WorldWideScience

Sample records for non-invasive micro-test technique

  1. Techniques for Non-Invasive Monitoring of Arterial Blood Pressure

    Directory of Open Access Journals (Sweden)

    Agnes S. Meidert

    2018-01-01

    Full Text Available Since both, hypotension and hypertension, can potentially impair the function of vital organs such as heart, brain, or kidneys, monitoring of arterial blood pressure (BP is a mainstay of hemodynamic monitoring in acutely or critically ill patients. Arterial BP can either be obtained invasively via an arterial catheter or non-invasively. Non-invasive BP measurement provides either intermittent or continuous readings. Most commonly, an occluding upper arm cuff is used for intermittent non-invasive monitoring. BP values are then obtained either manually (by auscultation of Korotkoff sounds or palpation or automatically (e.g., by oscillometry. For continuous non-invasive BP monitoring, the volume clamp method or arterial applanation tonometry can be used. Both techniques enable the arterial waveform and BP values to be obtained continuously. This article describes the different techniques for non-invasive BP measurement, their advantages and limitations, and their clinical applicability.

  2. Comparison of non-invasive tear film stability measurement techniques.

    Science.gov (United States)

    Wang, Michael Tm; Murphy, Paul J; Blades, Kenneth J; Craig, Jennifer P

    2018-01-01

    Measurement of tear film stability is commonly used to give an indication of tear film quality but a number of non-invasive techniques exists within the clinical setting. This study sought to compare three non-invasive tear film stability measurement techniques: instrument-mounted wide-field white light clinical interferometry, instrument-mounted keratoscopy and hand-held keratoscopy. Twenty-two subjects were recruited in a prospective, randomised, masked, cross-over study. Tear film break-up or thinning time was measured non-invasively by independent experienced examiners, with each of the three devices, in a randomised order, within an hour. Significant correlation was observed between instrument-mounted interferometric and keratoscopic measurements (p 0.05). Tear film stability values obtained from the hand-held device were significantly shorter and demonstrated narrower spread than the other two instruments (all p 0.05). Good clinical agreement exists between the instrument-mounted interferometric and keratoscopic measurements but not between the hand-held device and either of the instrument-mounted techniques. The results highlight the importance of specifying the instrument employed to record non-invasive tear film stability. © 2017 Optometry Australia.

  3. Non-invasive techniques for determining musculoskeleton body composition

    International Nuclear Information System (INIS)

    Cohn, S.H.

    1984-01-01

    In vivo neutron activation analysis, combined with gamma spectrometry, has ushered in a new era of clinical diagnosis and evaluation of therapies, as well as investigation into and modelling of body composition in both normal individuals and patients suffering from various diseases and dysfunctions. Body composition studies have provided baseline data on such vital constituents as nitrogen, potassium and calcium. The non-invasive measurement techniques are particularly suitable for study of the musculo-skeletal changes in body composition. Of particular relevance here is the measurement of calcium loss in astronauts during prolonged space flights

  4. Innovative instrumentation for VVERs based in non-invasive techniques

    International Nuclear Information System (INIS)

    Jeanneau, H.; Favennec, J.M.; Tournu, E.; Germain, J.L.

    2000-01-01

    Nuclear power plants such as VVERs can greatly benefit from innovative instrumentation to improve plant safety and efficiency. In recent years innovative instrumentation has been developed for PWRs with the aim of providing additional measurements of physical parameters on the primary and secondary circuits: the addition of new instrumentation is made possible by using non-invasive techniques such as ultrasonics and radiation detection. These innovations can be adapted for upgrading VVERs presently in operation and also in future VVERs. The following innovative instrumentation for the control, monitoring or testing at VVERs is described: 1. instrumentation for more accurate primary side direct measurements (for a better monitoring of the primary circuit); 2. instrumentation to monitor radioactivity leaks (for a safer plant); 3. instrumentation-related systems to improve the plant efficiency (for a cheaper kWh)

  5. Non-invasive spectroscopic techniques in the diagnosis of non-melanoma skin cancer

    Science.gov (United States)

    Drakaki, E.; Sianoudis, IA; Zois, EN; Makropoulou, M.; Serafetinides, AA; Dessinioti, C.; Stefanaki, E.; Stratigos, AJ; Antoniou, C.; Katsambas, A.; Christofidou, E.

    2017-11-01

    The number of non-melanoma skin cancers is increasing worldwide and has become an important health and economic issue. Early detection and treatment of skin cancer can significantly improve patient outcome. Therefore there is an increase in the demand for proper management and effective non-invasive diagnostic modalities in order to avoid relapses or unnecessary treatments. Although the gold standard of diagnosis for non-melanoma skin cancers is biopsy followed by histopathology evaluation, optical non-invasive diagnostic tools have obtained increased attention. Emerging non-invasive or minimal invasive techniques with possible application in the diagnosis of non-melanoma skin cancers include high-definition optical coherence tomography, fluorescence spectroscopy, oblique incidence diffuse reflectance spectrometry among others spectroscopic techniques. Our findings establish how those spectrometric techniques can be used to more rapidly and easily diagnose skin cancer in an accurate and automated manner in the clinic.

  6. An integrated spectroscopic approach for the non-invasive study of modern art materials and techniques

    Science.gov (United States)

    Rosi, F.; Miliani, C.; Clementi, C.; Kahrim, K.; Presciutti, F.; Vagnini, M.; Manuali, V.; Daveri, A.; Cartechini, L.; Brunetti, B. G.; Sgamellotti, A.

    2010-09-01

    A non-invasive study has been carried out on 18 paintings by Alberto Burri (1915-1995), one of Italy’s most important contemporary painters. The study aims to demonstrate the appropriate and suitable use of portable non-invasive instrumentation for the characterization of materials and techniques found in works dating from 1948 to 1975 belonging to the Albizzini Collection. Sampling of any kind has been forbidden, in order to maintain the integrity of the paintings. Furthermore, the material heterogeneity of each single artwork could potentially result in a poorly representative sampling campaign. Therefore, a non-invasive and in situ analytical approach has been deemed mandatory, notwithstanding the complexity of modern materials and challenging data interpretation. It is the non-invasive nature of the study that has allowed for the acquisition of vast spectral data (a total of about 650 spectra including XRF, mid and near FTIR, micro-Raman and UV-vis absorption and emission spectroscopies). In order to better handle and to extrapolate the most meaningful information from these data, a statistical multivariate analysis, namely principal component analysis (PCA), has been applied to the spectral results. In particular, the possibility of combining elemental and molecular information has been explored by uniting XRF and infrared spectra in one PCA dataset. The combination of complementary spectroscopic techniques has allowed for the characterization of both inorganic and organic pigments, extenders, fillers, and binders employed by Alberto Burri.

  7. Cardiac abnormalities assessed by non-invasive techniques in patients with newly diagnosed idiopathic inflammatory myopathies

    DEFF Research Database (Denmark)

    Diederichsen, Louise Pyndt; Simonsen, Jane Angel; Diederichsen, Axel Cosmus Pyndt

    2015-01-01

    inflammatory myopathies (IIM) by means of non-invasive techniques. METHODS: Fourteen patients with IIM (8 polymyositis, 4 dermatomyositis, 2 cancer-associated dermatomyositis) and 14 gender- and age- matched healthy control subjects were investigated. Participant assessments included a cardiac questionnaire...... in 8 (57%) of the patients compared to none of the controls (pgroup (p=0.01). Two patients had systolic dysfunction, and one diastolic dysfunction...

  8. Intercomparison of techniques for the non-invasive measurement of bone mass

    International Nuclear Information System (INIS)

    Cohn, S.H.

    1981-01-01

    A variety of methods are presently available for the non-invasive measurement of bone mass of both normal individuals and patients with metabolic disorders. Chief among these methods are radiographic techniques such as radiogrammetry, photon absorptiometry, computer tomography, Compton scattering and neutron activation analysis. In this review, the salient features of the bone measurement techniques are discussed along with their accuracy and precision. The advantages and disadvantages of the various techniques for measuring bone mass are summarized. Where possible, intercomparisons are made of the various techniques

  9. Differential Mueller matrix polarimetry technique for non-invasive measurement of glucose concentration on human fingertip.

    Science.gov (United States)

    Phan, Quoc-Hung; Lo, Yu-Lung

    2017-06-26

    A differential Mueller matrix polarimetry technique is proposed for obtaining non-invasive (NI) measurements of the glucose concentration on the human fingertip. The feasibility of the proposed method is demonstrated by detecting the optical rotation angle and depolarization index of tissue phantom samples containing de-ionized water (DI), glucose solutions with concentrations ranging from 0~500 mg/dL and 2% lipofundin. The results show that the extracted optical rotation angle increases linearly with an increasing glucose concentration, while the depolarization index decreases. The practical applicability of the proposed method is demonstrated by measuring the optical rotation angle and depolarization index properties of the human fingertips of healthy volunteers.

  10. Muscle tissue saturation in humans studied with two non-invasive optical techniques: a comparative study

    Science.gov (United States)

    Shaharin, Alfi; Krite Svanberg, Emilie; Ellerström, Ida; Subash, Arman Ahamed; Khoptyar, Dmitry; Andersson-Engels, Stefan; Åkeson, Jonas

    2013-11-01

    Muscle tissue saturation (StO2) has been measured with two non-invasive optical techniques and the results were compared. One of the techniques is widely used in the hospitals - the CW-NIRS technique. The other is the photon timeof- flight spectrometer (pTOFS) developed in the Group of Biophotonics, Lund University, Sweden. The wavelengths used in both the techniques are 730 nm and 810 nm. A campaign was arranged to perform measurements on 21 (17 were taken for comparison) healthy adult volunteers (8 women and 13 men). Oxygen saturations were measured at the right lower arm of each volunteer. To observe the effects of different provocations on the oxygen saturation a blood pressure cuff was attached in the upper right arm. For CW-NIRS, the tissue saturation values were in the range from 70-90%, while for pTOFS the values were in the range from 55-60%.

  11. A novel non-invasive diagnostic sampling technique for cutaneous leishmaniasis.

    Directory of Open Access Journals (Sweden)

    Yasaman Taslimi

    2017-07-01

    Full Text Available Accurate diagnosis of cutaneous leishmaniasis (CL is important for chemotherapy and epidemiological studies. Common approaches for Leishmania detection involve the invasive collection of specimens for direct identification of amastigotes by microscopy and the culturing of promastigotes from infected tissues. Although these techniques are highly specific, they require highly skilled health workers and have the inherent risks of all invasive procedures, such as pain and risk of bacterial and fungal super-infection. Therefore, it is essential to reduce discomfort, potential infection and scarring caused by invasive diagnostic approaches especially for children. In this report, we present a novel non-invasive method, that is painless, rapid and user-friendly, using sequential tape strips for sampling and isolation of DNA from the surface of active and healed skin lesions of CL patients. A total of 119 patients suspected of suffering from cutaneous leishmaniasis with different clinical manifestations were recruited and samples were collected both from their lesions and from uninfected areas. In addition, 15 fungal-infected lesions and 54 areas of healthy skin were examined. The duration of sampling is short (less than one minute and species identification by PCR is highly specific and sensitive. The sequential tape stripping sampling method is a sensitive, non-invasive and cost-effective alternative to traditional diagnostic assays and it is suitable for field studies as well as for use in health care centers.

  12. Post flooding damage assessment of earth dams and historical reservoirs using non-invasive geophysical techniques

    Science.gov (United States)

    Sentenac, Philippe; Benes, Vojtech; Budinsky, Vladimir; Keenan, Helen; Baron, Ron

    2017-11-01

    This paper describes the use of four geophysical techniques to map the structural integrity of historical earth reservoir embankments which are susceptible to natural decay with time. The four techniques that were used to assess the post flood damage were 1. A fast scanning technique using a dipole electromagnetic profile apparatus (GEM2), 2. Electrical Resistivity Tomography (ERT) in order to obtain a high resolution image of the shape of the damaged/seepage zone, 3. Self-Potential surveys were carried out to relate the detected seepage evolution and change of the water displacement inside the embankment, 4. The washed zone in the areas with piping was characterised with microgravimetry. The four geophysical techniques used were evaluated against the case studies of two reservoirs in South Bohemia, Czech Republic. A risk approach based on the Geophysical results was undertaken for the reservoir embankments. The four techniques together enabled a comprehensive non-invasive assessment whereby remedial action could be recommended where required. Conclusions were also drawn on the efficiency of the techniques to be applied for embankments with wood structures.

  13. Combining non-invasive techniques for delimitation and monitoring of chlorinated solvents in groundwater

    Science.gov (United States)

    Sparrenbom, Charlotte; Åkesson, Sofia; Hagerberg, David; Dahlin, Torleif; Holmstrand, Henry; Johansson, Sara

    2016-04-01

    Large numbers of polluted areas cause leakage of hazardous pollutants into our groundwater. Remediated actions are needed in a vast number of areas to prevent degradation of the quality of our water resources. As excavation of polluted masses is problematic as it often moves the pollutants from one site to another (in best case off site treatment is carried out), in-situ remediation and monitoring thereof needs further development. In general, we need to further develop and improve how we retrieve information on the status of the underground system. This is needed to avoid costly and hazardous shipments associated with excavations and to avoid unnecessary exposure when handling polluted masses. Easier, cheaper, more comprehensive and nondestructive monitoring techniques are needed for evaluation of remediation degree, degradation status of the contaminants and the remaining groundwater contaminant plume. We investigate the possibility to combine two investigation techniques, which are invasive to a very low degree and can give a very good visualization and evaluation of pollutant status underground and changes therein in time. The two methods we have combined are Direct Current resistivity and time-domain Induced Polarization tomography (DCIP) and Compound Specific Isotope Analysis (CSIA) and their use within the context of DNAPL contaminated sites. DCIP is a non-invasive and non-destructive geoelectrical measurement method with emerging new techniques for 4D mapping for promising visualization of underground hydrogeochemical structures and spatial distribution of contaminants. The strength of CSIA is that inherent degradation-relatable isotopic information of contaminant molecules remains unaffected as opposed to the commonly used concentration-based studies. Our aim is to evaluate the possibilities of gas sampling on the ground surface for this technique to become non-invasive and usable without interfering ground conditions.Drillings together with soil and

  14. Simple and non-invasive techniques to evaluate the function of CircuLite Synergy.

    Science.gov (United States)

    Mohite, Prashant N; Bowles, Christopher T; Sabashnikov, Anton; Popov, Aron-Frederik; Patil, Nikhil P; Sáez, Diana García; Banner, Nicholas R; Simon, André R

    2014-11-01

    The Synergy CircuLite micropump is a novel partial-support miniature left ventricular assist device that propels 2-3 l/min blood from the left atrium into the right subclavian artery. The ability of currently available investigative modalities to confirm Synergy pump malfunction is limited. The Synergy speed fluctuates periodically (at 10-s intervals) from the baseline to a transient decrease followed by a transient increase (alternating speed algorithm, ASA) with the purpose of changing the blood flow behaviour, thereby reducing thrombogenicity. The aim of this study was to develop a simple non-invasive monitoring technique to assess pump function based on the detection of the ASA in the peripheral microcirculation. Between February 2012 and July 2013, 10 patients with advanced chronic heart failure underwent Synergy implantation at our institution. The pump function was assessed by echocardiography and invasive monitoring according to standard protocols; additionally, the pump speed and power consumption were monitored. During the pump function assessment, the pulse oximeter waveform was recorded from the index fingers of the left and right hand with simultaneous pump auscultation using a stethoscope positioned on the pump (right infra-clavicular pocket). The pulse oximeter waveform was readily detectable from the right and left hand of all study patients. If the Synergy function was normal, there was a significant difference in the morphology of the pulse oximeter waveform from each hand: the ASA algorithm produced a more pronounced variation (giant wave) in the trace from the right hand than from the left. The giant waves invariably coincided with the sound variation associated with the ASA algorithms, which were detected regularly at 10-s intervals. We describe a simple, readily applicable, inexpensive, non-invasive technique that allows evaluation of Synergy pump function and may have diagnostic utility under conditions of suspected pump thrombus

  15. Quantitative evaluation of myocardial perfusion and heart function using a non-invasive double isotope technique

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, W H; Doll, J; Georgi, P [Deutsches Krebsforschungszentrum, Heidelberg (Germany, F.R.). Inst. fuer Nuklearmedizin; Tillmanns, H [Heidelberg Univ. (Germany, F.R.). Innere Medizin 3

    1976-11-01

    This paper describes a non-invasive double nuclide technique for the simultaneous measurement of minimal cardiac transit times (MTT) and regional 'myocardial appearance times' (MAT) using gamma camera and computer. MAT is defined as the time lag between the appearance of an indicator with myocardial affinity in the aortic root and its extraction in the myocardial cells. The extraction can be identified as an increase of the ratio between the count rates of the two nuclides e.g. /sup 201/Tl-chloride and sup(113m)In DTPA. The clinical evaluation of this method allows the following conclusions: 1) MAT, determined over several circumscript myocardial regions permits the qualitative diagnosis of a coronary artery disease with high confidence. 2) Indices of nutritive myocardial blood flow (INF), derived by MAT using several representative areas of myocardium, show a definite correlation to the degree of coronary artery disease. In addition to the localization of infarction and the determination of infarct size, the technique described promises a quantitative evaluation of the regional myocardial perfusion. Simultaneously measured MTT help to assess segmental cardiac performance.

  16. A non-invasive acoustic and vibration analysis technique for evaluation of hip joint conditions.

    Science.gov (United States)

    Glaser, Diana; Komistek, Richard D; Cates, Harold E; Mahfouz, Mohamed R

    2010-02-10

    The performance evaluation of THA outcome is difficult and surgeons often use invasive methods to investigate effectiveness. A non-invasive acoustic and vibration analysis technique has recently been developed for more-in-depth evaluation of in vivo hip conditions. Gait kinematics, corresponding vibration and sound measurement of five THA subjects were analyzed post-operatively using video-fluoroscopy, sound and accelerometer measurements while walking on a treadmill. The sound sensor and a pair of tri-axial accelerometers, externally attached to the pelvic and femoral bone prominences, detected frequencies that are propagated through the femoral head and acetabular cup interactions. A data acquisition system was used to amplify the signal and filter out noise generated by undesired frequencies. In vivo kinematics and femoral head sliding quantified using video fluoroscopy were correlated to the sound and acceleration measurements. Distinct variations between the different subjects were identified. A correlation of sound and acceleration impulses with separation has been achieved. Although, in vivo sounds are quite variable in nature and all correlated well with the visual images. This is the first study to document and correlate visual and audible effects of THA under in-vivo conditions. This study has shown that the development of the acoustic and vibration technique provides a practical method and generates new possibilities for a better understanding of THA performance. Copyright 2009 Elsevier Ltd. All rights reserved.

  17. Primary flow and temperature measurements in PWRS using non-invasive techniques

    International Nuclear Information System (INIS)

    Favennec, J.M.; Jossinet, G.; Thomas, P.

    1995-08-01

    PWR primary flow and temperature measurements are classically done with either indirect or invasive techniques. EDF has developed and installed non-invasive innovative techniques on an industrial nuclear power plant (Chooz N1 type PWR). Primary flow-rate is determined by measurement of velocity of primary water in the hot leg: the time fluctuation of γ-ray activity from Nitrogen-16 (produced by neutron activation of 016) is measured outside of the pipe by two specially-designed detectors. The signals from both detectors are then cross-correlated to determine the transit time of primary water between the two detectors; primary flow-rate is then deduced Primary temperature is determined by measurement of sound velocity in hot and cold leg: two pairs of ultrasonic transducers, installed on pipe outer wall, emit pulses periodically, for which the time of flight along the two pipes diameters are determined. The sound velocity thus computed (diameter over time of flight) is then converted into temperature, by use of a calibration formula relating sound velocity to temperature and pressure. This paper addresses metrological and technical aspects of the methods. Experience feedback on industrial PWRs is also presented. (author). 4 refs., 13 figs

  18. Comparison of non-invasive electrohysterographic recording techniques for monitoring uterine dynamics.

    Science.gov (United States)

    Alberola-Rubio, J; Prats-Boluda, G; Ye-Lin, Y; Valero, J; Perales, A; Garcia-Casado, J

    2013-12-01

    Non-invasive recording of uterine myoelectric activity (electrohysterogram, EHG) could provide an alternative to monitoring uterine dynamics by systems based on tocodynamometers (TOCO). Laplacian recording of bioelectric signals has been shown to give better spatial resolution and less interference than mono- and bipolar surface recordings. The aim of this work was to study the signal quality obtained from monopolar, bipolar and Laplacian techniques in EHG recordings, as well as to assess their ability to detect uterine contractions. Twenty-two recording sessions were carried out on singleton pregnant women during the active phase of labour. In each session the following simultaneous recordings were obtained: internal uterine pressure (IUP), external tension of abdominal wall (TOCO) and EHG signals (5 monopolar and 4 bipolar recordings, 1 discrete approximation to the Laplacian of the potential and 2 estimates of the Laplacian from two active annular electrodes). The results obtained show that EHG is able to detect a higher number of uterine contractions than TOCO. Laplacian recordings give improved signal quality over monopolar and bipolar techniques, reduce maternal cardiac interference and improve the signal-to-noise ratio. The optimal position for recording EHG was found to be the uterine median axis and the lower centre-right umbilical zone. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. State-of-the-art sensor technology in Spain: invasive and non-invasive techniques for monitoring respiratory variables.

    Science.gov (United States)

    Domingo, Christian; Blanch, Lluis; Murias, Gaston; Luján, Manel

    2010-01-01

    The interest in measuring physiological parameters (especially arterial blood gases) has grown progressively in parallel to the development of new technologies. Physiological parameters were first measured invasively and at discrete time points; however, it was clearly desirable to measure them continuously and non-invasively. The development of intensive care units promoted the use of ventilators via oral intubation ventilators via oral intubation and mechanical respiratory variables were progressively studied. Later, the knowledge gained in the hospital was applied to out-of-hospital management. In the present paper we review the invasive and non-invasive techniques for monitoring respiratory variables.

  20. A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue

    Directory of Open Access Journals (Sweden)

    Mohamed R. Al-Mulla

    2011-03-01

    Full Text Available Muscle fatigue is an established area of research and various types of muscle fatigue have been investigated in order to fully understand the condition. This paper gives an overview of the various non-invasive techniques available for use in automated fatigue detection, such as mechanomyography, electromyography, near-infrared spectroscopy and ultrasound for both isometric and non-isometric contractions. Various signal analysis methods are compared by illustrating their applicability in real-time settings. This paper will be of interest to researchers who wish to select the most appropriate methodology for research on muscle fatigue detection or prediction, or for the development of devices that can be used in, e.g., sports scenarios to improve performance or prevent injury. To date, research on localised muscle fatigue focuses mainly on the clinical side. There is very little research carried out on the implementation of detecting/predicting fatigue using an autonomous system, although recent research on automating the process of localised muscle fatigue detection/prediction shows promising results.

  1. A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue

    Science.gov (United States)

    Al-Mulla, Mohamed R.; Sepulveda, Francisco; Colley, Martin

    2011-01-01

    Muscle fatigue is an established area of research and various types of muscle fatigue have been investigated in order to fully understand the condition. This paper gives an overview of the various non-invasive techniques available for use in automated fatigue detection, such as mechanomyography, electromyography, near-infrared spectroscopy and ultrasound for both isometric and non-isometric contractions. Various signal analysis methods are compared by illustrating their applicability in real-time settings. This paper will be of interest to researchers who wish to select the most appropriate methodology for research on muscle fatigue detection or prediction, or for the development of devices that can be used in, e.g., sports scenarios to improve performance or prevent injury. To date, research on localised muscle fatigue focuses mainly on the clinical side. There is very little research carried out on the implementation of detecting/predicting fatigue using an autonomous system, although recent research on automating the process of localised muscle fatigue detection/prediction shows promising results. PMID:22163810

  2. Why use Finapres or Portapres rather than intra-arterial or intermittent non-invasive techniques of blood pressure measurement?

    NARCIS (Netherlands)

    Langewouters, G. J.; Settels, J. J.; Roelandt, R.; Wesseling, K. H.

    1998-01-01

    In the clinic, blood pressure is measured almost exclusively using non-invasive intermittent techniques, of which the auscultatory (Riva-Rocci/Korotkoff, RRK) and the computerized oscillometric method are most often used. However, both methods only provide a momentary value. In addition, the

  3. Non-invasive techniques for revealing the palette of the Romantic painter Francesco Hayez

    Science.gov (United States)

    Rampazzi, Laura; Brunello, Valentina; Corti, Cristina; Lissoni, Elena

    2017-04-01

    This paper describes the first systematic analysis of the palette of Francesco Hayez, one of the most outstanding artists of European Romanticism, whose painting technique has never been extensively investigated despite the plethora of artistic studies. He lived in a particular moment in the history of painting, as in the first half of the 19th century many synthetic pigments were available, also in tin tubes, but traditional materials were still used. Sixteen paintings on canvas and on panels, created between 1823 and 1868, were analyzed in situ through non-invasive techniques (infrared reflectography and infrared reflection spectroscopy). Imaging investigation provided clues on painting technique, revealing some cases of pentimenti and underdrawings. A preliminary survey was carried out on a hundred pure pigments used up to the 19th century and on new synthetic colours, in order to attain reference spectra for the interpretation of painting spectra. The portable infrared instrument provided insight into Hayez's painting materials, identifying barite, ivory black, lead-tin yellow, Naples yellow, ochres, Prussian blue, and white lead. The pigments were often blended, to obtain a unique fabric appearance or to attain cold shades. The results pointed to a siccative oil as a binder, mixed with white lead so that it could act as a catalyzer in polymerization reactions, and in some cases with a proteinaceous binder and resins. The preparation was made with gypsum and white lead mixed with a siccative oil. The results showed that the artist used a typical traditional palette, throughout his career, in order to lead to brilliant colours and with long-term stability. Anyway, the possible presence of cobalt blue in a few paintings suggests that Hayez had probably started testing the new colours, since the second decade of 19th century.

  4. Joint application of non-invasive techniques to characterize the dynamic behaviuor of engineering structures

    Science.gov (United States)

    Gallipoli, M. R.; Perrone, A.; Stabile, T. A.; Ponzo, F. C.; Ditommaso, R.

    2012-04-01

    The systematic monitoring of strategic civil infrastructures such as bridges, large dams or high-rise buildings in order to ensure their structural stability is a strategic issue particularly in earthquake-prone regions. Nevertheless, in areas less exposed to seismic hazard, the monitoring is also an important tool for civil engineers, for instance if they have to deal with structures exposed to heavy operational demands for extended periods of time and whose structural integrity might be in question or at risk. A continuous monitoring of such structures allows the identification of their fundamental response characteristics and the changes of these over time, the latter representing indicators for potential structural degradation. The aim of this paper is the estimation of fundamental dynamic parameters of some civil infrastructures by the joint application of fast executable, non-invasive techniques such as the Ambient Noise Standard Spectral Ratio, and Ground-Based microwave Radar Interferometer techniques. The joint approach combine conventional, non-conventional and innovative techniques in order to set up a non destructive evaluation procedure allowing for a multi-sensing monitoring at a multi-scale and multi-depth levels (i.e. with different degrees of spatial resolution and different subsurface depths). In particular, techniques based on ambient vibration recordings have become a popular tool for characterizing the seismic response and state-of-health of strategic civil infrastructure. The primary advantage of these approaches lies in the fact that no transient earthquake signals or even active excitation of the structure under investigation are required. The microwave interferometry radar technology, it has proven to be a powerful remote sensing tool for vibration measurement of structures, such as bridge, heritage architectural structures, vibrating stay cables, and engineering structures. The main advantage of this radar technique is the possibility to

  5. Evaluation of biolistic gene transfer methods in vivo using non-invasive bioluminescent imaging techniques

    Directory of Open Access Journals (Sweden)

    Daniell Henry

    2011-06-01

    Full Text Available Abstract Background Gene therapy continues to hold great potential for treating many different types of disease and dysfunction. Safe and efficient techniques for gene transfer and expression in vivo are needed to enable gene therapeutic strategies to be effective in patients. Currently, the most commonly used methods employ replication-defective viral vectors for gene transfer, while physical gene transfer methods such as biolistic-mediated ("gene-gun" delivery to target tissues have not been as extensively explored. In the present study, we evaluated the efficacy of biolistic gene transfer techniques in vivo using non-invasive bioluminescent imaging (BLI methods. Results Plasmid DNA carrying the firefly luciferase (LUC reporter gene under the control of the human Cytomegalovirus (CMV promoter/enhancer was transfected into mouse skin and liver using biolistic methods. The plasmids were coupled to gold microspheres (1 μm diameter using different DNA Loading Ratios (DLRs, and "shot" into target tissues using a helium-driven gene gun. The optimal DLR was found to be in the range of 4-10. Bioluminescence was measured using an In Vivo Imaging System (IVIS-50 at various time-points following transfer. Biolistic gene transfer to mouse skin produced peak reporter gene expression one day after transfer. Expression remained detectable through four days, but declined to undetectable levels by six days following gene transfer. Maximum depth of tissue penetration following biolistic transfer to abdominal skin was 200-300 μm. Similarly, biolistic gene transfer to mouse liver in vivo also produced peak early expression followed by a decline over time. In contrast to skin, however, liver expression of the reporter gene was relatively stable 4-8 days post-biolistic gene transfer, and remained detectable for nearly two weeks. Conclusions The use of bioluminescence imaging techniques enabled efficient evaluation of reporter gene expression in vivo. Our results

  6. Application of magnetic resonance elastography as a non-invasive technique for diagnosis of liver fibrosis

    Directory of Open Access Journals (Sweden)

    YANG Minglei

    2016-03-01

    Full Text Available At present, liver biopsy is the gold standard for the diagnosis and grading of liver fibrosis, but its limitations have been widely acknowledged. The non-invasive detection methods are needed in clinical practice, and at present, magnetic resonance elastography (MRE is a hot research topic. This article reviews the advances in the clinical application of MRE in related fields, and studies have shown that MRE has a high diagnostic value due to its high sensitivity and specificity in the diagnosis and grading of liver fibrosis and an area under the receiver operating characteristic curve as high as 0.95. Compared with serological and other imaging diagnostic methods, MRE can determine fibrosis stage more accurately and has good reproducibility and objectivity. MRE can be widely applied in all patients except those with hemochromatosis, with special advantages in the diagnosis for patients with obesity and ascites, and can make up for the disadvantages of other methods. This article points out that MRE may become the best non-invasive method for the assessment of liver fibrosis, especially advanced fibrosis.

  7. Laser induced fluorescence thermometry (LIF-T) as a non-invasive temperature measurement technique for thermal hydraulic experiments

    Energy Technology Data Exchange (ETDEWEB)

    Strack, J.; Leung, K.; Walker, A., E-mail: strackj@mcmaster.ca [McMaster Univ., Hamilton, ON (Canada)

    2014-07-01

    Laser induced fluorescence (LIF) is an experimental technique whereby a scalar field in a fluid system is measured optically from the fluorescence intensity of a tracer dye following excitation by laser light. For laser induced fluorescence thermometry (LIF-T), a temperature sensitive dye is used. Through the use of a temperature sensitive tracer dye, sheet laser optics, optical filters, and photography, a 2D temperature field can be measured non-invasively. An experiment to test the viability of using LIF-T for macroscopic thermal hydraulic experiments was developed and tested. A reference calibration curve to relate fluorescence measurements to temperature is presented. (author)

  8. Non-invasive dendrochronology of late-medieval objects in Oslo: refinement of a technique and discoveries

    Science.gov (United States)

    Daly, Aoife; Streeton, Noëlle L. W.

    2017-06-01

    A technique for non-invasive dendrochronological analysis of oak was developed for archaeological material, using an industrial CT scanner. Since 2013, this experience has been extended within the scope of the research project `After the Black Death: Painting and Polychrome Sculpture in Norway'. The source material for the project is a collection of late-medieval winged altarpieces, shrines, polychrome sculpture, and fragments from Norwegian churches, which are owned by the Museum of Cultural History, University of Oslo. The majority cannot be sampled, and many are too large to fit into the CT scanner. For these reasons, a combined approach was adopted, utilizing CT scanning where possible, but preceded by an `exposed-wood' imaging technique. Both non-invasive techniques have yielded reliable results, and CT scanning has confirmed the reliability of the imaging technique alone. This paper presents the analytical methods, along with results from two of the 13 objects under investigation. Results for reliable dates and provenances provide new foundations for historical interpretations.

  9. On the advance of non-invasive techniques implementation for monitoring moisture distribution in cultural heritage: a case study

    Science.gov (United States)

    Inmaculada Martínez Garrido, María; Gómez Heras, Miguel; Fort González, Rafael; Valles Iriso, Javier; José Varas Muriel, María

    2015-04-01

    This work presents a case study developed in San Juan Bautista church in Talamanca de Jarama (12th -16th Century), which have been selected as an example of a historical church with a complex construction with subsequent combination of architectural styles and building techniques and materials. These materials have a differential behavior under the influence of external climatic conditions and constructive facts. Many decay processes related to humidity are affecting the building's walls and also have influence in the environmental dynamics inside the building. A methodology for monitoring moisture distribution on stone and masonry walls and floors was performed with different non-invasive techniques as thermal imaging, wireless sensor networks (WSN), portable moisture meter, electrical resistivity tomography (ERT) and ground-penetrating radar (GPR), in order to the evaluate the effectiveness of these techniques for the knowledge of moisture distribution inside the walls and the humidity origin. North and south oriented sections, both on walls and floors, were evaluated and also a general inspection in the church was carried out with different non-invasive techniques. This methodology implies different monitoring stages for a complete knowledge of the implication of outdoors and indoors conditions on the moisture distribution. Each technique is evaluated according to its effectiveness in the detection of decay processes and maintenance costs. Research funded by Geomateriales (S2013/MIT-2914) and Deterioration of stone materials in the interior of historic buildings as a result induced variation of its microclimate (CGL2011-27902) projects. The cooperation received from the Complutense University of Madrid's Research Group Alteración y Conservación de los Materiales Pétreos del Patrimonio (ref. 921349), the Laboratory Network in Science and Technology for Heritage Conservation (RedLabPat, CEI Moncloa) and the Diocese of Alcalá is gratefully acknowledged. MI Mart

  10. Burn-injured tissue detection for debridement surgery through the combination of non-invasive optical imaging techniques.

    Science.gov (United States)

    Heredia-Juesas, Juan; Thatcher, Jeffrey E; Lu, Yang; Squiers, John J; King, Darlene; Fan, Wensheng; DiMaio, J Michael; Martinez-Lorenzo, Jose A

    2018-04-01

    The process of burn debridement is a challenging technique requiring significant skills to identify the regions that need excision and their appropriate excision depths. In order to assist surgeons, a machine learning tool is being developed to provide a quantitative assessment of burn-injured tissue. This paper presents three non-invasive optical imaging techniques capable of distinguishing four kinds of tissue-healthy skin, viable wound bed, shallow burn, and deep burn-during serial burn debridement in a porcine model. All combinations of these three techniques have been studied through a k-fold cross-validation method. In terms of global performance, the combination of all three techniques significantly improves the classification accuracy with respect to just one technique, from 0.42 up to more than 0.76. Furthermore, a non-linear spatial filtering based on the mode of a small neighborhood has been applied as a post-processing technique, in order to improve the performance of the classification. Using this technique, the global accuracy reaches a value close to 0.78 and, for some particular tissues and combination of techniques, the accuracy improves by 13%.

  11. Non-invasive measurement of calcium and phosphorus in human body by NAA technique

    International Nuclear Information System (INIS)

    Wang Haiying; Luo Xianqing; Huang Hanqiao

    1995-01-01

    A system of measuring calcium and phosphorus in human legs has been developed by the use of partial-body neutron activation analysis and partial-body counting technique. The results are compared for the normals and osteoporotic patients

  12. Non invasive techniques for the study of the extracranial carotid arterial system

    International Nuclear Information System (INIS)

    Ameneiro Perez, Santiago; Alvarez Sanchez, Jose Antonio; Aldama Figueroa, Alfredo

    2000-01-01

    A review of the noninvasive diagnostic techniques that have been historically used to detect the stenoocclussive lesions of the extracranial carotid arterial system is made. The technological development and the new therapeutic criteria to prevent strokes caused by these lesions have encouraged research in this field. A review of the most used techniques at present: mode B ultrasound, duplex ultrasound and color duplex ultrasound, as well as of the advantages and disadvantages of each one is made. Nowadays, there are hemodynamic criteria together with these techniques that evaluate the stenosis degrees and the characteristics of the lesions with accuracy enough to substitute in most of the cases the invasive and more expensive diagnostic angiographic methods

  13. Non-invasive techniques for measuring body composition: state of the art and future prospects

    Energy Technology Data Exchange (ETDEWEB)

    Cohn, S.H.

    1985-01-01

    In the past 20 years, in vivo analysis of body elements by neutron activation has become an important tool in medical research. In particular, it provides a much needed means to make quantitative assessments of body composition of human beings in vivo. The data are useful both for basic physiological understanding and for diagnosis and management of a variety of diseases and disorders. This paper traces the development of the in vivo neutron activation technique from basic systems to the present state of the art facilities. A scan of some of the numerous clinical applications that have been made with this technique, reveals the broad potentialities of in vivo neutron activation. The paper also considers alternative routes of future development and raises some of the questions now faced in making the techniques more widely available to both medical practitioners and medical investigators. In vivo neutron activation has opened a new era of both clinical diagnosis and therapy evaluation, and investigation into the modelling of body composition. The techniques are new, but it is already clear that considerable strides can be made in increasing accuracy and precision, increasing the number of elements susceptible to measurement, and reducing the dose required for the measurement. 18 refs., 7 figs.

  14. Non-invasive techniques for measuring body composition: state of the art and future prospects

    International Nuclear Information System (INIS)

    Cohn, S.H.

    1985-01-01

    In the past 20 years, in vivo analysis of body elements by neutron activation has become an important tool in medical research. In particular, it provides a much needed means to make quantitative assessments of body composition of human beings in vivo. The data are useful both for basic physiological understanding and for diagnosis and management of a variety of diseases and disorders. This paper traces the development of the in vivo neutron activation technique from basic systems to the present state of the art facilities. A scan of some of the numerous clinical applications that have been made with this technique, reveals the broad potentialities of in vivo neutron activation. The paper also considers alternative routes of future development and raises some of the questions now faced in making the techniques more widely available to both medical practitioners and medical investigators. In vivo neutron activation has opened a new era of both clinical diagnosis and therapy evaluation, and investigation into the modelling of body composition. The techniques are new, but it is already clear that considerable strides can be made in increasing accuracy and precision, increasing the number of elements susceptible to measurement, and reducing the dose required for the measurement. 18 refs., 7 figs

  15. Non invasive blood flow assessment in diabetic foot ulcer using laser speckle contrast imaging technique

    Science.gov (United States)

    Jayanthy, A. K.; Sujatha, N.; Reddy, M. Ramasubba; Narayanamoorthy, V. B.

    2014-03-01

    Measuring microcirculatory tissue blood perfusion is of interest for both clinicians and researchers in a wide range of applications and can provide essential information of the progress of treatment of certain diseases which causes either an increased or decreased blood flow. Diabetic ulcer associated with alterations in tissue blood flow is the most common cause of non-traumatic lower extremity amputations. A technique which can detect the onset of ulcer and provide essential information on the progress of the treatment of ulcer would be of great help to the clinicians. A noninvasive, noncontact and whole field laser speckle contrast imaging (LSCI) technique has been described in this paper which is used to assess the changes in blood flow in diabetic ulcer affected areas of the foot. The blood flow assessment at the wound site can provide critical information on the efficiency and progress of the treatment given to the diabetic ulcer subjects. The technique may also potentially fulfill a significant need in diabetic foot ulcer screening and management.

  16. INVASIVE AND NON-INVASIVE TECHNIQUES FOR DETECTING PORTAL HYPERTENSION AND PREDICTING VARICEAL BLEEDING IN CIRRHOSIS: A REVIEW

    Science.gov (United States)

    Zardi, Enrico Maria; Di Matteo, Francesco Maria; Pacella, Claudio Maurizio; Sanyal, Arun J

    2016-01-01

    Portal hypertension is a severe syndrome that may derive from pre-sinusoidal, sinusoidal and post-sinusoidal causes. As a consequence, several complications (i.e., ascites, oesophageal varices) may develop. In sinusoidal portal hypertension, hepatic venous pressure gradient (HVPG) is a reliable method for defining the grade of portal pressure, establishing the effectiveness of the treatment and predicting the occurrence of complications; however, some questions exist regarding its ability to discriminate bleeding from nonbleeding varices in cirrhotic patients. Other imaging techniques (transient elastography, endoscopy, endosonography and duplex Doppler sonography) for assessing causes and complications of portal hypertensive syndrome are available and may be valuable for the management of these patients. In this review, we evaluate invasive and non-invasive techniques currently employed to obtain a clinical prediction of deadly complications, such as variceal bleeding in patients affected by sinusoidal portal hypertension, in order to create a diagnostic algorithm to manage them. Again, HVPG appears to be the reference standard to evaluate portal hypertension and monitor the response to treatment, but its ability to predict several complications and support management decisions might be further improved through the diagnostic combination with other imaging techniques. PMID:24328372

  17. Towards non-invasive diagnostic techniques for early detection of acute renal transplant rejection: A review

    Directory of Open Access Journals (Sweden)

    Elizabeth Hollis

    2017-03-01

    Full Text Available The kidney is a very important complicated filtering organ of the body. When the kidney reaches stage 5 chronic kidney disease, end stage renal failure, the preeminent therapy is renal transplantation. Although it is the best form of treatment, lack of kidney donors is still challenging. Therefore, all efforts should be employed to prolong the survival rate of the transplanted kidney. However, graft dysfunction (e.g., acute rejection is one of the serious barriers to long term kidney transplant survival. Currently, graft dysfunction’s gold standard of diagnosis is renal biopsy. Although renal biopsy is helpful, it is not preferred due to its invasive nature, high morbidity rates, and expensiveness. Therefore, noninvasive imaging techniques have become the subject of extensive research and interest, giving a strong promise to replace, or at least to decrease, biopsy usage in diagnosing graft dysfunction. This survey will discuss not only the current diagnosis and treatment of graft dysfunction but also the state-of-the-art imaging techniques in detecting acute renal transplant rejection.

  18. Improving Perioperative Outcomes Through Minimally Invasive and Non-invasive Hemodynamic Monitoring Techniques

    Directory of Open Access Journals (Sweden)

    Takashige Yamada

    2018-05-01

    Full Text Available An increasing number of patients require precise intraoperative hemodynamic monitoring due to aging and comorbidities. To prevent undesirable outcomes from intraoperative hypotension or hypoperfusion, appropriate threshold settings are required. These setting can vary widely from patient to patient. Goal-directed therapy techniques allow for flow monitoring as the standard for perioperative fluid management. Based on the concept of personalized medicine, individual assessment and treatment are more advantageous than conventional or uniform interventions. The recent development of minimally and noninvasive monitoring devices make it possible to apply detailed control, tracking, and observation of broad patient populations, all while reducing adverse complications. In this manuscript, we review the monitoring features of each device, together with possible advantages and disadvantages of their use in optimizing patient hemodynamic management.

  19. Non-invasive technique to measure biogeochemical parameters (pH and O2) in a microenvironment: Design and applications

    Science.gov (United States)

    Li, Biting; Seliman, Ayman; Pales, Ashley; Liang, Weizhen; Sams, Allison; Darnault, Christophe; Devol, Timothy

    2017-04-01

    The primary objectives of this research are to do the pH and O2 sensor foils calibration and then to test them in applications. Potentially, this project can be utilized to monitor the fate and transport of radionuclides in porous media. The information for physical and chemical parameters (e.g. pH and O2) is crucial to know when determining contaminants' behavior and transport in the environment. As a non-invasive method, optical imaging technique using a DSLR camera could capture data on the foil when it fluoresces, and gives a high temporal and spatial resolution during the experimental period. The calibration procedures were done in cuvettes in a row. The preliminary experiments could measure pH value in the range from 4.5 to 7.5, and O2 concentration from 0 mg/L to 20.74 mg/L. Applications of sensor foils have involved nano zero valent and acid rain experiments in order to obtain a gradient of parameter changes.

  20. Non-invasive Florentine Renaissance Panel Painting Replica Structures Investigation by Using Terahertz Time-Domain Imaging (THz-TDI) Technique

    DEFF Research Database (Denmark)

    Dandolo, Corinna Ludovica Koch; Picollo, Marcello; Cucci, Costanza

    2016-01-01

    The potentials of the Terahertz Time-Domain Imaging (THz-TDI) technique for a non-invasive inspection of panel paintings have been considered in detail. The THz-TD data acquired on a replica of a panel painting made in imitation of Italian Renaissance panel paintings were processed in order to pr...

  1. PET/CT colonography: a novel non-invasive technique for assessment of extent and activity of ulcerative colitis

    Energy Technology Data Exchange (ETDEWEB)

    Das, Chandan J.; Sharma, Raju [All India Institute of Medical Sciences, Department of Radiodiagnosis, New Delhi (India); Makharia, Govind K.; Tiwari, Rajeew P. [All India Institute of Medical Sciences, Department of Gastroenterology and Human Nutrition, New Delhi (India); Kumar, Rakesh; Kumar, Rajender; Malhotra, Arun [All India Institute of Medical Sciences, Department of Nuclear Medicine, New Delhi (India)

    2010-04-15

    Extent of involvement and activity of ulcerative colitis (UC) is best evaluated by colonoscopy. Colonoscopy however carries risk during acute exacerbation. We investigated the utility of PET/CT colonography for assessment of extent and activity of UC. Within a 1-week window, 15 patients with mild to moderately active UC underwent colonoscopy and PET/CT colonography 60 min after injection of 10 mCi of {sup 18}F-fluorodeoxyglucose (FDG). PET activity score based on the amount of FDG uptake and endoscopic mucosal activity in seven colonic segments of each patient was recorded. The mean maximum standardized uptake value (SUV{sub max}) of seven segments was compared with activity in liver. A PET activity grade of 0, 1, 2 or 3 was assigned to each region depending upon their SUV{sub max} ratio (colon segment to liver). The extent of disease was left-sided colitis in five and pancolitis in ten. The mean Ulcerative Colitis Disease Activity Index (UCDAI) was 7.6. The number of segments involved as per colonoscopic evaluation and PET/CT colonography was 67 and 66, respectively. There was a good correlation for extent evaluation between the two modalities (kappa 55.3%, p = 0.02). One patient had grade 0 PET activity, nine had grade 2 and five had grade 3 PET activity. In six patients, there was one to one correlation between PET activity grades with that of endoscopic grade. One patient showed activity in the sacroiliac joint suggesting active sacroiliitis. PET/CT colonography is a novel non-invasive technique for the assessment of extent and activity of the disease in patients with UC. (orig.)

  2. A reliable genetic technique for sex determination of giant panda (Ailuropoda melanoleuca) from non-invasively collected hair samples

    NARCIS (Netherlands)

    Durnin, Matthew E.; Palsboll, Per J.; Ryder, Oliver A.; McCullough, Dale R.

    Extractions from non-invasive hair samples usually yield low amounts of highly degraded DNA. Previously developed mammal molecular sexing methods were not designed with such sub-optimal conditions in mind. We developed a simple and reliable PCR-based sexing method aimed at degraded, low yield DNA

  3. Comparison of two non-invasive methods of microbial analysis in surgery practice: incision swabbing and the indirect imprint technique.

    Science.gov (United States)

    Chovanec, Zdenek; Veverkova, Lenka; Votava, Miroslav; Svoboda, Jiri; Jedlicka, Vaclav; Capov, Ivan

    2014-12-01

    A variety of methods exist to take samples from surgical site infections for cultivation; however, an unambiguous and suitable method has not yet been defined. The aim of our retrospective non-randomized study was to compare two non-invasive techniques of sampling material for microbiologic analysis in surgical practice. We compared bacteria cultured from samples obtained with the use of the swab technique, defined in our study as the gold standard, with the indirect imprint technique. A cotton-tipped swab (Copan, Brescia, Italy) was used; the imprints were taken using Whatman no. 4 filter paper (Macherey-Nagal, Duren, Germany) cut into 5×5 cm pieces placed on blood agar in a Petri dish. To culture the microorganisms in the microbiology laboratory, we used blood agar, UriSelect 4 medium (Bio-Rad, Marnes-la-Coquette, France), and a medium with sodium chloride (blood agar with salt). After careful debridement, a sample was taken from the incision surface by swab and subsequently the same area of the surface was imprinted onto filter paper. The samples were analyzed in the microbiology laboratory under standard safety precautions. The cultivation results of the two techniques were processed statistically using contingency tables and the McNemar test. Those samples that were simultaneously cultivation-positive by imprint and -negative by swabbing were processed in greater detail. Over the period between October 2008 and March 2013, 177 samples from 70 patients were analyzed. Sampling was carried out from 42 males and 28 females. One hundred forty-six samples were from incisions after operations (21 samples from six patients after operation on the thoracic cavity, 73 samples from 35 patients after operation on the abdominal cavity combined with the gastrointestinal tract, 52 samples from 19 patients with other surgical site infections not included above) and 31 samples from 11 patients with no post-operative infection. One patient had a sample taken both from a post

  4. Integration of non-invasive biometrics with sensory analysis techniques to assess acceptability of beer by consumers.

    Science.gov (United States)

    Gonzalez Viejo, Claudia; Fuentes, Sigfredo; Howell, Kate; Torrico, Damir D; Dunshea, Frank R

    2018-03-05

    Traditional sensory tests rely on conscious and self-reported responses from participants. The integration of non-invasive biometric techniques, such as heart rate, body temperature, brainwaves and facial expressions can gather more information from consumers while tasting a product. The main objectives of this study were i) to assess significant differences between beers for all conscious and unconscious responses, ii) to find significant correlations among the different variables from the conscious and unconscious responses and iii) to develop a model to classify beers according to liking using only the unconscious responses. For this study, an integrated camera system with video and infrared thermal imagery (IRTI), coupled with a novel computer application was used. Videos and IRTI were automatically obtained while tasting nine beers to extract biometrics (heart rate, temperature and facial expressions) using computer vision analysis. Additionally, an EEG mobile headset was used to obtain brainwave signals during beer consumption. Consumers assessed foam, color, aroma, mouthfeel, taste, flavor and overall acceptability of beers using a 9-point hedonic scale with results showing a higher acceptability for beers with higher foamability and lower bitterness. i) There were non-significant differences among beers for the emotional and physiological responses, however, significant differences were found for the cognitive and self-reported responses. ii) Results from principal component analysis explained 65% of total data variability and, along with the covariance matrix (p sensory responses of participants and the biometric data obtained. There was a negative correlation between body temperature and liking of foam height and stability, and a positive correlation between theta signals and bitterness. iii) Artificial neural networks were used to develop three models with high accuracy to classify beers according to level of liking (low and high) of three sensory

  5. Apport des techniques non invasives dans le suivi de l'atteinte cardiaque dans la maladie de Steinert

    OpenAIRE

    Luporsi , Jean-Dominique

    2008-01-01

    The first part of this personal work is a review focused on epidemiology, genetic bases,clinical description and treatment of Steinert's disease. The second part exposes a personal trial based on the recruitment of 102 patients coming from the orphan diseases and the neurology departments of the Nancy universitary hospital, who are then sent to the cardiology department for systematic non-invasive investigations in the framework of their myotonicdystrophy. A comparison is made between Our res...

  6. A pilot study using laser-based technique for non-invasive diagnostics of hypertensive conditions in mice

    Science.gov (United States)

    Litvinova, Karina S.; Ahmad, Shakil; Wang, Keqing; Rafailov, Ilya E.; Sokolovski, Sergei G.; Zhang, Lin; Rafailov, Edik U.; Ahmed, Asif

    2016-02-01

    Endothelial dysfunction is directly linked to preeclampsia, a maternal hypertensive condition that is life threating for both the mother and the baby. Epidemiological studies show that women with a history of pre-eclampsia have an elevated risk for cardiovascular disease. Here we report a new non-invasive diagnostic test for preeclampsia in mice that allows us to non-invasively assess the condition of the animals during the experiment and treatment in established models of preeclampsia. A laser-based multifunctional diagnostics system (LAKK-M) was chosen to carry out non-invasive analysis of multiple parameters. The device was used to simultaneously record the microcirculatory blood flow and oxygen saturation, as well as fluorescence levels of endogenous fluorophores. Preliminary experiments were conducted on adenoviral (Ad-)- mediated overexpression of sFlt-1 (Ad-sFlt-1) to mimic preeclampsialike symptoms in mice. The recorded data displayed the ability of the LAKK-M diagnostics device to detect significant differences in perfusion measurements between the control and Ad-sFlt-1 treatment. Preliminary results provide a potential avenue to employ these diagnostics technology to monitor and aid in maintaining control of live animal conditions throughout the experiment and treatment.

  7. Using non-invasive molecular spectroscopic techniques to detect unique aspects of protein Amide functional groups and chemical properties of modeled forage from different sourced-origins.

    Science.gov (United States)

    Ji, Cuiying; Zhang, Xuewei; Yu, Peiqiang

    2016-03-05

    The non-invasive molecular spectroscopic technique-FT/IR is capable to detect the molecular structure spectral features that are associated with biological, nutritional and biodegradation functions. However, to date, few researches have been conducted to use these non-invasive molecular spectroscopic techniques to study forage internal protein structures associated with biodegradation and biological functions. The objectives of this study were to detect unique aspects and association of protein Amide functional groups in terms of protein Amide I and II spectral profiles and chemical properties in the alfalfa forage (Medicago sativa L.) from different sourced-origins. In this study, alfalfa hay with two different origins was used as modeled forage for molecular structure and chemical property study. In each forage origin, five to seven sources were analyzed. The molecular spectral profiles were determined using FT/IR non-invasive molecular spectroscopy. The parameters of protein spectral profiles included functional groups of Amide I, Amide II and Amide I to II ratio. The results show that the modeled forage Amide I and Amide II were centered at 1653 cm(-1) and 1545 cm(-1), respectively. The Amide I spectral height and area intensities were from 0.02 to 0.03 and 2.67 to 3.36 AI, respectively. The Amide II spectral height and area intensities were from 0.01 to 0.02 and 0.71 to 0.93 AI, respectively. The Amide I to II spectral peak height and area ratios were from 1.86 to 1.88 and 3.68 to 3.79, respectively. Our results show that the non-invasive molecular spectroscopic techniques are capable to detect forage internal protein structure features which are associated with forage chemical properties. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Non-destructive and non-invasive analyses shed light on the realization technique of ancient polychrome prints

    Science.gov (United States)

    Striová, Jana; Coccolini, Gabriele; Micheli, Sara; Lofrumento, Cristiana; Galeotti, Monica; Cagnini, Andrea; Castellucci, Emilio Mario

    2009-08-01

    Five polychrome prints representing famous painters, such as Albrecht Dürer, were analyzed using a non-destructive and non-invasive methodology as required by the artwork typology. The diagnostic strategy includes X-ray fluorescence (XRF), reflectance micro-infrared (μFTIR) and micro-Raman (μRaman) spectroscopy. These prints were realized with a la poupée method that involves application of the polychrome inks on a single copper plate, before the printing process. A broad range of compounds (i.e., cinnabar, red lead, white lead, umber earth, hydrated calcium sulfate, calcium carbonate, amorphous carbon, and Prussian blue) was employed as chalcographic inks, using linseed oil as a binding medium. Gamboge was identified in the delicate finishing brush touches realized in watercolor.

  9. Non-invasive method to detect the changes of glucose concentration in whole blood using photometric technique.

    Science.gov (United States)

    Rajan, Shiny Amala Priya; Towe, Bruce C

    2014-01-01

    A non-invasive method is developed to monitor rapid changes in blood glucose levels in diabetic patients. The system depends on an optical cell built with a LED that emits light of wavelength 535nm, which is a peak absorbance of hemoglobin. As the glucose concentration in blood decreases, its osmolarity also decreases and the Red Blood Cells (RBCs) swell and decrease the path length absorption coefficient. Decreasing absorption coefficient increases the transmission of light through the whole blood. The system was tested with a constructed optical cell that held whole blood in a capillary tube. As expected the light transmitted to the photodiode increases with decreasing glucose concentration. The average response time of the system was between 30-40 seconds.

  10. Gastrointestinal passage of [125I]Na and blood clearance of 125I-labelled bacteria recorded with a simple non-invasive technique

    International Nuclear Information System (INIS)

    Sundqvist, T.; Skogh, T.

    1982-01-01

    To measure blood concentrations of radiolabelled particles or substances, blood sampling is generally required. The kinetics of radioactivity variations in the blood can be studied by blood sampling from each individual or experimental animal. Alternatively blood samples can be taken from different individuals at different time points. With either of these methods it is difficult to predict the optimal time points for blood sampling, and important information can easily be missed, especially in rapid processes. In this study a simple non-invasive technique for continuous recording of blood radioactivity concentrations in mice is presented. (Auth.)

  11. Non-invasive techniques for the measurement of extraction fraction and permeability surface area product of 99Tcm DTPA in the human forearm

    International Nuclear Information System (INIS)

    Bell, S.D.; Peters, A.M.; Myers, M.J.

    1992-01-01

    Only a very limited number of clinical studies have been reported on the measurement of endothelial permeability to hydrophilic solutes (molecular weight 99 Tc m DTPA, are perfusion-dependent as well as diffusion-dependent. The authors describe non-invasive techniques for measurement of clearance and extraction fraction of 99 Tc m DTPA into the extravascular space of the resting forearm using a scintillation probe, from which we then calculated permeability surface area (PS) product. Their values for extraction fraction of about 0.5 and for PS product of about 3 ml per minute per 100 ml tissue are comparable to values reported in the literature for resting skeletal muscle using more invasive techniques. (author)

  12. Bioluminescence : the potential of a non-invasive bio-optical imaging technique and improvement of animal research

    NARCIS (Netherlands)

    Hesselink, J. W.; van Dam, G. M.

    2007-01-01

    Bioluminescence is an optical imaging technique that exploits the emission of photons at specific wavelengths based on energy-dependent reactions catalysed by luciferases. The technique makes it possible to monitor measure, and track biological processes in living animals. A short review is

  13. Note: A non-invasive electronic measurement technique to measure the embedded four resistive elements in a Wheatstone bridge sensor

    Energy Technology Data Exchange (ETDEWEB)

    Ravelo Arias, S. I.; Ramírez Muñoz, D. [Department of Electronic Engineering, University of Valencia, Avda. de la Universitat, s/n, 46100-Burjassot (Spain); Cardoso, S. [INESC Microsystems and Nanotechnologies (INESC-MN) and Institute for Nanosciences and Nanotechnologies, R. Alves Redol 9, Lisbon 1000-029 (Portugal); Ferreira, R. [INL-International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga, Braga 4715-31 (Portugal); Freitas, P. [INESC Microsystems and Nanotechnologies (INESC-MN) and Institute for Nanosciences and Nanotechnologies, R. Alves Redol 9, Lisbon 1000-029 (Portugal); INL-International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga, Braga 4715-31 (Portugal)

    2015-06-15

    The work shows a measurement technique to obtain the correct value of the four elements in a resistive Wheatstone bridge without the need to separate the physical connections existing between them. Two electronic solutions are presented, based on a source-and-measure unit and using discrete electronic components. The proposed technique brings the possibility to know the mismatching or the tolerance between the bridge resistive elements and then to pass or reject it in terms of its related common-mode rejection. Experimental results were taken in various Wheatstone resistive bridges (discrete and magnetoresistive integrated bridges) validating the proposed measurement technique specially when the bridge is micro-fabricated and there is no physical way to separate one resistive element from the others.

  14. Note: A non-invasive electronic measurement technique to measure the embedded four resistive elements in a Wheatstone bridge sensor

    International Nuclear Information System (INIS)

    Ravelo Arias, S. I.; Ramírez Muñoz, D.; Cardoso, S.; Ferreira, R.; Freitas, P.

    2015-01-01

    The work shows a measurement technique to obtain the correct value of the four elements in a resistive Wheatstone bridge without the need to separate the physical connections existing between them. Two electronic solutions are presented, based on a source-and-measure unit and using discrete electronic components. The proposed technique brings the possibility to know the mismatching or the tolerance between the bridge resistive elements and then to pass or reject it in terms of its related common-mode rejection. Experimental results were taken in various Wheatstone resistive bridges (discrete and magnetoresistive integrated bridges) validating the proposed measurement technique specially when the bridge is micro-fabricated and there is no physical way to separate one resistive element from the others

  15. Benthic O-2 uptake of two cold-water coral communities estimated with the non-invasive eddy correlation technique

    DEFF Research Database (Denmark)

    Rovelli, Lorenzo; Attard, Karl M.; Bryant, Lee D.

    2015-01-01

    , was a channel-like sound in Northern Norway at a depth of 220 m. Both sites were characterized by the presence of live mounds of the reef framework-forming scleractinian Lophelia pertusa and reef-associated fauna such as sponges, crustaceans and other corals. The measured O-2 uptake at the 2 sites varied...... times higher than the global mean for soft sediment communities at comparable depths. The measurements document the importance of CWC communities for local and regional carbon cycling and demonstrate that the EC technique is a valuable tool for assessing rates of benthic O2 uptake in such complex...

  16. The ventricular function after operative correction of chronic mitral insufficiency. Non-invasive study with technetium-99m pertechnetate. First passage technique

    International Nuclear Information System (INIS)

    Bougioukas, G.

    1982-01-01

    14 patients (age 49.6 ± 13.3 years) with pure mitral insufficiency of the second to fourth degree underwent an operative intervention on the mitral valve, whereby in 12 cases the valve was replaced and two times the insufficiency could be cleared up with a plastic reconstruction. On the average of 21.6 ± 11 months after the operation a non-invasive study was done with the help of heart scintigraphy 'first passage technique' with Tc 99m pertechnetate at rest and at maximum ergometeric stress. With this method pre- and postoperative end-diastolic volumes (227/ 114 ml), end-systolic volumes (69/ 46 ml), heart minute volumes (4.5/ 5.7 l/min), total output fraction of the left ventricle (61/ 69%), diastolic filling speed and emptying speed of the ventricle were determined as well as the measuring of the lung flow time. The speed of the rapid filling phase gave no indication of a hindrance as a result of an implanted valve or a plastic reconstruction. The changes under stress indicate a normal reaction of the ventricle. This ability to react corresponds clinically to the improvement of the patients on the average of 1.1 degrees according to the NYHA classification. (orig./TRV) [de

  17. A Comparative Evaluation of the Effect of Bonding Agent on the Tensile Bond Strength of Two Pit and Fissure Sealants Using Invasive and Non-invasive Techniques: An in-vitro Study.

    Science.gov (United States)

    Singh, Shamsher; Adlakha, Vivek; Babaji, Prashant; Chandna, Preetika; Thomas, Abi M; Chopra, Saroj

    2013-10-01

    Newer technologies and the development of pit and fissure sealants have shifted the treatment philosophy from 'drill and fill' to that of 'seal and heal'. The purpose of this in-vitro study was to evaluate the effects of bonding agents on the tensile bond strengths of two pit and fissure sealants by using invasive and non-invasive techniques. One hundred and twenty bicuspids were collected and teeth were divided into two groups: Group-I (Clinpro) and Group-II (Conseal f) with 60 teeth in each group. For evaluating tensile bond strengths, occlusal surfaces of all the teeth were flattened by reducing buccal and lingual cusps without disturbing fissures. Standardised polyvinyl tube was bonded to occlusal surfaces with respective materials. Sealants were applied, with or without bonding agents, in increments and they were light cured. Tensile bond strengths were determined by using Universal Testing Machine. Data were then statistically analysed by using Student t-test for comparison. A statistically significant difference was found in tensile bond strength in invasive with bonding agent group than in non-invasive with bonding agent group. This study revealed that invasive techniques increase the tensile bond strengths of sealants as compared to non- invasive techniques and that the use of a bonding agent as an intermediate layer between the tooth and fissure sealant is beneficial for increasing the bond strength.

  18. Using a non-invasive technique in nutrition: synchrotron radiation infrared microspectroscopy spectroscopic characterization of oil seeds treated with different processing conditions on molecular spectral factors influencing nutrient delivery.

    Science.gov (United States)

    Zhang, Xuewei; Yu, Peiqiang

    2014-07-02

    Non-invasive techniques are a key to study nutrition and structure interaction. Fourier transform infrared microspectroscopy coupled with a synchrotron radiation source (SR-IMS) is a rapid, non-invasive, and non-destructive bioanalytical technique. To understand internal structure changes in relation to nutrient availability in oil seed processing is vital to find optimal processing conditions. The objective of this study was to use a synchrotron-based bioanalytical technique SR-IMS as a non-invasive and non-destructive tool to study the effects of heat-processing methods and oil seed canola type on modeled protein structure based on spectral data within intact tissue that were randomly selected and quantify the relationship between the modeled protein structure and protein nutrient supply to ruminants. The results showed that the moisture heat-related processing significantly changed (pprocessing by dry heating. The moisture heating increased (p0.05) in the protein spectral profile between the raw and dry-heated canola tissue and between yellow- and brown-type canola tissue. The results indicated that different heat processing methods have different impacts on the protein inherent structure. The protein intrinsic structure in canola seed tissue was more sensitive and more response to the moisture heating in comparison to the dry heating. These changes are expected to be related to the nutritive value. However, the current study is based on limited samples, and more large-scale studies are needed to confirm our findings.

  19. EDITORIAL: Integrated non-invasive sensing techniques and geophysical methods for the study and conservation of architectural, archaeological and artistic heritage Integrated non-invasive sensing techniques and geophysical methods for the study and conservation of architectural, archaeological and artistic heritage

    Science.gov (United States)

    Masini, N.; Soldovieri, F.

    2011-09-01

    In the last two decades, the use of non-invasive methods for the study and conservation of cultural heritage, from artefacts and historical sites to recent architectural structures, has gained increasing interest. This is due to several reasons: (i) the improvement of performance and information resolution of sensors and devices; (ii) the increasing availability of user-friendly data/image analysis, and processing software and routines; (iii) the ever greater awareness of archaeologists and conservators of the benefits of these technologies, in terms of reduction of costs, time and the risk associated with direct and destructive investigations of archaeological sites (excavation) and monuments (i.e. masonry coring). The choice of diagnostic strategy depends on the spatial and physical characteristics of the cultural objects or sites, the aim of the investigation (knowledge, conservation, restoration) and the issues to be addressed (monitoring, decay assessment, etc). This makes the set up and validation of ad hoc procedures based on data processing and post-processing methods necessary, generally developed to address issues in other fields of application. This methodological perspective based on an integrated and multi-scale approach characterizes the papers of this special issue, which is focused on integrated non-invasive sensing techniques and geophysical methods for the study and conservation of architectural, archaeological and artistic heritage. In particular, attention is given to the advanced application of the synthetic aperture radar (SAR) from the satellite-based platform for deformation monitoring thanks to the innovative differential SAR interferometry (DInSAR) technique; Zeni et al show the significant possibilities of the proposed methodology in achieving a global vision not only of cultural heritage but also of the embedding territory. This collection also deals with the application of non-invasive diagnostics to archaeological prospecting, and

  20. NON-INVASIVE DETERMINATION OF THE LOCATION AND DISTRIBUTION OF FREE-PHASE DENSE NONAQUEOUS PHASE LIQUIDS (DNAPL) BY SEISMIC REFLECTION TECHNIQUES

    Energy Technology Data Exchange (ETDEWEB)

    Michael G. Waddell; William J. Domoracki; Tom J. Temples

    2001-12-01

    This annual technical progress report is for part of Task 4 (site evaluation), Task 5 (2D seismic design, acquisition, and processing), and Task 6 (2D seismic reflection, interpretation, and AVO analysis) on DOE contact number DE-AR26-98FT40369. The project had planned one additional deployment to another site other than Savannah River Site (SRS) or DOE Hanford Site. After the SUBCON midyear review in Albuquerque, NM, it was decided that two additional deployments would be performed. The first deployment is to test the feasibility of using non-invasive seismic reflection and AVO analysis as a monitoring tool to assist in determining the effectiveness of Dynamic Underground Stripping (DUS) in removal of DNAPL. The second deployment is to the Department of Defense (DOD) Charleston Naval Weapons Station Solid Waste Management Unit 12 (SWMU-12), Charleston, SC to further test the technique to detect high concentrations of DNAPL. The Charleston Naval Weapons Station SWMU-12 site was selected in consultation with National Energy Technology Laboratory (NETL) and DOD Naval Facilities Engineering Command Southern Division (NAVFAC) personnel. Based upon the review of existing data and due to the shallow target depth, the project team collected three Vertical Seismic Profiles (VSP) and an experimental P-wave seismic reflection line. After preliminary data analysis of the VSP data and the experimental reflection line data, it was decided to proceed with Task 5 and Task 6. Three high resolution P-wave reflection profiles were collected with two objectives; (1) design the reflection survey to image a target depth of 20 feet below land surface to assist in determining the geologic controls on the DNAPL plume geometry, and (2) apply AVO analysis to the seismic data to locate the zone of high concentration of DNAPL. Based upon the results of the data processing and interpretation of the seismic data, the project team was able to map the channel that is controlling the DNAPL plume

  1. Non-invasive hemoglobin monitoring.

    Science.gov (United States)

    Joseph, Bellal; Haider, Ansab; Rhee, Peter

    2016-09-01

    Technology has transformed the practice of medicine and surgery in particular over the last several decades. This change in practice has allowed diagnostic and therapeutic tests to be performed less invasively. Hemoglobin monitoring remains one of the most commonly performed diagnostic tests in the United States. Recently, non-invasive hemoglobin monitoring technology has gained popularity. The aim of this article is to review the principles of how this technology works, pros and cons, and the implications of non-invasive hemoglobin technology particularly in trauma surgery. Copyright © 2015 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  2. Are novel non-invasive imaging techniques needed in patients with suspected prosthetic heart valve endocarditis? A systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Habets, Jesse; Mali, Willem P.T.M. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Tanis, Wilco [Haga Teaching Hospital, Department of Cardiology, The Hague (Netherlands); Reitsma, Johannes B. [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); Brink, Renee B.A. van den [Academic Medical Center, Department of Cardiology, Amsterdam (Netherlands); Chamuleau, Steven A.J. [University Medical Center Utrecht, Department of Cardiology, Utrecht (Netherlands); Budde, Ricardo P.J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands)

    2015-07-15

    Multimodal non-invasive imaging plays a key role in establishing a diagnosis of PHV endocarditis. The objective of this study was to provide a systematic review of the literature and meta-analysis of the diagnostic accuracy of TTE, TEE, and MDCT in patients with (suspected) PHV endocarditis. Studies published between 1985 and 2013 were identified via search and cross-reference of PubMed/Embase databases. Studies were included if (1) they reported on the non-invasive index tests TTE, TEE, or MDCT; (2) data was provided on PHV endocarditis as the condition of interest; and (3) imaging results were verified against either surgical inspection/autopsy or clinical follow-up reference standards, thereby enabling the extraction of 2-by-2 tables. Twenty articles (including 496 patients) met the inclusion criteria for PHV endocarditis. TTE, TEE, and MDCT + TEE had a pooled sensitivity/specificity for vegetations of 29/100 %; 82/95 %, and 88/94 %, respectively. The pooled sensitivity/specificity of TTE, TEE, and MDCT + TEE for periannular complications was 36/93 %, 86/98 %, and 100/94 %, respectively. TEE showed good sensitivity and specificity for establishing a diagnosis of PHV endocarditis. Although MDCT data are limited, this review showed that MDCT in addition to TEE may improve sensitivity in detecting life-threatening periannular complications. (orig.)

  3. Are novel non-invasive imaging techniques needed in patients with suspected prosthetic heart valve endocarditis? A systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Habets, Jesse; Mali, Willem P.T.M.; Tanis, Wilco; Reitsma, Johannes B.; Brink, Renee B.A. van den; Chamuleau, Steven A.J.; Budde, Ricardo P.J.

    2015-01-01

    Multimodal non-invasive imaging plays a key role in establishing a diagnosis of PHV endocarditis. The objective of this study was to provide a systematic review of the literature and meta-analysis of the diagnostic accuracy of TTE, TEE, and MDCT in patients with (suspected) PHV endocarditis. Studies published between 1985 and 2013 were identified via search and cross-reference of PubMed/Embase databases. Studies were included if (1) they reported on the non-invasive index tests TTE, TEE, or MDCT; (2) data was provided on PHV endocarditis as the condition of interest; and (3) imaging results were verified against either surgical inspection/autopsy or clinical follow-up reference standards, thereby enabling the extraction of 2-by-2 tables. Twenty articles (including 496 patients) met the inclusion criteria for PHV endocarditis. TTE, TEE, and MDCT + TEE had a pooled sensitivity/specificity for vegetations of 29/100 %; 82/95 %, and 88/94 %, respectively. The pooled sensitivity/specificity of TTE, TEE, and MDCT + TEE for periannular complications was 36/93 %, 86/98 %, and 100/94 %, respectively. TEE showed good sensitivity and specificity for establishing a diagnosis of PHV endocarditis. Although MDCT data are limited, this review showed that MDCT in addition to TEE may improve sensitivity in detecting life-threatening periannular complications. (orig.)

  4. Effect of Injector Geometry on Atomization of a Liquid-Liquid Double Swirl Coaxial Injector Using Non-invasive Laser, Optical and X-ray Techniques

    Science.gov (United States)

    Radke, C. R.; Meyer, T. R.

    2014-01-01

    The spray characteristics of a liquid-liquid double swirl coaxial injector were studied using non-invasive optical, laser, and X-ray diagnostics. A parametric study of injector exit geometry demonstrated that spray breakup time, breakup type and sheet stability could be controlled with exit geometry. Phase Doppler interferometry was used to characterize droplet statistics and non-dimensional droplet parameters over a range of inlet conditions and for various fluids allowing for a study on the role of specific fluid properties in atomization. Further, X-ray radiography allowed for investigation of sheet thickness and breakup length to be quantified for different recess exit diameters and inlet pressures. Finally, computed tomography scans revealed that the spray cone was distinctively non-uniform and comprised of several pockets of increased mass flux.

