WorldWideScience

Sample records for non-radiative heat flows

  1. Heat Pipe Blocks Return Flow

    Science.gov (United States)

    Eninger, J. E.

    1982-01-01

    Metal-foil reed valve in conventional slab-wick heat pipe limits heat flow to one direction only. With sink warmer than source, reed is forced closed and fluid returns to source side through annular transfer wick. When this occurs, wick slab on sink side of valve dries out and heat pipe ceases to conduct heat.

  2. Magnetic heat pump flow director

    Science.gov (United States)

    Howard, Frank S. (Inventor)

    1995-01-01

    A fluid flow director is disclosed. The director comprises a handle body and combed-teeth extending from one side of the body. The body can be formed of a clear plastic such as acrylic. The director can be used with heat exchangers such as a magnetic heat pump and can minimize the undesired mixing of fluid flows. The types of heat exchangers can encompass both heat pumps and refrigerators. The director can adjust the fluid flow of liquid or gas along desired flow directions. A method of applying the flow director within a magnetic heat pump application is also disclosed where the comb-teeth portions of the director are inserted into the fluid flow paths of the heat pump.

  3. Magnetic Heat Pump Containing Flow Diverters

    Science.gov (United States)

    Howard, Frank S.

    1995-01-01

    Proposed magnetic heat pump contains flow diverters for suppression of undesired flows. If left unchecked, undesired flows mix substantial amounts of partially heated and partially cooled portions of working fluid, effectively causing leakage of heat from heated side to cooled side. By reducing leakage of heat, flow diverters increase energy efficiency of magnetic heat pump, potentially offering efficiency greater than compressor-driven refrigerator.

  4. Magnetic Heat Pump Containing Flow Diverters

    Science.gov (United States)

    Howard, Frank S.

    1995-01-01

    Proposed magnetic heat pump contains flow diverters for suppression of undesired flows. If left unchecked, undesired flows mix substantial amounts of partially heated and partially cooled portions of working fluid, effectively causing leakage of heat from heated side to cooled side. By reducing leakage of heat, flow diverters increase energy efficiency of magnetic heat pump, potentially offering efficiency greater than compressor-driven refrigerator.

  5. Joule heating in electrokinetic flow.

    Science.gov (United States)

    Xuan, Xiangchun

    2008-01-01

    Electrokinetic flow is an efficient means to manipulate liquids and samples in lab-on-a-chip devices. It has a number of significant advantages over conventional pressure-driven flow. However, there exists inevitable Joule heating in electrokinetic flow, which is known to cause temperature variations in liquids and draw disturbances to electric, flow and concentration fields via temperature-dependent material properties. Therefore, both the throughput and the resolution of analytic studies performed in microfluidic devices are affected. This article reviews the recent progress on the topic of Joule heating and its effect in electrokinetic flow, particularly the theoretical and experimental accomplishments from the aspects of fluid mechanics and heat/mass transfer. The primary focus is placed on the temperature-induced flow variations and the accompanying phenomena at the whole channel or chip level.

  6. Heat flow in the Arctic

    Science.gov (United States)

    Lachenbruch, Arthur H.; Marshall, B. Vaughan

    1969-01-01

    Defines heat flow as the flux at the earth's solid surface of heat conducted from the interior; the heat-flow-unit (hfu) is on the order of 1-millionth calorie through each sq cm of the surface/sec, which is enough to melt a 4-mm layer of ice over the earth's surface/yr. Earth heat originates from radioactive decay of U, Th and K in the crust and mantle. Although land heat-flow measurements in the Arctic are too few for regional interpretation, those from Cape Thompson, Barrow and Cape Simpson, Northern Alaska are discussed and figured to show what they contribute to understanding of permafrost, climatic change and shoreline movements. Measuring thermal conductivity and gradient is much simpler in ocean basins than on land. Locations of such measurements are mapped, the results for the Alaskan quadrant in more detail. The sharp change in heat flow at the edge of the Alpha Cordillera, shown in a geothermal model, suggests that this feature is a huge accumulation of basalt, rather than mantle material or remnant of a foundering continent as previously postulated. Future Arctic heat flow studies are discussed.

  7. Role of radiogenic heat generation in surface heat flow formation

    Science.gov (United States)

    Khutorskoi, M. D.; Polyak, B. G.

    2016-03-01

    Heat generation due to decay of long-lived radioactive isotopes is considered in the Earth's crust of the Archean-Proterozoic and Paleozoic provinces of Eurasia and North America. The heat flow that forms in the mantle is calculated as the difference between the heat flow observed at the boundary of the solid Earth and radiogenic heat flow produced in the crust. The heat regime in regions with anomalously high radiogenic heat generation is discussed. The relationship between various heat flow components in the Precambrian and Phanerozoic provinces has been comparatively analyzed, and the role of erosion of the surfaceheat- generating layer has been estimated.

  8. Applied research in hydraulics and heat flow

    CERN Document Server

    Asli, Kaveh Hariri; Asli, Hossein Hariri; Motlaghzadeh, Kasra

    2014-01-01

    PrefaceModeling for Heat Flow ProcessFluid and Fluid MechanicsTwo Phases Flow and Vapor BubbleDynamic Modeling for Heat and Mass TransferVapor Pressure and Saturation TemperatureFinite Difference and Method of Characteristics for Transitional FlowLagrangian and Eulerian Transitional FlowDynamic Modeling for Water FlowModeling for Flow ProcessDynamic Modeling for Mass and Momentum TransportIndex

  9. Axial flow heat exchanger devices and methods for heat transfer using axial flow devices

    Energy Technology Data Exchange (ETDEWEB)

    Koplow, Jeffrey P.

    2016-02-16

    Systems and methods described herein are directed to rotary heat exchangers configured to transfer heat to a heat transfer medium flowing in substantially axial direction within the heat exchangers. Exemplary heat exchangers include a heat conducting structure which is configured to be in thermal contact with a thermal load or a thermal sink, and a heat transfer structure rotatably coupled to the heat conducting structure to form a gap region between the heat conducting structure and the heat transfer structure, the heat transfer structure being configured to rotate during operation of the device. In example devices heat may be transferred across the gap region from a heated axial flow of the heat transfer medium to a cool stationary heat conducting structure, or from a heated stationary conducting structure to a cool axial flow of the heat transfer medium.

  10. Crustal Heat Production and Mantle Heat Flow in Southeast China

    Institute of Scientific and Technical Information of China (English)

    胡圣标; 汪集旸

    1994-01-01

    The correlation between seismic velocity (vp) and radiogenic heat production (A) en-ables the distribution of crustal heat production to be evaluated,from which the mantle heat flow for 21seismic velocity-depth profiles located along the two continental geotraverses in Southeast China can bededuced.Several approaches have been proposed to special problems connected with the conversion ofseismic velocities into heat production in orogenic areas.The results show that the crustal heat flow inSoutheast China is quite inhomogeneous,varying between 17.8 and 46 mW·m-2,which can be attribut-ed to the complicated crustal structure related to overthrusting and overlapping in the upper crust.The re-markable regional variation in the mantle heat flow,ranging from 23.2 to 41.6 mW·m-2,correspondsto the large-scale tectonothermal evolution of the orogenic belts.

  11. Heat flow in northwest Pacific marginal seas

    Institute of Scientific and Technical Information of China (English)

    JIANG Lili; LI Guanbao; LI Naisheng

    2004-01-01

    Heat flow studies in Northwest Pacific marginal seas has a more than 40 years history with more than 4000 heat flow values obtained. The regional average value is 80.4 mW/m2, which is lower than the world's 87 mW/m2, but higher than those of the Eurasia continent and the Pacific Ocean. This reflects the regional crust property in the area. The studies on distribution of the heat flow and contour pattern of heat flow in 1°×1°and 2°×2°scales in Northwest Pacific marginal seas revealed that the most high heat flow anomalies in the area were found along back-arc basins and island arc in an obviously northeasterly track. Exceptions are the Komandoskaya Basin (KMB), the Izu-Bonin Trough (IBT) and the Mariana Trough (MT), which extend in northwest. The contours of low heat flow marked the boundaries of the continent and the ocean. The present heat flow values reflect the imprint of the last thermal event and relate closely to tectonic activity. The high heat flow gradient areas have high frequency of earthquake. Therefore, the area of faulting controlled the pattern of the heat flow anomalies. Heat flow gradient in 135°direction indicated a major lithosphere transformation oceanward resulting from movement of the earth's material. In this paper, we described patterns of heat flow distribution in the Northwest Pacific, heat flow value changes in horizontal and vertical directions, combining the studies of Shi (1997) on the landforms of the island arcs in east Asia and plate movement, and the results of Shi and Zhang (1998) on heat simulation of subduction of active ocean mountain and the activity of islands arc. A preliminary model of geodynamics in the Northwest Pacific and its adjacent area was put forward. There is a great lateral heat flow gradient on the surface of the mantle between ocean and continent, which indicates that the materials in asthenosphere move from continent to ocean causing movement of the crust.

  12. Pneumatic Proboscis Heat-Flow Probe

    Science.gov (United States)

    Zacny, Kris; Hedlund, Magnus; Mumm, Eric; Shasho, Jeffrey; Chu, Philip; Kumar, Nishant

    2013-01-01

    Heat flow is a fundamental property of a planet, and provides significant constraints on the abundance of radiogenic isotopes, the thermal evolution and differentiation history, and the mechanical properties of the lithosphere. Heat-flow measurements are also essential in achieving at least four of the goals set out by the National Research Council for future lunar exploration. The heat-flow probe therefore directly addresses the goal of the Lunar Geophysical Network, which is to understand the interior structure and composition of the Moon. A key challenge for heat flow measurement is to install thermal sensors to the depths approximately equal to 3 m that are not influenced by the diurnal, annual, and longer-term fluctuations of the surface thermal environment. In addition, once deployed, the heat flow probe should cause little disturbance to the thermal regime of the surrounding regolith. A heat-flow probe system was developed that has two novel features: (1) it utilizes a pneumatic (gas) approach, excavates a hole by lofting the lunar soil out of the hole, and (2) deploys the heat flow probe, which utilizes a coiled up tape as a thermal probe to reach greater than 3-meter depth. The system is a game-changer for small lunar landers as it exhibits extremely low mass, volume, and simple deployment. The pneumatic system takes advantage of the helium gas used for pressurizing liquid propellant of the lander. Normally, helium is vented once the lander is on the surface, but it can be utilized for powering pneumatic systems. Should sufficient helium not be available, a simple gas delivery system may be taken specifically for the heat flow probe. Either way, the pneumatic heat flow probe system would be much lighter than other systems that entirely rely on the electrical power of the lander.

  13. Thermodynamics of Flow Boiling Heat Transfer

    Science.gov (United States)

    Collado, F. J.

    2003-05-01

    Convective boiling in sub-cooled water flowing through a heated channel is essential in many engineering applications where high heat flux needs to be accommodated. It has been customary to represent the heat transfer by the boiling curve, which shows the heat flux versus the wall-minus-saturation temperature difference. However it is a rather complicated problem, and recent revisions of two-phase flow and heat transfer note that calculated values of boiling heat transfer coefficients present many uncertainties. Quite recently, the author has shown that the average thermal gap in the heated channel (the wall temperature minus the average temperature of the coolant) was tightly connected with the thermodynamic efficiency of a theoretical reversible engine placed in this thermal gap. In this work, whereas this correlation is checked again with data taken by General Electric (task III) for water at high pressure, a possible connection between this wall efficiency and the reversible-work theorem is explored.

  14. Pneumatic Proboscis Heat Flow Probe Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The heat flow probe directly answers requirements in the topic: S1.11 Lunar Science Instruments and Technology: "Geophysical Measurements: Systems, subsystems, and...

  15. Characteristics of heat flow in recuperative heat exchangers

    Directory of Open Access Journals (Sweden)

    Lalović Milisav

    2005-01-01

    Full Text Available A simplified model of heat flow in cross-flow tube recuperative heat exchangers (recuperators was presented in this paper. One of the purposes of this investigation was to analyze changes in the values of some parameters of heat transfer in recuperators during combustion air preheating. The logarithmic mean temperature (Atm and overall heat transfer coefficient (U, are two basic parameters of heat flow, while the total heated area surface (A is assumed to be constant. The results, presented as graphs and in the form of mathematical expressions, were obtained by analytical methods and using experimental data. The conditions of gaseous fuel combustions were defined by the heat value of gaseous fuel Qd = 9263.894 J.m-3, excess air ratio λ= 1.10, content of oxygen in combustion air ν(O2 = 26%Vol, the preheating temperature of combustion air (cold fluid outlet temperature tco = 100-500°C, the inlet temperature of combustion products (hot fluid inlet temperature thi = 600-1100°C.

  16. Stirling Engine With Radial Flow Heat Exchangers

    Science.gov (United States)

    Vitale, N.; Yarr, George

    1993-01-01

    Conflict between thermodynamical and structural requirements resolved. In Stirling engine of new cylindrical configuration, regenerator and acceptor and rejector heat exchangers channel flow of working gas in radial direction. Isotherms in regenerator ideally concentric cylinders, and gradient of temperature across regenerator radial rather than axial. Acceptor and rejector heat exchangers located radially inward and outward of regenerator, respectively. Enables substantial increase in power of engine without corresponding increase in diameter of pressure vessel.

  17. Heat transfer mechanisms in microgravity flow boiling.

    Science.gov (United States)

    Ohta, Haruhiko

    2002-10-01

    The objective of this paper is to clarify the mechanisms of heat transfer and dryout phenomena in flow boiling under microgravity conditions. Liquid-vapor behavior in annular flow, encountered in the moderate quality region, has extreme significance for practical application in space. To clarify the gravity effect on the heat transfer observed for an upward flow in a tube, the research described here started from the measurement of pressure drop for binary gas-liquid mixture under various gravity conditions. The shear stress acting on the surface of the annular liquid film was correlated by an empirical method. Gravity effects on the heat transfer due to two-phase forced convection were investigated by the analysis of velocity and temperature profiles in the film. The results reproduce well the trends of heat transfer coefficients varying with the gravity level, quality, and mass velocity. Dryout phenomena in the moderate quality region were observed in detail by the introduction of a transparent heated tube. At heat fluxes just lower and higher than CHF value, a transition of the heat transfer coefficient was calculated from oscillating wall temperature, where a series of opposing heat transfer trends--the enhancement due to the quenching of dried areas or evaporation from thin liquid films and the deterioration due to the extension of dry patches--were observed between the passage of disturbance waves. The CHF condition that resulted from the insufficient decrease of wall temperature in the period of enhanced heat transfer was overcome by a temperature increase in the deterioration period. No clear effect of gravity on the mechanisms of dryout was observed within the range of experiments.

  18. Free convection film flows and heat transfer

    CERN Document Server

    Shang, Deyi

    2010-01-01

    Presents development of systematic studies for hydrodynamics and heat and mass transfer in laminar free convection, accelerating film boiling and condensation of Newtonian fluids, and accelerating film flow of non-Newtonian power-law fluids. This book provides a system of analysis models with a developed velocity component method.

  19. Nonequilibrium invariant measure under heat flow.

    Science.gov (United States)

    Delfini, Luca; Lepri, Stefano; Livi, Roberto; Politi, Antonio

    2008-09-19

    We provide an explicit representation of the nonequilibrium invariant measure for a chain of harmonic oscillators with conservative noise in the presence of stationary heat flow. By first determining the covariance matrix, we are able to express the measure as the product of Gaussian distributions aligned along some collective modes that are spatially localized with power-law tails. Numerical studies show that such a representation applies also to a purely deterministic model, the quartic Fermi-Pasta-Ulam chain.

  20. Heat flow diagnostics for helicon plasmasa)

    Science.gov (United States)

    Berisford, Daniel F.; Bengtson, Roger D.; Raja, Laxminarayan L.; Cassady, Leonard D.; Chancery, William J.

    2008-10-01

    We present experimental studies of power balance in an argon helicon discharge. An infrared camera measures the heating of the dielectric tube containing a helicon discharge based on measurement of temperature profiles of the tube surface before and after a rf pulse. Using this diagnostic, we have measured surface heating trends at a variety of operating conditions on two helicon systems: the 10kW VASIMR VX-50 experiment and the University of Texas at Austin 1kW helicon experiment. Power losses downstream from the antenna are measured using thermocouples and probes. The heating of the dielectric tube increases with decreasing magnetic fields, higher gas flow rates, and higher molecular mass of the gas. These preliminary results suggest that cross-field particle diffusion contributes a significant proportion of the energy flux to the wall.

  1. Visualization of working fluid flow in gravity assisted heat pipe

    Directory of Open Access Journals (Sweden)

    Nemec Patrik

    2015-01-01

    Full Text Available Heat pipe is device working with phase changes of working fluid inside hermetically closed pipe at specific pressure. The phase changes of working fluid from fluid to vapor and vice versa help heat pipe to transport high heat flux. The article deal about construction and processes casing in heat pipe during operation. Experiment visualization of working fluid flow is performed with glass heat pipe filed with ethanol. The visualization of working fluid flow explains the phenomena as working fluid boiling, nucleation of bubbles, vapor flow, vapor condensation on the wall, vapor and condensate flow interaction, flow down condensate film thickness on the wall, occurred during the heat pipe operation.

  2. Visualization of working fluid flow in gravity assisted heat pipe

    Science.gov (United States)

    Nemec, Patrik; Malcho, Milan

    2015-05-01

    Heat pipe is device working with phase changes of working fluid inside hermetically closed pipe at specific pressure. The phase changes of working fluid from fluid to vapor and vice versa help heat pipe to transport high heat flux. The article deal about construction and processes casing in heat pipe during operation. Experiment visualization of working fluid flow is performed with glass heat pipe filed with ethanol. The visualization of working fluid flow explains the phenomena as working fluid boiling, nucleation of bubbles, vapor flow, vapor condensation on the wall, vapor and condensate flow interaction, flow down condensate film thickness on the wall, occurred during the heat pipe operation.

  3. Flow characteristics and heat transfer in wavy walled channels

    Science.gov (United States)

    Mills, Zachary; Shah, Tapan; Monts, Vontravis; Warey, Alok; Balestrino, Sandro; Alexeev, Alexander

    2013-11-01

    Using lattice Boltzmann simulations, we investigated the effects of wavy channel geometry on the flow and heat transfer within a parallel plate heat exchanger. We observed three distinct flow regimes that include steady flow with and without recirculation and unsteady time-periodic flow. We determined the critical Reynolds numbers at which the flow transitions between different flow regimes. To validate our computational results, we compared the simulated flow structures with the structures observed in a flowing soap film. Furthermore, we examine the effects of the wavy channel geometry on the heat transfer. We find that the unsteady flow regime drastically enhances the rate of heat transfer and show that heat exchangers with wavy walls outperform currently used heat exchangers with similar volume and power characteristics. Results from our study point to a simple and efficient method for increasing performance in compact heat exchangers.

  4. Laboratory Investigations of Lava Flow Heat Transfer

    Science.gov (United States)

    Fagents, S. A.; Rumpf, M. E.; Hamilton, C. W.

    2011-12-01

    To investigate the effectiveness with which lava can heat substrates of different types, we conducted a suite of experiments in which molten basalt was poured onto solid or particulate materials, and the downward propagation of the heat pulse was measured. The motivation for this work lies in seeking to understand how lava flows on the Moon would have heated the underlying regolith, and thus to determine the depths at which solar wind particles implanted in the regolith would have been protected from the heat of the overlying flow. Extraction and analysis of ancient solar wind samples would provide a wealth of information on the evolution and fate of the Sun. Our experimental device consists of a box constructed from 1"-thick calcium silicate sheeting with interior dimensions of 20 x 20 x 25 cm. The substrate material (a particulate lunar regolith simulant or solid basalt) occupies the lower 15 cm of the box, which is embedded with an array of 8 thermocouples. Up to 6 kg of crushed basalt collected from the 2010 Kilauea lava flows is heated to supraliquidus temperatures and poured directly onto the substrate. The evolution of the temperature profile within the lava flow and substrate is recorded as the basalt cools, and the surface temperature distribution is recorded using a Forward Looking Infrared Radiometer (FLIR) video camera. We have been using the experimental data sets to validate a numerical model of substrate heating. If the physics is appropriately formulated, the model will accurately predict both surface and internal temperature distribution as a function of time. A key issue has been incorporation of valid temperature-dependent thermophysical properties, because particulate materials are not well characterized at elevated temperatures. Regolith thermal conductivity in particular exerts a strong control over the depth of penetration of the thermal wave, so its accurate description is essential for a robust model. Comparison of experimental vs. modeled

  5. Heat transfer and fluid flow in microchannels

    Science.gov (United States)

    Mala, Ghulam Mohiuddin

    Fluid flow and heat transfer characteristics in microchannels of different cross-sections; parallel plate, cylindrical and trapezoidal microchannels were studied. The trapezoidal microchannels were etched in silicon and glass by photolithographic techniques. The cylindrical microchannels of fused silica and stainless steel were readily available. Channels with depths of 18 μm to 300 μm were studied. The study was divided into three parts viz. theoretical modeling, numerical simulation and experimentation. Electrokinetic effects such as the effects of electrical double layer (EDL) at the solid-liquid interface and surface roughness effects were considered. An experimental apparatus was constructed and a procedure devised to measure the flow rate, pressure drop, temperatures and electrokinetic parameters like streaming potential, streaming current, and conductivity of the working fluid. Great care was taken so that the measurements were accurate and repeatable. For steady state laminar flow and heat transfer in microchannels, mathematical models were developed that consider the effects of electrical double layer and surface roughness at the microchannel walls. The non- linear, 2-D, Poisson-Boltzmann equation that describes the potential distribution at the solid liquid interface was solved numerically and results were compared with a linear approximate solution that overestimates the potential distribution for higher values of zeta potential. Effects of the EDL field at the solid-liquid interface, surface roughness at the microchannel walls and the channel size, on the velocity distribution, streaming potential, apparent viscosity, temperature distribution and heat transfer characteristics are discussed. The experimental results indicate significant departure in flow characteristics from the predictions of the Navier-Stokes equations, referred to as conventional theory. The difference between the experimental results and theoretical predictions decreases as the

  6. Flow mechanism and heat transfer enhancement in longitudinal-flow tube bundle of shell-and-tube heat exchanger

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The flow disturbance and heat transfer mechanism in the tube bundle of rod baffle shell-and-tube heat exchanger were analyzed, on the basis of which and combined with the concept of heat transfer enhancement in the core flow, a new type of shell-and-tube heat exchanger with combination of rod and van type spoiler was designed. Corresponding mathematical and physical models on the shell side about the new type heat exchanger were established, and fluid flow and heat transfer characteristics were numerically analyzed. The simulation results showed that heat transfer coefficient of the new type of heat exchanger approximated to that of rod baffle heat exchanger, but flow pressure drop was much less than the latter, indicating that comprehensive performance of the former is superior to that of the latter. Compared with rod baffle heat exchanger, heat transfer coefficient of the heat exchanger under investigation is higher under same pressure drop, especially under the high Reynolds numbers.

  7. Underworld and multi-basin heat flow

    Science.gov (United States)

    Quenette, S. M.; O'Neill, C.; Moresi, L. N.; Danis, C. R.; Mansour, J.

    2011-12-01

    We present an over arching method for non-linear heat flow assessments of large, multi-basin systems. Our example is the Sydney-, Gunnedah-, Bowen basins (Danis et al 2011), which covers an area of 800kms by 1900kms and depth of 5kms, on the east coast of Australia. It is used as a baseline towards further fluid and structural geodynamics oriented analysis. In contrast to reservoir scale geothermal models - basin, multi-basin and towards lithosphere scale models exhibit their own challenges in terms of physical/rheological behaviour and computational tractability. For instance we model a non-linear heat flow by means of temperature dependent conductivity, as indicated by Clauser and Huenges (1995), which allows crystalline basement rocks, such as granites, to show for example a significant decrease in conductivity from ambient temperature up to around 400C, dropping from around 3 mK**(units) to around 2. For this modelling, a specialisation of the geodynamics code 'Underworld' (Moresi et al 2007) called Underworld-GT is used. A toolbox is added to the otherwise un-touched Underworld code adding geothermal workflow and context to Underworld. A particular novel feature is the ability to load stratigraphic layers, and/or GoCAD or GeoModeller voxel sets as the constraining geological geometry, whilst allowing the heat assessment models to scale from 1 process to 1000s. Another is the ability to prescribe synthetic drill holes, and its use in stochastic-oriented assessments of model parameters. Following the Underworld platform's approach and its simple PDE abstraction layer, these model configurations from a baseline for further additions to the governing equations such as fluid flow and structure, enabling a bridge between reservoir and continental scale dynamics, albeit with their own computational challenges.

  8. On Inverting the Heat Flow with Engineering Materials

    Science.gov (United States)

    Zhou, Li

    2016-02-01

    Transformation thermodynamics enriches our understanding of heat flow and makes it possible to manipulate the heat flow at will, like shielding, concentrating and inverting. The inverting of heat flow is the extreme one, which has not been studied specifically yet. In this study we firstly inverted the heat flow by transformation thermodynamics and provided the formula for the transformed thermal conductivity. Finite element simulations were conducted to realize the steady and non-steady inverting of heat flow, based on the eccentric-semi-ring structures with natural materials. To do the inverting of heat flow, a simple "L"-shape conductive structure was proposed and verified with an infrared camera. It is concluded that inverting heat flow can be done by both complex engineering materials and some simple structures.

  9. Visualization of working fluid flow in gravity assisted heat pipe

    OpenAIRE

    Nemec Patrik; Malcho Milan

    2015-01-01

    Heat pipe is device working with phase changes of working fluid inside hermetically closed pipe at specific pressure. The phase changes of working fluid from fluid to vapor and vice versa help heat pipe to transport high heat flux. The article deal about construction and processes casing in heat pipe during operation. Experiment visualization of working fluid flow is performed with glass heat pipe filed with ethanol. The visualization of working fluid flow explains the phenomena as working fl...

  10. The present-day heat flow structure of Mars

    Science.gov (United States)

    Parro, L. M.; Jiménez-Díaz, A.; Mansilla, F.; Ruiz, J.

    2016-12-01

    Until the arrival of in-situ measurements, the study of the current heat flow of Mars goes through indirect methods, mainly based on the relation between the thermal state of lithosphere and their mechanical strength, or on theoretical models of internal evolution. Here, we present a first-order global model for the present-day surface heat flow for Mars, based on the current radiogenic heat production of the crust and mantle, scaling heat flow variations arising from crustal thickness and topography crustal thickness variations, and on the heat flow derived from the effective elastic thickness of the lithosphere beneath the North Polar Region. Our preferred model find heat flows varying between 14 and 23 mW m-2, with an average value of 18.6 mW m-2. Similar results are obtained if we use heat flow based on the lithosphere strength of the South Polar Region. Moreover, expressing our results in terms of the Urey ratio (the ratio between total internal heat production and heat loss), we have values close to 0.8, which indicates a moderate contribution of secular cooling to the heat flow of Mars (consistent with low heat flow values deduced from lithosphere strength), unless that heat-producing elements abundances for Mars are subchondritics.

  11. Present-day heat flow model of Mars

    Science.gov (United States)

    Parro, Laura M.; Jiménez-Díaz, Alberto; Mansilla, Federico; Ruiz, Javier

    2017-04-01

    Until the acquisition of in-situ measurements, the study of the present-day heat flow of Mars must rely on indirect methods, mainly based on the relation between the thermal state of the lithosphere and its mechanical strength, or on theoretical models of internal evolution. Here, we present a first-order global model for the present-day surface heat flow for Mars, based on the radiogenic heat production of the crust and mantle, on scaling of heat flow variations arising from crustal thickness and topography variations, and on the heat flow derived from the effective elastic thickness of the lithosphere beneath the North Polar Region. Our preferred model finds heat flows varying between 14 and 25 mW m-2, with an average value of 19 mW m-2. Similar results (although about ten percent higher) are obtained if we use heat flow based on the lithospheric strength of the South Polar Region. Moreover, expressing our results in terms of the Urey ratio (the ratio between total internal heat production and total heat loss through the surface), we estimate values close to 0.7-0.75, which indicates a moderate contribution of secular cooling to the heat flow of Mars (consistent with the low heat flow values deduced from lithosphere strength), unless heat-producing elements abundances for Mars are subchondritic.

  12. Present-day heat flow model of Mars.

    Science.gov (United States)

    Parro, Laura M; Jiménez-Díaz, Alberto; Mansilla, Federico; Ruiz, Javier

    2017-04-03

    Until the acquisition of in-situ measurements, the study of the present-day heat flow of Mars must rely on indirect methods, mainly based on the relation between the thermal state of the lithosphere and its mechanical strength, or on theoretical models of internal evolution. Here, we present a first-order global model for the present-day surface heat flow for Mars, based on the radiogenic heat production of the crust and mantle, on scaling of heat flow variations arising from crustal thickness and topography variations, and on the heat flow derived from the effective elastic thickness of the lithosphere beneath the North Polar Region. Our preferred model finds heat flows varying between 14 and 25 mW m(-2), with an average value of 19 mW m(-2). Similar results (although about ten percent higher) are obtained if we use heat flow based on the lithospheric strength of the South Polar Region. Moreover, expressing our results in terms of the Urey ratio (the ratio between total internal heat production and total heat loss through the surface), we estimate values close to 0.7-0.75, which indicates a moderate contribution of secular cooling to the heat flow of Mars (consistent with the low heat flow values deduced from lithosphere strength), unless heat-producing elements abundances for Mars are subchondritic.

  13. Heat flow distribution in Chinese continent and its adjacent areas

    Institute of Scientific and Technical Information of China (English)

    Wei Tao; Zhengkang Shen

    2008-01-01

    Using a compilation of 6980 heat flow measurements, we produce a new heat flow map for the Chinese continent and its adjacent areas. We develop an objective and integrated method to interpolate the heat flow data, taking into account both the uniformity within geological units and coherency of regional heat flow. The geologic units are outlined based on Zhang et al.'s active tectonic block model.Our heat flow model is presented in two formats: a contour map and a heat flow dataset with values on a 1 × 1° grid for the Chinese continent and its adjacent areas, reflecting detailed variations in some regions. Also provided is a resolution map which helps understand the reliability of the heat flow model. Our results reveal that (1) Heat flows in the eastern part of the Chinese continent are relatively higher than those in the western part except that in the Tibetan Plateau area. (2) Heat flows in the Ordos and North China blocks are around 60 mW/m2, and are 50-55 mW/m2 in South China except for the continental marginal sea regions. (3) Heat flow is the lowest in the Jtmggar Basin, only 35-45 mW/m2, and is 45-55 mW/m2 in the Tarim Basin. The results of this study provide an important data-set for studies on thermal and rheological structures of the Chinese continent and its adjacent areas.

  14. Heat transfer and fluid flow in minichannels and microchannels

    CERN Document Server

    Kandlikar, Satish; Li, Dongqing; Colin, Stephane; King, Michael R

    2013-01-01

    Heat exchangers with minichannel and microchannel flow passages are becoming increasingly popular due to their ability to remove large heat fluxes under single-phase and two-phase applications. Heat Transfer and Fluid Flow in Minichannels and Microchannels methodically covers gas, liquid, and electrokinetic flows, as well as flow boiling and condensation, in minichannel and microchannel applications. Examining biomedical applications as well, the book is an ideal reference for anyone involved in the design processes of microchannel flow passages in a heat exchanger. Each chapter is accompan

  15. Convective heat transfer measurement involving flow past stationary circular disks

    Energy Technology Data Exchange (ETDEWEB)

    Wedekind, G.L. (Oakland Univ., Rochester, MI (United States))

    1989-11-01

    Considerable empirical data exist in the literature for forced convection heat transfer involving external flow over a variety of geometries, and for various ranges of Reynolds number. This author is not aware of any published empirical data for forced convection heat transfer involving flow past a simple stationary circular disk, whose axis is perpendicular to the flow. Such is the purpose of this paper.

  16. Inverted annular flow heat transfer in a natural circulation loop

    Energy Technology Data Exchange (ETDEWEB)

    Ozawa, M.; Umekawa, H.; Shiba, Y.; Yano, T. [Kansai Univ., Osaka (Japan)

    1998-07-01

    Gravity-feed reflooding experiment was conducted in a natural circulation loop of liquid nitrogen. The cooling curve of high temperature tube wall had a characteristic feature, i.e. initial rapid cooling with steam binding, relatively long-time plateau, gradual decrease with or without flow oscillation, and final drastic decrease during quenching process. Such phenomena had close relationship to the heated wall dynamics and heating power transient. To provide fundamental understanding on the present phenomena, the heat transfer data in inverted annular and dispersed flows were obtained under steady or oscillatory flow condition. The experimental data suggested that the heat transfer coefficient in the inverted annular or dispersed flow regimes is a slightly increasing function of heat flux but significantly depended on the tube diameter. The flow oscillation deteriorated heat transfer slightly in the inverted annular and dispersed flow regimes but significantly in the quenching process.

  17. Simulation Studies on A Cross Flow Plate Fin Heat Exchanger

    Directory of Open Access Journals (Sweden)

    M. Thirumarimurugan

    2008-01-01

    Full Text Available Compact heat exchangers which were initially developed for the aerospace industries in the1940s have been considerably improved in the past few years. The main reasons for the goodperformance of compact heat exchangers are their special design which includes turbulent which inturn use high heat transfer coefficient and resists fouling, and maximum temperature driving forcebetween the hot and cold fluids. Numerous types use special enhancement techniques to achieve therequired heat transfer in smaller plot areas and, in many cases, less initial investment. One such type ofcompact heat exchanger is the Plate-fin heat exchanger. The complexity of compact heat exchangerdesign equations results from the exchangers unique ability to transfer heat between multiple processstreams and a wide array of possible flow configurations. This paper presents the performanceevaluation of cross flow plate fin heat exchanger with several different Gas-Liquid systems.Experimental results such as exchanger effectiveness, overall heat transfer coefficients were calculatedfor the flow systems of Cross flow Heat Exchangers. A steady state model for the outlet temperature ofboth the cold and hot fluid and overall heat transfer coefficient of a plate-fin cross flow heat exchangerwas developed and simulated using MATLAB, which was verified with the experiments conducted.

  18. An analytical model for annular flow boiling heat transfer in microchannel heat sinks

    Energy Technology Data Exchange (ETDEWEB)

    Megahed, A.; Hassan, I. [Concordia University, Montreal, QC (Canada). Dept. of Mechanical and Industrial Engineering

    2009-07-01

    An analytical model has been developed to predict flow boiling heat transfer coefficient in microchannel heat sinks. The new analytical model is proposed to predict the two-phase heat transfer coefficient during annular flow regime based on the separated model. Opposing to the majority of annular flow heat transfer models, the model is based on fundamental conservation principles. The model considers the characteristics of microchannel heat sink during annular flow and eliminates using any empirical closure relations. Comparison with limited experimental data was found to validate the usefulness of this analytical model. The model predicts the experimental data with a mean absolute error 8%. (author)

  19. A New Determination of Io's Heat Flow Using Diurnal Heat Balance Constraints

    Science.gov (United States)

    Spencer, J. R.; Rathbun, J. A.; McEwen, A. S.; Pearl, J. C.; Bastos, A.; Andrade, J.; Correia, M.; Barros, S.

    2002-01-01

    We use heat balance arguments to obtain a new estimate of Io's heat flow that does not depend on assumptions about the temperatures of its thermal anomalies. Our estimated heat flow is somewhat less than 2.2 +/- 0.9 W/sq m. Additional information is contained in the original extended abstract.

  20. Working fluid flow visualization in gravity heat pipe

    Directory of Open Access Journals (Sweden)

    Nemec Patrik

    2016-01-01

    Full Text Available Heat pipe is device working with phase changes of working fluid inside hermetically closed pipe at specific pressure. The phase changes of working fluid from fluid to vapour and vice versa help heat pipe to transport high heat flux. The article deal about gravity heat pipe construction and processes casing inside during heat pipe operation. Experiment working fluid flow visualization is performed with two glass heat pipes with different inner diameter (13 mm and 22 mm and filled with water. The working fluid flow visualization explains the phenomena as a working fluid boiling, nucleation of bubbles, and vapour condensation on the wall, vapour and condensate flow interaction, flow down condensate film thickness on the wall occurred during the heat pipe operation.

  1. Working fluid flow visualization in gravity heat pipe

    Science.gov (United States)

    Nemec, Patrik; Malcho, Milan

    2016-03-01

    Heat pipe is device working with phase changes of working fluid inside hermetically closed pipe at specific pressure. The phase changes of working fluid from fluid to vapour and vice versa help heat pipe to transport high heat flux. The article deal about gravity heat pipe construction and processes casing inside during heat pipe operation. Experiment working fluid flow visualization is performed with two glass heat pipes with different inner diameter (13 mm and 22 mm) and filled with water. The working fluid flow visualization explains the phenomena as a working fluid boiling, nucleation of bubbles, and vapour condensation on the wall, vapour and condensate flow interaction, flow down condensate film thickness on the wall occurred during the heat pipe operation.

  2. Heat flow and thermal maturity in the Williston Basin

    Energy Technology Data Exchange (ETDEWEB)

    Gosnold, W.; LeFever, R. [North Dakota Univ., Grand Forks, ND (United States)

    2009-07-01

    This presentation discussed steady-state heat sources, transient disturbances, and the chemical kinetics and hydrocarbon potential of the Williston Basin. Global average heat flow has been estimated at 87 mW per m{sup 2}, while total surface heat flux is 44.2 x TW. Heat flow within ocean basins correlates with age, while heat flow on continents is related to radioactive heat production in the continental crust. The mantle flux of the continental crust averages 27 mW per m{sup 2}. Heat flow correlates with tectonic age. Transient signals in continental heat flow include groundwater flow, ground cover changes, and climatic changes. However, subsurface temperatures can be calculated when heat flow and thermal conductivity are known, using Fourier's law of heat conduction. Thermal maturity is a measure of the degree of kerogen metamorphism in a formation, and can provide an estimate of the maximum temperature that a formation has reached when combined with an understanding of chemical kinetics and thermal history. The kinetic reaction rate depends on the absolute temperature as well as the amount of reactants. The reaction rate is a function of absolute temperature, frequency factor, and activation energy. The hydrocarbon potential can then be estimated for different kerogen types across a range of activation energies. tabs., figs.

  3. Boiling heat transfer of refrigerant R-21 in upward flow in plate-fin heat exchanger

    Science.gov (United States)

    Kuznetsov, V. V.; Shamirzaev, A. S.

    2015-11-01

    The article presents the results of experimental investigation of boiling heat transfer of refrigerant R-21 in upward flow in a vertical plate-fin heat exchanger with transverse size of the channels that is smaller than the capillary constant. The heat transfer coefficients obtained in ranges of small mass velocities and low heat fluxes, which are typical of the industry, have been poorly studied yet. The characteristic patterns of the upward liquid-vapor flow in the heat exchanger channels and the regions of their existence are detected. The obtained data show a weak dependence of heat transfer coefficient on equilibrium vapor quality, mass flow rate, and heat flux density and do not correspond to calculations by the known heat transfer models. A possible reason for this behavior is a decisive influence of evaporation of thin liquid films on the heat transfer at low heat flux.

  4. Planetary heat flow from shallow subsurface measurements: Mars

    Science.gov (United States)

    Cornwall, Marc; Hagermann, Axel

    2016-10-01

    Planetary heat flow probes measure heat flow (depth-resolved temperature and thermal conductivity) to provide insight into the internal state of a planet. The probes have been utilized extensively on Earth, twice on the Moon, and once on the Surface of comet 67P-CG. Mars is an important target for heat flow measurement as heat flow is a critical parameter in Martian thermal history models. Earlier studies indicate that Martian planetary heat flow can be accessed at 5 m below the surface in dry regolith monitored over at least one Martian year. A one Martian year monitoring period is necessary because, in the shallow subsurface, heat flow from the interior is superposed with time varying heat flow contributions, primarily due to insolation. Given that a heat flow probe may not achieve its target depth or monitoring period, this study investigates how the depth (2-5 m), duration (0-1 Martian year) and quality of measurements influence the accuracy of planetary heat flow. An inverse model is used to show that, in the preceding scenarios, the accuracy of planetary heat flow directly estimated from depth-dependent thermal conductivity with 10-20% precision errors, temperatures with 50-100 mK precision errors and modelling uncertainties up to 500 mK, can, on average, be improved by a factor of 27 with optimization to 13%. Accuracies increase with sensor penetration depth and regolith monitoring period. Heat flow optimized from instantaneous measurements or those with the shortest regolith monitoring periods have increased accuracy where the frequency and amplitude of the temperature variation are lowest. The inverse model is based on the Function Specification Inversion method. This study demonstrates that a solution subspace can be identified within a space of uncertainties modelled for the temperature measurements and planetary heat flow: the subspace is defined by a constant log-ratio of their respective standard deviations. Optimized heat flow estimates display

  5. Non-radiative excitation fluorescence microscopy

    Science.gov (United States)

    Riachy, Lina; Vézy, Cyrille; Jaffiol, Rodolphe

    2016-03-01

    Non-radiative Excitation Fluorescence Microscopy (NEFM) constitutes a new way to observe biological samples beyond the diffraction limit. Non-radiative excitation of the samples is achieved by coating the substrate with donor species, such as quantum dots (QDs). Thus the dyes are not excited directly by the laser source, as in common fluorescence microscopy, but through a non-radiative energy transfer. To prevent dewetting of the donor film, we have recently implemented a silanization process to covalently bond the QDs on the substrate. An homogeneous monolayer of QDs was then deposited on only one side of the coverslips. Atomic force microscopy was then used to characterize the QD layer. We highlight the potential of our method through the study of Giant Unilamellar Vesicles (GUVs) labeled with DiD as acceptor, in interaction with surface functionalized with poly-L-lysine. In the presence of GUVs, we observed a quenching of QDs emission, together with an emission of DiD located in the membrane, which clearly indicated that non-radiative energy transfer from QDs to DiD occurs.

  6. Heat transfer in flow past a continuously moving porous flat plate with heat flux

    Digital Repository Service at National Institute of Oceanography (India)

    Murty, T.V.R.; Sarma, Y.V.B.

    The analysis of the heat transfer in flow past a continuously moving semi-infinite plate in the presence of suction/ injection with heat flux has been presented. Similarity solutions have been derived and the resulting equations are integrated...

  7. Critical heat flux in flow boiling in microchannels

    CERN Document Server

    Saha, Sujoy Kumar

    2015-01-01

    This Brief concerns the important problem of critical heat flux in flow boiling in microchannels. A companion edition in the SpringerBrief Subseries on Thermal Engineering and Applied Science to “Heat Transfer and Pressure Drop in Flow Boiling in Microchannels,” by the same author team, this volume is idea for professionals, researchers, and graduate students concerned with electronic cooling.

  8. Temperatures and Heat Flows in a Soil Enclosing a Slinky Horizontal Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Pavel Neuberger

    2014-02-01

    Full Text Available Temperature changes and heat flows in soils that host “slinky”-type horizontal heat exchangers are complex, but need to be understood if robust quantification of the thermal energy available to a ground-source heat pump is to be achieved. Of particular interest is the capacity of the thermal energy content of the soil to regenerate when the heat exchangers are not operating. Analysis of specific heat flows and the specific thermal energy regime within the soil, including that captured by the heat-exchangers, has been characterised by meticulous measurements. These reveal that high concentrations of antifreeze mix in the heat-transfer fluid of the heat exchanger have an adverse impact on heat flows discharged into the soil.

  9. Analysis of the flow structure and heat transfer in a vertical mantle heat exchanger

    DEFF Research Database (Denmark)

    Knudsen, Søren; Morrison, GL; Behnia, M

    2005-01-01

    initially mixed and initially stratified inner tank and mantle. The analysis of the heat transfer showed that the flow in the mantle near the inlet is mixed convection flow and that the heat transfer is dependent on the mantle inlet temperature relative to the core tank temperature at the mantle level. (C......The flow structure inside the inner tank and inside the mantle of a vertical mantle heat exchanger was investigated using a full-scale tank designed to facilitate flow visualisation. The flow structure and velocities in the inner tank and in the mantle were measured using a Particle Image...... Velocimetry (PIV) system. A Computational Fluid Dynamics (CFD) model of the vertical mantle heat exchanger was also developed for a detailed evaluation of the heat flux at the mantle wall and at the tank wall. The flow structure was evaluated for both high and low temperature incoming flows and for both...

  10. Inductive heating with magnetic materials inside flow reactors.

    Science.gov (United States)

    Ceylan, Sascha; Coutable, Ludovic; Wegner, Jens; Kirschning, Andreas

    2011-02-07

    Superparamagnetic nanoparticles coated with silica gel or alternatively steel beads are new fixed-bed materials for flow reactors that efficiently heat reaction mixtures in an inductive field under flow conditions. The scope and limitations of these novel heating materials are investigated in comparison with conventional and microwave heating. The results suggest that inductive heating can be compared to microwave heating with respect to rate acceleration. It is also demonstrated that a very large diversity of different reactions can be performed under flow conditions by using inductively heated flow reactors. These include transfer hydrogenations, heterocyclic condensations, pericyclic reactions, organometallic reactions, multicomponent reactions, reductive cyclizations, homogeneous and heterogeneous transition-metal catalysis. Silica-coated iron oxide nanoparticles are stable under many chemical conditions and the silica shell could be utilized for further functionalization with Pd nanoparticles, rendering catalytically active heatable iron oxide particles. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Low-Flow Film Boiling Heat Transfer on Vertical Surfaces

    DEFF Research Database (Denmark)

    Munthe Andersen, J. G.; Dix, G. E.; Leonard, J. E.

    1976-01-01

    The phenomenon of film boiling heat transfer for high wall temperatures has been investigated. Based on the assumption of laminar flow for the film, the continuity, momentum, and energy equations for the vapor film are solved and a Bromley-type analytical expression for the heat transfer...... length, an average film boiling heat transfer coefficient is obtained....

  12. Heat transfer measurements of the 1983 kilauea lava flow.

    Science.gov (United States)

    Hardee, H C

    1983-10-07

    Convective heat flow measurements of a basaltic lava flow were made during the 1983 eruption of Kilauea volcano in Hawaii. Eight field measurements of induced natural convection were made, giving heat flux values that ranged from 1.78 to 8.09 kilowatts per square meter at lava temperatures of 1088 and 1128 degrees Celsius, respectively. These field measurements of convective heat flux at subliquidus temperatures agree with previous laboratory measurements in furnace-melted samples of molten lava, and are useful for predicting heat transfer in magma bodies and for estimating heat extraction rates for magma energy.

  13. Two-phase Flow Distribution in Heat Exchanger Manifolds

    OpenAIRE

    Vist, Sivert

    2004-01-01

    The current study has investigated two-phase refrigerant flow distribution in heat exchange manifolds. Experimental data have been acquired in a heat exchanger test rig specially made for measurement of mass flow rate and gas and liquid distribution in the manifolds of compact heat exchangers. Twelve different manifold designs were used in the experiments, and CO2 and HFC-134a were used as refrigerants.

  14. Heat transfer and pressure drop in flow boiling in microchannels

    CERN Document Server

    Saha, Sujoy Kumar

    2016-01-01

    This Brief addresses the phenomena of heat transfer and pressure drop in flow boiling in micro channels occurring in high heat flux electronic cooling. A companion edition in the Springer Brief Subseries on Thermal Engineering and Applied Science to “Critical Heat Flux in Flow Boiling in Micro channels,” by the same author team, this volume is idea for professionals, researchers and graduate students concerned with electronic cooling.

  15. Cryogenic Heat Exchanger with Turbulent Flows

    Science.gov (United States)

    Amrit, Jay; Douay, Christelle; Dubois, Francis; Defresne, Gerard

    2012-01-01

    An evaporator-type cryogenic heat exchanger is designed and built for introducing fluid-solid heat exchange phenomena to undergraduates in a practical and efficient way. The heat exchanger functions at liquid nitrogen temperature and enables cooling of N[subscript 2] and He gases from room temperatures. We present first the experimental results of…

  16. Cryogenic Heat Exchanger with Turbulent Flows

    Science.gov (United States)

    Amrit, Jay; Douay, Christelle; Dubois, Francis; Defresne, Gerard

    2012-01-01

    An evaporator-type cryogenic heat exchanger is designed and built for introducing fluid-solid heat exchange phenomena to undergraduates in a practical and efficient way. The heat exchanger functions at liquid nitrogen temperature and enables cooling of N[subscript 2] and He gases from room temperatures. We present first the experimental results of…

  17. Simulation of rarefied gas flow and heat transfer in microchannels

    Institute of Scientific and Technical Information of China (English)

    王娴; 王秋旺; 陶文铨; 郑平

    2002-01-01

    Analysis and simulation of rarefied nitrogen gas flow and heat transfer were performed with the Knusden number ranging from 0.05 to 1.0, using the direct simulation of Monte Carlo (DSMC) method. The influences of the Kn number and the aspect ratio on the gas temperature and wall heat flux in the microchannels were studied parametrically. The total and local heat fluxes of the microchannel walls varying with the channel inlet velocities were also investigated in detail. It was found that the Kn number and the aspect ratio greatly influence the heat transfer performance of microchannels, and both the channel inlet and outlet have higher heat fluxes while the heat flux in the middle part of channels is very low. It is also found that the inlet free stream flow velocity has small affect on the wall total heat flux while it changes the distribution of local heat flux.

  18. Thermal performance modeling of cross-flow heat exchangers

    CERN Document Server

    Cabezas-Gómez, Luben; Saíz-Jabardo, José Maria

    2014-01-01

    This monograph introduces a numerical computational methodology for thermal performance modeling of cross-flow heat exchangers, with applications in chemical, refrigeration and automobile industries. This methodology allows obtaining effectiveness-number of transfer units (e-NTU) data and has been used for simulating several standard and complex flow arrangements configurations of cross-flow heat exchangers. Simulated results have been validated through comparisons with results from available exact and approximate analytical solutions. Very accurate results have been obtained over wide ranges

  19. Heat source models in simulation of heat flow in friction stir welding

    DEFF Research Database (Denmark)

    Schmidt, Henrik Nikolaj Blich; Hattel, Jesper

    2004-01-01

    . The convective heat transfer due to the material flow affects the temperature fields. Models presented previously in the literature allow the heat to flow through the probe volume, and the majority neglects the influence of the contact condition as the sliding condition is assumed. In this work, a number......The objective of the present paper is to investigate the effect of including the tool probe and the material flow in the numerical modelling of heat flow in friction stir welding (FSW). The contact condition at the interface between the tool and workpiece controls the heat transfer mechanisms...... of cases is established. Each case represents a combination of a contact condition, i.e. sliding and sticking, and a stage of refinement regarding the heat source distribution. In the most detailed models, the heat flow is forced around the probe volume by prescribing a velocity field in shear layers...

  20. Heat Source Models in Simulation of Heat Flow in Friction Stir Welding

    DEFF Research Database (Denmark)

    Schmidt, Henrik Nikolaj Blich; Hattel, Jesper

    2004-01-01

    . The convective heat transfer due to the material flow affects the temperature fields. Models presented previously in literature allow the heat to flow through the probe volume, and the majority of them neglect the influence of the contact condition as the sliding condition is assumed. In the present work......The objective of the present paper is to investigate the effect of including the tool probe and the material flow in the numerical modelling of heat flow in Friction Stir Welding (FSW). The contact condition at the interface between the tool and workpiece controls the heat transfer mechanisms......, a number of cases are established. Each case represents a combination of a contact condition, i.e. sliding and sticking, and a stage of refinement regarding the heat source distribution. In the most detailed models the heat flow is forced around the probe volume by prescribing a velocity field in shear...

  1. Analysis of slip flow heat transfer between two unsymmetrically heated parallel plates with viscous dissipation

    Indian Academy of Sciences (India)

    HARI MOHAN KUSHWAHA; SANTOSH K SAHU

    2016-06-01

    This paper presents an analytical investigation to study the heat transfer and fluid flow characteristics in the slip flow region for hydrodynamically and thermally fully developed flow between parallel plates.Both upper and lower plates are subjected to asymmetric heat flux boundary conditions. The effect of first ordervelocity slip, temperature jump, asymmetric heat flux ratio and viscous dissipation on the heat transfer performance is analyzed. Closed form expressions are obtained for the temperature distribution and Nusselt number. Present predictions are verified for the cases that neglect the viscous heating and microscale effects. The effect of asymmetric heat flux ratio with and without viscous dissipation on Nusselt number for both macroscale and microscale is highlighted. The heat transfer characteristics are found to depend on various modeling parameters, namely, modified Brinkman number, Knudsen number and heat flux ratio

  2. Heat transfer and flow characteristics on a gas turbine shroud.

    Science.gov (United States)

    Obata, M; Kumada, M; Ijichi, N

    2001-05-01

    The work described in this paper is an experimental investigation of the heat transfer from the main flow to a turbine shroud surface, which may be applicable to ceramic gas turbines. Three kinds of turbine shrouds are considered with a flat surface, a taper surface and a spiral groove surface opposite to the blades in an axial flow turbine of actual turbo-charger. Heat transfer measurements were performed for the experimental conditions of a uniform heat flux or a uniform wall temperature. The effects of the inlet flow angle, rotational speed, and tip clearance on the heat transfer coefficient were clarified under on- and off-design flow conditions. The mean heat transfer coefficient was correlated to the blade Reynolds number and tip clearance, and compared with an experimental correlation and measurements of a flat surface. A comparison was also made for the measurement of static pressure distributions.

  3. Flow Patterns and Thermal Drag in Supersonic Duct Flow with Heating

    Institute of Scientific and Technical Information of China (English)

    Zeng-YuanGuo; Zhi-HongLiu

    1994-01-01

    The supersonic duct flow with fixed back pressure to stagnation pressure ratio Pb/P0 under heating is investigated analytically.A “Flow Pattern Diagram” Which consists of six pattern zones is developed.By this diagram the actual flow state in supersonic duct flow system can be determined conveniently when Pb/Po and heating intensity are knows.It is impossible for flow with heavy heating to become supersonic,even though the pressure ratio is much smaller than the critical pressure ratio,Based on the analogy between viscous effect and heating effect a thermal drag factor has een defined.which can predict the flow property variation due to heating and the relaive importance of viscous effect and heating effect.

  4. Flow and heat transfer in compact offset strip fin surfaces

    Institute of Scientific and Technical Information of China (English)

    Junqi DONG; Jiangping CHEN; Zhijiu CHEN

    2008-01-01

    Experimental studies of air-side heat transfer and pressure drop characteristics of offset strip fins and flat tube heat exchangers were performed. A series of tests were conducted for 9 heat exchangers with different fin space, fin height, fin strip length and flow length, at a constant tube-side water flow rate of 2.5 m3/h. The char-acteristics of the heat transfer and pressure drop of differ-ent fin space, fin height and fin length were analyzed and compared. The curves of the heat transfer coefficients vs. The pumping power per unit frontal area were then plot-ted. Moreover, the enhanced heat transfer mechanism of offset strip fins was analyzed using field synergy theory. The results showed that fin length and flow length have more obviously effect on the thermal hydraulic character-istics of offset strip fins.

  5. The role of Compton heating in cluster cooling flows

    CERN Document Server

    Ciotti, L; Pellegrini, S

    2003-01-01

    Recent observations by Chandra and XMM-Newton demonstrate that the central gas in "cooling flow" galaxy clusters has a mass cooling rate that decreases rapidly with decreasing temperature. This contrasts the predictions of a steady state cooling flow model. On the basis of these observational results, the gas can be in a steady state only if a steady temperature dependent heating mechanism is present; alternatively the gas could be in an unsteady state, i.e., heated intermittently. Intermittent heating can be produced by accretion on the supermassive black hole residing in the central cluster galaxy, via Compton heating. This mechanism can be effective provided that the radiation temperature of the emitted spectrum is higher than the gas temperature. Here we explore whether this heating mechanism can be at the origin of the enigmatic behavior of the hot gas in the central regions of ``cooling flow'' clusters. Although several characteristics of Compton heating appear attractive in this respect, we find that t...

  6. Heat flow and ground water flow in the Great Plains of the United States

    Science.gov (United States)

    Gosnold, William D.

    1985-12-01

    Regional groundwater flow in deep aquifers adds advective components to the surface heat flow over extensive areas within the Great Plains province. The regional groundwater flow is driven by topographically controlled piezometric surfaces for confined aquifers that recharge either at high elevations on the western edge of the province or from subcrop contacts. The aquifers discharge at lower elevations to the east. The assymetrical geometry for the Denver and Kennedy Basins is such that the surface areas of aquifer recharge are small compared to the areas of discharge. Consequently, positive advective heat flow occurs over most of the province. The advective component of heat flow in the Denver Basin is on the order of 15 mW m -2 along a zone about 50 km wide that parallels the structure contours of the Dakota aquifer on the eastern margin of the Basin. The advective component of heat flow in the Kennedy Basin is on the order of 20 mW m -2 and occurs over an extensive area that coincides with the discharge areas of the Madison (Mississippian) and Dakota (Cretaceous) aquifers. Groundwater flow in Paleozoic and Mesozoic aquifers in the Williston Basin causes thermal anomalies that are seen in geothermal gradient data and in oil well temperature data. The pervasive nature of advective heat flow components in the Great Plains tends to mask the heat flow structure of the crust, and only heat flow data from holes drilled into the crystalline basement can be used for tectonic heat flow studies.

  7. The Helical Oscillating Heat Pipe: Flow Pattern Behaviour Study

    Directory of Open Access Journals (Sweden)

    Y. Sriudom

    2015-01-01

    Full Text Available This research aims to study the effect of evaporator temperature, pitch distance, and working fluid on the internal flow pattern and the heat transfer characteristics of the helical oscillating heat pipe. A Pyrex tube with an inner diameter of 2.4 mm was used to study the flow pattern in the evaporator section. The pitch distance varied at 1, 1.5, and 2 cm. Water and R-123 were used as working fluid with a filling ratio of 80% by total volume. In the evaporator section, the water temperature varied at 60, 75, and 90°C to supply heat to the heat pipe. In the condenser section, air with a temperature of 25°C was used as heat sink. From the results, it was found that 4 internal flow patterns, bubble flow, slug flow, annular flow, and stratified wavy flow, were observed in the evaporator section for both working fluids. The heat transfer rate decreased when the pitch distance was increased from 1 to 2 cm. The maximum heat flux was 2,132.6 and 1,773.4 W/m2 for the working fluid of R-123 and water, respectively. Both occurred at a pitch distance of 1 cm and an evaporator temperature of 90°C.

  8. Mechanism and control of convective heat transfer-- Coordination of velocity and heat flow fields

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A second look has been given at the mechanism of convective heat transfer based on the analogy between convection and conduction with heat sources. The strength of convective heat transfer depends not only on the fluid velocity and fluid properties, but also on the coordination of fluid velocity and heat flow fields. Hence, based on the included angle of velocity and temperature gradient vectors, the presence of fluid motion may enhance or reduce heat transfer. With this concept, the known heat transfer phenomena may be understood in a deeper way. More important is that some novel approaches of heat transfer control can be developed.

  9. Multilevel Flow Modeling of Domestic Heating Systems

    DEFF Research Database (Denmark)

    Hu, Junjie; Lind, Morten; You, Shi

    2012-01-01

    of complementing this reasoning methodology. Domestic heating systems, as the main resource to meet the thermal requirements of end-users, have different implementations in Europe in order to achieve various degrees of controllability and heating efficiencies. As all the heating systems serve the same basic needs...... i.e. supplying and transferring thermal energy, it is off interest to use MFM to investigate similarities and differences between different implementations. In this paper, three typical domestic European heating systems, which differ from each other in the number of temperature sensors and auxiliary...

  10. Heat and mass transfer and hydrodynamics in swirling flows (review)

    Science.gov (United States)

    Leont'ev, A. I.; Kuzma-Kichta, Yu. A.; Popov, I. A.

    2017-02-01

    Research results of Russian and foreign scientists of heat and mass transfer in whirling flows, swirling effect, superficial vortex generators, thermodynamics and hydrodynamics at micro- and nanoscales, burning at swirl of the flow, and technologies and apparatuses with the use of whirling currents for industry and power generation were presented and discussed at the "Heat and Mass Transfer in Whirling Currents" 5th International Conference. The choice of rational forms of the equipment flow parts when using whirling and swirling flows to increase efficiency of the heat-power equipment and of flow regimes and burning on the basis of deep study of the flow and heat transfer local parameters was set as the main research prospect. In this regard, there is noticeable progress in research methods of whirling and swirling flows. The number of computational treatments of swirling flows' local parameters has been increased. Development and advancement of the up to date computing models and national productivity software are very important for this process. All experimental works are carried out with up to date research methods of the local thermoshydraulic parameters, which enable one to reveal physical mechanisms of processes: PIV and LIV visualization techniques, high-speed and infrared photography, high speed registration of parameters of high-speed processes, etc. There is a problem of improvement of researchers' professional skills in the field of fluid mechanics to set adequately mathematics and physics problems of aerohydrodynamics for whirling and swirling flows and numerical and pilot investigations. It has been pointed out that issues of improvement of the cooling system and thermal protection effectiveness of heat-power and heat-transfer equipment units are still actual. It can be solved successfully using whirling and swirling flows as simple low power consumption exposing on the flow method and heat transfer augmentation.

  11. Temperatures and Heat Flows in a Soil Enclosing a Slinky Horizontal Heat Exchanger

    OpenAIRE

    Pavel Neuberger; Radomír Adamovský; Michaela Šeďová

    2014-01-01

    Temperature changes and heat flows in soils that host “slinky”-type horizontal heat exchangers are complex, but need to be understood if robust quantification of the thermal energy available to a ground-source heat pump is to be achieved. Of particular interest is the capacity of the thermal energy content of the soil to regenerate when the heat exchangers are not operating. Analysis of specific heat flows and the specific thermal energy regime within the soil, including that captured by the ...

