics (CFD) modelling of hydraulics and sedimentation has been applied. The paper discusses the results at one particular plant experiencing problems with partly short-circuiting of the inlet...... been suggested and tested by means of computational fluid dynamics modelling. The most promissing design change have been found and reported....

  1. A Mathematical model for ethanol production by extractive fermentation in a continuous stirred tank fermentor.

    Science.gov (United States)

    Kollerup, F; Daugulis, A J

    1985-09-01

    Extractive fermentation is a technique that can be used to reduce the effect of end product inhibition through the use of a water-immiscible phase that removes fermentation products in situ. This has the beneficial effect of not only removing inhibitory products as they are formed (thus keeping reaction rates high) but also has the potential for reducing product recovery costs. We have chosen to examine the ethanol fermentation as a model system for end product inhibition and extractive fermentation and have developed a computer model predicting the productivity enhancement possible with this technique together with other key parameters such as extraction efficiency and residual glucose concentration. The model accommodates variable liquid flowrates entering and leaving the system, since it was found that the aqueous outlet flowrate could be up to 35% lower than the inlet flowrate during extractive fermentation of concentrated glucose feeds due to the continuous removal of ethanol from the fermentation broth by solvent extraction. The model predicts a total ethanol productivity of 82.6 g/L h if a glucose feed of 750 g/L is fermented with a solvent having a distribution coefficient of 0.5 at a solvent dilution rate of 5.0 h(-1). This is more than 10 times higher than for a conventional chemostat fermentation of a 250 g/L glucose feed. The model has furthermore illustrated the possible trade-offs that exist between obtaining a high extraction efficiency and a low residual glucose concentration.

  2. Physical Properties Models for Simulation of Processes to Treat INEEL Tank Farm Waste: Thermodynamic Equilibrium

    Energy Technology Data Exchange (ETDEWEB)

    Nichols, T.T.; Taylor, D.D.

    2002-07-18

    A status is presented of the development during FY2002 of a database for physical properties models for the simulation of the treatment of Sodium-Bearing Waste (SBW) at the Idaho National Engineering and Environmental Laboratory. An activity coefficient model is needed for concentrated, aqueous, multi-electrolyte solutions that can be used by process design practitioners. Reasonable first-order estimates of activity coefficients in the relevant media are needed rather than an incremental improvement in theoretical approaches which are not usable by practitioners. A comparison of the Electrolyte Non-Random Two-Liquid (ENRTL) and Pitzer ion-interaction models for the thermodynamic representation of SBW is presented. It is concluded that Pitzer's model is superior to ENRTL in modeling treatment processes for SBW. The applicability of the Pitzer treatment to high concentrations of pertinent species and to the determination of solubilities and chemical equilibria is addressed. Alternate values of Pitzer parameters for HCl, H2SO4, and HNO3 are proposed, applicable up to 16m, and 12m, respectively. Partial validation of the implementation of Pitzer's treatment within the commercial process simulator ASPEN Plus was performed.

  3. Physical Properties Models for Simulation of Processes to Treat INEEL Tank Farm Waste: Thermodynamic Equilibrium

    Energy Technology Data Exchange (ETDEWEB)

    Nichols, Todd Travis; Taylor, Dean Dalton

    2002-07-01

    A status is presented of the development during FY2002 of a database for physical properties models for the simulation of the treatment of Sodium-Bearing Waste (SBW) at the Idaho National Engineering and Environmental Laboratory. An activity coefficient model is needed for concentrated, aqueous, multi-electrolyte solutions that can be used by process design practitioners. Reasonable first-order estimates of activity coefficients in the relevant media are needed rather than an incremental improvement in theoretical approaches which are not usable by practitioners. A comparison of the Electrolyte Non-Random Two-Liquid (ENRTL) and Pitzer ion-interaction models for the thermodynamic representation of SBW is presented. It is concluded that Pitzer's model is superior to ENRTL in modeling treatment processes for SBW. The applicability of the Pitzer treatment to high concentrations of pertinent species and to the determination of solubilities and chemical equilibria is addressed. Alternate values of Pitzer parameters for HCl, H2SO4, and HNO3 are proposed, applicable up to 16m, and 12m, respectively. Partial validation of the implementation of Pitzer's treatment within the commercial process simulator ASPEN Plus was performed.

  4. The New Method of Determining Tank Reasonable Safe Distance Based on Pool Fire Thermal Radiation Model%基于池火热辐射模型确定储罐合理安全距离新方法

    Institute of Scientific and Technical Information of China (English)

    赵建强; 刘迅; 刘翀; 吕黎军; 马伟平

    2016-01-01

    It was very important to determine tank reasonable distance for raising the tank safe design level. The paper expounded the tank safe distance difference of domestic and for-eign standards. In allusion to the mainly floating tank fire accident forms, the limitation of domestic standard for tank safe distance was assessed, that is the current standard can not meet the safe requirement in the case of tank full exposure fire.By referring the tank pool fire ther-mal radiation model,the oil floating tank safe distance was obtained under critical thermal ra-diation strength. Finally, the paper put forward the principle of determining tank reasonable distance, with the comprehensive utilization of domestic standard and tank pool fire thermal radiation model and tank technological parameter. For less than 10 x 104 m3 tank as far as pos-sible to increase storage tank fire separation;for more than 10 x 104 m3 tank,the fire preven-tion span basic can meet the safety requirements of the current domestic standards.%研究确定储罐合理的防火间距,对于提高储罐安全设计水平具有重要意义。基于浮顶罐主要火灾事故类型,评价了国内标准关于储罐安全距离的局限性,即现有标准不能满足储罐全面积敞口火灾情况下的安全要求。基于储罐池火热辐射数学模型,计算出原油外浮顶罐在临界热辐射强度对应的储罐安全距离。新建储罐工程在满足国内标准基础上,建议结合储罐池火热辐射数学模型计算结果,综合考虑储罐防火堤面积、油品性质以及罐区消防设施能力。对于10×104 m3以下储罐应尽可能增加储罐防火间距,对于10×104 m3以上储罐,其防火间距基本可满足现行国内标准规定的安全要求。

  5. Theoretical comparison between solar combisystems based on bikini tanks and tank-in-tank solar combisystems

    DEFF Research Database (Denmark)

    Yazdanshenas, Eshagh; Furbo, Simon; Bales, Chris

    2008-01-01

    Theoretical investigations have shown that solar combisystems based on bikini tanks for low energy houses perform better than solar domestic hot water systems based on mantle tanks. Tank-in-tank solar combisystems are also attractive from a thermal performance point of view. In this paper......, theoretical comparisons between solar combisystems based on bikini tanks and tank-in-tank solar combisystems are presented....

  6. Numerical modeling of heat transfer in the fuel oil storage tank at thermal power plant

    Directory of Open Access Journals (Sweden)

    Kuznetsova Svetlana A.

    2015-01-01

    Full Text Available Presents results of mathematical modeling of convection of a viscous incompressible fluid in a rectangular cavity with conducting walls of finite thickness in the presence of a local source of heat in the bottom of the field in terms of convective heat exchange with the environment. A mathematical model is formulated in terms of dimensionless variables “stream function – vorticity vector speed – temperature” in the Cartesian coordinate system. As the results show the distributions of hydrodynamic parameters and temperatures using different boundary conditions on the local heat source.

  7. Tank characterization report: Tank 241-C-109

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, B.C.; Borshiem, G.L.; Jensen, L.

    1993-09-01

    Single-shell tank 241-C-109 is a Hanford Site Ferrocyanide Watch List tank that was most recently sampled in September 1992. Analyses of materials obtained from tank 241-C-109 were conducted to support the resolution of the ferrocyanide unreviewed safety question (USQ) and to support Hanford Federal Facility Agreement and consent Order (Tri- Party Agreement) Milestone M-10-00. This report describes this analysis.

  8. Ditching Tests of a 1/9-Size Model of the Army P-38 Airplane in Langley Tank No. 2 and at the Outdoor Catapult

    Science.gov (United States)

    Jarvis, George A.; Cederborg, Gibson A.

    1946-01-01

    A dynamically similar model of the Army P-38 airplane was tested to determine the best way to land this airplane on the water and to determine its probable ditching performance. The tests consisted of ditching the model at various landing attitudes, flap settings, speeds, weights, and conditions of simulated damage. The model was ditched in calm water from the tank towing carriage and a few ditching were made in both calm and rough water at the outdoor catapult. The performance of the model was determined by making visual observations, by recording lengths of run and time histories of decelerations, and by taking motion pictures of the ditchings.

  9. Predictive Models for the Determination of Pitting Corrosion Versus Inhibitor Concentrations and Temperature for Radioactive Sludge in Carbon Steel Waste Tanks

    Energy Technology Data Exchange (ETDEWEB)

    Mickalonis, J.I.

    1998-10-06

    Statistical models have been developed to predict the occurrence of pitting corrosion in carbon steel waste storage tanks exposed to radioactive nuclear waste. The levels of nitrite concentrations necessary to inhibit pitting at various temperatures and nitrate concentrations were experimentally determined via electrochemical polarization and coupon immersion corrosion tests. Models for the pitting behavior were developed based on various statistical analyses of the experimental data. Feed-forward Artificial Neural Network (ANN) models, trained using the Back-Propagation of Error Algorithm, more accurately predicted conditions at which pitting occurred than the logistic regression models developed using the same data.

  10. Differential Evolution Algorithm for System Identification and Tuning of a Fuzzy Modified Model Reference Adaptive Controller for a Coupled Tank Level Process

    Directory of Open Access Journals (Sweden)

    K. Asan Mohideen

    2014-07-01

    Full Text Available Improving the transient performance of the MRAC has been a point of research for a long time. The main objective of the paper is to design an MRAC with improved transient and steady state performance. This paper proposes a Fuzzy modified MRAC (FMRAC to control a coupled tank level process. The FMRAC uses a proportional control based Mamdani-type Fuzzy inference system (MFIS to improve the transient performance of a direct MRAC. In addition, it proposes the application of Differential Evolution (DE algorithm to tune the membership function parameters off-line of the FMRAC to improve its performance further. The proposed controller is called DE based Fuzzy Modified Model Reference Adaptive Controller (DEFMRAC. In this study, an MRAC, an FMRAC and the proposed DEFMRAC are designed for a coupled tank level process and their performances are compared. The coupled tank level process is modeled by using system identification procedure and the accuracy of the resultant model is further improved by parameter tuning using DE. The simulation results show that the FMRAC gives better transient performance than the direct MRAC. The results also show that the proposed DEFMRAC gives better transient performance than the direct MRAC or the FMRAC. It is concluded that the proposed controller can be used to obtain very good transient and steady state performance in the control of nonlinear processes.

  11. Linking Physical and Numerical Modelling in Hydrogeology Using Sand Tank Experiments and Comsol Multiphysics

    Science.gov (United States)

    Singha, Kamini; Loheide, Steven P., II

    2011-01-01

    Visualising subsurface processes in hydrogeology and building intuition for how these processes are controlled by changes in forcing is hard for many undergraduate students. While numerical modelling is one way to help undergraduate students explore outcomes of multiple scenarios, many codes are not user-friendly with respect to defining domains,…

  12. Tank evaluation system shielded annular tank application

    Energy Technology Data Exchange (ETDEWEB)

    Freier, D.A.

    1988-10-04

    TEST (Tank Evaluation SysTem) is a research project utilizing neutron interrogation techniques to analyze the content of nuclear poisons and moderators in tank shielding. TEST experiments were performed on an experimental SAT (Shielded Annular Tank) at the Rocky Flats Plant. The purpose of these experiments was threefold: (1) to assess TEST application to SATs, (2) to determine if Nuclear Safety inspection criteria could be met, and (3) to perform a preliminary calibration of TEST for SATs. Several experiments were performed, including measurements of 11 tank shielding configurations, source-simulated holdup experiments, analysis of three detector modes, resolution studies, and TEST scanner geometry experiments. 1 ref., 21 figs., 4 tabs.

  13. Simple characterisation of solar DHW tanks

    DEFF Research Database (Denmark)

    Andersen, Elsa; Furbo, Simon

    1998-01-01

    The aim of the project is to compare different methods used for testing small solar domestic hot water tanks. A small hot water tank is tested at three different European laboratories by means of the test methods normally used at the laboratories. The tank is marketed in Denmark.The test carried...... out at the Department for Buildings and Energy compromises determination of the heat loss coefficient for the tank and the heat transfer coefficient for the auxiliary helix. A dynamic test is performed and a simulation model of the tank is made and validated against measured energy quantities...... and temperatures. The annual thermal performance for a solar domestic hot water system based on the tested tank is calculated. Further, proposal for a future test on mixing during draw-off as well as proposal for a maximum acceptable mixing during draw-off is given....

  14. Computational Analyses of Pressurization in Cryogenic Tanks

    Science.gov (United States)

    Ahuja, Vineet; Hosangadi, Ashvin; Mattick, Stephen; Lee, Chun P.; Field, Robert E.; Ryan, Harry

    2008-01-01

    A) Advanced Gas/Liquid Framework with Real Fluids Property Routines: I. A multi-fluid formulation in the preconditioned CRUNCH CFD(Registered TradeMark) code developed where a mixture of liquid and gases can be specified: a) Various options for Equation of state specification available (from simplified ideal fluid mixtures, to real fluid EOS such as SRK or BWR models). b) Vaporization of liquids driven by pressure value relative to vapor pressure and combustion of vapors allowed. c) Extensive validation has been undertaken. II. Currently working on developing primary break-up models and surface tension effects for more rigorous phase-change modeling and interfacial dynamics B) Framework Applied to Run-time Tanks at Ground Test Facilities C) Framework Used For J-2 Upper Stage Tank Modeling: 1) NASA MSFC tank pressurization: a) Hydrogen and oxygen tank pre-press, repress and draining being modeled at NASA MSFC. 2) NASA AMES tank safety effort a) liquid hydrogen and oxygen are separated by a baffle in the J-2 tank. We are modeling pressure rise and possible combustion if a hole develops in the baffle and liquid hydrogen leaks into the oxygen tank. Tank pressure rise rates simulated and risk of combustion evaluated.

  15. Experimental Wave Tank Test for Reference Model 3 Floating-Point Absorber Wave Energy Converter Project

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Y. H. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lawson, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Li, Y. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Previsic, M. [Re Vision Consulting, Sacramento, CA (United States); Epler, J. [Re Vision Consulting, Sacramento, CA (United States); Lou, J. [Oregon State Univ., Corvallis, OR (United States)

    2015-01-01

    The U.S. Department of Energy established a reference model project to benchmark a set of marine and hydrokinetic technologies including current (tidal, open-ocean, and river) turbines and wave energy converters. The objectives of the project were to first evaluate the status of these technologies and their readiness for commercial applications. Second, to evaluate the potential cost of energy and identify cost-reduction pathways and areas where additional research could be best applied to accelerate technology development to market readiness.

  16. Study on evaluation model of earthquake damage to clean water tank%清水池震害评估模型研究

    Institute of Scientific and Technical Information of China (English)

    高霖; 郭恩栋; 刘智; 洪广磊

    2013-01-01

    In order to assess the seismic damage of clean water tanks, based on the detailed earthquake damage data of clean water tanks from Haicheng earthquake and Tangshan earthquake, the phenomena and characteristics of clean water tanks subjected to earthquake damage are analyzed and the main influence factors are found. The least square method is used in the regression analysis of the earthquake damage data to obtained the regression coefficients of influence factors of earthquake damage under different conditions and to establish an empirical model to evaluate the earthquake damage of clean water tanks. The correlation coefficient of the model is 0. 661 and the standard deiation is 0.447. The model has an accuracy of 91. 2% by the regression discriminant analysis. According to the earthquake experience, the adjustment coefficients for new influence factors that are not considered in the model are given. Evaluation results are consistent with the actual damage to the clean water tanks in Wenchuan earthquake and Yushu earthquake, and etc. Thus, the model is preliminarily proved to be reliable.%为了评估清水池的地震破坏状态,基于海城地震、唐山地震中较详细的水池震害资料,分析了水池的主要震害现象、特征,并找出了影响水池震害的主要因素.采用最小二乘法对震害数据进行回归分析,得到了各震害影响因素不同情况下的回归系数取值,从而建立了清水池震害经验统计回归模型.经计算该模型的相关系数为0.661,标准差为0.447.经回判分析,模型回判成功率为91.2%.对于模型中未考虑到的震害影响因素,根据实际震害经验,给出新增影响因素的建议系数.对汶川、玉树等地震中遭到破坏的清水池进行评估,结果与实际震害基本相符,初步验证了该评估模型的可靠性.

  17. A general tank test of a model of the hull of the Pem-1 flying boat including a special working chart for the determination of hull performance

    Science.gov (United States)

    Dawson, John R

    1938-01-01

    The results of a general tank test of a 1/6 full-size model of the hull of the Pem-1 flying boat (N.A.C.A. model 18) are given in non-dimensional form. In addition to the usual curves, the results are presented in a new form that makes it possible to apply them more conveniently than in the forms previously used. The resistance was compared with that of N.A.C.A. models 11-C and 26(Sikorsky S-40) and was found to be generally less than the resistance of either.

  18. Influence of sway motion on passive anti-rolling tank

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The passive anti-rolling tank is one of important ship stabilizers widely used today. But at present, research of the tank is most aimed at its rolling movement. In this paper, the influence of sway motion on the passive anti-rolling tank is considered, the mathematical model of "ship-passive anti-rolling tank" system coupled with sway motion is developed basing on the U-shaped passive anti-rolling tank theory. Both simulation results and experimental data indicate that it is necessary to consider the influence of sway motion on the anti-rolling tank, which is more agreeable to the actual circumstance.

  19. Think tanks in Denmark

    DEFF Research Database (Denmark)

    Ørsten, Mark; Nørgaard Kristensen, Nete

    2016-01-01

    outside the media. The study shows that the two largest and oldest think tanks in Denmark, the liberal think tank CEPOS and the social democratic think tank ECLM, are very active and observable in the media; that the media’s distribution of attention to these think tanks, to some extent, confirms a re......Though think tanks have a long history internationally, they have especially in recent years come to play an increasingly important role in both policy-formulation and public debate. In this article, we analyse the growing presence of think tanks in a Danish context during the 2000s and the first...... half of the 2010s, because in this national setting think tanks are still a relatively new phenomenon. Based on theories of mediatization and de-corporatization, we present 1) an analysis of the visibility of selected Danish think tanks in the media and 2) an analysis of their political networks...

  20. Tank 241-TX-118 tank characterization plan

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, B.C.

    1994-12-09

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, Oak Ridge National Laboratory, and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from tank 241-TX-118.

  1. Tank 241-TX-105 tank characterization plan

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, B.C.

    1995-01-01

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, WHC 222-S Laboratory, Oak Ridge National Laboratory, and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from tank 241-TX-105.

  2. Tank 241-BX-104 tank characterization plan

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, B.C.

    1994-12-14

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, Oak Ridge National Laboratory, and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from tank 241-BX-104.

  3. Radiotracer investigation in gold leaching tanks.

    Science.gov (United States)

    Dagadu, C P K; Akaho, E H K; Danso, K A; Stegowski, Z; Furman, L

    2012-01-01

    Measurement and analysis of residence time distribution (RTD) is a classical method to investigate performance of chemical reactors. In the present investigation, the radioactive tracer technique was used to measure the RTD of aqueous phase in a series of gold leaching tanks at the Damang gold processing plant in Ghana. The objective of the investigation was to measure the effective volume of each tank and validate the design data after recent process intensification or revamping of the plant. I-131 was used as a radioactive tracer and was instantaneously injected into the feed stream of the first tank and monitored at the outlet of different tanks. Both sampling and online measurement methods were used to monitor the tracer concentration. The results of measurements indicated that both the methods provided identical RTD curves. The mean residence time (MRT) and effective volume of each tank was estimated. The tanks-in-series model with exchange between active and stagnant volume was used and found suitable to describe the flow structure of aqueous phase in the tanks. The estimated effective volume of the tanks and high degree of mixing in tanks could validate the design data and confirmed the expectation of the plant engineer after intensification of the process.

  4. Tank 241-AZ-101 tank characterization plan

    Energy Technology Data Exchange (ETDEWEB)

    Schreiber, R.D.

    1995-02-06

    The Defense Nuclear Facilities Safety Board has advised the DOE to concentrate the near-term sampling and analysis activities on identification and resolution of safety issues. The Data Quality Objective (DQO) process was chosen as a tool to be used in the resolution of safety issues. As a result, A revision in the Federal Facilities Agreement and Consent Order (Tri-Party Agreement) milestone M-44 has been made, which states that ``A Tank Characterization Plan (TCP) will also be developed for each double-shell tank (DST) and single-shell tank (SST) using the DQO process. Development of TCPs by the DQO process is intended to allow users to ensure their needs will be met and that resources are devoted to gaining only necessary information``. This document satisfies that requirement for Tank 241-AZ-101 (AZ-101) sampling activities. Tank AZ-101 is currently a non-Watch List tank, so the only DQOs applicable to this tank are the safety screening DQO and the compatibility DQO, as described below. The contents of Tank AZ-101, as of October 31, 1994, consisted of 3,630 kL (960 kgal) of dilute non-complexed waste and aging waste from PUREX (NCAW, neutralized current acid waste). Tank AZ-101 is expected to have two primary layers. The bottom layer is composed of 132 kL of sludge, and the top layer is composed of 3,500 kL of supernatant, with a total tank waste depth of approximately 8.87 meters.

  5. Tank 241-AZ-102 tank characterization plan

    Energy Technology Data Exchange (ETDEWEB)

    Schreiber, R.D.

    1995-02-06

    The Defense Nuclear Facilities Safety Board has advised the DOE to concentrate the near-term sampling and analysis activities on identification and resolution of safety issues. The Data Quality Objective (DQO) process was chosen as a tool to be used in the resolution of safety issues. As a result, a revision in the Federal Facilities Agreement and Consent Order (Tri-Party Agreement) milestone M-44 has been made, which states that ``A Tank Characterization Plan (TCP) will also be developed for each double-shell tank (DST) and single-shell tank (SST) using the DQO process ... Development of TCPs by the DQO process is intended to allow users to ensure their needs will be met and that resources are devoted to gaining only necessary information``. This document satisfies that requirement for tank 241-AZ-102 (AZ-102) sampling activities. Tank AZ-102 is currently a non-Watch List tank, so the only DQOs applicable to this tank are the safety screening DQO and the compatibility DQO, as described below. The current contents of Tank AZ-102, as of October 31, 1994, consisted of 3,600 kL (950 kgal) of dilute non-complexed waste and aging waste from PUREX (NCAW, neutralized current acid waste). Tank AZ-102 is expected to have two primary layers. The bottom layer is composed of 360 kL of sludge, and the top layer is composed of 3,240 kL of supernatant, with a total tank waste depth of approximately 8.9 meters.

  6. Feed tank transfer requirements

    Energy Technology Data Exchange (ETDEWEB)

    Freeman-Pollard, J.R.

    1998-09-16

    This document presents a definition of tank turnover; DOE responsibilities; TWRS DST permitting requirements; TWRS Authorization Basis (AB) requirements; TWRS AP Tank Farm operational requirements; unreviewed safety question (USQ) requirements; records and reporting requirements, and documentation which will require revision in support of transferring a DST in AP Tank Farm to a privatization contractor for use during Phase 1B.

  7. 基于CFD的潜艇模型水池试验方法研究%Test method of submarine model test in towing tank by CFD

    Institute of Scientific and Technical Information of China (English)

    郑亚雄; 史圣哲; 许靖锋

    2016-01-01

    The submarine model test in a towing tank is greatly different from the test conducted under the unlimited condition. This paper studies the inlfuences of the connection device in test and the size of the towing tank size on the submarine model test by the computational lfuid dynamic(CFD) method. The submarine sailing in the unlimited condition is ifrstly simulated to check and evaluate the CFD settings. Then, the submarine model test in towing tank is modeled and calculated. The results are analyzed to investigate the effects of the connection devices, the side wall and the bottom on the force measurement. Finally, the numerical simulation results are combined with the model test results to verify the feasibility of the test facilities.%潜艇水池试验与深广水域航行区别很大,采用计算流体力学(CFD)方法研究试验连接装置及试验水池尺度对潜艇试验的影响。首先对深广水域的潜艇进行计算,以此来校核CFD算法;然后对潜艇试验实况进行建模计算,根据计算结果来分析模型连接件、池壁和池底效应等对于潜艇受力测试的影响;最后结合实际试验和仿真计算结果,分析并证明试验装置的可行性。

  8. LIFE ESTIMATION OF HIGH LEVEL WASTE TANK STEEL FOR F-TANK FARM CLOSURE PERFORMANCE ASSESSMENT

    Energy Technology Data Exchange (ETDEWEB)

    Subramanian, K

    2007-10-01

    calculation can be followed, once a better understanding of the concrete degradation and consequent diffusion rates is developed. A stochastic approach was also followed to estimate the distributions of failures based upon the same mechanisms of corrosion, but accounting for variances in each of the independent variables. The recommended distributions for time to failure of the tank liner for use in stochastic modeling are shown in Table 3. The distributions are based upon based upon known parameters of SRS waste tank construction and groundwater analyses. The results recommended for modeling are based upon discrete diffusion coefficients of 1 x 10{sup -6} cm{sup 2}/sec for oxygen diffusion as well as CO{sub 2} diffusion.

  9. Evaluation of Liquid Dynamic Loads in Slack LNG Cargo Tanks

    Science.gov (United States)

    1980-05-01

    Absirect This report provides an evaluacion of dynimi,c sloshing loads in slack LNG cargo tanks. A comprehensive review of vcrid4ide scale model sloshing...Cycles at Transducer Location 1 for a 25% Full Tank .......................................... 69 IV-7 Integrated Nondimensional Pressure Values for...Location 14 for a 75% Full Tank ......................................................... 70 IV 12 Integrated Nondimensional Pressure Values for 200

  10. Think Tanks in Europe

    DEFF Research Database (Denmark)

    Kelstrup, Jesper Dahl

    The emergence of more think tanks in recent decades has spawned some interest in how they function and impact policy-making in the European Union and its member states. So far however few empirical studies of think tanks have been carried out and think tanks have mainly been studied...... in their national contexts. Questions regarding patterns and differences in think tank organisations and functions across countries have largely been left unanswered. This paper advances a definition and research design that uses different expert roles to categorise think tanks. A sample of 34 think tanks from...... Brussels, Denmark and Germany are categorised according to different expert roles in a pilot analysis. As the analysis is sensitive to the interpretation and weight given to different indicators, besides from picturing the think tank landscape, the analysis is intended to trigger a discussion of how...

  11. [High Pressure Gas Tanks

    Science.gov (United States)

    Quintana, Rolando

    2002-01-01

    Four high-pressure gas tanks, the basis of this study, were especially made by a private contractor and tested before being delivered to NASA Kennedy Space Center. In order to insure 100% reliability of each individual tank the staff at KSC decided to again submit the four tanks under more rigorous tests. These tests were conducted during a period from April 10 through May 8 at KSC. This application further validates the predictive safety model for accident prevention and system failure in the testing of four high-pressure gas tanks at Kennedy Space Center, called Continuous Hazard Tracking and Failure Prediction Methodology (CHTFPM). It is apparent from the variety of barriers available for a hazard control that some barriers will be more successful than others in providing protection. In order to complete the Barrier Analysis of the system, a Task Analysis and a Biomechanical Study were performed to establish the relationship between the degree of biomechanical non-conformities and the anomalies found within the system on particular joints of the body. This relationship was possible to obtain by conducting a Regression Analysis to the previously generated data. From the information derived the body segment with the lowest percentage of non-conformities was the neck flexion with 46.7%. Intense analysis of the system was conducted including Preliminary Hazard Analysis (PHA), Failure Mode and Effect Analysis (FMEA), and Barrier Analysis. These analyses resulted in the identification of occurrences of conditions, which may be becoming hazardous in the given system. These conditions, known as dendritics, may become hazards and could result in an accident, system malfunction, or unacceptable risk conditions. A total of 56 possible dendritics were identified. Work sampling was performed to observe the occurrence each dendritic. The out of control points generated from a Weighted c control chart along with a Pareto analysis indicate that the dendritics "Personnel not

  12. Safety criteria for organic watch list tanks at the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    Meacham, J.E., Westinghouse Hanford

    1996-08-01

    This document reviews the hazards associated with the storage of organic complexant salts in Hanford Site high-level waste single- shell tanks. The results of this analysis were used to categorize tank wastes as safe, unconditionally safe, or unsafe. Sufficient data were available to categorize 67 tanks; 63 tanks were categorized as safe, and four tanks were categorized as conditionally safe. No tanks were categorized as unsafe. The remaining 82 SSTs lack sufficient data to be categorized.Historic tank data and an analysis of variance model were used to prioritize the remaining tanks for characterization.

  13. Dynamic modelling of an adsorption storage tank using a hybrid approach combining computational fluid dynamics and process simulation

    Science.gov (United States)

    Mota, J.P.B.; Esteves, I.A.A.C.; Rostam-Abadi, M.

    2004-01-01

    A computational fluid dynamics (CFD) software package has been coupled with the dynamic process simulator of an adsorption storage tank for methane fuelled vehicles. The two solvers run as independent processes and handle non-overlapping portions of the computational domain. The codes exchange data on the boundary interface of the two domains to ensure continuity of the solution and of its gradient. A software interface was developed to dynamically suspend and activate each process as necessary, and be responsible for data exchange and process synchronization. This hybrid computational tool has been successfully employed to accurately simulate the discharge of a new tank design and evaluate its performance. The case study presented here shows that CFD and process simulation are highly complementary computational tools, and that there are clear benefits to be gained from a close integration of the two. ?? 2004 Elsevier Ltd. All rights reserved.

  14. 33 CFR 157.15 - Slop tanks in tank vessels.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Slop tanks in tank vessels. 157... (CONTINUED) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design, Equipment, and Installation § 157.15 Slop tanks in tank vessels. (a) Number....

  15. 49 CFR 174.63 - Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank...