  5. Formulation and in Vivo Evaluation for Anti-Aging Effects of an Emulsion Containing Basil Extract Using non- Invasive Biophysical Techniques

    Directory of Open Access Journals (Sweden)

    N. Akhtar

    2011-12-01

    Full Text Available Background and the purpose of study: Skin aging is a complex process induced by constant exposure to ultraviolet (UV irradiation and damages human skin. UV generates reactive oxygen species leading to collagen deficiency and eventually skin wrinkling. Basil contains a number of phenolics and favonoids which possess antioxidant properties. The aim of this study was to formulate and investigate the antiaging potential of a cream containing Basil extract. Methods: A single blinded study was conducted using non-invasive methods. Formulation containing 3% of the concentrated extract of Basil was developed by entrapping in the inner aqueous phase of w/o emulsion and base contained no extract. Both creams were stored at different storage conditions of 8°C, 25°C, 40°C and 40°C+ 75% relative humidity to predict their stabilities. The formulation and base were evaluated for their effects on various skin parameters i.e., moisture and trans epidermal water loss (TEWL, volume, energy and surface evaluation of the living skin (SELS. Results: Significant effects (p≤0.05 were observed for both creams in the case of TEWL. The base showed insignificant (p≤0.05 while formulation showed significant effects on skin moisture. Volume, SELS SEr (skin roughness, SEsc (skin scaliness, SEsm (skin smoothness, SEw (skin wrinkles parameter showed significant decline while texture parameter of ‘Energy' showed significant increase. Conclusion: The results statistically indicated that the active formulation containg extract of Basil exert antiaging effects when applied topically.

  6. Non-invasive neural stimulation

    Science.gov (United States)

    Tyler, William J.; Sanguinetti, Joseph L.; Fini, Maria; Hool, Nicholas

    2017-05-01

    Neurotechnologies for non-invasively interfacing with neural circuits have been evolving from those capable of sensing neural activity to those capable of restoring and enhancing human brain function. Generally referred to as non-invasive neural stimulation (NINS) methods, these neuromodulation approaches rely on electrical, magnetic, photonic, and acoustic or ultrasonic energy to influence nervous system activity, brain function, and behavior. Evidence that has been surmounting for decades shows that advanced neural engineering of NINS technologies will indeed transform the way humans treat diseases, interact with information, communicate, and learn. The physics underlying the ability of various NINS methods to modulate nervous system activity can be quite different from one another depending on the energy modality used as we briefly discuss. For members of commercial and defense industry sectors that have not traditionally engaged in neuroscience research and development, the science, engineering and technology required to advance NINS methods beyond the state-of-the-art presents tremendous opportunities. Within the past few years alone there have been large increases in global investments made by federal agencies, foundations, private investors and multinational corporations to develop advanced applications of NINS technologies. Driven by these efforts NINS methods and devices have recently been introduced to mass markets via the consumer electronics industry. Further, NINS continues to be explored in a growing number of defense applications focused on enhancing human dimensions. The present paper provides a brief introduction to the field of non-invasive neural stimulation by highlighting some of the more common methods in use or under current development today.

  7. NON-INVASIVE DETERMINATION OF THE LOCATION AND DISTRIBUTION OF FREE-PHASE DENSE NONAQUEOUS PHASE LIQUIDS (DNAPL) BY SEISMIC REFLECTION TECHNIQUES

    Energy Technology Data Exchange (ETDEWEB)

    Michael G. Waddell; William J. Domoracki; Tom J. Temples

    2001-05-01

    This semi-annual technical progress report is for Task 4 site evaluation, Task 5 seismic reflection design and acquisition, and Task 6 seismic reflection processing and interpretation on DOE contact number DE-AR26-98FT40369. The project had planned one additional deployment to another site other than Savannah River Site (SRS) or DOE Hanford. During this reporting period the project had an ASME peer review. The findings and recommendation of the review panel, as well at the project team response to comments, are in Appendix A. After the SUBCON midyear review in Albuquerque, NM and the peer review it was decided that two additional deployments would be performed. The first deployment is to test the feasibility of using non-invasive seismic reflection and AVO analysis as monitoring to assist in determining the effectiveness of Dynamic Underground Stripping (DUS) in removal of DNAPL. Under the rescope of the project, Task 4 would be performed at the Charleston Navy Weapons Station, Charleston, SC and not at the Dynamic Underground Stripping (DUS) project at SRS. The project team had already completed Task 4 at the M-area seepage basin, only a few hundred yards away from the DUS site. Because the geology is the same, Task 4 was not necessary. However, a Vertical Seismic Profile (VSP) was conducted in one well to calibrate the geology to the seismic data. The first deployment to the DUS Site (Tasks 5 and 6) has been completed. Once the steam has been turned off these tasks will be performed again to compare the results to the pre-steam data. The results from the first deployment to the DUS site indicated a seismic amplitude anomaly at the location and depths of the known high concentrations of DNAPL. The deployment to another site with different geologic conditions was supposed to occur during this reporting period. The first site selected was DOE Paducah, Kentucky. After almost eight months of negotiation, site access was denied requiring the selection of another site

  8. Non-invasive assessment of gastric activity

    International Nuclear Information System (INIS)

    Smallwood, R.H.; Brown, B.H.

    1983-01-01

    There have been many suggestions for the routine clinical use of the electro-enterogram, but with the exception of the reported usage in the USSR no significant penetration into medical practice has been reported elsewhere. Amongst the many suggestions have been the possible application of electrical stimulation via surface electrodes to overcome post-operative inhibition of intestinal electrical activity, which can be recorded via surface electrodes. Gastric emptying studies have shown that duodenal ulceration is associated with changes in the rate and pattern of emptying of solid meals. Identifiable patterns in the electro-gastrogram following a metal might have diagnostic application. There is some evidence of correlations of electrical activity and pathology in the large intestine. In the colon diverticular disease has been shown to change the frequency content of the slow wave electrical activity and there is some evidence that this might be recorded from surface electrodes. A major obstacle to progress remains the inability to relate non-invasive recordings to intestinal motility. The best hope may be the use of direct and yet non-invasive methods of obtaining motility and in this context real-time ultrasound imaging is probably the most promising technique. The electro-gastrogram has certainly been shown to allow recording of gastric slow wave activity and there is a reasonable hope that further methods of analysis will allow inferential information on motility to be obtained. The following section makes brief mention of these techniques

  9. Rapid MRI using a modified Dixon technique: a non-invasive and effective method for detection and monitoring of fatty metamorphosis of the liver

    International Nuclear Information System (INIS)

    Fishbein, M.H.; Stevens, W.R.

    2001-01-01

    Fatty liver and non-alcoholic steatohepatitis are frequently associated with obesity. Weight loss is the mainstay of therapy for these conditions. In this case report, we used a modification of the Dixon method to demonstrate normalization of hepatic fat content in an obese individual with fatty liver following weight reduction. This technique involves fast gradient echo instead of spin echo, which has been utilized previously, as the former provides an accurate and more rapid means of assessing hepatic fat content. This technique is recommended for the assessment of hepatic steatosis in at-risk subjects. (orig.)

  10. Rapid MRI using a modified Dixon technique: a non-invasive and effective method for detection and monitoring of fatty metamorphosis of the liver

    Energy Technology Data Exchange (ETDEWEB)

    Fishbein, M.H. [Pediatric Gastroenterology, Dept. of Pediatrics, Springfield, IL (United States); Stevens, W.R. [St. John' s Hospital, Department of Radiology, Springfield, IL (United States)

    2001-11-01

    Fatty liver and non-alcoholic steatohepatitis are frequently associated with obesity. Weight loss is the mainstay of therapy for these conditions. In this case report, we used a modification of the Dixon method to demonstrate normalization of hepatic fat content in an obese individual with fatty liver following weight reduction. This technique involves fast gradient echo instead of spin echo, which has been utilized previously, as the former provides an accurate and more rapid means of assessing hepatic fat content. This technique is recommended for the assessment of hepatic steatosis in at-risk subjects. (orig.)

  11. Imaging the pancreas: from ex vivo to non-invasive technology

    DEFF Research Database (Denmark)

    Holmberg, D; Ahlgren, U

    2008-01-01

    While many recently published reviews have covered non-invasive nuclear imaging techniques, the aim of this review is to focus on current developments in optical imaging technologies for investigating the pancreas. Several of these modalities are being developed into non-invasive, real-time monit......While many recently published reviews have covered non-invasive nuclear imaging techniques, the aim of this review is to focus on current developments in optical imaging technologies for investigating the pancreas. Several of these modalities are being developed into non-invasive, real...

  12. In-situ fluorimetry: A powerful non-invasive diagnostic technique for natural dyes used in artefacts. Part II. Identification of orcein and indigo in Renaissance tapestries

    Science.gov (United States)

    Clementi, C.; Miliani, C.; Romani, A.; Santamaria, U.; Morresi, F.; Mlynarska, K.; Favaro, G.

    2009-01-01

    In this paper, three Renaissance tapestries depicting scenes painted by Raffaello Sanzio, conserved at the Vatican Museum, were investigated using in-situ UV-Visible fluorimetric measurements. The results show that this technique is suitable for the detection of natural organic colorants used for dyeing the threads woven in these tapestries. The emission signals detected on red-purple colours were assigned to the colorant orcein and those on different nuances of blue and green colours to indigo by comparison with data from reference laboratory samples. The assignments were supported by chromatographic experiments carried out on threads taken from the back side of the tapestry in the same points analysed by spectrofluorimentry.

  13. Recent progress in methods for non-invasive measurements of local strain in practical superconducting wires and conductors using quantum beam techniques

    International Nuclear Information System (INIS)

    Osamura, Kozo; Machiya, Shutaro; Tsuchiya, Yoshinori; Suzuki, Hiroshi; Awaji, Satoshi; Takahashi, Kohki; Oguro, Hidetoshi; Harjo, Stefanus; Hemmi, Tsutomu; Nakamoto, Tatsushi; Sugano, Michinaka; Jin, Xinzhe; Kajiwara, Kentaro

    2014-01-01

    Practical superconducting wires are designed with a composite structure to meet the desired engineering characteristics by expert selection of materials and design of the architecture. In practice, the local strain exerted on the superconducting component influences the electromagnetic properties. Here, recent progress in methods used to measure the local strain in practical superconducting wires and conductors using quantum beam techniques is introduced. Recent topics on the strain dependence of critical current are reviewed for three major practical wires: ITER-Nb 3 Sn strand, DI-BSCCO wires and REBCO tapes. (author)

  14. Office hysteroscopic-guided selective tubal chromopertubation: acceptability, feasibility and diagnostic accuracy of this new diagnostic non-invasive technique in infertile women.

    Science.gov (United States)

    Carta, Gaspare; Palermo, Patrizia; Pasquale, Chiara; Conte, Valeria; Pulcinella, Ruggero; Necozione, Stefano; Cofini, Vincenza; Patacchiola, Felice

    2018-06-01

    The aim of this study was to evaluate accuracy, tolerability and side effects of office hysteroscopic-guided chromoperturbations in infertile women without anaesthesia. Forty-nine infertile women underwent the procedure to evaluate tubal patency and the uterine cavity. Women with unilateral or bilateral tubal stenosis at hysteroscopy with chromoperturbation, and women with bilateral tubal patency who did not conceive during the period of six months, underwent laparoscopy with chromoperturbation. The results obtained from hysteroscopy and laparoscopy in the assessment of tubal patency were compared. Sensitivity, specificity, accuracy, positive-predictive value and negative-predictive value were used to describe diagnostic performance. Pain and tolerance were assessed during procedure using a visual analogue scale (VAS). Side effects or late complications and pregnancy rate were also recorded three and six months after the procedure. The specificity was 87.8% (95% CI: 73.80-95.90), sensitivity was 85.7% (95% CI 57.20-98.20), positive and negative predictive values were 70.6% (95% CI: 44.00-89) and 94.7% (95% CI: 82.30-99.40), respectively. Pregnancy rate (PR) within six months after performance of hysteroscopy with chromoperturbation was 27%. Office hysteroscopy-guided selective chromoperturbation in infertile patients is a valid technique to evaluate tubal patency and uterine cavity.

  15. NON-INVASIVE DETERMINATION OF THE LOCATION AND DISTRIBUTION OF FREE-PHASE DENSE NONAQUEOUS PHASE LIQUIDS (DNAPL) BY SEISMIC REFLECTION TECHNIQUES

    International Nuclear Information System (INIS)

    Michael G. Waddell; William J. Domoracki; Tom J. Temples; Jerome Eyer

    2001-01-01

    The Earth Sciences and Resources Institute, University of South Carolina is conducting a 14 month proof of concept study to determine the location and distribution of subsurface Dense Nonaqueous Phase Liquid (DNAPL) carbon tetrachloride (CCl 4 ) contamination at the 216-Z-9 crib, 200 West area, Department of Energy (DOE) Hanford Site, Washington by use of two-dimensional high resolution seismic reflection surveys and borehole geophysical data. The study makes use of recent advances in seismic reflection amplitude versus offset (AVO) technology to directly detect the presence of subsurface DNAPL. The techniques proposed are a noninvasive means towards site characterization and direct free-phase DNAPL detection. This report covers the results of Task 3 and change of scope of Tasks 4-6. Task 1 contains site evaluation and seismic modeling studies. The site evaluation consists of identifying and collecting preexisting geological and geophysical information regarding subsurface structure and the presence and quantity of DNAPL. The seismic modeling studies were undertaken to determine the likelihood that an AVO response exists and its probable manifestation. Task 2 is the design and acquisition of 2-D seismic reflection data designed to image areas of probable high concentration of DNAPL. Task 3 is the processing and interpretation of the 2-D data. Task 4, 5, and 6 were designing, acquiring, processing, and interpretation of a three dimensional seismic survey (3D) at the Z-9 crib area at 200 west area, Hanford

  16. NON-INVASIVE DETERMINATION OF THE LOCATION AND DISTRBUTION OF FREE-PHASE DENSE NONAQUEOUS PHASE LIQUIDS (DNAPL) BY SEISMIC REFLECTION TECHNIQUES

    Energy Technology Data Exchange (ETDEWEB)

    Michael G. Waddell; William J. Domoracki; Jerome Eyer

    2003-01-01

    The Earth Sciences and Resources Institute, University of South Carolina is conducting a proof of concept study to determine the location and distribution of subsurface DNAPL carbon tetrachloride (CCl{sub 4}) contamination at the 216-Z-9 crib, 200 West area, DOE Hanford Site, Washington by use of two-dimensional high-resolution seismic reflection surveys and borehole geophysical data. The study makes use of recent advances in seismic reflection amplitude versus offset (AVO) technology to directly detect the presence of subsurface DNAPL. The techniques proposed are noninvasive means of site characterization and direct free-phase DNAPL detection. This final report covers the results of Tasks 1, 2, and 3. Task (1) contains site evaluation and seismic modeling studies. The site evaluation consists of identifying and collecting preexisting geological and geophysical information regarding subsurface structure and the presence and quantity of DNAPL. The seismic modeling studies were undertaken to determine the likelihood that an AVO response exists and its probable manifestation. Task (2) is the design and acquisition of 2-D seismic reflection data to image areas of probable high concentration of DNAPL. Task (3) is the processing and interpretation of the 2-D data. During the commission of these tasks four seismic reflection profiles were collected. Subsurface velocity information was obtained by vertical seismic profile surveys in three wells. The interpretation of these data is in two parts. Part one is the construction and interpretation of structural contour maps of the contact between the Hanford Fine unit and the underlying Plio/Pleistocene unit and of the contact between the Plio/Pleistocene unit and the underlying caliche layer. These two contacts were determined to be the most likely surfaces to contain the highest concentration CCl{sub 4}. Part two of the interpretation uses the results of the AVO modeling to locate any seismic amplitude anomalies that might be

  17. NON-INVASIVE DETERMINATION OF THE LOCATION AND DISTRBUTION OF FREE-PHASE DENSE NONAQUEOUS PHASE LIQUIDS (DNAPL) BY SEISMIC REFLECTION TECHNIQUES

    International Nuclear Information System (INIS)

    Waddell, Michael G.; Domoracki, William J.; Eyer, Jerome

    2003-01-01

    The Earth Sciences and Resources Institute, University of South Carolina is conducting a proof of concept study to determine the location and distribution of subsurface DNAPL carbon tetrachloride (CCl 4 ) contamination at the 216-Z-9 crib, 200 West area, DOE Hanford Site, Washington by use of two-dimensional high-resolution seismic reflection surveys and borehole geophysical data. The study makes use of recent advances in seismic reflection amplitude versus offset (AVO) technology to directly detect the presence of subsurface DNAPL. The techniques proposed are noninvasive means of site characterization and direct free-phase DNAPL detection. This final report covers the results of Tasks 1, 2, and 3. Task (1) contains site evaluation and seismic modeling studies. The site evaluation consists of identifying and collecting preexisting geological and geophysical information regarding subsurface structure and the presence and quantity of DNAPL. The seismic modeling studies were undertaken to determine the likelihood that an AVO response exists and its probable manifestation. Task (2) is the design and acquisition of 2-D seismic reflection data to image areas of probable high concentration of DNAPL. Task (3) is the processing and interpretation of the 2-D data. During the commission of these tasks four seismic reflection profiles were collected. Subsurface velocity information was obtained by vertical seismic profile surveys in three wells. The interpretation of these data is in two parts. Part one is the construction and interpretation of structural contour maps of the contact between the Hanford Fine unit and the underlying Plio/Pleistocene unit and of the contact between the Plio/Pleistocene unit and the underlying caliche layer. These two contacts were determined to be the most likely surfaces to contain the highest concentration CCl 4 . Part two of the interpretation uses the results of the AVO modeling to locate any seismic amplitude anomalies that might be

  18. Effects of non-invasive neurostimulation on craving: a meta-analysis

    NARCIS (Netherlands)

    Jansen, Jochem M.; Daams, Joost G.; Koeter, Maarten W. J.; Veltman, Dick J.; van den Brink, Wim; Goudriaan, Anna E.

    2013-01-01

    This meta-analysis was conducted to evaluate the available evidence regarding the effects of non-invasive neurostimulation of the dorsolateral prefrontal cortex (DLPFC), on craving in substance dependence and craving for high palatable food. Non-invasive neurostimulation techniques were restricted

  19. Effects of non-invasive neurostimulation on craving: A meta-analysis

    NARCIS (Netherlands)

    Jansen, J.M.; Daams, J.G.; Koeter, M.W.; Veltman, D.J.; van den Brink, W.; Goudriaan, A.E.

    2013-01-01

    This meta-analysis was conducted to evaluate the available evidence regarding the effects of non-invasive neurostimulation of the dorsolateral prefrontal cortex (DLPFC), on craving in substance dependence and craving for high palatable food. Non-invasive neurostimulation techniques were restricted

  20. Skin Rejuvenation with Non-Invasive Pulsed Electric Fields

    Science.gov (United States)

    Golberg, Alexander; Khan, Saiqa; Belov, Vasily; Quinn, Kyle P.; Albadawi, Hassan; Felix Broelsch, G.; Watkins, Michael T.; Georgakoudi, Irene; Papisov, Mikhail; Mihm, Martin C., Jr.; Austen, William G., Jr.; Yarmush, Martin L.

    2015-05-01

    Degenerative skin diseases affect one third of individuals over the age of sixty. Current therapies use various physical and chemical methods to rejuvenate skin; but since the therapies affect many tissue components including cells and extracellular matrix, they may also induce significant side effects, such as scarring. Here we report on a new, non-invasive, non-thermal technique to rejuvenate skin with pulsed electric fields. The fields destroy cells while simultaneously completely preserving the extracellular matrix architecture and releasing multiple growth factors locally that induce new cells and tissue growth. We have identified the specific pulsed electric field parameters in rats that lead to prominent proliferation of the epidermis, formation of microvasculature, and secretion of new collagen at treated areas without scarring. Our results suggest that pulsed electric fields can improve skin function and thus can potentially serve as a novel non-invasive skin therapy for multiple degenerative skin diseases.

  1. Skin Rejuvenation with Non-Invasive Pulsed Electric Fields

    Science.gov (United States)

    Golberg, Alexander; Khan, Saiqa; Belov, Vasily; Quinn, Kyle P.; Albadawi, Hassan; Felix Broelsch, G.; Watkins, Michael T.; Georgakoudi, Irene; Papisov, Mikhail; Mihm Jr., Martin C.; Austen Jr., William G.; Yarmush, Martin L.

    2015-01-01

    Degenerative skin diseases affect one third of individuals over the age of sixty. Current therapies use various physical and chemical methods to rejuvenate skin; but since the therapies affect many tissue components including cells and extracellular matrix, they may also induce significant side effects, such as scarring. Here we report on a new, non-invasive, non-thermal technique to rejuvenate skin with pulsed electric fields. The fields destroy cells while simultaneously completely preserving the extracellular matrix architecture and releasing multiple growth factors locally that induce new cells and tissue growth. We have identified the specific pulsed electric field parameters in rats that lead to prominent proliferation of the epidermis, formation of microvasculature, and secretion of new collagen at treated areas without scarring. Our results suggest that pulsed electric fields can improve skin function and thus can potentially serve as a novel non-invasive skin therapy for multiple degenerative skin diseases. PMID:25965851

  2. Non-invasive acoustic-based monitoring of uranium in solution and H/D ratio

    Energy Technology Data Exchange (ETDEWEB)

    Pantea, Cristian [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Beedle, Christopher Craig [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sinha, Dipen N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lakis, Rollin Evan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-01

    The primary objective of this project is to adapt existing non-invasive acoustic techniques (Swept-Frequency Acoustic Interferometry and Gaussian-pulse acoustic technique) for the purpose of demonstrating the ability to quantify U or H/D ratios in solution. Furthermore, a successful demonstration will provide an easily implemented, low cost, and non-invasive method for remote and unattended uranium mass measurements for International Atomic Energy Agency (IAEA).

  3. [Meta-analyses on measurement precision of non-invasive hemodynamic monitoring technologies in adults].

    Science.gov (United States)

    Pestel, G; Fukui, K; Higashi, M; Schmidtmann, I; Werner, C

    2018-06-01

    An ideal non-invasive monitoring system should provide accurate and reproducible measurements of clinically relevant variables that enables clinicians to guide therapy accordingly. The monitor should be rapid, easy to use, readily available at the bedside, operator-independent, cost-effective and should have a minimal risk and side effect profile for patients. An example is the introduction of pulse oximetry, which has become established for non-invasive monitoring of oxygenation worldwide. A corresponding non-invasive monitoring of hemodynamics and perfusion could optimize the anesthesiological treatment to the needs in individual cases. In recent years several non-invasive technologies to monitor hemodynamics in the perioperative setting have been introduced: suprasternal Doppler ultrasound, modified windkessel function, pulse wave transit time, radial artery tonometry, thoracic bioimpedance, endotracheal bioimpedance, bioreactance, and partial CO 2 rebreathing have been tested for monitoring cardiac output or stroke volume. The photoelectric finger blood volume clamp technique and respiratory variation of the plethysmography curve have been assessed for monitoring fluid responsiveness. In this manuscript meta-analyses of non-invasive monitoring technologies were performed when non-invasive monitoring technology and reference technology were comparable. The primary evaluation criterion for all studies screened was a Bland-Altman analysis. Experimental and pediatric studies were excluded, as were all studies without a non-invasive monitoring technique or studies without evaluation of cardiac output/stroke volume or fluid responsiveness. Most studies found an acceptable bias with wide limits of agreement. Thus, most non-invasive hemodynamic monitoring technologies cannot be considered to be equivalent to the respective reference method. Studies testing the impact of non-invasive hemodynamic monitoring technologies as a trend evaluation on outcome, as well as

  4. Visualisation of axolotl blastema cells and pig endothelial progenitor cells using very small super paramagnetic iron oxide particles in MRI: A technique with applications for non invasive visualisation of regenerative processes

    DEFF Research Database (Denmark)

    Lauridsen, Henrik; Kjær, N.B.; Bek, Maria

    oxide particles (VSOP) in animal cells enable non invasive cell tracking using magnetic resonance imaging (MRI) and can prove useful, when visualising regenerative processes. This study examines the possibility of labelling limited numbers of axolotl blastema cells (aBC) and pig endothelial progenitor...... implanted in live axolotl tail and dead porcine heart, respectively. Cellular iron uptake was determined using inductively coupled plasma optical emission spectrometry (ICP-OES). Results: T2*-weighted 2D gradient-echo sequences on samples of 10˄5 cells yielded at significant linear correlations between...

  5. [Non-invasive assessment of fatty liver].

    Science.gov (United States)

    Egresi, Anna; Lengyel, Gabriella; Hagymási, Krisztina

    2015-04-05

    As the result of various harmful effects (infectious agents, metabolic diseases, unhealthy diet, obesity, toxic agents, autoimmune processes) hepatic damage may develop, which can progress towards liver steatosis, and fibrosis as well. The most common etiological factors of liver damages are hepatitis B and C infection, alcohol consumption and non-alcoholic fatty liver disease. Liver biopsy is considered as the gold standard for the diagnosis of chronic liver diseases. Due to the dangers and complications of liver biopsy, studies are focused on non-invasive markers and radiological imaging for liver steatosis, progression of fatty liver, activity of the necroinflammation and the severity of the fibrosis. Authors review the possibilities of non-invasive assessment of liver steatosis. The statistical features of the probes (positive, negative predictive values, sensitivity, specificity) are reviewed. The role of radiological imaging is also discussed. Although the non-invasive methods discussed in this article are useful to assess liver steatosis, further studies are needed to validate to follow progression of the diseases and to control therapeutic response.

  6. Emerging non-invasive Raman methods in process control and forensic applications.

    Science.gov (United States)

    Macleod, Neil A; Matousek, Pavel

    2008-10-01

    This article reviews emerging Raman techniques (Spatially Offset and Transmission Raman Spectroscopy) for non-invasive, sub-surface probing in process control and forensic applications. New capabilities offered by these methods are discussed and several application examples are given including the non-invasive detection of counterfeit drugs through blister packs and opaque plastic bottles and the rapid quantitative analysis of the bulk content of pharmaceutical tablets and capsules without sub-sampling.

  7. Non-invasive means of measuring hepatic fat content.

    Science.gov (United States)

    Mehta, Sanjeev-R; Thomas, E-Louise; Bell, Jimmy-D; Johnston, Desmond-G; Taylor-Robinson, Simon-D

    2008-06-14

    Hepatic steatosis affects 20% to 30% of the general adult population in the western world. Currently, the technique of choice for determining hepatic fat deposition and the stage of fibrosis is liver biopsy. However, it is an invasive procedure and its use is limited, particularly in children. It may also be subject to sampling error. Non-invasive techniques such as ultrasound, computerised tomography (CT), magnetic resonance imaging (MRI) and proton magnetic resonance spectroscopy ((1)H MRS) can detect hepatic steatosis, but currently cannot distinguish between simple steatosis and steatohepatitis, or stage the degree of fibrosis accurately. Ultrasound is widely used to detect hepatic steatosis, but its sensitivity is reduced in the morbidly obese and also in those with small amounts of fatty infiltration. It has been used to grade hepatic fat content, but this is subjective. CT can detect hepatic steatosis, but exposes subjects to ionising radiation, thus limiting its use in longitudinal studies and in children. Recently, magnetic resonance (MR) techniques using chemical shift imaging have provided a quantitative assessment of the degree of hepatic fatty infiltration, which correlates well with liver biopsy results in the same patients. Similarly, in vivo (1)H MRS is a fast, safe, non-invasive method for the quantification of intrahepatocellular lipid (IHCL) levels. Both techniques will be useful tools in future longitudinal clinical studies, either in examining the natural history of conditions causing hepatic steatosis (e.g. non-alcoholic fatty liver disease), or in testing new treatments for these conditions.

  8. The use of non-invasive fetal electrocardiography in diagnosing second-degree fetal atrioventricular block.

    Science.gov (United States)

    Lakhno, Igor; Behar, Joachim A; Oster, Julien; Shulgin, Vyacheslav; Ostras, Oleksii; Andreotti, Fernando

    2017-01-01

    Complete atrioventricular block in fetuses is known to be mostly associated with autoimmune disease and can be irreversible if no steroids treatment is provided. Conventional methods used in clinical practice for diagnosing fetal arrhythmia are limited since they do not reflect the primary electrophysiological conduction processes that take place in the myocardium. The non-invasive fetal electrocardiogram has the potential to better support fetal arrhythmias diagnosis through the continuous analysis of the beat to beat variation of the fetal heart rate and morphological analysis of the PQRST complex. We present two retrospective case reports on which atrioventricular block diagnosis could have been supported by the non-invasive fetal electrocardiogram. The two cases comprised a 22-year-old pregnant woman with the gestational age of 31 weeks and a 25-year-old pregnant woman with the gestational age of 41 weeks. Both women were admitted to the Department of Maternal and Fetal Medicine at the Kyiv and Kharkiv municipal perinatal clinics. Patients were observed using standard fetal monitoring methods as well as the non-invasive fetal electrocardiogram. The non-invasive fetal electrocardiographic recordings were analyzed retrospectively, where it is possible to identify the presence of the atrioventricular block. This study demonstrates, for the first time, the feasibility of the non-invasive fetal electrocardiogram as a supplementary method to diagnose of the fetal atrioventricular block. Combined with current fetal monitoring techniques, non-invasive fetal electrocardiography could support clinical decisions.

  9. Non-invasive assessment of the liver using imaging

    Science.gov (United States)

    Thorling Thompson, Camilla; Wang, Haolu; Liu, Xin; Liang, Xiaowen; Crawford, Darrell H.; Roberts, Michael S.

    2016-12-01

    Chronic liver disease causes 2,000 deaths in Australia per year and early diagnosis is crucial to avoid progression to cirrhosis and end stage liver disease. There is no ideal method to evaluate liver function. Blood tests and liver biopsies provide spot examinations and are unable to track changes in function quickly. Therefore better techniques are needed. Non-invasive imaging has the potential to extract increased information over a large sampling area, continuously tracking dynamic changes in liver function. This project aimed to study the ability of three imaging techniques, multiphoton and fluorescence lifetime imaging microscopy, infrared thermography and photoacoustic imaging, in measuring liver function. Collagen deposition was obvious in multiphoton and fluorescence lifetime imaging in fibrosis and cirrhosis and comparable to conventional histology. Infrared thermography revealed a significantly increased liver temperature in hepatocellular carcinoma. In addition, multiphoton and fluorescence lifetime imaging and photoacoustic imaging could both track uptake and excretion of indocyanine green in rat liver. These results prove that non-invasive imaging can extract crucial information about the liver continuously over time and has the potential to be translated into clinic in the assessment of liver disease.

  10. Use of Doppler ultrasound for non-invasive urodynamic diagnosis

    Directory of Open Access Journals (Sweden)

    Hideo Ozawa

    2009-01-01

    Full Text Available Objectives: A totally non-invasive transperineal urodynamic technique using Doppler ultrasonography has been developed. Methods: Since normal urine does not have blood cells, urine was thought not to produce the Doppler effects. However, basic studies confirmed that the decrease of pressure at high velocity (Bernouilli effect caused dissolved gas to form microbubbles, which are detected by Doppler ultrasonography. Subjects sat and the probe was advanced via remote control to achieve gentle contact with the perineal skin. The digital uroflow data signals and the color Doppler ultrasound video images were processed on a personal computer. The flow-velocity curves from two sites; the distal prostatic urethra just above the external sphincter (V1 and the sphincteric urethra (V2 were plotted against time. The parameters of both the pressure-flow studies and the Doppler ultrasound urodynamic studies were compared in men who had various degrees of obstruction. Results: Functional cross-sectional area at prostatic urethra (A1, calculated by Q max /V1, was lower in the group of bladder outlet obstruction (BOO vs. control group. Velocity ratio (VR, which was calculated by V1/V2, was the parameter having the best correlation with BOO index, though A1 had a similar correlation. This method is viable to diagnose the degree of BOO. Conclusions: The development of non-invasive Doppler ultrasound videourodynamics (Doppler UDS will dramatically expand the information on voiding function.

  11. Fecal Glucocorticoid Analysis: Non-invasive Adrenal Monitoring in Equids.

    Science.gov (United States)

    Yarnell, Kelly; Purcell, Rebecca S; Walker, Susan L

    2016-04-25

    Adrenal activity can be assessed in the equine species by analysis of feces for corticosterone metabolites. During a potentially aversive situation, corticotrophin releasing hormone (CRH) is released from the hypothalamus in the brain. This stimulates the release of adrenocorticotrophic hormone (ACTH) from the pituitary gland, which in turn stimulates release of glucocorticoids from the adrenal gland. In horses the glucocorticoid corticosterone is responsible for several adaptations needed to support equine flight behaviour and subsequent removal from the aversive situation. Corticosterone metabolites can be detected in the feces of horses and assessment offers a non-invasive option to evaluate long term patterns of adrenal activity. Fecal assessment offers advantages over other techniques that monitor adrenal activity including blood plasma and saliva analysis. The non-invasive nature of the method avoids sampling stress which can confound results. It also allows the opportunity for repeated sampling over time and is ideal for studies in free ranging horses. This protocol describes the enzyme linked immunoassay (EIA) used to assess feces for corticosterone, in addition to the associated biochemical validation.

  12. Non-invasive assessment of coronary calcification

    International Nuclear Information System (INIS)

    Vliegenthart, Rozemarijn; Oei, Hok-Hay S.; Hofman, Albert; Oudkerk, Matthijs; Witteman, Jackqueline C. M.

    2004-01-01

    Electron-beam tomography (EBT) and multi-detector computed tomography (MDCT) enable the noninvasive assessment of coronary calcification. The amount of coronary calcification, as detected by EBT, has a close relation with the amount of coronary atherosclerosis, which is the substrate for the occurrence of myocardial infarction and sudden cardiac death. Calcification of the coronary arteries can be seen as a cumulative measure of life-time exposure to cardiovascular risk factors. Several studies have shown that the amount of coronary calcification is associated with the risk of coronary heart disease. Therefore, coronary calcification is a promising method for non-invasive detection of asymptomatic subjects at high risk of developing coronary heart disease. Whether measurement of coronary calcification also increases the predictive power of coronary events based on cardiovascular risk factors is topic of current research

  13. NON-INVASIVE INVERSE PROBLEM IN CIVIL ENGINEERING

    Directory of Open Access Journals (Sweden)

    Jan Havelka

    2017-11-01

    Full Text Available In this contribution we focus on recovery of spatial distribution of material parameters utilizing only non-invasive boundary measurements. Such methods has gained its importance as imaging techniques in medicine, geophysics or archaeology. We apply similar principles for non-stationary heat transfer in civil engineering. In oppose to standard technique which rely on external loading devices, we assume the natural fluctuation of temperature throughout day and night can provide sufficient information to recover the underlying material parameters. The inverse problem was solved by a modified regularised Gauss-Newton iterative scheme and the underlying forward problem is solved with a finite element space-time discretisation. We show a successful reconstruction of material parameters on a synthetic example with real measurements. The virtual experiment also reveals the insensitivity to practical precision of sensor measurements.

  14. Non-invasive biological dosimetry of the skin

    International Nuclear Information System (INIS)

    Barton, S.; Marks, R.; Charles, M.W.; Wells, J.

    1986-01-01

    Investigations designed to identify a potential biological dosimetry technique to examine the effects of X-ray doses down to 0.1 Gy on human skin, are described. In a variety of parameters assessed, the most important changes observed were a significant depression in epidermal cell production in the basal layer after X-ray doses between 0.5 Gy and 1 Gy and a concomitant reduction in the desquamation rate of corneocytes after doses above 1 Gy. Changes in non-specific esterase (NSE) activity were also observed. Further work is described which applies these results to several non-invasive techniques which may have potential for routine application. Preliminary data from irradiated human skin are presented on the measurement of forced desquamation, the evaluation of NSE activity from hair samples and the evaluation of stratum corneum turnover time using the fluorescent dye, dansyl chloride. (author)

  15. Non-invasive Blood Glucose Quantification Using a Hybrid Sensor

    Directory of Open Access Journals (Sweden)

    Sundararajan JAYAPAL

    2009-02-01

    Full Text Available Diabetes Mellitus is a group of metabolic diseases characterized by high blood sugar (glucose levels which result from defects in insulin secretion. It is very important for the diabetics and normal people to have a correct blood glucose level. The HbA1c test is the most preferred test by renowned doctors for glucose quantification. But this test is an invasive one. At present, there are many available techniques for this purpose but these are mostly invasive or minimally non-invasive and most of these are under research. Among the different methods available, the photo acoustic (PA methods provide a reliable solution since the acoustical energy loss is much less compared to the optical or other techniques. Here a novel framework is presented for blood glucose level measurement using a combination of the HbA1c test and a PA method to get an absolutely consistent and precise, non-invasive technique. The setup uses a pulsed laser diode with pulse duration of 5-15 ns and at a repetition rate of 10 Hz as the source. The detector setup is based on the piezoelectric detection. It consists of a ring detector that includes two double ring sensors that are attached to the ring shaped module that can be worn around the finger. The major aim is to detect the photo acoustic signals from the glycated hemoglobin with the least possible error. The proposed monitoring system is designed with extreme consideration to precision and compatibility with the other computing devices. The results obtained in this research have been studied and analyzed by comparing these with those of in-vitro techniques like the HPLC. The comparison has been plotted and it shows a least error. The results also show a positive drive for using this concept as a basis for future extension in quantifying the other blood components.

  16. Non-invasive diagnostic methods in dentistry

    Science.gov (United States)

    Todea, Carmen

    2016-03-01

    The paper, will present the most important non-invasive methods for diagnostic, in different fields of dentistry. Moreover, the laser-based methods will be emphasis. In orthodontics, 3D laser scanners are increasingly being used to establish database for normative population and cross-sectional growth changes but also to asses clinical outcomes in orthognatic surgical and non-surgical treatments. In prevention the main methods for diagnostic of demineralization and caries detection in early stages are represented by laser fluorescence - Quantitative Light Florescence (QLF); DiagnoDent-system-655nm; FOTI-Fiberoptic transillumination; DIFOTI-Digital Imaging Fiberoptic transillumination; and Optical Coherence Tomography (OCT). In odontology, Laser Doppler Flowmetry (LDF) is a noninvasive real time method used for determining the tooth vitality by monitoring the pulp microcirculation in traumatized teeth, fractured teeth, and teeth undergoing different conservative treatments. In periodontology, recently study shows the ability of LDF to evaluate the health of gingival tissue in periodontal tissue diseases but also after different periodontal treatments.

  17. Applicability of Non-Invasive Sampling in Population Genetic Study of Taiwanese Macaques (Macaca cyclopis

    Directory of Open Access Journals (Sweden)

    Jui-Hua Chu

    2006-12-01

    Full Text Available This paper presents a pilot study conducted to test the applicability of non-invasive sampling approach in population genetic studies of Taiwanese macaques (Macaca cyclopis. Monkey feces were collected in the field and used as non-invasive DNA sources. PCR success rates of both microsatellite and mitochondrial DNA markers were examined. When compared with other studies by non-invasive genetic sampling of different mammal species, success rate of microsatellite PCR amplification is low (42.4%, N = 181 while that of mtDNA PCR amplification is acceptable (66.5%, N = 334. The low PCR success rate and poor PCR repeatability of microsatellite alleles due to allelic dropout and false alleles make it difficult to obtain a reliable microsatellite data set. However, the difficulties may be overcome by new techniques.

  18. Non-invasive physical treatments for chronic/recurrent headache

    NARCIS (Netherlands)

    Brønfort, Gert; Haas, Mitchell; Evans, Roni L.; Goldsmith, Charles H.; Assendelft, Willem J.J.; Bouter, Lex M.

    2014-01-01

    Background: Non-invasive physical treatments are often used to treat common types of chronic/recurrent headache. Objectives: To quantify and compare the magnitude of short- and long-term effects of non-invasive physical treatments for chronic/recurrent headaches. Search methods: We searched the

  19. Non-invasive physical treatments for chronic/recurrent headache.

    NARCIS (Netherlands)

    Bronfort, G.; Nilsson, N.; Haas, M.; Evans, R.; Goldsmith, C. H.; Assendelft, W. J.; Bouter, L. M.

    2004-01-01

    BACKGROUND: Non-invasive physical treatments are often used to treat common types of chronic/recurrent headache. OBJECTIVES: To quantify and compare the magnitude of short- and long-term effects of non-invasive physical treatments for chronic/recurrent headaches. SEARCH STRATEGY: We searched the

  20. Non invasive sensing technologies for cultural heritage management and fruition

    Science.gov (United States)

    Soldovieri, Francesco; Masini, Nicola

    2016-04-01

    monitoring of monuments and sites. In this way, we will be able to improve the appreciation of diagnostics and remote sensing technologies by the end-users. At the conference, we will show and discuss several study cases depicting the deployment of this knowledge chain in realistic conditions regarding the CH management. References Leucci G., Masini N., Persico R., Soldovieri F. 2011. GPR and sonic tomography for structural restoration: the case of the cathedral of Tricarico, Journal of Geophysics and Engineering, 8 (3), 76-92, doi:10.1088/1742-2132/8/3/S08 Masini N., Soldovieri F. 2011. Editorial: Integrated non-invasive sensing techniques and geophysical methods for the study and conservation of architectural, archaeological and artistic heritage, Journal of Geophysics and Engineering, 8 (3), 1-2, doi:10.1088/1742-2132/8/3/E01 Masini N., Persico R., Rizzo E., Calia A., Giannotta M.T., Quarta G., Pagliuca A. 2010, Integrated Techniques for Analysis and Monitoring of Historical Monuments: the case of S.Giovanni al Sepolcro in Brindisi (Southern Italy), Near Surface Geophysics, 8(5), 423-432, doi:10.3997/1873-0604.2010012

  1. Non-invasive imaging of kupffer cell status using radiolabelled mannosylated albumin

    NARCIS (Netherlands)

    Mahajan, V.; Hartimath, S.; Comley, R.; Stefan-Gueldner, M.; Roth, A.; Poelstra, K.; Reker-Smit, C.; Kamps, J.; Dierckx, R.; de Vries, Erik

    2014-01-01

    Background and Aims: Kupffer cells are responsible for maintaining liver homeostasis and have a vital role in chronic hepatotoxicity and various liver diseases. Positron Imaging Tomography (PET) is a non-invasive imaging technique that allows quantification and visualization of biochemical processes

  2. Invasive versus Non Invasive Methods Applied to Mummy Research: Will This Controversy Ever Be Solved?

    Science.gov (United States)

    Day, Jasmine; Bianucci, Raffaella

    2015-01-01

    Advances in the application of non invasive techniques to mummified remains have shed new light on past diseases. The virtual inspection of a corpse, which has almost completely replaced classical autopsy, has proven to be important especially when dealing with valuable museum specimens. In spite of some very rewarding results, there are still many open questions. Non invasive techniques provide information on hard and soft tissue pathologies and allow information to be gleaned concerning mummification practices (e.g., ancient Egyptian artificial mummification). Nevertheless, there are other fields of mummy studies in which the results provided by non invasive techniques are not always self-explanatory. Reliance exclusively upon virtual diagnoses can sometimes lead to inconclusive and misleading interpretations. On the other hand, several types of investigation (e.g., histology, paleomicrobiology, and biochemistry), although minimally invasive, require direct contact with the bodies and, for this reason, are often avoided, particularly by museum curators. Here we present an overview of the non invasive and invasive techniques currently used in mummy studies and propose an approach that might solve these conflicts. PMID:26345295

  3. Reflectance confocal microscopy: non-invasive distinction between actinic keratosis and squamous cell carcinoma

    NARCIS (Netherlands)

    Peppelman, M.; Nguyen, K.P.; Hoogedoorn, L.; Erp, P.E.J. van; Gerritsen, M.J.P.

    2015-01-01

    BACKGROUND: Early recognition of squamous cell carcinoma (SCC) is difficult. Non-invasive reflectance confocal microscopic (RCM) imaging of the skin is a promising diagnostic technique. Although several RCM features for SCC and AK have been described, it is not determined whether RCM has the ability

  4. Elastography methods for the non-invasive assessment of portal hypertension.

    Science.gov (United States)

    Roccarina, Davide; Rosselli, Matteo; Genesca, Joan; Tsochatzis, Emmanuel A

    2018-02-01

    The gold standard to assess the presence and severity of portal hypertension remains the hepatic vein pressure gradient, however the recent development of non-invasive assessment using elastography techniques offers valuable alternatives. In this review, we discuss the diagnostic accuracy and utility of such techniques in patients with portal hypertension due to cirrhosis. Areas covered: A literature search focused on liver and spleen stiffness measurement with different elastographic techniques for the assessment of the presence and severity of portal hypertension and oesophageal varices in people with chronic liver disease. The combination of elastography with parameters such as platelet count and spleen size is also discussed. Expert commentary: Non-invasive assessment of liver fibrosis and portal hypertension is a validated tool for the diagnosis and follow-up of patients. Baveno VI recommended the combination of transient elastography and platelet count for ruling out varices needing treatment in patients with compensated advanced chronic liver disease. Assessment of aetiology specific cut-offs for ruling in and ruling out clinically significant portal hypertension is an unmet clinical need. The incorporation of spleen stiffness measurements in non-invasive algorithms using validated software and improved measuring scales might enhance the non-invasive diagnosis of portal hypertension in the next 5 years.

  5. Non-invasive dendrochronology of late-medieval objects in Oslo

    DEFF Research Database (Denmark)

    Daly, Aoife; Streeton, Noëlle L.W.

    2017-01-01

    scanner. For these reasons, a combined approach was adopted, utilizing CT scanning where possible, but preceded by an ‘exposed-wood’ imaging technique. Both non-invasive techniques have yielded reliable results, and CT scanning has confirmed the reliability of the imaging technique alone. This paper...... presents the analytical methods, along with results from two of the 13 objects under investigation. Results for reliable dates and provenances provide new foundations for historical interpretations....

  6. Non-invasive monitoring of endocrine status in laboratory primates: methods, guidelines and applications

    Science.gov (United States)

    Heistermann, M.

    2010-11-01

    During the past three decades, non-invasive methods for assessing physiological, in particular endocrine, status have revolutionized almost all areas of primatology, including behavioural ecology, reproductive biology, stress research, conservation and last but not least management of primates in captivity where the technology plays an integral role in assisting the husbandry, breeding and welfare of many species. Non-invasive endocrine methods make use of the fact that hormones circulating in blood are secreted into saliva or deposited in hair and are eliminated from the body via urinary and faecal excretion. The choice of which matrix to use for hormonal assessment depends on a range of factors, including the type of information required, the measurement techniques involved, species differences in hormone metabolism and route of excretion and the practicality of sample collection. However, although sample collection is usually relatively easy, analysing hormones from these non-invasively collected samples is not as easy as many people think, particularly not when dealing with a new species. In this respect, the importance of a careful validation of each technique is essential in order to generate meaningful and accurate results. This paper aims to provide an overview of the available non-invasive endocrine-based methodologies, their relative merits and their potential areas of application for assessing endocrine status in primates, with special reference to captive environments. In addition, general information is given about the most important aspects and caveats researchers have to be aware of when using these methodologies.

  7. Non-invasive markers of atherosclerosis and their correlation with ...

    African Journals Online (AJOL)

    McRoy

    2014-07-26

    Jul 26, 2014 ... Study of non- invasive markers in patients with type 2 diabetes mellitus. Int J Med Biomed Res ... hypertension, smoking, and alcohol intake were documented for .... The risk of general CVD and hard CVD was significantly ...

  8. Non-invasive beamforming add-on module

    KAUST Repository

    Bader, Ahmed; Alouini, Mohamed-Slim

    2017-01-01

    An embodiment of a non-invasive beamforming add-on apparatus couples to an existing antenna port and rectifies the beam azimuth in the upstream and downstream directions. The apparatus comprises input circuitry that is configured to receive one

  9. Non-invasive vascular imaging: assessing tumour vascularity

    International Nuclear Information System (INIS)

    Delorme, S.; Knopp, M.V.

    1998-01-01

    Non-invasive assessment of vascularity is a new diagnostic approach to characterise tumours. Vascular assessment is based on the pathophysiology of tumour angiogenesis and its diagnostic implications for tumour biology, prognosis and therapy response. Two current techniques investigating vascular features in addition to morphology are Doppler ultrasonography and contrast-enhanced MRI. Diagnostic differentiation has been shown to be possible with Doppler, and a high degree of observed vascularity could be linked to an aggressive course of the disease. Dynamic MRI using gadolinium chelates is already used clinically to detect and differentiate tumours. The histological correlation shows that capillary permeability is increased in malignant tumours and is the best criterion for differentiation from benign processes. Permeability and perfusion factors seem to be more diagnostic than overall vessel density. New clinical applications are currently being established for therapy monitoring. Further instrumental developments will bring harmonic imaging in Doppler, and faster imaging techniques, higher spatial resolution and novel pharmacokinetic concepts in MRI. Upcoming contrast agents for both Doppler and MRI will further improve estimation of intratumoural blood volume and vascular permeability. (orig.)

  10. Diagnostic and prognostic value of non-invasive imaging in known or suspected coronary artery disease

    International Nuclear Information System (INIS)

    Schuijf, J.D.; Poldermans, D.; Shaw, L.J.; Jukema, J.W.; Wall, E.E. van der; Lamb, H.J.; Roos, A. de; Wijns, W.; Bax, J.J.

    2006-01-01

    The role of non-invasive imaging techniques in the evaluation of patients with suspected or known coronary artery disease (CAD) has increased exponentially over the past decade. The traditionally available imaging modalities, including nuclear imaging, stress echocardiography and magnetic resonance imaging (MRI), have relied on detection of CAD by visualisation of its functional consequences (i.e. ischaemia). However, extensive research is being invested in the development of non-invasive anatomical imaging using computed tomography or MRI to allow detection of (significant) atherosclerosis, eventually at a preclinical stage. In addition to establishing the presence of or excluding CAD, identification of patients at high risk for cardiac events is of paramount importance to determine post-test management, and the majority of non-invasive imaging tests can also be used for this purpose. The aim of this review is to provide an overview of the available non-invasive imaging modalities and their merits for the diagnostic and prognostic work-up in patients with suspected or known CAD. (orig.)

  11. Exploration of Hand Grasp Patterns Elicitable Through Non-Invasive Proximal Nerve Stimulation

    OpenAIRE

    Shin, Henry; Watkins, Zach; Hu, Xiaogang

    2017-01-01

    Various neurological conditions, such as stroke or spinal cord injury, result in an impaired control of the hand. One method of restoring this impairment is through functional electrical stimulation (FES). However, traditional FES techniques often lead to quick fatigue and unnatural ballistic movements. In this study, we sought to explore the capabilities of a non-invasive proximal nerve stimulation technique in eliciting various hand grasp patterns. The ulnar and median nerves proximal to th...

  12. Application of optical non-invasive methods in skin physiology

    Science.gov (United States)

    Lademann, J.; Patzelt, A.; Darvin, M.; Richter, H.; Antoniou, C.; Sterry, W.; Koch, S.

    2008-05-01

    In the present paper the application of optical non-invasive methods in dermatology and cosmetology is discussed. Laser scanning microscopy (LSM) and optical coherent tomography (OCT) are the most promising methods for this application. Using these methods, the analysis of different skin parameters like dryness and oiliness of the skin, the barrier function and the structure of furrows and wrinkles are discussed. Additionally the homogeneity of distribution of topically applied creams, as well as their penetration into the skin were investigated. It is shown that these methods are highly valuable in dermatology for diagnostic and therapy control and for basic research, for instance in the field of structure analysis of hair follicles and sweat glands. The vertical images of the tissue produced by OCT can be easily compared with histological sections. Unfortunately, the resolution of the OCT technique is not high enough to carry out measurements on a cellular level, as is possible by LSM. LSM has the advantage that it can be used for the investigation of penetration and storage processes of topically applied substances, if these substances have fluorescent properties or if they are fluorescent-labelled.

  13. Epilepsy surgery in children and non-invasive evaluation

    International Nuclear Information System (INIS)

    Hashizume, Kiyotaka; Sawamura, Atsushi; Yoshida, Katsunari; Tsuda, Hiroshige; Tanaka, Tatsuya; Tanaka, Shigeya

    2001-01-01

    The technique of EEG recording using subdural and depth electrodes has became established, and such invasive EEG is available for epilepsy surgery. However, a non-invasive procedure is required for evaluation of surgical indication for epilepsy patients, particular for children. We analyzed the relationship between the results of presurgical evaluation and seizure outcome, and investigated the role of invasive EEG in epilepsy surgery for children. Over the past decade, 22 children under 16 years of age have been admitted to our hospital for evaluation of surgical indication. High-resolution MR imaging, MR spectroscopy, video-EEG monitoring, and ictal and interictal SPECT were used for presurgical evaluation. Organic lesions were found on MR images from 19 patients. Invasive EEG was recorded in only one patient with occipital epilepsy, who had no lesion. Surgical indication was determined in 17 children, and 6 temporal lobe and 11 extratemporal lobe resections were performed under intraoperative electrocorticogram monitoring. The surgical outcome was excellent in 14 patients who had Engel's class I or II. Surgical complications occurred in two children who had visual field defects. The results showed that a good surgical outcome could be obtained using an intraoperative electrocorticogram, without presurgical invasive EEG, for localization-related epilepsy in children. The role of invasive EEG should be reevaluated in such children. (author)

  14. Epilepsy surgery in children and non-invasive evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, Kiyotaka; Sawamura, Atsushi; Yoshida, Katsunari; Tsuda, Hiroshige; Tanaka, Tatsuya [Asahikawa Medical Coll., Hokkaido (Japan); Tanaka, Shigeya

    2001-04-01

    The technique of EEG recording using subdural and depth electrodes has became established, and such invasive EEG is available for epilepsy surgery. However, a non-invasive procedure is required for evaluation of surgical indication for epilepsy patients, particular for children. We analyzed the relationship between the results of presurgical evaluation and seizure outcome, and investigated the role of invasive EEG in epilepsy surgery for children. Over the past decade, 22 children under 16 years of age have been admitted to our hospital for evaluation of surgical indication. High-resolution MR imaging, MR spectroscopy, video-EEG monitoring, and ictal and interictal SPECT were used for presurgical evaluation. Organic lesions were found on MR images from 19 patients. Invasive EEG was recorded in only one patient with occipital epilepsy, who had no lesion. Surgical indication was determined in 17 children, and 6 temporal lobe and 11 extratemporal lobe resections were performed under intraoperative electrocorticogram monitoring. The surgical outcome was excellent in 14 patients who had Engel's class I or II. Surgical complications occurred in two children who had visual field defects. The results showed that a good surgical outcome could be obtained using an intraoperative electrocorticogram, without presurgical invasive EEG, for localization-related epilepsy in children. The role of invasive EEG should be reevaluated in such children. (author)

  15. Application of optical non-invasive methods in skin physiology

    International Nuclear Information System (INIS)

    Lademann, J; Patzelt, A; Darvin, M; Richter, H; Sterry, W; Antoniou, C; Koch, S

    2008-01-01

    In the present paper the application of optical non-invasive methods in dermatology and cosmetology is discussed. Laser scanning microscopy (LSM) and optical coherent tomography (OCT) are the most promising methods for this application. Using these methods, the analysis of different skin parameters like dryness and oiliness of the skin, the barrier function and the structure of furrows and wrinkles are discussed. Additionally the homogeneity of distribution of topically applied creams, as well as their penetration into the skin were investigated. It is shown that these methods are highly valuable in dermatology for diagnostic and therapy control and for basic research, for instance in the field of structure analysis of hair follicles and sweat glands. The vertical images of the tissue produced by OCT can be easily compared with histological sections. Unfortunately, the resolution of the OCT technique is not high enough to carry out measurements on a cellular level, as is possible by LSM. LSM has the advantage that it can be used for the investigation of penetration and storage processes of topically applied substances, if these substances have fluorescent properties or if they are fluorescent-labelled

  16. Non-Invasive Measurement of Intracranial Pressure Pulsation using Ultrasound

    Science.gov (United States)

    Ueno, Toshiaki; Ballard, R. E.; Yost, W. T.; Hargens, A. R.

    1997-01-01

    Exposure to microgravity causes a cephalad fluid shift which may elevate intracranial pressure (ICP). Elevation in ICP may affect cerebral hemodynamics in astronauts during space flight. ICP is, however, a difficult parameter to measure due to the invasiveness of currently available techniques. We already reported our development of a non-invasive ultrasound device for measurement of ICP. We recently modified the device so that we might reproducibly estimate ICP changes in association with cardiac cycles. In the first experiment, we measured changes in cranial distance with the ultrasound device in cadavera while changing ICP by infusing saline into the lateral ventricle. In the second experiment, we measured changes in cranial distance in five healthy volunteers while placing them in 60 deg, 30 deg head-up tilt, supine, and 10 deg head-down tilt position. In the cadaver study, fast Fourier transformation revealed that cranial pulsation is clearly associated with ICP pulsation. The ratio of cranial distance and ICP pulsation is 1.3microns/mmHg. In the tilting study, the magnitudes of cranial pulsation are linearly correlated to tilt angles (r=0.87). The ultrasound device has sufficient sensitivity to detect cranial pulsation in association with cardiac cycles. By analyzing the magnitude of cranial pulsation, estimates of ICP during space flight are possible.

  17. Non-invasive measurements of carboxyhemoglobin and methemoglobin in children with sickle cell disease.

    Science.gov (United States)

    Caboot, Jason B; Jawad, Abbas F; McDonough, Joseph M; Bowdre, Cheryl Y; Arens, Raanan; Marcus, Carole L; Mason, Thornton B A; Smith-Whitley, Kim; Ohene-Frempong, Kwaku; Allen, Julian L

    2012-08-01

    Assessment of oxyhemoglobin saturation in patients with sickle cell disease (SCD) is vital for prompt recognition of hypoxemia. The accuracy of pulse oximeter measurements of blood oxygenation in SCD patients is variable, partially due to carboxyhemoglobin (COHb) and methemoglobin (MetHb), which decrease the oxygen content of blood. This study evaluated the accuracy and reliability of a non-invasive pulse co-oximeter in measuring COHb and MetHb percentages (SpCO and SpMet) in children with SCD. We hypothesized that measurements of COHb and MetHb by non-invasive pulse co-oximetry agree within acceptable clinical accuracy with those made by invasive whole blood co-oximetry. Fifty children with SCD-SS underwent pulse co-oximetry and blood co-oximetry while breathing room air. Non-invasive COHb and MetHb readings were compared to the corresponding blood measurements. The pulse co-oximeter bias was 0.1% for COHb and -0.22% for MetHb. The precision of the measured SpCO was ± 2.1% within a COHb range of 0.4-6.1%, and the precision of the measured SpMet was ± 0.33% within a MetHb range of 0.1-1.1%. Non-invasive pulse co-oximetry was useful in measuring COHb and MetHb levels in children with SCD. Although the non-invasive technique slightly overestimated the invasive COHb measurements and slightly underestimated the invasive MetHb measurements, there was close agreement between the two methods. Copyright © 2012 Wiley Periodicals, Inc.

  18. An Investigation of Pulse Transit Time as a Non-Invasive Blood Pressure Measurement Method

    International Nuclear Information System (INIS)

    McCarthy, B M; O'Flynn, B; Mathewson, A

    2011-01-01

    The objective of this paper is to examine the Pulse Transit Method (PTT) as a non-invasive means to track Blood Pressure over a short period of time. PTT was measured as the time it takes for an ECG R-wave to propagate to the finger, where it is detected by a photoplethysmograph sensor. The PTT method is ideal for continuous 24-hour Blood Pressure Measurement (BPM) since it is both cuff-less and non-invasive and therefore comfortable and unobtrusive for the patient. Other techniques, such as the oscillometric method, have shown to be accurate and reliable but require a cuff for operation, making them unsuitable for long term monitoring. Although a relatively new technique, the PTT method has shown to be able to accurately track blood pressure changes over short periods of time, after which re-calibration is necessary. The purpose of this study is to determine the accuracy of the method.

  19. Report on Non-invasive acoustic monitoring of D2O concentration Oct 31 2017

    Energy Technology Data Exchange (ETDEWEB)

    Pantea, Cristian [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sinha, Dipen N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lakis, Rollin Evan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Beedle, Christopher Craig [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Davis, Eric Sean [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-06

    There is an urgent need for real-time monitoring of the hydrogen /deuterium ratio (H/D) for heavy water production monitoring. Based upon published literature, sound speed is sensitive to the deuterium content of heavy water and can be measured using existing acoustic methods to determine the deuterium concentration in heavy water solutions. We plan to adapt existing non-invasive acoustic techniques (Swept-Frequency Acoustic Interferometry and Gaussian-pulse acoustic technique) for the purpose of quantifying H/D ratios in solution. A successful demonstration will provide an easily implemented, low cost, and non-invasive method for remote and unattended H/D ratio measurements with a resolution of less than 0.2% vol.

  20. Evaluation of four non-invasive methods for examination and characterization of pressure ulcers

    DEFF Research Database (Denmark)

    Andersen, E.S.; Karlsmark, T.

    2008-01-01

    Background: Pressure ulcers are globally of major concern and there is need for research in the pathogenesis for early intervention. Early studies have suggested existence of a hypo-echogenic subepidermal layer at the location of pressure ulcers, visualized by ultrasound scans. As a continuation......, we here report on usability of four non-invasive techniques for evaluation of pressure ulcers. Methods: Fifteen pressure ulcers in stage 0-IV were examined using four different non-invasive techniques [redness index, skin temperature, skin elasticity (i.e. retraction time), and ultrasound scanning...... at all pressure ulcers, but none at the reference points. The skin retraction time was often higher at the location of a pressure ulcer than at the reference location. We found no correlation between the stage of the ulcers and temperature, redness index, subepidermal layer thickness, or retraction time...

  1. Non-Invasive Assessment of Dairy Products Using SpatiallyResolved Diffuse Reflectance Spectroscopy

    DEFF Research Database (Denmark)

    Abildgaard, Otto Højager Attermann; Kamran, Faisal; Dahl, Anders Bjorholm

    2015-01-01

    of commercially available milk and yogurt products with three different levels of fat content are measured. These constitute a relevant range of products at a dairy plant. The measured reduced scattering properties of the samples are presented and show a clear discrimination between levels of fat contents as well...... as fermentation. The presented measurement technique and method of analysis is thus suitable for a rapid, noncontact, and non-invasive inspection that can deduce physically interpretable properties....

  2. Conservation genetics of otters: Review about the use of non-invasive samples

    OpenAIRE

    Aristizábal Duque, Sandra L.; Orozco-Jiménez, Luz Y.; Zapata-Escobar, Carolina; Palacio-Baena, Jaime A.

    2018-01-01

    Abstract: Wild population management programs require determining some fundamental aspects for conservation, including population structure, flow between populations, evolutionary history and kinship, among others. Since sample collection from wild mammals for DNA extraction is a complex task, conservation genetics has developed non-invasive sampling techniques, which allow obtaining DNA without the need to capture individuals. For the genetic characterization of otter populations, stools are...

  3. Non-invasive Assessments of Adipose Tissue Metabolism In Vitro.

    Science.gov (United States)

    Abbott, Rosalyn D; Borowsky, Francis E; Quinn, Kyle P; Bernstein, David L; Georgakoudi, Irene; Kaplan, David L

    2016-03-01

    Adipose tissue engineering is a diverse area of research where the developed tissues can be used to study normal adipose tissue functions, create disease models in vitro, and replace soft tissue defects in vivo. Increasing attention has been focused on the highly specialized metabolic pathways that regulate energy storage and release in adipose tissues which affect local and systemic outcomes. Non-invasive, dynamic measurement systems are useful to track these metabolic pathways in the same tissue model over time to evaluate long term cell growth, differentiation, and development within tissue engineering constructs. This approach reduces costs and time in comparison to more traditional destructive methods such as biochemical and immunochemistry assays and proteomics assessments. Towards this goal, this review will focus on important metabolic functions of adipose tissues and strategies to evaluate them with non-invasive in vitro methods. Current non-invasive methods, such as measuring key metabolic markers and endogenous contrast imaging will be explored.

  4. A non-invasive technique for age at death determination

    DEFF Research Database (Denmark)

    Lynnerup, N; Thomsen, I; Frohlich, B

    1990-01-01

    by identification of one of the five phases. An exact age determination of a single individual was not possible, but could be approximated to within 20 years. In forensic cases, however, where the removal of soft tissue is not always possible, this method can contribute to the final age determination when used...

  5. Actinic Keratosis and Non-Invasive Diagnostic Techniques: An Update

    Science.gov (United States)

    Casari, Alice; Chester, Johanna; Pellacani, Giovanni

    2018-01-01

    Actinic keratosis represents the earliest manifestation of non-melanoma skin cancer. Because of their risk of progression to invasive squamous cell carcinoma, an earlier diagnosis and treatment are mandatory. Their diagnosis sometimes could represent a challenge even for expert dermatologists. Dermoscopy, confocal laser microscopy and optical coherence tomography could help clinicians in diagnosis. PMID:29316678

  6. Non-invasive measurement of corneal hydration.

    Science.gov (United States)

    March, W F; Bauer, N J

    2001-01-01

    To investigate the feasibility of a confocal Raman spectroscopic technique for the noncontact assessment of corneal hydration in vivo in two legally blind subjects. A laser beam (632.8 nm; 15 mJ) was maintained on the cornea using a microscope objective lens (25x magnification, NA=0.5, f=10 mm) both for focusing the incident light as well as collecting the Raman backscattered light, in a 180 degrees backscatter configuration. An optical fiber, acting as the confocal pinhole for elimination of light from out-of-focus places, was coupled to a spectrometer that dispersed the collected light onto a sensitive array-detector for rapid spectral data acquisition over a range from 2,890 to 3,590 cm(-1). Raman spectra were recorded from the anterior 100 to 150 microm of the cornea over a period of time before and after topical application of a mild dehydrating solution. The ratio between the amplitudes of the signals at 3,400 cm(-1) (OH-vibrational mode of water) and 2,940 cm(-1) (CH-vibrational mode of proteins) was used as a measure of corneal hydration. High signal-to-noise ratio (SNR 25) Raman spectra were obtained from the human corneas using 15 mJ of laser light energy. Qualitative changes in the hydration of the anterior-most part of the corneas could be observed as a result of the dehydrating agent. Confocal Raman spectroscopy could potentially be applied clinically as a noncontact tool for the assessment of corneal hydration in vivo.

  7. Rejuvenecimiento periorbitario no invasivo Non-invasive periorbital rejuvenation

    Directory of Open Access Journals (Sweden)

    J. L. Muñóz del Olmo

    2008-03-01

    Full Text Available Cirujanos plásticos y médicos estéticos se esfuerzan por lograr resultados satisfactorios y estéticos que mejoren o suavicen el paso del tiempo a nivel facial, con un especial interés o énfasis en el área periorbitaria. Un gran número de pacientes consultan para mejorar esta zona, pero por diferentes motivos desean que los procedimientos que se les realicen sean poco invasivos y con resultados rápidos, permitiéndoles así incorporarse lo antes posible a sus actividades cotidianas. Es fundamental el conocimiento de las proporciones faciales y periorbitarias para lograr resultados naturales. El objetivo de la técnica que proponemos es lograr una bioestimulación local de la piel, restaurar los volúmenes y reducir las arrugas de expresión o dinámicas, consiguiendo así una apariencia relajada y juvenil en el paciente.Plastic surgeons and aesthetic doctors are making an effort to reach positive aesthetic results. Their aim is to soften the effects of age on facial features stressing in the periorbital area. Many patients come to improve their facial image on this area, but they are asking for non-invasive and fast procedures to keep on their daily life. It is indispensable the knowledge of facial and periorbital proportions to achieve a more natural effect. The aim of the technique exposed is to achieve a local bioestimulation on skin, to restore volumes and to reduce expression and dynamical wrinkles. The expected result is a relaxing, youthful appearance.

  8. Use of ECG and Other Simple Non-Invasive Tools to Assess Pulmonary Hypertension.

    Directory of Open Access Journals (Sweden)

    Gabor Kovacs

    Full Text Available There is a broad consensus that pulmonary hypertension (PH is to be diagnosed by right heart catheterization (RHC and that the most important non-invasive tool is echocardiography. However, the role of simple non-invasive tools in the work-up of PH is not clearly defined. We hypothesized that the use of simple non-invasive techniques may help to guide important decisions in the diagnostics of pulmonary hypertension.We aimed to develop an algorithm with the use of simple, non-invasive tools in order to identify patients with very high or very low likelihood of PH.We retrospectively analyzed all consecutive patients undergoing RHC between 2005 and 2010 in our center and performed logistic regression of simple non-invasive parameters regarding detection and exclusion of PH and derived a two-step algorithm. In a prospective study we evaluated this algorithm between 2011 and 2013.The retrospective cohort consisted of n = 394 patients of which 49% presented with PH. Right axis deviation in the ECG was present in 90/394 patients and had a positive predictive value (PPV of 93% for PH. The combination of non-right axis deviation, N-terminal pro brain natriuretic peptide (NT-proBNP<333pg/ml, arterial oxygen saturation (SO2≥95.5% and WHO functional class I-II was present in 69/394 patients and excluded PH with a negative predictive value (NPV of 96%. The prospective study confirmed these results in a cohort of n = 168 patients (PPV:92%, NPV:97%. Taken together, simple non-invasive tools allowed a prediction regarding the presence or absence of PH in 42% of patients with suspected PH.ECG, NT-proBNP, SO2 and WHO functional class may predict the presence or absence of PH in almost half of the patients with suspected PH, suggesting an important role for these variables in the work-up of patients at risk for PH.NCT01607502.

  9. Urinary biomarkers for the non-invasive diagnosis of endometriosis

    NARCIS (Netherlands)

    Liu, Emily; Nisenblat, Vicki; Farquhar, Cindy; Fraser, Ian; Bossuyt, Patrick M. M.; Johnson, Neil; Hull, M. Louise

    2015-01-01

    About 10% of reproductive-aged women suffer from endometriosis which is a costly chronic disease that causes pelvic pain and subfertility. Laparoscopy is the 'gold standard' diagnostic test for endometriosis, but it is expensive and carries surgical risks. Currently, there are no simple non-invasive

  10. Blood biomarkers for the non-invasive diagnosis of endometriosis

    NARCIS (Netherlands)

    Nisenblat, Vicki; Bossuyt, Patrick M. M.; Shaikh, Rabia; Farquhar, Cindy; Jordan, Vanessa; Scheffers, Carola S.; Mol, Ben Willem J.; Johnson, Neil; Hull, M. Louise

    2016-01-01

    About 10% of reproductive-aged women suffer from endometriosis, a costly chronic disease causing pelvic pain and subfertility. Laparoscopy is the gold standard diagnostic test for endometriosis, but is expensive and carries surgical risks. Currently, there are no non-invasive or minimally invasive

  11. A comparison of non-invasive versus invasive methods of ...

    African Journals Online (AJOL)

    Puneet Khanna

    for Hb estimation from the laboratory [total haemoglobin mass (tHb)] and arterial blood gas (ABG) machine (aHb), using ... A comparison of non-invasive versus invasive methods of haemoglobin estimation in patients undergoing intracranial surgery. 161 .... making decisions for blood transfusions based on these results.

  12. Non-invasive measurement of adrenocortical activity in a ...

    African Journals Online (AJOL)

    Measuring physiological stress reactions through the quantification of plasma cortisol often involves physical restraint, which acts as a stressor itself. Here, we present the validation of a non-invasive method for assessing adrenocortical activity as an indicator of stress in the bat-eared fox (Otocyon megalotis). By conducting ...

  13. Eyeblink Conditioning: A Non-Invasive Biomarker for Neurodevelopmental Disorders

    Science.gov (United States)

    Reeb-Sutherland, Bethany C.; Fox, Nathan A.

    2015-01-01

    Eyeblink conditioning (EBC) is a classical conditioning paradigm typically used to study the underlying neural processes of learning and memory. EBC has a well-defined neural circuitry, is non-invasive, and can be employed in human infants shortly after birth making it an ideal tool to use in both developing and special populations. In addition,…

  14. Non-invasive diagnosis and management of ectopic pregnancy

    NARCIS (Netherlands)

    van Mello, N.M.

    2013-01-01

    The work presented in this thesis begins with a focus on non-invasive diagnostic methods for ectopic pregnancy. The heterogeneity found in studies on diagnostic tests for ectopic pregnancy has led to an international recommendation on uniform definitions of early pregnancy complications. Hereafter,

  15. Non-invasive technology to determine the haemoglobin level of ...

    African Journals Online (AJOL)

    Background: Predonation haemoglobin (Hb) check has been done traditionally by the copper sulphate (CuSO4), or the haemocue haemoglobinometer methods. Both of these require a fingerprick of the donor to obtain capillary blood samples. It is thought that a non-invasive, but accurate method of Hb check will reduce ...

  16. Non-invasive terahertz field imaging inside parallel plate waveguides

    DEFF Research Database (Denmark)

    Iwaszczuk, Krzysztof; Andryieuski, Andrei; Lavrinenko, Andrei

    2011-01-01

    We present a non-invasive broadband air photonic method of imaging of the electric field of THz pulses propagating inside a tapered parallel plate waveguide. The method is based on field-enhanced second harmonic generation of the fundamental laser beam in an external electric field. We apply...

  17. Imaging modalities for the non-invasive diagnosis of endometriosis

    NARCIS (Netherlands)

    Nisenblat, Vicki; Bossuyt, Patrick M. M.; Farquhar, Cindy; Johnson, Neil; Hull, M. Louise

    2016-01-01

    About 10% of women of reproductive age suffer from endometriosis. Endometriosis is a costly chronic disease that causes pelvic pain and subfertility. Laparoscopy, the gold standard diagnostic test for endometriosis, is expensive and carries surgical risks. Currently, no non-invasive tests that can

  18. Plasma Atrial Natriuretic Peptide as a non-invasive biochemical ...

    African Journals Online (AJOL)

    Plasma Atrial Natriuretic Peptide as a non-invasive biochemical marker of dyspnoea in congestive heart failure patients. ... University of Mauritius Research Journal ... score assessed by a 10 graded visual analogue scale in the control group (mean score = 1) and an increased from 1.6 to 6.4 in the heart failure patients.