  12. An analytical theory of heated duct flows in supersonic combustors

    Directory of Open Access Journals (Sweden)

    Chenxi Wu

    2014-01-01

    Full Text Available One-dimensional analytical theory is developed for supersonic duct flow with variation of cross section, wall friction, heat addition, and relations between the inlet and outlet flow parameters are obtained. By introducing a selfsimilar parameter, effects of heat releasing, wall friction, and change in cross section area on the flow can be normalized and a self-similar solution of the flow equations can be found. Based on the result of self-similar solution, the sufficient and necessary condition for the occurrence of thermal choking is derived. A relation of the maximum heat addition leading to thermal choking of the duct flow is derived as functions of area ratio, wall friction, and mass addition, which is an extension of the classic Rayleigh flow theory, where the effects of wall friction and mass addition are not considered. The present work is expected to provide fundamentals for developing an integral analytical theory for ramjets and scramjets.

  13. Burnett simulations of gas flow and heat transfer in microchannels

    Institute of Scientific and Technical Information of China (English)

    Fubing BAO; Jianzhong LIN

    2009-01-01

    In micro- and nanoscale gas flows, the flow falls into the transition flow regime. There are not enough molecule collisions and the gas deviates from the equilibrium. The Navier-Stokes equations fail to describe the gas flow in this regime. The direct simulation Monte Carlo method converges slowly and requires lots of computational time. As a result, the high-order Burnett equations are used to study the gas flow and heat transfer characteristics in micro- and nanoscale gas flows in this paper. The Burnett equations are first reviewed, and the augmented Burnett equations with high-order slip bound-ary conditions are then used to model the gas flow and heat transfer in Couette and Poiseuille flows in the transition regime.

  14. three-step model of dispersed flow heat transfer (post chf vertical flow)

    African Journals Online (AJOL)

    user

    The resulting equation gives the total heat transferred to the flow in terms of the mass flux, flow quality, .... superheated vapour, helps of course to desuperheat ... differential evaporation around the drop. The ... Thus we must first obtain the total.

  15. Role of plate-driven mantle flow in distribution of the global heat flow

    Institute of Scientific and Technical Information of China (English)

    叶正仁; 安镇文

    1999-01-01

    Heat flow in the Earth, from its hot interior to its relatively cool exterior, is the primary energy flow responsible for the dynamic nature of our planet. The motion of the plates excites a forced convective motion in the mantle, and this plate-driven mantle flow will strongly modulate the temperature field in the mantle because of the relatively high Peeler number of the mantle dynamic system. Here the role of the plate-driven mantle flow in the observed global heat flow is examined. The result reveals that the main feature of the distribution of the observed heat flow at the surface of the Earth matches well with the prediction and nearly one half of the average heat flow can be attributed to the thermal effect of the plate-driven mantle flow.

  16. Conjugate Compressible Fluid Flow and Heat Transfer in Ducts

    Science.gov (United States)

    Cross, M. F.

    2011-01-01

    A computational approach to modeling transient, compressible fluid flow with heat transfer in long, narrow ducts is presented. The primary application of the model is for analyzing fluid flow and heat transfer in solid propellant rocket motor nozzle joints during motor start-up, but the approach is relevant to a wide range of analyses involving rapid pressurization and filling of ducts. Fluid flow is modeled through solution of the spatially one-dimensional, transient Euler equations. Source terms are included in the governing equations to account for the effects of wall friction and heat transfer. The equation solver is fully-implicit, thus providing greater flexibility than an explicit solver. This approach allows for resolution of pressure wave effects on the flow as well as for fast calculation of the steady-state solution when a quasi-steady approach is sufficient. Solution of the one-dimensional Euler equations with source terms significantly reduces computational run times compared to general purpose computational fluid dynamics packages solving the Navier-Stokes equations with resolved boundary layers. In addition, conjugate heat transfer is more readily implemented using the approach described in this paper than with most general purpose computational fluid dynamics packages. The compressible flow code has been integrated with a transient heat transfer solver to analyze heat transfer between the fluid and surrounding structure. Conjugate fluid flow and heat transfer solutions are presented. The author is unaware of any previous work available in the open literature which uses the same approach described in this paper.

  17. Terrestrial heat flow in Junggar Basin,Northwest China

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Based on temperature logs of 117 boreholes and thermal conductivity of 119 rock samples,the first group of 35 heat flow data in the Junggar Basin are presented.The thermal gradients vary between 11.6 and 26.5℃/km ,and the thermal conductivity changes from 0.17 to 3.6 W/mK.Heat flow ranges from 23.4 to 53.7 mW/m2 with a mean of (42.3± 7.7) mW/m2.The heat flow pattern shows that heat flow is higher in the uplifts and lower in the depressions.The factors affecting the heat flow and its distribution include basin type,basement structure,sediment thickness,radioactive heat generation,etc.The overall low present-day heat flow in the Junggar Basin reflected its tectonothermal evolution characterized by lithospheric thickening,thrust and fault at shallow crust as well as consequently quick subsidence during the Late Cenozoic.

  18. The surface heat flow of the Arabian Shield in Jordan

    Science.gov (United States)

    Förster, A.; Förster, H.-J.; Masarweh, R.; Masri, A.; Tarawneh, K.; Desert Group

    2007-04-01

    Surface heat flow in southern Jordan (western part of the Arabian Plate) was determined in a dense cluster of five, up to 900-m-deep boreholes that have encountered sedimentary rocks of Paleozoic (Ordovician and Silurian) age. These rocks are underlain by an igneous and metamorphic basement, which has been studied for its radiogenic heat production, along the eastern margin of the Dead Sea Transform (DST) fault system. The heat flow, calculated from continuous temperature logs and laboratory-measured thermal conductivity of drillcores and surface samples, averages to 60.3 ± 3.4 mW m -2 and contrasts the common view of the late Proterozoic-consolidated Arabian Shield constituting a low heat-flow province of ⩽45 mW m -2. Although only characterizing an area of about 300 km 2, this average is unlikely representing a positive local anomaly caused by voluminous HHP granites/rhyolites at shallow depths. Instead, a heat flow of 60 mW m -2 is considered a robust estimate of the Phanerozoic conductive surface heat flow not only for Jordan, but for the Arabian Shield in areas unaffected by younger reactivation. The large variation in conductive heat flow (36-88 mW m -2) previously observed in Jordan, southern Syria, and Saudi Arabia is irreconcilable with their broad similarity in lithosphere structure and composition and rather reflects a combination of factors including low-quality temperature data and insufficient knowledge on thermal rock properties.

  19. Heating Cooling Flows with Weak Shock Waves

    CERN Document Server

    Mathews, W G; Brighenti, F

    2006-01-01

    The discovery of extended, approximately spherical weak shock waves in the hot intercluster gas in Perseus and Virgo has precipitated the notion that these waves may be the primary heating process that explains why so little gas cools to low temperatures. This type of heating has received additional support from recent gasdynamical models. We show here that outward propagating, dissipating waves deposit most of their energy near the center of the cluster atmosphere. Consequently, if the gas is heated by (intermittent) weak shocks for several Gyrs, the gas within 30-50 kpc is heated to temperatures that far exceed observed values. This heating can be avoided if dissipating shocks are sufficiently infrequent or weak so as not to be the primary source of global heating. Local PV and viscous heating associated with newly formed X-ray cavities are likely to be small, which is consistent with the low gas temperatures generally observed near the centers of groups and clusters where the cavities are located.

  20. Fluid flow and heat transfer in rotating porous media

    CERN Document Server

    Vadasz, Peter

    2016-01-01

    This Book concentrates the available knowledge on rotating fluid flow and heat transfer in porous media in one single reference. Dr. Vadasz develops the fundamental theory of rotating flow and heat transfer in porous media and introduces systematic classification and identification of the relevant problems. An initial distinction between rotating flows in isothermal heterogeneous porous systems and natural convection in homogeneous non-­‐isothermal porous systems provides the two major classes of problems to be considered. A few examples of solutions to selected problems are presented, highlighting the significant impact of rotation on the flow in porous media.

  1. Laminar fluid flow and heat transfer in a fin-tube heat exchanger with vortex generators

    Energy Technology Data Exchange (ETDEWEB)

    Yanagihara, J.I.; Rodriques, R. Jr. [Polytechnic School of Univ. of Sao Paolo, Sao Paolo (Brazil). Dept. of Mechanical Engineering

    1996-12-31

    Development of heat transfer enhancement techniques for fin-tube heat exchangers has great importance in industry. In recent years, heat transfer augmentation by vortex generators has been considered for use in plate fin-tube heat exchangers. The present work describes a numerical investigation about the influence of delta winglet pairs of vortex generators on the flow structure and heat transfer of a plate fin-tube channel. The Navier-Stokes and Energy equations are solved by the finite volume method using a boundary-fitted coordinate system. The influence of vortex generators parameters such as position, angle of attack and aspect ratio were investigated. Local and global influences of vortex generators in heat transfer and flow losses were analyzed by comparison with a model using smooth fin. The results indicate great advantages of this type of geometry for application in plate fin-tube heat exchangers, in terms of large heat transfer enhancement and small pressure loss penalty. (author)

  2. Novel Heat Flow Probe Design and Deployment Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a novel method for deploying heat flow sensors/heaters in a hole and also a novel approach to subsurface access using a percussive method. The...

  3. Modeling Io's Heat Flow: Constraints from Galileo PPR Data

    Science.gov (United States)

    Rathbun, J. A.; Spencer, J. R.; Tamppari, L. K.

    2000-01-01

    We attempt to improve on previous Io heat flow estimates by using higher resolution data from Galileo Photopolarimeter Radiometer (PPR) and improved thermophysical models of the surface, including finite thermal inertia, the pedestal effect, and disk-resolved radiance.

  4. New determinations of geothermal heat flow in France

    Energy Technology Data Exchange (ETDEWEB)

    Bertaux, M.G. (Universite Pierre-et-Marie Curie, Paris); Bienfait, G.; Bottinga, Y.

    1978-03-28

    A brief analysis of geothermal heat flow determinations obtained in France during the past few years is presented. General trends were compared with older measurements and new data published in Europe.

  5. Heat flow measurements on the Lomonosov Ridge, Arctic Ocean

    Institute of Scientific and Technical Information of China (English)

    XIAO Wentao; ZHANG Tao; ZHENG Yulong; GAO Jinyao

    2013-01-01

    Heat flow was measured on the Lomonosov Ridge during the 5th Chinese National Arctic Expedition in 2012. To derive the time-temperature curve, resistivity data were transformed to temperature by the resistivity-temperature program. Direct reading and linear regression methods were used to calculate the equilibrium temperature, which were regressed against the depth of the probes in sediment to derive the geothermal gradient. Then, heat flow was calculated as the product of geothermal gradient and thermal conductivity of sediments. The heat flow values on the basis of the two methods were similar (i.e., 67.27 mW/m2 and 63.99 mW/m2, respectively). The results are consistent with the measurements carried out at adjacent sites. The age of the Lomonosov Ridge predicted by the heat flow-age model was 62 Ma, which is in accordance with the inference that the ridge was separated from Eurasia at about 60 Ma.

  6. Flow boiling heat transfer in circulating fluidized bed

    Institute of Scientific and Technical Information of China (English)

    Xiaoguang REN; Jiangdong ZHENG; Sefiane KHELLII; Arumemi-Ikhide MICHAEL

    2009-01-01

    In order to enhance heat transfer and mitigate contamination in the boiling processes, a new type of vapor-liquid-solid (3-phase) circulating fluidized bed boil-ing system has been designed, combining a circulating fluidized bed with boiling heat transfer. Experimental results show an enhancement of the boiling curve. Flow visualization studies concerning flow hydrodynamics within the riser column are also conducted whose results are presented and discussed.

  7. Creeping Viscous Flow around a Heat-Generating Solid Sphere

    DEFF Research Database (Denmark)

    Krenk, Steen

    1981-01-01

    The velocity field for creeping viscous flow around a solid sphere due to a spherically symmetric thermal field is determined and a simple thermal generalization of Stokes' formula is obtained. The velocity field due to an instantaneous heat source at the center of the sphere is obtained in close...... form and an application to the storage of heat-generating nuclear waste is discussed....

  8. New terrestrial heat flow measurements on the Nazca Plate

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, R.N. (Columbia Univ., Palisades, NY); Langseth, M.G.; Vacquier, V.; Francheteau, J.

    1976-03-01

    Sixty-seven new heat flow measurements on the Nazca Plate are reported, and the thermal regimes of three specific areas on the plate are examined. The Nazca Ridge is an aseismic ridge which may have been generated as an ''island trail'' from the Easter Island ''hot spot'' and/or may be a fossil transform fault. The Nazca Ridge has lower heat flow than the surrounding sea floor implying that the ridge might have low ''effective'' thermal conductivity causing heat to preferentially flow or refract to surrounding ocean crust which has higher conductivity, or, the low heat flow values may be caused by hydrothermal circulation on the ridge. The Carnegie Plateau is an elevated region south of the Carnegie Ridge on the northeastern Nazca Plate with high heat flow and shallow topography consistent with an age of less than 20 m.y. B.P. The central Nazca Plate is an area of highly variable heat flow which is possibly related to thin sediment and to rough regional topography.

  9. Laminar Flow and Heat Transfer Characteristics in Jackets of Triangular Flow Channels

    Institute of Scientific and Technical Information of China (English)

    王翠华; 刘胜举; 吴剑华; 李雅侠

    2013-01-01

    Laminar flow and heat transfer characteristics of jacketed vessel with triangular flow channels were numerically studied under hydrodynamically and thermally fully developed conditions. Constant heat flux at the heated wall was assumed. The numerical program code in terms of vorticity, stream function, axial velocity com-ponent and energy equations was written based on a finite volume method. Based on the numerical results, the flow and temperature field were given, and the effects of Dean and Prandtl numbers on flow and heat transfer were ex-amined, and the correlations of flow resistance and mean Nusselt number were developed for the jacket. The results show that the structure of secondary flow is steady two vortices in the investigated range of dimensionless curvature ratio and Reynolds number. Two peaks of local Nusselt number increase significantly with Prandtl and Dean num-ber increasing, but the local Nusselt numbers near two ends and at the center of the heated wall increase only slightly. The center and two ends of heated wall are the poor positions for heat transfer in the jacket. Compared with the outer half coil jacket at the same area of heated wall, curvature radius, Reynolds number and Prandtl number, the jacket of triangular flow channel has lower flow resistance and less mean Nusselt number.

  10. Heat flow and hydrocarbon generation in the Transylvanian basin, Romania

    Energy Technology Data Exchange (ETDEWEB)

    Cranganu, C.; Deming, D. [Univ. of Oklahoma, Norman (United States)

    1996-10-01

    The Transylvanian basin in central Romania is a Neogene depression superimposed on the Cretaceous nappe system of the Carpathian Mountains. The basin contains the main gas reserves of Romania, and is one of the most important gas-producing areas of continental Europe; since 1902, gas has been produced from more than 60 fields. Surface heat flow in the Transylvanian basin as estimated in other studies ranges from 26 to 58 mW/m{sup 2}, with a mean value of 38 mW/m{sup 2}, relatively low compared to surrounding areas. The effect of sedimentation on heat flow and temperature in the Transylvanian basin was estimated with a numerical model that solved the heat equation in one dimension. Because both sediment thickness and heat flow vary widely throughout the Transylvanian basin, a wide range of model variables were used to bracket the range of possibilities. Three different burial histories were considered (thin, average, and thick), along with three different values of background heat flow (low, average, and high). Altogether, nine different model permutations were studied. Modeling results show that average heat flow in the Transylvanian basin was depressed approximately 16% during rapid Miocene sedimentation, whereas present-day heat flow remains depressed, on average, about 17% below equilibrium values. We estimated source rock maturation and the timing of hydrocarbon generation by applying Lopatin`s method. Potential source rocks in the Transylvanian basin are Oligocene-Miocene, Cretaceous, and Jurassic black shales. Results show that potential source rocks entered the oil window no earlier than approximately 13 Ma, at depths of between 4200 and 8800 m. Most simulations encompassing a realistic range of sediment thicknesses and background heat flows show that potential source rocks presently are in the oil window; however, no oil has ever been discovered or produced in the Transylvanian basin.

  11. Entropy resistance analyses of a two-stream parallel flow heat exchanger with viscous heating

    Institute of Scientific and Technical Information of China (English)

    Cheng Xue-Tao; Liang Xin-Gang

    2013-01-01

    Heat exchangers are widely used in industry,and analyses and optimizations of the performance of heat exchangers are important topics.In this paper,we define the concept of entropy resistance based on the entropy generation analyses of a one-dimensional heat transfer process.With this concept,a two-stream parallel flow heat exchanger with viscous heating is analyzed and discussed.It is found that the minimization of entropy resistance always leads to the maximum heat transfer rate for the discussed two-stream parallel flow heat exchanger,while the minimizations of entropy generation rate,entropy generation numbers,and revised entropy generation number do not always.

  12. Experimental stand for investigation of fluid flow in heat exchangers with cross-flow arrangement

    Directory of Open Access Journals (Sweden)

    Łopata Stanisław

    2017-01-01

    Full Text Available The operation analysis of high-performance heat exchanger with tubes elliptical indicated that the heat exchangers can be subject to damage. The reason for this is probably improper distribution of working fluid in tubular space of heat exchanger. Therefore, a part of the tubes may be improperly cooled and subject to compressible stresses. The paper presents an experimental stand allowing to confirm the given assumption. The experimental investigation enables to examine the mass flow rate in heat exchanger tubes. Also, it is possible to assess the impact of the construction of inlet, intermediate and outlet chambers on the flow distribution within the heat exchanger tubes.

  13. Heat transfer in vapour-liquid flow of carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Yagov, V.V. [Moscow Power Engineering Institute (Technical University), Moscow (Russian Federation)], e-mail: YagovVV@mpei.ru

    2009-07-01

    During the last decade a number of studies of boiling heat transfer in carbon dioxide notably increase. As a field of CO{sub 2} practical using corresponds to high reduced pressures, and a majority of available experimental data on CO{sub 2} flow boiling even in submillimetric channels relate to turbulent liquid flow regimes, a possibility arises to develop sufficiently general method for HTC predicting. Under the above conditions nucleate boiling occurs up to rather high flow quality, even in annular flow regime due to extremely small size of an equilibrium vapour bubble. This conclusion is in agreement with the available experimental data. The predicting equation for nucleate boiling heat transfer developed by the present author in 1988 is valid for any nonmetallic liquid. A contribution of forced convection in heat transfer is calculated according to the Petukhov et al. equation with correction factor, which accounted for an effect of velocity increase due to evaporation. This effect can be essential at relatively small heat fluxes and rather high mass flow rates. The Reynolds analogy and homogeneous model are used in order to account for the convective heat transfer augmentation in two-phase flow. Due to low ratio of liquid and vapour densities at high reduced pressures the homogeneous approximation of two-phase flow seems to be warranted. A total heat transfer coefficient is calculated as an interpolated value of boiling and convective HTCs. The experimental data on CO{sub 2} flow boiling related to regimes before heated wall dryout incipience are in rather good agreement with the calculations. (author)

  14. Heat transfer in vapour-liquid flow of carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Yagov, V.V. [Moscow Power Engineering Institute (Technical University), Moscow (Russian Federation)], e-mail: YagovVV@mpei.ru

    2009-07-01

    During the last decade a number of studies of boiling heat transfer in carbon dioxide notably increase. As a field of CO{sub 2} practical using corresponds to high reduced pressures, and a majority of available experimental data on CO{sub 2} flow boiling even in submillimetric channels relate to turbulent liquid flow regimes, a possibility arises to develop sufficiently general method for HTC predicting. Under the above conditions nucleate boiling occurs up to rather high flow quality, even in annular flow regime due to extremely small size of an equilibrium vapour bubble. This conclusion is in agreement with the available experimental data. The predicting equation for nucleate boiling heat transfer developed by the present author in 1988 is valid for any nonmetallic liquid. A contribution of forced convection in heat transfer is calculated according to the Petukhov et al. equation with correction factor, which accounted for an effect of velocity increase due to evaporation. This effect can be essential at relatively small heat fluxes and rather high mass flow rates. The Reynolds analogy and homogeneous model are used in order to account for the convective heat transfer augmentation in two-phase flow. Due to low ratio of liquid and vapour densities at high reduced pressures the homogeneous approximation of two-phase flow seems to be warranted. A total heat transfer coefficient is calculated as an interpolated value of boiling and convective HTCs. The experimental data on CO{sub 2} flow boiling related to regimes before heated wall dryout incipience are in rather good agreement with the calculations. (author)

  15. A fictitious domain method for particulate flows with heat transfer

    NARCIS (Netherlands)

    Yu, Z.; Yu, Zhaosheng; Shao, Xueming; Wachs, Anthony

    2006-01-01

    The distributed-Lagrange-multiplier/fictitious-domain (DLM/FD) method of Glowinski et al. [R. Glowinski, T.-W. Pan, T.I. Hesla, D.D. Joseph, A distributed Lagrange multiplier/fictitious domain method for particulate flows, Int. J. Multiphase Flow 25 (1999) 755–794] is extended to deal with heat

  16. An Immersed Boundary Method for Complex Flow and Heat Transfer

    NARCIS (Netherlands)

    Paravento, F.; Pourquie, M.J.; Boersma, B.J.

    2007-01-01

    The need to predict flow and heat transfer problems requires a flexible and fast tool able to simulate complex geometries without increasing the complexity of the flow solver architecture. Here we use a finite volume code that uses a direct solver with pressure correction. A new immersed boundary me

  17. A fictitious domain method for particulate flows with heat transfer

    NARCIS (Netherlands)

    Yu, Zhaosheng; Shao, Xueming; Wachs, Anthony

    2006-01-01

    The distributed-Lagrange-multiplier/fictitious-domain (DLM/FD) method of Glowinski et al. [R. Glowinski, T.-W. Pan, T.I. Hesla, D.D. Joseph, A distributed Lagrange multiplier/fictitious domain method for particulate flows, Int. J. Multiphase Flow 25 (1999) 755–794] is extended to deal with heat tran

  18. The management of heat flow in deep mines

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Horst [Montanuniv. Leoben (Austria). Dept. Mineral Resources and Petroleum Engineering

    2013-04-15

    With the ever-increasing depth of mines, the management of heat has become a key issue for their design and operation. There are two main sources of heat: heat transfer from the rock mass into the mine workings and heat associated with mining operations. The principles of heat transfer from the rock mass are discussed and basic relationships presented. Sources of heat linked to mining operations are discussed. It is shown that in deep-level mines, heat transfer from the rock mass accounts more than 75 % of total mine heat load. In highly mechanized coal mines, heat from the use of mining machinery is also significant. Some models of heat flow prediction for deep gold mines are presented. It is shown that in the case of deep mines, control of heat flow is more important than increasing refrigeration capacity. Examples of heat flow management methods are given. Furthermore, the paper deals with the effects of heat on the human body and mine cooling strategies for deep mines. In detail the effects of heat on a worker are examined, heat stress and heat tolerance discussed and methods of assessing heat stress in different mining situations presented. Experiences from deep South African gold mines highlight the adverse effects of heat stress environment on safety and labour productivity. The principal methods of cooling of deep and ultra deep mines are discussed. It is shown that auto-compression of ventilation air is a deciding factor governing the choice of surface or underground cooling of ventilation air. In the case of deep and ultra deep mines, the use of chilled service water and ice slurry has shown to be the most cost effective means of mine cooling. In the case of ice slurry as cooling medium advantage is taken of the latent heat of ice which significantly reduces the amount of water required for mine cooling and hence the cost of pumping the water to surface. Cooling strategies for moderately deep, deep and ultra deep mines are discussed. Examples of cooling

  19. Flow impinging effect of critical heat flux and nucleation boiling heat transfer on a downward facing heating surface

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Huai-En; Chen, Mei-Shiue; Chen, Jyun-Wei; Lin, Wei-Keng; Pei, Bau-Shei [National Tsing Hua Univ., Taiwan (China). Inst. of Nuclear Engineering and Science

    2015-05-15

    Boiling heat transfer has a high heat removal capability in convective cooling. However, the heat removal capability of downward-facing boiling is significantly worse than that of upward-facing cases because of the confined buoyancy effect. This study was inspired by the conception of external reactor vessel cooling (ERVC) condition relevant to the in-vessel retention (IVR) design of Westinghouse AP1000 plant. In the present study, a small-scale test facility had been established to investigate the local phenomena of boiling heat transfer under a downward-facing horizontal heated surface with impinging coolant flow. In this study, the surface temperature, heat flux information and several specific scenes of bubbles are taken down throughout the boiling processes for detailed investigation. It is observed that bubbles are confined under the downward-facing heated surface, which causes a worse heat transfer rate and a lower critical heat flux (CHF) limit than upward-facing boiling. Nevertheless, the impinging coolant flow is found to disturb the thermal boundary layer formed by the heated surface, so the CHF increases with an increase of coolant flow rate. In addition, during nucleate boiling, it is discovered that the growth, combination and dissipation of bubbles induce turbulent wakes and therefore enhance the heat transfer capability.

  20. Numerical prediction of flow, heat transfer, turbulence and combustion

    CERN Document Server

    Spalding, D Brian; Pollard, Andrew; Singhal, Ashok K

    1983-01-01

    Numerical Prediction of Flow, Heat Transfer, Turbulence and Combustion: Selected Works of Professor D. Brian Spalding focuses on the many contributions of Professor Spalding on thermodynamics. This compilation of his works is done to honor the professor on the occasion of his 60th birthday. Relatively, the works contained in this book are selected to highlight the genius of Professor Spalding in this field of interest. The book presents various research on combustion, heat transfer, turbulence, and flows. His thinking on separated flows paved the way for the multi-dimensional modeling of turbu

  1. Flow and heat transfer of petal shaped double tube

    Science.gov (United States)

    Shakouchi, Toshihiko; Kawashima, Yuki; Tsujimoto, Koichi; Ando, Toshitake

    2014-06-01

    In this study, the flow and heat transfer characteristics of petal-shaped double tube with 6 petals are examined experimentally for a compact heat exchanger. As results, the heat transfer rate, Q, of the 6 petal shaped double tube (6-p tube) is much larger than that, Qp, of conventional circular double tube in all Reynolds number Rein,h (where, the reference length is hydraulic diameter) ranges. For example, at Rein,h =(0.5~1.0)× 104 it is about 4 times of Qp. The heat transfer enhancement of 6-p tube is by the increase of heat transfer area, wetting perimeter, and a highly fluctuating flow, and Q of the 6-p tube can be expressed by Q [kW/m] = 0.54Rein,h + 2245.

  2. DNS of turbulent channel flow subject to oscillatory heat flux

    Directory of Open Access Journals (Sweden)

    Bukhvostova Anastasia

    2014-01-01

    Full Text Available In this paper we study the heat transfer in a turbulent channel flow, which is periodically heated through its walls. We consider the flow of air and water vapor using direct numerical simulation. We consider the fluid as a compressible Newtonian gas. We focus on the heat transfer properties of the system, e.g., the temperature difference between the walls and the Nusselt number. We consider the dependence of these quantities on the frequency of the applied heat flux. We observe that the mean temperature difference is quite insensitive to the frequency and that the amplitude of its oscillations is such that its value multiplied by the square root of frequency is approximately constant. Next we add droplets to the channel, which can undergo phase transitions. The heat transfer properties of the channel in the case with droplets are found to increase by more than a factor of two, compared to the situation without droplets.

  3. A novel compact heat exchanger using gap flow mechanism

    Science.gov (United States)

    Liang, J. S.; Zhang, Y.; Wang, D. Z.; Luo, T. P.; Ren, T. Q.

    2015-02-01

    A novel, compact gap-flow heat exchanger (GFHE) using heat-transfer fluid (HTF) was developed in this paper. The detail design of the GFHE coaxial structure which forms the annular gap passage for HTF is presented. Computational fluid dynamics simulations were introduced into the design to determine the impacts of the gap width and the HTF flow rate on the GFHE performance. A comparative study on the GFHE heating rate, with the gap widths ranged from 0.1 to 1.0 mm and the HTF flow rates ranged from 100 to 500 ml/min, was carried out. Results show that a narrower gap passage and a higher HTF flow rate can yield a higher average heating rate in GFHE. However, considering the compromise between the GFHE heating rate and the HTF pressure drop along the gap, a 0.4 mm gap width is preferred. A testing loop was also set up to experimentally evaluate the GFHE capability. The testing results show that, by using 0.4 mm gap width and 500 ml/min HTF flow rate, the maximum heating rate in the working chamber of the as-made GFHE can reach 18 °C/min, and the average temperature change rates in the heating and cooling processes of the thermal cycle test were recorded as 6.5 and 5.4 °C/min, respectively. These temperature change rates can well satisfy the standard of IEC 60068-2-14:2009 and show that the GFHE developed in this work has sufficient heat exchange capacity and can be used as an ideal compact heat exchanger in small volume desktop thermal fatigue test apparatus.

  4. A survey of oscillating flow in Stirling engine heat exchangers

    Science.gov (United States)

    Simon, Terrence W.; Seume, Jorge R.

    1988-01-01

    Similarity parameters for characterizing the effect of flow oscillation on wall shear stress, viscous dissipation, pressure drop and heat transfer rates are proposed. They are based on physical agruments and are derived by normalizing the governing equations. The literature on oscillating duct flows, regenerator and porous media flows is surveyed. The operating characteristics of the heat exchanger of eleven Stirling engines are discribed in terms of the similarity parameters. Previous experimental and analytical results are discussed in terms of these parameters and used to estimate the nature of the oscillating flow under engine operating conditions. The operating points for many of the modern Stirling engines are in or near the laminar to turbulent transition region. In several engines, working fluid does not pass entirely through heat exchangers during a cycle. Questions that need to be addressed by further research are identified.

  5. Experimental investigation on Heat Transfer Performance of Annular Flow Path Heat Pipe

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Guk; Kim, Kyung Mo; Jeong, Yeong Shin; Bang, In Cheol [UNIST, Ulsan (Korea, Republic of)

    2015-05-15

    Mochizuki et al. was suggested the passive cooling system to spent nuclear fuel pool. Detail analysis of various heat pipe design cases was studied to determine the heat pipes cooling performance. Wang et al. suggested the concept PRHRS of MSR using sodium heat pipes, and the transient performance of high temperature sodium heat pipe was numerically simulated in the case of MSR accident. The meltdown at the Fukushima Daiichi nuclear power plants alarmed to the dangers of station blackout (SBO) accident. After the SBO accident, passive decay heat removal systems have been investigated to prevent the severe accidents. Mochizuki et al. suggested the heat pipes cooling system using loop heat pipes for decay heat removal cooling and analysis of heat pipe thermal resistance for boiling water reactor (BWR). The decay heat removal systems for pressurized water reactor (PWR) were suggested using natural convection mechanisms and modification of PWR design. Our group suggested the concept of a hybrid heat pipe with control rod as Passive IN-core Cooling System (PINCs) for decay heat removal for advanced nuclear power plant. Hybrid heat pipe is the combination of the heat pipe and control rod. In the present research, the main objective is to investigate the effect of the inner structure to the heat transfer performance of heat pipe containing neutron absorber material, B{sub 4}C. The main objective is to investigate the effect of the inner structure in heat pipe to the heat transfer performance with annular flow path. ABS pellet was used instead of B{sub 4}C pellet as cylindrical structures. The thermal performances of each heat pipes were measured experimentally. Among them, concentric heat pipe showed the best performance compared with others. 1. Annular evaporation section heat pipe and annular flow path heat pipe showed heat transfer degradation. 2. AHP also had annular vapor space and contact cooling surface per unit volume of vapor was increased. Heat transfer

  6. Analysis of flow and heat transfer characteristics of porous heat-storage wall in greenhouse

    Institute of Scientific and Technical Information of China (English)

    Li OUYANG; Wei LIU

    2008-01-01

    The flow and heat transfer characteristics of porous heat-storage wall in greenhouse are studied by using the one-dimensional steady energy two-equation model for saturated porous medium. The results show that the heat exchange between the air and the solid matrix of the porous heat-storage wall depends upon the inlet air velocity, the porosity and the permeability of porous medium, and the thermal conductivity of the solid matrix. Because the incidence of solar radiation on the porous heat-storage wall is not uniform, the new compos-ite porous solar wall with different porosity is proposed to reduce the disadvantageous effect.

  7. Flow and Heat Transfer Characteristics of the Staggered Slotted Semi Cylinders in a Cross Flow Heat Exchangers

    Science.gov (United States)

    Yayla, Sedat; Beyin, Seyfettin; Oztekin, Alparslan

    2012-11-01

    Transient 3-D dimensional turbulent flow simulations are conducted to examine flow and heat transfer characteristics in inline and staggered slotted semi-cylinders placed in a rectangular cross sectioned fin tube heat exchanger. Both Reynolds averaged Navier's equation and Large Eddy simulations model are employed to conduct simulations using Fluent-ANSYS. Predictions of transient simulations are compared against the results of the PIV flow visualization observations at Reynolds number 1500 and 4000. Measured and predicted velocity and the vorticity field in the wake of cylinders agree well with each other at both Reynolds number. The effect of the angle between the slotted semi cylinders and the flow direction is investigated for various values of Reynolds number in both laminar and turbulent flow regimes. Transient nature of the three dimensional flow structures with flow separation, reattachment and vortices are characterized. The effects of the flow structure on the heat transfer characteristics are determined by calculating the heat transfer coefficient along the surface of the semi cylinders.

  8. Heat Flow Pattern and Thermal Resistance Modeling of Anisotropic Heat Spreaders

    Science.gov (United States)

    Falakzaadeh, F.; Mehryar, R.

    2017-01-01

    To ensure safe operating temperatures of the ever smaller heat generating electronic devices, drastic measures should be taken. Heat spreaders are used to increase surface area, by spreading the heat without necessarily transferring it to the ambient in the first place. The heat flow pattern is investigated in heat spreaders and the fundamental differences regarding how heat conducts in different materials is addressed. Isotropic materials are compared with anisotropic ones having a specifically higher in-plane thermal conductivity than through plane direction. Thermal resistance models are proposed for anisotropic and isotropic heat spreaders in compliance with the order of magnitude of dimensions used in electronics packaging. After establishing thermal resistance models for both the isotropic and anisotropic cases, numerical results are used to find a correlation for predicting thermal resistance in anisotropic heat spreaders with high anisotropy ratios.

  9. Heat transfer intensification by increasing vapor flow rate in flat heat pipes

    Science.gov (United States)

    Sprinceana, Silviu; Mihai, Ioan; Beniuga, Marius; Suciu, Cornel

    2015-02-01

    Flat heat pipes have various technical applications, one of the most important being the cooling of electronic components[9]. Their continuous development is due to the fact that these devices permit heat transfer without external energetic contribution. The practical exploitation of flat heat pipes however is limited by the fact that dissipated power can only reach a few hundred watts. The present paper aims to advance a new method for the intensification of convective heat transfer. A centrifugal mini impeller, driven by a turntable which incorporates four permanent magnets was designed. These magnets are put in motion by another rotor, which in its turn includes two permanent magnets and is driven by a mini electrical motor. Rotation of the centrifugal blades generates speed and pressure increase of the cooling agent brought to vapor state within the flat micro heat pipe. It's well known that the liquid suffers biphasic transformations during heat transfer inside the heat pipe. Over the hotspot (the heat source being the electronic component) generated at one end of the heat pipe, convective heat transfer occurs, leading to sudden vaporization of the liquid. Pressures generated by newly formed vapors push them towards the opposite end of the flat heat pipe, where a finned mini heat sink is usually placed. The mini-heat exchanger is air-cooled, thus creating a cold spot, where vapors condensate. The proposed method contributes to vapor flow intensification by increasing their transport speed and thus leading to more intense cooling of the heat pipe.

  10. Heat flow, heat transfer and lithosphere rheology in geothermal areas: Features and examples

    Science.gov (United States)

    Ranalli, G.; Rybach, L.

    2005-10-01

    Surface heat flow measurements over active geothermal systems indicate strongly positive thermal anomalies. Whereas in "normal" geothermal settings, the surface heat flow is usually below 100-120 mW m - 2 , in active geothermal areas heat flow values as high as several watts per meter squared can be found. Systematic interpretation of heat flow patterns sheds light on heat transfer mechanisms at depth on different lateral, depth and time scales. Borehole temperature profiles in active geothermal areas show various signs of subsurface fluid movement, depending on position in the active system. The heat transfer regime is dominated by heat advection (mainly free convection). The onset of free convection depends on various factors, such as permeability, temperature gradient and fluid properties. The features of heat transfer are different for single or two-phase flow. Characteristic heat flow and heat transfer features in active geothermal systems are demonstrated by examples from Iceland, Italy, New Zealand and the USA. Two main factors affect the rheology of the lithosphere in active geothermal areas: steep temperature gradients and high pore fluid pressures. Combined with lithology and structure, these factors result in a rheological zonation with important consequences both for geodynamic processes and for the exploitation of geothermal energy. As a consequence of anomalously high temperature, the mechanical lithosphere is thin and its total strength can be reduced by almost one order of magnitude with respect to the average strength of continental lithosphere of comparable age and thickness. The top of the brittle/ductile transition is located within the upper crust at depths less than 10 km, acts as the root zone of listric normal faults in extensional environments and, at least in some cases, is visible on seismic reflection lines. These structural and rheological features are well illustrated in the Larderello geothermal field in Tuscany.

  11. Influence of System Variables on the Heating Characteristics of Water during Continuous Flow Microwave Heating

    Directory of Open Access Journals (Sweden)

    Hosahalli S. Ramaswamy

    2011-01-01

    Full Text Available A domestic microwave oven (1000 W was modified to permit the continuous flow of liquids run through a helical coil centrally located inside the oven cavity. Heating characteristics were evaluated by measuring inlet and outlet temperatures of coil as a function of system variables. The influence of number of turns, coil diameter, tube diameter, pitch and initial temperature were evaluated at different flow rates. The average residence time of water was computed by dividing the coil volume by the volumetric flow rate. The influence of Dean number was evaluated. Results from this study showed that (1 higher number of turns resulted in lower heating rate, lower temperature fluctuations, higher exit temperature and longer time to achieve temperature equilibrium; (2 larger tube or coil diameter gave larger coil volume causing the heating rate to decrease; (3 faster flow rates resulted in lower exit temperatures, lower temperature fluctuation, higher Dean number and slightly higher heating rate; (4 higher initial temperatures resulted in higher exit temperatures; (5 higher Dean number resulted in more uniform heating and slightly higher heating rate. Overall, the coil volume was the more dominant factor affecting heating rate as compared with flow rate and Dean number.

  12. Convective Heat Transfer Analysis in Fluid Flow with Turbulence Promoters with Heat Pipes

    Directory of Open Access Journals (Sweden)

    Theodor Mateescu

    2007-01-01

    Full Text Available The present paper proposes the analysis and the simulation of the convection heat transfer into the fluid flow with turbulence promoters utilizing heat pipes. The study is based on the necesity of the unconventional energy forms capitalization, increasing of the energy efficiency and leads to the energy consumtion decrease in concordance with the sustainable development concept.

  13. Modeling heat efficiency, flow and scale-up in the corotating disc scraped surface heat exchanger

    DEFF Research Database (Denmark)

    Friis, Alan; Szabo, Peter; Karlson, Torben

    2002-01-01

    A comparison of two different scale corotating disc scraped surface heat exchangers (CDHE) was performed experimentally. The findings were compared to predictions from a finite element model. We find that the model predicts well the flow pattern of the two CDHE's investigated. The heat transfer...

  14. Analysis of the heat transfer in unsymmetrically heated triangular microchannels in slip flow regime

    Institute of Scientific and Technical Information of China (English)

    ZHU; Xun; LIAO; Qiang; XIN; Mingdao

    2004-01-01

    A theoretical analysis of heat transfer characteristics is presented for the fully developed laminar flow of the incompressible gas in the triangular microchannels heated unsymmetrically with constant axial heat flux. Through solving the energy equation with temperature jump boundary conditions in slip flow regime by virtue of a computationoriented method of the orthonormal function analysis, the dimensionless temperature profiles and the average Nusselt number for various thermal boundary conditions are obtained. The effects of Knudsen number, aspect ratio, and thermal boundary conditions on the heat transfer are discussed. The calculated results show that the orthonormal function method can be used to study the heat transfer characteristics of the unsymmetrically heated triangular microchannels. The average Nusselt number in triangular microchannels is lower for slip flow than for no-slip flow, and decreases with increasing Knudsen number. The aspect ratios and thermal boundary conditions of triangular microchannels have significant influences on the change of average Nusselt numbers with the increase in the Knudsen number. For the equilateral triangular microchannels, the decrease of the Nusselt number ratio due to temperature jump is smaller at large Knudsen number and larger at small Knudsen number on the boundary condition of bottom wall heated alone as compared with the one on the boundary condition of two heated hypotenuse walls. The correlations of the average Nusselt number with the Knudsen number for equilateral triangular microchannels are obtained.

  15. Heat flow through the sea bottom around the Yucatan Peninsula

    Energy Technology Data Exchange (ETDEWEB)

    Khutorskoy, M.D.; Kononov, V.I.; Polyak, B.G. (Geological Inst., Moscow (USSR)); Fernandez, R. (Centro de Investigacion Cientifica y Educacion Superior de Ensenada, Baja California (Mexico)); Matveev, V.G.; Rot, A.A. (Polytechnical Inst., Kuybyshev (USSR))

    1990-02-10

    Heat flow studies were conducted in January-February 1987, off the Atlantic Coast of Mexico on board the R/V Akademik Nikolai Strakhov. Two areas were surveyed, one transecting the Salt Dome Province and the Campeche Canyon, in the Gulf of Mexico, and the other, on the eastern flank of the Yucatan Peninsula. Conductive heat flow through the bottom sediments was determined as the product of vertical temperature gradient and in situ thermal conductivity, measured with a thermal probe using a multithermistor array and real-time processing capabilities. Forward two-dimensional modeling allows one to estimate heat flow variations at both sites from local disturbances and to obtain average heat flow values of 51 mW/m{sup 2} for the transect within the Gulf of Mexico and 38 and 69 mW/m{sup 2} for two basins within the Yucatan area. Sea bottom relief has a predominant effect over other environmental factors in the scatter of heat flow determination in the Gulf of Mexico.

  16. Flow Structure and Heat Transfer Between Two Disks Rotating Independently

    Institute of Scientific and Technical Information of China (English)

    Chyi-Yeou Soong

    2003-01-01

    In the present paper, fluid flow and convective heat transfer between two co-axial disks rotating independently are dealt with mainly based on the author's recent research on that topic. Three rotational modes, i.e. co-rotation, rotor-stator, and counter-rotation, are considered. Theory of rotating non-isothermal fluids with the presence of disk rotation and thermal effects is addressed. Rotational buoyancy effects on the flow structure development are highlighted. Results of flow visualization and heat transfer measurements are discussed to explore the thermal flow mechanisms involved in the two-disk flows at various rotational and geometric conditions. Potential issues open to the future investigation are also proposed.

  17. Flow instability and critical heat flux for downward flow in a vertical narrow rectangular channel heated from both-sides

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Juhyung; Chang, Soon Heung [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Jo, Daeseong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    Subcooled flow boiling in a vertical rectangular channel was experimentally investigated to enhance the understanding of the CHF and the effect of the two-phase flow instability on it under low pressure conditions, especially for downward flow which was adopted for Jordan Research and Training Reactor (JRTR) and Kijang research reactor (KJRR) to achieve easier fuel and irradiation rig loading. In addition, visual observations of subcoold flow boiling was conducted by using high-speed video (HSV) for a clear understanding of both phenomena. We concluded that flow excursion (which is static instability) could be induced due to the OPDF (which is dynamic instability) when a system has no resistibility to the pressure drop perturbation, which is caused by the coalescence of facing bubbles on opposing heated surfaces. In more stable system with throttling applied, flow rate could be maintained and stable CHF could be reached. The static flow instability (FI) and critical heat flux (CHF) for subcooled flow boiling in a vertical narrow channels under low pressure condition are fairly crucial phenomena relative to thermal-hydraulic design and safety analysis for pool-type research reactors. It has been recommended that RRs and MTRs be designed to have sufficient margins for CHF and the onset of FI as well, since unstable flow could leads to premature CHF under very low wall heat flux in comparison to stable CHF. Even the fact and previous studies, however, the understanding of relationship among FI, premature CHF and stable CHF is not sufficient to date.

  18. A heat transfer model for slug flow boiling within microchannels

    Science.gov (United States)

    Magnini, Mirco; Thome, John

    2016-11-01

    We propose a novel physics-based model for the fluid mechanics and heat transfer associated with slug flow boiling in horizontal circular microchannels, to update the widely used three-zone model for the design of multi-microchannel evaporators. The flow is modelled as the cyclic passage of a liquid slug, an elongated bubble which traps a thin liquid film against the channel wall, and a dry vapor plug. The capillary flow theory, extended to incorporate evaporation effects, is applied to estimate the bubble velocity along the channel. A liquid film thickness prediction method considering bubble proximity effects, which may limit the radial extension of the film, is included. Theoretical heat transfer models accounting for the thermal inertia of the liquid film and for the recirculating flow within the liquid slug are utilized. The heat transfer model is compared to experimental data taken from three independent studies: 833 slug flow boiling data points covering R134a, R245fa and R236fa and channel diameters from 0.4 mm to 1 mm. The new model predicts more than 80% of the database to within +/- 30 % and it represents an important step toward a complete physics-based modelling of bubble dynamics and heat transfer within microchannels under evaporating flow conditions.

  19. Diffusive heat and mass transfer in oscillatory pipe flow

    Science.gov (United States)

    Brereton, G. J.; Jalil, S. M.

    2017-07-01

    The enhancement of axial heat and mass transfer by laminar flow oscillation in pipes with axial gradients in temperature and concentration has been studied analytically for the cases of insulated and conducting walls. The axial diffusivity can exceed its molecular counterpart by many orders of magnitude, with a quadratic scaling on the pressure-gradient amplitude and the Prandtl or Schmidt number, and is a bimodal function of oscillatory frequency: quasi-steady behavior at low frequencies and a power-law decay at high frequencies. When the pipe wall is conductive and of sufficient thickness, and the flow oscillation is quasi-steady, the axial diffusivity may be enhanced by a further factor of about ten as a result of increased radial diffusion, for liquid and gas flows in pipes with walls with a wide range of thermal conductivities. Criteria for the wall thickness required to achieve this additional enhancement and for the limits placed on the validity of these solutions by viscous dissipation are also deduced. When the heat transfer per unit flow work achieved by oscillatory pipe flow is contrasted with that of a conventional parallel-flow heat exchanger, it is found to be of comparable size and the ratio of the two is shown to be a function only of the pipe geometry, heat-exchanger mean velocity, and fluid viscosity.

  20. Brine flow in heated geologic salt.

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlman, Kristopher L.; Malama, Bwalya

    2013-03-01

    This report is a summary of the physical processes, primary governing equations, solution approaches, and historic testing related to brine migration in geologic salt. Although most information presented in this report is not new, we synthesize a large amount of material scattered across dozens of laboratory reports, journal papers, conference proceedings, and textbooks. We present a mathematical description of the governing brine flow mechanisms in geologic salt. We outline the general coupled thermal, multi-phase hydrologic, and mechanical processes. We derive these processes governing equations, which can be used to predict brine flow. These equations are valid under a wide variety of conditions applicable to radioactive waste disposal in rooms and boreholes excavated into geologic salt.

  1. Thermal and Hydraulic Performances of Nanofluids Flow in Microchannel Heat Sink with Multiple Zigzag Flow Channels

    OpenAIRE

    Duangthongsuk Weerapun

    2017-01-01

    This article presents an experimental investigation on the heat transfer performance and pressure drop characteristic of two types of nanofluids flowing through microchannel heat sink with multiple zigzag flow channel structures (MZMCHS). SiO2 nanoparticles dispersed in DI water with concentrations of 0.3 and 0.6 vol.% were used as working fluid. MZMCHS made from copper material with dimension of 28 × 33 mm. Hydraulic diameter of MZMCHs is designed at 1 mm, 7 number of flow channels and heat ...

  2. Heat transfer from cylinders in subsonic slip flows

    Science.gov (United States)

    Nagabushana, K. A.; Stainback, P. C.

    1992-01-01

    The heat transfer in heated wires was measured using a constant temperature anemometer over a Mach number range from 0.05 to 0.4 and pressures from 0.5 to 8.0 atmospheres. The total temperature ranged from 80 to 120 F and the wire diameters were 0.00015, 0.00032, and 0.00050 inch. The heat transfer data is presented in the form of a corrected Nusselt number. Based on suggested criteria, much of the data was obtained in the slip flow regime. Therefore, the data is compared with data having comparable flow conditions. The possible application of the heat transfer data to hot wire anemometry is discussed. To this end, the sensitivity of the wires to velocity, density, and total temperature is computed and compared using two different types of correlations.

  3. Performance of parallel flow HeII heat exchangers

    Science.gov (United States)

    Huang, Y.; Chang, Y.; Witt, R. J.; Van Sciver, S. W.

    Previous studies of HeII heat exchangers have focused on tube-in-shell designs. The present paper examines the properties of a parallel flow HeII heat exchanger formed from two 254 mm lengths of copper channel having nominal rectangular dimensions 2 mm × 4 mm. Heaters positioned at the inlets and outlets of both channels permit the simulation of a variety of physically plausible boundary conditions. An iterative numerical method, based on one-dimensional energy balances in each channel with coupling through a heat transfer term, is presented and agrees well with the experimental results. As with tube-in-shell designs, parallel flow HeII heat exchangers may exhibit unusual temperature profiles.

  4. Analysis of radiative heat transfer impact in cross-flow tube and fin heat exchangers

    Science.gov (United States)

    Hanuszkiewicz-Drapała, Małgorzata; Bury, Tomasz; Widziewicz, Katarzyna

    2016-03-01

    A cross-flow, tube and fin heat exchanger of the water - air type is the subject of the analysis. The analysis had experimental and computational form and was aimed for evaluation of radiative heat transfer impact on the heat exchanger performance. The main element of the test facility was an enlarged recurrent segment of the heat exchanger under consideration. The main results of measurements are heat transfer rates, as well as temperature distributions on the surface of the first fin obtained by using the infrared camera. The experimental results have been next compared to computational ones coming from a numerical model of the test station. The model has been elaborated using computational fluid dynamics software. The computations have been accomplished for two cases: without radiative heat transfer and taking this phenomenon into account. Evaluation of the radiative heat transfer impact in considered system has been done by comparing all the received results.

  5. Analysis of radiative heat transfer impact in cross-flow tube and fin heat exchangers

    Directory of Open Access Journals (Sweden)

    Hanuszkiewicz-Drapała Małgorzata

    2016-03-01

    Full Text Available A cross-flow, tube and fin heat exchanger of the water – air type is the subject of the analysis. The analysis had experimental and computational form and was aimed for evaluation of radiative heat transfer impact on the heat exchanger performance. The main element of the test facility was an enlarged recurrent segment of the heat exchanger under consideration. The main results of measurements are heat transfer rates, as well as temperature distributions on the surface of the first fin obtained by using the infrared camera. The experimental results have been next compared to computational ones coming from a numerical model of the test station. The model has been elaborated using computational fluid dynamics software. The computations have been accomplished for two cases: without radiative heat transfer and taking this phenomenon into account. Evaluation of the radiative heat transfer impact in considered system has been done by comparing all the received results.

  6. Local Fractional Fourier Series Solutions for Nonhomogeneous Heat Equations Arising in Fractal Heat Flow with Local Fractional Derivative

    Directory of Open Access Journals (Sweden)

    Ai-Min Yang

    2014-03-01

    Full Text Available The fractal heat flow within local fractional derivative is investigated. The nonhomogeneous heat equations arising in fractal heat flow are discussed. The local fractional Fourier series solutions for one-dimensional nonhomogeneous heat equations are obtained. The nondifferentiable series solutions are given to show the efficiency and implementation of the present method.

  7. Bubbles as tracers of heat input to cooling flows

    CERN Document Server

    Binney, J; Omma, H

    2007-01-01

    We examine the distribution of injected energy in three-dimensional, adaptive-grid simulations of the heating of cooling flows. We show that less than 10 percent of the injected energy goes into bubbles. Consequently, the energy input from the nucleus is underestimated by a factor of order 6 when it is taken to be given by PVgamma/(gamma-1), where P and V are the pressure and volume of the bubble, and gamma the ratio of principal specific heats.

  8. Synthesis of Bottom Hole Temperatures and Heat Flow Data

    Science.gov (United States)

    Gosnold, W. D.; Crowell, A. M.

    2012-12-01

    The development of a National Geothermal Data System (http://www.geothermaldata.org/) promises to provide industry, governmental agencies and researchers with a wealth of data on United States geothermal resources. Two of the larger data sets in the NDGS effort are the bottom-hole temperature data set from oil and gas drilling and the heat flow data set. The BHT data are being compiled by state geological surveys in a Bore Hole Observation Template that can include up to 76 different attributes for each well. The heat flow data are being compiled by a consortium led by the SMU Geothermal Laboratory in a Heat Flow Template that can include up to 63 different atrributes for each heat flow site. The key data for geothermal resource development are temperature, depth and the reservoir properties that control production capacity. The UND geothermal laboratory has assembled the BHT and heat flow data sets for North Dakota, Nebraska and Minnesota and we have compared how accurately the key geothermal data may be independently determined from each data set and by synthesis of both data sets. The BHT data provide temperature at depth, but it is well-documented that BHT data were recorded at non-equilibrium conditions and generally underestimate actual formation temperatures. Heat flow data include a measured temperature gradient, although the gradient may apply to only a short segment of the borehole temperature measurement. Synthesis of these two data sets provides checks that can prevent errors in data interpretation. We compared BHT data from the Denver Basin and Williston Basin to equilibrium temperature vs. depth profiles measured in deep boreholes and developed a thermal stratigraphy approach that permits correction of the BHT data for each basin.

  9. Numerical and Experimental Approaches Toward Understanding Lava Flow Heat Transfer

    Science.gov (United States)

    Rumpf, M.; Fagents, S. A.; Hamilton, C.; Crawford, I. A.

    2013-12-01

    We have performed numerical modeling and experimental studies to quantify the heat transfer from a lava flow into an underlying particulate substrate. This project was initially motivated by a desire to understand the transfer of heat from a lava flow into the lunar regolith. Ancient regolith deposits that have been protected by a lava flow may contain ancient solar wind, solar flare, and galactic cosmic ray products that can give insight into the history of our solar system, provided the records were not heated and destroyed by the overlying lava flow. In addition, lava-substrate interaction is an important aspect of lava fluid dynamics that requires consideration in lava emplacement models Our numerical model determines the depth to which the heat pulse will penetrate beneath a lava flow into the underlying substrate. Rigorous treatment of the temperature dependence of lava and substrate thermal conductivity and specific heat capacity, density, and latent heat release are imperative to an accurate model. Experiments were conducted to verify the numerical model. Experimental containers with interior dimensions of 20 x 20 x 25 cm were constructed from 1 inch thick calcium silicate sheeting. For initial experiments, boxes were packed with lunar regolith simulant (GSC-1) to a depth of 15 cm with thermocouples embedded at regular intervals. Basalt collected at Kilauea Volcano, HI, was melted in a gas forge and poured directly onto the simulant. Initial lava temperatures ranged from ~1200 to 1300 °C. The system was allowed to cool while internal temperatures were monitored by a thermocouple array and external temperatures were monitored by a Forward Looking Infrared (FLIR) video camera. Numerical simulations of the experiments elucidate the details of lava latent heat release and constrain the temperature-dependence of the thermal conductivity of the particulate substrate. The temperature-dependence of thermal conductivity of particulate material is not well known

  10. Modelling of convective heat and mass transfer in rotating flows

    CERN Document Server

    Shevchuk, Igor V

    2016-01-01

     This monograph presents results of the analytical and numerical modeling of convective heat and mass transfer in different rotating flows caused by (i) system rotation, (ii) swirl flows due to swirl generators, and (iii) surface curvature in turns and bends. Volume forces (i.e. centrifugal and Coriolis forces), which influence the flow pattern, emerge in all of these rotating flows. The main part of this work deals with rotating flows caused by system rotation, which includes several rotating-disk configurations and straight pipes rotating about a parallel axis. Swirl flows are studied in some of the configurations mentioned above. Curvilinear flows are investigated in different geometries of two-pass ribbed and smooth channels with 180° bends. The author demonstrates that the complex phenomena of fluid flow and convective heat transfer in rotating flows can be successfully simulated using not only the universal CFD methodology, but in certain cases by means of the integral methods, self-similar and analyt...

  11. Convective heat flow in space cryogenics plugs - Critical and moderate He II heat flux densities

    Science.gov (United States)

    Yuan, S. W. K.; Frederking, T. H. K.

    1990-01-01

    Plug flow rates of entropy, heat and normal fluid in phase separators and in zero net mass flow systems are, to some extent, quite similar. A simplified analysis of critical conditions is presented in agreement with data trends. A critical temperature gradient arises on the basis of the He II two-fluid model at the stability limit constraining the thermohydrodynamics of the system. Thus, the question of critical thermodynamic fluctuations associated with nucleation versus the possibility of critical gradients in externally imposed parameters is answered in favor of the latter route toward turbulence. Furthermore, a similarity equation is presented which incorporates size dependent rates for moderate heat flow densities observed in experiments.

  12. New shear-free relativistic models with heat flow

    CERN Document Server

    Msomi, A M; Maharaj, S D

    2013-01-01

    We study shear-free spherically symmetric relativistic models with heat flow. Our analysis is based on Lie's theory of extended groups applied to the governing field equations. In particular, we generate a five-parameter family of transformations which enables us to map existing solutions to new solutions. All known solutions of Einstein equations with heat flow can therefore produce infinite families of new solutions. In addition, we provide two new classes of solutions utilising the Lie infinitesimal generators. These solutions generate an infinite class of solutions given any one of the two unknown metric functions.

  13. Analytical heat and fluid flow in microchannels and microsystems

    CERN Document Server

    Cotta, Renato M; Naveira-Cotta, Carolina P

    2016-01-01

    This book focuses on the modeling and analysis of heat and fluid flow in microchannels and micro-systems, compiling a number of analytical and hybrid numerical-analytical solutions for models that account for the relevant micro-scale effects, with the corresponding experimental analysis validation when applicable. The volume stands as the only available compilation of easy to use analytically-based solutions for micro-scale heat and fluid flow problems, that systematically incorporates the most relevant micro-scale effects into the mathematical models, followed by their physical interpretation on the micro-system behavior.

  14. Preliminary heat flow map of Europe. Explanatory text

    Energy Technology Data Exchange (ETDEWEB)

    Cermak, V.; Hurtig, E.

    1977-08-08

    A preliminary heat flow map of Europe was prepared, based on data contained in 401 references. The map was prepared on a scale of 1:5,000,000 and shows broad-scale geological structure (e.g., platforms, shields, foredeeps) and specialized rock suites (ophiolites, volcanites). Primary faults and thrust faults are indicated, and contours showing the depth of crystalline basement are given. Heat flow is plotted using 10.0 mW/m/sup 2/ isotherms. The accompanying explanatory text describes data acquisition and techniques of correction, and discusses some implications of the results.

  15. Flow Pattern and Heat Transfer Behavior of Boiling Two—Phase flow in Inclined Pipes

    Institute of Scientific and Technical Information of China (English)

    LiuDezhang; OuyangNing

    1992-01-01

    Movable Electrical Conducting Probe (MECP),a kind of simple and reliable measuring transducer,used for predicting full-flow-path flow pattern in a boiling vapor/liquid two-phase flow is introduced in this paper when the test pipe is set at different inclination angles,several kinds of flow patterns,such as bubble,slug,churn,intermittent,and annular flows,may be observed in accordance with the locations of MECP.By means of flow pattern analysis,flow fleld numerical calculations have been carried out,and heat transfer coeffcient correlations along full-flow-path derived.The results show that heat transfer performance of boiling two-phase flow could be significanfly augmanted as expected in some flow pattern zones.The results of the investigation,measuring techniques and conclusions contained in this paper would be a useful reference in foundational research for prediction of flow pattern and heat transfer behavior in boiling two-phase flow,as well as for turbine vane liquid-cooling design.

  16. Heat Transfer & Periodic Flow Analysis of Heat Exchanger by CFD with Nano Fluids

    Directory of Open Access Journals (Sweden)

    Mr.V.V.Ramakrishna

    2016-01-01

    Full Text Available Many heat transfer applications such as steam generators in a boiler or air cooling coil of an air conditioner, can be modelled in a bank of tubes containing a fluid flowing at one temperature that is immersed in a second fluid in a cross flow at different temperature. CFD simulations are a useful tool for understanding flow and heat transfer principles as well as for modelling these types of geometries. Both the fluids considered in the present study are CUO Nano fluids, and flow is classified as laminar and steady with Reynolds number between 100- 600.The mass flow rate of the cross flow and diameter has been varied (such as 0.05, 0.1, 0.15, 0.20, 0.25, 0.30 kg/sec and 0.8, 1.0.1.2 &1.4cm and the models are used to predict the flow and temperature fields that result from convective heat transfer. Due to symmetry of the tube bank and the periodicity of the flow inherent in the tube bank geometry, only a portion of the geometry will be modelled and with symmetry applied to the outer boundaries. The inflow boundary will be redefined as a periodic zone and the outflow boundary is defined as the shadow. The various static pressures, velocities, and temperatures obtained are reported. In this present project tubes of different diameters and different mass flow rates are considered to examine the optimal flow distribution. Further the problem has been subjected to effect of materials used for tubes manufacturing on heat transfer rate. Materials considered are copper and Nickle Chromium alloys. Results emphasize the utilization of alloys in place of copper as tube material serves better heat transfer with most economical way.