  16. Lifecycle Verification of Tank Liner Polymers

    Energy Technology Data Exchange (ETDEWEB)

    Anovitz, Lawrence {Larry} M [ORNL; Smith, Barton [ORNL

    2014-03-01

    This report describes a method that was developed for the purpose of assessing the durability of thermoplastic liners used in a Type IV hydrogen storage tank during the tank s expected service life. In the method, a thermoplastic liner specimen is cycled between the maximum and minimum expected working temperatures while it is differentially pressurized with high-pressure hydrogen gas. The number of thermal cycling intervals corresponds to those expected within the tank s design lifetime. At prescribed intervals, hydrogen permeation measurements are done in situ to assess the ability of the liner specimen to maintain its hydrogen barrier properties and to model its permeability over the tank lifetime. Finally, the model is used to assess whether the steady-state leakage rate in the tank could potentially exceed the leakage specification for hydrogen fuel cell passenger vehicles. A durability assessment was performed on a specimen of high-density polyethylene (HDPE) that is in current use as a tank liner. Hydrogen permeation measurements were performed on several additional tank liner polymers as well as novel polymers proposed for use as storage tank liners and hydrogen barrier materials. The following technical barriers from the Fuel Cell Technologies Program MYRDD were addressed by the project: D. Durability of on-board storage systems lifetime of at least 1500 cycles G. Materials of construction vessel containment that is resistant to hydrogen permeation M. Lack of Tank Performance Data and Understanding of Failure Mechanisms And the following technical targets1 for on-board hydrogen storage systems R&D were likewise addressed: Operational cycle life (1/4 tank to full) FY 2017: 1500 cycles; Ultimate: 1500 cycles Environmental health & safety Permeation and leakage: Meets or exceeds applicable standards Loss of useable H2: FY 2017: 0.05 g/h/kg H2; Ultimate: 0.05 g/h/kg H2

  17. Lifecycle Verification of Tank Liner Polymers

    Energy Technology Data Exchange (ETDEWEB)

    Anovitz, Lawrence {Larry} M [ORNL; Smith, Barton [ORNL

    2014-03-01

    This report describes a method that was developed for the purpose of assessing the durability of thermoplastic liners used in a Type IV hydrogen storage tank during the tank s expected service life. In the method, a thermoplastic liner specimen is cycled between the maximum and minimum expected working temperatures while it is differentially pressurized with high-pressure hydrogen gas. The number of thermal cycling intervals corresponds to those expected within the tank s design lifetime. At prescribed intervals, hydrogen permeation measurements are done in situ to assess the ability of the liner specimen to maintain its hydrogen barrier properties and to model its permeability over the tank lifetime. Finally, the model is used to assess whether the steady-state leakage rate in the tank could potentially exceed the leakage specification for hydrogen fuel cell passenger vehicles. A durability assessment was performed on a specimen of high-density polyethylene (HDPE) that is in current use as a tank liner. Hydrogen permeation measurements were performed on several additional tank liner polymers as well as novel polymers proposed for use as storage tank liners and hydrogen barrier materials. The following technical barriers from the Fuel Cell Technologies Program MYRDD were addressed by the project: D. Durability of on-board storage systems lifetime of at least 1500 cycles G. Materials of construction vessel containment that is resistant to hydrogen permeation M. Lack of Tank Performance Data and Understanding of Failure Mechanisms And the following technical targets1 for on-board hydrogen storage systems R&D were likewise addressed: Operational cycle life (1/4 tank to full) FY 2017: 1500 cycles; Ultimate: 1500 cycles Environmental health & safety Permeation and leakage: Meets or exceeds applicable standards Loss of useable H2: FY 2017: 0.05 g/h/kg H2; Ultimate: 0.05 g/h/kg H2

  18. TANK MIXING STUDY WITH FLOW RECIRCULATION

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.

    2014-06-25

    The primary objective of this work is to quantify the mixing time when two miscible fluids are mixed by one recirculation pump and to evaluate adequacy of 2.5 hours of pump recirculation to be considered well mixed in SRS tanks, JT-71/72. The work scope described here consists of two modeling analyses. They are the steady state flow pattern analysis during pump recirculation operation of the tank liquid and transient species transport calculations based on the initial steady state flow patterns. The modeling calculations for the mixing time are performed by using the 99% homogeneity criterion for the entire domain of the tank contents.

  19. ALGORITHM FOR THE CREATION OF THE WIREFRAME MODEL OF A FIXED ROOF FOR A FUEL STORAGE TANK IN FORM OF GEODESIC DOME

    Directory of Open Access Journals (Sweden)

    Yamill Santiago Campos Pérez

    2015-01-01

    Full Text Available A geodesic dome is a mesh of bars and nodes arranged along the edges and vertices of a polyhedron on a surface that can be in the form of a sphere, parabola or ellipse. From knowing the advantages of this type of structure, they have been widely used in various constructions such as: housing, commercial offices, greenhouses, fair stand, fixed ceilings fuel storage tanks, among others. Many researchers have studied modeling and geometry of geodesic domes. The purpose of this paper is to present, from the review and compilation of information from several researches, an algorithm for generating a wireframe model of a geodesic dome for fixed roofs of spherical fuel storage tanks, for a further analysis of resistance by the method of finite elements. In this paper, we describe in detail the procedure and geometric expressions that were used. Finally, a computer program was developed in order to evaluate mathematical expressions and the procedure described in this paper and also to have a tool for generating computational model of a geodesic dome.

  20. Analysis of nodalization effects on the prediction error of generalized finite element method used for dynamic modeling of hot water storage tank

    Directory of Open Access Journals (Sweden)

    Wołowicz Marcin

    2015-09-01

    Full Text Available The paper presents dynamic model of hot water storage tank. The literature review has been made. Analysis of effects of nodalization on the prediction error of generalized finite element method (GFEM is provided. The model takes into account eleven various parameters, such as: flue gases volumetric flow rate to the spiral, inlet water temperature, outlet water flow rate, etc. Boiler is also described by sizing parameters, nozzle parameters and heat loss including ambient temperature. The model has been validated on existing data. Adequate laboratory experiments were provided. The comparison between 1-, 5-, 10- and 50-zone boiler is presented. Comparison between experiment and simulations for different zone numbers of the boiler model is presented on the plots. The reason of differences between experiment and simulation is explained.

  1. Temperature Stratification in a Cryogenic Fuel Tank

    Data.gov (United States)

    National Aeronautics and Space Administration — A reduced dynamical model describing temperature stratification effects driven by natural convection in a liquid hydrogen cryogenic fuel tank has been developed. It...

  2. Fuel Tank Technology

    Science.gov (United States)

    1989-11-01

    structures b) - Equal thermic inertia c) - Equal fluid volume d) - Equal pressure variation on both wings at the change of the room temperature - This...individual fuel sections. Each fuel section is further ccmpartmentated by metall tank shear walls and tank floors into three individual fuel cells to...plate Dy a stretch forming process, and the metallic tank floors . The air intake segments extend from one bulkhead to the other, thus reducing assembly

  3. Fuel reprocessing tank

    Energy Technology Data Exchange (ETDEWEB)

    Gonda, Sumitora

    1998-10-09

    A tank of the present invention for spent fuels comprises a stainless steel tank main body for storing a highly corrosive dissolving solution, a steam jet pump disposed to the inside of the tank main body for transferring the dissolving solution to the outside of the tank main body and pipelines connecting them. With such a constitution, abnormal abrasion and drag of mechanical parts are less caused. In addition, a cleaning nozzle and a cleaning liquid pipeline which eliminates clogging of a sucking port of the steam jet pump if clogging is caused by sludges are disposed thereby enabling to avoid possibility of clogging. (T.M.)

  4. Hanford tanks initiative plan

    Energy Technology Data Exchange (ETDEWEB)

    McKinney, K.E.

    1997-07-01

    Abstract: The Hanford Tanks Initiative (HTI) is a five-year project resulting from the technical and financial partnership of the U.S. Department of Energy`s Office of Waste Management (EM-30) and Office of Science and Technology Development (EM-50). The HTI project accelerates activities to gain key technical, cost performance, and regulatory information on two high-level waste tanks. The HTI will provide a basis for design and regulatory decisions affecting the remainder of the Tank Waste Remediation System`s tank waste retrieval Program.

  5. Evaluation of transverse dispersion effects in tank experiments by numerical modeling: parameter estimation, sensitivity analysis and revision of experimental design.

    Science.gov (United States)

    Ballarini, E; Bauer, S; Eberhardt, C; Beyer, C

    2012-06-01

    Transverse dispersion represents an important mixing process for transport of contaminants in groundwater and constitutes an essential prerequisite for geochemical and biodegradation reactions. Within this context, this work describes the detailed numerical simulation of highly controlled laboratory experiments using uranine, bromide and oxygen depleted water as conservative tracers for the quantification of transverse mixing in porous media. Synthetic numerical experiments reproducing an existing laboratory experimental set-up of quasi two-dimensional flow through tank were performed to assess the applicability of an analytical solution of the 2D advection-dispersion equation for the estimation of transverse dispersivity as fitting parameter. The fitted dispersivities were compared to the "true" values introduced in the numerical simulations and the associated error could be precisely estimated. A sensitivity analysis was performed on the experimental set-up in order to evaluate the sensitivities of the measurements taken at the tank experiment on the individual hydraulic and transport parameters. From the results, an improved experimental set-up as well as a numerical evaluation procedure could be developed, which allow for a precise and reliable determination of dispersivities. The improved tank set-up was used for new laboratory experiments, performed at advective velocities of 4.9 m d(-1) and 10.5 m d(-1). Numerical evaluation of these experiments yielded a unique and reliable parameter set, which closely fits the measured tracer concentration data. For the porous medium with a grain size of 0.25-0.30 mm, the fitted longitudinal and transverse dispersivities were 3.49×10(-4) m and 1.48×10(-5) m, respectively. The procedures developed in this paper for the synthetic and rigorous design and evaluation of the experiments can be generalized and transferred to comparable applications.

  6. Extended continuous-flow stirred-tank reactor (ECSTR) as a simple model of life under thermodynamically open conditions

    Science.gov (United States)

    Takinoue, Masahiro; Ma, Yue; Mori, Yoshihito; Yoshikawa, Kenichi

    2009-07-01

    A continuous-flow stirred-tank reactor (CSTR) is a vital tool for investigating the nonlinear dynamics of chemical systems. This report proposes an extended CSTR (ECSTR) inspired by active and passive transports through a closed membrane in living systems. In addition to the externally-controlled flow in a conventional CSTR, we introduce passive diffusion through a membrane into the ECSTR. This extension allows us to control the chemical dynamics with a larger parameter-dimension. Numerical analyses show that the ECSTR can expand an oscillatory region in the parameter space and can convert a non-oscillatory chemical system to an oscillatory system.

  7. Hydrodynamic Tests in the N.A.C.A. Tank of a Model of the Hull of the Short Calcutta Flying Boat

    Science.gov (United States)

    Ward, Kenneth E

    1937-01-01

    The hydrodynamic characteristics of a model of the hull of the Short Calcutta (N.A.C.A. Model 47) are presented in non-dimensional form. This model represents one of a series of hulls of successful foreign and domestic flying boats the characteristics of which are being obtained under similar test conditions in the N.A.C.A. tank. The take-off distance and time for a flying boat having the hull of the Calcutta are compared at two values of the gross load with the corresponding distances and times for the same flying boat having hulls of two representative American types, the Sikorsky S-40 and the N.A.C.A. 11-A. This comparison indicates that for hulls of the widely different forms compared, the differences in take-off time and distance are negligible.

  8. Runtime and Pressurization Analyses of Propellant Tanks

    Science.gov (United States)

    Field, Robert E.; Ryan, Harry M.; Ahuja, Vineet; Hosangadi, Ashvin; Lee, Chung P.

    2007-01-01

    Multi-element unstructured CFD has been utilized at NASA SSC to carry out analyses of propellant tank systems in different modes of operation. The three regimes of interest at SSC include (a) tank chill down (b) tank pressurization and (c) runtime propellant draw-down and purge. While tank chill down is an important event that is best addressed with long time-scale heat transfer calculations, CFD can play a critical role in the tank pressurization and runtime modes of operation. In these situations, problems with contamination of the propellant by inclusion of the pressurant gas from the ullage causes a deterioration of the quality of the propellant delivered to the test article. CFD can be used to help quantify the mixing and propellant degradation. During tank pressurization under some circumstances, rapid mixing of relatively warm pressurant gas with cryogenic propellant can lead to rapid densification of the gas and loss of pressure in the tank. This phenomenon can cause serious problems during testing because of the resulting decrease in propellant flow rate. With proper physical models implemented, CFD can model the coupling between the propellant and pressurant including heat transfer and phase change effects and accurately capture the complex physics in the evolving flowfields. This holds the promise of allowing the specification of operational conditions and procedures that could minimize the undesirable mixing and heat transfer inherent in propellant tank operation. It should be noted that traditional CFD modeling is inadequate for such simulations because the fluids in the tank are in a range of different sub-critical and supercritical states and elaborate phase change and mixing rules have to be developed to accurately model the interaction between the ullage gas and the propellant. We show a typical run-time simulation of a spherical propellant tank, containing RP-1 in this case, being pressurized with room-temperature nitrogen at 540 R. Nitrogen

  9. Analysis of multiple tank car releases in train accidents.

    Science.gov (United States)

    Liu, Xiang; Liu, Chang; Hong, Yili

    2017-10-01

    There are annually over two million carloads of hazardous materials transported by rail in the United States. The American railroads use large blocks of tank cars to transport petroleum crude oil and other flammable liquids from production to consumption sites. Being different from roadway transport of hazardous materials, a train accident can potentially result in the derailment and release of multiple tank cars, which may result in significant consequences. The prior literature predominantly assumes that the occurrence of multiple tank car releases in a train accident is a series of independent Bernoulli processes, and thus uses the binomial distribution to estimate the total number of tank car releases given the number of tank cars derailing or damaged. This paper shows that the traditional binomial model can incorrectly estimate multiple tank car release probability by magnitudes in certain circumstances, thereby significantly affecting railroad safety and risk analysis. To bridge this knowledge gap, this paper proposes a novel, alternative Correlated Binomial (CB) model that accounts for the possible correlations of multiple tank car releases in the same train. We test three distinct correlation structures in the CB model, and find that they all outperform the conventional binomial model based on empirical tank car accident data. The analysis shows that considering tank car release correlations would result in a significantly improved fit of the empirical data than otherwise. Consequently, it is prudent to consider alternative modeling techniques when analyzing the probability of multiple tank car releases in railroad accidents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Improved Transient Performance of a Fuzzy Modified Model Reference Adaptive Controller for an Interacting Coupled Tank System Using Real-Coded Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Asan Mohideen Khansadurai

    2014-01-01

    Full Text Available The main objective of the paper is to design a model reference adaptive controller (MRAC with improved transient performance. A modification to the standard direct MRAC called fuzzy modified MRAC (FMRAC is used in the paper. The FMRAC uses a proportional control based Mamdani-type fuzzy logic controller (MFLC to improve the transient performance of a direct MRAC. The paper proposes the application of real-coded genetic algorithm (RGA to tune the membership function parameters of the proposed FMRAC offline so that the transient performance of the FMRAC is improved further. In this study, a GA based modified MRAC (GAMMRAC, an FMRAC, and a GA based FMRAC (GAFMRAC are designed for a coupled tank setup in a hybrid tank process and their transient performances are compared. The results show that the proposed GAFMRAC gives a better transient performance than the GAMMRAC or the FMRAC. It is concluded that the proposed controller can be used to obtain very good transient performance for the control of nonlinear processes.

  11. Rainwater tank drowning.

    Science.gov (United States)

    Byard, Roger W

    2008-11-01

    Drowning remains a significant cause of accidental death in young children. The site of drowning varies among communities and is influenced by cultural and geographic factors, including the availability of particular water sources. The drowning deaths of a twin two-year-old brother and sister in a rainwater tank are reported to demonstrate specific issues that may arise. Ladders, vegetation and trellises may provide access to tanks and should be removed. Secure child-proof access points should also be installed, particularly on in-ground tanks (given the ready accessibility of the latter). As there has been a recent trend in Australia to install more domestic rainwater tanks, the number of childhood rainwater tank drownings and near-drownings will need to be monitored by forensic pathologists and child death review committees to ensure that this has not led to the introduction of a new hazard into the home environment.

  12. Stabilization of in-tank residual wastes and external tank soil contamination for the Hanford tank closure program: application to the AX tank farm

    Energy Technology Data Exchange (ETDEWEB)

    SONNICHSEN, J.C.

    1998-10-12

    Mixed high-level waste is currently stored in underground tanks at the US Department of Energy's (DOE's) Hanford Site. The plan is to retrieve the waste, process the water, and dispose of the waste in a manner that will provide less long-term health risk. The AX Tank Farm has been identified for purposes of demonstration. Not all the waste can be retrieved from the tanks and some waste has leaked from these tanks into the underlying soil. Retrieval of this waste could result in additional leakage. During FY1998, the Sandia National Laboratory was under contract to evaluate concepts for immobilizing the residual waste remaining in tanks and mitigating the migration of contaminants that exist in the soil column. Specifically, the scope of this evaluation included: development of a layered tank fill design for reducing water infiltration; development of in-tank getter technology; mitigation of soil contamination through grouting; sequestering of specific radionuclides in soil; and geochemical and hydrologic modeling of waste-water-soil interactions. A copy of the final report prepared by Sandia National Laboratory is attached.

  13. Numerical study of a magnesium hydride tank

    Science.gov (United States)

    Delhomme, Baptiste; de Rango, Patricia; Marty, Philippe

    2012-11-01

    Hydrogen storage in metal hydride tanks (MHT) is a very promising solution. Several experimental tanks, studied by different teams, have already proved the feasibility and the interesting performances of this solution. However, in much cases, an optimization of tank geometry is still needed in order to perform fast hydrogen loading. The development of efficient numerical tools is a key issue for MHT design and optimization. We propose a simple model representing a metal hydride tank exchanging its heat of reaction with a thermal fluid flow. In this model, the radial and axial discretisations have been decoupled by using Matlab® one-dimensional tools. Calculations are compared to experimental results obtained in a previous study. A good agreement is found for the loading case. The discharging case shows some discrepancies, which are discussed in this paper.

  14. CFD Modeling of the Multipurpose Hydrogen Test Bed (MHTB) Self-Pressurization and Spray Bar Mixing Experiments in Normal Gravity: Effect of the Accommodation Coefficient on the Tank Pressure

    Science.gov (United States)

    Kartuzova, Olga; Kassemi, Mohammad

    2015-01-01

    A CFD model for simulating the self-pressurization of a large scale liquid hydrogen storage tank is utilized in this paper to model the MHTB self-pressurization experiment. The kinetics-based Schrage equation is used to account for the evaporative and condensi ng interfacial mass flows in this model. The effect of the accommodation coefficient for calculating the interfacial mass transfer rate on the tank pressure during tank selfpressurization is studied. The values of the accommodation coefficient which were considered in this study vary from 1.0e-3 to 1.0e-1 for the explicit VOF model and from 1.0e-4 to 1.0e-3 for the implicit VOF model. The ullage pressure evolutions are compared against experimental data. A CFD model for controlling pressure in cryogenic storage tanks by spraying cold liquid into the ullage is also presented. The Euler-Lagrange approach is utilized for tracking the spray droplets and for modeling the interaction between the droplets and the continuous phase (ullage). The spray model is coupled with the VOF model by performing particle tracking in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. Droplet-ullage heat and mass transfer are modeled. The flow, temperature, and interfacial mass flux, as well as droplets trajectories, size distribution and temperatures predicted by the model are presented. The ul lage pressure and vapor temperature evolutions are compared with experimental data obtained from the MHTB spray bar mixing experiment. The effect of the accommodation coefficient for calculating the interfacial and droplet mass transfer rates on the tank pressure during mixing of the vapor using spray is studied. The values used for the accommodation coefficient at the interface vary from 1.0e-5 to 1.0e-2. The droplet accommodation coefficient values vary from 2.0e-6 to 1.0e-4.

  15. Simulation and Analysis of Crashworthiness of Fuel Tank for Helicopters

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Crashworthiness requirement of fuel tanks is one of the important requirements in helicopter designs. The relations among the protection frame, textile layer and rubber layer of the fuel tank are introduced. Two appropriate FE models are established, one is for an uncovered helicopter fuel tank without protection frame, and the other is for fuel tank with protection frame. The dynamic responses of the two types of fuel tanks impinging on the ground with velocities of 17.3 m/s are numerically simulated for the purpose of analyzing energy-absorbing capabilities of the textile layer and protection frame. The feasibility of the current crashworthiness design of the fuel tank is examined though comparing the dynamic response behaviors of the two fuel tanks.

  16. TANK INSPECTION NDE RESULTS FOR FISCAL YEAR 2007INCLUDING WASTE TANKS 35, 36, 37, 38 AND 15

    Energy Technology Data Exchange (ETDEWEB)

    Elder, J

    2007-09-27

    Ultrasonic (UT) nondestructive examinations (NDE) were performed on waste storage tanks 35, 36, 37, 38 and 15 at the Savannah River Site as a part of the 'In-Service Inspection (ISI) Program for High Level Waste Tanks.' 1 The inspections were performed from the annular space of the waste storage tanks. The inspections included thickness mapping and crack detection scans on specified areas of the tanks covering all present and historic interface levels and selected welds with particular emphasis on the vapor space regions. Including the tanks in this report, all of the 27 Type III tanks at SRS have been inspected in accordance with the ISI plan. Of the four Type III tanks examined this year, all had areas of reportable thickness in either the Primary or Secondary tank. All of these areas on the primary tank are attributed to fabrication artifacts. None of the four Type III tanks examined this year showed evidence of service induced thinning on the primary wall. All four tanks had secondary wall and/or floor plates where the remaining thickness measured below the 10% wall loss criteria. Tank 15, a Type II, non-stress relieved, waste tank was also inspected this fiscal year as part of the ISI program. The same examination techniques were used on Tank 15 as on the Type III tanks. Tank 15 has been out of service due to leakage from stress corrosion cracking (SCC). Inspections were performed to validate known corrosion models and determine if crack growth occurred since the previous examination five years ago. Several cracks were found to have increased in length perpendicular to the weld seam. In the areas of the 27 Type III tanks inspected to date, ten tanks have reportable thickness in the primary wall and 17 have reportable thickness in the secondary tank walls or floor. All of the reportable thickness areas in the primary walls are from fabrication artifacts. Incipient pitting has been detected in five of the 27 Type III primary tanks. No cracking was

  17. MODELING OF ION-EXCHANGE FOR CESIUM REMOVAL FROM DISSOLVED SALTCAKE IN SRS TANKS 1-3, 37 AND 41

    Energy Technology Data Exchange (ETDEWEB)

    Smith, F

    2007-08-15

    This report presents an evaluation of the expected performance of engineered Crystalline Silicotitanate (CST) and spherical Resorcinol-Formaldehyde (RF) ion exchange resin for the removal of cesium from dissolved saltcake in SRS Tanks 1-3, 37 and 41. The application presented in this report reflects the expected behavior of engineered CST IE-911 and spherical RF resin manufactured at the intermediate-scale (approximately 100 gallon batch size; batch 5E-370/641). It is generally believed that scale-up to production-scale in RF resin manufacturing will result in similarly behaving resin batches whose chemical selectivity is unaffected while total capacity per gram of resin may vary. As such, the predictions provided within this report should provide reasonable estimates of production-scale column performance. Two versions of the RF cesium isotherm were used. The older version provides a conservative estimate of the resin capacity while the newer version more accurately fits the most recent experimental data.

  18. OPTIMISATION OF MANTLE TANKS FOR LOW FLOW SOLAR HEATING SYSTEMS

    DEFF Research Database (Denmark)

    Shah, Louise Jivan; Furbo, Simon

    1996-01-01

    A model, describing the heat transfer coefficients in the mantle of a mantle tank has been developed. The model is validated by means of measurements with varying operational conditions for different designed mantle tanks. The model has been implemented in an existing detailed mathematical...... programme that simulates the thermal behaviour of low flow SDHW systems. The yearly thermal performance of low flow SDHW systems with different designed mantle tanks has been calculated. The influence of the mantle tank design on the thermal performance is investigated by means of the calculations...... with the programme and by means of tests of three SDHW systems with different designed mantle tanks. Based on the investigations design rules for mantle tanks are proposed. The model, describing the heat transfer coefficients in the mantle is approximate. In addition, the measurements have revealed...

  19. Tank 241-C-203: Tank characterization plan

    Energy Technology Data Exchange (ETDEWEB)

    Schreiber, R.D.

    1995-03-06

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, and WHC 222-S Laboratory. Scope of this plan is to provide guidance for sampling and analysis of samples for tank 241-C-203.

  20. Tank 241-C-204 Tank Characterization Plan

    Energy Technology Data Exchange (ETDEWEB)

    Schreiber, R.D. [Westinghouse Hanford Co., Richland, WA (United States)

    1995-03-06

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, and WHC 222-S Laboratory. Scope of this plan is to provide guidance for sampling and analysis of samples for tank 241-C-204.

  1. Tank 241-SX-115 tank characterization plan

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, L.M.

    1995-04-24

    This document is a plan which serves as the contractual agreement between the Characterization Project, Sampling Operations, and WHC 222-S Laboratory. The scope of this plan is to provide guidance for the sampling and analysis of samples for tank 241-SX-115.

  2. Tank 241-TY-104 Tank characterization plan

    Energy Technology Data Exchange (ETDEWEB)

    Schreiber, R.D. [Westinghouse Hanford Co., Richland, WA (United States)

    1995-02-15

    This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, and WHC 222-C Laboratory. The scope of this plan is to provide guidance for the sampling and analysis of samples for tank 241-TY-104.

  3. Supporting document for the historical tank content estimate for SY-tank farm

    Energy Technology Data Exchange (ETDEWEB)

    Brevick, C.H.

    1997-08-12

    The purpose of this historical characterization document is to present the synthesized summaries of the historical records concerning the physical characteristics, radiological, and chemical composition of mixed wastes stored in underground double-shell tanks and the physical condition of these tanks. The double-shell tanks are located on the United States Department of Energy`s Hanford Site, approximately 25 miles northwest or Richland, Washington. The document will be used to assist in characterizing the waste in the tanks in conjunction with the current program of sampling and analyzing the tank wastes. Los Alamos National Laboratory (LANL) developed computer models that used the historical data to attempt to characterize the wastes and to generate estimates of each tank`s inventory. A historical review of the tanks may reveal anomalies or unusual contents that could be critical to characterization and post characterization activities. This document was developed by reviewing the operating plant process histories, waste transfer data, and available physical and chemical data from numerous resources. These resources were generated by numerous contractors from 1945 to the present. Waste characterization, the process of describing the character or quality of a waste, is required by Federal law (Resource Conservation and Recovery Act [RCRA]) and state law (Washington Administrative Code [WAC] 173-303, Dangerous Waste Regulations). Characterizing the waste is necessary to determine methods to safely retrieve, transport, and/or treat the wastes.

  4. High-Precision Plutonium Isotopic Compositions Measured on Los Alamos National Laboratory’s General’s Tanks Samples: Bearing on Model Ages, Reactor Modelling, and Sources of Material. Further Discussion of Chronometry

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, Khalil J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rim, Jung Ho [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Porterfield, Donivan R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Roback, Robert Clifford [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Boukhalfa, Hakim [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stanley, Floyd E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-06-29

    In this study, we re-analyzed late-1940’s, Manhattan Project era Plutonium-rich sludge samples recovered from the ''General’s Tanks'' located within the nation’s oldest Plutonium processing facility, Technical Area 21. These samples were initially characterized by lower accuracy, and lower precision mass spectrometric techniques. We report here information that was previously not discernable: the two tanks contain isotopically distinct Pu not only for the major (i.e., 240Pu, 239Pu) but trace (238Pu ,241Pu, 242Pu) isotopes. Revised isotopics slightly changed the calculated 241Am-241Pu model ages and interpretations.

  5. 解读TANKED

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    品牌为重、创造为先,Tanked racing用不走“寻常路”给国内众多同行们生动地上了一课。通过持续近四年的高速成长,Tanked racingE成为中国头盔业翘楚,然而Tanked racing并不局限于此,因为未来的舞台还很大。

  6. FAST Model Calibration and Validation of the OC5- DeepCwind Floating Offshore Wind System Against Wave Tank Test Data: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, Fabian F [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Robertson, Amy N [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jonkman, Jason [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-09

    During the course of the Offshore Code Comparison Collaboration, Continued, with Correlation (OC5) project, which focused on the validation of numerical methods through comparison against tank test data, the authors created a numerical FAST model of the 1:50-scale DeepCwind semisubmersible system that was tested at the Maritime Research Institute Netherlands ocean basin in 2013. This paper discusses several model calibration studies that were conducted to identify model adjustments that improve the agreement between the numerical simulations and the experimental test data. These calibration studies cover wind-field-specific parameters (coherence, turbulence), hydrodynamic and aerodynamic modeling approaches, as well as rotor model (blade-pitch and blade-mass imbalances) and tower model (structural tower damping coefficient) adjustments. These calibration studies were conducted based on relatively simple calibration load cases (wave only/wind only). The agreement between the final FAST model and experimental measurements is then assessed based on more-complex combined wind and wave validation cases.

  7. Stress Analysis of Vertical Dome Tank and Influencing Factors Analysis of Weak roof Based on Three -dimensional Model%基于三维模型的立式拱顶储罐应力分析与弱顶影响因素分析

    Institute of Scientific and Technical Information of China (English)

    丁宇奇; 刘巨保; 武铜柱; 张维忠

    2011-01-01

    Researching for 3 × 103 m3 vertical dome tank, according to the weak roof requirement of GB 50341 standard, the weak roof performance of tank was evaluated. Establishing tank space model, u-sing the finite element method for tank stress analysis, stress distribution and intensity breakdown pressure of empty tank, half tank and full tank were calculated. The main factors of weak roof performance of tank are found out, and the possibility of which the tanks are designed into weak roof tanks is discussed through the influencing factors analysis of weak roof.%以3×103 m3立式拱顶储罐为研究对象,针对GB 50341对弱顶结构的要求,评价储罐的弱顶性能.建立储罐的空间模型,采用有限元法对储罐进行应力分析,计算得到储罐在空罐、半罐、满罐下的应力分布和强度破坏压力.通过对储罐弱顶影响因素的分析,找出影响储罐弱顶性能的主要因素,并探讨了使该类储罐设计成弱顶的可能性.