  19. Non-invasive in vivo measurement of macular carotenoids

    Science.gov (United States)

    Lambert, James L. (Inventor); Borchert, Mark S. (Inventor)

    2009-01-01

    A non-invasive in vivo method for assessing macular carotenoids includes performing Optical Coherence Tomography (OCT) on a retina of a subject. A spatial representation of carotenoid levels in the macula based on data from the OCT of the retina can be generated.

  20. Endometrial biomarkers for the non-invasive diagnosis of endometriosis

    NARCIS (Netherlands)

    Gupta, Devashana; Hull, M. Louise; Fraser, Ian; Miller, Laura; Bossuyt, Patrick M. M.; Johnson, Neil; Nisenblat, Vicki

    2016-01-01

    About 10% of reproductive-aged women suffer from endometriosis, which is a costly, chronic disease that causes pelvic pain and subfertility. Laparoscopy is the gold standard diagnostic test for endometriosis, but it is expensive and carries surgical risks. Currently, there are no non-invasive tests

  1. Blood biomarkers for the non-invasive diagnosis of endometriosis

    NARCIS (Netherlands)

    Nisenblat, Vicki; Bossuyt, Patrick M. M.; Shaikh, Rabia; Farquhar, Cindy; Jordan, Vanessa; Scheffers, Carola S.; Mol, Ben Willem J.; Johnson, Neil; Hull, M. Louise

    2016-01-01

    Background About 10% of reproductive-aged women suffer from endometriosis, a costly chronic disease causing pelvic pain and subfertility. Laparoscopy is the gold standard diagnostic test for endometriosis, but is expensive and carries surgical risks. Currently, there are no non-invasive or minimally

  2. Non-invasive nuclear device for communicating pressure inside a body to the exterior thereof

    International Nuclear Information System (INIS)

    Fleischmann, L.W.; Meyer, G.A.; Hittman, F.; Lyon, W.C.; Hayes, W.H. Jr.

    1979-01-01

    The need for a non-invasive technique for measuring the pressure in body cavities of animals or humans is recognized as highly desirable for continuous or intermittent monitoring of body conditions. The non-invasive nuclear device of the present invention is fully implantable and is fully capable of communicating pressure inside a body to the exterior to allow readout non-invasively. In its preferred form, the invention includes a housing for subcutaneous implantation with the radioactive source. An urging means such as a bellows is provided in the housing interior. The fluid pressure from a fluid pressure sensing device within the body is transmitted to the housing interior by means of a pressure-limiting fluid through a conduit. This causes the radioactive source to move against the force out of the initial or repose shielded relationship causing a proportional increase in pressure in the body portion being monitored. The radioactive output from the radioactive source corresponds to the magnitude of the pressure within the body. The housing may be securely mounted on a supporting portion of the body and the mounting serves as a radiation shield for the body. (JTA)

  3. Toenail as Non-invasive Biomarker in Metal Toxicity Measurement of Welding Fumes Exposure - A Review

    Science.gov (United States)

    Bakri, S. F. Z.; Hariri, A.; Ma'arop, N. F.; Hussin, N. S. A. W.

    2017-01-01

    Workers are exposed to a variety of heavy metal pollutants that are released into the environment as a consequence of workplace activities. This chemical pollutants are incorporated into the human by varies of routes entry and can then be stored and distributed in different tissues, consequently have a potential to lead an adverse health effects and/or diseases. As to minimize the impact, a control measures should be taken to avoid these effects and human biological marker is a very effective tool in the assessment of occupational exposure and potential related risk as the results is normally accurate and reproducible. Toenail is the ideal matrix for most common heavy metals due to its reliability and practicality compared to other biological samples as well as it is a non-invasive and this appears as a huge advantage of toenail as a biomarker. This paper reviews studies that measure the heavy metals concentration in toenail as non-invasive matrix which later may adapt in the investigation of metal fume emitted from welding process. The development of new methodology and modern analytical techniques has allowed the use of toenail as non-invasive approach. The presence of a heavy metal in this matrix reflects an exposure but the correlations between heavy metal levels in the toenail must be established to ensure that these levels are related to the total body burden. These findings suggest that further studies on interactions of these heavy metals in metal fumes utilizing toenail biomarker endpoints are highly warranted especially among welders.

  4. BrainStorm: a psychosocial game suite design for non-invasive cross-generational cognitive capabilities data collection

    Science.gov (United States)

    Ahmad, Faizan; Chen, Yiqiang; Hu, Lisha; Wang, Shuangquan; Wang, Jindong; Chen, Zhenyu; Jiang, Xinlong; Shen, Jianfei

    2017-11-01

    Currently available traditional as well as videogame-based cognitive assessment techniques are inappropriate due to several reasons. This paper presents a novel psychosocial game suite, BrainStorm, for non-invasive cross-generational cognitive capabilities data collection, which additionally provides cross-generational social support. A motivation behind the development of presented game suite is to provide an entertaining and exciting platform for its target users in order to collect gameplay-based cognitive capabilities data in a non-invasive manner. An extensive evaluation of the presented game suite demonstrated high acceptability and attraction for its target users. Besides, the data collection process is successfully reported as transparent and non-invasive.

  5. Non-invasive measurements of soil water content using a pulsed 14 MeV neutron generator

    Science.gov (United States)

    Most current techniques of setting crop irrigation schedules use invasive, labor-intensive soil-water content measurements. We developed a cart-mounted neutron probe capable of non-invasive measurements of volumetric soil moisture contents. The instrument emits neutrons which are captured by hydroge...

  6. NON-INVASIVE EVALUATION OF NERVE CONDUCTION IN SMALL DIAMETER FIBERS IN THE RAT

    OpenAIRE

    Zotova, Elena G.; Arezzo, Joseph C.

    2013-01-01

    A novel non-invasive technique was applied to measure velocity within slow conducting axons in the distal extreme of the sciatic nerve (i.e., digital nerve) in a rat model. The technique is based on the extraction of rectified multiple unit activity (MUA) from in vivo whole nerve compound responses. This method reliably identifies compound action potentials in thinly myelinated fibers conducting at a range of 9-18 m/s (Aδ axons), as well as in a subgroup of unmylinated C fibers conducting at ...

  7. Non-invasive optical detection of glucose in cell culture nutrient medium

    Science.gov (United States)

    Cote, Gerald L.

    1993-01-01

    The objective of the proposed research was to begin the development of a non-invasive optical sensor for measuring glucose concentration in the output medium of cell cultures grown in a unique NASA bioreactor referred to as an integrated rotating-wall vessel (IRWV). The input, a bovine serum based nutrient media, has a known glucose concentration. The cells within the bioreactor digest a portion of the glucose. Thus, the non-invasive optical sensor is needed to monitor the decrease in glucose due to cellular consumption since the critical parameters for sustained cellular productivity are glucose and pH. Previous glucose sensing techniques have used chemical reactions to quantify the glucose concentration. Chemical reactions, however, cannot provide for continuous, real time, non-invasive measurement as is required in this application. Our effort while in the fellowship program was focused on the design, optical setup, and testing of one bench top prototype non-invasive optical sensor using a mid-infrared absorption spectroscopy technique. Glucose has a fundamental vibrational absorption peak in the mid-infrared wavelength range at 9.6 micron. Preliminary absorption data using a CO2 laser were collected at this wavelength for water based glucose solutions at different concentrations and one bovine serum based nutrient medium (GTSF) with added glucose. The results showed near linear absorption responses for the glucose-in-water data with resolutions as high at 108 mg/dl and as low as 10 mg/dl. The nutrient medium had a resolution of 291 mg/dl. The variability of the results was due mainly to thermal and polarization drifts of the laser while the decrease in sensitivity to glucose in the nutrient medium was expected due to the increase in the number of confounders present in the nutrient medium. A multispectral approach needs to be used to compensate for these confounders. The CO2 laser used for these studies was wavelength tunable (9.2 to 10.8 micrometers), however

  8. New trend in non-invasive prenatal diagnosis.

    Science.gov (United States)

    Ferrari, M; Carrera, P; Lampasona, V; Galbiati, S

    2015-12-07

    The presence of fetal DNA in maternal plasma represents a source of genetic material which can be obtained non-invasively. To date, the translation of noninvasive prenatal diagnosis from research into clinical practice has been rather fragmented, and despite the advances in improving the analytical sensitivity of methods, distinguishing between fetal and maternal sequences remains very challenging. Thus, the field of noninvasive prenatal diagnosis of genetic diseases has yet to attain a routine application in clinical diagnostics. On the contrary, fetal sex determination in pregnancies at high risk of sex-linked disorders, tests for fetal RHD genotyping and non-invasive assessment of chromosomal aneuploidies are now available worldwide. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Non invasive brain stimulation to enhance post-stroke recovery

    Directory of Open Access Journals (Sweden)

    Nathalie Kubis

    2016-07-01

    Full Text Available Brain plasticity after stroke remains poorly understood. Patients may improve spontaneously within the first 3 months and then more slowly in the coming year. The first days, decreased edema and reperfusion of the ischemic penumbra may possibly account for these phenomena, but the improvement during the next weeks suggests plasticity phenomena and cortical reorganization of the brain ischemic areas and of more remote areas. Indeed, the injured ischemic motor cortex has a reduced cortical excitability at the acute phase and a suspension of the topographic representation of affected muscles, whereas the contralateral motor cortex has an increased excitability and an enlarged somatomotor representation; furthermore, contralateral cortex exerts a transcallosal interhemispheric inhibition on the ischemic cortex. This results from the imbalance of the physiological reciprocal interhemispheric inhibition of each hemisphere on the other, contributing to worsening of neurological deficit. Cortical excitability is measurable through transcranial magnetic stimulation (TMS and prognosis has been established according to the presence of motor evoked potentials (MEP at the acute phase of stroke, which is predictive of better recovery. Conversely, the lack of response to early stimulation is associated with a poor functional outcome. Non-invasive stimulation techniques such as repetitive TMS (rTMS or transcranial direct current stimulation (tDCS have the potential to modulate brain cortical excitability with long lasting effects. In the setting of cerebrovascular disease, around 1000 stroke subjects have been included in placebo-controlled trials so far, most often with an objective of promoting motor recovery of the upper limb. High frequency repetitive stimulation (> 3 Hz rTMS, aiming to increase excitability of the ischemic cortex, or low frequency repetitive stimulation (≤ 1 Hz, aiming to reduce excitability of the contralateral homonymous cortex, or

  10. Non-invasive biomarkers and pulmonary function in smokers

    OpenAIRE

    Borrill, Zo? L; Roy, Kay; Vessey, Rupert S; Woodcock, Ashley A; Singh, Dave

    2008-01-01

    Zoë L Borrill1, Kay Roy1, Rupert S Vessey2, Ashley A Woodcock1, Dave Singh11Medicines Evaluation Unit, University of Manchester, Wythenshawe Hospital, Southmoor Rd, Manchester, UK; 2Glaxo Smith Kline, Philadelphia, USAAbstract: Limited information exists regarding measurement, reproducibility and interrelationships of non-invasive biomarkers in smokers. We compared exhaled breath condensate (EBC) leukotriene B4 (LTB4) and 8-isoprostane, exhaled nitric oxide, induced sputum, spirometr...

  11. Applicability of non-invasively collected matrices for human biomonitoring

    Directory of Open Access Journals (Sweden)

    Nickmilder Marc

    2009-03-01

    Full Text Available Abstract With its inclusion under Action 3 in the Environment and Health Action Plan 2004–2010 of the European Commission, human biomonitoring is currently receiving an increasing amount of attention from the scientific community as a tool to better quantify human exposure to, and health effects of, environmental stressors. Despite the policy support, however, there are still several issues that restrict the routine application of human biomonitoring data in environmental health impact assessment. One of the main issues is the obvious need to routinely collect human samples for large-scale surveys. Particularly the collection of invasive samples from susceptible populations may suffer from ethical and practical limitations. Children, pregnant women, elderly, or chronically-ill people are among those that would benefit the most from non-invasive, repeated or routine sampling. Therefore, the use of non-invasively collected matrices for human biomonitoring should be promoted as an ethically appropriate, cost-efficient and toxicologically relevant alternative for many biomarkers that are currently determined in invasively collected matrices. This review illustrates that several non-invasively collected matrices are widely used that can be an valuable addition to, or alternative for, invasively collected matrices such as peripheral blood sampling. Moreover, a well-informed choice of matrix can provide an added value for human biomonitoring, as different non-invasively collected matrices can offer opportunities to study additional aspects of exposure to and effects from environmental contaminants, such as repeated sampling, historical overview of exposure, mother-child transfer of substances, or monitoring of substances with short biological half-lives.

  12. Thiomers: potential excipients for non-invasive peptide delivery systems.

    Science.gov (United States)

    Bernkop-Schnürch, Andreas; Krauland, Alexander H; Leitner, Verena M; Palmberger, Thomas

    2004-09-01

    In recent years thiolated polymers or so-called thiomers have appeared as a promising alternative in the arena of non-invasive peptide delivery. Thiomers are generated by the immobilisation of thiol-bearing ligands to mucoadhesive polymeric excipients. By formation of disulfide bonds with mucus glycoproteins, the mucoadhesive properties of these polymers are improved up to 130-fold. Due to formation of inter- and intramolecular disulfide bonds within the thiomer itself, dosage forms such as tablets or microparticles display strong cohesive properties resulting in comparatively higher stability, prolonged disintegration times and a more controlled release of the embedded peptide drug. The permeation of peptide drugs through mucosa can be improved by the use of thiolated polymers. Additionally some thiomers exhibit improved inhibitory properties towards peptidases. The efficacy of thiomers in non-invasive peptide delivery could be demonstrated by various in vivo studies. Tablets comprising a thiomer and pegylated insulin, for instance, resulted in a pharmacological efficacy of 7% after oral application to diabetic mice. Furthermore, a pharmacological efficacy of 1.3% was achieved in rats by oral administration of calcitonin tablets comprising a thiomer. Human growth hormone in a thiomer-gel was applied nasally to rats and led to a bioavailability of 2.75%. In all these studies, formulations comprising the corresponding unmodified polymer had only a marginal or no effect. According to these results drug carrier systems based on thiomers seem to be a promising tool for non-invasive peptide drug delivery.

  13. Current methods of non-invasive ventilatory support for neonates.

    Science.gov (United States)

    Mahmoud, Ramadan A; Roehr, Charles Christoph; Schmalisch, Gerd

    2011-09-01

    Non-invasive ventilatory support can reduce the adverse effects associated with intubation and mechanical ventilation, such as bronchopulmonary dysplasia, sepsis, and trauma to the upper airways. In the last 4 decades, nasal continuous positive airway pressure (CPAP) has been used to wean preterm infants off mechanical ventilation and, more recently, as a primary mode of respiratory support for preterm infants with respiratory insufficiency. Moreover, new methods of respiratory support have been developed, and the devices used to provide non-invasive ventilation (NIV) have improved technically. Use of NIV is increasing, and a variety of equipment is available in different clinical settings. There is evidence that NIV improves gas exchange and reduces extubation failure after mechanical ventilation in infants. However, more research is needed to identify the most suitable devices for particular conditions; the NIV settings that should be used; and whether to employ synchronized or non-synchronized NIV. Furthermore, the optimal treatment strategy and the best time for initiation of NIV remain to be identified. This article provides an overview of the use of non-invasive ventilation (NIV) in newborn infants, and the clinical applications of NIV. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Non-invasive genetic censusing and monitoring of primate populations.

    Science.gov (United States)

    Arandjelovic, Mimi; Vigilant, Linda

    2018-03-01

    Knowing the density or abundance of primate populations is essential for their conservation management and contextualizing socio-demographic and behavioral observations. When direct counts of animals are not possible, genetic analysis of non-invasive samples collected from wildlife populations allows estimates of population size with higher accuracy and precision than is possible using indirect signs. Furthermore, in contrast to traditional indirect survey methods, prolonged or periodic genetic sampling across months or years enables inference of group membership, movement, dynamics, and some kin relationships. Data may also be used to estimate sex ratios, sex differences in dispersal distances, and detect gene flow among locations. Recent advances in capture-recapture models have further improved the precision of population estimates derived from non-invasive samples. Simulations using these methods have shown that the confidence interval of point estimates includes the true population size when assumptions of the models are met, and therefore this range of population size minima and maxima should be emphasized in population monitoring studies. Innovations such as the use of sniffer dogs or anti-poaching patrols for sample collection are important to ensure adequate sampling, and the expected development of efficient and cost-effective genotyping by sequencing methods for DNAs derived from non-invasive samples will automate and speed analyses. © 2018 Wiley Periodicals, Inc.

  15. Non-invasive ventilation after surgery in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Olivieri, C; Castioni, C A; Livigni, S; Bersano, E; Cantello, R; Della Corte, F; Mazzini, L

    2014-04-01

    Surgery in patients affected by amyotrophic lateral sclerosis (ALS) presents a particular anesthetic challenge because of the risk of post-operative pulmonary complications. We report on the use of non-invasive ventilation (NIV) to prevent post-operative pulmonary complications (PPCs) in nine patients affected by ALS enrolled in a phase-1 clinical trial with stem cell transplantation. All patients were treated with autologous mesenchymal stem cells implanted into the spinal cord with a surgical procedure. Anesthesia was induced with propofol and maintained with remifentanil and sevoflurane. No muscle relaxant was used. After awakening and regain of spontaneous breathing, patients were tracheally extubated. Non-invasive ventilation through nasal mask was delivered and non-invasive positive pressure ventilation and continuous positive pressure ventilation were started. The average time on NIV after surgery was 3 h and 12 min. All patients regained stable spontaneous breathing after NIV discontinuation and had no episodes of respiratory failure until the following day. Our case series suggest that the use of NIV after surgery can be a safe strategy to prevent PPCs in patients affected by ALS. The perioperative procedure we chose for these patients appeared safe even in patients with advanced functional stage of the disease. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Role of non-invasive ventilation in difficult-to-wean children with acute neuromuscular disease.

    Science.gov (United States)

    Reddy, V G; Nair, M P; Bataclan, F

    2004-05-01

    Weaning from mechanical ventilation in children could be time-consuming and on many occasions, leads to reintubation with its associate complications. We report two children with acute neuromuscular disease, in whom bi-level positive airway pressure (BiPAP) as a mode of non-invasive ventilation was successfully used to wean the child from ventilators and prevented the need for tracheostomy. Despite the limited number of studies published in the literature suggesting BiPAP as a mode of weaning from mechanical ventilation, the technique when applied correctly seems to be safe and effective in weaning and avoiding tracheostomy.

  17. Invasive v non-invasive assessment of the carotid arteries prior to trans-sphenoidal surgery

    International Nuclear Information System (INIS)

    Macpherson, P.; Teasdale, E.; Hadley, D.M.; Teasdale, G.

    1987-01-01

    Imaging studies in 47 patients who were to undergo trans-sphenoidal surgery were analysed with reference to the vascular structures in the parasellar region. The results of cavernous sinography, dynamic contrast enhanced computed tomography (CT) and magnetic resonance imaging (MRI) showed good correlation with each other and with the appearances found at operation. CT and MRI, both non-invasive investigations, are therefore reliable preliminary screening methods for identifying the small proportion of patients on whom other imaging techniques need to be performed. (orig.)

  18. Non-Invasive Study of Nerve Fibres using Laser Interference Microscopy

    DEFF Research Database (Denmark)

    Brazhe, A. R.; Brazhe, N. A.; Rodionova, N. N.

    2008-01-01

    This paper presents the results of a laser interference microscopy study of the morphology and dynamical properties of myelinated nerve fibres. We describe the principles of operation of the phase-modulated laser interference microscope and show how this novel technique allows us to obtain...... information non-invasively about the internal structure of different regions of a nerve fibre. We also analyse the temporal variations in the internal optical properties in order to detect the rhythmic activity in the nerve fibre at different time scales and to shed light on the underlying biological...

  19. An alternative non-invasive treatment for Peyronie's disease

    Directory of Open Access Journals (Sweden)

    Joaquim A. Claro

    2004-06-01

    Full Text Available OBJECTIVE: Surgical correction of the deformity and plaque caused by Peyronie's disease has some important disadvantages and extracorporeal shockwave therapy (ESWT emerged as a new promising therapy. We evaluated prospectively the efficacy and safety of the association of high dose vitamin E and ESWT as a non-invasive treatment for the disease. MATERIALS AND METHODS: Twenty-five patients 42 to 68 years old (mean = 54 presenting penile deviation and sexual distress caused by Peyronie's disease were treated in a non-invasive manner. The time of penile deviation ranged from 16 to 52 months (mean = 30. All patients had previous unsuccessful treatment for Peyronie's disease. The angulation's deformity of the penis was assessed by photography at home. The patients received vitamin E (l.200 mg daily during 3 months and underwent 3 to 6 sessions (mean = 3 of ESWT (3,000 to 4,000 shockwaves at a power level of l to 2 at 1-week intervals. RESULTS: From 25 patients treated, 16 (64% reported an improvement in penile angulation, with a mean reduction of 21 degrees (10 to 40. Eight patients reported improvement in their spontaneous erections. Overall, the patients presented only minimal bruising at the site of treatment and skin hematoma. Four patients presented urethral bleeding. The mean angulation after treatment in the control group was 48.67 degrees (30 - 70 and in the study group was 24.42 degrees (0 - 70, statistically significant. CONCLUSION: Considering the common complications and the unsatisfactory outcome of the surgical correction for Peyronie's disease, the association of high dose vitamin E and ESWT represents a good option for a non-invasive, effective and safe treatment of the penile deformity.

  20. Non invasive methods for genetic analysis applied to ecological and behavioral studies in Latino-America

    Directory of Open Access Journals (Sweden)

    Susana González

    2007-07-01

    Full Text Available Documenting the presence and abundance of the neotropical mammals is the first step for understanding their population ecology, behavior and genetic dynamics in designing conservation plans. The combination of field research with molecular genetics techniques are new tools that provide valuable biological information avoiding the disturbance in the ecosystems, trying to minimize the human impact in the process to gather biological information. The objective of this paper is to review the available non invasive sampling techniques that have been used in Neotropical mammal studies to apply to determine the presence and abundance, population structure, sex ratio, taxonomic diagnostic using mitochondrial markers, and assessing genetic variability using nuclear markers. There are a wide range of non invasive sampling techniques used to determine the species identification that inhabit an area such as searching for tracks, feces, and carcasses. Other useful equipment is the camera traps that can generate an image bank that can be valuable to assess species presence and abundance by morphology. With recent advances in molecular biology, it is now possible to use the trace amounts of DNA in feces and amplify it to analyze the species diversity in an area, and the genetic variability at intraspecific level. This is particularly helpful in cases of sympatric and cryptic species in which morphology failed to diagnose the taxonomic status of several species of brocket deer of the genus Mazama.

  1. Non-invasive and non-destructive measurements of confluence in cultured adherent cell lines.

    Science.gov (United States)

    Busschots, Steven; O'Toole, Sharon; O'Leary, John J; Stordal, Britta

    2015-01-01

    Many protocols used for measuring the growth of adherent monolayer cells in vitro are invasive, destructive and do not allow for the continued, undisturbed growth of cells within flasks. Protocols often use indirect methods for measuring proliferation. Microscopy techniques can analyse cell proliferation in a non-invasive or non-destructive manner but often use expensive equipment and software algorithms. In this method images of cells within flasks are captured by photographing under a standard inverted phase contract light microscope using a digital camera with a camera lens adaptor. Images are analysed for confluence using ImageJ freeware resulting in a measure of confluence known as an Area Fraction (AF) output. An example of the AF method in use on OVCAR8 and UPN251 cell lines is included. •Measurements of confluence from growing adherent cell lines in cell culture flasks is obtained in a non-invasive, non-destructive, label-free manner.•The technique is quick, affordable and eliminates sample manipulation.•The technique provides an objective, consistent measure of when cells reach confluence and is highly correlated to manual counting with a haemocytometer. The average correlation co-efficient from a Spearman correlation (n = 3) was 0.99 ± 0.008 for OVCAR8 (p = 0.01) and 0.99 ± 0.01 for UPN251 (p = 0.01) cell lines.

  2. NON-INVASIVE EVALUATION OF NERVE CONDUCTION IN SMALL DIAMETER FIBERS IN THE RAT.

    Science.gov (United States)

    Zotova, Elena G; Arezzo, Joseph C

    2013-01-01

    A novel non-invasive technique was applied to measure velocity within slow conducting axons in the distal extreme of the sciatic nerve (i.e., digital nerve) in a rat model. The technique is based on the extraction of rectified multiple unit activity (MUA) from in vivo whole nerve compound responses. This method reliably identifies compound action potentials in thinly myelinated fibers conducting at a range of 9-18 m/s (Aδ axons), as well as in a subgroup of unmylinated C fibers conducting at approximately 1-2 m/s. The sensitivity of the method to C-fiber conduction was confirmed by the progressive decrement of the responses in the 1-2 m/s range over a 20-day period following the topical application of capsaicin (ANOVA p <0.03). Increasing the frequency of applied repetitive stimulation over a range of 0.75 Hz to 6.0 Hz produced slowing of conduction and a significant decrease in the magnitude of the compound C-fiber response (ANOVA p <0.01). This technique offers a unique opportunity for the non-invasive, repeatable, and quantitative assessment of velocity in the subsets of Aδ and C fibers in parallel with evaluation of fast nerve conduction.

  3. Biomechanics of subcellular structures by non-invasive Brillouin microscopy

    Science.gov (United States)

    Antonacci, Giuseppe; Braakman, Sietse

    2016-11-01

    Cellular biomechanics play a pivotal role in the pathophysiology of several diseases. Unfortunately, current methods to measure biomechanical properties are invasive and mostly limited to the surface of a cell. As a result, the mechanical behaviour of subcellular structures and organelles remains poorly characterised. Here, we show three-dimensional biomechanical images of single cells obtained with non-invasive, non-destructive Brillouin microscopy with an unprecedented spatial resolution. Our results quantify the longitudinal elastic modulus of subcellular structures. In particular, we found the nucleoli to be stiffer than both the nuclear envelope (p biomechanics and its role in pathophysiology.

  4. Towards a smart non-invasive fluid loss measurement system.

    Science.gov (United States)

    Suryadevara, N K; Mukhopadhyay, S C; Barrack, L

    2015-04-01

    In this article, a smart wireless sensing non-invasive system for estimating the amount of fluid loss, a person experiences while physical activity is presented. The system measures three external body parameters, Heart Rate, Galvanic Skin Response (GSR, or skin conductance), and Skin Temperature. These three parameters are entered into an empirically derived formula along with the user's body mass index, and estimation for the amount of fluid lost is determined. The core benefit of the developed system is the affluence usage in combining with smart home monitoring systems to care elderly people in ambient assisted living environments as well in automobiles to monitor the body parameters of a motorist.

  5. Non-invasive PGAA, PIXE and ToF-ND analyses on Hungarian Bronze Age defensive armour

    International Nuclear Information System (INIS)

    Marianne Moedlinger; Imre Kovacs; Zoltan Szoekefalvi-Nagy; Ziad El Morr

    2014-01-01

    Non-invasive, archaeometric analyses on selected Hungarian Bronze Age defensive armour is presented here: three greaves, three helmets two shields as well as one vessel fragment were analysed with PIXE, PGAA and TOF-ND. The detected alloy elemental and phase composition as well as its intergranular or spatial concentration distribution reveals important insights into the alloys used and the manufacturing techniques applied c. 1200-950 BC, and allows to reconstruct the production techniques used during the Late Bronze Age. (author)

  6. Current status and future of non-invasive studies of human brain functions

    International Nuclear Information System (INIS)

    Shibasaki, Hiroshi

    2008-01-01

    Currently available non-invasive studies are divided into two groups: electrophysiological studies and functional neuroimaging based on the hemodynamic principle. The former includes electroencephalography (EEG), magnetoencephalography (MEG) and transcranial magnetic stimulation, and the latter includes functional MRI, positron emission tomography (PET), single photon emission computed tomography (SPECT) and near-infrared spectroscopy. The hemodynamic response has been shown to be correlated with neuronal electrical activity, especially with synaptic activity rather than spiking activity, within a certain range. Since each technique has advantage and disadvantage, it is important to apply the most appropriate technique to solve each specific question. The combined use of more than one techniques of different principles, if possible, provides data of higher spatial and temporal resolution. Functional connectivity among different brain areas can be studied by using some of these techniques either alone or in combination. (author)

  7. Non-invasive brain-to-brain interface (BBI: establishing functional links between two brains.

    Directory of Open Access Journals (Sweden)

    Seung-Schik Yoo

    Full Text Available Transcranial focused ultrasound (FUS is capable of modulating the neural activity of specific brain regions, with a potential role as a non-invasive computer-to-brain interface (CBI. In conjunction with the use of brain-to-computer interface (BCI techniques that translate brain function to generate computer commands, we investigated the feasibility of using the FUS-based CBI to non-invasively establish a functional link between the brains of different species (i.e. human and Sprague-Dawley rat, thus creating a brain-to-brain interface (BBI. The implementation was aimed to non-invasively translate the human volunteer's intention to stimulate a rat's brain motor area that is responsible for the tail movement. The volunteer initiated the intention by looking at a strobe light flicker on a computer display, and the degree of synchronization in the electroencephalographic steady-state-visual-evoked-potentials (SSVEP with respect to the strobe frequency was analyzed using a computer. Increased signal amplitude in the SSVEP, indicating the volunteer's intention, triggered the delivery of a burst-mode FUS (350 kHz ultrasound frequency, tone burst duration of 0.5 ms, pulse repetition frequency of 1 kHz, given for 300 msec duration to excite the motor area of an anesthetized rat transcranially. The successful excitation subsequently elicited the tail movement, which was detected by a motion sensor. The interface was achieved at 94.0±3.0% accuracy, with a time delay of 1.59±1.07 sec from the thought-initiation to the creation of the tail movement. Our results demonstrate the feasibility of a computer-mediated BBI that links central neural functions between two biological entities, which may confer unexplored opportunities in the study of neuroscience with potential implications for therapeutic applications.

  8. Non-invasive coronary angiography with multislice computed tomography. Technology, methods, preliminary experience and prospects.

    Science.gov (United States)

    Traversi, Egidio; Bertoli, Giuseppe; Barazzoni, Giancarlo; Baldi, Maurizia; Tramarin, Roberto

    2004-02-01

    The recent technical developments in multislice computed tomography (MSCT), with ECG retro-gated image reconstruction, have elicited great interest in the possibility of accurate non-invasive imaging of the coronary arteries. The latest generation of MSCT systems with 8-16 rows of detectors permits acquisition of the whole cardiac volume during a single 15-20 s breath-hold with a submillimetric definition of the images and an outstanding signal-to-noise ratio. Thus the race which, between MSCT, electron beam computed tomography and cardiac magnetic resonance imaging, can best provide routine and reliable imaging of the coronary arteries in clinical practice has recommenced. Currently available MSCT systems offer different options for both cardiac image acquisition and reconstruction, including multiplanar and curved multiplanar reconstruction, three-dimensional volume rendering, maximum intensity projection, and virtual angioscopy. In our preliminary experience including 176 patients suffering from known or suspected coronary artery disease, MSCT was feasible in 161 (91.5%) and showed a sensitivity of 80.4% and a specificity of 80.3%, with respect to standard coronary angiography, in detecting critical stenosis in coronary arteries and artery or venous bypass grafts. These results correspond to a positive predictive value of 58.6% and a negative predictive value of 92.2%. The true role that MSCT is likely to play in the future in non-invasive coronary imaging is still to be defined. Nevertheless, the huge amount of data obtainable by MSCT along with the rapid technological advances, shorter acquisition times and reconstruction algorithm developments will make the technique stronger, and possible applications are expected not only for non-invasive coronary angiography, but also for cardiac function and myocardial perfusion evaluation, as an all-in-one examination.

  9. Clinical role of non-invasive assessment of portal hypertension.

    Science.gov (United States)

    Bolognesi, Massimo; Di Pascoli, Marco; Sacerdoti, David

    2017-01-07

    Measurement of portal pressure is pivotal in the evaluation of patients with liver cirrhosis. The measurement of the hepatic venous pressure gradient represents the reference method by which portal pressure is estimated. However, it is an invasive procedure that requires significant hospital resources, including experienced staff, and is associated with considerable cost. Non-invasive methods that can be reliably used to estimate the presence and the degree of portal hypertension are urgently needed in clinical practice. Biochemical and morphological parameters have been proposed for this purpose, but have shown disappointing results overall. Splanchnic Doppler ultrasonography and the analysis of microbubble contrast agent kinetics with contrast-enhanced ultrasonography have shown better accuracy for the evaluation of patients with portal hypertension. A key advancement in the non-invasive evaluation of portal hypertension has been the introduction in clinical practice of methods able to measure stiffness in the liver, as well as stiffness/congestion in the spleen. According to the data published to date, it appears to be possible to rule out clinically significant portal hypertension in patients with cirrhosis ( i.e ., hepatic venous pressure gradient ≥ 10 mmHg) with a level of clinically-acceptable accuracy by combining measurements of liver stiffness and spleen stiffness along with Doppler ultrasound evaluation. It is probable that the combination of these methods may also allow for the identification of patients with the most serious degree of portal hypertension, and ongoing research is helping to ensure progress in this field.

  10. Measurement of non-invasive X-ray measuring instruments

    International Nuclear Information System (INIS)

    Abe, Shinji

    2013-01-01

    Described are the history, measuring system, characteristics and present state of the instruments in the title (NXMI). NXMI, non-invasive to the inner circuit of X-ray generator, is now essential for the quality control of generator with reference to definitions by International Electrotechnical Commission (IEC) and Japan Industrial Standards (JIS). Non-invasive measurement of the generator's tube voltage in 1944 is the first report where the absorption difference of Cu plates with different thickness is used. At present, NXMI, being compact, can measure multiple properties of X-ray generated, such as the tube voltage (TV), current (TC), imaging time, dose/dose rate, total filtration, half value layer, and TV/output waveform. TV is measurable by the penetration difference of X-rays through Cu filters of different thickness, which is a linear function of TV; TC, with the clamp-type ammeter placed at the generator high voltage cable; and the dose, with the semiconductor detector. Characteristics can be evaluable within the upper trigger level of the detector (radiation time, dose measured here), in which measured are the irradiation (imaging) time, delay time, and TV (within the window width). Authors' practical quality control of the generator is conducted through calibration for which data are obtained by invasive (direct) precise measurement of TV, TC, imaging time and dose with reference to JIS. Periodical calibration and consequent quality control of NXMI are essential for the maintenance of precision of the generator. (T.T.)

  11. Influence of hemoglobin on non-invasive optical bilirubin sensing

    Science.gov (United States)

    Jiang, Jingying; Gong, Qiliang; Zou, Da; Xu, Kexin

    2012-03-01

    Since the abnormal metabolism of bilirubin could lead to diseases in the human body, especially the jaundice which is harmful to neonates. Traditional invasive measurements are difficult to be accepted by people because of pain and infection. Therefore, the real-time and non-invasive measurement of bilirubin is of great significance. However, the accuracy of currently transcutaneous bilirubinometry(TcB) is generally not high enough, and affected by many factors in the human skin, mostly by hemoglobin. In this talk, absorption spectra of hemoglobin and bilirubin have been collected and analyzed, then the Partial Least Squares (PLS) models have been built. By analyzing and comparing the Correlation and Root Mean Square Error of Prediction(RMSEP), the results show that the Correlation of bilirubin solution model is larger than that of the mixture solution added with hemoglobin, and its RMSEP value is smaller than that of mixture solution. Therefore, hemoglobin has influences on the non-invasive optical bilirubin sensing. In next step, it is necessary to investigate how to eliminate the influence.

  12. Clinical evaluation of non-invasive perfusion-weighted MRI

    International Nuclear Information System (INIS)

    Takasu, Miyuki

    2000-01-01

    A spin labeling method to measure cerebral blood flow without a contrast medium was developed and applied clinically to obtain a non-invasive perfusion-weighted image. The purpose of this study is to compare the non-invasive perfusion-weighted image using FAIR with the well-established PWI using a bolus injection of Gd-DTPA. Of 41 lesions which revealed decreased perfusion, 13 were shown to be low signal intensity areas on FAIR. Therefore, detection rate of FAIR for hypoperfusion was 32%. Of 8 lesions which revealed increased perfusion, 7 demonstrated high intensity on FAIR. Therefore, detection rate of FAIR for hyperperfusion was 88%. Seven lesions were found to have a mean pixel value of zero on PWI. Of these lesions, 5 lesions could be detected as high signal intensity area on FAIR. The rCBV- and rCBF index ratios of hypoperfused lesions detected on FAIR were significantly lower than those of lesions which were not detected on FAIR (p=0.007, p=0.01). As concerns the lesions detected of FAIR, there were positive correlation between rCBV- or rCBF index ratio and FAIR signal ratio (rCBV ratio: ρ=0.873, p=0.0002, rCBF index ratio: ρ=0.858, p=0.0003). FAIR is valuable clinical tool to detect perfusion abnormality semi-quantitatively without contrast medium, although it showed relatively low detection rate for hypoperfused lesions. (author)

  13. Comparison of different models for non-invasive FFR estimation

    Science.gov (United States)

    Mirramezani, Mehran; Shadden, Shawn

    2017-11-01

    Coronary artery disease is a leading cause of death worldwide. Fractional flow reserve (FFR), derived from invasively measuring the pressure drop across a stenosis, is considered the gold standard to diagnose disease severity and need for treatment. Non-invasive estimation of FFR has gained recent attention for its potential to reduce patient risk and procedural cost versus invasive FFR measurement. Non-invasive FFR can be obtained by using image-based computational fluid dynamics to simulate blood flow and pressure in a patient-specific coronary model. However, 3D simulations require extensive effort for model construction and numerical computation, which limits their routine use. In this study we compare (ordered by increasing computational cost/complexity): reduced-order algebraic models of pressure drop across a stenosis; 1D, 2D (multiring) and 3D CFD models; as well as 3D FSI for the computation of FFR in idealized and patient-specific stenosis geometries. We demonstrate the ability of an appropriate reduced order algebraic model to closely predict FFR when compared to FFR from a full 3D simulation. This work was supported by the NIH, Grant No. R01-HL103419.

  14. Sleep-related breathing disorders and non-invasive ventilation

    Directory of Open Access Journals (Sweden)

    Agata Lax

    2015-05-01

    Full Text Available Non-invasive mechanical ventilation (NPPV was originally used in patients with acute respiratory impairment or exacerbations of chronic respiratory diseases, as an alternative to the endotracheal tube. Over the last thirty years NPPV has been also used at night in patients with stable chronic lung disease such as obstructive sleep apnea, the overlap syndrome (chronic obstructive pulmonary disease and obstructive sleep apnea, neuromuscular disorders, obesity-hypoventilation syndrome, and in other conditions such as sleep disorders associated with congestive heart failure (Cheyne-Stokes respiration. In this no-systematic review we discuss the different types of NPPV, the specific conditions in which they can be used and the indications, recommendations and evidence supporting the efficacy of NPPV. Optimizing patient acceptance and adherence to non-invasive ventilation treatment is challenging. The treatment of sleep-related disorders is a life-threatening condition. The optimal level of treatment should be determined in a sleep laboratory. Side effects directly affecting the patient’s adherence to treatment are known. The most common are nasopharyngeal symptoms including increased congestion and rhinorrhea; these effects are related to reduced humidity of inspired gas. Humidification of delivered gas may improve these symptoms.

  15. Non-invasive in-situ investigations versus micro-sampling: a comparative study on a Renoirs painting

    International Nuclear Information System (INIS)

    Miliani, C.; Sgamellotti, A.; Universita degli Studi di Perugia . Centro di Eccellenza SMAArt; Scientific Methodologies applied to Archaeology and Art)

    2007-01-01

    In this paper, a multi-technique in-situ non-invasive approach has been followed for the study of the materials used for a painting by Pierre-Auguste Renoir, ''A woman at her toilette''. The study was carried out using five portable spectroscopic techniques, namely X-ray fluorescence, mid-infrared reflectance spectroscopy, near infrared reflectance spectroscopy, and UV-Vis spectroscopy in absorption and emission. The painting was selected as a case study because it was examined in advance of the current investigation using conventional micro-sampling techniques. This provided the opportunity to evaluate potential and limitations of the non-invasive approach to the complex case of the modern painting. (orig.)

  16. Development of an X-ray Computed Tomography System for Non-Invasive Imaging of Industrial Materials

    International Nuclear Information System (INIS)

    Abdullah, J.; Sipaun, S. M.; Mustapha, I.; Zain, R. M.; Rahman, M. F. A.; Mustapha, M.; Shaari, M. R.; Hassan, H.; Said, M. K. M.; Mohamad, G. H. P.; Ibrahim, M. M.

    2008-01-01

    X-ray computed tomography is a powerful non-invasive imaging technique for viewing an object's inner structures in two-dimensional cross-section images without the need to physically section it. The invention of CT techniques revolutionised the field of medical diagnostic imaging because it provided more detailed and useful information than any previous non-invasive imaging techniques. The method is increasingly being used in industry, aerospace, geosciences and archaeology. This paper describes the development of an X-ray computed tomography system for imaging of industrial materials. The theoretical aspects of CT scanner, the system configurations and the adopted algorithm for image reconstruction are discussed. The penetrating rays from a 160 kV industrial X-ray machine were used to investigate structures that manifest in a manufactured component or product. Some results were presented in this paper

  17. Non-invasive imaging of zebrafish with spinal deformities using optical coherence tomography: a preliminary study

    Science.gov (United States)

    Bernstein, Liane; Beaudette, Kathy; Patten, Kessen; Beaulieu-Ouellet, Émilie; Strupler, Mathias; Moldovan, Florina; Boudoux, Caroline

    2013-03-01

    A zebrafish model has recently been introduced to study various genetic mutations that could lead to spinal deformities such as scoliosis. However, current imaging techniques make it difficult to perform longitudinal studies of this condition in zebrafish, especially in the early stages of development. The goal of this project is to determine whether optical coherence tomography (OCT) is a viable non-invasive method to image zebrafish exhibiting spinal deformities. Images of both live and fixed malformed zebrafish (5 to 21 days postfertilization) as well as wild-type fish (5 to 29 days postfertilization) were acquired non-invasively using a commercial SD-OCT system, with a laser source centered at 930nm (λ=100nm), permitting axial and lateral resolutions of 7 and 8μm respectively. Using two-dimensional images and three-dimensional reconstructions, it was possible to identify the malformed notochord as well as deformities in other major organs at different stages of formation. Visualization of the notochord was facilitated with the development of a segmentation algorithm. OCT images were compared to HE histological sections and images obtained by calcein staining. Because of the possibility of performing longitudinal studies on a same fish and reducing image processing time as compared with staining techniques and histology, the use of OCT could facilitate phenotypic characterization in studying genetic factors leading to spinal deformities in zebrafish and could eventually contribute to the identification of the genetic causes of spinal deformities such as scoliosis.

  18. Review of invasive urodynamics and progress towards non-invasive measurements in the assessment of bladder outlet obstruction

    Directory of Open Access Journals (Sweden)

    C J Griffiths

    2009-01-01

    Full Text Available Objective: This article defines the need for objective measurements to help diagnose the cause of lower urinary tract symptoms (LUTS. It describes the conventional techniques available, mainly invasive, and then summarizes the emerging range of non-invasive measurement techniques. Methods: This is a narrative review derived form the clinical and scientific knowledge of the authors together with consideration of selected literature. Results: Consideration of measured bladder pressure urinary flow rate during voiding in an invasive pressure flow study is considered the gold standard for categorization of bladder outlet obstruction (BOO. The diagnosis is currently made by plotting the detrusor pressure at maximum flow (p detQmax and maximum flow rate (Q max on the nomogram approved by the International Continence Society. This plot will categorize the void as obstructed, equivocal or unobstructed. The invasive and relatively complex nature of this investigation has led to a number of inventive techniques to categorize BOO either by measuring bladder pressure non-invasively or by providing a proxy measure such as bladder weight. Conclusion: Non-invasive methods of diagnosing BOO show great promise and a few have reached the stage of being commercially available. Further studies are however needed to validate the measurement technique and assess their worth in the assessment of men with LUTS.

  19. Non-invasive pulsed cavitational ultrasound for fetal tissue ablation: feasibility study in a fetal sheep model.

    Science.gov (United States)

    Kim, Y; Gelehrter, S K; Fifer, C G; Lu, J C; Owens, G E; Berman, D R; Williams, J; Wilkinson, J E; Ives, K A; Xu, Z

    2011-04-01

    Currently available fetal intervention techniques rely on invasive procedures that carry inherent risks. A non-invasive technique for fetal intervention could potentially reduce the risk of fetal and obstetric complications. Pulsed cavitational ultrasound therapy (histotripsy) is an ablation technique that mechanically fractionates tissue at the focal region using extracorporeal ultrasound. In this study, we investigated the feasibility of using histotripsy as a non-invasive approach to fetal intervention in a sheep model. The experiments involved 11 gravid sheep at 102-129 days of gestation. Fetal kidney, liver, lung and heart were exposed to ultrasound pulses (bones. Histological assessment confirmed lesion locations and sizes corresponding to regions where cavitation was monitored, with no lesions found when cavitation was absent. Inability to generate cavitation was primarily associated with increased depth to target and obstructing structures such as fetal limbs. Extracorporeal histotripsy therapy successfully created targeted lesions in fetal sheep organs without significant damage to overlying structures. With further improvements, histotripsy may evolve into a viable technique for non-invasive fetal intervention procedures. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

  20. Non-invasive in situ Examination of Colour Changes of Blue Paints in Danish Golden Age Paintings

    DEFF Research Database (Denmark)

    Buti, David; Vila, Anna; Filtenborg, Troels Folke

    A non-invasive study of some paintings containing areas of paint with a Prussian blue component has been conducted at the Statens Museum for Kunst. The in situ campaign has been carried out with a range of different spectroscopic portable techniques, provided by the MOLAB transnational access...... of the frame. Prussian blue is a hydrated iron(III) hexacyanoferrate(II) complex of variable composition depending on the manufacturing [1]. It has been reported that the method of preparation, as well as the use of white pigments or extenders to dilute the blue pigment, may be a factor contributing to its......, the current in situ campaign aimed at mapping and understanding the degradation of Prussian blue and lead white admixtures using non-invasive portable techniques. The presence of Prussian blue was detected, with the MOLAB analytical means, in all the exposed, faded areas, although the colour had turned pale...

  1. Electromyography data for non-invasive naturally-controlled robotic hand prostheses.

    Science.gov (United States)

    Atzori, Manfredo; Gijsberts, Arjan; Castellini, Claudio; Caputo, Barbara; Hager, Anne-Gabrielle Mittaz; Elsig, Simone; Giatsidis, Giorgio; Bassetto, Franco; Müller, Henning

    2014-01-01

    Recent advances in rehabilitation robotics suggest that it may be possible for hand-amputated subjects to recover at least a significant part of the lost hand functionality. The control of robotic prosthetic hands using non-invasive techniques is still a challenge in real life: myoelectric prostheses give limited control capabilities, the control is often unnatural and must be learned through long training times. Meanwhile, scientific literature results are promising but they are still far from fulfilling real-life needs. This work aims to close this gap by allowing worldwide research groups to develop and test movement recognition and force control algorithms on a benchmark scientific database. The database is targeted at studying the relationship between surface electromyography, hand kinematics and hand forces, with the final goal of developing non-invasive, naturally controlled, robotic hand prostheses. The validation section verifies that the data are similar to data acquired in real-life conditions, and that recognition of different hand tasks by applying state-of-the-art signal features and machine-learning algorithms is possible.

  2. Non-invasive and micro-destructive investigation of the Domus Aurea wall painting decorations.

    Science.gov (United States)

    Clementi, Catia; Ciocan, Valeria; Vagnini, Manuela; Doherty, Brenda; Tabasso, Marisa Laurenzi; Conti, Cinzia; Brunetti, Brunetto Giovanni; Miliani, Costanza

    2011-10-01

    The paper reports on the exploitation of an educated multi-technique analytical approach based on a wide non invasive step followed by a focused micro-destructive step, aimed at the minimally invasive identification of the pigments decorating the ceiling of the Gilded Vault of the Domus Aurea in Rome. The combination of elemental analysis with molecular characterization provided by X-ray fluorescence and UV-vis spectroscopies, respectively, allowed for the in situ non-invasive identification of a remarkable number of pigments, namely Egyptian blue, green earth, cinnabar, red ochre and an anthraquinonic lake. The study was completed with the Raman analysis of two bulk samples, in particular, SERS measurements allowed for the speciation of the anthraquinonic pigment. Elemental mapping by scanning electron microscopy-energy dispersive spectrometer combined with micro-fluorimetry on cross-section gave an insight into both the distribution of different blend of pigments and on the nature of the inorganic support of the red dye.

  3. Non-invasive monitoring of muscle blood perfusion by photoplethysmography: evaluation of a new application.

    Science.gov (United States)

    Sandberg, M; Zhang, Q; Styf, J; Gerdle, B; Lindberg, L-G

    2005-04-01

    To evaluate a specially developed photoplethysmographic (PPG) technique, using green and near-infrared light sources, for simultaneous non-invasive monitoring of skin and muscle perfusion. Evaluation was based on assessments of changes in blood perfusion to various provocations, such as post-exercise hyperaemia and hyperaemia following the application of liniment. The deep penetrating feature of PPG was investigated by measurement of optical radiation inside the muscle. Simultaneous measurements using ultrasound Doppler and the new PPG application were performed to elucidate differences between the two methods. Specific problems related to the influence of skin temperature on blood flow were highlightened, as well. Following static and dynamic contractions an immediate increase in muscle perfusion was shown, without increase in skin perfusion. Liniment application to the skin induced a rapid increase in skin perfusion, but not in muscle. Both similarities and differences in blood flow measured by Ultrasound Doppler and PPG were demonstrated. The radiant power measured inside the muscle, by use of an optical fibre, showed that the near-infrared light penetrates down to the vascular depth inside the muscle. The results of this study indicate the potentiality of the method for non-invasive measurement of local muscle perfusion, although some considerations still have to be accounted for, such as influence of temperature on blood perfusion.

  4. Novel algorithm for non-invasive assessment of fibrosis in NAFLD.

    Directory of Open Access Journals (Sweden)

    Jan-Peter Sowa

    Full Text Available INTRODUCTION: Various conditions of liver disease and the downsides of liver biopsy call for a non-invasive option to assess liver fibrosis. A non-invasive score would be especially useful to identify patients with slow advancing fibrotic processes, as in Non-Alcoholic Fatty Liver Disease (NAFLD, which should undergo histological examination for fibrosis. PATIENTS/METHODS: Classic liver serum parameters, hyaluronic acid (HA and cell death markers of 126 patients undergoing bariatric surgery for morbid obesity were analyzed by machine learning techniques (logistic regression, k-nearest neighbors, linear support vector machines, rule-based systems, decision trees and random forest (RF. Specificity, sensitivity and accuracy of the evaluated datasets to predict fibrosis were assessed. RESULTS: None of the single parameters (ALT, AST, M30, M60, HA did differ significantly between patients with a fibrosis score 1 or 2. However, combining these parameters using RFs reached 79% accuracy in fibrosis prediction with a sensitivity of more than 60% and specificity of 77%. Moreover, RFs identified the cell death markers M30 and M65 as more important for the decision than the classic liver parameters. CONCLUSION: On the basis of serum parameters the generation of a fibrosis scoring system seems feasible, even when only marginally fibrotic tissue is available. Prospective evaluation of novel markers, i.e. cell death parameters, should be performed to identify an optimal set of fibrosis predictors.

  5. Non-Invasive Ventilation in Patients with Heart Failure: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Hugo Souza Bittencourt

    Full Text Available Abstract Non-invasive ventilation (NIV may perfect respiratory and cardiac performance in patients with heart failure (HF. The objective of the study to establish, through systematic review and meta-analysis, NIV influence on functional capacity of HF patients. A systematic review with meta-analysis of randomized studies was carried out through research of databases of Cochrane Library, SciELO, Pubmed and PEDro, using the key-words: heart failure, non-invasive ventilation, exercise tolerance; and the free terms: bi-level positive airway pressure (BIPAP, continuous positive airway pressure (CPAP, and functional capacity (terms were searched for in English and Portuguese using the Boolean operators AND and OR. Methodological quality was ensured through PEDro scale. Weighted averages and a 95% confidence interval (CI were calculated. The meta-analysis was done thorugh the software Review Manager, version 5.3 (Cochrane Collaboration. Four randomized clinical trials were included. Individual studies suggest NIV improved functional capacity. NIV resulted in improvement in the distance of the six-minute walk test (6MWT (68.7m 95%CI: 52.6 to 84.9 in comparison to the control group. We conclude that the NIV is an intervention that promotes important effects in the improvement of functional capacity of HF patients. However, there is a gap in literature on which are the most adequate parameters for the application of this technique.

  6. Cell-baswd non-invasive prenatal testing

    DEFF Research Database (Denmark)

    Uldbjerg, Niels; Singh, Ripudaman; Christensen, Rikke

    that fetal cells are stable in blood samples stored up to 48 hours. Using these cells, we have detected subchromosomal abnormalities including one with mosaic 45, X/46, X, r(X) which have been confirmed at DNA from chorion villus sampling. Conclusions: We conclude that fcmb-NIPT deserves full attention......CONTROL ID: 2520273 ABSTRACT FINAL ID: OC06.03 TITLE: Cell based Non-invasive Prenatal Testing (NIPT) AUTHORS (FIRST NAME, LAST NAME): Niels Uldbjerg2, Ripudaman Singh4, Rikke Christensen3, Palle Schelde4, Ida Vogel1, Else Marie Vestergaard3, Lotte Hatt4, Steen Kølvrå4 INSTITUTIONS (ALL): 1...... therefore hypothesize that NIPT based on amplified DNA from fetal cells circulating in maternal blood (fcmb-NIPT) will make it possible to detect subchromosomal aberrations. Methods: We obtained 30 ml of whole blood from 100 pregnant women undergoing chorion villus sampling at a gestational age of 10...

  7. Non-invasive beamforming add-on module

    KAUST Repository

    Bader, Ahmed

    2017-02-23

    An embodiment of a non-invasive beamforming add-on apparatus couples to an existing antenna port and rectifies the beam azimuth in the upstream and downstream directions. The apparatus comprises input circuitry that is configured to receive one or more signals from a neighboring node of the linear wireless sensor network; first amplifier circuitry configured to adjust an amplitude of a respective received signal in accordance with a weighting coefficient and invoke a desired phase to a carrier frequency of the received signal thereby forming a first amplified signal; and second amplifier circuitry configured to adjust a gain of the first amplified signal towards upstream and downstream neighbors of the linear wireless sensor in the linear wireless sensor network.

  8. Non-invasive examination of multiple sclerosis patients

    International Nuclear Information System (INIS)

    Weerd, A.W. de.

    1981-01-01

    Multiple sclerosis is characterized by a wide range of symptoms and, in many cases, by a highly erratic course. As a result diagnosis is often a problem. Two non-invasive examinations, Computer Tomography (CT scan) and the Evoked Response test (ER), are the subjects of this study which, according to available literature, both can play a role in the establishment of the diagnosis of multiple sclerosis. Clinical trials have been performed and both methods demonstrated abnormalities of the central nervous system which were not suspected on clinical grounds; as a result both methods of examination can contribute to the early establishment of the diagnosis of multiple sclerosis. In addition the diagnosis can be determined with greater certainty when the findings of the CT-scan and the evoked response test are taken into consideration. (Auth.)

  9. Estimation of blood pressure from non-invasive data.

    Science.gov (United States)

    Shukla, Satya Narayan

    2017-07-01

    Blood pressure (BP) is one of the most important physiological parameter that can provide crucial information for health care. The widely used cuff based technology is not very convenient or comfortable as it occludes the blood flow in the arteries during the time of measurement. In past, Phonocardiogram (PCG), Electrocardiogram (ECG) and Photoplethysmogram (PPG) signals have been used to predict the BP values. In this paper, we propose to estimate the blood pressure from PPG using Multi Task Gaussian Processes (MTGPs) and compare with Artificial Neural networks (ANNs). Both MTGPs and ANNs are evaluated on the clinical data obtained from MIMIC Database. The performance of the proposed method is found to be comparable or better than the existing methods of computing BP from non-invasive data.

  10. Non-Invasive in vivo Imaging in Small Animal Research

    Directory of Open Access Journals (Sweden)

    V. Koo

    2006-01-01

    Full Text Available Non-invasive real time in vivo molecular imaging in small animal models has become the essential bridge between in vitro data and their translation into clinical applications. The tremendous development and technological progress, such as tumour modelling, monitoring of tumour growth and detection of metastasis, has facilitated translational drug development. This has added to our knowledge on carcinogenesis. The modalities that are commonly used include Magnetic Resonance Imaging (MRI, Computed Tomography (CT, Positron Emission Tomography (PET, bioluminescence imaging, fluorescence imaging and multi-modality imaging systems. The ability to obtain multiple images longitudinally provides reliable information whilst reducing animal numbers. As yet there is no one modality that is ideal for all experimental studies. This review outlines the instrumentation available together with corresponding applications reported in the literature with particular emphasis on cancer research. Advantages and limitations to current imaging technology are discussed and the issues concerning small animal care during imaging are highlighted.

  11. Non-invasive examination method for cerebrovascular diseases

    International Nuclear Information System (INIS)

    Chiba, Kazuo

    1979-01-01

    CT is superior in the diagnosis of the characteristics and the region of cerebrovascular diseases (CVD) to the examination with RI. The RI examination can only demonstrate the cerebrovascular diseases with large area disturbance of the cerebral cortex, that passed some days after the attack. Moreover, it is difficult to detect the small lesions or the lesions localized in the deep area such as the basal nucleus and the internal capsule by this method. A slight decrease and retardation in unilateral cerebral blood flow (under 20%, within 1.5 second) found by RI-angiography does not always indicate the side of the lesion of cerebrovascular diseases. It is expected that non-invasive examination method for CVD is improved more, and that more precise estimation method for regional cerebral circulation is developed. (Tsunoda, M.)

  12. Non-invasive clinical measurements of bone mineral

    International Nuclear Information System (INIS)

    Mazess, R.B.

    1982-01-01

    Non-invasive methods are now available for measurement of both compact and trabecular bone on both the appendicular and axial skeleton. Radiogrammetry and photodensitometry both are subject to large errors in areas of heavy tissue cover but precise measurements can be made on the hand bones. Single-photon absorptiometry with 125 I provides a more accurate and precise measure of appendicular compact bone, which is particularly useful for screening of metabolic bone disease and for monitoring renal osteodystrophy. Dual-photon absorptiometry with 153 Gd provides a measurement of the femoral neck and of the lumbar spine and hence is the most diagnostically sensitive measurement method. It is also the most sensitive for monitoring bone changes

  13. Invasive and non-invasive brain stimulation for treatment of neuropathic pain in patients with spinal cord injury: a review.

    Science.gov (United States)

    Nardone, Raffaele; Höller, Yvonne; Leis, Stefan; Höller, Peter; Thon, Natasha; Thomschewski, Aljoscha; Golaszewski, Stefan; Brigo, Francesco; Trinka, Eugen

    2014-01-01

    Past evidence has shown that invasive and non-invasive brain stimulation may be effective for relieving central pain. To perform a topical review of the literature on brain neurostimulation techniques in patients with chronic neuropathic pain due to traumatic spinal cord injury (SCI) and to assess the current evidence for their therapeutic efficacy. A MEDLINE search was performed using following terms: "Spinal cord injury", "Neuropathic pain", "Brain stimulation", "Deep brain stimulation" (DBS), "Motor cortex stimulation" (MCS), "Transcranial magnetic stimulation" (TMS), "Transcranial direct current stimulation" (tDCS), "Cranial electrotherapy stimulation" (CES). Invasive neurostimulation therapies, in particular DBS and epidural MCS, have shown promise as treatments for neuropathic and phantom limb pain. However, the long-term efficacy of DBS is low, while MCS has a relatively higher potential with lesser complications that DBS. Among the non-invasive techniques, there is accumulating evidence that repetitive TMS can produce analgesic effects in healthy subjects undergoing laboratory-induced pain and in chronic pain conditions of various etiologies, at least partially and transiently. Another very safe technique of non-invasive brain stimulation - tDCS - applied over the sensory-motor cortex has been reported to decrease pain sensation and increase pain threshold in healthy subjects. CES has also proved to be effective in managing some types of pain, including neuropathic pain in subjects with SCI. A number of studies have begun to use non-invasive neuromodulatory techniques therapeutically to relieve neuropathic pain and phantom phenomena in patients with SCI. However, further studies are warranted to corroborate the early findings and confirm different targets and stimulation paradigms. The utility of these protocols in combination with pharmacological approaches should also be explored.

  14. New tools for non-invasive exploration of collagen network in cartilaginous tissue-engineered substitute.

    Science.gov (United States)

    Henrionnet, Christel; Dumas, Dominique; Hupont, Sébastien; Stoltz, Jean François; Mainard, Didier; Gillet, Pierre; Pinzano, Astrid

    2017-01-01

    In tissue engineering approaches, the quality of substitutes is a key element to determine its ability to treat cartilage defects. However, in clinical practice, the evaluation of tissue-engineered cartilage substitute quality is not possible due to the invasiveness of the standard procedure, which is to date histology. The aim of this work was to validate a new innovative system performed from two-photon excitation laser adapted to an optical macroscope to evaluate at macroscopic scale the collagen network in cartilage tissue-engineered substitutes in confrontation with gold standard histologic techniques or immunohistochemistry to visualize type II collagen. This system permitted to differentiate the quality of collagen network between ITS and TGF-β1 treatments. Multiscale large field imaging combined to multimodality approaches (SHG-TCSPC) at macroscopical scale represent an innovative and non-invasive technique to monitor the quality of collagen network in cartilage tissue-engineered substitutes before in vivo implantation.

  15. A technical guide to tDCS, and related non-invasive brain stimulation tools

    Science.gov (United States)

    Woods, AJ; Antal, A; Bikson, M; Boggio, PS; Brunoni, AR; Celnik, P; Cohen, LG; Fregni, F; Herrmann, CS; Kappenman, ES; Knotkova, H; Liebetanz, D; Miniussi, C; Miranda, PC; Paulus, W; Priori, A; Reato, D; Stagg, C; Wenderoth, N; Nitsche, MA

    2015-01-01

    Transcranial electrical stimulation (tES), including transcranial direct and alternating current stimulation (tDCS, tACS) are non-invasive brain stimulation techniques increasingly used for modulation of central nervous system excitability in humans. Here we address methodological issues required for tES application. This review covers technical aspects of tES, as well as applications like exploration of brain physiology, modelling approaches, tES in cognitive neurosciences, and interventional approaches. It aims to help the reader to appropriately design and conduct studies involving these brain stimulation techniques, understand limitations and avoid shortcomings, which might hamper the scientific rigor and potential applications in the clinical domain. PMID:26652115

  16. Cardiac tumours: non invasive detection and assessment by gated cardiac blood pool radionuclide imaging

    International Nuclear Information System (INIS)

    Pitcher, D.; Wainwright, R.; Brennand-Roper, D.; Deverall, P.; Sowton, E.; Maisey, M.

    1980-01-01

    Four patients with cardiac tumours were investigated by gated cardiac blood pool radionuclide imaging and echocardiography. Contrast angiocardiography was performed in three of the cases. Two left atrial tumours were detected by all three techniques. In one of these cases echocardiography alone showed additional mitral valve stenosis, but isotope imaging indicated tumour size more accurately. A large septal mass was detected by all three methods. In this patient echocardiography showed evidence of left ventricular outflow obstruction, confirmed at cardiac catheterisation, but gated isotope imaging provided a more detailed assessment of the abnormal cardiac anatomy. In the fourth case gated isotope imaging detected a large right ventricular tumour which had not been identified by echocardiography. Gated cardiac blood pool isotope imaging is a complementary technique to echocardiography for the non-invasive detection and assessment of cardiac tumours. (author)

  17. Insights into Parkinson's disease models and neurotoxicity using non-invasive imaging

    International Nuclear Information System (INIS)

    Sanchez-Pernaute, Rosario; Brownell, Anna-Liisa; Jenkins, Bruce G.; Isacson, Ole

    2005-01-01

    Loss of dopamine in the nigrostriatal system causes a severe impairment in motor function in patients with Parkinson's disease and in experimental neurotoxic models of the disease. We have used non-invasive imaging techniques such as positron emission tomography (PET) and functional magnetic resonance imaging (MRI) to investigate in vivo the changes in the dopamine system in neurotoxic models of Parkinson's disease. In addition to classic neurotransmitter studies, in these models, it is also possible to characterize associated and perhaps pathogenic factors, such as the contribution of microglia activation and inflammatory responses to neuronal damage. Functional imaging techniques are instrumental to our understanding and modeling of disease mechanisms, which should in turn lead to development of new therapies for Parkinson's disease and other neurodegenerative disorders

  18. The importance of optical methods for non-invasive measurements in the skin care industry

    Science.gov (United States)

    Stamatas, Georgios N.

    2010-02-01

    Pharmaceutical and cosmetic industries are concerned with treating skin disease, as well as maintaining and promoting skin health. They are dealing with a unique tissue that defines our body in space. As such, skin provides not only the natural boundary with the environment inhibiting body dehydration as well as penetration of exogenous aggressors to the body, it is also ideally situated for optical measurements. A plurality of spectroscopic and imaging methods is being used to understand skin physiology and pathology and document the effects of topically applied products on the skin. The obvious advantage of such methods over traditional biopsy techniques is the ability to measure the cutaneous tissue in vivo and non-invasively. In this work, we will review such applications of various spectroscopy and imaging methods in skin research that is of interest the cosmetic and pharmaceutical industry. Examples will be given on the importance of optical techniques in acquiring new insights about acne pathogenesis and infant skin development.

  19. Development and application of non-invasive biomarkers for carcinogen-DNA adduct analysis in occupationally exposed populations.

    Science.gov (United States)

    Talaska, G; Cudnik, J; Jaeger, M; Rothman, N; Hayes, R; Bhatnagar, V J; Kayshup, S J

    1996-07-17

    Biological monitoring of exposures to carcinogenic compounds in the workplace can be a valuable adjunct to environmental sampling and occupational medicine. Carcinogen-DNA adduct analysis has promise as a biomarker of effective dose if target organ samples can be obtained non-invasively. We have developed non-invasive techniques using exfoliated urothelial and bronchial cells collected in urine and sputum, respectively. First morning urine samples were collected from 33 workers exposed to benzidine or benzidine-based dyes and controls matched for age, education, and smoking status. Sufficient DNA for 32P-postlabelling analysis was obtained from every sample. Mean levels of a specific DNA adduct (which co-chromatographed with standard characterized by MS) were elevated significantly in the benzidine-exposed workers relative to controls. In addition, workers exposed to benzidine had higher adduct levels than those exposed to benzidine-based dyes. This study demonstrates the usefulness of these non-invasive techniques for exposure/effect assessment. To be useful in occupational studies, biomarkers must also be sensitive to exposure interventions. We have conducted topical application studies of used gasoline engine oils in mice and found that the levels of carcinogen-DNA adducts in skin and lung can be significantly lowered if skin cleaning is conducted in a timely manner. The combination of useful, non-invasive techniques to monitor exposure and effect and industrial hygiene interventions can be used to detect and prevent exposures to a wide range of carcinogens including those found in used gasoline engine oils and jet exhausts.

  20. Tissue Damage Characterization Using Non-invasive Optical Modalities

    Science.gov (United States)

    Diaz, David

    The ability to determine the degree of cutaneous and subcutaneous tissue damage is essential for proper wound assessment and a significant factor for determining patient treatment and morbidity. Accurate characterization of tissue damage is critical for a number of medical applications including surgical removal of nonviable tissue, severity assessment of subcutaneous ulcers, and depth assessment of visually open wounds. The main objective of this research was to develop a non-invasive method for identifying the extent of tissue damage underneath intact skin that is not apparent upon visual examination. This work investigated the relationship between tissue optical properties, blood flow, and tissue viability by testing the hypotheses that (a) changes in tissue oxygenation and/or microcirculatory blood flow measurable by Diffuse Near Infrared Spectroscopy (DNIRS) and Diffuse Correlation Spectroscopy (DCS) differ between healthy and damaged tissue and (b) the magnitude of those changes differs for different degrees of tissue damage. This was accomplished by developing and validating a procedure for measuring microcirculatory blood flow and tissue oxygenation dynamics at multiple depths (up to 1 centimeter) using non-invasive DCS and DNIRS technologies. Due to the lack of pressure ulcer animal models that are compatible with our optical systems, a proof of concept was conducted in a porcine burn model prior to conducting clinical trials in order to assess the efficacy of the system in-vivo. A reduction in total hemoglobin was observed for superficial (5%) and deep burns (35%) along with a statistically significant difference between the optical properties of superficial and deep burns (p differences detected in optical properties and hemoglobin content by optical measurements correlated with the extent of tissue injury observed in histological stains. After proof of concept in animals, a human study was conducted and optical data was collected from 20 healthy

  1. Optimal Non-Invasive Fault Classification Model for Packaged Ceramic Tile Quality Monitoring Using MMW Imaging

    Science.gov (United States)

    Agarwal, Smriti; Singh, Dharmendra

    2016-04-01

    Millimeter wave (MMW) frequency has emerged as an efficient tool for different stand-off imaging applications. In this paper, we have dealt with a novel MMW imaging application, i.e., non-invasive packaged goods quality estimation for industrial quality monitoring applications. An active MMW imaging radar operating at 60 GHz has been ingeniously designed for concealed fault estimation. Ceramic tiles covered with commonly used packaging cardboard were used as concealed targets for undercover fault classification. A comparison of computer vision-based state-of-the-art feature extraction techniques, viz, discrete Fourier transform (DFT), wavelet transform (WT), principal component analysis (PCA), gray level co-occurrence texture (GLCM), and histogram of oriented gradient (HOG) has been done with respect to their efficient and differentiable feature vector generation capability for undercover target fault classification. An extensive number of experiments were performed with different ceramic tile fault configurations, viz., vertical crack, horizontal crack, random crack, diagonal crack along with the non-faulty tiles. Further, an independent algorithm validation was done demonstrating classification accuracy: 80, 86.67, 73.33, and 93.33 % for DFT, WT, PCA, GLCM, and HOG feature-based artificial neural network (ANN) classifier models, respectively. Classification results show good capability for HOG feature extraction technique towards non-destructive quality inspection with appreciably low false alarm as compared to other techniques. Thereby, a robust and optimal image feature-based neural network classification model has been proposed for non-invasive, automatic fault monitoring for a financially and commercially competent industrial growth.

  2. Combining non-invasive transcranial brain stimulation with neuroimaging and electrophysiology: Current approaches and future perspectives

    DEFF Research Database (Denmark)

    Bergmann, Til Ole; Karabanov, Anke; Hartwigsen, Gesa

    2016-01-01

    Non-invasive transcranial brain stimulation (NTBS) techniques such as transcranial magnetic stimulation (TMS) and transcranial current stimulation (TCS) are important tools in human systems and cognitive neuroscience because they are able to reveal the relevance of certain brain structures...... are technically demanding. We argue that the benefit from this combination is twofold. Firstly, neuroimaging and electrophysiology can inform subsequent NTBS, providing the required information to optimize where, when, and how to stimulate the brain. Information can be achieved both before and during the NTBS...... experiment, requiring consecutive and concurrent applications, respectively. Secondly, neuroimaging and electrophysiology can provide the readout for neural changes induced by NTBS. Again, using either concurrent or consecutive applications, both "online" NTBS effects immediately following the stimulation...

  3. 201thallium myocardial scintigraphy. A non-invasive method for diagnosis of ischaemic heart disease

    International Nuclear Information System (INIS)

    Kyst Madsen, J.; Utne, H.E.

    1982-01-01

    Myocardial perfusion scintigraphy with the isotope 201 thallium is a new non-invasive technique for the diagnosis of ischaemic heart disease. This article presents the results of scintigraphy in four persons with presumably healthy hearts and 12 with ischaemic heart disease. In addition, some foreign works are reviewed. The method possesses only slightly greater nosographical sensitivity than the exercise ECG alone but can be employed to advantage if the results of the exercise ECG are inconclusive e.g. on account of bundle branch block, digoxin therapy etc. Another, although somewhat more special indication, is employment prior to and after coronary artery by-pass operation with subsequent control of the result. (authors)

  4. Non-invasive assessment of muscle stiffness in patients with Duchenne muscular dystrophy.

    Science.gov (United States)

    Lacourpaille, Lilian; Hug, François; Guével, Arnaud; Péréon, Yann; Magot, Armelle; Hogrel, Jean-Yves; Nordez, Antoine

    2015-02-01

    Assessment of muscle mechanical properties may provide clinically valuable information for follow-up of patients with Duchenne muscular dystrophy (DMD) through the course of their disease. In this study we aimed to assess the effect of DMD on stiffness of relaxed muscles using elastography (supersonic shear imaging). Fourteen DMD patients and 13 control subjects were studied. Six muscles were measured at 2 muscle lengths (shortened and stretched): gastrocnemius medialis (GM); tibialis anterior (TA); vastus lateralis (VL); biceps brachii (BB); triceps brachii (TB); and abductor digiti minimi (ADM). Stiffness was significantly higher in DMD patients compared with controls for all the muscles (main effect for population, P muscle lengths) to large (d = 0.86 for BB/stretched). Supersonic shear imaging is a sensitive non-invasive technique to assess the increase in muscle stiffness associated with DMD. © 2014 Wiley Periodicals, Inc.

  5. Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization

    International Nuclear Information System (INIS)

    Wróbel, M.S.