  17. An experimental investigation of heat-transfer and flow in channels with streamwise-periodic flow

    Energy Technology Data Exchange (ETDEWEB)

    Habib, M.A. (King Fahd Univ. of Petroleum and Minerals, Dhahran (Saudi Arabia)); Mobarak, A.M.; Attya, A.M.; Aly, A.Z. (Cairo Univ. (Egypt). Faculty of Engineering)

    1992-11-01

    We investigate the enhancement of heat transfer and the consequent conservation of energy in channels with segmented baffles. The influence of Reynolds number, baffle spacing, baffle material, and heat flux on local and average heat-transfer coefficients have been studied. Our results show that the flow must pass over three to six baffles before it becomes periodic and fully-developed. Augmentation of heat transfer was obtained with increases in Reynolds number, thermal conductivity of the baffles and decreases in baffle spacing and wall heat flux. (Author).

  18. Thermal heat-balance mode flow-to-frequency converter

    Science.gov (United States)

    Pawlowski, Eligiusz

    2016-11-01

    This paper presents new type of thermal flow converter with the pulse frequency output. The integrating properties of the temperature sensor have been used, which allowed for realization of pulse frequency modulator with thermal feedback loop, stabilizing temperature of sensor placed in the flowing medium. The system assures balancing of heat amount supplied in impulses to the sensor and heat given up by the sensor in a continuous way to the flowing medium. Therefore the frequency of output impulses is proportional to the heat transfer coefficient from sensor to environment. According to the King's law, the frequency of those impulses is a function of medium flow velocity around the sensor. The special feature of presented solution is total integration of thermal sensor with the measurement signal conditioning system. Sensor and conditioning system are not the separate elements of the measurement circuit, but constitute a whole in form of thermal heat-balance mode flow-to-frequency converter. The advantage of such system is easiness of converting the frequency signal to the digital form, without using any additional analogue-to-digital converters. The frequency signal from the converter may be directly connected to the microprocessor input, which with use of standard built-in counters may convert the frequency into numerical value of high precision. Moreover, the frequency signal has higher resistance to interference than the voltage signal and may be transmitted to remote locations without the information loss.

  19. FLOW RESISTANCE AND HEAT TRANSFER CHARACTERISTICS OF A NEW-TYPE PLATE HEAT EXCHANGER

    Institute of Scientific and Technical Information of China (English)

    LUAN Zhi-jian; ZHANG Guan-min; TIAN Mao-cheng; FAN Ming-xiu

    2008-01-01

    A new-type corrugation Plate Heat Exchanger (PHE) was designed. Results from both numerical simulations and experiments showed that the flow resistance of the working fluid in this new corrugation PHE, compared with the traditional chevron-type one, was decreased by more than 50%, and corresponding heat transfer performance was decreased by about 25%. The flow field of the working fluid in the corrugation PHE was transformed and hence performance difference in both flow resistance and heat transfer was generated. Such a novel plate, consisting of longitudinal and transverse corrugations, can effectively avoid the problem of flow path blockage, which will help to extend the application of PHEs to the situation with unclean working fluids.

  20. MHD Casson nanofluid flow past a wedge with Newtonian heating

    Science.gov (United States)

    Ahmad, Kartini; Hanouf, Zahir; Ishak, Anuar

    2017-02-01

    The problem of steady Casson nanofluid flow past a wedge is studied in this paper. The presence of magnetic field along with Newtonian heating at the surface is considered. The governing partial differential equations are first transformed into a set of nonlinear ordinary differential equations by similarity transformations, before being solved numerically using the Keller-box method. The effects of the wedge angle Ω from 0° (horizontal plate) to 180° (vertical plate) as well as of as the magnetic parameter M on the non-Newtonian fluid flow and heat transfer characteristics are investigated. It is found that the surface temperature is slightly higher for the flow over a horizontal plate compared to that over a vertical plate. It is also found that the magnetic field decreases the surface temperature but increases the skin friction. The flow of a Newtonian fluid is found to give higher skin friction as compared to that of Casson fluid.

  1. Marangoni mixed convection flow with Joule heating and nonlinear radiation

    Directory of Open Access Journals (Sweden)

    Tasawar Hayat

    2015-07-01

    Full Text Available Marangoni mixed convective flow of Casson fluid in a thermally stratified medium is addressed. Flow analysis has been carried out in presence of inclined magnetic field. Heat transfer analysis is discussed in the presence of viscous dissipation, Joule heating and nonlinear thermal radiation. The governing nonlinear partial differential equations are first converted into ordinary differential systems and then developed the convergent series solutions. Flow pattern with the influence of pertinent parameters namely the magnetic parameter, Casson fluid parameter, temperature ratio parameter, stratification parameter, Prandtl number, Eckert number and radiation parameter is investigated. Expression of local Nusselt number is computed and analyzed. It is found that the Nusselt number decreases by increasing magnetic parameter, temperature ratio parameter, angle of inclination and stratification parameter. Moreover the effect of buoyancy parameter on the velocity distribution is opposite in both the opposing and assisting flow phenomena. Thermal field and associated layer thickness are enhanced for larger radiation parameter.

  2. Transient flow and heating characteristics in a pinched plasma column.

    Science.gov (United States)

    York, T. M.; Stover, E. K.

    1972-01-01

    The generation of axial flow and heating of an argon plasma in a pinched plasma column of a pulsed, linear z-pinch device was examined experimentally and analytically. Transient (about 5 microsec) axial pressure profiles identify three characteristic periods in the column history. These include (1) strong axial pressure asymmetry indicative of plasma streaming, (2) isotropic, rapidly rising plasma pressure indicative of plasma heating, and (3) column breakup. An efficient conversion of radial collapse to axial streaming velocity is identified. Mechanisms for such an effect and subsequent heating are evaluated; significance to transients in pulsed plasma accelerators is identified.

  3. A fictitious domain method for particulate flows with heat transfer

    Science.gov (United States)

    Yu, Zhaosheng; Shao, Xueming; Wachs, Anthony

    2006-09-01

    The distributed-Lagrange-multiplier/fictitious-domain (DLM/FD) method of Glowinski et al. [R. Glowinski, T.-W. Pan, T.I. Hesla, D.D. Joseph, A distributed Lagrange multiplier/fictitious domain method for particulate flows, Int. J. Multiphase Flow 25 (1999) 755-794] is extended to deal with heat transfer in particulate flows in two dimensions. The Boussinesq approximation is employed for the coupling between the flow and temperature fields. The fluid-flow equations are solved with the finite-difference projection method on a half-staggered grid. In our operator splitting scheme, the Lagrange multipliers at the previous time level are kept in the fluid equations, and the new Lagrange multipliers for the rigid-body motion constraint and the Dirichlet temperature boundary condition are determined from the reduced saddle-point problem, whereas a very simple scheme based on the fully explicit computation of the Lagrange multiplier is proposed for the problem in which the solid heat conduction inside the particle boundary is also considered. Our code for the case of fixed temperature on the immersed boundary is verified by comparing favorably our results on the natural convection driven by a hot cylinder eccentrically placed in a square box and on the sedimentation of a cold circular particle in a vertical channel to the data in the literature. The code for the case of freely varying temperature on the boundaries of freely moving particles is applied to analyze the motion of a catalyst particle in a box and in particular the heat conductivities of nanofluids and sheared non-colloidal suspensions, respectively. Our preliminary computational results support the argument that the micro-heat-convection in the fluids is primarily responsible for the unusually high heat conductivity of nanofluids. It is shown that the Peclet number plays a negative role in the diffusion-related heat conductivity of a sheared non-colloidal suspension, whereas the Reynolds number does the

  4. Flow and Convective Heat Transfer of Cylinder Misaligned from Aerodynamic Axis of Cyclone Flow

    Directory of Open Access Journals (Sweden)

    I. L. Leukhin

    2008-01-01

    Full Text Available The paper provides and analyzes results of experimental investigations on physical specific features of hydrodynamics and convective heat transfer of a cyclone flow with a group of round cylinders located symmetrically relative to its aerodynamic axis, calculative equations for average and local heat transfer factors at characteristic sections of cylinder surface.

  5. Heat transfer in thin, compact heat exchangers with circular, rectangular, or pin-fin flow passages

    Science.gov (United States)

    Olson, D. A.

    1992-01-01

    Heat transfer and pressure drop have been measured of three thin, compact heat exchangers in helium gas at 3.5 MPa and higher, with Reynolds numbers of 450 to 36,000. The flow geometries for the three heat exchanger specimens were: circular tube, rectangular channel, and staggered pin fin with tapered pins. The specimens were heated radiatively at heat fluxes up to 77 W/sq cm. Correlations were developed for the isothermal friction factor as a function of Reynolds number, and for the Nusselt number as a function of Reynolds number and the ratio of wall temperature to fluid temperature. The specimen with the pin fin internal geometry had significantly better heat transfer than the other specimens, but it also had higher pressure drop. For certain conditions of helium flow and heating, the temperature more than doubled from the inlet to the outlet of the specimens, producing large changes in gas velocity, density, viscosity, and thermal conductivity. These changes in properties did not affect the correlations for friction factor and Nusselt number in turbulent flow.

  6. Laminar hydromagnetic flows in an inclined heated layer

    Directory of Open Access Journals (Sweden)

    Paolo Falsaperla

    2016-05-01

    Full Text Available In this paper we investigate, analytically, stationary laminar flow solutions of an inclined layer filled with a hydromagnetic fluid heated from below and subject to the gravity field. In particular we describe in a systematic way the many basic solutions associated to the system. This extensive work is the basis to linear instability and nonlinear stability analysis of such motions.

  7. Heat Flow for the Minimal Surface with Plateau Boundary Condition

    Institute of Scientific and Technical Information of China (English)

    Kung Ching CHANG; Jia Quan LIU

    2003-01-01

    The heat flow for the minimal surface under Plateau boundary condition is defined to be aparabolic variational inequality, and then the existence, uniqueness, regularity, continuous dependenceon the initial data and the asymptotics are studied. It is applied as a deformation of the level sets inthe critical point theory.

  8. On the Curvature and Heat Flow on Hamiltonian Systems

    Directory of Open Access Journals (Sweden)

    Ohta Shin-ichi

    2014-01-01

    Full Text Available We develop the differential geometric and geometric analytic studies of Hamiltonian systems. Key ingredients are the curvature operator, the weighted Laplacian, and the associated Riccati equation.We prove appropriate generalizations of the Bochner-Weitzenböck formula and Laplacian comparison theorem, and study the heat flow.

  9. Fluid Flow and Heat Transfer over a Permeable Stretching Cylinder

    Directory of Open Access Journals (Sweden)

    K Vajravelu

    2014-01-01

    Full Text Available In this paper, we analyze the effects of thermo-physical properties on the axisymmetric flow of a viscous fluid induced by a stretching cylinder in the presence of internal heat generation/absorption. It is assumed that the cylinder is stretched in the axial direction with a linear velocity and the surface temperature of the cylinder is subjected to vary linearly. Here, the temperature dependent thermo-physical properties namely, the fluid viscosity and the fluid thermal conductivity are respectively assumed to vary as an inverse function of the temperature and a linear function of the temperature. The governing system of partial differential equations is converted into a system of coupled non-linear ordinary differential equations with variable coefficients. The resulting system is solved numerically using a second order finite difference scheme known as the Keller-box method. The governing equations of the problem show that the flow and heat transfer characteristics depend on six parameters, namely the curvature parameter, fluid viscosity parameter, injection/suction parameter, variable thermal conductivity parameter, heat source/sink parameter and the Prandtl number. The numerical values obtained for the velocity, temperature, skin friction, and the Nusselt number are presented through graphs and tables for several sets of values of the pertinent parameters. The results obtained for the flow and heat transfer characteristics reveal many interesting behaviors that warrant further study on the axisymmetric flow phenomena. Comparisons with the available results in the literature are presented as special cases.

  10. Geothermal heat exchanger with coaxial flow of fluids

    Directory of Open Access Journals (Sweden)

    Pejić Dragan M.

    2005-01-01

    Full Text Available The paper deals with a heat exchanger with coaxial flow. Two coaxial pipes of the secondary part were placed directly into a geothermal boring in such a way that geothermal water flows around the outer pipe. Starting from the energy balance of the exchanger formed in this way and the assumption of a study-state operating regime, a mathematical model was formulated. On the basis of the model, the secondary circle output temperature was determined as a function of the exchanger geometry, the coefficient of heat passing through the heat exchange areas, the average mass isobaric specific heats of fluid and mass flows. The input temperature of the exchanger secondary circle and the temperature of the geothermal water at the exit of the boring were taken as known values. Also, an analysis of changes in certain factors influencing the secondary water temperature was carried out. The parameters (flow temperature of the deep boring B-4 in Sijarinska Spa, Serbia were used. The theoretical results obtained indicate the great potential of this boring and the possible application of such an exchanger.

  11. Single phase channel flow forced convection heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Hartnett, J.P.

    1999-04-01

    A review of the current knowledge of single phase forced convection channel flow of liquids (Pr > 5) is presented. Two basic channel geometries are considered, the circular tube and the rectangular duct. Both laminar flow and turbulent flow are covered. The review begins with a brief overview of the heat transfer behavior of Newtonian fluids followed by a more detailed presentation of the behavior of purely viscous and viscoelastic Non-Newtonian fluids. Recent developments dealing with aqueous solutions of high molecular weight polymers and aqueous solutions of surfactants are discussed. The review concludes by citing a number of challenging research opportunities.

  12. A review of the heat flow data of NE Morocco

    Science.gov (United States)

    Chiozzi, Paolo; Barkaoui, Alae-Eddine; Rimi, Abdelkrim; Verdoya, Massimo; Zarhloule, Yassine

    2016-04-01

    The Atlas chain is characterised by a SW-NE trending volcanic belt roughly extending from the Atlantic to the Mediterranean Sea and showing activity that spans in age mainly from Middle Miocene to Quaternary (14.6-0.3 Ma). The geochemical features of volcanism are mostly intraplate and alkaline with the exception of the northeastern termination of the belt where calc-alkaline series crop out. Lithospheric thermal and density models so far proposed, constrained by heat flow, gravity anomalies, geoid, and topography data, show that the Atlas chain is not supported isostatically by a thickened crust and a thin, hot and low-density lithosphere explains the high topography. One of the possible explanations for lithospheric mantle thinning, possibly in relation with the observed alkaline volcanism, is thermal erosion produced by either small-scale convection or activation of a small mantle plume, forming part of a hot and deep mantle reservoir system extending from the Canary Islands. This paper focuses on the several geothermal data available in the northeastern sector of the volcanic belt. The occurrence of an extensive, often artesian, carbonatic reservoir hosting moderately hot groundwater might boost the temperature gradient in the overlying impermeable cover, and consequently mask the deep thermal regime. We therefore revised the available dataset and investigated the contribution of advection. Temperature data available from water and oil wells were reprocessed and analysed in combination with thermal conductivity measurements on a wide set of lithotypes. Data were filtered according to rigid selection criteria, and, in the deeper boreholes, the heat flow was inferred by taking into account the porosity variation with depth and the temperature effect on the matrix and pore-filling fluid conductivity. Moreover, the possible effect of advection was evaluated with simple analytical models which envisage the carbonatic layers as confined aquifers heated by the

  13. Heat Transfer Coefficient Measurement for Downward Facing Flow Boiling Heat Transfer

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jun Yeong; Jeong, Yong Hoon [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    To evaluate heat transfer capability of the ERVC, estimating heat transfer coefficient (HTC) is important. In this study, the HTCs were experimentally measured, and large break loss of coolant accident (LLOCA) was used as basic accident. At the lower head outer wall, heat transfer phenomenon was downward facing flow boiling heat transfer. Because, natural circulation occurred. Hence, to simulate the flow boiling, water loop was designed. The reactor vessel lower head was simulated as 2-D slice main heater. To simulate the heat transfer characteristics of material and geometry, the main heater was made of SA508 consisting the reactor vessel, and its radius curvature was 2.5 m. The main heater outer surface (facing to air) temperature was measured by infrared (IR) camera, and the inner surface (facing to working fluid) temperature was calculated by solving conduction equation of main heater. The main heater heat flux was under CHF value of previous research. The results of 60 .deg. and 90 .deg. were used as representative angular location data. LLOCA was used as basic accident. Through this experiment, the HTC data was produced for SA508 heat transfer surface material and 2.5 m of radius curvature. The HTCs result shown different trend at each angular location. The HTCs commonly increased with heat flux increment, but the trends were different for angular location.

  14. THE HEAT AND FLUID FLOW ANALYSIS FOR WATER HEATER

    Directory of Open Access Journals (Sweden)

    Chien-Nan Lin

    2011-01-01

    Full Text Available In this paper, the heat transfer and fluid flow are studied for the water heater of RV cars, in which the hot water is heated by the combustion energy of liquefied petroleum gases. Three types of combustion tubes are performed in this investigation, which are circular tube, elliptic tube and elliptic tube with screwed wire inserted. The heat transfer performances of numerical simulation results are compared with those of the experimental works; they are in good trend agreement. The elliptic combustion tube performs better than the circular one, which indicates the average 7% energy saving for the elliptic combustion tube and 12% energy saving for the elliptic combustion tube with screwed wire under static heating.

  15. EXPERIMENTAL STUDY OF ENHANCED HEAT TRANSFER BY FLOW-INDUCED VIBRATION OF ELASTIC TUBE BUNDLES

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A new concept of heat transfer enhancement by flow-induced vibration was put forward, and a novel heat transfer element called elastic tube bundles was designed. The experimental investigation was performed on its characteristics of flow-induced virbration in out-tube or in-tube flow. Under the conditions of fixed heat flux and steam-water heat transfer, the regularity of heat transfer enhancement by flow-induced vibration was examined.

  16. Flow film boiling heat transfer for subcooled liquids flowing upward perpendicular to single horizontal cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Q.S. [Kobe Univ. of Mercantile Marine, Dept. of Nuclear Engineering (Japan); Shiotsu, M. [Kyoto Univ., Dept. of Energy Sci. and Tech. (Japan); Sakurai, A. [Kyoto Univ. (Japan)

    2001-07-01

    The knowledge of flow film boiling heat transfer on a horizontal cylinder in various liquids flowing upward perpendicular to the cylinder is important as the database for the safety evaluation of the accidents such as rapid power burst and pressure reduction in the nuclear power plants. Flow film boiling heat transfer from single horizontal cylinders in water and Freon-113 flowing upward perpendicular to the cylinder under subcooled conditions was measured under wide experimental conditions. The flow velocities ranged from 0 to 1 m/s, the system pressures ranged from 100 to 500 kPa, and the surface superheats were raised up to 800 K for water and 400 K for Freon-113, respectively. Platinum horizontal cylinders with diameters ranging from 0.7 to 5 mm were used as the test heaters. The test heater was heated by direct electric current. The experimental data of film boiling heat transfer coefficients show that they increase with the increase of flow velocity, liquid subcooling, system pressure and with the decrease of cylinder diameter. Based on the experimental data, a correlation for subcooled flow film boiling heat transfer including the effects of liquid subcooling and radiation was presented, which can describe the experimental data obtained within 20% for the flow velocities below 0.7 m/s, and within -30% to +20% for the higher flow velocities. The correlation also predicted well the data by Shigechi (1983), Motte and Bromley (1957), and Sankaran and Witte (1990) obtained for the larger diameter cylinders and higher flow velocities in various liquids at the pressures of near atmospheric. The Shigechi's data were in the range from about -20% to +15%, the data of Motte and Bromley were about 30%,and the data of Sankaran and Witte were within +20 % of the curves given by the corresponding predicted values. (authors)

  17. Investigation into flow boiling heat transfer in a minichannel with enhanced heating surface

    Directory of Open Access Journals (Sweden)

    Piasecka Magdalena

    2012-04-01

    Full Text Available The paper presents results of flow boiling in a minichannel of 1.0 mm depth. The heating element for the working fluid (FC-72 that flows along the minichannel is a single-sided enhanced alloy foil made from Haynes-230. Microrecesses were formed on the selected area of the heating foil by laser technology. The observations of the flow structure were carried out through a piece of glass. Simultaneously, owing to the liquid crystal layer placed on the opposite side of the enhanced foil surface, it was possible to measure temperature distribution on the heating wall through another piece of glass. The experimental research has been focused on the transition from single phase forced convection to nucleate boiling, i.e. the zone of boiling incipience and further development of boiling. The objective of the paper is determining of the void fraction for some cross-sections of selected images for increasing heat fluxes supplied to the heating surface. The flow structure photos were processed in Corel graphics software and binarized. The analysis of phase volumes was developed in Techystem Globe software.

  18. Heat transfer enhancement in cross-flow heat exchangers using oval tubes and multiple delta winglets

    Energy Technology Data Exchange (ETDEWEB)

    Tiwari, S.; Maurya, D.; Biswas, G.; Eswaran, V. [Indian Institute of Technology, Kanpur (India). Dept. of Mechanical Engineering

    2003-07-01

    A three-dimensional study of laminar flow and heat transfer in a channel with built-in oval tube and delta winglets is carried out through the solution of the complete Navier-Stokes and energy equations using a body-fitted grid and a finite-volume method. The geometrical configuration represents an element of a gas-liquid fin-tube cross-flow heat exchanger. The size of such heat exchangers can be reduced through enhancement of transport coefficients on the air (gas) side, which are usually small compared to the liquid side. In a suggested strategy, oval tubes are used in place of circular tubes, and delta-winglet type vortex generators in various configuration's are mounted on the fin-surface. An evaluation of the strategy is attempted in this investigation. The investigation is carried out for different angles of attack of the winglets to the incoming flow for the case of two winglet pairs. The variation of axial location of the winglets is also considered for one pair of winglets mounted in common-flow-down configuration. The structures of the velocity field and the heat transfer characteristics have been presented. The results indicate that vortex generators in conjunction with the oval tube show definite promise for the improvement of fin-tube heat exchangers. (author)

  19. Influence of Ohmic Heating on Advection-Dominated Accretion Flows

    CERN Document Server

    Bisnovatyi-Kogan, G S

    1997-01-01

    Advection-dominated, high-temperature, quasi-spherical accretion flow onto a compact object of mass M, recently considered by a number of authors, assume that the dissipation of turbulent energy of the flow heats the ions and that a constant fraction f of the dissipated energy is advected inward. It is suggested that the efficiency of conversion of accretion energy to radiation can be very much smaller than unity. However, it is likely that the flows have an equipartition magnetic field with the result that dissipation of magnetic energy at a rate comparable to that for the turbulence must occur by Ohmic heating. We argue that this heating occurs as a result of plasma instabilities and that the relevant instabilities are current driven in response to the strong electric fields parallel to the magnetic field. We argue further that these instabilities heat predominantly the electrons. We analyze a model for the radial dependence of the ion and electron temperatures of a general, possibly quasi-spherical accreti...

  20. Melt Flow and Heat Transfer in Laser Drilling

    CERN Document Server

    Yang, Youqing; Zhang, Yuwen

    2016-01-01

    During the laser drilling process the recoil pressure drives melt flow and affects the heat transfer and material removal rate. To get a more realistic picture of the melt flow, a series of differential equations are formulated here that govern the process from pre-heating to melting and evaporation. In particular, the Navier-Stokes equation governing the melt flow is solved with the use of the boundary layer theory and integral methods. Heat conduction in solid is investigated by using the classical method with the corrections that reflect the change in boundary condition from the constant heat flux to Stefan condition. The dependence of saturation temperature on the vapor pressure is taken into account by using the Clausius-Clapeyron equation. Both constantly rising radial velocity profiles and rising-fall velocity profiles are considered. The proposed approach is compared with existing ones. In spite of the assumed varying velocity profiles, the proposed model predicts that the drilling hole profiles are v...

  1. Anomalous heat flow belt along the continental margin of Brazil

    Science.gov (United States)

    Hamza, Valiya M.; Vieira, Fabio P.; Silva, Raquel T. A.

    2017-06-01

    A comprehensive analysis of thermal gradient and heat flow data was carried out for sedimentary basins situated in the continental margin of Brazil (CMB). The results point to the existence of a narrow belt within CMB, where temperature gradients are higher than 30 °C/km and the heat flow is in excess of 70 mW/m2. This anomalous geothermal belt is confined between zones of relatively low to normal heat flow in the adjacent continental and oceanic regions. The width of the belt is somewhat variable, but most of it falls within the range of 100-300 km. The spatial extent is relatively large in the southern (in the basins of Pelotas, Santos and Campos) and northern (in the basins of Potiguar and Ceará) parts, when compared with those in the central parts (in the basins of South Bahia, Sergipe and Alagoas). The characteristics of heat flow anomalies appear to be compatible with those produced by thermal sources at depths in the lower crust. Hence, magma emplacement at the transition zone between lower crust and upper mantle is considered the likely mechanism producing such anomalies. Seismicity within the belt is relatively weak, with focal depths less than 10 km for most of the events. Such observations imply that "tectonic bonding" between continental and oceanic segments, at the transition zone of CMB, is relatively weak. Hence, it is proposed that passive margins like CMB be considered as constituting a type of plate boundary that is aseismic at sub-crustal levels, but allows for escape of significant amounts of earth's internal heat at shallow depths.

  2. Predicting Turbulent Convective Heat Transfer in Fully Developed Duct Flows

    Science.gov (United States)

    Rokni, Masoud; Gatski, Thomas B.

    2001-01-01

    The performance of an explicit algebraic stress model (EASM) is assessed in predicting the turbulent flow and forced heat transfer in both straight and wavy ducts, with rectangular, trapezoidal and triangular cross-sections, under fully developed conditions. A comparison of secondary flow patterns. including velocity vectors and velocity and temperature contours, are shown in order to study the effect of waviness on flow dynamics, and comparisons between the hydraulic parameters. Fanning friction factor and Nusselt number, are also presented. In all cases. isothermal conditions are imposed on the duct walls, and the turbulent heat fluxes are modeled using gradient-diffusion type models. The formulation is valid for Reynolds numbers up to 10(exp 5) and this minimizes the need for wall functions that have been used with mixed success in previous studies of complex duct flows. In addition, the present formulation imposes minimal demand on the number of grid points without any convergence or stability problems. Criteria in terms of heat transfer and friction factor needed to choose the optimal wavy duct cross-section for industrial applications among the ones considered are discussed.

  3. Preferential flow paths and heat pipes: Results from laboratory experiments on heat-driven flow in natural and artificial rock fractures

    Energy Technology Data Exchange (ETDEWEB)

    Kneafsey, T.J.; Pruess, K. [Lawrence Berkeley National Lab., CA (United States). Earth Sciences Div.

    1997-06-01

    Water flow in fractures under the conditions of partial saturation and thermal drive may lead to fast flow along preferential localized pathways and heat pipe conditions. Water flowing in fast pathways may ultimately contact waste packages at Yucca Mountain and transport radionuclides to the accessible environment. Sixteen experiments were conducted to visualize liquid flow in glass fracture models, a transparent epoxy fracture replica, and a rock/replica fracture assembly. Spatially resolved thermal monitoring was performed in seven of these experiments to evaluate heat-pipe formation. Depending on the fracture apertures and flow conditions, various flow regimes were observed including continuous rivulet flow for high flow rates, intermittent rivulet flow and drop flow for intermediate flow rates, and film flow for low flow rates and wide apertures. These flow regimes were present in both fracture models and in the replica of a natural fracture. Heat-pipe conditions indicated by low thermal gradients were observed in five experiments. Conditions conducive to heat-pipe formation include an evaporation zone, condensation zone, adequate space for vapor and liquid to travel, and appropriate fluid driving forces. In one of the two experiments where heat pipe conditions were not observed, adequate space for liquid-vapor counterflow was not provided. Heat pipe conditions were not established in the other, because liquid flow was inadequate to compensate for imbibition and the quantity of heat contained within the rock.

  4. Measuring Heat Flow on the Moon and Mars- The Heat Flow and Physical Properties Package HP-cubed

    Science.gov (United States)

    Spohn, T.; Grott, M.; Ho, T.; van Zoest, T.; Kargl, G.; Smrekar, S. E.; Hudson, T. L.

    2010-12-01

    With only two successful heat flow measurements performed on the surface of the Moon to date, the thermal state of the Moon remains poorly constrained. Furthermore, measurements were taken close to the boundary of the Procellarum KREEP terraine, and the obtained values may not be representative for the bulk of the planet. For Mars, no heat flow measurement is yet available. Here we will present the Heat Flow and Physical Properties Package HP-cubed a self-penetrating, robotic heat flow probe. The instrument consists of electrical and temperature sensors that will be emplaced into the lunar subsurface by means of an electro-mechanical hammering mechanism. The instruement is foreseen to penetrate 3-5 m into the planet’s soil and will perform depth resolved measurements, from which the surface planetary heat flow can be directly deduced. The instrument has been pre-developed in two ESA funded precursor studies and has been further developed in the framework of ESA’s ExoMars mission. The current readiness level of the instrument is TRL 5.62 (ESA PDR Apr. 2009) which has been achieved with several Breadboards developed and tested between 2004 and 2009. As no drilling is required to achieve soil penetration, HP-cubed is a relatively lightweight heat flow probe, weighting less than 1800 g. It has been further studied as parts of the discovery proposals Lunette and GEMS and for the proposed Japanese lunar mission SELENE 2 The instrument consists of an electro-mechanic mole, a pay-load compartment, and a tether equipped with temperature sensors. The latter can be actively heated for thermal conductivity measurements. A tiltmeter and acceleraometer will help to track the path of the mole. The payload compartment has room for sensors such as a permittivity probe, a bore-hole camera, and/or a masspectrometer. Following deployment of the instrument, instrument operations will be split into two phases: During the penetration phase soil intrusion is achieved by means of the

  5. Heat Transfer Enhancement in Turbulent Flows by Blocked Surfaces

    Directory of Open Access Journals (Sweden)

    Onur YEMENİCİ

    2013-04-01

    Full Text Available In this study, the heat transfer analyses over flat and blocked surfaces were carried out in turbulent flow under the influence of the block height. A constant-temperature hot wire anemometer was used to the velocity and turbulent intensity measurements, while temperature values were measured by copper-constantan thermocouples. The average Stanton numbers for block heights of 15 and 25 mm were higher than those of flat surface by %38 and %84, respectively. The results showed that the presence of the blocks increased the heat transfer and the enhancement rose with block heights

  6. Multiple nonequilibrium steady states for one-dimensional heat flow.

    Science.gov (United States)

    Zhang, F; Isbister, D J; Evans, D J

    2001-08-01

    A nonequilibrium molecular dynamics model of heat flow in one-dimensional lattices is shown to have multiple steady states for any fixed heat field strength f(e) ranging from zero to a certain positive value. We demonstrate that, depending on the initial conditions, there are at least two possibilities for the system's evolution: (i) formation of a stable traveling wave (soliton), and (ii) chaotic motion throughout the entire simulation. The percentage of the soliton-generating trajectories is zero for small field strength f(e), but increases sharply to unity over a critical region of the parameter f(e).

  7. Heat transfer and fluid flow in nuclear systems

    CERN Document Server

    Fenech, Henri

    1982-01-01

    Heat Transfer and Fluid in Flow Nuclear Systems discusses topics that bridge the gap between the fundamental principles and the designed practices. The book is comprised of six chapters that cover analysis of the predicting thermal-hydraulics performance of large nuclear reactors and associated heat-exchangers or steam generators of various nuclear systems. Chapter 1 tackles the general considerations on thermal design and performance requirements of nuclear reactor cores. The second chapter deals with pressurized subcooled light water systems, and the third chapter covers boiling water reacto

  8. Comparative study of heat transfer and pressure drop during flow boiling and flow condensation in minichannels

    Directory of Open Access Journals (Sweden)

    Mikielewicz Dariusz

    2014-09-01

    Full Text Available In the paper a method developed earlier by authors is applied to calculations of pressure drop and heat transfer coefficient for flow boiling and also flow condensation for some recent data collected from literature for such fluids as R404a, R600a, R290, R32,R134a, R1234yf and other. The modification of interface shear stresses between flow boiling and flow condensation in annular flow structure are considered through incorporation of the so called blowing parameter. The shear stress between vapor phase and liquid phase is generally a function of nonisothermal effects. The mechanism of modification of shear stresses at the vapor-liquid interface has been presented in detail. In case of annular flow it contributes to thickening and thinning of the liquid film, which corresponds to condensation and boiling respectively. There is also a different influence of heat flux on the modification of shear stress in the bubbly flow structure, where it affects bubble nucleation. In that case the effect of applied heat flux is considered. As a result a modified form of the two-phase flow multiplier is obtained, in which the nonadiabatic effect is clearly pronounced.

  9. New and classical applications of heat flow studies

    Science.gov (United States)

    Clauser, C.

    2005-12-01

    This special issue of Journal of Geophysics and Engineering is dedicated to a collection of papers which resulted from an international workshop held in Aachen, Germany, on 4-7 October 2004, called 'New and Classical Applications of Heat Flow Studies'. This was the third in a series of topical geothermal workshops arranged by the Geothermal Working Group of the German Geophysical Society (DGG) and was organized by the Institute of Applied Geophysics at RWTH Aachen University under the auspices of the International Heat Flow Commission of the International Association of Seismology and Physics (IASPEI). The meeting was attended by some 60 scientists from 14 countries and three continents. Financial assistance, granted by DGG and IASPEI, allowed us to provide partial support for a total of eight students, young scientists and eminent researchers from eastern Europe and overseas. The convenors of the meeting were Christoph Clauser (Aachen), Thomas Kohl (Zürich) and Makoto Taniguchi (Kyoto). The main local organizers were Volker Rath (scientific programme) and Ute Kreutz (accommodation and financial affairs). The topics addressed in more than 50 oral and poster presentations indicated that today intriguing new applications of heat flow studies have emerged, complementing the classical topics of heat flow mapping and the tectonic implications of heat flow. In classical applications, for instance, thermal signatures of water flow or downward diffusion of variations in the Earth's mean temperature are considered as noise which needs to be corrected prior to further use of the data. In contrast, in several new applications it is exactly the information contained in these signatures which has been extracted and interpreted. For instance, over the past two decades, work on the most prominent of these new applications has been devoted to inverting the variation of the Earth's past mean ground surface temperature (GST). As of today, GST provided by the geothermal method has

  10. Evaluation of heat and water flow in porosity permeable horizons

    Science.gov (United States)

    Pasquale, Vincenzo; Verdoya, Massimo; Chiozzi, Paolo

    2010-05-01

    Several strategies have been developed to explore the circulation of geofluids, which can yield heat transport over large spatial scales. Groundwater flow from recharge areas, where precipitation seeps downwards beneath the ground surface and reaches the saturated zone, to discharge areas, where subsurface water is discharged to streams, lakes, ponds or swamps, forms an additional mechanism of heat transfer to pure conduction, which is generally assumed for the underground thermal regime. In this paper we discuss and apply two different analytical models of heat and water flow, both valid for steady-state thermal conditions and for uniform, isotropic, homogeneous, and saturated porous media. By combining conductive and groundwater advective heat transfer, a first model assumes heat and water flow in vertical direction and neglects thermal gradient along the horizontal. The thermal field is influenced only by the flow of water parallel to the thermal gradient, whereas perpendicular water flow if any has no effect. Because most layers are sloping and because surface topographic relief usually exists across the aquifer, usually isotherms are not horizontal. Hence, we applied a second model for heat and water flow, neither purely horizontal nor purely vertical. In the governing equation of heat conduction-advection we take account of the horizontal flow of heat and water. The flow rate is assumed to be constant and sufficient small that thermal equilibrium is maintained between the water and the rock matrix. Examples of application are given for a set of boreholes drilled for geothermal exploration. Hydrothermal parameters (vertical and horizontal components of the Darcy velocity and the Péclet number) are determined by matching temperature and thermal gradient versus depth data with the two models. Thermal information is completed by a set of thermal conductivity measurements carried out on core samples recovered during drillings. The analysed underground

  11. Numerical simulations of heat transfer in plane channel flow

    CERN Document Server

    Gharbi, Najla El; Benzaoui, Ahmed

    2010-01-01

    Reynolds-averaged Navier-Stokes (RANS) turbulence models (such as k-{\\epsilon} models) are still widely used for engineering applications because of their relatively simplicity and robustness. In fully developed plane channel flow (i.e. the flow between two infinitely large plates), even if available models and near-wall treatments provide adequate mean flow velocities, they fail to predict suitable turbulent kinetic energy "TKE" profiles near walls. TKE is involved in determination of eddy viscosity/diffusivity and could therefore provide inaccurate concentrations and temperatures. In order to improve TKE a User Define Function "UDF" based on an analytical profile for TKE was developed and implemented in Fluent. Mean streamwise velocity and turbulent kinetic energy "TKE" profiles were compared to DNS data for friction Reynolds number $Re_{\\tau}$ = 150. Simulation results for TKE show accurate profiles. Simulation results for horizontal heated channel flows obtained with Fluent are presented. Numerical result...

  12. Heat Transfer Characteristics of Slush Nitrogen in Turbulent Pipe Flows

    Science.gov (United States)

    Ohira, K.; Ishimoto, J.; Nozawa, M.; Kura, T.; Takahashi, N.

    2008-03-01

    Slush fluids, such as slush hydrogen and slush nitrogen, are two-phase (solid-liquid) single-component cryogenic fluids containing solid particles in a liquid, and consequently their density and refrigerant capacity are greater than for liquid state fluid alone. This paper reports on the experimental results of the forced convection heat transfer characteristics of slush nitrogen flowing in a pipe. Heat was supplied to slush nitrogen by a heater wound around the copper pipe wall. The local heat transfer coefficient was measured in conjunction with changes in the velocity and the solid fraction. The differences in heat transfer characteristics between two-phase slush and single phase liquid nitrogen were obtained, and the decrease in heat transfer to slush nitrogen caused by the previously observed pressure drop reduction was confirmed by this study. Furthermore, for the purpose of establishing the thermal design criteria for slush nitrogen in the case of pressure drop reduction, the heat transfer correlation between the experimental results and the Sieder-Tate Equation was obtained.

  13. Study of Polyurethane Foaming Dynamics Using a Heat Flow Meter

    Science.gov (United States)

    Koniorczyk, P.; Trzyna, M.; Zmywaczyk, J.; Zygmunt, B.; Preiskorn, M.

    2017-05-01

    This work presents the results of the study concerning the effects of fillers addition on the heat flux density \\dot{q}( t ) of foaming of polyurethane-polystyrene porous composite (PSUR) and describes the dynamics of this process during the first 600 s. This foaming process resulted in obtaining porous materials that were based on HFC 365/225 blown rigid polyurethane foam (PUR) matrix, which contained thermoplastic expandable polystyrene (EPS) beads as the filler. In PSUR composites, the EPS beads were expanded after being heated to a temperature above the glass transition temperature of EPS and vaporing gas incorporated inside, by using the heat of exothermic reaction of polyol with isocyanate. From the start (t=0) to the end of the PSUR composite foaming process (t=tk), \\dot{q}( t ) was measured with the use of the heat flow meter. For the purpose of the study two PUR systems were selected: one with high and one with low heat density of foaming process q. EPS beads were selected from the same manufacturer with large and small diameter. The mass fraction of EPS in PSUR foam varied during the measurements. Additionally, a study of volume fractions of expanded EPS phase in PSUR foams as a function of mass fractions of EPS was conducted. In order to verify effects of the EPS addition on the heat flux density during PSUR foaming process, the thermal conductivity measurements were taken.

  14. Slip Flow in Elliptic Microducts with Constant Heat Flux

    Directory of Open Access Journals (Sweden)

    Marco Spiga

    2012-01-01

    Full Text Available This paper outlines a numerical model for determining the dynamic and thermal performances of a rarefied fluid flowing in a microduct with elliptical cross-section. A slip flow is considered, in laminar steady state condition, in fully developed forced convection, with Knudsen number in the range 0.001−0.1, in H1 boundary conditions. The velocity and temperature distributions are determined in the elliptic cross-section, for different values of both aspect ratio γ and Knudsen number, resorting to the Comsol Multiphysics software, to solve the momentum and energy equations. The friction factors (or Poiseuille numbers and the convective heat transfer coefficients (or Nusselt numbers are calculated and presented in graphs and tables. The numerical solution is validated resorting to data available in literature for continuum flow in elliptic cross-sections (Kn = 0 and for slip flow in circular ducts (γ=1. A further benchmark is carried out for the velocity profile for slip flow in ellipticalcross-sections, thanks to a recent analytical solution obtained using elliptic cylinder coordinates and the separation of variables method. The Poiseuille and Nusselt numbers for elliptic cross-sections are discussed. The results may be used to predict pressure drop and heat transfer performance in metallic microducts with elliptic cross-section, produced by microfabrication for microelectromechanical systems (MEMS.

  15. A laser-induced heat flux technique for convective heat transfer measurements in high speed flows

    Science.gov (United States)

    Porro, A. R.; Keith, T. G., Jr.; Hingst, W. R.

    1991-01-01

    A technique is developed to measure the local convective heat transfer coefficient on a model surface in a supersonic flow field. The technique uses a laser to apply a discrete local heat flux at the model test surface, and an infrared camera system determines the local temperature distribution due to the heating. From this temperature distribution and an analysis of the heating process, a local convective heat transfer coefficient is determined. The technique was used to measure the local surface convective heat transfer coefficient distribution on a flat plate at nominal Mach numbers of 2.5, 3.0, 3.5, and 4.0. The flat plate boundary layer initially was laminar and became transitional in the measurement region. The experimentally determined convective heat transfer coefficients were generally higher than the theoretical predictions for flat plate laminar boundary layers. However, the results indicate that this nonintrusive optical measurement technique has the potential to measure surface convective heat transfer coefficients in high-speed flowfields.

  16. Measuring fluid flow and heat output in seafloor hydrothermal environments

    Science.gov (United States)

    Germanovich, Leonid N.; Hurt, Robert S.; Smith, Joshua E.; Genc, Gence; Lowell, Robert P.

    2015-12-01

    We review techniques for measuring fluid flow and advective heat output from seafloor hydrothermal systems and describe new anemometer and turbine flowmeter devices we have designed, built, calibrated, and tested. These devices allow measuring fluid velocity at high- and low-temperature focused and diffuse discharge sites at oceanic spreading centers. The devices perform at ocean floor depths and black smoker temperatures and can be used to measure flow rates ranging over 2 orders of magnitude. Flow velocity is determined from the rotation rate of the rotor blades or paddle assembly. These devices have an open bearing design that eliminates clogging by particles or chemical precipitates as the fluid passes by the rotors. The devices are compact and lightweight enough for deployment from either an occupied or remotely operated submersible. The measured flow rates can be used in conjunction with vent temperature or geochemical measurements to obtain heat outputs or geochemical fluxes from both vent chimneys and diffuse flow regions. The devices have been tested on 30 Alvin dives on the Juan de Fuca Ridge and 3 Jason dives on the East Pacific Rise (EPR). We measured an anomalously low entrainment coefficient (0.064) and report 104 new measurements over a wide range of discharge temperatures (5°-363°C), velocities (2-199 cm/s), and depths (1517-2511 m). These include the first advective heat output measurements at the High Rise vent field and the first direct fluid flow measurement at Middle Valley. Our data suggest that black smoker heat output at the Main Endeavour vent field may have declined since 1994 and that after the 2005-2006 eruption, the high-temperature advective flow at the EPR 9°50'N field may have become more channelized, predominately discharging through the Bio 9 structure. We also report 16 measurements on 10 Alvin dives and 2 Jason dives with flow meters that predate devices described in this work and were used in the process of their development

  17. Convective heat transfer enhancement of laminar flow of latent functionally thermal fluid in a circular tube with constant heat flux: internal heat source model and its application

    Institute of Scientific and Technical Information of China (English)

    张寅平; 胡先旭; 郝磬; 王馨

    2003-01-01

    This paper analyzes the convective heat transfer enhancement mechanism of latent heat functionally thermal fluid. By using the proposed internal heat source model, the influence of each factor affecting the heat transfer enhancement of laminar flow in a circular tube with constant heat flux is analyzed. The main influencing factors and the mechanisms of heat transfer enhancement are clarified, and the influences of the main factors on the heat transfer enhancement are quantitatively analyzed. A modified Nusselt number for internal flow is introduced to describe more effectively the degree of heat transfer enhancement for latent functionally thermal fluid.

  18. OPTIMISATION OF MANTLE TANKS FOR LOW FLOW SOLAR HEATING SYSTEMS

    DEFF Research Database (Denmark)

    Shah, Louise Jivan; Furbo, Simon

    1996-01-01

    A model, describing the heat transfer coefficients in the mantle of a mantle tank has been developed. The model is validated by means of measurements with varying operational conditions for different designed mantle tanks. The model has been implemented in an existing detailed mathematical...... programme that simulates the thermal behaviour of low flow SDHW systems. The yearly thermal performance of low flow SDHW systems with different designed mantle tanks has been calculated. The influence of the mantle tank design on the thermal performance is investigated by means of the calculations...... with the programme and by means of tests of three SDHW systems with different designed mantle tanks. Based on the investigations design rules for mantle tanks are proposed. The model, describing the heat transfer coefficients in the mantle is approximate. In addition, the measurements have revealed...

  19. Parametric study of fluid flow and heat transfer over louvered fins of air heat pump evaporator

    Science.gov (United States)

    Muszyński, Tomasz; Kozieł, Sławomir Marcin

    2016-09-01

    Two-dimensional numerical investigations of the fluid flow and heat transfer have been carried out for the laminar flow of the louvered fin-plate heat exchanger, designed to work as an air-source heat pump evaporator. The transferred heat and the pressure drop predicted by simulation have been compared with the corresponding experimental data taken from the literature. Two dimensional analyses of the louvered fins with varying geometry have been conducted. Simulations have been performed for different geometries with varying louver pitch, louver angle and different louver blade number. Constant inlet air temperature and varying velocity ranging from 2 to 8 m/s was assumed in the numerical experiments. The air-side performance is evaluated by calculating the temperature and the pressure drop ratio. Efficiency curves are obtained that can be used to select optimum louver geometry for the selected inlet parameters. A total of 363 different cases of various fin geometry for 7 different air velocities were investigated. The maximum heat transfer improvement interpreted in terms of the maximum efficiency has been obtained for the louver angle of 16 ° and the louver pitch of 1.35 mm. The presented results indicate that varying louver geometry might be a convenient way of enhancing performance of heat exchangers.

  20. Heat flow near Kyle Hot Springs, Buena Vista Valley, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Sass, J.H.; Wollenberg, H.A.; di Somma, D.E.; Ziagos, J.P.

    1976-01-01

    It is apparent that heat flow in the area of the electrical geophysical anomaly on the western flank of the East Range is not significantly higher than average for the ''Battle Mountain High,'' and is typical of other values measured in bedrock in the region. Therefore it is unlikely that the anomalous zone is indicative of the presence of a hydrothermal system in that area.

  1. HEAT FLOW FOR YANG-MILLS-HIGGS FIELDS, PART I

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The Yang-Mills-Higgs field generalizes the Yang-Mills field. The authors establish the local existence and uniqueness of the weak solution to the heat flow for the Yang-Mills-Higgs field in a vector bundle over a compact Riemannian 4-manifold, and show that the weak solution is gauge-equivalent to a smooth solution and there are at most finite singularities at the maximum existing time.

  2. Interface oscillation of subcooled flow boiling in locally heated microchannels

    Science.gov (United States)

    Liu, J. T.; Peng, X. F.

    2009-02-01

    An investigation was conducted to understand flow boiling of subcooled de-ionized water in locally heated parallel microchannels. High-speed visualization technology was employed to visually observe the transient phase change process in an individual microchannel. Signal analysis method was employed in studying the interface movement and phase change process. The phase change at locally heated condition was different from those at entirely heated condition where elongated bubble(s) stayed quasi-stable for a long time without venting out. Diversified and intensive interface oscillation was observed occurring on both of the upstream and downstream bubble caps. Evaporation and condensation modes were characterized with distinguished oscillation frequencies. The film-driven oscillations of both evaporating and condensing interfaces generally operated at higher frequencies than the oscillations driven by nucleation or dropwise condensation.

  3. Flow Regimes of Mesoscale Circulations Forced by Inhomogeneous Surface Heating

    CERN Document Server

    Hossain, M Alamgir

    2016-01-01

    Urbanization is one of the extreme process that increases uncertainty in future climate projections. Flow regimes of mesoscale circulations associated with surface heating due to urbanization have been investigated using a wavelet based computational fluid dynamics~(CFD) model. The results of our numerical model have been validated against that of a laboratory model, as well as reference numerical simulations. Characteristics of urban induced circulations have been studied for surface heat flux perturbation ($H_0$) between $28.93$Wm$^{-2}$ and $925.92$Wm$^{-2}$, and the results have been analyzed against available boundary layer measurements under similar physical conditions. Our primary study shows that urban/rural heat flux anomalies introduce strong oscillations in the convective boundary layer (CBL), and transfers a fraction of the turbulent kinetic energy vertically through internal waves. Such results complement previous investigators' hypothesis that temporal oscillations in urban-induced mesoscale cir...

  4. Heat and mass transfer from the mantle: heat flow and He-isotope constraints

    Directory of Open Access Journals (Sweden)

    B. G. Polyak

    2005-06-01

    Full Text Available Terrestrial heat flow density, q, is inversely correlated with the age, t, of tectono-magmatic activity in the Earth's crust (Polyak and Smirnov, 1966; etc.. «Heat flow-age dependence» indicates unknown temporal heat sources in the interior considered a priori as the mantle-derived diapirs. The validity of this hypothesis is demonstrated by studying the helium isotope ratio, 3He/4He = R, in subsurface fluids. This study discovered the positive correlation between the regionally averaged (background estimations of R- and q-values (Polyak et al., 1979a. Such a correlation manifests itself in both pan-regional scales (Norhtern Eurasia and separate regions, e.g., Japan (Sano et al., 1982, Eger Graben (Polyak et al., 1985 Eastern China rifts (Du, 1992, Southern Italy (Italiano et al., 2000, and elsewhere. The R-q relation indicates a coupled heat and mass transfer from the mantle into the crust. From considerations of heat-mass budget this transfer can be provided by the flux consisting of silicate matter rather than He or other volatiles. This conclusion is confirmed by the correlation between 3He/ 4He and 87Sr/86Sr ratios in the products of the volcanic and hydrothermal activity in Italy (Polyak et al., 1979b; Parello et al., 2000 and other places. Migration of any substance through geotemperature field transports thermal energy accumulated within this substance, i.e. represents heat and mass transfer. Therefore, only the coupled analysis of both material and energy aspects of this transfer makes it possible to characterise the process adequately and to decipher an origin of terrestrial heat flow observed in upper parts of the earth crust. An attempt of such kind is made in this paper.

  5. Nonclassical Symmetry Analysis of Heated Two-Dimensional Flow Problems

    Science.gov (United States)

    Naeem, Imran; Naz, Rehana; Khan, Muhammad Danish

    2015-12-01

    This article analyses the nonclassical symmetries and group invariant solution of boundary layer equations for two-dimensional heated flows. First, we derive the nonclassical symmetry determining equations with the aid of the computer package SADE. We solve these equations directly to obtain nonclassical symmetries. We follow standard procedure of computing nonclassical symmetries and consider two different scenarios, ξ1≠0 and ξ1=0, ξ2≠0. Several nonclassical symmetries are reported for both scenarios. Furthermore, numerous group invariant solutions for nonclassical symmetries are derived. The similarity variables associated with each nonclassical symmetry are computed. The similarity variables reduce the system of partial differential equations (PDEs) to a system of ordinary differential equations (ODEs) in terms of similarity variables. The reduced system of ODEs are solved to obtain group invariant solution for governing boundary layer equations for two-dimensional heated flow problems. We successfully formulate a physical problem of heat transfer analysis for fluid flow over a linearly stretching porous plat and, with suitable boundary conditions, we solve this problem.

  6. Numerical investigation of transient heat transfer to hydromagnetic channel flow with radiative heat and convective cooling

    Science.gov (United States)

    Makinde, O. D.; Chinyoka, T.

    2010-12-01

    This present study consists of a numerical investigation of transient heat transfer in channel flow of an electrically conducting variable viscosity Boussinesq fluid in the presence of a magnetic field and thermal radiation. The temperature dependent nature of viscosity is assumed to follow an exponentially model and the system exchanges heat with the ambient following Newton's law of cooling. The governing nonlinear equations of momentum and energy transport are solved numerically using a semi-implicit finite difference method. Solutions are presented in graphical form and given in terms of fluid velocity, fluid temperature, skin friction and heat transfer rate for various parametric values. Our results reveal that combined effect of thermal radiation, magnetic field, viscosity variation and convective cooling have significant impact in controlling the rate of heat transfer in the boundary layer region.

  7. Experimental and Numerical Analysis of Air Flow, Heat Transfer and Thermal Comfort in Buildings with Different Heating Systems

    Science.gov (United States)

    Sabanskis, A.; Virbulis, J.

    2016-04-01

    Monitoring of temperature, humidity and air flow velocity is performed in 5 experimental buildings with the inner size of 3×3×3 m3 located in Riga, Latvia. The buildings are equipped with different heating systems, such as an air-air heat pump, air-water heat pump, capillary heating mat on the ceiling and electric heater. Numerical simulation of air flow and heat transfer by convection, conduction and radiation is carried out using OpenFOAM software and compared with experimental data. Results are analysed regarding the temperature and air flow distribution as well as thermal comfort.

  8. Effect on the load size on the efficiency of microwave heating under stop flow and continuous flow conditions

    NARCIS (Netherlands)

    Patil, N.G.; Rebrov, E.V.; Esveld, D.C.; Eränen, K.; Benaskar, F.; Meuldijk, Jan; Mikkola, J.P.; Hessel, V.; Hulshof, L.A.; Murzin, D.Y.; Schouten, J.C.

    2012-01-01

    A novel heating efficiency analysis of the microwave heated stop-flow (i.e. stagnant
    liquid) and continuous-flow reactors has been presented. The thermal losses to the surrounding
    air by natural convection have been taken into account for heating efficiency calculation of
    the microwave

  9. Effect on the load size on the efficiency of microwave heating under stop flow and continuous flow conditions

    NARCIS (Netherlands)

    Patil, N.G.; Rebrov, E.V.; Esveld, D.C.; Eränen, K.; Benaskar, F.; Meuldijk, Jan; Mikkola, J.P.; Hessel, V.; Hulshof, L.A.; Murzin, D.Y.; Schouten, J.C.

    2012-01-01

    A novel heating efficiency analysis of the microwave heated stop-flow (i.e. stagnant
    liquid) and continuous-flow reactors has been presented. The thermal losses to the surrounding
    air by natural convection have been taken into account for heating efficiency calculation of
    the microwave h

  10. Heat Transfer and Fluid Flow of Nanofluids in Laminar Radial Flow Cooling Systems

    Institute of Scientific and Technical Information of China (English)

    Gilles ROY; Samy Joseph PALM; Cong Tam NGUYEN

    2005-01-01

    Nanofluids are considered as interesting alternatives to conventional coolants. It is well known that traditional fluids have limited heat transfer capabilities when compared to common metals. It is therefore quite conceivable that a small amount of extremely fine metallic particles placed in suspension in traditional fluids will considerably increase their heat transfer performances. A numerical investigation into the heat transfer enhancement capabilities of coolants with suspended metallic nanoparticles inside a radial, laminar flow cooling configuration is presented. Temperature dependant nanofluid properties are evaluated from experimental data available in recent literature. Results indicate that considerable heat transfer increases are possible with the use of relatively small volume fractions of nanoparticles. Generally, however, these are accompanied by considerable increases in wall shear-stress. Results also show that predictions obtained with temperature variable nanofluid properties yield greater heat transfer capabilities and lower wall shear stresses when compared to predictions using constant properties.

  11. Calibrated Heat Flow Model for Determining the Heat Conduction Losses in Laser Cutting of CFRP

    Science.gov (United States)

    Mucha, P.; Weber, R.; Speker, N.; Berger, P.; Sommer, B.; Graf, T.

    Laser machining has great potential regarding automation in fabrication of CFRP (carbon-fiber-reinforced plastics) parts, due to the nearly force and tool-wear free processing at high process speeds. The high vaporization temperatures and the large heat conductivity of the carbon fibers lead to a large heat transport into the sample. This causes the formation of a heat-affected zone and a decrease of the process speed. In the present paper,an analytical heat flow model was adapted in order to understand and investigate the heat conduction losses. Thermal sensors were embedded in samples at different distances from the kerf to fit the calculated to the measured temperatures. Heat conduction losses of up to 30% of the laser power were determined. Furthermore, the energy not absorbed by the sample, the energy for sublimating the composite material in the kerf, the energy for the formation of the HAZ, and the residual heat in the sample are compared in an energy balance.

  12. Computational fluid flow and heat transfer. An engineering tool

    Science.gov (United States)

    Salcudean, Martha

    1991-05-01

    The purpose, method, and potential of computational fluid dynamics (CFD) are discussed. Some examples of CFD and heat transfer applied to engineering problems are described. Simulation of casting in a permanent mold, gallium arsenide crystal growth, and the computation of discharge coefficients in film cooling of turbine blades are briefly described. It is shown the the CFD methods help to improve the understanding of the physics involved. They allow the influence of various parameters on the product or process to be investigated in a relatively inexpensive way. CFD constitutes a predictive tool which allows for product or process optimization. Discretization and solution methods used in the present examples are briefly described. Some limitations of the CFD methods are illustrated. The error introduced by false diffusion is shown for laminar flow around a bluff body. The improvement obtained by a higher order scheme is discussed. Some difficulties related to turbulence modelling are illustrated for the flow and heat transfer around the same bluff body. Turbulent swirling flow between concentric annuli is also discussed. Problems related to the slow convergence rate and major improvements obtained through applying multigrid convergence acceleration methods are shown for two and three dimensional opposing jets penetrating into a main flow.

  13. Effects of thermal property variations on the liquid flow and heat transfer in microchannel heat sinks

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zhigang [Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100080 (China); Graduate School of Chinese Academy of Sciences, Beijing 100080 (China); Huai, Xiulan; Tao, Yujia; Chen, Huanzhuo [Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100080 (China)

    2007-12-15

    Three-dimensional conjugate numerical simulations using the inlet, average and variable thermal properties respectively were performed for the laminar water flow and heat transfer in rectangular microchannels with D{sub h} of 0.333 mm at Re of 101-1775. Both average and variable properties are adopted in data reduction. The calculated local and average characteristics of flow and heat transfer are compared among different methods, and with the experiments, correlations and simplified theoretical solution data from published literatures. Compared with the inlet property method, both average and variable property methods have significantly lower f{sub app}, but higher convective heat transfer coefficient h{sub z} and Nu{sub z}. Compared with the average property method, the variable property method has higher f{sub app}Re{sub ave} and lower h{sub z} at the beginning, but lower f{sub app}Re{sub ave} and higher h{sub z} at the later section of the channel. The calculated Nu{sub ave} agree well with the Sieder-Tate correlation and the recently reported experiment, validating the traditional macroscale theory in predicting the flow and heat transfer characteristics in the dimension and Re range of the present work. (author)

  14. Heat transfer and flow in solar energy and bioenergy systems

    Science.gov (United States)

    Xu, Ben

    The demand for clean and environmentally benign energy resources has been a great concern in the last two decades. To alleviate the associated environmental problems, reduction of the use of fossil fuels by developing more cost-effective renewable energy technologies becomes more and more significant. Among various types of renewable energy sources, solar energy and bioenergy take a great proportion. This dissertation focuses on the heat transfer and flow in solar energy and bioenergy systems, specifically for Thermal Energy Storage (TES) systems in Concentrated Solar Power (CSP) plants and open-channel algal culture raceways for biofuel production. The first part of this dissertation is the discussion about mathematical modeling, numerical simulation and experimental investigation of solar TES system. First of all, in order to accurately and efficiently simulate the conjugate heat transfer between Heat Transfer Fluid (HTF) and filler material in four different solid-fluid TES configurations, formulas of an e?ective heat transfer coe?cient were theoretically developed and presented by extending the validity of Lumped Capacitance Method (LCM) to large Biot number, as well as verifications/validations to this simplified model. Secondly, to provide design guidelines for TES system in CSP plant using Phase Change Materials (PCM), a general storage tank volume sizing strategy and an energy storage startup strategy were proposed using the enthalpy-based 1D transient model. Then experimental investigations were conducted to explore a novel thermal storage material. The thermal storage performances were also compared between this novel storage material and concrete at a temperature range from 400 °C to 500 °C. It is recommended to apply this novel thermal storage material to replace concrete at high operating temperatures in sensible heat TES systems. The second part of this dissertation mainly focuses on the numerical and experimental study of an open-channel algae

  15. Numerical Study on Flow and Heat Transfer Performance of Rectangular Heat Sink with Compound Heat Transfer Enhancement Structures

    Directory of Open Access Journals (Sweden)

    Di Zhang

    2014-04-01

    Full Text Available Modern gas turbine blade is operating at high temperature which requires abundant cooling. Considering both heat transfer rate and pumping power for internal passages, developing efficient cooling passages is of great importance. Ribbed channel has been proved as effective heat transfer enhancement technology for considerable heat transfer characteristics; however, the pressure loss is impressive. Dimple and protrusion are frequently considered as new heat transfer augmentation tools for their low friction loss in recent years. Numerical simulations are adopted to investigate the thermal performance of rectangular channel with compound heat transfer enhancement structures with ribs, dimples, and protrusions. Among all configurations, the nondimensional dimple/protrusion depths are 0.2. The results present the flow structures of all channel configurations. The Nu/Nu0 distributions of channel section are discussed for each case. The pressure penalty f/f0 and the thermal performance TP are also considered as important parameters for heat transfer enhancement. It can be concluded that the optimal structure of the compound heat transfer enhancement structure is rib + protrusion (D = 6 mm + dimple (D = 15 mm.