  8. Understanding the transformation, speciation, and hazard potential of copper particles in a model septic tank system using zebrafish to monitor the effluent.

    Science.gov (United States)

    Lin, Sijie; Taylor, Alicia A; Ji, Zhaoxia; Chang, Chong Hyun; Kinsinger, Nichola M; Ueng, William; Walker, Sharon L; Nel, André E

    2015-02-24

    Although copper-containing nanoparticles are used in commercial products such as fungicides and bactericides, we presently do not understand the environmental impact on other organisms that may be inadvertently exposed. In this study, we used the zebrafish embryo as a screening tool to study the potential impact of two nano Cu-based materials, CuPRO and Kocide, in comparison to nanosized and micron-sized Cu and CuO particles in their pristine form (0-10 ppm) as well as following their transformation in an experimental wastewater treatment system. This was accomplished by construction of a modeled domestic septic tank system from which effluents could be retrieved at different stages following particle introduction (10 ppm). The Cu speciation in the effluent was identified as nondissolvable inorganic Cu(H2PO2)2 and nondiffusible organic Cu by X-ray diffraction, inductively coupled plasma mass spectrometry (ICP-MS), diffusive gradients in thin-films (DGT), and Visual MINTEQ software. While the nanoscale materials, including the commercial particles, were clearly more potent (showing 50% hatching interference above 0.5 ppm) than the micron-scale particulates with no effect on hatching up to 10 ppm, the Cu released from the particles in the septic tank underwent transformation into nonbioavailable species that failed to interfere with the function of the zebrafish embryo hatching enzyme. Moreover, we demonstrate that the addition of humic acid, as an organic carbon component, could lead to a dose-dependent decrease in Cu toxicity in our high content zebrafish embryo screening assay. Thus, the use of zebrafish embryo screening, in combination with the effluents obtained from a modeled exposure environment, enables a bioassay approach to follow the change in the speciation and hazard potential of Cu particles instead of difficult-to-perform direct particle tracking.

  9. On Assumptions in Development of a Mathematical Model of Thermo-gravitational Convection in the Large Volume Process Tanks Taking into Account Fermentation

    Directory of Open Access Journals (Sweden)

    P. M. Shkapov

    2015-01-01

    Full Text Available The paper provides a mathematical model of thermo-gravity convection in a large volume vertical cylinder. The heat is removed from the product via the cooling jacket at the top of the cylinder. We suppose that a laminar fluid motion takes place. The model is based on the NavierStokes equation, the equation of heat transfer through the wall, and the heat transfer equation. The peculiarity of the process in large volume tanks was the distribution of the physical parameters of the coordinates that was taken into account when constructing the model. The model corresponds to a process of wort beer fermentation in the cylindrical-conical tanks (CCT. The CCT volume is divided into three zones and for each zone model equations was obtained. The first zone has an annular cross-section and it is limited to the height by the cooling jacket. In this zone the heat flow from the cooling jacket to the product is uppermost. Model equation of the first zone describes the process of heat transfer through the wall and is presented by linear inhomogeneous differential equation in partial derivatives that is solved analytically. For the second and third zones description there was a number of engineering assumptions. The fluid was considered Newtonian, viscous and incompressible. Convective motion considered in the Boussinesq approximation. The effect of viscous dissipation is not considered. The topology of fluid motion is similar to the cylindrical Poiseuille. The second zone model consists of the Navier-Stokes equations in cylindrical coordinates with the introduction of a simplified and the heat equation in the liquid layer. The volume that is occupied by an upward convective flow pertains to the third area. Convective flows do not mix and do not exchange heat. At the start of the process a medium has the same temperature and a zero initial velocity in the whole volume that allows us to specify the initial conditions for the process. The paper shows the

  10. Buoyancy driven flow in a hot water tank due to standby heat loss

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2012-01-01

    show that the CFD model predicts satisfactorily water temperatures at different levels of the tank during cooling by standby heat loss. It is elucidated how the downward buoyancy driven flow along the tank wall is established by the heat loss from the tank sides and how the natural convection flow......Results of experimental and numerical investigations of thermal behavior in a vertical cylindrical hot water tank due to standby heat loss of the tank are presented. The effect of standby heat loss on temperature distribution in the tank is investigated experimentally on a slim 150l tank...... parts of the tank is measured by experiments and used as input to the CFD model. Water temperatures at different levels of the tank are measured and compared to CFD calculated temperatures. The investigations focus on validation of the CFD model and on understanding of the CFD calculations.The results...

  11. Ocean Technology Development Tank

    Data.gov (United States)

    Federal Laboratory Consortium — The new SWFSC laboratory in La Jolla incorporates a large sea- and fresh-water Ocean Technology Development Tank. This world-class facility expands NOAA's ability to...

  12. Sonar Tank Area

    Data.gov (United States)

    Federal Laboratory Consortium — The Sonar Tank Facility permits low cost initial 'wet' testing and check out prior to full scale deployment at sea. It can manage controlled conditions calibration...

  13. Tank waste characterization basis

    Energy Technology Data Exchange (ETDEWEB)

    Brown, T.M.

    1996-08-09

    This document describes the issues requiring characterization information, the process of determining high priority tanks to obtain information, and the outcome of the prioritization process. In addition, this document provides the reasoning for establishing and revising priorities and plans.

  14. TANK 21 AND TANK 24 BLEND AND FEED STUDY: BLENDING TIMES, SETTLING TIMES, AND TRANSFERS

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.; Leishear, R.; Poirier, M.

    2012-05-31

    The Salt Disposition Integration (SDI) portfolio of projects provides the infrastructure within existing Liquid Waste facilities to support the startup and long term operation of the Salt Waste Processing Facility (SWPF). Within SDI, the Blend and Feed Project will equip existing waste tanks in the Tank Farms to serve as Blend Tanks where salt solutions of up to 1.2 million gallons will be blended in 1.3 million gallon tanks and qualified for use as feedstock for SWPF. In particular, Tanks 21 and 24 are planned to be used for blending and transferring to the SDI feed tank. These tanks were evaluated here to determine blending times, to determine a range of settling times for disturbed sludge, and to determine that the SWPF Waste Acceptance Criteria that less than 1200 mg/liter of solids will be entrained in salt solutions during transfers from the Tank 21 and Tank 24 will be met. Overall conclusions for Tank 21 and Tank 24 operations include: (1) Experimental correction factors were applied to CFD (computational fluid dynamics) models to establish blending times between approximately two and five hours. As shown in Phase 2 research, blending times may be as much as ten times greater, or more, if lighter fluids are added to heavier fluids (i.e., water added to salt solution). As the densities of two salt solutions converge this effect may be minimized, but additional confirmatory research was not performed. (2) At the current sludge levels and the presently planned operating heights of the transfer pumps, solids entrainment will be less than 1200 mg/liter, assuming a conservative, slow settling sludge simulant. (3) Based on theoretical calculations, particles in the density range of 2.5 to 5.0 g/mL must be greater than 2-4 {micro}m in diameter to ensure they settle adequately in 30-60 days to meet the SWPF feed criterion (<1200 mg/l). (4) Experimental tests with sludge batch 6 simulant and field turbidity data from a recent Tank 21 mixing evolution suggest the solid

  15. 49 CFR 179.401 - Individual specification requirements applicable to inner tanks for cryogenic liquid tank car tanks.

    Science.gov (United States)

    2010-10-01

    ... to inner tanks for cryogenic liquid tank car tanks. 179.401 Section 179.401 Transportation Other... TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS SPECIFICATIONS FOR TANK CARS Specification for Cryogenic Liquid... requirements applicable to inner tanks for cryogenic liquid tank car tanks. ...

  16. TANK CAR CONSTRUCTION REFINMENT

    Directory of Open Access Journals (Sweden)

    A. N. Soberzhansjkyj

    2010-06-01

    Full Text Available The increase of volume and load-carrying capacity of tank cars is an urgent task for improving the efficiency of transportation of liquid bulk cargoes. Variants of the constructive and technical approaches, which allow increasing the specified indices, are considered. After the analysis the most rational constructive scheme meeting the modern requirements for tank cars and allowing to raise their productivity is chosen.

  17. TANK 5 SAMPLING

    Energy Technology Data Exchange (ETDEWEB)

    Vrettos, N; William Cheng, W; Thomas Nance, T

    2007-11-26

    Tank 5 at the Savannah River Site has been used to store high level waste and is currently undergoing waste removal processes in preparation for tank closure. Samples were taken from two locations to determine the contents in support of Documented Safety Analysis (DSA) development for chemical cleaning. These samples were obtained through the use of the Drop Core Sampler and the Snowbank Sampler developed by the Engineered Equipment & Systems (EES) group of the Savannah River National Laboratory (SRNL).

  18. TANK 5 SAMPLING

    Energy Technology Data Exchange (ETDEWEB)

    Vrettos, N; William Cheng, W; Thomas Nance, T

    2007-11-26

    Tank 5 at the Savannah River Site has been used to store high level waste and is currently undergoing waste removal processes in preparation for tank closure. Samples were taken from two locations to determine the contents in support of Documented Safety Analysis (DSA) development for chemical cleaning. These samples were obtained through the use of the Drop Core Sampler and the Snowbank Sampler developed by the Engineered Equipment & Systems (EES) group of the Savannah River National Laboratory (SRNL).

  19. Results of Experimental Investigations to Determine External Tank Protuberance Loads Using a 0.03-Scale Model of the Space Shuttle Launch Configuration (Model 47-OTS) in the NASA/ARC Unitary Plan Wind Tunnel, Volume 2

    Science.gov (United States)

    Houlihan, S. R.

    1992-01-01

    Data were obtained on a 3-percent model of the Space Shuttle launch vehicle in the NASA/Ames Research Center 11x11-foot and 9x7-foot Unitary Plan Wind Tunnels. This test series has been identified as IA19OA/B and was conducted from 7 Feb. 1980 to 19 Feb. 1980 (IA19OA) and from 17 March 1980 to 19 March 1980 and from 8 May 1980 to 30 May 1980 (IA19OB). The primary test objective was to obtain structural loads on the following external tank protuberances: (1) LO2 feedline; (2) GO2 pressure line; (3) LO2 antigeyser line; (4) GH2 pressure line; (5) LH2 tank cable tray; (6) LO2 tank cable tray; (7) Bipod; (8) ET/SRB cable tray; and (9) Crossbeam/Orbiter cable tray. To fulfill these objectives the following steps were taken: Eight 3-component balances were used to measure forces on various sections of 1 thru 6 above; 315 pressure orifices were distributed over all 9 above items. The LO2 feedline was instrumented with 96 pressure taps and was rotated to four positions to yield 384 pressure measurements. The LO2 antigeyser line was instrumented with 64 pressure taps and was rotated to two positions to yield 128 pressure measurements; Three Chrysler miniature flow direction probes were mounted on a traversing mechanism on the tank upper surface centerline to obtain flow field data between the forward and aft attach structures; and Schlieren photographs and ultraviolet flow photographs were taken at all test conditions. Data from each of the four test phases are presented.

  20. Results of experimental investigations to determine external tank protuberance loads using a 0.03-scale model of the Space Shuttle launch configuration (model 47-OTS) in the NASA/ARC unitary plan wind tunnel, volume 1

    Science.gov (United States)

    Houlihan, S. R.

    1992-01-01

    Data were obtained on a 3-percent model of the Space Shuttle launch vehicle in the NASA/Ames Research Center 11x11-foot and 9x7-foot Unitary Plan Wind Tunnels. This test series has been identified as IA190A/B and was conducted from 7 Feb. 1980 to 19 Feb. 1980 (IA190A) and from 17 March 1980 to 19 March 1980 and from 8 May 1980 to 30 May 1980 (IA190B). The primary test objective was to obtain structural loads on the following external tank protuberances: (1) LO2 feedline, (2) GO2 pressure line, (3) LO2 antigeyser line, (4) GH2 pressure line, (5) LH2 tank cable tray, (6) LO2 tank cable tray, (7) Bipod, (8) ET/SRB cable tray, and (9) Crossbeam/Orbiter cable tray. To fulfill these objectives the following steps were taken: (1) Eight 3-component balances were used to measure forces on various sections of 1 thru 6 above. (2) 315 pressure orifices were distributed over all 9 above items. The LO2 feedline was instrumented with 96 pressure taps and was rotated to four positions to yield 384 pressure measurements. The LO2 antigeyser line was instrumented with 64 pressure taps and was rotated to two positions to yield 128 pressure measurements. (3) Three Chrysler miniature flow direction probes were mounted on a traversing mechanism on the tank upper surface centerline to obtain flow field data between the forward and aft attach structures. (4) Schlieren photographs and ultraviolet flow photographs were taken at all test conditions. Data from each of the four test phases are presented.

  1. AX Tank farm closure settlement estimates and soil testing

    Energy Technology Data Exchange (ETDEWEB)

    BECKER, D.L.

    1999-03-25

    This study provides a conservative three-dimensional settlement study of the AX Tank Farm closure with fill materials and a surface barrier. The finite element settlement model constructed included the interaction of four tanks and the surface barrier with the site soil and bedrock. Also addressed are current soil testing techniques suitable for the site soil with recommendations applicable to the AX Tank Farm and the planned cone penetration testing.

  2. 基于AMESet的压力油箱供油系统建模与仿真研究%Research on Modeling and Simulation of Hydraulic Oil Supply System with Pressurized Tank Based on AMESet

    Institute of Scientific and Technical Information of China (English)

    吕庆军; 杨庆俊; 朱冬

    2013-01-01

    Pressurized tank was used for hydraulic system in armoured vehicle to provide instantaneous high flow for hydraulic brake and to supply hydraulic oil to other branches such as lubricating systems.By mathematically modeling the pneumatic gear pump, hybrid relief valve for both air and oil,and pressurized tank,a complete simulation model for this hydraulic system with pressurized tank as its core element was established based on AMESet,which was easily embedded in the system established by AMESim for simu-lation.The simulation model shows that the model is correct to represent characteristics of the pneumatic pump,hybrid relief valve and the tank,and thus can be used for the optimization design of the pressurized tank.%装甲车辆的供油系统采用压力油箱以提供制动时所需的瞬时大流量液流,同时保证润滑等其他油路的用油。基于AMESet构建了以压力油箱为核心的供油系统仿真模型,对压力油箱中气动齿轮泵、气液混合溢流阀和油箱等子模型进行了数学建模,可以方便地嵌入到AMESim构建的总系统中进行仿真。该仿真模型能够正确仿真压力油箱中气泵、气液混合溢流阀等特性,为压力油箱的优化设计提供了依据。

  3. Double-shell tank remaining useful life estimates

    Energy Technology Data Exchange (ETDEWEB)

    Anantatmula, R.P., Westinghouse Hanford

    1996-12-02

    The existing 28 double-shell tanks (DSTS) at Hanford are currently planned to continue operation through the year 2028 when disposal schedules show removal of waste. This schedule will place the DSTs in a service life window of 4O to 60 years depending on tank construction date and actual retirement date. This paper examines corrosion- related life-limiting conditions of DSTs and reports the results of remaining useful life models developed for estimating remaining tank life. Three models based on controllable parameters such as temperature, chemistry, and relative humidity are presented for estimates to the year in which a particular DST may receive a breach in the primary tank due to pitting in the liquid or vapor region. Pitting is believed to be the life-limiting condition for DSTs,however, the region of the most aggressive pitting (vapor space or liquid) requires further investigation. The results of the models presented suggest none of the existing DSTs should fail by through-wall pitting until well beyond scheduled retrieval in 2028. The estimates of tank breach years (the year in which a tank may be expected to breach the primary tank wall) range from 2056 for pitting corrosion in the liquid region of tank 104-AW to beyond the next millennium for several tanks in the vapor region.

  4. MIXING STUDY FOR JT-71/72 TANKS

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.

    2013-11-26

    All modeling calculations for the mixing operations of miscible fluids contained in HBLine tanks, JT-71/72, were performed by taking a three-dimensional Computational Fluid Dynamics (CFD) approach. The CFD modeling results were benchmarked against the literature results and the previous SRNL test results to validate the model. Final performance calculations were performed by using the validated model to quantify the mixing time for the HB-Line tanks. The mixing study results for the JT-71/72 tanks show that, for the cases modeled, the mixing time required for blending of the tank contents is no more than 35 minutes, which is well below 2.5 hours of recirculation pump operation. Therefore, the results demonstrate the adequacy of 2.5 hours’ mixing time of the tank contents by one recirculation pump to get well mixed.

  5. Simplified Model Research on Framed Spherical Tank Seismic Substructure%支架式球形储罐子结构简化模型

    Institute of Scientific and Technical Information of China (English)

    周利剑; 孙铭阳; 王雪

    2016-01-01

    近些年,地震的发生频率呈现上升趋势,而抗震研究的重要性也日益提高。作为新兴的抗震试验方法——子结构振动台试验方法,也日趋被人们所重视。采用4种方法对支架式球形储罐进行模态分析,得到合理的简化全模型。在全模型基础上进行子结构简化模型划分求解,对比分析出从结构下两层处划分结构为最合理的子结构简化模型形式。在支架式储罐子结构研究中,把下两层支架部分作为试验子结构,将整体划分成双质点体系进行后续抗震性能试验研究。%In recent years, the frequency that the earthquakes occur shows a tendency of raising, and the importance of the seismic method is increasing gradually. As a new seismic experiment method, substructure shaking table experiment method becomes attention by people increasingly. This paper takes four methods to carry out the modal analysis of the framed spherical storage tank and get a reasonable simplified model. By deciding and solving the simplified model of the substructure on the basis of the whole model,it came to the con-clusion that most reasonable simplified model form of substructure is that dividing the structure from the two layers of the structure. In the research of the substructure about the framed spherical tank, treat the two layers of the structure as test substructure, and the whole struc-ture regard as two particle system experiments were carried out to study the seismic perfor-mance of the following.

  6. Computational Analyses of Pressurization in Cryogenic Tanks

    Science.gov (United States)

    Ahuja, Vineet; Hosangadi, Ashvin; Lee, Chun P.; Field, Robert E.; Ryan, Harry

    2010-01-01

    A comprehensive numerical framework utilizing multi-element unstructured CFD and rigorous real fluid property routines has been developed to carry out analyses of propellant tank and delivery systems at NASA SSC. Traditionally CFD modeling of pressurization and mixing in cryogenic tanks has been difficult primarily because the fluids in the tank co-exist in different sub-critical and supercritical states with largely varying properties that have to be accurately accounted for in order to predict the correct mixing and phase change between the ullage and the propellant. For example, during tank pressurization under some circumstances, rapid mixing of relatively warm pressurant gas with cryogenic propellant can lead to rapid densification of the gas and loss of pressure in the tank. This phenomenon can cause serious problems during testing because of the resulting decrease in propellant flow rate. With proper physical models implemented, CFD can model the coupling between the propellant and pressurant including heat transfer and phase change effects and accurately capture the complex physics in the evolving flowfields. This holds the promise of allowing the specification of operational conditions and procedures that could minimize the undesirable mixing and heat transfer inherent in propellant tank operation. In our modeling framework, we incorporated two different approaches to real fluids modeling: (a) the first approach is based on the HBMS model developed by Hirschfelder, Beuler, McGee and Sutton and (b) the second approach is based on a cubic equation of state developed by Soave, Redlich and Kwong (SRK). Both approaches cover fluid properties and property variation spanning sub-critical gas and liquid states as well as the supercritical states. Both models were rigorously tested and properties for common fluids such as oxygen, nitrogen, hydrogen etc were compared against NIST data in both the sub-critical as well as supercritical regimes.

  7. Material selection for Multi-Function Waste Tank Facility tanks

    Energy Technology Data Exchange (ETDEWEB)

    Larrick, A.P.; Blackburn, L.D.; Brehm, W.F.; Carlos, W.C.; Hauptmann, J.P. [Westinghouse Hanford Co., Richland, WA (United States); Danielson, M.J.; Westerman, R.E. [Pacific Northwest Lab., Richland, WA (United States); Divine, J.R. [ChemMet Ltd., West Richland, WA (United States); Foster, G.M. [ICF Kaiser Hanford Co., Richland, WA (United States)

    1995-03-01

    This paper briefly summarizes the history of the materials selection for the US Department of Energy`s high-level waste carbon steel storage tanks. It also provides an evaluation of the materials for the construction of new tanks at the evaluation of the materials for the construction of new tanks at the Multi-Function Waste Tank Facility. The evaluation included a materials matrix that summarized the critical design, fabrication, construction, and corrosion resistance requirements: assessed. each requirement: and cataloged the advantages and disadvantages of each material. This evaluation is based on the mission of the Multi-Function Waste Tank Facility. On the basis of the compositions of the wastes stored in Hanford waste tanks, it is recommended that tanks for the Multi-Function Waste Tank Facility be constructed of ASME SA 515, Grade 70, carbon steel.

  8. Topographical Mapping System. Tanks Focus Area. OST Reference # 130

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    1999-09-01

    Radioactive waste storage tanks in use at many of the U.S. Department of Energy (DOE) sites are beyond the intended design life. The waste in these tanks must be remediated and the tanks closed. Before these activities are performed, the physical condition of tank interiors must be determined along with detailed information regarding any obstructions and potential problems that may be encountered during installation of retrieval systems. This task is difficult because the tanks are underground and have limited access. The only way to see the physical contents of the tank is to install tools through the tank’s openings, or risers. The Topographical Mapping System (TMS), a three-dimensional (3-D) mapping system that can safely operate in hazardous and radiological environments, has been developed to meet this need. This system provides an accurate 3-D view of the tank interior and gathers data on volume and contents inside storage tanks. How It Works: TMS is self-contained and reconfigurable system capable of providing rapid, variable-resolution mapping information in poorly characterized workspaces with a minimum of operator intervention. TMS uses structured light to create maps of waste topography and tank structures, determine surface features and deviations, model the tank environment, and determine residual tank waste volume. The system gathers and analyzes data to generate 3-D maps. The data can be used on a stand-alone basis or integrated with other modeling software to generate “world models” of tanks or other work environments. Figure 1 is a time-lapse photograph of the contour lines that result when the laser planes intersect with the mapped surface. The simulated waste surface in the photograph contains sand, simulated saltcake (white rock), and two black vertical pipes.

  9. TRANSIENT HEAT TRANSFER ANALYSIS FOR SRS RADIOACTIVE TANK OPERATION

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.

    2013-06-27

    The primary objective of the present work is to perform a heat balance study for type-I waste tank to assess the impact of using submersible mixer pumps during waste removal. The temperature results calculated by the model will be used to evaluate the temperatures of the slurry waste under various tank operating conditions. A parametric approach was taken to develop a transient model for the heat balance study for type-I waste tanks such as Tank 11, during waste removal by SMP. The tank domain used in the present model consists of two SMP's for sludge mixing, one STP for the waste removal, cooling coil system with 36 coils, and purge gas system. The sludge waste contained in Tank 11 also has a decay heat load of about 43 W/m{sup 3} mainly due to the emission of radioactive gamma rays. All governing equations were established by an overall energy balance for the tank domain, and they were numerically solved. A transient heat balance model used single waste temperature model, which represents one temperature for the entire waste liquid domain contained in the tank at each transient time.

  10. Dwelling Water Tanks in Diyarbakir

    Directory of Open Access Journals (Sweden)

    Ali Ceylan

    2008-02-01

    Full Text Available BACKGROUND: In this connection, the object of this study has been to identify and compare the microbiological contamination and residue chlorine levels in the main network water that is taken from the Dicle Dam and distributed in Diyarbakir Province Centre and in the tanks of dwellings that use this water as well as the effects of the maintenance, hygiene, and physical conditions of these tanks on microbiological contamination. METHODS: Water samples were taken from both the tank input side network water and tank output side tank waters of 200 dwellings with water tanks in Diyarbakir city centre (tank entrance network side water for 200 and tank output side tank water for 200 within the framework of the research study. RESULTS: Coliform bacteria were detected in 35% of the tank entrance side network water samples and in 52.0% percent of the tank output side water samples. Faecal coliform bacteria were not detected in tank entrance side network water samples, but they existed in 2.5% of the tank output side water samples. Free residue chlorine level was found to be over 0.2 ppm in 67% of tank entrance side network water samples and in 35% of the tank output side water samples. Coliform bacteria were detected in 95.5% of the tank entrance side network water samples, of which free residue chlorine level were below 0.2 ppm. Total germ growth was detected in 52.0% of the tank entrance side network water samples and in 67.5% of the tank output side water samples. The most frequently isolated bacteria both in tank entrance side network and tank output side water samples were found to be Bacillus spp. Bacillus type bacteria were found in 48% of tank entrance side network water samples and 57.5% of the tank output side water samples. Filamentous fungi were prevalent in 8% of all the samples examined within the study and the most commonly isolated filamentous fungi were Aspergillus spp (5.5% and Penicillum spp (2.5%. Water tanks of dwellings contain more

  11. TANK SPACE OPTIONS REPORT

    Energy Technology Data Exchange (ETDEWEB)

    WILLIS WL; AHRENDT MR

    2009-08-11

    Since this report was originally issued in 2001, several options proposed for increasing double-shell tank (DST) storage space were implemented or are in the process of implementation. Changes to the single-shell tank (SST) waste retrieval schedule, completion of DST space saving options, and the DST space saving options in progress have delayed the projected shortfall of DST storage space from the 2007-2011 to the 2018-2025 timeframe (ORP-11242, River Protection Project System Plan). This report reevaluates options from Rev. 0 and includes evaluations of new options for alleviating projected restrictions on SST waste retrieval beginning in 2018 because of the lack of DST storage space.

  12. CFD simulation in emptying tanks for calculating submergence in the case of storage tanks, the CFD simulation is based on the modeling of the suction nozzle which affects the study and final part of the storage tank; Aplicacion de simulacion CFD en el analisis del vaciado de tanques de almacenamiento para determinacion del nivel de sumergencia

    Energy Technology Data Exchange (ETDEWEB)

    Arranz Iglesias, J.; Gavilan Moreno, C.; Sarti Fernandez, F.

    2014-07-01

    The study consists in simulating the emptying of the tank when the water level is near the level of the suction nozzle. The objective pursued is to detect the harmful phenomena that may occur in aspiration, ranging from the appearance of vortices and bubble formation to excessive fluid accelerations. (Author)

  13. Reactor models for a series of continuous stirred tank reactors with a gas-liquid-solid leaching system: Part I. Surface reaction control

    Science.gov (United States)

    Papangelakis, V. G.; Demopoulos, G. P.

    1992-12-01

    In this three-part series of articles, comprehensive three-phase steady-state hydrometallurgical reactor models of the continuous stirred tank reactor (CSTR) type are developed and applied to a commercial (pressure oxidation) process. The key features of the developed models are the coupling of both mass and heat balance equations, the description of the nonisothermal performance (autothermal) of a multistage continuous reactor, and the treatment of multimineral feed materials. The model considers only the oxidation reactions, because they mainly affect the thermal balance of the reactor. The stoichiometries and intrinsic kinetics of the heterogeneous leaching reactions, which are established via independent experiments, are the foundation of the developed model. A three-phase (g-l-s) reaction process might be controlled by either surface reaction control, i.e., the rate(s) of the heterogeneous leaching reaction(s), or by gas transfer control, i.e., the rate of transfer of the gaseous reactant into the liquid phase. In the present article (Part I), the case of surface reaction control is treated. The article addresses, in particular, the following topics: (1) it outlines the basic mass and heat balance equations which describe the performance of a multistage leaching reactor; (2) it presents a continuous function to describe the particle size distribution of the feed; and (3) it develops, on the basis of probability theory, number- and mass-particle size density functions which give the size distribution of particle populations reacting according to the surface reaction control-shrinking core model.

  14. Seismic analysis of a sodium-filled tank

    Energy Technology Data Exchange (ETDEWEB)

    Chen, W.W.

    1990-12-01

    An analysis is described to determine the seismically-induced hydrodynamic responses such as sloshing natural frequency, sloshing pressure, and impulse pressure for a top-supported sodium-filled cylindrical tank. The vibrational effects of an internally immersed pipe on the fluid responses also are considered. Reaction forces from both low frequency fluid modes and high frequency tank modes are combined to determine the required tank support loads. Results from the analysis of the sodium-filled tank model have been compared with the results using the same three-dimensional (3-D) model with lumped fluid mass at evenly distributed shell nodes. The results from the lumped-mass model gave conservative support loads. The analysis used the ANSYS finite-element computer code. The results of the analyses indicate that no sodium sloshing modes exist that may interact with the shell mode. Both the immersed pipe and the tank shell behave in the rigid frequency range.

  15. Improved Polyurethane Storage Tank Performance

    Science.gov (United States)

    2014-06-30

    Figure 5.2.4 – Teen / Twenty Berm Bays from Tank 11 Corner Improved Polyurethane Storage Tank Performance Page 63 of 197 FY2009 Final Technical...5.3.9 Pump Discharge Pressure Measurement Improved Polyurethane Storage Tank Performance Page 76 of 197 FY2009 Final Technical Report...chamber pressure Improved Polyurethane Storage Tank Performance Page 173 of 197 FY2009 Final Technical Report Seaman Corporation could not be

  16. Simplified mechanical model for vibration isolation analysis of a vertical storage tank considering swinging effect%考虑摆动效应的立式储罐隔震分析简化力学模型

    Institute of Scientific and Technical Information of China (English)

    孙建刚; 郝进锋; 刘扬; 王振; 崔利富

    2016-01-01

    对于基础隔震大型立式储罐的地震响应分析问题,考虑土壤与结构的相互作用和储罐的摆动效应,从流体速度势理论出发,结合储罐储液与罐壁的边界条件,建立液体运动势函数和相应的基底剪力、倾覆力矩及波高的理论表达式;并依据剪力和弯矩等效的原理,建立了具有摆动效应的基础隔震储罐的力学简化模型,利用能量原理建立了考虑摆动效应的立式储罐隔震体系的运动方程。同时,以15万 m3大型储罐为例,进行了减震效应数值计算分析,并与无摆动效应的隔震体系的简化力学模型进行了比较分析。结果表明:大型储罐采用基底隔震装置,可以有效地降低储罐的基底剪力,对液体晃动波高的控制效果较差,建议在高烈度区,满足晃动波高的前提下,储罐上部结构可以降低烈度进行设计。%For seismic response analysis of large vertical storage tanks with base isolation,the interaction of soil and structure and the swinging effect of storage tank were considered.Starting from the theory of fluid velocity potential, the boundary conditions of storage tank,storage liquid and tank wall were combined,liquid movement potential function and the corresponding theoretical expressions of base shear,overturning moment and wave height were established. According to the equivalent principle of shear and moment,the simplified mechanical model of a base-isolated tank with swinging effect was established,the motion equation of a vertical storage tank vibration isolation system considering swinging effect was established using the energy principle.At the same time,taking a 15 000 m3 large scale storage tank as an example,the vibration isolation effect numerical analysis was performed,and the comparative analysis between the simplified mechanical model of the system and that of the same system without swinging effect was conducted.The results showed that the

  17. Seismic Vibration Control of Elevated Water Tank by TLD and Validation of Full-Scale TLD Model through Real-Time-Hybrid-Testing

    Science.gov (United States)

    Roy, A.; Staino, A.; (D Ghosh, A.; Basu, B.; Chatterjee, S.