    2016-01-01

    The number of patients with diabetes has reached over 350 million, and still continues to increase. The need for regular blood glucose monitoring sparks the interest in the development of modern detection technologies. One of those methods, which allows for noninvasive measurements, is Raman spectroscopy. The ability of infrared light to penetrate deep into tissues allows for obtaining measurements through the skin without its perforation. This paper presents the limitations and possibilities of non-invasive blood glucose monitoring with Raman spectroscopy. Especially focusing on the possibilities for device miniaturization. Such device incorporates a Raman spectrometer, a fiber-optical probe, and a computing device (microcontroller, smartphone, etc.) which calculates the glucose concentration using specialized algorithms. Simplification of device design, as well as turbidity correction technique and a new proposed method of synchronized detection are described

  6. Non-invasive imaging of skin cancer with fluorescence lifetime imaging using two photon tomography

    Science.gov (United States)

    Patalay, Rakesh; Talbot, Clifford; Alexandrov, Yuriy; Munro, Ian; Breunig, Hans Georg; König, Karsten; Warren, Sean; Neil, Mark A. A.; French, Paul M. W.; Chu, Anthony; Stamp, Gordon W.; Dunsby, Christopher

    2011-07-01

    Multispectral fluorescence lifetime imaging (FLIM) using two photon microscopy as a non-invasive technique for the diagnosis of skin lesions is described. Skin contains fluorophores including elastin, keratin, collagen, FAD and NADH. This endogenous contrast allows tissue to be imaged without the addition of exogenous agents and allows the in vivo state of cells and tissues to be studied. A modified DermaInspect® multiphoton tomography system was used to excite autofluorescence at 760 nm in vivo and on freshly excised ex vivo tissue. This instrument simultaneously acquires fluorescence lifetime images in four spectral channels between 360-655 nm using time-correlated single photon counting and can also provide hyperspectral images. The multispectral fluorescence lifetime images were spatially segmented and binned to determine lifetimes for each cell by fitting to a double exponential lifetime model. A comparative analysis between the cellular lifetimes from different diagnoses demonstrates significant diagnostic potential.

  7. Non-invasive assessment of vessel morphology and function in tumors by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kiessling, Fabian; Jugold, Manfred; Woenne, Eva C.; Brix, Gunnar

    2007-01-01

    The switch to an angiogenic phenotype is an important precondition for tumor growth, invasion and spread. Since newly formed vessels are characterized by structural, functional and molecular abnormalities, they offer promising targets for tumor diagnosis and therapy. Previous studies indicate that MRI is valuable to assess vessel morphology and function. It can be used to distinguish between benign and malignant lesions and to improve delineation of proliferating areas within heterogeneous tumors. In addition, tracer kinetic analysis of contrast-enhanced image series allows the estimation of well-defined physiological parameters such as blood volume, blood flow and vessel permeability. Frequently, changes of these parameters during cytostatic, anti-angiogenic and radiation therapy precede tumor volume reduction. Moreover, target-specific MRI techniques can be used to elucidate the expression of angiogenic markers at the molecular level. This review summarizes strategies for non-invasive characterization of tumor vascularization by functional and molecular MRI, hereby introducing representative preclinical and clinical applications. (orig.)

  8. Gas dynamics considerations in a non-invasive profile monitor for charged particle beams

    CERN Document Server

    Tzoganis, Vasilis; Welsch, Carsten P

    2014-01-01

    A non-invasive, gas jet-based, beam profile monitor has been developed in the QUASAR Group at the Cockcroft Institute, UK. This allows on-line measurement of the 2-dimensional transverse profile of particle beams with negligible disturbance to either primary beam or accelerator vacuum. The monitor is suitable for use with beams across a wide range of energies and intensities. In this setup a nozzle-skimmer system shapes a thin supersonic gas jet into a curtain. However, the small dimensions of the gas inlet nozzle and subsequent skimmers were shown to be the cause of many operational problems. In this paper, the dynamics of gas jet formation transport and shaping is discussed before an image-processing based alignment technique is introduced. Furthermore, experimental results obtained with a 5 keV electron beam are discussed and the effects of gas stagnation pressure on the acquired beam are presented.

  9. In situ non-invasive EDXRF analysis to reconstruct stratigraphy and thickness of Renaissance pictorial multilayers

    International Nuclear Information System (INIS)

    Bonizzoni, L.; Poldi, G.; Milazzo, M.; Galli, A.

    2007-01-01

    In this paper, we report a few examples showing how energy dispersive XRF analysis (EDXRF) coupled with visible reflectance spectroscopy (vis-RS) can be successfully applied for the investigation of wood or canvas paintings by performing stratigraphic analyses with non-invasive techniques. The specific aim is to reconstruct layers and their thicknesses. The method has been tested in the laboratory on paint layers similar to traditional Renaissance ones. In situ analyses of a famous wood painting by Andrea Mantegna - 'Madonna col bambino e un coro di cherubini', Pinacoteca di Brera, Milan - were also carried out. While illustrating the results concerning the identification of pigments and the discrimination of layer stratigraphy, advantages and limitation of this method are pointed out. (authors)

  10. A non-invasive method for fractionated steriotactic irradiation of brain tumors with linear accelerator

    International Nuclear Information System (INIS)

    Hariz, M.I.; Laitinen, L.V.; Henriksson, R.; Saeterborg, N.-E.; Loefroth, P.-O.

    1990-01-01

    A new technique for fractionated stereotactic irradiation of intracranial lesions is described. The treatment is based on a versatile, non-invasive interface for stereotactic localization of the brain target imaged by computed tomography (CT), angiography or magnetic resonance tomography (MRT), and subsequent repetitive stereotactic irradiation of the target using a linear accelerator. The fractionation of the stereotactic irradiation was intended to meet the requirements of the basic principles of radiobiology. The radiophysical evaluation using phantoms, and the clinical results in a small number of patients, demonstrated a good reproducibilit between repeated positionings of the target in the isocenter of the accelerator, and a high degree of accuracy in the treatment of brain lesions. (authors). 28 refs.; 11 figs.; 1 tab

  11. Non-invasive imaging methods applied to neo- and paleo-ontological cephalopod research

    Science.gov (United States)

    Hoffmann, R.; Schultz, J. A.; Schellhorn, R.; Rybacki, E.; Keupp, H.; Gerden, S. R.; Lemanis, R.; Zachow, S.

    2014-05-01

    Several non-invasive methods are common practice in natural sciences today. Here we present how they can be applied and contribute to current topics in cephalopod (paleo-) biology. Different methods will be compared in terms of time necessary to acquire the data, amount of data, accuracy/resolution, minimum/maximum size of objects that can be studied, the degree of post-processing needed and availability. The main application of the methods is seen in morphometry and volumetry of cephalopod shells. In particular we present a method for precise buoyancy calculation. Therefore, cephalopod shells were scanned together with different reference bodies, an approach developed in medical sciences. It is necessary to know the volume of the reference bodies, which should have similar absorption properties like the object of interest. Exact volumes can be obtained from surface scanning. Depending on the dimensions of the study object different computed tomography techniques were applied.

  12. In vivo neuro MR spectroscopy: a non-invasive insight into cerebral metabolism

    International Nuclear Information System (INIS)

    Rose, S.; De Zubicaray, G.; Wang, D.; Galloway, G.; Doddrell, D.; Chalk, J.; University of Queensland, Brisbane, QLD; Eagle, S.; Semple, J.

    1999-01-01

    In addition to conventional magnetic resonance imaging (MRI) for examining anatomical structure, in vivo proton magnetic resonance spectroscopy (MRS) is currently being used as a non-invasive clinical tool for monitoring altered brain metabolism. Conditions such as head injury, dementia, multiple sclerosis, tumour, stroke, epilepsy and inborn errors of metabolism are all presently being investigated with MRS. At the Centre for Magnetic Resonance, we are currently undertaking a longitudinal study of dementia progression in Alzheimer's disease (AD) utilising both MRS and volumetric MRI techniques. The aim is to identify metabolic differences between this patient group and normal older adults and to correlate these measures with cognitive function. Cerebral artrophy, or loss of brain matter, together with ventricular enlargement , or enlargement of normally occuring cavities, is clearly present on MRI exams in patients with moderate and severe AD

  13. Non-invasive anesthesia for children undergoing proton radiation therapy

    International Nuclear Information System (INIS)

    Owusu-Agyemang, Pascal; Grosshans, David; Arunkumar, Radha; Rebello, Elizabeth; Popovich, Shannon; Zavala, Acsa; Williams, Cynthia; Ruiz, Javier; Hernandez, Mike; Mahajan, Anita; Porche, Vivian

    2014-01-01

    Background: Proton therapy is a newer modality of radiotherapy during which anesthesiologists face specific challenges related to the setup and duration of treatment sessions. Purpose: Describe our anesthesia practice for children treated in a standalone proton therapy center, and report on complications encountered during anesthesia. Materials and methods: A retrospective review of anesthetic records for patients ⩽18 years of age treated with proton therapy at our institution between January 2006 and April 2013 was performed. Results: A total of 9328 anesthetics were administered to 340 children with a median age of 3.6 years (range, 0.4–14.2). The median daily anesthesia time was 47 min (range, 15–79). The average time between start of anesthesia to the start of radiotherapy was 7.2 min (range, 1–83 min). All patients received Total Intravenous Anesthesia (TIVA) with spontaneous ventilation, with 96.7% receiving supplemental oxygen by non-invasive methods. None required daily endotracheal intubation. Two episodes of bradycardia, and one episode each of; seizure, laryngospasm and bronchospasm were identified for a cumulative incidence of 0.05%. Conclusions: In this large series of children undergoing proton therapy at a freestanding center, TIVA without daily endotracheal intubation provided a safe, efficient, and less invasive option of anesthetic care

  14. Non-invasive biosensor and wilreless interrogating system for hypoglycemia

    Science.gov (United States)

    Varadan, Vijay K.; Whitchurch, Ashwin K.; Saukesi, K.

    2002-11-01

    Hypoglycemia - abnormal decrease in blood sugar - is a major obstacle in the management of diabetes and prevention of long-term complications, and it may impose serious effects on the brain, including impairment of memory and other cognitive functions. This paper presents the development of a non-invasive sensor with miniaturized telemetry device in a wrist-watch for monitoring glucose concentration in blood. The sensor concept is based on optical chiralit of glucose level in the interstitial fluid. The wrist watch consists of a laser power source of the wavelength compatible with the glucose. A nanofilm with specific chirality is placed at the bottom of the watch. The light then passes through the film and illuminates a small area on the skin.It has been documented that there is certain concentration of sugar level is taken by the intertitial fluid from the blood stream and deposit a portion of it at the dead skin. The wrist-watch when in contact with the outer skin of the human will thus monitor the glucose concentration. A wireless monitoring system in the watch then downloads the data from the watch to a Palm or laptop computer.

  15. Alteration of political belief by non- invasive brain stimulation

    Directory of Open Access Journals (Sweden)

    Caroline eChawke

    2016-01-01

    Full Text Available People generally have imperfect introspective access to the mechanisms underlying their political beliefs, yet can confidently communicate the reasoning that goes into their decision making process. An innate desire for certainty and security in ones beliefs may play an important and somewhat automatic role in motivating the maintenance or rejection of partisan support. The aim of the current study was to clarify the role of the DLPFC in the alteration of political beliefs. Recent neuroimaging studies have focused on the association between the DLPFC (a region involved in the regulation of cognitive conflict and error feedback processing and reduced affiliation with opposing political candidates. As such, this study used a method of non- invasive brain simulation (tRNS to enhance activity of the bilateral DLPFC during the incorporation of political campaign information. These findings indicate a crucial role for this region in political belief formation. However, enhanced activation of DLPFC does not necessarily result in the specific rejection of political beliefs. In contrast to the hypothesis the results appear to indicate a significant increase in conservative values regardless of participant’s initial political orientation and the political campaign advertisement they were exposed to.

  16. Reducing proactive aggression through non-invasive brain stimulation

    Science.gov (United States)

    Schuhmann, Teresa; Lobbestael, Jill; Arntz, Arnoud; Brugman, Suzanne; Sack, Alexander T.

    2015-01-01

    Aggressive behavior poses a threat to human collaboration and social safety. It is of utmost importance to identify the functional mechanisms underlying aggression and to develop potential interventions capable of reducing dysfunctional aggressive behavior already at a brain level. We here experimentally shifted fronto-cortical asymmetry to manipulate the underlying motivational emotional states in both male and female participants while assessing the behavioral effects on proactive and reactive aggression. Thirty-two healthy volunteers received either anodal transcranial direct current stimulation to increase neural activity within right dorsolateral prefrontal cortex, or sham stimulation. Aggressive behavior was measured with the Taylor Aggression Paradigm. We revealed a general gender effect, showing that men displayed more behavioral aggression than women. After the induction of right fronto-hemispheric dominance, proactive aggression was reduced in men. This study demonstrates that non-invasive brain stimulation can reduce aggression in men. This is a relevant and promising step to better understand how cortical brain states connect to impulsive actions and to examine the causal role of the prefrontal cortex in aggression. Ultimately, such findings could help to examine whether the brain can be a direct target for potential supportive interventions in clinical settings dealing with overly aggressive patients and/or violent offenders. PMID:25680991

  17. Non-invasive Renal Denervation: Update on External Ultrasound Approaches.

    Science.gov (United States)

    Schmieder, Roland E; Ott, Christian; Bramlage, Peter

    2016-06-01

    In the last decade, intravenous renal denervation (RDN) has emerged as an alternative to pharmacological treatment in patients with resistant hypertension, but currently involves an invasive and technically challenging procedure. The Surround Sound™ system utilises externally delivered ultrasound to achieve RDN using a completely non-invasive, automated real-time tracking system coupled with a therapeutic delivery module thereby addressing these limitations. A brief history, technical overview and summary of preclinical and clinical studies of the KonaMedical Surround Sound™ system are presented. A literature search using the terms "renal denervation", "resistant hypertension" and "external ultrasound" was performed using PubMed, and references retrieved were selected based on relevancy and year of publication (date range 1991-2015). The Surround Sound™ system appears to be a promising approach to RDN which eliminates several of the factors currently limiting the intravenous approach. So far, it has demonstrated efficacy for reducing blood pressure in resistant hypertension patients with minimal adverse effects. Several double-blind, sham-controlled clinical trials are currently underway to confirm the validity of these findings.

  18. Non-invasive system for monitoring of the manufacturing equipment

    Science.gov (United States)

    Mazăre, A. G.; Belu, N.; Ionescu, L. M.; Rachieru, N.; Misztal, A.

    2017-08-01

    The automotive industry is one of the most important industries in the world that concerns the economy and the world culture. High demand has resulted in increasing of the pressure on the production lines. In conclusion, it is required more careful in monitoring of the production equipment not only for maintenance but also for staff safety and to increase the quality of production. In this paper, we propose a solution for non-invasive monitoring of the industrial equipment operation by measuring the current consumption on energy supply lines. Thus, it is determined the utilization schedule of the equipment and operation mode. Based on these measurements, it’s built an activity report for that equipment, available to the quality management and maintenance team. The solution consists of the current measuring equipment, with self-harvesting capabilities and radio transceiver, and an embedded system which run a server. The current measuring equipment will transmit data about consumption of each energy supply network line where is placed the industrial equipment. So, we have an internal measuring radio network. The embedded system will collect data for the equipment and put in a local data base and it will provide via an intranet application. The entire system not requires any supplementary energy supply and interventions in the factory infrastructure. It is experimented in a company from the automotive industries.

  19. Photoionization sensors for non-invasive medical diagnostics

    Science.gov (United States)

    Mustafaev, Aleksandr; Rastvorova, Iuliia; Khobnya, Kristina; Podenko, Sofia

    2016-09-01

    The analysis of biomarkers can help to identify the significant number of diseases: lung cancer, tuberculosis, diabetes, high levels of stress, psychosomatic disorders etc. To implement continuous monitoring of the state of human health, compact VUV photoionization detector with current-voltage measurement is designed by Saint-Petersburg Mining University Plasma Research Group. This sensor is based on the patented method of stabilization of electric parameters - CES (Collisional Electron Spectroscopy). During the operation at atmospheric pressure VUV photoionization sensor measures the energy of electrons, produced in the ionization with the resonance photons, whose wavelength situated in the vacuum ultraviolet (VUV). A special software was developed to obtain the second-order derivative of the I-U characteristics, taken by the VUV sensor, to construct the energy spectra of the characteristic electrons. VUV photoionization detector has an unique set of parameters: small size (10*10*1 mm), low cost, wide range of recognizable molecules, as well as accuracy, sufficient for using this instrument for the medical purposes. This device can be used for non-invasive medical diagnostics without compromising the quality of life, for control of environment and human life. Work supported by Foundation for Assistance to Small Innovative Enterprises in Science and Technology.

  20. Non-invasive ventilation in acute respiratory failure in children.

    Science.gov (United States)

    Abadesso, Clara; Nunes, Pedro; Silvestre, Catarina; Matias, Ester; Loureiro, Helena; Almeida, Helena

    2012-04-02

    The aim of this paper is to assess the clinical efficacy of non-invasive ventilation (NIV) in avoiding endotracheal intubation (ETI), to demonstrate clinical and gasometric improvement and to identify predictive risk factors associated with NIV failure. An observational prospective clinical study was carried out. Included Patients with acute respiratory disease (ARD) treated with NIV, from November 2006 to January 2010 in a Pediatric Intensive Care Unit (PICU). NIV was used in 151 patients with acute respiratory failure (ARF). Patients were divided in two groups: NIV success and NIV failure, if ETI was required. Mean age was 7.2±20.3 months (median: 1 min: 0,3 max.: 156). Main diagnoses were bronchiolitis in 102 (67.5%), and pneumonia in 44 (29%) patients. There was a significant improvement in respiratory rate (RR), heart rate (HR), pH, and pCO(2) at 2, 6, 12 and 24 hours after NIV onset (Papneia (P<0.001; odds ratio 15.8; 95% confidence interval: 3.42-71.4) and pneumonia (P<0.001, odds ratio 31.25; 95% confidence interval: 8.33-111.11). There were no major complications related with NIV. In conclusion this study demonstrates the efficacy of NIV as a form of respiratory support for children and infants with ARF, preventing clinical deterioration and avoiding ETI in most of the patients. Risk factors for failure were related with immaturity and severe infection.

  1. Facilitate insight by non-invasive brain stimulation.

    Directory of Open Access Journals (Sweden)

    Richard P Chi

    Full Text Available Our experiences can blind us. Once we have learned to solve problems by one method, we often have difficulties in generating solutions involving a different kind of insight. Yet there is evidence that people with brain lesions are sometimes more resistant to this so-called mental set effect. This inspired us to investigate whether the mental set effect can be reduced by non-invasive brain stimulation. 60 healthy right-handed participants were asked to take an insight problem solving task while receiving transcranial direct current stimulation (tDCS to the anterior temporal lobes (ATL. Only 20% of participants solved an insight problem with sham stimulation (control, whereas 3 times as many participants did so (p = 0.011 with cathodal stimulation (decreased excitability of the left ATL together with anodal stimulation (increased excitability of the right ATL. We found hemispheric differences in that a stimulation montage involving the opposite polarities did not facilitate performance. Our findings are consistent with the theory that inhibition to the left ATL can lead to a cognitive style that is less influenced by mental templates and that the right ATL may be associated with insight or novel meaning. Further studies including neurophysiological imaging are needed to elucidate the specific mechanisms leading to the enhancement.

  2. Non-Invasive Ocular Rigidity Measurement: A Differential Tonometry Approach

    Directory of Open Access Journals (Sweden)

    Efstathios T. Detorakis

    2015-12-01

    Full Text Available Purpose: Taking into account the fact that Goldmann applanation tonometry (GAT geometrically deforms the corneal apex and displaces volume from the anterior segment whereas Dynamic Contour Tonometry (DCT does not, we aimed at developing an algorithm for the calculation of ocular rigidity (OR based on the differences in pressure and volume between deformed and non-deformed status according to the general Friedenwald principle of differential tonometry. Methods: To avoid deviations of GAT IOP from true IOP in eyes with corneas different from the “calibration cornea” we applied the previously described Orssengo-Pye algorithm to calculate an error coefficient “C/B”. To test the feasibility of the proposed model, we calculated the OR coefficient (r in 17 cataract surgery candidates (9 males and 8 females. Results: The calculated r according to our model (mean ± SD, range was 0.0174 ± 0.010 (0.0123–0.022 mmHg/μL. A negative statistically significant correlation between axial length and r was detected whereas correlations between r and other biometric parameters examined were statistically not significant. Conclusions: The proposed method may prove a valid non-invasive tool for the measurement method of OR, which could help in introducing OR in the decision-making of the routine clinical practice.

  3. Alteration of Political Belief by Non-invasive Brain Stimulation

    Science.gov (United States)

    Chawke, Caroline; Kanai, Ryota

    2016-01-01

    People generally have imperfect introspective access to the mechanisms underlying their political beliefs, yet can confidently communicate the reasoning that goes into their decision making process. An innate desire for certainty and security in ones beliefs may play an important and somewhat automatic role in motivating the maintenance or rejection of partisan support. The aim of the current study was to clarify the role of the DLPFC in the alteration of political beliefs. Recent neuroimaging studies have focused on the association between the DLPFC (a region involved in the regulation of cognitive conflict and error feedback processing) and reduced affiliation with opposing political candidates. As such, this study used a method of non-invasive brain simulation (tRNS) to enhance activity of the bilateral DLPFC during the incorporation of political campaign information. These findings indicate a crucial role for this region in political belief formation. However, enhanced activation of DLPFC does not necessarily result in the specific rejection of political beliefs. In contrast to the hypothesis the results appear to indicate a significant increase in conservative values regardless of participant's initial political orientation and the political campaign advertisement they were exposed to. PMID:26834603

  4. Ultrasound cavitation versus cryolipolysis for non-invasive body contouring.

    Science.gov (United States)

    Mahmoud ELdesoky, Mohamed Taher; Mohamed Abutaleb, Enas ELsayed; Mohamed Mousa, Gihan Samir

    2015-08-24

    The demand for non-surgical and non-invasive devices is continuous and increasing. Such devices have gradually gained ground in the reduction of localised fat and the improvement of body contouring. The study aimed to compare the effects of ultrasound cavitation and cryolipolysis on localised abdominal fat. In total, 60 participants with a body mass index (BMI) over 30 kg/m 2 , whose age ranged between 25 and 45 years, were included. The participants were randomly assigned to three groups of 20 each, using ultrasound cavitation and diet, cryolipolysis and diet, and diet only (the control group), respectively. Measures were bodyweight, BMI, waist circumference and suprailiac skinfold were measured at the beginning of the study and 2 months later. The three groups showed significant improvements in all measured variables after 2 months. There was no statistically significant difference in bodyweight or in BMI among the groups after treatment. However, the groups using ultrasound cavitation and cryolipolysis showed better post-treatment improvement than the diet-only group in waist circumference and suprailiac skinfold. There was no statistically significant difference post-treatment between the cavitation and cryolipolysis groups in waist circumference or suprailiac skinfold. Both ultrasound cavitation and cryolipolysis are safe and effective for the reduction of abdominal fat thickness and for abdominal contouring. © 2015 The Australasian College of Dermatologists.

  5. Non-Invasive In Vivo Characterization of Breast Tumors Using Photon Migration Spectroscopy

    Directory of Open Access Journals (Sweden)

    Bruce J. Tromberg

    2000-01-01

    Full Text Available Frequency-domain photon migration (FDPM is a noninvasive optical technique that utilizes intensity-modulated, near-infrared (NIR light to quantitatively measure optical properties in thick tissues. Optical properties (absorption, μa, and scattering, μs′, parameters derived from FDPM measurements can be used to construct low-resolution (0.5 to 1 cm functional images of tissue hemoglobin (total, oxy-, and deoxyforms, oxygen saturation, blood volume fraction, water content, fat content and cellular structure. Unlike conventional NIR transillumination, FDPM enables quantitative analysis of tissue absorption and scattering parameters in a single non-invasive measurement. The unique functional information provided by FDPM makes it well-suited to characterizing tumors in thick tissues. In order to test the sensitivity of FDPM for cancer diagnosis, we have initiated clinical studies to quantitatively determine normal and malignant breast tissue optical and physiological properties in human subjects. Measurements are performed using a non-invasive, multi-wavelength, diode-laser FDPM device optimized for clinical studies. Results show that ductal carcinomas (invasive and in situ and benign fibroadenomas exhibit 1.25 to 3-fold higher absorption than normal breast tissue. Within this group, absorption is greatest for measurements obtained from sites of invasive cancer. Optical scattering is approximately 20% greater in pre-menopausal versus post-menopausal subjects due to differences in gland/cell proliferation and collagen/fat content. Spatial variations in tissue scattering reveal the loss of differentiation associated with breast disease progression. Overall, the metabolic demands of hormonal stimulation and tumor growth are detectable using photon migration techniques. Measurements provide quantitative optical property values that reflect changes in tissue perfusion, oxygen consumption, and cell/matrix development.

  6. A review of non-invasive imaging methods and applications in contaminant hydrogeology research.

    Science.gov (United States)

    Werth, Charles J; Zhang, Changyong; Brusseau, Mark L; Oostrom, Mart; Baumann, Thomas

    2010-04-01

    Contaminant hydrogeological processes occurring in porous media are typically not amenable to direct observation. As a result, indirect measurements (e.g., contaminant breakthrough at a fixed location) are often used to infer processes occurring at different scales, locations, or times. To overcome this limitation, non-invasive imaging methods are increasingly being used in contaminant hydrogeology research. Four of the most common methods, and the subjects of this review, are optical imaging using UV or visible light, dual-energy gamma radiation, X-ray microtomography, and magnetic resonance imaging (MRI). Non-invasive imaging techniques have provided valuable insights into a variety of complex systems and processes, including porous media characterization, multiphase fluid distribution, fluid flow, solute transport and mixing, colloidal transport and deposition, and reactions. In this paper we review the theory underlying these methods, applications of these methods to contaminant hydrogeology research, and methods' advantages and disadvantages. As expected, there is no perfect method or tool for non-invasive imaging. However, optical methods generally present the least expensive and easiest options for imaging fluid distribution, solute and fluid flow, colloid transport, and reactions in artificial two-dimensional (2D) porous media. Gamma radiation methods present the best opportunity for characterization of fluid distributions in 2D at the Darcy scale. X-ray methods present the highest resolution and flexibility for three-dimensional (3D) natural porous media characterization, and 3D characterization of fluid distributions in natural porous media. And MRI presents the best option for 3D characterization of fluid distribution, fluid flow, colloid transport, and reaction in artificial porous media. Obvious deficiencies ripe for method development are the ability to image transient processes such as fluid flow and colloid transport in natural porous media in three

  7. A New Quantitative Method for the Non-Invasive Documentation of Morphological Damage in Paintings Using RTI Surface Normals

    Directory of Open Access Journals (Sweden)

    Marcello Manfredi

    2014-07-01

    Full Text Available In this paper we propose a reliable surface imaging method for the non-invasive detection of morphological changes in paintings. Usually, the evaluation and quantification of changes and defects results mostly from an optical and subjective assessment, through the comparison of the previous and subsequent state of conservation and by means of condition reports. Using quantitative Reflectance Transformation Imaging (RTI we obtain detailed information on the geometry and morphology of the painting surface with a fast, precise and non-invasive method. Accurate and quantitative measurements of deterioration were acquired after the painting experienced artificial damage. Morphological changes were documented using normal vector images while the intensity map succeeded in highlighting, quantifying and describing the physical changes. We estimate that the technique can detect a morphological damage slightly smaller than 0.3 mm, which would be difficult to detect with the eye, considering the painting size. This non-invasive tool could be very useful, for example, to examine paintings and artwork before they travel on loan or during a restoration. The method lends itself to automated analysis of large images and datasets. Quantitative RTI thus eases the transition of extending human vision into the realm of measuring change over time.

  8. Non-invasive brain stimulation for the treatment of brain diseases in childhood and adolescence: state of the art, current limits and future challenges

    Directory of Open Access Journals (Sweden)

    Carmelo Mario Vicario

    2013-11-01

    Full Text Available In the last decades interest in application of non-invasive brain stimulation for enhancing neural functions is growing continuously. However, the use of such techniques in pediatric populations remains rather limited and mainly confined to the treatment of severe neurological and psychiatric diseases. In this article we provide a complete review of non-invasive brain stimulation studies conducted in pediatric populations. We also provide a brief discussion about the current limitations and future directions in a field of research still very young and full of issues to be explored.

  9. Non-invasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography.

    LENUS (Irish Health Repository)

    Weisz, Dany E

    2012-01-01

    Non-invasive cardiac output monitoring is a potentially useful clinical tool in the neonatal setting. Our aim was to evaluate a new method of non-invasive continuous cardiac output (CO) measurement (NICOM™) based on the principle of bioreactance in neonates.

  10. Advanced signal processing theory and implementation for sonar, radar, and non-invasive medical diagnostic systems

    CERN Document Server

    Stergiopoulos, Stergios

    2009-01-01

    Integrates topics of signal processing from sonar, radar, and medical system technologies by identifying their concept similarities. This book covers non-invasive medical diagnostic system applications, including intracranial ultrasound, a technology that attempts to address non-invasive detection on brain injuries and stroke.

  11. Markers for the non-invasive diagnosis of mesothelioma: a systematic review

    NARCIS (Netherlands)

    van der Bij, S.; Schaake, E.; Koffijberg, H.; Burgers, J. A.; de Mol, B. A. J. M.; Moons, K. G. M.

    2011-01-01

    BACKGROUND: Numerous markers have been evaluated to facilitate the non-invasive diagnostic work-up of mesothelioma. The purpose of this study was to conduct a structured review of the diagnostic performance of non-invasive marker tests for the detection of mesothelioma in patients with suspected

  12. Markers for the non-invasive diagnosis of mesothelioma : A systematic review

    NARCIS (Netherlands)

    van der Bij, S.; Schaake, E.; Koffijberg, H.; Burgers, J. A.; De Mol, B. A J M; Moons, K.G.M.

    2011-01-01

    Background: Numerous markers have been evaluated to facilitate the non-invasive diagnostic work-up of mesothelioma. The purpose of this study was to conduct a structured review of the diagnostic performance of non-invasive marker tests for the detection of mesothelioma in patients with suspected

  13. Non-invasive genetic monitoring of wild central chimpanzees.

    Directory of Open Access Journals (Sweden)

    Mimi Arandjelovic

    Full Text Available BACKGROUND: An assessment of population size and structure is an important first step in devising conservation and management plans for endangered species. Many threatened animals are elusive, rare and live in habitats that prohibit directly counting individuals. For example, a well-founded estimate of the number of great apes currently living in the wild is lacking. Developing methods to obtain accurate population estimates for these species is a priority for their conservation management. Genotyping non-invasively collected faecal samples is an effective way of evaluating a species' population size without disruption, and can also reveal details concerning population structure. METHODOLOGY/PRINCIPAL FINDINGS: We opportunistically collected wild chimpanzee faecal samples for genetic capture-recapture analyses over a four-year period in a 132 km(2 area of Loango National Park, Gabon. Of the 444 samples, 46% yielded sufficient quantities of DNA for genotyping analysis and the consequent identification of 121 individuals. Using genetic capture-recapture, we estimate that 283 chimpanzees (range: 208-316 inhabited the research area between February 2005 and July 2008. Since chimpanzee males are patrilocal and territorial, we genotyped samples from males using variable Y-chromosome microsatellite markers and could infer that seven chimpanzee groups are present in the area. Genetic information, in combination with field data, also suggested the occurrence of repeated cases of intergroup violence and a probable group extinction. CONCLUSIONS/SIGNIFICANCE: The poor amplification success rate resulted in a limited number of recaptures and hence only moderate precision (38%, measured as the entire width of the 95% confidence interval, but this was still similar to the best results obtained using intensive nest count surveys of apes (40% to 63%. Genetic capture-recapture methods applied to apes can provide a considerable amount of novel information on

  14. Smartphone based non-invasive salivary glucose biosensor.

    Science.gov (United States)

    Soni, Anuradha; Jha, Sandeep Kumar

    2017-12-15

    The present work deals with the development of a non-invasive optical glucose biosensor using saliva samples and a smartphone. The sensor was fabricated with a simple methodology by immobilization of Glucose oxidase enzyme along with a pH responsive dye on a filter paper based strip. The strip changes color upon reaction with glucose present in saliva and the color changes were detected using a smartphone camera through RGB profiling. This standalone biosensor showed good sensitivity and low interference while operating within 20 s response time. We used various means for improvements such as the use of slope method instead of differential response; use of a responsive pH indicator and made numerous tweaks in the smartphone app. Calibration with spiked saliva samples with slopes for (R + G + B) pixels revealed an exponentially increasing calibration curve with a linear detection range of 50-540 mg/dL, sensitivity of 0.0012 pixels sec -1 /mg dL -1 and LOD of 24.6 mg/dL. The biosensor was clinically validated on both healthy and diabetic subjects divided into several categories based on sex, age, diabetic status etc. and correlation between blood and salivary glucose has been established for better standardization of the sensor. Correlation of 0.44 was obtained between blood and salivary glucose in healthy individuals whereas it was 0.64 and 0.94 in case of prediabetic and diabetic patients respectively. The developed biosensor has the potential to be used for mass diagnosis of diabetes especially in such areas where people remain prohibited from routine analysis due to high healthcare cost. Apart from that, a smartphone would be the only device the user needs for this measurement, along with a disposable low cost test strip. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Skin Hydration Assessment through Modern Non-Invasive Bioengineering Technologies.

    Science.gov (United States)

    Constantin, Maria-Magdalena; Poenaru, Elena; Poenaru, Calin; Constantin, Traian

    2014-03-01

    Non-invasive bioengineering technologies continuously discovered and developed in recent decades provide a significant input to research development and remarkably contribute to the improvement of medical education and care to our patients. Assessing skin hydration by using the capacitance method for a group of patients with allergic contact dermatitis versus healthy subjects, before and after applying a moisturiser (assessing the immediate and long-term effectiveness of hydration). For both groups, but especially for the patients with dry skin, there was a clear improvement of hydration, statistically significant after applying the moisturiser. In the case of the patients with allergic contact dermatitis, hydration was at a maximum immediately after the first application, and then maintained an increased level after 7 and 28 days, respectively. In the healthy subjects, the increase in hydration was lower, but progressive. The moisturiser determined an increase in hydration for all age groups, but those who showed the most obvious effect were the young adults (18-29 years old) with an increase of 19.9%.The maintenance effect of hydration lasted for 28 days, while the improvement was important for allergic skin (17.1%) and significant for healthy skin (10.9%). The assessment of epidermal hydration performed by using the corneometer showed very good hydration of the stratum corneum for both groups studied, with immediate and long-term effect. This study also showed that the degree of skin hydration was inversely proportional with age. The corneometer is easy to use, efficient and widely utilised in international studies for measurements in healthy or pathological conditions, for quantitative assessment of the effectiveness of various preparations intended for application to the skin surface, under well-controlled and standardised conditions.

  16. Non-invasive Brain Stimulation: A Paradigm Shift in Understanding Brain Oscillations

    Directory of Open Access Journals (Sweden)

    Johannes Vosskuhl

    2018-05-01

    Full Text Available Cognitive neuroscience set out to understand the neural mechanisms underlying cognition. One central question is how oscillatory brain activity relates to cognitive processes. Up to now, most of the evidence supporting this relationship was correlative in nature. This situation changed dramatically with the recent development of non-invasive brain stimulation (NIBS techniques, which open up new vistas for neuroscience by allowing researchers for the first time to validate their correlational theories by manipulating brain functioning directly. In this review, we focus on transcranial alternating current stimulation (tACS, an electrical brain stimulation method that applies sinusoidal currents to the intact scalp of human individuals to directly interfere with ongoing brain oscillations. We outline how tACS can impact human brain oscillations by employing different levels of observation from non-invasive tACS application in healthy volunteers and intracranial recordings in patients to animal studies demonstrating the effectiveness of alternating electric fields on neurons in vitro and in vivo. These findings likely translate to humans as comparable effects can be observed in human and animal studies. Neural entrainment and plasticity are suggested to mediate the behavioral effects of tACS. Furthermore, we focus on mechanistic theories about the relationship between certain cognitive functions and specific parameters of brain oscillaitons such as its amplitude, frequency, phase and phase coherence. For each of these parameters we present the current state of testing its functional relevance by means of tACS. Recent developments in the field of tACS are outlined which include the stimulation with physiologically inspired non-sinusoidal waveforms, stimulation protocols which allow for the observation of online-effects, and closed loop applications of tACS.

  17. Conscious brain-to-brain communication in humans using non-invasive technologies.

    Science.gov (United States)

    Grau, Carles; Ginhoux, Romuald; Riera, Alejandro; Nguyen, Thanh Lam; Chauvat, Hubert; Berg, Michel; Amengual, Julià L; Pascual-Leone, Alvaro; Ruffini, Giulio

    2014-01-01

    Human sensory and motor systems provide the natural means for the exchange of information between individuals, and, hence, the basis for human civilization. The recent development of brain-computer interfaces (BCI) has provided an important element for the creation of brain-to-brain communication systems, and precise brain stimulation techniques are now available for the realization of non-invasive computer-brain interfaces (CBI). These technologies, BCI and CBI, can be combined to realize the vision of non-invasive, computer-mediated brain-to-brain (B2B) communication between subjects (hyperinteraction). Here we demonstrate the conscious transmission of information between human brains through the intact scalp and without intervention of motor or peripheral sensory systems. Pseudo-random binary streams encoding words were transmitted between the minds of emitter and receiver subjects separated by great distances, representing the realization of the first human brain-to-brain interface. In a series of experiments, we established internet-mediated B2B communication by combining a BCI based on voluntary motor imagery-controlled electroencephalographic (EEG) changes with a CBI inducing the conscious perception of phosphenes (light flashes) through neuronavigated, robotized transcranial magnetic stimulation (TMS), with special care taken to block sensory (tactile, visual or auditory) cues. Our results provide a critical proof-of-principle demonstration for the development of conscious B2B communication technologies. More fully developed, related implementations will open new research venues in cognitive, social and clinical neuroscience and the scientific study of consciousness. We envision that hyperinteraction technologies will eventually have a profound impact on the social structure of our civilization and raise important ethical issues.

  18. Conscious brain-to-brain communication in humans using non-invasive technologies.

    Directory of Open Access Journals (Sweden)

    Carles Grau

    Full Text Available Human sensory and motor systems provide the natural means for the exchange of information between individuals, and, hence, the basis for human civilization. The recent development of brain-computer interfaces (BCI has provided an important element for the creation of brain-to-brain communication systems, and precise brain stimulation techniques are now available for the realization of non-invasive computer-brain interfaces (CBI. These technologies, BCI and CBI, can be combined to realize the vision of non-invasive, computer-mediated brain-to-brain (B2B communication between subjects (hyperinteraction. Here we demonstrate the conscious transmission of information between human brains through the intact scalp and without intervention of motor or peripheral sensory systems. Pseudo-random binary streams encoding words were transmitted between the minds of emitter and receiver subjects separated by great distances, representing the realization of the first human brain-to-brain interface. In a series of experiments, we established internet-mediated B2B communication by combining a BCI based on voluntary motor imagery-controlled electroencephalographic (EEG changes with a CBI inducing the conscious perception of phosphenes (light flashes through neuronavigated, robotized transcranial magnetic stimulation (TMS, with special care taken to block sensory (tactile, visual or auditory cues. Our results provide a critical proof-of-principle demonstration for the development of conscious B2B communication technologies. More fully developed, related implementations will open new research venues in cognitive, social and clinical neuroscience and the scientific study of consciousness. We envision that hyperinteraction technologies will eventually have a profound impact on the social structure of our civilization and raise important ethical issues.

  19. 1H NMR- based metabolomics approaches as non- invasive tools for diagnosis of endometriosis

    Directory of Open Access Journals (Sweden)

    Negar Ghazi

    2016-01-01

    Full Text Available Background: So far, non-invasive diagnostic approaches such as ultrasound, magnetic resonance imaging, or blood tests do not have sufficient diagnostic power for endometriosis disease. Lack of a non-invasive diagnostic test contributes to the long delay between onset of symptoms and diagnosis of endometriosis. Objective: The present study focuses on the identification of predictive biomarkers in serum by pattern recognition techniques and uses partial least square discriminant analysis, multi-layer feed forward artificial neural networks (ANNs and quadratic discriminant analysis (QDA modeling tools for the early diagnosis of endometriosis in a minimally invasive manner by 1H- NMR based metabolomics. Materials and Methods: This prospective cohort study was done in Pasteur Institute, Iran in June 2013. Serum samples of 31 infertile women with endometriosis (stage II and III who confirmed by diagnostic laparoscopy and 15 normal women were collected and analyzed by nuclear magnetic resonance spectroscopy. The model was built by using partial least square discriminant analysis, QDA, and ANNs to determine classifier metabolites for early prediction risk of disease. Results: The levels of 2- methoxyestron, 2-methoxy estradiol, dehydroepiandrostion androstendione, aldosterone, and deoxy corticosterone were enhanced significantly in infertile group. While cholesterol and primary bile acids levels were decreased. QDA model showed significant difference between two study groups. Positive and negative predict value levels obtained about 71% and 78%, respectively. ANNs provided also criteria for detection of endometriosis. Conclusion: The QDA and ANNs modeling can be used as computational tools in noninvasive diagnose of endometriosis. However, the model designed by QDA methods is more efficient compared to ANNs in diagnosis of endometriosis patients.

  20. NON-INVASIVE RADIOFREQUENCY ABLATION OF CANCER TARGETED BY GOLD NANOPARTICLES

    Science.gov (United States)

    Cardinal, Jon; Klune, John Robert; Chory, Eamon; Jeyabalan, Geetha; Kanzius, John S.; Nalesnik, Michael; Geller, David A.

    2008-01-01

    Introduction Current radiofrequency ablation (RFA) techniques require invasive needle placement and are limited by accuracy of targeting. The purpose of this study was to test a novel non-invasive radiowave machine that uses RF energy to thermally destroy tissue. Gold nanoparticles were designed and produced to facilitate tissue heating by the radiowaves. Methods A solid state radiowave machine consisting of a power generator and transmitting/receiving couplers which transmit radiowaves at 13.56 MHz was used. Gold nanoparticles were produced by citrate reduction and exposed to the RF field either in solutions testing or after incubation with HepG2 cells. A rat hepatoma model using JM-1 cells and Fisher rats was employed using direct injection of nanoparticles into the tumor to focus the radiowaves for select heating. Temperatures were measured using a fiber-optic thermometer for real-time data. Results Solutions containing gold nanoparticles heated in a time- and power-dependent manner. HepG2 liver cancer cells cultured in the presence of gold nanoparticles achieved adequate heating to cause cell death upon exposure to the RF field with no cytotoxicity attributable to the gold nanoparticles themselves. In vivo rat exposures at 35W using gold nanoparticles for tissue injection resulted in significant temperature increases and thermal injury at subcutaneous injection sites as compared to vehicle (water) injected controls. Discussion These data show that non-invasive radiowave thermal ablation of cancer cells is feasible when facilitated by gold nanoparticles. Future studies will focus on tumor selective targeting of nanoparticles for in vivo tumor destruction. PMID:18656617

  1. UWB based low-cost and non-invasive practical breast cancer early detection

    Science.gov (United States)

    Vijayasarveswari, V.; Khatun, S.; Fakir, M. M.; Jusoh, M.; Ali, S.

    2017-03-01

    Breast cancer is one of the main causes of women death worldwide. Breast tumor is an early stage of cancer that locates in cells of a human breast. As there is no remedy, early detection is crucial. Towards this, Ultra-Wideband (UWB) is a prominent candidate. It is a wireless communication technology which can achieve high bandwidth with low power utilization. UWB is suitable to be used for short range communication systems including breast cancer detection since it is secure, non-invasive and human health friendly. This paper presents the low-cost and non-invasive early breast cancer detection strategy using UWB sensor (or antenna). Emphasis is given here to detect breast tumor in 2D and 3D environments. The developed system consisted of hardware and software. Hardware included UWB transceiver and a pair of home-made directional sensor/antenna. The software included feed-forward back propagation Neural Network (NN) module to detect the tumor existence, size and location along with soft interface between software and hardware. Forward scattering technique was used by placing two sensors diagonally opposite sides of a breast phantom. UWB pulses were transmitted from one side of phantom and received from other side, controlled by the software interface in PC environment. Collected received signals were then fed into the NN module for training, testing and validation. The system exhibited detection efficiency on tumor existence, location (x, y, z), and size were approximately 100%, (78.17%, 70.66%, 92.46%), 85.86% respectively. The proposed UWB based early breast cancer detection system could be more practical with low-cost, user friendly and non-harmful features. This project may help users to monitor their breast health regularly at their home.

  2. A non-invasive, quantitative study of broadband spectral responses in human visual cortex.

    Directory of Open Access Journals (Sweden)

    Eline R Kupers

    Full Text Available Currently, non-invasive methods for studying the human brain do not routinely and reliably measure spike-rate-dependent signals, independent of responses such as hemodynamic coupling (fMRI and subthreshold neuronal synchrony (oscillations and event-related potentials. In contrast, invasive methods-microelectrode recordings and electrocorticography (ECoG-have recently measured broadband power elevation in field potentials (~50-200 Hz as a proxy for locally averaged spike rates. Here, we sought to detect and quantify stimulus-related broadband responses using magnetoencephalography (MEG. Extracranial measurements like MEG and EEG have multiple global noise sources and relatively low signal-to-noise ratios; moreover high frequency artifacts from eye movements can be confounded with stimulus design and mistaken for signals originating from brain activity. For these reasons, we developed an automated denoising technique that helps reveal the broadband signal of interest. Subjects viewed 12-Hz contrast-reversing patterns in the left, right, or bilateral visual field. Sensor time series were separated into evoked (12-Hz amplitude and broadband components (60-150 Hz. In all subjects, denoised broadband responses were reliably measured in sensors over occipital cortex, even in trials without microsaccades. The broadband pattern was stimulus-dependent, with greater power contralateral to the stimulus. Because we obtain reliable broadband estimates with short experiments (~20 minutes, and with sufficient signal-to-noise to distinguish responses to different stimuli, we conclude that MEG broadband signals, denoised with our method, offer a practical, non-invasive means for characterizing spike-rate-dependent neural activity for addressing scientific questions about human brain function.

  3. Development of microsatellite markers and a restriction endonuclease digest assay for non-invasive sampling of endangered white-rumped, slender-billed and red-headed vultues

    Science.gov (United States)

    Y.A. Kapetanakos; I.J. Lovette; T.E. Katzner

    2014-01-01

    Southeast Asian vultures have been greatly reduced in range and population numbers, but it is challenging to use traditional tagging and monitoring techniques to track changes in their populations. Genotypes derived from non-invasively collected feather samples provide an alternative and effective means to 'capture' individual vultures for mark-recapture...

  4. Image-assisted non-invasive and dynamic biomechanical analysis of human joints

    International Nuclear Information System (INIS)

    Muhit, Abdullah A; Pickering, Mark R; Scarvell, Jennifer M; Ward, Tom; Smith, Paul N

    2013-01-01

    Kinematic analysis provides a strong link between musculoskeletal injuries, chronic joint conditions, treatment planning/monitoring and prosthesis design/outcome. However, fast and accurate 3D kinematic analysis still remains a challenge in order to translate this procedure into clinical scenarios. 3D computed tomography (CT) to 2D single-plane fluoroscopy registration is a promising non-invasive technology for biomechanical examination of human joints. Although this technique has proven to be very precise in terms of in-plane translation and rotation measurements, out-of-plane motion estimations have been a difficulty so far. Therefore, to enable this technology into clinical translation, precise and fast estimation of both in-plane and out-of-plane movements is crucial, which is the aim of this paper. Here, a fast and accurate 3D/2D registration technique is proposed to evaluate biomechanical/kinematic analysis. The proposed algorithm utilizes a new multi-modal similarity measure called ‘sum of conditional variances’, a coarse-to-fine Laplacian of Gaussian filtering approach for robust gradient-descent optimization and a novel technique for the analytic calculation of the required gradients for out-of-plane rotations. Computer simulations and in vitro experiments showed that the new approach was robust in terms of the capture range, required significantly less iterations to converge and achieved good registration and kinematic accuracy when compared to existing techniques and to the ‘gold-standard’ Roentgen stereo analysis. (paper)

  5. Pulmonary infiltrates in non-HIV immunocompromised patients: a diagnostic approach using non-invasive and bronchoscopic procedures

    Science.gov (United States)

    Rano, A; Agusti, C; Jimenez, P; Angrill, J; Benito, N; Danes, C; Gonzalez, J; Rovira, M; Pumarola, T; Moreno, A; Torres, A

    2001-01-01

    BACKGROUND—The development of pulmonary infiltrates is a frequent life threatening complication in immunocompromised patients, requiring early diagnosis and specific treatment. In the present study non-invasive and bronchoscopic diagnostic techniques were applied in patients with different non-HIV immunocompromised conditions to determine the aetiology of the pulmonary infiltrates and to evaluate the impact of these methods on therapeutic decisions and outcome in this population.
METHODS—The non-invasive diagnostic methods included serological tests, blood antigen detection, and blood, nasopharyngeal wash (NPW), sputum and tracheobronchial aspirate (TBAS) cultures. Bronchoscopic techniques included fibrobronchial aspirate (FBAS), protected specimen brush (PSB), and bronchoalveolar lavage (BAL). Two hundred consecutive episodes of pulmonary infiltrates were prospectively evaluated during a 30 month period in 52 solid organ transplant recipients, 53 haematopoietic stem cell transplant (HSCT) recipients, 68 patients with haematological malignancies, and 27 patients requiring chronic treatment with corticosteroids and/or immunosuppressive drugs.
RESULTS—An aetiological diagnosis was obtained in 162 (81%) of the 200 patients. The aetiology of the pulmonary infiltrates was infectious in 125 (77%) and non-infectious in 37 (23%); 38 (19%) remained undiagnosed. The main infectious aetiologies were bacterial (48/125, 24%), fungal (33/125, 17%), and viral (20/125, 10%), and the most frequent pathogens were Aspergillus fumigatus (n=29), Staphylococcus aureus (n=17), and Pseudomonas aeruginosa (n=12). Among the non-infectious aetiologies, pulmonary oedema (16/37, 43%) and diffuse alveolar haemorrhage (10/37, 27%) were the most common causes. Non-invasive techniques led to the diagnosis of pulmonary infiltrates in 41% of the cases in which they were used; specifically, the diagnostic yield of blood cultures was 30/191 (16%); sputum cultures 27/88 (31%); NPW 9/50 (18

  6. Endometrial biomarkers for the non-invasive diagnosis of endometriosis.

    Science.gov (United States)

    Gupta, Devashana; Hull, M Louise; Fraser, Ian; Miller, Laura; Bossuyt, Patrick M M; Johnson, Neil; Nisenblat, Vicki

    2016-04-20

    About 10% of reproductive-aged women suffer from endometriosis, which is a costly, chronic disease that causes pelvic pain and subfertility. Laparoscopy is the gold standard diagnostic test for endometriosis, but it is expensive and carries surgical risks. Currently, there are no non-invasive tests available in clinical practice that accurately diagnose endometriosis. This is the first diagnostic test accuracy review of endometrial biomarkers for endometriosis that utilises Cochrane methodologies, providing an update on the rapidly expanding literature in this field. To determine the diagnostic accuracy of the endometrial biomarkers for pelvic endometriosis, using a surgical diagnosis as the reference standard. We evaluated the tests as replacement tests for diagnostic surgery and as triage tests to inform decisions to undertake surgery for endometriosis. We did not restrict the searches to particular study designs, language or publication dates. To identify trials, we searched the following databases: CENTRAL (2015, July), MEDLINE (inception to May 2015), EMBASE (inception to May 2015), CINAHL (inception to April 2015), PsycINFO (inception to April 2015), Web of Science (inception to April 2015), LILACS (inception to April 2015), OAIster (inception to April 2015), TRIP (inception to April 2015) and ClinicalTrials.gov (inception to April 2015). We searched DARE and PubMed databases up to April 2015 to identify reviews and guidelines as sources of references to potentially relevant studies. We also performed searches for papers recently published and not yet indexed in the major databases. The search strategies incorporated words in the title, abstract, text words across the record and the medical subject headings (MeSH). We considered published peer-reviewed, randomised controlled or cross-sectional studies of any size that included prospectively collected samples from any population of reproductive-aged women suspected of having one or more of the following target

  7. Non-invasive brain stimulation: an interventional tool for enhancing behavioral training after stroke

    Directory of Open Access Journals (Sweden)

    Maximilian Jonas Wessel

    2015-05-01

    Full Text Available Stroke is the leading cause of disability among adults. Motor deficit is the most common impairment after stroke. Especially, deficits in fine motor skills impair numerous activities of daily life. Re-acquisition of motor skills resulting in improved or more accurate motor performance is paramount to regain function, and is the basis of behavioral motor therapy after stroke. Within the past years, there has been a rapid technological and methodological development in neuroimaging leading to a significant progress in the understanding of the neural substrates that underlie motor skill acquisition and functional recovery in stroke patients. Based on this and the development of novel non-invasive brain stimulation techniques, new adjuvant interventional approaches that augment the response to behavioral training have been proposed. Transcranial direct current (tDCS, transcranial magnetic (TMS and paired associative (PAS stimulation are noninvasive brain stimulation techniques that can modulate cortical excitability, neuronal plasticity and interact with learning and memory in both healthy individuals and stroke patients. These techniques can enhance the effect of practice and facilitate the retention of tasks that mimic daily life activities. The purpose of the present review is to provide a comprehensive overview of neuroplastic phenomena in the motor system during learning of a motor skill, recovery after brain injury, and of interventional strategies to enhance the beneficial effects of customarily used neurorehabilitation after stroke.

  8. Non-invasive brain stimulation of the aging brain: State of the art and future perspectives.

    Science.gov (United States)

    Tatti, Elisa; Rossi, Simone; Innocenti, Iglis; Rossi, Alessandro; Santarnecchi, Emiliano

    2016-08-01

    Favored by increased life expectancy and reduced birth rate, worldwide demography is rapidly shifting to older ages. The golden age of aging is not only an achievement but also a big challenge because of the load of the elderly on social and medical health care systems. Moreover, the impact of age-related decline of attention, memory, reasoning and executive functions on self-sufficiency emphasizes the need of interventions to maintain cognitive abilities at a useful degree in old age. Recently, neuroscientific research explored the chance to apply Non-Invasive Brain Stimulation (NiBS) techniques (as transcranial electrical and magnetic stimulation) to healthy aging population to preserve or enhance physiologically-declining cognitive functions. The present review will update and address the current state of the art on NiBS in healthy aging. Feasibility of NiBS techniques will be discussed in light of recent neuroimaging (either structural or functional) and neurophysiological models proposed to explain neural substrates of the physiologically aging brain. Further, the chance to design multidisciplinary interventions to maximize the efficacy of NiBS techniques will be introduced as a necessary future direction. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Using Non-Invasive Multi-Spectral Imaging to Quantitatively Assess Tissue Vasculature

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, A; Chernomordik, V; Riley, J; Hassan, M; Amyot, F; Dasgeb, B; Demos, S G; Pursley, R; Little, R; Yarchoan, R; Tao, Y; Gandjbakhche, A H

    2007-10-04

    This research describes a non-invasive, non-contact method used to quantitatively analyze the functional characteristics of tissue. Multi-spectral images collected at several near-infrared wavelengths are input into a mathematical optical skin model that considers the contributions from different analytes in the epidermis and dermis skin layers. Through a reconstruction algorithm, we can quantify the percent of blood in a given area of tissue and the fraction of that blood that is oxygenated. Imaging normal tissue confirms previously reported values for the percent of blood in tissue and the percent of blood that is oxygenated in tissue and surrounding vasculature, for the normal state and when ischemia is induced. This methodology has been applied to assess vascular Kaposi's sarcoma lesions and the surrounding tissue before and during experimental therapies. The multi-spectral imaging technique has been combined with laser Doppler imaging to gain additional information. Results indicate that these techniques are able to provide quantitative and functional information about tissue changes during experimental drug therapy and investigate progression of disease before changes are visibly apparent, suggesting a potential for them to be used as complementary imaging techniques to clinical assessment.

  10. Non-invasive brain stimulation: an interventional tool for enhancing behavioral training after stroke.

    Science.gov (United States)

    Wessel, Maximilian J; Zimerman, Máximo; Hummel, Friedhelm C

    2015-01-01

    Stroke is the leading cause of disability among adults. Motor deficit is the most common impairment after stroke. Especially, deficits in fine motor skills impair numerous activities of daily life. Re-acquisition of motor skills resulting in improved or more accurate motor performance is paramount to regain function, and is the basis of behavioral motor therapy after stroke. Within the past years, there has been a rapid technological and methodological development in neuroimaging leading to a significant progress in the understanding of the neural substrates that underlie motor skill acquisition and functional recovery in stroke patients. Based on this and the development of novel non-invasive brain stimulation (NIBS) techniques, new adjuvant interventional approaches that augment the response to behavioral training have been proposed. Transcranial direct current, transcranial magnetic, and paired associative (PAS) stimulation are NIBS techniques that can modulate cortical excitability, neuronal plasticity and interact with learning and memory in both healthy individuals and stroke patients. These techniques can enhance the effect of practice and facilitate the retention of tasks that mimic daily life activities. The purpose of the present review is to provide a comprehensive overview of neuroplastic phenomena in the motor system during learning of a motor skill, recovery after brain injury, and of interventional strategies to enhance the beneficial effects of customarily used neurorehabilitation after stroke.

  11. Exploration of Hand Grasp Patterns Elicitable Through Non-Invasive Proximal Nerve Stimulation.

    Science.gov (United States)

    Shin, Henry; Watkins, Zach; Hu, Xiaogang

    2017-11-29

    Various neurological conditions, such as stroke or spinal cord injury, result in an impaired control of the hand. One method of restoring this impairment is through functional electrical stimulation (FES). However, traditional FES techniques often lead to quick fatigue and unnatural ballistic movements. In this study, we sought to explore the capabilities of a non-invasive proximal nerve stimulation technique in eliciting various hand grasp patterns. The ulnar and median nerves proximal to the elbow joint were activated transcutanously using a programmable stimulator, and the resultant finger flexion joint angles were recorded using a motion capture system. The individual finger motions averaged across the three joints were analyzed using a cluster analysis, in order to classify the different hand grasp patterns. With low current intensity (grasp patterns including single finger movement and coordinated multi-finger movements. This study provides initial evidence on the feasibility of a proximal nerve stimulation technique in controlling a variety of finger movements and grasp patterns. Our approach could also be developed into a rehabilitative/assistive tool that can result in flexible movements of the fingers.

  12. Non-invasive diagnosis in cerebral ischemia by means of magnetic resonance imaging and near-infrared spectroscopy

    International Nuclear Information System (INIS)

    Piepgras, A.; Gueckel, F.; Laemmler, B.; Weigel, R.; Schmiedek, P.

    1994-01-01

    We describe the non-invasive assessment of cerebrovascular reserve capacity by means of near-infrared spectroscopy (NIRS) and magnetic resonance imaging. Both methods are compared with transcranial Doppler sonography. There is a good correlation of the three methods in the changes in cerebral oxygen saturation and in blood velocity following acetazolamide stimulation of cerebral blood flow, except found in one patient with unilateral carotid artery occlusion. In this patient we found a decreased cerebrovascular reserve capacity, revealed by a magnetic resonance technique designed to quantify CBV and CBF. We postulate a raised oxygen extraction as raised oxygen extraction as the cause of his changes in oxygen saturation. (orig.) [de

  13. Non-invasive tissue oximetry following unilateral DIEP-flap reconstruction: A pilot evaluation

    Directory of Open Access Journals (Sweden)

    N.P.A. Vranken

    2017-06-01

    Conclusion: Continuous non-invasive tissue oxygen saturation is suitable for postoperative monitoring of DIEP-flaps, and StO2 pattern may aid in early identification of vascular compromise in DIEP-flaps.

  14. Detrusor wall thickness compared to other non-invasive methods in ...

    African Journals Online (AJOL)

    W. ElSaied

    invasive tests. Abbreviations: ... obstruction, non-invasively in men with lower urinary tract symptoms, with an accuracy approaching that ..... gies such as infection or tumor [15]. .... diagnosis of infravesical obstruction in children: evaluation of blad-.

  15. In-situ Non-Invasive Imaging of Liquid-Immersed Thin Film Composite Membranes

    KAUST Repository

    Ogieglo, Wojciech; Pinnau, Ingo; Wessling, Matthias

    2017-01-01

    We present a non-invasive method to directly image liquid-immersed thin film composite membranes. The approach allows accessing information not only on the lateral distribution of the coating thickness, including variations in its swelling

  16. Non-invasive pre-clinical MR imaging of prostate tumor hypoxia for radiation therapy prognosis

    Directory of Open Access Journals (Sweden)

    Derek White

    2014-03-01

    Full Text Available Purpose: To investigate the usefulness of Oxygen-Enhanced Magnetic Resonance Imaging (OE-MRI changes in signal intensity related to oxygen challenge for predicting tumor response to radiation therapy.Methods: Dynamic MR signal changes were acquired using Varian 4.7T small animal MR scanner prior to image-guided radiation therapy (IGRT of small (n = 6 and large subcutaneous (n = 5 prostate tumors in adult male rats. An interleaved blood-oxygen level dependent (BOLD and tissue-oxygen level dependent (TOLD data acquisition or (IBT was performed using a baseline of medical air as positive control and using medical oxygen as a breathing challenge. BOLD used a 2-D multi-slice spoiled gradient-echo with multi-echo sequence. TOLD used a 2-D multi-slice spoiled gradient-echo sequence. Voxel changes in signal intensity were determined by a correlation coefficient mapping technique. Irradiation technique planned consisted of 1F × 15 Gy AP/PA or 2F × 7.5 Gy AP/PA to the gross tumor volume (GTV. Tumor growth measurements were recorded over time to assess the response to IGRT.Results: BOLD and TOLD signals variously illustrated positive or negative impulse responses in the tumor ROI due to inhaling medical oxygen. Correlation coefficient mapping demonstrated heterogeneity in tumors after inhaling medical oxygen. BOLD and TOLD signals exhibited increased changes in signal intensities after the first fraction of dose. Multi-fractionation had minimum effect until the second fraction of dose was applied. Tumor growth delays were observed when inhaling medical oxygen during IGRT.Conclusion: OE-MRI is a non-invasive imaging modality that can provide insight to the oxygen status of tumors. Observed increase percent changes in BOLD and TOLD signal intensities after the first fraction of dose suggest tumors experienced reoxygenation. OE-MRI could be used for predicting tumor response to IGRT when using medical oxygen for increasing GTV radiosensitivity, suggesting

  17. Using non-invasive brain stimulation to augment motor training-induced plasticity

    Directory of Open Access Journals (Sweden)

    Pascual-Leone Alvaro

    2009-03-01

    Full Text Available Abstract Therapies for motor recovery after stroke or traumatic brain injury are still not satisfactory. To date the best approach seems to be the intensive physical therapy. However the results are limited and functional gains are often minimal. The goal of motor training is to minimize functional disability and optimize functional motor recovery. This is thought to be achieved by modulation of plastic changes in the brain. Therefore, adjunct interventions that can augment the response of the motor system to the behavioural training might be useful to enhance the therapy-induced recovery in neurological populations. In this context, noninvasive brain stimulation appears to be an interesting option as an add-on intervention to standard physical therapies. Two non-invasive methods of inducing electrical currents into the brain have proved to be promising for inducing long-lasting plastic changes in motor systems: transcranial magnetic stimulation (TMS and transcranial direct current stimulation (tDCS. These techniques represent powerful methods for priming cortical excitability for a subsequent motor task, demand, or stimulation. Thus, their mutual use can optimize the plastic changes induced by motor practice, leading to more remarkable and outlasting clinical gains in rehabilitation. In this review we discuss how these techniques can enhance the effects of a behavioural intervention and the clinical evidence to date.

  18. L-cysteine capped lanthanum hydroxide nanostructures for non-invasive detection of oral cancer biomarker.

    Science.gov (United States)

    Tiwari, Sachchidanand; Gupta, Pramod K; Bagbi, Yana; Sarkar, Tamal; Solanki, Pratima R

    2017-03-15

    In this paper, we present the result of studies related to the in situ synthesis of amino acid (L-Cysteine) capped lanthanum hydroxide nanoparticles [Cys-La(OH) 3 NPs] towards the fabrication of efficient immunosensor for non-invasive detection of oral cancer. The characterization of Cys-La(OH) 3 NPs was carried out by different techniques including X-ray diffraction, scanning electron microscopy, transmission electron microscopy, fourier transform infrared spectroscopy and electrochemical techniques. These Cys-La(OH) 3 NPs were electrophoretically deposited onto an indium-tin-oxide glass substrate and used for immobilization of anti-cytokeratin fragment-21-1 (anti-Cyfra-21-1) for the electrochemical detection of Cyfra-21-1. This immunosensor shows a broad detection range of 0.001-10.2ngmL -1 , the low detection limit of 0.001ngmL -1 , and high sensitivity of 12.044µA (ng per mL cm -2 ) -1 with a response time of 5min. This immunosensor was found to be more advanced in terms of high sensitivity and low detection limit as compared to previously reported biosensors and commercially available ELISA kit (Kinesis DX). Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Combining non-invasive transcranial brain stimulation with neuroimaging and electrophysiology: Current approaches and future perspectives.

    Science.gov (United States)

    Bergmann, Til Ole; Karabanov, Anke; Hartwigsen, Gesa; Thielscher, Axel; Siebner, Hartwig Roman

    2016-10-15

    Non-invasive transcranial brain stimulation (NTBS) techniques such as transcranial magnetic stimulation (TMS) and transcranial current stimulation (TCS) are important tools in human systems and cognitive neuroscience because they are able to reveal the relevance of certain brain structures or neuronal activity patterns for a given brain function. It is nowadays feasible to combine NTBS, either consecutively or concurrently, with a variety of neuroimaging and electrophysiological techniques. Here we discuss what kind of information can be gained from combined approaches, which often are technically demanding. We argue that the benefit from this combination is twofold. Firstly, neuroimaging and electrophysiology can inform subsequent NTBS, providing the required information to optimize where, when, and how to stimulate the brain. Information can be achieved both before and during the NTBS experiment, requiring consecutive and concurrent applications, respectively. Secondly, neuroimaging and electrophysiology can provide the readout for neural changes induced by NTBS. Again, using either concurrent or consecutive applications, both "online" NTBS effects immediately following the stimulation and "offline" NTBS effects outlasting plasticity-inducing NTBS protocols can be assessed. Finally, both strategies can be combined to close the loop between measuring and modulating brain activity by means of closed-loop brain state-dependent NTBS. In this paper, we will provide a conceptual framework, emphasizing principal strategies and highlighting promising future directions to exploit the benefits of combining NTBS with neuroimaging or electrophysiology. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  20. Chemical Sensor Platform for Non-Invasive Monitoring of Activity and Dehydration

    Directory of Open Access Journals (Sweden)

    Dmitry Solovei

    2015-01-01

    Full Text Available A non-invasive solution for monitoring of the activity and dehydration of organisms is proposed in the work. For this purpose, a wireless standalone chemical sensor platform using two separate measurement techniques has been developed. The first approach for activity monitoring is based on humidity measurement. Our solution uses new humidity sensor based on a nanostructured TiO2 surface for sweat rate monitoring. The second technique is based on monitoring of potassium concentration in urine. High level of potassium concentration denotes clear occurrence of dehydration. Furthermore, a Wireless Body Area Network (WBAN was developed for this sensor platform to manage data transfer among devices and the internet. The WBAN coordinator controls the sensor devices and collects and stores the measured data. The collected data is particular to individuals and can be shared with physicians, emergency systems or athletes’ coaches. Long-time monitoring of activity and potassium concentration in urine can help maintain the appropriate water intake of elderly people or athletes and to send warning signals in the case of near dehydration. The created sensor system was calibrated and tested in laboratory and real conditions as well. The measurement results are discussed.

  1. Non-invasive biomedical research and diagnostics enabled by innovative compact lasers

    Science.gov (United States)

    Litvinova, Karina S.; Rafailov, Ilya E.; Dunaev, Andrey V.; Sokolovski, Sergei G.; Rafailov, Edik U.

    2017-11-01

    For over half a century, laser technology has undergone a technological revolution. These technologies, particularly semiconductor lasers, are employed in a myriad of fields. Optical medical diagnostics, one of the emerging areas of laser application, are on the forefront of application around the world. Optical methods of non- or minimally invasive bio-tissue investigation offer significant advantages over alternative methods, including rapid real-time measurement, non-invasiveness and high resolution (guaranteeing the safety of a patient). These advantages demonstrate the growing success of such techniques. In this review, we will outline the recent status of laser technology applied in the biomedical field, focusing on the various available approaches, particularly utilising compact semiconductor lasers. We will further consider the advancement and integration of several complimentary biophotonic techniques into single multimodal devices, the potential impact of such devices and their future applications. Based on our own studies, we will also cover the simultaneous collection of physiological data with the aid a multifunctional diagnostics system, concentrating on the optimisation of the new technology towards a clinical application. Such data is invaluable for developing algorithms capable of delivering consistent, reliable and meaningful diagnostic information, which can ultimately be employed for the early diagnosis of disease conditions in individuals from around the world.

  2. Non-invasive mechanical ventilation with spinal anesthesia for cesarean delivery.

    Science.gov (United States)

    Erdogan, G; Okyay, D Z; Yurtlu, S; Hanci, V; Ayoglu, H; Koksal, B; Turan, I O

    2010-10-01

    We present the successful use of perioperative non-invasive mechanical ventilation in a morbidly obese pregnant woman with bronchial asthma, severe preeclampsia and pulmonary edema undergoing an emergency cesarean delivery with spinal anesthesia. The combination of non-invasive mechanical ventilation with neuraxial anesthesia may be of value in selected parturients with acute or chronic respiratory insufficiency requiring surgery. Copyright © 2010 Elsevier Ltd. All rights reserved.

  3. 5th German cardiodiagnostic meeting 2013 with the 6th Leipzig Symposium on non-invasive cardiovascular imaging. Challenges and limit of the non-invasive cardiac imaging

    International Nuclear Information System (INIS)

    2013-01-01

    The proceedings on the German cardiodiagnostic meeting 2013 together with the 6th Leipzig Symposium on non-invasive cardiovascular imaging include abstracts concerning the following topics: Imaging in the rhythmology; adults with congenital cardiac defects; cardiac myopathies - myocarditis; cardiac valves (before and after transcutaneous valve replacement); coronary heart diseases; technical developments.

  4. Urinary biomarkers for the non-invasive diagnosis of endometriosis.

    Science.gov (United States)

    Liu, Emily; Nisenblat, Vicki; Farquhar, Cindy; Fraser, Ian; Bossuyt, Patrick M M; Johnson, Neil; Hull, M Louise

    2015-12-23

    About 10% of reproductive-aged women suffer from endometriosis which is a costly chronic disease that causes pelvic pain and subfertility. Laparoscopy is the 'gold standard' diagnostic test for endometriosis, but it is expensive and carries surgical risks. Currently, there are no simple non-invasive or minimally-invasive tests available in clinical practice that accurately diagnoses endometriosis. 1. To provide summary estimates of the diagnostic accuracy of urinary biomarkers for the diagnosis of pelvic endometriosis compared to surgical diagnosis as a reference standard.2. To assess the diagnostic utility of biomarkers that could differentiate ovarian endometrioma from other ovarian masses.Urinary biomarkers were evaluated as replacement tests for surgical diagnosis and as triage tests to inform decisions to undertake surgery for endometriosis. The searches were not restricted to particular study design, language or publication dates. We searched the following databases to 20 April - 31 July 2015: CENTRAL, MEDLINE, EMBASE, CINAHL, PsycINFO, Web of Science, LILACS, OAIster, TRIP and ClinicalTrials.gov (trial register). MEDION, DARE, and PubMed were also searched to identify reviews and guidelines as reference sources of potentially relevant studies. Recently published papers not yet indexed in the major databases were also sought. The search strategy incorporated words in the title, abstract, text words across the record and the medical subject headings (MeSH) and was modified for each database. Published peer-reviewed, randomised controlled or cross-sectional studies of any size were considered, which included prospectively collected samples from any population of reproductive-aged women suspected of having one or more of the following target conditions: ovarian, peritoneal or deep infiltrating endometriosis (DIE). We included studies comparing the diagnostic test accuracy of one or more urinary biomarkers with surgical visualisation of endometriotic lesions. Two

  5. On the possibility of non-invasive multilayer temperature estimation using soft-computing methods.

    Science.gov (United States)

    Teixeira, C A; Pereira, W C A; Ruano, A E; Ruano, M Graça

    2010-01-01

    considered, i.e. five 5-mm spaced spatial points and eight therapeutic intensities (I(SATA)): 0.3, 0.5, 0.7, 1.0, 1.3, 1.5, 1.7 and 2.0W/cm(2). Models were trained and selected to estimate temperature at only four intensities, then during the validation phase, the best-fitted models were analyzed in data collected at the eight intensities. This procedure leads to a more realistic evaluation of the generalisation level of the best-obtained structures. At the end of the identification phase, 82 (preferable) estimator models were achieved. The majority of them present an average maximum absolute error (MAE) inferior to 0.5 degrees C. The best-fitted estimator presents a MAE of only 0.4 degrees C for both the 40 operating conditions. This means that the gold-standard maximum error (0.5 degrees C) pointed for hyperthermia was fulfilled independently of the intensity and spatial position considered, showing the improved generalisation capacity of the identified estimator models. As the majority of the preferable estimator models, the best one presents 6 inputs and 11 neurons. In addition to the appropriate error performance, the estimator models present also a reduced computational complexity and then the possibility to be applied in real-time. A non-invasive temperature estimation model, based on soft-computing technique, was proposed for a three-layered phantom. The best-achieved estimator models presented an appropriate error performance regardless of the spatial point considered (inside or at the interface of the layers) and of the intensity applied. Other methodologies published so far, estimate temperature only in homogeneous media. The main drawback of the proposed methodology is the necessity of a-priory knowledge of the temperature behavior. Data used for training and optimisation should be representative, i.e., they should cover all possible physical situations of the estimation environment.