  16. Nanofluid flow and forced convection heat transfer over a stretching surface considering heat source

    Science.gov (United States)

    Mohammadpour, M.; Valipour, P.; Shambooli, M.; Ayani, M.; Mirparizi, M.

    2015-07-01

    In this paper, magnetic field effects on the forced convection flow of a nanofluid over a stretching surface in the presence of heat generation/absorption are studied. The equations of continuity, momentum and energy are transformed into ordinary differential equations and solved numerically using the fourth-order Runge-Kutta integration scheme featuring the shooting technique. Different types of nanoparticles as copper (Cu), silver (Ag), alumina (Al2O3) and titania (TiO2) with water as their base fluid has been considered. The influence of significant parameters, such as magnetic parameter, volume fraction of the nanoparticles, heat generation/absorption parameter, velocity ratio parameter and temperature index parameter on the flow and heat transfer characteristics are discussed. The results show that the values of temperature profiles increase with increasing heat generation/absorption and volume fraction of the nanoparticles but they decrease with increasing velocity ratio parameter and temperature index parameter. Also, it can be found that selecting silver as nanoparticle leads to the highest heat transfer enhancement.

  17. Slip Flow and Radiative Heat Transfer on a Convectively Heated Vertical Cylinder

    Science.gov (United States)

    Das, S.; Jana, R. N.; Makinde, O. D.

    2017-05-01

    An axisymmetric laminar boundary-layer slip flow of a viscous incompressible rarefied gas in a convectively heated vertical cylinder in the presence of thermal radiation is analyzed. The governing equations in cylindrical coordinates are transformed into ordinary differential equations by similarity transformation. These transformed equations are then solved numerically, using the fourth order Runge-Kutta method with shooting technique. The effects of the pertinent parameters on the gas velocity, temperature, as well as on the shear stress and heat transfer rate at the cylinder surface, are estimated.

  18. Numerical Analysis of Heat Transfer and Fluid Flow in Heat Exchangers with Emphasis on Pin Fin Technology

    OpenAIRE

    2012-01-01

    One of the most important industrial processes is heat transfer, carried out by heat exchangers in single and multiphase flow applications. Despite the existence of well-developed theoretical models for different heat transfer mechanisms, the expanding need for industrial applications requiring the design and optimization of heat exchangers, has created a solid demand for experimental work and effort. This thesis concerns the use of numerical approaches to analyze and optimize heat transfer a...

  19. Determination of forced convective heat transfer coefficients for subsonic flows over heated asymmetric NANA 4412 airfoil

    Science.gov (United States)

    Dag, Yusuf

    Forced convection over traditional surfaces such as flat plate, cylinder and sphere have been well researched and documented. Data on forced convection over airfoil surfaces, however, remain very scanty in literature. High altitude vehicles that employ airfoils as lifting surfaces often suffer leading edge ice accretions which have tremendous negative consequences on the lifting capabilities and stability of the vehicle. One of the ways of mitigating the effect of ice accretion involves judicious leading edge convective cooling technique which in turn depends on the accuracy of convective heat transfer coefficient used in the analysis. In this study empirical investigation of convective heat transfer measurements on asymmetric airfoil is presented at different angle of attacks ranging from 0° to 20° under subsonic flow regime. The top and bottom surface temperatures are measured at given points using Senflex hot film sensors (Tao System Inc.) and used to determine heat transfer characteristics of the airfoils. The model surfaces are subjected to constant heat fluxes using KP Kapton flexible heating pads. The monitored temperature data are then utilized to determine the heat convection coefficients modelled empirically as the Nusselt Number on the surface of the airfoil. The experimental work is conducted in an open circuit-Eiffel type wind tunnel, powered by a 37 kW electrical motor that is able to generate subsonic air velocities up to around 41 m/s in the 24 square-inch test section. The heat transfer experiments have been carried out under constant heat flux supply to the asymmetric airfoil. The convective heat transfer coefficients are determined from measured surface temperature and free stream temperature and investigated in the form of Nusselt number. The variation of Nusselt number is shown with Reynolds number at various angles of attacks. It is concluded that Nusselt number increases with increasing Reynolds number and increase in angle of attack from 0

  20. Thermal and Hydraulic Performances of Nanofluids Flow in Microchannel Heat Sink with Multiple Zigzag Flow Channels

    Directory of Open Access Journals (Sweden)

    Duangthongsuk Weerapun

    2017-01-01

    Full Text Available This article presents an experimental investigation on the heat transfer performance and pressure drop characteristic of two types of nanofluids flowing through microchannel heat sink with multiple zigzag flow channel structures (MZMCHS. SiO2 nanoparticles dispersed in DI water with concentrations of 0.3 and 0.6 vol.% were used as working fluid. MZMCHS made from copper material with dimension of 28 × 33 mm. Hydraulic diameter of MZMCHs is designed at 1 mm, 7 number of flow channels and heat transfer area is about 1,238 mm2. Effects of particle concentration and flow rate on the thermal and hydraulic performances are determined and then compare with the common base fluid. The results indicated that the heat transfer coefficient of nanofluids was higher than that of the water and increased with increasing particle concentration as well as Reynolds number. For pressure drop, the particle concentrations have no significant effect on the pressure drop across the test section.

  1. Unsteady Flow in a Supersonic Turbine with Variable Specific Heats

    Science.gov (United States)

    Dorney, Daniel J.; Griffin, Lisa W.; Huber, Frank; Sondak, Douglas L.; Turner, James (Technical Monitor)

    2001-01-01

    Modern high-work turbines can be compact, transonic, supersonic, counter-rotating, or use a dense drive gas. The vast majority of modern rocket turbine designs fall into these Categories. These turbines usually have large temperature variations across a given stage, and are characterized by large amounts of flow unsteadiness. The flow unsteadiness can have a major impact on the turbine performance and durability. For example, the Space Transportation Main Engine (STME) fuel turbine, a high work, transonic design, was found to have an unsteady inter-row shock which reduced efficiency by 2 points and increased dynamic loading by 24 percent. The Revolutionary Reusable Technology Turbopump (RRTT), which uses full flow oxygen for its drive gas, was found to shed vortices with such energy as to raise serious blade durability concerns. In both cases, the sources of the problems were uncovered (before turbopump testing) with the application of validated, unsteady computational fluid dynamics (CFD) to the designs. In the case of the RRTT and the Alternate Turbopump Development (ATD) turbines, the unsteady CFD codes have been used not just to identify problems, but to guide designs which mitigate problems due to unsteadiness. Using unsteady flow analyses as a part of the design process has led to turbine designs with higher performance (which affects temperature and mass flow rate) and fewer dynamics problems. One of the many assumptions made during the design and analysis of supersonic turbine stages is that the values of the specific heats are constant. In some analyses the value is based on an average of the expected upstream and downstream temperatures. In stages where the temperature can vary by 300 to 500 K, however, the assumption of constant fluid properties may lead to erroneous performance and durability predictions. In this study the suitability of assuming constant specific heats has been investigated by performing three-dimensional unsteady Navier

  2. Turbulent flow heat transfer and pressure loss in a double pipe heat exchanger with triangular fins

    Directory of Open Access Journals (Sweden)

    Vinous M. Hameed, Bashar Muslem Essa

    2016-01-01

    Full Text Available Experimental investigation of heat transfer and friction factor characteristics in a double pipe heat exchanger with triangular fins was studied. The working fluids were air, flowing in the annular pipe, and water through the inner circular tube. The test section is consisting of two parts. The first part is an insulated tube which has been manufactured from Perspex material of (54mm inner diameter, (2000mm length and (3mm thickness. The second part is an internal copper tube without or with triangular copper fins. The smooth copper tube has (2250mm long and (20mm, 22mm inner and outer diameter respectively. The triangular fins were made of the copper with thickness of 0.3mm and 10mm height. They were installed on the straight copper tube section in three different cases (32, 27, and 22 mm distance between each two successive fins and (15mm pitch between each two of fins. Air at various mass flow rates (0.001875 to 0.003133 kg/sec flows through annuli and water at Reynold's numbers ranging from (10376.9 to 23348.03 flows through the inner tube. The inlet cold air and hot water temperatures are 30oC and 70oC, respectively. The experimental results showed an increase in convective heat transfer coefficient by decreasing in distance between two fins and by increasing Reynold's number. This is due to increase in surface area. It was found that (Space=22mm gives good heat transfer enhancement.

  3. A Numerical Study on Heat Transfer and Flow Characteristics of a Finned Downhole Coaxial Heat Exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chun Dong; Lee, Dong Hyun; Park, Byung-Sik; Choi, Jaejoon [Korea Institute of Energy Research (KIER), Daejeon (Korea, Republic of)

    2017-02-15

    In this study, the flow and heat transfer characteristics of the finned annular passage were investigated numerically. The annular passage simulates co-axial geothermal heat exchanger, and fins are installed on its inner wall to reduce heat loss from the production passage (annulus) to injection passage (inner pipe). A commercial CFD program, Ansys Fluent, was used with SST k-ω turbulence model. The effects of the geometric parameters of the fin on the inner tube were analyzed under the periodic boundary condition. The result indicated that most parameters had a tendency to increase with an increase in the height and angle of the fin. However, it was confirmed that the Nusselt number of the inner tube on the coaxial 15, 5, 0.3 was lower than that of the smooth tube. Additionally, the Nusselt number of the inner tube exhibited a tendency of decreasing with a decrease in the spacing in Coaxial 15, S{sub f}, 0.3.

  4. Theoretical investigation on thermal performance of heat pipe flat plate solar collector with cross flow heat exchanger

    Science.gov (United States)

    Xiao, Lan; Wu, Shuang-Ying; Zhang, Qiao-Ling; Li, You-Rong

    2012-07-01

    Based on the heat transfer characteristics of absorber plate and the heat transfer effectiveness-number of heat transfer unit method of heat exchanger, a new theoretical method of analyzing the thermal performance of heat pipe flat plate solar collector with cross flow heat exchanger has been put forward and validated by comparisons with the experimental and numerical results in pre-existing literature. The proposed theoretical method can be used to analyze and discuss the influence of relevant parameters on the thermal performance of heat pipe flat plate solar collector.

  5. Analytical methods for heat transfer and fluid flow problems

    CERN Document Server

    Weigand, Bernhard

    2015-01-01

    This book describes useful analytical methods by applying them to real-world problems rather than solving the usual over-simplified classroom problems. The book demonstrates the applicability of analytical methods even for complex problems and guides the reader to a more intuitive understanding of approaches and solutions. Although the solution of Partial Differential Equations by numerical methods is the standard practice in industries, analytical methods are still important for the critical assessment of results derived from advanced computer simulations and the improvement of the underlying numerical techniques. Literature devoted to analytical methods, however, often focuses on theoretical and mathematical aspects and is therefore useless to most engineers. Analytical Methods for Heat Transfer and Fluid Flow Problems addresses engineers and engineering students. The second edition has been updated, the chapters on non-linear problems and on axial heat conduction problems were extended. And worked out exam...

  6. Study on the heat transfer of cross flow in vertical upward tubes

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    A special device was designed to measure temperature difference in this study of heat transfer of water and oil cross flow inside vertical upward tubes. A new heat transfer correlation was obtained for cross flow. The experimental results showed that the dependence of heat transfer on Reynolds is much smaller in a narrow space than that in a wide space. It was found that the heat transfer correlation of cross flow in a narrow space is obviously different from that in a wide space, and that the heat transfer correlation obtained in a wide space may not be applicable to the cross-flow heat transfer in a narrow space. Further, the single-phase heat transfer capability of water cross flow was compared with that of oil cross flow. The experimental results showed that the average heat transfer coefficient of water is about 2~3 times that ofoil when they have the same superficial velocity.

  7. The effect of heating direction on flow boiling heat transfer of R134a in micro-channels

    Science.gov (United States)

    Xu, Mingchen; Jia, Li; Dang, Chao; Peng, Qi

    2017-04-01

    This paper presents effects of heating directions on heat transfer performance of R134a flow boiling in micro- channel heat sink. The heat sink has 30 parallel rectangular channels with cross-sectional dimensions of 500μm width 500μm depth and 30mm length. The experimental operation condition ranges of the heat flux and the mass flux were 13.48 to 82.25 W/cm2 and 373.3 to 1244.4 kg/m2s respectively. The vapor quality ranged from 0.07 to 0.93. The heat transfer coefficients of top heating and bottom heating both were up to 25 kW/m2 K. Two dominate transfer mechanisms of nucleate boiling and convection boiling were observed according to boiling curves. The experimental results indicated that the heat transfer coefficient of bottom heating was 13.9% higher than top heating in low heat flux, while in high heat flux, the heat transfer coefficient of bottom heating was 9.9%.higher than the top heating, because bubbles were harder to divorce the heating wall. And a modified correlation was provided to predict heat transfer of top heating.

  8. Paleo-heat flows, radioactive heat generation, and the cooling and deformation history of Mercury

    Science.gov (United States)

    Ruiz, Javier; López, Valle; Egea-González, Isabel

    2013-07-01

    Estimates of lithospheric strength for Mercury, based on the depth of thrust faults associated with large lobate scarps (which were most probably formed previously to ˜3 Ga) or on the effective elastic thickness of the lithosphere supporting a broad rise in the northern smooth plains (whose formation is poorly constrained, but posterior to 3.8 Ga), serve as a basis for the calculation of paleo-heat flows, referred to the time when these structures were formed. The so-obtained paleo-heat flows can give information on the Urey ratio (Ur), the ratio between the total radioactive heat production and the total surface heat loss. By imposing the condition Ur Urey ratio was lower, and the cooling more intense, than when most of large lobate scarps were formed. Thus, because largest lobate scarps deform older terrains (suggesting more intense contraction early in the mercurian history), we conclude that the northern rise was formed previously to 3 Ga. If the age of other smooth plains large wavelength deformations is similar, then tectonic activity in Mercury would have been limited in the last 3 billion of years.

  9. Pressure Drop and Heat Transfer of Water Flowing Shell-Side of Multitube Heat Exchangers

    Science.gov (United States)

    Ohashi, Yukio; Hashizume, Kenichi

    Experimental studies on heat transfer augmentation in water-flowing shell sides of counter flow multitube exchangers are presented. Various kinds of augmented tube bundles have been examined to obtain the characteristics of pressure drop and heat transfer. Data for a smooth tube bundle were a little different from those for the tube side. The pressure drop in the shell side depended on Re-0.4 and deviated from the tube side pressure drop to within +30%, while the shell side heat transfer coefficient depended on Re0.8 but about 35%. larger than that of the tube side. Furthermore the augmented tube bundles have been evaluated and compared using 21 evaluation criteria. Enhanced tube bundles, low-finned tube bundles and those with twisted tapes inserted had especially good performances. The ratios of increase in heat transfer were larger than those in pressure drop. In case of low-finned tube bundles, there seem to exist an optimum fin-pitch and an optimum relation between the fin-pitch and the pitch of twisted tapes inserted.

  10. Numerical Simulation of Flow and Heat Transfer of Nanofluid around a Heated Square Cylinder

    Directory of Open Access Journals (Sweden)

    Lotfi Bouazizi

    2016-01-01

    Full Text Available A numerical investigation was conducted to study the forced and mixed convection of nanofluid in a horizontal channel with a built-in-heated square cylinder. The nanofluid considered in this study is composed of metal nanoparticles(Cu suspended in water (base fluid. The governing equations are solved using the finite volume method based SIMPLER algorithm. Different Reynolds numbers and volume fractions of nanoparticles ranging respectively from Re= 85 to 200 and from φ= 0%to12%, have been considered. The effect of the nanoparticles volume fraction on the critical Reynolds number value defining the transition between two flow regimes (stationary and periodicas well as on the overall flow coefficients is firstly studied. In the thermal study, we have established correlations to evaluate the heat flux transferred from the obstacle to the flow for different nanoparticles volume fractions. Results show a marked improvement in heat transfer compared to the base fluid. This improvement is more pronounced for higher Richardson numbers and higher nanoparticles volume fractions.

  11. Injected power and entropy flow in a heated granular gas

    Science.gov (United States)

    Visco, P.; Puglisi, A.; Barrat, A.; Trizac, E.; van Wijland, F.

    2005-10-01

    Our interest goes to the power injected in a heated granular gas and to the possibility to interpret it in terms of entropy flow. We numerically determine the distribution of the injected power by means of Monte Carlo simulations. Then, we provide a kinetic-theory approach to the computation of such a distribution function. Finally, after showing why the injected power does not satisfy a fluctuation relation à la Gallavotti-Cohen, we put forward a new quantity which does fulfill such a relation, and is not only applicable in a variety of frameworks outside the granular world, but also experimentally accessible.

  12. Reattachment heating upstream of short compression ramps in hypersonic flow

    Science.gov (United States)

    Estruch-Samper, David

    2016-05-01

    Hypersonic shock-wave/boundary-layer interactions with separation induce unsteady thermal loads of particularly high intensity in flow reattachment regions. Building on earlier semi-empirical correlations, the maximum heat transfer rates upstream of short compression ramp obstacles of angles 15° ⩽ θ ⩽ 135° are here discretised based on time-dependent experimental measurements to develop insight into their transient nature (Me = 8.2-12.3, Re_h= 0.17× 105-0.47× 105). Interactions with an incoming laminar boundary layer experience transition at separation, with heat transfer oscillating between laminar and turbulent levels exceeding slightly those in fully turbulent interactions. Peak heat transfer rates are strongly influenced by the stagnation of the flow upon reattachment close ahead of obstacles and increase with ramp angle all the way up to θ =135°, whereby rates well over two orders of magnitude above the undisturbed laminar levels are intermittently measured (q'_max>10^2q_{u,L}). Bearing in mind the varying degrees of strength in the competing effect between the inviscid and viscous terms—namely the square of the hypersonic similarity parameter (Mθ )^2 for strong interactions and the viscous interaction parameter bar{χ } (primarily a function of Re and M)—the two physical factors that appear to most globally encompass the effects of peak heating for blunt ramps (θ ⩾ 45°) are deflection angle and stagnation heat transfer, so that this may be fundamentally expressed as q'_max∝ {q_{o,2D}} θ ^2 with further parameters in turn influencing the interaction to a lesser extent. The dominant effect of deflection angle is restricted to short obstacle heights, where the rapid expansion at the top edge of the obstacle influences the relaxation region just downstream of reattachment and leads to an upstream displacement of the separation front. The extreme heating rates result from the strengthening of the reattaching shear layer with the increase in

  13. CFD Study of Deteriorated Turbulent Heat Transfer in Upward Flow

    Energy Technology Data Exchange (ETDEWEB)

    Nietiadi, Yohanes Setiawan; Lee, Jeong Ik [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Addad, Yacine [Khalifa University of Science and Technology and Research, Abu Dhabi (United Arab Emirates)

    2014-10-15

    DTHT regime can be induced by two effects: buoyancy and acceleration. Apart from these two deteriorating effects, another unique behavior of fluid in the DTHT regime is that the convective heat transfer rate will continue to deteriorate until it reaches certain point. The downstream of this point, is known as the recovery region, where the convective heat transfer rate returns back to the high values by recovering turbulence. We called this phenomena as re-turbulization.. The map of the DTHT regime can be seen from fig. 2, where the x-axis is the buoyancy parameter and y-axis is the acceleration parameter which is the agreed governing non-dimensional numbers among the researchers to illustrate the phenomena. The Buoyancy parameter is defind in Eq. (1) and the acceleration parameter is defined in Eq. (2), respectively. The threshold value for both effects to move from the forced turbulent heat transfer to the DTHT regime are found to be Bo* ≥ 2x10{sup -6}and Kv ≥ 2.5x10{sup -6} in the previous works. Bo{sup *}=Gr{sub q}/Re{sup 3}'.{sup 425} Pr{sup 0}'.{sup 8} (1). K{sub v}=4q{sup +}/Re (2). Many experiments and simulation have been done to investigate this phenomenon and the boundary of the regime. However, very limited number of experiment was conducted in the regime where buoyancy effect and acceleration effect are in the same order of magnitude and high enough to cause DTHT (mixed DTHT). Some important experimental researches that have been done in the gas DTHT regime is Lee et al. who investigated the heat transfer of gas flow in the range of buoyancy parameter from 3x10{sup -9} to 10{sup -5} and acceleration parameter span from 6x10{sup -8} to 5x10{sup -6} and presented the behavior of Nusselt number ratio from the experiment as fig. 3 and fig. 4. This paper will discuss a Computational Fluid Dynamics analysis on DTHT by assuming hypothetical boundary conditions especially on the mixed DTHT regime. It has been found that a gas cooled fast reactor

  14. Physical quantity synergy in laminar flow field of convective heat transfer and analysis of heat transfer enhancement

    Institute of Scientific and Technical Information of China (English)

    LIU Wei; LIU ZhiChun; GUO ZengYuan

    2009-01-01

    Based on the principle of field synergy for heat transfer enhancement, the concept of physical quantity synergy in the laminar flow field is proposed in the present study according to the physical mechanism of convective heat transfer between fluid and tube wall. The synergy regulation among physical quantities of fluid particle is revealed by establishing formulas reflecting the relation between synergy angles and heat transfer enhancement. The physical nature of enhancing heat transfer and reducing flow resistance, which is directly associated with synergy angles α,βγ,φ, θ and ψ, is also explained. Be-sides, the principle of synergy among physical quantities is numerically verified by the calculation of heat transfer and flow in a thin cylinder-interpolated tube, which may guide the optimum design for better heat transfer unit and high-efficiency heat exchanger.

  15. Heat flow and thermal history of the Anadarko basin, Oklahoma

    Science.gov (United States)

    Carter, L.S.; Kelley, S.A.; Blackwell, D.D.; Naeser, N.D.

    1998-01-01

    New heat-flow values for seven sites in the Anadarko basin, Oklahoma, were determined using high-precision temperature logs and thermal conductivity measurements from nearly 300 core plugs. Three of the sites are on the northern shelf, three sites are in the deep basin, and one site is in the frontal fault zone of the northern Wichita Mountains. The heat flow decreased from 55 to 64 mW/m2 in the north, and from 39 to 54 mW/m2 in the south, due to a decrease in heat generation in the underlying basement rock toward the south. Lateral lithologic changes in the basin, combined with the change in heat flow across the basin, resulted in an unusual pattern of thermal maturity. The vitrinite reflectance values of the Upper Devonian-Lower Mississippian Woodford formation are highest 30-40 km north-northwest of the deepest part of the basin. The offset in highest reflectance values is due to the contrast in thermal conductivity between the Pennsylvanian "granite wash" section adjacent to the Wichita uplift and the Pennsylvanian shale section to the north. The geothermal gradient in the low-conductivity shale section is elevated relative to the geothermal gradient in the high-conductivity "granite wash" section, thus displacing the highest temperatures to the north of the deepest part of the basin. Apatite fission-track, vitrinite reflectance, and heat-flow data were used to constrain regional aspects of the burial history of the Anadarko basin. By combining these data sets, we infer that at least 1.5 km of denudation has occurred at two sites in the deep Anadarko basin since the early to middle Cenozoic (40 ?? 10 m.y.). The timing of the onset of denudation in the southern Anadarko basin coincides with the period of late Eocene erosion observed in the southern Rocky Mountains and in the northern Great Plains. Burial history models for two wells from the deep Anadarko basin predict that shales of the Woodford formation passed through the hydrocarbon maturity window by the

  16. Numerical heat conduction in hydrodynamical models of colliding hypersonic flows

    CERN Document Server

    Parkin, E R

    2010-01-01

    Hydrodynamical models of colliding hypersonic flows are presented which explore the dependence of the resulting dynamics and the characteristics of the derived X-ray emission on numerical conduction and viscosity. For the purpose of our investigation we present models of colliding flow with plane-parallel and cylindrical divergence. Numerical conduction causes erroneous heating of gas across the contact discontinuity which has implications for the rate at which the gas cools. We find that the dynamics of the shocked gas and the resulting X-ray emission are strongly dependent on the contrast in the density and temperature either side of the contact discontinuity, these effects being strongest where the postshock gas of one flow behaves quasi-adiabatically while the postshock gas of the other flow is strongly radiative. Introducing additional numerical viscosity into the simulations has the effect of damping the growth of instabilities, which in some cases act to increase the volume of shocked gas and can re-he...

  17. Estimation of respiratory heat flows in prediction of heat strain among Taiwanese steel workers

    Science.gov (United States)

    Chen, Wang-Yi; Juang, Yow-Jer; Hsieh, Jung-Yu; Tsai, Perng-Jy; Chen, Chen-Peng

    2017-01-01

    International Organization for Standardization 7933 standard provides evaluation of required sweat rate (RSR) and predicted heat strain (PHS). This study examined and validated the approximations in these models estimating respiratory heat flows (RHFs) via convection ( C res) and evaporation ( E res) for application to Taiwanese foundry workers. The influence of change in RHF approximation to the validity of heat strain prediction in these models was also evaluated. The metabolic energy consumption and physiological quantities of these workers performing at different workloads under elevated wet-bulb globe temperature (30.3 ± 2.5 °C) were measured on-site and used in the calculation of RHFs and indices of heat strain. As the results show, the RSR model overestimated the C res for Taiwanese workers by approximately 3 % and underestimated the E res by 8 %. The C res approximation in the PHS model closely predicted the convective RHF, while the E res approximation over-predicted by 11 %. Linear regressions provided better fit in C res approximation ( R 2 = 0.96) than in E res approximation ( R 2 ≤ 0.85) in both models. The predicted C res deviated increasingly from the observed value when the WBGT reached 35 °C. The deviations of RHFs observed for the workers from those predicted using the RSR or PHS models did not significantly alter the heat loss via the skin, as the RHFs were in general of a level less than 5 % of the metabolic heat consumption. Validation of these approximations considering thermo-physiological responses of local workers is necessary for application in scenarios of significant heat exposure.

  18. Free convection film flows and heat transfer laminar free convection of phase flows and models for heat-transfer analysis

    CERN Document Server

    Shang, De-Yi

    2012-01-01

    This book presents recent developments in our systematic studies of hydrodynamics and heat and mass transfer in laminar free convection, accelerating film boiling and condensation of Newtonian fluids, as well as accelerating film flow of non-Newtonian power-law fluids (FFNF). These new developments provided in this book are (i) novel system of analysis models based on the developed New Similarity Analysis Method; (ii) a system of advanced methods for treatment of gas temperature- dependent physical properties, and liquid temperature- dependent physical properties; (iii) the organically combined models of the governing mathematical models with those on treatment model of variable physical properties; (iv) rigorous approach of overcoming a challenge on accurate solution of three-point boundary value problem related to two-phase film boiling and condensation; and (v) A pseudo-similarity method of dealing with thermal boundary layer of FFNF for greatly simplifies the heat-transfer analysis and numerical calculati...

  19. Heat flow evolution of the Earth from paleomantle temperatures: Evidence for increasing heat loss since ∼2.5 Ga

    Science.gov (United States)

    Ruiz, Javier

    2017-08-01

    Earth currently loses two to five times as much heat through its surface as it is internally produced by radioactivity. This proportion cannot be extrapolated into the past, because it would imply high interior temperatures and catastrophic melting of the planet in ancient times. The heat loss evolution of the Earth cannot therefore be described by a constant heat flow decreasing. This is consistent with previous work finding that the mantle heated up until ∼2.5-3.0 Ga and then progressively cooled down. The present work derives a first-order heat loss evolution of the Earth by comparing the evolution of the total heat content of the silicate Earth (as described by mantle potential temperatures deduced from the melting conditions of ancient non-arc basalts) with the total radioactive heat production. The results show that the heat flow was declining, and the mantle heating-up, until ∼2.5 Ga, but that after this time the heat flow has been slowly (but constantly) increasing, and the mantle cooling-down, until the present-day. The change in heat loss trend is roughly coeval with other major geological, geochemical and environmental changes, and could indicate the starting of the modern-style of plate tectonics. This work provides therefore the first quantitative evidence of change in terrestrial heat loss regime, and suggests that substantial variations in the internal heat budget occurred during Earth's history.

  20. High resolution temperature measurement technique for measuring marine heat flow

    Institute of Scientific and Technical Information of China (English)

    QIN; YangYang; YANG; XiaoQiu; WU; BaoZhen; SUN; ZhaoHua; SHI; XiaoBin

    2013-01-01

    High resolution temperature measurement technique is one of the key techniques for measuring marine heat flow. Basing on Pt1000 platinum resistance which has the characteristics of high accuracy and good stability, we designed a bridge reversal excitation circuit for high resolution temperature measurement. And the deep ocean floor in-situ test results show that: (1) temperature deviation and peak-to-peak resolution of the first version circuit board (V1) are 1.960-1.990 mK and 0.980-0.995 m Kat 1.2-2.7°C, respectively; and temperature deviation and peak-to-peak resolution of the second circuit board (V2) are 2.260mK and 1.130 mK at 1.2-1.3°C, respectively; (2) During the 2012NSFC-IndOcean cruise, seafloor geothermal gradient at Ind2012HF03,-07 and-12 stations (water depth ranges from 3841 to 4541 m) were successfully measured, the values are 59.1,75.1 and 71.6°C/km, respectively. And the measurement errors of geothermal gradient at these three stations are less than 3.0% in terms of the peak-to-peak resolution. These indicate that the high resolution temperature measurement technique based on Pt1000 platinum resistance in this paper can be applied to marine heat flow measurement to obtain high precision geothermal parameters.

  1. High Heat Flux Burnout in Subcooled Flow Boiling

    Institute of Scientific and Technical Information of China (English)

    G.P.Celata; M.Cumo; 等

    1995-01-01

    The paper reports the results of an experimental research carried out at the Heat transfer divison of the Energy Department,C.R.Casaccia,on the thermal hydraulic characterization of subcooled flow boiling CHF under typical conditions of thermonuclear fusion reactors.I.e.high liquid velocity and subcooling.The experiment was carried out exploring the following parameters:channel diameter(from 2.5to 8.0 mm),heated length(10 and 15cm) ,liquid velocity (from 2 to 40m/s),exit pressure(from atmospheric to 5.0 MPa),inlet temperature(from 30 to 80℃),channel orientation (vertical and horizontal),A maximum CHF value of 60.6MW/m2 has been obtained under the following conditions:Tin-30°,p=2.5MPa,u=40m/s,D=2.5mm(smooth channel) Turbulence promoters(helically coiled wires)have been employed to further enhance the CHF attainable with subcooled flow boiling.Helically coiled wires allow an increase of 50% of the maximum CHF obtained with smooth channels.

  2. On the Nature of Feedback Heating in Cooling Flow Clusters

    CERN Document Server

    Pizzolato, F; Pizzolato, Fabio; Soker, Noam

    2004-01-01

    We study the feedback between heating and cooling of the intra-cluster medium (ICM) in cooling flow (CF) galaxies and clusters. We adopt the popular view that the heating is due to an active galactic nucleus (AGN), i.e. a central black hole accreting mass and launching jets and/or winds. We propose that the feedback occurs with the entire cool inner region (r2 cool fast and are removed from the ICM before experiencing the next major AGN heating event. We term this scenario cold-feedback. Some of these blobs cool and sink toward the central black hole, while others might form stars and cold molecular clouds. We derive the conditions under which the dense blobs formed by perturbations might cool to low temperatures (T < 10^4 K), and feed the black hole. The main conditions are found to be: (1) An over-dense blob must be prevented from reaching an equilibrium position in the ICM: therefore it has to cool fast, and the density profile of the ambient gas should be shallow; (2) Non-linear perturbations are requi...

  3. Finite time exergoeconomic performance optimization for an irreversible universal steady flow variable-temperature heat reservoir heat pump cycle model

    Directory of Open Access Journals (Sweden)

    Huijun Feng, Lingen Chen, Fengrui Sun

    2010-11-01

    Full Text Available An irreversible universal steady flow heat pump cycle model with variable-temperature heat reservoirs and the losses of heat-resistance and internal irreversibility is established by using the theory of finite time thermodynamics. The universal heat pump cycle model consists of two heat-absorbing branches, two heat-releasing branches and two adiabatic branches. Expressions of heating load, coefficient of performance (COP and profit rate of the universal heat pump cycle model are derived, respectively. By means of numerical calculations, heat conductance distributions between hot- and cold-side heat exchangers are optimized by taking the maximum profit rate as objective. There exist an optimal heat conductance distribution and an optimal thermal capacity rate matching between the working fluid and heat reservoirs which lead to a double maximum profit rate. The effects of internal irreversibility, total heat exchanger inventory, thermal capacity rate of the working fluid and heat capacity ratio of the heat reservoirs on the optimal finite time exergoeconomic performance of the cycle are discussed in detail. The results obtained herein include the optimal finite time exergoeconomic performances of endoreversible and irreversible, constant- and variable-temperature heat reservoir Brayton, Otto, Diesel, Atkinson, Dual, Miller and Carnot heat pump cycles.

  4. Flow regimes and mechanistic modeling of critical heat flux under subcooled flow boiling conditions

    Science.gov (United States)

    Le Corre, Jean-Marie

    Thermal performance of heat flux controlled boiling heat exchangers are usually limited by the Critical Heat Flux (CHF) above which the heat transfer degrades quickly, possibly leading to heater overheating and destruction. In an effort to better understand the phenomena, a literature review of CHF experimental visualizations under subcooled flow boiling conditions was performed and systematically analyzed. Three major types of CHF flow regimes were identified (bubbly, vapor clot and slug flow regime) and a CHF flow regime map was developed, based on a dimensional analysis of the phenomena and available data. It was found that for similar geometric characteristics and pressure, a Weber number (We)/thermodynamic quality (x) map can be used to predict the CHF flow regime. Based on the experimental observations and the review of the available CHF mechanistic models under subcooled flow boiling conditions, hypothetical CHF mechanisms were selected for each CHF flow regime, all based on a concept of wall dry spot overheating, rewetting prevention and subsequent dry spot spreading. It is postulated that a high local wall superheat occurs locally in a dry area of the heated wall, due to a cyclical event inherent to the considered CHF two-phase flow regime, preventing rewetting (Leidenfrost effect). The selected modeling concept has the potential to span the CHF conditions from highly subcooled bubbly flow to early stage of annular flow. A numerical model using a two-dimensional transient thermal analysis of the heater undergoing nucleation was developed to mechanistically predict CHF in the case of a bubbly flow regime. In this type of CHF two-phase flow regime, the high local wall superheat occurs underneath a nucleating bubble at the time of bubble departure. The model simulates the spatial and temporal heater temperature variations during nucleation at the wall, accounting for the stochastic nature of the boiling phenomena. The model has also the potential to evaluate

  5. Heat Flow Pattern in the Mainland of China and Its Geodynamic Significance

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    On the basis of 723 heat flow measurements in the mainland of China and over 2000 data from the global heat flow data set, the authors compiled the heat flow map of the mainland of China and its adjacent areas to exhibit the overall variation of the heat flow pattern in the mainland. The heat flow pattern of the mainland is complex, and can not be simply summarized as "low in the north and west and high in the south and east". Significant difference exists between eastern and western China in the spatial pattern of heat flow. Divided by the 105° E meridian, heat flow values in eastern China show a westward-decreasing trend; and a northward variation is observed in western China. The high-heat flow regions correspond to tectonically active belts such as Cenozoic orogens and extensional basins, where mantle heat flow is high; and the low-heat flow regions correspond to stable units such as the Tarim and Yangtze platforms. This heat flow pattern is controlled by India-Asia collision in the west and Pacific plate subduction in the east. The lateral variation in lithospheric strength corresponds to the heat flow variation, and there is a generally reversely proportional relation between heat flow and lithospheric strength in the mainland of China. The mosaic pattern of present deformation in the mainland results from lateral rheological heterogeneity. The good coincidence between weak strength domains and seismic zones demonstrates the intrinsic relation between the strength heterogeneity and regional seismicity pattern in the mainland of China.

  6. Flow Boiling Heat Transfer in Two-Phase Micro Channel Heat Sink at Low Water Mass Flux

    Science.gov (United States)

    Kuznetsov, Vladimir V.; Shamirzaev, Alisher S.

    2009-08-01

    Boiling heat transfer at water flow with low mass flux in heat sink which contained rectangular microchannels was studied. The stainless steel heat sink contained ten parallel microchannels with a size of 640 × 2050 μm in cross-section with typical wall roughness of 10-15 μm. The local flow boiling heat transfer coefficients were measured at mass velocity of 17 and 51 kg/m2s, heat flux on 30 to 150 kW/m2 and vapor quality of up to 0.8 at pressure in the channels closed to atmospheric one. It was observed that Kandlikar nucleate boiling correlation is in good agreement with the experimental data at mass flow velocity of 85 kg/m2s. At smaller mass flux the Kandlikar model and Zhang, Hibiki and Mishima model demonstrate incorrect trend of heat transfer coefficients variation with vapor quality.

  7. Homotopy perturbation method for heat transfer flow of a third grade fluid between parallel plates

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqui, A.M. [Pennsylvania State University, York Campus, York, PA 17403 (United States); Zeb, A. [COMSATS Institute of Information Technology, 30 H-8/1, Islamabad (Pakistan)], E-mail: amtaz56@yahoo.co.uk; Ghori, Q.K. [COMSATS Institute of Information Technology, 30 H-8/1, Islamabad (Pakistan); Benharbit, A.M. [Pennsylvania State University, York Campus, York, PA 17403 (United States)

    2008-04-15

    The present paper studies the heat transfer flow of a third grade fluid between two heated parallel plates for the constant viscosity model. Three flow problems, namely plane Couette flow, plane Poiseuille flow and plane Couette-Poiseuille flow have been considered. In each case the non-linear momentum equation and the energy equation have been solved using the homotopy perturbation method. Explicit analytical expressions for the velocity field and the temperature distribution have been derived.

  8. Methodology of heat transfer and flow resistance measurement for matrices of rotating regenerative heat exchangers

    Directory of Open Access Journals (Sweden)

    Butrymowicz Dariusz

    2016-09-01

    Full Text Available The theoretical basis for the indirect measurement approach of mean heat transfer coefficient for the packed bed based on the modified single blow technique was presented and discussed in the paper. The methodology of this measurement approach dedicated to the matrix of the rotating regenerative gas heater was discussed in detail. The testing stand consisted of a dedicated experimental tunnel with auxiliary equipment and a measurement system are presented. Selected experimental results are presented and discussed for selected types of matrices of regenerative air preheaters for the wide range of Reynolds number of gas. The agreement between the theoretically predicted and measured temperature profiles was demonstrated. The exemplary dimensionless relationships between Colburn heat transfer factor, Darcy flow resistance factor and Reynolds number were presented for the investigated matrices of the regenerative gas heater.

  9. The heat-transfer performance of gas—solid trickle flow over a regularly stacked packing

    NARCIS (Netherlands)

    Verver, A.B.; Swaaij, van W.P.M.

    1986-01-01

    The heat-transfer behaviour of a countercurrent gas—solid trickle flow contactor is studied, using coarse sand particles as the solids phase. Experimental data on the overall heat-transfer rate constant between the gas flow and the solid particle flow were obtained in a 0.15 m square cross-section c

  10. Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV

    Directory of Open Access Journals (Sweden)

    S. Sangiamsuk

    2013-01-01

    Full Text Available This research was to study the internal flow patterns on heat transfer rates of the Horizontal Heat Mode Closed Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV. The HHMCLOHP/CV was made from a Pyrex glass capillary tube with a 2.4 mm inside diameter. There were 10 meandering turns with 2 check valves. Ethanol and a silver nano-ethanol mixture were used as working fluid. Experimental results found that if working fluid varies from ethanol to a silver nano-ethanol mixture and the evaporator temperature increases the main flow patterns were Slug flow + Annular flow. The main regime of each flow pattern can be determined from the flow pattern map.

  11. Heat flow effect on the plasma line frequency

    Energy Technology Data Exchange (ETDEWEB)

    Kofman, W.; St.Maurice, J.P. (Centre d' Etude des Phenomenes Aleatories et Geophysique, St. Martin d' Heres (France)); Eyken A.P. van (EISCAT Scientific Association, Ramfjordmoen (Norway))

    1993-04-01

    The authors report on new electron plasma line experiments performed from the Tromso radar station, in the backscatter mode, which means they used the downshifted and upshifted plasma lines. The data were collected in May, 1992, on three days which were very quiet magnetically. They observe a bias between the upshifted and downshifted lines and the calculated results from evaluation of the standard dispersion relations. The authors are able to account for this difference by adding a heat flow term involving electrons to the standard theoretical model. This correction is important if one is looking at systematics in the differences in these two measurement modes with accuracies in the kHz range. It is also a factor of import if one is making measurements in areas where the temperature gradient can be 1 K/km or more.

  12. Microscale flow and heat transfer between rotating disks

    Energy Technology Data Exchange (ETDEWEB)

    Jiji, Latif M., E-mail: jiji@ccny.cuny.ed [Department of Mechanical Engineering, City College of the City University of New York, New York, NY 10031 (United States); Ganatos, Peter, E-mail: ganatos@ccny.cuny.ed [Department of Mechanical Engineering, City College of the City University of New York, New York, NY 10031 (United States)

    2010-08-15

    In this paper we consider steady laminar flow and heat transfer generated by two infinite parallel disks separated by a gas-filled micro-gap {delta}. One disk rotates with angular velocity {Omega} and the second with angular velocity s{Omega}. The analysis takes into consideration velocity slip, temperature jump, rarefaction and dissipation. A solution based on similarity transformation is obtained and used to examine the effects of the governing parameters on the velocity field, temperature distribution, disks' torque and power, and Nusselt number. The solution requires numerical integration of the resulting coupled ordinary non-linear differential equations. An exact analytical solution is obtained for the limiting case of small Reynolds numbers.

  13. Flow and heat transfer characteristics of magnetic nanofluids: A review

    Energy Technology Data Exchange (ETDEWEB)

    Bahiraei, Mehdi, E-mail: m.bahiraei@kut.ac.ir [Mechanical Engineering Department, School of Energy, Kermanshah University of Technology, Kermanshah (Iran, Islamic Republic of); Hangi, Morteza [School of Mechanical Engineering, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of)

    2015-01-15

    Magnetic nanofluids (MNFs) are suspensions which are comprised of a non-magnetic base fluid and magnetic nanoparticles. In this modern set of suspensions which can be called smart or functional fluids, fluid flow, particles movement and heat transfer process can be controlled by applying magnetic fields. Regarding unique characteristics of MNFs, studies in this field have witnessed a phenomenal growth. This paper reviews and summarizes recent investigations implemented on MNFs including those conducted on thermophysical properties, natural convection, forced convection, boiling as well as their practical applications. Moreover, this review identifies the challenges and opportunities for future research. - Highlights: • A review on recent studies on magnetic nanofluids in the field of thermal engineering. • Different categories such as properties, natural and forced convection, and boiling. • Practical applications of magnetic nanofluids in the field of thermal engineering. • Identifying the challenges and opportunities for future research.

  14. Heat Transfer in MHD Squeezing Flow using Brinkman Model

    Directory of Open Access Journals (Sweden)

    Satish Chandra RAJVANSHI

    2014-01-01

    Full Text Available This study investigates squeezing flow of viscous incompressible fluid in a highly permeable medium between 2 parallel, permeable, unsteadily rotating plates in the presence of a magnetic field and radiation. The plates at time t* are separated by a distance H(1-at*1/2. Using a similarity transformation, the governing equations have been transformed into a system of non-linear ordinary differential equations. The resulting equations have been solved numerically by a shooting method. Graphs are presented to depict the temperature and heat transfer profiles. The results show a decline in the temperature profiles under the effect of enhanced radiation.doi:10.14456/WJST.2014.68

  15. Heat transfer measurements on biconics at incidence in hypersonic high enthalpy air and nitrogen flows

    Science.gov (United States)

    Gai, S. L.; Cain, T.; Joe, W. S.; Sandeman, R. J.; Miller, C. G.

    1988-01-01

    Heat transfer rate measurements have been obtained at 0, 5, 15, and 21 deg angles-of-attack for a straight biconic scale model of an aeroassisted orbital vehicle proposed for planetary probe missions. Heat-transfer distributions were measured using palladium thin-film resistance gauges deposited on a glass-ceramic substrate. The windward heat transfer correlations were based on equilibrium flow in the shock layer of the model, although the flow may depart from equilibrium in the flow-field.

  16. A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus

    Energy Technology Data Exchange (ETDEWEB)

    Raustad, Richard A. [Florida Solar Energy Center

    2013-01-01

    This paper provides an overview of the variable refrigerant flow heat pump computer model included with the Department of Energy's EnergyPlusTM whole-building energy simulation software. The mathematical model for a variable refrigerant flow heat pump operating in cooling or heating mode, and a detailed model for the variable refrigerant flow direct-expansion (DX) cooling coil are described in detail.

  17. Study on heat transfer for falling liquid film flow with consideration of interfacial evaporation

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The interfacial evaporative heat transfer was included in the semi-empirical study of the heat transfer for the falling liquid film flow. The investigations showed that, the inclusion of the interfacial evaporative heat transfer in the turbulent model would lower the predicted convective heat transfer coefficient. Predictions of the new model resulted in a prominent deviation from that predictions of the normal model in the case of large mass flow rate and low wall heat flux. This deviation will be decreased with increasing wall heat flux, such that it will be asymptotic zero at very high wall heat flux. Predictions of the new model agreed well with the current experimental measurements. This study has verified that the Reynolds number is not the sole crucial parameter for heat transfer of falling liquid film flow, and wall heat flux will be another important independent parameter. This result is consistent with our previous studies.

  18. Convective heat transfer in supercritical flows of CO{sub 2} in tubes with and without flow obstacles

    Energy Technology Data Exchange (ETDEWEB)

    Eter, Ahmad, E-mail: eng.eter@yahoo.com; Groeneveld, Dé, E-mail: degroeneveld@gmail.com; Tavoularis, Stavros, E-mail: stavros.tavoularis@uottawa.ca

    2017-03-15

    Highlights: • Measurements of supercritical heat transfer in tubes equipped with obstacles were obtained and compared with results in base tubes. • In general, flow obstacles improve supercritical heat transfer, but under certain conditions have a negative effect on it. • New correlations describing obstacle-enhanced supercritical heat transfer in the liquid-like and gas-like regimes are fitted to the data. - Abstract: Heat transfer measurements to CO{sub 2}-cooled tubes with and without flow obstacles at supercritical pressures were obtained at the University of Ottawa’s supercritical pressure test facility. The effects of obstacle geometry (obstacle pitch, obstacle shape, flow blockage) on the wall temperature and heat transfer coefficient were investigated. Tests were performed for vertical upward flow in a directly heated 8 mm ID tube for a pressure range from 7.69 to 8.36 MPa, a mass flux range from 200 to 1184 kg/m{sup 2} s, and a heat flux range from 1 to 175 kW/m{sup 2}. The results are presented graphically in plots of wall temperature and heat transfer coefficient vs. bulk specific enthalpy of the fluid. The effects of flow parameters and flow obstacle geometry on supercritical heat transfer for both normal and deteriorated heat transfer are discussed. A comparison of the measurements with leading prediction methods for supercritical heat transfer in bare tubes and for spacer effects is also presented. The optimum increase in heat transfer coefficient was found to be for blunt obstacles, having a large flow blockage, and a short obstacle pitch.

  19. An advanced thin foil sensor concept for heat flux and heat transfer measurements in fully turbulent flows

    Science.gov (United States)

    Mocikat, H.; Herwig, H.

    2007-02-01

    A double layer hot film with two 10 μm nickel foils, separated by a 25 μm polyimide foil is used as a multi-purpose sensor. Each foil can be operated as a (calibrated) temperature sensor in its passive mode by imposing an electric current small enough to avoid heating by dissipation of electrical energy. Alternatively, however, each foil can also serve as a heater in an active mode with electric currents high enough to cause Joule heating. This double foil sensor can be used as a conventional heat flux sensor in its passive mode when mounted on an externally heated surface. Together with the wall and free stream temperature this measured heat flux will provide the local heat transfer coefficient h = dot{q}w/left(Tw - T_{infty}right). In fully turbulent flows it alternatively can be operated in an active mode on a cold, i.e. not externally heated surface. Then, by heating the upper foil, a local heat transfer is initiated from which the local heat transfer coefficient h can be determined, once the lower foil is heated to the same temperature as the upper one, thus acting as a counter-heater. The overall concept behind this mode of measurement is based on the local character of heat transfer in fully turbulent flows which turns out to be almost independent of the upstream thermal events.

  20. Transient critical heat flux under flow coast-down in vertical annulus with non-uniform heat flux distribution

    Energy Technology Data Exchange (ETDEWEB)

    Moon, S.K.; Chun, S.Y.; Choi, K.Y.; Yang, S.K. [Korea Atomic Energy Research Inst., Taejon (Korea, Republic of)

    2001-07-01

    An experimental study on transient critical heat flux (CHF) under flow coast-down has been performed for water flow in a non-uniformly heated vertical annulus under low flow and a wide range of pressure conditions. The objectives of this study are to systematically investigate the effect of the flow transient on the CHF and to compare the transient CHF with steady state CHF. The transient CHF experiments have been performed for three kinds of flow transient modes based on the coast-down data of the Kori 3/4 nuclear power plant reactor coolant pump. Most of the CHFs occurred in the annular-mist flow regime. Thus, it means that the possible CHF mechanism might be the liquid film dryout in the annular-mist flow regime. For flow transient mode with the smallest flow reduction rate, the time-to-CHF is the largest. At the same inlet subcooling, system pressure and heat flux, the effect of the initial mass flux on the critical mass flux can be negligible. However, the effect of the initial mass flux on the time-to-CHF becomes large as the heat flux decreases. Usually, the critical mass flux is large for slow flow reduction. There is a pressure effect on the ratio of the transient CHF data to steady state CHF data. Some conventional correlations show relatively better CHF prediction results for high system pressure, high quality and slow transient modes than for low system pressure, low quality and fast transient modes. (author)

  1. Heat transfer of bubbly flow on inner wall of annular channel

    Directory of Open Access Journals (Sweden)

    Lobanov Pavel

    2017-01-01

    Full Text Available Experimental investigations of heat transfer from the heated wall to the two-phase bubbly flow were performed in vertical annular channel using air-water system. The IR-thermography and miniature temperature sensors were used to measure heat transfer coefficients. The influence of bubbles on heat transfer is shown in comparison with the case of single phase flow. The presence of bubbles in the flow leads to heat transfer intensification in the annular channel even for low void fractions.

  2. Constraints on lithospheric thermal structure for the Indian Ocean from depth and heat flow data

    Science.gov (United States)

    Shoberg, Tom; Stein, Carol A.; Stein, Seth

    1993-06-01

    Models for the thermal evolution of oceanic lithosphere are primarily constrained by variations in seafloor depth and heat flow with age. These models have been largely based on data from the Pacific and Atlantic Ocean basins. We construct seafloor age relations for the Indian Ocean which we combine with bathymetric, sediment isopach and heat flow data to derive curves for depth and heat flow versus age. Comparison of these curves with predictions from three thermal models shows that they are better fit by the shallower depths and higher heat flow for the GDH1 model, which is characterized by a thinner and hotter lithosphere than previous models.

  3. Numerical Heat Transfer Prediction for Laminar Flow in a Circular Pipe with a 90° Bend

    Science.gov (United States)

    Patro, Pandaba; Rout, Ani; Barik, Ashok

    2017-05-01

    Laminar air flow in a 90° bend has been studied numerically to investigate convective heat transfer, which is of practical relevance to electronic systems and refrigeration piping layout. CFD simulations are performed for Reynolds number in the range 200 to 1000 at different bend radius ratios (5, 10 and 20). The heat transfer characteristics are found to be enhanced in the curved pipe compared to a straight pipe, which are subjected to the same flow rate. The curvature and buoyancy effectively increase heat transfer in viscous laminar flows. The correlation between the flow structure and the heat transfer is found to be strong.

  4. Influence of compression-expansion effect on oscillating-flow heat transfer in a finned heat exchanger

    Institute of Scientific and Technical Information of China (English)

    Ke TANG; Juan YU; Tao JIN; Zhi-hua GAN

    2013-01-01

    Compression and expansion of a working gas due to the pressure oscillation of an oscillating flow can lead to a temperature variation of the working gas,which will affect the heat transfer in the oscillating flow.This study focuses on the impact of the compression-expansion effect,indicated by the pressure ratio,on the heat transfer in a finned heat exchanger under practical operating conditions of the ambient-temperature heat exchangers in Stirling-type pulse tube refrigerators.The experimental results summarized as the Nusselt number are presented for analysis.An increase in the pressure ratio can result in a marked rise in the Nussclt number,which indicates that the compression-expansion effect should be considered in characterizing the heat transfer of the oscillating flow,especially in the cases with a higher Valensi number and a lower maximum Reynolds number.

  5. Heat flow, heat production, and crustal dynamics in the Central Alps, Switzerland

    Energy Technology Data Exchange (ETDEWEB)

    Rybach, L. (Inst. of Geophysics, Zurich); Werner, D.; Mueller, S.; Berset, G.

    1977-08-03

    Interrelations between temperature field, crustal structure, and crustal dynamics (vertical crustal movements) were investigated along a selected profile: the Swiss Geotraverse which cross-sects in a NW--SE direction the following tectonic units: Rhine-Graben, Jura Mountains, Molasse Basin, Helvetic Nappes, Central Massifs with autochthonous cover, Penninic units, basement and sedimentary units of the Southern Alps (total length: 220 km). The corrected heat flow is slightly elevated along or close to the traverse (approximately equal to 75 mW/m/sup 2/). Thermal effects of Alpine overthrusting and metamorphism on the surface gradient are negligible today. For steady-state calculations of the temperature field heat production was determined experimentally for surface samples; for deep crustal rocks it was inferred from an empirical relationship between heat production and seismic compressional wave velocity or density. The temperature field shows downwarped isotherms where a pronounced inversion of seismic velocity and density occurs in the upper crust. The same area of the Central Alps (Lepontine gneiss region) exhibits the strongest recent crustal movements (vertical uplift approximately equal to 1 mm/yr). The Mohorovicic discontinuity is clearly not an isothermal surface; its asymmetric shape found by seismic and gravimetric measurements is likely to be a result of the early Alpine subduction tectonics.

  6. Secondary flow and heat transfer coefficient distributions in the developing flow region of ribbed turbine blade cooling passages

    Science.gov (United States)

    Forsyth, Peter; McGilvray, Matthew; Gillespie, David R. H.

    2017-01-01

    This paper reports an experimental and numerical study of the development and coupling of aerodynamic flows and heat transfer within a model ribbed internal cooling passage to provide insight into the development of secondary flows. Static instrumentation was installed at the end of a long smooth passage and used to measure local flow features in a series of experiments where ribs were incrementally added upstream. This improves test turnaround time and allows higher-resolution heat transfer coefficient distributions to be captured, using a hybrid transient liquid crystal technique. A composite heat transfer coefficient distribution for a 12-rib-pitch passage is reported: notably the behaviour is dominated by the development of the secondary flow in the passage throughout. Both the aerodynamic and heat transfer test data were compared to numerical simulations developed using a commercial computational fluid dynamics solver. By conducting a number of simulations it was possible to interrogate the validity of the underlying assumptions of the experimental strategy; their validity is discussed. The results capture the developing size and strength of the vortical structures in secondary flow. The local flow field was shown to be strongly coupled to the enhancement of heat transfer coefficient. Comparison of the experimental and numerical data generally shows excellent agreement in the level of heat transfer coefficient predicted, though the numerical simulations fail to capture some local enhancement on both the ribbed and smooth surfaces. Where this was the case, the coupled flow and heat transfer measurements were able to identify missing velocity field characteristics.

  7. Study of the heat-transfer crisis on heat-release surfaces of annular channels with swirl and transit flows

    Science.gov (United States)

    Boltenko, E. A.

    2016-10-01

    The results of the experimental study of the heat-transfer crisis on heat-release surfaces of annular channels with swirl and transit flow are presented. The experiments were carried out using electric heated annular channels with one and (or) two heat-release surfaces. For the organization of transit flow on a convex heat-release surface, four longitudinal ribs were installed uniformly at its perimeter. Swirl flow was realized using a capillary wound tightly (without gaps) on the ribs. The ratio between swirl and transit flows in the annular gap was varied by applying longitudinal ribs of different height. The experiments were carried out using a closed-type circulatory system. The experimental data were obtained in a wide range of regime parameters. Both water heated to the temperature less than the saturation temperature and water-steam mixture were fed at the inlet of the channels. For the measurement of the temperature of the heat-release surfaces, chromel-copel thermocouples were used. It was shown that the presence of swirl flow on a convex heatrelease surface led to a significant decrease in critical heat flows (CHF) compared to a smooth surface. To increase CHF, it was proposed to use the interaction of swirl flows of the heat carrier. The second swirl flow was transit flow, i.e., swirl flow with the step equal to infinity. It was shown that CHF values for a channel with swirl and transit flow in all the studied range of regime parameters was higher than CHF values for both a smooth annular channel and a channel with swirl. The empirical ratios describing the dependence of CHF on convex and concave heat-release surfaces of annular channels with swirl and transit flow on the geometrical characteristics of channels and the regime parameters were obtained. The experiments were carried out at the pressure p = 3.0-16.0 MPa and the mass velocity ρw = 250-3000 kg/(m2s).

  8. Effect of heat source on MHD free convection flow past an oscillating porous plate in the slip flow regime

    Directory of Open Access Journals (Sweden)

    S. S. Das, L. K. Mishra, P. K. Mishra

    2011-09-01

    Full Text Available This paper investigates the effect of heat source on free convective flow of a viscous incompressible electrically conducting fluid through a porous medium bounded by an oscillating porous plate in the slip flow regime in presence of a transverse magnetic field. The governing equations of the flow field are solved analytically and the expressions for velocity, temperature, skin friction t and the heat flux in terms of Nusselts number Nu are obtained. The effects of the important flow parameters such as magnetic parameter M, permeability parameter Kp, Grashof number for heat transfer Gr, heat source parameter S and rarefaction parameter R on the velocity of the flow field are analyzed quantitatively with the help of figures.

  9. Vapor Flow Patterns During a Start-Up Transient in Heat Pipes

    Science.gov (United States)

    Issacci, F.; Ghoniem, N, M.; Catton, I.

    1996-01-01

    The vapor flow patterns in heat pipes are examined during the start-up transient phase. The vapor core is modelled as a channel flow using a two dimensional compressible flow model. A nonlinear filtering technique is used as a post process to eliminate the non-physical oscillations of the flow variables. For high-input heat flux, multiple shock reflections are observed in the evaporation region. The reflections cause a reverse flow in the evaporation and circulations in the adiabatic region. Furthermore, each shock reflection causes a significant increase in the local pressure and a large pressure drop along the heat pipe.

  10. Evaluation of correlations of flow boiling heat transfer of R22 in horizontal channels.

    Science.gov (United States)

    Zhou, Zhanru; Fang, Xiande; Li, Dingkun

    2013-01-01

    The calculation of two-phase flow boiling heat transfer of R22 in channels is required in a variety of applications, such as chemical process cooling systems, refrigeration, and air conditioning. A number of correlations for flow boiling heat transfer in channels have been proposed. This work evaluates the existing correlations for flow boiling heat transfer coefficient with 1669 experimental data points of flow boiling heat transfer of R22 collected from 18 published papers. The top two correlations for R22 are those of Liu and Winterton (1991) and Fang (2013), with the mean absolute deviation of 32.7% and 32.8%, respectively. More studies should be carried out to develop better ones. Effects of channel dimension and vapor quality on heat transfer are analyzed, and the results provide valuable information for further research in the correlation of two-phase flow boiling heat transfer of R22 in channels.

  11. Revised conceptualization of the North China Basin groundwater flow system: Groundwater age, heat and flow simulations

    Science.gov (United States)

    Cao, Guoliang; Han, Dongmei; Currell, Matthew J.; Zheng, Chunmiao

    2016-09-01

    Groundwater flow in deep sedimentary basins results from complex evolution processes on geological timescales. Groundwater flow systems conceptualized according to topography and/or groundwater table configuration generally assume a near-equilibrium state with the modern landscape. However, the time to reach such a steady state, and more generally the timescales of groundwater flow system evolution are key considerations for large sedimentary basins. This is true in the North China Basin (NCB), which has been studied for many years due to its importance as a groundwater supply. Despite many years of study, there remain contradictions between the generally accepted conceptual model of regional flow, and environmental tracer data. We seek to reconcile these contractions by conducting simulations of groundwater flow, age and heat transport in a three dimensional model, using an alternative conceptual model, based on geological, thermal, isotope and historical data. We infer flow patterns under modern hydraulic conditions using this new model and present the theoretical maximum groundwater ages under such a flow regime. The model results show that in contrast to previously accepted conceptualizations, most groundwater is discharged in the vicinity of the break-in-slope of topography at the boundary between the piedmont and central plain. Groundwater discharge to the ocean is in contrast small, and in general there are low rates of active flow in the eastern parts of the basin below the central and coastal plain. This conceptualization is more compatible with geochemical and geothermal data than the previous model. Simulated maximum groundwater ages of ∼1 Myrs below the central and coastal plain indicate that residual groundwater may be retained in the deep parts of the basin since being recharged during the last glacial period or earlier. The groundwater flow system has therefore probably not reached a new equilibrium state with modern-day hydraulic conditions. The

  12. Heat transfer and flow resistance performance of shutter baffle heat exchanger with triangle tube layout in shell side

    OpenAIRE

    Xin Gu; Bing Liu; Yongqing Wang; Ke Wang

    2016-01-01

    Effect of main structural parameters of shutter baffle heat exchanger with a triangle tube layout in the shell side on heat transfer and flow resistance performance is studied in the article. A periodic whole cross-sectional computation model is built for the heat exchanger in the numerical study. The effects of structural parameters are analyzed, including assembly mode of shutter baffles, shutter baffle pitch, strip inclination angles, and strip widths. The correctness and accuracy of numer...