    2016-09-01

    Elevated water tanks (EWTs), being top-heavy structures, are highly vulnerable to earthquake forces, and several have experienced damage/failure in past seismic events. However, as these are critical facilities whose continued performance in the post-earthquake scenario is of vital concern, it is significant to investigate their seismic vibration control using reliable and cost-effective passive dampers such as the Tuned Liquid Damper (TLD). Here, this aspect is studied for flexible EWT structures, such as those with annular shaft supports. The criterion of tuning the sloshing frequency of the TLD to the structural frequency necessitates dimensions of the TLD larger than those hitherto examined in literature. Hence the nonlinear model of the TLD based on established shallow water wave theory is verified for large container size by employing Real-Time-Hybrid-Testing (RTHT). Simulation studies are further carried out on a realistic example of a flexible EWT structure with TLDs. Results indicate that the TLD can be applied very effectively for the seismic vibration mitigation of EWTs.

  18. Dynamic bioconversion mathematical modelling and simulation of urban organic waste co-digestion in continuously stirred tank reactor

    DEFF Research Database (Denmark)

    Fitamo, Temesgen Mathewos; Boldrin, Alessio; Dorini, G.

    waste. However, the successful operation of AD processes is challenged by economic and technological issues. To overcome these barriers, mathematical modelling of the bioconversion process can provide support to develop strategies for controlling and optimizing the AD process. The objective......The application of anaerobic digestion (AD) as process technology is increasing worldwide: the production of biogas, a versatile form of renewable energy, from biomass and organic waste materials allows mitigating greenhouse gas emission from the energy and transportation sectors while treating...... (55 oC). Sludge, food waste, grass clippings, garden waste were co-digested with VS-based mixing ratios of 10:67.5:15.75:6.75 and 10:45:31.5:13.5 in R1 and R2 respectively. The BioModel (Angelidaki et al., 1999) was then employed with minor modifications of model parameters. The model outputs were...

  19. Tank-Treading of Erythrocytes in Strong Shear Flows via a Nonstiff Cytoskeleton-Based Continuum Computational Modeling

    OpenAIRE

    Dodson, W. R.; Dimitrakopoulos, P.

    2010-01-01

    We develop a computationally efficient cytoskeleton-based continuum erythrocyte algorithm. The cytoskeleton is modeled as a two-dimensional elastic solid with comparable shearing and area-dilatation resistance that follows a material law (Skalak, R., A. Tozeren, R. P. Zarda, and S. Chien. 1973. Strain energy function of red blood cell membranes. Biophys. J. 13:245–264). Our modeling enforces the global area-incompressibility of the spectrin skeleton (being enclosed beneath the lipid bilayer i...

  20. USE OF AN EQUILIBRIUM MODEL TO FORECAST DISSOLUTION EFFECTIVENESS, SAFETY IMPACTS, AND DOWNSTREAM PROCESSABILITY FROM OXALIC ACID AIDED SLUDGE REMOVAL IN SAVANNAH RIVER SITE HIGH LEVEL WASTE TANKS 1-15

    Energy Technology Data Exchange (ETDEWEB)

    KETUSKY, EDWARD

    2005-10-31

    This thesis details a graduate research effort written to fulfill the Magister of Technologiae in Chemical Engineering requirements at the University of South Africa. The research evaluates the ability of equilibrium based software to forecast dissolution, evaluate safety impacts, and determine downstream processability changes associated with using oxalic acid solutions to dissolve sludge heels in Savannah River Site High Level Waste (HLW) Tanks 1-15. First, a dissolution model is constructed and validated. Coupled with a model, a material balance determines the fate of hypothetical worst-case sludge in the treatment and neutralization tanks during each chemical adjustment. Although sludge is dissolved, after neutralization more is created within HLW. An energy balance determines overpressurization and overheating to be unlikely. Corrosion induced hydrogen may overwhelm the purge ventilation. Limiting the heel volume treated/acid added and processing the solids through vitrification is preferred and should not significantly increase the number of glass canisters.

  1. Interpreting hydrodynamic behaviour by the model of stirred tanks in series with exchanged zones: preliminary study in lab-scale trickling filters.

    Science.gov (United States)

    Zeng, Ming; Soric, Audrey; Ferrasse, Jean-Henry; Roche, Nicolas

    2013-01-01

    In trickling filters for wastewater treatment, hydrodynamic behaviour is affected by the growth of biofilm on the porous medium. Therefore, modelling hydrodynamic behaviour is necessary and efficient to predict the biodegradation of pollutants. In this study, laboratory-scale trickling filters were filled with two different porous media (glass beads and plastic rings) and were fed by a synthetic substrate in batch mode. Total organic carbon (TOC) of the effluent was measured and retention time distribution (RTD) was determined by injecting NaCl. Results showed that medium had no significant effect on TOC removal rate (around 80% and 60% respectively for batch time of seven and two days). However, regarding the hydrodynamic behaviour, the effective volume ratio and hydraulic efficiency in the glass beads bed increased remarkably from 28% and 18% to 80% and 70%, respectively, with the reduction of dispersion coefficient (from 4.55 to 1.53). Moreover, the short batch time accelerated this change. Conversely, no variation of hydrodynamic behaviour in plastic rings bed was evident. Along with the feeding of synthetic substrate, biofilm concentration ranged from 1.5 to 10.1 g/L in the glass beads reactor and it achieved around 2.8 g/L in the plastic rings reactor. Hydrodynamic modelling indicated that the model of stirred tanks in series with exchanged zones fitted the experimental results well. These gave values of mobile and immobile volumes of 51 mL and 17 mL, respectively, in the glass beads filter and 25 mL and 15 mL, respectively, in the plastic rings filter.

  2. In-Tank Elutriation Test Report And Independent Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Burns, H. H.; Adamson, D. J.; Qureshi, Z. H.; Steeper, T. J.

    2011-04-13

    grown in size over a period of decades. 2. The radionuclides were apparently either in the form of soluble compounds, like cesium, or micrometer sized particles of actinide oxides or hydroxides. 3. After the initial tank retrieval the tank contained cobble which is not conducive to elutriation. Only after the tank contents were treated with thousands of gallons of 50 wt% caustic, were the solids converted to sand which is compatible with elutriation. Discussions between SRNL and PNNL resulted in plans to test elutriation in two phases; in Phase 1 particles would be separated by differences in settling velocity in an existing scaled tank with its associated hardware and in Phase 2 additional hardware, such as a hydrocyclone, would be added downstream to separate slow settling partciels from liquid. Phase 1 of in-tank elutriation was tested for Proof of Principle in theEngineering Development Laboratory of SRNL in a 41" diameter, 87 gallon tank. The tank had been previously used as a 1/22 scale model of Hanford Waste Tank AY-102. The objective of the testing was to determine which tank operating parameters achieved the best separation between fast- and slow-settling particles. For Phase 1 testing a simulated waste tank supernatant, slow-settling particles and fast-settling particles were loaded to the scaled tank. Because this was a Proof of Principle test, readily available solids particles were used that represented fast-settling and slow-settling particles. The tank contents were agitated using rotating mixer jet pumps (MJP) which suspended solids while liquids and solids were drawn out of the tank with a suction tube. The goal was to determine the optimum hydraulic operating conditions to achieve clean separation in which the residual solids in the tank were nearly all fast-settling particles and the solids transferred out of the tank were nearly all slow-settling particles. Tests were conducted at different pump jet velocities, suction tube diameters and suction tube

  3. Seismic Analysis of Reinforced Concrete Shaft Support Water Storage Tank

    Directory of Open Access Journals (Sweden)

    Bharti Tekwani

    2016-05-01

    Full Text Available This paper compares the results of Seismic Analysis of Reinforced Concrete Shaft Support Water Storage Tank carried out in accordance with IS: 1893- 1984 and IS: 1893-2002 (Part-2 draft code. The analysis is carried out for shaft supported water tank of 500,750 and 1000 Cu.m capacity, located in four seismic zones (Zone-II, Zone -III, Zone-IV, Zone-V and on three different soil types (Hard rock, Medium soil, Soft soil. Further, 1000 kl tank for conditions - tank full, tank empty are also considered in this study. The analysis was performed using MAT LAB. The parameters of comparison include base shears, base moments and time history analysis. The above models are analyzed for different time history data such as El Centro, Kobe, Ji-Ji, Erzincan. The comparison is made between the structural responses of one mass and two mass models of above capacity.

  4. Steady State Flammable Gas Release Rate Calculation and Lower Flammability Level Evaluation for Hanford Tank Waste

    Energy Technology Data Exchange (ETDEWEB)

    HU, T.A.

    2000-04-27

    This work is to assess the steady-state flammability level at normal and off-normal ventilation conditions in the tank dome space for 177 double-shell and single-shell tanks at Hanford. Hydrogen generation rate was calculated for 177 tanks using rate equation model developed recently.

  5. ANALYSIS OF TURBULENT MIXING JETS IN LARGE SCALE TANK

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S; Richard Dimenna, R; Robert Leishear, R; David Stefanko, D

    2007-03-28

    Flow evolution models were developed to evaluate the performance of the new advanced design mixer pump for sludge mixing and removal operations with high-velocity liquid jets in one of the large-scale Savannah River Site waste tanks, Tank 18. This paper describes the computational model, the flow measurements used to provide validation data in the region far from the jet nozzle, the extension of the computational results to real tank conditions through the use of existing sludge suspension data, and finally, the sludge removal results from actual Tank 18 operations. A computational fluid dynamics approach was used to simulate the sludge removal operations. The models employed a three-dimensional representation of the tank with a two-equation turbulence model. Both the computational approach and the models were validated with onsite test data reported here and literature data. The model was then extended to actual conditions in Tank 18 through a velocity criterion to predict the ability of the new pump design to suspend settled sludge. A qualitative comparison with sludge removal operations in Tank 18 showed a reasonably good comparison with final results subject to significant uncertainties in actual sludge properties.

  6. Do Fish Enhance Tank Mixing?

    DEFF Research Database (Denmark)

    Rasmussen, Michael R.; Laursen, Jesper; Craig, Steven R.

    2005-01-01

    The design of fish rearing tanks represents a critical stage in the development of optimal aquaculture systems, especially in the context of recirculating systems. Poor hydrodynamics can compromise water quality, waste management and the physiology and behaviour of fish, and thence, production...... potential and operational profitability. The hydrodynamic performance of tanks, therefore, represents an important parameter during the tank design process. Because there are significant complexities in combining the rigid principles of hydrodynamics with the stochastic behaviour of fish, however, most data...... upon tank hydrokinetics has been derived using tanks void of fish. Clearly, the presence of randomly moving objects, such as fish, in a water column will influence not only tank volumes by displacing water, but due to their activity, water dynamics and associated in-tank processes. In order...

  7. 27 CFR 25.145 - Tanks, vehicles, and vessels.

    Science.gov (United States)

    2010-04-01

    ... BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Marks, Brands, and Labels § 25.145 Tanks, vehicles, and... mark each tank, tank car, tank truck, tank ship, barge, or deep tank of a vessel in accordance...

  8. Modeling of Mycobacterium avium subsp. paratuberculosis in farm bulk tank milk

    DEFF Research Database (Denmark)

    Okura, Hisako; Nielsen, Søren Saxmose; Toft, Nils

    2012-01-01

    Mycobacterium avium subsp. paratuberculosis (MAP) in milk of bovine origin is suspected of being implicated Crohn’s disease in humans. Pasteurization is considered to reduce the concentration of MAP by at least 4 to 5 log10. This study aimed at estimating the level of MAP in milk at farm level...... super-shedders. At the prevalence of 15%, discarding milk from test positive cows would result in discarding 11% of milk and reduce the MAP level by 80%. The model was relatively simple yet capable of capturing true infection status and associated contributions from milk and feces. Further knowledge...

  9. Analysis of vadose zone tritium transport from an underground storage tank release using numerical modeling and geostatistics

    Energy Technology Data Exchange (ETDEWEB)

    Lee, K.H.

    1997-09-01

    Numerical and geostatistical analyses show that the artificial smoothing effect of kriging removes high permeability flow paths from hydrogeologic data sets, reducing simulated contaminant transport rates in heterogeneous vadose zone systems. therefore, kriging alone is not recommended for estimating the spatial distribution of soil hydraulic properties for contaminant transport analysis at vadose zone sites. Vadose zone transport if modeled more effectively by combining kriging with stochastic simulation to better represent the high degree of spatial variability usually found in the hydraulic properties of field soils. However, kriging is a viable technique for estimating the initial mass distribution of contaminants in the subsurface.

  10. Overview of Hanford Single Shell Tank (SST) Structural Integrity

    Energy Technology Data Exchange (ETDEWEB)

    Rast, Richard S.; Washenfelder, Dennis J.; Johnson, Jeremy M.

    2013-11-14

    To improve the understanding of the single-shell tanks (SSTs) integrity, Washington River Protection Solutions, LLC (WRPS), the USDOE Hanford Site tank contractor, developed an enhanced Single-Shell Tank Integrity Project (SSTIP) in 2009. An expert panel on SST integrity, consisting of various subject matters experts in industry and academia, was created to provide recommendations supporting the development of the project. This panel developed 33 recommendations in four main areas of interest: structural integrity, liner degradation, leak integrity and prevention, and mitigation of contamination migration, Seventeen of these recommendations were used to develop the basis for the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order, which is also known as the Tri-Party Agreement. The structural integrity of the tanks is a key element in completing the cleanup mission at the Hanford Site. There are eight primary recommendations related to the structural integrity of Hanford Single-Shell Tanks. Six recommendations are being implemented through current and planned activities. The structural integrity of the Hanford is being evaluated through analysis, monitoring, inspection, materials testing, and construction document review. Structural evaluation in the form of analysis is performed using modern finite element models generated in ANSYS. The analyses consider in-situ, thermal, operating loads and natural phenomena such as earthquakes. Structural analysis of 108 of 149 Hanford Single-Shell Tanks has concluded that the tanks are structurally sound and meet current industry standards. Analysis of the remaining Hanford Single-Shell Tanks is scheduled for FY2014. Hanford Single-Shell Tanks are monitored through a dome deflection program. The program looks for deflections of the tank dome greater than 1/4 inch. No such deflections have been recorded. The tanks are also subjected to visual inspection. Digital cameras record the interior surface of

  11. Study of Heat Transfer in Ice-storage Tank

    Institute of Scientific and Technical Information of China (English)

    Anding He; Huanqun Qian; Zhihua Hu; Fangde Zhou

    2001-01-01

    The heat transfer process of ice formation on the outside of coil pipe in the ice storage tank with glycol solution as the second refrigerant was studied in this paper analytically and experimentally. A model was developed for the charging process and the conduction shape factor was applied. Also, the result obtained from the model was compared with the experimental data, both data were in agreement. The simple model is useful for the operation, design and optimization of the ice storage tank.

  12. Two-Phase Flow in Circular Secondary Sedimentation Tanks

    OpenAIRE

    Matko, T. I. R.

    1997-01-01

    The main objective of this work was to optimise a numerical model to predict the flow in circular secondary sedimentation tanks. The numerical models in the literature were reviewed and the new opportunities for research were identified. Single-phase flow characteristics of two circular sedimentation tanks were investigated using the CFD program, CFX-F3D. The flow in the circular clarifiers were modelled in two dimensions (axial and radial) and using the standard k-E turbule...

  13. Numerical modeling method on the movement of water flow and suspended solids in two-dimensional sedimentation tanks in the wastewater treatment plant

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Taking the distributing calculation of velocity and concentration as an example, the paper established a series of governing equations by the vorticity-stream function method, and dispersed the equations by the finite differencing method. After figuring out the distribution field of velocity, the paper also calculated the concentration distribution in sedimentation tank by using the two-dimensional concentration transport equation. The validity and feasibility of the numerical method was verified through comparing with experimental data. Furthermore, the paper carried out a tentative exploration into the application of numerical simulation of sedimentation tanks.

  14. Hydroxide depletion in dilute supernates stored in waste tanks

    Energy Technology Data Exchange (ETDEWEB)

    Hobbs, D.T.

    1985-10-10

    Free hydroxide ion in dilute supernates are depleted by reaction with atmospheric carbon dioxide to form bicarbonate and carbonate species and by reaction with acidic compounds formed by the radiolytic decomposition of tetraphenylborate salts. A model of the kinetics and thermodynamics of absorption of carbon dioxide in the waste tanks has been developed. Forecasts of the rate of hydroxide depletion and the requirements for sodium hydroxide to maintain technical standards have been made for the washed sludge and washed precipitate storage tanks. Hydroxide depletion is predicted to have a minimal impact on sludge processing operations. However, in-tank precipitation and downstream DWPF operations are predicted to be significantly affected by hydroxide depletion in Tank 49H. The installation of a carbon dioxide scrubber on Tank 49H may be justified in view of the decrease in alkali content and variation in the melter feed.

  15. 航空液压油箱密封结构的改进及可靠性建模分析%Improvement and Reliability Modeling Analysis of Aviation Hydraulic Oil Tank Sealing Structure

    Institute of Scientific and Technical Information of China (English)

    焦留芳; 鲁兴红

    2015-01-01

    为提高航空液压油箱使用寿命,通过分析某液压油箱的密封结构,指出液压油箱中比较关键或容易出现问题的密封结构,并进行一系列改进。根据密封件的失效机制及失效原因,通过对失效条件进行组合、简化,建立密封结构可靠性分析模型,评估密封改进方案的可行性。航空液压油箱寿命试验和实际应用均验证了可靠性模型的正确性。密封件的可靠性建模分析方法,可用于液压油箱密封方案设计、设计方案评估、故障分析等。%In order to improve the service life of a aviation hydraulic oil tank,its sealing structure was analyzed. The sealing structures of the hydraulic tank which are key or prone to problems were pointed out,and a series of improvements were performed.According to the failure mechanism and the failure reason of the seal,the reliability analysis model of the sealing structure was established through combining and simplifying the failure conditions,and the feasibility of the seal improvement scheme was evaluated.The correctness of the reliability model was verified by the life tests and the practical application of aviation hydraulic tank. The reliability analysis method of the seal parts can be used for the design of the sealing scheme,the design scheme and the fault analysis of the hydraulic oil tank.

  16. HYDRAULICS AND MIXING EVALUATIONS FOR NT-21/41 TANKS

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.; Barnes, O.

    2014-11-17

    The hydraulic results demonstrate that pump head pressure of 20 psi recirculates about 5.6 liters/min flowrate through the existing 0.131-inch orifice when a valve connected to NT-41 is closed. In case of the valve open to NT-41, the solution flowrates to HB-Line tanks, NT-21 and NT-41, are found to be about 0.5 lpm and 5.2 lpm, respectively. The modeling calculations for the mixing operations of miscible fluids contained in the HB-Line tank NT-21 were performed by taking a three-dimensional Computational Fluid Dynamics (CFD) approach. The CFD modeling results were benchmarked against the literature results and the previous SRNL test results to validate the model. Final performance calculations were performed for the nominal case by using the validated model to quantify the mixing time for the HB-Line tank. The results demonstrate that when a pump recirculates a solution volume of 5.7 liters every minute out of the 72-liter tank contents containing two acid solutions of 2.7 M and 0 M concentrations (i.e., water), a minimum mixing time of 1.5 hours is adequate for the tank contents to get the tank contents adequately mixed. In addition, the sensitivity results for the tank contents of 8 M existing solution and 1.5 M incoming species show that the mixing time takes about 2 hours to get the solutions mixed.

  17. Glass Bubbles Insulation for Liquid Hydrogen Storage Tanks

    Science.gov (United States)

    Sass, J. P.; SaintCyr, W. W.; Barrett, T. M.; Baumgartner, R. G.; Lott, J. W.; Fesmire, J. E.

    2009-01-01

    A full-scale field application of glass bubbles insulation has been demonstrated in a 218,000 L liquid hydrogen storage tank. This work is the evolution of extensive materials testing, laboratory scale testing, and system studies leading to the use of glass bubbles insulation as a cost efficient and high performance alternative in cryogenic storage tanks of any size. The tank utilized is part of a rocket propulsion test complex at the NASA Stennis Space Center and is a 1960's vintage spherical double wall tank with an evacuated annulus. The original perlite that was removed from the annulus was in pristine condition and showed no signs of deterioration or compaction. Test results show a significant reduction in liquid hydrogen boiloff when compared to recent baseline data prior to removal of the perlite insulation. The data also validates the previous laboratory scale testing (1000 L) and full-scale numerical modeling (3,200,000 L) of boiloff in spherical cryogenic storage tanks. The performance of the tank will continue to be monitored during operation of the tank over the coming years. KEYWORDS: Glass bubble, perlite, insulation, liquid hydrogen, storage tank.

  18. HANFORD DOUBLE SHELL TANK (DST) THERMAL & SEISMIC PROJECT SEISMIC ANALYSIS OF HANFORD DOUBLE SHELL TANKS

    Energy Technology Data Exchange (ETDEWEB)

    MACKEY, T.C.

    2006-03-17

    M&D Professional Services, Inc. (M&D) is under subcontract to Pacific Northwest National Laboratory (PNNL) to perform seismic analysis of the Hanford Site double-shell tanks (DSTs) in support of a project entitled ''Double-Shell Tank (DSV Integrity Project--DST Thermal and Seismic Analyses)''. The overall scope of the project is to complete an up-to-date comprehensive analysis of record of the DST system at Hanford in support of Tri-Party Agreement Milestone M-48-14, The work described herein was performed in support of the seismic analysis of the DSTs. The thermal and operating loads analysis of the DSTs is documented in Rinker et al. (2004). The work statement provided to M&D (PNNL 2003) required that the seismic analysis of the DSTs assess the impacts of potentially non-conservative assumptions in previous analyses and account for the additional soil mass due to the as-found soil density increase, the effects of material degradation, additional thermal profiles applied to the full structure including the soil-structure response with the footings, the non-rigid (low frequency) response of the tank roof, the asymmetric seismic-induced soil loading, the structural discontinuity between the concrete tank wall and the support footing and the sloshing of the tank waste. The seismic analysis considers the interaction of the tank with the surrounding soil and the effects of the primary tank contents. The DSTs and the surrounding soil are modeled as a system of finite elements. The depth and width of the soil incorporated into the analysis model are sufficient to obtain appropriately accurate analytical results. The analyses required to support the work statement differ from previous analysis of the DSTs in that the soil-structure interaction (SSI) model includes several (nonlinear) contact surfaces in the tank structure, and the contained waste must be modeled explicitly in order to capture the fluid-structure interaction behavior between the primary

  19. Tank characterization data report: Tank 241-C-112

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, B.C.; Borsheim, G.L.; Jensen, L.

    1993-09-01

    Tank 241-C-112 is a Hanford Site Ferrocyanide Watch List tank that was most recently sampled in March 1992. Analyses of materials obtained from tank 241-C-112 were conducted to support the resolution of the Ferrocyanide Unreviewed Safety Question (USQ) and to support Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-10-00. Analysis of core samples obtained from tank 241-C-112 strongly indicates that the fuel concentration in the tank waste will not support a propagating exothermic reaction. Analysis of the process history of the tank as well as studies of simulants provided valuable information about the physical and chemical condition of the waste. This information, in combination with the analysis of the tank waste, sup ports the conclusion that an exothermic reaction in tank 241-C-112 is not plausible. Therefore, the contents of tank 241-C-112 present no imminent threat to the workers at the Hanford Site, the public, or the environment from its forrocyanide inventory. Because an exothermic reaction is not credible, the consequences of this accident scenario, as promulgated by the General Accounting Office, are not applicable.

  20. Tank Characterization Report for Double Shell Tank (DST) 241-AN-107

    Energy Technology Data Exchange (ETDEWEB)

    ADAMS, M.R.

    2000-03-23

    This report interprets information about the tank answering a series of six questions covering areas such as information drivers, tank history, tank comparisons, disposal implications, data quality and quantity, and unique aspects of the tank.

  1. 46 CFR 154.420 - Tank design.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Tank design. 154.420 Section 154.420 Shipping COAST... SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Integral Tanks § 154.420 Tank design. (a) The structure of an integral tank must meet the deep tank scantling...

  2. 46 CFR 154.439 - Tank design.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Tank design. 154.439 Section 154.439 Shipping COAST... SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Independent Tank Type A § 154.439 Tank design. An independent tank type A must meet the deep tank standard of...

  3. 27 CFR 25.35 - Tanks.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Tanks. 25.35 Section 25.35... TREASURY LIQUORS BEER Construction and Equipment Equipment § 25.35 Tanks. Each stationary tank, vat, cask... contents of tanks or containers in lieu of providing each tank or container with a measuring device....

  4. 49 CFR 230.116 - Oil tanks.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Oil tanks. 230.116 Section 230.116 Transportation... Locomotive Tanks § 230.116 Oil tanks. The oil tanks on oil burning steam locomotives shall be maintained free... adjacent to the fuel supply tank or in another safe location; (b) Closes automatically when tripped...

  5. 14 CFR 23.1013 - Oil tanks.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil tanks. 23.1013 Section 23.1013... tanks. (a) Installation. Each oil tank must be installed to— (1) Meet the requirements of § 23.967 (a...) Expansion space. Oil tank expansion space must be provided so that— (1) Each oil tank used with...

  6. 49 CFR 238.423 - Fuel tanks.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Fuel tanks. 238.423 Section 238.423 Transportation....423 Fuel tanks. (a) External fuel tanks. Each type of external fuel tank must be approved by FRA's Associate Administrator for Safety upon a showing that the fuel tank provides a level of safety at...

  7. Accountability Tanks Calibration Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wendelberger, James G. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Salazar, William Richard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Finstad, Casey Charles [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-04-25

    MET-1 utilizes tanks to store plutonium in solution. The Nuclear Material Control & Accountability group at LANL requires that MET-1 be able to determine the amount of SNM remaining in solution in the tanks for accountability purposes. For this reason it is desired to determine how well various operators may read the volume of liquid left in the tank with the tank measurement device (glass column or slab). The accuracy of the measurement is then compared to the current SAFE-NMCA acceptance criteria for lean and rich plutonium solutions to determine whether or not the criteria are reasonable and may be met.

  8. Development of smart solar tanks

    DEFF Research Database (Denmark)

    Furbo, Simon; Andersen, Elsa

    1999-01-01

    The aim of the project is to develop smart solar tanks. A smart solar tank is a tank in which the domestic water can bee heated both by solar collectors and by an auxiliary energy supply system. The auxiliary energy supply system heats up the hot-water tank from the top and the water volume heated...... by the auxiliary energy supply system is fitted to the hot water consumption and consumption pattern. In periods with a large hot-water demand the volume is large, in periods with a small hot-water demand the volume is small. Based on measurements and calculations the advantage of smart SDHW systems is visualised....

  9. Differential Draining of Parallel-Fed Propellant Tanks in Morpheus and Apollo Flight

    Science.gov (United States)

    Hurlbert, Eric; Guardado, Hector; Hernandez, Humberto; Desai, Pooja

    2015-01-01

    Parallel-fed propellant tanks are an advantageous configuration for many spacecraft. Parallel-fed tanks allow the center of gravity (cg) to be maintained over the engine(s), as opposed to serial-fed propellant tanks which result in a cg shift as propellants are drained from tank one tank first opposite another. Parallel-fed tanks also allow for tank isolation if that is needed. Parallel tanks and feed systems have been used in several past vehicles including the Apollo Lunar Module. The design of the feedsystem connecting the parallel tank is critical to maintain balance in the propellant tanks. The design must account for and minimize the effect of manufacturing variations that could cause delta-p or mass flowrate differences, which would lead to propellant imbalance. Other sources of differential draining will be discussed. Fortunately, physics provides some self-correcting behaviors that tend to equalize any initial imbalance. The question concerning whether or not active control of propellant in each tank is required or can be avoided or not is also important to answer. In order to provide data on parallel-fed tanks and differential draining in flight for cryogenic propellants (as well as any other fluid), a vertical test bed (flying lander) for terrestrial use was employed. The Morpheus vertical test bed is a parallel-fed propellant tank system that uses passive design to keep the propellant tanks balanced. The system is operated in blow down. The Morpheus vehicle was instrumented with a capacitance level sensor in each propellant tank in order to measure the draining of propellants in over 34 tethered and 12 free flights. Morpheus did experience an approximately 20 lb/m imbalance in one pair of tanks. The cause of this imbalance will be discussed. This paper discusses the analysis, design, flight simulation vehicle dynamic modeling, and flight test of the Morpheus parallel-fed propellant. The Apollo LEM data is also examined in this summary report of the

  10. Tank closure reducing grout

    Energy Technology Data Exchange (ETDEWEB)

    Caldwell, T.B.

    1997-04-18

    A reducing grout has been developed for closing high level waste tanks at the Savannah River Site in Aiken, South Carolina. The grout has a low redox potential, which minimizes the mobility of Sr{sup 90}, the radionuclide with the highest dose potential after closure. The grout also has a high pH which reduces the solubility of the plutonium isotopes. The grout has a high compressive strength and low permeability, which enhances its ability to limit the migration of contaminants after closure. The grout was designed and tested by Construction Technology Laboratories, Inc. Placement methods were developed by the Savannah River Site personnel.