  6. NON INVASIVE PAIN MANAGEMENT IN POST PARTUM MOTHER WITHEVIDENCE BASED PRACTICE APPROACH

    Directory of Open Access Journals (Sweden)

    Nikmatur Rohmah

    2017-04-01

    Full Text Available Introduction: Pain is a sensation of discomfort that most post-partum mothers complain about, in the case of prolonged pain, the risk of post-partum blues is higher. The usage of evidence based practice method gives a bigger opportunity for nurse and medical attendants to think more critically in making decisions and in performing the appropriate treatment in accordance with the patient's problem and uniqueness. This research aimed to applicate management of non-invasive pain on post partum mother through the approach of evidence based practice. Method: This was a case-study, performed to client Mrs. A P1-1 A0 post sectio caesarea day 1 as there is an indication of suspect cepalo pelvis disproportion secondary arrest. Data were collected at maternity room, dr. Soebandi Regional General Hospital. Using interview, observation, and physical examination. Data analysis was conducted through a descriptive analysis. Result: Through a careful nursing, it is found out that pain location and spreading that generally spotted at the patient’s back during the contraction in the uterus, occurred around the shoulders when evidence-base practice is applied. The basic principle of applying an intervention to non invasive pain based on evidence–base practice are: cutaneous stimulation and distraction, while massaging area was set on the face, while the distraction media was interaction with the baby. Evaluation on evidence –based practice showed that pain is reduced to scale 2, while face and mobilitation become more relaxed. Discussion: Massage was intended to stimulated the production of endorphine and dinorphine that play an important roke to block the pain transmission through the descendent control system. Interaction with the baby was intended to function as a distraction media to dominate the incoming impuls into the ascendant control system,which further may close the gate of the pain transmitter. Both of the interventions were axpected to work

  7. Non-invasive characterization and quality assurance of silicon micro-strip detectors using pulsed infrared laser

    Science.gov (United States)

    Ghosh, P.

    2016-01-01

    The Compressed Baryonic Matter (CBM) experiment at FAIR is composed of 8 tracking stations consisting of roughly 1300 double sided silicon micro-strip detectors of 3 different dimensions. For the quality assurance of prototype micro-strip detectors a non-invasive detector charaterization is developed. The test system is using a pulsed infrared laser for charge injection and characterization, called Laser Test System (LTS). The system is aimed to develop a set of characterization procedures which are non-invasive (non-destructive) in nature and could be used for quality assurances of several silicon micro-strip detectors in an efficient, reliable and reproducible way. The procedures developed (as reported here) uses the LTS to scan sensors with a pulsed infra-red laser driven by step motor to determine the charge sharing in-between strips and to measure qualitative uniformity of the sensor response over the whole active area. The prototype detector modules which are tested with the LTS so far have 1024 strips with a pitch of 58 μm on each side. They are read-out using a self-triggering prototype read-out electronic ASIC called n-XYTER. The LTS is designed to measure sensor response in an automatized procedure at several thousand positions across the sensor with focused infra-red laser light (spot size ≈ 12 μm, wavelength = 1060 nm). The pulse with a duration of ≈ 10 ns and power ≈ 5 mW of the laser pulse is selected such, that the absorption of the laser light in the 300 μm thick silicon sensor produces ≈ 24000 electrons, which is similar to the charge created by minimum ionizing particles (MIP) in these sensors. The laser scans different prototype sensors and various non-invasive techniques to determine characteristics of the detector modules for the quality assurance is reported.

  8. Blood biomarkers for the non-invasive diagnosis of endometriosis.

    Science.gov (United States)

    Nisenblat, Vicki; Bossuyt, Patrick M M; Shaikh, Rabia; Farquhar, Cindy; Jordan, Vanessa; Scheffers, Carola S; Mol, Ben Willem J; Johnson, Neil; Hull, M Louise

    2016-05-01

    About 10% of reproductive-aged women suffer from endometriosis, a costly chronic disease causing pelvic pain and subfertility. Laparoscopy is the gold standard diagnostic test for endometriosis, but is expensive and carries surgical risks. Currently, there are no non-invasive or minimally invasive tests available in clinical practice to accurately diagnose endometriosis. Although other reviews have assessed the ability of blood tests to diagnose endometriosis, this is the first review to use Cochrane methods, providing an update on the rapidly expanding literature in this field. To evaluate blood biomarkers as replacement tests for diagnostic surgery and as triage tests to inform decisions on surgery for endometriosis. Specific objectives include:1. To provide summary estimates of the diagnostic accuracy of blood biomarkers for the diagnosis of peritoneal, ovarian and deep infiltrating pelvic endometriosis, compared to surgical diagnosis as a reference standard.2. To assess the diagnostic utility of biomarkers that could differentiate ovarian endometrioma from other ovarian masses. We did not restrict the searches to particular study designs, language or publication dates. We searched CENTRAL to July 2015, MEDLINE and EMBASE to May 2015, as well as these databases to 20 April 2015: CINAHL, PsycINFO, Web of Science, LILACS, OAIster, TRIP, ClinicalTrials.gov, DARE and PubMed. We considered published, peer-reviewed, randomised controlled or cross-sectional studies of any size, including prospectively collected samples from any population of reproductive-aged women suspected of having one or more of the following target conditions: ovarian, peritoneal or deep infiltrating endometriosis (DIE). We included studies comparing the diagnostic test accuracy of one or more blood biomarkers with the findings of surgical visualisation of endometriotic lesions. Two authors independently collected and performed a quality assessment of data from each study. For each diagnostic test

  9. Imaging modalities for the non-invasive diagnosis of endometriosis.

    Science.gov (United States)

    Nisenblat, Vicki; Bossuyt, Patrick M M; Farquhar, Cindy; Johnson, Neil; Hull, M Louise

    2016-02-26

    About 10% of women of reproductive age suffer from endometriosis. Endometriosis is a costly chronic disease that causes pelvic pain and subfertility. Laparoscopy, the gold standard diagnostic test for endometriosis, is expensive and carries surgical risks. Currently, no non-invasive tests that can be used to accurately diagnose endometriosis are available in clinical practice. This is the first review of diagnostic test accuracy of imaging tests for endometriosis that uses Cochrane methods to provide an update on the rapidly expanding literature in this field. • To provide estimates of the diagnostic accuracy of imaging modalities for the diagnosis of pelvic endometriosis, ovarian endometriosis and deeply infiltrating endometriosis (DIE) versus surgical diagnosis as a reference standard.• To describe performance of imaging tests for mapping of deep endometriotic lesions in the pelvis at specific anatomical sites.Imaging tests were evaluated as replacement tests for diagnostic surgery and as triage tests that would assist decision making regarding diagnostic surgery for endometriosis. We searched the following databases to 20 April 2015: MEDLINE, CENTRAL, EMBASE, CINAHL, PsycINFO, Web of Science, LILACS, OAIster, TRIP, ClinicalTrials.gov, MEDION, DARE, and PubMed. Searches were not restricted to a particular study design or language nor to specific publication dates. The search strategy incorporated words in the title, abstracts, text words across the record and medical subject headings (MeSH). We considered published peer-reviewed cross-sectional studies and randomised controlled trials of any size that included prospectively recruited women of reproductive age suspected of having one or more of the following target conditions: endometrioma, pelvic endometriosis, DIE or endometriotic lesions at specific intrapelvic anatomical locations. We included studies that compared the diagnostic test accuracy of one or more imaging modalities versus findings of surgical

  10. Microwave beamforming for non-invasive patient-specific hyperthermia treatment of pediatric brain cancer

    International Nuclear Information System (INIS)

    Burfeindt, Matthew J; Zastrow, Earl; Hagness, Susan C; Van Veen, Barry D; Medow, Joshua E

    2011-01-01

    We present a numerical study of an array-based microwave beamforming approach for non-invasive hyperthermia treatment of pediatric brain tumors. The transmit beamformer is designed to achieve localized heating-that is, to achieve constructive interference and selective absorption of the transmitted electromagnetic waves at the desired focus location in the brain while achieving destructive interference elsewhere. The design process takes into account patient-specific and target-specific propagation characteristics at 1 GHz. We evaluate the effectiveness of the beamforming approach using finite-difference time-domain simulations of two MRI-derived child head models from the Virtual Family (IT'IS Foundation). Microwave power deposition and the resulting steady-state thermal distribution are calculated for each of several randomly chosen focus locations. We also explore the robustness of the design to mismatch between the assumed and actual dielectric properties of the patient. Lastly, we demonstrate the ability of the beamformer to suppress hot spots caused by pockets of cerebrospinal fluid (CSF) in the brain. Our results show that microwave beamforming has the potential to create localized heating zones in the head models for focus locations that are not surrounded by large amounts of CSF. These promising results suggest that the technique warrants further investigation and development.

  11. Non-Invasive Brain Stimulation: A New Strategy in Mild Cognitive Impairment?

    Science.gov (United States)

    Birba, Agustina; Ibáñez, Agustín; Sedeño, Lucas; Ferrari, Jesica; García, Adolfo M.; Zimerman, Máximo

    2017-01-01

    Non-invasive brain stimulation (NIBS) techniques can significantly modulate cognitive functions in healthy subjects and patients with neuropsychiatric disorders. Recently, they have been applied in patients with mild cognitive impairment (MCI) and subjective cognitive impairment (SCI) to prevent or delay the development of Alzheimer’s disease (AD). Here we review this emerging empirical corpus and discuss therapeutic effects of NIBS on several target functions (e.g., memory for face-name associations and non-verbal recognition, attention, psychomotor speed, everyday memory). Available studies have yielded mixed results, possibly due to differences among their tasks, designs, and samples, let alone the latter’s small sizes. Thus, the impact of NIBS on cognitive performance in MCI and SCI remains to be determined. To foster progress in this direction, we outline methodological approaches that could improve the efficacy and specificity of NIBS in both conditions. Furthermore, we discuss the need for multicenter studies, accurate diagnosis, and longitudinal approaches combining NIBS with specific training regimes. These tenets could cement biomedical developments supporting new treatments for MCI and preventive therapies for AD. PMID:28243198

  12. A Non-invasive Real-time Localization System for Enhanced Efficacy in Nasogastric Intubation.

    Science.gov (United States)

    Sun, Zhenglong; Foong, Shaohui; Maréchal, Luc; Tan, U-Xuan; Teo, Tee Hui; Shabbir, Asim

    2015-12-01

    Nasogastric (NG) intubation is one of the most commonly performed clinical procedures. Real-time localization and tracking of the NG tube passage at the larynx region into the esophagus is crucial for safety, but is lacking in current practice. In this paper, we present the design, analysis and evaluation of a non-invasive real-time localization system using passive magnetic tracking techniques to improve efficacy of the clinical NG intubation process. By embedding a small permanent magnet at the insertion tip of the NG tube, a wearable system containing embedded sensors around the neck can determine the absolute position of the NG tube inside the body in real-time to assist in insertion. In order to validate the feasibility of the proposed system in detecting erroneous tube placement, typical reference intubation trajectories are first analyzed using anatomically correct models and localization accuracy of the system are evaluated using a precise robotic platform. It is found that the root-mean-squared tracking accuracy is within 5.3 mm for both the esophagus and trachea intubation pathways. Experiments were also designed and performed to demonstrate that the system is capable of tracking the NG tube accurately in biological environments even in presence of stationary ferromagnetic objects (such as clinical instruments). With minimal physical modification to the NG tube and clinical process, this system allows accurate and efficient localization and confirmation of correct NG tube placement without supplemental radiographic methods which is considered the current clinical standard.

  13. Fouling development in direct contact membrane distillation: Non-invasive monitoring and destructive analysis

    KAUST Repository

    Fortunato, Luca

    2017-12-26

    Fouling development in direct contact membrane distillation (DCMD) for seawater desalination was evaluated combining in-situ monitoring performed using optical coherence tomography (OCT) together with destructive techniques. The non-invasive monitoring with OCT provided a better understanding of the fouling mechanism by giving an appropriate sampling timing for the membrane autopsy. The on-line monitoring system allowed linking the flux trend with the structure of fouling deposited on the membrane surface. The water vapor flux trend was divided in three phases based on the deposition and formation of different foulants over time. The initial flux decline was due to the deposition of a 50–70 nm porous fouling layer consisting of a mixture of organic compounds and salts. Liquid chromatography with organic carbon detection (LC-OCD) analysis revealed the abundance of biopolymer in the fouling layer formed at the initial phase. In the second phase, formation of carbonate crystals on the membrane surface was observed but did not affect the flux significantly. In the last phase, the water vapor flux dropped to almost zero due to the deposition of a dense thick layer of sulfate crystals on the membrane surface.

  14. Non-invasive evaluation for pulmonary circulatory impairment during exercise in patients with chronic lung disease

    International Nuclear Information System (INIS)

    Yamamoto, Hiroshi

    1990-01-01

    Thallium-201 myocardial scintigraphy was performed at rest and during exercise on sixteen patients with chronic lung disease to evaluate the secondary pulmonary hypertension during exercise with non-invasive technique. An inverse significant correlation was found between thallium activity ratio (TAR) of left ventricle plus ventricular septum to right ventricle and both of pulmonary vascular resistance and right to left ventricular work index ratio during exercise. The patients were divided into three groups according to mean pulmonary arterial pressure (P-bar PA ) at rest and during exercise: the first group consisted of six patients with pulmonary hypertension during exercise (P-bar PA : below 25 mmHg at rest and above 30 mmHg during exercise), the second group consisted of four patients with pulmonary hypertension at rest (P-bar PA above 25 mmHg at rest), and the third group consisted of six patients without pulmonary hypertension (P-bar PA below 25 mmHg at rest, below 30 mmHg during exercise). In the first group, TAR during exercise was lowered than at rest in four patients, and in the second group TAR during exercise was lowered than at rest in all, while in the third group TAR during exercise was increased than at rest in five patients. These results suggest that thallium-201 myocardial scintigraphy can reflect pulmonary hemodynamics during exercise in patients with chronic lung disease and it is of great use to predict the patients with pulmonary hypertension during exercise. (author)

  15. The non-invasive investigation of lumbar disc degeneration in patients with chronic low back pain

    International Nuclear Information System (INIS)

    Buirski, G.

    1989-01-01

    The painful degenerate disc is a recognised cause of low back pain. Magnetic Resonance Imaging (MRI) has now replaced discography in the non-invasive assessment of disk degeneration. However, the prohibitive capital expense of MRI and the small number of MR units in Australia produce limitations in clinical access. In contrast, Computed Tomography (CT) is readily available and is performed in most patients prior to MRI referral. This prospective study was undertaken to determine whether preliminary CT could offer any information about disc degeneration and so reduce the demand on a MRI scanner. 30 consecutive patients were studied all of whom had both CT and MRI examinations. Of a total 107 discs examined by both techniques, MRI was able to identify 37 degenerate discs. Conclusive evidence of degeneration (i.e. the presence of intervertebral gas) was only seen in 3 discs at CT (1 patient). Of the 29 posterior disc bulges found on CT, all were both bulging and degenerate on MRI. Indications for MRI based on the CT findings are recommended. Using these criteria, 13% (4 patients) of this study group could have avoided an expensive and unnecessary MR investigation. A useful algorithm for the investigation and assessment of patients with chronic low back pain is discussed. 8 refs., 5 figs., 1 tab

  16. Targeting neural endophenotypes of eating disorders with non-invasive brain stimulation

    Directory of Open Access Journals (Sweden)

    Katharine A Dunlop

    2016-02-01

    Full Text Available The term eating disorders (ED encompasses a wide variety of disordered eating and compensatory behaviors, and so the term is associated with considerable clinical and phenotypic heterogeneity. This heterogeneity makes optimizing treatment techniques difficult. One class of treatments is non-invasive brain stimulation (NIBS. NIBS, including repetitive transcranial magnetic stimulation (rTMS and transcranial direct current stimulation (tDCS are accessible forms of neuromodulation that alter the cortical excitability of a target brain region. It is crucial for NIBS to be successful that the target is well selected for the patient population in question. Targets may best be selected by stepping back from conventional DSM-5 diagnostic criteria to identify neural substrates of more basic phenotypes, including behavior related rewards and punishment cognitive control, and social processes. These phenotypic dimensions have been recently laid out by the Research Domain Criteria (RDoC initiative. Consequently, this review is intended to identify potential dimensions as outlined by the RDoC and their underlying behavioral and neurobiological targets associated with ED as potential candidates for NIBS and review the available literature on rTMS and tDCS in ED. This review systematically reviews abnormal neural circuitry in ED within the RDoC framework, and also systematically reviews the available literature investigating NIBS as a treatment for ED.

  17. Non-invasive brain stimulation to assess and modulate neuroplasticity in Alzheimer's disease.

    Science.gov (United States)

    Boggio, Paulo Sérgio; Valasek, Claudia Aparecida; Campanhã, Camila; Giglio, Ana Carolina Alem; Baptista, Nathalia Ishikawa; Lapenta, Olivia Morgan; Fregni, Felipe

    2011-10-01

    Alzheimer's disease (AD) is a neurodegenerative and progressive disease related to a gradual decline in cognitive functions such as memory, attention, perceptual-spatial abilities, language, and executive functions. Recent evidence has suggested that interventions promoting neural plasticity can induce significant cognitive gains especially in subjects at risk of or with mild AD. Transcranial magnetic stimulation (TMS) and transcranial direct current stimulation (tDCS) are non-invasive techniques that can induce significant and long-lasting changes in focal and non-focal neuroplasticity. In this review, we present initial preliminary evidence that TMS and tDCS can enhance performance in cognitive functions typically impaired in AD. Also, we reviewed the initial six studies on AD that presented early findings showing cognitive gains such as in recognition memory and language associated with TMS and tDCS treatment. In addition, we showed that TMS has also been used to assess neuroplasticity changes in AD supporting the notion that cortical excitability is changed in AD due to the neurodegenerative process. Due to the safe profile, cost of these tools, and initial clinical trials results, further studies are warranted in order to replicate and extend the initial findings of rTMS and tDCS as cognitive enhancers in AD. Further trials should explore different targets of stimulation along with different paradigms of stimulation including combination with behavioural interventions.

  18. Non-invasive detection of periodontal disease using diffuse reflectance spectroscopy: a clinical study

    Science.gov (United States)

    Prasanth, Chandra Sekhar; Betsy, Joseph; Subhash, Narayanan; Jayanthi, Jayaraj L.; Prasanthila, Janam

    2012-03-01

    In clinical diagnostic procedures, gingival inflammation is considered as the initial stage of periodontal breakdown. This is often detected clinically by bleeding on probing as it is an objective measure of inflammation. Since conventional diagnostic procedures have several inherent drawbacks, development of novel non-invasive diagnostic techniques assumes significance. This clinical study was carried out in 15 healthy volunteers and 25 patients to demonstrate the applicability of diffuse reflectance (DR) spectroscopy for quantification and discrimination of various stages of inflammatory conditions in periodontal disease. The DR spectra of diseased lesions recorded using a point monitoring system consisting of a tungsten halogen lamp and a fiber-optic spectrometer showed oxygenated hemoglobin absorption dips at 545 and 575 nm. Mean DR spectra on normalization shows marked differences between healthy and different stages of gingival inflammation. Among the various DR intensity ratios investigated, involving oxy Hb absorption peaks, the R620/R575 ratio was found to be a good parameter of gingival inflammation. In order to screen the entire diseased area and its surroundings instantaneously, DR images were recorded with an EMCCD camera at 620 and 575 nm. We have observed that using the DR image intensity ratio R620/R575 mild inflammatory tissues could be discriminated from healthy with a sensitivity of 92% and specificity of 93%, and from moderate with a sensitivity of 83% and specificity of 96%. The sensitivity and specificity obtained between moderate and severe inflammation are 82% and 76% respectively.

  19. Prototype of an opto-capacitive probe for non-invasive sensing cerebrospinal fluid circulation

    Science.gov (United States)

    Myllylä, Teemu; Vihriälä, Erkki; Pedone, Matteo; Korhonen, Vesa; Surazynski, Lukasz; Wróbel, Maciej; Zienkiewicz, Aleksandra; Hakala, Jaakko; Sorvoja, Hannu; Lauri, Janne; Fabritius, Tapio; Jedrzejewska-Szczerska, Małgorzata; Kiviniemi, Vesa; Meglinski, Igor

    2017-03-01

    In brain studies, the function of the cerebrospinal fluid (CSF) awakes growing interest, particularly related to studies of the glymphatic system in the brain, which is connected with the complex system of lymphatic vessels responsible for cleaning the tissues. The CSF is a clear, colourless liquid including water (H2O) approximately with a concentration of 99 %. In addition, it contains electrolytes, amino acids, glucose, and other small molecules found in plasma. The CSF acts as a cushion behind the skull, providing basic mechanical as well as immunological protection to the brain. Disturbances of the CSF circulation have been linked to several brain related medical disorders, such as dementia. Our goal is to develop an in vivo method for the non-invasive measurement of cerebral blood flow and CSF circulation by exploiting optical and capacitive sensing techniques simultaneously. We introduce a prototype of a wearable probe that is aimed to be used for long-term brain monitoring purposes, especially focusing on studies of the glymphatic system. In this method, changes in cerebral blood flow, particularly oxy- and deoxyhaemoglobin, are measured simultaneously and analysed with the response gathered by the capacitive sensor in order to distinct the dynamics of the CSF circulation behind the skull. Presented prototype probe is tested by measuring liquid flows inside phantoms mimicking the CSF circulation.

  20. Development of biosensors for non-invasive measurements of heart failure biomarkers in saliva

    Science.gov (United States)

    Alcacer, Albert; Streklas, Angelos; Baraket, Abdoullatif; Zine, Nadia; Errachid, Abdelhamid; Bausells, Joan

    2017-06-01

    Biomedical engineering research today is focused on non-invasive techniques for detection of biomarkers related to specific health issues 1. Three metal layer microelectrode (μE) sensors have been implemented to detect specific biomarkers which can be found in human saliva related with heart failure problems 2 such as interleukin and Tumore Necrosis Factor-α (TNF-α), and used as highly sensitive saliva sensors. We designed specialized μEs combining different technologies for multiple measurements aiming to a lab-on-a-chip future integration. Measurements are based to basic principles of Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS). Thus, certain planar technology was used involving three metal layers of gold, platinum and silver deposited over an oxidized silicon substrate following standard cleanroom procedures of lithography for the definition of μEs, sputtering physical vapor deposition (PVD) for gold, evaporation PVD for silver and platinum, and plasma enhanced chemical vapor deposition (PECVD) for passivation layer of silicon nitride.

  1. Non-invasive baroreflex sensitivity assessment using wavelet transfer function-based time–frequency analysis

    International Nuclear Information System (INIS)

    Keissar, K; Gilad, O; Maestri, R; Pinna, G D; La Rovere, M T

    2010-01-01

    A novel approach for the estimation of baroreflex sensitivity (BRS) is introduced based on time–frequency analysis of the transfer function (TF). The TF method (TF-BRS) is a well-established non-invasive technique which assumes stationarity. This condition is difficult to meet, especially in cardiac patients. In this study, the classical TF was replaced with a wavelet transfer function (WTF) and the classical coherence was replaced with wavelet transform coherence (WTC), adding the time domain as an additional degree of freedom with dynamic error estimation. Error analysis and comparison between WTF-BRS and TF-BRS were performed using simulated signals with known transfer function and added noise. Similar comparisons were performed for ECG and blood pressure signals, in the supine position, of 19 normal subjects, 44 patients with a history of previous myocardial infarction (MI) and 45 patients with chronic heart failure. This yielded an excellent linear association (R > 0.94, p < 0.001) for time-averaged WTF-BRS, validating the new method as consistent with a known method. The additional advantage of dynamic analysis of coherence and TF estimates was illustrated in two physiological examples of supine rest and change of posture showing the evolution of BRS synchronized with its error estimations and sympathovagal balance

  2. Synchronisation signatures in the listening brain: a perspective from non-invasive neuroelectrophysiology.

    Science.gov (United States)

    Weisz, Nathan; Obleser, Jonas

    2014-01-01

    Human magneto- and electroencephalography (M/EEG) are capable of tracking brain activity at millisecond temporal resolution in an entirely non-invasive manner, a feature that offers unique opportunities to uncover the spatiotemporal dynamics of the hearing brain. In general, precise synchronisation of neural activity within as well as across distributed regions is likely to subserve any cognitive process, with auditory cognition being no exception. Brain oscillations, in a range of frequencies, are a putative hallmark of this synchronisation process. Embedded in a larger effort to relate human cognition to brain oscillations, a field of research is emerging on how synchronisation within, as well as between, brain regions may shape auditory cognition. Combined with much improved source localisation and connectivity techniques, it has become possible to study directly the neural activity of auditory cortex with unprecedented spatio-temporal fidelity and to uncover frequency-specific long-range connectivities across the human cerebral cortex. In the present review, we will summarise recent contributions mainly of our laboratories to this emerging domain. We present (1) a more general introduction on how to study local as well as interareal synchronisation in human M/EEG; (2) how these networks may subserve and influence illusory auditory perception (clinical and non-clinical) and (3) auditory selective attention; and (4) how oscillatory networks further reflect and impact on speech comprehension. This article is part of a Special Issue entitled Human Auditory Neuroimaging. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. DEGRO practical guidelines: radiotherapy of breast cancer II. Radiotherapy of non-invasive neoplasia of the breast

    International Nuclear Information System (INIS)

    Souchon, R.; Sautter-Bihl, M.L.; Sedlmayer, F.; Budach, W.; Dunst, J.; Feyer, P.; Fietkau, R.; Sauer, R.; Harms, W.; Wenz, F.; Haase, W.

    2014-01-01

    To complement and update the 2007 practice guidelines of the breast cancer expert panel of the German Society of Radiation Oncology (DEGRO) for radiotherapy (RT) of breast cancer. Owing to its growing clinical relevance, in the current version, a separate paper is dedicated to non-invasive proliferating epithelial neoplasia of the breast. In addition to the more general statements of the German interdisciplinary S3 guidelines, this paper is especially focused on indication and technique of RT in addition to breast conserving surgery. The DEGRO expert panel performed a comprehensive survey of the literature comprising recently published data from clinical controlled trials, systematic reviews as well as meta-analyses, referring to the criteria of evidence-based medicine yielding new aspects compared to 2005 and 2007. The literature search encompassed the period 2008 to September 2012 using databases of PubMed and Guidelines International Network (G-I-N). Search terms were ''non invasive breast cancer'', ''ductal carcinoma in situ, ''dcis'', ''borderline breast lesions'', ''lobular neoplasia'', ''radiotherapy'' and ''radiation therapy''. In addition to the more general statements of the German interdisciplinary S3 guidelines, this paper is especially focused on indications of RT and decision making of non-invasive neoplasia of the breast after surgery, especially ductal carcinoma in situ. Among different non-invasive neoplasia of the breast only the subgroup of pure ductal carcinoma in situ (DCIS; synonym ductal intraepithelial neoplasia, DIN) is considered for further recurrence risk reduction treatment modalities after complete excision of DCIS, particularly RT following breast conserving surgery (BCS), in order to avoid a mastectomy. About half of recurrences are invasive cancers. Up to 50?% of all recurrences require salvage mastectomy. Randomized clinical trials and a huge number of mostly observational studies have unanimously demonstrated that RT significantly

  4. Non-invasive separation of alcoholic and non-alcoholic liver disease with predictive modeling.

    Directory of Open Access Journals (Sweden)

    Jan-Peter Sowa

    Full Text Available BACKGROUND & OBJECTIVE: Currently, a major clinical challenge is to distinguish between chronic liver disease caused by metabolic syndrome (non-alcoholic fatty liver disease, NAFLD from that caused by long term or excessive alcohol consumption (ALD. The etiology of severe liver disease affects treatment options and priorities for liver transplantation and organ allocation. Thus we compared physiologically similar NAFLD and ALD patients to detect biochemical differences for improved separation of these mechanistically overlapping etiologies. METHODS: In a cohort of 31 NAFLD patients with BMI below 30 and a cohort of ALD patient with (ALDC n = 51 or without cirrhosis (ALDNC n = 51 serum transaminases, cell death markers and (adipo-cytokines were assessed. Groups were compared with One-way ANOVA and Tukey's correction. Predictive models were built by machine learning techniques. RESULTS: NAFLD, ALDNC or ALDC patients did not differ in demographic parameters. The ratio of alanine aminotransferase/aspartate aminotransferase--common serum parameters for liver damage--was significantly higher in the NAFLD group compared to both ALD groups (each p<0.0001. Adiponectin and tumor necrosis factor(TNF-alpha were significantly lower in NAFLD than in ALDNC (p<0.05 or ALDC patients (p<0.0001. Significantly higher serum concentrations of cell death markers, hyaluronic acid, adiponectin, and TNF-alpha (each p<0.0001 were found in ALDC compared to ALDNC. Using machine learning techniques we were able to discern NAFLD and ALDNC (up to an AUC of 0.9118±0.0056 or ALDC and ALDNC (up to an AUC of 0.9846±0.0018, respectively. CONCLUSIONS: Machine learning techniques relying on ALT/AST ratio, adipokines and cytokines distinguish NAFLD and ALD. In addition, severity of ALD may be non-invasively diagnosed via serum cytokine concentrations.

  5. Non-invasive airway health measurement using synchrotron x-ray microscopy of high refractive index glass microbeads

    Energy Technology Data Exchange (ETDEWEB)

    Donnelley, Martin, E-mail: martin.donnelley@adelaide.edu.au; Farrow, Nigel; Parsons, David [Respiratory & Sleep Medicine, Women’s and Children’s Hospital, North Adelaide, South Australia (Australia); Robinson Research Institute, University of Adelaide, South Australia (Australia); School of Paediatrics and Reproductive Health, University of Adelaide, South Australia (Australia); Morgan, Kaye; Siu, Karen [School of Physics, Monash University, Victoria (Australia)

    2016-01-28

    Cystic fibrosis (CF) is caused by a gene defect that compromises the ability of the mucociliary transit (MCT) system to clear the airways of debris and pathogens. To directly characterise airway health and the effects of treatments we have developed a synchrotron X-ray microscopy method that non-invasively measures the local rate and patterns of MCT behaviour. Although the nasal airways of CF mice exhibit the CF pathophysiology, there is evidence that nasal MCT is not altered in CF mice1. The aim of this experiment was to determine if our non-invasive local airway health assessment method could identify differences in nasal MCT rate between normal and CF mice, information that is potentially lost in bulk MCT measurements. Experiments were performed on the BL20XU beamline at the SPring-8 Synchrotron in Japan. Mice were anaesthetized, a small quantity of micron-sized marker particles were delivered to the nose, and images of the nasal airways were acquired for 15 minutes. The nasal airways were treated with hypertonic saline or mannitol to increase surface hydration and MCT. Custom software was used to locate and track particles and calculate individual and bulk MCT rates. No statistically significant differences in MCT rate were found between normal and CF mouse nasal airways or between treatments. However, we hope that the improved sensitivity provided by this technique will accelerate the ability to identify useful CF lung disease-modifying interventions in small animal models, and enhance the development and efficacy of proposed new therapies.

  6. Evaluation of non-invasive multispectral imaging as a tool for measuring the effect of systemic therapy in Kaposi sarcoma.

    Directory of Open Access Journals (Sweden)

    Jana M Kainerstorfer

    Full Text Available Diffuse multi-spectral imaging has been evaluated as a potential non-invasive marker of tumor response. Multi-spectral images of Kaposi sarcoma skin lesions were taken over the course of treatment, and blood volume and oxygenation concentration maps were obtained through principal component analysis (PCA of the data. These images were compared with clinical and pathological responses determined by conventional means. We demonstrate that cutaneous lesions have increased blood volume concentration and that changes in this parameter are a reliable indicator of treatment efficacy, differentiating responders and non-responders. Blood volume decreased by at least 20% in all lesions that responded by clinical criteria and increased in the two lesions that did not respond clinically. Responses as assessed by multi-spectral imaging also generally correlated with overall patient clinical response assessment, were often detectable earlier in the course of therapy, and are less subject to observer variability than conventional clinical assessment. Tissue oxygenation was more variable, with lesions often showing decreased oxygenation in the center surrounded by a zone of increased oxygenation. This technique could potentially be a clinically useful supplement to existing response assessment in KS, providing an early, quantitative, and non-invasive marker of treatment effect.

  7. Non-invasive airway health measurement using synchrotron x-ray microscopy of high refractive index glass microbeads

    Science.gov (United States)

    Donnelley, Martin; Morgan, Kaye; Farrow, Nigel; Siu, Karen; Parsons, David

    2016-01-01

    Cystic fibrosis (CF) is caused by a gene defect that compromises the ability of the mucociliary transit (MCT) system to clear the airways of debris and pathogens. To directly characterise airway health and the effects of treatments we have developed a synchrotron X-ray microscopy method that non-invasively measures the local rate and patterns of MCT behaviour. Although the nasal airways of CF mice exhibit the CF pathophysiology, there is evidence that nasal MCT is not altered in CF mice1. The aim of this experiment was to determine if our non-invasive local airway health assessment method could identify differences in nasal MCT rate between normal and CF mice, information that is potentially lost in bulk MCT measurements. Experiments were performed on the BL20XU beamline at the SPring-8 Synchrotron in Japan. Mice were anaesthetized, a small quantity of micron-sized marker particles were delivered to the nose, and images of the nasal airways were acquired for 15 minutes. The nasal airways were treated with hypertonic saline or mannitol to increase surface hydration and MCT. Custom software was used to locate and track particles and calculate individual and bulk MCT rates. No statistically significant differences in MCT rate were found between normal and CF mouse nasal airways or between treatments. However, we hope that the improved sensitivity provided by this technique will accelerate the ability to identify useful CF lung disease-modifying interventions in small animal models, and enhance the development and efficacy of proposed new therapies.

  8. The potential of Internet of m-health Things "m-IoT" for non-invasive glucose level sensing.

    Science.gov (United States)

    Istepanian, R S H; Hu, S; Philip, N Y; Sungoor, A

    2011-01-01

    An amalgamated concept of Internet of m-health Things (m-IoT) has been introduced recently and defined as a new concept that matches the functionalities of m-health and IoT for a new and innovative future (4G health) applications. It is well know that diabetes is a major chronic disease problem worldwide with major economic and social impact. To-date there have not been any studies that address the potential of m-IoT for non-invasive glucose level sensing with advanced opto-physiological assessment technique and diabetes management. In this paper we address the potential benefits of using m-IoT in non-invasive glucose level sensing and the potential m-IoT based architecture for diabetes management. We expect to achieve intelligent identification and management in a heterogeneous connectivity environment from the mobile healthcare perspective. Furthermore this technology will enable new communication connectivity routes between mobile patients and care services through innovative IP based networking architectures.

  9. Adaptive control with self-tuning for non-invasive beat-by-beat blood pressure measurement.

    Science.gov (United States)

    Nogawa, Masamichi; Ogawa, Mitsuhiro; Yamakoshi, Takehiro; Tanaka, Shinobu; Yamakoshi, Ken-ichi

    2011-01-01

    Up to now, we have successfully carried out the non-invasive beat-by-beat measurement of blood pressure (BP) in the root of finger, superficial temporal and radial artery based on the volume-compensation technique with reasonable accuracy. The present study concerns with improvement of control method for this beat-by-beat BP measurement. The measurement system mainly consists of a partial pressurization cuff with a pair of LED and photo-diode for the detection of arterial blood volume, and a digital self-tuning control method. Using healthy subjects, the performance and accuracy of this system were evaluated through comparison experiments with the system using a conventional empirically tuned PID controller. The significant differences of BP measured in finger artery were not showed in systolic (SBP), p=0.52, and diastolic BP (DBP), p=0.35. With the advantage of the adaptive control with self-tuning method, which can tune the control parameters without disturbing the control system, the application area of the non-invasive beat-by-beat measurement method will be broadened.

  10. Non-invasive red light optogenetic pacing and optical coherence microscopy (OCM) imaging for drosophila melanogaster (Conference Presentation)

    Science.gov (United States)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Cardiac pacing could be a powerful tool for investigating mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, traditional electrical pacing using pacemaker requires an invasive surgical procedure. Electrical currents from the implanted electrodes can also cause damage to heart tissue, further restricting its utility. Optogenetic pacing has been developed as a promising, non-invasive alternative to electrical stimulation for controlling animal heart rhythms. It induces heart contractions by shining pulsed light on transgene-generated microbial opsins, which in turn activate the light gated ion channels in animal hearts. However, commonly used opsins in optogenetic pacing, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we performed optogenetic pacing by expression of recently engineered red-shifted microbial opsins, ReaChR and CsChrimson, in a well-established animal model, Drosophila melanogaster, using the 617 nm stimulation light pulses. The OCM technique enables non-invasive optical imaging of animal hearts with high speed and ultrahigh axial and transverse resolutions. We integrated a customized OCM system with the optical stimulation system to monitor the optogenetic pacing noninvasively. The use of red-sifted opsins enabled deeper penetration of simulating light at lower power, which is promising for applications of optogenetic pacing in mammalian cardiac pathology studies or clinical treatments in the future.

  11. Non-invasive in vivo imaging of arthritis in a collagen-induced murine model with phosphatidylserine-binding near-infrared (NIR) dye

    OpenAIRE

    Chan, Marion M; Gray, Brian D; Pak, Koon Y; Fong, Dunne

    2015-01-01

    Introduction Development of non-invasive molecular imaging techniques that are based on cellular changes in inflammation has been of active interest for arthritis diagnosis. This technology will allow real-time detection of tissue damage and facilitate earlier treatment of the disease, thus representing an improvement over X-rays, which detect bone damage at the advanced stage. Tracing apoptosis, an event occurring in inflammation, has been a strategy used. PSVue 794 is a low-molecular-weight...

  12. Infrared irradiation of skin for the development of non-invasive health monitoring technologies

    Science.gov (United States)

    Abdussamad Abbas, Hisham; Triplett, Gregory

    2015-06-01

    Infrared radiation was employed to study the optical transmission properties of pigskin and the factors that influence transmission at room temperature. The skin samples from the forehead of piglets were irradiated using an infrared-pulsed source by varying the beam properties such as optical power, power density, duty cycle, as well as sample thickness. Because infrared radiation in select instances can penetrate through thick-fleshy skin more easily than visible radiation, temperature fluctuations observed within the skin samples stemming from exposure-dependent absorption revealed interesting transmission properties and the limits of optical exposure. Pigskin was selected for this study since its structure most closely resembles that of human skin. Furthermore, the pulsed beam technique compared to continuous operation offers more precise control of heat generation within the skin. Through this effort, the correlated pulsed-beam parameters that influence infrared transmission were identified and varied to minimize the internal absorption losses through the dermis layers. The two most significant parameters that reduce absorption losses were frequency and duty cycle of the pulsed beam. Using the Bouger-Beer-Lambert Law, the absorption coefficient from empirical data is approximated, while accepting that the absorption coefficient is neither uniform nor linear. Given that the optical source used in this study was single mode, the infrared spectra obtained from irradiated samples also reveal characteristics of the skin structure. Realization of appropriate sample conditions and exposure parameters that reduce light attenuation within the skin and sample degradation could give way to novel non-invasive measuring techniques for health monitoring purposes.

  13. NOTE: A preliminary study for non-invasive quantification of manganese in human hand bones

    Science.gov (United States)

    Aslam; Pejović-Milić, A.; Chettle, D. R.; McNeill, F. E.; Pysklywec, M. W.; Oudyk, J.

    2008-10-01

    Manganese (Mn) is a nutrient essential for regulating neurological and skeletal functions in the human body, but it is also toxic when humans are excessively exposed to Mn. Blood (or serum/plasma) and other body fluids reflect only the most recent exposure and rapidly return to within normal ranges, even when there has been a temporary excursion in response to exposure. In this context, we have been developing a non-invasive measurement of Mn stored in bone, using in vivo neutron activation analysis. Following feasibility studies, a first pilot study, using neutron activation analysis to measure Mn in the bones of the hand of ten healthy male human subjects, was conducted with the approval of the concerned research ethics boards. The participants of this study had no known history of exposure to Mn. Two volunteers were excluded from this study due to technical problems with their measurements. The inverse variance weighted mean value of Mn/Ca for the participants of this study is 0.12 ± 0.68 µg Mn/g Ca which is comparable within uncertainties with the estimated range of 0.16 0.78 µg Mn/g Ca and mean value of 0.63 ± 0.30 µg Mn/g Ca derived from cadaver data. It is recommended to investigate the use of the diagnostic technique for in vivo measurements of workers exposed occupationally to excessive amounts of Mn who could develop many-fold increased levels of Mn in bones as demonstrated through various animal studies. The technique needs further development to improve the precision of in vivo measurements in the non-exposed population.

  14. Two-photon microscopy for non-invasive, quantitative monitoring of stem cell differentiation.

    Directory of Open Access Journals (Sweden)

    William L Rice

    Full Text Available BACKGROUND: The engineering of functional tissues is a complex multi-stage process, the success of which depends on the careful control of culture conditions and ultimately tissue maturation. To enable the efficient optimization of tissue development protocols, techniques suitable for monitoring the effects of added stimuli and induced tissue changes are needed. METHODOLOGY/PRINCIPAL FINDINGS: Here, we present the quantitative use of two-photon excited fluorescence (TPEF and second harmonic generation (SHG as a noninvasive means to monitor the differentiation of human mesenchymal stem cells (hMSCs using entirely endogenous sources of contrast. We demonstrate that the individual fluorescence contribution from the intrinsic cellular fluorophores NAD(PH, flavoproteins and lipofuscin can be extracted from TPEF images and monitored dynamically from the same cell population over time. Using the redox ratio, calculated from the contributions of NAD(PH and flavoproteins, we identify distinct patterns in the evolution of the metabolic activity of hMSCs maintained in either propagation, osteogenic or adipogenic differentiation media. The differentiation of these cells is mirrored by changes in cell morphology apparent in high resolution TPEF images and by the detection of collagen production via SHG imaging. Finally, we find dramatic increases in lipofuscin levels in hMSCs maintained at 20% oxygen vs. those in 5% oxygen, establishing the use of this chromophore as a potential biomarker for oxidative stress. CONCLUSIONS/SIGNIFICANCE: In this study we demonstrate that it is possible to monitor the metabolic activity, morphology, ECM production and oxidative stress of hMSCs in a non-invasive manner. This is accomplished using generally available multiphoton microscopy equipment and simple data analysis techniques, such that the method can widely adopted by laboratories with a diversity of comparable equipment. This method therefore represents a powerful tool

  15. Wireless network system based multi-non-invasive sensors for smart home

    Science.gov (United States)

    Issa Ahmed, Rudhwan

    There are several techniques that have been implemented for smart homes usage; however, most of these techniques are limited to a few sensors. Many of these methods neither meet the needs of the user nor are cost-effective. This thesis discusses the design, development, and implementation of a wireless network system, based on multi-non-invasive sensors for smart home environments. This system has the potential to be used as a means to accurately, and remotely, determine the activities of daily living by continuously monitoring relatively simple parameters that measure the interaction between users and their surrounding environment. We designed and developed a prototype system to meet the specific needs of the elderly population. Unlike audio-video based health monitoring systems (which have associated problems such as the encroachment of privacy), the developed system's distinct features ensure privacy and are almost invisible to the occupants, thus increasing the acceptance levels of this system in household environments. The developed system not only achieved high levels of accuracy, but it is also portable, easy to use, cost-effective, and requires low data rates and less power compared to other wireless devices such as Wi-Fi, Bluetooth, wireless USB, Ultra wideband (UWB), or Infrared (IR) wireless. Field testing of the prototype system was conducted at different locations inside and outside of the Minto Building (Centre for Advanced Studies in Engineering at Carleton University) as well as other locations, such as the washroom, kitchen, and living room of a prototype apartment. The main goal of the testing was to determine the range of the prototype system and the functionality of each sensor in different environments. After it was verified that the system operated well in all of the tested environments, data were then collected at the different locations for analysis and interpretation in order to identify the activities of daily living of an occupant.

  16. Cognitive and Neurophysiological Effects of Non-invasive Brain Stimulation in Stroke Patients after Motor Rehabilitation.

    Science.gov (United States)

    D'Agata, Federico; Peila, Elena; Cicerale, Alessandro; Caglio, Marcella M; Caroppo, Paola; Vighetti, Sergio; Piedimonte, Alessandro; Minuto, Alice; Campagnoli, Marcello; Salatino, Adriana; Molo, Maria T; Mortara, Paolo; Pinessi, Lorenzo; Massazza, Giuseppe

    2016-01-01

    The primary aim of this study was to evaluate and compare the effectiveness of two specific Non-Invasive Brain Stimulation (NIBS) paradigms, the repetitive Transcranial Magnetic Stimulation (rTMS), and transcranial Direct Current Stimulation (tDCS), in the upper limb rehabilitation of patients with stroke. Short and long term outcomes (after 3 and 6 months, respectively) were evaluated. We measured, at multiple time points, the manual dexterity using a validated clinical scale (ARAT), electroencephalography auditory event related potentials, and neuropsychological performances in patients with chronic stroke of middle severity. Thirty four patients were enrolled and randomized. The intervention group was treated with a NIBS protocol longer than usual, applying a second cycle of stimulation, after a washout period, using different techniques in the two cycles (rTMS/tDCS). We compared the results with a control group treated with sham stimulation. We split the data analysis into three studies. In this first study we examined if a cumulative effect was clinically visible. In the second study we compared the effects of the two techniques. In the third study we explored if patients with minor cognitive impairment have most benefit from the treatment and if cognitive and motor outcomes were correlated. We found that the impairment in some cognitive domains cannot be considered an exclusion criterion for rehabilitation with NIBS. ERP improved, related to cognitive and attentional processes after stimulation on the motor cortex, but transitorily. This effect could be linked to the restoration of hemispheric balance or by the effects of distant connections. In our study the effects of the two NIBS were comparable, with some advantages using tDCS vs. rTMS in stroke rehabilitation. Finally we found that more than one cycle (2-4 weeks), spaced out by washout periods, should be used, only in responder patients, to obtain clinical relevant results.

  17. A preliminary study for non-invasive quantification of manganese in human hand bones

    International Nuclear Information System (INIS)

    Aslam; Pejovic-Milic, A; Chettle, D R; McNeill, F E; Pysklywec, M W; Oudyk, J

    2008-01-01

    Manganese (Mn) is a nutrient essential for regulating neurological and skeletal functions in the human body, but it is also toxic when humans are excessively exposed to Mn. Blood (or serum/plasma) and other body fluids reflect only the most recent exposure and rapidly return to within normal ranges, even when there has been a temporary excursion in response to exposure. In this context, we have been developing a non-invasive measurement of Mn stored in bone, using in vivo neutron activation analysis. Following feasibility studies, a first pilot study, using neutron activation analysis to measure Mn in the bones of the hand of ten healthy male human subjects, was conducted with the approval of the concerned research ethics boards. The participants of this study had no known history of exposure to Mn. Two volunteers were excluded from this study due to technical problems with their measurements. The inverse variance weighted mean value of Mn/Ca for the participants of this study is 0.12 ± 0.68 μg Mn/g Ca which is comparable within uncertainties with the estimated range of 0.16-0.78 μg Mn/g Ca and mean value of 0.63 ± 0.30 μg Mn/g Ca derived from cadaver data. It is recommended to investigate the use of the diagnostic technique for in vivo measurements of workers exposed occupationally to excessive amounts of Mn who could develop many-fold increased levels of Mn in bones as demonstrated through various animal studies. The technique needs further development to improve the precision of in vivo measurements in the non-exposed population. (note)

  18. Non-Invasive Radiofrequency-Induced Targeted Hyperthermia for the Treatment of Hepatocellular Carcinoma

    Directory of Open Access Journals (Sweden)

    Mustafa Raoof

    2011-01-01

    Full Text Available Targeted biological therapies for hepatocellular cancer have shown minimal improvements in median survival. Multiple pathways to oncogenesis leading to rapid development of resistance to such therapies is a concern. Non-invasive radiofrequency field-induced targeted hyperthermia using nanoparticles is a radical departure from conventional modalities. In this paper we underscore the need for innovative strategies for the treatment of hepatocellular cancer, describe the central paradigm of targeted hyperthermia using non-invasive electromagnetic energy, review the process of characterization and modification of nanoparticles for the task, and summarize data from cell-based and animal-based models of hepatocellular cancer treated with non-invasive RF energy. Finally, future strategies and challenges in bringing this modality from bench to clinic are discussed.

  19. Non-Invasive Mechanic Ventilation Using in Flail Chest, Caused By Blunt Chest Trauma

    Directory of Open Access Journals (Sweden)

    Serdar Onat

    2008-01-01

    Full Text Available A 75-year-old woman admitted our faculty emergency room with shortness of breath, and chest pain after traffic accident’s second hour. She was diagnosed as bilateral multipl rib fractures, left clavicula fracture, and left flail chest by phsical and radiological examinations. She was transfered to Chest Surgery Depatment’s intensive care unit. The patient was undergone non-invasive mask mechanic ventilation support, because of the decreasing of blood oxygen saturation and increasing of arteriel blood partial carbondioxide pressure. The treatment of non-invasive mechanic ventilation was succesfull for ventilation support. With this report, we would like to attentioned that non-invasive mechanic ventilation for blunt chest trauma patients could be used succesfully and could be used instead of endotracheal invasive mechanic ventilation.

  20. Intraspecies differenes in phenotypic plasticity: Invasive versus non-invasive populations of Ceratophyllum demersum

    DEFF Research Database (Denmark)

    Hyldgaard, Benita; Brix, Hans

    2012-01-01

    High phenotypic plasticity has been hypothesized to affect the invasiveness of plants, as high plasticity may enlarge the breath of environments in which the plants can survive and reproduce. Here we compare the phenotypic plasticity of invasive and non-invasive populations of the same species...... hypothesized that the phenotypic plasticity in fitness-related traits like growth and photosynthesis were higher in the invasive than in the non-invasive population. The invasive population acclimated to elevated temperatures through increased rates of photosynthesis (range: Pamb: 8–452 mol O2 g−1 DM h−1......-harvesting complex. Hence, the invasive population of C. demersum from New Zealand had higher phenotypic plasticity in response to temperature than the non-invasive Danish population. This might be the result of genetic evolution since its introduction to New Zealand five decades ago, but further studies are needed...

  1. British Thoracic Society Quality Standards for acute non-invasive ventilation in adults

    Science.gov (United States)

    Davies, Michael; Allen, Martin; Bentley, Andrew; Bourke, Stephen C; Creagh-Brown, Ben; D’Oliveiro, Rachel; Glossop, Alastair; Gray, Alasdair; Jacobs, Phillip; Mahadeva, Ravi; Moses, Rachael; Setchfield, Ian

    2018-01-01

    Introduction The purpose of the quality standards document is to provide healthcare professionals, commissioners, service providers and patients with a guide to standards of care that should be met for the provision of acute non-invasive ventilation in adults together with measurable markers of good practice. Methods Development of British Thoracic Society (BTS) Quality Standards follows the BTS process of quality standard production based on the National Institute for Health and Care Excellence process manual for the development of quality standards. Results 6 quality statements have been developed, each describing a standard of care for the provision of acute non-invasive ventilation in the UK, together with measurable markers of good practice. Conclusion BTS Quality Standards for acute non-invasive ventilation in adults form a key part of the range of supporting materials that the Society produces to assist in the dissemination and implementation of guideline’s recommendations. PMID:29636979

  2. Recent research findings on non-invasive diagnosis of liver fibrosis

    Directory of Open Access Journals (Sweden)

    WU Qiong

    2015-02-01

    Full Text Available Early diagnosis of liver fibrosis and dynamic monitoring of relevant changes have great implications for the treatment and prognosis improvement of chronic liver diseases. So far, liver biopsy remains the “golden standard” for the diagnosis and staging of liver fibrosis. However, due to its inherent limitations, a great effort has been made to develop more accurate non-invasive diagnostic methods, including serum fibrosis markers and mathematical models, ultrasound, contrast-enhanced ultrasonography, ultrasonic elastography, computed tomography, magnetic resonance imaging, and nuclear medicine. The advantages and disadvantages of relevant methods are discussed. Furthermore, proper selection of the non-invasive diagnostic methods for clinical application and the means for mutual verification are analyzed. As for the future direction, it is expected to employ the above methods for combined analysis and comprehensive assessment, in order to enhance the clinical value of non-invasive liver fibrosis diagnosis.

  3. From mini-invasive to non-invasive treatment using monopolar radiofrequency: the next orthopaedic frontier.

    Science.gov (United States)

    Whipple, Terry L

    2009-10-01

    Tendinopathy arises from a failed tendon healing process. Current non-invasive therapeutic alternatives are anti-inflammatory in nature, and outcomes are unpredictable. The benefit of invasive alternatives resides in the induction of the healing response. A new technology that uses non-invasive monopolar capacitive coupled radiofrequency has demonstrated the ability to raise temperatures in tendons and ligaments above 50 degrees C, the threshold for collagen modulation, tissue shrinkage and recruitment of macrophages, fibroblasts, and heat shock protein factors, without damaging the overlying structures, resulting in activation of the wound healing response. Monopolar capacitive-coupled radiofrequency offers a new non-invasive choice for tendinopathies and sprained ligaments. It does not interfere with subsequent surgical procedures should they become necessary.

  4. Radio frequency energy for non-invasive and minimally invasive skin tightening.

    Science.gov (United States)

    Mulholland, R Stephen

    2011-07-01

    This article reviews the non-invasive and minimally invasive options for skin tightening, focusing on peer-reviewed articles and presentations and those technologies with the most proven or promising RF non-excisional skin-tightening results for excisional surgeons. RF has been the mainstay of non-invasive skin tightening and has emerged as the "cutting edge" technology in the minimally invasive skin-tightening field. Because these RF skin-tightening technologies are capital equipment purchases with a significant cost associated, this article also discusses some business issues and models that have proven to work in the plastic surgeon's office for non-invasive and minimally invasive skin-tightening technologies. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Non-invasive vascular imaging in perforator flap surgery

    International Nuclear Information System (INIS)

    Saba, Luca; Piga, Mario; Atzeni, Matteo; Ribuffo, Diego; Rozen, Warren Matthew; Alonso-Burgos, Alberto; Bura, Raffaella

    2013-01-01

    Preoperative imaging using a range of imaging modalities has become increasingly popular for preoperative planning in plastic surgery, in particular in perforator flap surgery. Modalities in this role include ultrasound (US), magnetic resonance angiography (MRA), and computed tomographic angiography (CTA). The evidence for the use of these techniques has been reported in only a handful of studies. In this paper we conducted a non-systematic review of the literature to establish the role for each of these modalities. The role of state-of-the-art vascular imaging as an application in perforator flap surgery is thus offered

  6. Fluid challenge: tracking changes in cardiac output with blood pressure monitoring (invasive or non-invasive).

    Science.gov (United States)

    Lakhal, Karim; Ehrmann, Stephan; Perrotin, Dominique; Wolff, Michel; Boulain, Thierry

    2013-11-01

    To assess whether invasive and non-invasive blood pressure (BP) monitoring allows the identification of patients who have responded to a fluid challenge, i.e., who have increased their cardiac output (CO). Patients with signs of circulatory failure were prospectively included. Before and after a fluid challenge, CO and the mean of four intra-arterial and oscillometric brachial cuff BP measurements were collected. Fluid responsiveness was defined by an increase in CO ≥10 or ≥15% in case of regular rhythm or arrhythmia, respectively. In 130 patients, the correlation between a fluid-induced increase in pulse pressure (Δ500mlPP) and fluid-induced increase in CO was weak and was similar for invasive and non-invasive measurements of BP: r² = 0.31 and r² = 0.29, respectively (both p area under the receiver-operating curve (AUC) of 0.82 (0.74-0.88), similar (p = 0.80) to that of non-invasive Δ500mlPP [AUC of 0.81 (0.73-0.87)]. Outside large gray zones of inconclusive values (5-23% for invasive Δ500mlPP and 4-35% for non-invasive Δ500mlPP, involving 35 and 48% of patients, respectively), the detection of responsiveness or unresponsiveness to fluid was reliable. Cardiac arrhythmia did not impair the performance of invasive or non-invasive Δ500mlPP. Other BP-derived indices did not outperform Δ500mlPP. As evidenced by large gray zones, BP-derived indices poorly reflected fluid responsiveness. However, in our deeply sedated population, a high increase in invasive pulse pressure (>23%) or even in non-invasive pulse pressure (>35%) reliably detected a response to fluid. In the absence of a marked increase in pulse pressure (<4-5%), a response to fluid was unlikely.

  7. Capacitive Sensing for Non-Invasive Breathing and Heart Monitoring in Non-Restrained, Non-Sedated Laboratory Mice

    Directory of Open Access Journals (Sweden)

    Carlos González-Sánchez

    2016-07-01

    Full Text Available Animal testing plays a vital role in biomedical research. Stress reduction is important for improving research results and increasing the welfare and the quality of life of laboratory animals. To estimate stress we believe it is of great importance to develop non-invasive techniques for monitoring physiological signals during the transport of laboratory animals, thereby allowing the gathering of information on the transport conditions, and, eventually, the improvement of these conditions. Here, we study the suitability of commercially available electric potential integrated circuit (EPIC sensors, using both contact and contactless techniques, for monitoring the heart rate and breathing rate of non-restrained, non-sedated laboratory mice. The design has been tested under different scenarios with the aim of checking the plausibility of performing contactless capture of mouse heart activity (ideally with an electrocardiogram. First experimental results are shown.

  8. Capacitive Sensing for Non-Invasive Breathing and Heart Monitoring in Non-Restrained, Non-Sedated Laboratory Mice.

    Science.gov (United States)

    González-Sánchez, Carlos; Fraile, Juan-Carlos; Pérez-Turiel, Javier; Damm, Ellen; Schneider, Jochen G; Zimmermann, Heiko; Schmitt, Daniel; Ihmig, Frank R

    2016-07-07

    Animal testing plays a vital role in biomedical research. Stress reduction is important for improving research results and increasing the welfare and the quality of life of laboratory animals. To estimate stress we believe it is of great importance to develop non-invasive techniques for monitoring physiological signals during the transport of laboratory animals, thereby allowing the gathering of information on the transport conditions, and, eventually, the improvement of these conditions. Here, we study the suitability of commercially available electric potential integrated circuit (EPIC) sensors, using both contact and contactless techniques, for monitoring the heart rate and breathing rate of non-restrained, non-sedated laboratory mice. The design has been tested under different scenarios with the aim of checking the plausibility of performing contactless capture of mouse heart activity (ideally with an electrocardiogram). First experimental results are shown.

  9. Resolution of obstructive atelectasis with non-invasive mechanical ventilation.

    Science.gov (United States)

    Mirambeaux Villalona, Rosa; Mayoralas Alises, Sagrario; Díaz Lobato, Salvador

    2014-10-01

    Bronchoscopy is a commonly used technique in patients with atelectasis due to mucus plugs. We present here the case of an 82-year-old patient with a history of Meige's syndrome who developed acute respiratory failure due to atelectasis of the right upper lobe associated with hospital-acquired pneumonia. The patient had a severely reduced level of consciousness, significant work-of-breathing and severe hypercapnic acidosis, all of which contraindicated bronchoscopy. Bi-level noninvasive mechanical ventilation (NIMV) was initiated by way of a face mask. Progress was favourable, with clear clinical and gasometric improvement. The chest X-ray performed 12hours later showed complete resolution of the atelectasis. These data suggest that NIMV may be useful in the treatment of atelectasis is some critical patients. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.

  10. Non-invasive Morphological and Elemental Analysis of Ivory Plate for Artworks\

    Czech Academy of Sciences Publication Activity Database

    Tihlaříková, Eva; Neděla, Vilém; Hradilová, J.; Hradil, David

    2017-01-01

    Roč. 23, S1 (2017), s. 1832-1833 ISSN 1431-9276 R&D Projects: GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01; GA ČR(CZ) GA17-25687S Institutional support: RVO:68081731 ; RVO:61388980 Keywords : ESEM * EDS * non-invasive morphological analysis * non-invasive elemental analysis Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering; CA - Inorganic Chemistry (UACH-T) OBOR OECD: Microbiology; Inorganic and nuclear chemistry (UACH-T) Impact factor: 1.891, year: 2016

  11. Non-Invasive Acoustic-Based Monitoring of Heavy Water and Uranium Process Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Pantea, Cristian [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sinha, Dipen N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lakis, Rollin Evan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Beedle, Christopher Craig [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Davis, Eric Sean [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-20

    This presentation includes slides on Project Goals; Heavy Water Production Monitoring: A New Challenge for the IAEA; Noninvasive Measurements in SFAI Cell; Large Scatter in Literature Values; Large Scatter in Literature Values; Highest Precision Sound Speed Data Available: New Standard in H/D; ~400 pts of data; Noninvasive Measurements in SFAI Cell; New funding from NA241 SGTech; Uranium Solution Monitoring: Inspired by IAEA Challenge in Kazakhstan; Non-Invasive Acoustic-Based Monitoring of Uranium in Solutions; Non-Invasive Acoustic-Based Monitoring of Uranium in Solutions; and finally a summary.

  12. [Clinical guidelines for diagnosis, treatment and monitoring of patients with non-invasive breast cancer].

    Science.gov (United States)

    Brnijć, Zoran; Brkljacić, Boris; Drinković, Ivan; Jakić-Razumović, Jasminka; Kardum-Skelin, Ika; Krajina, Zdenko; Margaritoni, Marko; Strnad, Marija; Sarcević, Bozena; Tomić, Snjezana; Zic, Rado

    2012-01-01

    Breast cancer is the most common malignancy in women. Early diagnosis and more effective treatment of invasive breast cancer resulted in significant mortality reduction, improvement of survival and the quality of life of the patients. The management od non-invasive breast cancer, on the contrary, is still controversial and the problem of overdiagnosis and overtreatment of patients come to evidence. In the following text a multidisciplinary team of experts brings the first consensus guidelines aimed to standardize and optimize the criteria and management in diagnosis, treatment and monitoring of non-invasive breast cancer patients in the Republic of Croatia.

  13. Non-Invasive In Vivo Ultrasound Temperature Estimation

    Science.gov (United States)

    Bayat, Mahdi

    New emerging technologies in thermal therapy require precise monitoring and control of the delivered thermal dose in a variety of situations. The therapeutic temperature changes in target tissues range from few degrees for releasing chemotherapy drugs encapsulated in the thermosensitive liposomes to boiling temperatures in complete ablation of tumors via cell necrosis. High intensity focused ultrasound (HIFU) has emerged as a promising modality for noninvasive surgery due to its ability to create precise mechanical and thermal effects at the target without affecting surrounding tissues. An essential element in all these procedures, however, is accurate estimation of the target tissue temperature during the procedure to ensure its safety and efficacy. The advent of diagnostic imaging tools for guidance of thermal therapy was a key factor in the clinical acceptance of these minimally invasive or noninvasive methods. More recently, ultrasound and magnetic resonance (MR) thermography techniques have been proposed for guidance, monitoring, and control of noninvasive thermal therapies. MR thermography has shown acceptable sensitivity and accuracy in imaging temperature change and it is currently FDA-approved on clinical HIFU units. However, it suffers from limitations like cost of integration with ultrasound therapy system and slow rate of imaging for real time guidance. Ultrasound, on the other hand, has the advantage of real time imaging and ease of integration with the therapy system. An infinitesimal model for imaging temperature change using pulse-echo ultrasound has been demonstrated, including in vivo small-animal imaging. However, this model suffers from limitations that prevent demonstration in more clinically-relevant settings. One limitation stems from the infinitesimal nature of the model, which results in spatial inconsistencies of the estimated temperature field. Another limitation is the sensitivity to tissue motion and deformation during in vivo, which

  14. Non-invasive endodontic treatment of large periapical lesions

    Directory of Open Access Journals (Sweden)

    Harry Huiz Peeters

    2008-09-01

    Full Text Available Background: In most cases of large periapical radiolucent lesions of pulpal origin, we often encounter a dilemmatic situation, such as whether to either treat these cases endodontically or surgically. Development of techniques, instruments and root medicaments as well as the tendency toward minimally invasive treatment, all support dentists to treat those cases using the minimal invasive principle (i.e. endodontically instead of surgically. Purpose: The purpose of this paper is to report and discuss the managing of periapical lesions by endodontic no invasive treatment. Case management: The patient with large periapical lesions were treated with noninvasive endodontic treatment. After 6 months, patients in this report were asymptomatic and radiolucencies had disappeared. When the root canal treatment is done according to accepted clinical principles and under aseptic condition, including cleaning, shaping, abturating as well as proper diagnosis, the healing process of the infected area will occur. Conclusion: Some lesions, however, may not be treated conservatively and may require surgical treatment for total elimination of the lesions.

  15. A neural network model for non invasive subsurface stratigraphic identification

    International Nuclear Information System (INIS)

    Sullivan, John M. Jr.; Ludwig, Reinhold; Lai Qiang

    2000-01-01

    Ground-Penetrating Radar (GRP) is a powerful tool to examine the stratigraphy below ground surface for remote sensing. Increasingly GPR has also found applications in microwave NDE as an interrogation tool to assess dielectric layers. Unfortunately, GPR data is characterized by a high degree of uncertainty and natural physical ambiguity. Robust decomposition routines are sparse for this application. We have developed a hierarchical set of neural network modules which split the task of layer profiling into consecutive stages. Successful GPR profiling of the subsurface stratigraphy is of key importance for many remote sensing applications including microwave NDE. Neural network modules were designed to accomplish the two main processing goals of recognizing the 'subsurface pattern' followed by the identification of the depths of the subsurface layers like permafrost, groundwater table, and bedrock. We used an adaptive transform technique to transform raw GPR data into a small feature vector containing the most representative and discriminative features of the signal. This information formed the input for the neural network processing units. This strategy reduced the number of required training samples for the neural network by orders of magnitude. The entire processing system was trained using the adaptive transformed feature vector inputs and tested with real measured GPR data. The successful results of this system establishes the feasibility the feasibility of delineating subsurface layering nondestructively

  16. Non-Invasive Measurement of Pulsatile Intracranial Pressures Using Ultrasound

    Science.gov (United States)

    Ueno, Toshiaki; Ballard, Richard E.; Shuer, Lawrence M.; Cantrell, John H.; Cantrell, John H.; Hargens, Alan R.

    1997-01-01

    Early detection of elevated intracranial pressure (ICP) will aid clinical decision-making for head trauma, brain tumor and other cerebrovascular diseases. Conventional methods, however, require surgical procedures which take time and are accompanied by increased risk of infection. Accordingly we have developed and refined a new ultrasound device to measure skull movements which are known to occur in conjunction with altered ICP. The principle of this device is based upon pulse phase locked loop (PPLL), which enables us to detect changes in distance on the order of microns between an ultrasound transducer on one side of the skull and the opposite inner surface of the cranium. The present study was designed to verify this measurement technique in cadavera. Transcranial distance was increased in steps of 10 mmHg from zero to 50 mmHg by saline infusion into the lateral ventricle of two cadavera. In separate experiments, pulsations of ICP with the amplitudes of zero to 2 mmHg were generated by rhythmic injections of saline using a syringe. When the ICP was stepwise increased from zero to 50 mmHg, transcranial distance increased in proportion with the ICP increase (y=12 x - 76, r=0.938), where y is changes in transcranial distance in microns and x is ICP in mmHg. In the data recorded while ICP pulsations were generated, fast Fourier transform analysis demonstrated that cranial pulsations were clearly associated with ICP pulsations. The results indicate that changes in transcranial distance is linearly correlated with those in ICP, and also that the PPLL device has sufficient sensitivity to detect transcranial pulsations which occur in association with the cardiac cycle. By analyzing the magnitude of cranial pulsations, we may be able to estimate the pressure-volume index in the cranium. As a result, estimates of intracranial compliance may be possible by using the PPLL device. Further studies are necessary in normal subjects and patients.

  17. Osteopontin: A non-invasive parameter of portal hypertension and prognostic marker of cirrhosis.

    Science.gov (United States)

    Bruha, Radan; Jachymova, Marie; Petrtyl, Jaromir; Dvorak, Karel; Lenicek, Martin; Urbanek, Petr; Svestka, Tomislav; Vitek, Libor

    2016-03-28

    To investigate the relationship between osteopontin plasma concentrations and the severity of portal hypertension and to assess osteopontin prognostic value. A cohort of 154 patients with confirmed liver cirrhosis (112 ethylic, 108 men, age 34-72 years) were enrolled in the study. Hepatic venous pressure gradient (HVPG) measurement and laboratory and ultrasound examinations were carried out for all patients. HVPG was measured using a standard catheterization method with the balloon wedge technique. Osteopontin was measured using the enzyme-linked immunosorbent assay (ELISA) method in plasma. Patients were followed up with a specific focus on mortality. The control group consisted of 137 healthy age- and sex- matched individuals. The mean value of HVPG was 16.18 ± 5.6 mmHg. Compared to controls, the plasma levels of osteopontin in cirrhotic patients were significantly higher (P portal hypertension (HVPG above 10 mmHg) at 75% sensitivity and 63% specificity. The mean follow-up of patients was 3.7 ± 2.6 years. The probability of cumulative survival was 39% for patients with HVPG > 10 mmHg and 65% for those with HVPG ≤ 10 mmHg (P = 0.0086, odds ratio (OR), 2.92, 95% confidence interval (CI): 1.09-7.76). Osteopontin showed a similar prognostic value to HVPG. Patients with osteopontin values above 80 ng/mL had significantly lower cumulative survival compared to those with osteopontin ≤ 80 ng/mL (37% vs 56%, P = 0.00035; OR = 2.23, 95%CI: 1.06-4.68). Osteopontin is a non-invasive parameter of portal hypertension that distinguishes patients with clinically significant portal hypertension. It is a strong prognostic factor for survival.

  18. Improvements on a non-invasive, parameter-free approach to inverse form finding

    Science.gov (United States)

    Landkammer, P.; Caspari, M.; Steinmann, P.

    2018-04-01

    Our objective is to determine the optimal undeformed workpiece geometry (material configuration) within forming processes when the prescribed deformed geometry (spatial configuration) is given. For solving the resulting shape optimization problem—also denoted as inverse form finding—we use a novel parameter-free approach, which relocates in each iteration the material nodal positions as design variables. The spatial nodal positions computed by an elasto-plastic finite element (FE) forming simulation are compared with their prescribed values. The objective function expresses a least-squares summation of the differences between the computed and the prescribed nodal positions. Here, a recently developed shape optimization approach (Landkammer and Steinmann in Comput Mech 57(2):169-191, 2016) is investigated with a view to enhance its stability and efficiency. Motivated by nonlinear optimization theory a detailed justification of the algorithm is given. Furthermore, a classification according to shape changing design, fixed and controlled nodal coordinates is introduced. Two examples with large elasto-plastic strains demonstrate that using a superconvergent patch recovery technique instead of a least-squares (L2)-smoothing improves the efficiency. Updating the interior discretization nodes by solving a fictitious elastic problem also reduces the number of required FE iterations and avoids severe mesh distortions. Furthermore, the impact of the inclusion of the second deformation gradient in the Hessian of the Quasi-Newton approach is analyzed. Inverse form finding is a crucial issue in metal forming applications. As a special feature, the approach is designed to be coupled in a non-invasive fashion to arbitrary FE software.

  19. Non-invasive multiparametric qBOLD approach for robust mapping of the oxygen extraction fraction.

    Science.gov (United States)

    Domsch, Sebastian; Mie, Moritz B; Wenz, Frederik; Schad, Lothar R

    2014-09-01

    The quantitative blood oxygenation level-dependent (qBOLD) method has not become clinically established yet because long acquisition times are necessary to achieve an acceptable certainty of the parameter estimates. In this work, a non-invasive multiparametric (nimp) qBOLD approach based on a simple analytical model is proposed to facilitate robust oxygen extraction fraction (OEF) mapping within clinically acceptable acquisition times by using separate measurements. The protocol consisted of a gradient-echo sampled spin-echo sequence (GESSE), a T2-weighted Carr-Purcell-Meiboom-Gill (CPMG) sequence, and a T2(*)-weighted multi-slice multi-echo gradient echo (MMGE) sequence. The GESSE acquisition time was less than 5 minutes and the extra measurement time for CPMG/MMGE was below 2 minutes each. The proposed nimp-qBOLD approach was validated in healthy subjects (N = 5) and one patient. The proposed nimp-qBOLD approach facilitated more robust OEF mapping with significantly reduced inter- and intra-subject variability compared to the standard qBOLD method. Thereby, an average OEF in all subjects of 27±2% in white matter (WM) and 29±2% in gray matter (GM) using the nimp-qBOLD method was more stable compared to 41±10% (WM) and 46±10% (GM) with standard qBOLD. Moreover, the spatial variance in the image slice (i.e. standard deviation divided by mean) was on average reduced from 35% to 25%. In addition, the preliminary results of the patient are encouraging. The proposed nimp-qBOLD technique provides a promising tool for robust OEF mapping within clinically acceptable acquisition times and could therefore provide an important contribution for analyzing tumors or monitoring the success of radio and chemo therapies. Copyright © 2014. Published by Elsevier GmbH.

  20. Non-invasive brain stimulation enhances the effects of Melodic Intonation Therapy

    Directory of Open Access Journals (Sweden)

    Bradley W. Vines

    2011-09-01

    Full Text Available Research has suggested that a fronto-temporal network in the right hemisphere may be responsible for mediating Melodic Intonation Therapy’s positive effects on speech recovery. We investigated the potential for a non-invasive brain stimulation technique, transcranial direct current stimulation (tDCS, to augment the benefits of MIT in patients with non-fluent aphasia by modulating neural activity in the brain during treatment with MIT. The polarity of the current applied to the scalp determines the effects of tDCS on the underlying tissue: anodal tDCS increases excitability, whereas cathodal tDCS decreases excitability. We applied anodal tDCS to the posterior inferior frontal gyrus (IFG of the right hemisphere, an area that has been shown to both contribute to singing through the mapping of sounds to ariculatory actions and serve as a key region in the process of recovery from aphasia, particularly in patients with large left hemispheric lesions. The stimulation was applied while patients were treated with MIT by a trained therapist. Six patients with moderate to severe non-fluent aphasia underwent three consecutive days of anodal-tDCS+MIT, and an equivalent series of sham-tDCS+MIT. The two treatment series were separated by one week, and the order in which the treatments were administered was randomized. Compared to the effects of sham-tDCS+MIT, anodal-tDCS+MIT led to significant improvements in fluency of speech. These results support the hypothesis that, as the brain seeks to reorganize and compensate for damage to left-hemisphere language centers, combining anodal-tDCS with MIT may further recovery from post-stroke aphasia by enhancing activity in a right-hemisphere sensorimotor network for articulation.