  13. Heat flow map of Europe: brief summary of the geophysical implications

    Energy Technology Data Exchange (ETDEWEB)

    Cermak, V.

    1981-01-01

    The map of the surface heat flow in Europe was supplemented with the crustal thickness pattern, data on crustal radioactivity and conductivity and with available information on the heat flow-tectonic age, heat flow-heat generation and heat flow-crustal thickness relationships. Using this material and discussing it in terms of the crustal structure, generalized one-dimensional steady-state conductive temperature-depth curves were calculated for major tectonic provinces of Europe. Converting the seismic velocities to heat generation data, a preliminary pattern of the Moho heat flow was proposed. The Mohorovicic discontinuity is clearly not an isothermal surface, neither is the outflow of heat from the upper mantle constant, but both parameters may vary in broad ranges. For a more refined model of the crust and upper mantle, the characteristic geotherms were computed, using surface heat flow as the determining parameter. By equating the depths, at which geotherms intersect the mantle solidus, with the depth of the lithosphere base, the surface heat flow pattern was used to map regional variations of the lithospheric thickness. 52 references, 11 figures.

  14. NUMERICAL STUDY ON FLOW DISTRIBUTION IN PLATE-FIN HEAT EXCHANGERS

    Institute of Scientific and Technical Information of China (English)

    张哲; 厉彦忠

    2003-01-01

    Objective To investigate the flow distribution in plate-fin heat exchangers and optimize the design of header configuration for plate-fin heat exchangers. Methods A mathematical model of header was proposed. The effects of the header configuration on the flow distribution in plate-fin heat exchangers were investigated by CFD. The second header configuration with a two-stage-distributing structure was brought forward to improve the performance of flow distribution. Results It is found that the flow maldistribution is very serious in the direction of header length for the conventional header used in industry. The numerical predictions indicate that the improved header configurations can effectively improve the performance of flow distribution in plate-fin heat exchangers. Conclusion The numerical simulation confirms that CFD should be a suitable tool for predicting the flow distribution. The method has a wide variety of applications in the design of plate-fin heat exchangers.

  15. THEORETICAL AND EXPERIMENTAL ANALYSIS OF A CROSS-FLOW HEAT EXCHANGER

    Directory of Open Access Journals (Sweden)

    R. Tuğrul OĞULATA

    1996-03-01

    Full Text Available In this study, cross-flow plate type heat exchanger has been investigated because of its effective use in waste heat recovery systems. For this purpose, a heat regain system has been investigated and manufactured in laboratory conditions. Manufactured heat exchanger has been tested with an applicable experimental set up and temperatures, velocity of the air and the pressure losses occuring in the system have been measured and the efficiency of the system has been determined. The irreversibility of heat exchanger has been taken into consideration while the design of heat exchanger is being performed. So minimum entropy generation number has been analysied with respect to second law of thermodynamics in cross-flow heat exchanger. The minimum entropy generation number depends on parameters called optimum flow path length, dimensionless mass velocity and dimensionless heat transfer area. Variations of entropy generation number with these parameters have been analysied and introduced their graphics with their comments.

  16. Flow Patterns and Thermal Drag in a One-Dimensional Inviscid Channel with Heating or Cooling

    Institute of Scientific and Technical Information of China (English)

    1993-01-01

    In this paper investigations on the flow patterns and the thermal drag phenomenon in one -dimensional inviscid channel flow with heating or cooling are described and discussed:expressions of flow rate ratio and thermal drag coefficient for different flow patterns and its physical mechanism are presented.

  17. Heat flow and temperature-depth curves throughout Alaska: finding regions for future geothermal exploration

    Science.gov (United States)

    Batir, Joseph F.; Blackwell, David D.; Richards, Maria C.

    2016-06-01

    The objective of this research is to contribute to the understanding of the thermal regime of Alaska and its relationship to geology, regional tectonics, and to suggest potential sites for future geothermal energy production. New heat flow data were collected and are combined with existing published and unpublished data, although large sections of Alaska still lack data. Fault traces were implemented into the heat flow contouring as an additional gridding constraint, to incorporate both heat flow measurements and geology. New heat flow data supported the use of geologic trends in the heat flow mapping procedure, and a heat flow map of Alaska was produced with this added constraint. The multi-input contouring strategy allows production of a map with a regional interpretation of heat flow, in addition to site-specific heat flow and thermal model interpretations in areas with sufficient data density. Utilizing the new heat flow map, temperature-at-depth curves were created for example areas. Temperature-at-depth curves are calculated to 10 km depth for the areas of Anchorage, Fairbanks, Juneau, the Alaska Peninsula, Bristol Bay, and the Copper River Basin. The temperatures-at-depth predicted near the population centers of Anchorage and Juneau are relatively low, limiting the geothermal resource potential. The Fairbanks area temperature estimates are near conventional power production temperatures (150 °C) between 3.5 and 4 km. All data areas, except at Juneau, have temperatures sufficient for low temperature geothermal applications (40 °C) by 2 km. A high heat flow region exists within the Aleutian Volcanic Arc, although new data show heat flow variations from 59 to 120 mW m-2, so individual geothermal resources within the arc will be irregularly located.

  18. Homotopy Perturbation Method for Thin Film Flow and Heat Transfer over an Unsteady Stretching Sheet with Internal Heating and Variable Heat Flux

    Directory of Open Access Journals (Sweden)

    I-Chung Liu

    2012-01-01

    Full Text Available We have analyzed the effects of variable heat flux and internal heat generation on the flow and heat transfer in a thin film on a horizontal sheet in the presence of thermal radiation. Similarity transformations are used to transform the governing equations to a set of coupled nonlinear ordinary differential equations. The obtained differential equations are solved approximately by the homotopy perturbation method (HPM. The effects of various parameters governing the flow and heat transfer in this study are discussed and presented graphically. Comparison of numerical results is made with the earlier published results under limiting cases.

  19. Flow mechanism and heat transfer enhancement in longitudinal-flow tube bundle of shell-and-tube heat exchanger

    Institute of Scientific and Technical Information of China (English)

    LIU Wei; LIU ZhiChun; WANG YingShuang; HUANG SuYi

    2009-01-01

    ormer is superior to that of the latter.Compared with rod baffle heat exchanger,heat transfer coefficient of the heat exchanger under investigation is higher under same pressure drop,especially under the high Reynolds numbers.

  20. High-Speed Visual Analysis of Fluid Flow and Heat Transfer in Oscillating Heat Pipes with Different Diameters

    Directory of Open Access Journals (Sweden)

    Xiangdong Liu

    2016-10-01

    Full Text Available The oscillating heat pipe (OHP is a new member in the family of heat pipes, and it has great potential applications in energy conservation. However, the fluid flow and heat transfer in the OHP as well as the fundamental effects of inner diameter on them have not been fully understood, which are essential to the design and optimization of the OHP in real applications. Therefore, by combining the high-speed visualization method and infrared thermal imaging technique, the fluid flow and thermal performance in the OHPs with inner diameters of 1, 2 and 3 mm are presented and analyzed. The results indicate that three fluid flow motions, including small oscillation, bulk oscillation and circulation, coexist or, respectively, exist alone with the increasing heating load under different inner diameters, with three flow patterns occurring in the OHPs, viz. bubbly flow, slug flow and annular flow. These fluid flow motions are closely correlated with the heat and mass transfer performance in the OHPs, which can be reflected by the characteristics of infrared thermal images of condensers. The decrease in the inner diameter increases the frictional flow resistance and capillary instability while restricting the nucleate boiling in OHPs, which leads to a smaller proportion of bubbly flow, a larger proportion of short slug flow, a poorer thermal performance, and easier dry-out of working fluid. In addition, when compared with the 2 mm OHP, the increasing role of gravity induces the thermosyphon effect and weakens the ‘bubble pumping’ action, which results in a little smaller and bigger thermal resistances of 3 mm OHP under small and bulk oscillation of working fluid, respectively.

  1. Unsteady stagnation point flow and heat transfer over a stretching/shrinking sheet with prescribed surface heat flux

    Directory of Open Access Journals (Sweden)

    A. Ishak

    2012-08-01

    Full Text Available An analysis is carried out to study the unsteady two dimensional stagnation point flow and heat transfer over a stretching/shrinking sheet with prescribed surface heat flux. The governing partial differential equations are converted into nonlinear ordinary differential equations using similarity variables, and solved numerically. The effects of the unsteadiness parameter A, stretching/shrinking parameter ε and Prandtl number Pr on the flow and heat transfer characteristics are studied. It is found that the skin friction f′′(0 and the local Nusselt number 1θ(0 increase as the the unsteadiness parameter A increases. Moreover, the velocity and temperature increase as ε and Pr increase.

  2. Analysis of heat-flow data: detailed observations in many holes in a small area

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, T.J. (Dept. of Energy, Mines, and Resources, Ottawa); Beck, A.E.

    1977-08-03

    Terrestrial heat-flow measurements were made in 71 boreholes distributed over 5 km/sup 2/ near Noranda, Quebec. In nearly 50 percent of the boreholes there was some evidence of water flow along part of their total depth. Across the area the heat-flow values, uncorrected for climatic variation effects, vary systematically from 23 to 36 mW m/sup 2/ (0.55 to 0.85 ..mu..cal cm/sup -2/ s/sup -1/). Direct water flow along sections of boreholes cannot account for the heat-flow variation; a system maintained for a few thousand years, in which small quantities of water migrate from the surface down through the volcanic flow contacts and faults under the area of reduced heat flow, can account for the variation.

  3. Heat transfer and flow resistance performance of shutter baffle heat exchanger with triangle tube layout in shell side

    Directory of Open Access Journals (Sweden)

    Xin Gu

    2016-03-01

    Full Text Available Effect of main structural parameters of shutter baffle heat exchanger with a triangle tube layout in the shell side on heat transfer and flow resistance performance is studied in the article. A periodic whole cross-sectional computation model is built for the heat exchanger in the numerical study. The effects of structural parameters are analyzed, including assembly mode of shutter baffles, shutter baffle pitch, strip inclination angles, and strip widths. The correctness and accuracy of numerical simulation method are confirmed with a laser Doppler velocimeter experiment. Based on the research results, correlations for heat transfer coefficient and pressure drop in shell side are presented. Using the field synergy principle, the heat transfer enhancement mechanisms of segmental baffle heat exchanger and shutter baffle heat exchanger in shell side are analyzed.

  4. Investigation of a low flow solar heating system for space heating and domestic hot water supply for Aidt Miljø A/S

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1997-01-01

    A low flow solar heating system for space heating and domestic hot water supply from Aidt Miljø A/Swas tested in a laboratory test facility.......A low flow solar heating system for space heating and domestic hot water supply from Aidt Miljø A/Swas tested in a laboratory test facility....

  5. Latent Heat Flow in Light Weight Roofs and its Influence on the Thermal Performance

    DEFF Research Database (Denmark)

    Rode, Carsten; Rudbeck, Claus Christian

    1998-01-01

    on a colder surface. In these cases, themagnitude of the latent heat flux can be of the same order as the heat transfer by conduction. The latent heat transfer may result in a heat gain which coincides with other gains of an occupied building, and thus can cause an extra requirement for cooling. The paper...... reviews and quantifies the importance of heat flow processes in moist insulation systems. It then employs modeling to analyze the effect of extra heat gain caused bylatent heat transfer in the envelope on the thermal load on an office building chosen asan example. An extra cooling requirement of 6......Under certain conditions, migration of small amounts of moisture in the envelope of buildings can cause heat flow through permeable thermal insulation materials due to the conversion of latent heat when moisture evaporates from a warm surface, diffuses through the insulation, and condenses...

  6. Latent Heat Flow in Light Weight Roofs and its Influence on the Thermal Performance

    DEFF Research Database (Denmark)

    Rode, Carsten; Rudbeck, Claus Christian

    1998-01-01

    Under certain conditions, migration of small amounts of moisture in the envelope of buildings can cause heat flow through permeable thermal insulation materials due to the conversion of latent heat when moisture evaporates from a warm surface, diffuses through the insulation, and condenses...... reviews and quantifies the importance of heat flow processes in moist insulation systems. It then employs modeling to analyze the effect of extra heat gain caused bylatent heat transfer in the envelope on the thermal load on an office building chosen asan example. An extra cooling requirement of 6...... on a colder surface. In these cases, themagnitude of the latent heat flux can be of the same order as the heat transfer by conduction. The latent heat transfer may result in a heat gain which coincides with other gains of an occupied building, and thus can cause an extra requirement for cooling. The paper...

  7. Oesophageal heat transfer properties indication of segmental blood flow changes during distension

    DEFF Research Database (Denmark)

    Liao, Donghua; Frøkjær, Jens Brøndum; Brock, Christina

    2008-01-01

    on measurement of heat transfer. A bag was distended in the distal oesophagus of six healthy subjects followed by cooling or heating of the bag fluid to 5 or 60 degrees C. After equilibrium, the temperature was allowed to change back to body temperature. The temperature was recorded together with intraluminal...... ultrasound imaging, allowing assessment of the heat transfer properties at different bag volumes. The heat transfer constants were higher after heating the bag than after cooling the bag (Tukey, P heat transfer constants after heating the bag decreased as function of bag volumes whereas the heat...... transfer during cooling was not affected by the bag volume (F = 0.9, P = 0.4). The findings indicate that segmental blood flow can be assessed indirectly by calculating the heat transfer properties. Distension induced a drop in regional blood flow. Hence, ischaemia may contribute to distension-induced pain...

  8. Fractal density and singularity analysis of heat flow over ocean ridges

    Science.gov (United States)

    Qiuming, Cheng

    2016-01-01

    Peak heat flow occurs at mid-ocean ridges and decreases with the age of the oceanic lithosphere. Several plate models, including the Parsons and Sclater (PSM) model, Global Depth and Heat (GDH1) model and Constant Heat flow Applied on the Bottom Lithospheric Isotherm (CHABLIS) model, have been used to predict heat flow in the ocean lithosphere. The discrepancy between the predicted and measured heat flow in the younger lithosphere (i.e. younger than 55 Myr) influenced by local hydrothermal circulation has been used to estimate hydrothermal heat flux and investigate hydrothermal processes. We can modify the cooling models by substituting the ordinary mass density of lithosphere by fractal density with singularity. This new model provides a modified solution to fit the observed heat flow data used in other models in the literature throughout the age range. This model significantly improves the results for prediction of heat flow that were obtained using the PSM, GDH1 and CHABLIS models. Furthermore, the heat flow model does not exhibit special characteristics around any particular age of lithosphere. This raises a fundamental question about the existence of a “sealing” age and accordingly the hydrothermal flux estimation based on the cooling models.

  9. Fractal density and singularity analysis of heat flow over ocean ridges.

    Science.gov (United States)

    Qiuming, Cheng

    2016-01-13

    Peak heat flow occurs at mid-ocean ridges and decreases with the age of the oceanic lithosphere. Several plate models, including the Parsons and Sclater (PSM) model, Global Depth and Heat (GDH1) model and Constant Heat flow Applied on the Bottom Lithospheric Isotherm (CHABLIS) model, have been used to predict heat flow in the ocean lithosphere. The discrepancy between the predicted and measured heat flow in the younger lithosphere (i.e. younger than 55 Myr) influenced by local hydrothermal circulation has been used to estimate hydrothermal heat flux and investigate hydrothermal processes. We can modify the cooling models by substituting the ordinary mass density of lithosphere by fractal density with singularity. This new model provides a modified solution to fit the observed heat flow data used in other models in the literature throughout the age range. This model significantly improves the results for prediction of heat flow that were obtained using the PSM, GDH1 and CHABLIS models. Furthermore, the heat flow model does not exhibit special characteristics around any particular age of lithosphere. This raises a fundamental question about the existence of a "sealing" age and accordingly the hydrothermal flux estimation based on the cooling models.

  10. Advective and Conductive Heat Flow Budget Across the Wagner Basin, Northern Gulf of California

    Science.gov (United States)

    Neumann, F.; Negrete-Aranda, R.; Contreras, J.; Müller, C.; Hutnak, M.; Gonzalez-Fernandez, A.; Harris, R. N.; Sclater, J. G.

    2015-12-01

    In May 2015, we conducted a cruise across the northern Gulf of California, an area of continental rift basin formation and rapid deposition of sediments. The cruise was undertaken aboard the R/V Alpha Helix; our goal was to study variation in superficial conductive heat flow, lateral changes in the shallow thermal conductivity structure, and advective transport of heat across the Wagner basin. We used a Fielax heat flow probe with 22 thermistors that can penetrate up to 6 m into the sediment cover. The resulting data set includes 53 new heat flow measurements collected along three profiles. The longest profile (42 km) contains 30 measurements spaced 1-2 km apart. The western part of the Wagner basin (hanging wall block) exhibit low to normal conductive heat flow whereas the eastern part of the basin (foot wall block) heat flow is high to very high (up to 2500 mWm-2). Two other short profiles (12 km long each) focused on resolving an extremely high heat flow anomaly up to 15 Wm-2 located near the intersection between the Wagner bounding fault system and the Cerro Prieto fault. We hypothesize that the contrasting heat flow values observed across the Wagner basin are due to horizontal water circulation through sand layers and fault pathways of high permeability. Circulation appears to be from west (recharge zone) to east (discharge zone). Additionally, our results reveal strong vertical advection of heat due to dehydration reactions and compaction of fine grained sediments.

  11. Tectonic heat flow modelling for basin maturation - Implications for frontier areas in the mediterranean

    NARCIS (Netherlands)

    Wees, J.D. van; Bonte, D.; Nelskamp, S.

    2009-01-01

    Basement heat flow is one of the most influential parameters on basin maturity. Although rapid progress has been made in the development of tectonic models capable of modelling the thermal consequences of basin formation, these models are hardly used in basin modelling. To better predict heat flows

  12. Probabilistic tectonic heat flow modeling for basin maturation: Assessment method and applications

    NARCIS (Netherlands)

    Wees, J.D. van; Bergen, F. van; David, P.; Nepveu, M.; Beekman, F.; Cloetingh, S.; Bonté, D.

    2009-01-01

    Tectonic modeling is often neglected in the basin modeling workflow and heat flow is most times considered a user input. Such heat flows can, therefore, result in erroneous basin modeling outcomes, resulting in false overoptimistic identification of prospective areas or failure to identify prospects

  13. Numerical simulation of boundary heat flow effects on directional solidification microstructure of a binary alloy

    Directory of Open Access Journals (Sweden)

    Xue Xiang

    2010-08-01

    Full Text Available The boundary heat flow has important significance for the microstructures of directional solidified binary alloy. Interface evolution of the directional solidified microstructure with different boundary heat flow was discussed. In this study, only one interface was allowed to have heat flow, and Neumann boundary conditions were imposed at the other three interfaces. From the calculated results, it was found that different boundary heat flows will result in different microstructures. When the boundary heat flow equals to 20 W·cm-2, the growth of longitudinal side branches is accelerated and the growth of transverse side branches is restrained, and meanwhile, there is dendritic remelting in the calculation domain. When the boundary heat flow equals to 40 W·cm-2, the growths of the transverse and longitudinal side branches compete with each other, and when the boundary heat flow equals to 100-200 W·cm-2, the growth of transverse side branches dominates absolutely. The temperature field of dendritic growth was analyzed and the relation between boundary heat flow and temperature field was also investigated.

  14. Probabilistic tectonic heat flow modeling for basin maturation: Assessment method and applications

    NARCIS (Netherlands)

    Wees, J.D. van; Bergen, F. van; David, P.; Nepveu, M.; Beekman, F.; Cloetingh, S.; Bonté, D.

    2009-01-01

    Tectonic modeling is often neglected in the basin modeling workflow and heat flow is most times considered a user input. Such heat flows can, therefore, result in erroneous basin modeling outcomes, resulting in false overoptimistic identification of prospective areas or failure to identify

  15. Numerical simulation of boundary heat flow effects on directional solidification microstructure of a binary alloy

    Institute of Scientific and Technical Information of China (English)

    Xue Xiang; Tang Jinjun

    2010-01-01

    The boundary heat flow has important significance for the microstructures of directional solidified binary alloy. Interface evolution of the directional solidified microstructure with different boundary heat flow was discussed. In this study, only one interface was allowed to have heat flow, and Neumann boundary conditions were imposed at the other three interfaces. From the calculated results, it was found that different boundary heat flows will result in different microstructures. When the boundary heat flow equals to 20 W-cm-2, the growth of longitudinal side branches is accelerated and the growth of transverse side branches is restrained, and meanwhile, there is dendritic remelting in the calculation domain. When the boundary heat flow equals to 40 W-cm-2, the growths of the transverse and longitudinal side branches compete with each other, and when the boundary heat flow equals to 100-200 W-cm-2, the growth of transverse side branches dominates absolutely. The temperature field of dendritic growth was analyzed and the relation between boundary heat flow and temperature field was also investigated.

  16. Effect of flow maldistribution and axial conduction on compact microchannel heat exchanger

    Science.gov (United States)

    Baek, Seungwhan; Lee, Cheonkyu; Jeong, Sangkwon

    2014-03-01

    When a compact microchannel heat exchanger is operated at cryogenic environments, it has potential problems of axial conduction and flow maldistribution. To analyze these detrimental effects, the heat exchanger model that includes both axial conduction and flow maldistribution effect is developed in consideration of the microchannel heat exchanger geometry. A dimensionless axial conduction parameter (λ) is used to describe the axial conduction effect, and the coefficient of variation (CoV) is introduced to quantify the flow maldistribution condition. The effectiveness of heat exchanger is calculated according to the various values of the axial conduction parameter and the CoV. The analysis results show that the heat exchanger effectiveness is insensitive when λ is less than 0.005, and effectiveness is degraded with the large value of CoV. Three microchannel heat exchangers are fabricated with printed circuit heat exchanger (PCHE) technology for validation purpose of the heat exchanger model. The first heat exchanger is a conventional heat exchanger, the second heat exchanger has the modified cross section to eliminate axial conduction effect, and the third heat exchanger has the modified cross section and the cross link in parallel channel to mitigate flow maldistribution effect. These heat exchangers are tested in cryogenic single-phase, and two-phase environments. The third heat exchanger shows the ideal thermal characteristic, while the other two heat exchangers experience some performance degradation due to axial conduction or flow maldistribution. The impact of axial conduction and flow maldistribution effects are verified by the simulation results and compared with the experimental results.

  17. Monte Carlo simulations of dense gas flow and heat transfer in micro- and nano-channels

    Institute of Scientific and Technical Information of China (English)

    WANG Moran; LI Zhixin

    2005-01-01

    The dense gas flow and heat transfer in micro- and nano-channels was simulated using the Enskog simulation Monte Carlo (ESMC) method. The results were compared with those from the direct simulation Monte Carlo (DSMC) method and from the consistent Boltzmann algorithm (CBA). The dense gas flow and heat transfer characteristics were thus analyzed. The results showed that when the gas density was large enough, the finite gas density effect on the flow and heat transfer cannot be ignored, which decreased the skin friction coefficient and changed the heat transfer characteristics on the channel wall surfaces.

  18. CONJUGATE MODEL FOR HEAT AND MASS TRANSFER OF POROUS WALL IN THE HIGH TEMPERATURE GAS FLOW

    Institute of Scientific and Technical Information of China (English)

    A.F. Polyakov; D.L.Reviznikov; 沈青; 魏叔如

    2001-01-01

    Heat and mass transfer of a porous permeable wall in a high temperature gas dynamical flow is considered. Numerical simulation is conducted on the ground of the conjugate mathematical model which includes filtration and heat transfer equations in a porous body and boundary layer equations on its surface. Such an approach enables one to take into account complex interaction between heat and mass transfer in the gasdynamical flow and in the structure subjected to this flow.The main attention is given to the impact of the intraporous heat transfer intensity on the transpiration cooling efficiency.

  19. Comparison of heat transfer in straight and corrugated minichannels with two-phase flow

    Directory of Open Access Journals (Sweden)

    Peukert P.

    2014-03-01

    Full Text Available Measurements of heat transfer rates performed with an experimental condensation heat exchanger are reported for a corrugated minichannel tube and for a straight minichannel tube. The two cases were compared at same flow regimes. The corrugation appears advantageous for relatively low steam pressures and flow rates where much higher heat transfer rates were observed close to the steam entrance, thus allowing shortening the heat exchanger with the associated advantages of costs lowering and smaller built-up space. At high steam pressures and high flow rates both tubes performed similarly.

  20. Steady and transient forced convection heat transfer for water flowing in small tubes with exponentially increasing heat inputs

    Science.gov (United States)

    Shibahara, M.; Fukuda, K.; Liu, Q. S.; Hata, K.

    2017-03-01

    Steady and transient heat transfer coefficients for water flowing in small tubes with exponentially increasing heat inputs were measured. Platinum tubes with inner diameters of 1.0 and 2.0 mm were used as test tubes, which were mounted vertically in the experimental water loop. In the experiment, the upward flow velocity ranged from 2 to 16 m/s, and the corresponding Reynolds numbers ranged from 4.77 × 103 to 9.16 × 104 at the inlet liquid temperatures ranged from 298 to 343 K. The heat generation rate exponentially increased with the function. The period of the heat generation rate ranged from 24 ms to 17.5 s. Experimental results indicate that steady heat transfer coefficients decreased with the increase in the inner diameter of the small tube. Moreover, the ratio of bulk viscosity to near-wall viscosity of water increased with the rise in surface temperature of the vertical tube. From the experimental data, correlations of steady-state heat transfer for inner diameters of 1.0 and 2.0 mm were obtained. The heat transfer coefficient increased with decreasing the period of the heat generation rate as the flow velocity decreased. Moreover, the Nusselt number under the transient condition was affected by the Fourier number and the Reynolds number.

  1. Steady and transient forced convection heat transfer for water flowing in small tubes with exponentially increasing heat inputs

    Science.gov (United States)

    Shibahara, M.; Fukuda, K.; Liu, Q. S.; Hata, K.

    2016-06-01

    Steady and transient heat transfer coefficients for water flowing in small tubes with exponentially increasing heat inputs were measured. Platinum tubes with inner diameters of 1.0 and 2.0 mm were used as test tubes, which were mounted vertically in the experimental water loop. In the experiment, the upward flow velocity ranged from 2 to 16 m/s, and the corresponding Reynolds numbers ranged from 4.77 × 103 to 9.16 × 104 at the inlet liquid temperatures ranged from 298 to 343 K. The heat generation rate exponentially increased with the function. The period of the heat generation rate ranged from 24 ms to 17.5 s. Experimental results indicate that steady heat transfer coefficients decreased with the increase in the inner diameter of the small tube. Moreover, the ratio of bulk viscosity to near-wall viscosity of water increased with the rise in surface temperature of the vertical tube. From the experimental data, correlations of steady-state heat transfer for inner diameters of 1.0 and 2.0 mm were obtained. The heat transfer coefficient increased with decreasing the period of the heat generation rate as the flow velocity decreased. Moreover, the Nusselt number under the transient condition was affected by the Fourier number and the Reynolds number.

  2. Convection heat transfer and pressure drop in cross flow over finned tubes

    Energy Technology Data Exchange (ETDEWEB)

    Baran, M.; Pronobis, M.

    1984-05-15

    This paper reports the results of an experimental study on the heat transfer and pressure drop in finned tube banks. The measurements were carried out for the tubes with fins arranged parallel and a certain angle to the flow direction. The performance of such a heat exchanger with that of the conventional one i.e. plain tube heat exchanger, is compared.

  3. Melting Heat Transfer Characteristics of Latent Heat Microcapsule-Water Mixed Slurry Flowing in a Pipe with Constant Wall Heat Flux (Experimental Study)

    Science.gov (United States)

    Inaba, Hideo; Kim, Myoung-Jun; Horibe, Akihiko

    The present experiments have been performed for obtaining the melting heat transfer characteristics of micro-encapsulated solid-liquid phase change material and water mixed slurry flow in a circular tube heated with constant wall heat flux. The phase change material having a low melting point was selected for a domestic cooling system in the present study. The governing parameters were found to be latent heat material concentration,heat,flux,and the slurry velocity. The experimental results revealed that the mean heat transfer coefficient of latent microcapsule slurry was about l.3~l.8 times greater than that of the single phase of water. Moreover the effectiveness of heat transfer coefficient to friction factor had a maximum at latent heat material concentration of 25%.

  4. Flow-Induced Deformation of a Flexible Thin Structure as Manifestation of Heat Transfer Enhancement

    CERN Document Server

    Soti, Atul Kumar; Sheridan, John

    2015-01-01

    Flow-induced deformation of thin structures coupled with convective heat transfer has potential applications in energy harvesting and is important for understanding functioning of several biological systems. We numerically demonstrate large-scale flow-induced deformation as an effective passive heat transfer enhancement technique. An in-house, strongly-coupled fluid-structure interaction (FSI) solver is employed in which flow and structure solvers are based on sharp-interface immersed boundary and finite element method, respectively. In the present work, we validate convective heat transfer module of the in-house FSI solver against several benchmark examples of conduction and convective heat transfer including moving structure boundaries. The thermal augmentation is investigated as well as quantified for the flow-induced deformation of an elastic thin plate attached to lee side of a rigid cylinder in a heated channel laminar flow. We show that the wake vortices past the plate sweep higher sources of vorticity...

  5. Enhancing flow boiling heat transfer in microchannels for thermal management with monolithically-integrated silicon nanowires.

    Science.gov (United States)

    Li, D; Wu, G S; Wang, W; Wang, Y D; Liu, Dong; Zhang, D C; Chen, Y F; Peterson, G P; Yang, Ronggui

    2012-07-11

    Thermal management has become a critical issue for high heat flux electronics and energy systems. Integrated two-phase microchannel liquid-cooling technology has been envisioned as a promising solution, but with great challenges in flow instability. In this work, silicon nanowires were synthesized in situ in parallel silicon microchannel arrays for the first time to suppress the flow instability and to augment flow boiling heat transfer. Significant enhancement in flow boiling heat transfer performance was demonstrated for the nanowire-coated microchannel heat sink, such as an early onset of nucleate boiling, a delayed onset of flow oscillation, suppressed oscillating amplitudes of temperature and pressure drop, and an increased heat transfer coefficient.

  6. Numerical analysis of the steam flow field in shell and tube heat exchanger

    Directory of Open Access Journals (Sweden)

    Bartoszewicz Jarosław

    2016-06-01

    Full Text Available In the paper, the results of numerical simulations of the steam flow in a shell and tube heat exchanger are presented. The efficiency of different models of turbulence was tested. In numerical calculations the following turbulence models were used: k-ε, RNG k-ε, Wilcox k-ω, Chen-Kim k-ε, and Lam-Bremhorst k-ε. Numerical analysis of the steam flow was carried out assuming that the flow at the inlet section of the heat exchanger were divided into three parts. The angle of steam flow at inlet section was determined individually in order to obtain the best configuration of entry vanes and hence improve the heat exchanger construction. Results of numerical studies were verified experimentally for a real heat exchanger. The modification of the inlet flow direction according to theoretical considerations causes the increase of thermal power of a heat exchanger of about 14%.

  7. Numerical analysis of the steam flow field in shell and tube heat exchanger

    Science.gov (United States)

    Bartoszewicz, Jarosław; Bogusławski, Leon

    2016-06-01

    In the paper, the results of numerical simulations of the steam flow in a shell and tube heat exchanger are presented. The efficiency of different models of turbulence was tested. In numerical calculations the following turbulence models were used: k-ɛ, RNG k-ɛ, Wilcox k-ω, Chen-Kim k-ɛ, and Lam-Bremhorst k-ɛ. Numerical analysis of the steam flow was carried out assuming that the flow at the inlet section of the heat exchanger were divided into three parts. The angle of steam flow at inlet section was determined individually in order to obtain the best configuration of entry vanes and hence improve the heat exchanger construction. Results of numerical studies were verified experimentally for a real heat exchanger. The modification of the inlet flow direction according to theoretical considerations causes the increase of thermal power of a heat exchanger of about 14%.

  8. Heat transfer and fluid flow in biological processes advances and applications

    CERN Document Server

    Becker, Sid

    2015-01-01

    Heat Transfer and Fluid Flow in Biological Processes covers emerging areas in fluid flow and heat transfer relevant to biosystems and medical technology. This book uses an interdisciplinary approach to provide a comprehensive prospective on biofluid mechanics and heat transfer advances and includes reviews of the most recent methods in modeling of flows in biological media, such as CFD. Written by internationally recognized researchers in the field, each chapter provides a strong introductory section that is useful to both readers currently in the field and readers interested in learning more about these areas. Heat Transfer and Fluid Flow in Biological Processes is an indispensable reference for professors, graduate students, professionals, and clinical researchers in the fields of biology, biomedical engineering, chemistry and medicine working on applications of fluid flow, heat transfer, and transport phenomena in biomedical technology. Provides a wide range of biological and clinical applications of fluid...

  9. In-situ shear stress indicator using heated strain gages at the flow boundary

    Science.gov (United States)

    Yeh, Chi-An; Yang, Fuling

    2011-11-01

    This work borrows the concept of hot-wire anemometry and sketch a technique that uses local heat transfer to infer the flow field and the corresponding stress. Conventional strain gages were mounted at the flow solid boundary as the heat source and acrylic boundary was chosen for its low thermal conductivity ensuring heat accumulation when a gage is energized. The gage would now work in slightly overheated state and its self-heating leads to an additional thermal strain. When exposed to a flow field, heat is brought away by local forced convection, resulting in deviations in gage signal from that developed in quiescent liquid. We have developed a facility to achieve synchronous gage measurements at different locations on a solid boundary. Three steady flow motions were considered: circular Couette flow, rectilinear uniform flow, and rectilinear oscillating flow. Preliminary tests show the gage reading does respond to the imposed flow through thermal effects and greater deviation was measured in flows of higher shear strain rates. The correlation between the gage signals and the imposed flow field is further examined by theoretical analysis. We also introduced a second solid boundary to the vicinity of the gage in the two rectilinear flows. The gage readings demonstrate rises in its magnitudes indicating wall amplification effect on the local shear strain, agreeing to the drag augmentation by a second solid boundary reported in many multiphase flow literatures.

  10. Thermal design of multi-fluid mixed-mixed cross-flow heat exchangers

    Science.gov (United States)

    Roetzel, W.; Luo, X.

    2010-11-01

    A fast analytical calculation method is developed for the thermal design and rating of multi-fluid mixed-mixed cross-flow heat exchangers. Temperature dependent heat capacities and heat transfer coefficients can iteratively be taken into account. They are determined at one or two special reference temperatures. Examples are given for the application of the method to the rating of special multi-fluid multi-pass shell-and-tube heat exchangers and multi-fluid cross-flow plate-fin heat exchangers. The accuracy of the method is tested against numerical calculations with good results.

  11. A simple and accurate numerical network flow model for bionic micro heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Pieper, M.; Klein, P. [Fraunhofer Institute (ITWM), Kaiserslautern (Germany)

    2011-05-15

    Heat exchangers are often associated with drawbacks like a large pressure drop or a non-uniform flow distribution. Recent research shows that bionic structures can provide possible improvements. We considered a set of such structures that were designed with M. Hermann's FracTherm {sup registered} algorithm. In order to optimize and compare them with conventional heat exchangers, we developed a numerical method to determine their performance. We simulated the flow in the heat exchanger applying a network model and coupled these results with a finite volume method to determine the heat distribution in the heat exchanger. (orig.)

  12. A study of sensing heat flow through thermal walls by using thermoelectric module

    OpenAIRE

    Sippawit Noppawit; Leephakpreeda Thananchai

    2015-01-01

    Demands on heat flow detection at a plane wall via a thermoelectric module have drawn researchers’ attention to quantitative understanding in order to properly implement the thermoelectric module in thermal engineering practices. Basic mathematical models of both heat transfer through a plane wall and thermoelectric effects are numerically solved to represent genuine behaviors of heat flow detection by mounting a thermoelectric module at a plane wall. The h...

  13. Rapid heat-flowing surveying of geothermal areas, utilizing individual snowfalls as calorimeters

    Science.gov (United States)

    White, Donald E.

    1969-01-01

    Local differences in rate of heat transfer in vapor and by conduction through the ground in hot spring areas are difficult and time-consuming to measure quantitatively. Individual heavy snowfalls provide a rapid low-cost means of measuring total heat flow from such ground. After a favorable snowfall (heavy, brief duration, little wind, air temperature near 0°C), contacts between snow-covered and snow-free ground are mapped on a suitable base. Each mapped contact, as time elapses after a specific snowfall, is a heat-flow contour representing a decreasing rate of flow. Calibration of each mapped contact or snow line is made possible by the fact that snow remains on insulated surfaces (such as the boardwalks of Yellowstone's thermal areas) long after it has melted on adjacent warm ground. Heat-flow contours mapped to date range from 450 to 5500 μcal/cm2 sec, or 300 to 3700 times the world average of conductive heat flow. The very high rates of heat flow (2000 to > 10,000 μcal/cm2 sec) are probably too high, and the lower heat flows determinable by the method (2 sec) may be too low. Values indicated by the method are, however, probably within a factor of 2 of the total conductive and convective heat flow. Thermal anomalies from infrared imagery are similar in shape to heat-flow contours of a test area near Old Faithful geyser. Snowfall calorimetry provides a rapid means for evaluating the imagery and computer-derived products of the infrared data in terms of heat flow.

  14. Simulation Studies on A Cross Flow Plate Fin Heat Exchanger

    OpenAIRE

    Thirumarimurugan, M.; Kannadasan, T.; E. Ramasamy

    2008-01-01

    Compact heat exchangers which were initially developed for the aerospace industries in the1940s have been considerably improved in the past few years. The main reasons for the goodperformance of compact heat exchangers are their special design which includes turbulent which inturn use high heat transfer coefficient and resists fouling, and maximum temperature driving forcebetween the hot and cold fluids. Numerous types use special enhancement techniques to achieve therequired heat transfer in...

  15. Analysis of Tube Bank Heat Transfer In Downward Directed Foam Flow

    Directory of Open Access Journals (Sweden)

    Jonas Gylys

    2004-06-01

    Full Text Available Apparatus with the foam flow are suitable to use in different technologies like heat exchangers, food industry, chemical and oil processing industry. Statically stable liquid foam until now is used in technologic systems rather seldom. Although a usage of this type of foam as heat transfer agent in foam equipment has a number of advantages in comparison with one phase liquid equipment: small quantity of liquid is required, heat transfer rate is rather high, mass of equipment is much smaller, energy consumption for foam delivery into heat transfer zone is lower. The paper analyzes the peculiarities of heat transfer from distributed in staggered order and perpendicular to foam flow in channel of rectangular cross section tube bundle to the foam flow. It was estimated the dependence of mean gas velocity and volumetric void fraction of foam flow to heat transfer in downward foam flow. Significant difference of heat transfer intensity from front and back tubes of tube row in laminar foam flow was noticed. Dependence of heat transfer on flow velocity and volumetric void fraction of foam was confirmed and estimated by criterion equations.

  16. Nanoscale Heat Transfer Due to Near Field Radiation and Nanofluidic Flows

    Science.gov (United States)

    2015-07-21

    AFRL-OSR-VA-TR-2015-0205 Nanoscale heat transfer due to near field radiation and nanofluidic flows Peter Taborek UNIVERSITY OF CALIFORNIA IRVINE...TITLE AND SUBTITLE Nanoscale heat transfer due to near field radiation and nanofluidic flows 5a. CONTRACT NUMBER 5b. GRANT NUMBER FA9550-12-1-0065...liquid flows through the pipe would spontaneously form a liquid/vapor interface either inside the pie or near the exit. We developed a model which

  17. Skin and muscle components of forearm blood flow in directly heated resting man.

    Science.gov (United States)

    Detry, J.-M. R.; Brengelmann, G. L.; Rowell, L. B.; Wyss, C.

    1972-01-01

    Changes in forearm muscle blood flow (FMBF) during direct whole-body heating were measured in 17 normal subjects using three different methods. We conclude that FMBF is not increased by direct whole-body heating. Since renal and splanchnic blood flow fall 30% under these conditions, maximal total skin blood flow in 12 previously studied subjects can be estimated from the rise in cardiac output to be 7.6 L/min (3.0-11.1 L/min).

  18. Simulation of Rocket-Grade Kerosene Flowing in an Electrically Heated Experimental Apparatus

    Science.gov (United States)

    2015-07-01

    assessed by measuring the carbon deposit formation rate. The experiment is aimed at developing a new standardized thermal stability test. The rocket...the tube, thermally coupled with steady heat conduction , and electric current flow in the solid copper apparatus. Temperature dependence of fluid and...density turbulent flow inside the tube, thermally coupled with steady heat conduction , and electric current flow in the solid copper apparatus

  19. Heat transfer in boundary layer stagnation-point flow towards a shrinking sheet with non-uniform heat flux

    Institute of Scientific and Technical Information of China (English)

    Krishnendu Bhattacharyya

    2013-01-01

    In this paper,the effect of non-uniform heat flux on heat transfer in boundary layer stagnation-point flow over a shrinking sheet is studied.The variable boundary heat fluxes are considered of two types:direct power-law variation with the distance along the sheet and inverse power-law variation with the distance.The governing partial differential equations (PDEs) are transformed into non linear self-similar ordinary differential equations (ODEs) by similarity transformations,and then those are solved using very efficient shooting method.The direct variation and inverse variation of heat flux along the sheet have completely different effects on the temperature distribution.Moreover,the heat transfer characteristics in the presence of non-uniform heat flux for several values of physical parameters are also found to be interesting.

  20. Combined lock-in thermography and heat flow measurements for analysing heat dissipation during fatigue crack propagation

    Directory of Open Access Journals (Sweden)

    J. Bär

    2015-10-01

    Full Text Available During fatigue crack propagation experiments with constant force as well as constant stress intensity lock in thermography and heat flow measurements with a new developed peltier sensor have been performed. With lock in thermography space resolved measurements are possible and the evaluation allows to distinguish between elastic and dissipated energies. The specimens have to be coated with black paint to enhance the emissivity. The thickness of the coating influences the results and therefore quantitative measurements are problematic. The heat flow measurements are easy to perform and provide quantitative results but only integral in an area given by the used peltier element. To get comparable results the values measured with thermography were summarized in an area equivalent to that of the peltier element. The experiments with constant force show a good agreement between the thermography and the heat flow measurements. In case of the experiments with a constant stress intensity some differences become visible. Whereas the thermography measurements show a linear decrease of the signal with rising crack length, the heat flow measurements show a clearly nonlinear dependency. Obviously the measured energies in thermography and peltier based heat flow measurement are not comparable

  1. Two phase convective heat transfer augmentation in swirl flow with non-boiling

    Energy Technology Data Exchange (ETDEWEB)

    Cha, K.O. [Myong Ji University, Kyonggi-do (Korea, Republic of); Kim, J.G. [Myongji University Graduate School, Kyonggi-do (Korea, Republic of)

    1995-10-01

    Two phase flow phenomena are observed in many industrial facilities and make much importance of optimum design for nuclear power plant and various heat exchangers. This experimental study has been investigated the classification of the flow pattern, the local void distribution and convective heat transfer in swirl and non-swirl two phase flow under the isothermal and nonisothermal conditions. The convective heat transfer coefficients in the single phase water flow were measured and compared with the calculated results from the Sieder-Tate correlation. These coefficients were used for comparisons with the two-phase heat transfer coefficients in the flow orientations. The experimental results indicate, that the void probe signal and probability density function of void distribution can used into classify the flow patterns, no significant difference in voidage distribution was observed between isothermal and non-isothermal condition in non-swirl flow, the values of two phase heat transfer coefficients increase when superficial air velocities increase, and the enhancement of the values is observed to be most pronounced at the highest superficial water velocity in non-swirl flow. Also two phase heat transfer coefficients in swirl flow are increased when the twist ratios are decreased. (author). 13 refs., 15 figs.

  2. Crustal heat flow measurements in western Anatolia from borehole equilibrium temperatures

    Directory of Open Access Journals (Sweden)

    K. Erkan

    2014-01-01

    Full Text Available Results of a crustal heat flow analysis in western Anatolia based on borehole equilibrium temperatures and rock thermal conductivity data are reported. The dataset comprises 113 borehole sites that were collected in Southern Marmara and Aegean regions of Turkey in 1995–1999. The measurements are from abandoned water wells with depths of 100–150 m. Data were first classed in terms of quality, and the low quality data, including data showing effects of hydrologic disturbances on temperatures, were eliminated. For the remaining 34 sites, one meter resolution temperature-depth curves were carefully analyzed for determination of the background geothermal gradients, and any effects of terrain topography and intra-borehole fluid flow were corrected when necessary. Thermal conductivities were determined either by direct measurements on representative surface outcrop or estimated from the borehole lithologic records. The calculated heat flow values are 85–90 mW m−2 in the northern and central parts of the Menderes horst-graben system. Within the system, the highest heat flow values (> 100 mW m−2 are observed in the northeastern part of Gediz Graben, near Kula active volcanic center. The calculated heat flow values are also in agreement with the results of studies on the maximum depth of seismicity in the region. In the Menderes horst-graben system, surface heat flow is expected to show significant variations as a result of active sedimentation and thermal refraction in grabens, and active erosion on horst detachment zones. High heat flow values (90–100 mW m−2 are also observed in the peninsular (western part of Çanakkale province. The heat flow anomaly here may be an extension of the high heat flow zone previously observed in the northern Aegean Sea. Moderate heat flow values (60–70 mW m−2 are observed in eastern part of Çanakkale and central part of Balıkesir provinces.

  3. Analytical skin friction and heat transfer formula for compressible internal flows

    Science.gov (United States)

    Dechant, Lawrence J.; Tattar, Marc J.

    1994-01-01

    An analytic, closed-form friction formula for turbulent, internal, compressible, fully developed flow was derived by extending the incompressible law-of-the-wall relation to compressible cases. The model is capable of analyzing heat transfer as a function of constant surface temperatures and surface roughness as well as analyzing adiabatic conditions. The formula reduces to Prandtl's law of friction for adiabatic, smooth, axisymmetric flow. In addition, the formula reduces to the Colebrook equation for incompressible, adiabatic, axisymmetric flow with various roughnesses. Comparisons with available experiments show that the model averages roughly 12.5 percent error for adiabatic flow and 18.5 percent error for flow involving heat transfer.

  4. MHD Flow Towards a Permeable Surface with Prescribed Wall Heat Flux

    Institute of Scientific and Technical Information of China (English)

    Anuar Ishak; Roslinda Nazar; Ioan Pop

    2009-01-01

    The steady magnetohydrodynamic (MHD) mixed convection flow towards a vertical permeable surface with prescribed heat flux is investigated. The governing partial differential equations are transformed into a system of ordinary differential equations, which is then solved numerically by a finite-difference method. The features of the flow and heat transfer characteristics for different values of the governing parameters are analysed and discussed. Both assisting and opposing flows are considered. It is found that dual solutions exist for the assisting flow, besides the solutions usually reported in the literature for the opposing flow.

  5. Experimental Research on Flow Maldistribution in Plate-Fin Heat Exchangers

    Institute of Scientific and Technical Information of China (English)

    张哲; 厉彦忠; 许箐

    2004-01-01

    The flow maldistribution and the effect of different inlet configuration on the flow distribution in platefin heat exchangers were studied experimentally. It is found that the flow maldistribution is serious because of the defects of inlet configurations, while the inlet configuration and Reynolds number are the main factors affecting the flow distribution. The improved inlet configurations, which are the header with a two-stage distributing configuration and the guide vane with a fluid complementary cavity were proposed and tested in this paper. The experimental results show that the improved inlet configurations can effectively improve the performance of flow distribution in heat exchangers.

  6. Liquid-Vapor Flow Regime Transitions for Spacecraft Heat Transfer Loops

    Science.gov (United States)

    1988-12-01

    heavenly bodies, in spite of their astonishing distances, than in the investigations of the movement of flowing water before our very eyes" Galileo ... Galilei 1564-1642 Motivation to Study MicroQravity Flow Reuimes The study of microgravity vapor-liquid flow regimes is motivated by the benefits of heat

  7. Introduction of image analysis for the quantification of the boiling flow heat transfer

    NARCIS (Netherlands)

    Ferret, C.; Falk, L.; d'Ortona, U.; Chenu, A.; Veenstra, T.T.

    2004-01-01

    Heat transfer performances for non-boiling and boiling flow of a micro-vaporizer have been measured by standard methods (temperatures, flow rates, effective power input). The study was carried out for laminar flow (Re<25) in silicon micro-channels (5 mm×3 cm×200 μm) filled with ordered obstacles to

  8. Introduction of image analysis for the quantification of the boiling flow heat transfer

    NARCIS (Netherlands)

    Ferret, C.; Falk, L.; d'Ortona, U.; Chenu, A.; Veenstra, T.T.

    2004-01-01

    Heat transfer performances for non-boiling and boiling flow of a micro-vaporizer have been measured by standard methods (temperatures, flow rates, effective power input). The study was carried out for laminar flow (Re<25) in silicon micro-channels (5 mm×3 cm×200 μm) filled with ordered obstacles to

  9. Flow and Heat Transfer Characteristics in a Closed-Type Two-Phase Loop Thermosyphon

    Science.gov (United States)

    Imura, Hideaki; Saito, Yuji; Fujimoto, Hiromitsu

    A closed-loop two-phase thermosyphon can transport a large amount of thermal energy with small temperature differences without any external power supply. A fundamental investigation of flow and heat transfer characteristics was performed experimentally and theoretically using water, ethanol and R113 as the working liquids. Heat transfer coefficients in an evaporator and a condenser, and circulation flow rates were measured experimentally. The effects of liquid fill charge, rotation angle, pressure in the loop and heat flux on the heat transfer coefficients were examined. The heat transfer coefficients in the evaporator and the condenser were correlated by the expressions for pool boiling and film condensation respectively. As a result, the heat transfer coefficients in the evaporator were correlated by the Stephan-Abdelsalam equations within a±40% error. Theoretically, the circulation flow rate was predicted by calculating pressure, temperature, quality and void fraction along the loop. And, the comparison between the calculated and experimental results was made.

  10. Ice slurry flow and heat transfer during flow through tubes of rectangular and slit cross-sections

    Directory of Open Access Journals (Sweden)

    Niezgoda-Żelasko Beata

    2014-09-01

    Full Text Available The paper presents the results of experimental research of pressure drop and heat transfer coefficients of ice slurry during its flow through tubes of rectangular and slit cross-sections. Moreover, the work discusses the influence of solid particles, type of motion and cross-section on the changes in the pressure drop and heat transfer coefficient. The analysis presented in the paper allows for identification of the criterial relations used to calculate the Fanning factor and the Nusselt number for laminar and turbulent flow, taking into account elements such as phase change, which accompanies the heat transfer process. Ice slurry flow is treated as a generalized flow of a non-Newtonian fluid.

  11. Experimental investigation of flow and heat transfer characteristics of R-134a in microchannels

    Science.gov (United States)

    Hegab, Hisham E.; Bari, Abdullahel; Ameel, Timothy A.

    2001-09-01

    Fluid flow and heat transfer characteristics of single-phase flows in microchannels for refrigerant R-134a were experimentally investigated. Experiments were conducted using rectangular channels micro-milled in aluminum with hydraulic diameters ranging from approximately 112-mm to 210-mm and aspect ratios that varied from 1.0 to 1.5. Using overall temperature, flow rate, and pressure drop measurements, friction factors and convective heat transfer coefficients were experimentally determined for steady flow conditions. Reynolds number, relative roughness, and channel aspect ratio were the parameters examined in predicting friction factor and Nusselt number for the experiments. Experiment results indicated transition from laminar to turbulent flow occurred between a Reynolds number of 2,000-4,000. Friction factor results were consistently lower than values predicted by macroscale correlations. Nusselt number results indicated channel size may suppress turbulent convective heat transfer. Results also indicate that surface roughness may affect heat transfer characteristics in the turbulent regime.

  12. Heat Transfer Characteristics of Liquid-Gas Taylor Flows incorporating Microencapsulated Phase Change Materials

    Science.gov (United States)

    Howard, J. A.; Walsh, P. A.

    2014-07-01

    This paper presents an investigation on the heat transfer characteristics associated with liquid-gas Taylor flows in mini channels incorporating microencapsulated phase change materials (MPCM). Taylor flows have been shown to result in heat transfer enhancements due to the fluid recirculation experienced within liquid slugs which is attributable to the alternating liquid slug and gas bubble flow structure. Microencapsulated phase change materials (MPCM) also offer significant potential with increased thermal capacity due to the latent heat required to cause phase change. The primary aim of this work was to examine the overall heat transfer potential associated with combining these two novel liquid cooling technologies. By investigating the local heat transfer characteristics, the augmentation/degradation over single phase liquid cooling was quantified while examining the effects of dimensionless variables, including Reynolds number, liquid slug length and gas void fraction. An experimental test facility was developed which had a heated test section and allowed MPCM-air Taylor flows to be subjected to a constant heat flux boundary condition. Infrared thermography was used to record high resolution experimental wall temperature measurements and determine local heat transfer coefficients from the thermal entrance point. 30.2% mass particle concentration of the MPCM suspension fluid was examined as it provided the maximum latent heat for absorption. Results demonstrate a significant reduction in experimental wall temperatures associated with MPCM-air Taylor flows when compared with the Graetz solution for conventional single phase coolants. Total enhancement in the thermally developed region is observed to be a combination of the individual contributions due to recirculation within the liquid slugs and also absorption of latent heat. Overall, the study highlights the potential heat transfer enhancements that are attainable within heat exchange devices employing MPCM

  13. The first deep heat flow determination in crystalline basement rocks beneath the Western Canadian Sedimentary Basin

    Science.gov (United States)

    Majorowicz, Jacek; Chan, Judith; Crowell, James; Gosnold, Will; Heaman, Larry M.; Kück, Jochem; Nieuwenhuis, Greg; Schmitt, Douglas R.; Unsworth, Martyn; Walsh, Nathaniel; Weides, Simon

    2014-05-01

    Heat flow (Q) determined from bottom-hole temperatures measured in oil and gas wells in Alberta show a large scatter with values ranging from 40 to 90 mW m-2. Only two precise measurements of heat flow were previously reported in Alberta, and were made more than half a century ago. These were made in wells located near Edmonton, Alberta, and penetrated the upper kilometre of clastic sedimentary rocks yielding heat flows values of 61 and 67 mW m-2 (Garland & Lennox). Here, we report a new precise heat flow determination from a 2363-m deep well drilled into basement granite rocks just west of Fort McMurray, Alberta (the Hunt Well). Temperature logs acquired in 2010-2011 show a significant increase in the thermal gradient in the granite due to palaeoclimatic effects. In the case of the Hunt Well, heat flow at depths >2200 m is beyond the influence of the glacial-interglacial surface temperatures. Thermal conductivity and temperature measurements in the Hunt Well have shown that the heat flow below 2.2 km is 51 mW m-2 (±3 mW m-2), thermal conductivity measured by the divided bar method under bottom of the well in situ like condition is 2.5 W m-1 K-1, and 2.7 W m-1 K-1 in ambient conditions), and the geothermal gradient was measured as 20.4 mK m-1. The palaeoclimatic effect causes an underestimate of heat flow derived from measurements collected at depths shallower than 2200 m, meaning other heat flow estimates calculated from basin measurements have likely been underestimated. Heat production (A) was calculated from spectral gamma recorded in the Hunt Well granites to a depth of 1880 m and give an average A of 3.4 and 2.9 μW m-3 for the whole depth range of granites down to 2263 m, based on both gamma and spectral logs. This high A explains the relatively high heat flow measured within the Precambrian basement intersected by the Hunt Well; the Taltson Magmatic Zone. Heat flow and related heat generation from the Hunt Well fits the heat flow-heat generation

  14. Numerical Study of Laminar Flow and Convective Heat Transfer Utilizing Nanofluids in Equilateral Triangular Ducts with Constant Heat Flux

    Directory of Open Access Journals (Sweden)

    Hsien-Hung Ting

    2016-07-01

    Full Text Available This study numerically investigates heat transfer augmentation using water-based Al2O3 and CuO nanofluids flowing in a triangular cross-sectional duct under constant heat flux in laminar flow conditions. The Al2O3/water nanofluids with different volume fractions (0.1%, 0.5%, 1%, 1.5%, and 2% and CuO/water nanofluids with various volume fractions (0.05%, 0.16%, 0.36%, 0.5%, and 0.8% are employed, and Reynolds numbers in the range of 700 to 1900 in a laminar flow are considered. The heat transfer rate becomes more remarkable when employing nanofluids. As compared with pure water, at a Peclet number of 7000, a 35% enhancement in the convective heat transfer coefficient, is obtained for an Al2O3/water nanofluid with 2% particle volume fraction; at the same Peclet number, a 41% enhancement in the convective heat transfer coefficient is achieved for a CuO/water nanofluid with 0.8% particle volume concentration. Heat transfer enhancement increases with increases in particle volume concentration and Peclet number. Moreover, the numerical results are found to be in good agreement with published experimental data.

  15. Comparative study of Nusselt number for a single phase fluid flow using plate heat exchanger

    Directory of Open Access Journals (Sweden)

    Shanmugam Rajasekaran

    2016-01-01

    Full Text Available In this study, the plate heat exchangers are used for various applications in the industries for heat exchange process such as heating, cooling and condensation. The performance of plate heat exchanger depends on many factors such as flow arrangements, plate design, chevron angle, enlargement factor, type of fluid used, etc. The various Nusselt number correlations are developed by considering that the water as a working fluid. The main objective of the present work is to design the experimental set-up for a single phase fluid flow using plate heat exchanger and studied the heat transfer performance. The experiments are carried out for various Reynolds number between 500 and 2200, the heat transfer coefficients are estimated. Based on the experimental results the new correlation is developed for Nusselt number and compared with an existing correlation.

  16. Bypass valve and coolant flow controls for optimum temperatures in waste heat recovery systems

    Science.gov (United States)

    Meisner, Gregory P

    2013-10-08

    Implementing an optimized waste heat recovery system includes calculating a temperature and a rate of change in temperature of a heat exchanger of a waste heat recovery system, and predicting a temperature and a rate of change in temperature of a material flowing through a channel of the waste heat recovery system. Upon determining the rate of change in the temperature of the material is predicted to be higher than the rate of change in the temperature of the heat exchanger, the optimized waste heat recovery system calculates a valve position and timing for the channel that is configurable for achieving a rate of material flow that is determined to produce and maintain a defined threshold temperature of the heat exchanger, and actuates the valve according to the calculated valve position and calculated timing.

  17. Effects of Blood Flow on the Heating of Cardiac Stents Due to Radio Frequency Fields

    OpenAIRE

    Elder, Nate Ian

    2013-01-01

    A safety concern during MRI scans with implanted medical devices is heating induced by the incident RF field. This research was performed to better understand the heating of cardiac stents during MRI. Heating of cardiac stents tends to occur at their ends. The temperature rise will be affected by blood flow through the lumen of the stent. In this work, an experiment was performed to simulate heating of a cardiac stent in the presence of blood flow during exposure to the electric field induced...

  18. Heat Transfer from a dc Laminar Plasma-Jet Flow to Different Solid Surfaces

    Institute of Scientific and Technical Information of China (English)

    孟显; 潘文霞; 吴承康

    2003-01-01

    The heat flux distributions were measured by using transient method for an argon dc laminar plasma-jet flow impinging normally on a plate surface embedded with copper probes. Different powders were coated on the probe surfaces and the effect of powder coatings on the heat transfer from jet flow to the probe surface was examined.Experimental results show that the maximum values of the heat flux to the probe increase with the coating of fine metal powders, while for the surfaces coated with fine ceramic powders, the maximum values of heat flux decrease, compared with that to the bare copper probe surface.

  19. Numerical Solution of Heat Tranfer Problem with Flow and Solidification in Round Billet Continuous Casting of Steel

    Institute of Scientific and Technical Information of China (English)

    JiahongGUO; XinHong

    1999-01-01

    In this paper,two dimensional unsteady flow and energy equations are employed for simulation of the flow and heat transfer in round billet continuous casting A numerical method is developed,by using finite volume method and equivalent specific heat method to solve the equations of flow and heat transfer with solidification.The numerical result shows that the method of this paper is efficient for analyzing the flow and heat transfer with solidification of round billet continuous casting.

  20. Convective heat transfer characteristics of low Reynolds number nanofluid flow around a circular cylinder

    Directory of Open Access Journals (Sweden)

    Yacine Khelili

    2017-03-01

    Full Text Available Numerical investigation of heat transfer phenomena of low Reynolds number nano-fluid flow over an isothermal cylinder is presented in this paper. Steady state governing equations (continuity, N–S and energy equations have been solved using finite volume method. Stationary heat transfer, and flow characteristics over the cylinder have been studied for water based copper nanofluid with different solid fraction values. The effect of volume fraction of nano- particles on the fluid flow and heat transfer were investigated numerically. It was found that at a given Nusselt number, drag coefficient, re-circulation length, and pressure coefficient increase by increasing the volume fraction of nano-particles.