  11. 33 CFR 157.208 - Dedicated Clean Ballast Tanks Operations Manual for foreign tank vessels: Submission.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Dedicated Clean Ballast Tanks... MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Dedicated Clean Ballast Tanks on Tank Vessels General § 157.208 Dedicated Clean Ballast Tanks Operations Manual for foreign tank...

  12. Simulation Research of Vaporization and Pressure Variation in a Cryogenic Propellant Tank at the Launch Site

    Science.gov (United States)

    Chen, Liang; Liang, Guo-zhu

    2013-12-01

    In order to improve depiction of pressure variation and investigate the interrelation among the physical processes in propellant tanks, a 2D axial symmetry Volume-of-Fluid (VOF) CFD model is established to simulate a large-sized liquid propellant tank when the rocket is preparing for launch with propellant loaded at the launch site. The numerical model is considered with propellant free convection, heat transfer between the tank and the external environment, thermal exchange between propellant and inner tank wall surfaces, gas compressibility, and phase change modeled under the assumption of thermodynamic equilibrium. Vaporization rate of the vented LH2 tank and prediction of pressure change in the tank pressurized with GHe are obtained through simulation. We analysis the distributions of phase, temperature, and velocity vectors to reveal interactions among the propellant's own convection motion, heat transfer and phase change. The results show that the vaporization rate is mainly affected by heat leaks though the tank wall when the tank is vented, but it does not completely accord with the trend of the leakage because of convection motion and temperature nonuniformity of the liquid propellant in the tank. We also find that the main factors on pressure variation in the pressurized tank are the heat transfer on the tank wall surface bonding the ullage and propellant vaporization which has comparatively less influence.

  13. Tank Waste Remediation System Tank Waste Analysis Plan. FY 1995

    Energy Technology Data Exchange (ETDEWEB)

    Haller, C.S.; Dove, T.H.

    1994-11-01

    This documents lays the groundwork for preparing the implementing the TWRS tank waste analysis planning and reporting for Fiscal Year 1995. This Tank Waste Characterization Plan meets the requirements specified in the Hanford Federal Facility Agreement and Consent Order, better known as the Tri-Party Agreement.

  14. Numerical Simulation of Sloshing in Rectangular Storage Tank Using Coupled FEM-BEM

    Institute of Scientific and Technical Information of China (English)

    Hassan Saghi; Mohammad Javad Ketabdari

    2012-01-01

    Sloshing of liquid can increase the dynamic pressure on the storage sidewalls and bottom in tanker ships and LNG careers.Different geometric shapes were suggested for storage tank to minimize the sloshing pressure on tank perimeter.In this research,a numerical code was developed to model liquid sloshing in a rectangular partially filled tank.Assuming the fluid to be inviscid,Laplace equation and nonlinear free surface boundary conditions are solved using coupled FEM-BEM.The code performance for sloshing modeling is validated against available data.To minimize the sloshing pressure on tank perimeter,rectangular tanks with specific volumes and different aspect ratios were investigated and the best aspect ratios were suggested.The results showed that the rectangular tank with suggested aspect ratios,not only has a maximum surrounded tank volume to the constant available volume,but also reduces the sloshing pressure efficiently.

  15. Masses of Fluid for Cylindrical Tanks in Rock With Partial Uplift of Bottom Plate.

    Science.gov (United States)

    Taniguchi, Tomoyo; Katayama, Yukihiro

    2016-10-01

    This study proposes the use of a slice model consisting of a set of thin rectangular tanks for evaluating the masses of fluid contributing to the rocking motion of cylindrical tanks; the effective mass of fluid for rocking motion, that for rocking-bulging interaction, effective moment inertia of fluid for rocking motion and its centroid. They are mathematically or numerically quantified, normalized, tabulated, and depicted as functions of the aspect of tanks for different values of the ratio of the uplift width of the tank bottom plate to the diameter of tank for the designer's convenience.

  16. Tank waste information network system II (TWINS2) year 2000 compliance assurance plan

    Energy Technology Data Exchange (ETDEWEB)

    Adams, M.R.

    1998-04-16

    The scope of this plan includes the Tank Waste Information Network System II (TWINS2) that contains the following major components: Tank Characterization Database (TCD), Tank Vapor Database (TVD), Data Source Access (DSA), automated Tank Characterization Report, Best-Basis Inventory Model (BBIM), and Tracker (corrective action tracking) function. The automated Tank Characterization Report application currently in development also will reside on-the TWINS system as will the BBIM. Critical inputs to TWINS occur from the following databases: Labcore and SACS. Output does not occur from TWINS to these two databases.

  17. Reducing roll motion by passive free surface tanks

    DEFF Research Database (Denmark)

    Nielsen, Ulrik Dam; Nielsen, Christian S.

    2014-01-01

    Roll stabilisation of motorised vessels plays an important part in reducing passenger discomfort and increasing safety and cargo capacity. Passive free surface tanks are considered a low-cost stabilising method, which is efficient at all speeds without increasing hull resistance. In this study......, a mathematical model for evaluating the performance of a passive free surface tank is established. This is done by coupling a roll model to a fluid flow model. As a numerical example, the seakeeping abilities of a container vessel are evaluated. The necessary methods for performing the simulation are presented...... and the design of a free surface tank is explained. The effects of the passive free surface tank are evaluated and a significant damping effect is observed, particularly in cases with resonant roll....

  18. Static Stress Analysis of Security Injection Tank

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The static structural analysis of the security injection tank is made to make sure whether the tank can withstand concerned loads or not on all conditions conforming to concerned code prescripts and design requirements. The tanks

  19. Oil Storage Facilities - Storage Tank Locations

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — A Storage Tank Location is a DEP primary facility type, and its sole sub-facility is the storage tank itself. Storage tanks are aboveground or underground, and are...

  20. Criticality safety assessment of tank 241-C-106 remediation

    Energy Technology Data Exchange (ETDEWEB)

    Waltar, A.E., Westinghouse Hanford

    1996-07-19

    A criticality safety assessment was performed in support of Project 320 for the retrieval of waste from tank 241-C-106 to tank 241-AY-102. The assessment was performed by a multi-disciplined team consisting of expertise covering the range of nuclear engineering, plutonium and nuclear waste chemistry,and physical mixing hydraulics. Technical analysis was performed to evaluate the physical and chemical behavior of fissile material in neutralized Hanford waste as well as modeling of the fluid dynamics for the retrieval activity. The team has not found evidence of any credible mechanism to attain neutronic criticality in either tank and has concluded that a criticality accident is incredible.

  1. Attenuating water hammer pressure by means of gas storage tank

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The basic equations for computing the volume of gas storage tank were derived from the principles of attenuating water hammer pressure. Verifications using experiments indicate that the proposed equation can provide a fare precision in the predictions. By using the model of solid-liquid two-phase flow, the gas storage tank, pressure-relief valves and slow-closure reverse-control valves were compared with practical engineering problems, and the functions of gas storage tank in attenuating water hammer pressure were further investigated.

  2. Tank characterization report for single-shell tank 241-C-110. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Benar, C.J.

    1997-06-14

    One of the major functions of the Tank Waste Remediation System (IWRS) is to characterize wastes in support of waste management and disposal activities at the Hanford Site. Analytical data from sampling and analysis, along with other available information about a tank, are compiled and maintained in a tank characterization report (TCR). This report and its appendixes serve as the TCR for single-shell tank 241-C-110. The objectives of this report are to use characterization data in response to technical issues associated with 241-C-110 waste and to provide a standard characterization of this waste in terms of a best-basis inventory estimate. Supporting data and information are contained in the appendixes. This report also supports the requirements of the Hanford Federal Facility Agreement and Consent Order milestone M-44-05. Characterization information presented in this report originated from sample analyses and known historical sources. While only the results from recent sample events will be used to fulfill the requirements of the data quality objectives (DQOs), other information can be used to support or question conclusions derived from these results. Historical information for tank 241-C-110 are provided included surveillance information, records pertaining to waste transfers and tank operations, and1124 expected tank contents derived from a process knowledge model. The sampling events are listed, as well as sample data obtained before 1989. The results of the 1992 sampling events are also reported in the data package. The statistical analysis and numerical manipulation of data used in issue resolution are reported in Appendix C. Appendix D contains the evaluation to establish the best basis for the inventory estimate and the statistical analysis performed for this evaluation. A bibliography that resulted from an in-depth literature search of all known information sources applicable to tank 241-C-110 and its respective waste types is contained in Appendix E

  3. Assessing the applicability of the 1D flux theory to full-scale secondary settling tank design with a 2D hydrodynamic model.

    Science.gov (United States)

    Ekama, G A; Marais, P

    2004-02-01

    The applicability of the one-dimensional idealized flux theory (1DFT) for the design of secondary settling tanks (SSTs) is evaluated by comparing its predicted maximum surface overflow (SOR) and solids loading (SLR) rates with that calculated with the two-dimensional computational fluid dynamics model SettlerCAD using as a basis 35 full-scale SST stress tests conducted on different SSTs with diameters from 30 to 45m and 2.25-4.1m side water depth (SWD), with and without Stamford baffles. From the simulations, a relatively consistent pattern appeared, i.e. that the 1DFT can be used for design but its predicted maximum SLR needs to be reduced by an appropriate flux rating, the magnitude of which depends mainly on SST depth and hydraulic loading rate (HLR). Simulations of the Watts et al. (Water Res. 30(9)(1996)2112) SST, with doubled SWDs and the Darvill new (4.1m) and old (2.5m) SSTs with interchanged depths, were run to confirm the sensitivity of the flux rating to depth and HLR. Simulations with and without a Stamford baffle were also performed. While the design of the internal features of the SST, such as baffling, has a marked influence on the effluent SS concentration while the SST is underloaded, these features appeared to have only a small influence on the flux rating, i.e. capacity, of the SST. Until more information is obtained, it would appear from the simulations that the flux rating of 0.80 of the 1DFT maximum SLR recommended by Ekama and Marais (Water Pollut. Control 85(1)(1986)101) remains a reasonable value to apply in the design of full-scale SSTs-for deep SSTs (4m SWD) the flux rating could be increased to 0.85 and for shallow SSTs (2.5m SWD) decreased to 0.75. It is recommended that (i) while the apparent interrelationship between SST flux rating and depth suggests some optimization of the volume of the SST, this be avoided and (ii) the depth of the SST be designed independently of the surface area as is usually the practice and once selected, the

  4. Cleaning Validation of Fermentation Tanks

    DEFF Research Database (Denmark)

    Salo, Satu; Friis, Alan; Wirtanen, Gun

    2008-01-01

    Reliable test methods for checking cleanliness are needed to evaluate and validate the cleaning process of fermentation tanks. Pilot scale tanks were used to test the applicability of various methods for this purpose. The methods found to be suitable for validation of the clenlinees were visula...

  5. Solitons in a wave tank

    Science.gov (United States)

    Olsen, M.; Smith, H.; Scott, A. C.

    1984-09-01

    A wave tank experiment (first described by the nineteenth-century engineer and naval architect John Scott Russell) relates a linear eigenvalue problem from elementary quantum mechanics to a striking feature of modern nonlinear wave theory: multiple generation of solitons. The tank experiment is intended for lecture demonstrations.

  6. Cleaning Validation of Fermentation Tanks

    DEFF Research Database (Denmark)

    Salo, Satu; Friis, Alan; Wirtanen, Gun

    2008-01-01

    Reliable test methods for checking cleanliness are needed to evaluate and validate the cleaning process of fermentation tanks. Pilot scale tanks were used to test the applicability of various methods for this purpose. The methods found to be suitable for validation of the clenlinees were visula o...

  7. Solitons in a wave tank

    DEFF Research Database (Denmark)

    Olsen, M.; Smith, H.; Scott, Alwyn C.

    1984-01-01

    A wave tank experiment (first described by the nineteenth-century engineer and naval architect John Scott Russell) relates a linear eigenvalue problem from elementary quantum mechanics to a striking feature of modern nonlinear wave theory: multiple generation of solitons. The tank experiment...

  8. Ditching Tests with a 1/12-Scale Model of the Army A-26 Airplane in Langley Tank No. 2 and on an Outdoor Catapult

    Science.gov (United States)

    Jarvis, George A.; Hoffman, Edward L.

    1947-01-01

    Tests were conducted in calm water in Langley tank no. 2 and in calm and rough water at an outdoor catapult in order to determine the best way to make a forced landing of an Army A-26 airplane and to determine its probable ditching behavior. These tests were requested by the Air Materiel Command, Army Air Forces, in their letter of March 26, 1943, WEL:AW:50.

  9. Competitive Think Tanks in Europe

    DEFF Research Database (Denmark)

    Kelstrup, Jesper Dahl

    in opportunity structures that are mediated by historically constituted institutions in knowledge regimes. The paper distinguishes between four different strategies, the authoritative, the collaborative, the agenda-setting and the competitive strategy that are distinguished by the relations think tanks have...... to established institutions and power in public policy. On the basis of the hypothesis that more competitive think tanks have emerged due to lower opportunity costs, the paper investigates how ‘competitive’ think tank strategies have been used in Germany, Denmark, the EU-institutions in Brussels...... and in the United Kingdom from 2000 to 2012. The findings contradict the hypothesis that the competitive think tank strategy is the dominant or even a common strategy across the cases under investigation. The competitive strategy is particularly rare among EU and German think tanks. As such the paper challenges...

  10. Surplus yeast tank failing catastrophically

    DEFF Research Database (Denmark)

    Hedlund, Frank Huess

    2016-01-01

    GOOD REASON FOR CAUTION I A large surplus yeast tank shot into the air leaving the floor plate and the contents behind. Although not designed for overpressure, the tank was kept at “very slight overpressure” to suppress nuisance foaming. The brewery was unaware of the hazards of compressed air. T....... The accident described in this article serves to illustrate that care should be taken if a tank originally designed for atmospheric pressure is modified to operate at slight overpressure.......GOOD REASON FOR CAUTION I A large surplus yeast tank shot into the air leaving the floor plate and the contents behind. Although not designed for overpressure, the tank was kept at “very slight overpressure” to suppress nuisance foaming. The brewery was unaware of the hazards of compressed air...

  11. In-tank photo analysis

    Energy Technology Data Exchange (ETDEWEB)

    Vorvick, C.A.; Baird, D.B.; Heasler, P.G. [and others

    1995-09-01

    This report documents an analysis performed by Pacific Northwest Laboratory (PNL) of photographs showing the interior of a single shell tank (SST) at the Hanford site. This report shows that in-tank photos can be used to create a plan-view map of the waste surface inside a tank, and that measuring the elevation of the waste surface from the photos is possible, but not accurate enough to be useful at this time. In-tank photos were acquired for Tanks BX111 and T111. The BX111 photos were used to create the waste surface map and to measure the waste surface elevation. T111 photos were used to measure the waste surface elevation. Uncertainty analyses of the mapping and surface elevation are included to show the accuracy of the calculations for both methods.

  12. Study on safety monitoring model of petroleum tank farm based on multi-source data fusion%基于多源数据融合的石油罐区安全监控模型∗

    Institute of Scientific and Technical Information of China (English)

    易高翔; 潘长城; 郭建中; 王时彬; 王如君; 康荣学

    2014-01-01

    Due to the single sensor in the safety monitoring of oil tank farm is easily influenced by external factors and resultes in errors, in order to improve the reliability of sensor detection and the accuracy of tank farm safety mo-nitoring, based on the multi-source data fusion technology, an early-worning model of safety status in tank farm was established. Firstly the 3 levels of multi-source data fusion technology were introduced including data level fu-sion, feature level fusion and decision level fusion, as well as the common data fusion methods. Secondly the 1st level fusion model based on optimal weighted fusion algorithm and 2 nd level fusion model based on BP neural net-work algorithm were established. Ffinally safety monitoring data fusion model of oil tank farm was obtained, which provides the theory basis for further practice application.%由于单一传感器在石油罐区安全监控中容易受到外界因素影响从而产生误差,为提高传感器检测结果的可靠性和罐区安全监控预警的准确性,基于多源数据融合技术,建立罐区安全状态预警模型。首先,介绍了多源数据融合技术的3个层级:数据级融合,特征级融合和决策级融合,以及目前各领域常见的数据融合方法;其次,建立了基于最优加权融合算法的一级融合模型和基于BP神经网络算法的二级融合模型;最后,得到石油罐区安全监控数据融合模型,并为进一步的实践应用打下了理论基础。

  13. Small-Scale Metal Tanks for High Pressure Storage of Fluids

    Science.gov (United States)

    London, Adam (Inventor)

    2016-01-01

    Small scale metal tanks for high-pressure storage of fluids having tank factors of more than 5000 meters and volumes of ten cubic inches or less featuring arrays of interconnected internal chambers having at least inner walls thinner than gage limitations allow. The chambers may be arranged as multiple internal independent vessels. Walls of chambers that are also portions of external tank walls may be arcuate on the internal and/or external surfaces, including domed. The tanks may be shaped adaptively and/or conformally to an application, including, for example, having one or more flat outer walls and/or having an annular shape. The tanks may have dual-purpose inlet/outlet conduits of may have separate inlet and outlet conduits. The tanks are made by fusion bonding etched metal foil layers patterned from slices of a CAD model of the tank. The fusion bonded foil stack may be further machined.

  14. CFD simulations of filling and emptying of hydrogen tanks

    OpenAIRE

    MELIDEO DANIELE; BARALDI DANIELE; ACOSTA IBORRA BEATRIZ; ORTIZ CEBOLLA RAFAEL; MORETTO PIETRO

    2016-01-01

    During the filling of hydrogen tanks high temperatures can be generated inside the vessel because of the gas compression while during the emptying low temperatures can be reached because of the gas expansion. The design temperature range goes from 40 C to 85 C. Temperatures outside that range could affect the mechanical properties of the tank materials. CFD analyses of the filling and emptying processes have been performed in the HyTransfer project. To assess the accuracy of the CFD model the...

  15. Tank-automotive robotics

    Science.gov (United States)

    Lane, Gerald R.

    1999-07-01

    To provide an overview of Tank-Automotive Robotics. The briefing will contain program overviews & inter-relationships and technology challenges of TARDEC managed unmanned and robotic ground vehicle programs. Specific emphasis will focus on technology developments/approaches to achieve semi- autonomous operation and inherent chassis mobility features. Programs to be discussed include: DemoIII Experimental Unmanned Vehicle (XUV), Tactical Mobile Robotics (TMR), Intelligent Mobility, Commanders Driver Testbed, Collision Avoidance, International Ground Robotics Competition (ICGRC). Specifically, the paper will discuss unique exterior/outdoor challenges facing the IGRC competing teams and the synergy created between the IGRC and ongoing DoD semi-autonomous Unmanned Ground Vehicle and DoT Intelligent Transportation System programs. Sensor and chassis approaches to meet the IGRC challenges and obstacles will be shown and discussed. Shortfalls in performance to meet the IGRC challenges will be identified.

  16. Chemical information on tank supernatants, Cs adsorption from tank liquids onto Hanford sediments, and field observations of Cs migration from past tank leaks

    Energy Technology Data Exchange (ETDEWEB)

    Serne, R.J.; Zachara, J.M.; Burke, D.S.

    1998-01-01

    Borehole gamma-logging profiles beneath the SX-Tank Farm suggest that contamination from Cs-137 extends to at least a depth of 40 m (130 ft), and may extend even deeper. What is presently not known is the pathway that Cs-137 has taken to reach these depths. In this report we provide an analysis of the chemistry of tank supernates with emphasis on the REDOX waste stream disposed in SX tanks, Cs chemistry in aqueous solutions and adsorption properties onto minerals, available data on Cs adsorption onto Hanford sediments, and information on Cs migration from other Hanford tank leaks that have been studied. The data in this report was used to help guide the vadose zone transport analysis of the SX Tank Farm presented in a companion report. The goal of the vadose zone transport modelling is to attempt to explain the depth and extent of the Cs-137 plume under the SX Tank farm, specifically in the vicinity of the greatest leak, near the SX-109 Tank as inferred from the gamma logs (DOE 1996). In solution Cs is present as the monovalent cation and shows very little tendency to form aqueous complexes with inorganic or organic ligands. Cs is expected to adsorb primarily onto selective minerals that have unique adsorption sites. The small Cs{sup +} ion is accommodated on these frayed edge and interlayer sites. Adsorption within the interlayers often leads to collapse of the layers such that the Cs{sup +} ion is effectively trapped and not readily exchangeable by all other common cations. The degree of adsorption is thus only moderately dependent on the types and high concentrations of other cations in leaking tank liquors.

  17. Parametric Weight Study of Cryogenic Metallic Tanks for the ``Bimodal'' NTR Mars Vehicle Concept

    Science.gov (United States)

    Kosareo, Daniel N.; Roche, Joseph M.

    2006-01-01

    A parametric weight assessment of large cryogenic metallic tanks was conducted using the design optimization capabilities in the ANSYS ® finite element analysis code. This analysis was performed to support the sizing of a ``bimodal'' nuclear thermal rocket (NTR) Mars vehicle concept developed at the NASA Glenn Research Center. The tank design study was driven by two load conditions: an in-line, ``Shuttle-derived'' heavy-lift launch with the tanks filled and pressurized, and a burst-test pressure. The main tank structural arrangement is a state-of-the art metallic construction which uses an aluminum-lithium alloy stiffened internally with a ring and stringer framework. The tanks must carry liquid hydrogen in separate launches to orbit where all vehicle components will dock and mate. All tank designs stayed within the available mass and payload volume limits of both the in-line heavy lift and Shuttle derived launch vehicles. Weight trends were developed over a range of tank lengths with varying stiffener cross-sections and tank wall thicknesses. The object of this parametric study was to verify that the proper mass was allocated for the tanks in the overall vehicle sizing model. This paper summarizes the tank weights over a range of tank lengths.

  18. 49 CFR 180.519 - Periodic retest and inspection of tank cars other than single-unit tank car tanks.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Periodic retest and inspection of tank cars other... of Tank Cars § 180.519 Periodic retest and inspection of tank cars other than single-unit tank car... devices must be retested periodically as specified in Retest Table 1 of paragraph (b)(5) of this...

  19. Tank characterization report for double shell tank 241-AP-104

    Energy Technology Data Exchange (ETDEWEB)

    Winkelman, W.D., Westinghouse Hanford

    1996-08-07

    This document summarizes the information on the historical uses, present status, and the sampling and analysis results of waste stored in Tank 241-AP-104. This report supports the requirements of Tri-Party Agreement Milestone M-44-09.

  20. Tank vapor mitigation requirements for Hanford Tank Farms

    Energy Technology Data Exchange (ETDEWEB)

    Rakestraw, L.D.

    1994-11-15

    Westinghouse Hanford Company has contracted Los Alamos Technical Associates to listing of vapors and aerosols that are or may be emitted from the High Level Waste (HLW) tanks at Hanford. Mitigation requirements under Federal and State law, as well as DOE Orders, are included in the listing. The lists will be used to support permitting activities relative to tank farm ventilation system up-grades. This task is designated Task 108 under MJB-SWV-312057 and is an extension of efforts begun under Task 53 of Purchase Order MPB-SVV-03291 5 for Mechanical Engineering Support. The results of that task, which covered only thirty-nine tanks, are repeated here to provide a single source document for vapor mitigation requirements for all 177 HLW tanks.

  1. Tank characterization report for single shell tank 241-S-107

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, B.C.

    1996-09-19

    This document summarizes the information on the historical uses, present status, and the sampling and analysis results of waste stored in Tank 241-S-107. This report supports the requirements of Tri- Party Agreement Milestone M-44-09.

  2. Tank characterization report for single shell tank 241-S-107

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, B.C.

    1996-09-19

    This document summarizes the information on the historical uses, present status, and the sampling and analysis results of waste stored in Tank 241-S-107. This report supports the requirements of Tri- Party Agreement Milestone M-44-09.

  3. Tank characterization report for single-shell Tank B-201

    Energy Technology Data Exchange (ETDEWEB)

    Heasler, P.G.; Remund, K.M.; Tingey, J.M.; Baird, D.B.; Ryan, F.M.

    1994-09-01

    The purpose of this report is to characterize the waste in single shell Tank B-201. Characterization includes the determination of the physical, chemical (e.g., concentrations of elements and organic species), and radiological properties of the waste. These determinations are made using analytical results from B-201 core samples as well as historical information about the tank. The main objective is to determine average waste properties: but in some cases, concentrations of analytes as a function of depth were also determined. This report also consolidates the available historical information regarding Tank B-201, arranges the analytical information from the recent core sampling in a useful format, and provides an interpretation of the data within the context of what is known about the tank.

  4. Ecodesign of Liquid Fuel Tanks

    Science.gov (United States)

    Gicevska, Jana; Bazbauers, Gatis; Repele, Mara

    2011-01-01

    The subject of the study is a 10 litre liquid fuel tank made of metal and used for fuel storage and transportation. The study dealt with separate life cycle stages of this product, compared environmental impacts of similar fuel tanks made of metal and plastic, as well as analysed the product's end-of-life cycle stage, studying the waste treatment and disposal scenarios. The aim of this study was to find opportunities for improvement and to develop proposals for the ecodesign of 10 litre liquid fuel tank.

  5. [Death in a relaxation tank].

    Science.gov (United States)

    Rupp, Wolf; Simon, Karl-Heinz; Bohnert, Michael

    2009-01-01

    Complete relaxation can be achieved by floating in a darkened, sound-proof relaxation tank filled with salinated water kept at body temperature. Under these conditions, meditation exercises up to self-hypnosis may lead to deep relaxation with physical and mental revitalization. A user manipulated his tank, presumably to completely cut off all optical and acoustic stimuli and accidentally also covered the ventilation hole. The man was found dead in his relaxation tank. The findings suggested lack of oxygen as the cause of death.

  6. 液体火箭贮箱增压排液过程三种气枕模型的数值对比%Numerical comparison of three ullage models for the tank pressurization process of liquid rocket during outflow

    Institute of Scientific and Technical Information of China (English)

    王磊; 厉彦忠; 李翠; 赵志翔

    2011-01-01

    针对液氧贮箱氦气增压排液过程,分别建立了零维整体模型、一维分层模型及二维计算流体力学(CFD)模型对气枕物理场的变化规律进行数值研究.零维及一维模型采用经验公式求解气枕与壁面间的换热量,而二维CFD模型通过低雷诺数k-ε模型确定流体与固壁间的耦合换热作用.计算时氦气采用理想气体模型.利用三种模型分别预测了贮箱内气枕压力、气枕平均温度及温度分布规律.计算结果表明:三组结果分布合理,不同模型的结果之间能够互相印证;对于气枕及与气枕接触壁面沿轴向的温度分布,在气枕主体区一维模型与二维模型预测结果基本吻合,而在靠近消能器的气枕上端,两种模型预测值存在偏差;当增压气体入口速度较大时,气枕上端径向温度分层明显,需采用二维CFD模型才能展示气枕物理场分布.%In view of the process of helium pressurization in a liquid oxygen tank during outflow,the numerical methods of zero-dimensional integrated model,one-dimensional stratification model and two-dimensional computational fluid dynamics(CFD) model were adopted to study the variation law of ullage physical field,respectively.An empirical formula was set up to solve the heat transfer rate between ullage and tank wall in the zero-dimensional model and in the one-dimension model,while the low Reynolds number k-ε model was selected to calculate the coupled heat transfer rate between fluid and tank wall in the two-dimensional CFD model.The helium density was calculated by the ideal-gas model.The ullage pressure,ullage average temperature and temperature distribution were forecasted by these three models,respectively.The computational results show that the forecasted ullage pressure and ullage average temperature of three models show reasonable distribution,and the results of different models can be confirmed one another.In addition,the calculated axial temperature

  7. Failure Diagnosis for the Holdup Tank System via ISFA

    Energy Technology Data Exchange (ETDEWEB)

    Li, Huijuan; Bragg-Sitton, Shannon; Smidts, Carol

    2016-11-01

    This paper discusses the use of the integrated system failure analysis (ISFA) technique for fault diagnosis for the holdup tank system. ISFA is a simulation-based, qualitative and integrated approach used to study fault propagation in systems containing both hardware and software subsystems. The holdup tank system consists of a tank containing a fluid whose level is controlled by an inlet valve and an outlet valve. We introduce the component and functional models of the system, quantify the main parameters and simulate possible failure-propagation paths based on the fault propagation approach, ISFA. The results show that most component failures in the holdup tank system can be identified clearly and that ISFA is viable as a technique for fault diagnosis. Since ISFA is a qualitative technique that can be used in the very early stages of system design, this case study provides indications that it can be used early to study design aspects that relate to robustness and fault tolerance.

  8. Modeling potential occupational inhalation exposures and associated risks of toxic organics from chemical storage tanks used in hydraulic fracturing using AERMOD.

    Science.gov (United States)

    Chen, Huan; Carter, Kimberly E

    2017-05-01

    Various toxic chemicals used in hydraulic fracturing fluids may influence the inherent health risks associated with these operations. This study investigated the possible occupational inhalation exposures and potential risks related to the volatile organic compounds (VOCs) from chemical storage tanks and flowback pits used in hydraulic fracturing. Potential risks were evaluated based on radial distances between 5 m and 180 m from the wells for 23 contaminants with known inhalation reference concentration (RfC) or inhalation unit risks (IUR). Results show that chemicals used in 12.4% of the wells posed a potential acute non-cancer risks for exposure and 0.11% of the wells with may provide chronic non-cancer risks for exposure. Chemicals used in 7.5% of the wells were associated with potential acute cancer risks for exposure. Those chemicals used in 5.8% of the wells may be linked to chronic cancer risks for exposure. While eight organic compounds were associated with acute non-cancer risks for exposure (>1), methanol the major compound in the chemical storage tanks (1.00-45.49) in 7,282 hydraulic fracturing wells. Wells with chemicals additives containing formaldehyde exhibited both acute and chronic cancer risks for exposure with IUR greater than 10(-6), suggesting formaldehyde was the dominant contributor to both types of risks for exposure in hydraulic fracturing. This study also found that due to other existing on-site emission sources of VOCs and the geographically compounded air concentrations from other surrounding wells, chemical emissions data from storage tanks and flowback pits used in this study were lower than reported concentrations from field measurements where higher occupational inhalation risks for exposure may be expected.