  1. Plasma surface reflectance spectroscopy for non-invasive and continuous monitoring of extracellular component of blood

    Science.gov (United States)

    Sakota, Daisuke; Takatani, Setsuo

    2012-04-01

    To achieve the quantitative optical non-invasive diagnosis of blood during extracorporeal circulation therapies, the instrumental technique to extract extracellular spectra from whole blood was developed. In the circuit, the continuous blood flow was generated by a centrifugal blood pump. The oxygen saturation was maintained 100% by an oxygenator. The developed glass optical flow cell was attached to the outlet tubing of the oxygenator. The halogen lamp including the light from 400 to 900 nm wavelength was used for the light source. The light was guided into an optical fiber. The light emitted by the fiber was collimated and emitted to the flow cell flat surface at the incident angle of 45 degrees. The light just reflected on the boundary between inner surface of the flow cell and plasma at 45 degrees was detected by the detection fiber. The detected light was analyzed by a spectral photometer. The obtained spectrum from 400 to 600nm wavelength was not changed with respect to the hematocrit. In contrast, the signal in the spectral range was changed when the plasma free hemoglobin increased. By using two spectral range, 505+/-5 nm and 542.5+/-2.5 nm, the differential spectrum was correlated with the free hemoglobin at R2=0.99. On the other hand, as for the hematocrit, the differential spectrum was not correlated at R2=0.01. Finally, the plasma free hemoglobin was quantified with the accuracy of 22+/-19mg/dL. The result shows that the developed plasma surface reflectance spectroscopy (PSRS) can extract the plasma spectrum from flowing whole blood.

  2. NON-INVASIVE SURVEY OF OLD PAINTINGS USING VNIR HYPERSPECTRAL SENSOR

    Directory of Open Access Journals (Sweden)

    E. Matouskova

    2013-07-01

    Full Text Available Hyperspectral imaging is relatively new method developed primarily for army applications with respect to detection of possible chemical weapon existence and as an efficient assistant for a geological survey. The method is based on recording spectral profile for many hundreds of narrow spectral band. The technique gives full spectral curve of explored pixel which is an unparalleled signature of pixels material. Spectral signatures can then be compared with pre-defined spectral libraries or they can be created with respect to application. A new project named "New Modern Methods of Non-invasive Survey of Historical Site Objects" started at CTU in Prague with the New Year. The project is designed for 4 years and is funded by the Ministry of Culture in the Czech Republic. It is focused on material and chemical composition, damage diagnostics, condition description of paintings, images, construction components and whole structure object analysis in cultural heritage domain. This paper shows first results of the project on painting documentation field as well as used instrument. Hyperspec VNIR by Headwall Photonics was used for this analysis. It operates in the spectral range between 400 and 1000 nm. Comparison with infrared photography is discussed. The goal of this contribution is a non-destructive deep exploration of specific paintings. Two original 17th century paintings by Flemish authors Thomas van Apshoven ("On the Road" and David Teniers the Younger ("The Interior of a Mill" were chosen for the first analysis with a kind permission of academic painter Mr. M. Martan. Both paintings oil painted on wooden panel. This combination was chosen because of the possibility of underdrawing visualization which is supposed to be the most uncomplicated painting combination for this type of analysis.

  3. A new method for non-invasive estimation of human muscle fiber type composition.

    Directory of Open Access Journals (Sweden)

    Audrey Baguet

    Full Text Available BACKGROUND: It has been established that excellence in sports with short and long exercise duration requires a high proportion of fast-twitch (FT or type-II fibers and slow-twitch (ST or type-I fibers, respectively. Until today, the muscle biopsy method is still accepted as gold standard to measure muscle fiber type composition. Because of its invasive nature and high sampling variance, it would be useful to develop a non-invasive alternative. METHODOLOGY: Eighty-three control subjects, 15 talented young track-and-field athletes, 51 elite athletes and 14 ex-athletes volunteered to participate in the current study. The carnosine content of all 163 subjects was measured in the gastrocnemius muscle by proton magnetic resonance spectroscopy ((1H-MRS. Muscle biopsies for fiber typing were taken from 12 untrained males. PRINCIPAL FINDINGS: A significant positive correlation was found between muscle carnosine, measured by (1H-MRS, and percentage area occupied by type II fibers. Explosive athletes had ∼30% higher carnosine levels compared to a reference population, whereas it was ∼20% lower than normal in typical endurance athletes. Similar results were found in young talents and ex-athletes. When active elite runners were ranked according to their best running distance, a negative sigmoidal curve was found between logarithm of running distance and muscle carnosine. CONCLUSIONS: Muscle carnosine content shows a good reflection of the disciplines of elite track-and-field athletes and is able to distinguish between individual track running distances. The differences between endurance and sprint muscle types is also observed in young talents and former athletes, suggesting this characteristic is genetically determined and can be applied in early talent identification. This quick method provides a valid alternative for the muscle biopsy method. In addition, this technique may also contribute to the diagnosis and monitoring of many conditions and

  4. Clinical review: Helmet and non-invasive mechanical ventilation in critically ill patients.

    Science.gov (United States)

    Esquinas Rodriguez, Antonio M; Papadakos, Peter J; Carron, Michele; Cosentini, Roberto; Chiumello, Davide

    2013-04-25

    Non-invasive mechanical ventilation (NIV) has proved to be an excellent technique in selected critically ill patients with different forms of acute respiratory failure. However, NIV can fail on account of the severity of the disease and technical problems, particularly at the interface. The helmet could be an alternative interface compared to face mask to improve NIV success. We performed a clinical review to investigate the main physiological and clinical studies assessing the efficacy and related issues of NIV delivered with a helmet. A computerized search strategy of MEDLINE/PubMed (January 2000 to May 2012) and EMBASE (January 2000 to May 2012) was conducted limiting the search to retrospective, prospective, nonrandomized and randomized trials. We analyzed 152 studies from which 33 were selected, 12 physiological and 21 clinical (879 patients). The physiological studies showed that NIV with helmet could predispose to CO₂ rebreathing and increase the patients' ventilator asynchrony. The main indications for NIV were acute cardiogenic pulmonary edema, hypoxemic acute respiratory failure (community-acquired pneumonia, postoperative and immunocompromised patients) and hypercapnic acute respiratory failure. In 9 of the 21 studies the helmet was compared to a face mask during either continous positive airway pressure or pressure support ventilation. In eight studies oxygenation was similar in the two groups, while the intubation rate was similar in four and lower in three studies for the helmet group compared to face mask group. The outcome was similar in six studies. The tolerance was better with the helmet in six of the studies. Although these data are limited, NIV delivered by helmet could be a safe alternative to the face mask in patients with acute respiratory failure.

  5. Non-invasive multiparametric qBOLD approach for robust mapping of the oxygen extraction fraction

    Energy Technology Data Exchange (ETDEWEB)

    Domsch, Sebastian; Mie, Moritz B.; Schad, Lothar R. [Heidelberg Univ., Medical Faculty Mannheim (Germany). Computer Assisted Clinical Medicine; Wenz, Frederik [Heidelberg Univ., Medical Faculty Mannheim (Germany). Dept. of Radiation Oncology

    2014-10-01

    Introduction: The quantitative blood oxygenation level-dependent (qBOLD) method has not become clinically established yet because long acquisition times are necessary to achieve an acceptable certainty of the parameter estimates. In this work, a non-invasive multiparametric (nimp) qBOLD approach based on a simple analytical model is proposed to facilitate robust oxygen extraction fraction (OEF) mapping within clinically acceptable acquisition times by using separate measurements. Methods: The protocol consisted of a gradient-echo sampled spin-echo sequence (GESSE), a T{sub 2}-weighted Carr-Purcell-Meiboom-Gill (CPMG) sequence, and a T{sub 2}{sup *}-weighted multi-slice multi-echo gradient echo (MMGE) sequence. The GESSE acquisition time was less than 5 minutes and the extra measurement time for CPMG / MMGE was below 2 minutes each. The proposed nimp-qBOLD approach was validated in healthy subjects (N = 5) and one patient. Results: The proposed nimp-qBOLD approach facilitated more robust OEF mapping with significantly reduced inter- and intra-subject variability compared to the standard qBOLD method. Thereby, an average OEF in all subjects of 27 ± 2 % in white matter (WM) and 29 ± 2 % in gray matter (GM) using the nimp-qBOLD method was more stable compared to 41 ± 10 % (WM) and 46 ± 10 % (GM) with standard qBOLD. Moreover, the spatial variance in the image slice (i.e. standard deviation divided by mean) was on average reduced from 35 % to 25 %. In addition, the preliminary results of the patient are encouraging. Conclusion: The proposed nimp-qBOLD technique provides a promising tool for robust OEF mapping within clinically acceptable acquisition times and could therefore provide an important contribution for analyzing tumors or monitoring the success of radio and chemo therapies. (orig.)

  6. Non-invasive brain stimulation for fine motor improvement after stroke: a meta-analysis.

    Science.gov (United States)

    O'Brien, A T; Bertolucci, F; Torrealba-Acosta, G; Huerta, R; Fregni, F; Thibaut, A

    2018-05-09

    The aim of this study was to determine whether non-invasive brain stimulation (NIBS) techniques improve fine motor performance in stroke. We searched PubMed, EMBASE, Web of Science, SciELO and OpenGrey for randomized clinical trials on NIBS for fine motor performance in stroke patients and healthy participants. We computed Hedges' g for active and sham groups, pooled data as random-effects models and performed sensitivity analysis on chronicity, montage, frequency of stimulation and risk of bias. Twenty-nine studies (351 patients and 152 healthy subjects) were reviewed. Effect sizes in stroke populations for transcranial direct current stimulation and repeated transcranial magnetic stimulation were 0.31 [95% confidence interval (CI), 0.08-0.55; P = 0.010; Tau 2 , 0.09; I 2 , 34%; Q, 18.23; P = 0.110] and 0.46 (95% CI, 0.00-0.92; P = 0.05; Tau 2 , 0.38; I 2 , 67%; Q, 30.45; P = 0.007). The effect size of non-dominant healthy hemisphere transcranial direct current stimulation on non-dominant hand function was 1.25 (95% CI, 0.09-2.41; P = 0.04; Tau 2 , 1.26; I 2 , 93%; Q, 40.27; P < 0.001). Our results show that NIBS is associated with gains in fine motor performance in chronic stroke patients and healthy subjects. This supports the effects of NIBS on motor learning and encourages investigation to optimize their effects in clinical and research settings. © 2018 EAN.

  7. Improved Geologic Interpretation of Non-invasive Electrical Resistivity Imaging from In-situ Samples

    Science.gov (United States)

    Mucelli, A.; Aborn, L.; Jacob, R.; Malusis, M.; Evans, J.

    2016-12-01

    Non-invasive geophysical techniques are useful in characterizing the subsurface geology without disturbing the environment, however, the ability to interpret the subsurface is enhanced by invasive work. Since geologic materials have electrical resistivity values it allows for a geologic interpretation to be made based on variations of electrical resistivity measured by electrical resistivity imaging (ERI). This study focuses on the pre-characterization of the geologic subsurface from ERI collected adjacent to the Montandon Marsh, a wetland located near Lewisburg, PA within the West Branch of the Susquehanna River watershed. The previous invasive data, boreholes, indicate that the subsurface consists of limestone and shale bedrock overlain with sand and gravel deposits from glacial outwash and aeolian processes. The objective is to improve our understanding of the subsurface at this long-term hydrologic research site by using excavation results, specifically observed variations in geologic materials and electrical resistivity laboratory testing of subsurface samples. The pre-excavation ERI indicated that the shallow-most geologic material had a resistivity value of 100-500 ohm-m. In comparison, the laboratory testing indicated the shallow-most material had the same range of electrical resistivity values depending on saturation levels. The ERI also showed that there was an electrically conductive material, 7 to 70 ohm-m, that was interpreted to be clay and agreed with borehole data, however, the excavation revealed that at this depth range the geologic material varied from stratified clay to clay with cobbles to weathered residual clay. Excavation revealed that the subtle variations in the electrical conductive material corresponded well with the variations in the geologic material. We will use these results to reinterpret previously collected ERI data from the entire long-term research site.

  8. Non-invasive assessment of radiation injury with electrical impedance spectroscopy

    International Nuclear Information System (INIS)

    Osterman, K Sunshine; Hoopes, P Jack; De Lorenzo, Christine; Gladstone, David J; Paulsen, Keith D

    2004-01-01

    A detailed understanding of non-targeted normal tissue response is necessary for the optimization of radiation treatment plans in cancer therapy. In this study, we evaluate the ability of electrical impedance spectroscopy (EIS) to non-invasively determine and quantify the injury response in soft tissue after high dose rate (HDR) irradiation, which is characterized by large localized dose distributions possessing steep spatial gradients. The HDR after-loading technique was employed to irradiate small volumes of muscle tissue with single doses (26-52 Gy targeted 5 mm away from the source). Impedance measurements were performed on 29 rats at 1, 2 and 3 month post-irradiation, employing 31 frequencies in the 1 kHz to 1 MHz range. Over the first 3 months, conductivity increased by 48% and 26% following target doses of 52 Gy and 26 Gy 5 mm from the HDR source, respectively. Injury, assessed independently through a grid-based scoring method showed a quadratic dependence on distance from source. A significant injury (50% of cells atrophied, necrotic or degenerating) in 1.2% of the volume, accompanied by more diffuse injury (25% of cells atrophied, necrotic or degenerating) in 9% of the tissue produced a conductivity increase of 0.02 S m -1 (8% over a baseline of 0.24 S m -1 ). This was not statistically significant at p 0.01. Among treatment groups, injury differences in 22% of the volume led to statistically significant differences in conductivity of 0.07 S m -1 (23% difference in conductivity). Despite limitations, the success of EIS in detecting responses in a fraction of the tissue probed, during these early post-irradiation time-points, is encouraging. Electrical impedance spectroscopy may provide a useful metric of atrophy and the development of fibrosis secondary to radiation that could be further developed into a low-cost imaging method for radiotherapy monitoring and assessment

  9. Combination of the non-invasive tests for the diagnosis of endometriosis

    NARCIS (Netherlands)

    Nisenblat, Vicki; Prentice, Lucy; Bossuyt, Patrick M. M.; Farquhar, Cindy; Hull, M. Louise; Johnson, Neil

    2016-01-01

    Background About 10% of women of reproductive age suffer from endometriosis, a costly chronic disease causing pelvic pain and subfertility. Laparoscopy is the gold standard diagnostic test for endometriosis, but is expensive and carries surgical risks. Currently, there are no non-invasive tests

  10. Updated Scar Management Practical Guidelines: Non-invasive and invasive measures

    NARCIS (Netherlands)

    Monstrey, S.; Middelkoop, E.; Vranckx, J.J.; Bassetto, F.; Ziegler, U.E.; Meaume, S.; Teot, L.

    2014-01-01

    Hypertrophic scars and keloids can be aesthetically displeasing and lead to severe psychosocial impairment. Many invasive and non-invasive options are available for the plastic (and any other) surgeon both to prevent and to treat abnormal scar formation. Recently, an updated set of practical

  11. Research Report Non-invasive DNA-based species and sex ...

    Indian Academy of Sciences (India)

    shrushti modi

    Non-invasive DNA-based species and sex identification of Asiatic wild dog (Cuon alpinus) .... We did not find any cross-gender amplification with any of the reference or field-collected samples. Success rate for sex discrimination for all field-.

  12. Non-invasive electrical and magnetic stimulation of the brain, spinal cord, roots and peripheral nerves

    DEFF Research Database (Denmark)

    Rossini, P M; Burke, D; Chen, R

    2015-01-01

    These guidelines provide an up-date of previous IFCN report on "Non-invasive electrical and magnetic stimulation of the brain, spinal cord and roots: basic principles and procedures for routine clinical application" (Rossini et al., 1994). A new Committee, composed of international experts, some...

  13. miRandola 2017: a curated knowledge base of non-invasive biomarkers

    DEFF Research Database (Denmark)

    Russo, Francesco; Di Bella, Sebastiano; Vannini, Federica

    2018-01-01

    miRandola (http://mirandola.iit.cnr.it/) is a database of extracellular non-coding RNAs (ncRNAs) that was initially published in 2012, foreseeing the relevance of ncRNAs as non-invasive biomarkers. An increasing amount of experimental evidence shows that ncRNAs are frequently dysregulated in dise...

  14. Epidemiological aspects of recruitment of male volunteers for non-invasive urodynamics

    NARCIS (Netherlands)

    V. Avagyan (Vardan); R. van Mastrigt (Ron); J.W.N.C. Huang Foen Chung (John); A.M. Bohnen (Arthur); P.G.H. Mulder (Paul); J.L.H.R. Bosch (Ruud)

    2006-01-01

    textabstractWe studied epidemiological aspects of recruitment of volunteers for a non-invasive urodynamic study. MATERIALS AND METHODS: 9,236 volunteers were invited by 20 general practitioners (GPs), using two different recruitment methods, i.e. by mail only, or during a

  15. Comparative anatomy of invasive and non-invasive species in the ...

    African Journals Online (AJOL)

    The foliar and stem micromorphological study of the invasive and non-invasive species were undertaken using Light Microscope (LM). The occurrence of vessels in the pillar of the abundant sclerenchyma tissues are important component of the skeletal system in the invasive species. The prominent tiles of parenchymatous ...

  16. The management of non-invasive bladder tumours with Doxorubicin intravesical instillation after transurethral resection.

    Science.gov (United States)

    Al-Gallab, Musa I; Naddaf, Louai A; Kanan, Mohamad R

    2009-04-01

    Evaluation of the intravesical instillation of doxorubicin for its effect on disease recurrence for patients with non-invasive bladder tumour. The study was performed at Al Assad University Hospital in Lattakia, Syria and included patients with non-invasive bladder tumours who were managed with transurethral resection and induction and maintenance therapy with intravesical doxorubicin. They were followed up by cystoscopy every 3 months for 2 years and every 6 months thereafter with special emphasis on recurrence rates. The study included 85 patients with non-invasive bladder tumours: 23 with non-invasive papillary carcinoma (Stage Ta), 62 with tumour invading subepithelial connective tissue (Stage T1). Twelve patients had well differentiated tumours (Grade 1), 48 had moderately differentiated (Grade 2), 25 had poorly differentiated (Grade 3) tumours. The total recurrence rate was 23%. The rates of recurrence were 56% in Grade 3 and 0% in Grade 1. The recurrence rate was 41% in patients with large tumours versus 17% in those with small tumours; 44% in those with multiple tumours compared to 18% in those with solitary tumours; 30% of Stage Ta tumours recurred and 21% of Stage T1 tumours. In short term follow-up, our rate of recurrence was 23%. Adjuvant intravesical doxorubicin was shown to reduce the recurrence of superficial bladder cancer. Tumour grade, size and number were shown to be prognostic factors for recurrence.

  17. Ultraweak photon emission as a non-invasive health assessment: A systematic review

    NARCIS (Netherlands)

    Ives, J.A.; Wijk, E.P.A. van; Bat, N.; Crawford, C.; Walter, A.; Jonas, W.B.; Wijk, R. van; Greef, J. van der

    2014-01-01

    We conducted a systematic review (SR) of the peer reviewed scientific literature on ultraweak photon emissions (UPE) from humans. The question was: Can ultraweak photon emissions from humans be used as a non-invasive health assessment? A systematic search was conducted across eight relevant

  18. Non-invasive prenatal testing for sub-saharan Africa: Tailoring ...

    African Journals Online (AJOL)

    BACKGROUND Non-invasive prenatal testing (NIPT) for cell-free foetal (cff) RHD genotyping has clinical value to guide pregnancy management for alloimmunised RhD-negative pregnant women and guide antenatal anti-D prophylaxis needs for all D-negative women to prevent alloimmunisation. This assay assumes there ...

  19. Non-invasive ambient pressure estimation using non-linear ultrasound contrast agents

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup

    Many attempts to find a non-invasive procedure to measure the blood pressure locally in the body have been made. This dissertation focuses on the approaches which utilize highly compressible ultrasound contrast agents as ambient pressure sensors. The literature within the topic has been reviewed...

  20. Evaluation of non-invasive trunk sprays and trunk-injected emamectic benzoate

    Science.gov (United States)

    Deborah G. McCullough; D.L. Cappaert; T.M. Poland; A.C. Anulewicz; P. Lewis; J. Molongoski

    2008-01-01

    In 2007, we continued to evaluate two neo-nicotinoid insecticides, imidacloprid and dinotefuron, applied as non-invasive trunk sprays to control emerald ash borer (EAB), Agrilus planipennis Fairmaire. Neo-nicotinoid products are widely used to protect landscape ash trees because they are relatively safe for humans and non-target species. These...

  1. The predictive value of respiratory function tests for non-invasive ventilation in amyotrophic lateral sclerosis

    NARCIS (Netherlands)

    Tilanus, T.B.M.; Groothuis, J.T.; Broek-Pastoor, J.M.C. ten; Feuth, T.; Heijdra, Y.F.; Slenders, J.P.L.; Doorduin, J.; Engelen, B.G.M. van; Kampelmacher, M.J.; Raaphorst, J.

    2017-01-01

    BACKGROUND: Non-invasive ventilation (NIV) improves survival and quality of life in amyotrophic lateral sclerosis (ALS) patients. The timing of referral to a home ventilation service (HVS), which is in part based on respiratory function tests, has shown room for improvement. It is currently unknown

  2. The predictive value of respiratory function tests for non-invasive ventilation in amyotrophic lateral sclerosis

    NARCIS (Netherlands)

    Tilanus, T. B. M.; Groothuis, J. T.; TenBroek-Pastoor, J. M. C.; Feuth, T. B.; Heijdra, Y. F.; Slenders, J. P. L.; Doorduin, J.; van Engelen, B. G.; Kampelmacher, M. J.; Raaphorst, J.

    2017-01-01

    Background: Non-invasive ventilation (NIV) improves survival and quality of life in amyotrophic lateral sclerosis (ALS) patients. The timing of referral to a home ventilation service (HVS), which is in part based on respiratory function tests, has shown room for improvement. It is currently unknown

  3. Application of quantum dot nanoparticles for potential non-invasive bio-imaging of mammalian spermatozoa

    Science.gov (United States)

    Various obstacles are encountered by mammalian spermatozoa during their journey through the female genital tract, and only few or none will reach the site of fertilization. Currently, there are limited technical approaches for non-invasive investigation of spermatozoa migration after insemination. A...

  4. Development of non-invasive ventilation treatment practice for patients with chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Christensen, Helle M; Titlestad, Ingrid L; Huniche, Lotte

    2017-01-01

    Objectives: Non-invasive ventilation treatment for patients with acute exacerbation of chronic obstructive pulmonary disease is well documented. Communication with patients during treatment is inhibited because of the mask, the noise from the machine and patient distress. Assessing life expectanc...

  5. Non-drug Non-invasive Treatment in the Management of Low Back ...

    African Journals Online (AJOL)

    ... of functional independence and quality of life. Aim: The main purpose of this study was to assess the results of non-drug non-invasive treatment in the management of LBP. Subjects and Methods: This was prospective study conducted in the Department of Orthopedics in M. M. Medical College, Mullana, Ambala, Haryana, ...

  6. Bridging the gaps between non-invasive genetic sampling and population parameter estimation

    Science.gov (United States)

    Francesca Marucco; Luigi Boitani; Daniel H. Pletscher; Michael K. Schwartz

    2011-01-01

    Reliable estimates of population parameters are necessary for effective management and conservation actions. The use of genetic data for capture­recapture (CR) analyses has become an important tool to estimate population parameters for elusive species. Strong emphasis has been placed on the genetic analysis of non-invasive samples, or on the CR analysis; however,...

  7. Non-invasive monitoring of pharmacokinetics and pharmacodynamics for pharmacological drug profiling in children and adolescents

    NARCIS (Netherlands)

    Schrier, Lenneke

    2015-01-01

    This thesis describes the potential role of non-invasive measurement of pharmacokinetics (pk) and pharmacodynamics (pd) in the research and development of central nervous system (cns) stimulants or depressants for children and adolescents. First, we evaluated the feasibility of using saliva as an

  8. The relation between invasive and non-invasive tear break-up time ...

    African Journals Online (AJOL)

    Tear stability normal to Nigerians with consideration of gender and age has not been reported. Tear stability in young adults was measured using invasive and non-invasive tear break-up time (TBUT and NIBUT). Forty –five subjects aged 20 to 30 years were selected from among the students of University of. Benin, Edo ...

  9. Non-Invasive Ventilation in Patients with Heart Failure: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Bittencourt, Hugo Souza; Reis, Helena França Correia Dos; Lima, Melissa Santos; Gomes, Mansueto

    2017-02-01

    Non-invasive ventilation (NIV) may perfect respiratory and cardiac performance in patients with heart failure (HF). The objective of the study to establish, through systematic review and meta-analysis, NIV influence on functional capacity of HF patients. A systematic review with meta-analysis of randomized studies was carried out through research of databases of Cochrane Library, SciELO, Pubmed and PEDro, using the key-words: heart failure, non-invasive ventilation, exercise tolerance; and the free terms: bi-level positive airway pressure (BIPAP), continuous positive airway pressure (CPAP), and functional capacity (terms were searched for in English and Portuguese) using the Boolean operators AND and OR. Methodological quality was ensured through PEDro scale. Weighted averages and a 95% confidence interval (CI) were calculated. The meta-analysis was done thorugh the software Review Manager, version 5.3 (Cochrane Collaboration). Four randomized clinical trials were included. Individual studies suggest NIV improved functional capacity. NIV resulted in improvement in the distance of the six-minute walk test (6MWT) (68.7m 95%CI: 52.6 to 84.9) in comparison to the control group. We conclude that the NIV is an intervention that promotes important effects in the improvement of functional capacity of HF patients. However, there is a gap in literature on which are the most adequate parameters for the application of this technique. Resumo A ventilação não invasiva (VNI) pode aperfeiçoar o desempenho cardíaco e respiratório dos pacientes com insuficiência cardíaca (IC). O objetivo do estudo é estabelecer, por meio de revisão sistemática e meta-análise, a influência da VNI na capacidade funcional (CF) de indivíduos com IC. Foi realizada uma revisão sistemática com meta-análise de estudos randomizados através da pesquisa nas bases de dados Biblioteca Cochrane, SciELO, Pubmed e PEDro, utilizando-se as palavras-chave: insuficiência cardíaca, ventilação n

  10. Non-invasive Field Measurements of Soil Water Content Using a Pulsed 14 MeV Neutron Generator

    Energy Technology Data Exchange (ETDEWEB)

    Mitra S.; Wielopolski L.; Omonode, R.; Novak, J.; Frederick, J.; Chan, A.

    2012-01-26

    Current techniques of soil water content measurement are invasive and labor-intensive. Here, we demonstrate that an in situ soil carbon (C) analyzer with a multi-elemental analysis capability, developed for studies of terrestrial C sequestration, can be used concurrently to non-invasively measure the water content of large-volume ({approx}0.3 m{sup 3}) soil samples. Our objectives were to investigate the correlations of the hydrogen (H) and oxygen (O) signals with water to the changes in the soil water content in laboratory experiments, and in an agricultural field. Implementing prompt gamma neutron activation analyses we showed that in the field, the signal from the H nucleus better indicates the soil water content than does that from the O nucleus. Using a field calibration, we were able to use the H signal to estimate a minimum detectable change of {approx}2% volumetric water in a 0-30 cm depth of soil.

  11. Distinction between added-energy and phase-resetting mechanisms in non-invasively detected somatosensory evoked responses.

    Science.gov (United States)

    Fedele, T; Scheer, H-J; Burghoff, M; Waterstraat, G; Nikulin, V V; Curio, G

    2013-01-01

    Non-invasively recorded averaged event-related potentials (ERP) represent a convenient opportunity to investigate human brain perceptive and cognitive processes. Nevertheless, generative ERP mechanisms are still debated. Two previous approaches have been contested in the past: the added-energy model in which the response raises independently from the ongoing background activity, and the phase-reset model, based on stimulus-driven synchronization of oscillatory ongoing activity. Many criteria for the distinction of these two models have been proposed, but there is no definitive methodology to disentangle them, owing also to the limited information at the single trial level. Here, we propose a new approach combining low-noise EEG technology and multivariate decomposition techniques. We present theoretical analyses based on simulated data and identify in high-frequency somatosensory evoked responses an optimal target for the distinction between the two mechanisms.

  12. Assessment of non-invasive time and frequency atrial fibrillation organization markers with unipolar atrial electrograms

    International Nuclear Information System (INIS)

    Alcaraz, Raúl; Hornero, Fernando; Rieta, José J

    2011-01-01

    The standard electrocardiogram (ECG) is the most common non-invasive way to study atrial fibrillation (AF). In this respect, previous works have shown that the surface lead V 1 reflects mainly the dominant atrial frequency (DAF) of the right atrium (RA), which has been widely used to study AF. In a similar way, AF organization and fibrillatory (f) wave amplitude are two recently proposed non-invasive AF markers. These markers need to be validated with invasive recordings in order to assess their capability to reliably reflect the internal fibrillatory activity dynamics. In this work, these two non-invasive metrics have been compared with similar measures recorded from two unipolar atrial electrograms (AEGs). For both ECG and AEG signals, AF organization has been computed by applying a nonlinear regularity index, such as sample entropy (SampEn), to the atrial activity (AA) and to its fundamental waveform, defined as the main atrial wave (MAW). The surface and epicardial f wave amplitude has been estimated through their mean power. Results obtained for 38 patients showed statistically significant correlations between the values measured from surface and invasive recordings, thus corroborating the usefulness of the aforesaid markers in the non-invasive study of AF. Precisely, for AF organization computed from the MAW, the correlation coefficients between surface and both AEGs were R = 0.926 (p < 0.001) and R = 0.932 (p < 0.001). For f wave amplitude, slightly lower significant relationships were noticed, the correlation coefficients being R = 0.765 (p < 0.001) and R = 0.842 (p < 0.001). These outcomes together with interesting linear relationships found among the parameters suggest that AF regularity estimated via SampEn and f wave amplitude can non-invasively characterize the epicardial activity related to AF

  13. Non-invasive nursing technologies for pain relief during childbirth--the Brazilian nurse midwives' view.

    Science.gov (United States)

    Vargens, Octavio M C; Silva, Alexandra C V; Progianti, Jane M

    2013-11-01

    to describe the non-invasive care technologies most frequently used by nurse midwives to relieve childbirth pain, and provide a synthesis of studies published by Brazilian nurse midwives on the use of such technologies. a systematic literature review focusing on the non-invasive pain relief strategies used by nurse midwives in Brazil. Surveys of three databases (BDENF, CINAHL and MEDLINE) were conducted between 2002 and 2012. The inclusion criteria were: (1) full-text article available; (2) published between 2002 and 2012; (3) written by Brazilian nurse midwives, and (4) fitting the descriptors: childbirth pain; non-invasive technologies; labour; and pain relief. For purposes of analysis, the technologies mentioned were classified into four main categories of support as they relate to environment, position, tactile stimulation, and energy level. we located 21 scientific articles that met the inclusion criteria and addressed the non-invasive technologies that nurse midwives use to provide pain relief during labour. The technologies most used was: stimulation of breathing and relaxation; use of massage with essential oils; encouraging freedom to move, to walk and the free choice for vertical positioning; use of showers and baths; use of birth ball. Brazilian nurse midwives have made efforts to focus care during delivery on the parturient. By studying and publishing about the non-invasive care technologies they have strengthened de-medicalised knowledge, based on scientific evidence and good outcomes in pain relief during labour. the study presented ideas towards improved theoretical foundations and strategies for establishing practice consonant with humanised care. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Non-Invasive monitoring of diaphragmatic timing by means of surface contact sensors: An experimental study in dogs

    Directory of Open Access Journals (Sweden)

    Galdiz Batxi

    2004-09-01

    Full Text Available Abstract Background Non-invasive monitoring of respiratory muscle function is an area of increasing research interest, resulting in the appearance of new monitoring devices, one of these being piezoelectric contact sensors. The present study was designed to test whether the use of piezoelectric contact (non-invasive sensors could be useful in respiratory monitoring, in particular in measuring the timing of diaphragmatic contraction. Methods Experiments were performed in an animal model: three pentobarbital anesthetized mongrel dogs. The motion of the thoracic cage was acquired by means of a piezoelectric contact sensor placed on the costal wall. This signal is compared with direct measurements of the diaphragmatic muscle length, made by sonomicrometry. Furthermore, to assess the diaphragmatic function other respiratory signals were acquired: respiratory airflow and transdiaphragmatic pressure. Diaphragm contraction time was estimated with these four signals. Using diaphragm length signal as reference, contraction times estimated with the other three signals were compared with the contraction time estimated with diaphragm length signal. Results The contraction time estimated with the TM signal tends to give a reading 0.06 seconds lower than the measure made with the DL signal (-0.21 and 0.00 for FL and DP signals, respectively, with a standard deviation of 0.05 seconds (0.08 and 0.06 for FL and DP signals, respectively. Correlation coefficients indicated a close link between time contraction estimated with TM signal and contraction time estimated with DL signal (a Pearson correlation coefficient of 0.98, a reliability coefficient of 0.95, a slope of 1.01 and a Spearman's rank-order coefficient of 0.98. In general, correlation coefficients and mean and standard deviation of the difference were better in the inspiratory load respiratory test than in spontaneous ventilation tests. Conclusion The technique presented in this work provides a non-invasive

  15. Pulsed cavitational ultrasound for non-invasive chordal cutting guided by real-time 3D echocardiography.

    Science.gov (United States)

    Villemain, Olivier; Kwiecinski, Wojciech; Bel, Alain; Robin, Justine; Bruneval, Patrick; Arnal, Bastien; Tanter, Mickael; Pernot, Mathieu; Messas, Emmanuel

    2016-10-01

    Basal chordae surgical section has been shown to be effective in reducing ischaemic mitral regurgitation (IMR). Achieving this section by non-invasive mean can considerably decrease the morbidity of this intervention on already infarcted myocardium. We investigated in vitro and in vivo the feasibility and safety of pulsed cavitational focused ultrasound (histotripsy) for non-invasive chordal cutting guided by real-time 3D echocardiography. Experiments were performed on 12 sheep hearts, 5 in vitro on explanted sheep hearts and 7 in vivo on beating sheep hearts. In vitro, the mitral valve (MV) apparatus including basal and marginal chordae was removed and fixed on a holder in a water tank. High-intensity ultrasound pulses were emitted from the therapeutic device (1-MHz focused transducer, pulses of 8 µs duration, peak negative pressure of 17 MPa, repetition frequency of 100 Hz), placed at a distance of 64 mm under 3D echocardiography guidance. In vivo, after sternotomy, the same therapeutic device was applied on the beating heart. We analysed MV coaptation and chordae by real-time 3D echocardiography before and after basal chordal cutting. After sacrifice, the MV apparatus were harvested for anatomical and histological post-mortem explorations to confirm the section of the chordae. In vitro, all chordae were completely cut after a mean procedure duration of 5.5 ± 2.5 min. The procedure duration was found to increase linearly with the chordae diameter. In vivo, the central basal chordae of the anterior leaflet were completely cut. The mean procedure duration was 20 ± 9 min (min = 14, max = 26). The sectioned chordae was visible on echocardiography, and MV coaptation remained normal with no significant mitral regurgitation. Anatomical and histological post-mortem explorations of the hearts confirmed the section of the chordae. Histotripsy guided by 3D echo achieved successfully to cut MV chordae in vitro and in vivo in beating heart. We hope that this technique will

  16. Improved non-invasive method for aerosol particle charge measurement employing in-line digital holography

    Science.gov (United States)

    Tripathi, Anjan Kumar

    Electrically charged particles are found in a wide range of applications ranging from electrostatic powder coating, mineral processing, and powder handling to rain-producing cloud formation in atmospheric turbulent flows. In turbulent flows, particle dynamics is influenced by the electric force due to particle charge generation. Quantifying particle charges in such systems will help in better predicting and controlling particle clustering, relative motion, collision, and growth. However, there is a lack of noninvasive techniques to measure particle charges. Recently, a non-invasive method for particle charge measurement using in-line Digital Holographic Particle Tracking Velocimetry (DHPTV) technique was developed in our lab, where charged particles to be measured were introduced to a uniform electric field, and their movement towards the oppositely charged electrode was deemed proportional to the amount of charge on the particles (Fan Yang, 2014 [1]). However, inherent speckle noise associated with reconstructed images was not adequately removed and therefore particle tracking data was contaminated. Furthermore, particle charge calculation based on particle deflection velocity neglected the particle drag force and rebound effect of the highly charged particles from the electrodes. We improved upon the existing particle charge measurement method by: 1) hologram post processing, 2) taking drag force into account in charge calculation, 3) considering rebound effect. The improved method was first fine-tuned through a calibration experiment. The complete method was then applied to two different experiments, namely conduction charging and enclosed fan-driven turbulence chamber, to measure particle charges. In all three experiments conducted, the particle charge was found to obey non-central t-location scale family of distribution. It was also noted that the charge distribution was insensitive to the change in voltage applied between the electrodes. The range of voltage

  17. Precise control of the drug kinetics by means of non-invasive magnetic drug delivery system

    International Nuclear Information System (INIS)

    Chuzawa, M.; Mishima, F.; Akiyama, Y.; Nishijima, S.

    2013-01-01

    Highlights: ► We examined the kinetics of ferromagnetic drugs by simulation. ► We tried to accumulate the magnetic drug in the target part by rotating a magnet. ► Ferromagnetic drugs were accumulated in the target part along the rotating axis. ► Ferromagnetic drugs could be swept downstream in the off-axis part. -- Abstract: In order to solve the problems of the side effects and medical lowering, has been advanced a study on the drug delivery system (DDS) to accumulate the drugs locally in the body with minimum dosage. The DDS is a system that controls the drug kinetics in the body precisely and accumulates the drug locally at the target part, keeping the drugs at high density. Among the DDS, the magnetic drug delivery system (MDDS) is the one that we studied. This is a technique to accumulate drugs by using the magnetic force as the physical driving force. Our previous researches showed the possibility of the technique of MDDS to accumulate the drugs with higher accumulation rate and locality than the traditional methods. It is necessary to apply a strong external magnetic field and a high magnetic gradient to accumulate the ferromagnetic drugs at a deep diseased part non-invasively. However, by applying a static magnetic field from one direction, the drug accumulates only at the surface of the body locates near the magnet. In this study, we tried to change the magnetic field applied by a superconducting bulk magnet with time, in order to make a constant and strong magnetic field applied in the center of the body and to accumulate the ferromagnetic drugs at the deep target part in the body. First of all, the effect of the surface treatment of the ferromagnetic drugs to prevent its absorption in the normal tissue was examined. Then, to increase the accumulation rate of the ferromagnetic drugs at the target part, the distribution of magnetic field was changed, and the optimum spatial and temporal conditions of magnetic field were examined

  18. Non-invasive optical measurement of cerebral metabolism and hemodynamics in infants.

    Science.gov (United States)

    Lin, Pei-Yi; Roche-Labarbe, Nadege; Dehaes, Mathieu; Carp, Stefan; Fenoglio, Angela; Barbieri, Beniamino; Hagan, Katherine; Grant, P Ellen; Franceschini, Maria Angela

    2013-03-14

    Perinatal brain injury remains a significant cause of infant mortality and morbidity, but there is not yet an effective bedside tool that can accurately screen for brain injury, monitor injury evolution, or assess response to therapy. The energy used by neurons is derived largely from tissue oxidative metabolism, and neural hyperactivity and cell death are reflected by corresponding changes in cerebral oxygen metabolism (CMRO₂). Thus, measures of CMRO₂ are reflective of neuronal viability and provide critical diagnostic information, making CMRO₂ an ideal target for bedside measurement of brain health. Brain-imaging techniques such as positron emission tomography (PET) and single-photon emission computed tomography (SPECT) yield measures of cerebral glucose and oxygen metabolism, but these techniques require the administration of radionucleotides, so they are used in only the most acute cases. Continuous-wave near-infrared spectroscopy (CWNIRS) provides non-invasive and non-ionizing radiation measures of hemoglobin oxygen saturation (SO₂) as a surrogate for cerebral oxygen consumption. However, SO₂ is less than ideal as a surrogate for cerebral oxygen metabolism as it is influenced by both oxygen delivery and consumption. Furthermore, measurements of SO₂ are not sensitive enough to detect brain injury hours after the insult, because oxygen consumption and delivery reach equilibrium after acute transients. We investigated the possibility of using more sophisticated NIRS optical methods to quantify cerebral oxygen metabolism at the bedside in healthy and brain-injured newborns. More specifically, we combined the frequency-domain NIRS (FDNIRS) measure of SO2 with the diffuse correlation spectroscopy (DCS) measure of blood flow index (CBFi) to yield an index of CMRO₂ (CMRO₂i). With the combined FDNIRS/DCS system we are able to quantify cerebral metabolism and hemodynamics. This represents an improvement over CWNIRS for detecting brain health, brain

  19. An open-source framework for stress-testing non-invasive foetal ECG extraction algorithms.

    Science.gov (United States)

    Andreotti, Fernando; Behar, Joachim; Zaunseder, Sebastian; Oster, Julien; Clifford, Gari D

    2016-05-01

    Over the past decades, many studies have been published on the extraction of non-invasive foetal electrocardiogram (NI-FECG) from abdominal recordings. Most of these contributions claim to obtain excellent results in detecting foetal QRS (FQRS) complexes in terms of location. A small subset of authors have investigated the extraction of morphological features from the NI-FECG. However, due to the shortage of available public databases, the large variety of performance measures employed and the lack of open-source reference algorithms, most contributions cannot be meaningfully assessed. This article attempts to address these issues by presenting a standardised methodology for stress testing NI-FECG algorithms, including absolute data, as well as extraction and evaluation routines. To that end, a large database of realistic artificial signals was created, totaling 145.8 h of multichannel data and over one million FQRS complexes. An important characteristic of this dataset is the inclusion of several non-stationary events (e.g. foetal movements, uterine contractions and heart rate fluctuations) that are critical for evaluating extraction routines. To demonstrate our testing methodology, three classes of NI-FECG extraction algorithms were evaluated: blind source separation (BSS), template subtraction (TS) and adaptive methods (AM). Experiments were conducted to benchmark the performance of eight NI-FECG extraction algorithms on the artificial database focusing on: FQRS detection and morphological analysis (foetal QT and T/QRS ratio). The overall median FQRS detection accuracies (i.e. considering all non-stationary events) for the best performing methods in each group were 99.9% for BSS, 97.9% for AM and 96.0% for TS. Both FQRS detections and morphological parameters were shown to heavily depend on the extraction techniques and signal-to-noise ratio. Particularly, it is shown that their evaluation in the source domain, obtained after using a BSS technique, should be

  20. Use of trimetasphere metallofullerene MRI contrast agent for the non-invasive longitudinal tracking of stem cells in the lung.

    Science.gov (United States)

    Murphy, Sean V; Hale, Austin; Reid, Tanya; Olson, John; Kidiyoor, Amritha; Tan, Josh; Zhou, Zhiguo; Jackson, John; Atala, Anthony

    2016-04-15

    Magnetic Resonance Imaging (MRI) is a commonly used, non-invasive imaging technique that provides visualization of soft tissues with high spatial resolution. In both a research and clinical setting, the major challenge has been identifying a non-invasive and safe method for longitudinal tracking of delivered cells in vivo. The labeling and tracking of contrast agent labeled cells using MRI has the potential to fulfill this need. Contrast agents are often used to enhance the image contrast between the tissue of interest and surrounding tissues with MRI. The most commonly used MRI contrast agents contain Gd(III) ions. However, Gd(III) ions are highly toxic in their ionic form, as they tend to accumulate in the liver, spleen, kidney and bones and block calcium channels. Endohedral metallofullerenes such as trimetallic nitride endohedral metallofullerenes (Trimetasphere®) are one unique class of fullerene molecules where a Gd3N cluster is encapsulated inside a C80 carbon cage referred to as Gd3N@C80. These endohedral metallofullerenes have several advantages over small chelated Gd(III) complexes such as increased stability of the Gd(III) ion, minimal toxic effects, high solubility in water and high proton relativity. In this study, we describe the evaluation of gadolinium-based Trimetasphere® positive contrast agent for the ​in vitro labeling and in vivo tracking of human amniotic fluid-derived stem cells within lung tissue. In addition, we conducted a 'proof-of-concept' experiment demonstrating that this methodology can be used to track the homing of stem cells to injured lung tissue and provide longitudinal analysis of cell localization over an extended time course. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Non-invasive measurement of brain glycogen by NMR spectroscopy and its application to the study of brain metabolism

    Science.gov (United States)

    Tesfaye, Nolawit; Seaquist, Elizabeth R.; Öz, Gülin

    2011-01-01

    Glycogen is the reservoir for glucose in the brain. Beyond the general agreement that glycogen serves as an energy source in the central nervous system, its exact role in brain energy metabolism has yet to be elucidated. Experiments performed in cell and tissue culture and animals have shown that glycogen content is affected by several factors including glucose, insulin, neurotransmitters, and neuronal activation. The study of in vivo glycogen metabolism has been hindered by the inability to measure glycogen non-invasively, but in the past several years, the development of a non-invasive localized 13C nuclear magnetic resonance (NMR) spectroscopy method has enabled the study of glycogen metabolism in the conscious human. With this technique, 13C-glucose is administered intravenously and its incorporation into and wash-out from brain glycogen is tracked. One application of this method has been to the study of brain glycogen metabolism in humans during hypoglycemia: data have shown that mobilization of brain glycogen is augmented during hypoglycemia and, after a single episode of hypoglycemia, glycogen synthesis rate is increased, suggesting that glycogen stores rebound to levels greater than baseline. Such studies suggest glycogen may serve as a potential energy reservoir in hypoglycemia and may participate in the brain's adaptation to recurrent hypoglycemia and eventual development of hypoglycemia unawareness. Beyond this focused area of study, 13C NMR spectroscopy has a broad potential for application in the study of brain glycogen metabolism and carries the promise of a better understanding of the role of brain glycogen in diabetes and other conditions. PMID:21732401

  2. Non-invasive determination of the complete elastic moduli of spider silks

    Science.gov (United States)

    Koski, Kristie J.; Akhenblit, Paul; McKiernan, Keri; Yarger, Jeffery L.

    2013-03-01

    Spider silks possess nature’s most exceptional mechanical properties, with unrivalled extensibility and high tensile strength. Unfortunately, our understanding of silks is limited because the complete elastic response has never been measured—leaving a stark lack of essential fundamental information. Using non-invasive, non-destructive Brillouin light scattering, we obtain the entire stiffness tensors (revealing negative Poisson’s ratios), refractive indices, and longitudinal and transverse sound velocities for major and minor ampullate spider silks: Argiope aurantia, Latrodectus hesperus, Nephila clavipes, Peucetia viridans. These results completely quantify the linear elastic response for all possible deformation modes, information unobtainable with traditional stress-strain tests. For completeness, we apply the principles of Brillouin imaging to spatially map the elastic stiffnesses on a spider web without deforming or disrupting the web in a non-invasive, non-contact measurement, finding variation among discrete fibres, junctions and glue spots. Finally, we provide the stiffness changes that occur with supercontraction.

  3. Validation of non-invasive haemodynamic methods in patients with liver disease

    DEFF Research Database (Denmark)

    Brittain, Jane M; Busk, Troels M; Møller, Søren

    2018-01-01

    Patients with advanced cirrhosis often present a hyperdynamic circulation characterized by a decrease in systolic and diastolic blood pressure (SBP and DBP), and an increase in heart rate (HR) and cardiac output (CO). Accurate assessment of the altered circulation can be performed invasively......; however, due to the disadvantages of this approach, non-invasive methods are warranted. The purpose of this study was to compare continuous non-invasive measurements of haemodynamic variables by the Finometer and the Task Force Monitor with simultaneous invasive measurements. In 25 patients with cirrhosis......, respectively; and CO: 0·1 ± 1·6 and -1·0 ± 2·0 L min(-1) , respectively. The study demonstrates that the overall performances of the Finometer and the Task Force Monitor in estimating absolute values of SBP, DBP, HR and CO in patients with cirrhosis are not equivalent to the gold standard, but may have...

  4. Non-invasive blood glucose monitor based on spectroscopy using a smartphone.

    Science.gov (United States)

    Dantu, Vishnu; Vempati, Jagannadh; Srivilliputhur, Srinivasan

    2014-01-01

    Development of a novel method for non-invasive measurement of blood glucose concentration using smartphone is discussed. Our research work has three major contributions to society and science. First, we modified and extended the Beer-Lambert's law in physics to accommodate for multiple wavelengths. This extension can aid researchers who wish to perform optical spectroscopy. Second, we successfully developed a creative and non-invasive way for diabetic patients to measure glucose levels via a smartphone. Researchers and chemists can now use their smartphones to determine the absorbance and, therefore, concentration of a chemical. Third, we created an inexpensive way to perform optical spectroscopy by using a smartphone. Monitoring blood glucose using a smartphone application that simply uses equipment already available on smartphones will improve the lives of diabetic patients who can continuously check their blood glucose levels while avoiding the current inconvenient, unhygienic, and costly invasive glucose meters.

  5. Early predictors of success of non-invasive positive pressure ventilation in hypercapnic respiratory failure.

    Science.gov (United States)

    Bhattacharyya, D; Prasad, Bnbm; Tampi, P S; Ramprasad, R

    2011-10-01

    Non-invasive positive pressure ventilation (NIPPV) has emerged as a significant advancement in the management of acute hypercapnic respiratory failure. Patients with hypercapnic respiratory failure requiring ventilation therapy (respiratory rate [RR] of > 30 breaths per minutes, PaCO2 > 55 mmHg and arterial pH success group and these parameters continued to improve even after four and 24 hours of NIPPV treatment. Out of 24 (24%) patients who failed to respond, 13 (54%) needed endotracheal intubation within one hour. The failure group had higher baseline HR than the success group. Improvement in HR, RR, pH, and PCO2 one hour after putting the patient on NIPPV predicts success of non-invasive positive pressure ventilation in hypercapnic respiratory failure.

  6. Case report: Non-invasive neurally adjusted ventilatory assist in a newborn with unilateral diaphragmatic paralysis.

    Science.gov (United States)

    Roosens, Sander; Derriks, Frank; Cools, Filip

    2016-11-01

    Diaphragmatic paralysis is a rare cause of respiratory distress in the newborn. In this paper, a patient with unilateral phrenic nerve injury after traumatic delivery is presented. The child inadequately responded to standard respiratory supportive measures. Non-invasive neurally adjusted ventilatory assist (NIV-NAVA®), providing an optimally synchronized respiratory support proportional to the effort of the patient, resulted in prompt clinical and biological improvement of the patient's respiratory condition. NAVA is a relatively new mode of ventilation in neonatal care. In this case of unilateral diaphragmatic paralysis, it provided an alternative strategy of non-invasive respiratory support avoiding prolonged mechanical ventilation. Pediatr Pulmonol. 2016;51:E37-E39. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  7. Non-invasive investigation of the upper gastrointestinal tract using technetium - 99m

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, T V [Royal Infirmary, Edinburgh (UK)

    1979-01-01

    The use of technetium - 99m in the non-invasive investigation of the upper gastrointestinal tract is discussed with particular reference to the evolution of a method of assessing gastric function or gastric acid secretion non-invasively and to the applications of this method in the investigation of surgical patients with disease of the upper gastrointestinal tract. The assessment of maximal acid output and the insulin response is described and the use of the test in the diagnosis of pernicious anaemia, hypo- and hyperchlorhydric states, gastric cancer, hiatus hernia and Barrett's oesophagus, coeliac disease, Meckel's diverticulum, and abdominal aortic aneurism outlined. The use of chemicals labelled with this tracer in hepatobilary scanning is briefly described.

  8. Non-invasive imaging using reporter genes altering cellular water permeability

    Science.gov (United States)

    Mukherjee, Arnab; Wu, Di; Davis, Hunter C.; Shapiro, Mikhail G.

    2016-12-01

    Non-invasive imaging of gene expression in live, optically opaque animals is important for multiple applications, including monitoring of genetic circuits and tracking of cell-based therapeutics. Magnetic resonance imaging (MRI) could enable such monitoring with high spatiotemporal resolution. However, existing MRI reporter genes based on metalloproteins or chemical exchange probes are limited by their reliance on metals or relatively low sensitivity. Here we introduce a new class of MRI reporters based on the human water channel aquaporin 1. We show that aquaporin overexpression produces contrast in diffusion-weighted MRI by increasing tissue water diffusivity without affecting viability. Low aquaporin levels or mixed populations comprising as few as 10% aquaporin-expressing cells are sufficient to produce MRI contrast. We characterize this new contrast mechanism through experiments and simulations, and demonstrate its utility in vivo by imaging gene expression in tumours. Our results establish an alternative class of sensitive, metal-free reporter genes for non-invasive imaging.

  9. Non-Invasive Brain Stimulation to Enhance Post-Stroke Recovery.

    Science.gov (United States)

    Kubis, Nathalie

    2016-01-01

    Brain plasticity after stroke remains poorly understood. Patients may improve spontaneously within the first 3 months and then more slowly in the coming year. The first day, decreased edema and reperfusion of the ischemic penumbra may possibly account for these phenomena, but the improvement during the next weeks suggests plasticity phenomena and cortical reorganization of the brain ischemic areas and of more remote areas. Indeed, the injured ischemic motor cortex has a reduced cortical excitability at the acute phase and a suspension of the topographic representation of affected muscles, whereas the contralateral motor cortex has an increased excitability and an enlarged somatomotor representation; furthermore, contralateral cortex exerts a transcallosal interhemispheric inhibition on the ischemic cortex. This results from the imbalance of the physiological reciprocal interhemispheric inhibition of each hemisphere on the other, contributing to worsening of neurological deficit. Cortical excitability is measurable through transcranial magnetic stimulation (TMS) and prognosis has been established according to the presence of motor evoked potentials (MEP) at the acute phase of stroke, which is predictive of better recovery. Conversely, the lack of response to early stimulation is associated with a poor functional outcome. Non-invasive stimulation techniques such as repetitive TMS (rTMS) or transcranial direct current stimulation (tDCS) have the potential to modulate brain cortical excitability with long lasting effects. In the setting of cerebrovascular disease, around 1000 stroke subjects have been included in placebo-controlled trials so far, most often with an objective of promoting motor recovery of the upper limb. High frequency repetitive stimulation (>3 Hz) rTMS, aiming to increase excitability of the ischemic cortex, or low frequency repetitive stimulation (≤1 Hz), aiming to reduce excitability of the contralateral homonymous cortex, or combined therapies

  10. Non-invasive measuring instrument of kVp, R/M and exposure time

    International Nuclear Information System (INIS)

    Laan, Flavio T. van der; Elbern, Alwin W.

    1996-01-01

    The development of an instrument for fast measurement of essential parameters related to quality control of X-ray equipment is described. The unit is designed with a 80 C31 micro controller, a function keyboard, an αnumeric display and a probe with PV diodes. Testing and calibration in this non-invasive instrument has been done at the X-rays equipment for the Santa Rita Hospital in Porto Alegre, Rio Grande do Sul State, Brazil

  11. Contribution of mechanical unloading to trabecular bone loss following non-invasive knee injury in mice

    OpenAIRE

    Anderson, Matthew J.; Diko, Sindi; Baehr, Leslie M.; Baar, Keith; Bodine, Sue C.; Christiansen, Blaine A.

    2016-01-01

    Development of osteoarthritis commonly involves degeneration of epiphyseal trabecular bone. In previous studies, we observed 30–44% loss of epiphyseal trabecular bone (BV/TV) from the distal femur within one week following non-invasive knee injury in mice. Mechanical unloading (disuse) may contribute to this bone loss, however it is unclear to what extent the injured limb is unloaded following injury, and whether disuse can fully account for the observed magnitude of bone loss. In this study,...

  12. Urinary high molecular weight matrix metalloproteinases as non-invasive biomarker for detection of bladder cancer

    OpenAIRE

    Mohammed, Mohammed A; Seleim, Manar F; Abdalla, Mohga S; Sharada, Hayat M; Abdel Wahab, Abdel Hady A

    2013-01-01

    Background Matrix Metalloproteinases (MMPs) are key molecules for tumor growth, invasion and metastasis. Over-expression of different MMPs in tumor tissues can disturb the homeostasis and increase the level of various body fluids. Many MMPs including high molecular weights (HMWs) were detected in the urine of prostate and bladder cancer patients. Our aim here is to assess the usefulness of HMW MMPs as non invasive biomarkers in bilharzial bladder cancer in Egyptian patients. Methods The activ...

  13. Comparing the Validity of Non-Invasive Methods in Measuring Thoracic Kyphosis and Lumbar Lordosis

    Directory of Open Access Journals (Sweden)

    Mohammad Yousefi

    2012-04-01

    Full Text Available Background: the purpose of this article is to study the validity of each of the non-invasive methods (flexible ruler, spinal mouse, and processing the image versus the one through-Ray radiation (the basic method and comparing them with each other.Materials and Methods: for evaluating the validity of each of these non-invasive methods, the thoracic Kyphosis and lumber Lordosis angle of 20 students of Birjand University (age mean and standard deviation: 26±2, weight: 72±2.5 kg, height: 169±5.5 cm through fours methods of flexible ruler, spinal mouse, and image processing and X-ray.Results: the results indicated that the validity of the methods including flexible ruler, spinal mouse, and image processing in measuring the thoracic Kyphosis and lumber Lordosis angle respectively have an adherence of 0.81, 0.87, 0.73, 0.76, 0.83, 0.89 (p>0.05. As a result, regarding the gained validity against the golden method of X-ray, it could be stated that the three mentioned non-invasive methods have adequate validity. In addition, the one-way analysis of variance test indicated that there existed a meaningful relationship between the three methods of measuring the thoracic Kyphosis and lumber Lordosis, and with respect to the Tukey’s test result, the image processing method is the most precise one.Conclusion as a result, this method could be used along with other non-invasive methods as a valid measuring method.

  14. Non-invasive method of determination of thermoelectric materials figure of merit

    Directory of Open Access Journals (Sweden)

    Ashcheulov А. А.

    2009-04-01

    Full Text Available Thermoelectric effects arising in a sample placed in a measuring oscillating loop have been studied. It has been shown that asymmetric character of flowing current results in a volumetric bundle of induced Foucault currents and regions of Peltier heat release by thermoelectric sample which leads to increasing of irreversible heat losses recorded by measuring oscillating loop. The presence of this effect has caused the emergence of ingenious non-invasive method for recording of thermoelectric materials figure of merit.

  15. Non-Invasive Imaging Method of Microwave Near Field Based on Solid State Quantum Sensing

    OpenAIRE

    Yang, Bo; Du, Guanxiang; Dong, Yue; Liu, Guoquan; Hu, Zhenzhong; Wang, Yongjin

    2018-01-01

    In this paper, we propose a non-invasive imaging method of microwave near field using a diamond containing nitrogen-vacancy centers. We applied synchronous pulsed sequence combined with charge coupled device camera to measure the amplitude of the microwave magnetic field. A full reconstruction formulation of the local field vector, including the amplitude and phase, is developed by measuring both left and right circular polarizations along the four nitrogen-vacancy axes. Compared to the raste...

  16. The use of non-invasive instruments in characterizing human facial and abdominal skin.

    Science.gov (United States)

    Bailey, Steven H; Oni, Georgette; Brown, Spencer A; Kashefi, Natalie; Cheriyan, Salim; Maxted, Michael; Stewart, Collin; Jones, Caroline; Maluso, Patrick; Kenkel, Ashley M; Kenkel, Matthew M; Hoopman, John; Barton, Fritz; Kenkel, Jeffrey M

    2012-02-01

    The skin is highly variable. This variation, although helpful for function, causes inconsistencies when assessed using subjective scales. The purpose of this study is to measure differences in skin on the face and abdomen using non-invasive, objective devices as a method to eliminate subjective error and help reduce intra- and inter-observer variability in clinical analysis. Eighty-eight subjects between the ages of 18 and 61 were enrolled in this study. These subjects varied in age, ethnicity, and Fitzpatrick score. Facial analysis was performed by clinical evaluation and utilizing non-invasive objective devices which included the DermaScan C 20 MHz HFUS (Cyberderm, Broomall, PA), Tru Vu (Johnson and Johnson), BTC 2000 (SRLI Technologies, Nashville, TN), Derma Unit SSC3 (CK Electronic, Köln, Germany), and the Chromometer. Non-invasive devices were shown to be consistent and accurate through repeated measurement at each of the anatomical points with error rates of less than 5%. Chromometer measurements were able to categorize patients into Fitzpatrick level. DermaScan measurements demonstrated decreasing skin thicknesses associated with increasing age, smoking, and female gender. Derma Unit SSC 3 showed gender and sun exposure related differences in sebum concentration, pH, and moisture content. The Derma Unit SSC 3 sebum concentration also showed correlation with Tru Vu readings for clogged pores and bacterial activity. The skin assessment scales that are in use today are often prone to variability and inaccuracy due to their subjectivity. Use of the described objective non-invasive facial analysis method provides an accurate, objective analysis of human skin which can be used to measure changes pre- and post-operatively, or even screen patients prior to procedure to identify non-responders or those prone to adverse events. Utilization of these devices introduces a foundation on which a strong evidence-based approach to aesthetic medicine can be built. Copyright

  17. The predictive value of respiratory function tests for non-invasive ventilation in amyotrophic lateral sclerosis

    OpenAIRE

    Tilanus, T. B. M.; Groothuis, J. T.; TenBroek-Pastoor, J. M. C.; Feuth, T. B.; Heijdra, Y. F.; Slenders, J. P. L.; Doorduin, J.; Van Engelen, B. G.; Kampelmacher, M. J.; Raaphorst, J.

    2017-01-01

    BACKGROUND: Non-invasive ventilation (NIV) improves survival and quality of life in amyotrophic lateral sclerosis (ALS) patients. The timing of referral to a home ventilation service (HVS), which is in part based on respiratory function tests, has shown room for improvement. It is currently unknown which respiratory function test predicts an appropriate timing of the initiation of NIV. METHODS: We analysed, retrospectively, serial data of five respiratory function tests: forced vital capacity...

  18. Composite Biomarkers For Non-invasive Screening, Diagnosis And Prognosis Of Colorectal Cancer

    KAUST Repository

    Mansour, Hicham

    2014-09-11

    The present invention concerns particular biomarkers for diagnosing and/or prognosticating colorectal cancer, in particular in a non-invasive manner. The methods and compositions concern analysis of methylation patterns of one or more genes from a set of 29 genes identified as described herein. In certain embodiments, the gene set includes at least P15.INK4b, SST, GAS7, CNRIP1, and PIK3CG.

  19. Composite Biomarkers For Non-invasive Screening, Diagnosis And Prognosis Of Colorectal Cancer

    KAUST Repository

    Mansour, Hicham; Incitti, Roberto; Bajic, Vladimir B.

    2014-01-01

    The present invention concerns particular biomarkers for diagnosing and/or prognosticating colorectal cancer, in particular in a non-invasive manner. The methods and compositions concern analysis of methylation patterns of one or more genes from a set of 29 genes identified as described herein. In certain embodiments, the gene set includes at least P15.INK4b, SST, GAS7, CNRIP1, and PIK3CG.

  20. A new non-invasive and relocatable immobilization frame for fractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Theodorou, K.; Kappas, C.; Tsokas, C.

    1998-01-01

    Purpose: A newly developed non-invasive immobilization frame for stereotactic radiotherapy is presented, which is intended to be used for both imaging (computed tomography (CT) and angiography) and radiotherapeutic procedures. Materials and methods: The frame is made of duraluminium so as to be stable and light and it has an elliptical shape. The immobilization is achieved using three stable locations on the patient's head, i.e. the upper dentition, the nose and the back of the neck. The fixation on the three locations ensures complete immobilization in all directions. Results: The immobilization frame can be fitted as many times as is needed to most heads. In order to assess the accuracy of relocation, repeated fittings on two volunteers and on 22 patients undergoing stereotactic treatment were performed (more than 200 mountings in total), which showed maximum anterior-posterior, inferior-superior and lateral reproducibility in positioning of less than 1 mm in all cases. Conclusions and discussion: The in-house-constructed stereotactic frame is simple to use, easily made, non-invasive, relocatable and well tolerated by the patients, providing the possibility of multiple fractions. The major advantage of using such a non-invasive stereotactic frame is the flexibility in timing the different diagnostic procedures (CT and angiography) as well as providing the possibility to extend the use to large brain lesions (treatment without an additional collimator) where a high precision is also required. It also offers significant labour and cost saving over the invasive frames and the majority of the non-invasive frames. To date, 22 patients with ages varying between 12 and 70 years have been treated using this method. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  1. A meta-analysis of trait differences between invasive and non-invasive plant species

    OpenAIRE

    van Kleunen, Mark; Weber, Ewald; Fischer, Markus

    2010-01-01

    A major aim in ecology is identifying determinants of invasiveness. We performed a meta-analysis of 117 field or experimental-garden studies that measured pair-wise trait differences of a total of 125 invasive and 196 non-invasive plant species in the invasive range of the invasive species. We tested whether invasiveness is associated with performance-related traits (physiology, leaf-area allocation, shoot allocation, growth rate, size and fitness), and whether such associations depend on typ...

  2. Non-invasive multi wavelengths sensorsystem for measuring carboxy-and methemoglobin

    Directory of Open Access Journals (Sweden)

    Gewiß Helge

    2017-09-01

    Full Text Available Standard pulse oximetry only measures the functional derivatives oxyhemoglobin (O2Hb and deoxyhemoglobin (HHb to calculate the arterial oxygenation. However, the two dysfunctional hemoglobin derivatives carboxyhemoglobin (COHb and methemoglobin (MetHb are of much interest. The gold standard detecting abnormal concentration of COHb or MetHb is the blood gas analysis (BGA. In this paper a non-invasive method for measuring these derivatives and a setup for validation is presented.

  3. Non-Invasive Radiofrequency Field Treatment to Produce Hepatic Hyperthermia: Efficacy and Safety in Swine

    OpenAIRE

    ,; ,; ,; ,; ,; ,; ,; ,; ,

    2017-01-01

    The Kanzius non-invasive radio-frequency hyperthermia system (KNiRFH) has been investigated as a treatment option for hepatic hyperthermia cancer therapy. The treatment involves exposing the patient to an external high-power RF (13.56 MHz) electric field, whereby the propagating waves penetrate deep into the tumor causing targeted heating based on differential tissue dielectric properties. However, a comprehensive examination of the Kanzius system alongside any associated toxicities and its a...

  4. Non-invasive monitoring of Streptococcus pyogenes vaccine efficacy using biophotonic imaging.

    Directory of Open Access Journals (Sweden)

    Faraz M Alam

    Full Text Available Streptococcus pyogenes infection of the nasopharynx represents a key step in the pathogenic cycle of this organism and a major focus for vaccine development, requiring robust models to facilitate the screening of potentially protective antigens. One antigen that may be an important target for vaccination is the chemokine protease, SpyCEP, which is cell surface-associated and plays a role in pathogenesis. Biophotonic imaging (BPI can non-invasively characterize the spatial location and abundance of bioluminescent bacteria in vivo. We have developed a bioluminescent derivative of a pharyngeal S. pyogenes strain by transformation of an emm75 clinical isolate with the luxABCDE operon. Evaluation of isogenic recombinant strains in vitro and in vivo confirmed that bioluminescence conferred a growth deficit that manifests as a fitness cost during infection. Notwithstanding this, bioluminescence expression permitted non-invasive longitudinal quantitation of S. pyogenes within the murine nasopharynx albeit with a detection limit corresponding to approximately 10(5 bacterial colony forming units (CFU in this region. Vaccination of mice with heat killed streptococci, or with SpyCEP led to a specific IgG response in the serum. BPI demonstrated that both vaccine candidates reduced S. pyogenes bioluminescence emission over the course of nasopharyngeal infection. The work suggests the potential for BPI to be used in the non-invasive longitudinal evaluation of potential S. pyogenes vaccines.

  5. Radiological protection requirements applicable to non-invasive inspection of charges with ionizing radiation

    International Nuclear Information System (INIS)

    Crespo, S.C.; Palmieri, J.A.S.; Silva, F.C.A. da

    2017-01-01

    The US twin towers attack in 2001 raised concerns about terrorism, illicit trafficking of materials and the possible use of a 'dirty bomb' (DDR), affecting the control of entry and exit of products. Thus, the use of ionizing radiation scanning systems of containers at ports and borders was started to investigate possible entries of illegal material. Brazil, adhering to this concern and due to the holding of major events such as RIO + 20, World Cup, Olympics, etc., increased safety in the movement of goods using non-invasive inspection. Linear electron accelerators, which produce high energy X-rays in the range of 1.5 to 9 MeV, are used to inspect the containers. Since in Brazil there is no specific technical regulation for the operation of non-invasive inspection equipment with X-rays and linear accelerators, ten main technical requirements are presented. It is essential that a technical regulation is drawn up by placing the system of non-invasive inspection of cargo with ionizing radiation in the international radiation protection standard

  6. Non-invasive prediction of hematocrit levels by portable visible and near-infrared spectrophotometer.

    Science.gov (United States)

    Sakudo, Akikazu; Kato, Yukiko Hakariya; Kuratsune, Hirohiko; Ikuta, Kazuyoshi

    2009-10-01

    After blood donation, in some individuals having polycythemia, dehydration causes anemia. Although the hematocrit (Ht) level is closely related to anemia, the current method of measuring Ht is performed after blood drawing. Furthermore, the monitoring of Ht levels contributes to a healthy life. Therefore, a non-invasive test for Ht is warranted for the safe donation of blood and good quality of life. A non-invasive procedure for the prediction of hematocrit levels was developed on the basis of a chemometric analysis of visible and near-infrared (Vis-NIR) spectra of the thumbs using portable spectrophotometer. Transmittance spectra in the 600- to 1100-nm region from thumbs of Japanese volunteers were subjected to a partial least squares regression (PLSR) analysis and leave-out cross-validation to develop chemometric models for predicting Ht levels. Ht levels of masked samples predicted by this model from Vis-NIR spectra provided a coefficient of determination in prediction of 0.6349 with a standard error of prediction of 3.704% and a detection limit in prediction of 17.14%, indicating that the model is applicable for normal and abnormal value in Ht level. These results suggest portable Vis-NIR spectrophotometer to have potential for the non-invasive measurement of Ht levels with a combination of PLSR analysis.

  7. Non-invasive prenatal detection of achondroplasia using circulating fetal DNA in maternal plasma.

    Science.gov (United States)

    Lim, Ji Hyae; Kim, Mee Jin; Kim, Shin Young; Kim, Hye Ok; Song, Mee Jin; Kim, Min Hyoung; Park, So Yeon; Yang, Jae Hyug; Ryu, Hyun Mee

    2011-02-01

    To perform a reliable non-invasive detection of the fetal achondroplasia using maternal plasma. We developed a quantitative fluorescent-polymerase chain reaction (QF-PCR) method suitable for detection of the FGFR3 mutation (G1138A) causing achondroplasia. This method was applied in a non-invasive detection of the fetal achondroplasia using circulating fetal-DNA (cf-DNA) in maternal plasma. Maternal plasmas were obtained at 27 weeks of gestational age from women carrying an achondroplasia fetus or a normal fetus. Two percent or less achondroplasia DNA was reliably detected by QF-PCR. In a woman carrying a normal fetus, analysis of cf-DNA showed only one peak of the wild-type G allele. In a woman expected an achondroplasia fetus, analysis of cf-DNA showed the two peaks of wild-type G allele and mutant-type A allele and accurately detected the fetal achondroplasia. The non-invasive method using maternal plasma and QF-PCR may be useful for diagnosis of the fetal achondroplasia.

  8. Optimized intravenous flat detector CT for non-invasive visualization of intracranial stents: first results

    International Nuclear Information System (INIS)

    Struffert, Tobias; Kloska, Stephan; Engelhorn, Tobias; Ott, Sabine; Doelken, Marc; Saake, Marc; Doerfler, Arnd; Deuerling-Zheng, Yu.; Koehrmann, Martin

    2011-01-01

    As stents for treating intracranial atherosclerotic stenosis may develop in-stent re-stenosis (ISR) in up to 30%, follow-up imaging is mandatory. Residual stenosis (RS) is not rare. We evaluated an optimised Flat Detector CT protocol with intravenous contrast material application (i.v. FD-CTA) for non-invasive follow-up. In 12 patients with intracranial stents, follow-up imaging was performed using i.v. FD-CTA. MPR, subtracted MIP and VRT reconstructions were used to correlate to intra-arterial angiography (DSA). Two neuroradiologists evaluated the images in anonymous consensus reading and calculated the ISR or RS. Correlation coefficients and a Wilcoxon test were used for statistical analysis. In 4 patients, no stenosis was detected. In 6 patients RS and in two cases ISR by intima hyperplasia perfectly visible on MPR reconstructions of i.v. FD-CTA were detected. Wilcoxon's test showed no significant differences between the methods (p > 0.05). We found a high correlation with coefficients of the pairs DSA/ FD-CT MIP r = 0.91, DSA/ FD-CT MPR r = 0.82 and FD-CT MIP/ FD-CT MPR r = 0.8. Intravenous FD-CTA could clearly visualise the stent and the lumen, allowing ISR or RS to be recognised. FD-CTA provides a non-invasive depiction of intracranial stents and might replace DSA for non-invasive follow-up imaging. (orig.)

  9. Equine behavioral enrichment toys as tools for non-invasive recovery of viral and host DNA.

    Science.gov (United States)

    Seeber, Peter A; Soilemetzidou, Sanatana E; East, Marion L; Walzer, Chris; Greenwood, Alex D

    2017-09-01

    Direct collection of samples from wildlife can be difficult and sometimes impossible. Non-invasive remote sampling for the purpose of DNA extraction is a potential tool for monitoring the presence of wildlife at the individual level, and for identifying the pathogens shed by wildlife. Equine herpesviruses (EHV) are common pathogens of equids that can be fatal if transmitted to other mammals. Transmission usually occurs by nasal aerosol discharge from virus-shedding individuals. The aim of this study was to validate a simple, non-invasive method to track EHV shedding in zebras and to establish an efficient protocol for genotyping individual zebras from environmental DNA (eDNA). A commercially available horse enrichment toy was deployed in captive Grévy's, mountain, and plains zebra enclosures and swabbed after 4-24 hr. Using eDNA extracted from these swabs four EHV strains (EHV-1, EHV-7, wild ass herpesvirus and zebra herpesvirus) were detected by PCR and confirmed by sequencing, and 12 of 16 zebras present in the enclosures were identified as having interacted with the enrichment toy by mitochondrial DNA amplification and sequencing. We conclude that, when direct sampling is difficult or prohibited, non-invasive sampling of eDNA can be a useful tool to determine the genetics of individuals or populations and for detecting pathogen shedding in captive wildlife. © 2017 Wiley Periodicals, Inc.