  1. A new approach for thermal performance calculation of cross-flow heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, H.A. [Universidade Estadual Paulista, Rio Claro (Brazil). Dpto. de Estatistica; Cabezas-Gomez, L. [Universidade de Sao Paulo, Sao Carlos (Brazil). Dpto. de Engenharia Mecanica

    2005-08-01

    A new numerical methodology for thermal performance calculation in cross-flow heat exchangers is developed. Effectiveness-number of transfer units ({epsilon}-NTU) data for several standard and complex flow arrangements are obtained using this methodology. The results are validated through comparison with analytical solutions for one-pass cross-flow heat exchangers with one to four rows and with approximate series solution for an unmixed-unmixed heat exchanger, obtaining in all cases very small errors. New effectiveness data for some complex configurations are provided. (author)

  2. ON THE HEAT FLOW EQUATION OF SURFACES OF CONSTANT MEAN CURVATURE IN HIGHER DIMENSIONS

    Institute of Scientific and Technical Information of China (English)

    Tan Zhong; Wu Guochun

    2011-01-01

    In this paper,we consider the heat flow for the H-system with constant mean curvature in higher dimensions.We give sufficient conditions on the initial data such that the heat flow develops finite time singularity.We also provide a new set of initial data to guarantee the existence of global regular solution to the heat flow,that converges to zero in W1,n with the decay rate t2/2-n as time goes to infinity.

  3. Effects of mass flow rate and droplet velocity on surface heat flux during cryogen spray cooling

    Energy Technology Data Exchange (ETDEWEB)

    Karapetian, Emil [Department of Chemical Engineering and Material Sciences, University of California, Irvine, CA (United States); Aguilar, Guillermo [Department of Biomedical Engineering, University of California, Irvine, CA (United States); Kimel, Sol [Beckman Laser Institute, University of California, Irvine, CA (United States); Lavernia, Enrique J [Department of Chemical Engineering and Material Sciences, University of California, Irvine, CA (United States); Nelson, J Stuart [Department of Biomedical Engineering, University of California, Irvine, CA (United States)

    2003-01-07

    Cryogen spray cooling (CSC) is used to protect the epidermis during dermatologic laser surgery. To date, the relative influence of the fundamental spray parameters on surface cooling remains incompletely understood. This study explores the effects of mass flow rate and average droplet velocity on the surface heat flux during CSC. It is shown that the effect of mass flow rate on the surface heat flux is much more important compared to that of droplet velocity. However, for fully atomized sprays with small flow rates, droplet velocity can make a substantial difference in the surface heat flux. (note)

  4. Understanding heat transfer in 2D channel flows including recirculation

    NARCIS (Netherlands)

    Dirkse, M.H.; Loon, van W.K.P.; Stigter, J.D.; Bot, G.P.A.

    2007-01-01

    Inviscid, irrotational two-dimensional flows can be modelled using the Schwarz¿Christoffel integral. Although bounded flows including boundary layer separation and recirculation are not irrotational, a model is presented that uses the Schwarz¿Christoffel integral to model these flows. The model sepa

  5. On the Uniqueness of Heat Flow of Harmonic Maps and Hydrodynamic Flow of Nematic Liquid Crystals

    Institute of Scientific and Technical Information of China (English)

    Fanghua LIN; Changyou WANG

    2010-01-01

    For any n-dimensional compact Riemannian manifold(M,g)without boundary and another compact Riemannian manifold(N,h),the authors establish the uniqueness of the heat flow of harmonic maps from M to N in the class C([0,T),W1,n).For the hydrodynamic flow(u,d)of nematic liquid crystals in dimensions n = 2 or 3,it is shown that the uniqueness holds for the class of weak solutions provided either(i)for n = 2,u ∈L∞tL2x∩L2tH1x,▽P∈L3/4tL4/3t,and ▽d∈L∞tL2x∩L2tH2x; or(ⅱ)for n=3,u ∈L∞tL2x∩L2tH1x∩C([0,T),Ln),P∈Ln/2tLn/2x,and▽d∈L2tL2x∩C([0,T),Ln).This answers affirmatively the uniqueness question posed by Lin-Lin-Wang.The proofs are very elementary.

  6. A study of the flow boiling heat transfer in an annular heat exchanger with a mini gap

    Directory of Open Access Journals (Sweden)

    Musiał Tomasz

    2017-01-01

    Full Text Available In this paper the research on flow boiling heat transfer in an annular mini gap was discussed. A one- dimensional mathematical approach was proposed to describe stationary heat transfer in the gap. The mini gap 1 mm wide was created between a metal pipe with enhanced exterior surface and an external tempered glass pipe positioned along the same axis. The experimental test stand consists of several systems: the test loop in which distilled water circulates, the data and image acquisition system and the supply and control system. Known temperature distributions of the metal pipe with enhanced surface and of the working fluid helped to determine, from the Robin boundary condition, the local heat transfer coefficients at the fluid - heated surface contact. In the proposed mathematical model it is assumed that the cylindrical wall is a planar multilayer wall. The numerical results are presented on a chart as function of the heat transfer coefficient along the length of the mini gap.

  7. Heat line analysis for MHD mixed convection flow of nanofluid within a driven cavity containing heat generating block

    Science.gov (United States)

    Parvin, Salma; Siddiqua, Ayesha

    2016-07-01

    Mixed convective flow and heat transfer characteristics of nanofluid inside a double lid driven cavity with a square heat generating block is analyzed numerically based on heat line approach. The water- alumina nanofluid is chosen as the operational fluid through the enclosure. The governing partial differential equations with proper boundary conditions are solved by Finite Element Method using Galerkin's weighted residual scheme. Calculations are performed for different solid volume fraction (χ) of nanoparticles 0 ≤ χ ≤ 0.15. Results are shown in terms of stream lines, isothermal lines, heat lines, average Nusselt number, average velocity and average temperature. An enhancement in heat transfer rate is observed with the increase of nanoparticles volume fraction.

  8. An improved mechanistic critical heat flux model for subcooled flow boiling

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Young Min [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Chang, Soon Heung [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1997-12-31

    Based on the bubble coalescence adjacent to the heated wall as a flow structure for CHF condition, Chang and Lee developed a mechanistic critical heat flux (CHF) model for subcooled flow boiling. In this paper, improvements of Chang-Lee model are implemented with more solid theoretical bases for subcooled and low-quality flow boiling in tubes. Nedderman-Shearer`s equations for the skin friction factor and universal velocity profile models are employed. Slip effect of movable bubbly layer is implemented to improve the predictability of low mass flow. Also, mechanistic subcooled flow boiling model is used to predict the flow quality and void fraction. The performance of the present model is verified using the KAIST CHF database of water in uniformly heated tubes. It is found that the present model can give a satisfactory agreement with experimental data within less than 9% RMS error. 9 refs., 5 figs. (Author)

  9. Distributed measurement of flow rate in conduits using heated fiber optic distributed temperature sensing

    Science.gov (United States)

    Sánchez, Raúl; Zubelzu, Sergio; Rodríguez-Sinobas, Leonor; Juana, Luis

    2016-04-01

    In some cases flow varies along conduits, such as in irrigated land drainage pipes and channels, irrigation laterals and others. Detailed knowledge of flow rate along the conduit makes possible analytical evaluation of water distribution and collection systems performance. Flow rate can change continuously in some systems, like in drainage pipes and channels, or abruptly, like in conduits bifurcations or emitter insertions. A heat pulse along the conduit makes possible to get flow rate from continuity and heat balance equations. Due to the great value of specific heat of water, temperature changes along conduit are smaller than the noise that involves the measurement process. This work presents a methodology that, dealing with the noise of distributed temperature measurements, leads to flow rate determination along pressurized pipes or open channel flows.

  10. Effect of heat transfer on rotating electroosmotic flow through a micro-vessel: haemodynamical applications

    Science.gov (United States)

    Sinha, A.; Mondal, A.; Shit, G. C.; Kundu, P. K.

    2016-08-01

    This paper theoretically analyzes the heat transfer characteristics associated with electroosmotic flow of blood through a micro-vessel having permeable walls. The analysis is based on the Debye-Hückel approximation for charge distributions and the Navier-Stokes equations are assumed to represent the flow field in a rotating system. The velocity slip condition at the vessel walls is taken into account. The essential features of the rotating electroosmotic flow of blood and associated heat transfer characteristics through a micro-vessel are clearly highlighted by the variation in the non-dimensional flow velocity, volumetric flow rate and non-dimensional temperature profiles. Moreover, the effect of Joule heating parameter and Prandtl number on the thermal transport characteristics are discussed thoroughly. The study reveals that the flow of blood is appreciably influenced by the elctroosmotic parameter as well as rotating Reynolds number.

  11. Plural voltage minima in an arc-heated channel flow

    Science.gov (United States)

    Sasoh, A.

    2001-04-01

    In flows through a channel with varying cross-sectional area, the impulse and total enthalpy can be increased by superimposing an electrical discharge. The flow field is determined from the inlet flow condition, channel geometry, and discharge specifications. In this study, steady-state, quasi-one-dimensional flows interacting with an arc discharge are computed numerically. Once the arc column configuration is given, the discharge voltage is computed from the solution of flow field variables. For a constant discharge current, there exist plural column configurations which yield a minimum discharge voltage. This result explains the fluid-dynamic mechanisms of the existence of plural voltage modes in an arcjet operation.

  12. Internal (Annular) and Compressible External (Flat Plate) Turbulent Flow Heat Transfer Correlations.

    Energy Technology Data Exchange (ETDEWEB)

    Dechant, Lawrence [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Smith, Justin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    Here we provide a discussion regarding the applicability of a family of traditional heat transfer correlation based models for several (unit level) heat transfer problems associated with flight heat transfer estimates and internal flow heat transfer associated with an experimental simulation design (Dobranich 2014). Variability between semi-empirical free-flight models suggests relative differences for heat transfer coefficients on the order of 10%, while the internal annular flow behavior is larger with differences on the order of 20%. We emphasize that these expressions are strictly valid only for the geometries they have been derived for e.g. the fully developed annular flow or simple external flow problems. Though, the application of flat plate skin friction estimate to cylindrical bodies is a traditional procedure to estimate skin friction and heat transfer, an over-prediction bias is often observed using these approximations for missile type bodies. As a correction for this over-estimate trend, we discuss a simple scaling reduction factor for flat plate turbulent skin friction and heat transfer solutions (correlations) applied to blunt bodies of revolution at zero angle of attack. The method estimates the ratio between axisymmetric and 2-d stagnation point heat transfer skin friction and Stanton number solution expressions for sub-turbulent Reynolds numbers %3C1x10 4 . This factor is assumed to also directly influence the flat plate results applied to the cylindrical portion of the flow and the flat plate correlations are modified by

  13. Geothermal investigations in Idaho. Part 8. Heat flow study of the Snake River Plain region, Idaho

    Energy Technology Data Exchange (ETDEWEB)

    Brott, C.A.; Blackwell, D.D.; Mitchell, J.C.

    1976-09-01

    The Snake River Plain of Idaho has recent lava flows and a large number of thermal springs and wells. A heat flow study was initiated which, together with available geological and geophysical information, allows a better definition of the geothermal resource and evaluation of the geothermal potential. Local geothermal anomalies were not the objects of this study and have not been studied in detail. The quality of the heat flow values obtained varies as interpretation was necessary to determine geothermal gradients for many of the holes which had disturbances. A major problem in determining the heat flow values is the lack of knowledge of the in situ porosity of the rocks. The heat flow values obtained for the Eastern Snake River Plain are from shallow wells (< 200 m), hence the heat flow there is low (< 0.5 HFU) because of the water movement in the Snake Plain aquifer. The anomalous regional heat flow pattern around the Snake River Plain, together with other geophysical and geological data, suggest the presence of a major crustal heat source. With the exception of the area of the Snake Plain aquifer, high geothermal gradients were found in all areas of southern Idaho (40 to 100/sup 0/C/km). Temperatures hot enough for space heating can be found most anywhere in the Plain at relatively shallow depths (1 to 2 km). Temperatures hot enough for electrical power generation (200/sup 0/C) can be found beneath southern Idaho almost anywhere at depths of 3 to 4 kilometers. The Plain is fault bounded and hot water circulating along the fault zones from depths can be a very important geothermal resource at shallow depths. The margins of the Plain have the highest heat flow values, are the most faulted, and have possibly the highest geothermal resource potential.

  14. The heat budgets of magmatic arcs: Discrepancies between heat flow measurements, volatile fluxes, and interpretations of the geologic record

    Science.gov (United States)

    Van Buer, N. J.

    2015-12-01

    Arc magmatic processes, from differentiation to emplacement, depend crucially on the rate at which heat and magma are supplied to the arc crust. In active arcs, the total heat flow can be estimated relatively directly by measuring and quantifying the amounts of heat lost via conduction, hydrothermal circulation, and eruption. This total heat flow can be used to calculate the implied magmatic flux at depth. Alternatively, magmatic flux in active arcs can be estimated from measured rates of volatile emissions, usually SO2. Unfortunately, heat flow and volatile flux data sufficiently detailed to make these calculations exist for only a handful of active arcs. In the geologic record, rates of arc magmatic flux have most frequently been estimated by measuring the preserved volumes of intrusive and extrusive products and dividing by the geochronologically determined duration of arc activity. This can be converted to heat flow by assuming a certain amount of heat carried per volume of magma. The ranges of magmatic flux estimated via either heat flow or SO2 are similar for modern arcs, but, on average, estimates from the geologic record are lower by about a factor of three (Fig. 1). This discrepancy may indicate that the assumption that preserved igneous rock volumes represent the total advective flux is a poor choice when interpreting the geologic record. Recycling of early solidified magma and loss of cumulates to the mantle may be important, i.e., the time-integrated advective flux might significantly exceed the net preserved intrusive volume. This is also supported by other lines of evidence, including geochemical mass-balance arguments, thermal models of basalt flux needed to allow substantial assimilation and/or crystal fractionation in the lower crust, high-temperature thermochronology in arcs, and thermal models of the conditions necessary to cause large, explosive eruptions from upper crustal magma chambers. Substantial recycling or convection within the arc crust

  15. Utilizing thermal isostasy to estimate sub-lithospheric heat flow and anomalous crustal radioactivity

    Science.gov (United States)

    Hasterok, D.; Gard, M.

    2016-09-01

    While surface heat flow relates to the heat loss through the lithosphere, it can be difficult to quantify and separate the heat produced internally through radiogenic decay from the heat transferred across the base of the lithosphere by mantle convection. In this study, we apply a thermo-isostatic analysis to Australia and estimate the sub-lithospheric and radiogenic heat flow components by employing a simple 1-D conservation of energy model. We estimate an anomalous radiogenic heat production across much of eastern Australia generally accounting for >50 mW m-2, while western Australia appears to have high crustal compositionally corrected elevation, possibly related to chemical buoyancy of the mantle lithosphere. A moderately high sub-lithospheric heat flow (∼40 mW m-2) along the eastern and southeastern coast, including Tasmania, is coincident with locations of Cenozoic volcanism and supports an edge-driven convection hypothesis. However, the pattern of sub-lithospheric heat flow along the margin does not support the existence of hotspot tracks. Thermo-isostatic models such as these improve our ability to identify and quantify crustal from mantle sources of heat loss and add valuable constraints on tectonic and geodynamic models of the continental lithosphere's physical state and evolution.

  16. Effect of Borehole Material on Analytical Solutions of the Heat Transfer Model of Ground Heat Exchangers Considering Groundwater Flow

    Directory of Open Access Journals (Sweden)

    Sangwoo Park

    2016-04-01

    Full Text Available Groundwater flow is one of the most important factors for the design of a ground heat exchanger (GHEX since the thermal environment of the ground around the buried GHEX is significantly affected by heat convection due to the groundwater flow. Several preceding studies have been conducted to develop analytical solutions to the heat transfer model of GHEX with consideration of groundwater flow. One of these solutions is the combined heat transfer model of conduction and convection. However, the developed combined analytical models are inapplicable to all of the configurations of ordinary GHEXs because these solutions assume that the inner part of the borehole is thermally inert or consists of the same material as that of the surrounding ground. In this paper, the applicability of the combined solid cylindrical heat source model, which is the most suitable to energy piles until now, was evaluated by performing a series of numerical analyses. In the numerical analysis, the inner part of the borehole was modeled as two different materials (i.e., permeable ground formation and impermeable fill such as concrete to evaluate applicability of the analytical solution along with different diameter-length (D/L ratios of borehole. In a small value of the D/L ratio, the analytical solution to the combined heat transfer model is in good agreement with the result of numerical analysis. On the other hand, when increasing the D/L ratio, the analytical solution significantly overestimates the effect of groundwater flow on the heat transfer of GHEXs because the analytical solution disregards the existence of the impermeable region in the borehole. Consequently, such tendency is more critical in the GHEX with a large D/L ratio such as large-diameter energy piles.

  17. Effect of Internal Flow Patterns on Heat transfer Performance of a Closed-end Oscillating Heat Pipe at Vertical Position

    Directory of Open Access Journals (Sweden)

    S. Rittidech

    2007-01-01

    Full Text Available This article describes the effects of varying bond numbers (Bo and aspect ratios (Le/d on flow pattern of a close-end oscillating heat-pipe (CEOHP. The CEOHPs used employed a glass tube with inside diameter of 3 mm. The length of evaporator of 100 and 150 mm (the lengths of evaporator adiabatic and condenser section were equal were employed with 10 turns. Observation of the flow pattern was conducted at 90° from the horizontal plane, with bond numbers of 1.8 and 2.6 with aspect ratios of 33.3 and 50. R141b and ethanol were used as the working fluids with filling ratio of 50% of internal volume of tube. The evaporator section was heated by heater and the condenser section was cooled by distilled water. The working temperature was controlled at 50°C. The temperature at adiabatic section and the inlet-outlet of distilled water at condenser section were recorded. The photographs of flow patterns at specific times were recorded at evaporator section by a digital camera and video camera were used to observe the flow patterns at evaporator section condenser together with adiabatic section and total part of CEOHP. It was found that the maximum heat flux occurred with Le/d 33 and Bo 2.6 an inside phenomena occurred is a dispersed bubble flow and slug flow.

  18. Newtonian heating effect on unsteady hydromagnetic Casson fluid flow past a flat plate with heat and mass transfer

    Directory of Open Access Journals (Sweden)

    M. Das

    2015-12-01

    Full Text Available The influence of Newtonian heating on heat and mass transfer in unsteady hydromagnetic flow of a Casson fluid past a vertical plate in the presence of thermal radiation and chemical reaction is studied. The Casson fluid model is used to distinguish the non-Newtonian fluid behavior. The fluid flow is induced due to periodic oscillations of the plate along its length and a uniform transverse magnetic field is applied in a direction which is normal to the direction of fluid flow. The partial differential equations governing the flow, heat, and mass transfer are transformed to non-dimensional form using suitable non-dimensional variables which are then solved analytically by using Laplace transform technique. The numerical values of the fluid velocity, fluid temperature, and species concentration are depicted graphically whereas the values of skin-friction, Nusselt number, and Sherwood number are presented in tabular form. It is noticed that the fluid velocity and temperature decrease with increasing values of Casson parameter while concentration decreases with increasing values of chemical reaction parameter and Schmidt number. Such a fluid flow model has several industrial and medical applications such as in glass manufacturing, paper production, purification of crude oil and study of blood flow in the cardiovascular system.

  19. Influence of magmatism on mantle cooling, surface heat flow and Urey ratio

    Science.gov (United States)

    Nakagawa, Takashi; Tackley, Paul J.

    2012-05-01

    Two-dimensional thermo-chemical mantle convection simulations are used to investigate the influence of melting-inducted differentiation on the thermal evolution of Earth's mantle, focussing in particular on matching the present-day surface heat flow and the 'Urey ratio'. The influence of internal heating rate, initial mantle temperature and partitioning of heat-producing elements into basaltic crust are studied. High initial mantle temperatures, which are expected following Earth's accretion, cause major differences in early mantle thermo-chemical structures, but by the present-day surface heat flux and internal structures are indistinguishable from cases with a low initial temperature. Assuming three different values of mantle heat production that vary by more than a factor of two results in small differences in present-day heat flow, as does assuming different partitioning ratios of heat-producing elements into crust. Indeed, all of the cases presented here, regardless of exact parameters, have approximately Earth's present-day heat flow, with substantial fractions coming from the core and from mantle cooling. As a consequence of the model present-day surface heat flow varying only slightly with parameters, the Urey ratio (the ratio of total heat production to the total surface heat flow) is highly dependent on the amount of internal heat production, and due to the large uncertainty in this, the Urey ratio is considered to be a much poorer constraint on thermal evolution than the heat flow. The range of present-day Urey ratio observed in simulations here is about 0.3 to 0.5, which is consistent with observational and geochemical constraints (Jaupart et al., 2007). Magmatic heat transport contributes an upper bound of 9% to Earth's present-day heat loss but a much higher fraction at earlier times—often more than convective heat loss—so neglecting this causes an overestimation of the Urey ratio. Magmatic heat transport also plays an important role in mantle

  20. Heat transfer enhancement in oscillatory flow in channel with periodically upper and lower walls mounted obstacles

    Energy Technology Data Exchange (ETDEWEB)

    Korichi, Abdelkader [Centre Universitaire de Medea, Quartier Ain D' heb, Medea 26000 (Algeria)], E-mail: a_korichi@hotmail.com; Oufer, Lounes [Universite des Sciences et de la Technologie Houari Boumediene, Faculte de Genie Mecanique et de Genie des Procedes, Departement de Genie Chimique et de Cryogenie, Laboratoire des Phenomenes de Transfert, BP 32, El-Alia, Bab-Ezzouar, Alger (Algeria)], E-mail: lounesoufer@yahoo.com

    2007-10-15

    A numerical investigation is conducted in a rectangular channel with heated obstacles mounted alternatively on the upper and lower walls. Time-dependent two dimensional laminar flow with constant thermophysical properties is assumed for air at three values of the Reynolds number (50, 500 and 1000). A detailed analysis is carried out to investigate flow pattern and Nusselt number. Streamwise periodic contraction-expansion of the cross-section induces bifurcation from steady to unsteady flow. In the unsteady state, a self-sustained periodic oscillatory flow occurs. It is also found that a travelling wave generated by the vortex shedding contributes mainly to heat transfer enhancement.

  1. Heat transfer coefficient determination for flow boiling in vertical and horizontal minichannels

    Directory of Open Access Journals (Sweden)

    Piasecka Magdalena

    2014-03-01

    Full Text Available The paper presents the results of boiling heat transfer research during FC-72 laminar flow along a minichannel of 1 mm depth, positioned vertically and horizontally, with an enhanced heating surface. One glass pane allows to determine the temperature of the heating wall by liquid crystal thermography. Calculations are aimed at the evaluation of one- and two-dimensional heat transfer approaches to determine the local heat transfer coefficient. In the one-dimensional approach only the direction of the flow in the channel is considered. In the two-dimensional approach the inverse problem in the heating wall and the direct problem in the glass barrier were solved by the finite element method with Trefftz functions as shape functions (FEMT. The developed flow boiling area was studied. Heat transfer coefficient values obtained for the horizontal minichannel were higher than those obtained for the vertical one. When the heat flux supplied to heating wall grows, the share of gas-phase increases leading to the heat transfer coefficient decreases. The same courses of the experiment were observed for the two applied methods, but the results obtained in the one-dimensional approach are considerably higher than in the two-dimensional one. One-dimensional approach seems to be less sensitive to measurement errors.

  2. Finite element simulation of internal flows with heat transfer using a velocity correction approach

    Indian Academy of Sciences (India)

    B S Varaprasad Patnaik; Y T K Gowda; M S Ravisankar; P A Aswatha Narayana; K N Seetharamu

    2001-06-01

    This paper enumerates finite-element based prediction of internal flow problems, with heat transfer. The present numerical simulations employ a velocity correction algorithm, with a Galerkin weighted residual formulation. Two problems each in laminar and turbulent flow regimes are investigated, by solving full Navier-Stokes equations. Flow over a backward-facing step is studied with extensive validations. The robustness of the algorithm is demonstrated by solving a very complex problem viz. a disk and doughnut baffled heat exchanger, which has several obstructions in its flow path. The effect of wall conductivity in turbulent heat transfer is also studied by performing a conjugate analysis. Temporal evolution of flow in a channel due to circular, square and elliptic obstructions is investigated, to simulate the vortex dynamics. Flow past an in-line tube bank of a heat exchanger shell is numerically studied. Resulting heat and fluid flow patterns are analysed. Important design parameters of interest such as the Nusselt number, Strouhal number, skin friction coefficient, pressure drop etc. are obtained. It is successfully demonstrated that the velocity correction approach with a Galerkin weighted residual formulation is able to effectively simulate a wide range of fluid flow features.

  3. Mechanism and numerical analysis of heat transfer enhancement in the core flow along a tube

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The present study introduces the principles of enhanced heat transfer in the core flow to form an equivalent thermal boundary layer in the fully developed laminar tube flow, which consequently enlarges the temperature gradient of the fluid near the tube wall, and thereby enhances the heat transfer between the fluid and the tube wall. At the same time, the increase of flow resistance in the tube is not so obvious. Mechanism analysis and numerical calculation based on air and water have been carried out to verify the principle and method presented in this paper, which may bring positive effects to the design of heat exchanger with high heat transfer efficiency and low flow resistance.

  4. Convective Heat Transfer Enhancement of a Rectangular Flat Plate by an Impinging Jet in Cross Flow

    Institute of Scientific and Technical Information of China (English)

    李国能; 郑友取; 胡桂林; 张治国

    2014-01-01

    Experiments were carried out to study the heat transfer performance of an impinging jet in a cross flow. Several parameters including the jet-to-cross-flow mass ratio (X=2%-8%), the Reynolds number (Red=1434-5735) and the jet diameter (d=2-4 mm) were explored. The heat transfer enhancement factor was found to increase with the jet-to-cross-flow mass ratio and the Reynolds number, but decrease with the jet diameter when other parameters maintain fixed. The presence of a cross flow was observed to degrade the heat transfer performance in respect to the effect of impinging jet to the target surface only. In addition, an impinging jet was confirmed to be capable of en-hancing the heat transfer process in considerable amplitude even though the jet was not designed to impinge on the target surface.

  5. FEFLOW finite element modeling of flow, mass and heat transport in porous and fractured media

    CERN Document Server

    Diersch, Hans-Jörg G

    2013-01-01

    Placing advanced theoretical and numerical methods in the hands of modeling practitioners and scientists, this book explores the FEFLOW system for solving flow, mass and heat transport processes in porous and fractured media. Offers applications and exercises.

  6. Mixed convection flow and heat transfer in a vertical wavy channel ...

    African Journals Online (AJOL)

    user

    Keywords: convective flow; wavy channel; porous medium; traveling thermal waves. ... the problems of forced convection in composite fluids and porous layers. ... Processes involving heat and mass transfer are often encountered in the ...

  7. Numerical analysis of fluid flow and heat transfer in a helical ...

    African Journals Online (AJOL)

    DR OKE

    numerical study to investigate three-dimensional turbulent developing convective ... numerical study on double-pipe helical heat exchanger modeled for laminar fluid flow and ... Boundary layer mesh was generated for both nozzle and helix.

  8. Heat flow distribution and thermal structure of the Nankai subduction zone off the Kii Peninsula

    Science.gov (United States)

    Hamamoto, Hideki; Yamano, Makoto; Goto, Shusaku; Kinoshita, Masataka; Fujino, Keiko; Wang, Kelin

    2011-10-01

    Detailed heat flow surveys were carried out in the central part of the Nankai Trough southeast of the Kii Peninsula (off Kumano) for investigation of the thermal structure of the subducting plate interface. At stations in the Kumano Trough (forearc basin) and its vicinity, long-term monitoring of temperature profiles in surface sediments was conducted because bottom water temperature variations (BTV) significantly disturb subbottom sediment temperatures. Heat flow values were successfully determined at seven stations by removing the influence of BTV from temperature records for 300 to 400 days. The surface heat flow data were combined with estimates from depths of methane hydrate bottom simulating reflectors to construct a heat flow profile across the subduction zone. Heat flow decreases from 90-110 mW/m2 on the floor of the Nankai Trough to 50-60 mW/m2 at around 30 km from the deformation front, while it is rather uniform, 40-60 mW/m2, in the Kumano Trough. The values measured on the Nankai Trough floor are concordant with the value estimated from the age of the subducting Philippine Sea plate, about 20 m.y., taking into account the effect of sedimentation. The obtained heat flow profile was used to constrain thermal models of the subduction zone. The subsurface thermal structure was calculated using a two-dimensional, steady state model, in which the frictional heating along the plate interface and the radioactive heat production are treated as unknown parameters. Comparison of the calculated surface heat flow in the Kumano Trough with the observed data indicates that the effective coefficient of friction is small, about 0.1 or less, and thus the shear stress on the plate interface is very low in this subduction zone.

  9. Heat dissipation and information flow for delayed bistable Langevin systems near coherence resonance

    Science.gov (United States)

    Xiao, Tiejun

    2016-11-01

    In this paper, stochastic thermodynamics of delayed bistable Langevin systems near coherence resonance is discussed. We calculate the heat dissipation rate and the information flow of a delayed bistable Langevin system under various noise intensities. Both the heat dissipation rate and the information flow are found to be bell-shaped functions of the noise intensity, which implies that coherence resonance manifests itself in the thermodynamic properties.

  10. Double tube heat exchanger with novel enhancement: Part I - flow development length and adiabatic friction factor

    Energy Technology Data Exchange (ETDEWEB)

    Tiruselvam, R.; Raghavan, Vijay R. [Universiti Teknologi PETRONAS, Faculty of Mechanical Engineering, Tronoh (Malaysia)

    2012-04-15

    The study is conducted to evaluate the flow characteristics in a double tube heat exchanger using two new and versatile enhancement configurations. The novelty is that they are usable in single phase forced convection, evaporation and condensation. Correlations are proposed for flow development length and friction factor for use in predicting fluid pumping power in thermal equipment as well as in subsequent heat transfer characterization of the surface. (orig.)

  11. Joule-Thomson effect and internal convection heat transfer in turbulent He II flow

    Science.gov (United States)

    Walstrom, P. L.

    1988-01-01

    The temperature rise in highly turbulent He II flowing in tubing was measured in the temperature range 1.6-2.1 K. The effect of internal convection heat transport on the predicted temperature profiles is calculated from the two-fluid model with mutual friction. The model predictions are in good agreement with the measurements, provided that the pressure gradient term is retained in the expression for internal convection heat flow.

  12. Joule-Thomson effect and internal convection heat transfer in turbulent He II flow

    Science.gov (United States)

    Walstrom, P. L.

    1988-03-01

    The temperature rise in highly turbulent He II flowing in tubing was measured in the temperature range 1.6-2.1 K. The effect of internal convection heat transport on the predicted temperature profiles is calculated from the two-fluid model with mutual friction. The model predictions are in good agreement with the measurements, provided that the pressure gradient term is retained in the expression for internal convection heat flow.

  13. Heat transfer and pressure drop for air flow through enhanced passages. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Obot, N.T.; Esen, E.B.

    1992-06-01

    An extensive experimental investigation was carried out to determine the pressure drop and heat transfer characteristics for laminar, transitional and turbulent flow of air through a smooth passage and twenty-three enhanced passages. The internal surfaces of all enhanced passages had spirally shaped geometries; these included fluted, finned/ribbed and indented surfaces. The Reynolds number (Re) was varied between 400 and 50000. The effect of heat transfer (wall cooling or fluid heating) on pressure drop is most significant within the transition region; the recorded pressure drop with heat transfer is much higher than that without heat transfer. The magnitude of this effect depends markedly on the average surface temperature and, to a lesser extent, on the geometric characteristics of the enhanced surfaces. When the pressure drop data are reduced as values of the Fanning friction factor(f), the results are about the same with and without heat transfer for turbulent flow, with moderate differences in the laminar and transition regions.

  14. Heat transfer and pressure drop for air flow through enhanced passages

    Energy Technology Data Exchange (ETDEWEB)

    Obot, N.T.; Esen, E.B.

    1992-06-01

    An extensive experimental investigation was carried out to determine the pressure drop and heat transfer characteristics for laminar, transitional and turbulent flow of air through a smooth passage and twenty-three enhanced passages. The internal surfaces of all enhanced passages had spirally shaped geometries; these included fluted, finned/ribbed and indented surfaces. The Reynolds number (Re) was varied between 400 and 50000. The effect of heat transfer (wall cooling or fluid heating) on pressure drop is most significant within the transition region; the recorded pressure drop with heat transfer is much higher than that without heat transfer. The magnitude of this effect depends markedly on the average surface temperature and, to a lesser extent, on the geometric characteristics of the enhanced surfaces. When the pressure drop data are reduced as values of the Fanning friction factor(f), the results are about the same with and without heat transfer for turbulent flow, with moderate differences in the laminar and transition regions.

  15. Numerical Simulation of Flow Through Equilateral Triangular Duct Under Constant Wall Heat Flux Boundary Condition

    Science.gov (United States)

    Kumar, Rajneesh; Kumar, Anoop; Goel, Varun

    2017-06-01

    The force convective heat transfer in an equilateral triangular duct of different wall heat flux configurations was analysed for the laminar hydro-dynamically developed and thermally developing flow by the use of finite volume method. Unstructured meshing was generated by multi-block technique and set of governing equations were discretized using second-order accurate up-wind scheme and numerically solved by SIMPLE Algorithm. For ensuring accuracy, grid independence study was also done. Numerical methodology was verified by comparing results with previous work and predicted results showed good agreement with them (within error of ±5 %). The different combinations of constant heat flux boundary condition were analysed and their effect on heat transfer and fluid flow for different Reynolds number was also studied. The results of different combinations were compared with the case of force convective heat transfer in the equilateral triangular duct with constant heat flux on all three walls.

  16. Unsteady boundary layer flow and heat transfer of a Casson fluid past an oscillating vertical plate with Newtonian heating.

    Science.gov (United States)

    Hussanan, Abid; Zuki Salleh, Mohd; Tahar, Razman Mat; Khan, Ilyas

    2014-01-01

    In this paper, the heat transfer effect on the unsteady boundary layer flow of a Casson fluid past an infinite oscillating vertical plate with Newtonian heating is investigated. The governing equations are transformed to a systems of linear partial differential equations using appropriate non-dimensional variables. The resulting equations are solved analytically by using the Laplace transform method and the expressions for velocity and temperature are obtained. They satisfy all imposed initial and boundary conditions and reduce to some well-known solutions for Newtonian fluids. Numerical results for velocity, temperature, skin friction and Nusselt number are shown in various graphs and discussed for embedded flow parameters. It is found that velocity decreases as Casson parameters increases and thermal boundary layer thickness increases with increasing Newtonian heating parameter.

  17. MHD flow and heat transfer of a micropolar fluid over a stretching surface with heat generation (absorption and slip velocity

    Directory of Open Access Journals (Sweden)

    Mostafa A.A. Mahmoud

    2012-04-01

    Full Text Available In this work, the effects of slip velocity on the flow and heat transfer for an electrically conducting micropolar fluid over a permeable stretching surface with variable heat flux in the presence of heat generation (absorption and a transverse magnetic field are investigated. The governing partial differential equations describing the problem are converted to a system of non-linear ordinary differential equations by using the similarity transformation, which is solved numerically using the Chebyshev spectral method. The effects of the slip parameter on the flow, micro-rotation and temperature profiles as well as on the local skin-friction coefficient, the wall couple stress and the local Nusselt number are presented graphically. The numerical results of the local skin-friction coefficient, the wall couple stress and the local Nusselt number are given in a tabular form and discussed.

  18. Flow boiling critical heat flux enhancement by using magnetic nanofluids and external magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Lee, T.; Jeong, Y.H. [Korea Advanced Inst. of Science and Tech., Daejeon (Korea, Republic of)

    2011-07-01

    By using the nanofluid as a working fluid, we can expect the enhancement in the flow boiling critical heat flux mainly due to the deposition of nanoparticles on the heat transfer surface. In this study, we suggest the magnetic nanofluid, or magnetite-water nanofluid, as a working fluid which is regarded as a controllable nanofluid, that is, nanoparticles or magnetite nanoparticles in a nanofluid can be controlled by an external magnetic field. Therefore, we can expect the advantages of magnetic nanofluid such as, i) control of nanofluid concentration to maintain nanoparticle suspension and to localize nanofluid concentration, and ii) removal of nanoparticle from nanofluid when we want. In this study, we focused on the investigation of flow boiling critical heat flux characteristics for the magnetic nanofluid. Series of experiments were performed under the low pressure and low flow conditions, and based on the experimental results; we can conclude that the use of magnetic nanofluid improves the flow boiling critical heat flux characteristics. This is mainly due to the deposition of magnetite nanoparticles on the heat transfer surface, which results in the improvement of wettability and re-wetting characteristics of heat transfer surface. Preliminary results of the magnetic field effects on the flow boiling critical heat flux would be presented also. (author)

  19. Experimental and Exergy Analysis of A Double Pipe Heat Exchanger for Parallel Flow Arrangement

    Directory of Open Access Journals (Sweden)

    Parth P. Parekh

    2014-07-01

    Full Text Available This paper presents For Experimental and Exergy Analysis of a Double Pipe Heat Exchanger for Parallel- flow Arrangement. The Double pipe heat exchanger is one of the Different types of heat exchangers. double-pipe exchanger because one fluid flows inside a pipe and the other fluid flows between that pipe and another pipe that surrounds the first.In a parallel flow, both the hot and cold fluids enter the Heatexchanger at same end andmove in same direction. The present work is taken up to carry experimental work and the exergy analysis based on second law analysis of a Double-Pipe Heat Exchanger. In experimental set up hot water and cold water will be used working fluids. The inlet Hot water will be varied from 40 0C and 50 0C and cold water temperature will be varied from between 15 and 20 0C. It has been planned to find effects of the inlet condition of both working fluid flowing through the heat exchanger on the heat transfer characteristics, entropy generation, and Exergy loss. The Mathematical modelling of heat exchanger will based on the conservation equation of mass, energy and based on second law of thermodynamics to find entropy generation and exergy losses.

  20. Heat Transfer Enhancement Due to Marangoni Flow Around Moving Bubbles During Nucleate Boiling

    Institute of Scientific and Technical Information of China (English)

    David M. Christopher; WANG Hao; PENG Xiaofeng

    2006-01-01

    Nucleate boiling is a very efficient method for generating high heat transfer rates from solid surfaces; however, the fundamental physical mechanisms governing nucleate boiling heat transfer are not well understood. The heat transfer mechanisms around stationary and moving bubbles on very thin microwires were analyzed numerically to evaluate the effect of the bubble motion on the heat transfer from the wire surface. The numerical analysis accurately models the experimentally observed bubble movement and fluid velocities. The analytical model includes the effects of the Marangoni flow around the bubble and the evaporation and condensation within the bubble. The analysis shows that the heat transfer was significantly enhanced by the Marangoni flow around the outside of the bubble which transfers at least twice as much energy from the wire as the heat transfer directly from the wire to the bubble. The enhanced heat transfer due to the Marangoni flow was evident for both stationary and moving bubbles. The moving bubbles also created a wake that further enhanced the heat transfer from the wire. Since the Marangoni number for water is greater than for ethanol for the same conditions, the Marangoni flow and, hence, the bubble velocities are predicted to be greater in water than in ethanol.

  1. Convective Heat Transfer in Internal Gas Flows with Temperature-Dependent Properties.

    Science.gov (United States)

    1982-06-30

    effects of variable properties have been provided by Petukhov [1970],specifically for turbulent flow in circular tubes.and by Leontiev o for the...243-249. Leontiev , A. I., 1966. Heat and mass transfer in turbulent boundary layers, Adv. Heat Transfer, 3, pp. 33-100. Leung, E. Y., V. M. Kays and W

  2. Atomistic-Continuum Hybrid Simulation of Heat Transfer between Argon Flow and Copper Plates

    CERN Document Server

    Mao, Yijin; Chen, C L

    2016-01-01

    A simulation work aiming to study heat transfer coefficient between argon fluid flow and copper plate is carried out based on atomistic-continuum hybrid method. Navier-Stokes equations for continuum domain are solved through the Pressure Implicit with Splitting of Operators (PISO) algorithm, and the atom evolution in molecular domain is solved through the Verlet algorithm. The solver is validated by solving Couette flow and heat conduction problems. With both momentum and energy coupling method applied, simulations on convection of argon flows between two parallel plates are performed. The top plate is kept as a constant velocity and has higher temperature, while the lower one, which is modeled with FCC copper lattices, is also fixed but has lower temperature. It is found that, heat transfer between argon fluid flow and copper plate in this situation is much higher than that at macroscopic when the flow is fully developed.

  3. Heat flow pattern at the Chicxulub impact crater, northern Yucatan, Mexico

    Science.gov (United States)

    Espinosa-Cardeña, J. M.; Campos-Enríquez, J. O.; Unsworth, M.

    2016-02-01

    Along an east-west profile crossing the Chicxulub impact structure in northern Yucatán, México, Curie depths were obtained from statistical-spectral analysis of a grid of aeromagnetic data (256 km wide and 600 km long). These depths were corrected for flight height and depth to the sea floor to determine the geothermal gradient, assuming a temperature of 580 °C for the Curie temperature. Heat flow was then calculated from the geothermal gradients using a value of 2.67 W/m-K for the mean crustal thermal conductivity. The results show a conspicuous heat flow high above on the impact basin. In this location, the heat flow is 80 mW/m2 approximately. Available offshore estimates of the depth to the crustal magnetic source bases, on the northern Yucatán platform, and onshore heat flow determination on 8 shallow bore holes, and in a 1511 m deep one, support the existence of this major high heat flow anomaly associated with the impact crater. This high heat flow might be related to the impact through: (1) an uplift of the crystalline basement rocks in the center of the crater; and (2) impact induced radioactive element concentration into the crust below the impact structure. Higher thermal conductivities at the lower crust might also play a key role. Available seismological and thermal property data are compatible with these mechanisms.

  4. Local heat transfer in an in-line tube bundle with asymmetrical flow

    DEFF Research Database (Denmark)

    Meyer, Knud Erik

    1999-01-01

    Measurements of the local heat transfer in themiddle of a small in-line tube bundle with longitudinal to transverse pitches of $1.5\\times 1.8$ are performed at a Reynolds number of $30\\,000$. Asymmetrical distributions of the local heat transfer are found. The distributions are in good agreement...... with earlier flow measurements. The mean heat transfer rate is only little affected bythe asymmetrical conditions....

  5. Flow and Heat Transfer Characteristics behind Circular Cylinders with Different Size

    OpenAIRE

    布施, 肇; 鳥居, 修一; 有薗, 美和; フセ, ハジメ; トリイ, シュウイチ; アリゾノ, ミワ; FUSE, Hajime; Torii, Shuichi; ARIZONO, Miwa

    1992-01-01

    An experimental study is conducted on heat transfer from slightly heated circular cylinders with various diameters in cross flow under the same condition of the free-stream turbulence. Emphasis is placed on the influence of the diameter of the cylinder, D, on the heat transfer coefficient at the rear stagnation point. By using a hot-wire anemometer, spectrum analysis of the anemometer signal with a Fourier analyzer is etmployed to investigate the separated shear layer formed behind the circul...

  6. A Study of Heat Transfer and Flow Characteristics of Rising Taylor Bubbles

    Science.gov (United States)

    Scammell, Alexander David

    2016-01-01

    Practical application of flow boiling to ground- and space-based thermal management systems hinges on the ability to predict the systems heat removal capabilities under expected operating conditions. Research in this field has shown that the heat transfer coefficient within two-phase heat exchangers can be largely dependent on the experienced flow regime. This finding has inspired an effort to develop mechanistic heat transfer models for each flow pattern which are likely to outperform traditional empirical correlations. As a contribution to the effort, this work aimed to identify the heat transfer mechanisms for the slug flow regime through analysis of individual Taylor bubbles.An experimental apparatus was developed to inject single vapor Taylor bubbles into co-currently flowing liquid HFE 7100. The heat transfer was measured as the bubble rose through a 6 mm inner diameter heated tube using an infrared thermography technique. High-speed flow visualization was obtained and the bubble film thickness measured in an adiabatic section. Experiments were conducted at various liquid mass fluxes (43-200 kgm2s) and gravity levels (0.01g-1.8g) to characterize the effect of bubble drift velocityon the heat transfer mechanisms. Variable gravity testing was conducted during a NASA parabolic flight campaign.Results from the experiments showed that the drift velocity strongly affects the hydrodynamics and heat transfer of single elongated bubbles. At low gravity levels, bubbles exhibited shapes characteristic of capillary flows and the heat transfer enhancement due to the bubble was dominated by conduction through the thin film. At moderate to high gravity, traditional Taylor bubbles provided small values of enhancement within the film, but large peaks in the wake heat transfer occurred due to turbulent vortices induced by the film plunging into the trailing liquid slug. Characteristics of the wake heat transfer profiles were analyzed and related to the predicted velocity field

  7. Effects of forced wall vibration on the onset of flow instability and critical heat flux in uniformly-heated microchannels

    Science.gov (United States)

    Stromberger, Jorg Hermann

    Numerous experimental and theoretical investigations on two-phase flow instability and burnout in heated microchannels have been reported in the literature. However none of these investigations deals with the possible effects of wall vibrations on such flow boiling processes within microchannels. Fluid-structure interaction in ultra high power density systems cooled by high velocity single phase forced convection in microchannels may result in vibration amplitudes that are a significant fraction of the diameter of the channel. Such vibrations may significantly impact vapor bubble dynamics at the wall and, hence, the limiting heat fluxes corresponding to the onset of flow instability and/or burnout. The primary purpose of this research was to experimentally quantify the effect of forced wall vibration on the onset of flow instability (OFI) and the critical heat flux (CHF) in uniformly-heated annular microchannels. The secondary interest of this investigation was to compare the experimental data collected in the single-phase regime to commonly used single-phase forced convection correlations. Experimental data acquired in the flow boiling regime were to be utilized to confirm the validity of common flow boiling correlations for microchannel flow. The influence of forced wall vibration on subcooled single-phase forced convection and flow boiling was examined. The Georgia Tech Microchannel Test Facility (GTMTF) was modified to allow such experiments to be conducted at controlled values of transverse wall vibration amplitudes and accelerations for a range of frequencies. The channel demand curves were obtained for various inner and outer surface heat fluxes. Experiments were conducted for broad ranges of transverse wall vibration amplitudes over a range of frequencies. The experiments conducted in this investigation provide designers of high power density systems cooled by forced convection in microchannels with the appropriate data and correlations to confidently

  8. A study of sensing heat flow through thermal walls by using thermoelectric module

    Directory of Open Access Journals (Sweden)

    Sippawit Noppawit

    2015-01-01

    Full Text Available Demands on heat flow detection at a plane wall via a thermoelectric module have drawn researchers’ attention to quantitative understanding in order to properly implement the thermoelectric module in thermal engineering practices. Basic mathematical models of both heat transfer through a plane wall and thermoelectric effects are numerically solved to represent genuine behaviors of heat flow detection by mounting a thermoelectric module at a plane wall. The heat transfer through the plane wall is expected to be detected. It is intriguing from simulation results that the heat rejected at the plane wall is identical to the heat absorbed by the thermoelectric module when the area of the plane wall is the same as that of the thermoelectric module. Furthermore, both the area sizes of the plane walls and the convective heat transfer coefficients at the wall influence amount of the heat absorbed by the thermoelectric module. Those observational data are modeled for development of sensing heat flow through a plane wall by a thermoelectric module in practical uses.

  9. Heat Transfer Computations of Internal Duct Flows With Combined Hydraulic and Thermal Developing Length

    Science.gov (United States)

    Wang, C. R.; Towne, C. E.; Hippensteele, S. A.; Poinsatte, P. E.

    1997-01-01

    This study investigated the Navier-Stokes computations of the surface heat transfer coefficients of a transition duct flow. A transition duct from an axisymmetric cross section to a non-axisymmetric cross section, is usually used to connect the turbine exit to the nozzle. As the gas turbine inlet temperature increases, the transition duct is subjected to the high temperature at the gas turbine exit. The transition duct flow has combined development of hydraulic and thermal entry length. The design of the transition duct required accurate surface heat transfer coefficients. The Navier-Stokes computational method could be used to predict the surface heat transfer coefficients of a transition duct flow. The Proteus three-dimensional Navier-Stokes numerical computational code was used in this study. The code was first studied for the computations of the turbulent developing flow properties within a circular duct and a square duct. The code was then used to compute the turbulent flow properties of a transition duct flow. The computational results of the surface pressure, the skin friction factor, and the surface heat transfer coefficient were described and compared with their values obtained from theoretical analyses or experiments. The comparison showed that the Navier-Stokes computation could predict approximately the surface heat transfer coefficients of a transition duct flow.

  10. Heat transfer and flow in high-temperature alkali-metal heat pipes

    Science.gov (United States)

    Nosach, N. A.; Gontarev, Iu. K.; Prisniakov, V. F.; Iakovenko, A. G.; Kostornov, A. G.

    1982-06-01

    An experimental study of the dynamics of heat pipes with steel wool and metal fiber wicks, in particular of startup and transition from one operating mode to another, is presented. The dynamics effect of the initial heat flux in the evaporator when NaK is the working fluid is determined. The effect of interaction between the liquid and vapor phases on the heat and mass transfer from the vapor condensing on the pipe wall is analyzed.

  11. Assessment of heat sources on the control of fast flow of Vestfonna ice cap, Svalbard

    Science.gov (United States)

    Schäfer, M.; Gillet-Chaulet, F.; Gladstone, R.; Pettersson, R.; Pohjola, V. A.; Strozzi, T.; Zwinger, T.

    2014-10-01

    Understanding the response of fast flowing ice streams or outlet glaciers to changing climate is crucial in order to make reliable projections of sea level change over the coming decades. Motion of fast outlet glaciers occurs largely through basal motion governed by physical processes at the glacier bed, which are not yet fully understood. Various subglacial mechanisms have been suggested for fast flow but common to most of the suggested processes is the requirement of presence of liquid water, and thus temperate conditions. We use a combination of modelling, field, and remote observations in order to study links between different heat sources, the thermal regime and basal sliding in fast flowing areas on Vestfonna ice cap. A special emphasis lies on Franklinbreen, a fast flowing outlet glacier which has been observed to accelerate recently. We use the ice flow model Elmer/Ice including a Weertman type sliding law and a Robin inverse method to infer basal friction parameters from observed surface velocities. Firn heating, i.e. latent heat release through percolation of melt water, is included in our model; its parameterisation is calibrated with the temperature record of a deep borehole. We found that strain heating is negligible, whereas friction heating is identified as one possible trigger for the onset of fast flow. Firn heating is a significant heat source in the central thick and slow flowing area of the ice cap and the essential driver behind the ongoing fast flow in all outlets. Our findings suggest a possible scenario of the onset and maintenance of fast flow on the Vestfonna ice cap based on thermal processes and emphasise the role of latent heat released through refreezing of percolating melt water for fast flow. However, these processes cannot yet be captured in a temporally evolving sliding law. In order to simulate correctly fast flowing outlet glaciers, ice flow models not only need to account fully for all heat sources, but also need to incorporate

  12. Abnormal high surface heat flow caused by the Emeishan mantle plume

    Science.gov (United States)

    Jiang, Qiang; Qiu, Nansheng; Zhu, Chuanqing

    2016-04-01

    It is commonly believed that increase of heat flow caused by a mantle plume is small and transient. Seafloor heat flow data near the Hawaiian hotspot and the Iceland are comparable to that for oceanic lithosphere elsewhere. Numerical modeling of the thermal effect of the Parana large igneous province shows that the added heat flow at the surface caused by the magmatic underplating is less than 5mW/m2. However, the thermal effect of Emeishan mantle plume (EMP) may cause the surface hear-flow abnormally high. The Middle-Late Emeishan mantle plume is located in the western Yangtze Craton. The Sichuan basin, to the northeast of the EMP, is a superimposed basin composed of Paleozoic marine carbonate rocks and Mesozoic-Cenozoic terrestrial clastic rocks. The vitrinite reflectance (Ro) data as a paleogeothermal indicator records an apparent change of thermal regime of the Sichuan basin. The Ro profiles from boreholes and outcrops which are close to the center of the basalt province exhibit a 'dog-leg' style at the unconformity between the Middle and Upper Permian, and they show significantly higher gradients in the lower subsection (pre-Middle Permian) than the Upper subsection (Upper Permian to Mesozoic). Thermal history inversion based on these Ro data shows that the lower subsection experienced a heat flow peak much higher than that of the upper subsection. The abnormal heat flow in the Sichuan basin is consistent with the EMP in temporal and spatial distribution. The high-temperature magmas from deep mantle brought heat to the base of the lithosphere, and then large amount of heat was conducted upwards, resulting in the abnormal high surface heat flow.

  13. Feedback Heating in Cooling Flow Clusters With Slow Jets

    CERN Document Server

    Soker, N; Soker, Noam; Pizzolato, Fabio

    2004-01-01

    We propose a scenario in which a large fraction, or even most, of the gas cooling to low temperatures (T<10^4 K) in cooling flow clusters, directly gains energy from the central black hole. Most of the cool gas is accelerated to non-relativistic high velocities, v = 10^3-10^4 km/s, after flowing through, or close to, an accretion disk around the central black hole. A poorly collimated wind (or double not-well collimated opposite jets) is formed. According to the proposed scenario, this gas inflates some of the X-ray deficient bubbles, such that the average gas temperature inside these bubbles (cavities) in cooling flow clusters is kT_b~100 keV. This scenario is incorporated into the moderate cooling flow model; although not a necessary ingredient in that model, it brings it to better agreement with observations. In the moderate cooling flow model a cooling flow does exist, but the mass cooling rate is <10% of that in old versions of cooling flow models.

  14. Analysis Heat Flow Between Seat and Valve of ICE

    Directory of Open Access Journals (Sweden)

    M. H. Shojaefard

    2007-01-01

    Full Text Available An interesting application of system identification method is to investigate the heat transfer from the exhaust valve, especially the valve burning at high temperatures. This study consists of experimental and analytical works. For the experiment, two co-axial rods were used to transfer heat constantly at their contact surfaces. Using the measured temperatures at different locations of the rods and the analytical method, the temperatures distribution of the rods were calculated; consequently the heat transfer coefficient at contact surface was calculated. By applying the system identification method and having the temperatures at both sides of the contact surface, the temperature transfer function was calculated. The transfer function is changed as the operating conditions are varied. Using the calculated transfer function and the system identification method, a computational model was created. By knowing the temperature of one rod, the temperature of the other rod was estimated with high accuracy.

  15. Experimental study of formation heating during radial flow of steam

    Energy Technology Data Exchange (ETDEWEB)

    Malofeev, G.E.; Kennavi, F.A.; Sheinman, A.B.

    1969-06-01

    Hot water or steam was injected into a laboratory model of an oil formation, and the distribution of temperature within the model was determined at different times. The zone of interest in the model was 50 mm thick, thickness of overlying and underlying rock was 140 mm. Model diameter was 600 mm, porosity was 37%, and permeability 4 darcies. Well diameter was 6.5 mm. Dimensionless parameters were determined, so that thermal behavior of the model represented thermal behavior of a reservoir. Both vertical and radial temperature distributions in the model are shown graphically, as well as the relationship between the heat injected into the system and the heat accumulated by the system. It was found that there is formed in the sand a steam zone (zone of constant temperature) whose radius increases with time; and the coefficient of heat utilization does not depend on the quantity of injected steam.

  16. Gentle Heating by Mixing in Cooling Flow Clusters

    Science.gov (United States)

    Hillel, Shlomi; Soker, Noam

    2017-08-01

    We analyze 3D hydrodynamical simulations of the interaction of jets and the bubbles they inflate with the intracluster medium (ICM) and show that the heating of the ICM by mixing hot bubble gas with the ICM operates over tens of millions of years and hence can smooth the sporadic activity of the jets. The inflation process of hot bubbles by propagating jets forms many vortices, and these vortices mix the hot bubble gas with the ICM. The mixing, and hence the heating of the ICM, starts immediately after the jets are launched, but continues for tens of millions of years. We suggest that the smoothing of the active galactic nucleus (AGN) sporadic activity by the long-lived vortices accounts for the recent finding of a gentle energy coupling between AGN heating and the ICM.

  17. Nanoscale thermal AFM of polymers: transient heat flow effects.

    Science.gov (United States)

    Duvigneau, Joost; Schönherr, Holger; Vancso, G Julius

    2010-11-23

    Thermal transport around the nanoscale contact area between the heated atomic force microscopy (AFM) probe tip and the specimen under investigation is a central issue in scanning thermal microscopy (SThM). Polarized light microscopy and AFM imaging of the temperature-induced crystallization of poly(ethylene terephthalate) (PET) films in the region near the tip were used in this study to unveil the lateral heat transport. The radius of the observed lateral surface isotherm at 133 °C ranged from 2.2 ± 0.5 to 18.7 ± 0.5 μm for tip-polymer interface temperatures between 200 and 300 °C with contact times varying from 20 to 120 s, respectively. In addition, the heat transport into polymer films was assessed by measurements of the thermal expansion of poly(dimethyl siloxane) (PDMS) films with variable thickness on silicon supports. Our data showed that heat transport in the specimen normal (z) direction occurred to depths exceeding 1000 μm using representative non-steady-state SThM conditions (i.e., heating from 40 to 180 °C at a rate of 10 °C s(-1)). On the basis of the experimental results, a 1D steady-state model for heat transport was developed, which shows the temperature profile close to the tip-polymer contact. The model also indicates that ≤1% of the total power generated in the heater area, which is embedded in the cantilever end, is transported into the polymer through the tip-polymer contact interface. Our results complement recent efforts in the evaluation and improvement of existing theoretical models for thermal AFM, as well as advance further developments of SThM for nanoscale thermal materials characterization and/or manipulation via scanning thermal lithography (SThL).

  18. Heat transfer in MHD flow due to a linearly stretching sheet with induced magnetic field

    CERN Document Server

    El-Mistikawy, Tarek M A

    2016-01-01

    The full MHD problem of the flow and heat transfer due to a linearly stretching sheet in the presence of a transverse magnetic field is put in a self-similar form. Traditionally ignored physical processes such as induced magnetic field, viscous dissipation, Joule heating, and work shear are included and their importance is established. Cases of prescribed surface temperature, prescribed heat flux, surface feed (injection or suction), velocity slip, and thermal slip are also considered. The problem is shown to admit self similarity. Sample numerical solutions are obtained for chosen combinations of the flow parameters.

  19. Heat flow control in thermo-magnetic convective systems using engineered magnetic fields

    Science.gov (United States)

    Lee, Jaewook; Nomura, Tsuyoshi; Dede, Ercan M.

    2012-09-01

    We present the design of a magnetically controlled convective heat transfer system. The underlying thermo-magnetic instability phenomenon is described, and enhanced convective fluid flow patterns are determined using non-linear programming techniques plus a design sensitivity analysis. Specifically, the magnetic fluid body force is computed by finding the optimal distribution and magnetization direction of a magnetic field source, where the objective is to minimize the maximum temperature of a closed loop heat transfer system. Sizeable fluid recirculation zones are induced by arranging magnetic field generation elements in configurations similar to Halbach arrays. Applications include improved heat flow control for electromechanical systems.

  20. Degradation of the performance of microchannel heat exchangers due to flow maldistribution

    DEFF Research Database (Denmark)

    Nielsen, Kaspar Kirstein; Engelbrecht, Kurt; Christensen, Dennis;

    2012-01-01

    The effect of flow maldistribution on the performance of microchannel parallel plate heat exchangers is investigated using an established single blow numerical model and cyclic steady-state regenerator experiments. It is found that as the variation of the individual channel thickness...... in a particular stack (heat exchanger) increases the actual performance of the heat exchanger decreases significantly, deviating from the expected nominal performance. We show that this is due to both the varying fluid flow velocities in each individual channel and the thermal cross talk between the channels...

  1. Simple heat transfer correlations for turbulent tube flow

    Directory of Open Access Journals (Sweden)

    Taler Dawid

    2017-01-01

    Full Text Available The paper presents three power-type correlations of a simple form, which are valid for Reynolds numbers range from 3·103 ≤ Re ≤ 106, and for three different ranges of Prandtl number: 0.1 ≤ Pr ≤ 1.0, 1.0 < Pr ≤ 3.0, and 3.0 < Pr ≤ 103. Heat transfer correlations developed in the paper were compared with experimental results available in the literature. The comparisons performed in the paper confirm the good accuracy of the proposed correlations. They are also much simpler compared with the relationship of Gnielinski, which is also widely used in the heat transfer calculations.

  2. Simultaneous PIV and thermography measurements of partially blocked flow in a differentially heated rotating annulus

    Energy Technology Data Exchange (ETDEWEB)

    Harlander, Uwe; Alexandrov, Kiril; Wang, Yongtai; Egbers, Christoph [Brandenburg University of Technology Cottbus, Department of Aerodynamics and Fluid Mechanics, Cottbus (Germany); Wenzel, Julia [University of Leipzig, Institute of Meteorology, Leipzig (Germany)

    2012-04-15

    A radial barrier has been mounted in a differentially heated rotating annulus that partially blocks the azimuthal flow component. The experiment can be seen as an analog to geophysical flows with constrictions, e.g., the Antarctic Circumpolar Current. However, the experiment has been carried out without a particular natural flow in mind. The main interest was to observe a baroclinic annulus flow that does not become saturated. Hence, in contrast to the annulus flow without a barrier, the partially blocked flow remains transient and surface heat fluxes associated with baroclinic life cycles can be studied. The annulus can be subdivided into the upstream half of the barrier, where waves amplify, and the downstream half of the barrier, where waves decay. In the upstream half, the azimuthal mean flow is moderate but with a significant positive eddy radial heat flux. In the downstream half, we find a strong jet in the mean azimuthal flow and furthermore an increased radial mean temperature gradient. The latter points to a weakened or even reversed radial eddy heat flux in the lee side of the barrier. Temperature anomalies appear as large bulges in the outer part of the annulus. Moreover, an outward shift of vortex centers can be observed with respect to centers of temperature anomalies. This phase shift between pressure and temperature anomalies differs from that of classical Eady modes of baroclinic instability. (orig.)