  9. HANFORD DOUBLE SHELL TANK THERMAL AND SEISMIC PROJECT SEISMIC ANALYSIS IN SUPPORT OF INCREASED LIQUID LEVEL IN 241-AP TANK FARMS

    Energy Technology Data Exchange (ETDEWEB)

    TC MACKEY; FG ABATT; MW RINKER

    2009-01-14

    The essential difference between Revision 1 and the original issue of this report is in the spring constants used to model the anchor bolt response for the anchor bolts that tie the steel dome of the primary tank to the concrete tank dome. Consequently, focus was placed on the changes in the anchor bolt responses, and a full reevaluation of all tank components was judged to be unnecessary. To confirm this judgement, primary tank stresses from the revised analysis of the BES-BEC case are compared to the original analysis and it was verified that the changes are small, as expected.

  10. DECOUPLER DESIGN FOR AN INTERACTING TANKS SYSTEM

    Directory of Open Access Journals (Sweden)

    Duraid F. Ahmed

    2013-05-01

    Full Text Available The mathematical model forthe two interacting tanks system was derived and the dynamic behavior of thissystem was studied by introducing a step change in inlet flow rate. In thispaper, the analysis of the interaction loops between the controlled variable(liquid level and manipulated variable (inlet flow rate was carried out usingthe relative gain array. Also decoupling technique is applied to eliminate theeffect this interaction by design suitable decouplers for the system. Theresults show that the gain of each loop is cut in half when the opposite loopis closed and the gain of other loop changes sign when the opposite loop isclosed. The decoupling method show that the liquid level of tank one isconstant when the second inlet flow changes and to keep the liquid level oftank two constant the first inlet flow must be changed.

  11. 46 CFR 154.446 - Tank design.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Tank design. 154.446 Section 154.446 Shipping COAST... SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Independent Tank Type B § 154.446 Tank design. An independent tank type B must meet the calculations under §...

  12. 40 CFR 265.1085 - Standards: Tanks.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Tanks. 265.1085 Section 265... FACILITIES Air Emission Standards for Tanks, Surface Impoundments, and Containers § 265.1085 Standards: Tanks. (a) The provisions of this section apply to the control of air pollutant emissions from tanks...

  13. 40 CFR 63.685 - Standards: Tanks.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Standards: Tanks. 63.685 Section 63... Standards: Tanks. (a) The provisions of this section apply to the control of air emissions from tanks for.... (b) The owner or operator shall control air emissions from each tank subject to this section...

  14. 27 CFR 24.167 - Tanks.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Tanks. 24.167 Section 24... TREASURY LIQUORS WINE Construction and Equipment § 24.167 Tanks. (a) General. All tanks on wine premises... the intended purpose. Each tank used for wine operations will be located, constructed, and equipped...

  15. 7 CFR 58.218 - Surge tanks.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Surge tanks. 58.218 Section 58.218 Agriculture....218 Surge tanks. If surge tanks are used for hot milk, and temperatures of product including foam being held in the surge tank during processing, is not maintained at a minimum of 150 °F, then two...

  16. 14 CFR 25.1013 - Oil tanks.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil tanks. 25.1013 Section 25.1013... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Oil System § 25.1013 Oil tanks. (a) Installation. Each oil tank installation must meet the requirements of § 25.967. (b) Expansion space. Oil tank...

  17. 14 CFR 27.1013 - Oil tanks.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil tanks. 27.1013 Section 27.1013... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Oil System § 27.1013 Oil tanks. Each oil tank must be... space of not less than the greater of 10 percent of the tank capacity or 0.5 gallon, and where used...

  18. 14 CFR 29.1013 - Oil tanks.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil tanks. 29.1013 Section 29.1013... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Oil System § 29.1013 Oil tanks. (a) Installation. Each oil tank installation must meet the requirements of § 29.967. (b) Expansion space. Oil tank...

  19. 40 CFR 264.1084 - Standards: Tanks.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Tanks. 264.1084 Section 264... Emission Standards for Tanks, Surface Impoundments, and Containers § 264.1084 Standards: Tanks. (a) The provisions of this section apply to the control of air pollutant emissions from tanks for which §...

  20. 7 CFR 58.320 - Brine tanks.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Brine tanks. 58.320 Section 58.320 Agriculture....320 Brine tanks. Brine tanks used for the treating of parchment liners shall be constructed of... liners. The tank should also be provided with a satisfactory drainage outlet....

  1. The Politics of Think Tanks in Europe

    DEFF Research Database (Denmark)

    Kelstrup, Jesper Dahl

    of a typology of think tanks, quantitative data and interviews with think tank practitioners, the interplay between state and market dynamics and the development of different types of think tanks is analysed. Although think tanks develop along different institutional trajectories, it is concluded that the Anglo...

  2. Underground Storage Tanks in Iowa

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Underground storage tank (UST) sites which store petroleum in Iowa. Includes sites which have been reported to DNR, and have active or removed underground storage...

  3. Integral Radiator and Storage Tank

    Science.gov (United States)

    Burke, Kenneth A.; Miller, John R.; Jakupca, Ian; Sargi,Scott

    2007-01-01

    A simplified, lightweight system for dissipating heat of a regenerative fuel- cell system would include a heat pipe with its evaporator end placed at the heat source and its condenser end integrated into the wall of the regenerative fuel cell system gas-storage tanks. The tank walls act as heat-radiating surfaces for cooling the regenerative fuel cell system. The system was conceived for use in outer space, where radiation is the only physical mechanism available for transferring heat to the environment. The system could also be adapted for use on propellant tanks or other large-surface-area structures to convert them to space heat-radiating structures. Typically for a regenerative fuel cell system, the radiator is separate from the gas-storage tanks. By using each tank s surface as a heat-radiating surface, the need for a separate, potentially massive radiator structure is eliminated. In addition to the mass savings, overall volume is reduced because a more compact packaging scheme is possible. The underlying tank wall structure provides ample support for heat pipes that help to distribute the heat over the entire tank surface. The heat pipes are attached to the outer surface of each gas-storage tank by use of a high-thermal conductance, carbon-fiber composite-material wrap. Through proper choice of the composite layup, it is possible to exploit the high longitudinal conductivity of the carbon fibers (greater than the thermal conductivity of copper) to minimize the unevenness of the temperature distribution over the tank surface, thereby helping to maximize the overall heat-transfer efficiency. In a prototype of the system, the heat pipe and the composite wrap contribute an average mass of 340 g/sq m of radiator area. Lightweight space radiator panels have a mass of about 3,000 g/sq m of radiator area, so this technique saves almost 90 percent of the mass of separate radiator panels. In tests, the modified surface of the tank was found to have an emissivity of 0

  4. Fuzzy System for Prognosis of Tank Failure Based on Neural Network

    Institute of Scientific and Technical Information of China (English)

    Li Guan

    2005-01-01

    A system for prognosis of tank failures was set up based on the results of analysis on fault phenomena. An algorithm incorporating fuzzy mathematics with the BP neural network was used to solve this prognosis model, and the availability of this model was also analyzed. This neural network-based fuzzy system for prognosis of tank failures has been put into operation at Huangdao oil terminal. The application results have shown that this system is effective for real-time prognosis of various potential tank failures and timely adoption of mitigative measures to avoid major tank accidents, which would have great significance for safeguarding the safe operation of the oil terminal.

  5. CORRELATION OF EXPERIMENTAL AND THEORETICAL HEAT TRANSFER IN MANTLE TANKS USED IN LOW FLOW SDHW SYSTEMS

    DEFF Research Database (Denmark)

    Shah, Louise Jivan; Furbo, Simon

    1998-01-01

    Experimental and theoretical investigations of vertical mantle tanks for solar domestic hot water systems have been carried out. Differently designed mantle tanks have been evaluated in a laboratory test facility and a transient three-dimensional CFD-model of one of the mantle tanks is developed...... in the CFD-program CFX 4.1. The model is validated against the experimental tests and good agreement between measured and calculated results are achieved. The results from the CFD-calculations are used to illustrate the thermal behaviour and the fluid dynamics in the mantle and in the inner tank. The CFD......-calculations are used to carry out a detailed analysis of the heat transfer from the solar collector fluid to the wall of the inner tank. The analysis has resulted in a local Nusselt-Rayleigh correlation for the heat transfer between the solar collector fluid and the wall of the inner tank....

  6. Reactor models for a series of continuous stirred tank reactors with a gas-liquid-solid leaching system: Part III. Model application

    Science.gov (United States)

    Papangelakis, V. G.; Demopoulos, G. P.

    1992-12-01

    A mathematical model developed to describe the steady-state performance of a three-phase leaching reactor is applied to the analysis and simulation of an industrial process: the high-temperature (180 °C to 200 °C) aqueous pressure oxidation (O2-H2SO4) of refractory pyrite-arsenopyrite (FeS2-FeAsS) gold concentrates. The simulation work reported here centers on the analysis of the autothermal operation of a continuous multistage horizontal autoclave. The focus is on the performance of the first autoclave compartment, since its autothermal “initialization” determines the rate of the whole process. The analysis of the whole autoclave is subsequently done on a stage-by-stage basis. The model considers both possible reaction control regimes, that is, reactor operation limited by the rate of the particle dissolution reaction (surface reaction control) or limited by the rate of O2 transfer at the g-1 interface (gas-transfer control). The decision whether the reactor operates under surface reaction control or gas transfer control is based on whether the gas-transfer capacity of the reactor can or cannot satisfy the oxygen demands of the leaching reactions. With the aid of the model, the effects of feed rate, feed preheating, cooling with water injection, slurry recycling, and autoclave configuration are critically evaluated from the standpoint of optimum autoclave performance.

  7. Research on the Sustainable Development Model of Think Tank Based on the Multidiscipline Support%基于多学科支撑的智库可持续发展模式研究

    Institute of Scientific and Technical Information of China (English)

    李春美; 魏凤

    2016-01-01

    Purpose/Significance] The construction of high level think tank is the hot spot at home and abroad. Exploring the construc-tion and the sustainable development model of high level think tank, can provide new development ideas for the construction of high level think tank in China. [ Method/Process] This paper adopts the empirical analysis to make a comparative analysis on the three international first-class think tank such as WRI, NIESR and CASS in aspects of the working process, research methods development tools, product forms, and organization modes. [ Result/Conclusion] It is considered that the characteristics of the working methods are as follows:reali-zing the dynamic collecting and updating of data resources with the data mining, satellite remote sensing and the advanced technology of other disciplines; combining the research methods of economics, statistics, management science, sociology and other disciplines to achieve the sustainable improving of model method and the development of the new tool platform;forming the core products by learning the prod-uct forms of different fields such as database, analysis tools and platforms, reports and monographs;and adopting the open and cooperative way to gather the transnational experts of relevant fields to carry out related work. On the basis of this, the sustainable development model of think tank based on the multidiscipline support is put forward.%[目的/意义]建设高水平智库是目前国内外关注的热点。探索高水平智库的建设和可持续发展模式,能够为我国高水平智库建设提供新的发展思路。[方法/过程]采用实证分析的方法,选取WRI、NIESR、CASS三个国际一流智库,对其工作流程、研究方法及开发工具、产品形式、组织方式等方面进行比较分析。[结果/结论]认为其在工作方法上的特点主要体现在:结合数据挖掘、卫星遥感等多学科的先进技术实现数据资源的动态采集和更新;将

  8. Tank 241-C-109 vapor sampling and analysis tank characterization report. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Huckaby, J.L.

    1995-05-31

    This report presents the details of the Hanford waste tank characterization study for tank C-109. The drivers and objectives of the waste tank headspace vapor sampling and analysis were in accordance with procedures that were presented in other reports.

  9. Hazard assessments of double-shell flammable gas tanks

    Energy Technology Data Exchange (ETDEWEB)

    Fox, G.L.; Stepnewski, D.D.

    1994-09-28

    This report is the fourth in a series of hazard assessments performed on the double-shell flammable gas watch list tanks. This report focuses on hazards associated with the double-shell watch list tanks (101-AW, 103-AN, 104-AN, and 105-AN). While a similar assessment has already been performed for tank 103-SY, it is also included here to incorporate a more representative slurry gas mixture and provide a consistent basis for comparing results for all the flammable gas tanks. This report is intended to provide an in-depth assessment by considering the details of the gas release event and slurry gas mixing as the gas is released from the waste. The consequences of postulated gas ignition are evaluated using a plume burn model and updated ignition frequency predictions. Tank pressurization which results from a gas burn, along with the structural response, is also considered. The report is intended to support the safety basis for work activities in flammable gas tanks by showing margins to safety limits that are available in the design and procedures.

  10. ROBOTIC TANK INSPECTION END EFFECTOR

    Energy Technology Data Exchange (ETDEWEB)

    Rachel Landry

    1999-10-01

    The objective of this contract between Oceaneering Space Systems (OSS) and the Department of Energy (DOE) was to provide a tool for the DOE to inspect the inside tank walls of underground radioactive waste storage tanks in their tank farms. Some of these tanks are suspected to have leaks, but the harsh nature of the environment within the tanks precludes human inspection of tank walls. As a result of these conditions only a few inspection methods can fulfill this task. Of the methods available, OSS chose to pursue Alternating Current Field Measurement (ACFM), because it does not require clean surfaces for inspection, nor any contact with the Surface being inspected, and introduces no extra by-products in the inspection process (no coupling fluids or residues are left behind). The tool produced by OSS is the Robotic Tank Inspection End Effector (RTIEE), which is initially deployed on the tip of the Light Duty Utility Arm (LDUA). The RTEE combines ACFM with a color video camera for both electromagnetic and visual inspection The complete package consists of an end effector, its corresponding electronics and software, and a user's manual to guide the operator through an inspection. The system has both coarse and fine inspection modes and allows the user to catalog defects and suspected areas of leakage in a database for further examination, which may lead to emptying the tank for repair, decommissioning, etc.. The following is an updated report to OSS document OSS-21100-7002, which was submitted in 1995. During the course of the contract, two related subtasks arose, the Wall and Coating Thickness Sensor and the Vacuum Scarifying and Sampling Tool Assembly. The first of these subtasks was intended to evaluate the corrosion and wall thinning of 55-gallon steel drums. The second was retrieved and characterized the waste material trapped inside the annulus region of the underground tanks on the DOE's tank farms. While these subtasks were derived from the original

  11. Effect of the foundation stiffness on the response of a seismically isolated tank under SSE conditions

    NARCIS (Netherlands)

    Esposito, G.; Courage, W.

    2003-01-01

    This paper presents the results of a feasibility study of a seismic isolated 120.000 m3 LNG tank. A simple model was used to evaluate the seismic response of the isolated tank under Safe Shutdown Earthquake conditions. The frequency dependent dynamic stiffness of the foundation was modele

  12. ANNUAL RADIOACTIVE WASTE TANK INSPECTION PROGRAM 2009

    Energy Technology Data Exchange (ETDEWEB)

    West, B.; Waltz, R.

    2010-06-21

    Aqueous radioactive wastes from Savannah River Site (SRS) separations and vitrification processes are contained in large underground carbon steel tanks. Inspections made during 2009 to evaluate these vessels and other waste handling facilities along with evaluations based on data from previous inspections are the subject of this report. The 2009 inspection program revealed that the structural integrity and waste confinement capability of the Savannah River Site waste tanks were maintained. All inspections scheduled per LWO-LWE-2008-00423, HLW Tank Farm Inspection Plan for 2009, were completed. All Ultrasonic measurements (UT) performed in 2009 met the requirements of C-ESG-00006, In-Service Inspection Program for High Level Waste Tanks, Rev. 1, and WSRC-TR-2002-00061, Rev.4. UT inspections were performed on Tank 29 and the findings are documented in SRNL-STI-2009-00559, Tank Inspection NDE Results for Fiscal Year 2009, Waste Tank 29. Post chemical cleaning UT measurements were made in Tank 6 and the results are documented in SRNL-STI-2009-00560, Tank Inspection NDE Results Tank 6, Including Summary of Waste Removal Support Activities in Tanks 5 and 6. A total of 6669 photographs were made and 1276 visual and video inspections were performed during 2009. Twenty-Two new leaksites were identified in 2009. The locations of these leaksites are documented in C-ESR-G-00003, SRS High Level Waste Tank Leaksite Information, Rev.4. Fifteen leaksites at Tank 5 were documented during tank wall/annulus cleaning activities. Five leaksites at Tank 6 were documented during tank wall/annulus cleaning activities. Two new leaksites were identified at Tank 19 during waste removal activities. Previously documented leaksites were reactivated at Tanks 5 and 12 during waste removal activities. Also, a very small amount of additional leakage from a previously identified leaksite at Tank 14 was observed.

  13. Performance of a solid oxide fuel cell CHP system coupled with a hot water storage tank for single household

    DEFF Research Database (Denmark)

    Liso, Vincenzo; Zhao, Yingru; Yang, Wenyuan

    2014-01-01

    of heat used for thermal loads of the residence. Two fuels are considered, namely syngas and natural gas. The tank model considers the temperature gradients over the tank height. The results of the numerical simulation is used to size the SOFC system and storage heat tank to provide energy for a small...... household using two different fuels. In particular it was shown that in the case of syngas, due to larger system heat output, a larger tank volume was required in order to accumulate unused heat over the night. The detailed description of the tank model will be useful to energy system modelers when sizing......In this paper a solid oxide fuel cell (SOFC) system for cogeneration of heat and power integrated with a stratified heat storage tank is studied. Thermal stratification in the tank increases the heat recovery performance as it allows existence of a temperature gradient with the benefit...

  14. Industrial thermoforming simulation of automotive fuel tanks

    Energy Technology Data Exchange (ETDEWEB)

    Wiesche, S. aus der [Kautex Textron GmbH and Co., Bonn (Germany)

    2004-11-01

    An industrial thermoforming simulation with regard to automotive plastic fuel tanks is presented including all relevant process stages. The radiative and conductive heat transfer during the reheat stage, the deformation and stress behaviour during the forming stage, and the final cooling stage are simulated. The modelling of the thermal and rheological behaviour of the involved material is investigated in greater detail. By means of experimental data it is found that modelling of the phase transition during the process is highly important for predicting correct wall thickness distributions. (author)

  15. Building and analyzing models from data by stirred tank experiments for investigation of matrix effects caused by inorganic matrices and selection of internal standards in Inductively Coupled Plasma-Atomic Emission Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Grotti, Marco [Dipartimento di Chimica e Chimica Industriale, Via Dodecaneso 31, 16146 Genova (Italy)], E-mail: grotti@chimica.unige.it; Paredes, Eduardo; Maestre, Salvador; Todoli, Jose Luis [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, 03080, Alicante (Spain)

    2008-05-15

    Interfering effects caused by inorganic matrices (inorganic acids as well as easily ionized elements) in inductively coupled plasma-atomic emission spectroscopy have been modeled by regression analysis of experimental data obtained using the 'stirred tank method'. The main components of the experimental set-up were a magnetically-stirred container and two peristaltic pumps. In this way the matrix composition was gradually and automatically varied, while the analyte concentration remained unchanged throughout the experiment. An inductively coupled plasma spectrometer with multichannel detection based on coupled charge device was used to simultaneously measure the emission signal at several wavelengths when the matrix concentration was modified. Up to 50 different concentrations were evaluated in a period of time of 10 min. Both single interfering species (nitric, hydrochloric and sulphuric acids, sodium and calcium) and different mixtures (aqua regia, sulfonitric mixture, sodium-calcium mixture and sodium-nitric acid mixture) were investigated. The dependence of the emission signal on acid concentration was well-fitted by logarithmic models. Conversely, for the easily ionized elements, 3-order polynomial models were more suitable to describe the trends. Then, the coefficients of these models were used as 'signatures' of the matrix-related signal variations and analyzed by principal component analysis. Similarities and differences among the emission lines were highlighted and discussed, providing a new insight into the interference phenomena, mainly with regards to the combined effect of concomitants. The combination of the huge amount of data obtained by the stirred tank method in a short period of time and the speed of analysis of principal component analysis provided a judicious means for the selection of the optimal internal standard in inductively coupled plasma-atomic emission spectroscopy.

  16. Organic tank safety project: Preliminary results of energetics and thermal behavior studies of model organic nitrate and/or nitrite mixtures and a simulated organic waste

    Energy Technology Data Exchange (ETDEWEB)

    Scheele, R.D.; Sell, R.L.; Sobolik, J.L.; Burger, L.L.

    1995-08-01

    As a result of years of production and recovery of nuclear defense materials and subsequent waste management at the Hanford Site, organic-bearing radioactive high-level wastes (HLW) are currently stored in large (up to 3. ML) single-shell storage tanks (SSTs). Because these wastes contain both fuels (organics) and the oxidants nitrate and nitrite, rapid energetic reactions at certain conditions could occur. In support of Westinghouse Hanford Company`s (WHC) efforts to ensure continued safe storage of these organic- and oxidant-bearing wastes and to define the conditions necessary for reactions to occur, we measured the thermal sensitivities and thermochemical and thermokinetic properties of mixtures of selected organics and sodium nitrate and/or nitrite and a simulated Hanford organic-bearing waste using thermoanalytical technologies. These thermoanalytical technologies are used by chemical reactivity hazards evaluation organizations within the chemical industry to assess chemical reaction hazards.

  17. Evolució històrica i models de think tanks a Catalunya : el cas de les fundacions dels partits polítics

    OpenAIRE

    Ponsa Herrera, Francesc

    2014-01-01

    Els think tanks ―fenomen essencialment nord-americà o, per extensió, anglosaxó― s’han estès en els països desenvolupats com actors polítics rellevants en la proposició i definició de polítiques públiques. A l’Estat espanyol, aquestes institucions no han adquirit el grau de desenvolupament dels països anglosaxons. Això es deu a diversos factors com la dictadura franquista, el nivell baix de finançament, el sistema mediàtic espanyol i la preponderància dels partits polítics. Aquest darrer facto...

  18. Thermal stratification in LH2 tank of cryogenic propulsion stage tested in ISRO facility

    Science.gov (United States)

    Xavier, M.; Raj, R. Edwin; Narayanan, V.

    2017-02-01

    Liquid oxygen and hydrogen are used as oxidizer and fuel respectively in cryogenic propulsion system. These liquids are stored in foam insulated tanks of cryogenic propulsion system and are pressurized using warm pressurant gas supplied for tank pressure maintenance during cryogenic engine operation. Heat leak to cryogenic propellant tank causes buoyancy driven liquid stratification resulting in formation of warm liquid stratum at liquid free surface. This warm stratum is further heated by the admission of warm pressurant gas for tank pressurization during engine operation. Since stratified layer temperature has direct bearing on the cavitation free operation of turbo pumps integrated in cryogenic engine, it is necessary to model the thermal stratification for predicting stratified layer temperature and mass of stratified liquid in tank at the end of engine operation. These inputs are required for estimating the minimum pressure to be maintained by tank pressurization system. This paper describes configuration of cryogenic stage for ground qualification test, stage hot test sequence, a thermal model and its results for a foam insulated LH2 tank subjected to heat leak and pressurization with hydrogen gas at 200 K during liquid outflow at 38 lps for engine operation. The above model considers buoyancy flow in free convection boundary layer caused by heat flux from tank wall and energy transfer from warm pressurant gas etc. to predict temperature of liquid stratum and mass of stratified liquid in tank at the end of engine operation in stage qualification tests carried out in ISRO facility.

  19. CHARACTERIZATION OF TANK 17 RESIDUAL WASTE

    Energy Technology Data Exchange (ETDEWEB)

    D' Entremont, P; Thomas Caldwell, T

    1997-09-22

    Plans are to close Tank 17, a type IV waste tank in the F-area Tank Farm, by filling it with pumpable backfills. Most of the waste was removed from the tank in the late 1980s, and the remainder of the waste was removed in a short spray washing campaign that began on 11 April 1997. More details on the planned closure can be found in the Closure Plan for the High-Level Waste (HLW) Tanks and the specific closure module for Tank 17. To show that closure of the tank is environmentally sound, a performance evaluation has been performed for Tank 17. The performance evaluation projected the concentration of contaminants at various locations and times after closure. This report documents the basis for the inventories of contaminants that were used in the Tank 17 performance evaluation.

  20. 241-AP Tank Farm Construction Extent of Condition Review for Tank Integrity

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, Travis J.; Gunter, Jason R.; Reeploeg, Gretchen E.

    2014-04-04

    This report provides the results of an extent of condition construction history review for the 241-AP tank farm. The construction history of the 241-AP tank farm has been reviewed to identify issues similar to those experienced during tank AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank AY-102 as the comparison benchmark. In the 241-AP tank farm, the sixth double-shell tank farm constructed, tank bottom flatness, refractory material quality, post-weld stress relieving, and primary tank bottom weld rejection were improved.

  1. 241-AY-101 Tank Construction Extent of Condition Review for Tank Integrity

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, Travis J.; Gunter, Jason R.

    2013-08-26

    This report provides the results of an extent of condition construction history review for tank 241-AY-101. The construction history of tank 241-AY-101 has been reviewed to identify issues similar to those experienced during tank AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank AY-102 as the comparison benchmark. In tank 241-AY-101, the second double-shell tank constructed, similar issues as those with tank 241-AY-102 construction reoccurred. The overall extent of similary and affect on tank 241-AY-101 integrity is described herein.

  2. 241-AW Tank Farm Construction Extent of Condition Review for Tank Integrity

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, Travis J.; Gunter, Jason R.; Reeploeg, Gretchen E.

    2013-11-19

    This report provides the results of an extent of condition construction history review for the 241-AW tank farm. The construction history of the 241-AW tank farm has been reviewed to identify issues similar to those experienced during tank AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank AY-102 as the comparison benchmark. In the 241-AW tank farm, the fourth double-shell tank farm constructed, similar issues as those with tank 241-AY-102 construction occured. The overall extent of similary and affect on 241-AW tank farm integrity is described herein.

  3. PILOT-SCALE TESTING OF THE SUSPENSION OF MST, CST, AND SIMULATED SLUDGE SLURRIES IN A SLUDGE TANK

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, M.; Qureshi, Z.; Restivo, M.; Steeper, T.; Williams, M.; Herman, D.

    2011-08-02

    The Small Column Ion Exchange (SCIX) process is being developed to remove cesium, strontium, and actinides from Savannah River Site (SRS) Liquid Waste using an existing waste tank (i.e., Tank 41H) to house the process. Following strontium, actinide, and cesium removal, the concentrated solids will be transported to a sludge tank (i.e., monosodium titanate (MST)/sludge solids to Tank 42H or Tank 51H and crystalline silicotitanate (CST) to Tank 40H) for eventual transfer to the Defense Waste Processing Facility (DWPF). Savannah River National Laboratory (SRNL) is conducting pilot-scale mixing tests to determine the pump requirements for mixing MST, CST, and simulated sludge. The purpose of this pilot scale testing is to determine the pump requirements for mixing MST and CST with sludge in a sludge tank and to determine whether segregation of particles occurs during settling. Tank 40H and Tank 51H have four Quad Volute pumps; Tank 42H has four standard pumps. The pilot-scale tank is a 1/10.85 linear scaled model of Tank 40H. The tank diameter, tank liquid level, pump nozzle diameter, pump elevation, and cooling coil diameter are all 1/10.85 of their dimensions in Tank 40H. The pump locations correspond to the current locations in Tank 40H (Risers B2, H, B6, and G). The pumps are pilot-scale Quad Volute pumps. Additional settling tests were conducted in a 30 foot tall, 4 inch inner diameter clear column to investigate segregation of MST, CST, and simulated sludge particles during settling.

  4. CFD simulation of particle suspension in a stirred tank

    Institute of Scientific and Technical Information of China (English)

    Nana Qi; Hu Zhang; Kai Zhang; Gang Xu; Yongping Yang

    2013-01-01

    Particle suspension characteristics are predicted computationally in a stirred tank driven by a Smith turbine.In order to verify the hydrodynamic model and numerical method,the predicted power number and flow pattern are compared with designed values and simulated results from the literature,respectively.The effects of particle density,particle diameter,liquid viscosity and initial solid loading on particle suspension behavior are investigated by using the Eulerian-Eulerian two-fluid model and the standard k-ε turbulence model.The results indicate that solid concentration distribution depends on the flow field in the stirred tank.Higher particle density or larger particle size results in less homogenous distribution of solid particles in the tank.Increasing initial solid loading has an adverse impact on the homogeneous suspension of solid particles in a low-viscosity liquid,whilst more uniform particle distribution is found in a high-viscositv liauid.

  5. The Influence of Holidays on Consumer's Purchasing Decision---Microeconomic Evidence from Non-seasonal Goods%节假日对消费者购买决策的影响--来自非季节性商品的微观证据

    Institute of Scientific and Technical Information of China (English)

    李国栋

    2013-01-01

    Different from existing literatures on China's holiday economy, this paper conducts a microeconometric study on the effect of holidays on consumer's purchasing behavior, with a focus on the influence of holidays on consumer's decisions on non-seasonal goods. Statistical analysis on the purchase records of representative non-seasonal goods shows that the demands do not increase evidently. Econometric analysis on consumer's purchase decisions using heteroscedastic probit model indicates that holidays alter consumer's price sensitivity significantly, but the directions are not the same between different goods. Firms should make a distinction between different goods when making holiday marketing strategy.%区别于研究我国假日经济的已有文献,采用零售扫描数据对消费者购买行为的假日效应进行微观实证研究,主要考察节假日对非季节性商品购买决策的影响。选取具有代表意义的非季节性商品的购买记录进行统计分析,发现其需求在节假日期间并没有明显增加;进一步通过异方差probit模型分析消费者的购买决策,结果表明节假日显著影响了消费者对价格的敏感度,但不同商品价格敏感度的变化方向并不一致。厂商制定节假日促销策略时应对不同的非季节性商品加以区分。

  6. Thermal Stratification in Small Solar Domestic Storage Tanks caused by Draw-offs

    DEFF Research Database (Denmark)

    Jordan, Ulrike; Furbo, Simon

    2005-01-01

    As shown in many research studies in the past, the thermal stratification of the tank caused by draw-offs has a high impact on the performance of a Solar Domestic Hot Water (SDHW) system. Nevertheless, in most tank models for system simulations the influence of the draw-off pattern on the mixing...... behaviour is not taken into account sufficiently. Two typical Danish domestic water storage tanks, each with a volume of about 150 l, were investigated. In both tanks the inlet pipes are placed at the bottom and hot water is drawn from the upper part of tank. Above the inlet pipes, differently shaped plates...... are placed in order to reduce the mixing of the incoming cold water with the warmer storage water. To measure the thermal stratification thermocouples were placed in a vertical glass tube inside the tank. Measurements were carried out with different draw-off volumes, flow rates, and initial temperatures...