  10. Non-invasive Markers of Liver Fibrosis: Adjuncts or Alternatives to Liver Biopsy?

    Science.gov (United States)

    Chin, Jun L.; Pavlides, Michael; Moolla, Ahmad; Ryan, John D.

    2016-01-01

    Liver fibrosis reflects sustained liver injury often from multiple, simultaneous factors. Whilst the presence of mild fibrosis on biopsy can be a reassuring finding, the identification of advanced fibrosis is critical to the management of patients with chronic liver disease. This necessity has lead to a reliance on liver biopsy which itself is an imperfect test and poorly accepted by patients. The development of robust tools to non-invasively assess liver fibrosis has dramatically enhanced clinical decision making in patients with chronic liver disease, allowing a rapid and informed judgment of disease stage and prognosis. Should a liver biopsy be required, the appropriateness is clearer and the diagnostic yield is greater with the use of these adjuncts. While a number of non-invasive liver fibrosis markers are now used in routine practice, a steady stream of innovative approaches exists. With improvement in the reliability, reproducibility and feasibility of these markers, their potential role in disease management is increasing. Moreover, their adoption into clinical trials as outcome measures reflects their validity and dynamic nature. This review will summarize and appraise the current and novel non-invasive markers of liver fibrosis, both blood and imaging based, and look at their prospective application in everyday clinical care. PMID:27378924

  11. A new CFD based non-invasive method for functional diagnosis of coronary stenosis.

    Science.gov (United States)

    Xie, Xinzhou; Zheng, Minwen; Wen, Didi; Li, Yabing; Xie, Songyun

    2018-03-22

    Accurate functional diagnosis of coronary stenosis is vital for decision making in coronary revascularization. With recent advances in computational fluid dynamics (CFD), fractional flow reserve (FFR) can be derived non-invasively from coronary computed tomography angiography images (FFR CT ) for functional measurement of stenosis. However, the accuracy of FFR CT is limited due to the approximate modeling approach of maximal hyperemia conditions. To overcome this problem, a new CFD based non-invasive method is proposed. Instead of modeling maximal hyperemia condition, a series of boundary conditions are specified and those simulated results are combined to provide a pressure-flow curve for a stenosis. Then, functional diagnosis of stenosis is assessed based on parameters derived from the obtained pressure-flow curve. The proposed method is applied to both idealized and patient-specific models, and validated with invasive FFR in six patients. Results show that additional hemodynamic information about the flow resistances of a stenosis is provided, which cannot be directly obtained from anatomy information. Parameters derived from the simulated pressure-flow curve show a linear and significant correlations with invasive FFR (r > 0.95, P < 0.05). The proposed method can assess flow resistances by the pressure-flow curve derived parameters without modeling of maximal hyperemia condition, which is a new promising approach for non-invasive functional assessment of coronary stenosis.

  12. Non-invasive detection of urothelial cancer through the analysis of driver gene mutations and aneuploidy

    Science.gov (United States)

    Li, Lu; Douville, Christopher; Wang, Yuxuan; Cohen, Joshua David; Taheri, Diana; Silliman, Natalie; Schaefer, Joy; Ptak, Janine; Dobbyn, Lisa; Papoli, Maria; Kinde, Isaac; Afsari, Bahman; Tregnago, Aline C; Bezerra, Stephania M; VandenBussche, Christopher; Fujita, Kazutoshi; Ertoy, Dilek; Cunha, Isabela W; Yu, Lijia; Bivalacqua, Trinity J; Grollman, Arthur P; Diaz, Luis A; Karchin, Rachel; Danilova, Ludmila; Huang, Chao-Yuan; Shun, Chia-Tung; Turesky, Robert J; Yun, Byeong Hwa; Rosenquist, Thomas A; Pu, Yeong-Shiau; Hruban, Ralph H; Tomasetti, Cristian; Papadopoulos, Nickolas; Kinzler, Ken W

    2018-01-01

    Current non-invasive approaches for detection of urothelial cancers are suboptimal. We developed a test to detect urothelial neoplasms using DNA recovered from cells shed into urine. UroSEEK incorporates massive parallel sequencing assays for mutations in 11 genes and copy number changes on 39 chromosome arms. In 570 patients at risk for bladder cancer (BC), UroSEEK was positive in 83% of those who developed BC. Combined with cytology, UroSEEK detected 95% of patients who developed BC. Of 56 patients with upper tract urothelial cancer, 75% tested positive by UroSEEK, including 79% of those with non-invasive tumors. UroSEEK detected genetic abnormalities in 68% of urines obtained from BC patients under surveillance who demonstrated clinical evidence of recurrence. The advantages of UroSEEK over cytology were evident in low-grade BCs; UroSEEK detected 67% of cases whereas cytology detected none. These results establish the foundation for a new non-invasive approach for detection of urothelial cancer. PMID:29557778

  13. Recording human cortical population spikes non-invasively--An EEG tutorial.

    Science.gov (United States)

    Waterstraat, Gunnar; Fedele, Tommaso; Burghoff, Martin; Scheer, Hans-Jürgen; Curio, Gabriel

    2015-07-30

    Non-invasively recorded somatosensory high-frequency oscillations (sHFOs) evoked by electric nerve stimulation are markers of human cortical population spikes. Previously, their analysis was based on massive averaging of EEG responses. Advanced neurotechnology and optimized off-line analysis can enhance the signal-to-noise ratio of sHFOs, eventually enabling single-trial analysis. The rationale for developing dedicated low-noise EEG technology for sHFOs is unfolded. Detailed recording procedures and tailored analysis principles are explained step-by-step. Source codes in Matlab and Python are provided as supplementary material online. Combining synergistic hardware and analysis improvements, evoked sHFOs at around 600 Hz ('σ-bursts') can be studied in single-trials. Additionally, optimized spatial filters increase the signal-to-noise ratio of components at about 1 kHz ('κ-bursts') enabling their detection in non-invasive surface EEG. sHFOs offer a unique possibility to record evoked human cortical population spikes non-invasively. The experimental approaches and algorithms presented here enable also non-specialized EEG laboratories to combine measurements of conventional low-frequency EEG with the analysis of concomitant cortical population spike responses. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. The value of non-invasive techniques for the assessment of critical limb ischaemia

    NARCIS (Netherlands)

    Ubbink, D. T.; Tulevski, I. I.; den Hartog, D.; Koelemay, M. J.; Legemate, D. A.; Jacobs, M. J.

    1997-01-01

    OBJECTIVE: The European Consensus Document (ECD) defines critical ischaemia (CI) according to clinical (Fontaine) and blood pressure parameters. However, clinical symptoms may be non-specific and CI may exist without severely reduced blood pressures. This study prospectively investigated the

  15. Raman spectroscopy, a non-invasive mesurement technique for the detection of counterfeit medicines

    OpenAIRE

    Marta, Teresa Rita Pitorra

    2016-01-01

    Tese de mestrado, Engenharia Farmacêutica, Universidade de Lisboa, Faculdade de Farmácia, 2016 Perhaps no greater challenge exists for public health, patient safety, and shared global health security, than fake, falsified, fraudulent or poor quality unregulated medicines - also commonly known as “counterfeit medicines” - now endemic in the global drug supply chain (Tim K Mackey & Liang, 2013). Counterfeit medicines pose a serious risk to public health around the world. It is low- and mi...

  16. Comparison of invasive and non-invasive electromagnetic methods in soil water content estimation of a dike model

    International Nuclear Information System (INIS)

    Preko, Kwasi; Scheuermann, Alexander; Wilhelm, Helmut

    2009-01-01

    Water infiltration through a dike model under controlled flooding and drainage conditions was investigated using the gravimetric soil water sampling technique and electromagnetic techniques, in particular ground penetrating radar (GPR) applied in different forms, time domain reflectometry with intelligent microelements (TRIME-TDR) and spatial-time domain reflectometry (S-TDR). The experiments were conducted on the model in two phases. In the first phase, the model was flooded with varying water levels between 0 and 1.25 m above the waterproof base of the model. In the second phase, the characteristics of the temporal water content changes were investigated over a period of 65 days as the flood water drained off from the 1.25 m level. The dike model was constructed with soil of the texture class loamy sand. The aim of the experiment was to investigate whether GPR-based invasive and non-invasive methods were able to quantitatively observe and correctly monitor temporal changes in the volumetric water content (VWC) within embankment dams. The VWC values from the various techniques corresponded very well, especially with low VWC values. A comparison with the VWC of gravimetric soil water sampling showed a satisfactory reproducibility. Characteristic discrepancies were recorded with higher values of the VWC. Under saturated conditions only the invasive methods were able to produce reasonable values of the VWC. After the release of the highest flood level, the drainage phase could be characterized by two invasive methods based on the TDR and GPR techniques

  17. (19)F-heptuloses as tools for the non-invasive imaging of GLUT2-expressing cells

    DEFF Research Database (Denmark)

    Malaisse, Willy J; Zhang, Ying; Louchami, Karim

    2012-01-01

    Suitable analogs of d-mannoheptulose are currently considered as possible tools for the non-invasive imaging of pancreatic islet insulin-producing cells. Here, we examined whether (19)F-heptuloses could be used for non-invasive imaging of GLUT2-expressing cells. After 20 min incubation, the uptake......-mannoheptulose in inhibiting insulin release. The 1-deoxy-1-fluoro-d-mannoheptulose and 3-deoxy-3-fluoro-d-mannoheptulose only marginally affected INS-1 cell viability. These findings are compatible with the view that selected (19)F-heptuloses may represent suitable tools for the non-invasive imaging of hepatocytes...

  18. NON-INVASIVE DIAGNOSTICS OF NON-TUMOR DISORDERS WITH OPTICAL COHERENCE TOMOGRAPHY

    Directory of Open Access Journals (Sweden)

    A. E. Meller

    2016-01-01

    tubes with features typical for healthy and inflammatory states. Presence of heterogeneity in the structure of an OCT image indicated heterogeneity in the muscle layer of the fallopian tube, which allowed for a conclusion on chronic salpingitis. With OCT hysteroscopy we demonstrated the ability of OCT to visualize pathomorphologic features of chronic endometritis. The diagnostic data obtained by OCT-rhinoscopy allowed to draw preliminary conclusions on the OCT ability to detect specific features of various types of chronic rhinitis. Numerical processing of diagnostic OCT images resulted in their higher objectivity and an improvement of diagnostic accuracy of the technique. Conclusion: OCT is able to detect morphological changes induced by a  chronic inflammatory process. OCT criteria were shown to be universal for various organs. We demonstrated the possibility of non-invasive diagnostics of pathomorphologic forms of disease, showed some challenges in the development of OCT for diagnostics of non-tumor disorders and ways to overcome them are proposed, in particular, the use of image numerical processing. Further studies seem to be justified.

  19. Validity of hydration non-invasive indices during the weightcutting and official weigh-in for Olympic combat sports.

    Science.gov (United States)

    Fernández-Elías, Valentín E; Martínez-Abellán, Alberto; López-Gullón, José María; Morán-Navarro, Ricardo; Pallarés, Jesús G; De la Cruz-Sánchez, Ernesto; Mora-Rodriguez, Ricardo

    2014-01-01

    In Olympic combat sports, weight cutting is a common practice aimed to take advantage of competing in weight divisions below the athlete's normal weight. Fluid and food restriction in combination with dehydration (sauna and/or exercise induced profuse sweating) are common weight cut methods. However, the resultant hypohydration could adversely affect health and performance outcomes. The aim of this study is to determine which of the routinely used non-invasive measures of dehydration best track urine osmolality, the gold standard non-invasive test. Immediately prior to the official weigh-in of three National Championships, the hydration status of 345 athletes of Olympic combat sports (i.e., taekwondo, boxing and wrestling) was determined using five separate techniques: i) urine osmolality (UOSM), ii) urine specific gravity (USG), iii) urine color (UCOL), iv) bioelectrical impedance analysis (BIA), and v) thirst perception scale (TPS). All techniques were correlated with UOSM divided into three groups: euhydrated (G1; UOSM 250-700 mOsm · kg H2O(-1)), dehydrated (G2; UOSM 701-1080 mOsm · kg H2O(-1)), and severely dehydrated (G3; UOSM 1081-1500 mOsm · kg H2O(-1)). We found a positive high correlation between the UOSM and USG (r = 0.89: p = 0.000), although this relationship lost strength as dehydration increased (G1 r = 0.92; G2 r = 0.73; and G3 r = 0.65; p = 0.000). UCOL showed a moderate although significant correlation when considering the whole sample (r = 0.743: p = 0.000) and G1 (r = 0.702: p = 0.000) but low correlation for the two dehydrated groups (r = 0.498-0.398). TPS and BIA showed very low correlation sizes for all groups assessed. In a wide range of pre-competitive hydration status (UOSM 250-1500 mOsm · kg H2O(-1)), USG is highly associated with UOSM while being a more affordable and easy to use technique. UCOL is a suitable tool when USG is not available. However, BIA or TPS are not sensitive enough to detect hypohydration at official weight

  20. Non Invasive 3D Characterization of Materials at Multi scale Resolution in Correlative and 4D microscopy

    International Nuclear Information System (INIS)

    Lau, S.H.

    2011-01-01

    We describe a suite of novel lab-based X-ray computed tomography (CT) systems for high contrast 3D characterization of hard to soft materials with resolution across length scales. The system has similar resolution and contrast range obtained from x-ray micro and nano tomography systems in synchrotron radiation facilities, except it makes use of conventional lab sources. Samples with dimensions from several cm to several microns may be imaged non invasively at varying resolution from tens of microns to 20 nm voxel. The novel multi scale CT helps bridge the resolution, scaling and 3D visualization gap in the traditional destructive 2D imaging modalities such as optical microscopes, AFM, SEM, SEM-FIB and TEM. It provides a direct non-invasive volumetric imaging technique at the macro to nano scale, making it ideal for accurate prediction and modeling of whole systems and components. For example, using 3D visualization, segmentation and computational analysis tools, pore networks, FEA, fluid, thermal and ionic transport in various systems and materials from ceramics, geo materials, composites, metals, and coatings may be characterized and modeled. The high resolution and unique phase contrast features of the novel CTs also lend themselves very well to characterize inherently low contrast soft materials such as polymers; membranes and biological tissue or to differentiate small differences in material and mineral phases in geo material and composites. Tomography of samples may be acquired at different volume vs resolution using local tomography technique, often without sample destruction. In the emerging field of 3D correlative microscopy, these larger CT volumetric data sets can be correlated at the different length scales with conventional 2D imaging modalities. For example, after a CT scan, specimen may undergo destructive sample sectioning at specific region of interest, to obtain the corresponding 2D slices with SEM and TEM or with X-ray microanalysis derive its

  1. Non-invasive in situ identification and band assignments of diazepam, flunitrazepam and methadone hydrochloride with FT-near-infrared spectroscopy.

    Science.gov (United States)

    Ali, Hassan Refat H

    2011-03-20

    Near-infrared spectroscopy (NIR) has evolved into an important rapid, direct and non-invasive technique in drugs analysis. In this study, the suitability of NIR spectroscopy to identify two benzodiazepine derivatives, diazepam and flunitrazepam, and a synthetic opiate, methadone hydrochloride, inside USP vials and probe the solid-state form of diazepam presents in tablets has been explored. The results show the potential of NIR spectroscopy for rapid, in situ and non-destructive identification of drugs. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  2. A non invasive method to detect stratigraphy, thicknesses and pigment concentration of pictorial multilayers based on EDXRF and vis-RS: in situ applications

    International Nuclear Information System (INIS)

    Bonizzoni, L.; Caglio, S.; Galli, A.; Poldi, G.

    2008-01-01

    Energy dispersive XRF analysis (EDXRF) in association with visible reflectance spectroscopy (vis-RS), both achieved by portable instruments, can be successfully applied, in a wide range of cases, to investigate wood or canvas paintings in order to obtain some stratigraphic information with non-invasive techniques. The specific aim of this work is to use them as quantitative tools: EDXRF to reconstruct the thicknesses of the detected layers, vis-RS to report pigment concentration in the uppermost layer. We present here some in situ analyses of famous paintings by Andrea Mantegna and Giovanni Bellini, compared with stratigraphic optical microscopy observations on cross sections. Advantages and limits are pointed out. (orig.)

  3. A systematic approach for the accurate non-invasive estimation of blood glucose utilizing a novel light-tissue interaction adaptive modelling scheme

    Energy Technology Data Exchange (ETDEWEB)

    Rybynok, V O; Kyriacou, P A [City University, London (United Kingdom)

    2007-10-15

    Diabetes is one of the biggest health challenges of the 21st century. The obesity epidemic, sedentary lifestyles and an ageing population mean prevalence of the condition is currently doubling every generation. Diabetes is associated with serious chronic ill health, disability and premature mortality. Long-term complications including heart disease, stroke, blindness, kidney disease and amputations, make the greatest contribution to the costs of diabetes care. Many of these long-term effects could be avoided with earlier, more effective monitoring and treatment. Currently, blood glucose can only be monitored through the use of invasive techniques. To date there is no widely accepted and readily available non-invasive monitoring technique to measure blood glucose despite the many attempts. This paper challenges one of the most difficult non-invasive monitoring techniques, that of blood glucose, and proposes a new novel approach that will enable the accurate, and calibration free estimation of glucose concentration in blood. This approach is based on spectroscopic techniques and a new adaptive modelling scheme. The theoretical implementation and the effectiveness of the adaptive modelling scheme for this application has been described and a detailed mathematical evaluation has been employed to prove that such a scheme has the capability of extracting accurately the concentration of glucose from a complex biological media.

  4. A systematic approach for the accurate non-invasive estimation of blood glucose utilizing a novel light-tissue interaction adaptive modelling scheme

    Science.gov (United States)

    Rybynok, V. O.; Kyriacou, P. A.

    2007-10-01

    Diabetes is one of the biggest health challenges of the 21st century. The obesity epidemic, sedentary lifestyles and an ageing population mean prevalence of the condition is currently doubling every generation. Diabetes is associated with serious chronic ill health, disability and premature mortality. Long-term complications including heart disease, stroke, blindness, kidney disease and amputations, make the greatest contribution to the costs of diabetes care. Many of these long-term effects could be avoided with earlier, more effective monitoring and treatment. Currently, blood glucose can only be monitored through the use of invasive techniques. To date there is no widely accepted and readily available non-invasive monitoring technique to measure blood glucose despite the many attempts. This paper challenges one of the most difficult non-invasive monitoring techniques, that of blood glucose, and proposes a new novel approach that will enable the accurate, and calibration free estimation of glucose concentration in blood. This approach is based on spectroscopic techniques and a new adaptive modelling scheme. The theoretical implementation and the effectiveness of the adaptive modelling scheme for this application has been described and a detailed mathematical evaluation has been employed to prove that such a scheme has the capability of extracting accurately the concentration of glucose from a complex biological media.

  5. A systematic approach for the accurate non-invasive estimation of blood glucose utilizing a novel light-tissue interaction adaptive modelling scheme

    International Nuclear Information System (INIS)

    Rybynok, V O; Kyriacou, P A

    2007-01-01

    Diabetes is one of the biggest health challenges of the 21st century. The obesity epidemic, sedentary lifestyles and an ageing population mean prevalence of the condition is currently doubling every generation. Diabetes is associated with serious chronic ill health, disability and premature mortality. Long-term complications including heart disease, stroke, blindness, kidney disease and amputations, make the greatest contribution to the costs of diabetes care. Many of these long-term effects could be avoided with earlier, more effective monitoring and treatment. Currently, blood glucose can only be monitored through the use of invasive techniques. To date there is no widely accepted and readily available non-invasive monitoring technique to measure blood glucose despite the many attempts. This paper challenges one of the most difficult non-invasive monitoring techniques, that of blood glucose, and proposes a new novel approach that will enable the accurate, and calibration free estimation of glucose concentration in blood. This approach is based on spectroscopic techniques and a new adaptive modelling scheme. The theoretical implementation and the effectiveness of the adaptive modelling scheme for this application has been described and a detailed mathematical evaluation has been employed to prove that such a scheme has the capability of extracting accurately the concentration of glucose from a complex biological media

  6. Proposed Application of Fast Fourier Transform in Near Infra Red Based Non Invasive Blood Glucose Monitoring System

    Science.gov (United States)

    Jenie, R. P.; Iskandar, J.; Kurniawan, A.; Rustami, E.; Syafutra, H.; Nurdin, N. M.; Handoyo, T.; Prabowo, J.; Febryarto, R.; Rahayu, M. S. K.; Damayanthi, E.; Rimbawan; Sukandar, D.; Suryana, Y.; Irzaman; Alatas, H.

    2017-03-01

    Worldwide emergence of glycaemic status related health disorders, such as diabetes and metabolic syndrome, is growing in alarming rate. The objective was to propose new methods for non invasive blood glucose level measurement system, based on implementation of Fast Fourier Transform methods. This was an initial-lab-scale-research. Data on non invasive blood glucose measurement are referred from Scopus, Medline, and Google Scholar, from 2011 until 2016, and was used as design references, combined with in house verification. System was developed in modular fashion, based on aforementioned compiled references. Several preliminary tests to understand relationship between LED and photo-diode responses have been done. Several references were used as non invasive blood glucose measurement tools design basis. Solution is developed in modular fashion. we have proven different sensor responses to water and glucose. Human test for non invasive blood glucose level measurement system is needed.

  7. Calibration voltage test of non invasive meter for radiodiagnostic on equipment of constant potential X-ray

    International Nuclear Information System (INIS)

    Ramos, Manoel M.O.; Peixoto, J. Guilherme P.; Pereira, Marco A.G.S.

    2009-01-01

    This work evaluates the utilization of the non invasive voltage meter PTW Diavolt Universal in industrial X ray equipment of constant potential. With the performed measurements, the conclusion is that conclusion is possible, once his use limits are identified

  8. Non-invasive plant growth measurements for detection of blue-light dose response of stem elongation in Chrysanthemum morifolium

    DEFF Research Database (Denmark)

    Kjær, Katrine Heinsvig

    2012-01-01

    . In the present study a non-invasive plant growth sensor (PlantEye, Phenospex B.V, Heerlen, NL) was tested in analysing changes in diurnal stem elongation patterns and plant height in response to the spectral quality of the light environment. Plants were grown in four different LED supplemental lighting...... treatments with 0%, 12.5%, 18.5% and 22.5% blue light under greenhouse conditions in winter (18 h day/4 h night). The non-invasive measurements were carried out automatically every four hour with three repetitions, and supported by manual measurements of plant height every third day. A strong linear relation...... between the non-invasive measurements and manual measurements of plant height was achieved, and a blue-light dose-response showing a decrease in plant height in relation to an increase in blue light was demonstrated. However, the non-invasive plant growth sensor was not able to distinguish between diurnal...

  9. Frontal Eye Field, Where Art Thou? Anatomy, function and non-invasive manipulation of frontal regions involved in eye movements and associated cognitive operations

    Directory of Open Access Journals (Sweden)

    Marine eVernet

    2014-08-01

    Full Text Available The planning, control and execution of eye movements in 3D space relies on a distributed system of cortical and subcortical brain regions. Within this network, the Eye Fields have been described in animals as cortical regions in which electrical stimulation is able to trigger eye movements and influence their latency or accuracy. This review will focus on the Frontal Eye Field (FEF a hub region located in Humans in the vicinity of the pre-central sulcus and the dorsal-most portion of the superior frontal sulcus. The straightforward localization of the FEF through electrical stimulation in animals is difficult to translate to the healthy human brain, particularly with non-invasive neuroimaging techniques. Hence, in the first part of this review, we will describe attempts made to characterize the anatomical localization of this area in the human brain. The outcome of functional Magnetic Resonance Imaging (fMRI, Magneto-encephalography (MEG and particularly, non-invasive mapping methods such a Transcranial Magnetic Stimulation (TMS will be described and the variability of FEF localization across individuals and mapping techniques will be discussed. In the second part of this review, we will address the role of the FEF. We will explore its involvement both in the physiology of fixation, saccade, pursuit and vergence movements and in associated cognitive processes such as attentional orienting, visual awareness and perceptual modulation. Finally in the third part, we will review recent evidence suggesting the high level of malleability and plasticity of these regions and associated networks to non-invasive stimulation. The exploratory, diagnostic and therapeutic interest of such interventions for the modulation and improvement of perception in 3D space will be discussed.

  10. Non-invasive determination of metabolite concentrations in human transplanted kidney in vivo by 31P MR spectroscopy

    International Nuclear Information System (INIS)

    Kugel, H.; Wittsack, H.J.; Wenzel, F.; Heindel, W.; Lackner, K.; Stippel, D.

    2000-01-01

    To investigate concentrations of phosphorus-containing metabolites in human transplanted kidney in vivo by quantitative 31 P MR spectroscopy (MRS) using surface coils and to compare the obtained values with previous data. Material and Methods: In 5 patients with well-functioning transplanted kidneys, 31 P spectra were obtained with the three-dimensional localization image-selected in vivo spectroscopy technique applying a protocol for quantitative spectroscopy using surface coils. Relaxation corrected signal intensities determined by time domain fitting were used to derive absolute molar concentrations for phosphate-containing metabolites. Results: Little or no phosphocreatine in all spectra verified the absence of muscle contamination, confirming proper volume localization. The mean concentrations in the transplanted kidneys were as follows: ATP 1.60±0.26 mmol/l, PDE 2.14±0.91 mmol/l, Pi 0.66±0.25 mmol/l, PME 2.32±0.50 mmol/l. These values are consistent with previously reported values determined by other techniques. Conclusion: The non-invasive determination of absolute metabolite concentrations in human kidney using MRS supplements the use of signal intensity ratios to detect pathologic changes in the energy metabolism of transplanted kidneys

  11. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Pugliese, Francesca; Krestin, Gabriel P. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Mollet, Nico R.A.; deFeyter, Pim J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Runza, Giuseppe [University of Palermo, Department of Radiology, Palermo (Italy); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy); Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Malagutti, Patrizia [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); University of Ferrara, Department of Cardiology, Ferrara (Italy); Cademartiri, Filippo [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy)

    2006-03-15

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as {>=} 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  12. Diagnosis of non-exudative (DRY) age related macular degeneration by non-invasive photon-correlation spectroscopy.

    Science.gov (United States)

    Fankhauser, Franz Ii; Ott, Maria; Munteanu, Mihnea

    2016-01-01

    Photon-correlation spectroscopy (PCS) (quasi-elastic light scattering spectroscopy, dynamic light scattering spectroscopy) allows the non-invasively reveal of local dynamics and local heterogeneities of macromolecular systems. The capability of this technique to diagnose the retinal pathologies by in-vivo investigations of spatial anomalies of retinas displaying non-exudative senile macular degeneration was evaluated. Further, the potential use of the technique for the diagnosis of the macular degeneration was analyzed and displayed by the Receiver Operating Curve (ROC). The maculae and the peripheral retina of 73 normal eyes and of 26 eyes afflicted by an early stage of non-exudative senile macular degeneration were characterized by time-correlation functions and analyzed in terms of characteristic decay times and apparent size distributions. The characteristics of the obtained time-correlation functions of the eyes afflicted with nonexudative macular degeneration and of normal eyes differed significantly, which could be referred to a significant change of the nano- and microstructure of the investigated pathologic maculas. Photon-correlation spectroscopy is able to assess the macromolecular and microstructural aberrations in the macula afflicted by non-exudative, senile macular degeneration. It has been demonstrated that macromolecules of this disease show a characteristic abnormal behavior in the macula.

  13. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    International Nuclear Information System (INIS)

    Pugliese, Francesca; Krestin, Gabriel P.; Mollet, Nico R.A.; DeFeyter, Pim J.; Runza, Giuseppe; Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo; Malagutti, Patrizia; Cademartiri, Filippo

    2006-01-01

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as ≥ 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  14. Multiparametric Functional MRI: Non-Invasive Imaging of Inflammation and Edema Formation after Kidney Transplantation in Mice.

    Directory of Open Access Journals (Sweden)

    Katja Hueper

    Full Text Available Kidney transplantation (ktx in mice is used to learn about rejection and to develop new treatment strategies. Past studies have mainly been based on histological or molecular biological methods. Imaging techniques to monitor allograft pathology have rarely been used.Here we investigated mice after isogenic and allogenic ktx over time with functional MRI with diffusion-weighted imaging (DWI and mapping of T2-relaxation time (T2-mapping to assess graft inflammation and edema formation. To characterize graft pathology, we used PAS-staining, counted CD3-positive T-lymphocytes, analyzed leukocytes by means flow cytometry.DWI revealed progressive restriction of diffusion of water molecules in allogenic kidney grafts. This was paralleled by enhanced infiltration of the kidney by inflammatory cells. Changes in tissue diffusion were not seen following isogenic ktx. T2-times in renal cortex were increased after both isogenic and allogenic transplantation, consistent with tissue edema due to ischemic injury following prolonged cold ischemia time of 60 minutes. Lack of T2 increase in the inner stripe of the inner medulla in allogenic kidney grafts matched loss of tubular autofluorescence and may result from rejection-driven reductions in tubular water content due to tubular dysfunction and renal functional impairment.Functional MRI is a valuable non-invasive technique for monitoring inflammation, tissue edema and tubular function. It permits on to differentiate between acute rejection and ischemic renal injury in a mouse model of ktx.

  15. Non invasive diagnostic methods for better screening of peripheral arterial disease.

    Science.gov (United States)

    Nirala, Neelamshobha; Periyasamy, R; Kumar, Awanish

    2018-05-16

    Peripheral arterial disease (PAD) is a common circulatory problem in which narrowed arteries reduce blood flow to extremities usually legs. It does not receive enough blood flow to keep up with demand. This causes symptoms, most notably leg pain while walking which is known as claudication. It is a common manifestation of type II Diabetes, but the relationship between other vascular diseases and lower limb (LL)-PAD has been poorly understood and investigated. When assessing a patient with clinically LLPAD, two questions are in order to establish a diagnosis: one is non-invasive testing and other is invasive. Invasive methods are painful and get so bad that some people need to have a leg surgery. People with Diabetes are at increased risk for amputation and it is used only when the damage is very severe. Diagnosis of LLPAD begins with a physical examination, patient history, certain questionnaire and non invasive mode of diagnosis is started for the screening of patients. Clinicians check for weak pulses in the legs and then decide for further diagnosis. Paper discusses the prevalence of LLPAD worldwide and in India along with the clinical effectiveness and limitations of these methods in case of Diabetes. The focus of this review is to discuss only those non invasive methods which are widely used for screening of LLPAD like Ankle brachial index (ABI), Toe brachial Index (TBI), and use of photoplethysmogram (PPG) specially in case of Diabetic patients. Also, this paper gives an overview of the work done using ABI, TBI, and PPG for detection of LLPAD. These tests are not painful and could be performed in a cost-effective manner to avoid delays in screening/diagnosis and also reduce costs. Copyright © 2018. Published by Elsevier Inc.

  16. Contribution of mechanical unloading to trabecular bone loss following non-invasive knee injury in mice.

    Science.gov (United States)

    Anderson, Matthew J; Diko, Sindi; Baehr, Leslie M; Baar, Keith; Bodine, Sue C; Christiansen, Blaine A

    2016-10-01

    Development of osteoarthritis commonly involves degeneration of epiphyseal trabecular bone. In previous studies, we observed 30-44% loss of epiphyseal trabecular bone (BV/TV) from the distal femur within 1 week following non-invasive knee injury in mice. Mechanical unloading (disuse) may contribute to this bone loss; however, it is unclear to what extent the injured limb is unloaded following injury, and whether disuse can fully account for the observed magnitude of bone loss. In this study, we investigated the contribution of mechanical unloading to trabecular bone changes observed following non-invasive knee injury in mice (female C57BL/6N). We investigated changes in gait during treadmill walking, and changes in voluntary activity level using Open Field analysis at 4, 14, 28, and 42 days post-injury. We also quantified epiphyseal trabecular bone using μCT and weighed lower-limb muscles to quantify atrophy following knee injury in both ground control and hindlimb unloaded (HLU) mice. Gait analysis revealed a slightly altered stride pattern in the injured limb, with a decreased stance phase and increased swing phase. However, Open Field analysis revealed no differences in voluntary movement between injured and sham mice at any time point. Both knee injury and HLU resulted in comparable magnitudes of trabecular bone loss; however, HLU resulted in considerably more muscle loss than knee injury, suggesting another mechanism contributing to bone loss following injury. Altogether, these data suggest that mechanical unloading likely contributes to trabecular bone loss following non-invasive knee injury, but the magnitude of this bone loss cannot be fully explained by disuse. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1680-1687, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. Non-Invasive Seismic Methods for Earthquake Site Classification Applied to Ontario Bridge Sites

    Science.gov (United States)

    Bilson Darko, A.; Molnar, S.; Sadrekarimi, A.

    2017-12-01

    How a site responds to earthquake shaking and its corresponding damage is largely influenced by the underlying ground conditions through which it propagates. The effects of site conditions on propagating seismic waves can be predicted from measurements of the shear wave velocity (Vs) of the soil layer(s) and the impedance ratio between bedrock and soil. Currently the seismic design of new buildings and bridges (2015 Canadian building and bridge codes) requires determination of the time-averaged shear-wave velocity of the upper 30 metres (Vs30) of a given site. In this study, two in situ Vs profiling methods; Multichannel Analysis of Surface Waves (MASW) and Ambient Vibration Array (AVA) methods are used to determine Vs30 at chosen bridge sites in Ontario, Canada. Both active-source (MASW) and passive-source (AVA) surface wave methods are used at each bridge site to obtain Rayleigh-wave phase velocities over a wide frequency bandwidth. The dispersion curve is jointly inverted with each site's amplification function (microtremor horizontal-to-vertical spectral ratio) to obtain shear-wave velocity profile(s). We apply our non-invasive testing at three major infrastructure projects, e.g., five bridge sites along the Rt. Hon. Herb Gray Parkway in Windsor, Ontario. Our non-invasive testing is co-located with previous invasive testing, including Standard Penetration Test (SPT), Cone Penetration Test and downhole Vs data. Correlations between SPT blowcount and Vs are developed for the different soil types sampled at our Ontario bridge sites. A robust earthquake site classification procedure (reliable Vs30 estimates) for bridge sites across Ontario is evaluated from available combinations of invasive and non-invasive site characterization methods.

  18. Non- invasive in vivo analysis of a murine aortic graft using high resolution ultrasound microimaging

    International Nuclear Information System (INIS)

    Rowinska, Zuzanna; Zander, Simone; Zernecke, Alma; Jacobs, Michael; Langer, Stephan; Weber, Christian; Merx, Marc W.; Koeppel, Thomas A.

    2012-01-01

    Introduction: As yet, murine aortic grafts have merely been monitored histopathologically. The aim of our study was to examine how these grafts can be monitored in vivo and non-invasively by using high-resolution ultrasound microimaging to evaluate function and morphology. A further aim was to prove if this in vivo monitoring can be correlated to immunohistological data that indicates graft integrity. Methods: Murine infrarenal aortic isografts were orthotopically transplanted into 14 female mice (C57BL/6-Background) whereas a group of sham-operated animals (n = 10) served as controls. To assess the graft morphology and hemodynamics, we examined the mice over a post-operative period of 8 weeks with a sophisticated ultrasound system (Vevo 770, Visual Sonics). Results: The non-invasive graft monitoring was feasible in all transplanted mice. We could demonstrate a regular post-transplant graft function and morphology, such as anterior/posterior wall displacement and wall thickness. Mild alterations of anterior wall motion dynamics could only be observed at the site of distal graft anastomosis (8 weeks after grafting (transplant vs. sham mice: 0.02 mm ± 0.01 vs. 0.03 mm ± 0.01, p < 0.05). However, the integrity of the entire graft wall could be confirmed by histopathological evaluation of the grafts. Conclusions: With regard to graft patency, function and morphology, high resolution ultrasound microimaging has proven to be a valuable tool for longitudinal, non-invasive, in vivo graft monitoring in this murine aortic transplantation model. Consequently, this experimental animal model provides an excellent basis for molecular and pharmacological studies using genetically engineered mice.

  19. Non-invasive therapy for the prevention of moist desquamation following β-radiation exposure

    International Nuclear Information System (INIS)

    Ma, L.; Wilcock, S.; Rezvani, M.; Hsia, C.

    2003-01-01

    Full text: In an environment of potential nuclear mishap, effective therapies are lacking for radiation-induced skin burns. In this report we describe an effective, non-invasive therapy for post acute radiation exposure based on skin compression. A pig skin model of β-radiation-induced moist desquamation (MD) was employed in this study. Exposure to 30 Gy was used to induce skin lesions involving >80% MD in prescribed test sites on flank skin of female Large White pigs (n 18 per flank). The animals' left flank was placed under pressure from the weight of the pig's own body for 3 hours, immediately following radiation exposure. The right flank served as control, and was not subject to compression following irradiation. Percentage differences in MD were measured between sites on both flanks based on the the area of the test site containing 50% MD (severe) as determined by clinical assessment using blinded observers. The incidence of MD was significantly higher on the uncompressed right flank as compared to the compressed left flank (p < 0.005). A 61% and 45% reduction of MD was observed in both total and severe MD, respectively, during the 8-week study period. Radiation-induced MD was significantly reduced by immediate, mild skin compression (approx. 1.5 psi) for 3 hours immediately following exposure. This observation suggests that skin lesion development from radiation-induced oxidative damage cascades may be modulated non-invasively. Understanding the mechanism(s) at work and developing devices based on this non-invasive therapeutic principle may provide a novel treatment for consequent skin injury in radiation oncology, cosmetic and therapeutic UV, laser, glycolic and derm abrasion procedures

  20. The immunological response created by interstitial and non-invasive laser immunotherapy

    Science.gov (United States)

    Bahavar, Cody F.; Zhou, Feifan; Hasanjee, Aamr M.; West, Connor L.; Nordquist, Robert E.; Hode, Tomas; Liu, Hong; Chen, Wei R.

    2015-03-01

    Laser immunotherapy (LIT) is an innovative cancer modality that uses laser irradiation and immunological stimulation to treat late-stage, metastatic cancers. LIT can be performed through either interstitial or non-invasive laser irradiation. Although LIT is still in development, recent clinical trials have shown that it can be used to successfully treat patients with late-stage breast cancer and melanoma. The development of LIT has been focused on creating an optimal immune response created by irradiating the tumor. One important factor that could enhance the immune response is the duration of laser irradiation. Irradiating the tumor for a shorter or longer amount of time could weaken the immune response created by LIT. Another factor that could weaken this immune response is the proliferation of regulatory T cells (TRegs) in response to the laser irradiation. However, low dose cyclophosphamide (CY) can help suppress the proliferation of TRegs and help create a more optimal immune response. An additional factor that could weaken the effectiveness of LIT is the selectivity of the laser. If LIT is performed non-invasively, then deeply embedded tumors and highly pigmented skin could cause an uneven temperature distribution inside the tumor. To solve this problem, an immunologically modified carbon nanotube system was created by using an immunoadjuvant known as glycated chitosan (GC) as a surfactant for single-walled carbon nanotubes (SWNTs) to immunologically modify SWNTs. SWNT-GC retains the optical properties of SWNTs and the immunological functions of GC to help increase the selectivity of the laser and create a more optimal immune response. In this preliminary study, tumor-bearing rats were treated with LIT either interstitially by an 805-nm laser with GC and low-dose CY, or non-invasively by a 980-nm laser with SWNT-GC. The goal was to observe the effects of CY on the immune response induced by LIT and to also determine the effect of irradiation duration for

  1. [A comparison of leak compensation in six acute care ventilators during non-invasive ventilation].

    Science.gov (United States)

    Hu, X S; Wang, Y; Wang, Z T; Yan, P; Zhang, X G; Zhao, S F; Xie, F; Gu, H J; Xie, L X

    2017-02-12

    Objective: To compare the ability of leak compensation in 6 medical ventilators during non-invasive ventilation. Methods: Six medical ventilators were selected, including 3 non-invasive ventilators (V60, Flexo and Stellar150), and 3 invasive ventilators(Avea, Servo I and BellaVist). Using a lung simulator, the ability of leak compensation was evaluated during triggering and cycling in 2 respiratory mechanics conditions (high airway resistance condition and high elastance resistance condition), and each condition was performed under 2 PEEP levels (4, and 8 cmH(2)O, 1 mmHg=0.098 kPa) at 4 air leak level conditions (L0: 2-3 L/min, L1: 8-10 L/min, L2: 22-27 L/min, L3: 35-40 L/min). Results: In the high elastance resistance condition (L2, L3)with different leak levels, the number of auto-triggering and miss-triggering of the non-invasive ventilator Flexo was significantly less than those of the others (L2: 1, 1; L3: 1.67, 1.33, P ventilators ( P ventilators (1, 0.67, 0, P ventilators in both high airway resistance and high elastance resistance conditions with L0 and L1 leak levels and PEEP levels [ARDS, PEEP=4: (109.8±1.8) ms, (112.0±0.6) ms; ARDS, PEEP=8: (103.1±0.7) ms, (109.7±0.7) ms; COPD, PEEP=4: (207.3±1.1) ms, (220.8±1.1) ms; COPD, PEEP=8: (195.6±6.7) ms, (200.0±1.2) ms , P ventilators could be synchronized, among which V60, Stellar150 and Flexo presented a good performance features in specific conditions.

  2. Prediction of human core body temperature using non-invasive measurement methods.

    Science.gov (United States)

    Niedermann, Reto; Wyss, Eva; Annaheim, Simon; Psikuta, Agnes; Davey, Sarah; Rossi, René Michel

    2014-01-01

    The measurement of core body temperature is an efficient method for monitoring heat stress amongst workers in hot conditions. However, invasive measurement of core body temperature (e.g. rectal, intestinal, oesophageal temperature) is impractical for such applications. Therefore, the aim of this study was to define relevant non-invasive measures to predict core body temperature under various conditions. We conducted two human subject studies with different experimental protocols, different environmental temperatures (10 °C, 30 °C) and different subjects. In both studies the same non-invasive measurement methods (skin temperature, skin heat flux, heart rate) were applied. A principle component analysis was conducted to extract independent factors, which were then used in a linear regression model. We identified six parameters (three skin temperatures, two skin heat fluxes and heart rate), which were included for the calculation of two factors. The predictive value of these factors for core body temperature was evaluated by a multiple regression analysis. The calculated root mean square deviation (rmsd) was in the range from 0.28 °C to 0.34 °C for all environmental conditions. These errors are similar to previous models using non-invasive measures to predict core body temperature. The results from this study illustrate that multiple physiological parameters (e.g. skin temperature and skin heat fluxes) are needed to predict core body temperature. In addition, the physiological measurements chosen in this study and the algorithm defined in this work are potentially applicable as real-time core body temperature monitoring to assess health risk in broad range of working conditions.

  3. [Reflections on the use of non-invasive mechanical ventilation in acute respiratory failure].

    Science.gov (United States)

    Scala, Raffaele

    2012-12-01

    Given its prevalence into the clinical practice, non-invasive ventilation (NIV) can be included among the cornerstones of medicine. Just think of the acute applications of NIV which are in constant expansion, from COPD exacerbation to severe de novo hypoxemia, from postoperative distress to extra-hospital use in acute pulmonary edema, from ongoing support of interventional procedures to delicate strategies for end of life in terminally ill oncologic and non-oncologic patients. The thought should be focused on how, by whom, where and to whom is delivered this mode of artificial ventilation to avoid the risk of trivialization and flattening.

  4. Non-invasive assessment of in-vitro embryo quality to improve transfer success

    DEFF Research Database (Denmark)

    Højbøge, Tina Rødgaard; Heegaard, Peter M. H.; Callesen, Henrik

    2015-01-01

    Although IVF has been performed routinely for many years to help couples with fertility problems and in relation to modern breeding of farm animals, pregnancy rates after transfer to a recipient have not improved during the last decade. Early prediction of the viability of in-vitro developed...... subjectively. The simple morphological approach is, however, inadequate for the prediction of embryo quality, and several studies have focused on developing new non-invasive methods using molecular approaches based particularly on proteomics, metabolomics and most recently small non-coding RNA, including micro...

  5. Non-invasive bleaching of the human lens by femtosecond laser photolysis

    DEFF Research Database (Denmark)

    Kessel, L.; Eskildsen, Lars; Poel, Mike van der

    2010-01-01

    . Reducing blindness from cataract requires solutions that can be applied outside operating theatres. Cataract is a protein conformational disease characterized by accumulation of light absorbing, fluorescent and scattering protein aggregates. The aim of the study was to investigate whether these compounds...... by a non-invasive procedure based on femtosecond laser photolysis. Cataract is a disease associated with old age. At the current technological stage, lens aging is delayed but with a treatment covering the entire lens volume complete optical rejuvenation is expected. Thus, femtosecond photolysis has...

  6. CARDIAC TRANSPLANT REJECTION AND NON-INVASIVE COMON CAROTID ARTERY WALL FUNCTIONAL INDICES

    Directory of Open Access Journals (Sweden)

    A. O. Shevchenko

    2015-01-01

    Full Text Available Allograft rejection would entail an increase in certain blood biomarkers and active substances derived from activated inflammatory cells which could influence entire vascular endothelial function and deteriorate arterial wall stiffness. We propose that carotid wall functional indices measured with non-invasive ultrasound could we valuable markers of the subclinical cardiac allograft rejection. Aim. Our goal was to analyze the clinical utility of functional common carotid wall (CCW variables measured with high-resolution Doppler ultrasound as a non-invasive screening tool for allograft rejection in cardiac transplant patients (pts. Methods. One hundred and seventy one pts included 93 cardiac recipients, 30 dilated cardiomyopathy waiting list pts, and 48 stable coronary artery disease (SCAD pts without decompensated heart failure were included. Along with resistive index (Ri, pulsative index (Pi, and CCW intima-media thickness (IMT, CCW rigidity index (iRIG was estimated using empirical equation. Non-invasive evaluation was performed in cardiac transplant recipients prior the endomyo- cardial biopsy. Results. Neither of Ri, Pi, or CCW IMT were different in studied subgroups. iRIG was signifi- cantly lower in SCAD pts when compared to the dilated cardiomyopathy subgroup. The later had similar values with cardiac transplant recipients without rejection. Antibody-mediated and cellular rejection were found in 22 (23.7% and 17 (18.3% cardiac recipients, respectively. Mean iRIG in pts without rejection was significantly lower in comparison to antibody-mediated rejection and cell-mediated (5514.7 ± 2404.0 vs 11856.1 ± 6643.5 and 16071.9 ± 10029.1 cm/sec2, respectively, p = 0.001. Area under ROC for iRIG was 0.90 ± 0.03 units2. Analysis showed that iRIG values above estimated treshold 7172 cm/sec2 suggested relative risk of any type of rejection 17.7 (95%CI = 6.3–49.9 sensitivity 80.5%, specificity – 81.1%, negative predictive value – 84

  7. Portable non-invasive brain-computer interface: challenges and opportunities of optical modalities

    Science.gov (United States)

    Scholl, Clara A.; Hendrickson, Scott M.; Swett, Bruce A.; Fitch, Michael J.; Walter, Erich C.; McLoughlin, Michael P.; Chevillet, Mark A.; Blodgett, David W.; Hwang, Grace M.

    2017-05-01

    The development of portable non-invasive brain computer interface technologies with higher spatio-temporal resolution has been motivated by the tremendous success seen with implanted devices. This talk will discuss efforts to overcome several major obstacles to viability including approaches that promise to improve spatial and temporal resolution. Optical approaches in particular will be highlighted and the potential benefits of both Blood-Oxygen Level Dependent (BOLD) and Fast Optical Signal (FOS) will be discussed. Early-stage research into the correlations between neural activity and FOS will be explored.

  8. Validation of a non-invasive arterial monitor GATE model for PET

    Energy Technology Data Exchange (ETDEWEB)

    Giansiracusa, P.J., E-mail: pgia@student.unimelb.edu.au [School of Physics, The University of Melbourne, Parkville (Australia); Peake, D.J. [DETECT Australia, Bundoora (Australia); Sobott, B.A. [School of Physics, The University of Melbourne, Parkville (Australia); O' Keefe, G. [The Austin PET Centre, Austin Hospital, Heidelberg (Australia); Rassool, R.P. [School of Physics, The University of Melbourne, Parkville (Australia)

    2014-02-11

    The Non-Invasive Arterial Monitor (NIAM3) is an SiPM based detector system designed for calibrating Positron-Emission Tomography (PET) images without invasive blood sampling. By imaging the radial and ulnar arteries in the wrist directly with a custom built PET system the resultant PET images can be calibrated. An integral step in the development of a complex detector system is the creation of a model which accurately reflects the physical reality being studied. This paper describes the development of a simulation for NIAM which shows good agreement between the model and physical detector setup.

  9. Method for Non-Invasive Determination of Chemical Properties of Aqueous Solutions

    Science.gov (United States)

    Todd, Paul W. (Inventor); Jones, Alan (Inventor); Thomas, Nathan A. (Inventor)

    2016-01-01

    A method for non-invasively determining a chemical property of an aqueous solution is provided. The method provides the steps of providing a colored solute having a light absorbance spectrum and transmitting light through the colored solute at two different wavelengths. The method further provides the steps of measuring light absorbance of the colored solute at the two different transmitted light wavelengths, and comparing the light absorbance of the colored solute at the two different wavelengths to determine a chemical property of an aqueous solution.

  10. Dielectric spectroscopy for non-invasive monitoring of epithelial cell differentiation within three-dimensional scaffolds

    International Nuclear Information System (INIS)

    Daoud, Jamal; Tabrizian, Maryam; Asami, Koji; Rosenberg, Lawrence

    2012-01-01

    In this study, we introduce a cellular differentiation cellular model based on dielectric spectroscopy that characterizes epithelial differentiation processes. Non-invasive cellular monitoring was achieved within a three-dimensional microenvironment consisting of a cell-containing collagen I gel seeded onto microfabricated scaffolds. In this proof-of-concept investigation, Madin–Darby canine kidney cells were cultured within microfabricated, geometrically controlled scaffolds and allowed us to differentiate to hollow cyst-like structures. This transformation within the three-dimensional environment is monitored and characterized through dielectric spectroscopy while maintaining cell culture in vitro. (paper)

  11. Non-invasive brain stimulation to promote motor and functional recovery following spinal cord injury

    Directory of Open Access Journals (Sweden)

    Aysegul Gunduz

    2017-01-01

    Full Text Available We conducted a systematic review of studies using non-invasive brain stimulation (NIBS: repetitive transcranial magnetic stimulation (rTMS and transcranial direct current stimulation (tDCS as a research and clinical tool aimed at improving motor and functional recovery or spasticity in patients following spinal cord injury (SCI under the assumption that if the residual corticospinal circuits could be stimulated appropriately, the changes might be accompanied by functional recovery or an improvement in spasticity. This review summarizes the literature on the changes induced by NIBS in the motor and functional recovery and spasticity control of the upper and lower extremities following SCI.

  12. Experimental bifurcation analysis of an impact oscillator - Tuning a non-invasive control scheme

    DEFF Research Database (Denmark)

    Bureau, Emil; Schilder, Frank; Santos, Ilmar

    2013-01-01

    We investigate a non-invasive, locally stabilizing control scheme necessary for an experimental bifurcation analysis. Our test-rig comprises a harmonically forced impact oscillator with hardening spring nonlinearity controlled by electromagnetic actuators, and serves as a prototype...... for electromagnetic bearings and other machinery with build-in actuators. We propose a sequence of experiments that allows one to choose optimal control-gains, filter parameters and settings for a continuation method without a priori study of a model. Depending on the algorithm for estimating the Jacobian required...

  13. Non-invasive electrocardiogram detection of in vivo zebrafish embryos using electric potential sensors

    Science.gov (United States)

    Rendon-Morales, E.; Prance, R. J.; Prance, H.; Aviles-Espinosa, R.

    2015-11-01

    In this letter, we report the continuous detection of the cardiac electrical activity in embryonic zebrafish using a non-invasive approach. We present a portable and cost-effective platform based on the electric potential sensing technology, to monitor in vivo electrocardiogram activity from the zebrafish heart. This proof of principle demonstration shows how electrocardiogram measurements from the embryonic zebrafish may become accessible by using electric field detection. We present preliminary results using the prototype, which enables the acquisition of electrophysiological signals from in vivo 3 and 5 days-post-fertilization zebrafish embryos. The recorded waveforms show electrocardiogram traces including detailed features such as QRS complex, P and T waves.

  14. Open source non-invasive prenatal testing platform and its performance in a public health laboratory

    DEFF Research Database (Denmark)

    Johansen, Peter; Richter, Stine R; Balslev-Harder, Marie

    2016-01-01

    OBJECTIVE: The objective of this study was to introduce non-invasive prenatal testing (NIPT) for fetal autosomal trisomies and gender in a Danish public health setting, using semi-conductor sequencing and published open source scripts for analysis. METHODS: Plasma-derived DNA from a total of 375...... correlation (R(2)  = 0.72) to Y-chromosomal content of the male fetus samples. DISCUSSION: We have implemented NIPT into Danish health care using published open source scripts for autosomal aneuploidy detection and fetal DNA fraction estimation showing excellent false negative and false positive rates. Seq...

  15. Measurement of Non-Invasive Blood Glucose Level Based Sensor Color TCS3200 and Arduino

    Science.gov (United States)

    Kurniadi Wardana, Humaidillah; Indahwati, Elly; Arifah Fitriyah, Lina

    2018-04-01

    Design and measurement of Arduino-based urinary (non-invasive) urine glucose using RGB tcs3200 sensor. This research was conducted by making use of the urine in diabetes patients detected by sensor colours then measured levels of colour based on the RGB colour of the urine of diabetics. The detection is done on 4 urine samples with each consisting of 3 diabetics and 1 non-diabetics. Equipment used in this research, among others, Arduino Uno, colour sensor tcs3200, LCD 16x4. The results showed that the detection of RGB values in diabetics 230 with blue and not diabetics 200 with red.

  16. Non-invasive imaging of retinal blood flow in myeloproliferative neoplasms

    DEFF Research Database (Denmark)

    Willerslev, Anne; Hansen, Mathias M; Klefter, Oliver Niels

    2017-01-01

    PURPOSE: To study the circulation in the retinal vessels in patients with blood dyscrasia due to myeloproliferative neoplasms using non-invasive retinal imaging. METHODS: Prospective consecutive case series of seven treatment-naïve patients with chronic myeloid leukaemia (n = 2), polycythemia vera...... present at baseline in patients with chronic myeloid leukaemia and were replaced by normal patterns at follow-up. Retinopathy, in the form of cotton-wool spots and retinal haemorrhages, was found at presentation in the two patients with chronic myeloid leukaemia and in one patient with polycythemia vera...

  17. Non-invasive imaging methods applied to neo- and paleontological cephalopod research

    Science.gov (United States)

    Hoffmann, R.; Schultz, J. A.; Schellhorn, R.; Rybacki, E.; Keupp, H.; Gerden, S. R.; Lemanis, R.; Zachow, S.

    2013-11-01

    Several non-invasive methods are common practice in natural sciences today. Here we present how they can be applied and contribute to current topics in cephalopod (paleo-) biology. Different methods will be compared in terms of time necessary to acquire the data, amount of data, accuracy/resolution, minimum-maximum size of objects that can be studied, of the degree of post-processing needed and availability. Main application of the methods is seen in morphometry and volumetry of cephalopod shells in order to improve our understanding of diversity and disparity, functional morphology and biology of extinct and extant cephalopods.

  18. Non-invasive index of liver fibrosis induced by alcohol, thioacetamide and schistosomal infection in mice

    Directory of Open Access Journals (Sweden)

    El-Beltagy Doha M

    2010-06-01

    Full Text Available Abstract Background Non invasive approaches will likely be increasing utilized to assess liver fibrosis. This work provides a new non invasive index to predict liver fibrosis induced in mice. Methods Fibrosis was generated by thioacetamide (TAA, chronic intake of ethanol, or infection with S. mansoni in 240 mice. Both progression and regression of fibrosis (after treatment with silymarin and/or praziquantel were monitored. The following methods were employed: (i The METAVIR system was utilized to grade and stage liver inflammation and fibosis; (ii Determination of hepatic hydroxyproline and collagen; and (iii Derivation of a new hepatic fibrosis index from the induced changes, and its prospective validation in a group of 70 mice. Results The index is composed of 4 serum variable including total proteins, γ-GT, bilirubin and reduced glutathione (GSH, measured in diseased, treated and normal mice. These parameters were highly correlated with both the histological stage and the grade. They were combined in a logarithmic formula, which non-invasively scores the severity of liver fibrosis through a range (0 to 2, starting with healthy liver (corresponding to stage 0 to advanced fibrosis (corresponding stage 3.Receiver operating characteristic curves (ROC for the accuracy of the index to predict the histological stages demonstrated that the areas under the curve (AUC were 0.954, 0.979 and 0.99 for index values corresponding to histological stages 1, 2 and 3, respectively. Also, the index was correlated with stage and grade, (0.947 and 0.859, respectively. The cut off values that cover the range between stages 0-1, 1-2 and 2-3 are 0.4, 1.12 and 1.79, respectively. The results in the validation group confirmed the accuracy of the test. The AUROC was 0.869 and there was good correlation with the stage of fibrosis and grade of inflammation. Conclusion The index fulfils the basic criteria of non-invasive marker of liver fibrosis since it is liver

  19. Non-invasive estimation of dissipation from non-equilibrium fluctuations in chemical reactions.

    Science.gov (United States)

    Muy, S; Kundu, A; Lacoste, D

    2013-09-28

    We show how to extract an estimate of the entropy production from a sufficiently long time series of stationary fluctuations of chemical reactions. This method, which is based on recent work on fluctuation theorems, is direct, non-invasive, does not require any knowledge about the underlying dynamics and is applicable even when only partial information is available. We apply it to simple stochastic models of chemical reactions involving a finite number of states, and for this case, we study how the estimate of dissipation is affected by the degree of coarse-graining present in the input data.

  20. Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility.

    Science.gov (United States)

    Cutajar, Marica; Thomas, David L; Hales, Patrick W; Banks, T; Clark, Christopher A; Gordon, Isky

    2014-06-01

    To investigate the reproducibility of arterial spin labelling (ASL) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and quantitatively compare these techniques for the measurement of renal blood flow (RBF). Sixteen healthy volunteers were examined on two different occasions. ASL was performed using a multi-TI FAIR labelling scheme with a segmented 3D-GRASE imaging module. DCE MRI was performed using a 3D-FLASH pulse sequence. A Bland-Altman analysis was used to assess repeatability of each technique, and determine the degree of correspondence between the two methods. The overall mean cortical renal blood flow (RBF) of the ASL group was 263 ± 41 ml min(-1) [100 ml tissue](-1), and using DCE MRI was 287 ± 70 ml min(-1) [100 ml tissue](-1). The group coefficient of variation (CVg) was 18 % for ASL and 28 % for DCE-MRI. Repeatability studies showed that ASL was more reproducible than DCE with CVgs of 16 % and 25 % for ASL and DCE respectively. Bland-Altman analysis comparing the two techniques showed a good agreement. The repeated measures analysis shows that the ASL technique has better reproducibility than DCE-MRI. Difference analysis shows no significant difference between the RBF values of the two techniques. Reliable non-invasive monitoring of renal blood flow is currently clinically unavailable. Renal arterial spin labelling MRI is robust and repeatable. Renal dynamic contrast-enhanced MRI is robust and repeatable. ASL blood flow values are similar to those obtained using DCE-MRI.

  1. DEGRO practical guidelines: radiotherapy of breast cancer II. Radiotherapy of non-invasive neoplasia of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Souchon, R. [University Hospital Tuebingen, Klinik fuer Radioonkologie, Tuebingen (Germany); Sautter-Bihl, M.L. [Municipal Hospital Karlsruhe, Karlsruhe (Germany); Sedlmayer, F. [LKH Salzburg, Paracelsus Medical University Hospital, Salzburg (Austria); Budach, W. [University Hospital Duesseldorf, Duesseldorf (Germany); Dunst, J. [University Hospital Schleswig-Holstein, Luebeck (Germany); Feyer, P. [Klinikum Neukoelln, Berlin (Germany); Fietkau, R.; Sauer, R. [University Hospital Erlangen, Erlangen (Germany); Harms, W. [St. Clara Hospital, Basel (Switzerland); Wenz, F. [University Hospital Mannheim, Mannheim (Germany); Haase, W.

    2014-01-15

    To complement and update the 2007 practice guidelines of the breast cancer expert panel of the German Society of Radiation Oncology (DEGRO) for radiotherapy (RT) of breast cancer. Owing to its growing clinical relevance, in the current version, a separate paper is dedicated to non-invasive proliferating epithelial neoplasia of the breast. In addition to the more general statements of the German interdisciplinary S3 guidelines, this paper is especially focused on indication and technique of RT in addition to breast conserving surgery. The DEGRO expert panel performed a comprehensive survey of the literature comprising recently published data from clinical controlled trials, systematic reviews as well as meta-analyses, referring to the criteria of evidence-based medicine yielding new aspects compared to 2005 and 2007. The literature search encompassed the period 2008 to September 2012 using databases of PubMed and Guidelines International Network (G-I-N). Search terms were ''non invasive breast cancer'', ''ductal carcinoma in situ, ''dcis'', ''borderline breast lesions'', ''lobular neoplasia'', ''radiotherapy'' and ''radiation therapy''. In addition to the more general statements of the German interdisciplinary S3 guidelines, this paper is especially focused on indications of RT and decision making of non-invasive neoplasia of the breast after surgery, especially ductal carcinoma in situ. Among different non-invasive neoplasia of the breast only the subgroup of pure ductal carcinoma in situ (DCIS; synonym ductal intraepithelial neoplasia, DIN) is considered for further recurrence risk reduction treatment modalities after complete excision of DCIS, particularly RT following breast conserving surgery (BCS), in order to avoid a mastectomy. About half of recurrences are invasive cancers. Up to 50?% of all recurrences require salvage mastectomy

  2. Non-invasive monitoring of therapeutic carbon ion beams in a homogeneous phantom by tracking of secondary ions

    Science.gov (United States)

    Gwosch, K.; Hartmann, B.; Jakubek, J.; Granja, C.; Soukup, P.; Jäkel, O.; Martišíková, M.

    2013-06-01

    Radiotherapy with narrow scanned carbon ion beams enables a highly accurate treatment of tumours while sparing the surrounding healthy tissue. Changes in the patient’s geometry can alter the actual ion range in tissue and result in unfavourable changes in the dose distribution. Consequently, it is desired to verify the actual beam delivery within the patient. Real-time and non-invasive measurement methods are preferable. Currently, the only technically feasible method to monitor the delivered dose distribution within the patient is based on tissue activation measurements by means of positron emission tomography (PET). An alternative monitoring method based on tracking of prompt secondary ions leaving a patient irradiated with carbon ion beams has been previously suggested. It is expected to help in overcoming the limitations of the PET-based technique like physiological washout of the beam induced activity, low signal and to allow for real-time measurements. In this paper, measurements of secondary charged particle tracks around a head-sized homogeneous PMMA phantom irradiated with pencil-like carbon ion beams are presented. The investigated energies and beam widths are within the therapeutically used range. The aim of the study is to deduce properties of the primary beam from the distribution of the secondary charged particles. Experiments were performed at the Heidelberg Ion Beam Therapy Center, Germany. The directions of secondary charged particles emerging from the PMMA phantom were measured using an arrangement of two parallel pixelated silicon detectors (Timepix). The distribution of the registered particle tracks was analysed to deduce its dependence on clinically important beam parameters: beam range, width and position. Distinct dependencies of the secondary particle tracks on the properties of the primary carbon ion beam were observed. In the particular experimental set-up used, beam range differences of 1.3 mm were detectable. In addition, variations

  3. Multi-frequency electrical impedance tomography as a non-invasive tool to characterize and monitor crop root systems

    Science.gov (United States)

    Weigand, Maximilian; Kemna, Andreas

    2017-02-01

    A better understanding of root-soil interactions and associated processes is essential in achieving progress in crop breeding and management, prompting the need for high-resolution and non-destructive characterization methods. To date, such methods are still lacking or restricted by technical constraints, in particular the charactization and monitoring of root growth and function in the field. A promising technique in this respect is electrical impedance tomography (EIT), which utilizes low-frequency (response in alternating electric-current fields due to electrical double layers which form at cell membranes. This double layer is directly related to the electrical surface properties of the membrane, which in turn are influenced by nutrient dynamics (fluxes and concentrations on both sides of the membranes). Therefore, it can be assumed that the electrical polarization properties of roots are inherently related to ion uptake and translocation processes in the root systems. We hereby propose broadband (mHz to hundreds of Hz) multi-frequency EIT as a non-invasive methodological approach for the monitoring and physiological, i.e., functional, characterization of crop root systems. The approach combines the spatial-resolution capability of an imaging method with the diagnostic potential of electrical-impedance spectroscopy. The capability of multi-frequency EIT to characterize and monitor crop root systems was investigated in a rhizotron laboratory experiment, in which the root system of oilseed plants was monitored in a water-filled rhizotron, that is, in a nutrient-deprived environment. We found a low-frequency polarization response of the root system, which enabled the successful delineation of its spatial extension. The magnitude of the overall polarization response decreased along with the physiological decay of the root system due to the stress situation. Spectral polarization parameters, as derived from a pixel-based Debye decomposition analysis of the multi

  4. A new electric method for non-invasive continuous monitoring of stroke volume and ventricular volume-time curves

    Directory of Open Access Journals (Sweden)

    Konings Maurits K

    2012-08-01

    Full Text Available Abstract Background In this paper a new non-invasive, operator-free, continuous ventricular stroke volume monitoring device (Hemodynamic Cardiac Profiler, HCP is presented, that measures the average stroke volume (SV for each period of 20 seconds, as well as ventricular volume-time curves for each cardiac cycle, using a new electric method (Ventricular Field Recognition with six independent electrode pairs distributed over the frontal thoracic skin. In contrast to existing non-invasive electric methods, our method does not use the algorithms of impedance or bioreactance cardiography. Instead, our method is based on specific 2D spatial patterns on the thoracic skin, representing the distribution, over the thorax, of changes in the applied current field caused by cardiac volume changes during the cardiac cycle. Since total heart volume variation during the cardiac cycle is a poor indicator for ventricular stroke volume, our HCP separates atrial filling effects from ventricular filling effects, and retrieves the volume changes of only the ventricles. Methods ex-vivo experiments on a post-mortem human heart have been performed to measure the effects of increasing the blood volume inside the ventricles in isolation, leaving the atrial volume invariant (which can not be done in-vivo. These effects have been measured as a specific 2D pattern of voltage changes on the thoracic skin. Furthermore, a working prototype of the HCP has been developed that uses these ex-vivo results in an algorithm to decompose voltage changes, that were measured in-vivo by the HCP on the thoracic skin of a human volunteer, into an atrial component and a ventricular component, in almost real-time (with a delay of maximally 39 seconds. The HCP prototype has been tested in-vivo on 7 human volunteers, using G-suit inflation and deflation to provoke stroke volume changes, and LVot Doppler as a reference technique. Results The ex-vivo measurements showed that ventricular filling

  5. Non-invasive diagnosis of sweat gland dysplasia using optical coherence tomography and reflectance confocal microscopy in a family with anhidrotic ectodermal dysplasia (Christ-Siemens-Touraine syndrome).

    Science.gov (United States)

    Reinholz, M; Gauglitz, G G; Giehl, K; Braun-Falco, M; Schwaiger, H; Schauber, J; Ruzicka, T; Berneburg, M; von Braunmühl, T

    2016-04-01

    Anhidrotic ectodermal dysplasia (AED) is an inherited syndrome, which originates mainly from genetic alteration of the ectodysplasin A (EDA) gene. It regularly affects the adnexa of the skin which results in a characteristic phenotype of the patients including hypo- or anhidrosis leading to severe disturbances in the regulation of body temperature. To prevent the development of the symptoms in early childhood promising therapeutic approaches are currently under clinical investigation. In this context, timely diagnosis of this genetic syndrome is crucial. The purpose of our study was the investigation of modern non-invasive imaging methods such as optical coherence tomography (OCT) and reflectance confocal microscopy (RCM) in the immediate diagnosis of AED. We examined a 3-year-old boy with the suspicion for an AED syndrome and his family members with RCM and OCT to document presence and characteristic features of sweat glands in comparison to non-affected individuals. The patient and the affected brother showed significantly reduced sweat glands in the imaging compared to the controls. The genetic analysis revealed a mutation of the EDA gene for hemizygosity previously associated with AED and the mother was revealed as the conductor of the genetic alteration. With the help of non-invasive imaging, we were able to detect sweat gland dysplasia in the affected family members without performing a biopsy which led us to the diagnosis of an AED. The application of modern dermatological imaging techniques might serve as valuable supplementary tools in the immediate, non-invasive diagnosis of genetic syndromes especially in newborns when early therapeutic approaches are planned. © 2015 European Academy of Dermatology and Venereology.

  6. Accuracy assessment of Tri-plane B-mode ultrasound for non-invasive 3D kinematic analysis of knee joints.

    Science.gov (United States)

    Masum, Md Abdullah; Pickering, Mark; Lambert, Andrew; Scarvell, Jennie; Smith, Paul

    2014-08-26

    Currently the clinical standard for measuring the motion of the bones in knee joints with sufficient precision involves implanting tantalum beads into the bones. These beads appear as high intensity features in radiographs and can be used for precise kinematic measurements. This procedure imposes a strong coupling between accuracy and invasiveness. In this paper, a tri-plane B-mode ultrasound (US) based non-invasive approach is proposed for use in kinematic analysis of knee joints in 3D space. The 3D analysis is performed using image processing procedures on the 2D US slices. The novelty of the proposed procedure and its applicability to the unconstrained 3D kinematic analysis of knee joints is outlined. An error analysis for establishing the method's feasibility is included for different artificial compositions of a knee joint phantom. Some in-vivo and in-vitro scans are presented to demonstrate that US scans reveal enough anatomical details, which further supports the experimental setup used using knee bone phantoms. The error between the displacements measured by the registration of the US image slices and the true displacements of the respective slices measured using the precision mechanical stages on the experimental apparatus is evaluated for translation and rotation in two simulated environments. The mean and standard deviation of errors are shown in tabular form. This method provides an average measurement precision of less than 0.1 mm and 0.1 degrees, respectively. In this paper, we have presented a novel non-invasive approach to measuring the motion of the bones in a knee using tri-plane B-mode ultrasound and image registration. In our study, the image registration method determines the position of bony landmarks relative to a B-mode ultrasound sensor array with sub-pixel accuracy. The advantages of our proposed system over previous techniques are that it is non-invasive, does not require the use of ionizing radiation and can be used conveniently if

  7. Neonatal non-invasive respiratory support: synchronised NIPPV, non-synchronised NIPPV or bi-level CPAP: what is the evidence in 2013?

    Science.gov (United States)

    Roberts, C T; Davis, P G; Owen, L S

    2013-01-01

    Nasal continuous positive airway pressure (NCPAP) has proven to be an effective mode of non-invasive respiratory support in preterm infants; however, many infants still require endotracheal ventilation, placing them at an increased risk of morbidities such as bronchopulmonary dysplasia. Several other modes of non-invasive respiratory support beyond NCPAP, including synchronised and non-synchronised nasal intermittent positive pressure ventilation (SNIPPV and nsNIPPV) and bi-level positive airway pressure (BiPAP) are now also available. These techniques require different approaches, and the exact mechanisms by which they act remain unclear. SNIPPV has been shown to reduce the rate of reintubation in comparison to NCPAP when used as post-extubation support, but the evidence for nsNIPPV and BiPAP in this context is less convincing. There is some evidence that NIPPV (whether synchronised or non-synchronised) used as primary respiratory support is beneficial, but the variation in study methodology makes this hard to translate confidently into clinical practice. There is currently no evidence to suggest a reduction in mortality or important morbidities such as bronchopulmonary dysplasia, with NIPPV or BiPAP in comparison to NCPAP, and there is a lack of appropriately designed studies in this area. This review discusses the different approaches and proposed mechanisms of action of SNIPPV, nsNIPPV and BiPAP, the challenges of applying the available evidence for these distinct modalities of non-invasive respiratory support to clinical practice, and possible areas of future research. © 2013 S. Karger AG, Basel.

  8. Non-invasive neurosensory testing used to diagnose and confirm successful surgical management of lower extremity deep distal posterior compartment syndrome

    Directory of Open Access Journals (Sweden)

    Guyton Gregory P

    2009-05-01

    Full Text Available Abstract Background Chronic exertional compartment syndrome (CECS is characterized by elevated pressures within a closed space of an extremity muscular compartment, causing pain and/or disability by impairing the neuromuscular function of the involved compartment. The diagnosis of CECS is primarily made on careful history and physical exam. The gold standard test to confirm the diagnosis of CECS is invasive intra-compartmental pressure measurements. Sensory nerve function is often diminished during symptomatic periods of CECS. Sensory nerve function can be documented with the use of non-painful, non-invasive neurosensory testing. Methods Non-painful neurosensory testing of the myelinated large sensory nerve fibers of the lower extremity were obtained with the Pressure Specified Sensory Device™ in a 25 year old male with history and invasive compartment pressures consistent with CECS both before and after running on a tread mill. After the patient's first operation to release the deep distal posterior compartment, the patient failed to improve. Repeat sensory testing revealed continued change in his function with exercise. He was returned to the operating room where a repeat procedure revealed that the deep posterior compartment was not completely released due to an unusual anatomic variant, and therefore complete release was accomplished. Results The patient's symptoms numbness in the plantar foot and pain in the distal calf improved after this procedure and his repeat sensory testing performed before and after running on the treadmill documented this improvement. Conclusion This case report illustrates the principal that non-invasive neurosensory testing can detect reversible changes in sensory nerve function after a provocative test and may be a helpful non-invasive technique to managing difficult cases of persistent lower extremity symptoms after failed decompressive fasciotomies for CECS. It can easily be performed before and after

  9. Pneumococci in biofilms are non-invasive: implications on nasopharyngeal colonization

    Directory of Open Access Journals (Sweden)

    Ryan Paul Gilley

    2014-11-01

    Full Text Available Streptococcus pneumoniae (the pneumococcus is an opportunistic pathogen that colonizes the human nasopharynx asymptomatically. Invasive pneumococcal disease develops following bacterial aspiration into the lungs. Pneumococci within the nasopharynx exist as biofilms, a growth phenotype characterized by surface attachment, encasement within an extracellular matrix, and antimicrobial resistance. Experimental evidence indicates that biofilm pneumococci are attenuated versus their planktonic counterpart. Biofilm pneumococci failed to cause invasive disease in experimentally challenged mice and in vitro were shown to be non-invasive despite being hyper-adhesive. This attenuated phenotype corresponds with observations that biofilm pneumococci elicit significantly less cytokine and chemokine production from host cells than their planktonic counterparts. Microarray and proteomic studies show that pneumococci within biofilms have decreased metabolism, less capsular polysaccharide, and reduced production of the pore-forming toxin pneumolysin. Biofilm pneumococci are predominately in the transparent phenotype, which has elevated cell wall phosphorylcholine, an adhesin subject to C-reactive protein mediated opsonization. Herein, we review these changes in virulence, interpret their impact on colonization and transmission, and discuss the notion that non-invasive biofilms are principal lifestyle of S. pneumoniae.