  3. Calculation of temperature field in gas flow with internal heat source

    Directory of Open Access Journals (Sweden)

    Gerasimov Alexander V.

    2015-01-01

    Full Text Available Gas flow sequentially moving through three zones (input z1 of a cylindrical channel was considered. Analytical solutions taking into account the influence of heat source limitation in the axial direction and intensity of air flow in this direction on thermal balance were obtained.

  4. The mean condensate heat resistance of dropwise condensation with flowing inert gases

    NARCIS (Netherlands)

    van der Geld, C.W.M.; Brouwers, Jos

    1995-01-01

    The quantification of the condensate heat resistance is studied for dropwise condensation from flowing air-steam mixtures. Flows are essentially laminar and stable with gas Reynolds numbers around 900 and 2000. The condensate shaping up as hemispheres on a plastic plane wall and the presence of iner

  5. The mean condensate heat resistance of dropwise condensation with flowing inert gases

    NARCIS (Netherlands)

    Geld, van der C.W.M.; Brouwers, H.J.H.

    1995-01-01

    The quantification of the condensate heat resistance is studied for dropwise condensation from flowing air-steam mixtures. Flows are essentially laminar and stable with gas Reynolds numbers around 900 and 2000. The condensate shaping up as hemispheres on a plastic plane wall and the presence of iner

  6. Comparision of numerical simulation and flow field visualisation using heating foil

    Science.gov (United States)

    Matejka, Milan; Hyhlik, Tomas

    2012-04-01

    Paper deals with comparison of numerical and experimental solution of the flow field of hump. Synthetic jet actuators were used to influence flow field of the hump. Visualization using heating foil was done and compared with data from numerical simulation. The hump is located in closed measurement area of Eiffel type wind tunnel. Commercial code Fluent was used to perform numerical solution.

  7. The mean condensate heat resistance of dropwise condensation with flowing inert gases

    NARCIS (Netherlands)

    van der Geld, C.W.M.; Brouwers, Jos

    1995-01-01

    The quantification of the condensate heat resistance is studied for dropwise condensation from flowing air-steam mixtures. Flows are essentially laminar and stable with gas Reynolds numbers around 900 and 2000. The condensate shaping up as hemispheres on a plastic plane wall and the presence of

  8. One-dimensional model for heat transfer to a supercritical water flow in a tube

    NARCIS (Netherlands)

    Sallevelt, J.L.H.P.; Withag, J.A.M.; Bramer, E.A.; Brilman, D.W.F.; Brem, G.

    2012-01-01

    Heat transfer in water at supercritical pressures has been investigated numerically using a one-dimensional modeling approach. A 1D plug flow model has been developed in order to make fast predictions of the bulk-fluid temperature in a tubular flow. The chosen geometry is a vertical tube with an inn

  9. Experimental-numerical study of heat flow in deep low-enthalpy geothermal conditions

    NARCIS (Netherlands)

    Saeid, S.; Al-Khoury, R.; Nick, H.M.; Barends, F.

    2014-01-01

    This paper presents an intensive experimental-numerical study of heat flow in a saturated porous domain. A temperature and a flow rate range compared to that existing in a typical deep low-enthalpy hydrothermal system is studied. Two main issues are examined: the effect of fluid density and viscosit

  10. Subcooled flow boiling heat transfer of ethanol aqueous solutions in vertical annulus space

    Directory of Open Access Journals (Sweden)

    Sarafraz M.M.

    2012-01-01

    Full Text Available The subcooled flow boiling heat-transfer characteristics of water and ethanol solutions in a vertical annulus have been investigated up to heat flux 132kW/m2. The variations in the effects of heat flux and fluid velocity, and concentration of ethanol on the observed heat-transfer coefficients over a range of ethanol concentrations implied an enhanced contribution of nucleate boiling heat transfer in flow boiling, where both forced convection and nucleate boiling heat transfer occurred. Increasing the ethanol concentration led to a significant deterioration in the observed heat-transfer coefficient because of a mixture effect, that resulted in a local rise in the saturation temperature of ethanol/water solution at the vapor-liquid interface. The reduction in the heat-transfer coefficient with increasing ethanol concentration is also attributed to changes in the fluid properties (for example, viscosity and heat capacity of tested solutions with different ethanol content. The experimental data were compared with some well-established existing correlations. Results of comparisons indicate existing correlations are unable to obtain the acceptable values. Therefore a modified correlation based on Gnielinski correlation has been proposed that predicts the heat transfer coefficient for ethanol/water solution with uncertainty about 8% that is the least in comparison to other well-known existing correlations.

  11. Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

    Indian Academy of Sciences (India)

    Rambir Bhadouriya; Amit Agrawal; S V Prabhu

    2015-04-01

    The problem of fluid flow and heat transfer was studied for flow inside twisted duct of square cross-section. Three-dimensional numerical solutions were obtained for steady fully developed laminar flow and for uniform wall heat flux boundary conditions using commercially available software. Reynolds number range considered was 100-3000. Twist ratio used are 2.5, 5, 10 and 20. Fluids considered are in Prandtl number range of 0.7-20. Product of friction factor and Reynolds number is found to be a function of Reynolds number and maximum values are observed for a twist ratio of 2.5 and Reynolds number of 3000. Maximum Nusselt number is observed for the same values along with Prandtl number of 20. Correlations for friction factor and Nusselt number are developed involving swirl parameter. Local distribution of friction factor ratio and Nusselt number across a cross-section is presented. Based on constant pumping power criteria, enhancement factor is defined to compare twisted ducts with straight ducts. Selection of twisted square duct is presented in terms of enhancement factor. It is found that twisted duct performs well in the laminar region for range of parameters studied. Heat transfer enhancement for Reynolds number of 3000 and Prandtl number of 0.7 for twist ratio of 2.5, 5, 10, and 20 is 20%, 17.8%, 16.1% and 13.7%, respectively. The results are significant because it will contribute to development of energy efficient compact size heat exchangers.

  12. The numerical investigation of heat transfer and pressure drop of turbulent flow in a triangular microchannel

    Science.gov (United States)

    Rezaei, Omid; Akbari, Omid Ali; Marzban, Ali; Toghraie, Davood; Pourfattah, Farzad; Mashayekhi, Ramin

    2017-09-01

    In this presentation, the flow and heat transfer inside a microchannel with a triangular section, have been numerically simulated. In this three-dimensional simulation, the flow has been considered turbulent. In order to increase the heat transfer of the channel walls, the semi-truncated and semi-attached ribs have been placed inside the channel and the effect of forms and numbers of ribs has been studied. In this research, the base fluid is Water and the effect of volume fraction of Al2O3 nanoparticles on the amount of heat transfer and physics of flow have been investigated. The presented results are including of the distribution of Nusselt number in the channel, friction coefficient and Performance Evaluation Criterion of each different arrangement. The results indicate that, the ribs affect the physics of flow and their influence is absolutely related to Reynolds number of flow. Also, the investigation of the used semi-truncated and semi-attached ribs in Reynolds number indicates that, although heat transfer increases, but more pressure drop arises. Therefore, in this method, in order to improve the heat transfer from the walls of microchannel on the constant heat flux, using the pump is demanded.

  13. Reconnaissance heat flow and Geothermal gradient study in north central Owyhee county, Idaho

    Energy Technology Data Exchange (ETDEWEB)

    Blackwell, D.D.

    1975-09-01

    Temperature data were obtained in 41 wells, thermal conductivity in 12 wells, and published data were synthesized in order to investigate the geothermal character of an area in northern Owyhee County, Idaho. This area includes the Bruneau and Grand View-Castle Creek KGRA's and is characterized by a large number of warm water artesian irrigation wells. In the Oreana-Grand View areas the geothermal gradient to 3000 feet is 4.0 {+-} 1 F/100 ft and the heat flow is about 2.1 {+-} .2 HFU (about normal for the western US). The southern part of the Oreana area along the upper part of Castle Creek and the Little Valley-Bruneau areas have geothermal gradients ranging from 5 to 8 F/100 ft and heat flow values from 50% to 100% above the regional average. Part of the Murphy area has a geothermal gradient of about 4.0 F/100 ft and normal heat flow while the other part has gradients of 6 to 10 F/100 ft and above-regional heat flow. The high values may be directly or indirectly (via geothermal systems) associated with shallow magmatic heat sources, or with regional ground water flow. If local magmatic heat sources are present they may occur along the southern hingeline of the Snake River Plains. Suggests for further work are included.

  14. Thermal models, lithosphere thickness and heat flow in South Portugal. Some comments about the subject

    Science.gov (United States)

    Rosa Duque, Maria

    2016-04-01

    Reinterpretation of old heat flow data or use of new data and new techniques of detection of the temperature under the surface have conducted to new heat flow density values in some regions of the globe. The problem of ice melting in Greenland and Antarctica caught the public's attention to the importance of knowledge on heat flow values and thermal structure of the globe. In the last years, several models were presented trying to obtain lithosphere and Moho thickness of the Iberia Peninsula. The work we intend to present is related with the SW part of the Iberia Peninsula ( south of the Ossa Morena zone, South Portuguese Zone and Algarve). The results obtained show a decrease in the thickness of the crust and the lithosphere in this region. Density anomalies in the crust are also referred. I intend to make the connection between the results of these models and the heat flow thermal conductivity, heat production and geological data available for the region, trying to explain the results of heat flow density data obtained.

  15. Electromagnetohydrodynamic flow of blood and heat transfer in a capillary with thermal radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, A. [Department of Mathematics, Jadavpur University, Kolkata 700032 (India); Shit, G.C., E-mail: gopal_iitkgp@yahoo.co.in [Department of Mathematics, Jadavpur University, Kolkata 700032 (India); Institute of Mathematical Sciences, Chennai 600113 (India)

    2015-03-15

    This paper presents a comprehensive theoretical study on heat transfer characteristics together with fully developed electromagnetohydrodynamic flow of blood through a capillary, having electrokinetic effects by considering the constant heat flux at the wall. The effect of thermal radiation and velocity slip condition have been taken into account. A rigorous mathematical model for describing Joule heating in electro-osmotic flow of blood including the Poisson–Boltzmann equation, the momentum equation and the energy equation is developed. The alterations in the thermal transport phenomenon, induced by the variation of imposed electromagnetic effects, are thoroughly explained through an elegant mathematical formalism. Results presented here pertain to the case where the height of the capillary is much greater than the thickness of electrical double layer comprising the stern and diffuse layers. The essential features of the electromagnetohydrodynamic flow of blood and associated heat transfer characteristics through capillary are clearly highlighted by the variations in the non-dimensional parameters for velocity profile, temperature profile and the Nusselt number. The study reveals that the temperature of blood can be controlled by regulating Joule heating parameter. - Highlights: • Electromagnetohydrodynamic flow of blood in capillary is studied. • Potential electric field is applied for driving elecroosmotic flow of blood. • Effect of thermal radiation, Joule heating and velocity slip is investigated. • Thermal radiation bears the significant change in the temperature field.

  16. Heat flow and thermal processes in the Jornada delMuerto, New Mexico

    Science.gov (United States)

    Reiter, M.

    1985-01-01

    Most heat flow data in rifts are uncertain largely because of hydrologic disturbances in regions of extensive fracturing. Estimates of heat flow in deep petroleum tests within a large basin of the Rio Grande rift, which has suffered little syn-rift fracturing, may begin to provide clearer insight into the relationships between high heat flow and crustal thinning processes. The Jornada del Muerto is a large basin located in the Rio Grande rift of south central New Mexico. The region of interest within the Jornada del Muerto is centered about 30 km east of the town of Truth or Consequences, and is approximately 60 km north-south by 30 km east-west. High heat flows are estimated for the region. Values increase from about 90 mWm(-2) in the northern part of the study area to about 125 mWm(-2) in the southern part. These high heat flows are rather enigmatic because in the immediate vicinities of the sites there is little evidence of Cenozoic volcanism or syn-rift extensional tectonics. It is suggested that the geothermal anomaly in the southern Jornada del Muerto (approx. 125 to approx. 95 mWm(-2) results from some type of mass movement-heat transfer mechanism operating in the crust just below the elastic layer. This conclusion is consistent with the geologic and geophysical data which describe a thin crust, apparently devoid of features indicative of extensional-tectonics in the upper part of the lastic crust.

  17. Modelling of coupled heat and moisture flows around a buried electrical cable

    Directory of Open Access Journals (Sweden)

    Eslami Hossein

    2016-01-01

    Full Text Available The admissible current within a buried electrical power cable is limited by the maximum allowed temperature of the cable (Joule effect. The thermal properties of the surrounding soil controls heat dissipation around the cable. The main focus of the study was to evaluate the coupled heat and moisture flow around such buried electrical cables. The heat dissipation of a buried power cable was simulated in the surrounding soil at unsteady conditions. The hydro-thermal coupling was modelled by taking into account the moisture flow of liquid water and vapour, and the heat flow in the soil by convection and advection. As the thermal vapour diffusion enhancement factor (η appears to be a key parameter, the sensitivity study of the coupled heat and moisture flow in the ground regarding this parameter was performed. The variations of the degree of saturation and the temperature of the surrounding soil were studied over 180 days of heating. The results showed that the moisture flow was mainly caused by the vapour transport under temperature gradients. These results emphasized the significant effect of the hydrothermal characteristics of surrounding soil. The radius of influence of the power cable was also evaluated.

  18. An experimental study on micro-scale flow boiling heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Tibirica, Cristiano Bigonha; Ribatski, Gherhardt [Universidade de Sao Paulo (USP), Sao Carlos, SP (Brazil). Escola de Engenharia. Dept. de Engenharia Mecanica

    2009-07-01

    In this paper, new experimental flow boiling heat transfer results in micro-scale tubes are presented. The experimental data were obtained in a horizontal 2.32 mm I.D. stainless steel tube with heating length of 464 mm, R134a as working fluid, mass velocities ranging from 50 to 600 kg/m{sup 2}s, heat flux from 5 to 55 kW/m{sup 2}, exit saturation temperatures of 22, 31 and 41 deg C, and vapor qualities from 0.05 to 0.98. Flow pattern characterization was also performed from images obtained by high speed filming. Heat transfer coefficient results from 2 to 14 kW/m{sup 2}K were measured. It was found that the heat transfer coefficient is a strong function of the saturation pressure, heat flux, mass velocity and vapor quality. The experimental data were compared against the following micro-scale flow boiling predictive methods from the literature: Saitoh et al., Kandlikar, Zhang et al. and Thome et al. Comparisons against these methods based on the data segregated according to flow patterns were also performed. Though not satisfactory, Saitoh et al. worked the best and was able of capturing most of the experimental heat transfer trends. (author)

  19. Effect of particle loading on heat transfer enhancement in a gas-solid suspension cross flow

    Institute of Scientific and Technical Information of China (English)

    周劲松; 骆仲泱; 高翔; 倪明江; 岑可法

    2002-01-01

    Heat transfer between gas-solid multiphase flow and tubes occurs in many industry processes, such as circulating fluidized bed process, pneumatic conveying process, chemical process, drying process, etc. (This paper focuses on the influence of the presence of particles on the heat transfer between a tube and gas-solid sus-pension. The presence of particles causes positive enhancement of heat transfer in the case of high solid loading ratio, but heat transfer reduction has been found for in the case of very low soliding ratio (Ms of less than 0.05 kg/kg). A usefial correlation ineorpomting solid lolling ratio, particle size and flow Reytmlds number was derived from experimental data. In addition, the κ-ε two-equation model and the Fluctuation-Spectrum-Random-Trajectory Model (FSRT Model) are used to simulate the flow field and heat transit of the gas-phase and the solid-phase, respectively. Through coupling of the two phases the model can predict the local and total heat transfer characteristics of tube in gas-solid cross flow. For the total heat transfer enhancement due to particles loading the model predictions agreed well wih experimental data.

  20. Experiments on Heat Transfer in a Thin Liquid Film Flowing Over a Rotating Disk

    Science.gov (United States)

    Sankaran, Subramanian (Technical Monitor); Ozar, B.; Cetegen, B. M.; Faghri, A.

    2004-01-01

    An experimental study of heat transfer into a thin liquid film on a rotating heated disk is described. Deionized water was introduced at the center of a heated. horizontal disk with a constant film thickness and uniform radial velocity. Radial distribution of the disk surface temperatures was measured using a thermocouple/slip ring arrangement. Experiments were performed for a range of liquid flow rates between 3.01pm and 15.01pm. The angular speed of the disk was varied from 0 rpm to 500 rpm. The local heat transfer coefficient was determined based on the heat flux supplied to the disk and the temperature difference between the measured disk surface temperature and the liquid entrance temperature onto the disk. The local heat transfer coefficient was seen to increase with increasing flow rate as well as increasing angular velocity of the disk. Effect of rotation on heat transfer was largest for the lower liquid flow rates with the effect gradually decreasing with increasing liquid flow rates. Semi-empirical correlations are presented in this study for the local and average Nusselt numbers.

  1. Parametric Studies on Buoyancy Induced Flow through Circular Pipes in Solar water heating system

    Directory of Open Access Journals (Sweden)

    Dr. S. V. Prayagi

    2011-01-01

    Full Text Available Solar energy is the primary source of energy for our planet. The average solar energy reaching the earth in the tropical zone is about 1kWh/m2 giving approximately 5 to 10 kWh/m2 per day. Increased utilization of solar energy in India would result in all around benefits, both in term of cleaner environment and monetary gain.The energy from the sun can be used for various purposes such as water heating, water distillation, refrigeration, drying, power generation etc. The present work deals with solar water heating system in particular. Performance of the solar collectors can be determined using the famous Hottel-Whillier-Bliss equation [1]. The analysis is simple for the forced convection situation, where the flow rate is artificially maintained constant to a desired value and the heat transfer coefficient can easily be predicted using the information available in the literature. However the natural convection situation it is very difficult to analyze as appropriate correlations for predicting the values of induced mass flow rate due to thermosiphon effect and the associated heat transfer coefficient are not available. The aim of the present investigation, therefore, is to establish correlations for heat transfer and flow characteristics for the buoyancy induced flow through inclined tubes in case of solar water heating system in particular. Considering the complexity of the problem, experimental approach is preferred. In order to produce required data, experiments were performed using inclined tubes of various lengths, diameters, inclinations, and different heat inputs.

  2. Convective heat transfer and flow characteristics of Cu-water nanofluid

    Institute of Scientific and Technical Information of China (English)

    LI; Qiang(李强); XUAN; Yimin(宣益民)

    2002-01-01

    An experimental system is built to investigate convective heat transfer and flow characteristics of the nanofluid in a tube. Both the convective heat transfer coefficient and friction factor of Cu-water nanofluid for the laminar and turbulent flow are measured. The effects of such factors as the volume fraction of suspended nanoparticles and the Reynolds number on the heat transfer and flow characteristics are discussed in detail. The experimental results show that the suspended nanoparticles remarkably increase the convective heat transfer coefficient of the base fluid and show that the friction factor of the sample nanofluid with the low volume fraction of nanoparticles is almost not changed. Compared with the base fluid, for example, the convective heat transfer coefficient is increased about 60% for the nanofluid with 2.0 vol% Cu nanoparticles at the same Reynolds number. Considering the factors affecting the convective heat transfer coefficient of the nano- fluid, a new convective heat transfer correlation for nanofluid under single-phase flows in tubes is established. Comparison between the experimental data and the calculated results indicate that the correlation describes correctly the energy transport of the nanofluid.

  3. Numerical investigation of fluid flow and heat transfer under high heat flux using rectangular micro-channels

    KAUST Repository

    Mansoor, Mohammad M.

    2012-02-01

    A 3D-conjugate numerical investigation was conducted to predict heat transfer characteristics in a rectangular cross-sectional micro-channel employing simultaneously developing single-phase flows. The numerical code was validated by comparison with previous experimental and numerical results for the same micro-channel dimensions and classical correlations based on conventional sized channels. High heat fluxes up to 130W/cm 2 were applied to investigate micro-channel thermal characteristics. The entire computational domain was discretized using a 120×160×100 grid for the micro-channel with an aspect ratio of (α=4.56) and examined for Reynolds numbers in the laminar range (Re 500-2000) using FLUENT. De-ionized water served as the cooling fluid while the micro-channel substrate used was made of copper. Validation results were found to be in good agreement with previous experimental and numerical data [1] with an average deviation of less than 4.2%. As the applied heat flux increased, an increase in heat transfer coefficient values was observed. Also, the Reynolds number required for transition from single-phase fluid to two-phase was found to increase. A correlation is proposed for the results of average Nusselt numbers for the heat transfer characteristics in micro-channels with simultaneously developing, single-phase flows. © 2011 Elsevier Ltd.

  4. Molecular dynamics study of solid-liquid heat transfer and passive liquid flow

    Science.gov (United States)

    Yesudasan Daisy, Sumith

    High heat flux removal is a challenging problem in boilers, electronics cooling, concentrated photovoltaic and other power conversion devices. Heat transfer by phase change is one of the most efficient mechanisms for removing heat from a solid surface. Futuristic electronic devices are expected to generate more than 1000 W/cm2 of heat. Despite the advancements in microscale and nanoscale manufacturing, the maximum passive heat flux removal has been 300 W/cm2 in pool boiling. Such limitations can be overcome by developing nanoscale thin-film evaporation based devices, which however require a better understanding of surface interactions and liquid vapor phase change process. Evaporation based passive flow is an inspiration from the transpiration process that happens in trees. If we can mimic this process and develop heat removal devices, then we can develop efficient cooling devices. The existing passive flow based cooling devices still needs improvement to meet the future demands. To improve the efficiency and capacity of these devices, we need to explore and quantify the passive flow happening at nanoscales. Experimental techniques have not advanced enough to study these fundamental phenomena at the nanoscale, an alternative method is to perform theoretical study at nanoscales. Molecular dynamics (MD) simulation is a widely accepted powerful tool for studying a range of fundamental and engineering problems. MD simulations can be utilized to study the passive flow mechanism and heat transfer due to it. To study passive flow using MD, apart from the conventional methods available in MD, we need to have methods to simulate the heat transfer between solid and liquid, local pressure, surface tension, density, temperature calculation methods, realistic boundary conditions, etc. Heat transfer between solid and fluids has been a challenging area in MD simulations, and has only been minimally explored (especially for a practical fluid like water). Conventionally, an

  5. Chemical reaction and heat source effects on MHD oscillatory flow in an irregular channel

    Directory of Open Access Journals (Sweden)

    P.V. Satya Narayana

    2016-12-01

    Full Text Available This paper investigates the effect of heat and mass transfer on MHD oscillatory flow in an asymmetric wavy channel with chemical reaction and heat source. The unsteadiness in the flow is due to an oscillatory pressure gradient across the ends of the channel. A magnetic field of uniform strength is applied in the direction perpendicular to the channel. However, the induced magnetic field is neglected due to the assumption of small magnetic Reynolds number. The temperature difference of the channel is also assumed high enough to induce heat transfer due to radiation. The governing equations are solved analytically by regular perturbation method. The analytical results are evaluated numerically and then are presented graphically to discuss the effects of different parameters entering into the problem. It is observed that the heat transport of a system is more increased in oscillatory flow than in ordinary conduction.

  6. Thermally determining flow and/or heat load distribution in parallel paths

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J.; Iyengar, Madhusudan K.; Parida, Pritish R.

    2017-08-01

    A method including obtaining calibration data for at least one sub-component in a heat transfer assembly, wherein the calibration data comprises at least one indication of coolant flow rate through the sub-component for a given surface temperature delta of the sub-component and a given heat load into said sub-component, determining a measured heat load into the sub-component, determining a measured surface temperature delta of the sub-component, and determining a coolant flow distribution in a first flow path comprising the sub-component from the calibration data according to the measured heat load and the measured surface temperature delta of the sub-component.

  7. The influence of flow maldistribution on the performance of inhomogeneous parallel plate heat exhangers

    DEFF Research Database (Denmark)

    Nielsen, Kaspar Kirstein; Engelbrecht, Kurt; Bahl, Christian R.H.

    2013-01-01

    The heat transfer performance of inhomogeneous parallel plate heat exchangers in transient operation is investigated using an established model. A performance parameter, denoted the Nusselt-scaling factor, is used as benchmark and calculated using a well-established single blow technique. A sample...... of 50 random stacks having equal average channel thicknesses with 20 channels each are used to provide a statistical base. The standard deviation of the stacks is varied as are the flow rate (Reynolds number) and the thermal conductivity of the solid heat exchanger material. It is found that the heat...... transfer performance of inhomogeneous stacks of parallel plates may be reduced significantly due to the maldistribution of the fluid flow compared to the ideal homogeneous case. The individual channels experience different flow velocities and this further induces an inter-channel thermal cross talk....

  8. Convective Heat Transfer Augmentation by Flexible fins in Laminar Channel Pulsating flow

    CERN Document Server

    Joshi, Rakshitha U; Bhardwaj, Rajneesh

    2015-01-01

    Fluid-structure interaction (FSI) of thin flexible fins coupled with convective heat transfer has applications in energy harvesting and in understanding functioning of several biological systems. We numerically investigate FSI of the thin flexible fins involving large-scale flow-induced deformation as a potential heat transfer enhancement technique. An in-house, strongly-coupled fluid-structure interaction (FSI) solver is employed in which flow and structure solvers are based on sharp-interface immersed boundary and finite element method, respectively. We consider twin flexible fins in a heated channel with laminar pulsating cross flow. The vortex ring past the fin sweep higher sources of vorticity generated on the channel walls out into the downstream - promoting the mixing of the fluid. The moving fin assists in convective mixing, augmenting convection in bulk and at the walls; and thereby reducing thermal boundary layer thickness and improving heat transfer at the channel walls. The thermal augmentation is...

  9. Thermally determining flow and/or heat load distribution in parallel paths

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J.; Iyengar, Madhusudan K.; Parida, Pritish R.

    2016-12-13

    A method including obtaining calibration data for at least one sub-component in a heat transfer assembly, wherein the calibration data comprises at least one indication of coolant flow rate through the sub-component for a given surface temperature delta of the sub-component and a given heat load into said sub-component, determining a measured heat load into the sub-component, determining a measured surface temperature delta of the sub-component, and determining a coolant flow distribution in a first flow path comprising the sub-component from the calibration data according to the measured heat load and the measured surface temperature delta of the sub-component.

  10. An experimental study of heat and momentum transfer in pipe flow of viscoelastic fluids

    Science.gov (United States)

    Ng, K. S.

    Heat transfer and pressure drop results are presented for pipe flow of aqueous solutions of polyacrylamide and polyethylene oxide in weight concentration of a few thousand parts per million. Experiments were conducted in two experimental set-ups. The first set-up consisted of two different diameter tubes. The turbulent flow hydrodynamic entry length was found to be 110 pipe diameters. Laminar friction factor data were in good agreement with correlations for purely viscous non-Newtonian fluids. The second set-up consisted of three different diameter tubes with heat transfer length-to-diameter ratio of 282, 489, and 648. The turbulent flow thermal entry length was found to be about 400 pipe diameters. The asymptotic dimensionless heat transfer coefficients were observed to be independent of pipe diameter, polymer molecular weight, and polymer concentration, suggesting the existence of a maximum heat transfer reduction asymptote.

  11. Measuring the Thermal Conductivities of Low Heat Conducting Disk Samples by Monitoring the Heat Flow

    Directory of Open Access Journals (Sweden)

    José A. Ibáñez-Mengual

    2017-02-01

    Full Text Available This article aims to establish an experimental procedure to measure heat transmission coefficients in low heat conductive materials. The newly developed model takes as starting point the application of Fourier’s law to a disk sample when a temperature gradient is established between its faces. The power of a heating element is determined as the heat transfer coefficient of the problem disk. Initially, a glass vessel containing water is placed in direct contact with the heating element; then, a problem plastic disk is placed between this element and the glass vessel, treating the set as a composite wall. Prior to the above the water equivalent of a calorimetric set (vessel + water + accessories and the thermal conductivity of the vessel must be determined. The thermal conductivity of the problem plastic disk sample is obtained for temperatures ranging from 30 to 70° C. The results reveal the existence of some type of structural transition for the problem material.

  12. Heat flow description during crystallization process of cast dispersive composites

    Directory of Open Access Journals (Sweden)

    Cholewa M.

    2007-01-01

    Full Text Available The aim of this work was to show possibilities of numerical simulation software, based on heat transfer model, commonly used in foundry industry in cast composite properties engineering. The main restriction in most of used software systems is lack of heat transfer, which may occur at composite creation. In this work the reinforcing particle morphology an size were expressed by one quantity – morphological modulus Mm and were examined for influence on heat transfer and conductivity up to the Newton’s and Fourier’s laws. The main restrictions for using Fourier’s model based software for composite engineering are shown. The way for crystallization control was presented including influence of morphology, transition zone and thermo-physical properties of components. Proposed methodology can be used for cast composite properties engineering in cases, where relative motion of components is negligible. In other cases heat transfer coefficient is justified only if the software used is based on Fourier’s model and the source code is accessible. Proposed assumptions create possibility for components selection verification in terms of technological and operating properties of cast composite. An example of such approach was shown in work [1, 23].

  13. Emissivity corrected infrared method for imaging anomalous structural heat flows

    Science.gov (United States)

    Del Grande, Nancy K.; Durbin, Philip F.; Dolan, Kenneth W.; Perkins, Dwight E.

    1995-01-01

    A method for detecting flaws in structures using dual band infrared radiation. Heat is applied to the structure being evaluated. The structure is scanned for two different wavelengths and data obtained in the form of images. Images are used to remove clutter to form a corrected image. The existence and nature of a flaw is determined by investigating a variety of features.

  14. An investigation of flow characteristics and critical heat flux in vertical upward round tube

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Prediction of critical heat flux (CHF) in annular flow is important for the safety of once- through steam generator and the reactor core under accident conditions. The dryout in annular flow occurs at the point where the film is depleted due to entrainment, deposition, and evaporation. The film thickness, film mass flow rate along axial distribution, and CHF are calculated in vertical upward round tube on the basis of a separated flow model of annular flow. The theoretical CHF values are higher than those derived from experimental data, with error being within 30%.

  15. Three dimensional Couette flow and heat transfer through a porous medium with variable permeability

    Institute of Scientific and Technical Information of China (English)

    CHAUDHARYR.C.; SHARMAPawanKumar

    2003-01-01

    This paper reports research on the effects of variations in injection velocity and permeability on the heat transfer and flow through a highly porous medium between two horizontal parallel plates situated at constant distance with constant suction by the upper plate.Due to this type of variation in injection velocity and in permeability the flow becomes three dimensional.The governing equstions are solved by adopting complex variable notations to obtain the expressions for the velocity and temperature field.The skin-friction along the main flow direction and rate of heat transfer are discussed with the help of graphs.

  16. MHD non-Newtonian micropolar fluid flow and heat transfer in channel with stretching walls

    Institute of Scientific and Technical Information of China (English)

    M. ASHRAF; N. JAMEEL; K. ALI

    2013-01-01

    A study is presented for magnetohydrodynamics (MHD) flow and heat trans-fer characteristics of a viscous incompressible electrically conducting micropolar fluid in a channel with stretching walls. The micropolar model introduced by Eringen is used to describe the working fluid. The transformed self similar ordinary differential equations together with the associated boundary conditions are solved numerically by an algorithm based on quasi-linearization and multilevel discretization. The effects of some physical parameters on the flow and heat transfer are discussed and presented through tables and graphs. The present investigations may be beneficial in the flow and thermal control of polymeric processing.

  17. Effect of swirl flow on heat transfer characteristics in a circular pipe

    Science.gov (United States)

    Siddique, Hossain; Hoque, Md. Shafkat Bin; Ali, Mohammad

    2016-07-01

    Swirl flow is of great stature in heat transfer enhancement and in numerous engineering applications. In the present numerical study, the swirl flow of water in a circular pipe is considered. Here the Reynolds Number is kept within 2000. The pipe contains stationary blades to produce the swirl flow. The blades are considered heat resistant. The three-dimensional Navier-Stokes equations for incompressible Newtonian fluid flow are used. The code is corroborated by comparing the simulation results with the established Hagen-Poiseuille law. The comparison is quite satisfactory and thus the code is used for present investigation. In this study, the heat transfer performance of the swirl flow is evaluated. Two cases are considered on the outer surface of the pipe: (i) Constant heat flux and (ii) Constant temperature. This investigation reveals that the swirl flow increases the mean outlet temperature in both cases. The effects of the vane angle, pipe length and diameter on heat transfer characteristics are also evaluated.

  18. Some effects of interface on fluid flow and heat transfer on micro- and nanoscale

    Institute of Scientific and Technical Information of China (English)

    LIANG XinGang

    2007-01-01

    The interfacial effects on flow and heat transfer on micro/nano scale are discussed in this paper. Different from bulk cases where interfaces can be simply treated as a boundary, the interfacial effects are not limited to the interface on a microscale but could extend into a significant, even the whole domain of the flow and heat transfer field when the characteristic size of the domain is close to the mean free path (MFP) of the carriers inside an object. Most of microscale thermal phenomena result from interfacial interactions. Any changes in the interactions between the object and boundary particles, such as the force between fluid and solid wall particles, microstructure of interfaces, could affect thermal properties, flow and heat transfer characteristics and hence change thermal conductivity, velocity and temperature profiles, friction coefficient and thermal radiative properties, etc. The properties of nano- structure or flow and heat transfer features of fluid in micro/nanostructures not only depend on themselves, but also on the interaction with the interface because the interface impact can go deep inside the flow. The same fluid, same channel geometry but different wall materials could have different flow and heat transport characteristics on microscale.

  19. Investigation on Characterizing Heated Pulsating Flows with Hot Wire Anemometers - A Hands-On Approach

    Directory of Open Access Journals (Sweden)

    Marius Alexandru PANAIT

    2014-06-01

    Full Text Available The pulsating heated flows are traditionally a difficult subject to treat with conventional hot wire or film methods. Special factors that complicate matters are flow reversal and non linear flow effects of vortices and wire probe wake disturbances on the heat transfer to the hot film or wire sensor in heated pulsating flows. The presence of these strongly nonlinear and unknown terms leads to great difficulties in calibration of hot film probes in this particular regime. The paper analyses the current state of matters in the field and reports a series of solutions that have been practically tested in a case of a high speed pulsated heated flow. Normally such measurements are made in a non-contact fashion using a LDV system or various visualization techniques but there have been recent attempts to use a constant temperature hot wire anemometer system (CTA.To obtain meaningful calibration for hot wire films in hot pulsating flows, a comparison system on other principles (LDV was used, as well as a specially designed nozzle to replace the calibrator unit that could not be operated with heated fluid due to structural integrity reasons. The method as described below works well for the expected speed range that could be generated using the special nozzle.

  20. Exact solutions for MHD flow of couple stress fluid with heat transfer

    Directory of Open Access Journals (Sweden)

    Najeeb Alam Khan

    2016-01-01

    Full Text Available This paper aims at presenting exact solutions for MHD flow of couple stress fluid with heat transfer. The governing partial differential equations (PDEs for an incompressible MHD flow of couple stress fluid are reduced to ordinary differential equations by employing wave parameter. The methodology is implemented for linearizing the flow equations without extra transformation and restrictive assumptions. Comparison is made with the result obtained previously.

  1. A study on the counter current and cocurrent annular flow critical heat flux under low flow conditions

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheol

    1998-02-15

    Empirical and phenomenological investigations have been performed for countercurrent and cocurrent annular flow critical heat fluxes(CHFs) under low flow conditions. The CHF characteristics on finned surfaces were also examined by experiments and analyses for finned and unfinned geometries. A new form of C{sub w}{sup 2} in the Wallis flooding correlation was proposed for a general use in predicting the flooding limited CHF at tubes, annuli and rectangular channels under zero and very low flow conditions. The suggested correlation showed reasonable predictions compared to the measured CHF with an root-mean-square(RMS) error of 18.8%. A physical model for the prediction of a CHF location at a zero inlet flow condition was improved to take into account entrainment from the liquid film and to extend the applicable range to subcooled inlet flow conditions. The improved model showed reasonable agreements with the Katto data, and provided details of the CHF mechanism due to flooding. It was analytically confirmed that the flooding is a triggering mechanism of a countercurrent annular flow CHF under zero and very low flow conditions. It was also revealed that the heat flux effect such as the nucleation induced entrainment in the liquid film should be considered for the analysis of a flooding limited CHF, especially in small L/D geometry. In addition, an attempt was made to predict CHF values by applying the improved model with predetermined CHF locations. The results showed that the predictions by the improved physical model agreed reasonably with the experimental data. Annular flow hydrodynamic models of Whalley, Levy and Katto, which were developed for high flow conditions, were compared with available low flow CHF data to make out the applicability of the models to low flow conditions. As a result, it was found that Katto model, which improved the fault of Whally and Levy models, could be applied to predict low flow CHF with some improvements although the model

  2. Heat flow characterization and baseline of sandstone using infra-red thermography

    Science.gov (United States)

    Ibrahim, Y.; Padmanabhan, E.; Ano, A. B.; Ismail, W.

    2016-11-01

    Infra-red thermography was applied to sandstone to characterize and obtain a baseline or a reference thermal image for sandstone. The sample was imaged at room temperature and then heated and imaged again at different time intervals. The thermal images and the optical gradient obtained were analyzed, calibrated, and equated to actual-temperature measured geothermal gradient under controlled heat flux. Heat flow propagation is not consistent in the first time intervals (below 25 minutes). However, after that, the difference in temperature in the distal part and the proximal parts to the heat source almost remained constant. In general, the heat flow could fit to a linear model that is directly proportional to time. The results can be useful when applied to borehole thermal imaging, as well as in thermal conductivity and geothermal gradient determination.

  3. Three-dimensional Oldroyd-B fluid flow with Cattaneo-Christov heat flux model

    Science.gov (United States)

    Shehzad, S. A.; Hayat, T.; Abbasi, F. M.; Javed, Tariq; Kutbi, M. A.

    2016-04-01

    The impact of Cattaneo-Christov heat flux in three-dimensional flow of an Oldroyd-B fluid over a bidirectional stretching surface is explored in this article. The boundary layer flow of an incompressible fluid is considered. Heat transfer analysis is discussed via the Cattaneo-Christov model of heat flux. Similarity transformations lead to the nonlinear ordinary differential systems. Convergent solutions of dimensionless velocities and temperature have been computed. Convergence analysis is presented graphically and numerically. The influence of physical parameters on the velocities and temperature are plotted and discussed. We observed that the values of temperature gradient are higher for the Cattaneo-Christov heat flux model when we compare it with the values obtained by the simple Fourier's law of heat conduction.

  4. Adaptive neuro-fuzzy modeling of transient heat transfer in circular duct air flow

    Energy Technology Data Exchange (ETDEWEB)

    Hasiloglu, Abdulsamet [Department of Electronics and Telecommunications Engineering, Engineering Faculty, Ataturk University, Erzurum (Turkey); Yilmaz, Mehmet; Comakli, Omer [Department of Mechanical Engineering, Engineering Faculty, Ataturk University, Erzurum (Turkey); Ekmekci, Ismail [Department of Mechanical Engineering, Engineering Faculty, Sakarya University, Sakarya (Turkey)

    2004-11-01

    The aim of this study is to demonstrate the usefulness of an adaptive neuro-fuzzy inference system (ANFIS) for the prediction of transient heat transfer. An ANFIS has been applied for the transient heat transfer in thermally and simultaneously developing circular duct flow, subjected to a sinusoidally varying inlet temperature. The experiments covered Reynolds numbers in the 2528{<=}Re{<=}4265 range and inlet heat input in the 0.01{<=}{beta}{<=}0.96 Hz frequency range. The accuracy of predictions and the adaptability of the ANFIS were examined, and good predictions were achieved for the temperature amplitudes of the transient heat transfer in thermally and simultaneously developing circular duct flow. The results show that the neuro-fuzzy can be used for modeling transient heat transfer in ducts. The results obtained with the ANFIS are also compared to those of a multiple linear regression and a neural network with a multi-layered feed-forward back-propagation algorithm. (authors)

  5. Analytical modeling for the heat transfer in sheared flows of nanofluids

    CERN Document Server

    Ferrari, Claudio; L'vov, Victor S; Procaccia, Itamar; Rudenko, Oleksii; Boonkkamp, J H M ten Thije; Toschi, Federico

    2012-01-01

    We developed a model for the enhancement of the heat flux by spherical and elongated nano- particles in sheared laminar flows of nano-fluids. Besides the heat flux carried by the nanoparticles the model accounts for the contribution of their rotation to the heat flux inside and outside the particles. The rotation of the nanoparticles has a twofold effect, it induces a fluid advection around the particle and it strongly influences the statistical distribution of particle orientations. These dynamical effects, which were not included in existing thermal models, are responsible for changing the thermal properties of flowing fluids as compared to quiescent fluids. The proposed model is strongly supported by extensive numerical simulations, demonstrating a potential increase of the heat flux far beyond the Maxwell-Garnet limit for the spherical nanoparticles. The road ahead which should lead towards robust predictive models of heat flux enhancement is discussed.

  6. Non-Radiative Step Facets in Semiconductor Nanowires.

    Science.gov (United States)

    Sanchez, Ana M; Zhang, Yunyan; Tait, Edward W; Hine, Nicholas D M; Liu, Huiyun; Beanland, Richard

    2017-03-24

    One of the main advantages of nanowires for functional applications is their high perfection, which results from surface image forces that act on line defects such as dislocations, rendering them unstable and driving them out of the crystal. Here we show that there is a class of linear defects that are stable in nanowires, with no long-range strain field or dislocation character. In zinc-blende semiconductors, they take the form of Ʃ3 (112) facets with heights constrained to be a multiple of three {111} monolayers. Density functional theory calculations show that they act as non-radiative recombination centres and have deleterious effects on nanowire properties. We present experimental observations of these defects on twin boundaries and twins that terminate inside GaAsP nanowires and find that they are indeed always multiples of three monolayers in height. Strategies to use the three-monolayer rule during growth to prevent their formation are discussed.

  7. Dissipation Effects on MHD Nonlinear Flow and Heat Transfer Past a Porous Surface with Prescribed Heat Flux

    Directory of Open Access Journals (Sweden)

    S.P. Anjali Devi

    2010-01-01

    Full Text Available Viscous and Joule dissipation effects are considered on MHD nonlinear flow and heat transfer past a stretching porous surface embedded in a porous medium under a transverse magnetic field. Analytical solutions of highly nonlinear momentum equation and confluent hypergeometric similarity solution of heat transfer equations in the case when the plate stretches with velocity varying linearly with distance are obtained. The effect of various parameters like suction parameter, Prandtl number, Magnetic parameter, and Eckert number entering into the velocity field, temperature distribution and skin friction co-efficient at the wall are discussed with the aid of graphs.

  8. Mixed convection flow over a stretching porous wedge with Newtonian heating in the presence of heat generation or absorption

    Science.gov (United States)

    Ashraf, M.; Narahari, Marneni; Muthuvalu, Mohana Sundaram

    2016-11-01

    Time independent mixed convective boundary layer flow of a viscous fluid over a porous stretching wedge is investigated analytically. The porous wedge is subjected to Newtonian heating in the existence of heat generation /absorption. Employing non-dimensional transformations the governing PDE's converted to nonlinear ODE's which are further solved by using homotopy analysis method. The convergence of the solution is properly checked and the effects of various involved parameters on velocity and temperature distributions are illustrated through graphs. The reliability and effectiveness of HAM have been verified by comparing the present analytical results with existing numerical results for skin-friction coefficient. The results are found to be in good agreement.

  9. Convective heat transfer for incompressible laminar gas flow in micropassage with constant wall temperature

    Institute of Scientific and Technical Information of China (English)

    An; Gang; (

    2001-01-01

    [1]Tuckermann, D. B., Pease, R. F., Optimized convective cooling using micromachined structure, J. Electro-Chemical Society, 1982, 129(3): 98c.[2]Wu Peiyi, Little, W. A., Measurement of friction factor for the flow of gases in very fine channel used for microminiature Joule-Thomson refrigerators, Cryogenics, 1983, 23(5): 273.[3]Wu Peiyi, Little, W. A., Measurement of the heat transfer characteristics of gas flow in fine channel heat exchangers used for microminiature refrigerators, Cryogenics, 1984, 24(8): 415.[4]Choi, B., Barron, R. F., Warrington, R. O., Fluid flow and heat transfer in microtubes, ASME DSC, 1991, 32: 123.[5]Pfahler, J., Harley, J., Bua, H. et al., Gas and liquid flow in small channel, ASME DSC, 1991, 32: 49.[6]Beskok, A., Karniadakis, G. E., Simulation of slip-flow in complex micro-geometries, ASME DSC, 1992, 40: 355.[7]Mohiuddin, M. G., Li Dongqing, Dale, J. D., Heat transfer and fluid flow in microchannels, Int. J. Heat and Mass Transfer, 1997, 40(13): 3079.[8]Li, J. M., Wang, B. X., Peng, X. F., The wall effect for laminar flow through microtube, in Int. Center for Heat and Mass Transfer (ICHMT) Symposium on Molecular and Microscale Heat Transfer in Material Processing and Other Application Yokohama, Japan, (eds. Tanasawa, I., Nishio, S.), New York: Begell House,1996, 55-65.[9]Li, J. M., Wang, B. X., Peng, X. F., Laminar flow of gas through extremely narrow parallel plates, in Heat Transfer and Technology 1996, Proc. Fourth ISHT (ed. Wang, B. X.), Beijing: Higher Education Press, 1996, 318-322.[10]Li, J. M., Wang, B. X., Peng, X. F., Wall effect of gas laminar heat transfer in microtubes, Journal of Engineering Thermophysics (in Chinese), 1998, 19(5): 596.[11]Li, J. M., Wang, B. X., Peng, X. F., Laminar heat transfer of gas in microchannels between two paralled plates, Journal of Engineering Thermophysics (in Chinese), 1999, 20(2): 194.[12]Tao, W. Q., Numerical Heat Transfer (in Chinese), Xi

  10. Using the heat flow plate method for determining thermal conductivity of building materials

    Science.gov (United States)

    Flori, M.; Puţan, V.; Vîlceanu, L.

    2017-01-01

    The heat flow plate method is used to determine thermal conductivity of a building material sample made of Rohacell (insulating foam). Experimental technique consists in placing the sample with a reference material on top (polystyrene sample) in a calorimetric chamber and heating from underside. Considering that the heat flux which passes through the two layers is constant and knowing thermal conductivity of the reference material, the sample thermal conductivity is determined. The temperature difference between the two opposite sample’s sides is recorded only when the steady state is achieved (constant heat flux).

  11. Fluid flow and heat transfer investigation of pebble bed reactors using mesh-adaptive LES

    Energy Technology Data Exchange (ETDEWEB)

    Pavlidis, Dimitrios; Lathouwers, Danny, E-mail: d.lathouwers@tudelft.nl

    2013-11-15

    The very high temperature reactor is one of the designs currently being considered for nuclear power generation. One its variants is the pebble bed reactor in which the coolant passes through complex geometries (pores) at high Reynolds numbers. A computational fluid dynamics model with anisotropic mesh adaptivity is used to investigate coolant flow and heat transfer in such reactors. A novel method for implicitly incorporating solid boundaries based on multi-fluid flow modelling is adopted. The resulting model is able to resolve and simulate flow and heat transfer in randomly packed beds, regardless of the actual geometry, starting off with arbitrarily coarse meshes. The model is initially evaluated using an orderly stacked square channel of channel-height-to-particle diameter ratio of unity for a range of Reynolds numbers. The model is then applied to the face-centred cubical geometry. coolant flow and heat transfer patterns are investigated.

  12. Heat transfer effects on the stability of low speed plane Couette-Poiseuille flow

    Energy Technology Data Exchange (ETDEWEB)

    Oezgen, Serkan [Middle East Technical University, Department of Aerospace Engineering, Ankara (Turkey); Dursunkaya, Zafer [Middle East Technical University, Department of Mechanical Engineering, Ankara (Turkey); Ebrinc, Ali A. [FORD Otosan, Kocaeli (Turkey)

    2007-10-15

    The stability problem of low-speed plane Couette-Poiseuille flow of air under heat transfer effects is solved numerically using the linear stability theory. Stability equations obtained from two-dimensional equations of motion and their boundary conditions result in an eigenvalue problem that is solved using an efficient shoot-search technique. Variable fluid properties are accounted for both in the basic flow and the perturbation (stability) equations. A parametric study is performed in order to assess the roles of moving wall velocity and heat transfer. It is found that the moving wall velocity and the location of the critical layers play decisive roles in the instability mechanism. The flow becomes unconditionally stable whenever the moving wall velocity exceeds half of the maximum velocity in the channel. With wall heating and Mach number effects included, the flow is stabilized. (orig.)

  13. Non-sinusoidal waveform effects on heat transfer performance in pulsating pipe flow

    Directory of Open Access Journals (Sweden)

    R. Roslan

    2016-12-01

    Full Text Available In the present paper, an unsteady motion of fluid flow in a pulsating pipe is studied to determine the effect of non-sinusoidal waveforms on the heat transfer performance. Three non-sinusoidal waveforms, namely sawtooth, square and triangular waveforms have been considered. Explicit analytical expressions for a periodic laminar flow describing the flow and heat transfer at small and large times with sawtooth and square pressure waveforms have been derived using Bessel transform technique. The heat transfer performance of periodic flow at sawtooth and square pressure waveforms has been compared with the published result for triangular waveform [1]. The temperature performance for a triangular waveform pressure is very different from the sawtooth and square pressure waveforms.

  14. LARGE EDDY SIMULATION OF FREE SURFACE TURBULENT CHANNEL FLOW WITH HEAT TRANSFER

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    In this paper, the Large Eddy Simulation (LES) was used to study the free-surface turbulent channel flow with passive heat transfer. The three-dimensional filtered incompressible Navier-Stokes equations and energy equation were numerically solved with dynamic Subgrid Scale (SGS) models for modeling turbulent stresses and heat flux. To compare the turbulent behavior of the free-surface and two-walled channel flows, the LES of two-walled turbulent channel flow was performed. The statistical quantities and flow structures of the free-surface turbulence with heat transfer in the vicinity of the free-surface were investigated. The results are also in good agreement with theoretical analysis and available results by Direct Numerical Simulation (DNS).

  15. Parallelization of a coupled immersed boundary and lattice Boltzmann method for fluid and heat flow

    Science.gov (United States)

    Kasparek, Andrzej; Łapka, Piotr

    2017-07-01

    The paper presents first approach to the GPU-based parallelization of the coupled Immersed Boundary and Lattice Boltzmann Method. The proposed numerical simulator deals with fluid and heat flow in a domains with complex internal boundaries using Cartesian grid. The solution algorithm was parallelized with the aid of the CUDA architecture. Several heat and fluid flow problems, i.e., heated lid-driven flow and laminar natural convection in square domains without internal obstacles and isothermal flow past stationary cylinder were investigated. Satisfactory accelerations of the solution times were obtained for problems without internal boundaries. For test case with internal boundaries decrease in the parallel computing efficiency was observed as a results of numerical handling of the internal boundaries.

  16. Surface heat transfer and flow properties of vortex arrays induced artificially and from centrifugal instabilities

    Science.gov (United States)

    Subramanian, C. S.; Ligrani, P. M.; Tuzzolo, M. F.

    1992-01-01

    The paper presents and compares fluid-flow and heat transfer properties from artificially induced vortices in a flat-plate turbulent boundary layer and naturally occurring vortices due to centrifugal instabilities in a curved-channel laminar flow. Pairs and arrays of vortices are artificially induced by placing half-delta wings on the plate surface. With both arrays and pairs of vortices, streamwise velocities and total pressures are high, and surface heat transfer is locally augmented in vortex downwash regions. In contrast to vortices in the arrays vortices in the pairs tend to move in the streamwise direction with significant divergence (when the common flow between pair is toward the wall) or convergence (when the common flow between pair is away from the wall). The vortices in the arrays cause maximum peak-to-peak heat transfer variations of up to 12 percent of local spanwise-averaged values for initial vortex spacings between 1 to 2.5 generator heights.

  17. Distribution characteristics of terrestrial heat flow density in Jiyang depression of Shengli Oilfield, East China

    Institute of Scientific and Technical Information of China (English)

    GONG Yuling; WANG Liangshu; LIU Shaowen; LI Cheng; HAN Yongbing; LI Hua; LIU Bo; CAI Jingong

    2004-01-01

    Based on the geo-temperature data of 13 systematically continuous temperature log curves and 700 testing oil boreholes in Jiyang depression, Shengli Oilfield, and the measured thermal conductivities of 47 rock samples, the terrestrial heat flow densities of 114 boreholes of Jiyang depression and its surrounding areas are determined, including 13 of those data derived from systemically continuous temperature logging. The results show that Jiyang depression has a relatively high background heat flow with an average value (65.8 ± 5.4) mW/m2. The lateral variation of heat flow in basin has negative correlation with basement depth. Moreover, heat flow of uplift areas with shallower basement is high, so are those of regions with volcanic rocks, and those of depression areas with deep basement are relatively low. The heat flow densities of different structural units of Jiyang depression can be summarized as follows: The average heat flow value of Zhanhua sag is (67.4 ± 5.3) mW/m2, higher than that of the whole basin, that of Dongying sag is (66.0 ± 6.1) mW/m2, and that of Chezhen sag is (65.1 ± 3.7) mW/m2. It is apparent that these latter two values are approximate to the average value of the whole Jiyang depression,while the average value of Huimin sag is (63.6±5.0) mW/m2, lower than that of the whole basin. In fact, the basement depth and the distribution framework of uplift and depression areas are all controlled by the process of lithosphere extension. In addition, the distribution of volcanic rocks in basin is also relatively close to this extension geodynamic process. In summary, the distribution characteristics of terrestrial heat flow of Jiyang depression is determined by the Cenozoic tectono-thermal events of this region.

  18. Heat transfer and flow analysis of nanofluid flow between parallel plates in presence of variable magnetic field using HPM

    Energy Technology Data Exchange (ETDEWEB)

    Hatami, M., E-mail: m.hatami@tue.nl [Esfarayen University of Technology, Mechanical Engineering Department, Esfarayen, North Khorasan (Iran, Islamic Republic of); Jing, Dengwei; Song, Dongxing [International Research Center for Renewable Energy, State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi' an 710049 (China); Sheikholeslami, M.; Ganji, D.D. [Department of Mechanical Engineering, Babol University of Technology, Babol (Iran, Islamic Republic of)

    2015-12-15

    In this study, effect of variable magnetic field on nanofluid flow and heat transfer analysis between two parallel disks is investigated. By using the appropriate transformation for the velocity, temperature and concentration, the basic equations governing the flow, heat and mass transfer were reduced to a set of ordinary differential equations. These equations subjected to the associated boundary conditions were solved analytically using Homotopy perturbation method. The analytical investigation is carried out for different governing parameters namely: squeeze number, suction parameter, Hartmann number, Brownian motion parameter, thermophrotic parameter and Lewis number. Results show that Nusselt number has direct relationship with Brownian motion parameter and thermophrotic parameter but it is a decreasing function of squeeze number, suction parameter, Hartmann number and Lewis number. - Highlights: • Heat and mass transfer of nanofluids between parallel plates investigated. • A variable magnetic field is applied on the plates. • Governing equations are solved analytically. • Effects of physical parameters are discussed on the Nusselt number.

  19. Dimensioning of ducts for maximal volumetric heat transfer taking both laminar and turbulent flow possibilities into consideration

    Science.gov (United States)

    Yilmaz, Alper

    2015-04-01

    It is intended to design compact heat exchangers which can transfer high heat flow for a given volume and temperature difference with high efficiency. This work presents the optimal design of heat exchangers for a given length or hydraulic diameter with a constraint of a certain pressure loss and constant wall temperature. Both volumetric heat transfer and heat transfer efficiency are taken into consideration for the design in laminar or turbulent flow regions. Equations are derived which easily enable optimal design for all shapes of ducts and for all Pr numbers. It is found that optimum conditions for turbulent flow is possible for all duct hydraulic diameters; however, it is possible to have optimum conditions till a certain dimensionless duct hydraulic diameter for laminar flow. Besides maximal volumetric heat flow, heat transfer efficiency should be taken into consideration in turbulent flow for optimum design.

  20. Impact of wall hydrophobicity on condensation flow and heat transfer in silicon microchannels

    Science.gov (United States)

    Fang, Chen; Steinbrenner, Julie E.; Wang, Fu-Min; Goodson, Kenneth E.

    2010-04-01

    While microchannel condensation has been the subject of several recent studies, the critical impact of wall hydrophobicity on the microchannel condensation flow has received very little attention. The paper experimentally studies steam condensation in a silicon microchannel 286 µm in hydraulic diameter with three different wall hydrophobicities. It is found that the channel surface wettability has a significant impact on the flow pattern, pressure drop and heat transfer characteristic. Spatial flow pattern transition is observed in both hydrophobic and hydrophilic channels. In the hydrophobic channel, the transition from dropwise/slugwise flow to plug flow is induced by the slug instability. In the hydrophilic channel, the flow transition is characterized by the periodic bubble detachment, a process in which pressure evolution is found important. Local temperature measurement is conducted and heat flux distribution in the microchannel is reconstructed. For the same inlet vapor flux and temperature, the hydrophobic microchannel yields higher heat transfer rate and pressure drop compared to the hydrophilic channel. The difference is attributed to the distinction in flow pattern and heat transfer mechanism dictated by the channel hydrophobicity. This study highlights the importance of the channel hydrophobicity control for the optimization of the microchannel condenser.

  1. The Effects of Vortex Generator Types on Heat Transfer and Flow Structure in a Rectangular Duct Flows

    Directory of Open Access Journals (Sweden)

    Laith J.H

    2008-01-01

    Full Text Available In this numerical study a detailed evaluation of the heat transfer characteristics and flow structure in a laminar and turbulent flow through a rectangular channel containing built-in of different type vortex generator has been a accomplished in a range of Reynolds number between 500 and 100,000.A modified version of ESCEAT code has been used to solve Navier-Stokes and energy equations. The purpose of this paper is to present numerical comparisons in terms of temperature, Nusselt number and flow patterns on several configurations of longitudinal vortex generator including new five cases. The structures of heat and flow were studied, using iso-contours of velocity components, vortices, temperature and Nusselt number. This study shows that the predicted structures of fluid flow, temperature fields and Nusselt number variation are strongly affected by the presence of the turbulators. Staggered arrangement gains high Nusselt number, also the lower and upper arrangements have higher Nusselt number than plane duct. High Reynolds number (higher air inlet velocity will enhance the Nusselt number. Increase in ribs height will enhance the heat transfer as it works as surface area and turbulator at the same time.

  2. Thermodynamic coupling of heat and matter flows in near-field regions of nuclear waste repositories

    Energy Technology Data Exchange (ETDEWEB)

    Carnahan, C.L.

    1983-11-01

    In near-field regions of nuclear waste repositories, thermodynamically coupled flows of heat and matter can occur in addition to the independent flows in the presence of gradients of temperature, hydraulic potential, and composition. The following coupled effects can occur: thermal osmosis, thermal diffusion, chemical osmosis, thermal filtration, diffusion thermal effect, ultrafiltration, and coupled diffusion. Flows of heat and matter associated with these effects can modify the flows predictable from the direct effects, which are expressed by Fourier's law, Darcy's law, and Fick's law. The coupled effects can be treated quantitatively together with the direct effects by the methods of the thermodynamics of irreversible processes. The extent of departure of fully coupled flows from predictions based only on consideration of direct effects depends on the strengths of the gradients driving flows, and may be significant at early times in backfills and in near-field geologic environments of repositories. Approximate calculations using data from the literature and reasonable assumptions of repository conditions indicate that thermal-osmotic and chemical-osmotic flows of water in semipermeable backfills may exceed Darcian flows by two to three orders of magnitude, while flows of solutes may be reduced greatly by ultrafiltration and chemical osmosis, relative to the flows predicted by advection and diffusion alone. In permeable materials, thermal diffusion may contribute to solute flows to a smaller, but still significant, extent.

  3. Analytical study of flow and heat transfer in an annular porous medium subject to asymmetrical heat fluxes

    Science.gov (United States)

    Xu, Huijin; Zhao, Changying; Vafai, Kambiz

    2017-08-01

    Fully developed forced convective heat transfer in an annulus filled with a porous medium subject to asymmetrical heating is investigated analytically with different models in this work. The classic Darcy and Brinkman models were employed for the fluid flow, while the local thermal equilibrium (LTE) and the local thermal non-equilibrium (LTNE) models were employed to describe the heat transfer process in porous media. An analytical model based on fin theory was also employed for analyzing this problem. Exact solutions with Darcy-LTNE, Darcy-LTE, Brinkman-LTNE, Brinkman-LTE, and the fin models were obtained. Among these solutions, the Brinkman-LTNE solution can be treated as the benchmark, as it is a complete model, which covers the effect of viscous force near the solid wall and the temperature difference between the solid and fluid phases. The basic parameters that affect the velocity and temperature fields were analyzed in depth. The velocity and temperature profiles with these different models were also presented. The effects of some critical parameters on thermal performance of asymmetrically heated annulus fitted with a porous medium were discussed. The cited different analytical models were compared in detail with each other. The critical heat flux (HF) ratios for the inner and outer walls were presented in terms of a Nu- ξ curve for the five models. These solutions were developed for an asymmetrically heated annular channel filled with a porous medium, which can predict the thermal performance within a wide range of radii and HF ratios.

  4. Heat and mass transfer in two-phase flow motion in minichannel under variable heating

    Directory of Open Access Journals (Sweden)

    Chachilo Evgenii S.

    2014-01-01

    Full Text Available Experimental studying the effect of temperature on evaporation dynamics of the stationary horizontal liquid layer is presented. The average evaporation flow rate of liquid layer (ethanol by the gas flow (air has been calculated using two independent methods. The dependence of the evaporation flow rate from the temperature has been obtained. According to the analysis of the results it was found that the dependence is nonlinear and described by an exponential function.