  7. Multiple steady states in coupled flow tank reactors

    Science.gov (United States)

    Hunt, Katharine L. C.; Kottalam, J.; Hatlee, Michael D.; Ross, John

    1992-05-01

    Coupling between continuous-flow, stirred tank reactors (CSTR's), each having multiple steady states, can produce new steady states with different concentrations of the chemical species in each of the coupled tanks. In this work, we identify a kinetic potential ψ that governs the deterministic time evolution of coupled tank reactors, when the reaction mechanism permits a single-variable description of the states of the individual tanks; examples include the iodate-arsenous acid reaction, a cubic model suggested by Noyes, and two quintic models. Stable steady states correspond to minima of ψ, and unstable steady states to maxima or saddle points; marginally stable states typically correspond to saddle-node points. We illustrate the variation in ψ due to changes in the rate constant for external material intake (k0) and for exchange between tanks (kx). For fixed k0 values, we analyze the changes in numbers and types of steady states as kx increases from zero. We show that steady states disappear by pairwise coalescence; we also show that new steady states may appear with increasing kx, when the reaction mechanism is sufficiently complex. For fixed initial conditions, the steady state ultimately reached in a mixing experiment may depend on the exchange rate constant as a function of time, kx(t) : Adiabatic mixing is obtained in the limit of slow changes in kx(t) and instantaneous mixing in the limit as kx(t)→∞ while t remains small. Analyses based on the potential ψ predict the outcome of mixing experiments for arbitrary kx(t). We show by explicit counterexamples that a prior theory developed by Noyes does not correctly predict the instability points or the transitions between steady states of coupled tanks, to be expected in mixing experiments. We further show that the outcome of such experiments is not connected to the relative stability of steady states in individual tank reactors. We find that coupling may effectively stabilize the tanks. We provide

  8. Tank Waste Disposal Program redefinition

    Energy Technology Data Exchange (ETDEWEB)

    Grygiel, M.L.; Augustine, C.A.; Cahill, M.A.; Garfield, J.S.; Johnson, M.E.; Kupfer, M.J.; Meyer, G.A.; Roecker, J.H. [Westinghouse Hanford Co., Richland, WA (United States); Holton, L.K.; Hunter, V.L.; Triplett, M.B. [Pacific Northwest Lab., Richland, WA (United States)

    1991-10-01

    The record of decision (ROD) (DOE 1988) on the Final Environmental Impact Statement, Hanford Defense High-Level, Transuranic and Tank Wastes, Hanford Site, Richland Washington identifies the method for disposal of double-shell tank waste and cesium and strontium capsules at the Hanford Site. The ROD also identifies the need for additional evaluations before a final decision is made on the disposal of single-shell tank waste. This document presents the results of systematic evaluation of the present technical circumstances, alternatives, and regulatory requirements in light of the values of the leaders and constitutents of the program. It recommends a three-phased approach for disposing of tank wastes. This approach allows mature technologies to be applied to the treatment of well-understood waste forms in the near term, while providing time for the development and deployment of successively more advanced pretreatment technologies. The advanced technologies will accelerate disposal by reducing the volume of waste to be vitrified. This document also recommends integration of the double-and single-shell tank waste disposal programs, provides a target schedule for implementation of the selected approach, and describes the essential elements of a program to be baselined in 1992.

  9. Program plan for evaluation and remediation of the generation and release of flammable gases in Hanford Site waste tanks

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, G.D. (comp.)

    1991-08-01

    This program plan describes the activities being conducted for the resolution of the flammable gas problem that is associated with 23 high-level waste tanks at the Hanford Site. The classification of the wastes in all of these tanks is not final and some wastes may not be high-level wastes. However, until the characterization and classification is complete, all the tanks are treated as if they contain high-level waste. Of the 23 tanks, Tank 241-SY-101 (referred to as Tank 101-SY) has exhibited significant episodic releases of flammable gases (hydrogen and nitrous oxide) for the past 10 years. The major near-term focus of this program is for the understanding and stabilization of this tank. An understanding of the mechanism for gas generation and the processes for the episodic release will be obtained through sampling of the tank contents, laboratory studies, and modeling of the tank behavior. Additional information will be obtained through new and upgraded instrumentation for the tank. A number of remediation, or stabilization, concepts will be evaluated for near-term (2 to 3 years) applications to Tank 101-SY. Detailed safety assessments are required for all activities that will occur in the tank (sampling, removal of equipment, and addition of new instruments). This program plan presents a discussion of each task, provides schedules for near-term activities, and gives a summary of the expected work for fiscal years 1991, 1992, and 1993. 16 refs., 7 figs., 8 tabs.

  10. Effect of colloidal aggregation on the sedimentation and rheological properties of tank waste

    Energy Technology Data Exchange (ETDEWEB)

    Rector, D.R.; Bunker, B.C.

    1995-09-01

    Tank farm experience and work performed under the Tank Waste Treatment Science task of the Tank Waste Remediation System (TWRS) Pretreatment Technology Development Project indicate that colloidal interactions can have an enormous impact on tank waste processing. This report provides the theoretical and experimental background required to understand how such agglomeration phenomena control the sedimentation and theological behavior of colloidal tank wastes. First, the report describes the conditions under which the colloidal particles present in tank sludge are expected to aggregate. Computational models have been developed to predict solution conditions leading to agglomeration, and to predict the rate and size of aggregate growth. The models show that tank sludge should be heavily agglomerated under most baseline processing conditions. Second, the report describes models used to predict sedimentation rates and equilibrium sediment density profiles based on knowledge of agglomerate structures. The sedimentation models provide a self-consistent picture that explains the apparent discrepancies between bench-top experiments and tank-farm experience. Finally, both discrete and empirical models are presented that can be used to rationalize and predict the rheological properties of colloidal sludge suspensions. In all cases, model predictions are compared and contrasted with experimental results. The net results indicate that most of the observed behaviors of real sludges can be predicted, understood, and perhaps ultimately controlled by understanding a few key central concepts regarding agglomeration phenomena.

  11. Lightweight Tanks for Storing Liquefied Natural Gas

    Science.gov (United States)

    DeLay, Tom

    2008-01-01

    Single-walled, jacketed aluminum tanks have been conceived for storing liquefied natural gas (LNG) in LNG-fueled motor vehicles. Heretofore, doublewall steel tanks with vacuum between the inner and outer walls have been used for storing LNG. In comparison with the vacuum- insulated steel tanks, the jacketed aluminum tanks weigh less and can be manufactured at lower cost. Costs of using the jacketed aluminum tanks are further reduced in that there is no need for the vacuum pumps heretofore needed to maintain vacuum in the vacuum-insulated tanks.

  12. In-tank recirculating arsenic treatment system

    Science.gov (United States)

    Brady, Patrick V.; Dwyer, Brian P.; Krumhansl, James L.; Chwirka, Joseph D.

    2009-04-07

    A low-cost, water treatment system and method for reducing arsenic contamination in small community water storage tanks. Arsenic is removed by using a submersible pump, sitting at the bottom of the tank, which continuously recirculates (at a low flow rate) arsenic-contaminated water through an attached and enclosed filter bed containing arsenic-sorbing media. The pump and treatment column can be either placed inside the tank (In-Tank) by manually-lowering through an access hole, or attached to the outside of the tank (Out-of-Tank), for easy replacement of the sorption media.

  13. DEVELOPMENT OF A SMART SOLAR TANK

    DEFF Research Database (Denmark)

    Furbo, Simon; Andersen, Elsa

    1999-01-01

    Theoretical and experimental investigations of small SDHW systems based on so-called smart solar tanks are presented. A smart solar tank is a hot water tank in which the domestic water can both be heated by solar collectors and by an auxiliary energy supply system. The auxiliary energy supply....... The investigations showed that the yearly thermal performance of small SDHW systems can be increased by up to about 30 % if a smart solar tank is used instead of a traditional solar combi tank. The thermal increase is strongly influenced by the hot water consumption and consumption pattern. Recommendations...... for future development of smart solar tanks are given....

  14. CFD Extraction of Heat Transfer Coefficient in Cryogenic Propellant Tanks

    Science.gov (United States)

    Yang, H. Q.; West, Jeff

    2015-01-01

    Current reduced-order thermal model for cryogenic propellant tanks is based on correlations built for flat plates collected in the 1950's. The use of these correlations suffers from inaccurate geometry representation; inaccurate gravity orientation; ambiguous length scale; and lack of detailed validation. This study uses first-principles based CFD methodology to compute heat transfer from the tank wall to the cryogenic fluids and extracts and correlates the equivalent heat transfer coefficient to support reduced-order thermal model. The CFD tool was first validated against available experimental data and commonly used correlations for natural convection along a vertically heated wall. Good agreements between the present prediction and experimental data have been found for flows in laminar as well turbulent regimes. The convective heat transfer between the tank wall and cryogenic propellant, and that between the tank wall and ullage gas were then simulated. The results showed that the commonly used heat transfer correlations for either vertical or horizontal plate over-predict heat transfer rate for the cryogenic tank, in some cases by as much as one order of magnitude. A characteristic length scale has been defined that can correlate all heat transfer coefficients for different fill levels into a single curve. This curve can be used for the reduced-order heat transfer model analysis.

  15. Waste Tank Size Determination for the Hanford River Protection Project Cold Test, Training, and Mockup Facility

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Yasuo; Wells, Beric E.; Kuhn, William L.

    2001-03-30

    The objective of the study was to determine the minimum tank size for the Cold Test Facility process testing of Hanford tank waste. This facility would support retrieval of waste in 75-ft-diameter DSTs with mixer pumps and SSTs with fluidic mixers. The cold test model will use full-scale mixer pumps, transfer pumps, and equipment with simulated waste. The study evaluated the acceptability of data for a range of tank diameters and depths and included identifying how the test data would be extrapolated to predict results for a full-size tank.

  16. first tank of Linac 1

    CERN Multimedia

    This was the first tank of the linear accelerator Linac1, the injection system for the Proton Synchrotron, It ran for 34 years (1958 - 1992). Protons entered at the far end and were accelerated between the copper drift tubes by an oscillating electromagnetic field. The field flipped 200 million times a second (200 MHz) so the protons spent 5 nanoseconds crossing a drift tube and a gap. Moving down the tank, the tubes and gaps had to get longer as the protons gained speed. The tank accelerated protons from 500 KeV to 10 MeV. Linac1 was also used to accelerate deutrons and alpha particles for the Intersecting Storage Rings and oxygen and sulpher ions for the Super Proton Synchrotron heavy ion programme.

  17. Small Tank Tetraphenylborate Catalyst Studies

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, M.J.

    2001-06-04

    The Salt Disposition Systems Engineering Team identified Small Tank Tetraphenylborate Precipitation (STTP) as an alternative to replace the In-Tank Precipitation Facility at the Savannah River Site. The Department of Energy discontinued operation of the In-Tank Precipitation facility due to the potential for catalytic decomposition of sodium tetraphenylborate. The STTP applies the same process chemistry for removal of cesium from the radioactive wastes but at a controlled lower temperature and in a smaller facility that offers engineering features to mitigate potential for a catalytic reaction. However, additional understanding of the catalytic reaction, through further experimental investigation, is needed to better define the potential for a reaction to occur in the proposed facility.

  18. ICPP Tank Farm systems analysis

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, W.B.; Beer, M.J.; Cukars, M.; Law, J.P.; Millet, C.B.; Murphy, J.A.; Nenni, J.A.; Park, C.V.; Pruitt, J.I.; Thiel, E.C.; Ward, F.S.; Woodard, J.

    1994-01-01

    During the early years (1950--1965) of Idaho Chemical Processing Plant (ICPP) operations, eleven, 300,000-gallon waste storage tanks were constructed. A project was in progress to replace these aging tanks; however, since fuel reprocessing has been curtailed at ICPP, it is not clear that the new tanks are required. The Department of Energy (DOE) requested a systems engineering evaluation to determine the need for the new tanks. Over 100 alternatives were identified during a facilitated team meeting using Value Engineering techniques. After eliminating any ideas which clearly could not meet the requirements, the remaining ideas were combined into nine basic cases with five sub cases. These fourteen cases were then carefully defined using two methods. First, each case was drawn graphically to show waste processing equipment interfaces and time constraints where they existed or were imposed. Second, each case was analyzed using a time-dependent computer simulation of ICPP waste management activities to determine schedule interactions, liquid storage requirements, and solid waste quantities. Based on the evaluation data, the team developed the following recommendations: Install and operate the high-level liquid waste evaporator; minimize liquid waste generation as much as possible within the constraints of required ICPP operational, safety, and environmental commitments; bring a Waste Immobilization Facility on line by 2008 or earlier; operate NWCF as required to alleviate the need for new tank farm capacity; maximize the concentration of Na and K in the calcine to minimize the final amount of waste requiring immobilization; avoid using Bin Set 7 for calcine storage, if possible, to reduce future calcine retrieval and D&D costs; and use WM-190 for liquid waste storage and one of the pillar and panel vaulted tanks as the spare.

  19. Tank calibration; Arqueacao de tanques

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Ana [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    This work relates the analysis of the norms ISO (International Organization for Standardization) for calibration of vertical cylindrical tanks used in fiscal measurement, established on Joint Regulation no 1 of June 19, 2000 between the ANP (National Agency of Petroleum) and the INMETRO (National Institute of Metrology, Normalization and Industrial Quality). In this work a comparison between norms ISO and norms published by the API (American Petroleum Institute) and the IP (Institute of Petroleum) up to 2001 was made. It was concluded that norms ISO are wider than norms API, IP, and INMETRO methods in the calibration of vertical cylindrical tanks. (author)

  20. TANK SPACE ALTERNATIVES ANALYSIS REPORT

    Energy Technology Data Exchange (ETDEWEB)

    TURNER DA; KIRCH NW; WASHENFELDER DJ; SCHAUS PS; WODRICH DD; WIEGMAN SA

    2010-04-27

    This report addresses the projected shortfall of double-shell tank (DST) space starting in 2018. Using a multi-variant methodology, a total of eight new-term options and 17 long-term options for recovering DST space were evaluated. These include 11 options that were previously evaluated in RPP-7702, Tank Space Options Report (Rev. 1). Based on the results of this evaluation, two near-term and three long-term options have been identified as being sufficient to overcome the shortfall of DST space projected to occur between 2018 and 2025.

  1. Out-of-tank evaporator demonstration: Tanks focus area

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-01

    Approximately 100 million gal of liquid waste is stored in underground storage tanks (UST)s at the Hanford Site, Idaho National Engineering and Environmental Laboratory (INEEL), Savannah River Site (SRS), and Oak Ridge Reservation (ORR). This waste is radioactive with a high salt content. The US Department of Energy (DOE) wants to minimize the volume of radioactive liquid waste in USTs by removing the excess water. This procedure conserves tank space; lowers the cost of storage; and reduces the volume of wastes subsequently requiring separation, immobilization, and disposal. The Out-of-Tank Evaporator Demonstration (OTED) was initiated to test a modular, skid-mounted evaporator. A mobile evaporator system manufactured by Delta Thermal Inc. was selected. The evaporator design was routinely used in commercial applications such as concentrating metal-plating wastes for recycle and concentrating ethylene glycol solutions. In FY 1995, the skid-mounted evaporator system was procured and installed in an existing ORNL facility (Building 7877) with temporary shielding and remote controls. The evaporator system was operational in January 1996. The system operated 24 h/day and processed 22,000 gal of Melton Valley Storage Tank (MVST) supernatant. The distillate contained essentially no salts or radionuclides. Upon completion of the demonstration, the evaporator underwent decontamination testing to illustrate the feasibility of hands-on maintenance and potential transport to another DOE facility. This report describes the process and the evaporator, its performance at ORNL, future plans, applications of this technology, cost estimates, regulatory and policy considerations, and lessons learned.

  2. Leaking Underground Storage Tank (LUST) Trust Fund

    Science.gov (United States)

    In 1986, Congress created the Leaking Underground Storage Tank (LUST) Trust Fund to address releases from federally regulated underground storage tanks (USTs) by amending Subtitle I of the Solid Waste Disposal Act.

  3. Lightweight, Composite Cryogenic Tank Structures Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Microcosm has developed and qualified strong, all-composite LOX tanks for launch vehicles. Our new 42-inch diameter tank design weighs 486 lbs and burst without...

  4. Comparative safety analysis of LNG storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    Fecht, B.A.; Gates, T.E.; Nelson, K.O.; Marr, G.D.

    1982-07-01

    LNG storage tank design and response to selected release scenarios were reviewed. The selection of the scenarios was based on an investigation of potential hazards as cited in the literature. A review of the structure of specific LNG storage facilities is given. Scenarios initially addressed included those that most likely emerge from the tank facility itself: conditions of overfill and overflow as related to liquid LNG content levels; over/underpressurization at respective tank vapor pressure boundaries; subsidence of bearing soil below tank foundations; and crack propagation in tank walls due to possible exposure of structural material to cryogenic temperatures. Additional scenarios addressed include those that result from external events: tornado induced winds and pressure drops; exterior tank missile impact with tornado winds and rotating machinery being the investigated mode of generation; thermal response due to adjacent fire conditions; and tank response due to intense seismic activity. Applicability of each scenario depended heavily on the specific tank configurations and material types selected. (PSB)

  5. Model of the identification of oil tank’s position and the calibration of tank capacity table%储油罐的变位识别与罐容表标定模型

    Institute of Scientific and Technical Information of China (English)

    窦霁虹; 梅钰; 陈振勋; 王莉莉

    2011-01-01

    The identification of oil tank’s position and the calibration of tank capacity table were studied.First,the functions of the oil storage and the oil height were inferred when the oil tank position was not changed and was tilted,and two remedy methods of the error were devised.Second,by using remedy methods,the cubic polynomial of the oil height was fitted when the oil’s volume and the systematic error were seen as a whole,then the non-linear optimization model with tilt and deflection was found by using the least squares.Last,according to the real date,the parameters of tilt and deflection were obtained by using searching algorithm,those were α = 4.4,β = 4.9.The tank capacity table was given when the interval was 10 cm,and the part of data was examined.%用数学建模方法试图研究解决储油罐变位识别与罐容表标定问题.首先精确推导了无变位以及纵向倾斜时罐内储油量与油位高度的函数关系,且设计了两种系统误差补偿方法.一种是基于等效思想的δ值法,另一种拟合法.其次,确定变位参数时依然使用补偿思想,将球冠体部分的储油体积和系统误差统一为整体拟合成油位高度h的三次多项式,并应用最小二乘原理建立了同时具有纵向倾斜和横向偏转变位参数的非线性优化模型.最后利用搜索算法得到由实际储油罐的实测数据确定的变位参数α=4.4,β=4.9,将其代入建立的罐容表标定模型,给定油位间隔10 cm,得到了所需罐容表标定值,并利用相关文献中的部分数据进行了检验.

  6. Thermal destratification in small standard solar tanks due to mixing during tapping

    DEFF Research Database (Denmark)

    Andersen, Elsa; Furbo, Simon

    1999-01-01

    The aim of the project is to investigate the thermal destratification in small standard solar tanks due to mixing during tapping. Three different cold water inlet designs are tested. A model of the tested solar tank is verified. Based on the measurements and the calculations it is elucidated how...

  7. STEADY STATE FLAMMABLE GAS RELEASE RATE CALCULATION & LOWER FLAMMABILITY LEVEL EVALUATION FOR HANFORD TANK WASTE

    Energy Technology Data Exchange (ETDEWEB)

    HU, T.A.

    2005-10-27

    Assess the steady-state flammability level at normal and off-normal ventilation conditions. The hydrogen generation rate was calculated for 177 tanks using the rate equation model. Flammability calculations based on hydrogen, ammonia, and methane were performed for 177 tanks for various scenarios.

  8. STEADY STATE FLAMMABLE GAS RELEASE RATE CALCULATION AND LOWER FLAMMABILITY LEVEL EVALUATION FOR HANFORD TANK WASTE

    Energy Technology Data Exchange (ETDEWEB)

    HU TA

    2009-10-26

    Assess the steady-state flammability level at normal and off-normal ventilation conditions. The hydrogen generation rate was calculated for 177 tanks using the rate equation model. Flammability calculations based on hydrogen, ammonia, and methane were performed for 177 tanks for various scenarios.

  9. Stabilization of Parametric Roll Resonance with Active U-Tanks via Lyapunov Control Design

    DEFF Research Database (Denmark)

    Holden, Christian; Galeazzi, Roberto; Fossen, Thor Inge;

    2009-01-01

    design of an active u-tank stabilizer is carried out using Lyapunov theory. A nonlinear backstepping controller is developed to provide global exponential stability of roll. An extension of commonly used u-tank models is presented to account for large roll angles, and the control design is tested via...

  10. Regional scale analysis for the design of storage tanks for domestic rainwater harvesting systems.

    Science.gov (United States)

    Campisano, A; Modica, C

    2012-01-01

    A regional scale analysis for the design of storage tanks for domestic rain water harvesting systems is presented. The analysis is based on the daily water balance simulation of the storage tank by the yield-after-spillage algorithm as tank release rule. Water balances are applied to 17 rainfall gauging stations in Sicily (Italy). Compared with literature existing methods, a novel dimensionless parameter is proposed to better describe the intra-annual character of the rainfall patterns. As a result, easy-to-use regional regressive models to evaluate the water saving performance and the overflow discharges from the tank are provided along with a stepwise procedure for practical application. The regional models demonstrate good fits between model predictions and simulated values of both water savings and overflows from the tank.

  11. 49 CFR 179.400 - General specification applicable to cryogenic liquid tank car tanks.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false General specification applicable to cryogenic... MATERIALS REGULATIONS SPECIFICATIONS FOR TANK CARS Specification for Cryogenic Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.400 General specification applicable to cryogenic...

  12. Chemical speciation of strontium, americium, and curium in high level waste: Predictive modeling of phase partitioning during tank processing. Annual progress report, October 1996--September 1997

    Energy Technology Data Exchange (ETDEWEB)

    Felmy, A.R. [Pacific Northwest National Lab., Richland, WA (US); Choppin, G. [Florida State Univ., Tallahassee, FL (US)

    1997-12-31

    'The program at Florida State University was funded to collaborate with Dr. A. Felmy (PNNL) on speciation in high level wastes and with Dr. D. Rai (PNNL) on redox of Pu under high level waste conditions. The funding provided support for 3 research associates (postdoctoral researchers) under Professor G. R. Choppin as P.I. Dr. Kath Morris from U. Manchester (Great Britain), Dr. Dean Peterman and Dr. Amy Irwin (both from U. Cincinnati) joined the laboratory in the latter part of 1996. After an initial training period to become familiar with basic actinide chemistry and radiochemical techniques, they began their research. Dr. Peterman was assigned the task of measuring Th-EDTA complexation prior to measuring Pu(IV)-EDTA complexation. These studies are associated with the speciation program with Dr. Felmy. Drs. Morris and Irwin initiated research on redox of plutonium with agents present in the Hanford Tanks as a result of radiolysis or from use in separations. The preliminary results obtained thus far are described in this report. It is expected that the rate of progress will continue to increase significantly as the researchers gain more experience with plutonium chemistry.'

  13. Planning the Safety of Atrial Fibrillation Ablation Registry Initiative (SAFARI) as a Collaborative Pan-Stakeholder Critical Path Registry Model: a Cardiac Safety Research Consortium "Incubator" Think Tank.

    Science.gov (United States)

    Al-Khatib, Sana M; Calkins, Hugh; Eloff, Benjamin C; Packer, Douglas L; Ellenbogen, Kenneth A; Hammill, Stephen C; Natale, Andrea; Page, Richard L; Prystowsky, Eric; Jackman, Warren M; Stevenson, William G; Waldo, Albert L; Wilber, David; Kowey, Peter; Yaross, Marcia S; Mark, Daniel B; Reiffel, James; Finkle, John K; Marinac-Dabic, Danica; Pinnow, Ellen; Sager, Phillip; Sedrakyan, Art; Canos, Daniel; Gross, Thomas; Berliner, Elise; Krucoff, Mitchell W

    2010-01-01

    Atrial fibrillation (AF) is a major public health problem in the United States that is associated with increased mortality and morbidity. Of the therapeutic modalities available to treat AF, the use of percutaneous catheter ablation of AF is expanding rapidly. Randomized clinical trials examining the efficacy and safety of AF ablation are currently underway; however, such trials can only partially determine the safety and durability of the effect of the procedure in routine clinical practice, in more complex patients, and over a broader range of techniques and operator experience. These limitations of randomized trials of AF ablation, particularly with regard to safety issues, could be addressed using a synergistically structured national registry, which is the intention of the SAFARI. To facilitate discussions about objectives, challenges, and steps for such a registry, the Cardiac Safety Research Consortium and the Duke Clinical Research Institute, Durham, NC, in collaboration with the US Food and Drug Administration, the American College of Cardiology, and the Heart Rhythm Society, organized a Think Tank meeting of experts in the field. Other participants included the National Heart, Lung and Blood Institute, the Centers for Medicare and Medicaid Services, the Agency for Healthcare Research and Quality, the Society of Thoracic Surgeons, the AdvaMed AF working group, and additional industry representatives. The meeting took place on April 27 to 28, 2009, at the US Food and Drug Administration headquarters in Silver Spring, MD. This article summarizes the issues and directions presented and discussed at the meeting. Copyright 2010 Mosby, Inc. All rights reserved.

  14. Developing the Safety of Atrial Fibrillation Ablation Registry Initiative (SAFARI) as a collaborative pan-stakeholder critical path registry model: a Cardiac Safety Research Consortium "Incubator" Think Tank.

    Science.gov (United States)

    Al-Khatib, Sana M; Calkins, Hugh; Eloff, Benjamin C; Kowey, Peter; Hammill, Stephen C; Ellenbogen, Kenneth A; Marinac-Dabic, Danica; Waldo, Albert L; Brindis, Ralph G; Wilbur, David J; Jackman, Warren M; Yaross, Marcia S; Russo, Andrea M; Prystowsky, Eric; Varosy, Paul D; Gross, Thomas; Pinnow, Ellen; Turakhia, Mintu P; Krucoff, Mitchell W

    2010-10-01

    Although several randomized clinical trials have demonstrated the safety and efficacy of catheter ablation of atrial fibrillation (AF) in experienced centers, the outcomes of this procedure in routine clinical practice and in patients with persistent and long-standing persistent AF remain uncertain. Brisk adoption of this therapy by physicians with diverse training and experience highlights potential concerns regarding the safety and effectiveness of this procedure. Some of these concerns could be addressed by a national registry of AF ablation procedures such as the Safety of Atrial Fibrillation Ablation Registry Initiative that was initially proposed at a Cardiac Safety Research Consortium Think Tank meeting in April 2009. In January 2010, the Cardiac Safety Research Consortium, in collaboration with the Duke Clinical Research Institute, the US Food and Drug Administration, the American College of Cardiology, and the Heart Rhythm Society, held a follow-up meeting of experts in the field to review the construct and progress to date. Other participants included the National Heart, Lung, and Blood Institute; the Centers for Medicare and Medicaid Services; the Agency for Healthcare Research and Quality; the AdvaMed AF working group; and additional industry representatives. This article summarizes the discussions that occurred at the meeting of the state of the Safety of Atrial Fibrillation Ablation Registry Initiative, the identification of a clear pathway for its implementation, and the exploration of solutions to potential issues in the execution of this registry. Copyright © 2010 Mosby, Inc. All rights reserved.

  15. Design of an Experimental PCM Solar Tank

    Energy Technology Data Exchange (ETDEWEB)

    Szabo, Istvan Peter

    2010-09-15

    The one of the most important part of a solar collector system is the solar tank. The relevant type and capacity of the solar tank is a requirement of the good operation of the system. According the current architectural tendencies the boiler rooms are smaller, so the putting of the currently available solar tanks is very difficult. It is necessary to store the energy in a little space. The solution of the problem is the solar tank particularly filled with phase change material.

  16. Results of Hg speciation testing on tank 39 and 1Q16 tank 50 samples

    Energy Technology Data Exchange (ETDEWEB)

    Bannochie, C. J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-03-07

    The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team.i,ii The seventeenth shipment of samples was designated to include two Tank 39 samples and the 1Q16 Tank 50 Quarterly WAC sample. The surface Tank 39 sample was pulled at 262.1” from the tank bottom, and the depth Tank 39 sample was pulled at 95” from the tank bottom. The 1Q16 Tank 50 WAC sample was drawn from the 1-L variable depth sample received by SRNL.

  17. Thermal stratification in a hot water tank established by heat loss from the tank

    DEFF Research Database (Denmark)

    on the natural buoyancy resulting in downward flow along the tank side walls due to heat loss of the tank and the influence on thermal stratification of the tank by the downward flow and the corresponding upward flow in the central parts of the tank. Water temperatures at different levels of the tank......Results of experimental and numerical investigations of thermal stratification and natural convection in a vertical cylindrical hot water tank during standby periods are presented. The transient fluid flow and heat transfer in the tank during cooling caused by heat loss are investigated...

  18. Thermal stratification in a hot water tank established by heat loss from the tank

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2009-01-01

    on the natural buoyancy resulting in downward flow along the tank side walls due to heat loss of the tank and the influence on thermal stratification of the tank by the downward flow and the corresponding upward flow in the central parts of the tank. Water temperatures at different levels of the tank......Results of experimental and numerical investigations of thermal stratification and natural convection in a vertical cylindrical hot water tank during standby periods are presented. The transient fluid flow and heat transfer in the tank during cooling caused by heat loss are investigated...

  19. Tank 241-BY-107 vapor sampling and analysis tank characterization report

    Energy Technology Data Exchange (ETDEWEB)

    Huckaby, J.L.