  10. Electro-resistive bands for non-invasive cardiac and respiration monitoring, a feasibility study

    International Nuclear Information System (INIS)

    Gargiulo, Gaetano D; Breen, Paul P; O’Loughlin, Aiden

    2015-01-01

    Continuous unobtrusive monitoring of tidal volume, particularly for critical care patients (i.e. neonates and patients in intensive care) during sleep studies and during daily activities, is still an unresolved monitoring need. Also a successful monitoring solution is yet to be proposed for continuous non-invasive cardiac stroke volume monitoring that is a novel clinical need. In this paper we present the feasibility study for a wearable, non-invasive, non-contact and unobtrusive sensor (embedded in a standard T-shirt) based on four electro-resistive bands that simultaneously monitors tidal volume and cardiac stroke volume changes. This low power sensor system (requires only 100 mW and accepts a wide power supply range up to ±18 V); thus the sensor can be easily embedded in existing wearable solutions (i.e. Holter monitors). Moreover, being contactless, it can be worn over bandages or electrodes, and as it does not rely over the integrity of the garment to work, it allows practitioners to perform procedures during monitoring. For this preliminary evaluation, one subject has worn the sensor over the period of 24 h (removing it only to shower); the accuracy of the tidal volume tested against a portable spirometer reported a precision of ±10% also during physical activity; accuracy tests for cardiac output (as it may require invasive procedure) have not been carried out in this preliminary trial. (note)

  11. Non-invasive optical detection of HBV based on serum surface-enhanced Raman spectroscopy

    Science.gov (United States)

    Zheng, Zuci; Wang, Qiwen; Weng, Cuncheng; Lin, Xueliang; Lin, Yao; Feng, Shangyuan

    2016-10-01

    An optical method of surface-enhanced Raman spectroscopy (SERS) was developed for non-invasive detection of hepatitis B surface virus (HBV). Hepatitis B virus surface antigen (HBsAg) is an established serological marker that is routinely used for the diagnosis of acute or chronic hepatitis B virus(HBV) infection. Utilizing SERS to analyze blood serum for detecting HBV has not been reported in previous literature. SERS measurements were performed on two groups of serum samples: one group for 50 HBV patients and the other group for 50 healthy volunteers. Blood serum samples are collected from healthy control subjects and patients diagnosed with HBV. Furthermore, principal components analysis (PCA) combined with linear discriminant analysis (LDA) were employed to differentiate HBV patients from healthy volunteer and achieved sensitivity of 80.0% and specificity of 74.0%. This exploratory work demonstrates that SERS serum analysis combined with PCA-LDA has tremendous potential for the non-invasive detection of HBV.

  12. Diagnosis of cirrhosis and portal hypertension: imaging, non-invasive markers of fibrosis and liver biopsy

    Science.gov (United States)

    Procopet, Bogdan

    2017-01-01

    Abstract The concept of ‘cirrhosis’ is evolving and it is now clear that compensated and decompensated cirrhosis are completely different in terms of prognosis. Furthermore, the term ‘advanced chronic liver disease (ACLD)’ better reflects the continuum of histological changes occurring in the liver, which continue to progress even after cirrhosis has developed, and might regress after removing the etiological factor causing the liver disease. In compensated ACLD, portal hypertension marks the progression to a stage with higher risk of clinical complication and requires an appropriate evaluation and treatment. Invasive tests to diagnose cirrhosis (liver biopsy) and portal hypertension (hepatic venous pressure gradient measurement and endoscopy) remain of crucial importance in several difficult clinical scenarios, but their need can be reduced by using different non-invasive tests in standard cases. Among non-invasive tests, the accepted use, major limitations and major benefits of serum markers of fibrosis, elastography and imaging methods are summarized in the present review. PMID:28533906

  13. Non-invasive peripheral nerve stimulation via focused ultrasound in vivo

    Science.gov (United States)

    Downs, Matthew E.; Lee, Stephen A.; Yang, Georgiana; Kim, Seaok; Wang, Qi; Konofagou, Elisa E.

    2018-02-01

    Focused ultrasound (FUS) has been employed on a wide range of clinical applications to safely and non-invasively achieve desired effects that have previously required invasive and lengthy procedures with conventional methods. Conventional electrical neuromodulation therapies that are applied to the peripheral nervous system (PNS) are invasive and/or non-specific. Recently, focused ultrasound has demonstrated the ability to modulate the central nervous system and ex vivo peripheral neurons. Here, for the first time, noninvasive stimulation of the sciatic nerve eliciting a physiological response in vivo is demonstrated with FUS. FUS was applied on the sciatic nerve in mice with simultaneous electromyography (EMG) on the tibialis anterior muscle. EMG signals were detected during or directly after ultrasound stimulation along with observable muscle contraction of the hind limb. Transecting the sciatic nerve downstream of FUS stimulation eliminated EMG activity during FUS stimulation. Peak-to-peak EMG response amplitudes and latency were found to be comparable to conventional electrical stimulation methods. Histology along with behavioral and thermal testing did not indicate damage to the nerve or surrounding regions. The findings presented herein demonstrate that FUS can serve as a targeted, safe and non-invasive alternative to conventional peripheral nervous system stimulation to treat peripheral neuropathic diseases in the clinic.

  14. Non-invasive spectroscopy of transfusable red blood cells stored inside sealed plastic blood-bags.

    Science.gov (United States)

    Buckley, K; Atkins, C G; Chen, D; Schulze, H G; Devine, D V; Blades, M W; Turner, R F B

    2016-03-07

    After being separated from (donated) whole blood, red blood cells are suspended in specially formulated additive solutions and stored (at 4 °C) in polyvinyl chloride (PVC) blood-bags until they are needed for transfusion. With time, the prepared red cell concentrate (RCC) is known to undergo biochemical changes that lower effectiveness of the transfusion, and thus regulations are in place that limit the storage period to 42 days. At present, RCC is not subjected to analytical testing prior to transfusion. In this study, we use Spatially Offset Raman Spectroscopy (SORS) to probe, non-invasively, the biochemistry of RCC inside sealed blood-bags. The retrieved spectra compare well with conventional Raman spectra (of sampled aliquots) and are dominated by features associated with hemoglobin. In addition to the analytical demonstration that SORS can be used to retrieve RCC spectra from standard clinical blood-bags without breaking the sterility of the system, the data reveal interesting detail about the oxygenation-state of the stored cells themselves, namely that some blood-bags unexpectedly contain measurable amounts of deoxygenated hemoglobin after weeks of storage. The demonstration that chemical information can be obtained non-invasively using spectroscopy will enable new studies of RCC degeneration, and points the way to a Raman-based instrument for quality-control in a blood-bank or hospital setting.

  15. Targets and probes for non-invasive imaging of β-cells

    Energy Technology Data Exchange (ETDEWEB)

    Jodal, Andreas; Behe, Martin [Paul Scherrer Institut, Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Villigen (Switzerland); Schibli, Roger [Paul Scherrer Institut, Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Villigen (Switzerland); ETH Zurich, Department of Chemistry and Applied Biosciences, Zurich (Switzerland)

    2017-04-15

    β-cells, located in the islets of the pancreas, are responsible for production and secretion of insulin and play a crucial role in blood sugar regulation. Pathologic β-cells often cause serious medical conditions affecting blood glucose level, which severely impact life quality and are life-threatening if untreated. With 347 million patients, diabetes is one of the most prevalent diseases, and will continue to be one of the largest socioeconomic challenges in the future. The diagnosis still relies mainly on indirect methods like blood sugar measurements. A non-invasive diagnostic imaging modality would allow direct evaluation of β-cell mass and would be a huge step towards personalized medicine. Hyperinsulinism is another serious condition caused by β-cells that excessively secrete insulin, like for instance β-cell hyperplasia and insulinomas. Treatment options with drugs are normally not curative, whereas curative procedures usually consist of the resection of affected regions for which, however, an exact localization of the foci is necessary. In this review, we describe potential tracers under development for targeting β-cells with focus on radiotracers for PET and SPECT imaging, which allow the non-invasive visualization of β-cells. We discuss either the advantages or limitations for the various tracers and modalities. This article concludes with an outlook on future developments and discuss the potential of new imaging probes including dual probes that utilize functionalities for both a radioactive and optical moiety as well as for theranostic applications. (orig.)

  16. Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview

    Directory of Open Access Journals (Sweden)

    Jorge Pereira

    2015-01-01

    Full Text Available Currently, a small number of diseases, particularly cardiovascular (CVDs, oncologic (ODs, neurodegenerative (NDDs, chronic respiratory diseases, as well as diabetes, form a severe burden to most of the countries worldwide. Hence, there is an urgent need for development of efficient diagnostic tools, particularly those enabling reliable detection of diseases, at their early stages, preferably using non-invasive approaches. Breath analysis is a non-invasive approach relying only on the characterisation of volatile composition of the exhaled breath (EB that in turn reflects the volatile composition of the bloodstream and airways and therefore the status and condition of the whole organism metabolism. Advanced sampling procedures (solid-phase and needle traps microextraction coupled with modern analytical technologies (proton transfer reaction mass spectrometry, selected ion flow tube mass spectrometry, ion mobility spectrometry, e-noses, etc. allow the characterisation of EB composition to an unprecedented level. However, a key challenge in EB analysis is the proper statistical analysis and interpretation of the large and heterogeneous datasets obtained from EB research. There is no standard statistical framework/protocol yet available in literature that can be used for EB data analysis towards discovery of biomarkers for use in a typical clinical setup. Nevertheless, EB analysis has immense potential towards development of biomarkers for the early disease diagnosis of diseases.

  17. Non-invasive tissue temperature measurements based on quantitative diffuse optical spectroscopy (DOS) of water

    Energy Technology Data Exchange (ETDEWEB)

    Chung, S H [Department of Physics and Astronomy, University of Pennsylvania, 209 South 33rd Street, Philadelphia, PA 19104 (United States); Cerussi, A E; Tromberg, B J [Beckman Laser Institute and Medical Clinic, University of California, Irvine, 1002 Health Sciences Road, Irvine 92612, CA (United States); Merritt, S I [Masimo Corporation, 40 Parker, Irvine, CA 92618 (United States); Ruth, J, E-mail: bjtrombe@uci.ed [Department of Bioengineering, University of Pennsylvania, 210 S. 33rd Street, Room 240, Skirkanich Hall, Philadelphia, PA 19104 (United States)

    2010-07-07

    We describe the development of a non-invasive method for quantitative tissue temperature measurements using Broadband diffuse optical spectroscopy (DOS). Our approach is based on well-characterized opposing shifts in near-infrared (NIR) water absorption spectra that appear with temperature and macromolecular binding state. Unlike conventional reflectance methods, DOS is used to generate scattering-corrected tissue water absorption spectra. This allows us to separate the macromolecular bound water contribution from the thermally induced spectral shift using the temperature isosbestic point at 996 nm. The method was validated in intralipid tissue phantoms by correlating DOS with thermistor measurements (R = 0.96) with a difference of 1.1 {+-} 0.91 {sup 0}C over a range of 28-48 {sup 0}C. Once validated, thermal and hemodynamic (i.e. oxy- and deoxy-hemoglobin concentration) changes were measured simultaneously and continuously in human subjects (forearm) during mild cold stress. DOS-measured arm temperatures were consistent with previously reported invasive deep tissue temperature studies. These results suggest that DOS can be used for non-invasive, co-registered measurements of absolute temperature and hemoglobin parameters in thick tissues, a potentially important approach for optimizing thermal diagnostics and therapeutics.

  18. Research on the multiple linear regression in non-invasive blood glucose measurement.

    Science.gov (United States)

    Zhu, Jianming; Chen, Zhencheng

    2015-01-01

    A non-invasive blood glucose measurement sensor and the data process algorithm based on the metabolic energy conservation (MEC) method are presented in this paper. The physiological parameters of human fingertip can be measured by various sensing modalities, and blood glucose value can be evaluated with the physiological parameters by the multiple linear regression analysis. Five methods such as enter, remove, forward, backward and stepwise in multiple linear regression were compared, and the backward method had the best performance. The best correlation coefficient was 0.876 with the standard error of the estimate 0.534, and the significance was 0.012 (sig. regression equation was valid. The Clarke error grid analysis was performed to compare the MEC method with the hexokinase method, using 200 data points. The correlation coefficient R was 0.867 and all of the points were located in Zone A and Zone B, which shows the MEC method provides a feasible and valid way for non-invasive blood glucose measurement.

  19. Trojan Horse Strategy for Non-invasive Interference of Clock Gene in the Oyster Crassostrea gigas.

    Science.gov (United States)

    Payton, Laura; Perrigault, Mickael; Bourdineaud, Jean-Paul; Marcel, Anjara; Massabuau, Jean-Charles; Tran, Damien

    2017-08-01

    RNA interference is a powerful method to inhibit specific gene expression. Recently, silencing target genes by feeding has been successfully carried out in nematodes, insects, and small aquatic organisms. A non-invasive feeding-based RNA interference is reported here for the first time in a mollusk bivalve, the pacific oyster Crassostrea gigas. In this Trojan horse strategy, the unicellular alga Heterocapsa triquetra is the food supply used as a vector to feed oysters with Escherichia coli strain HT115 engineered to express the double-stranded RNA targeting gene. To test the efficacy of the method, the Clock gene, a central gene of the circadian clock, was targeted for knockout. Results demonstrated specific and systemic efficiency of the Trojan horse strategy in reducing Clock mRNA abundance. Consequences of Clock disruption were observed in Clock-related genes (Bmal, Tim1, Per, Cry1, Cry2, Rev.-erb, and Ror) and triploid oysters were more sensitive than diploid to the interference. This non-invasive approach shows an involvement of the circadian clock in oyster bioaccumulation of toxins produced by the harmful alga Alexandrium minutum.

  20. Targets and probes for non-invasive imaging of β-cells

    International Nuclear Information System (INIS)

    Jodal, Andreas; Behe, Martin; Schibli, Roger

    2017-01-01

    β-cells, located in the islets of the pancreas, are responsible for production and secretion of insulin and play a crucial role in blood sugar regulation. Pathologic β-cells often cause serious medical conditions affecting blood glucose level, which severely impact life quality and are life-threatening if untreated. With 347 million patients, diabetes is one of the most prevalent diseases, and will continue to be one of the largest socioeconomic challenges in the future. The diagnosis still relies mainly on indirect methods like blood sugar measurements. A non-invasive diagnostic imaging modality would allow direct evaluation of β-cell mass and would be a huge step towards personalized medicine. Hyperinsulinism is another serious condition caused by β-cells that excessively secrete insulin, like for instance β-cell hyperplasia and insulinomas. Treatment options with drugs are normally not curative, whereas curative procedures usually consist of the resection of affected regions for which, however, an exact localization of the foci is necessary. In this review, we describe potential tracers under development for targeting β-cells with focus on radiotracers for PET and SPECT imaging, which allow the non-invasive visualization of β-cells. We discuss either the advantages or limitations for the various tracers and modalities. This article concludes with an outlook on future developments and discuss the potential of new imaging probes including dual probes that utilize functionalities for both a radioactive and optical moiety as well as for theranostic applications. (orig.)

  1. In vivo Microscopic Photoacoustic Spectroscopy for Non-Invasive Glucose Monitoring Invulnerable to Skin Secretion Products.

    Science.gov (United States)

    Sim, Joo Yong; Ahn, Chang-Geun; Jeong, Eun-Ju; Kim, Bong Kyu

    2018-01-18

    Photoacoustic spectroscopy has been shown to be a promising tool for non-invasive blood glucose monitoring. However, the repeatability of such a method is susceptible to changes in skin condition, which is dependent on hand washing and drying due to the high absorption of infrared excitation light to the skin secretion products or water. In this paper, we present a method to meet the challenges of mid-infrared photoacoustic spectroscopy for non-invasive glucose monitoring. By obtaining the microscopic spatial information of skin during the spectroscopy measurement, the skin region where the infrared spectra is insensitive to skin condition can be locally selected, which enables reliable prediction of the blood glucose level from the photoacoustic spectroscopy signals. Our raster-scan imaging showed that the skin condition for in vivo spectroscopic glucose monitoring had significant inhomogeneities and large variability in the probing area where the signal was acquired. However, the selective localization of the probing led to a reduction in the effects of variability due to the skin secretion product. Looking forward, this technology has broader applications not only in continuous glucose monitoring for diabetic patient care, but in forensic science, the diagnosis of malfunctioning sweat pores, and the discrimination of tumors extracted via biopsy.

  2. Deconstructing autofluorescence: non-invasive detection and monitoring of biochemistry in cells and tissues (Conference Presentation)

    Science.gov (United States)

    Goldys, Ewa M.; Gosnell, Martin E.; Anwer, Ayad G.; Cassano, Juan C.; Sue, Carolyn M.; Mahbub, Saabah B.; Pernichery, Sandeep M.; Inglis, David W.; Adhikary, Partho P.; Jazayeri, Jalal A.; Cahill, Michael A.; Saad, Sonia; Pollock, Carol; Sutton-Mcdowall, Melanie L.; Thompson, Jeremy G.

    2016-03-01

    Automated and unbiased methods of non-invasive cell monitoring able to deal with complex biological heterogeneity are fundamentally important for biology and medicine. Label-free cell imaging provides information about endogenous fluorescent metabolites, enzymes and cofactors in cells. However extracting high content information from imaging of native fluorescence has been hitherto impossible. Here, we quantitatively characterise cell populations in different tissue types, live or fixed, by using novel image processing and a simple multispectral upgrade of a wide-field fluorescence microscope. Multispectral intrinsic fluorescence imaging was applied to patient olfactory neurosphere-derived cells, cell model of a human metabolic disease MELAS (mitochondrial myopathy, encephalomyopathy, lactic acidosis, stroke-like syndrome). By using an endogenous source of contrast, subtle metabolic variations have been detected between living cells in their full morphological context which made it possible to distinguish healthy from diseased cells before and after therapy. Cellular maps of native fluorophores, flavins, bound and free NADH and retinoids unveiled subtle metabolic signatures and helped uncover significant cell subpopulations, in particular a subpopulation with compromised mitochondrial function. The versatility of our method is further illustrated by detecting genetic mutations in cancer, non-invasive monitoring of CD90 expression, label-free tracking of stem cell differentiation, identifying stem cell subpopulations with varying functional characteristics, tissue diagnostics in diabetes, and assessing the condition of preimplantation embryos. Our optimal discrimination approach enables statistical hypothesis testing and intuitive visualisations where previously undetectable differences become clearly apparent.

  3. Potential of non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy

    Science.gov (United States)

    Huang, Shaohua; Wang, Lan; Chen, Weisheng; Feng, Shangyuan; Lin, Juqiang; Huang, Zufang; Chen, Guannan; Li, Buhong; Chen, Rong

    2014-11-01

    Non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy (SERS) analysis was presented. Urine SERS spectra were measured on esophagus cancer patients (n = 56) and healthy volunteers (n = 36) for control analysis. Tentative assignments of the urine SERS spectra indicated some interesting esophagus cancer-specific biomolecular changes, including a decrease in the relative content of urea and an increase in the percentage of uric acid in the urine of esophagus cancer patients compared to that of healthy subjects. Principal component analysis (PCA) combined with linear discriminant analysis (LDA) was employed to analyze and differentiate the SERS spectra between normal and esophagus cancer urine. The diagnostic algorithms utilizing a multivariate analysis method achieved a diagnostic sensitivity of 89.3% and specificity of 83.3% for separating esophagus cancer samples from normal urine samples. These results from the explorative work suggested that silver nano particle-based urine SERS analysis coupled with PCA-LDA multivariate analysis has potential for non-invasive detection of esophagus cancer.

  4. Potential of non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy

    International Nuclear Information System (INIS)

    Huang, Shaohua; Wang, Lan; Feng, Shangyuan; Lin, Juqiang; Huang, Zufang; Chen, Guannan; Li, Buhong; Chen, Rong; Chen, Weisheng

    2014-01-01

    Non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy (SERS) analysis was presented. Urine SERS spectra were measured on esophagus cancer patients (n = 56) and healthy volunteers (n = 36) for control analysis. Tentative assignments of the urine SERS spectra indicated some interesting esophagus cancer-specific biomolecular changes, including a decrease in the relative content of urea and an increase in the percentage of uric acid in the urine of esophagus cancer patients compared to that of healthy subjects. Principal component analysis (PCA) combined with linear discriminant analysis (LDA) was employed to analyze and differentiate the SERS spectra between normal and esophagus cancer urine. The diagnostic algorithms utilizing a multivariate analysis method achieved a diagnostic sensitivity of 89.3% and specificity of 83.3% for separating esophagus cancer samples from normal urine samples. These results from the explorative work suggested that silver nano particle-based urine SERS analysis coupled with PCA–LDA multivariate analysis has potential for non-invasive detection of esophagus cancer. (letter)

  5. Clinical Validation of Non-Invasive Cardiac Output Monitoring in Healthy Pregnant Women.

    Science.gov (United States)

    McLaughlin, Kelsey; Wright, Stephen P; Kingdom, John C P; Parker, John D

    2017-11-01

    Non-invasive hemodynamic monitoring has the potential to be a valuable clinical tool for the screening and management of hypertensive disorders of pregnancy. The objective of this study was to validate the clinical utility of the non-invasive cardiac output monitoring (NICOM) system in pregnant women. Twenty healthy pregnant women with a singleton pregnancy at 22 to 26 weeks' gestation were enrolled in this study. Measures of heart rate, stroke volume, and cardiac output were obtained through NICOM and compared with Doppler echocardiography. NICOM significantly overestimated measures of both stroke volume and cardiac output compared with Doppler echocardiography (95 ± 4 vs. 73 ± 4 mL, P gold standard for the measurement of cardiac output in the setting of pregnancy. However, once normal values have been established, NICOM has the potential to be a useful clinical tool for monitoring maternal hemodynamics in pregnant women. Further investigation regarding the validity of NICOM is required in larger populations of healthy and hypertensive pregnant women to determine whether this device is appropriate for maternal hemodynamic assessment during pregnancy. Copyright © 2017 The Society of Obstetricians and Gynaecologists of Canada/La Société des obstétriciens et gynécologues du Canada. Published by Elsevier Inc. All rights reserved.

  6. Non-invasive estimation of intracranial pressure. MR-based evaluation in children with hydrocephalus

    International Nuclear Information System (INIS)

    Muehlmann, M.; Steffinger, D.; Ertl-Wagner, B.; Koerte, I.K.; Peraud, A.; Lehner, M.; Heinen, F.; Alperin, N.

    2012-01-01

    The intracranial pressure (ICP) is a crucially important parameter for diagnostic and therapeutic decision-making in patients with hydrocephalus. So far there is no standard method to non-invasively assess the ICP. Various approaches to obtain the ICP semi-invasively or non-invasively are discussed and the clinical application of a magnetic resonance imaging (MRI)-based method to estimate ICP (MR-ICP) is demonstrated in a group of pediatric patients with hydrocephalus. Arterial inflow, venous drainage and craniospinal cerebrospinal fluid (CSF) flow were quantified using phase-contrast imaging to derive the MR-ICP. A total of 15 patients with hydrocephalus (n=9 treated with shunt placement or ventriculostomy) underwent MRI on a 3 T scanner applying retrospectively-gated cine phase contrast sequences. Of the patients six had clinical symptoms indicating increased ICP (age 2.5-14.61 years, mean 7.4 years) and nine patients had no clinical signs of elevated ICP (age 2.1-15.9 years; mean 9.8 years; all treated with shunt or ventriculostomy). Median MR-ICP in symptomatic patients was 24.5 mmHg (25th percentile 20.4 mmHg; 75th percentile 44.6 mmHg). Median MR-ICP in patients without acute signs of increased ICP was 9.8 mmHg (25th percentile 8.6 mmHg; 75th percentile 11.4 mmHg). Group differences were significant (p [de

  7. Reactivity of dogs' brain oscillations to visual stimuli measured with non-invasive electroencephalography.

    Directory of Open Access Journals (Sweden)

    Miiamaaria V Kujala

    Full Text Available Studying cognition of domestic dogs has gone through a renaissance within the last decades. However, although the behavioral studies of dogs are beginning to be common in the field of animal cognition, the neural events underlying cognition remain unknown. Here, we employed a non-invasive electroencephalography, with adhesive electrodes attached to the top of the skin, to measure brain activity of from 8 domestic dogs (Canis familiaris while they stayed still to observe photos of dog and human faces. Spontaneous oscillatory activity of the dogs, peaking in the sensors over the parieto-occipital cortex, was suppressed statistically significantly during visual task compared with resting activity at the frequency of 15-30 Hz. Moreover, a stimulus-induced low-frequency (~2-6 Hz suppression locked to the stimulus onset was evident at the frontal sensors, possibly reflecting a motor rhythm guiding the exploratory eye movements. The results suggest task-related reactivity of the macroscopic oscillatory activity in the dog brain. To our knowledge, the study is the first to reveal non-invasively measured reactivity of brain electrophysiological oscillations in healthy dogs, and it has been based purely on positive operant conditional training, without the need for movement restriction or medication.

  8. Non-invasive brain stimulation for Parkinson's disease: Current concepts and outlook 2015.

    Science.gov (United States)

    Benninger, David H; Hallett, Mark

    2015-01-01

    In advanced Parkinson's disease (PD), the emergence of symptoms refractory to conventional therapy poses a therapeutic challenge. The success of deep brain stimulation (DBS) and advances in the understanding of the pathophysiology of PD have raised interest in non-invasive brain stimulation as an alternative therapeutic tool. The rationale for its use draws from the concept that reversing abnormalities in brain activity and physiology thought to cause the clinical deficits may restore normal functioning. Currently the best evidence in support of this concept comes from DBS, which improves motor deficits, and modulates brain activity and motor cortex physiology, though whether a causal interaction exists remains largely undetermined. Most trials of non-invasive brain stimulation in PD have applied repetitive transcranial magnetic stimulation (rTMS) targeting the primary motor cortex and cortical areas of the motor circuit. Published studies suggest a possible therapeutic potential of rTMS and transcranial direct current stimulation (tDCS), but clinical effects so far have been small and negligible regarding functional independence and quality of life. Approaches to potentiate the efficacy of rTMS, including increasing stimulation intensity and novel stimulation parameters, derive their rationale from studies of brain physiology. These novel parameters simulate normal firing patterns or act on the hypothesized role of oscillatory activity in the motor cortex and basal ganglia in motor control. There may also be diagnostic potential of TMS in characterizing individual traits for personalized medicine.

  9. Non-invasive ventilation with neurally adjusted ventilatory assist in newborns.

    Science.gov (United States)

    Stein, Howard; Beck, Jennifer; Dunn, Michael

    2016-06-01

    Neurally adjusted ventilatory assist (NAVA) is a mode of ventilation in which both the timing and degree of ventilatory assist are controlled by the patient. Since NAVA uses the diaphragm electrical activity (Edi) as the controller signal, it is possible to deliver synchronized non-invasive NAVA (NIV-NAVA) regardless of leaks and to monitor continuously patient respiratory pattern and drive. Advantages of NIV-NAVA over conventional modes include improved patient-ventilator interaction, reliable respiratory monitoring and self-regulation of respiratory support. In theory, these characteristics make NIV-NAVA an ideal mode to provide effective, appropriate non-invasive support to newborns with respiratory insufficiency. NIV-NAVA has been successfully used clinically in neonates as a mode of ventilation to prevent intubation, to allow early extubation, and as a novel way to deliver nasal continuous positive airway pressure. The use of NAVA in neonates is described with an emphasis on studies and clinical experience with NIV-NAVA. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Clinical, social and ethical issues associated with non-invasive prenatal testing for aneuploidy.

    Science.gov (United States)

    Griffin, Blanche; Edwards, Samantha; Chitty, Lyn S; Lewis, Celine

    2018-03-01

    Non-invasive prenatal testing (NIPT), based on analysis of cell-free foetal DNA, is rapidly becoming a preferred method to screen for chromosomal aneuploidy with the technology now available in over 90 countries. This review provides an up-to-date discussion of the key clinical, social and ethical implications associated with this revolutionary technology. Stakeholders are positive about a test that is highly accurate, safe, can be perfomed early in pregnancy, identifies affected pregnancies that might otherwise have been missed and reduces the need for invasive testing. Nevertheless, professional societies currently recommend it as an advanced screening test due to the low false positive rate (FPR). Despite the practical and psychological benefits, a number of concerns have been raised which warrant attention. These include the potential for routinisation of testing and subsequent impact on informed decision-making, an "easy" blood test inadvertently contributing to women feeling pressured to take the test, fears NIPT will lead to less tolerance and support for those living with Down syndrome and the heightened expectation of having "perfect babies". These issues can be addressed to some extent through clinician education, patient information and establishing national and international consensus in the development of comprehensive and regularly updated guidelines. As the number of conditions we are able to test for non-invasively expands it will be increasingly important to ensure pre-test counselling can be delivered effectively supported by knowledgeable healthcare professionals.

  11. A review of invasive and non-invasive sensory feedback in upper limb prostheses.

    Science.gov (United States)

    Svensson, Pamela; Wijk, Ulrika; Björkman, Anders; Antfolk, Christian

    2017-06-01

    The constant challenge to restore sensory feedback in prosthetic hands has provided several research solutions, but virtually none has reached clinical fruition. A prosthetic hand with sensory feedback that closely imitates an intact hand and provides a natural feeling may induce the prosthetic hand to be included in the body image and also reinforces the control of the prosthesis. Areas covered: This review presents non-invasive sensory feedback systems such as mechanotactile, vibrotactile, electrotactile and combinational systems which combine the modalities; multi-haptic feedback. Invasive sensory feedback has been tried less, because of the inherent risk, but it has successfully shown to restore some afferent channels. In this review, invasive methods are also discussed, both extraneural and intraneural electrodes, such as cuff electrodes and transverse intrafascicular multichannel electrodes. The focus of the review is on non-invasive methods of providing sensory feedback to upper-limb amputees. Expert commentary: Invoking embodiment has shown to be of importance for the control of prosthesis and acceptance by the prosthetic wearers. It is a challenge to provide conscious feedback to cover the lost sensibility of a hand, not be overwhelming and confusing for the user, and to integrate technology within the constraint of a wearable prosthesis.

  12. Studies of X-ray tube aging by non-invasive methods

    International Nuclear Information System (INIS)

    Bottaro, Marcio.

    2007-01-01

    The objective of the present work was the evaluation of an x ray tube aging with an anode made of tungsten, used in radio diagnostic. Workloads were applied, in accordance with Brazilian workload distribution, and periodic measurements of quantities related to the radiation quality of the beam were performed. For the purpose of this work, a single phase, full bridge clinical system was employed. For the long term x ray tube characteristics evaluation related to the applied workload, it was necessary to measure parameters that could quantitatively represent the tube aging, with special attention to the anode roughening. For the indirect measurement of tube aging, four parameters were chosen, some of them normally applied in x ray diagnostic quality control: first and second half value layers (HVL), focal spot dimensions, non invasive measurement of Practical Peak Voltage (PPV) and x ray spectroscopy. These parameters were measured before any workload and after each workload intervals. To assure confidence of the results reproducibility conditions were stated to each evaluated parameter. The uncertainties involved in all measurement processes were calculated to evaluate the real contributions of x ray tube aging effects on non invasive parameters. Within all evaluated parameters, the most sensitive to long term workload were the mean energy obtained from spectroscopy and half value layers. A model related to these parameters was applied and estimates of x ray tube aging rate for different acceleration voltages and anodic currents were calculated. (author)

  13. Urinary Cell-Free DNA Quantification as Non-Invasive Biomarker in Patients with Bladder Cancer.

    Science.gov (United States)

    Brisuda, Antonin; Pazourkova, Eva; Soukup, Viktor; Horinek, Ales; Hrbáček, Jan; Capoun, Otakar; Svobodova, Iveta; Pospisilova, Sarka; Korabecna, Marie; Mares, Jaroslav; Hanuš, Tomáš; Babjuk, Marek

    2016-01-01

    Concentration of urinary cell-free DNA (ucfDNA) belongs to potential bladder cancer markers, but the reported results are inconsistent due to the use of various non-standardised methodologies. The aim of the study was to standardise the methodology for ucfDNA quantification as a potential non-invasive tumour biomarker. In total, 66 patients and 34 controls were enrolled into the study. Volumes of each urine portion (V) were recorded and ucfDNA concentrations (c) were measured using real-time PCR. Total amounts (TA) of ucfDNA were calculated and compared between patients and controls. Diagnostic accuracy of the TA of ucfDNA was determined. The calculation of TA of ucfDNA in the second urine portion was the most appropriate approach to ucfDNA quantification, as there was logarithmic dependence between the volume and the concentration of a urine portion (p = 0.0001). Using this methodology, we were able to discriminate between bladder cancer patients and subjects without bladder tumours (p = 0.0002) with area under the ROC curve of 0.725. Positive and negative predictive value of the test was 90 and 45%, respectively. Quantification of ucf DNA according to our modified method could provide a potential non-invasive biomarker for diagnosis of patients with bladder cancer. © 2015 S. Karger AG, Basel.

  14. Breath analysis as a potential and non-invasive frontier in disease diagnosis: an overview.

    Science.gov (United States)

    Pereira, Jorge; Porto-Figueira, Priscilla; Cavaco, Carina; Taunk, Khushman; Rapole, Srikanth; Dhakne, Rahul; Nagarajaram, Hampapathalu; Câmara, José S

    2015-01-09

    Currently, a small number of diseases, particularly cardiovascular (CVDs), oncologic (ODs), neurodegenerative (NDDs), chronic respiratory diseases, as well as diabetes, form a severe burden to most of the countries worldwide. Hence, there is an urgent need for development of efficient diagnostic tools, particularly those enabling reliable detection of diseases, at their early stages, preferably using non-invasive approaches. Breath analysis is a non-invasive approach relying only on the characterisation of volatile composition of the exhaled breath (EB) that in turn reflects the volatile composition of the bloodstream and airways and therefore the status and condition of the whole organism metabolism. Advanced sampling procedures (solid-phase and needle traps microextraction) coupled with modern analytical technologies (proton transfer reaction mass spectrometry, selected ion flow tube mass spectrometry, ion mobility spectrometry, e-noses, etc.) allow the characterisation of EB composition to an unprecedented level. However, a key challenge in EB analysis is the proper statistical analysis and interpretation of the large and heterogeneous datasets obtained from EB research. There is no standard statistical framework/protocol yet available in literature that can be used for EB data analysis towards discovery of biomarkers for use in a typical clinical setup. Nevertheless, EB analysis has immense potential towards development of biomarkers for the early disease diagnosis of diseases.

  15. Anaphylaxis Imaging: Non-Invasive Measurement of Surface Body Temperature and Physical Activity in Small Animals.

    Directory of Open Access Journals (Sweden)

    Krisztina Manzano-Szalai

    Full Text Available In highly sensitized patients, the encounter with a specific allergen from food, insect stings or medications may rapidly induce systemic anaphylaxis with potentially lethal symptoms. Countless animal models of anaphylaxis, most often in BALB/c mice, were established to understand the pathophysiology and to prove the safety of different treatments. The most common symptoms during anaphylactic shock are drop of body temperature and reduced physical activity. To refine, improve and objectify the currently applied manual monitoring methods, we developed an imaging method for the automated, non-invasive measurement of the whole-body surface temperature and, at the same time, of the horizontal and vertical movement activity of small animals. We tested the anaphylaxis imaging in three in vivo allergy mouse models for i milk allergy, ii peanut allergy and iii egg allergy. These proof-of-principle experiments suggest that the imaging technology represents a reliable non-invasive method for the objective monitoring of small animals during anaphylaxis over time. We propose that the method will be useful for monitoring diseases associated with both, changes in body temperature and in physical behaviour.

  16. Non-Invasive Electromagnetic Skin Patch Sensor to Measure Intracranial Fluid–Volume Shifts

    Directory of Open Access Journals (Sweden)

    Jacob Griffith

    2018-03-01

    Full Text Available Elevated intracranial fluid volume can drive intracranial pressure increases, which can potentially result in numerous neurological complications or death. This study’s focus was to develop a passive skin patch sensor for the head that would non-invasively measure cranial fluid volume shifts. The sensor consists of a single baseline component configured into a rectangular planar spiral with a self-resonant frequency response when impinged upon by external radio frequency sweeps. Fluid volume changes (10 mL increments were detected through cranial bone using the sensor on a dry human skull model. Preliminary human tests utilized two sensors to determine feasibility of detecting fluid volume shifts in the complex environment of the human body. The correlation between fluid volume changes and shifts in the first resonance frequency using the dry human skull was classified as a second order polynomial with R2 = 0.97. During preliminary and secondary human tests, a ≈24 MHz and an average of ≈45.07 MHz shifts in the principal resonant frequency were measured respectively, corresponding to the induced cephalad bio-fluid shifts. This electromagnetic resonant sensor may provide a non-invasive method to monitor shifts in fluid volume and assist with medical scenarios including stroke, cerebral hemorrhage, concussion, or monitoring intracranial pressure.

  17. Exhaled breath condensate pH and hydrogen peroxide as non-invasive markers for asthma

    International Nuclear Information System (INIS)

    Al-Obaidy, Amina H.; Al-Samarai, Abdul-Gahni M.

    2007-01-01

    Objective was to estimate the predictive value of exhaled breath condensate (EBC) hydrogen peroxide (H2O2) concentration and pH as non-invasive markers in asthma. Fifty patients with unstable, steroid naive atopic asthma were included in this study, 25 with persistent asthma. Asthma diagnosis was according to the National Heart Lung and Blood Institute guidelines for the diagnosis and management of asthma. Forced expiratory volume in one second (FEV1) was measured by computerized spirometry. The EBC H2O2 assay was carried out using the colorimetric assay. The study was conducted from January to December 2005 in the Asthma and Allergy Center, Tikrit, Iraq. The EBC H2O2 concentration was higher in the asthmatic group (0.91mol) as compared with the control (0.23 mol). There was inverse correlation between EBC H2O2 concentration and FEV1 predicted percent for asthmatic patients. The mean EBC pH was lower in the asthmatic than the control group. There was a positive correlation between EBC pH and FEV 1 predicted percent for asthmatic patients. There was an inverse correlation between EBC H2O2 concentration and pH for all asthmatic patients, intermittent, and persistent asthmatic group. Exhaled breath condensate hydrogen peroxide concentration and pH was a good non-invasive marker for asthma, whether it was with a persistent or intermittent course. (author)

  18. Invasive clonal plant species have a greater root-foraging plasticity than non-invasive ones.

    Science.gov (United States)

    Keser, Lidewij H; Dawson, Wayne; Song, Yao-Bin; Yu, Fei-Hai; Fischer, Markus; Dong, Ming; van Kleunen, Mark

    2014-03-01

    Clonality is frequently positively correlated with plant invasiveness, but which aspects of clonality make some clonal species more invasive than others is not known. Due to their spreading growth form, clonal plants are likely to experience spatial heterogeneity in nutrient availability. Plasticity in allocation of biomass to clonal growth organs and roots may allow these plants to forage for high-nutrient patches. We investigated whether this foraging response is stronger in species that have become invasive than in species that have not. We used six confamilial pairs of native European clonal plant species differing in invasion success in the USA. We grew all species in large pots under homogeneous or heterogeneous nutrient conditions in a greenhouse, and compared their nutrient-foraging response and performance. Neither invasive nor non-invasive species showed significant foraging responses to heterogeneity in clonal growth organ biomass or in aboveground biomass of clonal offspring. Invasive species had, however, a greater positive foraging response in terms of root and belowground biomass than non-invasive species. Invasive species also produced more total biomass. Our results suggest that the ability for strong root foraging is among the characteristics promoting invasiveness in clonal plants.

  19. Simulation based investigation of source-detector configurations for non-invasive fetal pulse oximetry

    Directory of Open Access Journals (Sweden)

    Böttrich Marcel

    2015-09-01

    Full Text Available Transabdominal fetal pulse oximetry is a method to monitor the oxygen supply of the unborn child non-invasively. Due to the measurement setup, the received signal of the detector is composed of photons coding purely maternal and photons coding mixed fetal-maternal information. To analyze the wellbeing of the fetus, the fetal signal is extracted from the mixed component. In this paper we assess source-detector configurations, such that the mixed fetal-maternal components of the acquired signals are maximized. Monte-Carlo method is used to simulate light propagation and photon distribution in tissue. We use a plane layer and a spherical layer geometry to model the abdomen of a pregnant woman. From the simulations we extracted the fluence at the detector side for several source-detector distances and analyzed the ratio of the mixed fluence component to total fluence. Our simulations showed that the power of the mixed component depends on the source-detector distance as expected. Further we were able to visualize hot spot areas in the spherical layer model where the mixed fluence ratio reaches the highest level. The results are of high importance for sensor design considering signal composition and quality for non-invasive fetal pulse oximetry.

  20. Non-invasive quantitative pulmonary V/Q imaging using Fourier decomposition MRI at 1.5T

    Energy Technology Data Exchange (ETDEWEB)

    Kjoerstad, Aasmund; Corteville, Dominique M.R.; Zoellner, Frank G.; Schad, Lothar R. [Heidelberg Univ., Medical Faculty Mannheim (Germany). Computer Assisted Clinical Medicine; Henzler, Thomas [Heidelberg Univ., Medical Faculty Mannheim (Germany). Inst. of Clinical Radiology and Nuclear Medicine; Schmid-Bindert, Gerald [Heidelberg Univ., Medical Faculty Mannheim (Germany). Interdisciplinary Thoracic Oncology

    2015-07-01

    Techniques for quantitative pulmonary perfusion and ventilation using the Fourier Decomposition method were recently demonstrated. We combine these two techniques and show that ventilation-perfusion (V/Q) imaging is possible using only a single MR acquisition of less than thirty seconds. The Fourier Decomposition method is used in combination with two quantification techniques, which extract baselines from within the images themselves and thus allows quantification. For the perfusion, a region assumed to consist of 100% blood is utilized, while for the ventilation the zero-frequency component is used. V/Q-imaging is then done by dividing the quantified ventilation map with the quantified perfusion map. The techniques were used on ten healthy volunteers and fifteen patients diagnosed with lung cancer. A mean V/Q-ratio of 1.15±0.22 was found for the healthy volunteers and a mean V/Q-ratio of 1.93±0.83 for the non-afflicted lung in the patients. Mean V/Q-ratio in the afflicted (tumor-bearing) lung was found to be 1.61±1.06. Functional defects were clearly visible in many of the patient images, but 5 of 15 patient images had to be excluded due to artifacts or low SNR, indicating a lack of robustness. Conclusion Non-invasive, quantitative V/Q-imaging is possible using Fourier Decomposition MRI. The method requires only a single acquisition of less than 30 seconds, but robustness in patients remains an issue.

  1. Non-invasive quantitative pulmonary V/Q imaging using Fourier decomposition MRI at 1.5T.

    Science.gov (United States)

    Kjørstad, Åsmund; Corteville, Dominique M R; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2015-12-01

    Techniques for quantitative pulmonary perfusion and ventilation using the Fourier Decomposition method were recently demonstrated. We combine these two techniques and show that ventilation-perfusion (V/Q) imaging is possible using only a single MR acquisition of less than thirty seconds. The Fourier Decomposition method is used in combination with two quantification techniques, which extract baselines from within the images themselves and thus allows quantification. For the perfusion, a region assumed to consist of 100% blood is utilized, while for the ventilation the zero-frequency component is used. V/Q-imaging is then done by dividing the quantified ventilation map with the quantified perfusion map. The techniques were used on ten healthy volunteers and fifteen patients diagnosed with lung cancer. A mean V/Q-ratio of 1.15 ± 0.22 was found for the healthy volunteers and a mean V/Q-ratio of 1.93 ± 0.83 for the non-afflicted lung in the patients. Mean V/Q-ratio in the afflicted (tumor-bearing) lung was found to be 1.61 ± 1.06. Functional defects were clearly visible in many of the patient images, but 5 of 15 patient images had to be excluded due to artifacts or low SNR, indicating a lack of robustness. Non-invasive, quantitative V/Q-imaging is possible using Fourier Decomposition MRI. The method requires only a single acquisition of less than 30 seconds, but robustness in patients remains an issue. Copyright © 2015. Published by Elsevier GmbH.

  2. Recent developments in human biomonitoring: non-invasive assessment of target tissue dose and effects of pneumotoxic metals.

    Science.gov (United States)

    Mutti, A; Corradi, M

    2006-01-01

    Tobacco smoke and polluted environments substantially increase the lung burden of pneumotoxic chemicals, particularly pneumotoxic metallic elements. To achieve a better understanding of the early events between exposure to inhaled toxicants and the onset of adverse effects on the lung, the characterization of dose at the target organ would be extremely useful. Exhaled breath condensate (EBC), obtained by cooling exhaled air under conditions of spontaneous breathing, is a novel technique that could provide a non-invasive assessment of pulmonary pathobiology. Considering that EBC is water practically free of interfering solutes, it represents an ideal biological matrix for elemental characterization. Published data show that several toxic metals and trace elements are detectable in EBC, raising the possibility of using this medium to quantify the lung tissue dose of pneumotoxic substances. This novel approach may represent a significant advance over the analysis of alternative media (blood, serum, urine, hair), which are not as reliable (owing to interfering substances in the complex matrix) and reflect systemic rather than lung (target tissue) levels of both toxic metals and essential trace elements. Data obtained among workers occupationally exposed to either hard metals or chromium (VI) and in smokers with or without chronic obstructive pulmonary disease (COPD) are reviewed to show that--together with biomarkers of exposure--EBC also allows the simultaneous quantification of biomarkers of effect directly sampled from the epithelial lining fluid, thus providing novel insights on both kinetic and dynamic aspects of metal toxicology.

  3. Non-invasive method for selection of electrodes and stimulus parameters for FES applications with intrafascicular arrays

    Science.gov (United States)

    Dowden, B. R.; Frankel, M. A.; Normann, R. A.; Clark, G. A.

    2012-02-01

    High-channel-count intrafascicular electrode arrays provide comprehensive and selective access to the peripheral nervous system. One practical difficulty in using several electrode arrays to evoke coordinated movements in paralyzed limbs is the identification of the appropriate stimulation channels and stimulus parameters to evoke desired movements. Here we present the use of a six degree-of-freedom load cell placed under the foot of a feline to characterize the muscle activation produced by three 100-electrode Utah Slanted Electrode Arrays (USEAs) implanted into the femoral nerves, sciatic nerves, and muscular branches of the sciatic nerves of three cats. Intramuscular stimulation was used to identify the endpoint force directions produced by 15 muscles of the hind limb, and these directions were used to classify the forces produced by each intrafascicular USEA electrode as flexion or extension. For 451 USEA electrodes, stimulus intensities for threshold and saturation muscle forces were identified, and the 3D direction and linearity of the force recruitment curves were determined. Further, motor unit excitation independence for 198 electrode pairs was measured using the refractory technique. This study demonstrates the utility of 3D endpoint force monitoring as a simple and non-invasive metric for characterizing the muscle-activation properties of hundreds of implanted peripheral nerve electrodes, allowing for electrode and parameter selection for neuroprosthetic applications.

  4. Feasibility study of the non-invasive estimation of the β+ arterial input function for human PET imaging

    International Nuclear Information System (INIS)

    Hubert, X.

    2009-12-01

    This work deals with the estimation of the concentration of molecules in arterial blood which are labelled with positron-emitting radioelements. This concentration is called 'β + arterial input function'. This concentration has to be estimated for a large number of pharmacokinetic analyses. Nowadays it is measured through series of arterial sampling, which is an accurate method but requiring a stringent protocol. Complications might occur during arterial blood sampling because this method is invasive (hematomas, nosocomial infections). The objective of this work is to overcome this risk through a non-invasive estimation of β + input function with an external detector and a collimator. This allows the reconstruction of blood vessels and thus the discrimination of arterial signal from signals in other tissues. Collimators in medical imaging are not adapted to estimate β + input function because their sensitivity is very low. During this work, they are replaced by coded-aperture collimators, originally developed for astronomy. New methods where coded apertures are used with statistical reconstruction algorithms are presented. Techniques for analytical ray-tracing and for the acceleration of reconstructions are proposed. A new method which decomposes reconstructions on temporal sets and on spatial sets is also developed to efficiently estimate arterial input function from series of temporal acquisitions. This work demonstrates that the trade-off between sensitivity and spatial resolution in PET can be improved thanks to coded aperture collimators and statistical reconstruction algorithm; it also provides new tools to implement such improvements. (author)

  5. Non-invasive evaluation of liver stiffness after splenectomy in rabbits with CCl4-induced liver fibrosis.

    Science.gov (United States)

    Wang, Ming-Jun; Ling, Wen-Wu; Wang, Hong; Meng, Ling-Wei; Cai, He; Peng, Bing

    2016-12-14

    To investigate the diagnostic performance of liver stiffness measurement (LSM) by elastography point quantification (ElastPQ) in animal models and determine the longitudinal changes in liver stiffness by ElastPQ after splenectomy at different stages of fibrosis. Liver stiffness was measured in sixty-eight rabbits with CCl 4 -induced liver fibrosis at different stages and eight healthy control rabbits by ElastPQ. Liver biopsies and blood samples were obtained at scheduled time points to assess liver function and degree of fibrosis. Thirty-one rabbits with complete data that underwent splenectomy at different stages of liver fibrosis were then included for dynamic monitoring of changes in liver stiffness by ElastPQ and liver function according to blood tests. LSM by ElastPQ was significantly correlated with histologic fibrosis stage ( r = 0.85, P fibrosis, moderate fibrosis, and cirrhosis, respectively. Longitudinal monitoring of the changes in liver stiffness by ElastPQ showed that early splenectomy (especially F1) may delay liver fibrosis progression. ElastPQ is an available, convenient, objective and non-invasive technique for assessing liver stiffness in rabbits with CCl 4 -induced liver fibrosis. In addition, liver stiffness measurements using ElastPQ can dynamically monitor the changes in liver stiffness in rabbit models, and in patients, after splenectomy.

  6. Non-invasive monitoring of cytokine-based regenerative treatment of cartilage by hyperspectral unmixing (Conference Presentation)

    Science.gov (United States)

    Mahbub, Saabah B.; Succer, Peter; Gosnell, Martin E.; Anwaer, Ayad G.; Herbert, Benjamin; Vesey, Graham; Goldys, Ewa M.

    2016-03-01

    Extracting biochemical information from tissue autofluorescence is a promising approach to non-invasively monitor disease treatments at a cellular level, without using any external biomarkers. Our recently developed unsupervised hyperspectral unmixing by Dependent Component Analysis (DECA) provides robust and detailed metabolic information with proper account of intrinsic cellular heterogeneity. Moreover this method is compatible with established methods of fluorescent biomarker labelling. Recently adipose-derived stem cell (ADSC) - based therapies have been introduced for treating different diseases in animals and humans. ADSC have been shown promise in regenerative treatments for osteoarthritis and other bone and joint disorders. One of the mechanism of their action is their anti-inflammatory effects within osteoarthritic joints which aid the regeneration of cartilage. These therapeutic effects are known to be driven by secretions of different cytokines from the ADSCs. We have been using the hyperspectral unmixing techniques to study in-vitro the effects of ADSC-derived cytokine-rich secretions with the cartilage chip in both human and bovine samples. The study of metabolic effects of different cytokine treatment on different cartilage layers makes it possible to compare the merits of those treatments for repairing cartilage.

  7. Label-free SPR detection of gluten peptides in urine for non-invasive celiac disease follow-up.

    Science.gov (United States)

    Soler, Maria; Estevez, M-Carmen; Moreno, Maria de Lourdes; Cebolla, Angel; Lechuga, Laura M

    2016-05-15

    Motivated by the necessity of new and efficient methods for dietary gluten control of celiac patients, we have developed a simple and highly sensitive SPR biosensor for the detection of gluten peptides in urine. The sensing methodology enables rapid and label-free quantification of the gluten immunogenic peptides (GIP) by using G12 mAb. The overall performance of the biosensor has been in-depth optimized and evaluated in terms of sensitivity, selectivity and reproducibility, reaching a limit of detection of 0.33 ng mL(-1). Besides, the robustness and stability of the methodology permit the continuous use of the biosensor for more than 100 cycles with excellent repeatability. Special efforts have been focused on preventing and minimizing possible interferences coming from urine matrix enabling a direct analysis in this fluid without requiring extraction or purification procedures. Our SPR biosensor has proven to detect and identify gluten consumption by evaluating urine samples from healthy and celiac individuals with different dietary gluten conditions. This novel biosensor methodology represents a novel approach to quantify the digested gluten peptides in human urine with outstanding sensitivity in a rapid and non-invasive manner. Our technique should be considered as a promising opportunity to develop Point-of-Care (POC) devices for an efficient, simple and accurate gluten free diet (GFD) monitoring as well as therapy follow-up of celiac disease patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. The characterization of natural gemstones using non-invasive FT-IR spectroscopy: New data on tourmalines.

    Science.gov (United States)

    Mercurio, Mariano; Rossi, Manuela; Izzo, Francesco; Cappelletti, Piergiulio; Germinario, Chiara; Grifa, Celestino; Petrelli, Maurizio; Vergara, Alessandro; Langella, Alessio

    2018-02-01

    Fourteen samples of tourmaline from the Real Museo Mineralogico of Federico II University (Naples) have been characterized through multi-methodological investigations (EMPA-WDS, SEM-EDS, LA-ICP-MS, and FT-IR spectroscopy). The samples show different size, morphology and color, and are often associated with other minerals. Data on major and minor elements allowed to identify and classify tourmalines as follows: elbaites, tsilaisite, schorl, dravites, uvites and rossmanite. Non-invasive, non-destructive FT-IR and in-situ analyses were carried out on the same samples to validate this chemically-based identification and classification. The results of this research show that a complete characterization of this mineral species, usually time-consuming and expensive, can be successfully achieved through non-destructive FT-IR technique, thus representing a reliable tool for a fast classification extremely useful to plan further analytical strategies, as well as to support gemological appraisals. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Non-invasive vibrational SFG spectroscopy reveals that bacterial adhesion can alter the conformation of grafted "brush" chains on SAM.

    Science.gov (United States)

    Bulard, Emilie; Guo, Ziang; Zheng, Wanquan; Dubost, Henri; Fontaine-Aupart, Marie-Pierre; Bellon-Fontaine, Marie-Noëlle; Herry, Jean-Marie; Briandet, Romain; Bourguignon, Bernard

    2011-04-19

    Understanding bacterial adhesion on a surface is a crucial step to design new materials with improved properties or to control biofilm formation and eradication. Sum Frequency Generation (SFG) vibrational spectroscopy has been employed to study in situ the conformational response of a self-assembled monolayer (SAM) of octadecanethiol (ODT) on a gold film to the adhesion of hydrophilic and hydrophobic ovococcoid model bacteria. The present work highlights vibrational SFG spectroscopy as a powerful and unique non-invasive biophysical technique to probe and control bacteria interaction with ordered surfaces. Indeed, the SFG vibrational spectral changes reveal different ODT SAM conformations in air and upon exposure to aqueous solution or bacterial adhesion. Furthermore, this effect depends on the bacterial cell surface properties. The SFG spectral modeling demonstrates that hydrophobic bacteria flatten the ODT SAM alkyl chain terminal part, whereas the hydrophilic ones raise this ODT SAM terminal part. Microorganism-induced alteration of grafted chains can thus affect the desired interfacial functionality, a result that should be considered for the design of new reactive materials. © 2011 American Chemical Society

  10. Non-invasive optical estimate of tissue composition to differentiate malignant from benign breast lesions: A pilot study

    Science.gov (United States)

    Taroni, Paola; Paganoni, Anna Maria; Ieva, Francesca; Pifferi, Antonio; Quarto, Giovanna; Abbate, Francesca; Cassano, Enrico; Cubeddu, Rinaldo

    2017-01-01

    Several techniques are being investigated as a complement to screening mammography, to reduce its false-positive rate, but results are still insufficient to draw conclusions. This initial study explores time domain diffuse optical imaging as an adjunct method to classify non-invasively malignant vs benign breast lesions. We estimated differences in tissue composition (oxy- and deoxyhemoglobin, lipid, water, collagen) and absorption properties between lesion and average healthy tissue in the same breast applying a perturbative approach to optical images collected at 7 red-near infrared wavelengths (635-1060 nm) from subjects bearing breast lesions. The Discrete AdaBoost procedure, a machine-learning algorithm, was then exploited to classify lesions based on optically derived information (either tissue composition or absorption) and risk factors obtained from patient’s anamnesis (age, body mass index, familiarity, parity, use of oral contraceptives, and use of Tamoxifen). Collagen content, in particular, turned out to be the most important parameter for discrimination. Based on the initial results of this study the proposed method deserves further investigation.

  11. The penile cuff test: A clinically useful non-invasive urodynamic investigation to diagnose men with lower urinary tract symptoms

    Directory of Open Access Journals (Sweden)

    Christopher Harding

    2009-01-01

    Full Text Available Objectives: To summarize the development of a novel non-invasive test to categorize voiding dysfunction in men complaining of lower urinary tract symptoms (LUTS - the penile cuff test. Methods: The test involves the controlled inflation of a penile cuff during micturition to interrupt voiding and hence estimate isovolumetric bladder pressure (p ves.isv . The validity, reliability, and clinical usefulness of the test were determined in a number of studies in men with LUTS. Results: The penile cuff test can be successfully performed in over 90% of men with LUTS. The reading of cuff pressure at flow interruption (p cuff.int gives a valid and reliable estimate of invasively-measured p ves.isv and when combined with the reading for maximum flow rate obtained during the test (Q max produces an accurate categorization of bladder outlet obstruction (BOO. Use of this categorization prior to treatment allows improved prediction of outcome from prostatectomy. Conclusion: The penile cuff test fulfils the criteria as a useful clinical measurement technique applicable to the diagnosis and treatment planning of men with LUTS.

  12. Comparing non-invasive scapular tracking methods across elevation angles, planes of elevation and humeral axial rotations.

    Science.gov (United States)

    Grewal, T-J; Cudlip, A C; Dickerson, C R

    2017-12-01

    Altered scapular motions premeditate shoulder impingement and other musculoskeletal disorders. Divergent experimental conditions in previous research precludes rigorous comparisons of non-invasive scapular tracking techniques. This study evaluated scapular orientation measurement methods across an expanded range of humeral postures. Scapular medial/lateral rotation, anterior/posterior tilt and protraction/retraction was measured using an acromion marker cluster (AMC), a scapular locator, and a reference stylus. Motion was captured using reflective markers on the upper body, as well as on the AMC, locator and stylus. A combination of 5 arm elevation angles, 3 arm elevation planes and 3 arm axial rotations was examined. Measurement method interacted with elevation angle and plane of elevation for all three scapular orientation directions (p planes and axial rotations. The AMC underestimated lateral rotation, with the largest difference of ∼2° at 0° elevation. Both the locator and AMC overestimated posterior tilt at high arm elevation by up to 7.4°. Misestimations from using the locator could be enough to potentially obscure meaningful differences in scapular rotations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Non-invasive mechanical ventilation and mortality in elderly immunocompromised patients hospitalized with pneumonia: a retrospective cohort study.

    Science.gov (United States)

    Johnson, Christopher S; Frei, Christopher R; Metersky, Mark L; Anzueto, Antonio R; Mortensen, Eric M

    2014-01-27

    Mortality after pneumonia in immunocompromised patients is higher than for immunocompetent patients. The use of non-invasive mechanical ventilation for patients with severe pneumonia may provide beneficial outcomes while circumventing potential complications associated with invasive mechanical ventilation. The aim of our study was to determine if the use of non-invasive mechanical ventilation in elderly immunocompromised patients with pneumonia is associated with higher all-cause mortality. In this retrospective cohort study, data were obtained from the Department of Veterans Affairs administrative databases. We included veterans age ≥65 years who were immunocompromised and hospitalized due to pneumonia. Multilevel logistic regression analysis was used to determine the relationship between the use of invasive versus non-invasive mechanical ventilation and 30-day and 90-day mortality. Of 1,946 patients in our cohort, 717 received non-invasive mechanical ventilation and 1,229 received invasive mechanical ventilation. There was no significant association between all-cause 30-day mortality and non-invasive versus invasive mechanical ventilation in our adjusted model (odds ratio (OR) 0.85, 95% confidence interval (CI) 0.66-1.10). However, those patients who received non-invasive mechanical ventilation had decreased 90-day mortality (OR 0.66, 95% CI 0.52-0.84). Additionally, receipt of guideline-concordant antibiotics in our immunocompromised cohort was significantly associated with decreased odds of 30-day mortality (OR 0.31, 95% CI 0.24-0.39) and 90-day mortality (OR 0.41, 95% CI 0.31-0.53). Our findings suggest that physicians should consider the use of non-invasive mechanical ventilation, when appropriate, for elderly immunocompromised patients hospitalized with pneumonia.

  14. Structured telephone support or non-invasive telemonitoring for patients with heart failure.

    Science.gov (United States)

    Inglis, Sally C; Clark, Robyn A; Dierckx, Riet; Prieto-Merino, David; Cleland, John G F

    2015-10-31

    Specialised disease management programmes for heart failure aim to improve care, clinical outcomes and/or reduce healthcare utilisation. Since the last version of this review in 2010, several new trials of structured telephone support and non-invasive home telemonitoring have been published which have raised questions about their effectiveness. To review randomised controlled trials (RCTs) of structured telephone support or non-invasive home telemonitoring compared to standard practice for people with heart failure, in order to quantify the effects of these interventions over and above usual care. We updated the searches of the Cochrane Central Register of Controlled Trials (CENTRAL), Database of Abstracts of Reviews of Effects (DARE), Health Technology AsseFssment Database (HTA) on the Cochrane Library; MEDLINE (OVID), EMBASE (OVID), CINAHL (EBSCO), Science Citation Index Expanded (SCI-EXPANDED), Conference Proceedings Citation Index- Science (CPCI-S) on Web of Science (Thomson Reuters), AMED, Proquest Theses and Dissertations, IEEE Xplore and TROVE in January 2015. We handsearched bibliographies of relevant studies and systematic reviews and abstract conference proceedings. We applied no language limits. We included only peer-reviewed, published RCTs comparing structured telephone support or non-invasive home telemonitoring to usual care of people with chronic heart failure. The intervention or usual care could not include protocol-driven home visits or more intensive than usual (typically four to six weeks) clinic follow-up. We present data as risk ratios (RRs) with 95% confidence intervals (CIs). Primary outcomes included all-cause mortality, all-cause and heart failure-related hospitalisations, which we analysed using a fixed-effect model. Other outcomes included length of stay, health-related quality of life, heart failure knowledge and self care, acceptability and cost; we described and tabulated these. We performed meta-regression to assess homogeneity (the

  15. Non-invasive measurements of exhaled NO and CO associated with methacholine responses in mice

    Directory of Open Access Journals (Sweden)

    Ameredes Bill T

    2008-05-01

    Full Text Available Abstract Background Nitric oxide (NO and carbon monoxide (CO in exhaled breath are considered obtainable biomarkers of physiologic mechanisms. Therefore, obtaining their measures simply, non-invasively, and repeatedly, is of interest, and was the purpose of the current study. Methods Expired NO (ENO and CO (ECO were measured non-invasively using a gas micro-analyzer on several strains of mice (C57Bl6, IL-10-/-, A/J, MKK3-/-, JNK1-/-, NOS-2-/- and NOS-3-/- with and without allergic airway inflammation (AI induced by ovalbumin systemic sensitization and aerosol challenge, compared using independent-sample t-tests between groups, and repeated measures analysis of variance (ANOVA within groups over time of inflammation induction. ENO and ECO were also measured in C57Bl6 and IL-10-/- mice, ages 8–58 weeks old, the relationship of which was determined by regression analysis. S-methionyl-L-thiocitrulline (SMTC, and tin protoporphyrin (SnPP were used to inhibit neuronal/constitutive NOS-1 and heme-oxygenase, respectively, and alter NO and CO production, respectively, as assessed by paired t-tests. Methacholine-associated airway responses (AR were measured by the enhanced pause method, with comparisons by repeated measures ANOVA and post-hoc testing. Results ENO was significantly elevated in naïve IL-10-/- (9–14 ppb and NOS-2-/- (16 ppb mice as compared to others (average: 5–8 ppb, whereas ECO was significantly higher in naïve A/J, NOS-3-/- (3–4 ppm, and MKK3-/- (4–5 ppm mice, as compared to others (average: 2.5 ppm. As compared to C57Bl6 mice, AR of IL-10-/-, JNK1-/-, NOS-2-/-, and NOS-3-/- mice were decreased, whereas they were greater for A/J and MKK3-/- mice. SMTC significantly decreased ENO by ~30%, but did not change AR in NOS-2-/- mice. SnPP reduced ECO in C57Bl6 and IL-10-/- mice, and increased AR in NOS-2-/- mice. ENO decreased as a function of age in IL-10-/- mice, remaining unchanged in C57Bl6 mice. Conclusion These results are

  16. Non-invasive evaluation of physiological stress in an iconic Australian marsupial: the Koala (Phascolarctos cinereus).

    Science.gov (United States)

    Narayan, Edward J; Webster, Koa; Nicolson, Vere; Mucci, Al; Hero, Jean-Marc

    2013-06-15

    Koalas (Phascolarctos cinereus) are the only extant representatives of Australia's unique marsupial family Phascolarctidae and were listed as nationally Vulnerable in 2012. Causes of mortality are diverse, although the disease chlamydiosis, dog attacks, collisions with cars, and loss of habitat represent the principal reasons for the continued species decline. Koala breeding facilities in Queensland and New South Wales, Australia have been established for conservation and tourism. Non-invasive monitoring of physiological stress is important for determining the sub-lethal effects of environmental stressors on the well-being, reproduction and survival of Koalas in Zoos and also in the wild. In this study, we developed a faecal cortisol metabolite (FCM) enzyme-immunoassay (EIA) for monitoring physiological stress in Koalas from two established Zoos in Australia and also within a free-living sub-population from Queensland. Biological validation of the FCM EIA was done using an adrenocorticotropic hormone (ACTH) challenge. We discovered excretory lag-times of FCM of 24 h in females (n=2) and 48 h in male (n=2) Koalas in response to the ACTH challenge. FCM levels showed an episodic and delayed peak response lasting up to 9 days post ACTH challenge. This finding should be taken into consideration when designing future experiments to study the impacts of short-term (acute) and chronic stressors on the Koalas. Laboratory validations were done using parallelism and recovery checks (extraction efficiency) of the cortisol standard against pooled Koala faecal extracts. Greater than 99% recovery of the cortisol standard was obtained as well as a parallel displacement curve against Koala faecal extracts. FCM levels of the captive Koalas (n=10 males and 13 females) significantly differed by sex, reproductive condition (lactating versus non-lactating Koalas) and the handling groups. Handled male Koalas had 200% higher FCM levels than their non-handled counterparts, while females

  17. Utility and reliability of non-invasive muscle function tests in high-fat-fed mice.

    Science.gov (United States)

    Martinez-Huenchullan, Sergio F; McLennan, Susan V; Ban, Linda A; Morsch, Marco; Twigg, Stephen M; Tam, Charmaine S

    2017-07-01

    What is the central question of this study? Non-invasive muscle function tests have not been validated for use in the study of muscle performance in high-fat-fed mice. What is the main finding and its importance? This study shows that grip strength, hang wire and four-limb hanging tests are able to discriminate the muscle performance between chow-fed and high-fat-fed mice at different time points, with grip strength being reliable after 5, 10 and 20 weeks of dietary intervention. Non-invasive tests are commonly used for assessing muscle function in animal models. The value of these tests in obesity, a condition where muscle strength is reduced, is unclear. We investigated the utility of three non-invasive muscle function tests, namely grip strength (GS), hang wire (HW) and four-limb hanging (FLH), in C57BL/6 mice fed chow (chow group, n = 48) or a high-fat diet (HFD group, n = 48) for 20 weeks. Muscle function tests were performed at 5, 10 and 20 weeks. After 10 and 20 weeks, HFD mice had significantly reduced GS (in newtons; mean ± SD: 10 weeks chow, 1.89 ± 0.1 and HFD, 1.79 ± 0.1; 20 weeks chow, 1.99 ± 0.1 and HFD, 1.75 ± 0.1), FLH [in seconds per gram body weight; median (interquartile range): 10 weeks chow, 2552 (1337-4964) and HFD, 1230 (749-1994); 20 weeks chow, 2048 (765-3864) and HFD, 1036 (717-1855)] and HW reaches [n; median (interquartile range): 10 weeks chow, 4 (2-5) and HFD, 2 (1-3); 20 weeks chow, 3 (1-5) and HFD, 1 (0-2)] and higher falls [n; median (interquartile range): 10 weeks chow, 0 (0-2) and HFD, 3 (1-7); 20 weeks chow, 1 (0-4) and HFD, 8 (5-10)]. Grip strength was reliable in both dietary groups [intraclass correlation coefficient (ICC) = 0.5-0.8; P tests are valuable and reliable tools for assessment of muscle strength and function in high-fat-fed mice. © 2017 The Authors. Experimental Physiology © 2017 The Physiological Society.

  18. Raman spectroscopy technology to monitor the carotenoids in skin of thalassemia patients: a novel non-invasive tool relating oxidative stress with iron burden

    Directory of Open Access Journals (Sweden)

    Anna Perrone

    2014-09-01

    Full Text Available In this work we approach the relationship between redox state and iron overload by noninvasive instrumental techniques. Intracardiac, liver iron and liver fibrosis have been monitored in transfusion-dependent thalassemia patients by magnetic resonance imaging and hepatic transient elastography examinations. These measurements have been matched with a non-invasive, and yet unexplored in clinical practice, evaluation of body’s oxidative stress through measurement of antioxidant carotenoids in skin, by a spectroscopic method based on Raman technology (RRS. The global body’s antioxidant status results from a balance between the level of antioxidants in cells and body fluids, including blood, and pro-oxidant species endogenously produced or coming from external sources. On this basis, the level of skin carotenoids can be considered a biomarker of the entire antioxidant status. In our work the use of RRS method provided information on the redox state of thalassemia patients, which was correlated with the iron status of the patients. Due to the highly adverse effects of accumulated iron, the novel, simple, non-invasive RRS to monitor dermal carotenoids with high compliance of the patients may be a useful tool for the management of thalassemia patients.

  19. Utility of spatial frequency domain imaging (SFDI) and laser speckle imaging (LSI) to non-invasively diagnose burn depth in a porcine model☆

    Science.gov (United States)

    Burmeister, David M.; Ponticorvo, Adrien; Yang, Bruce; Becerra, Sandra C.; Choi, Bernard; Durkin, Anthony J.; Christy, Robert J.

    2015-01-01

    Surgical intervention of second degree burns is often delayed because of the difficulty in visual diagnosis, which increases the risk of scarring and infection. Non-invasive metrics have shown promise in accurately assessing burn depth. Here, we examine the use of spatial frequency domain imaging (SFDI) and laser speckle imaging (LSI) for predicting burn depth. Contact burn wounds of increasing severity were created on the dorsum of a Yorkshire pig, and wounds were imaged with SFDI/LSI starting immediately after-burn and then daily for the next 4 days. In addition, on each day the burn wounds were biopsied for histological analysis of burn depth, defined by collagen coagulation, apoptosis, and adnexal/vascular necrosis. Histological results show that collagen coagulation progressed from day 0 to day 1, and then stabilized. Results of burn wound imaging using non-invasive techniques were able to produce metrics that correlate to different predictors of burn depth. Collagen coagulation and apoptosis correlated with SFDI scattering coefficient parameter ( μs′) and adnexal/vascular necrosis on the day of burn correlated with blood flow determined by LSI. Therefore, incorporation of SFDI scattering coefficient and blood flow determined by LSI may provide an algorithm for accurate assessment of the severity of burn wounds in real time. PMID:26138371

  20. A face in the crowd: a non-invasive and cost effective photo-identification methodology to understand the fine scale movement of eastern water dragons.

    Directory of Open Access Journals (Sweden)

    Riana Zanarivero Gardiner

    Full Text Available Ectothermic vertebrates face many challenges of thermoregulation. Many species rely on behavioral thermoregulation and move within their landscape to maintain homeostasis. Understanding the fine-scale nature of this regulation through tracking techniques can provide a better understanding of the relationships between such species and their dynamic environments. The use of animal tracking and telemetry technology has allowed the extensive collection of such data which has enabled us to better understand the ways animals move within their landscape. However, such technologies do not come without certain costs: they are generally invasive, relatively expensive, can be too heavy for small sized animals and unreliable in certain habitats. This study provides a cost-effective and non-invasive method through photo-identification, to determine fine scale movements of individuals. With our methodology, we have been able to find that male eastern water dragons (Intellagama leuseurii have home ranges one and a half times larger than those of females. Furthermore, we found intraspecific differences in the size of home ranges depending on the time of the day. Lastly, we found that location mostly influenced females' home ranges, but not males and discuss why this may be so. Overall, we provide valuable information regarding the ecology of the eastern water dragon, but most importantly demonstrate that non-invasive photo-identification can be successfully applied to the study of reptiles.