  5. Methodology of heat transfer and flow resistance measurement for matrices of rotating regenerative heat exchangers

    National Research Council Canada - National Science Library

    Dariusz Butrymowicz; Jarosław Karwacki; Roman Kwidziński; Kamil Śmierciew; Jerzy Gagan; Tomasz Przybyliński; Teodor Skiepko; Marek Łapin

    2016-01-01

    The theoretical basis for the indirect measurement approach of mean heat transfer coefficient for the packed bed based on the modified single blow technique was presented and discussed in the paper...

  6. Heat transfer analysis for magnetohydrodynamics axisymmetric flow between stretching disks in the presence of viscous dissipation and Joule heating

    Directory of Open Access Journals (Sweden)

    N. Khan

    2015-05-01

    Full Text Available The investigation of heat transfer analysis on steady MHD axi-symmetric flow between two infinite stretching disks in the presence of viscous dissipation and Joule heating is basic objective of this paper. Attention has been focused to acquire the similarity solutions of the equations governing the flow and thermal fields. The transformed boundary value problem is solved analytically using homotopy analysis method. The series solutions are developed and the convergence of these solutions is explicitly discussed. The analytical expressions for fluid velocity, pressure and temperature are constructed and analyzed for various set of parameter values. The numerical values for skin friction coefficient and the Nusselt number are presented in tabular form. Particular attention is given to the variations of Prandtl and Eckert numbers. We examined that the dimensionless temperature field is enhanced when we increase the values of Eckert number and Prandtl number.

  7. Regional Heat Flow Map and the Continental Thermal Isostasy Understanding of México

    Science.gov (United States)

    Espinoza-Ojeda, O. M.; Harris, R. N.

    2014-12-01

    The first heat flow values made in Mexico were reported by Von Herzen [Science, 1963] for the marine environment and Smith [EPSL, 1974] for the continent. Since that time the number of measurements has increased greatly but are mostly from oil and gas exploration and in and around geothermal areas. We have compiled published values of conductive heat flow for Mexico and the Gulf of California to generate a new regional heat flow map consisting of 261 values. In addition to those original values, published heat flow sources include, Lee and Henyey [JGR, 1975], Lawver and Williams [JGR, 1979] Smith et al. [JGR, 1979], Lachenbruch et al. [JGR, 1985], and Ziagos et al. [JGR, 1985]. Although the geographic distribution is uneven, heat flow data are present in each of the eight main tectonic provinces. Our new compilation indicates relatively high regional heat flow averages in the Gulf Extensional Province (n=114, 92±22 mW/m2) and Mexican Basin and Range (n=21, 82±20 mW/m2) and are consistent with geologic estimates of extension. Lower regional averages are found in the Baja California Microplate (n=91, 75±19 mW/m2), the Sierra Madre Occidental (n=9, 75±12 mW/m2), the Sierra Madre Oriental (n=4, 68±15 mW/m2) and Mesa Central (n=X 77±23 mW/m2). In contrast low and variable heat flow value characterize the forearc region of the Middle America Trench (n=6, 35±16 mW/m2). A higher mean heat flow is associated with the Trans-Mexican Volcanic Belt (n=6, 78±26 mW/m2). Continental elevation results from a combination of buoyancy (i.e. compositional and thermal) and geodynamic forces. We combine these regional heat flow values with estimates of crustal thickness and density for each tectonic province and compute the thermal and compositional buoyancy following the approach of Hasterok and Chapman [JGR, 2007a,b]. We find that within uncertainties most provinces lie near the theoretical isostatic relationship with the exception of the Mesa Central and Sierra Madre del Sur

  8. How the propagation of heat-flux modulations triggers E × B flow pattern formation.

    Science.gov (United States)

    Kosuga, Y; Diamond, P H; Gürcan, O D

    2013-03-08

    We propose a novel mechanism to describe E×B flow pattern formation based upon the dynamics of propagation of heat-flux modulations. The E × B flows of interest are staircases, which are quasiregular patterns of strong, localized shear layers and profile corrugations interspersed between regions of avalanching. An analogy of staircase formation to jam formation in traffic flow is used to develop an extended model of heat avalanche dynamics. The extension includes a flux response time, during which the instantaneous heat flux relaxes to the mean heat flux, determined by symmetry constraints. The response time introduced here is the counterpart of the drivers' response time in traffic, during which drivers adjust their speed to match the background traffic flow. The finite response time causes the growth of mesoscale temperature perturbations, which evolve to form profile corrugations. The length scale associated with the maximum growth rate scales as Δ(2) ~ (v(thi)/λT(i))ρ(i)sqrt[χ(neo)τ], where λT(i) is a typical heat pulse speed, χ(neo) is the neoclassical thermal diffusivity, and τ is the response time of the heat flux. The connection between the scale length Δ(2) and the staircase interstep scale is discussed.

  9. Effect of particle loading on heat transfer enhancement in a gas-solid suspension cross flow

    Institute of Scientific and Technical Information of China (English)

    周劲松; 骆仲泱; 高翔; 倪明江; 岑可法

    2002-01-01

    Heat transfer between gas-solid multiphase flow and tubes occurs in m a ny industry processes, such as circulating fluidized bed process, pneumatic conv eying process, chemical process, drying process, etc. This paper focuses on the influence of the presence of particles on the heat transfer between a tube and g as-solid suspension. The presence of particles causes positive enhancement of h e at transfer in the case of high solid loading ratio, but heat transfer reduction has been found for in the case of very low solid loading ratio (Ms of les s than 0.05 kg/kg). A useful correlation incorporating solid loading ratio, particle s ize and flow Reynolds number was derived from experimental data. In addition, th e k-ε two-equation model and the Fluctuation-Spectrum- Random-Trajecto ry Model ( FSRT Model) are used to simulate the flow field and heat transfer of the gas-ph a se and the solid-phase, respectively. Through coupling of the two phases the mo d el can predict the local and total heat transfer characteristics of tube in gas - solid cross flow. For the total heat transfer enhancement due to particles loadi ng the model predictions agreed well with experimental data.

  10. Heat transfer in nonequilibrium boundary layer flow over a partly catalytic wall

    Science.gov (United States)

    Wang, Zhi-Hui

    2016-11-01

    Surface catalysis has a huge influence on the aeroheating performance of hypersonic vehicles. For the reentry flow problem of a traditional blunt vehicle, it is reasonable to assume a frozen boundary layer surrounding the vehicles' nose, and the catalytic heating can be decoupled with the heat conduction. However, when considering a hypersonic cruise vehicle flying in the medium-density near space, the boundary layer flow around its sharp leading-edge is likely to be nonequilibrium rather than frozen due to rarefied gas effects. As a result, there will be a competition between the heat conduction and the catalytic heating. In this paper, the theoretical modeling and the direct simulation Monte Carlo (DSMC) method are employed to study the corresponding rarefied nonequilibrium flow and heat transfer phenomena near the leading edge of the near space hypersonic vehicles. It is found that even under identical rarefication degree, the nonequilibrium degree of the flow and the corresponding heat transfer performance of the sharp leading edges could be different from that of the big blunt noses. A generalized model is preliminarily proposed to describe and to evaluate the competitive effects between the homogeneous recombination of atoms inside the nonequilibrium boundary layer and the heterogeneous recombination of atoms on the catalytic wall surface. The introduced nonequilibrium criterion and the analytical formula are validated and calibrated by the DSMC results, and the physical mechanism is discussed.

  11. Development of a compact laminar flow heat exchanger with stainless steel micro-tubes

    Science.gov (United States)

    Saji, N.; Nagai, S.; Tsuchiya, K.; Asakura, H.; Obata, M.

    2001-05-01

    The present paper describes the design concept and manufacturing of a new compact laminar flow heat exchanger with stainless-steel micro-tubes for helium refrigerators. In the temperature range of less than 20 K, aluminum plate fin type heat exchangers exhibit a remarkable fall of performance characteristics as a compact heat exchanger. We presented in a previous paper that some compact heat exchangers with good performance in the temperature range of less than 4 K are required for a subcooled He II refrigerator cycle to be worked with 3He turbo-compressors (F. Doty, et al., A new look at the closed brayton cycle, Proceedings, IECEC-90 Reno, NV, 1991, p. 116). For this requirement, we developed a micro-tube strip counter flow type heat exchanger, which consists of 12 elements with a total of 4800 stainless steel micro-tubes. Each element is formed with 400 tubes and a newly developed vacuum brazing method was applied for the bonding to the side plate. Each tube has an inner diameter of 0.5 mm, an outer diameter of 0.7 mm and is 310 mm long. We developed a cladding plate with two layers of gold brazing sheet sandwiched inside. In aerodynamic and thermal design of the element, the laminar flow conditions were adopted for the flows of inner and outer tubes to keep a high heat transfer rate and a low pressure loss.

  12. Two-phase flow and boiling heat transfer in two vertical narrow annuli

    Energy Technology Data Exchange (ETDEWEB)

    Peng Changhong [Department of Nuclear and Thermal Power Engineering, Xi' an Jiaotong University, Xian 710049 (China)]. E-mail: pxm321@163.com; Guo Yun [Department of Nuclear and Thermal Power Engineering, Xi' an Jiaotong University, Xian 710049 (China); Qiu Suizheng [Department of Nuclear and Thermal Power Engineering, Xi' an Jiaotong University, Xian 710049 (China); Jia Dounan [Department of Nuclear and Thermal Power Engineering, Xi' an Jiaotong University, Xian 710049 (China); Nie Changhua [Nuclear Power Institute of China, Chengdu 610041 (China)

    2005-07-01

    Experimental study associated with two-phase flow and heat transfer during flow boiling in two vertical narrow annuli has been conducted. The parameters examined were: mass flux from 38.8 to 163.1 kg/m{sup 2} s; heat flux from 4.9 to 50.7 kW/m{sup 2} for inside tube and from 4.2 to 78.8 kW/m{sup 2} for outside tube; equilibrium mass quality from 0.02 to 0.88; system pressure from 1.5 to 6.0 MPa. It was found that the boiling heat transfer was strongly influenced by heat flux, while the effect of mass velocity and mass quality were not very significant. This suggested that the boiling heat transfer was mainly via nucleate boiling. The data were used to develop a new correlation for boiling heat transfer in the narrow annuli. In the two-phase flow study, the comparison with the correlation of Chisholm [Chisholm, D., 1967. A theoretical basis for the Lockhart-Martinelli correlation for two-phase flow. Int. J. Heat Mass Transfer 10, 1767-1778] and Mishima and Hibiki [Mishima, K., Hibiki, T., 1996. Some characteristics of air-water two-phase flow in small diameter vertical tubes. Int. J. Multiphase Flow 22, 703-712] indicated that the existing correlations could not predict the two-phase multiplier in the narrow annuli well. Based on the experimental data, a new correlation was developed.

  13. Heat and mass transfer in magnetohydrodynamic flow of micropolar fluid on a circular cylinder with uniform heat and mass flux

    CERN Document Server

    Mansour, M A; El-Kabeir, S M

    2000-01-01

    Steady laminar boundary layer analysis of heat and mass transfer characteristics in magnetohydrodynamic (MHD) flow of a micropolar fluid on a circular cylinder maintained at uniform heat and mass flux has been conducted. The solution of the energy equation inside the boundary layer is obtained as a power series of the distance measured along the surface from the front stagnation point of the cylinder. The results of dimensionless temperature, Nusselt number, wall shear stress, wall couple stress and Sherwood number have been presented graphically for various values of the material parameters. The results indicate that the micropolar fluids display a reduction in drag as well as heat transfer rate when compared with Newtonian fluids.

  14. Heat flow, heat generation and crustal thermal structure of the northern block of the South Indian Craton

    Science.gov (United States)

    Gupta, Mohan L.; Sharma, S. R.; Sundar, A.

    1988-01-01

    Heat flow values and heat generation data calculated from the concentration of heat producing radioactive elements, U, Th and K in surface rocks were analyzed. The South Indian Craton according to Drury et al., can be divided into various blocks, separated by late Proterozoic shear belts. The northern block comprises Eastern and Western Dharwar Cratons of Rogers (1986), Naqvi and Rogers (1987) and a part of the South Indian granulite terrain up to a shear system occupying the Palghat-Cauvery low lands. The geothermal data analysis clearly demonstrates that the present thermal characteristics of the above two Archaean terrains of the Indian and Australian Shields are quite similar. Their crustal thermal structures are likely to be similar also.

  15. Coupling between entropy and unsteady heat release in a thermoacoustic system with a mean flow

    Science.gov (United States)

    Li, Lei; Zhao, Dan

    2016-11-01

    In this work, the coupling between entropy and unsteady heat release in a one dimensional duct in the presence of a mean flow is considered. As acoustic disturbances impinge on a compact heat source enclosed in the duct, entropy disturbances are generated. The transfer function between the generated entropy waves and oncoming flow velocity fluctuations is deduced by conducting order analysis of the linearized governing equations. The effects of the mean flow are emphasized for different forms of unsteady heat release model. It is shown that there is a strong coupling between entropy, heat release, mean flow and acoustic impedance at the heat source. To validate our theoretical analysis, numerical investigation is conducted by using a low order model. Comparing the theoretical and the low order model's results reveals that a good agreement is observed. It is found that when the mean flow Mach number is not negligible, the term of O(M1) in the identified entropy transfer function is as important as that of O(M0). Neglecting the term of O(M1) may lead to wrong prediction of the entropy waves produced in the system.

  16. Turbulent Heat Transfer Characteristics in the Shear Layer of a Separated Flow

    Science.gov (United States)

    Jovic, S.; Kutler, Paul F. (Technical Monitor)

    1994-01-01

    Experiments were performed to study the evolution of the heat transfer structure in a separated free shear layer region of an incompressible separated turbulent boundary layer flow behind a backward-facing step. While there is an abundance of velocity field measurements of separated flows, heat transfer measurements are rather scarce, thus limiting assessment of the heat transfer physics and its accurate modeling. The purpose of the paper is twofold: to improve an understanding of effects of flow separation on heat transfer characteristics, and to provide data for turbulence modeling and computation. The boundary layer upstream of the step was turbulent and fully developed. A constant temperature surface boundary condition was imposed upstream and downstream of the step for the heat transfer study. An internal mixing-layer like flow forms and grows from the step lip within the original boundary layer. The turbulent structure of the flow evolving downstream, however, does not switch immediately to that of a mixing layer over the entire shear layer thickness. Measurements of mean and fluctuating velocity and temperature fields indicate that the internal layer spreads gradually in the transverse direction while the outer part of the original boundary layer is effectively unperturbed. The results in this paper have not been previously reported.

  17. Flow patterns and heat convection in a rectangular water bolus for use in superficial hyperthermia.

    Science.gov (United States)

    Birkelund, Yngve; Jacobsen, Svein; Arunachalam, Kavitha; Maccarini, Paolo; Stauffer, Paul R

    2009-07-07

    This paper investigates both numerically and experimentally the spatio-temporal effects of water flow in a custom-made water bolus used for superficial hyperthermia generated by a 915-MHz, 4 x 3 microwave applicator array. Similar hyperthermia models referenced in the literature use a constant water temperature and uniform heat flux to describe conduction and convection energy exchange within the heating apparatus available to cool the tissue surface. The results presented in this paper show that the spatially varying flow pattern and rate are vital factors for the overall heat control applicability of the 5 mm thick bolus under study. Regions with low flow rates and low heat convection clearly put restrictions on the maximum microwave energy possible within the limits of skin temperature rise under the bolus. Our analysis is illustrated by experimental flow front studies using a contrast liquid set-up monitored by high definition video and complemented by numerical analysis of liquid flow and heat exchange within the rectangular water bolus loaded by malignant tissue. Important factors for the improvement of future bolus designs are also discussed in terms of diameter and configuration of the water input and output tubing network.

  18. Simulation of Fluid Flow and Heat Transfer in Porous Medium Using Lattice Boltzmann Method

    Science.gov (United States)

    Wijaya, Imam; Purqon, Acep

    2017-07-01

    Fluid flow and heat transfer in porous medium are an interesting phenomena to study. One kind example of porous medium is geothermal reservoir. By understanding the fluid flow and heat transfer in porous medium, it help us to understand the phenomena in geothermal reservoir, such as thermal change because of injection process. Thermal change in the reservoir is the most important physical property to known since it has correlation with performance of the reservoir, such as the electrical energy produced by reservoir. In this simulation, we investigate the fluid flow and heat transfer in geothermal reservoir as a simple flow in porous medium canal using Lattice Boltzmann Method. In this simulation, we worked on 2 dimension with nine vectors velocity (D2Q9). To understand the fluid flow and heat transfer in reservoir, we varied the fluid temperature that inject into the reservoir and set the heat source constant at 410°C. The first variation we set the fluid temperature 45°C, second 102.5°C, and the last 307.5°C. Furthermore, we also set the parameter of reservoir such as porosity, density, and injected fluid velocity are constant. Our results show that for the first temperature variation distribution between experiment and simulation is 92.86% match. From second variation shows that there is one pick of thermal distribution and one of turbulence zone, and from the last variation show that there are two pick of thermal distribution and two of turbulence zone.

  19. Stagnation-Point Flow toward a Vertical, Nonlinearly Stretching Sheet with Prescribed Surface Heat Flux

    Directory of Open Access Journals (Sweden)

    Sin Wei Wong

    2013-01-01

    Full Text Available An analysis is carried out to study the steady two-dimensional stagnation-point flow of an incompressible viscous fluid towards a stretching vertical sheet. It is assumed that the sheet is stretched nonlinearly, with prescribed surface heat flux. This problem is governed by three parameters: buoyancy, velocity exponent, and velocity ratio. Both assisting and opposing buoyant flows are considered. The governing partial differential equations are transformed into a system of ordinary differential equations and solved numerically by finite difference Keller-box method. The flow and heat transfer characteristics for different values of the governing parameters are analyzed and discussed. Dual solutions are found in the opposing buoyant flows, while the solution is unique for the assisting buoyant flows.

  20. Flow resistance characteristics of water in narrow annulus during heat exchange

    Institute of Scientific and Technical Information of China (English)

    SUN Li-cheng; YAN Chang-qi; SUN Zhong-ning; ZHANG Qing-hua

    2003-01-01

    Considering the special resistance characteristics of fluids flowing through ducts with small gaps, experiments are performed to investigate the resistance characteristics of single-phase water, which is forced to flow through vertical annuli. The gap sizes are 0.9, 1.4 and 2.4mm, respectively. The experiments are conducted under condition of 1atm. The water in the annuli is heated by high temperature water reversely flowing through the inner tube and the outer annulus. The results show that the flow pattern begin to change from laminar to turbulent before Reynolds number approaches 2000, the flow resistance in annulus has little relations with the temperature difference and ways of being heated, but mainly depends on the ratio of mass flux to the width of annulus.

  1. Boundary layer flow and heat transfer in a viscous fluid over a stretching sheet with viscous dissipation, internal heat generation and prescribed heat flux

    Science.gov (United States)

    Jamaludin, Anuar; Nazar, Roslinda; Shafie, Sharidan

    2017-08-01

    This study presents the numerical solutions of boundary layer flow and heat transfer over a stretching sheet with viscous dissipation and internal heat generation. Thermal boundary condition on the surface, namely prescribed heat flux (PHF) is used. The governing nonlinear partial differential equations are transformed into nonlinear ordinary differential equations by applying the similarity transformations before reduced to the system of first order ordinary differential equations. Then the system of first order ordinary differential equations is solved numerically using an implicit finite difference scheme, known as the Keller-box method. The numerical solutions are generated using MATLAB. Temperature profiles and the temperature gradient for some values of the Prandtl number, Eckert number and heat/source sink parameter are presented in figures and discussed in details.

  2. Heat flow along the Costa Rica Seismogenesis Project drilling transect: Implications for hydrothermal and seismic processes

    Science.gov (United States)

    Hass, Bridget; Harris, Robert N.

    2016-06-01

    Heat flow analysis of the Costa Rica convergent margin is carried out for seven sites drilled during Integrated Ocean Drilling Program (IODP) Expeditions 334 and 344 as part of the Costa Rica Seismogenesis Project (CRISP). These expeditions are designed to better understand erosional subduction zones. Heat flow measurements were made to improve estimates of the thermal structure of this erosive margin and are located on the incoming plate, toe, lower, middle, and upper slopes of the margin. Heat flow values corrected for the effects of seafloor bathymetry and sedimentation are on average 15% higher than uncorrected values and range from approximately 158-200 mW/m2 on the incoming plate to values of approximately 50 mW/m2 on the middle and upper slopes of the margin. These values are consistent with previous estimates of heat flow showing a landward decrease in heat flow consistent with subduction of the Cocos plate. Preferred thermal models of the shallow subduction zone successfully predicting observed values of heat flow incorporate fluid flow within the upper oceanic aquifer have an uppermost permeability of 10-9.5 m2 and a plate boundary effective coefficient of friction of 0.06. These models suggest that temperatures on the subduction thrust reach 100°C at distances between 30 and 35 km landward of the deformation front. The updip limit of seismicity, as defined by aftershocks events of ML 1-4 recorded following the Mw 6.9 Quepos earthquake, occurs at 25 km landward of the deformation front at temperatures cooler than the 100-150°C typically predicted.

  3. Sensing turbulent flow and heat transport in a cave conduit

    Science.gov (United States)

    Kurtzman, D.; Lucia, F. J.; Jennings, J. W.; Wilson, J. L.; Tyler, S. W.; Jorgensen, A. M.; Dwivedi, R.; Boston, P.; Burger, P.

    2008-12-01

    Cave systems provide an extreme example of complex subsurface porous media, dominated by flow through an interconnected network of conduits. Whether water or air-filled, these flow systems have been largely observed subjectively, with only a few simple quantitative measurements of flow and pressure. In the spring of 2008 a joint campaign of New Mexico Tech and the University of Nevada Reno entered the 210m deep, ~8m "diameter," keyhole shaped, subhorizontal, Left Hand Tunnel, a large air-filled conduit in Carlsbad Caverns, New Mexico, with the intent to observe fluid flow with modern thermally-based instruments. The conduit experiences countercurrent, thermally stratified flow, with mean velocities in each layer less than 0.1m/s. It is part of a geothermally forced, large-scale convection cell. Two instruments were deployed. A distributed temperature sensing (DTS) fiber optic cable was stretched over 1km of the tunnel, and partially suspended by balloons to the roof, to sense spatial and low-frequency (0.01Hz) temporal variations of temperature with a resolution approaching 0.05 degree C. The mean temperature difference between layers was on the order of 0.5 degree and the caveward (subhorizontal) temperature gradient was 1 degree/400m. Influences of connecting subvertical shafts, wet areas of the cave, human activity, and diurnal fluctuations were observed. The second instrument, a 7m tall tower with an array of eight 300Hz thermocouple temperature sensors, with a sensitivity approaching 0.005 degree, was deployed 200m into the tunnel and used to detect high- frequency temperature fluctuations associated with turbulence and the stratified flow. Turbulence structure of each layer was similar. Temperature fluctuation (and turbulence intensity?) was significantly greater near the boundary between layers and its steep vertical gradient of mean temperature. Results from this 3-day campaign, as limited as they are, suggest that there is a wealth of information and

  4. Visualization of the boiling phenomena and counter-current flow limit of annular heat pipe

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Guk; Kim, Kyung Mo; Jeong, Yeong Shin; Bang, In Cheol [UNIST, Ulsan (Korea, Republic of)

    2015-10-15

    The thermal resistance of conventional heat pipes increases over the capillary limit because of the insufficient supplement of the working fluid. Due to the shortage of the liquid supplement, thermosyphon is widely used for vertically oriented heat transport and high heat load conditions. Thermosyphons are two-phase heat transfer devices that have the highly efficient heat transport from evaporation to condensation section that makes an upward driving force for vapor. In the condenser section, the vapor condenses and releases the latent heat. Due to the gravitation force acting on the liquid in the tube, working fluid back to the evaporator section, normally this process operate at the vertical and inclination position. The use of two-phase closed thermosyphon (TPCT) for the cooling devices has the limitation due to the phase change of the working fluid assisted by gravity force. Due to the complex phenomenon of two-phase flow, it is required to understand what happened in TPCT. The visualization of the thermosyphon and heat pipe is investigated for the decrease of thermal resistance and enhancement of operation limit. Weibel et al. investigated capillary-fed boiling of water with porous sintered powder wick structure using high speed camera. At the high heat flux condition, dry-out phenomenon and a thin liquid film are observed at the porous wick structure. Wong and Kao investigated the evaporation and boiling process of mesh wicked heat pipe using optical camera. At the high heat flux condition, the water filing became thin and partial dry-out was observed in the evaporator section. Our group suggested the concept of a hybrid heat pipe with control rod as Passive IN-core Cooling System (PINCs) for decay heat removal for advanced nuclear power plant. The hybrid heat pipe is the combination of the heat pipe and control rod. It is necessary for PINCs to contain a neutron absorber (B{sub 4}C) to have the ability of reactivity control. It has annular vapor space and

  5. Heat flow method to Lichnerowicz type equation on closed manifolds

    OpenAIRE

    Li MA; Sun, Yuhua

    2010-01-01

    In this paper, we establish existence results for positive solutions to the Lichnerowicz equation of the following type in closed manifolds -\\Delta u=A(x)u^{-p}-B(x)u^{q},\\quad in\\quad M, where $p>1, q>0$, and $A(x)>0$, $B(x)\\geq0$ are given smooth functions. Our analysis is based on the global existence of positive solutions to the following heat equation {ll} u_t-\\Delta u=A(x)u^{-p}-B(x)u^{q},\\quad in\\quad M\\times\\mathbb{R}^{+}, u(x,0)=u_0,\\quad in\\quad M with the positive smooth initial da...

  6. Effects of Surface Wettability and Roughness on the Heat Transfer Performance of Fluid Flowing through Microchannels

    Directory of Open Access Journals (Sweden)

    Jing Cui

    2015-06-01

    Full Text Available The surface characteristics, such as wettability and roughness, play an important role in heat transfer performance in the field of microfluidic flow. In this paper, the process of a hot liquid flowing through a microchannel with cold walls, which possesses different surface wettabilities and microstructures, is simulated by a transient double-distribution function (DDF two-phase thermal lattice Boltzmann BGK (LBGK model. The Shan-Chen multiphase LBGK model is used to describe the flow field and the independent distribution function is introduced to solve the temperature field. The simulation results show that the roughness of the channel wall improves the heat transfer, no matter what the surface wettability is. These simulations reveal that the heat exchange characteristics are directly related to the flow behavior. For the smooth-superhydrophobic-surface flow, a gas film forms that acts as an insulating layer since the thermal conductivity of the gas is relatively small in comparison to that of a liquid. In case of the rough-superhydrophobic-surface flow, the vortex motion of the gas within the grooves significantly enhances the heat exchange between the fluid and wall.

  7. Numerical investigation of flow and heat transfer performances of horizontal spiral-coil pipes

    Institute of Scientific and Technical Information of China (English)

    季家东; 葛培琪; 毕文波

    2016-01-01

    The flow and heat transfer performances of horizontal spiral-coil pipes of circular and elliptical cross-sections are studied. The numerical results are compared with the experimental data, to verify the numerical method. The effects of the inlet water mass flow rate, the structural parameters, the helical pitch and the radius ratio on the heat transfer performances are investigated. Perfor- mances of the secondary fluid flow with different radius ratios are also investigated. Numerical results demonstrate that the heat transfer coefficient and the Nusselt number increase with the increase of the water mass flow rate or the helical pitch. The maximum heat transfer coefficient and the maximum Nusselt number are obtained when the radius ratio isequal to 1.00. In addition, the fluid particle moves spirally along the pipe and the velocity changes periodically. The particle flow intensity and the spiral movement frequency decrease significantly with the increase of the radius ratio. Besides, the secondary flow profile in the horizontal spiral-coil pipe contains two oppositely rotating eddies, and the eddy intensity decreases significantly along the pipe owing to the change of curvature. The decreasing tendency of the eddy intensity along the pipe increases with the increase of the radius ratio.

  8. EFFECT OF HORIZONTALLY INHOMOGENEOUS HEATING ON FLOW AND MAGNETIC FIELD IN THE CHROMOSPHERE OF THE SUN

    Energy Technology Data Exchange (ETDEWEB)

    Song, P.; Vasyliūnas, V. M., E-mail: paul_song@uml.edu [Space Science Laboratory and Department of Physics, University of Massachusetts Lowell, Lowell, MA 01854 (United States)

    2014-12-01

    The solar chromosphere is heated by damped Alfvén waves propagating upward from the photosphere at a rate that depends on magnetic field strength, producing enhanced heating at low altitudes in the extended weak-field regions (where the additional heating accounts for the radiative losses) between the boundaries of the chromospheric network as well as enhanced heating per particle at higher altitudes in strong magnetic field regions of the network. The resulting inhomogeneous radiation and temperature distribution produces bulk flows, which in turn affect the configuration of the magnetic field. The basic flow pattern is circulation on the spatial scale of a supergranule, with upward flow in the strong-field region; this is a mirror image in the upper chromosphere of photospheric/subphotospheric convection widely associated with the formation of the strong network field. There are significant differences between the neutral and the ionized components of the weakly ionized medium: neutral flow streamlines can form closed cells, whereas plasma is largely constrained to flow along the magnetic field. Stresses associated with this differential flow may explain why the canopy/funnel structures of the network magnetic field have a greater horizontal extent and are relatively more homogeneous at high altitudes than is expected from simple current-free models.

  9. Wide Range Flow and Heat Flux Sensors for In-Flight Flow Characterization Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The tracking of critical flow features (CFFs) such as stagnation point, flow separation, shock, and transition in flight provides insight into actual aircraft...

  10. Determination of thermal characteristics of combustion products of fire-tube heat generator with flow turbulator

    Directory of Open Access Journals (Sweden)

    Lukjanov Alexander V.

    2014-12-01

    Full Text Available Boiler construction is one of the major industries of any state. The aim is to determine the effect of the turbulator on the intensity of heat transfer in the convective part of the fire-tube heat generator of domestic production. The improvement of convective heating surfaces is one of the ways to increase the energy efficiency of the fire-tube heat generator. Since model of the process of heat transfer of gas flow in the convective tubes is multifactorial and does not have clear analytical solution at present, the study of process above is carried out using the experimental method. The results of applying the flow turbulator as a broken tape in the fire-tube heat generator of KV-GM type are presented. On their basis it can be concluded about increasing of heat transfer in convective part of the unit. The use of efficient, reliable, easy to manufacture, relatively inexpensive turbulator in domestic fire-tube heat generators will allow to increase their energy conversion efficiency and reduce fuel consumption, which will have a positive economic effect.

  11. Influence of an insulating megaregolith on heat flow and crustal temperature structure of Mercury

    Science.gov (United States)

    Egea-González, Isabel; Ruiz, Javier

    2014-04-01

    Mercury is covered by a megaregolith layer, which constitutes a poor thermally conducting layer that must have an influence on the thermal state and evolution of the planet, although most thermal modeling or heat flow studies have overlooked it. In this work we have calculated surface heat flows and subsurface temperatures from the depth of thrust faults associated with several prominent lobate scarps on Mercury, valid for the time of the formation of these scarps, by solving the heat equation and taking into account the insulating effects of a megaregolith layer. We conclude that megaregolith insulation could have been an important factor limiting heat loss and therefore interior cooling and contraction of Mercury. As mercurian megaregolith properties are not very well known, we also analyze the influence of these properties on the results, and discuss the consequences of imposing the condition that the total radioactive heat production must be lower than the total surface heat loss (this is, the Urey ratio, Ur, must be lower than 1) in a cooling and thermally contracting planet such as Mercury at the time of scarp emplacement. Our results show that satisfying the condition of Ur < 1 implies that the average abundances of heat-producing elements silicate layer is 0.4 times or less the average surface value, placing an upper bound on the bulk content of heat producing elements in Mercury’s interior.

  12. Influence of heat and mass flux conditions in hydromagnetic flow of Jeffrey nanofluid

    Energy Technology Data Exchange (ETDEWEB)

    Abbasi, F. M. [Department of Mathematics, Comsats Institute of Information Technology, Islamabad 44000 (Pakistan); Shehzad, S. A., E-mail: ali-qau70@yahoo.com [Department of Mathematics, Comsats Institute of Information Technology, Sahiwal 57000 (Pakistan); Hayat, T. [Department of Mathematics, Quaid-I-Azam University 45320, Islamabad 44000 (Pakistan); Nonlinear Analysis and Applied Mathematics (NAAM) Research Group, Department of Mathematics, Faculty of Science, King Abdulaziz University, Jeddah (Saudi Arabia); Alsaedi, A.; Obid, Mustafa A. [Nonlinear Analysis and Applied Mathematics (NAAM) Research Group, Department of Mathematics, Faculty of Science, King Abdulaziz University, Jeddah (Saudi Arabia)

    2015-03-15

    This article explores the hydromagnetic steady flow of Jeffrey fluid in the presence of thermal radiation. The chosen nanofluid model takes into account the Brownian motion and thermophoresis effects. Flow and heat transfer characteristics are determined by a stretching surface with flux conditions. The nonlinear boundary layer flow through partial differential systems is converted into the ordinary differential systems. The resulting reduced systems are computed for the convergent solutions of velocity, temperature and nanoparticle concentration. Graphs of dimensionless temperature and nanoparticle concentration profiles are presented for different values of emerging parameters. Skin-friction coefficient are computed and analyzed in both hydrodynamic and hydromagnetic flow situations.

  13. Influence of heat and mass flux conditions in hydromagnetic flow of Jeffrey nanofluid

    Directory of Open Access Journals (Sweden)

    F. M. Abbasi

    2015-03-01

    Full Text Available This article explores the hydromagnetic steady flow of Jeffrey fluid in the presence of thermal radiation. The chosen nanofluid model takes into account the Brownian motion and thermophoresis effects. Flow and heat transfer characteristics are determined by a stretching surface with flux conditions. The nonlinear boundary layer flow through partial differential systems is converted into the ordinary differential systems. The resulting reduced systems are computed for the convergent solutions of velocity, temperature and nanoparticle concentration. Graphs of dimensionless temperature and nanoparticle concentration profiles are presented for different values of emerging parameters. Skin-friction coefficient are computed and analyzed in both hydrodynamic and hydromagnetic flow situations.

  14. Heat transfer measurements in fully turbulent flows: basic investigations with an advanced thin foil triple sensor

    Science.gov (United States)

    Mocikat, H.; Herwig, H.

    2008-07-01

    In a former article in this journal a double layer hot film with two 10 μm nickel foils, separated by a 25 μm polyimide foil was introduced as a multi-purpose sensor. Each foil can be operated as a (calibrated) temperature sensor in its passive mode by imposing an electric current small enough to avoid heating by dissipation of electrical energy. Alternatively, however, each foil can also serve as a heater in an active mode with electric currents high enough to cause Joule heating. This double foil sensor can be used as a conventional heat flux sensor in its passive mode when mounted on an externally heated surface. In fully turbulent flows it alternatively can be operated in an active mode on a cold, i.e. not externally heated surface. Then, by heating the upper foil, a local heat transfer is initiated from which the local heat transfer coefficient h can be determined, once the lower foil is heated to the same temperature as the upper one, thus acting as a counter-heater. For further investigations with respect to the underlying sensor concept a triple sensor has been built which consists of three double layer film sensors very close to each other. Various aspects of heat transfer measurements in active modes can be addressed by this sensor.

  15. Stagnation point flow and heat transfer on a thin porous sheet: Applications to flow dynamics of the circulatory system

    Science.gov (United States)

    Misra, J. C.; Sinha, A.; Mallick, B.

    2017-03-01

    The paper is concerned with the modeling and analysis of stagnation point flow and heat transfer on a thin porous sheet under the action of an induced magnetic field. The fluid is considered to be incompressible viscous and electrically conducting. The study is motivated towards exploring some interesting phenomena in the micro-circulatory system. Heat transfer is considered to be governed by the heat equation. In order to take care of the induced magnetism that affects the flow process, the flow equations are coupled with magnetic field variables. The analysis has been performed under the purview of the boundary layer theory, together with the use of similarity transformation. The transformed equations are solved by developing an appropriate numerical method. Numerical results have been computed for a typical situation of the fluid in motion. The results are displayed graphically/in tabular form, which depict the distribution of velocity and temperature under the action of the induced magnetic field and permeability of the porous sheet. The study shows that the flow of the fluid reduces, as the strength of the induced magnetic field increases. However, the reduction in velocity is accompanied by an enhancement of the temperature field.

  16. Buoyancy driven flow in a hot water tank due to standby heat loss

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2012-01-01

    show that the CFD model predicts satisfactorily water temperatures at different levels of the tank during cooling by standby heat loss. It is elucidated how the downward buoyancy driven flow along the tank wall is established by the heat loss from the tank sides and how the natural convection flow......Results of experimental and numerical investigations of thermal behavior in a vertical cylindrical hot water tank due to standby heat loss of the tank are presented. The effect of standby heat loss on temperature distribution in the tank is investigated experimentally on a slim 150l tank...... parts of the tank is measured by experiments and used as input to the CFD model. Water temperatures at different levels of the tank are measured and compared to CFD calculated temperatures. The investigations focus on validation of the CFD model and on understanding of the CFD calculations.The results...

  17. Simple computer program to model 3-dimensional underground heat flow with realistic boundary conditions

    Science.gov (United States)

    Metz, P. D.

    A FORTRAN computer program called GROCS (GRound Coupled Systems) has been developed to study 3-dimensional underground heat flow. Features include the use of up to 30 finite elements or blocks of Earth which interact via finite difference heat flow equations and a subprogram which sets realistic time and depth dependent boundary conditions. No explicit consideration of mositure movement or freezing is given. GROCS has been used to model the thermal behavior of buried solar heat storage tanks (with and without insulation) and serpentine pipe fields for solar heat pump space conditioning systems. The program is available independently or in a form compatible with specially written TRNSYS component TYPE subroutines. The approach taken in the design of GROCS, the mathematics contained and the program architecture, are described. Then, the operation of the stand-alone version is explained. Finally, the validity of GROCS is discussed.

  18. A Model of Solar Radiation and Joule Heating in Flow of Third Grade Nanofluid

    Science.gov (United States)

    Hussain, Tariq; Hayat, Tasawar; Shehzad, Sabir Ali; Alsaedi, Ahmed; Chen, Bin

    2015-03-01

    The flow problem resulting from the stretching of a surface with convective conditions in a magnetohydrodynamic nanofluid with solar radiation is examined. Both heat and nanoparticle mass transfer convective conditions are employed. An incompressible third grade fluid which exhibits shear thinning and shear thickening characteristics is used as a base fluid. Concept of convective nanoparticle mass condition is introduced. Effects of Brownian motion and thermophoresis on magnetohydrodynamic flow of nanofluid are accounted in the presence of thermal radiation. Energy equation incorporates the features of Joule heating. The impact of physical parameters on the temperature and nanoparticle concentration has been pointed out. Numerical values of skin-friction coefficient are presented and analysed. It is hoped that this present investigation serves as a stimulus for the next generation of solar film collectors, heat exchangers technology, material processing, geothermal energy storage, and all those processes which are highly affected by the heat enhancement concept.

  19. The technology of heat transfer enhancement in channels by means of flow pulsations

    Directory of Open Access Journals (Sweden)

    Tsynaeva Anna

    2016-01-01

    Full Text Available The rate and efficiency of curing of concrete can boost when used intense heat. The work is dedicated to the development and research of technologies of intensification of heat transfer in channels by pulsations. The study was conducted by means of numerical methods based on mass and momentum conservation equations (Navier-Stokes with software Code Saturne. Verification of implemented methods and software was performed. The research of heat transfer enhancement for semicircle-shaped channel exposed to low-frequency pulsations was performed. The pulsation frequency of the flow during the study was in a range of 0…10 Hz. A significant (up to 4 times increase of turbulent kinetic energy with implementing pulsations was detected. Flow pulsations with frequency of 10 Hz results in 1.21 times increase of heat transfer coefficient.

  20. Momentum and Heat Transfer in MHD Axisymmetric Stagnation-Point Flow over a Shrinking Sheet

    Directory of Open Access Journals (Sweden)

    T. R. Mahapatra

    2013-01-01

    Full Text Available In this paper we present a mathematical analysis for the magneto hydrodynamic (MHD axi-symmetric stagnation-point flow and heat transfer over a shrinking sheet which shrinks axi-symmetrically in its own plane. The governing partial differential equations along with the boundary conditions are first cast into a dimensionless form and then these equations are solved numerically by shooting technique. Thermal conductivity is assumed to vary linearly with the temperature. Temperature profiles are obtained for two different types of heating process namely (i the sheet with prescribed surface temperature (PST and (ii the sheet with prescribed surface heat flux (PHF. The effects of various physical parameters on the flow and heat transfer characteristics are presented graphically and discussed.

  1. Radiation Effect on Mhd Heat and Mass Transfer Flow over a Shrinking Sheet with Mass Suction

    Directory of Open Access Journals (Sweden)

    patkar ramesh

    2014-01-01

    Full Text Available A numerical analysis has been carried out to study the effects radiation and heat source/sink on the steady two dimensional magnetohydrodynamic (MHD boundary layer flow of heat and mass transfer past a shrinking sheet with wall mass suction. In the dynamic system, a uniform magnetic field acts normal to the plane of flow. The governing partial differential equations are transformed into self-similar equations are solved by employing finite difference using the quasilinearization technique. From the analysis it is found that the velocity inside the boundary layer increases with increase of wall mass suction and magnetic field and accordingly the thickness of the momentum boundary layer decreases. The temperature decreases with Hartmann number, Prandtl number, and heat sink parameter and the temperature increases with heat source parameter, radiation parameter. The concentration decreases with an increase of Hartmann number, mass suction parameter, Schmidt number, chemical reaction parameter.

  2. Heat stress redistributes blood flow in arteries of the brain during dynamic exercise.

    Science.gov (United States)

    Sato, Kohei; Oue, Anna; Yoneya, Marina; Sadamoto, Tomoko; Ogoh, Shigehiko

    2016-04-01

    We hypothesized that heat stress would decrease anterior and posterior cerebral blood flow (CBF) during exercise, and the reduction in anterior CBF would be partly associated with large increase in extracranial blood flow (BF). Nine subjects performed 40 min of semirecumbent cycling at 60% of the peak oxygen uptake in hot (35°C; Heat) and thermoneutral environments (25°C; Control). We evaluated BF and conductance (COND) in the external carotid artery (ECA), internal carotid artery (ICA), and vertebral artery (VA) using ultrasonography. During the Heat condition, ICA and VA BF were significantly increased 10 min after the start of exercise (P brain arteries to exercise, which resulted in an alteration in the distribution of cardiac output. Moreover, a hyperthermia-induced increase in extracranial BF might compromise anterior CBF during exercise with heat stress.

  3. Experimental And Analytical Study Of Heat Transfer And Fluid Flow Through Aluminum Foams

    Science.gov (United States)

    Mancin, Simone; Zilio, Claudio; Rossetto, Luisa; Cavallini, Alberto

    2010-05-01

    This paper aims at investigating the air heat transfer and fluid flow through eight Aluminum open cell foam samples with different number of pores per linear inch (PPI ranging between 5 and 40), almost constant porosity (around 0.92-0.93) and different foam core heights (20 and 40 mm). The experimental heat transfer coefficient and pressure drop measurements have been collected in a test rig built at Dipartimento di Fisica Tecnica of the University of Padova. Three different heat fluxes have been imposed: 25.0, 32.5 and 40.0 kW m-2 and the air mass flow rate has been varied between 0.005 and 0.025 kg s-1, with air approach velocity between 2 and 5 m s-1. The effect of the foam height on the heat transfer has been experimentally analysed. Finally, the pressure drop measurements have been compared against an analytical model suggested in the open literature.

  4. Role of bubble growth dynamics on microscale heat transfer events in microchannel flow boiling process

    Science.gov (United States)

    Bigham, Sajjad; Moghaddam, Saeed

    2015-12-01

    For nearly two decades, the microchannel flow boiling heat transfer process has been the subject of numerous studies. A plethora of experimental studies have been conducted to decipher the underlying physics of the process, and different hypotheses have been presented to describe its microscopic details. Despite these efforts, the underlying assumptions of the existing hypothesis have remained largely unexamined. Here, using data at the microscopic level provided by a unique measurement approach, we deconstruct the boiling heat transfer process into a set of basic mechanisms and explain their role in the overall surface heat transfer. We then show how this knowledge allows to relate the bubble growth and flow dynamics to the surface heat flux.

  5. MHD mixed convection flow through a diverging channel with heated circular obstacle

    Science.gov (United States)

    Alam, Md. S.; Shaha, J.; Khan, M. A. H.; Nasrin, R.

    2016-07-01

    A numerical study of steady MHD mixed convection heat transfer and fluid flow through a diverging channel with heated circular obstacle is carried out in this paper. The circular obstacle placed at the centre of the channel is hot with temperature Th. The top and bottom walls are non-adiabatic. The basic nonlinear governing partial differential equations are transformed into dimensionless ordinary differential equations using similarity transformations. These equations have been solved numerically for different values of the governing parameters, namely Reynolds number (Re), Hartmann number (Ha), Richardson number (Ri) and Prandtl number (Pr) using finite element method. The streamlines, isotherms, average Nusselt number and average temperature of the fluid for various relevant dimensionless parameters are displayed graphically. The study revealed that the flow and thermal fields in the diverging channel depend significantly on the heated body. In addition, it is observed that the magnetic field acts to increase the rate of heat transfer within the channel.

  6. Modeling Heat Flow In a Calorimeter Equipped With a Textured Solar Collector

    Science.gov (United States)

    Jaworske, Donald A.; Allen, Bradley J.

    2001-01-01

    Heat engines are being considered for generating electric power for minisatellite applications, particularly for those missions in high radiation threat orbits. To achieve this objective, solar energy must be collected and transported to the hot side of the heat engine. A solar collector is needed having the combined properties of high solar absorptance, low infrared emittance, and high thermal conductivity. To test candidate solar collector concepts, a simple calorimeter was designed, manufactured, and installed in a bench top vacuum chamber to measure heat flow. In addition, a finite element analysis model of the collector/calorimeter combination was made to model this heat flow. The model was tuned based on observations from the as-manufactured collector/calorimeter combination. In addition, the model was exercised to examine other collector concepts, properties, and scale up issues.

  7. Flow structure and heat exchange analysis in internal cooling channel of gas turbine blade

    Science.gov (United States)

    Szwaba, Ryszard; Kaczynski, Piotr; Doerffer, Piotr; Telega, Janusz

    2016-08-01

    This paper presents the study of the flow structure and heat transfer, and also their correlations on the four walls of a radial cooling passage model of a gas turbine blade. The investigations focus on heat transfer and aerodynamic measurements in the channel, which is an accurate representation of the configuration used in aeroengines. Correlations for the heat transfer coefficient and the pressure drop used in the design of radial cooling passages are often developed from simplified models. It is important to note that real engine passages do not have perfect rectangular cross sections, but include corner fillet, ribs with fillet radii and special orientation. Therefore, this work provides detailed fluid flow and heat transfer data for a model of radial cooling geometry which possesses very realistic features.

  8. Heat-flow equation motivated by the ideal-gas shock wave.

    Science.gov (United States)

    Holian, Brad Lee; Mareschal, Michel

    2010-08-01

    We present an equation for the heat-flux vector that goes beyond Fourier's Law of heat conduction, in order to model shockwave propagation in gases. Our approach is motivated by the observation of a disequilibrium among the three components of temperature, namely, the difference between the temperature component in the direction of a planar shock wave, versus those in the transverse directions. This difference is most prominent near the shock front. We test our heat-flow equation for the case of strong shock waves in the ideal gas, which has been studied in the past and compared to Navier-Stokes solutions. The new heat-flow treatment improves the agreement with nonequilibrium molecular-dynamics simulations of hard spheres under strong shockwave conditions.

  9. Heat Transfer Augmentation in Developing Flow Through a Ribbed Square Duct

    Institute of Scientific and Technical Information of China (English)

    Khan R K; Ali M.A.T; Akhanda M.A.R

    2006-01-01

    An experimental study is conducted to investigate the heat transfer augmentation in developing turbulent flow through a ribbed square duct. The duct is made of 16mm thick bakelite sheet. The bottom surface of the ribbed wall having rib pitch to height ratio of 10 is heated by passing a c current to the heater placed under it. The uniform heating is controlled using a digital temperature controller and a variac. The results of ribbed duct are compared with the results of a smooth duct under the same experimental conditions. It is observed that the heat transfer augmentation in ribbed duct is better than that of the smooth duct. At Re=5.0 × 104 , the mean temperature of air flowing through the ribbed duct increases by 2.45 percent over the smooth duct, whereas in the ribbed duct Nusselt number increases by 15.14 percent than that of the smooth duct with a 6 percent increase in pressure drop.

  10. Improvement of Heating Method for Measuring the Wetness of Flowing Wet Steam

    Institute of Scientific and Technical Information of China (English)

    1998-01-01

    In this paper,an improvement of heating method for measuring wetness of the flowing wet steam is developed,the basic principle of the heating method is presented and the mathematical model has been built for analyzing the thermodynamics problems during the process of heating,Moreover,an instrument for measuring wetness of wet steam flow was designed and made out.This instument has been used for measuring wetness of the wet steam flow at the outlet of the nozzle rig in Thermal Turbine Laboratory,Xi'an Jiaotong University,By analyzing the relative error of the result,it was found that this instrument has fairly high accuracy,it can be used as the prototype of practical instrument and has an important applicable value in engineering.

  11. Constraints on Pacific midplate swells from global depth-age and heat flow-age models

    Science.gov (United States)

    Stein, Carol A.; Stein, Seth

    Oceanic midplate swells are identified by shallow seafloor depths. In turn, models of the processes giving rise to these regions rely on assessments of how their depths, surface heat flow, and flexural properties differ from those for lithosphere which is presumed not to have been affected by these processes. Such comparisons have been inhibited because reference thermal models, which are assumed to describe unperturbed lithosphere, predict deeper depths and lower heat flow than typically observed for lithosphere older than 70 Ma. As a result, both depth and heat flow anomalies can be overestimated. To address this difficulty, we have derived model GDH1 (Global Depth and Heat flow) by joint fitting of heat flow and bathymetry. GDH1, which has a hotter and thinner lithosphere than previous models, fits the depth and heat flow data significantly better, including the data from older lithosphere previously treated as anomalous. It also provides an improved fit to depth-to-basement data for ocean drilling sites, and to geoid offsets across fracture zones. The improved fit occurs for depth-age data from both the DBDB-5 digital bathymetry, and from regional medians from ship tracks, which yield comparable depth-age curves. We use GDH1 to study three classes of midplate swells: the Hawaiian and other hot spot swells, the Darwin Rise area of widespread Cretaceous volcanism, and the Superswell, considered a present analogue to the Darwin Rise. Heat flow on the Hawaiian swell, though anomalously high with respect to previous reference models, is at most slightly high relative to GDH1. The situation is similar for the Bermuda, Cape Verde, and Crozet hot spots. The absence of a significant heat flow anomaly favors a primarily dynamic, rather than thermal, origin for these swells. Similarly, the present depths and heat flow for the Darwin Rise are consistent with GDH1, although they were anomalous with respect to previous reference models. The depth and heat flow data thus

  12. Use of two-phase flow heat transfer method in spacecraft thermal system

    Science.gov (United States)

    Hye, A.

    1985-01-01

    In space applications, weight, volume and power are critical parameters. Presently liquid freon is used in the radiator planels of the Space Shuttle to dissipate heat. This requires a large amount of freon, large power for pumps, large volume and weight. Use of two-phase flow method to transfer heat can reduce them significantly. A modified commercial vapor compression refrigerator/freezer was sucessfully flown in STS-4 to study the effect of zero-gravity on the system. The duty cycle was about 5 percent higher in flight as compared to that on earth due to low flow velocity in condenser. The vapor Reynolds number at exit was about 4000 as compared to about 12,000. Efforts are underway to design a refrigerator/freezer using an oil-free compressor for Spacelab Mission 4 scheduled to fly in January 1986. A thermal system can be designed for spacecraft using the two-phase flow to transfer heat economically.

  13. Methods for monitoring heat flow intensity in the blast furnace wall

    Directory of Open Access Journals (Sweden)

    L'. Dorčák

    2010-04-01

    Full Text Available In this paper we present the main features of an online system for real-time monitoring of the bottom part of the blast furnace. Firstly, monitoring concerns the furnace walls and furnace bottom temperatures measurement and their visualization. Secondly, monitored are the heat flows of the furnace walls and furnace bottom. In the case of two measured temperatures, the heat flow is calculated using multi-layer implicit difference scheme and in the case of only one measured temperature, the heat flow is calculated using a method based on application of fractional-order derivatives. Thirdly, monitored is the theoretical temperature of the blast furnace combustion process in the area of tuyeres.

  14. A Temperature-Profile Method for Estimating Flow Processes in Geologic Heat Pipes

    Energy Technology Data Exchange (ETDEWEB)

    J.T. Birkholzer

    2005-01-21

    Above-boiling temperature conditions, as encountered, for example, in geothermal reservoirs and in geologic repositories for the storage of heat-producing nuclear wastes, may give rise to strongly altered liquid and gas flow processes in porous subsurface environments. The magnitude of such flow perturbation is extremely hard to measure in the field. We therefore propose a simple temperature-profile method that uses high-resolution temperature data for deriving such information. The energy that is transmitted with the vapor and water flow creates a nearly isothermal zone maintained at about the boiling temperature, referred to as a heat pipe. Characteristic features of measured temperature profiles, such as the differences in the gradients inside and outside of the heat pipe regions, are used to derive the approximate magnitude of the liquid and gas fluxes in the subsurface, for both steady-state and transient conditions.

  15. Long-lasting Science Returns from the Apollo Heat Flow Experiments

    Science.gov (United States)

    Nagihara, S.; Taylor, P. T.; Williams, D. R.; Zacny, K.; Hedlund, M.; Nakamura, Y.

    2012-12-01

    The Apollo astronauts deployed geothermal heat flow instruments at landing sites 15 and 17 as part of the Apollo Lunar Surface Experiments Packages (ALSEP) in July 1971 and December 1972, respectively. These instruments continuously transmitted data to the Earth until September 1977. Four decades later, the data from the two Apollo sites remain the only set of in-situ heat flow measurements obtained on an extra-terrestrial body. Researchers continue to extract additional knowledge from this dataset by utilizing new analytical techniques and by synthesizing it with data from more recent lunar orbital missions such as the Lunar Reconnaissance Orbiter. In addition, lessons learned from the Apollo experiments help contemporary researchers in designing heat flow instruments for future missions to the Moon and other planetary bodies. For example, the data from both Apollo sites showed gradual warming trends in the subsurface from 1971 to 1977. The cause of this warming has been debated in recent years. It may have resulted from fluctuation in insolation associated with the 18.6-year-cycle precession of the Moon, or sudden changes in surface thermal environment/properties resulting from the installation of the instruments and the astronauts' activities. These types of re-analyses of the Apollo data have lead a panel of scientists to recommend that a heat flow probe carried on a future lunar mission reach 3 m into the subsurface, ~0.6 m deeper than the depths reached by the Apollo 17 experiment. This presentation describes the authors' current efforts for (1) restoring a part of the Apollo heat flow data that were left unprocessed by the original investigators and (2) designing a compact heat flow instrument for future robotic missions to the Moon. First, at the conclusion of the ALSEP program in 1977, heat flow data obtained at the two Apollo sites after December 1974 were left unprocessed and not properly archived through NASA. In the following decades, heat flow data

  16. Observation of heat flux and plasma flow in scrape off layer in QUEST

    Energy Technology Data Exchange (ETDEWEB)

    Onchi, T., E-mail: onchi@triam.kyushu-u.ac.jp [RIAM, Kyushu University, 6-1 Kasugakoen, Kasuga, Fukuoka 816-8580 (Japan); Mahira, Y. [IGSES, Kyushu University, 6-1 Kasugakoen, Kasuga, Fukuoka 816-8580 (Japan); Nagaoka, K. [National Institute for Fusion Science,322-6 Oroshi-cho, Toki 509-5292 (Japan); Tashima, S.; Banerjee, S.; Mishra, K. [IGSES, Kyushu University, 6-1 Kasugakoen, Kasuga, Fukuoka 816-8580 (Japan); Idei, H.; Hanada, K.; Nakamura, K.; Fujisawa, A.; Nagashima, Y.; Hasegawa, M. [RIAM, Kyushu University, 6-1 Kasugakoen, Kasuga, Fukuoka 816-8580 (Japan); Matsuoka, K. [National Institute for Fusion Science,322-6 Oroshi-cho, Toki 509-5292 (Japan); Kuzmin, A.; Watanabe, O.; Kawasaki, S.; Nakashima, H.; Higashijima, A. [RIAM, Kyushu University, 6-1 Kasugakoen, Kasuga, Fukuoka 816-8580 (Japan)

    2015-08-15

    Thermal probe with double function of thermocouples and Langmuir probe has been developed, and the initial data observed in far-SOL in QUEST is obtained. Heat flux of megawatt per square meters related to energetic electrons and sonic plasma flow in far-SOL have been observed in the current rump-up phase although no high power inductive force like ohmic winding is applied. The heat flux and the flow are suppressed after the current is built up. In the quasi-steady state, plasma current starts and keeps sawtooth-like oscillation with 20 Hz frequency. The heat flux and the flow in far-SOL have clear responses to the oscillation.

  17. Modelling of fluid flow and heat transfer in a reciprocating compressor

    Science.gov (United States)

    Tuhovcak, J.; Hejcik, J.; Jicha, M.

    2015-08-01

    Efficiency of reciprocating compressor is strongly dependent on several parameters. The most important are valve behaviour and heat transfer. Valves affect the flow through the suction and discharge line. Heat flow from the walls to working fluid increases the work of the cycle. Understanding of these phenomena inside the compressor is a necessary step in the development process. Commercial CFD tools offer wide range of opportunities how to simulate the flow inside the reciprocating compressor nowadays, however they are too demanding in terms of computational time and mesh creation. Several approaches using various correlation equation exist to describe the heat transfer inside the cylinder, however none of them was validated by measurements due to the complicated settings. The goal of this paper is to show a comparison between these correlations using in-house code based on energy balance through the cycle.

  18. Thermal-hydraulic issues of flow boiling and condensation in organic Rankine cycle heat exchangers

    Science.gov (United States)

    Mikielewicz, Jarosław; Mikielewicz, Dariusz

    2012-08-01

    In the paper presented are the issues related to the design and operation of micro heat exchangers, where phase changes can occur, applicable to the domestic micro combined heat and power (CHP) unit. Analysed is the stability of the two-phase flow in such unit. A simple hydraulic model presented in the paper enables for the stability analysis of the system and analysis of disturbance propagation caused by a jump change of the flow rate. Equations of the system dynamics as well as properties of the working fluid are strongly non-linear. A proposed model can be applicable in designing the system of flow control in micro heat exchangers operating in the considered CHP unit.

  19. Numerical Prediction of Heat Transfer Characteristics of Nanofluids in a Minichannel Flow

    Directory of Open Access Journals (Sweden)

    Arjumand Adil

    2014-01-01

    Full Text Available CFD simulation of the heat transfer and pressure drop characteristics of different nanofluids in a minichannel flow has been explained using FLUENT version 6.3.26. Different nanofluids with nanoparticles of Al2O3, CuO, SiO2, and TiO2 have been used in the simulation process. A comparison of the experimental and computational results has been made for the heat transfer and pressure drop characteristics for the case of Al2O3-water nanofluid for the laminar flow. Also, computations have been made by considering Brownian motion as well as without considering Brownian motion of the nanoparticles. After verification of the computational model with the experimental results for Al2O3-water nanofluid, the simulations were performed for the same experimental readings for different nanofluids in the laminar flow regime to find out the heat transfer and pressure drop characteristics.

  20. Pressure drop reduction and heat transfer deterioration of slush nitrogen in triangular and circular pipe flows

    Science.gov (United States)

    Ohira, Katsuhide; Kurose, Kizuku; Okuyama, Jun; Saito, Yutaro; Takahashi, Koichi

    2017-01-01

    Slush fluids such as slush hydrogen and slush nitrogen are characterized by superior properties as functional thermal fluids due to their density and heat of fusion. In addition to allowing efficient hydrogen transport and storage, slush hydrogen can serve as a refrigerant for high-temperature superconducting (HTS) equipment using MgB2, with the potential for synergistic effects. In this study, pressure drop reduction and heat transfer deterioration experiments were performed on slush nitrogen flowing in a horizontal triangular pipe with sides of 20 mm under the conditions of three different cross-sectional orientations. Experimental conditions consisted of flow velocity (0.3-4.2 m/s), solid fraction (0-25 wt.%), and heat flux (0, 10, and 20 kW/m2). Pressure drop reduction became apparent at flow velocities exceeding about 1.3-1.8 m/s, representing a maximum amount of reduction of 16-19% in comparison with liquid nitrogen, regardless of heating. Heat transfer deterioration was seen at flow velocities of over 1.2-1.8 m/s, for a maximum amount of deterioration of 13-16%. The authors of the current study compared the results for pressure drop reduction and heat transfer deterioration in triangular pipe with those obtained previously for circular and square pipes, clarifying differences in flow and heat transfer properties. Also, a correlation equation was obtained between the slush Reynolds number and the pipe friction factor, which is important in the estimation of pressure drop in unheated triangular pipe. Furthermore, a second correlation equation was derived between the modified slush Reynolds number and the pipe friction factor, enabling the integrated prediction of pressure drop in both unheated triangular and circular pipes.