    1995-05-05

    Tank 241-BY-107 headspace gas and vapor samples were collected and analyzed to help determine the potential risks to tank farm workers due to fugitive emissions from the tank. The drivers and objectives of waste tank headspace sampling and analysis are discussed in {open_quotes}Program Plan for the Resolution of Tank Vapor Issues{close_quotes}. Tank 241-BY-107 was vapor sampled in accordance with {open_quotes}Data Quality Objectives for Generic In-Tank Health and Safety Issue Resolution{close_quotes}.

  20. Tank 241-BY-107 vapor sampling and analysis tank characterization report. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Huckaby, J.L.

    1995-05-31

    Tank 241-BY-107 headspace gas and vapor samples were collected and analyzed to help determine the potential risks to tank farm workers due to fugitive emissions from the tank. The drivers and objectives of waste tank headspace sampling and analysis are discussed in {open_quotes}Program Plan for the Resolution of Tank Vapor Issues.{close_quotes} Tank 241-BY-107 was vapor sampled in accordance with {open_quotes}Data Quality Objectives for Generic In-Tank Health and Safety Issue Resolution.{close_quotes}

  1. Tank 241-BY-108 vapor sampling and analysis tank characterization report. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Huckaby, J.L.

    1995-05-31

    Tank 241-BY-108 headspace gas and vapor samples were collected and analyzed to help determine the potential risks to tank farm workers due to fugitive emissions from the tank. The drivers and objectives of waste tank headspace sampling and analysis are discussed in ``Program Plan for the Resolution of Tank Vapor Issues`` (Osborne and Huckaby 1994). Tank 241-BY-108 was vapor sampled in accordance with ``Data Quality Objectives for Generic In-Tank Health and Safety Issue Resolution (Osborne et al., 1994).

  2. 27 CFR 19.382 - Bottling tanks.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Bottling tanks. 19.382... Manufacture of Articles Bottling, Packaging, and Removal of Products § 19.382 Bottling tanks. All spirits shall be bottled from tanks listed and certified as accurately calibrated in the notice of...

  3. 33 CFR 183.510 - Fuel tanks.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Fuel tanks. 183.510 Section 183... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.510 Fuel tanks. (a) Each fuel tank in a boat must have been tested by its manufacturer under § 183.580 and not leak...

  4. 27 CFR 19.273 - Tanks.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Tanks. 19.273 Section 19... TREASURY LIQUORS DISTILLED SPIRITS PLANTS Construction, Equipment and Security § 19.273 Tanks. (a) General. (1) Tanks used as receptacles for spirits, denatured spirits, or wines shall be located,...

  5. 27 CFR 19.586 - Tanks.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Tanks. 19.586 Section 19.586 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS DISTILLED SPIRITS PLANTS Containers and Marks Containers § 19.586 Tanks. Tanks...

  6. 49 CFR 172.328 - Cargo tanks.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Cargo tanks. 172.328 Section 172.328... SECURITY PLANS Marking § 172.328 Cargo tanks. (a) Providing and affixing identification numbers. Unless a cargo tank is already marked with the identification numbers required by this subpart,...

  7. 7 CFR 58.427 - Paraffin tanks.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Paraffin tanks. 58.427 Section 58.427 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....427 Paraffin tanks. The metal tank should be adequate in size, have wood rather than metal racks...

  8. 49 CFR 172.326 - Portable tanks.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Portable tanks. 172.326 Section 172.326... SECURITY PLANS Marking § 172.326 Portable tanks. (a) Shipping name. No person may offer for transportation or transport a portable tank containing a hazardous material unless it is legibly marked on...

  9. 19 CFR 151.44 - Storage tanks.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Storage tanks. 151.44 Section 151.44 Customs... Storage tanks. (a) Plans and gauge tables. When petroleum or petroleum products subject to duty at a specific rate per barrel are imported in bulk in tank vessels and are to be transferred into shore...

  10. Opposed Bellows Would Expel Contents Of Tank

    Science.gov (United States)

    Whitaker, Willie

    1994-01-01

    Proposed storage tank contains two pairs of opposed bellows used to expel its contents. Storage and expulsion volumes of tank same as those of older version of tank equipped with single bellows. Four bellows offer greater stability. Applications include automobile cooling systems and gasoline-powered tools like chain saws and leaf blowers.

  11. Think Tanks, Education and Elite Policy Actors

    Science.gov (United States)

    Savage, Glenn C.

    2016-01-01

    The past decade has seen think tanks operate in sophisticated ways to influence the development of education policies. In this paper, I reflect upon the influence of think tanks in the formation of national reform, using the Common Core State Standards initiative in the USA as an illustrative case. In doing so, I explore how certain think tanks,…

  12. Tank 12H residuals sample analysis report

    Energy Technology Data Exchange (ETDEWEB)

    Oji, L. N. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Shine, E. P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Diprete, D. P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Coleman, C. J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hay, M. S. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-06-11

    The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 12H final characterization samples to determine the residual tank inventory prior to grouting. Eleven Tank 12H floor and mound residual material samples and three cooling coil scrape samples were collected and delivered to SRNL between May and August of 2014.

  13. 49 CFR 230.115 - Feed water tanks.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Feed water tanks. 230.115 Section 230.115... Tenders Steam Locomotive Tanks § 230.115 Feed water tanks. (a) General provisions. Tanks shall be... for tank wells or tank hose and shall be maintained in a manner that allows the unobstructed flow...

  14. 33 CFR 157.218 - Dedicated clean ballast tanks: Alterations.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Dedicated clean ballast tanks... CARRYING OIL IN BULK Dedicated Clean Ballast Tanks on Tank Vessels General § 157.218 Dedicated clean ballast tanks: Alterations. The dedicated clean ballast tanks or equipment on a tank vessel that has...

  15. Tank characterization report for double-shell tank 241-AP-102

    Energy Technology Data Exchange (ETDEWEB)

    LAMBERT, S.L.

    1999-02-23

    In April 1993, Double-Shell Tank 241-AP-102 was sampled to determine waste feed characteristics for the Hanford Grout Disposal Program. This Tank Characterization Report presents an overview of that tank sampling and analysis effort, and contains observations regarding waste characteristics, expected bulk inventory, and concentration data for the waste contents based on this latest sampling data and information on the history of the tank. Finally, this report makes recommendations and conclusions regarding tank operational safety issues.

  16. 基于云模型的水箱液位控制系统的设计与实现%Design and Realization of a Tank Liquid Lever Control System Based on the Cloud Model

    Institute of Scientific and Technical Information of China (English)

    李众; 李军; 王海波

    2012-01-01

    A tank liquid lever control system based on cloud model is designed and implemented. The site part of the A3000 process control systerm as the hardware platform, hybrid programming of VB and Matlab achieving the software, the Kingview collecting and displaying date, DDE transforming date are used. In the absence of establish the precise mathematical model of the case, the effect and the robustness of the cloud model controller to are veri-fyed. The experimental results on cloud model theory research as well as industrial control field has certain reference significance.%设计并实现了水箱水位的云模型控制系统.以A3000过程控制系统的现场部分为硬件平台,软件采用VB与Matlab的混合编程,组态采集数据及数据显示.数据传输方式采用DDE通讯技术.验证了云模型控制器在没有建立精确数学模型的情况下的控制效果.验证了云模型控制器的鲁棒性.实验结果对云模型的理论研究以及工业控制现场具有一定的参考意义.

  17. Study of characteristics of gas holdup in stirred tank under three turbulence models%三种湍流模型下搅拌釜内气含率特性的模拟

    Institute of Scientific and Technical Information of China (English)

    丁程兵; 陈迁乔; 钟秦

    2013-01-01

    采用计算流体力学(CFD)方法,应用Euler-Euler双流体模型,桨叶采用多重参考系法(MFR),与考虑气泡聚并与破碎对气泡尺寸影响的群体平衡模型(PBM)相结合,比较了标准k-ε、Realizable k-ε和RNG k-ε3种湍流模型对双层涡轮搅拌釜内气-液两相液相流场、局部气含率及气泡尺寸分布的影响。结果表明:3种湍流模型预测的液相流场流型相似,总体气含率预测值相差不大,均与实验值吻合较好。对于局部气含率,标准k-ε和RNG k-ε模型在桨叶区的预测值偏大,在接近自由液面处三者预测值均偏低,Realizable k-ε模型预测结果与实验值符合最好;对于气泡尺寸,3种湍流模型预测结果均与实验值较吻合,在靠近自由液面处预测值均偏小,气泡尺寸分布与湍流长度分布相吻合。%This paper investigated the simulation of liquid velocity, local gas holdup and bubble size in a stirred tank with dual turbine impellers using computational fluid dynamics(CFD). The results from three different turbulence models (Standard k-ε,RNG k-ε,Realizable k-ε) were compared. The Euler-Euler multiphase flow model and multiple frames of reference(MFR) method were used in the simulations. A population balance model(PBM) was implemented in order to account for the combined effect of bubble break-up and coalescence in the tank. The results showed that the flow patterns of liquid phase and the total gas holdups predicted by the three models had no significant difference, and the total gas holdups agreed well with the experimental data. The standard k-ε and RNG k-ε models over predicted the local gas holdup values at the impeller regions, and in the upper part of the vessel near the liquid-free surface where the local gas holdups predicted all were lower than the measurements. The realizable k-ε model gave the best result compared with the experimental data. The simulated results and

  18. 33 CFR 157.206 - Dedicated Clean Ballast Tanks Operations Manual for U.S. tank vessels: Submission.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Dedicated Clean Ballast Tanks... MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Dedicated Clean Ballast Tanks on Tank Vessels General § 157.206 Dedicated Clean Ballast Tanks Operations Manual for U.S. tank...

  19. 33 CFR 157.10b - Segregated ballast tanks, dedicated clean ballast tanks, and special ballast arrangements for...

    Science.gov (United States)

    2010-07-01

    ..., dedicated clean ballast tanks, and special ballast arrangements for tank vessels transporting Outer..., dedicated clean ballast tanks, and special ballast arrangements for tank vessels transporting Outer..., 1980 must, if segregated ballast tanks or dedicated clean ballast tanks are not required under §...

  20. An approximate-reasoning-based method for screening flammable gas tanks

    Energy Technology Data Exchange (ETDEWEB)

    Eisenhawer, S.W.; Bott, T.F.; Smith, R.E.

    1998-03-01

    High-level waste (HLW) produces flammable gases as a result of radiolysis and thermal decomposition of organics. Under certain conditions, these gases can accumulate within the waste for extended periods and then be released quickly into the dome space of the storage tank. As part of the effort to reduce the safety concerns associated with flammable gas in HLW tanks at Hanford, a flammable gas watch list (FGWL) has been established. Inclusion on the FGWL is based on criteria intended to measure the risk associated with the presence of flammable gas. It is important that all high-risk tanks be identified with high confidence so that they may be controlled. Conversely, to minimize operational complexity, the number of tanks on the watchlist should be reduced as near to the true number of flammable risk tanks as the current state of knowledge will support. This report presents an alternative to existing approaches for FGWL screening based on the theory of approximate reasoning (AR) (Zadeh 1976). The AR-based model emulates the inference process used by an expert when asked to make an evaluation. The FGWL model described here was exercised by performing two evaluations. (1) A complete tank evaluation where the entire algorithm is used. This was done for two tanks, U-106 and AW-104. U-106 is a single shell tank with large sludge and saltcake layers. AW-104 is a double shell tank with over one million gallons of supernate. Both of these tanks had failed the screening performed by Hodgson et al. (2) Partial evaluations using a submodule for the predictor likelihood for all of the tanks on the FGWL that had been flagged previously by Whitney (1995).

  1. Design and Implementation of the MSL Cruise Propulsion Tank Heaters

    Science.gov (United States)

    Krylo, Robert; Mikhaylov, Rebecca; Cucullu, Gordon; Watkins, Brenda

    2008-01-01

    This slide presentation reviews the design and the implementation of the heaters for the Mars Science Laboratory (MSL). The pressurized tanks store hydrazine that freezes at 2 C, this means that heaters are required to keep the hydrazine and the helium at 36 C for the trip to Mars. Using the TMG software the heat loss was analyzed, and a thermal model simulates a half full tank which yielded a 13W heating requirement for each hemisphere. Views of the design, and the heater are included.

  2. CORRELATION OF EXPERIMENTAL AND THEORETICAL DATA FOR MANTLE TANKS USED IN LOW FLOW SDHW SYSTEMS

    DEFF Research Database (Denmark)

    Shah, Louise Jivan; Furbo, Simon

    1997-01-01

    Experimental and theoretical investigations of mantle tanks for SDHW systems have been carried out. Five differently designed mantle tanks have been tested in a laboratory test facility. A transient three-dimensional CFD-model of one of the tested mantle tanks is made in the CFD-program CFX 4.......1. The model is validated against the experimental tests, and good agreement between measured and calculated results is achieved. The results from the CFD-calculations are used to illustrate the thermal behaviour and the fluid dynamics in the mantle and in the hot water tank. With the CFD......-calculations, a detailed analysis of the heat transfer from the solar collector fluid to the wall of the hot water tank is performed. The analysis has resulted in a correlation for the heat transfer between the solar collector fluid and the wall of the hot water....

  3. Fish stocking density impacts tank hydrodynamics

    DEFF Research Database (Denmark)

    Rasmussen, Michael R.; Lunger, Angela; Laursen, Jesper;

    2006-01-01

    hydrodynamics was established using in-tank-based Rhodamine WT fluorometry at a flow rate of 0.23 l s-1 (tank exchange rate of 1.9 h-1). With increasing numbers of animals, curvilinear relationships were observed for dispersion coefficients and tank mixing times. Stocking densities of 3, 6, 9 and 12 kg m-3......The effect of stocking density upon the hydrodynamics of a circular tank, configured in a recirculation system, was investigated. Red drums Sciaenops ocellatus of approximately 140 g wet weight, were stocked at five rates varying from 0 to 12 kg m-3. The impact of the presence of fish upon tank...

  4. Effect of fire engulfment on thermal response of LPG tanks.

    Science.gov (United States)

    Bi, Ming-shu; Ren, Jing-jie; Zhao, Bo; Che, Wei

    2011-08-30

    A model has been developed to predict the thermal response of liquefied-pressure gases (LPG) tanks under fire, and three-dimensional numerical simulations were carried out on a horizontal LPG tank which was 60% filled. Comparison between numerical predictions and published experimental data shows close agreement. The attention is focused on the influence of different fire conditions (different fire scenarios, various engulfing degrees and flame temperatures) on thermal response of LPG tanks. Potential hazard probabilities under different fire conditions were discussed by analyzing the maximum wall temperature and media energy after the internal pressure rose to the same value. It is found that the less severe fire scenario and lower engulfing case may lead to a greater probability of burst hazard because of the higher maximum wall temperature and media energy before the pressure relief valve (PRV) opens.

  5. OVERVIEW OF HANFORD SINGLE SHELL TANK (SST) STRUCTURAL INTEGRITY - 12123

    Energy Technology Data Exchange (ETDEWEB)

    RAST RS; RINKER MW; WASHENFELDER DJ; JOHNSON JB

    2012-01-25

    To improve the understanding of the single-shell tanks (SSTs) integrity, Washington River Protection Solutions, LLC (WRPS), the USDOE Hanford Site tank contractor, developed an enhanced Single-Shell Tank Integrity Project in 2009. An expert panel on SST integrity, consisting of various subject matters experts in industry and academia, was created to provide recommendations supporting the development of the project. This panel developed 33 recommendations in four main areas of interest: structural integrity, liner degradation, leak integrity and prevention, and mitigation of contamination migration. Seventeen of these recommendations were used to develop the basis for the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order, which is also known as the Tri-Party Agreement. The structural integrity of the tanks is a key element in completing the cleanup mission at the Hanford Site. There are eight primary recommendations related to the structural integrity of Hanford SSTs. Six recommendations are being implemented through current and planned activities. The structural integrity of the Hanford SSTs is being evaluated through analysis, monitoring, inspection, materials testing, and construction document review. Structural evaluation in the form of analysis is performed using modern finite element models generated in ANSYS{reg_sign} The analyses consider in-situ, thermal, operating loads and natural phenomena such as earthquakes. Structural analysis of 108 of 149 Hanford SSTs has concluded that the tanks are structurally sound and meet current industry standards. Analyses of the remaining Hanford SSTs are scheduled for FY2013. Hanford SSTs are monitored through a dome deflection program. The program looks for deflections of the tank dome greater than 1/4 inch. No such deflections have been recorded. The tanks are also subjected to visual inspection. Digital cameras record the interior surface of the concrete tank domes, looking for cracks and

  6. Research and Evaluation on Prediction Model of the Corrosion of Steel Oil Tank Bottom%钢质油罐罐底腐蚀预测模型研究与评价

    Institute of Scientific and Technical Information of China (English)

    王继纬; 但琦; 肖育; 邵武

    2013-01-01

      钢质油罐在储存油料时不可避免地会受到严重腐蚀。为能够掌握罐底的腐蚀程度,提出了一种由灰色系统理论和BP人工神经网络相结合的方法建立预测模型,对钢质油罐罐底腐蚀情况进行了预测,并通过实例计算给出了评价。计算结果表明,预测值与实测值相差很小,尤其对油料腐蚀这种涉及较多因素的复杂过程,该方法具有明显的优越性;该模型克服了传统预测模型需建立函数的难题,且预测精度较高,具有较高理论与实际应用价值。%Crude oil can be greatly corrosive to its storage equipment. In order to know the condition of the corrosion of tank bottom, this paper presents a new method which combines the theory of grey system and back⁃propagation(BP)artificial neural net⁃work to establish a prediction model. This model is used to predict the corrosion of oil tank bottom. Then, this paper gives estimation to the model by example simulation. Calculation results show that there exists non⁃obvious difference between prediction and testing values;there is distinctly advantage of the proposed method to the complex process of crude oil corrosion which is involved to many factors. The prediction model proposed in this paper can overcome the problem of establishing function relationship in traditional one and be of high accuracy in prediction;therefore, it is of great theoretical and practical value.

  7. Hanford Site Waste Storage Tank Information Notebook

    Energy Technology Data Exchange (ETDEWEB)

    Husa, E.I.; Raymond, R.E.; Welty, R.K.; Griffith, S.M.; Hanlon, B.M.; Rios, R.R.; Vermeulen, N.J.

    1993-07-01

    This report provides summary data on the radioactive waste stored in underground tanks in the 200 East and West Areas at the Hanford Site. The summary data covers each of the existing 161 Series 100 underground waste storage tanks (500,000 gallons and larger). It also contains information on the design and construction of these tanks. The information in this report is derived from existing reports that document the status of the tanks and their materials. This report also contains interior, surface photographs of each of the 54 Watch List tanks, which are those tanks identified as Priority I Hanford Site Tank Farm Safety Issues in accordance with Public Law 101-510, Section 3137*.

  8. Dynamic Response of Ground Supported Rectangular Water Tanks ...

    African Journals Online (AJOL)

    Bheema

    spring-mass model in the time history analysis for El-Centro earthquake ... components in any major water distribution network for public utility and industrial facilities. ... Some of the structural design codes that tackle fluid tank systems are the ...

  9. Temperature stratification in a hot water tank with circulation pipe

    DEFF Research Database (Denmark)

    Andersen, Elsa

    1998-01-01

    The aim of the project is to investigate the change in temperature stratification due to the operation of a circulation pipe. Further, putting forward rules for design of pipe inlet in order not to disturb the temperature stratification in the hot water tank. A validated computer model based...

  10. Successfully Mapping the U-Tank to an Electric Circuit

    Science.gov (United States)

    Hong, Seok-In

    2010-01-01

    Water-flow analogies are helpful in understanding electricity. For example, in the Lodge model, the constant DC voltage source (a battery) is represented by a U-tank with two water columns of the same cross-sectional area connected by a horizontal duct in which a pump is installed. The pump maintains the difference of the levels of the two water…

  11. Numerical Investigation of Microgravity Tank Pressure Rise Due to Boiling

    Science.gov (United States)

    Hylton, Sonya; Ibrahim, Mounir; Kartuzova, Olga; Kassemi, Mohammad

    2015-01-01

    The ability to control self-pressurization in cryogenic storage tanks is essential for NASAs long-term space exploration missions. Predictions of the tank pressure rise in Space are needed in order to inform the microgravity design and optimization process. Due to the fact that natural convection is very weak in microgravity, heat leaks into the tank can create superheated regions in the liquid. The superheated regions can instigate microgravity boiling, giving rise to pressure spikes during self-pressurization. In this work, a CFD model is developed to predict the magnitude and duration of the microgravity pressure spikes. The model uses the Schrage equation to calculate the mass transfer, with a different accommodation coefficient for evaporation at the interface, condensation at the interface, and boiling in the bulk liquid. The implicit VOF model was used to account for the moving interface, with bounded second order time discretization. Validation of the models predictions was carried out using microgravity data from the Tank Pressure Control Experiment, which flew aboard the Space Shuttle Mission STS-52. Although this experiment was meant to study pressurization and pressure control, it underwent boiling during several tests. The pressure rise predicted by the CFD model compared well with the experimental data. The ZBOT microgravity experiment is scheduled to fly on February 2016 aboard the ISS. The CFD model was also used to perform simulations for setting parametric limits for the Zero-Boil-Off Tank (ZBOT) Experiments Test Matrix in an attempt to avoid boiling in the majority of the test runs that are aimed to study pressure increase rates during self-pressurization. *Supported in part by NASA ISS Physical Sciences Research Program, NASA HQ, USA

  12. Non-Equilibrium Modeling and Simulation of Double Tank with Four Zones for CMT Water Supply System%CMT补水系统的双罐体四区非平衡建模与仿真

    Institute of Scientific and Technical Information of China (English)

    张亦宁; 吉宇; 李法社; 张昊春; 王亚辉

    2016-01-01

    AP1000核电系统属于第3代核电堆型,在我国核电发展中有望成为主力堆型。该堆型采用了非能动式堆芯冷却系统,全压补水箱(CMT)是其主要设备之一。针对全压补水箱补水系统的数学建模与数值模拟,能够对其可靠性进行验证,亦能够对正常及事故工况下全压堆芯补水系统的瞬态响应特性作出预测与评价。基于简化的全压堆芯补水箱补水系统,建立了双罐体4区非平衡模型,并运用Simulink动态仿真的方法进行数值模拟,得到了系统内压力、液位等主要参数随时间的变化情况。仿真结果与文献中类似模型的试验、仿真结果参数变化规律一致,能够为CMT补水系统瞬态分析提供理论依据。%AP1000 nuclear power system belongs to the third generation nuclear power reactor in China’s nucle-ar power development,which is expected to become the main type.The reactor core cooling system is a passive system,and the Core Makeup Tank(CMT)is one of the main types of equipment.Based on mathematical mod-eling and numerical simulation of the full pressure CMT,the reliability of CMT can be verified,and the transient response of the system under normal and accident conditions can also be predicted and evaluated.For a simpli-fied full pressure CMT system,a model consisting of 2 tanks and 4 regions is established,and by using Simulink dynamic simulation method,main parameters of the system,such as the inner pressure and liquid level are simu-lated.The simulation results are consistent with the similar model experiment and simulation results,which pro-vides a theoretical basis for the transient analysis of CMT system.

  13. Evaluation of 241 AN tank farm flammable gas behavior

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, D.A.

    1994-01-01

    The 241 AN Tank Farm tanks 241-AN-103, -104, and 105 are Flammable Gas Watch List tanks. Characteristics exhibited by these tanks (i.e., surface level drops, pressure increases, and temperature profiles) are similar to those exhibited by tank 241-SY-101, which is also a Watch List tank. Although the characteristics exhibited by tank 241-SY-101 are also present in tanks 241-AN-103, -104, and 105, they are exhibited to a lesser degree in the AN Tank Farm tanks. The 241 AN Tank Farm tanks have only small surface level drops, and the pressure changes that occur are not sufficient to release an amount of gas that would cause the dome space to exceed the lower flammability limit (LFL) for hydrogen. Therefore, additional restrictions are probably unnecessary for working within the 241 AN Tank Farm, either within the dome space of the tanks or in the waste.

  14. CRITICAL ASSUMPTIONS IN THE F-TANK FARM CLOSURE OPERATIONAL DOCUMENTATION REGARDING WASTE TANK INTERNAL CONFIGURATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Hommel, S.; Fountain, D.

    2012-03-28

    The intent of this document is to provide clarification of critical assumptions regarding the internal configurations of liquid waste tanks at operational closure, with respect to F-Tank Farm (FTF) closure documentation. For the purposes of this document, FTF closure documentation includes: (1) Performance Assessment for the F-Tank Farm at the Savannah River Site (hereafter referred to as the FTF PA) (SRS-REG-2007-00002), (2) Basis for Section 3116 Determination for Closure of F-Tank Farm at the Savannah River Site (DOE/SRS-WD-2012-001), (3) Tier 1 Closure Plan for the F-Area Waste Tank Systems at the Savannah River Site (SRR-CWDA-2010-00147), (4) F-Tank Farm Tanks 18 and 19 DOE Manual 435.1-1 Tier 2 Closure Plan Savannah River Site (SRR-CWDA-2011-00015), (5) Industrial Wastewater Closure Module for the Liquid Waste Tanks 18 and 19 (SRRCWDA-2010-00003), and (6) Tank 18/Tank 19 Special Analysis for the Performance Assessment for the F-Tank Farm at the Savannah River Site (hereafter referred to as the Tank 18/Tank 19 Special Analysis) (SRR-CWDA-2010-00124). Note that the first three FTF closure documents listed apply to the entire FTF, whereas the last three FTF closure documents listed are specific to Tanks 18 and 19. These two waste tanks are expected to be the first two tanks to be grouted and operationally closed under the current suite of FTF closure documents and many of the assumptions and approaches that apply to these two tanks are also applicable to the other FTF waste tanks and operational closure processes.

  15. Energy storage-boiler tank

    Science.gov (United States)

    Chubb, T. A.; Nemecek, J. J.; Simmons, D. E.

    1980-01-01

    Activities performed in an effort to demonstrate heat of fusion energy storage in containerized salts are reported. The properties and cycle life characteristics of a eutectic salt having a boiling point of about 385 C (NaCl, KCl, Mg Cl2) were determined. M-terphenyl was chosen as the heat transfer fluid. Compatibility studies were conducted and mild steel containers were selected. The design and fabrication of a 2MWh storage boiler tank are discussed.

  16. Development of a 3D CFD model for velocity and concentration field of a jet flow in CANDU-6 moderator tank induced by high velocity injection of liquid neutron poison

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Bo Wook; Choi, Hang Bok [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Yun, Hye Jeong [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    2005-05-15

    This report describes the development and validation work of developing a 3D CFD model for analyzing the liquid poison jet velocity and concentration which is necessary for the performance test of SDS2 of CANDU-6 among the forseeable problems expected in the CANDU-6 loaded with DUPIC fuel. As a boundary condition the liquid poison injection rate through each injection hole was given and the 3D CFD model for analyzing the downstream flow and concentration field is developed and validated. The injection rate is calculated by the ALITRIG code developed by AECL. As the ratio of the calandria tank and the injection hole drilled at the injection nozzle is as big as 2000, the grid generation for the calandria is very difficult as the number of the grid can easily exceed the computational load limit of the available work station. Thus to overcome this difficulty the inlet jet flow has been modeled as a source term of the mass, momentum and concentration at the grid near the real inlet. This modeling method enabled the analysis of the jet velocity and concentration possible within the computation limit of the available work station. And as the experimental data available for validating this model has only video taped pictures, and the jet height growth rate is estimated by the observer's subjective judgement, it was most difficult to convert the location of the jet front to the corresponding concentration value. Utilizing the experiment data from Bhabha Atomic Research Center in India, the jet growth rate was validated and the result was very much encouraging. Based on the results the 3D CFD model developed in this report shows physically reasonable results and will be used for the analysis of SDS2 performance test along with the reactor physics codes.

  17. Mixing Processes in High-Level Waste Tanks - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, P.F.

    1999-05-24

    The mixing processes in large, complex enclosures using one-dimensional differential equations, with transport in free and wall jets is modeled using standard integral techniques. With this goal in mind, we have constructed a simple, computationally efficient numerical tool, the Berkeley Mechanistic Mixing Model, which can be used to predict the transient evolution of fuel and oxygen concentrations in DOE high-level waste tanks following loss of ventilation, and validate the model against a series of experiments.

  18. HANFORD DOUBLE SHELL TANK (DST) THERMAL & SEISMIC PROJECT BUCKLING EVALUATION METHODS & RESULTS FOR THE PRIMARY TANKS

    Energy Technology Data Exchange (ETDEWEB)

    MACKEY, T.C.

    2006-03-17

    This report documents a detailed buckling evaluation of the primary tanks in the Hanford double shell waste tanks. The analysis is part of a comprehensive structural review for the Double-Shell Tank Integrity Project. This work also provides information on tank integrity that specifically responds to concerns raise by the Office of Environment, Safety, and Health (ES&H) Oversight (EH-22) during a review (in April and May 2001) of work being performed on the double-shell tank farms, and the operation of the aging waste facility (AWF) primary tank ventilation system.

  19. 241-SY Tank Farm Construction Extent of Condition Review for Tank Integrity

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, Travis J.; Boomer, Kayle D.; Gunter, Jason R.; Venetz, Theodore J.

    2013-07-25

    This report provides the results of an extent of condition construction history review for tanks 241-SY-101, 241-SY-102, and 241-SY-103. The construction history of the 241-SY tank farm has been reviewed to identify issues similar to those experienced during tank 241-AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank 241-AY-102 as the comparison benchmark. In the 241-SY tank farm, the third DST farm constructed, refractory quality and stress relief were improved, while similar tank and liner fabrication issues remained.

  20. 241-AZ Tank Farm Construction Extent of Condition Review for Tank Integrity

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, Travis J.; Boomer, Kayle D.; Gunter, Jason R.; Venetz, Theodore J.

    2013-07-30

    This report provides the results of an extent of condition construction history review for tanks 241-AZ-101 and 241-AZ-102. The construction history of the 241-AZ tank farm has been reviewed to identify issues similar to those experienced during tank AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank AY-102 as the comparison benchmark. In the 241-AZ tank farm, the second DST farm constructed, both refractory quality and tank and liner fabrication were improved.